WorldWideScience

Sample records for selective renal angiography

  1. Renal haemodynamic in essential hypertension assessed by 133Xe washout and selective renal angiography

    International Nuclear Information System (INIS)

    Gatta, A.; Merkel, C.; Pessina, A.C.; Milani, L.; Sacerdoti, D.; Zuin, R.

    1982-01-01

    The renal and intrarenal haemodynamic pattern in 17 patients with essential hypertension of different severity and duration was studied by means of the 133-Xenon washout technique and the selective renal angiography. The mean and the cortical renal blood flows were on average significantly decreased as compared to the controls. A good agreement was found between the reduction in renal perfusion and the degree of vascular abnormalities as shown by angiography; on the contrary no correlation was found between the impairment in renal blood flow and the degree and/or duration of hypertension

  2. Metrizamide in experimental selective renal angiography

    International Nuclear Information System (INIS)

    Pokorny, L.; Kelemen, J.

    1981-01-01

    Forty-seven dogs or seventy-four kidneys, respectively, were used in studies into the activity of metrizamide (Amipaque). The angiograms were of good quality; as compared with contrast media tested before, the incidence of abnormalities was somewhat lower, and the symptoms (spasm, inhomogeneous nephrogram) were less important. Histological examination showed that plenty of homogeneous pink proteinlike substance had accumulated in many tubules as well as in the lumen of the Bowman's capsules; fibroses were seen in several parts after 7 and 28 days, respectively. However, the evaluation of the renal function showed no considerable changes in the laboratory values. (orig.) [de

  3. Angiography in renal tuberculosis

    Energy Technology Data Exchange (ETDEWEB)

    Choi, Doo Suk [Seoul National University College of Medicine, Seoul (Korea, Republic of)

    1974-10-15

    Angiographies on forty cases of renal tuberculosis performed at the National Medical Center during a period 1960 through 1970 were reviewed. Abdominal angiography was performed via the femoral route. Some were followed by selective nephroangiography. All patients were subjected to urographyior to angiography. The results of X-ray findings in the forty cases with renal tuberculosis were follows. 1. The age varied 18 to 57 years, average 30.5 years. Twenty one patients were male, and nineteen were female. 2. The right kidney was involved in 17 cases and the left in 15 cases. Both kidneys were involved in 8 cases. 3. Urographic examination revealed pathologic changes in all patients. 4. Focal destruction in the collecting system was the most common finding in the urography of 16 patients. 5. A varying degree of hydronephrosis was present in 15 patients, of whom nine had complained of palpable mass due to hydronephrosis. 6. In the 7 patients with extensive destruction there was no observable excretion contrast medium from the diseased kidney. 7. Angiographic examination was normal in 6 of the 40 patients. 8. Decreased vascularity in the subsegmental or smaller arteries of the affected kidney was the most frequent finding, being found in 34 patients. 9. Occlusion or abrupt termination of the subsegmental arteries was present in 4 patients. 10. Eighteen of the patients had signs of an expansive process within the cavity, the vessels being displaced and stretched around the lesions.

  4. Renal artery anatomy assessed by quantitative analysis of selective renal angiography in 1,000 patients with hypertension.

    Science.gov (United States)

    Lauder, Lucas; Ewen, Sebastian; Tzafriri, Abraham Rami; Edelman, Elazer Reuven; Lüscher, Thomas Felix; Blankenstijn, Peter J; Dörr, Oliver; Schlaich, Markus; Sharif, Faisal; Voskuil, Michiel; Zeller, Thomas; Ukena, Christian; Scheller, Bruno; Böhm, Michael; Mahfoud, Felix

    2018-05-20

    With increasing attention to renovascular causes and targets for hypertension there arises a critical need for more detailed knowledge of renal arterial anatomy. However, a standardised nomenclature is lacking. The present study sought to develop a standardised nomenclature for renal anatomy considering the complexity and variation of the renal arterial tree and to assess the applicability of the nomenclature. One thousand hypertensive patients underwent invasive selective renal artery angiography in nine centres. Further, renovasography was performed in 249 healthy swine as a surrogate for normotensive anatomy. Anatomical parameters were assessed by quantitative vascular analysis. Patients' mean blood pressure was 168/90±26/17 mmHg. The right main renal artery was longer than the left (41±15 mm vs. 35±13 mm, prenal arteries and renal artery disease were documented in 22% and 9% of the patients, respectively. Other than exhibiting a longer left main renal artery in uncontrolled hypertensives (+2.7 mm, p=0.034) there was no anatomical difference between patients with controlled and uncontrolled hypertension. Main renal artery mean diameter was smaller in patients with impaired kidney function (GFR Renal arterial anatomy differs between sides but shows no difference between patients with and without blood pressure control. Impaired GFR was associated with small main renal artery diameter.

  5. The affects of contrast medium on renal function in selective coronary angiography and intervention

    International Nuclear Information System (INIS)

    Chen Yueguang; Lv Baojing

    2006-01-01

    Selective coronary angiography and intervention with injection of contrast medium into the coronary arteries has become very common in dealing with coronary cardiac diseases. The excretion of contrast medium through kidneys may lead to acute renal functional insufficiency, especially for those suffering from chronic nephropathy, diabetes and cardiac functional disorder to form the so called 'contrast medium nephropathy' which is considered as the number second drug induced acute renal functional failure. Although routine preventive measure including low osmotic contrast medium and fine hydrotherapy have been taken, 14% incidences still occur with renal functional damage. The majority could be reversible but the minority needs emergent hemodialysis or even with persistent renal functional damage in a few ones. (authors)

  6. Can selective pharmaco-angiography of renal tumor replace the examination under surgery?

    International Nuclear Information System (INIS)

    Will, C.H.; Bach, D.; Koop, H.; Impekoven, P.

    1996-01-01

    Can primary nephrectomy be performed without preliminary sample excision of the tumor if pharmaco-angiography of the kidney has demonstrated the typical tumor vascularization? To clarify this question in 32 patients with 'displacing mass' of the kidney, verified in sonography and computer-tomography, or hematuria of unknown origin, we prospectively performed an additional pharmaco-angiography of the respective kidney. In 18 patients with tumor vascularization in the pharmaco-angiography, intraoperatively we found 15 malignant renal cell carcinomas, 1 patient with transitional cell carcinoma of the renal pelvis, 1 leiomyosarcoma, and 1 high-differentiated tumor of only 2 cm in diameter with unclear dignity, which was treated by enucleation. In cases of an intrarenal lesion of more than 3 cm in diameter and additional tumor vascularization seen in selective pharmaco-angiography, the kidney undoubtedly can be removed by primary nephrectomy without a preliminary sample excision to confirm the diagnosis. For tumors with a diameter of less than 3 cm and additional tumor-vascularization, the option should be enucleation. If there is a 'tumor' without typical malignant vascularization, the exploration by sample excision should be performed. Depending on the histological result the tumor should be removed by enucleation or nephrectomy. (orig.) [de

  7. Angiography for renal hypertension

    International Nuclear Information System (INIS)

    Chuang, V.P.; Ernst, C.B.

    1985-01-01

    As angioplasty and operative techniques have become more precise and successful, so have evaluation techniques. Preoperative arteriography is indispensible for deciding on the appropriate treatment modality and the specifics of the procedure. Arteriography, therefore, remains the cornerstone in managing renovascular hypertension and renal arterial disease

  8. Renal computed angiography. Part I: Renal CT arteriography in hypertension

    International Nuclear Information System (INIS)

    Al-Amin, M.; Hadjidekov, V.

    2012-01-01

    Visualization of renal vasculature is needed in several clinical condition among which hypertension is dominant. CT angiography now day replaces catheter angiography as non-invasive method. The goal of this study is to present initial authors experience in visualization of renal arteries using 64 MDCT and to evaluated the utility in hypertensive patients. MDCT assures excellent assessment of renal arteries conditions. Multiplanar reconstruction and allow better delineation in tortuous vessels course and anatomic variants. (authors)

  9. Risk of renal allograft rejection following angiography

    International Nuclear Information System (INIS)

    Heideman, M.; Claes, G.; Nilson, A.E.

    1976-01-01

    In a retrospective study of 173 immediately functioning primary kidney transplants, correlation between angiography and renal allograft rejection was studied during the first 14 days. It was found that rejection was more frequent in kidneys undergoing angiography than in those not undergoing angiography. It was also found that in kidneys undergoing angiography an overwhelming number of the rejections started the day after angiography. These differences in rejection frequency could not be explained by differences in HLA matching or the origin of the kidneys. These findings suggest a possible connection indicating that the angiography might elicit an acute rejection episode. A possible mechanism for starting this reaction might be activation of the complement system which was found in 50 percent of the patients undergoing angiography in peripheral blood and in 100 percent when studied in vitro

  10. Usefulness of MR angiography in renal tumor

    International Nuclear Information System (INIS)

    Oka, Toshitsugu; Morimoto, Kouji; Nishimura, Kenji; Tsujimura, Akira; Yasunaga, Yutaka; Matsumiya, Kiyomi; Takaha, Minato

    1992-01-01

    MR angiography using a gradient-echo, pulse sequence FLASH (fast, low-angle shot) method during breath-hold with a 'MAGNETOM H-15' scanner (1.5 Tesla; Siemens Medical System) was performed on 27 patients with renal tumor at our clinic between Feburary 20, 1990 and September 30, 1991 and we studied to evaluate its usefulness. Of these 27 patients, 22 patients including one patient under hemodialysis treatment had renal cell carcinoma and one patient had oncocytoma pathologically proven from the excised specimens. The remaining four patients including two patients associated with inferior vena cava tumor thrombus were clinically diagnosed as renal cell carcinoma based on the result of imaging examinations such as excretory urography, ultrasonography, computed tomography and conventional angiography. However, they could not be operated on because their tumors were too advanced. By reconstruction of the data of consecutive coronal scans of the abdominal blood vessels such as the abdominal aorta, inferior vena cava and renal arteries and veins simultaneously without any intravenous contrast materials. Our present study revealed that MR angiography has some advantages, especially with regard to preoperative angiographic information about the abdomen of patients with renal tumor. That is, MR angiography can delineate many kinds of arteries and veins of the abdomen simultaneously and in a broader range, as well as it can be performed on the patients with hypersensitivity to iodinate contrast materials or renal insufficiency in a usual fashion. Furthermore, our present study suggested that the MR angiography is useful for assessing the presence and extent of inferior vena caval tumor thrombus of renal cell carcinoma and for clearly distinguishing tumor lesion and the surrounding normal renal parenchyma in the patients with renal tumor. (author)

  11. Usefulness of MR angiography in renal tumor

    Energy Technology Data Exchange (ETDEWEB)

    Oka, Toshitsugu; Morimoto, Kouji; Nishimura, Kenji; Tsujimura, Akira; Yasunaga, Yutaka; Matsumiya, Kiyomi; Takaha, Minato (Osaka National Hospital (Japan))

    1992-11-01

    MR angiography using a gradient-echo, pulse sequence FLASH (fast, low-angle shot) method during breath-hold with a MAGNETOM H-15 scanner (1.5 Tesla; Siemens Medical System) was performed on 27 patients with renal tumor at our clinic between Feburary 20, 1990 and September 30, 1991 and we studied to evaluate its usefulness. Of these 27 patients, 22 patients including one patient under hemodialysis treatment had renal cell carcinoma and one patient had oncocytoma pathologically proven from the excised specimens. The remaining four patients including two patients associated with inferior vena cava tumor thrombus were clinically diagnosed as renal cell carcinoma based on the result of imaging examinations such as excretory urography, ultrasonography, computed tomography and conventional angiography. However, they could not be operated on because their tumors were too advanced. By reconstruction of the data of consecutive coronal scans of the abdominal blood vessels such as the abdominal aorta, inferior vena cava and renal arteries and veins simultaneously without any intravenous contrast materials. Our present study revealed that MR angiography has some advantages, especially with regard to preoperative angiographic information about the abdomen of patients with renal tumor. That is, MR angiography can delineate many kinds of arteries and veins of the abdomen simultaneously and in a broader range, as well as it can be performed on the patients with hypersensitivity to iodinate contrast materials or renal insufficiency in a usual fashion. Furthermore, our present study suggested that the MR angiography is useful for assessing the presence and extent of inferior vena caval tumor thrombus of renal cell carcinoma and for clearly distinguishing tumor lesion and the surrounding normal renal parenchyma in the patients with renal tumor. (author).

  12. Spiral CT angiography of renal arteries: comparison with angiography

    International Nuclear Information System (INIS)

    Wittenberg, G.; Kenn, W.; Tschammler, A.; Sandstede, J.; Hahn, D.

    1999-01-01

    A prospective study was carried out to determine the accuracy of spiral CT angiography (CTA) in the detection of renal artery stenosis (RAS). Eighty-two patients with arterial hypertension underwent CTA and digital subtraction angiography (DSA) to exclude RAS. For CTA a contrast medium bolus of 100-150 ml (flow rate 3 ml/s) was injected. A 24 or 40 s CTA was started at the origin of the superior mesenteric artery after a delay time determined by test bolus injection (collimation = 2 mm, pitch = 1/1.5). For stenosis detection transverse images supported by maximum intensity projections (MIP) or multiplanar reconstruction projections were used. Of 197 renal arteries examined (including 33 accessory arteries), 34 RAS were visualized using DSA. With CTA, one hemodynamic RAS was missed and one additional hemodynamic RAS was found. Sensitivity/specificity was calculated to be 94 %/98 %. For hemodynamically relevant RAS (> 50 %) the sensitivity/specificity was 96 %/99 %. CTA additionally depicted five adrenal masses. The high accuracy rate of RAS detection thus allows the use of CTA as a screening method in patients with arterial hypertension to exclude a renovascular cause. (orig.)

  13. MR angiography of in situ and transplanted renal arteries

    International Nuclear Information System (INIS)

    Smith, H.J.; Bakke, S.J.

    1993-01-01

    Three-dimensional (3D) time-of-flight (TOF) MR angiography (MRA) was performed in 34 patients with suspected renal artery disease. In situ (i.e., nontransplanted) renal arteries were studied with MRA in 14 patients. Of these, 12 had conventional angiography for comparison. Twenty-four MRAs of transplanted renal arteries were obtained in 20 patients; 8 of these had angiography as well. Significant stenoses of in situ renal arteries were diagnosed with a sensitivity of 100% and a specificity of 95%. The stenoses were all proximal; 3D TOF MRA proved inadequate for depiction of peripheral renal arteries. MRA and angiography showed good agreement between findings in 7 of 8 patients with renal transplants. In one patient with a renal transplant, MRA showed a significant stenosis of the arterial anastomosis which appeared completely normal at i.a. DSA, indicating that findings at MRA still need to be confirmed by more established alternative methods. (orig.)

  14. Conventional renal angiography versus renal digital subtraction angiography (DSA) in the study of renovascular hypertension

    International Nuclear Information System (INIS)

    Essinger, A.; Morsier, B. de; Narbel, M.; Raimondi, S.

    1988-01-01

    A cost-benefit analysis comparing conventional renal angiography, IV and IA DSA and spot film cameras has been made in order to quantify the advantages and disadvantages of these techniques in screening for renal artery stenosis. DSA is the best modality of imaging, using very little films, easy to archive, with a spatial resolution inferior to conventional angiography but partially compensated by contrast resolution. The surface dose per image using a 512/512 matrix is two thirds less than a conventional film, giving thus an acceptable dose as long as technical personnel is well trained and thus the number of exposures is kept low. Spot film camera, due to its excellent spatial resolution, its low radiation dose and its low price, can also be used as a screening procedure but requires an arterial injection. DSA has furthermore the advantage of quantifying renal artery stenosis making future percutaneous transluminal angioplasty easier

  15. Use of digital subtraction angiography for renal transplant evaluation

    International Nuclear Information System (INIS)

    Fanucci, E.; Orlacchio, A.; Pocek, M.; Svegliati, F.

    1986-01-01

    Intravenous digital subtraction angiography (IVDSA) was used to evaluate 6 renal allograft recipients and 3 potential renal donors. In 4 potential renal donors and in 2 allograft recipients, angiographic data were confirmed by surgery. IVDSA is a safe, accurate, easily performed, outpatient procedure; in our opinion DSA should became the procedure of choice to study vascular anatomy in renal transplant evaluation

  16. Stent sizing strategies in renal artery stenting: the comparison of conventional invasive renal angiography with renal computed tomographic angiography.

    Science.gov (United States)

    Kadziela, Jacek; Michalowska, Ilona; Pregowski, Jerzy; Janaszek-Sitkowska, Hanna; Lech, Katarzyna; Kabat, Marek; Staruch, Adam; Januszewicz, Andrzej; Witkowski, Adam

    2016-01-01

    Randomized trials comparing invasive treatment of renal artery stenosis with standard pharmacotherapy did not show substantial benefit from revascularization. One of the potential reasons for that may be suboptimal procedure technique. To compare renal stent sizing using two modalities: three-dimensional renal computed tomography angiography (CTA) versus conventional angiography. Forty patients (41 renal arteries), aged 65.1 ±8.5 years, who underwent renal artery stenting with preprocedural CTA performed within 6 months, were retrospectively analyzed. In CTA analysis, reference diameter (CTA-D) and lesion length (CTA_LL) were measured and proposed stent diameter and length were recorded. Similarly, angiographic reference diameter (ANGIO_D) and lesion length (ANGIO_LL) as well as proposed stent dimensions were obtained by visual estimation. The median CTA_D was 0.5 mm larger than the median ANGIO_D (p < 0.001). Also, the proposed stent diameter in CTA evaluation was 0.5 mm larger than that in angiography (p < 0.0001). The median CTA_LL was 1 mm longer than the ANGIO_LL (p = NS), with significant correlation of these variables (r = 0.66, p < 0.0001). The median proposed stent length with CTA was equal to that proposed with angiography. The median diameter of the implanted stent was 0.5 mm smaller than that proposed in CTA (p < 0.0005) and identical to that proposed in angiography. The median length of the actual stent was longer than that proposed in angiography (p = 0.0001). Renal CTA has potential advantages as a tool adjunctive to angiography in appropriate stent sizing. Careful evaluation of the available CTA scans may be beneficial and should be considered prior to the planned procedure.

  17. Renal computed angiography. Part I: Renal CT phlebography. Renal veins variants

    International Nuclear Information System (INIS)

    Al-Amin, M.; Krupev, M.; Hadjidekov, V.; Plachkov, I.

    2012-01-01

    The changing trend in renal surgery, transplantation and minimal invasive urology implies preprocedure evaluation of renal veins. Development of imaging methods offers new possibilities for venographic visualization. The goal of this study is to present authors experience in visualization of renal veins using 64 MDCT and to evaluate the utility in assessments of their variants. 128 patients (68 females and 60 males, mean age 53,3) with urological complaints underwent 64MDCT examination including CT angiography. Contrast enhancement includes 3-4ml/sec injection flow of 90 ml contrast medium followed by 20 ml saline at the same rate. In 23 out of 128 examined patients some of the common variants of the renal vein is found. 64 MDCT angiography visualize very well renal veins and becomes method of choice in preoperative assessment of renal vein anatomy. (authors)

  18. Multidetector CT angiography of renal vasculature: normal anatomy and variants

    International Nuclear Information System (INIS)

    Tuerkvatan, Aysel; Oezdemir, Mustafa; Cumhur, Turhan; Oelcer, Tuelay

    2009-01-01

    Knowledge of the variations in renal vascular anatomy is important before laparoscopic donor or partial nephrectomy and vascular reconstruction for renal artery stenosis or abdominal aortic aneurysm. Recently, multidetector computed tomographic (MDCT) angiography has become a principal imaging investigation for assessment of the renal vasculature and has challenged the role of conventional angiography. It is an excellent imaging technique because it is a fast and non-invasive tool that provides highly accurate and detailed evaluation of normal renal vascular anatomy and variants. The number, size and course of the renal arteries and veins are easily identified by MDCT angiography. The purpose of this pictorial essay is to illustrate MDCT angiographic appearance of normal anatomy and common variants of the renal vasculature. (orig.)

  19. Multidetector CT angiography of renal vasculature: normal anatomy and variants

    Energy Technology Data Exchange (ETDEWEB)

    Tuerkvatan, Aysel; Oezdemir, Mustafa; Cumhur, Turhan; Oelcer, Tuelay [Tuerkiye Yueksek ihtisas Hospital, Department of Radiology, Sihhiye, Ankara (Turkey)

    2009-01-15

    Knowledge of the variations in renal vascular anatomy is important before laparoscopic donor or partial nephrectomy and vascular reconstruction for renal artery stenosis or abdominal aortic aneurysm. Recently, multidetector computed tomographic (MDCT) angiography has become a principal imaging investigation for assessment of the renal vasculature and has challenged the role of conventional angiography. It is an excellent imaging technique because it is a fast and non-invasive tool that provides highly accurate and detailed evaluation of normal renal vascular anatomy and variants. The number, size and course of the renal arteries and veins are easily identified by MDCT angiography. The purpose of this pictorial essay is to illustrate MDCT angiographic appearance of normal anatomy and common variants of the renal vasculature. (orig.)

  20. Non-enhanced ECG-gated respiratory-triggered 3-D steady-state free-precession MR angiography with slab-selective inversion: initial experience in visualisation of renal arteries in free-breathing children without renal artery abnormality

    International Nuclear Information System (INIS)

    Klee, Dirk; Lanzman, Rotem Shlomo; Blondin, Dirk; Antoch, Gerald; Schaper, Joerg; Schmitt, Peter; Oh, Jun; Salgin, Burak; Mayatepek, Ertan

    2012-01-01

    ECG-gated non-enhanced balanced steady-state free precession (bSSFP) MR angiography requires neither breath-holding nor administration of contrast material. To investigate the image quality of free-breathing ECG-gated non-enhanced bSSFP MR angiography of renal arteries in children. Fourteen boys and seven girls (mean age, 9.7 years; range, 7 weeks-17 years) with no history of renovascular disease were included. MRI was performed at 1.5 T. Subjective image quality of axial and coronal maximum-intensity-projection reconstructions of four segments (I, aorta and renal artery ostium; II, main renal artery; III, segmental branches; IV, intrarenal vessels) was evaluated using a 4-point scale (4 = excellent, 3 = good, 2 = acceptable, 1 = non-diagnostic). Image quality was excellent for segments I (mean ± SD, 3.9 ± 0.3) and II (4.0 ± 0.1), good for segment III (3.4 ± 0.9) and acceptable for segment IV (2.3 ± 1.1). Mean image quality did not differ between sedated and non-sedated children. bSSFP MR angiography enables visualisation of renal arteries in children. (orig.)

  1. Experimental studies of renal blood flow by digitized functional angiography

    International Nuclear Information System (INIS)

    Buersch, J.H.; Ochs, C.; Hahne, H.J.; Heintzen, P.H.

    1985-01-01

    New techniques of digital image processing have been experimentally tested for the assessment of renal blood flow. The underlying principle in functional angiography is the extraction of flow parameters. Basically, density-time variations of the contrast medium are analayzed from to each picture element of a 256x256 matrix. The real-time acquisition rate of images was 25/sec. For the calculation of angiographic flow a PDP 11/40 computer was used to interactively perform a time dependent segmentation of the renal arteries and the aorta. Subsequently, volume flow was calculated in relative units for the specific vascular segments under study. 15 control angiograms were made in 5 animals with cardiac output ranging between 0.8 to 2.2l/min. Unilateral renal blood flow was calculated as 24+-3.4% of pre-renal aortic flow without systematic side differences. Reproducibility from repeated flow measurements showed an SD of +-1.8% of the individual pre-renal aortic flow. Renal flow was also measured in 3 animals with an experimentally created 50% flow reduction of the left kidney. Angiographic flow in the left renal artery dropped to 12+-2% of pre-renal flow. The present experimental data suggest that digital angiography has sufficient diagnostic capabilities for the detection of abnormal renal blood flow. The technique may serve as a useful diagnostic adjunct to conventional angiography and has the potential of assisting in the evaluation of renal vascular hypertension. (orig.) [de

  2. Comparison of spiral CT angiography with conventional digital subtraction angiography in the evaluation of renal transplant donors: a pilot study

    International Nuclear Information System (INIS)

    Chu, C.; Young, N.; Lau, H.

    2001-01-01

    Conventional digital subtraction renal arteriography (IA-DSA) has been traditionally used as the preoperative imaging modality for assessment of renal vascular anatomy for renal transplant donors. This study evaluates the potential use of spiral CT angiography in replacing IA-DSA in the preoperative assessment of this group of patients. Seven patients underwent both spiral CT angiography and IA-DSA between October 1997 and April 1998. It is concluded that spiral CT angiography can demonstrate the number, length and location of renal arteries and it is suggested that spiral CT angiography can potentially replace IA-DSA in the preoperative assessment of renal donors. Copyright (2001) Blackwell Science Pty Ltd

  3. Effective selection of hypertensive patients for angiography

    International Nuclear Information System (INIS)

    van der Voorde, F.; Derkx, F.H.M.; Bossuyt, P.M.M.; Segaar, R.W.; de Wind, A.; Pieterman, H.

    1989-01-01

    The authors prospectively observed 373 severe hypertensives with either diastolic blood pressure (BP) ≥ 105 and age ≤ 40, or BP with three drugs ≥ 105 (regardless of age). Excluded were patients who were older than 75 or who had creatinine >400. History, physical examination, and laboratory data were used to identify high-yield criteria for arteriography. All patients underwent angiography as the gold standard; angiography showed 127 unilateral renal artery stenoses, 73 bilateral renal artery stenoses, and 173 (nonstenosed) essential hypertensives. The authors constructed a logistic regression model of height, weight, age, smoking, and hypertension duration, which could be used to identify 90% of stenosed patients with 50% fewer angiographies in the essential hypertensives

  4. Digital subtraction angiography in 105 living renal transplant donors

    International Nuclear Information System (INIS)

    Suh, Ho Jong; Oh, Kyung Seung; Kim, So Sun; Huh, Jin Do; Kim, Ho Joon; Chun, Byung Hee; Joh, Young Duck

    1989-01-01

    In order to analyze the number and length of the renal arteries and to evaluate abnormalities of the renal parenchyma and vessel, digital subtraction angiogram images of 105 potential renal donors (45 men and 60 women aged 17-66 years) were studied retrospectively. For the entire series, 31 donors had multiple renal arteries on one side (15 on the left, 11 on the right) and 5 donors on the both sides. 89 donors were family related either parents or siblings of recipients. The estimation of the length of the renal artery was based on the mean height of the second lumbar vertebral body (L2). The right renal artery is significant longer than on the left and measured more than the height of L2 vertebral body in 84 cases on the right and 60 cases on the left. Twenty two donors underwent right nephrectomy due to presence of multiple renal arteries on the left (N=14), proximal bifurcation of left main renal artery (N=3), and young females in reproductive age (N=5). Unexpected abnormalities found with angiogram were seen in 7 cases and they include renal artery stenosis (N=2), renal cysts (N=4) and focal infarction (N=1). In cases of the renal cysts and focal infarction, there were no serious complications related to the abnormalities. It is conclude that intra-arterial digital subtraction angiography is safe and efficient method to image renal anatomy of the potential renal donors

  5. Contrast-enhanced magnetic resonance angiography: evaluation of renal arteries in living renal transplant donors

    International Nuclear Information System (INIS)

    Firat, Ali; Akin, Oguz; Muhtesem Agildere, Ahmet; Aytekin, Cuneyt; Haberal, Mehmet

    2004-01-01

    One of the most important steps before living-donor nephrectomy is assessment of renal vascular anatomy. The number, origins and lengths of the renal arteries and variations of renal veins must be determined in order to identify the kidney that is most suitable for transplantation. Digital subtraction angiography was long considered the standard procedure for this purpose, but this method has been replaced by non-invasive techniques. Contrast-enhanced magnetic resonance angiography is an accurate, safe and reliable method for imaging vasculature. This article reviews the technique and the clinical features of this method in the evaluation of living renal transplant donors

  6. Contrast-enhanced magnetic resonance angiography: evaluation of renal arteries in living renal transplant donors

    Energy Technology Data Exchange (ETDEWEB)

    Firat, Ali; Akin, Oguz; Muhtesem Agildere, Ahmet; Aytekin, Cuneyt; Haberal, Mehmet

    2004-10-01

    One of the most important steps before living-donor nephrectomy is assessment of renal vascular anatomy. The number, origins and lengths of the renal arteries and variations of renal veins must be determined in order to identify the kidney that is most suitable for transplantation. Digital subtraction angiography was long considered the standard procedure for this purpose, but this method has been replaced by non-invasive techniques. Contrast-enhanced magnetic resonance angiography is an accurate, safe and reliable method for imaging vasculature. This article reviews the technique and the clinical features of this method in the evaluation of living renal transplant donors.

  7. Venous digital subtraction angiography for diagnosis of renal artery stenosis in arterial hypertony

    International Nuclear Information System (INIS)

    Schoerner, W.; Kempter, H.; Banzer, D.; Aviles, C.; Weiss, T.; Felix, R.

    1984-01-01

    Venous digital subtraction angiography was performed in 248 patients for the diagnosis of renal arterial stenosis. In 88% of the investigations the stenosis could be found. Comparison of digital angiography and conventional angiography was made for 57 renal arteries (25 investigations). In 52 renal arteries we found the same results with both methods, in 5 renal arteries we found the same results with both methods, in 5 renal arteries the digital angiography showed false positive results. The spatial resolution of digital subtraction angiography is sufficient for the correct diagnosis of significant renal arterial stenosis. With regard to the lower invasion of digital subtraction angiography compared to conventional angiography the first method should be used for clarification of renal arterial hypertension. (orig.)

  8. MR angiography and the preoperative evaluation of renal arteries

    International Nuclear Information System (INIS)

    Nakahara, Kimitoshi; Yokoyama, Hiroshi; Tsuji, Yuji

    2001-01-01

    To determine the accuracy of gadolinium-enhanced, three-dimensional, magnetic resonance angiography (3D-MRA) in the visualization of the arterial anatomy of the kidney, we compared preoperative 3D-MRA results with surgical findings in 37 patients who underwent renal surgery. 3D-MRA findings were confirmed surgically in 30 of these patients (81%). However, 4 of 7 accessory renal arteries were missed by this imaging technique. Furthermore, 3D-MRA failed to visualize renal arteries in all of the three atrophic kidneys. 3D-MRA is a safe and reliable procedure for the preoperative evaluation of renal arteries. However, the depiction of smaller renal arteries, such as accessory and atrophic arteries, is less accurate. (author)

  9. MR angiography and the preoperative evaluation of renal arteries

    Energy Technology Data Exchange (ETDEWEB)

    Nakahara, Kimitoshi; Yokoyama, Hiroshi; Tsuji, Yuji [Fukuoka Univ. (Japan). School of Medicine

    2001-04-01

    To determine the accuracy of gadolinium-enhanced, three-dimensional, magnetic resonance angiography (3D-MRA) in the visualization of the arterial anatomy of the kidney, we compared preoperative 3D-MRA results with surgical findings in 37 patients who underwent renal surgery. 3D-MRA findings were confirmed surgically in 30 of these patients (81%). However, 4 of 7 accessory renal arteries were missed by this imaging technique. Furthermore, 3D-MRA failed to visualize renal arteries in all of the three atrophic kidneys. 3D-MRA is a safe and reliable procedure for the preoperative evaluation of renal arteries. However, the depiction of smaller renal arteries, such as accessory and atrophic arteries, is less accurate. (author)

  10. CT angiography of the renal arteries and veins: normal anatomy and variants.

    Science.gov (United States)

    Hazırolan, Tuncay; Öz, Meryem; Türkbey, Barış; Karaosmanoğlu, Ali Devrim; Oğuz, Berna Sayan; Canyiğit, Murat

    2011-03-01

    Conventional angiography has long been regarded as gold standard imaging modality for evaluation of the renal vasculature. Introduction of multidetector computed tomography (MDCT) angiography had a groundbreaking impact on evaluation of the renal vessels and is gradually replacing conventional angiography as standard imaging. Herein, we review and illustrate the normal and variant anatomy of renal vessels with special emphasis on imaging protocols and reconstruction techniques in MDCT.

  11. Renal artery and parenchymal changes after renal denervation: assessment by magnetic resonance angiography

    Energy Technology Data Exchange (ETDEWEB)

    Sanders, Margreet F.; Vink, Eva E.; Blankestijn, Peter J. [University Medical Center Utrecht, Department of Nephrology and Hypertension, PO Box 85500, Utrecht (Netherlands); Doormaal, Pieter Jan van; Habets, Jesse; Vonken, Evert-Jan; Leiner, Tim [University Medical Center Utrecht, Department of Radiology, Utrecht (Netherlands); Beeftink, Martine M.A.; Verloop, Willemien L.; Voskuil, Michiel [University Medical Center Utrecht, Department of Cardiology, Utrecht (Netherlands); Bots, Michiel L. [University Medical Center Utrecht, Julius Center for Health Sciences and Primary Care, Utrecht (Netherlands); Fadl Elmula, Fadl Elmula M. [Oslo University Hospital, Department of Internal Medicine and Department of Cardiology, Ullevaal, Oslo (Norway); Hammer, Frank [Cliniques Universitaires Saint-Luc, Universite Catholique de Louvain, Department of Radiology, Brussels (Belgium); Hoffmann, Pavel [Oslo University Hospital, Section for Interventional Cardiology, Department of Cardiology, Ullevaal, Oslo (Norway); Jacobs, Lotte; Staessen, Jan A. [University of Leuven, Studies Coordinating Centre, Research Unit Hypertension and Cardiovascular Epidemiology, KU Leuven Department of Cardiovascular Sciences, Leuven (Belgium); Mark, Patrick B.; Taylor, Alison H. [University of Glasgow, Institute of Cardiovascular and Medical Sciences, Glasgow, Scotland (United Kingdom); Persu, Alexandre; Renkin, Jean [Universite Catholique de Louvain, Pole of Cardiovascular Research, Institut de Recherche Experimentale et Clinique, Brussels (Belgium); Cliniques Universitaires Saint-Luc, Universite Catholique de Louvain, Cardiology Department, Brussels (Belgium); Roditi, Giles [Glasgow Royal Infirmary, Department of Radiology, Glasgow (United Kingdom); Spiering, Wilko [University Medical Centre Utrecht, Department of Vascular Medicine, Utrecht (Netherlands); Collaboration: on behalf of the European Network COordinating research on Renal Denervation (ENCOReD) Consortium

    2017-09-15

    Relatively little is known about the incidence of long-term renal damage after renal denervation (RDN), a potential new treatment for hypertension. In this study the incidence of renal artery and parenchymal changes, assessed with contrast-enhanced magnetic resonance angiography (MRA) after RDN, is investigated. This study is an initiative of ENCOReD, a collaboration of hypertension expert centres. Patients in whom an MRA was performed before and after RDN were included. Scans were evaluated by two independent, blinded radiologists. Primary outcome was the change in renal artery morphology and parenchyma. MRAs from 96 patients were analysed. Before RDN, 41 renal anomalies were observed, of which 29 mostly mild renal artery stenoses. After a median time of 366 days post RDN, MRA showed a new stenosis (25-49% lumen reduction) in two patients and progression of pre-existing lumen reduction in a single patient. No other renal changes were observed and renal function remained stable. We observed new or progressed renal artery stenosis in three out of 96 patients, after a median time of 12 months post RDN (3.1%). Procedural angiographies showed that ablations were applied near the observed stenosis in only one of the three patients. (orig.)

  12. The postprocessing techniques in renal artery reconstructions and clinical application with multidetector spiral CT angiography

    International Nuclear Information System (INIS)

    Yu Yuanxin; Liang Changhong; Zhang Zhonglin; Xie Shufei; Liu Yubao; Tang Xiangzhou

    2005-01-01

    Objective: To investigate the value and predominance for imaging postprocessing techniques of renal artery variation and lesions by multidetector spiral CT angiography. Methods: 51 patients with renal artery disease including 12 artery variation, 27 artery stenosis, 3 renal anenrysm, 3 thrombosis of renal artery and 3 dissecting aneurysm of renal artery by SSD, MIP and CPR were enrolled. The effectiveness of these imaging postprocessing methods was compared, 29 of them were confirmed by DSA and 3 by operation, others were checked by MRA and follow up. Results: All abnormalities and diseases were cleariy displayed. The specificity and sensitivity were 100% respectively. In the all imaging postprocessing techniques, MPR can clearly display the calcification of the arteries, stenosis, embolism, aneurysm but do not display the anatomy satisfactorily. MIP can not only clearly display the anatomy but display the different configurations. VR can display the artery figures but can not display the information of lumen of blood vessels. SSD can display the complex vessel anatomy but it was influenced by its threshold selection. CPR can spread and display directly the tortuous renal artery and measure the section area of stenosis. Conclusions: MSCTA is helpful to accurately display the renal artery variation and lesions. Both MIP and VR are the best choice to illustrate the renal artery abnormalities. And MPR and SSD are assistant in the diagnosis of' renal artery lesions. (authors)

  13. The use of Metrizamid in experimental renal angiography

    International Nuclear Information System (INIS)

    Pokorny, L.; Kelemen, J.

    1980-01-01

    A possible application of the non-ionizing contrast material metrizamid (Amipaque Vascularsup(R), Amipaquesup(R)) for renal angiography was experimentally investigated in dogs. 1.5, 3, 10 or 25 ml contrast medium was injected into one kidney. The animals were killed immediately, 3 hours, 24 hours, 7 or 28 days after angiography, and the kidneys were histologically investigated. In several cases the angiograms showed small alterations (transitory vasospasm, inhomogeneous spots on the nephrogram). Histology revealed in the initial period a homogeneous, pinkish, protein-like substance in the Bowman capsule and in the lumen of the tubuli, whereas later infiltrations by round cells and local accumulation of connective tissues were found. (L.E.)

  14. Selective angiography in fifty patients with primary hepatocellular carcinoma

    Energy Technology Data Exchange (ETDEWEB)

    Shou-Zhong, Wang; Xing-Rong, Chen; Gong-Xian, Wang

    1983-06-01

    Selective angiography is of great importance in the diagnosis of primary hepatocellular carcinoma. It offers information on the findings, multicentricity, localisation, extension, and type of growth. This paper discusses angiography from the methodical point of view, the findings to be obtained, the types of hepatocellular carcinoma, and the diagnostic efficiency of selective angiography in the evaluation of this type of tumour.

  15. Digital subtaction angiography (DSA) in renal-related conditions

    International Nuclear Information System (INIS)

    Kim, Dae Ho; Jeong, Seong Wook; Bae, Kwang Soo; Chung, Moo Chan; Kim, Ki Jeong

    1986-01-01

    DSA (Digital Subtraction Angiography) is a valuable diagnostic imaging method in many clinical fields, including renal-related conditions. Sixty four renal DSA examination were performed in 59 patients with renal-related diseases from Jan. 1984 to Dec. 1985. Summary of These were as follows: 1. Intraarterial(IA)-DSA is performed in 6 cases, intravenous(IV)-DSA in 58 cases. In 58 Examinations of IV-DSA, diagnostic image quality is obtained in 51 cases (88%). 2. In investigations of a possible renovascular etiology of hypertension, IV-DSA is a simple, safe, sensitive and accurate method. On screening for evaluation of renovascular hypertension, RSP should be replaced with IV-DSA, because IV-DSA is more sensitive and accurate and can detect not only anatomic change of renal artery but also functional hemodynamic change. 3. IV-DSA is valuable in diseases with morphologic changes of vessels. In characterization of a known renal mass, and evaluation of hematuria, suspected aneurysm and renal trauma, IV-DSA is very useful diagnostic imaging modality. 4. In evaluation of potential renal donors, IV-DSA is an accurate and safe method with 82.4% of accuracy. IV-DSA also is useful in follow-up of allograft recipients. 5. In investigation of diabetic nephropathy, glomerulonephritis, pyelonephritis, IV-DSA is little helpful. 6. The advantages of DSA are well known, particularly post-procedure process using computer program is helpful for obtaining information's of hemodynamic change or time-suquence-curve of density etc. More technical improvement with this modality is required for improvement of the image quality and resolution. And more accumulation of clinical experience is required in order to increase the diagnostic accuracy.

  16. Digital subtaction angiography (DSA) in renal-related conditions

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Dae Ho; Jeong, Seong Wook; Bae, Kwang Soo; Chung, Moo Chan; Kim, Ki Jeong [Soon Chun Hyang University College of Medicine, Asan (Korea, Republic of)

    1986-10-15

    DSA (Digital Subtraction Angiography) is a valuable diagnostic imaging method in many clinical fields, including renal-related conditions. Sixty four renal DSA examination were performed in 59 patients with renal-related diseases from Jan. 1984 to Dec. 1985. Summary of These were as follows: 1. Intraarterial(IA)-DSA is performed in 6 cases, intravenous(IV)-DSA in 58 cases. In 58 Examinations of IV-DSA, diagnostic image quality is obtained in 51 cases (88%). 2. In investigations of a possible renovascular etiology of hypertension, IV-DSA is a simple, safe, sensitive and accurate method. On screening for evaluation of renovascular hypertension, RSP should be replaced with IV-DSA, because IV-DSA is more sensitive and accurate and can detect not only anatomic change of renal artery but also functional hemodynamic change. 3. IV-DSA is valuable in diseases with morphologic changes of vessels. In characterization of a known renal mass, and evaluation of hematuria, suspected aneurysm and renal trauma, IV-DSA is very useful diagnostic imaging modality. 4. In evaluation of potential renal donors, IV-DSA is an accurate and safe method with 82.4% of accuracy. IV-DSA also is useful in follow-up of allograft recipients. 5. In investigation of diabetic nephropathy, glomerulonephritis, pyelonephritis, IV-DSA is little helpful. 6. The advantages of DSA are well known, particularly post-procedure process using computer program is helpful for obtaining information's of hemodynamic change or time-suquence-curve of density etc. More technical improvement with this modality is required for improvement of the image quality and resolution. And more accumulation of clinical experience is required in order to increase the diagnostic accuracy.

  17. Three-dimensional renal CT angiography for guiding segmental renal artery clamping during laparoscopic partial nephrectomy

    International Nuclear Information System (INIS)

    Xu, Yi; Shao, Pengfei; Zhu, Xiaomei; Lv, Qiang; Liu, Wangyan; Xu, Hai; Zhu, Yinsu; Yang, Guangyu; Tang, Lijun; Yin, Changjun

    2013-01-01

    Aim: To evaluate the effectiveness of three-dimensional (3D) renal computed tomography angiography (CTA) in guiding segmental renal artery clamping during laparoscopic partial nephrectomy (LPN). Materials and methods: Forty-three patients with renal tumours undergoing renal CTA before LPN were retrospectively enrolled in this study. 3D arteriogram reconstructed images were created to identify the renal tumour-supplying arteries. The number and location of these targeted vessels were annotated on 3D images preoperatively and compared with the clamped vessels during LPN. The consistency between target vessels annotated at CTA and clamped arteries at LPN was compared both using a patient-based analysis and vessel-based analysis. The χ 2 test was applied to analyse the influence of tumour size, location, and growth pattern on the number of clamped segmental renal branches. Results: On patient-based analysis, the number of targeted vessels was consistent with the clamped vessels during LPN in 33 of 43 patients. On vessel-based analysis, 56 of 65 target vessels annotated at CTA were clamped during LPN. More segmental renal branches (p = 0.04) were clamped in patients with tumours of larger size. Tumour location and growth pattern had no association with the number of clamped segmental branches during LPN. Conclusion: High-quality CTA images and 3D reconstruction images can detect detailed information of tumour-supplying arteries to renal tumours. 3D renal CTA is an effective way to guide segmental renal artery clamping during LPN

  18. Renal contrast-enhanced MR angiography: timing errors and accurate depiction of renal artery origins.

    Science.gov (United States)

    Schmidt, Maria A; Morgan, Robert

    2008-10-01

    To investigate bolus timing artifacts that impair depiction of renal arteries at contrast material-enhanced magnetic resonance (MR) angiography and to determine the effect of contrast agent infusion rates on artifact generation. Renal contrast-enhanced MR angiography was simulated for a variety of infusion schemes, assuming both correct and incorrect timing between data acquisition and contrast agent injection. In addition, the ethics committee approved the retrospective evaluation of clinical breath-hold renal contrast-enhanced MR angiographic studies obtained with automated detection of contrast agent arrival. Twenty-two studies were evaluated for their ability to depict the origin of renal arteries in patent vessels and for any signs of timing errors. Simulations showed that a completely artifactual stenosis or an artifactual overestimation of an existing stenosis at the renal artery origin can be caused by timing errors of the order of 5 seconds in examinations performed with contrast agent infusion rates compatible with or higher than those of hand injections. Lower infusion rates make the studies more likely to accurately depict the origin of the renal arteries. In approximately one-third of all clinical examinations, different contrast agent uptake rates were detected on the left and right sides of the body, and thus allowed us to confirm that it is often impossible to optimize depiction of both renal arteries. In three renal arteries, a signal void was found at the origin in a patent vessel, and delayed contrast agent arrival was confirmed. Computer simulations and clinical examinations showed that timing errors impair the accurate depiction of renal artery origins. (c) RSNA, 2008.

  19. Angiography for renal artery stenosis: no additional impairment of renal function by angioplasty

    Energy Technology Data Exchange (ETDEWEB)

    Lufft, Volkmar; Fels, Lueder M.; Egbeyong-Baiyee, Daniel; Olbricht, Christoph J. [Abteilung Nephrologie, Medizinische Hochschule Hannover (Germany); Hoogestraat-Lufft, Linda; Galanski, Michael [Abteilung Diagnostische Radiologie, Medizinische Hochschule Hannover (Germany)

    2002-04-01

    The aim of this study was to compare renal function between patients with renal angiography and patients with renal angiography and angioplasty (AP) for renal artery stenosis (RAS). Forty-seven patients with suspected RAS were prospectively investigated by digital subtraction angiography (DSA) using non-ionic low osmolar contrast media (CM). In 22 patients RAS was detected and in 16 cases an angioplasty was performed in the same session. The following parameters were determined 1 day prior to and after the DSA, respectively: serum creatinine (S-Crea, {mu}mol/l) and single-shot inulin clearance (In-Cl, ml/min) for the evaluation of renal function; and urine alpha 1-microglobuline (AMG, {mu}g/g Crea) and beta-N-acetyl-glucoseaminidase (beta-NAG, U/g Crea) as markers of tubular toxicity. Serum creatinine was measured additionally 2 days after CM had been injected. In both groups with and without AP 174{+-}65 and 104{+-}56 ml of CM (p<0.0005) were used, respectively. There were no differences with regard to renal function or risk factors for CM nephrotoxicity between both groups. In the group with AP S-Crea and In-Cl (each: mean{+-}SD) did not change significantly (before DSA: 171{+-}158 and 61{+-}24, after DSA: 189{+-}177 and 61{+-}25, respectively), beta-NAG (median) rose from 4 to 14 (p<0.05) and AMG from 8 to 55 (n.s., because of high SD). In the group without AP S-Crea increased from 134{+-}109 to 141{+-}113 (p<0.01), In-Cl dropped from 65{+-}26 to 62{+-}26 (p<0,01), beta NAG (median) rose from 4 to 8 (p=0.01), and AMG from 7 to 10 (n.s.). A rise in baseline S-Crea by more than 25% or 44 {mu}mol/l occurred in 4 and 2 patients in the group with and without AP, respectively. Creatinine increase was reversible in all cases within 7 days. In this study using sensitive methods to detect changes of renal function and tubular toxicity no additional renal function impairment in DSA with angioplasty for RAS compared with DSA alone could be demonstrated. Our data suggest

  20. Angiography for renal artery stenosis: no additional impairment of renal function by angioplasty

    International Nuclear Information System (INIS)

    Lufft, Volkmar; Fels, Lueder M.; Egbeyong-Baiyee, Daniel; Olbricht, Christoph J.; Hoogestraat-Lufft, Linda; Galanski, Michael

    2002-01-01

    The aim of this study was to compare renal function between patients with renal angiography and patients with renal angiography and angioplasty (AP) for renal artery stenosis (RAS). Forty-seven patients with suspected RAS were prospectively investigated by digital subtraction angiography (DSA) using non-ionic low osmolar contrast media (CM). In 22 patients RAS was detected and in 16 cases an angioplasty was performed in the same session. The following parameters were determined 1 day prior to and after the DSA, respectively: serum creatinine (S-Crea, μmol/l) and single-shot inulin clearance (In-Cl, ml/min) for the evaluation of renal function; and urine alpha 1-microglobuline (AMG, μg/g Crea) and beta-N-acetyl-glucoseaminidase (beta-NAG, U/g Crea) as markers of tubular toxicity. Serum creatinine was measured additionally 2 days after CM had been injected. In both groups with and without AP 174±65 and 104±56 ml of CM (p<0.0005) were used, respectively. There were no differences with regard to renal function or risk factors for CM nephrotoxicity between both groups. In the group with AP S-Crea and In-Cl (each: mean±SD) did not change significantly (before DSA: 171±158 and 61±24, after DSA: 189±177 and 61±25, respectively), beta-NAG (median) rose from 4 to 14 (p<0.05) and AMG from 8 to 55 (n.s., because of high SD). In the group without AP S-Crea increased from 134±109 to 141±113 (p<0.01), In-Cl dropped from 65±26 to 62±26 (p<0,01), beta NAG (median) rose from 4 to 8 (p=0.01), and AMG from 7 to 10 (n.s.). A rise in baseline S-Crea by more than 25% or 44 μmol/l occurred in 4 and 2 patients in the group with and without AP, respectively. Creatinine increase was reversible in all cases within 7 days. In this study using sensitive methods to detect changes of renal function and tubular toxicity no additional renal function impairment in DSA with angioplasty for RAS compared with DSA alone could be demonstrated. Our data suggest that AP performed for RAS has

  1. Dependence of renal blood flow on renal artery stenosis measured using CT angiography

    Energy Technology Data Exchange (ETDEWEB)

    Luedemann, Lutz [Charite - Universitaetsmedizin Berlin (Germany). Dept. of Radiotherapy; Nafz, B.; Persson, P. [Charite - Universitaetsmedizin Berlin (Germany). Inst. for Vegetative Physiology; Elsner, F. [Krankenhaus am Urban, Berlin (Germany). Dept. of Anesthesiology; Grosse-Siestrup, C.; Meissler, M. [Charite - Universitaetsmedizin Berlin (Germany). Experimental Animal Unit; Gutberlet, M. [Charite - Universitaetsmedizin Berlin (Germany). Dept. of Diagnostic and Interventional Radiology; Univ. Leipzig/ Leipzig Heart Center (Germany). Dept. of Diagnostic and Interventional Radiology; Lengsfeld, P.; Voth, M. [Bayer-Schering Pharma AG, Berlin (Germany). Global Medical Affairs Diagnostic Imaging

    2011-03-15

    The present study investigates the suitability of computed tomography angiography (CTA) depicting the degree of renal artery stenosis for estimating renal blood flow (RBF) in a kidney. Materials and Methods: We investigated renal artery stenosis assessment by CTA in eight adult female hybrid pigs with an ultrasound probe implanted at the renal vein for RBF measurement. An inflatable metal-free cuff was placed around the renal artery to control the RBF. The RBF was then reduced in four steps. For each reduced RBF value and baseline RBF, CTA with a reconstructed slice thickness of 0.625 mm was performed in the arterial phase following injection of 80 ml of nonionic intravenous contrast medium. The radius of the stenotic and non-stenotic renal artery segment was measured in the reconstructed images. Results: A significant linear correlation (p < 0.0001) was found between the relative apparent stenosis (calculated as the ratio of the radii of the actual stenotic segment and a non-stenotic renal artery segment) and RBF. The linear regression yielded a slope of 0.57 and a y-axis of 24.1 %. A significant linear correlation (p < 0.0001) was also found between the relative true stenosis (the ratio of the radii of the actual stenotic segment and a non-stenotic renal artery segment at baseline) and the RBF. The linear regression yielded a slope of 0.67 and a y-axis of 13.8 %. Conclusion: The results show that the relative stenosis apparent on CTA differs from the true degree of renal artery stenosis. Nevertheless, the degree of renal artery stenosis determined by CTA provides a reliable estimate of the resulting RBF reduction. (orig.)

  2. Dependence of renal blood flow on renal artery stenosis measured using CT angiography

    International Nuclear Information System (INIS)

    Luedemann, Lutz; Nafz, B.; Persson, P.; Elsner, F.; Grosse-Siestrup, C.; Meissler, M.; Gutberlet, M.; Univ. Leipzig/ Leipzig Heart Center; Lengsfeld, P.; Voth, M.

    2011-01-01

    The present study investigates the suitability of computed tomography angiography (CTA) depicting the degree of renal artery stenosis for estimating renal blood flow (RBF) in a kidney. Materials and Methods: We investigated renal artery stenosis assessment by CTA in eight adult female hybrid pigs with an ultrasound probe implanted at the renal vein for RBF measurement. An inflatable metal-free cuff was placed around the renal artery to control the RBF. The RBF was then reduced in four steps. For each reduced RBF value and baseline RBF, CTA with a reconstructed slice thickness of 0.625 mm was performed in the arterial phase following injection of 80 ml of nonionic intravenous contrast medium. The radius of the stenotic and non-stenotic renal artery segment was measured in the reconstructed images. Results: A significant linear correlation (p < 0.0001) was found between the relative apparent stenosis (calculated as the ratio of the radii of the actual stenotic segment and a non-stenotic renal artery segment) and RBF. The linear regression yielded a slope of 0.57 and a y-axis of 24.1 %. A significant linear correlation (p < 0.0001) was also found between the relative true stenosis (the ratio of the radii of the actual stenotic segment and a non-stenotic renal artery segment at baseline) and the RBF. The linear regression yielded a slope of 0.67 and a y-axis of 13.8 %. Conclusion: The results show that the relative stenosis apparent on CTA differs from the true degree of renal artery stenosis. Nevertheless, the degree of renal artery stenosis determined by CTA provides a reliable estimate of the resulting RBF reduction. (orig.)

  3. An experimental study on renal arterial and parenchymal change caused by selective renal infusion of epinephrine

    International Nuclear Information System (INIS)

    Jeon, Seok Chol; Yeon, Kyung Mo; Han, Man Chung

    1981-01-01

    Selective infusion of the epinephrine into the renal artery has been used in the field of the diagnostic and the therapeutic radiology for correct diagnosis and effective treatment, respectively. However, administration of overdose of epinephrine may cause serious complication, renal infarction. The study was undertaken to evaluate the sequential change of renal arterial constrictive effect of selective infusion of epinephrine into renal artery and to determine the critical doses of epinephrine producing irreversible renal infarct. A total of 25 rabbits are used, which are divided into 5 groups. Under the general anesthesia is made the selective infusion of various doses of epinephrine into the right renal artery of the rabbits. At the various time interval during and after the epinephrine infusion, renal angiography was done, and 24 hrs. later, gross and microscopic findings of the kidney were observed. The results are as follows; 1. Vasoconstriction of renal artery occurred within 2 mins. infusion, and maximum effect within 5 mins. 2. It seems that there is correlation between the amount of infused epinephrine and the time taken to recover from constriction of renal artery. 3. When epinephrine is infused into the renal artery in the rate of 1 ug/min., renal infarct is not noticed below the level of 10 mins., but correlation between the amount of infused epinephrine and the frequency of renal infarct occurs above 20 mins. infusion

  4. Multidetector spiral CT renal angiography in the diagnosis of renal artery fibromuscular dysplasia

    International Nuclear Information System (INIS)

    Sabharwal, Rohan; Vladica, Philip; Coleman, Patrick

    2007-01-01

    Objective: The aim of this study was to evaluate the role and detection rate of multidetector spiral CT renal angiography (CTA) as compared with conventional angiography (CA), the commonly accepted gold standard, in the diagnosis of renal artery fibromuscular dysplasia (FMD). In addition, the role of CTA reconstructions (multiplanar reformatted images (MPR), maximum intensity projections (MIP) and shaded-surface display (SSD)) in the detection of FMD was also evaluated. Materials and methods: CTA results were retrospectively reviewed in 21 hypertensive patients with CA-proven FMD. Clinical indications for referral included resistant hypertension (requiring greater than three antihypertensive medications), labile hypertension, hypertension in combination with renal impairment and the presence of abdominal bruits in the context of systemic hypertension. In some cases, these clinical indications were supplemented by positive results in other tests, including plasma renin assay, captopril scintigraphy and/or Doppler ultrasound. The findings of CA in these 21 patients were compared to CTA. Results: Mean patient age was 62.33 + 14.32 years (range 24-85 years). CTA identified all 42 main renal arteries (100%) and all 10 accessory renal arteries (100%) visualized on CA. In the diagnosis of FMD, CTA detected all 40 (100%) lesions detected by CA. No single CTA reconstruction technique was able to detect all lesions noted on corresponding CA, however, upon review of all CTA reconstructions (MPR, MIP and SSD) in each case, every lesion was correctly identified by CTA. Conclusion: Our experience suggests that CTA is a non-invasive, reliable and accurate method for the diagnosis of renal artery fibromuscular dysplasia. Moreover, in our experience CTA has many advantages as a diagnostic screening tool over CA, including accessibility, speed, lower complication profile, versatility and cost-effectiveness. CTA shows great potential as a guiding tool for directing subsequent

  5. Comparison of digital subtraction angiography with gadolinium-enhanced magnetic resonance angiography in the diagnosis of renal artery stenosis

    International Nuclear Information System (INIS)

    Thornton, J.; O'Callaghan, J.; Varghese, J.C.; Lee, M.J.; Walshe, J.; O'Brien, E.

    1999-01-01

    Renal artery stenosis (RAS) is a treatable cause of hypertension and renal failure for which no ideal screening technique is currently available. We evaluated the use of dynamic gadolinium-enhanced magnetic resonance angiography (MRA) for the diagnosis of RAS. Sixty-two patients with secondary hypertension were enrolled in the study. All patients had conventional renal angiography and gadolinium enhanced MRA. The sequence used was a 3D FMP SPGR sequence with the following parameters (TR: 26 ms, TE: 6.9 ms, flip angle 40 , field of view 36 x 36 cm, matrix 246 x 256, 1 excitation). Gadolinium 0.3 mmol/kg was administered and 60 1.5-mm-thick partitions were obtained over a duration of 3.5 min. The MRA images were then compared with conventional digital subtraction angiography (DSA) images. Conventional DSA demonstrated 138 renal arteries, whereas gadolinium-enhanced MRA demonstrated 129 (93 %). Twenty-one renal artery stenoses and four occluded arteries were seen at conventional DSA. Gadolinium-enhanced MRA had a sensitivity of 88 %, specificity of 98 %, accuracy of 96 %, positive predictive value of 92 % and negative predictive value of 97 % when compared with conventional DSA. Gadolinium-enhanced MRA is an accurate technique for identifying patients with RAS. It is less sensitive in picking up accessory renal arteries. (orig.)

  6. Transbrachial artery approach for selective cerebral angiography

    International Nuclear Information System (INIS)

    Touho, Hajime; Karasawa, Jun; Shishido, Hisashi; Morisako, Toshitaka; Numazawa, Shinichi; Yamada, Keisuke; Nagai, Shigeki; Shibamoto, Kenji

    1990-01-01

    Transaxillary or transbrachial approaches to the cerebral vessels have been reported, but selective angiography of all four vessels has not been possible through one route. In this report, a new technique for selective cerebral angiography with transbrachial approach is described. One hundred and twenty three patients with cerebral infarction, vertebrobasilar insufficiency, intracerebral hemorrhage, epilepsy, or cerebral tumor were examined. Those patients consisted of 85 outpatients and 38 inpatients whose age ranged from 15 years old to 82 years old. The patients were examined via the transbrachial approach (97 cases via the right brachial, 29 cases via the left). Materials included a DSA system (Digital Fluorikon 5000, General Electric Co.), a 4 French tight J-curved Simmons 80-cm catheter, a 19-gauge extra-thin-wall Seldinger needle, and a J/Straight floppy 125-cm guide-wire. Generally, the volume of the contrast agent (300 mgI/ml iopamidol) used in the common carotid artery angiogram was 6 ml, while that used in the vertebral artery angiogram was 4 ml. If catheterization of the vertebral artery or right common carotid artery was unsuccessful, about 8 ml of the contrast agent was injected into the subclavian or branchiocephalic artery. Definitive diagnosis and a decision on proper treatment of the patients can be easily obtained, and the results were clinically satisfactory. Moreover, no complications were encountered in this study. This new technique making a transbrachial approach to the cerebral vessels using the DSA system is introduced here. Neurosurgeons can use this technique easily, and they will find that it provides them with all the information they need about the patient. (author)

  7. Comparison of two-dimensional MR angiography and microsphere measurement of renal blood flow for detection of renal artery stenosis

    International Nuclear Information System (INIS)

    Powers, T.A.; Lorenz, C.H.; Shetty, A.N.; Holburn, G.E.; Price, R.R.

    1990-01-01

    This paper compares depiction of the renal arteries by MR angiography to renal blood flow as determined with microspheres in a dog model of renal artery stenosis. A left renal artery stenosis was created by placement of a silk ligature. Nb-95-labeled microspheres were injected into the left ventricle and a reference blood sample was drawn. The dog was imaged in the 1.5-T MR imager with two-dimensional MR angiography sequences. The kidneys were excised, weighted, divided into sections, and counted. Two dogs were studied to date. In dog 1, left renal blood flow (RBF) was 42 mL/min/100 g and right RBF was 337 mL/min/100 g. In dog 2 left RBF was 44 mL/min/100 g and right RBF was 608 mL/min/100 g

  8. Characterization of normal feline renal vascular anatomy with dual-phase CT angiography.

    Science.gov (United States)

    Cáceres, Ana V; Zwingenberger, Allison L; Aronson, Lillian R; Mai, Wilfried

    2008-01-01

    Helical computed tomography angiography was used to evaluate the renal vascular anatomy of potential feline renal donors. One hundred and fourteen computed tomography angiograms were reviewed. The vessels were characterized as single without bifurcation, single with bifurcation, double, or triple. Multiplicity was most commonly seen for the right renal vein (45/114 vs. 3/114 multiple left renal veins, 0/114 multiple right renal arteries, and 8/114 multiple left renal arteries). The right kidney was 13.3 times more likely than the left to have multiple renal veins. Additional vascular variants included double caudal vena cava and an accessory renal artery. For the left kidney, surgery and computed tomography angiography findings were in agreement in 92% of 74 cats. For the right kidney, surgery and computed tomography angiography findings were in agreement in 6/6 cats. Our findings of renal vascular anatomy variations in cats were similar to previous reports in humans. Identifying and recognizing the pattern of distribution of these vessels is important when performing renal transplantation.

  9. Rotational digital subtraction angiography of the renal arteries: technique and evaluation in the study of native and transplant renal arteries.

    Science.gov (United States)

    Seymour, H R; Matson, M B; Belli, A M; Morgan, R; Kyriou, J; Patel, U

    2001-02-01

    Rotational digital subtraction angiography (RDSA) allows multidirectional angiographic acquisitions with a single injection of contrast medium. The role of RDSA was evaluated in 60 patients referred over a 7-month period for diagnostic renal angiography and 12 patients referred for renal transplant studies. All angiograms were assessed for their diagnostic value, the presence of anomalies and the quantity of contrast medium used. The effective dose for native renal RDSA was determined. 41 (68.3%) native renal RDSA images and 8 (66.7%) transplant renal RDSA images were of diagnostic quality. Multiple renal arteries were identified in 9/41 (22%) native renal RDSA diagnostic images. The mean volume of contrast medium in the RDSA runs was 51.2 ml and 50 ml for native and transplant renal studies, respectively. The mean effective dose for 120 degrees native renal RDSA was 2.36 mSv, equivalent to 1 year's mean background radiation. Those RDSA images that were non-diagnostic allowed accurate prediction of the optimal angle for further static angiographic series, which is of great value in transplant renal vessels.

  10. Multislice CT Angiography in Renal Artery Stent Evaluation: Prospective Comparison with Intra-Arterial Digital Subtraction Angiography

    International Nuclear Information System (INIS)

    Raza, Syed A.; Chughtai, Aamer R.; Wahba, Mona; Cowling, Mark G.; Taube, David; Wright, Andrew R.

    2004-01-01

    Purpose: To assess the role of multislice computed tomography angiography (MCTA) in the evaluation of renal artery stents, using intra-arterial digital subtraction angiography (DSA) as the gold standard. Methods: Twenty consecutive patients (15 men, 5 women) with 23 renal artery stents prospectively underwent both MCTA and DSA. Axial images, multiplanar reconstructions and maximum intensity projection images were used for diagnosis. The MCTA and DSA images were each interpreted without reference to the result of the other investigation. Results:The three cases of restenosis on DSA were detected correctly by MCTA; in 19 cases where MCTA showed a fully patent stent, the DSA was also negative. Sensitivity and negative predictive value (NPV) of MCTA were therefore 100%. In four cases, MCTA showed apparently minimal disease which was not shown on DSA. These cases are taken as false positive giving a specificity of 80% and a positive predictive value of 43%. Conclusion: The high sensitivity and NPV suggest MCTA may be useful as a noninvasive screen for renal artery stentrestenosis. MCTA detected mild disease in a few patients which was not confirmed on angiography

  11. Time-resolved MR angiography of the renal artery: morphology and perfusion

    International Nuclear Information System (INIS)

    Krause, U.J.; Pabst, T.; Koestler, H.; Helbig, C.; Kenn, W.; Hahn, D.

    2002-01-01

    Purpose: To prove the hypothesis that renal artery stenosis and changes in renal perfusion can be detected with contrast-enhanced time-resolved MR angiography in a single examination. Material and Methods: In 71 patients, 137 renal arteries and 14 accessory renal arteries were studied. The examinations were performed on a 1.5 T system. A T 1 -weighted gradient echo sequence with a temporal resolution of 7 s was used. Single dose of contrast material (0.1 mmol/kg Gd-DTPA) was injected with a power injector with a flow rate of 2 ml/s. Criterion for the assessment of renal perfusion was the slope ratio of the signal intensity time curve in both kidneys. Results: Forty renal artery stenoses and one occlusion of a renal artery were detected. In 48 kidneys (35%) segmental arteries were evaluated. The accuracy of the slope ratio (limit value 0.75) concerning the detection of unilateral renal artery stenosis was 92.6% (sensitivity 75%, specificity 95.7%). Conclusion: Time-resolved MR angiography can detect changes in renal perfusion in patients with unilateral renal artery stenosis. (orig.) [de

  12. Multidetector CT angiography in living donor renal transplantation: accuracy and discrepancies in right venous anatomy.

    Science.gov (United States)

    Kulkarni, S; Emre, S; Arvelakis, A; Asch, W; Bia, M; Formica, R; Israel, G

    2011-01-01

    Multidetector computed tomography (MDCT) angiography is a reliable technique for assessing pre-operative renal anatomy in living kidney donors. The method has largely evolved into protocols that eliminate dedicated venous phase and instead utilize a combined arterial/venous phase to delineate arterial and venous anatomy simultaneously. Despite adoption of this protocol, there has been no study to assess its accuracy. To assess whether or not MDCT angiography compares favorably to intra-operative findings, 102 donors underwent MDCT angiography without a dedicated venous phase with surgical interpretation of renal anatomy. Anatomical variants included multiple arteries (12%), multiple veins (7%), early arterial bifurcation (13%), late venous confluence (5%), circumaortic renal veins (5%), retroaortic vein (1%), and ureteral duplication (2%). The sensitivity and specificity of multiple arterial anomalies were 100% and 97%, respectively. The sensitivity and specificity of multiple venous anomalies were 92% and 98%, respectively. The most common discrepancy was noted exclusively in the interpretation of right venous anatomy as it pertained to the renal vein/vena cava confluence (3%). MDCT angiography using a combined arterial/venous contrast-enhanced phase provides suitable depiction of renal donor anatomy. Careful consideration should be given when planning a right donor nephrectomy whether the radiographic interpretation is suggestive of a late confluence. © 2010 John Wiley & Sons A/S.

  13. Variations in Branching Pattern of Renal Artery in Kidney Donors Using CT Angiography.

    Science.gov (United States)

    Munnusamy, Kumaresan; Kasirajan, Sankaran Ponnusamy; Gurusamy, Karthikeyan; Raghunath, Gunapriya; Bolshetty, Shilpakala Leshappa; Chakrabarti, Sudakshina; Annadurai, Priyadarshini; Miyajan, Zareena Begum

    2016-03-01

    Each kidney is supplied by a single renal artery originating from abdominal aorta. Since there are lots of renal surgeries happening now-a-days, it becomes mandatory for the surgeons to understand the abnormality and variations in the renal vasculature. To study the variations in the branching pattern of renal artery for the presence of early division and accessory renal artery in Indian kidney donors using CT angiography. The CT angiogram images of 100 normal individuals willing for kidney donation were analysed for early divisions and occurrence of accessory renal artery. A 51% of kidney donors showed variation in the renal artery. Out of 51% variations 38 individuals had accessory renal artery and 13 individuals had early division of renal artery. The distribution of accessory renal artery was equal on both sides (13% on right and left) and 12% of individuals had accessory renal artery on both sides. Out of 13% earlier divisions, 5% was on right side, 7% was on left side and 1% was on both sides. This study concludes that 51% of kidney donors had renal artery variations. Hence, awareness of variations by evaluating the donors is a must before renal transplantation, urological procedures and angiographic interventions.

  14. The Utility of 64 Channel Multidetector CT Angiography for Evaluating the Renal Vascular Anatomy and Possible Variations: a Pictorial Essay

    International Nuclear Information System (INIS)

    Kumar, Sheo; Neyaz, Zafar; Gupta, Archna

    2010-01-01

    The increased use of laparoscopic nephrectomy and nephron-sparing surgery has prompted the need for a more detailed radiological evaluation of the renal vascular anatomy. Multidetector CT angiography is a fast and accurate modality for assessing the precise anatomy of the renal vessels. In this pictorial review, we present the multidetector CT angiography appearances of the normal renal vascular anatomy and a spectrum of various anomalies that require accurate vascular depiction before undergoing surgical treatment

  15. The Utility of 64 Channel Multidetector CT Angiography for Evaluating the Renal Vascular Anatomy and Possible Variations: a Pictorial Essay

    Energy Technology Data Exchange (ETDEWEB)

    Kumar, Sheo; Neyaz, Zafar; Gupta, Archna [Sanjay Gandhi Post Graduate Institute of Medical Sciences, Lucknow (India)

    2010-06-15

    The increased use of laparoscopic nephrectomy and nephron-sparing surgery has prompted the need for a more detailed radiological evaluation of the renal vascular anatomy. Multidetector CT angiography is a fast and accurate modality for assessing the precise anatomy of the renal vessels. In this pictorial review, we present the multidetector CT angiography appearances of the normal renal vascular anatomy and a spectrum of various anomalies that require accurate vascular depiction before undergoing surgical treatment.

  16. The utility of 64 channel multidetector CT angiography for evaluating the renal vascular anatomy and possible variations: a pictorial essay.

    Science.gov (United States)

    Kumar, Sheo; Neyaz, Zafar; Gupta, Archna

    2010-01-01

    The increased use of laparoscopic nephrectomy and nephron-sparing surgery has prompted the need for a more detailed radiological evaluation of the renal vascular anatomy. Multidetector CT angiography is a fast and accurate modality for assessing the precise anatomy of the renal vessels. In this pictorial review, we present the multidetector CT angiography appearances of the normal renal vascular anatomy and a spectrum of various anomalies that require accurate vascular depiction before undergoing surgical treatment.

  17. Visualization of the renal venous system by renal arteriography with digital subtraction angiography

    International Nuclear Information System (INIS)

    Nagai, Jun

    1989-01-01

    The purpose of this study was to obtain vivid and precise images of intrarenal venous branching using DSA for renal arteriography. The type of system used was an ADAC DPS-4100C with 70-80 kVp, and 320 mA, 25-50 msec at 6 frames/sec. The duration was 10 sec and the matrix size was 512x512. In order to retain clear subtracted images of intrarenal venous branching with minimal noise the three frames were selected on the time-density curve of DSA: (Fig.3). 1) a frame on which renal arteries disappear (frame X), 2) the frame with highest renal venous density value as (frame Y), 3) the difference of the nephrogram density between X and Y frames in which only the density of the nephrogram decreases (frame Z). The mask image is the image subtracted by the equation of the weighted averaging method on X and Z frame and is subtracted from the image of Y frame in the final step. By this method, 40 kidneys in 36 patients were studied, and the intrarenal venous branches up to the interlobar vein was clearly demonstrated in 28 of these cases (70%). This method is useful to estimate the extent of intrarenal lesions and detect abnormal renal blood flow compared with conventional temporal subtraction method. (author)

  18. Investigation of renovascular hypertension with 99mTC-DTPA dynamic renal scanning and digital subtraction angiography

    International Nuclear Information System (INIS)

    Stavraka-Kakavakis, A.; Vlontjou, E.; Apostolopoulos, D.; Mourikis, D.; Venetsanakis, N.; Lazarou, S.; Vlahos, L.

    1989-01-01

    Sixty-four selected hypertensive patients, aged 17-45 years, were evaluated for renovascular hypertension. They were studied with 99m TC-DTPA dynamic renal scanning (DRS) and intravenous digital subtraction angiography (IV-DSA). Intra-arterial DSA was further performed to demonstrate renal vascular anatomy in all disputable cases. Agreement of diagnosis occurred in 58 patients (32 with renal artery stenosis). There was one false positive with DRS and one false positive with IV-DSA. In another four patients with proven renovascular disease, IV-DSA was positive while DRS negative, but in two of them the stenotic lesion was considered insignificant, as they failed to respond to percutaneous transluminal dilatation (PTA). In contrast, nearly all patients whose hypertension improved after PTA or surgery had positive DRS and greater than 40% reduction of relative function of the affected kidney. IV-DSA yielded better results than DRS in the detection of renal arterial stenosis (especially whenever bilateral stenosis or rich collateral circulation was present), but DRS showed better correlation with the functional significance of a certain vascular abnormality. Thus the combination of the two methods seems to be a reasonable diagnostic approach to hypertensive patients with the aim of selecting those with curable hypertension due to renal vascular disease. (orig.)

  19. Multiple detector-row CT angiography of the renal and mesenteric vessels

    Energy Technology Data Exchange (ETDEWEB)

    Fleischmann, Dominik. E-mail: dominik.fleischmann@univie.ac.at

    2003-03-01

    Computed tomography angiography (CTA) of the abdomen with multiple detector-row computed tomography (MD-CT) is an effective technique for minimally invasive imaging of the renal arteries and the visceral vasculature. This article reviews the clinical and technical aspects of MD-CT angiography in terms of image acquisition and reconstruction parameters, contrast medium application, and three-dimensional visualization with special attention to renal and mesenteric vascular imaging. Because of its high sensitivity to detect renal artery stenosis on the one hand, and because a normal renal CTA virtually excludes the presence of a significant renal artery stenosis on the other hand, renal CTA plays a useful role in the management of patients with suspected renovascular hypertension. Mesenteric CTA is a useful tool for visualizing normal vascular anatomy and its variants--particularly in the setting of organ transplantation. Vascular pathology, e.g. atherosclerotic disease (abdominal angina), or aneurysms of the visceral arteries are reliably assessed with CTA. Mesenteric CTA is an invaluable adjunct to abdominal CT in the setting of abdominal emergencies, because of its ability to detect the causes of acute intestinal ischemia (superior mesenteric artery embolism or thrombosis, superior mesenteric vein thrombosis). Accurate timing of the CTA acquisition and the subsequent parenchymal phase acquisition relative to the contrast medium transit time is critical to obtain excellent image quality in double-pass abdominal CT acquisitions.

  20. Clinical role of non-contrast magnetic resonance angiography for evaluation of renal artery stenosis

    International Nuclear Information System (INIS)

    Utsunomiya, Daisuke; Nomitsu, Yohei; Komeda, Yosuke; Okigawa, Takashi; Urata, Joji; Miyazaki, Mitsue; Yamashita, Yasuyuki

    2008-01-01

    The association between a gadolinium-based contrast material and nephrogenic systemic fibrosis has been discussed. The purpose of our study was to evaluate whether non-contrast enhanced magnetic resonance angiography (MRA) might provide sufficient information of renal artery stenosis. The non-contrast MRA of 26 patients with hypertension was retrospectively reviewed in the present study. The significant renal artery stenosis was visually evaluated by comparing non-contrast MRA with computed tomography or conventional angiographic finding. Difference of the intensities between the proximal and distal aorta was quantitatively evaluated. The sensitivity, specificity, positive predictive value and negative predictive value of non-contrast MRA in the evaluation of the renal artery stenosis was 78%, 91%, 64% and 96%, respectively. The distal abdominal aorta showed less signal intensity than the proximal aorta by 16.9±12.2%. Non-contrast MRA is a non-invasive and effective method that allows evaluation of the renal artery stenosis. (author)

  1. Helical CT angiography of renal arteries: two-years of experience

    International Nuclear Information System (INIS)

    Beregi, J.P.; Louvegny, S.; Ceugnart, L.; Willoteaux, S.; Elkohen, M.; Desmoucelle, F.; Deklunder, G.; Wattinne, L.

    1997-01-01

    To evaluate the role of helical CT angiography (CTA) in the detection of renal artery stenosis in hypertensive patients. We studied 300 hypertensive patients (50 prospectively and 250 consecutively) with CTA and arteriography (n = 118). Helical acquisition (collimation 3 mm; pitch = 1, 20 seconds acquisition time) was performed 20-45 seconds after contrast injection (300 mgl/ml; 120 ml, 4 ml/sec. Transverse axial views and 3D reconstructions were analysed (360 deg interpolation algorithm, 1 mm overlapped). In the prospective series, CTA sensibility was 100 % for main renal artery stenoses and specificity was 98.2 %; however 7/32 renal accessory arteries were not visualized. In the 300 patients studies, seventy-four stenoses were detected. There were 5 false-positive and 5 false-negative studies. Secondary hypertension was detected in 26 % of patients (including 14 cases of adrenal hyperplasia). CTA is a promising technique for the detection of renal artery stenosis in hypertensive patients. (authors)

  2. Value of contrast-enhanced 3D MR angiography of the renal arteries

    International Nuclear Information System (INIS)

    Hany, T.F.; Pfammatter, T.; Schmidt, M.; Leung, D.A.; Debatin, J.F.

    1997-01-01

    Purpose: To determine the value of gadolinium-enhanced, three-dimensional breath-hold Magnetic Resonance Angiography (MRA) in the assessment of the aorta and renal arteries in comparison to conventional arteriography (CA). Patients and methods: 49 patients were evaluated with both CA and 3D MRA. 0.3 mmol/kg BW gadolinium-DTPA was administered intravenously in a bolus, using an automated injector. A test bolus method was used for timing of the bolus and beginning of the data acquisition. The intraaterial CA was used as the gold standard. Results: MRA-based assessment of renal artery stenosis was identical with CA in 31 of 45 stenoses (68.8%). Senstivity and specificity for assessment of renal arterial disease by MRA were 84% and 96%; for clinically relevant lesions they amounted to 90% and 98%. Conclusion: The presented contrast-enhanced 3D MRA technique allows for the reliable assessment of renal arterial morphology and pathology. (orig.) [de

  3. Bilateral renal cell carcinoma in a horseshoe kidney: preoperative assessment with MRI and digital subtraction angiography

    International Nuclear Information System (INIS)

    Schubert, R.A.; Soeldner, J.; Kaiser, W.A.; Steiner, T.; Schubert, J.

    1998-01-01

    Renal cell carcinoma in a horseshoe kidney is an unusual entity. To our knowledge, only 123 cases have been published to date. We report the first bilateral case of two clear-cell carcinomas in an asymmetrically fused kidney. Optimum preservation of renal function after radical tumor removal requires accurate preoperative imaging. Since the vascular supply in fusion anomalies is extremely variable, angiography is mandatory. Magnetic resonance imaging was most suitable to predict the tumor extent and localization, because it simultaneously gave the most comprehensive anatomical overview of the malformation. (orig.)

  4. Angiography

    International Nuclear Information System (INIS)

    Grinnell, V.S.; Mehringer, C.M.; Hieshima, G.B.

    1987-01-01

    The history of angiography is short, with its centennial approaching. A very brief review of milestones begins with the discovery of x-rays in 1895. Only a few months later contrast agents too toxic for human use were being injected into cadavers, severed limbs, and animals. The next major developments came in the late 1970s when percutaneous translumbar aortography and cerebral angiography were described. Contrast agents were now less toxic, and clinically useful angiography was a reality. In 1953 a technique for percutaneous vascular catheterization which formed the basis of many catheterization techniques to follow was described. In the 1970s the development of less invasive diagnostic methods such as computed tomography and diagnostic ultrasound decreased the indications for angiography, but newer interventional techniques such as embolization therapy and angioplasty have taken up the slack. Angiography remains the most important way to demonstrate vascular diseases graphically. Specific techniques such as angioplasty and digital subtraction angiography will be dealt with in other chapters. The authors hope to provide an overview of major areas of angiographic utilization. The basic techniques of arterial puncture and catheterization have been well described elsewhere

  5. Normal renal arterial anatomy assessed by multidetector CT angiography: are there differences between men and women?

    Science.gov (United States)

    Turba, Ulku Cenk; Uflacker, Renan; Bozlar, Ugur; Hagspiel, Klaus D

    2009-03-01

    The purpose of this study was to determine renal arterial anatomy and gender differences in adults without renovascular disease using multidetector computed tomography angiography (MDCTA). MDCTA datasets of 399 patients were retrospectively reviewed. Measurements of the aortorenal diameters, the angulation of the renal ostia and pedicles as well as the distance between the origins of the renal arteries were measured. Differences in measurements between genders were tested for statistical significance using analysis of variance (ANOVA) and Pearson's Chi-Square tests. A total of 798 renal arteries were available for analysis in 207 female (mean age = 52.91 years) and 192 male patients (mean age = 53.04 years). Female patients were found to have smaller aortae (at the level of the right renal ostium) and bilateral renal arteries than males (mean aortic diameter M/F = 18.33/15.89 mm, mean right renal artery ostial diameter M/F = 5.06/4.59 mm, mean left ostial renal diameter M/F = 5.14/4.66 mm) (p renal ostia level in relation to the vertebrae and the majority of renal arteries originated at the L1 and L2 levels. The longitudinal distance between right and left renal artery ostia ranged from 0 to 32 mm (mean = 4,6 mm, median = 5mm). The mean anteroposterior orientation of the right renal ostia was M/F = 29.45 degrees/28.20 degrees , and M/F = -7.96 degrees/-11.14 degrees for left renal artery ostia. The mean anteroposterior orientation of the right renal pedicle was M/F = 41.37 degrees/44.34 degrees and M/F = 42.31 degrees/43.95 degrees for the left pedicle. There are some differences in normal renal arterial anatomy between genders. Normal renal arterial information is useful not only for planning and performing of endovascular and laparoscopic urologic procedures, but also for medical device development. Copyright 2009 Wiley-Liss, Inc.

  6. Evaluation of renal vascular in living donors before transplantation using dynamic contrast enhanced MR angiography

    International Nuclear Information System (INIS)

    Wang Hong; Mu Xuetao; Zhong Xin; Dong Yuru; Dong Yue; Ma Yi; Wu Chunnan

    2010-01-01

    Objective: To explore whether dynamic contrast-enhanced MRA (DCE MRA) can provide an effective assessment of renal vascular in living donors before transplantation. Methods: Thirty five healthy living renal donor candidates were scanned on MR system before transplantation. After injection of Gd-DTPA 1 ml in vein, a test-bolus scan was used to get the time delay of Gd-DTPA reaching renal artery. Then, a 3D T 1 -weighted fast low-angle shot sequence (3D FLASH) was performed in the coronal plane. The 3D FLASH scan would repeat four times with an inter-phase of 10 seconds. Thus, the imaging of the renal arterial, venous and collecting systems were got. Two radiologists observed renal arteries and veins on original imaging and MIP reconstmcted imaging. The quality of MR angiography was evaluated on a five- point scale and the vascular anatomy or variations of the arterial and venous systems were recorded, using intraoperative findings as a standard of reference. Results: The quality for all MRA was good or very good for the most of living renal donors. Among 70 renals, several variations of vascular were found, including 5 left accessory artery, 9 right accessory artery, 3 left proximal arterial branch and 6 right proximal arterial branch. Among 70 renal veins, 1 right accessory veins and 2 left varicocele were observed. One small accessory artery of right kidney was missed with DCE MRA, but identified by operation. Conclusion: DCE MRA was noninvasive tool for evaluation of the renal vasculature and variations with high accuracy. It would be a good modality in preoperative evaluation of living renal donors. (authors)

  7. Magnetic resonance angiography in renal grafts. Comparison with color Doppler echography

    International Nuclear Information System (INIS)

    Yanagisawa, Takayoshi; Otsubo, Osamu; Nozaki, Harushige

    1995-01-01

    We studied relationship between magnetic resonance angiography (MRA) of renal graft and renal graft function in 14 renal transplantations (10 from living donors, 4 from cadaveric donors). MRA was performed on 0.3-T permanent magnet system (MRP 7000, HITACHI, JAPAN) using 2 dimensional time of flight technique (FOV: 350 mm 2 , RT: 60 msec, ET: 10 msec, FA: 90deg, Slice: volumes 60, thickness 4 mm, overlap 1 mm). As for parameters of renal graft function, we evaluated color doppler echography (CD) of transplanted renal artery, renal blood flow (RBF), velocity of interlobar artery (ILA) and serum creatinine level (S-Cr). CD, RBF and velocity of ILA were visualized and measured by duplex color doppler echosystem (EUB-565A, HITACHI, JAPAN). Depending on visualization of transplanted renal artery, MRA was graded into 3 groups (MA Grade 3: visualization of ILA, MA Grade 2: visualization of segmental artery and the first branch but no visualization of ILA, MA Grade 1: visualization of main renal artery only). Likewise, visualization of CD was graded into 3 groups (CD Grade 3: good visualization of arcuate artery (AA) and ILA, CD Grade 2: poor visualization of AA but good visualization of ILA, CD Grade 1: poor visualization of ILA). The MRA grading had a very significant correlation (r=0.79, p<0.001) with the CD grading. As for RBF and velocity of ILA, the RBF of MA Grade 3 group (n=8) was significantly (p<0.05) higher than the MA Grade 2 group (n=4) and the MA Grade 1 group (n=2), and the velocity of ILA of MA Grade 3 group was also higher than the above groups but not significantly. Furthermore, the S-Cr of MA Grade 3 was significantly (p<0.05) lower than the others. These results showed that MRA of renal graft had a qualitative index of renal graft function. (author)

  8. Value of downstream circulation in renal artery stenosis with arterial hypertension: comparison between color Doppler flow and digital renal angiography in 123 patients

    International Nuclear Information System (INIS)

    Grataloup, C.; Challande, P.; Plainfosse, M.C.; Girerd, X.; Belattar, K.; Plouin, P.F.

    1996-01-01

    Digital renal angiography and color Doppler flow were compared for diagnosis of renal artery stenosis in 123 hypertensive patients with a prevalence of renal artery stenosis ≥75% of 21 %. Only color Doppler flow signs found downstream from the stenosis could be quantified. A rising time (RT) >0.07 s was the best marker for renal artery stenosis ≥ 75 % according to a receiver operating characteristic curve with a specificity of 97 %, a sensitivity of 88 %, a positive predictive value of 86 %, a negative predictive value of 98 % and an accuracy of 96 %. Digital renal angiography and color Doppler flow findings for renal artery lesions were classified into 4 degrees with agreement for 86 % of the kidneys. (authors). 13 refs., 5 figs., 8 tabs

  9. Spectrum of results of arterial digital subtraction angiography in patients after renal transplantation

    International Nuclear Information System (INIS)

    Gruetzner, G.; Bach, D.; Fluer, P.; Kniemeyer, H.W.; Moedder, U.

    1994-01-01

    Digital subtraction angiography (DSA) was performed in 53 of 417 patients with renal transplants. The incidence of clinical apparent vascular complications was 9.1% of all patients with renal transplants (38/417). The most frequent vascular disorders were formed by arterial stenoses at 5.0% of the cases followed by arterial obstructions in 1.7% of the patients. Rare vascular complications were arteriovenous fistulas (0.7%), aneurysms (0.5%) and venous thrombose (0.2%). Because of the high diagnostic value of intraarterial DSA, all patients with renal transplants with a complicated postoperative course should be eligible for angiographic control. In case of a suspected vascular disorder intraarterial DSA should be performed at an early stage. (orig.)

  10. The transradial approach for selective carotid and vertebral angiography

    Energy Technology Data Exchange (ETDEWEB)

    Iwasaki, S.; Ueda, K.; Sueyosi, S.; Nagasawa, M.; Ude, K. [Higashiosaka City General Hospital, Osaka (Japan). Dept. of Radiology; Yokoyama, K. [Higashiosaka City General Hospital, Osaka (Japan). Dept. of Neurosurgery; Takayama, K.; Nakagawa, H.; Kichikawa, K. [Nara Medical Univ., Osaka (Japan). Dept. of Radiology

    2002-11-01

    Purpose: The transradial approach is not so popular in cerebral angiography. The purpose of this study was therefore to present our experience of success rate and safety of this method. Material and Methods: From December 1998 to June 2001, 526 carotid and vertebral angiographies with DSA were performed via the radial artery. A 1.4-mm catheter was used through a 1.4-mm introducer sheath. We evaluated the procedure as successful if sufficient images for diagnosis were obtained of the bilateral carotid arteries and unilateral vertebral artery. Each patient was reassessed for any complications, occurring until the next morning. The length of time needed for an examination was measured in the last 10 cases. Results: In all but 5 cases, the procedures were evaluated as successful (99.0%). Unsuccessful cases manifested severe pain at the radial puncture, angiospasm at the radial artery, loop formation at the radial artery, occlusion at the subclavian artery, and an aberrant right subclavian artery. No severe complications including neurological ones were encountered. Minor complications were noted in 17 cases (3.2%): 4 cases of thrombus at the ulnar artery, 1 angiospasm at the radial artery, and 12 cases of small hematoma at the puncture site. The radial approach took 14 min less in the common carotid study and 3 min 30 s less in the internal carotid study than by the femoral approach. Conclusion: The transradial approach enabled selective studies for carotid and vertebral angiography with a high success rate and safety with few complications.

  11. The transradial approach for selective carotid and vertebral angiography

    International Nuclear Information System (INIS)

    Iwasaki, S.; Ueda, K.; Sueyosi, S.; Nagasawa, M.; Ude, K.; Yokoyama, K.; Takayama, K.; Nakagawa, H.; Kichikawa, K.

    2002-01-01

    Purpose: The transradial approach is not so popular in cerebral angiography. The purpose of this study was therefore to present our experience of success rate and safety of this method. Material and Methods: From December 1998 to June 2001, 526 carotid and vertebral angiographies with DSA were performed via the radial artery. A 1.4-mm catheter was used through a 1.4-mm introducer sheath. We evaluated the procedure as successful if sufficient images for diagnosis were obtained of the bilateral carotid arteries and unilateral vertebral artery. Each patient was reassessed for any complications, occurring until the next morning. The length of time needed for an examination was measured in the last 10 cases. Results: In all but 5 cases, the procedures were evaluated as successful (99.0%). Unsuccessful cases manifested severe pain at the radial puncture, angiospasm at the radial artery, loop formation at the radial artery, occlusion at the subclavian artery, and an aberrant right subclavian artery. No severe complications including neurological ones were encountered. Minor complications were noted in 17 cases (3.2%): 4 cases of thrombus at the ulnar artery, 1 angiospasm at the radial artery, and 12 cases of small hematoma at the puncture site. The radial approach took 14 min less in the common carotid study and 3 min 30 s less in the internal carotid study than by the femoral approach. Conclusion: The transradial approach enabled selective studies for carotid and vertebral angiography with a high success rate and safety with few complications

  12. Renal MR angiography and perfusion in the pig using hyperpolarized water.

    Science.gov (United States)

    Wigh Lipsø, Kasper; Hansen, Esben Søvsø Szocska; Tougaard, Rasmus Stilling; Laustsen, Christoffer; Ardenkjaer-Larsen, Jan Henrik

    2017-09-01

    To study hyperpolarized water as an angiography and perfusion tracer in a large animal model. Protons dissolved in deuterium oxide (D 2 O) were hyperpolarized in a SPINlab dissolution dynamic nuclear polarization (dDNP) polarizer and subsequently investigated in vivo in a pig model at 3 Tesla (T). Approximately 15 mL of hyperpolarized water was injected in the renal artery by hand over 4-5 s. A liquid state polarization of 5.3 ± 0.9% of 3.8 M protons in 15 mL of deuterium oxide was achieved with a T 1 of 24 ± 1 s. This allowed injection through an arterial catheter into the renal artery and subsequently high-contrast imaging of the entire kidney parenchyma over several seconds. The dynamic images allow quantification of tissue perfusion, with a mean cortical perfusion of 504 ± 123 mL/100 mL/min. Hyperpolarized water MR imaging was successfully demonstrated as a renal angiography and perfusion method. Quantitative perfusion maps of the kidney were obtained in agreement with literature and control experiments with gadolinium contrast. Magn Reson Med 78:1131-1135, 2017. © 2016 International Society for Magnetic Resonance in Medicine. © 2016 International Society for Magnetic Resonance in Medicine.

  13. Intravenous digital subtraction angiography and helical computed tomography in evaluation of living renal donors

    International Nuclear Information System (INIS)

    Watarai, Yoshihiko; Usuki, Tomoaki; Takeuchi, Ichiro; Nonomura, Katsuya; Koyanagi, Tomohiko; Kubo, Kozo; Hirano, Tetsuo; Togashi, Masaki; Ohashi, Nobuo

    2001-01-01

    The present study was carried out to evaluate the accuracy of helical computed tomography (CT) and intravenous digital subtraction angiography (IV-DSA) on anatomical assessment of renal vasculature for living renal donors. Forty-two healthy potential renal donors were prospectively evaluated and 35 subsequently underwent donor nephrectomy after helical CT and IV-DSA evaluation. The vascular and non-vascular findings were compared between the findings on helical CT, IV-DSA and surgery. Ten prehilar branches and five accessory renal arteries were found at nephrectomy. Overall, operative findings agreed with the findings by IV-DSA in 89% and by helical CT in 83%. In delineating accessory arteries, IV-DSA had a sensitivity of 60% and specificity of 97%, whereas helical CT had a sensitivity of 40% and specificity of 100%. In delineating prehilar branches, IV-DSA had a sensitivity of 90% and specificity of 100%, whereas helical CT had a sensitivity of 70% and specificity of 100%. Accessory arteries and prehilar branches that were not detected by helical CT or IV-DSA, were less than 2 mm in diameter and did not require vascular reconstruction. Renal veins were delineated in 63% by IV-DSA, whereas they were clearly imaged by helical CT in all cases, including a case with a circumaortic renal vein. Non-vascular findings were obtained in 64% by helical CT, including two renal tumors. None of these findings were obtained by IV-DSA. Helical CT and IV-DSA provide comparably sufficient information on renal artery vasculature. However, helical CT provides significantly more information on venous and non-vascular findings as a single-imaging modality. (author)

  14. Contrast enhanced renal MR angiography at 7 Tesla: How much gadolinium do we need?

    Energy Technology Data Exchange (ETDEWEB)

    Beiderwellen, Karsten, E-mail: karsten.beiderwellen@uni-due.de [Department of Diagnostic and Interventional Radiology and Neuroradiology, University Hospital Essen, Essen (Germany); Erwin L. Hahn Institute for Magnetic Resonance Imaging, University Duisburg-Essen, Essen (Germany); Kraff, Oliver, E-mail: Oliver.kraff@uni-due.de [Erwin L. Hahn Institute for Magnetic Resonance Imaging, University Duisburg-Essen, Essen (Germany); Laader, Anja, E-mail: anja.laader@uk-essen.de [Department of Diagnostic and Interventional Radiology and Neuroradiology, University Hospital Essen, Essen (Germany); Erwin L. Hahn Institute for Magnetic Resonance Imaging, University Duisburg-Essen, Essen (Germany); Maderwald, Stefan, E-mail: Stefan.maderwald@uni-due.de [Erwin L. Hahn Institute for Magnetic Resonance Imaging, University Duisburg-Essen, Essen (Germany); Orzada, Stephan, E-mail: Stephan.orzada@uni-due.de [Erwin L. Hahn Institute for Magnetic Resonance Imaging, University Duisburg-Essen, Essen (Germany); Ladd, Mark E., E-mail: mark.ladd@dkfz-heidelberg.de [Medical Physics in Radiology, German Cancer Research Center (DKFZ), Heidelberg (Germany); Forsting, Michael, E-mail: Michael.forsting@uk-essen.de [Department of Diagnostic and Interventional Radiology and Neuroradiology, University Hospital Essen, Essen (Germany); Erwin L. Hahn Institute for Magnetic Resonance Imaging, University Duisburg-Essen, Essen (Germany); Lauenstein, Thomas C., E-mail: Thomas.Lauenstein@uni-due.de [Department of Diagnostic and Interventional Radiology and Neuroradiology, University Hospital Essen, Essen (Germany); Umutlu, Lale, E-mail: Lale.umutlu@uk-essen.de [Department of Diagnostic and Interventional Radiology and Neuroradiology, University Hospital Essen, Essen (Germany); Erwin L. Hahn Institute for Magnetic Resonance Imaging, University Duisburg-Essen, Essen (Germany)

    2017-01-15

    Objectives: To investigate whether a dose reduction of Gadobutrol for renal magnetic resonance angiography (MRA) at 7 Tesla (T) is feasible while preserving diagnostic image quality. Methods: Ten healthy volunteers were enrolled for a renal MRA on a 7 T scanner. Fast low angle shot (FLASH) MRA data sets were obtained utilizing three different doses of Gadobutrol (0.1, 0.05 and 0.025 mmol/kg body weight [BW]). Contrast ratios (CR) were measured in the aorta as well as in the intra- and extraparenchymal arteries compared to the psoas muscle. Qualitative analysis regarding the delineation of vessel structures was performed using a four-point-scale. Results: All doses of Gadobutrol allowed for a good delineation of the aorta and renal arteries. For the extra- and intraparenchymal segmental arteries higher values were observed for full and half dose in comparison to quarter dose. No significant difference was observed for full and half dose. A lower CR was observed for quarter compared to half dose (p < 0.05) for the renal arteries. Conclusions: While best results were observed for half and full dose, a dose reduction to 0.025 mmol/kg BW is justifiable, maintaining a diagnostic image quality. This may be of high interest considering patients with renal impairment.

  15. Selective angiography of the avascular necrosis of the femoral head

    Energy Technology Data Exchange (ETDEWEB)

    Choi, Joong Chan; Park, Cheong Hee; Rho, Tae Jin; Yune, Seung Ho; Rhee, Byung Chull [Chung Nam National University College of Medicine, Deajeon (Korea, Republic of)

    1988-10-15

    The diagnosis of the avascular of the femoral head (AVN) has advanced. RI scan, intraosseous pressure monitoring, intramedullary venography, CT, MRI, and selective femoral angiography are used in diagnosis. Among these methods, selective or superselective angiography is necessary to study the change of the vessels of the hip, because the vascular insufficiency could be a major etiology of AVN. Selective femoral angiography was performed for 23 hips of 22 patients who were suspected as AVN by simple rediographs and RI scans in order to estimate the change of vascularity of the femoral head. The results were as follow. 1. The alteration of vasculature appeared in 21 cases among all 23 cases (91%), which included 100% in the traumatic group (4/4 cases) and 90% in nontraumatic group (17/19 cases). 2. The affected vessles in nontraumatic group were the proximal portion of the posterior branch of the medical circumflex artery in 2 cases, the modportion of posterior branch in 2 cases, the distal portion of the posterior branch in 11 cases, and superior capsular branch in 2 cases. 3. The affected vessels in traumatic group were proximal portion in 1 cases, midportion in 1 case, and superior capsular artrey in 2 cases. 4. The obstruction of inferior casular artery was noted in 6 cases of nontraumatic group. 5. The retrograde filling of the posterior branch of medial circumflex artery were noted in 1 case from superior gluteal artery, in 1 case from inferior gluteal artery, in 1 case form superior and inferior gluteal artery and retrograde filling of inferior gluteal artery from medial circumflex artery was in 6 cases.

  16. Selective angiography of the avascular necrosis of the femoral head

    International Nuclear Information System (INIS)

    Choi, Joong Chan; Park, Cheong Hee; Rho, Tae Jin; Yune, Seung Ho; Rhee, Byung Chull

    1988-01-01

    The diagnosis of the avascular of the femoral head (AVN) has advanced. RI scan, intraosseous pressure monitoring, intramedullary venography, CT, MRI, and selective femoral angiography are used in diagnosis. Among these methods, selective or superselective angiography is necessary to study the change of the vessels of the hip, because the vascular insufficiency could be a major etiology of AVN. Selective femoral angiography was performed for 23 hips of 22 patients who were suspected as AVN by simple rediographs and RI scans in order to estimate the change of vascularity of the femoral head. The results were as follow. 1. The alteration of vasculature appeared in 21 cases among all 23 cases (91%), which included 100% in the traumatic group (4/4 cases) and 90% in nontraumatic group (17/19 cases). 2. The affected vessles in nontraumatic group were the proximal portion of the posterior branch of the medical circumflex artery in 2 cases, the modportion of posterior branch in 2 cases, the distal portion of the posterior branch in 11 cases, and superior capsular branch in 2 cases. 3. The affected vessels in traumatic group were proximal portion in 1 cases, midportion in 1 case, and superior capsular artrey in 2 cases. 4. The obstruction of inferior casular artery was noted in 6 cases of nontraumatic group. 5. The retrograde filling of the posterior branch of medial circumflex artery were noted in 1 case from superior gluteal artery, in 1 case from inferior gluteal artery, in 1 case form superior and inferior gluteal artery and retrograde filling of inferior gluteal artery from medial circumflex artery was in 6 cases.

  17. Diagnosis of ischemic vertebral collapse using selective spinal angiography

    International Nuclear Information System (INIS)

    Stojanovic, J.; Kovac, V.

    1981-01-01

    During the year of 1980 we observed 3 patients with a vertebral collapse of indistinct origin. As there was no recent trauma in the past history, selective spinal angiography (SSA) was used to clarify the diagnosis. In each of the three cases we found evident rarefaction, in some places even an occlusion of the arteries of the adjacent affected vertebra. On the bases of this finding we concluded that this might be an ischemic vertebral collapse, an entity which had been under discussion long ago but not exactly confirmed so far. (orig.) [de

  18. Optimized contrast volume for dynamic CT angiography in renal transplant patients using a multiphase CT protocol

    International Nuclear Information System (INIS)

    Helck, A.; Bamberg, F.; Sommer, W.H.; Wessely, M.; Becker, C.; Clevert, D.A.; Notohamiprodjo, M.; Reiser, M.; Nikolaou, K.

    2011-01-01

    Objectives: To study the feasibility of an optimized multiphase renal-CT-angiography (MP-CTA) protocol in patients with history of renal transplantation compared with Doppler-ultrasound (DUS). Methods: 36 Patients underwent both DUS and time-resolved, MP-CTA (12 phases), with a mean contrast-volume of 34.4 ± 5.1 ml. Quality of MP-CTA was assessed quantitatively (vascular attenuation) and qualitatively (grades 1–4, 1 = best). For the assessment of clinical value of MP-CTA, cases were grouped into normal, macrovascular (arterial/venous) and microvascular complications (parenchymal perfusion defect). DUS served as the standard of reference. Results: Using the best of 12 phases in each patient, optimal attenuation was 353 ± 111 HU, 337 ± 98 HU and 164 ± 51 HU in the iliac arteries, renal arteries, and renal veins, respectively. Mean image quality was 1.1 ± 0.3 (n = 36) and 2.1 ± 0.6 (n = 30) for the transplant renal arteries and veins, respectively. Six renal veins were non-diagnostic in MP-CTA. In 36 patients, MP-CTA showed 13 vascular complications and 10 parenchymal perfusion defects. DUS was not assessable in eight patients. Overall, MP-CTA showed 15 cases with pathology (42%) not identifiable with DUS. The mean effective radiation dose of the MP-CTA protocol was 13.5 ± 5.2 mSv. Conclusion: MP-CTA can be sufficiently performed with reduced contrast volume at reasonable radiation dose in renal transplant patients, providing substantially higher diagnostic yield than DUS.

  19. Multidetector computed tomography angiography of the renal arteries: normal anatomy and its variations

    Directory of Open Access Journals (Sweden)

    Carlos Fernando de Mello Júnior

    2016-06-01

    Full Text Available Abstract Conventional angiography is still considered the gold standard for the study of the anatomy and of vascular diseases of the abdomen. However, the advent of multidetector computed tomography and techniques of digital image reconstruction has provided an alternative means of performing angiography, without the risks inherent to invasive angiographic examinations. Therefore, within the field of radiology, there is an ever-increasing demand for deeper knowledge of the anatomy of the regional vasculature and its variations. Variations in the renal vascular system are relatively prevalent in the venous and arterial vessels. For various conditions in which surgical planning is crucial to the success of the procedure, knowledge of this topic is important. The aim of this study was to familiarize the general radiologist with variations in the renal vascular system. To that end, we prepared a pictorial essay comprising multidetector computed tomography images obtained in a series of cases. We show patterns representative of the most common anatomical variations in the arterial blood supply to the kidneys, calling attention to the nomenclature, as well as to the clinical and surgical implications of such variations.

  20. Multidetector computed tomography angiography of the renal arteries: normal anatomy and its variations

    Energy Technology Data Exchange (ETDEWEB)

    Mello Junior, Carlos Fernando de; Araujo Neto, Severino Aires; Carvalho Junior, Arlindo Monteiro de; Negromonte, Gustavo Ramalho Pessoa; Oliveira, Carollyne Dantas de [Universidade Federal da Paraiba (UFPB), Joao Pessoa, PB (Brazil); Reboucas, Rafael Batista, E-mail: severinoaires@hotmail.com [Faculdade de Ciencias Medicas da Paraiba, Joao Pessoa, PB (Brazil)

    2016-05-15

    Conventional angiography is still considered the gold standard for the study of the anatomy and of vascular diseases of the abdomen. However, the advent of multidetector computed tomography and techniques of digital image reconstruction has provided an alternative means of performing angiography, without the risks inherent to invasive angiographic examinations. Therefore, within the field of radiology, there is an ever-increasing demand for deeper knowledge of the anatomy of the regional vasculature and its variations. Variations in the renal vascular system are relatively prevalent in the venous and arterial vessels. For various conditions in which surgical planning is crucial to the success of the procedure, knowledge of this topic is important. The aim of this study was to familiarize the general radiologist with variations in the renal vascular system. To that end, we prepared a pictorial essay comprising multidetector computed tomography images obtained in a series of cases. We show patterns representative of the most common anatomical variations in the arterial blood supply to the kidneys, calling attention to the nomenclature, as well as to the clinical and surgical implications of such variations. (author)

  1. Multidetector computed tomography angiography of the renal arteries: normal anatomy and its variations

    International Nuclear Information System (INIS)

    Mello Junior, Carlos Fernando de; Araujo Neto, Severino Aires; Carvalho Junior, Arlindo Monteiro de; Negromonte, Gustavo Ramalho Pessoa; Oliveira, Carollyne Dantas de; Reboucas, Rafael Batista

    2016-01-01

    Conventional angiography is still considered the gold standard for the study of the anatomy and of vascular diseases of the abdomen. However, the advent of multidetector computed tomography and techniques of digital image reconstruction has provided an alternative means of performing angiography, without the risks inherent to invasive angiographic examinations. Therefore, within the field of radiology, there is an ever-increasing demand for deeper knowledge of the anatomy of the regional vasculature and its variations. Variations in the renal vascular system are relatively prevalent in the venous and arterial vessels. For various conditions in which surgical planning is crucial to the success of the procedure, knowledge of this topic is important. The aim of this study was to familiarize the general radiologist with variations in the renal vascular system. To that end, we prepared a pictorial essay comprising multidetector computed tomography images obtained in a series of cases. We show patterns representative of the most common anatomical variations in the arterial blood supply to the kidneys, calling attention to the nomenclature, as well as to the clinical and surgical implications of such variations. (author)

  2. Non-contrast magnetic resonance angiography in renal transplantation and renal donation

    DEFF Research Database (Denmark)

    Blankholm, Anne Dorte

    2015-01-01

    for this purpose, including US, CTA and CEMRA. CTA is based on x-ray technology, and the applied iodine-based contrast agent can cause nephropathy and, in rare cases, severe allergic reactions. Allergic reactions to Gd used in CEMRA are extremely rare. Thus, CEMRA was often used for preoperative examination before...... renal transplantation. In 2006, it was realised that the Gd used in CEMRA could cause NSF, which prompted the Danish National Board of Health to produce guidelines for the use of contrast agents in patients with severe renal disease. This thesis discusses different preoperative imaging methods without...... contrast agents before kidney transplantation and kidney donation. Study I is a review of NCMRA techniques and clinical applications. In study II, we searched for an NCMRA method with consistently good image quality for the examination of the pelvic vessels in patients with severe renal disease. Five...

  3. Noncontrast-enhanced magnetic resonance renal angiography using a repetitive artery and venous labelling technique at 3 T: comparison with contrast-enhanced magnetic resonance angiography in subjects with normal renal function

    Energy Technology Data Exchange (ETDEWEB)

    Park, Sung Yoon [Sungkyunkwan University School of Medicine, Department of Radiology and Center for Imaging Science, Samsung Medical Center, Seoul (Korea, Republic of); Severance Hospital, Yonsei University College of Medicine, Department of Radiology and Research Institute of Radiological Science, Seoul (Korea, Republic of); Kim, Chan Kyo; Park, Byung Kwan [Sungkyunkwan University School of Medicine, Department of Radiology and Center for Imaging Science, Samsung Medical Center, Seoul (Korea, Republic of); Kim, EunJu [Philips Healthcare Korea, Seoul (Korea, Republic of)

    2014-09-13

    To investigate the feasibility of noncontrast-enhanced MR angiography (NC-MRA) using the repetitive artery and venous labelling (RAVEL) technique to evaluate renal arteries compared to contrast-enhanced MR angiography (CE-MRA). Twenty-five subjects with normal renal function underwent NC-MRA using a RAVEL technique and CE-MRA at 3 T. Two independent readers analysed the MRA images. Image quality, number of renal arteries, presence or absence of an early branching vessel, and diameter of the main renal arteries were evaluated. The overall image quality of NC-MRA was fair or greater in 88 % of right and 92 % of left renal arteries, while it was 96 % in both sides with CE-MRA. On NC-MRA, the number of renal arteries in all subjects was perfectly predicted by both readers. Sensitivity and specificity for predicting early branching vessels were 82 % and 100 % for reader 1 and 82 % and 95 % for reader 2. Inter-modality agreement for comparing the diameters of main renal arteries was good or excellent at all segments for both readers. Inter-reader agreement was moderate or good at all segments except at the right distal segment on NC-MRA. NC-MRA with the RAVEL technique at 3 T may have comparable diagnostic feasibility for evaluating renal arteries compared to CE-MRA. (orig.)

  4. The pattern of renal vessels in live related potential donors pool. A multislice computed tomography angiography review

    International Nuclear Information System (INIS)

    Mishra, A.; Ehtuish, Ehtuish F.

    2006-01-01

    To assess the renal vessel anatomy, compare the findings with the perioperative findings, to determine the sensitivity of multislice computed tomography (CT) angiography in the work-up of live potential donors and to discuss and compare the results of the present study with the reported results using single slice CT, magnetic resonance (MRI) and conventional angiography (CA).Retrospective analysis of the angiographic data of 118 of prospective live related kidney donors was carried out from October 2004 to August 2005 at the National Organ Transplant Centre, Tripoli Central Hospital, Libya. All donors underwent renal angiography on multislice (16-slice) CT scan using 80 cc intravenous contrast with 1.25 mm slice thickness followed by maximum intensity projection (MIP) and volume rendering techniques (VRT) post-processing algorithms. The number of vessels, vessel bifurcation, vessel morphology and venous anatomy were analyzed and the findings were compared with the surgical findings. Multislice spiral CT angiography (MSCTA) showed clear delineation of the main renal arteries in all donors with detailed vessel morphology. The study revealed 100% sensitivity in detection of accessory renal vessels, with an overall incidence of 26.7%, which is the most common distribution in the parahilar region. The present study showed 100% sensitivity in the visualization and detection of main and accessory renal vessels. These results were comparable with conventional angiography which has so far been considered as the gold standard and were found superior in specificity and accuracy to the use of single slice CT (SSCT) and MR in the angiographic work-up of live renal donors. Due to improved detection of accessory vessels less than 2 mm in diameter, a higher incidence of aberrant vessels was seen on the right side as has been suggested so far. (author)

  5. Fibromuscular dysplasia in living renal donors: Still a challenge to computed tomographic angiography

    International Nuclear Information System (INIS)

    Blondin, D.; Lanzman, R.; Schellhammer, F.; Oels, M.; Grotemeyer, D.; Baldus, S.E.; Rump, L.C.; Sandmann, W.; Voiculescu, A.

    2010-01-01

    Background: Computed tomographic angiography has become the standard evaluating method of potential living renal donors in most centers. Although incidence of fibromuscular dysplasia is low (3.5-6%), this pathology may be relevant for success of renal transplantation. The incidence of FMD in our population of LRD and reliability of CTA for detecting vascular pathology were the aims of this study. Materials and methods: 101 living renal donors, examined between 7/2004 and 9/2008 by CTA, were included in a retrospective evaluation. The examinations were carried out using a 64 Multi-detector CT (Siemens Medical Solutions, Erlangen). The presence or absence of the characteristic signs of fibromuscular dysplasia, as 'string-of-beads' appearance, focal stenosis or aneurysms, were assessed and graded from mild (=1) to severe (=3). Furthermore, vascular anatomy and arterial stenosis were investigated in this study. Retrospective analysis of CTA and ultrasound were compared with operative and histological reports. Results: Four cases of fibromuscular dysplasia (incidence 3.9%) in 101 renal donors were diagnosed by transplanting surgeons and histopathology, respectively. Three cases could be detected by CTA. In one donor even retrospective analysis of CTA was negative. Ten accessory arteries, 14 venous anomalies and 12 renal arteries stenosis due to atherosclerosis were diagnosed by CTA and could be confirmed by the operative report. Conclusion: CTA is sufficient for detection of hemodynamic relevant stenosis and vascular anatomy. Only one patient with a mild form of FMD was under estimated. Therefore, if the CTA shows slightest irregularities which are not typical for atherosclerotic lesions, further diagnostic work up by DSA might still be necessary.

  6. Fibromuscular dysplasia in living renal donors: Still a challenge to computed tomographic angiography

    Energy Technology Data Exchange (ETDEWEB)

    Blondin, D., E-mail: blondin@med.uni-duesseldorf.d [Institute of Radiology, University Hospital Duesseldorf, Moorenstr. 5, D-40225 Duesseldorf (Germany); Lanzman, R.; Schellhammer, F. [Institute of Radiology, University Hospital Duesseldorf, Moorenstr. 5, D-40225 Duesseldorf (Germany); Oels, M. [Department of Nephrology (Germany); Grotemeyer, D. [Department of Vascular Surgery and Renal Transplantation (Germany); Baldus, S.E. [Institute of Pathology (Germany); Rump, L.C. [Department of Nephrology (Germany); Sandmann, W. [Department of Vascular Surgery and Renal Transplantation (Germany); Voiculescu, A. [Department of Nephrology (Germany)

    2010-07-15

    Background: Computed tomographic angiography has become the standard evaluating method of potential living renal donors in most centers. Although incidence of fibromuscular dysplasia is low (3.5-6%), this pathology may be relevant for success of renal transplantation. The incidence of FMD in our population of LRD and reliability of CTA for detecting vascular pathology were the aims of this study. Materials and methods: 101 living renal donors, examined between 7/2004 and 9/2008 by CTA, were included in a retrospective evaluation. The examinations were carried out using a 64 Multi-detector CT (Siemens Medical Solutions, Erlangen). The presence or absence of the characteristic signs of fibromuscular dysplasia, as 'string-of-beads' appearance, focal stenosis or aneurysms, were assessed and graded from mild (=1) to severe (=3). Furthermore, vascular anatomy and arterial stenosis were investigated in this study. Retrospective analysis of CTA and ultrasound were compared with operative and histological reports. Results: Four cases of fibromuscular dysplasia (incidence 3.9%) in 101 renal donors were diagnosed by transplanting surgeons and histopathology, respectively. Three cases could be detected by CTA. In one donor even retrospective analysis of CTA was negative. Ten accessory arteries, 14 venous anomalies and 12 renal arteries stenosis due to atherosclerosis were diagnosed by CTA and could be confirmed by the operative report. Conclusion: CTA is sufficient for detection of hemodynamic relevant stenosis and vascular anatomy. Only one patient with a mild form of FMD was under estimated. Therefore, if the CTA shows slightest irregularities which are not typical for atherosclerotic lesions, further diagnostic work up by DSA might still be necessary.

  7. Ultrafast contrast-enhanced 3D MR angiography of the aorta and renal arteries in apnoea

    International Nuclear Information System (INIS)

    Hany, T.F.; Pfammatter, T.; Schmidt, M.; Leung, D.A.; Debatin, J.F.

    1997-01-01

    Purpose: To determine the value of ultrafast, gadolinium-enhanced, three-dimensional breathhold magnetic resonance angiography (MRA) in the assessment of the aorta and renal arteries in comparison to conventional arteriography (CA). Patients and methods: 49 patients (31 m, 18 f) were evaluated with both CA and 3D MRA. The 3D MRA data set consisted of 44 continuous sections, acquired in apnoea (23-28 s) using the following parameters: T R /T E 3.9/1.5 ms, flip angle 40 , 3/4 k-space acquisition. 0.3 mmol/kg BW gadolinium-DTPA were administered intravenously in a bolus, using an automated injector. A test bolus method was used for timing of the bolus and beginning of the data acquisition. Intraarterial CA was used as the gold standard in 47 patients; in two patients the intraoperative findings were employed as the standard of reference. CA and MRA were interpreted separately by two different radiologists, who were blinded to the results of the other examine. Results: All 11 accessory renal arteries were visualised on MRA. MRA-based assessment of renal artery stenosis was identical with CA in 31 of 41 (75%) stenoses. Sensitivity and specificity values for assessment of renal arterial disease were 84,4% and 96,1%, for haemodynamically significant lesions they amounted to 90% and 98,9%, respectively. Conclusion: The presented ultrafast contrast-enhanced 3D MRA technique allows for the reliable assessment of aortic and renal arterial morphology and pathology. (orig.) [de

  8. Anatomical variations of hepatic arterial system, coeliac trunk and renal arteries: an analysis with multidetector CT angiography.

    Science.gov (United States)

    Ugurel, M S; Battal, B; Bozlar, U; Nural, M S; Tasar, M; Ors, F; Saglam, M; Karademir, I

    2010-08-01

    The purpose of our investigation was to determine the anatomical variations in the coeliac trunk-hepatic arterial system and the renal arteries in patients who underwent multidetector CT (MDCT) angiography of the abdominal aorta for various reasons. A total of 100 patients were analysed retrospectively. The coeliac trunk, hepatic arterial system and renal arteries were analysed individually and anatomical variations were recorded. Statistical analysis of the relationship between hepatocoeliac variations and renal artery variations was performed using a chi(2) test. There was a coeliac trunk trifurcation in 89% and bifurcation in 8% of the cases. Coeliac trunk was absent in 1%, a hepatosplenomesenteric trunk was seen in 1% and a splenomesenteric trunk was present in 1%. Hepatic artery variation was present in 48% of patients. Coeliac trunk and/or hepatic arterial variation was present in 23 (39.7%) of the 58 patients with normal renal arteries, and in 27 (64.3%) of the 42 patients with accessory renal arteries. There was a statistically significant correlation between renal artery variations and coeliac trunk-hepatic arterial system variations (p = 0.015). MDCT angiography permits a correct and detailed evaluation of hepatic and renal vascular anatomy. The prevalence of variations in the coeliac trunk and/or hepatic arteries is increased in people with accessory renal arteries. For that reason, when undertaking angiographic examinations directed towards any single organ, the possibility of variations in the vascular structure of other organs should be kept in mind.

  9. Noncontrast-enhanced magnetic resonance renal angiography using a repetitive artery and venous labelling technique at 3 T: comparison with contrast-enhanced magnetic resonance angiography in subjects with normal renal function.

    Science.gov (United States)

    Park, Sung Yoon; Kim, Chan Kyo; Kim, EunJu; Park, Byung Kwan

    2015-02-01

    To investigate the feasibility of noncontrast-enhanced MR angiography (NC-MRA) using the repetitive artery and venous labelling (RAVEL) technique to evaluate renal arteries compared to contrast-enhanced MR angiography (CE-MRA). Twenty-five subjects with normal renal function underwent NC-MRA using a RAVEL technique and CE-MRA at 3 T. Two independent readers analysed the MRA images. Image quality, number of renal arteries, presence or absence of an early branching vessel, and diameter of the main renal arteries were evaluated. The overall image quality of NC-MRA was fair or greater in 88% of right and 92% of left renal arteries, while it was 96% in both sides with CE-MRA. On NC-MRA, the number of renal arteries in all subjects was perfectly predicted by both readers. Sensitivity and specificity for predicting early branching vessels were 82% and 100% for reader 1 and 82% and 95% for reader 2. Inter-modality agreement for comparing the diameters of main renal arteries was good or excellent at all segments for both readers. Inter-reader agreement was moderate or good at all segments except at the right distal segment on NC-MRA. NC-MRA with the RAVEL technique at 3 T may have comparable diagnostic feasibility for evaluating renal arteries compared to CE-MRA. • Accurate pre-treatment evaluation of renal artery anatomy helps clinical decision-making. • NC-MRA using RAVEL offers acceptable imaging quality for renal artery evaluation. • The 3 T RAVEL technique provides excellent diagnostic performance for renal artery evaluation. • The 3 T RAVEL technique may be an alternative to contrast-enhanced MRA.

  10. Anatomical variants of celiac trunk, hepatic and renal arteries in a population of developing country using multidetector computed tomography angiography

    International Nuclear Information System (INIS)

    Arifuzzaman, M.; Naqvi, S.S.N.; Rasool, M.; Hussain, M.

    2017-01-01

    Background: Multidetector Computed Tomography (MDCT)s has become a major part in evaluation of hepatic and renal tumours. With improvements in MDCT, CT angiography has also improved and normal anatomy and its variants in patients undergoing operative or interventional procedures can be effectively studied. The purpose of this study was to evaluate the frequency of anatomical variation of celiac trunk, hepatic and renal arterial systems in patients undergoing multidetector CT (MDCT) angiography of the abdominal aorta. Methods: A descriptive, retrospective cross-sectional study was carried out on CT angiographies performed during the months of October till December 2015. Hepatic and renal arteries and celiac trunk were studied and normal and anatomical variations were noted. All patients with abnormalities affecting the vessels or a history of any vascular abnormality were excluded from the study. Results: Out of total 110 patients, 69.1% had normal and 30.9% had variant hepatic artery with Michel Type IV being the most common variant whereas 88.2% had normal celiac trunk and 8.2% had gastrosplenic trunk variant. Variation in renal arterial system was observed in 15.5% of the patients with two renal arteries on right and two on left being the most common type. Multiple variants were identified in 11.8% of the patients. Conclusion: The type and knowledge of anatomy is of prime importance for an optimum preoperative planning in surgical or radiological procedure. MDCT allows minimally invasive assessment of arterial anatomy with high quality 3D reconstruction images. (author)

  11. Juxtarenal Aortic Pseudoaneurysm – Right Renal Vein Fistula with Circumaortic Renal Collar-Delayed Manifestation of a Gunshot Injury – an Uncommon Entity Diagnosed with CT Angiography

    International Nuclear Information System (INIS)

    Garg, Lalit; Jain, Neeraj; Agrawal, Sachin; Chauhan, Udit; Goel, Vandana; Puri, Sunil Kumar

    2016-01-01

    Delayed presentation of post-traumatic aortic pseudoaneurysm and its fistulous communication with the right renal vein is a very rare entity. Most of the cases described in literature are due to abdominal aortic aneurysm (AAA) rupture into the left renal vein. To the best of our knowledge, communication with the right renal vein has not been described in published literature. Our patient also had a circumaortic renal collar, which is a rare renal vein anomaly. Aortic pseudoaneurysm, its fistulous communication with the right renal vein and circumaortic renal collar in a single patient is of extremely rare occurrence. A 29-year-old male presented to the cardiology department with complaints of breathlessness, abdominal pain and hematuria for the last 6 months. On clinical examination there was evidence of audible bruit over the abdomen. He had a past history of a gunshot injury around two years back. CT angiography revealed a large partially calcified pseudoaneurysm arising from the right lateral wall of the abdominal aorta with the neck of the pseudoaneurysm at juxtarenal location with a fistula between the anterior wall of the pseudoaneurysm and the posterior wall of the right renal vein. There was an associated incidental finding of circumaortic left renal vein with gross aneurysmal dilatation of both pre- and retro-aortic part of the renal vein. Delayed presentation of aortic pseudoaneurysm with its fistulous communication with the right renal vein is a rare entity. CT angiography is a non-invasive modality for diagnosis of the exact site of communication, length of aneurysm, proximal and distal extent of the affected segment and its relationship with surrounding structures

  12. Intravenous digital subtraction angiography for the evaluation of renal artery blood flow following the removal of a neuroblastoma

    International Nuclear Information System (INIS)

    Yamagiwa, Iwao; Obata, Kazuya; Saito, Hiroyuki; Washio, Masahiko

    1994-01-01

    There have been several reports of acute renal failure following the resection of an abdominal neuroblastoma combined with ipsilateral nephrectomy as well as the atrophy or disappearance of an unresected kidney after tumor resection. Spasms or thrombosis of the renal artery during tumor excision are considered to be the major cause. Since 1989, intravenous digital subtraction angiography (IVDSA) has been used to evaluate the renal artery blood flow immediately following surgery in seven patients with abdominal neuroblastomas. IVDSA was performed using a central venous catheter inserted prior to surgery. In all seven patients, IVDSA provided clear images for the evaluation of renal artery blood flow. In one of the two patients whose kidneys briefly became cyanosed during tumor excision, IVDSA demonstrated an occlusion of the renal artery and prompt measures could be taken to reestablish the blood flow. No complications of IVDSA occurred in any of the seven patients. IVDSA using a central venous catheter was thus considered to be useful for evaluating the renal artery blood flow in patients with a suspected renal artery blood flow disturbance without any risk of complications, and this modality obviated the need for intraarterial angiography. (author)

  13. Contrast-enhanced three-dimensional fast-spoiled gradient magnetic resonance angiography of the renal arteries for potential living renal transplant donors: a comparative study with digital subtraction angiography

    International Nuclear Information System (INIS)

    Al-Saeed, O.; Sheikh, M.; Al-Khawari, H.; Ismail, M.; Al-Moosawi, M.

    2005-01-01

    Preoperative assessment of the arterial anatomy of prospective renal donors is essential. Various non-invasive techniques are used for such evaluation. We conducted this study using contrast-enhanced 3-D fast-spoiled gradient (CE 3-D FSPGR) magnetic resonance angiography (MRA) on a 1.0 Tesla magnet, for preoperative definition of the renal arteries. Forty-five preoperative living renal donors underwent CE 3-D FSPGR MRA of the renal vessels and the results were compared with conventional digital subtraction angiography (DSA). The renal vascular anatomy, both normal and with variations, was satisfactorily defined in all 45 cases with CE 3-D FSPGR MRA. Fifteen cases showed an accessory or aberrant arterial supply. A small aneurysm was shown in one case. All cases compared well with conventional DSA. Our study revealed that CE 3-D FSPGR MRA on a lower field strength magnet is accurate in defining the renal vascular anatomy and its variations. Copyright (2005) Blackwell Science Pty Ltd

  14. Preoperative evaluation of renal anatomy and renal masses with helical CT, 3D-CT and 3D-CT angiography.

    Science.gov (United States)

    Toprak, Uğur; Erdoğan, Aysun; Gülbay, Mutlu; Karademir, Mehmet Alp; Paşaoğlu, Eşref; Akar, Okkeş Emrah

    2005-03-01

    The aim of this prospective study was to determine the efficacy of three-dimensional computed tomography (3D-CT) and three-dimensional computed tomographic angiography (3D-CTA) that were reconstructed by using the axial images of the multiphasic helical CT in the preoperative evaluation of renal masses and demonstration of renal anatomy. Twenty patients that were suspected of having renal masses upon initial physical examination and ultrasonographic evaluation were examined through multiphasic helical CT. Two authors executed CT evaluations. Axial images were first examined and then used to reconstruct 3D-CT and 3D- CTA images. Number, location and size of the renal masses and other findings were noted. Renal vascularization and relationships of the renal masses with the neighboring renal structures were further investigated with 3D-CT and 3D-CTA images. Out of 20 patients, 13 had histopathologically proven renal cell carcinoma. The diagnoses of the remaining seven patients were xanthogranulomatous pyelonephritis, abscess, simple cyst, infected cyst, angiomyolipoma, oncocytoma and arteriovenous fistula. In the renal cell carcinoma group, 3 patients had stage I, 7 patients had stage II, and 3 patients had stage III disease. Sizes of renal cell carcinoma masses were between 23 mm to 60 mm (mean, 36 mm). Vascular invasion was shown in 2 renal cell carcinoma patients. Collecting system invasion was identified in 11 of 13 renal cell patients. These radiologic findings were confirmed with surgical specimens. Three-dimensional CT and 3D-CTA are non-invasive, effective imaging techniques for the preoperative evaluation of renal masses.

  15. Extended Renal Outcomes with Use of Iodixanol versus Iohexol after Coronary Angiography

    Directory of Open Access Journals (Sweden)

    Horng-Ruey Chua

    2014-01-01

    Full Text Available The impact of isoosmolar versus low-osmolar contrast media (CM administration on contrast-induced acute kidney injury (CI-AKI and extended renal dysfunction (ERD is unclear. We retrospectively examined incidences of CI-AKI and ERD in patients who received iodixanol (isoosmolar versus iohexol (low-osmolar during angiography for cardiac indications. Of 713 patients, 560 (cohort A, 190 (cohort B, and 172 (cohort C had serum creatinine monitored at 3 days, 30 days, and 6 months after angiography, respectively. 18% of cohort A developed CI-AKI, which was more common with iodixanol than iohexol (22% versus 13%, P=0.006. However, patients given iodixanol were older with lower baseline estimated glomerular filtration rates (eGFR. On multivariate analysis, independent associations with higher CI-AKI risk include age >65 years, female gender, cardiac failure, ST-elevation myocardial infarction, intra-aortic balloon pump, and critical illness, but not CM type, higher CM load, or eGFR<45 mL/min/1.73 m2. 32% of cohort B and 34% of cohort C had ERD at 30 days and 6 months, while 44% and 41% of subcohorts had ERD at 90 days and 1 year, respectively. CI-AKI, but not CM type, was associated with medium- and longer-term ERD, with 3-fold higher risk. Advanced age, emergent cardiac conditions, and critical illness are stronger predictors of CI-AKI, compared with CM-related factors. CI-AKI predicts longer-term ERD.

  16. Early evaluation of coronary artery bypass grafts: CT or selective angiography

    International Nuclear Information System (INIS)

    Wilson, P.C.; Gutierrez, O.; Moss, A.

    1984-01-01

    A prospective study was performed in 27 patients to compare the value of computed tomography and selective angiography in assessing coronary artery graft patency in the early post-operative period. The sensitivity of CT to graft patency was 85% with no falsely patent determinations. Dynamic CT was not found useful in predicting graft stenosis. There were no complications associated with CT studies, and two related to selective angiography. It is concluded that CT is the procedure of choice for graft evaluation in the early post-operative period; but that angiography is mandatory for the assessment of late symptom recurrence. A review is made of the results described in previous series. (orig.)

  17. Selective spinal angiography and embolization of tumours of the vertebral column

    International Nuclear Information System (INIS)

    Stoeter, P.; Voigt, K.

    1980-01-01

    This paper discusses the technique, the diagnostic and therapeutic value, and the limitations of spinal angiography and embolization in tumours of the vertebral column. Three demonstrative selected cases, in which arterial embolization was performed without subsequent surgery, are discussed. (Auth.)

  18. Assessment of myocardial collateral circulation by intracoronary injection of radioactive microspheres and selective coronary angiography

    International Nuclear Information System (INIS)

    Uhde, W.

    1986-01-01

    In 46 patients selective coronary angiography was performed followed by selective coronary perfusion scintigraphy and a comparative assessment was made of the contralateral coronary collateral circulation. Intracoronary injection of radioactively marked imcrospheres resulted in the detection of microcirculatory processes and made it possible to evaluate the relative efficiency of coronary collaterals. This in turn meant a low-risk supplement and extension of the findings of coronary angiography. This holds particularly true for the area of the left ventricular myocardium. (author)

  19. Assessment of physician and patient (child and adult) equivalent doses during renal angiography by Monte Carlo method

    International Nuclear Information System (INIS)

    Karimian, A.; Nikparvar, B.; Jabbari, I.

    2014-01-01

    Renal angiography is one of the medical imaging methods in which patient and physician receive high equivalent doses due to long duration of fluoroscopy. In this research, equivalent doses of some radiosensitive tissues of patient (adult and child) and physician during renal angiography have been calculated by using adult and child Oak Ridge National Laboratory phantoms and Monte Carlo method (MCNPX). The results showed, in angiography of right kidney in a child and adult patient, that gall bladder with the amounts of 2.32 and 0.35 mSv, respectively, has received the most equivalent dose. About the physician, left hand, left eye and thymus absorbed the most amounts of doses, means 0.020 mSv. In addition, equivalent doses of the physician's lens eye, thyroid and knees were 0.023, 0.007 and 7.9 - 4 mSv, respectively. Although these values are less than the reported thresholds by ICRP 103, it should be noted that these amounts are related to one examination. (authors)

  20. Accessory Renal Artery Stenosis and Hypertension: Are These Correlated? Evaluation Using Multidetector-Row Computed Tomographic Angiography

    Energy Technology Data Exchange (ETDEWEB)

    Saba, L.; Sanfilippo, R.; Montisci, R.; Conti, M.; Mallarini, G. (Dept. of Imaging Science and Dept. of Vascular Surgery, Policlinico Universitario, Cagliari (Italy))

    2008-04-15

    Background: Renal artery stenosis may produce hypertension, and this condition is referred to as renovascular hypertension (RVH). Purpose: To evaluate, by using multidetector-row spiral computed tomographic angiography (MDCTA), whether a relationship between accessory renal artery stenosis and hypertension may be hypothesized. Material and Methods: 214 patients (142 males, 72 females; mean age 66 years) who had previously undergone an MDCTA to study the abdominal vasculature were retrospectively studied. Patients with renal artery stenosis (RAS) were excluded from this analysis. The patients were studied by means of a four-detector-row CT, and scans were obtained after intravenous bolus administration of 110-140 ml of a nonionic contrast material with a 3-6 ml/s flow rate. As a second step, by means of statistical analysis, hypertension data were compared with findings of accessory artery stenosis. Two radiologists first independently reviewed the MDCTA images and then, in case of disagreement, in consensus. Interobserver agreement was calculated for all measurements. Results: The overall number of detected accessory renal arteries was 74 in 56 of the 214 patients. Accessory renal artery stenosis was detected in 21 of the 56 patients. There was a difference in the prevalence of hypertension between patients with (n = 21) and without (n = 35) accessory renal artery stenosis (P = 0.0187). Interobserver agreement was good (kappa value 0.733). Conclusion: Any statistical association between the presence of accessory renal artery stenosis and hypertension could not be disclosed. However, accessory renal artery stenosis, detected by MDCTA, is an important pathological sign that the radiologist has to assess in the light of its possible association with hypertension

  1. Accessory Renal Artery Stenosis and Hypertension: Are These Correlated? Evaluation Using Multidetector-Row Computed Tomographic Angiography

    International Nuclear Information System (INIS)

    Saba, L.; Sanfilippo, R.; Montisci, R.; Conti, M.; Mallarini, G.

    2008-01-01

    Background: Renal artery stenosis may produce hypertension, and this condition is referred to as renovascular hypertension (RVH). Purpose: To evaluate, by using multidetector-row spiral computed tomographic angiography (MDCTA), whether a relationship between accessory renal artery stenosis and hypertension may be hypothesized. Material and Methods: 214 patients (142 males, 72 females; mean age 66 years) who had previously undergone an MDCTA to study the abdominal vasculature were retrospectively studied. Patients with renal artery stenosis (RAS) were excluded from this analysis. The patients were studied by means of a four-detector-row CT, and scans were obtained after intravenous bolus administration of 110-140 ml of a nonionic contrast material with a 3-6 ml/s flow rate. As a second step, by means of statistical analysis, hypertension data were compared with findings of accessory artery stenosis. Two radiologists first independently reviewed the MDCTA images and then, in case of disagreement, in consensus. Interobserver agreement was calculated for all measurements. Results: The overall number of detected accessory renal arteries was 74 in 56 of the 214 patients. Accessory renal artery stenosis was detected in 21 of the 56 patients. There was a difference in the prevalence of hypertension between patients with (n = 21) and without (n = 35) accessory renal artery stenosis (P = 0.0187). Interobserver agreement was good (kappa value 0.733). Conclusion: Any statistical association between the presence of accessory renal artery stenosis and hypertension could not be disclosed. However, accessory renal artery stenosis, detected by MDCTA, is an important pathological sign that the radiologist has to assess in the light of its possible association with hypertension

  2. Induced renal artery stenosis in rabbits: magnetic resonance imaging, angiography, and radionuclide determination of blood volume and blood flow

    International Nuclear Information System (INIS)

    Mitchell, D.G.; Tobin, M.; LeVeen, R.; Tomaczewski, J.; Alavi, A.; Staum, M.; Kundel, H.

    1988-01-01

    To investigate the ability of MRI to detect alterations due to renal ischemia, a rabbit renal artery stenosis (RAS) model was developed. Seven rabbits had RAS induced by surgically encircling the artery with a polyethylene band which had a lumen of 1 mm, 1 to 2 weeks prior to imaging. The stenosis was confirmed by angiography, and the rabbits were then imaged in a 1.4 T research MRI unit. T1 was calculated using four inversion recovery sequences with different inversion times. Renal blood flow, using 113 Sn-microspheres, and regional water content by drying were then measured. The average T1 of the inner medulla was shorter for the ischemia (1574 msec) than for the contralateral kidney (1849 msec), while no change ws noted in the cortex. Ischemic kidneys had less distinct outer medullary zones on IR images with TI = 600 msec than did contralateral or control kidneys. Blood flow to both the cortex and medulla were markedly reduced in ischemic kidneys compared with contralateral kidneys (119.5 vs. 391 ml/min/100 gm for cortex and 19.8 vs. 50.8 ml/min/100 gm for medulla). Renal water and blood content were less affected. Our rabbit model of renal artery stenosis with MRI, radionuclide, and angiographic correlation has the potential to increase our understanding of MR imaging of the rabbit kidney

  3. The impact of exercise myocardial perfusion SPECT imaging on the selection of patients for coronary angiography

    International Nuclear Information System (INIS)

    Song Liping; He Zuoxiang; Liu Xiujie; Shi Rongfang; Liu Yunzhong; Tian Yueqin; Zhang Xiaoli; Qin Xuewen; Chen Jilin; Gao Runlin

    2001-01-01

    Objective: Exercise 99 Tc m -MIBI myocardial perfusion SPECT is accurate for the diagnosis of coronary artery disease (CAD). This study assessed the impact of exercise myocardial perfusion imaging on the selection of patients for coronary angiography. Methods: 2188 consecutive patients who underwent exercise myocardial perfusion SPECT in authors' department in 1999 were retrospectively analyzed. Among them, 1807 were men, 381 women (average age: 53.5 +- 7.2 years). Overall, exercise myocardial SPECT was normal in 1731 patients, abnormal in 359 cases, and equivocal in 98 patients. There were 141 patients who underwent CAG within 60 days after myocardial SPECT. Results: Overall, 12% of the patients with abnormal SPECT imaging underwent coronary angiography, but only 5% of the patients with a normal SPECT imaging did (P < 0.001). Among these 141 patients who underwent coronary angiography, significant coronary stenosis was present in 91% of the patients who had had an abnormal SPECT imaging, but only 8% of those who had had a normal SPECT imaging (P < 0.001). In those patients who underwent coronary angiography, revascularization rate was 25% for the patients with abnormal SPECT imaging, but only 1% for the patients with a normal SPECT imaging. Conclusion: The results of exercise myocardial perfusion SPECT have a significant impact on the selection of patients for coronary angiography and revascularization

  4. MR-Guided PTA in Experimental Bilateral Rabbit Renal Artery Stenosis and MR Angiography Follow-Up Versus Histomorphometry

    International Nuclear Information System (INIS)

    Le Blanche, Alain-Ferdinand; Rossert, Jerome; Wassef, Michel; Levy, Bernard; Bigot, Jean-Michel; Boudghene, Frank

    2000-01-01

    Purpose: To assess in vivo 1) MR-guided percutaneous transluminal renal angioplasty (PTRA) in experimental bilateral rabbit renal artery stenosis (RAS); 2) postprocedural follow-up by gadolinium-enhanced MR angiography versus histomorphometry.Methods: Fifteen male NZW rabbits of mean weight 4.0 kg (range 3.5-4.2 kg) underwent bilateral RAS induction by combined overdilation-deendothelialization with a gadolinium-filled balloon, passively MR-guided by the artifact of a 0.014-inch guidewire. After 4 weeks the rabbits were randomized into two groups: group A (n = 8) underwent right-sided PTRA for treatment of RAS, group B (n = 7) underwent left-sided PTRA. After another 4 weeks the rabbits were killed to assess by histomorphometry recurrent stenosis and contralateral induction injury stenosis lesions. Each step was preceded by gadolinium-enhanced three-dimensional MR angiography, and the cortex-to-aorta (C/A) signal intensity ratio was calculated.Results: RAS induction was successful in all cases. Fourteen arteries developed restenosis and 13 only initial stenosis. MR-guided PTRAs were feasible in 22 arteries (73%). For a successful catheterization of the ostium (20 arteries, 66% success rate), 10-25 steps were required. Five to eight steps were required for balloon localization and inflation for each PTRA. The restenosis effect was reflected by a 16% (12%-27%) decrease in C/A values on MR angiograms (p < 0.05).Conclusion: MR guidance and MR angiography represent a feasible, less invasive alternative for performing and assessing experimental PTRA in RAS

  5. Intra-arterial digital subtraction angiography in the diagnosis and treatment of renal tumors

    International Nuclear Information System (INIS)

    Yashiro, Naobumi; Itai, Yuji; Iio, Masahiro

    1985-01-01

    Nine patients with renal tumors were studied by IADSA. Embolization was performed in six patients. IADSA were evaluated on the practical points: vascular mapping, visualization of renal veins, and embolization. Vascular mapping with IADSA was satisfactory in eight patients. The limitation of the field of view was the major restricting factor in two. One with multiple renal arteries was unacceptable. Visualization of renal veins by IADSA with renal artery injections was not reliable because of misregistration. Conventional arteriography with large dose was thought to be preferrable. Embolization with IADSA was satisfactory. Significant reduction of contrast load and procedure time was achieved. (author)

  6. Valutazione morfo-funzionale in pazienti ipertesi con stenosi dell'arteria renale; Correlazioni tra angiografia e scintigrafia dinamica. Morpho-functional evaluation in hypertensive patients with renal artery stenosis; Correlations between angiography and radionuclide renography

    Energy Technology Data Exchange (ETDEWEB)

    Cuocolo, A; Celentano, L; Nappi, A [Naples Univ. (Italy). Ist. di Scienze Radiologiche; Neumann, R D; Salvatore, M [Naples Univ. (Italy). Cattedra di Medicina Nucleare

    1991-01-01

    Renovascula hypertension is the most important and common cause of secondary hypertension. We studied 10 patients with arterial hypertension and different degrees of renal artery stenosis to assess the usefulness of dynamic radionuclide renography in evaluating renal perfusion and funcion, and to compare funcional radionuclide results to the morphological findings of renal angiography. Computer-assisted dynamic renal with {sup 00m}Tc diethylenetriaminepentaacetic acid (DTPA) and {sup 131}I orthoiodohippurate (OIH), and renal artheriography were also employed in all patients. In all patients, radionuclide results matched angiography findings in quality. In particular, 3 patients with hemodynamical insignificant renal artery stenosis exhibited normal perfusion and function at dynamic radionuclide renography. Seven patients had significant renal artery stenosis and associated functional changes at dynamic radionuclide renography. Quantitative comparison of all patients showed a significant correlation (r=0.866, p<0.001) between the degree of renal artery stenosis, quantified as the percentage of narrowing as compared to adjacent/contralateral normal vessel diameter, and the results of split renal function, as assessed during OIH studies and expressed per kidney as a percentage of the net total counts of both kidneys. In conclusion, our results demonstrated dynamic radionuclide renography to be a valuable secondary to renal artery stenosis in hypertensive patients, providing complementary results to arteriography.

  7. Efficacy of Patient Selection for Diagnostic Coronary Angiography in Suspected Coronary Artery Disease

    Directory of Open Access Journals (Sweden)

    Francisco Flávio Costa Filho

    2015-11-01

    Full Text Available AbstractBackground:Guidelines recommend that in suspected stable coronary artery disease (CAD, a clinical (non-invasive evaluation should be performed before coronary angiography.Objective:We assessed the efficacy of patient selection for coronary angiography in suspected stable CAD.Methods:We prospectively selected consecutive patients without known CAD, referred to a high-volume tertiary center. Demographic characteristics, risk factors, symptoms and non-invasive test results were correlated to the presence of obstructive CAD. We estimated the CAD probability based on available clinical data and the incremental diagnostic value of previous non-invasive tests.Results:A total of 830 patients were included; median age was 61 years, 49.3% were males, 81% had hypertension and 35.5% were diabetics. Non-invasive tests were performed in 64.8% of the patients. At coronary angiography, 23.8% of the patients had obstructive CAD. The independent predictors for obstructive CAD were: male gender (odds ratio [OR], 3.95; confidence interval [CI] 95%, 2.70 - 5.77, age (OR for 5 years increment, 1.15; CI 95%, 1.06 - 1.26, diabetes (OR, 2.01; CI 95%, 1.40 - 2.90, dyslipidemia (OR, 2.02; CI 95%, 1.32 - 3.07, typical angina (OR, 2.92; CI 95%, 1.77 - 4.83 and previous non-invasive test (OR 1.54; CI 95% 1.05 - 2.27.Conclusions:In this study, less than a quarter of the patients referred for coronary angiography with suspected CAD had the diagnosis confirmed. A better clinical and non-invasive assessment is necessary, to improve the efficacy of patient selection for coronary angiography.

  8. MR angiography with Vasovist

    Energy Technology Data Exchange (ETDEWEB)

    Goyen, Mathias [University Medical Center Hamburg-Eppendorf, Martinistrasse 52, 20251 Hamburg (Germany)], E-mail: goyen@uke.uni-hamburg.de

    2007-12-15

    Vasovist (Gadofosveset) is the first intravascular contrast agent approved for use with magnetic resonance angiography in the European Union. This blood pool contrast agent reversibly binds to albumin providing extended intravascular enhancement compared to existing extracellular magnetic resonance contrast agents. Prior to approval, Vasovist underwent extensive clinical and pre-clinical testing to evaluate the safety and efficacy of the drug. The clinical trials program included blinded, placebo-controlled dose ranging, efficacy in a variety of vascular beds (aorto-iliac, renal, pedal), examination of potential drug interaction with warfarin, and comparison with X-ray angiography. The clinical trials show that Vasovist-enhanced MR angiography is safe and well tolerated in patients with vascular disease, effective for the detection of vascular stenosis and aneurysms, significantly more accurate (both more sensitive and specific) than non-contrast MR angiography for the diagnosis of vascular stenoses, and similar to conventional angiography for the overall characterization of vascular disease, without the need for catheterization. This review article highlights the product characteristics of Vasovist, gives an overview of the clinical development program and discusses selected clinical applications.

  9. MR angiography with Vasovist

    International Nuclear Information System (INIS)

    Goyen, Mathias

    2007-01-01

    Vasovist (Gadofosveset) is the first intravascular contrast agent approved for use with magnetic resonance angiography in the European Union. This blood pool contrast agent reversibly binds to albumin providing extended intravascular enhancement compared to existing extracellular magnetic resonance contrast agents. Prior to approval, Vasovist underwent extensive clinical and pre-clinical testing to evaluate the safety and efficacy of the drug. The clinical trials program included blinded, placebo-controlled dose ranging, efficacy in a variety of vascular beds (aorto-iliac, renal, pedal), examination of potential drug interaction with warfarin, and comparison with X-ray angiography. The clinical trials show that Vasovist-enhanced MR angiography is safe and well tolerated in patients with vascular disease, effective for the detection of vascular stenosis and aneurysms, significantly more accurate (both more sensitive and specific) than non-contrast MR angiography for the diagnosis of vascular stenoses, and similar to conventional angiography for the overall characterization of vascular disease, without the need for catheterization. This review article highlights the product characteristics of Vasovist, gives an overview of the clinical development program and discusses selected clinical applications

  10. Venous digital subtraction angiography of the renal arteries in hypertensive patients

    International Nuclear Information System (INIS)

    Brecht, G.; Harder, T.; Franken, T.

    1984-01-01

    We carried out 1890 venous digital subtraction angiograms; this included 113 patients with hypertension in order to exclude renal artery stenosis. On four occasions it was used following surgery on a renal artery. Renal artery stenosis or occlusion was demonstrated in twelve patients, and other vascular diseases or anomalies were found in 24. Two abnormal renal arteries were found following renal artery surgery. The results are compared with smaller groups of patients examined by DSA, and with the results of conventional subtraction methods reported in the literature. In only eight patients (6.8%) DSA provided insufficient information and had to be supplemented by aortography. The method has proved to be a valuable and simple screening method for the investigation of hypertension. (orig.) [de

  11. Late haemodynamic response to metrizamide and ioxaglate in canine renal angiography

    International Nuclear Information System (INIS)

    Satokari, K.; Kivisaari, A.; Virtama, P.

    1981-01-01

    The renal blood flow was examined in six dogs for 2 h after contrast agent injection into the renal artery using the dye dilution method. After injection of an ionic contrast agent (iodamide) there was an initial vasodilatation and later constriction, but the blood flow was back to normal after 10-15 min. Ioxaglate caused a similar initial response, but after a relatively large dose the blood flow remained below normal for 2 h. Metrizamide caused an immediate reduction in the blood flow, which remained constantly reduced for 2 h. A total cessation of the renal blood flow was seen in two cases. (orig.) [de

  12. Angiographic analysis of avascular necrosis of a femoral head -selective angiography of medial femoral circumflex artery-

    Energy Technology Data Exchange (ETDEWEB)

    Ryu, Kyung Nam; Yoon, Yup; Lee, Sun Wha; Lim, Jae Hoon [Kyung Hee University Hospital, Seoul (Korea, Republic of)

    1991-07-15

    The degree of anatomical revascularization of a necrotic femoral head and traumatic hip would provide information about treatment and prognosis. The authors analyzed the vascular changes of femoral head among unilateral avascular necrosis, bilateral avascular necrosis, and traumatic hips. Forty - four patients with avascular necrosis and 19 patients with traumatic hips were examined by selective angiography of the medial femoral circumflex artery. In the traumatic hip cases, 12 (63%) showed occlusion, 2 (11%) hypertrophy of the capsular branches, and 5 ( 26 % ) were normal . In the avascular necrosis cases, 15 (25%) showed occlusion, 39 (67%) had hypertrophy of the capsular branches, and 4 (7%) had normal findings. Hypertrophy of the superior capsular branch of the medial femoral circumflex artery is more frequently observed in avascular necrosis than in traumatic hip. Bilateral avascular necrosis reveals more frequent incidences than unilateral cases. Selective angiography could help in the therapy plan and also provide information about the contralateral side.

  13. Angiographic analysis of avascular necrosis of a femoral head -selective angiography of medial femoral circumflex artery-

    International Nuclear Information System (INIS)

    Ryu, Kyung Nam; Yoon, Yup; Lee, Sun Wha; Lim, Jae Hoon

    1991-01-01

    The degree of anatomical revascularization of a necrotic femoral head and traumatic hip would provide information about treatment and prognosis. The authors analyzed the vascular changes of femoral head among unilateral avascular necrosis, bilateral avascular necrosis, and traumatic hips. Forty - four patients with avascular necrosis and 19 patients with traumatic hips were examined by selective angiography of the medial femoral circumflex artery. In the traumatic hip cases, 12 (63%) showed occlusion, 2 (11%) hypertrophy of the capsular branches, and 5 ( 26 % ) were normal . In the avascular necrosis cases, 15 (25%) showed occlusion, 39 (67%) had hypertrophy of the capsular branches, and 4 (7%) had normal findings. Hypertrophy of the superior capsular branch of the medial femoral circumflex artery is more frequently observed in avascular necrosis than in traumatic hip. Bilateral avascular necrosis reveals more frequent incidences than unilateral cases. Selective angiography could help in the therapy plan and also provide information about the contralateral side

  14. Abdominal MR angiography

    International Nuclear Information System (INIS)

    Wegmueller, H.; Vock, P.

    1993-01-01

    The two techniques currently most often used for MR angiography, those based on time-of-flight effects and on phase-contrast, are introduced, and our results with three-dimensional phase contrast angiography of the abdomen are presented. Several basic differences from other imaging procedures render MR angiography clinically useful for screening for renal artery stenosis in critical situations, such as renal failure or intolerance to contrast agents. In the future, the spectrum of applications of MR angiography will broaden and include other indications, such as portal venous hypertension and follow-up studies after surgical portal systemic shunting. (orig.) [de

  15. Role of high resolution contrast-enhanced magnetic resonance angiography (HR CeMRA) in management of arterial complications of the renal transplant

    International Nuclear Information System (INIS)

    Ismaeel, M. Maged; Abdel-Hamid, Azza

    2011-01-01

    Introduction: Transplant renal artery (RA) stenosis (TRAS) is the most frequent posttransplantation vascular complication. Contrast enhanced magnetic resonance (CeMRA) angiography has been established as the preferred imaging technique for the evaluation of TRAS because it does not require the use of iodinated contrast material and does not expose the patient to ionizing radiation. Digital subtraction angiography (DSA) is the gold standard in the evaluation of arterial tree of the renal allograft. Aim of the work: This study was carried out to assess the accuracy of CeMRA in the detection of arterial complications after renal transplantation. Patients and methods: Thirty renal transplant patients with suspected arterial complications in which both CeMRA and DSA were performed were included in the study. The HR CeMRA shows 93.7% sensitivity, 80% specificity, 88.2% positive predictive value, 88.9% negative predictive value and 88.5% accuracy. Conclusion: HR CeMRA is an accurate reliable tool in the assessment of arterial complications after renal transplantation. It may replace DSA as a diagnostic modality with reservation of interventional techniques for endovascular treatment of suitable cases.

  16. Role of high resolution contrast-enhanced magnetic resonance angiography (HR CeMRA) in management of arterial complications of the renal transplant

    Energy Technology Data Exchange (ETDEWEB)

    Ismaeel, M. Maged [Suez Canal University (Egypt); Abdel-Hamid, Azza, E-mail: azza4951@hotmail.com [Suez Canal University (Egypt)

    2011-08-15

    Introduction: Transplant renal artery (RA) stenosis (TRAS) is the most frequent posttransplantation vascular complication. Contrast enhanced magnetic resonance (CeMRA) angiography has been established as the preferred imaging technique for the evaluation of TRAS because it does not require the use of iodinated contrast material and does not expose the patient to ionizing radiation. Digital subtraction angiography (DSA) is the gold standard in the evaluation of arterial tree of the renal allograft. Aim of the work: This study was carried out to assess the accuracy of CeMRA in the detection of arterial complications after renal transplantation. Patients and methods: Thirty renal transplant patients with suspected arterial complications in which both CeMRA and DSA were performed were included in the study. The HR CeMRA shows 93.7% sensitivity, 80% specificity, 88.2% positive predictive value, 88.9% negative predictive value and 88.5% accuracy. Conclusion: HR CeMRA is an accurate reliable tool in the assessment of arterial complications after renal transplantation. It may replace DSA as a diagnostic modality with reservation of interventional techniques for endovascular treatment of suitable cases.

  17. Parametric Imaging Of Digital Subtraction Angiography Studies For Renal Transplant Evaluation

    Science.gov (United States)

    Gallagher, Joe H.; Meaney, Thomas F.; Flechner, Stuart M.; Novick, Andrew C.; Buonocore, Edward

    1981-11-01

    A noninvasive method for diagnosing acute tubular necrosis and rejection would be an important tool for the management of renal transplant patients. From a sequence of digital subtraction angiographic images acquired after an intravenous injection of radiographic contrast material, the parametric images of the maximum contrast, the time when the maximum contrast is reached, and two times the time at which one half of the maximum contrast is reached are computed. The parametric images of the time when the maximum is reached clearly distinguish normal from abnormal renal function. However, it is the parametric image of two times the time when one half of the maximum is reached which provides some assistance in differentiating acute tubular necrosis from rejection.

  18. Renal MR angiography and perfusion in the pig using hyperpolarized water

    DEFF Research Database (Denmark)

    Lipsø, Hans Kasper Wigh; Hansen, Esben Søvsø Szocska; Tougaard, Rasmus Stilling

    2016-01-01

    at 3 Tesla (T). Approximately 15 mL of hyperpolar-ized water was injected in the renal artery by hand over 4–5 s.Results: A liquid state polarization of 5.3 6 0.9% of 3.8 M pro-tons in 15 mL of deuterium oxide was achieved with a T1of24 6 1 s. This allowed injection through an arterial catheterinto...

  19. Asymmetry of renal blood flow in patients with moderate to severe hypertension

    NARCIS (Netherlands)

    van Onna, Marieke; Houben, Alphons J. H. M.; Kroon, Abraham A.; Wierema, Thomas K. A.; Koster, Derk; van Engelshoven, Jos M. A.; de Leeuw, Peter W.

    2003-01-01

    It is generally assumed that renal blood flow is symmetric in the absence of renal artery stenosis. The aim of the present study was to evaluate whether this is really the case. From a group of consecutive hypertensive patients who had undergone renal angiography, we selected those with patent renal

  20. Renal Artery Stenosis Evaluated with 3D-Gd-Magnetic Resonance Angiography Using Transstenotic Pressure Gradient as the Standard of Reference. A Multireader Study

    International Nuclear Information System (INIS)

    Ekloef, H.; Ahlstrom, H.; Bostrom, A.; Bergqvist, D.; Andren, B.; Karacagil, S.; Nyman, R.

    2005-01-01

    Purpose: To evaluate 3D-Gd-magnetic resonance angiography (MRA) in detecting hemodynamically significant renal artery stenosis (RAS). Material and Methods: Thirty patients evaluated for atherosclerotic RAS by MRA and digital subtraction angiography (DSA) were retrospectively included. Standard of reference for hemodynamically significant RAS was a transstenotic gradient of 15 mmHg. DSA visualized 60 main renal arteries and 9 accessory arteries. Pressure gradient measurement (PGM) was available from 61 arteries. Three radiologists evaluated all examinations independently in a blinded fashion. Results: RAS was present in 26 arteries. On MRA, each reader identified 4 of 9 accessory renal arteries, a detection rate of 44%. The three readers correctly classified 22/25/22 of the 26 vessels with a significant gradient as >60% RAS and 31/25/32 of the 35 with a significant gradient as <60% RAS on MRA. Interobserver agreement was substantial. MRA image quality was adequate for RAS evaluations in all patients. ROC curves indicated that MRA is an adequate method for evaluating RAS. When screening for RAS, a 50% diameter reduction cut-off is better than 60%. RAS with 40-80% diameter reductions accounted for 65% of discrepancies. Conclusion: MRA is an adequate method for evaluating RAS limited mainly by poor detection rate for accessory renal arteries

  1. Selective intra-arterial digital subtraction angiography (IADSA) in cerebrovascular disease

    International Nuclear Information System (INIS)

    Uchino, Akira; Satoh, Yoshiyuki; Ohno, Masato

    1987-01-01

    Selective right transbrachial intra-arterial digital subtraction angiography (transbrachial selective IADSA) was successfully performed for 24 of 26 patients with known or suspected cerebrovascular disease, four of whom were outpatients. Catheterization failed in two elderly hypertensive men because of tortuosity of their brachial arteries, and in one woman whose aberrant right subclavian artery (SCA) prevented bilateral common carotid arterial (CCA) catheterizations. No complications occurred. One-hundred and ten ''excellent'' images were obtained by means of 118 injections for the 24 patients. Iopamidol, the contrast medium, was diluted to 50 % concentration with saline, then warmed to 37 deg C. Nearly all the injections of both CCAs and right vertebral arteries (VAs) were completed using 10 ml injections and a 5 ml/sec flow rate. The mean examination time for the three-vessel study was 29.4 minutes. Transbrachial selective IADSA thus proved to be a safe, useful, and relatively easy means of diagnosing cerebrovascular disease. (author)

  2. Preoperative evaluation of living renal donors: value of contrast-enhanced 3D magnetic resonance angiography and comparison of three rendering algorithms

    International Nuclear Information System (INIS)

    Fink, C.; Hallscheidt, P.J.; Hosch, W.P.; Kauffmann, G.W.; Duex, M.; Ott, R.C.; Wiesel, M.

    2003-01-01

    The aim of this study was to assess the value of contrast-enhanced three-dimensional MR angiography (CE 3D MRA) in the preoperative assessment of potential living renal donors, and to compare the accuracy for the depiction of the vascular anatomy using three different rendering algorithms. Twenty-three potential living renal donors were examined with CE 3D MRA (TE/TR=1.3 ms/3.7 ms, field of view 260-320 x 350 mm, 384-448 x 512 matrix, slab thickness 9.4 cm, 72 partitions, section thickness 1.3 mm, scan time 24 s, 0.1 mmol/kg body weight gadobenate dimeglumine). Magnetic resonance angiography data sets were processed with maximum intensity projection (MIP), volume rendering (VR), and shaded-surface display (SSD) algorithms. The image analysis was performed independently by three MR-experienced radiologists recording the number of renal arteries, the presence of early branching or vascular pathology. The combination of digital subtraction angiography (DSA) and intraoperative findings served as the gold standard for the image analysis. In total, 52 renal arteries were correspondingly observed in 23 patients at DSA and surgery. Other findings were 3 cases of early branching of the renal arteries, 4 cases of arterial stenosis and 1 case of bilateral fibromuscular dysplasia. With MRA source data all 52 renal arteries were correctly identified by all readers, compared with 51 (98.1%), 51-52 (98.1-100%) and 49-50 renal arteries (94.2-96.2%) with the MIP, VR and SSD projections, respectively. Similarly, the sensitivity, specificity and accuracy was highest with the MRA source data followed by MIP, VR and SSD. Time requirements were lowest for the MIP reconstructions and highest for the VR reconstructions. Contrast-enhanced 3D MRA is a reliable, non-invasive tool for the preoperative evaluation of potential living renal donors. Maximum intensity projection is favourable for the processing of 3D MRA data, as it has minimal time and computational requirements, while having

  3. Preoperative evaluation of living renal donors: value of contrast-enhanced 3D magnetic resonance angiography and comparison of three rendering algorithms

    Energy Technology Data Exchange (ETDEWEB)

    Fink, C. [Abteilung Radiologische Diagnostik, Radiologische Universitaetsklinik Heidelberg, Im Neuenheimer Feld 110, 69120 Heidelberg (Germany); Abteilung Onkologische Diagnostik und Therapie, Forschungsschwerpunkt Radiologische Diagnostik und Therapie, Deutsches Krebsforschungszentrum, Im Neuenheimer Feld 280, 69120 Heidelberg (Germany); Hallscheidt, P.J.; Hosch, W.P.; Kauffmann, G.W.; Duex, M. [Abteilung Radiologische Diagnostik, Radiologische Universitaetsklinik Heidelberg, Im Neuenheimer Feld 110, 69120 Heidelberg (Germany); Ott, R.C.; Wiesel, M. [Abteilung Urologie und Poliklinik, Chirurgische Universitaetsklinik Heidelberg, Im Neuenheimer Feld 110, 69120 Heidelberg (Germany)

    2003-04-01

    The aim of this study was to assess the value of contrast-enhanced three-dimensional MR angiography (CE 3D MRA) in the preoperative assessment of potential living renal donors, and to compare the accuracy for the depiction of the vascular anatomy using three different rendering algorithms. Twenty-three potential living renal donors were examined with CE 3D MRA (TE/TR=1.3 ms/3.7 ms, field of view 260-320 x 350 mm, 384-448 x 512 matrix, slab thickness 9.4 cm, 72 partitions, section thickness 1.3 mm, scan time 24 s, 0.1 mmol/kg body weight gadobenate dimeglumine). Magnetic resonance angiography data sets were processed with maximum intensity projection (MIP), volume rendering (VR), and shaded-surface display (SSD) algorithms. The image analysis was performed independently by three MR-experienced radiologists recording the number of renal arteries, the presence of early branching or vascular pathology. The combination of digital subtraction angiography (DSA) and intraoperative findings served as the gold standard for the image analysis. In total, 52 renal arteries were correspondingly observed in 23 patients at DSA and surgery. Other findings were 3 cases of early branching of the renal arteries, 4 cases of arterial stenosis and 1 case of bilateral fibromuscular dysplasia. With MRA source data all 52 renal arteries were correctly identified by all readers, compared with 51 (98.1%), 51-52 (98.1-100%) and 49-50 renal arteries (94.2-96.2%) with the MIP, VR and SSD projections, respectively. Similarly, the sensitivity, specificity and accuracy was highest with the MRA source data followed by MIP, VR and SSD. Time requirements were lowest for the MIP reconstructions and highest for the VR reconstructions. Contrast-enhanced 3D MRA is a reliable, non-invasive tool for the preoperative evaluation of potential living renal donors. Maximum intensity projection is favourable for the processing of 3D MRA data, as it has minimal time and computational requirements, while having

  4. Hemodynamic Measurements for the Selection of Patients With Renal Artery Stenosis: A Systematic Review.

    Science.gov (United States)

    van Brussel, Peter M; van de Hoef, Tim P; de Winter, Robbert J; Vogt, Liffert; van den Born, Bert-Jan

    2017-05-22

    Interventions targeting renal artery stenoses have been shown to lower blood pressure and preserve renal function. In recent studies, the efficacy of catheter-based percutaneous transluminal renal angioplasty with stent placement has been called into question. In the identification of functional coronary lesions, hyperemic measurements have earned a place in daily practice for clinical decision making, allowing discrimination between solitary coronary lesions and diffuse microvascular disease. Next to differences in clinical characteristics, the selection of renal arteries suitable for intervention is currently on the basis of anatomic grading of the stenosis by angiography rather than functional assessment under hyperemia. It is conceivable that, like the coronary circulation, functional measurements may better predict therapeutic efficacy of percutaneous transluminal renal angioplasty with stent placement. In this systematic review, the authors evaluate the available clinical evidence on the optimal hyperemic agents to induce intrarenal hyperemia, their association with anatomic grading, and their predictive value for treatment effects. In addition, the potential value of combined pressure and flow measurements to discriminate macrovascular from microvascular disease is discussed. Copyright © 2017 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.

  5. Catheter Angiography

    Medline Plus

    Full Text Available ... News Physician Resources Professions Site Index A-Z Catheter Angiography Catheter angiography uses a catheter, x-ray ... are the limitations of Catheter Angiography? What is Catheter Angiography? Angiography is a minimally invasive medical test ...

  6. Renal Infarction Caused by Spontaneous Renal Artery Dissection: Treatment with Catheter-Directed Thrombolysis and Stenting

    International Nuclear Information System (INIS)

    Jeon, Yong Sun; Cho, Soon Gu; Hong, Ki Cheon

    2009-01-01

    Spontaneous renal artery dissection (SRAD) is rare and presents a diagnostic and therapeutic challenge. We report a case of a 36-year-old man who had an SRAD-complicated renal infarction. The patient experienced severe unilateral flank pain. Enhanced abdominal computed axial tomography scan showed renal infarction, and urinalysis showed no hematuria. Selective renal angiography was essential to evaluate the extent of dissection and suitability for repair. The patient was treated with catheter-directed thrombolysis and frenal artery stenting.

  7. Angiography and interventional radiology of the kidneys

    International Nuclear Information System (INIS)

    Hansmann, J.; Richter, G.M.; Hallscheidt, P.; Duex, M.; Noeldge, G.; Kaufmann, G.W.

    1999-01-01

    For imaging of renal pathology a broad spectrum of radiologic diagnostic procedures are available which are, sometimes and particularly more recently, competing among each other in their diagnostic yield and relevance. For tumorous lesions ultrasound, computed tomography and magnetic resonance imaging are performed predominantly. Angiography is no longer required with the exception of highly selected cases and in some specific preoperative workup requirements. Until recently, catheter based digital subtraction angiography has been considered as gold standard. However, non-invasive techniques such as CT-angiography and MR-angiography are evolving parallel to their quantum leap of resolutions and readiness to use. Nevertheless, well accepted criteria for quality assessement of these new modalities are still lacking. More comparison studies are urgently warranted. Despite the availability of ultrashort pulse sequences applying the T1 relaxation reduction effect of gadolinium enhanced MR techniques overestimation of renal artery stenosis still poses a substantial problem. Renal intervention implies a variety of procedures such as plain angioplasty, stent placement, embolization of traumatic and both benign and malignant tumors. These methods have emerged over the last two decades from a more experimental nature to a fully accepted treatment option. When renal artery angioplasty is embedded in an aggressive approach including stenting as an adjunct for more complex cases, renal ostial lesions and a well organized follow-up regimen its therapeutic potential for treatment of renal insufficiency, malignant hypertension, for organ preservation bears a very high potential. Provided adequate periinterventional drug regimen restenosis rates may be as low as 10%. In highly selected cases capillary embolization might be used as an alternative to nephrectomy with a similar clinical outcome. Particularly the development of superselective small caliber embolization catheters

  8. Radionuclide angiography

    Energy Technology Data Exchange (ETDEWEB)

    Heidenreich, P; Klotz, E

    1983-12-27

    RNA of common and internal carotid arteries as well as main cerebral arteries is the first component of cerebral serial scintigraphy. It should be the first diagnostic step in suspected cerebrovascular disease. In contrast to computed tomography RNA gives valuable information about cerebrovascular processes without morphological defects. RNA is superior of Doppler sonography in the evaluation of intracranial vascular disease. The simple and non-invasive RNA of the kidneys should be performed after renal transplantation (i.e. differential diagnosis of acute rejection and acute tubular necrosis), in suspected renal artery stenosis, renal infarction or in arterio-venous malformation of the kidneys. RNA is valuable in suspected occlusion of the abdominal aorta (infra- or suprarenal), aortic aneurysm or in stenosis of arteries in the pelvis or thighs. Postoperative controls can be carried out as often as desired. However, it cannot replace contrast angiography if vascular reconstruction is planned.

  9. Protective effects of losartan in renal dysfunction during coronary angiography and intervention caused by low osmolar non-ionic contrast media

    International Nuclear Information System (INIS)

    Chen Yueguang; Zhang Dadong; Gu Jun; Song Zhiping; Yu Qiang; Feng Xiaodi; Xiao Hongbing; Yin Guizhi; Guan Ping; Chen Chengjun; Yang Hui; Jin Xian; Dong Jian; Fan Xiaomin

    2007-01-01

    Objective: To observe the changes of renal function during simple coronary angiography (CAG)and pereutaneous coronary intervention (PCI)caused by low osmolar non-ionic contrast media and to evaluate the preventive effect of losartan on renal function(serum creatinine)in PCI. Methods: All 171 cases were divided into 3 groups, CAG negative group(N=73), PCI group (N=52)and treatment group (PCI + Losartan, N=46)according to the results given by coronary arteriography. The investigation was performed on the influences produced by the low osmolar non-ionic contrast medium(Ioversol)on renal function and minimal albumin proteinuria in the 3 groups. The minimal albumin proteinuria and renal function (serum creatinine) were tested before and 1 d, 3 d, 7 d after the procedure and followed by the comparison and evaluation of the outcoming data. Results: There were no significant changes of serum creatinine among 3 groups, but amount of minimal albumin proteinuria was increased in PCI group (P<0.05), and decreased obviously after Losartan medication (P<0.05). Conclusion: Low ormolar non-ionic contrast media produce no significant influence on renal function (serum creatinine)during CAG and/or PCI but with different degrees of increase for minimal albumin proteinuria, especially in PCI group. Losartan can decrease minimal albumin proteinuria after PCI procedure, possibly providing the prevention for contrast medium induced nephropathy. (authors)

  10. Assessment of renal artery stenosis of transplanted kidney by time resolved gadolinium-enhanced three-dimensional MR angiography. Preliminary phantom study and clinical evaluation

    International Nuclear Information System (INIS)

    Hayano, Toshio

    2001-01-01

    The purpose of this study was to determine a suitable imaging parameters of time-resolved Gd-enhanced three-dimensional MR angiography (TRE3DMRA) for the evaluation of renal artery stenosis of transplanted kidneys and to investigate the usefulness of TRE3DMRA in 166 clinical cases. Source images were obtained 3dFLASH with zero-filling interpolation (turbo MRA) using Siemens Magneton 1.5T. Acrylate tubes with 6 mm inner diameter filled with diluted Gd-DTPA were used as special phantoms. In the tubes, 25%, 50%, and 75% stenosis were made for simulating arterial stenosis, respectively. According to our clinical experiences, we decided 10 seconds or less acquisition time to obtaining renal artery images without overlapping with renal veins. To determine slice thickness, the degrees of stenosis of the phantom images obtained 8-second acquisition time in variable slice thickness were independently interpreted with visual inspection by two experienced diagnostic radiologists. One hundred sixty-six patients underwent renal transplantation were evaluated clinically. Using a power injector, 0.1 mmol/kg Gd-DTPA was injected after the test scan with 1 ml Gd-DTPA for the determination of acquisition timing. MR images were obtained in the following imaging parameters; 4-mm slice thickness and 8-second acquisition time based on the results of phantom studies. Source images were noted in oblique coronal direction encompassing the entire renal arteries from iliac arteries to renal hili. Based on phantom study, slice thickness must be less than 4-mm to demonstrate the significant stenotic portion (>50%) of the phantom simulating transplanted renal artery. In 150 of 166 patients, excellent images of renal arteries were obtained without overlapping with renal veins. Causes of poor images were mainly inadequate timing of image acquisition. We can decide the imaging parameters of TRE3DMRA for the evaluation of renal artery stenosis of transplanted kidneys. Using these parameters, in 150

  11. Improvement of chemical shift selective saturation (CHESS) pulse for MR angiography

    International Nuclear Information System (INIS)

    Ishimori, Yoshiyuki; Sashie, Hiroyuki; Hiraga, Akira; Matsuda, Tsuyoshi

    2000-01-01

    We improved the fat suppression technique based on chemical shift selective saturation (CHESS). To do this, we shortened the duration of the CHESS pulse to achieve a short repetition time (TR) for MR angiography (MRA). A short-duration CHESS pulse causes broad frequency band saturation, creating extensive offset from the resonance frequency of water. In our phantom experiment, the best parameters of the short-duration CHESS pulse were 3.84 ms in duration, -650 Hz in offset frequency from water resonance, and had a 130-degree flip angle. With this technique, MRA will be able to be carried out without a significant increase in TR. Thus, better vessel contrast will be maintained in time-of-flight (TOF) MRA or contrast-enhanced MRA when using the maximum intensity projection (MIP) method. (author)

  12. Usefulness of selective cerebral intra-arterial digital subtraction angiography by transbrachial approach

    International Nuclear Information System (INIS)

    Matsunaga, Naofumi; Hayashi, Kuniaki; Uetani, Masataka; Hirao, Koichi; Fukuda, Toshio; Aikawa, Hisayuki; Iwao, Masaaki; Hombo, Zen-ichiro

    1988-01-01

    Selective cerebral intra-arterial digital subtraction angiography (IA-DSA) by the transbrachial approach was performed on 53 patients (including 34 outpatients) with suspected cerebrovascular diseases or brain tumors. 80-cm-long, 4F modified Simmons catheter was used. Success rates of selective catheterization to the common carotid and vertebral arteries were 86.0 % from right transbrachial approach (35 cases) and 79.6 % from left approach (18 cases). Successful catheterization to the common carotid and ipsilateral vertebral arteries is obtained in 91.3 % from right transbrachial approach, and 78.7 % from left approach. Righ common carotid artery could be catheterized in all 55 cases from right transbrachial approach, but in only 6 of 15 patients (40 %) from left approach. As for contrast material, 4 or 6 ml of Iopamidol 300 mgI/ml were mechanically injected into common carotid artery at a flow rate of 2 - 3 ml/sec, and 9 ml two-fold diluted Iopamidol were injected into the vertebral artery at a flow rate of 6 ml/sec. There was no recoil of the catheter. Visualization of the relatively small vessels such as cortical branches was excellent in most cases. However, smaller vessel such as meningohypophyseal trunk was not well visualized with IA-DSA. Spatial resolution of IA-DSA was generally satisfactory. However, conventional angiography was still required, particularly to clearly delineate small cerebral aneurysms. Major complications were never experienced. It was concluded that this procedure is useful, particularly for the screening and postoperative follow-up studies, and can also be applied to outpatients. (author)

  13. Angiography and interventional radiology of the kidneys; Angiographie und interventionelle Radiologie der Nieren

    Energy Technology Data Exchange (ETDEWEB)

    Hansmann, J.; Richter, G.M.; Hallscheidt, P.; Duex, M.; Noeldge, G.; Kaufmann, G.W. [Heidelberg Univ. (Germany). Abt. Radiodiagnostik

    1999-05-01

    For imaging of renal pathology a broad spectrum of radiologic diagnostic procedures are available which are, sometimes and particularly more recently, competing among each other in their diagnostic yield and relevance. For tumorous lesions ultrasound, computed tomography and magnetic resonance imaging are performed predominantly. Angiography is no longer required with the exception of highly selected cases and in some specific preoperative workup requirements. Until recently, catheter based digital subtraction angiography has been considered as gold standard. However, non-invasive techniques such as CT-angiography and MR-angiography are evolving parallel to their quantum leap of resolutions and readiness to use. Nevertheless, well accepted criteria for quality assessement of these new modalities are still lacking. More comparison studies are urgently warranted. Despite the availability of ultrashort pulse sequences applying the T1 relaxation reduction effect of gadolinium enhanced MR techniques overestimation of renal artery stenosis still poses a substantial problem. Renal intervention implies a variety of procedures such as plain angioplasty, stent placement, embolization of traumatic and both benign and malignant tumors. These methods have emerged over the last two decades from a more experimental nature to a fully accepted treatment option. When renal artery angioplasty is embedded in an aggressive approach including stenting as an adjunct for more complex cases, renal ostial lesions and a well organized follow-up regimen its therapeutic potential for treatment of renal insufficiency, malignant hypertension, for organ preservation bears a very high potential. Provided adequate periinterventional drug regimen restenosis rates may be as low as 10%. In highly selected cases capillary embolization might be used as an alternative to nephrectomy with a similar clinical outcome. Particularly the development of superselective small caliber embolization catheters

  14. Effect of selective inhibition of renal inducible nitric oxide synthase on renal blood flow and function in experimental hyperdynamic sepsis.

    Science.gov (United States)

    Ishikawa, Ken; Calzavacca, Paolo; Bellomo, Rinaldo; Bailey, Michael; May, Clive N

    2012-08-01

    Nitric oxide plays an important role in the control of renal blood flow and renal function. In sepsis, increased levels of inducible nitric oxide synthase produce excessive nitric oxide, which may contribute to the development of acute kidney injury. We, therefore, examined the effects of intrarenal infusion of selective inducible nitric oxide synthase inhibitors in a large animal model of hyperdynamic sepsis in which acute kidney injury occurs in the presence of increased renal blood flow. Prospective crossover randomized controlled interventional studies. University-affiliated research institute. Twelve unilaterally nephrectomized Merino ewes. Infusion of a selective (1400W) and a partially selective inducible nitric oxide synthase inhibitor (aminoguanidine) into the renal artery for 2 hrs after the induction of sepsis, and comparison with a nonselective inhibitor (Nω-nitro-L-arginine methyl ester). In sheep with nonhypotensive hyperdynamic sepsis, creatinine clearance halved (32 to 16 mL/min, ratio [95% confidence interval] 0.51 [0.28-0.92]) despite increased renal blood flow (241 to 343 mL/min, difference [95% confidence interval] 102 [78-126]). Infusion of 1400W did not change renal blood flow, urine output, or creatinine clearance, whereas infusion of Nω-nitro-L-arginine methyl ester and a high dose of aminoguanidine normalized renal blood flow, but did not alter creatinine clearance. In hyperdynamic sepsis, intrarenal infusion of a highly selective inducible nitric oxide synthase inhibitor did not reduce the elevated renal blood flow or improve renal function. In contrast, renal blood flow was reduced by infusion of a nonselective NOS inhibitor or a high dose of a partially selective inducible nitric oxide synthase inhibitor. The renal vasodilatation in septic acute kidney injury may be due to nitric oxide derived from the endothelial and neural isoforms of nitric oxide synthase, but their blockade did not restore renal function.

  15. Multidetector row CT angiography of living related renal donors: Is there a need for venous phase imaging?

    International Nuclear Information System (INIS)

    Namasivayam, Saravanan; Kalra, Mannudeep K.; Waldrop, Sandra M.; Mittal, Pardeep K.; Small, William C.

    2006-01-01

    Objective: To prospectively evaluate whether renal venous anatomy can be detected from arterial phase images of multidetector row CT (MDCT) of renal donors. Material and methods: Institutional review board approved our study protocol with waiver of consent. Forty-eight consecutive renal donors (age range, 21-56 years; M:F, 20:28) referred for MDCT evaluation were included. Two sub-specialty radiologists performed an independent and separate evaluation of renal venous anatomy in arterial and venous phase images. Opacification of renal venous structures was scored on a five-point scale (1-not seen; 3-minimal opacification; 5-excellent opacification). Arterial and venous phase opacification scores were compared by Wilcoxon signed rank test. Results: Both readers detected all renal venous anomalies in arterial as well as venous phase images. Each reader detected accessory right renal veins (n = 14), retroaortic left renal vein (n = 2), circumaortic left renal vein (n = 1), and left renal hilar arteriovenous malformation (n = 1) in arterial phase images. Retroaortic left renal venous branch was difficult to differentiate from lumbar vein (reader-1, n = 1; reader-2, n = 2) in both arterial and venous phase images. Sensitivity of detection of renal veins, left adrenal, gonadal and lumbar veins in arterial phase images was 100, 83-88, 100, and 85-90%, respectively. As expected, venous phase images showed significantly greater opacification of renal veins, left gonadal, adrenal and lumbar veins (p < .05). However, this did not substantially limit the evaluation of renal venous anatomy in arterial phase images. Both readers had substantial interobserver agreement (kappa coefficient, 0.7; p < 0.05). Conclusions: Arterial phase MDCT images alone can be used to detect renal venous anomalies, and to identify small left renal venous branches namely, the left gonadal, adrenal and lumbar veins in renal donors. Venous phase MDCT acquisition is not necessary for evaluation of renal

  16. Multidetector row CT angiography of living related renal donors: Is there a need for venous phase imaging?

    Energy Technology Data Exchange (ETDEWEB)

    Namasivayam, Saravanan [Department of Radiology, Division of Abdominal Imaging, Emory University School of Medicine, 1364 Clifton Road NE, Atlanta, GA 30322 (United States); Kalra, Mannudeep K. [Department of Radiology, Division of Abdominal Imaging, Emory University School of Medicine, 1364 Clifton Road NE, Atlanta, GA 30322 (United States); Waldrop, Sandra M. [Department of Radiology, Division of Abdominal Imaging, Emory University School of Medicine, 1364 Clifton Road NE, Atlanta, GA 30322 (United States); Mittal, Pardeep K. [Department of Radiology, Division of Abdominal Imaging, Emory University School of Medicine, 1364 Clifton Road NE, Atlanta, GA 30322 (United States); Small, William C. [Department of Radiology, Division of Abdominal Imaging, Emory University School of Medicine, 1364 Clifton Road NE, Atlanta, GA 30322 (United States)]. E-mail: wsmall@emory.edu

    2006-09-15

    Objective: To prospectively evaluate whether renal venous anatomy can be detected from arterial phase images of multidetector row CT (MDCT) of renal donors. Material and methods: Institutional review board approved our study protocol with waiver of consent. Forty-eight consecutive renal donors (age range, 21-56 years; M:F, 20:28) referred for MDCT evaluation were included. Two sub-specialty radiologists performed an independent and separate evaluation of renal venous anatomy in arterial and venous phase images. Opacification of renal venous structures was scored on a five-point scale (1-not seen; 3-minimal opacification; 5-excellent opacification). Arterial and venous phase opacification scores were compared by Wilcoxon signed rank test. Results: Both readers detected all renal venous anomalies in arterial as well as venous phase images. Each reader detected accessory right renal veins (n = 14), retroaortic left renal vein (n = 2), circumaortic left renal vein (n = 1), and left renal hilar arteriovenous malformation (n = 1) in arterial phase images. Retroaortic left renal venous branch was difficult to differentiate from lumbar vein (reader-1, n = 1; reader-2, n = 2) in both arterial and venous phase images. Sensitivity of detection of renal veins, left adrenal, gonadal and lumbar veins in arterial phase images was 100, 83-88, 100, and 85-90%, respectively. As expected, venous phase images showed significantly greater opacification of renal veins, left gonadal, adrenal and lumbar veins (p < .05). However, this did not substantially limit the evaluation of renal venous anatomy in arterial phase images. Both readers had substantial interobserver agreement (kappa coefficient, 0.7; p < 0.05). Conclusions: Arterial phase MDCT images alone can be used to detect renal venous anomalies, and to identify small left renal venous branches namely, the left gonadal, adrenal and lumbar veins in renal donors. Venous phase MDCT acquisition is not necessary for evaluation of renal

  17. Ankle-brachial index as indicator of chronic arterial insufficiency of the lower extremities and renal artery stenosis CT/DS angiography

    International Nuclear Information System (INIS)

    Georgiev, A.; Chervenkov, L.; Karadon, S.

    2015-01-01

    Full text: The aim is to validate the measurements of ankle -brachial index (ABI), as part of routine examination algorithm in conducting CTA/DSA of the extremities in patients suffering from PAD. Correlations between ABI values and renal artery stenosis. The present study includes 200 patients (138 men and 62 women, aged between 60 and 75 years). 130 of them were examined by a computer- tomography angiography - 95 men and 32 women. 70 patients were examined by digital subtraction angiography - 50 men and 20 women. Measurements of ankle-brachial index (ABI) were performed on all patients by measuring the systolic blood pressure on both brachial arteries and determine the peak pressure in both aa. dorsalis pedis. Statistical data processing. There are no patients in the study with ABI values above 0.7 that have established renal artery stenosis. All patients with severe atherosclerotic changes have values of the ABI below 0.7, and those with the most severe changes below 0.5. This fully corresponds to global data showing that values below 0.9 ABI show mild engagement, below 0.7 average, and below 0.5 severe involvement. According to the results of this survey sensitivity of ABI for renal arteries below 0.7 equals 100% and its specificity = 67.5%. For values of ABI below 0.5: Sensitivity =100%; Specificity = 83.85%. By determining ABI values both symptomatic and asymptomatic form of a PAD can be diagnosed. the method is fast, non-invasive, inexpensive and applicable everywhere. No special preparation of the patient is needed. The method can be used not only to assess the degree of commitment of the vessels of the lower limbs, but also as an indicator for the state of renal arteries in those patients

  18. Preventive effect of pretreatment with intravenous nicorandil on contrast-induced nephropathy in patients with renal dysfunction undergoing coronary angiography (PRINCIPLE Study).

    Science.gov (United States)

    Ko, Young-Guk; Lee, Byoung-Kwon; Kang, Woong Chol; Moon, Jae-Youn; Cho, Yun Hyeong; Choi, Seong Hun; Hong, Myeong-Ki; Jang, Yangsoo; Kim, Jong-Youn; Min, Pil-Ki; Kwon, Hyuck-Moon

    2013-07-01

    To investigate the effect of pretreatment with intravenous nicorandil on the incidence of contrast-induced nephropathy (CIN) in patients with renal dysfunction undergoing coronary angiography. This randomized controlled multicenter study enrolled a total of 166 patients (nicorandil n=81; control n=85) with an estimated glomerular filtration rate 0.5 mg/dL increase or >25% rise in serum creatinine (SCr) concentration within 48 hours of contrast exposure compared to baseline. The final analysis included 149 patients (nicorandil n=73; control n=76). The baseline characteristics and the total volume of the used contrast (Iodixanol, 125.6±69.1 mL vs. 126.9±74.6 mL, p=0.916) were similar between the two groups. The incidence of CIN also did not differ between the nicorandil and control groups (6.8% vs. 6.6%, p=0.794). There was no difference between the two groups in the relative change in SCr from baseline to peak level within 48 hours after coronary angiography (-1.58±24.07% vs. 0.96±17.49%, p=0.464), although the nicorandil group showed less absolute change in SCr than the control group (-0.01±0.43 mg/mL vs. 0.02±0.31 mg/mL, p=0.005). Prophylactic intravenous infusion of nicorandil did not decrease the incidence of CIN in patients with renal dysfunction undergoing coronary angiography.

  19. Evaluation of the renal venous system on late arterial and venous phase images with MDCT angiography in potential living laparoscopic renal donors

    International Nuclear Information System (INIS)

    Kawamoto, S.; Lawler, L.P.; Fishman, E.K.

    2005-01-01

    Objective: The objective of our study was to assess whether both renal arteries and renal veins can be evaluated using single-phase MDCT data sets alone to eliminate the need for both arterial and venous phase data sets. Materials and methods: One hundred consecutive potential living renal donors who underwent 4- MDCT were evaluated. CT was performed with 120 mL of IV contrast material at an injection rate of 3 mL/sec. Both late arterial and venous phase acquisitions were obtained at 25 and 55 sec from the start of IV contrast injection, respectively. The number of the right and left renal veins and its anatomic variations were assessed by two reviewers. Late arterial phase images were evaluated initially, and then venous phase images were analyzed to assess opacification of the renal vein and to see whether venous phase data sets changed or added information about the venous anatomy as seen on late arterial phase images. Results: The retroaortic left renal vein was found in two subjects, and the circumaortic left renal vein was detected in three subjects. The renal veins were adequately opacified on late arterial phase images in all subjects. There were six subjects who had a normal left renal vein with a small posterior branch coursing posterior to the aorta and draining into the inferior vena cava, which were difficult to differentiate from the lumbar vein or ascending lumbar vein; in three of these six subjects, the small posterior branch was opacified only on venous phase images. Conclusion: Late arterial phase images obtained at 25 sec after the start of contrast injection can reveal the renal vein anatomy except for a small posterior branch of the left renal vein difficult to differentiate from the lumbar or ascending lumbar vein, as seen in three subjects. The data suggest that venous phase imaging is not necessary for the evaluation of renal vein anatomy. (author)

  20. Evaluation of the renal venous system on late arterial and venous phase images with MDCT angiography in potential living laparoscopic renal donors

    Energy Technology Data Exchange (ETDEWEB)

    Kawamoto, S.; Lawler, L.P.; Fishman, E.K. [Johns Hopkins Hospital, Baltimore, MD (United States). The Russell H. Morgan Department of Radiology and Radiological Science

    2005-03-15

    Objective: The objective of our study was to assess whether both renal arteries and renal veins can be evaluated using single-phase MDCT data sets alone to eliminate the need for both arterial and venous phase data sets. Materials and methods: One hundred consecutive potential living renal donors who underwent 4- MDCT were evaluated. CT was performed with 120 mL of IV contrast material at an injection rate of 3 mL/sec. Both late arterial and venous phase acquisitions were obtained at 25 and 55 sec from the start of IV contrast injection, respectively. The number of the right and left renal veins and its anatomic variations were assessed by two reviewers. Late arterial phase images were evaluated initially, and then venous phase images were analyzed to assess opacification of the renal vein and to see whether venous phase data sets changed or added information about the venous anatomy as seen on late arterial phase images. Results: The retroaortic left renal vein was found in two subjects, and the circumaortic left renal vein was detected in three subjects. The renal veins were adequately opacified on late arterial phase images in all subjects. There were six subjects who had a normal left renal vein with a small posterior branch coursing posterior to the aorta and draining into the inferior vena cava, which were difficult to differentiate from the lumbar vein or ascending lumbar vein; in three of these six subjects, the small posterior branch was opacified only on venous phase images. Conclusion: Late arterial phase images obtained at 25 sec after the start of contrast injection can reveal the renal vein anatomy except for a small posterior branch of the left renal vein difficult to differentiate from the lumbar or ascending lumbar vein, as seen in three subjects. The data suggest that venous phase imaging is not necessary for the evaluation of renal vein anatomy. (author)

  1. Renal artery origins and variations: angiographic evaluation of 855 consecutive patients.

    Science.gov (United States)

    Ozkan, Uğur; Oğuzkurt, Levent; Tercan, Fahri; Kizilkiliç, Osman; Koç, Zafer; Koca, Nihal

    2006-12-01

    To determine angiographically the origins and variations of renal arteries. The study included 855 consecutive patients (163 females, 692 males; mean age, 61 years) living in the Cukurova region of Turkey, who underwent either aortofemoropopliteal (AFP) angiography for the investigation of peripheral arterial disease, or renal angiography for renovascular hypertension, and were prospectively evaluated. Renal arteries were visualized by non-selective catheterization during AFP angiography and by selective or non-selective catheterization during renal angiography. Locations of renal artery origins and renal artery variations, including the presence of extra renal arteries and division patterns were analyzed on angiograms. The origin of main renal arteries off the aorta was between the upper margin of L1 and lower margin of L2 vertebra in 98% of the patients, and in 74%, this was the origin of extra renal arteries. The most common location for renal artery origin was the L1-L2 intervertebral disc level. A single renal artery was present in both kidneys in 76% of patients. Renal artery variations included multiple arteries in 24%, bilateral multiple arteries in 5%, and early division in 8% of the cases. Additional renal arteries on the right side were found in 16% and on the left side in 13% of cases. Of all the extra renal arteries, the percentage of accessory and aberrant renal arteries were 49% and 51%, respectively. Renal arteries originated between the first and the second lumbar vertebral levels in most patients. Extra renal arteries were quite frequent. These results should be kept in mind when a non-invasive diagnostic search is performed for renal artery stenosis, or when renal surgery related to renal arteries is performed.

  2. Selective arterial embolization in the management of symptomatic renal angiomyolipomas

    Energy Technology Data Exchange (ETDEWEB)

    Mourikis, Dimitrios; Chatziioannou, Achilles; Antoniou, Aristidis; Kehagias, Dimitrios; Gikas, Dimitrios; Vlahos, Lambros

    1999-12-01

    Current management of renal angiomyolipomas (AMLs) include observation, transcatheter embolization and partial or total nephrectomy. Patients symptoms and size of the lesion are the determinants for the choice of the treatment. In general symptomatic or greater than 8 cm masses require intervention. A retrospective study of five patients presented with symptomatic lesions and treated with selective transcatheter embolization, over a 3 year period was performed in our hospital. A total of eight embolizations were performed, all on an emergency basis due to retroperitoneal bleeding or significant hematuria. Surgical intervention was necessary in one case, due to massive rebleeding on the fourth post-procedural day. Two patients rebled within 6 months and 2 years respectively, and were managed successfully with additional embolization. The remaining two patients are still asymptomatic 26 and 18 months after the successful initial result. Experience with this procedure is reported on with emphasis to the clinical outcome. It is believed that selective arterial embolization should be the standard initial therapy for symptomatic renal AMLs.

  3. Selective arterial embolization in the management of symptomatic renal angiomyolipomas

    International Nuclear Information System (INIS)

    Mourikis, Dimitrios; Chatziioannou, Achilles; Antoniou, Aristidis; Kehagias, Dimitrios; Gikas, Dimitrios; Vlahos, Lambros

    1999-01-01

    Current management of renal angiomyolipomas (AMLs) include observation, transcatheter embolization and partial or total nephrectomy. Patients symptoms and size of the lesion are the determinants for the choice of the treatment. In general symptomatic or greater than 8 cm masses require intervention. A retrospective study of five patients presented with symptomatic lesions and treated with selective transcatheter embolization, over a 3 year period was performed in our hospital. A total of eight embolizations were performed, all on an emergency basis due to retroperitoneal bleeding or significant hematuria. Surgical intervention was necessary in one case, due to massive rebleeding on the fourth post-procedural day. Two patients rebled within 6 months and 2 years respectively, and were managed successfully with additional embolization. The remaining two patients are still asymptomatic 26 and 18 months after the successful initial result. Experience with this procedure is reported on with emphasis to the clinical outcome. It is believed that selective arterial embolization should be the standard initial therapy for symptomatic renal AMLs

  4. Contrast-enhanced magnetic resonance angiography for the detection of crossing renal vessels in children with symptomatic ureteropelvic junction obstruction: comparison with operative findings.

    Science.gov (United States)

    Calder, Alistair D; Hiorns, Melanie P; Abhyankar, Aruna; Mushtaq, Imran; Olsen, Oystein E

    2007-04-01

    Crossing renal vessels (CRV) are associated with ureteropelvic junction (UPJ) obstruction, particularly when presentation is beyond the neonatal period. Their presence may influence surgical management. To evaluate the accuracy of contrast-enhanced magnetic resonance angiography (CE-MRA) in the identification of CRV in children requiring surgical treatment of symptomatic UPJ obstruction, against a gold standard of laparoscopic or open surgical findings. We reviewed CE-MRA studies (3-D T2-weighted turbo spin-echo and multiphase 3-D spoiled gradient echo following intravenous gadolinium administration) of 14 children, age range 6-15 years, performed prior to surgery for suspected CRV-related UPJ obstruction. Consensus reviews of the CE-MRA studies were compared with surgical findings. CE-MRA demonstrated CRV at the level of the obstruction in nine and no crossing vessels in five children. These were all verified intraoperatively (chi2=14.0; Pchildren older than 6 years with symptomatic UPJ obstruction.

  5. Catheter Angiography

    Medline Plus

    Full Text Available ... is performed using: x-rays with catheters computed tomography (CT) magnetic resonance imaging (MRI) In catheter angiography, ... tumor; this is called superselective angiography. Unlike computed tomography (CT) or magnetic resonance (MR) angiography , use of ...

  6. Catheter Angiography

    Medline Plus

    Full Text Available ... is performed using: x-rays with catheters computed tomography (CT) magnetic resonance imaging (MRI) In catheter angiography, a ... tumor; this is called superselective angiography. Unlike computed tomography (CT) or magnetic resonance (MR) angiography , use of a ...

  7. Catheter Angiography

    Medline Plus

    Full Text Available ... using: x-rays with catheters computed tomography (CT) magnetic resonance imaging (MRI) In catheter angiography, a thin plastic ... called superselective angiography. Unlike computed tomography (CT) or magnetic resonance (MR) angiography , use of a catheter makes it ...

  8. An automatic fuzzy-based multi-temporal brain digital subtraction angiography image fusion algorithm using curvelet transform and content selection strategy.

    Science.gov (United States)

    Momeni, Saba; Pourghassem, Hossein

    2014-08-01

    Recently image fusion has prominent role in medical image processing and is useful to diagnose and treat many diseases. Digital subtraction angiography is one of the most applicable imaging to diagnose brain vascular diseases and radiosurgery of brain. This paper proposes an automatic fuzzy-based multi-temporal fusion algorithm for 2-D digital subtraction angiography images. In this algorithm, for blood vessel map extraction, the valuable frames of brain angiography video are automatically determined to form the digital subtraction angiography images based on a novel definition of vessel dispersion generated by injected contrast material. Our proposed fusion scheme contains different fusion methods for high and low frequency contents based on the coefficient characteristic of wrapping second generation of curvelet transform and a novel content selection strategy. Our proposed content selection strategy is defined based on sample correlation of the curvelet transform coefficients. In our proposed fuzzy-based fusion scheme, the selection of curvelet coefficients are optimized by applying weighted averaging and maximum selection rules for the high frequency coefficients. For low frequency coefficients, the maximum selection rule based on local energy criterion is applied to better visual perception. Our proposed fusion algorithm is evaluated on a perfect brain angiography image dataset consisting of one hundred 2-D internal carotid rotational angiography videos. The obtained results demonstrate the effectiveness and efficiency of our proposed fusion algorithm in comparison with common and basic fusion algorithms.

  9. MR-angiography

    International Nuclear Information System (INIS)

    Seiderer, M.

    1989-01-01

    Three categories of MRI techniques for vascular imaging are discussed: 2d-angiography using rephasing and dephasing pulse sequences and slice selective imaging; 3d-angiography using rehpasing and dephasing pulse sequences and fas 3d-imaging techniques; 3d-angiography using signal intensity modulation caused by pre- and post-contrast data acquisition (e.g. Gadolinium-DTPA) in combination with fast 3d-imaging (only one type of pulse sequence). (H.W.). 6 figs

  10. Automated selection of the optimal cardiac phase for single-beat coronary CT angiography reconstruction

    International Nuclear Information System (INIS)

    Stassi, D.; Ma, H.; Schmidt, T. G.; Dutta, S.; Soderman, A.; Pazzani, D.; Gros, E.; Okerlund, D.

    2016-01-01

    Purpose: Reconstructing a low-motion cardiac phase is expected to improve coronary artery visualization in coronary computed tomography angiography (CCTA) exams. This study developed an automated algorithm for selecting the optimal cardiac phase for CCTA reconstruction. The algorithm uses prospectively gated, single-beat, multiphase data made possible by wide cone-beam imaging. The proposed algorithm differs from previous approaches because the optimal phase is identified based on vessel image quality (IQ) directly, compared to previous approaches that included motion estimation and interphase processing. Because there is no processing of interphase information, the algorithm can be applied to any sampling of image phases, making it suited for prospectively gated studies where only a subset of phases are available. Methods: An automated algorithm was developed to select the optimal phase based on quantitative IQ metrics. For each reconstructed slice at each reconstructed phase, an image quality metric was calculated based on measures of circularity and edge strength of through-plane vessels. The image quality metric was aggregated across slices, while a metric of vessel-location consistency was used to ignore slices that did not contain through-plane vessels. The algorithm performance was evaluated using two observer studies. Fourteen single-beat cardiac CT exams (Revolution CT, GE Healthcare, Chalfont St. Giles, UK) reconstructed at 2% intervals were evaluated for best systolic (1), diastolic (6), or systolic and diastolic phases (7) by three readers and the algorithm. Pairwise inter-reader and reader-algorithm agreement was evaluated using the mean absolute difference (MAD) and concordance correlation coefficient (CCC) between the reader and algorithm-selected phases. A reader-consensus best phase was determined and compared to the algorithm selected phase. In cases where the algorithm and consensus best phases differed by more than 2%, IQ was scored by three

  11. Renal blood flow after selective injection of different dosages of diatrizoate into the renal artery

    International Nuclear Information System (INIS)

    Burgener, F.A.; Fischer, H.W.; Weber, D.A.

    1975-01-01

    The characteristic biphasic renal haemodynamic response to diatrizoate injected into the renal artery was shown in the dog with the 133-xenon washout technique. A brief increase in renal blood flow (RBF) during the first ten seconds is followed by a more prolonged period of diminuished RBF. A dose of 4 ml. diatrizoate 60% resulted in the maximum RBF increase of 43% after ten seconds, but even 1 ml. diatrizoate raised the RBF 24%. The initial vasodilator effect of diatrizoate compares well in its extent with the most potent renal vasodilators. (orig.) [de

  12. Renal magnetic resonance angiography at 3.0 Tesla using a 32-element phased-array coil system and parallel imaging in 2 directions.

    Science.gov (United States)

    Fenchel, Michael; Nael, Kambiz; Deshpande, Vibhas S; Finn, J Paul; Kramer, Ulrich; Miller, Stephan; Ruehm, Stefan; Laub, Gerhard

    2006-09-01

    The aim of the present study was to assess the feasibility of renal magnetic resonance angiography at 3.0 T using a phased-array coil system with 32-coil elements. Specifically, high parallel imaging factors were used for an increased spatial resolution and anatomic coverage of the whole abdomen. Signal-to-noise values and the g-factor distribution of the 32 element coil were examined in phantom studies for the magnetic resonance angiography (MRA) sequence. Eleven volunteers (6 men, median age of 30.0 years) were examined on a 3.0-T MR scanner (Magnetom Trio, Siemens Medical Solutions, Malvern, PA) using a 32-element phased-array coil (prototype from In vivo Corp.). Contrast-enhanced 3D-MRA (TR 2.95 milliseconds, TE 1.12 milliseconds, flip angle 25-30 degrees , bandwidth 650 Hz/pixel) was acquired with integrated generalized autocalibrating partially parallel acquisition (GRAPPA), in both phase- and slice-encoding direction. Images were assessed by 2 independent observers with regard to image quality, noise and presence of artifacts. Signal-to-noise levels of 22.2 +/- 22.0 and 57.9 +/- 49.0 were measured with (GRAPPAx6) and without parallel-imaging, respectively. The mean g-factor of the 32-element coil for GRAPPA with an acceleration of 3 and 2 in the phase-encoding and slice-encoding direction, respectively, was 1.61. High image quality was found in 9 of 11 volunteers (2.6 +/- 0.8) with good overall interobserver agreement (k = 0.87). Relatively low image quality with higher noise levels were encountered in 2 volunteers. MRA at 3.0 T using a 32-element phased-array coil is feasible in healthy volunteers. High diagnostic image quality and extended anatomic coverage could be achieved with application of high parallel imaging factors.

  13. The clinical significances of selective ovarian arterial angiography and embolization in the obstetrics and gynecology

    International Nuclear Information System (INIS)

    Duan Feng; Liu Fengyong; Wang Maoqiang

    2007-01-01

    Transcatheter internal iliac arterial embolization has become a first-choice treatment for control of life-threatened bleeding associated with pelvic tumors or obstetric disorders. Recently, uterine arterial embolization (UAE)has offered a successful alternative to surgery in the treatment of uterine fibroid. Clinical failure rates for this procedure was reported from 4% to 19% in literature, probably due to the existence of collateral flow to the pelvic lesions, especially the ovarian arteries (OA)being the most important source. Furthermore, the anastomosis between the ovarian and uterine arteries has been suggested as the pathway for nontarget embolization of the ovaries causing premature menopause. The OA are simple paired vessels and they usually arise from the anterolateral part of the abdominal aorta at the level of the second lumbar vertebra. Variations in origin of OA occur in 2%-10% with diameter smaller than 1.1 mm and routinely not identified on conventional aortography. However, in the presence of a uterine or other pelvic diseases, the OA become dilated as the result of pathologic blood supply demand. OA supply to the pelvic lesions are more frequently found in patients with large fundal fibroids, history of the pelvic surgery, post embolization of the uterine arteries, and dysplasia of uterine artery. In patient with one or more of these predisposing factors, the extent of OA supply to the pelvic lesions should be assessed using pigtail catheter pelvic aortography with the tip at the level of the renal arteries, followed by selective OA catheterization. In case of identified OA supply to the pelvic lesions, superselective embolization of the OA should be considered, using particles with diameters larger than 500 μm. Proximal OA embolization, in combination with bilateral UAE, may significantly increase the risk of iatrogenic ovarian dysfunction. When necessary in a premenopausal patient, OA embolization should be performed unilaterally and as near

  14. Urinary Vitamin D Binding Protein and KIM-1 Are Potent New Biomarkers of Major Adverse Renal Events in Patients Undergoing Coronary Angiography.

    Directory of Open Access Journals (Sweden)

    Lyubov Chaykovska

    Full Text Available Vitamin-D-binding protein (VDBP is a low molecular weight protein that is filtered through the glomerulus as a 25-(OH vitamin D 3/VDBP complex. In the normal kidney VDBP is reabsorbed and catabolized by proximal tubule epithelial cells reducing the urinary excretion to trace amounts. Acute tubular injury is expected to result in urinary VDBP loss. The purpose of our study was to explore the potential role of urinary VDBP as a biomarker of an acute renal damage.We included 314 patients with diabetes mellitus or mild renal impairment undergoing coronary angiography and collected blood and urine before and 24 hours after the CM application. Patients were followed for 90 days for the composite endpoint major adverse renal events (MARE: need for dialysis, doubling of serum creatinine after 90 days, unplanned emergency rehospitalization or death.Increased urine VDBP concentration 24 hours after contrast media exposure was predictive for dialysis need (no dialysis: 113.06 ± 299.61 ng/ml, n = 303; need for dialysis: 613.07 ± 700.45 ng/ml, n = 11, Mean ± SD, p<0.001, death (no death during follow-up: 121.41 ± 324.45 ng/ml, n = 306; death during follow-up: 522.01 ± 521.86 ng/ml, n = 8; Mean ± SD, p<0.003 and MARE (no MARE: 112.08 ± 302.00 ng/ml, n = 298; MARE: 506.16 ± 624.61 ng/ml, n = 16, Mean ± SD, p<0.001 during the follow-up of 90 days after contrast media exposure. Correction of urine VDBP concentrations for creatinine excretion confirmed its predictive value and was consistent with increased levels of urinary Kidney Injury Molecule-1 (KIM-1 and baseline plasma creatinine in patients with above mentioned complications. The impact of urinary VDBP and KIM-1 on MARE was independent of known CIN risk factors such as anemia, preexisting renal failure, preexisting heart failure, and diabetes.Urinary VDBP is a promising novel biomarker of major contrast induced nephropathy-associated events 90 days after contrast media exposure.

  15. Gadofosveset-enhanced MR angiography of the pedal arteries in patients with diabetes mellitus and comparison with selective intraarterial DSA

    International Nuclear Information System (INIS)

    Roehrl, Boris; Kunz, Rainer Peter; Oberholzer, Katja; Pitton, Michael Bernhard; Dueber, Christoph; Kreitner, Karl-Friedrich; Neufang, Achim

    2009-01-01

    To compare gadofosveset-enhanced magnetic resonance angiography (MRA) of the pedal vasculature with selective intraarterial DSA. Eighteen patients with PAOD and type II diabetes were prospectively examined at 1.5 T. For contrast enhancement, 0.03 mmol/kg body weight gadofosveset was used. MR imaging consisted of dynamic and of high-resolution steady-state imaging. Selective digital subtraction angiography (DSA) was performed within 5 days and served as standard of reference. Image analysis was done by two observers. There were no differences between MRA and DSA regarding overall image quality. First-pass MRA detected significantly more patent vessel segments than did DSA (P < 0.001, kappa = 0.46). Interobserver agreement of MRA was very good with respect to the detection of patent vessel segments and the assessment of hemodynamically relevant stenoses (kappa = 0.97 and 0.89, respectively). Steady-state imaging depicted significantly more patent metatarsal arteries than did dynamic imaging, and delineated inflammatory complications including osteomyelitis, soft-tissue abscesses, and fistulas related to the diabetic foot. Gadofosveset-enhanced MRA of the pedal vasculature proved to be superior to DSA. It offered a long imaging time window, and allowed for better depiction of the pedal outflow. Steady-state imaging delineated inflammatory complications associated with the diabetic foot. (orig.)

  16. Gadofosveset-enhanced MR angiography of the pedal arteries in patients with diabetes mellitus and comparison with selective intraarterial DSA

    Energy Technology Data Exchange (ETDEWEB)

    Roehrl, Boris; Kunz, Rainer Peter; Oberholzer, Katja; Pitton, Michael Bernhard; Dueber, Christoph; Kreitner, Karl-Friedrich [Johannes Gutenberg University Mainz, Department of Diagnostic and Interventional Radiology, Mainz (Germany); Neufang, Achim [Johannes Gutenberg University Mainz, Department of Cardiothoracic and Vascular Surgery, Mainz (Germany)

    2009-12-15

    To compare gadofosveset-enhanced magnetic resonance angiography (MRA) of the pedal vasculature with selective intraarterial DSA. Eighteen patients with PAOD and type II diabetes were prospectively examined at 1.5 T. For contrast enhancement, 0.03 mmol/kg body weight gadofosveset was used. MR imaging consisted of dynamic and of high-resolution steady-state imaging. Selective digital subtraction angiography (DSA) was performed within 5 days and served as standard of reference. Image analysis was done by two observers. There were no differences between MRA and DSA regarding overall image quality. First-pass MRA detected significantly more patent vessel segments than did DSA (P < 0.001, kappa = 0.46). Interobserver agreement of MRA was very good with respect to the detection of patent vessel segments and the assessment of hemodynamically relevant stenoses (kappa = 0.97 and 0.89, respectively). Steady-state imaging depicted significantly more patent metatarsal arteries than did dynamic imaging, and delineated inflammatory complications including osteomyelitis, soft-tissue abscesses, and fistulas related to the diabetic foot. Gadofosveset-enhanced MRA of the pedal vasculature proved to be superior to DSA. It offered a long imaging time window, and allowed for better depiction of the pedal outflow. Steady-state imaging delineated inflammatory complications associated with the diabetic foot. (orig.)

  17. Prospective comparison of helical CT with angiography in pulmonary embolism: global and selective vascular territory analysis. Interobserver agreement

    International Nuclear Information System (INIS)

    Ruiz, Yolanda; Caballero, Paloma; Caniego, Jose Luis; Friera, Alfonsa; Olivera, Maria Jose; Tagarro, David; Alvarez-Sala, Rodolfo

    2003-01-01

    The objective of this prospective study was to evaluate the sensitivity, specificity, positive and negative predictive values, and interobserver agreement in the diagnosis of pulmonary embolism with helical CT, compared with pulmonary angiography, for both global results and for selective vascular territories. Helical CT and pulmonary angiography were performed on 66 consecutive patients with clinical suspicion of pulmonary embolism. The exams were blindly interpreted by a vascular radiologist and by two independent thoracic radiologists. Results were analyzed for the final diagnosis as well as separately for 20 different arterial territories in each patient. Pulmonary angiography revealed embolism in 25 patients (38%); 48% were main, 28% lobar, 16% segmental, and 8% subsegmental. The sensitivity, specificity, and positive and negative predictive values of helical CT for observer 1 were, respectively, 91, 81.5, 75, and 94%; in 7.5% of the patients the exam was considered indeterminate. For observer 2 the values were, respectively, 88, 86, 81.5, and 91%; in 9% of the patients the exam was considered indeterminate. Main arteries were considered as non-valuable in 0-0.8%, the lobar in 1.5%, the segmental in 7.5-8.5%, and the subsegmental in 55-60%. Interobserver agreement for the final diagnosis was 80% (kappa 0.65). For each vascular territory, this was 98% (kappa 0.91) for main arteries, 92% (kappa 0.78) for lobar arteries, 79% (kappa 0.56) for segmental arteries, and 59% (kappa 0.21) for subsegmental arteries. Helical CT is a reliable method for pulmonary embolism diagnosis, with good interobserver agreement for main, lobar, and segmental territories. Worse results are found for subsegmental arteries, with high incidence of non-valuable branches and poor interobserver agreement. (orig.)

  18. Contrast-enhanced magnetic resonance angiography for the detection of crossing renal vessels in children with symptomatic ureteropelvic junction obstruction: comparison with operative findings

    Energy Technology Data Exchange (ETDEWEB)

    Calder, Alistair D.; Hiorns, Melanie P.; Olsen, Oystein E. [Hospital for Children NHS Trust, Department of Radiology, London (United Kingdom); Abhyankar, Aruna; Mushtaq, Imran [Hospital for Children NHS Trust, Department of Urology, London (United Kingdom)

    2007-04-15

    Crossing renal vessels (CRV) are associated with ureteropelvic junction (UPJ) obstruction, particularly when presentation is beyond the neonatal period. Their presence may influence surgical management. To evaluate the accuracy of contrast-enhanced magnetic resonance angiography (CE-MRA) in the identification of CRV in children requiring surgical treatment of symptomatic UPJ obstruction, against a gold standard of laparoscopic or open surgical findings. We reviewed CE-MRA studies (3-D T2-weighted turbo spin-echo and multiphase 3-D spoiled gradient echo following intravenous gadolinium administration) of 14 children, age range 6-15 years, performed prior to surgery for suspected CRV-related UPJ obstruction. Consensus reviews of the CE-MRA studies were compared with surgical findings. CE-MRA demonstrated CRV at the level of the obstruction in nine and no crossing vessels in five children. These were all verified intraoperatively ({chi}{sup 2} = 14.0; P < 0.001). In eight of the nine patients with CRV there was no evidence of intrinsic obstruction at surgery. In the remaining patient there was fibrosis of the upper ureter. CE-MRA is an accurate means of identifying CRV in children older than 6 years with symptomatic UPJ obstruction. (orig.)

  19. Contrast-enhanced magnetic resonance angiography for the detection of crossing renal vessels in children with symptomatic ureteropelvic junction obstruction: comparison with operative findings

    International Nuclear Information System (INIS)

    Calder, Alistair D.; Hiorns, Melanie P.; Olsen, Oystein E.; Abhyankar, Aruna; Mushtaq, Imran

    2007-01-01

    Crossing renal vessels (CRV) are associated with ureteropelvic junction (UPJ) obstruction, particularly when presentation is beyond the neonatal period. Their presence may influence surgical management. To evaluate the accuracy of contrast-enhanced magnetic resonance angiography (CE-MRA) in the identification of CRV in children requiring surgical treatment of symptomatic UPJ obstruction, against a gold standard of laparoscopic or open surgical findings. We reviewed CE-MRA studies (3-D T2-weighted turbo spin-echo and multiphase 3-D spoiled gradient echo following intravenous gadolinium administration) of 14 children, age range 6-15 years, performed prior to surgery for suspected CRV-related UPJ obstruction. Consensus reviews of the CE-MRA studies were compared with surgical findings. CE-MRA demonstrated CRV at the level of the obstruction in nine and no crossing vessels in five children. These were all verified intraoperatively (χ 2 = 14.0; P < 0.001). In eight of the nine patients with CRV there was no evidence of intrinsic obstruction at surgery. In the remaining patient there was fibrosis of the upper ureter. CE-MRA is an accurate means of identifying CRV in children older than 6 years with symptomatic UPJ obstruction. (orig.)

  20. MRI angiography

    International Nuclear Information System (INIS)

    Poncelet, B.; Baleriiaux, D.; struyven, J.; Segebarth, C.

    1989-01-01

    In MRI angiography two basis images are measured which only differ by the signal intensity of the flowing blood in the vessels. Subtraction of these two images produces a high contrast-to-noise representation of the vessels. Contrast between stationary tissues and flowing blood is changed, for one image compared to the second one, using a selective modification of the phase of the signal from the flowing blood, and/or using a selective modification of its longitudinal magnetization: The macroscopic spin motions along the selection and the measurement gradient directions affect the phase of the nuclear signal; assuming constant velocity, the phase is proportional to the velocity and to the first moment of the gradient waveforms applied. This work concentrates on the generarion of MRI angiograms, following a phase-based approach, of the carotid bifurcation and of different intracranical regions including the carotid syphon and the circle of Willis. (author). 21 refs.; 3 figs

  1. Indications for coronary angiography

    International Nuclear Information System (INIS)

    Kaltenbach, M.; Vallbracht, C.

    1985-01-01

    Today selective coronary angiography, introduced by Sones in 1957, is used as clinical routine for diagnosing morphological changes in the coronary arteries. Hitherto, more recent techniques such as digital subtraction angiography cannot provide comparable information. Strict criteria for its indication depending on possible therapeutic consequences, have to be applied, although the risk is low with a letality of 0.01 to 0.05 percent. Radionuclear investigations can be used as additional tool in selected cases. The careful indication for coronary angiography usually implies the possible need for coronary bypass graft surgery of balloon angioplasty. (orig./MG) [de

  2. Catheter Angiography

    Medline Plus

    Full Text Available ... Angiography is a minimally invasive medical test that helps physicians diagnose and treat medical conditions. Angiography uses ... has narrowed the arteries to the legs and help prepare for endovascular intervention or surgery. detect disease ...

  3. Catheter Angiography

    Medline Plus

    Full Text Available ... you are pregnant and discuss any recent illnesses, medical conditions, medications you're taking and allergies, especially ... is Catheter Angiography? Angiography is a minimally invasive medical test that helps physicians diagnose and treat medical ...

  4. Catheter Angiography

    Medline Plus

    Full Text Available ... far outweighs the risk. If you have a history of allergy to x-ray contrast material, your ... Angiography (CTA) X-ray, Interventional Radiology and Nuclear Medicine Radiation Safety Images related to Catheter Angiography Sponsored ...

  5. Catheter Angiography

    Medline Plus

    Full Text Available ... story about radiology? Share your patient story here Images × Image Gallery Interventional radiologist performing an angiography exam View ... ray, Interventional Radiology and Nuclear Medicine Radiation Safety Images related to Catheter Angiography Sponsored by Please note ...

  6. Catheter Angiography

    Medline Plus

    Full Text Available ... resonance imaging (MRI) In catheter angiography, a thin plastic tube, called a catheter , is inserted into an ... The catheter used in angiography is a long plastic tube about as thick as a strand of ...

  7. Catheter Angiography

    Medline Plus

    Full Text Available ... lies. The catheter used in angiography is a long plastic tube about as thick as a strand of spaghetti. top of page How does the procedure work? Catheter angiography works much the same as a ...

  8. Does angiography increase the risk of impairment in renal function during non-operative management of patients with blunt splenic injuries? A cross-sectional study in southern Taiwan.

    Science.gov (United States)

    Hsieh, Ting-Min; Tsai, Tzu-Hsien; Lin, Chih-Che; Hsieh, Ching-Hua

    2016-10-21

    The aim of the present study was to assess whether angiography after contrast-enhanced CT (CECT) as per the policy of non-operative management would add to the risk of acute kidney injury in patients with blunt splenic injuries (BSIs). Cross-sectional study. Taiwan. Patients with BSI aged >16 years, admitted to a level I trauma centre during the period of January 2004 to December 2014, were retrospectively reviewed. A total of 326 patients with BSI with CECT were included in the study, of whom 100 underwent subsequent angiography and 226 did not. Incidence of contrast-induced nephropathy (CIN) and renal function as measured by the 48-hour serum creatinine (SCr) levels. No significant difference between the patients who underwent angiography and those who did not in terms of the initial haemoglobin (Hb), SCr or estimated glomerular filtration rate (eGFR) level on arrival at the emergency department, 48 hours later, or at discharge. No significant difference in the incidence of CIN was found between these two groups of patients regardless of the criteria for identifying CIN. In the group of patients aged ≥55 years, those who underwent angiography had a significantly worse 48-hour SCr level than those who did not undergo the treatment. In addition, there was no significant difference in the 48-hour SCr level between the two groups of patients when subgrouping the patients according to sex, large haemoperitoneum revealed on CT, systolic blood pressure, initial Hb, initial SCr and initial eGFR levels. This study demonstrated that angiography does not increase the incidence of CIN, and was not a risk factor to renal function impairment in patients with BSI who had undergone CECT. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/.

  9. Catheter Angiography

    Medline Plus

    Full Text Available ... Z Catheter Angiography Catheter angiography uses a catheter, x-ray imaging guidance and an injection of contrast material ... vessels in the body. Angiography is performed using: x-rays with catheters computed tomography (CT) magnetic resonance imaging ( ...

  10. Pediatric angiography

    International Nuclear Information System (INIS)

    Fitz, A.R.

    1987-01-01

    Angiography of the cerebral and visceral arterial systems is performed much less frequently than it was before the advent of computed tomographic scanning (CT). Most institutions have experienced at least a 50% reduction in the number of angiograms performed since installing a CT scanner. However, angiography still plays an important role in the confirmation of diagnoses made using a scanner, and in providing valuable information to the surgeon prior to excision of tumors or the repair of traumatized organs. Recently a number of sophisticated therapeutic procedures requiring vascular catheterization and the injection of contrast agents have been developed. In these procedures catheters are selectively placed in blood vessels perfusing a pathological process, such as an arteriovenous malformation, or at the site of an arterial stenosis; embolization of the arteriovenous malformation or tumor, or dilatation of the stenotic segment, is then performed. Whether the vessel catheterization is for diagnostic or therapeutic purposes, the basic approach is the same, and the technologist's duties are similar. The principal difference between a diagnostic and a therapeutic procedure is the length of time required to carry out the study; therapeutic procedures often require significantly longer periods of general anesthesia or sedation than do diagnostic studies

  11. Automatic selection of optimal systolic and diastolic reconstruction windows for dual-source CT coronary angiography

    International Nuclear Information System (INIS)

    Seifarth, H.; Puesken, M.; Wienbeck, S.; Maintz, D.; Heindel, W.; Juergens, K.U.; Fischbach, R.

    2009-01-01

    The aim of this study was to assess the performance of a motion-map algorithm that automatically determines optimal reconstruction windows for dual-source coronary CT angiography. In datasets from 50 consecutive patients, optimal systolic and diastolic reconstruction windows were determined using the motion-map algorithm. For manual determination of the optimal reconstruction window, datasets were reconstructed in 5% steps throughout the RR interval. Motion artifacts were rated for each major coronary vessel using a five-point scale. Mean motion scores using the motion-map algorithm were 2.4 ± 0.8 for systolic reconstructions and 1.9 ± 0.8 for diastolic reconstructions. Using the manual approach, overall motion scores were significantly better (1.9 ± 0.5 and 1.7 ± 0.6, p 90% of cases using either approach. Using the automated approach, there was a negative correlation between heart rate and motion scores for systolic reconstructions (ρ = -0.26, p 80 bpm (systolic reconstruction). (orig.)

  12. An experimental study on renal infarction with ethanol

    International Nuclear Information System (INIS)

    Han, Man Chung; Choi, Byung Ihn; Park, Jae Hyung; Ha, Sung Whan; Chang, Kee Hyun

    1982-01-01

    Renal infarction with ethanol was induced experimentally in rabbits and selective renal angiography was performed to evaluate the effectiveness of ethanol as embolic material. The results were as follows: 1. Complete obstruction of renal artery was produced in all cases within 1 week after injection of absolute ethanol (0.5 ml/Kg). 2. Incomplete obstruction of renal artery was produced in majority after injection of absolute ethanol (0.2 ml/Kg) and changed to complete obstruction above half cases with time. 3. Incomplete obstructive of renal artery was produced in minority after injection of 60% ethanol (0.2 ml/Kg) and complete obstruction of renal artery was not produced. It was consider that ethanol is an effective agent for complete renal infarction and 0.2 to 0.5 ml/Kg of absolute ethanol is effective dose for complete renal infarction

  13. Multislice CT angiography in the selection of patients with ruptured intracranial aneurysms suitable for clipping or coiling

    NARCIS (Netherlands)

    Westerlaan, H. E.; Gravendeel, J.; Fiore, D.; Metzemaekers, J. D. M.; Groen, R. J. M.; Mooij, J. J. A.; Oudkerk, M.

    2007-01-01

    Introduction We sought to establish whether CT angiography (CTA) can be applied to the planning and performance of clipping or coiling in ruptured intracranial aneurysms without recourse to intraarterial digital subtraction angiography (IA-DSA). Methods Over the period April 2003 to January 2006 in

  14. Catheter Angiography

    Medline Plus

    Full Text Available ... medical test that helps physicians diagnose and treat medical conditions. Angiography uses one of three imaging technologies and, in most cases, a contrast material injection ...

  15. Assessment of chronic thromboembolic pulmonary hypertension by three-dimensional contrast-enhanced MR angiography - comparison with selective intraarterial DSA

    International Nuclear Information System (INIS)

    Kreitner, K.F.; Ley, S.; Kauczor, H.U.; Kalden, P.; Pitton, M.B.; Thelen, M.; Mayer, E.; Laub, G.

    2000-01-01

    Purpose: This study compares contrast-enhanced 3D-MR angiography (MRA) of the pulmonary arteries with selective intraarterial DSA in patients with chronic thromboembolic pulmonary hypertension. Materials and methods: 20 patients preoperatively underwent a contrast-enhanced 3D-MRA of the pulmonary arteries at 1.5 T using the phased-array body coil. For MRA, we used a 3D-Flash-sequence after bolus timing. 2 radiologists analyzed the acquired image material in consensus with respect to the detection of central thromboembolic material and the visualization of the pulmonary arterial tree. Finally, the MR angiograms were compared with selective DSA images using surgical findings as the definitive standard. Results: MRA demonstrated central thromboembolic material, vessel cut-offs and abnormal proximal-to-distal tapering in all patients. Compared to DSA, MRA depicted the pulmonary vessels up to the segmental level in all cases, it was inferior to DSA in delineation of the subsegmental arteries (sensitivity 87%, specificity 100%). The central beginning of the thromboembolic occlusions seen at MRA corresponded to the beginning of the deobliteration procedure during pulmonary thromboendarterectomy in every case. (orig.) [de

  16. Automatic selection of optimal cardiac-phase in coronary CT angiography. Its clinical usefulness for patients with atrial fibrillation

    International Nuclear Information System (INIS)

    Matsumoto, Ryota; Narita, Hiroshi; Anno, Hirofumi; Ida, Yoshihiro; Sanda, Yoshihiro; Katada, Kazuhiro; Motoyama, Sadako; Sarai, Masayoshi; Tsuyuki, Masaharu

    2008-01-01

    The optimal cardiac phases for coronary CT angiography (CTA) are end-systole and mid-diastole, in which cardiac movement is slow. In conventional methods, these cardiac phases are determined by visual selection. We have compared the images in the optimal cardiac phases that were selected by the conventional method and cardiac-phase search software (Phase Navi), and examined the clinical usefulness of Phase Navi in patients with atrial fibrillation. The subjects were 38 patients (regular rhythm: 20, atrial fibrillation: 18). The continuity scores of patients with regular rhythm (Phase Navi, conventional methods) were 2.4±0.3-2.5±0.3 in end-systole and 2.4±0.5-2.4±0.4 in mid-diastole. The scores of patients with atrial fibrillation (Phase Navi, conventional methods) were 2.3±0.4-2.3±0.4 in end-systole, and 2.2±0.5-2.1±0.6 in mid-diastole. Because the continuity scores of the optimal images from Phase Navi were similar to those from the conventional method, Phase Navi had clinical usefulness in patients with atrial fibrillation. (author)

  17. Catheter Angiography

    Medline Plus

    Full Text Available Toggle navigation Test/Treatment Patient Type Screening/Wellness Disease/Condition Safety En Español More Info Images/Videos About Us News Physician Resources Professions Site Index A-Z Catheter Angiography Catheter angiography ...

  18. Catheter Angiography

    Medline Plus

    Full Text Available ... further information please consult the ACR Manual on Contrast Media and its references. The risk of serious allergic ... View full size with caption Related Articles and Media Angioplasty and Vascular Stenting MR Angiography (MRA) Contrast Materials CT Angiography (CTA) X-ray, Interventional Radiology ...

  19. Catheter Angiography

    Medline Plus

    Full Text Available Toggle navigation Test/Treatment Patient Type Screening/Wellness Disease/Condition Safety En Español More Info Images/Videos About Us News Physician ... Catheter Angiography? Angiography is a minimally invasive medical test that helps physicians diagnose and treat medical conditions. ...

  20. CT angiography for planning transcatheter aortic valve replacement using automated tube voltage selection: Image quality and radiation exposure

    Energy Technology Data Exchange (ETDEWEB)

    Mangold, Stefanie [Division of Cardiovascular Imaging, Department of Radiology and Radiological Science, Medical University of South Carolina, Charleston, SC (United States); Department of Diagnostic and Interventional Radiology, Eberhard-Karls University Tuebingen, Tuebingen (Germany); De Cecco, Carlo N. [Division of Cardiovascular Imaging, Department of Radiology and Radiological Science, Medical University of South Carolina, Charleston, SC (United States); Schoepf, U. Joseph, E-mail: schoepf@musc.edu [Division of Cardiovascular Imaging, Department of Radiology and Radiological Science, Medical University of South Carolina, Charleston, SC (United States); Division of Cardiology, Department of Medicine, Medical University of South Carolina, Charleston, SC (United States); Kuhlman, Taylor S.; Varga-Szemes, Akos [Division of Cardiovascular Imaging, Department of Radiology and Radiological Science, Medical University of South Carolina, Charleston, SC (United States); Caruso, Damiano [Division of Cardiovascular Imaging, Department of Radiology and Radiological Science, Medical University of South Carolina, Charleston, SC (United States); Department of Radiological Sciences, Oncology and Pathology, University of Rome “Sapienza”, Rome (Italy); Duguay, Taylor M. [Division of Cardiovascular Imaging, Department of Radiology and Radiological Science, Medical University of South Carolina, Charleston, SC (United States); Tesche, Christian [Department of Cardiology, Heart Centre Munich-Bogenhausen, Munich (Germany); Vogl, Thomas J. [Division of Cardiovascular Imaging, Department of Radiology and Radiological Science, Medical University of South Carolina, Charleston, SC (United States); Department of Diagnostic and Interventional Radiology, University Hospital Frankfurt, Frankfurt (Germany); Nikolaou, Konstantin [Department of Diagnostic and Interventional Radiology, Eberhard-Karls University Tuebingen, Tuebingen (Germany); and others

    2017-01-15

    Highlights: • TAVR-planning CT was performed with automated tube voltage selection. • Automated tube voltage selection enables individual tube voltage adaptation. • Image quality was diagnostic while radiation exposure was significantly decreased. - Abstract: Purpose: To assess image quality and accuracy of CT angiography (CTA) for transcatheter aortic valve replacement (TAVR) planning performed with 3rd generation dual-source CT (DSCT). Material and methods: We evaluated 125 patients who underwent TAVR-planning CTA on 3rd generation DSCT. A two-part protocol was performed including retrospectively ECG-gated coronary CTA (CCTA) and prospectively ECG-triggered aortoiliac CTA using 60 mL of contrast medium. Automated tube voltage selection and advanced iterative reconstruction were applied. Effective dose (ED), signal-to-noise (SNR) and contrast-to-noise ratios (CNR) were calculated. Five-point scales were used for subjective image quality analysis. In patients who underwent TAVR, sizing parameters were obtained. Results: Image quality was rated good to excellent in 97.6% of CCTA and 100% of aortoiliac CTAs. CTA studies at >100 kV showed decreased objective image quality compared to 70–100 kV (SNR, all p ≤ 0.0459; CNR, all p ≤ 0.0462). Mean ED increased continuously from 70 to >100 kV (CCTA: 4.5 ± 1.7 mSv–13.6 ± 2.9 mSv, all p ≤ 0.0233; aortoiliac CTA: 2.4 ± 0.9 mSv–6.8 ± 2.7 mSv, all p ≤ 0.0414). In 39 patients TAVR was performed and annulus diameter was within the recommended range in all patients. No severe cardiac or vascular complications were noted. Conclusion: 3rd generation DSCT provides diagnostic image quality in TAVR-planning CTA and facilitates reliable assessment of TAVR device and delivery option while reducing radiation dose.

  1. CT angiography for planning transcatheter aortic valve replacement using automated tube voltage selection: Image quality and radiation exposure

    International Nuclear Information System (INIS)

    Mangold, Stefanie; De Cecco, Carlo N.; Schoepf, U. Joseph; Kuhlman, Taylor S.; Varga-Szemes, Akos; Caruso, Damiano; Duguay, Taylor M.; Tesche, Christian; Vogl, Thomas J.; Nikolaou, Konstantin

    2017-01-01

    Highlights: • TAVR-planning CT was performed with automated tube voltage selection. • Automated tube voltage selection enables individual tube voltage adaptation. • Image quality was diagnostic while radiation exposure was significantly decreased. - Abstract: Purpose: To assess image quality and accuracy of CT angiography (CTA) for transcatheter aortic valve replacement (TAVR) planning performed with 3rd generation dual-source CT (DSCT). Material and methods: We evaluated 125 patients who underwent TAVR-planning CTA on 3rd generation DSCT. A two-part protocol was performed including retrospectively ECG-gated coronary CTA (CCTA) and prospectively ECG-triggered aortoiliac CTA using 60 mL of contrast medium. Automated tube voltage selection and advanced iterative reconstruction were applied. Effective dose (ED), signal-to-noise (SNR) and contrast-to-noise ratios (CNR) were calculated. Five-point scales were used for subjective image quality analysis. In patients who underwent TAVR, sizing parameters were obtained. Results: Image quality was rated good to excellent in 97.6% of CCTA and 100% of aortoiliac CTAs. CTA studies at >100 kV showed decreased objective image quality compared to 70–100 kV (SNR, all p ≤ 0.0459; CNR, all p ≤ 0.0462). Mean ED increased continuously from 70 to >100 kV (CCTA: 4.5 ± 1.7 mSv–13.6 ± 2.9 mSv, all p ≤ 0.0233; aortoiliac CTA: 2.4 ± 0.9 mSv–6.8 ± 2.7 mSv, all p ≤ 0.0414). In 39 patients TAVR was performed and annulus diameter was within the recommended range in all patients. No severe cardiac or vascular complications were noted. Conclusion: 3rd generation DSCT provides diagnostic image quality in TAVR-planning CTA and facilitates reliable assessment of TAVR device and delivery option while reducing radiation dose.

  2. Pediatric CT angiography

    International Nuclear Information System (INIS)

    Siegel, M.J.

    2005-01-01

    Advances in CT technology are having profound impact on imaging children and have made CT angiography possible even in neonates. Even with the tiny anatomy of neonates, small volumes of contrast material, and small venous access catheters, successful CT angiography can be performed with attention to detail. Meticulous attention to patient preparation, the proper selection of technical factors, and optimal delivery of contrast material are crucial. Data post-processing and the creation of 3-D reconstructions are also essential in establishing a correct diagnosis. The applications fo CT angiography are different in children than in adults and most applications in children involve assessment of congenital and postoperative vascular and cardiac diseases. The use of CT angiography offers the opportunity to eliminate the long periods of sedation associated with MR and reduce the radiation exposure associated with conventional angiography. Generally, the benefits of CT angiography in children outweigh the risk, namely that of radiation exposure. However, care must still be taken to minimize the radiation exposure. (orig.)

  3. Revisiting renovascular imaging for renal sympathetic denervation: current techniques and applications

    Energy Technology Data Exchange (ETDEWEB)

    Pua, Uei; Tan, Cher Heng [Tan Tock Seng Hospital, Department of Diagnostic Radiology, Singapore (Singapore); Ho, Hee Hwa; Tan, Julian Ko Beng; Ong, Paul Jau Leong [Tan Tock Seng Hospital, Department of Cardiology, Singapore (Singapore)

    2014-08-28

    Renal sympathetic denervation (RDN) is an emerging technique in the treatment of resistant hypertension, most commonly performed using an endovascular approach. Clinical and anatomical criteria for RDN are well established and imaging plays an integral role in selecting patients with suitable anatomy, procedural planning and device selection. Nevertheless, the current body of literature surrounding imaging related to RDN remains limited. The purpose of this article is to illustrate the expectations and limitations of various imaging techniques, including Doppler ultrasound, CT angiography, MR angiography and newer techniques such as non-contrast MR angiography, in the context of RDN. (orig.)

  4. Revisiting renovascular imaging for renal sympathetic denervation: current techniques and applications

    International Nuclear Information System (INIS)

    Pua, Uei; Tan, Cher Heng; Ho, Hee Hwa; Tan, Julian Ko Beng; Ong, Paul Jau Leong

    2015-01-01

    Renal sympathetic denervation (RDN) is an emerging technique in the treatment of resistant hypertension, most commonly performed using an endovascular approach. Clinical and anatomical criteria for RDN are well established and imaging plays an integral role in selecting patients with suitable anatomy, procedural planning and device selection. Nevertheless, the current body of literature surrounding imaging related to RDN remains limited. The purpose of this article is to illustrate the expectations and limitations of various imaging techniques, including Doppler ultrasound, CT angiography, MR angiography and newer techniques such as non-contrast MR angiography, in the context of RDN. (orig.)

  5. Vasovist-enhanced MR angiography

    International Nuclear Information System (INIS)

    Goyen, M.; Shamsi, K.; Schoenberg, S.O.

    2006-01-01

    Vasovist (MS-325) is the first intravascular contrast agent approved for use with magnetic resonance angiography in the European Union. Vasovist reversibly binds to albumin, providing extended intravascular enhancement compared to existing extracellular magnetic resonance contrast agents. Prior to approval, Vasovist underwent extensive testing to evaluate the safety and efficacy of the drug; the clinical trials program included blinded, placebo-controlled dose ranging, efficacy in a variety of vascular beds (AIOD, renal, pedal), examination of potential drug interaction with warfarin and comparison with XRA. The clinical trials show that Vasovist-enhanced MR angiography is safe and well-tolerated in patients with vascular disease, effective for the detection of vascular stenosis and aneurysms, significantly more accurate (both more sensitive and specific) than non-contrast MR angiography for the diagnosis of vascular stenoses, and similar to conventional angiography for the overall characterization of vascular disease, without the need for catheterization. (orig.)

  6. Vasovist-enhanced MR angiography

    Energy Technology Data Exchange (ETDEWEB)

    Goyen, M. [Univ. Medical Center, Hamburg-Eppendorf, Hamburg (Germany); Shamsi, K. [Berlex Lab., Inc., Montville, NJ (United States); Schoenberg, S.O. [Dept. of Clinical Radiology, Univ. Hospitals Grosshadern, Munich (Germany)

    2006-02-15

    Vasovist (MS-325) is the first intravascular contrast agent approved for use with magnetic resonance angiography in the European Union. Vasovist reversibly binds to albumin, providing extended intravascular enhancement compared to existing extracellular magnetic resonance contrast agents. Prior to approval, Vasovist underwent extensive testing to evaluate the safety and efficacy of the drug; the clinical trials program included blinded, placebo-controlled dose ranging, efficacy in a variety of vascular beds (AIOD, renal, pedal), examination of potential drug interaction with warfarin and comparison with XRA. The clinical trials show that Vasovist-enhanced MR angiography is safe and well-tolerated in patients with vascular disease, effective for the detection of vascular stenosis and aneurysms, significantly more accurate (both more sensitive and specific) than non-contrast MR angiography for the diagnosis of vascular stenoses, and similar to conventional angiography for the overall characterization of vascular disease, without the need for catheterization. (orig.)

  7. Comparison between angiography and CT scan in the urologic field

    Energy Technology Data Exchange (ETDEWEB)

    Fujioka, Toshio; Takao, Masaya; Odajima, Kunio; Nakamura, Hiroshi

    1988-02-01

    Seventy-five consecutive patients with urological diseases were examined preoperatively by means of computerized tomography and renal angiography. Classification of the diseases were 53 renal diseases which included renal cell carcinoma, sarcoma, cyst, renal bleeding, arteriovenous fistula, trauma, hydronephrosis and tuberculosis, 11 vesical diseases which included bladder tumor and endometriosis, 9 adrenal diseases which included primary aldosteronism, Cushing syndrome, pheochromocytoma, and metastatic tumor, and 1 case of intra-abdominal testes. For renal diseases, both angiography and CT were useful imaging tools. For vesical diseases, CT was a more useful imaging method but, for adrenal diseases, angiography was superior to CT. CT offers certain advantages over conventional techniques but, in the near future, it may be replaced by MRI. On the contrary, angiography will remain popular for a long time, because angiography is the only way to show which vessels feed organs.

  8. Intraoperative use of indocyanine green angiography for selecting the more reliable perforator of the anterolateral thigh flap: A comparison study.

    Science.gov (United States)

    La Padula, Simone; Hersant, Barbara; Meningaud, Jean Paul

    2018-03-30

    Anatomical variability of anterolateral thigh flap (ALT) perforators has been reported. The aim of this study is to assess if the use of intraoperative indocyanine green angiography (iICGA) can help surgeons to choose the ALT flap best perforator to be preserved. A retrospective study was conducted in 28 patients with open tibial fracture, following a road traffic crash, who had undergone ALT flap. Patients were classified into two groups: ICGA group (iICGA was used to select the more reliable perforator) and control group. The mean tissue loss size of the ICGA group (n = 13, 11 men and 2 women, mean age: 52 ± 6 years) was of 16.6 cm × 12.2 cm. The mean defect size of the control group (n = 15, 14 men and 1 women, mean age: 50 ± 5.52 years) was of 15.3 cm × 11.1 cm. Statistical analysis was performed to analyze and compare the results. ICGA allowed preserving only the most functional perforator, that provided the best ALT flap perfusion in 10 out of the 13 cases (77%). ICGA allowed a significant operative time reduction (160 ± 23 vs. 202 ± 48 minutes; P < .001). One case of distal necrosis was observed in the ICGA group (mean follow-up 12.3 months), while partial skin necrosis occurred in three cases of the control group (mean follow-up 13.1 months); P = .35. No additional coverage was required and a successful bone healing was observed in both groups. These findings suggest that iICGA is an effective method that allows to select the most reliable ALT flap perforators and to reduce operative time. © 2018 Wiley Periodicals, Inc.

  9. Catheter Angiography

    Medline Plus

    Full Text Available ... to your primary care or referring physician , who will discuss the results with you. top of page What are the benefits vs. risks? Benefits Angiography may eliminate the need ...

  10. Catheter Angiography

    Medline Plus

    Full Text Available ... you! Do you have a personal story about radiology? Share your patient story here Images × Image Gallery ... Contrast Materials CT Angiography (CTA) X-ray, Interventional Radiology and Nuclear Medicine Radiation Safety Images related to ...

  11. Catheter Angiography

    Medline Plus

    Full Text Available ... diagnosis and treatment in a single procedure. An example is finding an area of severe arterial narrowing, ... contrast material, your radiologist may advise that you take special medication for 24 hours before catheter angiography ...

  12. Catheter Angiography

    Medline Plus

    Full Text Available ... possible to combine diagnosis and treatment in a single procedure. Catheter angiography produces very detailed, clear and ... possible to combine diagnosis and treatment in a single procedure. An example is finding an area of ...

  13. Catheter Angiography

    Medline Plus

    Full Text Available ... medical conditions. Angiography uses one of three imaging technologies and, in most cases, a contrast material injection ... a tendency to bleed. top of page Additional Information and Resources Society of Interventional Radiology (SIR) - Patient ...

  14. Catheter Angiography

    Medline Plus

    Full Text Available ... medical conditions. Angiography uses one of three imaging technologies and, in most cases, a contrast material injection ... at these links. About Us | Contact Us | FAQ | Privacy | Terms of Use | Links | Site Map Copyright © 2018 ...

  15. Catheter Angiography

    Medline Plus

    Full Text Available ... imaging (MRI) In catheter angiography, a thin plastic tube, called a catheter , is inserted into an artery ... examined, a contrast material is injected through the tube and images are captured using a small dose ...

  16. Catheter Angiography

    Medline Plus

    Full Text Available ... spaghetti. top of page How does the procedure work? Catheter angiography works much the same as a ... angiogram may be performed in less than an hour; however, it may last several hours. top of ...

  17. Catheter Angiography

    Medline Plus

    Full Text Available ... accurate pictures of the blood vessels and may eliminate the need for surgery. Tell your doctor if ... are the benefits vs. risks? Benefits Angiography may eliminate the need for surgery. If surgery remains necessary, ...

  18. Catheter Angiography

    Medline Plus

    Full Text Available ... medical conditions. Angiography uses one of three imaging technologies and, in most cases, a contrast material injection ... possible charges you will incur. Web page review process: This Web page is reviewed regularly by a ...

  19. Catheter Angiography

    Medline Plus

    Full Text Available ... medical conditions. Angiography uses one of three imaging technologies and, in most cases, a contrast material injection ... congenital abnormalities in blood vessels, especially arteries in children (e.g., malformations in the heart or other ...

  20. Catheter Angiography

    Medline Plus

    Full Text Available ... medical conditions. Angiography uses one of three imaging technologies and, in most cases, a contrast material injection ... far outweighs the risk. If you have a history of allergy to x-ray contrast material, your ...

  1. Catheter Angiography

    Medline Plus

    Full Text Available ... spaghetti. top of page How does the procedure work? Catheter angiography works much the same as a ... and x-rays. Manufacturers of intravenous contrast indicate mothers should not breastfeed their babies for 24-48 ...

  2. Catheter Angiography

    Medline Plus

    Full Text Available ... of a catheter makes it possible to combine diagnosis and treatment in a single procedure. Catheter angiography ... of a catheter makes it possible to combine diagnosis and treatment in a single procedure. An example ...

  3. Catheter Angiography

    Medline Plus

    Full Text Available ... blood flow to the brain and cause a stroke. identify a small aneurysm or arteriovenous malformation (abnormal ... you. top of page What are the benefits vs. risks? Benefits Angiography may eliminate the need for ...

  4. Catheter Angiography

    Medline Plus

    Full Text Available ... iodine. If angiography is essential, a variety of methods is used to decrease risk of allergy: You ... radiation oncology provider in your community, you can search the ACR-accredited facilities database . This website does ...

  5. Catheter Angiography

    Medline Plus

    Full Text Available ... few millimeters) in the skin where the catheter can be inserted into an artery. The catheter is ... need for surgery. If surgery remains necessary, it can be performed more accurately. Catheter angiography presents a ...

  6. Catheter Angiography

    Medline Plus

    Full Text Available ... examine blood vessels in key areas of the body for abnormalities such as aneurysms and disease such ... to produce pictures of blood vessels in the body. Angiography is performed using: x-rays with catheters ...

  7. Catheter Angiography

    Medline Plus

    Full Text Available ... 20 minutes (or by using a special closure device). When the examination is complete, you may be ... contrast material, your radiologist may advise that you take special medication for 24 hours before catheter angiography ...

  8. Catheter Angiography

    Medline Plus

    Full Text Available ... Catheter angiography uses a catheter, x-ray imaging guidance and an injection of contrast material to examine ... removable dental appliances, eye glasses and any metal objects or clothing that might interfere with the x- ...

  9. Catheter Angiography

    Medline Plus

    Full Text Available ... rays ). top of page What are some common uses of the procedure? Catheter angiography is used to ... community, you can search the ACR-accredited facilities database . This website does not provide cost information. The ...

  10. Catheter Angiography

    Medline Plus

    Full Text Available ... spaghetti. top of page How does the procedure work? Catheter angiography works much the same as a ... possible to combine diagnosis and treatment in a single procedure. An example is finding an area of ...

  11. Catheter Angiography

    Medline Plus

    Full Text Available ... medical conditions. Angiography uses one of three imaging technologies and, in most cases, a contrast material injection ... American College of Radiology (ACR) and the European Society of Urogenital Radiology note that the available data ...

  12. Catheter Angiography

    Medline Plus

    Full Text Available ... with you. top of page What are the benefits vs. risks? Benefits Angiography may eliminate the need for surgery. If ... cancer from excessive exposure to radiation. However, the benefit of an accurate diagnosis far outweighs the risk. ...

  13. Catheter Angiography

    Medline Plus

    Full Text Available ... top of page What are the benefits vs. risks? Benefits Angiography may eliminate the need for surgery. ... in the typical diagnostic range for this exam. Risks There is always a slight chance of cancer ...

  14. Catheter Angiography

    Medline Plus

    Full Text Available ... most cases, the kidneys will regain their normal function within five to seven days. Rarely, the catheter ... limitations of Catheter Angiography? Patients with impaired kidney function, especially those who also have diabetes, are not ...

  15. Catheter Angiography

    Medline Plus

    Full Text Available ... medical conditions. Angiography uses one of three imaging technologies and, in most cases, a contrast material injection ... in key areas of the body, including the: brain neck heart chest abdomen (such as the kidneys ...

  16. Catheter Angiography

    Medline Plus

    Full Text Available ... medical conditions. Angiography uses one of three imaging technologies and, in most cases, a contrast material injection ... The video is produced by the x-ray machine and a detector that is suspended over a ...

  17. Catheter Angiography

    Medline Plus

    Full Text Available Toggle navigation Test/Treatment Patient Type Screening/Wellness Disease/Condition Safety En Español More Info Images/Videos About Us News Physician Resources Professions Site Index A-Z Catheter Angiography ...

  18. Catheter Angiography

    Medline Plus

    Full Text Available ... serious allergic reaction to contrast materials that contain iodine is extremely rare, and radiology departments are well- ... having a reaction to contrast materials that contain iodine. If angiography is essential, a variety of methods ...

  19. Severe hypertension due to renal polar artery stenosis in an adolescent treated with coil embolization

    Energy Technology Data Exchange (ETDEWEB)

    Docx, Martine K. [Koningin Paola Kinderziekenhuis, Department of Paediatrics, Chronic Diseases and Hypertension, Antwerp (Belgium); Vandenberghe, Philippe [Koningin Paola Kinderziekenhuis, Department of Paediatric Cardiology, Antwerp (Belgium); Maleux, Geert [University Hospitals Leuven, Department of Radiology, Leuven (Belgium); Gewillig, Marc [University Hospitals Leuven, Department of Paediatric Cardiology, Leuven (Belgium); Mertens, Luc [Hospital for Sick Children, Paediatric Cardiology, Toronto (Canada)

    2009-11-15

    A 12-year-old boy presented with severe arterial hypertension due to a severe subsegmental renal artery stenosis. Treatment consisted of selective embolization of the stenosed polar artery, which resulted in near normalization of the arterial pressures. Renal artery stenosis should always be considered, even in young adolescents, as a cause for arterial hypertension. Only selective angiography was able to demonstrate the subsegmental artery stenosis in this patient. (orig.)

  20. Severe hypertension due to renal polar artery stenosis in an adolescent treated with coil embolization

    International Nuclear Information System (INIS)

    Docx, Martine K.; Vandenberghe, Philippe; Maleux, Geert; Gewillig, Marc; Mertens, Luc

    2009-01-01

    A 12-year-old boy presented with severe arterial hypertension due to a severe subsegmental renal artery stenosis. Treatment consisted of selective embolization of the stenosed polar artery, which resulted in near normalization of the arterial pressures. Renal artery stenosis should always be considered, even in young adolescents, as a cause for arterial hypertension. Only selective angiography was able to demonstrate the subsegmental artery stenosis in this patient. (orig.)

  1. Evaluation of the patency of an extracranial-intracranial bypass using magnetic resonance angiography with selective presaturation of bypass vessels

    Energy Technology Data Exchange (ETDEWEB)

    Mabuchi, Shoji; Nakayama, Naoki; Isu, Toyohiko; Harata, Tatsuo; Nanbu, Toshikazu [Kushiro Rousai Hospital, Hokkaido (Japan)

    1994-06-01

    Three-dimensional time-of-flight magnetic resonance (MR) angiography using radiofrequency presaturation pulses was used to evaluate the patency of extracranial-intracranial (EC/IC) bypass in 11 patients. Presaturation causes signal loss in the vascular territory supplied by the presaturated EC/IC bypass graft. In all patients with a patent EC/IC bypass graft confirmed on conventional angiography, disappearance of the signal of the middle cerebral artery receiving blood flow from the bypass graft was clearly observed on MR angiograms with presaturation, indicating patency of the EC/IC bypass graft. MR angiography with presaturation pulses is a noninvasive and repeatable method for evaluation of the function of an EC/IC bypass graft. (author).

  2. Management of post-biopsy renal allograft arteriovenous fistulas with selective arterial embolization: immediate and long-term outcomes

    International Nuclear Information System (INIS)

    Loffroy, R.; Guiu, B.; Lambert, A.; Mousson, C.; Tanter, Y.; Martin, L.; Cercueil, J.-P.; Krause, D.

    2008-01-01

    Aim: To evaluate the outcomes after transcatheter embolization of percutaneous biopsy-related arteriovenous fistulas in renal allografts. Materials and methods: All post-biopsy renal-transplant vascular injuries referred for embolization between June 1999 and October 2006 were reviewed retrospectively. There were six male and six female patients with a mean age of 49.8 years (range 25-67 years); nine patients were symptomatic, three asymptomatic. Colour Doppler ultrasound (CDUS) and angiography showed one intra-renal arteriovenous fistula in 10 patients and two in two patients, combined with a pseudoaneurysm in six patients. Superselective embolization using a single catheter or coaxial microcatheter was performed with 0.035'' coils or 0.018''microcoils, respectively, in all 12 cases. 24-h creatinine clearance values before (the day of biopsy) and after (7-14 days; 3 months) the procedure were compared using the Wilcoxon signed-rank test. Physical examination and CDUS were performed after 1, 6, and 12 months, and yearly thereafter. Mean follow-up was 33.6 months. Results: Complete definitive occlusion of the fistula was achieved consistently with a single procedure. No procedure-related complications occurred. Renal infarction was minor in all patients (0-10% in nine and 10-20% in three). Symptoms resolved completely. Creatinine clearance values obtained before and after embolization were not statistically different (p = 0.168;.889 respectively). No late recurrences were reported. Conclusion: Transcatheter embolization with coaxial or single-catheter techniques was effective and safe for treating post-biopsy arteriovenous fistulas in renal transplants. The loss of renal parenchyma was minimal and no mid-term deterioration of allograft function was noted. The long-term survival of the renal allograft seemed to be not affected by embolization

  3. Flow measurements of the kidney after selective administration of radioactive xenon

    International Nuclear Information System (INIS)

    Franken, A.H.

    1983-01-01

    This thesis describes the results of perfusion studies in the kidney through the renal artery in human subjects, after selective administration of the inert radioactive gas Xenon-133. The examinations have been carried out in conjunction with renal angiography. From October 1979 to May 1981, a total of 150 studies have been performed in 86 patients. (Auth.)

  4. Coronary artery analysis: Computer-assisted selection of best-quality segments in multiple-phase coronary CT angiography

    Energy Technology Data Exchange (ETDEWEB)

    Zhou, Chuan, E-mail: chuan@umich.edu; Chan, Heang-Ping; Hadjiyski, Lubomir M.; Chughtai, Aamer; Wei, Jun; Kazerooni, Ella A. [Department of Radiology, The University of Michigan, Ann Arbor, Michigan 48109-0904 (United States)

    2016-10-15

    Purpose: The authors are developing an automated method to identify the best-quality coronary arterial segment from multiple-phase coronary CT angiography (cCTA) acquisitions, which may be used by either interpreting physicians or computer-aided detection systems to optimally and efficiently utilize the diagnostic information available in multiple-phase cCTA for the detection of coronary artery disease. Methods: After initialization with a manually identified seed point, each coronary artery tree is automatically extracted from multiple cCTA phases using our multiscale coronary artery response enhancement and 3D rolling balloon region growing vessel segmentation and tracking method. The coronary artery trees from multiple phases are then aligned by a global registration using an affine transformation with quadratic terms and nonlinear simplex optimization, followed by a local registration using a cubic B-spline method with fast localized optimization. The corresponding coronary arteries among the available phases are identified using a recursive coronary segment matching method. Each of the identified vessel segments is transformed by the curved planar reformation (CPR) method. Four features are extracted from each corresponding segment as quality indicators in the original computed tomography volume and the straightened CPR volume, and each quality indicator is used as a voting classifier for the arterial segment. A weighted voting ensemble (WVE) classifier is designed to combine the votes of the four voting classifiers for each corresponding segment. The segment with the highest WVE vote is then selected as the best-quality segment. In this study, the training and test sets consisted of 6 and 20 cCTA cases, respectively, each with 6 phases, containing a total of 156 cCTA volumes and 312 coronary artery trees. An observer preference study was also conducted with one expert cardiothoracic radiologist and four nonradiologist readers to visually rank vessel segment

  5. Coronary artery analysis: Computer-assisted selection of best-quality segments in multiple-phase coronary CT angiography

    International Nuclear Information System (INIS)

    Zhou, Chuan; Chan, Heang-Ping; Hadjiyski, Lubomir M.; Chughtai, Aamer; Wei, Jun; Kazerooni, Ella A.

    2016-01-01

    Purpose: The authors are developing an automated method to identify the best-quality coronary arterial segment from multiple-phase coronary CT angiography (cCTA) acquisitions, which may be used by either interpreting physicians or computer-aided detection systems to optimally and efficiently utilize the diagnostic information available in multiple-phase cCTA for the detection of coronary artery disease. Methods: After initialization with a manually identified seed point, each coronary artery tree is automatically extracted from multiple cCTA phases using our multiscale coronary artery response enhancement and 3D rolling balloon region growing vessel segmentation and tracking method. The coronary artery trees from multiple phases are then aligned by a global registration using an affine transformation with quadratic terms and nonlinear simplex optimization, followed by a local registration using a cubic B-spline method with fast localized optimization. The corresponding coronary arteries among the available phases are identified using a recursive coronary segment matching method. Each of the identified vessel segments is transformed by the curved planar reformation (CPR) method. Four features are extracted from each corresponding segment as quality indicators in the original computed tomography volume and the straightened CPR volume, and each quality indicator is used as a voting classifier for the arterial segment. A weighted voting ensemble (WVE) classifier is designed to combine the votes of the four voting classifiers for each corresponding segment. The segment with the highest WVE vote is then selected as the best-quality segment. In this study, the training and test sets consisted of 6 and 20 cCTA cases, respectively, each with 6 phases, containing a total of 156 cCTA volumes and 312 coronary artery trees. An observer preference study was also conducted with one expert cardiothoracic radiologist and four nonradiologist readers to visually rank vessel segment

  6. Update in the classification and treatment of complex renal injuries.

    Science.gov (United States)

    Reis, Leonardo Oliveira; Kim, Fernando J; Moore, Ernest E; Hirano, Elcio Shiyoiti; Fraga, Gustavo Pereira; Nascimento, Barto; Rizoli, Sandro

    2013-01-01

    The "Evidence-Based Telemedicine - Trauma and Acute Care Surgery" (EBT-TACS) Journal Club performed a critical review of the literature and selected three up-to-date articles on the management of renal trauma defined as American Association for the Surgery of Trauma (AAST) injury grade III-V. The first paper was the proposal for the AAST grade 4renal injury substratification into grades 4a (Low Risk) and 4b (High Risk). The second paper was a revision of the current AAST renal injury grading system, expanding to include segmental vascular injuries and to establish a more rigorous definition of severe grade IV and V renal injuries.The last article analyses the diagnostic angiography and angioembolization in the acute management of renal trauma using a national data set in the USA. The EBT-TACS Journal Club elaborated conclusions and recommendations for the management of high-grade renal trauma.

  7. Preoperative examination of potential renal transplant donors: value of gadolinium-enhanced 3D-MR-angiography in comparison with DSA and urography

    International Nuclear Information System (INIS)

    Winterer, J.T.; Paul, G.; Einert, A.; Altehoefer, C.; Uhrmeister, P.; Laubenberger, J.

    2000-01-01

    Purpose: To assess a contrast-enhanced standardized MRA protocol for the presurgical evaluation of potential renal transplant donors. Methods: Twenty-three potential donors for renal transplantations were examined with gadolinium-enhanced, two-phase MR angiograms (1.5 T) and DSA/urography for the number of renal arteries, the presence of aberrant arterial and venous branches, renal artery stenoses and anatomy of the renal collecting system and ureters. The diagnostic value was assessed by evaluating different image processing modalities and interobserver variability. Results: Using maximum intensity projections (MIP) together with multiplanar reformatting (MPR), accessory arteries were detected with a sensitivity/specificity of 100%/98%. Depending on diagnostic experience, exclusive evaluation of MIP yielded a sensitivitiy/specificity of 67-100%/95-100%. Using MIP/MPR, venous depiction was good in 80%, with MIP solely in 30-40%. At least the proximal third of the ureter was visible in 67%. Conclusion: MPR/MIP evaluation of two-phase, contrast-enhanced MRA provides an excellent depiction of renal vessel anatomy for presurgical evaluation of renal transplant donors. Exclusive MIP assessment is less reliable and depends strongly on the examiner's experience. For sufficient visualization of the ureters, either additional measurements or low-dose diuretic injection have to be performed. (orig.) [de

  8. An analysis of 30 patients with renal trauma

    International Nuclear Information System (INIS)

    Sakamoto, Eiji; Kuriki, Osamu; Takashi, Munehisa

    1989-01-01

    Thirty patients with renal trauma were studied by computerized tomography (CT) and angiography. Causes of injuries were traffic accidents in 19 patients (63%), falls in 5 (17%), sports in 2 (7%), and others in 4 (13%). Twenty-nine patients (97%) had hematuria, which was unrelated to the severity of injury. The remaining 3 patients (10%) had shock caused by severe renal injury. Of the 30 patients, 18 (60%) had renal contusions, 7 (23%) had minior laceration, 4 (13%) had major laceration and one had vascular injury. One patient had penetrating trauma and the other 29 had blunt trauma. Two patients (7%) had pre-existing renal anomalies. Sixteen patients (53%) had associated injuries that had no relation to the severity of the renal injury. In detecting subcapsular and perirenal hematoma, CT was more sentitive than excretory pyelography. Findings of renal angiography provided additional anatomical information in both deciding immediate surgical treatment and selecting operative methods for salvage of the kidney. Two patients with major lacerations and one with vascular injury underwent nephrectomy. The remaining 27 patients were managed successfully with conservative therapy. No late complications were seen, except in one case of pseudocyst formation. The persistence of microhematuria after injury was related to the severity of renal injury: a mean of 4.1 days for renal contrusions, 13 days for minor lacerations and 42 days for major lacerations. In conclusion, CT was useful for discriminating the severity of renal injury. When CT suggests major lacerations and vascular injuries, renal angiography should be performed for deciding immediate surgical intervention. (Namekawa, K)

  9. Catheter Angiography

    Medline Plus

    Full Text Available ... rare, and radiology departments are well-equipped to deal with them. There is a small risk that ... standard x-ray contrast. Catheter angiography should be done very cautiously—if at all—in patients who ...

  10. Catheter Angiography

    Medline Plus

    Full Text Available ... small burst of radiation that passes through the body, recording an image on photographic film or a special detector. Different ... about radiology? Share your patient story here Images × ... Related Articles and Media Angioplasty and Vascular Stenting MR Angiography (MRA) Contrast ...

  11. Catheter Angiography

    Medline Plus

    Full Text Available ... navigation Test/Treatment Patient Type Screening/Wellness Disease/Condition Safety En Español More Info Images/Videos About Us ... the equipment look like? How does the procedure work? How is the ... and treat medical conditions. Angiography uses one of three imaging technologies and, ...

  12. The selection of the parameters of high pressure syringe in performing interventional angiography: a retrospective analysis of 692 cases

    International Nuclear Information System (INIS)

    Shi Dehai; Luo Laishu; Yang Zhihong; Liu Yong

    2011-01-01

    Objective: To explore the optimal parameters of high pressure injector in performing interventional angiography and therapy of different parts of body in order to improve the image quality. Methods: During the period from July 2009 to September 2010 interventional angiography or therapy of different parts of body with the help of high pressure injector was performed in 692 patients, including 538 males and 154 females with a mean age of (53.6±2.5) years. The clinical data were retrospectively analyzed. The angiographic regions included vessels (n=341), cerebral vessels (n=71), thoracic larger vessels (n=19) and the vessels of the arms and legs (n=203). The technical parameters and the image qualities were evaluated and analyzed. Results: Based on the contrast filling degree, the presence or absence of contrast reflux, the imaging resolution and the satisfactory degree in meeting the diagnostic requirements, the angiographic images were evaluated. The image quality was up to standard in 615 cases (88.7%). Unsatisfactory contrast filling with no contrast reflux was seen in 62 cases (9.0%), and poor vascular opacification with contrast reflux was found in 9 cases (1.3%). Vagueness of the images caused by the body movement during exposure was seen in 6 cases (0.8%). No accidental events occurred in all procedures. Conclusion: The use of appropriate catheter, equipment and reasonable injecting parameters, which can match the characteristics of the target lesions, is the key to provide physicians with reliable angiography images. (authors)

  13. CT coronary angiography vs. invasive coronary angiography in CHD

    Directory of Open Access Journals (Sweden)

    Anja Hagen

    2012-04-01

    Full Text Available Scientific background: Various diagnostic tests including conventional invasive coronary angiography and non-invasive computed tomography (CT coronary angiography are used in the diagnosis of coronary heart disease (CHD. Research questions: The present report aims to evaluate the clinical efficacy, diagnostic accuracy, prognostic value cost-effectiveness as well as the ethical, social and legal implications of CT coronary angiography versus invasive coronary angiography in the diagnosis of CHD. Methods: A systematic literature search was conducted in electronic data bases (MEDLINE, EMBASE etc. in October 2010 and was completed with a manual search. The literature search was restricted to articles published from 2006 in German or English. Two independent reviewers were involved in the selection of the relevant publications. The medical evaluation was based on systematic reviews of diagnostic studies with invasive coronary angiography as the reference standard and on diagnostic studies with intracoronary pressure measurement as the reference standard. Study results were combined in a meta-analysis with 95 % confidence intervals (CI. Additionally, data on radiation doses from current non-systematic reviews were taken into account. A health economic evaluation was performed by modelling from the social perspective with clinical assumptions derived from the meta-analysis and economic assumptions derived from contemporary German sources. Data on special indications (bypass or in-stent-restenosis were not included in the evaluation. Only data obtained using CT scanners with at least 64 slices were considered. Results: No studies were found regarding the clinical efficacy or prognostic value of CT coronary angiography versus conventional invasive coronary angiography in the diagnosis of CHD. Overall, 15 systematic reviews with data from 44 diagnostic studies using invasive coronary angiography as the reference standard (identification of obstructive

  14. Autotransplant tissue selection criteria with or without stereomicroscopy in parathyroidectomy for treatment of renal hyperparathyroidism

    Directory of Open Access Journals (Sweden)

    Monique Nakayama Ohe

    2014-07-01

    Full Text Available INTRODUCTION: Several methods have been proposed to improve operative success in renal hyperparathyroidism. OBJECTIVE: To evaluate stereomicroscopy in parathyroid tissue selection for total parathyroidectomy with autotransplantation in secondary (SHPT/tertiary (THPT hyperparathyroidism. METHODS: 118 renal patients underwent surgery from April of 2000 to October 2009. They were divided into two groups: G1, 66 patients operated from April of 2000 to May of 2005, with tissue selection based on macroscopic observation; G2, 52 patients operated from March of 2008 to October 2009 with stereomicroscopy for tissue selection searching for the presence of adipose cells. All surgeries were performed by the same surgeon. Patients presented SHPT (dialysis treatment or THPT (renal-grafted. Follow-up was 12-36 months. Intra-operative parathyroid hormone (PTH was measured in 100/118 (84.7% patients. RESULTS: Data are presented as means. G1 included 66 patients (38 SHPT, 24 females/14 males; 40.0 years of age; 28 THPT, 14 females/14 males; 44 years of age. G2 included 52 patients (29 SHPT, 11 females/18 males; 50.7 years of age; 23 THPT, 13 females/10 males, 44.4 years of age. SHPT patients from G2 presented preoperative serum calcium higher than those of SHPT patients in G1 (p < 0.05, suggesting a more severe disease. Definitive hypoparathyroidism was found in seven of 118 patients (5.9%. Graft-dependent recurrence occurred in four patients, two in each group. All occurred in dialysis patients. CONCLUSION: Stereomicroscopy in SHPT/THPT surgical treatment may be a useful tool to standardize parathyroid tissue selection.

  15. Renal angiographic and computed tomographic evaluation of local extension of renal cell carcinoma

    International Nuclear Information System (INIS)

    Masuda, Fujio; Onishi, Tetsuro; Sasaki, Tadamasa; Arai, Yoshikazu; Shoji, Ryo

    1981-01-01

    In 23 cases of renal cell carcinoma, the degree of local invasion of carcinoma was diagnosed using renal angiography and CT, and compared with the findings obtained by operation or autopsy. Among 5 cases in which the tumor was confined to the renal capsule, accurate diagnosis could be established with renal angiography in 4 cases and with CT in all of 5 cases. Both renal angiography and CT provided correct diagnosis in 7 of 8 cases in which the tumor showed infiltration extending to the perinephric fat. Out of 5 cases with tumor invasion of renal vein or inferior vena cava, diagnosis could be established correctly by renal angiography and CT in 3 cases. Among the remaining 2 cases the diagnosis could be established by renal angiography and CT in one each case. Among 5 cases with metastases to the regional lymph nodes, diagnosis could be established by renal angiography in only 2 cases, while all of 5 cases could be diagnosed by CT. In 3 cases where the tumor invaded an ajacent organ beyond Gerota's fastia, renal angiography could diagnose in none of the 3 cases while with CT all of 3 cases could successfully be diagnosed. The consistency of degree of local invasion as revealed by renal angiography and CT was seen in 15 of 23 cases (65%) for renal agniography and 20 of 23 cases (87%) for CT, indicating superiority of CT in this respect. In particular, CT appears to be more superior to renal angiography for determining whether the tumor confined to Gerota's fastia or it infiltrated over it. Both combined use of renal angiography and CT, the degree of infiltration of tumor could be diagnosed correctly in 22 of 23 cases (96%). (author)

  16. Renal artery stenosis.

    Science.gov (United States)

    Tafur-Soto, Jose David; White, Christopher J

    2015-02-01

    Atherosclerotic renal artery stenosis (RAS) is the single largest cause of secondary hypertension; it is associated with progressive renal insufficiency and causes cardiovascular complications such as refractory heart failure and flash pulmonary edema. Medical therapy, including risk factor modification, renin-angiotensin-aldosterone system antagonists, lipid-lowering agents, and antiplatelet therapy, is advised in all patients. Patients with uncontrolled renovascular hypertension despite optimal medical therapy, ischemic nephropathy, and cardiac destabilization syndromes who have severe RAS are likely to benefit from renal artery revascularization. Screening for RAS can be done with Doppler ultrasonography, CT angiography, and magnetic resonance angiography. Copyright © 2015 Elsevier Inc. All rights reserved.

  17. Catheter versus non-catheter angiography in isolated third nerve palsy

    International Nuclear Information System (INIS)

    Lee, A.G.

    2007-01-01

    To discuss the controversies surrounding the indications for catheter angiography versus non-catheter and less invasive angiography techniques (e.g. magnetic resonance angiography (MRA) and computerized tomography angiography (CTA)) in the evaluation of patients with a third nerve palsy. Clinical opinion-perspective and literature review. The patient with an isolated third nerve palsy might have a vasculopathic (and typically benign, self limited course) etiology or a life threatening intracranial posterior communicating artery aneurysm. Although it is clear that non-isolated third nerve palsies require imaging directed at the topographical localization of the clinical findings, the evaluation of the neurologically isolated third nerve palsy remains controversial. The completeness of the external (i.e. somatic) motor dysfunction and the presence or absence of internal (i.e. pupillary) dysfunction are generally used to guide the choice of initial neuroimaging. Advances in MRA and CTA technology have reduced but not eliminated our dependence upon catheter angiography in this setting. A properly performed and interpreted MRA or CTA probably will be able to detect greater than 95 % of aneurysms producing a third nerve palsy. The issues surrounding the use of catheter angiography in third nerve palsy are reviewed. If the clinician is highly confident in the capability, availability, and reliability of the neuroradiologist and of their institutional experience and quality of less invasive non-catheter MRA and CTA and if the risk of aneurysm is low or if the risk of angiography is high (e.g. elderly, renal failure, iodinated contrast allergy, risk of stroke) then MRI and MRA (or CTA) may be a reasonable alternative to catheter angiography. Patients with a moderate or uncertain risk of aneurysm and a lower risk for catheter angiography or if there is a low confidence in the quality or the interpretation of the institutional MRA (or CTA) may still require catheter

  18. Use of ECG-gated computed tomography, echocardiography and selective angiography in five dogs with pulmonic stenosis and one dog with pulmonic stenosis and aberrant coronary arteries.

    Science.gov (United States)

    Laborda-Vidal, P; Pedro, B; Baker, M; Gelzer, A R; Dukes-McEwan, J; Maddox, T W

    2016-12-01

    Pulmonic stenosis (PS) is the most common congenital cardiac disease in dogs. Boxers and English bulldogs are among the most commonly affected breeds and also commonly associated with an aberrant coronary artery (CA). If an aberrant CA is suspected and balloon valvuloplasty indicated, an intra-operative angiography is recommended prior to the procedure. ECG-gated computed tomography (CT) can be used to screen for CA anomalies in a quick and minimally-invasive way (preventing side effects associated with selective catheter angiography) and allowing early planning of the procedure. The aim of this case series was to report CT findings associated with PS diagnosed by echocardiography. Our database was retrospectively searched for cases of dogs with PS diagnosed by echocardiography, where an ECG-gated CT was performed. A total of six cases were retrieved: all were diagnosed with severe PS. Four dogs had concurrent congenital defects: two dogs had a patent ductus arteriosus, one dog had a ventricular septal defect and an overriding aorta, one dog had an aberrant CA. Detailed CT findings of all cases were reported, including one case of a patent ductus arteriosus and an overriding aorta not identified by transthoracic echocardiography. In addition, an abnormal single left coronary ostium, with a pre-pulmonic right CA was described. In conclusion, despite echocardiography remaining the gold standard for diagnosis and assessment of PS, ECG-gated-CT angiography is a complementary diagnostic method that may provide additional relevant information, shorten surgery/anaesthesia time and reduce the amount of radiation to which the clinician is subjected. Copyright © 2016 Elsevier B.V. All rights reserved.

  19. Renal zoomed EPI-DWI with spatially-selective radiofrequency excitation pulses in two dimensions

    Energy Technology Data Exchange (ETDEWEB)

    He, Yong-Lan, E-mail: ylhe_526@163.com [Department of Radiology, Peking Union Medical College Hospital, Peking Union Medical College and Chinese Academy of Medical Sciences, Beijing (China); Hausmann, Daniel, E-mail: daniel.hausmann@medma.uni-heidelberg.de [Institute of Clinical Radiology and Nuclear Medicine, University Medical Center Mannheim, Medical Faculty Mannheim – Heidelberg University, Mannheim (Germany); Morelli, John N., E-mail: dr.john.morelli@gmail.com [St. John' s Medical Center, Tulsa, OK (United States); Attenberger, Ulrike I., E-mail: ulrike.attenberger@medma.uni-heidelberg.de [Institute of Clinical Radiology and Nuclear Medicine, University Medical Center Mannheim, Medical Faculty Mannheim – Heidelberg University, Mannheim (Germany); Schoenberg, Stefan O., E-mail: stefan.schoenberg@umm.de [Institute of Clinical Radiology and Nuclear Medicine, University Medical Center Mannheim, Medical Faculty Mannheim – Heidelberg University, Mannheim (Germany); Riffel, Philipp, E-mail: philipp.riffel@umm.de [Institute of Clinical Radiology and Nuclear Medicine, University Medical Center Mannheim, Medical Faculty Mannheim – Heidelberg University, Mannheim (Germany)

    2016-10-15

    Highlights: • Renal zoomed diffusion-weighted imaging with spatially-selective radiofrequency excitation pulses is feasible. • z-EPI offers considerable potential for mitigating the limitations of conventional EPI techniques. • z-EPI of kidney may lead to substantial image quality improvements with reduced artifacts. - Abstract: Purpose: To evaluate the feasibility and clinical robustness of zoomed diffusion-weighted echo planar imaging (z-EPI) relative to conventional single-shot EPI (c-EPI) for DWI of the kidneys. Materials and methods: This retrospective study was approved by the institutional research ethics board. 66 patients (median age 58.5 years ± 13.4, range 23–83 years, 45 men, 21 women) undergoing 3T (Magnetom Skyra{sup ®}, Siemens Healthcare, Erlangen, Germany) using a dynamic parallel transmit array (TimTX TrueShape, Siemens Healthcare, Erlangen, Germany) for renal MRI were included in this study. Both c-EPI and z-EPI images were obtained. For z-EPI, a two-dimensional spatially-selective radiofrequency (RF) pulse was applied for echo planar imaging with the FOV reduced by a factor of 3. Two radiologists, blinded to clinical data and scan parameters evaluated the images with respect to their diagnostic confidence, overall preference, overall image quality, delineation of the kidney, spatial distortion, and image blur. Sequences were compared using a paired Wilcoxon test. ADC values for the upper pole, mid-zone, lower pole of the normal kidneys were compared between sequences as well as ADC values for renal lesions, using a paired t-test. Results: With z-EPI, the kidney was significantly better delineated with sharper boundaries, less image blur and distortion, and overall better image quality relative to c-EPI (all p < 0.001). The z-EPI technique led to greater diagnostic confidence than c-EPI (p = 0.020). z-EPI was preferred to c-EPI in 60 cases (90.9%, 60/66). No statistically significant differences in the ADC values of renal parenchyma or

  20. Renal zoomed EPI-DWI with spatially-selective radiofrequency excitation pulses in two dimensions

    International Nuclear Information System (INIS)

    He, Yong-Lan; Hausmann, Daniel; Morelli, John N.; Attenberger, Ulrike I.; Schoenberg, Stefan O.; Riffel, Philipp

    2016-01-01

    Highlights: • Renal zoomed diffusion-weighted imaging with spatially-selective radiofrequency excitation pulses is feasible. • z-EPI offers considerable potential for mitigating the limitations of conventional EPI techniques. • z-EPI of kidney may lead to substantial image quality improvements with reduced artifacts. - Abstract: Purpose: To evaluate the feasibility and clinical robustness of zoomed diffusion-weighted echo planar imaging (z-EPI) relative to conventional single-shot EPI (c-EPI) for DWI of the kidneys. Materials and methods: This retrospective study was approved by the institutional research ethics board. 66 patients (median age 58.5 years ± 13.4, range 23–83 years, 45 men, 21 women) undergoing 3T (Magnetom Skyra ® , Siemens Healthcare, Erlangen, Germany) using a dynamic parallel transmit array (TimTX TrueShape, Siemens Healthcare, Erlangen, Germany) for renal MRI were included in this study. Both c-EPI and z-EPI images were obtained. For z-EPI, a two-dimensional spatially-selective radiofrequency (RF) pulse was applied for echo planar imaging with the FOV reduced by a factor of 3. Two radiologists, blinded to clinical data and scan parameters evaluated the images with respect to their diagnostic confidence, overall preference, overall image quality, delineation of the kidney, spatial distortion, and image blur. Sequences were compared using a paired Wilcoxon test. ADC values for the upper pole, mid-zone, lower pole of the normal kidneys were compared between sequences as well as ADC values for renal lesions, using a paired t-test. Results: With z-EPI, the kidney was significantly better delineated with sharper boundaries, less image blur and distortion, and overall better image quality relative to c-EPI (all p < 0.001). The z-EPI technique led to greater diagnostic confidence than c-EPI (p = 0.020). z-EPI was preferred to c-EPI in 60 cases (90.9%, 60/66). No statistically significant differences in the ADC values of renal parenchyma or of

  1. Gallbladder visualization on CT shortly after angiography with ioxaglate

    International Nuclear Information System (INIS)

    Tajima, H.; Kaizu, T.; Ichikawa, T.; Kumazaki, T.

    1994-01-01

    Thirty-five patients underwent CT examination 15 to 30 min after abdominal angiography with ioxaglate. The gallbladder was visualized in 12 patients in the absence of clinical evidence of renal impairment. Gallbladder opacification on CT examinations shortly after angiography shows that the hepatobiliary tract is important in the excretion of ioxaglate. (orig.)

  2. Renal Arteriovenous Shunts: Clinical Features, Imaging Appearance, and Transcatheter Embolization Based on Angioarchitecture.

    Science.gov (United States)

    Maruno, Miyuki; Kiyosue, Hiro; Tanoue, Shuichi; Hongo, Norio; Matsumoto, Shunro; Mori, Hiromu; Sagara, Yoshiko; Kashiwagi, Junji

    2016-01-01

    Renal arteriovenous (AV) shunt, a rare pathologic condition, is divided into two categories, traumatic and nontraumatic, and can cause massive hematuria, retroperitoneal hemorrhage, pain, and high-output heart failure. Although transcatheter embolization is a less-invasive and effective treatment option, it has a potential risk of complications, including renal infarction and pulmonary embolism, and a potential risk of recanalization. The successful embolization of renal AV shunt requires a complete occlusion of the shunted vessel while preventing the migration of embolic materials and preserving normal renal arterial branches, which depends on the selection of adequate techniques and embolic materials for individual cases, based on the etiology and imaging angioarchitecture of the renal AV shunts. A classification of AV malformations in the extremities and body trunk could precisely correspond with the angioarchitecture of the nontraumatic renal AV shunts. The selection of techniques and choice of adequate embolic materials such as coils, vascular plugs, and liquid materials are determined on the basis of cause (eg, traumatic vs nontraumatic), the classification, and some other aspects of the angioarchitecture of renal AV shunts, including the flow and size of the fistulas, multiplicity of the feeders, and endovascular accessibility to the target lesions. Computed tomographic angiography and selective digital subtraction angiography can provide precise information about the angioarchitecture of renal AV shunts before treatment. Color Doppler ultrasonography and time-resolved three-dimensional contrast-enhanced magnetic resonance angiography represent useful tools for screening and follow-up examinations of renal AV shunts after embolization. In this article, the classifications, imaging features, and an endovascular treatment strategy based on the angioarchitecture of renal AV shunts are described. (©)RSNA, 2016.

  3. Digital image evaluation for the determination of morphometric sizes for periodontal X-ray diagnosis and selective coronary angiography

    International Nuclear Information System (INIS)

    Barth, K.

    1982-01-01

    In its uses in the areas of periodontology and coronary angiography it is shown, how the digital image evaluation expands the possibilities of x-ray diagnosis and how it improves the objectivity and exactness of the evaluation. For the accomplishment of this task a detailed analysis of the morphological data is undertaken. The results of the analysis lead to a mathematical structure model. Based on this model the recognition and measuring of the object in an adaptive heuristic process is undertaken. In this case it dealt with a desmodontal split, whose change is indicated by a periodontal bone atrophy. The contour recognition is embedded in a newly created image processing system, which allows itself to be used generally and is shown using the presentation of coronary vessels as an example. The exactness of the automatic image evaluation in comparison to the measuring done by the doctor is discussed. (orig./TRV) [de

  4. Multiple Renal Artery Pseudoaneurysms in Patients Undergoing Renal Artery Embolization Following Partial Nephrectomy: Correlation with RENAL Nephrometry Scores

    International Nuclear Information System (INIS)

    Gupta, Nakul; Patel, Anish; Ensor, Joe; Ahrar, Kamran; Ahrar, Judy; Tam, Alda; Odisio, Bruno; Huang, Stephen; Murthy, Ravi; Mahvash, Armeen; Avritscher, Rony; McRae, Stephen; Sabir, Sharjeel; Wallace, Michael; Matin, Surena; Gupta, Sanjay

    2017-01-01

    PurposeTo describe the incidence of multiple renal artery pseudoaneurysms (PSA) in patients referred for renal artery embolization following partial nephrectomy and to study its relationship to RENAL nephrometry scores.Materials and MethodsThe medical records of 25 patients referred for renal artery embolization after partial nephrectomy were retrospectively reviewed for the following parameters: size and number of tumors, RENAL nephrometry scores, angiographic abnormalities, technical and clinical outcomes, and estimated glomerular filtration rates (eGFRs) after embolization.ResultsTwenty-four patients had primary renal tumors, while 1 patient had a pancreatic tumor invading the kidney. Multiple tumors were resected in 4 patients. Most patients (92 %) were symptomatic, presenting with gross hematuria, flank pain, or both. Angiography revealed PSA with (n = 5) or without (n = 20) AV fistulae. Sixteen patients (64 %) had multiple PSA involving multiple renal vessels. Higher RENAL nephrometry scores were associated with an increasing likelihood of multiple PSA. Multiple vessels were embolized in 14 patients (56 %). Clinical success was achieved after one (n = 22) or two (n = 3) embolization sessions in all patients. Post-embolization eGFR values at different time points after embolization were not significantly different from the post-operative eGFR.ConclusionA majority of patients requiring renal artery embolization following partial nephrectomy have multiple pseudoaneurysms, often requiring selective embolization of multiple vessels. Higher RENAL nephrometry score is associated with an increasing likelihood of multiple pseudoaneurysms. We found transarterial embolization to be a safe and effective treatment option with no long-term adverse effect on renal function in all but one patient with a solitary kidney.

  5. Multiple Renal Artery Pseudoaneurysms in Patients Undergoing Renal Artery Embolization Following Partial Nephrectomy: Correlation with RENAL Nephrometry Scores

    Energy Technology Data Exchange (ETDEWEB)

    Gupta, Nakul [Houston Methodist Hospital (United States); Patel, Anish [The University of Texas Southwestern Medical Center (United States); Ensor, Joe [Houston Methodist Research Institute, The Houston Methodist Cancer Center (United States); Ahrar, Kamran; Ahrar, Judy; Tam, Alda; Odisio, Bruno; Huang, Stephen; Murthy, Ravi; Mahvash, Armeen; Avritscher, Rony; McRae, Stephen; Sabir, Sharjeel; Wallace, Michael [The University of Texas MD Anderson Cancer Center, Department of Interventional Radiology (United States); Matin, Surena [The University of Texas MD Anderson Cancer Center, Department of Urology (United States); Gupta, Sanjay, E-mail: sgupta@mdanderson.org [The University of Texas MD Anderson Cancer Center, Department of Interventional Radiology (United States)

    2017-02-15

    PurposeTo describe the incidence of multiple renal artery pseudoaneurysms (PSA) in patients referred for renal artery embolization following partial nephrectomy and to study its relationship to RENAL nephrometry scores.Materials and MethodsThe medical records of 25 patients referred for renal artery embolization after partial nephrectomy were retrospectively reviewed for the following parameters: size and number of tumors, RENAL nephrometry scores, angiographic abnormalities, technical and clinical outcomes, and estimated glomerular filtration rates (eGFRs) after embolization.ResultsTwenty-four patients had primary renal tumors, while 1 patient had a pancreatic tumor invading the kidney. Multiple tumors were resected in 4 patients. Most patients (92 %) were symptomatic, presenting with gross hematuria, flank pain, or both. Angiography revealed PSA with (n = 5) or without (n = 20) AV fistulae. Sixteen patients (64 %) had multiple PSA involving multiple renal vessels. Higher RENAL nephrometry scores were associated with an increasing likelihood of multiple PSA. Multiple vessels were embolized in 14 patients (56 %). Clinical success was achieved after one (n = 22) or two (n = 3) embolization sessions in all patients. Post-embolization eGFR values at different time points after embolization were not significantly different from the post-operative eGFR.ConclusionA majority of patients requiring renal artery embolization following partial nephrectomy have multiple pseudoaneurysms, often requiring selective embolization of multiple vessels. Higher RENAL nephrometry score is associated with an increasing likelihood of multiple pseudoaneurysms. We found transarterial embolization to be a safe and effective treatment option with no long-term adverse effect on renal function in all but one patient with a solitary kidney.

  6. Atherosclerotic ischemic renal disease. Diagnosis and prevalence in an hypertensive and/or uremic elderly population

    Directory of Open Access Journals (Sweden)

    Rossi Michele

    2003-02-01

    Full Text Available Abstract Background Atherosclerotic ischemic renal disease is a frequent cause of end-stage renal failure leading to dialysis among the elderly; Its prevalence is inferred from autopsy or retrospective arteriographic studies. This study has been conducted on 269 subjects over 50 with hypertension and/or CRF, unrelated to other known causes of renal disease. Methods All 269 patients were studied either by color-flow duplex sonography (n = 238 or by renal scintigraphy (n = 224, and 199 of the 269 patients were evaluated using both of these techniques. 40 patients, found to have renal artery stenosis (RAS, were subjected to 3D-contrast enhancement Magnetic Resonance Angiography (MRA and/or Selective Angiography (SA. An additional 23 cases, negative both to scintigraphy and to ultrasound study, underwent renal angiography (MRA and/or SA. Results Color-duplex sonography, carried out in 238 patients, revealed 49 cases of RAS. MR or SA was carried out in 35 of these 49 patients, and confirmed the diagnosis in 33. Color-duplex sonography showed a PPV value of 94.3% and NPV of 87.0% while renal scintigraphy, carried out in 224 patients, had a PPV of 72.2% and a NPV of 29.4%. Patients with RAS showed a higher degree of renal insufficiency compared to non stenotic patients while there were no differences in proteinuria. RAS, based on color-duplex sonography studies, was present in 11% of patients in the age group 50–59, 18% in the 60–69 and 23% at age 70 and above. Conclusions A relatively large percentage of the elderly population with renal insufficiency and/or hypertension is affected by RAS and is at risk of developing end-stage renal failure. Color-duplex ultrasonography is a valid routine method of investigation of population at risk for renal artery stenosis.

  7. Frequency and clinical predictors of coronary artery disease in chronic renal failure renal transplant candidates.

    Science.gov (United States)

    de Albuquerque Seixas, Emerson; Carmello, Beatriz Leone; Kojima, Christiane Akemi; Contti, Mariana Moraes; Modeli de Andrade, Luiz Gustavo; Maiello, José Roberto; Almeida, Fernando Antonio; Martin, Luis Cuadrado

    2015-05-01

    Cardiovascular diseases are major causes of mortality in chronic renal failure patients before and after renal transplantation. Among them, coronary disease presents a particular risk; however, risk predictors have been used to diagnose coronary heart disease. This study evaluated the frequency and importance of clinical predictors of coronary artery disease in chronic renal failure patients undergoing dialysis who were renal transplant candidates, and assessed a previously developed scoring system. Coronary angiographies conducted between March 2008 and April 2013 from 99 candidates for renal transplantation from two transplant centers in São Paulo state were analyzed for associations between significant coronary artery diseases (≥70% stenosis in one or more epicardial coronary arteries or ≥50% in the left main coronary artery) and clinical parameters. Univariate logistic regression analysis identified diabetes, angina, and/or previous infarction, clinical peripheral arterial disease and dyslipidemia as predictors of coronary artery disease. Multiple logistic regression analysis identified only diabetes and angina and/or previous infarction as independent predictors. The results corroborate previous studies demonstrating the importance of these factors when selecting patients for coronary angiography in clinical pretransplant evaluation.

  8. Clinical outcomes of endovascularly managed iatrogenic renal hemorrhages

    International Nuclear Information System (INIS)

    Chiramel, George Koshy; Keshava, Shyamkumar Nidugala; Moses, Vinu; Kekre, Nitin; Tamilarasi, V; Devasia, Anthony

    2015-01-01

    To evaluate the effectiveness of endovascular management in iatrogenic renal injuries with regard to clinical status on follow-up and requirements for repeat angiography and embolization. This retrospective study included patients who were referred for endovascular management of significant hemorrhage following an iatrogenic injury. Data was recorded from the Picture Archiving and Communication system (PACS) and electronic medical records. The site and type of iatrogenic injury, imaging findings, treatment, angiography findings, embolization performed, clinical status on follow-up, and requirement for repeat embolization were recorded. The outcomes were clinical resolution, nephrectomy, or death. Clinical findings were recorded on follow-up visits to the clinic. Statistical analysis was performed using descriptive statistics. Seventy patients were included in this study between January 2000 and June 2012. A bleeding lesion (a pseudoaneurysm or arteriovenous fistula) was detected during the first angiogram in 55 patients (78.6%) and was selectively embolized. Fifteen required a second angiography as there was no clinical improvement and five required a third angiography. Overall, 66 patients (94.3%) showed complete resolution and 4 patients (5.7%) died. Three patients (4.3%) underwent nephrectomy for clinical stabilization even after embolization. There were no major complications. The two minor complications resolved spontaneously. Angiography and embolization is the treatment of choice in iatrogenic renal hemorrhage. Upto 20% of initial angiograms may not reveal the bleed and repeat angiography is required to identify a recurrent or unidentified bleed. The presence of multiple punctate bleeders on angiography suggests an enlarging subcapsular hematoma and requires preoperative embolization and nephrectomy

  9. Digital subtraction angiography (DSA)

    International Nuclear Information System (INIS)

    Ludwig, J.W.; Eikelboom, B.C.; Van Schaik, C.C.; Taams, A.J.; Teeuwen, C.

    1985-01-01

    Besides the non-invasive techniques, angiography remains essential. The disadvantages of angiography are the complexity of the procedure and the possibility of complications. Digital subtraction angiography (DSA) is a considerable improvement in the examination of vessels. In DSA, subtraction combined with enhancement of the signals allows the use of intravenous injection to obtain good images of the arteries. However, when the contrast material is supplied intravenously, a rather large amount of contrast material is necessary to obtain images of good quality. Quantities of 30-40 cc of contrast material are required. The advantage of the intravenous injection of contrast material rather than the use of a catheter to deliver the contrast material in loco is that it is almost non-invasive thus circumventing the complications caused by catheter manipulation in the arterial system. This makes it possible to apply this method on an out-patient basis. DSA can also be applied with intra-arterial selective injection of the contrast material. In this case, the strong enhancement with DSA allows the use of a small quantity of contrast material while still obtaining images of the vessels with good contrast definition

  10. Hemodynamic Measurements for the Selection of Patients With Renal Artery Stenosis: A Systematic Review

    NARCIS (Netherlands)

    van Brussel, Peter M.; van de Hoef, Tim P.; de Winter, Robbert J.; Vogt, Liffert; van den Born, Bert-Jan

    2017-01-01

    Interventions targeting renal artery stenoses have been shown to lower blood pressure and preserve renal function. In recent studies, the efficacy of catheter-based percutaneous transluminal renal angioplasty with stent placement has been called into question. In the identification of functional

  11. Selective Cannabinoid 2 Receptor Stimulation Reduces Tubular Epithelial Cell Damage after Renal Ischemia-Reperfusion Injury.

    Science.gov (United States)

    Pressly, Jeffrey D; Mustafa, Suni M; Adibi, Ammaar H; Alghamdi, Sahar; Pandey, Pankaj; Roy, Kuldeep K; Doerksen, Robert J; Moore, Bob M; Park, Frank

    2018-02-01

    Ischemia-reperfusion injury (IRI) is a common cause of acute kidney injury (AKI), which is an increasing problem in the clinic and has been associated with elevated rates of mortality. Therapies to treat AKI are currently not available, so identification of new targets that can be modulated to ameliorate renal damage upon diagnosis of AKI is essential. In this study, a novel cannabinoid receptor 2 (CB2) agonist, SMM-295 [3'-methyl-4-(2-(thiophen-2-yl)propan-2-yl)biphenyl-2,6-diol], was designed, synthesized, and tested in vitro and in silico. Molecular docking of SMM-295 into a CB2 active-state homology model showed that SMM-295 interacts well with key amino acids to stabilize the active state. In human embryonic kidney 293 cells, SMM-295 was capable of reducing cAMP production with 66-fold selectivity for CB2 versus cannabinoid receptor 1 and dose-dependently increased mitogen-activated protein kinase and Akt phosphorylation. In vivo testing of the CB2 agonist was performed using a mouse model of bilateral IRI, which is a common model to mimic human AKI, where SMM-295 was immediately administered upon reperfusion of the kidneys after the ischemia episode. Histologic damage assessment 48 hours after reperfusion demonstrated reduced tubular damage in the presence of SMM-295. This was consistent with reduced plasma markers of renal dysfunction (i.e., creatinine and neutrophil gelatinase-associated lipocalin) in SMM-295-treated mice. Mechanistically, kidneys treated with SMM-295 were shown to have elevated activation of Akt with reduced terminal deoxynucleotidyl transferase-mediated digoxigenin-deoxyuridine nick-end labeling (TUNEL)-positive cells compared with vehicle-treated kidneys after IRI. These data suggest that selective CB2 receptor activation could be a potential therapeutic target in the treatment of AKI. Copyright © 2018 by The American Society for Pharmacology and Experimental Therapeutics.

  12. Selective pharmacological modulation of renal peripheral-type benzodiazepine binding by treatment with diuretic drugs

    International Nuclear Information System (INIS)

    Lukeman, D.S.; Vaughn, D.A.; Fanestil, D.D.

    1988-01-01

    The authors have assessed the effects of in vivo administration of different classes of diuretic drugs on the expression of the peripheral-type benzodiazepine binding site (PBBS) in crude membranes derived from the cortex and outer medulla of rat kidney by saturation analysis with the PBBS-selective ligands [ 3 H]RO5-4864 and [ 3 H]PH 11195 in cortex and [ 3 H]RO5-4864 in outer medulla. Administration for 14-15 days of furosemide, a drug that blocks NaCl-KCl coupled transport in the thick ascending limb of the loop of Henle, produced a significant doubling in the PBBS density (B/sub max/) in outer medulla, a region of the kidney rich in thick ascending limbs, and produced a lesser but significant increase in PBBS density in the cortex. Conversely, administration for 14-15 days of the carbonic anhydrase inhibitor acetazolamide, which acts predominantly in the proximal tubule, and hydrochlorothiazide, which acts predominantly in the early distal tubule, elicited statistically significant increases in PBBS density in renal cortex but not in renal outer medulla. Furthermore, all drug treatments were without effect on the equilibrium dissociation constants (K/sub d/s) of [ 3 H]RO5-4864 and [ 3 H]PK 11195 binding to cortical and outer medullary membrane preparations. These findings demonstrate that the PBBS can be selectively up-regulated in different regions of the kidney by diuretic drugs with different modes/sites of action. 50 references, 1 table

  13. Selective renal vasoconstriction, exaggerated natriuresis and excretion rates of exosomic proteins in essential hypertension

    DEFF Research Database (Denmark)

    Damkjaer, M.; Jensen, Pia Hønnerup; Schwämmle, Veit

    2014-01-01

    AimIn essential hypertension (EH), the regulation of renal sodium excretion is aberrant. We hypothesized that in mild EH, (i) abnormal dynamics of plasma renin concentration (PRC) and atrial natriuretic peptide (ANP) are responsible for the exaggerated natriuresis, and (ii) exosomic protein...... patterns reflect the renal tubular abnormality involved in the dysregulation of sodium excretion. MethodsAfter 2-week drug washout and 4-day diet, systemic and renal hemodynamics, cardio-renal hormones, glomerular filtration and renal excretion were studied in male patients during saline loading (SL...

  14. Diagnostic and interventional angiography of superior mesenteric artery

    Energy Technology Data Exchange (ETDEWEB)

    Simonetti, G; Urigo, F; Canalis, G C; Guazzaroni, M; Caboni, M; Rossi, P; Passariello, R

    1986-01-01

    The widespread diffusion of digital imaging progressivaly reduces the indications to conventional angiography in all vascular districts. On the contrary, angiography of mesenteric arteries still works as a valid complementary diagnostic tool in granulomatous and neoplastic lesions of ileum. Today, in selected patients, angiography is the first diagnostic approach to vascular ischemic and hemorrhagic pathology of ileum; timely resort to interventional angiography improve a dramatic prognosis. 70 refs.

  15. CT Angiography for Living Kidney Donors: Accuracy, Cause of Misinterpretation and Prevalence of Variation

    Energy Technology Data Exchange (ETDEWEB)

    Chai, Jee Won; Lee, Whal; Yin, Yong Hu; Jae, Hwan Jun; Chung, Jin Wook; Park, Jae Hyung [Seoul National University Hospital, Seoul (Korea, Republic of); Kim, Hyeon Hoe [Seoul National University College of Medicine, Seoul (Korea, Republic of)

    2008-08-15

    To determine the accuracy of the use of multi-detector row CT (MDCT) to predict vascular anatomy in living kidney donors and to reveal the prevalence of vascular variations in a Korean population. A total of 153 living kidney donors that had undergone preoperative CT and nephrectomy, either with open or laparoscopic surgery, were selected retrospectively. The initial CT results were compared with the surgical findings and repeated review sessions of CT scans were performed to determine the causes of mismatches in discordant cases. The accuracy of CT angiography was 95% to predict the number of renal vessels. Four arteries and two veins were missed during the initial CT interpretation due to perception errors (for two arteries and two veins) and technical limitations (two arteries). The prevalence of multiple renal arteries and veins, early branching of a renal artery and late confluence of a renal vein were 31%, 5%, 12%, 17%, respectively. The circumaortic renal vein and the bilateral inferior vena cava were found in two cases each (1.3%). One case (0.7%) each of a retroaortic renal vein and a supradiaphragmatic originated renal artery were found. MDCT provides a reliable method to evaluate the vascular anatomy and variations of living kidney donors.

  16. CT Angiography for Living Kidney Donors: Accuracy, Cause of Misinterpretation and Prevalence of Variation

    International Nuclear Information System (INIS)

    Chai, Jee Won; Lee, Whal; Yin, Yong Hu; Jae, Hwan Jun; Chung, Jin Wook; Park, Jae Hyung; Kim, Hyeon Hoe

    2008-01-01

    To determine the accuracy of the use of multi-detector row CT (MDCT) to predict vascular anatomy in living kidney donors and to reveal the prevalence of vascular variations in a Korean population. A total of 153 living kidney donors that had undergone preoperative CT and nephrectomy, either with open or laparoscopic surgery, were selected retrospectively. The initial CT results were compared with the surgical findings and repeated review sessions of CT scans were performed to determine the causes of mismatches in discordant cases. The accuracy of CT angiography was 95% to predict the number of renal vessels. Four arteries and two veins were missed during the initial CT interpretation due to perception errors (for two arteries and two veins) and technical limitations (two arteries). The prevalence of multiple renal arteries and veins, early branching of a renal artery and late confluence of a renal vein were 31%, 5%, 12%, 17%, respectively. The circumaortic renal vein and the bilateral inferior vena cava were found in two cases each (1.3%). One case (0.7%) each of a retroaortic renal vein and a supradiaphragmatic originated renal artery were found. MDCT provides a reliable method to evaluate the vascular anatomy and variations of living kidney donors

  17. Magnetic resonance angiography for the head and neck region

    International Nuclear Information System (INIS)

    Aschenbach, R.; Esser, D.

    2004-01-01

    Magnetic resonance angiography is a noninvasive method in vascular imaging using noncontrast- enhanced and contrast-enhanced techniques. The contrast media used in contrast- enhanced magnetic resonance angiography are different from the X-ray contrast media and do not affect the thyroid gland or renal function. In detecting hypervascularized lesions in the head and neck, contrast-enhanced magnetic resonance angiography is the method of choice, which provides an acceptable quality in comparison to digital subtraction angiography. Future developments in magnetic resonance imaging techniques will cause a wider use of magnetic resonance angiography, especially in head and neck imaging. Digital subtraction angiography should therefore only be used in problem cases and for preoperative embolization [de

  18. MR angiography

    International Nuclear Information System (INIS)

    Masaryk, T.J.; Ross, J.S.

    1991-01-01

    This paper reports on preliminary research and recent clinical experience which indicates that MR angiography can play a role in routine scanning by providing useful information regarding the anatomy of the cerebral circulation. Used in conjunction with conventional spin-echo studies it may improve the overall sensitivity and specificity of MRI in a cost-effective fashion. It does not, however, replace conventional arteriography at this time for either extracranial or intracranial disease. The use of intravascular contrast agents with new fast-scan techniques also provides dynamic information regarding tissue perfusion in a fashion analogous to that of xenon CT. While this work is preliminary, and the exact agents and mathematical models have yet to be defined, the ability to perform parenchymal, angiographic, and physiologic imaging at a single setting is potentially very powerful. Clearly, the role of MR flow techniques deserves further investigation into possible technical refinements, so that accuracy relative to other diagnostic studies and impact upon patient management can be assessed in a meaningful way

  19. Microembolism after cerebral angiography

    International Nuclear Information System (INIS)

    Manaka, Hiroshi; Sakai, Hideki; Nagata, Izumi

    2000-01-01

    Acute microemboli are detected more precisely with the recently developed diffusion-weighted MR imaging (DWI). We happened to obtain 24 DWIs after 350 diagnostic cerebral angiographies in 1999. DWIs after cerebral angiographies showed bright lesions in 7 patients (28%), of whom 6 had no neurological symptoms after cerebral angiography. Seven of the 24 patients had risk factors for arteriosclerosis. Only one patient had embolic events due to angiography. Microemboli related to cerebral angiographies are inevitable in some patients. Most are silent, however, we should investigate the cause of microemboli and should make cerebral angiography safer. (author)

  20. Intravenous digital angiography for the detection of renovascular hypertension

    International Nuclear Information System (INIS)

    Dunnick, N.R.; Svetkey, L.; Braun, S.D.; Cohan, R.H.; Newman, G.E.; Himmelstein, S.I.; Klotman, P.E.

    1987-01-01

    In order to assess the accuracy of intravenous digital subtraction angiography (IV-DSA), the authors prospectively studied all patients referred for suspected renovascular hypertension with IV-DSA and conventional angiography. The IV-DSA study demonstrated renal artery stenosis in 25 patients. A significant main renal artery lesion was confirmed in 21 of these patients while four patients had either normal renal arteries or insignificant changes. The IV-DSA examination was considered negative for renal artery stenosis in 50 patients. This was confirmed in 49 patients, but one patient had a branch renal artery stenosis. The sensitivity of IV-DSA was 96% while the specificity was 93%. The negative predictive value was 98% and the positive predictive value 84%. IV-DSA provides good anatomic definition of the main renal arteries and is sufficiently sensitive to be used as a screening test for renovascular hypertension

  1. Angiography in angiology

    International Nuclear Information System (INIS)

    Zeitler, E.; Grosse-Vorholt, R.

    1980-01-01

    A review is given of recent developments in angiography including advances in the equipment, in the technique and in image processing. Indications for and interpretation of angiography are discussed and angiographic-therapeutic procedures are considered. (C.F.)

  2. Renal Denervation, Hope or Hype? : Studies on patient selection and mechanisms

    NARCIS (Netherlands)

    Vink, E.E.

    2014-01-01

    The general objective of this thesis was to determine which patients are most likely to benefit most from treatment with RDN and to study the effects of renal denervation (RDN). This thesis is subdivided into three parts. Part I focused on pathophysiologic studies on renal oxygenation and the

  3. Automated tube voltage selection for radiation dose and contrast medium reduction at coronary CT angiography using 3{sup rd} generation dual-source CT

    Energy Technology Data Exchange (ETDEWEB)

    Mangold, Stefanie [Medical University of South Carolina, Division of Cardiovascular Imaging, Department of Radiology and Radiological Science, Charleston, SC (United States); Eberhard-Karls University Tuebingen, Department of Diagnostic and Interventional Radiology, Tuebingen (Germany); Wichmann, Julian L. [Medical University of South Carolina, Division of Cardiovascular Imaging, Department of Radiology and Radiological Science, Charleston, SC (United States); University Hospital Frankfurt, Department of Diagnostic and Interventional Radiology, Frankfurt (Germany); Schoepf, U.J. [Medical University of South Carolina, Division of Cardiovascular Imaging, Department of Radiology and Radiological Science, Charleston, SC (United States); Medical University of South Carolina, Division of Cardiology, Department of Medicine, Charleston, SC (United States); Poole, Zachary B.; Varga-Szemes, Akos; De Cecco, Carlo N. [Medical University of South Carolina, Division of Cardiovascular Imaging, Department of Radiology and Radiological Science, Charleston, SC (United States); Canstein, Christian [Siemens Medical Solutions, Malvern, PA (United States); Caruso, Damiano [Medical University of South Carolina, Division of Cardiovascular Imaging, Department of Radiology and Radiological Science, Charleston, SC (United States); University of Rome ' ' Sapienza' ' , Department of Radiological Sciences, Oncology and Pathology, Rome (Italy); Bamberg, Fabian; Nikolaou, Konstantin [Eberhard-Karls University Tuebingen, Department of Diagnostic and Interventional Radiology, Tuebingen (Germany)

    2016-10-15

    To investigate the relationship between automated tube voltage selection (ATVS) and body mass index (BMI) and its effect on image quality and radiation dose of coronary CT angiography (CCTA). We evaluated 272 patients who underwent CCTA with 3{sup rd} generation dual-source CT (DSCT). Prospectively ECG-triggered spiral acquisition was performed with automated tube current selection and advanced iterative reconstruction. Tube voltages were selected by ATVS (70-120 kV). BMI, effective dose (ED), and vascular attenuation in the coronary arteries were recorded. Signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) were calculated. Five-point scales were used for subjective image quality analysis. Image quality was rated good to excellent in 98.9 % of examinations without significant differences for proximal and distal attenuation (all p ≥.0516), whereas image noise was rated significantly higher at 70 kV compared to ≥100 kV (all p <.0266). However, no significant differences were observed in SNR or CNR at 70-120 kV (all p ≥.0829). Mean ED at 70-120 kV was 1.5 ± 1.2 mSv, 2.4 ± 1.5 mSv, 3.6 ± 2.7 mSv, 5.9 ± 4.0 mSv, 7.9 ± 4.2 mSv, and 10.7 ± 4.1 mSv, respectively (all p ≤.0414). Correlation analysis showed a moderate association between tube voltage and BMI (r =.639). ATVS allows individual tube voltage adaptation for CCTA performed with 3{sup rd} generation DSCT, resulting in significantly decreased radiation exposure while maintaining image quality. (orig.)

  4. Experimental selective elevation of renal medullary blood flow in hypertensive rats: evidence against short-term hypotensive effect.

    Science.gov (United States)

    Bądzyńska, B; Sadowski, J

    2012-08-01

    Renal medullary blood flow (MBF) can be selectively increased by intrarenal or systemic infusion of bradykinin (Bk) in anaesthetized normotensive rats. We reproduced this effect in a number of rat models of arterial hypertension and examined whether increased perfusion of the renal medulla can cause a short-term decrease in blood pressure (BP) that is not mediated by increased renal excretion and depletion of body fluids. In uninephrectomized Sprague-Dawley rats, BP was elevated to approx. 145 mmHg by acute i.v. infusion of noradrenaline (NA) or angiotensin II (Ang II) (groups 1, 2), 2-week exposure to high-salt diet (3), high-salt diet + chronic low-dose infusion of Ang II using osmotic minipumps (4) or chronic high-dose Ang II infusion on normal diet (5). Uninephrectomized spontaneous hypertensive rats (SHR) were also examined (6,7). To selectively increase medullary perfusion, in anaesthetized rats, bradykinin was infused during 30-75 min into the renal medullary interstitium or intravenously. Bradykinin increased outer- and inner-medullary blood flow (laser-Doppler fluxes) by 10-20% in groups (1, 2), by 30-50% in groups (3, 4, 5) and approx. 20% in SHR (6, 7). The concurrent increase in total renal blood flow (Transonic probe) was < 3%. A minor (<3%) decrease in BP was seen only in rats acutely rendered hypertensive by NA or Ang II infusions; however, the decreases in BP and increases in medullary perfusion were not correlated. Thus, there was no evidence that in hypertensive rats, substantial selective increases in medullary perfusion can cause a short-term decrease in BP. © 2012 The Authors Acta Physiologica © 2012 Scandinavian Physiological Society.

  5. Diagnostic accuracy of C-arm CT during selective transcatheter angiography for hepatocellular carcinoma: comparison with intravenous contrast-enhanced, biphasic, dynamic MDCT

    Energy Technology Data Exchange (ETDEWEB)

    Higashihara, Hiroki; Osuga, Keigo; Onishi, Hiromitsu; Nakamoto, Atsushi; Tsuboyama, Takahiro; Maeda, Noboru; Hori, Masatoshi; Kim, Tonsok; Tomiyama, Noriyuki [Osaka University Graduate School of Medicine, Department of Diagnostic and Interventional Radiology, Suita, Osaka (Japan)

    2012-04-15

    This study was aimed to compare the accuracy, sensitivity, and positive predictive value of C-arm CT (CACT) during selective transcatheter angiography with those of multidetector CT (MDCT) in the detection of hepatocellular carcinoma (HCC). In this prospective study, 30 patients (mean age, 73 years) with unresectable HCC were examined with CACT before chemoembolisation. Images of a combination of CACT during arterial portography (CACTAP) and dual-phase CACT during hepatic arteriography (CACTHA) was obtained and images of intravenous contrast-enhanced, biphasic, dynamic, MDCT was also obtained beforehand. Three blinded observers independently reviewed CACT and MDCT. Diagnostic accuracy was evaluated by the alternative free-response receiver operating characteristic (AFROC) method. Sensitivities and positive predictive values (PPV) were analyzed with the paired t-test. In the mean area under the AFROC curve (Az), there was no significant difference between MDCT and CACT (MDCT, mean Az value, 0.83; CACT, 0.85, respectively) (P = 0.32). There was also no significant difference between the two techniques in sensitivity (MDCT, mean 0.65; CACT, 0.60) and PPV (MDCT, mean 0.98; CACT, 0.97) (P = 0.40, P = 0.68, respectively). The diagnostic accuracy of CACT was equivalent to that of biphasic CT in the diagnosis of HCC. (orig.)

  6. Transient acute renal failure and functional hemispheric depression after cerebral arteriography in diabetic patients

    DEFF Research Database (Denmark)

    Olsen, Tom Skyhøj; Lund, P; Praestholm, J

    1981-01-01

    Cerebral angiography was carried out in two diabetic patients in the evaluation of minor vascular ischemic episodes. A transient acute renal failure following cerebral angiography was accompanied by a transient comatose episode with severe unilateral neurological deficits. A functional depression...

  7. Catheter Angiography

    Medline Plus

    Full Text Available ... you will be admitted to the hospital overnight. Leave jewelry at home and wear loose, comfortable clothing. ... procedures such as chemoembolization or selective internal radiation therapy. identify dissection or splitting in the aorta in ...

  8. Catheter Angiography

    Medline Plus

    Full Text Available ... as the kidneys and liver) pelvis legs and feet arms and hands Physicians use the procedure to: ... procedures such as chemoembolization or selective internal radiation therapy. identify dissection or splitting in the aorta in ...

  9. Catheter Angiography

    Medline Plus

    Full Text Available ... or other procedures such as chemoembolization or selective internal radiation therapy. identify dissection or splitting in the ... days. Rarely, the catheter punctures the artery, causing internal bleeding. It also is possible that the catheter ...

  10. Gallbladder visualization on CT shortly after abdominal angiography with iodixanol

    International Nuclear Information System (INIS)

    Tajima, Hiroyuki; Murakami, Ryusuke; Goto, Shinsuke; Aoyama, Toshiya; Kaizu, Toshihide; Ichikawa, Taro; Kumazaki, Tatsuo; Onda, Masahiko

    1996-01-01

    Fifteen patients underwent CT examination shortly after abdominal angiography with iodixanol. Gallbladder opacification was observed in 13 patients in the absence of clinical evidence of renal impairment. Among them, 2 patients showed a strong opacification on CT. There was no significant relationship between visualization of the gallbladder and the total dose of contrast medium. Gallbladder opacification on CT examination shortly after angiography shows that the hepatobiliary tract is important in the excretion of iodixanol. (author)

  11. Saccular aneurysm of segmental branch of the main renal artery: approach to diagnosis and treatment

    International Nuclear Information System (INIS)

    Karaman, B.; Hamcan, S.; Bozkurt, Y.; Kara, K.; Aslan, A.

    2012-01-01

    Full text: Introduction: Renal artery aneurysms rarely detected clinical situation. Mostly determined by symptoms such as hematuria, hypertension and flank pain. Generally detected during investigation of symptoms or incidentally. Objectives and tasks: We aim to present the findings of CTA and DSA of the 58-year-old male patient with flank pain, hematuria and hypertension complaints. Materials and methods: We performed CTA and selective renal angiography to 58-year-old male patient with complaints of hypertension, flank pain and hematuria. Results: Approximately 11.5x 13.5 mm size of saccular aneurysm at the upper segmental branch of the left renal artery and focal cortical infarct detected in CT abdomen of the patient before treatment. The aneurysm was confirmed with selective renal angiography examination and treated with Cardiatis stent in the same procedure. Conclusion: Primary goal of treatment of renal artery aneurysms is to prevent complications such as rupture and thrombosis. Renal artery aneurysms have been treated with open surgery previously. Parenchyma preventive and minimally invasive treatments such as Cardiatis stent placement successfully uses currently

  12. Diagnostic use of angiotensin converting enzyme (ACE)-inhibited renal scintigraphy in the identification of selective renal artery stenosis in the presence of multiple renal arteries: A case report

    International Nuclear Information System (INIS)

    Morton, K.A.; Rose, S.C.; Haakenstad, A.O.; Handy, J.E.; Scuderi, A.J.; Datz, F.L.

    1990-01-01

    In patients with renovascular hypertension, it is unknown whether the angiotensin converting enzyme-(ACE) inhibited renal scan will identify stenosis of a segmental branch of a single renal artery or of an accessory artery where multiple renal arteries are present. Since multiple renal arteries may be present in approximately 25% of all individuals, it will be important to establish whether the ACE-inhibited renal scan is useful in this population. We report a case of stenosis involving a renal artery in a patient with multiple renal arteries, successfully identified by ACE-inhibited renal scintigraphy

  13. Renal Branch Artery Stenosis

    DEFF Research Database (Denmark)

    Andersson, Zarah; Thisted, Ebbe; Andersen, Ulrik Bjørn

    2017-01-01

    Renovascular hypertension is a common cause of pediatric hypertension. In the fraction of cases that are unrelated to syndromes such as neurofibromatosis, patients with a solitary stenosis on a branch of the renal artery are common and can be diagnostically challenging. Imaging techniques...... that perform well in the diagnosis of main renal artery stenosis may fall short when it comes to branch artery stenosis. We report 2 cases that illustrate these difficulties and show that a branch artery stenosis may be overlooked even by the gold standard method, renal angiography....

  14. Non-enhanced 3D MR angiography of the lower extremity using ECG-gated TSE imaging with non-selective refocusing pulses. Initial experience

    International Nuclear Information System (INIS)

    Lanzman, R.S.; Blondin, D.; Orzechowski, D.; Scherer, A.; Moedder, U.; Kroepil, P.; Godehardt, E.

    2010-01-01

    Purpose: To evaluate non-enhanced 3D MR angiography using turbo spin echo (TSE) imaging with non-selective refocusing pulses (NATIVE SPACE MRA) for the visualization of the arteries of the lower extremity. Materials and Methods: Three-station imaging (iliac arteries, femoral arteries, arteries of the lower leg) was performed in 8 healthy volunteers and 3 patients with peripheral artery disease (PAD) using a 1.5 T MR scanner. In 8 healthy volunteers, 4 different acquisition schemes were performed with the following imaging parameters: S 1: acquisition with every heartbeat (RR = 1), spoiler gradient of 25 % (SG = 25 %); S 2: RR = 1, SG = 0 %; S 3: RR = 2, SG = 25 %; S 4: RR = 2, SG = 0 %. The subjective image quality on a 4-point-scale (4 = excellent to 1 = not diagnostic) and relative SNR were assessed. In 3 patients with peripheral artery disease (PAD), SPACE MRA was performed for assessment of stenosis. Results: The mean subjective image quality was significantly lower for the iliac arteries compared to the femoral arteries and arteries of the lower leg (p < 0.0001). The subjective image quality for acquisition scheme S 1 was significantly lower than the image quality for S 3 and S 4 for the iliac arteries (p < 0.01), while the subjective image quality for acquisition scheme S 2 was significantly lower than S 3 and S 4 for the femoral arteries and the arteries of the lower leg (p < 0.01). The relative SNR was significantly higher for acquisition schemes S 3 and S 4 as compared to S 1 and S 2 (p < 0.0001) for all regions. SPACE MRA disclosed 7 significant stenoses in 3 PAD patients. Conclusion: ECG-gated SPACE MRA is a promising imaging technique for non-enhanced assessment of the arteries of the lower extremity. (orig.)

  15. Complications with Outpatient Angiography and Interventional Procedures

    International Nuclear Information System (INIS)

    Young, Noel; Chi, Ka-Kit; Ajaka, Joe; McKay, Lesa; O'Neill, Diane; Wong, Kai Ping

    2002-01-01

    Purpose: To prospectively identify the complications, and rates of complication, in outpatient angiography and interventional procedures. Methods: There were 1050 consecutive patients, 646 men and 404 women, aged 17-89 years, with a total of 1239 procedures studied in a 2-year period, 1997 to 1999. Results: There were 560 cases of aorto-femoral angiography,resulting in 124 complications (22%), with pain or hematoma in 110.There were 206 cases of neck and cerebral angiography, resulting in 51 complications (25%), with pain and hematoma in 34, transient ischemic attack in 2 and cerebrovascular accident in 1. There were 197 interfentional procedures, with 177 being balloon dilatations, resulting in 68 complications (35%), with 2 having hematomas and 1 having hematoma/abscess requiring active treatment. There were 276 cases having various 'other' procedures (e.g., renal angiography),resulting in 65 complications (24%), with pain and hematoma in 61. No procedure-related death occurred. Eighteen cases (1.5%) had significant complications, with contrast allergy in eight. Conclusion: Outpatient angiography and intervention are relatively safe, with low significant complication rates

  16. Renal artery denervation for treating resistant hypertension : definition of the disease, patient selection and description of the procedure.

    Science.gov (United States)

    Volpe, Massimo; Rosei, Enrico Agabiti; Ambrosioni, Ettore; Cottone, Santina; Cuspidi, Cesare; Borghi, Claudio; De Luca, Nicola; Fallo, Francesco; Ferri, Claudio; Mancia, Giuseppe; Morganti, Alberto; Muiesan, Maria Lorenza; Sarzani, Riccardo; Sechi, Leonardo; Tocci, Giuliano; Virdis, Agostino

    2012-12-01

    Arterial hypertension is responsible for a significant burden of cardiovascular morbidity and mortality, worldwide. Although several rational and integrated pharmacological strategies are available, the control of high blood pressure still remains largely unsatisfactory. Failure to achieve effective blood pressure control in treated hypertensive patients may have a substantial impact on individual global cardiovascular risk, since it significantly increases the risk of developing hypertension-related macrovascular and microvascular complications. Arterial hypertension is arbitrarily defined as 'resistant' or 'refractory' when the recommended blood pressure goals (clinic blood pressure below 140/90 mmHg or below 130/80 mmHg in patients with type 2 diabetes mellitus or nephropathy) are not achieved in the presence of a therapeutic strategy that includes lifestyle changes and at least three classes of antihypertensive drugs, including a diuretic, at adequate doses. Recently, an innovative non-pharmacological option has become available for treating resistant hypertension. Sympathetic denervation of renal arteries is a minimally invasive procedure that is performed via percutaneous access from the femoral artery. It consists of radiofrequency ablation of the afferent and efferent nerves of the renal sympathetic nervous system, with consequent isolation of renal parenchymal and juxtaglomerular structures from abnormal stimulation of the efferent adrenergic system. The present position paper of the Italian Society of Hypertension (SIIA) offers a diagnostic and therapeutic approach for the proper identification and effective clinical management of patients with resistant hypertension, who are candidates for renal artery denervation. These indications may have important implications not only from a clinical point of view, but also from an economic point of view, since a proper identification of patients with true resistant hypertension and an accurate selection of patients

  17. Renal denervation: Results of a single-center cohort study

    International Nuclear Information System (INIS)

    Luetkens, J.A.; Thomas, D.; Doerner, J.; Schild, H.H.; Naehle, C.P.; Woitas, R.P.; Hundt, F.

    2015-01-01

    To investigate the effect of renal denervation on office-based and 24-h ambulatory blood pressure measurements (ABPM) in a highly selective patient population with drug-resistant hypertension. Patients with drug resistant hypertension eligible for renal denervation were included in the study population. Office blood pressure and ABPM were assessed prior to and after renal denervation. To detect procedure related renal or renal artery damage, magnetic resonance imaging (MRI) and angiography (MRA) were performed pre-interventional, one day post-interventional, and one month after renal denervation. Mean follow-up time between renal denervation and blood pressure re-assessment was 9.5 ± 3.9 months. Between August 2011 and March 2013, 17 patients prospectively underwent renal denervation. Pre-interventional mean office blood pressure and ABPM were 177.3 ± 20.3/103.8 ± 20.4 mmHg and 155.2 ± 20.5/93.7 ± 14.5 mmHg, respectively. Post-interventional, office blood pressure was significantly reduced to 144.7 ± 14.9/89.5 ± 12.1 (p 0.05). The number of prescribed antihypertensive drugs was unchanged after renal denervation (4.7 ± 2.0 vs. 4.2 ± 1.2, p = 0.18). No renovascular complications were detected in follow-up MRI. After renal denervation, no significant decrease in ABPM was observed. These results may indicate a limited impact of renal denervation for drug resistant hypertension.

  18. Individual selection of X-ray tube settings in computed tomography coronary angiography: Reliability of an automated software algorithm to maintain constant image quality.

    Science.gov (United States)

    Durmus, Tahir; Luhur, Reny; Daqqaq, Tareef; Schwenke, Carsten; Knobloch, Gesine; Huppertz, Alexander; Hamm, Bernd; Lembcke, Alexander

    2016-05-01

    To evaluate a software tool that claims to maintain a constant contrast-to-noise ratio (CNR) in high-pitch dual-source computed tomography coronary angiography (CTCA) by automatically selecting both X-ray tube voltage and current. A total of 302 patients (171 males; age 61±12years; body weight 82±17kg, body mass index 27.3±4.6kg/cm(2)) underwent CTCA with a topogram-based, automatic selection of both tube voltage and current using dedicated software with quality reference values of 100kV and 250mAs/rotation (i.e., standard values for an average adult weighing 75kg) and an injected iodine load of 222mg/kg. The average radiation dose was estimated to be 1.02±0.64mSv. All data sets had adequate contrast enhancement. Average CNR in the aortic root, left ventricle, and left and right coronary artery was 15.7±4.5, 8.3±2.9, 16.1±4.3 and 15.3±3.9 respectively. Individual CNR values were independent of patients' body size and radiation dose. However, individual CNR values may vary considerably between subjects as reflected by interquartile ranges of 12.6-18.6, 6.2-9.9, 12.8-18.9 and 12.5-17.9 respectively. Moreover, average CNR values were significantly lower in males than females (15.1±4.1 vs. 16.6±11.7 and 7.9±2.7 vs. 8.9±3.0, 15.5±3.9 vs. 16.9±4.6 and 14.7±3.6 vs. 16.0±4.1 respectively). A topogram-based automatic selection of X-ray tube settings in CTCA provides diagnostic image quality independent of patients' body size. Nevertheless, considerable variation of individual CNR values between patients and significant differences of CNR values between males and females occur which questions the reliability of this approach. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  19. Achieving consistent image quality and overall radiation dose reduction for coronary CT angiography with body mass index-dependent tube voltage and tube current selection

    International Nuclear Information System (INIS)

    Wang, G.; Gao, J.; Zhao, S.; Sun, X.; Chen, X.; Cui, X.

    2014-01-01

    Aim: To develop a quantitative body mass index (BMI)-dependent tube voltage and tube current selection method for obtaining consistent image quality and overall dose reduction in computed tomography coronary angiography (CTCA). Methods and materials: The images of 190 consecutive patients (group A) who underwent CTCA with fixed protocols (100 kV/193 mAs for 100 patients with a BMI of <27 and 120 kV/175 mAs for 90 patients with a BMI of >27) were retrospectively analysed and reconstructed with an adaptive statistical iterative reconstruction (ASIR) algorithm at 50% blending. Image noise was measured and the relationship to BMI was studied to establish BMI-dependent tube current for obtaining CTCA images with user-specified image noise. One hundred additional cardiac patients (group B) were examined using prospective triggering with the BMI-dependent tube voltage/current. CTCA image-quality score, image noise, and effective dose from groups B and C (subgroup of A of 100 patients examined with prospective triggering only) were obtained and compared. Results: There was a linear relationship between image noise and BMI in group A. Using a BMI-dependent tube current in group B, an average CTCA image noise of 27.7 HU (target 28 HU) and 31.7 HU (target 33 HU) was obtained for the subgroups of patients with BMIs of >27 and of <27, respectively, and was independent of patient BMI. There was no difference between image-quality scores between groups B and C (4.52 versus 4.60, p > 0.05). The average effective dose for group B (2.56 mSv) was 42% lower than group C (4.38 mSv; p < 0.01). Conclusion: BMI-dependent tube voltage/current selection in CTCA provides an individualized protocol that generates consistent image quality and helps to reduce overall patient radiation dose. - Highlights: • BMI-dependent kVp and mA selection method may be established in CCTA. • BMI-dependent kVp and mA enables consistent CCTA image quality. • Overall dose reduction of 40% can

  20. The Evaluation of Angiotensin-Converting Enzyme Inhibitors in Renal Elimination with Selected Molecular Descriptors

    Directory of Open Access Journals (Sweden)

    Trbojevic Jovana

    2017-06-01

    Full Text Available Angiotensin-converting enzyme (ACE inhibitors modulate the function of the renin-angiotensin-aldosterone system, and they are commonly prescribed antihypertensive drugs especially in patients with renal failure. In this study, the relationships between several molecular properties of eight ACE inhibitors (enalapril, quinapril, fosinopril, ramipril, benazepril, perindopril, moexipril, trandolapril and their renal elimination data, from relevant literature, were investigated. The ’molecular descriptors of the ACE inhibitors, which included aqueous solubility data (logS; an electronic descriptor, polar surface area (PSA;, a constitutional parameter, molecular mass (Mr; and a geometric descriptor, volume value (Vol, as well as lipophilicity descriptors (logP values, were calculated using different software packages. Simple linear regression analysis showed the best correlation between renal elimination data and lipophilicity descriptor AClogP values (R2 = 0.5742. In the next stage of the study, multiple linear regression was applied to assess a higher correlation between the ACE inhibitors’ renal elimination data and lipophilicity, AClogP, with one additional descriptor as an independent variable. Good correlations were established between renal elimination data from the literature and the AClogP lipophilicity descriptor using the constitutional parameter (molecular mass (R2 = 0.7425 or the geometric descriptor (volume value (R2 = 0.7224 as an independent variable. The application of computed molecular descriptors in evaluating drug elimination is of great importance in drug research.

  1. Renal denervation: Results of a single-center cohort study; Renale Denervation. Ergebnisse einer Single-Center Kohortenstudie

    Energy Technology Data Exchange (ETDEWEB)

    Luetkens, J.A.; Thomas, D.; Doerner, J.; Schild, H.H.; Naehle, C.P. [Bonn Univ. (Germany). Dept. of Radiology; Wilhelm, K. [Johanniter Hospital, Bonn (Germany). Dept. of Radiology; Duesing, R. [Hypertension Center, Bonn (Germany); Woitas, R.P.; Hundt, F. [Bonn Univ. (Germany). Dept. of Internal Medicine I

    2015-01-15

    To investigate the effect of renal denervation on office-based and 24-h ambulatory blood pressure measurements (ABPM) in a highly selective patient population with drug-resistant hypertension. Patients with drug resistant hypertension eligible for renal denervation were included in the study population. Office blood pressure and ABPM were assessed prior to and after renal denervation. To detect procedure related renal or renal artery damage, magnetic resonance imaging (MRI) and angiography (MRA) were performed pre-interventional, one day post-interventional, and one month after renal denervation. Mean follow-up time between renal denervation and blood pressure re-assessment was 9.5 ± 3.9 months. Between August 2011 and March 2013, 17 patients prospectively underwent renal denervation. Pre-interventional mean office blood pressure and ABPM were 177.3 ± 20.3/103.8 ± 20.4 mmHg and 155.2 ± 20.5/93.7 ± 14.5 mmHg, respectively. Post-interventional, office blood pressure was significantly reduced to 144.7 ± 14.9/89.5 ± 12.1 (p < 0.05). ABPM values remained unchanged (147.9 ± 20.3/90.3 ± 15.6, p > 0.05). The number of prescribed antihypertensive drugs was unchanged after renal denervation (4.7 ± 2.0 vs. 4.2 ± 1.2, p = 0.18). No renovascular complications were detected in follow-up MRI. After renal denervation, no significant decrease in ABPM was observed. These results may indicate a limited impact of renal denervation for drug resistant hypertension.

  2. Magnetic resonance angiography (MRA)

    International Nuclear Information System (INIS)

    Arlart, I.P.; Guhl, L.

    1992-01-01

    An account is given in this paper of the physical and technical principles underlying the 'time-of-flight' technique for imaging of vessels by magnetic resonance tomography. Major indications for the new procedure of magnetic resonance angiography at present are intracerebral and extracerebral vessels, with digital subtraction angiography quite often being required to cope with minor alterations (small aneurysms, small occlusions). Magnetic resonance angiography and digital subtraction angiography are compared to each other for advantages and disadvantages. Basically, replacement of radiological angiography by magnetic resonance angiography appears to be possible only within limits, since X-ray diagnostics primarily provides morphological information about vessels, whereas flow dynamics is visualized by the 'time-of-flight' technique. (orig.) [de

  3. Cyclooxygenase-2 Selectively Controls Renal Blood Flow Through a Novel PPARβ/δ-Dependent Vasodilator Pathway.

    Science.gov (United States)

    Kirkby, Nicholas S; Sampaio, Walkyria; Etelvino, Gisele; Alves, Daniele T; Anders, Katie L; Temponi, Rafael; Shala, Fisnik; Nair, Anitha S; Ahmetaj-Shala, Blerina; Jiao, Jing; Herschman, Harvey R; Xiaomeng, Wang; Wahli, Walter; Santos, Robson A; Mitchell, Jane A

    2018-02-01

    Cyclooxygenase-2 (COX-2) is an inducible enzyme expressed in inflammation and cancer targeted by nonsteroidal anti-inflammatory drugs. COX-2 is also expressed constitutively in discreet locations where its inhibition drives gastrointestinal and cardiovascular/renal side effects. Constitutive COX-2 expression in the kidney regulates renal function and blood flow; however, the global relevance of the kidney versus other tissues to COX-2-dependent blood flow regulation is not known. Here, we used a microsphere deposition technique and pharmacological COX-2 inhibition to map the contribution of COX-2 to regional blood flow in mice and compared this to COX-2 expression patterns using luciferase reporter mice. Across all tissues studied, COX-2 inhibition altered blood flow predominantly in the kidney, with some effects also seen in the spleen, adipose, and testes. Of these sites, only the kidney displayed appreciable local COX-2 expression. As the main site where COX-2 regulates blood flow, we next analyzed the pathways involved in kidney vascular responses using a novel technique of video imaging small arteries in living tissue slices. We found that the protective effect of COX-2 on renal vascular function was associated with prostacyclin signaling through PPARβ/δ (peroxisome proliferator-activated receptor-β/δ). These data demonstrate the kidney as the principle site in the body where local COX-2 controls blood flow and identifies a previously unreported PPARβ/δ-mediated renal vasodilator pathway as the mechanism. These findings have direct relevance to the renal and cardiovascular side effects of drugs that inhibit COX-2, as well as the potential of the COX-2/prostacyclin/PPARβ/δ axis as a therapeutic target in renal disease. © 2018 The Authors.

  4. Renal arteriovenous shunts, fistulae and malformations - angiographic case reports

    International Nuclear Information System (INIS)

    Esser, P.W.; Duex, A.

    1989-01-01

    Individual case reports serve to demonstrate the pathogenetically different renal arteriovenous shunt formations, such as congenital arteriovenous angioma, spontaneous arteriovenous aneurysm, iatrogenic arterio-venous fistula and neoplasia-conditioned arteriovenous fistula. These are discussed in detail, including treatment possibilities. The ranking of digital subtraction angiography is emphasised. Our case reports show that in preoperative diagnosis of pathological structures in the kidney, renovasography is an invaluable tool, especially with i.a. DSA technique, and is superior to all other methods such as sonography, CT, MR and colour-coded Doppler sonography. Due to improved techniques of angiography (markedly lower amounts of contrast medium when using catheters of narrow lumen) indication for i.a. DSA in haematuria of unknown origin should be liberal. Above all, the method should be performed at an early stage. If there is a NAD renal finding in the i.a. DSA renovasogram in renally conditioned haematuria even when using a 1024 x 1024 image matrix, it is advisable to perform selective renal arteriography to either exclude or confirm the existence of an intrarenal angioma, additionally in conventional sheet film technique because of the superior power of resolution. (orig.) [de

  5. Transcatheter arterial ethanol embolization for congenital renal arteriovenous malformations

    International Nuclear Information System (INIS)

    Wang Jingbing; Wang Han; An Xiao; Wang Linchuan; Gao Liqiang; Zhou Zhiguo; Zhang Guixiang

    2010-01-01

    Objective: To discuss the effect and safety of trans-microcatheter arterial embolization with ethanol for the treatment of congenital renal arteriovenous malformations. Methods: Clinical data of 11 patients with congenital renal arteriovenous malformations manifested mainly as gross hematuria were retrospectively analyzed. Selective renal angiography was performed in all 11 patients. After the diagnosis was confirmed, super-selective catheterization of the diseased arteries was carried out and the trans-microcatheter arterial embolization with ethanol was conducted. Results: A total of 12 procedures were completed in 11 patients. The ethanol dose used in one procedure was 5-25 ml. Successful embolization of the congenital renal arteriovenous malformations was obtained in all patients. The gross hematuria disappeared within 24-48 hours after the treatment. Lumbago at treated side, low fever, abdominal distension, nausea, vomiting, etc. occurred within one week and no other serious complications developed. During the follow-up period lasting for 4-96 months, no recurrence of hematuria was observed and the renal function remained normal. Conclusion: Transcatheter arterial ethanol embolization is an economic, safe and effective treatment for congenital renal arteriovenous malformations. (authors)

  6. Multislice CT angiography

    Energy Technology Data Exchange (ETDEWEB)

    Prokop, Mathias E-mail: mathias.prokop@univie.ac.at

    2000-11-01

    Multislice CT has overcome past limitations of CT angiography (CTA): Scan length and spatial resolution can be simultaneously optimized with multislice CTA, contrast medium can be saved, and the evaluation of large anatomic areas and vessels smaller than 1 mm become possible. This article describes how to optimize scanning protocols and contrast injection, and discusses the main clinical applications of this new technique. Only three main scanning protocolssuffice for all indications. A high speed / high-volume protocol (using 4*2mm or 4*2.5mm collimation) can be employed to scan the chest or abdomen in 8-10s, or to cover the whole abdominal aorta and the peripheral runoff including the feet within 40-65s. A high resolution protocol (using 4*1mm or 4*1.25mm) can be employed for the aorta and most regional vascular beds. It allows for near isotrophic imaging and depicts fine vascular structures with excellent detail. Ultra-high resolution protocols (using 2*0.5mm or 4*0.5mm collimation) yield totally isotropic data sets, and are mainly reserved for cerebrovascular imaging. Image processing techniques, and, in particular, volume rendering have made image presentation faster and easier. Multislice CTA exceeds MRA in spatial resolution and is now able to display even small vascular side branches. Its main indications will be aortic diseases, suspected pulmonary embolism but also renal artery stenoses, preoperative workup of abdominal or cerebral vessels, and acute vascular diseases. Multisplice CTA will become a strong competitor of other minimally invasive vascular imaging techniques.

  7. Diagnostic accuracy of coronary CT angiography using 3{sup rd}-generation dual-source CT and automated tube voltage selection: Clinical application in a non-obese and obese patient population

    Energy Technology Data Exchange (ETDEWEB)

    Mangold, Stefanie [Medical University of South Carolina, Division of Cardiovascular Imaging, Department of Radiology and Radiological Science, Charleston, SC (United States); Eberhard-Karls University Tuebingen, Department of Diagnostic and Interventional Radiology, Tuebingen (Germany); Wichmann, Julian L. [Medical University of South Carolina, Division of Cardiovascular Imaging, Department of Radiology and Radiological Science, Charleston, SC (United States); University Hospital Frankfurt, Department of Diagnostic and Interventional Radiology, Frankfurt (Germany); Schoepf, U.J. [Medical University of South Carolina, Division of Cardiovascular Imaging, Department of Radiology and Radiological Science, Charleston, SC (United States); Medical University of South Carolina, Division of Cardiology, Department of Medicine, Charleston, SC (United States); Caruso, Damiano [Medical University of South Carolina, Division of Cardiovascular Imaging, Department of Radiology and Radiological Science, Charleston, SC (United States); University of Rome ' ' Sapienza' ' , Department of Radiological Sciences, Oncology and Pathology, Rome (Italy); Tesche, Christian [Medical University of South Carolina, Division of Cardiovascular Imaging, Department of Radiology and Radiological Science, Charleston, SC (United States); Heart Centre Munich-Bogenhausen, Department of Cardiology, Munich (Germany); Steinberg, Daniel H.; Bayer, Richard R. [Medical University of South Carolina, Division of Cardiology, Department of Medicine, Charleston, SC (United States); Varga-Szemes, Akos; Stubenrauch, Andrew C.; Biancalana, Matthew; De Cecco, Carlo N. [Medical University of South Carolina, Division of Cardiovascular Imaging, Department of Radiology and Radiological Science, Charleston, SC (United States); Nikolaou, Konstantin [Eberhard-Karls University Tuebingen, Department of Diagnostic and Interventional Radiology, Tuebingen (Germany)

    2017-06-15

    To investigate diagnostic accuracy of 3{sup rd}-generation dual-source CT (DSCT) coronary angiography in obese and non-obese patients. We retrospectively analyzed 76 patients who underwent coronary CT angiography (CCTA) and invasive coronary angiography. Prospectively ECG-triggered acquisition was performed with automated tube voltage selection (ATVS). Patients were dichotomized based on body mass index in groups A (<30 kg/m{sup 2}, n = 37) and B (≥30 kg/m{sup 2}, n = 39) and based on tube voltage in groups C (<120 kV, n = 46) and D (120 kV, n = 30). Coronary arteries were assessed for significant stenoses (≥50 % luminal narrowing) and diagnostic accuracy was calculated. Per-patient overall sensitivity, specificity, positive predictive value, negative predictive value (NPV) and accuracy were 96.9 %, 95.5 %, 93.9 %, 97.7 % and 96.1 %, respectively. Sensitivity and NPV were lower in groups B and D compared to groups A and C, but no statistically significant differences were observed (group A vs. B: sensitivity, 100.0 % vs. 93.3 %, p = 0.9493; NPV, 100 % vs. 95.5 %, p = 0.9812; group C vs. D: sensitivity, 100.0 % vs. 92.3 %, p = 0.8462; NPV, 100.0 % vs. 94.1 %, p = 0.8285). CCTA using 3{sup rd}-generation DSCT and (ATVS) provides high diagnostic accuracy in both non-obese and obese patients. (orig.)

  8. Diagnostic accuracy of coronary CT angiography using 3"r"d-generation dual-source CT and automated tube voltage selection: Clinical application in a non-obese and obese patient population

    International Nuclear Information System (INIS)

    Mangold, Stefanie; Wichmann, Julian L.; Schoepf, U.J.; Caruso, Damiano; Tesche, Christian; Steinberg, Daniel H.; Bayer, Richard R.; Varga-Szemes, Akos; Stubenrauch, Andrew C.; Biancalana, Matthew; De Cecco, Carlo N.; Nikolaou, Konstantin

    2017-01-01

    To investigate diagnostic accuracy of 3"r"d-generation dual-source CT (DSCT) coronary angiography in obese and non-obese patients. We retrospectively analyzed 76 patients who underwent coronary CT angiography (CCTA) and invasive coronary angiography. Prospectively ECG-triggered acquisition was performed with automated tube voltage selection (ATVS). Patients were dichotomized based on body mass index in groups A (<30 kg/m"2, n = 37) and B (≥30 kg/m"2, n = 39) and based on tube voltage in groups C (<120 kV, n = 46) and D (120 kV, n = 30). Coronary arteries were assessed for significant stenoses (≥50 % luminal narrowing) and diagnostic accuracy was calculated. Per-patient overall sensitivity, specificity, positive predictive value, negative predictive value (NPV) and accuracy were 96.9 %, 95.5 %, 93.9 %, 97.7 % and 96.1 %, respectively. Sensitivity and NPV were lower in groups B and D compared to groups A and C, but no statistically significant differences were observed (group A vs. B: sensitivity, 100.0 % vs. 93.3 %, p = 0.9493; NPV, 100 % vs. 95.5 %, p = 0.9812; group C vs. D: sensitivity, 100.0 % vs. 92.3 %, p = 0.8462; NPV, 100.0 % vs. 94.1 %, p = 0.8285). CCTA using 3"r"d-generation DSCT and (ATVS) provides high diagnostic accuracy in both non-obese and obese patients. (orig.)

  9. Comparison of angiography, prone renography, and exercise renography for treatment planning in hypertension

    International Nuclear Information System (INIS)

    Clorius, J.H.; Strauss, L.G.; Allenberg, J.; Hupp, T.; Schmidlin, P.; Irngartinger, G.

    1987-01-01

    Fifteen hypertensives with unilateral vascular stenosis had selective renal angiograms, prone-position gamma camera hippurate renograms, and upright exercise renograms. The exercise renograms were used to identify renal vasomotor dysfunction. Each procedure was assessed for its value to predict cure of hypertension. Therapy included one nephrectomy, and angioplasty, and 13 surgical revascularizations. Neither the extent of vascular lumen reduction as assessed with angiography nor the unilateral function impairment documented with a prone-position renogram contained useful prognostic data. Exercise renography correctly predicted the posttherapy blood pressure status in 14 of 15 hypertensives. Exercise renography can identify a newly recognized function response of the vasculature of the kidney, a pathologic response that shows promise in the investigation of hypertension

  10. [Renal denervation a treatment for resistant hypertension: a French experience].

    Science.gov (United States)

    Benamer, H; Mylotte, D; Garcia-Alonso, C; Unterseeh, T; Garot, P; Louvard, Y; Lefevre, T; Morice, M-C

    2013-12-01

    Arterial hypertension is the largest single contributor to global mortality, and is poorly controlled in approximately 50% of patients despite lifestyle and pharmacologic interventions. Randomized clinical trials have demonstrated that catheter-based renal sympathetic denervation reduces blood pressure (BP) in patients with resistant hypertension. We sought to evaluate the efficacy of this novel therapy in "Real World" clinical practice. Consecutive patients with treatment-resistant primary hypertension, as defined as home BP>160 mmHg despite treatment with ≥3 antihypertensive drugs, were selected for denervation following renal artery screening. Ambulatory and home BP monitoring was performed in all patients prior to and following percutaneous renal sympathetic denervation. In total, 35 patients were selected for catheter-based renal sympathetic denervation. The mean age was 63.6 ± 11.7 years, 37.1% were women, 37.1% were diabetic, and 11.4% had renal impairment (GFRdenervation was performed in 33/35 patients (1 renal artery stenosis on angiography [not ablated], 1 patient with renal artery spasm [unilateral denervation]), with an average 5.9 ± 1.6 ablations per renal artery. No procedural complications occurred. At 6 months, blood pressure was 15.5 ± 22.37/87.76 ± 13.97 mmHg (Prenal function was observed. Catheter-based renal denervation is safe and efficacious treatment, which results in significant reductions in blood pressure in patients with treatment-resistant hypertension, stable at 2 years follow-up. These results are applicable to real-world patient populations. Copyright © 2013 Elsevier Masson SAS. All rights reserved.

  11. Gastric and renal effects of COX-2 selective and non-selective NSAIDs in rats receiving low-dose aspirin therapy

    Directory of Open Access Journals (Sweden)

    Marcella Goetz MORO

    Full Text Available Abstract The consumption of low-dose aspirin (LDA to prevent cardiovascular disease continues to increase worldwide. Consequently, the number of chronic LDA users seeking dental procedures that require complementary acute anti-inflammatory medication has also grown. Considering the lack of literature evaluating this interaction, we analyzed the gastric and renal effects caused by a selective COX-2 inhibitor (etoricoxib and a non-selective COX-2 inhibitor (ibuprofen nonsteroidal anti-inflammatory drug (NSAID in rats receiving chronic LDA therapy. Male Wistar rats were divided into six experimental groups (carboxymethylcellulose (CMC - vehicle; LDA; LDA + ibuprofen; ibuprofen; LDA + etoricoxib; and etoricoxib and submitted to long-term LDA therapy with a subsequent NSAID administration for three days by gavage. After the experimental period, we analyzed gastric and renal tissues and quantified serum creatinine levels. The concomitant use of LDA with either NSAID induced the highest levels of gastric damage when compared to the CMC group (F = 20.26, p 0.05. These results suggest that even the acute use of an NSAID (regardless of COX-2 selectivity can induce gastric damage when combined with the long-term use of low-dose aspirin in an animal model. Additional studies, including clinical assessments, are thus needed to clarify this interaction, and clinicians should be careful of prescribing NSAIDs to patients using LDA.

  12. MDCT of renal and mesenteric vessels

    International Nuclear Information System (INIS)

    Fleischmann, D.

    2003-01-01

    Computed tomography angiography (CTA) with multiple detector-row CT (MDCT) has evolved into an established technique for non-invasive imaging of renal and mesenteric vessels. With adequate selection of acquisition parameters (thin collimation) high spatial-resolution volumetric data sets for subsequent 2D and 3D reformation can be acquired. Contrast medium (CM) injection parameters need to be adjusted to the acquisition speed of the scanners. Whereas fast acquisitions allow a reduction of total CM volume in the setting of CTA, this is not the case when CTA is combined with a second-phase abdominal MDCT acquisition for parenchymal (e.g., hepatic) imaging. Renal CTA is an accurate and reliable test for visualizing vascular anatomy and renal artery stenosis, and therefore a viable alternative to MRA in the assessment of patients with renovascular hypertension and in potential living related renal donors. CTA, combined with abdominal/parenchymal MDCT is a first-line diagnostic test in patients with suspected abdominal vascular emergencies, such as acute mesenteric ischemia, and an excellent tool to assess a wide variety of vascular abnormalities of the abdominal viscera. (orig.)

  13. MDCT of renal and mesenteric vessels

    Energy Technology Data Exchange (ETDEWEB)

    Fleischmann, D. [Dept. of Radiology, Stanford Univ. Medical Center, Stanford, CA (United States)

    2003-12-01

    Computed tomography angiography (CTA) with multiple detector-row CT (MDCT) has evolved into an established technique for non-invasive imaging of renal and mesenteric vessels. With adequate selection of acquisition parameters (thin collimation) high spatial-resolution volumetric data sets for subsequent 2D and 3D reformation can be acquired. Contrast medium (CM) injection parameters need to be adjusted to the acquisition speed of the scanners. Whereas fast acquisitions allow a reduction of total CM volume in the setting of CTA, this is not the case when CTA is combined with a second-phase abdominal MDCT acquisition for parenchymal (e.g., hepatic) imaging. Renal CTA is an accurate and reliable test for visualizing vascular anatomy and renal artery stenosis, and therefore a viable alternative to MRA in the assessment of patients with renovascular hypertension and in potential living related renal donors. CTA, combined with abdominal/parenchymal MDCT is a first-line diagnostic test in patients with suspected abdominal vascular emergencies, such as acute mesenteric ischemia, and an excellent tool to assess a wide variety of vascular abnormalities of the abdominal viscera. (orig.)

  14. Withanolides from Aeroponically Grown Physalis peruviana and Their Selective Cytotoxicity to Prostate Cancer and Renal Carcinoma Cells.

    Science.gov (United States)

    Xu, Ya-Ming; Wijeratne, E M Kithsiri; Babyak, Ashley L; Marks, Hanna R; Brooks, Alan D; Tewary, Poonam; Xuan, Li-Jiang; Wang, Wen-Qiong; Sayers, Thomas J; Gunatilaka, A A Leslie

    2017-07-28

    Investigation of aeroponically grown Physalis peruviana resulted in the isolation of 11 new withanolides, including perulactones I-L (1-4), 17-deoxy-23β-hydroxywithanolide E (5), 23β-hydroxywithanolide E (6), 4-deoxyphyperunolide A (7), 7β-hydroxywithanolide F (8), 7β-hydroxy-17-epi-withanolide K (9), 24,25-dihydro-23β,28-dihydroxywithanolide G (10), and 24,25-dihydrowithanolide E (11), together with 14 known withanolides (12-25). The structures of 1-11 were elucidated by the analysis of their spectroscopic data, and 12-25 were identified by comparison of their spectroscopic data with those reported. All withanolides were evaluated for their cytotoxic activity against a panel of tumor cell lines including LNCaP (androgen-sensitive human prostate adenocarcinoma), 22Rv1 (androgen-resistant human prostate adenocarcinoma), ACHN (human renal adenocarcinoma), M14 (human melanoma), SK-MEL-28 (human melanoma), and normal human foreskin fibroblast cells. Of these, the 17β-hydroxywithanolides (17-BHWs) 6, 8, 9, 11-13, 15, and 19-22 showed selective cytotoxic activity against the two prostate cancer cell lines LNCaP and 22Rv1, whereas 13 and 20 exhibited selective toxicity for the ACHN renal carcinoma cell line. These cytotoxicity data provide additional structure-activity relationship information for the 17-BHWs.

  15. Angiography of the upper extremity

    International Nuclear Information System (INIS)

    Janevski, B.K.

    1982-01-01

    This thesis provides a description of the technical and medical aspects of arteriography of the upper extremity and an extensive analysis of the angiographic anatomy and pathology of 750 selective studies performed in more than 500 patients. A short historical review is provided of angiography as a whole and of arteriography of the hand in particular. The method of percutaneous transfemoral catheterization of the arteries of the upper extremity and particularly the arteries of the hand is considered, discussing the problems the angiographer encounters frequently, describing the angiographic complications which may occur and emphasizing the measures to keep them to a minimum. The use of vasodilators in hand angiography is discussed. A short description of the embryological patterns persisting in the arteries of the arm is included in order to understand the congenital variations of the arteries of the upper extremity. The angiographic patterns and clinical aspects of the most common pathological processes involving the arteries of the upper extremities are presented. Special attention is paid to the correlation between angiography and pathology. (Auth.)

  16. Coronary CT angiography

    Energy Technology Data Exchange (ETDEWEB)

    Dewey, Marc [Charite - Universitaetsmedizin Berlin (Germany). Inst. fuer Radiologie

    2009-07-01

    Coronary CT angiography has attained increasing scientific attention at academic institutions and has become a highly accurate diagnostic modality. Extending this knowledge into a practice setting is the purpose of 'Coronary CT Angiography'. This book will assist you in integrating cardiac CT into your daily practice, while also giving an overview of the current technical status and applications. The specific features of scanners from all four main vendors are also presented providing an objective overview of noninvasive coronary angiography using CT. (orig.)

  17. Renal Artery Stenosis (RAS) Case study

    International Nuclear Information System (INIS)

    Zaater, M.K.

    2012-01-01

    Renal Artery Stenosis (RAS), is one of the causes of secondary hypertension; there are many causes of renal artery stenosis, as atherosclerosis of the renal artery which account for 90% of cases of RAS; fibromuscular dysplasia accounts for 10% of RAS. Various causes of thrombophilia either due congenital causes or acquired causes and can lead to RAS. Our patient was presented by acute attack of epistaxis and hypertension. Angiography of the Renal Arteries,are showed no sign of renal artery stenosis. However, the right kidney showed upper pole infarction, and the left kidney showed evidence of functional lower pole renal artery stenosis, although there is no anatomical stenosis detected in angiography. Work up for the cause of thrombophilia did not help in the diagnosis, which may be due to an undiscovered cause of thrombophilia

  18. Angiography - interventional diagnostic applications

    International Nuclear Information System (INIS)

    Schild, H.

    1994-01-01

    The angiography system is very different from the other systems used in diagnostic radiology. The invasivity of angiography requires special, high standards in theoretical and practical training and experience both of beginners and experienced personnel. This textbook fully meets the demand for in-depth and exhaustive information, as it presents: - The fundamentals and techniques of angiography, the vascular anatomy, and many hints and tips of great help in practice. - A comprehensive survey of diagnostic problems and examination approaches, including neuro-angiography, with 221 reproductions of original angiographs, and additional schematic representations. - A special chapter devoted to indication and relevant techniques for the major vascular interventional examinations. - A great number of tables explain at a glance standard examination techniques, indications and diagnostic criteria. (orig./CB) [de

  19. Angiography in portal hypertension

    Energy Technology Data Exchange (ETDEWEB)

    Zeitler, E

    1982-04-05

    We report on the cooperative possibilities the radiologist has as to diagnosis and therapy of portal hypertension. The catheter angiography allows to make a differentiation between pre- and intrahepatic bloc and the localization of bleeding esophagus varices. Only after all endoscopic measures with sclerotherapy and Laser coagulation have failed, catheter angiography will be carried out as a therapeutic measure. The future development, however, will give the opportunity to a series of therapeutic attempts on the field of interventional radiology.

  20. Angiography in portal hypertension

    International Nuclear Information System (INIS)

    Zeitler, E.

    1982-01-01

    We report on the cooperative possibilities the radiologist has as to diagnosis and therapy of portal hypertension. The catheter angiography allows to make a differentiation between pre- and intrahepatic bloc and the localization of bleeding esophagus varices. Only after all endoscopic measures with sclerotherapy and Laser coagulation have failed, catheter angiography will be carried out as a therapeutic measure. The future development, however, will give the opportunity to a series of therapeutic attempts on the field of interventional radiology. (orig.) [de

  1. Emergent endovascular embolization of iatrogenic renal vascular injuries

    International Nuclear Information System (INIS)

    Liu Fengyong; Wang Maoqiang; Duan Feng; Wang Zhijun; Wang Zhongpu

    2007-01-01

    Objective: To evaluate the efficacy and safety of the interventional techniques for emergent treatment of iatrogenic renal injuries. Methods: Nine patients with iatrogenic renal vascular injuries were treated with superselective renal arterial embolization. The causes of renal injury included post-renal biopsy in 5 patients, endovascular interventional procedure-related in 2, post-renal surgery in 1, and post-percutaneous nephrostomy in 1 patient. The patients presented clinically with hemodynamical unstability with blood loss shock in 7 patients, severe flank pain in 7, and hematuria in 8 patients. Perirenal hematoma was confirmed in 8 patients by CT and ultrasonography. The embolization materials used were microcoils in 7 and standard stainless steel coils in 2 patients, associated with polyvinyl alcohol particles (PVA) in 5, and gelfoam particles in 2 cases. Results: Renal angiogram revealed intra-renal arteriovenous fistula in 6 cases, intrarenal pseudoaneurysm in 2 cases, and the contrast media extravasation in 1 patient. The technical success of the arterial embolization was achieved in all 9 cases within a single session. All angiographies documented complete obliteration of the abnormal vessels together with all major intrarenal arterial branches maintaining patent. Seven patients with hemodynamically compromise experienced immediate relief of their blood loss related symptoms, and another 7 with severe flank pain got relief progressively.. Hematuria ceased in 8 patients within 2-14 days after the embolization and impairment of renal function occurred after the procedure in 5 cases, including transient aggravation (n=3 )and developed new renal dysfunction (n=2). Two of these patients required hemodialysis. Perirenal hematoma were gradually absorbed on ultrasonography during 2-4 months after the procedures. Follow-up time ranged from 6-78 months (mean, 38 months), 4 patients died of other primary diseases of renal and multi-organ failures. Five patients are

  2. The role of CT angiography in the evaluation of pediatric renovascular hypertension

    Energy Technology Data Exchange (ETDEWEB)

    Kurian, Jessica [The Perelman School of Medicine, University of Pennsylvania, Department of Radiology, The Children' s Hospital of Philadelphia, Philadelphia, PA (United States); The Children' s Hospital at Montefiore, Bronx, NY (United States); Epelman, Monica [The Perelman School of Medicine, University of Pennsylvania, Department of Radiology, The Children' s Hospital of Philadelphia, Philadelphia, PA (United States); Nemours Children' s Hospital, Department of Radiology, Orlando, FL (United States); Darge, Kassa; Nijs, Els [The Perelman School of Medicine, University of Pennsylvania, Department of Radiology, The Children' s Hospital of Philadelphia, Philadelphia, PA (United States); Meyers, Kevin [The Perelman School of Medicine, University of Pennsylvania, Division of Nephrology, The Children' s Hospital of Philadelphia, Philadelphia, PA (United States); Hellinger, Jeffrey C. [The Perelman School of Medicine, University of Pennsylvania, Department of Radiology, The Children' s Hospital of Philadelphia, Philadelphia, PA (United States); New York Cardiovascular Institute and Lenox Hill Radiology, New York, NY (United States)

    2013-04-15

    Historically, the evaluation of renovascular hypertension has been accomplished by US, renal scintigraphy and digital subtraction angiography. Based on its high accuracy reported in adults renal CT angiography (CTA) with pediatric-appropriate low radiation dose techniques has become an important tool in the workup of renovascular hypertension in children. Renal CTA has several advantages over more conventional imaging modalities, including rapid and non-invasive acquisition, high resolution and easy reproducibility. Additionally, in our experience high-quality renal CTA can be performed using low-dose radiation exposures and can be acquired without sedation in most instances. This article illustrates by examples the usefulness of renal CTA for diagnosis of childhood renovascular hypertension and provides an overview of renal CTA findings in the most common childhood renovascular diseases. (orig.)

  3. Radiation doses to patients from digital subtraction angiography

    International Nuclear Information System (INIS)

    Goni, H.; Tsalafoutas, I. A.; Tzortzis, G.; Pappas, P.; Bouzas, N.; Loulakas, J.; Georgiou, A.; Georgiou, E.; Yakoumakis, E. N.

    2005-01-01

    This investigation determined patient doses during digital subtraction angiography (DSA). Fluoroscopy time, dose-area product (DAP) and entrance surface air kerma (ESAK) were analysed from 263 DSA examinations, classified into seven categories: (1) abdominal aorta, iliac, femoral, popliteal and leg arteries; (2) abdominal aorta and super-selective DSA of renal arteries; (3) combination of (1) and (2); (4) super-selective DSA of common carotid and vertebral arteries, intracranial branches in face and profile projections; (5) super-selective DSA of hepatic, splenic, superior and inferior mesenteric arteries; (6) combination of (1) and (4); and (7) celiac trunk and branches. Median DAP values were 67.7, 92.9, 76.6, 53.6, 105.7, 76.1 and 2.6 Gy cm 2 , respectively. With the exception of one examination, ESAK values were below 2 Gy: the limit for erythema. Compared with published data, DAP values were within the range reported for (1) and (4), slightly larger for (2) and (5), whereas no references were identified for the remaining three categories. (authors)

  4. Angiography and angiotherapy of gastrointestinal tract bleeding

    Energy Technology Data Exchange (ETDEWEB)

    Soerensen, R.; Grassot, A.; Souchon, R.

    1982-03-01

    In selected patients with upper and lower gastrointestinal hemorrhage there is an indication for angiography. Vasoconstrictive drugs or embolization materials can be submitted through the catheter to stop the hemorrhage (angiotherapy). 81 patients were diagnosed by this method. Treatment through the angiographic catheter followed the diagnostic procedure in 41 cases. The hemorrhage was controlled in 36 patients.

  5. Diagnostic accuracy of coronary angiography with multislice computed tomography applied to 'the Real World'

    International Nuclear Information System (INIS)

    Rodriguez Granillo, Gaston A.; Rosales, Miguel A.; Llaurado, Claudio; Fernandez Pereira, Carlos; Garcia Carcia, Hector M.

    2006-01-01

    Objective: To assess the diagnostic accuracy of Coronary Angiography with Multislice Computed Tomography (MSCT) for the detection of significant coronary artery stenoses. Material and methods: Patients studied had an indication for diagnostic coronary angiography and no history of contrast allergies, renal failure or arrhythmias. A multislice tomography equipment (Brilliance 40, Philips, The Netherlands) with ECG gating was used for image acquisition. A total of 90-125 mI of iodinated contrast was administered by IV route. Obesity, diabetes, diffusely calcified segments with a diameter < 2.0 mm, and segments treated with stents were not considered exclusion criteria. Lesions were defined as significant when the decrease in Iumen was ≥ 50% by MSCT and quantitative coronary angiography (QCA). Results: A total of 38 patients were scanned before the intervention. Of them, one (3%) was excluded because of inadequate image quality. The remaining 37 patients (444 segments), with an adequate quality image, were included in the study (81% men, mean age 62.43 ± 12.5 years, 13.5% diabetics). Mean scan time was 15.12 ± 2.6 seconds, and 444 segments were assessed with both techniques. The number of lesions deemed significant by QCA and MSCT were 88 (17%) and 93 (18%), respectively. Sensitivity, specificity, positive and negative predictive values of MSCT to detect significant stenoses were 82%, 93%, 72% and 96%, respectively. Conclusion: In non-selected patients, coronary angiography by multislice computed tomography exhibits a high negative predictive value for the detection of obstructive coronary disease. (author)

  6. Intracranial MR angiography

    International Nuclear Information System (INIS)

    Davis, W.L.; Blatter, D.D.; Parker, D.L.; Robison, R.O.; Harnsberger, H.R.

    1991-01-01

    This paper compares the more traditional three-dimensional (3D) time-of-flight MR angiography with a novel new technique, MOTSA, in the evaluation of both normal and abnormal intracranial anatomy. The authors performed sequential, location-matched 3D TOF and MOTSA MR angiography in 10 subjects with normal and 25 with abnormal intracranial anatomy. Images were evaluated for visualization of specific vessels and depiction of pathologic anatomy. All images were subjected to an objective scoring system. Digital angiography was available in 15 of 25 abnormal cases. In the normal cases, large- and small-vessel visualization was improved. Significant improvement in visualization of venous anatomy was also observed. In the abnormal cases, pathologic anatomy was better visualized, providing important diagnostic information. Multiple overlapping thin-slab-acquisition MR angiography demonstrates vessel visualization that is increased over that of 3D TOF MR angiography in both normal and abnormal cases. Because of the decrease in saturation effects and phase dispersion, MOTSA is especially useful in the evaluation of complex intracranial vascular abnormalities

  7. Urine proteome analysis in Dent's disease shows high selective changes potentially involved in chronic renal damage.

    Science.gov (United States)

    Santucci, Laura; Candiano, Giovanni; Anglani, Franca; Bruschi, Maurizio; Tosetto, Enrica; Cremasco, Daniela; Murer, Luisa; D'Ambrosio, Chiara; Scaloni, Andrea; Petretto, Andrea; Caridi, Gianluca; Rossi, Roberta; Bonanni, Alice; Ghiggeri, Gian Marco

    2016-01-01

    Definition of the urinary protein composition would represent a potential tool for diagnosis in many clinical conditions. The use of new proteomic technologies allows detection of genetic and post-trasductional variants that increase sensitivity of the approach but complicates comparison within a heterogeneous patient population. Overall, this limits research of urinary biomarkers. Studying monogenic diseases are useful models to address this issue since genetic variability is reduced among first- and second-degree relatives of the same family. We applied this concept to Dent's disease, a monogenic condition characterised by low-molecular-weight proteinuria that is inherited following an X-linked trait. Results are presented here on a combined proteomic approach (LC-mass spectrometry, Western blot and zymograms for proteases and inhibitors) to characterise urine proteins in a large family (18 members, 6 hemizygous patients, 6 carrier females, and 6 normals) with Dent's diseases due to the 1070G>T mutation of the CLCN5. Gene ontology analysis on more than 1000 proteins showed that several clusters of proteins characterised urine of affected patients compared to carrier females and normal subjects: proteins involved in extracellular matrix remodelling were the major group. Specific analysis on metalloproteases and their inhibitors underscored unexpected mechanisms potentially involved in renal fibrosis. Studying with new-generation techniques for proteomic analysis of the members of a large family with Dent's disease sharing the same molecular defect allowed highly repetitive results that justify conclusions. Identification in urine of proteins actively involved in interstitial matrix remodelling poses the question of active anti-fibrotic drugs in Dent's patients. Copyright © 2015 Elsevier B.V. All rights reserved.

  8. The interventional treatment of acute renal infarction:clinical experience in six cases

    International Nuclear Information System (INIS)

    Wang Kai; Jiang Guomin; Zhao Jinwei; Li Shaoqin; Tian Feng; Huang Wenhua; Zhang Xianshun; Liu Yizhi

    2010-01-01

    Objective: To discuss the clinical characteristics of acute renal infarction and to evaluate the endovascular interventional therapy in treating acute renal infarction. Methods: Since 2006, six patients with acute renal infarction were encountered in our hospital. Renal arterial suction and thrombolytic therapy were immediately carried out as soon as the diagnosis was confirmed. The clinical data were retrospectively analyzed. Results: Based on clinical manifestations, enhanced CT scan and angiography, the diagnosis of acute renal infarction was definitely confirmed in all 6 patients. After renal arterial suction and thrombolytic therapy the clinical symptoms were markedly relieved and the blood flow in infracted area completely or partially returned to normal. Conclusion: The clinical presentation of acute renal infarction is not characteristic. For the diagnosis of acute renal infarction contrast-enhanced CT scanning and renal angiography are the exams of first choice. Renal artery suction and thrombolytic therapy is a safe and effective treatment for acute renal infarction. (authors)

  9. [Renal denervation for the treatment of resistant hypertension: definition, patient selection and description of the procedure. 2012 Position paper of the Italian Society of Hypertension].

    Science.gov (United States)

    Volpe, Massimo; Agabiti-Rosei, Enrico; Ambrosioni, Ettore; Cottone, Santina; Cuspidi, Cesare; Borghi, Claudio; De Luca, Nicola; Fallo, Francesco; Ferri, Claudio; Mancia, Giuseppe; Morganti, Alberto; Muiesan, Maria Lorenza; Sarzani, Riccardo; Sechi, Leonardo; Tocci, Giuliano; Virdis, Agostino

    2012-12-01

    Hypertension is responsible for a relevant burden of cardiovascular morbidity and mortality worldwide. Although several appropriate and integrated pharmacological strategies are available, blood pressure control still remains largely unsatisfactory. Failure to achieve effective blood pressure control in treated hypertensive patients may have a substantial impact on overall cardiovascular risk, since it significantly increases the risk of both macrovascular and microvascular complications. Hypertension is arbitrarily defined as "resistant" or "refractory" when recommended blood pressure goals (clinic blood pressure hypertension has recently become available. Renal sympathetic denervation is a minimally invasive procedure performed via femoral access that uses radiofrequency catheter ablation to disable renal sympathetic afferent and efferent nerves. It results in isolation of renal parenchymal and juxtaglomerular cells from the abnormal enhancement of renal adrenergic nerve activity. The present position paper of the Italian Society of Hypertension provides a diagnostic and therapeutic approach to the early identification and effective clinical management of patients with resistant hypertension, who may be candidates for renal denervation. These indications may have important implications not only from a clinical viewpoint but also from an economic perspective. The accurate identification of patients with resistant hypertension and the appropriate selection of patients eligible for this procedure may help improve blood pressure control and reduce the risk of cardiovascular and cerebrovascular complications in these patients.

  10. MR angiography (MRA)

    Energy Technology Data Exchange (ETDEWEB)

    Hasuo, Kanehiro [Kyushu Univ., Fukuoka (Japan). Faculty of Medicine

    1995-12-01

    The primary goal of vascular imaging is the visualization of morphology and hemodynamics. Catheter angiography has been regarded as a gold standard for this purpose. However, MR angiography (MRA) is now increasingly being recognized as an important noninvasive technique for the depiction of vascular diseases and is partially superseding catheter angiography. The author evaluated the usefulness of MRA in the diagnosis of cerebral aneurysms and moyamoya disease. All aneurysms 5 mm or larger in diameter could be detected and most of those less than 5 mm in diameter were also detectable with using a combination of MIP images, target MIP images and source images. In moyamoya disease, the diagnosis could be made in all. For hemodynamic changes, flow directions in the circle of Willis could be visualized by phase-contrast MRA in a normal volunteer. In addition, MRA successfully showed the patency of surgical collaterals in cases of moyamoya disease. Despite some limitations compared with catheter angiography, MRA has a high sensitivity and specificity in the diagnosis of cerebrovascular abnormalities. Furthermore, screening of cerebral aneurysms or cerebrovascular occlusive diseases seems to be a new, and important indication for MRA. (author).

  11. The value of 3D-CT angiography and duplex sonography in comparison to arteriography in carotid artery stenoses

    International Nuclear Information System (INIS)

    Link, J.; Mueller-Huelsbeck, S.; Wesner, F.; Hoepfner, M.; Schwarzenberg, H.; Heller, M.

    1997-01-01

    To determine the value of 3D-CT angiography, duplex sonography in comparison to selective digital subtraction angiography for evaluation of carotid artery stenoses. Methods: 30 patients with 51 stenoses of carotid artery underwent 3D-CT angiography, duplex sonography and angiography. Quantification of stenosis was determined according to the NASCET study and categorized into mild (0-29%), moderate (30-69%), severe (70-99%) and occluded (100%). Results: The agreement of 3D-CT angiography with intraarterial digital subtraction angiography (DSA) was 62% (r=0.89; p [de

  12. Coronary angiography using synchrotron radiation

    International Nuclear Information System (INIS)

    Akatsuka, Takao; Hiranaka, Yukio; Takeda, Tohru; Hyodo, Kazuyuki.

    1990-01-01

    Invasive coronary angiography is the imaging technique of choice for diagnosis of ischemic heart disease. Recently, the application of synchrotron radiation in coronary angiography has been investigated in the world, with the aim of developing the noninvasive technique for visualizing the heart. In this article, backgrounds and present situation of coronary angiography using synchrotron radiation are reviewed. Firstly, visual imaging techniques of the cardiovascular system are discussed in terms of angiography and digital subtraction angiography (DSA). Conventional temporal, energy, and hybrid subtraction modes used in DSA are referred to. Secondly, the application of synchrotron radiation is presented, focusing on the property of synchrotron radiation and K-edge subtraction angiography. Two kinds of synchrotron radiation beam methods are outlined. Interpretation of image data and various subtraction procedures remain unestablished. There is much to be done before coronary angiography using synchrotron radiation comes into a clinical practice. (N.K.)

  13. Analysis on the entrance surface dose and contrast medium dose at computed tomography and angiography in cardiovascular examination

    Energy Technology Data Exchange (ETDEWEB)

    Seo, Young Hyun [Dept. of Cardiovascular Center, Yeocheon Jeonnam Hospital, Yeosu (Korea, Republic of); Han, Jae Bok; Choi, Nam Gil; Song, Jong Nam [Dept. of Radiological Science, Dongshin University, Naju (Korea, Republic of)

    2016-12-15

    This study aimed to identify dose reduction measures by retrospectively analyzing the entrance surface dose at computed tomography and angiography in cardiovascular examination and to contribute the patients with renal impairmend and a high probability of side effects to determine the inspection's direction by measuring the contrast usages actually to active actions for the dose by actually measuring the contrast medium dose. The CTDIvol value and air kerma value, which are the entrance surface doses of the two examinations, and the contrast medium dose depending on the number of slides were compared and analyzed. This study was conducted in 21 subjects (11 males; 10 females) who underwent Cardiac Computed Tomographic Angiography (CCTA) and Coronary Angiography (CAG) in this hospital during the period from May 2014 to May 2016. The subject's age was 48-85 years old (mean 65±10 years old), and the weight was 37.6~83.3 kg (mean 63±6 kg). Dose reduction could be expected in the cardiovascular examination using CCTA rather than in the examination using CAG. In terms of contrast medium dose, CAG used a smaller dose than CCTA. In particular, as the number of slides increases at CAG, the contrast medium dose increases. Therefore, in order to reduce the contrast medium dose, the number of slides suitable for the scan range must be selected.

  14. Advances in radiological imaging of the renal arteries and veins

    International Nuclear Information System (INIS)

    Miao Xiaofan; Tang Lijun; Yang Bing

    2013-01-01

    Familiarity with the normal anatomy of the renal vessels and common variants is of particular importance for the operator who performs renal transplantation or therapeutic interventions in the renal vessels. Because of the recent major advances in multislice spiral computed tomography angiography (MSCTA) techniques, our ability has been considerably improved to determine the patterns and characters of renal arteries and veins. This article summarizes the research situation and progress in the area of renal vessel imaging anatomy. Some regularity in the distribution of renal vessel positions, dimensions and variations among patients who received MSCTA examinations, and these anatomical measurements are of great value for clinical diagnosis and treatment. (authors)

  15. Tratamento endovascular de aneurisma da artéria renal por embolização com micromolas preservando o fluxo sangüíneo renal: relato de caso Endovascular treatment of renal artery aneurysm using microcoil embolization and renal blood flow preservation: case report

    Directory of Open Access Journals (Sweden)

    Marco Aurélio Cardozo

    2007-06-01

    Full Text Available O tratamento endovascular da doença aneurismática da artéria renal tem sido, cada vez mais, aceito como uma alternativa à cirurgia convencional, especialmente em casos de aneurismas complexos intra-parenquimatosos ou que comprometam a bifurcação da artéria renal. Os autores relatam a experiência do tratamento endovascular de uma paciente com aneurisma sacular da bifurcação da artéria renal direita, associado à hipertensão renovascular de difícil controle. Foi realizada a cateterização seletiva da artéria renal, com a inserção de micromolas no saco aneurismático. O aneurisma foi completamente ocluído com preservação total do fluxo sanguíneo renal. A evolução clínica foi satisfatória com redução significativa das medicações anti-hipertensivas. A angio-tomografia de controle, após o oitavo mês do procedimento, confirmou o sucesso do tratamento.Endovascular treatment of renal artery aneurysmal disease has been increasingly accepted as an alternative to conventional surgery, especially in cases of renal artery bifurcation or complex intrarenal aneurysms. The authors report a case of endovascular treatment of a saccular aneurysm of the right renal artery bifurcation associated with poorly controlled renovascular hypertension. Selective catheterization of the renal artery was performed and microcoils were inserted into the aneurysmal sac. The aneurysm was completely obliterated with total preservation of renal blood flow. Clinical evolution was satisfactory with significant reduction in anti-hypertensive drugs. Control tomographic angiography, after eight months, confirmed treatment success.

  16. Intra-arterial digital subtraction angiography (IA-DSA) with carbon dioxide

    International Nuclear Information System (INIS)

    Takeda, Toshiaki; Ido, Kunio; Yuasa, Yuji

    1988-01-01

    Intra-Arterial Digital Subtraction Angiography (IA-DSA) with Carbon Dioxide (CO 2 ) was performed on 41 patients mainly with liver or renal diseases, and its angiographic manifestation was compared with that of conventional angiography. Although the image quality of the arterial or capillary phase was inferior to that of conventional angiography with iodinated contrast media, the detectablity of arterio-venous shunting was excellent. In fact, DSA with CO 2 revealed the presence of A-V (A-P) shunt in 26 patients (26/41:63.4 % HCC, 13/15:86.7% metastatic liver tumor, 2/3:66.7 % RCC, 1/5:20 %). On the other hand, conventional angiography was able to show in only 5 cases. DSA with CO 2 will become an effective method for detecting minute arterio-venous shunting which can not be demonstrated with conventional angiography. (author)

  17. Significance of MR angiography in the diagnosis of aberrant renal arteries as the cause of ureteropelvic junction obstruction in children; Stellenwert der MR-Angiografie in der Diagnostik aberrierender Nierenarterien als Ursache einer Ureterabgangsstenose bei Kindern

    Energy Technology Data Exchange (ETDEWEB)

    Ritter, L.; Sorge, I.; Hirsch, F.W.; Vieweger, A. [Leipzig Univ. (Germany). Dept. of Pediatric Radiology; Goetz, G.; Lehnert, T.; Buehligen, U.; Geyer, C. [Leipzig Univ. (Germany). Dept. of Pediatric Surgery

    2015-01-15

    To determine the importance of MRI with contrast-enhanced MRA for the detection or exclusion of aberrant or obstructing renal arteries in ureteropelvic junction obstruction in children. Key word-based search in RIS database (ureteropelvic junction obstruction/MRI) and retrospective comparison of arterial findings from preoperative contrast-enhanced MRA and intra-operative inspection. From 2007 to 2013, 19 children with ureteropelvic junction obstruction underwent contrast-enhanced MRA. Based on the results of the MRI scan and MAG3 scintigraphy, the children were referred to surgery (Anderson-Hynes-pyeloplasty). An aberrant renal artery was diagnosed with MRI in 14 of 19 children, and intra-operative inspection confirmed 13 of those 14. In the remaining 5 children, no aberrant vessel could be observed in MRI and this was confirmed intra-operatively in 3 of the 5 cases, while in the remaining 2, an aberrant vessel was found. Of the 14 children with aberrant vessels, 12 underwent surgery due to assumed ureteral obstruction, which was confirmed by surgery in 11 cases. In one case, an aberrant artery was found intra-operatively, but obstruction could not be confirmed. In one of the 14 children, the vessel was found in MRI, but its obstructing character was negated via MRA, which was confirmed intra-operatively. In the diagnosis of aberrant and obstructing renal arteries, contrast-enhanced MRA presents 85 % sensitivity and 80 % specificity, with a positive predictive value of 0.8. MRI with contrast-enhanced MRA is suitable to detect aberrant and obstructing renal arteries. An obstructive effect of the aberrant vessel is to be assumed if the vessel has a close relationship to the ureteropelvic junction and if it is linearly stretched.

  18. Multiple intracranial aneurysms in polyarteritis nodosa: MRI and angiography

    International Nuclear Information System (INIS)

    Oran, I.; Memis, A.; Parildar, M.; Yunten, N.

    1999-01-01

    In polyarteritis nodosa involvement of the central nervous system is infrequent; small cerebral infarcts are the most common neuroradiological finding. We report a 10-year-old boy with polyarteritis nodosa and intracranial haemorrhage. MRI showed an intracerebral haemorrhage. Angiography revealed two peripheral aneurysms in the posterior cerebral circulation, previously reported on only two occasions, and multiple microaneurysms in the hepatic, renal, mesenteric and even the lumbar arteries. (orig.)

  19. Age-related change in renal corticomedullary differentiation: evaluation with noncontrast-enhanced steady-state free precession (SSFP) MRI with spatially selective inversion pulse using variable inversion time.

    Science.gov (United States)

    Noda, Yasufumi; Kanki, Akihiko; Yamamoto, Akira; Higashi, Hiroki; Tanimoto, Daigo; Sato, Tomohiro; Higaki, Atsushi; Tamada, Tsutomu; Ito, Katsuyoshi

    2014-07-01

    To evaluate age-related change in renal corticomedullary differentiation and renal cortical thickness by means of noncontrast-enhanced steady-state free precession (SSFP) magnetic resonance imaging (MRI) with spatially selective inversion recovery (IR) pulse. The Institutional Review Board of our hospital approved this retrospective study and patient informed consent was waived. This study included 48 patients without renal diseases who underwent noncontrast-enhanced SSFP MRI with spatially selective IR pulse using variable inversion times (TIs) (700-1500 msec). The signal intensity of renal cortex and medulla were measured to calculate renal corticomedullary contrast ratio. Additionally, renal cortical thickness was measured. The renal corticomedullary junction was clearly depicted in all patients. The mean cortical thickness was 3.9 ± 0.83 mm. The mean corticomedullary contrast ratio was 4.7 ± 1.4. There was a negative correlation between optimal TI for the best visualization of renal corticomedullary differentiation and age (r = -0.378; P = 0.001). However, there was no significant correlation between renal corticomedullary contrast ratio and age (r = 0.187; P = 0.20). Similarly, no significant correlation was observed between renal cortical thickness and age (r = 0.054; P = 0.712). In the normal kidney, noncontrast-enhanced SSFP MRI with spatially selective IR pulse can be used to assess renal corticomedullary differentiation and cortical thickness without the influence of aging, although optimal TI values for the best visualization of renal corticomedullary junction were shortened with aging. © 2013 Wiley Periodicals, Inc.

  20. CT and MR angiography

    International Nuclear Information System (INIS)

    Bert, A.L.; Marshal, G.

    1995-01-01

    CT-angiography is a new vessel imaging technique based on the volumetric scanning of the region of interst during the first pass of IV bolus injection of contrast medium. MR-angiography is a titally noninvasive technique. The differentiation of flowing blood from the adjecent stationary tissues is based on the detection of blood motion. The flowing blood is highlighted with white light. CT- and MR-angiographic techniques are used to establish% stenoses and occlusions in intracranial arteries; aneurisms; trombosis of intracranial veins and venous angioma; diseases of neck vessels, thoracic vessels, abdominal vessels. Blood flow direction in cirrotic patients with portal hypertension can be determined in the portal vein, as well as the presence of thrombosis

  1. Development of serial magnification angiography and its clinical significance

    International Nuclear Information System (INIS)

    Sasaki, Tsuneo; Matsubara, Kazuhito; Ishiguchi, Tsuneo; Mashita, Shinichi; Kaii, Osamu

    1979-01-01

    In order to apply serial magnification angiography to clinical examinations so easily, a serial cardioangiography apparatus was equipped with a tube having 0.1 mm focal spot and with DRX-431HD diode. A CAT-FK Type catheter bed (Toshiba) was used as a roentgenographic table and a PUCK film changer was used. Thus, serial magnification angiography can be easily used to clinical examinations, and can be set in a usual x-ray photographic studio. Serial magnification angiography was used to examine the cerebral vessels in 6 patients, vessels of the pulmonary circulation in 1 patient, bronchial arteries in 6 patients, the celiac artery in 18 patients, the superior mesenteric artery in 2 patients, inferior mesenteric artery in 2 patients, the renal artery in 2 patients, and the adrenal vein in 7 patients. Owing to this angiography, minute changes in the vessel in the lesion can be observed and fine neovascularity can be detected. Thus, serial magnification angiography makes diagnoses of vascular disorders easier. (Ichikawa, K.)

  2. Donor evaluation of extended time 99mTcDTPA renal scintigraphy for added information to guide donor kidney selection: a technologist perspective

    International Nuclear Information System (INIS)

    Kale, Chanchala; Tarsaria, Sunita; Jaiswal, R.; Amrita; Roshni; Pallavi

    2010-01-01

    Full text: 99m Tc-DTPA renal scan exposes the patient to considerably less radiation and the images are of superior quality. In donor patients a short time renal scintigraphy to calculate GFR by gates formula is widely accepted in clinical practice. Apart from kidney GFR, renal scan gives added information regarding size, shape and position of kidney, perfusion, peaking time, peak to T 1/2 ratio, transit time, perfusion, split function, assessment of drainage pattern. Aim: The purpose of this study was to evaluate significance of extended time 99m Tc DTPA renogram for appropriate selection of donor kidney. Materials and Method: A retrospective study on 66 patients (female-40, male-26, age range - 22-70 years, mean 48±24) was carried out in our centre. Patients were adequately hydrated before the study. Diuretic intervention renal dynamic scintigraphy (F+10) was performed after administering 5mCi of DTPA intravenously. Sequential dynamic images (Phase I-2 sec/frame for 1 min, Phase II-1 min/frame for 29 min) were acquired posteriorly on GE Millennium VG gamma camera. Pre and post syringe counts were also taken. Standard protocol was used for processing. Along with other parameters GFR by Gates formula was obtained Result: GFR was found to be in the range of 68.7 ml/min - 135.8 ml/min. (mean GFR = 102.25 ml/min). It was found that in 50 patients (75%) both Kidney GFR was normal. Whereas in 2 patients (3.0%) global GFR was low. There were 7 patients (10.60%) in which pelvicalceal hold up was seen which adequately cleared with lasix. One patient ( 99m Tc-DTPA renal scintigraphy with diuretic (F+10, 30 min study) as a functional modality is significantly useful in the selection of donor kidney

  3. Superselective pseudo-continuous arterial spin labeling angiography

    Energy Technology Data Exchange (ETDEWEB)

    Jensen-Kondering, Ulf [Department of Radiology and Neuroradiology, University Medical Center Schleswig-Holstein, Kiel (Germany); Lindner, Thomas, E-mail: thomas.lindner@uksh.de [Department of Radiology and Neuroradiology, University Medical Center Schleswig-Holstein, Kiel (Germany); Osch, Matthias J.P. van [C. J. Gorter Center for High Field MRI, Department of Radiology, Leiden University Medical Center, Leiden (Netherlands); Rohr, Axel; Jansen, Olav [Department of Radiology and Neuroradiology, University Medical Center Schleswig-Holstein, Kiel (Germany); Helle, Michael [Department of Radiology and Neuroradiology, University Medical Center Schleswig-Holstein, Kiel (Germany); Now with Philips GmbH Innovative Technologies, Research Laboratories, Hamburg (Germany)

    2015-09-15

    Highlights: • Superselective arterial spin labeling was capable of acquiring angiograms of individually selected arteries. • Image quality was similar compared with a routinely used time-of-flight angiography. • Superselective arterial spin labeling was utilized in patients with arterio-venous malformations and made it possible to visualize individual feeding vessels in a complete non-invasive way - Abstract: Purpose: To evaluate the utility of a novel non-contrast enhanced, vessel-selective magnetic resonance angiography (MRA) approach based on superselective pseudo-continuous arterial spin labeling (ASL) for the morphologic assessment of intracranial arteries when compared to a clinically used time-of-flight (TOF) MRA. Materials and methods: Three sets of selective ASL angiographies (right and left internal carotid artery, basilar artery) as well as one TOF data set were obtained from each of the five volunteers included in this study on a clinical 1.5T system. The depiction of arterial segments as well as their delineation was evaluated and independently analyzed by two radiologists. Additionally, the ASL angiography approach was performed in two patients suffering from arterio-venous malformations (AVM) in order to illustrate potential applications in a clinical setting. Results: In both angiography techniques, intracranial arteries and their segments (distal branches up to A5 segments of the anterior cerebral arteries, M8 segments of the middle cerebral arteries, and P5 segments of the posterior cerebral arteries) were continuously depicted with excellent inter-reader agreement (κ > 0.81). In AVM patients, reconstructed images of the TOF angiography presented similar information about the size and shape of the AVM as did superselective ASL angiography. In addition, the acquired ASL angiograms of selected vessels allowed assessing the blood supply of individually labeled arteries to the AVM which could also be confirmed by digital subtraction angiography

  4. Superselective pseudo-continuous arterial spin labeling angiography

    International Nuclear Information System (INIS)

    Jensen-Kondering, Ulf; Lindner, Thomas; Osch, Matthias J.P. van; Rohr, Axel; Jansen, Olav; Helle, Michael

    2015-01-01

    Highlights: • Superselective arterial spin labeling was capable of acquiring angiograms of individually selected arteries. • Image quality was similar compared with a routinely used time-of-flight angiography. • Superselective arterial spin labeling was utilized in patients with arterio-venous malformations and made it possible to visualize individual feeding vessels in a complete non-invasive way - Abstract: Purpose: To evaluate the utility of a novel non-contrast enhanced, vessel-selective magnetic resonance angiography (MRA) approach based on superselective pseudo-continuous arterial spin labeling (ASL) for the morphologic assessment of intracranial arteries when compared to a clinically used time-of-flight (TOF) MRA. Materials and methods: Three sets of selective ASL angiographies (right and left internal carotid artery, basilar artery) as well as one TOF data set were obtained from each of the five volunteers included in this study on a clinical 1.5T system. The depiction of arterial segments as well as their delineation was evaluated and independently analyzed by two radiologists. Additionally, the ASL angiography approach was performed in two patients suffering from arterio-venous malformations (AVM) in order to illustrate potential applications in a clinical setting. Results: In both angiography techniques, intracranial arteries and their segments (distal branches up to A5 segments of the anterior cerebral arteries, M8 segments of the middle cerebral arteries, and P5 segments of the posterior cerebral arteries) were continuously depicted with excellent inter-reader agreement (κ > 0.81). In AVM patients, reconstructed images of the TOF angiography presented similar information about the size and shape of the AVM as did superselective ASL angiography. In addition, the acquired ASL angiograms of selected vessels allowed assessing the blood supply of individually labeled arteries to the AVM which could also be confirmed by digital subtraction angiography

  5. Imaging of renal metastases

    International Nuclear Information System (INIS)

    Bruneton, J.N.; Normand, F.; Balu-Maestro, C.; Rogopoulos, A.; Drouillard, J.; Laurent, F.

    1988-01-01

    Metastases are the most frequent malignant tumors of the kidney, but these lesions are of late onset in neoplastic disease. The 19 cases reported here were all investigated with various imaging techniques (CT 12 cases, ultrasonography 12 cases, urography 8 cases, angiography 2 cases, MRI 1 case). The most common primary malignancies were lung cancer, melanoma and cancer of the controlateral kidney. In this series, 8 of the lesions were solitary, and 9 were unilateral. Tumor vascularity was evaluated in 15 cases: 14 of these lesions were hypovascular. The differential diagnosis includes small cysts, lymphoma, bilateral renal cancer, multiple small abscesses and multiple small infarcts [fr

  6. Angiography cisternography phlebography linphography

    International Nuclear Information System (INIS)

    Lago, Graciela.

    1994-01-01

    As the title says the four diagnostic techniques are described, indication, radiopharmaceutical, administration,first pass imaging and perfusion protocols in gamma cammera, results expected for normal subjects and an example of renal perfusion with kidney serialscintigraphy

  7. Early detection and intervention using neutrophil gelatinase-associated lipocalin (NGAL) may improve renal outcome of acute contrast media induced nephropathy: a randomized controlled trial in patients undergoing intra-arterial angiography (ANTI-CIN Study).

    Science.gov (United States)

    Schilcher, Gernot; Ribitsch, Werner; Otto, Ronald; Portugaller, Rupert H; Quehenberger, Franz; Truschnig-Wilders, Martini; Zweiker, Robert; Stiegler, Philipp; Brodmann, Marianne; Weinhandl, Klemens; Horina, Joerg H

    2011-08-17

    Patients with pre-existing impaired renal function are prone to develop acute contrast media induced nephropathy (CIN). Neutrophil gelatinase-associated lipocalin (NGAL), a new biomarker predictive for acute kidney injury (AKI), has been shown to be useful for earlier diagnosis of CIN; however, urinary NGAL values may be markedly increased in chronic renal failure at baseline. Results from those studies suggested that urinary NGAL values may not be helpful for the clinician. An intravenous volume load is a widely accepted prophylactic measure and possibly a reasonable intervention to prevent deterioration of renal function. The aim of our study is to evaluate NGAL as an early predictor of CIN and to investigate the clinical benefit of early post-procedural i.v. hydration. The study will follow a prospective, open-label, randomized controlled design. Patients requiring intra-arterial contrast media (CM) application will be included and receive standardized, weight-based, intravenous hydration before investigation. Subjects with markedly increased urinary NGAL values after CM application will be randomized into one of two study groups. Group A will receive 3-4 ml/kg BW/h 0.9% saline intravenously for 6 hours. Group B will undergo only standard treatment consisting of unrestricted oral fluid intake. The primary outcome measure will be CIN defined by an increase greater than 25% of baseline serum creatinine. Secondary outcomes will include urinary NGAL values, cystatin C values, contrast media associated changes in cardiac parameters such as NT-pro-BNP/troponin T, changes in urinary cytology, need for renal replacement treatment, length of stay in hospital and death.We assume that 20% of the included patients will show a definite rise in urinary NGAL. Prospective statistical power calculations indicate that the study will have 80% statistical power to detect a clinically significant decrease of CIN of 40% in the treatment arm if 1200 patients are recruited into the

  8. Angiography and the gastrointestinal bleeder

    International Nuclear Information System (INIS)

    Baum, S.

    1982-01-01

    The role of angiography in the diagnosis and treatment of gastrointestinal hemorrhage is discussed. Three categories of gastrointestinal bleeding are considered: upper gastrointestinal bleeding due to gastroesophageal varices, upper gastrointestinal bleeding of arterial or capillary origin, and lower gastrointestinal bleeding. The advantages and disadvantages of angiography are compared with those of radionuclide scanning and endoscopy or colonoscopy. It is anticipated that, as radionuclide scans are more widely employed, angiography will eventually be performed only in those patients with positive scans

  9. Digital subtraction angiography and intraarterial contrast medium injection for coronary examinations

    Energy Technology Data Exchange (ETDEWEB)

    Tobio, R; Kallmeyer, C; Castello, J

    1985-01-01

    Digital subtraction angiography (DSA) is an established method of vasography, most extensively used as i.v. DSA. Intraarterial injection, however, applying selective or non-selective contrast medium injection, seems to be at least as important a technique although it has not yet met with corresponding interest. The article explains advantages of the technique for angiographic examinations, in particular of coronary angiography.

  10. Evaluation of a liquid embolization agent (Onyx) for transcatheter embolization for renal vascular lesions

    Energy Technology Data Exchange (ETDEWEB)

    Rennert, Janine; Herold, T.; Schreyer, A.G.; Jung, E.M.; Mueller-Wille, R.; Zorger, N. [Inst. fuer Roentgendiagnostik, Klinikum der Univ. Regensburg (Germany); Banas, B.; Feuerbach, S. [Medizinische Klinik, Nephrologie, Univ. Regensburg (Germany); Lenhart, M. [Klinik fuer Diagnostische und Interventionelle Radiologie, Sozialstiftung Bamberg (Germany)

    2009-10-15

    Purpose: to evaluate the therapeutic outcome after endovascular treatment of renal vascular lesions using the liquid embolization agent, Onyx. Materials and methods: between 2004 and 2008 nine patients with renal vascular lesions were treated with transcatheter arterial embolization using Onyx. The renal vascular lesions consisted of 4 AV-fistulas, a pseudoaneurysm, bleeding from a single subsegmental artery, diffuse parenchymal bleeding after trauma, septic embolizations and multiple aneurysms in endocarditis. All patients underwent selective angiography of the renal artery. A dimethyl sulfoxide (DMSO)-compatible microcatheter was used and Onyx was injected. The technical and clinical success rate, examination time and procedure-related complications were documented. Results: the overall technical and clinical success rate was 100%. One patient had to be treated twice due to recurrent bleeding after an accidental puncture with a drainage catheter. No loss of viable renal tissue occurred in 4 cases. In 4 patients mild to moderate parenchyma loss was noted. In one patient having diffuse renal bleeding, occlusion of the main renal artery was performed. No procedure-related complications were noted. The mean examination time was 16.17 min when treating with Onyx alone and 60 min when using a combination of Onyx and coils. Within an average follow-up period of 21 months, no recurrent renal bleeding or recurrent AV-fistulas occurred. Conclusion: Onyx is an effective embolization agent for the treatment of renal vascular lesions. It allows controlled and quick application with low complication rates and a short examination time as a standalone agent or in combination with coils. (orig.)

  11. Clinical aspects of dynamic renal imaging with radiochlormerodrin, /sup 99m/Tc pertechnetate, and 131I orthoiodohippurate

    International Nuclear Information System (INIS)

    Freeman, L.M.

    1972-01-01

    Three major radionuclide imaging studies are available for assistance in the diagnostic evaluation of renal disorders. Morphology and functional tubular mass may be depicted with mercury-197 chlormerodrin or one of the new technetium-99m renal imaging agents (iron ascorbate or chelate). Excretion data as well as visualization in severely diseased kidneys are obtained with iodine-131 ortho-iodohippurate (hippuran). Vascular patterns of the kidney and lesions within it are obtained using a small volume, high activity bolus of a short-lived radiopharmaceutical, such as technetium-99m pertechnetate. These procedures are to be complementary and not competitive with radiographic studies such as urography, nephrotomography, and selective renal angiography. Each clinical situation must be evaluated individually so that the optimal study or combination of studies is utilized to help supply whatever information is sought. Familiarity with the available imaging techniques and their limitations will help one approach such situations more intelligently. (U.S.)

  12. Intraarterial digital subtraction angiography

    International Nuclear Information System (INIS)

    Davis, P.C.

    1987-01-01

    Digital subtraction angiography (DSA) refers to a radiographic technique of amplifying low levels of contrast from intravascular iodine into an acceptable image of vascular anatomy. Initial enthusiasm suggested that DSA using intravenous injections (IV-DSA) would eliminate most conventional film-screen angiographic studies. It was soon apparent, however, that IV-DSA examinations were often compromised in those patients who most needed a less invasive study. Indeed, only a 70 to 85 percent accuracy rate was achieved with IV-DSA, primarily due to motion artifact, poor cardiac output, overlap of pertinent vessels, and inability to resolve smaller vessels

  13. Nonenhanced MR angiography techniques

    International Nuclear Information System (INIS)

    Lanzman, R.S.; Kroepil, P.; Blondin, D.; Schmitt, P.

    2011-01-01

    Especially in regard to the potential risks for the development of nephrogenic systemic fibrosis (NSF) following the administration of Gadolinium-based contrast material, nonenhanced MR angiography (MRA) methods are becoming ever more important. Besides well-established time-of-flight (TOF) and phase-contrast (PC) MRA, alternative imaging techniques based on balanced steady-state free precession (bSSFP) and turbo-spin-echo (TSE) sequences are increasingly used in combination with or without arterial spin labeling (ASL) strategies. This article provides an overview of the principles and clinical values of different nonenhanced MRA techniques. In addition, recent nonenhanced MRA developments are presented. (orig.)

  14. Attenuation-based kV pair selection in dual source dual energy computed tomography angiography of the chest: impact on radiation dose and image quality

    Energy Technology Data Exchange (ETDEWEB)

    Renapurkar, Rahul D.; Azok, Joseph; Lempel, Jason; Karim, Wadih; Graham, Ruffin [Thoracic Imaging, L10, Imaging Institute, Cleveland Clinic, Cleveland, OH (United States); Primak, Andrew [Siemens Medical Solutions, Malvern, PA (United States); Tandon, Yasmeen [Case Western Reserve University-Metro Health Medical Center, Department of Radiology, Cleveland, OH (United States); Bullen, Jennifer [Quantitative Health Sciences, Cleveland Clinic, Cleveland, OH (United States); Dong, Frank [Section of Medical Physics, Cleveland Clinic, Cleveland, OH (United States)

    2017-08-15

    The purpose of this study was to evaluate the impact of attenuation-based kilovoltage (kV) pair selection in dual source dual energy (DSDE)-pulmonary embolism (PE) protocol examinations on radiation dose savings and image quality. A prospective study was carried out on 118 patients with suspected PE. In patients in whom attenuation-based kV pair selection selected the 80/140Sn kV pair, the pre-scan 100/140Sn CTDIvol (computed tomography dose index volume) values were compared with the pre-scan 80/140Sn CTDIvol values. Subjective and objective image quality parameters were assessed. Attenuation-based kV pair selection switched to the 80/140Sn kV pair (''switched'' cohort) in 63 out of 118 patients (53%). The mean 100/140Sn pre-scan CTDIvol was 8.8 mGy, while the mean 80/140Sn pre-scan CTDIvol was 7.5 mGy. The average estimated dose reduction for the ''switched'' cohort was 1.3 mGy (95% CI 1.2, 1.4; p < 0.001), representing a 15% reduction in dose. After adjusting for patient weight, mean attenuation was significantly higher in the ''switched'' vs. ''non-switched'' cohorts in all five pulmonary arteries and in all lobes on iodine maps. This study demonstrates that attenuation-based kV pair selection in DSDE examination is feasible and can offer radiation dose reduction without compromising image quality. (orig.)

  15. [Aortic dissection spread to the renal arteries: role of renal volumetry after angioplasty].

    Science.gov (United States)

    Vautrin, E; Thony, F; Chavanon, O; Hannachi, I; Barone-Rochette, G; Pierre, H; Baguet, J-P

    2012-06-01

    Type A or B aortic dissection can extend to renal arteries, causing a renal ischemia which treatment is usually endovascular. The aim of our study is to show the interest of the renal volumetry in the follow-up of these patients. Twenty-two patients (16 men, mean age 63.4±11.8years, BMI 25.2±3.4kg/m(2)) with a type A or B aortic dissection spread to one or to both renal arteries and followed at Grenoble university hospital were consecutively included. All patients underwent renal angiography with aorto-renal pressure gradients measurements and follow-up by renal volumetry (scanner Siemens(®)). A renal ischemia was defined by a decrease of 20% or more of the volumetry. Sixteen patients (73%) were hypertensive before the aortic dissection among which ten (62%) were treated. Eight patients (36%) have a significant renal pressure gradient among which five (62%) underwent renal endovascular therapy. The renal volumetry of these five patients remained unchanged while six of 17 patients (36%) without angioplasty have a decreasing volumetry. Renal volumetry appeared an effective and attractive option for the follow-up of the patients with aortic dissection spread to the renal arteries. These results should be taken into account to put the indication of an endovascular treatment. Copyright © 2012 Elsevier Masson SAS. All rights reserved.

  16. Renal denervation

    DEFF Research Database (Denmark)

    Olsen, Lene Kjær; Kamper, Anne-Lise; Svendsen, Jesper Hastrup

    2015-01-01

    PURPOSE OF REVIEW: Renal denervation (RDN) has, within recent years, been suggested as a novel treatment option for patients with resistant hypertension. This review summarizes the current knowledge on this procedure as well as limitations and questions that remain to be answered. RECENT FINDINGS...... selection, anatomical and physiological effects of RDN as well as possible beneficial effects on other diseases with increased sympathetic activity. The long awaited Symplicity HTN-3 (2014) results illustrated that the RDN group and the sham-group had similar reductions in BP. SUMMARY: Initial studies...

  17. Measuring the quality of renal care: things to keep in mind when selecting and using quality indicators

    NARCIS (Netherlands)

    van der Veer, Sabine N.; van Biesen, Wim; Couchoud, Cécile; Tomson, Charles R. V.; Jager, Kitty J.

    2014-01-01

    This educational paper discusses a variety of indicators that can be used to measure the quality of care in renal medicine. Based on what aspect of care they reflect, indicators can be grouped into four main categories: structure, process, surrogate outcome and outcome indicators. Each category has

  18. Is body weight the most appropriate criterion to select patients eligible for low-dose pulmonary CT angiography? Analysis of objective and subjective image quality at 80 kVp in 100 patients

    Energy Technology Data Exchange (ETDEWEB)

    Szucs-Farkas, Zsolt; Strautz, Tamara; Patak, Michael A.; Kurmann, Luzia; Vock, Peter; Schindera, Sebastian T. [University Hospital and University of Berne, Department of Diagnostic, Interventional and Paediatric Radiology, Berne (Switzerland)

    2009-08-15

    The objective of this retrospective study was to assess image quality with pulmonary CT angiography (CTA) using 80 kVp and to find anthropomorphic parameters other than body weight (BW) to serve as selection criteria for low-dose CTA. Attenuation in the pulmonary arteries, anteroposterior and lateral diameters, cross-sectional area and soft-tissue thickness of the chest were measured in 100 consecutive patients weighing less than 100 kg with 80 kVp pulmonary CTA. Body surface area (BSA) and contrast-to-noise ratios (CNR) were calculated. Three radiologists analyzed arterial enhancement, noise, and image quality. Image parameters between patients grouped by BW (group 1: 0-50 kg; groups 2-6: 51-100 kg, decadelly increasing) were compared. CNR was higher in patients weighing less than 60 kg than in the BW groups 71-99 kg (P between 0.025 and <0.001). Subjective ranking of enhancement (P=0.165-0.605), noise (P=0.063), and image quality (P=0.079) did not differ significantly across all patient groups. CNR correlated moderately strongly with weight (R=-0.585), BSA (R=-0.582), cross-sectional area (R=-0.544), and anteroposterior diameter of the chest (R=-0.457; P<0.001 all parameters). We conclude that 80 kVp pulmonary CTA permits diagnostic image quality in patients weighing up to 100 kg. Body weight is a suitable criterion to select patients for low-dose pulmonary CTA. (orig.)

  19. Diagnostic accuracy of multi-slice computed tomographic angiography in the detection of cerebral aneurysms

    International Nuclear Information System (INIS)

    Haghighatkhah, H. R.; Sabouri, S.; Borzouyeh, F.; Bagherzadeh, M. H.; Bakhshandeh, H.; Jalali, A. H.

    2008-01-01

    Multislice computed tomographic angiography is a rapid and minimally invasive method for the detection of intracranial aneurysms. The purpose of this study was to compare Multislice computed tomographic angiography with digital subtraction angiography In the diagnosis of cerebral aneurysms. Patients and Methods: In this cross sectional study we evaluated 111 consecutive patients [42(37.8%) male and 69(62.2%) female], who were admitted under clinical symptoms and signs. suggestive of harboring an intracranial aneurysm by using a four detector Multislice computed tomographic angiography. Then we compared results of Multislice computed tomographic angiography with digital subtraction angiography results as a gold standard method. Digital subtraction angiography was performed by bilateral selective common carotid artery injections and either unilateral or bilateral vertebral artery injections, as necessary. Multislice computed tomographic angiography images were interpreted by one radiologist and digital subtraction angiography was performed by another radiologist who was blinded to the interpretation of the Multislice computed tomographic angiograms. Results: The mean ±S D age of the patients was 49.1±13.6 years (range: 12-84 years). We performed Multislice computed tomographic in 111 and digital subtraction angiography in 85 patients. The sensitivity, specificity, positive predictive value, negative predictive value, positive and negative likelihood ratio of Multislice computed tomographic angiography, when compared with digital subtraction angiography as the gold standard, were 100%, 90%, 87.5%, 100%, 10 and 0, respectively. Conclusion: Multislice computed tomographic angiography seems to be an accurate and noninvasive imaging modality in the diagnosis of intracranial aneurysms

  20. Preoperative CT-Angiography Predicts Ex Vivo Vein Length for Right Kidneys After Laparoscopic Donor Nephrectomy

    NARCIS (Netherlands)

    Özdemir-van Brunschot, D.M.D.; Rottier, S.J.; Ouden, J.E. den; Jagt, M.F.P. van der; D'Ancona, F.C.H.; Kloke, H.J.; Vliet, D. van der; Schultze Kool, L.J.; Warle, M.C.

    2015-01-01

    BACKGROUND Implantation of a kidney with a short renal vein is technically more challenging and therefore prone for technique-related complications. It remains unclear whether pre-operative computed tomography angiography (CTA), to assess vascular anatomy of the donor kidney, can be used to predict

  1. Evaluation of angiography performed by radiographers and nurses

    Energy Technology Data Exchange (ETDEWEB)

    Chalmers, N.; Conway, B.; Andrew, H.; Parkinson, A.; Butterfield, J.S.; Fawcitt, R. A

    2002-04-01

    AIM: To evaluate out-patient angiography performed by nurses and radiographers. MATERIALS AND METHODS: A protocol for out-patient angiography performed by nurses and radiographers was drawn up and approved by the Trust's Risk Management Committee. Following training, two experienced radiographers and one nurse undertook elective peripheral or renal angiography according to the protocol on 187 patients. Angiograms were performed using a 3F catheter introduced into the abdominal aorta from a femoral approach. Patients were discharged after 2 hours and contacted by telephone the following morning. RESULTS: No patient refused consent for the procedure. One hundred and seventy-two patients underwent successful catheterization without assistance from a radiologist. Radiologist assistance was required with femoral puncture or catheter/guidewire manipulation in 15 cases (8%). Images were considered diagnostic by the reporting radiologist in all but one case. This patient was recalled for further aortogram and pressure measurements. There was a single puncture site complication due to transient stenosis of the common femoral artery at the puncture site. This is thought to have been the result of subintimal injection of local anaesthetic, and it resolved spontaneously over 30 minutes. There were no delayed complications. CONCLUSION: Experienced nurses and radiographers can rapidly acquire the skills to perform diagnostic angiography safely and efficiently. Chalmers, N. et al. (2002)

  2. Mono-energy coronary angiography with a compact light source

    Science.gov (United States)

    Eggl, Elena; Mechlem, Korbinian; Braig, Eva; Kulpe, Stephanie; Dierolf, Martin; Günther, Benedikt; Achterhold, Klaus; Herzen, Julia; Gleich, Bernhard; Rummeny, Ernst; Noël, Peter B.; Pfeiffer, Franz; Muenzel, Daniela

    2017-03-01

    While conventional x-ray tube sources reliably provide high-power x-ray beams for everyday clinical practice, the broad spectra that are inherent to these sources compromise the diagnostic image quality. For a monochromatic x-ray source on the other hand, the x-ray energy can be adjusted to optimal conditions with respect to contrast and dose. However, large-scale synchrotron sources impose high spatial and financial demands, making them unsuitable for clinical practice. During the last decades, research has brought up compact synchrotron sources based on inverse Compton scattering, which deliver a highly brilliant, quasi-monochromatic, tunable x-ray beam, yet fitting into a standard laboratory. One application that could benefit from the invention of these sources in clinical practice is coronary angiography. Being an important and frequently applied diagnostic tool, a high number of complications in angiography, such as renal failure, allergic reaction, or hyperthyroidism, are caused by the large amount of iodine-based contrast agent that is required for achieving sufficient image contrast. Here we demonstrate monochromatic angiography of a porcine heart acquired at the MuCLS, the first compact synchrotron source. By means of a simulation, the CNR in a coronary angiography image achieved with the quasi-mono-energetic MuCLS spectrum is analyzed and compared to a conventional x-ray-tube spectrum. The results imply that the improved CNR achieved with a quasi-monochromatic spectrum can allow for a significant reduction of iodine contrast material.

  3. Evaluation of angiography performed by radiographers and nurses

    International Nuclear Information System (INIS)

    Chalmers, N.; Conway, B.; Andrew, H.; Parkinson, A.; Butterfield, J.S.; Fawcitt, R. A.

    2002-01-01

    AIM: To evaluate out-patient angiography performed by nurses and radiographers. MATERIALS AND METHODS: A protocol for out-patient angiography performed by nurses and radiographers was drawn up and approved by the Trust's Risk Management Committee. Following training, two experienced radiographers and one nurse undertook elective peripheral or renal angiography according to the protocol on 187 patients. Angiograms were performed using a 3F catheter introduced into the abdominal aorta from a femoral approach. Patients were discharged after 2 hours and contacted by telephone the following morning. RESULTS: No patient refused consent for the procedure. One hundred and seventy-two patients underwent successful catheterization without assistance from a radiologist. Radiologist assistance was required with femoral puncture or catheter/guidewire manipulation in 15 cases (8%). Images were considered diagnostic by the reporting radiologist in all but one case. This patient was recalled for further aortogram and pressure measurements. There was a single puncture site complication due to transient stenosis of the common femoral artery at the puncture site. This is thought to have been the result of subintimal injection of local anaesthetic, and it resolved spontaneously over 30 minutes. There were no delayed complications. CONCLUSION: Experienced nurses and radiographers can rapidly acquire the skills to perform diagnostic angiography safely and efficiently. Chalmers, N. et al. (2002)

  4. Hepatic Artery Angiography and Embolization for Hemobilia Following Laparoscopic Cholecystectomy

    International Nuclear Information System (INIS)

    Nicholson, Tony; Travis, Simon; Ettles, Duncan; Dyet, John; Sedman, Peter; Wedgewood, Kevin; Royston, Christopher

    1999-01-01

    Purpose: The effectiveness of angiography and embolization in diagnosis and treatment were assessed in a cohort of patients presenting with upper gastrointestinal hemorrhage secondary to hepatic artery pseudoaneurysm following laparoscopic cholecystectomy. Methods: Over a 6-year period 1513 laparoscopic cholecystectomies were carried out in our region. Nine of these patients (0.6%) developed significant upper gastrointestinal bleeding, 5-43 days after surgery. All underwent emergency celiac and selective right hepatic artery angiography. All were treated by coil embolization of the right hepatic artery proximal and distal to the bleeding point. Results: Pseudoaneurysms of the hepatic artery adjacent to cholecystectomy clips were demonstrated in all nine patients at selective right hepatic angiography. In three patients celiac axis angiography alone failed to demonstrate the pseudoaneurysm. Embolization controlled hemorrhage in all patients with no further bleeding and no further intervention. One patient developed a candidal liver abscess in the post-procedure period. All patients are alive and well at follow-up. Conclusion: Selective right hepatic angiography is vital in the diagnosis of upper gastrointestinal hemorrhage following laparoscopic cholecystectomy. Embolization offers the advantage of minimally invasive treatment in unstable patients, does not disrupt recent biliary reconstruction, allows distal as well as proximal control of the hepatic artery, and is an effective treatment for this potentially life-threatening complication

  5. Magnetic resonance angiography

    International Nuclear Information System (INIS)

    Kauczor, H.U.; Gamroth, A.H.; Schad, L.R.; Semmler, W.; Kaick, G. van; Tuengerthal, S.J.; Hausmann, R.

    1992-01-01

    MR angiography (MRA) proved to be promising combined to MR-Imaging (MRI) in the assessment of intrathoracic masses. Sequential FLASH 2D-angiograms were acquired in breathhold technique using the following parameters: TR=30 ms, TE=10 ms, FA=30deg. Section thickness was 5 mm with 1 mm overlap between sequential sections. Individual conditions of the examination were achieved by an automatised control procedure. Targeted MIP-postprocessing resulted in 3D-reconstructions illustrating vascular anatomy and avoiding superimposition. Presentation should be done by cine-mode for better spatial impression. This method was evaluated in a prospective study of 21 patients with malignant pulmonary and mediastinal masses in addition to spin-echo imaging. The diagnostic contribution concerning the relationship between the mass and the vasculature like displacement, stenosis, and poststenotic perfusion defect were assessed. (orig.) [de

  6. Digital subtraction angiography

    International Nuclear Information System (INIS)

    Neuwirth, J. Jr.; Bohutova, J.

    1987-01-01

    The quality of radiodiagnostic methods to a great extent depends on the quality of the resulting image. The basic technical principles are summed up of the different parts of digital subtraction angiography apparatus and of methods of improving the image. The instrument is based on a videochain consisting of an X-ray tube, an intensifier of the radiographic image, optical parts, a video camera, an analog-to-digital converter and a computer. The main advantage of the digitally processed image is the possibility of optimizing the image into a form which will contain the biggest amount of diagnostically valuable information. Described are the mathematical operations for improving the digital image: spatial filtration, pixel shift, time filtration, image integration, time interval differentation and matched filtering. (M.D.). 8 refs., 3 figs

  7. Carbon dioxide coronary angiography: A mechanical feasibility study with a cardiovascular simulator

    Directory of Open Access Journals (Sweden)

    Ivan Corazza

    2018-01-01

    Full Text Available The aim of this study was to carry out a bench evaluation of the biomechanical feasibility of carbon dioxide (CO2 coronary arteriography. Many patients among the aging population of individuals requiring cardiac intervention have underlying renal insufficiency making them susceptible to contrast-induced nephropathy. To include those patients, it is imperative to find an alternative and safe technique to perform coronary imaging on cardiac ischemic patients. As CO2 angiography has no renal toxicity, it may be a possible solution offering good imaging with negligible collateral effects. Theoretically, by carefully controlling the gas injection process, new automatic injectors may avoid gas reflux into the aorta and possible cerebral damage. A feasibility study is mandatory. A mechanical mock of the coronary circulation was developed and employed. CO2 was injected into the coronary ostium with 2 catheters (2F and 6F and optical images of bubbles flowing inside the vessels at different injection pressures were recorded. The gas behavior was then carefully studied for quantitative and qualitative analysis. Video recordings showed that CO2 injection at a precise pressure in the interval between the arterial dicrotic notch and the minimum diastolic value does not result in gas reflow into the aorta. Gas reflow was easier to control with the smaller catheter, but the gas bubbles were smaller with different vascular filling. Our simulation demonstrates that carefully selected injection parameters allow CO2 coronary imaging without any risk of gas reflux into the aorta.

  8. Carbon dioxide coronary angiography: A mechanical feasibility study with a cardiovascular simulator

    Science.gov (United States)

    Corazza, Ivan; Taglieri, Nevio; Pirazzini, Edoardo; Rossi, Pier Luca; Lombi, Alessandro; Scalise, Filippo; Caridi, James G.; Zannoli, Romano

    2018-01-01

    The aim of this study was to carry out a bench evaluation of the biomechanical feasibility of carbon dioxide (CO2) coronary arteriography. Many patients among the aging population of individuals requiring cardiac intervention have underlying renal insufficiency making them susceptible to contrast-induced nephropathy. To include those patients, it is imperative to find an alternative and safe technique to perform coronary imaging on cardiac ischemic patients. As CO2 angiography has no renal toxicity, it may be a possible solution offering good imaging with negligible collateral effects. Theoretically, by carefully controlling the gas injection process, new automatic injectors may avoid gas reflux into the aorta and possible cerebral damage. A feasibility study is mandatory. A mechanical mock of the coronary circulation was developed and employed. CO2 was injected into the coronary ostium with 2 catheters (2F and 6F) and optical images of bubbles flowing inside the vessels at different injection pressures were recorded. The gas behavior was then carefully studied for quantitative and qualitative analysis. Video recordings showed that CO2 injection at a precise pressure in the interval between the arterial dicrotic notch and the minimum diastolic value does not result in gas reflow into the aorta. Gas reflow was easier to control with the smaller catheter, but the gas bubbles were smaller with different vascular filling. Our simulation demonstrates that carefully selected injection parameters allow CO2 coronary imaging without any risk of gas reflux into the aorta.

  9. Serelaxin as a potential treatment for renal dysfunction in cirrhosis: Preclinical evaluation and results of a randomized phase 2 trial.

    Directory of Open Access Journals (Sweden)

    Victoria K Snowdon

    2017-02-01

    Full Text Available Chronic liver scarring from any cause leads to cirrhosis, portal hypertension, and a progressive decline in renal blood flow and renal function. Extreme renal vasoconstriction characterizes hepatorenal syndrome, a functional and potentially reversible form of acute kidney injury in patients with advanced cirrhosis, but current therapy with systemic vasoconstrictors is ineffective in a substantial proportion of patients and is limited by ischemic adverse events. Serelaxin (recombinant human relaxin-2 is a peptide molecule with anti-fibrotic and vasoprotective properties that binds to relaxin family peptide receptor-1 (RXFP1 and has been shown to increase renal perfusion in healthy human volunteers. We hypothesized that serelaxin could ameliorate renal vasoconstriction and renal dysfunction in patients with cirrhosis and portal hypertension.To establish preclinical proof of concept, we developed two independent rat models of cirrhosis that were characterized by progressive reduction in renal blood flow and glomerular filtration rate and showed evidence of renal endothelial dysfunction. We then set out to further explore and validate our hypothesis in a phase 2 randomized open-label parallel-group study in male and female patients with alcohol-related cirrhosis and portal hypertension. Forty patients were randomized 1:1 to treatment with serelaxin intravenous (i.v. infusion (for 60 min at 80 μg/kg/d and then 60 min at 30 μg/kg/d or terlipressin (single 2-mg i.v. bolus, and the regional hemodynamic effects were quantified by phase contrast magnetic resonance angiography at baseline and after 120 min. The primary endpoint was the change from baseline in total renal artery blood flow. Therapeutic targeting of renal vasoconstriction with serelaxin in the rat models increased kidney perfusion, oxygenation, and function through reduction in renal vascular resistance, reversal of endothelial dysfunction, and increased activation of the AKT

  10. A Renal Perforating Artery Mistaken for Arterial Bleeding after Percutaneous Renal Biopsy: A Case Report

    International Nuclear Information System (INIS)

    Kim, Ye Lim; Lee, Chang Hee; Kim, Kyeong Ah; Park, Cheol Min

    2009-01-01

    Perirenal hematoma after a renal biopsy is a common complication that usually resolves spontaneously, but this rarely requires transfusions or surgical/radiological intervention. We report here on a case of a renal perforating artery that was mistaken for renal arterial bleeding in a 53-year-old woman who was complicated with perirenal hematoma after undergoing a percutaneous renal biopsy. On the color and pulsed wave Doppler ultrasonography, linear blood flow was seen in the perirenal hematoma, which extended perpendicularly from the renal parenchyma into the perirenal space, and this linear blood flow exhibited an arterial pulse wave. On CT angiography, the renal perforating artery was demonstrated as a curvilinear vessel coursing tangentially to the renal margin and we decided that it was a pseudolesion caused by the renal perforating artery. A renal perforating artery may be mistaken for renal arterial bleeding after a percutaneous renal biopsy. A renal perforating artery and arterial bleeding can be differentiated by the location and shape seen on a color Doppler examination and the pulse waves characteristics

  11. A Renal Perforating Artery Mistaken for Arterial Bleeding after Percutaneous Renal Biopsy: A Case Report

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Ye Lim; Lee, Chang Hee; Kim, Kyeong Ah; Park, Cheol Min [Korea University College of Medicine, Seoul (Korea, Republic of)

    2009-12-15

    Perirenal hematoma after a renal biopsy is a common complication that usually resolves spontaneously, but this rarely requires transfusions or surgical/radiological intervention. We report here on a case of a renal perforating artery that was mistaken for renal arterial bleeding in a 53-year-old woman who was complicated with perirenal hematoma after undergoing a percutaneous renal biopsy. On the color and pulsed wave Doppler ultrasonography, linear blood flow was seen in the perirenal hematoma, which extended perpendicularly from the renal parenchyma into the perirenal space, and this linear blood flow exhibited an arterial pulse wave. On CT angiography, the renal perforating artery was demonstrated as a curvilinear vessel coursing tangentially to the renal margin and we decided that it was a pseudolesion caused by the renal perforating artery. A renal perforating artery may be mistaken for renal arterial bleeding after a percutaneous renal biopsy. A renal perforating artery and arterial bleeding can be differentiated by the location and shape seen on a color Doppler examination and the pulse waves characteristics

  12. Diagnosis of renal cell cancer by dynamic MRI

    International Nuclear Information System (INIS)

    Togami, Izumi; Kitagawa, Takahiro; Katoh, Katsuya

    1992-01-01

    Dynamic MRI was performed in 15 cases (16 lesions) of renal cell cancer. The enhanced pattern of the tumor was mainly evaluated and findings were compared with these of dynamic CT and renal angiography. Enhanced patterns on dynamic MRI and dynamic CT were similar, but each phase on dynamic MRI tended to be prolonged compared with dynamic CT. Many hypervascular tumors on renal angiography had prominent enhancement in an early phase on dynamic MRI, but there was no prominent enhancement in cases with tumor thrombi in the renal vein or IVC. All hypovascular tumors were enhanced to some degree without exception on dynamic MRI. Dynamic MRI is considered to be useful for the evaluation of the characterization, especially vascularity, of renal cell cancer, but we should pay attention to the differential diagnosis from other tumor in atypical cases because its enhanced patterns are various on dynamic MRI. (author)

  13. Transcatheter arterial embolization for congenital renal arteriovenous malformation

    International Nuclear Information System (INIS)

    Zhou Jun; Hu Tingyang; Yuan Jianhua; Yu Wenqiang

    2008-01-01

    Objective: To evaluate the effectiveness of transcatheter arterial embolization for congenital renal arteriovenous malformation. Methods: Seven cases of congenital renal arteriovenous malformation causing gross hematuria were retrospectively studied. All of 7 cases were demonstrated by means of angiography and then the catheter was placed superselectively into the involved arterial end of the malformation undertaking embolization with gelfoam, dehydrated ethanol, coils, etc. Results: All the malformations of the 7 cases were successfully embolized with stoppage of gross hematuria within 24 hours. No serious complications occurred except lumbago, fever, gastrointestinal reaction for one week. There was no recurrence of haematuria and the renal function was also normal in all cases during the follow-up for 36 to 98 months. Conclusions: Transcatheter renal arterial angiography and embolization are the important and effective management for the diagnosis and treatment of congenital renal arteriovenous malformation. (authors)

  14. Retrospective analysis of patients for development of nephrogenic systemic fibrosis following conventional angiography using gadolinium-based contrast agents.

    Science.gov (United States)

    Hoppe, Hanno; Spagnuolo, Sara; Froehlich, Johannes M; Nievergelt, Helga; Dinkel, Hans-Peter; Gretener, Silvia; Thoeny, Harriet C

    2010-03-01

    The purpose was to retrospectively review the data of 27 patients with renal insufficiency who underwent conventional angiography with gadolinium-based contrast agents (GDBCA) as alternative contrast agents and assess the occurrence of nephrogenic systemic fibrosis (NSF) together with associated potential risk factors. This HIPAA-compliant study had institutional review board approval, and informed consent was waived. Statistical analysis was performed for all available laboratory and clinical data, including dermatology reports. Type and amount of the GDBCA used were recorded for angiography and additional MRI studies, if applicable. Serum creatinine levels (SCr) pre- and post-angiography were recorded, and estimated glomerular filtration rates (eGFR) were calculated. Ten female and 17 male patients who underwent angiography with GDBCA were included. The mean amount of GDBCA administered was 44 +/- 15.5 ml (range 15-60 ml) or 0.24 + 0.12 mmol/kg (range 0.1-0.53 mmol/kg). At the time of angiography all patients had renal insufficiency (eGFR <60 ml/min/1.73 m(2)). Mean eGFR pre-angiography was 26 ml/min/1.73 m(2) and 33 ml/min/1.73 m(2) post-angiography. The mean follow-up period covers 28 months, range 1-84 months. Additional MRI studies with GDBCA administration were performed in 15 patients. One patient with typical skin lesions had developed biopsy-confirmed NSF. Conventional arterial angiography with GDBCA may play a role in the development of NSF in patients with renal insufficiency. Alternative contrast agents, such as CO(2) angiography or rather the use of low doses of iodinated contrast agents, should be considered in these patients.

  15. Retrospective analysis of patients for development of nephrogenic systemic fibrosis following conventional angiography using gadolinium-based contrast agents

    International Nuclear Information System (INIS)

    Hoppe, Hanno; Spagnuolo, Sara; Froehlich, Johannes M.; Thoeny, Harriet C.; Nievergelt, Helga; Dinkel, Hans-Peter; Gretener, Silvia

    2010-01-01

    The purpose was to retrospectively review the data of 27 patients with renal insufficiency who underwent conventional angiography with gadolinium-based contrast agents (GDBCA) as alternative contrast agents and assess the occurrence of nephrogenic systemic fibrosis (NSF) together with associated potential risk factors. This HIPAA-compliant study had institutional review board approval, and informed consent was waived. Statistical analysis was performed for all available laboratory and clinical data, including dermatology reports. Type and amount of the GDBCA used were recorded for angiography and additional MRI studies, if applicable. Serum creatinine levels (SCr) pre- and post-angiography were recorded, and estimated glomerular filtration rates (eGFR) were calculated. Ten female and 17 male patients who underwent angiography with GDBCA were included. The mean amount of GDBCA administered was 44 ± 15.5 ml (range 15-60 ml) or 0.24 + 0.12 mmol/kg (range 0.1-0.53 mmol/kg). At the time of angiography all patients had renal insufficiency (eGFR 2 ). Mean eGFR pre-angiography was 26 ml/min/1.73 m 2 and 33 ml/min/1.73 m 2 post-angiography. The mean follow-up period covers 28 months, range 1-84 months. Additional MRI studies with GDBCA administration were performed in 15 patients. One patient with typical skin lesions had developed biopsy-confirmed NSF. Conventional arterial angiography with GDBCA may play a role in the development of NSF in patients with renal insufficiency. Alternative contrast agents, such as CO 2 angiography or rather the use of low doses of iodinated contrast agents, should be considered in these patients. (orig.)

  16. Retrospective analysis of patients for development of nephrogenic systemic fibrosis following conventional angiography using gadolinium-based contrast agents

    Energy Technology Data Exchange (ETDEWEB)

    Hoppe, Hanno; Spagnuolo, Sara; Froehlich, Johannes M.; Thoeny, Harriet C. [University Hospital Bern, Institute of Diagnostic, Interventional, and Pediatric Radiology, Inselspital, Bern (Switzerland); Nievergelt, Helga [University Hospital Bern, Clinic of Dermatology, Bern (Switzerland); Dinkel, Hans-Peter [Hospital Landshut, Institute of Diagnostic and Interventional Radiology, Landshut (Germany); Gretener, Silvia [University Hospital of Bern, Division of Vascular Medicine, Swiss Cardiovascular Center, Bern (Switzerland)

    2010-03-15

    The purpose was to retrospectively review the data of 27 patients with renal insufficiency who underwent conventional angiography with gadolinium-based contrast agents (GDBCA) as alternative contrast agents and assess the occurrence of nephrogenic systemic fibrosis (NSF) together with associated potential risk factors. This HIPAA-compliant study had institutional review board approval, and informed consent was waived. Statistical analysis was performed for all available laboratory and clinical data, including dermatology reports. Type and amount of the GDBCA used were recorded for angiography and additional MRI studies, if applicable. Serum creatinine levels (SCr) pre- and post-angiography were recorded, and estimated glomerular filtration rates (eGFR) were calculated. Ten female and 17 male patients who underwent angiography with GDBCA were included. The mean amount of GDBCA administered was 44 {+-} 15.5 ml (range 15-60 ml) or 0.24 + 0.12 mmol/kg (range 0.1-0.53 mmol/kg). At the time of angiography all patients had renal insufficiency (eGFR <60 ml/min/1.73 m{sup 2}). Mean eGFR pre-angiography was 26 ml/min/1.73 m{sup 2} and 33 ml/min/1.73 m{sup 2} post-angiography. The mean follow-up period covers 28 months, range 1-84 months. Additional MRI studies with GDBCA administration were performed in 15 patients. One patient with typical skin lesions had developed biopsy-confirmed NSF. Conventional arterial angiography with GDBCA may play a role in the development of NSF in patients with renal insufficiency. Alternative contrast agents, such as CO{sub 2} angiography or rather the use of low doses of iodinated contrast agents, should be considered in these patients. (orig.)

  17. Evaluation of Short-Term Bioassays to Predict Functional Impairment. Selected Short-Term Renal Toxicity Tests.

    Science.gov (United States)

    1980-10-01

    reported using the method of Gentzkow (1942), which involves conversion of urea to ammonia with urease and measurement of the ammonia by...Nesslerization. Methods employing urease are not well suited for automated analysis since an incubation time of about 20 minutes is required for the conversion of...flow or distribution of blood flow through the various layers of renal tissue. Several methods are available for measuring intrarenal hemodynamics; two

  18. Digital subtraction angiography with an Isocon camera system: clinical applications

    International Nuclear Information System (INIS)

    Barbaric, Z.L.; Gomes, A.S.; Deckard, M.E.; Nelson, R.S.; Moler, C.L.

    1984-01-01

    A new imaging system for digital subtraction angiography (DSA) was evaluated in 30 clinical studies. The image receptor is a 25 X 25 cm, 12 par gadolinium oxysulfate rare-earth screen whose light output is focused to a low-light-level Isocon camera. The video signal is digitized and processed by an image-array processor containing 31 512 X 512 memories 8 bits deep. In most patients, intraarterial DSA studies were done in conjunction with conventional arteriography. In these arterial studies, images adequate to make a specific diagnosis were obtained using half the radiation dose and half the amount of contrast material needed for conventional angiography. In eight intravenous studies performed either to identify renal artery stenosis or for evaluation of congenital heart anomalies, the images were diagnostic but objectionably noisy

  19. Dual-Source Dual-Energy CT Angiography of the Supra-Aortic Arteries with Tin Filter: Impact of Tube Voltage Selection.

    Science.gov (United States)

    Korn, Andreas; Bender, Benjamin; Schabel, Christoph; Bongers, Malte; Ernemann, Ulrike; Claussen, Claus; Thomas, Christoph

    2015-06-01

    Automatic bone and plaque subtraction (BPS) in computed tomographic angiographic (CTA) examinations using dual-energy CT (DECT) remains challenging because of beam-hardening artifacts in the shoulder region and close proximity of the internal carotid artery to the base of the skull. The selection of the tube voltage combination in dual-source CT influences the spectral separation and the susceptibility for artifacts. The purpose of this study was to assess which tube voltage combination leads to an optimal image quality of head and neck DECT angiograms after bone subtraction. Fifty-one patients received tin-filter-enhanced DECT angiograms of the supra-aortic arteries using two voltage protocols: 24 patients were studied using 80/Sn140 kV and 27 using a 100/Sn140 kV protocol, both protocols with an additional tin filter. A commercially available DE-CTA BPS algorithm was used. Artificial vessel erosions in BPS maximum intensity projections (four-level Likert scale with CTA source data as reference) and vessel signal-to-noise ratio (SNR) were assessed in the level of the shoulders and the base of the skull in each patient and compared. At the level of the shoulder, 100/Sn140 kV achieved higher SNR (23.4 ± 6.4 at 80/Sn140 kV vs. 35.1 ± 11.8 at 100/Sn140 kV; P supra-aortic arteries than the 80/Sn140 kV protocol. Copyright © 2015 AUR. Published by Elsevier Inc. All rights reserved.

  20. Detection of renal arteries with fast spin-echo magnetic resonance imaging

    Energy Technology Data Exchange (ETDEWEB)

    Tello, R.; Mitchell, P.J.; Witte, D.J.; Thomson, K.R. [University of Melbourne, Parkville, VIC (Australia). Department of Radiology

    1998-08-01

    With the increasing use of non-invasive imaging with MR and volumetric CT to evaluate renal arteries, the ability to accurately detect the number and state of native renal arteries becomes critical if conventional angiography is to be supplanted in these settings. The present study evaluated the utility of a fast spin-echo (FSE) T2-weighted sequence to detect the number and course of renal arteries and their ostia compared to conventional angiography. Ten patients underwent conventional catheter angiography either for renal artery stenosis evaluation or as potential renal donors. Each patient then had an MR study of the renal arteries and kidneys with FSE MR (TR = 4000 ms, TE = 102 ms, eight- echo train length, 5-mm-thick interleaved 128 phase encodes, superior and inferior saturation pulses, number of excitations (NEX) = 4, on a 1.5-T superconducting magnet). Images were reviewed by two `blinded` radiologists and renal arteries were counted and their ostia were evaluated. Results were compared with angiography and inter- and intra-observer statistics were calculated. All 10 patients underwent MR successfully, nine for renal artery stenosis (RAS) evaluation and one was a renal donor. A total of 24 renal arteries were imaged in 19 kidneys. Fast spin-echo MR is 95% accurate (95%CI: 88-100%) in detection of renal arteries, with no statistical difference between FSE MR and catheter angiography (McNemar P = 0.0). Inter- and intra-observer statistics demonstrate good-to-excellent agreement in renal artery detection (kappa: 0.63-0.90). In one case of RAS evaluation an incidental adrenal mass was detected as the aetiology of the patient`s hypertension. Fast spin-echo MR can be a useful adjunct as part of the imaging for renal arteries with MRI. Copyright (1998) Blackwell Science Pty Ltd 16 refs., 1 fig.

  1. Detection of renal arteries with fast spin-echo magnetic resonance imaging

    International Nuclear Information System (INIS)

    Tello, R.; Mitchell, P.J.; Witte, D.J.; Thomson, K.R.

    1998-01-01

    With the increasing use of non-invasive imaging with MR and volumetric CT to evaluate renal arteries, the ability to accurately detect the number and state of native renal arteries becomes critical if conventional angiography is to be supplanted in these settings. The present study evaluated the utility of a fast spin-echo (FSE) T2-weighted sequence to detect the number and course of renal arteries and their ostia compared to conventional angiography. Ten patients underwent conventional catheter angiography either for renal artery stenosis evaluation or as potential renal donors. Each patient then had an MR study of the renal arteries and kidneys with FSE MR (TR = 4000 ms, TE = 102 ms, eight- echo train length, 5-mm-thick interleaved 128 phase encodes, superior and inferior saturation pulses, number of excitations (NEX) = 4, on a 1.5-T superconducting magnet. Images were reviewed by two 'blinded' radiologists and renal arteries were counted and their ostia were evaluated. Results were compared with angiography and inter- and intra-observer statistics were calculated. All 10 patients underwent MR successfully, nine for renal artery stenosis (RAS) evaluation and one was a renal donor. A total of 24 renal arteries were imaged in 19 kidneys. Fast spin-echo MR is 95% accurate (95%CI: 88-100%) in detection of renal arteries, with no statistical difference between FSE MR and catheter angiography (McNemar P = 0.0). Inter- and intra-observer statistics demonstrate good-to-excellent agreement in renal artery detection (kappa: 0.63-0.90). In one case of RAS evaluation an incidental adrenal mass was detected as the aetiology of the patient's hypertension. Fast spin-echo MR can be a useful adjunct as part of the imaging for renal arteries with MRI. Copyright (1998) Blackwell Science Pty Ltd

  2. Digital angiography in pulmonary embolism

    International Nuclear Information System (INIS)

    Bjoerk, L.

    1986-01-01

    Pulmonary digital subtraction angiography was diagnostic in 98.3% of patients with possible acute pulmonary embolism. The procedure was well tolerated even in severely ill patients. A large image intensifier made simultaneous imaging of both lungs possible reducing the number of contrast injections necessary. Small volumes of low iso-osmolar concentration of modern contrast media were used. There was no need for catherization of the pulmonary artery. Theoretical considerations and our limited experience indicate that this will reduce the number of complications compared with conventional pulmonary angiography. The procedure is rapidly performed and the diagnostic accuracy high. This makes digital subtraction angiography cost effective. Digital pulmonary angiography can be recommended as the primary diagnostic method in most patients with possible pulmonary embolism. (orig.)

  3. Comparison of gadofosveset-enhanced three-dimensional magnetic resonance angiography with digital subtraction angiography for lower-extremity peripheral arterial occlusive disease

    International Nuclear Information System (INIS)

    Grijalba, Fermin Urtasun; Esandi, Mercedes Ciriza

    2010-01-01

    Background: Minimally invasive imaging techniques are increasingly used for clinical decision making in patients with peripheral arterial occlusive disease (PAOD). Purpose: To assess whether gadofosveset-enhanced three-dimensional (3D) magnetic resonance (MR) angiography could replace digital subtraction angiography (DSA) for the evaluation of lower-extremity PAOD. Material and Methods: Thirty patients with symptomatic PAOD underwent prospectively both MR angiography and DSA. Gadofosveset-enhanced 3D MR angiography was performed on a 1.5T system equipped with a peripheral angio matrix coil. Four blinded observers independently analyzed MR angiograms and DSA images. The lower arterial vascular system was divided into three anatomic segments (aortoiliac, femoropopliteal, infrapopliteal) for review. The status of each segment was graded as normal, stenosis less than 50%, stenosis greater than 50%, or occluded and/or aneurismatic. Principal and secondary lesions were reported. Results: Although interobserver agreement for both was excellent, it was higher for DSA (?=0.92) than for MR angiography (?=0.86) for reporting the principal and secondary lesions in all segments. For different anatomic locations, the interobserver agreement of MR angiography and DSA was as follows: aortoiliac (?=0.93, k=0.95), femoropopliteal (?=0.86, k=0.90), and infrapopliteal (?=0.78, k=0.85). The lowest agreement was found for MR angiography on infrapopliteal segments (?=0.78). In four (13.3%) cases, MR angiography showed lesions that were not found by DSA. Five (16.6%) aneurysm cases, not observed by DSA, were shown by MR angiography. Conclusion: Gadofosveset-enhanced 3D MR angiography can be proposed for first-line imaging in the management of lower-limb PAOD patients and permits the selective use of DSA as a second-line examination when MR angiography fails or in an endovascular approach

  4. Time-resolved CT angiography in aortic dissection

    International Nuclear Information System (INIS)

    Meinel, Felix G.; Nikolaou, Konstantin; Weidenhagen, Rolf; Hellbach, Katharina; Helck, Andreas; Bamberg, Fabian; Reiser, Maximilian F.; Sommer, Wieland H.

    2012-01-01

    Objectives: We performed this study to assess feasibility and additional diagnostic value of time-resolved CT angiography of the entire aorta in patients with aortic dissection. Materials and methods: 14 consecutive patients with known or suspected aortic dissection (aged 60 ± 9 years) referred for aortic CT angiography were scanned on a dual-source CT scanner (Somatom Definition Flash; Siemens, Forchheim, Germany) using a shuttle mode for multiphasic image acquisition (range 48 cm, time resolution 6 s, 6 phases, 100 kV, 110 mAs/rot). Effective radiation doses were calculated from recorded dose length products. For all phases, CT densities were measured in the aortic lumen and renal parenchyma. From the multiphasic data, 3 phases corresponding to a triphasic standard CT protocol, served as a reference and were compared against findings from the time-resolved datasets. Results: Mean effective radiation dose was 27.7 ± 3.5 mSv. CT density of the true lumen peaked at 355 ± 53 HU. Compared to the simulated triphasic protocol, time-resolved CT angiography added diagnostic information regarding a number of important findings: the enhancement delay between true and false lumen (n = 14); the degree of membrane oscillation (n = 14); the perfusion delay in arteries originating from the false lumen (n = 9). Other additional information included true lumen collapse (n = 4), quantitative assessment of renal perfusion asymmetry (n = 2), and dynamic occlusion of aortic branches (n = 2). In 3/14 patients (21%), these additional findings of the multiphasic protocol altered patient management. Conclusions: Multiphasic, time-resolved CT angiography covering the entire aorta is feasible at a reasonable effective radiation dose and adds significant diagnostic information with therapeutic consequences in patients with aortic dissection.

  5. New method of digital angiography

    International Nuclear Information System (INIS)

    Hashiya, Junichi; Korenaga, Takeo; Sakurai, Kenji; Sakai, Fumikazu; Kato, Hisatoyo; Takano, Masao.

    1982-01-01

    New experience of digital angiography using Fuji Intelligent Diagnostic X-ray System was reported. The system utilizes newly developed high sensitivity imaging plate in conjunction with computerized image processor instead of image intensifier-TV series, thus drastically improving image quality. Initial clinical trial was made in 46 cases including intravenous digital subtraction angiography and transcatheter digital arteriography. The advantages of this method were summerized as: 1. better resolution, 2. wider field size, 3. more sophisticated image manipulation program. (author)

  6. Renal Osteodystrophy

    Directory of Open Access Journals (Sweden)

    Aynur Metin Terzibaşoğlu

    2004-12-01

    Full Text Available Chronic renal insufficiency is a functional definition which is characterized by irreversible and progressive decreasing in renal functions. This impairment is in collaboration with glomeruler filtration rate and serum creatinine levels. Besides this, different grades of bone metabolism disorders develop in chronic renal insufficiency. Pathologic changes in bone tissue due to loss of renal paranchyme is interrelated with calcium, phosphorus vitamine-D and parathyroid hormone. Clinically we can see high turnover bone disease, low turnover bone disease, osteomalacia, osteosclerosis and osteoporosis in renal osteodystropy. In this article we aimed to review pathology of bone metabolism disorders due to chronic renal insufficiency, clinic aspects and treatment approaches briefly.

  7. 3D Deep Learning Angiography (3D-DLA) from C-arm Conebeam CT.

    Science.gov (United States)

    Montoya, J C; Li, Y; Strother, C; Chen, G-H

    2018-05-01

    Deep learning is a branch of artificial intelligence that has demonstrated unprecedented performance in many medical imaging applications. Our purpose was to develop a deep learning angiography method to generate 3D cerebral angiograms from a single contrast-enhanced C-arm conebeam CT acquisition in order to reduce image artifacts and radiation dose. A set of 105 3D rotational angiography examinations were randomly selected from an internal data base. All were acquired using a clinical system in conjunction with a standard injection protocol. More than 150 million labeled voxels from 35 subjects were used for training. A deep convolutional neural network was trained to classify each image voxel into 3 tissue types (vasculature, bone, and soft tissue). The trained deep learning angiography model was then applied for tissue classification into a validation cohort of 8 subjects and a final testing cohort of the remaining 62 subjects. The final vasculature tissue class was used to generate the 3D deep learning angiography images. To quantify the generalization error of the trained model, we calculated the accuracy, sensitivity, precision, and Dice similarity coefficients for vasculature classification in relevant anatomy. The 3D deep learning angiography and clinical 3D rotational angiography images were subjected to a qualitative assessment for the presence of intersweep motion artifacts. Vasculature classification accuracy and 95% CI in the testing dataset were 98.7% (98.3%-99.1%). No residual signal from osseous structures was observed for any 3D deep learning angiography testing cases except for small regions in the otic capsule and nasal cavity compared with 37% (23/62) of the 3D rotational angiographies. Deep learning angiography accurately recreated the vascular anatomy of the 3D rotational angiography reconstructions without a mask. Deep learning angiography reduced misregistration artifacts induced by intersweep motion, and it reduced radiation exposure

  8. Digital subtraction angiography in cardiac diseases

    International Nuclear Information System (INIS)

    Choi, Deuk Lin; Kim, Ki Jeong

    1986-01-01

    DSA was done in 133 examinations of 128 patients during 2 years consist of 9 examination of IV DSA and 124 examination of selective cardiac DSA after cardiac catheterization. Open heart surgery was performed in 90 patients and 12 patients showed discrepancy between pre-and post operative diagnosis, showing a total 86.7% of diagnostic accuracy with DSA. We experienced the significant reduction in dose of contrast media, 30-40% of dose of conventional cardiac angiography. It is concluded that DSA is useful in the evaluation of septal defects, valvular disease and other congenital heart disease. DSA is an accurate simple and safe method in evaluating of cardiac diseases.

  9. Captopril 99mTc-DTPA Renal Scintigraphy in Diagnosis of Renovascular Hypertension

    International Nuclear Information System (INIS)

    Yang, In Hyung; Lee, Dong Soo; Kim, Sung Chul

    1992-01-01

    To evaluate the sensitivity and specificity of captopril renal scan for renovascular hypertension, we employed the captopril renal scan in conjunction with renal angiography in 81 patients, 159 kidneys, who were referred to evaluate the cause of hypertension. We defined the renovascular hypertension by the criteria of demonstration of renal artery stenosis by angiography, and improvement or cure of hypertension by revascularization. Visual and quantitative evaluation of 99m Tc-DTPA renal scan was performed pre and post captopril administration. The prevalence rate of renovascular hypertension was 40% in comparing with renal angiography, and 70% in confirmed cases. The causes of renovascular hypertension in 81 patients were Takayasu's arteritis, fibromuscular dysplasia, atherosclerosis, essential hypertension, chronic pyelonephritis etc. The sensitivity and specificity of captopril renal scan in comparing with renal angiography were 80%, 86.5%, respectively and also 84.2%, 72.6% in confirmed cases of renovascular hypertension, respectively. The causes of false negative cases were nonfunctioning kidney due to complete obstruction or long duration of disease in basal scan, segmental branch artery stenosis, unknown causes, and suspicious true negative cases without confirmation. The false positive cases were abdominal aortic stenosis or aneurysm, dehydration, unknown causes, and suspicious true positive cases. We conclude that captopril renal scintigraphy is highly sensitive, reasonably specific diagnostic method and comparable to other techniques very favorably.

  10. Renal venogram

    Science.gov (United States)

    ... be black. Other structures will be shades of gray. Veins are not normally seen in an x- ... Venogram - kidney; Renal vein thrombosis - venogram Images Kidney anatomy Kidney - blood and urine flow Renal veins References ...

  11. Magnetic resonance angiography vs. angiography in tetralogy of Fallot.

    Science.gov (United States)

    Rao, Uppalapati Venkateswara; Vanajakshamma, Velam; Rajasekhar, Durgaprasad; Lakshmi, Amancharla Yadagiri; Reddy, Reddivari Niranjan

    2013-08-01

    : To determine whether gadolinium-enhanced three-dimensional magnetic resonance angiography can provide a noninvasive alternative to diagnostic catheterization for evaluation of pulmonary artery anatomy in tetralogy of Fallot. Thirty-five consecutive patients with tetralogy of Fallot, who attended the cardiology outpatient department between January 2008 and December 2009, were included in the study. There were 21 males and 14 females, with a mean age of 9 ± 4.15 years (range, 3-21 years). Thirty-two patients had tetralogy of Fallot with varying severities of valvular and infundibular stenosis. Three patients had tetralogy of Fallot with pulmonary atresia. All patients underwent both cardiac catheterization with X-ray angiography and 3-dimensional magnetic resonance angiography within one month. Measurements of right and left pulmonary arteries and aortopulmonary collaterals were equal by both methods. There was a good correlation between magnetic resonance angiography and catheterization measurements of branch pulmonary arteries. Gadolinium-enhanced three-dimensional magnetic resonance angiography can be used as a reliable noninvasive alternative to X-ray cineangiography for delineation of pulmonary arterial anatomy in sick infants and young children, obviating the need for catheterization.

  12. Multidetector CT angiography in Takayasu arteritis

    Energy Technology Data Exchange (ETDEWEB)

    Khandelwal, Niranjan; Kalra, Naveen [Department of Radiodiagnosis and Imaging, Post Graduate Institute of Medical Education and Research, Chandigarh 160012 (India); Garg, Mandeep Kumar, E-mail: gargmandeep@hotmail.com [Department of Radiodiagnosis and Imaging, Post Graduate Institute of Medical Education and Research, Chandigarh 160012 (India); Kang, Mandeep; Lal, Anupam [Department of Radiodiagnosis and Imaging, Post Graduate Institute of Medical Education and Research, Chandigarh 160012 (India); Jain, Sanjay [Department of Internal Medicine, Post Graduate Institute of Medical Education and Research, Chandigarh 160012 (India); Suri, Sudha [Department of Radiodiagnosis and Imaging, Post Graduate Institute of Medical Education and Research, Chandigarh 160012 (India)

    2011-02-15

    Objective: To analyse the spectrum of Takayasu's arteritis (TA) on multidetector CT angiography (MDCTA). Materials and methods: A retrospective analysis of the MDCTA findings was performed on 15 patients clinically diagnosed as Takayasu's arteritis. The spectrum and incidence of imaging findings on CTA were compared to studies in literature on catheter angiography in Takayasu's arteritis. Laboratory parameters were available in nine patients. The disease was considered active if erythrocyte sedimentation rate (ESR) levels were elevated and 'C' reactive protein (CRP) was positive. An attempt was made to correlate disease activity with the imaging findings. Results: Ascending aorta, arch of aorta and descending thoracic aorta were involved in 14 out of 15 (93%) patients. The wall thickness varied between 1 and 10 mm with maximal involvement in arch and descending thoracic aorta. Major neck vessels were involved in 11 (73%) patients with most pronounced changes seen in the brachiocephalic trunk, left common carotid artery (CCA) and left subclavian artery (SCA). Abdominal aorta and its branches were involved in all the 11 (100%) patients in whom abdominal CTA was performed. Celiac axis and SMA were involved in 10 (91%) and seven (64%) patients, respectively while renal artery stenosis was present in five (45%) patients. In six patients, ESR was elevated and CRP was positive indicating active disease. All patients in whom the laboratory parameters were available showed mural thickening in the aorta and at least one of the neck vessels except for one patient with inactive disease who had aortic mural thickening only. Conclusion: MDCTA provides information about both the vessel wall and lumen in patients with Takayasu's disease.

  13. Dual source multidetector CT-angiography before transcatheter aortic valve implantation (TAVI) using a high-pitch spiral acquisition mode

    Energy Technology Data Exchange (ETDEWEB)

    Wuest, W.; Anders, K.; May, M.S.; Uder, M. [University of Erlangen, Department of Radiology, Erlangen (Germany); Schuhbaeck, A.; Gauss, S.; Marwan, M.; Arnold, M.; Muschiol, G.; Daniel, W.G.; Achenbach, S. [University of Erlangen, Department of Cardiology, Erlangen (Germany); Ensminger, S. [University of Erlangen, Department of Cardiac Surgery, Erlangen (Germany)

    2012-01-15

    Transcatheter Aortic Valve Implantation (TAVI) is an alternative to surgical valve replacement in high risk patients. Angiography of the aortic root, aorta and iliac arteries is required to select suitable candidates, but contrast agents can be harmful due to impaired renal function. We evaluated ECG-triggered high-pitch spiral dual source Computed Tomography (CT) with minimized volume of contrast agent to assess aortic root anatomy and vascular access. 42 patients (82 {+-} 6 years) scheduled for TAVI underwent dual source (DS) CT angiography (CTA) of the aorta using a prospectively ECG-triggered high-pitch spiral mode (pitch = 3.4) with 40 mL iodinated contrast agent. We analyzed aortic root/iliac dimensions, attenuation, contrast to noise ratio (CNR), image noise and radiation exposure. Aortic root/iliac dimensions and distance of coronary ostia from the annulus could be determined in all cases. Mean aortic and iliac artery attenuation was 320 {+-} 70 HU and 340 {+-} 77 HU. Aortic/iliac CNR was 21.7 {+-} 6.8 HU and 14.5 {+-} 5.4 HU using 100 kV (18.8 {+-} 4.1 HU and 8.7 {+-} 2.6 HU using 120 kV). Mean effective dose was 4.5 {+-} 1.2 mSv. High-pitch spiral DSCTA can be used to assess the entire aorta and iliac arteries in TAVI candidates with a low volume of contrast agent while preserving diagnostic image quality. (orig.)

  14. 2D MR angiography of the aortic aneurysm

    International Nuclear Information System (INIS)

    Amanuma, Makoto; Hasegawa, Makoto; Watabe, Tsuneya; Heshiki, Atsuko

    1992-01-01

    2D time-of-flight MR angiography was performed in 6 cases of thoracic aortic aneurysm. Oblique saturation pulses were used to suppress the signals of the pulmonary artery and SVC, providing excellent selective MR aortograms. Three dimensional extension of the aneurysm and its relation with cervical branches were easily assessed. It could be possible to replace invasive aortography by this technique. (author)

  15. Renal rescue of dopamine D2 receptor function reverses renal injury and high blood pressure

    Science.gov (United States)

    Konkalmatt, Prasad R.; Asico, Laureano D.; Zhang, Yanrong; Yang, Yu; Drachenberg, Cinthia; Zheng, Xiaoxu; Han, Fei; Jose, Pedro A.; Armando, Ines

    2016-01-01

    Dopamine D2 receptor (DRD2) deficiency increases renal inflammation and blood pressure in mice. We show here that long-term renal-selective silencing of Drd2 using siRNA increases renal expression of proinflammatory and profibrotic factors and blood pressure in mice. To determine the effects of renal-selective rescue of Drd2 expression in mice, the renal expression of DRD2 was first silenced using siRNA and 14 days later rescued by retrograde renal infusion of adeno-associated virus (AAV) vector with DRD2. Renal Drd2 siRNA treatment decreased the renal expression of DRD2 protein by 55%, and DRD2 AAV treatment increased the renal expression of DRD2 protein by 7.5- to 10-fold. Renal-selective DRD2 rescue reduced the expression of proinflammatory factors and kidney injury, preserved renal function, and normalized systolic and diastolic blood pressure. These results demonstrate that the deleterious effects of renal-selective Drd2 silencing on renal function and blood pressure were rescued by renal-selective overexpression of DRD2. Moreover, the deleterious effects of 45-minute bilateral ischemia/reperfusion on renal function and blood pressure in mice were ameliorated by a renal-selective increase in DRD2 expression by the retrograde ureteral infusion of DRD2 AAV immediately after the induction of ischemia/reperfusion injury. Thus, 14 days after ischemia/reperfusion injury, the renal expression of profibrotic factors, serum creatinine, and blood pressure were lower in mice infused with DRD2 AAV than in those infused with control AAV. These results indicate an important role of renal DRD2 in limiting renal injury and preserving normal renal function and blood pressure. PMID:27358912

  16. Diagnosis of echinococcosis of the liver by angiography

    International Nuclear Information System (INIS)

    Schulze, K.; Treugut, H.; Mahnke, B.; Barth, V.; Katharinenhospital, Stuttgart

    1980-01-01

    Twenty patients with Echinococcus cysticus and 15 with E. alveolaris were studied. Selective upper abdominal angiographies, performed in most of these cases, were reviewed retrospectively for typical angiographic changes. In a large percentage, E. cysticus demonstrated typical cystic and expansive signs; atypical vessels were rarely seen. How the 'rim sign' develops is demonstrated. Usual signs of E. alveolaris are incomplete solid and necrotic space occupying lesions, as seen also in malignancy. Although angiography offers a high diagnostic rate in hepatic manifestation of this parasitic disease, it has been superseded today by sonography and computer tomography. It is, however, still a valuable investigation in pre-operative work-up. (orig.) [de

  17. Diagnosis of echinococcosis of the liver by angiography

    Energy Technology Data Exchange (ETDEWEB)

    Schulze, K.; Treugut, H.; Mahnke, B.; Barth, V.

    1980-07-01

    Twenty patients with Echinococcus cysticus and 15 with E. alveolaris were studied. Selective upper abdominal angiographies, performed in most of these cases, were reviewed retrospectively for typical angiographic changes. In a large percentage, E. cysticus demonstrated typical cystic and expansive signs; atypical vessels were rarely seen. How the 'rim sign' develops is demonstrated. Usual signs of E. alveolaris are incomplete solid and necrotic space occupying lesions, as seen also in malignancy. Although angiography offers a high diagnostic rate in hepatic manifestation of this parasitic disease, it has been superseded today by sonography and computer tomography. It is, however, still a valuable investigation in pre-operative work-up.

  18. Uterine artery embolization angiography and fertility related aspects

    Directory of Open Access Journals (Sweden)

    Irina A. Horhoianu

    2016-05-01

    Full Text Available Purpose. Uterine artery embolization is a minimally invasive technique. It applies the principle of targeted anatomical structure devascularisation with utility in fibroid conservative therapy, including for future fertility preserving status. The objective of our paper represents a description and evaluation of angiography utility as a predictive method for fertility maintenance. Material and Methods. The angiography and ultrasound aspects obtained from a prospective study in which selected patients have undergone uterine artery embolization for fertility preservation are detailed. Results. The following angiography aspects have been detected: left- right shunt and utero-ovarian collaterals; these have been compared with the ultrasound aspects related to the fibroid evolution form a volumetric and Doppler ultrasound point of view. The angiographical description predicts the impact on post embolization fibroid evolution and upon fertility. An analysis is made in order to assess the way in which angiography can contribute to fertility alteration. Conclusions. The angiography aspects during embolization and the following ultrasound aspects can represent predictive factors as to fertility evolution after uterine artery embolization.

  19. Breath-hold imaging of the coronary arteries using Quiescent-Interval Slice-Selective (QISS) magnetic resonance angiography: pilot study at 1.5 Tesla and 3 Tesla.

    Science.gov (United States)

    Edelman, Robert R; Giri, S; Pursnani, A; Botelho, M P F; Li, W; Koktzoglou, I

    2015-11-23

    Coronary magnetic resonance angiography (MRA) is usually obtained with a free-breathing navigator-gated 3D acquisition. Our aim was to develop an alternative breath-hold approach that would allow the coronary arteries to be evaluated in a much shorter time and without risk of degradation by respiratory motion artifacts. For this purpose, we implemented a breath-hold, non-contrast-enhanced, quiescent-interval slice-selective (QISS) 2D technique. Sequence performance was compared at 1.5 and 3 Tesla using both radial and Cartesian k-space trajectories. The left coronary circulation was imaged in six healthy subjects and two patients with coronary artery disease. Breath-hold QISS was compared with T2-prepared 2D balanced steady-state free-precession (bSSFP) and free-breathing, navigator-gated 3D bSSFP. Approximately 10 2.1-mm thick slices were acquired in a single ~20-s breath-hold using two-shot QISS. QISS contrast-to-noise ratio (CNR) was 1.5-fold higher at 3 Tesla than at 1.5 Tesla. Cartesian QISS provided the best coronary-to-myocardium CNR, whereas radial QISS provided the sharpest coronary images. QISS image quality exceeded that of free-breathing 3D coronary MRA with few artifacts at either field strength. Compared with T2-prepared 2D bSSFP, multi-slice capability was not restricted by the specific absorption rate at 3 Tesla and pericardial fluid signal was better suppressed. In addition to depicting the coronary arteries, QISS could image intra-cardiac structures, pericardium, and the aortic root in arbitrary slice orientations. Breath-hold QISS is a simple, versatile, and time-efficient method for coronary MRA that provides excellent image quality at both 1.5 and 3 Tesla. Image quality exceeded that of free-breathing, navigator-gated 3D MRA in a much shorter scan time. QISS also allowed rapid multi-slice bright-blood, diastolic phase imaging of the heart, which may have complementary value to multi-phase cine imaging. We conclude that, with further clinical

  20. Breath-hold two-dimensional MR angiography of coronary arteries. Comparison with conventional coronary angiography in ten cases

    International Nuclear Information System (INIS)

    Li Liwei; Zhang Wanshi; Liu Chaozhong; Lu Xiaoyan; Xu Jiaxing

    1997-01-01

    Purpose: To assess the diagnostic value of two-dimensional coronary magnetic resonance (MR) angiography in patients evaluated for ischemic heart disease. Materials and methods: Ten patients who underwent selective cardiac catheterization with coronary MR angiography were evaluated with two-dimensional coronary MR angiography. Coronary MR angiography was performed with breath-hold fat-suppressed ECG-gated Turbo-FLASH with K-space segmentation using a 1.5 T imager. Results: The left main coronary artery, proximal left anterior descending artery, circumflex artery and right coronary artery were demonstrated in all cases. Continuous segments (mean) of left anterior descending, circumflex and right coronary arteries visualized on MRA were 6.72 +- 3.16 cm, 3.67 +- 4.81 cm and 7.93 +- 3.12 cm respectively. The overall sensitivity for detection of hemodynamically significant coronary artery lesion (≥50%) was 62.5% respectively. Conclusion: Breath-hold two-dimensional coronary MR angiography was useful in showing relatively long segments of the main coronary arteries and also has potential in depicting hemodynamically significant coronary artery lesions

  1. Renal perfusion scintiscan

    Science.gov (United States)

    ... Radionuclide renal perfusion scan; Perfusion scintiscan - renal; Scintiscan - renal perfusion Images Kidney anatomy Kidney - blood and urine flow Intravenous pyelogram References Rottenberg G, Andi AC. Renal ...

  2. Treatment of arteriovenous malformations with stereotactic radiosurgery employing both magnetic resonance angiography and standard angiography as a database

    International Nuclear Information System (INIS)

    Petereit, D.; Mehta, M.; Turski, P.; Levin, A.; Strother, C.; Mistretta, C.; Mackie, R.; Gehring, M.; Kubsad, S.; Kinsella, T.

    1993-01-01

    Twenty-one arteriovenous malformations were prospectively evaluated using magnetic resonance angiography, compare it to stereotactic angiography, employ magnetic resonance angiography in follow-up, and semiquanitfy flow. A correlative evaluation between flow and response to stereotactic radiosurgery was carried out. Phase contrast angiograms were obtained at flow velocities of 400, 200, 100, 60 and 20 cm/sec. The fractionated velocities provided images that selectively demonstrated the arterial and venous components of the arteriovenous malformations. Qualitative assessment of the velocity within the arteriovenous malformations and the presence of fistulae were also determined by multiple velocity images. In addition, 3-dimensional time-of-flight magnetic resonance angiograms were obtained to define the exact size and shape of the nidus. This technique also permitted evaluation of the nidus and feeding arteries for the the presence of low flow aneurysms. Correlation between the two imaging modalities was carried out by subjective and semiquantitative estimation of flow velocity and estimation of nidus size. The following velocity parameters were employed: fast, intermediate, slow, and none. Early analysis suggests that slower flowing arteriovenous malformations may obliterate faster after stereotactic radiosurgery an flow parameters should be employed to predict response. In conclusion, magnetic resonance angiography permits semiquantitative flow velocity assessment and may therefore be superior to stereotactic angiography. An additional advantage of magnetic resonance angiography is the generation of serial transverse images which can replace the conventional CT scan employed for stereotactic radiosurgery treatment planning. A single diagnostic test may therefore be used for diagnosis, radiosurgical treatment planning, follow-up, and treatment selection by identifying patients likely to respond early to radiosurgical management

  3. Fluorescence angiography in retinal tumours

    International Nuclear Information System (INIS)

    Fuhrmann, M.

    1980-01-01

    On the basis of the available photographic material the results of fluorescein angiography are reported in 4 cases of retinoblastoma and 3 cases of Bourneville's disease. The clinical diagnosis of retinoblastoma was confirmed histologically in all cases since the first eye had been removed for the same reason previously. One child had not yet been treated, and in 3 cases radioactive isotopes were used in the treatment. In the group of phacomatosis the patients had only periodical outpatient examinations. The importance of this angiography in the diagnosis and follow-up of these diseases is stressed. (author)

  4. Fluorescence angiography in retinal tumours

    Energy Technology Data Exchange (ETDEWEB)

    Fuhrmann, M [Staedtisches Klinikum Berlin-Buch (German Democratic Republic)

    1980-01-01

    On the basis of the available photographic material the results of fluorescein angiography are reported in 4 cases of retinoblastoma and 3 cases of Bourneville's disease. The clinical diagnosis of retinoblastoma was confirmed histologically in all cases since the first eye had been removed for the same reason previously. One child had not yet been treated, and in 3 cases radioactive isotopes were used in the treatment. In the group of phacomatosis the patients had only periodical outpatient examinations. The importance of this angiography in the diagnosis and follow-up of these diseases is stressed.

  5. Bilateral anomalous drainage of the posterior divisions of renal veins into the azygos venous system in a 20-year-old woman: a case report.

    Science.gov (United States)

    Pallangyo, Pedro; Lyimo, Frederick; Nicholaus, Paulina; Masatu, Stephano; Janabi, Mohamed

    2016-12-03

    Renal vein anomalies are relatively infrequent and generally asymptomatic. Preoperative knowledge of such variants is, however, of paramount importance in several angiographic and surgical procedures including renal venography, renal vein sampling, spermatic embolization, and renal transplantation. Inadequate knowledge and failure to recognize such anatomic variations may lead to several operative hazards including hemorrhage, nephrectomy, and even death. We report a case of bilateral anomalous drainage of the posterior divisions of renal veins into the azygos venous system in a 20-year-old woman of African descent from Tanzania who presented to us with a 12-year history of recurrent anemia. She had anemia, a positive sickling test, and hemoglobin electrophoresis revealed a sickle cell trait (AS). She underwent computed tomography angiography of her chest and abdomen to rule out the presence of arteriovenous malformations. Aortography findings were normal but venography results revealed features of tortuously dilated azygos and hemiazygos veins each receiving blood from its respective posterior division of renal vein. Although venous anomalies are relatively infrequent and generally lack a clinical significance, a thorough understanding of embryologic development and its associated errors is of immense importance in equipping angiographers and surgeons to select appropriate interventional/operative techniques, anticipate risks, and prevent intervention-related complications.

  6. Myocardial perfusion imaging by digital subtraction angiography

    International Nuclear Information System (INIS)

    Kadowaki, Hiroyuki; Ishikawa, Kinji; Ogai, Toshihiro; Katori, Ryo

    1986-01-01

    Several methods of digital subtraction angiography (DSA) were compared to determine which could better visualize regional myocardial perfusion using coronary angiography in seven patients with myocardial infarction, two with angina pectoris and five with normal coronary arteries. Satisfactory DSA was judged to be achieved if the shape of the heart on the mask film was identical to that on the live film and if both films were exactly superimposed. To obtain an identical mask film in the shape of each live film, both films were selected from the following three phases of the cardiac cycle; 1) at the R wave of the electrocardiogram, 2) 100 msec before the R wave, and 3) 200 msec before the R wave. The last two were superior for obtaining mask and live films which were similar in shape, because the cardiac motion in these phases was relatively small. Using these mask and live films, DSA was performed either with the continuous image mode (CI mode) or the time interval difference mode (TID mode). The overall perfusion of contrast medium through the artery to the vein was adequately visualized using the CI mode. Passage of contrast medium through the artery, capillary and vein was visualized at each phase using TID mode. Subtracted images were displayed and photographed, and the density of the contrast medium was adequate to display contour lines as in a relief map. Using this DSA, it was found that regional perfusion of the contrast medium was not always uniform in normal subjects, depending on the typography of the coronary artery. In all patients with anterior myocardial infarction, low perfusion was observed at the infarcted portion compared to the non-infarcted myocardium. In patients with inferior myocardial infarction, this low perfusion area was not observed because right coronary angiography was not subjected to DSA in this study. (J.P.N.)

  7. MDCT angiography and transcatheter embolization in management ...

    African Journals Online (AJOL)

    Hassan Abdelsalam

    2015-12-18

    Dec 18, 2015 ... 14 patients did not have a MDCT and proceeded straight to angiography;. 6 of them showed active bleeding on angiography. Conclusion: MDCT is an excellent technique before angiography and embolization in cases with acute gastrointestinal bleeding. Transcatheter embolization is an effective tool for ...

  8. [Small renal mass].

    Science.gov (United States)

    Prokofiev, D; Kreutzer, N; Kress, A; Wissing, F; Pfeifer, H; Stolzenburg, J-U; Dietel, A; Schwalenberg, T; Do, M; Truß, M C

    2012-10-01

    The frequent application of ultrasound and radiological imaging for non-urological indications in recent years has resulted in an increase in the diagnosis of small renal masses. The treatment options for patients with a small renal mass include active surveillance, surgery (both open and minimally invasive) as well as ablative techniques. As there is a risk for metastatic spread even in small renal masses surgical extirpation remains the treatment of choice in most patients. Ablative procedures, such as cryoablation and radiofrequency ablation are appropriate for old and multi-morbid patients who require active treatment of a small renal mass. Active surveillance is an alternative for high-risk patients. Meticulous patient selection by the urologist and patient preference will determine the choice of treatment option in the future.

  9. Multidetector computed tomography for preoperative evaluation of vascular anatomy in living renal donors.

    Science.gov (United States)

    Türkvatan, Aysel; Akinci, Serkan; Yildiz, Sener; Olçer, Tülay; Cumhur, Turhan

    2009-04-01

    Currently, multidetector computed tomographic (MDCT) angiography has become a noninvasive alternative imaging modality to catheter renal angiography for the evaluation of renal vascular anatomy in living renal donors. In this study, we investigated the diagnostic accuracy of 16-slice MDCT in the preoperative assessment of living renal donors. Fifty-nine consecutive living renal donors (32 men, 27 women) underwent MDCT angiography followed by open donor nephrectomy. All MDCT studies were performed by using a 16-slice MDCT scanner with the same protocol consisting of arterial and nephrographic phases followed by conventional abdominal radiography. The MDCT images were assessed retrospectively for the number and branching pattern of the renal arteries and for the number and presence of major or minor variants of the renal veins. The results were compared with open surgical results. The sensitivity and specificity of MDCT for the detection of anatomic variants of renal arteries including the accessory arteries (n = 9), early arterial branching (n = 7) and major renal venous anomalies including the accessory renal veins (n = 3), late venous confluence (n = 4), circumaortic (n = 2) or retroaortic (n = 3) left renal veins were 100%. However, the sensitivity for identification of minor venous variants was 79%. All of three ureteral duplications were correctly identified at excretory phase conventional abdominal radiography. Sixteen-slice MDCT is highly accurate for the identification of anatomic variants of renal arteries and veins. Dual-phase MDCT angiography including arterial and nephrographic phases followed by conventional abdominal radiography enables complete assessment of renal donors without significant increase of radiation dose. However, the evaluation of minor venous variants may be problematic because of their small diameters and poor opacification.

  10. Measuring the quality of renal care: things to keep in mind when selecting and using quality indicators.

    Science.gov (United States)

    van der Veer, Sabine N; van Biesen, Wim; Couchoud, Cécile; Tomson, Charles R V; Jager, Kitty J

    2014-08-01

    This educational paper discusses a variety of indicators that can be used to measure the quality of care in renal medicine. Based on what aspect of care they reflect, indicators can be grouped into four main categories: structure, process, surrogate outcome and outcome indicators. Each category has its own advantages and disadvantages, and we give some pointers on how to balance these pros and cons while taking into account the aim of the measurement initiative. Especially within initiatives that link payment or reputation to indicator measurement, this balancing should be done with utmost care to avoid potential, unintended consequences. Furthermore, we suggest consideration of (i) a causal chain-i.e. subsequent aspects of care connected by evidence-based links-as a starting point for composing a performance indicator set and (ii) adequate case-mix adjustment, not only of (surrogate) outcomes, but also of process indicators in order to obtain fair comparisons between facilities and within facilities over time. © The Author 2013. Published by Oxford University Press on behalf of ERA-EDTA. All rights reserved.

  11. Cost analysis of procedures related to the management of renal artery stenosis from various perspectives

    International Nuclear Information System (INIS)

    Helvoort-Postulart, Debby van; Dirksen, Carmen D.; Kessels, Alfons G.H.; Kroon, Abraham A.; Leeuw, Peter W. de; Nelemans, Patricia J.; Engelshoven, Jos M.A. van; Myriam Hunink, M.G.

    2006-01-01

    To determine the costs associated with the diagnostic work-up and percutaneous revascularization of renal artery stenosis from various perspectives. A prospective multicenter comparative study was conducted between 1998 and 2001. A total of 402 hypertensive patients with suspected renal artery stenosis were included. Costs were assessed of computed tomography angiography (CTA), magnetic resonance angiography (MRA), digital subtraction angiography (DSA), and percutaneous revascularization. From the societal perspective, DSA was the most costly (EUR 1,721) and CTA the least costly diagnostic technique (EUR 424). CTA was the least costly imaging procedure irrespective of the perspective used. The societal costs associated with percutaneous renal artery revascularization ranged from EUR 2,680 to EUR 6,172. Overall the radiology department incurred the largest proportion of the total societal costs. For the management of renal artery stenosis, performing the analysis from different perspectives leads to the same conclusion concerning the least costly diagnostic imaging and revascularization procedure. (orig.)

  12. Optimization of Ecg Gating in Quantitative Femoral Angiography

    International Nuclear Information System (INIS)

    Nilsson, S.; Berglund, I.; Erikson, U.; Johansson, J.; Walldius, G.

    2003-01-01

    Purpose: To determine which phase of the heart cycle would yield the highest reproducibility in measuring atherosclerosis-related variables such as arterial lumen volume and edge roughness. Material and Methods: 35 patients with hypercholesterolemia underwent select ive femoral angiography, repeated four times at 10-min intervals. The angiographies were performed with Ecg-gated exposures. In angiographies 1 and 2 the delay from R-wave maximum to each exposure was 0.1 s, in angiographies 3 and 4 the delay was 0.1, 0.3, 0.5 or 0.7 s or the exposures were performed 1/s without Ecg gating. Arterial lumen volume and edge roughness were measured in a 20-cm segment of the superficial femoral artery using a computer-based densitometric method. Measurement reproducibility was determined by comparing angiographies 1-2 and angiographies 3-4. Results: When measuring arterial lumen volume and edge roughness of a 20-cm segment of the femoral artery, reproducibility was not dependent on Ecg gating. In measuring single arterial diameters and cross-sectional areas, the reproducibility was better when exposures were made 0.1 s after the R-wave maximum than when using other settings of the Ecg gating device or without Ecg gating. Conclusion: The influence of pulsatile flow upon quantitative measurement in femoral angiograms seems to be the smallest possible in early systole, as can be demonstrated when measuring single diameters and cross-sectional areas. In variables based on integration over longer segments, measurement reproducibility seems to be independent of phase

  13. Optimization of Ecg Gating in Quantitative Femoral Angiography

    Energy Technology Data Exchange (ETDEWEB)

    Nilsson, S.; Berglund, I.; Erikson, U. [Univ. Hospital, Uppsala (Sweden). Dept. of Oncology, Radiology and Clinical Immunology; Johansson, J.; Walldius, G. [Karolinska Hospital, Stockholm (Sweden). King Gustav V Research Inst.

    2003-09-01

    Purpose: To determine which phase of the heart cycle would yield the highest reproducibility in measuring atherosclerosis-related variables such as arterial lumen volume and edge roughness. Material and Methods: 35 patients with hypercholesterolemia underwent select ive femoral angiography, repeated four times at 10-min intervals. The angiographies were performed with Ecg-gated exposures. In angiographies 1 and 2 the delay from R-wave maximum to each exposure was 0.1 s, in angiographies 3 and 4 the delay was 0.1, 0.3, 0.5 or 0.7 s or the exposures were performed 1/s without Ecg gating. Arterial lumen volume and edge roughness were measured in a 20-cm segment of the superficial femoral artery using a computer-based densitometric method. Measurement reproducibility was determined by comparing angiographies 1-2 and angiographies 3-4. Results: When measuring arterial lumen volume and edge roughness of a 20-cm segment of the femoral artery, reproducibility was not dependent on Ecg gating. In measuring single arterial diameters and cross-sectional areas, the reproducibility was better when exposures were made 0.1 s after the R-wave maximum than when using other settings of the Ecg gating device or without Ecg gating. Conclusion: The influence of pulsatile flow upon quantitative measurement in femoral angiograms seems to be the smallest possible in early systole, as can be demonstrated when measuring single diameters and cross-sectional areas. In variables based on integration over longer segments, measurement reproducibility seems to be independent of phase.

  14. Digital subtraction angiography in traumatology

    International Nuclear Information System (INIS)

    Steudel, A.; Harder, T.; Lackner, K.; Schneider, B.; Orellano, L.; Bonn Univ.; Bonn Univ.

    1986-01-01

    The methods, indications and results of digital subtraction angiography in traumatology are presented, based on 56 examinations. The different use of intravenous or intraarterial DSA will be discussed with respect to expanding and localisation of traumatic vascular injury. DSA is recommended as the method of choice for follow-up after vascular reconstructive procedure. (orig.) [de

  15. RENAL CRYOABLATION

    Directory of Open Access Journals (Sweden)

    A. V. Govorov

    2012-01-01

    Full Text Available Renal cryoablation is an alternative minimally-invasive method of treatment for localized renal cell carcinoma. The main advantages of this methodology include visualization of the tumor and the forming of "ice ball" in real time, fewer complications compared with other methods of treatment of renal cell carcinoma, as well as the possibility of conducting cryotherapy in patients with concomitant pathology. Compared with other ablative technologies cryoablation has a low rate of repeat sessions and good intermediate oncological results. The studies of long-term oncological and functional results of renal cryoablation are presently under way.

  16. Radiological diagnosis of hypernephromas in renal cysts or cystic kidneys

    International Nuclear Information System (INIS)

    Crone-Muenzebrock, W.; Brassow, F.

    1981-01-01

    The article presents the roentgenological results obtained in 12 patients with hypernephroma in a renal cyst or cystic kidneys, the hypernephroma having been identified surgically and histologically. The patients had been examined either vial IV pyelogram, sonography, computerized tomography and angiography, or with several of these methods. The renal tumor was identified with the help of sonography, computerized tomography and angiography in all cases. The IV pyelogram failed to produce a conclusive results in 2 cases. The space-occupying growth was wrongly assessed in respect of dignity because of the absence of solid tumor parts in 3 out of 5 cystic space-occupying growths via IV pyelogram, in 2 out of 4 cases via sonography and in 1 out of 4 cases via computerized tomography; these methods yielded the erroneous finding that the hypernephroma was a purely cystic space-occupying growth, whereas angiography yielded the correct diagnosis of the type of hypernephroma in 11 out of 12 patients. (orig.) [de

  17. The effect of L-cysteine on the portion-selective uptake of cadmium in the renal proximal tubule

    International Nuclear Information System (INIS)

    Murakami, Masataka; Sano, Kenichi; Webb, M.

    1987-01-01

    Cadmium (Cd), co-administered with an excess of L-cysteine, accumulates rapidly in the kidneys of the rat. After subcutaneous (s.c.) injection of 3 μmol CdCl 2 /kg body wt the concentrations of Cd in the blood and kidneys increase with the dose of cysteine over the range 0.06-5.0 mmol/kg body wt. At cysteine doses of less than 1.5 mmol/kg body wt the ratio of the concentrations of Cd in the outer medulla and cortex of the kidney remains the same as that after the injection of Cd alone. This ratio, however, is more than doubled at dose levels of 5-10 mmol cysteine/kg body wt. Hepatic uptake of Cd is unaffected by doses of cysteine below 1.5 mmol/kg body wt but decreases markedly at higher doses. In animals that are dosed simultaneously with 5 mmol cysteine/kg body wt, renal uptake of 109 Cd is known to occur in the straight segments of the proximal tubules. At a dose level of less than 1.5 mmol cysteine/kg body wt the present autoradiographical studies show that 109 Cd is taken up predominantly by the proximal convoluted tubules of the kidney cortex. At the critical dose level (1.5 mmol/kg body wt), cysteine decreases the retention of Cd at the s.c. injection site, but probably has little effect on the distribution of Cd between protein and other carrier molecules in the blood. This distribution, however, is altered at higher cysteine dose levels. It is suggested that, under the latter conditions, stable Cd-cysteine complexes are formed in the blood and are filtered readily through the glomeruli. These complexes are taken up in the kidney at the sites of cysteine reabsorption which, by studies with L-[ 35 S]-cysteine, are identified as the straight segments of the proximal tubules. (orig.)

  18. First-in-man-proof of concept study with molidustat: a novel selective oral HIF-prolyl hydroxylase inhibitor for the treatment of renal anaemia.

    Science.gov (United States)

    Böttcher, M; Lentini, S; Arens, E R; Kaiser, A; van der Mey, D; Thuss, U; Kubitza, D; Wensing, G

    2018-07-01

    Insufficient erythropoietin (EPO) synthesis is a relevant cause of renal anaemia in patients with chronic kidney disease. Molidustat, a selective hypoxia-inducible factor prolyl hydroxylase (HIF-PH) inhibitor, increases endogenous EPO levels dose dependently in preclinical models. We examined the pharmacokinetics, safety, tolerability and effect on EPO levels of single oral doses of molidustat in healthy male volunteers. This was a single-centre, randomized, single-blind, placebo-controlled, group-comparison, dose-escalation study. Molidustat was administered at doses of 5, 12.5, 25, 37.5 or 50 mg as a polyethylene glycol-based solution. In total, 45 volunteers received molidustat and 14 received placebo. Molidustat was absorbed rapidly, and the mean maximum plasma concentration and area under the concentration-time curve increased dose dependently. The mean terminal half-life was 4.64-10.40 h. A significant increase in endogenous EPO was observed following single oral doses of molidustat of 12.5 mg and above. Geometric mean peak EPO levels were 14.8 IU l -1 (90% confidence interval 13.0, 16.9) for volunteers who received placebo and 39.8 IU l -1 (90% confidence interval: 29.4, 53.8) for those who received molidustat 50 mg. The time course of EPO levels resembled the normal diurnal variation in EPO. Maximum EPO levels were observed approximately 12 h postdose and returned to baseline after approximately 24-48 h. All doses of molidustat were well tolerated and there were no significant changes in vital signs or laboratory safety parameters. Oral administration of molidustat to healthy volunteers elicited a dose-dependent increase in endogenous EPO. These results support the ongoing development of molidustat as a potential new treatment for patients with renal anaemia. © 2018 The British Pharmacological Society.

  19. Transapical aortic valve implantation without angiography: proof of concept.

    Science.gov (United States)

    Ferrari, Enrico; Sulzer, Christopher; Marcucci, Carlo; Rizzo, Elena; Tozzi, Piergiorgio; von Segesser, Ludwig K

    2010-06-01

    Cardiac computed tomographic scans, coronary angiograms, and aortographies are routinely performed in transcatheter heart valve therapies. Consequently, all patients are exposed to multiple contrast injections with a following risk of nephrotoxicity and postoperative renal failure. The transapical aortic valve implantation without angiography can prevent contrast-related complications. Between November 2008 and November 2009, 30 consecutive high-risk patients (16 female, 53.3%) underwent transapical aortic valve implantation without angiography. The landmarks identification, the stent-valve positioning, and the postoperative control were routinely performed under transesophageal echocardiogram and fluoroscopic visualization without contrast injections. Mean age was 80.1 +/- 8.7 years. Mean valve gradient, aortic orifice area, and ejection fraction were 60.3 +/- 20.9 mm Hg, 0.7 +/- 0.16 cm(2), and 0.526 +/- 0.128, respectively. Risk factors were pulmonary hypertension (60%), peripheral vascular disease (70%), chronic pulmonary disease (50%), previous cardiac surgery (13.3%), and chronic renal insufficiency (40%) (mean blood creatinine and urea levels: 96.8 +/- 54 microg/dL and 8.45 +/- 5.15 mmol/L). Average European System for Cardiac Operative Risk Evaluation was 32.2 +/- 13.3%. Valve deployment in the ideal landing zone was 96.7% successful and valve embolization occurred once. Thirty-day mortality was 10% (3 patients). Causes of death were the following: intraoperative ventricular rupture (conversion to sternotomy), right ventricular failure, and bilateral pneumonia. Stroke occurred in one patient at postoperative day 9. Renal failure (postoperative mean blood creatinine and urea levels: 91.1 +/- 66.8 microg/dL and 7.27 +/- 3.45 mmol/L), myocardial infarction, and atrioventricular block were not detected. Transapical aortic valve implantation without angiography requires a short learning curve and can be performed routinely by experienced teams. Our report

  20. Clinical application of electron beam computed tomography in intravenous three-dimensional coronary angiography

    International Nuclear Information System (INIS)

    Luo Chufan; Du Zhimin; Hu Chengheng; Li Yi; Zeng Wutao; Ma Hong; Li Xiangmin; Zhou Xuhui

    2002-01-01

    Objective: To investigate the clinical application of intravenous three-dimensional coronary angiography using electron beam computed tomography (EBCT) as compared with selective coronary angiography. Methods: Intravenous EBCT and selective coronary angiography were performed during the same period in 38 patients. The value of EBCT angiography for diagnosing coronary artery disease was evaluated. Results: The number of coronary arteries adequately evaluated by EBCT angiography was 134 out of 152 vessels (88.2%), including 100% of the left main coronary arteries, 94.7% of the left anterior descending arteries, 81.6% of the left circumflex arteries and 76.3 % of the right coronary arteries. Significantly more left main and heft anterior descending coronary arteries were adequately visualized than the left circumflex and right coronary arteries (P < 0.05). The sensitivity, specificity, accuracy, and positive and negative predictive value of EBCT angiography for diagnosing coronary artery disease were 88.0%, 84.6%, 86.8%, 91.7% and 78.6%, respectively. Of the 38 arteries with ≥ 50% stenosis, EBCT underestimated 8, for a sensitivity of 78.9%. Of the 96 arteries without significant stenosis, EBCT overestimated 7 stenosis, for a specificity of 92.7%. Conclusion: Intravenous electron beam computed tomographic coronary angiography is a promising noninvasive method for diagnosing coronary artery disease

  1. Noninvasive method using multidetector CT for calculating the relative blood supply ratio of duplicated renal arteries in renal donors

    International Nuclear Information System (INIS)

    Kuwabara, Masatomo; Kim, Tonsok; Nakamura, Hironobu; Narumi, Yoshifumi; Takahashi, Satoru; Sato, Yoshinobu; Murakami, Takamichi

    2006-01-01

    The aim of this study was to evaluate the correlation between the renal artery cross-sectional area measured by multidetector computed tomography (MDCT) and the nephrogram area calculated by renal arteriography in potential living renal donors with duplicated renal arteries. Medical records of 18 patients with duplicated renal arteries who underwent both MDCT angiography and renal arteriography between 2001 and 2003 were retrospectively reviewed. All 20 kidneys were evaluated. Renal artery cross-sectional areas were measured using the workstation to which the CT data were transferred; the nephrogram areas on the digitized angiographic images were calculated using public domain software. Bland-Altman analysis was performed to compare the cross-sectional area ratio of the accessory arteries to the main renal arteries, with the ratios obtained from the nephrogram areas calculated from the arteriograms. The mean cross-sectional areas of the accessory and main renal arteries were 6.78 and 20.9 mm 2 , respectively. The ratio of the nephrogram areas calculated from the arteriograms ranged from 0.094 to 0.809. Bland-Altman analysis showed no significant difference. It is possible to predict the supply volume of accessory renal arteries by measuring the cross-sectional area of the accessory and main renal arteries in potential living renal donors. (author)

  2. Use of multidetector computed tomography angiography of upper limb circulation in patients undergoing coronary artery bypass grafting surgery

    Directory of Open Access Journals (Sweden)

    Hasan B Altinsoy

    2017-01-01

    Full Text Available Objective: This study aimed to evaluate the bilateral forehand circulation using a 64-channel multidetector computed tomography (MDCT as a noninvasive method to define criteria for an upper extremity arterial anatomy and pathology prior to the use of arterial conduits. Materials and Methods: Fifty-five patients with coronary artery disease who underwent total arterial coronary artery bypass grafting (CABG were randomly selected for this prospective study. MDCT angiography was performed for 110 examinations of forearm and hand arterial anatomy. Prior to MDCT, Allen tests were performed in all patients with a normal result, except four. Thirteen patients had diabetes mellitus (DM, 8 had peripheral artery occlusive disease, and 19 had a history of smoking. Results: All arteries, including axillary, ulnar artery (UA and radial artery (RA, were clearly visualized in all patients. Upper extremity anatomical and pathological results were examined in 16 patients (29.1%. Severely calcified RA and/or UA were found in 6 patients who had a moderate renal failure. Nearly total occlusion of the RA was detected in another two patients. Focal intimal RA calcification was recorded in 1 female and 3 male patients. Ten patients who had severe calcification or intimal sclerosis of the upper extremity arteries had DM. The remaining patients had normal forehand arterial circulation. A persistent median artery with the absence of radial and ulnar arteries and a high bifurcation of RA from the brachial artery was detected as an anatomic variation in seven patients (12.7%. Conclusions: The major advantages of MDCT angiography are its non-invasiveness and the ability to detect calcific subadventitial plaques, which are difficult to diagnose using conventional angiography. MDCT may be used as a safe and non-invasive method to assess RA and UA prior to harvesting the upper limb artery. Preoperative imaging of forehand arteries is a means to avoid unnecessary forearm

  3. MR angiography in the evaluation of a renovascular cause of neonatal hypertension

    International Nuclear Information System (INIS)

    Mustafa, Amira E.; Valentini, Rudolph P.; Mattoo, Tej K.; Bloom, David A.; Imam, Abubakr A.

    2006-01-01

    Neonatal hypertension occurs in 2% of all infants and it is caused by renovascular abnormalities in 70% of these infants. The gold standard for diagnosing renovascular disease is conventional renal angiography. However, in neonates the procedure is not commonly used because of its invasive and technically challenging nature. MRI and MR angiography (MRA) are less invasive yet reliable means of detecting renovascular disease in adults. There is minimal literature on the use of MRI/MRA in neonatal hypertension. We report a neonate with hypertension secondary to a renovascular abnormality in which MRI/MRA was helpful in uncovering segmental renal artery stenosis. The infant underwent partial nephrectomy with subsequent resolution of his hypertension. Further studies are needed to validate the use of MRI/MRA in the evaluation of neonatal hypertension. (orig.)

  4. Renal cancer.

    NARCIS (Netherlands)

    Corgna, E.; Betti, M.; Gatta, G.; Roila, F.; Mulder, P.H.M. de

    2007-01-01

    In Europe, renal cancer (that is neoplasia of the kidney, renal pelvis or ureter (ICD-9 189 and ICD-10 C64-C66)) ranks as the seventh most common malignancy in men amongst whom there are 29,600 new cases each year (3.5% of all cancers). Tobacco, obesity and a diet poor in vegetables are all

  5. Renal cancer

    NARCIS (Netherlands)

    Corgna, Enrichetta; Betti, Maura; Gatta, Gemma; Roila, Fausto; De Mulder, Pieter H. M.

    2007-01-01

    In Europe, renal cancer (that is neoplasia of the kidney, renal pelvis or ureter (ICD-9 189 and ICD-10 C64-C66)) ranks as the seventh most common malignancy in men amongst whom there are 29,600 new cases each year (3.5% of all cancers). Tobacco, obesity and a diet poor in vegetables are all

  6. Salvage of bilateral renal artery occlusion after endovascular aneurysm repair with open splenorenal bypass

    Directory of Open Access Journals (Sweden)

    Samuel Jessula, MDCM

    2017-09-01

    Full Text Available We report renal salvage maneuvers after accidental bilateral renal artery coverage during endovascular aneurysm repair of an infrarenal abdominal aortic aneurysm. A 79-year-old man with an infrarenal abdominal aortic aneurysm was treated with endovascular aneurysm repair. Completion angiography demonstrated coverage of the renal arteries. Several revascularization techniques were attempted, including endograft repositioning and endovascular stenting through the femoral and brachial approach. The patient eventually underwent open splenorenal bypass with a Y Gore-Tex graft (W. L. Gore & Associates, Flagstaff, Ariz. After 3 months, computed tomography showed no evidence of endoleak and patent renal arteries. Renal function was well maintained, and the patient did not require dialysis.

  7. Impact of computerized order entry and pre-mixed dialysis solutions for continuous veno-venous hemodiafiltration on selection of therapy for acute renal failure.

    Science.gov (United States)

    Saadulla, Lawand; Reeves, W Brian; Irey, Brittany; Ghahramani, Nasrollah

    2012-02-01

    To investigate the impacts of availability of pre-mixed solutions and computerized order entry on nephrologists' choice of the initial mode of renal replacement therapy in acute renal failure. We studied 898 patients with acute renal failure in 3 consecutive eras: era 1 (custom-mixed solution; n = 309), era 2 (pre-mixed commercial solution; n = 324), and era 3 (post-computerized order entry; n = 265). The proportion of patients treated with renal replacement therapy and the time from consult to initiation of continuous renal replacement therapy was similar in the 3 eras. Following introduction of the pre-mixed solution, the proportion of patients treated with continuous renal replacement therapy increased (20% vs. 33%; p mixed solution increases the likelihood of initiating continuous renal replacement therapy in acute renal failure, initiating it at a lower creatinine and for older patients, use of continuous veno-venous hemodialysis and higher prescribed continuous renal replacement therapy dose. Computerized order entry implementation is associated with an additional increase in the use of continuous veno-venous hemodialysis, higher total prescribed dialysis dose, and use of CRRT among an increasing number of patients not on mechanical ventilation. The effect of these changes on patient survival is not significant.

  8. Renal PTA stenting

    International Nuclear Information System (INIS)

    Tsetis, D.

    2012-01-01

    Full text: Renal artery stenosis (RAS) is a common condition that may lead to hypertension, progressive renal dysfunction and cardiovascular morbidity. Catheter-based therapy for symptomatic, haemodynamically significant, RAS has become the preferred method of revascularization. Balloon angioplasty has been the traditional treatment of choice for fibromuscular dysplasia, however stents are increasingly used for the treatment of atheromatous lesions; in many cases-such as in ostial lesions-, direct stenting is strongly indicated. Despite the increased use of endovascular therapy for renal artery stenosis, there is still controversy regarding the optimal management and the net benefit of this treatment. Several randomized trials of balloon angioplasty or stenting for renal artery stenosis compared with medical therapy alone have been conducted, however these could not show definite advantage of endovascular therapy. Problems encountered with those trials include enrollment of small number of patients, frequent crossover from medical to interventional therapy compromising the intention-to-treat results, or selection of patients that are not expected to show clear benefit. The Angioplasty and Stenting for Renal Artery Lesions (ASTRAL) is the most important of these trials; however, it,s study design was faulty and therefore did not provide conclusive evidence to answer the question of whether angioplasty and stenting or medical therapy is the best treatment for haemodynamically significant RAS. All expectations are now focused on the Cardiovascular Outcomes in Renal Atherosclerotic Lesions (CORAL) trial which was designed to answer the same question, and its methodologies took into consideration the weaknesses of the ASTRAL trial. Regarding stent device itself, it seems that the optimal design is probably a stainless steel, laser cut, open-cells stent mounted on a rapid exchange delivery balloon catheter compatible with 0.014-in and 0.018-in guidewire. As a future

  9. Is fasting necessary for elective cerebral angiography?

    Science.gov (United States)

    Kwon, O-K; Oh, C W; Park, H; Bang, J S; Bae, H-J; Han, M K; Park, S-H; Han, M H; Kang, H-S; Park, S-K; Whang, G; Kim, B-C; Jin, S-C

    2011-05-01

    In order to prevent unexpected events such as aspiration pneumonia, cerebral angiography has been performed under fasting in most cases. We investigated prospectively the necessity of fasting before elective cerebral angiography. The study is an open-labeled clinical trial without random allocation. In total, 2554 patients who underwent elective cerebral angiography were evaluated on development of nausea, vomiting, and pulmonary aspiration during and after angiography. Potential risks and benefits associated with fasting were provided in written documents and through personal counseling to patients before the procedure. The patients chose their fasting or nonfasting option. No restriction in diet was given after angiography. The patients were observed for 24 hours. Nausea and vomiting during and within 1 hour after angiography was considered as a positive event associated with cerebral angiography. The overall incidence of nausea and vomiting during and within 1 hour after angiography was 1.05% (27/2554 patients). There was no patient with pulmonary aspiration. No statistical difference in nausea and vomiting development between the fasting and the diet groups was found. The incidence of nausea and vomiting associated with cerebral angiography is low and not affected by diet or fasting. Pulmonary aspiration had no difference between the diet and the fasting group. Our study suggests that fasting may not be necessary for patients who undergo elective cerebral angiography.

  10. Evidence of changes in renal charge selectivity in patients with type 1 (insulin-dependent) diabetes mellitus

    DEFF Research Database (Denmark)

    Kverneland, A; Feldt-Rasmussen, B; Vidal, P

    1986-01-01

    in plasma and urine was determined by a specific, sensitive and highly reproducible chromatographic procedure. In diabetic patients with normal urinary albumin excretion, the selectivity index was increased three-fold compared with that of non-diabetic subjects (2 p less than 0.01). A significant...... clearance of non-glycated plasma albumin/clearance of glycated plasma albumin in 38 patients with Type 1 diabetes mellitus. The two albumin molecules differed slightly in charge, non-enzymatic glycated albumin being more anionic at physiological pH compared with unmodified plasma albumin. Glycated albumin...... patients with increased albumin excretion rate had a significantly lower selectivity index compared with patients with normal albumin excretion (2 p less than 0.01). A significant negative correlation (r = 0.85, 2 p less than 0.001, exponential curve fit) was seen between urinary albumin excretion...

  11. Interventional therapy of atherosclerotic renal artery occlusion

    International Nuclear Information System (INIS)

    Li Jian; Xu Ke; Xiao Liang

    2009-01-01

    Objective: To investigate the effectiveness of interventional therapy for the atherosclerotic renal artery occlusion (ARAO). Methods: During the period of June 2001-Dec. 2007, 16 patients with ARAO (total of 16 occluded arteries) underwent interventional managements, including percutaneous endovascular renal artery revascularization, balloon dilatation angioplasty and stent placement. Follow-up survey was made at regular intervals. The patent condition of the renal artery was evaluated with ultrasonography and digital subtraction angiography. The blood pressure and the renal function were determined and the data were statistically analyzed in order to assess the intermediate and long-term effect of the interventional therapy. Results: Of 16 patients, technical success was achieved in 15 (93.8%) and failure occurred in one. During a follow-up period of 9 - 24 months, 3 patients died. According to the data obtained at each patient's last follow-up survey, the hypertension fell to normal in 3 (25.0%), was improved in 7 (58.3%) and showed no marked change in 2 patients (16.7%), with a clinical efficacy of 83.3% (10 / 12). The renal function was improved in 2 (16.7%), stabilized in 6 (50%) and deteriorated in 4 patients (33.3%), with an effective rate of 66.7% (8 / 12). Conclusion: For the treatment of atherosclerotic renal artery occlusion, the interventional therapy carries high successful rate and can effectively lower the blood pressure level, in addition, it can also protect the renal function in a certain degree. (authors)

  12. Rapid line scan MR angiography

    International Nuclear Information System (INIS)

    Frahm, J.; Merboldt, K.D.; Hanicke, W.; Bruhn, H.

    1987-01-01

    Direct MR angiography may be performed using line scan imaging techniques combined with presaturation of stationary spins. Thus, a single line scan echo yields a projection of vessels due to the signal from reflowing unsaturated spins. Reconstruction of an angiographic image is performed line by line at slightly incremented positions. In particular, line scan angiography is direct and fast without a sensitivity to artifacts even for high flow rates. Image resolution and field of view may be chosen without restrictions, and zoom images using enhanced gradients may be recorded without aliasing artifacts. The method is robust with respect to eddy currents and pulsatile flow. Line scan MR angiograms of phantoms, animals, and human volunteers have been recorded using 90 0 radio frequency pulses and gradient-recalled echoes

  13. Electrocardiographically gated snapshot MR angiography

    International Nuclear Information System (INIS)

    Brown, D.G.; Holsinger, A.E.; Riederer, S.J.

    1990-01-01

    The purpose of this paper is to evaluate the effectiveness of applying ultrashort (∼12 msec) TR times and measuring the central phase encodings first in improving the accuracy of vascular depiction in MR angiography. The imaging method combines ultrashort TR imaging techniques with time-of-flight MR angiography. The central phase-encoding views are acquired first, and an inversion-recovery contrast preparation pulse is applied prior to image acquisition to null signal from static tissues. In initial studies, the method was tested on phantoms and volunteers. The contrast-preparation phase effectively nulls static spins at the start of image acquisition. During the TL period fresh blood flows into the imaging section; even slowly moving blood is fully replaced

  14. Contrast-enhanced MR angiography

    International Nuclear Information System (INIS)

    Bosmans, H.; Marchal, G.

    1996-01-01

    Despite many optimizations, the current limitations of plain MR angiography include: Saturation that impairs the visualization of veins and arteries with slow flow and spin-dephasing signal voids in locations with turbulent flow. Recently, the use of contrast agents has been proposed to cope with these remaining problems. Because of induced shortening of the T1 of the blood, saturation in the blood vessels is overcome. As a result, arteries and veins are visualized with the same signal intensity, which makes the technique less flow-dependent. In combination with short T1-weighted acquisitions, today CE MRA can be obtained while the patient is holding his breath. This last approach is most promising for abdominal applications since the respiratory motion can be frozen. As these acquisitions also use very short echo times, spin dephasing can be reduced. In conclusion, the use of contrast agents has greatly increased the clinical usefulness of MR angiography. (orig.) [de

  15. Pulmonary angiography with lopamidol 370

    International Nuclear Information System (INIS)

    Braun, S.D.; Saeed, M.; Perlmutt, L.M.; Newman, G.E.; Illescas, F.F.; Cohan, R.H.; Dunnick, N.R.

    1986-01-01

    Fifty-one consecutive patients who underwent pulmonary angiography with iopamidol, 370 mg/ml, were studied prospectively. Patients were asked to grade any heat or pain felt on injection, and were observed for coughing. Right atrial and pulmonary artery pressures were obtained before the first and after the final contrast agent injection. Pressure changes were compared with those in a consecutive group of 25 patients who underwent examinations performed with Na-meglumine diatrizoate, 370 mg/ml. Film quality was evaluated for patient motion. Iopamidol generated marked discomfort in only three patients. Pressure changes were largely unremarkable. In no case was there any significant motion artifact secondary to coughing. Iopamidol is a safe, well-tolerated contrast agent for pulmonary angiography. It improves image quality by nearly eliminating coughing

  16. New aspects in the diagnosis of angina abdominalis using digital substraction angiography

    International Nuclear Information System (INIS)

    Mahmalat, M.O.; Beyer, H.K.

    1985-01-01

    Selective intra-arterial digital substraction angiography (DSA) is important in the demonstration of the visceral abdominal vessels in angina-abdominalis patients. DSA allows to accurately determine the location of stenoses, vascular occlusions or plaque formations as does conventional angiography; in addition, it provides for simultaneous direct observation which is a major advantage over the conventional technique since suspected lesions can be better focussed in several planes. (orig.) [de

  17. Renal scintigraphy with captopril for the investigation of arterial hypertension

    International Nuclear Information System (INIS)

    Nitzsche, E.; Strauss, E.; Moser, E.; Grosser, G.; Sankt Marienkrankenhaus, Frankfurt am Main; Rump, C.; Keller, E.; Meyer, E.

    1991-01-01

    Renal artery stenosis (RAS) is a rare cause of hypertension. Radiological tests can disclose the morphological changes, but not their functional effect on renal function and perfusion. Normalization of the blood pressure can be achieved by intervention (operation, percutaneous transluminal renal angiography; PTRA), in cases of prolonged RAS-induced hypertension long-term preservation of the organ function is most important. The purpose of this study was the validation of captopril renography as a screening test for hypertension secondary to RAS prior to PTRA. Captopril renography with 99m Tc-MAG 3 has a high sensitivity (94%) and acceptable specificity (88%) for the screening of hypertensive patients. The positive predictive value is 74% and the negative predictive value 98%, compared with the 'gold standard' of angiography. (orig.) [de

  18. Evaluation of resectability of renal cell carcinoma by computed tomography

    International Nuclear Information System (INIS)

    Hiramatsu, Yoshihiro; Matsumoto, Kunihiko; Tatezawa, Takashi; Kikuchi, Yoichi; Akisada, Masahiro; Kitagawa, Ryuichi

    1982-01-01

    Renal cell carcinoma is one of the unique neoplasm which is characterized by disappearing of the metastatic tumors after removal of the primary lesion. Angiography has been performed to evaluate the resectability of the primary tumor by nephrectomy in the past. With the use of computed tomography, detailed evaluation of the retroperitoneal structures is now possible. We have evaluated the resectability of renal cell tumor by computed tomography and compared the results with the angiographic findings and operative findings. Computed tomography is very accurate in determining the extent of the tumor especially in evaluation of tumor and the Gerota's fascia, which is essential to determine the resectability of the tumor. Informations about lymph node metastasis and invasion to the renal veins or inferior vena cava are also obtained.FIn most of the cases, angiography can be spared if computed tomography is properly performed. (author)

  19. Present rank of angiography within complex tumor diagnosis

    International Nuclear Information System (INIS)

    Waigand, J.

    1990-01-01

    The development of noninvasive imaging methods with high diagnostic accuracy in the last decade has led to a new determination of the role of angiographic techniques in oncologic diagnosis. The disadvantages of angiography are discussed and the major indications in tumor diagnosis are delineated: preoperative vascular mapping, vascular involvement of the great vessels, CT and ultrasound equivocal, selective blood sampling and interventional procedures. The increasing importance of interventional radiology in oncology is emphasized. (author)

  20. Renal scan

    Science.gov (United States)

    ... this page: //medlineplus.gov/ency/article/003790.htm Renal scan To use the sharing features on this ... anaphylaxis . Alternative Names Renogram; Kidney scan Images Kidney anatomy Kidney - blood and urine flow References Chernecky CC, ...

  1. Digital subtraction angiography in ischemic cerebrovascular accidents

    Energy Technology Data Exchange (ETDEWEB)

    Manelfe, C.; Bonafe, A.; Ducos de Lahitte, M.; Rascol, A.; Prere, J.; Guiraud, B.; Marc-Vergnes, J.P. (Hopital Purpan, 31 - Toulouse (France))

    1983-12-29

    Recent advances in computer and radiological technology have permitted reassessment of intravenous angiography in the evaluation of cerebrovascular disorders. Although digital subtraction angiography is a relatively new technique, it has rapidly gained a widespread acceptance. It has extended the use of angiography to outpatients and to people in whom conventional angiography is contraindicated. This reliable, safe, and relatively noninvasive technique offers the user two benefits: real-time subtraction and enhanced image quality. The system allows angiographic evaluation of the extracranial and intracranial vessels by means of intravenous injection of contrast material. Extracranial studies clearly demonstrate stenoses and occlusions of the major cervicocephalic arteries. Intracranial studies usually detect major cerebrovascular occlusions and provide insight into the collateral flow patterns. Intravenous digital subtraction angiography permits accurate assessment of cervicocephalic vessels after surgical repair. Although intravenous digital subtraction angiography obviates the need for conventional angiography in many cases, movements from the patients, or superimposition of vascular structures can substantially degrade the quality of the images. Digital subtraction angiography with intra-arterial injection of contrast medium will be contemplated in patients with poor intravenous digital subtraction angiography studies prior to surgery.

  2. Digital subtraction angiography in ischemic cerebrovascular accidents

    International Nuclear Information System (INIS)

    Manelfe, C.; Bonafe, A.; Ducos de Lahitte, M.; Rascol, A.; Prere, J.; Guiraud, B.; Marc-Vergnes, J.P.

    1983-01-01

    Recent advances in computer and radiological technology have permitted reassessment of intravenous angiography in the evaluation of cerebrovascular disorders. Although digital subtraction angiography is a relatively new technique, it has rapidly gained a widespread acceptance. It has extended the use of angiography to outpatients and to people in whom conventional angiography is contraindicated. This reliable, safe, and relatively noninvasive technique offers the user two benefits: real-time subtraction and enhanced image quality. The system allows angiographic evaluation of the extracranial and intracranial vessels by means of intravenous injection of contrast material. Extracranial studies clearly demonstrate stenoses and occlusions of the major cervicocephalic arteries. Intracranial studies usually detect major cerebrovascular occlusions and provide insight into the collateral flow patterns. Intravenous digital subtraction angiography permits accurate assessment of cervicocephalic vessels after surgical repair. Although intravenous digital subtraction angiography obviates the need for conventional angiography in many cases, movements from the patients, or superimposition of vascular structures can substantially degrade the quality of the images. Digital subtraction angiography with intra-arterial injection of contrast medium will be contemplated in patients with poor intravenous digital subtraction angiography studies prior to surgery [fr

  3. Hemifacial spasm; The value of vertebral angiography

    International Nuclear Information System (INIS)

    Yang, Hak Seok; Kim, Myung Soon; Han, Yong Pyo

    1992-01-01

    In order to evaluate the value of vertebral angiography in assesment of hemifacial spasm, We reviewed retrospectively the vertebral angiography of 28 patients (30 cases) with surgically proved hemifacial spasm but normal CT scans of posterior fossa. There were 9 males and 19 females. Angiography revealed vascular focus of hemifacial spasm located at anterior inferior cerebellar artery , posterior inferior cerebellar artery, and vertebral artery in 19, 9, and 2 cases respectively. Right side was involved in 20 cases. All involved vessels were elongated, tortuous, and dilated. In conclusion, vertebral angiography was valuable in evaluating hemifacial spasm of vascular origin in the posterior fossa

  4. Clinical Assessment of a New Stereoscopic Digital Angiography System

    International Nuclear Information System (INIS)

    Moll, Thierry; Douek, Philippe; Finet, Gerard; Turjman, Francis; Picard, Catherine; Revel, Didier; Amiel, Michel

    1998-01-01

    Purpose: To assess the clinical feasibility of an experimental modified angiographic system capable of real-time digital stereofluoroscopy and stereography in X-ray angiography, using a twin-focus tube and a stereoscopic monitor. Methods: We report the experience obtained in 37 patients with a well-documented examination. The patients were examined for coronary angiography (11 cases), aortography (7 cases), pulmonary angiography (6 cases), inferior vena cava filter placement (2 cases), and cerebral angiography (11 cases). Six radiologists were asked to use stereoscopic features for fluoroscopy and angiography. A questionnaire was designed to record their subjective evaluation of stereoscopic image quality, ergonomics of the system, and its medical interest. Results: Stereofluoroscopy was successfully used in 25 of 37 cases; diplopia and/or ghost images were reported in 6 cases. It was helpful for aortic catheterization in 10 cases and for selective catheterization in 5 cases. In stereoangiography, depth was easily and accurately perceived in 27 of 37 cases; diplopia and/or ghost images were reported in 4 cases. A certain gain in the three-dimensional evaluation of the anatomy and relation between vessels and lesions was noted. As regards ergonomic considerations, polarized spectacles were not considered cumbersome. Visual fatigue and additional work were variously reported. Stereoshift tuning before X-ray acquisition was not judged to be a limiting factor. Conclusion: A twin-focus X-ray tube and a polarized shutter for stereoscopic display allowed effective real-time three-dimensional perception of angiographic images. Our clinical study suggests no clear medical interest for diagnostic examinations, but the field of interventional radiology needs to be investigated

  5. Renal Hemangiopericytoma

    Directory of Open Access Journals (Sweden)

    İbrahim Halil Bozkurt

    2015-03-01

    Full Text Available Hemangiopericytoma is an uncommon perivascular tumor originating from pericytes in the pelvis, head and tneck, and the meninges; extremely rarely in the urinary system. We report a case of incidentally detected renal mass in which radiologic evaluation was suggestive of renal cell carcinoma. First, we performed partial nephrectomy, and then, radical nephrectomy because of positive surgical margins and the pathological examination of the surgical specimen that revealed a hemangiopericytoma. No additional treatment was administered.

  6. Rare variations in renal anatomy and blood supply: CT appearances and embryological background. A pictorial essay

    International Nuclear Information System (INIS)

    Cocheteux, B.; Gaxotte, V.; Beregi, J.P.; Mounier-Vehier, C.; McFadden, E.P.; Francke, J.P.

    2001-01-01

    Helical CT angiography is increasingly used for the evaluation of the kidneys and the renal vessels. Knowledge of the potential variants in renal and renal vascular anatomy and of their appearances on helical CT are thus indispensable for radiologists who perform and interpret such examinations. We report six cases of anatomic variants that we encountered in our tertiary referral centre over the past 5 years, during which time we have performed 4850 helical CT angiograms, including 1432 renal artery examinations. These represent rarer anomalies in renal vascularization, most of which were associated with renal malformations (horseshoe kidney with or without cortical torsion, renal malrotation, single kidney, and thoracic origin of a renal artery). We present the helical CT findings and discuss the possible embryological mechanisms and the practical implications of these abnormalities for the radiologist. (orig.)

  7. Rare variations in renal anatomy and blood supply: CT appearances and embryological background. A pictorial essay

    Energy Technology Data Exchange (ETDEWEB)

    Cocheteux, B.; Gaxotte, V.; Beregi, J.P. [Dept. of Vascular Radiology, Hopital Cardiologique, CHRU de Lille (France); Mounier-Vehier, C. [Service d' Hypertension Arterielle et Medecine Interne, Hopital Cardiologique, CHRU de Lille (France); McFadden, E.P. [Service de Cardiologie B, Hopital Cardiologique, CHRU de Lille (France); Francke, J.P. [Lab. d' Anatomie, Faculte de Medecine, Lille (France)

    2001-05-01

    Helical CT angiography is increasingly used for the evaluation of the kidneys and the renal vessels. Knowledge of the potential variants in renal and renal vascular anatomy and of their appearances on helical CT are thus indispensable for radiologists who perform and interpret such examinations. We report six cases of anatomic variants that we encountered in our tertiary referral centre over the past 5 years, during which time we have performed 4850 helical CT angiograms, including 1432 renal artery examinations. These represent rarer anomalies in renal vascularization, most of which were associated with renal malformations (horseshoe kidney with or without cortical torsion, renal malrotation, single kidney, and thoracic origin of a renal artery). We present the helical CT findings and discuss the possible embryological mechanisms and the practical implications of these abnormalities for the radiologist. (orig.)

  8. Large Renal Artery Aneurysm Treated with Guglielmi Detachable Coils: Procedural and 4-Year Follow-up Results

    International Nuclear Information System (INIS)

    Damascelli, Bruno; Bartorelli, Antonio L.; Ticha, Vladimira; Trabattoni, Daniela; Lanocita, Rodolfo

    2008-01-01

    A large aneurysm of the left renal artery was found incidentally during abdominal ultrasound in a 39-year-old woman with no medical or family history of cardiovascular disease. Vascular pathology with a dysplastic appearance was confirmed by magnetic resonance angiography and the patient was offered transcatheter embolization. Since the position and size of the neck of the aneurysm could not be determined at angiography, detachable platinum coils were used for occlusion. The procedure was performed without complications. During a 4-year follow-up no alterations of renal function, recanalization of the aneurysm, or perfusion defects in the rest of the left renal circulation were noted.

  9. [Myocardial perfusion imaging by digital subtraction angiography].

    Science.gov (United States)

    Kadowaki, H; Ishikawa, K; Ogai, T; Katori, R

    1986-03-01

    Several methods of digital subtraction angiography (DSA) were compared to determine which could better visualize regional myocardial perfusion using coronary angiography in seven patients with myocardial infarction, two with angina pectoris and five with normal coronary arteries. Satisfactory DSA was judged to be achieved if the shape of the heart on the mask film was identical to that on the live film and if both films were exactly superimposed. To obtain an identical mask film in the shape of each live film, both films were selected from the following three phases of the cardiac cycle; at the R wave of the electrocardiogram, 100 msec before the R wave, and 200 msec before the R wave. The last two were superior for obtaining mask and live films which were similar in shape, because the cardiac motion in these phases was relatively small. Using these mask and live films, DSA was performed either with the continuous image mode (CI mode) or the time interval difference mode (TID mode). The overall perfusion of contrast medium through the artery to the vein was adequately visualized using the CI mode. Passage of contrast medium through the artery, capillary and vein was visualized at each phase using TID mode. Subtracted images were displayed and photographed, and the density of the contrast medium was adequate to display contour lines as in a relief map. Using this DSA, it was found that regional perfusion of the contrast medium was not always uniform in normal subjects, depending on the typography of the coronary artery.(ABSTRACT TRUNCATED AT 250 WORDS)

  10. Interventional treatment of arterial complications in post renal transplantation

    International Nuclear Information System (INIS)

    Qian Xiaojun; Dai Dingke; Zhai Renyou

    2004-01-01

    Objective: To report our experience of interventional procedure for arterial complications in post renal transplantation and to evaluate its clinical value. Methods: In a retrospective analysis of renal transplantations in our center, 52 cases of renal allograft artery abnormalities had taken angiography. Interventional procedure included transluminal angioplasty of arterial stenoses, treatment of arterial occlusion, and embolization of pseudoaneurysm. Results: Renal allograft artery abnormalities included artery stenosis (n=21), artery thrombosis (n=13) and embolision (n=1), renal artery pseudoaneurysms (n=2), and decrease of renal artery flow (n=3). Of the 21 artery stenosis, 2 grafts with artery stenosis were lost because the stenosis could not be corrected, and 3 with mild stenosis received no treatment. Another 16 accepted renal artery angioplasty (balloon dilation, n=12, and stent implantation, n=4). 14 achieved long-term allograft function. 1 graft was lost because renal function failed to recover. Restenosis occurred in one stent implantation, and lost the allograft function after secondary dilation. 13 cases received thrombolytic therapy through artery catheter for thrombosis and 9 achieved long-term allograft function. Thrombolyses failed in 3 cases, and renal function failed to recover in 1 case. One pseudoaneurysm received stent implantation after embolization, and got a short-term allograft function. The other one received allograft excision. Conclusion: Intravascular interventional therapy will be the first-line therapy for any indications of complication in post renal transplantation, and it can surely save the kidney in a majority of instances. (authors)

  11. Diagnosis of myocardial ischemia combining multiphase postmortem CT-angiography, histology, and postmortem biochemistry.

    Science.gov (United States)

    Vanhaebost, Jessica; Ducrot, Kewin; de Froidmont, Sébastien; Scarpelli, Maria Pia; Egger, Coraline; Baumann, Pia; Schmit, Gregory; Grabherr, Silke; Palmiere, Cristian

    2017-02-01

    The aim of this study was to assess whether the identification of pathological myocardial enhancement at multiphase postmortem computed tomography angiography was correlated with increased levels of troponin T and I in postmortem serum from femoral blood as well as morphological findings of myocardial ischemia. We further aimed to investigate whether autopsy cases characterized by increased troponin T and I concentrations as well as morphological findings of myocardial ischemia were also characterized by pathological myocardial enhancement at multiphase postmortem computed tomography angiography. Two different approaches were used. In one, 40 forensic autopsy cases that had pathological enhancement of the myocardium (mean Hounsfield units ≥95) observed at postmortem angiography were retrospectively selected. In the second approach, 40 forensic autopsy cases that had a cause of death attributed to acute myocardial ischemia were retrospectively selected. The preliminary results seem to indicate that the identification of a pathological enhancement of the myocardium at postmortem angiography is associated with the presence of increased levels of cardiac troponins in postmortem serum and morphological findings of ischemia. Analogously, a pathological enhancement of the myocardium at postmortem angiography can be retrospectively found in the great majority of autopsy cases characterized by increased cardiac troponin levels in postmortem serum and morphological findings of myocardial ischemia. Multiphase postmortem computed tomography angiography is a useful tool in the postmortem setting for investigating ischemically damaged myocardium.

  12. Endovascular treatment of renal artery stenoses

    International Nuclear Information System (INIS)

    Lashari, M.N.

    2015-01-01

    To evaluate the procedure success and effect on hypertension after stenting of incidentally diagnosed atherosclerotic renal artery stenoses. Study Design: An experimental study. Place and Duration of Study: A multicentric study was conducted at the Plastic Surgery and General Hospital, National Medical Center and Ziauddin University Hospital, Karachi, Pakistan from January 2009 to March 2013. Methodology: Hypertension (systolic blood pressure > 160 and diastolic > 90 mmHg with two or more than two medications) with coronary artery disease were initially evaluated for coronary angiography, Renal artery angiography was also endovascular performed and stent was deployed for atherosclerotic renal artery stenosis when found. Blood pressure readings, reduction in need of antihypertensive medication and serum creatinine levels were taken as outcome measures. Patients having renal artery stenoses secondary to connective tissue disorders and fibromuscular dysplasia were excluded. Results: There were 25 patients, 14 (56%) male and 11 (44%) female, with mean age of 49 +- 6 years. Diabetes mellitus, dyslipidemia and smoking were seen in 11 (44%), 10 (40%) and 4 (16%) patients respectively. Renal insufficiency (serum creatinine > 1.5 mg/dl) was seen in one (04%) patient. Bilateral, and isolated right and left renal artery stenoses was seen in 5 (20%), 9 (36%) and 11(44%) patients respectively. Mean percentage of renal artery stenoses was 89%, ranged from 70% to 99% while ostial lesion was found in 20 (80%) patients. A significant decrease in systolic (168.20 +- 9.987 vs. 140.60 +- 5.649 mmHg, p < 0.001) and diastolic blood pressure (88.60 +- 5.50 vs. 77.20 +- 5.017 mmHg, p < 0.001) and reduction of medication (2.72 +- 0.458 vs. 1.5 +- 0.510, p < 0.01) were noted without a change in renal function (p= 0.061) after renal artery stenting. Conclusion: Endovascular stenting of renal artery stenoses in patients with poorly controlled hypertension is a safe and effective treatment

  13. Magnetic resonance angiography compared to intra-arterial digital subtraction angiography in patients with subarachnoid haemorrhage

    International Nuclear Information System (INIS)

    Gouliamos, A.; Gotsis, E.; Vlahos, L.; Samara, C.; Kapsalaki, E.; Rologis, D.; Kapsalakis, Z.; Papavasiliou, C.

    1992-01-01

    In order to evaluate the sensitivity and specificity of magnetic resonance angiography (MRA) in spontaneous subarachnoid haemorrhage, 14 patients with recent haemorrhage verified by CT or lumbar puncture were investigated with both selective intra-arterial digital subtraction angiography (IA-DSA) and MRA by two independent teams, each having the same preangiographic information. The results were compared with each other and whenever possible (all positive cases except one) with those of surgical intervention. Seven patients were identified by MRA and IA-DSA as having a single aneurysm on the circle of Willis, 1 an aneurysm of the posterior inferior cerebellar artery 1 an aneurysm of the internal carotid artery (siphon) and 2 patients with two aneurysms on the circle of Willis. MRA and IA-DSA both failed to demonstrate aneurysms in 2 cases. Three patients had negative results on both methods and no surgical intervention was attempted. The aneurysms ranged from 0.3 to 1.5 cm in size. In most cases there was agreement between MRA and DSA, leading us to believe that, if the proper protocols are followed, MRA is a powerful alternative to other established methods in the detection of intracranial aneurysms. At this stage it will not replace IA-DSA prior to surgery, but the ability to obtain various projections using 3D MRA may improve surgical planning. (orig.)

  14. Magnetic resonance angiography compared to intra-arterial digital subtraction angiography in patients with subarachnoid haemorrhage

    Energy Technology Data Exchange (ETDEWEB)

    Gouliamos, A. (Dept. of Radiology, Athens Univ. (Greece)); Gotsis, E. (Diagnostic and Research Inst. Encephalos, Athens (Greece)); Vlahos, L. (Dept. of Radiology, Athens Univ. (Greece)); Samara, C. (Dept. of Radiology, Athens Univ. (Greece)); Kapsalaki, E. (Diagnostic and Research Inst. Encephalos, Athens (Greece)); Rologis, D. (Dept. of Neurosurgery, Athens General Hospital (Greece)); Kapsalakis, Z. (Diagnostic and Research Inst. Encephalos, Athens (Greece)); Papavasiliou, C. (Dept. of Radiology, Athens Univ. (Greece))

    1992-12-01

    In order to evaluate the sensitivity and specificity of magnetic resonance angiography (MRA) in spontaneous subarachnoid haemorrhage, 14 patients with recent haemorrhage verified by CT or lumbar puncture were investigated with both selective intra-arterial digital subtraction angiography (IA-DSA) and MRA by two independent teams, each having the same preangiographic information. The results were compared with each other and whenever possible (all positive cases except one) with those of surgical intervention. Seven patients were identified by MRA and IA-DSA as having a single aneurysm on the circle of Willis, 1 an aneurysm of the posterior inferior cerebellar artery 1 an aneurysm of the internal carotid artery (siphon) and 2 patients with two aneurysms on the circle of Willis. MRA and IA-DSA both failed to demonstrate aneurysms in 2 cases. Three patients had negative results on both methods and no surgical intervention was attempted. The aneurysms ranged from 0.3 to 1.5 cm in size. In most cases there was agreement between MRA and DSA, leading us to believe that, if the proper protocols are followed, MRA is a powerful alternative to other established methods in the detection of intracranial aneurysms. At this stage it will not replace IA-DSA prior to surgery, but the ability to obtain various projections using 3D MRA may improve surgical planning. (orig.)

  15. Detection and characterization of intracranial aneurysms: magnetic resonance angiography versus digital subtraction angiography

    International Nuclear Information System (INIS)

    Shahzad, R.; Younas, F.

    2011-01-01

    Objective: To compare magnetic resonance angiography (MRA) with Intra-arterial digital subtraction angiography (IA-DSA) in detection and characterization of intracranial aneurysms. Study Design: Comparative cross-sectional study. Place and Duration of Study: Department of Diagnostic Imaging, Lahore General Hospital, Lahore, from January to June 2007. Methodology: Thirty patients presented with aneurysmal subarachnoid haemorrhage (SAH) and focal neurological signs were selected by convenience sampling. Three dimensional time of flight (3D TOF) MRA using maximum intensity projection (MIP) was performed on all patients along with DSA. Results of 3D TOF MRA were compared with those of IA-DSA taking IA-DSA as Gold standard. Results: Out of 30 patients 14 (46.7%) were males and 16 (53.3%) were females with mean age of 41+-14.1 years. MRA detected 29 out of 30 aneurysmal lesions with sensitivity of 96.7%. Regarding characterization of aneurysms results of MRA were comparable to those of IA-DSA. Conclusion: 3D TOF MRA technique showed a high sensitivity in this study. This technique can be used as a non-invasive screening test for intracranial aneurysms and as a suitable alternative primary examination to IA-DSA prior to aneurysmal surgery. (author)

  16. Preoperative transcatheter renal artery embolization with absolute alcohol for the treatment of renal carcinoma: a clinical efficacy analysis

    International Nuclear Information System (INIS)

    Shang Mingyi; Wang Guoliang; Han Hongjie; Xi Qian; Huang Zongliang; Tang Junjun; Gao Xiaolong; Wang Peijun; Lu Ying; Xu Weiguo

    2010-01-01

    Objective: To access the effectiveness of preoperative transcatheter renal artery embolization with absolute alcohol performed before nephrectomy in treating renal carcinoma. Methods: Preoperative transcatheter renal artery embolization with absolute alcohol was performed in 32 patients with renal carcinoma. The renal arteries of the diseased side were progressively occluded, from distal small branches to proximal larger ones, and the renal artery trunk was embolized with gelatin sponge. Radical nephrectomy was carried out 2-5 days after the embolization procedure. The resectional rate of the tumor, the blood loss during the surgery and the operation time were recorded and analyzed. Results: Angiography performed immediately after the embolization showed that complete embolization of the main renal artery was achieved in all 32 patients. The resectional rate of the tumor was 100%. During the surgery, shrinkage of tumor, collapse of renal superficial veins and marked perinephric edema were observed. The blood loss during the surgery was much less and the operation time cost was much shorter than a usual nephrectomy did. Conclusion: The preoperative transcatheter renal artery embolization with absolute alcohol is an effective therapeutic means for renal carcinoma, it can definitely reduce the surgical blood loss and shorten the operative time. (authors)

  17. ECG-gating in non-cardiac digital subtraction angiography

    International Nuclear Information System (INIS)

    Gattoni, F.; Baldini, V.; Cairo, F.

    1987-01-01

    This paper reports the results of the ECG-gating in non-cardiac digital subtraction angiography (DSA). One hundred and fifteen patients underwent DSA (126 examinations); ECG-gating was applied in 66/126 examinations: images recorded at 70% of R wave were subtracted. Artifacts produced by vascular movements were evaluated in all patients: only 40 examinations, carried out whithout ECG-gating, showed vascular artifacts. The major advantage of the ECG-gated DSA is the more efficent subtraction because of the better images superimposition: therefore, ECG-gating can be clinically helpful. On the contrary, it could be a problem in arrhytmic or bradycardic patients. ECG-gating is helpful in DSA imaging of the thoracic and abdominal aorta and of the cervical and renal arteries. In the examinations of peripheral vessels of the limbs it is not so efficent as in the trunk or in the neck

  18. MR angiography of the body. Technique and clinical applications

    Energy Technology Data Exchange (ETDEWEB)

    Neri, Emanuele [Pisa Univ. Radiodiagnostica 1 Universitaria (Italy). Diagnostic and Interventional Radiology Dept. of Oncology, Transplants, and Advanced Technologies in Medicine; Cosottini, Mirco [Pisa Univ. (Italy). Unit of Neuroradiology Dept. of Neurosciences; Caramella, Davide (eds.) [Pisa Univ. (Italy). Diagnostic and Interventional Radiology Dept. of Oncology, Transplants, and Advanced Technologies in Medicine

    2010-07-01

    Magnetic resonance angiography (MRA) continues to undergo exciting technological advances that are rapidly being translated into clinical practice. It also has evident advantages over other imaging modalities, including better patient safety compared with CT angiography and superior accuracy and contrast resolution compared with ultrasonography. With the aid of numerous high-quality illustrations, this book reviews the current role of MRA of the body. It is divided into three sections. The first section is devoted to issues relating to image acquisition technique and sequences. Individual chapters focus on flow-based MRA, contrast media, contrast-enhanced MRA, artifacts, and image processing. The second and principal section of the book addresses the clinical applications of MRA in various parts of the body, including the neck vessels, the spine, the thoracic aorta and pulmonary vessels, the heart and coronary arteries, the abdominal aorta and renal arteries, and peripheral vessels. The role of the blood pool contrast agents for the diagnosis and characterization of vascular disease is fully explored. The final section considers the role of MRA in patients undergoing liver or pancreas and kidney transplantation. This book will be an invaluable aid to all radiologists who work with MRA. (orig.)

  19. Your Radiologist Explains Magnetic Resonance Angiography (MRA)

    Medline Plus

    Full Text Available ... Sponsored by Image/Video Gallery Your Radiologist Explains Magnetic Resonance Angiography (MRA) Transcript Welcome to Radiology Info dot ... I’d like to talk with you about magnetic resonance angiography, or as it’s commonly known, MRA. MRA ...

  20. Selective cyclooxygenase-2 inhibitor use and progression of renal function in patients with chronic kidney disease: a single-center retrospective cohort study

    Directory of Open Access Journals (Sweden)

    Kaewput W

    2016-11-01

    Full Text Available Wisit Kaewput,1,2 Preedee Disorn,2 Bancha Satirapoj2 1Department of Military and Community Medicine, Phramongkutklao College of Medicine, 2Department of Medicine, Phramongkutklao Hospital and College of Medicine, Bangkok, Thailand Background: The use of selective COX-2 (sCOX-2 inhibitors with acute kidney injury, salt water retention, and cardiovascular events have been correlated in subjects with normal kidney function, but sCOX-2 inhibitor use concerning the progression of chronic kidney disease (CKD remains uncertain. Objectives: To determine the progression of renal function and electrolyte abnormalities among CKD patients after using sCOX-2 inhibitors during short- and long-term periods. Methods: The study employed a retrospective cohort design comprising all types of CKD patients with and without sCOX-2 inhibitors (celecoxib and etoricoxib. Data collected included medical data, estimated glomerular filtration rate (eGFR, and serum electrolytes at 3 and 6 months between January 2009 and January 2014. Subjects attended the outpatient clinic and were then followed up until discontinuation of the drugs at years 1 and 2 until May 2016. Results: Ninety-two CKD patients on sCOX-2 inhibitors and 92 CKD patients without sCOX-2 inhibitors were included. The sCOX-2 inhibitor group showed more decline in eGFR than the control group at 3 and 6 months of follow-up (–8.27±9.75 vs –1.64±6.05 mL/min/1.73 m2, P<0.001 and –12.36±6.48 vs –4.31±5.11 mL/min/1.73 m2, P=0.001, respectively and at 1 and 2 years of follow-up after subjects discontinued sCOX-2 (–6.84±10.34 vs –1.61±8.93 mL/min/1.73 m2, P=0.004 and –10.26±10.19 vs –5.12±8.61 mL/min/1.73 m2, P=0.005, respectively. In addition, the sCOX-2 inhibitor group had significantly more increased serum potassium during the study follow-up than the control group. Conclusion: The sCOX-2 inhibitors are associated with an increased risk for rapid eGFR decline and hyperkalemia in both the

  1. A study of transverse image reconstruction with digital subtraction angiography

    International Nuclear Information System (INIS)

    Sakamoto, Kiyoshi; Kotoura, Noriko; Terasawa, Yuuji; Oda, Masahiko; Gotou, Hiroshi; Nasada, Toshiya; Tanooka, Masao

    1995-01-01

    For digital subtraction angiography (DSA) with C-type equipment, it is possible to radiate an X-ray during rotation and to collect data at different angular settings. We tried to reconstruct transverse image from data obtained by scanning DSA images at different angular settings. 88 projection data were obtained by rotating the object at 180deg during radiation. Reconstruction was made using the convolution method with pixel value distribution for each projection. Similarly, the image quality of the reconstructed images were compared with the unsubtracted and subtracted ones. In case a part object was outside the calculating region, artifacts were generally produced. However, the artifacts were reduced by subtracting the background from the image. In addition, the cupping phenomenon caused by beam hardening was relaxed and high-quality imaging could be achieved. This method will become even more effective, if we will use it with selective angiography in which the limited area is enhanced. (author)

  2. Intracranial arterial anatomy: evaluation by computed tomography angiography

    International Nuclear Information System (INIS)

    Regattieri, Neysa Aparecida Tinoco; Haetinger, Rainer Guilherme; Liberti, Edson Aparecido

    2010-01-01

    By many decades, the intracranial arteries study was realized exclusively by angiography through selective arterial catheterization. Nowadays, with the technologic evaluation of computerized tomography devices with multi detectors allowing acquisitions with even more thinner slices, higher speed and better resolution, it had appeared a new modality of investigation: the computed tomography angiography, less invasive and with minor morbidity than conventional arteriography. Many studies in the literature have been analyzing the sensibility of the new method for the detection of intracranial aneurysms and comparing them with the conventional arteriography. There is a necessity to recognize the normal intracranial arterial anatomy and its variations using images obtained from multiplanar reformations, in order to give important information for surgeries strategies, such as wall calcifications, aneurismatic neck position and relationships with surrounding anatomical structures. (author)

  3. Valutazione morfo-funzionale in pazienti ipertesi con stenosi dell'arteria renale

    International Nuclear Information System (INIS)

    Cuocolo, A.; Celentano, L.; Nappi, A.; Neumann, R.D.; Salvatore, M.

    1991-01-01

    Renovascula hypertension is the most important and common cause of secondary hypertension. We studied 10 patients with arterial hypertension and different degrees of renal artery stenosis to assess the usefulness of dynamic radionuclide renography in evaluating renal perfusion and funcion, and to compare funcional radionuclide results to the morphological findings of renal angiography. Computer-assisted dynamic renal with 00m Tc diethylenetriaminepentaacetic acid (DTPA) and 131 I orthoiodohippurate (OIH), and renal artheriography were also employed in all patients. In all patients, radionuclide results matched angiography findings in quality. In particular, 3 patients with hemodynamical insignificant renal artery stenosis exhibited normal perfusion and function at dynamic radionuclide renography. Seven patients had significant renal artery stenosis and associated functional changes at dynamic radionuclide renography. Quantitative comparison of all patients showed a significant correlation (r=0.866, p<0.001) between the degree of renal artery stenosis, quantified as the percentage of narrowing as compared to adjacent/contralateral normal vessel diameter, and the results of split renal function, as assessed during OIH studies and expressed per kidney as a percentage of the net total counts of both kidneys. In conclusion, our results demonstrated dynamic radionuclide renography to be a valuable secondary to renal artery stenosis in hypertensive patients, providing complementary results to arteriography

  4. Renal denervation and hypertension.

    Science.gov (United States)

    Schlaich, Markus P; Krum, Henry; Sobotka, Paul A; Esler, Murray D

    2011-06-01

    Essential hypertension remains one of the biggest challenges in medicine with an enormous impact on both individual and society levels. With the exception of relatively rare monogenetic forms of hypertension, there is now general agreement that the condition is multifactorial in nature and hence requires therapeutic approaches targeting several aspects of the underlying pathophysiology. Accordingly, all major guidelines promote a combination of lifestyle interventions and combination pharmacotherapy to reach target blood pressure (BP) levels in order to reduce overall cardiovascular risk in affected patients. Although this approach works for many, it fails in a considerable number of patients for various reasons including drug-intolerance, noncompliance, physician inertia, and others, leaving them at unacceptably high cardiovascular risk. The quest for additional therapeutic approaches to safely and effectively manage hypertension continues and expands to the reappraisal of older concepts such as renal denervation. Based on the robust preclinical and clinical data surrounding the role of renal sympathetic nerves in various aspects of BP control very recent efforts have led to the development of a novel catheter-based approach using radiofrequency (RF) energy to selectively target and disrupt the renal nerves. The available evidence from the limited number of uncontrolled hypertensive patients in whom renal denervation has been performed are auspicious and indicate that the procedure has a favorable safety profile and is associated with a substantial and presumably sustained BP reduction. Although promising, a myriad of questions are far from being conclusively answered and require our concerted research efforts to explore the full potential and possible risks of this approach. Here we briefly review the science surrounding renal denervation, summarize the current data on safety and efficacy of renal nerve ablation, and discuss some of the open questions that need

  5. Exercise intravenous digital subtraction angiography

    International Nuclear Information System (INIS)

    Yiannikas, J.

    1986-01-01

    Attempts to use exercise ventriculography have been made, not only to give diagnostic and perhaps even prognostic information in patients with coronary artery disease, but also in patients with valvular heart disease both before and after surgical intervention. Clearly an accurate method of assessing ventricular function under conditions of stress in various cardiac diseases would provide important information that would help in patient management. Exercise ventriculography using gated blood pool equilibrium technetium studies are widely used, but are limited by spatial resolution and by the foreshortening affects of visualizing the left ventricular chamber in the left anterior oblique view. First pass radionuclide studies have the added advantage of being able to visualize the ventricular chamber in the anterior or even the right anterior oblique view, but are even more limited by their spatial resolution problems. Several investigations have shown that digital subtraction angiography produces left ventricular images with a spatial resolution almost identical to that of conventional contrast ventriculography, but without the inherent problems of cardiac arrhythmias, which often limit the assessment of left ventricular function. Because of its ability to accurately delineate wall motion abnormalities, the technique may provide an adequate assessment of global and regional left ventricular function after exercise. Digital subtraction angiography may identify ischemic wall motion abnormalities produced by exercise in patients who already had significant permanent left ventricular damage from myocardial infarction

  6. Hypogonadism and renal failure: An update.

    Science.gov (United States)

    Thirumavalavan, Nannan; Wilken, Nathan A; Ramasamy, Ranjith

    2015-01-01

    The prevalence of both hypogonadism and renal failure is increasing. Hypogonadism in men with renal failure carries with it significant morbidity, including anemia and premature cardiovascular disease. It remains unclear whether testosterone therapy can affect the morbidity and mortality associated with renal failure. As such, in this review, we sought to evaluate the current literature addressing hypogonadism and testosterone replacement, specifically in men with renal failure. The articles chosen for this review were selected by performing a broad search using Pubmed, Embase and Scopus including the terms hypogonadism and renal failure from 1990 to the present. This review is based on both primary sources as well as review articles. Hypogonadism in renal failure has a multifactorial etiology, including co-morbid conditions such as diabetes, hypertension, old age and obesity. Renal failure can lead to decreased luteinizing hormone production and decreased prolactin clearance that could impair testosterone production. Given the increasing prevalence of hypogonadism and the potential morbidity associated with hypogonadism in men with renal failure, careful evaluation of serum testosterone would be valuable. Testosterone replacement therapy should be considered in men with symptomatic hypogonadism and renal failure, and may ameliorate some of the morbidity associated with renal failure. Patients with all stages of renal disease are at an increased risk of hypogonadism that could be associated with significant morbidity. Testosterone replacement therapy may reduce some of the morbidity of renal failure, although it carries risk.

  7. Three-dimensional magnetic resonance angiography of vascular lesions in children.

    Science.gov (United States)

    Katayama, H; Shimizu, T; Tanaka, Y; Narabayashi, I; Tamai, H

    2000-01-01

    We applied three-dimensional (3D) magnetic resonance (MR) angiography to vascular lesions in children and evaluated the clinical usefulness of this technique. Ten patients, whose ages ranged from 1 month to 16 years, underwent 3D MR angiography for 12 vascular lesions, including lesions in seven pulmonary arteries, two thoracic aortae, a pair of renal arteries, and one iliac artery. Three-dimensional MR angiography was performed with body-or pelvic-phased array coils on a 1.5-T scanner using fast spoiled gradient echo sequence. Data were acquired with the following parameters: TE, 1.9 ms; TR, 10.1 ms; flip angle, 20-60 degrees ; 1 or 2 NEX; field of view, 24-48 x 18-40 cm; matrix, 256 or 512 x 128 or 256; slice thickness, 1.2-7.5 mm; and 12, 28, or 60 partitions. Vascular imaging was enhanced with 20% gadolinium-diethylenetriaminepentaacetic acid. The examination was performed under breath-holding in six patients and with shallow breathing in four patients. In a comparative study with other noninvasive methods, 3D MR angiography was superior in seven of nine cases to other noninvasive examinations and in two cases, all methods evaluated the lesions. Furthermore, six cases were compared with conventional angiography. In five of the six cases, both methods depicted the lesions similarly, and in one case, MR angiography was more effective. A quantitative comparison of vascular diameter in the MR image was made with that in the conventional angiographic image. The correlation between them was excellent: y = 1.145x-2.090 (r = 0.987; P children.

  8. Accessory renal arteries: Prevalence in resistant hypertension and an important role in nonresponse to radiofrequency renal denervation.

    Science.gov (United States)

    VonAchen, Paige; Hamann, Jason; Houghland, Thomas; Lesser, John R; Wang, Yale; Caye, David; Rosenthal, Kristi; Garberich, Ross F; Daniels, Mary; Schwartz, Robert S

    The aim of this study was to understand the role of accessory renal arteries in resistant hypertension, and to establish their role in nonresponse to radiofrequency renal denervation (RDN) procedures. Prior studies suggest a role for accessory renal arteries in hypertensive syndromes, and recent clinical trials of renal denervation report that these anomalies are highly prevalent in resistant hypertension. This study evaluated the relationships among resistant hypertension, accessory renal arteries, and the response to radiofrequency (RF) renal denervation. Computed Tomography Angiography (CTA) and magnetic resonance imaging (MRI) scans from 58 patients with resistant hypertension undergoing RF renal denervation (RDN) were evaluated. Results were compared with CT scans in 57 healthy, normotensive subjects undergoing screening as possible renal transplant donors. All scans were carefully studied for accessory renal arteries, and were correlated with long term blood pressure reduction. Accessory renal arteries were markedly more prevalent in the hypertensive patients than normotensive renal donors (59% vs 32% respectively, p=0.004). RDN had an overall nonresponse rate of 29% (response rate 71%). Patients without accessory vessels had a borderline higher response rate to RDN than those with at least one accessory vessel (83% vs 62% respectively, p=0.076) and a higher RDN response than patients with untreated accessory arteries (83% vs 55%; p=0.040). For accessory renal arteries and nonresponse, the sensitivity was 76%, specificity 49%, with positive and negative predictive values 38% and 83% respectively. Accessory renal arteries were markedly over-represented in resistant hypertensives compared with healthy controls. While not all patients with accessory arteries were nonresponders, nonresponse was related to both the presence and non-treatment of accessory arteries. Addressing accessory renal arteries in future clinical trials may improve RDN therapeutic efficacy

  9. Diagnostic value of digital subtraction angiography (DSA) using TOSHIBA DIGIFORMER X in the cerebrospinal vascular diseases

    International Nuclear Information System (INIS)

    Ishikawa, Tatsuya; Nakagawa, Yoku; Sawamura, Yutaka; Kobayashi, Nobuaki; Nagashima, Masafumi; Kitaoka, Ken-ichi; Kitagawa, Michio; Itoh, Terufumi; Ohsato, Takao.

    1987-01-01

    Using TOSHIBA Digiformer X, digital subtraction angiography (DSA) was performed in 286 patients, in whom 229 patients of cerebro-spinal vascular disease was included. The authors emphasize the usefulness of DSA in cerebro-spinal vascular disease in relation to conventional angiography. DSA taken by single small dose injection of contrast medium into the ascending aorta clearly demonstrates not only aortic arch and thoracic major vessels, but also cervical vessels and all intracranial vessels. Therefore, we could rapidly understand gross dynamics of the circulation and obtain useful informations prior to catheterization to the selective artery. This advantage of DSA was particularly useful for occlusive vascular diseases. Gradual injection of small dose of contrast medium obviously reduced recoiling of the catheter tip, which enabled the selective angiography with setting of the tip of the catheter at the entrance of cervical major vessels without its sufficient inserion into the selective vessels. This advantage is particularly beneficial for the patients with severe arteriosclerosis who was found to be difficult for selective catheterization. In our experience, demonstration of a presence of aneurysm by DSA was possible in almost all cases of subarachnoid hemorrhage, although spatial resolution of DSA is said to be inferior to the conventional angiography. Real time display of DSA decreased the time required for examination and enabled repeated angiography. This advantage of DSA is especially useful for the patients with spinal arterio-venous malformation and thoracic outlet syndrome. (author)

  10. Renal artery stenosis: comparative assessment by unenhanced renal artery mra versus contrast-enhanced MRA

    International Nuclear Information System (INIS)

    Khoo, Michael M.Y.; Deeab, Dhafer; Gedroyc, Wladyslaw M.W.; Dick, Elizabeth A.; Duncan, Neil; Taube, David

    2011-01-01

    To evaluate steady-state free precession (SSFP) non-contrast-enhanced MR angiography (Unenhanced-MRA) versus conventional contrast-enhanced MR angiography (CE-MRA) in the detection of renal artery stenosis (RAS). Retrospective analysis of 70 consecutive patients referred for suspected RAS, examined by SSFP Unenhanced-MRA and CE-MRA. Image quality, quality of visible renal arterial segments, presence and grade of RAS were evaluated. The Unenhanced-MRA were compared against reference standard CE-MRA results. 149 renal arteries were assessed with 21 haemodynamically significant stenoses (≥50% stenosis) demonstrated by CE-MRA. Combined sensitivity and specificity for RAS detection by Unenhanced-MRA was 72.8% and 97.8% respectively. There is substantial correlation for RAS detection between Unenhanced-MRA and CE-MRA with kappa values of between 0.64 and 0.74. There was excellent inter-observer correlation for RAS on Unenhanced-MRA (kappa values 0.82-1.0). Our study has shown Unenhanced-MRA to be a viable alternative to CE-MRA, yielding images equal in quality without the requirement for gadolinium contrast agents. The sensitivity and specificity for the detection of haemodynamically significant stenoses are comparable to CE-MRA. Potentially, Unenhanced-MRA could be used as an initial investigation to avoid performing CE-MRA in patients with normal renal arteries, however we suggest that its real value will lie in being complementary to CE-MRA. (orig.)

  11. Anatomic variation in the origin of the main renal arteries: spiral CTA evaluation

    International Nuclear Information System (INIS)

    Beregi, J.P.; Willoteaux, S.; Remy-Jardin, M.; Mauroy, B.; Francke, J.P.; Mounier-Vehier, C.

    1999-01-01

    The aim of this study was to provide quantitative data on the origin and trajectory of the main renal arteries using spiral CT angiography and arteriography. Normal renal artery anatomy was assessed on spiral CT angiography (axial transverse sections and shaded-surface-display reconstructions) in 100 patients referred for renal arteriography who had no significant renal artery stenosis. Two hundred major renal arteries were studied. The vast majority of right (88 %) and left (87 %) renal arteries originated between the lower third of the first lumbar vertebra and the lower border of the second lumbar vertebra. In 50 patients both ostia were at the same level; in the remaining 50 patients, the right ostium was located above the left in 37 patients. On the right, the angle of origin varied from -10 to + 55 (mean + 24 ). On the left, the angle of origin varied from + 30 to -55 (mean -11 ). Spiral CT angiography provides additional anatomic data, notably regarding the angle of origin of the renal arteries, that is potentially useful for planning interventional procedures. (orig.)

  12. Anatomic variation in the origin of the main renal arteries: spiral CTA evaluation

    Energy Technology Data Exchange (ETDEWEB)

    Beregi, J.P.; Willoteaux, S.; Remy-Jardin, M. [Department of Vascular Radiology, Hopital Cardiologique, 59 - Lille (France); Mauroy, B.; Francke, J.P. [Laboratoire d`Anatomie, Univ. de Lille (France); Mounier-Vehier, C. [Department of Hypertension and Internal Medicine, Hopital Cardiologique, Lille (France)

    1999-09-01

    The aim of this study was to provide quantitative data on the origin and trajectory of the main renal arteries using spiral CT angiography and arteriography. Normal renal artery anatomy was assessed on spiral CT angiography (axial transverse sections and shaded-surface-display reconstructions) in 100 patients referred for renal arteriography who had no significant renal artery stenosis. Two hundred major renal arteries were studied. The vast majority of right (88 %) and left (87 %) renal arteries originated between the lower third of the first lumbar vertebra and the lower border of the second lumbar vertebra. In 50 patients both ostia were at the same level; in the remaining 50 patients, the right ostium was located above the left in 37 patients. On the right, the angle of origin varied from -10 to + 55 (mean + 24 ). On the left, the angle of origin varied from + 30 to -55 (mean -11 ). Spiral CT angiography provides additional anatomic data, notably regarding the angle of origin of the renal arteries, that is potentially useful for planning interventional procedures. (orig.) With 4 figs., 19 refs.

  13. Mid-term outcomes of endovascular aortic aneurysm repair with carbon dioxide-guided angiography.

    Science.gov (United States)

    Takeuchi, Yuriko; Morikage, Noriyasu; Matsuno, Yutaro; Nakamura, Tamami; Samura, Makoto; Ueda, Koshiro; Harada, Takasuke; Ikeda, Yoshitaka; Suehiro, Kotaro; Ito, Hiroshi; Sakata, Kensuke; Hamano, Kimikazu

    2018-05-14

    Although iodinated contrast (IC) agents are commonly used in endovascular aneurysm repair (EVAR), perioperative use in patients with renal dysfunction or IC allergies is avoided. Carbon dioxide (CO 2 )-guided angiography is a promising alternative. We aimed to evaluate short-term and mid-term outcomes of EVAR using CO 2 -guided angiography. Three hundred and eighty-one patients who underwent EVAR from January 2012 to September 2016 were retrospectively reviewed and divided into an IC-EVAR group (n=351) and CO 2 -EVAR group (n=30). Subjects in the CO 2 -EVAR group had severe renal dysfunction (n=27) and IC allergy (n=4). Intraoperative, postoperative, and follow-up variables were compared. Compared to the IC-EVAR group, preoperative serum creatinine level was significantly higher (2.0 vs. 0.92 mg/dL, P < .0001) and mean IC dose significantly lower (18 vs. 55 mL P < .0001) in the CO 2 -EVAR group. The fluoroscopy time, operative time, number of stent grafts placed, and technical success rates of the groups were similar; no type I and/or type III endoleaks were detected on completion angiography. There was no acute kidney injury and one case of intestinal necrosis in the CO 2 -EVAR group, potentially due to cholesterol embolism. Postoperative endoleak, enlargement of aneurysms, survival, freedom from secondary intervention, and renal function change up to 3 months postoperatively were similar between groups. CO 2 -EVAR is technically feasible and exhibits prominent renal protection. However, consideration of the aortic lumen status remains an important challenge. Copyright © 2018. Published by Elsevier Inc.

  14. Outcomes after Angiography with Sodium Bicarbonate and Acetylcysteine.

    Science.gov (United States)

    Weisbord, Steven D; Gallagher, Martin; Jneid, Hani; Garcia, Santiago; Cass, Alan; Thwin, Soe-Soe; Conner, Todd A; Chertow, Glenn M; Bhatt, Deepak L; Shunk, Kendrick; Parikh, Chirag R; McFalls, Edward O; Brophy, Mary; Ferguson, Ryan; Wu, Hongsheng; Androsenko, Maria; Myles, John; Kaufman, James; Palevsky, Paul M

    2018-02-15

    Intravenous sodium bicarbonate and oral acetylcysteine are widely used to prevent acute kidney injury and associated adverse outcomes after angiography without definitive evidence of their efficacy. Using a 2-by-2 factorial design, we randomly assigned 5177 patients at high risk for renal complications who were scheduled for angiography to receive intravenous 1.26% sodium bicarbonate or intravenous 0.9% sodium chloride and 5 days of oral acetylcysteine or oral placebo; of these patients, 4993 were included in the modified intention-to-treat analysis. The primary end point was a composite of death, the need for dialysis, or a persistent increase of at least 50% from baseline in the serum creatinine level at 90 days. Contrast-associated acute kidney injury was a secondary end point. The sponsor stopped the trial after a prespecified interim analysis. There was no interaction between sodium bicarbonate and acetylcysteine with respect to the primary end point (P=0.33). The primary end point occurred in 110 of 2511 patients (4.4%) in the sodium bicarbonate group as compared with 116 of 2482 (4.7%) in the sodium chloride group (odds ratio, 0.93; 95% confidence interval [CI], 0.72 to 1.22; P=0.62) and in 114 of 2495 patients (4.6%) in the acetylcysteine group as compared with 112 of 2498 (4.5%) in the placebo group (odds ratio, 1.02; 95% CI, 0.78 to 1.33; P=0.88). There were no significant between-group differences in the rates of contrast-associated acute kidney injury. Among patients at high risk for renal complications who were undergoing angiography, there was no benefit of intravenous sodium bicarbonate over intravenous sodium chloride or of oral acetylcysteine over placebo for the prevention of death, need for dialysis, or persistent decline in kidney function at 90 days or for the prevention of contrast-associated acute kidney injury. (Funded by the U.S. Department of Veterans Affairs Office of Research and Development and the National Health and Medical Research

  15. Intra-arterial Ultra-low-Dose CT Angiography of Lower Extremity in Diabetic Patients

    Energy Technology Data Exchange (ETDEWEB)

    Özgen, Ali, E-mail: draliozgen@hotmail.com [Yeditepe University Hospital, Department of Radiology (Turkey); Sanioğlu, Soner [Yeditepe University Hospital, Department of Cardiovascular Surgery (Turkey); Bingöl, Uğur Anıl [Yeditepe University Hospital, Department of Plastic Surgery (Turkey)

    2016-08-15

    PurposeTo image lower extremity arteries by CT angiography using a very low-dose intra-arterial contrast medium in patients with high risk of developing contrast-induced nephropathy (CIN).Materials and MethodsThree cases with long-standing diabetes mellitus and signs of lower extremity atherosclerotic disease were evaluated by CT angiography using 0.1 ml/kg of the body weight of contrast medium given via 10-cm-long 4F introducer by puncturing the CFA. Images were evaluated by an interventional radiologist and a cardiovascular surgeon. Density values of the lower extremity arteries were also calculated. Findings in two cases were compared with digital subtraction angiography images performed for percutaneous revascularization. Blood creatinine levels were followed for possible CIN.ResultsIntra-arterial CT angiography images were considered diagnostic in all patients and optimal in one patient. No patient developed CIN after intra-arterial CT angiography, while one patient developed CIN after percutaneous intervention.ConclusionIntra-arterial CT angiography of lower extremity might be performed in selected patients with high risk of developing CIN. Our limited experience suggests that as low as of 0.1 ml/kg of the body weight of contrast medium may result in adequate diagnostic imaging.

  16. Comparison between fast contrast-enhanced MR angiography and DSA in diagnosing spinal cord vascular malformations

    International Nuclear Information System (INIS)

    Wang Wu; Li Minghua; Fang Chun; Wang Jue; Xiao Yunfeng

    2007-01-01

    Objective: To evaluate the diagnostic and clinical value of fast contrast-enhanced MR angiography (CE-MRA) with elliptic centric phase-encoding in spinal cord vascular malformations. Methods Fast three-dimensional contrast-enhanced MR angiography with elliptic centric phase-encoding and superconducting 1.5T system was applied prospectively in twenty-five consecutive patients with clinically suspected of spinal cord vascular malformations. All cases were performed with selective spinal digital subtraction angiography, including 18 cases treated by surgery and 2 of them with embolization before surgery, MR angiography follow up were undertaken in ten patients after surgery. Comparing fast contrast-enhanced MR angiography with DSA in diagnosing spinal cord vascular malformations included the origin of feeding artery, the feeding artery, the fistula or the nidus, the draining vein, and the vessel image quality based on the gold standard of selective spinal digital subtraction angiography. Results: Surgically proven diseases included spinal arteriovenous malformations(3 cases), spinal cord perimedullary arteriovenous fistulas (5 cases), spinal dural arteriovenous fistulas (8 cases), paravertebral arteriovenous fistulas (1 case), and spontaneous spinal epidural hematomas (2 eases). Comparing with DSA, the accuracy of MR angiography in diagnosing spinal cord vascular malformations; and detecting the origin of the feeding artery, the feeding artery, the shunt or the nidus and the draining vein were 93.8%, 92%, 96.2%, 100% and 100%, respectively. Overall the degree vascular enhencement were judged to be similar(P>0.05), but the vessel continuity of MRA was inferior to DSA (P<0.05). However, 9 cases of MRA showed no abnormal vascular malformation coinciding with those of surgery. Posttreatment MR angiography did not depict any abnormal vessels again. Conclusions: Fast three-dimensional contrast-enhanced MR angiography with elliptic centric phase-encoding may provide

  17. Renal artery stent angioplasty for renovascular hypertension

    International Nuclear Information System (INIS)

    Li Gang; Li Haiqing; Wang Lin

    2005-01-01

    Objective: To evaluate the therapeutic results of expandable stent for treatment of atherosclerotic renovascular obstructive disease. Methods: 15 patients (10 men and 5 women, 41-75 years old; mean age, 52 years) with renal arterial hypertension underwent renal stent angioplasty including renal arterial stenosis 89%(n=13) and fully obstruction without function in 2, of which 2 patients had bilateral involvement. The stenotic range of all arterial segments showed 60% to 90% width of the normal arterial diameter. 16 stents were implanted under the guidance of fluoroscopy. The most of stents implanted were Palmaz (n=12, 75%) with regular clinical and angiographic follow up. Results: Technical success (residual stenosis <30%) was achieved in all patients without serious complication. During the follow-up (6-15 months; mean, 8 ± 4 months), hypertension was improved in 9 patients and cured in 4 patients with a total benefit of 86% and no efficacy in 2(13%). The average systolic blood pressure decreased from 27.12 ± 3.09 kPa to 18.62 ± 3.12 kPa and the average diastolic blood pressure decreased from 17.73 ± 1.92 kPa to 11.12 ± 2.43 kPa after stent treatment (P<0.05). Serum creatinine remained stable in 60% (n=9) patients with improvement in 33% (n=5) and worsened in 6% (n=1) patients. Follow-up angiography was performed in all patients with 1 case of a restenosis. 6 months after expanding through stent by using balloon, the two follow up angiographies showed a stable restenosis about 20%. Conclusions: Percutaneous transluminal stent placement is highly beneficial for patients who had renal arterial obstructive disease. The success of stent angioplasty of complete obstructive renal arteries reveals wide prospects for interventional method. (authors)

  18. Superselective transcatheter renal arterial embolization for acute renal bleeding in patients with renal insufficiency: its clinical efficacy and safety

    International Nuclear Information System (INIS)

    Hu Tingyang; Zhou Bing; Yu Wenqiang; Luo Zuyan; Mao Yingmin; Chen Fanghong; Li Bo; Yuan Jianhua

    2010-01-01

    Objective: To discuss the clinical efficacy and complications of super selective renal arterial embolization in treating acute renal arterial bleeding in patients with renal insufficiency, and to evaluate the influence of the treatment on the renal function. Methods: During the period of January 2000 December 2009, super selective renal arterial embolization was performed in our institution for acute renal bleeding in 13 patients with renal insufficiency. The complete clinical and imaging materials of all patients were properly collected. The clinical effectiveness, the renal function, the extent of embolization and the complications were observed and the relationship between each other was analyzed. Results: The embolization procedure was successfully completed in all patients with a technical success rate of 100%. The mean embolized territory was 22% of a single kidney. Three days after the procedure, the hemoglobin level, hematocrit, blood pressure and heart rate were considerably improved in all patients. Compared to the corresponding preoperative data, all the differences were statistically significant (P 0.05), while the blood urea nitrogen was markedly decreased (P=0.011). Post embolization syndrome occurred in 5 patients and progressive aggravation of the renal function was observed in one patient, who had to receive hemodialysis finally. The embolized territory in patients occurring complications was larger than that in patients without occurring complications (U=1.500, P=0.006). Conclusion: Super selective renal arterial embolization is an effective and safe treatment for acute renal arterial bleeding in patients with renal insufficiency, the therapy will not significantly worsen the renal function. Appropriate and reasonable extent of embolization, as small as possible, is the key point for reducing the complications. (authors)

  19. Late evaluation of the relationship between morphological and functional renal changes and hypertension after non-operative treatment of high-grade renal injuries

    Directory of Open Access Journals (Sweden)

    Pereira Júnior Gerson

    2012-08-01

    Full Text Available Abstract Objective To evaluate the anatomical and functional renal alterations and the association with post-traumatic arterial hypertension. Methods The studied population included patients who sustained high grades renal injury (grades III to V successfully non-operative management after staging by computed tomography over a 16-year period. Beyond the review of medical records, these patients were invited to the following protocol: clinical and laboratory evaluation, abdominal computed tomography, magnetic resonance angiography, DMSA renal scintigraphy, and ambulatory blood pressure monitoring. The hypertensive patients also were submitted to dynamic renal scintigraphy (99mTc EC, using captopril stimulation to verify renal vascular etiology. Results Of the 31 patients, there were thirteen grade III, sixteen grade IV (nine lacerations, and seven vascular lesions, and two grade V injuries. All the patients were asymptomatic and an average follow up post-injury of 6.4 years. None had abnormal BUN or seric creatinine. The percentage of renal volume reduction correlates with the severity as defined by OIS. There was no evidence of renal artery stenosis in Magnetic Resonance angiography (MRA. DMSA scanning demonstrated a decline in percentage of total renal function corresponding to injury severity (42.2 ± 5.5% for grade III, 35.3 ± 12.8% for grade IV, 13.5 ± 19.1 for grade V. Six patients (19.4% had severe compromised function ( Conclusions Late results of renal function after conservative treatment of high grades renal injuries are favorable, except for patients with grades IV with vascular injuries and grade V renal injuries. Moreover, arterial hypertension does not correlate with the grade of renal injury or reduction of renal function.

  20. Magnetic resonance angiography of arteriovenous malformation in the brainstem

    Energy Technology Data Exchange (ETDEWEB)

    Oyama, Hirofumi; Kida, Yoshihisa; Kobayashi, Tatsuya; Tanaka, Takayuki; Iwakoshi, Takayasu; Kai, Osamu; Hirose, Mitsuhiko [Komaki City Hospital, Aichi (Japan)

    1993-11-01

    The magnetic resonance (MR) angiography appearance of arteriovenous malformation (AVM) in the tegmentum and pons is described. The interpeduncular perforating branches of the posterior cerebral artery and median pontine branches of the basilar artery were seen more clearly by MR angiography than by conventional angiography. MR angiography was very useful for the follow-up of AVM after stereotactic radiosurgery. (author).

  1. Digital subtraction angiography of the heart and lungs

    International Nuclear Information System (INIS)

    Moodie, D.S.; Yiannikas, J.

    1986-01-01

    This book contains 12 chapters. Some of the chapter titles are: Physical Principles of Cardiac Digital Subtraction Angiography, The Use of Intravenous Digital Subtraction Angiography in Evaluating Patients with Complex Congenital Heart Disease, Exercise Intravenous Digital Subtraction Angiograpny, Cardiomyopathic and Cardiac Neoplastic Disease, Digital Subtraction Angiography in the Catheterization Laboratory, and Cardiac Digital Subtraction Angiography - Future Directions

  2. Pharmacokinetics and Pharmacodynamics of Luseogliflozin, a Selective SGLT2 Inhibitor, in Japanese Patients With Type 2 Diabetes With Mild to Severe Renal Impairment.

    Science.gov (United States)

    Samukawa, Yoshishige; Haneda, Masakazu; Seino, Yutaka; Sasaki, Takashi; Fukatsu, Atsushi; Kubo, Yusuke; Sato, Yuri; Sakai, Soichi

    2018-04-25

    This open-label, parallel-group, multicenter study aimed to assess the effects of renal impairment on the pharmacokinetics, pharmacodynamics, and safety of luseogliflozin. A single 5-mg dose of luseogliflozin was administered to Japanese patients with type 2 diabetes mellitus in the following groups: G1, normal renal function; G2, mild renal impairment; G3a, mild to moderate impairment; G3b, moderate to severe impairment; G4, severe impairment, based on estimated glomerular filtration rate (eGFR; ≥90, 60-89, 45-59, 30-44, 15-29 mL/min/1.73 m 2 , respectively). While luseogliflozin pharmacokinetics were similar for patients across all renal function groups, the increase in plasma concentration was slightly slower and maximum concentration was slightly reduced in the lower eGFR groups compared with the other groups. However, luseogliflozin pharmacodynamics were affected by the severity of renal impairment. Urinary glucose excretion (UGE) increased in all groups relative to baseline levels, but the degree of UGE increase was smaller in the lower eGFR groups. Moreover, plasma glucose AUC changes from baseline tended to be smaller in the lower eGFR groups. No clear trends were observed between eGFR and incidence, type, or severity of adverse events. Thus, luseogliflozin administration should be carefully considered, as patients with renal impairment may show an insufficient response to treatment. © 2018 The Authors. Clinical Pharmacology in Drug Development Published by Wiley Periodicals, Inc. on behalf of The American College of Clinical Pharmacology.

  3. Accessory renal arteries: Prevalence in resistant hypertension and an important role in nonresponse to radiofrequency renal denervation

    Energy Technology Data Exchange (ETDEWEB)

    VonAchen, Paige [Minneapolis Heart Institute and Foundation at Abbott Northwestern Hospital, Minneapolis, MN (United States); Hamann, Jason [Boston Scientific Corporation, Maple Grove, MN (United States); Houghland, Thomas; Lesser, John R.; Wang, Yale; Caye, David; Rosenthal, Kristi; Garberich, Ross F. [Minneapolis Heart Institute and Foundation at Abbott Northwestern Hospital, Minneapolis, MN (United States); Daniels, Mary [Vital Images/Toshiba, Minnetonka, MN (United States); Schwartz, Robert S., E-mail: rss@rsschwartz.com [Minneapolis Heart Institute and Foundation at Abbott Northwestern Hospital, Minneapolis, MN (United States)

    2016-10-15

    Objective: The aim of this study was to understand the role of accessory renal arteries in resistant hypertension, and to establish their role in nonresponse to radiofrequency renal denervation (RDN) procedures. Background: Prior studies suggest a role for accessory renal arteries in hypertensive syndromes, and recent clinical trials of renal denervation report that these anomalies are highly prevalent in resistant hypertension. This study evaluated the relationships among resistant hypertension, accessory renal arteries, and the response to radiofrequency (RF) renal denervation. Methods: Computed Tomography Angiography (CTA) and magnetic resonance imaging (MRI) scans from 58 patients with resistant hypertension undergoing RF renal denervation (RDN) were evaluated. Results were compared with CT scans in 57 healthy, normotensive subjects undergoing screening as possible renal transplant donors. All scans were carefully studied for accessory renal arteries, and were correlated with long term blood pressure reduction. Results: Accessory renal arteries were markedly more prevalent in the hypertensive patients than normotensive renal donors (59% vs 32% respectively, p = 0.004). RDN had an overall nonresponse rate of 29% (response rate 71%). Patients without accessory vessels had a borderline higher response rate to RDN than those with at least one accessory vessel (83% vs 62% respectively, p = 0.076) and a higher RDN response than patients with untreated accessory arteries (83% vs 55%; p = 0.040). For accessory renal arteries and nonresponse, the sensitivity was 76%, specificity 49%, with positive and negative predictive values 38% and 83% respectively. Conclusions: Accessory renal arteries were markedly over-represented in resistant hypertensives compared with healthy controls. While not all patients with accessory arteries were nonresponders, nonresponse was related to both the presence and non-treatment of accessory arteries. Addressing accessory renal arteries in

  4. Accessory renal arteries: Prevalence in resistant hypertension and an important role in nonresponse to radiofrequency renal denervation

    International Nuclear Information System (INIS)

    VonAchen, Paige; Hamann, Jason; Houghland, Thomas; Lesser, John R.; Wang, Yale; Caye, David; Rosenthal, Kristi; Garberich, Ross F.; Daniels, Mary; Schwartz, Robert S.

    2016-01-01

    Objective: The aim of this study was to understand the role of accessory renal arteries in resistant hypertension, and to establish their role in nonresponse to radiofrequency renal denervation (RDN) procedures. Background: Prior studies suggest a role for accessory renal arteries in hypertensive syndromes, and recent clinical trials of renal denervation report that these anomalies are highly prevalent in resistant hypertension. This study evaluated the relationships among resistant hypertension, accessory renal arteries, and the response to radiofrequency (RF) renal denervation. Methods: Computed Tomography Angiography (CTA) and magnetic resonance imaging (MRI) scans from 58 patients with resistant hypertension undergoing RF renal denervation (RDN) were evaluated. Results were compared with CT scans in 57 healthy, normotensive subjects undergoing screening as possible renal transplant donors. All scans were carefully studied for accessory renal arteries, and were correlated with long term blood pressure reduction. Results: Accessory renal arteries were markedly more prevalent in the hypertensive patients than normotensive renal donors (59% vs 32% respectively, p = 0.004). RDN had an overall nonresponse rate of 29% (response rate 71%). Patients without accessory vessels had a borderline higher response rate to RDN than those with at least one accessory vessel (83% vs 62% respectively, p = 0.076) and a higher RDN response than patients with untreated accessory arteries (83% vs 55%; p = 0.040). For accessory renal arteries and nonresponse, the sensitivity was 76%, specificity 49%, with positive and negative predictive values 38% and 83% respectively. Conclusions: Accessory renal arteries were markedly over-represented in resistant hypertensives compared with healthy controls. While not all patients with accessory arteries were nonresponders, nonresponse was related to both the presence and non-treatment of accessory arteries. Addressing accessory renal arteries in

  5. [Nursing care in fluorescein angiography].

    Science.gov (United States)

    Santos-Blanco, Feliciano

    2008-01-01

    Fluoresceinic angiography of the ocular fundus is a diagnostic technique to study retinal and choroidal circulation. This technique consists of parenteral administration of 500 mg of sodium fluorescein 10% and photographing the fluorescence in the eye vessels. Although this substance is fairly safe, it may also produce mild, moderate or severe local and/or general adverse reactions. The nursing process is routinely used in hospital units but not always in outpatient clinics, even through the use of invasive procedures with intravenous medication administration is common. Therefore, nurses, as those reponsible for intravenous administration, should use the nursing process to guarantee the quality of care required by the patient. To do this, we describe an individualized care plan based on evaluation by Marjorie Gordon's functional health patterns, NANDA's nursing diagnoses Taxonomy II, Nursing Outcomes Classification (NOC), Nursing Interventions Classifications (NIC) and potential complications of the procedure.

  6. Angiography of primary bone tumors

    International Nuclear Information System (INIS)

    Keyl, W.; Kunkel, B.

    1982-01-01

    To determine the type of a tumour by means of angiography is problematical. Considering that tumour-simulating lesions (myositis ossificans, modular synoritis) can also show pathological blood vessel formations and AV-shunts the interpretation of vessel-architectonic criteria must be done very carefully. The finding of some individual signs of malignancy does not justify the diagnosis of ''malignant tumour''. Only the ''anarchic vessel picture'' (Freyschmidt) with changing caliber, corkscrew vessels, interrupted vessels, unregular tumour colouring, arteria-venous shunts and possibly also tumour invasion into vessels makes a malignant process very likely. The absence of these criteria, however, does not exclude malignancy. Non-vascularised malignant tumours can only lead to a displacement of vessels without an angiographic proof of the tumour itself. (orig./APR) [de

  7. Coronary MR angiography: current status

    International Nuclear Information System (INIS)

    Danias, P.G.; Manning, W.J.

    2000-01-01

    Since first described in the early 1990s, coronary magnetic resonance angiography (MRA) has evolved as a promising noninvasive modality for imaging of the coronary arteries and evaluation of coronary artery disease. Despite technical limitations, coronary MRA has established value for imaging of anomalous coronary arteries and assessment of bypass graft patency. Current research focuses on the development of optimal respiratory compensation strategies, improved spatial and temporal resolution and faster acquisition of image data. The accurate detection of stenoses and assessment of the severity of coronary atherosclerosis is presently being evaluated with large multi-center studies. With further technique enhancements and more clinical experience, coronary MRA is likely to become the dominant noninvasive modality in clinical cardiology. (orig.) [de

  8. Computer assisted radionuclide angiography to confirm reversible ischemic cerebral dysfunction

    International Nuclear Information System (INIS)

    Buell, U.; Lanksch, W.; Tosch, U.; Kleinhans, E.; Steinhoff, H.

    1982-01-01

    Computer assisted radionuclide angiography (CARNA) was employed in patients with transient ischemic attack (TIA) or prolonged reversible ischemic neurologic deficit (PRIND) to establish the sensitivity of CARNA in detecting and quantifying changes of cerebral perfusion in such selected patients. Moreover, results of CARNA were compared with findings of cranial radiographic angiography (RGA) to obtain data on combined sensitivities of these methods. CARNA may be the preferred noninvasive procedure employed because it detects and quantifies the vascular supply disorder in patients with TIA and PRIND. If no computer assistance is used to evaluate cranial radionuclide angiography, results are considerable less accurate. Specifity of CARNA is 84.6%. If CARNA is negative (25.2% in TIA; 12.7% in PRIND), a further method must be employed to confirm the cranial vascular origin of the attack. This may be RGA in TIA and transmission computed axial tomography (T-CAT) T-CAT in PRIND. This diagnos - tic sequence lead to 92.4% true positive in TIA and to 93.2% true positives in PRIND

  9. Understanding the basic concepts of CO2 angiography

    Science.gov (United States)

    Zannoli, Romano; Bianchini, David; Rossi, Pier Luca; Caridi, James G.; Corazza, Ivan

    2016-11-01

    The diagnostic quality of carbon dioxide angiography depends both on optimal setting of radiological aspects (X-ray emission and image post-processing) and on the mechanical behavior of the injected gas bubbles. The gas behavior differs in large cavities (d > 12 mm), medium sized vessels (d > 6 mm), and small diameter vessels (d rules governing the phenomenon in the particular situation. In most cases, it is impossible to fill a vessel completely with gas, and to obtain an adequate angiogram, the gas volume and injection pressure must be properly selected, patient's position must be adjusted and radiological image optimization algorithms, like Digital Subtraction Angiography (DSA) and stacking, must be applied. In this optimization process, the cultural and practical intervention of a medical physicist is fundamental. Obtaining a good quality CO2 angiogram is not only a matter of medical operator experience or radiological system performance, but involves matching a wide knowledge of medical physics to particular pathophysiological conditions and to unusual measurement tests. Most medical physicists are used to dealing mainly with radiological problems, and other physical aspects are considered beyond their interest. In CO2 angiography, non-radiological aspects strongly interfere with radiological issues and an optimal result can only be obtained by tackling the two simultaneously.

  10. Evaluation of renal artery and renal masses using enhanced dynamic MRI. Three-dimensional volumetric interpolated breath-hold examination

    International Nuclear Information System (INIS)

    Ishikawa, Aimi; Kakizaki, Dai; Ito, Naoki; Shindou, Hiroaki; Ozuki, Taizou; Abe, Kimihiko; Sasaki, Kazuyoshi; Katsuyama, Hiroaki

    2003-01-01

    The purpose of this study was to evaluate of three-dimensional volumetric interpolated breathhold examination (3D-VIBE) for imaging renal arteries in renal tumor surgery. Twenty four patients to evaluate renal arteries, and 30 patients for staging of renal tumors. For evaluation of renal arteries, the number of renal arteries and secondary branches, and the RA ratio (renal artery diameter per aorta diameter) were investigated. For tumor evaluation, we investigated T factor and presence and condition of tumor capsule, 3D-VIBE was performed with a MAGNETOM Symphony (Siemens, Erlangen, Germany). Before the dynamic study, we measured renal artery acquisition time with 1 ml of contrast material (Gd-DTPA) and 20 ml of physiological saline solution injected into a hand vein at a rate of 3 ml/sec using an automatic injector. The first phase was set for arrival of the Gd-DTPA at the renal artery, the 2nd for 40 sec after the 1st phase, and the 3rd 180 sec after injection. Then we started scanning with 19 ml of Gd-DTPA and 20 ml of physiological saline solution. Maximum intensity projection (MIP) and multiplanar reconstruction (MFR) were reconstructed by the image data set. All renal arteries were correctly counted In one case, a branch of the superior mesenteric artery (SMA) was mistaken for a renal artery, but correctly identified using a stereo view. The rate of depiction of secondary branches was 86% compared with RA ratio which was significantly smaller than on aortic angiography (p<0.05). The findings for 5 tumors were confirmed by CT, but differed pathologically. We believe 3D-VIBE is useful dynamic CT for evaluation of renal arteries and preoperative classification of renal tumors. (author)

  11. Computed tomography versus invasive coronary angiography

    DEFF Research Database (Denmark)

    Napp, Adriane E.; Haase, Robert; Laule, Michael

    2017-01-01

    Objectives: More than 3.5 million invasive coronary angiographies (ICA) are performed in Europe annually. Approximately 2 million of these invasive procedures might be reduced by noninvasive tests because no coronary intervention is performed. Computed tomography (CT) is the most accurate...... angiography (ICA) is the reference standard for detection of CAD.• Noninvasive computed tomography angiography excludes CAD with high sensitivity.• CT may effectively reduce the approximately 2 million negative ICAs in Europe.• DISCHARGE addresses this hypothesis in patients with low-to-intermediate pretest...

  12. Digital subtraction angiography for breast cancer

    International Nuclear Information System (INIS)

    Tsurumi, Kiyohiko; Okuyama, Nobuo

    1987-01-01

    We performed digital subtraction angiography (DSA) on 42 patients with breast diseases to investigate its efficiency. As a result we came to the following conclusions: 1. The sensitivity was well evaluated in intraarterial digital subtraction angiography (IA-DSA) of breast. 2. IA-DSA could diagnose difficult cases like cancer which had undergone augmentation mammoplasty, or like Paget's disease and others. 3. DSA was a safe examination method. 4. The sensitivity of IA-DSA of breast cancer is superior to intravenous digital subtraction angiography (IV-DSA). (author)

  13. Imaging of the digital arteries: Digital subtraction angiography versus conventional angiography

    International Nuclear Information System (INIS)

    Menanteau, B.P.; Treutenaere, J.M.; Marcus, C.; Ladam, V.; Gausserand, F.

    1986-01-01

    The authors report their experience with the use of digital subtraction angiography (DSA) and conventional angiography of the hand. Of the 95 patients in the study group, 80 underwent conventional angiography and 15 underwent DSA. They analyzed the studies with regard to the type and amount of contrast agent used, the number of radiographs needed, and the diagnostic quality of the images. Conventional angiography often requires general anesthesia, magnification, and pharmaco-angiographic techniques to improve the image-based diagnosis. In comparison with conventional angiography, intraarterial DSA is characterized by improved contrast sensitivity and inferior spatial resolution. However, DSA provides images as acceptable as those of conventional angiography. Smaller catheters can be used, and the examination is performed under local anesthesia. The authors conclude that intraarterial DSA is now the technique of choice for examining patients with chronic ischemia of the hand

  14. Three-dimensional contrast-enhanced magnetic-resonance angiography of the renal arteries: Interindividual comparison of 0.2 mmol/kg gadobutrol at 1.5 T and 0.1 mmol/kg gadobenate dimeglumine at 3.0 T

    International Nuclear Information System (INIS)

    Attenberger, Ulrike I.; Wintersperger, Bernd J.; Sourbron, Steven P.; Reiser, Maximilian F.; Michaely, Henrik J.; Schoenberg, Stefan O.; Lodemann, Klaus-Peter

    2008-01-01

    The purpose was to evaluate the image quality of high-spatial resolution MRA of the renal arteries at 1.5 T after contrast-agent injection of 0.2 mmol/kg body weight (BW) in an interindividual comparison to 3.0 T after contrast-agent injection of 0.1 mmol/kg BW contrast agent (CA). After IRB approval and informed consent, 40 consecutive patients (25 men, 15 women; mean age 53.9 years) underwent MRA of the renal arteries either at a 1.5-T MR system with 0.2 mmol/kg BW gadobutrol or at a 3.0-T MR scanner with 0.1 mmol/kg BW gadobenate dimeglumine used as CA in a randomized order. A constant volume of 15 ml of these contrast agents was applied. The spatial resolution of the MRA sequences was 1.0 x 0.8 x 1.0 mm 3 at 1.5 T and 0.9 x 0.8 x 0.9 mm 3 at 3.0 T, which was achieved by using parallel imaging acceleration factors of 2 at 1.5 T and 3 at 3.0 T, respectively. Two radiologists blinded to the administered CA and the field strength assessed the i