WorldWideScience

Sample records for selected dc tests

  1. Test Results of Selected Commercial DC/DC Converters under Cryogenic Temperatures - A Digest

    Patterson, Richard; Hammoud, Ahmad

    2010-01-01

    DC/DC converters are widely used in space power systems in the areas of power management and distribution, signal conditioning, and motor control. Design of DC/DC converters to survive cryogenic temperatures will improve the power system performance, simplify design, and reduce development and launch costs. In this work, the performance of nine COTS modular, low-tomedium power DC/DC converters was investigated under cryogenic temperatures. The converters were evaluated in terms of their output regulation, efficiency, and input and output currents. At a given temperature, these properties were obtained at various input voltages and at different load levels. A summary on the performance of the tested converters was given. More comprehensive testing and in-depth analysis of performance under long-term exposure to extreme temperatures are deemed necessary to establish the suitability of these and other devices for use in the harsh environment of space exploration missions.

  2. Design and Testing of Boost Type DC/DC Converter for DC Motor Control Applications

    Samman, Faizal Arya; Akil, Yusri Syam; Noor, Nirwan A.

    2017-01-01

    in The Proceeding of The 2nd International Symposium on Smart Material and Mechatronics 2015 This paper presents the design and testing of a boost type DC/DC converter circuit, which can be used for DC motor control applications. The Boost converter is designed using DC chopper and DC chopper cascade configurations. The experimental setup was made by connecting the boost converter circuit with four types of DC motor, i.e. self-excited DC motor shunt, series, compound and separately exci...

  3. Selection of DC/DC converter for offshore wind farms with MVDC power collection

    Dincan, Catalin Gabriel; Kjær, Philip Carne; Chen, Yu-Hsing

    2017-01-01

    Four DC/DC converters are analyzed and compared with respects to availability, efficiency, ratings, repair costs and power density. Intended application is offshore wind farms with MVDC power collection. The selected topology is a new series resonant converter, which offers 99% efficiency across...

  4. High power density dc/dc converter: Selection of converter topology

    Divan, Deepakraj M.

    1990-01-01

    The work involved in the identification and selection of a suitable converter topology is described. Three new dc/dc converter topologies are proposed: Phase-Shifted Single Active Bridge DC/DC Converter; Single Phase Dual Active Bridges DC/DC Converter; and Three Phase Dual Active Bridges DC/DC Converter (Topology C). The salient features of these topologies are: (1) All are minimal in structure, i.e., each consists of an input and output bridge, input and output filter and a transformer, all components essential for a high power dc/dc conversion process; (2) All devices of both the bridges can operate under near zero-voltage conditions, making possible a reduction of device switching losses and hence, an increase in switching frequency; (3) All circuits operate at a constant frequency, thus simplifying the task of the magnetic and filter elements; (4) Since, the leakage inductance of the transformer is used as the main current transfer element, problems associated with the diode reverse recovery are eliminated. Also, this mode of operation allows easy paralleling of multiple modules for extending the power capacity of the system; (5) All circuits are least sensitive to parasitic impedances, infact the parasitics are efficently utilized; and (6) The soft switching transitions, result in low electromagnetic interference. A detailed analysis of each topology was carried out. Based on the analysis, the various device and component ratings for each topology operating at an optimum point, and under the given specifications, are tabulated and discussed.

  5. High torque DC motor fabrication and test program

    Makus, P.

    1976-01-01

    The testing of a standard iron and standard alnico permanent magnet two-phase, brushless dc spin motor for potential application to the space telescope has been concluded. The purpose of this study was to determine spin motor power losses, magnetic drag, efficiency and torque speed characteristics of a high torque dc motor. The motor was designed and built to fit an existing reaction wheel as a test vehicle and to use existing brass-board commutation and torque command electronics. The results of the tests are included in this report.

  6. Drilling and testing specifications for RRL-6, RRL-14, RRL-15 and DC-3

    Moak, D.J.

    1982-07-01

    RRL-6, RRL-14, RRL-15, and DC-3 will provide data for characterization of the stratigraphy and intraflow structures in the Reference Repository Location. This test specification includes details for the drilling and testing of the boreholes. It includes the predicted stratigraphy, the drilling requirements, description of tests to be conducted, intervals selected for hydrologic testing and a schedule of the drilling and testing activities. 14 refs., 8 figs., 12 tabs

  7. Summary of electric vehicle dc motor-controller tests

    Mcbrien, E. F.; Tryon, H. B.

    1982-01-01

    The differences in the performance of dc motors are evaluated when operating with chopper type controllers, and when operating on direct current. The interactions between the motor and the controller which cause these differences are investigated. Motor-controlled tests provided some of the data the quantified motor efficiency variations for both ripple free and chopper modes of operation.

  8. Tests on conducted electrical noise on a storage ring dc-dc converter cabinet

    Carwardine, J.J.

    1994-01-01

    Electrical noise is produced by switching transients in the power supply converters which excite resonances formed by stray capacitance and cable inductance. This noise is present not only on the load cables, but also on ground cables of the magnet and of the converter cabinet. Since there will eventually be a large number of cabinets running at one time, tests were carried out to characterize the noise and to investigate possible techniques for reducing the levels. The tests were carried out on the test girder and converter cabinet set up in 412 area. There were four magnets installed on the girder -- two 0.5m quadrupoles, a 0.8m quadrupole, and a sextupole. These tests were carried out on one of the 0.5m quadrupoles. It should be noted that with this setup, the raw dc power was supplied at around 70V. In the final configuration, a 0.5m quad will be fed from a 40V raw supply. Consequently, the switching transients observed during the tests are likely to be higher than will occur in reality. Noise currents contain two main components: a low frequency component at around 50kHz, and a higher frequency component at around lMHz. It is the latter component which is of primary concern. Currents measured on the dc load cables typically were around one ampere, while currents into the building ground system were only a few tens of milliamps. Several methods were used to try reducing the noise currents, but only the addition of a series impedance was successful -- other methods either had no effect or increased the ground currents

  9. Simulating and Testing a DC-DC Half-Bridge SLR Converter

    2013-06-01

    future pulse power demands with ship power, a large bank of capacitors or similar rapid discharge source is required. If capacitors are charged...Single Pulsed Avalanche Energy (j) I" Avalanche Current (i) E,, Repetilive Avalanche Energy (i) dv/dt Peak Diode Recovery dv/dt ® Po Total Power...SLR), battery charging, DC-DC, pulse power, power electronics, SLR converter 15. NUMBER OF PAGES 119 16. PRICE CODE 17. SECURITY CLASSIFICATION

  10. Wild Carrot Differentiation in Europe and Selection at DcAOX1 Gene?

    Tânia Nobre

    Full Text Available By definition, the domestication process leads to an overall reduction of crop genetic diversity. This lead to the current search of genomic regions in wild crop relatives (CWR, an important task for modern carrot breeding. Nowadays massive sequencing possibilities can allow for discovery of novel genetic resources in wild populations, but this quest could be aided by the use of a surrogate gene (to first identify and prioritize novel wild populations for increased sequencing effort. Alternative oxidase (AOX gene family seems to be linked to all kinds of abiotic and biotic stress reactions in various organisms and thus have the potential to be used in the identification of CWR hotspots of environment-adapted diversity. High variability of DcAOX1 was found in populations of wild carrot sampled across a West-European environmental gradient. Even though no direct relation was found with the analyzed climatic conditions or with physical distance, population differentiation exists and results mainly from the polymorphisms associated with DcAOX1 exon 1 and intron 1. The relatively high number of amino acid changes and the identification of several unusually variable positions (through a likelihood ratio test, suggests that DcAOX1 gene might be under positive selection. However, if positive selection is considered, it only acts on some specific populations (i.e. is in the form of adaptive differences in different population locations given the observed high genetic diversity. We were able to identify two populations with higher levels of differentiation which are promising as hot spots of specific functional diversity.

  11. The high current test facility injector operation to 40 mA dc

    Ungrin, J.; Ormrod, J.H.; Michel, W.L.

    1976-01-01

    The high current test facility injector is a 750 keV proton accelerator designed to investigate the problems involved in the acceleration of intense dc proton beams. The performance of the injector and the experience gained in operation with dc beams up to 40 mA are described. (author)

  12. Design, construction and testing of a DC bioeffects test enclosure for small animals. Final report

    Frazier, M J; Preache, M M

    1980-11-01

    This final report describes both the engineering development of a DC bioeffects test enclosure for small laboratory animals, and the biological protocol for the use of such enclosures in the testing of animals to determine possible biological effects of the environment associated with HVDC transmission lines. The test enclosure which has been designed is a modular unit, which will house up to eight rat-sized animals in individual compartments. Multiple test enclosures can be used to test larger numbers of animals. A prototype test enclosure has been fabricated and tested to characterize its electrical performance characteristics. The test enclosure provides a simulation of the dominant environment associated with HVDC transmission lines; namely, a static electric field and an ion current density. A biological experimental design has been developed for assessing the effects of the dominant components of the HVDC transmission line environment.

  13. Receiver Test Selection Criteria

    2015-03-12

    The DOT requests that GPS manufacturers submit receivers for test in the following TWG categories: - Aviation (non-certified), cellular, general location/navigation, high precision, timing, networks, and space-based receivers - Each receiver should b...

  14. Acoustic Noise Alters Selective Attention Processes as Indicated by Direct Current (DC Brain Potential Changes

    Karin Trimmel

    2014-09-01

    Full Text Available Acoustic environmental noise, even of low to moderate intensity, is known to adversely affect information processing in animals and humans via attention mechanisms. In particular, facilitation and inhibition of information processing are basic functions of selective attention. Such mechanisms can be investigated by analyzing brain potentials under conditions of externally directed attention (intake of environmental information versus internally directed attention (rejection of environmental stimuli and focusing on memory/planning processes. This study investigated brain direct current (DC potential shifts—which are discussed to represent different states of cortical activation—of tasks that require intake and rejection of environmental information under noise. It was hypothesized that without background noise rejection tasks would show more positive DC potential changes compared to intake tasks and that under noise both kinds of tasks would show positive DC shifts as an expression of cortical inhibition caused by noise. DC potential shifts during intake and rejection tasks were analyzed at 16 standard locations in 45 persons during irrelevant speech or white noise vs. control condition. Without noise, rejection tasks were associated with more positive DC potential changes compared to intake tasks. During background noise, however, this difference disappeared and both kinds of tasks led to positive DC shifts. Results suggest—besides some limitations—that noise modulates selective attention mechanisms by switching to an environmental information processing and noise rejection mode, which could represent a suggested “attention shift”. Implications for fMRI studies as well as for public health in learning and performance environments including susceptible persons are discussed.

  15. Acoustic noise alters selective attention processes as indicated by direct current (DC) brain potential changes.

    Trimmel, Karin; Schätzer, Julia; Trimmel, Michael

    2014-09-26

    Acoustic environmental noise, even of low to moderate intensity, is known to adversely affect information processing in animals and humans via attention mechanisms. In particular, facilitation and inhibition of information processing are basic functions of selective attention. Such mechanisms can be investigated by analyzing brain potentials under conditions of externally directed attention (intake of environmental information) versus internally directed attention (rejection of environmental stimuli and focusing on memory/planning processes). This study investigated brain direct current (DC) potential shifts-which are discussed to represent different states of cortical activation-of tasks that require intake and rejection of environmental information under noise. It was hypothesized that without background noise rejection tasks would show more positive DC potential changes compared to intake tasks and that under noise both kinds of tasks would show positive DC shifts as an expression of cortical inhibition caused by noise. DC potential shifts during intake and rejection tasks were analyzed at 16 standard locations in 45 persons during irrelevant speech or white noise vs. control condition. Without noise, rejection tasks were associated with more positive DC potential changes compared to intake tasks. During background noise, however, this difference disappeared and both kinds of tasks led to positive DC shifts. Results suggest-besides some limitations-that noise modulates selective attention mechanisms by switching to an environmental information processing and noise rejection mode, which could represent a suggested "attention shift". Implications for fMRI studies as well as for public health in learning and performance environments including susceptible persons are discussed.

  16. Possibilities and testing of CPRNG in block cipher mode of operation PM-DC-LM

    Zacek, Petr; Jasek, Roman; Malanik, David [Faculty of applied Informatics, Tomas Bata University in Zlin, Zlin, Czech Republic zacek@fai.utb.cz, jasek@fai.utb.cz, dmalanik@fai.utb.cz (Czech Republic)

    2016-06-08

    This paper discusses the chaotic pseudo-random number generator (CPRNG), which is used in block cipher mode of operation called PM-DC-LM. PM-DC-LM is one of possible subversions of general PM mode. In this paper is not discussed the design of PM-DC-LM, but only CPRNG as a part of it because designing is written in other papers. Possibilities, how to change or to improve CPRNG are mentioned. The final part is devoted for a little testing of CPRNG and some testing data are shown.

  17. Possibilities and testing of CPRNG in block cipher mode of operation PM-DC-LM

    Zacek, Petr; Jasek, Roman; Malanik, David

    2016-06-01

    This paper discusses the chaotic pseudo-random number generator (CPRNG), which is used in block cipher mode of operation called PM-DC-LM. PM-DC-LM is one of possible subversions of general PM mode. In this paper is not discussed the design of PM-DC-LM, but only CPRNG as a part of it because designing is written in other papers. Possibilities, how to change or to improve CPRNG are mentioned. The final part is devoted for a little testing of CPRNG and some testing data are shown.

  18. Possibilities and testing of CPRNG in block cipher mode of operation PM-DC-LM

    Zacek, Petr; Jasek, Roman; Malanik, David

    2016-01-01

    This paper discusses the chaotic pseudo-random number generator (CPRNG), which is used in block cipher mode of operation called PM-DC-LM. PM-DC-LM is one of possible subversions of general PM mode. In this paper is not discussed the design of PM-DC-LM, but only CPRNG as a part of it because designing is written in other papers. Possibilities, how to change or to improve CPRNG are mentioned. The final part is devoted for a little testing of CPRNG and some testing data are shown.

  19. Test and evaluation of load converter topologies used in the Space Station Freedom power management and distribution dc test bed

    Lebron, Ramon C.; Oliver, Angela C.; Bodi, Robert F.

    1991-01-01

    Power components hardware in support of the Space Station freedom dc Electric Power System were tested. One type of breadboard hardware tested is the dc Load Converter Unit, which constitutes the power interface between the electric power system and the actual load. These units are dc to dc converters that provide the final system regulation before power is delivered to the load. Three load converters were tested: a series resonant converter, a series inductor switch-mode converter, and a switching full-bridge forward converter. The topology, operation principles, and test results are described, in general. A comparative analysis of the three units is given with respect to efficiency, regulation, short circuit behavior (protection), and transient characteristics.

  20. Borehole DC-12 hydrostratigraphic chart

    Gephart, R.E.

    1981-09-01

    This hydrostratigraphic chart identifies the basic stratigraphy and preliminary hydrologic testing results for Borehole DC-12. This borehole was cored through the Saddle Mountains and Wanapum basalt formations and into the Grande Ronde. Selected zones were hydrologically tested during coring

  1. Borehole DC-14 hydrostratigraphic chart

    Gephart, R.E.

    1981-09-01

    This hydrostratigraphic chart identifies the basic stratigraphy and preliminary hydrologic testing results for Borehole DC-14. This borehole was cored through the Saddle Mountains and Wanapum basalt formations and into the Grande Ronde. Selected zones were hydrologically tested during coring

  2. Borehole DC-15 hydrostratigraphic chart

    Gephart, R.E.

    1981-09-01

    This hydrostratigraphic chart identifies the basic stratigraphy and preliminary hydrologic testing results for Borehole DC-15. This borehole was cored through the Saddle Mountains and Wanapum basalt formations and into the Grande Ronde. Selected zones were hydrologically tested during coring

  3. Selective harmonic elimination strategy in eleven level inverter for PV system with unbalanced DC sources

    Ghoudelbourk, Sihem.; Dib, D.; Meghni, B.; Zouli, M.

    2017-02-01

    The paper deals with the multilevel converters control strategy for photovoltaic system integrated in distribution grids. The objective of the proposed work is to design multilevel inverters for solar energy applications so as to reduce the Total Harmonic Distortion (THD) and to improve the power quality. The multilevel inverter power structure plays a vital role in every aspect of the power system. It is easier to produce a high-power, high-voltage inverter with the multilevel structure. The topologies of multilevel inverter have several advantages such as high output voltage, lower total harmonic distortion (THD) and reduction of voltage ratings of the power semiconductor switching devices. The proposed control strategy ensures an implementation of selective harmonic elimination (SHE) modulation for eleven levels. SHE is a very important and efficient strategy of eliminating selected harmonics by judicious selection of the firing angles of the inverter. Harmonics elimination technique eliminates the need of the expensive low pass filters in the system. Previous research considered that constant and equal DC sources with invariant behavior; however, this research extends earlier work to include variant DC sources, which are typical of lead-acid batteries when used in system PV. This Study also investigates methods to minimize the total harmonic distortion of the synthesized multilevel waveform and to help balance the battery voltage. The harmonic elimination method was used to eliminate selected lower dominant harmonics resulting from the inverter switching action.

  4. Upgrade of DC power supply system in ITER CS model coil test facility

    Shimono, Mitsugu; Uno, Yasuhiro; Yamazaki, Keita; Kawano, Katsumi; Isono, Takaaki

    2014-03-01

    Objective of the ITER CS Model Coil Test Facility is to evaluate a large scale superconducting conductor for fusion using the Central Solenoid (CS) Model Coil, which can generate a 13T magnetic field in the inner bore with a 1.5 m diameter. The facility is composed of a helium refrigerator / liquefier system, a DC power supply system, a vacuum system and a data acquisition system. The DC power supply system supplies currents to two superconducting coils, the CS Model Coil and an insert coil. A 50-kA DC power supply is installed for the CS Model Coil and two 30 kA DC power supplies are installed for an insert coil. In order to evaluate superconducting performance of a conductor used for ITER Toroidal Field (TF) coils whose operating current is 68 kA, the line for an insert coil is upgraded. A 10 kA DC power supply was added, DC circuit breakers were upgraded, bus bars and current measuring instrument were replaced. In accordance to the upgrade, operation manual was revised. (author)

  5. The first DC performance test and analysis of CC conductor short sample at ASIPP conductor test facility

    Shi Yi; Wu Yu; Liu Huajun; Long Feng; Qian Li; Ren Zhibin; Li Shaolei; Liu Bo; Chen Jinglin

    2012-01-01

    Highlights: ► In this study the first DC performance experiments of ITER correction coil conductor short sample have been carried out in ASIPP test facility. ► A CC conductor short sample was fabricated and tested to confirm the capability of this test facility for qualification tests of CC conductors. ► There is no obvious impact of cycling on DC performance measurement. ► Those measured results of current sharing temperature are in agreement with the expected results from strand scaling - Abstract: The first DC performance experiments of ITER correction coil (CC) conductor short sample have been carried out in the conductor test facility of Institute of Plasma Physics, CAS (ASIPP) in January this year. Those experiments aim to investigate the DC performance of ITER CC conductor. The tested conductor short sample is bended as a half circle with the diameter of 270 mm to meet the background magnetic field shape. The half circle part of sample is longer than the final twist pitch. The current sharing temperature (T cs ) in the 3.86 T external magnetic field (B ex ), ≤12 kA could be measured including the critical current (I c ) run. There is no obvious impact of 1000 cycles on DC performance. Those measured T cs results are in agreement with the expected results from strand scaling.

  6. Establishment of functional requirements to DC-connected wind turbine and their use in concept selection

    Dincan, Catalin Gabriel; Kjær, Philip Carne; Chen, Yu-Hsing

    2017-01-01

    , but they are all still at an immature technology level, as no substantial experience from full-scale detailed design exists. By employing a functional failure mode and effects analysis (F-FMEA) with a decision making tool (Pugh Matrix), the paper presents a structured set of functionalities and design drivers...... required from the turbine DC converter and uses these to compare 6 distinct candidate circuit topologies. The end goal is not to select the best topology, but to narrow down from a vast list of options and give a method that will increase confidence and guide towards the characteristics of reliable design....

  7. Performance Test of the Microwave Ion Source with the Multi-layer DC Break

    Kim, Dae Il; Kwon, Hyeok Jung; Kim, Han Sung; Seol, Kyung Tae; Cho, Yong Sub

    2012-01-01

    A microwave proton source has been developed as a proton injector for the 100-MeV proton linac of the PEFP (Proton Engineering Frontier Project). On microwave ion source, the high voltage for the beam extraction is applied to the plasma chamber, also to the microwave components such as a 2.45GHz magnetron, a 3-stub tuner, waveguides. If microwave components can be installed on ground side, the microwave ion source can be operated and maintained easily. For the purpose, the multi-layer DC break has been developed. A multi-layer insulation has the arrangement of conductors and insulators as shown in the Fig. 1. For the purpose of stable operation as the multi-layer DC break, we checked the radiation of the insulator depending on materials and high voltage test of a fabricated multi-layer insulation. In this report, the details of performance test of the multi-layer DC break will be presented

  8. Primary beam-loading tests on DC-SC photoinjector at Peking University

    Hao Jiankui; Lu Xiangyang; Ding, Yuantao; Quan Shengwen; Huang Senlin; Zhao Kui; Zhang Baocheng; Wang Lifang; Lin Lin; Jiao Fei; Wang Guimei; Xie Datao; Zhu Feng; Xiao Binping; Xiang Rong; Chen Jia'er

    2006-01-01

    The DC-SC photoinjector is a compact electron gun integrating a DC pierce gun with a 1.3 GHz 1+1/2 cell superconducting cavity. A test facility of the DC-SC photoinjector had been installed in Peking University and beam-loading tests at 4.4 K have been finished. To date the gradient of 6 MV/m has been achieved. The maximum energy gain is 1.1 MeV at 4.4 K. With average beam current of 270 μA, the measured rms emittance is about 5 mm mrad at the beam energy of 500 keV. In this paper some of the experimental results are summarized

  9. Influence of DC plasma modification on the selected properties and the geometrical surface structure of polylactide prior to autocatalytic metallization

    Moraczewski, Krzysztof, E-mail: kmm@ukw.edu.pl [Kazimierz Wielki University, Chodkiewicza 30, 85-064 Bydgoszcz (Poland); Rytlewski, Piotr [Kazimierz Wielki University, Chodkiewicza 30, 85-064 Bydgoszcz (Poland); Malinowski, Rafał [Institute for Engineering of Polymer Materials and Dyes, Marii Skłodowskiej-Curie 55, 87-100 Toruń (Poland); Tracz, Adam [Centre for Molecular and Macromolecular Studies of the Polish Academy of Sciences, Sienkiewicza 112, 90-363 Łódź (Poland); Żenkiewicz, Marian [Institute for Engineering of Polymer Materials and Dyes, Marii Skłodowskiej-Curie 55, 87-100 Toruń (Poland)

    2015-03-01

    The paper presents the results of studies to determine the applicability of plasma modification in the process of polylactide (PLA) surface preparation prior to the autocatalytic metallization. The polylactide plasma modification was carried out in an oxygen or nitrogen chemistry. The samples were tested with the following methods: scanning electron microscopy (SEM), atomic force microscopy (AFM), goniometry and electron spectrophotometry (XPS). Scanning electron microscopy and atomic force microscopy images were demonstrated. The results of surface free energy calculations, performed based on the results of the contact angle measurements have been presented. The results of the qualitative (degree of oxidation or nitridation) and quantitative analysis of the chemical composition of the polylactide surface layer have also been described. The results of the studies show that the DC plasma modification performed in the proposed condition is a suitable as a method of surface preparation for the polylactide metallization. - Highlights: • We modified polylactide surface layer with plasma generated in oxygen or nitrogen. • We tested selected properties and surface structure of modified samples. • DC plasma modification can be used to prepare the PLA surface for metallization. • For better results metallization should be preceded by sonication process.

  10. Degradation testing and failure analysis of DC film capacitors under high humidity conditions

    Wang, Huai; Nielsen, Dennis Achton; Blaabjerg, Frede

    2015-01-01

    Metallized polypropylene film capacitors are widely used for high-voltage DC-link applications in power electronic converters. They generally have better reliability performance compared to aluminum electrolytic capacitors under electro-thermal stresses within specifications. However......, the degradation of the film capacitors is a concern in applications exposed to high humidity environments. This paper investigates the degradation of a type of plastic-boxed metallized DC film capacitors under different humidity conditions based on a total of 8700 h of accelerated testing and also post failure...... of interest is also presented. The study enables a better understanding of the humidity-related failure mechanisms and reliability performance of DC film capacitors for power electronics applications....

  11. Preliminary hydrologic testing results: McCoy Canyon flow-top, DC-7, 3410.2-3477.6 feet and DC-8: 3407.0-3480.4 feet

    Jackson, R.L.; Moak, D.J.; Spane, F.A. Jr.

    1982-01-01

    This report describes the hydrologic tests performed for an interflow zone within the Grande Ronde Basalt at Boreholes DC-7/8. The results, along with hydrologic data from several boreholes, will provide input for hydrologic modeling of groundwater flow and solute transport to assess the feasibility of siting a nuclear waste repository beneath the Hanford Site. 7 figs., 1 tab

  12. 50 mm Diameter digital DC/pulse neutron generator for subcritical reactor test

    Li Gang; Zhang Zhongshuai; Chi Qian; Liu Linmao

    2012-01-01

    A 50 mm diameter digital DC/pulse neutron generator was developed with 25 mm ceramic drive-in target neutron tube. It was applied in the subcritical reactor test of China Institute of Atomic Energy (CIAE). The generator can produce neutron in three modes: DC, pulse and multiple pulse. The maximum neutron yield of the generator is 1 × 10 8 n/s, while the maximum pulse frequency is 10 kHz, and the minimum pulse width is 10 μs. As a remote controlled generator, it is small in volume, easy to be connected and controlled. The tested results indicate that penning ion source has the feature of delay time in glow discharge, and it is easier for glow discharge to happen when switching the DC voltage of penning ion source into pulse. According to these two characteristics, the generator has been modified. This improved generator can be used in many other areas including Prompt Gamma Neutron Activation Analysis (PGNAA), neutron testing and experiment.

  13. 50 mm Diameter digital DC/pulse neutron generator for subcritical reactor test

    Li Gang; Zhang Zhongshuai [Northeast Normal University, Changchun 130024 (China); Chi Qian [Guang Hua College of Chang Chun University, Changchun 130117 (China); Liu Linmao, E-mail: ll888@nenu.edu.cn [Northeast Normal University, Changchun 130024 (China)

    2012-11-01

    A 50 mm diameter digital DC/pulse neutron generator was developed with 25 mm ceramic drive-in target neutron tube. It was applied in the subcritical reactor test of China Institute of Atomic Energy (CIAE). The generator can produce neutron in three modes: DC, pulse and multiple pulse. The maximum neutron yield of the generator is 1 Multiplication-Sign 10{sup 8} n/s, while the maximum pulse frequency is 10 kHz, and the minimum pulse width is 10 {mu}s. As a remote controlled generator, it is small in volume, easy to be connected and controlled. The tested results indicate that penning ion source has the feature of delay time in glow discharge, and it is easier for glow discharge to happen when switching the DC voltage of penning ion source into pulse. According to these two characteristics, the generator has been modified. This improved generator can be used in many other areas including Prompt Gamma Neutron Activation Analysis (PGNAA), neutron testing and experiment.

  14. Overview and evolution of the LeRC PMAD DC test bed

    Soeder, James F.; Frye, Robert J.

    1992-01-01

    Since the beginning of the Space Station Freedom Program (SSFP), the Lewis Research Center (LeRC) has been developed electrical power system test beds to support the overall design effort. Through this time, the SSFP has changed the design baseline numerous times, however, the test bed effort has endeavored to track these changes. Beginning in August 1989 with the baseline and an all DC system, a test bed was developed to support the design baseline. The LeRC power measurement and distribution (PMAD) DC test bed and the changes in the restructure are described. The changes included the size reduction of primary power channel and various power processing elements. A substantial reduction was also made in the amount of flight software with the subsequent migration of these functions to ground control centers. The impact of these changes on the design of the power hardware, the controller algorithms, the control software, and a description of their current status is presented. An overview of the testing using the test bed is described, which includes investigation of stability and source impedance, primary and secondary fault protection, and performance of a rotary utility transfer device. Finally, information is presented on the evolution of the test bed to support the verification and operational phases of the SSFP in light of these restructure scrubs.

  15. MPPT algorithm test on a photovoltaic emulating system constructed by a DC power supply and an indoor solar panel

    Zhou, Z.; Holland, P.M.; Igic, P.

    2014-01-01

    Highlights: • A novel PV emulator is constructed by using conventional solar panels with a DC power supply. • The proposed PV emulator is cost-effectiveness, relatively easy implementation. • The proposed PV emulator avoids the bandwidth problem associated with electronics PV emulators. • Indoor testing of MPPT algorithms and power converters avoids the dependency on solar irradiation. • The PV emulating system has been used for testing a P and O MPPT algorithm and a boost dc converter. - Abstract: In this paper a novel photovoltaic (PV) emulating scheme for testing maximum power point tracking (MPPT) algorithms and PV inverters has been proposed. It is constructed by the parallel connection of conventional solar panels with a DC power supply operating in current source mode. The advantages of the proposed scheme are cost-effectiveness, relatively easy implementation and indoor testing of MPPT algorithms and power converters avoiding weather and time of day dependency on solar irradiation levels. Furthermore, the proposed PV emulator avoids the bandwidth problem associated with the dc converter based PV emulating systems. Detailed circuit connection, parameters, electrical characteristics and mathematical model of the PV emulator are presented and discussed. Proposed PV emulating system has been used to test a boost DC/DC converter controlled by Perturb and Observe (P and O) MPPT algorithm. Test results confirmed the effectiveness of the proposed PV emulation system and all achieved results correspond well to the original designed values

  16. The Automated DC Parameter Testing of GaAs MESFETs Using the Singer Automatic Integrated Circuit Test System.

    1980-09-01

    USING THE SINGER AUTOMATIC INTEGRATED CIRCUIT TEST SYSTEM, THOMAS L. HARPER AFIT/EE/GE/80- 7 Ist LT USAF -- -- - - __ AFIT/EE/GE/80-7 THE AUTOMATED DC...THOMAS L. HARPER ist Lt USAF Graduate Electrical Engineering September 1980 it’ Codes A _ _ _ J PREFACE This report is in support of the ongoing effort in...8217.-- I *t -1 ,p - tUel-, ir. ( /.s , j Yf) L) b ..... l P i:. +’ ,T i~: ",,’+l l L V i i ,’b : O Iil r, P V 47 C’+t ( ’ I ViH 47 V ’L 4 £, ,.;l 1 , h

  17. Lifetime test on a high-performance dc microwave proton source

    Sherman, J.D.; Hodgkins, D.J.; Lara, P.D.; Schneider, J.D.; Stevens, R.R. Jr.

    1995-01-01

    Powerful CW proton linear accelerators (100 mA at 0.5--1 GeV) are being proposed for spallation neutron source applications.These production accelerators require high availability and reliability. A microwave proton source, which has already demonstrated several key beam requirements, was operated for one week (170 hours) in a dc mode to test the reliability and lifetime of its plasma generator. The source was operated with 570 W of microwave (2.45 GHz) discharge power and with a 47-kV extraction voltage. This choice of operating parameters gave a proton current density of 250-mA/cm 2 at 83% proton fraction, which is sufficient for a conservative dc injector design. The beam current was 60--65 mA over most of the week, and was sufficiently focused for RFQ injection. Total beam availability, defined as 47-keV beam-on time divided by elapsed time, was 96.2%. Spark downs in the high voltage column and a gas flow control problem caused all the downtime; no plasma generator failures were observed

  18. Selecting Items for Criterion-Referenced Tests.

    Mellenbergh, Gideon J.; van der Linden, Wim J.

    1982-01-01

    Three item selection methods for criterion-referenced tests are examined: the classical theory of item difficulty and item-test correlation; the latent trait theory of item characteristic curves; and a decision-theoretic approach for optimal item selection. Item contribution to the standardized expected utility of mastery testing is discussed. (CM)

  19. GP2 is selectively expressed by small intestinal CD103+CD11b+ cDC

    Müller-Luda, Katarzyna; Ahmadi, Fatemeh; Ohno, Hiroshi

    DC in the small intestine. Moreover, GP2 expressing cDC in the small intestine were dramatically reduced in the setting of intestinal inflammation. We have previously shown that mice with an IRF4 deletion in CD11c+ cells (Cd11c-cre.Irf4 fl/fl mice) have reduced numbers of small intestinal CD103+CD11b+ c......DC. Interesting, we found that GP2+ CD103+CD11b+ cDC were dramatically reduced in these mice. Finally, to address the in vivo role of GP2 expression by cDC, we have generated mice with a selective deletion of GP2 in CD103+CD11b+ cDC (huLangerin-cre.gp2 fl/fl  mice). Results from these ongoing studies...

  20. Volatilization and redox testing in a DC arc melter: FY-93 and FY-94

    Grandy, J.D.; Sears, J.W.; Soelberg, N.R.; Reimann, G.A.; McIlwain, M.E.

    1996-07-01

    The purpose of these experiments was to study the dissolution, retention, volatilization, and trapping of transuranic radionuclide elements (TRUs), mixed fission and activation products, and high vapor pressure metals (HVPMS) during processing in a high temperature arc furnace. In all cases, surrogate elements (lanthanides) were used in place of radioactive ones. The experiments were conducted utilizing a small DC arc melter developed at the Idaho National Engineering Laboratory (INEL) Research Center (IRC). The small arc melter was originally developed in 1992 and has been used previously for waste form studies of iron enriched basalt (IEB) and IEB with zirconium and titanium additions (IEB4). Section 3 contains a description of the small arc melter and its operational capabilities are discussed in Chapter 4. The remainder of the document describes each testing program and then discusses results and findings

  1. Demonstration of AC and DC charge control for the LISA test masses

    Olatunde, Taiwo Janet

    2018-01-01

    Taiwo Olatunde, Stephen Apple, Andrew Chilton, Samantha Parry, Peter Wass, Guido Mueller, John W. Conklin The residual test mass acceleration in LISA must be below 3 fm/s2/√Hz at all frequencies between 0.1 and 3 mHz. Test mass charge coupled with stray electrical potentials and external electromagnetic fields is a well-known source of acceleration noise. LISA Pathfinder uses Hg lamps emitting mostly around 254 nm to discharge the test masses via photoemission, but a future LISA mission launched around 2030 will likely replace the lamps with newer UV LEDs with lower mass, better power efficiency, smaller size and higher bandwidth. This presentation will discuss charge control demonstrated on the torsion pendulum in AC and DC modes at the University of Florida using latest generation UV LEDs producing light at 240 nm with energy above the work function of pure Au. Initial results of Au quantum efficiency measurements (number of emitted electrons per incident photons) which is critical for bi-polar charge control will also be presented.

  2. Design and performance of a 2-megawatt high voltage dc test load

    Horan, D.; Kustom, R.; Ferguson, M.

    1994-01-01

    A high-power water-cooled resistive load which simulates the electrical load characteristics of a high-power klystron, capable of a 2 MW dissipation at 95 kV DC, is designed and installed. The load utilizes wirewound resistor elements suspended inside G-11 insulated tubing contained within a single-wall 316 stainless steel pressure vessel with flanged elliptical heads. The vessel supplies a continuous flow of deionized water. Baffles fabricated from G-10 sheets support the tubing and promote water turbulence to maximize heat removal. A companion oil tank houses resistive filament and mod-anode power supply test loads, plus an electrical interlock system which provides protection from inadequate water flow, excessive oil temperature, and arcing in either the pressure vessel or oil tank. A secondary safety system consists of both hydrostatic and steam pressure relief valves on the pressure vessel. Power supply tests indicate the load simulates the electrical load characteristics of a high-power klystron to a degree sufficient to accurately performance-test the rf high voltage power supplies used at the Advanced Photon Source

  3. Mapping of Ambient Magnetic Fields within Liquid Helium Dewar for Testing of a DC SQUID Magnetometer

    Newhouse, Randal

    2003-01-01

    In an effort to explore the cavity lights phenomenon, Experimental Facilities Department at SLAC is testing a DC SQUID magnetometer. Due to the nature of the SQUID magnetometer and the intended tests, the earth's magnetic field must be negated. It is proposed to reduce ambient fields using bucking coils. First, however, an accurate map of the magnetic field inside the liquid helium Dewar where the experiment is going to take place needed to be made. This map was made using a three-axis fluxgate magnetometer mounted on a 3D positioning device made for this purpose. A ten inch tall volume within the Dewar was measured at data points approximately an inch from each other in all three axes. A LabVEIW program took readings from the magnetometer at 2 ms intervals for 1000 readings in such a way as to eliminate any ambient 60 Hz signals that may be present in the data. This data was stored in spreadsheet format and was analyzed to determine how the magnetic field within the Dewar was changing as a function of position

  4. Test Platform for Advanced Digital Control of Brushless DC Motors (MSFC Center Director's Discretionary Fund)

    Gwaltney, D. A.

    2002-01-01

    A FY 2001 Center Director's Discretionary Fund task to develop a test platform for the development, implementation. and evaluation of adaptive and other advanced control techniques for brushless DC (BLDC) motor-driven mechanisms is described. Important applications for BLDC motor-driven mechanisms are the translation of specimens in microgravity experiments and electromechanical actuation of nozzle and fuel valves in propulsion systems. Motor-driven aerocontrol surfaces are also being utilized in developmental X vehicles. The experimental test platform employs a linear translation stage that is mounted vertically and driven by a BLDC motor. Control approaches are implemented on a digital signal processor-based controller for real-time, closed-loop control of the stage carriage position. The goal of the effort is to explore the application of advanced control approaches that can enhance the performance of a motor-driven actuator over the performance obtained using linear control approaches with fixed gains. Adaptive controllers utilizing an exact model knowledge controller and a self-tuning controller are implemented and the control system performance is illustrated through the presentation of experimental results.

  5. Using built-in functions of Adobe Acrobat Pro DC to help the selection process in systematic reviews of randomised trials.

    Nur, Selin; Adams, Clive E; Brailsford, David F

    2016-02-18

    This letter describes a simple way of using Adobe Acrobat Pro DC to help select and auto-extract data from Portable Document Format (PDFs) of randomised trials in order to assist swift early selection of trials for a systematic review.

  6. Energy Management of a Hybrid AC–DC Micro-Grid Based on a Battery Testing System

    Bo Long

    2015-02-01

    Full Text Available Energy Recovery Battery Testing Systems (ERBTS plays an important role in battery manufacture. The conventional ERBTS configuration contains a fundamental transformer, and a bidirectional Direct Current (DC–DC and Alternating Current (AC–DC converter. All ERBTS are connected in parallel, thus constituting a special and complicated AC micro-grid system. Aiming at addressing their low energy recovery efficiency, complex grid-connected control algorithm issues for islanded detection, and complicated power circuit topology issues, a hierarchical DC-link voltage hybrid AC–DC micro-grid that contains composite energy storing devices is proposed. Moreover, an energy management optimal scheme for the proposed scheme is put forward. The system configuration of the proposed scheme is described in detail. Compared to the conventional scheme, the proposed scheme has the merits of simplified power circuit topology, no need for phase synchronous control, and much higher energy recovery efficiency and reliability. The validity and effectiveness of the proposed technique is verified through numerous experimental results.

  7. Bayesian item selection criteria for adaptive testing

    van der Linden, Willem J.

    1996-01-01

    R.J. Owen (1975) proposed an approximate empirical Bayes procedure for item selection in adaptive testing. The procedure replaces the true posterior by a normal approximation with closed-form expressions for its first two moments. This approximation was necessary to minimize the computational

  8. IGBT Based DC/DC Converter

    M. Akherraz

    1997-12-01

    Full Text Available This paper presents an in-depth analytical and experimental investigation of an indirect DC-DC converter. The DC-AC conversion is a full bridge based on IGBT power modules, and the AC-DC conversion is done via a high  frequency AC link and a first diode bridge. The AC link, which consists of snubbing capacitors and a variable air-gap transformer, is analytically designed to fulfill Zero Voltage commutation requirement. The proposed converter is simulated using PSPICE and a prototype is designed built and tested in the laboratory. PSPICE simulation and experimental results are presented and compared.

  9. Acoustic Noise Alters Selective Attention Processes as Indicated by Direct Current (DC) Brain Potential Changes

    Trimmel, Karin; Schätzer, Julia; Trimmel, Michael

    2014-01-01

    Acoustic environmental noise, even of low to moderate intensity, is known to adversely affect information processing in animals and humans via attention mechanisms. In particular, facilitation and inhibition of information processing are basic functions of selective attention. Such mechanisms can be investigated by analyzing brain potentials under conditions of externally directed attention (intake of environmental information) versus internally directed attention (rejection of environmental ...

  10. Advanced DC/DC converters

    Luo, Fang Lin

    2003-01-01

    DC/DC conversion techniques have undergone rapid development in recent decades. With the pioneering work of these authors, DC/DC converters have now moved into their sixth generation. This book offers a concise, practical presentation of DC/DC converters, summarizing the spectrum of conversion tecnologies and presentingmany new ideas and more than 100 new topologies. Nowhere else in the literature are DC/DC converters so logically sorted and systematically introduced, and nowhere else can readers find detailed information on prototype topologies that represent a major contribution to modern power engineering. More than 320 figures, 60 tables, and 500 formulae facilitate understand and provide precise data.

  11. Sexual selection and hermaphroditic organisms: Testing theory

    Janet L. LEONARD

    2013-08-01

    Full Text Available Sexual selection is widespread if not ubiquitous in hermaphroditic organisms. Although many phenomena that have been described as sexual selection in gonochores, (e.g. harem polygamy, multiple mating, elaborate courtship, even secondary sexual characters can be found in some hermaphrodites, what is more interesting is the ways in which sexual selection in hermaphrodites may differ from dioecious taxa. In hermaphrodites, an individual’s mating success includes its success from both sexual roles. Secondly, in many simultaneously hermaphroditic taxa there is strong evidence of sexual selection and yet the ope­rational sex ratio is 1:1, by definition. Many simultaneous hermaphrodites have elaborate courtship and genital anatomy, suggesting sexual selection plays an important role in reproductive success. Sperm competition and cryptic female choice mean that the number of mates acquired is not necessarily a predictor of reproductive success. Even in simultaneous hermaphrodites with reciprocal mating, variance in reproductive success through the male role and through the female role may differ in a population. Moreover hermaphrodites may choose to emphasize one sexual role over the other. Data suggest that the preferred role varies in hermaphrodites, which creates an opportunity to test fundamental predictions and assumptions of sexual selection theory. Hermaphrodites may vary their emphasis on one sexual role over the other either developmentally or behaviorally in response to environmental or social parameters. How they use this capability in acquiring more or higher quality mates still requires study [Current Zoology 59 (4: 579–588, 2013].

  12. R5 human immunodeficiency virus type 1 with efficient DC-SIGN use is not selected for early after birth in vertically infected children.

    Borggren, Marie; Navér, Lars; Casper, Charlotte; Ehrnst, Anneka; Jansson, Marianne

    2013-04-01

    The binding of human immunodeficiency virus (HIV) to C-type lectin receptors may result in either enhanced trans-infection of T-cells or virus degradation. We have investigated the efficacy of HIV-1 utilization of DC-SIGN, a C-type lectin receptor, in the setting of intrauterine or intrapartum mother-to-child transmission (MTCT). Viruses isolated from HIV-1-infected mothers at delivery and from their vertically infected children both shortly after birth and later during the progression of the disease were analysed for their use of DC-SIGN, binding and ability to trans-infect. DC-SIGN use of a child's earlier virus isolate tended to be reduced as compared with that of the corresponding maternal isolate. Furthermore, the children's later isolate displayed enhanced DC-SIGN utilization compared with that of the corresponding earlier virus. These results were also supported in head-to-head competition assays and suggest that HIV-1 variants displaying efficient DC-SIGN use are not selected for during intrauterine or intrapartum MTCT. However, viruses with increased DC-SIGN use may evolve later in paediatric HIV-1 infections.

  13. The life test of a DC circuit breaker of tokamak device JT-60 for a nuclear fusion research

    Shimada, Ryuichi; Tani, Keiji; Kishimoto, Hiroshi; Tamura, Sanae; Yanabu, Satoru.

    1979-01-01

    In the Tokamak devices for nuclear fusion research, the construction of the current transformer circuits having plasma as the secondary circuit and the change of the primary circuit current are necessary for generating current in the plasma. This is considered to be fairly difficult in practice if conventional methods using capacitor discharge and iron core coils are employed. Considering such circumstances, it was decided for JT-60 to use an air-core current transformer coil and to employ the method of storing energy in the form of current in the coil inductance instead of a capacitor. For this reason, a DC circuit breaker is required to interrupt coil current. The authors improved an AV vacuum breaker, which had been developed as the vacuum breaker of longitudinal magnetic field type applying a magnetic field in parallel with an arc, to get the one for DC circuit for the purpose of applying it to JT-60. In this paper, the operational characteristic of the DC breaker is described, the construction and function of the life test circuit is explained, and the test results are reported. Finally, interruptions of 10,000 times at 20 kA were carried out. It is successful that the restrike of arc occurring during tens of milli-seconds after interruptions was improved to 0.05% or less for 10,000 times operations. Further, it was found that the generation of arc restrike can be reduced practically to zero with two breakers in series. (Wakatsuki, Y.)

  14. DC Brushless Motor Control Design and Preliminary Testing for Independent 4-Wheel Drive Rev-11 Robotic Platform

    Roni Permana Saputra

    2012-03-01

    Full Text Available This paper discusses the design of control system for brushless DC motor using microcontroller ATMega 16 that will be applied to an independent 4-wheel drive Mobile Robot LIPI version 2 (REV-11. The control system consists of two parts which are brushless DC motor control module and supervisory control module that coordinates the desired command to the motor control module. To control the REV-11 platform, supervisory control transmit the reference data of speed and direction of motor to control the speed and direction of each actuator on the platform REV-11. From the test results it is concluded that the designed control system work properly to coordinate and control the speed and direction of motion of the actuator motor REV-11 platform. 

  15. Application of the DC potential drop and the partial unloading methods to fracture mechanics tests

    Heerens, J.; Schwalbe, K.H.; Hellmann, D.; Knaack, J.; Mueller-Roos, J.

    1985-01-01

    The ability of the DC potential drop method and the partial unloading technique to measure crack growth and to detect initation of crack growth has been investigated using a number of steels and aluminium alloys. It was found that within the range of parameters investigated both of these methods can be recommended for the determination of the R-curve; however, since at small amounts of crack growth the DC potential drop method gave more consistent results it is therefore considered to be superior. The initation values J(0) of J determined by fractography were compared with J(Ic) as obtained by current practice. It was found that J(Ic) is poorly related to initation or to specific amount of crack growth. A modification of the J(Ic) procedure is proposed. Two contacting arrangements of the DC potential drop method were checked for initation detection: one indicates initation by a potential minimum (related to a J value J(min)), the other by the intersection of the R-curve with the blunting line (related to a J value J(int)). (orig.) [de

  16. DIAGNOSTIC CLASSIFICATION OF MENTAL HEALTH AND DEVELOPMENTAL DISORDERS OF INFANCY AND EARLY CHILDHOOD DC:0-5: SELECTIVE REVIEWS FROM A NEW NOSOLOGY FOR EARLY CHILDHOOD PSYCHOPATHOLOGY.

    Zeanah, Charles H; Carter, Alice S; Cohen, Julie; Egger, Helen; Gleason, Mary Margaret; Keren, Miri; Lieberman, Alicia; Mulrooney, Kathleen; Oser, Cindy

    2016-09-01

    The Diagnostic Classification of Mental Health and Developmental Disorders of Infancy and Early Childhood: Revised Edition (DC:0-5; ZERO TO THREE) is scheduled to be published in 2016. The articles in this section are selective reviews that have been undertaken as part of the process of refining and updating the nosology. They provide the rationales for new disorders, for disorders that had not been included previously in the Diagnostic Classification of Mental Health and Developmental Disorders of Infancy and Early Childhood: Revised Edition (DC:0-3R; ZERO TO THREE, 2005), and for changes in how certain types of disorders are conceptualized. © 2016 Michigan Association for Infant Mental Health.

  17. High voltage dc cables

    Bjustrom, B

    1965-12-01

    How stress distribution in dc cables varies with temperature and stress level, influence of polarity reversals and space charges, and different types of overvoltage to which dc cable may be subjected are discussed. Design problems, especially as related to corrosion protection and to mechanical stress caused by wire armoring during manufacturing and laying, accessories and work done on test methods, and the possibility of designing 400 to 600 kV dc cables for transmitting 2000 to 4000 MW are described.

  18. Effect of D.C. testing water tree deteriorated cable and a preliminary evaluation of V.L.F. as alternate

    Eager, G.S. Jr.; Fryszczyn, B.; Katz, C.; ElBadaly, H.A.; Jean, A.R.

    1992-01-01

    This paper reports that according to the experience of some power utilities, the application of industry recommended high voltage d.c. field tests on 5-35 kV extruded dielectric cables, containing water trees, sometimes causes further deterioration of the insulation. Tests conducted on laboratory aged 15 kV ethylene propylene rubber (EP) and 15 and 28 kV crosslinked polyethylene (XLPE) insulated cables indicate that d.c. proof tests in accordance with AEIC specifications an IEEE test guides without flashover do not appear to cause further deterioration. Depending on the degree of cable aging and the level of test voltage, when flashovers take place, damage may be inflicted to XLPE cables. No damage was observed on aged EP cable, at the same test levels. Because of the aforementioned power utility experience, some users have requested an alternate field proof test. Tests conducted on new XLPE and EP cables indicate that damage to the insulation structure can be detected using VLF (0.1 Hz) voltage at approximately one-third the d.c. voltage level. Field tests conducted on severely tree deteriorated 15 kV polyethylene (PE) cable using AEIC recommended d.c. voltage level of about five times operating voltage level caused cable failure; VLF voltage levels up to two times operating voltage did not. VLF voltage appears to be a suitable alternate to d.c. voltage for field proof testing

  19. Description of the PMAD DC test bed architecture and integration sequence

    Beach, R. F.; Trash, L.; Fong, D.; Bolerjack, B.

    1991-01-01

    NASA-LEWIS is responsible for the development, fabrication, and assembly of the electric power system (EPS) for the Space Station Freedom (SSF). The SSF power system is radically different from previous spacecraft power systems in both the size and complexity of the system. Unlike past spacecraft power systems, the SSF EPS will grow and be maintained on orbit and must be flexible to meet challenging user power needs. The SSF power system is also unique in comparison with terrestrial power systems because it is dominated by power electronic converters which regulate and control the power. A description is provided of the Power Management and Distribution DC Testbed which was assembled to support the design and early evaluation of the SSF EPS. A description of the integration process used in the assembly sequence is also given along with a description of the support facility.

  20. Design and Performance Test of Axial Halbach Brushless DC Motor with Power Density 1.5 Kw/Kg

    Kevin Dwi Prasetio

    2017-01-01

    Full Text Available Progress of technology on electric vehicle component sector is one reason the emergence of electric vehicles at the moment. Starting from battery which has a great current density up to the automatic control systems on electric vehicles. But there are still some shortcomings of this electric vehicle components, one of which is the low value of power density of existing electric motor in the market today.On vehicles such as electric cars when Race Car Contest, energy saving problems about power density of the driving motor is very vital. This is because the total weight of the vehicle has a huge influence on the vehicle efficiency is against it. The issue is one of the reasons of the research task. In this final task is done making the design, simulation, and architecture of the Axial Halbach Brushless DC Motor. Use of system configuration on the halbach magnet to avoid the use of iron as a material cantilever rotor. By changing the material of the cantilever rotor with lighter materials such as aluminum or even carbon fibre, the value of power density electric motors can be increased. Then using the litz wire on coil stator to reduce loss-power loss due to the barriers on the coil. Coreless stator on the system and to avoid the phenomenon of cogging at the time due to low rpm style attraction magnet with iron in the core material. While the creation process begins by determining the specifications of the Axial Halbach Brushless DC motors. Then go into the design phase of the mechanical and electrical design. Who then conducted simulations to help determine other parameters such as air gap, slot turn, and magnetic orientation. The process of making a component of stator and rotor after the simulation is completed. After all the components of the rotor and stator on assembly, mounting the hall sensor is carried out to the right to position obtained by reading the signals. After the motor can spin with good motor performance, testing can be done

  1. Nursing intellectual capital theory: testing selected propositions.

    Covell, Christine L; Sidani, Souraya

    2013-11-01

    To test the selected propositions of the middle-range theory of nursing intellectual capital. The nursing intellectual capital theory conceptualizes nursing knowledge's influence on patient and organizational outcomes. The theory proposes nursing human capital, nurses' knowledge, skills and experience, is related to the quality of patient care and nurse recruitment and retention of an inpatient care unit. Two factors in the work environment, nurse staffing and employer support for nurse continuing professional development, are proposed to influence nursing human capital's association with patient and organizational outcomes. A cross-sectional survey design. The study took place in 2008 in six Canadian acute care hospitals. Financial, human resource and risk data were collected from hospital departments and unit managers. Clearly specified empirical indicators quantified the study variables. The propositions of the theory were tested with data from 91 inpatient care units using structural equation modelling. The propositions associated with the nursing human capital concept were supported. The propositions associated with the employer support for nurse continuing professional development concept were not. The proposition that nurse staffing's influences on patient outcomes was mediated by the nursing human capital of an inpatient unit, was partially supported. Some of the theory's propositions were empirically validated. Additional theoretical work is needed to refine the operationalization and measurement of some of the theory's concepts. Further research with larger samples of data from different geographical settings and types of hospitals is required to determine if the theory can withstand empirical scrutiny. © 2013 Blackwell Publishing Ltd.

  2. 40 CFR 205.171-3 - Test motorcycle sample selection.

    2010-07-01

    ... 40 Protection of Environment 24 2010-07-01 2010-07-01 false Test motorcycle sample selection. 205... ABATEMENT PROGRAMS TRANSPORTATION EQUIPMENT NOISE EMISSION CONTROLS Motorcycle Exhaust Systems § 205.171-3 Test motorcycle sample selection. A test motorcycle to be used for selective enforcement audit testing...

  3. Multi Bus DC-DC Converter in Electric Hybrid Vehicles

    Krithika, V.; Subramaniam, C.; Sridharan, R.; Geetha, A.

    2018-04-01

    This paper is cotncerned with the design, simulation and fabrication of the prototype of a Multi bus DC- DC converter operating from 42V DC and delivering 14V DC and 260V DC. As a result, three DC buses are interconnected through a single power electronic circuitry. Such a requirement is energized in the development of a hybrid electric automobile which uses the technology of fuel cell. This is implemented by using a Bidirectional DC-DC converter configuration which is ideally suitable for multiple outputs with mutual electrical isolation. For the sake of reduced size and cost of step-up transformer, selection of a high frequency switching cycle at 10 KHz was done.

  4. Accelerated reliability testing of highly aligned single-walled carbon nanotube networks subjected to DC electrical stressing.

    Strus, Mark C; Chiaramonti, Ann N; Kim, Young Lae; Jung, Yung Joon; Keller, Robert R

    2011-07-01

    We investigate the electrical reliability of nanoscale lines of highly aligned, networked, metallic/semiconducting single-walled carbon nanotubes (SWCNTs) fabricated through a template-based fluidic assembly process. We find that these SWCNT networks can withstand DC current densities larger than 10 MA cm(-2) for several hours and, in some cases, several days. We develop test methods that show that the degradation rate, failure predictability and total device lifetime can be linked to the initial resistance. Scanning electron and transmission electron microscopy suggest that fabrication variability plays a critical role in the rate of degradation, and we offer an empirical method of quickly determining the long-term performance of a network. We find that well-fabricated lines subject to constant electrical stress show a linear accumulation of damage reminiscent of electromigration in metallic interconnects, and we explore the underlying physical mechanisms that could cause such behavior.

  5. Improvement of a high current DC power supply system for testing the large scaled superconducting cables and magnets

    Yamada, Shuichi; Chikaraishi, Hirotaka; Tanahashi, Shugo

    1993-11-01

    A dc 75 kA power supply system was constructed to test the superconducting (SC) R and D cables and magnets for the Large Helical Device. It consists of three 25 kA unit banks. A unit bank has two double-star-rectifier connections with the inter-phase reactors. A digital feedback control method is applied to the automatic current regulation (ACR) in each unit bank. For shortening the dead time of the feedback process, a new algorithm of a digital phase controller for the ACR is investigated. A Bode diagram of the feedback process is directly measured. It is confirmed that the dead time of the feedback process is reduced to one sixth, and that the feedback gain of PID compensation is improved by a factor of two from the original method. (author)

  6. Novel Field test design and initial result for AC and DC characterization for PV-panels

    Thorsteinsson, Sune; Riedel, Nicholas; Santamaria Lancia, Adrian Alejo

    This work describes the design and initial test results of a field test for PV modules, where the PV modules the majority of the time operates to produce power at their maximum power point. Sequentially the individual modules are switched into a measurement circuitry for IV curves and impedance s...

  7. Early Oscillation Detection for DC/DC Converter Fault Diagnosis

    Wang, Bright L.

    2011-01-01

    The electrical power system of a spacecraft plays a very critical role for space mission success. Such a modern power system may contain numerous hybrid DC/DC converters both inside the power system electronics (PSE) units and onboard most of the flight electronics modules. One of the faulty conditions for DC/DC converter that poses serious threats to mission safety is the random occurrence of oscillation related to inherent instability characteristics of the DC/DC converters and design deficiency of the power systems. To ensure the highest reliability of the power system, oscillations in any form shall be promptly detected during part level testing, system integration tests, flight health monitoring, and on-board fault diagnosis. The popular gain/phase margin analysis method is capable of predicting stability levels of DC/DC converters, but it is limited only to verification of designs and to part-level testing on some of the models. This method has to inject noise signals into the control loop circuitry as required, thus, interrupts the DC/DC converter's normal operation and increases risks of degrading and damaging the flight unit. A novel technique to detect oscillations at early stage for flight hybrid DC/DC converters was developed.

  8. Full range ZVS DC-DC converter

    Upadhyay, Rinki; Badapanda, M.K.; Hannurkar, P.R.

    2011-01-01

    A 500 V, 24 Amp DC-DC converter with digital signal processor (DSP) based control and protection has been designed, fabricated and tested. Its power circuit consists of IGBT based single phase inverter bridge, ferrite transformer and diode rectifier. All IGBTs in the inverter bridge are operated in zero voltage switching (ZVS) mode to minimize switching losses thereby increasing the efficiency of the converter significantly. The efficiency of this converter is measured to be greater than 97% at full load. In a conventional full bridge inverter, typically ZVS is achieved under full load condition while at light load ZVS is lost. An auxiliary LC circuit has been intentionally incorporated in this converter to achieve ZVS even at light loaded conditions. Detailed simulation of the converter circuit is carried out and crucial waveforms have been presented in this paper. Microchip make dsPIC30F2020 DSP is employed to provide phase shifted PWMs to IGBTs in the inverter bridge. All the crucial parameters are also monitored by this DSP and in case of any unfavorable conditions, the converter is tripped off. Suitable experiments were carried out in this DC-DC converter under different loaded conditions and a close match between the simulated and experimental results were obtained. Such DC-DC converters can be connected in series or parallel for the development of solid state modular power supplies for various applications. (author)

  9. Determination of efficiencies, loss mechanisms, and performance degradation factors in chopper controlled dc vehical motors. Section 1: Test program results and recommendations

    Hamilton, H. B.; Strangas, E.

    1980-01-01

    The conventional series motor model is discussed as well as procedures for obtaining, by test, the parameters necessary for calculating performance and losses. The calculated results for operation from ripple free DC are compared with observed test results, indicating approximately 5% or less error. Experimental data indicating the influence of brush shift and chopper frequency are also presented. Both factors have a significant effect on the speed and torque relationships. The losses and loss mechanisms present in a DC series motor are examined and an attempt is made to evaluate the added losses due to harmonic currents and fluxes. Findings with respect to these losses is summarized.

  10. Forward selection two sample binomial test

    Wong, Kam-Fai; Wong, Weng-Kee; Lin, Miao-Shan

    2016-01-01

    Fisher’s exact test (FET) is a conditional method that is frequently used to analyze data in a 2 × 2 table for small samples. This test is conservative and attempts have been made to modify the test to make it less conservative. For example, Crans and Shuster (2008) proposed adding more points in the rejection region to make the test more powerful. We provide another way to modify the test to make it less conservative by using two independent binomial distributions as the reference distribution for the test statistic. We compare our new test with several methods and show that our test has advantages over existing methods in terms of control of the type 1 and type 2 errors. We reanalyze results from an oncology trial using our proposed method and our software which is freely available to the reader. PMID:27335577

  11. Change-based test selection : An empirical evaluation

    Soetens, Quinten; Demeyer, Serge; Zaidman, A.E.; Perez, Javier

    2015-01-01

    Regression test selection (i.e., selecting a subset of a given regression test suite) is a problem that has been studied intensely over the last decade. However, with the increasing popularity of developer tests as the driver of the test process, more fine-grained solutions that work well within the

  12. Item selection and ability estimation adaptive testing

    Pashley, Peter J.; van der Linden, Wim J.; van der Linden, Willem J.; Glas, Cornelis A.W.; Glas, Cees A.W.

    2010-01-01

    The last century saw a tremendous progression in the refinement and use of standardized linear tests. The first administered College Board exam occurred in 1901 and the first Scholastic Assessment Test (SAT) was given in 1926. Since then, progressively more sophisticated standardized linear tests

  13. Milliwatt dc/dc Inverter

    Mclyman, C. W.

    1983-01-01

    Compact dc/dc inverter uses single integrated-circuit package containing six inverter gates that generate and amplify 100-kHz square-wave switching signal. Square-wave switching inverts 10-volt local power to isolated voltage at another desired level. Relatively high operating frequency reduces size of filter capacitors required, resulting in small package unit.

  14. Validity of selected cardiovascular field-based test among Malaysian ...

    Based on emerge obese problem among Malaysian, this research is formulated to validate published tests among healthy female adult. Selected test namely; 20 meter multi-stage shuttle run, 2.4km run test, 1 mile walk test and Harvard Step test were correlated with laboratory test (Bruce protocol) to find the criterion validity ...

  15. Testing Selective Transmission with Low Power Listening

    Hansen, Morten Tranberg; Arroyo-Valles, Rocio; Cid-Sueiro, Jesus

    2010-01-01

    Selective transmission policies allow nodes in a sensor network to autonomously decide between transmitting or discarding packets depending on the importance of the information content and the energetic cost of communications. The potential benefits of these policies depend on the capability...

  16. Selection of tests for outlier detection

    Bossers, H.C.M.; Hurink, Johann L.; Smit, Gerardus Johannes Maria

    Integrated circuits are tested thoroughly in order to meet the high demands on quality. As an additional step, outlier detection is used to detect potential unreliable chips such that quality can be improved further. However, it is often unclear to which tests outlier detection should be applied and

  17. Atmel Microcontroller Based Soft Switched PWM ZVS Full Bridge DC to DC Converter

    DEEPAK KUMAR NAYAK

    2010-12-01

    Full Text Available This paper deals with the simulation and implementation of soft switched PWM ZVS full bridge DC to DC converter. The 48V DC is efficiently reduced to 12V DC using a DC to DC converter. This converter has advantages like reduced switching losses, stresses and EMI. Input DC is converted into high frequency AC and it is stepped down to 12V level. Later it is rectified using a full wave rectifier. Laboratory model of microcontroller based DC to DC converter is fabricated and tested. The experimental results are compared with the simulation results.

  18. AUTOMATED MEASURING COMPLEX FOR ACCEPTANCE TESTING OF DC AND UNDULATED-CURRENT TRACTION MOTORS

    A. Yu. Drubetskyi

    2016-12-01

    Full Text Available Purpose. In the paper it is necessary: 1 to familiarize the reader with the modern classification of measurement and diagnostics, familiarize with problems of automating the measurement of basic parameters during program execution of qualification tests of traction motors; 2 to make recommendations to improve the measurement ac-curacy, reduce labor intensity of work for carrying out measurements, and reduce the requirements for the qualification of the staff; 3 to provide practical implementation of measurement system, built on the basis of the practical recommendations contained in the article. Methodology. The work presents the classification of measurement and diagnostic tools. The author considered a list of equipment that can be used in measurement systems, as well as third-party options for measuring complex and measuring complex using stand management system. Their functional schemes were proposed. The author compared the advantages and disadvantages of these schemes to make recommendations on areas of their optimal use. Findings. Having analyzed the functional scheme of measuring systems, it was found that the use of the control system microcontroller as a measuring complex is expedient if the measurements have largely a test process control function. The use of a third-party measuring complex is more appropriate in cases when it is required: to eliminate dependence on the stand management system, to provide high mobility and reduce the requirements for the qualification of the staff. Originality. The work presents a brief over-view of the measurement means. The author developed the functional schemes of measuring systems using stand management system and third-party measuring complex, proposed the criteria for evaluating their optimal use. Practical value. Based on the proposed functional diagram, the measuring system on National Instruments hard-ware and software basis was set up. The sensors by LEM Company were used as primary

  19. A 2-megawatt load for testing high voltage DC power supplies

    Horan, D.; Kustom, R.; Ferguson, M.; Primdahl, K.

    1993-01-01

    A high power water-cooled resistive load, capable of dissipating 2 Megawatts at 95 kilovolts is being designed and built. The load utilizes wirewound resistor elements suspended inside insulating tubing contained within a pressure vessel which is supplied a continuous flow of deionized water for coolant. A sub-system of the load is composed of non-inductive resistor elements in an oil tank. Power tests conducted on various resistor types indicate that dissipation levels as high as 22 times the rated dissipation in air can be achieved when the resistors are placed in a turbulent water flow of at least 15 gallons per minute. Using this data, the load was designed using 100 resistor elements in a series arrangement. A single-wall 316 stainless steel pressure vessel with flanged torispherical heads is built to contain the resistor assembly and deionized water. The resistors are suspended within G-11 tubing which span the cylindrical length of the vessel. These tubes are supported by G-10 baffles which also increase convection from the tubes by promoting turbulence within the surrounding water

  20. Merits of usability testing for PACS selection

    Jorritsma, Wiard; Cnossen, Fokie; van Ooijen, Peter M. A.

    Objectives: To compare the usability of different Picture Archiving and Communication System (PACS) workstations, determine whether a usability test has added value with respect to the traditional way of comparing PACSs based on functional requirements, and to evaluate the appropriateness of a

  1. Coefficient alpha and interculture test selection.

    Thurber, Steven; Kishi, Yasuhiro

    2014-04-01

    The internal consistency reliability of a measure can be a focal point in an evaluation of the potential adequacy of an instrument for adaptation to another cultural setting. Cronbach's alpha (α) coefficient is often used as the statistical index for such a determination. However, alpha presumes a tau-equivalent test and may constitute an inaccurate population estimate for multidimensional tests. These notions are expanded and examined with a Japanese version of a questionnaire on nursing attitudes toward suicidal patients, originally constructed in Sweden using the English language. The English measure was reported to have acceptable internal consistency (α) albeit the dimensionality of the questionnaire was not addressed. The Japanese scale was found to lack tau-equivalence. An alternative to alpha, "composite reliability," was computed and found to be below acceptable standards in magnitude and precision. Implications for research application of the Japanese instrument are discussed. © The Author(s) 2012.

  2. Attitudes, perceptions and behaviours towards HIV testing among African-American and East African immigrant women in Washington, DC: implications for targeted HIV testing promotion and communication strategies.

    De Jesus, Maria; Carrete, Claudia; Maine, Cathleen; Nalls, Patricia

    2015-12-01

    The objective of the study was to examine and compare the HIV testing attitudes, perceptions and behaviours between African-American and East African immigrant women in the Washington, DC metropolitan area. Adopting an inductive, qualitative methodological approach, we conducted a total of 40 in-depth, semistructured interviews between October 2012 and March 2013. Qualitative thematic analysis was used to analyse the data. Overall, African-American women held more favourable views towards HIV testing than East African immigrant women. Very few East African immigrant women sought HIV testing intentionally. The majority of East African participants were tested inadvertently, while others tested for immigration-related or employment-related purposes. There were many barriers that impede women from seeking an HIV test including negative assumptions (eg, "Getting an HIV test implies that I am HIV positive"), negative emotions (eg, "Fear of being diagnosed with HIV and what this will mean for me") and potential negative reactions from partner or others (eg, "Getting an HIV test can signal distrust, disrespect, or infidelity"). There were nuances in how each group articulated some of these barriers and East African women expressed unique concerns that originated from experiences in their home countries. The study shed light into the complexity of factors that constrain women from presenting themselves voluntarily for an HIV test and highlighted the nuances between African-American and East African perceptions. Implications of findings for effective targeted HIV screening promotion and communication strategies among these groups of women are discussed. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/

  3. Selection of DC voltage magnitude using Fibonacci series for new hybrid asymmetrical multilevel inverter with minimum PIV

    M.R. Banaei

    2014-09-01

    Full Text Available Multilevel inverters are suggested to obtain high quality output voltage. In this paper, a new hybrid configuration is proposed, obtained by cascading one four switches H-bridge cell with a family of multilevel inverters. In addition, by the use of specific sequence for value of DC sources named Fibonacci series, asymmetrical topology of proposed inverter is introduced. Main advantages are that proposed inverter has least Peak Inverse Voltage (PIV than other conventional multilevel converters in both symmetric and asymmetric modes. Also, this topology doubles the number of output levels using only one cascaded four switches H-bridge cell. The PCI-1716 DAQ using PC has been used to generate switching pulses in experimental results. For presenting valid performance of proposed configuration, simulation results carried out by MATLAB/SIMULINK software and the validity of the proposed multilevel inverter is verified by experimental results.

  4. Selected isokinetic tests in knee injury prevention

    W Pilis

    2010-03-01

    Full Text Available Ensuing from isokinetic measurements, the conventional Hcon/Qcon ratio of muscle balance is used as an index for comparing proper relations between the values of strength of knee flexors and extensor muscle. Its abnormal values might indicate pathology of the musculotendinous complex. The aim of the study was to present the possibility of using this ratio as one of the objective identifiers enabling the assessment of knee injury risk in sports. All participants (n=48 were divided into 3 groups: group A (n=16, healthy competitors, group B (n=16, athletes with minor injuries, group C (n=16, competitors with serious injuries, depending on the degree of knee injury. All subjects performed an isokinetic test for knee extensors and flexors at angular velocities of 60°/s and 120°/s. Average peak torque (APT value of knee flexors and extensors, and the value of Hcon/Qcon ratio was analyzed. Both values were calculated in relation to body mass (Nm/kg. Bilateral comparison of isokinetic test parameters confirmed the decrease of quadriceps muscle strength values for the injured extremity in groups B and C. Statistically significant difference was noted for Hcon/Qcon ratio between group A and C, as well as B and C. Hence, the value of conventional Hcon/Qcon ratio can be used for the prevention of sports related injuries.

  5. HYBRID DATA APPROACH FOR SELECTING EFFECTIVE TEST CASES DURING THE REGRESSION TESTING

    Mohan, M.; Shrimali, Tarun

    2017-01-01

    In the software industry, software testing becomes more important in the entire software development life cycle. Software testing is one of the fundamental components of software quality assurances. Software Testing Life Cycle (STLC)is a process involved in testing the complete software, which includes Regression Testing, Unit Testing, Smoke Testing, Integration Testing, Interface Testing, System Testing & etc. In the STLC of Regression testing, test case selection is one of the most importan...

  6. On and off controlled resonant dc-dc power converter

    2015-01-01

    The present invention relates to a resonant DC-DC power converter comprising an input side circuit comprising a positive and a negative input terminal for receipt of an input voltage or current and an output side circuit comprising positive and negative output terminals for supply of a converter...... output voltage and connection to a converter load. The resonant DC-DC power converter further comprises a rectification circuit connected between an output of a resonant network and the output side circuit. The resonant network is configured for alternatingly being charged from the input voltage...... or current and discharged through the rectification circuit by a first controllable switch arrangement in accordance with a first switch control signal. A second controllable switch arrangement of the resonant DC-DC power converter is configured to select a first impedance characteristic of the resonant...

  7. Procedures for Selecting Items for Computerized Adaptive Tests.

    Kingsbury, G. Gage; Zara, Anthony R.

    1989-01-01

    Several classical approaches and alternative approaches to item selection for computerized adaptive testing (CAT) are reviewed and compared. The study also describes procedures for constrained CAT that may be added to classical item selection approaches to allow them to be used for applied testing. (TJH)

  8. Testing Non-Stationarity in Selected Macroeconomic Series from ...

    The study tested stationarity in a selected set of macroeconomic variables (some constructed) from Sudan over the period 1969 to 1998. Augmented Dickey Fuller tests were employed to test for presence of unit roots. The study found that unit roots existed in most variables, namely, private investment, public investment, real ...

  9. A DC-DC Conversion Powering Scheme for the CMS Phase-1 Pixel Upgrade

    Feld, Lutz Werner; Marcel Friedrichs; Richard Hensch; Karpinski, Waclaw; Klein, Katja; Sammet, Jan Domenik; Wlochal, Michael

    2012-01-01

    The powering scheme of the CMS pixel detector will be described, and the performance of prototype DC-DC buck converters will be presented, including power efficiency, system tests with DC-DC converters and pixel modules, thermal management, reliability at low temperature, and studies of potential frequency locking betwe...

  10. Testing, Selection, and Implementation of Random Number Generators

    Collins, Joseph C

    2008-01-01

    An exhaustive evaluation of state-of-the-art random number generators with several well-known suites of tests provides the basis for selection of suitable random number generators for use in stochastic simulations...

  11. A Unidirectional DC-DC Autotransformer for DC Grid Application

    Meng Zhou

    2018-03-01

    Full Text Available Conventional unidirectional DC-DC converters for DC grid application employ DC-AC-DC two-stage conversion technology and suffer from high converter cost and power loss. To solve these issues, a unidirectional step-up DC-DC autotransformer (UUDAT and a unidirectional step-down DC-DC autotransformer (DUDAT are studied. The UUDAT and DUDAT are composed of a series connection of diode bridges and voltage source converters. Topologies of UUDAT and DUDAT are detailed. The harmonic and un-controllability issues are discussed. Control and possible application scenarios for UUDAT and DUDAT are depicted. DC fault isolation mechanism and the methods of dimensioning the voltage and power ratings of the components in UUDAT and DUDAT are studied. Extensive simulations on power system level and experiments on a UUDAT and DUDAT prototype verified their technical feasibility.

  12. Computerized adaptive testing item selection in computerized adaptive learning systems

    Eggen, Theodorus Johannes Hendrikus Maria; Eggen, T.J.H.M.; Veldkamp, B.P.

    2012-01-01

    Item selection methods traditionally developed for computerized adaptive testing (CAT) are explored for their usefulness in item-based computerized adaptive learning (CAL) systems. While in CAT Fisher information-based selection is optimal, for recovering learning populations in CAL systems item

  13. 40 CFR 205.57-2 - Test vehicle sample selection.

    2010-07-01

    ... pursuant to a test request in accordance with this subpart will be selected in the manner specified in the... then using a table of random numbers to select the number of vehicles as specified in paragraph (c) of... with the desig-nated AQL are contained in Appendix I, -Table II. (c) The appropriate batch sample size...

  14. Investigating gaze-controlled input in a cognitive selection test

    Gayraud, Katja; Hasse, Catrin; Eißfeldt, Hinnerk; Pannasch, Sebastian

    2017-01-01

    In the field of aviation, there is a growing interest in developing more natural forms of interaction between operators and systems to enhance safety and efficiency. These efforts also include eye gaze as an input channel for human-machine interaction. The present study investigates the application of gaze-controlled input in a cognitive selection test called Eye Movement Conflict Detection Test. The test enables eye movements to be studied as an indicator for psychological test performance a...

  15. Design and Testing of a Low Cost PID Controller Combined with Inverse Derivative Control Action and Its Application in Voltage Control Systems of DC Generator

    Subrata CHATTOPADHYAY

    2008-01-01

    Full Text Available A single PID controller in a process control loop may suffer from high frequency oscillations without offset or low frequency oscillation with offset. An inverse derivative control action can eliminate both of these errors. In the present paper, a low cost operational amplifier based PID controller with inverse derivative control action has been described. Its transfer function has been derived and is found to be identical with the form already derived by other workers. It has been tested with a process plant analogue and implemented in the voltage control system of a DC generator. Its transfer function along with its characteristics in a process plant analogue and the load characteristics of DC generator with and without this controller have been determined experimentally and reported in this paper.

  16. Optimal Selective Harmonic Mitigation Technique on Variable DC Link Cascaded H-Bridge Converter to Meet Power Quality Standards

    Najjar, Mohammad; Moeini, Amirhossein; Dowlatabadi, Mohammadkazem Bakhshizadeh

    2016-01-01

    In this paper, the power quality standards such as IEC 61000-3-6, IEC 61000-2-12, EN 50160, and CIGRE WG 36-05 are fulfilled for single- and three-phase medium voltage applications by using Selective Harmonic Mitigation-PWM (SHM-PWM) in a Cascaded H-Bridge (CHB) converter. Furthermore, the ER G5/...

  17. Implementation of Computer Assisted Test Selection System in Local Governments

    Abdul Azis Basri

    2016-05-01

    Full Text Available As an evaluative way of selection of civil servant system in all government areas, Computer Assisted Test selection system was started to apply in 2013. In phase of implementation for first time in all areas in 2014, this system selection had trouble in several areas, such as registration procedure and passing grade. The main objective of this essay was to describe implementation of new selection system for civil servants in the local governments and to seek level of effectiveness of this selection system. This essay used combination of study literature and field survey which data collection was made by interviews, observations, and documentations from various sources, and to analyze the collected data, this essay used reduction, display data and verification for made the conclusion. The result of this essay showed, despite there a few parts that be problem of this system such as in the registration phase but almost all phases of implementation of CAT selection system in local government areas can be said was working clearly likes in preparation, implementation and result processing phase. And also this system was fulfilled two of three criterias of effectiveness for selection system, they were accuracy and trusty. Therefore, this selection system can be said as an effective way to select new civil servant. As suggestion, local governments have to make prime preparation in all phases of test and make a good feedback as evaluation mechanism and together with central government to seek, fix and improve infrastructures as supporting tool and competency of local residents.

  18. Step-Up DC-DC converters

    Forouzesh, Mojtaba; Siwakoti, Yam P.; Gorji, Saman A.

    2017-01-01

    on the general law and framework of the development of next-generation step-up dc-dc converters, this paper aims to comprehensively review and classify various step-up dc-dc converters based on their characteristics and voltage-boosting techniques. In addition, the advantages and disadvantages of these voltage...

  19. Analysis on working pressure selection of ACME integral test facility

    Chen Lian; Chang Huajian; Li Yuquan; Ye Zishen; Qin Benke

    2011-01-01

    An integral effects test facility, advanced core cooling mechanism experiment facility (ACME) was designed to verify the performance of the passive safety system and validate its safety analysis codes of a pressurized water reactor power plant. Three test facilities for AP1000 design were introduced and review was given. The problems resulted from the different working pressures of its test facilities were analyzed. Then a detailed description was presented on the working pressure selection of ACME facility as well as its characteristics. And the approach of establishing desired testing initial condition was discussed. The selected 9.3 MPa working pressure covered almost all important passive safety system enables the ACME to simulate the LOCAs with the same pressure and property similitude as the prototype. It's expected that the ACME design would be an advanced core cooling integral test facility design. (authors)

  20. Model Selection in Continuous Test Norming With GAMLSS.

    Voncken, Lieke; Albers, Casper J; Timmerman, Marieke E

    2017-06-01

    To compute norms from reference group test scores, continuous norming is preferred over traditional norming. A suitable continuous norming approach for continuous data is the use of the Box-Cox Power Exponential model, which is found in the generalized additive models for location, scale, and shape. Applying the Box-Cox Power Exponential model for test norming requires model selection, but it is unknown how well this can be done with an automatic selection procedure. In a simulation study, we compared the performance of two stepwise model selection procedures combined with four model-fit criteria (Akaike information criterion, Bayesian information criterion, generalized Akaike information criterion (3), cross-validation), varying data complexity, sampling design, and sample size in a fully crossed design. The new procedure combined with one of the generalized Akaike information criterion was the most efficient model selection procedure (i.e., required the smallest sample size). The advocated model selection procedure is illustrated with norming data of an intelligence test.

  1. DC Home Appliances for DC Distribution System

    MUHAMMAD KAMRAN

    2017-10-01

    Full Text Available This paper strengthens the idea of DC distribution system for DC microgrid consisting of a building of 50 apartments. Since the war of currents AC system has been dominant because of the paucity of research in the protection of the DC system. Now with the advance research in power electronics material and components, generation of electricity is inherently DC as by solar PV, fuel cell and thermoelectric generator that eliminates the rectification process. Transformers are replaced by the power electronics buck-boost converters. DC circuit breakers have solved the protection problems for both DC transmission and distribution system. In this paper 308V DC microgrid is proposed and home appliances (DC internal are modified to operate on 48V DC from DC distribution line. Instead of using universal and induction motors in rotary appliances, BLDC (Brushless DC motors are proposed that are highly efficient with minimum electro-mechanical and no commutation losses. Proposed DC system reduces the power conversion stages, hence diminishes the associated power losses and standby losses that boost the overall system efficiency. So in view of all this a conventional AC system can be replaced by a DC system that has many advantages by cost as well as by performance

  2. The Free and Cued Selective Reminding Test: Pictures vs. Words

    Pettit, Annabel

    2013-01-01

    The present study tested a group of young (18-25) and old (>60) healthy adults to examine whether a pictorial superiority effect influences performance in the free and cued selective reminding test (FCSRT). 81 participants were recruited and performed the ACE-R, TOPF and FCSRT. Stimulus items for the FCSRT consisted of either 16 line drawings (in the picture form) or 16 written words (in the word form). The design was completely-between subjects and the form of test was fully counterbalanced...

  3. Thyristors for dc transmission

    1966-05-06

    As a first stage towards determining the feasibility of applying thyristors to hvdc converter terminals, the Westinghouse Electric Corporation has built a converter laboratory capable of testing thyristors under conditions similar to those which would have to be met in a 200 kV dc system. The equipment has been designed to test a 5 kV 600 A group of thyrisotrs, elevated 200 kV above earth. This rating has been chosen so that there would be a sufficient number of thyristors in series to enable the gating and voltage division characteristics to be investigated and at the same time the group could be operated at a potential equivalent to a complete 200 kV dc bridge.

  4. Plan for metal barrier selection and testing for NNWSI

    Halsey, W.G.; McCright, R.D.

    1987-12-01

    The Department of Energy's Nevada Nuclear Waste Storage Investigations (NNWSI) Project is evaluating a site at Yucca Mountain in Nevada as a geological repository for the storage of high-level nuclear waste. The Nuclear Waste Management Projects (NWMP) at Lawrence Livermore National Laboratory (LLNL) has the responsibility for design, testing, and performance analysis of the NNWSI waste packages. One portion of this work is the selection and testing of the material for container construction. The anticipated container design is for this material to be a corrosion resistant metal called the metal barrier. This document is the publication version of the Scientific Investigation Plan (SIP) for the Metal Barrier Selection and Testing Task. The SIP serves as a formal planning document for the investigation and is used to assign quality assurance levels to the activities of the task. This document is an informal version for information distribution and has the sections on ''Schedule and Milestones'' and the ''Quality Assurance Level Assignment Sheets'' removed

  5. Step-Up DC-DC converters

    Forouzesh, Mojtaba; Siwakoti, Yam P.; Gorji, Saman A.

    2017-01-01

    on the general law and framework of the development of next-generation step-up dc-dc converters, this paper aims to comprehensively review and classify various step-up dc-dc converters based on their characteristics and voltage-boosting techniques. In addition, the advantages and disadvantages of these voltage......DC-DC converters with voltage boost capability are widely used in a large number of power conversion applications, from fraction-of-volt to tens of thousands of volts at power levels from milliwatts to megawatts. The literature has reported on various voltage-boosting techniques, in which......-boosting techniques and associated converters are discussed in detail. Finally, broad applications of dc-dc converters are presented and summarized with comparative study of different voltage-boosting techniques....

  6. Data Quality Objectives For Selecting Waste Samples To Test The Fluid Bed Steam Reformer Test

    Banning, D.L.

    2010-01-01

    This document describes the data quality objectives to select archived samples located at the 222-S Laboratory for Fluid Bed Steam Reformer testing. The type, quantity and quality of the data required to select the samples for Fluid Bed Steam Reformer testing are discussed. In order to maximize the efficiency and minimize the time to treat Hanford tank waste in the Waste Treatment and Immobilization Plant, additional treatment processes may be required. One of the potential treatment processes is the fluid bed steam reformer (FBSR). A determination of the adequacy of the FBSR process to treat Hanford tank waste is required. The initial step in determining the adequacy of the FBSR process is to select archived waste samples from the 222-S Laboratory that will be used to test the FBSR process. Analyses of the selected samples will be required to confirm the samples meet the testing criteria.

  7. DC electric springs with DC/DC converters

    Wang, Qingsong; Cheng, Ming; Jiang, Yunlei

    2016-01-01

    The concept of DC electric spring (DCES) was recently proposed to solve the stability issue caused by integrating intermittent renewable energy sources (RESs) to DC microgrids. In this paper, a new topology of DCES is proposed based on DC/DC converters. The proposed DCES consists of a bi-directio......The concept of DC electric spring (DCES) was recently proposed to solve the stability issue caused by integrating intermittent renewable energy sources (RESs) to DC microgrids. In this paper, a new topology of DCES is proposed based on DC/DC converters. The proposed DCES consists of a bi...... and/or constant discharging for batteries is adopted and four operating modes are analyzed as charging-positive, charging-negative, discharging-positive and discharging-negative modes. An additional mechanism for fast charging or fast discharging is also designed to secure normal operation...... of batteries. With the proposed DCES, the power fluctuations due to intermittent RESs can be passed to non-critical loads (NCLs) and batteries while power on critical loads (CLs) is kept stable. This is possibly the first attempt to design a DCES with only DC/DC converters. The performances of the proposed...

  8. Analysis and testing of a double armature brushless dc linear motor with NdFeB permanent magnets

    Filho, A.F.F.

    1998-01-01

    The use of high-energy product NdFeB permanent magnets benefits the design and features of a double armature brushless dc linear motor. As the linear motor is also slotless, its 5 mm airgap requires a source of high flux to overcome the reluctance and produce an adequate amount of force. The linear motor employs a topology that makes use of five permanent magnets to provide excitation flux. The permanent magnets are arranged in such a way that maximises the force the linear motor can deliver. The actuator produces a force up to 86.2 N at an armature current of 4.5 A. However, the topology makes the actuator prone to saturation. It affects the operation point of the permanent magnets, reduces the airgap flux density and the force, and increases flux leakage. To avoid saturation, a flux compensation scheme was conceived. The results are presented and assessed by means of finite element simulation and by experimental results that presented a good agreement. (orig.)

  9. Cellular evidence for selfish spermatogonial selection in aged human testes.

    Maher, G J; Goriely, A; Wilkie, A O M

    2014-05-01

    Owing to a recent trend for delayed paternity, the genomic integrity of spermatozoa of older men has become a focus of increased interest. Older fathers are at higher risk for their children to be born with several monogenic conditions collectively termed paternal age effect (PAE) disorders, which include achondroplasia, Apert syndrome and Costello syndrome. These disorders are caused by specific mutations originating almost exclusively from the male germline, in genes encoding components of the tyrosine kinase receptor/RAS/MAPK signalling pathway. These particular mutations, occurring randomly during mitotic divisions of spermatogonial stem cells (SSCs), are predicted to confer a selective/growth advantage on the mutant SSC. This selective advantage leads to a clonal expansion of the mutant cells over time, which generates mutant spermatozoa at levels significantly above the background mutation rate. This phenomenon, termed selfish spermatogonial selection, is likely to occur in all men. In rare cases, probably because of additional mutational events, selfish spermatogonial selection may lead to spermatocytic seminoma. The studies that initially predicted the clonal nature of selfish spermatogonial selection were based on DNA analysis, rather than the visualization of mutant clones in intact testes. In a recent study that aimed to identify these clones directly, we stained serial sections of fixed testes for expression of melanoma antigen family A4 (MAGEA4), a marker of spermatogonia. A subset of seminiferous tubules with an appearance and distribution compatible with the predicted mutant clones were identified. In these tubules, termed 'immunopositive tubules', there is an increased density of spermatogonia positive for markers related to selfish selection (FGFR3) and SSC self-renewal (phosphorylated AKT). Here we detail the properties of the immunopositive tubules and how they relate to the predicted mutant clones, as well as discussing the utility of

  10. Fatigue Testing of Dental Bridges on Selected Examples

    Urban Dariusz

    2017-03-01

    Full Text Available The paper presents example tests of the functional quality of selected designs of dental bridges. These were: porcelain bridges on a metal base (cobalt based alloy, porcelain bridges on a zirconia base (zirconia ceramic – Zirkon Zahn, and full zirconia bridges (Zirkon Zahn. For the purpose of the study, durability of bridges in cyclic fatigue testing was adopted as a measure of their quality. The tests were carried out on a Zwick Roell Z010 universal testing machine. They consisted in cyclic loading and unloading of dental bridges mounted on gypsum models at a loading force of F= 400 [N] and a frequency of load of f= 1 [Hz]. Each bridge was subjected to a cycle of 7200 loads. The results show that there are no significant differences in the functional quality of the bridges.

  11. Modified Anderson-Darling tests with selective power improvement

    Cabaña Nigro, Alejandra

    2001-01-01

    Transformed empirical processes (TEPs) have been used by the authors in a previous paper to construct consistent and selectively efficient goodness-of-fit tests of the Kolmogorov-Smirnov type. A straightforward application of the same ideas to the construction of tests of the Cramér-von-Mises type with the same properties leads to cumbersome computations. This short note of the incovenients encountered, and introduces a new family of quadratic statistics of the Cramér-von Mises type, in order...

  12. Design and operational experience and testing of 50 kW/120 kHz oscillator for 3 MeV, 30 kW DC accelerator

    Srivastava, S.K.; Bakhtsingh, R.I.; Saroj, P.C.

    2011-01-01

    A 3 MeV, 30 kW dc industrial electron beam Accelerator is being developed at EBC, Kharghar, Navi Mumbai. The 3 MV dc is generated by parallel coupled voltage multiplier operating at 120 kHz. This requires an input voltage of 150 kV-0-150 kV at 120 kHz. This is achieved by 50 kW/120 kHz power oscillator in conjunction with a tuned air-core step-up transformer. Input primary voltage of 6 kV-0-6 kV at 120 kHz is generated by an oscillator using BW1121J2 water cooled triodes in push-pull Colpitts configuration. The tank circuit for the oscillator is formed by the secondary winding inductance of the step-up transformer and capacitance formed by RF feeder electrodes of the voltage multiplier column. Grid feedback for the oscillator is derived by arranging a set of electrodes in the feeder assembly in a capacitive divider configuration. The oscillator is operated in class-C mode with grid leak bias for better efficiency which also has the advantages of self-adjustment with varying load conditions. High power test has been conducted in a simulated test set-up on dummy load up to 30kW. Subsequently, the power oscillator has been tested with HV multiplier at 1MeV level satisfactorily. This paper describes the design, test results and operational experiences of the oscillator. (author)

  13. Males that drop a sexually selected weapon grow larger testes.

    Joseph, Paul N; Emberts, Zachary; Sasson, Daniel A; Miller, Christine W

    2018-01-01

    Costly sexually selected weapons are predicted to trade off with postcopulatory traits, such as testes. Although weapons can be important for achieving access to females, individuals of some species can permanently drop (i.e. autotomize) their weapons, without regeneration, to escape danger. We capitalized on this natural behavior to experimentally address whether the loss of a sexually selected weapon leads to increased testes investment in the leaf-footed cactus bug, Narnia femorata Stål (Hemiptera: Coreidae). In a second experiment, we measured offspring production for males that lost a weapon during development. As predicted, males that dropped a hind limb during development grew significantly larger testes than the control treatments. Hind-limb autotomy did not result in the enlargement of other nearby traits. Our results are the first to experimentally demonstrate that males compensate for natural weapon loss by investing more in testes. In a second experiment we found that females paired with males that lost a hind limb had 40% lower egg hatching success than females paired with intact males, perhaps because of lower mating receptivity to males with a lost limb. Importantly, in those cases where viable offspring were produced, males missing a hind limb produced 42% more offspring than males with intact limbs. These results suggest that the loss of a hind-limb weapon can, in some cases, lead to greater fertilization success. © 2017 The Author(s). Evolution © 2017 The Society for the Study of Evolution.

  14. A resonant dc-dc power converter assembly

    2015-01-01

    The present invention relates to a resonant DC-DC power converter assembly comprising a first resonant DC-DC power converter and a second resonant DC-DC power converter having identical circuit topologies. A first inductor of the first resonant DC-DC power converter and a second inductor of the s......The present invention relates to a resonant DC-DC power converter assembly comprising a first resonant DC-DC power converter and a second resonant DC-DC power converter having identical circuit topologies. A first inductor of the first resonant DC-DC power converter and a second inductor...... of the second resonant DC-DC power converter are configured for magnetically coupling the first and second resonant DC-DC power converters to each other to forcing substantially 180 degrees phase shift, or forcing substantially 0 degree phase shift, between corresponding resonant voltage waveforms of the first...

  15. DC Cable for Railway

    Tomita, Masaru

    The development of a superconducting cable for railways has commenced, assuming that a DC transmission cable will be used for electric trains. The cable has been fabricated based on the results of current testing of a superconducting wire, and various evaluation tests have been performed to determine the characteristics of the cable. A superconducting transmission cable having zero electrical resistance and suitable for railway use is expected to enhance regeneration efficiency, reduce power losses, achieve load leveling and integration of sub-stations, and reduce rail potential.

  16. Development of a DC-DC conversion powering scheme for the CMS Phase-1 pixel upgrade

    Feld, Lutz Werner; Karpinski, Waclaw; Klein, Katja; Lipinski, Martin; Preuten, Marius; Max Rauch; Rittich, David Michael; Sammet, Jan Domenik; Wlochal, Michael

    2014-01-01

    A novel powering scheme based on the DC-DC conversion technique will be exploited to power the CMS Phase-1 pixel detector. DC-DC buck converters for the CMS pixel project have been developed, based on the AMIS5 ASIC designed by CERN. The powering system of the Phase-1 pixel detector is described and the performance of the converter prototypes is detailed, including power efficiency, stability of the output voltage, shielding, and thermal management. Results from a test of the magnetic field tolerance of the DC-DC converters are reported. System tests with pixel modules using many components of the future pixel barrel system are summarized. Finally first impressions from a pre-series of 200 DC-DC converters are presented.

  17. On selection of optimal stochastic model for accelerated life testing

    Volf, P.; Timková, J.

    2014-01-01

    This paper deals with the problem of proper lifetime model selection in the context of statistical reliability analysis. Namely, we consider regression models describing the dependence of failure intensities on a covariate, for instance, a stressor. Testing the model fit is standardly based on the so-called martingale residuals. Their analysis has already been studied by many authors. Nevertheless, the Bayes approach to the problem, in spite of its advantages, is just developing. We shall present the Bayes procedure of estimation in several semi-parametric regression models of failure intensity. Then, our main concern is the Bayes construction of residual processes and goodness-of-fit tests based on them. The method is illustrated with both artificial and real-data examples. - Highlights: • Statistical survival and reliability analysis and Bayes approach. • Bayes semi-parametric regression modeling in Cox's and AFT models. • Bayes version of martingale residuals and goodness-of-fit test

  18. Materials Compatibility Testing in RSRM ODC: Free Cleaner Selection

    Keen, Jill M.; Sagers, Neil W.; McCool, Alex (Technical Monitor)

    2001-01-01

    Government regulations have mandated production phase-outs of a number of solvents, including 1,1,1-trichloroethane, an ozone-depleting chemical (ODC). This solvent was used extensively in the production of the Reusable Solid Rocket Motors (RSRMs) for the Space Shuttle. Many tests have been performed to identify replacement cleaners. One major area of concern in the selection of a new cleaner has been compatibility. Some specific areas considered included cleaner compatibility with non-metallic surfaces, painted surfaces, support materials such as gloves and wipers as well as corrosive properties of the cleaners on the alloys used on these motors. The intent of this paper is to summarize the test logic, methodology, and results acquired from testing the many cleaner and material combinations.

  19. Differences in gender performance on competitive physics selection tests

    Wilson, Kate; Low, David; Verdon, Matthew; Verdon, Alix

    2016-12-01

    [This paper is part of the Focused Collection on Gender in Physics.] We have investigated gender differences in performance over the past eight years on the Australian Science Olympiad Exam (ASOE) for physics, which is taken by nearly 1000 high school students each year. The ASOE, run by Australian Science Innovations (ASI), is the initial stage of the process of selection of teams to represent Australia at the Asian and International Physics Olympiads. Students taking the exam are generally in their penultimate year of school and selected by teachers as being high performing in physics. Together with the overall differences in facility, we have investigated how the content and presentation of multiple-choice questions (MCQs) affects the particular answers selected by male and female students. Differences in the patterns of responses by male and female students indicate that males and females might be modeling situations in different ways. Some strong patterns were found in the gender gaps when the questions were categorized in five broad dimensions: content, process required, difficulty, presentation, and context. Almost all questions saw male students performing better, although gender differences were relatively small for questions with a more abstract context. Male students performed significantly better on most questions with a concrete context, although notable exceptions were found, including two such questions where female students performed better. Other categories that showed consistently large gaps favoring male students include questions with projectile motion and other two-dimensional motion or forces content, and processes involving interpreting diagrams. Our results have important implications, suggesting that we should be able to reduce the gender gaps in performance on MCQ tests by changing the way information is presented and setting questions in contexts that are less likely to favor males over females. This is important as MCQ tests are

  20. Differences in gender performance on competitive physics selection tests

    Kate Wilson

    2016-08-01

    Full Text Available [This paper is part of the Focused Collection on Gender in Physics.] We have investigated gender differences in performance over the past eight years on the Australian Science Olympiad Exam (ASOE for physics, which is taken by nearly 1000 high school students each year. The ASOE, run by Australian Science Innovations (ASI, is the initial stage of the process of selection of teams to represent Australia at the Asian and International Physics Olympiads. Students taking the exam are generally in their penultimate year of school and selected by teachers as being high performing in physics. Together with the overall differences in facility, we have investigated how the content and presentation of multiple-choice questions (MCQs affects the particular answers selected by male and female students. Differences in the patterns of responses by male and female students indicate that males and females might be modeling situations in different ways. Some strong patterns were found in the gender gaps when the questions were categorized in five broad dimensions: content, process required, difficulty, presentation, and context. Almost all questions saw male students performing better, although gender differences were relatively small for questions with a more abstract context. Male students performed significantly better on most questions with a concrete context, although notable exceptions were found, including two such questions where female students performed better. Other categories that showed consistently large gaps favoring male students include questions with projectile motion and other two-dimensional motion or forces content, and processes involving interpreting diagrams. Our results have important implications, suggesting that we should be able to reduce the gender gaps in performance on MCQ tests by changing the way information is presented and setting questions in contexts that are less likely to favor males over females. This is important as MCQ

  1. Development of a green mode DC/DC converter available to portable nuclear instrument

    Gao Feiyan; Wu Longxiong; Tan Wei; Tang Yaogeng

    2010-01-01

    A green mode DC/DC converter was developed which suitable to the portable nuclear instrument which is powered by battery and is sometime at stand-by mode. Some updated control approaches such as pseudo-resonant type power supply control and synchronous rectification were adopted to makethe DC/DC converter operate with low power consumption and high efficiency. The test results the battery can be prolonged with this converter. (authors)

  2. Tribological Testing, Analysis and Characterization of D.C. Magnetron Sputtered Ti-Nb-N Thin Film Coatings on Stainless Steel

    Joshi, Prathmesh

    To enhance the surface properties of stainless steel, the substrate was coated with a 1μm thick coating of Ti-Nb-N by reactive DC magnetron sputtering at different N2 flow rates, substrate biasing and Nb-Ti ratio. The characterization of the coated samples was performed by the following techniques: hardness by Knoop micro-hardness tester, phase analysis by X-ray Diffraction (XRD), compositional analysis by Energy Dispersive X-ray Spectroscopy (EDS) and adhesion by scratch test. The tribology testing was performed on linearly reciprocating ball-on-plate wear testing machine and wear depth and wear volume were evaluated by white light interferometer. The micro-hardness test yielded appreciable enhancement in the surface hardness with the highest value being 1450 HK. Presence of three prominent phases namely NbN, Nb2N3 and TiN resulted from the XRD analysis. EDS analysis revealed the presence of Ti, Nb and Nitrogen. Adhesion was evaluated on the basis of critical loads for cohesive (Lc1) and adhesive (Lc2) failures with values varying between 7-12 N and 16-25 N respectively, during scratch test for coatings on SS substrates.

  3. Tc-99 Adsorption on Selected Activated Carbons - Batch Testing Results

    Mattigod, Shas V.; Wellman, Dawn M.; Golovich, Elizabeth C.; Cordova, Elsa A.; Smith, Ronald M.

    2010-12-01

    CH2M HILL Plateau Remediation Company (CHPRC) is currently developing a 200-West Area groundwater pump-and-treat system as the remedial action selected under the Comprehensive Environmental Response, Compensation, and Liability Act Record of Decision for Operable Unit (OU) 200-ZP-1. This report documents the results of treatability tests Pacific Northwest National Laboratory researchers conducted to quantify the ability of selected activated carbon products (or carbons) to adsorb technetium-99 (Tc-99) from 200-West Area groundwater. The Tc-99 adsorption performance of seven activated carbons (J177601 Calgon Fitrasorb 400, J177606 Siemens AC1230AWC, J177609 Carbon Resources CR-1240-AW, J177611 General Carbon GC20X50, J177612 Norit GAC830, J177613 Norit GAC830, and J177617 Nucon LW1230) were evaluated using water from well 299-W19-36. Four of the best performing carbons (J177606 Siemens AC1230AWC, J177609 Carbon Resources CR-1240-AW, J177611 General Carbon GC20X50, and J177613 Norit GAC830) were selected for batch isotherm testing. The batch isotherm tests on four of the selected carbons indicated that under lower nitrate concentration conditions (382 mg/L), Kd values ranged from 6,000 to 20,000 mL/g. In comparison. Under higher nitrate (750 mg/L) conditions, there was a measureable decrease in Tc-99 adsorption with Kd values ranging from 3,000 to 7,000 mL/g. The adsorption data fit both the Langmuir and the Freundlich equations. Supplemental tests were conducted using the two carbons that demonstrated the highest adsorption capacity to resolve the issue of the best fit isotherm. These tests indicated that Langmuir isotherms provided the best fit for Tc-99 adsorption under low nitrate concentration conditions. At the design basis concentration of Tc 0.865 µg/L(14,700 pCi/L), the predicted Kd values from using Langmuir isotherm constants were 5,980 mL/g and 6,870 mL/g for for the two carbons. These Kd values did not meet the target Kd value of 9,000 mL/g. Tests

  4. Patterns of HIV/AIDS, STI, Substance Abuse and Hepatitis Risk among Selected Samples of Latino and African-American Youth in Washington, DC

    Edberg, Mark C.; Collins, Elizabeth; Harris, Meredith; McLendon, Hedda; Santucci, Patricia

    2009-01-01

    In order to address evolving risk factors among youth in Washington, DC (District of Columbia), with respect to HIV/AIDS, sexually transmitted infections (STIs), substance abuse, and hepatitis, a targeted, community-needs assessment was conducted through a partnership between the Department of Prevention and Community Health at George Washington…

  5. DC KIDS COUNT e-Databook Indicators

    DC Action for Children, 2012

    2012-01-01

    This report presents indicators that are included in DC Action for Children's 2012 KIDS COUNT e-databook, their definitions and sources and the rationale for their selection. The indicators for DC KIDS COUNT represent a mix of traditional KIDS COUNT indicators of child well-being, such as the number of children living in poverty, and indicators of…

  6. Borehole DC-6 hydrostratigraphic chart

    Gephart, R.E.

    1981-09-01

    This hydrostratigraphic chart for Borehole DC-6 identifies the basic stratigraphy and preliminary hydrologic test results. This borehole was cored for obtaining stratigraphic data and only that portion within the Grande Ronde formation remains open for hydrologic testing. The upper two formations were cased and cemented off

  7. Dual wound dc brush motor gearhead

    Henson, Barrie W.

    1986-01-01

    The design requirements, the design, development tests and problems, the qualification and life test and the findings of the strip examination of a dual wound DC brushed motor gearhead are described. It is the only space qualified dual wound dc brushed motor gearhead in Europe.

  8. A resonant dc-dc power converter assembly

    Madsen, Mickey Pierre

    2015-01-01

    The present invention relates to a resonant DC-DC power converter assembly comprising a first resonant DC-DC power converter and a second resonant DC-DC power converter having identical circuit topologies. A first inductor of the first resonant DC-DC power converter and a second inductor of the second resonant DC-DC power converter are configured for magnetically coupling the first and second resonant DC-DC power converters to each other to forcing substantially 180 degrees phase shift, or fo...

  9. Practical Design Guidelines of qZSI Based Step-Up DC/DC Converter

    Zakis, Janis; Vinnikov, Dmitri; Roasto, Indrek; Jalakas, Tanel

    2010-01-01

    This paper presents some design guidelines for a new voltage fed step-up DC/DC isolated converter. The most significant advantage of proposed converter is voltage buck-boost operation on single stage. The most promising application for proposed converter is in the field of distributed power generation e.g. fuel cells or photovoltaic. The most sensitive issues - such as power losses caused by high currents in the input side of converter and high transient overvoltages across the inverter bridge caused by stray inductances were discussed and solved. The proposals and recommendations to overcome these issues are given in the paper. The Selection and design guidelines of converter elements are proposed and explained. The prototype of proposed converter was built and experimentally tested. Some results are presented and evaluated.

  10. Controlling DC permeability in cast steels

    Sumner, Aaran; Gerada, Chris; Brown, Neil; Clare, Adam

    2017-01-01

    Annealing (at multiple cooling rates) and quenching (with tempering) was performed on specimens of cast steel of varying composition. The aim was to devise a method for selecting the steel with the highest permeability, from any given range of steels, and then increasing the permeability by heat treatment. Metallographic samples were imaged using optical microscopy to show the effect of the applied heat treatments on the microstructure. Commonly cast steels can have DC permeability altered by the careful selection of a heat treatment. Increases of up to 381% were achieved by annealing using a cooling rate of 6.0 °C/min. Annealing was found to cause the carbon present in the steel to migrate from grain boundaries and from within ferrite crystals into adjacent pearlite crystals. The migration of the carbon resulted in less carbon at grain boundaries and within ferrite crystals reducing the number of pinning sites between magnetic domains. This gives rise to a higher permeability. Quenching then tempering was found to cause the formation of small ferrite crystals with the carbon content of the steel predominately held in the martensitic crystal structures. The results show that with any given range of steel compositions the highest baseline DC permeability will be found with the steel that has the highest iron content and the lowest carbon content. For the samples tested in this paper a cooling rate of 4.5 °C/min resulted in the relative permeability of the sample with the highest baseline permeability, AS4, increasing from 783 to 1479 at 0.5 T. This paper shows how heat treatments commonly applied to hypoeutectoid cast steels, to improve their mechanical performance, can be used to also enhance electromagnetic properties of these alloys. The use of cast steels allows the creation of DC components for electrical machines not possible by the widely used method of stacking of electrical grade sheet steels. - Highlights: • A range of structural steels had their

  11. Controlling DC permeability in cast steels

    Sumner, Aaran, E-mail: aaran.sumner@nottingham.ac.uk [University of Nottingham, Nottingham University Park Campus, Nottingham NG7 2RD, England (United Kingdom); Gerada, Chris, E-mail: chris.gerada@nottingham.ac.uk [Electrical Machines, University of Nottingham, Tower Building, Nottingham NG7 2RD, England (United Kingdom); Brown, Neil, E-mail: neil.brown@cummins.com [Advanced Electrical Machines Research and Technology at Cummins Power Generation, Peterborough PE2 6FZ, England (United Kingdom); Clare, Adam, E-mail: adam.clare@nottingham.ac.uk [Advanced Manufacturing, University of Nottingham, University Park Campus, Nottingham NG7 2RD, England (United Kingdom)

    2017-05-01

    Annealing (at multiple cooling rates) and quenching (with tempering) was performed on specimens of cast steel of varying composition. The aim was to devise a method for selecting the steel with the highest permeability, from any given range of steels, and then increasing the permeability by heat treatment. Metallographic samples were imaged using optical microscopy to show the effect of the applied heat treatments on the microstructure. Commonly cast steels can have DC permeability altered by the careful selection of a heat treatment. Increases of up to 381% were achieved by annealing using a cooling rate of 6.0 °C/min. Annealing was found to cause the carbon present in the steel to migrate from grain boundaries and from within ferrite crystals into adjacent pearlite crystals. The migration of the carbon resulted in less carbon at grain boundaries and within ferrite crystals reducing the number of pinning sites between magnetic domains. This gives rise to a higher permeability. Quenching then tempering was found to cause the formation of small ferrite crystals with the carbon content of the steel predominately held in the martensitic crystal structures. The results show that with any given range of steel compositions the highest baseline DC permeability will be found with the steel that has the highest iron content and the lowest carbon content. For the samples tested in this paper a cooling rate of 4.5 °C/min resulted in the relative permeability of the sample with the highest baseline permeability, AS4, increasing from 783 to 1479 at 0.5 T. This paper shows how heat treatments commonly applied to hypoeutectoid cast steels, to improve their mechanical performance, can be used to also enhance electromagnetic properties of these alloys. The use of cast steels allows the creation of DC components for electrical machines not possible by the widely used method of stacking of electrical grade sheet steels. - Highlights: • A range of structural steels had their

  12. Selection of the DC-60 cyclotron as the basic facility for the Inter-disciplinary research complex in the L.N. Gumilev Eurasian State University. Chapter 2

    2003-01-01

    In the Chapter 2 the DC-60 specialized accelerator project of the Inter-disciplinary research complex in the L.N. Gumilev Eurasian State University is described. The DC-60 cyclotron is intended for applied studies which can be accomplished on both the ion beams of the electron cyclotron resonance source with voltage up to 25 kV and the accelerated ions from carbon to xenon. The cyclotron is design on the base of compact magnet with weight about 74 tonnes, and it mean magnetic field is 1.6 T, section angle - 50 Deg. Design of the Inter-disciplinary research complex building in the L.N. Gumilev Eurasian State University is described as well. Technical performances of the building and their parameters are given

  13. THE METHOD OF SELECTION OF THE SETPOINT HIGH SPEED FEEDER SWITCH OF 3,3KV DC WITH MICROPROCESSOR-BASED PROTECTION SYSTEMS

    P. Ye. Mykhalichenko

    2009-10-01

    Full Text Available In the article a new procedure of choice of minimum current jump for action of fast-acting switches of 3.3 kV DC traction substations intended for the use in the microprocessor protection system of feeders is described. This procedure is more perfect than existing one on the current increment and uses the results of mathematical simulation of the traction electric supply system.

  14. The Dornier 328 Acoustic Test Cell (ATC) for interior noise tests and selected test results

    Hackstein, H. Josef; Borchers, Ingo U.; Renger, Klaus; Vogt, Konrad

    1992-01-01

    To perform acoustic studies for achieving low noise levels for the Dornier 328, an acoustic test cell (ATC) of the Dornier 328 has been built. The ATC consists of a fuselage section, a realistic fuselage suspension system, and three exterior noise simulation rings. A complex digital 60 channel computer/amplifier noise generation system as well as multichannel digital data acquisition and evaluation system have been used. The noise control tests started with vibration measurements for supporting acoustic data interpretation. In addition, experiments have been carried out on dynamic vibration absorbers, the most important passive noise reduction measure for low frequency propeller noise. The design and arrangement of the current ATC are presented. Furthermore, exterior noise simulation as well as data acquisition are explained. The most promising results show noise reduction due to synchrophasing and dynamic vibration absorbers.

  15. HOW TO SELECT APPROPRIATE STATISTICAL TEST IN SCIENTIFIC ARTICLES

    Vladimir TRAJKOVSKI

    2016-09-01

    Full Text Available Statistics is mathematical science dealing with the collection, analysis, interpretation, and presentation of masses of numerical data in order to draw relevant conclusions. Statistics is a form of mathematical analysis that uses quantified models, representations and synopses for a given set of experimental data or real-life studies. The students and young researchers in biomedical sciences and in special education and rehabilitation often declare that they have chosen to enroll that study program because they have lack of knowledge or interest in mathematics. This is a sad statement, but there is much truth in it. The aim of this editorial is to help young researchers to select statistics or statistical techniques and statistical software appropriate for the purposes and conditions of a particular analysis. The most important statistical tests are reviewed in the article. Knowing how to choose right statistical test is an important asset and decision in the research data processing and in the writing of scientific papers. Young researchers and authors should know how to choose and how to use statistical methods. The competent researcher will need knowledge in statistical procedures. That might include an introductory statistics course, and it most certainly includes using a good statistics textbook. For this purpose, there is need to return of Statistics mandatory subject in the curriculum of the Institute of Special Education and Rehabilitation at Faculty of Philosophy in Skopje. Young researchers have a need of additional courses in statistics. They need to train themselves to use statistical software on appropriate way.

  16. Power Quality in DC Power Distribution Systems and Microgrids

    Stephen Whaite

    2015-05-01

    Full Text Available This review paper discusses power quality considerations for direct current (DC electric power distribution systems, particularly DC microgrids. First, four selected sample DC architectures are discussed to provide motivation for the consideration of power quality in DC systems. Second, a brief overview of power quality challenges in conventional alternating current (AC distribution systems is given to establish the field of power quality. Finally, a survey of literature addressing power quality issues in DC systems is presented, and necessary power quality considerations in DC distribution system design and operation are discussed.

  17. Optimisation or satiation, testing diet selection rules in goats

    Jansen, D.A.W.A.M.; Langevelde, van F.; Boer, de W.F.; Kirkman, K.P.

    2007-01-01

    Several hypotheses have been formulated to explain diet selection by herbivores, focusing on the maximization of nutrient intake, the minimization of plant secondary compounds, or the satiety hypothesis. This research aimed at studying diet selection revealing which chemical characteristics of

  18. DC/DC converters for integration of double-layer condensers in onboard power supply; DC/DC-Wandler zur Einbindung von Doppelschichtkondensatoren in das Fahrzeugenergiebordnetz

    Polenov, Dieter

    2010-01-15

    The paper discusses DC/DC converters for integration of double layer condensers into the onboard power system. First, requirements on DC/DC converters are listed and compared on the basis of three exemplary applications. A DC/DC converter concept is developed for decoupling transient high-power loads like electric steering systems. Three different topologies are compared using a specially developed method in order to find the best solution for the given application. In order to establish adequate criteria for selecting the switching frequency and inductivities of storage throttles, the influence of the trottle power change on the switching characteristics of the MOSFETs and on certain ranges of EMP interference emissions is investigated. As methods of optimising the operation of the synchronous rectifiers, parallel connection of Schottky diodes and synchronous rectifiers as well as the variation of the shut-off dead times of synchronous rectifiers were investigated. Further, a concept for converter control was developed in consideration of the intended application and topology. Finally, selected aspects for implementation of the DC/DC converter concept are presented as well as the results of experimental investigations.

  19. Selected hydraulic test analysis techniques for constant-rate discharge tests

    Spane, F.A. Jr.

    1993-03-01

    The constant-rate discharge test is the principal field method used in hydrogeologic investigations for characterizing the hydraulic properties of aquifers. To implement this test, the aquifer is stressed by withdrawing ground water from a well, by using a downhole pump. Discharge during the withdrawal period is regulated and maintained at a constant rate. Water-level response within the well is monitored during the active pumping phase (i.e., drawdown) and during the subsequent recovery phase following termination of pumping. The analysis of drawdown and recovery response within the stress well (and any monitored, nearby observation wells) provides a means for estimating the hydraulic properties of the tested aquifer, as well as discerning formational and nonformational flow conditions (e.g., wellbore storage, wellbore damage, presence of boundaries, etc.). Standard analytical methods that are used for constant-rate pumping tests include both log-log type-curve matching and semi-log straight-line methods. This report presents a current ''state of the art'' review of selected transient analysis procedures for constant-rate discharge tests. Specific topics examined include: analytical methods for constant-rate discharge tests conducted within confined and unconfined aquifers; effects of various nonideal formation factors (e.g., anisotropy, hydrologic boundaries) and well construction conditions (e.g., partial penetration, wellbore storage) on constant-rate test response; and the use of pressure derivatives in diagnostic analysis for the identification of specific formation, well construction, and boundary conditions

  20. Social desirability bias in personality testing: Implications for astronaut selection

    Sandal, Gro M.; Musson, Dave; Helmreich, Robert. L.; Gravdal, Lene

    2005-07-01

    The assessment of personality is recognized by space agencies as an approach to identify candidates likely to perform optimally during spaceflights. In the use of personality scales for selection, the impact of social desirability (SD) has been cited as a concern. Study 1 addressed the impact of SD on responses to the Personality Characteristic Inventory (PCI) and NEO-FFI. This was achieved by contrasting scores from active astronauts (N=65) with scores of successful astronaut applicants (N=63), and between pilots applicants (N=1271) and pilot research subjects (N=120). Secondly, personality scores were correlated with scores on the Marlow Crown Social Desirability Scale among applicants to managerial positions (N=120). The results indicated that SD inflated scores on PCI scales assessing negative interpersonal characteristics, and impacted on four of five scales in NEO-FFI. Still, the effect sizes were small or moderate. Study 2 addressed performance implications of SD during an assessment of males applying to work as rescue personnel operations in the North Sea (N=22). The results showed that SD correlated negatively with cognitive test performance, and positively with discrepancy in performance ratings between self and two observers. In conclusion, caution is needed in interpreting personality scores in applicant populations. SD may be a negative predictor for performance under stress.

  1. Development of an HIV Testing Dashboard to Complement the HIV Care Continuum Among MSM, PWID, and Heterosexuals in Washington, DC, 2007-2015.

    Patrick, Rudy; Greenberg, Alan; Magnus, Manya; Opoku, Jenevieve; Kharfen, Michael; Kuo, Irene

    2017-07-01

    We developed an HIV testing dashboard to complement the HIV care continuum in selected high-risk populations. Using National HIV Behavioral Surveillance (NHBS) data, we examined trends in HIV testing and care for men who have sex with men (MSM), persons who inject drugs (PWID), and heterosexuals at elevated risk (HET). Between 2007 and 2015, 4792 participants ≥18 years old completed a behavioral survey and were offered HIV testing. For the testing dashboard, proportions ever tested, tested in the past year, testing HIV-positive, and newly testing positive were calculated. An abbreviated care continuum for self-reported positive (SRP) persons included ever engagement in care, past year care, and current antiretroviral (ARV) use. The testing dashboard and care continuum were calculated separately for each population. Chi-square test for trend was used to assess significant trends over time. Among MSM, lifetime HIV testing and prevalence significantly increased from 96% to 98% (P = 0.01) and 14%-20% (P = 0.02) over time; prevalence was highest among black MSM at all time points. HIV prevalence among female persons who inject drugs was significantly higher in 2015 vs. 2009 (27% and 13%; P dashboard can be used to complement the HIV care continuum to display improvements and disparities in HIV testing and care over time.

  2. Drilling history core hole DC-8

    1978-10-01

    Core hole DC-8 was completed in August, 1978 by Boyles Brothers Drilling Company, Spokane, Washington, under subcontract to Fenix and Scission, Inc. The hole was cored for the US Department of Energy and the Rockwell Hanford Operations' Basalt Waste Isolation Program. Fenix and Scisson, Inc. furnished the engineering, daily supervision of the core drilling activities, and geologic core logging for hole DC-8. Core hole DC-8 is located on the Hanford Site near the Wye Barricade and 50 feet northwest of rotary hole DC-7. The Hanford Site vation coordinates for DC-8 are North 14,955.94 feet and West 14,861.92 coordinates for DC-8 are North 14,955.94 feet and West 14,861.92 mean sea level. The purpose of core hole DC-8 was to core drill vertically through the basalt and interbed units for stratigraphic depth determination and core collection, and to provide a borehole for hydrologic testing and cross-hole seismic shear and pressure wave velocity studies with rotary hole DC-7. The total depth of core hole DC-8 was 4100.5 feet. Core recovery exceeded 97 percent of the total footage cored

  3. Drilling history core hole DC-8

    1978-10-01

    Core hole DC-8 was completed in August, 1978 by Boyles Brothers Drilling Company, Spokane, Washington, under subcontract to Fenix and Scission, Inc. The hole was cored for the US Department of Energy and the Rockwell Hanford Operations' Basalt Waste Isolation Program. Fenix and Scisson, Inc. furnished the engineering, daily supervision of the core drilling activities, and geologic core logging for hole DC-8. Core hole DC-8 is located on the Hanford Site near the Wye Barricade and 50 feet northwest of rotary hole DC-7. The Hanford Site vation coordinates for DC-8 are North 14,955.94 feet and West 14,861.92 coordinates for DC-8 are North 14,955.94 feet and West 14,861.92 mean sea level. The purpose of core hole DC-8 was to core drill vertically through the basalt and interbed units for stratigraphic depth determination and core collection, and to provide a borehole for hydrologic testing and cross-hole seismic shear and pressure wave velocity studies with rotary hole DC-7. The total depth of core hole DC-8 was 4100.5 feet. Core recovery exceeded 97 percent of the total footage cored.

  4. Attitudes, perceptions, and behaviors toward HIV testing among African American and East African immigrant women in Washington, D.C.: Implications for targeted HIV testing promotion and communication strategies

    De Jesus, Maria; Carrete, Claudia; Maine, Cathleen; Nalls, Patricia

    2015-01-01

    Objectives The objective of the study was to examine and compare the HIV testing attitudes, perceptions, and behaviors between African American and East African immigrant women in the Washington, D.C. Metropolitan area. Methods Adopting an inductive, qualitative methodological approach, we conducted a total of 40 in-depth, semi-structured interviews between October 2012 and March 2013. Qualitative thematic analysis was used to analyze the data. Results Overall, African American women held more favorable views toward HIV testing than East African immigrant women. Very few East African immigrant women sought HIV testing intentionally. The majority of East African participants were tested inadvertently, while others tested for immigration- or employment-related purposes. There were many barriers that impede women from seeking an HIV test including: negative assumptions (e.g., ‘Getting an HIV test implies that I am HIV positive’); negative emotions (e.g., ‘Fear of being diagnosed with HIV and what this will mean for me’); and potential negative reactions from partner or others (e.g., ‘Getting an HIV test can signal distrust, disrespect, or infidelity’). There were nuances in how each group articulated some of these barriers and East African women expressed unique concerns that originated from experiences in their home countries. Conclusions The study shed light into the complexity of factors that constrain women from presenting themselves voluntarily for an HIV test and highlighted the nuances between African American and East African perceptions. Implications of findings for effective targeted HIV screening promotion and communication strategies among these groups of women are discussed. PMID:25897146

  5. Wall and corner fire tests on selected wood products

    H. C. Tran; M. L. Janssens

    1991-01-01

    As part of a fire growth program to develop and validate a compartment fire model, several bench-scale and full-scale tests were conducted. This paper reports the full-scale wall and corner test results of step 2 of this study. A room fire test following the ASTM proposed standard specifications was used for these full-scale tests. In step 1, we investigated the...

  6. Comparison of coagulation activity tests in vitro for selected biomaterials

    van Oeveren, W; Haan, J; Lagerman, P; Schoen, T

    Testing of coagulation induced by external communicating medical devices is an International Standardisation Organization (ISO) requirement for products exposed to human blood. Four categories of tests are indicated by ISO 10993/4: a clotting test (partial thromboplastin time; PTT), thrombin

  7. Family of multiport bidirectional DC-DC converters

    Tao, H.; Kotsopoulos, A.; Duarte, J.L.; Hendrix, M.A.M.

    2006-01-01

    Multiport DC-DC converters are of potential interest in applications such as generation systems utilising multiple sustainable energy sources. A family of multiport bidirectional DC-DC converters derived from a general topology is presented. The topology shows a combination of DC-link and magnetic

  8. dc power system for deuteron accelerator

    Creek, K.O.; Liska, D.J.

    1981-01-01

    The Fusion Materials Irradiation Test (FMIT) Facility dc power system provides excitation current for all linac and High-Energy Beam Transport (HEBT) quadrupole and bending magnets, excitation for horizontal and vertical beam steering, and current-bypass shunts.

  9. Age-Related Differences in Goals: Testing Predictions from Selection, Optimization, and Compensation Theory and Socioemotional Selectivity Theory

    Penningroth, Suzanna L.; Scott, Walter D.

    2012-01-01

    Two prominent theories of lifespan development, socioemotional selectivity theory and selection, optimization, and compensation theory, make similar predictions for differences in the goal representations of younger and older adults. Our purpose was to test whether the goals of younger and older adults differed in ways predicted by these two…

  10. First Implementation of a Two-Stage DC-DC Conversion Powering Scheme for the CMS Phase-2 Outer Tracker

    Feld, Lutz Werner; Karpinski, Waclaw; Klein, Katja; Lipinski, Martin; Pauls, Alexander Josef; Preuten, Marius; Rauch, Max Philip; Wangelik, Frederik; Wlochal, Michael

    2017-01-01

    The 2S silicon strip modules for the CMS Phase-2 tracker upgrade will require two operating voltages. These will be provided via a two-step DC-DC conversion powering scheme, in which one DC-DC converter delivers 2.5\\,V while the second DC-DC converter receives 2.5\\,V at its input and converts it to 1.2\\,V. The DC-DC converters will be mounted on a flex PCB, the service hybrid, together with an opto-electrical converter module (VTRx+) and a serializer (LP-GBT). The service hybrid will be mounted directly on the 2S module. A prototype service hybrid has been developed and its performance has been evaluated, including radiative and conductive noise emissions, and efficiency. In addition system tests with a prototype module have been performed. In this report the service hybrid will be described and the test results will be summarized.

  11. Programmable dc motor controller

    Hopwood, J. E.

    1982-11-01

    A portable programmable dc motor controller, with features not available on commercial instruments was developed for controlling fixtures during welding processes. The controller can be used to drive any dc motor having tachometer feedback and motor requirements not exceeding 30 volts, 3 amperes. Among the controller's features are delayed start time, upslope time, speed, and downslope time.

  12. Racial Bias and Predictive Validity in Testing for Selection.

    1983-07-01

    the inequa - lity rR (P.C) *0 (2) must define test bias. This definition of test bias conforms to the requirements of the Civil Rights Act of 1964 as...of Educational Measurement, 1976, 13, 43-52. Einhorn, H. J., & Bass, A. R. Methodological considerations relevant to discrimination in employment ...34unbiased" selec- tion model: A question of utilities. Journal of Applied Psychology, 1975, 60, 345-351. Guion, R. M. Employment tests and discriminatory

  13. Tritium activities in selected wells on the Nevada Test Site

    Lyles, B.F.

    1993-05-01

    Literature and data were reviewed related to radionuclides in groundwater on and near the Nevada Test Site. No elevated tritium activities have been reported outside of the major testing regions of the Nevada Test Site. Three wells were identified as having water with above-background (>50 pCi/l) tritium activities: UE-15d Water Well; USGS Water Well A; and USGS Test Well B Ex. Although none of these wells have tritium activities greater than the Nevada State Drinking Water standard (20,000 pCi/l), their time-series tritium trends may be indicative to potential on-site radionuclide migration

  14. Multilevel DC link inverter

    Su, Gui-Jia

    2003-06-10

    A multilevel DC link inverter and method for improving torque response and current regulation in permanent magnet motors and switched reluctance motors having a low inductance includes a plurality of voltage controlled cells connected in series for applying a resulting dc voltage comprised of one or more incremental dc voltages. The cells are provided with switches for increasing the resulting applied dc voltage as speed and back EMF increase, while limiting the voltage that is applied to the commutation switches to perform PWM or dc voltage stepping functions, so as to limit current ripple in the stator windings below an acceptable level, typically 5%. Several embodiments are disclosed including inverters using IGBT's, inverters using thyristors. All of the inverters are operable in both motoring and regenerating modes.

  15. Differences in Gender Performance on Competitive Physics Selection Tests

    Wilson, Kate; Low, David; Verdon, Matthew; Verdon, Alix

    2016-01-01

    We have investigated gender differences in performance over the past eight years on the Australian Science Olympiad Exam (ASOE) for physics,which is taken by nearly 1000 high school students each year. The ASOE, run by Australian Science Innovations (ASI), is the initial stage of the process of selection of teams to represent Australia at the…

  16. Relevant test set using feature selection algorithm for early detection ...

    The objective of feature selection is to find the most relevant features for classification. Thus, the dimensionality of the information will be reduced and may improve classification's accuracy. This paper proposed a minimum set of relevant questions that can be used for early detection of dyslexia. In this research, we ...

  17. Sex Role Learning: A Test of the Selective Attention Hypothesis.

    Bryan, Janice Westlund; Luria, Zella

    This paper reports three studies designed to determine whether children show selective attention and/or differential memory to slide pictures of same-sex vs. opposite-sex models and activities. Attention was measured using a feedback EEG procedure, which measured the presence or absence of alpha rhythms in the subjects' brains during presentation…

  18. Study of the mechanisms of flux enhancement through hairless mouse skin by pulsed DC iontophoresis

    Pikal, M.J.; Shah, S.

    1991-01-01

    Enhanced iontophoretic transport using pulsed DC is usually explained by citing the observed decrease in skin resistance caused by an increase in AC pulse frequency at very small currents. Alternately, it has been suggested that the on-to-off nature of pulsed DC imparts an impact energy to the fluid, thereby increasing transport. This report provides a test of these mechanisms for enhanced delivery via pulsed iontophoresis. The DC resistance of hairless mouse skin during continuous and pulsed DC iontophoresis is measured as a function of time for selected pulse frequencies and duty cycles using current densities ranging from 0.1 to 1.0 mA/cm2. As a test of the impact energy mechanism, the iontophoretic transport of 14C-glucose measured with pulsed DC is compared with similar data obtained previously using continuous DC. It is suggested that pulsed current can yield lower resistance and enhanced drug delivery provided that (a) the steady-state current during the on phase of the pulse is very small and (b) the frequency is low enough to allow depolarization of the skin during the off phase of the pulse. The glucose transport results suggest that the impact energy concept does not apply to iontophoresis

  19. Effects of Selected Object Characteristics on Object Permanence Test Performance.

    Lingle, Kathleen M.; Lingle, John H.

    A study was conducted to investigate the degree to which both object familiarity and motivational factors influence infants' search behavior in an object permanence test. Infants' search behavior for an unfamiliar test object was compared with search behavior for (a) an experientially familiar object that each infant had played with daily for a…

  20. Early selection of Eucalyptus clones in retrospective nursery test ...

    Within the framework of the eucalyptus breeding programme in the Congo, two retrospective tests were conducted using mature clones in the field and young cuttings under nursery conditions with two hybrids: 13 clones of Eucalyptus tereticornis* Eucalyptus grandis for the test TC 82-1B and 17 clones of Eucalyptus ...

  1. Modelling, Simulation and Construction of a DC/DC Boost Power Converter: A School Experimental System

    Silva-Ortigoza, R.; Silva-Ortigoza, G.; Hernandez-Guzman, V. M.; Saldana-Gonzalez, G.; Marcelino-Aranda, M.; Marciano-Melchor, M.

    2012-01-01

    We introduce a dc/dc boost power converter as a didactic prototype intended to support courses on electric circuit analysis experimentally. The corresponding mathematical model is obtained, the converter is designed and an experimental setup is described, constructed and tested. Simplicity of construction as well as low cost of components renders…

  2. Modelling, simulation and construction of a dc/dc boost power converter: a school experimental system

    Silva-Ortigoza, R; Marciano-Melchor, M; Silva-Ortigoza, G; Hernández-Guzmán, V M; Saldaña-González, G; Marcelino-Aranda, M

    2012-01-01

    We introduce a dc/dc boost power converter as a didactic prototype intended to support courses on electric circuit analysis experimentally. The corresponding mathematical model is obtained, the converter is designed and an experimental setup is described, constructed and tested. Simplicity of construction as well as low cost of components renders the feasible introduction of this equipment in undergraduate laboratories. (paper)

  3. Differences in gender performance on competitive physics selection tests

    Kate Wilson; David Low; Matthew Verdon; Alix Verdon

    2016-01-01

    [This paper is part of the Focused Collection on Gender in Physics.] We have investigated gender differences in performance over the past eight years on the Australian Science Olympiad Exam (ASOE) for physics, which is taken by nearly 1000 high school students each year. The ASOE, run by Australian Science Innovations (ASI), is the initial stage of the process of selection of teams to represent Australia at the Asian and International Physics Olympiads. Students taking the exam are generally ...

  4. Selected Test Results from the Encell Technology Nickel Iron Battery

    Ferreira, Summer Kamal Rhodes [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States). Advanced Power Sources R& D; Baca, Wes Edmund [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States). Advanced Power Sources R& D; Avedikian, Kristan [Encell Technology, Alachua, FL (United States)

    2014-09-01

    The performance of the Encell Nickel Iron (NiFe) battery was measured. Tests included capacity, capacity as a function of rate, capacity as a function of temperature, charge retention (28-day), efficiency, accelerated life projection, and water refill evaluation. The goal of this work was to evaluate the general performance of the Encell NiFe battery technology for stationary applications and demonstrate the chemistry's capabilities in extreme conditions. Test results have indicated that the Encell NiFe battery technology can provide power levels up to the 6C discharge rate, ampere-hour efficiency above 70%. In summary, the Encell batteries have met performance metrics established by the manufacturer. Long-term cycle tests are not included in this report. A cycle test at elevated temperature was run, funded by the manufacturer, which Encell uses to predict long-term cycling performance, and which passed their prescribed metrics.

  5. Diagnostic validation of selected serological tests for detecting scrub typhus.

    Koraluru, Munegowda; Bairy, Indira; Varma, Muralidhar; Vidyasagar, Sudha

    2015-07-01

    Clinical diagnosis of scrub typhus is often difficult because the symptoms are very similar to those of other febrile illness such as dengue, leptospirosis, malaria and other viral hemorrhagic fevers. Though better diagnostic tests are available for rickettsial diseases and scrub typhus elsewhere, the Weil-Felix test is still commonly used in India, mainly because microimmunofluorescence assays (M-IFA) were not available in India till recently and relevant staff had insufficient training. The present study was performed to investigate the performance of M-IFA, IgM ELISA, and Weil-Felix test on 546 non-repeated serum samples from subjects suspected of having scrub typhus. One hundred and forty-three of these 546 samples were positive by M-IFA; these cases were also confirmed clinically to have scrub typhus based on their dramatic responses to doxycycline therapy. IgM ELISA was positive in 122 of the 143 M-IFA positive cases and the Weil-Felix test in 96. Though the Weil-Felix test is a heterophile agglutination test, it was found in this study to have good specificity but far too little sensitivity to use as a routine diagnostic test. IgM ELISA can be a good substitute for M-IFA. Incorporation of multiple prototype antigens on M-IFA slides is likely one of the reasons for its superior performance. As newer and better diagnostic assays become available for scrub typhus diagnosis in developed countries, it will be imperative to also use such tests in other endemic countries to prevent over- or under-diagnosis of scrub typhus. © 2015 The Societies and Wiley Publishing Asia Pty Ltd.

  6. 40 CFR 205.160-2 - Test sample selection and preparation.

    2010-07-01

    ... 40 Protection of Environment 24 2010-07-01 2010-07-01 false Test sample selection and preparation... sample selection and preparation. (a) Vehicles comprising the sample which are required to be tested... maintained in any manner unless such preparation, tests, modifications, adjustments or maintenance are part...

  7. Optimizing selection of in vitro tests for diagnosing thyroid disorders

    Zwas, S.T.; Rosenblum, Yossef; Boruchowsky, Sabina

    1987-01-01

    The optimal utilization of the thyroid related radioimmunoassays T3, T4, and TSH-RIA is derived from analysing the clinical and laboratory data for 974 patients with functional thyroid disorders. A statistical computer analysis of the contribution of each of the three tests, and in combination, to the final diagnoses of hypothyroid, euthyroid, and hyper thyroid states was designed. The best contributing test for hypothyroidism and euthyroidism was TSH-RIA (98.5 and 93%, respectively). T4/T3+TSH-RIAs were the optimal dual combination for diagnosing euthyroidism (98.0%). For diagnosing hyperthyroidism T4-RIA was the best single test (82.5%) followed by T3 + T4 as an optimal dual combination (95%). Using all three tests was of no significant additional value over dual combinations. It is concluded that the work and cost of randomly performing three tests routinely is not justified without clinical basis. An algorithm is proposed to guide thyroid studies based on computer analyses of the above-mentioned single or dual-test combinations to establish accurate diagnosis at the lowest laboratory cost. (author)

  8. Drilling history core hole DC-4

    1978-12-01

    Core hole DC-4 was completed at a depth of 3998 feet in December, 1978 by Boyles Brothers Drilling Company, Spokane, Washington, under subcontract to Fenix and Scission, Inc. The hole was cored for the US Department of Energy and the Rockwell Hanford Operations' Basalt Waste Isolation Program. Fenix and Sicsson, Inc. furnished the engineering, daily supervision of the cable tool and core drilling activities, and geological core logging for DC-4. Core hole DC-4 is located on the Hanford Site about 3 miles east of the Yakima Barricade and approximately 103 feet southwest of rotary hole DC-5, which was completed to 3990 feet in February, 1978. Hanford Site coordinates reported for hole DC-4 are north 49,385.62 feet and west 85,207.63 feet, and Washington State coordinates are north 454,468.73 feet and east 2,209,990.87 feet. No elevation survey is available for hole DC-4, but it is approximately 745 feet above mean sea level based upon the survey of hole DC-5, which has a reported elevation of 745.16 feet on the top of the 3-inch flange. The purpose of core hole DC-4 was to core drill vertically through the basalt and interbed units for stratigraphic depth determination and core collection, and to provide a borehole for hydrologic testing, cross-hole seismic shear, and pressure wave velocity studies with rotary hole DC-5. Hole DC-4 was drilled through the overburden into basalt bedrock by cable tool methods (0-623 feet) and continuously cored through the final interval (623 to 3998 feet).Core recovery was 95.8 percent of the total footage cored

  9. Specificity and sensitivity assessment of selected nasal provocation testing techniques

    Edyta Krzych-Fałta

    2016-12-01

    Full Text Available Introduction: Nasal provocation testing involves an allergen-specific local reaction of the nasal mucosa to the administered allergen. Aim: To determine the most objective nasal occlusion assessment technique that could be used in nasal provocation testing. Material and methods : A total of 60 subjects, including 30 patients diagnosed with allergy to common environmental allergens and 30 healthy subjects were enrolled into the study. The method used in the study was a nasal provocation test with an allergen, with a standard dose of a control solution and an allergen (5,000 SBU/ml administered using a calibrated atomizer into both nostrils at room temperature. Early-phase nasal mucosa response in the early phase of the allergic reaction was assessed via acoustic rhinometry, optical rhinometry, nitric oxide in nasal air, and tryptase levels in the nasal lavage fluid. Results : In estimating the homogeneity of the average values, the Levene’s test was used and receiver operating characteristic curves were plotted for all the methods used for assessing the nasal provocation test with an allergen. Statistically significant results were defined for p < 0.05. Of all the objective assessment techniques, the most sensitive and characteristic ones were the optical rhinometry techniques (specificity = 1, sensitivity = 1, AUC = 1, PPV = 1, NPV = 1. Conclusions : The techniques used showed significant differences between the group of patients with allergic rhinitis and the control group. Of all the objective assessment techniques, those most sensitive and characteristic were the optical rhinometry.

  10. Allelopathic effects of the invasive Prosopis juliflora (Sw. DC. on selected native plant species in Middle Awash, Southern Afar Rift of Ethiopia

    Samuel Getachew

    2012-12-01

    Full Text Available The allelopathic effects of the invasive Prosopis juliflora (Sw. DC. was studied on seed germination and seedling growth of Acacia nilotica(L. Willd. ex Del., Acacia tortilis (Forssk. Hayne, Cenchrus ciliaris L. and Enteropogon rupestris (J.A. Schmidt A. Chev. Vegetation sampling in different habitat types in the area was made to identify the target plant species. Comparison of canopy characteristics among P. juliflora, A. nilotica and A. tortilis was also made to observe differences if any in canopy closure. P. juliflora was recorded in all habitat types in highest density and observed affecting the plant diversity there in. Its growth characteristics and dense thicket formation restrict light to the ground flora and hence diminishes plant diversity. Leaf, bark and root aqueous extract of P. juliflora at 0, 0.5, 0.8, 1, 2 and 6% wereprepared and their effect studied on germination percentage and seedling growth of the study plant species. Germination of A. nilotica and A. tortilis was not affected by all aqueous extracts of different organ parts of P. juliflora while leaf and root extracts at higher concentrations inhibited germination of C. ciliaris and E. rupestris. Shoot and root growth of the study species were inhibited by leaf and root at higher concentrations. Seed germination of all species except A. nilotica was inhibited by soil amended with decaying plant parts and under canopy soil. The effect is species specific and annuals (grasses and herbs were affected more than perennials. Leaf seems to contain greater number/amount of inhibitors than does root and bark. Bark seems to contain the least. Heavy accumulation of toxic substances at under canopy soil of P. juliflora may be one of the reasons for its invasiveness and low plant diversity.

  11. TESTING FOR PURCHASING POWER PARITY FOR SELECTED CISCOUNTRIES

    Arş. Gör. Esra Ballı

    2016-07-01

    Full Text Available This study examines the validity of PPP for Commonwealth of Independent States(CIS namely Armenia, Azerbaijan, Belarus, Kazakhstan, Kyrgyzstan, Russia andUkraine for the period 1995M1-2015M11. In this study we perform stationary teston twobases. In the first place, we initiate conventional unit root test such asADF. Secondly, we utilize unit root tests allowing for structural break. Given thespan and characteristics of the period which involves a significant break such as1998 Russian economic crisis, we conclude that PPP holds for Armenia, Belarus,Kazakhstan and Kyrgyzstan, while it does not hold for Azerbaijan, Russia andUkraine.

  12. Testing music selection automation possibilities for video ads

    Wiesener Oliver

    2017-09-01

    Full Text Available The importance of video ads on social media platforms can be measured by the number of views. For instance, Samsung’s commercial ad for one of its new smartphones reached more than 46 million viewers at Youtube. Video ads address users both visually and aurally. Often, the visual sense is engaged by users focusing on other screens, rather than on the screen with the video ad, which is referred to as the second screen syndrome. Therefore, the importance of the audio channel seems to gain more importance. To get back the visual attention of users that are deflected from other visual impulses it appears reasonable to adapt the music to the target group. Additionally, it appears useful to adapt the music to the content of the video. Thus, the overall success of a video ad could be improved by increasing the attention of the users. Humans typically decide which music is to be used in a video ad. If there is a correlation between music, products and target groups, a digitization of the music selection process appears to be possible. Since the digitization progress in the music sector is currently mainly focused on music composing this article strives for taking a first step towards the digitization of the music selection.

  13. Bidirectional dc-to-dc Power Converter

    Griesbach, C. R.

    1986-01-01

    Solid-state, series-resonant converter uses high-voltage thyristors. Converter used either to convert high-voltage, low-current dc power to lowvoltage, high current power or reverse. Taking advantage of newly-available high-voltage thyristors to provide better reliability and efficiency than traditional converters that use vacuum tubes as power switches. New converter essentially maintenance free and provides greatly increased mean time between failures. Attractive in industrial applications whether or not bidirectional capability is required.

  14. Analysis of selected Halden overpressure tests using the FALCON code

    Khvostov, G., E-mail: grigori.khvostov@psi.ch [Paul Scherrer Institut, CH 5232 Villigen PSI (Switzerland); Wiesenack, W. [Institute for Energy Technology – OECD Halden Reactor Project, P.O. Box 173, N-1751 Halden (Norway)

    2016-12-15

    Highlights: • We analyse four Halden overpressure tests. • We determine a critical overpressure value for lift-off in a BWR fuel sample. • We show the role of bonding in over-pressurized rod behaviour. • We analytically quantify the degree of bonding via its impact on cladding elongation. • We hypothesize on an effect of circumferential cracks on thermal fuel response to overpressure. • We estimate a thermal effect of circumferential cracks based on interpretation of the data. - Abstract: Four Halden overpressure (lift-off) tests using samples with uranium dioxide fuel pre-irradiated in power reactors to a burnup of 60 MWd/kgU are analyzed. The FALCON code coupled to a mechanistic model, GRSW-A for fission gas release and gaseous-bubble swelling is used for the calculation. The advanced version of the FALCON code is shown to be applicable to best-estimate predictive analysis of overpressure tests using rods without, or weak pellet-cladding bonding, as well as scoping analysis of tests with fuels where stronger pellet-cladding bonding occurs. Significant effects of bonding and fuel cracking/relocation on the thermal and mechanical behaviour of highly over-pressurized rods are shown. The effect of bonding is particularly pronounced in the tests with the PWR samples. The present findings are basically consistent with an earlier analysis based on a direct interpretation of the experimental data. Additionally, in this paper, the specific effects are quantified based on the comparison of the data with the results of calculation. It is concluded that the identified effects are largely beyond the current traditional fuel-rod licensing analysis methods.

  15. Reduction of DC-link Capacitor in Case of Cascade Multilevel Converters by means of Reactive Power Control

    Gohil, Ghanshyamsinh Vijaysinh; Wang, Huai; Liserre, Marco

    2014-01-01

    A method to selectively control the amount of dc link voltage ripple by processing desired reactive power by a DC/DC converter in isolated AC/DC or AC/DC/AC system is proposed. The concept can reduce the dc link capacitors used for balancing the input and output power and thereby limiting...... the voltage ripple. It allows the use of smaller dc link capacitor and hence a longer lifetime and at the same time high power density and low cost can be achieved. The isolated DC/DC converter is controlled to process the desired reactive power in addition to the active power. The control system to achieve...

  16. A Cancer Gene Selection Algorithm Based on the K-S Test and CFS

    Qiang Su

    2017-01-01

    Full Text Available Background. To address the challenging problem of selecting distinguished genes from cancer gene expression datasets, this paper presents a gene subset selection algorithm based on the Kolmogorov-Smirnov (K-S test and correlation-based feature selection (CFS principles. The algorithm selects distinguished genes first using the K-S test, and then, it uses CFS to select genes from those selected by the K-S test. Results. We adopted support vector machines (SVM as the classification tool and used the criteria of accuracy to evaluate the performance of the classifiers on the selected gene subsets. This approach compared the proposed gene subset selection algorithm with the K-S test, CFS, minimum-redundancy maximum-relevancy (mRMR, and ReliefF algorithms. The average experimental results of the aforementioned gene selection algorithms for 5 gene expression datasets demonstrate that, based on accuracy, the performance of the new K-S and CFS-based algorithm is better than those of the K-S test, CFS, mRMR, and ReliefF algorithms. Conclusions. The experimental results show that the K-S test-CFS gene selection algorithm is a very effective and promising approach compared to the K-S test, CFS, mRMR, and ReliefF algorithms.

  17. Hanford tank initiative test facility site selection study

    Staehr, T.W.

    1997-01-01

    The Hanford Tanks Initiative (HTI) project is developing equipment for the removal of hard heel waste from the Hanford Site underground single-shell waste storage tanks. The HTI equipment will initially be installed in the 241-C-106 tank where its operation will be demonstrated. This study evaluates existing Hanford Site facilities and other sites for functional testing of the HTI equipment before it is installed into the 241-C-106 tank

  18. A DC Transformer

    National Aeronautics and Space Administration — The goal of the project was to demonstrate a true direct current (DC) transformer, a new electro-mechanical component with potentially high power applications; in...

  19. Hole history, rotary hole DC-3

    1977-10-01

    Purpose of hole DC-3 was to drill into the Umtanum basalt flow using both conventional rotary and core drilling methods. The borehole is to be utilized for geophysical logging, future hydrological testing, and the future installation of a borehole laboratory for long-term pressure, seismic, and moisture migration or accumulation recording in the Umtanum basalt flow in support of the Basalt Waste Isolation Program. Hole DC-3 is located east of the 200 West barricaded area on the Hanford reservation

  20. Analysis of dc-Link Voltage Switching Ripple in Three-Phase PWM Inverters

    Marija Vujacic

    2018-02-01

    Full Text Available The three-phase voltage source inverter (VSI is de facto standard in power conversion systems. To realize high power density systems, one of the items to be correctly addressed is the design and selection of the dc-link capacitor in relation to the voltage switching ripple. In this paper, effective formulas for designing the dc-link capacitor as a function of the switching voltage ripple amplitude are obtained, considering the operating conditions such as the modulation index and the output current amplitude. The calculations are obtained considering the requirements and restrictions referring to the high (switching-frequency dc-link voltage ripple component. Analyses have been performed considering the dc source impedance (non-ideal dc voltage source at the switching frequency and a balanced load. Analytical expressions are derived for the dc-link voltage switching ripple amplitude and its maximum value over the fundamental period. Different values of modulation index and output phase angle have been considered and different diagrams are presented. Analytical results were validated both by simulations and comprehensive experimental tests.

  1. Evaluation: Processes and Practices. Selected Papers from the Conference for the Evaluation of Instructional Materials (Washington, D.C., April 5-6, 1968).

    Swisher, Ginny, Ed.; And Others

    Selected papers from the Conference for the Evaluation of Instructional Materials treat the area of evaluation by describing Richard Dershimer's three-part evaluative schema, the Educational Products Information Exchange approach to evaluating instructional materials, the evaluation procedures in Montgomery county (Maryland), the Consumers Union…

  2. ADM guidance-Ceramics: Fracture toughness testing and method selection.

    Cesar, Paulo Francisco; Della Bona, Alvaro; Scherrer, Susanne S; Tholey, Michael; van Noort, Richard; Vichi, Alessandro; Kelly, Robert; Lohbauer, Ulrich

    2017-06-01

    The objective is within the scope of the Academy of Dental Materials Guidance Project, which is to provide dental materials researchers with a critical analysis of fracture toughness (FT) tests such that the assessment of the FT of dental ceramics is conducted in a reliable, repeatable and reproducible way. Fracture mechanics theory and FT methodologies were critically reviewed to introduce basic fracture principles and determine the main advantages and disadvantages of existing FT methods from the standpoint of the dental researcher. The recommended methods for FT determination of dental ceramics were the Single Edge "V" Notch Beam (SEVNB), Single Edge Precracked Beam (SEPB), Chevron Notch Beam (CNB), and Surface Crack in Flexure (SCF). SEVNB's main advantage is the ease of producing the notch via a cutting disk, SEPB allows for production of an atomically sharp crack generated by a specific precracking device, CNB is technically difficult, but based on solid fracture mechanics solutions, and SCF involves fracture from a clinically sized precrack. The IF test should be avoided due to heavy criticism that has arisen in the engineering field regarding the empirical nature of the calculations used for FT determination. Dental researchers interested in FT measurement of dental ceramics should start with a broad review of fracture mechanics theory to understand the underlying principles involved in fast fracture of ceramics. The choice of FT methodology should be based on the pros and cons of each test, as described in this literature review. Copyright © 2017 The Academy of Dental Materials. Published by Elsevier Ltd. All rights reserved.

  3. A measurement method for determination of dc internal resistance of batteries and supercapacitors

    Zhao, Shuhong; Wu, Feng [Department of Materials Science, Beijing Science and Technology University, Beijing 100081 (China); Yang, Liuxiang; Gao, Lijun [Department of Chemistry, NanChang University, JiangXi 330031 (China); Burke, Andrew F. [Institute of Transportation, University of California, Davis, CA 95616 (United States)

    2010-02-15

    Internal resistance is an importance parameter determining the power performance of a battery or supercapacitor. An 8.5 Ah Li-ion battery and a 350 F supercapacitor were tested as examples to validate the measurement method of dc internal resistance. Voltage data were taken at 10 ms, 2 s and 30 s after the current interruption or pulse. The ac resistances at 1 kHz of the battery and supercapacitor were also measured for comparison with the dc values. Based on these tests, it is proposed that the dc internal resistance of the battery and supercapacitor be obtained from {delta}V/{delta}I where the {delta}V is the voltage change after the current interruption, and {delta}I means current change from I to 0. When the voltage change at 10 ms or less is selected, the resistance corresponds to the Ohmic resistance of the device. (author)

  4. Digital DC beam current measurement on SSRF storage ring

    Xiong Liang; Yin Chongxian; Liu Ming; Chen Jianfeng

    2011-01-01

    Both DC current transformer (DCCT) and integrating current transformer (ICT) can be used in DC beam current measurement. The ICT has strong capability of resisting electromagnetic interference, but its measurement accuracy cannot satisfy the DC beam current measurement requirement when using traditional high speed A/D. With high resolution A/D and equivalent sampling system, DC beam current measuring system based on ICT can reach high accuracy compared with DCCT system. In this paper, the ICT-based DC beam current measurement, equivalent sampling method and testing results at Shanghai Synchrotron Radiation Facility(SSRF) is described. (authors)

  5. Three new DC-to-DC Single-Switch Converters

    Barry W. Williams

    2017-06-01

    Full Text Available This paper presents a new family of three previously unidentified dc-to-dc converters, buck, boost, and buck-boost voltage-transfer-function topologies, which offer advantageous transformer coupling features and low capacitor dc voltage stressing. The three single-switch, single-diode, converters offer the same features as basic dc-to-dc converters, such as the buck function with continuous output current and the boost function with continuous input current. Converter time-domain simulations and experimental results (including transformer coupling support and extol the dc-to-dc converter concepts and analysis presented.

  6. Statistical Redundancy Testing for Improved Gene Selection in Cancer Classification Using Microarray Data

    J. Sunil Rao

    2007-01-01

    Full Text Available In gene selection for cancer classifi cation using microarray data, we define an eigenvalue-ratio statistic to measure a gene’s contribution to the joint discriminability when this gene is included into a set of genes. Based on this eigenvalueratio statistic, we define a novel hypothesis testing for gene statistical redundancy and propose two gene selection methods. Simulation studies illustrate the agreement between statistical redundancy testing and gene selection methods. Real data examples show the proposed gene selection methods can select a compact gene subset which can not only be used to build high quality cancer classifiers but also show biological relevance.

  7. 40 CFR 205.171-2 - Test exhaust system sample selection and preparation.

    2010-07-01

    ... Systems § 205.171-2 Test exhaust system sample selection and preparation. (a)(1) Exhaust systems... 40 Protection of Environment 24 2010-07-01 2010-07-01 false Test exhaust system sample selection and preparation. 205.171-2 Section 205.171-2 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY...

  8. The predictive validity of personality tests in air traffic controller selection

    Roe, R.A.; Oprins, E.A.P.B.; Geven, E.

    2012-01-01

    A brief historical review of test methods used for selecting air traffic controllers (ATCOs) shows that in contrast to e.g. ability tests and job samples, personality tests have been used rather infrequently. The lesser popularity of personality tests may be explained from the belief that

  9. Assessment of the quality of test results from selected civil engineering material testing laboratories in Tanzania

    Mbawala, SJ

    2017-12-01

    Full Text Available Civil and geotechnical engineering material testing laboratories are expected to produce accurate and reliable test results. However, the ability of laboratories to produce accurate and reliable test results depends on many factors, among others...

  10. Research on key technology of planning and design for AC/DC hybrid distribution network

    Shen, Yu; Wu, Guilian; Zheng, Huan; Deng, Junpeng; Shi, Pengjia

    2018-04-01

    With the increasing demand of DC generation and DC load, the development of DC technology, AC and DC distribution network integrating will become an important form of future distribution network. In this paper, the key technology of planning and design for AC/DC hybrid distribution network is proposed, including the selection of AC and DC voltage series, the design of typical grid structure and the comprehensive evaluation method of planning scheme. The research results provide some ideas and directions for the future development of AC/DC hybrid distribution network.

  11. A probabilistic method for testing and estimating selection differences between populations.

    He, Yungang; Wang, Minxian; Huang, Xin; Li, Ran; Xu, Hongyang; Xu, Shuhua; Jin, Li

    2015-12-01

    Human populations around the world encounter various environmental challenges and, consequently, develop genetic adaptations to different selection forces. Identifying the differences in natural selection between populations is critical for understanding the roles of specific genetic variants in evolutionary adaptation. Although numerous methods have been developed to detect genetic loci under recent directional selection, a probabilistic solution for testing and quantifying selection differences between populations is lacking. Here we report the development of a probabilistic method for testing and estimating selection differences between populations. By use of a probabilistic model of genetic drift and selection, we showed that logarithm odds ratios of allele frequencies provide estimates of the differences in selection coefficients between populations. The estimates approximate a normal distribution, and variance can be estimated using genome-wide variants. This allows us to quantify differences in selection coefficients and to determine the confidence intervals of the estimate. Our work also revealed the link between genetic association testing and hypothesis testing of selection differences. It therefore supplies a solution for hypothesis testing of selection differences. This method was applied to a genome-wide data analysis of Han and Tibetan populations. The results confirmed that both the EPAS1 and EGLN1 genes are under statistically different selection in Han and Tibetan populations. We further estimated differences in the selection coefficients for genetic variants involved in melanin formation and determined their confidence intervals between continental population groups. Application of the method to empirical data demonstrated the outstanding capability of this novel approach for testing and quantifying differences in natural selection. © 2015 He et al.; Published by Cold Spring Harbor Laboratory Press.

  12. Testing for biases in selection on avian reproductive traits and partitioning direct and indirect selection using quantitative genetic models.

    Reed, Thomas E; Gienapp, Phillip; Visser, Marcel E

    2016-10-01

    Key life history traits such as breeding time and clutch size are frequently both heritable and under directional selection, yet many studies fail to document microevolutionary responses. One general explanation is that selection estimates are biased by the omission of correlated traits that have causal effects on fitness, but few valid tests of this exist. Here, we show, using a quantitative genetic framework and six decades of life-history data on two free-living populations of great tits Parus major, that selection estimates for egg-laying date and clutch size are relatively unbiased. Predicted responses to selection based on the Robertson-Price Identity were similar to those based on the multivariate breeder's equation (MVBE), indicating that unmeasured covarying traits were not missing from the analysis. Changing patterns of phenotypic selection on these traits (for laying date, linked to climate change) therefore reflect changing selection on breeding values, and genetic constraints appear not to limit their independent evolution. Quantitative genetic analysis of correlational data from pedigreed populations can be a valuable complement to experimental approaches to help identify whether apparent associations between traits and fitness are biased by missing traits, and to parse the roles of direct versus indirect selection across a range of environments. © 2016 The Author(s). Evolution © 2016 The Society for the Study of Evolution.

  13. Genetic tests in work place from the preventive selection to selective prevention

    Poissonnet, C.M.; Veron, M.

    2004-01-01

    The research in this area allows to better understand the mechanisms of illness trigger, to improve the knowledge in the relation exposure-illness, to detect the risk associated to low exposure among some particularly sensitive persons and to define the validity criteria. Inevitably these researches reach to define the most vulnerable persons. This designation could be a factor favorable to the prevention and to give a better sense of responsibility. The worker, well informed, can be particularly concerned by wearing the individual protections, and the person in charge of the installation by looking to reduce exposure. It can be also deviate and corresponds to a real discrimination with rejection of sensitive persons and selection of resistant individuals with which it could be possible to work in non optimal conditions. The problem is at this level the conflicts of interest exist between these ones that dream to use this possibility wisely and that ones for which the interests are elsewhere. (N.C.)

  14. Statistical test data selection for reliability evalution of process computer software

    Volkmann, K.P.; Hoermann, H.; Ehrenberger, W.

    1976-01-01

    The paper presents a concept for converting knowledge about the characteristics of process states into practicable procedures for the statistical selection of test cases in testing process computer software. Process states are defined as vectors whose components consist of values of input variables lying in discrete positions or within given limits. Two approaches for test data selection, based on knowledge about cases of demand, are outlined referring to a purely probabilistic method and to the mathematics of stratified sampling. (orig.) [de

  15. Three-port DC-DC converter with new integrated transformer for DC Distribution Systems

    Ouyang, Ziwei; Andersen, Michael A. E.

    2014-01-01

    A new integrated transformer for three-port dc-dc converter is proposed to overcome the power coupling effect existed in some known multiple inputs dc-dc converters. Orthogonal primary windings arrangement and in series connection of diagonal secondary Windings enables a fully power decoupling...

  16. 75 FR 23571 - Airworthiness Directives; McDonnell Douglas Corporation Model DC-10-10, DC-10-10F, DC-10-15, DC...

    2010-05-04

    ... Airworthiness Directives; McDonnell Douglas Corporation Model DC- 10-10, DC-10-10F, DC-10-15, DC-10-30, DC-10... amends Sec. 39.13 by adding the following new AD: 2010-09-12 McDonnell Douglas Corporation: Amendment 39... to McDonnell Douglas Corporation Model DC- 10-10, DC-10-10F, DC-10-15, DC-10-30, DC-10-30F (KC-10A...

  17. ZVS Operating Region of Multiresonant DC/DC Boost Conveter

    Elzbieta Szychta

    2007-01-01

    Full Text Available Electromagnetic phenomena that occur during stable operation in resonant circuits of multiresonant ZVS boost converter are described, which can be applied in many fields of the needs of DC voltage electricity. The operating region of the converter is defined which assures the circuit’s operation in which semiconductor elements are switched at zero voltage (ZVS. Conditions delimiting the ZVS operating region are provided. Analysis of the circuit’s operation is based on results of simulation testing by means of Simplorer software.

  18. Autonomous Control Strategy of DC Microgrid for Islanding Mode Using Power Line Communication

    Dong-Keun Jeong

    2018-04-01

    Full Text Available This paper proposes a DC-bus signaling (DBS method for autonomous power management in a DC microgrid, used to improve its reliability. Centralized power management systems require communication between the power sources and loads. However, the DBS method operates based on the common DC-bus voltage and does not require communication. Based on the DC-bus voltage band, the DC-bus voltage can be used to inform the status of the DC-bus in various scenarios. The DC microgrid operates independently to maintain the system stably in the DC-bus voltage band. The DC microgrid can be divided into a grid-connected mode and an islanding mode. This paper proposes a control strategy based on power management of various independent components in islanding mode. In addition, the autonomous control method for switching the converter’s operation between grid-connected mode and islanding mode is proposed. A DC microgrid test bed consisting of a grid-connected AC/DC converter, a bidirectional DC/DC converter, a renewable energy simulator, DC home appliances and a DC-bus protector is used to test the proposed control strategy. The proposed autonomous control strategy is experimentally verified using the DC microgrid test bed.

  19. Control of improved full-bridge three-level DC/DC converter for wind turbines in a DC grid

    Deng, Fujin; Chen, Zhe

    2013-01-01

    transformer in the IFBTL dc/dc converter. A modulation strategy, including two operation modes, is proposed for the IFBTL dc/dc converter. Then, a voltage balancing control strategy is proposed for the IFBTL dc/dc converter. Furthermore, the control of the wind turbine based on the IFBTL dc/dc converter......This paper presents an improved full-bridge three-level (IFBTL) dc/dc converter for a wind turbine in a dc grid by inserting a passive filter into the dc/dc converter to improve the performance of the converter. The passive filter can effectively reduce the voltage stress of the medium frequency...

  20. Tests of selection in pooled case-control data: an empirical study.

    Udpa, Nitin; Zhou, Dan; Haddad, Gabriel G; Bafna, Vineet

    2011-01-01

    For smaller organisms with faster breeding cycles, artificial selection can be used to create sub-populations with different phenotypic traits. Genetic tests can be employed to identify the causal markers for the phenotypes, as a precursor to engineering strains with a combination of traits. Traditional approaches involve analyzing crosses of inbred strains to test for co-segregation with genetic markers. Here we take advantage of cheaper next generation sequencing techniques to identify genetic signatures of adaptation to the selection constraints. Obtaining individual sequencing data is often unrealistic due to cost and sample issues, so we focus on pooled genomic data. We explore a series of statistical tests for selection using pooled case (under selection) and control populations. The tests generally capture skews in the scaled frequency spectrum of alleles in a region, which are indicative of a selective sweep. Extensive simulations are used to show that these approaches work well for a wide range of population divergence times and strong selective pressures. Control vs control simulations are used to determine an empirical False Positive Rate, and regions under selection are determined using a 1% FPR level. We show that pooling does not have a significant impact on statistical power. The tests are also robust to reasonable variations in several different parameters, including window size, base-calling error rate, and sequencing coverage. We then demonstrate the viability (and the challenges) of one of these methods in two independent Drosophila populations (Drosophila melanogaster) bred under selection for hypoxia and accelerated development, respectively. Testing for extreme hypoxia tolerance showed clear signals of selection, pointing to loci that are important for hypoxia adaptation. Overall, we outline a strategy for finding regions under selection using pooled sequences, then devise optimal tests for that strategy. The approaches show promise for

  1. Women and Educational Testing: A Selective Review of the Research Literature and Testing Practices.

    Tittle, Carol Kehr; And Others

    This report provides an exploratory survey of several aspects of educational testing, with a view toward identifying discrimination against women. Two major ways in which discrimination can occur are examined in educational testing: reinforcement of sex-role stereotypes and restriction of individual choice. Major educational achievement tests are…

  2. Overview of Multi-DC-Bus Solutions for DC Microgrids

    Ricchiuto, D.; Mastromauro, R.A.; Liserre, Marco

    2013-01-01

    DC Microgrids have recently received a lot of attention in the last years due to high penetration of renewable energy sources as well as distributed energy storage systems. In the future DC microgrids could be preferable respect to AC microgrids in terms of redundancy since multi-DC-Bus solutions...... could provide a continuative power supply to the loads. An overview of Multi-DC-Bus solutions is presented in this paper. The performances are compared on the basis of possible DC microgrid configurations, redundancy, different DC voltage levels....

  3. An Improved Test Selection Optimization Model Based on Fault Ambiguity Group Isolation and Chaotic Discrete PSO

    Xiaofeng Lv

    2018-01-01

    Full Text Available Sensor data-based test selection optimization is the basis for designing a test work, which ensures that the system is tested under the constraint of the conventional indexes such as fault detection rate (FDR and fault isolation rate (FIR. From the perspective of equipment maintenance support, the ambiguity isolation has a significant effect on the result of test selection. In this paper, an improved test selection optimization model is proposed by considering the ambiguity degree of fault isolation. In the new model, the fault test dependency matrix is adopted to model the correlation between the system fault and the test group. The objective function of the proposed model is minimizing the test cost with the constraint of FDR and FIR. The improved chaotic discrete particle swarm optimization (PSO algorithm is adopted to solve the improved test selection optimization model. The new test selection optimization model is more consistent with real complicated engineering systems. The experimental result verifies the effectiveness of the proposed method.

  4. 40 CFR 1045.310 - How must I select engines for production-line testing?

    2010-07-01

    ... select and test one more engine. Then, calculate the required sample size for the model year as described.... It defines 95% confidence intervals for a one-tail distribution. σ = Test sample standard deviation (see paragraph (c)(2) of this section). x = Mean of emission test results of the sample. STD = Emission...

  5. Testing of Selective Laser Melting Turbomachinery Applicable to Exploration Upper Stage

    Calvert, Marty; Turpin, Jason; Nettles, Mindy

    2015-01-01

    This task is to design, fabricate, and spin test to failure a Ti6-4 hydrogen turbopump impeller that was built using the selective laser melting (SLM) fabrication process (fig. 1). The impeller is sized around upper stage engine requirements. In addition to the spin burst test, material testing will be performed on coupons that are built with the impeller.

  6. Homopolar dc motor and trapped flux brushless dc motor using high temperature superconductor materials

    Crapo, Alan D.; Lloyd, Jerry D.

    1991-03-01

    Two motors have been designed and built for use with high-temperature superconductor (HTSC) materials. They are a homopolar dc motor that uses HTSC field windings and a brushless dc motor that uses bulk HTSC materials to trap flux in steel rotor poles. The HTSC field windings of the homopolar dc motor are designed to operate at 1000 A/sq cm in a 0.010-T field. In order to maximize torque in the homopolar dc motor, an iron magnetic circuit with small air gaps gives maximum flux for minimum Ampere turns in the field. A copper field winding version of the homopolar dc motor has been tested while waiting for 575 A turn HTSC coils. The trapped flux brushless dc motor has been built and is ready to test melt textured bulk HTSC rings that are currently being prepared. The stator of the trapped flux motor will impress a magnetic field in the steel rotor poles with warm HTSC bulk rings. The rings are then cooled to 77 K to trap the flux in the rotor. The motor can then operate as a brushless dc motor.

  7. Performance of 22.4-kW nonlaminated-frame dc series motor with chopper controller. [a dc to dc voltage converter

    Schwab, J. R.

    1979-01-01

    Performance data obtained through experimental testing of a 22.4 kW traction motor using two types of excitation are presented. Ripple free dc from a motor-generator set for baseline data and pulse width modulated dc as supplied by a battery pack and chopper controller were used for excitation. For the same average values of input voltage and current, the motor power output was independent of the type of excitation. However, at the same speeds, the motor efficiency at low power output (corresponding to low duty cycle of the controller) was 5 to 10 percentage points lower on chopped dc than on ripple free dc. The chopped dc locked-rotor torque was approximately 1 to 3 percent greater than the ripple free dc torque for the same average current.

  8. Selecting participants for listening tests of multi-channel reproduced sound

    Wickelmaier, Florian Maria; Choisel, Sylvain

    2005-01-01

    A selection procedure was devised in order to select listeners for experiments in which their main task will be to judge multichannel reproduced sound. Ninety-one participants filled in a web-based questionnaire. Seventy-eight of them took part in an assessment of their hearing thresholds......, their spatial hearing, and their verbal production abilities. The listeners displayed large individual differences in their performance. Forty subjects were selected based on the test results. The self-assessed listening habits and experience in the web-questionnaire could not predict the results...... of the selection procedure. Further, the hearing thresholds did not correlate with the spatial-hearing test. This leads to the conclusion that task-specific performance tests might be the preferable means of selecting a listening panel....

  9. Selecting participants for listening tests of multi-channel reproduced sound

    Wickelmaier, Florian; Choisel, Sylvain

    2005-01-01

    A selection procedure was devised in order to select listeners for experiments in which their main task will be to judge multi-channel reproduced sound. 91 participants filled in a web-based questionnaire. 78 of them took part in an assessment of their hearing thresholds, their spatial hearing......, and their verbal production abilities. The listeners displayed large individual differences in their performance. 40 subjects were selected based on the test results. The self-assessed listening habits and experience in the web questionnaire could not predict the results of the selection procedure. Further......, the hearing thresholds did not correlate with the spatial-hearing test. This leads to the conclusion that task-specific performance tests might be the preferable means of selecting a listening panel....

  10. Intersession reliability of self-selected and narrow stance balance testing in older adults.

    Riemann, Bryan L; Piersol, Kelsey

    2017-10-01

    Despite the common practice of using force platforms to assess balance of older adults, few investigations have examined the reliability of postural screening tests in this population. We sought to determine the test-retest reliability of self-selected and narrow stance balance testing with eyes open and eyes closed in healthy older adults. Thirty older adults (>65 years) completed 45 s trials of eyes open and eyes closed stability tests using self-selected and narrow stances on two separate days (1.9 ± .7 days). Average medial-lateral center of pressure velocity was computed. The ICC results ranged from .74 to .86, and no significant systematic changes (P eyes open and closed balance testing using self-selected and narrow stances in older adults was established which should provide a foundation for the development of fall risk screening tests.

  11. DISCRIMINATIVE ANALYSIS OF TESTS FOR EVALUATING SITUATIONMOTORIC ABILITIES BETWEEN TWO GROUPS OF BASKETBALL PLAYERS SELECTED BY THE TEST OF SOCIOMETRY

    Abdulla Elezi; Nazim Myrtaj; Florian Miftari

    2011-01-01

    Determining differences between the two groups of basketball players selected with the modified sociometric test (Paranosić and Lazarević) in some tests for assessing situation-motor skills, was the aim of this work. The test sample was consisted of 20 basketball players who had most positive points and 20 basketball players who had most negative points, in total- 40 players. T-test was applied to determine whether there are differences between the two groups of basketball players who had bee...

  12. Influence of selected test parameters on measured values during the MSCR test

    Benešová, Lucie; Valentin, Jan

    2017-09-01

    One of today’s most commonly used test on a Dynamic Shear Rheometer (DSR) is the Multiple Stress Creep Recovery (MSCR) test. The test is described in the standard EN 16659, which is valid in the Czech Republic since October 2016. The principle of the test is based on repeated loading and recovering of a bitumen sample, according to which it is possible to determine the percentage of elastic recovery (R) and non-recoverable creep compliance (Jnr) of the bituminous binder. This method has been recently promoted as the most suitable test for assessing the resistance of bituminous binders to permanent deformation. The test is performed at higher temperatures and is particularly suitable for modified bituminous binders. The paper deals with the comparison of the different input parameters set on the DSR device - different levels of stress, temperature of test, the geometry of the measuring device and also a comparison of the results for a different number of loading cycles. The research study was focused mainly on modified bituminous binders, but to compare the MSCR test it is performed even with conventional paving grade binders.

  13. Selecting a Response in Task Switching: Testing a Model of Compound Cue Retrieval

    Schneider, Darryl W.; Logan, Gordon D.

    2009-01-01

    How can a task-appropriate response be selected for an ambiguous target stimulus in task-switching situations? One answer is to use compound cue retrieval, whereby stimuli serve as joint retrieval cues to select a response from long-term memory. In the present study, the authors tested how well a model of compound cue retrieval could account for a…

  14. A Feedback Control Strategy for Enhancing Item Selection Efficiency in Computerized Adaptive Testing

    Weissman, Alexander

    2006-01-01

    A computerized adaptive test (CAT) may be modeled as a closed-loop system, where item selection is influenced by trait level ([theta]) estimation and vice versa. When discrepancies exist between an examinee's estimated and true [theta] levels, nonoptimal item selection is a likely result. Nevertheless, examinee response behavior consistent with…

  15. Behavioral profiles of genetically selected aggressive and nonaggressive male wild house mice in two anxiety tests

    Hogg, S; Wurbel, H; Steimer, T; de Ruiter, A; Koolhaas, J; Sluyter, F; Driscoll, Peter

    2000-01-01

    Artificially selected aggressive (SAL) and non-aggressive (LAL) male house mice were tested in a hexagonal tunnel maze and light-dark preference (LD) box to determine if the bidirectional selection for aggressive behavior leads to a coselection for different levels of trait anxiety. The tunnel maze

  16. dc Arc Fault Effect on Hybrid ac/dc Microgrid

    Fatima, Zahra

    The advent of distributed energy resources (DER) and reliability and stability problems of the conventional grid system has given rise to the wide spread deployment of microgrids. Microgrids provide many advantages by incorporating renewable energy sources and increasing the reliability of the grid by isolating from the main grid in case of an outage. AC microgrids have been installed all over the world, but dc microgrids have been gaining interest due to the advantages they provide over ac microgrids. However the entire power network backbone is still ac and dc microgrids require expensive converters to connect to the ac power network. As a result hybrid ac/dc microgrids are gaining more attention as it combines the advantages of both ac and dc microgrids such as direct integration of ac and dc systems with minimum number of conversions which increases the efficiency by reducing energy losses. Although dc electric systems offer many advantages such as no synchronization and no reactive power, successful implementation of dc systems requires appropriate protection strategies. One unique protection challenge brought by the dc systems is dc arc faults. A dc arc fault is generated when there is a gap in the conductor due to insulation degradation and current is used to bridge the gap, resulting in an arc with very high temperature. Such a fault if it goes undetected and is not extinguished can cause damage to the entire system and cause fires. The purpose of the research is to study the effect of the dc arc fault at different locations in the hybrid ac/dc microgrid and provide insight on the reliability of the grid components when it is impacted by arc faults at various locations in the grid. The impact of dc arc fault at different locations on the performance of the PV array, wind generation, and constant power loads (CPL) interfaced with dc/dc converters is studied. MATLAB/Simulink is used to model the hybrid ac/dc microgrid and arc fault.

  17. Is it better to select or to receive? Learning via active and passive hypothesis testing.

    Markant, Douglas B; Gureckis, Todd M

    2014-02-01

    People can test hypotheses through either selection or reception. In a selection task, the learner actively chooses observations to test his or her beliefs, whereas in reception tasks data are passively encountered. People routinely use both forms of testing in everyday life, but the critical psychological differences between selection and reception learning remain poorly understood. One hypothesis is that selection learning improves learning performance by enhancing generic cognitive processes related to motivation, attention, and engagement. Alternatively, we suggest that differences between these 2 learning modes derives from a hypothesis-dependent sampling bias that is introduced when a person collects data to test his or her own individual hypothesis. Drawing on influential models of sequential hypothesis-testing behavior, we show that such a bias (a) can lead to the collection of data that facilitates learning compared with reception learning and (b) can be more effective than observing the selections of another person. We then report a novel experiment based on a popular category learning paradigm that compares reception and selection learning. We additionally compare selection learners to a set of "yoked" participants who viewed the exact same sequence of observations under reception conditions. The results revealed systematic differences in performance that depended on the learner's role in collecting information and the abstract structure of the problem.

  18. Coagulation Tests and Selected Biochemical Analytes in Dairy Cows with Hepatic Lipidosis

    S. Padilla-Arellanes; F. Constantino-Casas; L. Núnez-Ochoa; J. Doubek; C. Vega-Murguia; J. Bouda

    2007-01-01

    The aim of this study was to determine the values and changes in conventional and optimised clotting tests, as well as in selected biochemical analytes during hepatic lipidosis in postpartum dairy cows. Ten healthy and ten Holstein cows with hepatic lipidosis were selected based upon clinical history, clinical examination, liver biopsy, flotation test and histological analysis of hepatic tissue. Prothrombin time (PT) and partial thromboplastin time (PTT) were determined in non-diluted and dil...

  19. Brushless DC motor speed control strategy of simulation research

    Xiang Wen

    2017-01-01

    Full Text Available In view of the brushless DC motor speed regulation problem, an ideal control strategy is designed. Through the model and analysis of Brushless DC motor, the mathematical model of the brushless DC motor is obtained. By comparing three control strategies of PID control strategy, fuzzy control strategy and fuzzy PID control strategy, PID controller, fuzzy controller and fuzzy PID controller are designed respectively for simulation test. The simulation results show that the fuzzy PID controller has good control effect.

  20. Could situational judgement tests be used for selection into dental foundation training?

    Patterson, F; Ashworth, V; Mehra, S; Falcon, H

    2012-07-13

    To pilot and evaluate a machine-markable situational judgement test (SJT) designed to select candidates into UK dental foundation training. Single centre pilot study. UK postgraduate deanery in 2010. Seventy-four candidates attending interview for dental foundation training in Oxford and Wessex Deaneries volunteered to complete the situational judgement test. The situational judgement test was developed to assess relevant professional attributes for dentistry (for example, empathy and integrity) in a machine-markable format. Test content was developed by subject matter experts working with experienced psychometricians. Evaluation of psychometric properties of the pilot situational judgement test (for example, reliability, validity and fairness). Scores in the dental foundation training selection process (short-listing and interviews) were used to examine criterion-related validity. Candidates completed an evaluation questionnaire to examine candidate reactions and face validity of the new test. Forty-six candidates were female and 28 male; mean age was 23.5-years-old (range 22-32). Situational judgement test scores were normally distributed and the test showed good internal reliability when corrected for test length (α = 0.74). Situational judgement test scores positively correlated with the management, leadership and professionalism interview (N = 50; r = 0.43, p fair. This initial pilot study suggests that a situational judgement test is an appropriate and innovative method to measure professional attributes (eg empathy and integrity) for selection into foundation training. Further research will explore the long-term predictive validity of the situational judgement test once candidates have entered training.

  1. Comparative efficiency evaluation of buck and hybrid buck DC-DC converters for automotive applications

    Pelan, Ovidiu; Cornea, Octavian; Muntean, Nicolae

    2014-01-01

    This paper presents and discusses design considerations and efficiency investigation of a conventional step-down and a hybrid switched-capacitor DC-DC converter. Three MOSFETs with low on-resistance have been tested for each converter in order to find the most adequate switch for this application....... The experimental results and comparative efficiency graphs were obtained with a 1kW laboratory prototype dedicated for a 42/14V dual voltage automotive system....

  2. Noninvasive testing in coronary artery disease. Selection of procedures and interpretation of results

    Sox, H.C. Jr.

    1983-01-01

    In patients with acute chest pain, selection of diagnostic tests and admission to and discharge from the coronary care unit are critical decisions for which useful empirical guidelines are now available. In hospitalized patients, the serum level of the MB fraction of creatine kinase is particularly useful when the history strongly suggests infarction but the ECG is nondiagnostic. In patients with chronic chest pain, the gender of the patient and the character of the pain are the most important guides to selecting and interpreting exercise tests. In women and in men with nonanginal chest pain, the myocardial scintiscan is preferred to the exercise ECG because of its greater diagnostic accuracy. In men with atypical angina, the two tests are nearly equivalent, and the added cost of the scintiscan is a factor in test selection. Since nearly all men with typical angina have coronary artery disease, diagnostic tests are usually not needed

  3. Selecting the most appropriate inferential statistical test for your quantitative research study.

    Bettany-Saltikov, Josette; Whittaker, Victoria Jane

    2014-06-01

    To discuss the issues and processes relating to the selection of the most appropriate statistical test. A review of the basic research concepts together with a number of clinical scenarios is used to illustrate this. Quantitative nursing research generally features the use of empirical data which necessitates the selection of both descriptive and statistical tests. Different types of research questions can be answered by different types of research designs, which in turn need to be matched to a specific statistical test(s). Discursive paper. This paper discusses the issues relating to the selection of the most appropriate statistical test and makes some recommendations as to how these might be dealt with. When conducting empirical quantitative studies, a number of key issues need to be considered. Considerations for selecting the most appropriate statistical tests are discussed and flow charts provided to facilitate this process. When nursing clinicians and researchers conduct quantitative research studies, it is crucial that the most appropriate statistical test is selected to enable valid conclusions to be made. © 2013 John Wiley & Sons Ltd.

  4. Selection and application of C18200 chrome copper for the OHTE confinement test helical coil

    Puhn, F.A.; Graumann, D.W.

    1981-01-01

    The selection and qualification of copper for the OHTE confinement test helical coil (H-coil) was a crucial step in the success of this new experiment. Previous problems encountered at General Atomic Company with close tolerance machined parts made from high strength copper were identified. The design criteria included selecting a material with minimal warpage during machining, an electrical conductivity >80% IACS, and a yield strength of at least 241 Mpa (35 ksi). The investigation of candidate materials and testing samples led to selection of a material that fully met all requirements. The C18200 chrome copper forged plates were supplied by the Ampco Metal Division of Ampco-Pittsburgh Corporation

  5. Dual-task results and the lateralization of spatial orientation: artifact of test selection?

    Bowers, C A; Milham, L M; Price, C

    1998-01-01

    An investigation was conducted to identify the degree to which results regarding the lateralization of spatial orientation among men and women are artifacts of test selection. A dual-task design was used to study possible lateralization differences, providing baseline and dual-task measures of spatial-orientation performance, right- and left-hand tapping, and vocalization of "cat, dog, horse." The Guilford-Zimmerman Test (Guilford & Zimmerman, 1953), the Eliot-Price Test (Eliot & Price, 1976), and the Stumpf-Fay Cube Perspectives Test (Stumpf & Fay, 1983) were the three spatial-orientation tests used to investigate possible artifacts of test selection. Twenty-eight right-handed male and 39 right-handed female undergraduates completed random baseline and dual-task sessions. Analyses indicated no significant sex-related differences in spatial-orientation ability for all three tests. Furthermore, there was no evidence of differential lateralization of spatial orientation between the sexes.

  6. DISCRIMINATIVE ANALYSIS OF TESTS FOR EVALUATING SITUATIONMOTORIC ABILITIES BETWEEN TWO GROUPS OF BASKETBALL PLAYERS SELECTED BY THE TEST OF SOCIOMETRY

    Abdulla Elezi

    2011-09-01

    Full Text Available Determining differences between the two groups of basketball players selected with the modified sociometric test (Paranosić and Lazarević in some tests for assessing situation-motor skills, was the aim of this work. The test sample was consisted of 20 basketball players who had most positive points and 20 basketball players who had most negative points, in total- 40 players. T-test was applied to determine whether there are differences between the two groups of basketball players who had been elected with the help of the sociometric test. Analyses were made with the program SPSS 8.0. The discriminative analysis has determined that the differences in the arithmetic means between the groups of basketball players who had most positive points and the group of basketball players who had most negative points in some tests for assessing situation-motor abilities do not exist

  7. ITAR Free Commercial-of-the-Shelf DC/DC Converter

    Denzinger, Wolfgang; Hintze, Thomas

    2014-08-01

    A commercial-of-the-shelf (COTS) DC/DC converter for digital space equipment has been developed by ASP under ESA contract with special emphasis on low cost, no use of ITAR listed EEE parts like Mosfets, minimum number of rad-hard digital IC's and a design tolerance against single event effects by appropriate filtering. However, the intention to qualify this discrete converter design for a low cost FM series production was difficult due to the high up-sceening cost of EEE-parts with one lot guarantee and minimum-by. To overcome this problem, in a next step a redesign of the DC/DC converter was performed with all semiconductors like bipolar transistors, rectifiers and zener diodes packaged into hybrids. With this approach it was possible to buy a high number of less expensive wafers or dies from one lot, to perform a lot acceptance test and to integrate the dies into hybrid packages with further up- screening for FM use. The semiconductors have been packaged into three signal hybrids with 44 pins and one power hybrid with 24 pins for the dissipating transistors and rectifiers. The design of the hybrids is such, that all integrated semiconductors can be tested individually. The qualification of four EQM DC/DC converters with different combinations of output voltages has been successfully performed and two FM's have been manufactured and tested.

  8. A quick rhizobacterial selection tests for the remediation of copper contaminated soils.

    Braud, A M; Hubert, M; Gaudin, P; Lebeau, T

    2015-08-01

    The main objective of the study is to develop and improve quick bacterial tests to select the best candidates for the bioaugmentation of metal-contaminated soil, coupled with phytoextraction. Bacteria isolates (181) were selected from a collection originated from a Cu-contaminated sediment, on the basis of several miniaturized biochemical tests adapted to the copper contamination. Amongst them, we used a growth soil based-medium to select metal-tolerant bacteria, and their ability to grow and mobilize metals by mean of metabolites (siderophores, organic acids) was also assessed. The result of the bacterial selection tests showed differences in presence or absence of copper, especially for phosphate-solubilizing strains which ability decreased by 53% in the presence of copper hydroxide phosphate as compared to the standard tricalcium phosphate test. A promising Pseudomonas putida was selected from the collection. The study underlined the importance of choosing significant selection tests regarding the nature of the metal occurring in the soil to be cleaned-up to assess the real potential of each bacterial strain for subsequent soil bioaugmentation purposes. © 2015 The Society for Applied Microbiology.

  9. Optimization of the Dutch Matrix Test by Random Selection of Sentences From a Preselected Subset

    Rolph Houben

    2015-04-01

    Full Text Available Matrix tests are available for speech recognition testing in many languages. For an accurate measurement, a steep psychometric function of the speech materials is required. For existing tests, it would be beneficial if it were possible to further optimize the available materials by increasing the function’s steepness. The objective is to show if the steepness of the psychometric function of an existing matrix test can be increased by selecting a homogeneous subset of recordings with the steepest sentence-based psychometric functions. We took data from a previous multicenter evaluation of the Dutch matrix test (45 normal-hearing listeners. Based on half of the data set, first the sentences (140 out of 311 with a similar speech reception threshold and with the steepest psychometric function (≥9.7%/dB were selected. Subsequently, the steepness of the psychometric function for this selection was calculated from the remaining (unused second half of the data set. The calculation showed that the slope increased from 10.2%/dB to 13.7%/dB. The resulting subset did not allow the construction of enough balanced test lists. Therefore, the measurement procedure was changed to randomly select the sentences during testing. Random selection may interfere with a representative occurrence of phonemes. However, in our material, the median phonemic occurrence remained close to that of the original test. This finding indicates that phonemic occurrence is not a critical factor. The work highlights the possibility that existing speech tests might be improved by selecting sentences with a steep psychometric function.

  10. Optimizing the Use of Response Times for Item Selection in Computerized Adaptive Testing

    Choe, Edison M.; Kern, Justin L.; Chang, Hua-Hua

    2018-01-01

    Despite common operationalization, measurement efficiency of computerized adaptive testing should not only be assessed in terms of the number of items administered but also the time it takes to complete the test. To this end, a recent study introduced a novel item selection criterion that maximizes Fisher information per unit of expected response…

  11. Assessment of Selective Attention with CSCWT (Computerized Stroop Color-Word Test) among Children and Adults

    Afsaneh, Zarghi; Alireza, Zali; Mehdi, Tehranidost; Farzad, Ashrafi; Reza, Zarindast Mohammad; Mehdi, Moazzezi; Mojtaba, Khodadadi Seyed

    2012-01-01

    The SCWT (Stroop Color-Word Test) is a quick and frequently used measure for assessing selective attention and cognitive flexibility. This study determines age, sex and education level influence on attention and cognitive flexibility by CSCWT (Computerized Stroop Color-Word Test) among healthy Iranian children and adults. There were 78 healthy…

  12. Testing the normality assumption in the sample selection model with an application to travel demand

    van der Klaauw, B.; Koning, R.H.

    2003-01-01

    In this article we introduce a test for the normality assumption in the sample selection model. The test is based on a flexible parametric specification of the density function of the error terms in the model. This specification follows a Hermite series with bivariate normality as a special case.

  13. Testing the normality assumption in the sample selection model with an application to travel demand

    van der Klauw, B.; Koning, R.H.

    In this article we introduce a test for the normality assumption in the sample selection model. The test is based on a flexible parametric specification of the density function of the error terms in the model. This specification follows a Hermite series with bivariate normality as a special case.

  14. Tests of Selection in Pooled Case-Control Data: An Empirical Study

    Nitin eUdpa

    2011-11-01

    Full Text Available For smaller organisms with faster breeding cycles, artificial selection can be used to create sub-populations with different phenotypic traits. Genetic tests can be employed to identify the causal markers for the phenotypes, as a precursor to engineering strains with a combination of traits. Traditional approaches involve analyzing crosses of inbred strains to test for co-segregation with genetic markers. Here we take advantage of cheaper next generation sequencing techniques to identifygenetic signatures of adaptation to the selection constraints. Obtaining individual sequencing data is often unrealistic due to cost and sample issues, so we focus on pooled genomic data.In this paper, we explore a series of statistical tests for selection using pooled case (under selection and control populations. Extensive simulations are used to show that these approaches work well for a wide range of population divergence times and strong selective pressures. We show that pooling does not have a significant impact on statistical power. The tests are also robust to reasonable variations in several different parameters, including window size, base-calling error rate, and sequencing coverage. We then demonstrate the viability (and the challenges of one of these methods in two independent Drosophila populations (Drosophila melanogaster bred under selectionfor hypoxia and accelerated development, respectively. Testing for extreme hypoxia tolerance showed clear signals of selection, pointing to loci that are important for hypoxia adaptation.Overall, we outline a strategy for finding regions under selection using pooled sequences, then devise optimal tests for that strategy. The approaches show promise for detecting selection, even several generations after fixation of the beneficial allele has occurred.

  15. Artificial neural network control of sab dc/dc converter

    Mahar, M.A.; Abro, M.R.; Larik, A.S.

    2009-01-01

    The latest development of power semiconductor devices enable the modern power electronic converters to withstand high voltage and high power applications. Power electronic converters are mostly periodic variable structure systems due to their switched operations. The main drawback of these converters is the generation of oscillations which are developed during the operation of the converters under nonlinear situations. To handle these nonlinearities, various researchers have proposed different control techniques. Power electronic designers are devoting in the further development of converter topologies and their control techniques. SAB (Single Active Bridge) DC/DC converter is a new topology recently introduced by Demetriades. This topology is used in high voltage and high power applications. Because of its smart features, SAB converter has recently drawn attention of many researchers. However, during the operation of SAB converter severe oscillations are generated. In this research work, a novel NNC (Neural Network Controller) model is developed for SAB converter to minimize oscillations generated during its operation. NNC is believed to be an advanced nonlinear and robust controller which has the ability to map the nonlinear behaviour in a negligible response time. The performance of SAB converter with NNC is tested under dynamic region by considering the reference voltage variation and duty ratio variation. The SAB converter is implemented and simulated in MATLAB/Simulink. The simulated results are presented. (author)

  16. A Comparison of Multidimensional Item Selection Methods in Simple and Complex Test Designs

    Eren Halil ÖZBERK

    2017-03-01

    Full Text Available In contrast with the previous studies, this study employed various test designs (simple and complex which allow the evaluation of the overall ability score estimations across multiple real test conditions. In this study, four factors were manipulated, namely the test design, number of items per dimension, correlation between dimensions and item selection methods. Using the generated item and ability parameters, dichotomous item responses were generated in by using M3PL compensatory multidimensional IRT model with specified correlations. MCAT composite ability score accuracy was evaluated using absolute bias (ABSBIAS, correlation and the root mean square error (RMSE between true and estimated ability scores. The results suggest that the multidimensional test structure, number of item per dimension and correlation between dimensions had significant effect on item selection methods for the overall score estimations. For simple structure test design it was found that V1 item selection has the lowest absolute bias estimations for both long and short tests while estimating overall scores. As the model gets complex KL item selection method performed better than other two item selection method.

  17. TOPOLOGICAL REVIEW AND ANALYSIS OF DC-DC BOOST CONVERTERS

    V. INDRA GANDHI

    2017-06-01

    Full Text Available DC voltage boost up is essential in numerous applications; especially considering Photovoltaic (PV based renewable power generation system. The conventional DC-DC boost converter is the most admired configuration for this scheme, even if the converter efficiency is restricted at duty cycle near to maximum value. In order to find solution to the problem and improve its conversion capability, many converter configurations have been implemented so far. With this circumstance, this research work proposes to give overview of a few most imperative research works related to DC-DC boost converters. Some configurations are covered and classified basically based on the application. The major benefits and disadvantages related to the available techniques are also briefly conveyed. At last, a proper evaluation is recognized among the important types of DC-DC boost converters in terms of efficiency, number of components, and stability.

  18. Test methods for selection of materials of construction for high-level radioactive waste vitrification. Revision

    Bickford, D.F.; Corbett, R.A.; Morrison, W.S.

    1986-01-01

    Candidate materials of construction were evaluated for a facility at the Department of Energy's Savannah River Plant to vitrify high-level radioactive waste. Limited operating experience was available under the corrosive conditions of the complex vitrification process. The objective of the testing program was to provide a high degree of assurance that equipment will meet or exceed design lifetimes. To meet this objective in reasonable time and minimum cost, a program was designed consisting of a combination of coupon immersion and electrochemical laboratory tests and pilot-scale tests. Stainless steels and nickel-based alloys were tested. Alloys that were most resistant to general and local attack contained nickel, molybdenum (>9%), and chromium (where Cr + Mo > 30%). Alloy C-276 was selected as the reference material for process equipment. Stellite 6 was selected for abrasive service in the presence of formic acid. Alloy 690 and ALLCORR were selected for specific applications

  19. An Integrated Multifunctional Bidirectional AC/DC and DC/DC Converter for Electric Vehicles Applications

    Liwen Pan; Chengning Zhang

    2016-01-01

    This paper presents an on-board vehicular battery charger that integrates bidirectional AC/DC converter and DC/DC converter to achieve high power density for application in electric vehicles (EVs). The integrated charger is able to transfer electrical energy between the battery pack and the electric traction system and to function as an AC/DC battery charger. The integrated charger topology is presented and the design of passive components is discussed. The control schemes are developed for m...

  20. A Virtual Inertia Control Strategy for DC Microgrids Analogized with Virtual Synchronous Machines

    Wu, Wenhua; Chen, Yandong; Luo, An

    2017-01-01

    In a DC microgrid (DC-MG), the dc bus voltage is vulnerable to power fluctuation derived from the intermittent distributed energy or local loads variation. In this paper, a virtual inertia control strategy for DC-MG through bidirectional grid-connected converters (BGCs) analogized with virtual...... synchronous machine (VSM) is proposed to enhance the inertia of the DC-MG, and to restrain the dc bus voltage fluctuation. The small-signal model of the BGC system is established, and the small-signal transfer function between the dc bus voltage and the dc output current of the BGC is deduced. The dynamic...... for the BGC is introduced to smooth the dynamic response of the dc bus voltage. By analyzing the control system stability, the appropriate virtual inertia control parameters are selected. Finally, simulations and experiments verified the validity of the proposed control strategy....

  1. Microstructure and Mechanical Behavior of Deep Drawing DC04 Steel at Different Length Scales

    Schreijäg, Simone

    2013-01-01

    The deformation behavior of steels is strongly influenced by their microstructure which is a result of the alloying elements and thermal treatments. In this work, the microstructure and the deformation behavior of a non-alloyed deep drawing DC04 steel was investigated. The microstructure was analyzed during heat treatment by EBSD, then microcompression experiments were performed on selected microstructural units and then bulk steel samples were mechanically tested by tensile experiments.

  2. Stability of selected volatile contact allergens in different patch test chambers under different storage conditions

    Mose, Kristian Fredløv; Andersen, Klaus Ejner; Christensen, Lars Porskjaer

    2012-01-01

    Background. Patch test preparations of volatile substances may evaporate during storage, thereby giving rise to reduced patch test concentrations. Objectives. To investigate the stability of selected acrylates/methacrylates and fragrance allergens in three different test chambers under different...... both storage conditions, whereas MMA and 2-HPA required cool storage for maintenance of the limit. Conclusion. The Van der Bend® transport container was the best device for storage of samples of volatile contact allergens....

  3. Entropy Based Test Point Evaluation and Selection Method for Analog Circuit Fault Diagnosis

    Yuan Gao

    2014-01-01

    Full Text Available By simplifying tolerance problem and treating faulty voltages on different test points as independent variables, integer-coded table technique is proposed to simplify the test point selection process. Usually, simplifying tolerance problem may induce a wrong solution while the independence assumption will result in over conservative result. To address these problems, the tolerance problem is thoroughly considered in this paper, and dependency relationship between different test points is considered at the same time. A heuristic graph search method is proposed to facilitate the test point selection process. First, the information theoretic concept of entropy is used to evaluate the optimality of test point. The entropy is calculated by using the ambiguous sets and faulty voltage distribution, determined by component tolerance. Second, the selected optimal test point is used to expand current graph node by using dependence relationship between the test point and graph node. Simulated results indicate that the proposed method more accurately finds the optimal set of test points than other methods; therefore, it is a good solution to minimize the size of the test point set. To simplify and clarify the proposed method, only catastrophic and some specific parametric faults are discussed in this paper.

  4. Congruence analysis of geodetic networks - hypothesis tests versus model selection by information criteria

    Lehmann, Rüdiger; Lösler, Michael

    2017-12-01

    Geodetic deformation analysis can be interpreted as a model selection problem. The null model indicates that no deformation has occurred. It is opposed to a number of alternative models, which stipulate different deformation patterns. A common way to select the right model is the usage of a statistical hypothesis test. However, since we have to test a series of deformation patterns, this must be a multiple test. As an alternative solution for the test problem, we propose the p-value approach. Another approach arises from information theory. Here, the Akaike information criterion (AIC) or some alternative is used to select an appropriate model for a given set of observations. Both approaches are discussed and applied to two test scenarios: A synthetic levelling network and the Delft test data set. It is demonstrated that they work but behave differently, sometimes even producing different results. Hypothesis tests are well-established in geodesy, but may suffer from an unfavourable choice of the decision error rates. The multiple test also suffers from statistical dependencies between the test statistics, which are neglected. Both problems are overcome by applying information criterions like AIC.

  5. Transition towards DC micro grids: From an AC to a hybrid AC and DC energy infrastructure

    Evi Ploumpidou

    2017-12-01

    Full Text Available Our electricity is predominantly powered by alternating current (AC, ever since the War of Currents ended in the favor of Nicola Tesla at the end of the 19th century. However, lots of the appliances we use, such as electronics and lights with light-emitting diode (LED technology, work internally on direct current (DC and it is projected that the number of these appliances will increase in the near future. Another contributor to the increase in DC consumption is the ongoing electrification of mobility (Electric Vehicles (EVs. At the same time, photovoltaics (PV generate DC voltages, while the most common storage technologies also use DC. In order to integrate all these appliances and technologies to the existing AC grid, there is a need for converters which introduce power losses. By distributing DC power to DC devices instead of converting it to AC first, it is possible to avoid substantial energy losses that occur every time electricity is converted. This situation initiated the concept for the implementation of the DC-Flexhouse project. A prototype DC installation will be developed and tested in one of the buildings of the developing living lab area called the District of Tomorrow (De Wijk van Morgen which is located in Heerlen, the Netherlands. A neighborhood cooperative (Vrieheide cooperatie is also part of the consortium in order to address the aspect of social acceptance. Although DC seems to be a promising solution for a more sustainable energy system, the business case is still debatable due to both technology- and market-related challenges. The current energy infrastructure is predominantly based on AC, manufacturers produce devices based on AC standards and people are using many AC products across a long life span. This Smart Energy Buildings & Cities (SEB&C PDEng project is a contribution to the DC-Flexhouse project. The aim is to analyze the challenges in the transition to DC micro grids, assess the market potential of DC

  6. Double-barrier junction based dc SQUID

    Bartolomé, M.E.; Brinkman, Alexander; Flokstra, Jakob; Golubov, Alexandre Avraamovitch; Rogalla, Horst

    2000-01-01

    dc SQUIDs based on double-barrier Nb/Al/AlOx/Al/AlOx/Al/Nb junctions (DBSQs) have been fabricated and tested for the first time. The current–voltage curves have been measured at temperatures down to 1.4 K. The critical current, Ic, dependence on the temperature T is partially described by the

  7. Implementation of hierarchical control in DC microgrids

    Jin, Chi; Wang, Peng; Xiao, Jianfang

    2014-01-01

    of Technology, Singapore. The coordination control among multiple dc sources and energy storages is implemented using a novel hierarchical control technique. The bus voltage essentially acts as an indicator of supply-demand balance. A wireless control is implemented for the reliable operation of the grid....... A reasonable compromise between the maximum power harvest and effective battery management is further enhanced using the coordination control based on a central energy management system. The feasibility and effectiveness of the proposed control strategies have been tested by a dc microgrid in WERL....

  8. Color test for selective detection of secondary amines on resin and in solution.

    Boas, Ulrik; Mirsharghi, Sahar

    2014-11-21

    Resins for solid-phase synthesis give orange to red-brown resin beads selectively when secondary amines are present on the resin when treated with a solution of acetaldehyde and an Fmoc-amino acid in NMP. The method shows good specificity and gives colorless beads when exposed to a variety of other functional groups. Furthermore, the acetaldehyde/Fmoc amino acid method can be used as a selective colorimetric test for secondary amines in solution.

  9. Auxiliary resonant DC tank converter

    Peng, Fang Z.

    2000-01-01

    An auxiliary resonant dc tank (ARDCT) converter is provided for achieving soft-switching in a power converter. An ARDCT circuit is coupled directly across a dc bus to the inverter to generate a resonant dc bus voltage, including upper and lower resonant capacitors connected in series as a resonant leg, first and second dc tank capacitors connected in series as a tank leg, and an auxiliary resonant circuit comprising a series combination of a resonant inductor and a pair of auxiliary switching devices. The ARDCT circuit further includes first clamping means for holding the resonant dc bus voltage to the dc tank voltage of the tank leg, and second clamping means for clamping the resonant dc bus voltage to zero during a resonant period. The ARDCT circuit resonantly brings the dc bus voltage to zero in order to provide a zero-voltage switching opportunity for the inverter, then quickly rebounds the dc bus voltage back to the dc tank voltage after the inverter changes state. The auxiliary switching devices are turned on and off under zero-current conditions. The ARDCT circuit only absorbs ripples of the inverter dc bus current, thus having less current stress. In addition, since the ARDCT circuit is coupled in parallel with the dc power supply and the inverter for merely assisting soft-switching of the inverter without participating in real dc power transmission and power conversion, malfunction and failure of the tank circuit will not affect the functional operation of the inverter; thus a highly reliable converter system is expected.

  10. PENGGUNAAN FUZZY LOGIC UNTUK KONTROL PARALLEL CONVERTER DC-DC

    Bambang Prio Hartono

    2012-09-01

    Full Text Available Abstract: Using system fuzzy logic as control  technology have been used on low load dc-dc converter with combined parallel compiled  dc-dc converter can  obtain big load.   With existence of differrence of component parameter and each parallel compiled converter can obtained different current  and voltage output.  Function of controller  for to do adjustment, so that current which is applied  to  load by each converter  can be obtained  difference error as small as possible or same. The object of research is developing design of large signal dc-dc converter which is  combined with using  FLC so that  obtain  better performance.  To get better performance have been made plant model and simulation with CDE method.  The more systematic  system and design is needed to overcome bigger load  on dc-dc converter, so that parallel  compiled current master slave control system on dc-dc converter with using fuzzy logic  controller is used. Result of  research showed that error or difference of  current  which is applied to load can handled by fuzzy logic  controller.  Technic of current and voltage controller co to do adjustment current and voltage distribution  equally to load.  Distribution of iL1,iL2 and  output voltage Vo on dc-dc  converter with load 2,25 until  7,875 and voltage  100  until 120 volt,  load current beetwen  12 until 48, % relatif  error  Vo  0,4% until  0,9%.

  11. Sliding-mode control of single input multiple output DC-DC converter

    Zhang, Libo; Sun, Yihan; Luo, Tiejian; Wan, Qiyang

    2016-10-01

    Various voltage levels are required in the vehicle mounted power system. A conventional solution is to utilize an independent multiple output DC-DC converter whose cost is high and control scheme is complicated. In this paper, we design a novel SIMO DC-DC converter with sliding mode controller. The proposed converter can boost the voltage of a low-voltage input power source to a controllable high-voltage DC bus and middle-voltage output terminals, which endow the converter with characteristics of simple structure, low cost, and convenient control. In addition, the sliding mode control (SMC) technique applied in our converter can enhance the performances of a certain SIMO DC-DC converter topology. The high-voltage DC bus can be regarded as the main power source to the high-voltage facility of the vehicle mounted power system, and the middle-voltage output terminals can supply power to the low-voltage equipment on an automobile. In the respect of control algorithm, it is the first time to propose the SMC-PID (Proportion Integration Differentiation) control algorithm, in which the SMC algorithm is utilized and the PID control is attended to the conventional SMC algorithm. The PID control increases the dynamic ability of the SMC algorithm by establishing the corresponding SMC surface and introducing the attached integral of voltage error, which endow the sliding-control system with excellent dynamic performance. At last, we established the MATLAB/SIMULINK simulation model, tested performance of the system, and built the hardware prototype based on Digital Signal Processor (DSP). Results show that the sliding mode control is able to track a required trajectory, which has robustness against the uncertainties and disturbances.

  12. Step-Up DC-DC Power Converter

    2015-01-01

    The present invention relates to a step-up DC-DC power converter which comprises a primary side circuit and a secondary side circuit coupled through a galvanic isolation barrier. The primary side circuit comprises a positive and a negative input terminal for receipt of an input voltage and an input...... being charged from the input voltage and discharged to the output capacitor through the galvanic isolation barrier in accordance with a switch control signal to produce the converter output voltage. The step-up DC-DC power converter comprises an electrical short-circuit connection across the galvanic...

  13. Superconducting dc fault current limiter

    Cointe, Y.

    2007-12-01

    Within the framework of the electric power market liberalization, DC networks have many interests compared to alternative ones, but their protections need to use new systems. Superconducting fault current limiters enable by an overstepping of the critical current to limit the fault current to a preset value, lower than the theoretical short-circuit current. For these applications, coated conductors offer excellent opportunities. We worked on the implementation of these materials and built a test bench. We carried out limiting experiments to estimate the quench homogeneity at various short-circuit parameters. An important point is the temperature measurement by deposited sensors on the ribbon, results are in good correlation with the theoretical models. Improved quench behaviours for temperatures close to the critical temperature have been confirmed. Our results enable to better understand the limitation mechanisms of coated conductors. (author)

  14. Nuclear waste transportation package testing: A review of selected programs in the United States and abroad

    Snedeker, D.F.

    1990-12-01

    This report provides an overview of some recent nuclear waste transportation package development programs. This information is intended to aid the State of Nevada in its review of US Department of Energy (DOE) nuclear waste transportation programs. This report addresses cask testing programs in the United Kingdom and selected 1/4 and full scale testing in the US. Facilities that can provide cask testing services, both in the US and to a limited extent abroad, are identified. The costs for different type test programs are identified as a means to estimate costs for future test programs. Not addressed is the public impact such testing might have in providing an increased sense of safety or confidence. The British test program was apparently quite successful in demonstrating safety to the public at the time. There is no US test effort that is similar in scope for direct comparison. Also addressed are lessons learned from testing programs and areas that may merit possible future integrated examination. Areas that may require further examination are both technical and institutional. This report provides information which, when combined with other sources of information will enable the State of Nevada to assess the following areas: feasibility of full scale testing; costs of full scale tests; potential benefits of testing; limits that full scale testing impose; and disadvantages of emphasis on testing vs analytical solutions. This assessment will then allow the state to comment on DOE Office of Civilian Radioactive Waste Management (OCRWM) plans for the development and licensing of new shipping cask designs. These plans currently expect contractors to perform engineering testing for materials development, quarter scale model testing to validate analytical assessments and full scale prototype testing of operational features. DOE currently plans no full scale or extra-regulatory destructive testing to aid in cask licensing. 1 tab

  15. Experience from design, prototyping and production of a DC-DC conversion powering scheme for the CMS Phase-1 Pixel Upgrade

    Feld, L.; Karpinski, W.; Klein, K.; Lipinski, M.; Preuten, M.; Rauch, M.; Schmitz, S.; Wlochal, M.

    2016-01-01

    The CMS collaboration has adopted a DC-DC conversion powering scheme for the Phase-1 Upgrade of its pixel detector. DC-DC buck converters with a conversion ratio of around 3 are installed on the support structures, outside of the sensitive tracking region, requiring a re-design of the low and high voltage distribution to the pixel modules. After several years of R and D, the project has entered the production phase. A total of 1800 DC-DC converters are being produced, and rigorous quality assurance and control is being employed during the production process. The testing program is outlined, results from mass production are presented and issues that have been encountered are described. In addition, two system level challenges, namely the choice of output voltage in the presence of large, load-dependent voltage drops, and the thermal management required to remove the heat load caused by the DC-DC converters, are discussed

  16. Selection of areas for testing in the Eleana formation: Paleozoic geology of western Yucca Flat

    Sweeney, J J

    1984-07-01

    The Paleozoic geology of NTS is reviewed to select an area for underground nuclear testing in shale. Constraints on possible areas, dictated by test program requirements and economics, are areas with topographic slope less than 5/sup 0/, depths to working point less than 3000 ft., and working points above the water table. The rock formation selected is Unit J (argillite) of the Mississippian age Eleana Formation. Within NTS, Western Yucca Flat is selected as the best area to meet the requirements. Details of the Paleozoic structure of western Yucca Flat are presented. The interpretation is based on published maps, cross-sections, and reports as well as borehole, refraction seismic, and gravity data. In terms of subsurface structure and areas where Eleana Formation Unit J occurs at depths between 500 ft to 3000 ft, four possible testing areas are identified. The areas are designated here as A, B, C and the Gravity High. Available data on the water table (static water level) is reviewed for western Yucca Flat area. Depth to the water table increases from 500 to 600 ft in Area A to 1500 ft or more in the Gravity High area. Review of the water table data rules out area A and B for testing in argillite above the water table. Area C is relatively unexplored and water conditions are unknown there. Thus, the Gravity High is selected as the most promising area for selecting testing sites. There is a dolomite thrust sheet of unknown thickness overlying the argillite in the Gravity High area. An exploration program is proposed to better characterize this structure. Finally, recommendations are made for procedures to follow for eventual site characterization of a testing site in argillite. 22 references, 12 figures, 1 table.

  17. Site selection report basalt waste isolation program near-surface test facility

    Sharpe, S.D.

    1978-01-01

    A site selection committee was established to review the information gathered on potential sites and to select a site for the Near-Surface Test Facility Phase I. A decision was made to use a site on the north face of Gable Mountain located on the Hanford Site. This site provided convenient access to the Pomona Basalt Flow. This flow was selected for use at this site because it exhibited the characteristics established in the primary criteria. These criteria were: the flows thickness; its dryness; its nearness to the surface; and, its similarities to basalt units which are candidates for the repository. After the selection of the Near-Surface Test Facility Phase I Site, the need arose for an additional facility to demonstrate safe handling, storage techniques, and the physical effects of radioactive materials on an in situ basalt formation. The committee reviewed the sites selected for Phase I and chose the same site for locating Phase II of the Near-Surface Test Facility

  18. Testing whether Metazoan Tyrosine Loss Was Driven by Selection against Promiscuous Phosphorylation

    Pandya, Siddharth; Struck, Travis J.; Mannakee, Brian K.; Paniscus, Mary; Gutenkunst, Ryan N.

    2015-01-01

    Protein tyrosine phosphorylation is a key regulatory modification in metazoans, and the corresponding kinase enzymes have diversified dramatically. This diversification is correlated with a genome-wide reduction in protein tyrosine content, and it was recently suggested that this reduction was driven by selection to avoid promiscuous phosphorylation that might be deleterious. We tested three predictions of this intriguing hypothesis. 1) Selection should be stronger on residues that are more likely to be phosphorylated due to local solvent accessibility or structural disorder. 2) Selection should be stronger on proteins that are more likely to be promiscuously phosphorylated because they are abundant. We tested these predictions by comparing distributions of tyrosine within and among human and yeast orthologous proteins. 3) Selection should be stronger against mutations that create tyrosine versus remove tyrosine. We tested this prediction using human population genomic variation data. We found that all three predicted effects are modest for tyrosine when compared with the other amino acids, suggesting that selection against deleterious phosphorylation was not dominant in driving metazoan tyrosine loss. PMID:25312910

  19. DC Distribution Systems and Microgrids

    Dragicevic, Tomislav; Anvari-Moghaddam, Amjad; Quintero, Juan Carlos Vasquez

    2017-01-01

    summarized. Due to its attractive characteristics in terms of compliance with modern generation, storage and electronic load technologies, high reliability and current carrying capacity, as well as simple control, DC systems are already an indispensable part of power systems. Moreover, the existing......A qualitative overview of different hardware topologies and control systems for DC MGs has been presented in this chapter. Some challenges and design considerations of DC protections systems have also been discussed. Finally, applications of DC MGs in emerging smart grid applications have been...... challenges such as protection issues will be effectively resolved in the near future due to fast progress of semiconductor technology which is a key enabler cheap and reliable future DC solid-state protection systems. Therefore, it is the view of the author that more and more DC systems will appear...

  20. DC-DC Converter Topology Assessment for Large Scale Distributed Photovoltaic Plant Architectures

    Agamy, Mohammed S; Harfman-Todorovic, Maja; Elasser, Ahmed; Sabate, Juan A; Steigerwald, Robert L; Jiang, Yan; Essakiappan, Somasundaram

    2011-07-01

    Distributed photovoltaic (PV) plant architectures are emerging as a replacement for the classical central inverter based systems. However, power converters of smaller ratings may have a negative impact on system efficiency, reliability and cost. Therefore, it is necessary to design converters with very high efficiency and simpler topologies in order not to offset the benefits gained by using distributed PV systems. In this paper an evaluation of the selection criteria for dc-dc converters for distributed PV systems is performed; this evaluation includes efficiency, simplicity of design, reliability and cost. Based on this evaluation, recommendations can be made as to which class of converters is best fit for this application.

  1. Battery designs the testing physical of skills for selecting talented taekwondo

    Mohammed Mustafa Bakr

    2016-07-01

    Full Text Available The aim of this study is to design a battery test physical of skill for the selection of talented young taekwondo Egyptian national project for may have a practical importance of overseeing the selection of young people as well as in the planning of the training process to reach high levels. Applied study on a sample of (750 Individual clubs and youth centers in 14 countries in the Arab Republic of Egypt, and the average age of (11.11 ± 1.06 years, height (143.50 ± 11,09 cm and weight (42.53 ±10,74kg. Tests were conducted in the period from 17/11/2012 to 29/12/2012. Physical tests following (Ability, Hinge flexibility basin, Agility, Kinetics speed in a level trunk, Kinetics speed in the level face, Endure Performance. Scientific transactions testing laboratories account sincerity and consistency of the tests used in the study. Where the value of the coefficient of sincerity d statistically at the level of the significance of 0.05 is a sign the two sides between the high level and the low level as the value of the coefficient of sincerity between (0.682, 0.932, which indicates that the tests measure what it was made. It was also correlation coefficient d statistically at the level of an indication (0.01 and (0.05 is a sign of the two parties, where the value of P < 0.05 in all tests as they ranged between (0.964-0.998, pointing to a flat these tests. The researcher used the descriptive survey method. Calculated using the weight of the medical balance and use a tape measure to the nearest (0.5 cm. The statistical analysis SPSS was used to apply formulas statistical by calculating: average, standard deviation, correlation, Factor analysis, Six Sigma Score, percentile scores. The results of the standard levels the battery test of physical skills extracted the selection of talented taekwondo sports in the factors of grace the second factor is the dynamic speed. The study concluded that this study concluded to a battery physical of skill tests for

  2. Empirical test of Capital Asset Pricing Model on Selected Banking Shares from Borsa Istanbul

    Fuzuli Aliyev

    2018-03-01

    Full Text Available In this paper we tested Capital Asset Pricing Model (shortly CAPM hereafter on the selected banking stocks of Borsa Istanbul. Here we tried to explain how to price financial assets based on their risks in the case of BIST-100 index. CAPM is an important model in the portfolio management theory used by economic agents for the selection of financial assets. We used 12 random banking stocks’ monthly return data for 2001–2010 periods. To test the validity of the CAPM, we first derived the regression equation for the risk-free interest rate and risk premium relationship using January 2001–December 2009 data. Then, estimated January–December 2010 returns with the equation. Comparing forecasted return with the actual return, we concluded that the CAPM is valid for the portfolio consisting of the 12 banks traded in the ISE, i.e. The model could predict the overall outcome of portfolio of selected banking shares

  3. Participation in prenatal screening tests and intentions concerning selective termination in Finnish maternity care

    Santalahti, P; Hemminki, E; Aro, A R

    1999-01-01

    AIMS: The study examined how prenatal screening tests are presented to women, factors associated with women's participation in screening, their experience of decision-making and intentions concerning pregnancy termination, and hospital data on rates of selective terminations. METHODS: Questionnai......AIMS: The study examined how prenatal screening tests are presented to women, factors associated with women's participation in screening, their experience of decision-making and intentions concerning pregnancy termination, and hospital data on rates of selective terminations. METHODS...... as a routine procedure. Most women (92%) underwent serum screening and most (86%) found the decision to participate or not easy. In almost every aspect of presentation and participation studied, serum and ultrasound screening differed from each other. 85% of respondents to ultrasound screening answered...... in screening and with intentions about selective termination, women's perceptions of lives of the disabled should receive more attention in future studies....

  4. On the effect of emotional states on operator thinking. [psychological test for operator selection

    Solodkova, A. V.

    1975-01-01

    A combination sonic and electrical skin stimuli stress test is reported that is suitable for the psychological selection of individuals to perform operator functions. The behavior of these people is characterized by a fighting spirit, increased work capacity, minimum expenditure of strength and insignificant fatigue.

  5. Temporal Lobe Epilepsy and the Selective Reminding Test: The Conventional 30-Minute Delay Suffices

    Bell, Brian D.; Fine, Jason; Dow, Christian; Seidenberg, Michael; Hermann, Bruce P.

    2005-01-01

    Conventional memory assessment may fail to identify memory dysfunction characterized by intact recall for a relatively brief period but rapid forgetting thereafter. This study assessed learning and retention after 30-min and 24-hr delays on auditory and visual selective reminding tests (SRTs) in right (n=20) and left (n=22) temporal lobe epilepsy…

  6. A Method for the Comparison of Item Selection Rules in Computerized Adaptive Testing

    Barrada, Juan Ramon; Olea, Julio; Ponsoda, Vicente; Abad, Francisco Jose

    2010-01-01

    In a typical study comparing the relative efficiency of two item selection rules in computerized adaptive testing, the common result is that they simultaneously differ in accuracy and security, making it difficult to reach a conclusion on which is the more appropriate rule. This study proposes a strategy to conduct a global comparison of two or…

  7. Testing for a genetic response to sexual selection in a wild Drosophila population.

    Gosden, T P; Thomson, J R; Blows, M W; Schaul, A; Chenoweth, S F

    2016-06-01

    In accordance with the consensus that sexual selection is responsible for the rapid evolution of display traits on macroevolutionary scales, microevolutionary studies suggest sexual selection is a widespread and often strong form of directional selection in nature. However, empirical evidence for the contemporary evolution of sexually selected traits via sexual rather than natural selection remains weak. In this study, we used a novel application of quantitative genetic breeding designs to test for a genetic response to sexual selection on eight chemical display traits from a field population of the fly, Drosophila serrata. Using our quantitative genetic approach, we were able to detect a genetically based difference in means between groups of males descended from fathers who had either successfully sired offspring or were randomly collected from the same wild population for one of these display traits, the diene (Z,Z)-5,9-C27 : 2 . Our experimental results, in combination with previous laboratory studies on this system, suggest that both natural and sexual selection may be influencing the evolutionary trajectories of these traits in nature, limiting the capacity for a contemporary evolutionary response. © 2016 European Society For Evolutionary Biology. Journal of Evolutionary Biology © 2016 European Society For Evolutionary Biology.

  8. A GMM-Based Test for Normal Disturbances of the Heckman Sample Selection Model

    Michael Pfaffermayr

    2014-10-01

    Full Text Available The Heckman sample selection model relies on the assumption of normal and homoskedastic disturbances. However, before considering more general, alternative semiparametric models that do not need the normality assumption, it seems useful to test this assumption. Following Meijer and Wansbeek (2007, the present contribution derives a GMM-based pseudo-score LM test on whether the third and fourth moments of the disturbances of the outcome equation of the Heckman model conform to those implied by the truncated normal distribution. The test is easy to calculate and in Monte Carlo simulations it shows good performance for sample sizes of 1000 or larger.

  9. BRBN-T validation: adaptation of the Selective Reminding Test and Word List Generation

    Mariana Rigueiro Neves

    2015-10-01

    Full Text Available Objective This study aims to present the Selective Reminding Test(SRT and Word List Generation (WLG adaptation to the Portuguese population, within the validation of the Brief Repeatable Battery of Neuropsychological Tests (BRBN-Tfor multiple sclerosis (MS patients.Method 66 healthy participants (54.5% female recruited from the community volunteered to participate in this study.Results A combination of procedures from Classical Test Theory (CTT and Item Response Theory (ITR were applied to item analysis and selection. For each SRT list, 12 words were selected and 3 letters were chosen for WLG to constitute the final versions of these tests for the Portuguese population.Conclusion The combination of CTT and ITR maximized the decision making process in the adaptation of the SRT and WLG to a different culture and language (Portuguese. The relevance of this study lies on the production of reliable standardized neuropsychological tests, so that they can be used to facilitate a more rigorous monitoring of the evolution of MS, as well as any therapeutic effects and cognitive rehabilitation.

  10. A Method to Select Software Test Cases in Consideration of Past Input Sequence

    Kim, Hee Eun; Kim, Bo Gyung; Kang, Hyun Gook

    2015-01-01

    In the Korea Nuclear I and C Systems (KNICS) project, the software for the fully-digitalized reactor protection system (RPS) was developed under a strict procedure. Even though the behavior of the software is deterministic, the randomness of input sequence produces probabilistic behavior of software. A software failure occurs when some inputs to the software occur and interact with the internal state of the digital system to trigger a fault that was introduced into the software during the software lifecycle. In this paper, the method to select test set for software failure probability estimation is suggested. This test set reflects past input sequence of software, which covers all possible cases. In this study, the method to select test cases for software failure probability quantification was suggested. To obtain profile of paired state variables, relationships of the variables need to be considered. The effect of input from human operator also have to be considered. As an example, test set of PZR-PR-Lo-Trip logic was examined. This method provides framework for selecting test cases of safety-critical software

  11. Very High Frequency Half Bridge DC/DC Converter

    Madsen, Mickey Pierre; Knott, Arnold; Andersen, Michael A. E.

    2014-01-01

    This paper presents the first, off chip, class DE (resonant half bridge) converter working in the Very High Frequency (VHF) range. The benefits of using half bridge circuits both in the inverter and rectifier part of a VHF resonant dc/dc converter are analyzed and design equations for all...

  12. SCM Handbooks for dc-to-dc Converters

    Lee, F.; Mohmoud, M.; Yu, Y.

    1984-01-01

    Two documents aid in design of control modules for dc-to-dc converters. Features of SCM include: Adaptive stability, power component stress limiting, implementation of various control laws, unified design approach. Analysis and quidelines contained in handbooks enable engineer to design SCM circuit and confidently predict resulting overall performance.

  13. Sheppard-Taylor Isolated High Boost DC-DC Converter

    Chub, Andrii; Siwakoti, Yam Prasad; Vinnikov, Dmitri

    2017-01-01

    This paper presents a new galvanically isolated step-up dc-dc converter intended for low-power but high step-up applications. The proposed converter is capable of regulating output voltage within a wide range of the input voltage or load variations. In contrast to competitors, the converter can...

  14. Dc-To-Dc Converter Uses Reverse Conduction Of MOSFET's

    Gruber, Robert P.; Gott, Robert W.

    1991-01-01

    In modified high-power, phase-controlled, full-bridge, pulse-width-modulated dc-to-dc converters, switching devices power metal oxide/semiconductor field-effect transistors (MOSFET's). Decreases dissipation of power during switching by eliminating approximately 0.7-V forward voltage drop in anti-parallel diodes. Energy-conversion efficiency increased.

  15. A Current-Fed Isolated Bidirectional DC-DC Converter

    Sun, Xiaofeng; Wu, Xiaoying; Shen, Yanfeng

    2017-01-01

    This paper proposes a current-fed isolated bidirectional DC-DC converter (CF-IBDC) which has the advantages of wide input voltage range, low input current ripple, low conduction losses, and soft switching over the full operating range. Compared with conventional CF-IBDCs, the voltage spikes...

  16. Power flow analysis for DC voltage droop controlled DC microgrids

    Li, Chendan; Chaudhary, Sanjay; Dragicevic, Tomislav

    2014-01-01

    This paper proposes a new algorithm for power flow analysis in droop controlled DC microgrids. By considering the droop control in the power flow analysis for the DC microgrid, when compared with traditional methods, more accurate analysis results can be obtained. The algorithm verification is ca...

  17. Inter-tester reliability of selected clinical tests for long-lasting temporomandibular disorders.

    Julsvoll, Elisabeth Heggem; Vøllestad, Nina Køpke; Opseth, Gro; Robinson, Hilde Stendal

    2017-09-01

    Clinical tests used to examine patients with temporomandibular disorders vary in methodological quality, and some are not tested for reliability. The purpose of this cross-sectional study was to evaluate inter-tester reliability of clinical tests and a cluster of tests used to examine patients with long-lasting temporomandibular disorders. Forty patients with pain in the temporomandibular area treated by health-professionals were included. They were between 18-70 years, had 65 symptomatic (33 right/32 left) and 15 asymptomatic joints. Two manual therapists examined all participants with selected tests. Percentage agreement and the kappa coefficient ( k ) with 95% confidence interval (CI) were used to evaluate the tests with categorical outcomes. For tests with continuous outcomes, the relative inter-tester reliability was assessed by the intraclass-correlation-coefficient (ICC 3,1 , 95% CI) and the absolute reliability was calculated by the smallest detectable change (SDC). The best reliability among single tests was found for the dental stick test, the joint-sound test ( k  = 0.80-1.0) and range of mouth-opening (ICC 3,1 (95% CI) = 0.97 (0.95-0.98) and SDC = 4 mm). The reliability of cluster of tests was excellent with both four and five positive tests out of seven. The reliability was good to excellent for the clinical tests and the cluster of tests when performed by experienced therapists. The tests are feasible for use in the clinical setting. They require no advanced equipment and are easy to perform.

  18. Testing the efficiency of rover science protocols for robotic sample selection: A GeoHeuristic Operational Strategies Test

    Yingst, R. A.; Bartley, J. K.; Chidsey, T. C.; Cohen, B. A.; Gilleaudeau, G. J.; Hynek, B. M.; Kah, L. C.; Minitti, M. E.; Williams, R. M. E.; Black, S.; Gemperline, J.; Schaufler, R.; Thomas, R. J.

    2018-05-01

    The GHOST field tests are designed to isolate and test science-driven rover operations protocols, to determine best practices. During a recent field test at a potential Mars 2020 landing site analog, we tested two Mars Science Laboratory data-acquisition and decision-making methods to assess resulting science return and sample quality: a linear method, where sites of interest are studied in the order encountered, and a "walkabout-first" method, where sites of interest are examined remotely before down-selecting to a subset of sites that are interrogated with more resource-intensive instruments. The walkabout method cost less time and fewer resources, while increasing confidence in interpretations. Contextual data critical to evaluating site geology was acquired earlier than for the linear method, and given a higher priority, which resulted in development of more mature hypotheses earlier in the analysis process. Combined, this saved time and energy in the collection of data with more limited spatial coverage. Based on these results, we suggest that the walkabout method be used where doing so would provide early context and time for the science team to develop hypotheses-critical tests; and that in gathering context, coverage may be more important than higher resolution.

  19. Component Selection, Accelerated Testing, and Improved Modeling of AMTEC Systems for Space Power (abstract)

    Williams, R. M.; Jeffries-Nakamura, B.; Ryan, M. A.; Underwood, M. L.; Suitor, J.; O'Connor, D.

    1993-01-01

    Alkali metal thermal to electric converter (AMTEC) designs for space power are numerous, but selection of materials for construction of long-lived AMTEC devices has been limited to electrodes, current collectors, and the solid electrolyte. AMTEC devices with lifetimes greater than 5 years require careful selection and life testing of all hot-side components. The likely selection of a remote condensed design for initial flight test and probable use with a GPHS in AMTEC powered outer planet probes requires the device to be constructed to tolerate T greater than 1150K, as well as exposure to Na(sub (g)), and Na(sub (liq)) on the high pressure side. The temperatures involved make critical high strength and chemical resistance to Na containing Na(sub 2)O. Selection among materials which can be worked should not be driven by ease of fabricability, as high temperature stability is the critical issue. These concepts drive the selection of Mo alloys for Na(sub (liq)) containment in AMTEC cells for T to 1150K operation, as they are significantly stronger than comparable NB or Ta alloys, are less soluble in Na(sub (liq)) containing dissolved Na(sub 2)O, are workable compared to W alloys (which might be used for certain components), and are ductile at the T greater than 500K of proposed AMTEC modules in space applications.

  20. Experimental power reactor dc generator energy storage study

    Heck, F.M.; Smeltzer, G.S.; Myers, E.H.; Kilgore, L.

    1978-01-01

    This study covers the use of dc generators for meeting the Experimental Power Reactor Ohmic Heating Energy Storage Requirements. The dc generators satisfy these requirements which are the same as defined in WFPS-TME-038 which covered the use of ac generators and homopolar generators. The costs of the latter two systems have been revised to eliminate first-of-a-kind factors. The cost figures for dc generators indicate a need to develop larger machines in order to take advantage of the economy-of-scale that the large ac machines have. Each of the systems has its own favorable salient features on which to base a system selection

  1. A DC Transformer

    Youngquist, Robert C.; Ihlefeld, Curtis M.; Starr, Stanley O.

    2013-01-01

    A component level dc transformer is described in which no alternating currents or voltages are present. It operates by combining features of a homopolar motor and a homopolar generator, both de devices, such that the output voltage of a de power supply can be stepped up (or down) with a corresponding step down (or up) in current. The basic theory for this device is developed, performance predictions are made, and the results from a small prototype are presented. Based on demonstrated technology in the literature, this de transformer should be scalable to low megawatt levels, but it is more suited to high current than high voltage applications. Significant development would be required before it could achieve the kilovolt levels needed for de power transmission.

  2. Analog Fiber Optic Link with DC-100 MHz Bandwidth

    Sullivan, C. A; Girardi, P. G; Lohrmann, Dieter R

    2008-01-01

    An analog fiber optic link covering the frequency range from DC to 100 MHz was designed, constructed, and tested, in order to connect a 10 kA pulse current probe to oscilloscopes for oscillographing...

  3. Selection of hidden layer nodes in neural networks by statistical tests

    Ciftcioglu, Ozer

    1992-05-01

    A statistical methodology for selection of the number of hidden layer nodes in feedforward neural networks is described. The method considers the network as an empirical model for the experimental data set subject to pattern classification so that the selection process becomes a model estimation through parameter identification. The solution is performed for an overdetermined estimation problem for identification using nonlinear least squares minimization technique. The number of the hidden layer nodes is determined as result of hypothesis testing. Accordingly the redundant network structure with respect to the number of parameters is avoided and the classification error being kept to a minimum. (author). 11 refs.; 4 figs.; 1 tab

  4. The performance of the DC motor by the PID controlling PWM DC-DC boost converter

    Can, Erol; Sayan, Hasan Hüseyin

    2017-01-01

    This paper presents the PID controlling direct current (DC) to the direct current boost converter feds DC motor which has a 3.68 kW and 240 V of DC voltage input on its characteristics. What is first formed is the boost converter mathematical model at the design stage. Secondly, a mathematical model of the DC motor is created so that the boost converter with the machine can be established and modeled at the Matlab Simulink. The PID controller is considered for arranging a pulse width modulati...

  5. Selective versus routine patch metal allergy testing to select bar material for the Nuss procedure in 932 patients over 10years.

    Obermeyer, Robert J; Gaffar, Sheema; Kelly, Robert E; Kuhn, M Ann; Frantz, Frazier W; McGuire, Margaret M; Paulson, James F; Kelly, Cynthia S

    2018-02-01

    The aim of the study was to determine the role of patch metal allergy testing to select bar material for the Nuss procedure. An IRB-approved (11-04-WC-0098) single institution retrospective, cohort study comparing selective versus routine patch metal allergy testing to select stainless steel or titanium bars for Nuss repair was performed. In Cohort A (9/2004-1/2011), selective patch testing was performed based on clinical risk factors. In Cohort B (2/2011-9/2014), all patients were patch tested. The cohorts were compared for incidence of bar allergy and resultant premature bar loss. Risk factors for stainless steel allergy or positive patch test were evaluated. Cohort A had 628 patients with 63 (10.0%) selected for patch testing, while all 304 patients in Cohort B were tested. Over 10years, 15 (1.8%) of the 842 stainless steel Nuss repairs resulted in a bar allergy, and 5 had a negative preoperative patch test. The incidence of stainless steel bar allergy (1.8% vs 1.7%, p=0.57) and resultant bar loss (0.5% vs 1.3%, p=0.23) was not statistically different between cohorts. An allergic reaction to a stainless steel bar or a positive patch test was more common in females (OR=2.3, pbar allergies occur at a low incidence with either routine or selective patch metal allergy testing. If selective testing is performed, it is advisable in females and patients with a personal or family history of metal sensitivity. A negative preoperative patch metal allergy test does not preclude the possibility of a postoperative stainless steel bar allergy. Level III Treatment Study and Study of Diagnostic Test. Copyright © 2017 Elsevier Inc. All rights reserved.

  6. A fast multilocus test with adaptive SNP selection for large-scale genetic-association studies

    Zhang, Han

    2013-09-11

    As increasing evidence suggests that multiple correlated genetic variants could jointly influence the outcome, a multilocus test that aggregates association evidence across multiple genetic markers in a considered gene or a genomic region may be more powerful than a single-marker test for detecting susceptibility loci. We propose a multilocus test, AdaJoint, which adopts a variable selection procedure to identify a subset of genetic markers that jointly show the strongest association signal, and defines the test statistic based on the selected genetic markers. The P-value from the AdaJoint test is evaluated by a computationally efficient algorithm that effectively adjusts for multiple-comparison, and is hundreds of times faster than the standard permutation method. Simulation studies demonstrate that AdaJoint has the most robust performance among several commonly used multilocus tests. We perform multilocus analysis of over 26,000 genes/regions on two genome-wide association studies of pancreatic cancer. Compared with its competitors, AdaJoint identifies a much stronger association between the gene CLPTM1L and pancreatic cancer risk (6.0 × 10(-8)), with the signal optimally captured by two correlated single-nucleotide polymorphisms (SNPs). Finally, we show AdaJoint as a powerful tool for mapping cis-regulating methylation quantitative trait loci on normal breast tissues, and find many CpG sites whose methylation levels are jointly regulated by multiple SNPs nearby.

  7. 75 FR 61989 - Airworthiness Directives; McDonnell Douglas Corporation Model DC-8-31, DC-8-32, DC-8-33, DC-8-41...

    2010-10-07

    ... Airworthiness Directives; McDonnell Douglas Corporation Model DC- 8-31, DC-8-32, DC-8-33, DC-8-41, DC-8-42, and... to all of the McDonnell Douglas Corporation airplanes identified above. The existing AD currently... the following new airworthiness directive (AD): 2010-21-03 McDonnell Douglas Corporation: Amendment 39...

  8. Selection of sorption material for tests of pesticide permeation through protective clothing fabrics.

    Krzemińska, Sylwia; Nazimek, Teresa

    2004-01-01

    The paper presents the results of studies on selecting a solid sorption material for absorbing liquid crop protection agents which permeate samples of protective clothing fabrics. The sorption materials were investigated and selected with an assumption that they should have a high recovery coefficient for biologically active substances, used as active ingredients in crop protection agents, at a presumed, acceptably high level. The selected substances were determined with a gas chromatograph equipped with an electron capture detector (dichlorvos, cypermethrin and 2,4-D) and a nitrogen-phosphorus detector (carbofuran). The tests demonstrated that polypropylene melt-blown type unwoven cloth had high recovery coefficients for all 4 active ingredients proposed for the study. The highest recovery coefficient, -.97, was obtained for carbofuran. The recovery coefficients obtained for the 3 remaining substances were lower: .89 for cypermethrin and 2,4-D, and .84 for dichlorvos.

  9. Soot reduction under DC electric fields in counterflow non-premixed laminar ethylene flames

    Park, Daegeun

    2014-04-23

    The effects of DC electric fields on non-premixed ethylene flames in a counterflow burner were studied experimentally with a focus on the reduction of soot particles. The experiment was conducted by connecting a high voltage terminal and a ground terminal to a lower (fuel) and upper (oxidizer) nozzle, respectively. We applied direct current (DC) potentials in a range of -5 kV < Vdc < 5 kV. Uniform electric fields were then generated in the gap between the two nozzles. The experimental conditions were selected to cover both soot formation (SF) and soot formation oxidation (SFO) flames. The flames subjected to the negative electric fields moved toward the fuel nozzle because of an ionic wind due to the Lorentz force acting on the positive ions in the flames. In addition, the yellow luminosity significantly decreased, indicating changes in the sooting characteristics. To analyze the sooting characteristics under the electric fields, planar laser induced incandescence (PLII) and fluorescence (PLIF) techniques were used to visualize the soot, polycyclic aromatic hydrocarbons (PAHs), and OH radicals. The sooting limits in terms of the fuel and oxygen mole fractions were measured. No substantial soot formation due to the effects of the DC electric fields for the tested range of voltages and reactant mole fractions could be identified. The detailed flame behaviors and sooting characteristics under the DC electric fields are discussed. Copyright © Taylor & Francis Group, LLC.

  10. Sliding-Mode Control of a Charger/Discharger DC/DC Converter for DC-Bus Regulation in Renewable Power Systems

    Sergio Ignacio Serna-Garcés

    2016-03-01

    Full Text Available Stand-alone power systems based on renewable energy sources are used to replace generators based on fossil fuels. Those renewable power systems also require Energy Storage Devices (ESD interfaced by a charger/discharger power converter, which consist of a bidirectional DC/DC converter, and a DC bus. This paper proposes a single sliding-mode controller (SMC for the charger/discharger DC/DC converter to provide a stable DC bus voltage in any operation condition: charging or discharging the ESD, or even without any power exchange between the ESD and the DC bus. Due to the non-linear nature of the power converter, the SMC parameters are adapted on-line to ensure global stability in any operation condition. Such stability of the adaptive SMC is mathematically demonstrated using analytical expressions for the transversality, reachability and equivalent control conditions. Moreover, a design procedure for the adaptive SMC parameters is provided in order to ensure the dynamic response required for the correct operation of the load. Finally, simulations and experimental tests validate the proposed controller and design procedure.

  11. MicroCHP: Overview of selected technologies, products and field test results

    Kuhn, Vollrad [Berliner Energieagentur GmbH, Franzoesische Strasse 23, 10117 Berlin (Germany); Klemes, Jiri; Bulatov, Igor [Centre for Process Integration, CEAS, The University of Manchester, P.O. Box 88, M60 1QD Manchester (United Kingdom)

    2008-11-15

    This paper gives an overview on selected microCHP technologies and products with the focus on Stirling and steam machines. Field tests in Germany, the UK and some other EC countries are presented, assessed and evaluated. Test results show the overall positive performance with differences in sectors (domestic vs. small business). Some negative experiences have been received, especially from tests with the Stirling engines and the free-piston steam machine. There are still obstacles for market implementation. Further projects and tests of microCHP are starting in various countries. When positive results will prevail and deficiencies are eliminated, a way to large-scale production and market implementation could be opened. (author)

  12. Evaluation and selection of test methods for assessment of contaminated sediments in the Baltic Sea

    Lehtonen, Kari; Ahvo, Aino; Berezina, Nadya

    The purpose of the CONTEST project (2014-15) is to test, develop, evaluate and select suitable biological methods to be applied in the quantitative and qualitative assessment of toxicity of anthropogenically contaminated sediments in the Baltic Sea marine region. Here is presented results from...... showed large variability in the sensitivity of the different biotests. Most of the tests applied showed concentration-dependent effects on the test organisms. New experiments will be carried out in 2015. The CONTEST project is funded by the Nordic Council of Ministers and the Finnish Ministry...... a set of pilot experiments, which were performed by the participating laboratories. Chemical analysis of the contaminated harbour sediment chosen as the test matrix confirmed the presence of high concentrations of polycyclic aromatic hydrocarbons, organotins and trace metals, and the sediment...

  13. Triple voltage dc-to-dc converter and method

    Su, Gui-Jia

    2008-08-05

    A circuit and method of providing three dc voltage buses and transforming power between a low voltage dc converter and a high voltage dc converter, by coupling a primary dc power circuit and a secondary dc power circuit through an isolation transformer; providing the gating signals to power semiconductor switches in the primary and secondary circuits to control power flow between the primary and secondary circuits and by controlling a phase shift between the primary voltage and the secondary voltage. The primary dc power circuit and the secondary dc power circuit each further comprising at least two tank capacitances arranged in series as a tank leg, at least two resonant switching devices arranged in series with each other and arranged in parallel with the tank leg, and at least one voltage source arranged in parallel with the tank leg and the resonant switching devices, said resonant switching devices including power semiconductor switches that are operated by gating signals. Additional embodiments having a center-tapped battery on the low voltage side and a plurality of modules on both the low voltage side and the high voltage side are also disclosed for the purpose of reducing ripple current and for reducing the size of the components.

  14. Fatigue Life Assessment of Selected Engineering Materials Based on Modified Low-Cycle Fatigue Test

    M. Maj

    2013-01-01

    Full Text Available In this study, the mechanical tests were carried out on ductile iron of EN-GJS-600-3 grade and on grey cast iron of EN-GJL-250 grade.The fatigue life was evaluated in a modified low-cycle fatigue test (MLCF, which enables the determination of parameters resulting fromthe Manson-Coffin-Morrow relationship.The qualitative and quantitative metallographic studies conducted by light microscopy on selected samples of ductile iron with spheroidalgraphite and grey cast iron with lamellar graphite (showing only small variations in mechanical properties, confirmed also smallvariations in the geometrical parameters of graphite related with its content and morphological features.

  15. Fatigue Life Assessment of Selected Engineering Materials Based on Modified Low-Cycle Fatigue Test

    Maj M.

    2013-03-01

    Full Text Available In this study, the mechanical tests were carried out on ductile iron of EN-GJS-600-3 grade and on grey cast iron of EN-GJL-250 grade. The fatigue life was evaluated in a modified low-cycle fatigue test (MLCF, which enables the determination of parameters resulting from the Manson-Coffin-Morrow relationship. The qualitative and quantitative metallographic studies conducted by light microscopy on selected samples of ductile iron with spheroidal graphite and grey cast iron with lamellar graphite (showing only small variations in mechanical properties, confirmed also small variations in the geometrical parameters of graphite related with its content and morphological features.

  16. Continuous progeny testing, use and selection of proven bulls in Israel

    R. Bar-Anan

    1983-12-01

    Full Text Available The breeding policy of the Israeli Holstein-type dairy cattle is reviewed. The bulls are progeny tested on their daughters’ first three lactations. The traits evaluated are the following: milk, fat, yield persistency, fertility, incidence of mastitis, and % cullings for three most important reasons. The test analysis takes into account the genetic level of daughters’ contemporaries and maternal grandsires. The paper describes a general outline of the selection decisions in AI bulls. Considerable amount of imported semen is used for breeding young bulls. Breeding goals are discussed against the estimated genetic parameters for and between the given traits.

  17. Simulation technologies in networking and communications selecting the best tool for the test

    Pathan, Al-Sakib Khan; Khan, Shafiullah

    2014-01-01

    Simulation is a widely used mechanism for validating the theoretical models of networking and communication systems. Although the claims made based on simulations are considered to be reliable, how reliable they really are is best determined with real-world implementation trials.Simulation Technologies in Networking and Communications: Selecting the Best Tool for the Test addresses the spectrum of issues regarding the different mechanisms related to simulation technologies in networking and communications fields. Focusing on the practice of simulation testing instead of the theory, it presents

  18. Insulating and sheathing materials of electric and optical cables - Common test methods - Part 5-1: Methods specific to filling compounds - Drop-point - Separation of oil - Lower temperature brittleness - Total acid number - Absence of corrosive components - Permittivity at 23 °C - DC resistivity at 23 °C and 100 °C

    International Electrotechnical Commission. Geneva

    2004-01-01

    Specifies the test methods for filling compounds of electric cables used with telecommunication equipment. Gives the methods for drop-point, separation of oil, lower temperature brittleness, total acid number, absence of corrosive components, permittivity at 23 °C, d.c. resistivity at 23°C and 100°C.

  19. Criteria for validation and selection of cognitive tests for investigating the effects of foods and nutrients.

    de Jager, Celeste A; Dye, Louise; de Bruin, Eveline A; Butler, Laurie; Fletcher, John; Lamport, Daniel J; Latulippe, Marie E; Spencer, Jeremy P E; Wesnes, Keith

    2014-03-01

    This review is an output of the International Life Sciences Institute (ILSI) Europe Marker Initiative, which aims to identify evidence-based criteria for selecting adequate measures of nutrient effects on health through comprehensive literature review. Experts in cognitive and nutrition sciences examined the applicability of these proposed criteria to the field of cognition with respect to the various cognitive domains usually assessed to reflect brain or neurological function. This review covers cognitive domains important in the assessment of neuronal integrity and function, commonly used tests and their state of validation, and the application of the measures to studies of nutrition and nutritional intervention trials. The aim is to identify domain-specific cognitive tests that are sensitive to nutrient interventions and from which guidance can be provided to aid the application of selection criteria for choosing the most suitable tests for proposed nutritional intervention studies using cognitive outcomes. The material in this review serves as a background and guidance document for nutritionists, neuropsychologists, psychiatrists, and neurologists interested in assessing mental health in terms of cognitive test performance and for scientists intending to test the effects of food or food components on cognitive function.

  20. Present status of ESNIT (energy selective neutron irradiation test facility) program

    Noda, K.; Ohno, H.; Sugimoto, M.; Kato, Y.; Matsuo, H.; Watanabe, K.; Kikuchi, T.; Sawai, T.; Usui, T.; Oyama, Y.; Kondo, T.

    1994-01-01

    The present status of technical studies of a high energy neutron irradiation facility, ESNIT (energy selective neutron irradiation test facility), is summarized. Technological survey and feasibility studies of ESNIT have continued since 1988. The results of technical studies of the accelerator, the target and the experimental systems in ESNIT program were reviewed by an International Advisory Committee in February 1993. Recommendations for future R and D on ESNIT program are also summarized in this paper. ((orig.))

  1. GaN-based High Efficiency Bidirectional DC-DC Converter with 10 MHz Switching Frequency

    Kruse, Kristian; Zhang, Zhe; Elbo, Mads

    2017-01-01

    -isolated bidirectional DC-DC converter equipped with Gallium Nitride (GaN) semiconductor transistors is presented. The converter’s operation principles, zero-voltage switching (ZVS) constraints and dead-time effects are studied. Moreover, the optimization and tradeoffs on the adopted high-frequency inductor...... are achieved. Moreover, the measured losses can match the theoretically calculated counterparts well, therefore the design and analysis are verified. However, from the experimental test carried out, it can also be seen, that making a compact converter, even for a GaN-based one, operate at 10 MHz and 100 W...

  2. Impact of DC link control strategies on the power-flow convergence of integrated AC–DC systems

    Shagufta Khan

    2016-03-01

    Full Text Available For the power-flow solution of integrated AC–DC systems, five quantities are required to be solved per converter, against three independent equations available. These three equations consist of two basic converter equations and one DC network equation, corresponding to each converter. Thus, for solution, two additional equations are required. These two equations are derived from the control specifications adopted for the DC link. Depending on the application, several combinations of valid control specifications are possible. A set of valid control specifications constitutes a control strategy. It is observed that the control strategy adopted for the DC link strongly affects the power-flow convergence of integrated AC–DC systems. This paper investigates how different control strategies affect the power flow convergence of integrated AC–DC systems. Sequential method is used to solve the DC variables in the Newton Raphson (NR power flow model. Seven typical control strategies have been taken into consideration. This is validated by numerous case studies carried out with multiple DC links incorporated in the IEEE 118-bus and 300-bus test systems.

  3. Simulation Analysis of DC and Switching Impulse Superposition Circuit

    Zhang, Chenmeng; Xie, Shijun; Zhang, Yu; Mao, Yuxiang

    2018-03-01

    Surge capacitors running between the natural bus and the ground are affected by DC and impulse superposition voltage during operation in the converter station. This paper analyses the simulation aging circuit of surge capacitors by PSCAD electromagnetic transient simulation software. This paper also analyses the effect of the DC voltage to the waveform of the impulse voltage generation. The effect of coupling capacitor to the test voltage waveform is also studied. Testing results prove that the DC voltage has little effect on the waveform of the output of the surge voltage generator, and the value of the coupling capacitor has little effect on the voltage waveform of the sample. Simulation results show that surge capacitor DC and impulse superimposed aging test is feasible.

  4. Bi-Directional DC-DC Converter for PHEV Applications

    Abas Goodarzi

    2011-01-31

    Plug-In Hybrid Electric Vehicles (PHEV) require high power density energy storage system (ESS) for hybrid operation and high energy density ESS for Electric Vehicle (EV) mode range. However, ESS technologies to maximize power density and energy density simultaneously are not commercially feasible. The use of bi-directional DC-DC converter allows use of multiple energy storage, and the flexible DC-link voltages can enhance the system efficiency and reduce component sizing. This will improve fuel consumption, increase the EV mode range, reduce the total weight, reduce battery initial and life cycle cost, and provide flexibility in system design.

  5. Screening tests for hazard classification of complex waste materials – Selection of methods

    Weltens, R.; Vanermen, G.; Tirez, K.; Robbens, J.; Deprez, K.; Michiels, L.

    2012-01-01

    In this study we describe the development of an alternative methodology for hazard characterization of waste materials. Such an alternative methodology for hazard assessment of complex waste materials is urgently needed, because the lack of a validated instrument leads to arbitrary hazard classification of such complex waste materials. False classification can lead to human and environmental health risks and also has important financial consequences for the waste owner. The Hazardous Waste Directive (HWD) describes the methodology for hazard classification of waste materials. For mirror entries the HWD classification is based upon the hazardous properties (H1–15) of the waste which can be assessed from the hazardous properties of individual identified waste compounds or – if not all compounds are identified – from test results of hazard assessment tests performed on the waste material itself. For the latter the HWD recommends toxicity tests that were initially designed for risk assessment of chemicals in consumer products (pharmaceuticals, cosmetics, biocides, food, etc.). These tests (often using mammals) are not designed nor suitable for the hazard characterization of waste materials. With the present study we want to contribute to the development of an alternative and transparent test strategy for hazard assessment of complex wastes that is in line with the HWD principles for waste classification. It is necessary to cope with this important shortcoming in hazardous waste classification and to demonstrate that alternative methods are available that can be used for hazard assessment of waste materials. Next, by describing the pros and cons of the available methods, and by identifying the needs for additional or further development of test methods, we hope to stimulate research efforts and development in this direction. In this paper we describe promising techniques and argument on the test selection for the pilot study that we have performed on different

  6. Selective reporting of antibiotic susceptibility test results in European countries: an ESCMID cross-sectional survey.

    Pulcini, Céline; Tebano, Gianpiero; Mutters, Nico T; Tacconelli, Evelina; Cambau, Emmanuelle; Kahlmeter, Gunnar; Jarlier, Vincent

    2017-02-01

    Selective reporting of antibiotic susceptibility test (AST) results is one possible laboratory-based antibiotic stewardship intervention. The primary aim of this study was to identify where and how selective reporting of AST results is implemented in Europe both in inpatient and in outpatient settings. An ESCMID cross-sectional, self-administered, internet-based survey was conducted among all EUCIC (European Committee on Infection Control) or EUCAST (European Committee on Antimicrobial Susceptibility Testing) national representatives in Europe and Israel. Of 38 countries, 36 chose to participate in the survey. Selective reporting of AST results was implemented in 11/36 countries (31%), was partially implemented in 4/36 (11%) and was limited to local initiatives or was not adopted in 21/36 (58%). It was endorsed as standard of care by health authorities in only three countries. The organisation of selective reporting was everywhere discretionally managed by each laboratory, with a pronounced intra- and inter-country variability. The most frequent application was in uncomplicated community-acquired infections, particularly urinary tract and skin and soft-tissue infections. The list of reported antibiotics ranged from a few first-line options, to longer reports where only last-resort antibiotics were hidden. Several barriers to implementation were reported, mainly lack of guidelines, poor system support, insufficient resources, and lack of professionals' capability. In conclusion, selective reporting of AST results is poorly implemented in Europe and is applied with a huge heterogeneity of practices. Development of an international framework, based on existing initiatives and identified barriers, could favour its dissemination as one important element of antibiotic stewardship programmes. Copyright © 2017 Elsevier B.V. and International Society of Chemotherapy. All rights reserved.

  7. Coagulation Tests and Selected Biochemical Analytes in Dairy Cows with Hepatic Lipidosis

    S. Padilla-Arellanes

    2007-01-01

    Full Text Available The aim of this study was to determine the values and changes in conventional and optimised clotting tests, as well as in selected biochemical analytes during hepatic lipidosis in postpartum dairy cows. Ten healthy and ten Holstein cows with hepatic lipidosis were selected based upon clinical history, clinical examination, liver biopsy, flotation test and histological analysis of hepatic tissue. Prothrombin time (PT and partial thromboplastin time (PTT were determined in non-diluted and diluted blood plasma samples. Clotting times determined in diluted plasma samples were prolonged in cows with hepatic lipidosis and there was a difference in the PT value at both 50% and 25% plasma dilutions between both groups of animals (P = 0.004 and P = 0.001. Significant differences between healthy animals and cows with hepatic lipidosis were observed in blood serum values for free fatty acids (FFA, aspartate aminotransferase (AST and triacyglycerols (P = 0.001, P = 0.007 and P = 0.044, respectively. FFA and liver biopsy are better diagnostic indicators for hepatic lipidosis than coagulation tests. The optimised PT is prolonged in cows with hepatic lipidosis and can detect this alteration that cannot be appreciated using conventional PT test.

  8. Sleep deprivation selectively disrupts top-down adaptation to cognitive conflict in the Stroop test.

    Gevers, Wim; Deliens, Gaetane; Hoffmann, Sophie; Notebaert, Wim; Peigneux, Philippe

    2015-12-01

    Sleep deprivation is known to exert detrimental effects on various cognitive domains, including attention, vigilance and working memory. Seemingly at odds with these findings, prior studies repeatedly failed to evidence an impact of prior sleep deprivation on cognitive interference in the Stroop test, a hallmark paradigm in the study of cognitive control abilities. The present study investigated further the effect of sleep deprivation on cognitive control using an adapted version of the Stroop test that allows to segregate top-down (attentional reconfiguration on incongruent items) and bottom-up (facilitated processing after repetitions in responses and/or features of stimuli) components of performance. Participants underwent a regular night of sleep or a night of total sleep deprivation before cognitive testing. Results disclosed that sleep deprivation selectively impairs top-down adaptation mechanisms: cognitive control no longer increased upon detection of response conflict at the preceding trial. In parallel, bottom-up abilities were found unaffected by sleep deprivation: beneficial effects of stimulus and response repetitions persisted. Changes in vigilance states due to sleep deprivation selectively impact on cognitive control in the Stroop test by affecting top-down, but not bottom-up, mechanisms that guide adaptive behaviours. © 2015 European Sleep Research Society.

  9. Construct validity of the Free and Cued Selective Reminding Test in older adults with memory complaints.

    Clerici, Francesca; Ghiretti, Roberta; Di Pucchio, Alessandra; Pomati, Simone; Cucumo, Valentina; Marcone, Alessandra; Vanacore, Nicola; Mariani, Claudio; Cappa, Stefano Francesco

    2017-06-01

    The Free and Cued Selective Reminding Test (FCSRT) is the memory test recommended by the International Working Group on Alzheimer's disease (AD) for the detection of amnestic syndrome of the medial temporal type in prodromal AD. Assessing the construct validity and internal consistency of the Italian version of the FCSRT is thus crucial. The FCSRT was administered to 338 community-dwelling participants with memory complaints (57% females, age 74.5 ± 7.7 years), including 34 with AD, 203 with Mild Cognitive Impairment, and 101 with Subjective Memory Impairment. Internal Consistency was estimated using Cronbach's alpha coefficient. To assess convergent validity, five FCSRT scores (Immediate Free Recall, Immediate Total Recall, Delayed Free Recall, Delayed Total Recall, and Index of Sensitivity of Cueing) were correlated with three well-validated memory tests: Story Recall, Rey Auditory Verbal Learning test, and Rey Complex Figure (RCF) recall (partial correlation analysis). To assess divergent validity, a principal component analysis (an exploratory factor analysis) was performed including, in addition to the above-mentioned memory tasks, the following tests: Word Fluencies, RCF copy, Clock Drawing Test, Trail Making Test, Frontal Assessment Battery, Raven Coloured Progressive Matrices, and Stroop Colour-Word Test. Cronbach's alpha coefficients for immediate recalls (IFR and ITR) and delayed recalls (DFR and DTR) were, respectively, .84 and .81. All FCSRT scores were highly correlated with those of the three well-validated memory tests. The factor analysis showed that the FCSRT does not load on the factors saturated by non-memory tests. These findings indicate that the FCSRT has a good internal consistency and has an excellent construct validity as an episodic memory measure. © 2015 The British Psychological Society.

  10. RESONANT STEP-DOWN DC-DC POWER CONVERTERS

    2015-01-01

    The present invention relates to a resonant step-down DC-DC power converter which comprises a primary side circuit and a secondary side circuit coupled through a galvanic isolation barrier. The primary side circuit comprises a positive and a negative input terminal for receipt of an input voltage...... charged from the input voltage and discharged to the output capacitor through the galvanic isolation barrier by a semiconductor switch arrangement in accordance with a switch control signal to produce the converter output voltage. The resonant step-down DC-DC power converter comprises an electrical short......-circuit connection across the galvanic isolation barrier connecting, in a first case, the second negative electrode of the output capacitor to the positive input terminal of the primary side circuit or, in a second case, connecting the second positive electrode of the output capacitor to the negative input terminal...

  11. Decentralized Interleaving of Paralleled Dc-Dc Buck Converters: Preprint

    Johnson, Brian B [National Renewable Energy Laboratory (NREL), Golden, CO (United States); Rodriguez, Miguel [National Renewable Energy Laboratory (NREL), Golden, CO (United States); Sinha, Mohit [University of Minnesota; Dhople, Sairaj [University of Minnesota; Poon, Jason [University of California at Berkeley

    2017-09-01

    We present a decentralized control strategy that yields switch interleaving among parallel connected dc-dc buck converters without communication. The proposed method is based on the digital implementation of the dynamics of a nonlinear oscillator circuit as the controller. Each controller is fully decentralized, i.e., it only requires the locally measured output current to synthesize the pulse width modulation (PWM) carrier waveform. By virtue of the intrinsic electrical coupling between converters, the nonlinear oscillator-based controllers converge to an interleaved state with uniform phase-spacing across PWM carriers. To the knowledge of the authors, this work represents the first fully decentralized strategy for switch interleaving of paralleled dc-dc buck converters.

  12. Active pre-filters for dc/dc Boost regulators

    Carlos Andrés Ramos-Paja

    2014-05-01

    Full Text Available This paper proposes an active pre-filter to mitigate the current harmonics generated by classical dc/dc Boost regulators, which generate current ripples proportional to the duty cycle. Therefore, high output voltage conditions, i.e., high voltage conversion ratios, produce high current harmonics that must be filtered to avoid damage or source losses. Traditionally, these current components are filtered using electrolytic capacitors, which introduce reliability problems because of their high failure rate. The solution introduced in this paper instead uses a dc/dc converter based on the parallel connection of the Boost canonical cells to filter the current ripples generated by the Boost regulator, improving the system reliability. This solution provides the additional benefits of improving the overall efficiency and the voltage conversion ratio. Finally, the solution is validated with simulations and experimental results.

  13. Eficiência do CCB na resistência da madeira de algaroba (Prosopis juliflora (Sw. D.C. em ensaio de apodrecimento acelerado Efficiency of CCB on resistance of Prosopis juliflora (Sw. D.C. wood in accelerated laboratory test decay

    Ildefonso Egydio Coutinho Ramos

    2006-10-01

    Full Text Available O objetivo da pesquisa foi avaliar o efeito do preservativo "Osmose CCB" na resistência da madeira de algaroba (Prosopis juliflora (Sw D.C. ao fungo Postia placenta, em condições de laboratório. Peças roliças de algaroba foram tratadas pelo método de substituição da seiva por transpiração radial, em soluções de 1, 2 e 3% de ingredientes ativos de CCB, durante 3, 6, 9, 12 e 15 dias. Das peças tratadas foram retirados discos em três posições (50 cm da base, meio do comprimento e topo da peça, em que foram analisadas a penetração e retenção do CCB, bem como a resistência ao fungo Postia placenta. Observou-se melhor penetração e retenção nas peças submetidas a 2% de ingredientes ativos. A penetração e retenção do CCB, assim como a resistência conferida à madeira, de modo geral, decresceram da base para o topo das peças. O tratamento preservativo conferiu às peças de algaroba uma alta resistência ao fungo P. placenta. Isso não ocorreu apenas nas amostras provenientes do topo (submetidas a 1% de CCB e 15 dias de tratamento; 2% e 9 dias; 3% e 3, 12 e 15 dias e meio das peças (3% de CCB e 3 e 12 dias de tratamento, que foram classificadas como resistentes.The objective of research was to analyze the "Osmose CCB" preservative efficiency to improve the wood Prosopis juliflora (Sw D.C. resistance to Postia placenta fungus. In order to meet the objectives proposed, round pieces of P. juliflora were treated by sap displaced method in 1; 2 and 3% of active ingredients of CCB solutions, by 3, 6, 9, 12 and 15 days. Wood disks were obtained at three positions (50 cm from the base, middle and top of the treated pieces. CCB penetration and retention were analyzed at these positions, as well as the resistance to P. placenta fungus (accelerated laboratory test decay It was found better penetration and retention in pieces submitted to 2% of CCB solutions. The CCB penetration and retention, as well as the resistance of treated

  14. Endogenous information, adverse selection, and prevention: Implications for genetic testing policy.

    Peter, Richard; Richter, Andreas; Thistle, Paul

    2017-09-01

    We examine public policy toward the use of genetic information by insurers. Individuals engage in unobservable primary prevention and have access to different prevention technologies. Thus, insurance markets are affected by moral hazard and adverse selection. Individuals can choose to take a genetic test to acquire information about their prevention technology. Information has positive decision-making value, that is, individuals may adjust their behavior based on the result of the test. However, testing also exposes individuals to uncertainty over the available insurance contract, so-called classification risk, which lowers the value of information. In our analysis we distinguish between four different policy regimes, determine the value of information under each regime and associated equilibrium outcomes on the insurance market. We show that the policy regimes can be Pareto ranked, with a duty to disclose being the preferred regime and an information ban the least preferred one. Copyright © 2017 Elsevier B.V. All rights reserved.

  15. The director task: A test of Theory-of-Mind use or selective attention?

    Rubio-Fernández, Paula

    2017-08-01

    Over two decades, the director task has increasingly been employed as a test of the use of Theory of Mind in communication, first in psycholinguistics and more recently in social cognition research. A new version of this task was designed to test two independent hypotheses. First, optimal performance in the director task, as established by the standard metrics of interference, is possible by using selective attention alone, and not necessarily Theory of Mind. Second, pragmatic measures of Theory-of-Mind use can reveal that people actively represent the director's mental states, contrary to recent claims that they only use domain-general cognitive processes to perform this task. The results of this study support both hypotheses and provide a new interactive paradigm to reliably test Theory-of-Mind use in referential communication.

  16. DC8 and DC13 var genes associated with severe malaria bind avidly to diverse endothelial cells.

    Marion Avril

    Full Text Available During blood stage infection, Plasmodium falciparum infected erythrocytes (IE bind to host blood vessels. This virulence determinant enables parasites to evade spleen-dependent killing mechanisms, but paradoxically in some cases may reduce parasite fitness by killing the host. Adhesion of infected erythrocytes is mediated by P. falciparum erythrocyte membrane protein 1 (PfEMP1, a family of polymorphic adhesion proteins encoded by var genes. Whereas cerebral binding and severe malaria are associated with parasites expressing DC8 and DC13 var genes, relatively little is known about the non-brain endothelial selection on severe malaria adhesive types. In this study, we selected P. falciparum-IEs on diverse endothelial cell types and demonstrate that DC8 and DC13 var genes were consistently among the major var transcripts selected on non-brain endothelial cells (lung, heart, bone marrow. To investigate the molecular basis for this avid endothelial binding activity, recombinant proteins were expressed from the predominant upregulated DC8 transcript, IT4var19. In-depth binding comparisons revealed that multiple extracellular domains from this protein bound brain and non-brain endothelial cells, and individual domains largely did not discriminate between different endothelial cell types. Additionally, we found that recombinant DC8 and DC13 CIDR1 domains exhibited a widespread endothelial binding activity and could compete for DC8-IE binding to brain endothelial cells, suggesting they may bind the same host receptor. Our findings provide new insights into the interaction of severe malaria adhesive types and host blood vessels and support the hypothesis that parasites causing severe malaria express PfEMP1 variants with a superior ability to adhere to diverse endothelial cell types, and may therefore endow these parasites with a growth and transmission advantage.

  17. Linking DC together with TRSL

    Haxthausen, Anne Elisabeth; Yong, X.

    2000-01-01

    in a method for real-time developments. An operational semantics with behavior is specified for TRSL. It is defined what its means for a TRSL process to satisfy a DC requirement, and a method for verifying whether the satisfaction relation holds or not is provided. Our contribution also demonstrates a general......Duration Calculus (DC) is an interval-based real-time logic, which can be used in capturing and eliciting users' real-time requirements. The Timed RAISE Specification Language (TRSL) is an extension of the RAISE Specification Language with real-time features. This paper links DC and TRSL together...

  18. DC Microgrids—Part II

    Dragicevic, Tomislav; Lu, Xiaonan; Quintero, Juan Carlos Vasquez

    2016-01-01

    distribution applications such as traction, telecom, vehicular and distributed power systems can be classified under DC MG framework and ongoing development and expansion of the field is largely influenced by concepts used over there. This paper aims firstly to shed light on the practical design aspects of DC...... MG technology concerning typical power hardware topologies and their suitability for different emerging smart grid applications. Then, an overview of the state of the art in DC MG protection and grounding is provided. Owing to the fact that there is no zero current crossing, an arc that appears upon...

  19. DC-Compensated Current Transformer.

    Ripka, Pavel; Draxler, Karel; Styblíková, Renata

    2016-01-20

    Instrument current transformers (CTs) measure AC currents. The DC component in the measured current can saturate the transformer and cause gross error. We use fluxgate detection and digital feedback compensation of the DC flux to suppress the overall error to 0.15%. This concept can be used not only for high-end CTs with a nanocrystalline core, but it also works for low-cost CTs with FeSi cores. The method described here allows simultaneous measurements of the DC current component.

  20. Autonomous economic operation of grid connected DC microgrid

    Nutkani, Inam Ullah; Wang, Peng; Loh, Poh Chiang

    2014-01-01

    This paper presents an autonomous power sharing scheme for economic operation of grid-connected DC microgrid. Autonomous economic operation approach has already been tested for standalone AC microgrids to reduce the overall generation cost and proven a simple and easier to realize compared...... with the centralized management approach. In this paper, the same concept has been extended to grid-connected DC microgrid. The proposed economic droop scheme takes into consideration the power generation cost of Distributed Generators (DGs) and utility grid tariff and adaptively tunes their respective droop curves...... secondary control. The performance of the proposed scheme has been verified for the example grid-connected DC microgrid....

  1. ANTIOXIDANT ACTIVITY OF ETHANOLIC EXTRACT FROM RUMEX CRISTATUS DC

    Sibel KAHRAMAN

    2013-01-01

    Full Text Available Plants have been used for many years as a source of traditional medicine to treat various diseases and conditions. R. cristatus DC (Polygonaceae is widely spread in Turkey and used as both herbal medicine and food. This study examined the antioxidant activities of ethanolic extract of R. cristatus DC using different tests. The antioxidant activity of ethanolic extract of R. cristatus leaves was analyzed for total phenolic, flavonoid, ascorbic acid and β-carotene contents, reducing power and DPPH radical scavenging activity. The results were compared with natural and synthetic antioxidants. The results suggest that consumption of R. cristatus DC can be beneficial effects due to its antioxidant properties

  2. Selfish spermatogonial selection: evidence from an immunohistochemical screen in testes of elderly men.

    Jasmine Lim

    Full Text Available The dominant congenital disorders Apert syndrome, achondroplasia and multiple endocrine neoplasia-caused by specific missense mutations in the FGFR2, FGFR3 and RET proteins respectively-represent classical examples of paternal age-effect mutation, a class that arises at particularly high frequencies in the sperm of older men. Previous analyses of DNA from randomly selected cadaveric testes showed that the levels of the corresponding FGFR2, FGFR3 and RET mutations exhibit very uneven spatial distributions, with localised hotspots surrounded by large mutation-negative areas. These studies imply that normal testes are mosaic for clusters of mutant cells: these clusters are predicted to have altered growth and signalling properties leading to their clonal expansion (selfish spermatogonial selection, but DNA extraction eliminates the possibility to study such processes at a tissue level. Using a panel of antibodies optimised for the detection of spermatocytic seminoma, a rare tumour of spermatogonial origin, we demonstrate that putative clonal events are frequent within normal testes of elderly men (mean age: 73.3 yrs and can be classed into two broad categories. We found numerous small (less than 200 cells cellular aggregations with distinct immunohistochemical characteristics, localised to a portion of the seminiferous tubule, which are of uncertain significance. However more infrequently we identified additional regions where entire seminiferous tubules had a circumferentially altered immunohistochemical appearance that extended through multiple serial sections that were physically contiguous (up to 1 mm in length, and exhibited enhanced staining for antibodies both to FGFR3 and a marker of downstream signal activation, pAKT. These findings support the concept that populations of spermatogonia in individual seminiferous tubules in the testes of older men are clonal mosaics with regard to their signalling properties and activation, thus fulfilling

  3. DC injection into low voltage AC networks

    NONE

    2005-07-01

    This report summarises the results of a study investigating the impact of levels of injected DC current injections on a low voltage AC distribution network systems in order to recommend acceptable limits of DC from microgeneration. Relevant literature is reviewed, and the impact of DC levels in distribution transformers, transformer modelling, and instrumental transformers are discussed. The impact of DC in residual current devices (RCD) and in domestic electricity watt hour meters is examined along with DC enhanced corrosion, corrosion failure, and the measurement of DC current injection. Sources of DC injection outlined include DC from computer power supplies, network faults, geomagnetic phenomena, lighting circuits/dimmers, and embedded generators.

  4. Using a situational judgement test for selection into dental core training: a preliminary analysis.

    Rowett, E; Patterson, F; Cousans, F; Elley, K

    2017-05-12

    Objective and setting This paper describes the evaluation of a pilot situational judgement test (SJT) for selection into UK Dental Core Training (DCT). The SJT's psychometric properties, group differences based on gender and ethnicity, and candidate reactions were assessed.Methods The SJT targets four non-academic attributes important for success in DCT. Data were collected alongside live selection processes from five Health Education England local teams in the UK (N = 386). Candidates completed the pilot SJT and an evaluation questionnaire to examine their reactions to the test.Results SJT scores were relatively normally distributed and showed acceptable levels of internal reliability (α = 0.68). Difficulty level and partial correlations between scenarios and SJT total score were in the expected ranges (64.61% to 90.03% and r = 0.06 to 0.41, respectively). No group differences were found for gender, and group differences between White and BME candidates were minimal. Most candidates perceived the SJT as relevant to the target role, appropriate and fair.Conclusions This study demonstrated the potential suitability of an SJT for use in DCT selection. Future research should replicate these preliminary findings in other cohorts, and assess the predictive validity of the SJT for predicting key training and practice-based outcomes.

  5. A multicenter study of routine versus selective intraoperative leak testing for sleeve gastrectomy.

    Bingham, Jason; Kaufman, Jedediah; Hata, Kai; Dickerson, James; Beekley, Alec; Wisbach, Gordon; Swann, Jacob; Ahnfeldt, Eric; Hawkins, Devon; Choi, Yong; Lim, Robert; Martin, Matthew

    2017-09-01

    Staple line leaks after sleeve gastrectomy are dreaded complications. Many surgeons routinely perform an intraoperative leak test (IOLT) despite little evidence to validate the reliability, clinical benefit, and safety of this procedure. To determine the efficacy of IOLT and if routine use has any benefit over selective use. Eight teaching hospitals, including private, university, and military facilities. A multicenter, retrospective analysis over a 5-year period. The efficacy of the IOLT for identifying unsuspected staple line defects and for predicting postoperative leaks was evaluated. An anonymous survey was also collected reflecting surgeons' practices and beliefs regarding IOLT. From January 2010 through December 2014, 4284 patients underwent sleeve gastrectomy. Of these, 37 patients (.9%) developed a postoperative leak, and 2376 patients (55%) received an IOLT. Only 2 patients (0.08%) had a positive finding. Subsequently, 21 patients with a negative IOLT developed a leak. IOLT demonstrated a sensitivity of only 8.7%. There was a nonsignificant trend toward increased leak rates when an IOLT was performed versus when IOLT was not performed. Leak rates were not statistically different between centers that routinely perform IOLT versus those that selectively perform IOLT. Routine IOLT had very poor sensitivity and was negative in 91% of patients who later developed postoperative leaks. The use of IOLT was not associated with a decrease in the incidence of postoperative leaks, and routine IOLT had no benefit over selective leak testing. IOLT should not be used as a quality indicator or "best practice" for bariatric surgery. Published by Elsevier Inc.

  6. Isolated step-down DC -DC converter for electric vehicles

    Kukovinets, O. V.; Sidorov, K. M.; Yutt, V. E.

    2018-02-01

    Modern motor-vehicle industrial sector is moving rapidly now towards the electricity-driving cars production, improving their range and efficiency of components, and in particular the step-down DC/DC converter to supply the onboard circuit 12/24V of electric vehicle from the high-voltage battery. The purpose of this article - to identify the best circuitry topology to design an advanced step-down DC/DC converters with the smallest mass, volume, highest efficiency and power. And this will have a positive effect on driving distance of electric vehicle (EV). On the basis of computational research of existing and implemented circuit topologies of step-down DC/DC converters (serial resonant converter, full bridge with phase-shifting converter, LLC resonant converter) a comprehensive analysis was carried out on the following characteristics: specific volume, specific weight, power, efficiency. The data obtained was the basis for the best technical option - LLC resonant converter. The results can serve as a guide material in the process of components design of the traction equipment for electric vehicles, providing for the best technical solutions in the design and manufacturing of converting equipment, self-contained power supply systems and advanced driver assistance systems.

  7. Medical school dropout--testing at admission versus selection by highest grades as predictors.

    O'Neill, Lotte; Hartvigsen, Jan; Wallstedt, Birgitta; Korsholm, Lars; Eika, Berit

    2011-11-01

    Very few studies have reported on the effect of admission tests on medical school dropout. The main aim of this study was to evaluate the predictive validity of non-grade-based admission testing versus grade-based admission relative to subsequent dropout. This prospective cohort study followed six cohorts of medical students admitted to the medical school at the University of Southern Denmark during 2002-2007 (n=1544). Half of the students were admitted based on their prior achievement of highest grades (Strategy 1) and the other half took a composite non-grade-based admission test (Strategy 2). Educational as well as social predictor variables (doctor-parent, origin, parenthood, parents living together, parent on benefit, university-educated parents) were also examined. The outcome of interest was students' dropout status at 2 years after admission. Multivariate logistic regression analysis was used to model dropout. Strategy 2 (admission test) students had a lower relative risk for dropping out of medical school within 2 years of admission (odds ratio 0.56, 95% confidence interval 0.39-0.80). Only the admission strategy, the type of qualifying examination and the priority given to the programme on the national application forms contributed significantly to the dropout model. Social variables did not predict dropout and neither did Strategy 2 admission test scores. Selection by admission testing appeared to have an independent, protective effect on dropout in this setting. © Blackwell Publishing Ltd 2011.

  8. Selection of reference soils for chemicals testing in the European Community

    Kuhnt, G.; Hertling, T.; Schmotz, W.; Vetter, L.; Fraenzle, M.; Geissler, S.; Knabe, I.; Maass, R.; Struckmeyer, A.; Heinrich, U.

    1991-01-01

    Based on an multivariate statistical evaluation of binary and metric data relating to the soil cover of the European Community five regionally representative reference soils (EURO-Soils) have been identified for chemicals testing in the EC. The soil material sampled at representative localities in Italy, Greece, Great Britain, France and Germany was treated and prepared according to OECD Test Guideline 106 and analysed in detail. The homogenised specimens were subject to an EC-wide ring test to evaluate the feasibility of the modified guideline and to validate the physical-chemical amenability of the reference soils for sorption tests. The results proved the validity of the soils selected for assessing the potential behaviour of new chemicals in soil on the basis of a comparative evaluation of the individual test results obtained. In the light of this parametric assessment potential test soils were subsequently identified in the individual EC Member States which correspond as far as possible to the above reference soils in terms of both taxonomy and sorption-relevant properties. (orig.). 164 refs., 30 tabs., 24 figs [de

  9. Development and test of selective sorting grids used in the Norway lobster (Nephrops norvegicus) fishery

    Madsen, Niels; Holst, René; Frandsen, Rikke

    2017-01-01

    Due to generally high discard rates in Norway lobster (Nephrops norvegicus) fisheries, a discard ban coming up and to the cod recovery plan in several areas, selective sorting grids have been tested in many areas and are specified by legislation for use in the Kattegat and Skagerrak area bordering...... Norway, Denmark and Sweden. Grids are very selective, but they can lead to loss of landable Norway lobster and valuable fish species. To improve retention of these species, we developed three new grids using made by polyurethane to make them flexible: One grid had horizontal bars, one had vertical bars....... More flatfish passed the grid with horizontal bars compared to that with vertical bars, but the retention rate was still low. Use of the guiding funnel increased the contact with the grid considerably for both target and unwanted species. In all three grid designs, there were losses of Norway lobster...

  10. Efficiency of a clinical prediction model for selective rapid testing in children with pharyngitis: A prospective, multicenter study

    Cohen, Jérémie F.; Cohen, Robert; Bidet, Philippe; Elbez, Annie; Levy, Corinne; Bossuyt, Patrick M.; Chalumeau, Martin

    2017-01-01

    There is controversy whether physicians can rely on signs and symptoms to select children with pharyngitis who should undergo a rapid antigen detection test (RADT) for group A streptococcus (GAS). Our objective was to evaluate the efficiency of signs and symptoms in selectively testing children with

  11. Improved DC Gun Insulator Assembly

    Neubauer, M.L.; Dudas, A.; Sah, R.; Poelker, M.; Surles-Law, K.E.L.

    2010-01-01

    Many user facilities such as synchrotron radiation light sources and free electron lasers require accelerating structures that support electric fields of 10-100 MV/m, especially at the start of the accelerator chain where ceramic insulators are used for very high gradient DC guns. These insulators are difficult to manufacture, require long commissioning times, and often exhibit poor reliability. Two technical approaches to solving this problem will be investigated. Firstly, inverted ceramics offer solutions for reduced gradients between the electrodes and ground. An inverted design will be presented for 350 kV, with maximum gradients in the range of 5-10 MV/m. Secondly, novel ceramic manufacturing processes will be studied, in order to protect triple junction locations from emission, by applying a coating with a bulk resistivity. The processes for creating this coating will be optimized to provide protection as well as be used to coat a ceramic with an appropriate gradient in bulk resistivity from the vacuum side to the air side of an HV standoff ceramic cylinder. Example insulator designs are being computer modelled, and insulator samples are being manufactured and tested

  12. Integrating DC/DC Conversion with Possible Reconfiguration within Submodule Solar Photovoltaic Systems

    Huang, Peter Jen-Hung

    This research first proposes a method to merge photovoltaic (PV) cells or PV panels within the internal components DC-DC converters. The purpose of this merged structure is to reconfigure the PV modules between series and parallel connections using high switching frequencies (hundreds of kHz). This leads to multi-levels of voltages and currents that become applied to the output filter of the converter. Further, this research introduces a concept of a switching cell that utilizes the reconfiguration of series and parallel connections in DC-DC converters. The switching occurs at high switching frequency and the switches can be integrated to be within the solar panels or in between the solar cells. The concept is generalized and applied to basic buck and boost topologies. As examples of the new types of converters: reconfigurable PV-buck and PV-boost converter topologies are presented. It is also possible to create other reconfigurable power converters: non-isolated and isolated topologies. Analysis, simulation and experimental verification for the reconfigurable PV-buck and PV-boost converters are presented extensively to illustrate proof of concept. Benefits and drawbacks of the new approach are discussed. The second part of this research proposes to utilize the internal solar cell capacitance and internal solar module wire parasitic inductances to replace the input capacitor and filter inductor in boost derived DC-DC converters for energy harvesting applications. High switching frequency (MHz) hard switched and resonant boost converters are proposed. Their analysis, simulation and experimental prototypes are presented. A specific proof-of-concept application is especially tested for foldable PV panels, which are known for their high internal wire inductance. The experimental converters successfully boost solar module voltage without adding any external input capacitance or filter inductor. Benefits and drawbacks of new proposed PV submodule integrated boost

  13. ANTIOXIDANT ACTIVITY OF ETHANOLIC EXTRACT FROM RUMEX CRISTATUS DC

    Sibel KAHRAMAN; Refiye YANARDAG

    2013-01-01

    Plants have been used for many years as a source of traditional medicine to treat various diseases and conditions. R. cristatus DC (Polygonaceae) is widely spread in Turkey and used as both herbal medicine and food. This study examined the antioxidant activities of ethanolic extract of R. cristatus DC using different tests. The antioxidant activity of ethanolic extract of R. cristatus leaves was analyzed for total phenolic, flavonoid, ascorbic acid and β-carotene contents, reducing power and ...

  14. Development of large-scale thyristor dc circuit breaker

    Kobayashi, S.; Tanoue, Y.; Ikegame, H.; Matushita, T.; Sato, Y.

    1981-01-01

    A study for developing a thyristor dc circuit breaker that is applicable to the Tokamak device for engineering feasibility is presented. The design and test of a unit circuit breaker consisting of 4kV-3kA thyristors connected 2 in series and 12 in parallel are described. And based on the results a 50kV-24kA thyristor dc circuit breaker is conceptually designed

  15. Performance analysis of pulse analog control schemes for LLC resonant DC/DC converters suitable in portable applications

    P. Kowstubha

    2016-12-01

    Full Text Available Performance Analysis of Pulse Analog Control Schemes, predominantly Pulse-Width Modulation (PWM and Pulse-Position Modulation (PPM for LLC resonant DC/DC converter suitable in portable applications is addressed in this paper. The analysis is done for closed loop performance, frequency domain performance, primary and secondary side conduction losses and soft commutation using PSIM 6.0 software and observed that PPM scheme provides better performance at high input voltage with a good selectivity of frequency over a wide range of line and load variations. The performance of LLC resonant DC/DC converter is demonstrated using PPM scheme for a design specifications of 12 V, 5 A output.

  16. Stability of selected volatile contact allergens in different patch test chambers under different storage conditions.

    Mose, Kristian F; Andersen, Klaus E; Christensen, Lars Porskjaer

    2012-04-01

    Patch test preparations of volatile substances may evaporate during storage, thereby giving rise to reduced patch test concentrations. To investigate the stability of selected acrylates/methacrylates and fragrance allergens in three different test chambers under different storage conditions. Petrolatum samples of methyl methacrylate (MMA), 2-hydroxyethyl methacrylate (2-HEMA), 2-hydroxypropyl acrylate (2-HPA), cinnamal and eugenol in patch test concentrations were stored in three different test chambers (IQ chamber™, IQ Ultimate™, and Van der Bend® transport container) at room temperature and in a refrigerator. The samples were analysed in triplicate with high-performance liquid chromatography. The decrease in concentration was substantial for all five allergens under both storage conditions in IQ chamber™ and IQ Ultimate™, with the exception of 2-HEMA during storage in the refrigerator. For these two chamber systems, the contact allergen concentration dropped below the stability limit in the following order: MMA, cinnamal, 2-HPA, eugenol, and 2-HEMA. In the Van der Bend® transport container, the contact allergens exhibited acceptable stability under both storage conditions, whereas MMA and 2-HPA required cool storage for maintenance of the limit. The Van der Bend® transport container was the best device for storage of samples of volatile contact allergens. © 2012 John Wiley & Sons A/S.

  17. Adaptive Test Selection for Factorization-based Surrogate Fitness in Genetic Programming

    Krawiec Krzysztof

    2017-12-01

    Full Text Available Genetic programming (GP is a variant of evolutionary algorithm where the entities undergoing simulated evolution are computer programs. A fitness function in GP is usually based on a set of tests, each of which defines the desired output a correct program should return for an exemplary input. The outcomes of interactions between programs and tests in GP can be represented as an interaction matrix, with rows corresponding to programs in the current population and columns corresponding to tests. In previous work, we proposed SFIMX, a method that performs only a fraction of interactions and employs non-negative matrix factorization to estimate the outcomes of remaining ones, shortening GP’s runtime. In this paper, we build upon that work and propose three extensions of SFIMX, in which the subset of tests drawn to perform interactions is selected with respect to test difficulty. The conducted experiment indicates that the proposed extensions surpass the original SFIMX on a suite of discrete GP benchmarks.

  18. Mean Abnormal Result Rate: Proof of Concept of a New Metric for Benchmarking Selectivity in Laboratory Test Ordering.

    Naugler, Christopher T; Guo, Maggie

    2016-04-01

    There is a need to develop and validate new metrics to access the appropriateness of laboratory test requests. The mean abnormal result rate (MARR) is a proposed measure of ordering selectivity, the premise being that higher mean abnormal rates represent more selective test ordering. As a validation of this metric, we compared the abnormal rate of lab tests with the number of tests ordered on the same requisition. We hypothesized that requisitions with larger numbers of requested tests represent less selective test ordering and therefore would have a lower overall abnormal rate. We examined 3,864,083 tests ordered on 451,895 requisitions and found that the MARR decreased from about 25% if one test was ordered to about 7% if nine or more tests were ordered, consistent with less selectivity when more tests were ordered. We then examined the MARR for community-based testing for 1,340 family physicians and found both a wide variation in MARR as well as an inverse relationship between the total tests ordered per year per physician and the physician-specific MARR. The proposed metric represents a new utilization metric for benchmarking relative selectivity of test orders among physicians. © American Society for Clinical Pathology, 2016. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.

  19. Selected concrete spent fuel storage cask concepts and the DOE/PSN Cooperative Cask Testing Program

    Creer, J.M.; McKinnon, M.A.; Collantes, C.E.

    1990-01-01

    To date, water pools, metal casks, horizontal concrete modules, and modular vaults have been used to store the major quantity of commercial light water reactor spent nuclear fuel. Recently, vertical concrete dry storage casks have received consideration for storage of spent nuclear fuel. This paper reviews the evolution of the development of selected vertical concrete dry storage casks and outlines a cooperative cask testing (heat transfer and shielding) program involving the US Department of Energy and Pacific Sierra Nuclear Associates. Others participating in the cooperative program are Pacific Northwest Laboratory; EG ampersand G Idaho, Inc.; Wisconsin Electric Power Company; and the Electric Power Research Institute. 28 refs., 14 figs

  20. Highly selective and reversible chemosensor for Pd(2+) detected by fluorescence, colorimetry, and test paper.

    Wang, Mian; Liu, Xiaomei; Lu, Huizhe; Wang, Hongmei; Qin, Zhaohai

    2015-01-21

    A "turn-on" fluorescent and colorimetric chemosensor (RBS) for Pd(2+) has been designed and synthesized through introduction of sulfur as a ligand atom to Rhodamine B. RBS exhibits high selectivity (freedom from the interference of Hg(2+ )in particular) and sensitivity toward Pd(2+) with a detection limit as low as 2.4 nM. RBS is also a reversible sensor, and it can be made into test paper to detect Pd(2+) in pure water. Compared to the chemosensors that introduced phosphorus to Rhodamine to detect Pd(2+), RBS can be synthesized more simply and economically.

  1. Motivational changes in response to blocked goals and foreshortened time: testing alternatives to socioemotional selectivity theory.

    Fung, Helene H; Carstensen, Laura L

    2004-03-01

    Socioemotional selectivity theory contends that when people perceive time as limited, they prioritize emotionally meaningful goals. Although empirical support for the theory has been found in several studies, 2 alternative explanations for the pattern of findings remain: (a) emotional goals are pursued by default because nonemotional goals are blocked, and (b) emotional goals are pursued in search of emotional support rather than emotional meaning. This study tested these alternatives by examining social goals in response to blocked goals and foreshortened time. Findings reveal distinct motivational patterns, as reflected in social preferences and self-reported social goals, in response to the 2 types of constraints.

  2. Selected Examples of LDRD Projects Supporting Test Ban Treaty Verification and Nonproliferation

    Jackson, K. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Al-Ayat, R. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Walter, W. R. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States)

    2015-02-23

    The Laboratory Directed Research and Development (LDRD) Program at the DOE National Laboratories was established to ensure the scientific and technical vitality of these institutions and to enhance the their ability to respond to evolving missions and anticipate national needs. LDRD allows the Laboratory directors to invest a percentage of their total annual budget in cutting-edge research and development projects within their mission areas. We highlight a selected set of LDRD-funded projects, in chronological order, that have helped provide capabilities, people and infrastructure that contributed greatly to our ability to respond to technical challenges in support of test ban treaty verification and nonproliferation.

  3. Results of radiation tests at cryogenic temperature on some selected organic materials for the LHC

    Tavlet, M.; Schoenbacher, H.

    1999-01-01

    In the near future, particle accelerators and detectors as well as fusion reactors will operate at cryogenic temperatures. At temperatures as low as 2 K, the organic materials used for the insulation of the superconducting magnets and cables will be exposed to high radiation levels. In this work, a representative selection of organic materials comprising insulating films, cable insulations and epoxy-type-impregnated resins were exposed to neutron and gamma radiation of nuclear reactors, both at ambient and cryogenic temperatures, and were subsequently mechanically tested. The results show that the radiation degradation is never worse in a cryogenic fluid than it is in usual ambient conditions. (author)

  4. Pilot study risk assessment for selected problems at the Nevada Test Site (NTS)

    Daniels, J.I.; Andricevic, R.; Jacobson, R.L.

    1993-06-01

    The Nevada Test Site (NTS) is located in southwestern Nevada, about 105 km (65 mi) northwest of the city of Las Vegas. A series of tests was conducted in the late 1950s and early 1960s at or near the NTS to study issues involving plutonium-bearing devices. These tests resulted in the dispersal of about 5 TBq of 239,24O Pu on the surficial soils at the test locations. Additionally, underground tests of nuclear weapons devices have been conducted at the NTS since late 1962; ground water beneath the NTS has been contaminated with radionuclides produced by these tests. These two important problems have been selected for assessment. Regarding the plutonium contamination, because the residual 239 Pu decays slowly (half-life of 24,110 y), these sites could represent a long-term hazard if they are not remediated and if institutional controls are lost. To investigate the magnitude of the potential health risks for this no-remediation case, three basic exposure scenarios were defined that could bring individuals in contact with 239,24O Pu at the sites: (1) a resident living in a subdivision, (2) a resident farmer, and (3) a worker at a commercial facility -- all located at a test site. The predicted cancer risks for the resident farmer were more than a factor of three times higher than the suburban resident at the median risk level, and about a factor of ten greater than the reference worker at a commercial facility. At 100 y from the present, the 5, 50, and 95th percentile risks for the resident farmer at the most contaminated site were 4 x 10 -6 , 6 x 10 -5 , and 5 x 10 -4 , respectively. For the assessment of Pu in surface soil, the principal sources of uncertainty in the estimated risks were population mobility, the relationship between indoor and outdoor contaminant levels, and the dose and risk factors for bone, liver, and lung

  5. Features of application of test techniques in selection and certification of personnel

    Levina E.V.

    2017-04-01

    Full Text Available this article investigates the problem of use of test techniques in the course of selection and certification of personnel, and also for detection of features of formation of social and psychological climate in small groups and labor collectives. The group dynamics including individual preferences of players in the choice of strategy of behavior in a conflict situation in definition of the most acceptable social role, in identification of the most constructive and effective type of the administrative decision has the special importance. The author of the article offers a set of the test methods allowing to define social and psychological type of the individual at a stage of staff recruitment and to reveal its individual behavioral preferences that can structurally influence on team work.

  6. Competency test for selecting majors to produce competitive vocational graduates in industry

    Jiwa Permana Agus Aan

    2018-01-01

    Full Text Available President of Indonesia, Jokowi reoriented vocational school graduate toward demand driven graduates that is graduates who have certificate and skill required by industry. The initial stage of the new student on vocational school is choosing a major. At first step, students often confuse in choosing the majors they want. The mistake of choosing a department will be a set beck to the motivation of learning and skill, later will impade students future career. Thus competence test is needed to helping them in choosing the majors according to their competence. The solution to this problem is to conduct online competency tests for new students. The Results of research with 60 responden, 78% corresponds stated that the majors they were in match with their interests. Then the remaining 22% did not match. But the result of the competency assessment of students in match with the majors of is 40% and 60% of students need counseling for selection majors.

  7. Five-Level Active-Neutral-Point-Clamped DC/DC Converter for Medium-Voltage DC Grids

    Liu, Dong; Deng, Fujin; Chen, Zhe

    2017-01-01

    This paper proposes a five-level active-neutralpoint- clamped (5L-ANPC) dc/dc converter for applications in medium voltage dc (MVDC) grids. A modulation strategy is proposed for the 5L-ANPC dc/dc converter to generate multilevel voltage waveforms, which can effectively reduce voltage change rate dv...... effectively eliminate high voltage leaps caused by the dead time effect. In addition, a capacitor voltage control strategy is proposed for the 5L-ANPC dc/dc converter to ensure the balanced flying capacitor voltage and desired five-level voltage waveforms. Finally, simulation and experimental studies...

  8. Testing the Law of One Price under Nonlinearity for Egg Market of Selected Provinces of Iran

    M. Ghahremanzadeh

    2016-05-01

    Full Text Available Introduction: Regarding to the ever-increasing consumption of egg and consequently enhancement of its production during recent years, consideration to this output's market integration has special importance. Considering the fact that information on market integration may provide specific evidence as to the competitiveness of market, the effectiveness of arbitrage and the efficiency of pricing could be, likewise, useful to guide subsequent interventions aimed at improving the performance of market. In this context, in present study, validity of Law of One Price (LOP will be tested in the egg market and among selected provinces. Materials and Methods: Nonlinearity naturally extracted from local market due to existence of transportation and other transaction costs, so common cointegration test results are not suitable for market integration. In this study, at first, for being sure that series follow nonlinear behavior, Luukkonen et al. (1988 and BDS nonlinearity tests were used. Then for testing Law of One price in the egg market, nonlinear unit root test proposed by Emmanouilides and Fousekis (2012, which is an auxiliary regression for ESTAR model, was used. The data are daily retail prices of egg with the sample period ranging from April 2006 to march 2014 for north-west provinces of Iran including West Azerbaijan, East Azerbaijan, Ardebil, Tehran and Zanjan, which were obtained from State Live Stock Affairs Logistics Incorporated Company. Results and Discussion: Based on the DF-GLS unit root test, the null hypothesis of unit root for egg price differentials was rejected. So, all series of price differentials are stationary. In the next step nonlinearity of price differentials of egg between two provinces was examined. In BDS test, at the beginning, an ARMA model was estimated then the test was carried out to the residual of estimated model with embedding dimension (m 2-8 and the dimensional distance (ε chosen equals to 0.5 and 2 times of

  9. Radiation tests at cryogenic temperature on selected organic materials for LHC

    Humer, K.; Weber, H.W.; Szeless, B.; Tavlet, M.

    1997-01-01

    Future multi-TeV particle accelerators like the CERN Large Hadron Collider (LHC) will use superconducting magnets in which organic materials will be exposed to high radiation levels at temperatures as low as 2 K. A representative selection of organic materials comprising insulating films, cable insulations, epoxy resins and composites were exposed to neutron and gamma radiation of a nuclear reactor. Depending on the type of materials, the integrated radiation doses varied between 180 kGy and 155 MGy. During irradiation, the samples were kept close to the boiling temperature of liquid nitrogen, i.e. at 80 K, and thereafter stored in liquid nitrogen and transferred at the same temperature into the testing device for measurement of tensile and flexural strength. Tests were carried out on the same materials at similar dose rates at room temperature, and the results are compared with the ones obtained at cryogenic temperature. They show that within the selected dose range, a number of organic materials are suitable for use in radiation fields of the LHC at cryogenic temperature

  10. Results of radiation tests at cryogenic temperature on some selected organic materials for the LHC

    Schoenbacher, H.; Szeless, B.; Tavlet, M.; Humer, K.; Weber, H.W.

    1996-01-01

    Future multi-TeV particle accelerators like the CERN Large Hadron Collider (LHC) will use superconducting magnets where organic materials will be exposed to high radiation levels at temperatures as low as 2 K. A representative selection of organic materials comprising insulating films, cable insulations, and epoxy-type impregnated resins were exposed to neutron and gamma radiation of a nuclear reactor. Depending on the type of materials, the integrated radiation doses varied between 180 kGy and 155 MGy. During irradiation, the samples were kept close to the boiling temperature of liquid nitrogen i.e. ∼ 80 K and thereafter stored in liquid nitrogen and transferred at the same temperature into the testing device for measurement of tensile and flexural strength. Tests were carried out on the same materials at similar dose rates at room temperature, and the results were compared with those obtained at cryogenic temperature. They show that, within the selected dose range, a number of organic materials are suitable for use in the radiation field of the LHC at cryogenic temperature. (orig.)

  11. 75 FR 63040 - Airworthiness Directives; McDonnell Douglas Corporation Model DC-10-10, DC-10-10F, DC-10-30, DC...

    2010-10-14

    ... Airworthiness Directives; McDonnell Douglas Corporation Model DC- 10-10, DC-10-10F, DC-10-30, DC-10-30F (KDC-10... following new airworthiness directive (AD): 2010-21-13 McDonnell Douglas Corporation: Amendment 39-16473... November 18, 2010. Affected ADs (b) None. Applicability (c) This AD applies to McDonnell Douglas...

  12. 75 FR 68246 - Airworthiness Directives; McDonnell Douglas Corporation Model DC-10-10, DC-10-10F, DC-10-15, DC...

    2010-11-05

    ...-1044; Directorate Identifier 2010-NM-033-AD] RIN 2120-AA64 Airworthiness Directives; McDonnell Douglas..., 2007) and adding the following new AD: McDonnell Douglas Corporation: Docket No. FAA-2010-1044.... Applicability (c) This AD applies to all McDonnell Douglas Corporation Model DC-10-10, DC-10-10F, DC-10-15, DC...

  13. Results and Interpretation of the WFRD ELS Distillation Down-Select Test Data

    Delzeit, Lance Dean; Flynn, Michael; Carter, Layne; Long, David A.

    2010-01-01

    Testing of the Wiped-film Rotating-disk (WFRD) evaporator was conducted in support of the Exploration Life Support Distillation Down-Select Test. The WFRD was constructed at NASA Ames Research Center (ARC) and tested at NASA Marshall Space Flight Center (MSFC). The WFRD was delivered to MSFC in September 2009, and testing of solution #1 and solution #2 immediately following. Solution #1 was composed of humidity condensate and urine, including flush water and pretreatment chemicals. Solution #2 was composed of hygiene water, humidity condensate, and urine, including flush water and pretreatment chemicals. During the testing, the operational parameters of the WFRD were recorded and samples of the feed, brine, and product were collected and analyzed. The steady-state results of processing 414L of feed solution #1 and 1283L of feed solution #2 demonstrated that running the WFRD at a brine temperature of 50 C gave an average production rate of 16.7 L/hr. The specific energy consumption was 80.5W-hr/L. Data Analysis shows that the water recovery rates were 94% and 91%, respectively. The total mass of the WFRD as delivered to MSFC was 300 Kg. The volume of the tests stand rack was 1m width x 0.7m depth x 1.9m height or 1.5 cu m of which about half of the total volume is occupied by equipment. Chemical analysis of the distillate showed an average TOC of 20ppm, a pH of 3.5, and a conductivity of 98 mho/cm. The conductivity of the distillate, compared to the feed, decreased by 98.9%., the total ion concentration decreased by 99.6%, the total organics decreased 98.6%, and the metals were at or below detection limits

  14. Empirical tests of natural selection-based evolutionary accounts of ADHD: a systematic review.

    Thagaard, Marthe S; Faraone, Stephen V; Sonuga-Barke, Edmund J; Østergaard, Søren D

    2016-10-01

    ADHD is a prevalent and highly heritable mental disorder associated with significant impairment, morbidity and increased rates of mortality. This combination of high prevalence and high morbidity/mortality seen in ADHD and other mental disorders presents a challenge to natural selection-based models of human evolution. Several hypotheses have been proposed in an attempt to resolve this apparent paradox. The aim of this study was to review the evidence for these hypotheses. We conducted a systematic review of the literature on empirical investigations of natural selection-based evolutionary accounts for ADHD in adherence with the PRISMA guideline. The PubMed, Embase, and PsycINFO databases were screened for relevant publications, by combining search terms covering evolution/selection with search terms covering ADHD. The search identified 790 records. Of these, 15 full-text articles were assessed for eligibility, and three were included in the review. Two of these reported on the evolution of the seven-repeat allele of the ADHD-associated dopamine receptor D4 gene, and one reported on the results of a simulation study of the effect of suggested ADHD-traits on group survival. The authors of the three studies interpreted their findings as favouring the notion that ADHD-traits may have been associated with increased fitness during human evolution. However, we argue that none of the three studies really tap into the core symptoms of ADHD, and that their conclusions therefore lack validity for the disorder. This review indicates that the natural selection-based accounts of ADHD have not been subjected to empirical test and therefore remain hypothetical.

  15. Development of a smart DC grid model

    Dalimunthe, Amty Ma’rufah Ardhiyah; Mindara, Jajat Yuda; Panatarani, Camellia; Joni, I. Made, E-mail: imadejoni@phys.unpad.ac.id [Lab. of Instrumentation System and Functional Material Processing, Physics Department, Faculty of Mathematics and Natural Sciences, Padjadjaran University, Jl. Raya Bandung-Sumedang KM21, Jatinangor 45363, Jawa Barat (Indonesia)

    2016-03-11

    Smart grid and distributed generation should be the solution of the global climate change and the crisis energy of the main source of electrical power generation which is fossil fuel. In order to meet the rising electrical power demand and increasing service quality demands, as well as reduce pollution, the existing power grid infrastructure should be developed into a smart grid and distributed power generation which provide a great opportunity to address issues related to energy efficiency, energy security, power quality and aging infrastructure systems. The conventional of the existing distributed generation system is an AC grid while for a renewable resources requires a DC grid system. This paper explores the model of smart DC grid by introducing a model of smart DC grid with the stable power generation give a minimal and compressed circuitry that can be implemented very cost-effectively with simple components. The PC based application software for controlling was developed to show the condition of the grid and to control the grid become ‘smart’. The model is then subjected to a severe system perturbation, such as incremental change in loads to test the performance of the system again stability. It is concluded that the system able to detect and controlled the voltage stability which indicating the ability of power system to maintain steady voltage within permissible rangers in normal condition.

  16. Development of a smart DC grid model

    Dalimunthe, Amty Ma’rufah Ardhiyah; Mindara, Jajat Yuda; Panatarani, Camellia; Joni, I. Made

    2016-01-01

    Smart grid and distributed generation should be the solution of the global climate change and the crisis energy of the main source of electrical power generation which is fossil fuel. In order to meet the rising electrical power demand and increasing service quality demands, as well as reduce pollution, the existing power grid infrastructure should be developed into a smart grid and distributed power generation which provide a great opportunity to address issues related to energy efficiency, energy security, power quality and aging infrastructure systems. The conventional of the existing distributed generation system is an AC grid while for a renewable resources requires a DC grid system. This paper explores the model of smart DC grid by introducing a model of smart DC grid with the stable power generation give a minimal and compressed circuitry that can be implemented very cost-effectively with simple components. The PC based application software for controlling was developed to show the condition of the grid and to control the grid become ‘smart’. The model is then subjected to a severe system perturbation, such as incremental change in loads to test the performance of the system again stability. It is concluded that the system able to detect and controlled the voltage stability which indicating the ability of power system to maintain steady voltage within permissible rangers in normal condition.

  17. Pulsewidth modulated DC-to-DC power conversion circuits, dynamics, and control designs

    Choi, Byungcho

    2013-01-01

    This is the definitive reference for anyone involved in pulsewidth modulated DC-to-DC power conversion Pulsewidth Modulated DC-to-DC Power Conversion: Circuits, Dynamics, and Control Designs provides engineers, researchers, and students in the power electronics field with comprehensive and complete guidance to understanding pulsewidth modulated (PWM) DC-to-DC power converters. Presented in three parts, the book addresses the circuitry and operation of PWM DC-to-DC converters and their dynamic characteristics, along with in-depth discussions of control design of PWM DC-to

  18. Solar Photovoltaic DC Systems: Basics and Safety: Preprint

    McNutt, Peter F [National Renewable Energy Laboratory (NREL), Golden, CO (United States); Sekulic, William R [National Renewable Energy Laboratory (NREL), Golden, CO (United States); Dreifuerst, Gary [Lawrence Livermore National Laboratory - retired

    2018-04-02

    Solar Photovoltaic (PV) systems are common and growing with 42.4 GW installed capacity in U.S. (almost 15 GW added in 2016). This paper will help electrical workers, and emergency responders understand the basic operating principles and hazards of PV DC arrays. We briefly discuss the following aspects of solar photovoltaic (PV) DC systems: the effects of solar radiation and temperature on output power; PV module testing standards; common system configurations; a simple PV array sizing example; NEC guidelines and other safety features; DC array commissioning, periodic maintenance and testing; arc-flash hazard potential; how electrical workers and emergency responders can and do work safely around PV arrays; do moonlight and artificial lighting pose a real danger; typical safe operating procedures; and other potential DC-system hazards to be aware of. We also present some statistics on PV DC array electrical incidents and injuries. Safe PV array operation is possible with a good understanding of PV DC arrays basics and having good safe operating procedures in place.

  19. 75 FR 60602 - Airworthiness Directives; McDonnell Douglas Corporation Model DC-10-10, DC-10-10F, DC-10-15, DC...

    2010-10-01

    ... Airworthiness Directives; McDonnell Douglas Corporation Model DC- 10-10, DC-10-10F, DC-10-15, DC-10-30, DC-10... adding the following new AD: 2010-20-14 McDonnell Douglas Corporation: Amendment 39-16449. Docket No. FAA... the airplanes identified in paragraphs (c)(1) and (c)(2) of this AD. (1) McDonnell Douglas Corporation...

  20. 75 FR 6160 - Airworthiness Directives; McDonnell Douglas Corporation Model DC-10-10, DC-10-10F, DC-10-15, DC...

    2010-02-08

    ...-0032; Directorate Identifier 2009-NM-213-AD] RIN 2120-AA64 Airworthiness Directives; McDonnell Douglas...: McDonnell Douglas Corporation: Docket No. FAA-2010-0032; Directorate Identifier 2009-NM-213-AD. Comments Due... applies to McDonnell Douglas Corporation Model DC- 10-10, DC-10-10F, DC-10-15, DC-10-30, DC-10-30F (KC-10A...

  1. 75 FR 38943 - Airworthiness Directives; McDonnell Douglas Corporation Model DC-10-10, DC-10-10F, DC-10-30, DC...

    2010-07-07

    ...-0672; Directorate Identifier 2010-NM-047-AD] RIN 2120-AA64 Airworthiness Directives; McDonnell Douglas...: McDonnell Douglas Corporation: Docket No. FAA-2010-0672; Directorate Identifier 2010-NM-047-AD. Comments Due... applies to McDonnell Douglas Corporation Model DC- 10-10, DC-10-10F, DC-10-30, DC-10-30F (KDC-10), DC-10...

  2. Light-weight DC to very high voltage DC converter

    Druce, R.L.; Kirbie, H.C.; Newton, M.A.

    1998-06-30

    A DC-DC converter capable of generating outputs of 100 KV without a transformer comprises a silicon opening switch (SOS) diode connected to allow a charging current from a capacitor to flow into an inductor. When a specified amount of charge has flowed through the SOS diode, it opens up abruptly; and the consequential collapsing field of the inductor causes a voltage and current reversal that is steered into a load capacitor by an output diode. A switch across the series combination of the capacitor, inductor, and SOS diode closes to periodically reset the SOS diode by inducing a forward-biased current. 1 fig.

  3. Light-weight DC to very high voltage DC converter

    Druce, Robert L. (Union City, CA); Kirbie, Hugh C. (Dublin, CA); Newton, Mark A. (Livermore, CA)

    1998-01-01

    A DC-DC converter capable of generating outputs of 100 KV without a transformer comprises a silicon opening switch (SOS) diode connected to allow a charging current from a capacitor to flow into an inductor. When a specified amount of charge has flowed through the SOS diode, it opens up abruptly; and the consequential collapsing field of the inductor causes a voltage and current reversal that is steered into a load capacitor by an output diode. A switch across the series combination of the capacitor, inductor, and SOS diode closes to periodically reset the SOS diode by inducing a forward-biased current.

  4. Radiated electromagnetic emissions of DC-DC converters

    Feld, L; Jussen, R; Karpinski, W; Klein, K; Sammet, J; Wlochal, M

    2010-01-01

    For the CMS tracker at SLHC a new powering scheme is considered to be mandatory to allow the detector to provide at least the same performance as today at the LHC. The baseline solution of CMS foresees the use of DC-DC converters to provide larger currents with smaller losses. An important component of most converters are inductors which, however, tend to radiate the switching noise generated by the converter. The emissions of different inductors have been measured and simulated, the coil design has been optimized and noise susceptibility measurements, with present CMS hardware, have been performed. This article summarizes the results.

  5. Pulse-width modulated DC-DC power converters

    Kazimierczuk, Marian K

    2008-01-01

    This book studies switch-mode power supplies (SMPS) in great detail. This type of converter changes an unregulated DC voltage into a high-frequency pulse-width modulated (PWM) voltage controlled by varying the duty cycle, then changes the PWM AC voltage to a regulated DC voltage at a high efficiency by rectification and filtering. Used to supply electronic circuits, this converter saves energy and space in the overall system. With concept-orientated explanations, this book offers state-of-the-art SMPS technology and promotes an understanding of the principle operations of PWM converters,

  6. DESIGN OPTIMIZATION OF RESONANT DC-DC CONVERTERS

    Belqasem Aljafari

    2016-01-01

    Resonant DC/DC converters are the class of converters, which have L-C resonant tank serving as a major part of the power conversion process. The fundamental concept of the resonant converter is that the circulating energy in an L-C resonant circuit is manageable by changing the operating frequency, and therefore the converter can condition the input power to the desired output voltage. The development in power conversion technology is steady demand for high power efficiency and high power den...

  7. DC grid for home applications

    Elangovan, D.; Archana, R.; Jayadeep, V. J.; Nithin, M.; Arunkumar, G.

    2017-11-01

    More than fifty percent Indian population do not have access to electricity in daily lives. The distance between the power generating stations and the distribution centers forms one of the main reasons for lack of electrification in rural and remote areas. Here lies the importance of decentralization of power generation through renewable energy resources. In the present world, electricity is predominantly powered by alternating current, but most day to day devices like LED lamps, computers and electrical vehicles, all run on DC power. By directly supplying DC to these loads, the number of power conversion stages was reduced, and overall system efficiency increases. Replacing existing AC network with DC is a humongous task, but with power electronic techniques, this project intends to implement DC grid at a household level in remote and rural areas. Proposed work was designed and simulated successfully for various loads amounting to 250 W through appropriate power electronic convertors. Maximum utilization of the renewable sources for domestic and commercial application was achieved with the proposed DC topology.

  8. Linking DC together with TRSL

    Haxthausen, Anne; Yong, Xia

    1999-01-01

    In this talk we present a method for linking the Duration Calculus together with the Timed RAISE Specification Language. Duration Calculus (DC) [ZHR91] is an interval-based real time logic, which can be used naturally in capturing and eliciting users' real time requirements in the form of constra......In this talk we present a method for linking the Duration Calculus together with the Timed RAISE Specification Language. Duration Calculus (DC) [ZHR91] is an interval-based real time logic, which can be used naturally in capturing and eliciting users' real time requirements in the form.......TRSL is a real-time extension of the RAISE Specification Language (RSL) [Rlg92] which together with its associated method [Rmg95]and tools has shown to be very useful in the industrial development of software systems. Therefore, a promising approach for the development of real-time systemscould be to use DC...... for high-level specifications of real-time requirementsand TRSL for specifying real-time implementations in the form of timed communicating concurrent processes.In order to link DC and TRSL together in a well-founded way, we formally define what it means for a TRSL process to satisfy a DC requirement...

  9. 40 CFR 1051.310 - How must I select vehicles or engines for production-line testing?

    2010-07-01

    ... engines, randomly select and test one more engine. Then, calculate the required sample size for the model... distribution. σ = Test sample standard deviation (see paragraph (c)(2) of this section). x = Mean of emission... sample size for the model year as described in paragraph (c) of this section. (3) In the first test...

  10. Standard Guide for Selection of Test Methods for Interlayer Materials for Aerospace Transparent Enclosures

    American Society for Testing and Materials. Philadelphia

    2002-01-01

    1.1 This guide summarizes the standard test methods available for determining physical and mechanical characteristics of interlayer materials used in multi-ply aerospace transparent enclosures. 1.2 Interlayer materials are used to laminate glass-to-glass, glass-to-plastic, and plastic-to-plastic. Interlayer materials are basically transparent adhesives with high-quality optical properties. They can also serve as an energy absorbing medium, a fail-safe membrane to contain cockpit pressure and to prevent entry of impact debris; a strain insulator to accommodate different thermal expansion rates of members being laminated and as an adherent to prevent spalling of inner surface ply material fragments. The relative importance of an interlayer characteristic will be a function of the prime use it serves in its particular application. 1.3 This guide, as a summary of various methods in Section 2, is intended to facilitate the selection of tests that can be applied to interlayer materials. 1.4 The test methods list...

  11. Column Selection for Biomedical Analysis Supported by Column Classification Based on Four Test Parameters.

    Plenis, Alina; Rekowska, Natalia; Bączek, Tomasz

    2016-01-21

    This article focuses on correlating the column classification obtained from the method created at the Katholieke Universiteit Leuven (KUL), with the chromatographic resolution attained in biomedical separation. In the KUL system, each column is described with four parameters, which enables estimation of the FKUL value characterising similarity of those parameters to the selected reference stationary phase. Thus, a ranking list based on the FKUL value can be calculated for the chosen reference column, then correlated with the results of the column performance test. In this study, the column performance test was based on analysis of moclobemide and its two metabolites in human plasma by liquid chromatography (LC), using 18 columns. The comparative study was performed using traditional correlation of the FKUL values with the retention parameters of the analytes describing the column performance test. In order to deepen the comparative assessment of both data sets, factor analysis (FA) was also used. The obtained results indicated that the stationary phase classes, closely related according to the KUL method, yielded comparable separation for the target substances. Therefore, the column ranking system based on the FKUL-values could be considered supportive in the choice of the appropriate column for biomedical analysis.

  12. Procedure to select test organisms for environmental risk assessment of genetically modified crops in aquatic systems.

    Hilbeck, Angelika; Bundschuh, Rebecca; Bundschuh, Mirco; Hofmann, Frieder; Oehen, Bernadette; Otto, Mathias; Schulz, Ralf; Trtikova, Miluse

    2017-11-01

    For a long time, the environmental risk assessment (ERA) of genetically modified (GM) crops focused mainly on terrestrial ecosystems. This changed when it was scientifically established that aquatic ecosystems are exposed to GM crop residues that may negatively affect aquatic species. To assist the risk assessment process, we present a tool to identify ecologically relevant species usable in tiered testing prior to authorization or for biological monitoring in the field. The tool is derived from a selection procedure for terrestrial ecosystems with substantial but necessary changes to adequately consider the differences in the type of ecosystems. By using available information from the Water Framework Directive (2000/60/EC), the procedure can draw upon existing biological data on aquatic systems. The proposed procedure for aquatic ecosystems was tested for the first time during an expert workshop in 2013, using the cultivation of Bacillus thuringiensis (Bt) maize as the GM crop and 1 stream type as the receiving environment in the model system. During this workshop, species executing important ecological functions in aquatic environments were identified in a stepwise procedure according to predefined ecological criteria. By doing so, we demonstrated that the procedure is practicable with regard to its goal: From the initial long list of 141 potentially exposed aquatic species, 7 species and 1 genus were identified as the most suitable candidates for nontarget testing programs. Integr Environ Assess Manag 2017;13:974-979. © 2017 SETAC. © 2017 SETAC.

  13. Perception of basic tastes and threshold sensitivity during testing of selected judges

    Peter Zajác

    Full Text Available Normal 0 false false false SK JA X-NONE The sense of taste is one of the most important human senses. Alteration in taste perception can greately interfere to our lives, because it influences our dietary habits and consequently general human health. Many physiological and external factors can cause the loss of taste perception. These factors include for example certain diseases, the side effect of the use of certain medicaments, head trauma, gender, dietary habbits, smoking, role of saliva, age, stress and many more. In this paper we are discussing perception of basic tastes and treshold sensitivity during testing of selected groupe of 500 sensory judges. A resolution taste test and sensitivity treshold test were performed using basic tastes (sour, bitter, salty, sweet, umami, astringent, metallic. We have found that the perception of basic tastes decreese with human age. Smoking leads to significant errors in the determination of basic tastes. Different mistakes occures in different age categories. This study suggests further researches, investigating various factors influencing taste perception.  doi:10.5219/259

  14. Step-Up Partial Power DC-DC Converters for Two-Stage PV Systems with Interleaved Current Performance

    Jaime Wladimir Zapata

    2018-02-01

    Full Text Available This work presents a partial power converter allowing us to obtain, with a single DC-DC converter, the same feature as the classical interleaved operation of two converters. More precisely, the proposed topology performs similarly as the input-parallel output-series (IPOS configuration reducing the current ripple at the input of the system and dividing the individual converters power rating, compared to a single converter. The proposed topology consists of a partial DC-DC converter processing only a fraction of the total power, thus allowing high efficiency. Experimental results are provided to validate the proposed converter topology with a Flyback-based 100 W test bench with a transformer turns ratio n 1 = n 2 . Experimental results show high performances reducing the input current ripple around 30 % , further increasing the conversion efficiency.

  15. Implementation and flight tests for the Digital Integrated Automatic Landing System (DIALS). Part 1: Flight software equations, flight test description and selected flight test data

    Hueschen, R. M.

    1986-01-01

    Five flight tests of the Digital Automated Landing System (DIALS) were conducted on the Advanced Transport Operating Systems (ATOPS) Transportation Research Vehicle (TSRV) -- a modified Boeing 737 aircraft for advanced controls and displays research. These flight tests were conducted at NASA's Wallops Flight Center using the microwave landing system (MLS) installation on runway 22. This report describes the flight software equations of the DIALS which was designed using modern control theory direct-digital design methods and employed a constant gain Kalman filter. Selected flight test performance data is presented for localizer (runway centerline) capture and track at various intercept angles, for glideslope capture and track of 3, 4.5, and 5 degree glideslopes, for the decrab maneuver, and for the flare maneuver. Data is also presented to illustrate the system performance in the presence of cross, gust, and shear winds. The mean and standard deviation of the peak position errors for localizer capture were, respectively, 24 feet and 26 feet. For mild wind conditions, glideslope and localizer tracking position errors did not exceed, respectively, 5 and 20 feet. For gusty wind conditions (8 to 10 knots), these errors were, respectively, 10 and 30 feet. Ten hands off automatic lands were performed. The standard deviation of the touchdown position and velocity errors from the mean values were, respectively, 244 feet and 0.7 feet/sec.

  16. The 25 kW resonant dc/dc power converter

    Robson, R. R.

    1983-01-01

    The feasibility of processing 25-kW of power with a single, transistorized, series resonant converter stage was demonstrated by the successful design, development, fabrication, and testing of such a device which employs four Westinghouse D7ST transistors in a full-bridge configuration and operates from a 250-to-350 Vdc input bus. The unit has an overall worst-case efficiency of 93.5% at its full rated output of 1000 V and 25 A dc. A solid-state dc input circuit breaker and output-transient-current limiters are included in and integrated into the design. Full circuit details of the converter are presented along with the test data.

  17. Pilot study risk assessment for selected problems at the Nevada Test Site (NTS)

    Daniels, J.I. [ed.; Anspaugh, L.R.; Bogen, K.T.; Daniels, J.I.; Layton, D.W.; Straume, T. [Lawrence Livermore National Lab., CA (United States); Andricevic, R.; Jacobson, R.L. [Nevada Univ., Las Vegas, NV (United States). Water Resources Center; Meinhold, A.F.; Holtzman, S.; Morris, S.C.; Hamilton, L.D. [Brookhaven National Lab., Upton, NY (United States)

    1993-06-01

    The Nevada Test Site (NTS) is located in southwestern Nevada, about 105 km (65 mi) northwest of the city of Las Vegas. A series of tests was conducted in the late 1950s and early 1960s at or near the NTS to study issues involving plutonium-bearing devices. These tests resulted in the dispersal of about 5 TBq of {sup 239,24O}Pu on the surficial soils at the test locations. Additionally, underground tests of nuclear weapons devices have been conducted at the NTS since late 1962; ground water beneath the NTS has been contaminated with radionuclides produced by these tests. These two important problems have been selected for assessment. Regarding the plutonium contamination, because the residual {sup 239}Pu decays slowly (half-life of 24,110 y), these sites could represent a long-term hazard if they are not remediated and if institutional controls are lost. To investigate the magnitude of the potential health risks for this no-remediation case, three basic exposure scenarios were defined that could bring individuals in contact with {sup 239,24O}Pu at the sites: (1) a resident living in a subdivision, (2) a resident farmer, and (3) a worker at a commercial facility -- all located at a test site. The predicted cancer risks for the resident farmer were more than a factor of three times higher than the suburban resident at the median risk level, and about a factor of ten greater than the reference worker at a commercial facility. At 100 y from the present, the 5, 50, and 95th percentile risks for the resident farmer at the most contaminated site were 4 x 10{sup {minus}6}, 6 x 10{sup {minus}5}, and 5 x 10{sup {minus}4}, respectively. For the assessment of Pu in surface soil, the principal sources of uncertainty in the estimated risks were population mobility, the relationship between indoor and outdoor contaminant levels, and the dose and risk factors for bone, liver, and lung.

  18. Pilot study risk assessment for selected problems at the Nevada Test Site (NTS)

    Daniels, J.I. (ed.)

    1993-06-01

    The Nevada Test Site (NTS) is located in southwestern Nevada, about 105 km (65 mi) northwest of the city of Las Vegas. A series of tests was conducted in the late 1950s and early 1960s at or near the NTS to study issues involving plutonium-bearing devices. These tests resulted in the dispersal of about 5 TBq of [sup 239,24O]Pu on the surficial soils at the test locations. Additionally, underground tests of nuclear weapons devices have been conducted at the NTS since late 1962; ground water beneath the NTS has been contaminated with radionuclides produced by these tests. These two important problems have been selected for assessment. Regarding the plutonium contamination, because the residual [sup 239]Pu decays slowly (half-life of 24,110 y), these sites could represent a long-term hazard if they are not remediated and if institutional controls are lost. To investigate the magnitude of the potential health risks for this no-remediation case, three basic exposure scenarios were defined that could bring individuals in contact with [sup 239,24O]Pu at the sites: (1) a resident living in a subdivision, (2) a resident farmer, and (3) a worker at a commercial facility -- all located at a test site. The predicted cancer risks for the resident farmer were more than a factor of three times higher than the suburban resident at the median risk level, and about a factor of ten greater than the reference worker at a commercial facility. At 100 y from the present, the 5, 50, and 95th percentile risks for the resident farmer at the most contaminated site were 4 x 10[sup [minus]6], 6 x 10[sup [minus]5], and 5 x 10[sup [minus]4], respectively. For the assessment of Pu in surface soil, the principal sources of uncertainty in the estimated risks were population mobility, the relationship between indoor and outdoor contaminant levels, and the dose and risk factors for bone, liver, and lung.

  19. A test of phenotypic selection on petal form in the wild carnation, Dianthus inoxianus.

    Herrera, J; Balao, F

    2015-11-01

    Floral phenotypes are considered a product of pollinator-mediated selection, which also has the side effect of decreasing floral variation within species. Correlates of flower visibility and function were studied in a carnation species (Dianthus inoxianus), which has crepuscular anthesis and scent-based pollination by the hawkmoth Hyles livornica. We also assessed constancy of flower form in nature and in cultivation and, using fruit set as an estimate of plant relative fitness, tested whether the main pollinator exerted phenotypic selection on floral traits. Petal claw, which is roughly equivalent to the average depth at which an insect's proboscis must be inserted to reach nectar, was remarkably constant among wild plants (coefficient of variation 8%). In contrast, the area of the visible part of the petal, and the intensity of a coloured dot pattern on the petal was very variable (respectively CV = 34% and 102%). Cultivation in a common environment revealed significant variation among genotypes as regards petal area, degree of laciniation and extension of the dot pattern, but not petal claw length, which remained steady. Petal area, shape and colour did not affect relative fitness during the year of study, but plants with intermediate petal claws (i.e. floral tubes) set significantly more fruit. Results are compatible with low response of the main pollinator to variation in visual traits (petal area, laciniation, colour) and high responsiveness to variation in other aspects (tube length). Inconsistent phenotypic selection by pollinators may add to other causes of floral variation in the genus Dianthus, the causes of which are discussed. © 2015 German Botanical Society and The Royal Botanical Society of the Netherlands.

  20. Neuropsychological Test Selection for Cognitive Impairment Classification: A Machine Learning Approach

    Williams, Jennifer A.; Schmitter-Edgecombe, Maureen; Cook, Diane J.

    2016-01-01

    Introduction Reducing the amount of testing required to accurately detect cognitive impairment is clinically relevant. The aim of this research was to determine the fewest number of clinical measures required to accurately classify participants as healthy older adult, mild cognitive impairment (MCI) or dementia using a suite of classification techniques. Methods Two variable selection machine learning models (i.e., naive Bayes, decision tree), a logistic regression, and two participant datasets (i.e., clinical diagnosis, clinical dementia rating; CDR) were explored. Participants classified using clinical diagnosis criteria included 52 individuals with dementia, 97 with MCI, and 161 cognitively healthy older adults. Participants classified using CDR included 154 individuals CDR = 0, 93 individuals with CDR = 0.5, and 25 individuals with CDR = 1.0+. Twenty-seven demographic, psychological, and neuropsychological variables were available for variable selection. Results No significant difference was observed between naive Bayes, decision tree, and logistic regression models for classification of both clinical diagnosis and CDR datasets. Participant classification (70.0 – 99.1%), geometric mean (60.9 – 98.1%), sensitivity (44.2 – 100%), and specificity (52.7 – 100%) were generally satisfactory. Unsurprisingly, the MCI/CDR = 0.5 participant group was the most challenging to classify. Through variable selection only 2 – 9 variables were required for classification and varied between datasets in a clinically meaningful way. Conclusions The current study results reveal that machine learning techniques can accurately classifying cognitive impairment and reduce the number of measures required for diagnosis. PMID:26332171

  1. The Free and Cued Selective Reminding Test: evidence of psychometric adequacy

    KATJA OCEPEK-WELIKSON

    2009-09-01

    Full Text Available These analyses examine the psychometric properties of the Free and Cued Selective Reminding Test with Immediate Recall (FCSRT-IR. FCSRT-IR is a measure of memory under conditions that control attention and cognitive processing in order to obtain an assessment of memory unconfounded by normal agerelated changes in cognition. FCSRT-IR performance has been associated with preclinical and early dementia in several longitudinal epidemiological studies. Factor and item response theory analyses were applied to FCSRT-IR data from patients at a geriatric primary care center who had independently established clinical diagnoses. The results provide supporting evidence for the psychometric adequacy of the FCSR-IR in terms of reliability, essential (sufficient unidimensionality, information across the continuum of memory disability/ability, and classification accuracy. The psychometric adequacy of the FCSRT-IR adds further validity to its use as a case finding strategy for dementia.

  2. Age and motives for volunteering: testing hypotheses derived from socioemotional selectivity theory.

    Okun, Morris A; Schultz, Amy

    2003-06-01

    Following a meta-analysis of the relations between age and volunteer motives (career, understanding, enhancement, protective, making friends, social, and values), the authors tested hypotheses derived from socioemotional selectivity theory regarding the effects of age on these volunteer motives. The Volunteer Functions Inventory was completed by 523 volunteers from 2 affiliates of the International Habitat for Humanity. Multiple regression analyses revealed, as predicted, that as age increases, career and understanding volunteer motivation decrease and social volunteer motivation increases. Contrary to expectations, age did not contribute to the prediction of enhancement, protective, and values volunteer motivations and the relation between age and making friends volunteer motivation was nonlinear. The results were discussed in the context of age-differential and age-similarity perspectives on volunteer motivation.

  3. Violent media exposure, aggression and CU traits in adolescence: Testing the selection and socialization hypotheses.

    Rydell, Ann-Margret

    2016-10-01

    We investigated the role of exposure to violent action for later aggression and for later callous-unemotional traits in a sample of Swedish adolescents (N = 77-85), testing the selection and socialization hypotheses. Adolescents reported on violent delinquency and on callous-unemotional (CU) traits at age 15, on their media habits at age 16 and on reactive and proactive aggression and CU traits at age 18. The socialization hypothesis was supported with regard to aggression, that is, violent delinquency did not affect consumption of violent action, but controlling for violent delinquency, consumption of violent action added to proactive aggression and, marginally, to reactive aggression. The selection hypothesis was supported with regard to CU traits, that is, high levels of CU traits predicted frequent consumption of violent action, but consumption of violent action did not affect later levels of CU traits. Frequent violent media use was associated with later aggression. The associations between CU traits and violent media need further study. Copyright © 2016 The Foundation for Professionals in Services for Adolescents. Published by Elsevier Ltd. All rights reserved.

  4. State test-anxiety, selective attention and concentration in university students.

    Fernández-Castillo, Antonio; Caurcel, María J

    2015-08-01

    The principal aim of this study was to assess the level of selective attention and mental concentration before exams in a sample of university students and to determine a possible relationship between anxiety and reduction of levels of attention in this circumstance. A total of 403 university students, 176 men and 227 women, aged from 18 to 46 years, participated in the study. Of them, 169 were first-year undergraduates, 118 were second to fourth-year undergraduates and 116 were postgraduate Master's degree students. All of them completed the Spanish version of the Spielberger State-Anxiety Inventory and the D2 Attention Test just before taking an exam. Our results showed that participants with lower levels of anxiety had higher levels of selective attention and mental concentration before the exam. These results specifically indicate that when anxiety levels are very high, this could over-activate the orientating and alerting functions and to reduce the capacity of attentional control. These processes could have a negative impact on specific attentional processes and become a negative influence on performance in exams. © 2014 International Union of Psychological Science.

  5. An Improved Droop Control Method for DC Microgrids Based on Low Bandwidth Communication with DC Bus Voltage Restoration and Enhanced Current Sharing Accuracy

    Lu, Xiaonan; Guerrero, Josep M.; Sun, Kai

    2014-01-01

    Droop control is the basic control method for load current sharing in dc microgrid applications. The conventional dc droop control method is realized by linearly reducing the dc output voltage as the output current increases. This method has two limitations. First, with the consideration of line...... resistance in a droop-controlled dc microgrid, since the output voltage of each converter cannot be exactly the same, the output current sharing accuracy is degraded. Second, the DC bus voltage deviation increases with the load due to the droop action. In this paper, in order to improve the performance......, and the LBC system is only used for changing the values of the dc voltage and current. Hence, a decentralized control scheme is accomplished. The simulation test based on Matlab/Simulink and the experimental validation based on a 2×2.2 kW prototype were implemented to demonstrate the proposed approach....

  6. Process of DC-SC photoinjector

    Xiang Rong; Zhao Kui; Quan Shengwen; Ding Yuantao; Zhang Baocheng; Lu Xiangyang; Lin Lin; Wang Lifang; Chen Jiaer

    2004-01-01

    The DC-SC photoinjector at Beijing University is designed to provide an electron beam of average current 1 mA with the energy of 2-3 MeV and normalized rms transverse emittance of 3πmm-mrad at an 81.25 MHz repetition rate. The test facility has been completely installed in our lab. In this paper some of the ongoing experimental activities are summarized. First results from the cold test of superconducting cavity have been presented. According to the results, authors have improved the main coupler to repress the multipacting. The beam test of 100 μA on the DC gun has been done, photocathode preparation chamber can produce Cs 2 Te cathodes, and the laser system can provide laser pulse with 266 nm wavelength. The time synchronization between laser and RF power has been achieved by a timing stabilizer. A new method using 'due image pattern' of Cherenkov radiation will be commissioned to measure beam emittance. The next step is under way, to prepare all the equipment for the beam tests. (authors)

  7. Test Population Selection from Weibull-Based, Monte Carlo Simulations of Fatigue Life

    Vlcek, Brian L.; Zaretsky, Erwin V.; Hendricks, Robert C.

    2012-01-01

    Fatigue life is probabilistic and not deterministic. Experimentally establishing the fatigue life of materials, components, and systems is both time consuming and costly. As a result, conclusions regarding fatigue life are often inferred from a statistically insufficient number of physical tests. A proposed methodology for comparing life results as a function of variability due to Weibull parameters, variability between successive trials, and variability due to size of the experimental population is presented. Using Monte Carlo simulation of randomly selected lives from a large Weibull distribution, the variation in the L10 fatigue life of aluminum alloy AL6061 rotating rod fatigue tests was determined as a function of population size. These results were compared to the L10 fatigue lives of small (10 each) populations from AL2024, AL7075 and AL6061. For aluminum alloy AL6061, a simple algebraic relationship was established for the upper and lower L10 fatigue life limits as a function of the number of specimens failed. For most engineering applications where less than 30 percent variability can be tolerated in the maximum and minimum values, at least 30 to 35 test samples are necessary. The variability of test results based on small sample sizes can be greater than actual differences, if any, that exists between materials and can result in erroneous conclusions. The fatigue life of AL2024 is statistically longer than AL6061 and AL7075. However, there is no statistical difference between the fatigue lives of AL6061 and AL7075 even though AL7075 had a fatigue life 30 percent greater than AL6061.

  8. Modeling and analysis of fractional order DC-DC converter.

    Radwan, Ahmed G; Emira, Ahmed A; AbdelAty, Amr M; Azar, Ahmad Taher

    2017-07-11

    Due to the non-idealities of commercial inductors, the demand for a better model that accurately describe their dynamic response is elevated. So, the fractional order models of Buck, Boost and Buck-Boost DC-DC converters are presented in this paper. The detailed analysis is made for the two most common modes of converter operation: Continuous Conduction Mode (CCM) and Discontinuous Conduction Mode (DCM). Closed form time domain expressions are derived for inductor currents, voltage gain, average current, conduction time and power efficiency where the effect of the fractional order inductor is found to be strongly present. For example, the peak inductor current at steady state increases with decreasing the inductor order. Advanced Design Systems (ADS) circuit simulations are used to verify the derived formulas, where the fractional order inductor is simulated using Valsa Constant Phase Element (CPE) approximation and Generalized Impedance Converter (GIC). Different simulation results are introduced with good matching to the theoretical formulas for the three DC-DC converter topologies under different fractional orders. A comprehensive comparison with the recently published literature is presented to show the advantages and disadvantages of each approach. Copyright © 2017 ISA. Published by Elsevier Ltd. All rights reserved.

  9. An Integrated Multifunctional Bidirectional AC/DC and DC/DC Converter for Electric Vehicles Applications

    Liwen Pan

    2016-06-01

    Full Text Available This paper presents an on-board vehicular battery charger that integrates bidirectional AC/DC converter and DC/DC converter to achieve high power density for application in electric vehicles (EVs. The integrated charger is able to transfer electrical energy between the battery pack and the electric traction system and to function as an AC/DC battery charger. The integrated charger topology is presented and the design of passive components is discussed. The control schemes are developed for motor drive system and battery-charging system with a power pulsation reduction circuit. Simulation results in MATLAB/Simulink and experiments on a 30-kW motor drive and 3.3-kW AC/DC charging prototype validate the performance of the proposed technology. In addition, power losses, efficiency comparison and thermal stress for the integrated charger are illustrated. The results of the analyses show the validity of the advanced integrated charger for electric vehicles.

  10. Switching coordination of distributed dc-dc converters for highly efficient photovoltaic power plants

    Agamy, Mohammed; Elasser, Ahmed; Sabate, Juan Antonio; Galbraith, Anthony William; Harfman Todorovic, Maja

    2014-09-09

    A distributed photovoltaic (PV) power plant includes a plurality of distributed dc-dc converters. The dc-dc converters are configured to switch in coordination with one another such that at least one dc-dc converter transfers power to a common dc-bus based upon the total system power available from one or more corresponding strings of PV modules. Due to the coordinated switching of the dc-dc converters, each dc-dc converter transferring power to the common dc-bus continues to operate within its optimal efficiency range as well as to optimize the maximum power point tracking in order to increase the energy yield of the PV power plant.

  11. Stroop Color-Word Test: A Screening Measure of Selective Attention to Differentiate LD From Non LD Children.

    Lazarus, Philip J.; And Others

    1984-01-01

    Used the Stroop Color-Word Test to measure selective attention in learning disabled (N=45) and nonLD (N=50) children. Results indicated that LD children have a significant weakness in the process of selective attention compared to the nonLD children. Findings suggested that the Stroop is an effective screening measure. (JAC)

  12. Application of Distributed DC/DC Electronics in Photovoltaic Systems

    Kabala, Michael

    In a typical residential, commercial or utility grade photovoltaic (PV) system, PV modules are connected in series and in parallel to form an array that is connected to a standard DC/AC inverter, which is then connected directly to the grid. This type of standard installation; however, does very little to maximize the energy output of the solar array if certain conditions exist. These conditions could include age, temperature, irradiance and other factors that can cause mismatch between PV modules in an array that severely cripple the output power of the system. Since PV modules are typically connected in series to form a string, the output of the entire string is limited by the efficiency of the weakest module. With PV module efficiencies already relatively low, it is critical to extract the maximum power out of each module in order to make solar energy an economically viable competitor to oil and gas. Module level DC/DC electronics with maximum power point (MPP) tracking solves this issue by decoupling each module from the string in order for the module to operate independently of the geometry and complexity of the surrounding system. This allows each PV module to work at its maximum power point by transferring the maximum power the module is able to deliver directly to the load by either boosting (stepping up) the voltage or bucking (stepping down) the voltage. The goal of this thesis is to discuss the development of a per-module DC/DC converter in order to maximize the energy output of a PV module and reduce the overall cost of the system by increasing the energy harvest.

  13. Assessing group differences in biodiversity by simultaneously testing a user-defined selection of diversity indices.

    Pallmann, Philip; Schaarschmidt, Frank; Hothorn, Ludwig A; Fischer, Christiane; Nacke, Heiko; Priesnitz, Kai U; Schork, Nicholas J

    2012-11-01

    Comparing diversities between groups is a task biologists are frequently faced with, for example in ecological field trials or when dealing with metagenomics data. However, researchers often waver about which measure of diversity to choose as there is a multitude of approaches available. As Jost (2008, Molecular Ecology, 17, 4015) has pointed out, widely used measures such as the Shannon or Simpson index have undesirable properties which make them hard to compare and interpret. Many of the problems associated with the use of these 'raw' indices can be corrected by transforming them into 'true' diversity measures. We introduce a technique that allows the comparison of two or more groups of observations and simultaneously tests a user-defined selection of a number of 'true' diversity measures. This procedure yields multiplicity-adjusted P-values according to the method of Westfall and Young (1993, Resampling-Based Multiple Testing: Examples and Methods for p-Value Adjustment, 49, 941), which ensures that the rate of false positives (type I error) does not rise when the number of groups and/or diversity indices is extended. Software is available in the R package 'simboot'. © 2012 Blackwell Publishing Ltd.

  14. Selection of a leaching test method for waste product conformity verification

    Lopes, Isabel Sofia R.F.S.; Tello, Clédola Cássia O.; Haucz, Maria Judite A., E-mail: isabel.lopes@cdtn.br, E-mail: tellocc@cdtn.br, E-mail: hauczmj@cdtn.br [Centro de Desenvolvimento da Tecnologia Nuclear (CDTN/CNEN-MG), Belo Horizonte, MG (Brazil)

    2017-07-01

    A study on the waste acceptance criteria (WAC) for disposal in a near-surface repository is being implemented by CDTN / CNEN. The acceptance criteria are used to ensure the safety in the repository facility in order to protect the employees, the public and the environment from some possible harmful and dangerous effects of the ionizing radiation. A near-surface repository is intended to be built for disposal of the Brazilian low- and intermediate level wastes. Leaching was the criterion chosen to be studied in this research. It is extremely important for the safety assessment to evaluate the waste form in relation to the radionuclides release, to predict the repository performance in the long term. As in the Brazilian WAC the test to measure the radionuclides leaching is not defined yet, two leaching tests were selected to be performed, the ISO 6961 and the ASTM C1308. The results will be analyzed in order to verify their similarities and differences and also their advantages and disadvantages. Inactive tracers cesium and lead were used as tracers to follow the leaching in both procedures. (author)

  15. Selection of a leaching test method for waste product conformity verification

    Lopes, Isabel Sofia R.F.S.; Tello, Clédola Cássia O.; Haucz, Maria Judite A.

    2017-01-01

    A study on the waste acceptance criteria (WAC) for disposal in a near-surface repository is being implemented by CDTN / CNEN. The acceptance criteria are used to ensure the safety in the repository facility in order to protect the employees, the public and the environment from some possible harmful and dangerous effects of the ionizing radiation. A near-surface repository is intended to be built for disposal of the Brazilian low- and intermediate level wastes. Leaching was the criterion chosen to be studied in this research. It is extremely important for the safety assessment to evaluate the waste form in relation to the radionuclides release, to predict the repository performance in the long term. As in the Brazilian WAC the test to measure the radionuclides leaching is not defined yet, two leaching tests were selected to be performed, the ISO 6961 and the ASTM C1308. The results will be analyzed in order to verify their similarities and differences and also their advantages and disadvantages. Inactive tracers cesium and lead were used as tracers to follow the leaching in both procedures. (author)

  16. Selective attentional deficit in essential tremor: Evidence from the attention network test.

    Pauletti, Caterina; Mannarelli, Daniela; De Lucia, Maria Caterina; Locuratolo, Nicoletta; Currà, Antonio; Missori, Paolo; Marinelli, Lucio; Fattapposta, Francesco

    2015-11-01

    The traditional view of essential tremor (ET) as a monosymptomatic and benign disorder has been reconsidered after patients with ET have been shown to experience cognitive deficits that are also related to attention. The Attention Network Test (ANT) is a rapid, widely used test to measure the efficiency of three attentional networks, i.e. alerting, orienting and executive, by evaluating reaction times (RTs) in response to visual stimuli. The aim of this study was to investigate attentional functioning in ET patients by means of the ANT. 21 non-demented patients with ET and 21 age- and sex-matched healthy controls performed the ANT. RT was significantly longer in ET patients than in controls (p attention in ET patients, probably owing to a dysfunction in the cerebello-thalamo-cortical loop. These selective attentional deficits are not related to clinical motor symptoms, contributing to shed further light on the clinical picture of ET. Copyright © 2015 Elsevier Ltd. All rights reserved.

  17. DC systems design and research of Hainan Changjiang nuclear power plant

    Jiang Qingshui; Wang Yuhan

    2014-01-01

    Hainan Changjiang nuclear power plant is different from the referent power plant, the DC and 220 V AC uninterrupted systems of the nuclear island have been changed since the control system use DCS. It has different design on DC systems, power supply, selectivity of breakers, capacity of equipments and layout. We optimize the design of DC systems at the basement of Fuqing and Fangjiashan project. These are good experiments for the three generation nuclear power project about DC systems design of ACP1000. (authors)

  18. Drilling history core hole DC-6 Hanford, Washington

    1978-06-01

    Core hole DC-6 was completed in May 1978 by Boyles Brothers Drilling Company, Spokane, Washington, under subcontract to Fenix and Scisson, Inc. The hole was cored for the US Department of Energy and the Rockwell Hanford Operations' Basalt Waste Isolation Program. Fenix and Scisson, Inc. furnished the engineering, daily supervision of the core drilling activities, and geologic core logging for hole DC-6. Core hole DC-6 is located within the boundary of the Hanford Site at the old Hanford town site. The Hanford Site coordinates for DC-6 are North 54,127.17 feet and West 17,721.00 feet. The surface elevation is approximately 402 feet above sea level. The purpose of core hole DC-6 was to core drill vertically through the basalt and interbed units for stratigraphic depth determination and core collection and to provide a borehole for hydrologic testing. The total depth of core hole DC-6 was 4336 feet. Core recovery was 98.4% of the total footage cored

  19. Brushless dc motors. [applications in non-space technology

    1975-01-01

    Brushless dc motors were intensively developed and tested over several years before qualification as the prime movers for Apollo Spacecraft life support blowers, and for circulating oxygen in the lunar portable life support system. Knowledge gained through prototype development and critical testing has significantly influenced the technology employed, broadened markets and applications, and reduced the cost of present day motors.

  20. Experience from design, prototyping and production of a DC-DC conversion powering scheme for the CMS Phase-1 Pixel Upgrade

    AUTHOR|(CDS)2069786; Karpinski, Waclaw; Klein, Katja; Lipinski, Martin; Preuten, Marius; Rauch, Max Philip; Schmitz, Stefan Antonius; Wlochal, Michael

    2016-01-01

    The testing program is outlined, results from mass production are presented and issues that have been encountered are described. In addition, two system level challenges, namely the choice of output voltage in the presence of large, load-dependent voltage drops, and the thermal management required to remove the heat load caused by the DC-DC converters, are discussed.

  1. An objective approach for Burkholderia pseudomallei strain selection as challenge material for medical countermeasures efficacy testing

    Kristopher E. Van Zandt

    2012-09-01

    Full Text Available Burkholderia pseudomallei is the causative agent of melioidosis, a rare disease of biodefense concern with high mortality and extreme difficulty in treatment. No human vaccines are available that protect against B. pseudomallei infection, and with the current limitations of antibiotic treatment, the development of new preventative and therapeutic interventions is crucial. Although clinical trials could be used to test the efficacy of new medical countermeasures (MCMs, the high mortality rates associated with melioidosis raises significant ethical issues concerning treating individuals with new compounds with unknown efficacies. The US Food and Drug Administration (FDA has formulated a set of guidelines for the licensure of new MCMs to treat diseases in which it would be unethical to test the efficacy of these drugs in humans. The FDA Animal Rule 21 CFR 314 calls for consistent, well-characterized B. pseudomallei strains to be used as challenge material in animal models. In order to facilitate the efficacy testing of new MCMs for melioidosis using animal models, we intend to develop a well-characterized panel of strains for use. This panel will comprise of strains that were isolated from human cases, have a low passage history, are virulent in animal models, and are well characterized phenotypically and genotypically. We have reviewed published and unpublished data on various B. pseudomallei strains to establish an objective method for selecting the strains to be included in the panel of B. pseudomallei strains with attention to five categories: animal infection models, genetic characterization, clinical and passage history, and availability of the strain to the research community. We identified 109 strains with data in at least one of the five categories, scored each strain based on the gathered data and identified 6 strains as candidate for a B. pseudomallei strain panel.

  2. An objective approach for Burkholderia pseudomallei strain selection as challenge material for medical countermeasures efficacy testing.

    Van Zandt, Kristopher E; Tuanyok, Apichai; Keim, Paul S; Warren, Richard L; Gelhaus, H Carl

    2012-01-01

    Burkholderia pseudomallei is the causative agent of melioidosis, a rare disease of biodefense concern with high mortality and extreme difficulty in treatment. No human vaccines are available that protect against B. pseudomallei infection, and with the current limitations of antibiotic treatment, the development of new preventative and therapeutic interventions is crucial. Although clinical trials could be used to test the efficacy of new medical countermeasures (MCMs), the high mortality rates associated with melioidosis raises significant ethical issues concerning treating individuals with new compounds with unknown efficacies. The US Food and Drug Administration (FDA) has formulated a set of guidelines for the licensure of new MCMs to treat diseases in which it would be unethical to test the efficacy of these drugs in humans. The FDA "Animal Rule" 21 CFR 314 calls for consistent, well-characterized B. pseudomallei strains to be used as challenge material in animal models. In order to facilitate the efficacy testing of new MCMs for melioidosis using animal models, we intend to develop a well-characterized panel of strains for use. This panel will comprise of strains that were isolated from human cases, have a low passage history, are virulent in animal models, and are well-characterized phenotypically and genotypically. We have reviewed published and unpublished data on various B. pseudomallei strains to establish an objective method for selecting the strains to be included in the panel of B. pseudomallei strains with attention to five categories: animal infection models, genetic characterization, clinical and passage history, and availability of the strain to the research community. We identified 109 strains with data in at least one of the five categories, scored each strain based on the gathered data and identified six strains as candidate for a B. pseudomallei strain panel.

  3. Selection of potential probiotic lactic acid bacteria from fermented olives by in vitro tests.

    Argyri, Anthoula A; Zoumpopoulou, Georgia; Karatzas, Kimon-Andreas G; Tsakalidou, Effie; Nychas, George-John E; Panagou, Efstathios Z; Tassou, Chrysoula C

    2013-04-01

    The present study aims to evaluate the probiotic potential of lactic acid bacteria (LAB) isolated from naturally fermented olives and select candidates to be used as probiotic starters for the improvement of the traditional fermentation process and the production of newly added value functional foods. Seventy one (71) lactic acid bacterial strains (17 Leuconostoc mesenteroides, 1 Ln. pseudomesenteroides, 13 Lactobacillus plantarum, 37 Lb. pentosus, 1 Lb. paraplantarum, and 2 Lb. paracasei subsp. paracasei) isolated from table olives were screened for their probiotic potential. Lb. rhamnosus GG and Lb. casei Shirota were used as reference strains. The in vitro tests included survival in simulated gastrointestinal tract conditions, antimicrobial activity (against Listeria monocytogenes, Salmonella Enteritidis, Escherichia coli O157:H7), Caco-2 surface adhesion, resistance to 9 antibiotics and haemolytic activity. Three (3) Lb. pentosus, 4 Lb. plantarum and 2 Lb. paracasei subsp. paracasei strains demonstrated the highest final population (>8 log cfu/ml) after 3 h of exposure at low pH. The majority of the tested strains were resistant to bile salts even after 4 h of exposure, while 5 Lb. plantarum and 7 Lb. pentosus strains exhibited partial bile salt hydrolase activity. None of the strains inhibited the growth of the pathogens tested. Variable efficiency to adhere to Caco-2 cells was observed. This was the same regarding strains' susceptibility towards different antibiotics. None of the strains exhibited β-haemolytic activity. As a whole, 4 strains of Lb. pentosus, 3 strains of Lb. plantarum and 2 strains of Lb. paracasei subsp. paracasei were found to possess desirable in vitro probiotic properties similar to or even better than the reference probiotic strains Lb. casei Shirota and Lb. rhamnosus GG. These strains are good candidates for further investigation both with in vivo studies to elucidate their potential health benefits and in olive fermentation processes

  4. When familiar social partners are selected in open-ended situations: further tests of the socioemotional selectivity theory.

    Dudley, Nikki M; Multhaup, Kristi S

    2005-01-01

    Socioemotional selectivity theory (SST; Carstensen, 1995, Current Directions in Psychological Science, 4, 151-156) predicts that novel social partners are preferred in open-ended situations, whereas familiar social partners are preferred in future-limited situations. The authors attempted to generalize past research to new familiar and novel partner options. Studies 1 (N=144; undergraduates, community-dwelling adults ages 65 to 95) and 2 (N=336 community-dwelling participants ages 11 to 89) indicated that young and older participants in a future-limited situation preferred familiar partners. However, with different social partner options than have been used in previous research, young participants in an open-ended situation also preferred a familiar partner, contrary to the predictions of SST.

  5. An Aerial Radiological Survey of Selected Areas of Area 18 - Nevada Test Site

    Lyons, Craig

    2009-01-01

    As part of the proficiency training for the Radiological Mapping mission of the Aerial Measuring System (AMS), a survey team from the Remote Sensing Laboratory-Nellis (RSL-Nellis) conducted an aerial radiological survey of selected areas of Area 18 of the Nevada Test Site (NTS) for the purpose of mapping man-made radiation deposited as a result of the Johnnie Boy and Little Feller I tests. The survey area centered over the Johnnie Boy ground zero but also included the ground zero and deposition area of the Little Feller I test, approximately 7,000 feet (2133 meters) southeast of the Johnnie Boy site. The survey was conducted in one flight. The completed survey covered a total of 4.0 square miles. The flight lines (with the turns) over the surveyed areas are presented in Figure 1. One 2.5-hour-long flight was performed at an altitude of 100 ft above ground level (AGL) with 200 foot flight-line spacing. A test-line flight was conducted near the Desert Rock Airstrip to ensure quality control of the data. The test line is not shown in Figure 1. However, Figure 1 does include the flight lines for a ''perimeter'' flight. The path traced by the helicopter flying over distinct roads within the survey area can be used to overlay the survey data on a base map or image. The flight survey lines were flown in an east-west orientation perpendicular to the deposition patterns for both sites. This technique provides better spatial resolution when contouring the data. The data were collected by the AMS data acquisition system (REDAR V) using an array of twelve 2-inch x 4-inch x 16-inch sodium iodide (NaI) detectors flown on-board a twin-engine Bell 412 helicopter. Data, in the form of gamma energy spectra, were collected every second over the course of the survey and were geo-referenced using a differential Global Positioning System. Spectral data allows the system to distinguish between ordinary fluctuations in natural background radiation levels and the signature produced by man

  6. Research borehole drilling activity for boreholes DH-18, DH-19, DC-12, DC-13, DC-14, DC-15, and deepening of existing borehole DC-7

    1979-09-01

    This report is an environmental evaluation of the impacts of proposed borehole drilling activities at the Hanford Site, northwest of Richland, Washington. The proposed action is to drill six research boreholes ranging in depth from 137 to 1372 meters (m) [250 to 4500 +- feet (ft)]. In addition, an existing borehole (DC-7) will be extended from 1249 to 1524 m (4099 to 5000 +- ft). The purpose of the US Department of Energy's (DOE) borehole drilling activities is to collect data on in situ rock formations that are considered potentialy suitable for nuclear waste repositories. The technical program efforts necessary to identify and qualify specific underground waste facility sites in candidate rock formations include geologic and hydrologic studies (seismicity and tectonics, rock structure and stratigraphy, lithology, etc.). Borehole drilling is an integral part of the geological studies and is essential to a thorough understanding of potentially suitable geologic formations. The purpose of the proposed drilling activities is to obtain data for evaluating Columbia River basalts that are being evaluated by the National Waste Terminal Storage (NWTS) Program to determine their suitability potential for nuclear waste repositories. Unavoidable impact to the environment is limited primarily to the clearing of land needed for access and drilling operations. Considerations exercised during site preparation, drilling, and subsequent site restoration will limit modification of the natural environment to the minimum required for accomplishment of test objectives

  7. Voltage Weak DC Distribution Grids

    Hailu, T.G.; Mackay, L.J.; Ramirez Elizondo, L.M.; Ferreira, J.A.

    2017-01-01

    This paper describes the behavior of voltage weak DC distribution systems. These systems have relatively small system capacitance. The size of system capacitance, which stores energy, has a considerable effect on the value of fault currents, control complexity, and system reliability. A number of

  8. Compact integrated dc SQUID gradiometer

    de Waal, V. J.; Klapwijk, T. M.

    1982-10-01

    An all-niobium integrated system of first-order gradiometer and dc suprconducting quantum interference device (SQUID) has been developed. It is relatively simple to fabricate, has an overall size of 17×12 mm and a sensitivity of 3.5×10-12 T m-1 Hz-1/2.

  9. Compact integrated dc SQUID gradiometer

    de Waal, V.J.; Klapwijk, T.M.

    1982-10-01

    An all-niobium integrated system of first-order gradiometer and dc suprconducting quantum interference device (SQUID) has been developed. It is relatively simple to fabricate, has an overall size of 17 x 12 mm and a sensitivity of 3.5 x 10/sup -12/ T m/sup -1/ Hz/sup -1/2/.

  10. Experiments with a DC Motor

    Kraftmakher, Yaakov

    2010-01-01

    Experiments with an electric motor provide good opportunity to demonstrate some basic laws of electricity and magnetism. The aim of the experiments with a low-power dc motor is to show how the motor approaches its steady rotation and how its torque, mechanical power and efficiency depend on the rotation velocity. The tight relationship between the…

  11. Results of winglet development studies for DC-10 derivatives

    Shollenberger, C. A.; Humphreys, J. W.; Heiberger, F. S.; Pearson, R. M.

    1983-01-01

    The results of investigations into the application of winglets to the DC-10 aircraft are presented. The DC-10 winglet configuration was developed and its cruise performance determined in a previous investigation. This study included high speed and low speed wind tunnel tests to evaluate aerodynamic characteristics, and a subsonic flutter wind tunnel test with accompanying analysis and evaluation of results. Additionally, a configuration integration study employed the results of the wind tunnel studies to determine the overall impact of the installation of winglets on the DC-10 aircraft. Conclusions derived from the high speed and low speed tests indicate that the winglets had no significant effects on the DC-10 stability characteristics or high speed buffet. It was determined that winglets had a minimal effect on aircraft lift characteristics and improved the low speed aircraft drag under high lift conditions. The winglets affected the DC-10 flutter characteristics by reducing the flutter speed of the basic critical mode and introducing a new critical mode involving outer wing torsion and longitudinal bending. The overall impact of winglets was determined to be of sufficient benefit to merit flight evaluation.

  12. Diagnostic tests for Helicobacter pylori : A prospective evaluation of their accuracy, without selecting a single test as the gold standard

    Thijs, J C; van Zwet, A A; Thijs, W J; Oey, H B; Karrenbeld, A; Stellaard, F; Luijt, D S; Meyer, B C; Kleibeuker, J H

    1996-01-01

    OBJECTIVE: To assess the accuracy of six commonly used diagnostic tests for Helicobacter pylori in a prospective study without using any specific test as the gold standard (the patient was regarded as H. pylori-infected if two or more tests, whatever their nature, were positive). METHODS: In 105

  13. Development of toroid-type HTS DC reactor series for HVDC system

    Kim, Kwangmin, E-mail: kwangmin81@gmail.com [Changwon National University, 55306 Sarim-dong, Changwon 641-773 (Korea, Republic of); Go, Byeong-Soo; Park, Hea-chul; Kim, Sung-kyu; Kim, Seokho [Changwon National University, 55306 Sarim-dong, Changwon 641-773 (Korea, Republic of); Lee, Sangjin [Uiduk University, Gyeongju 780-713 (Korea, Republic of); Oh, Yunsang [Vector Fields Korea Inc., Pohang 790-834 (Korea, Republic of); Park, Minwon; Yu, In-Keun [Changwon National University, 55306 Sarim-dong, Changwon 641-773 (Korea, Republic of)

    2015-11-15

    Highlights: • The authors developed the 400 mH, 400 A class toroid-type HTS DC reactor system. • The target temperature, inductance and operating current are under 20 K at magnet, 400 mH and 400 A, respectively. All target performances of the HTS DC reactor were achieved. • The HTS DC reactor was conducted through the interconnection operation with a LCC type HVDC system. • Now, the authors are studying the 400 mH, 1500 A class toroid-type HTS DC reactor for the next phase HTS DC reactor. - Abstract: This paper describes design specifications and performance of a toroid-type high-temperature superconducting (HTS) DC reactor. The first phase operation targets of the HTS DC reactor were 400 mH and 400 A. The authors have developed a real HTS DC reactor system during the last three years. The HTS DC reactor was designed using 2G GdBCO HTS wires. The HTS coils of the toroid-type DC reactor magnet were made in the form of a D-shape. The electromagnetic performance of the toroid-type HTS DC reactor magnet was analyzed using the finite element method program. A conduction cooling method was adopted for reactor magnet cooling. The total system has been successfully developed and tested in connection with LCC type HVDC system. Now, the authors are studying a 400 mH, kA class toroid-type HTS DC reactor for the next phase research. The 1500 A class DC reactor system was designed using layered 13 mm GdBCO 2G HTS wire. The expected operating temperature is under 30 K. These fundamental data obtained through both works will usefully be applied to design a real toroid-type HTS DC reactor for grid application.

  14. Development of toroid-type HTS DC reactor series for HVDC system

    Kim, Kwangmin; Go, Byeong-Soo; Park, Hea-chul; Kim, Sung-kyu; Kim, Seokho; Lee, Sangjin; Oh, Yunsang; Park, Minwon; Yu, In-Keun

    2015-01-01

    Highlights: • The authors developed the 400 mH, 400 A class toroid-type HTS DC reactor system. • The target temperature, inductance and operating current are under 20 K at magnet, 400 mH and 400 A, respectively. All target performances of the HTS DC reactor were achieved. • The HTS DC reactor was conducted through the interconnection operation with a LCC type HVDC system. • Now, the authors are studying the 400 mH, 1500 A class toroid-type HTS DC reactor for the next phase HTS DC reactor. - Abstract: This paper describes design specifications and performance of a toroid-type high-temperature superconducting (HTS) DC reactor. The first phase operation targets of the HTS DC reactor were 400 mH and 400 A. The authors have developed a real HTS DC reactor system during the last three years. The HTS DC reactor was designed using 2G GdBCO HTS wires. The HTS coils of the toroid-type DC reactor magnet were made in the form of a D-shape. The electromagnetic performance of the toroid-type HTS DC reactor magnet was analyzed using the finite element method program. A conduction cooling method was adopted for reactor magnet cooling. The total system has been successfully developed and tested in connection with LCC type HVDC system. Now, the authors are studying a 400 mH, kA class toroid-type HTS DC reactor for the next phase research. The 1500 A class DC reactor system was designed using layered 13 mm GdBCO 2G HTS wire. The expected operating temperature is under 30 K. These fundamental data obtained through both works will usefully be applied to design a real toroid-type HTS DC reactor for grid application.

  15. International comparison of AC-DC current transfer standards

    Heine, G.; Garcocz, M.; Waldmann, W.

    2017-01-01

    The measurements of the international comparison of ac-dc current transfer standards identified as EURAMET.EM-K12 started in June 2012 and were completed in December 2014. Twenty NMIs in the EURAMET region and one NMI in the AFRIMET region took part: BEV (Austria), CMI (Czech Republic), PTB (Germany), METAS (Switzerland), JV (Norway), UME (Turkey), GUM (Poland), IPQ (Portugal), CEM (Spain), INRIM (Italy), SP (Sweden), DANIAmet-MI-Trescal (Denmark), BIM (Bulgaria), MKEH (Hungary), SIQ (Slovenia), LNE (France), NSAI NML (Ireland), VSL (The Netherlands), NPL (United Kingdom), Metrosert (Estonia), NIS (Egypt). The comparison was proposed to link the National Metrology Institutes organised in EURAMET to the key comparison CCEM-K12. The ac-dc current transfer difference of each travelling standard had been measured at its nominal current 10 mA and 5 A at the following frequencies: 10 Hz, 55 Hz, 1 kHz, 10 kHz, 20 kHz, 50 kHz, 100 kHz. The test points were selected to link the results with the equivalent CCEM Key Comparison (CCEM-K12), through five NMIs participating in both EURAMET and CCEM key comparisons (PTB, JV, NPL, SP and BEV). The report shows the degree of equivalence in the EURAMET region and also the degree of equivalence with the corresponding CCEM reference value. Main text To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCEM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  16. DC motor operation controlled from a DC/DC power converter in pulse mode with low duty cycle

    Stefanov, Goce; Kukuseva, Maja; Citkuseva Dimitrovska, Biljana

    2016-01-01

    In this paper pulse mode of operation of DC motor controlled by DC/DC power converter is analyzed. DC motor operation with time intervals in which the motor operates without output load is of interest. In this mode it is possible the motor to restore energy. Also, in the paper are represented calculations for the amount of the restored energy in the pulse mode operation of the motor for different duty cycles.

  17. Preoperative testing and risk assessment: perspectives on patient selection in ambulatory anesthetic procedures

    Stierer TL

    2015-08-01

    Full Text Available Tracey L Stierer,1,2 Nancy A Collop3,41Department of Anesthesiology, 2Department of Critical Care Medicine, Otolaryngology Head and Neck Surgery, Johns Hopkins Medicine, Baltimore, MD, USA; 3Department of Medicine, 4Department of Neurology, Emory University, Emory Sleep Center, Wesley Woods Center, Atlanta, GA, USAAbstract: With recent advances in surgical and anesthetic technique, there has been a growing emphasis on the delivery of care to patients undergoing ambulatory procedures of increasing complexity. Appropriate patient selection and meticulous preparation are vital to the provision of a safe, quality perioperative experience. It is not unusual for patients with complex medical histories and substantial systemic disease to be scheduled for discharge on the same day as their surgical procedure. The trend to “push the envelope” by triaging progressively sicker patients to ambulatory surgical facilities has resulted in a number of challenges for the anesthesia provider who will assume their care. It is well known that certain patient diseases are associated with increased perioperative risk. It is therefore important to define clinical factors that warrant more extensive testing of the patient and medical conditions that present a prohibitive risk for an adverse outcome. The preoperative assessment is an opportunity for the anesthesia provider to determine the status and stability of the patient’s health, provide preoperative education and instructions, and offer support and reassurance to the patient and the patient’s family members. Communication between the surgeon/proceduralist and the anesthesia provider is critical in achieving optimal outcome. A multifaceted approach is required when considering whether a specific patient will be best served having their procedure on an outpatient basis. Not only should the patient's comorbidities be stable and optimized, but details regarding the planned procedure and the resources available

  18. Aptitude Tests Versus School Exams as Selection Tools for Higher Education and the Case for Assessing Educational Achievement in Context

    Stringer, Neil

    2008-01-01

    Advocates of using a US-style SAT for university selection claim that it is fairer to applicants from disadvantaged backgrounds than achievement tests because it assesses potential, not achievement, and that it allows finer discrimination between top applicants than GCEs. The pros and cons of aptitude tests in principle are discussed, focusing on…

  19. 40 CFR 1048.410 - How must I select, prepare, and test my in-use engines?

    2010-07-01

    ... my in-use engines? 1048.410 Section 1048.410 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR POLLUTION CONTROLS CONTROL OF EMISSIONS FROM NEW, LARGE NONROAD SPARK-IGNITION ENGINES Testing In-use Engines § 1048.410 How must I select, prepare, and test my in-use engines? (a) You...

  20. Using response-time constraints in item selection to control for differential speededness in computerized adaptive testing

    van der Linden, Willem J.; Scrams, David J.; Schnipke, Deborah L.

    2003-01-01

    This paper proposes an item selection algorithm that can be used to neutralize the effect of time limits in computer adaptive testing. The method is based on a statistical model for the response-time distributions of the test takers on the items in the pool that is updated each time a new item has

  1. Application of digital control techniques for satellite medium power DC-DC converters

    Skup, Konrad R.; Grudzinski, Pawel; Nowosielski, Witold; Orleanski, Piotr; Wawrzaszek, Roman

    2010-09-01

    The objective of this paper is to present a work concerning a digital control loop system for satellite medium power DC-DC converters that is done in Space Research Centre. The whole control process of a described power converter bases on a high speed digital signal processing. The paper presents a development of a FPGA digital controller for voltage mode stabilization that was implemented using VHDL. The described controllers are a classical digital PID controller and a bang-bang controller. The used converter for testing is a simple model of 5-20 W, 200 kHz buck power converter. A high resolution digital PWM approach is presented. Additionally a simple and effective solution of filtering of an analog-to-digital converter output is presented.

  2. DC to DC power converters and methods of controlling the same

    Steigerwald, Robert Louis; Elasser, Ahmed; Sabate, Juan Antonio; Todorovic, Maja Harfman; Agamy, Mohammed

    2012-12-11

    A power generation system configured to provide direct current (DC) power to a DC link is described. The system includes a first power generation unit configured to output DC power. The system also includes a first DC to DC converter comprising an input section and an output section. The output section of the first DC to DC converter is coupled in series with the first power generation unit. The first DC to DC converter is configured to process a first portion of the DC power output by the first power generation unit and to provide an unprocessed second portion of the DC power output of the first power generation unit to the output section.

  3. Analysis of a high power, resonant DC-DC converter for DC wind turbines

    Dincan, Catalin Gabriel; Kjær, Philip Carne; Chen, Yu-Hsing

    2018-01-01

    This paper is introducing a new method of operation for a series resonant converter, with intended application in megawatt high-voltage DC wind turbines. Compared to a frequency controlled series resonant converter operated in sub resonant mode, the method (entitled pulse removal technique) allows...

  4. Dilation and Curettage (D&C)

    ... For Patients About ACOG Dilation and Curettage (D&C) Home For Patients Search FAQs Dilation and Curettage ( ... February 2016 PDF Format Dilation and Curettage (D&C) Special Procedures What is dilation and curettage (D& ...

  5. DESIGN OF A DC/RF PHOTOELECTRON GUN

    YU, D.; NEWSHAM, Y.; SMIRONOV, A.; YU, J.; SMEDLEY, J.; SRINIVASAN RAU, T.; LEWELLEN, J.; ZHOLENTS, A.

    2003-01-01

    An integrated dc/rf photoelectron gun produces a low-emittance beam by first rapidly accelerating electrons at a high gradient during a short (∼1 ns), high-voltage pulse, and then injecting the electrons into an rf cavity for subsequent acceleration. Simulations show that significant improvement of the emittance appears when a high field (∼ 0.5-1 GV/m) is applied to the cathode surface. An adjustable dc gap ((le) 1 mm) which can be integrated with an rf cavity is designed for initial testing at the Injector Test Stand at Argonne National Laboratory using an existing 70-kV pulse generator. Plans for additional experiments of an integrated dc/rf gun with a 250-kV pulse generator are being made

  6. High-temperature steam oxidation testing of select advanced replacement alloys for potential core internals

    Tan, Lizhen [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Pint, Bruce A. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States)

    2017-05-19

    Coupons from a total of fourteen commercial and custom fabricated alloys were exposed to 1 bar full steam with ~10 ppb oxygen content at 600 and 650°C. The coupons were weighed at 500-h intervals with a total exposure time of 5,000 h. The fourteen alloys are candidate alloys selected under the ARRM program, which include three ferritic steels (Grade 92, 439, and 14YWT), three austenitic stainless steels (316L, 310, and 800), seven Ni-base superalloys (X750, 725, C22, 690, 625, 625 direct-aging, and 625- plus), and one Zr-alloy (Zr–2.5Nb). Among the alloys, 316L and X750 are served as reference alloys for low- and high-strength alloys, respectively. The candidate Ni-base superalloy 718 was procured too late to be included in the tests. The corrosion rates of the candidate alloys can be approximately interpreted by their Cr, Ni and Fe content. The corrosion rate was significantly reduced with increasing Cr content and when Ni content is above ~15 wt%, but not much further reduced when Fe content is less than ~55 wt%. Simplified thermodynamics analyses of the alloy oxidation provided reasonable indications for the constituents of oxide scales formed on the alloys and explanations for the porosity and exfoliation phenomena because of the nature of specific types of oxides.

  7. Testing taxon tenacity of tortoises: evidence for a geographical selection gradient at a secondary contact zone

    Edwards, Taylor; Berry, Kristin H.; Inman, Richard D.; Esque, Todd C.; Nussear, Kenneth E.; Jones, Cristina A.; Culver, Melanie

    2015-01-01

    We examined a secondary contact zone between two species of desert tortoise, Gopherus agassizii and G. morafkai. The taxa were isolated from a common ancestor during the formation of the Colorado River (4-8 mya) and are a classic example of allopatric speciation. However, an anomalous population of G. agassizii comes into secondary contact with G. morafkai east of the Colorado River in the Black Mountains of Arizona and provides an opportunity to examine reinforcement of species' boundaries under natural conditions. We sampled 234 tortoises representing G. agassizii in California (n = 103), G. morafkai in Arizona (n = 78), and 53 individuals of undetermined assignment in the contact zone including and surrounding the Black Mountains. We genotyped individuals for 25 STR loci and determined maternal lineage using mtDNA sequence data. We performed multilocus genetic clustering analyses and used multiple statistical methods to detect levels of hybridization. We tested hypotheses about habitat use between G. agassizii and G. morafkai in the region where they co-occur using habitat suitability models. Gopherus agassizii and G. morafkai maintain independent taxonomic identities likely due to ecological niche partitioning, and the maintenance of the hybrid zone is best described by a geographical selection gradient model.

  8. Predicting runoff of suspended solids and particulate phosphorus for selected Louisiana soils using simple soil tests.

    Udeigwe, Theophilus K; Wang, Jim J; Zhang, Hailin

    2007-01-01

    This study was conducted to evaluate the relationships among total suspended solids (TSS) and particulate phosphorus (PP) in runoff and selected soil properties. Nine Louisiana soils were subjected to simulated rainfall events, and runoff collected and analyzed for various parameters. A highly significant relationship existed between runoff TSS and runoff turbidity. Both runoff TSS and turbidity were also significantly related to runoff PP, which on average accounted for more than 98% of total P (TP) in the runoff. Runoff TSS was closely and positively related to soil clay content in an exponential fashion (y=0.10e0.01x, R2=0.91, Psoil electrical conductivity (EC) (y=0.02 x(-3.95), R2=0.70, Psoil suspension turbidity" (SST) which measures turbidity in a 1:200 soil/water suspension, exhibited highly significant linear relationships with runoff TSS (y=0.06x-4.38, R2=0.82, Psoil clay content and EC in a multiple regression, suggesting that SST was able to account for the integrated effect of clay content and electrolytic background on runoff TSS. The SST test could be used for assessment and management of sediment and particulate nutrient losses in surface runoff.

  9. Radiation impact on the characteristics of optical glasses test results on a selected set of materials

    Fruit, Michel; Gussarov, Andrei; Berghmans, Francis; Doyle, Dominic; Ulbrich, Gerd

    2017-11-01

    It is well known within the Space optics community that radiation may significantly affect transmittance of glasses. To overcome this drawback, glass manufacturers have developed Cerium doped counterparts of classical glasses. This doped glasses display much less transmittance sensitivity to radiation. Still, the impact of radiation on refractive index is less known and may affect indifferently classical or Cerium doped glasses. ESTEC has initialised an R&D program with the aim of establishing a comprehensive data base gathering radiation sensitivity data, called Dose coefficients, for all the glass optical parameters (transmittance / refractive index / compaction……). The first part of this study, to define the methodology for such a data base, is run by ASTRIUM SAS in co-operation with SCK CEN. This covers theoretical studies associated to testing of a selected set of classical and "radiation hardened" glasses. It is proposed here to present first the theoretical backgrounds of this study and then to give results which have been obtained so far.

  10. Selection Criteria and Methods for Testing Different Surface Materials for Contact Frying Processes

    Ashokkumar, Saranya

    Inner surfaces of industrial process equipment for food are often coated to give the surfaces particular properties with respect to adhesion and cleanability. Existing coating materials (PTFE (Teflon®) or silicone based polymers) suffer from drawbacks when used in contact frying, because these co...... surface materials for contact frying processes. The surfaces selected for this purpose cover a wide spectrum of materials that range from hydrophobic to hydrophilic materials. The different surface materials investigated include stainless steel (reference), aluminium (Al Mg 5754), PTFE......, an experimental rig has been constructed which enabled a controlled fouling of different coatings on steel and aluminium substrates under realistic frying conditions. A subjective rating procedure was employed for screening different surfaces according to their non-stick properties when used for frying of a model...... defects and surface roughness play a significant role. The wear resistance of the coatings was tested by performing abrasive wear experiments. The ceramic coatings: TiAlN and ZrN were found to show the best wear resistance properties. The experiments also revealed the poor wear resistance of stainless...

  11. Selection of performance-tested young bulls and indirect responses in commercial beef cattle herds on pasture and in feedlots

    Raidan , Fernanda S. S.; Santos , Dalinne C. C.; Moraes , Mariana M.; Araújo , Andresa E. M.; Ventura , Henrique T.; Bergmann , José A. G.; Turra , Eduardo M.; Toral , Fabio L. B.

    2016-01-01

    International audience; AbstractBackgroundCentral testing is used to select young bulls which are likely to contribute to increased net income of the commercial beef cattle herd. We present genetic parameters for growth and reproductive traits on performance-tested young bulls and commercial animals that are raised on pasture and in feedlots.MethodsRecords on young bulls and heifers in performance tests or commercial herds were used. Genetic parameters for growth and reproductive traits were ...

  12. Strategies for implementing genomic selection in family-based aquaculture breeding schemes: double haploid sib test populations

    Nirea Kahsay G

    2012-10-01

    Full Text Available Abstract Background Simulation studies have shown that accuracy and genetic gain are increased in genomic selection schemes compared to traditional aquaculture sib-based schemes. In genomic selection, accuracy of selection can be maximized by increasing the precision of the estimation of SNP effects and by maximizing the relationships between test sibs and candidate sibs. Another means of increasing the accuracy of the estimation of SNP effects is to create individuals in the test population with extreme genotypes. The latter approach was studied here with creation of double haploids and use of non-random mating designs. Methods Six alternative breeding schemes were simulated in which the design of the test population was varied: test sibs inherited maternal (Mat, paternal (Pat or a mixture of maternal and paternal (MatPat double haploid genomes or test sibs were obtained by maximum coancestry mating (MaxC, minimum coancestry mating (MinC, or random (RAND mating. Three thousand test sibs and 3000 candidate sibs were genotyped. The test sibs were recorded for a trait that could not be measured on the candidates and were used to estimate SNP effects. Selection was done by truncation on genome-wide estimated breeding values and 100 individuals were selected as parents each generation, equally divided between both sexes. Results Results showed a 7 to 19% increase in selection accuracy and a 6 to 22% increase in genetic gain in the MatPat scheme compared to the RAND scheme. These increases were greater with lower heritabilities. Among all other scenarios, i.e. Mat, Pat, MaxC, and MinC, no substantial differences in selection accuracy and genetic gain were observed. Conclusions In conclusion, a test population designed with a mixture of paternal and maternal double haploids, i.e. the MatPat scheme, increases substantially the accuracy of selection and genetic gain. This will be particularly interesting for traits that cannot be recorded on the

  13. Hierarchical Power Sharing Control in DC Microgrids

    Peyghami, Saeed; Mokhtari, Hossein; Blaabjerg, Frede

    2016-01-01

    Because of the advances in power electronics, DC-based power systems, have been used in industrial applications such as data centers [18], space applications [10], aircraft [12], offshore wind farms, electric vehicles [56], DC home systems [5, 20], and high-voltage DC transmission systems...

  14. Avaliação da atividade mutagênica da infusão de Baccharis trimera (Less. DC. em teste de Allium cepa e teste de aberrações cromossômicas em linfócitos humanos

    Daiane S. de Pinho

    Full Text Available A carqueja (Baccharis trimera(Less. DC. é uma planta medicinal da família Asteraceae muito utilizada como chá no sul do Brasil no tratamento de doenças renais, intestinas, estomacais e principalmente como emagrecedora. O objetivo desde trabalho foi de avaliar a mutagenicidade in vivoe in vitrodo chá e para isso foi realizado o teste de Allium cepaL. e o de aberrações cromossômicas em linfócitos humanos utilizando quatro tratamentos: T1 (água; T2 (20 g/L de carqueja; T3 (200 g/L de carqueja, e T4 (paracetamol, a 400 mg/L. Ambos os procedimentos foram analisados pelo teste Mann-Whitney U. Este estudo evidencia um efeito mutagênico do chá em células vegetais (Allium cepa e em células humanas (aberrações cromossômicas cultivadas, pois em ambos os testes, T2 e T3 obteve-se uma média mais elevada que nos outros tratamentos. Este estudo demonstra que o efeito é dependente da dose, portanto recomenda-se que o chá de carqueja seja consumido com moderação.

  15. Fatigue and fail-safe design features of the DC-10 airplane

    Stone, M. E.

    1972-01-01

    The philosophy and methods used in the design of the DC-10 aircraft to assure structural reliability against cracks under repeated service loads are described in detail. The approach consists of three complementary parts: (1) the structure is designed to be fatigue resistant for a crack-free life of 60,000 flight hours; (2) inasmuch as small undetected cracks could develop from other sources, such as material flaws and manufacturing preloads, the structure also is designed to arrest and control cracks within a reasonable service-inspection interval; and (3) a meaningful service-inspection program has been defined on the basis of analysis and test experience from the design development program. This service-inspection program closes the loop to assure the structural integrity of the DC-10 airframe. Selected materials, fasteners, and structural arrangements are used to achieve these design features with minimum structural weight and with economy in manufacturing and maintenance. Extensive analyses and testing were performed to develop and verify the design. The basic design considerations for fatigue-resistant structure are illustrated in terms of material selection, design loads spectra, methods for accurate stress and fatigue damage analysis, and proven concepts for efficient detail design.

  16. Characterising and modelling extended conducted electromagnetic interference in densely packed DC-DC converter

    Grobler, Inus

    2013-09-01

    Full Text Available . The military specified DC-DC converters are applicable, spanning from 100 W handheld power managers up to 2 kW DC-DC battery chargers. Circuit layout high frequency effects as well as high frequency impedances of the power components were characterised...

  17. Full wave dc-to-dc converter using energy storage transformers

    Moore, E. T.; Wilson, T. G.

    1969-01-01

    Full wave dc-to-dc converter, for an ion thrustor, uses energy storage transformers to provide a method of dc-to-dc conversion and regulation. The converter has a high degree of physical simplicity, is lightweight and has high efficiency.

  18. Vacuum interrupters used for the interruption of high dc currents

    Warren, R.W.

    1977-01-01

    Conventional ac vacuum interrupters are being used to interrupt currents in pulsed energy storage systems. They have been tested with dc currents of up to 37 kA. The limit to the current which can be successfully interrupted has been measured as a function of various parameters. Among these are (1) the size of the interrupter, (2) the magnitude of the counterpulse current, (3) the nature and flux rating of the saturable reactor used, and (4) the kind of ''snubber'' circuit used. Fragmentary data have also been collected on electrode erosion rates and on mechanical failure of the bellows. A description is given of the circuits used in these tests and of the results found for a representative selection of the commercially available domestic interrupters. More recently efforts have been made to increase the values found for the maximum interruptible current. The techniques used have included connecting interrupters in parallel and operating them in an impressed axial magnetic field. The results of this work are discussed

  19. Transformerless dc-Isolated Converter

    Rippel, Wally E.

    1987-01-01

    Efficient voltage converter employs capacitive instead of transformer coupling to provide dc isolation. Offers buck/boost operation, minimal filtering, and low parts count, with possible application in photovoltaic power inverters, power supplies and battery charges. In photovoltaic inverter circuit with transformerless converter, Q2, Q3, Q4, and Q5 form line-commutated inverter. Switching losses and stresses nil because switching performed when current is zero.

  20. AC-DC PFC Converter Using Combination of Flyback Converter and Full-bridge DC-DC Converter

    Moh. Zaenal Efendi

    2014-06-01

    Full Text Available This paper presents a combination of power factor correction converter using Flyback converter and Full-bridge dc-dc converter in series connection. Flyback converter is operated in discontinuous conduction mode so that it can serve as a power factor correction converter and meanwhile Full-bridge dc-dc converter is used for dc regulator. This converter system is designed to produce a 86 Volt of output voltage and 2 A of output current. Both simulation and experiment results show that the power factor of this converter achieves up to 0.99 and meets harmonic standard of IEC61000-3-2. Keywords: Flyback Converter, Full-bridge DC-DC Converter, Power Factor Correction.

  1. A Feed-Forward Control Realizing Fast Response for Three-Branch Interleaved DC-DC Converter in DC Microgrid

    Haojie Wang

    2016-07-01

    Full Text Available It is a common practice for storage batteries to be connected to DC microgrid buses through DC-DC converters for voltage support on islanded operation mode. A feed-forward control based dual-loop constant voltage PI control for three-branch interleaved DC-DC converters (TIDC is proposed for storage batteries in DC microgrids. The working principle of TIDC is analyzed, and the factors influencing the response rate based on the dual-loop constant voltage control for TIDC are discussed, and then the method of feed-forward control for TIDC is studied to improve the response rate for load changing. A prototype of the TIDC is developed and an experimental platform is built. The experiment results show that DC bus voltage sags or swells caused by load changing can be reduced and the time for voltage recovery can be decreased significantly with the proposed feed-forward control.

  2. A Feed-Forward Control Realizing Fast Response for Three-Branch Interleaved DC-DC Converter in DC Microgrid

    Wang, Haojie; Han, Minxiao; Yan, Wenli

    2016-01-01

    It is a common practice for storage batteries to be connected to DC microgrid buses through DC-DC converters for voltage support on islanded operation mode. A feed-forward control based dual-loop constant voltage PI control for three-branch interleaved DC-DC converters (TIDC) is proposed...... for storage batteries in DC microgrids. The working principle of TIDC is analyzed, and the factors influencing the response rate based on the dual-loop constant voltage control for TIDC are discussed, and then the method of feed-forward control for TIDC is studied to improve the response rate for load...... changing. A prototype of the TIDC is developed and an experimental platform is built. The experiment results show that DC bus voltage sags or swells caused by load changing can be reduced and the time for voltage recovery can be decreased significantly with the proposed feed-forward control....

  3. Safety properties test data selection from an algebraic model of Lustre programs; Selection de tests de proprietes de surete a partir d'une modelisation algebrique de programmes lustre

    Hsiao, N.Ch

    1995-07-01

    In the context to validate an industrial software, which is a set of reactive programs, we are confronted with the safety properties verification problem. This thesis reports an experience in which our goal is to generate the test data satisfying a safety property. The software to be validated is designed with the SAGA tool, in which a view can be regarded as a program of a programming language called LUSTRE. We adapt a test data generation tool called LOFT to this kind of programs. In this way, we consider the functional testing method on which the LOFT tool is based. Given any LUSTRE program, we try to give it an algebraic model because LOFT treats algebraic specifications. So, our task consists In defining a formal framework in which any LUSTRE program can be translated into a LOFT module: based on an operational semantics of the LUSTRE language, the flow types 'T-flow' are specified with the constructive algebraic formalism, then implemented in a LOFT modules base. Next, in a test selection process assisted by LOFT, a safety property Is expressed by an equation to join other control hypotheses, and to guide the test data selection. Some concrete test data set are generated in this way on some significant examples. This experience confirm the feasibility of formal method on test data selection for the reactive programs. (author)

  4. Functional evaluation of bone marrow derived DC of tumor bearing mice after immunotherapy

    Li Min; Chen Cheng; Gu Tao; Zhou Huan; Zhang Feng; Zhu Yibei; Yu Gehua; Zhang Xueguang; Gu Zongjiang

    2006-01-01

    Objective: To evaluate the function of bone marrow derived DC of tumor bearing mice after immunotherapy. Methods: Tumor bearing mice were immunized with DC vaccine plus injection of agonistic anti-4-1BB monoclonal antibody. The proliferation of T cells primed with bone marrow derived DC of tumor bearing mice after immunotherapy was tested by 3 H-TdR incorporation. ELISA was employed to determine the levels of IL-2, IFN-γ and IL-10 secreted by DC primed T cells. Results: Bone marrow derived DC of tumor bearing mice was less efficient in stimulating the proliferation of T cells and IL-2 and IFN-γ secretion made by T cells. After immunotherapy, the proliferation of cells and IL-2 and IFN-γ secretionmade by T cells were enhanced. Conclusion: The function of bone marrow derived DC of tumor bearing mice after immunotherapy was ameliorated. (authors)

  5. FLYWHEEL AND A DC MACHINE

    IVAN ALCALÁ

    2014-01-01

    Full Text Available Este artículo describe el análisis, modelado y simulación de un vehículo eléctrico (EV enfocado al desarrollo de un banco de pruebas para reproducir la dinámica del EV. El banco está formado por un drive de motor de inducción (IM acoplado directamente a una máquina de DC y a un volante de inercia a través de una transmisión. El volante de inercia y la máquina de DC reproducen la dinámica y las fuerzas que actúan en el vehículo. Se propone una metodología para diseñar un banco de pruebas de EV para estudiar el comportamiento de vehículos eléctricos cercano a las condiciones de operación reales. El análisis de las fuerzas en el EV en conjunto con la máquina DC define las condiciones de operación del EV. El modelado y la simulación son desarrollados en MATLAB/Simulink, el banco de pruebas implementado es controlado por un DSP. Finalmente, los resultados de simulación y experimentales obtenidos validan el funcionamiento del banco de prueba.

  6. A soft-switching coupled inductor bidirectional DC-DC converter with high-conversion ratio

    Chao, Kuei-Hsiang; Jheng, Yi-Cing

    2018-01-01

    A soft-switching bidirectional DC-DC converter is presented herein as a way to improve the conversion efficiency of a photovoltaic (PV) system. Adoption of coupled inductors enables the presented converter not only to provide a high-conversion ratio but also to suppress the transient surge voltage via the release of the energy stored in leakage flux of the coupled inductors, and the cost can kept down consequently. A combined use of a switching mechanism and an auxiliary resonant branch enables the converter to successfully perform zero-voltage switching operations on the main switches and improves the efficiency accordingly. It was testified by experiments that our proposed converter works relatively efficiently in full-load working range. Additionally, the framework of the converter intended for testifying has high-conversion ratio. The results of a test, where a generating system using PV module array coupled with batteries as energy storage device was used as the low-voltage input side, and DC link was used as high-voltage side, demonstrated our proposed converter framework with high-conversion ratio on both high-voltage and low-voltage sides.

  7. Analysis and Controller Design of a Universal Bidirectional DC-DC Converter

    Kou-Bin Liu

    2016-06-01

    Full Text Available In this paper, first the operating principles of a non-isolated universal bidirectional DC-DC converter are studied and analyzed. The presented power converter is capable of operating in all power transferring directions in buck/boost modes. Zero voltage switching can be achieved for all the power switches through proper modulation strategy design, therefore, the presented converter can achieve high efficiency. To further improve the efficiency, the relationship between the phase-shift angle and the overall system efficiency is analyzed in detail, an adaptive phase-shift (APS control method which determines the phase-shift value between gating signals according to the load level is then proposed. As the modulation strategy is a software-based solution, there is no requirement for additional circuits, therefore, it can be implemented easily and instability and noise susceptibility problems can be reduced. To validate the correctness and the effectiveness of the proposed method, a 300 W prototyping circuit is implemented and tested. A low cost dsPIC33FJ16GS502 digital signal controller is adopted in this paper to realize the power flow control, DC-bus voltage regulation and APS control. According to the experimental results, a 12.2% efficiency improvement at light load and 4.0% efficiency improvement at half load can be achieved.

  8. Severe selective magnesium malabsorption: tests of tolerance of oral magnesium supplements.

    Mettey, R; Guillard, O; Merle, P; Maillet-Picker, F

    1990-12-01

    Since his birth, we have been monitoring a 12-year-old boy suffering from selective severe magnesium malabsorption. Our essential problem is to prepare a form of galena with acceptable taste, tolerated by the digestive tract and well absorbed; also, the carrier compound must not cause short- or long-term side effects. An additional factor is the steadily increasing need for magnesium from 1 mmol/kg.d at 1 year to 14 mmol/kg.d at present age (345 mg/kg.d). The galena forms currently on sale were, with the exception of lactate and pyrollidone carboxylate, immediately rejected since they contain insufficient Mg2+. Following short trials resulting in diarrhoea, the other two preparations were also rejected. We then constituted - and also abandoned - our own galena compounds: aspartate (bitterness), aspartate + glycerophosphate (GLP) (bitterness), glutamate + GLP ('Chinese restaurant syndrome' and fear of the long term toxic effect of the glutamate), gluconate (excessive volume: 11/1 proportion with Mg2+). A recent test featuring GLP of Mg 40 g + cocoa butter 40 g + cocoa 10 g, brought about vomiting and diarrhoea, and was not adequately absorbed. The best tolerated formula is: Mg GLP 21.33 g; saccharose 6 g; aspartam 1 g; gelatin 0.5 g; citric acid, conserving agent, fruity aroma; water: qs 100 g. Such composition yields a caramel cream absorbed in five small portions, at a daily quantity of 375 g (80 g GLP Mg, 10 g Mg2+). Vitamin B6, which promotes intestinal absorption of magnesium, must be given separately in tablet form at a dose of 1 g/d, since it causes nausea if it is included in the Mg preparation.(ABSTRACT TRUNCATED AT 250 WORDS)

  9. Environmental risk assessment of selected organic chemicals based on TOC test and QSAR estimation models.

    Chi, Yulang; Zhang, Huanteng; Huang, Qiansheng; Lin, Yi; Ye, Guozhu; Zhu, Huimin; Dong, Sijun

    2018-02-01

    Environmental risks of organic chemicals have been greatly determined by their persistence, bioaccumulation, and toxicity (PBT) and physicochemical properties. Major regulations in different countries and regions identify chemicals according to their bioconcentration factor (BCF) and octanol-water partition coefficient (Kow), which frequently displays a substantial correlation with the sediment sorption coefficient (Koc). Half-life or degradability is crucial for the persistence evaluation of chemicals. Quantitative structure activity relationship (QSAR) estimation models are indispensable for predicting environmental fate and health effects in the absence of field- or laboratory-based data. In this study, 39 chemicals of high concern were chosen for half-life testing based on total organic carbon (TOC) degradation, and two widely accepted and highly used QSAR estimation models (i.e., EPI Suite and PBT Profiler) were adopted for environmental risk evaluation. The experimental results and estimated data, as well as the two model-based results were compared, based on the water solubility, Kow, Koc, BCF and half-life. Environmental risk assessment of the selected compounds was achieved by combining experimental data and estimation models. It was concluded that both EPI Suite and PBT Profiler were fairly accurate in measuring the physicochemical properties and degradation half-lives for water, soil, and sediment. However, the half-lives between the experimental and the estimated results were still not absolutely consistent. This suggests deficiencies of the prediction models in some ways, and the necessity to combine the experimental data and predicted results for the evaluation of environmental fate and risks of pollutants. Copyright © 2016. Published by Elsevier B.V.

  10. Well coupled, low noise, dc SQUIDS

    Muhlfelder, B.; Beall, J.A.; Cromar, M.W.; Johnson, W.W.; Ono, R.H.

    1985-01-01

    The authors have designed, fabricated, and tested a Double Transformer (DT) coupled dc SQUID (Superconducting Quantum Interference Device) with low noise, an input inductance of 1μH and a smooth input-output characteristic. A transmission line model is presented to explain a resonance in the input-output characteristic of early versions of this device. Guided by the results of numerical simulations a new version of this device has been built and tested. Experimental results are presented that show that the resonance can be moved to a higher voltage by reducing the area of the SQUID loop. The voltage-external flux characteristic of some of these new devices agrees to within 10% with computer simulations. The minimum detectable energy per unit bandwidth (MDE) referred to the SQUID loop, is 10h, where h is Planck's constant. Computer simulations indicate an MDE of 6h

  11. Quasi-Z-Source Half-Bridge DC-DC Converter for Photovoltaic Applications

    Vinnikov, D; Chub, A; Husev, O; Zaķis, J

    2015-01-01

    This paper presents a novel quasi-Z-source halfbridge galvanically isolated DC-DC converter intended for the photovoltaic applications. The topology could be envisioned as an alternative to the boost half-bridge DC-DC converter but the benefit of its symmetric structure reduces the threat of transformer saturation due to the dc flux. The proposed converter features the continuous input current and could be used either with one or two input voltage sources.

  12. Control of the DC-DC Converter used into Energy Generation System

    Bizon, Nicu; Oproescu, Mihai

    2006-01-01

    This paper presents an investigation of the DC-DC Converter controller used into Energy Generation System. The full bridge is used into an Energy Generation System (EGS) as second power interface between the energy source and the high DC bus. The simulation results show that the DC-DC Converter behavior can be improved using a well designed PI control surface. The used Simulink models for the EGS blocks and some design considerations are presented, too. (authors)

  13. Results of the ESA study on psychological selection of astronaut applicants for Columbus missions I: Aptitude testing

    Fassbender, Christoph; Goeters, Klaus-Martin

    European participation in the Space Station Freedom brought about new challenges for the psychological selection of astronaut candidates, particularly in respect to specific demands of long duration space flights. For this reason existing selection criteria and methods were reassessed. On these grounds a study was undertaken applying a unique composition of aptitude tests to a group of 97 ESA scientists and engineers who are highly comparable to the expected astronaut applicants with respect to age and education. The tests assessed operational aptitudes such as logical reasoning, memory function, perception, spatial orientation, attention, psychomotor function, and multiple task capacity. The study goals were: 1) Verification of psychometric qualities and applicability of tests in a normative group; 2) Search for culture-fair tests by which multi-national groups can be examined; 3) Identification of test methods which consider general and special operational demands of long duration space flights. Based on the empirical findings a test battery was arranged for use in the selection of ESA astronaut applicants. Results showed that 16 out of the 18 employed tests have good psychometric qualities and differentiate reliably in the special group of testees. The meta structure of the test battery as described by a factorial analysis is presented. Applicability of tests was generally high. Tests were culture-fair, however, a relation between English language skills and test results was identified. Since most item material was language-free, this was explained with the importance of English language skills for the understanding of test instructions. Solutions to this effect are suggested.

  14. Design of double DC motor control system based on DSP

    Suo WANG

    2017-10-01

    Full Text Available Aiming at the problems of speed control, commutation and so on in the multi-motor synchronous control system, based on automatic control technology, a control system with PC as principal computer and DSP as slave computer is designed, which can change dual DC motor speed and steering, as well as select work drive motors. Related hardware and software design of the control system are given. Through serial communication between DSP and PC using PC serial port software, digital control command is sent to the slave computer for controlling dual DC motor to do a series of preset functions. PWM pulse width modulation is used for motor speed regulation, photoelectric encoder is used to measure motor speed by T method, and the motor speed is displayed by the actual waveform. Experimental results show that the system can not only realize the synchronization of dual DC motor speed and steering adjustment, but also select the motor and achieve the dual DC motors synchronization control effect. The control system has certain reliability and effectiveness.

  15. Assessing Spoken Language Competence in Children with Selective Mutism: Using Parents as Test Presenters

    Klein, Evelyn R.; Armstrong, Sharon Lee; Shipon-Blum, Elisa

    2013-01-01

    Children with selective mutism (SM) display a failure to speak in select situations despite speaking when comfortable. The purpose of this study was to obtain valid assessments of receptive and expressive language in 33 children (ages 5 to 12) with SM. Because some children with SM will speak to parents but not a professional, another purpose was…

  16. Laying hens selected for low mortality: Behaviour in tests of fearfulness, anxiety and cognition

    Nordquist, R.E.; Heerkens, J.L.T.; Rodenburg, T.B.; Boks, S.; Ellen, E.D.; Staaij, van der F.

    2011-01-01

    Feather pecking and cannibalism in chickens can lead to injury or to death of the victims, and is thus a serious welfare and economic issue in modern poultry farming. A sib selection scheme has been initiated to genetically select a low mortality line (LML), which shows decreased mortality due to

  17. Discussion - a high voltage DC generator

    Bhagwat, P.V.; Singh, Jagir; Hattangadi, V.A.

    1993-01-01

    One of the requirements for a high power ion source is a high voltage, high current DC generator. The high voltage, high current generator, DISCATRON, presently under development in our laboratory is a rotating disc type electrostatic generator similar in design to the one reported by A. Isoya et al. (1985). It is compact and rugged electrostatic DC generator based on the principle of induction charging by pellet chains used in the pelletron accelerator. It is, basically, a constant-current device with little stored energy, so that, in case of a breakdown, damage to the equipment connected to the output terminals is minimal. Since the present generator is only a proto-type, meant for a study of the practical difficulties that would be encountered in its manufacture, the output voltage and current specified has been kept quite modest viz., 300 kV at 500 μA, maximum. Some results of the preliminary tests carried out with this generator are described. (author). 4 figs

  18. Monitoring dc stray current corrosion at sheet pile structures

    Peelen, W.H.A.; Neeft, E.A.C.; Leegwater, G.; Kanten-Roos, W. van; Courage, W.M.G.

    2012-01-01

    Steel is discarded by railway owners as a material for underground structures near railway lines, due to uncertainty over increased corrosion by DC stray currents stemming from the traction power system. This paper presents a large scale field test in which stray currents interference of a sheet

  19. Development of DC-TOF control software framework

    Kim, Hong Joo; Kim, Hyun Ok

    2010-06-01

    Disk-Chopper Time-of-Flight spectrometer (DC-TOF) is a new cold neutron instrument under construction at the Korea Atomic Energy Research Institute (KAERI). It will be equipped with a total of 352 2m PSDs(Position Sensitive Detectors), which are grouped into 11 panels. We developed the main DAQ/Control software works well between multi-DSPs of electronics and user. It is convenient to operate DC-TOF system and monitor it's data quality using GUI(Graphical User Interface). Also it satisfies design throughout with test result of 100K events/s

  20. Association between composites of selected motion palpation and pain provocation tests for sacroiliac joint disorders.

    Soleimanifar, Manijeh; Karimi, Noureddin; Arab, Amir Massoud

    2017-04-01

    The sacroiliac joint (SIJ) has been implicated as a potential source of low back and buttock pain. Several types of motion palpation and pain provocation tests are used to evaluate SIJ dysfunction. The purpose of this study was to investigate the relationship between motion palpation and pain provocation tests in assessment of SIJ problems. This study is Descriptive Correlation. 50 patients between the ages of 20 and 65 participated. Four motion palpation tests (Sitting flexion, Standing flexion, Prone knee flexion, Gillet test) and three pain provocation tests (FABER, Posterior shear, Resisted abduction test) were examined. Chi-square analysis was used to assess the relationship between results of the individuals and composites of these two groups of tests. No significant relationship was found between these two groups of tests. It seems that motion palpation tests assess SIJ dysfunction and provocative tests assessed SIJ pain which do not appear to be related. Copyright © 2016 Elsevier Ltd. All rights reserved.

  1. Selection of dissolution process for spent fuels and preparation of corrosion test solution simulated to dissolver (contract research)

    Motooka, Takafumi; Terakado, Shogo; Koya, Toshio; Hamada, Shozo; Kiuchi, Kiyoshi

    2001-03-01

    In order to evaluate the reliability of reprocessing equipment materials used in the Rokkasho Reprocessing Plant, we have proceeded a mock-up test and laboratory tests for getting corrosion parameters. In a dissolver made of zirconium, the simulation of test solutions to the practical solution which includes the high concentration of radioactive elements such as FP and TRU is one of the important issues with respect to the life prediction. On this experiment, the dissolution process of spent fuels and the preparation of test solution for evaluating the corrosion resistance of dissolver materials were selected. These processes were tested in the No.3 cell of WASTEF. The test solution for corrosion tests was prepared by adjusting the uranium and nitric acid concentrations. (author)

  2. A Feedback Passivation Design for DC Microgrid and Its DC/DC Converters

    Feifan Ji

    2016-12-01

    Full Text Available There are difficulties in analyzing the stability of microgrids since they are located on various network structures. However, considering that the network often consists of passive elements, the passivity theory is applied in this paper to solve the above-mentioned problem. It has been formerly shown that when the network is weakly strictly positive real (WSPR, the DC microgrid is stable if all interfaces between the microgrid and converters are made to be passive, which is called interface passivity. Then, the feedback passivation method is proposed for the controller design of various DC–DC converters to achieve the interface passivity. The interface passivity is different from the passivity of closed-loop systems on which the passivity based control (PBC concentrates. The feedback passivation design is detailed for typical buck converters and boost converters in terms of conditions that the controller parameters should satisfy. The theoretical results are verified by a hardware-in-loop real-time labotray (RTLab simulation of a DC microgrid with four generators.

  3. Hearings Before the Select Committee on Nutrition and Human Needs of the United States Senate, Ninety-Third Congress, First Session. Nutrition Education--1973. Part 6--Phosphate Research and Dental Decay. Hearings Held Washington, D.C., April 16, 1973.

    Congress of the U.S., Washington, DC. Senate Select Committee on Nutrition and Human Needs.

    These hearings before the Select Committee on Nutrition and Human Needs of the United States Senate include testimony on the subject of research into the use of phosphates to prevent dental decay. The purpose of the hearing was to explore certain dental health questions raised during the committee's recent hearings on the Television Advertising of…

  4. Testing the Effects of Peer Socialization versus Selection on Alcohol and Marijuana Use among Treated Adolescents

    Becker, Sara J.; Curry, John F.

    2014-01-01

    This study examined the relative influence of peer socialization and selection on alcohol and marijuana use among 106 adolescents who received a brief intervention. Adolescents were recruited between 2003 and 2007 and followed for 12 months as part of a SAMHSA-funded study. Cross-lagged panel models using four assessment points examined the longitudinal relationship between adolescent substance use and peer substance involvement separately for alcohol and marijuana. Consistent with community studies, there was evidence of both peer socialization and peer selection for alcohol use, and only evidence of peer selection for marijuana use. Implications for research and intervention are discussed. PMID:23965039

  5. Development of energy storage system for DC electric rolling stock applying electric double layer capacitor

    Sekijima, Y.; Kudo, Y.; Inui, M. [Central Japan Railway Co., Aichi (Japan); Monden, Y.; Toda, S.; Aoyama, I. [Toshiba Corp., Tokyo (Japan)

    2006-07-01

    This paper provided details of an energy storage system designed for use with DC electric rolling stock through the application of an electric double layer capacitor (EDLC). The EDLC was selected due to its long life-span and its low operational costs. Testing was conducted to assess the system's basic control function, acceleration using stored energy, and behaviour during regenerative brake failure. A control circuit chip was used in the DC electric rolling stock on an inverter of the energy storage system. Tests confirmed that the control method was effective for actual rolling stocks. A full-scale energy storage system for installation on series 313 locomotives was then constructed. Braking energy was generated only from a regenerative brake. In case of brake failure, braking energy was generated from an air brake was well as an electric brake. Data from a field test conducted at the Tokaido and Chuo railway lines showed a capacity of 0.6 kWh. The EDLC was used to reduce peak air brake energy. It was concluded that storing 0.28 kW of brake energy in the EDLC can reduce peaks of air brake energy in high speed ranges. Experimental equipment was used to confirm use of the system with 0.56 kWh of EDLC, the average energy of air brake used in regenerative energy failure. 1 tab., 10 figs.

  6. Tracers and Tracer Testing: Design, Implementation, Tracer Selection, and Interpretation Methods

    G. Michael Shook; Shannon L.; Allan Wylie

    2004-01-01

    Conducting a successful tracer test requires adhering to a set of steps. The steps include identifying appropriate and achievable test goals, identifying tracers with the appropriate properties, and implementing the test as designed. When these steps are taken correctly, a host of tracer test analysis methods are available to the practitioner. This report discusses the individual steps required for a successful tracer test and presents methods for analysis. The report is an overview of tracer technology; the Suggested Reading section offers references to the specifics of test design and interpretation.

  7. Design And Simulation Of A PV System With Battery Storage Using Bidirectional DC-DC Converter Using Matlab Simulink

    Mirza Mursalin Iqbal

    2017-07-01

    Full Text Available PV Photovoltaic systems are one of the most renowned renewable green and clean sources of energy where power is generated from sunlight converting into electricity by the use of PV solar cells. Unlike fossil fuels solar energy has great environmental advantages as they have no harmful emissions during power generation. In this paper a PV system with battery storage using bidirectional DC-DC converter has been designed and simulated on MATLAB Simulink. The simulation outcomes verify the PV systems performance under standard testing conditions.

  8. Evaluation of Adverse Impact for US Air Force Officer and Aircrew Selection Tests

    Carretta, Thomas R

    2006-01-01

    .... Results indicated that strict application of the current minimum qualifying standards, along with top-down selection of qualified applicants, would lead to adverse impact for females and racial...

  9. Effects of bedding systems selected by manual muscle testing on sleep and sleep-related respiratory disturbances.

    Tsai, Ling-Ling; Liu, Hau-Min

    2008-03-01

    In this study, we investigated the feasibility of applying manual muscle testing (MMT) for bedding selection and examined the bedding effect on sleep. Four lay testers with limited training in MMT performed muscle tests for the selection of the bedding systems from five different mattresses and eight different pillows for 14 participants with mild sleep-related respiratory disturbances. For each participant individually, two bedding systems-one inducing stronger muscle forces and the other inducing weaker forces-were selected. The tester-participant pairs showed 85% and 100% agreement, respectively, for the selection of mattresses and pillows that induced the strongest muscle forces. The firmness of the mattress and the height of the pillow were significantly correlated with the body weight and body mass index of the participants for the selected strong bedding system but not for the weak bedding system. Finally, differences were observed between the strong and the weak bedding systems with regard to sleep-related respiratory disturbances and the percentage of slow-wave sleep. It was concluded that MMT can be performed by inexperienced testers for the selection of bedding systems.

  10. Focused evaluation of selected remedial alternatives for the underground test area

    1997-04-01

    The Nevada Test Site (NTS), located in Nye County in southern Nevada, was the location of 928 nuclear tests conducted between 1951 and 1992. Of the total tests, 824 were nuclear tests performed underground. This report describes the approach taken to determine whether any specific, proven, cost-effective technologies currently exist to aid in the removal of the radioactive contaminants from the groundwater, in the stabilization of these contaminants, and in the removal of the source of the contaminants

  11. 40 CFR 1048.310 - How must I select engines for production-line testing?

    2010-07-01

    ... intervals for a one-tail distribution. σ = Test sample standard deviation (see paragraph (c)(2) of this section). x = Mean of emission test results of the sample. STD = Emission standard. (1) Determine the 95...)). (e) After each new test, recalculate the required sample size using the updated mean values, standard...

  12. 40 CFR 1054.310 - How must I select engines for production-line testing?

    2010-07-01

    ...% confidence intervals for a one-tail distribution. σ = Test sample standard deviation (see paragraph (c)(2) of this section). x = Mean of emission test results of the sample. STD = Emission standard (or family...)). (e) After each new test, recalculate the required sample size using the updated mean values, standard...

  13. A Comparison of Procedures for Content-Sensitive Item Selection in Computerized Adaptive Tests.

    Kingsbury, G. Gage; Zara, Anthony R.

    1991-01-01

    This simulation investigated two procedures that reduce differences between paper-and-pencil testing and computerized adaptive testing (CAT) by making CAT content sensitive. Results indicate that the price in terms of additional test items of using constrained CAT for content balancing is much smaller than that of using testlets. (SLD)

  14. On the issue of item selection in computerized adaptive testing with response times

    Veldkamp, Bernard P.

    2016-01-01

    Many standardized tests are now administered via computer rather than paper-and-pencil format. The computer-based delivery mode brings with it certain advantages. One advantage is the ability to adapt the difficulty level of the test to the ability level of the test taker in what has been termed

  15. Testing the prediction from sexual selection of a positive genetic correlation between human mate preferences and corresponding traits

    Verweij, K.J.H.; Burri, A.V.; Zietsch, B.P.

    2014-01-01

    Sexual selection can cause evolution in traits that affect mating success, and it has thus been implicated in the evolution of human physical and behavioural traits that influence attractiveness. We use a large sample of identical and nonidentical female twins to test the prediction from mate choice

  16. Developing and Validating a Rapid Small-Scale Column Test Procedure for GAC Selection using Reconstituted Lyophilized NOM

    Cost effective design and operation of Granular Activated Carbon (GAC) facilities requires the selection of GAC that is optimal for a specific site. Rapid small-scale column tests (RSSCTs) are widely used for GAC assessment due to several advantages, including the ability to simu...

  17. The Relationship Between Selected Subtests of the Detroit Tests of Learning Aptitude and Second Grade Reading Achievement.

    Sherwood, Charles; Chambless, Martha

    Relationships between reading achievement and perceptual skills as measured by selected subtests of the Detroit Tests of Learning Aptitude were investigated in a sample of 73 second graders. Verbal opposites, visual memory for designs, and visual attention span for letters were significantly correlated with both word meaning and vocabulary…

  18. Spinal fusion for chronic low back pain: systematic review on the accuracy of tests for patient selection

    Willems, P.C.P.H.; Staal, J.B.; Walenkamp, G.H.; Bie, R.A. de

    2013-01-01

    BACKGROUND CONTEXT: Spinal fusion is a common but controversial treatment for chronic low back pain (LBP) with outcomes similar to those of programmed conservative care. To improve the results of fusion, tests for patient selection are used in clinical practice. PURPOSE: To determine the prognostic

  19. Optimal selection for BRCA1 and BRCA2 mutation testing using a combination of ' easy to apply ' probability models

    Bodmer, D.; Ligtenberg, M. J. L.; van der Hout, A. H.; Gloudemans, S.; Ansink, K.; Oosterwijk, J. C.; Hoogerbrugge, N.

    2006-01-01

    To establish an efficient, reliable and easy to apply risk assessment tool to select families with breast and/or ovarian cancer patients for BRCA mutation testing, using available probability models. In a retrospective study of 263 families with breast and/or ovarian cancer patients, the utility of

  20. Personnel selection between aptitude tests and character assessment. The changing expertise of military psychologists in Germany, 1914-1942

    Petri, S

    2004-01-01

    This article traces the changing methodological principles in the process of the institutionalization of German military psychology. The paper argues that during the development of selection procedures for officer cadets, military psychologists shaped their tests along the general lines of personnel

  1. Experiments with a dc motor

    Kraftmakher, Yaakov

    2010-01-01

    Experiments with an electric motor provide good opportunity to demonstrate some basic laws of electricity and magnetism. The aim of the experiments with a low-power dc motor is to show how the motor approaches its steady rotation and how its torque, mechanical power and efficiency depend on the rotation velocity. The tight relationship between the mechanical and electrical parameters of the motor is clearly seen. The measurements are carried out with the ScienceWorkshop data-acquisition system and the DataStudio software from PASCO scientific. The experiments are well related to university courses of electricity and magnetism and can be used in undergraduate laboratories or for lecture demonstrations.

  2. ALA-PDT mediated DC vaccine for skin squamous cell carcinoma

    Ji, Jie; Fan, Zhixia; Zhou, Feifan; Wang, Xiaojie; Shi, Lei; Zhang, Haiyan; Wang, Peiru; Yang, Degang; Zhang, Linglin; Wang, Xiuli; Chen, Wei R.

    2015-03-01

    Dendritic cell (DC) based vaccine has emerged as a promising immunotherapy for cancers. However, most DC vaccines so far have only achieved limited success in cancer treatment. Photodynamic therapy (PDT), an established cancer treatment strategy, can cause immunogenic apoptosis to induce an effective antitumor immune response. In this study, we developed a DC-based cancer vaccine using immunogenic apoptotic tumor cells induced by 5-aminolevulinic acid (ALA) mediated PDT. The maturation of DCs induced by PDT-treated apoptotic cells was evaluated. The anti-tumor immunity of ALA-PDT-DC vaccine was tested with mouse model. We observed the maturations of DCs potentiated by ALA-PDT treated tumor cells, including phenotypic maturation (upregulation of surface expression of MHC-II, DC80, and CD86), and functional maturation (enhanced capability to secret INF-Υ and IL-12). ALA-PDT-DC vaccine mediated by apoptotic cells provided protection against tumor in mice, far stronger than that of DC vaccine obtained from freeze/thaw treated tumor cells. Our results indicate that immunogenic apoptotic tumor cells can be more effective in enhancing DC-based cancer vaccine, which could improve the clinical application of PDT- DC vaccines.

  3. Coordination Control Strategy for AC/DC Hybrid Microgrids in Stand-Alone Mode

    Dwi Riana Aryani

    2016-06-01

    Full Text Available Interest in DC microgrids is rapidly increasing along with the improvement of DC power technology because of its advantages. To support the integration process of DC microgrids with the existing AC utility grids, the form of hybrid AC/DC microgrids is considered for higher power conversion efficiency, lower component cost and better power quality. In the system, AC and DC portions are connected through interlink bidirectional AC/DC converters (IC with a proper control system and power management. In the stand-alone operation mode of AC/DC hybrid microgrids, the control of power injection through the IC is crucial in order to maintain the system security. This paper mainly deals with a coordination control strategy of IC and a battery energy storage system (BESS converter under stand-alone operation. A coordinated control strategy for the IC, which considers the state of charge (SOC level of BESS and the load shedding scheme as the last resort, is proposed to obtain better power sharing between AC and DC subgrids. The scheme will be tested with a hybrid AC/DC microgrid, using the tool of the PSCAD/EMTDC software.

  4. Development of toroid-type HTS DC reactor series for HVDC system

    Kim, Kwangmin; Go, Byeong-Soo; Park, Hea-chul; Kim, Sung-kyu; Kim, Seokho; Lee, Sangjin; Oh, Yunsang; Park, Minwon; Yu, In-Keun

    2015-11-01

    This paper describes design specifications and performance of a toroid-type high-temperature superconducting (HTS) DC reactor. The first phase operation targets of the HTS DC reactor were 400 mH and 400 A. The authors have developed a real HTS DC reactor system during the last three years. The HTS DC reactor was designed using 2G GdBCO HTS wires. The HTS coils of the toroid-type DC reactor magnet were made in the form of a D-shape. The electromagnetic performance of the toroid-type HTS DC reactor magnet was analyzed using the finite element method program. A conduction cooling method was adopted for reactor magnet cooling. The total system has been successfully developed and tested in connection with LCC type HVDC system. Now, the authors are studying a 400 mH, kA class toroid-type HTS DC reactor for the next phase research. The 1500 A class DC reactor system was designed using layered 13 mm GdBCO 2G HTS wire. The expected operating temperature is under 30 K. These fundamental data obtained through both works will usefully be applied to design a real toroid-type HTS DC reactor for grid application.

  5. DC Voltage Control and Power-Sharing of Multi-Terminal DC Grids Based on Optimal DC Power Flow and Flexible Voltage Droop Strategy

    F. Azma

    2015-06-01

    Full Text Available This paper develops an effective control framework for DC voltage control and power-sharing of multi-terminal DC (MTDC grids based on an optimal power flow (OPF procedure and the voltage-droop control. In the proposed approach, an OPF algorithm is executed at the secondary level to find optimal reference of DC voltages and active powers of all voltage-regulating converters. Then, the voltage droop characteristics of voltage-regulating converters, at the primary level, are tuned based on the OPF results such that the operating point of the MTDC grid lies on the voltage droop characteristics. Consequently, the optimally-tuned voltage droop controller leads to the optimal operation of the MTDC grid. In case of variation in load or generation of the grid, a new stable operating point is achieved based on the voltage droop characteristics. By execution of a new OPF, the voltage droop characteristics are re-tuned for optimal operation of the MTDC grid after the occurrence of the load or generation variations. The results of simulation on a grid inspired by CIGRE B4 DC grid test system demonstrate efficient grid performance under the proposed control strategy.

  6. Neisseria meningitidis expressing lgtB lipopolysaccharide targets DC-SIGN and modulates dendritic cell function.

    Steeghs, Liana; van Vliet, Sandra J; Uronen-Hansson, Heli; van Mourik, Andries; Engering, Anneke; Sanchez-Hernandez, Martha; Klein, Nigel; Callard, Robin; van Putten, Jos P M; van der Ley, Peter; van Kooyk, Yvette; van de Winkel, Jan G J

    2006-02-01

    Neisseria meningitidis lipopolysaccharide (LPS) has been identified as a major determinant of dendritic cell (DC) function. Here we report that one of a series of meningococcal mutants with defined truncations in the lacto-N-neotetraose outer core of the LPS exhibited unique strong adhesion and internalization properties towards DC. These properties were mediated by interaction of the GlcNAc(beta1-3)-Gal(beta1-4)-Glc-R oligosaccharide outer core of lgtB LPS with the dendritic-cell-specific ICAM-3 grabbing non-integrin (DC-SIGN) lectin receptor. Activation of DC-SIGN with this novel oligosaccharide ligand skewed T-cell responses driven by DC towards T helper type 1 activity. Thus, the use of lgtB LPS may provide a powerful instrument to selectively induce the desired arm of the immune response and potentially increase vaccine efficacy.

  7. Using PBL to Improve Educational Outcomes and Student Satisfaction in the Teaching of DC/DC and DC/AC Converters

    Martinez-Rodrigo, Fernando; Herrero-De Lucas, Luis Carlos; de Pablo, Santiago; Rey-Boue, Alexis B.

    2017-01-01

    This paper examines the question of how to use project-based learning to increase student performance and satisfaction in a power electronics course addressing the topics of dc/dc and dc/ac converters, the assembly of a dc/dc converter, and the use of a commercial speed drive. A detailed presentation of the methodology is shown, and the results…

  8. The evolution of sexes: A specific test of the disruptive selection theory.

    da Silva, Jack

    2018-01-01

    The disruptive selection theory of the evolution of anisogamy posits that the evolution of a larger body or greater organismal complexity selects for a larger zygote, which in turn selects for larger gametes. This may provide the opportunity for one mating type to produce more numerous, small gametes, forcing the other mating type to produce fewer, large gametes. Predictions common to this and related theories have been partially upheld. Here, a prediction specific to the disruptive selection theory is derived from a previously published game-theoretic model that represents the most complete description of the theory. The prediction, that the ratio of macrogamete to microgamete size should be above three for anisogamous species, is supported for the volvocine algae. A fully population genetic implementation of the model, involving mutation, genetic drift, and selection, is used to verify the game-theoretic approach and accurately simulates the evolution of gamete sizes in anisogamous species. This model was extended to include a locus for gamete motility and shows that oogamy should evolve whenever there is costly motility. The classic twofold cost of sex may be derived from the fitness functions of these models, showing that this cost is ultimately due to genetic conflict.

  9. Electronically commutated dc motors for electric vehicles

    Maslowski, E. A.

    1981-01-01

    A motor development program to explore the feasibility of electronically commutated dc motors (also known as brushless) for electric cars is described. Two different design concepts and a number of design variations based on these concepts are discussed. One design concept is based on a permanent magnet, medium speed, machine rated at 7000 to 9000 rpm, and powered via a transistor inverter power conditioner. The other concept is based on a permanent magnet, high speed, machine rated at 22,000 to 26,000 rpm, and powered via a thyristor inverter power conditioner. Test results are presented for a medium speed motor and a high speed motor each of which have been fabricated using samarium cobalt permanent magnet material.

  10. Hierarchical Velocity Control Based on Differential Flatness for a DC/DC Buck Converter-DC Motor System

    R. Silva-Ortigoza

    2014-01-01

    Full Text Available This paper presents a hierarchical controller that carries out the angular velocity trajectory tracking task for a DC motor driven by a DC/DC Buck converter. The high level control is related to the DC motor and the low level control is dedicated to the DC/DC Buck converter; both controls are designed via differential flatness. The high level control provides a desired voltage profile for the DC motor to achieve the tracking of a desired angular velocity trajectory. Then, a low level control is designed to ensure that the output voltage of the DC/DC Buck converter tracks the voltage profile imposed by the high level control. In order to experimentally verify the hierarchical controller performance, a DS1104 electronic board from dSPACE and Matlab-Simulink are used. The switched implementation of the hierarchical average controller is accomplished by means of pulse width modulation. Experimental results of the hierarchical controller for the velocity trajectory tracking task show good performance and robustness against the uncertainties associated with different system parameters.

  11. The Topologies Research of a Soft Switching Bidirectional DC/DC Converter

    Zhang, Qi; Zhang, Yongping; Sun, Xiangdong

    2017-01-01

    A soft-switching solution implemented to the traditional bidirectional DC/DC converter is developed. The soft-switching cell, which composed of three auxiliary switches, one resonant capacitor and one resonant inductor, is equipped in the traditional bidirectional DC/DC converter to realize circuit...... circle. And the proposed topology of bidirectional soft-switching dc-dc converter(TASBC) performs ideal soft switching at boost operations. The characteristics of the proposed converter has been verified by MATLAB simulations and experimental results....

  12. Elimination of output voltage oscillations in DC-DC converter using PWM with PI controller

    Sreenivasappa Veeranna Bhupasandra

    2010-01-01

    Full Text Available In this paper the SIMULINK model of a PWM controlled DC-DC converter is modeled using switching function concept to control the speed of the DC motor. The presence of the voltage oscillation cycles due to higher switching frequency in the DC-DC converter is identified. The effect of these oscillations on the output voltage of the converter, Armature current, Developed torque and Speed of the DC motor is analyzed. In order to minimize the oscillation cycles the PI controller is proposed in the PWM controller.

  13. Chaos analysis and chaotic EMI suppression of DC-DC converters

    Zhang, Bo

    2014-01-01

    Introduces chaos theory, its analytical methods and the means to apply chaos to the switching power supply design DC-DC converters are typical switching systems which have plenty of nonlinear behaviors, such as bifurcation and chaos. The nonlinear behaviors of DC-DC converters have been studied heavily over the past 20 years, yet researchers are still unsure of the practical application of bifurcations and chaos in switching converters. The electromagnetic interference (EMI), which resulted from the high rates of changes of voltage and current, has become a major design criterion in DC-DC co

  14. Breakdown characteristics in DC spark experiments of copper focusing on purity and hardness

    Yokoyama, Kazue; Higashi, Yasuo; Higo, Toshi; Matsumoto, Shuji; Santiago-Kern, Ana Rocia; Pasquino, Chiara; Calatroni, Sergio; Wuensch, Walter

    2010-01-01

    The breakdown characteristics related to the differences in purity and hardness were investigated for several types of copper using a DC spark test system. Three types of oxygen-free copper (OFC) materials, usual class 1 OFC 7-nine large-grain copper and 6-nine hot-isotropic-pressed (HIP) copper with/without diamond finish, were tested with the DC spark test system. The measurements of the beta, breakdown fields, and breakdown probability are presented and discussed in this paper.

  15. Testing for the Occurrence of Selective Episodes During the Divergence of Otophysan Fishes: Insights from Mitogenomics.

    D'Anatro, Alejandro; Giorello, Facundo; Feijoo, Matías; Lessa, Enrique P

    2017-04-01

    How natural selection shapes biodiversity constitutes a topic of renewed interest during the last few decades. The division Otophysi comprises approximately two-thirds of freshwater fish diversity and probably underwent an extensive adaptive radiation derived from a single invasion of the supercontinent Pangaea, giving place to the evolution of the main five Otophysan lineages during a short period of time. Little is known about the factors involved in the processes that lead to lineage diversification among this group of fishes and identifying directional selection acting over protein-coding genes could offer clues about the processes acting on species diversification. The main objective of this study was to explore the otophysan mitochondrial genome evolution, in order to account for the possible signatures of selective events in this lineage, and to explore for the functional connotations of these molecular substitutions. Mainly, three different approaches were used: the "ω-based" BS-REL and MEME methods, implemented in the DATAMONKEY web server, and analysis of selection on amino acid properties, implemented in the software TreeSAAP. We found evidence of selective episodes along several branches of the evolutionary history of othophysan fishes. Analyses carried out using the BS-REL algorithm suggest episodic diversifying selection at basal branches of the otophysan lineage, which was also supported by analyses implemented in MEME and TreeSAAP. These results suggest that throughout the Siluriformes radiation, an important number of adaptive changes occurred in their mitochondrial genome. The metabolic consequences and ecological correlates of these molecular substitutions should be addressed in future studies.

  16. Cyber Selection Test Research Effort for U.S. Army New Accessions

    2017-10-12

    Sciences. Presented to International Military Testing Association 12 OCT 17 2 Purpose Army Need: To identify initial entry personnel who have the...Validation Procedure: (Administered via Paper & Pencil) Restarts - Recycles Tests: Outcomes: • ICTL / Cyber Test • JCAC grades • ASVAB – Skilled Technical...a function or purpose Systems Thinking: Understanding activity and changing characteristics of a system as it operates and the ability to

  17. Computer-controlled environmental test systems - Criteria for selection, installation, and maintenance.

    Chapman, C. P.

    1972-01-01

    Applications for presently marketed, new computer-controlled environmental test systems are suggested. It is shown that capital costs of these systems follow an exponential cost function curve that levels out as additional applications are implemented. Some test laboratory organization changes are recommended in terms of new personnel requirements, and facility modification are considered in support of a computer-controlled test system. Software for computer-controlled test systems are discussed, and control loop speed constraints are defined for real-time control functions. Suitable input and output devices and memory storage device tradeoffs are also considered.

  18. DC-STAMP Is an Osteoclast Fusogen Engaged in Periodontal Bone Resorption.

    Wisitrasameewong, W; Kajiya, M; Movila, A; Rittling, S; Ishii, T; Suzuki, M; Matsuda, S; Mazda, Y; Torruella, M R; Azuma, M M; Egashira, K; Freire, M O; Sasaki, H; Wang, C Y; Han, X; Taubman, M A; Kawai, T

    2017-06-01

    Dendritic cell-specific transmembrane protein (DC-STAMP) plays a key role in the induction of osteoclast (OC) cell fusion, as well as DC-mediated immune regulation. While DC-STAMP gene expression is upregulated in the gingival tissue with periodontitis, its pathophysiological roles in periodontitis remain unclear. To evaluate the effects of DC-STAMP in periodontitis, anti-DC-STAMP-monoclonal antibody (mAb) was tested in a mouse model of ligature-induced periodontitis ( n = 6-7/group) where Pasteurella pneumotropica ( Pp)-reactive immune response activated T cells to produce receptor activator of nuclear factor kappa-B ligand (RANKL), which, in turn, promotes the periodontal bone loss via upregulation of osteoclastogenesis. DC-STAMP was expressed on the cell surface of mature multinuclear OCs, as well as immature mononuclear OCs, in primary cultures of RANKL-stimulated bone marrow cells. Anti-DC-STAMP-mAb suppressed the emergence of large, but not small, multinuclear OCs, suggesting that DC-STAMP is engaged in the late stage of cell fusion. Anti-DC-STAMP-mAb also inhibited pit formation caused by RANKL-stimulated bone marrow cells. Attachment of ligature to a second maxillary molar induced DC-STAMP messenger RNA and protein, along with elevated tartrate-resistant acid phosphatase-positive (TRAP+) OCs and alveolar bone loss. As we expected, systemic administration of anti-DC-STAMP-mAb downregulated the ligature-induced alveolar bone loss. Importantly, local injection of anti-DC-STAMP-mAb also suppressed alveolar bone loss and reduced the total number of multinucleated TRAP+ cells in mice that received ligature attachment. Attachment of ligature induced significantly elevated tumor necrosis factor-α, interleukin-1β, and RANKL in the gingival tissue compared with the control site without ligature ( P < 0.05), which was unaffected by local injection with either anti-DC-STAMP-mAb or control-mAb. Neither in vivo anti- Pp IgG antibody nor in vitro anti- Pp T

  19. Does point-of-purchase nutrition labeling influence meal selections? A test in an Army cafeteria.

    Sproul, Allen D; Canter, Deborah D; Schmidt, Jeffrey B

    2003-07-01

    This study assessed the effectiveness of nutrition labeling on sales of targeted entrees and measured the perceived influence that factors such as taste, quality, appearance, fat content, calorie content, and price had on meal selection behavior within an Army cafeteria. A quasi-experimental design was used to compare targeted entrée sales between a 1-year baseline period and two 30-day postintervention periods, after the placement of entrée nutrition labels. A brief questionnaire, distributed to 149 patrons, measured the perceived influence of the aforementioned factors on selections. Analysis of variance detected no significant differences in sales between baseline and the two intervention periods; the factors of taste and quality were rated most influential to meal selection (p < 0.000). A marketing campaign focusing on the health attributes of targeted entrée items was not successful in boosting sales. Sensory attributes (i.e., taste, quality, and appearance) appear to be more influential to meal selection.

  20. Testing water-soluble carbohydrate QTL effects in perennial ryegrass (Lolium perenne L.) by marker selection

    Turner, L.B.; Farrell, M.; Humphreys, M.O.; Dolstra, O.

    2010-01-01

    Water-soluble carbohydrates (WSC) are an important factor determining the nutritional value of grass forage and development of genetic markers for selection of WSC traits in perennial ryegrass would benefit future breeding programmes. Quantitative trait loci (QTLs) for WSC have been published for an