WorldWideScience

Sample records for segment 2-3 graft

  1. Partial lesions of the intratemporal segment of the facial nerve: graft versus partial reconstruction.

    Science.gov (United States)

    Bento, Ricardo F; Salomone, Raquel; Brito, Rubens; Tsuji, Robinson K; Hausen, Mariana

    2008-09-01

    In cases of partial lesions of the intratemporal segment of the facial nerve, should the surgeon perform an intraoperative partial reconstruction, or partially remove the injured segment and place a graft? We present results from partial lesion reconstruction on the intratemporal segment of the facial nerve. A retrospective study on 42 patients who presented partial lesions on the intratemporal segment of the facial nerve was performed between 1988 and 2005. The patients were divided into 3 groups based on the procedure used: interposition of the partial graft on the injured area of the nerve (group 1; 12 patients); keeping the preserved part and performing tubulization (group 2; 8 patients); and dividing the parts of the injured nerve (proximal and distal) and placing a total graft of the sural nerve (group 3; 22 patients). Fracture of the temporal bone was the most frequent cause of the lesion in all groups, followed by iatrogenic causes (p lesion of the facial nerve is still questionable. Among these 42 patients, the best results were those from the total graft of the facial nerve.

  2. Transforaminal lumbar interbody graft placement using an articulating delivery arm facilitates increased segmental lordosis with superior anterior and midline graft placement.

    Science.gov (United States)

    Shau, David N; Parker, Scott L; Mendenhall, Stephen K; Zuckerman, Scott L; Godil, Saniya S; Devin, Clinton J; McGirt, Matthew J

    2015-05-01

    Transforaminal lumbar interbody fusion (TLIF) is a frequently performed method of lumbar arthrodesis in patients failing medical management of back and leg pain. Accurate placement of the interbody graft and restoration of lordosis has been shown to be crucial when performing lumbar fusion procedures. We performed a single-surgeon, prospective, randomized study to determine whether a novel articulating versus traditional straight graft delivery arm system allows for superior graft placement and increased lordosis for single-level TLIF. Thirty consecutive patients undergoing single-level TLIF were included and prospectively randomized to one of the 2 groups (articulated vs. straight delivery arm system). Three radiographic characteristics were evaluated at 6-week follow-up: (1) degree of segmental lumbar lordosis at the fused level; (2) the percent anterior location of the interbody graft in disk space; and (3) the distance (mm) off midline of the interbody graft placement. Randomization yielded 16 patients in the articulated delivery arm cohort and 14 in the straight delivery arm cohort. The articulating delivery arm system yielded an average of 14.7-degree segmental lordosis at fused level, 35% anterior location, and 3.6 mm off midline. The straight delivery arm system yielded an average of 10.7-degree segmental lordosis at fused level, 46% anterior location, and 7.0 mm off midline. All 3 comparisons were statistically significant (Plordosis compared with a traditional straight delivery arm system.

  3. The γ-radiation induced grafting of unsaturated segmented polyurethanes with N-vinyl pyrrolidone

    International Nuclear Information System (INIS)

    Egboh, S.H.; George, M.H.; Barrie, J.A.

    1984-01-01

    Linear unsaturated segmented polyurethanes have been modified by hydrophilic grafting at 40 deg C with N-vinyl pyrrolidone, in N,N-dimethylformamide as solvent, using 60 Cobalt γ-irradiation. Graft copolymers were isolated from homopolymers by selective solvent extraction using a Soxhlet apparatus. The effects of reaction time, total dose, temperature and monomer concentration, on the graft yields have been examined. Relatively high irradiation doses were avoided during the grafting experiments to prevent possible degradation of the segmented polyurethanes and gelation of the homopolymer, poly(N-vinyl pyrrolidone). The ungrafted and grafted copolymers were characterized, and the graft copolymers were shown to be more thermally stable than the original polyurethanes, by thermogravimetric analysis. An explanation for the observed variation of the graft yields with some of the experimental variables is suggested. (author)

  4. Regeneration of Surgically Excised Segments of Dog Esophagus using Biodegradable PLA Hollow Organ Grafts,

    Science.gov (United States)

    1980-06-01

    7 AG 396 ARMY INST OF DENTAL RESEARCH WASHINGTON DC FIG 6/5 REGENERATION OF SURGICALLY EXCISED SEGMENTS OF DOG ESOPHAGUS US-ETC(W) U15 G’OE UN8 N F...the graft; infection; inadequate blood supply; difficulties in suture retention; leakage at the anastomatic sites; stenosis of the anasto- mosis...excised segment of the dog esophagus. On a conceptual L- J basis, the use of a biodegradable polymer to fabricate a successful J hollow organ graft holds

  5. Segmentation of skin lesions in chronic graft versus host disease photographs with fully convolutional networks

    Science.gov (United States)

    Wang, Jianing; Chen, Fuyao; Dellalana, Laura E.; Jagasia, Madan H.; Tkaczyk, Eric R.; Dawant, Benoit M.

    2018-02-01

    Chronic graft-versus-host disease (cGVHD) is a frequent and potentially life-threatening complication of allogeneic hematopoietic stem cell transplantation (HCT) and commonly affects the skin, resulting in distressing patient morbidity. The percentage of involved body surface area (BSA) is commonly used for diagnosing and scoring the severity of cGVHD. However, the segmentation of the involved BSA from patient whole body serial photography is challenging because (1) it is difficult to design traditional segmentation method that rely on hand crafted features as the appearance of cGVHD lesions can be drastically different from patient to patient; (2) to the best of our knowledge, currently there is no publicavailable labelled image set of cGVHD skin for training deep networks to segment the involved BSA. In this preliminary study we create a small labelled image set of skin cGVHD, and we explore the possibility to use a fully convolutional neural network (FCN) to segment the skin lesion in the images. We use a commercial stereoscopic Vectra H1 camera (Canfield Scientific) to acquire 400 3D photographs of 17 cGVHD patients aged between 22 and 72. A rotational data augmentation process is then applied, which rotates the 3D photos through 10 predefined angles, producing one 2D projection image at each position. This results in 4000 2D images that constitute our cGVHD image set. A FCN model is trained and tested using our images. We show that our method achieves encouraging results for segmenting cGVHD skin lesion in photographic images.

  6. Bone grafting with granular biomaterial in segmental maxillary osteotomy: A case report

    Directory of Open Access Journals (Sweden)

    Orion Luiz Haas Junior

    2016-01-01

    Conclusion: This is the first report of bone grafting with a granular biomaterial in segmental maxillary osteotomy. Successful formation of new bone with density greater than that of the surrounding tissue was achieved, preventing pseudarthrosis and postoperative instability.

  7. Impact of contrast injection and stent-graft implantation on reproducibility of volume measurements in semiautomated segmentation of abdominal aortic aneurysm on computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Morin-Roy, Florence; Hadjadj, Sofiane; Thomas, Olivier; Yang, Dan Yang [Centre Hospitalier Universitaire de Montreal (CHUM), Hopital Notre-Dame, Department of Radiology, Montreal, Quebec (Canada); Kauffmann, Claude [University of Montreal, Centre de Recherche, Centre Hospitalier Universitaire de Montreal (CRCHUM), Montreal, Quebec (Canada); Tang, An [University of Montreal, Centre de Recherche, Centre Hospitalier Universitaire de Montreal (CRCHUM), Montreal, Quebec (Canada); Centre Hospitalier Universitaire de Montreal (CHUM), Hopital Saint-Luc, Department of Radiology, Montreal, Quebec (Canada); Piche, Nicolas [Object Research System, Montreal, Quebec (Canada); Elkouri, Stephane [Centre Hospitalier Universitaire de Montreal (CHUM), Hopital Hotel-Dieu, Department of Vascular surgery, Montreal, Quebec (Canada); Therasse, Eric [University of Montreal, Centre de Recherche, Centre Hospitalier Universitaire de Montreal (CRCHUM), Montreal, Quebec (Canada); Centre Hospitalier Universitaire de Montreal (CHUM), Hopital Hotel-Dieu, Department of Radiology, Montreal, Quebec (Canada); Soulez, Gilles [Centre Hospitalier Universitaire de Montreal (CHUM), Hopital Notre-Dame, Department of Radiology, Montreal, Quebec (Canada); University of Montreal, Centre de Recherche, Centre Hospitalier Universitaire de Montreal (CRCHUM), Montreal, Quebec (Canada)

    2014-07-15

    To assess the impact of contrast injection and stent-graft implantation on feasibility, accuracy, and reproducibility of abdominal aortic aneurysm (AAA) volume and maximal diameter (D-max) measurements using segmentation software. CT images of 80 subjects presenting AAA were divided into four equal groups: with or without contrast enhancement, and with or without stent-graft implantation. Semiautomated software was used to segment the aortic wall, once by an expert and twice by three readers. Volume and D-max reproducibility was estimated by intraclass correlation coefficients (ICC), and accuracy was estimated between the expert and the readers by mean relative errors. All segmentations were technically successful. The mean AAA volume was 167.0 ± 82.8 mL and the mean D-max 55.0 ± 10.6 mm. Inter- and intraobserver ICCs for volume and D-max measurements were greater than 0.99. Mean relative errors between readers varied between -1.8 ± 4.6 and 0.0 ± 3.6 mL. Mean relative errors in volume and D-max measurements between readers showed no significant difference between the four groups (P ≥ 0.2). The feasibility, accuracy, and reproducibility of AAA volume and D-max measurements using segmentation software were not affected by the absence of contrast injection or the presence of stent-graft. (orig.)

  8. Coronary artery bypass grafts: assessment of graft patency and native coronary artery lesions using 16-slice MDCT

    Energy Technology Data Exchange (ETDEWEB)

    Stauder, Norbert I.; Drosch, Tanja; Claussen, Claus D.; Kopp, Andreas F. [Eberhard-Karls-University, Department of Diagnostic Radiology, Tuebingen (Germany); Kuettner, Axel [Friedrich-Alexander-University, Department of Diagnostic Radiology, Erlangen (Germany); Schroeder, Stephen; Beck, Torsten [Eberhard-Karls-University, Department of Internal Medicine, Division Cardiology, Tuebingen (Germany); Stauder, Heidrun [Eberhard-Karls-University, Department of Thoracic and Cardiovascular Surgery, Tuebingen (Germany); Blumenstock, Gunnar [Eberhard-Karls-University, Department of Medical Information Processing, Tuebingen (Germany)

    2006-11-15

    The objective of this study was to evaluate the accuracy of electrocardiography (ECG)-gated 16-slice multidetector-row computed tomography (MDCT) in detection of stenosis of bypass grafts and native coronary arteries in patients who have undergone coronary artery bypass grafting (CABG). ECG-gated contrast-enhanced MDCT using 12 x 0.75-mm collimation was performed in 20 patients with recurrent angina 4.75 years after undergoing CABG. A total of 50 grafts, 16 arterial and 34 venous, were examined. All graft and coronary segments were evaluated for stenosis in comparison with conventional coronary angiography (CCA). Among the 80 arterial graft segments, 62 could be assessed (77.5%). Sensitivity, specificity, and positive and negative predictive values for stenosis were 96.2%, 97.2%, 96.2%, and 97.2%, respectively. In a total of 180 venous graft segments, 167 could be assessed. Sensitivity, specificity, and positive and negative predictive values for stenosis were 98.5%, 93.9%, 91.8%, and 98.9%, respectively. MDCT could assess 179 of 260 native coronary artery segments (68.8%).Sensitivity, specificity, and positive and negative predictive values for stenosis were 92.1%, 76.9%, 87.5%, and 84.7%, respectively. Sixteen-slice MDCT provides excellent image quality and diagnostic accuracy in detection of graft and coronary artery lesions in patients with suspected graft dysfunction. (orig.)

  9. Treatment of ankylosed maxillary central incisors by segmental osteotomy with autogenous bone graft.

    Science.gov (United States)

    You, Kug-Ho; Min, Yon-Sook; Baik, Hyoung-Seon

    2012-04-01

    This case report describes the treatment of a 16-year-old girl with ankylosed maxillary central incisors that were noticeably infraoccluded and labially displaced. We performed a segmental osteotomy with an autogenous bone graft in a single-stage surgery to align and level the ankylosed teeth. The dento-osseous segment was successfully repositioned with satisfactory periodontal results. Copyright © 2012 American Association of Orthodontists. Published by Mosby, Inc. All rights reserved.

  10. Abscisic Acid-Induced H2O2 Accumulation Enhances Antioxidant Capacity in Pumpkin-Grafted Cucumber Leaves under Ca(NO3)2 Stress

    Science.gov (United States)

    Shu, Sheng; Gao, Pan; Li, Lin; Yuan, Yinghui; Sun, Jin; Guo, Shirong

    2016-01-01

    With the aim to clarifying the role of the ABA/H2O2 signaling cascade in the regulating the antioxidant capacity of grafted cucumber plants in response to Ca(NO3)2 stress, we investigated the relationship between ABA-mediated H2O2 production and the activities of antioxidant enzymes in the leaves of pumpkin-grafted cucumber seedlings. The results showed that both ABA and H2O2 were detected in pumpkin-grafted cucumber seedlings in response to Ca(NO3)2 treatment within 0.5 h in the leaves and peaked at 3 and 6 h after Ca(NO3)2 treatment, respectively, compared to the levels under control conditions. The activities of superoxide dismutase (SOD), ascorbate peroxidase (APX), and peroxidase (POD) in pumpkin-grafted cucumber leaves gradually increased over time and peaked at 12 h of Ca(NO3)2 stress. Furthermore, in the leaves of pumpkin-grafted cucumber seedlings, the H2O2 generation, the antioxidant enzyme activities and the expression of SOD, POD and cAPX were strongly blocked by an inhibitor of ABA under Ca(NO3)2 stress, but this effect was eliminated by the addition of exogenous ABA. Moreover, the activities and gene expressions of these antioxidant enzymes in pumpkin-grafted leaves were almost inhibited under Ca(NO3)2 stress by pretreatment with ROS scavengers. These results suggest that the pumpkin grafting-induced ABA accumulation mediated H2O2 generation, resulting in the induction of antioxidant defense systems in leaves exposed to Ca(NO3)2 stress in the ABA/H2O2 signaling pathway. PMID:27746808

  11. Evaluation of temporal windows for coronary artery bypass graft imaging with 64-slice CT

    International Nuclear Information System (INIS)

    Desbiolles, Lotus; Leschka, Sebastian; Scheffel, Hans; Husmann, Lars; Garzoli, Elisabeth; Marincek, Borut; Alkadhi, Hatem; Plass, Andre; Gaemperli, Oliver; Kaufmann, Philipp A.

    2007-01-01

    Temporal windows providing the best image quality of different segments and types of coronary artery bypass grafts (CABGs) with 64-slice computed tomography (CT) were evaluated in an experimental set-up. Sixty-four-slice CT with a rotation time of 330 ms was performed in 25 patients (four female; mean age 59.9 years). A total of 84 CABGs (62 individual and 22 sequential grafts) were evaluated, including 28 internal mammary artery (33.3%), one radial artery with sequential grafting (2.4%), and 54 saphenous vein grafts (64.3%). Ten data sets were reconstructed in 10% increments of the RR-interval. Each graft was separated into segments (proximal and distal anastomosis, and body), and CABG types were grouped according to target arteries. Two readers independently assessed image quality of each CABG segment in each temporal window. Diagnostic image quality was found with good inter-observer agreement (kappa=0.62) in 98.5% (202/205) of all graft segments. Image quality was significantly better for saphenous vein grafts versus arterial grafts (P<0.001) and for distal anastomosis to the right coronary compared with other target coronary arteries (P<0.05). Overall, best image quality was found at 60%. Image quality of proximal segments did not significantly vary with the temporal window, whereas for all other segments image quality was significantly better at 60% compared with other temporal windows (P<0.05). Sixty-four-slice CT provides best image quality of various segments and types of CABG at 60% of the RR-interval. (orig.)

  12. Vascular Biocompatibility of a Triple Layered Self Expanding Stent-Graft in a Dog Mode

    Energy Technology Data Exchange (ETDEWEB)

    Bae, Jae Ik; Won, Je Hwan; Jang, Eun Ho; Lee, Sung Yeong; Ko, Kwang Tae [Dept. of Radiology, Ajou University School of Medicine, Suwon (Korea, Republic of); Jin, Bo Hwan [Medical Science Research Center, Ajou University School of Medicine, Suwon (Korea, Republic of); Lee, June Woo [Dept. of Radiology, Busan National University College of Medicine, Busan (Korea, Republic of)

    2012-02-15

    To evaluate performance and biocompatibility of a newly designed self-expanding stent graft, which consisted of two nitinol stents and an intervening expanded polytetrafluoroethylene membrane in a dog artery model. Twelve stent grafts were placed in the aorta of 6 dogs (beagle, mean body weight 11 kg) for 4 weeks (n = 4) and 12 weeks (n = 8). Luminal diameters were measured for each segment (the proximal bare, the middle graft, the distal bare) by angiographies after implantation and follow up periods. Percent luminal stenosis based on angiographies, histomorphometric, histologic, and scanning electron microscopic analyses of each segments were performed. Blood flow through the stent grafts was good after implantation and during the follow up period, without thrombotic occlusion or stent graft migration. The mean percent luminal stenosis of the proximal bare, the middle grafted and the distal bare segments after 12 weeks were 13.5%, 3.9%, 9.6% retrospectively. The mean neointimal areas of the middle grafted segment were 4.39 mm{sup 2} (4 week) and 4.92 mm{sup 2} (12 week). Mature endothelialization was evident in over 70% of the area of the stented artery after 4 weeks and in over 90% after 12 weeks. The stent graft was well placed in the attempted area without migration. During the 12-week-follow up period, it showed a good patency without thrombotic occlusion or significant in-stent luminal stenosis. Endothelialization was rapid and nearly complete. Neointima was thin and smooth on the middle graft segment and thicker and irregular on the bare segments.

  13. Vascular Biocompatibility of a Triple Layered Self Expanding Stent-Graft in a Dog Mode

    International Nuclear Information System (INIS)

    Bae, Jae Ik; Won, Je Hwan; Jang, Eun Ho; Lee, Sung Yeong; Ko, Kwang Tae; Jin, Bo Hwan; Lee, June Woo

    2012-01-01

    To evaluate performance and biocompatibility of a newly designed self-expanding stent graft, which consisted of two nitinol stents and an intervening expanded polytetrafluoroethylene membrane in a dog artery model. Twelve stent grafts were placed in the aorta of 6 dogs (beagle, mean body weight 11 kg) for 4 weeks (n = 4) and 12 weeks (n = 8). Luminal diameters were measured for each segment (the proximal bare, the middle graft, the distal bare) by angiographies after implantation and follow up periods. Percent luminal stenosis based on angiographies, histomorphometric, histologic, and scanning electron microscopic analyses of each segments were performed. Blood flow through the stent grafts was good after implantation and during the follow up period, without thrombotic occlusion or stent graft migration. The mean percent luminal stenosis of the proximal bare, the middle grafted and the distal bare segments after 12 weeks were 13.5%, 3.9%, 9.6% retrospectively. The mean neointimal areas of the middle grafted segment were 4.39 mm 2 (4 week) and 4.92 mm 2 (12 week). Mature endothelialization was evident in over 70% of the area of the stented artery after 4 weeks and in over 90% after 12 weeks. The stent graft was well placed in the attempted area without migration. During the 12-week-follow up period, it showed a good patency without thrombotic occlusion or significant in-stent luminal stenosis. Endothelialization was rapid and nearly complete. Neointima was thin and smooth on the middle graft segment and thicker and irregular on the bare segments.

  14. Lithium storage study on MoO3-grafted TiO2 nanotube arrays

    Directory of Open Access Journals (Sweden)

    Tauseef Anwar

    2016-03-01

    Full Text Available Abstract Titanium dioxide nanotube arrays (TNAs were fabricated via anodic ionization. Porous MoO3 was grafted on TNAs with the help of hydrothermal method. Scanning electron microscopy and X-ray powder diffraction was utilized for the confirmation of one dimensional morphology and phase identification. The porous MoO3 nanoflake-grafted TNAs (MoO3/TNAs electrode was used as anode material in lithium ion battery (LIB and it was found that the areal specific capacity of MoO3/TNAs (~797 µAh cm−2 was three times higher than those of anatase TNAs (~287 µAh cm−2 and porous MoO3 (~234 µAh cm−2 at 50 µA cm−2.

  15. Coating of Dacron vascular grafts with an ionic polyurethane: a novel sealant with protein binding properties.

    Science.gov (United States)

    Phaneuf, M D; Dempsey, D J; Bide, M J; Quist, W C; LoGerfo, F W

    2001-03-01

    The purpose of this study was to develop a novel sealant that would seal prosthetic vascular graft interstices and be accessible for protein binding. Crimped knitted Dacron vascular grafts were cleaned (CNTRL) and hydrolyzed in boiling sodium hydroxide (HYD). These HYD grafts were sealed using an 11% solids solution of a polyether-based urethane with carboxylic acid groups (PEU-D) via a novel technique that employs both trans-wall and luminal perfusion. Carboxylic acid content, determined via methylene blue dye uptake, was 2.3- and 4.2-fold greater in PEU-D segments (1.0+/-0.27 nmol/mg) as compared to HYD and CNTRL segments, respectively. Water permeation through PEU-D graft (1.1+/-2 ml/cm2 min(-1)) was comparable to collagen-impregnated Dacron (9.8+/-10 ml/cm2 min(-1)). Non-specific 125I-albumin (125I-Alb) binding to PEU-D segments (18+/-3 ng/mg) was significantly lower than HYD and CNTRL segments. 125I-Alb linkage to PEU-D using the crosslinker EDC resulted in 5.7-fold greater binding (103+/-2 ng/mg) than non-specific PEU-D controls. However, covalent linkage of 125I-Alb to PEU-D was 4.9- and 5.9-fold less than CNTRL and HYD segments with EDC, respectively. Thus, ionic polyurethane can be applied to a pre-formed vascular graft, seal the interstices and create "anchor" sites for protein attachment.

  16. Effects of grafting with pumpkin rootstock on carbohydrate metabolism in cucumber seedlings under Ca(NO3)2 stress.

    Science.gov (United States)

    Xing, Wen-wen; Li, Lin; Gao, Pan; Li, He; Shao, Qiao-sai; Shu, Sheng; Sun, Jin; Guo, Shi-rong

    2015-02-01

    This study investigated the effects of grafting on the carbohydrate status and the enzymes of carbohydrate metabolism in self-grafted and grafted cucumber seedlings using the salt-tolerant pumpkin rootstock 'Qingzhen 1' (Cucurbita maxima × Cucurbita moschata) under 80 mM Ca(NO3)2 stress for 6 d. The growth of self-grafted seedlings was significantly inhibited after the treatment of Ca(NO3)2 stress, whereas the inhibition of growth was alleviated in pumpkin rootstock-grafted seedlings. Ca(NO3)2 stress increased the contents of the total soluble sugar, sucrose and fructose, but decreased the starch content in rootstock-grafted leaves. However, compared with self-grafted plants, rootstock-grafted seedlings were observed with a higher content of sucrose and total soluble sugar (TSS) under salt stress. Rootstock-grafted seedlings exhibited higher activities of acid invertase (AI), neutral invertase (NI) and phosphate sucrose synthase (SPS) of sucrose metabolism in leaves than that of self-grafted seedlings under salinity. Moreover, the activities of fructokinase (FK), hexokinase (HK), phosphofructokinase (PFK) and pyruvate kinase (PK) of glycolysis were maintained at a higher level in leaves of rootstock-grafted seedlings after Ca(NO3)2 stress. Additionally, rootstock-grafting decrease the high percentage enhancement of key enzymes gene expression in glycolysis in the scion leaves of cucumber seedlings induced by salt stress. These results suggest that the rootstock-grafting improved salt tolerance, which might play a role in elevated sucrose metabolism and a glycolytic pathway regulated by the pumpkin rootstock. Copyright © 2015 Elsevier Masson SAS. All rights reserved.

  17. [Bone graft reconstruction for posterior mandibular segment using the formwork technique].

    Science.gov (United States)

    Pascual, D; Roig, R; Chossegros, C

    2014-04-01

    Pre-implant bone graft in posterior mandibular segments is difficult because of masticatory and lingual mechanical constraints, because of the limited bone vascularization, and because of the difficulty to cover it with the mucosa. The formwork technique is especially well adapted to this topography. The recipient site is abraded with a drill. Grooves are created to receive and stabilize the grafts. The bone grafts were harvested from the ramus. The thinned cortices are assembled in a formwork and synthesized by mini-plates. The gaps are filled by bone powder collected during bone harvesting. The bone volume reconstructed with the formwork technique allows anchoring implants more than 8mm long. The proximity of the inferior alveolar nerve does not contra indicate this technique. The formwork size and its positioning on the alveolar crest can be adapted to prosthetic requirements by using osteosynthesis plates. The lateral implant walls are supported by the formwork cortices; the implant apex is anchored on the native alveolar crest. The primary stability of implants is high, and the torque is important. The ramus harvesting decreases operative risks. Copyright © 2014 Elsevier Masson SAS. All rights reserved.

  18. Diagnostic value of myocardial perfusion SPECT in the prediction of restenosis after coronary artery bypass graft surgery

    International Nuclear Information System (INIS)

    Paeng, J. C.; Lee, D. S.; Kang, W. J.; Kim, K. B.; Chung, J. K.; Lee, M. C.

    2002-01-01

    Myocardial SPECT has been reported to be sensitive in the detection of restenosis after revascularization. However, the diagnostic value is not well established in bypass graft surgery (CABG), due to significant influences of characteristics of graft vessels and the time interval between CABG and the SPECT. In this study, we evaluated the diagnostic value of myocardial SPECT for the restenosis after CABG. A total of 160 patients with coronary artery disease (M:F=118:42, 60±8 yr) who had undergone CABG were included. Rest T1-201/ dipyridamole stress Tc-99m-MIBI SPECT was performed 3 months (103±16 days) after CABG. Segmental perfusion was quantified using a 20-segment model, and segments of reversible perfusion defect (REV) were defined. Follow-up coronary angiography was performed 1 year (397±104 days) after CABG. The segments of REV were compared between arterial and venous graft groups. And the diagnostic power of 3-month SPECT was evaluated for the prediction of restenosis. On the 3-month SPECT, 620 segments showed REV. The segments of REV were 37% of artery-grafted segments and 36% of vein-grafted segments (p=n.s.). On 1-year coronary angiography, 113 graft vessels (28%) showed restenosis. The overall sensitivity and specificity of REV on 3-month SPECT for the prediction of restenosis were 46% and 67%, respectively, but 52% and 68%, in artery-graft group. REV detected on 3-month SPECT has a predictive value, especially, high specificity for the prediction of restenosis after CABG, which was more definite in artery-graft group

  19. A 2D driven 3D vessel segmentation algorithm for 3D digital subtraction angiography data

    International Nuclear Information System (INIS)

    Spiegel, M; Hornegger, J; Redel, T; Struffert, T; Doerfler, A

    2011-01-01

    Cerebrovascular disease is among the leading causes of death in western industrial nations. 3D rotational angiography delivers indispensable information on vessel morphology and pathology. Physicians make use of this to analyze vessel geometry in detail, i.e. vessel diameters, location and size of aneurysms, to come up with a clinical decision. 3D segmentation is a crucial step in this pipeline. Although a lot of different methods are available nowadays, all of them lack a method to validate the results for the individual patient. Therefore, we propose a novel 2D digital subtraction angiography (DSA)-driven 3D vessel segmentation and validation framework. 2D DSA projections are clinically considered as gold standard when it comes to measurements of vessel diameter or the neck size of aneurysms. An ellipsoid vessel model is applied to deliver the initial 3D segmentation. To assess the accuracy of the 3D vessel segmentation, its forward projections are iteratively overlaid with the corresponding 2D DSA projections. Local vessel discrepancies are modeled by a global 2D/3D optimization function to adjust the 3D vessel segmentation toward the 2D vessel contours. Our framework has been evaluated on phantom data as well as on ten patient datasets. Three 2D DSA projections from varying viewing angles have been used for each dataset. The novel 2D driven 3D vessel segmentation approach shows superior results against state-of-the-art segmentations like region growing, i.e. an improvement of 7.2% points in precision and 5.8% points for the Dice coefficient. This method opens up future clinical applications requiring the greatest vessel accuracy, e.g. computational fluid dynamic modeling.

  20. Polyether/Polyester Graft Copolymers

    Science.gov (United States)

    Bell, Vernon L., Jr.; Wakelyn, N.; Stoakley, D. M.; Proctor, K. M.

    1986-01-01

    Higher solvent resistance achieved along with lower melting temperature. New technique provides method of preparing copolymers with polypivalolactone segments grafted onto poly (2,6-dimethyl-phenylene oxide) backbone. Process makes strong materials with improved solvent resistance and crystalline, thermally-reversible crosslinks. Resulting graft copolymers easier to fabricate into useful articles, including thin films, sheets, fibers, foams, laminates, and moldings.

  1. Hemodynamic analysis of sequential graft from right coronary system to left coronary system.

    Science.gov (United States)

    Wang, Wenxin; Mao, Boyan; Wang, Haoran; Geng, Xueying; Zhao, Xi; Zhang, Huixia; Xie, Jinsheng; Zhao, Zhou; Lian, Bo; Liu, Youjun

    2016-12-28

    Sequential and single grafting are two surgical procedures of coronary artery bypass grafting. However, it remains unclear if the sequential graft can be used between the right and left coronary artery system. The purpose of this paper is to clarify the possibility of right coronary artery system anastomosis to left coronary system. A patient-specific 3D model was first reconstructed based on coronary computed tomography angiography (CCTA) images. Two different grafts, the normal multi-graft (Model 1) and the novel multi-graft (Model 2), were then implemented on this patient-specific model using virtual surgery techniques. In Model 1, the single graft was anastomosed to right coronary artery (RCA) and the sequential graft was adopted to anastomose left anterior descending (LAD) and left circumflex artery (LCX). While in Model 2, the single graft was anastomosed to LAD and the sequential graft was adopted to anastomose RCA and LCX. A zero-dimensional/three-dimensional (0D/3D) coupling method was used to realize the multi-scale simulation of both the pre-operative and two post-operative models. Flow rates in the coronary artery and grafts were obtained. The hemodynamic parameters were also showed, including wall shear stress (WSS) and oscillatory shear index (OSI). The area of low WSS and OSI in Model 1 was much less than that in Model 2. Model 1 shows optimistic hemodynamic modifications which may enhance the long-term patency of grafts. The anterior segments of sequential graft have better long-term patency than the posterior segments. With rational spatial position of the heart vessels, the last anastomosis of sequential graft should be connected to the main branch.

  2. NO accumulation alleviates H2 O2 -dependent oxidative damage induced by Ca(NO3 )2 stress in the leaves of pumpkin-grafted cucumber seedlings.

    Science.gov (United States)

    Li, Lin; Shu, Sheng; Xu, Qing; An, Ya-Hong; Sun, Jin; Guo, Shi-Rong

    2017-05-01

    Nitric oxide (NO) and hydrogen peroxide (H 2 O 2 ), two important signaling molecules, are stimulated in plants by abiotic stresses. In this study, we investigated the role of NO and its interplay with H 2 O 2 in the response of self-grafted (S-G) and salt-tolerant pumpkin-grafted (Cucurbita maxima × C. moschata) cucumber seedlings to 80 mM Ca(NO 3 ) 2 stress. Endogenous NO and H 2 O 2 production in S-G seedlings increased in a time-dependent manner, reaching maximum levels after 24 h of Ca(NO 3 ) 2 stress. In contrast, a transient increase in NO production, accompanied by H 2 O 2 accumulation, was observed at 2 h in rootstock-grafted plants. N w -Nitro-l-Arg methyl ester hydrochloride (l-NAME), an inhibitor of nitric oxide synthase (NOS), tungstate, an inhibitor of nitrate reductase (NR), and 2-(4-carboxyphenyl)-4,4,5,5-tetramethy-limidazoline-1-oxyl-3-oxide (cPTIO), a scavenger of NO, were found to significantly inhibit NO accumulation induced by salt stress in rootstock-grafted seedlings. H 2 O 2 production was unaffected by these stress conditions. Ca(NO 3 ) 2 stress-induced NO accumulation was blocked by pretreatment with an H 2 O 2 scavenger (dimethylthiourea, DMTU) and an inhibitor of NADPH oxidase (diphenyleneiodonium, DPI). In addition, maximum quantum yield of PSII (Fv/Fm), as well as the activities and transcript levels of antioxidant enzymes, were significantly decreased by salt stress in rootstock grafted seedlings after pretreatment with these above inhibitors; antioxidant enzyme transcript levels and activities were higher in rootstock-grafted seedlings compared with S-G seedlings. These results suggest that rootstock grafting could alleviate the oxidative damage induced by Ca(NO 3 ) 2 stress in cucumber seedlings, an effect that may be attributable to the involvement of NO in H 2 O 2 -dependent antioxidative metabolism. © 2016 Scandinavian Plant Physiology Society.

  3. Pnrc2 regulates 3'UTR-mediated decay of segmentation clock-associated transcripts during zebrafish segmentation.

    Science.gov (United States)

    Gallagher, Thomas L; Tietz, Kiel T; Morrow, Zachary T; McCammon, Jasmine M; Goldrich, Michael L; Derr, Nicolas L; Amacher, Sharon L

    2017-09-01

    Vertebrate segmentation is controlled by the segmentation clock, a molecular oscillator that regulates gene expression and cycles rapidly. The expression of many genes oscillates during segmentation, including hairy/Enhancer of split-related (her or Hes) genes, which encode transcriptional repressors that auto-inhibit their own expression, and deltaC (dlc), which encodes a Notch ligand. We previously identified the tortuga (tor) locus in a zebrafish forward genetic screen for genes involved in cyclic transcript regulation and showed that cyclic transcripts accumulate post-splicing in tor mutants. Here we show that cyclic mRNA accumulation in tor mutants is due to loss of pnrc2, which encodes a proline-rich nuclear receptor co-activator implicated in mRNA decay. Using an inducible in vivo reporter system to analyze transcript stability, we find that the her1 3'UTR confers Pnrc2-dependent instability to a heterologous transcript. her1 mRNA decay is Dicer-independent and likely employs a Pnrc2-Upf1-containing mRNA decay complex. Surprisingly, despite accumulation of cyclic transcripts in pnrc2-deficient embryos, we find that cyclic protein is expressed normally. Overall, we show that Pnrc2 promotes 3'UTR-mediated decay of developmentally-regulated segmentation clock transcripts and we uncover an additional post-transcriptional regulatory layer that ensures oscillatory protein expression in the absence of cyclic mRNA decay. Copyright © 2017 Elsevier Inc. All rights reserved.

  4. Reconstruction of incomplete cell paths through a 3D-2D level set segmentation

    Science.gov (United States)

    Hariri, Maia; Wan, Justin W. L.

    2012-02-01

    Segmentation of fluorescent cell images has been a popular technique for tracking live cells. One challenge of segmenting cells from fluorescence microscopy is that cells in fluorescent images frequently disappear. When the images are stacked together to form a 3D image volume, the disappearance of the cells leads to broken cell paths. In this paper, we present a segmentation method that can reconstruct incomplete cell paths. The key idea of this model is to perform 2D segmentation in a 3D framework. The 2D segmentation captures the cells that appear in the image slices while the 3D segmentation connects the broken cell paths. The formulation is similar to the Chan-Vese level set segmentation which detects edges by comparing the intensity value at each voxel with the mean intensity values inside and outside of the level set surface. Our model, however, performs the comparison on each 2D slice with the means calculated by the 2D projected contour. The resulting effect is to segment the cells on each image slice. Unlike segmentation on each image frame individually, these 2D contours together form the 3D level set function. By enforcing minimum mean curvature on the level set surface, our segmentation model is able to extend the cell contours right before (and after) the cell disappears (and reappears) into the gaps, eventually connecting the broken paths. We will present segmentation results of C2C12 cells in fluorescent images to illustrate the effectiveness of our model qualitatively and quantitatively by different numerical examples.

  5. Descemet Stripping Automated Endothelial Keratoplasty for Failed Penetrating Keratoplasty: Influence of the Graft-Host Junction on the Graft Survival Rate.

    Science.gov (United States)

    Omoto, Takashi; Sakisaka, Toshihiro; Toyono, Tetsuya; Yoshida, Junko; Shirakawa, Rika; Miyai, Takashi; Yamagami, Satoru; Usui, Tomohiko

    2018-04-01

    To investigate the clinical results of Descemet stripping automated endothelial keratoplasty (DSAEK) for failed penetrating keratoplasty (PK) and the influence of the graft-host junction (GHJ) on the graft survival rate. Data were retrospectively collected on patient demographics, visual outcomes, complications, and graft survival rate for 17 eyes of 16 patients who underwent DSAEK for failed PK. The graft survival rate was compared between the eyes when divided into a bump group and a well-aligned group according to the shape of the GHJ detected on anterior segment optical coherence tomography. The most common indication for initial PK was bullous keratopathy after glaucoma surgery (35.3%). Seven eyes (41.2%) were classified into the bump group and 10 eyes (58.8%) into the well-aligned group. The mean best-ever documented visual acuity (BDVA) after DSAEK was 0.33 logMAR. Postoperatively, almost 70% of eyes achieved a BDVA that was within 0.2 logMAR of their preoperative BDVA. Graft detachment occurred in 29.4% of eyes and primary graft failure in 17.6%. All primary failures occurred in the bump group. The cumulative graft survival rate was 82.3% at 1 year, 73.2% at 2 years, and 58.6% at 3 years. Graft failure was more likely in eyes in the bump group than in those in the well-aligned group (P = 0.037, Wilcoxon test). DSAEK for failed PK had a favorable outcome in this study. However, the GHJ should be assessed carefully before performing the procedure.

  6. 3D Stereoscopic Visualization of Fenestrated Stent Grafts

    International Nuclear Information System (INIS)

    Sun Zhonghua; Squelch, Andrew; Bartlett, Andrew; Cunningham, Kylie; Lawrence-Brown, Michael

    2009-01-01

    The purpose of this study was to present a technique of stereoscopic visualization in the evaluation of patients with abdominal aortic aneurysm treated with fenestrated stent grafts compared with conventional 2D visualizations. Two patients with abdominal aortic aneurysm undergoing fenestrated stent grafting were selected for inclusion in the study. Conventional 2D views including axial, multiplanar reformation, maximum-intensity projection, and volume rendering and 3D stereoscopic visualizations were assessed by two experienced reviewers independently with regard to the treatment outcomes of fenestrated repair. Interobserver agreement was assessed with Kendall's W statistic. Multiplanar reformation and maximum-intensity projection visualizations were scored the highest in the evaluation of parameters related to the fenestrated stent grafting, while 3D stereoscopic visualization was scored as valuable in the evaluation of appearance (any distortions) of the fenestrated stent. Volume rendering was found to play a limited role in the follow-up of fenestrated stent grafting. 3D stereoscopic visualization adds additional information that assists endovascular specialists to identify any distortions of the fenestrated stents when compared with 2D visualizations.

  7. Self-assembly of graft polyurethanes having both crystallizable poly({epsilon}-caprolactone) blocks and soft poly(n-butyl acrylate) segments

    Energy Technology Data Exchange (ETDEWEB)

    Ibarboure, E.; Baron, A.; Papon, E. [Laboratoire de Chimie des Polymeres Organiques (LCPO), CNRS, Universite Bordeaux I. 16, Avenue Pey Berland, 33607, Pessac-Cedex (France); Rodriguez-Hernandez, J., E-mail: jrodriguez@enscpb.f [Laboratoire de Chimie des Polymeres Organiques (LCPO), CNRS, Universite Bordeaux I. 16, Avenue Pey Berland, 33607, Pessac-Cedex (France)

    2009-04-02

    We report the self-assembly behavior of graft polyurethanes combining in its structure soft lateral poly(n-butyl acrylate) (PnBuA) chains with rigid and crystallizable polycaprolactone (PCL) segments. Segmented polyurethanes microphase separated into high-glass transition temperature PCL hard and low-glass transition temperature PnBuA soft domains. The variation of the microstructure as a function of the hard segment content (ratio hard to soft segments) within the structure has been studied by using atomic force microscopy. Additionally, the crystallization mechanism appeared to be directly related to the properties of the substrates forming parallel lamellar structures on hydrophilic substrates and perpendicular lamellae with hydrophobic substrates.

  8. H-Ransac a Hybrid Point Cloud Segmentation Combining 2d and 3d Data

    Science.gov (United States)

    Adam, A.; Chatzilari, E.; Nikolopoulos, S.; Kompatsiaris, I.

    2018-05-01

    In this paper, we present a novel 3D segmentation approach operating on point clouds generated from overlapping images. The aim of the proposed hybrid approach is to effectively segment co-planar objects, by leveraging the structural information originating from the 3D point cloud and the visual information from the 2D images, without resorting to learning based procedures. More specifically, the proposed hybrid approach, H-RANSAC, is an extension of the well-known RANSAC plane-fitting algorithm, incorporating an additional consistency criterion based on the results of 2D segmentation. Our expectation that the integration of 2D data into 3D segmentation will achieve more accurate results, is validated experimentally in the domain of 3D city models. Results show that HRANSAC can successfully delineate building components like main facades and windows, and provide more accurate segmentation results compared to the typical RANSAC plane-fitting algorithm.

  9. Intercalary bone segment transport in treatment of segmental tibial defects

    International Nuclear Information System (INIS)

    Iqbal, A.; Amin, M.S.

    2002-01-01

    Objective: To evaluate the results and complications of intercalary bone segment transport in the treatment of segmental tibial defects. Design: This is a retrospective analysis of patients with segmental tibial defects who were treated with intercalary bone segment transport method. Place and Duration of Study: The study was carried out at Combined Military Hospital, Rawalpindi from September 1997 to April 2001. Subjects and methods: Thirteen patients were included in the study who had developed tibial defects either due to open fractures with bone loss or subsequent to bone debridement of infected non unions. The mean bone defect was 6.4 cms and there were eight associated soft tissue defects. Locally made unilateral 'Naseer-Awais' (NA) fixator was used for bone segment transport. The distraction was done at the rate of 1mm/day after 7-10 days of osteotomy. The patients were followed-up fortnightly during distraction and monthly thereafter. The mean follow-up duration was 18 months. Results: The mean time in external fixation was 9.4 months. The m ean healing index' was 1.47 months/cm. Satisfactory union was achieved in all cases. Six cases (46.2%) required bone grafting at target site and in one of them grafting was required at the level of regeneration as well. All the wounds healed well with no residual infection. There was no residual leg length discrepancy of more than 20 mm nd one angular deformity of more than 5 degrees. The commonest complication encountered was pin track infection seen in 38% of Shanz Screws applied. Loosening occurred in 6.8% of Shanz screws, requiring re-adjustment. Ankle joint contracture with equinus deformity and peroneal nerve paresis occurred in one case each. The functional results were graded as 'good' in seven, 'fair' in four, and 'poor' in two patients. Overall, thirteen patients had 31 (minor/major) complications with a ratio of 2.38 complications per patient. To treat the bone defects and associated complications, a mean of

  10. Kinetics of vein graft hyperplasia

    International Nuclear Information System (INIS)

    Zwolak, R.M.; Adams, M.C.; Clowes, A.W.

    1986-01-01

    Human aortocoronary vein grafts fail due to accelerated occlusive disease. The possibility that this is related to cellular hyperplasia was investigated in a rabbit model where kinetics of vein graft thickening, endothelial (EC) repair, and smooth muscle cell (SMC) proliferation were measured from 2 days to 24 weeks after implanting jugular vein segments in the carotid artery. Immediately after graft placement focal EC denudation was observed. These defects were repaired within 1 week and did not recur. By 4 weeks intimal area had increased 30 fold from 0.028 +/- 0.004 to 0.705 +/- 0.021 mm 2 , and a 24 weeks was 0.93 +/- 0.21 mm 2 . This response did not produce a reduction in graft lumen area. EC and SMC thymidine-labeling index were measured by en face and cross-section autoradiography after injection of 3 H-thymidine and perfusion fixation. Despite rapid EC surface repair EC labeling index remained elevated and only returned to normal levels at 12 weeks; SMC labeling was 10 fold greater than baseline even at 24 weeks (0.22% vs 0.02%). SMC mass demonstrated morphometrically increased between 2 and 12 weeks. Intimal thickening in vein grafts is due to SMC proliferation and develops after the EC layer has been restored. In contrast, intimal SMC proliferate in damaged arteries when the EC layer is absent and cease when the EC layer is regenerated

  11. 3D segmentation of kidney tumors from freehand 2D ultrasound

    Science.gov (United States)

    Ahmad, Anis; Cool, Derek; Chew, Ben H.; Pautler, Stephen E.; Peters, Terry M.

    2006-03-01

    To completely remove a tumor from a diseased kidney, while minimizing the resection of healthy tissue, the surgeon must be able to accurately determine its location, size and shape. Currently, the surgeon mentally estimates these parameters by examining pre-operative Computed Tomography (CT) images of the patient's anatomy. However, these images do not reflect the state of the abdomen or organ during surgery. Furthermore, these images can be difficult to place in proper clinical context. We propose using Ultrasound (US) to acquire images of the tumor and the surrounding tissues in real-time, then segmenting these US images to present the tumor as a three dimensional (3D) surface. Given the common use of laparoscopic procedures that inhibit the range of motion of the operator, we propose segmenting arbitrarily placed and oriented US slices individually using a tracked US probe. Given the known location and orientation of the US probe, we can assign 3D coordinates to the segmented slices and use them as input to a 3D surface reconstruction algorithm. We have implemented two approaches for 3D segmentation from freehand 2D ultrasound. Each approach was evaluated on a tissue-mimicking phantom of a kidney tumor. The performance of our approach was determined by measuring RMS surface error between the segmentation and the known gold standard and was found to be below 0.8 mm.

  12. Dr. Liver: A preoperative planning system of liver graft volumetry for living donor liver transplantation.

    Science.gov (United States)

    Yang, Xiaopeng; Yang, Jae Do; Yu, Hee Chul; Choi, Younggeun; Yang, Kwangho; Lee, Tae Beom; Hwang, Hong Pil; Ahn, Sungwoo; You, Heecheon

    2018-05-01

    Manual tracing of the right and left liver lobes from computed tomography (CT) images for graft volumetry in preoperative surgery planning of living donor liver transplantation (LDLT) is common at most medical centers. This study aims to develop an automatic system with advanced image processing algorithms and user-friendly interfaces for liver graft volumetry and evaluate its accuracy and efficiency in comparison with a manual tracing method. The proposed system provides a sequential procedure consisting of (1) liver segmentation, (2) blood vessel segmentation, and (3) virtual liver resection for liver graft volumetry. Automatic segmentation algorithms using histogram analysis, hybrid level-set methods, and a customized region growing method were developed. User-friendly interfaces such as sequential and hierarchical user menus, context-sensitive on-screen hotkey menus, and real-time sound and visual feedback were implemented. Blood vessels were excluded from the liver for accurate liver graft volumetry. A large sphere-based interactive method was developed for dividing the liver into left and right lobes with a customized cutting plane. The proposed system was evaluated using 50 CT datasets in terms of graft weight estimation accuracy and task completion time through comparison to the manual tracing method. The accuracy of liver graft weight estimation was assessed by absolute difference (AD) and percentage of AD (%AD) between preoperatively estimated graft weight and intraoperatively measured graft weight. Intra- and inter-observer agreements of liver graft weight estimation were assessed by intraclass correlation coefficients (ICCs) using ten cases randomly selected. The proposed system showed significantly higher accuracy and efficiency in liver graft weight estimation (AD = 21.0 ± 18.4 g; %AD = 3.1% ± 2.8%; percentage of %AD > 10% = none; task completion time = 7.3 ± 1.4 min) than the manual tracing method (AD = 70

  13. Development of a Three-Dimensional (3D) Printed Biodegradable Cage to Convert Morselized Corticocancellous Bone Chips into a Structured Cortical Bone Graft

    Science.gov (United States)

    Chou, Ying-Chao; Lee, Demei; Chang, Tzu-Min; Hsu, Yung-Heng; Yu, Yi-Hsun; Liu, Shih-Jung; Ueng, Steve Wen-Neng

    2016-01-01

    This study aimed to develop a new biodegradable polymeric cage to convert corticocancellous bone chips into a structured strut graft for treating segmental bone defects. A total of 24 adult New Zealand white rabbits underwent a left femoral segmental bone defect creation. Twelve rabbits in group A underwent three-dimensional (3D) printed cage insertion, corticocancellous chips implantation, and Kirschner-wire (K-wire) fixation, while the other 12 rabbits in group B received bone chips implantation and K-wire fixation only. All rabbits received a one-week activity assessment and the initial image study at postoperative 1 week. The final image study was repeated at postoperative 12 or 24 weeks before the rabbit scarification procedure on schedule. After the animals were sacrificed, both femurs of all the rabbits were prepared for leg length ratios and 3-point bending tests. The rabbits in group A showed an increase of activities during the first week postoperatively and decreased anterior cortical disruptions in the postoperative image assessments. Additionally, higher leg length ratios and 3-point bending strengths demonstrated improved final bony ingrowths within the bone defects for rabbits in group A. In conclusion, through this bone graft converting technique, orthopedic surgeons can treat segmental bone defects by using bone chips but with imitate characters of structured cortical bone graft. PMID:27104525

  14. Development of a Three-Dimensional (3D Printed Biodegradable Cage to Convert Morselized Corticocancellous Bone Chips into a Structured Cortical Bone Graft

    Directory of Open Access Journals (Sweden)

    Ying-Chao Chou

    2016-04-01

    Full Text Available This study aimed to develop a new biodegradable polymeric cage to convert corticocancellous bone chips into a structured strut graft for treating segmental bone defects. A total of 24 adult New Zealand white rabbits underwent a left femoral segmental bone defect creation. Twelve rabbits in group A underwent three-dimensional (3D printed cage insertion, corticocancellous chips implantation, and Kirschner-wire (K-wire fixation, while the other 12 rabbits in group B received bone chips implantation and K-wire fixation only. All rabbits received a one-week activity assessment and the initial image study at postoperative 1 week. The final image study was repeated at postoperative 12 or 24 weeks before the rabbit scarification procedure on schedule. After the animals were sacrificed, both femurs of all the rabbits were prepared for leg length ratios and 3-point bending tests. The rabbits in group A showed an increase of activities during the first week postoperatively and decreased anterior cortical disruptions in the postoperative image assessments. Additionally, higher leg length ratios and 3-point bending strengths demonstrated improved final bony ingrowths within the bone defects for rabbits in group A. In conclusion, through this bone graft converting technique, orthopedic surgeons can treat segmental bone defects by using bone chips but with imitate characters of structured cortical bone graft.

  15. Graft copolymers of polypropylene films. 1. radiation induced grafting of mixed monomers. Vol. 3

    International Nuclear Information System (INIS)

    El-Salmawi, K.M.; El-Naggar, A.M.; Said, H.M.; Zahran, A.H.

    1996-01-01

    Radiation graft copolymerization of co monomer mixtures of acrylic acid (AAC), and styrene (S) onto polypropylene (PP) film by mutual method has been investigated. The effects of different factors that may affect the grafting yield such as inhibitor concentration (Mohr's salt), solvent composition (MeOH and H 2 O), radiation dose and dose rate were considered. It was found that the role of Mohr's salt is very effective when the ratio of AAC in the co monomer mixtures was at lower values. However, the addition of 1.25 Wt% of Mohr's salt reduced the homo polymer formation and enhances the grafting process. Graft copolymerization in presence of solvent mixture composed of methanol and water was found to afford higher grafting than in pure methanol regardless of the composition of the co monomer mixture used. However, the highest degree of grafting was obtained at a solvent composition of 20% H 2 O:80%MeOH and a co monomer mixture of 20%AAC:80%sty. An attempt was made to determine each PAAC and PS fractions in the total graft yield obtained. Two methods of analysis based on using the reactivity ratios reported in literature, elemental analysis and IR spectroscopy. The determination of poly (acrylic acid) and polystyrene fractions by elemental analysis is believed more accurate than these by reactivity ratio. The precise results obtained by elemental analysis with respect to the chemical structure of known polymer prepared under identical conditions. The results obtained by IR measurements go well with that obtained with the reactivity ratio methods. 5 figs., 3 tabs

  16. Regiocontroll synthesis cellulose-graft-polycaprolactone copolymer (2,3-di-O-PCL-cellulose by a new route

    Directory of Open Access Journals (Sweden)

    K. L. Wang

    2017-12-01

    Full Text Available A new and convenient route to the regiocontrolled synthesis of a cellulose-based derivate copolymer (2,3-di-O-polycaprolactone-cellulose grafting ε-caprolactone (ε-CL from α-cellulose, cellulose-graft-polycaprolactone (cellulose-g-PCL, by a classical ring-opening polymerization (ROP reaction, using stannous octoate (Sn(Oct2 as catalyst, in 68% concentration of zinc chloride aqueous solution at 120 °C was presented. By controlling the hydroxyl of cellulose/ε-CL, catalyst/monomer ratio and the reaction time, the molecular architecture of the copolymers can be altered. The solubility of cellulose in zinc chloride aqueous was indicated by UV/VIS spectrometer and rheological measurements. The structures and thermal properties of cellulose-g-polycaprolactone copolymers were characterized using Fourier Transform Infrared (FT-IR, Proton Nuclear Magnetic Resonance Spectroscopy (1H NMR, X-ray Diffraction (XRD, Thermogravimetric Analysis (TGA, Differential Scanning Calorimetry (DSC and Inductively Coupled Plasma Optical Emission Spectrometry (ICP-OES. The interesting results confirm that zinc chloride solution can break the intra-molecular hydrogen bonds of cellulose selectively (not only O3H···O5, but also O2H···O6, and has no effect on the inter-molecular hydrogen bonds (O6H···O3. And the grafting reactivity of hydroxyl on cellulose is C2–OH > C3–OH >> C6–OH in zinc chloride solution, and this is clearly different from other researches. Most importantly, this work confirms that the method to regiocontrolled synthesis cellulose-based derivative polymers by regiobreaking hydrogen bonds is feasible. It is strongly believed that the new discovery may give a novel, environmental, simple and inexpensive method to modify cellulose chemically with various side chains grafted on a given hydroxyl, through liberating hydroxyl as reactive group from hydrogen bonds broken selectively by different solvents.

  17. Graft copolymers of polypropylene films. 1. radiation induced grafting of mixed monomers. Vol. 3

    Energy Technology Data Exchange (ETDEWEB)

    El-Salmawi, K M; El-Naggar, A M; Said, H M; Zahran, A H [Radiation Chemistry Department, National Center for Radiation Research and Technology, Atomic Energy Authority, Cairo, (Egypt)

    1996-03-01

    Radiation graft copolymerization of co monomer mixtures of acrylic acid (AAC), and styrene (S) onto polypropylene (PP) film by mutual method has been investigated. The effects of different factors that may affect the grafting yield such as inhibitor concentration (Mohr`s salt), solvent composition (MeOH and H{sub 2} O), radiation dose and dose rate were considered. It was found that the role of Mohr`s salt is very effective when the ratio of AAC in the co monomer mixtures was at lower values. However, the addition of 1.25 Wt% of Mohr`s salt reduced the homo polymer formation and enhances the grafting process. Graft copolymerization in presence of solvent mixture composed of methanol and water was found to afford higher grafting than in pure methanol regardless of the composition of the co monomer mixture used. However, the highest degree of grafting was obtained at a solvent composition of 20% H{sub 2} O:80%MeOH and a co monomer mixture of 20%AAC:80%sty. An attempt was made to determine each PAAC and PS fractions in the total graft yield obtained. Two methods of analysis based on using the reactivity ratios reported in literature, elemental analysis and IR spectroscopy. The determination of poly (acrylic acid) and polystyrene fractions by elemental analysis is believed more accurate than these by reactivity ratio. The precise results obtained by elemental analysis with respect to the chemical structure of known polymer prepared under identical conditions. The results obtained by IR measurements go well with that obtained with the reactivity ratio methods. 5 figs., 3 tabs.

  18. Revascularization of diaphyseal bone segments by vascular bundle implantation.

    Science.gov (United States)

    Nagi, O N

    2005-11-01

    Vascularized bone transfer is an effective, established treatment for avascular necrosis and atrophic or infected nonunions. However, limited donor sites and technical difficulty limit its application. Vascular bundle transplantation may provide an alternative. However, even if vascular ingrowth is presumed to occur in such situations, its extent in aiding revascularization for ultimate graft incorporation is not well understood. A rabbit tibia model was used to study and compare vascularized, segmental, diaphyseal, nonvascularized conventional, and vascular bundle-implanted grafts with a combination of angiographic, radiographic, histopathologic, and bone scanning techniques. Complete graft incorporation in conventional grafts was observed at 6 months, whereas it was 8 to 12 weeks with either of the vascularized grafts. The pattern of radionuclide uptake and the duration of graft incorporation between vascular segmental bone grafts (with intact endosteal blood supply) and vascular bundle-implanted segmental grafts were similar. A vascular bundle implanted in the recipient bone was found to anastomose extensively with the intraosseous circulation at 6 weeks. Effective revascularization of bone could be seen when a simple vascular bundle was introduced into a segment of bone deprived of its normal blood supply. This simple technique offers promise for improvement of bone graft survival in clinical circumstances.

  19. Long-term results of 2-mm punch grafting in patients with vitiligo vulgaris and segmental vitiligo: effect of disease activity

    NARCIS (Netherlands)

    Fongers, A.; Wolkerstorfer, A.; Nieuweboer-Krobotova, L.; Krawczyk, P.; Tóth, G. G.; van der Veen, J. P. W.

    2009-01-01

    Background Punch grafting is a simple and frequently used technique for the treatment of stable vitiligo, resistant to medical therapy. However, studies reporting long-term results are exceptional. Objectives To evaluate the long-term results of 2-mm punch grafting in patients with vitiligo vulgaris

  20. Long-term results of 2-mm punch grafting in patients with vitiligo vulgaris and segmental vitiligo : effect of disease activity

    NARCIS (Netherlands)

    Fongers, A.; Wolkerstorfer, A.; Nieuweboer-Krobotova, L.; Krawczyk, P.; Toth, G. G.; van der Veen, J. P. W.

    Background Punch grafting is a simple and frequently used technique for the treatment of stable vitiligo, resistant to medical therapy. However, studies reporting long-term results are exceptional. Objectives To evaluate the long-term results of 2-mm punch grafting in patients with vitiligo vulgaris

  1. Long-term results of 2-mm punch grafting in patients with vitiligo vulgaris and segmental vitiligo : effect of disease activity

    NARCIS (Netherlands)

    Fongers, A.; Wolkerstorfer, A.; Nieuweboer-Krobotova, L.; Krawczyk, P.; Toth, G. G.; van der Veen, J. P. W.

    2009-01-01

    Background Punch grafting is a simple and frequently used technique for the treatment of stable vitiligo, resistant to medical therapy. However, studies reporting long-term results are exceptional. Objectives To evaluate the long-term results of 2-mm punch grafting in patients with vitiligo vulgaris

  2. Diabetes patients show different time-course of myocardial perfusion improvement after coronary artery bypass grafting

    International Nuclear Information System (INIS)

    Lee, J. J.; Seok, J. W.; Eo, J. S.

    2005-01-01

    Diabetes mellitus is an independent risk factor of cardiovascular disease. Diabetes is known to cause microangiopathy. The microangiopathy is hardly detectable on the coronary angiography. Myocardial perfusion imaging shows the resultant perfusion status which reflects the microangiopathy. For patients who underwent revascularization, the microangiopathy could affect the myocardial perfusion improvement. Diabetes patients probably experience the different myocardial perfusion improvement as compared to the non-diabetes patients although they have similar angiographic findings. The aim of this study is to find out whether there is a time-course difference of perfusion improvement between the diabetes and non diabetes patients who showed patent angiographic findings after coronary artery grafting surgery (CABG). A total of 129 patients who underwent coronary artery bypass grafting surgery were enrolled in this study. Myocardial SPECTs performed at previous, short-term (3 month), and mid-term (1 year) to CABG. One-year follow up angiography was done 411±121 days after surgery. Graft patency was determined according to the FitzGibbon et al. Segments were assigned to vascular territories using a 20 segment model. The segments of excellent patency were included in this study. Time course differences of concerned segments were analyzed using RMANOVA. The number of segments enrolled was 764 of diabetes and 1083 of non-diabetes. At short-term follow up, reversibility score was 2.8±8.1% in diabetes and 0.3±7.5% in non-diabetes. At long-term follow up, reversibility score was 1.8±8.0% in diabetes and 0.1±7.3% in non-diabetes. The time-course of reversibility score was significantly different between the diabetes and non diabetes (p<0.001) Diabetic segments showed high residual reversibility score than non-diabetic segments after CABG although the angiographic finding was patent in both groups. This result is maybe attributable to microangiopathy induced by diabetes

  3. C1-esterase inhibitor protects against early vein graft remodeling under arterial blood pressure.

    Science.gov (United States)

    Krijnen, Paul A J; Kupreishvili, Koba; de Vries, Margreet R; Schepers, Abbey; Stooker, Wim; Vonk, Alexander B A; Eijsman, Leon; Van Hinsbergh, Victor W M; Zeerleder, Sacha; Wouters, Diana; van Ham, Marieke; Quax, Paul H A; Niessen, Hans W M

    2012-01-01

    Arterial pressure induced vein graft injury can result in endothelial loss, accelerated atherosclerosis and vein graft failure. Inflammation, including complement activation, is assumed to play a pivotal role herein. Here, we analyzed the effects of C1-esterase inhibitor (C1inh) on early vein graft remodeling. Human saphenous vein graft segments (n=8) were perfused in vitro with autologous blood either supplemented or not with purified human C1inh at arterial pressure for 6h. The vein segments and perfusion blood were analyzed for cell damage and complement activation. In addition, the effect of purified C1inh on vein graft remodeling was analyzed in vivo in atherosclerotic C57Bl6/ApoE3 Leiden mice, wherein donor caval veins were interpositioned in the common carotid artery. Application of C1inh in the in vitro perfusion model resulted in significantly higher blood levels and significantly more depositions of C1inh in the vein wall. This coincided with a significant reduction in endothelial loss and deposition of C3d and C4d in the vein wall, especially in the circular layer, compared to vein segments perfused without supplemented C1inh. Administration of purified C1inh significantly inhibited vein graft intimal thickening in vivo in atherosclerotic C57Bl6/ApoE3 Leiden mice, wherein donor caval veins were interpositioned in the common carotid artery. C1inh significantly protects against early vein graft remodeling, including loss of endothelium and intimal thickening. These data suggest that it may be worth considering its use in patients undergoing coronary artery bypass grafting. Copyright © 2011 Elsevier Ireland Ltd. All rights reserved.

  4. MR Imaging of Stable Posterior Cruciate Ligament Grafts in 21 Arthroscopically Proven Cases

    International Nuclear Information System (INIS)

    Yoon, Young Cheol; Chung, Hye Won; Ahn, Jin Hwan

    2007-01-01

    To describe the magnetic resonance (MR) appearance of intact posterior cruciate ligament (PCL) grafts. Thirty-one postoperative MR examinations were performed in 21 grafts of 20 patients after PCL reconstruction. All 21 grafts were proven to be intact on second-look arthroscopic examination. Two musculoskeletal radiologists retrospectively analyzed the MR findings and reached decisions by consensus. The signal intensity (SI) of the graft on proton density-weighted and T2-weighted images, as well as the shapes, locations, and segments of increased SI were recorded. The graft thickness was also recorded and correlated to elapsed time since reconstructive surgery. The SI of the graft was high (15/31, 48%), intermediate (10/31, 32%), or low (6/31, 19%) on proton density-weighted images, and high (9/31, 29%), intermediate (6/31, 19%), or low (16/31, 52%) on T2-weighted images. The graft SI decreased significantly as postoperative time elapsed. The shape of the increased SI within the grafts was band-like (14/25, 56%) or focal (11/25, 44%). The increased SI was located in the proximal (18/25, 72%), middle (21/25, 82%), and distal (12/25, 48%) segments. In the axial plane, the location of increased SI was intrasubstance (19/25, 76%) or peripheral (10/25, 40%). A 'focal' shape of increased SI was found significantly more in Achilles tendon allografts, while a band-like shape was more frequent in autogenous double-loop hamstring tendon grafts. Graft thickness ranged from 5 15 mm. The difference in graft thickness relative to postoperative time was not statistically significant (p = 0.79). Stable PCL grafts commonly showed an increased SI at any segment or location, even though they were stable. The shape of increased SI differed according to allograft donor sites. However, SI tended to decrease as time elapsed

  5. Primary nerve grafting: A study of revascularization.

    Science.gov (United States)

    Chalfoun, Charbel; Scholz, Thomas; Cole, Matthew D; Steward, Earl; Vanderkam, Victoria; Evans, Gregory R D

    2003-01-01

    It was the purpose of this study to evaluate the revascularization of primary nerve repair and grafts using orthogonal polarization spectral (OPS) (Cytometrix, Inc.) imaging, a novel method for real-time evaluation of microcirculatory blood flow. Twenty male Sprague Dawley rats (250 g) were anesthetized with vaporized halothane and surgically prepared for common peroneal nerve resection. Group I animals (n = 10) underwent primary neurorraphy following transection, utilizing a microsurgical technique with 10-0 nylon suture. Group II (n = 10) animals had a 7-mm segment of nerve excised, reversed, and subsequently replaced as a nerve graft under similar techniques. All animals were evaluated using the OPS imaging system on three portions (proximal, transection site/graft, and distal) of the nerve following repair or grafting. Reevaluation of 5 animals randomly selected from each group using the OPS imaging system was again performed on days 14 and 28 following microsurgical repair/grafting. Values were determined by percent change in vascularity of the common peroneal nerve at 0 hr following surgery. Real-time evaluation of blood flow was utilized as an additional objective criterion. Percent vascularity in group I and II animals increased from baseline in all segments at day 14. By day 28, vascularity in nerves of group I rats decreased in all segments to values below baseline, with the exception of the transection site, which remained at a higher value than obtained directly after surgical repair. In group II animals, vascularity remained above baseline in all segments except the distal segment, which returned to vascularity levels similar to those at 0 hr. Further, occlusion of the vessels demonstrated in the graft and distal segments following initial transection appeared to be corrected. This study suggests that revascularization may occur via bidirectional inosculation with favored proximal vascular growth advancement. The use of real-time imaging offers a

  6. Stent graft placement for dysfunctional arteriovenous grafts

    Energy Technology Data Exchange (ETDEWEB)

    Jeon, Gyeong Sik [Dept. of Radiology, CHA Bundang Medical Center, College of Medicine, CHA University, Seongnam (Korea, Republic of); Shin, Byung Seok; Ohm, Joon Young; Ahn, Moon Sang [Chungnam National University Hospital, Daejeon (Korea, Republic of)

    2015-07-15

    This study aimed to evaluate the usefulness and outcomes of stent graft use in dysfunctional arteriovenous grafts. Eleven patients who underwent stent graft placement for a dysfunctional hemodialysis graft were included in this retrospective study. Expanded polytetrafluoroethylene covered stent grafts were placed at the venous anastomosis site in case of pseudoaneurysm, venous laceration, elastic recoil or residual restenosis despite the repeated angioplasty. The patency of the arteriovenous graft was evaluated using Kaplan-Meier analysis. Primary and secondary mean patency was 363 days and 741 days. Primary patency at 3, 6, and 12 months was 82%, 73%, and 32%, respectively. Secondary patency at the 3, 6, 12, 24, and 36 months was improved to 91%, 82%, 82%, 50%, and 25%, respectively. Fractures of the stent graft were observed in 2 patients, but had no effect on the patency. Stent graft placement in dysfunctional arteriovenous graft is useful and effective in prolonging graft patency.

  7. Development of a 3D bellows tracheal graft: mechanical behavior analysis, fabrication and an in vivo feasibility study

    International Nuclear Information System (INIS)

    Park, Jeong Hun; Jung, Jin Woo; Lee, Jung-Seob; Cho, Dong-Woo; Kang, Hyun-Wook; Joo, Young Hoon

    2012-01-01

    Artificial tracheal grafts should have not only enough compressive strength to maintain an open tracheal lumen, but also sufficient flexibility for stable mechanical behavior, similar to the native trachea at the implant site. In this study, we developed a new 3D artificial tracheal graft using a bellows design for considering its mechanical behavior. To investigate the mechanical behavior of the bellows structure, finite element method (FEM) analysis in terms of longitudinal tension/compression, bending and radial compression was conducted. The bellows structure was then compared with the cylinder structure generally used for artificial tracheal grafts. The FEM analysis showed that the bellows had outstanding flexibility in longitudinal tension/compression and bending. Moreover, the bellows kept the lumen open without severe luminal deformation in comparison with the cylinder structure. A three-dimensional artificial tracheal graft with a bellows design was fabricated using indirect solid freeform fabrication technology, and the actual mechanical test was conducted to investigate the actual mechanical behavior of the bellows graft. The fabricated bellows graft was then applied to segmental tracheal reconstruction in a rabbit model to assess its applicability. The bellows graft was completely incorporated into newly regenerated connective tissue and no obstruction at the implanted site was observed for up to 8 weeks after implantation. The data suggested that the developed bellows tracheal graft could be a promising alternative for tracheal reconstruction. (paper)

  8. Tubal Buccal Mucosa Graft without Anastomosis of the Proximal Urethra for Long Segment Posterior Urethral Defect Repair.

    Science.gov (United States)

    Min, Byung-Dal; Lee, Eui-Tai; Kim, Won-Tae; Kim, Yong-June; Yun, Seok Joong; Lee, Sang Cheol; Kim, Wun-Jae

    2012-10-01

    A 31-year-old man was referred for further management of a urethral stricture. He was a victim of a traffic accident and his urethral injury was associated with a pelvic bone fracture. He had previously undergone a suprapubic cystostomy only owing to his unstable general condition at another hospital. After 3 months of urethral injury, direct urethral anastomosis was attempted, but the surgery failed. An additional 4 failed internal urethrotomies were performed before the patient visited Chungbuk National University Hospital. Preoperative images revealed complete posterior urethral disruption, and the defect length was 4 cm. We performed a buccal mucosa tubal graft without anastomosis of the proximal urethra for a long segment posterior urethral defect. The Foley catheter was removed 3 weeks after the operation and the patient was able to void successfully. After 8 months, he had normal voiding function without urinary incontinence.

  9. Special distraction osteogenesis before bone grafting for alveolar cleft defects to correct maxillary deformities in patients with bilateral cleft lips and palates: distraction osteogenesis performed separately for each bone segment.

    Science.gov (United States)

    Mitsukawa, Nobuyuki; Saiga, Atsuomi; Morishita, Tadashi; Satoh, Kaneshige

    2014-07-01

    Patients with bilateral cleft lips and palates have premaxillary protrusion and characteristic jaw deformities involving three-dimensional malposition of the premaxilla and bilateral maxillary bone segments. This study examined patients with bilateral cleft lips and palates who had deviation and hypoplasia of the premaxillas and bilateral maxillary segments. Before bone grafting, the patients were treated with special distraction performed separately for each bone segment using a halo-type external device. This report describes this novel treatment method which produced good results. The subjects were five patients with severe jaw deformities due to bilateral cleft lip and palate. They were treated with maxillary Le Fort I osteotomy and subsequent distraction performed separately for each bone segment using a halo device. In three of five patients, premaxillary osteotomy was not performed, and osteotomy and distraction were performed only for the right and left lateral segments with severe hypoplasia. All patients achieved distraction close to the desired amount. The widths of the alveolar clefts were narrowed, and satisfactory occlusion and maxillary arch form were achieved. After the surgery, three of five patients underwent bone grafting for bilateral alveolar cleft defects and the bone graft survival was satisfactory. This method had many benefits, including narrowing of alveolar clefts, improvement of maxillary hypoplasia, and achievement of a good maxillary arch form. In addition, subsequent bone grafting for alveolar cleft defects was beneficial, dental prostheses were unnecessary, and frequency of surgery and surgical invasiveness were reduced. This method is a good surgical procedure that should be considered for patients with bilateral cleft lips and palates who have premaxillary protrusion and hypoplasia of the right and left lateral segments. Copyright © 2013 European Association for Cranio-Maxillo-Facial Surgery. Published by Elsevier Ltd. All rights

  10. Efficient visible light photocatalytic NO{sub x} removal with cationic Ag clusters-grafted (BiO){sub 2}CO{sub 3} hierarchical superstructures

    Energy Technology Data Exchange (ETDEWEB)

    Feng, Xin [Chongqing Key Laboratory of Catalysis and Functional Organic Molecules, College of Environment and Resources, Engineering Research Center for Waste Oil Recovery Technology and Equipment of Ministry of Education, College of Environment and Resources, Chongqing Technology and Business University, Chongqing 40067 (China); Zhang, Wendong [Department of Scientific Research Management, Chongqing Normal University, Chongqing 401331 (China); Deng, Hua [State Key Joint Laboratory of Environment Simulation and Pollution Control, Research Center for Eco-Environmental Sciences, Chinese Academy of Sciences, Beijing 100085 (China); Ni, Zilin [Department of Scientific Research Management, Chongqing Normal University, Chongqing 401331 (China); Dong, Fan, E-mail: dfctbu@126.com [Chongqing Key Laboratory of Catalysis and Functional Organic Molecules, College of Environment and Resources, Engineering Research Center for Waste Oil Recovery Technology and Equipment of Ministry of Education, College of Environment and Resources, Chongqing Technology and Business University, Chongqing 40067 (China); Zhang, Yuxin, E-mail: zhangyuxin@cqu.edu.cn [College of Materials Science and Engineering, National Key Laboratory of Fundamental Science of Micro/Nano-Devices and System Technology, Chongqing University, Chongqing 400044 (China)

    2017-01-15

    Graphical abstract: The cationic Ag clusters-grafted (BiO){sub 2}CO{sub 3} hierarchical superstructures exhibits highly enhanced visible light photocatalytic air purification through an interfacial charge transfer process induced by Ag clusters. - Highlights: • Microstructural optimization and surface cluster-grafting were firstly combined. • Cationic Ag clusters were grafted on the surface of (BiO){sub 2}CO{sub 3} superstructures. • The Ag clusters-grafted BHS displayed enhanced visible light photocatalysis. • Direct interfacial charge transfer (IFCT) from BHS to Ag clusters was proposed. • The charge transfer process and the dominant reactive species were revealed. - Abstract: A facile method was developed to graft cationic Ag clusters on (BiO){sub 2}CO{sub 3} hierarchical superstructures (BHS) surface to improve their visible light activity. Significantly, the resultant Ag clusters-grafted BHS displayed a highly enhanced visible light photocatalytic performance for NOx removal due to the direct interfacial charge transfer (IFCT) from BHS to Ag clusters. The chemical and coordination state of the cationic Ag clusters was determined with the extended X-ray absorption fine structure (EXAFS) and a theoretical structure model was proposed for this unique Ag clusters. The charge transfer process and the dominant reactive species (·OH) were revealed on the basis of electron spin resonance (ESR) trapping. A new photocatalysis mechanism of Ag clusters-grafted BHS under visible light involving IFCT process was uncovered. In addition, the cationic Ag clusters-grafted BHS also demonstrated high photochemical and structural stability under repeated photocatalysis runs. The perspective of enhancing photocatalysis through combination of microstructural optimization and IFCT could provide a new avenue for the developing efficient visible light photocatalysts.

  11. Biodegradability of poly(3-hydroxybutyrate) film grafted with vinyl acetate: Effect of grafting and saponification

    Science.gov (United States)

    Wada, Yuki; Seko, Noriaki; Nagasawa, Naotsugu; Tamada, Masao; Kasuya, Ken-ichi; Mitomo, Hiroshi

    2007-06-01

    Radiation-induced graft polymerization of vinyl acetate (VAc) onto poly(3-hydroxybutyrate) (PHB) film was carried out. At a degree of grafting higher than 5%, the grafted films (PHB-g-VAc) completely lost the enzymatic degradability that is characteristic of PHB due to the grafted VAc covering the surface of the PHB film. However, the biodegradability of the PHB-g-VAc films was recovered when the films were saponified in alkali solution under optimum conditions. Graft chains of the PHB-g-VAc film reacted selectively to become biodegradable polyvinyl alcohol (PVA). The biodegradability of the saponified PHB-g-VAc film increased rapidly with time.

  12. Biodegradability of poly(3-hydroxybutyrate) film grafted with vinyl acetate: Effect of grafting and saponification

    International Nuclear Information System (INIS)

    Wada, Yuki; Seko, Noriaki; Nagasawa, Naotsugu; Tamada, Masao; Kasuya, Ken-ichi; Mitomo, Hiroshi

    2007-01-01

    Radiation-induced graft polymerization of vinyl acetate (VAc) onto poly(3-hydroxybutyrate) (PHB) film was carried out. At a degree of grafting higher than 5%, the grafted films (PHB-g-VAc) completely lost the enzymatic degradability that is characteristic of PHB due to the grafted VAc covering the surface of the PHB film. However, the biodegradability of the PHB-g-VAc films was recovered when the films were saponified in alkali solution under optimum conditions. Graft chains of the PHB-g-VAc film reacted selectively to become biodegradable polyvinyl alcohol (PVA). The biodegradability of the saponified PHB-g-VAc film increased rapidly with time

  13. Evaluation of Optimal Pore Size of (3-Aminopropyltriethoxysilane Grafted MCM-41 for Improved CO2 Adsorption

    Directory of Open Access Journals (Sweden)

    Zhilin Liu

    2015-01-01

    Full Text Available An array of new MCM-41 with substantially larger average pore diameters was synthesized through adding 1,3,5-trimethylbenzene (TMB as the swelling agent to explore the effect of pore size on final adsorbent properties. The pore expanded MCM-41 was also grafted with (3-Aminopropyltriethoxysilane (APTES to determine the optimal pore size for CO2 adsorption. The pore-expanded mesoporous MCM-41s showed relatively less structural regularity but significant increments of pore diameter (4.64 to 7.50 nm; the fraction of mesopore volume also illustrated an increase. The adsorption heat values were correlated with the order of the adsorption capacities for pore expanded MCM-41s. After amine functionalization, the adsorption capacities and heat values showed a significant increase. APTES-grafted pore-expanded MCM-41s depicted a high potential for CO2 capture regardless of the major drawback of the high energy required for regeneration.

  14. VO x /SiO 2 Catalyst Prepared by Grafting VOCl 3 on Silica for Oxidative Dehydrogenation of Propane

    KAUST Repository

    Zhu, Haibo; Ould-Chikh, Samy; Dong, Hailin; Llorens, Isabelle; Saih, Youssef; Anjum, Dalaver H.; Hazemann, Jean Louis; Basset, Jean-Marie

    2015-01-01

    The VOx/SiO2 catalysts for oxidative dehydrogenation of propane were synthesized by a simple grafting method. The VOCl3 was first grafted at the surface of SiO2, which was dehydrated at different temperature (from 200 to 1000°C). The formed grafted complexes were then calcined in air, leading to the formation of VOx/SiO2 catalysts. The synthesized catalysts were characterized by nitrogen adsorption, SEM, Raman spectroscopy, temperature-programmed reduction, and extended X-ray absorption fine structure analysis. The SiO2 pretreatment temperature has an evident effect on the loading and dispersion of VOx on SiO2, which finally affects their catalytic performance. High SiO2 treatment temperature is beneficial to dispersing the vanadium oxide species at the SiO2 surface. These materials are efficient catalysts for the catalytic oxidative dehydrogenation of propane to propylene. The best selectivity to propylene is achieved on the VOx/SiO2-(1000) catalyst. The high selectivity and activity are well maintained for three days catalytic reaction. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  15. VO x /SiO 2 Catalyst Prepared by Grafting VOCl 3 on Silica for Oxidative Dehydrogenation of Propane

    KAUST Repository

    Zhu, Haibo

    2015-09-07

    The VOx/SiO2 catalysts for oxidative dehydrogenation of propane were synthesized by a simple grafting method. The VOCl3 was first grafted at the surface of SiO2, which was dehydrated at different temperature (from 200 to 1000°C). The formed grafted complexes were then calcined in air, leading to the formation of VOx/SiO2 catalysts. The synthesized catalysts were characterized by nitrogen adsorption, SEM, Raman spectroscopy, temperature-programmed reduction, and extended X-ray absorption fine structure analysis. The SiO2 pretreatment temperature has an evident effect on the loading and dispersion of VOx on SiO2, which finally affects their catalytic performance. High SiO2 treatment temperature is beneficial to dispersing the vanadium oxide species at the SiO2 surface. These materials are efficient catalysts for the catalytic oxidative dehydrogenation of propane to propylene. The best selectivity to propylene is achieved on the VOx/SiO2-(1000) catalyst. The high selectivity and activity are well maintained for three days catalytic reaction. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  16. 3D-CT evaluation of secondary alveolar bone grafts in alveolar clefts

    Energy Technology Data Exchange (ETDEWEB)

    Naitoh, Hiroshi; Nishimura, Yoshihiko [Kyoto Univ. (Japan). Graduate School of Medicine; Yamawaki, Yoshiroh [Kyoto Katsura Hospital (Japan); Morimoto, Naoki [Kobe City General Hospital (Japan)

    2002-07-01

    From 1994 to 2000, we treated 116 patients with cleft alveolus by secondary alveolar bone grafts, and 48 of them were evaluated morphologically with 3D-CT. The frequency of successful bony bridging was significantly higher in the group whose grafts were completely enveloped (including the anterior alveolar ridge) with a mucoperiosteal flap. The frequency was also significantly higher in the group who underwent bone grafts at the age of 13 or less, and canine eruptions did not influence the ratio. Some cases showed such an improved growth pattern of grafted bone that the shape of the affected maxilla resembled that of the normal side, after long-term follow-up observations. The growth increment was remarkable in anterior maxillary height. Orthodontic management guides the canine or incisor into the reconstructed area of the previous cleft. We surmise that the new occlusal position puts pressure on the grafted bone and promotes further osteogenesis. These findings show that it is important to produce sufficient bony bridge to guide the canine or incisor, not the volume of grafted bone, in secondary alveolar bone grafts. Long-term follow-up observation, after more than 2-3 years, is also necessary to evaluate secondary alveolar bone grafts. (author)

  17. Chronicity of Anterior Cruciate Ligament Deficiency, Part 2: Radiographic Predictors of Early Graft Failure.

    Science.gov (United States)

    Tanaka, Yoshinari; Kita, Keisuke; Takao, Rikio; Amano, Hiroshi; Uchida, Ryohei; Shiozaki, Yoshiki; Yonetani, Yasukazu; Kinugasa, Kazutaka; Mae, Tatsuo; Horibe, Shuji

    2018-02-01

    Accumulating evidence suggests that long-term anterior cruciate ligament (ACL) deficiency can give rise to an abnormal tibiofemoral relationship and subsequent intra-articular lesions. However, the effects of chronic ACL deficiency (ACLD) on early graft failure after anatomic reconstruction remain unclear. We hypothesized that patients with long-term ACLD lasting more than 5 years would have a greater rate of early graft failure due to insufficient intraoperative reduction of the tibia and that the preoperative and immediately postoperative abnormal tibiofemoral relationship in the sagittal plane, such as anterior tibial subluxation (ATS), would correlate with the graft status on postoperative magnetic resonance imaging (MRI). Cohort study; Level of evidence, 3. A total of 358 patients who had undergone anatomic ACL reconstruction with hamstring grafts were divided into 5 groups based on chronicity of ACLD: (1) 0 to 6 months, (2) 6 months to 1 year, (3) 1 to 2 years, (4) 2 to 5 years, and (5) longer than 5 years. Preoperatively and immediately postoperatively, lateral radiographs in full extension were taken in all patients to evaluate the tibiofemoral relationship, specifically with regard to ATS, space for the ACL (sACL), and extension angle. All patients underwent MRI at 6 months to reveal graft status. Groups with a high rate of graft failure were further analyzed to compare demographic and radiographic factors between the intact and failure subgroups, followed by multivariate logistic regression analysis to identify predisposing factors. Graft failure without trauma was observed in 4 (1.8%), 0 (0%), 1 (3.7%), 3 (9.7%), and 8 patients (17.7%) in groups 1, 2, 3, 4, and 5, respectively. Of the 76 patients in groups 4 and 5, significant differences were noted between the failure and intact subgroups in preoperative ATS (4.9 vs 2.4 mm, respectively; P failure (odds ratio, 3.2; 95% CI, 1.37-7.46). Early graft failure at 6 months increased in patients with ACLD

  18. Ionic membranes obtained by radiation-induced graft copolymerization, I-preparation. Vol. 3

    Energy Technology Data Exchange (ETDEWEB)

    Abd El-Rehim, H A; Hegazy, E A [National Center for Radiation and Technology, Atomic Energy Authority, Cairo, (Egypt); Ali, A M.I.; Nowier, H G; Aly, H F [Hot Laboratories Center, atomic Energy Authority, Cairo, (Egypt)

    1996-03-01

    A study has been made on the preparation of ionic membranes by radiation-induced graft copolymerization of acrylic acid (AAC) onto low density polyethylene (LDPE) films. The Suitable conditions at which the grafting proceeds homogeneously were determined. To minimize the homo polymerization of AAC during irradiation process different types of inhibitors were investigated to find that the addition of Fe Cl{sub 3} (1.5 Wt%) effectively reduced such process when compared with other inhibitors used. The suitable diluent for this grafting system is found to be distilled water, methanol and methanol water mixture. The effect of diluent mixture composition, irradiation time, addition of mineral or organic acid and metal chlorides on the grafting yield and its homogeneity in the graft copolymer was determined. It was observed that the grafting yield increased as the content of water increased in MeOH/H{sub 2} O mixture. The addition of oxalic acid to the reaction medium enhanced the grafting process, however, the addition of HCl or H{sub 2} S O{sub 4} resulted in a more homogeneous grafting. The same effect was also observed when metal salts; namely N H{sub 4} Cl, NaCl and Cu Cl{sub 2} were added and resulted in homogeneous grafted membranes. The swelling and permeability of the grafted films prepared were also investigated. Results obtained in this study showed a great promise for the possible practical use of such prepared graft copolymers as a good hydrophilic membrane. The possibility of its use as an ion-exchange membrane for metal waste will be considered.4 figs., 5 tabs.

  19. [Successful correction with stent-graft of coronary artery rupture after angioplasty].

    Science.gov (United States)

    Demin, V V

    2003-01-01

    Rupture and perforation of coronary arteries complicate in average 0.5% of radiosurgical coronary interventions and often are accompanied by serious consequences and high mortality. According to-type of coronary perforation different methods of correction are used, ranging from conservative measures to urgent cardiosurgical interventions. Coronary stent-grafts with 'sandwich' type of construction ore composed from two metal stents and PTFE layer between them. Development of such stents enabled effective radioguided endovascular repair of coronary ruptures. The paper presents the first Russian experience of stout-graft implantation for coronary artery rupture occurred during direct stenting of proximal anterior descending artery and balloon angioplasty in distal segment. The rupture occurred probably because of wall fragility between affected segment and muscular bridge. Stent-graft JoStent 16 mm in length connected with 3-mm balloon was implanted with subsequent complete restitution of blood flow, resolution of pain syndrome and ECG normalization. Echocardiography in operative theatre and one day after surgery showed no intrapericardial fluid. Stent-graft devices for urgent implantation in cases of coronary rupture must be included into obligatory equipment of radiosurgical facilities.

  20. Optimal temporal windows and dose-reducing strategy for coronary artery bypass graft imaging with 256-slice CT

    Energy Technology Data Exchange (ETDEWEB)

    Lu, Kun-Mu [Department of Radiology, Shin Kong Wu Ho-Su Memorial Hospital, 95 Wen Chang Road, Shih Lin District, Taipei 111, Taiwan. (China); Lee, Yi-Wei [Department of Radiology, Kaohsiung Chang Gung Memorial Hospital and Chang Gung University College of Medicine, Kaohsiung, Taiwan (China); Department of Biomedical Imaging and Radiological Sciences, National Yang Ming University, Taipei, Taiwan (China); Guan, Yu-Xiang [Department of Biomedical Imaging and Radiological Sciences, National Yang Ming University, Taipei, Taiwan (China); Chen, Liang-Kuang [Department of Radiology, Shin Kong Wu Ho-Su Memorial Hospital, 95 Wen Chang Road, Shih Lin District, Taipei 111, Taiwan. (China); School of Medicine, Fu Jen Catholic University, Taipei, Taiwan (China); Law, Wei-Yip, E-mail: m002325@ms.skh.org.tw [Department of Radiology, Shin Kong Wu Ho-Su Memorial Hospital, 95 Wen Chang Road, Shih Lin District, Taipei 111, Taiwan. (China); Su, Chen-Tau, E-mail: m005531@ms.skh.org.tw [Department of Radiology, Shin Kong Wu Ho-Su Memorial Hospital, 95 Wen Chang Road, Shih Lin District, Taipei 111, Taiwan. (China); School of Medicine, Fu Jen Catholic University, Taipei, Taiwan (China)

    2013-12-11

    Objective: To determine the optimal image reconstruction windows in the assessment of coronary artery bypass grafts (CABGs) with 256-slice computed tomography (CT), and to assess their associated optimal pulsing windows for electrocardiogram-triggered tube current modulation (ETCM). Methods: We recruited 18 patients (three female; mean age 68.9 years) having mean heart rate (HR) of 66.3 beats per minute (bpm) and a heart rate variability of 1.3 bpm for this study. A total of 36 CABGs with 168 segments were evaluated, including 12 internal mammary artery (33.3%) and 24 saphenous vein grafts (66.7%). We reconstructed 20 data sets in 5%-step through 0–95% of the R–R interval. The image quality of CABGs was assessed by a 5-point scale (1=excellent to 5=non-diagnostic) for each segment (proximal anastomosis, proximal, middle, distal course of graft body, and distal anastomosis). Two reviewers discriminated optimal reconstruction intervals for each CABG segment in each temporal window. Optimal windows for ETCM were also evaluated. Results: The determined optimal systolic and diastolic reconstruction intervals could be divided into 2 groups with threshold HR=68. The determined best reconstruction intervals for low heart rate (HR<68) and high heart rate (HR>68) were 76.0±2.5% and 45.0±0% respectively. Average image quality scores were 1.7±0.6 with good inter-observer agreement (Kappa=0.79). Image quality was significantly better for saphenous vein grafts versus arterial grafts (P<0.001). The recommended windows of ETCM for low HR, high HR and all HR groups were 40–50%, 71–81% and 40–96% of R-R interval, respectively. The corresponding dose savings were about 60.8%, 58.7% and 22.7% in that order. Conclusions: We determined optimal reconstruction intervals and ETCM windows representing a good compromise between radiation and image quality for following bypass surgery using a 256-slice CT.

  1. Radiation induced graft copolymerization of acrylamide onto poly (3-hydroxybutyrate)

    International Nuclear Information System (INIS)

    Gonzalez Torres, Maykel; Rapado Paneque, Manuel; Paredes Zaldivar, Mayte; Altanes Valentin, Sonia; Barrera Gonzalez, Gisela

    2008-01-01

    The graft copolymer poly (3-hydroxybutyrate)-g- polyacrylamide [P (HB-g-AAm)] was synthesized by radiation induced graft copolymerization of acrylamide onto poly (3-hydroxybutyrate). The study was conducted by the simultaneous irradiation method. The structure of [P (HB-g-AAm)] was identified by Fourier Transform Infrared (FTIR) spectroscopy. Thermal behavior of the graft copolymer was also studied by Thermal Gravimetric Analysis (TGA) and Differential Scanning Calorimetry (DSC). From the results it was found that FTIR studies showed new signals (stretching -N-H) as strong evidence of grafting. The grafting degree was found to be 10 % and the thermodynamic parameter obtained from the DSC thermogram of plain PHB and the graft copolymer varied showing decrease in the material crystallinity and increase in the glass transition temperature. These results demonstrate that the radiation induced graft copolymerization reaction of acrylamide onto PHB was successively achieved. (Author)

  2. [Skin graft, smoking and diabetes mellitus type 2].

    Science.gov (United States)

    Pérez-Guisado, Joaquín; Fidalgo-Rodríguez, Félix T; Gaston, Kate L; Rioja, Luis F; Thomas, Steven J

    2012-01-01

    Smoking and hyperglycemia decrease the success of skin graft survival in specific circumstances. It is well known that smoking and diabetes mellitus (DM) type 2 increase the oxidative and impair the endothelial function. The objective of this retrospective study was to determine if smoking and DM type 2 are factors associated with lower skin graft survival, in different etiologies of the injury associated to the skin loss. It was a bicentric, retrospective, cross sectional case control study, carried out on 2457 medical patients who met the inclusion criteria. It was carried out over a 10 years period between January 2000-December 2009, at Reina Sofía University Hospital (Córdoba, Spain) and UAB Hospital at Birmingham (Alabama, USA). The percentage of successful graft for each group and its control were analyzed by Chi-square test. The confidence interval chosen for statistical differences was 95%. Smoking and DM type 2 decreased the percentage of skin graft survival when compared with their control groups. DM type 2 was associated with greater negative success on skin graft survival than smoking when compared with their control groups. There was a statistically significant drop in skin graft of 18% in smoking group (range: 68-86%) and 25% in DM type 2 group (53-78%). The OR showed a clear association between the risk factors studied and the lower skin graft success, being stronger for DM type 2. In conclusion, DM type 2 and smoking are factors associated to lower skin graft take.

  3. Radiation-induced graft polymerization of acrylic acid onto fluorinated polymers: Pt. 2

    International Nuclear Information System (INIS)

    Abdel-Ghaffar, M.; Hegazy, E.A.; Dessouki, A.M.; El-Sawy, N.M.; El-Assy, N.B.

    1991-01-01

    Radiation induced grafting of acrylic acid onto poly (tetrafluoroethylene-perfluorovinyl ether) (PFA) films was investigated. The grafted films rapidly absorbed Fe 3+ , Co 2+ , Ni 2+ , and Cu 2+ ions in high efficiency. The polyacrylic acid grafted onto PFA acted as a chelating site for the previously selected transition metal ions. Such prepared copolymer-metal complexes were confirmed spectrophotometrically via IR, UV-spectrometry, X-ray fluorescence, X-ray diffraction, and colour index measurements. Electrical conductivity and mechanical properties of PFA grafted copolymer-metal complexes were investigated. The applications of such prepared copolymer-metal complexes in the field of semiconductors besides its performance as a cation-exchange membrane may be of great interest. (author)

  4. Rabbit Calvarial Defect Model for Customized 3D-Printed Bone Grafts.

    Science.gov (United States)

    Lee, Kang-Gon; Lee, Kang-Sik; Kang, Yu-Jeoung; Hwang, Jong-Hyun; Lee, Se-Hwan; Park, Sang-Hyug; Park, Yongdoo; Cho, Young-Sam; Lee, Bu-Kyu

    2018-05-01

    Bone graft materials are commonly used to regenerate various bone defects, but their application is often limited because of the complex defect shape in various clinical conditions. Hence, customized bone grafts using three-dimensional (3D) printing techniques have been developed. However, conventional simple bone defect models are limited for evaluating the benefits and manufacturing accuracy of 3D-printed customized bone grafts. Thus, the aim of the present study was to develop a complex-shaped bone defect model. We designed an 8-shaped bony defect that consists of two simple circles attached to the rabbit calvarium. To determine the critical-sized defect (CSD) of the 8-shaped defects, 5.6- and 7-mm-diameter trephine burs were tested, and the 7-mm-diameter bur could successfully create a CSD, which was easily reproducible on the rabbit calvarium. The rate of new bone formation was 28.65% ± 8.63% at 16 weeks following creation of the defect. To confirm its efficacy for clinical use, the 8-shaped defect was created on a rabbit calvarium and 3D computed tomography (CT) was performed. A stereolithography file was produced using the CT data, and a 3D-printed polycaprolactone graft was fabricated. Using our 8-shaped defect model, we were able to modify the tolerances of the bone graft and calvarial defect to fabricate a more precise bone graft. Customized characteristics of the bone graft were then used to improve the accuracy of the bone graft. In addition, we confirmed the fitting ability of the 3D-printed graft during implantation of the graft. Our 8-shaped defect model on the rabbit calvarium using a 7.0-mm trephine bur may be a useful CSD model for evaluating 3D-printed graft materials.

  5. Influence of alkylphosphonic acid grafting on the electronic and magnetic properties of La{sub 2/3}Sr{sub 1/3}MnO{sub 3} surfaces

    Energy Technology Data Exchange (ETDEWEB)

    Galbiati, Marta [Unité Mixte de Physique CNRS-Thales, 1 Av. A. Fresnel, 91767 Palaiseau (France); Université Paris-Sud, 91405 Orsay (France); Tatay, Sergio, E-mail: sergio.tatay@uv.es [Unité Mixte de Physique CNRS-Thales, 1 Av. A. Fresnel, 91767 Palaiseau (France); Université Paris-Sud, 91405 Orsay (France); Instituto de Ciencia Molecular (ICMol), Universitat de Valencia, C. Caterdratico Jose Beltran 2, 46980 Paterna (Spain); Delprat, Sophie [Unité Mixte de Physique CNRS-Thales, 1 Av. A. Fresnel, 91767 Palaiseau (France); Université Paris-Sud, 91405 Orsay (France); UPMC, Université Paris 06, 4 Place Jussieu, 75005 Paris (France); Barraud, Clément; Cros, Vincent; Jacquet, Eric [Unité Mixte de Physique CNRS-Thales, 1 Av. A. Fresnel, 91767 Palaiseau (France); Université Paris-Sud, 91405 Orsay (France); Coloma, Fernando [Servicios Técnicos de Investigación, Universidad de Alicante, E-03080 Alicante (Spain); Choueikani, Fadi; Otero, Edwige; Ohresser, Philippe [Synchrotron SOLEIL, L’Orme des Merisiers, Saint-Aubin, BP 48, FR-91192 Gif-sur-Yvette (France); Haag, Norman; Cinchetti, Mirko; Aeschlimann, Martin [Department of Physics and Research Center OPTIMAS, University of Kaiserslautern, Erwin-Schroedinger Strasse 46, 67663 Kaiserslautern (Germany); Seneor, Pierre, E-mail: pierre.seneor@thalesgroup.com [Unité Mixte de Physique CNRS-Thales, 1 Av. A. Fresnel, 91767 Palaiseau (France); Université Paris-Sud, 91405 Orsay (France); and others

    2015-10-30

    Highlights: • Probe the influence of alkylphosphonic acids-based SAMs on the electronic and magnetic properties of the LSMO. • Measure the modification of the Mn oxidation state of LSMO surface induced by the molecules grafting. • Evaluate the modification of the LSMO work function induced by the alkylphosphonic acids molecules. - Abstract: Self-assembled monolayers (SAMs) are highly promising materials for molecular engineering of electronic and spintronics devices thanks to their surface functionalization properties. In this direction, alkylphosphonic acids have been used to functionalize the most common ferromagnetic electrode in organic spintronics: La{sub 2/3}Sr{sub 1/3}MnO{sub 3} (LSMO). However, a study on the influence of SAMs grafting on LSMO electronic and magnetic properties is still missing. In this letter, we probe the influence of alkylphosphonic acids-based SAMs on the electronic and magnetic properties of the LSMO surface using different spectroscopies. We observe by X-ray photoemission and X-ray absorption that the grafting of the molecules on the LSMO surface induces a reduction of the Mn oxidation state. Ultraviolet photoelectron spectroscopy measurements also show that the LSMO work function can be modified by surface dipoles opening the door to both tune the charge and spin injection efficiencies in organic devices such as organic light-emitting diodes.

  6. Magnetic resonance angiography in renal grafts. Comparison with color Doppler echography

    International Nuclear Information System (INIS)

    Yanagisawa, Takayoshi; Otsubo, Osamu; Nozaki, Harushige

    1995-01-01

    We studied relationship between magnetic resonance angiography (MRA) of renal graft and renal graft function in 14 renal transplantations (10 from living donors, 4 from cadaveric donors). MRA was performed on 0.3-T permanent magnet system (MRP 7000, HITACHI, JAPAN) using 2 dimensional time of flight technique (FOV: 350 mm 2 , RT: 60 msec, ET: 10 msec, FA: 90deg, Slice: volumes 60, thickness 4 mm, overlap 1 mm). As for parameters of renal graft function, we evaluated color doppler echography (CD) of transplanted renal artery, renal blood flow (RBF), velocity of interlobar artery (ILA) and serum creatinine level (S-Cr). CD, RBF and velocity of ILA were visualized and measured by duplex color doppler echosystem (EUB-565A, HITACHI, JAPAN). Depending on visualization of transplanted renal artery, MRA was graded into 3 groups (MA Grade 3: visualization of ILA, MA Grade 2: visualization of segmental artery and the first branch but no visualization of ILA, MA Grade 1: visualization of main renal artery only). Likewise, visualization of CD was graded into 3 groups (CD Grade 3: good visualization of arcuate artery (AA) and ILA, CD Grade 2: poor visualization of AA but good visualization of ILA, CD Grade 1: poor visualization of ILA). The MRA grading had a very significant correlation (r=0.79, p<0.001) with the CD grading. As for RBF and velocity of ILA, the RBF of MA Grade 3 group (n=8) was significantly (p<0.05) higher than the MA Grade 2 group (n=4) and the MA Grade 1 group (n=2), and the velocity of ILA of MA Grade 3 group was also higher than the above groups but not significantly. Furthermore, the S-Cr of MA Grade 3 was significantly (p<0.05) lower than the others. These results showed that MRA of renal graft had a qualitative index of renal graft function. (author)

  7. Significant prolongation of segmental pancreatic allograft survival in two species

    Energy Technology Data Exchange (ETDEWEB)

    Du Toit, D.F.; Heydenrych, J.J.

    1988-06-01

    A study was conducted to assess the suppression of segmental pancreatic allograft rejection by cyclosporine (CSA) alone in baboons and dogs, and subtotal marrow irradiation (TL1) alone and TL 1 in combination with CSA in baboons. Total pancreatectomy in the dog and primate provided a reliable diabetic model, induced an absolute deficiency of insulin and was uniformly lethal if not treated. Continuous administration of CSA in baboons resulted in modest allograft survival. As in baboons, dogs receiving CSA 25 mg/kg/d rendered moderate graft prolongation but a dose of 40 mg/kg/d resulted in significant graft survival (greater than 100 days) in 5 of 8 allograft recipients. Irradiation alone resulted in minimal baboon pancreatic allograft survival of 20 baboons receiving TL1 1,000 rad and CSA, 3 had graft survival greater than of 100 days. Of 15 baboons receiving TL1 800 rad and CSA, 6 had graft survival of greater than 100 days. In conclusion, CSA administration in dogs and TL1 in combination with CSA in baboons resulted in highly significant segmental pancreatic allograft survival.

  8. Significant prolongation of segmental pancreatic allograft survival in two species

    International Nuclear Information System (INIS)

    Du Toit, D.F.; Heydenrych, J.J.

    1988-01-01

    A study was conducted to assess the suppression of segmental pancreatic allograft rejection by cyclosporine (CSA) alone in baboons and dogs, and subtotal marrow irradiation (TL1) alone and TL 1 in combination with CSA in baboons. Total pancreatectomy in the dog and primate provided a reliable diabetic model, induced an absolute deficiency of insulin and was uniformly lethal if not treated. Continuous administration of CSA in baboons resulted in modest allograft survival. As in baboons, dogs receiving CSA 25 mg/kg/d rendered moderate graft prolongation but a dose of 40 mg/kg/d resulted in significant graft survival (greater than 100 days) in 5 of 8 allograft recipients. Irradiation alone resulted in minimal baboon pancreatic allograft survival of 20 baboons receiving TL1 1,000 rad and CSA, 3 had graft survival greater than of 100 days. Of 15 baboons receiving TL1 800 rad and CSA, 6 had graft survival of greater than 100 days. In conclusion, CSA administration in dogs and TL1 in combination with CSA in baboons resulted in highly significant segmental pancreatic allograft survival

  9. Cartilage Morphological and Histological Findings After Reconstruction of the Glenoid With an Iliac Crest Bone Graft.

    Science.gov (United States)

    Auffarth, Alexander; Resch, Herbert; Matis, Nicholas; Hudelmaier, Martin; Wirth, Wolfgang; Forstner, Rosemarie; Neureiter, Daniel; Traweger, Andreas; Moroder, Philipp

    2018-04-01

    The J-bone graft is presumably representative of iliac crest bone grafts in general and allows anatomic glenoid reconstruction in cases of bone defects due to recurrent traumatic anterior shoulder dislocations. As a side effect, these grafts have been observed to be covered by some soft, cartilage-like tissue when arthroscopy has been indicated after such procedures. To evaluate the soft tissue covering of J-bone grafts by use of magnetic resonance imaging (MRI) and histological analysis. Case series; Level of evidence, 4. Patients underwent MRI at 1 year after the J-bone graft procedures. Radiological data were digitally processed and evaluated by segmentation of axial images. Independent from the MRI analysis, 2 biopsy specimens of J-bone grafts were harvested for descriptive histological analysis. Segmentation of the images revealed that all grafts were covered by soft tissue. This layer had an average thickness of 0.87 mm compared with 1.96 mm at the adjacent native glenoid. Of the 2 biopsy specimens, one exhibited evident hyaline-like cartilage and the other presented patches of chondrocytes embedded in a glycosaminoglycan-rich extracellular matrix. J-bone grafts are covered by soft tissue that can differentiate into fibrous and potentially hyaline cartilage. This feature may prove beneficial for delaying the onset of dislocation arthropathy of the shoulder.

  10. A New and Simple Practical Plane Dividing Hepatic Segment 2 and 3 of the Liver: Evaluation of Its Validity

    International Nuclear Information System (INIS)

    Lee, Ho Yun; Chung, Jin Wook; Lee, Jeong Min; Yoon, Chang Jin; Lee, Whal; Jae, Hwan Jun; Yin, Yong Hu; Kang, Sung Gwon; Park, Jae Hyung

    2007-01-01

    The conventional method of dividing hepatic segment 2 (S2) and 3 (S3) is subjective and CT interpretation is unclear. The purpose of our study was to test the validity of our hypothesis that the actual plane dividing S2 and S3 is a vertical plane of equal distance from the S2 and S3 portal veins in clinical situations. We prospectively performed thin-section iodized-oil CT immediately after segmental chemoembolization of S2 or S3 in 27 consecutive patients and measured the angle of intersegmental plane on sagittal multiplanar reformation (MPR) images to verify its vertical nature. Our hypothetical plane dividing S2 and S3 is vertical and equidistant from the S2 and S3 portal veins (vertical method). To clinically validate this, we retrospectively collected 102 patients with small solitary hepatocellular carcinomas (HCC) on S2 or S3 the segmental location of which was confirmed angiographically. Two reviewers predicted the segmental location of each tumor at CT using the vertical method independently in blind trials. The agreement between CT interpretation and angiographic results was analyzed with Kappa values. We also compared the vertical method with the horizontal one. In MPR images, the average angle of the intersegmental plane was slanted 15 degrees anteriorly from the vertical plane. In predicting the segmental location of small HCC with the vertical method, the Kappa value between CT interpretation and angiographic result was 0.838 for reviewer 1 and 0.756 for reviewer 2. Inter-observer agreement was 0.918. The vertical method was superior to the horizontal method for localization of HCC in the left lobe (p < 0.0001 for reviewers 1 and 2). The proposed vertical plane equidistant from S2 and S3 portal vein is simple to use and useful for dividing S2 and S3 of the liver

  11. 3D Segmentations of Neuronal Nuclei from Confocal Microscope Image Stacks

    Directory of Open Access Journals (Sweden)

    Antonio eLaTorre

    2013-12-01

    Full Text Available In this paper, we present an algorithm to create 3D segmentations of neuronal cells from stacks of previously segmented 2D images. The idea behind this proposal is to provide a general method to reconstruct 3D structures from 2D stacks, regardless of how these 2D stacks have been obtained. The algorithm not only reuses the information obtained in the 2D segmentation, but also attempts to correct some typical mistakes made by the 2D segmentation algorithms (for example, under segmentation of tightly-coupled clusters of cells. We have tested our algorithm in a real scenario --- the segmentation of the neuronal nuclei in different layers of the rat cerebral cortex. Several representative images from different layers of the cerebral cortex have been considered and several 2D segmentation algorithms have been compared. Furthermore, the algorithm has also been compared with the traditional 3D Watershed algorithm and the results obtained here show better performance in terms of correctly identified neuronal nuclei.

  12. Comparison of T1-weighted 2D TSE, 3D SPGR, and two-point 3D Dixon MRI for automated segmentation of visceral adipose tissue at 3 Tesla.

    Science.gov (United States)

    Fallah, Faezeh; Machann, Jürgen; Martirosian, Petros; Bamberg, Fabian; Schick, Fritz; Yang, Bin

    2017-04-01

    To evaluate and compare conventional T1-weighted 2D turbo spin echo (TSE), T1-weighted 3D volumetric interpolated breath-hold examination (VIBE), and two-point 3D Dixon-VIBE sequences for automatic segmentation of visceral adipose tissue (VAT) volume at 3 Tesla by measuring and compensating for errors arising from intensity nonuniformity (INU) and partial volume effects (PVE). The body trunks of 28 volunteers with body mass index values ranging from 18 to 41.2 kg/m 2 (30.02 ± 6.63 kg/m 2 ) were scanned at 3 Tesla using three imaging techniques. Automatic methods were applied to reduce INU and PVE and to segment VAT. The automatically segmented VAT volumes obtained from all acquisitions were then statistically and objectively evaluated against the manually segmented (reference) VAT volumes. Comparing the reference volumes with the VAT volumes automatically segmented over the uncorrected images showed that INU led to an average relative volume difference of -59.22 ± 11.59, 2.21 ± 47.04, and -43.05 ± 5.01 % for the TSE, VIBE, and Dixon images, respectively, while PVE led to average differences of -34.85 ± 19.85, -15.13 ± 11.04, and -33.79 ± 20.38 %. After signal correction, differences of -2.72 ± 6.60, 34.02 ± 36.99, and -2.23 ± 7.58 % were obtained between the reference and the automatically segmented volumes. A paired-sample two-tailed t test revealed no significant difference between the reference and automatically segmented VAT volumes of the corrected TSE (p = 0.614) and Dixon (p = 0.969) images, but showed a significant VAT overestimation using the corrected VIBE images. Under similar imaging conditions and spatial resolution, automatically segmented VAT volumes obtained from the corrected TSE and Dixon images agreed with each other and with the reference volumes. These results demonstrate the efficacy of the signal correction methods and the similar accuracy of TSE and Dixon imaging for automatic volumetry of VAT at 3 Tesla.

  13. Intravascular stent graft with polyurethane and metallic stent: experimental study

    International Nuclear Information System (INIS)

    Do, Young Soo; Lee, Won Jae; Kim, Boo Kyung Han; Park, Jae Hyung; Lee, Hak Jong; Lee, Sang Hyun; Kim, Sung Hyun; Kim, Jong Won; Ha, Jongwon

    1997-01-01

    To evaluate the usefulness of a new model of the stent graft, and of tissue response related to placement of the stent graft. The stent graft was constructed from polyurethane (Pellethane) graft and Hanaro stent(12mm in diameter, 45mm in length, 10 bends). A stent grafts was inserted into the lower thoracic aorta in each of six adult mongrel dogs(body weight, 12-16kg). At one, two, four, and six months, follow-up studies of angiography and spiral CT angiography were preformed to evaluate wascular patency, vascular stenosis, and thrombus formation. Two dogs were sacrificed at 1month, 2months, and 6months after insertion of the stent graft and macroscopic, light microscopic, and scanning electron microscopic examinations of the aortic segment including the stent graft were performed to evaluate intimal hyperplasia, endothelial growth to the graft, and thrombus formation. During follow-up at one, two, four, and six months, angiography or spiral CT angiography showed 20-100% luminal stenosis or occlusion of the lower thoracic aorta by the thrombus and perigraft leaks in three dogs(50%), and collateral vessels caused by occlusion of the aorta in two (33.3%). On gross examination, there were thrombi of 1-5mm thickness at the graft portions in all dogs, and this thickness gradually increased. The mean thickness of intimal hyperplasia at the stent portion gradually increased from 120μm to 227μm and the mean thickness of intimal hyperplasia at the graft portion from 93μm to 914μm. This thickness was greater at the graft portion than at the stent portion. Scanning electron microscopy showed elliptical endothelial lining on the neointimal surfaces at each end of the graft. Thrombi caused stenosis or occlusion of the stent graft. In order for such a graft to be ideal, further study is needed

  14. ST segment elevation after myocardial infarction: Viability or ventricular dysfunction? Comparison with myocardial scintigraphy

    International Nuclear Information System (INIS)

    Chalela, William Azem; Soares, J. Jr.; Meneghetti, J.C.; Olivera, C.G.; Moffa, P.J.; Falcao, A.M.; Ramires, J.A.F.

    2004-01-01

    The detection of viable myocardium after myocardial infarction is an important indication for revascularization. We compared exercise-induced ST segment elevation with reversibility at Thallium-201 SPECT scintigraphy and regional wall motion assessment by ventriculography. Thirty two patients with previous myocardial infarction and with left ventricular ejection fraction of < 50% were studied. Patients underwent coronary angiography and Thallium-201 SPECT scintigraphy with re-injection protocol before and after coronary artery bypass graft surgery. Group I comprised 11 patients with ST segment elevation during treadmill stress testing. Group II comprised 21 patients without ST segment elevation. Minimal or moderate hypokinesis was present in 2 patients of Group I and in 4 patients of Group II. Nine patients of Group I and 17 patients of Group II had severe hypokinetic, akinetic or dyskinetic myocardium. Scintigraphy revealed reversibility in the myocardial infarction area in 4 patients from Group I (36.4%) and 11 (52.4%) patients from Group II. Improvement in perfusion after coronary artery bypass grafting was observed in 4 patients from Group I and 8 patients from Group II. Sensitivity, specificity, accuracy, and positive and negative predictive values of ST segment elevation were 33.3, 70.6, 55.2, 44.5 and 60% respectively. It was concluded that exercise-induced ST segment elevation after myocardial infarction is present more frequently in cases of severe regional myocardial dysfunction. (author)

  15. Fabrication and characterization of a novel hydrophobic CaCO{sub 3} grafted by hydroxylated poly(vinyl chloride) chains

    Energy Technology Data Exchange (ETDEWEB)

    Bao, Lixia [State Key Laboratory of Polymer Materials Engineering, Sichuan University (China); School of Chemical Science and Technology, Yunnan University (China); Yang, Simei; Luo, Xin [School of Chemical Science and Technology, Yunnan University (China); Lei, Jingxin [State Key Laboratory of Polymer Materials Engineering, Sichuan University (China); Cao, Qiue [School of Chemical Science and Technology, Yunnan University (China); Wang, Jiliang, E-mail: jlwang@ynu.edu.cn [School of Chemical Science and Technology, Yunnan University (China)

    2015-12-01

    Highlights: • Hydroxylated poly(vinyl chloride) (PVC-OH) with different molecular weight and hydroxyl value was successfully prepared by the suspension copolymerization. • PVC-OH was grafted onto the surface of CaCO{sub 3} particles by the urethane formation reaction. • The modified CaCO{sub 3} particles show excellent hydrophobicity. - Abstract: The hydroxylated PVC (PVC-OH) was successfully synthesized by a suspension polymerization of vinyl chloride (VC), butyl acrylate (BA) and hydroxyethyl acrylate (HEA). Novel hydrophobic CaCO{sub 3} was then prepared by a urethane formation reaction between methylene diphenyl diisocyanate (MDI) and the −OH groups both in the PVC-OH chains and on the surface of pristine CaCO{sub 3} particles. The effect of the PVC-OH content on the grafting ratio of treated CaCO{sub 3} particles was extensively investigated. Combining the result of Fourier transform infrared (FTIR) with that of water contact angle, it can be concluded that the hydrophobicity of CaCO{sub 3} had been efficiently improved by the PVC-OH segments grafted on the surface of CaCO{sub 3} particles. X-ray diffraction (XRD), thermal gravity analysis (TGA), scanning electron microscope (SEM) and transmission electron microscope (TEM) were also used to study crystalline behaviors, thermal stability and surface morphology of the modified CaCO{sub 3} particles, respectively. The change of specific surface area implying surface modification was investigated as well.

  16. Ion exchange fiber prepared by radiation grafting, (2)

    International Nuclear Information System (INIS)

    Sekiguchi, Hideaki; Fujiwara, Kunio; Fujii, Toshiaki; Takai, Takeshi; Kobayashi, Atsushi

    1991-01-01

    Ion exchange fiber prepared by radiation grafting has the capabilities for wide application as high performance materials. Extensive studies were made to evaluate the ion exchange fiber prepared by radiation grafting for removing some toxic or malodorous gases, continuing from the previous work (presented in Ebara Engng. Review, No. 146), in which the ability of removing ammonia with cation exchange fiber was investigated. The results of this study can be summarized by the following conclusions: (1) Methods of evaluating the ability of removing ammonia, acetaldehyde, and some lower fatty acids in low concentration were established, (2) Besides being effective for the removal of acidic or basic gases, neutral gas such as acetaldehyde can also be removed by adding some functional compounds to the ion exchange fiber, and (3) Ion exchange fiber prepared by radiation grafting is effective as a deodorizing filter. (author)

  17. 3D-Printed Biodegradable Polymeric Vascular Grafts.

    Science.gov (United States)

    Melchiorri, A J; Hibino, N; Best, C A; Yi, T; Lee, Y U; Kraynak, C A; Kimerer, L K; Krieger, A; Kim, P; Breuer, C K; Fisher, J P

    2016-02-04

    Congenital heart defect interventions may benefit from the fabrication of patient-specific vascular grafts because of the wide array of anatomies present in children with cardiovascular defects. 3D printing is used to establish a platform for the production of custom vascular grafts, which are biodegradable, mechanically compatible with vascular tissues, and support neotissue formation and growth. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  18. A grafting from approach to graft polystyrene chains at the surface of graphene nanolayers by RAFT polymerization: Various graft densities from hydroxyl groups

    Energy Technology Data Exchange (ETDEWEB)

    Roghani-Mamaqani, Hossein, E-mail: r.mamaghani@sut.ac.ir [Department of Polymer Engineering, Sahand University of Technology, PO Box 51335-1996, Tabriz (Iran, Islamic Republic of); Khezri, Khezrollah [School of Chemistry, University College of Science, University of Tehran, PO Box 14155-6455, Tehran (Iran, Islamic Republic of)

    2016-01-01

    Graphical abstract: (3-Aminopropyl) triethoxysilane was grafted at the surface of GO in low and high different graft densities to yield GOHAL and GOHAH, respectively. Subsequently, 2-(dodecylthiocarbonothioylthio)-2-methylpropionic acid (RA) was attached at the surface of GOHAL and GOHAH by an amidation reaction to yield GOHRL and GOHRH, respectively. Then, GOHRL and GOHRH were used in grafting from RAFT polymerization of styrene. - Highlights: • A RAFT agent grafted GO was used in grafting from RAFT polymerization of styrene. • The efficiency of RAFT agent attachment at the surface of GO is 41.12% for high density sample. • Polystyrene molecular weight is decreased by the addition of graphene content and also graft density of RAFT agent. - Abstract: (3-Aminopropyl) triethoxysilane was grafted at the surface of GO in low and high different graft densities to yield GOHAL and GOHAH, respectively. Subsequently, 2-(dodecylthiocarbonothioylthio)-2-methylpropionic acid (RA) was attached at the surface of GOHAL and GOHAH by an amidation reaction to yield GOHRL and GOHRH, respectively. Then, GOHRL and GOHRH were used in grafting from RAFT polymerization of styrene. Grafting of APTES and RA was approved by Fourier transform infrared spectroscopy, X-ray photo electron spectroscopy, and Raman spectroscopy. Expansion of graphene interlayer by oxidation and functionalization processes was evaluated by X-ray diffraction. Conversion values of styrene were calculated using gas chromatography. Molecular weight and PDI values of attached polystyrene (PS) chains were studied by size exclusion chromatography. Thermogravimetric analysis was also used to investigate the degradation temperatures, char contents, and graft contents of modifiers and PS chains. GOHRH and GOHRL reach to char content of 55.3 and 45.2% at 600 °C, which shows that weight ratio of modifier (APTES and RA moieties) is 15.3 and 5.2%, respectively. Scanning and transmission electron microscopies show that

  19. Use of superficial peroneal nerve graft for treating peripheral nerve injuries

    Directory of Open Access Journals (Sweden)

    Samuel Ribak

    2016-02-01

    Full Text Available ABSTRACT OBJECTIVE: To evaluate the clinical results from treating chronic peripheral nerve injuries using the superficial peroneal nerve as a graft donor source. METHODS: This was a study on eleven patients with peripheral nerve injuries in the upper limbs that were treated with grafts from the sensitive branch of the superficial peroneal nerve. The mean time interval between the dates of the injury and surgery was 93 days. The ulnar nerve was injured in eight cases and the median nerve in six. There were three cases of injury to both nerves. In the surgery, a longitudinal incision was made on the anterolateral face of the ankle, thus viewing the superficial peroneal nerve, which was located anteriorly to the extensor digitorum longus muscle. Proximally, the deep fascia between the extensor digitorum longus and the peroneal longus muscles was dissected. Next, the motor branch of the short peroneal muscle (one of the branches of the superficial peroneal nerve was identified. The proximal limit of the sensitive branch was found at this point. RESULTS: The average space between the nerve stumps was 3.8 cm. The average length of the grafts was 16.44 cm. The number of segments used was two to four cables. In evaluating the recovery of sensitivity, 27.2% evolved to S2+, 54.5% to S3 and 18.1% to S3+. Regarding motor recovery, 72.7% presented grade 4 and 27.2% grade 3. There was no motor deficit in the donor area. A sensitive deficit in the lateral dorsal region of the ankle and the dorsal region of the foot was observed. None of the patients presented complaints in relation to walking. CONCLUSIONS: Use of the superficial peroneal nerve as a graft source for treating peripheral nerve injuries is safe and provides good clinical results similar to those from other nerve graft sources.

  20. Substitution urethroplasty of complex and long-segment urethral strictures: a rationale for procedure selection.

    Science.gov (United States)

    Xu, Yue-Min; Qiao, Yong; Sa, Ying-Long; Wu, Den-Long; Zhang, Xin-Ru; Zhang, Jion; Gu, Bao-Jun; Jin, San-Bao

    2007-04-01

    We evaluated the applications and outcomes of substitution urethroplasty, using a variety of techniques, in 65 patients with complex, long-segment urethral strictures. From January 1995 to December 2005, 65 patients with complex urethral strictures >8cm in length underwent substitution urethroplasty. Of the 65 patients, 43 underwent one-stage urethral reconstruction using mucosal grafts (28 colonic mucosal graft, 12 buccal mucosal graft, and 3 bladder mucosal graft), 17 patients underwent one-stage urethroplasty using pedicle flaps, and 5 patients underwent staged Johanson's urethroplasty. The mean follow-up time was 4.8 yr (range; 0.8-10 yr), with an overall success rate of 76.92% (50 of 65 cases). Complications developed in 15 patients (23.08%) and included recurrent stricture in 7 (10.77%), urethrocutaneous fistula in 3 (4.62%), coloabdominal fistula in 1 (1.54%), penile chordee in 2 (3.08%), and urethral pseudodiverticulum in 2 (3.08%). Recurrent strictures and urethral pseudodiverticulum were treated successfully with a subsequent procedure, including repeat urethroplasty in six cases and urethrotomy or dilation in three. Coloabdominal fistula was corrected only by dressing change; five patients await further reconstruction. Penile skin, colonic mucosal, and buccal mucosal grafts are excellent materials for substitution urethroplasty. Colonic mucosal graft urethroplasty is a feasible procedure for complicated urethral strictures involving the entire or multiple portions of the urethra and the technique may also be considered for urethral reconstruction in patients in whom other conventional procedures failed.

  1. Performance evaluation of 2D and 3D deep learning approaches for automatic segmentation of multiple organs on CT images

    Science.gov (United States)

    Zhou, Xiangrong; Yamada, Kazuma; Kojima, Takuya; Takayama, Ryosuke; Wang, Song; Zhou, Xinxin; Hara, Takeshi; Fujita, Hiroshi

    2018-02-01

    The purpose of this study is to evaluate and compare the performance of modern deep learning techniques for automatically recognizing and segmenting multiple organ regions on 3D CT images. CT image segmentation is one of the important task in medical image analysis and is still very challenging. Deep learning approaches have demonstrated the capability of scene recognition and semantic segmentation on nature images and have been used to address segmentation problems of medical images. Although several works showed promising results of CT image segmentation by using deep learning approaches, there is no comprehensive evaluation of segmentation performance of the deep learning on segmenting multiple organs on different portions of CT scans. In this paper, we evaluated and compared the segmentation performance of two different deep learning approaches that used 2D- and 3D deep convolutional neural networks (CNN) without- and with a pre-processing step. A conventional approach that presents the state-of-the-art performance of CT image segmentation without deep learning was also used for comparison. A dataset that includes 240 CT images scanned on different portions of human bodies was used for performance evaluation. The maximum number of 17 types of organ regions in each CT scan were segmented automatically and compared to the human annotations by using ratio of intersection over union (IU) as the criterion. The experimental results demonstrated the IUs of the segmentation results had a mean value of 79% and 67% by averaging 17 types of organs that segmented by a 3D- and 2D deep CNN, respectively. All the results of the deep learning approaches showed a better accuracy and robustness than the conventional segmentation method that used probabilistic atlas and graph-cut methods. The effectiveness and the usefulness of deep learning approaches were demonstrated for solving multiple organs segmentation problem on 3D CT images.

  2. Pretransplant soluble CD30 serum concentration does not affect kidney graft outcomes 3 years after transplantation.

    Science.gov (United States)

    Kovač, J; Arnol, M; Vidan Jeras, B; Bren, A F; Kandus, A

    2010-12-01

    An elevated serum concentration of soluble the form of CD30 (sCD30), an activation marker of mainly T(H)2-type cytokines producing T lymphocytes, has been reported as a predictive factor for acute cellular rejection episodes and poor graft outcomes in kidney transplantation. This historic cohort study investigated the association of a pretransplant sCD30 serum concentrations with kidney graft function and graft survival 3 years posttransplantation in adult recipients of deceased donor kidney grafts, treated with monoclonal anti-CD25 antibodies as an induction treatment combined with a cyclosporine (CsA)-based maintenance triple therapy. The pretransplant sera of 296 recipients were tested for sCD30 content using a microsphere flow-cytometry assay. The estimated glomerular filtration rate (eGFR) was determined by the 4-variable Modification of Diet in Renal Disease equation. The incidences of graft loss were calculated with the use of Kaplan-Meier survival analysis and compared using the log-rank test. According to the distribution of the pretransplant sCD30 levels concentration ≥2700 pg/mL was defined as high (n = 146) and concentration sCD30 groups (65 ± 24 vs 67 ± 21 mL/min/1.73 m(2); P = .43); there was no association between the eGFR 3 years after transplantation and the pretransplant sCD30 levels (r(2) = 0.002; P = .49). Graft survival 3 years after transplantation was also not different in the recipients in high and low sCD30 groups (P = .52). In our adult deceased-donor kidney graft recipients, the pretransplant sCD30 serum concentration was not a predictive factor of immunologic risk associated with the kidney graft function 3 years posttransplantation; neither did it affect graft survival 3 years after transplantation. The immunosuppression with anti-CD25 antibodies as an induction treatment combined with the CsA-based maintenance triple therapy could possibly be decisive for our findings. Copyright © 2010 Elsevier Inc. All rights reserved.

  3. Evaluation of multimodal segmentation based on 3D T1-, T2- and FLAIR-weighted images - the difficulty of choosing.

    Science.gov (United States)

    Lindig, Tobias; Kotikalapudi, Raviteja; Schweikardt, Daniel; Martin, Pascal; Bender, Friedemann; Klose, Uwe; Ernemann, Ulrike; Focke, Niels K; Bender, Benjamin

    2018-04-15

    Voxel-based morphometry is still mainly based on T1-weighted MRI scans. Misclassification of vessels and dura mater as gray matter has been previously reported. Goal of the present work was to evaluate the effect of multimodal segmentation methods available in SPM12, and their influence on identification of age related atrophy and lesion detection in epilepsy patients. 3D T1-, T2- and FLAIR-images of 77 healthy adults (mean age 35.8 years, 19-66 years, 45 females), 7 patients with malformation of cortical development (MCD) (mean age 28.1 years,19-40 years, 3 females), and 5 patients with left hippocampal sclerosis (LHS) (mean age 49.0 years, 25-67 years, 3 females) from a 3T scanner were evaluated. Segmentation based on T1-only, T1+T2, T1+FLAIR, T2+FLAIR, and T1+T2+FLAIR were compared in the healthy subjects. Clinical VBM results based on the different segmentation approaches for MCD and for LHS were compared. T1-only segmentation overestimated total intracranial volume by about 80ml compared to the other segmentation methods. This was due to misclassification of dura mater and vessels as GM and CSF. Significant differences were found for several anatomical regions: the occipital lobe, the basal ganglia/thalamus, the pre- and postcentral gyrus, the cerebellum, and the brainstem. None of the segmentation methods yielded completely satisfying results for the basal ganglia/thalamus and the brainstem. The best correlation with age could be found for the multimodal T1+T2+FLAIR segmentation. Highest T-scores for identification of LHS were found for T1+T2 segmentation, while highest T-scores for MCD were dependent on lesion and anatomical location. Multimodal segmentation is superior to T1-only segmentation and reduces the misclassification of dura mater and vessels as GM and CSF. Depending on the anatomical region and the pathology of interest (atrophy, lesion detection, etc.), different combinations of T1, T2 and FLAIR yield optimal results. Copyright © 2017 Elsevier

  4. Ultrasonic Welded Resorbable Mesh (SonicWeld Rx System) in Reconstruction of Segmental Mandibular Defects: Technical Note and Report of 2 Cases.

    Science.gov (United States)

    Shanti, Rabie M; Yampolsky, Andrew; Milles, Maano; Braidy, Hani

    2015-11-01

    The present report describes 2 patients who underwent mandibular reconstruction after segmental mandibulectomy for benign pathology. The potential of an ultrasonic-aided biodegradable system for containment of a nonvascularized bone graft is discussed. Copyright © 2015 American Association of Oral and Maxillofacial Surgeons. Published by Elsevier Inc. All rights reserved.

  5. H3PO4 imbibed polyacrylamide-graft-chitosan frameworks for high-temperature proton exchange membranes

    Science.gov (United States)

    Yuan, Shuangshuang; Tang, Qunwei; He, Benlin; Chen, Haiyan; Li, Qinghua; Ma, Chunqing; Jin, Suyue; Liu, Zhichao

    2014-03-01

    Proton exchange membrane (PEM), transferring protons from anode to cathode, is a key component in a PEM fuel cell. In the current work, a new class of PEMs are synthesized benefiting from the imbibition behavior of three-dimensional (3D) polyacrylamide-graft-chitosan (PAAm-graft-chitosan) frameworks to H3PO4 aqueous solution. Interconnected 3D framework of PAAm-graft-chitosan provides tremendous space for holding proton-conducting H3PO4. The highest anhydrous proton conductivity of 0.13 S cm-1 at 165 °C is obtained. A fuel cell using a thick membrane as a PEM showed a peak power density of 405 mW cm-2 with O2 and H2 as the oxidant and fuel, respectively. Results indicate that the interconnected 3D framework provides superhighway for proton conduction. The valued merits on anhydrous proton conductivity, huge H3PO4 loading, and easy synthesis promise the new membranes to be good alternatives as high-temperature PEMs.

  6. Liver segmentation in contrast enhanced CT data using graph cuts and interactive 3D segmentation refinement methods

    Energy Technology Data Exchange (ETDEWEB)

    Beichel, Reinhard; Bornik, Alexander; Bauer, Christian; Sorantin, Erich [Departments of Electrical and Computer Engineering and Internal Medicine, Iowa Institute for Biomedical Imaging, University of Iowa, Iowa City, Iowa 52242 (United States); Institute for Computer Graphics and Vision, Graz University of Technology, Inffeldgasse 16, A-8010 Graz (Austria); Department of Electrical and Computer Engineering, Iowa Institute for Biomedical Imaging, University of Iowa, Iowa City, Iowa 52242 (United States); Department of Radiology, Medical University Graz, Auenbruggerplatz 34, A-8010 Graz (Austria)

    2012-03-15

    Purpose: Liver segmentation is an important prerequisite for the assessment of liver cancer treatment options like tumor resection, image-guided radiation therapy (IGRT), radiofrequency ablation, etc. The purpose of this work was to evaluate a new approach for liver segmentation. Methods: A graph cuts segmentation method was combined with a three-dimensional virtual reality based segmentation refinement approach. The developed interactive segmentation system allowed the user to manipulate volume chunks and/or surfaces instead of 2D contours in cross-sectional images (i.e, slice-by-slice). The method was evaluated on twenty routinely acquired portal-phase contrast enhanced multislice computed tomography (CT) data sets. An independent reference was generated by utilizing a currently clinically utilized slice-by-slice segmentation method. After 1 h of introduction to the developed segmentation system, three experts were asked to segment all twenty data sets with the proposed method. Results: Compared to the independent standard, the relative volumetric segmentation overlap error averaged over all three experts and all twenty data sets was 3.74%. Liver segmentation required on average 16 min of user interaction per case. The calculated relative volumetric overlap errors were not found to be significantly different [analysis of variance (ANOVA) test, p = 0.82] between experts who utilized the proposed 3D system. In contrast, the time required by each expert for segmentation was found to be significantly different (ANOVA test, p = 0.0009). Major differences between generated segmentations and independent references were observed in areas were vessels enter or leave the liver and no accepted criteria for defining liver boundaries exist. In comparison, slice-by-slice based generation of the independent standard utilizing a live wire tool took 70.1 min on average. A standard 2D segmentation refinement approach applied to all twenty data sets required on average 38.2 min of

  7. Liver segmentation in contrast enhanced CT data using graph cuts and interactive 3D segmentation refinement methods

    International Nuclear Information System (INIS)

    Beichel, Reinhard; Bornik, Alexander; Bauer, Christian; Sorantin, Erich

    2012-01-01

    Purpose: Liver segmentation is an important prerequisite for the assessment of liver cancer treatment options like tumor resection, image-guided radiation therapy (IGRT), radiofrequency ablation, etc. The purpose of this work was to evaluate a new approach for liver segmentation. Methods: A graph cuts segmentation method was combined with a three-dimensional virtual reality based segmentation refinement approach. The developed interactive segmentation system allowed the user to manipulate volume chunks and/or surfaces instead of 2D contours in cross-sectional images (i.e, slice-by-slice). The method was evaluated on twenty routinely acquired portal-phase contrast enhanced multislice computed tomography (CT) data sets. An independent reference was generated by utilizing a currently clinically utilized slice-by-slice segmentation method. After 1 h of introduction to the developed segmentation system, three experts were asked to segment all twenty data sets with the proposed method. Results: Compared to the independent standard, the relative volumetric segmentation overlap error averaged over all three experts and all twenty data sets was 3.74%. Liver segmentation required on average 16 min of user interaction per case. The calculated relative volumetric overlap errors were not found to be significantly different [analysis of variance (ANOVA) test, p = 0.82] between experts who utilized the proposed 3D system. In contrast, the time required by each expert for segmentation was found to be significantly different (ANOVA test, p = 0.0009). Major differences between generated segmentations and independent references were observed in areas were vessels enter or leave the liver and no accepted criteria for defining liver boundaries exist. In comparison, slice-by-slice based generation of the independent standard utilizing a live wire tool took 70.1 min on average. A standard 2D segmentation refinement approach applied to all twenty data sets required on average 38.2 min of

  8. Liver segmentation in contrast enhanced CT data using graph cuts and interactive 3D segmentation refinement methods.

    Science.gov (United States)

    Beichel, Reinhard; Bornik, Alexander; Bauer, Christian; Sorantin, Erich

    2012-03-01

    Liver segmentation is an important prerequisite for the assessment of liver cancer treatment options like tumor resection, image-guided radiation therapy (IGRT), radiofrequency ablation, etc. The purpose of this work was to evaluate a new approach for liver segmentation. A graph cuts segmentation method was combined with a three-dimensional virtual reality based segmentation refinement approach. The developed interactive segmentation system allowed the user to manipulate volume chunks and∕or surfaces instead of 2D contours in cross-sectional images (i.e, slice-by-slice). The method was evaluated on twenty routinely acquired portal-phase contrast enhanced multislice computed tomography (CT) data sets. An independent reference was generated by utilizing a currently clinically utilized slice-by-slice segmentation method. After 1 h of introduction to the developed segmentation system, three experts were asked to segment all twenty data sets with the proposed method. Compared to the independent standard, the relative volumetric segmentation overlap error averaged over all three experts and all twenty data sets was 3.74%. Liver segmentation required on average 16 min of user interaction per case. The calculated relative volumetric overlap errors were not found to be significantly different [analysis of variance (ANOVA) test, p = 0.82] between experts who utilized the proposed 3D system. In contrast, the time required by each expert for segmentation was found to be significantly different (ANOVA test, p = 0.0009). Major differences between generated segmentations and independent references were observed in areas were vessels enter or leave the liver and no accepted criteria for defining liver boundaries exist. In comparison, slice-by-slice based generation of the independent standard utilizing a live wire tool took 70.1 min on average. A standard 2D segmentation refinement approach applied to all twenty data sets required on average 38.2 min of user interaction

  9. FAS grafted superhydrophobic ceramic membrane

    Science.gov (United States)

    Lu, Jun; Yu, Yun; Zhou, Jianer; Song, Lixin; Hu, Xingfang; Larbot, Andre

    2009-08-01

    The hydrophobic properties of γ-Al 2O 3 membrane have been obtained by grafting fluoroalkylsilane (FAS) on the surface of the membrane. The following grafting parameters were studied: the eroding time of the original membrane, the grafting time, the concentration of FAS solution and the multiplicity of grafting. Hydrophobicity of the membranes was characterized by contact angle (CA) measurement. The thermogravimetric analysis (TGA) was used to investigate the weight loss process (25-800 °C) of the fluoroalkylsilane grafted on Al 2O 3 powders under different grafting conditions. The morphologies of the membranes modified under different parameters were examined by field emission scanning electron microscopy (FE-SEM) and the surface roughness (Ra) was measured using white light interferometers. A needle-like structure was observed on the membrane surface after modification, which causes the change of Ra. On the results above, we speculated a model to describe the reaction between FAS and γ-Al 2O 3 membrane surface as well as the formed surface morphology.

  10. Follow-up of coronary artery bypass graft patency: diagnostic efficiency of high-pitch dual-source 256-slice MDCT findings.

    Science.gov (United States)

    Yuceler, Zeyneb; Kantarci, Mecit; Yuce, Ihsan; Kizrak, Yesim; Bayraktutan, Ummugulsum; Ogul, Hayri; Kiris, Adem; Celik, Omer; Pirimoglu, Berhan; Genc, Berhan; Gundogdu, Fuat

    2014-01-01

    Our aim was to evaluate the diagnostic accuracy of 256-slice, high-pitch mode multidetector computed tomography (MDCT) for coronary artery bypass graft (CABG) patency. Eighty-eight patients underwent 256-slice MDCT angiography to evaluate their graft patency after CABG surgery using a prospectively synchronized electrocardiogram in the high-pitch spiral acquisition mode. Effective radiation doses were calculated. We investigated the diagnostic accuracy of high-pitch, low-dose, prospective, electrocardiogram-triggering, dual-source MDCT for CABG patency compared with catheter coronary angiography imaging findings. A total of 215 grafts and 645 vessel segments were analyzed. All graft segments had diagnostic image quality. The proximal and middle graft segments had significantly (P < 0.05) better mean image quality scores (1.18 ± 0.4) than the distal segments (1.31 ± 0.5). Using catheter coronary angiography as the reference standard, high-pitch MDCT had the following sensitivity, specificity, positive predictive value, and negative predictive value of per-segment analysis for detecting graft patency: 97.1%, 99.6%, 94.4%, and 99.8%, respectively. In conclusion, MDCT can be used noninvasively with a lower radiation dose for the assessment of restenosis in CABG patients.

  11. Worldwide Trends in Multi-arterial Coronary Artery Bypass Grafting Surgery 2004-2014: A Tale of 2 Continents.

    Science.gov (United States)

    Schwann, Thomas A; Tatoulis, James; Puskas, John; Bonnell, Mark; Taggart, David; Kurlansky, Paul; Jacobs, Jeffery P; Thourani, Vinod H; O'Brien, Sean; Wallace, Amelia; Engoren, Milo C; Tranbaugh, Robert F; Habib, Robert H

    2017-01-01

    Recent evidence shows that multi-arterial coronary artery bypass grafting (MABG) based on bilateral internal thoracic (BITA) or left internal thoracic (LITA) and radial artery (RA) improves long-term outcomes compared with single arterial coronary artery bypass grafting (SABG) (LITA + saphenous vein graft). How this evidence affected the worldwide use of MABG, if at all, is not well defined. Accordingly, we report 10-year temporal trends of MABG utilization from 2 continents. A study population of 1,683,434 non-emergent, primary, isolated LITA-based coronary artery bypass grafting (CABG) (≥2 grafts) patients was derived from the Society of Thoracic Surgeons (STS) (1,307,528 (79.5%) of 1,644,388 isolated CABG; total 1179 centers) and the Australia New Zealand Cardiothoracic (ANZ) Databases (34,213 (87%) of 39,046 isolated CABG; 24 centers) between 2004 and 2014. Patients were excluded based on the following: (1) no LITA, (2) if arterial grafts were other than RA or ITA, or (3) if grafting data were missing. The 3 MABG groups were LITA + RA, BITA, and BITA + RA, each with or without supplemental vein grafts. Grafting trends and their associated patient demographics were analyzed. SABG (89.3% STS, 51.4% ANZ) was the most common grafting strategy. MABG was most frequently accomplished by LITA + RA: (STS: 6.1%; ANZ: 42.6%), followed by BITA: (STS: 4.1%; ANZ: 4.3%), while ≥3 (BITA + RA) was rare in the STS (0.5%), but more common in ANZ (5.9%). In the STS, between 2004 and 2014, SABG rates systematically increased from 85.2% to 91.7%, BITA grafting was essentially unchanged from 3.6% to 4.3%, while RA use decreased systematically from 10.5% to 3.7%. In the ANZ, SABG rates increased from 17.3% to 51.4%, BITA grafting decreased from 6.3% to 3.6%, while RA grafting decreased from 65.8% to 39.0%. Compared with SABG patients, BITA patients were younger (STS: median age 59 vs 66, P 30 kg/m 2 ) in STS (37% vs 42%, P < 0.001), more obese in ANZ

  12. AUTOMATED CELL SEGMENTATION WITH 3D FLUORESCENCE MICROSCOPY IMAGES.

    Science.gov (United States)

    Kong, Jun; Wang, Fusheng; Teodoro, George; Liang, Yanhui; Zhu, Yangyang; Tucker-Burden, Carol; Brat, Daniel J

    2015-04-01

    A large number of cell-oriented cancer investigations require an effective and reliable cell segmentation method on three dimensional (3D) fluorescence microscopic images for quantitative analysis of cell biological properties. In this paper, we present a fully automated cell segmentation method that can detect cells from 3D fluorescence microscopic images. Enlightened by fluorescence imaging techniques, we regulated the image gradient field by gradient vector flow (GVF) with interpolated and smoothed data volume, and grouped voxels based on gradient modes identified by tracking GVF field. Adaptive thresholding was then applied to voxels associated with the same gradient mode where voxel intensities were enhanced by a multiscale cell filter. We applied the method to a large volume of 3D fluorescence imaging data of human brain tumor cells with (1) small cell false detection and missing rates for individual cells; and (2) trivial over and under segmentation incidences for clustered cells. Additionally, the concordance of cell morphometry structure between automated and manual segmentation was encouraging. These results suggest a promising 3D cell segmentation method applicable to cancer studies.

  13. FAS grafted superhydrophobic ceramic membrane

    Energy Technology Data Exchange (ETDEWEB)

    Lu Jun [School of Material Science and Engineering, Jingdezhen Ceramic Institute, 333001 Jingdezhen (China); Key Laboratory of Inorganic Coating Materials, Shanghai Institute of Ceramics, CAS, 1295 DingXi Road, Shanghai 200050 (China); Yu Yun, E-mail: yunyush@mail.sic.ac.cn [Key Laboratory of Inorganic Coating Materials, Shanghai Institute of Ceramics, CAS, 1295 DingXi Road, Shanghai 200050 (China); Zhou Jianer [School of Material Science and Engineering, Jingdezhen Ceramic Institute, 333001 Jingdezhen (China); Song Lixin; Hu Xingfang [Key Laboratory of Inorganic Coating Materials, Shanghai Institute of Ceramics, CAS, 1295 DingXi Road, Shanghai 200050 (China); Larbot, Andre [Institut Europeen des Membranes, UMR 5635-CNRS, ENSCM, UMII, 1919 Route de Mende 34293, Montpellier Cedex 5 (France)

    2009-08-30

    The hydrophobic properties of {gamma}-Al{sub 2}O{sub 3} membrane have been obtained by grafting fluoroalkylsilane (FAS) on the surface of the membrane. The following grafting parameters were studied: the eroding time of the original membrane, the grafting time, the concentration of FAS solution and the multiplicity of grafting. Hydrophobicity of the membranes was characterized by contact angle (CA) measurement. The thermogravimetric analysis (TGA) was used to investigate the weight loss process (25-800 deg. C) of the fluoroalkylsilane grafted on Al{sub 2}O{sub 3} powders under different grafting conditions. The morphologies of the membranes modified under different parameters were examined by field emission scanning electron microscopy (FE-SEM) and the surface roughness (Ra) was measured using white light interferometers. A needle-like structure was observed on the membrane surface after modification, which causes the change of Ra. On the results above, we speculated a model to describe the reaction between FAS and {gamma}-Al{sub 2}O{sub 3} membrane surface as well as the formed surface morphology.

  14. The avian-origin PB1 gene segment facilitated replication and transmissibility of the H3N2/1968 pandemic influenza virus.

    Science.gov (United States)

    Wendel, Isabel; Rubbenstroth, Dennis; Doedt, Jennifer; Kochs, Georg; Wilhelm, Jochen; Staeheli, Peter; Klenk, Hans-Dieter; Matrosovich, Mikhail

    2015-04-01

    The H2N2/1957 and H3N2/1968 pandemic influenza viruses emerged via the exchange of genomic RNA segments between human and avian viruses. The avian hemagglutinin (HA) allowed the hybrid viruses to escape preexisting immunity in the human population. Both pandemic viruses further received the PB1 gene segment from the avian parent (Y. Kawaoka, S. Krauss, and R. G. Webster, J Virol 63:4603-4608, 1989), but the biological significance of this observation was not understood. To assess whether the avian-origin PB1 segment provided pandemic viruses with some selective advantage, either on its own or via cooperation with the homologous HA segment, we modeled by reverse genetics the reassortment event that led to the emergence of the H3N2/1968 pandemic virus. Using seasonal H2N2 virus A/California/1/66 (Cal) as a surrogate precursor human virus and pandemic virus A/Hong Kong/1/68 (H3N2) (HK) as a source of avian-derived PB1 and HA gene segments, we generated four reassortant recombinant viruses and compared pairs of viruses which differed solely by the origin of PB1. Replacement of the PB1 segment of Cal by PB1 of HK facilitated viral polymerase activity, replication efficiency in human cells, and contact transmission in guinea pigs. A combination of PB1 and HA segments of HK did not enhance replicative fitness of the reassortant virus compared with the single-gene PB1 reassortant. Our data suggest that the avian PB1 segment of the 1968 pandemic virus served to enhance viral growth and transmissibility, likely by enhancing activity of the viral polymerase complex. Despite the high impact of influenza pandemics on human health, some mechanisms underlying the emergence of pandemic influenza viruses still are poorly understood. Thus, it was unclear why both H2N2/1957 and H3N2/1968 reassortant pandemic viruses contained, in addition to the avian HA, the PB1 gene segment of the avian parent. Here, we addressed this long-standing question by modeling the emergence of the H3N2

  15. Repair of a common bile duct defect with a decellularized ureteral graft

    Science.gov (United States)

    Cheng, Yao; Xiong, Xian-Ze; Zhou, Rong-Xing; Deng, Yi-Lei; Jin, Yan-Wen; Lu, Jiong; Li, Fu-Yu; Cheng, Nan-Sheng

    2016-01-01

    AIM To evaluate the feasibility of repairing a common bile duct defect with a decellularized ureteral graft in a porcine model. METHODS Eighteen pigs were randomly divided into three groups. An approximately 1 cm segment of the common bile duct was excised from all the pigs. The defect was repaired using a 2 cm long decellularized ureteral graft over a T-tube (T-tube group, n = 6) or a silicone stent (stent group, n = 6). Six pigs underwent bile duct reconstruction with a graft alone (stentless group). The surviving animals were euthanized at 3 mo. Specimens of the common bile ducts were obtained for histological analysis. RESULTS The animals in the T-tube and stent groups survived until sacrifice. The blood test results were normal in both groups. The histology results showed a biliary epithelial layer covering the neo-bile duct. In contrast, all the animals in the stentless group died due to biliary peritonitis and cholangitis within two months post-surgery. Neither biliary epithelial cells nor accessory glands were observed at the graft sites in the stentless group. CONCLUSION Repair of a common bile duct defect with a decellularized ureteral graft appears to be feasible. A T-tube or intraluminal stent was necessary to reduce postoperative complications. PMID:28082809

  16. Modification of polyetherurethane for biomedical application by radiation-induced grafting. I. Grafting procedure, determination of mechanical properties, and chemical modification of grafted films

    International Nuclear Information System (INIS)

    Jansen, B.; Ellinghorst, G.

    1985-01-01

    Radiation grafting of monomers onto suitable trunk polymers is a useful tool for tailoring new polymers for special purposes. This technique has been used in the past for the development of biocompatible materials, e.g., by grafting hydrogels onto mechanically stable polymers. In this first part of our work, the radiation grafting of hydrophilic or reactive monomers onto a polyetherurethane film using the pre-swelling technique is described. Following this technique the trunk polymer was swollen in the monomer before irradiation. As monomers 2-hydroxyethyl methacrylate (HEMA), 2,3-epoxypropyl methacrylate (GMA), 2,3-dihydroxypropyl methacrylate (GOMA), and acrylamide (AAm) were used. The kinetics of the grafting reactions were examined, and the distribution of the graft component inside the trunk polymer was investigated by means of infrared (IR) spectroscopy. Surface-grafted as well as bulk- and surface-grafted products could be obtained. The mechanical behavior of the grafted films--especially in the water-swollen state--was examined and compared with that of the pure trunk polymer. In nearly all cases it was found that the tensile strength sigma B and the elongation at break epsilon R decreases as the grafting yield increases. Modification of GMA- and AAm-grafted films via chemical reactions was performed to create new functional groups of biomedical interest. In this manner a diol structure, a carboxylic acid structure, and a sulfonic acid group could be introduced in the grafted polymer. The water uptake of such modified films is increased markedly when compared with that of the unmodified samples

  17. Coronary arteries segmentation based on the 3D discrete wavelet transform and 3D neutrosophic transform.

    Science.gov (United States)

    Chen, Shuo-Tsung; Wang, Tzung-Dau; Lee, Wen-Jeng; Huang, Tsai-Wei; Hung, Pei-Kai; Wei, Cheng-Yu; Chen, Chung-Ming; Kung, Woon-Man

    2015-01-01

    Most applications in the field of medical image processing require precise estimation. To improve the accuracy of segmentation, this study aimed to propose a novel segmentation method for coronary arteries to allow for the automatic and accurate detection of coronary pathologies. The proposed segmentation method included 2 parts. First, 3D region growing was applied to give the initial segmentation of coronary arteries. Next, the location of vessel information, HHH subband coefficients of the 3D DWT, was detected by the proposed vessel-texture discrimination algorithm. Based on the initial segmentation, 3D DWT integrated with the 3D neutrosophic transformation could accurately detect the coronary arteries. Each subbranch of the segmented coronary arteries was segmented correctly by the proposed method. The obtained results are compared with those ground truth values obtained from the commercial software from GE Healthcare and the level-set method proposed by Yang et al., 2007. Results indicate that the proposed method is better in terms of efficiency analyzed. Based on the initial segmentation of coronary arteries obtained from 3D region growing, one-level 3D DWT and 3D neutrosophic transformation can be applied to detect coronary pathologies accurately.

  18. Arterial Blood Pressure Induces Transient C4b-Binding Protein in Human Saphenous Vein Grafts.

    Science.gov (United States)

    Kupreishvili, Koba; Meischl, Christof; Vonk, Alexander B A; Stooker, Wim; Eijsman, Leon; Blom, Anna M; Quax, Paul H A; van Hinsbergh, Victor W M; Niessen, Hans W M; Krijnen, Paul A J

    2017-05-01

    Complement is an important mediator in arterial blood pressure-induced vein graft failure. Previously, we noted activation of cell protective mechanisms in human saphenous veins too. Here we have analyzed whether C4b-binding protein (C4bp), an endogenous complement inhibitor, is present in the vein wall. Human saphenous vein segments obtained from patients undergoing coronary artery bypass grafting (n = 55) were perfused in vitro at arterial blood pressure with either autologous blood for 1, 2, 4, or 6 hr or with autologous blood supplemented with reactive oxygen species scavenger N-acetylcysteine. The segments were subsequently analyzed quantitatively for presence of C4bp and complement activation product C3d using immunohistochemistry. Perfusion induced deposition of C3d and C4bp within the media of the vessel wall, which increased reproducibly and significantly over a period of 4 hr up to 3.8% for C3d and 81% for C4bp of the total vessel area. Remarkably after 6 hr of perfusion, the C3d-positive area decreased significantly to 1.3% and the C4bp-positive area to 19% of the total area of the vein. The areas positive for both C4bp and C3d were increased in the presence of N-acetylcysteine. Exposure to arterial blood pressure leads to a transient presence of C4bp in the vein wall. This may be part of a cell-protective mechanism to counteract arterial blood pressure-induced cellular stress and inflammation in grafted veins. Copyright © 2017 Elsevier Inc. All rights reserved.

  19. Automatic segmentation of the wire frame of stent grafts from CT data.

    NARCIS (Netherlands)

    Klein, A.; Vliet, J.A. van der; Oostveen, L.J.; Hoogeveen, Y.L.; Schultze Kool, L.J.; Renema, W.K.J.; Slump, C.H.

    2012-01-01

    Endovascular aortic replacement (EVAR) is an established technique, which uses stent grafts to treat aortic aneurysms in patients at risk of aneurysm rupture. Late stent graft failure is a serious complication in endovascular repair of aortic aneurysms. Better understanding of the motion

  20. Bone response to collagenized xenografts of porcine origin (mp3(®) ) and a bovine bone mineral grafting (4BONE(™) XBM) grafts in tibia defects: experimental study in rabbits.

    Science.gov (United States)

    Calvo-Guirado, José Luis; Aguilar-Salvatierra, Antonio; Ramírez-Fernández, Maria P; Maté Sánchez de Val, José E; Delgado-Ruiz, Rafael Arcesio; Gómez-Moreno, Gerardo

    2016-08-01

    This study aimed to carry out the evaluation of bone response of new bone formation to two different xenografts (bovine and porcine) biomaterials inserted in rabbit tibiae. The study used a total of 20 male New Zealand albino rabbits. They received a total of 40 grafts in the proximal metaphyseal areas of both tibiae. Two biomaterials were evaluated: 20 porcine xenografts, as a bone granulate (OsteoBiol(®) MP3(®) ; Tecnoss srl, Giaveno, Italy), were placed in the proximal metaphyseal area of the right tibia, 20 anorganic bovine bone mineral grafting (4BONE(™) XBM, MIS Implants Inc., BARLEV, Israel) were placed in the left tibia. Following graft insertion, the animals were sacrificed in two groups of 10 animals, after 1 and 4 months, respectively. For each group, biomaterials were analyzed: newly formed bone, residual graft materials and the connective tissue. Histomorphometric, EDX analysis and element mapping were performed at 1 and 4 months after graft insertion. At 4 months after treatment, the bone defects displayed radiological images that showed complete repair of osseous defects. Histomorphometric evaluation showed that for the porcine xenograft, the study averages for newly formed bone represented 84.23 ± 2.9%, while bovine matrix was 79.34 ± 2.1%. For residual graft material, the porcine biomaterial had 11.23 ± 1.7% and the bovine graft 31.56 ± 2.3%. Finally, the connective tissue for MP3 was 10.33 ± 1.8%, while for the 4BONE(™) XBM we obtained 14.34 ± 2.9%. Element analysis revealed higher percentages of Ca (54 ± 9%) and P (35 ± 6%) in the group B than group A and control group (P MP3 material; this supports new bone formation, creates a bridge between borders, and facilitates bone ingrowth in both biomaterials. Furthermore, this study observed partial dissolution of the mineral phase of four bone graft and complete resorption of porcine MP3 biomaterial and its incorporation into the surrounding bone. Depending on

  1. Coronary Arteries Segmentation Based on the 3D Discrete Wavelet Transform and 3D Neutrosophic Transform

    Directory of Open Access Journals (Sweden)

    Shuo-Tsung Chen

    2015-01-01

    Full Text Available Purpose. Most applications in the field of medical image processing require precise estimation. To improve the accuracy of segmentation, this study aimed to propose a novel segmentation method for coronary arteries to allow for the automatic and accurate detection of coronary pathologies. Methods. The proposed segmentation method included 2 parts. First, 3D region growing was applied to give the initial segmentation of coronary arteries. Next, the location of vessel information, HHH subband coefficients of the 3D DWT, was detected by the proposed vessel-texture discrimination algorithm. Based on the initial segmentation, 3D DWT integrated with the 3D neutrosophic transformation could accurately detect the coronary arteries. Results. Each subbranch of the segmented coronary arteries was segmented correctly by the proposed method. The obtained results are compared with those ground truth values obtained from the commercial software from GE Healthcare and the level-set method proposed by Yang et al., 2007. Results indicate that the proposed method is better in terms of efficiency analyzed. Conclusion. Based on the initial segmentation of coronary arteries obtained from 3D region growing, one-level 3D DWT and 3D neutrosophic transformation can be applied to detect coronary pathologies accurately.

  2. Efficacy of duplex ultrasound surveillance after infrainguinal vein bypass may be enhanced by identification of characteristics predictive of graft stenosis development.

    Science.gov (United States)

    Tinder, Chelsey N; Chavanpun, Joe P; Bandyk, Dennis F; Armstrong, Paul A; Back, Martin R; Johnson, Brad L; Shames, Murray L

    2008-09-01

    Controversy regarding the efficacy of duplex ultrasound surveillance after infrainguinal vein bypass led to an analysis of patient and bypass graft characteristics predictive for development of graft stenosis and a decision of secondary intervention. Retrospective analysis of a contemporary, consecutive series of 353 clinically successful infrainguinal vein bypasses performed in 329 patients for critical (n = 284; 80%) or noncritical (n = 69; 20%) limb ischemia enrolled in a surveillance program to identify and repair duplex-detected graft stenosis. Variables correlated with graft stenosis and bypass repair included: procedure indication, conduit type (saphenous vs nonsaphenous vein; reversed vs nonreversed orientation), prior bypass graft failure, postoperative ankle-brachial index (ABI) < 0.85, and interpretation of the first duplex surveillance study as "normal" or "abnormal" based on peak systolic velocity (PSV) and velocity ratio (Vr) criteria. Overall, 126 (36%) of the 353 infrainguinal bypasses had 174 secondary interventions (endovascular, 100; surgery, 74) based on duplex surveillance; resulting in 3-year Kaplan-Meier primary (46%), assisted-primary (80%), and secondary (81%) patency rates. Characteristics predictive of duplex-detected stenosis leading to intervention (PSV: 443 +/- 94 cm/s; Vr: 8.6 +/- 9) were: "abnormal" initial duplex testing indicating moderate (PSV: 180-300 cm/s, Vr: 2-3.5) stenosis (P < .0001), non-single segment saphenous vein conduit (P < .01), warfarin drug therapy (P < .01), and redo bypass grafting (P < .001). Procedure indication, postoperative ABI level, statin drug therapy, and vein conduit orientation were not predictive of graft revision. The natural history of 141 (40%) bypasses with an abnormal first duplex scan differed from "normal" grafts by more frequent (51% vs 24%, P < .001) and earlier (7 months vs 11 months) graft revision for severe stenosis and a lower 3-year assisted primary patency (68% vs 87%; P < .001). In 52

  3. Protein adsorption resistant surface on polymer composite based on 2D- and 3D-controlled grafting of phospholipid moieties

    International Nuclear Information System (INIS)

    Hoshi, Toru; Matsuno, Ryosuke; Sawaguchi, Takashi; Konno, Tomohiro; Takai, Madoka; Ishihara, Kazuhiko

    2008-01-01

    To prepare the biocompatible surface, a phosphorylcholine (PC) group was introduced on this hydroxyl group generated by surface hydrolysis on the polymer composite composed of polyethylene (PE) and poly (vinyl acetate) (PVAc) prepared by supercritical carbon dioxide. Two different procedures such as two-dimensional (2D) modification and three-dimensional (3D) modification were applied to obtain the steady biocompatible surface. 2D modification was that PC groups were directly anchored on the surface of the polymer composite. 3D modification was that phospholipid polymer was grafted from the surface of the polymer composite by surface-initiated atom transfer radical polymerization (SI-ATRP) of 2-methacryloyloxyethyl phosphorylcholine (MPC). The surfaces were characterized by X-ray photoelectron spectroscopy, dynamic water contact angle measurements, and atomic force microscope. The effects of the poly(MPC) chain length on the protein adsorption resistivity were investigated. The protein adsorption on the polymer composite surface with PC groups modified by 2D or 3D modification was significantly reduced as compared with that on the unmodified PE. Further, the amount of protein adsorbed on the 3D modified surface that is poly(MPC)-grafted surface decreased with an increase in the chain length of the poly(MPC). The surface with an arbitrary structure and the characteristic can be constructed by using 2D and 3D modification. We conclude that the polymer composites of PE/PVAc with PC groups on the surface are useful for fabricating biomedical devices due to their good mechanical and surface properties

  4. Single stage circumferential lingual mucosal graft urethroplasty in near obliterative bulbar urethra stricture: A novel technique

    Directory of Open Access Journals (Sweden)

    Umesh Sharma

    2016-01-01

    Full Text Available Aims: This is a prospective study of the use and efficacy of a novel technique of circumferential tubularised lingual mucosal graft (LMG in obliterative and near obliterative bulbar urethral stricture of >2 cm where excisional and augmented anastomotic urethroplasty are not feasible. Materials and Methods: The stenotic urethral segment was opened dorsally in midline and fibrosed urethra was excised taking care to preserve the healthy spongiosum tissue. LMG (av. Length 3 cm was placed from one end of corporal body towards spongy tissue in a circumferential manner. Another LMG was placed in similar manner to deal with longer stricture. The urethra was tubularised over 14 Fr silicone catheter. Results: A total of 12 men, of mean age 47 years underwent this procedure. The mean follow up period was 11 months starting from July 2014 till manuscript submission. Follow up included voiding cystourethrogram at 3 weeks, cystoscopy at 3 months (one patient didn't turned up and subsequent follow up. Mean stricture length was 4.66 cm (range, 3–8.5 cm and mean operative time was 195 min. (range, 160 to 200 min.. The technique was successful (normal voiding with no need for any post-operative procedure in 11(91.6% patients. One patient developed early recurrence at 4 month of surgery and had anastomotic stricture which was successfully managed by direct visual internal urethrotomy. Conclusion: Single stage circumferential tubularised graft urethroplasty is an excellent technique for strictures that include segments of obliterative and near obliterative diseased urethra. It provide a wider neourethra than patch graft urethroplasty.

  5. Single stage circumferential lingual mucosal graft urethroplasty in near obliterative bulbar urethra stricture: A novel technique.

    Science.gov (United States)

    Sharma, Umesh; Yadav, Sher Singh; Tomar, Vinay; Garg, Amit

    2016-01-01

    This is a prospective study of the use and efficacy of a novel technique of circumferential tubularised lingual mucosal graft (LMG) in obliterative and near obliterative bulbar urethral stricture of >2 cm where excisional and augmented anastomotic urethroplasty are not feasible. The stenotic urethral segment was opened dorsally in midline and fibrosed urethra was excised taking care to preserve the healthy spongiosum tissue. LMG (av. Length 3 cm) was placed from one end of corporal body towards spongy tissue in a circumferential manner. Another LMG was placed in similar manner to deal with longer stricture. The urethra was tubularised over 14 Fr silicone catheter. A total of 12 men, of mean age 47 years underwent this procedure. The mean follow up period was 11 months starting from July 2014 till manuscript submission. Follow up included voiding cystourethrogram at 3 weeks, cystoscopy at 3 months (one patient didn't turned up) and subsequent follow up. Mean stricture length was 4.66 cm (range, 3-8.5 cm) and mean operative time was 195 min. (range, 160 to 200 min.). The technique was successful (normal voiding with no need for any post-operative procedure) in 11(91.6%) patients. One patient developed early recurrence at 4 month of surgery and had anastomotic stricture which was successfully managed by direct visual internal urethrotomy. Single stage circumferential tubularised graft urethroplasty is an excellent technique for strictures that include segments of obliterative and near obliterative diseased urethra. It provide a wider neourethra than patch graft urethroplasty.

  6. Evaluation and comparison of 3D intervertebral disc localization and segmentation methods for 3D T2 MR data: A grand challenge.

    Science.gov (United States)

    Zheng, Guoyan; Chu, Chengwen; Belavý, Daniel L; Ibragimov, Bulat; Korez, Robert; Vrtovec, Tomaž; Hutt, Hugo; Everson, Richard; Meakin, Judith; Andrade, Isabel Lŏpez; Glocker, Ben; Chen, Hao; Dou, Qi; Heng, Pheng-Ann; Wang, Chunliang; Forsberg, Daniel; Neubert, Aleš; Fripp, Jurgen; Urschler, Martin; Stern, Darko; Wimmer, Maria; Novikov, Alexey A; Cheng, Hui; Armbrecht, Gabriele; Felsenberg, Dieter; Li, Shuo

    2017-01-01

    The evaluation of changes in Intervertebral Discs (IVDs) with 3D Magnetic Resonance (MR) Imaging (MRI) can be of interest for many clinical applications. This paper presents the evaluation of both IVD localization and IVD segmentation methods submitted to the Automatic 3D MRI IVD Localization and Segmentation challenge, held at the 2015 International Conference on Medical Image Computing and Computer Assisted Intervention (MICCAI2015) with an on-site competition. With the construction of a manually annotated reference data set composed of 25 3D T2-weighted MR images acquired from two different studies and the establishment of a standard validation framework, quantitative evaluation was performed to compare the results of methods submitted to the challenge. Experimental results show that overall the best localization method achieves a mean localization distance of 0.8 mm and the best segmentation method achieves a mean Dice of 91.8%, a mean average absolute distance of 1.1 mm and a mean Hausdorff distance of 4.3 mm, respectively. The strengths and drawbacks of each method are discussed, which provides insights into the performance of different IVD localization and segmentation methods. Copyright © 2016 Elsevier B.V. All rights reserved.

  7. Isotropic 3D cardiac cine MRI allows efficient sparse segmentation strategies based on 3D surface reconstruction.

    Science.gov (United States)

    Odille, Freddy; Bustin, Aurélien; Liu, Shufang; Chen, Bailiang; Vuissoz, Pierre-André; Felblinger, Jacques; Bonnemains, Laurent

    2018-05-01

    Segmentation of cardiac cine MRI data is routinely used for the volumetric analysis of cardiac function. Conventionally, 2D contours are drawn on short-axis (SAX) image stacks with relatively thick slices (typically 8 mm). Here, an acquisition/reconstruction strategy is used for obtaining isotropic 3D cine datasets; reformatted slices are then used to optimize the manual segmentation workflow. Isotropic 3D cine datasets were obtained from multiple 2D cine stacks (acquired during free-breathing in SAX and long-axis (LAX) orientations) using nonrigid motion correction (cine-GRICS method) and super-resolution. Several manual segmentation strategies were then compared, including conventional SAX segmentation, LAX segmentation in three views only, and combinations of SAX and LAX slices. An implicit B-spline surface reconstruction algorithm is proposed to reconstruct the left ventricular cavity surface from the sparse set of 2D contours. All tested sparse segmentation strategies were in good agreement, with Dice scores above 0.9 despite using fewer slices (3-6 sparse slices instead of 8-10 contiguous SAX slices). When compared to independent phase-contrast flow measurements, stroke volumes computed from four or six sparse slices had slightly higher precision than conventional SAX segmentation (error standard deviation of 5.4 mL against 6.1 mL) at the cost of slightly lower accuracy (bias of -1.2 mL against 0.2 mL). Functional parameters also showed a trend to improved precision, including end-diastolic volumes, end-systolic volumes, and ejection fractions). The postprocessing workflow of 3D isotropic cardiac imaging strategies can be optimized using sparse segmentation and 3D surface reconstruction. Magn Reson Med 79:2665-2675, 2018. © 2017 International Society for Magnetic Resonance in Medicine. © 2017 International Society for Magnetic Resonance in Medicine.

  8. Effect of fibrin glue derived from snake venom on the viability of autogenous split-thickness skin graft

    Directory of Open Access Journals (Sweden)

    S.C. Rahal

    2004-01-01

    Full Text Available The aim of this study was to analyze the effect of snake venom derived from fibrin glue on the viability of split-thickness skin graft. Nine crossbreed dogs were used. Full-thickness skin segments measuring 4 x 4 cm were bilaterally excised from the proximal radial area on each dog. A split-thickness skin graft was harvestedfrom left lateral thoracic area using a freehand graft knife, and was secured to the left recipient bed using several simple interrupted sutures of 3-0 nylon (sutured graft. A split-thickness skin graft was harvested from the right lateral thoracic area using a graft knife. Fibrin glue derived from snake venom was applied to the recipient bed, and 8 equidistant simple interrupted sutures of 3-0 nylon were used to secure the skin graft (glued graft. Viable and nonviable areas were traced on a transparent sheet and measured using a Nikon Photomicroscope connected to a KS-300 image analysis system. The skin graft and recipient bed were collected from three dogs at day 7, 15, and 30 postoperative. The glued grafts had statistically higher graft viability than sutured grafts. Histological examination showed that the tissue repair process in the glued grafts was more accentuated than sutured grafts. It was possible to conclude that fibrin glue derived from snake venom increased survival of autogenous split-thickness skin graft.

  9. Vascular Endothelial Growth Factor Improves Physico-Mechanical Properties and Enhances Endothelialization of Poly(3-hydroxybutyrate-co-3-hydroxyvalerate)/Poly(ε-caprolactone) Small-Diameter Vascular Grafts In vivo.

    Science.gov (United States)

    Antonova, Larisa V; Sevostyanova, Victoria V; Kutikhin, Anton G; Mironov, Andrey V; Krivkina, Evgeniya O; Shabaev, Amin R; Matveeva, Vera G; Velikanova, Elena A; Sergeeva, Evgeniya A; Burago, Andrey Y; Vasyukov, Georgiy Y; Glushkova, Tatiana V; Kudryavtseva, Yuliya A; Barbarash, Olga L; Barbarash, Leonid S

    2016-01-01

    The combination of a natural polymer poly(3-hydroxybutyrate-co-3-hydroxyvalerate) (PHBV) and a synthetic hydrophobic polymer poly(ε-caprolactone) (PCL) is promising for the preparation of biodegradable and biocompatible small-diameter vascular grafts for bypass surgery. However, physico-mechanical properties and endothelialization rate of PHBV/PCL grafts are poor. We suggested that incorporation of vascular endothelial growth factor (VEGF) into PHBV/PCL grafts may improve their physico-mechanical properties and enhance endothelialization. Here we compared morphology, physico-mechanical properties, and in vivo performance of electrospun small-diameter vascular grafts prepared from PHBV/PCL with and without VEGF. Structure of the graft surface and physico-mechanical properties were examined by scanning electron microscopy and universal testing machine, respectively. Grafts were implanted into rat abdominal aorta for 1, 3, and 6 months with the further histological, immunohistochemical, and immunofluorescence examination. PHBV/PCL grafts with and without VEGF were highly porous and consisted mostly of nanoscale and microscale fibers, respectively. Mean pore diameter and mean pore area were significantly lower in PHBV/PCL/VEGF compared to PHBV/PCL grafts (1.47 μm and 10.05 μm(2); 2.63 μm and 47.13 μm(2), respectively). Durability, elasticity, and stiffness of PHBV/PCL grafts with VEGF were more similar to internal mammary artery compared to those without, particularly 6 months postimplantation. Both qualitative examination and quantitative image analysis showed that three-fourths of PHBV/PCL grafts with VEGF were patent and had many CD31-, CD34-, and vWF-positive cells at their inner surface. However, all PHBV/PCL grafts without VEGF were occluded and had no or a few CD31-positive cells at the inner surface. Therefore, VEGF enhanced endothelialization and improved graft patency at all the time points in a rat abdominal aorta replacement model. In conclusion, PHBV

  10. Microsurgical replantation of a small segment of thumb volar skin.

    Science.gov (United States)

    Akyürek, Mustafa; Safak, Tunç

    2004-06-01

    This report presents a case of microsurgical replantation of a volar skin segment of the thumb. In a 24-year-old patient, a heavy object falling over the dominant thumb resulted in a crush-avulsion injury of a pure skin segment measuring 4 x 2 cm. Examination revealed that the distal fingertip as well as the bone-tendon structures remained intact. Exploration demonstrated that both neurovascular bundles were included in the avulsed skin segment. Microsurgical replantation was achieved successfully, repairing the radial digital artery at both ends with vein grafts as well as anastomosing a palmar vein. Both digital nerves were coapted proximally and distally. An excellent functional and cosmetic result was accomplished with a good sensory recovery. The authors conclude that microsurgical replantation should be attempted in cases of more proximal pure skin avulsions, even if the injury spares distal fingertip tissue or bone-tendon units. In such cases, replantation is superior to any other method of reconstruction. Liberal use of vein grafts is crucial to achieve success.

  11. Development of Graft-Site Candidiasis in 3 Solid Organ Transplant Recipients from the Same Donor.

    Science.gov (United States)

    El-Bandar, Nasrin; Kroy, Daniela C; Fuller, Tom Florian; Kramer, Jürgen; Liefeldt, Lutz; Budde, Klemens; Blobel, Conrad; Miller, Kurt; Friedersdorff, Frank

    2017-07-11

    BACKGROUND Graft-site candidiasis rarely develops in solid organ transplant recipients; however, severe life-threatening complications can occur. We report the course of 3 solid organ transplant recipients developing graft-site candidiasis. CASE REPORT All grafts, consisting of 2 kidneys and 1 liver, were procured from a single donor. Patient data were collected from our database. Candida albicans was isolated from a swab taken during multiple-organ recovery. Complications associated with candidiasis occurred in all 3 recipients with preservation of the liver transplant. Both renal transplant recipients had vascular complications, eventually resulting in graft nephrectomy and subsequent return to dialysis. The patients recovered completely without residual effects of their prior fungal infection. CONCLUSIONS Fungal infections in solid organ transplant recipients are rare. Since the sequelae of these infections are serious and usually pertain to more than 1 recipient at a time, antifungal prophylaxis may be warranted in select donors.

  12. Angiographic predictors of 3-year patency of bypass grafts implanted on the right coronary artery system: a prospective randomized comparison of gastroepiploic artery, saphenous vein, and right internal thoracic artery grafts.

    Science.gov (United States)

    Glineur, David; D'hoore, William; de Kerchove, Laurent; Noirhomme, Philippe; Price, Joel; Hanet, Claude; El Khoury, Gebrine

    2011-11-01

    Saphenous vein, in situ right gastroepiploic artery, and right internal thoracic artery grafts are routinely used to revascularize the right coronary artery. Little is known about the predictive value of objective preoperative angiographic parameters on midterm graft patency. We prospectively enrolled 210 consecutive patients undergoing coronary revascularization. Revascularization of the right coronary artery was randomly performed with the saphenous vein grafts in 81 patients and the right gastroepiploic artery in 92 patients. During the same study period, 37 patients received right coronary artery revascularization with the right internal thoracic artery used in a Y-composite fashion. All patients underwent a protocol-driven coronary angiogram 3 years after surgery. Preoperative angiographic parameters included minimum lumen diameter percent stenosis measured by quantitative angiography. A graft was considered "not functional" with patency scores of 0 to 2 and "functional" with patency scores of 3 or 4. Angiographic follow-up was 100% complete. A significant difference in the distribution of flow patterns was observed in the 3 groups. In multivariate analysis, the use of a saphenous vein graft was associated with superior graft functionality compared with the other conduits (odds ratio, 6.1; 95% confidence interval, 2.4-15). Graft function was negatively influenced by the minimum lumen diameter (odds ratio, 0.11; confidence interval, 0.05-0.25). In the right gastroepiploic artery and right internal thoracic artery groups, the proportion of functional grafts was higher when the minimum lumen diameter was below a threshold value in the third minimum lumen diameter quartile (0.64-1.30 mm). Preoperative angiography predicts graft patency in the right gastroepiploic artery and right internal thoracic artery, whereas the flow pattern in saphenous vein grafts is significantly less influenced by quantitative angiographic parameters. Copyright © 2011 The American

  13. Suction blister grafting - Modifications for easy harvesting and grafting

    Directory of Open Access Journals (Sweden)

    2012-01-01

    Full Text Available Suction blister grafting is a simple modality of treatment of patients with resistant and stable vitiligo. But raising the blisters may be time consuming and transferring to the recipient site may be difficult as the graft is ultrathin. By doing some modifications we can make the technique simpler and easier. We can decrease the blister induction time by intradermal injection of saline, exposure to Wood′s lamp, intrablister injection of saline. By these methods we can decrease the blister induction time from 2-3 hrs to 45-90 minutes. After harvesting the graft, it can be transferred to the recipient area by taking the graft on a sterile glass slide, on the gloved finger, rolling the graft over a sterile syringe and then spreading on the recipient area, or taking on the sterile wrapper of paraffin dressing and then placing over the recipient area.

  14. Either brain-derived neurotrophic factor or neurotrophin-3 only neurotrophin-producing grafts promote locomotor recovery in untrained spinalized cats.

    Science.gov (United States)

    Ollivier-Lanvin, Karen; Fischer, Itzhak; Tom, Veronica; Houlé, John D; Lemay, Michel A

    2015-01-01

    Background. Transplants of cellular grafts expressing a combination of 2 neurotrophic factors, brain-derived neurotrophic factor (BDNF) and neurotrophin-3 (NT-3) have been shown to promote and enhance locomotor recovery in untrained spinalized cats. Based on the time course of recovery and the absence of axonal growth through the transplants, we hypothesized that recovery was due to neurotrophin-mediated plasticity within the existing locomotor circuitry of the lumbar cord. Since BDNF and NT-3 have different effects on axonal sprouting and synaptic connectivity/strengthening, it becomes important to ascertain the contribution of each individual neurotrophins to recovery. Objective. We studied whether BDNF or NT-3 only producing cellular grafts would be equally effective at restoring locomotion in untrained spinal cats. Methods. Rat fibroblasts secreting one of the 2 neurotrophins were grafted into the T12 spinal transection site of adult cats. Four cats in each group (BDNF alone or NT-3 alone) were evaluated. Locomotor recovery was tested on a treadmill at 3 and 5 weeks post-transection/grafting. Results. Animals in both groups were capable of plantar weight-bearing stepping at speed up to 0.8 m/s as early as 3 weeks and locomotor capabilities were similar at 3 and 5 weeks for both types of graft. Conclusions. Even without locomotor training, either BDNF or NT-3 only producing grafts promote locomotor recovery in complete spinal animals. More clinically applicable delivery methods need to be developed. © The Author(s) 2014.

  15. Meniscal allograft transplantation. Part 1: systematic review of graft biology, graft shrinkage, graft extrusion, graft sizing, and graft fixation.

    Science.gov (United States)

    Samitier, Gonzalo; Alentorn-Geli, Eduard; Taylor, Dean C; Rill, Brian; Lock, Terrence; Moutzouros, Vasilius; Kolowich, Patricia

    2015-01-01

    To provide a systematic review of the literature regarding five topics in meniscal allograft transplantation: graft biology, shrinkage, extrusion, sizing, and fixation. A systematic literature search was conducted using the PubMed (MEDLINE), ScienceDirect, and EBSCO-CINAHL databases. Articles were classified only in one topic, but information contained could be reported into other topics. Information was classified according to type of study (animal, in vitro human, and in vivo human) and level of evidence (for in vivo human studies). Sixty-two studies were finally included: 30 biology, 3 graft shrinkage, 11 graft extrusion, 17 graft size, and 6 graft fixation (some studies were categorized in more than one topic). These studies corresponded to 22 animal studies, 22 in vitro human studies, and 23 in vivo human studies (7 level II, 10 level III, and 6 level IV). The principal conclusions were as follows: (a) Donor cells decrease after MAT and grafts are repopulated with host cells form synovium; (b) graft preservation alters collagen network (deep freezing) and causes cell apoptosis with loss of viable cells (cryopreservation); (c) graft shrinkage occurs mainly in lyophilized and gamma-irradiated grafts (less with cryopreservation); (d) graft extrusion is common but has no clinical/functional implications; (e) overall, MRI is not superior to plain radiograph for graft sizing; (f) graft width size matching is more important than length size matching; (g) height appears to be the most important factor influencing meniscal size; (h) bone fixation better restores contact mechanics than suture fixation, but there are no differences for pullout strength or functional results; and (i) suture fixation has more risk of graft extrusion compared to bone fixation. Systematic review of level II-IV studies, Level IV.

  16. Histologic Evaluation of Critical Size Defect Healing With Natural and Synthetic Bone Grafts in the Pigeon ( Columba livia ) Ulna.

    Science.gov (United States)

    Tunio, Ahmed; Jalila, Abu; Goh, Yong Meng; Shameha-Intan; Shanthi, Ganabadi

    2015-06-01

    Fracture and bone segment loss are major clinical problems in birds. Achieving bone formation and clinical union in a fracture case is important for the survival of the bird. To evaluate the efficacy of bone grafts for defect healing in birds, 2 different bone grafts were investigated in the healing of a bone defect in 24 healthy pigeons ( Columba livia ). In each bird, a 1-cm critical size defect (CSD) was created in the left ulna, and the fracture was stabilized with external skeletal fixation (ESF). A graft of hydroxyapatite (HA) alone (n = 12 birds) or demineralized bone matrix (DBM) combined with HA (n = 12 birds) was implanted in the CSD. The CSD healing was evaluated at 3 endpoints: 3, 6, and 12 weeks after surgery. Four birds were euthanatized at each endpoint from each treatment group, and bone graft healing in the ulna CSD was evaluated by histologic examination. The CSD and graft implants were evaluated for quality of union, cortex development, and bone graft incorporation. Results showed no graft rejection in any bird, and all birds had connective tissue formation in the defect because of the bone graft application. These results suggest that bone defect healing can be achieved by a combination of osteoinductive and osteoconductive bone graft materials for clinical union and new bone regeneration in birds. The combination of DBM and HA resulted in a better quality bone graft (P < .05) than did HA alone, but there was no significant differences in cortex development or bone graft incorporation at 3, 6, or 12 weeks. From the results of this study, we conclude that HA bone grafts, alone or in combination with DBM, with external skeletal fixation is suitable and safe for bone defect and fracture treatment in pigeons.

  17. Reconstruction of irradiated bone segmental defects with a biomaterial associating MBCP+(R), microstructured collagen membrane and total bone marrow grafting: an experimental study in rabbits.

    Science.gov (United States)

    Jégoux, Franck; Goyenvalle, Eric; Cognet, Ronan; Malard, Olivier; Moreau, Francoise; Daculsi, Guy; Aguado, Eric

    2009-12-15

    The bone tissue engineering models used today are still a long way from any oncologic application as immediate postimplantation irradiation would decrease their osteoinductive potential. The aim of this study was to reconstruct a segmental critical size defect in a weight-bearing bone irradiated after implantation. Six white New Zealand rabbits were immediately implanted with a biomaterial associating resorbable collagen membrane EZ(R) filled and micro-macroporous biphasic calcium phosphate granules (MBCP+(R)). After a daily schedule of radiation delivery, and within 4 weeks, a total autologous bone marrow (BM) graft was injected percutaneously into the center of the implant. All the animals were sacrificed at 16 weeks. Successful osseous colonization was found to have bridged the entire length of the defects. Identical distribution of bone ingrowth and residual ceramics at the different levels of the implant suggests that the BM graft plays an osteoinductive role in the center of the defect. Periosteum-like formation was observed at the periphery, with the collagen membrane most likely playing a role. This model succeeded in bridging a large segmental defect in weight-bearing bone with immediate postimplantation fractionated radiation delivery. This has significant implications for the bone tissue engineering approach to patients with cancer-related bone defects.

  18. Graft copolymerization of N-vinyl-2-pyrrolidone onto pre-irradiated poly(vinylidene fluoride) powder

    International Nuclear Information System (INIS)

    Xu Chenqi; Huang Wei; Zhou Yongfeng; Yan Deyue; Chen Shutao; Huang Hua

    2012-01-01

    Graft copolymerization of N-vinyl-2-pyrrolidone (NVP) onto 60 Co γ-ray pre-irradiated poly (vinylidene fluoride) (PVDF) powder was investigated to find out the relationship between the degree of grafting (DG) and various factors, including monomer concentration, irradiation dose, reaction time, catalyst and so on. The DG can be calculated by comparing the amount of nitrogen element in the resulting copolymer (PVDF-g-PVP) powder with that in PVP on the basis of element analysis. The presence of PVP in the resulting PVDF powder was confirmed by the comparative studies of pristine PVDF and grafted PVDF powder through Fourier transform infrared (FTIR) spectroscopy, nuclear magnetic resonance (NMR), X-ray photoelectron spectroscopy (XPS), thermo gravimetric analyzer (TGA) and differential scanning calorimetry (DSC), respectively. When the reaction was performed at the monomer concentration of 20% (vol.) and the absorbed dose of 40 kGy for 3 h in water, the max. DG of 17.7% was obtained. - Highlights: ► We modify pristine PVDF powders with NVP by the pre-irradiated graft polymerization. ► The various factors influencing the degree of grafting are investigated in detail. ► The optimal condition of graft polymerization is obtained. ► The polymerization is processed at 20% (vol.) of NVP and 40kGy for 3 hours in water. ► The maximum degree of grafting is 17.7 % at such a condition.

  19. Development and validation of technique for in-vivo 3D analysis of cranial bone graft survival

    Science.gov (United States)

    Bernstein, Mark P.; Caldwell, Curtis B.; Antonyshyn, Oleh M.; Ma, Karen; Cooper, Perry W.; Ehrlich, Lisa E.

    1997-05-01

    Bone autografts are routinely employed in the reconstruction of facial deformities resulting from trauma, tumor ablation or congenital malformations. The combined use of post- operative 3D CT and SPECT imaging provides a means for quantitative in vivo evaluation of bone graft volume and osteoblastic activity. The specific objectives of this study were: (1) Determine the reliability and accuracy of interactive computer-assisted analysis of bone graft volumes based on 3D CT scans; (2) Determine the error in CT/SPECT multimodality image registration; (3) Determine the error in SPECT/SPECT image registration; and (4) Determine the reliability and accuracy of CT-guided SPECT uptake measurements in cranial bone grafts. Five human cadaver heads served as anthropomorphic models for all experiments. Four cranial defects were created in each specimen with inlay and onlay split skull bone grafts and reconstructed to skull and malar recipient sites. To acquire all images, each specimen was CT scanned and coated with Technetium doped paint. For purposes of validation, skulls were landmarked with 1/16-inch ball-bearings and Indium. This study provides a new technique relating anatomy and physiology for the analysis of cranial bone graft survival.

  20. Repair of segmental bone defect using Totally Vitalized tissue engineered bone graft by a combined perfusion seeding and culture system.

    Directory of Open Access Journals (Sweden)

    Lin Wang

    Full Text Available BACKGROUND: The basic strategy to construct tissue engineered bone graft (TEBG is to combine osteoblastic cells with three dimensional (3D scaffold. Based on this strategy, we proposed the "Totally Vitalized TEBG" (TV-TEBG which was characterized by abundant and homogenously distributed cells with enhanced cell proliferation and differentiation and further investigated its biological performance in repairing segmental bone defect. METHODS: In this study, we constructed the TV-TEBG with the combination of customized flow perfusion seeding/culture system and β-tricalcium phosphate (β-TCP scaffold fabricated by Rapid Prototyping (RP technique. We systemically compared three kinds of TEBG constructed by perfusion seeding and perfusion culture (PSPC method, static seeding and perfusion culture (SSPC method, and static seeding and static culture (SSSC method for their in vitro performance and bone defect healing efficacy with a rabbit model. RESULTS: Our study has demonstrated that TEBG constructed by PSPC method exhibited better biological properties with higher daily D-glucose consumption, increased cell proliferation and differentiation, and better cell distribution, indicating the successful construction of TV-TEBG. After implanted into rabbit radius defects for 12 weeks, PSPC group exerted higher X-ray score close to autograft, much greater mechanical property evidenced by the biomechanical testing and significantly higher new bone formation as shown by histological analysis compared with the other two groups, and eventually obtained favorable healing efficacy of the segmental bone defect that was the closest to autograft transplantation. CONCLUSION: This study demonstrated the feasibility of TV-TEBG construction with combination of perfusion seeding, perfusion culture and RP technique which exerted excellent biological properties. The application of TV-TEBG may become a preferred candidate for segmental bone defect repair in orthopedic and

  1. 2,2,2-Trifluoroethyl methacrylate-graft-natural rubber: Synthesis and application as compatibilizer in natural rubber/fluoroelastomer blends

    Energy Technology Data Exchange (ETDEWEB)

    Hinchiranan, N., E-mail: nhn78@hotmail.com [Department of Chemical Technology, Faculty of Science, Chulalongkorn University, Bangkok 10330 (Thailand); Wannako, P. [Program in Petrochemistry and Polymer Science, Faculty of Science, Chulalongkorn University, Bangkok 10330 (Thailand); Paosawatyanyong, B. [Department of Physics, Faculty of Science, Chulalongkorn University, Bangkok 10330 (Thailand); Prasassarakich, P. [Department of Chemical Technology, Faculty of Science, Chulalongkorn University, Bangkok 10330 (Thailand)

    2013-05-15

    The incompatibility and immiscibility of natural rubber (NR)/fluoroelastomers (FKM) blends were improved by incorporation of a graft copolymer synthesized from the free radical graft copolymerization of 2,2,2-trifluoroethyl methacrylate (TFEM) onto NR initiated by benzoyl peroxide via a melt-mixing process. The grafting properties were investigated as functions of the initiator and monomer concentrations, reaction temperature and time. At the optimal conditions, the obtained graft NR (GNR) purified by Soxhlet extraction contained a maximum grafting efficiency of 1.34% with 49.1% monomer conversion. The structure of the purified GNR was analyzed using attenuated total reflectance Fourier transform infrared spectroscopy (ATR-FTIR) and nuclear magnetic resonance spectroscopy ({sup 1}H NMR and {sup 19}F NMR). The gross GNR was then applied as the compatibilizer for NR/FKM vulcanizates (20/80 (w/w)) cured by peroxide vulcanization. The addition of GNR at 15 parts per hundred of rubber (phr) gave a vulcanizate with the highest tensile strength (9.93 MPa), some 5.31-fold higher than that of the incompatibilized one (1.87 MPa). This is likely to be due to the higher degree of homogeneity of the constituent phases in the GNR-compatibilized blends, as observed by scanning electron microscopy (SEM). The GNR-compatibilized NR/FKM vulcanizates were also resistant to gasohol E85 (85% (w/w) of ethanol). Highlights: ► 2,2,2-Trifluoroethyl methacrylate could be grafted on NR via melt-mixing process. ► Effect of grafting parameters on grafting efficiency and gel content was observed. ► NR/FKM containing graft NR had higher tensile strength than uncompatibilized ones. ► The compatibilized NR/FKM vulcanizates had higher gasohol-swelling resistance.

  2. Thrombin immobilization to methacrylic acid grafted poly(3-hydroxybutyrate) and its in vitro application.

    Science.gov (United States)

    Akkaya, Alper; Pazarlioglu, Nurdan

    2013-01-01

    Poly(3-hydroxybutyrate) is nontoxic and biodegradable, with good biocompatibility and potential support for long-term implants. For this reason, it is a good support for enzyme immobilization. Enzyme immobilization could not be done directly because poly(3-hydroxybutyrate) has no functional groups. Therefore, modification should be done for enzyme immobilization. In this study, methacrylic acid was graft polymerized to poly(3-hydroxybutyrate) and thrombin was immobilized to polymethacrylic acid grafted poly(3-hydroxybutyrate). In fact, graft polymerization of methacrylic acid to poly(3-hydroxybutyrate) and thrombin immobilization was a model study. Biomolecule immobilized poly(3-hydroxybutyrate) could be used as an implant. Thrombin was selected as a biomolecule for this model study and it was immobilized to methacrylic acid grafted poly(3-hydroxybutyrate). Then the developed product was used to stop bleeding.

  3. In vitro model for human endothelial cell seeding of a small diameter vascular graft

    International Nuclear Information System (INIS)

    Kent, K.C.; Oshima, A.; Ikemoto, T.; Whittemore, A.D.

    1988-01-01

    A precise system was devised to measure the kinetics of attachment of human venous endothelium to a variety of materials and substrates. Cells were labelled in a postconfluent state with tritiated thymidine, harvested, and a cell suspension seeded into a 4 mm PTFE graft. After a 90 minute incubation period, one half of the graft segment was sacrificed and the remaining portion placed in a perfusion system (225 cc/min) for 1 hour. Graft segments, effluents, and seeding suspension were assayed in a beta scintillation counter. The percentage of cells that attached pre- and postperfusion were determined, as well as the retrieval of tritium from the system. Initially, 71% of seeded cells attached to grafts coated with fibronectin, with significantly less (60%) remaining attached after perfusion. Only 10% of cells initially attached to uncoated grafts, with 4% retained postperfusion. Retrieval of tritium averaged 102 +/- 10% for all experiments. This system determines both pre- and postperfusion attachment of human endothelial cells to vascular grafts following manipulation of numerous variables, including graft material, substrate, incubation time, and seeding density. An optimal seeding protocol for human trials can thus be determined

  4. Graft type for femoro-popliteal bypass surgery.

    Science.gov (United States)

    Ambler, Graeme K; Twine, Christopher P

    2018-02-11

    Femoro-popliteal bypass is implemented to save limbs that might otherwise require amputation, in patients with ischaemic rest pain or tissue loss; and to improve walking distance in patients with severe life-limiting claudication. Contemporary practice involves grafts using autologous vein, polytetrafluoroethylene (PTFE) or Dacron as a bypass conduit. This is the second update of a Cochrane review first published in 1999 and last updated in 2010. To assess the effects of bypass graft type in the treatment of stenosis or occlusion of the femoro-popliteal arterial segment, for above- and below-knee femoro-popliteal bypass grafts. For this update, the Cochrane Vascular Information Specialist searched the Vascular Specialised Register (13 March 2017) and CENTRAL (2017, Issue 2). Trial registries were also searched. We included randomised trials comparing at least two different types of femoro-popliteal grafts for arterial reconstruction in patients with femoro-popliteal ischaemia. Randomised controlled trials comparing bypass grafting to angioplasty or to other interventions were not included. Both review authors (GKA and CPT) independently screened studies, extracted data, assessed trials for risk of bias and graded the quality of the evidence using GRADE criteria. We included nineteen randomised controlled trials, with a total of 3123 patients (2547 above-knee, 576 below-knee bypass surgery). In total, nine graft types were compared (autologous vein, polytetrafluoroethylene (PTFE) with and without vein cuff, human umbilical vein (HUV), polyurethane (PUR), Dacron and heparin bonded Dacron (HBD); FUSION BIOLINE and Dacron with external support). Studies differed in which graft types they compared and follow-up ranged from six months to 10 years.Above-knee bypassFor above-knee bypass, there was moderate-quality evidence that autologous vein grafts improve primary patency compared to prosthetic grafts by 60 months (Peto odds ratio (OR) 0.47, 95% confidence interval (CI

  5. Design of 3D scaffolds for tissue engineering testing a tough polylactide-based graft copolymer

    International Nuclear Information System (INIS)

    Dorati, R.; Colonna, C.; Tomasi, C.; Genta, I.; Bruni, G.; Conti, B.

    2014-01-01

    The aim of this research was to investigate a tough polymer to develop 3D scaffolds and 2D films for tissue engineering applications, in particular to repair urethral strictures or defects. The polymer tested was a graft copolymer of polylactic acid (PLA) synthesized with the rationale to improve the toughness of the related PLA homopolymer. The LMP-3055 graft copolymer (in bulk) demonstrated to have negligible cytotoxicity (bioavailability > 85%, MTT test). Moreover, the LMP-3055 sterilized through gamma rays resulted to be cytocompatible and non-toxic, and it has a positive effect on cell biofunctionality, promoting the cell growth. 3D scaffolds and 2D film were prepared using different LMP-3055 polymer concentrations (7.5, 10, 12.5 and 15%, w/v), and the effect of polymer concentration on pore size, porosity and interconnectivity of the 3D scaffolds and 2D film was investigated. 3D scaffolds got better results for fulfilling structural and biofunctional requirements: porosity, pore size and interconnectivity, cell attachment and proliferation. 3D scaffolds obtained with 10 and 12.5% polymer solutions (3D-2 and 3D-3, respectively) were identified as the most suitable construct for the cell attachment and proliferation presenting pore size ranged between 100 and 400 μm, high porosity (77–78%) and well interconnected pores. In vitro cell studies demonstrated that all the selected scaffolds were able to support the cell proliferation, the cell attachment and growth resulting to their dependency on the polymer concentration and structural features. The degradation test revealed that the degradation of polymer matrix (ΔMw) and water uptake of 3D scaffolds exceed those of 2D film and raw polymer (used as control reference), while the mass loss of samples (3D scaffold and 2D film) resulted to be controlled, they showed good stability and capacity to maintain the physical integrity during the incubation time. - Highlights: • Tough PLA graft copolymer was proposed

  6. Design of 3D scaffolds for tissue engineering testing a tough polylactide-based graft copolymer

    Energy Technology Data Exchange (ETDEWEB)

    Dorati, R., E-mail: rossella.dorati@unipv.it [Department of Drug Sciences, University of Pavia, V.le Taramelli 12, 27100 Pavia (Italy); Center for Tissue Engineering (CIT), University of Pavia, Via Ferrata 1, 27100 Pavia (Italy); Colonna, C. [Department of Drug Sciences, University of Pavia, V.le Taramelli 12, 27100 Pavia (Italy); Center for Tissue Engineering (CIT), University of Pavia, Via Ferrata 1, 27100 Pavia (Italy); Tomasi, C. [C.S.G.I., Department of Chemistry, Division of Physical Chemistry, University of Pavia, V.le Taramelli 16 I, 27100 Pavia (Italy); Genta, I. [Department of Drug Sciences, University of Pavia, V.le Taramelli 12, 27100 Pavia (Italy); Center for Tissue Engineering (CIT), University of Pavia, Via Ferrata 1, 27100 Pavia (Italy); Bruni, G. [C.S.G.I., Department of Chemistry, Division of Physical Chemistry, University of Pavia, V.le Taramelli 16 I, 27100 Pavia (Italy); Conti, B. [Department of Drug Sciences, University of Pavia, V.le Taramelli 12, 27100 Pavia (Italy); Center for Tissue Engineering (CIT), University of Pavia, Via Ferrata 1, 27100 Pavia (Italy)

    2014-01-01

    The aim of this research was to investigate a tough polymer to develop 3D scaffolds and 2D films for tissue engineering applications, in particular to repair urethral strictures or defects. The polymer tested was a graft copolymer of polylactic acid (PLA) synthesized with the rationale to improve the toughness of the related PLA homopolymer. The LMP-3055 graft copolymer (in bulk) demonstrated to have negligible cytotoxicity (bioavailability > 85%, MTT test). Moreover, the LMP-3055 sterilized through gamma rays resulted to be cytocompatible and non-toxic, and it has a positive effect on cell biofunctionality, promoting the cell growth. 3D scaffolds and 2D film were prepared using different LMP-3055 polymer concentrations (7.5, 10, 12.5 and 15%, w/v), and the effect of polymer concentration on pore size, porosity and interconnectivity of the 3D scaffolds and 2D film was investigated. 3D scaffolds got better results for fulfilling structural and biofunctional requirements: porosity, pore size and interconnectivity, cell attachment and proliferation. 3D scaffolds obtained with 10 and 12.5% polymer solutions (3D-2 and 3D-3, respectively) were identified as the most suitable construct for the cell attachment and proliferation presenting pore size ranged between 100 and 400 μm, high porosity (77–78%) and well interconnected pores. In vitro cell studies demonstrated that all the selected scaffolds were able to support the cell proliferation, the cell attachment and growth resulting to their dependency on the polymer concentration and structural features. The degradation test revealed that the degradation of polymer matrix (ΔMw) and water uptake of 3D scaffolds exceed those of 2D film and raw polymer (used as control reference), while the mass loss of samples (3D scaffold and 2D film) resulted to be controlled, they showed good stability and capacity to maintain the physical integrity during the incubation time. - Highlights: • Tough PLA graft copolymer was proposed

  7. Triple-Layer Vascular Grafts Fabricated by Combined E-Jet 3D Printing and Electrospinning.

    Science.gov (United States)

    Huang, Ruiying; Gao, Xiangkai; Wang, Jian; Chen, Haoxiang; Tong, Chunyi; Tan, Yongjun; Tan, Zhikai

    2018-05-29

    Small-diameter tissue-engineered vascular grafts are urgently needed for clinic arterial substitute. To simulate the structures and functions of natural blood vessels, we designed a novel triple-layer poly(ε-caprolactone) (PCL) fibrous vascular graft by combining E-jet 3D printing and electrospinning techniques. The resultant vascular graft consisted of an interior layer comprising 3D-printed highly aligned strong fibers, a middle layer made by electrospun densely fibers, and an exterior structure composed of mixed fibers fabricated by co-electrospraying. The biocompatible triple-layer graft was used for in vivo implantation, and results demonstrated that the longitudinally-aligned fibers within the lumen of the graft could enhance the proliferation and migration of endothelial cells, while maintained good mechanical properties. The exterior layer provided a pathway that encouraged cells to migrate into the scaffold after implantation. This experimental graft overcame the limitations of conventionally electrospun vascular grafts of inadequate porosity and lowly cell penetration. The unique structure of the triple-layer vascular graft promoted cell growth and infiltration in vivo, thus provided an encouraging substitute for in situ tissue engineering.

  8. The Safety and Efficacy of Cell-Assisted Fat Grafting to Traditional Fat Grafting in the Anterior Mid-Face: An Indirect Assessment by 3D Imaging.

    Science.gov (United States)

    Sasaki, Gordon H

    2015-12-01

    Numerous methodologies and algorithms have been suggested to enhance fat graft survival, including the usage of stromal vascular fraction (SVF) and platelet-rich plasma (PRP), but no long-term studies are available. This single-center prospective, case-controlled study investigated the safety and efficacy of combining a modified Baker-designed lateral SMASectomy or plication face lift with simultaneous anterior mid-face grafting into site-specific compartments by (1) conventional Coleman's technique or (2) Yoshimura's cell-assisted lipografting technique. On the voluntary principle, candidates selected one of four techniques for volumization of their mid-face: conventional fat grafting; PRP-assisted fat grafting; SVF-assisted fat grafting; and PRP/SVF- assisted fat grafting. For comparison data, comparable fat volumes, SVF volumes and nucleated cells, and PRP volumes and platelet concentrations were injected into each designated group. Indirect volume retentions were determined by standardized Vectra 3D analyses up to 1 year. PRP, SVF, and PRP/SVF cell supplementation of processed fat resulted in statistically significant percent mean graft retention over their baseline control at 12 months (p facial aesthetic surgery. With refinements in the entire grafting process and the potential benefits of autologous cell approaches with SVF and PRP, future evidence-based controlled studies under regulatory approval may improve graft survival in a safe and effective manner. This journal requires that authors assign a level of evidence to each article. For a full description of these Evidence-Based Medicine ratings, please refer to the Table of Contents or the online Instructions to Authors www.springer.com/00266.

  9. Coronary Arteries Segmentation Based on the 3D Discrete Wavelet Transform and 3D Neutrosophic Transform

    OpenAIRE

    Shuo-Tsung Chen; Tzung-Dau Wang; Wen-Jeng Lee; Tsai-Wei Huang; Pei-Kai Hung; Cheng-Yu Wei; Chung-Ming Chen; Woon-Man Kung

    2015-01-01

    Purpose. Most applications in the field of medical image processing require precise estimation. To improve the accuracy of segmentation, this study aimed to propose a novel segmentation method for coronary arteries to allow for the automatic and accurate detection of coronary pathologies. Methods. The proposed segmentation method included 2 parts. First, 3D region growing was applied to give the initial segmentation of coronary arteries. Next, the location of vessel information, HHH subband c...

  10. Fast CSF MRI for brain segmentation; Cross-validation by comparison with 3D T1-based brain segmentation methods.

    Science.gov (United States)

    van der Kleij, Lisa A; de Bresser, Jeroen; Hendrikse, Jeroen; Siero, Jeroen C W; Petersen, Esben T; De Vis, Jill B

    2018-01-01

    In previous work we have developed a fast sequence that focusses on cerebrospinal fluid (CSF) based on the long T2 of CSF. By processing the data obtained with this CSF MRI sequence, brain parenchymal volume (BPV) and intracranial volume (ICV) can be automatically obtained. The aim of this study was to assess the precision of the BPV and ICV measurements of the CSF MRI sequence and to validate the CSF MRI sequence by comparison with 3D T1-based brain segmentation methods. Ten healthy volunteers (2 females; median age 28 years) were scanned (3T MRI) twice with repositioning in between. The scan protocol consisted of a low resolution (LR) CSF sequence (0:57min), a high resolution (HR) CSF sequence (3:21min) and a 3D T1-weighted sequence (6:47min). Data of the HR 3D-T1-weighted images were downsampled to obtain LR T1-weighted images (reconstructed imaging time: 1:59 min). Data of the CSF MRI sequences was automatically segmented using in-house software. The 3D T1-weighted images were segmented using FSL (5.0), SPM12 and FreeSurfer (5.3.0). The mean absolute differences for BPV and ICV between the first and second scan for CSF LR (BPV/ICV: 12±9/7±4cc) and CSF HR (5±5/4±2cc) were comparable to FSL HR (9±11/19±23cc), FSL LR (7±4, 6±5cc), FreeSurfer HR (5±3/14±8cc), FreeSurfer LR (9±8, 12±10cc), and SPM HR (5±3/4±7cc), and SPM LR (5±4, 5±3cc). The correlation between the measured volumes of the CSF sequences and that measured by FSL, FreeSurfer and SPM HR and LR was very good (all Pearson's correlation coefficients >0.83, R2 .67-.97). The results from the downsampled data and the high-resolution data were similar. Both CSF MRI sequences have a precision comparable to, and a very good correlation with established 3D T1-based automated segmentations methods for the segmentation of BPV and ICV. However, the short imaging time of the fast CSF MRI sequence is superior to the 3D T1 sequence on which segmentation with established methods is performed.

  11. Therapeutic efficacy of pedicle screw-rod internal fixation after one-stage posterior transforaminal lesion debridement and non-structural bone grafting for tuberculosis of lumbar vertebra

    Directory of Open Access Journals (Sweden)

    Jia-ming LIU

    2015-11-01

    Full Text Available Objective To evaluate the efficacy and safety of pedicle screw-rod internal fixation after one-stage posterior transforaminal lesion debridement and non-structural bone grafting in the treatment of tuberculosis of mono-segmental lumbar vertebra. Methods From January 2010 to April 2013, 21 patients (9 males and 12 females with an average age of 49.1 years with mono-segmental tuberculosis of lumbar vertebra underwent surgery in our hospital were included. Eight patients had neurological deficit. The focus of tuberculosis was located on one side of the vertebral body, and all the patients had obvious signs of bone destruction on CT and MRI. All the patients were given anti-tuberculosis chemotherapy for 2-3 weeks before surgery. The local bone chips and autologous iliac cancellous bone were used as the intervertebral bone graft. Postoperative plain radiographs and CT were obtained to evaluate the fusion rate and degree of lumbar lordosis. The visual analogue scale score (VAS, erythrocyte sedimentation rate (ESR, and C-reactive protein (CRP before and after operation, and at final follow-up date were recorded. Results All the patients were followed up for 25.3±4.2 months. The mean operation time was 157±39 minutes, and the average blood loss was 470±143ml. The fusion rate of the interbody bone graft was 95.2%, with an average fusion period of 6.1±2.5 months. The neurological function was improved by 100%, and no severe complication or neurological injury occured. The preoperative and postoperative lordosis angles of the lumbar spine were 21.4°±5.7° and 33.6°±3.1°, respectively, and it was 31.3°±2.7° at the final follow up. The preoperative and postoperative VAS scores were 7.8±2.6 and 2.4±1.7 respectively, and it was 0.9±0.7 at the final follow up. The ESR and CRP were significantly decreased 3 months after surgery, and they became normal at 6 months. Conclusion Pedicle screw-rod internal fixation after one-stage posterior

  12. Grafting the alar rim: application as anatomical graft.

    Science.gov (United States)

    Gruber, Ronald P; Fox, Paige; Peled, Anne; Belek, Kyle A

    2014-12-01

    Alar rim contour and alar rim grafts have become essential components of rhinoplasty. Ideally, grafts of the nose should be anatomical in shape. So doing might make grafts of the alar rim more robust. The authors considered doing that by applying the graft as a continuous extension of the lateral crus. Twelve patients (two men and 10 women) constituted the study group (seven primary and five secondary cases). Of those, there were five concave rims, two concave rims with rim retraction, two boxy tips, and three cephalically oriented lateral crura. Surgical technique included the following: (1) an open approach was used; (2) a marginal incision that ignored the caudal margin of the lateral crus (the incision went straight posteriorly to a point 5 to 6 mm from the rim margin) was used; (3) a triangular graft was made to cover the exposed vestibular skin; (4) it was secured end to end to the caudal border of the lateral crus; and (5) the poster end was allowed to sit in a small subcutaneous pocket. Follow-up was 11 to 19 months. All 12 patients exhibited good rims as judged by a blinded panel. Rim retraction was not fully corrected in one patient, but no further treatment was required. One patient did require a secondary small rim graft for residual rim concavity. The concept of grafting the alar rim is strongly supported by the authors' results. The modifications the authors applied by designing the graft to be anatomical in shape has been a technical help.

  13. Infolding of fenestrated endovascular stent graft.

    Science.gov (United States)

    Zelt, Jason G E; Jetty, Prasad; Hadziomerovic, Adnan; Nagpal, Sudhir

    2017-09-01

    We report a case of infolding of a fenestrated stent graft involving the visceral vessel segment after a juxtarenal abdominal aorta aneurysm repair. The patient remains free of any significant endoleak, and the aortic sac has shown regression. The patient remains asymptomatic, with no abdominal pain, with normal renal function, and without ischemic limb complications. We hypothesize that significant graft oversizing (20%-30%) with asymmetric engineering of the diameter-reducing ties may have contributed to the infolding. Because of the patient's asymptomatic nature and general medical comorbidities, further intervention was deemed inappropriate as the aneurysmal sac is regressing despite the infolding.

  14. A software tool for automatic classification and segmentation of 2D/3D medical images

    International Nuclear Information System (INIS)

    Strzelecki, Michal; Szczypinski, Piotr; Materka, Andrzej; Klepaczko, Artur

    2013-01-01

    Modern medical diagnosis utilizes techniques of visualization of human internal organs (CT, MRI) or of its metabolism (PET). However, evaluation of acquired images made by human experts is usually subjective and qualitative only. Quantitative analysis of MR data, including tissue classification and segmentation, is necessary to perform e.g. attenuation compensation, motion detection, and correction of partial volume effect in PET images, acquired with PET/MR scanners. This article presents briefly a MaZda software package, which supports 2D and 3D medical image analysis aiming at quantification of image texture. MaZda implements procedures for evaluation, selection and extraction of highly discriminative texture attributes combined with various classification, visualization and segmentation tools. Examples of MaZda application in medical studies are also provided

  15. A software tool for automatic classification and segmentation of 2D/3D medical images

    Energy Technology Data Exchange (ETDEWEB)

    Strzelecki, Michal, E-mail: michal.strzelecki@p.lodz.pl [Institute of Electronics, Technical University of Lodz, Wolczanska 211/215, 90-924 Lodz (Poland); Szczypinski, Piotr; Materka, Andrzej; Klepaczko, Artur [Institute of Electronics, Technical University of Lodz, Wolczanska 211/215, 90-924 Lodz (Poland)

    2013-02-21

    Modern medical diagnosis utilizes techniques of visualization of human internal organs (CT, MRI) or of its metabolism (PET). However, evaluation of acquired images made by human experts is usually subjective and qualitative only. Quantitative analysis of MR data, including tissue classification and segmentation, is necessary to perform e.g. attenuation compensation, motion detection, and correction of partial volume effect in PET images, acquired with PET/MR scanners. This article presents briefly a MaZda software package, which supports 2D and 3D medical image analysis aiming at quantification of image texture. MaZda implements procedures for evaluation, selection and extraction of highly discriminative texture attributes combined with various classification, visualization and segmentation tools. Examples of MaZda application in medical studies are also provided.

  16. Sci-Thur AM: YIS – 03: Combining sagittally-reconstructed 3D and live-2D ultrasound for high-dose-rate prostate brachytherapy needle segmentation

    Energy Technology Data Exchange (ETDEWEB)

    Hrinivich, Thomas; Hoover, Douglas; Surry, Kathleen; Edirisinghe, Chandima; D’Souza, David; Fenster, Aaron; Wong, Eugene [University of Western Ontario, London Regional Cancer Program/LHSC, London Regional Cancer Program/LHSC, Robarts Research Institute, London Regional Cancer Program/LHSC, Robarts Research Institute, University of Western Ontario (Canada)

    2016-08-15

    Ultrasound-guided high-dose-rate prostate brachytherapy (HDR-BT) needle segmentation is performed clinically using live-2D sagittal images. Organ segmentation is then performed using axial images, introducing a source of geometric uncertainty. Sagittally-reconstructed 3D (SR3D) ultrasound enables both needle and organ segmentation, but suffers from shadow artifacts. We present a needle segmentation technique augmenting SR3D with live-2D sagittal images using mechanical probe tracking to mitigate image artifacts and compare it to the clinical standard. Seven prostate cancer patients underwent TRUS-guided HDR-BT during which the clinical and proposed segmentation techniques were completed in parallel using dual ultrasound video outputs. Calibrated needle end-length measurements were used to calculate insertion depth errors (IDEs), and the dosimetric impact of IDEs was evaluated by perturbing clinical treatment plan source positions. The proposed technique provided smaller IDEs than the clinical approach, with mean±SD of −0.3±2.2 mm and −0.5±3.7mm respectively. The proposed and clinical techniques resulted in 84% and 43% of needles with IDEs within ±3mm, and IDE ranges across all needles of [−7.7mm, 5.9mm] and [−9.3mm, 7.7mm] respectively. The proposed and clinical IDEs lead to mean±SD changes in the volume of the prostate receiving the prescription dose of −0.6±0.9% and −2.0±5.3% respectively. The proposed technique provides improved HDR-BT needle segmentation accuracy over the clinical technique leading to decreased dosimetric uncertainty by eliminating the axial-to-sagittal registration, and mitigates the effect of shadow artifacts by incorporating mechanically registered live-2D sagittal images.

  17. Toward transparent nanocomposites based on polystyrene matrix and PMMA-grafted CeO2 nanoparticles.

    Science.gov (United States)

    Parlak, Onur; Demir, Mustafa M

    2011-11-01

    The association of transparent polymer and nanosized pigment particles offers attractive optical materials for various potential and existing applications. However, the particles embedded into polymers scatter light due to refractive index (RI) mismatch and reduce transparency of the resulting composite material. In this study, optical composites based on polystyrene (PS) matrix and poly(methyl methacrylate) (PMMA)-grafted CeO(2) hybrid particles were prepared. CeO(2) nanoparticles with an average diameter of 18 ± 8 nm were precipitated by treating Ce(NO(3))·6H(2)O with urea in the presence of a polymerizable surfactant, 3-methacyloxypropyltrimethoxy silane. PMMA chains were grafted on the surface of the nanoparticles upon free radical in situ solution polymerization. While blending of unmodified CeO(2) particles with PS resulted in opaque films, the transparency of the composite films was remarkably enhanced when prepared by PMMA-grafted CeO(2) hybrid particles, particularly those having a PMMA thickness of 9 nm. The improvement in transparency is presumably due to the reduction in RI mismatch between CeO(2) particles and the PS matrix when using PMMA chains at the interface.

  18. Aortic Graft Infection Secondary to Iatrogenic Transcolonic Graft Malposition.

    Science.gov (United States)

    Blank, Jacqueline J; Rothstein, Abby E; Lee, Cheong Jun; Malinowski, Michael J; Lewis, Brian D; Ridolfi, Timothy J; Otterson, Mary F

    2018-01-01

    Aortic graft infections are a rare but devastating complication of aortic revascularization. Often infections occur due to contamination at the time of surgery. Iatrogenic misplacement of the limbs of an aortobifemoral graft is exceedingly rare, and principles of evaluation and treatment are not well defined. We report 2 cases of aortobifemoral bypass graft malposition through the colon. Case 1 is a 54-year-old male who underwent aortobifemoral bypass grafting for acute limb ischemia. He had previously undergone a partial sigmoid colectomy for diverticulitis. Approximately 6 months after vascular surgery, he presented with an occult graft infection. Preoperative imaging and intraoperative findings were consistent with graft placement through the sigmoid colon. Case 2 is a 60-year-old male who underwent aortobifemoral bypass grafting due to a nonhealing wound after toe amputation. His postoperative course was complicated by pneumonia, bacteremia thought to be secondary to the pneumonia, general malaise, and persistent fevers. Approximately 10 weeks after the vascular surgery, he presented with imaging and intraoperative findings of graft malposition through the cecum. Aortic graft infection is usually caused by surgical contamination and presents as an indolent infection. Case 1 presented as such; Case 2 presented more acutely. Both grafts were iatrogenically misplaced through the colon at the index operation. The patients underwent extra-anatomic bypass and graft explantation and subsequently recovered.

  19. Extended 3D Line Segments from RGB-D Data for Pose Estimation

    DEFF Research Database (Denmark)

    Buch, Anders Glent; Jessen, Jeppe Barsøe; Kraft, Dirk

    2013-01-01

    We propose a method for the extraction of complete and rich symbolic line segments in 3D based on RGB-D data. Edges are detected by combining cues from the RGB image and the aligned depth map. 3D line segments are then reconstructed by back-projecting 2D line segments and intersecting this with l...... this with local surface patches computed from the 3D point cloud. Different edge types are classified using the new enriched representation and the potential of this representation for the task of pose estimation is demonstrated....

  20. 3D TEM reconstruction and segmentation process of laminar bio-nanocomposites

    International Nuclear Information System (INIS)

    Iturrondobeitia, M.; Okariz, A.; Fernandez-Martinez, R.; Jimbert, P.; Guraya, T.; Ibarretxe, J.

    2015-01-01

    The microstructure of laminar bio-nanocomposites (Poly (lactic acid)(PLA)/clay) depends on the amount of clay platelet opening after integration with the polymer matrix and determines the final properties of the material. Transmission electron microscopy (TEM) technique is the only one that can provide a direct observation of the layer dispersion and the degree of exfoliation. However, the orientation of the clay platelets, which affects the final properties, is practically immeasurable from a single 2D TEM image. This issue can be overcome using transmission electron tomography (ET), a technique that allows the complete 3D characterization of the structure, including the measurement of the orientation of clay platelets, their morphology and their 3D distribution. ET involves a 3D reconstruction of the study volume and a subsequent segmentation of the study object. Currently, accurate segmentation is performed manually, which is inefficient and tedious. The aim of this work is to propose an objective/automated segmentation methodology process of a 3D TEM tomography reconstruction. In this method the segmentation threshold is optimized by minimizing the variation of the dimensions of the segmented objects and matching the segmented V clay (%) and the actual one. The method is first validated using a fictitious set of objects, and then applied on a nanocomposite

  1. PTFE Graft as a "Bridge" to Communicating Veins Maturation in the Treatment of an Intrahepatic Cholangiocarcinoma Involving the 3 Hepatic Veins. The Minor-but-Complex Liver Resection.

    Science.gov (United States)

    Urbani, Lucio; Balestri, Riccardo; Sidoti, Francesco; Bernardini, Juri Riccardo; Arces, Francesco; Licitra, Gabriella; Leoni, Chiara; Forfori, Francesco; Colombatto, Piero; Boraschi, Piero; Castagna, Maura; Buccianti, Piero

    2016-12-01

    Parenchyma-sparing liver surgery allows resecting hepatic veins (HV) at the hepatocaval confluence with minor (PTFE graft can be used as a bridge to communicating-veins maturation to ensure the correct outflow of the spared liver. We present a video of an intrahepatic cholangiocarcinoma (IC) involving the three HV at the hepatocaval confluence treated with this approach. In a 50-year old obese (BMI 44.8) male a 6-cm IC involving the hepatocaval confluence was identified during the follow-up for a kidney malignancy. At the preoperative CT scan the left HV was not detectable, the middle HV was incorporated within the tumor, and right HV had a 3-cm contact with the tumor. No communicating veins were evident at preoperative imaging. After a J-shape thoracophrenolaparotomy, the resection of segments II-III-IVa was partially extended to segment VIII-VII and I. The right HV was detached from the tumor, and the middle HV was reconstructed with a 7-mm ringed-armed PTFE graft anastomosed to V8. Surgery lasted 20 h and 55 min with an estimated blood loss of 3500 ml, but the postoperative course was uneventful and the patient was discharged on the 14th postoperative day. One month later the CT scan showed a patent PTFE graft with the maturation of communicating-veins. One year later a complete thrombosis of the PTFE graft was observed with normal liver perfusion and function, and the patient was disease-free. PTFE-based parenchyma-sparing liver resection is a new tool to treat tumors located at the hepatocaval confluence exploiting the maturation of intrahepatic communicating-veins between main HV.

  2. Penile Inversion Vaginoplasty with or without Additional Full-Thickness Skin Graft: To Graft or Not to Graft?

    Science.gov (United States)

    Buncamper, Marlon E; van der Sluis, Wouter B; de Vries, Max; Witte, Birgit I; Bouman, Mark-Bram; Mullender, Margriet G

    2017-03-01

    Penile inversion vaginoplasty is considered to be the gold standard for gender reassignment surgery in transgender women. The use of additional full-thickness skin graft as neovaginal lining is controversial. Some believe that having extra penile skin for the vulva gives better aesthetic results. Others believe that it gives inferior functional results because of insensitivity and skin graft contraction. Transgender women undergoing penile inversion vaginoplasty were studied prospectively. The option to add full-thickness skin graft is offered in patients where the penile skin length lies between 7 and 12 cm. Neovaginal depth was measured at surgery and during follow-up (3, 13, 26, and 52 weeks postoperatively). Satisfaction with the aesthetic result, neovaginal depth, and dilation regimen during follow-up were recorded. Satisfaction, sexual function, and genital self-image were assessed using questionnaires. A total of 100 patients were included (32 with and 68 without additional full-thickness skin graft). Patient-reported aesthetic outcome, overall satisfaction with the neovagina, sexual function, and genital self-image were not significantly associated with surgical technique. The mean intraoperative neovaginal depth was 13.8 ± 1.4 cm. After 1 year, this was 11.5 ± 2.5 cm. The largest decline (-15 percent) in depth is observed in the first 3 postoperative weeks (p skin graft use, in penile inversion vaginoplasty. The additional use of full-thickness skin graft does not influence neovaginal shrinkage, nor does it affect the patient- and physician-reported aesthetic or functional outcome. Therapeutic, IV.

  3. Feasibility of fabricating personalized 3D-printed bone grafts guided by high-resolution imaging

    Science.gov (United States)

    Hong, Abigail L.; Newman, Benjamin T.; Khalid, Arbab; Teter, Olivia M.; Kobe, Elizabeth A.; Shukurova, Malika; Shinde, Rohit; Sipzner, Daniel; Pignolo, Robert J.; Udupa, Jayaram K.; Rajapakse, Chamith S.

    2017-03-01

    Current methods of bone graft treatment for critical size bone defects can give way to several clinical complications such as limited available bone for autografts, non-matching bone structure, lack of strength which can compromise a patient's skeletal system, and sterilization processes that can prevent osteogenesis in the case of allografts. We intend to overcome these disadvantages by generating a patient-specific 3D printed bone graft guided by high-resolution medical imaging. Our synthetic model allows us to customize the graft for the patients' macro- and microstructure and correct any structural deficiencies in the re-meshing process. These 3D-printed models can presumptively serve as the scaffolding for human mesenchymal stem cell (hMSC) engraftment in order to facilitate bone growth. We performed highresolution CT imaging of a cadaveric human proximal femur at 0.030-mm isotropic voxels. We used these images to generate a 3D computer model that mimics bone geometry from micro to macro scale represented by STereoLithography (STL) format. These models were then reformatted to a format that can be interpreted by the 3D printer. To assess how much of the microstructure was replicated, 3D-printed models were re-imaged using micro-CT at 0.025-mm isotropic voxels and compared to original high-resolution CT images used to generate the 3D model in 32 sub-regions. We found a strong correlation between 3D-printed bone volume and volume of bone in the original images used for 3D printing (R2 = 0.97). We expect to further refine our approach with additional testing to create a viable synthetic bone graft with clinical functionality.

  4. Dual optimization based prostate zonal segmentation in 3D MR images.

    Science.gov (United States)

    Qiu, Wu; Yuan, Jing; Ukwatta, Eranga; Sun, Yue; Rajchl, Martin; Fenster, Aaron

    2014-05-01

    Efficient and accurate segmentation of the prostate and two of its clinically meaningful sub-regions: the central gland (CG) and peripheral zone (PZ), from 3D MR images, is of great interest in image-guided prostate interventions and diagnosis of prostate cancer. In this work, a novel multi-region segmentation approach is proposed to simultaneously segment the prostate and its two major sub-regions from only a single 3D T2-weighted (T2w) MR image, which makes use of the prior spatial region consistency and incorporates a customized prostate appearance model into the segmentation task. The formulated challenging combinatorial optimization problem is solved by means of convex relaxation, for which a novel spatially continuous max-flow model is introduced as the dual optimization formulation to the studied convex relaxed optimization problem with region consistency constraints. The proposed continuous max-flow model derives an efficient duality-based algorithm that enjoys numerical advantages and can be easily implemented on GPUs. The proposed approach was validated using 18 3D prostate T2w MR images with a body-coil and 25 images with an endo-rectal coil. Experimental results demonstrate that the proposed method is capable of efficiently and accurately extracting both the prostate zones: CG and PZ, and the whole prostate gland from the input 3D prostate MR images, with a mean Dice similarity coefficient (DSC) of 89.3±3.2% for the whole gland (WG), 82.2±3.0% for the CG, and 69.1±6.9% for the PZ in 3D body-coil MR images; 89.2±3.3% for the WG, 83.0±2.4% for the CG, and 70.0±6.5% for the PZ in 3D endo-rectal coil MR images. In addition, the experiments of intra- and inter-observer variability introduced by user initialization indicate a good reproducibility of the proposed approach in terms of volume difference (VD) and coefficient-of-variation (CV) of DSC. Copyright © 2014 Elsevier B.V. All rights reserved.

  5. Sulfonate-grafted porous polymer networks for preferential CO(2) adsorption at low pressure

    NARCIS (Netherlands)

    Lu, W.; Yuan, D.; Sculley, J.; Zhao, D.; Krishna, R.; Zhou, H.-C.

    2011-01-01

    A porous polymer network (PPN) grafted with sulfonic acid (PPN-6-SO3H) and its lithium salt (PPN-6-SO3Li) exhibit significant increases in isosteric heats of CO2 adsorption and CO2-uptake capacities. IAST calculations using single-component-isotherm data and a 15/85 CO2/N2 ratio at 295 K and 1 bar

  6. In-situ infrared study of CO{sub 2} adsorption on SBA-15 grafted with {gamma}-(aminopropyl)triethoxysilane

    Energy Technology Data Exchange (ETDEWEB)

    Alex C.C. Chang; Steven S.C. Chuang; McMahan Gray; Yee Soong [University of Akron, Akron, OH (United States). Chemical Engineering Department

    2003-04-01

    CO{sub 2} adsorption/desorption on SBA-15 grafted with {gamma}-(aminopropyl)triethoxysilane (APTS) has been studied by infrared spectroscopy coupled with temperature-programmed desorption. SBA-15, a mesoporous silica material with a uniform pore size of 21 nm and a surface area of 200-230 m{sup 2}/g, provides an OH functional group for grafting of {gamma}-(aminopropyl)triethoxysilane. The amine-grafted SBA-15 adsorbed CO{sub 2} as carbonates and bicarbonates with a total capacity of 200-400 {mu}mol/g. The heat of CO{sub 2} desorption was determined to be 3.2-4.5 kJ/mol in the presence of H{sub 2}O and 6.6-11.0 kJ/mol in the absence of H{sub 2}O during temperature-programmed desorption. Repeated CO{sub 2} adsorption/desorption CO{sub 2} cycles shifted the desorption peak temperature downward and decreased the heat of CO{sub 2} adsorption. 22 refs., 9 figs., 3 tabs.

  7. Arterial grafts balance survival between incomplete and complete revascularization: a series of 1000 consecutive coronary artery bypass graft patients with 98% arterial grafts.

    Science.gov (United States)

    Kieser, Teresa M; Curran, Helen J; Rose, M Sarah; Norris, Colleen M; Graham, Michelle M

    2014-01-01

    Coronary artery bypass grafting (CABG) with incomplete revascularization (ICR) is thought to decrease survival. We studied the survival of patients with ICR undergoing total arterial grafting. In a consecutive series of all-comer 1000 patients with isolated CABG, operative and midterm survival were assessed for patients undergoing complete versus ICR, with odds ratios and hazard ratios, adjusted for European System for Cardiac Operative Risk Evaluation category, CABG urgency, age, and comorbidities. In this series of 1000 patients with 98% arterial grafts (2922 arterial, 59 vein grafts), 73% of patients with multivessel disease received bilateral internal mammary artery grafts. ICR occurred in 140 patients (14%). Operative mortality was 3.8% overall, 8.6% for patients with ICR, and 3.2% for patients with complete revascularization (P = .008). For operative mortality using multivariable logistic regression, after controlling for European System for Cardiac Operative Risk Evaluation category (P System for Cardiac Operative Risk Evaluation category (P reserved.

  8. 3D prostate TRUS segmentation using globally optimized volume-preserving prior.

    Science.gov (United States)

    Qiu, Wu; Rajchl, Martin; Guo, Fumin; Sun, Yue; Ukwatta, Eranga; Fenster, Aaron; Yuan, Jing

    2014-01-01

    An efficient and accurate segmentation of 3D transrectal ultrasound (TRUS) images plays an important role in the planning and treatment of the practical 3D TRUS guided prostate biopsy. However, a meaningful segmentation of 3D TRUS images tends to suffer from US speckles, shadowing and missing edges etc, which make it a challenging task to delineate the correct prostate boundaries. In this paper, we propose a novel convex optimization based approach to extracting the prostate surface from the given 3D TRUS image, while preserving a new global volume-size prior. We, especially, study the proposed combinatorial optimization problem by convex relaxation and introduce its dual continuous max-flow formulation with the new bounded flow conservation constraint, which results in an efficient numerical solver implemented on GPUs. Experimental results using 12 patient 3D TRUS images show that the proposed approach while preserving the volume-size prior yielded a mean DSC of 89.5% +/- 2.4%, a MAD of 1.4 +/- 0.6 mm, a MAXD of 5.2 +/- 3.2 mm, and a VD of 7.5% +/- 6.2% in - 1 minute, deomonstrating the advantages of both accuracy and efficiency. In addition, the low standard deviation of the segmentation accuracy shows a good reliability of the proposed approach.

  9. UV-Induced [2+2] Grafting-To Reactions for Polymer Modification of Cellulose.

    Science.gov (United States)

    Conradi, Matthias; Ramakers, Gijs; Junkers, Thomas

    2016-01-01

    Benzaldehyde-functional cellulose paper sheets have been synthesized via tosylation of cellulose (Whatman No 5) followed by addition of p-hydroxy benzaldehyde. Via UV-induced Paterno-Büchi [2+2] cycloaddition reactions, these aldehyde functional surfaces are grafted with triallylcyanurate, trimethylolpropane allyl ether, and vinyl chloroacetate. In the following, allyl-functional polymers (poly(butyl acrylate), pBA, Mn = 6990 g mol(-1) , Đ = 1.12 and poly(N-isopropyl acrylamide), pNIPAAm, Mn = 9500 g mol(-1) , Đ = 1.16) synthesized via reversible addition fragmentation chain transfer polymerization are conjugated to the celloluse surface in a UV-induced grafting-to approach. With pBA, hydrophobic cellulose sheets are obtained (water contact angle 116°), while grafting of pNIPAAm allows for generation of "smart" surfaces, which are hydrophilic at room temperature, but that become hydrophobic when heated above the characteristic lower critical solution temperature (93° contact angle). The Paterno-Büchi reaction has been shown to be a versatile synthetic tool that also performs well in grafting-to approaches whereby its overall performance seems to be close to that of radical thiol-ene reactions. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  10. Comb-like temperature-responsive polyhydroxyalkanoate-graft-poly(2-dimethylamino-ethylmethacrylate) for controllable protein adsorption

    DEFF Research Database (Denmark)

    Yao, Hui; Wei, Daixu; Che, Xuemei

    2016-01-01

    %. Graft copolymer PHA-g-PDMAEMA showed enhanced thermal stability, biocompatibility and controllable hydrophilicity compared with non-grafted P(3HDD-co-3H9D). The grafted material presented an obvious tendency of increasing protein adsorptions over the lower critical solution temperature (LCST 47.5 °C...... controllable protein adsorption for biomedical usages....

  11. Modification of polyetherurethane for biomedical application by radiation induced grafting. II. Water sorption, surface properties, and protein adsorption of grafted films

    International Nuclear Information System (INIS)

    Jansen, B.; Ellinghorst, G.

    1984-01-01

    A series of polyetherurethane films grafted by means of gamma radiation with hydrophilic or reactive monomers (2-hydroxyethyl methacrylate, 2,3-epoxypropyl methacrylate, 2,3-dihydroxypropyl methacrylate, and acrylamide) and partially chemically modified were subjected to various physico-chemical investigation methods involving water sorption, contact angle, and protein adsorption measurements. From contact angle data the interfacial free energy gamma sw between grafted films and water was calculated. It was found that the water uptake of grafted films increases with grafting yield or, in the case of grafted and afterwards chemically modified films, with reaction yield; the diffusion coefficient of water in the modified films also increases with grafting yield. Contact angle studies revealed all grafted films to have surfaces more hydrophilic than the ungrafted trunk polymer. The degree of hydrophilicity--especially of HEMA-grafted films--strongly depends on grafting conditions. For some grafted samples with high surface hydrophilicity very low interfacial free energies approaching zero were measured. The study of the competitive adsorption of bovine serum albumin, gamma-globulin, and fibrinogen from a synthetic protein solution onto modified films showed that the adsorption of albumin increases markedly with increasing grafting yields, whereas the fibrinogen and gamma-globulin adsorption only slightly increases. A correlation between interfacial free energy and protein adsorption in the sense of the minimum interfacial free energy hypothesis was found only for samples with grafting yields below 5%. At higher grafting yields the increased surface area complicates the analysis

  12. Segmental maxillary distraction with a novel device for closure of a wide alveolar cleft.

    Science.gov (United States)

    Bousdras, Vasilios A; Liyanage, Chandra; Mars, Michael; Ayliffe, Peter R

    2014-01-01

    Treatment of a wide alveolar cleft with initial application of segmental distraction osteogenesis is reported, in order to minimise cleft size prior to secondary alveolar bone grafting. The lesser maxillary segment was mobilised with osteotomy at Le Fort I level and, a novel distractor, facilitated horizontal movement of the dental/alveolar segment along the curvature of the maxillary dental arch. Following a latency period of 4 days distraction was applied for 7 days at a rate of 0.5 mm twice daily. Radiographic, ultrasonographic and clinical assessment revealed new bone and soft tissue formation 8 weeks after completion of the distraction phase. Overall the maxillary segment did move minimising the width of the cleft, which allowed successful closure with a secondary alveolar bone graft.

  13. Evaluation of early coronary graft patency after coronary artery bypass graft surgery using multislice computed tomography angiography

    Directory of Open Access Journals (Sweden)

    Raissi Kamal

    2009-12-01

    Full Text Available Abstract Background Coronary artery bypass graft (CABG surgery is the standard of care in the treatment of advanced coronary artery disease, and its long-term results are affected by the failure of bypass grafts. The aim of the present study was to evaluate the early patency rate in coronary bypass grafts. Methods A total of 107 consecutive patients who underwent CABG were included in this study. Early graft patency was evaluated via computed tomography (CT angiography in the first week after surgery. Results There were a total of 366 grafts, comprised of 250 venous grafts and 116 arterial grafts. Multi-slice CT detected acute graft occlusions in 32 (8.7% of all the grafts, including 26 (10% of the 250 venous grafts and 6 (5% of the 116 arterial grafts. The patency rates obtained were 97.3% for the left internal mammary (IMA grafts, 50% for the radial artery grafts, and 50% for the right IMA grafts. Additionally, 107 (96.4% grafts to the left anterior descending artery (LAD were classified as patent, whereas 1 (30% of the 3 grafts in the left circumflex (LCX region and 1 (50% of the 2 grafts in the right coronary artery (RCA territory were found to be occluded. In the venous category, 8 (13.7% of the 58 grafts to LAD were found to be occluded. In the LCX region, 9 (8.5% of the 106 grafts were classified as occluded, while the remaining 97 (91.5% grafts were patent. The venous grafts to RCA were occluded in 9 (10.4% of the 86 grafts. Amongst the multiple preoperative, intraoperative, and postoperative factors, pump time was significantly longer in the patients with occluded grafts than in those with patent grafts (P = 0.04. Conclusion The IMA grafts had the highest early patency rate amongst the coronary bypass grafts. However, the other arterial grafts were associated with a high rate of acute occlusions.

  14. Current status of grafts and implants in rhinoplasty: Part II. Homologous grafts and allogenic implants.

    Science.gov (United States)

    Sajjadian, Ali; Naghshineh, Nima; Rubinstein, Roee

    2010-03-01

    After reading this article, the participant should be able to: 1. Understand the challenges in restoring volume and structural integrity in rhinoplasty. 2. Identify the appropriate uses of various homologous grafts and allogenic implants in reconstruction, including: (a) freeze-dried acellular allogenic cadaveric dermis grafts, (b) irradiated cartilage grafts, (c) hydroxyapatite mineral matrix, (d) silicone implants, (e) high-density polyethylene implants, (f) polytetrafluoroethylene implants, and (g) injectable filler materials. 3. Identify the advantages and disadvantages of each of these biomaterials. 4. Understand the specific techniques that may aid in the use these grafts or implants. This review specifically addresses the use of homologous grafts and allogenic implants in rhinoplasty. It is important to stress that autologous materials remain the preferred graft material for use in rhinoplasty, owing to their high biocompatibility and low risk of infection and extrusion. However, concerns of donor-site morbidity, graft availability, and graft resorption have motivated the development and use of homologous and allogenic implants.

  15. A COMPARATIVE STUDY OF TYMPANOPLASTY USING SLICED CARTILAGE GRAFT VS. TEMPORALIS FASCIA GRAFT

    Directory of Open Access Journals (Sweden)

    Rahul Ashok Telang

    2018-02-01

    Full Text Available BACKGROUND The objective of the study was to compare the hearing improvement after using sliced cartilage graft with that of temporalis fascia and to compare the graft take-up between the two graft materials. MATERIALS AND METHODS A prospective clinical study including 60 patients with chronic mucosal otitis media, who were selected randomly from the outpatient department, after obtaining their consent were divided into 2 groups of 30 each, and evaluated according the study protocol. Their pre-operative audiometry was recorded and both groups of patients underwent surgery with one of the graft materials- temporalis fascia or sliced tragal cartilage with a thickness of 0.5 mm. All patients were regularly followed up and post-operative audiometry was done at 3 months. The hearing improvement in the form of closure of air-bone-gap and graft take-up was analysed statistically. RESULTS The temporalis fascia graft group had a pre-operative ABG of 22.33 ± 6.24 dB and post-operative ABG of 12.33 ± 4.72 dB with hearing improvement of 10.00 dB. The sliced cartilage graft group had a pre-operative ABG of 20.77 ± 5.75 dB and postoperative ABG of 10.50 ± 4.46 dB with hearing improvement of 10.27 dB. In the temporalis fascia group, 28 (93.3% patients had good graft take-up and in the sliced cartilage group 29 (96.7% had good graft take-up. There was statistically significant hearing improvement in both of our study groups but there was no statistically significant difference between the two groups. There was no statistically significant difference in graft take-up also. CONCLUSION Sliced cartilage graft is a good auto-graft material in tympanoplasty, which can give good hearing improvement and has good graft take-up, which is comparable with that of temporalis fascia.

  16. Surgery for acquired cardiovascular disease: antiseptic treatment of contaminated vein grafts.

    Science.gov (United States)

    Schmidt, F P; Peivandi, A A; Kohnen, W; Jansen, B

    2014-04-01

    Saphenous vein grafts harvested for use as bypass conduits can be contaminated intraoperatively, e.g. by being inadvertently dropped to the floor of the operating room (OR). This study was performed to investigate microorganisms most likely contaminating vein grafts and to assess the possible efficacy of measures to treat potentially contaminated vein grafts antiseptically for further use. In a first step we determined the microbiological flora of the OR using surface cultures and cultures from intentionally dropped vein grafts. Several antiseptic agents (PVP-iodine 10%, octenidinhydrochloride 0.1%, polyhexanide 1%) were evaluated for their in vitro efficacy to disinfect artificially contaminated vein segments. The most promising antiseptic regimen was tested on veins contaminated in a real OR setting. Finally, we tested for possible alterations in mechanical properties of the veins caused by antiseptic treatment. Coagulase-negative staphylococci where the predominant bacteria recovered from the OR with 59.9%. Antiseptic treatment with a combination of octenidine and PVP-iodine resulted in a higher rate of negative cultures than any single agent. Treatment of 50 saphenous vein grafts contaminated in the OR with the combination regimen resulted in only 3 positive cultural results within 7 days. Mechanical tear-stress testing comparing antiseptically treated vein grafts with controls showed no difference in their resistance to tear stress. Antiseptic treatment of contaminated vein grafts was shown to be effective in a high percentage of cases without altering mechanical properties of grafts and may be an option for the surgeon in case of a contamination.

  17. Deformable M-Reps for 3D Medical Image Segmentation

    Science.gov (United States)

    Pizer, Stephen M.; Fletcher, P. Thomas; Joshi, Sarang; Thall, Andrew; Chen, James Z.; Fridman, Yonatan; Fritsch, Daniel S.; Gash, Graham; Glotzer, John M.; Jiroutek, Michael R.; Lu, Conglin; Muller, Keith E.; Tracton, Gregg; Yushkevich, Paul; Chaney, Edward L.

    2013-01-01

    M-reps (formerly called DSLs) are a multiscale medial means for modeling and rendering 3D solid geometry. They are particularly well suited to model anatomic objects and in particular to capture prior geometric information effectively in deformable models segmentation approaches. The representation is based on figural models, which define objects at coarse scale by a hierarchy of figures – each figure generally a slab representing a solid region and its boundary simultaneously. This paper focuses on the use of single figure models to segment objects of relatively simple structure. A single figure is a sheet of medial atoms, which is interpolated from the model formed by a net, i.e., a mesh or chain, of medial atoms (hence the name m-reps), each atom modeling a solid region via not only a position and a width but also a local figural frame giving figural directions and an object angle between opposing, corresponding positions on the boundary implied by the m-rep. The special capability of an m-rep is to provide spatial and orientational correspondence between an object in two different states of deformation. This ability is central to effective measurement of both geometric typicality and geometry to image match, the two terms of the objective function optimized in segmentation by deformable models. The other ability of m-reps central to effective segmentation is their ability to support segmentation at multiple levels of scale, with successively finer precision. Objects modeled by single figures are segmented first by a similarity transform augmented by object elongation, then by adjustment of each medial atom, and finally by displacing a dense sampling of the m-rep implied boundary. While these models and approaches also exist in 2D, we focus on 3D objects. The segmentation of the kidney from CT and the hippocampus from MRI serve as the major examples in this paper. The accuracy of segmentation as compared to manual, slice-by-slice segmentation is reported. PMID

  18. The Effect of Platelet-Rich Plasma on Survival of the Composite Graft and the Proper Time of Injection in a Rabbit Ear Composite Graft Model

    Directory of Open Access Journals (Sweden)

    Hyun Nam Choi

    2014-11-01

    Full Text Available BackgroundAdministration of growth factors has been associated with increased viability of composite grafts greater than 1-cm in diameter. Platelet-rich plasma (PRP contains many of the growth factors studied. In this study, we evaluate the effect of PRP injection on composite graft viability and the proper time for injection.MethodsA total of 24 New Zealand White rabbits were divided into four groups. Autologous PRP was injected into the recipient sites three days before grafting in group 1, on the day of grafting in group 2, and three days after grafting in group 3. Group 4 served as control without PRP administration. Auricular composite grafts of 3-cm diameter were harvested and grafted back into place after being rotated 180 degrees. Median graft viability and microvessel density were evaluated at day 21 of graft via macroscopic photographs and immunofluorescent staining, respectively.ResultsThe median graft survival rate was 97.8% in group 1, 69.2% in group 2, 55.7% in group 3, and 40.8% in the control group. The median vessel counts were 34 (per ×200 HPF in group 1, 24.5 in group 2, 19.5 in group 3, and 10.5 in the control group.ConclusionsThis study demonstrates that PRP administration is associated with increased composite graft viability. All experimental groups showed a significantly higher survival rate and microvessel density, compared with the control group. Pre-administration of PRP was followed by the highest graft survival rate and revascularization. PRP treatments are minimally invasive, fast, easily applicable, and inexpensive, and offer a potential clinical pathway to larger composite grafts.

  19. Neointima development in externally stented saphenous vein grafts

    Directory of Open Access Journals (Sweden)

    Przemysław Węglarz

    2016-11-01

    Full Text Available Introduction : The main limitation of coronary artery bypass grafting (CABG is rapid neointimal hyperplasia leading to graft failure. Aim : To assess plaque formation in saphenous vein grafts (SVG covered by an external Dacron stent in comparison with the classical technique. Material and methods : In the study group vein grafts covered by external stent mesh made of Dacron were implanted. An intravascular ultrasonography (IVUS study was performed in 35 aorto-coronary SVG covered by an external Dacron stent and in 64 normal SVG during the first year after CABG. In each SVG 25 mm of good quality IVUS image, volumes of lumen, plaque (neointima, outer border of the vein graft (external SVG and adventitia were calculated in three time periods: 0–130 days, 130–260 days and 260–390 days. Results : Between the first and second time period, lumen volume (mm3 was reduced from 10.33 ±4.4, to 6.80 ±2.23 in the second period and 5.69 ±1.26 in the third one. This effect was much less marked in normal grafts. The corresponding lumen volume (mm3 was: 10.90 ±3.9, 9.15 ±2.94 and 8.92 ±2.93 in consecutive time periods. Plaque volume (mm3 did not change in control grafts during the course of the study, but it increased very significantly in stented grafts from 0.86 ±1.24 in the first period to 2.70 ±1.58 in the second and 3.29 ±2.66 in the third one. Conclusions : The experimental technique of implanting SVG covered with an external elastic Dacron stent seems to be inferior to traditional ones. This is probably due to the more complicated process of vein implantation and higher micro-injury occurrence during the surgery.

  20. Segmentation, Reconstruction, and Analysis of Blood Thrombus Formation in 3D 2-Photon Microscopy Images

    Directory of Open Access Journals (Sweden)

    Xu Zhiliang

    2010-01-01

    Full Text Available We study the problem of segmenting, reconstructing, and analyzing the structure growth of thrombi (clots in blood vessels in vivo based on 2-photon microscopic image data. First, we develop an algorithm for segmenting clots in 3D microscopic images based on density-based clustering and methods for dealing with imaging artifacts. Next, we apply the union-of-balls (or alpha-shape algorithm to reconstruct the boundary of clots in 3D. Finally, we perform experimental studies and analysis on the reconstructed clots and obtain quantitative data of thrombus growth and structures. We conduct experiments on laser-induced injuries in vessels of two types of mice (the wild type and the type with low levels of coagulation factor VII and analyze and compare the developing clot structures based on their reconstructed clots from image data. The results we obtain are of biomedical significance. Our quantitative analysis of the clot composition leads to better understanding of the thrombus development, and is valuable to the modeling and verification of computational simulation of thrombogenesis.

  1. Corneal Graft Rejection: Incidence and Risk Factors

    Directory of Open Access Journals (Sweden)

    Alireza Baradaran-Rafii

    2008-12-01

    Full Text Available

    PURPOSE: To determine the incidence and risk factors of late corneal graft rejection after penetrating keratoplasty (PKP. METHODS: Records of all patients who had undergone PKP from 2002 to 2004 without immunosuppressive therapy other than systemic steroids and with at least one year of follow up were reviewed. The role of possible risk factors such as demographic factors, other host factors, donor factors, indications for PKP as well as type of rejection were evaluated. RESULTS: During the study period, 295 PKPs were performed on 286 patients (176 male, 110 female. Mean age at the time of keratoplasty was 38±20 (range, 40 days to 90 years and mean follow up period was 20±10 (range 12-43 months. Graft rejection occurred in 94 eyes (31.8% at an average of 7.3±6 months (range, 20 days to 39 months after PKP. The most common type of rejection was endothelial (20.7%. Corneal vascularization, regrafting, anterior synechiae, irritating sutures, active inflammation, additional anterior segment procedures, history of trauma, uncontrolled glaucoma, prior graft rejection, recurrence of herpetic infection and eccentric grafting increased the rate of rejection. Patient age, donor size and bilateral transplantation had no significant influence on graft rejection. CONCLUSION: Significant risk factors for corneal graft rejection include

  2. MDCT angiography with 3D image reconstructions in the evaluation of failing arteriovenous fistulas and grafts in hemodialysis patients

    Energy Technology Data Exchange (ETDEWEB)

    Dimopoulou, Angeliki; Raland, Hans; Magnusson, Anders (Dept. of Radiology, Univ. Hospital, Uppsala (Sweden)), email: angeliki.dimopoulou@akademiska.se; Wikstroem, Bjoern (Dept. of Medical Sciences, Renal Section, Univ. Hospital, Uppsala (Sweden))

    2011-11-15

    Background. Arteriovenous fistulas and grafts are the methods of choice for vascular access in renal failure patients in need of hemodialysis. Their major complication, however, is stenosis, which might lead to thrombosis. Purpose. To demonstrate the usefulness of 16-MDCTA with 3D image reconstructions, in long-term hemodialysis patients with dysfunctional arteriovenous fistulas and grafts (AVF and AVG). Material and Methods. During a 17-month period, 31 patients with dysfunctional AVF and AVG (24 AVF and seven AVG) were examined with MDCTA with 3D image postprocessing. Parameters such as comprehension of the anatomy, quality of contrast enhancement, and pathological vascular changes were measured. DSA was then performed in 24 patients. Results. MDCTA illustrated the anatomy of the AVF/AVG and the entire vascular tree to the heart, in a detailed and comprehensive manner in 93.5% of the evaluated segments, and depicted pathology of AVF/AVG or pathology of the associated vasculature. MDCTA demonstrated a total of 38 significant stenoses in 25 patients. DSA verified 37 stenoses in 24 patients and demonstrated two additional stenoses. MDCTA had thus a sensitivity of 95%. All 24 patients were treated with percutaneous transluminal angioplasty (PTA) with good technical results. Conclusion. MDCTA with 3D reconstructions of dysfunctioning AVFs and AVGs in hemodialysis patients is an accurate and reliable diagnostic method helping customize future intervention

  3. MDCT angiography with 3D image reconstructions in the evaluation of failing arteriovenous fistulas and grafts in hemodialysis patients

    International Nuclear Information System (INIS)

    Dimopoulou, Angeliki; Raland, Hans; Magnusson, Anders; Wikstroem, Bjoern

    2011-01-01

    Background. Arteriovenous fistulas and grafts are the methods of choice for vascular access in renal failure patients in need of hemodialysis. Their major complication, however, is stenosis, which might lead to thrombosis. Purpose. To demonstrate the usefulness of 16-MDCTA with 3D image reconstructions, in long-term hemodialysis patients with dysfunctional arteriovenous fistulas and grafts (AVF and AVG). Material and Methods. During a 17-month period, 31 patients with dysfunctional AVF and AVG (24 AVF and seven AVG) were examined with MDCTA with 3D image postprocessing. Parameters such as comprehension of the anatomy, quality of contrast enhancement, and pathological vascular changes were measured. DSA was then performed in 24 patients. Results. MDCTA illustrated the anatomy of the AVF/AVG and the entire vascular tree to the heart, in a detailed and comprehensive manner in 93.5% of the evaluated segments, and depicted pathology of AVF/AVG or pathology of the associated vasculature. MDCTA demonstrated a total of 38 significant stenoses in 25 patients. DSA verified 37 stenoses in 24 patients and demonstrated two additional stenoses. MDCTA had thus a sensitivity of 95%. All 24 patients were treated with percutaneous transluminal angioplasty (PTA) with good technical results. Conclusion. MDCTA with 3D reconstructions of dysfunctioning AVFs and AVGs in hemodialysis patients is an accurate and reliable diagnostic method helping customize future intervention

  4. Adipogenic differentiation of laser-printed 3D tissue grafts consisting of human adipose-derived stem cells

    International Nuclear Information System (INIS)

    Gruene, M; Deiwick, A; Koch, L; Schlie, S; Unger, C; Chichkov, B N; Pflaum, M; Wilhelmi, M; Haverich, A

    2011-01-01

    Laser-assisted bioprinting (LaBP) allows the realization of computer-generated 3D tissue grafts consisting of cells embedded in a hydrogel environment. In this study, human adipose-derived stem cells (hASCs) were printed in a free-scalable 3D grid pattern by means of LaBP. We demonstrate that neither the proliferation ability nor the differentiation behaviour of the stem cells was affected by the LaBP procedure. Furthermore, the 3D grafts were differentiated down the adipogenic lineage pathway for 10 days. We verify by quantitative assessments of adipogenic markers that the 3D grafts resemble cell lineages present in natural adipose tissue. Additionally, we provide the proof that even pre-differentiated hASCs could be utilized for the generation of 3D tissue grafts. These results indicate that the biofabrication of living grafts resembling their complex native origin is within reach.

  5. Adipogenic differentiation of laser-printed 3D tissue grafts consisting of human adipose-derived stem cells

    Energy Technology Data Exchange (ETDEWEB)

    Gruene, M; Deiwick, A; Koch, L; Schlie, S; Unger, C; Chichkov, B N [Nanotechnology Department, Laser Zentrum Hannover e.V., Hollerithallee 8, 30419 Hannover (Germany); Pflaum, M; Wilhelmi, M; Haverich, A, E-mail: m.gruene@lzh.de [Medizinische Hochschule Hannover, Carl-Neuberg-Strasse 1, 30625 Hannover (Germany)

    2011-03-15

    Laser-assisted bioprinting (LaBP) allows the realization of computer-generated 3D tissue grafts consisting of cells embedded in a hydrogel environment. In this study, human adipose-derived stem cells (hASCs) were printed in a free-scalable 3D grid pattern by means of LaBP. We demonstrate that neither the proliferation ability nor the differentiation behaviour of the stem cells was affected by the LaBP procedure. Furthermore, the 3D grafts were differentiated down the adipogenic lineage pathway for 10 days. We verify by quantitative assessments of adipogenic markers that the 3D grafts resemble cell lineages present in natural adipose tissue. Additionally, we provide the proof that even pre-differentiated hASCs could be utilized for the generation of 3D tissue grafts. These results indicate that the biofabrication of living grafts resembling their complex native origin is within reach.

  6. Punch grafts to treat lower limb intractable sores

    Directory of Open Access Journals (Sweden)

    JÚLIO WILSON FERNANDES

    Full Text Available ABSTRACT Lower limb recurrent ulcers, usually caused by prolonged decubitus, trauma, diabetes or burns, may not heal with conventional clinical or surgical treatment. Frequently, laminated skin grafts do not integrate with the recipient layer, and the only alternatives are neighbor microsurgical flaps. These have higher morbidity and create secondary defects, to be corrected with skin grafts, when fasciocutaneous or miocutaneous segments are removed for the treatment of the primary defect. We describe the non-conventional use of punch grafts in the treatment of lower limb ulcers, when conventional skin laminated graft failed, without the use of flaps. Since this is a very successful technique, its use should be considered as a valuable alternative for the treatment of recurrent lower limb ulcers. It is a simple and easy-learned technique that may be used by different surgeons, even in remote places without correct specialized hospital facilities.

  7. [Buccal mucosa graft augmented anastomotic urethroplasty for the treatment of bulbar urethral strictures].

    Science.gov (United States)

    Virasoro, Ramón; Storme, Oscar Alfonso; Capiel, Leandro; Ghisini, Diego Andrés; Rovegno, AugustÍn

    2015-12-01

    To report our outcomes with the use of buccal mucosal graft anastomotic urethroplasty to reconstruct complex anterior urethral strictures. Between October 2007 and January 2011 we conducted a retrospective review of a series of 65 patients from 2 different centers. We analyzed demographic data, surgical outcomes and complications. Patient mean age was 50.09 years (range: 25 to 75), mean stricture length was 3.95 cm (range: 3 to 7 cm) and mean follow-up 33.13 months (range: 12.7 to 52.77). Eighty percent of patients had prior treatments, mainly direct visual internal urethrotomy (DVIU) and urethral dilatation. Most frequent etiologies were iatrogenic in 46.15% of patients and idiopathic in 35.38% of patients. Success rate was achieved in 96.92% of patients; only 2 patients presented recurrence and were treated successfully with one DVIU. Clavien Dindo I-II complications were found in 59% of patients. No patient had chronic sequels. Augmented anastomotic urethroplasty using dorsal onlay buccal mucosa graft enables correction, in one time, of long segment urethral strictures with severe spongiofibrosis and/or obliterated lumen. Our outcomes are comparable with those of previously reported in international series.

  8. Graft irradiation abrogates graft-versus-host disease in combined pancreas-spleen transplantation

    International Nuclear Information System (INIS)

    Schulak, J.A.; Sharp, W.J.

    1986-01-01

    A model of combined pancreas-spleen transplantation (PST) was studied in LBN F1 recipients of Lewis grafts in order to evaluate the efficacy of pretransplant graft irradiation in preventing lethal graft-versus-host disease (GVHD). Recipients of unmodified PST uniformly developed severe GVHD and died (MST = 16.7 +/- 3.8 days). Whole body donor irradiation with either 500 or 250 rad prevented lethal GVHD. Similarly, ex vivo graft irradiation with either 1000 or 500 rad also resulted in normal weight gain, graft function, and host survival for the 6-week study period. Conversely, delay of graft irradiation until 3 days after transplantation failed to prevent this complication (MST = 15.8 +/- 3.7 days). Recipients of irradiated grafts displayed glucose tolerance tests that were identical to those in the control group indicating that the doses of radiation employed in these experiments were not deleterious to islet function. Irradiated spleen grafts appeared histologically normal at 6 weeks after transplantation. Cells derived from these grafts failed to stimulate lymph node enlargement in a popliteal lymph node assay for GVHD, suggesting that these spleens may have become repopulated with host cells. These experiments confirm that PST has the potential to cause lethal GVHD and suggest that pretransplant graft irradiation may be used to prevent its occurrence

  9. Entropic solvation force between surfaces modified by grafted chains: a density functional approach

    Directory of Open Access Journals (Sweden)

    O. Pizio

    2010-01-01

    Full Text Available The behavior of a hard sphere fluid in slit-like pores with walls modified by grafted chain molecules composed of hard sphere segments is studied using density functional theory. The chains are grafted to opposite walls via terminating segments forming pillars. The effects of confinement and of "chemical" modification of pore walls on the entropic solvation force are investigated in detail. We observe that in the absence of adsorbed fluid the solvation force is strongly repulsive for narrow pores and attractive for wide pores. In the presence of adsorbed fluid both parts of the curve of the solvation force may develop oscillatory behavior dependent on the density of pillars, the number of segments and adsorption conditions. Also, the size ratio between adsorbed fluid species and chain segments is of importance for the development of oscillations. The choice of these parameters is crucial for efficient manipulation of the solvation force as desired for pores of different width.

  10. Synthesis and properties of silane-fluoroacrylate grafted starch.

    Science.gov (United States)

    Qu, Jia; He, Ling

    2013-10-15

    The latex of silane-fluoroacrylate grafted starch for coating materials, VTMS-starch/P(MMA/BA/3FMA), is obtained by two step grafting reactions. Vinyltrimethoxysilane (VTMS) is primarily grafted onto starch by condensation between Si-OH and C-OH at 120 °C, and then the copolymer of methyl methacrylate (MMA), butyl acrylate (BA) and 2,2,2-trifluoroethyl methacrylate (3FMA) is grafted onto the VTMS-starch by emulsion polymerization. Fourier transform infrared spectrometry (FTIR) and X-ray photoelectron spectroscopy (XPS) have been used to confirm the chemically grafting reactions in every step. The conversion percent, grafting percent and grafting efficiency for VTMS-starch/p(MMA/BA/3FMA) latex indicate that the optimum conditions should be controlled at 75 °C for 1h as VTMS-starch/P(MMA/BA/3FMA) in 1/3 weight ratio. Transmission electron microscopy (TEM) and dynamic light scattering (DLS) analysis have revealed that the latexes exhibit the uniform spherical particles of 40-60 nm in a narrow size distribution. The latex films perform the obvious hydrophobic (107°) property, lower surface free energy (25-35 mN/m) and the higher thermostability (330-440 °C) than starch (51°, 51.32 mN/m, 100-330 °C). Dynamic thermomechanical analysis (DMA) shows that the latex film could gain considerable toughness and strength with an elongation at break of 39.45% and a tensile strength of 11.97 MPa. Copyright © 2013 Elsevier Ltd. All rights reserved.

  11. Experiences and Future Expectations towards Online Courses--An Empirical Study of the B2C-and B2B-Segments

    Science.gov (United States)

    Krämer, Andreas; Böhrs, Sandra

    2016-01-01

    This article explores the future potential for the development of online courses. The findings are based on an empirical study with 3 sample groups: (1) B2C segment in Germany, (2) B2C segment in the United States, and (3) B2B segment (international). In the first step the status quo of the use of e-learning in general and online courses in…

  12. Acromioclavicular joint reconstruction using a tendon graft: a biomechanical study comparing a novel “sutured throughout” tendon graft to a standard tendon graft

    Directory of Open Access Journals (Sweden)

    Naziri Qais

    2016-01-01

    Full Text Available Background: With a recurrence rate of over 30%, techniques that offer stronger acromioclavicular (AC joint reconstruction through increased graft strength may provide longevity. The purpose of our study was to determine the biomechanical strength of a novel tendon graft sutured throughout compared to a native tendon graft in Grade 3 anatomical AC joint reconstruction. Methods: For this in vitro experiment, nine paired (n = 18 embalmed cadaveric AC joints of three males and six females (age 86 years, range 51–94 years were harvested. Anatomic repair with fresh bovine Achilles tendon grafts without bone block was simulated. Specimens were divided into two groups; with group 1 using grafts with ultra-high molecular-weight polyethylene (UHMWPE suture ran throughout the entire length. In group 2, reconstruction with only native allografts was performed. The distal scapula and humerus were casted in epoxy compound and mounted on the mechanical testing machine. Tensile tests were performed using a mechanical testing machine at the rate of 50 mm/min. Maximum load and displacement to failure were collected. Results: The average load to failure was significantly higher for group 1 compared to group 2, with mean values of 437.5 N ± 160.7 N and 94.4 N ± 43.6 N, (p = 0.001. The average displacement to failure was not significantly different, with 29.7 mm ± 10.6 mm in group 1 and 25 mm ± 9.1 mm in group 2 (p = 0.25. Conclusion: We conclude that a UHMWPE suture reinforced graft can provide a 3.6 times stronger AC joint reconstruction compared to a native graft.

  13. Segmental Maxillary Distraction Osteogenesis With a Hybrid-Type Distractor in the Management of Wide Alveolar Cleft.

    Science.gov (United States)

    Zhang, Jianfei; Zhang, Wenbin; Shen, Steve Guofang

    2018-01-01

    To investigate segmental maxillary distraction osteogenesis (DO) with hybrid-type distractor in the management of wide alveolar cleft. Six patients underwent segmental DO with a hybrid-type distractor. After the success of DO and 3-month consolidation period, removal of the distractor was accompanied by alveolar bone graft with iliac bone. Panoramic radiograph and computed tomography scanning were taken preoperatively (T0) and the day after distractor removal (T1). The crest distance between the long axis of cleft nearby teeth was measured. All patients completed the DO period, and the succeeding alveolar bone graft healing was uneventful. The mean cleft distance decrease was 12.05 mm (range: 10.1-13.5 mm). As for the mobility degree record of abutment tooth in the transport segment recorded, 6 patients were grading I° at T0, while 5 patients were grading I° and 1 patient was grading II° at T1. Segmental maxillary DO with the hybrid-type distractor is successful to reduce the cleft width in these cases, and it is promising in the treatment of wide dental alveolar cleft, especially for the adult patient.

  14. Graft intolerance syndrome requiring graft nephrectomy after late kidney graft failure: can it be predicted? A retrospective cohort study.

    Science.gov (United States)

    Bunthof, Kim L W; Verhoeks, Carmen M; van den Brand, Jan A J G; Hilbrands, Luuk B

    2018-02-01

    Graft nephrectomy is recommended in case of early graft failure. When the graft fails more than 3-6 months after transplantation, it is current practice to follow a wait-and-see policy. A common indication for graft removal is the graft intolerance syndrome. We aimed to create a risk prediction model for the occurrence of graft intolerance resulting in graft nephrectomy. We collected data of kidney transplantations performed in our center between 1980 and 2010 that failed at least 6 months after transplantation. We evaluated the association between baseline characteristics and the occurrence of graft nephrectomy because of graft intolerance using a competing risk regression model. Prognostic factors were included in a multivariate prediction model. In- and exclusion criteria were met in 288 cases. In 48 patients, the graft was removed because of graft intolerance. Donor age, the number of rejections, and shorter graft survival were predictive factors for graft nephrectomy because of the graft intolerance syndrome. These factors were included in a prediction rule. Using donor age, graft survival, and the number of rejections, clinicians can predict the need for graft nephrectomy with a reasonable accuracy. © 2017 Steunstichting ESOT.

  15. Segmentation of multiple heart cavities in 3-D transesophageal ultrasound images.

    Science.gov (United States)

    Haak, Alexander; Vegas-Sánchez-Ferrero, Gonzalo; Mulder, Harriët W; Ren, Ben; Kirişli, Hortense A; Metz, Coert; van Burken, Gerard; van Stralen, Marijn; Pluim, Josien P W; van der Steen, Antonius F W; van Walsum, Theo; Bosch, Johannes G

    2015-06-01

    Three-dimensional transesophageal echocardiography (TEE) is an excellent modality for real-time visualization of the heart and monitoring of interventions. To improve the usability of 3-D TEE for intervention monitoring and catheter guidance, automated segmentation is desired. However, 3-D TEE segmentation is still a challenging task due to the complex anatomy with multiple cavities, the limited TEE field of view, and typical ultrasound artifacts. We propose to segment all cavities within the TEE view with a multi-cavity active shape model (ASM) in conjunction with a tissue/blood classification based on a gamma mixture model (GMM). 3-D TEE image data of twenty patients were acquired with a Philips X7-2t matrix TEE probe. Tissue probability maps were estimated by a two-class (blood/tissue) GMM. A statistical shape model containing the left ventricle, right ventricle, left atrium, right atrium, and aorta was derived from computed tomography angiography (CTA) segmentations by principal component analysis. ASMs of the whole heart and individual cavities were generated and consecutively fitted to tissue probability maps. First, an average whole-heart model was aligned with the 3-D TEE based on three manually indicated anatomical landmarks. Second, pose and shape of the whole-heart ASM were fitted by a weighted update scheme excluding parts outside of the image sector. Third, pose and shape of ASM for individual heart cavities were initialized by the previous whole heart ASM and updated in a regularized manner to fit the tissue probability maps. The ASM segmentations were validated against manual outlines by two observers and CTA derived segmentations. Dice coefficients and point-to-surface distances were used to determine segmentation accuracy. ASM segmentations were successful in 19 of 20 cases. The median Dice coefficient for all successful segmentations versus the average observer ranged from 90% to 71% compared with an inter-observer range of 95% to 84%. The

  16. Preliminary study of coconut water for graft tissues preservation in transplantation.

    Science.gov (United States)

    César, Jorge Miguel Schettino; Petroianu, Andy; Vasconcelos, Leonardo de Souza; Cardoso, Valbert Nascimento; Mota, Luciene das Graças; Barbosa, Alfredo José Afonso; Soares, Cristina Duarte Vianna; de Oliveira, Amanda Lima

    2015-01-01

    to verify the effectiveness of coconut water in preserving tissues for transplant. Fifty male Wistar rats were randomly distributed in five groups, according to the following preservation solutions for tissue grafts: Group 1: Lactated Ringer; Group 2: Belzer solution; Group 3: mature coconut water; Group 4: green coconut water; Group 5: modified coconut water. In Group 5, the green coconut water has been modified like the Belzer solution. From each animal we harvested the spleen, ovaries and skin of the back segment. These tissues were preserved for six hours in one of the solutions. Then, the grafts were reimplanted. The recovery of the function of the implanted tissues was assessed 90 days after surgery, by splenic scintigraphy and blood exam. The implanted tissues were collected for histopathological examination. The serum levels did not differ among groups, except for the animals in Group 5, which showed higher levels of IgG than Group 1, and differences in relation to FSH between groups 1 and 2 (p coconut water (p coconut water-based solutions preserves spleen, ovary, and rat skin for six hours, maintaining their normal function.

  17. Solitary haemangioma of the shaft of long bones: resection and reconstruction with autologous bone graft.

    Science.gov (United States)

    Li, Zhaoxu; Tang, Jicun; Ye, Zhaoming

    2013-04-01

    Bone haemangiomas are uncommon lesions, occurring in the skull or spine. A solitary haemangioma in the diaphysis of a long bone is rare. We retrospectively investigated six patients who presented with a solitary haemangioma in a long bone diaphysis. After segmental bone resection, the bone defect was replaced by a bone autograft. Patients were reviewed clinically and with radiographs. The mean follow-up was 6 years (range : 1-20 years). At the time of latest follow-up, no patient had a recurrence. Postoperative complications were one wound necrosis and one superficial wound infection. Union of the gap filling graft with the host bone was achieved in all patients at an average of 4 months (range: 3-8 months). The average Musculoskeletal Tumor Society functional score was 77% (range: 53%-90%) of normal at 6 months postoperatively, and 97% (range: 95%-99%) at the last follow-up evaluation. Segmental resection for solitary haemangioma and reconstruction with autologous bone graft can be considered as a suitable treatment option.

  18. 3D-SIFT-Flow for atlas-based CT liver image segmentation.

    Science.gov (United States)

    Xu, Yan; Xu, Chenchao; Kuang, Xiao; Wang, Hongkai; Chang, Eric I-Chao; Huang, Weimin; Fan, Yubo

    2016-05-01

    In this paper, the authors proposed a new 3D registration algorithm, 3D-scale invariant feature transform (SIFT)-Flow, for multiatlas-based liver segmentation in computed tomography (CT) images. In the registration work, the authors developed a new registration method that takes advantage of dense correspondence using the informative and robust SIFT feature. The authors computed the dense SIFT features for the source image and the target image and designed an objective function to obtain the correspondence between these two images. Labeling of the source image was then mapped to the target image according to the former correspondence, resulting in accurate segmentation. In the fusion work, the 2D-based nonparametric label transfer method was extended to 3D for fusing the registered 3D atlases. Compared with existing registration algorithms, 3D-SIFT-Flow has its particular advantage in matching anatomical structures (such as the liver) that observe large variation/deformation. The authors observed consistent improvement over widely adopted state-of-the-art registration methods such as ELASTIX, ANTS, and multiatlas fusion methods such as joint label fusion. Experimental results of liver segmentation on the MICCAI 2007 Grand Challenge are encouraging, e.g., Dice overlap ratio 96.27% ± 0.96% by our method compared with the previous state-of-the-art result of 94.90% ± 2.86%. Experimental results show that 3D-SIFT-Flow is robust for segmenting the liver from CT images, which has large tissue deformation and blurry boundary, and 3D label transfer is effective and efficient for improving the registration accuracy.

  19. Prolongation of segmental and pancreaticoduodenal allografts in the primate with total-lymphoid irradiation and cyclosporine

    Energy Technology Data Exchange (ETDEWEB)

    Du Toit, D.F.; Heydenrych, J.J.; Smit, B.; Louw, G.; Zuurmond, T.; Els, D.; Du Toit, L.B.; Weideman, A.; Davids, H.; van der Merwe, E.

    1987-09-01

    The prolongation of segmental and pancreaticoduodenal allografts (PDA) by total lymphoid irradiation (TLI) and in combination with cyclosporine (CsA) was assessed in a well established total pancreatectomy, diabetic, primate transplantation model. Pancreatic transplantation was performed in 119 pancreatectomized baboons (Papio ursinus). Of a total of 109 allografts performed, 71 were segmental allografts (open duct drainage) and 38 PDA. Of 119 graft recipients, 10 received segmental pancreatic autografts. TLI and CsA administered separately to segmental allograft recipients resulted in modest allograft survival and indefinite graft survival was not observed. 8 of 17 (47%) segmental allograft recipients that received TLI and CsA had graft survival beyond 100 days, indicating highly significant pancreatic allograft survival. All long-term segmental allograft recipients were rendered normoglycemic (plasma glucose less than 8 mmol/L) by this immunosuppressive regimen. In contrast, poor results were observed in PDA recipients treated with TLI and CsA. Mean survival in 18 treated PDA recipients was 23.8 days, 8 survived longer than 20 days (44.4%), and 1 greater than 100 days (5.5%). Despite treatment, early rejection of the duodenum in PDA recipients frequently resulted in necrosis and perforation and contributed to a high morbidity and mortality. This study indicates that, in contrast to the significant prolongation of segmental allografts by TLI and CsA, poor immunosuppression was achieved by this regimen in PDA recipients and was associated with a high morbidity and mortality caused by early rejection of the duodenum.

  20. Prolongation of segmental and pancreaticoduodenal allografts in the primate with total-lymphoid irradiation and cyclosporine

    International Nuclear Information System (INIS)

    Du Toit, D.F.; Heydenrych, J.J.; Smit, B.

    1987-01-01

    The prolongation of segmental and pancreaticoduodenal allografts (PDA) by total lymphoid irradiation (TLI) and in combination with cyclosporine (CsA) was assessed in a well established total pancreatectomy, diabetic, primate transplantation model. Pancreatic transplantation was performed in 119 pancreatectomized baboons (Papio ursinus). Of a total of 109 allografts performed, 71 were segmental allografts (open duct drainage) and 38 PDA. Of 119 graft recipients, 10 received segmental pancreatic autografts. TLI and CsA administered separately to segmental allograft recipients resulted in modest allograft survival and indefinite graft survival was not observed. 8 of 17 (47%) segmental allograft recipients that received TLI and CsA had graft survival beyond 100 days, indicating highly significant pancreatic allograft survival. All long-term segmental allograft recipients were rendered normoglycemic (plasma glucose less than 8 mmol/L) by this immunosuppressive regimen. In contrast, poor results were observed in PDA recipients treated with TLI and CsA. Mean survival in 18 treated PDA recipients was 23.8 days, 8 survived longer than 20 days (44.4%), and 1 greater than 100 days (5.5%). Despite treatment, early rejection of the duodenum in PDA recipients frequently resulted in necrosis and perforation and contributed to a high morbidity and mortality. This study indicates that, in contrast to the significant prolongation of segmental allografts by TLI and CsA, poor immunosuppression was achieved by this regimen in PDA recipients and was associated with a high morbidity and mortality caused by early rejection of the duodenum

  1. Reexamination of the role of Lyt-2-positive T cells in murine skin graft rejection

    International Nuclear Information System (INIS)

    LeFrancois, L.; Bevan, M.J.

    1984-01-01

    The authors have investigated which T cell subclass defined by cytolysis with monoclonal anti-Lyt-1.2 and anti-Lyt-2.2 antibodies is required to adoptively transfer the ability to reject skin grafts. B6.Thy-1.1 spleen cells immune to graft antigens were fractionated with antibody plus C' and transferred to adult thymectomized, irradiated, bone marrow-reconstituted (ATXBM) B6.Thy-1.2 hosts that were simultaneously grafted with BALB.B skin. The authors found that when the ATXBM hosts were used 6 wk after irradiation and marrow reconstitution, both Lyt-1-depleted and Lyt-2-depleted immune spleen cells could transfer the ability to promptly reject skin grafts. However, such ATXBM recipients of Lyt-2-depleted cells that had rejected skin grafts were found to contain graft-specific CTL that were largely of host (B6.Thy-1.2) origin. When ATXBM hosts were used for the experiment 1 wk after irradiation and marrow reconstitution, no host-derived graft-specific CTL could be detected. However, graft rejection occurred in recipients of anti-Lyt-1- or anti-Lyt-2 plus C'-treated immune cells and specific CTL were generated from spleen cells of both groups. Thus, in the absence of a host-derived response, adoptively transferred immune Lyt-2+ cells, either resistant to, or that escaped from, antibody plus C' treatment, are able to expand in response to the antigenic stimulus provided by the graft. A more complete elimination of specific T cell subclasses is therefore needed to assess the relative contribution of a particular subset to the graft rejection process

  2. Development and Assessment of a 3D-Printed Scaffold with rhBMP-2 for an Implant Surgical Guide Stent and Bone Graft Material: A Pilot Animal Study

    Directory of Open Access Journals (Sweden)

    Ji Cheol Bae

    2017-12-01

    Full Text Available In this study, a new concept of a 3D-printed scaffold was introduced for the accurate placement of an implant and the application of a recombinant human bone morphogenetic protein-2 (rhBMP-2-loaded bone graft. This preliminary study was conducted using two adult beagles to evaluate the 3D-printed polycaprolactone (PCL/β-tricalcium phosphate (β-TCP/bone decellularized extracellular matrix (bdECM scaffold conjugated with rhBMP-2 for the simultaneous use as an implant surgical guide stent and bone graft material that promotes new bone growth. Teeth were extracted from the mandible of the beagle model and scanned by computed tomography (CT to fabricate a customized scaffold that would fit the bone defect. After positioning the implant guide scaffold, the implant was placed and rhBMP-2 was injected into the scaffold of the experimental group. The two beagles were sacrificed after three months. The specimen block was obtained and scanned by micro-CT. Histological analysis showed that the control and experimental groups had similar new bone volume (NBV, % but the experimental group with BMP exhibited a significantly higher bone-to-implant contact ratio (BIC, %. Within the limitations of this preliminary study, a 3D-printed scaffold conjugated with rhBMP-2 can be used simultaneously as an implant surgical guide and a bone graft in a large bone defect site. Further large-scale studies will be needed to confirm these results.

  3. Development and Assessment of a 3D-Printed Scaffold with rhBMP-2 for an Implant Surgical Guide Stent and Bone Graft Material: A Pilot Animal Study

    Science.gov (United States)

    Bae, Ji Cheol; Lee, Jin-Ju; Shim, Jin-Hyung; Park, Keun-Ho; Lee, Jeong-Seok; Bae, Eun-Bin; Choi, Jae-Won; Huh, Jung-Bo

    2017-01-01

    In this study, a new concept of a 3D-printed scaffold was introduced for the accurate placement of an implant and the application of a recombinant human bone morphogenetic protein-2 (rhBMP-2)-loaded bone graft. This preliminary study was conducted using two adult beagles to evaluate the 3D-printed polycaprolactone (PCL)/β-tricalcium phosphate (β-TCP)/bone decellularized extracellular matrix (bdECM) scaffold conjugated with rhBMP-2 for the simultaneous use as an implant surgical guide stent and bone graft material that promotes new bone growth. Teeth were extracted from the mandible of the beagle model and scanned by computed tomography (CT) to fabricate a customized scaffold that would fit the bone defect. After positioning the implant guide scaffold, the implant was placed and rhBMP-2 was injected into the scaffold of the experimental group. The two beagles were sacrificed after three months. The specimen block was obtained and scanned by micro-CT. Histological analysis showed that the control and experimental groups had similar new bone volume (NBV, %) but the experimental group with BMP exhibited a significantly higher bone-to-implant contact ratio (BIC, %). Within the limitations of this preliminary study, a 3D-printed scaffold conjugated with rhBMP-2 can be used simultaneously as an implant surgical guide and a bone graft in a large bone defect site. Further large-scale studies will be needed to confirm these results. PMID:29258172

  4. Effects of solvents on the radiation grafting reaction of vinyl compounds on poly (3-hydroxybutyrate)

    International Nuclear Information System (INIS)

    Torres, Maykel González; Talavera, José Rogelio Rodríguez; Muñoz, Susana Vargas; Pérez, Manuel González; Castro, Ma. Pilar. Carreón.; Cortes, Jorge Cerna

    2015-01-01

    Vinyl Acetate was grafted onto poly (3-hydroxybutyrate) by the simultaneous gamma irradiation method using different types of solvents and in bulk (solvent free), at 10 kGy and 1.62 kGy/h dose and dose rate respectively. Subsequent complete hydrolysis allowed the conversion of grafted chains from poly (vinyl acetate) to poly (vinyl alcohol). The aim of this study is to determine the effect of solvent through the estimation of the dependence of the degree of grafting with the choice of solvent, the calculation of the degree of crystallinity, and to study the biodegradation of the products. The results showed a greater degree of grafting in bulk, while the more suitable solvent was hexane. Characterization of the grafted copolymer indicated that crystallinity percentage decreased by an increase in grafting, while the biodegradability was promoted by the increment in poly (vinyl alcohol) grafted. - Highlights: • PHB was indirectly grafted with PVA, by complete hydrolysis of grafted PVAc. • The effect of solvents on the grafting, crystallinity and biodegradation was studied. • The characterizations of the products were obtained by SEM, TGA, and DSC

  5. [Treatment of thoracolumbar burst fracture with lateral anterior decompression, internal fixation with Ventrofix and bone graft with titanic mesh].

    Science.gov (United States)

    Zhang, Shi-min; Zhang, Zhao-jie; Liu, Yu-zhang; Zhang, Lu-tang; Li, Xing

    2011-11-01

    To discuss the efficacy of lateral anterior decompression, internal fixation with Ventrofix and bone graft with titanic mesh in the treatment of severe thoracolumbar burst fracture. From January 2008 to January 2010, 21 patients with severe thoracolumbar burst fracture were treated with lateral anterior decompression, internal fixation with Ventrofix, bone graft with titanic mesh. There were 15 males and 6 females, ranging in age from 21 to 46 years with an average of 32.2 years. Segment of fracture: 3 cases were in T11, 6 cases in T12, 7 cases in L1, 5 cases in L2. The mean kyphosis angle was 20.1 degrees and loading of fracture was 7.8 scores. Twenty-one cases accompany with incomplete paralysis. Nerves functions were observed according to Frankel grade; correction and maintain of kyphosis angle were observed by X-rays and CT. All the patients were followed up from 12 to 34 months with an average of 18.5 years. Postoperative complication including injury of pleura in 1 case, dynamic ileus in 2 cases, ilioinguinal nerve injury in 1 case, faulty union of wound in 1 case. All the above complications got recovery after symptomatic treatment. The mean kyphosis angle in fusional segment were 4.2 degrees and the rate of correction was 79%. Nerves functions of all patients got improvement and no internal fixation fail, kyphosis angle obviously lost, titanium mesh shifting, loosening and breakage of screw were found at final follow-up. Lateral anterior decompression, bone graft with titanic mesh, internal fixation with Ventrofix is an idea technique for severe thoracolumber burst fracture, but the method can not be used for patient with severity osteoporosis.

  6. Accuracy of Estimation of Graft Size for Living-Related Liver Transplantation: First Results of a Semi-Automated Interactive Software for CT-Volumetry

    Science.gov (United States)

    Mokry, Theresa; Bellemann, Nadine; Müller, Dirk; Lorenzo Bermejo, Justo; Klauß, Miriam; Stampfl, Ulrike; Radeleff, Boris; Schemmer, Peter; Kauczor, Hans-Ulrich; Sommer, Christof-Matthias

    2014-01-01

    Objectives To evaluate accuracy of estimated graft size for living-related liver transplantation using a semi-automated interactive software for CT-volumetry. Materials and Methods Sixteen donors for living-related liver transplantation (11 male; mean age: 38.2±9.6 years) underwent contrast-enhanced CT prior to graft removal. CT-volumetry was performed using a semi-automated interactive software (P), and compared with a manual commercial software (TR). For P, liver volumes were provided either with or without vessels. For TR, liver volumes were provided always with vessels. Intraoperative weight served as reference standard. Major study goals included analyses of volumes using absolute numbers, linear regression analyses and inter-observer agreements. Minor study goals included the description of the software workflow: degree of manual correction, speed for completion, and overall intuitiveness using five-point Likert scales: 1–markedly lower/faster/higher for P compared with TR, 2–slightly lower/faster/higher for P compared with TR, 3–identical for P and TR, 4–slightly lower/faster/higher for TR compared with P, and 5–markedly lower/faster/higher for TR compared with P. Results Liver segments II/III, II–IV and V–VIII served in 6, 3, and 7 donors as transplanted liver segments. Volumes were 642.9±368.8 ml for TR with vessels, 623.8±349.1 ml for P with vessels, and 605.2±345.8 ml for P without vessels (Pvolumetry performed with P can predict accurately graft size for living-related liver transplantation while improving workflow compared with TR. PMID:25330198

  7. Ventral onlay graft bulbar urethroplasty using buccal mucosa

    African Journals Online (AJOL)

    H. Wessells

    2016-01-21

    Jan 21, 2016 ... been disseminated for a longer time interval than dorsal. When a segment of a ... the graft and allowed to heal by secondary intention (see Fig. ... complications is influenced by use of Trendelenberg, knee posi- tion, external .... prostatectomy, radiation, straddle injury, or pelvic fracture cre- ates obliteration ...

  8. 3D computed tomographic evaluation of secondary alveolar bone grafts in cleft lip and palate patients

    Energy Technology Data Exchange (ETDEWEB)

    Ohkubo, Fumio; Akai, Hidemi; Hosaka, Yoshiaki [Showa Univ., Tokyo (Japan). School of Medicine

    2001-04-01

    Alveolar bone grafting in patients with cleft lip and palate has becomes a routine part of most treatment regimes. This study was undertaken to estimate how much bone needs to be grafted into the cleft cavity and to evaluate the grafted bone using 3-DCT over a period from the early postoperative stage to after one year. Seventy-five patients divided into four groups according to the type of cleft were studied. All patients underwent secondary alveolar bone grafting using particulate cancellous bone from the anterior iliac crest. The bone graft areas were divided into two regions: the extra-cleft region and the intra-cleft region. The weight and the volume of the grafted bone were correlated and the average density was 1.5 g/ml regardless of the cleft type. The bone in the extra-cleft region could be seen in almost all slices of the CT scans, from the lower alveolar process to the piriform aperture. The extra-cleft graft ratio of unilateral and bilateral cleft lip and palate is higher than that of cleft lip and alveolus. The extra-cleft grafting is necessary to restore facial symmetry. The grafted bone was decreased in both height and volume following three months and adequate bone bridging was maintained for one year. We concluded that 3-DCT findings are one of the most valuable methods to evaluate postoperative conditions after alveolar bone grafting. (author)

  9. 3D computed tomographic evaluation of secondary alveolar bone grafts in cleft lip and palate patients

    International Nuclear Information System (INIS)

    Ohkubo, Fumio; Akai, Hidemi; Hosaka, Yoshiaki

    2001-01-01

    Alveolar bone grafting in patients with cleft lip and palate has becomes a routine part of most treatment regimes. This study was undertaken to estimate how much bone needs to be grafted into the cleft cavity and to evaluate the grafted bone using 3-DCT over a period from the early postoperative stage to after one year. Seventy-five patients divided into four groups according to the type of cleft were studied. All patients underwent secondary alveolar bone grafting using particulate cancellous bone from the anterior iliac crest. The bone graft areas were divided into two regions: the extra-cleft region and the intra-cleft region. The weight and the volume of the grafted bone were correlated and the average density was 1.5 g/ml regardless of the cleft type. The bone in the extra-cleft region could be seen in almost all slices of the CT scans, from the lower alveolar process to the piriform aperture. The extra-cleft graft ratio of unilateral and bilateral cleft lip and palate is higher than that of cleft lip and alveolus. The extra-cleft grafting is necessary to restore facial symmetry. The grafted bone was decreased in both height and volume following three months and adequate bone bridging was maintained for one year. We concluded that 3-DCT findings are one of the most valuable methods to evaluate postoperative conditions after alveolar bone grafting. (author)

  10. 3D-SIFT-Flow for atlas-based CT liver image segmentation

    Energy Technology Data Exchange (ETDEWEB)

    Xu, Yan, E-mail: xuyan04@gmail.com [State Key Laboratory of Software Development Environment and Key Laboratory of Biomechanics and Mechanobiology of Ministry of Education, Beihang University, Beijing 100191, China and Research Institute of Beihang University in Shenzhen and Microsoft Research, Beijing 100080 (China); Xu, Chenchao, E-mail: chenchaoxu33@gmail.com; Kuang, Xiao, E-mail: kuangxiao.ace@gmail.com [School of Biological Science and Medical Engineering, Beihang University, Beijing 100191 (China); Wang, Hongkai, E-mail: wang.hongkai@gmail.com [Department of Biomedical Engineering, Dalian University of Technology, Dalian 116024 (China); Chang, Eric I-Chao, E-mail: eric.chang@microsoft.com [Microsoft Research, Beijing 100080 (China); Huang, Weimin, E-mail: wmhuang@i2r.a-star.edu.sg [Institute for Infocomm Research (I2R), Singapore 138632 (Singapore); Fan, Yubo, E-mail: yubofan@buaa.edu.cn [Key Laboratory of Biomechanics and Mechanobiology of Ministry of Education, Beihang University, Beijing 100191 (China)

    2016-05-15

    Purpose: In this paper, the authors proposed a new 3D registration algorithm, 3D-scale invariant feature transform (SIFT)-Flow, for multiatlas-based liver segmentation in computed tomography (CT) images. Methods: In the registration work, the authors developed a new registration method that takes advantage of dense correspondence using the informative and robust SIFT feature. The authors computed the dense SIFT features for the source image and the target image and designed an objective function to obtain the correspondence between these two images. Labeling of the source image was then mapped to the target image according to the former correspondence, resulting in accurate segmentation. In the fusion work, the 2D-based nonparametric label transfer method was extended to 3D for fusing the registered 3D atlases. Results: Compared with existing registration algorithms, 3D-SIFT-Flow has its particular advantage in matching anatomical structures (such as the liver) that observe large variation/deformation. The authors observed consistent improvement over widely adopted state-of-the-art registration methods such as ELASTIX, ANTS, and multiatlas fusion methods such as joint label fusion. Experimental results of liver segmentation on the MICCAI 2007 Grand Challenge are encouraging, e.g., Dice overlap ratio 96.27% ± 0.96% by our method compared with the previous state-of-the-art result of 94.90% ± 2.86%. Conclusions: Experimental results show that 3D-SIFT-Flow is robust for segmenting the liver from CT images, which has large tissue deformation and blurry boundary, and 3D label transfer is effective and efficient for improving the registration accuracy.

  11. 3D-SIFT-Flow for atlas-based CT liver image segmentation

    International Nuclear Information System (INIS)

    Xu, Yan; Xu, Chenchao; Kuang, Xiao; Wang, Hongkai; Chang, Eric I-Chao; Huang, Weimin; Fan, Yubo

    2016-01-01

    Purpose: In this paper, the authors proposed a new 3D registration algorithm, 3D-scale invariant feature transform (SIFT)-Flow, for multiatlas-based liver segmentation in computed tomography (CT) images. Methods: In the registration work, the authors developed a new registration method that takes advantage of dense correspondence using the informative and robust SIFT feature. The authors computed the dense SIFT features for the source image and the target image and designed an objective function to obtain the correspondence between these two images. Labeling of the source image was then mapped to the target image according to the former correspondence, resulting in accurate segmentation. In the fusion work, the 2D-based nonparametric label transfer method was extended to 3D for fusing the registered 3D atlases. Results: Compared with existing registration algorithms, 3D-SIFT-Flow has its particular advantage in matching anatomical structures (such as the liver) that observe large variation/deformation. The authors observed consistent improvement over widely adopted state-of-the-art registration methods such as ELASTIX, ANTS, and multiatlas fusion methods such as joint label fusion. Experimental results of liver segmentation on the MICCAI 2007 Grand Challenge are encouraging, e.g., Dice overlap ratio 96.27% ± 0.96% by our method compared with the previous state-of-the-art result of 94.90% ± 2.86%. Conclusions: Experimental results show that 3D-SIFT-Flow is robust for segmenting the liver from CT images, which has large tissue deformation and blurry boundary, and 3D label transfer is effective and efficient for improving the registration accuracy.

  12. Similar Outcomes in Diabetes Patients After Coronary Artery Bypass Grafting With Single Internal Thoracic Artery Plus Radial Artery Grafting and Bilateral Internal Thoracic Artery Grafting.

    Science.gov (United States)

    Raza, Sajjad; Blackstone, Eugene H; Houghtaling, Penny L; Koprivanac, Marijan; Ravichandren, Kirthi; Javadikasgari, Hoda; Bakaeen, Faisal G; Svensson, Lars G; Sabik, Joseph F

    2017-12-01

    The purpose of this study was to determine in patients with diabetes mellitus whether single internal thoracic artery (SITA) plus radial artery (RA) grafting yields outcomes similar to those of bilateral internal thoracic artery (BITA) grafting. From January 1994 to January 2011, 1,325 diabetic patients underwent primary isolated coronary artery bypass graft surgery with either (1) SITA plus RA with or without saphenous vein (SV) grafts (n = 965) or (2) BITA with or without SV grafts (n = 360); an internal thoracic artery was used in all patients to graft the left anterior descending coronary artery. Endpoints were in-hospital outcomes and time-related mortality. Median follow-up was 7.4 years, with a total follow-up of 9,162 patient-years. Propensity score matching was performed to identify 282 well-matched pairs for adjusted comparisons. Unadjusted in-hospital mortality was 0.52% for SITA plus RA with or without SV grafts and 0.28% for BITA with or without SV grafts, and prevalence of deep sternal wound infection was 3.2% and 1.7%, respectively. Unadjusted survival at 1, 5, 10, and 14 years was 97%, 88%, 68%, and 51% for SITA plus RA with or without SV grafts, and 97%, 95%, 80%, and 66% for BITA with or without SV grafts, respectively. Among propensity-matched patients, in-hospital mortality (0.35% versus 0.35%) and prevalence of deep sternal wound infection (1.4% versus 1.4%) were similar (p > 0.9) in the two groups, as was 1-, 5-, 10-, and 14-year survival: 97%, 90%, 70%, and 58% for SITA plus RA with or without SV grafting versus 97%, 93%, 79%, and 64% for BITA with or without SV grafting, respectively (early p = 0.8, late p = 0.2). For diabetic patients, SITA plus RA with or without SV grafting and BITA with or without SV grafting yield similar in-hospital outcomes and long-term survival after coronary artery bypass graft surgery. Therefore, both SITA plus RA and BITA plus SV grafting should be considered for these patients. Copyright © 2017 The Society

  13. Thalamus segmentation from MP2RAGE: a comparative study

    DEFF Research Database (Denmark)

    Eskildsen, Simon Fristed; Næss-Schmidt, Erhard; Blicher, Jakob

    RAGE sequence on a Siemens Magnetom Skyra 3T MRI system with a 32 channel head coil. Parameters were TR=5 s, TI1=0.7 s, TI2=2.5 s, α1=4°, α2=5° and acquired at a nominal, isotropic, resolution of 1mm (acquisition matrix: 240x256, 176 sagittal slices). An experienced neuro-radiologist manually traced......, increasing the number of training images in the library of SNIPE improves segmentation accuracy (Figure 4). Even though the DSI seems to plateau around a library size of 10-11 images, increasing the library may improve the accuracy even further. Conclusions: Widely used atlas based segmentation methods...

  14. MRI of double-bundle ACL reconstruction: evaluation of graft findings

    Energy Technology Data Exchange (ETDEWEB)

    Kiekara, Tommi; Paakkala, Antti [Tampere University Hospital, Medical Imaging Centre, Tampere (Finland); Jaervelae, Timo [Sports Clinic and Hospital Mehilaeinen, Tampere (Finland); Huhtala, Heini [University of Tampere, School of Health Sciences, Tampere (Finland)

    2012-07-15

    To demonstrate the magnetic resonance imaging (MRI) findings of double-bundle (DB) anterior cruciate ligament (ACL) reconstruction grafts. Sixty-six patients with DB ACL reconstruction were evaluated with MRI 2 years postoperatively. Graft thickness was measured separately by two musculoskeletal radiologists. The MRI findings of graft disruption, signal intensity (SI) changes, cystic degeneration, arthrofibrosis, and impingement were analyzed. The statistical significance of the association between MRI findings was calculated. The mean anteromedial (AM) graft thickness was reduced 9% and the mean posterolateral (PL) graft thickness was reduced 18% from the original graft thickness. Disruption was seen in 3% of AM grafts and 6% of PL grafts and a partial tear in 8 and 23%, respectively. Both grafts were disrupted in 3% of patients. Increased SI was seen in 14% of intact AM grafts and in 60% of partially torn AM grafts (p = 0.032). In PL grafts the increased SI was seen in 51% of the intact grafts and in 93% of the partially torn grafts (p = 0.005). Cystic degeneration was seen in 8% of AM grafts and in 5% of PL grafts. Diffuse arthrofibrosis was seen in 5% of patients and a localized cyclops lesion in 3% of patients. Impingement of the AM graft was seen in 8% of patients. Both grafts were disrupted in 3% of patients. Also, the frequencies of other complications were low. The use of orthogonal sequences in the evaluation of the PL graft SI seems to cause volume-averaging artefacts. (orig.)

  15. Does site of buccal mucosa graft for bulbar urethra stricture affect outcome? A comparative analysis of ventral, dorso-lateral and dorsal buccal mucosa graft augmentation urethroplasty.

    Science.gov (United States)

    Pathak, Hemant R; Jain, Tarunkumar Prakash; Bhujbal, Sachin A; Meshram, Kunal R; Gadekar, Chetan; Parab, Sandesh

    2017-09-01

    To compare long- term outcomes of buccal mucosa graft (BMG) augmentation urethroplasty for long segment bulbar urethral strictures done by placing the graft ventrally, dorso-laterally and dorsally. We conducted a single institution retrospective study on 112 who underwent BMG augmentation urethroplasty for non-traumatic bulbar urethral strictures between January 2005 to December 2014. The cases were divided into three groups based on the site of placement of BMG graft i.e. (a) Ventral (n=44), (b) Dorso-lateral (n=48) and (c) Dorsal (n=20). Follow-up period was from one year to five years. Patients with failed outcomes underwent urethroscopy or retrograde urethrogram to note the site of recurrence of stricture. Out of 112 cases 91 (81%) were successful and 21 (19%) failed. The success rates for ventral, dorso-lateral and dorsal BMG augmentation procedures were 89%, 79% and 70%, respectively (p=0.18). Among 21 failed cases, 12 cases (57%) had stricture at proximal anastomotic site, 4 cases (19%) at graft and 5 cases (24%) at distal anastomotic site (p=0.01). The overall success rate for BMG augmentation urethroplasty is equal for all techniques. Ventral onlay urethroplasty provides better exposure of proximal anastomotic site thus it is associated with minimum proximal anastomotic site recurrence rates. Patients with extensive spongiofibrosis and long segment strictures had higher rates of failure.

  16. Identification of β-Amino alcohol grafted 1,4,5 trisubstituted 1,2,3-triazoles as potent antimalarial agents.

    Science.gov (United States)

    Devender, Nalmala; Gunjan, Sarika; Chhabra, Stuti; Singh, Kartikey; Pasam, Venkata Reddy; Shukla, Sanjeev K; Sharma, Abhisheak; Jaiswal, Swati; Singh, Sunil Kumar; Kumar, Yogesh; Lal, Jawahar; Trivedi, Arun Kumar; Tripathi, Renu; Tripathi, Rama Pati

    2016-02-15

    In a quest to discover new drugs, we have synthesized a series of novel β-amino alcohol grafted 1,2,3-triazoles and screened them for their in vitro antiplasmodial and in vivo antimalarial activity. Among them, compounds 16 and 25 showed potent activity against chloroquine-sensitive (Pf3D7) strain with IC50 of 0.87 and 0.3 μM respectively, while compounds 7 and 13 exhibited better activity in vitro than the reference drug against chloroquine-resistance strain (PfK1) with IC50 of 0.5 μM each. Compound 25 showed 86.8% in vivo antimalarial efficacy with favorable pharmacokinetic parameters. Mechanistic studies divulged that potent compounds significantly boosted p53 protein levels to exhibit the antimalarial activity. Copyright © 2015 Elsevier Masson SAS. All rights reserved.

  17. Quantification of deposition of neutrophilic granulocytes on vascular grafts in dogs with 111In-labeled granulocytes

    International Nuclear Information System (INIS)

    Dewanjee, M.K.; Solis, E.; Mackey, S.T.; Socher, S.; Chowdhury, S.; Wu, F.P.; Kaye, M.P.

    1985-01-01

    A new radioisotopic technique has been developed for quantification of deposition of neutrophilic granulocytes on vascular grafts. Nine healthy mongrel dogs underwent bilateral femoral artery resection and reconstruction with grafts of the femoral vein and Gore-Tex. Pure granulocytes that had been separated from whole blood by centrifugal elutriation were labeled with 111 In-tropolone in plasma. The granulocyte harvesting efficiency was 25 +/- 12%, and the labeling efficiency was 87 +/- 7%. Three hours after injection of labeled granulocytes and 2 hours after reperfusion, the grafts were harvested and cut into several segments for study of areas of anastomoses and midsections. On the basis of the radioactivity in the blood and in anastomotic and graft sections, the area of graft sections, and the neutrophilic granulocyte and differential leukocyte counts, the number of neutrophilic granulocytes adherent to a unit area and the total number of neutrophilic granulocytes on graft sections were calculated. These quantifications of the deposition of neutrophilic granulocytes indicated that the midsections of Gore-Tex grafts retained more neutrophilic granulocytes than did the midsections of vein grafts. Although the anastomotic areas retained more neutrophilic granulocytes than did the midsections of vein grafts, the opposite finding prevailed for the Gore-Tex grafts. A major fraction of neutrophilic granulocytes on Gore-Tex grafts was incorporated into the thrombus. Semiquantitative information obtained by scintigraphy of the deposition of neutrophilic granulocytes on vascular grafts also confirmed this observation

  18. FROM2D to 3d Supervised Segmentation and Classification for Cultural Heritage Applications

    Science.gov (United States)

    Grilli, E.; Dininno, D.; Petrucci, G.; Remondino, F.

    2018-05-01

    The digital management of architectural heritage information is still a complex problem, as a heritage object requires an integrated representation of various types of information in order to develop appropriate restoration or conservation strategies. Currently, there is extensive research focused on automatic procedures of segmentation and classification of 3D point clouds or meshes, which can accelerate the study of a monument and integrate it with heterogeneous information and attributes, useful to characterize and describe the surveyed object. The aim of this study is to propose an optimal, repeatable and reliable procedure to manage various types of 3D surveying data and associate them with heterogeneous information and attributes to characterize and describe the surveyed object. In particular, this paper presents an approach for classifying 3D heritage models, starting from the segmentation of their textures based on supervised machine learning methods. Experimental results run on three different case studies demonstrate that the proposed approach is effective and with many further potentials.

  19. Outcomes of AV Fistulas and AV Grafts after Interventional Stent-Graft Deployment in Haemodialysis Patients

    Energy Technology Data Exchange (ETDEWEB)

    Schmelter, Christopher, E-mail: christopher.schmelter@klinikum-ingolstadt.de; Raab, Udo, E-mail: udo.raab@klinikum-ingolstadt.de [Klinikum Ingolstadt, Department of Diagnostic and Interventional Radiology (Germany); Lazarus, Friedrich, E-mail: friedrich.lazarus@klinikum-ingolstadt.de [Klinikum Ingolstadt, Department of Nephrology (Germany); Ruppert, Volker, E-mail: volker.ruppert@klinikum-ingolstadt.de [Klinikum Ingolstadt, Department of Vascular Surgery (Germany); Vorwerk, Dierk, E-mail: dierk.vorwerk@klinikum-ingolstadt.de [Klinikum Ingolstadt, Department of Diagnostic and Interventional Radiology (Germany)

    2015-08-15

    PurposeThe study was designed to assess outcomes of arteriovenous (AV) accesses after interventional stent-graft deployment in haemodialysis patients.Materials and Methods63 haemodialysis patients with 66 AV fistulas and AV grafts were treated by interventional stent-graft deployment from 2006 to 2012 at our hospital. Data of these patients were retrospectively analysed for location of deployed stent-grafts, occurrence and location of (re-)stenosis and (re-)thrombosis. Complex stenosis was the most frequent indication for stent-graft deployment (45.5 %), followed by complications of angioplasty with vessel rupture or dissection (31.8 %).ResultsA high rate of procedural success was achieved (98.5 %). The most frequent location of the deployed stent-graft was the draining vein (66.7 %). Stent-graft deployment was more frequent in AV grafts than in AV fistulas. Primary patency was 45.5 % at 6 month, 31.3 % at 12 month and 19.2 % at 24 month. Primary patency was significantly better for AV fistulas than for AV grafts with deployed stent-grafts. Patency of the deployed stent-graft was much better than overall AV access primary patency with deployed stent-graft. Re-stenosis with thrombosis was the most frequent indication for re-intervention. Most frequent location of re-stenosis was the draining vein (37.1 %), followed by stenosis at the AV access (29.5 %) and the deployed stent-graft (23.5 %).ConclusionRe-stenosis and re-thrombosis remain frequent in AV fistulas and AV grafts in haemodialysis patients despite stent-graft deployment. Re-stenosis of the deployed stent-graft is, only in the minority of the cases, responsible for AV access dysfunction.

  20. Internal Prosthetic Replacement of Skeletal Segments Lost in Combat Injuries.

    Science.gov (United States)

    1973-08-31

    osteo- articular bone grafts. Clin. Ortho., 87: 156, 1972. 8. Tuli, S. M.: Bridging of bone defects by massive bone grafts in tumorous conditions. Clin...fashion in its proximal one-third to "prevent distractic ,n of the fragments. The fiber metal segment was then placed in the appropriate defect and the...defect slightly oversized and also osteotomizing the fibula to delete any possible distracting forces or angulating forces. The only complication in

  1. In vivo canine studies of a Sinkhole valve and vascular graft coated with biocompatible PU-PEO-SO3.

    Science.gov (United States)

    Han, D K; Lee, K B; Park, K D; Kim, C S; Jeong, S Y; Kim, Y H; Kim, H M; Min, B G

    1993-01-01

    PU-PEO-SO3 was applied as a coating material over a newly designed Sinkhole bileaflet PU heart valve and a porous PU vascular graft. Performance and biocompatibility were evaluated using an in vivo canine shunt system between the right ventricle and pulmonary artery. The survival periods in three implantations were 14, 24, and 39 days, during which no mechanical failure occurred in any Sinkhole valve or vascular graft. Scanning electron microscopy (SEM) studies demonstrated much less platelet adhesion and thrombus formation on PU-PEO-SO3 grafts than on PU vascular grafts. Cracks in the valve leaflet were occasionally observed on PU surfaces, but not on PU-PEO-SO3. After a 39 day implantation, calcium deposition on vascular grafts was decreased as compared with valve leaflets, and calcification on PU-PEO-SO3 was much lower than on PU. These results suggest that Sinkhole valves and vascular grafts are promising, and PU-PEO-SO3 as a coating material is more blood compatible, biostable, and calcification resistant in vivo than in untreated PU.

  2. Maxillary segmental distraction in children with unilateral clefts of lip, palate, and alveolus.

    Science.gov (United States)

    Zemann, Wolfgang; Pichelmayer, Margit

    2011-06-01

    Alveolar clefts are commonly closed by a bone grafting procedure. In cases of wide clefts the deficiency of soft tissue in the cleft area may lead to wound dehiscence and loss of the bony graft. Segmental maxillary bony transfer has been mentioned to be useful in such cases. Standard distraction devices allow unidirectional movement of the transported segment. Ideally the distraction should strictly follow the dental arch. The aim of this study was to analyze distraction devices that were adapted to the individual clinical situation of the patients. The goal was to achieve a distraction strictly parallel to the dental arch. Six children with unilateral clefts of lip, palate, and alveolus between 12 and 13 years of age were included in the study. The width of the cleft was between 7 and 19 mm. Dental cast models were used to manufacture individual distraction devices that should allow a segmental bony transport strictly parallel to the dental arch. Segmental osteotomy was performed under general anesthesia. Distraction was started 5 days after surgery. All distracters were tooth fixed but supported by palatal inserted orthodontic miniscrews. In all patients, a closure of the alveolar cleft was achieved. Two patients required additional bone grafting after the distraction procedure. The distraction was strictly parallel to the dental arch in all cases. In 1 case a slight cranial displacement of the transported maxillary segment could be noticed, leading to minor modifications of the following distractors. Distraction osteogenesis is a proper method to close wide alveolar clefts. Linear segmental transport is required in the posterior part of the dental arch, whereas in the frontal part the bony transport should run strictly parallel to the dental arch. An exact guided segmental transport may reduce the postoperative orthodontic complexity. Copyright © 2011 Mosby, Inc. All rights reserved.

  3. A Unified 3D Mesh Segmentation Framework Based on Markov Random Field

    OpenAIRE

    Z.F. Shi; L.Y. Lu; D. Le; X.M. Niu

    2012-01-01

    3D Mesh segmentation has become an important research field in computer graphics during the past decades. Many geometry based and semantic oriented approaches for 3D mesh segmentation has been presented. In this paper, we present a definition of mesh segmentation according to labeling problem. Inspired by the Markov Random Field (MRF) based image segmentation, we propose a new framework of 3D mesh segmentation based on MRF and use graph cuts to solve it. Any features of 3D mesh can be integra...

  4. New organophilic kaolin clays based on single-point grafted 3-aminopropyl dimethylethoxysilane.

    Science.gov (United States)

    Zaharia, A; Perrin, F-X; Teodorescu, M; Radu, A-L; Iordache, T-V; Florea, A-M; Donescu, D; Sarbu, A

    2015-10-14

    In this study, the organophilization procedure of kaolin rocks with a monofunctional ethoxysilane- 3 aminopropyl dimethyl ethoxysilane (APMS) is depicted for the first time. The two-step organophilization procedure, including dimethyl sulfoxide intercalation and APMS grafting onto the inner hydroxyl surface of kaolinite (the mineral) layers was tested for three sources of kaolin rocks (KR, KC and KD) with various morphologies and kaolinite compositions. The load of APMS in the kaolinite interlayer space was higher than that of 3-aminopropyl triethoxysilane (APTS) due to the single-point grafting nature of the organophilization reaction. A higher long-distance order of kaolinite layers with low staking was obtained for the APMS, due to a more controllable organiphilization reaction. Last but not least, the solid state (29)Si-NMR tests confirmed the single-point grafting mechanism of APMS, corroborating monodentate fixation on the kaolinite hydroxyl facets, with no contribution to the bidentate or tridentate fixation as observed for APTS.

  5. Comparative Efficacies of Collagen-Based 3D Printed PCL/PLGA/?-TCP Composite Block Bone Grafts and Biphasic Calcium Phosphate Bone Substitute for Bone Regeneration

    OpenAIRE

    Hwang, Kyoung-Sub; Choi, Jae-Won; Kim, Jae-Hun; Chung, Ho Yun; Jin, Songwan; Shim, Jin-Hyung; Yun, Won-Soo; Jeong, Chang-Mo; Huh, Jung-Bo

    2017-01-01

    The purpose of this study was to compare bone regeneration and space maintaining ability of three-dimensional (3D) printed bone grafts with conventional biphasic calcium phosphate (BCP). After mixing polycaprolactone (PCL), poly (lactic-co-glycolic acid) (PLGA), and ?-tricalcium phosphate (?-TCP) in a 4:4:2 ratio, PCL/PLGA/?-TCP particulate bone grafts were fabricated using 3D printing technology. Fabricated particulate bone grafts were mixed with atelocollagen to produce collagen-based PCL/P...

  6. Grafting of 2 (2-hydroxy-5-vinylphenyl) 2H-benzotriazole onto polymers with aliphatic groups. Synthesis and polymerization of 2 (2-hydroxy-5-isopropenylphenyl) 2H-benzotriazole and a new synthesis of 2 (2-hydroxy-5-vinylphenyl) 2H-benzotriazole

    Science.gov (United States)

    Pradellok, W.; Nir, Z.; Vogl, O.

    1981-01-01

    Successful grafting of 2(2-hydroxy-5-vinylphenyl)2H-benzotriazole onto saturated aliphatic C-H groups of polymers has been accomplished. When the grafting reaction was carried out in chlorobenzene at 150 C = 160 C with di-tertiarybutylperoxide as the grafting initiator, grafts as high as 20 percent - 30 percent at a grafting efficiency of 50 percent and 80 percent have readily been obtained. The grafting reaction was carried out in tubes sealed under high vacuum since trace amounts of oxygen cause complete inhibition of the grafting reaction by the phenolic monomer. On a variety of different polymers including atactic polypropylene, ethylene/vinyl acetate copolymer, poly(methyl methacrylate), poly(butyl acrylate), and polycarbonate were used.

  7. Synthesis, Characterization, and Aqueous Lubricating Properties of Amphiphilic Graft Copolymers Comprising 2-Methoxyethyl Acrylate

    DEFF Research Database (Denmark)

    Javakhishvili, Irakli; Røn, Troels; Jankova Atanasova, Katja

    2014-01-01

    Amphiphilic anionic and cationic graft copolymers possessing poly(2-hydroxyethyl methacrylate) (PHEMA) backbone and poly(methacrylic acid), poly(2-methoxyethyl acrylate-co-methacrylic acid), and poly(2-methoxyethyl acrylate-co-2-(dimethylamino)ethyl methacrylate) grafts are constructed by merging...... of the corresponding monomers followed by deblocking reaction leads to well-defined amphiphiles with narrow molecular weight distributions (PDI ≤ 1.29) and varying content of methacrylic acid. The graft copolymers showed effective surface adsorption and lubrication for self-mated poly(dimethylsiloxane) (PDMS) contacts...

  8. Crystallization of calcium carbonate on radiation-grafted polyethylene films

    International Nuclear Information System (INIS)

    Hou Zhengchi; Zhang Fengying; Deng Bo; Yang Haijun; Chen Shuang; Sheng Kanglong

    2006-01-01

    In biomineralization processes, nucleation and growth of inorganic crystals can be regulated by organic template molecules. This has inspired great interest in studying mimic biomineralization. In our study, growing CaCO 3 crystals on PE films functionalized through radiation-induced grafting was attempted. PE films grafted with different functional groups of different distributions and densities were used as substrates for CaCO 3 nucleation and crystal growth from Ca(HCO 3 ) 2 supersaturated solution under different environmental conditions (e.g. additives and temperature) to study the effects and mechanisms. The grafted PE films were analyzed by ATR-FTIR and AFM, and the evolution of CaCO 3 crystal formation on the grafted PE film was characterized by SEM, FTIR, and XRD. The results indicated that heterogeneous nucleation of CaCO 3 crystals was significantly facilitated by the functional groups grafted on the surface of PE films, that the morphology of CaCO 3 crystals could be controlled by distribution and density of the grafted functional groups, and that polymorphism of CaCO 3 crystal could be regulated by selection of grafting functional groups. We believe that studying the effects of chemical structures on inorganic crystallization is of great importance since radiation-induced grafting is an effective method to graft desirable functional groups onto different polymers by selected monomers, in the endeavor of developing advanced organic/inorganic composites with high performance, with a wide availability of polymers, monomers and inorganic solutions. (authors)

  9. Spatio-Temporal Video Object Segmentation via Scale-Adaptive 3D Structure Tensor

    Directory of Open Access Journals (Sweden)

    Hai-Yun Wang

    2004-06-01

    Full Text Available To address multiple motions and deformable objects' motions encountered in existing region-based approaches, an automatic video object (VO segmentation methodology is proposed in this paper by exploiting the duality of image segmentation and motion estimation such that spatial and temporal information could assist each other to jointly yield much improved segmentation results. The key novelties of our method are (1 scale-adaptive tensor computation, (2 spatial-constrained motion mask generation without invoking dense motion-field computation, (3 rigidity analysis, (4 motion mask generation and selection, and (5 motion-constrained spatial region merging. Experimental results demonstrate that these novelties jointly contribute much more accurate VO segmentation both in spatial and temporal domains.

  10. Diffusion tensor imaging of the anterior cruciate ligament graft.

    Science.gov (United States)

    Van Dyck, Pieter; Froeling, Martijn; De Smet, Eline; Pullens, Pim; Torfs, Michaël; Verdonk, Peter; Sijbers, Jan; Parizel, Paul M; Jeurissen, Ben

    2017-11-01

    A great need exists for objective biomarkers to assess graft healing following ACL reconstruction to guide the time of return to sports. The purpose of this study was to evaluate the feasibility and reliability of diffusion tensor imaging (DTI) to delineate the anterior cruciate ligament (ACL) graft and to investigate its diffusion properties using a clinical 3T scanner. DTI of the knee (b = 0, 400, and 800 s/mm 2 , 10 diffusion directions, repeated 16 times for a total of 336 diffusion-weighted volumes) was performed at 3T in 17 patients between 3 and 7 months (mean, 4 months) following ACL reconstruction. Tractography was performed by two independent observers to delineate the ACL graft. Fractional anisotropy (FA), mean diffusivity (MD), axial diffusivity (AD), and radial diffusivity (RD) were calculated within the graft. Interrater reliability was assessed using the intraclass correlation coefficient (ICC) and the scan-rescan reproducibility was evaluated based on the percentage coefficient of variance (%CV) across 20 repetition bootknife samples. In all subjects, tractography of the ACL graft was feasible. Quantitative evaluation of the diffusion properties of the ACL graft yielded the following mean ± SD values: FA = 0.23 ± 0.04; MD = 1.30 ± 0.11 × 10 -3 mm 2 /s; AD = 1.61 ± 0.12 × 10 -3 mm 2 /s, and RD = 1.15 ± 0.11 × 10 -3 mm 2 /s. Interrater reliability for the DTI parameters was excellent (ICC = 0.91-0.98). Mean %CVs for FA, MD, AD, and RD were 4.6%, 3.5%, 3.7%, and 4.4%, respectively. We demonstrated the feasibility and reliability of DTI for the visualization and quantitative evaluation of the ACL graft at 3T. 3 Technical Efficacy: Stage 1 J. Magn. Reson. Imaging 2017;46:1423-1432. © 2017 International Society for Magnetic Resonance in Medicine.

  11. Do stress fractures induce hypertrophy of the grafted fibula? A report of three cases received free vascularized fibular graft treatment for tibial defects.

    Science.gov (United States)

    Qi, Yong; Sun, Hong-Tao; Fan, Yue-Guang; Li, Fei-Meng; Lin, Zhou-Sheng

    2016-06-01

    The presence of large segmental defects of the diaphyseal bone is challenging for orthopedic surgeons. Free vascularized fibular grafting (FVFG) is considered to be a reliable reconstructive procedure. Stress fractures are a common complication following this surgery, and hypertrophy is the main physiological change of the grafted fibula. The exact mechanism of hypertrophy is not completely known. To the best of our knowledge, no studies have examined the possible relationship between stress fractures and hypertrophy. We herein report three cases of patients underwent FVFG. Two of them developed stress fractures and significant hypertrophy, while the remaining patient developed neither stress fractures nor significant hypertrophy. This phenomenon indicates that a relationship may exist between stress fractures and hypertrophy of the grafted fibula, specifically, that the presence of a stress fracture may initiate the process of hypertrophy.

  12. Preliminary study of coconut water for graft tissues preservation in transplantation

    Directory of Open Access Journals (Sweden)

    Jorge Miguel Schettino César

    Full Text Available OBJECTIVE: to verify the effectiveness of coconut water in preserving tissues for transplant. METHODS: Fifty male Wistar rats were randomly distributed in five groups, according to the following preservation solutions for tissue grafts: Group 1: Lactated Ringer; Group 2: Belzer solution; Group 3: mature coconut water; Group 4: green coconut water; Group 5: modified coconut water. In Group 5, the green coconut water has been modified like the Belzer solution. From each animal we harvasted the spleen, ovaries and skin of the back segment. These tissues were preserved for six hours in one of the solutions. Then, the grafts were reimplanted. The recovery of the function of the implanted tissues was assessed 90 days after surgery, by splenic scintigraphy and blood exame. The implanted tissues were collected for histopathological examination. RESULTS: The serum levels did not differ among groups, except for the animals in Group 5, which showed higher levels of IgG than Group 1, and differences in relation to FSH between groups 1 and 2 (p <0.001, 4 and 2 (p = 0.03 and 5 and 2 (p = 0.01. The splenic scintigraphy was not different between groups. The ovarian tissue was better preserved in mature coconut water (p <0.007. CONCLUSION: the coconut water-based solutions preserves spleen, ovary, and rat skin for six hours, maintaining their normal function.

  13. Xeno-free culture of human pluripotent stem cells on oligopeptide-grafted hydrogels with various molecular designs

    Science.gov (United States)

    Chen, Yen-Ming; Chen, Li-Hua; Li, Meng-Pei; Li, Hsing-Fen; Higuchi, Akon; Kumar, S. Suresh; Ling, Qing-Dong; Alarfaj, Abdullah A.; Munusamy, Murugan A.; Chang, Yung; Benelli, Giovanni; Murugan, Kadarkarai; Umezawa, Akihiro

    2017-01-01

    Establishing cultures of human embryonic (ES) and induced pluripotent (iPS) stem cells in xeno-free conditions is essential for producing clinical-grade cells. Development of cell culture biomaterials for human ES and iPS cells is critical for this purpose. We designed several structures of oligopeptide-grafted poly (vinyl alcohol-co-itaconic acid) hydrogels with optimal elasticity, and prepared them in formations of single chain, single chain with joint segment, dual chain with joint segment, and branched-type chain. Oligopeptide sequences were selected from integrin- and glycosaminoglycan-binding domains of the extracellular matrix. The hydrogels grafted with vitronectin-derived oligopeptides having a joint segment or a dual chain, which has a storage modulus of 25 kPa, supported the long-term culture of human ES and iPS cells for over 10 passages. The dual chain and/or joint segment with cell adhesion molecules on the hydrogels facilitated the proliferation and pluripotency of human ES and iPS cells. PMID:28332572

  14. Single-segment and double-segment INTACS for post-LASIK ectasia.

    Directory of Open Access Journals (Sweden)

    Hassan Hashemi

    2014-09-01

    Full Text Available The objective of the present study was to compare single segment and double segment INTACS rings in the treatment of post-LASIK ectasia. In this interventional study, 26 eyes with post-LASIK ectasia were assessed. Ectasia was defined as progressive myopia regardless of astigmatism, along with topographic evidence of inferior steepening of the cornea after LASIK. We excluded those with a history of intraocular surgery, certain eye conditions, and immune disorders, as well as monocular, pregnant and lactating patients. A total of 11 eyes had double ring and 15 eyes had single ring implantation. Visual and refractive outcomes were compared with preoperative values based on the number of implanted INTACS rings. Pre and postoperative spherical equivalent were -3.92 and -2.29 diopter (P=0.007. The spherical equivalent decreased by 1 ± 3.2 diopter in the single-segment group and 2.56 ± 1.58 diopter in the double-segment group (P=0.165. Mean preoperative astigmatism was 2.38 ± 1.93 diopter which decreased to 2.14 ± 1.1 diopter after surgery (P=0.508; 0.87 ± 1.98 diopter decrease in the single-segment group and 0.67 ± 1.2 diopter increase in the double-segment group (P=0.025. Nineteen patients (75% gained one or two lines, and only three, who were all in the double-segment group, lost one or two lines of best corrected visual acuity. The spherical equivalent and vision significantly decreased in all patients. In these post-LASIK ectasia patients, the spherical equivalent was corrected better with two segments compared to single segment implantation; nonetheless, the level of astigmatism in the single-segment group was significantly better than that in the double-segment group.

  15. Needle segmentation using 3D Hough transform in 3D TRUS guided prostate transperineal therapy

    Energy Technology Data Exchange (ETDEWEB)

    Qiu Wu [Department of Biomedical Engineering, School of Life Science and Technology, Huazhong University of Science and Technology, Wuhan, Hubei 430074 (China); Imaging Research Laboratories, Robarts Research Institute, Western University, London, Ontario N6A 5K8 (Canada); Yuchi Ming; Ding Mingyue [Department of Biomedical Engineering, School of Life Science and Technology, Huazhong University of Science and Technology, Wuhan, Hubei 430074 (China); Tessier, David; Fenster, Aaron [Imaging Research Laboratories, Robarts Research Institute, University of Western Ontario, London, Ontario N6A 5K8 (Canada)

    2013-04-15

    Purpose: Prostate adenocarcinoma is the most common noncutaneous malignancy in American men with over 200 000 new cases diagnosed each year. Prostate interventional therapy, such as cryotherapy and brachytherapy, is an effective treatment for prostate cancer. Its success relies on the correct needle implant position. This paper proposes a robust and efficient needle segmentation method, which acts as an aid to localize the needle in three-dimensional (3D) transrectal ultrasound (TRUS) guided prostate therapy. Methods: The procedure of locating the needle in a 3D TRUS image is a three-step process. First, the original 3D ultrasound image containing a needle is cropped; the cropped image is then converted to a binary format based on its histogram. Second, a 3D Hough transform based needle segmentation method is applied to the 3D binary image in order to locate the needle axis. The position of the needle endpoint is finally determined by an optimal threshold based analysis of the intensity probability distribution. The overall efficiency is improved through implementing a coarse-fine searching strategy. The proposed method was validated in tissue-mimicking agar phantoms, chicken breast phantoms, and 3D TRUS patient images from prostate brachytherapy and cryotherapy procedures by comparison to the manual segmentation. The robustness of the proposed approach was tested by means of varying parameters such as needle insertion angle, needle insertion length, binarization threshold level, and cropping size. Results: The validation results indicate that the proposed Hough transform based method is accurate and robust, with an achieved endpoint localization accuracy of 0.5 mm for agar phantom images, 0.7 mm for chicken breast phantom images, and 1 mm for in vivo patient cryotherapy and brachytherapy images. The mean execution time of needle segmentation algorithm was 2 s for a 3D TRUS image with size of 264 Multiplication-Sign 376 Multiplication-Sign 630 voxels. Conclusions

  16. Needle segmentation using 3D Hough transform in 3D TRUS guided prostate transperineal therapy

    International Nuclear Information System (INIS)

    Qiu Wu; Yuchi Ming; Ding Mingyue; Tessier, David; Fenster, Aaron

    2013-01-01

    Purpose: Prostate adenocarcinoma is the most common noncutaneous malignancy in American men with over 200 000 new cases diagnosed each year. Prostate interventional therapy, such as cryotherapy and brachytherapy, is an effective treatment for prostate cancer. Its success relies on the correct needle implant position. This paper proposes a robust and efficient needle segmentation method, which acts as an aid to localize the needle in three-dimensional (3D) transrectal ultrasound (TRUS) guided prostate therapy. Methods: The procedure of locating the needle in a 3D TRUS image is a three-step process. First, the original 3D ultrasound image containing a needle is cropped; the cropped image is then converted to a binary format based on its histogram. Second, a 3D Hough transform based needle segmentation method is applied to the 3D binary image in order to locate the needle axis. The position of the needle endpoint is finally determined by an optimal threshold based analysis of the intensity probability distribution. The overall efficiency is improved through implementing a coarse-fine searching strategy. The proposed method was validated in tissue-mimicking agar phantoms, chicken breast phantoms, and 3D TRUS patient images from prostate brachytherapy and cryotherapy procedures by comparison to the manual segmentation. The robustness of the proposed approach was tested by means of varying parameters such as needle insertion angle, needle insertion length, binarization threshold level, and cropping size. Results: The validation results indicate that the proposed Hough transform based method is accurate and robust, with an achieved endpoint localization accuracy of 0.5 mm for agar phantom images, 0.7 mm for chicken breast phantom images, and 1 mm for in vivo patient cryotherapy and brachytherapy images. The mean execution time of needle segmentation algorithm was 2 s for a 3D TRUS image with size of 264 × 376 × 630 voxels. Conclusions: The proposed needle segmentation

  17. Surface modification of TiO2 nanotubes by grafting with APTS coupling agents

    Science.gov (United States)

    Phan Duong, Hong; Le, Minh Duc; Dao, Hung Cuong; Chen, Chia-Yun

    2017-10-01

    Titanium dioxide nanotubes (TNTs) have been considered the promising nanostructures employed for many practical applications such as biomedical, photonic and optoelectronic devices. Nevertheless, strong aggregation of TNTs within various aqueous media significantly hindered their practical utilizations and the capability of dispersing TNTs in the desired solvents are urgent to be improved. Therefore, in this study, the methodic investigations have been performed on the grafted modification of 3-aminopropyl triethoxysilane (APTS) on the surfaces of synthesized TNTs. A preliminary study was carried out to evaluate the influences of key parameters, including the concentrations of coupling agents, temperatures and the reaction durations, on the grafting efficiency of the aminosilane using Statistical design of experiments (DoE) methodology. TNTs with approximately 10-20 nm in diameter were prepared with the controlled hydrothermal treatment of commercialized P25 particles. The obtained products were revealed by the modern physicochemical systems including x-ray diffraction (XRD), transmission electron microscopy (TEM) and Brunauer-Emmett-Teller (BET) analysis. The additions of silane agent, reaction temperature and time have been adjusted to reveal the influences of the grafting efficiency (from 2.5 to 7.8 wt %) by thermal gravimetric analysis (TGA). Analysis of Fourier transform infrared spectroscopy (FTIR) has confirmed the successful link of Ti-O-Si chemical bonds on the grafted TNTs.

  18. Grafting poly ethylene glycol chains for antifouling purposes using supercritical CO2

    DEFF Research Database (Denmark)

    Lokanathan, Arcot R.

    2011-01-01

    solvent in processes involving PEG grafting for antifouling purposes. Significant chemical efficiency and extremely low surface tension makes scCO2 an apt solvent for Grafting PEG brushes into three dimensional micro or nano porous scaffolds related to tissue engineering. References: 1. Peter Kingshott...

  19. Grafting and Poisson Structure in (2+1)-Gravity with Vanishing Cosmological Constant

    Science.gov (United States)

    Meusburger, C.

    2006-09-01

    We relate the geometrical construction of (2+1)-spacetimes via grafting to phase space and Poisson structure in the Chern-Simons formulation of (2+1)-dimensional gravity with vanishing cosmological constant on manifolds of topology mathbb{R} × S_g, where S g is an orientable two-surface of genus g>1. We show how grafting along simple closed geodesics λ is implemented in the Chern-Simons formalism and derive explicit expressions for its action on the holonomies of general closed curves on S g .We prove that this action is generated via the Poisson bracket by a gauge invariant observable associated to the holonomy of λ. We deduce a symmetry relation between the Poisson brackets of observables associated to the Lorentz and translational components of the holonomies of general closed curves on S g and discuss its physical interpretation. Finally, we relate the action of grafting on the phase space to the action of Dehn twists and show that grafting can be viewed as a Dehn twist with a formal parameter θ satisfying θ2 = 0.

  20. Mesenchymal stem cells improve mouse non-heart-beating liver graft survival by inhibiting Kupffer cell apoptosis via TLR4-ERK1/2-Fas/FasL-caspase3 pathway regulation

    Directory of Open Access Journals (Sweden)

    Yang Tian

    2016-10-01

    Full Text Available Abstract Background Liver transplantation is the optimal treatment option for end-stage liver disease, but organ shortages dramatically restrict its application. Donation after cardiac death (DCD is an alternative approach that may expand the donor pool, but it faces challenges such as graft dysfunction, early graft loss, and cholangiopathy. Moreover, DCD liver grafts are no longer eligible for transplantation after their warm ischaemic time exceeds 30 min. Mesenchymal stem cells (MSCs have been proposed as a promising therapy for treatment of certain liver diseases, but the role of MSCs in DCD liver graft function remains elusive. Methods In this study, we established an arterialized mouse non-heart-beating (NHB liver transplantation model, and compared survival rates, cytokine and chemokine expression, histology, and the results of in vitro co-culture experiments in animals with or without MSC infusion. Results MSCs markedly ameliorated NHB liver graft injury and improved survival post-transplantation. Additionally, MSCs suppressed Kupffer cell apoptosis, Th1/Th17 immune responses, chemokine expression, and inflammatory cell infiltration. In vitro, PGE2 secreted by MSCs inhibited Kupffer cell apoptosis via TLR4-ERK1/2-caspase3 pathway regulation. Conclusion Our study uncovers a protective role for MSCs and elucidates the underlying immunomodulatory mechanism in an NHB liver transplantation model. Our results suggest that MSCs are uniquely positioned for use in future clinical studies owing to their ability to protect DCD liver grafts, particularly in patients for whom DCD organs are not an option according to current criteria.

  1. Design and synthesis of an amphiphilic graft hydrogel having a hydrophobic domain formed by multiple interactions

    Energy Technology Data Exchange (ETDEWEB)

    Nitta, Kyohei [Department of Life and Functional Material Science, Graduate School of Natural Science, Konan University, 8-9-1 Okamoto, Higashinada, Kobe 658-8501 (Japan); Japan Society for the Promotion of Science (DC1), Ichibancho, Chiyoda, Tokyo 102-8471 (Japan); Kimoto, Atsushi [Department of Chemistry of Functional Molecules, Faculty of Science and Engineering, Konan University, 8-9-1 Okamoto, Higashinada, Kobe 658-8501 (Japan); Watanabe, Junji, E-mail: junjiknd@konan-u.ac.jp [Department of Chemistry of Functional Molecules, Faculty of Science and Engineering, Konan University, 8-9-1 Okamoto, Higashinada, Kobe 658-8501 (Japan)

    2016-11-01

    A novel hydrogel having hydrophobic oligo segments and hydrophilic poly(acrylamidoglycolic acid) (PAGA) as pH responsive polymer segments was designed and synthesized to be used as a soft biomaterial. Poly(trimethylene carbonate) (PTMC) as the side chain, for which the degrees of polymerization were 9, 19, and 49, and the composition ratios were 1, 5, and 10 mol%, was used as the oligo segment in the hydrogel. The swelling ratio of the hydrogel was investigated under various changes in conditions such as pH, temperature, and hydrogen bonding upon urea addition. Under pH 2–11 conditions, the graft gel reversibly swelled and shrank due to the effect of PAGA main chain. The interior morphology and skin layer of the hydrogel was observed by a scanning electron microscope. The hydrogel composed of PAGA as the hydrophilic polymer backbone had a sponge-like structure, with a pore size of approximately 100 μm. On the other hand, upon increasing the ratio of trimethylene carbonate (TMC) units in the hydrogel, the pores became smaller or disappeared. Moreover, thickness of the skin layer significantly increased with the swelling ratio depended on the incorporation ratios of the PTMC macromonomer. Molecular incorporation in the hydrogel was evaluated using a dye as a model drug molecule. These features would play an important role in drug loading. Increasing the ratio of TMC units favored the adsorption of the dye and activation of the incorporation behavior. - Highlights: • Hydrogen bonding and hydrophobic interaction are dominant factor for forming hydrogels. • Hydrogel properties were tuned by changing in graft length and macromonomer content in feed. • The resulting graft gel could encapsulate and retain organic dye in the hydrogel. • Poly(trimethylene carbonate) segment in the hydrogel was dominant unit for hydrogel.

  2. Design and synthesis of an amphiphilic graft hydrogel having a hydrophobic domain formed by multiple interactions

    International Nuclear Information System (INIS)

    Nitta, Kyohei; Kimoto, Atsushi; Watanabe, Junji

    2016-01-01

    A novel hydrogel having hydrophobic oligo segments and hydrophilic poly(acrylamidoglycolic acid) (PAGA) as pH responsive polymer segments was designed and synthesized to be used as a soft biomaterial. Poly(trimethylene carbonate) (PTMC) as the side chain, for which the degrees of polymerization were 9, 19, and 49, and the composition ratios were 1, 5, and 10 mol%, was used as the oligo segment in the hydrogel. The swelling ratio of the hydrogel was investigated under various changes in conditions such as pH, temperature, and hydrogen bonding upon urea addition. Under pH 2–11 conditions, the graft gel reversibly swelled and shrank due to the effect of PAGA main chain. The interior morphology and skin layer of the hydrogel was observed by a scanning electron microscope. The hydrogel composed of PAGA as the hydrophilic polymer backbone had a sponge-like structure, with a pore size of approximately 100 μm. On the other hand, upon increasing the ratio of trimethylene carbonate (TMC) units in the hydrogel, the pores became smaller or disappeared. Moreover, thickness of the skin layer significantly increased with the swelling ratio depended on the incorporation ratios of the PTMC macromonomer. Molecular incorporation in the hydrogel was evaluated using a dye as a model drug molecule. These features would play an important role in drug loading. Increasing the ratio of TMC units favored the adsorption of the dye and activation of the incorporation behavior. - Highlights: • Hydrogen bonding and hydrophobic interaction are dominant factor for forming hydrogels. • Hydrogel properties were tuned by changing in graft length and macromonomer content in feed. • The resulting graft gel could encapsulate and retain organic dye in the hydrogel. • Poly(trimethylene carbonate) segment in the hydrogel was dominant unit for hydrogel.

  3. Effect of scopoletin on fascia-wrapped diced cartilage grafts | Zeng ...

    African Journals Online (AJOL)

    Purpose: To evaluate the effect of scopoletin (SL) on fascia-wrapped diced cartilage grafts in rhinoplasty surgery. Methods: Cartilage grafts (2 × 2 cm) from the ears of New Zealand rabbits were diced into sections (1 mm3) and then wrapped in muscle fascia taken from the right rear leg. Each graft was placed on the back of ...

  4. Research on simulation calculation method of biomechanical characteristics of C1-3 motion segment damage mechanism

    Directory of Open Access Journals (Sweden)

    HUANG Ju-ying

    2013-11-01

    Full Text Available Objective To develop the finite element model (FEM of cervical spinal C1-3 motion segment, and to make biomechanical finite element analysis (FEA on C1-3 motion segment and thus simulate the biomechanical characteristics of C1-3 motion segment in distraction violence, compression violence, hyperextension violence and hyperflexion violence. Methods According to CT radiological data of a healthy adult, the vertebrae and intervertebral discs of cervical spinal C1-3 motion segment were respectively reconstructed by Mimics 10.01 software and Geomagic 10.0 software. The FEM of C1-3 motion segment was reconstructed by attaching the corresponding material properties of cervical spine in Ansys software. The biomechanical characteristics of cervical spinal C1-3 motion segment model were simulated under the 4 loadings of distraction violence, compression violence, hyperextension violence and hyperflexion violence by finite element method. Results In the loading of longitudinal stretch, the stress was relatively concentrated in the anterior arch of atlas, atlantoaxial joint and C3 lamina and spinous process. In the longitudinal compressive loads, the maximum stress of the upper cervical spine was located in the anterior arch of atlas. In the loading of hyperextension moment, the stress was larger in the massa lateralis atlantis, the lateral and posterior arch junction of atlas, the posterior arch nodules of the atlas, superior articular surface of axis and C2 isthmus. In the loading of hyperflexion moment, the stress was relatively concentrated in the odontoid process of axis, the posterior arch of atlas, the posterior arch nodules of atlas, C2 isthmic and C2 inferior articular process. Conclusion Finite element biomechanical testing of C1-3 motion segment can predict the biomechanical mechanism of upper cervical spine injury.

  5. Changes in histopathology and cytokeratin AE1/AE3 expression in skin graft with different time on Indonesian local cats.

    Science.gov (United States)

    Erwin; Etriwati; Gunanti; Handharyani, Ekowati; Noviana, Deni

    2017-06-01

    A good skin graft histopathology is followed by formation of hair follicle, sweat gland, sebaceous gland, blood vessel, lightly dense connective tissue, epidermis, and dermis layer. This research aimed to observe histopathology feature and cytokeratin AE1/AE3 expression on cat skin post skin grafting within a different period of time. Nine male Indonesian local cats aged 1-2 years old weighing 3-4 kg were separated into three groups. First surgery created defect wound of 2 cm × 2 cm in size to whole groups. The wounds were left alone for several days, differing in interval between each group, respectively: Group I (for 2 days), Group II (for 4 days), and Group III (for 6 days). The second surgery was done to each group which harvested skin of thoracic area and applied it on recipient wound bed. On day 24 th post skin graft was an examination of histopathology and cytokeratin AE1/AE3 immunohistochemistry. Group I donor skin's epidermis layer had not formed completely whereas epidermis of donor skin of Groups II and III had completely formed. In all group hair follicle, sweat gland, sebaceous gland, and neovascularization were found. The density of connective tissue in Group I was very solid than other groups. Cytokeratin AE1/AE3 expression was found on donor skin's epithelial cell in epidermis and dermis layer with very brown intensity for Group II, brown intensity for Group II, and lightly brown for Group I. Histopathological structure and cytokeratin AE1/AE3 expression post skin graft are better in Groups II and III compared to Group I.

  6. Does pretransplant soluble CD30 serum concentration affect deceased-donor kidney graft function 3 years after transplantation?

    Science.gov (United States)

    Kovac, J; Arnol, M; Vidan-Jeras, B; Bren, A F; Kandus, A

    2008-06-01

    Elevated serum concentrations of soluble CD30 molecule (sCD30) have been related to acute cellular rejection and poor graft outcomes in kidney transplantation. This historical cohort study investigated the association of pretransplant sCD30 serum concentrations with kidney graft function expressed as estimated glomerular filtration rate (GFR) at 3 years after transplantation. Pretransplant sera from 176 adult deceased-donor kidney graft recipients were tested for sCD30 content using a commercially available automated enzyme-linked immunosorbent assay. The immunosuppression consisted of induction therapy with monoclonal anti-CD25 antibodies and a maintenance regimen of cyclosporine (CsA)-based therapy. GFR was estimated (eGFR) by the four-variable Modification of Diet in Renal Disease (MDRD) Study equation. According to the distribution of pretransplant sCD30 levels (median 66.7 U/mL; interquartile range, 46.6 to 98.6 U/mL), a concentration of 66 U/mL or higher was defined as high (n = 89) and below 66 U/mL as low (n = 87). Three years after transplantation, eGFR was not significantly different among recipients in high versus low sCD30 groups (69 +/- 23 mL/min/1.73m2 vs 66 +/- 21 mL/min/1.73m2; P = .327) and there was no correlation between eGFR and pretransplant sCD30 levels (r2 = 0.001; P = .73). Upon multivariate regression analysis, donor age, recipient body mass index at transplantation, and acute rejection episodes were independent variables affecting eGFR at 3 years after transplantation. This study showed that pretransplant sCD30 serum concentrations were not associated with deceased-donor kidney graft function at 3 years after transplantation. The immunosuppression with anti-CD25 antibodies and a triple CsA-based maintenance regimen could possibly be decisive for our findings.

  7. 3D Building Models Segmentation Based on K-Means++ Cluster Analysis

    Science.gov (United States)

    Zhang, C.; Mao, B.

    2016-10-01

    3D mesh model segmentation is drawing increasing attentions from digital geometry processing field in recent years. The original 3D mesh model need to be divided into separate meaningful parts or surface patches based on certain standards to support reconstruction, compressing, texture mapping, model retrieval and etc. Therefore, segmentation is a key problem for 3D mesh model segmentation. In this paper, we propose a method to segment Collada (a type of mesh model) 3D building models into meaningful parts using cluster analysis. Common clustering methods segment 3D mesh models by K-means, whose performance heavily depends on randomized initial seed points (i.e., centroid) and different randomized centroid can get quite different results. Therefore, we improved the existing method and used K-means++ clustering algorithm to solve this problem. Our experiments show that K-means++ improves both the speed and the accuracy of K-means, and achieve good and meaningful results.

  8. 3D BUILDING MODELS SEGMENTATION BASED ON K-MEANS++ CLUSTER ANALYSIS

    Directory of Open Access Journals (Sweden)

    C. Zhang

    2016-10-01

    Full Text Available 3D mesh model segmentation is drawing increasing attentions from digital geometry processing field in recent years. The original 3D mesh model need to be divided into separate meaningful parts or surface patches based on certain standards to support reconstruction, compressing, texture mapping, model retrieval and etc. Therefore, segmentation is a key problem for 3D mesh model segmentation. In this paper, we propose a method to segment Collada (a type of mesh model 3D building models into meaningful parts using cluster analysis. Common clustering methods segment 3D mesh models by K-means, whose performance heavily depends on randomized initial seed points (i.e., centroid and different randomized centroid can get quite different results. Therefore, we improved the existing method and used K-means++ clustering algorithm to solve this problem. Our experiments show that K-means++ improves both the speed and the accuracy of K-means, and achieve good and meaningful results.

  9. Graft union formation in artichoke grafting onto wild and cultivated cardoon: an anatomical study.

    Science.gov (United States)

    Trinchera, Alessandra; Pandozy, Gianmarco; Rinaldi, Simona; Crinò, Paola; Temperini, Olindo; Rea, Elvira

    2013-12-15

    In order to develop a non-chemical method such as grafting effective against well-known artichoke soil borne diseases, an anatomical study of union formation in artichoke grafted onto selected wild and cultivated cardoon rootstocks, both resistant to Verticillium wilt, was performed. The cardoon accessions Belgio (cultivated cardoon) and Sardo (wild cardoon) were selected as rootstocks for grafting combinations with the artichoke cv. Romolo. Grafting experiments were carried out in the autumn and spring. The anatomical investigation of grafting union formation was conducted by scanning electron microscopy (SEM) on the grafting portions at the 3rd, 6th, 10th, 12th day after grafting. For the autumn experiment only, SEM analysis was also performed at 30 d after grafting. A high affinity between artichoke scion and cardoon rootstocks was observed, with some genotype differences in healing time between the two bionts. SEM images of scion/rootstock longitudinal sections revealed the appearance of many interconnecting structures between the two grafting components just 3d after grafting, followed by a vascular rearrangement and a callus development during graft union formation. De novo formation of many plasmodesmata between scion and rootstock confirmed their high compatibility, particularly in the globe artichoke/wild cardoon combination. Moreover, the duration of the early-stage grafting process could be influenced not only by the scion/rootstock compatibility, but also by the seasonal conditions, being favored by lower temperatures and a reduced light/dark photoperiod. Copyright © 2013 Elsevier GmbH. All rights reserved.

  10. Kinetics Study of Silver Electrocrystallization on (3-mercaptopropyl)trimethoxysilane-grafted Indium Tin Oxide Plastic Substrate

    International Nuclear Information System (INIS)

    Hau, Nga Yu; Chang, Ya-Huei; Feng, Shien-Ping

    2015-01-01

    Highlights: • The larger charge transfer coefficient supports that MPS promotes electrodeposition. • ACV shows that electron-transfer rate enhanced by 2.5 times after MPS treatment. • The fitting of CA defined the Ag nucleation mode on blank and MPS-grafted ITO-PEN. • MPS treatment changed the nucleation mode from 2-step to a single step one. - Abstract: 3-mercaptopropyl-trimethoxysilane (MPS) self-assembled monolayer (SAM) has been demonstrated as effective promoters to enable direct electroplated metallization on indium tin oxide (ITO) plastic substrate. In this paper, the detail kinetics in Ag electrocrystallization on MPS-grafted ITO-PEN is reported. Contact angle measurement provides evidence of bridging-link effect between the sulfur head groups of MPS and the Ag + ions in the electrolyte. Electrochemical techniques including cyclic voltammetry and Tafel plot were used to investigate the redox kinetics. Quantitative evaluation was conducted by alternating current voltammetry to determine the rate constant of electron transfer. The chronoamperograms and their fitting results suggest a combined model with two-dimensional/three-dimensional nucleation transition and Shariker-Hills model for electroplated Ag on blank ITO-PEN and MPS-grafted ITO-PEN respectively

  11. Sorption of europium (3) by polymer sorbents with grafted heterocyclic nitrogen-containing groupings

    International Nuclear Information System (INIS)

    Bel'tyukova, S.V.; Kravchenko, T.B.; Balamtsarashvili, G.M.; Roska, A.S.

    1990-01-01

    On polymer sorbents (copolymer of styrene-divinylbenzene) with grafted heterocyclic nitrogen-containing functional groupings of tetrazole, triazole and imidazole (sorbents 1,2,3, respectively). It is stated that europium sorption takes place from neutral solutions in presence of organic solvents. Luminescent properties of europium on sorbent are used to develope methods of its determination in high purity lanthanide and yttrium oxides. Europium determination limits consist 7.5·10 -5 μg/ml on 1 and 3 sorbents and 1.5·10 -4 μg/ml on sorbent 2, S p value is 0.089 and 0.075, respectivaly

  12. Split thickness skin graft for cervicovaginal reconstruction in congenital atresia of cervix.

    Science.gov (United States)

    Zhang, Xuyin; Han, Tiantian; Ding, Jingxin; Hua, Keqin

    2015-10-01

    To introduce a new technique that combines laparoscopic and vaginal cervicovaginal reconstruction using split thickness skin graft in patients with congenital atresia of the cervix. Video article introducing a new surgical technique. University hospital. A 16-year-old patient with congenital cervical atresia, vaginal dysgenesis, and ovarian endometrial cyst. An original technique of combined laparoscopic and vaginal cervicovaginal reconstruction using split thickness skin graft for cervicovaginal reconstruction. A midline incision at the vaginal introitus was made, and a 9-cm canal was made between the bladder and the rectum using sharp and blunt dissection along the anatomic vaginal route, with the aid of laparoscopy to ensure correct orientation. A 14 × 12 cm split thickness skin graft was harvested from the right lateral thigh. By laparoscopy, the level of the lowest pole of the uterine cavity was exposed and the cervix was incised by shape dissection. The proximal segment of the harvested skin to the lower uterine segment was secured, and the distal segment was sutured with the upper margin of vulva vaginally. Surgical technique reports in anonymous patients are exempted from ethical approval by the Institutional Review Board. The patient gave consent to use the video in the article. The procedure was successfully completed. Since February 2013, our experiences of combined laparoscopic and vaginal cervicovaginal reconstruction using split thickness skin graft in 10 patients with congenital atresia of cervix were positive, with successful results and without complications or cervical, or vaginal stenosis. Our technique is feasible and safe for congenital atresia of cervix, with successful results and without complications or cervical or vaginal stenosis. Copyright © 2015 American Society for Reproductive Medicine. Published by Elsevier Inc. All rights reserved.

  13. Grafting of VO x/TiO2 catalyst on anodized aluminum plates for structured catalytic reactors

    International Nuclear Information System (INIS)

    Giornelli, Thierry; Loefberg, Axel; Bordes-Richard, Elisabeth

    2005-01-01

    Structured reactors are promising to carry out exothermic reactions because the heat transfer is better controlled than in usual packed-bed reactors. However the coating by oxide powders which must exhibit catalytic activity/selectivity while being mechanically stable is not so straightforward. We have studied the parameters to be controlled to coat aluminum walls by V 2 O 5 /TiO 2 catalysts which are used in the mild oxidation of hydrocarbons and NO x abatement. The dip-coating technique using metallic alcoholates has been chosen for the grafting of TiO 2 on Al 2 O 3 /Al, which is controlled by X-ray Photoelectron Spectroscopy (XPS). A monolayer of TiO 2 is first grafted, and then a porous film of TiO 2 -anatase is deposited by sol-gel. Finally, VO x species are grafted on titania and their loading again determined by XPS. Techniques such as Laser Raman Spectroscopy, Scanning Electron Microscopy are used to characterize the samples after each step, and the porous texture is determined. The layers are mechanically and thermally stable. The dispersion and nature of VO x species on TiO 2 /Al 2 O 3 /Al are similar to what is found in literature for TiO 2 powders, showing thereby that the shaping of anatase support on plates has not modified the chemical properties of VO x /TiO 2 -anatase system

  14. Ingenious route for ultraviolet-induced graft polymerization achieved on inorganic particle: Fabricating magnetic poly(acrylic acid) densely grafted nanocomposites for Cu{sup 2+} removal

    Energy Technology Data Exchange (ETDEWEB)

    Zhou, Qi, E-mail: roundzking@163.com [School of Environmental and Chemical Engineering, Shanghai University, 333 Nanchen Road, Shanghai, 200444 (China); Luo, Wenjun [Faculty of Material and Chemistry, China University of Geosciences, Wuhan, 430074 (China); Zhang, Xing [School of Environmental and Chemical Engineering, Shanghai University, 333 Nanchen Road, Shanghai, 200444 (China)

    2017-08-15

    Highlights: • A novel PAA brushes-decorated magnetic adsorbent was prepared successfully. • The preparation approach was simple, rapid, and efficient. • Densely polymer grafting can be achieved on inorganic substrate by the method. • The g-MNPs exhibits an outstanding adsorption performance for Cu{sup 2+}. • The Cu{sup 2+}-saturated adsorbent can be separated and regenerated easily. - Abstract: In this study, ultraviolet (UV)-induced graft technology is improved to be successfully applied on inorganic substrate for fabricating a novel poly(acrylic acid) (PAA) brushes-decorated magnetic nano-composite particles (g-MNPs) as a potential adsorbent toward Cu{sup 2+} ion. The most fascinating features of the resultant g-MNPs are the abundant and highly accessible carboxyl groups present in PAA brushes and the rapid separation from the medium by magnetic field after adsorption. Through the new and high-efficiency surface-initiated polymerization route, the densely PAA brushes was successfully immobilized on the MNPs surface with a high grafting yield of 88.3%. Excitingly, the g-MNPs exhibited an exceptional performance for Cu{sup 2+} adsorption, e.g., ultrahigh adsorption capacity (up to 152.1 mg g{sup −1}), rapid adsorption rate (within 30 min) and low residual concentration (below 1.3 ppm). Full kinetic and isotherm analysis as well as thermodynamic study were also undertaken, the results showed that Cu{sup 2+} adsorption followed Langmuir isotherm and the pseudo-second-order kinetic model, the adsorption rate was controlled by two sequential periods of external and intraparticle diffusion. According to the calculated value of thermodynamic parameters, the Cu{sup 2+} adsorption onto g-MNPs was a spontaneous endothermic process. Furthermore, the excellent reusability of the resultant adsorbent was also confirmed, which can keep above 95% adsorption capacity and desorption rate in 8 consecutive cycles.

  15. Polyethyleneglycol grafting of γ-alumina membranes for solvent resistant nanofiltration

    NARCIS (Netherlands)

    Tanardi, Cheryl; Catana, Romina; Barboiu, Mihai; Ayral, André; Vankelecom, Ivo F.J.; Nijmeijer, Arian; Winnubst, Aloysius J.A.

    2016-01-01

    A method is presented for grafting mesoporous g-alumina (pore size 5 nm), supported on an a-alumina ceramic membrane, with polyethylene glycols (PEG). The grafting performance of g-Al2O3 powders with various PEG grafting agents, having different molecular weights, alkoxy groups, and ureido

  16. The impact of slow graft function on graft outcome is comparable to delayed graft function in deceased donor kidney transplantation.

    Science.gov (United States)

    Shin, Jung-Ho; Koo, Eun Hee; Ha, Sung Hae; Park, Ji Hyeon; Jang, Hye Ryoun; Lee, Jung Eun; Park, Jae-Berm; Kim, Sung Joo; Jung, Sin-Ho; Kim, Yoon-Goo; Kim, Dae Joong; Oh, Ha Young; Huh, Wooseong

    2016-03-01

    Slow graft function (SGF) can influence overall prognosis in patients receiving deceased donor kidney transplantation (DKT). However, the impact of SGF on renal function remains uncertain. We investigated retrospectively renal function in cases with SGF compared with early graft function (EGF) and delayed graft function (DGF). Renal function after transplantation was analyzed in 199 patients who underwent DKT. Patients were classified into 130 (65.3 %) cases with EGF, 27 (13.6 %) cases with SGF, 6 (3.0 %) cases with DGF and one dialysis (DGF1), and 36 (18.1 %) cases with DGF and two or more dialyses (DGF2). The 1-year estimated glomerular filtration rate (eGFR) in the SGF group was lower than that in the EGF group (P = 0.027), but the rate of eGFR decline did not differ between the groups. The risk factors for renal function were evaluated using the area under the eGFR curve over 3 years (AUCeGFR). Donor age was negatively, and recipient age and the number of HLA matches were positively correlated with the AUCeGFR (all P DKT. Moreover, it was comparable to DGF. Efforts should be dedicated to minimizing the development of SGF and DGF.

  17. Clinical application of human adipose tissue-derived mesenchymal stem cells in progressive hemifacial atrophy (Parry-Romberg disease) with microfat grafting techniques using 3-dimensional computed tomography and 3-dimensional camera.

    Science.gov (United States)

    Koh, Kyung Suk; Oh, Tae Suk; Kim, Hoon; Chung, In Wook; Lee, Kang Woo; Lee, Hyo Bo; Park, Eun Jung; Jung, Jae Seob; Shin, Il Seob; Ra, Jeong Chan; Choi, Jong Woo

    2012-09-01

    Parry-Romberg disease is a rare condition that results in progressive hemifacial atrophy, involving the skin, dermis, subcutaneous fat, muscle, and, finally, cartilage and bone. Patients have been treated with dermofat or fat grafts or by microvascular free flap transfer. We hypothesized that adipose-derived stem cells (ASCs) may improve the results of microfat grafting through enhancing angiogenesis. We evaluated the utility of ASC in microfat grafting of patients with Parry-Romberg disease by measuring the change in the hemifacial volumes after injection of ASCs with microfat grafts or microfat grafts alone. In April 2008, this investigation was approved by the Korean Food and Drug Administration and the institutional review board of the Asan Medical Center (Seoul, Korea) that monitor investigator-initiated trials. Between May 2008 and January 2009, 10 volunteers with Parry-Romberg disease (5 men and 5 women; mean age, 28 y) were recruited; 5 received ASC and microfat grafts and 5 received microfat grafts only. The mean follow-up period was 15 months. Adipose-derived stem cells were obtained from abdominal fat by liposuction and were cultured for 2 weeks. On day 14, patients were injected with fat grafts alone or plus (in the test group) 1 × 10 ASCs. Patients were evaluated postoperatively using a 3-dimensional camera and 3-dimensional CT scans, and grafted fat volumes were objectively calculated. Successful outcomes were evident in all 5 patients receiving microfat grafts and ASCs, and the survival of grafted fat was better than in patients receiving microfat grafts alone. Before surgery, the mean difference between ipsilateral and contralateral hemiface volume in patients receiving microfat grafts and ASCs was 21.71 mL decreasing to 4.47 mL after surgery. Overall resorption in this ASC group was 20.59%. The mean preoperative difference in hemiface volume in those receiving microfat grafts alone was 8.32 mL decreasing to 3.89 mL after surgery. Overall

  18. Improvement of the polymer stability by radiation grafting

    International Nuclear Information System (INIS)

    Ranogajec, F.; Mlinac-Misak, M.

    2004-01-01

    Losses of the stabilizer due to extractability or volatility immediately affect the ultimate performance of polymer products. A new approach to increase the persistence of the stabilizer in the final product is to chemically bind it to the polymer backbone. Radiation grafting or crosslinking could be an efficient method for this, when the stabilizer is polymerizable. By a mutual gamma irradiation method photoprotector 2-hydroxy-4-(3-methacryloxy-2-hydroxy-propoxy) benzophenone has been readily grafted to low-density polyethylene in benzene, tetrahydrofuran and methanol solution, respectively. Surface grafting occurs in a methanol solution of stabilizer, while in benzene and tetrahydrofuran solutions of the stabilizer, grafting proceeds more or less in the inner parts of the polymeric film as well. UV stability tests and changes in the mechanical properties of artificially and naturally aged films indicate pronounced protective effect achieved by the grafted stabilizer. Surface grafting is an efficient photostabilization method since the grafted stabilizer is chemically bound to a polymeric surface and in this way the problem of evaporation of blended stabilizers during the prolonged use of polymeric materials is eliminated

  19. Radiation grafting of bis[2-(methacryloyloxy)ethyl]phosphate unto kenaf fiber for adsorption of rare earth elements

    International Nuclear Information System (INIS)

    Nor Azillah Fatimah Othman; Selambakkannu, S.; Norliza Ishak; Nor Azwin Shukri; Zulkafli Ghazali

    2016-01-01

    Full text: In this work kenaf bast fibers were used as trunk polymer for grafting with bis[2-(methacryloyloxy)ethyl]phosphate monomer through radiation induced grafting technique. Kenaf fibers were treated with different concentration of sodium chlorite (NaClO_2) solution at 70 degree Celsius for 6 hours. Kenaf fibers were irradiated with electron beam and reacted with bis[2-(methacryloyloxy)ethyl]phosphate/ water emulsion. Formation of grafting was observed from the increase in degree of grafting and confirmed by FTIR and SEM results. Effects of irradiation dose, reaction time, reaction temperature and monomer concentration on the degree of grafting were studied. Performance of the grafted kenaf fibers were then tested for adsorption of rare earth elements, namely Dysprosium, Neodymium and Holmium. (author)

  20. Mechanochemically conjugated PMHS/nano-SiO 2 hybrid and subsequent optimum grafting density study

    Science.gov (United States)

    Lin, Jinbin; Chen, Hongling; Yuan, Yongbing; Ji, Yan

    2011-08-01

    In this paper, we reported the preparation of poly(methylhydrosiloxane) (PMHS)/SiO 2 hybrid particles by mechanochemical method based on high energy ball milling (HEBM). The obtained hybrid particles were characterized by Fourier transform infrared (FT-IR) spectroscopy, 29Si CP (cross-polarization) MAS NMR, viscosity measurement, particle size distribution, thermal analysis (TGA, DSC and DTG), static contact angle (CA), field emission scanning electron microscopy (FE-SEM) and transmission electron microscopy (TEM). FT-IR and 29Si CP MAS NMR spectra indicate that PMHS is chemically anchored onto the surface of nano-SiO 2. Viscosity measurement, particle size distribution, FE-SEM and TEM demonstrate that an appropriate grafting density optimizes the dispersion of nanoparticles in poly(dimethylsiloxane) (PDMS) matrix, so lower viscosity can be achieved. Too high or too low grafting density may only achieve suboptimal and poor dispersions. The optimum grafting density of PMHS on nano-SiO 2 was determined by thermal analysis, with approximately 0.0531 PMHS/nm 2. Static contact angle measurement indicates that the water contact angle of hybrid particles is modulated by changing the grafting density of PMHS on nano-SiO 2. The CA value of PMHS/SiO 2 hybrid with optimum grafting density is 139.4°, and the highest CA value of PMHS/SiO 2 hybrid is approximately 158.2°.

  1. Another Method of Building 2D Entropy to Realize Automatic Segmentation

    International Nuclear Information System (INIS)

    Zhang, Y F; Zhang, Y

    2006-01-01

    2D entropy formed during the process of building 2D histogram can realize automatic segmentation. Traditional method utilizes central pixel grey value and the others or all of pixels grey mean value in 4-neighbor to build 2D histogram. In fact, the change of the greyscale value between two ''invariable position vectors'' cannot represent the total characteristics among neighbour pixels very well. A new method is proposed which makes use of minimum grey value in the 4-neighbor and of maximum grey value in the 3x3 neighbour except pixels of the 4-neighbor. New method and traditional one are used in contrast to realize image automatic segmentation. The experimental results of the classical image prove the new method is effective

  2. Segmentation of the lumen and media-adventitia boundaries of the common carotid artery from 3D ultrasound images

    Science.gov (United States)

    Ukwatta, E.; Awad, J.; Ward, A. D.; Samarabandu, J.; Krasinski, A.; Parraga, G.; Fenster, A.

    2011-03-01

    Three-dimensional ultrasound (3D US) vessel wall volume (VWV) measurements provide high measurement sensitivity and reproducibility for the monitoring and assessment of carotid atherosclerosis. In this paper, we describe a semiautomated approach based on the level set method to delineate the media-adventitia and lumen boundaries of the common carotid artery from 3D US images to support the computation of VWV. Due to the presence of plaque and US image artifacts, the carotid arteries are challenging to segment using image information alone. Our segmentation framework combines several image cues with domain knowledge and limited user interaction. Our method was evaluated with respect to manually outlined boundaries on 430 2D US images extracted from 3D US images of 30 patients who have carotid stenosis of 60% or more. The VWV given by our method differed from that given by manual segmentation by 6.7% +/- 5.0%. For the media-adventitia and lumen segmentations, respectively, our method yielded Dice coefficients of 95.2% +/- 1.6%, 94.3% +/- 2.6%, mean absolute distances of 0.3 +/- 0.1 mm, 0.2 +/- 0.1 mm, maximum absolute distances of 0.8 +/- 0.4 mm, 0.6 +/- 0.3 mm, and volume differences of 4.2% +/- 3.1%, 3.4% +/- 2.6%. The realization of a semi-automated segmentation method will accelerate the translation of 3D carotid US to clinical care for the rapid, non-invasive, and economical monitoring of atherosclerotic disease progression and regression during therapy.

  3. Proton conducting graft copolymers with tunable length and density of phosphonated side chains for fuel cell membranes

    DEFF Research Database (Denmark)

    Dimitrov, Ivaylo; Takamuku, Shogo; Jankova Atanasova, Katja

    2014-01-01

    Polysulfones functionalized with highly phosphonated poly(pentafluorostyrene) side chains of different lengths were synthesized applying controlled polymerization and modification methods. The graft copolymers' thermal properties were evaluated by differential scanning calorimetry and thermal...... gravimetrical analyses. The proton conductivity of membrane prepared from the graft copolymer with the shortest phosphonated side chains was 134 mS cm(-1) at 100 degrees C under fully immersed conditions. The graft copolymer TEM image shows a nanophase separation of ion-rich segments within the polysulfone...

  4. Improvement of polymer stability by radiation grafting

    International Nuclear Information System (INIS)

    Ranogajec, F.; Mlinac-Misak, M.

    1999-01-01

    Losses of the stabilizer due to extractability or volatility immediately affect ultimate performance of polymer product. A new approach to increase the persistence of the stabilizer in the final product is to chemically bind it to the polymer backbone. Radiation grafting or crosslinking could be an efficient method for this, when the stabilizer is polymerizable. By a mutual gamma irradiation method, photoprotector 2-hydroxy-4-(3-methacryloxy-2- hydroxy-propoxy) benzophenone (HMB) has been readily grafted to low density polyethylene (LDPE) in benzene, tetrahydrofuran and methanol solution, respectively. Surface grafting occurs in a methanol solution of stabilizer, while in benzene and tetrahydrofuran solutions of stabilizer, grafting proceeds more or less in the inner parts of the polymeric film as well. The grafted LDPE film in methanol and tetrahydrofuran (containing 1 w/w % of grafted HMB), 1 w/w % blended HMB with LDPE and nongrafted LDPE film, were all exposed to accelerated aging and natural weathering and their spectral changes, expressed by the carbonyl index, were then compared. The change of elongation at break and tensile strength were measured in the course of aging. UV stability tests on aged films and change in mechanical properties indicate a pronounced protective effect achieved by grafted stabilizer. Grafting in methanol solution appears to be an efficient photostabilization treatment and the most economical with respect to the consumption of monomer, the grafting yield being less than 0.5%. Surface grafting is an efficient photostabilization method since grafted stabilizer is chemically bound to a polymeric surface and in this way the problem of evaporation of blended stabilizers during the prolonged use of polymeric materials is eliminated. (author)

  5. Unprotected autogenous bone block grafts in anterior maxilla: Resorption rates and clinical outcomes

    Directory of Open Access Journals (Sweden)

    Kosanić Ivan

    2017-01-01

    Full Text Available Background/Aim. The use of autogenous bone grafts for augmentation of the resorbed alveolar ridge is still considered the gold standard in implant dentistry. The aim of this study was to analyze the resorption rate of autogenous bone block grafts from the retromolar region placed in the frontal segment of the upper jaw unprotected by barrier membranes, to assess the stability of implants placed into the grafted bone, as well as to monitor its changes during the healing period. Methods. The study included 18 patients with a total of 20 grafted sites. The residual alveolar ridge was measured before and after the augmentation and prior to implant placement. All implants were restored with provisional crowns within 48 hours after the placement. Implant stability was assessed using resonance frequency analysis. Results. The average period from ridge augmentation to reentry was 5.4 months (range 4–6 months. At reentry the healed alveolar ridge had a mean width of 6.1 ± 1.27 mm. The mean calculated width gain was 3.04 ± 1.22 mm. The overall surface resorption of block grafts was 0.68 ± 0.69 mm (18.85%. At the time of implant placement the mean value of implant stability quotient (ISQ was 71.25 ± 5.77. The lowest ISQ values were noted after three weeks of healing, followed by a gradual increase until week 12. After 12 weeks implants showed significantly higher ISQ values compared to primary stability (p < 0.05 Wilcoxon signed ranks test. During the 3-years followup period no cases of implant loss were recorded. Conclusion. Despite a significant resorption of bone grafts, it was possible to place implants in all the cases and to use the immediate loading protocol without affecting implant survival rate. [Project of the Serbian Ministry of Education, Science and Technological Development, Grant no.175021

  6. Novel anterior cruciate ligament graft fixation device reduces slippage

    Directory of Open Access Journals (Sweden)

    Lopez MJ

    2013-05-01

    Full Text Available Mandi J Lopez,1 Allen Borne,2 W Todd Monroe,3 Prakash Bommala,1 Laura Kelly,1 Nan Zhang11Laboratory for Equine and Comparative Orthopedic Research, Department of Veterinary Clinical Sciences, School of Veterinary Medicine, Louisiana State University, Baton Rouge, 2Louisiana State University, New Orleans Health Sciences Center, School of Medicine, New Orleans, 3Department of Biological and Agricultural Engineering, Agricultural Center, Louisiana State University, Baton Rouge, LA, USAAbstract: Clinically significant laxity occurs in 10%–30% of knees after anterior cruciate ligament reconstruction. Graft slippage and tension loss at the hamstring graft tibial fixation site during and after reconstruction surgery contribute to postoperative joint laxity and are detrimental to long-term knee stability and graft properties. Limiting graft slippage will reduce associated complications. We sought to compare the in vitro mechanical properties and in vivo joint stabilization, postoperative limb use, and graft incorporation of the novel GraftGrab™ (GG device designed to reduce hamstring graft tibial fixation slippage with the commercially available bioabsorbable Bio-Post™ and spiked washer (BP. Mechanical testing was performed on canine tibia-hamstring graft constructs to quantify initial fixation properties. In vivo joint stabilization, postoperative limb use and graft incorporation of hamstring graft reconstructions were determined in a canine model. Outcomes included tibial translation and ground reaction forces preoperatively and 4 and 8 weeks postoperatively, three-dimensional graft and bone tunnel dimensions at the latter two time points, and graft-bone microstructure, as well as mechanical properties 8 weeks after implantation. Immediately after fixation, all grafts slipped from the BP constructs versus about 30% of GG constructs. In vivo limb use remained low, and tibial translation increased with time in the BP cohort. These results together

  7. Development and Assessment of a 3D-Printed Scaffold with rhBMP-2 for an Implant Surgical Guide Stent and Bone Graft Material: A Pilot Animal Study

    OpenAIRE

    Bae, Ji Cheol; Lee, Jin-Ju; Shim, Jin-Hyung; Park, Keun-Ho; Lee, Jeong-Seok; Bae, Eun-Bin; Choi, Jae-Won; Huh, Jung-Bo

    2017-01-01

    In this study, a new concept of a 3D-printed scaffold was introduced for the accurate placement of an implant and the application of a recombinant human bone morphogenetic protein-2 (rhBMP-2)-loaded bone graft. This preliminary study was conducted using two adult beagles to evaluate the 3D-printed polycaprolactone (PCL)/β-tricalcium phosphate (β-TCP)/bone decellularized extracellular matrix (bdECM) scaffold conjugated with rhBMP-2 for the simultaneous use as an implant surgical guide stent an...

  8. Study on superhydrophobic surfaces of octanol grafted electrospun silica nanofibers

    International Nuclear Information System (INIS)

    Meng, Long-Yue; Han, Shunyu; Jiang, Nanzhe; Meng, Wan

    2014-01-01

    In this work, superhydrophobic surfaces were successfully prepared by grafting of octanol on the surface of electrospun silica nanofibers (SNFs). The chemical compositions and microstructures of the prepared SNFs surfaces were investigated by using N 2 full isotherms, Fourier transform infrared spectroscopy (FT-IR), thermogravimetric analysis (TGA), scanning electron microscopy (SEM), transmission electron microscopy (TEM), and contact angle measurements. The results indicate that the surface of SNFs changed from being superhydrophilic to superhydrophobic by octanol surface grafting. The contact angle of the octanol-grafted SNFs was close to 150.2° because their surface was modified by –(CH 2 ) 6 –CH 3 groups. The 3D network of SNFs networks and the low surface energy of the alkyl side chains played important roles in creating the superhydrophobic surface of the SNFs. - Highlights: • Superhydrophobic surface was prepared from electrospinning SNFs and by grafting octanol on their surface. • The surface of SNFs changed from superhydrophilic to superhydrophobic. • The CA of MSNFs became 150.2° because of interactions between grafted octyl groups

  9. Study on superhydrophobic surfaces of octanol grafted electrospun silica nanofibers

    Energy Technology Data Exchange (ETDEWEB)

    Meng, Long-Yue [Key Laboratory of Natural Resources of Changbai Mountain and Functional Molecules, Yanbian University, Yanji 133002 (China); Department of Chemical Engineering, College of Engineering, Yanbian University, 977 Gongyuan Road, Yanji 133002 (China); Han, Shunyu; Jiang, Nanzhe [Department of Chemical Engineering, College of Engineering, Yanbian University, 977 Gongyuan Road, Yanji 133002 (China); Meng, Wan, E-mail: mengw@ybu.edu.cn [Department of Chemical Engineering, College of Engineering, Yanbian University, 977 Gongyuan Road, Yanji 133002 (China)

    2014-12-15

    In this work, superhydrophobic surfaces were successfully prepared by grafting of octanol on the surface of electrospun silica nanofibers (SNFs). The chemical compositions and microstructures of the prepared SNFs surfaces were investigated by using N{sub 2} full isotherms, Fourier transform infrared spectroscopy (FT-IR), thermogravimetric analysis (TGA), scanning electron microscopy (SEM), transmission electron microscopy (TEM), and contact angle measurements. The results indicate that the surface of SNFs changed from being superhydrophilic to superhydrophobic by octanol surface grafting. The contact angle of the octanol-grafted SNFs was close to 150.2° because their surface was modified by –(CH{sub 2}){sub 6}–CH{sub 3} groups. The 3D network of SNFs networks and the low surface energy of the alkyl side chains played important roles in creating the superhydrophobic surface of the SNFs. - Highlights: • Superhydrophobic surface was prepared from electrospinning SNFs and by grafting octanol on their surface. • The surface of SNFs changed from superhydrophilic to superhydrophobic. • The CA of MSNFs became 150.2° because of interactions between grafted octyl groups.

  10. Angiographic Evaluation of Carotid Artery Grafting with Prefabricated Small-Diameter, Small-Intestinal Submucosa Grafts in Sheep

    International Nuclear Information System (INIS)

    Pavcnik, Dusan; Obermiller, Josef; Uchida, Barry T.; Van Alstine, William; Edwards, James M.; Landry, Gregory J.; Kaufman, John A.; Keller, Frederick S.; Roesch, Josef

    2009-01-01

    The purpose of this study was to report the longitudinal angiographic evaluation of prefabricated lyophilized small-intestinal submucosa (SIS) grafts placed in ovine carotid arteries and to demonstrate a variety of complications that developed. A total of 24 grafts, 10 cm long and 6 mm in diameter, were placed surgically as interposition grafts. Graft patency at 1 week was evaluated by Doppler ultrasound, and angiography was used for follow-up at 1 month and at 3 to 4 months. A 90% patency rate was found at 1 week, 65% at 1 month, and 30% at 3 to 4 months. On the patent grafts, angiography demonstrated a variety of changes, such as anastomotic stenoses, graft diffuse dilations and dissections, and aneurysm formation. These findings have not been previously demonstrated angiographically by other investigators reporting results with small-diameter vessel grafts made from fresh small-intestinal submucosa (SIS). The complications found were partially related to the graft construction from four SIS layers. Detailed longitudinal angiographic study should become an essential part of any future evaluation of small-vessel SIS grafting.

  11. Air Pump-Assisted Graft Centration, Graft Edge Unfolding, and Graft Uncreasing in Young Donor Graft Pre-Descemet Endothelial Keratoplasty.

    Science.gov (United States)

    Jacob, Soosan; Narasimhan, Smita; Agarwal, Amar; Agarwal, Athiya; A I, Saijimol

    2017-08-01

    To assess an air pump-assisted technique for graft centration, graft edge unfolding, and graft uncreasing while performing pre-Descemet endothelial keratoplasty (PDEK) using young donor grafts. Continuous pressurized air infusion was used for graft centration, graft edge unfolding, and graft unwrinkling. Ten eyes of 10 patients underwent PDEK with donors aged below 40 years. In all eyes, the donor scrolled into tight scrolls. In all cases, the air pump-assisted technique was effective in positioning and centering the graft accurately and in straightening infolded graft edges and smoothing out graft creases and wrinkles. Endothelial cell loss was 38.6%. Postoperative best-corrected visual acuity at 6 months was 0.66 ± 0.25 in decimal equivalent. Continuous pressurized air infusion acted as a third hand providing a continuous pressure head that supported the graft and prevented graft dislocation as well as anterior chamber collapse during intraocular maneuvering. Adequate maneuvering space was available in all cases, and bleeding, if any, was tamponaded successfully in all cases. Although very young donor grafts may be used for PDEK, they are difficult to center and unroll completely before floating against host stroma. An air pump-assisted technique using continuous pressurized air infusion allows successful final graft positioning even with very young donor corneas. It thus makes surgery easier as several key steps are made easier to handle. It additionally helps in tamponading hemorrhage during peripheral iridectomy, increasing surgical space, preventing fluctuations in the anterior chamber depth, and promoting graft adherence.

  12. Prosthetic vascular graft infection through a median sternotomy: a multicentre review †.

    Science.gov (United States)

    Oda, Tatsuya; Minatoya, Kenji; Kobayashi, Junjiro; Okita, Yutaka; Akashi, Hidetoshi; Tanaka, Hiroyuki; Kawaharada, Nobuyoshi; Saiki, Yoshikatsu; Kuniyoshi, Yukio; Nishimura, Kunihiro

    2015-06-01

    The aim of this study is to analyse the treatment outcomes of thoracic prosthetic graft infection. A retrospective chart review was conducted at six hospitals and included the records of 68 patients treated for postoperative prosthetic vascular graft infection (mean age: 62.3 ± 15.1, male 51) from January 2000 to December 2013. The number of patients and the locations of the treated infections were as follows: 13 for aortic root, 16 for ascending aorta, 35 for aortic arch and 4 for aortic root to arch. In-hospital infection occurred in 43 patients and after discharge in 25. The mean follow-up time was 2.0 ± 2.3 years. The follow-up rate was 94.1%. The most commonly isolated micro-organism was Staphylococcus aureus (72.1%). Rereplacement of infectious graft was performed in 18 patients (Dacron graft in 12, homograft in 4 and rifampicin-bonded Dacron graft in 2). The overall hospital mortality rate was 35.3% (24/68). The mortality rate among the patients with graft rereplacement was 33.3% (6/18), with pedicled muscle flaps or pedicled omental flaps to cover the graft 25.9% (7/27), with irrigation 55.0% (11/20) and on antibiotic therapy only 0% (0/3). Our multivariate analysis demonstrated that the risk factors of hospital death increased in the absence of pedicled flaps (muscle or omentum) to cover the graft (P = 0.001), age over 55 (P = 0.003), time from onset of initial operation prosthetic vascular graft infection have not been satisfactory. However, the use of pedicled muscle or omental flaps to cover the graft could improve the outcomes. © The Author 2015. Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery. All rights reserved.

  13. Global left ventricular function in cardiac CT. Evaluation of an automated 3D region-growing segmentation algorithm

    International Nuclear Information System (INIS)

    Muehlenbruch, Georg; Das, Marco; Hohl, Christian; Wildberger, Joachim E.; Guenther, Rolf W.; Mahnken, Andreas H.; Rinck, Daniel; Flohr, Thomas G.; Koos, Ralf; Knackstedt, Christian

    2006-01-01

    The purpose was to evaluate a new semi-automated 3D region-growing segmentation algorithm for functional analysis of the left ventricle in multislice CT (MSCT) of the heart. Twenty patients underwent contrast-enhanced MSCT of the heart (collimation 16 x 0.75 mm; 120 kV; 550 mAseff). Multiphase image reconstructions with 1-mm axial slices and 8-mm short-axis slices were performed. Left ventricular volume measurements (end-diastolic volume, end-systolic volume, ejection fraction and stroke volume) from manually drawn endocardial contours in the short axis slices were compared to semi-automated region-growing segmentation of the left ventricle from the 1-mm axial slices. The post-processing-time for both methods was recorded. Applying the new region-growing algorithm in 13/20 patients (65%), proper segmentation of the left ventricle was feasible. In these patients, the signal-to-noise ratio was higher than in the remaining patients (3.2±1.0 vs. 2.6±0.6). Volume measurements of both segmentation algorithms showed an excellent correlation (all P≤0.0001); the limits of agreement for the ejection fraction were 2.3±8.3 ml. In the patients with proper segmentation the mean post-processing time using the region-growing algorithm was diminished by 44.2%. On the basis of a good contrast-enhanced data set, a left ventricular volume analysis using the new semi-automated region-growing segmentation algorithm is technically feasible, accurate and more time-effective. (orig.)

  14. Modeling polymer-induced interactions between two grafted surfaces: comparison between interfacial statistical associating fluid theory and self-consistent field theory.

    Science.gov (United States)

    Jain, Shekhar; Ginzburg, Valeriy V; Jog, Prasanna; Weinhold, Jeffrey; Srivastava, Rakesh; Chapman, Walter G

    2009-07-28

    The interaction between two polymer grafted surfaces is important in many applications, such as nanocomposites, colloid stabilization, and polymer alloys. In our previous work [Jain et al., J. Chem. Phys. 128, 154910 (2008)], we showed that interfacial statistical associating fluid density theory (iSAFT) successfully calculates the structure of grafted polymer chains in the absence/presence of a free polymer. In the current work, we have applied this density functional theory to calculate the force of interaction between two such grafted monolayers in implicit good solvent conditions. In particular, we have considered the case where the segment sizes of the free (sigma(f)) and grafted (sigma(g)) polymers are different. The interactions between the two monolayers in the absence of the free polymer are always repulsive. However, in the presence of the free polymer, the force either can be purely repulsive or can have an attractive minimum depending upon the relative chain lengths of the free (N(f)) and grafted polymers (N(g)). The attractive minimum is observed only when the ratio alpha = N(f)/N(g) is greater than a critical value. We find that these critical values of alpha satisfy the following scaling relation: rho(g) square root(N(g)) beta(3) proportional to alpha(-lambda), where beta = sigma(f)/sigma(g) and lambda is the scaling exponent. For beta = 1 or the same segment sizes of the free and grafted polymers, this scaling relation is in agreement with those from previous theoretical studies using self-consistent field theory (SCFT). Detailed comparisons between iSAFT and SCFT are made for the structures of the monolayers and their forces of interaction. These comparisons lead to interesting implications for the modeling of nanocomposite thermodynamics.

  15. Kidney transplant graft outcomes in 379 257 recipients on 3 continents.

    Science.gov (United States)

    Merion, Robert M; Goodrich, Nathan P; Johnson, Rachel J; McDonald, Stephen P; Russ, Graeme R; Gillespie, Brenda W; Collett, David

    2018-03-24

    Kidney transplant outcomes that vary by program or geopolitical unit may result from variability in practice patterns or health care delivery systems. In this collaborative study, we compared kidney graft outcomes among 4 countries (United States, United Kingdom, Australia, and New Zealand) on 3 continents. We analyzed transplant and follow-up registry data from 1988-2014 for 379 257 recipients of first kidney-only transplants using Cox regression. Compared to the United States, 1-year adjusted graft failure risk was significantly higher in the United Kingdom (hazard ratio [HR] 1.22, 95% confidence interval [CI] 1.18-1.26, P < .001) and New Zealand (hazard ratio [HR] 1.29, 95% confidence interval [CI] 1.14-1.46, P < .001), but lower in Australia (HR 0.90, 95% CI 0.84-0.96, P = .001). In contrast, long-term adjusted graft failure risk (conditional on 1-year function) was significantly higher in the United States compared to Australia, New Zealand, and the United Kingdom (HR 0.74, 0.75, and 0.74, respectively; each P < .001). Thus long-term kidney graft outcomes are approximately 25% worse in the United States than in 3 other countries with well-developed kidney transplant systems. Case mix differences and residual confounding from unmeasured factors were found to be unlikely explanations. These findings suggest that identification of potentially modifiable country-specific differences in care delivery and/or practice patterns should be sought. © 2018 The American Society of Transplantation and the American Society of Transplant Surgeons.

  16. State-of-the-art flux pinning in YBa2Cu3O7-δ by the creation of highly linear, segmented nanorods of Ba2(Y /Gd)(Nb/Ta)O6 together with nanoparticles of (Y /Gd)2O3 and (Y /Gd)Ba2Cu4O8

    International Nuclear Information System (INIS)

    Ercolano, G; Bianchetti, M; Wimbush, S C; Harrington, S A; MacManus-Driscoll, J L; Wang, H; Lee, J H

    2011-01-01

    Self-assembled, segmented nanorods of c-axis-aligned Ba 2 (Y /Gd)(Nb/Ta)O 6 as well as randomly distributed nanoparticles of (Y /Gd) 2 O 3 and (Y /Gd)Ba 2 Cu 4 O 8 were grown into YBa 2 Cu 3 O 7-δ (YBCO) thin films by pulsed-laser deposition. The complex pinning landscape proves to be extremely effective, particularly at higher fields where the segmented vortices yield a plateau in critical current density (J c ) with field angle around 60 0 . In 0.3 μm thick films, the J c values are higher than 1 MA cm -2 at 2.5 T (H||c axis). Owing to the combined interactions of the vortices with the different pinning centres, interesting new features are observed at high fields in the angular dependence of J c .

  17. Bone grafting: An overview

    Directory of Open Access Journals (Sweden)

    D. O. Joshi

    2010-08-01

    the surgeon. A search for ideal bone graft is on and may continue till time to time. [Vet World 2010; 3(4.000: 198-200

  18. Automated segmentation of blood-flow regions in large thoracic arteries using 3D-cine PC-MRI measurements.

    Science.gov (United States)

    van Pelt, Roy; Nguyen, Huy; ter Haar Romeny, Bart; Vilanova, Anna

    2012-03-01

    Quantitative analysis of vascular blood flow, acquired by phase-contrast MRI, requires accurate segmentation of the vessel lumen. In clinical practice, 2D-cine velocity-encoded slices are inspected, and the lumen is segmented manually. However, segmentation of time-resolved volumetric blood-flow measurements is a tedious and time-consuming task requiring automation. Automated segmentation of large thoracic arteries, based solely on the 3D-cine phase-contrast MRI (PC-MRI) blood-flow data, was done. An active surface model, which is fast and topologically stable, was used. The active surface model requires an initial surface, approximating the desired segmentation. A method to generate this surface was developed based on a voxel-wise temporal maximum of blood-flow velocities. The active surface model balances forces, based on the surface structure and image features derived from the blood-flow data. The segmentation results were validated using volunteer studies, including time-resolved 3D and 2D blood-flow data. The segmented surface was intersected with a velocity-encoded PC-MRI slice, resulting in a cross-sectional contour of the lumen. These cross-sections were compared to reference contours that were manually delineated on high-resolution 2D-cine slices. The automated approach closely approximates the manual blood-flow segmentations, with error distances on the order of the voxel size. The initial surface provides a close approximation of the desired luminal geometry. This improves the convergence time of the active surface and facilitates parametrization. An active surface approach for vessel lumen segmentation was developed, suitable for quantitative analysis of 3D-cine PC-MRI blood-flow data. As opposed to prior thresholding and level-set approaches, the active surface model is topologically stable. A method to generate an initial approximate surface was developed, and various features that influence the segmentation model were evaluated. The active surface

  19. In Situ Synthesis of Poly(methyl methacrylate/SiO2 Hybrid Nanocomposites via “Grafting Onto” Strategy Based on UV Irradiation in the Presence of Iron Aqueous Solution

    Directory of Open Access Journals (Sweden)

    Hong Zhang

    2012-01-01

    Full Text Available Poly(methyl methacrylate/SiO2 (PMMA/SiO2 hybrid composites were prepared via “grafting onto” strategy based on UV irradiation in the presence of iron aqueous solution. Two steps were used to graft polymethyl methacrylate (PMMA onto the surface of nanosilica, anchoring 3-(methacryloxy propyl trimethoxysilane (MPTS onto the surface of nanosilica to modify it with double bonds, and then grafting PMMA onto the surface of nanosilica with FeCl3 as photoinitiator. The products were characterized by FT-IR, TGA, TEM, DLS, and XPS. The results showed that it is easy to graft PMMA onto the surface of nanosilica under UV irradiation, and the hybrid particles are monodisperse and have core-shell structure with nanosilica as the core and PMMA layers as the shell. Furthermore, the products initiated by FeCl3 have higher monomer conversion, percent grafting, and better monodispersion compared with the products initiated by traditional photoinitiator such as 2-hydroxy-4-(2-hydroxyethoxy-2-methyl-propiophenone (Irgacure 2959.

  20. In situ polymerization and characterization of grafted poly (3,4-ethylenedioxythiophene)/multiwalled carbon nanotubes composite with high electrochemical performances

    International Nuclear Information System (INIS)

    Bai, Xiaoxia; Hu, Xiujie; Zhou, Shuyun; Yan, Jun; Sun, Chenghua; Chen, Ping; Li, Laifeng

    2013-01-01

    Graphical abstract: The homogeneously grafted PEDOT/MWCNTs containing numerous whorl fingerprint-like open ends endows with excellent electrochemical performances. Highlights: ► A ternary phase system with the surfactant AOT is utilized to efficiently solve the problem of the aggregation of MWCNTs. ► The homogenously grafted PEDOT/MWCNTs composite is synthesized by in situ chemical polymerization in the ternary phase system. ► The core–shell nanotubes contain many whorl fingerprint-like open ends that are greatly favorable for the transportation of the electrons and ions. ► The energy density of grafted PEDOT/MWCNTs has been enhanced by a factor of four comparing to that of native MWCNTs. ► The grafted PEDOT/MWCNTs composite manifests better cycle durability than both the constituents. - Abstract: The homogenously grafted composite of poly (3,4-ethylenedioxythiophene)/multiwalled carbon nanotubes (PEDOT/MWCNTs) is synthesized by in situ chemical polymerization in a ternary phase system. When carbon nanotubes are dispersed in this system containing sodium bis(2-ethylhexyl) sulfosuccinate (AOT), the surfactant AOT can efficiently hinter the aggregation of MWCNTs by absorbing and arranging regularly on the MWCNT surface. It is greatly advantageous to the stabilization of MWCNTs, which leads to the equally grafted composite. Its morphology was observed by scanning and transmission electron microscopes. Especially, the core–shell nanotubes contain many whorl fingerprint-like open ends that are efficiently favorable for the transportation of the electrons and ions. Such grafted PEDOT/MWCNTs composite nanotubes manifest enhanced electrochemical performances. We investigate the application of PEDOT/MWCNTs as a high-property supercapacitor and test its capacitive performance by cyclic voltammetry, galvanostatic charge/discharge and electrochemical impedance spectroscopy. The energy density of grafted composite, 11.3 Wh kg −1 , has been enhanced by a factor

  1. Salt-Induced Control of the Grafting Density in Poly(ethylene glycol) Brush Layers by a Grafting-to Approach

    DEFF Research Database (Denmark)

    Ortiz, Roberto; Olsen, Stefan; Thormann, Esben

    2018-01-01

    In this work, a method to obtain control of the grafting density during the formation of polymer brush layers by the grafting-to method of thiolated poly(ethylene glycol) onto gold is presented. The grafting density of the polymer chains was adjusted by adding Na2SO4 in concentrations between 0.......2 and 0.9 M to the aqueous polymer solution during the grafting process. The obtained grafting densities ranged from 0.26 to 1.60 chains nm-2, as determined by surface plasmon resonance. The kinetics of the grafting process were studied in situ by a quartz crystal microbalance with dissipation......, and a mushroom to brush conformational transition was observed when the polymer was grafted in the presence of Na2SO4. The transition from mushroom to brush was only observed for long periods of grafting, highlighting the importance of time to obtain high grafting densities. Finally, the prepared brush layer...

  2. Radiation-grafting of 2-hydroxyethylmethacrylate and oligo (ethylene glycol) methyl ether methacrylate onto polypropylene films by one step method

    Energy Technology Data Exchange (ETDEWEB)

    Ramirez-Jimenez, Alejandro [Departamento de Quimica de Radiaciones y Radioquimica, Instituto de Ciencias Nucleares, Universidad Nacional Autonoma de Mexico, Circuito Exterior, Ciudad Universitaria, Mexico DF 04510 (Mexico); Alvarez-Lorenzo, Carmen; Concheiro, Angel [Departamento de Farmacia y Tecnologia Farmaceutica, Universidad de Santiago de Compostela, 15782-Santiago de Compostela (Spain); Bucio, Emilio, E-mail: ebucio@nucleares.unam.mx [Departamento de Quimica de Radiaciones y Radioquimica, Instituto de Ciencias Nucleares, Universidad Nacional Autonoma de Mexico, Circuito Exterior, Ciudad Universitaria, Mexico DF 04510 (Mexico)

    2012-01-15

    Polypropylene films were modified with 2-hydroxyethylmethacrylate (HEMA) and oligo (ethylene glycol) methyl ether methacrylate (OEGMA) using the pre-irradiation method with gamma-rays (one step method). The effect of absorbed dose from 10 to 100 kGy, temperature (50, 60, and 70 {sup o}C), monomer concentration between 12.5% and 62.5%, monomers ratio from 10% to 90% and reaction time from 5 to 50 h; on the degree of grafting was determined. The grafted samples were analyzed by FTIR-ATR, TGA, DSC, swelling, and contact angle. Grafts onto polymeric films between 3% and 109% were obtained at doses from 10 to 100 kGy and a dose rate around 7.4 kGy/h. The graft percent increased with the content in HEMA in the HEMA:OEGMA feed mixture, which indicates a lower reactivity of OEGMA compared to HEMA. The hydrogel layer grafted on the polypropylene substrate increases the hydrophilicity of the surface and also provides certain temperature-responsiveness, which may be of interest for biomedical applications. - Highlights: > PP was grafted with a hydrogel layer applying the {gamma}-ray pre-irradiation method. > Effects of radiation dose, time, temperature and monomers concentration were evaluated. > Grafted layer increases the hydrophilicity of PP films. > HEMA and OEGMA grafted onto PP may be of interest for biomedical applications.

  3. Patch Grafting Using an Ologen Collagen Matrix to Manage Tubal Exposure in Glaucoma Tube Shunt Surgery

    Directory of Open Access Journals (Sweden)

    Masaki Tanito

    2018-01-01

    Full Text Available Purpose: To report the results using an ologen Collagen Matrix as a patch graft in eyes with tubal exposure after tube shunt surgery. Case Reports: Case 1 was an 82-year-old man with tubal exposure in his right eye 26 months after receiving a Baerveldt glaucoma implant. The tube was covered by surrounding conjunctival tissue combined with subconjunctival placement of an ologen Collagen Matrix as a patch graft. Two years after implantation, the tube was not exposed. Anterior-segment optical coherence tomography (AS-OCT showed dense conjunctival tissue over the tube. Case 2 was an 82-year-old man with peripheral keratitis, anterior scleritis, and secondary glaucoma in the right eye who underwent tube shunt surgery using an Ahmed glaucoma valve and cataract surgery. Intraoperatively, scleritis-related scleral thinning prevented the tube from being covered fully by an autologous scleral flap. An ologen Collagen Matrix was placed over the scleral flap as a patch graft. Seventeen months after implantation, the tube was not exposed. Case 3 was a 52-year-old man with diabetic maculopathy and steroid-induced glaucoma in the right eye who underwent tube shunt surgery using an Ahmed glaucoma valve. Intraoperatively, a flap defect prevented the tube from being covered fully by an autologous scleral flap. An ologen Collagen Matrix was placed over the scleral flap as a patch graft. Three weeks postoperatively, AS-OCT showed thick subconjunctival tissue over the tube. Three months after implantation, the tube was not exposed. Conclusions: The ologen Collagen Matrix can be used successfully as a patch graft to prevent and treat tubal exposure after tube shunt surgery.

  4. 3-D segmentation of retinal blood vessels in spectral-domain OCT volumes of the optic nerve head

    Science.gov (United States)

    Lee, Kyungmoo; Abràmoff, Michael D.; Niemeijer, Meindert; Garvin, Mona K.; Sonka, Milan

    2010-03-01

    Segmentation of retinal blood vessels can provide important information for detecting and tracking retinal vascular diseases including diabetic retinopathy, arterial hypertension, arteriosclerosis and retinopathy of prematurity (ROP). Many studies on 2-D segmentation of retinal blood vessels from a variety of medical images have been performed. However, 3-D segmentation of retinal blood vessels from spectral-domain optical coherence tomography (OCT) volumes, which is capable of providing geometrically accurate vessel models, to the best of our knowledge, has not been previously studied. The purpose of this study is to develop and evaluate a method that can automatically detect 3-D retinal blood vessels from spectral-domain OCT scans centered on the optic nerve head (ONH). The proposed method utilized a fast multiscale 3-D graph search to segment retinal surfaces as well as a triangular mesh-based 3-D graph search to detect retinal blood vessels. An experiment on 30 ONH-centered OCT scans (15 right eye scans and 15 left eye scans) from 15 subjects was performed, and the mean unsigned error in 3-D of the computer segmentations compared with the independent standard obtained from a retinal specialist was 3.4 +/- 2.5 voxels (0.10 +/- 0.07 mm).

  5. Automatic gallbladder segmentation using combined 2D and 3D shape features to perform volumetric analysis in native and secretin-enhanced MRCP sequences.

    Science.gov (United States)

    Gloger, Oliver; Bülow, Robin; Tönnies, Klaus; Völzke, Henry

    2017-11-24

    We aimed to develop the first fully automated 3D gallbladder segmentation approach to perform volumetric analysis in volume data of magnetic resonance (MR) cholangiopancreatography (MRCP) sequences. Volumetric gallbladder analysis is performed for non-contrast-enhanced and secretin-enhanced MRCP sequences. Native and secretin-enhanced MRCP volume data were produced with a 1.5-T MR system. Images of coronal maximum intensity projections (MIP) are used to automatically compute 2D characteristic shape features of the gallbladder in the MIP images. A gallbladder shape space is generated to derive 3D gallbladder shape features, which are then combined with 2D gallbladder shape features in a support vector machine approach to detect gallbladder regions in MRCP volume data. A region-based level set approach is used for fine segmentation. Volumetric analysis is performed for both sequences to calculate gallbladder volume differences between both sequences. The approach presented achieves segmentation results with mean Dice coefficients of 0.917 in non-contrast-enhanced sequences and 0.904 in secretin-enhanced sequences. This is the first approach developed to detect and segment gallbladders in MR-based volume data automatically in both sequences. It can be used to perform gallbladder volume determination in epidemiological studies and to detect abnormal gallbladder volumes or shapes. The positive volume differences between both sequences may indicate the quantity of the pancreatobiliary reflux.

  6. Role of graft oversizing in the fixation strength of barbed endovascular grafts.

    Science.gov (United States)

    Kratzberg, Jarin A; Golzarian, Jafar; Raghavan, Madhavan L

    2009-06-01

    The role of endovascular graft oversizing on risk of distal graft migration following endovascular aneurysm repair for abdominal aortic aneurysm is poorly understood. A controlled in vitro investigation of the role of oversizing in graft-aorta attachment strength for endovascular grafts (EVGs) with barbs was performed. Barbed stent grafts (N = 20) with controlled graft oversizing varying from 4-45% were fabricated while maintaining other design variables unchanged. A flow loop with physiological flow characteristics and a biosynthetic aortic aneurysm phantom (synthetic aneurysm model with a bovine aortic neck) were developed. The stent grafts were deployed into the aortic neck of the bio-synthetic aortic aneurysm phantom under realistic flow conditions. Computed tomography imaging of the graft-aorta complex was used to document attachment characteristics such as graft apposition, number of barbs penetrated, and penetration depth and angle. The strength of graft attachment to the aortic neck was assessed using mechanical pullout testing. Stent grafts were categorized into four groups based on oversizing: 4-10%; 11-20%; 21-30%; and greater than 30% oversizing. Pullout force, a measure of post-deployment fixation strength was not different between 4-10% (6.23 +/- 1.90 N), 11-20% (6.25 +/- 1.84 N) and 20-30% (5.85 +/- 1.89 N) groups, but significantly lower for the group with greater than 30% oversizing (3.67 +/- 1.41 N). Increasing oversizing caused a proportional decrease in the number of barbs penetrating the aortic wall (correlation = -0.83). Of the 14 barbs available in the stent graft, 89% of the barbs (12.5 of 14 on average) penetrated the aortic wall in the 4-10% oversizing group while only 38% (5.25 of 14) did for the greater than 30% group (P barb penetration were found to be positively correlated to pullout force. Greater than 30% graft oversizing affects both barb penetration and graft apposition adversely resulting in a low pullout force in this in vitro

  7. Coronary artery bypass graft imaging using ECG-gated multislice computed tomography: Comparison with catheter angiography

    International Nuclear Information System (INIS)

    Moore, R.K.G.; Sampson, C.; MacDonald, S.; Moynahan, C.; Groves, D.; Chester, M.R.

    2005-01-01

    AIM: To compare the value of multislice computerized tomography (MSCT) in imaging coronary artery bypass grafts (CABGs) by direct quantitative comparison with standard invasive angiography. METHODS: Using MSCT, 50 consecutive patients who had previously undergone CABG surgery and had recently undergone invasive angiography for recurrent angina pectoris, were studied further using MSCT after intravenous injection of non-ionic contrast agent; cardiac imaging was performed during a single breath-hold. Graft anatomy was quantified, using both quantitative coronary angiography (QCA) and MSCT, by different investigators blinded to each other. Reproducibility was quantified using the standard error of the measurement expressed as a percentage in log-transformed values (CV%) and intraclass correlation (ICC). RESULTS: All 150 grafts were imaged using MSCT; only 4 patent grafts were not imaged using selective angiography. Good agreement was achieved between MSCT and QCA on assessment of proximal anastomoses (CV% 25.2, ICC 0.84), mid-vessel luminal diameter (CV% 15.5, ICC 0.91) and aneurysmal dilations (CV% 14.3). Reasonable agreement was reached on assessment of distal anastomoses (CV% 26.7, ICC 0.66) and categorization of distal run-off (ICC 0.73). Good agreement was observed for stenoses of over 50% luminal loss (CV% 8.7, ICC 0.97) but agreement on assessment of less severe lesions was poor (CV% 208.7, ICC 0.51). CONCLUSION: This study demonstrates that CABGs can be quantitatively evaluated using MSCT, and that significant lesions present in all CABG segments can be reliably identified. Agreement between MSCT and QCA for lesions of less than 50% luminal loss was poor

  8. Coronary artery bypass graft imaging using ECG-gated multislice computed tomography: Comparison with catheter angiography

    Energy Technology Data Exchange (ETDEWEB)

    Moore, R.K.G. [Cardiothoracic Centre, Liverpool (United Kingdom)]. E-mail: moore@roger.go-legend.net; Sampson, C. [Cardiothoracic Centre, Liverpool (United Kingdom); MacDonald, S. [Cardiothoracic Centre, Liverpool (United Kingdom); Moynahan, C. [Cardiothoracic Centre, Liverpool (United Kingdom); Groves, D. [National Refractory Angina Centre, Liverpool (United Kingdom); Chester, M.R. [National Refractory Angina Centre, Liverpool (United Kingdom)

    2005-09-01

    AIM: To compare the value of multislice computerized tomography (MSCT) in imaging coronary artery bypass grafts (CABGs) by direct quantitative comparison with standard invasive angiography. METHODS: Using MSCT, 50 consecutive patients who had previously undergone CABG surgery and had recently undergone invasive angiography for recurrent angina pectoris, were studied further using MSCT after intravenous injection of non-ionic contrast agent; cardiac imaging was performed during a single breath-hold. Graft anatomy was quantified, using both quantitative coronary angiography (QCA) and MSCT, by different investigators blinded to each other. Reproducibility was quantified using the standard error of the measurement expressed as a percentage in log-transformed values (CV%) and intraclass correlation (ICC). RESULTS: All 150 grafts were imaged using MSCT; only 4 patent grafts were not imaged using selective angiography. Good agreement was achieved between MSCT and QCA on assessment of proximal anastomoses (CV% 25.2, ICC 0.84), mid-vessel luminal diameter (CV% 15.5, ICC 0.91) and aneurysmal dilations (CV% 14.3). Reasonable agreement was reached on assessment of distal anastomoses (CV% 26.7, ICC 0.66) and categorization of distal run-off (ICC 0.73). Good agreement was observed for stenoses of over 50% luminal loss (CV% 8.7, ICC 0.97) but agreement on assessment of less severe lesions was poor (CV% 208.7, ICC 0.51). CONCLUSION: This study demonstrates that CABGs can be quantitatively evaluated using MSCT, and that significant lesions present in all CABG segments can be reliably identified. Agreement between MSCT and QCA for lesions of less than 50% luminal loss was poor.

  9. Chronologic changes of free fat graft in rabbit using CT

    International Nuclear Information System (INIS)

    Kondo, Norihiro; Kurita, Kenichi; Yajima, Tetsuya; Izumi, Masahiro

    2008-01-01

    Free fat grafts are now used for preventing osteal readhesion, filling dead space, and protecting grafted nerves and vessels. However, it is reported that grafted fat tissue is unstable resulting in high risk of cicatrization and infection. We grafted free fat to a rabbit's back and observed the chronologic change using CT. Ten adult male Japanese white rabbits (3.5 kg) were used. In five rabbits, fat tissue was obtained from the back under general anaesthesia, and transplanted into the back about 50 mm posterior from the donor site. CT was taken in the fixed scan condition five times (preoperation, immediate postoperation, postoperative 1-month, 2-month, and 3-month). In the remaining five rabbits, only CT scan was taken three times as a control. It was observed that we compared preoperative fat volume with the postoperative volume using RealINTAGE. Grafted fat tissue decreased postoperatively at 1-month and completely disappeared at 3-months. We were able to prove that CT scan is effective to observe the chronologic change of grafted fat tissue. Techniques of tissue engineering are necessary for survival of grafted fat tissue. (author)

  10. Inferior tendon graft to bone tunnel healing at the tibia compared to that at the femur after anterior cruciate ligament reconstruction

    International Nuclear Information System (INIS)

    Lui, P.P.Y.; Ho, G.; Shum, W.T.; Lee, Y.W.; Ho, P.Y.; Lo, W.N.; Lo, C.K.

    2010-01-01

    Tunnel widening after anterior cruciate ligament (ACL) reconstruction (ACLR) is commonly reported without a clear understanding of the mechanism. This study aimed to quantify the spatiotemporal change of the newly formed bone mass, bone tunnel diameter, and area along both bone tunnels using micro-computed tomography (μCT) and correlated the result with histology. ACLR was performed in 24 rabbits. At baseline and weeks 2, 6, and 12, the juxta-articular, middle, and exit segments of both tunnels were harvested for μCT and histological evaluation. μCT and histology revealed significant bone tunnel and graft-bone tunnel healing, respectively, only at week 6 after reconstruction. Despite this, the mean tunnel diameter and area remained relatively unchanged with time. The newly formed bone mass [new bone volume/total bone volume (BV/TV) ratio] and its bone mineral density (BMD) were both higher, whereas the mean tunnel diameter and area were significantly smaller at the femoral tunnel compared to those at the tibial tunnel at weeks 6 and 12 and at week 12, respectively. These were consistent with histological findings, which showed inferior graft remodeling and integration at the tibial tunnel at weeks 6 and 12. The BV/TV increased, whereas the mean tunnel diameter and area decreased toward the exit segment of both tunnels. However, whereas better histological healing occurred at the femoral exit segment, poorer graft remodeling and Sharpey's fiber formation occurred at the tibial exit segment. Poor healing was observed during the initial 6 weeks, particularly that of the tibia, after ACLR. Bone resorption was rapid during healing, resulting in unchanged tunnel diameter and area with time. (author)

  11. Use of lymphokine-activated killer cells to prevent bone marrow graft rejection and lethal graft-vs-host disease

    International Nuclear Information System (INIS)

    Azuma, E.; Yamamoto, H.; Kaplan, J.

    1989-01-01

    Prompted by our recent finding that lymphokine-activated killer (LAK) cells mediate both veto and natural suppression, we tested the ability of adoptively transferred LAK cells to block two in vivo alloreactions which complicate bone marrow transplantation: resistance to transplanted allogeneic bone marrow cells, and lethal graft-vs-host disease. Adoptive transfer of either donor type B6D2 or recipient-type B6 lymphokine-activated bone marrow cells, cells found to have strong LAK activity, abrogated or inhibited the resistance of irradiated B6 mice to both B6D2 marrow and third party-unrelated C3H marrow as measured by CFU in spleen on day 7. The ability of lymphokine-activated bone marrow cells to abrogate allogeneic resistance was eliminated by C lysis depletion of cells expressing asialo-GM1, NK1.1, and, to a variable degree, Thy-1, but not by depletion of cells expressing Lyt-2, indicating that the responsible cells had a LAK cell phenotype. Similar findings were obtained by using splenic LAK cells generated by 3 to 7 days of culture with rIL-2. Demonstration that allogeneic resistance could be blocked by a cloned LAK cell line provided direct evidence that LAK cells inhibit allogeneic resistance. In addition to inhibiting allogeneic resistance, adoptively transferred recipient-type LAK cells prevented lethal graft-vs-host disease, and permitted long term engraftment of allogeneic marrow. Irradiation prevented LAK cell inhibition of both allogeneic resistance and lethal graft-vs-host disease. These findings suggest that adoptive immunotherapy with LAK cells may prove useful in preventing graft rejection and graft-versus-host disease in human bone marrow transplant recipients

  12. Endovascular stent-graft management of thoracic aortic diseases

    International Nuclear Information System (INIS)

    Dake, Michael D.

    2001-01-01

    The traditional standard therapy for descending thoracic aortic aneurysm (TAA) is open operative repair with graft replacement of the diseased aortic segment. Despite important advances in surgical techniques, anesthetic management, and post-operative care over the last 30 years, the mortality and morbidity of surgery remains considerable, especially in patients at high risk for thoracotomy because of coexisting severe cardiopulmonary abnormalities or other medical diseases. The advent of endovascular stent-graft technology provides an alternative to open surgery for selected patients with TAA. The initial experience suggests that stent-graft therapy potentially may reduce the operative risk, hospital stay and procedural expenses of TAA repair. These potential benefits are especially attractive for patients at high risk for open TAA repair. Current results of endovascular TAA therapy document operative mortalities of between 0 and 4%, aneurysm thrombosis in 90 and 100% of cases, and paraplegia as a complication in 0 and 1.6% of patients. The early success of stent-graft repair of TAA has fostered the application of these devices for the management of a wide variety of thoracic aortic pathologies, including acute and chronic dissection, intramural hematoma, penetrating ulcer, traumatic injuries, and other diseases. The results of prospective controlled trials that compare the outcomes of stent-graft therapy with those of surgical treatment in patients with specific types of aortic disease are anxiously awaited before recommendations regarding the general use of these new devices can be made with confidence

  13. Calibrated Full-Waveform Airborne Laser Scanning for 3D Object Segmentation

    Directory of Open Access Journals (Sweden)

    Fanar M. Abed

    2014-05-01

    Full Text Available Segmentation of urban features is considered a major research challenge in the fields of photogrammetry and remote sensing. However, the dense datasets now readily available through airborne laser scanning (ALS offer increased potential for 3D object segmentation. Such potential is further augmented by the availability of full-waveform (FWF ALS data. FWF ALS has demonstrated enhanced performance in segmentation and classification through the additional physical observables which can be provided alongside standard geometric information. However, use of FWF information is not recommended without prior radiometric calibration, taking into account all parameters affecting the backscatter energy. This paper reports the implementation of a radiometric calibration workflow for FWF ALS data, and demonstrates how the resultant FWF information can be used to improve segmentation of an urban area. The developed segmentation algorithm presents a novel approach which uses the calibrated backscatter cross-section as a weighting function to estimate the segmentation similarity measure. The normal vector and the local Euclidian distance are used as criteria to segment the point clouds through a region growing approach. The paper demonstrates the potential to enhance 3D object segmentation in urban areas by integrating the FWF physical backscattered energy alongside geometric information. The method is demonstrated through application to an interest area sampled from a relatively dense FWF ALS dataset. The results are assessed through comparison to those delivered from utilising only geometric information. Validation against a manual segmentation demonstrates a successful automatic implementation, achieving a segmentation accuracy of 82%, and out-performs a purely geometric approach.

  14. Ilizarov bone transport versus fibular graft for reconstruction of tibial bone defects in children.

    Science.gov (United States)

    Abdelkhalek, Mostafa; El-Alfy, Barakat; Ali, Ayman M

    2016-11-01

    The aim of this study was to compare the results of treatment of segmental tibial defects in the pediatric age group using an Ilizarov external fixator versus a nonvascularized fibular bone graft. This study included 24 patients (age range from 5.5 to 15 years) with tibial bone defects: 13 patients were treated with bone transport (BT) and 11 patients were treated with a nonvascularized fibular graft (FG). The outcome parameters were bone results (union, deformity, infection, leg-length discrepancy) and functional results: external fixation index and external fixation time. In group A (BT), one patient developed refracture at the regenerate site, whereas, in group B (FG), after removal of the external fixator, one of the FGs developed a stress fracture. The external fixator time in group A was 10.7 months (range 8-14.5) versus 7.8 months (range 4-11.5 months) in group B (FG). In group A (BT), one patient had a limb-length discrepancy (LLD), whereas, in group B (FG), three patients had LLD. The functional and bone results of the Ilizarov BT technique were excellent in 23.1 and 30.8%, good in 38.5 and 46.2, fair in 30.8 and 15.4, and poor in 7.6 and 7.6%, respectively. The poor functional result was related to the poor bone result because of prolonged external fixator time resulting in significant pain, limited ankle motion, whereas the functional and bone results of fibular grafting were excellent in 9.1 and 18.2%, good in 63.6 and 45.5%, fair in 18.2 and 27.2%, and poor in 9.1 and 9.1%, respectively. Segmental tibial defects can be effectively treated with both methods. The FG method provides satisfactory results, with early removal of the external fixator. However, it had a limitation in patients with severe infection and those with LLD. Also, it requires a long duration of limb bracing until adequate hypertrophy of the graft. The Ilizarov method has the advantages of early weight bearing, treatment of postinfection bone defect in a one-stage surgery, and the

  15. Reproducibility of myelin content-based human habenula segmentation at 3 Tesla.

    Science.gov (United States)

    Kim, Joo-Won; Naidich, Thomas P; Joseph, Joshmi; Nair, Divya; Glasser, Matthew F; O'halloran, Rafael; Doucet, Gaelle E; Lee, Won Hee; Krinsky, Hannah; Paulino, Alejandro; Glahn, David C; Anticevic, Alan; Frangou, Sophia; Xu, Junqian

    2018-03-26

    In vivo morphological study of the human habenula, a pair of small epithalamic nuclei adjacent to the dorsomedial thalamus, has recently gained significant interest for its role in reward and aversion processing. However, segmenting the habenula from in vivo magnetic resonance imaging (MRI) is challenging due to the habenula's small size and low anatomical contrast. Although manual and semi-automated habenula segmentation methods have been reported, the test-retest reproducibility of the segmented habenula volume and the consistency of the boundaries of habenula segmentation have not been investigated. In this study, we evaluated the intra- and inter-site reproducibility of in vivo human habenula segmentation from 3T MRI (0.7-0.8 mm isotropic resolution) using our previously proposed semi-automated myelin contrast-based method and its fully-automated version, as well as a previously published manual geometry-based method. The habenula segmentation using our semi-automated method showed consistent boundary definition (high Dice coefficient, low mean distance, and moderate Hausdorff distance) and reproducible volume measurement (low coefficient of variation). Furthermore, the habenula boundary in our semi-automated segmentation from 3T MRI agreed well with that in the manual segmentation from 7T MRI (0.5 mm isotropic resolution) of the same subjects. Overall, our proposed semi-automated habenula segmentation showed reliable and reproducible habenula localization, while its fully-automated version offers an efficient way for large sample analysis. © 2018 Wiley Periodicals, Inc.

  16. Deep learning of the sectional appearances of 3D CT images for anatomical structure segmentation based on an FCN voting method.

    Science.gov (United States)

    Zhou, Xiangrong; Takayama, Ryosuke; Wang, Song; Hara, Takeshi; Fujita, Hiroshi

    2017-10-01

    We propose a single network trained by pixel-to-label deep learning to address the general issue of automatic multiple organ segmentation in three-dimensional (3D) computed tomography (CT) images. Our method can be described as a voxel-wise multiple-class classification scheme for automatically assigning labels to each pixel/voxel in a 2D/3D CT image. We simplify the segmentation algorithms of anatomical structures (including multiple organs) in a CT image (generally in 3D) to a majority voting scheme over the semantic segmentation of multiple 2D slices drawn from different viewpoints with redundancy. The proposed method inherits the spirit of fully convolutional networks (FCNs) that consist of "convolution" and "deconvolution" layers for 2D semantic image segmentation, and expands the core structure with 3D-2D-3D transformations to adapt to 3D CT image segmentation. All parameters in the proposed network are trained pixel-to-label from a small number of CT cases with human annotations as the ground truth. The proposed network naturally fulfills the requirements of multiple organ segmentations in CT cases of different sizes that cover arbitrary scan regions without any adjustment. The proposed network was trained and validated using the simultaneous segmentation of 19 anatomical structures in the human torso, including 17 major organs and two special regions (lumen and content inside of stomach). Some of these structures have never been reported in previous research on CT segmentation. A database consisting of 240 (95% for training and 5% for testing) 3D CT scans, together with their manually annotated ground-truth segmentations, was used in our experiments. The results show that the 19 structures of interest were segmented with acceptable accuracy (88.1% and 87.9% voxels in the training and testing datasets, respectively, were labeled correctly) against the ground truth. We propose a single network based on pixel-to-label deep learning to address the challenging

  17. Effect of Grafting Method, Graft Cover and Foliar Spray of some Mineral Elements on Persian Walnut Graft-take and Winter Survival Rate

    Directory of Open Access Journals (Sweden)

    Reza Rezaee

    2017-09-01

    Full Text Available Introduction: Persian walnut (Juglans regia L. is an important nut crop in Iran and many parts of the world. One of the major challenges of growing walnut is planting of non-grafted walnut trees in orchards, which leads to the reduction of yield, quality and productivity of walnut orchards. Compared to the other fruit trees, walnut grafting is difficult and even newly grafted walnut seedlings are vulnerable to fall or winter frost chilling, so that most of the seedlings are lost after subjecting to the cold winter. There are a few studies reporting successful grafting in outdoor conditions, however, final grafting take after winter has been usually ignored. Hence, increased walnut grafting success and improved tree growth after grafting through foliar nutrient application may lead to increased tolerance of chilling. Therefore, main goals of this research were to investigate the effect of some graft covers and role of foliar spray of calcium, boron and zinc on the reduction of frost damage in newly grafted seedlings under outdoor conditions. Materials and methods: This research was conducted at agricultural research station, Khoy city, west Azerbaijan province, during 2012-2014. In the first experiment, three methods of grafting including cleft, bark and V-shaped, and two kinds of graft covers including moist sawdust and superabsorbent plus cotton wool were investigated in terms of grafting success and quality of seedlings. In the second experiment, effect of the three above-mentioned grafting methods and two levels of foliar spray including sequential spray of Ca (4 ppm, B and Zn (2% (3 times during growth season and control (no spray were studied in terms of frost damage. The experiments conducted in factorial based on randomized complete block design with 10 trees in each plot. Data were collected 45 days after grafting take, final grafting take after one winter, subsequent scion growth length and diameter and concentration of Ca, B and Zn in

  18. Interleaved 3D-CNNs for joint segmentation of small-volume structures in head and neck CT images.

    Science.gov (United States)

    Ren, Xuhua; Xiang, Lei; Nie, Dong; Shao, Yeqin; Zhang, Huan; Shen, Dinggang; Wang, Qian

    2018-02-26

    Accurate 3D image segmentation is a crucial step in radiation therapy planning of head and neck tumors. These segmentation results are currently obtained by manual outlining of tissues, which is a tedious and time-consuming procedure. Automatic segmentation provides an alternative solution, which, however, is often difficult for small tissues (i.e., chiasm and optic nerves in head and neck CT images) because of their small volumes and highly diverse appearance/shape information. In this work, we propose to interleave multiple 3D Convolutional Neural Networks (3D-CNNs) to attain automatic segmentation of small tissues in head and neck CT images. A 3D-CNN was designed to segment each structure of interest. To make full use of the image appearance information, multiscale patches are extracted to describe the center voxel under consideration and then input to the CNN architecture. Next, as neighboring tissues are often highly related in the physiological and anatomical perspectives, we interleave the CNNs designated for the individual tissues. In this way, the tentative segmentation result of a specific tissue can contribute to refine the segmentations of other neighboring tissues. Finally, as more CNNs are interleaved and cascaded, a complex network of CNNs can be derived, such that all tissues can be jointly segmented and iteratively refined. Our method was validated on a set of 48 CT images, obtained from the Medical Image Computing and Computer Assisted Intervention (MICCAI) Challenge 2015. The Dice coefficient (DC) and the 95% Hausdorff Distance (95HD) are computed to measure the accuracy of the segmentation results. The proposed method achieves higher segmentation accuracy (with the average DC: 0.58 ± 0.17 for optic chiasm, and 0.71 ± 0.08 for optic nerve; 95HD: 2.81 ± 1.56 mm for optic chiasm, and 2.23 ± 0.90 mm for optic nerve) than the MICCAI challenge winner (with the average DC: 0.38 for optic chiasm, and 0.68 for optic nerve; 95HD: 3.48 for

  19. 3D segmentation of scintigraphic images with validation on realistic GATE simulations

    International Nuclear Information System (INIS)

    Burg, Samuel

    2011-01-01

    The objective of this thesis was to propose a new 3D segmentation method for scintigraphic imaging. The first part of the work was to simulate 3D volumes with known ground truth in order to validate a segmentation method over other. Monte-Carlo simulations were performed using the GATE software (Geant4 Application for Emission Tomography). For this, we characterized and modeled the gamma camera 'γ Imager' Biospace"T"M by comparing each measurement from a simulated acquisition to his real equivalent. The 'low level' segmentation tool that we have developed is based on a modeling of the levels of the image by probabilistic mixtures. Parameters estimation is done by an SEM algorithm (Stochastic Expectation Maximization). The 3D volume segmentation is achieved by an ICM algorithm (Iterative Conditional Mode). We compared the segmentation based on Gaussian and Poisson mixtures to segmentation by thresholding on the simulated volumes. This showed the relevance of the segmentations obtained using probabilistic mixtures, especially those obtained with Poisson mixtures. Those one has been used to segment real "1"8FDG PET images of the brain and to compute descriptive statistics of the different tissues. In order to obtain a 'high level' segmentation method and find anatomical structures (necrotic part or active part of a tumor, for example), we proposed a process based on the point processes formalism. A feasibility study has yielded very encouraging results. (author) [fr

  20. Distinct Biomarker Profiles in Ex Vivo T Cell Depletion Graft Manipulation Strategies: CD34+ Selection versus CD3+/19+ Depletion in Matched Sibling Allogeneic Peripheral Blood Stem Cell Transplantation.

    Science.gov (United States)

    Cantilena, Caroline R; Ito, Sawa; Tian, Xin; Jain, Prachi; Chinian, Fariba; Anandi, Prathima; Keyvanfar, Keyvan; Draper, Debbie; Koklanaris, Eleftheria; Hauffe, Sara; Superata, Jeanine; Stroncek, David; Muranski, Pawel; Barrett, A John; Battiwalla, Minoo

    2018-03-01

    Various approaches have been developed for ex vivo T cell depletion in allogeneic stem cell transplantation to prevent graft-versus-host disease (GVHD). Direct comparisons of T cell depletion strategies have not been well studied, however. We evaluated cellular and plasma biomarkers in 2 different graft manipulation strategies, CD3 + CD19 + cell depletion (CD3/19D) versus CD34 + selection (CD34S), and their associations with clinical outcomes. Identical conditions, including the myeloablative preparative regimen, HLA-identical sibling donor, GVHD prophylaxis, and graft source, were used in the 2 cohorts. Major clinical outcomes were similar in the 2 groups in terms of overall survival, nonrelapse mortality, and cumulative incidence of relapse; however, the cumulative incidence of acute GVHD trended to be higher in the CD3/19D cohort compared with the CD34S cohort. A distinct biomarker profile was noted in the CD3/19D cohort: higher levels of ST2, impaired Helios - FoxP3 + Treg reconstitution, and rapid reconstitution of naïve, Th2, and Th17 CD4 cells in the early post-transplantation period. In vitro graft replication studies confirmed that CD3/19D disproportionately depleted Tregs and other CD4 subset repertoires in the graft. This study confirms the utility of biomarker monitoring, which can be directly correlated with biological consequences and possible future therapeutic indications. Published by Elsevier Inc.

  1. Pretransplant IgA-Anti-Beta 2 Glycoprotein I Antibodies As a Predictor of Early Graft Thrombosis after Renal Transplantation in the Clinical Practice: A Multicenter and Prospective Study

    Directory of Open Access Journals (Sweden)

    Jose M. Morales

    2018-03-01

    Full Text Available BackgroundGraft thrombosis is a devastating complication after renal transplantation. We recently described the association of anti-beta-2-glycoprotein-I (IgA-ab2GP1 antibodies with early graft loss mainly caused by thrombosis in a monocenter study.MethodsMulticenter prospective observational cohort study.Setting and participantsSeven hundred forty patients from five hospitals of the Spanish Forum Renal Group transplanted from 2000 to 2002 were prospectively followed-up for 10 years.OutcomesEarly graft loss and graft loss by thrombosis.MeasurementsThe presence of IgA anti-B2GP1 antibodies in pretransplant serum was examined using the same methodology in all the patients.ResultsAt transplantation, 288 patients were positive for IgA-B2GP1 (39%, Group-1 and the remaining were negative (Group-2. Graft loss at 6 months was higher in Group-1 (12.5 vs. 4.2% p < 0.001, vessel thrombosis being the most frequent cause of early graft loss, especially in Group-1 (6.9 vs. 0.4% p < 0.001. IgA-aB2GP1 was the most important independent risk factor for graft thrombosis (hazard ratio: 13.83; 95% CI: 3.17–60.27, p < 0.001. Furthermore, the, presence of IgA-aB2GP1 was associated with early graft loss and delayed graft function. At 10 years, survival figures were also lower in Group-1: graft survival was lower compared with Group-2 (60.4 vs. 76.8%, p < 0.001. Mortality was significantly higher in Group-1 (19.8 vs. 12.2%, p = 0.005.LimitationsPatients were obtained during a 3-year period (1 January 2000–31 December 2002 and kidneys were only transplanted from brain-dead donors. Nowadays, the patients are older and the percentage of sensitized and retransplants is high.ConclusionIn a prospective observational multicenter study, we were able to corroborate that pretransplant presence of IgA-aB2GP1 was the main risk factor for graft thrombosis and early graft loss. Therefore, a prospective study is needed to evaluate the efficacy and safety

  2. Radiation-induced grafting of TMPM onto polypropylene

    International Nuclear Information System (INIS)

    Wang Huiliang; Li Hong; Chen Wenxiu

    1995-01-01

    The gamma radiation-induced graft copolymerization of 2,2,6,6-tetramethyl-4-piperidinyl-methacrylate (TMPM), a very effective hindered amine light stabilizer (HALS), onto polypropylene was investigated by simultaneous- irradiation technique. The various synthesis conditions on the graft content was studied. It was found that benzene, CCl 4 and petroleum ether are more effective than other solvents, the percent grafting reached 7.1% for benzene. The percent grafting is higher when graft copolymerization is carried out in argon atmosphere than those in air. For all the grafting copolymerization carried out in benzene and CCl 4 , percent grafting increase linearly from 1 to 5 Mrad and beyond 5 Mrad, a tendency to level off appeared. At a constant dose, the percent grafting was found to be higher at high dose rate until 228 rad/s. Percent grafting also increased continuously with increasing monomer concentration up to 2.85 mol/L, but significant increase in grafting was observed only up to 1.14 mol/L

  3. Oblique needle segmentation and tracking for 3D TRUS guided prostate brachytherapy

    International Nuclear Information System (INIS)

    Wei Zhouping; Gardi, Lori; Downey, Donal B.; Fenster, Aaron

    2005-01-01

    An algorithm was developed in order to segment and track brachytherapy needles inserted along oblique trajectories. Three-dimensional (3D) transrectal ultrasound (TRUS) images of the rigid rod simulating the needle inserted into the tissue-mimicking agar and chicken breast phantoms were obtained to test the accuracy of the algorithm under ideal conditions. Because the robot possesses high positioning and angulation accuracies, we used the robot as a ''gold standard,'' and compared the results of algorithm segmentation to the values measured by the robot. Our testing results showed that the accuracy of the needle segmentation algorithm depends on the needle insertion distance into the 3D TRUS image and the angulations with respect to the TRUS transducer, e.g., at a 10 deg. insertion anglulation in agar phantoms, the error of the algorithm in determining the needle tip position was less than 1 mm when the insertion distance was greater than 15 mm. Near real-time needle tracking was achieved by scanning a small volume containing the needle. Our tests also showed that, the segmentation time was less than 60 ms, and the scanning time was less than 1.2 s, when the insertion distance into the 3D TRUS image was less than 55 mm. In our needle tracking tests in chicken breast phantoms, the errors in determining the needle orientation were less than 2 deg. in robot yaw and 0.7 deg. in robot pitch orientations, for up to 20 deg. needle insertion angles with the TRUS transducer in the horizontal plane when the needle insertion distance was greater than 15 mm

  4. Functionalization of LDPE and mLLDPE via grafting trans-ethylene-1,2-dicarboxylic acid by reactive extrusion

    Directory of Open Access Journals (Sweden)

    2010-03-01

    Full Text Available An investigation was made of grafting trans-ethylene-1,2-dicarboxylic acid (TEDA onto metallocene-linear low-density polyethylene (mLLDPE and low-density polyethylene (LDPE in the course of reactive extrusion. The initiator was 1,3-bis-(tert-butyl-peroxyisopropylbenzene. The graft efficiency of TEDA has been shown to increase with increasing initiator concentration, irrespective of polyethylene type. The graft values for LDPE were higher than for mLLDPE over the initiator concentration range (0.05 to 0.4 wt%. The rheological properties of mLLDPE were found to undergo more tangible changes during functionalization than those of LDPE. These changes were caused by side reactions, mainly macromolecular crosslinking. It has been established that some carboxyl groups get transformed to anhydride groups in the grafted product. The concentration of end double bonds reduces, but intramolecular unsaturation in both polyethylenes increases. Data are presented on thermal and stress-strain (mechanical properties of virgin and functionalized polymers, as well as rheological and viscoelastic properties of their melts.

  5. Diazonium salt derivatives of osmium bipyridine complexes: Electrochemical grafting and characterisation of modified surfaces

    International Nuclear Information System (INIS)

    Garrett, David J.; Jenkins, Peter; Polson, Matthew I.J.; Leech, Donal; Baronian, Keith H.R.; Downard, Alison J.

    2011-01-01

    Osmium bipyridine complexes were directly grafted to carbon electrodes through electroreduction of the diazonium salts [Os(bpy-ph-N 2 + ) 3 ](PF 6 ) 5 (1) and [Os(bpy-ph-N 2 + ) 2 Cl 2 ](PF 6 ) 2 (2). Growth of the films was not self-limiting as is usually found for grafting from diazonium salts. It appears that electron hopping through the bipyridine ligands of the immobilised complexes enables film growth to continue at a constant rate during grafting by potential cycling. The surface concentrations of deposited films were measured electrochemically and the film thicknesses were measured by depth-profiling using the atomic force microscope. Films up to 42 nm thick were prepared with no evidence for slowing of film growth. The grafted films exhibited high stability when repetitively cycled through the Os 2+/3+ couple and electron transfer rate constants of 11.4 s -1 and 35.4 s -1 were measured in ACN and PBS, respectively, for the Os 2+/3+ couple of the film grafted from 1.

  6. [Vascular trombosis of renal graft: 9 cases].

    Science.gov (United States)

    Kaaroud, Hayet; Béji, Soumaya; Ben Hamida, Fethi; Rais, Lamia; Ben Abdallah, Taieb; El Younsi, Fethi; Ben Moussa, Fatma; Abderrahim, Ezzedine; Bardi, Rafika; Ayed, Khaled; Chebil, Mohamed; Kheder, Adel

    2008-04-01

    Allograft renal thrombosis can occur in 1 to 6% of cases. Many predisposing factors has been identified especially alteration of coagulation. We analyzed in this study frequency and predisposing factors of renal graft thrombosis. We report a retrospective study including 319 renal transplant recipients. Nine patients (2.8%) presented veinous graft thrombosis in 5 cases and arterial thombosis in 4 cases. There were 6 men and 3 women aged of 30.6 years meanly (10-56) which developed the thrombosis 6 days (1-48) after the transplantation. All patients were detransplanted after 16.2 days and 1 patient died. Thrombosis constitute an important cause of graft loss. A perfect surgical technic and prophylactic treatment in high risk patients are necessary to reduce this complication.

  7. Effect of 2,4-D on content of abscisic and 3-indoleacetic acids in corn coleoptile segments

    International Nuclear Information System (INIS)

    Zemskaya, V.A.; Kalibernaya, Z.V.; Verenchikov, S.P.; Rakitin, L.Yu.; Sadovskaya, V.L.

    1989-01-01

    The authors studied the influence of growth-stimulating (10 -4 M), growth-inhibiting (3 x 10-3 M), lethal (7.5 x 10 -3 M) concentrations of 2,4-D on content of ABA and IAA, as well as on entry and conversion of [1- 14 C]-2,4-D, in corn (Zea mays L.) coleoptile segments. Increase of ABA content was observed at 6 h after influence of a stimulating dose of 2,4-D, an inhibiting dose caused no changes of ABA content, and a lethal dose led to decline of its level. The content of IAA declined sharply at all of the studied 2,4-D concentrations. This effect was accompanied neither by intensification of IAA-oxidase activity nor by increase in the content of bound forms of IAA. Metabolism of 2,4-D was realized mainly via hydroxylation of the benzene ring with subsequent hydroxylation, as well as by means of glucose ester formation. These processes transpired most intensively in the case of a stimulating dose of 2,4-D and less intensively in the case of an inhibiting dose and especially in that of a lethal dose

  8. Early and long-term outcomes of coronary artery bypass grafting in patients with acute coronary syndrome versus stable angina pectoris.

    Science.gov (United States)

    Fukui, Toshihiro; Tabata, Minoru; Morita, Satoshi; Takanashi, Shuichiro

    2013-06-01

    The aim of the present study was to determine the early and long-term outcomes of coronary artery bypass grafting in patients with acute coronary syndrome and stable angina pectoris. From September 2004 to September 2011, 382 patients with acute coronary syndrome (unstable angina pectoris and non-ST-segment elevation myocardial infarction) and 851 patients with stable angina pectoris underwent first-time isolated coronary artery bypass grafting at our institute. The early and long-term outcomes were compared between the 2 groups. Patients with acute coronary syndrome were older, were more likely to be women, had a smaller body surface area, and were more likely to have left main coronary artery disease. In both groups, bilateral internal thoracic artery grafts were used in approximately 89% of the patients, and off-pump techniques in approximately 97% of the patients. The acute coronary syndrome group had a greater operative death rate (2.6% vs 0.1%) and a greater incidence of low output syndrome (3.1% vs 1.2%) and hemodialysis requirement (2.9% vs 1.1%). Multivariate regression analysis demonstrated that age, acute coronary syndrome, lower ejection fraction, and higher creatinine level before surgery were independent predictors of operative death. However, among the hospital survivors, no differences were seen in freedom from all death (85.4% ± 2.5% vs 87.7% ± 2.0%), cardiac death (97.4% ± 0.9% vs 96.5% ± 0.9%), or major adverse cardiac and cerebrovascular events (78.0% ± 2.9% vs 78.1% ± 2.3%) at 7 years between the patients with acute coronary syndrome and stable angina pectoris. Although acute coronary syndrome is an independent predictor of early mortality in patients undergoing coronary artery bypass grafting, the long-term outcomes after surgery were similar between patients with acute coronary syndrome and stable angina pectoris who survived the early postoperative period. Copyright © 2013 The American Association for Thoracic Surgery. Published by

  9. Graft-Sparing Strategy for Thoracic Prosthetic Graft Infection.

    Science.gov (United States)

    Uchino, Gaku; Yoshida, Takeshi; Kakii, Bunpachi; Furui, Masato

    2018-04-01

     Thoracic prosthetic graft infection is a rare but serious complication with no standard management. We reported our surgical experience on graft-sparing strategy for thoracic prosthetic graft infection.  This study included patients who underwent graft-sparing surgery for thoracic prosthetic graft infection at Matsubara Tokushukai Hospital in Japan from January 2000 to October 2017.  There were 17 patients included in the analyses, with a mean age at surgery of 71.0 ± 10.5 years; 11 were men. In-hospital mortality was observed in five patients (29.4%).  Graft-sparing surgery for thoracic prosthetic graft infection is an alternative option particularly for early graft infection after hemiarch replacement. Georg Thieme Verlag KG Stuttgart · New York.

  10. Comparative study of navigated versus freehand osteochondral graft transplantation of the knee.

    Science.gov (United States)

    Koulalis, Dimitrios; Di Benedetto, Paolo; Citak, Mustafa; O'Loughlin, Padhraig; Pearle, Andrew D; Kendoff, Daniel O

    2009-04-01

    Osteochondral lesions are a common sports-related injury for which osteochondral grafting, including mosaicplasty, is an established treatment. Computer navigation has been gaining popularity in orthopaedic surgery to improve accuracy and precision. Navigation improves angle and depth matching during harvest and placement of osteochondral grafts compared with conventional freehand open technique. Controlled laboratory study. Three cadaveric knees were used. Reference markers were attached to the femur, tibia, and donor/recipient site guides. Fifteen osteochondral grafts were harvested and inserted into recipient sites with computer navigation, and 15 similar grafts were inserted freehand. The angles of graft removal and placement as well as surface congruity (graft depth) were calculated for each surgical group. The mean harvesting angle at the donor site using navigation was 4 degrees (standard deviation, 2.3 degrees ; range, 1 degrees -9 degrees ) versus 12 degrees (standard deviation, 5.5 degrees ; range, 5 degrees -24 degrees ) using freehand technique (P standard deviation, 2.1 degrees ; range, 0 degrees -9 degrees ) versus 10.7 degrees (standard deviation, 4.9 degrees ; range, 2 degrees -17 degrees ) in freehand (P standard deviation, 2.0 degrees ; range, 1 degrees -9 degrees ) versus 10.6 degrees (standard deviation, 4.4 degrees ; range, 3 degrees -17 degrees ) with freehand technique (P = .0001). The mean height of plug protrusion under navigation was 0.3 mm (standard deviation, 0.2 mm; range, 0-0.6 mm) versus 0.5 mm (standard deviation, 0.3 mm; range, 0.2-1.1 mm) using a freehand technique (P = .0034). Significantly greater accuracy and precision were observed in harvesting and placement of the osteochondral grafts in the navigated procedures. Clinical studies are needed to establish a benefit in vivo. Improvement in the osteochondral harvest and placement is desirable to optimize clinical outcomes. Navigation shows great potential to improve both harvest

  11. PMMA-g-OEtOx Graft Copolymers: Influence of Grafting Degree and Side Chain Length on the Conformation in Aqueous Solution

    Directory of Open Access Journals (Sweden)

    Irina Muljajew

    2018-03-01

    Full Text Available Depending on the degree of grafting (DG and the side chain degree of polymerization (DP, graft copolymers may feature properties similar to statistical copolymers or to block copolymers. This issue is approached by studying aqueous solutions of PMMA-g-OEtOx graft copolymers comprising a hydrophobic poly(methyl methacrylate (PMMA backbone and hydrophilic oligo(2-ethyl-2-oxazoline (OEtOx side chains. The graft copolymers were synthesized via reversible addition-fragmentation chain transfer (RAFT copolymerization of methyl methacrylate (MMA and OEtOx-methacrylate macromonomers of varying DP. All aqueous solutions of PMMA-g-OEtOx (9% ≤ DG ≤ 34%; 5 ≤ side chain DP ≤ 24 revealed lower critical solution temperature behavior. The graft copolymer architecture significantly influenced the aggregation behavior, the conformation in aqueous solution and the coil to globule transition, as verified by means of turbidimetry, dynamic light scattering, nuclear magnetic resonance spectroscopy, and analytical ultracentrifugation. The aggregation behavior of graft copolymers with a side chain DP of 5 was significantly affected by small variations of the DG, occasionally forming mesoglobules above the cloud point temperature (Tcp, which was around human body temperature. On the other hand, PMMA-g-OEtOx with elongated side chains assembled into well-defined structures below the Tcp (apparent aggregation number (Nagg = 10 that were able to solubilize Disperse Orange 3. The thermoresponsive behavior of aqueous solutions thus resembled that of micelles comprising a poly(2-ethyl-2-oxazoline (PEtOx shell (Tcp > 60 °C.

  12. An Ensemble of 2D Convolutional Neural Networks for Tumor Segmentation

    DEFF Research Database (Denmark)

    Lyksborg, Mark; Puonti, Oula; Agn, Mikael

    2015-01-01

    Accurate tumor segmentation plays an important role in radiosurgery planning and the assessment of radiotherapy treatment efficacy. In this paper we propose a method combining an ensemble of 2D convolutional neural networks for doing a volumetric segmentation of magnetic resonance images....... The segmentation is done in three steps; first the full tumor region, is segmented from the background by a voxel-wise merging of the decisions of three networks learned from three orthogonal planes, next the segmentation is refined using a cellular automaton-based seed growing method known as growcut. Finally......, within-tumor sub-regions are segmented using an additional ensemble of networks trained for the task. We demonstrate the method on the MICCAI Brain Tumor Segmentation Challenge dataset of 2014, and show improved segmentation accuracy compared to an axially trained 2D network and an ensemble segmentation...

  13. Electrochemical Grafting of Graphene Nano Platelets with Aryl Diazonium Salts.

    Science.gov (United States)

    Qiu, Zhipeng; Yu, Jun; Yan, Peng; Wang, Zhijie; Wan, Qijin; Yang, Nianjun

    2016-10-26

    To vary interfacial properties, electrochemical grafting of graphene nano platelets (GNP) with 3,5-dichlorophenyl diazonium tetrafluoroborate (aryl-Cl) and 4-nitrobenzene diazonium tetrafluoroborate (aryl-NO 2 ) was realized in a potentiodynamic mode. The covalently bonded aryl layers on GNP were characterized using atomic force microscopy and X-ray photoelectron spectroscopy. Electrochemical conversion of aryl-NO 2 into aryl-NH 2 was conducted. The voltammetric and impedance behavior of negatively and positively charged redox probes (Fe(CN) 6 3-/4- and Ru(NH 3 ) 6 2+/3+ ) on three kinds of aryl layers grafted on GNP reveal that their interfacial properties are determined by the charge states of redox probes and reactive terminal groups (-Cl, -NO 2 , -NH 2 ) in aryl layers. On aryl-Cl and aryl-NH 2 garted GNP, selective and sensitive monitoring of positively charged lead ions as well as negatively charged nitrite and sulfite ions was achieved, respectively. Such a grafting procedure is thus a perfect way to design and control interfacial properties of graphene.

  14. Super-Segments Based Classification of 3D Urban Street Scenes

    Directory of Open Access Journals (Sweden)

    Yu Zhou

    2012-12-01

    Full Text Available We address the problem of classifying 3D point clouds: given 3D urban street scenes gathered by a lidar sensor, we wish to assign a class label to every point. This work is a key step toward realizing applications in robots and cars, for example. In this paper, we present a novel approach to the classification of 3D urban scenes based on super-segments, which are generated from point clouds by two stages of segmentation: a clustering stage and a grouping stage. Then, six effective normal and dimension features that vary with object class are extracted at the super-segment level for training some general classifiers. We evaluate our method both quantitatively and qualitatively using the challenging Velodyne lidar data set. The results show that by only using normal and dimension features we can achieve better recognition than can be achieved with high-dimensional shape descriptors. We also evaluate the adopting of the MRF framework in our approach, but the experimental results indicate that thisbarely improved the accuracy of the classified results due to the sparse property of the super-segments.

  15. One-stage treatment and reconstruction of Gustilo Type III open tibial shaft fractures with a vascularized fibular osteoseptocutaneous flap graft.

    Science.gov (United States)

    Zhen, Ping; Hu, Yun-Yu; Luo, Zhuo-Jing; Liu, Xing-Yan; Lu, Hao; Li, Xu-Sheng

    2010-12-01

    This study evaluated the usefulness of a single-stage, free-fibular vascularized osteoseptocutaneous flap transfer for Type III open tibial shaft fractures with segmental bone loss for the reconstruction of combined bone and soft tissue defects. Nonrandomized retrospective study. University Level I trauma center. All Gustilo Type III open tibial shaft fractures with segmental bone loss that were treated at one institution between 2000 and 2007 were identified from a trauma registry. The study group consisted of 28 patients with Type III open tibial fractures: 27 were Gustilo-Anderson Type IIIB and one was Grade IIIC. The cause of tibial injury included eight industrial accidents, seven motor vehicle accidents, five crushing injuries caused by heavy objects, five falls from a height, and three motorcycle crashes. The lengths of the preoperative segmental tibial bone loss ranged from 9 to 17 cm and the size of the associated soft tissue defects ranged from 8 × 6 cm to 15 × 7 cm. The free fibular vascularized osteoseptocutaneous flap was used to graft and reconstruct combined bone and soft tissue defects. The radical wound débridement, soft tissue and bone revision, fracture stabilization, and early soft tissue coverage were achieved by this technique in a one-stage procedure. The average duration from injury to one-stage reconstruction was 15.8 hours (range, 5.3 hours to 6.5 days). Radiographic and functional evaluation of the lower extremity. All free fibular osteoseptocutaneous flaps survived completely. The average time to overall union for the entire group was 32 weeks after surgery (range, 26-41 weeks). None of the patients in this series had a nonunion. Acceptable radiographic alignment, defined as 5° of angulation in any plane, was obtained in 22 patients (78.6%). Malunion affected six (21.4%) fractures. According to the lower extremity functional assessment, excellent and good results were achieved for 82.1% (23 of 28), fair results were seen in 14.3

  16. Maxillary anterior segmental distraction osteogenesis with 2 different types of distractors.

    Science.gov (United States)

    Choi, Hye-Young; Hwang, Chung-Ju; Kim, Hee-Jin; Yu, Hyung-Seog; Cha, Jung-Yul

    2012-05-01

    Maxillary anterior segmental distraction osteogenesis (DO) has been the alternative treatment option for patients with midfacial retrusion. To investigate a potentially more effective maxillary anterior segmental DO, a newly designed intraoral alveolar distractor was applied. The objectives of this study were to investigate the skeletal and dental effects of maxillary anterior segmental DO and the relapse pattern. The study was carried out for 8 patients with unilateral cleft lip and palate (mean age, 16 years 7 months). Four patients were treated with an intraoral appliance (IA), and the remaining with a rigid external distractor (RED). Dental and skeletal measurements were obtained for both groups. These measurements were compared for different time points including pre-DO (T1), post-DO (T2), postconsolidation (T3), and 1-year follow-up (T4). Horizontal change of A point was significantly larger after distraction period (T2) in the RED group (mean, 11.0 mm; median, 10.1 mm) than in the IA group (mean, 6.6 mm; median, 7.4 mm) (P distraction, showing a significant difference between groups (P Maxillary anterior segmental DO is effective for the treatment of patients with cleft lip and palate. The alveolar space is regained, and the facial profile is improved without velopharyngeal problems. Superior results are obtained using the RED appliance for maxillary anterior segmental DO relative to the use of the intraoral distractor appliance.

  17. Treatment of complex internal carotid artery aneurysms using radial artery grafts. Surgical technique, perioperative complications, and results in 17 patients

    International Nuclear Information System (INIS)

    Murai, Yasuo; Teramoto, Akira; Mizunari, Takayuki; Kobayashi, Shiro; Kamiyama, Hiroyasu

    2007-01-01

    Complex giant or large internal carotid artery aneurysms present a surgical challenge because limitations and difficulty are encountered with either clipping or endovascular treatment. Our review of previous reports suggests that no current vascular assessment can accurately predict the occurrence of ischemic complications after internal carotid artery ligation. The present study concerns surgical technique, complications, and clinical outcome of radial artery grafting followed by parent artery trapping or proximal occlusion for management of these difficult lesions. Between September 1997 and October 2005, we performed radial artery grafting followed immediately by parent artery occlusion in 17 patients with giant or large complex intracranial carotid aneurysms (3 men, 14 women; mean follow-up duration, 62 months). All patients underwent postoperative digital subtraction angiography to assess graft patency and aneurysm obliteration. All 17 aneurysms were excluded from the cerebral circulation, with all radial artery grafts patent. Among 4 patients with cranial nerve disturbances, dysfunction was temporary in 5; in the others, oculomotor nerve paresis persisted. No perioperative cerebral infarction occurred. Sensory aphasia reflecting cerebral contusions caused by temporal lobe retraction resolved within 2 months, as did hemiparesis from a postoperative epidural hematoma. With appropriate attention to surgical technique, radial artery grafting followed by acute parent artery occlusion is a safe treatment for complex internal carotid artery aneurysms. Graft patency and aneurysm thrombosis were achieved in all patients. Cranial nerve dysfunction (III, VI) caused by altered blood flow from the internal carotid artery after occlusion was the most common complication and typically was temporary. In our experience with these difficult aneurysms, not only clipping but also reconstruction of the internal carotid artery was required, especially for wide-necked symptomatic

  18. Biocompatibility of polypropylene non-woven fabric membrane via UV-induced graft polymerization of 2-acrylamido-2-methylpropane sulfonic acid

    Energy Technology Data Exchange (ETDEWEB)

    Song Lingjie [State Key Laboratory of Polymer Physics and Chemistry, Changchun Institute of Applied Chemistry, Chinese Academy of Sciences, Changchun 130022 (China); Graduate University of Chinese Academy of Sciences, Beijing 100049 (China); Zhao Jie; Yang Huawei; Jin Jing; Li Xiaomeng [State Key Laboratory of Polymer Physics and Chemistry, Changchun Institute of Applied Chemistry, Chinese Academy of Sciences, Changchun 130022 (China); Stagnaro, Paola [Istituto per Io Studio delle Macromolecole, Consiglio Nazionale delle Ricerche, Via de Marini 6, 16149 Genova (Italy); Yin Jinghua, E-mail: yinjh@ciac.jl.cn [State Key Laboratory of Polymer Physics and Chemistry, Changchun Institute of Applied Chemistry, Chinese Academy of Sciences, Changchun 130022 (China)

    2011-10-15

    This work described the graft polymerization of a sulfonic acid terminated monomer, 2-acrylamido-2-methylpropane sulfonic acid (AMPS), onto the surface of polypropylene non-woven (NWF PP) membrane by O{sub 2} plasma pretreatment and UV-induced photografting method. The chemical structure and composition of the modified surfaces were analyzed by FTIR-ATR and XPS, respectively. The wettability was investigated by water contact angle and equilibrium water adsorption. And the biocompatibility of the modified NWF PP membranes was evaluated by protein adsorption and platelet adhesion. It was found that the graft density increased with prolonging UV irradiation time and increasing AMPS concentration; the water contact angles of the membranes decreased from 124{sup o} to 26{sup o} with the increasing grafting density of poly(AMPS) from 0 to 884.2 {mu}g cm{sup -2}, while the equilibrium water adsorption raised from 5 wt% to 75 wt%; the protein absorption was effectively suppressed with the introduction of poly(AMPS) even at the low grafting density (132.4 {mu}g cm{sup -2}); the number of platelets adhering to the modified membrane was dramatically reduced when compared with that on its virgin surface. These results indicated that surface modification of NWF PP membrane with AMPS was a facile approach to construct biocompatible surface.

  19. Engraftment of Prevascularized, Tissue Engineered Constructs in a Novel Rabbit Segmental Bone Defect Model

    Directory of Open Access Journals (Sweden)

    Alexandre Kaempfen

    2015-06-01

    Full Text Available The gold standard treatment of large segmental bone defects is autologous bone transfer, which suffers from low availability and additional morbidity. Tissue engineered bone able to engraft orthotopically and a suitable animal model for pre-clinical testing are direly needed. This study aimed to evaluate engraftment of tissue-engineered bone with different prevascularization strategies in a novel segmental defect model in the rabbit humerus. Decellularized bone matrix (Tutobone seeded with bone marrow mesenchymal stromal cells was used directly orthotopically or combined with a vessel and inserted immediately (1-step or only after six weeks of subcutaneous “incubation” (2-step. After 12 weeks, histological and radiological assessment was performed. Variable callus formation was observed. No bone formation or remodeling of the graft through TRAP positive osteoclasts could be detected. Instead, a variable amount of necrotic tissue formed. Although necrotic area correlated significantly with amount of vessels and the 2-step strategy had significantly more vessels than the 1-step strategy, no significant reduction of necrotic area was found. In conclusion, the animal model developed here represents a highly challenging situation, for which a suitable engineered bone graft with better prevascularization, better resorbability and higher osteogenicity has yet to be developed.

  20. A Tie-Over Dressing Using a Silicone Tube to Graft Deep Wounds

    Directory of Open Access Journals (Sweden)

    Cem Inan Bektas

    2013-11-01

    Full Text Available BackgroundThe most common cause of skin graft failure is the collection of blood or serous fluid underneath the graft. In our study, we describe the use of silicone tube for tie-over dressing to secure the skin graft margins with the aim of decreasing loss of the skin graft, particularly in grafting of deep wounds.MethodsBetween March 2008 and July 2011, we used this technique in 17 patients with skin defects with depths ranging from 3.5 to 8 mm (mean, 5.5 mm. First, the skin graft was sutured with 3/0 silk suture material from its corners. Then, a silicone round drain tube was sutured with 3/0 absorbable polyglactin 910 over the margins of the graft. Finally, long silk threads were tied over the bolus dressing, and the tie-over dressing was completed in the usual fashion.ResultsThe mean follow-up was 7 months (range, 2-10 months in the outpatient clinic. Graft loss on the graft margins due to hematoma or seroma was not developed. The results of adhesion between the graft and wound bed peripherally was excellent.ConclusionsIn our study, we suggest that use of a silicone tube for additional pressure on the edges of skin grafts in case of reconstruction of deep skin defects.

  1. Design of 3D scaffolds for tissue engineering testing a tough polylactide-based graft copolymer.

    Science.gov (United States)

    Dorati, R; Colonna, C; Tomasi, C; Genta, I; Bruni, G; Conti, B

    2014-01-01

    The aim of this research was to investigate a tough polymer to develop 3D scaffolds and 2D films for tissue engineering applications, in particular to repair urethral strictures or defects. The polymer tested was a graft copolymer of polylactic acid (PLA) synthesized with the rationale to improve the toughness of the related PLA homopolymer. The LMP-3055 graft copolymer (in bulk) demonstrated to have negligible cytotoxicity (bioavailability >85%, MTT test). Moreover, the LMP-3055 sterilized through gamma rays resulted to be cytocompatible and non-toxic, and it has a positive effect on cell biofunctionality, promoting the cell growth. 3D scaffolds and 2D film were prepared using different LMP-3055 polymer concentrations (7.5, 10, 12.5 and 15%, w/v), and the effect of polymer concentration on pore size, porosity and interconnectivity of the 3D scaffolds and 2D film was investigated. 3D scaffolds got better results for fulfilling structural and biofunctional requirements: porosity, pore size and interconnectivity, cell attachment and proliferation. 3D scaffolds obtained with 10 and 12.5% polymer solutions (3D-2 and 3D-3, respectively) were identified as the most suitable construct for the cell attachment and proliferation presenting pore size ranged between 100 and 400μm, high porosity (77-78%) and well interconnected pores. In vitro cell studies demonstrated that all the selected scaffolds were able to support the cell proliferation, the cell attachment and growth resulting to their dependency on the polymer concentration and structural features. The degradation test revealed that the degradation of polymer matrix (ΔMw) and water uptake of 3D scaffolds exceed those of 2D film and raw polymer (used as control reference), while the mass loss of samples (3D scaffold and 2D film) resulted to be controlled, they showed good stability and capacity to maintain the physical integrity during the incubation time. © 2013.

  2. Utilization of rice husk ash as silica source for the synthesis of mesoporous silicas and their application to CO2 adsorption through TREN/TEPA grafting

    International Nuclear Information System (INIS)

    Bhagiyalakshmi, Margandan; Yun, Lee Ji; Anuradha, Ramani; Jang, Hyun Tae

    2010-01-01

    Mesoporous MCM-41, MCM-48 and SBA-15 were synthesized using Rice husk ash (RHA) as the silica source and their defective Si-OH sites were functionalized by 3-cholropropyltrimethoxysilane (CPTMS) which was subsequently grafted with amine compounds, Tris(2-aminoethyl)amine (TREN) and Tetraethylenepentamine (TEPA). X-ray powder diffraction (XRD) and BET results of the parent mesoporous silica suggested their closeness of structural properties to those obtained from conventional silica sources. CO 2 adsorption of branched amine TREN and straight chain amine TEPA at 25, 50 and 75 deg. C was obtained by Thermogravimetric Analyser (TGA) at atmospheric pressure. TREN grafted mesoporous silica showed 7% of CO 2 adsorption while TEPA grafted mesoporous silicas showed less CO 2 adsorption, which is due to the presence of isolated amine groups in TREN. TREN grafted mesoporous silicas were also observed to be selective towards CO 2 , thermally stable and recyclable. The order of CO 2 adsorption with respect to amount of amine grafting was observed to be MCM-48/TREN > MCM-41/TREN > SBA-15/TREN.

  3. Comparison of FLIXENE™ and standard PTFE arteriovenous graft for early haemodialysis.

    Science.gov (United States)

    Chiang, Nathaniel; Hulme, Katherine Ria; Haggart, Paul Charles; Vasudevan, Thodur

    2014-01-01

    The purpose is to compare the outcomes of FLIXENE™ arteriovenous graft (AVG) to standard polytetrafluoroethylene (PTFE) AVG for early haemodialysis. This is a prospective observational study of all AVGs placed over a 40-month period between 2008 and 2011 at our vascular unit. Primary outcome was to examine early cannulation rates for FLIXENE™. Secondary outcomes included patency rates, usability of grafts, complications in particular infections, interventions and death in comparison to standard PTFE grafts. Forty-five FLIXENE™ and 19 standard PTFE AVGs were placed in the study period; 89% of FLIXENE™ grafts were used for dialysis, with 78% cannulated within 3 days. At 18 months, primary patency (FLIXENE™ 34% vs standard PTFE 24%), primary assisted patency (35% vs 36%) and secondary patency rate (51% vs 48%) were not statistically different; 20.2% of FLIXENE™ grafts were infected at 18 months requiring explantation compared with 40.3% of standard PTFE grafts (p=0.14). FLIXENE™ can be cannulated for dialysis within 3 days. It has similar patency and complication rates as other prosthetic grafts in the market. In patients who have no access and require urgent dialysis, FLIXENE™ is a viable option.

  4. Percutaneous Stent-Graft Repair of a Mycotic Pulmonary Artery Pseudoaneurysm

    International Nuclear Information System (INIS)

    Chou Meichun; Liang Hueilung; Pan Huayban; Yang Chienfang

    2006-01-01

    Ruptured mycotic pulmonary pseudoaneurysm is a lethal complication. Emergent surgical repair is usually recommended, but still associated with a high mortality rate. We present a patient in whom mycotic pulmonary pseudoaneurysm was a complication after surgical lobectomy 2 weeks earlier. This patient had suffered from repeated massive hemoptysis. After emergent surgical repair of the ruptured pulmonary artery stump, another episode of massive hemorrhage occurred. The pulmonary arteriogram revealed a segmental stenosis and a large, wide-necked, lobulated pseudoaneurysm at the left proximal pulmonary artery. We deployed a balloon-expandable stent-graft (48 mm in length mounted on a 12 mm x 40 mm angioplasty balloon) across the stenotic segment and the neck of the pulmonary pseudoaneurysm. Hemostasis was achieved immediately and, under a 4-week antibiotic treatment, patient was transferred to a local hospital for medical care. This case report demonstrates the benefit of minimally invasive endovascular therapy in a critically ill patient. A literature review of the etiology and management of mycotic pulmonary pseudoaneurysm is included

  5. Mild anastomotic stenosis in patient-specific CABG model may enhance graft patency: a new hypothesis.

    Directory of Open Access Journals (Sweden)

    Yunlong Huo

    Full Text Available It is well known that flow patterns at the anastomosis of coronary artery bypass graft (CABG are complex and may affect the long-term patency. Various attempts at optimal designs of anastomosis have not improved long-term patency. Here, we hypothesize that mild anastomotic stenosis (area stenosis of about 40-60% may be adaptive to enhance the hemodynamic conditions, which may contribute to slower progression of atherosclerosis. We further hypothesize that proximal/distal sites to the stenosis have converse changes that may be a risk factor for the diffuse expansion of atherosclerosis from the site of stenosis. Twelve (12 patient-specific models with various stenotic degrees were extracted from computed tomography images using a validated segmentation software package. A 3-D finite element model was used to compute flow patterns including wall shear stress (WSS and its spatial and temporal gradients (WSS gradient, WSSG, and oscillatory shear index, OSI. The flow simulations showed that mild anastomotic stenosis significantly increased WSS (>15 dynes · cm(-2 and decreased OSI (<0.02 to result in a more uniform distribution of hemodynamic parameters inside anastomosis albeit proximal/distal sites to the stenosis have a decrease of WSS (<4 dynes · cm(-2. These findings have significant implications for graft adaptation and long-term patency.

  6. Mild anastomotic stenosis in patient-specific CABG model may enhance graft patency: a new hypothesis.

    Science.gov (United States)

    Huo, Yunlong; Luo, Tong; Guccione, Julius M; Teague, Shawn D; Tan, Wenchang; Navia, José A; Kassab, Ghassan S

    2013-01-01

    It is well known that flow patterns at the anastomosis of coronary artery bypass graft (CABG) are complex and may affect the long-term patency. Various attempts at optimal designs of anastomosis have not improved long-term patency. Here, we hypothesize that mild anastomotic stenosis (area stenosis of about 40-60%) may be adaptive to enhance the hemodynamic conditions, which may contribute to slower progression of atherosclerosis. We further hypothesize that proximal/distal sites to the stenosis have converse changes that may be a risk factor for the diffuse expansion of atherosclerosis from the site of stenosis. Twelve (12) patient-specific models with various stenotic degrees were extracted from computed tomography images using a validated segmentation software package. A 3-D finite element model was used to compute flow patterns including wall shear stress (WSS) and its spatial and temporal gradients (WSS gradient, WSSG, and oscillatory shear index, OSI). The flow simulations showed that mild anastomotic stenosis significantly increased WSS (>15 dynes · cm(-2)) and decreased OSI (<0.02) to result in a more uniform distribution of hemodynamic parameters inside anastomosis albeit proximal/distal sites to the stenosis have a decrease of WSS (<4 dynes · cm(-2)). These findings have significant implications for graft adaptation and long-term patency.

  7. Segmentation process significantly influences the accuracy of 3D surface models derived from cone beam computed tomography

    International Nuclear Information System (INIS)

    Fourie, Zacharias; Damstra, Janalt; Schepers, Rutger H.; Gerrits, Peter O.; Ren Yijin

    2012-01-01

    Aims: To assess the accuracy of surface models derived from 3D cone beam computed tomography (CBCT) with two different segmentation protocols. Materials and methods: Seven fresh-frozen cadaver heads were used. There was no conflict of interests in this study. CBCT scans were made of the heads and 3D surface models were created of the mandible using two different segmentation protocols. The one series of 3D models was segmented by a commercial software company, while the other series was done by an experienced 3D clinician. The heads were then macerated following a standard process. A high resolution laser surface scanner was used to make a 3D model of the macerated mandibles, which acted as the reference 3D model or “gold standard”. The 3D models generated from the two rendering protocols were compared with the “gold standard” using a point-based rigid registration algorithm to superimpose the three 3D models. The linear difference at 25 anatomic and cephalometric landmarks between the laser surface scan and the 3D models generate from the two rendering protocols was measured repeatedly in two sessions with one week interval. Results: The agreement between the repeated measurement was excellent (ICC = 0.923–1.000). The mean deviation from the gold standard by the 3D models generated from the CS group was 0.330 mm ± 0.427, while the mean deviation from the Clinician's rendering was 0.763 mm ± 0.392. The surface models segmented by both CS and DS protocols tend to be larger than those of the reference models. In the DS group, the biggest mean differences with the LSS models were found at the points ConLatR (CI: 0.83–1.23), ConMedR (CI: −3.16 to 2.25), CoLatL (CI: −0.68 to 2.23), Spine (CI: 1.19–2.28), ConAntL (CI: 0.84–1.69), ConSupR (CI: −1.12 to 1.47) and RetMolR (CI: 0.84–1.80). Conclusion: The Commercially segmented models resembled the reality more closely than the Doctor's segmented models. If 3D models are needed for surgical drilling

  8. Metal Adsorbent Prepared from Poly(Methyl Acrylate)-Grafted Cassava Starch via Gamma Irradiation

    Energy Technology Data Exchange (ETDEWEB)

    Suwanmala, P; Hemvichian, K; Srinuttrakul, W [Nuclear Research and Development Group, Thailand Institute of Nuclear Technology, Bangkok (Thailand)

    2012-09-15

    Metal adsorbent containing hydroxamic acid groups was successfully synthesized by radiation-induced graft copolymerization of methyl acrylate (MA) onto cassava starch. The optimum conditions for grafting were studied in terms of % degree of grafting (Dg). Conversion of the ester groups present in poly(methyl acrylate)-grafted-cassava starch copolymer into hydroxamic acid was carried out by treatment with hydroxylamine (HA) in the presence of alkaline solution. The maximum percentage conversion of the ester groups of the grafted copolymer, %Dg = 191 (7.63 mmol/g of MA), into the hydroxamic groups was 70% (5.35 mmol/g of MA) at the optimum conditions: in a mixture solution of 20% HA (w/v) and methanol solution (methanol:H{sub 2}O = 5:1) 300 mL, pH 13, reaction time 2 h, and 20 g of grafted copolymer. The adsorbent was characterized by FTIR, TGA, and DSC. The presence of electron donating groups in adsorbent containing hydroxamic acid groups gives the ability to form polycomplexes with metal ions. The ability of the adsorbent to adsorb various metals was investigated in order to evaluate the possibility of its use in metal adsorption. The adsorbent exhibited a remarkable % adsorption for Cd{sup 2+}, Al{sup 3+}, UO{sub 2} {sup 2+}, V{sup 5+} and Pb{sup 2+} at pH 3, 4, 5, 4, and 3, respectively. The adsorbent of 191%Dg had total adsorption capacities of 2.6, 1.46, 1.36, 1.15, and 1.6 mmol/g adsorbent for Cd{sup 2+}, Al{sup 3+}, UO{sub 2} {sup 2+}, V{sup 5+} and Pb{sup 2+}, respectively, in the batch mode adsorption. (author)

  9. Diazonium salt derivatives of osmium bipyridine complexes: Electrochemical grafting and characterisation of modified surfaces

    Energy Technology Data Exchange (ETDEWEB)

    Garrett, David J. [MacDiarmid Institute for Advanced Materials and Nanotechnology, Department of Chemistry, University of Canterbury, Private Bag 4800, Christchurch (New Zealand); Jenkins, Peter [School of Chemistry, National University of Ireland, Galway (Ireland); Polson, Matthew I.J. [Department of Chemistry, University of Canterbury, Private Bag 4800, Christchurch (New Zealand); Leech, Donal [School of Chemistry, National University of Ireland, Galway (Ireland); Baronian, Keith H.R. [School of Biological Sciences, University of Canterbury, Private Bag 4800, Christchurch (New Zealand); Downard, Alison J., E-mail: alison.downard@canterbury.ac.n [MacDiarmid Institute for Advanced Materials and Nanotechnology, Department of Chemistry, University of Canterbury, Private Bag 4800, Christchurch (New Zealand)

    2011-02-01

    Osmium bipyridine complexes were directly grafted to carbon electrodes through electroreduction of the diazonium salts [Os(bpy-ph-N{sub 2}{sup +}){sub 3}](PF{sub 6}){sub 5} (1) and [Os(bpy-ph-N{sub 2}{sup +}){sub 2}Cl{sub 2}](PF{sub 6}){sub 2} (2). Growth of the films was not self-limiting as is usually found for grafting from diazonium salts. It appears that electron hopping through the bipyridine ligands of the immobilised complexes enables film growth to continue at a constant rate during grafting by potential cycling. The surface concentrations of deposited films were measured electrochemically and the film thicknesses were measured by depth-profiling using the atomic force microscope. Films up to 42 nm thick were prepared with no evidence for slowing of film growth. The grafted films exhibited high stability when repetitively cycled through the Os{sup 2+/3+} couple and electron transfer rate constants of 11.4 s{sup -1} and 35.4 s{sup -1} were measured in ACN and PBS, respectively, for the Os{sup 2+/3+} couple of the film grafted from 1.

  10. Reactivity study of silicon electrode modified by grafting using electrochemical reduction of diazonium salts

    International Nuclear Information System (INIS)

    Kaiber, A.; Cherkkaoui, M.; Chazalviel, J.N.

    2015-01-01

    The use of the hydrogenated surface of silicon is hampered by its chemical instability by surface oxidation. The researchers have attempted to modify this surface by direct grafting through the establishment of covalent silicon-carbon bonds from the reaction of chemical species on the surface. Different grafting methods can be implemented for the preparation of grafted surfaces. The choice of an electrochemical reaction allows fast grafting from the hydrogenated surface. We studied the formation of a phenyl layer by electrochemical reduction of aryl diazonium salts (BF4-,+N2-ph-OCH3) on a p-Si-H (111) electrode in an aqueous medium (0.05M H/sub 2/SO/sub 4/ + 0.05M HF). The grafting of an organic layer by reduction is confirmed by the observation of a cyclic voltammetry peak around -0.3V/SCE. In-situ infrared spectroscopy (IR) analysis allows to identify the chemical functions present on the grafted surface, allowing a direct monitoring of the grafting reaction. (author)

  11. Deliberate and Crisis Action Planning and Execution Segments Increment 2A (DCAPES Inc 2A)

    Science.gov (United States)

    2016-03-01

    2016 Major Automated Information System Annual Report Deliberate and Crisis Action Planning and Execution Segments Increment 2A (DCAPES Inc 2A...Program Name Deliberate and Crisis Action Planning and Execution Segments Increment 2A (DCAPES Inc 2A) DoD Component Air Force Responsible Office Program...APB) dated March 9, 2015 DCAPES Inc 2A 2016 MAR UNCLASSIFIED 4 Program Description Deliberate and Crisis Action Planning and Execution Segments

  12. Deliberate and Crisis Action Planning and Execution Segments Increment 2B (DCAPES Inc 2B)

    Science.gov (United States)

    2016-03-01

    2016 Major Automated Information System Annual Report Deliberate and Crisis Action Planning and Execution Segments Increment 2B (DCAPES Inc 2B...Information Program Name Deliberate and Crisis Action Planning and Execution Segments Increment 2B (DCAPES Inc 2B) DoD Component Air Force Responsible Office...been established. DCAPES Inc 2B 2016 MAR UNCLASSIFIED 4 Program Description Deliberate and Crisis Action Planning and Execution Segments (DCAPES) is

  13. [Surface grafting modification and stabilization of Kevlar fiber].

    Science.gov (United States)

    Zheng, Yu-ying; Fu, Ming-lian; Wang, Can-yao; Wang, Liang-en

    2005-11-01

    Chemical disposal was used to bring the activity group onto the surface of Kevlar fiber for the purpose of surface grafting modification. The interfacial constitution of the grafting of toluene-2,4-diisocyanate (TDI) onto Kevlar fiber was determined by Fourier transform infrared spectroscopy. In the mean time, hexyl-lactam stabilization and poly-glycol (400, PEG) stabilization on the grafted product were also studied. The effects of different nTDI:nPEG ratios on the production's interfacial constitution was analysed. It is concluded that the stabilization took place on the surface. The intensity of the bands relented at about 3300 cm(-1) and was reinforced at about 1700-1720 cm(-1) when the ratio of nTDI:nPEG = 1:3, but when the ratio is 1:1 and 1:2, the bands at about 3 300 and 1700-1720 cm(-1) are almost the same.

  14. Soft tissue segmentation and 3D display from computerized tomography and magnetic resonance imaging

    International Nuclear Information System (INIS)

    Fan, R.T.; Trivedi, S.S.; Fellingham, L.L.; Gamboa-Aldeco, A.; Hedgcock, M.W.

    1987-01-01

    Volume calculation and 3D display of human anatomy facilitate a physician's diagnosis, treatment, and evaluation. Accurate segmentation of soft tissue structures is a prerequisite for such volume calculations and 3D displays, but segmentation by hand-outlining structures is often tedious and time-consuming. In this paper, methods based on analysis of statistics of image gray level are applied to segmentation of soft tissue in medical images, with the goal of making segmentation automatic or semi-automatic. The resulting segmented images, volume calculations, and 3D displays are analyzed and compared with results based on physician-drawn outlines as well as actual volume measurements

  15. Interactive 3D segmentation using connected orthogonal contours

    NARCIS (Netherlands)

    de Bruin, P. W.; Dercksen, V. J.; Post, F. H.; Vossepoel, A. M.; Streekstra, G. J.; Vos, F. M.

    2005-01-01

    This paper describes a new method for interactive segmentation that is based on cross-sectional design and 3D modelling. The method represents a 3D model by a set of connected contours that are planar and orthogonal. Planar contours overlayed on image data are easily manipulated and linked contours

  16. Automated 3D closed surface segmentation: application to vertebral body segmentation in CT images.

    Science.gov (United States)

    Liu, Shuang; Xie, Yiting; Reeves, Anthony P

    2016-05-01

    A fully automated segmentation algorithm, progressive surface resolution (PSR), is presented in this paper to determine the closed surface of approximately convex blob-like structures that are common in biomedical imaging. The PSR algorithm was applied to the cortical surface segmentation of 460 vertebral bodies on 46 low-dose chest CT images, which can be potentially used for automated bone mineral density measurement and compression fracture detection. The target surface is realized by a closed triangular mesh, which thereby guarantees the enclosure. The surface vertices of the triangular mesh representation are constrained along radial trajectories that are uniformly distributed in 3D angle space. The segmentation is accomplished by determining for each radial trajectory the location of its intersection with the target surface. The surface is first initialized based on an input high confidence boundary image and then resolved progressively based on a dynamic attraction map in an order of decreasing degree of evidence regarding the target surface location. For the visual evaluation, the algorithm achieved acceptable segmentation for 99.35 % vertebral bodies. Quantitative evaluation was performed on 46 vertebral bodies and achieved overall mean Dice coefficient of 0.939 (with max [Formula: see text] 0.957, min [Formula: see text] 0.906 and standard deviation [Formula: see text] 0.011) using manual annotations as the ground truth. Both visual and quantitative evaluations demonstrate encouraging performance of the PSR algorithm. This novel surface resolution strategy provides uniform angular resolution for the segmented surface with computation complexity and runtime that are linearly constrained by the total number of vertices of the triangular mesh representation.

  17. Ionic membranes obtained by radiation - induced graft copolymerization, II-characterization and waste treatment. Vol. 3

    International Nuclear Information System (INIS)

    Ali, A.M.I.; Nowier, H.G.; Aly, H.F.; Abd El-Rehim, H.A.; Hegazy, E.A.

    1996-01-01

    Ionic membranes were prepared by radiation-induced grafting of acrylic acid onto low density polyethylene films. To elucidate the possibility of practical use, a study was made for the characterization of the grafted and chemically treated mechanisms. The selectivity of such prepared membranes towards the chelation or absorption of different alkali metals was investigated, to find that the higher affinity was observed for K + , Na + and Li + ions compared to other alkali metals used. The metal uptake percent was determined using different techniques; flame photometer, and X-ray fluorescence (XRF). The uptake of metal from its feed solution by the the grafted membrane increased as the degree of grating increased, i.e. it is directly proportional to the functional carboxylic acid groups in the graft copolymer. As a consequence, the electrical conductivity of metal feed solution decreased during such process of metal chelation by membrane. The higher the grafting degree of membrane, the lower the electrical conductivity of metal feed solutions observed. the changes in thermal properties of the membranes prepared were investigated and characterized using differential scanning calorimetry, (DSC), and thermal gravimetric analysis (TGA). The thermal stability of these membranes increased with degree of grafting due to the formation of cross linked network structure via hydrogen bonding. furthermore, such stability is enhanced for the alkali-treated membranes even at high elevated temperatures. The membranes prepared showed a great promise for possible use in some practical applications such as metal waste treatment. 3 figs., 5 tabs

  18. Graft union formation in Douglas-fir.

    Science.gov (United States)

    D.L. Copes

    1969-01-01

    Greenhouse-grown Douglas-fir (Pseudotsuga menziesii [Mirb.] Franco) graft unions were examined between 2 and 84 days after grafting. Room temperature was maintained at 60-70 F throughout the growing season. In most respects grafts of Douglas-fir followed development patterns previously reported for spruce and pine grafts, but specific differences...

  19. Design of a Sapling Branch Grafting Robot

    Directory of Open Access Journals (Sweden)

    Qun Sun

    2014-01-01

    Full Text Available The automatic sapling grafting methods and grafting robot technologies are not comprehensively studied despite the fact that they are urgently required in practice. For this reason, a sapling grafting robot is developed to implement automatic grafting for saplings. The developed grafting robot includes clipping mechanism, moving mechanism, cutting mechanism, binding mechanism, and Arduino MCU based control system, which is capable of clipping, moving, positioning, cutting, grafting, and binding saplings. Experiments show that the stock cutting efficiency is 98.4%, the scion cutting efficiency is 98.9%, the grafting efficiency is 87.3%, and the binding efficiency is 68.9%.

  20. Reconstruction of the abdominal vagus nerve using sural nerve grafts in canine models.

    Science.gov (United States)

    Liu, Jingbo; Wang, Jun; Luo, Fen; Wang, Zhiming; Wang, Yin

    2013-01-01

    Recently, vagus nerve preservation or reconstruction of vagus has received increasing attention. The present study aimed to investigate the feasibility of reconstructing the severed vagal trunk using an autologous sural nerve graft. Ten adult Beagle dogs were randomly assigned to two groups of five, the nerve grafting group (TG) and the vagal resection group (VG). The gastric secretion and emptying functions in both groups were assessed using Hollander insulin and acetaminophen tests before surgery and three months after surgery. All dogs underwent laparotomy under general anesthesia. In TG group, latency and conduction velocity of the action potential in a vagal trunk were measured, and then nerves of 4 cm long were cut from the abdominal anterior and posterior vagal trunks. Two segments of autologous sural nerve were collected for performing end-to-end anastomoses with the cut ends of vagal trunk (8-0 nylon suture, 3 sutures for each anastomosis). Dogs in VG group only underwent partial resections of the anterior and posterior vagal trunks. Laparotomy was performed in dogs of TG group, and latency and conduction velocity of the action potential in their vagal trunks were measured. The grafted nerve segment was removed, and stained with anti-neurofilament protein and toluidine blue. Latency of the action potential in the vagal trunk was longer after surgery than before surgery in TG group, while the conduction velocity was lower after surgery. The gastric secretion and emptying functions were weaker after surgery in dogs of both groups, but in TG group they were significantly better than in VG group. Anti-neurofilament protein staining and toluidine blue staining showed there were nerve fibers crossing the anastomosis of the vagus and sural nerves in dogs of TG group. Reconstruction of the vagus nerve using the sural nerve is technically feasible.

  1. Reconstruction of the abdominal vagus nerve using sural nerve grafts in canine models.

    Directory of Open Access Journals (Sweden)

    Jingbo Liu

    Full Text Available BACKGROUND: Recently, vagus nerve preservation or reconstruction of vagus has received increasing attention. The present study aimed to investigate the feasibility of reconstructing the severed vagal trunk using an autologous sural nerve graft. METHODS: Ten adult Beagle dogs were randomly assigned to two groups of five, the nerve grafting group (TG and the vagal resection group (VG. The gastric secretion and emptying functions in both groups were assessed using Hollander insulin and acetaminophen tests before surgery and three months after surgery. All dogs underwent laparotomy under general anesthesia. In TG group, latency and conduction velocity of the action potential in a vagal trunk were measured, and then nerves of 4 cm long were cut from the abdominal anterior and posterior vagal trunks. Two segments of autologous sural nerve were collected for performing end-to-end anastomoses with the cut ends of vagal trunk (8-0 nylon suture, 3 sutures for each anastomosis. Dogs in VG group only underwent partial resections of the anterior and posterior vagal trunks. Laparotomy was performed in dogs of TG group, and latency and conduction velocity of the action potential in their vagal trunks were measured. The grafted nerve segment was removed, and stained with anti-neurofilament protein and toluidine blue. RESULTS: Latency of the action potential in the vagal trunk was longer after surgery than before surgery in TG group, while the conduction velocity was lower after surgery. The gastric secretion and emptying functions were weaker after surgery in dogs of both groups, but in TG group they were significantly better than in VG group. Anti-neurofilament protein staining and toluidine blue staining showed there were nerve fibers crossing the anastomosis of the vagus and sural nerves in dogs of TG group. CONCLUSION: Reconstruction of the vagus nerve using the sural nerve is technically feasible.

  2. Skin graft

    Science.gov (United States)

    Skin transplant; Skin autografting; FTSG; STSG; Split thickness skin graft; Full thickness skin graft ... donor site. Most people who are having a skin graft have a split-thickness skin graft. This takes ...

  3. Sloped Terrain Segmentation for Autonomous Drive Using Sparse 3D Point Cloud

    Directory of Open Access Journals (Sweden)

    Seoungjae Cho

    2014-01-01

    Full Text Available A ubiquitous environment for road travel that uses wireless networks requires the minimization of data exchange between vehicles. An algorithm that can segment the ground in real time is necessary to obtain location data between vehicles simultaneously executing autonomous drive. This paper proposes a framework for segmenting the ground in real time using a sparse three-dimensional (3D point cloud acquired from undulating terrain. A sparse 3D point cloud can be acquired by scanning the geography using light detection and ranging (LiDAR sensors. For efficient ground segmentation, 3D point clouds are quantized in units of volume pixels (voxels and overlapping data is eliminated. We reduce nonoverlapping voxels to two dimensions by implementing a lowermost heightmap. The ground area is determined on the basis of the number of voxels in each voxel group. We execute ground segmentation in real time by proposing an approach to minimize the comparison between neighboring voxels. Furthermore, we experimentally verify that ground segmentation can be executed at about 19.31 ms per frame.

  4. Effect of Ticagrelor Plus Aspirin, Ticagrelor Alone, or Aspirin Alone on Saphenous Vein Graft Patency 1 Year After Coronary Artery Bypass Grafting: A Randomized Clinical Trial.

    Science.gov (United States)

    Zhao, Qiang; Zhu, Yunpeng; Xu, Zhiyun; Cheng, Zhaoyun; Mei, Ju; Chen, Xin; Wang, Xiaowei

    2018-04-24

    The effect of ticagrelor with or without aspirin on saphenous vein graft patency in patients undergoing coronary artery bypass grafting (CABG) is unknown. To compare the effect of ticagrelor + aspirin or ticagrelor alone vs aspirin alone on saphenous vein graft patency 1 year after CABG. Randomized, multicenter, open-label, clinical trial among 6 tertiary hospitals in China. Eligible patients were aged 18 to 80 years with indications for elective CABG. Patients requiring urgent revascularization, concomitant cardiac surgery, dual antiplatelet or vitamin K antagonist therapy post-CABG, and who were at risk of serious bleeding were excluded. From July 2014 until November 2015, 1256 patients were identified and 500 were enrolled. Follow-up was completed in January 2017. Patients were randomized (1:1:1) to start ticagrelor (90 mg twice daily) + aspirin (100 mg once daily) (n = 168), ticagrelor (90 mg twice daily) (n = 166), or aspirin (100 mg once daily) (n = 166) within 24 hours post-CABG. Neither patients nor treating physicians were blinded to allocation. Primary outcome was saphenous vein graft patency 1 year after CABG (FitzGibbon grade A) adjudicated independently by a committee blinded to allocation. Saphenous vein graft patency was assessed by multislice computed tomographic angiography or coronary angiography. Among 500 randomized patients (mean age, 63.6 years; women, 91 [18.2%]), 461 (92.2%) completed the trial. Saphenous vein graft patency rates 1 year post-CABG were 88.7% (432 of 487 vein grafts) with ticagrelor + aspirin; 82.8% (404 of 488 vein grafts) with ticagrelor alone; and 76.5% (371 of 485 vein grafts) with aspirin alone. The difference between ticagrelor + aspirin vs aspirin alone was statistically significant (12.2% [95% CI, 5.2% to 19.2%]; P aspirin alone was not statistically significant (6.3% [95% CI, -1.1% to 13.7%]; P = .10). Five major bleeding episodes occurred during 1 year of follow-up (3 with

  5. Endo-luminal grafting for treatment of abdominal aortic aneurysms

    International Nuclear Information System (INIS)

    Fu Weiguo; Wang Yuqi; Chen Fuzhen; Ye Jianrong; Wang Jianhua; Yan Zhiping; Cheng Jiemin

    2000-01-01

    Objective: To evaluate the preliminary clinical results of endovascular procedures for abdominal aortic aneurysms (AAA) in a prospective study. Methods: Six patients (average age 70 years, range 56 to 78) with infrarenal AAA were enrolled in Shanghai Zhongshan hospital from February 1998 to February 1999. Computed tomography and angiography were done in every patient for measurement of the length, diameter, and angulation of the proximal and distal AAA necks, aneurysm sac, and common and external iliac arteries. The average diameter of the aneurysm was 6.3 cm (range 4.6 cm to 8.0 cm). The mean proximal neck diameter was 2.0 cm (range 1.8 cm to 2.2 cm) and proximal neck length was 3.0 cm (range 2.5 cm to 3.5 cm). All patients were treated with the endo-luminal grafting for exclusion of AAA. Results: Two tubular and 4 bifurcated endo-grafts were used. All endo-graft procedures were completed successfully. One patient died of renal failure 72 hours after the procedure because of the prolonged operative time and excessive contrast medium. Aortography after the procedure showed the AAA were excluded by endo-graft and no endo-leak in the proximal or distal connections was detected. The patients could take meal and were ambulatory on the first and second postoperative day, respectively. Clinical success (aneurysm exclusion with no death or endo-leak) at 30 days was 83.3%. In the 24 months follow-up in 5 cases, no migration, endo-leak, and increasing aneurysm size were detected with spiral CT or color Duplex ultrasound. Conclusion: Based on initial results and a short term mean follow-up period of 24 months, the endovascular treatment of AAA with stent-graft system is feasible and safe. Further study will be required to observe the long term result in the exclusion of AAA

  6. Lung segment geometry study: simulation of largest possible tumours that fit into bronchopulmonary segments.

    Science.gov (United States)

    Welter, S; Stöcker, C; Dicken, V; Kühl, H; Krass, S; Stamatis, G

    2012-03-01

    Segmental resection in stage I non-small cell lung cancer (NSCLC) has been well described and is considered to have similar survival rates as lobectomy but with increased rates of local tumour recurrence due to inadequate parenchymal margins. In consequence, today segmentectomy is only performed when the tumour is smaller than 2 cm. Three-dimensional reconstructions from 11 thin-slice CT scans of bronchopulmonary segments were generated, and virtual spherical tumours were placed over the segments, respecting all segmental borders. As a next step, virtual parenchymal safety margins of 2 cm and 3 cm were subtracted and the size of the remaining tumour calculated. The maximum tumour diameters with a 30-mm parenchymal safety margin ranged from 26.1 mm in right-sided segments 7 + 8 to 59.8 mm in the left apical segments 1-3. Using a three-dimensional reconstruction of lung CT scans, we demonstrated that segmentectomy or resection of segmental groups should be feasible with adequate margins, even for larger tumours in selected cases. Thieme Medical Publishers 333 Seventh Avenue, New York, NY 10001, USA.

  7. Evolution of skin grafting for treatment of burns: Reverdin pinch grafting to Tanner mesh grafting and beyond.

    Science.gov (United States)

    Singh, Mansher; Nuutila, Kristo; Collins, K C; Huang, Anne

    2017-09-01

    Skin grafting is the current standard care in the treatment of full thickness burns. It was first described around 1500 BC but the vast majority of advancements have been achieved over the past 200 years. An extensive literature review was conducted on Pubmed, Medline and Google Scholar researching the evolution of skin grafting techniques. The authors concentrated on the major landmarks of skin grafting and also provide an overview of ongoing research efforts in this field. The major innovations of skin grafting include Reverdin pinch grafting, Ollier grafting, Thiersch grafting, Wolfe grafting, Padgett dermatome and modifications, Meek-wall microdermatome and Tanner mesh grafting. A brief description of the usage, advantages and limitations of each technique is included in the manuscript. Skin grafting technique have evolved significantly over past 200 years from Reverdin pinch grafting to modern day meshed skin grafts using powered dermatome. Increasing the expansion ratio and improving the cosmetic and functional outcome are the main focus of ongoing skin grafting research and emerging techniques (such as Integra ® , Recell ® , Xpansion ® ) are showing promise. Copyright © 2017 Elsevier Ltd and ISBI. All rights reserved.

  8. Bladder Mucosal Graft Vaginoplasty: A Case Report.

    Science.gov (United States)

    Chiaramonte, Cinzia; Vestri, Elettra; Tripi, Flavia; Giannone, Antonino Giulio; Cimador, Marcello; Cataliotti, Ferdinando

    2018-06-18

    Female vaginoplasty reconstruction, by choice, is usually performed with adjacent tissue. However in some clinical conditions such as high urogenital confluence sinus, cloacal malformation with extreme vaginal hypoplasia, local tissue may not be available. When vaginal replacement is performed in pediatric patients intestinal segments is preferred to non-operative procedures that require continuative dilations. However mucus production, malignant transformation risk and diversion colitis are important side effects. We present a nouvel technique for vaginoplasty in a female child presenting with an isolated urogenital sinus malformation without virilization. The patient at 20 months underwent vaginoplasty using tubularized bladder mucosal graft. Surgical procedure was devoid of complications. Pubertal development occurred at age of 15. She underwent regular follow up until 18 years of age. At this age we performed clinical evaluation: absence of vaginal introitus stenosis and good cosmetic results were observed. Then she underwent vaginoscopy with multiple biopsies. Pathology examination of the bladder mucosal graft evidenced a normal structure of the mucosa, with a stratified squamous epithelium. Different techniques are taken into account for vaginal reconstruction according to the severity and to the type of malformation. We describe the use of bladder mucosal graft with favorable results after long term follow-up. Copyright © 2018. Published by Elsevier Inc.

  9. Polyhydroxybutyrate/valerate/polycaprolactone small-diameter vascular graft: Experimental study of integration into organism

    Energy Technology Data Exchange (ETDEWEB)

    Antonova, L. V., E-mail: antonova.la@mail.ru; Burago, A. Yu.; Matveeva, V. G.; Velikanova, E. A.; Mukhamadiyarov, R. A.; Glushkova, T. V.; Kudryavtseva, Y. A.; Barbarash, O. L.; Barbarash, L. S. [Research Institute for Complex Issues of Cardiovascular Diseases, Kemerovo (Russian Federation); Mironov, A. V. [Kemerovo Cardiology Dispensary, Kemerovo (Russian Federation)

    2015-10-27

    We prepared polyhydroxybutyrate/valerate (PHBV)/polylcaprolactone (PCL) small-diameter vascular grafts using electrospinning. Surface structure was assessed by scanning electron microscopy whilst physicomechanical properties were investigated by longitudinal uniaxial tension testing. Patency of grafts implanted into the rat abdominal aorta was evaluated using a Doppler ultrasonography at 2 week, 1 month and 12 month postimplantation. In addition, we assessed local histological features, along with IL-1β, IL-2, IL-4, IL-10, TNFa, TGF-β1, and VEGF serum levels. We revealed that only 2 (25%) grafts were not thrombosed at 2 week and 1 month postimplantation. However, at 12 month postimplantation a satisfactory histological pattern was observed in 50% of all cases, and we detected a monolayer of endothelial cells on the inner graft surface in half the cases. Regarding other grafts, we revealed minor connective tissue hyperplasia in 41.7% of the grafts and an inflammatory infiltrate in the part of the arterial wall in 8.3% of the grafts. We found that the IL-1β serum level was 3.5-fold higher in the group of experimental rats at 12 month postimplantation (p < 0.01). In addition, the IL-2 and IL-4 serum levels at 12 month postimplantation were 2- and 2.8-fold higher as compared to short-term implantation (2 weeks and 1 month) and control rats (p < 0.05) whilst the IL-10 serum level at 1 and 12 month postimplantation was more than 100-fold higher in comparison with 2 week postimplantation and control rats (p < 0.001). Serum VEGF was detected only at 12 month postimplantation. All in all, we created a biocompatible PHBV/PCL small-diameter vascular graft with a high surface area to volume ratio. A long-term patency of biodegradable vascular grafts after implantation into the rat abdominal aorta and the absence of a considerable immune response confirmed a high biocompatibility of such construct and the possibility of its use as a vascular graft.

  10. Evaluation of fluency stent-grafts in transjugular intrahepatic portosystemic shunts

    International Nuclear Information System (INIS)

    Zhao Jianbo; Li Yanhao; Chen Yong; He Xiaofeng; Zeng Qingle; Mei Quelin; Lu Wei

    2009-01-01

    Objective: To evaluate the efficacy of Fluency stent-graft (Bard Corp) in transjugular intrahepatic portosystemic shunt (TIPS). Methods: The clinical data of 21 consecutive patients treated by TIPS using Fluency stent-grafts were retrospectively reviewed. All of them were recurrent variceal bleeding secondary to portal vein hypertension, 1 was bleeding secondary to primary hepatic carcinoma with port vein thrombus, and 1 was Budd-Chiari syndrome. They were followed-up after (10.1±4.6) months (2.0 to 24.0 months). Stent-grafts patancy, portal vein pressure and liver function were recorded and compared. Results: Twenty-five stent-grafts were successfully implanted in 21 patients, 23 stent grafts were 8 mm 2 were 10 mm in diameter. The covered length of the stents varied from 6 to 8 cm. The bleeding was stopped and the portal vein pressure decreased significantly from (25.4±3.5) mm Hg to (15.4±2.8) mm Hg (t= 12.495, P 0.05). Conclusion: The Fluency stent-grafts could increase the patency of the TIPS, but its efficacy on the long-term effect and hepatic encephalopathy need further investigation. (authors)

  11. 3D statistical shape models incorporating 3D random forest regression voting for robust CT liver segmentation

    Science.gov (United States)

    Norajitra, Tobias; Meinzer, Hans-Peter; Maier-Hein, Klaus H.

    2015-03-01

    During image segmentation, 3D Statistical Shape Models (SSM) usually conduct a limited search for target landmarks within one-dimensional search profiles perpendicular to the model surface. In addition, landmark appearance is modeled only locally based on linear profiles and weak learners, altogether leading to segmentation errors from landmark ambiguities and limited search coverage. We present a new method for 3D SSM segmentation based on 3D Random Forest Regression Voting. For each surface landmark, a Random Regression Forest is trained that learns a 3D spatial displacement function between the according reference landmark and a set of surrounding sample points, based on an infinite set of non-local randomized 3D Haar-like features. Landmark search is then conducted omni-directionally within 3D search spaces, where voxelwise forest predictions on landmark position contribute to a common voting map which reflects the overall position estimate. Segmentation experiments were conducted on a set of 45 CT volumes of the human liver, of which 40 images were randomly chosen for training and 5 for testing. Without parameter optimization, using a simple candidate selection and a single resolution approach, excellent results were achieved, while faster convergence and better concavity segmentation were observed, altogether underlining the potential of our approach in terms of increased robustness from distinct landmark detection and from better search coverage.

  12. 3D variational brain tumor segmentation using Dirichlet priors on a clustered feature set.

    Science.gov (United States)

    Popuri, Karteek; Cobzas, Dana; Murtha, Albert; Jägersand, Martin

    2012-07-01

    Brain tumor segmentation is a required step before any radiation treatment or surgery. When performed manually, segmentation is time consuming and prone to human errors. Therefore, there have been significant efforts to automate the process. But, automatic tumor segmentation from MRI data is a particularly challenging task. Tumors have a large diversity in shape and appearance with intensities overlapping the normal brain tissues. In addition, an expanding tumor can also deflect and deform nearby tissue. In our work, we propose an automatic brain tumor segmentation method that addresses these last two difficult problems. We use the available MRI modalities (T1, T1c, T2) and their texture characteristics to construct a multidimensional feature set. Then, we extract clusters which provide a compact representation of the essential information in these features. The main idea in this work is to incorporate these clustered features into the 3D variational segmentation framework. In contrast to previous variational approaches, we propose a segmentation method that evolves the contour in a supervised fashion. The segmentation boundary is driven by the learned region statistics in the cluster space. We incorporate prior knowledge about the normal brain tissue appearance during the estimation of these region statistics. In particular, we use a Dirichlet prior that discourages the clusters from the normal brain region to be in the tumor region. This leads to a better disambiguation of the tumor from brain tissue. We evaluated the performance of our automatic segmentation method on 15 real MRI scans of brain tumor patients, with tumors that are inhomogeneous in appearance, small in size and in proximity to the major structures in the brain. Validation with the expert segmentation labels yielded encouraging results: Jaccard (58%), Precision (81%), Recall (67%), Hausdorff distance (24 mm). Using priors on the brain/tumor appearance, our proposed automatic 3D variational

  13. Grafting 3-mercaptopropyl trimethoxysilane on multi-walled carbon nanotubes surface for improving on-line cadmium(II) preconcentration from water samples

    Energy Technology Data Exchange (ETDEWEB)

    Corazza, Marcela Zanetti; Somera, Bruna Fabrin; Segatelli, Mariana Gava [Departamento de Quimica, Universidade Estadual de Londrina, Rodovia Celso Garcia Cid, PR 445, Km 380, Campus Universitario, Londrina-PR, CEP 86051-990 (Brazil); Tarley, Cesar Ricardo Teixeira, E-mail: tarley@uel.br [Departamento de Quimica, Universidade Estadual de Londrina, Rodovia Celso Garcia Cid, PR 445, Km 380, Campus Universitario, Londrina-PR, CEP 86051-990 (Brazil); Instituto Nacional de Ciencia e Tecnologia (INCT) de Bioanalitica, Universidade Estadual de Campinas (UNICAMP), Instituto de Quimica, Departamento de Quimica Analitica, Cidade Universitaria Zeferino, Vaz, s/n, CEP 13083-970, Campinas-SP (Brazil)

    2012-12-15

    Highlights: Black-Right-Pointing-Pointer 3-Mercaptopropyl trimethoxysilane grafted on MWCNT surface was prepared. Black-Right-Pointing-Pointer The material promoted an increase on performance of MWCNT for Cd{sup 2+} adsorption. Black-Right-Pointing-Pointer The life time of adsorbent was very high. Black-Right-Pointing-Pointer An improvement of 84% on the sensitivity was achieved. - Abstract: In the present study, the performance of multi-walled carbon nanotubes (MWCNTs) grafted with 3-mercaptopropyltrimethoxysilane (3-MPTMS), used as a solid phase extractor for Cd{sup 2+} preconcentration in a flow injection system coupled to flame atomic absorption spectrometry (FAAS), was evaluated. The procedure involved the preconcentration of 20.0 mL of Cd{sup 2+} solution at pH 7.5 (0.1 mol L{sup -1} buffer phosphate) through 70 mg of 3-MPTMS-grafted MWCNTs packed into a minicolumn at 6.0 mL min{sup -1}. The elution step was carried out with 1.0 mol L{sup -1} HCl. Fourier transform infrared (FTIR) spectroscopy, scanning electron microscopy (SEM) and energy dispersive spectroscopy (EDS) were used to estimate the extent of the MWCNT chemical modification. The 3-MPTMS-grafted MWCNTs provided a 1.68 times improvement in the sensitivity of the Cd{sup 2+} FAAS determination compared to the unsilanized oxidized MWCNTs. The following parameters were obtained: preconcentration factor of 31.5, consumptive index of 0.635 mL, sample throughput of 14 h{sup -1}, and concentration efficiency of 9.46 min{sup -1}. The analytical curve was constructed in the range of 1.0-60.0 {mu}g L{sup -1} (r = 0.9988), and the detection and quantification limits were found to be 0.15 {mu}g L{sup -1} and 0.62 {mu}g L{sup -1}, respectively. Different types of water samples and cigarette sample were successfully analyzed, and the results were compared using electrothermal atomic absorption spectrometry (ETAAS) as reference technique. In addition, the accuracy of proposed method was also checked by analysis of

  14. Transluminal endovascular stent-graft for the treatment of aortic aneurysms

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Do Yun; Chang, Byung Chul; Shim, Won Heum; Cho, Seung Yun; Chung, Nam Sik; Kwon, Hyuk Moon; Lee, Young Joon; Lee, Jong Tae [Yonsei University College of Medicine, Seoul (Korea, Republic of)

    1995-09-15

    The standard treatment for aortic aneurysms is surgical replacement with a prosthetic graft. Currently there is great interest in endoluminal intervention for treatment of aortic aneurysm. The purpose of this study was to evaluate the safety and effectiveness of endoluminally placed Stent-graft for the treatment of aortic aneurysms. Transluminal endovascular Stent-graft placements were attempted in 9 patients with infra-renal aortic aneurysms(n 6), thoracic aortic aneurysm(n = 1), and aortic dissection(n = 2). The endovascular Stent-grafts were custom-designed for each patient and were constructed of self-expandable modified Gianturco Stents covered with polytetrafluroethylene. The Stent-grafts were introduced through a 16-18 French sheath and expanded to 17-30 mm in diameter. The endovascular therapy was performed using a common femoral artery cutdown with local anesthesia. The endovascular Stent-graft deployment was achieved in 7 of 9 patients. Two cases failed deployment of the Stent-graft due to iliac artery stenosis and tortousity. There were complete thrombosis of the thoracic and infra-renal aortic aneurysm surround the Stent-graft in 3 patients, and persistent leak with partial thrombosis in 2. Two patients with aortic dissection were successfully treated by obliteration of entry tears. There were no major complication associated with Stent-graft placement. These preliminary results show that transluminal endovascular Stent-grafts offer great promise and good results. Further investigation is needed to establish its long-term safety and efficacy.

  15. Transluminal endovascular stent-graft for the treatment of aortic aneurysms

    International Nuclear Information System (INIS)

    Lee, Do Yun; Chang, Byung Chul; Shim, Won Heum; Cho, Seung Yun; Chung, Nam Sik; Kwon, Hyuk Moon; Lee, Young Joon; Lee, Jong Tae

    1995-01-01

    The standard treatment for aortic aneurysms is surgical replacement with a prosthetic graft. Currently there is great interest in endoluminal intervention for treatment of aortic aneurysm. The purpose of this study was to evaluate the safety and effectiveness of endoluminally placed Stent-graft for the treatment of aortic aneurysms. Transluminal endovascular Stent-graft placements were attempted in 9 patients with infra-renal aortic aneurysms(n 6), thoracic aortic aneurysm(n = 1), and aortic dissection(n = 2). The endovascular Stent-grafts were custom-designed for each patient and were constructed of self-expandable modified Gianturco Stents covered with polytetrafluroethylene. The Stent-grafts were introduced through a 16-18 French sheath and expanded to 17-30 mm in diameter. The endovascular therapy was performed using a common femoral artery cutdown with local anesthesia. The endovascular Stent-graft deployment was achieved in 7 of 9 patients. Two cases failed deployment of the Stent-graft due to iliac artery stenosis and tortousity. There were complete thrombosis of the thoracic and infra-renal aortic aneurysm surround the Stent-graft in 3 patients, and persistent leak with partial thrombosis in 2. Two patients with aortic dissection were successfully treated by obliteration of entry tears. There were no major complication associated with Stent-graft placement. These preliminary results show that transluminal endovascular Stent-grafts offer great promise and good results. Further investigation is needed to establish its long-term safety and efficacy

  16. Anisotropic Diffusion based Brain MRI Segmentation and 3D Reconstruction

    Directory of Open Access Journals (Sweden)

    M. Arfan Jaffar

    2012-06-01

    Full Text Available In medical field visualization of the organs is very imperative for accurate diagnosis and treatment of any disease. Brain tumor diagnosis and surgery also required impressive 3D visualization of the brain to the radiologist. Detection and 3D reconstruction of brain tumors from MRI is a computationally time consuming and error-prone task. Proposed system detects and presents a 3D visualization model of the brain and tumor inside which greatly helps the radiologist to effectively diagnose and analyze the brain tumor. We proposed a multi-phase segmentation and visualization technique which overcomes the many problems of 3D volume segmentation methods like lake of fine details. In this system segmentation is done in three different phases which reduces the error chances. The system finds contours for skull, brain and tumor. These contours are stacked over and two novel methods are used to find the 3D visualization models. The results of these techniques, particularly of interpolation based, are impressive. Proposed system is tested against publically available data set [41] and MRI datasets available from MRI aamp; CT center Rawalpindi, Pakistan [42].

  17. PP films grafted with N-isopropylacrylamide and N-(3-aminopropyl) methacrylamide by gamma radiation: synthesis and characterization

    Energy Technology Data Exchange (ETDEWEB)

    Contreras-Garcia, Angel [Departamento de Quimica de Radiaciones y Radioquimica, Instituto de Ciencias Nucleares, Universidad Nacional Autonoma de Mexico, Circuito Exterior, Ciudad Universitaria, Mexico DF 04510 (Mexico); Alvarez-Lorenzo, Carmen; Concheiro, Angel [Departamento de Farmacia y Tecnologia Farmaceutica, Universidad de Santiago de Compostela, 15782-Santiago de Compostela (Spain); Bucio, Emilio, E-mail: ebucio@nucleares.unam.m [Departamento de Quimica de Radiaciones y Radioquimica, Instituto de Ciencias Nucleares, Universidad Nacional Autonoma de Mexico, Circuito Exterior, Ciudad Universitaria, Mexico DF 04510 (Mexico)

    2010-05-15

    Simultaneous grafting of N-isopropylacrylamide (NIPAAm) and N-(3-aminopropyl) methacrylamide hydrochloride (APMA) on polypropylene (PP) was investigated for obtaining interfaces that are stimuli-responsive under physiological conditions. A pre-irradiation method was optimized tuning the gamma-irradiation dose, reaction time, temperature, and monomers concentrations. FT-IR ATR and XPS analysis of the grafted copolymers evidenced a greater content in NIPAAm than in APMA; the APMA/NIPAAm ratio increasing with the concentration of APMA in the reaction medium and when the grafting was carried out in 1 M NaNO{sub 3}. The grafted films were characterized regarding their thermal properties (DSC and TGA) swelling behavior and contact angle. Immersion of the pre-irradiated films in 1 M NIPAAm/0.5 M APMA aqueous solution rendered PP-g-(1NIPAAm-r-0.5APMA) which exhibited rapid and reversible transitions showing a LCST around the physiological temperature. By contrast, a greater content in APMA enhanced the hydrophilicity and prevented the shrinking of PP-g-(1NIPAAm-r-1APMA).

  18. PP films grafted with N-isopropylacrylamide and N-(3-aminopropyl) methacrylamide by γ radiation: synthesis and characterization

    International Nuclear Information System (INIS)

    Contreras-Garcia, Angel; Alvarez-Lorenzo, Carmen; Concheiro, Angel; Bucio, Emilio

    2010-01-01

    Simultaneous grafting of N-isopropylacrylamide (NIPAAm) and N-(3-aminopropyl) methacrylamide hydrochloride (APMA) on polypropylene (PP) was investigated for obtaining interfaces that are stimuli-responsive under physiological conditions. A pre-irradiation method was optimized tuning the γ-irradiation dose, reaction time, temperature, and monomers concentrations. FT-IR ATR and XPS analysis of the grafted copolymers evidenced a greater content in NIPAAm than in APMA; the APMA/NIPAAm ratio increasing with the concentration of APMA in the reaction medium and when the grafting was carried out in 1 M NaNO 3 . The grafted films were characterized regarding their thermal properties (DSC and TGA) swelling behavior and contact angle. Immersion of the pre-irradiated films in 1 M NIPAAm/0.5 M APMA aqueous solution rendered PP-g-(1NIPAAm-r-0.5APMA) which exhibited rapid and reversible transitions showing a LCST around the physiological temperature. By contrast, a greater content in APMA enhanced the hydrophilicity and prevented the shrinking of PP-g-(1NIPAAm-r-1APMA).

  19. Preparation of Dimethylaminoethylmethacrylate Grafted Polymeric Adsorbent by Using Radiation-Induced Grafting Technique for Removal of Anions

    International Nuclear Information System (INIS)

    Kavakli, P. A.

    2006-01-01

    The development of efficient separation and purification techniques is very important from industrial, environmental and economic points of view. Polymeric materials having polyfunctional groups such as carboxylic, amide, nitrile, iminodiacetic acid, amidoxime, and ammonium groups, etc., not only possess good hydrophilic properties, but also have good ion exchange properties which make them suitable for metal recovery from aqueous solutions. Radiation induced grafting is a powerful technique capable of controlling the introduction of various functional groups to the polymeric materials, keeping the original properties and especially the mechanical strength of the base material, and thus, allowing the synthesis of more stable polymeric adsorbents. The main objective of this study was to develop special polymeric adsorbents to remove NOx and PO 4 anions from aqueous systems. For this purpose, a novel nonwoven fabric was prepared by radiation-induced graft polymerization of imethylaminoethylmethacrylate (DMAEMA) onto polypropylene coated polyethylene nonwoven fabric. The trunk polymer was irradiated by electron beam at a voltage of 2 MeV and a current of 3 mA in a nitrogen atmosphere at dry-ice temperature at different doses. The degree of grafting was determined as a function of the total dose, monomer concentration, temperature, and reaction time. It was found that the degree of grafting of grafted polymer was greatly affected by reaction conditions. Grafting conditions were optimized, and about 150 % degree of grafting samples was used for further experiments. DMAEMA grafted polymer was later protonated by using acid solution to prepare adsorbent for the removal of anions. Adsorption experiments were performed in column mode for removal of phosphate. Approximately 2000 bed volumes of phosphate-free water can be produced from 10 ppb phosphate solution at high space velocity

  20. Radioinduced grafting of acrylic acid on expanded polystyrene matrices

    International Nuclear Information System (INIS)

    Postolache, C.; Simion, Corina; Dragomir, A.; Ponta, C.; Chirvasoiu, G.; Postolache, Carmen

    1998-01-01

    The unfixed surface radioactive contamination for low energy β radionuclides ( 3 H and 14 C) is determined by wiping the checked surfaces with sponge of absorbent materials. The activity built up by this sponge is measured by a liquid scintillator spectrometer. In this work, a method of obtaining sponges of expanded polystyrene with hydrophobic surface by radioinduced grafting of the acrylic acid is presented. These sponges have diameters of 28 mm, thicknesses of 1.5 - 2 mm and density of 22 mg/cm 3 . The samples were immersed in a grafting solution with the following composition: acrylic acid 30%, Cu SO 4 1%; water 69% which were deeply impregnated in repeated operations under vacuum and pressure conditions, respectively. Finally, the samples were exposed to γ radiation emitted by a 60 Co source (IETI 10 000 - IFIN-HH). The dose rates were 0.3, 0.5 and 1 Mrad/h. The range of the absorbed doses was 1 - 25 Mrad. The yields of radiochemical grafting have been determined by gravimetric, spectrophotometric and radiometric methods. The grafting agent used was 3 H labelled acrylic acid. The solvation capacity and the quenching characteristics of the grafted sponges in liquid scintillators, as well as the sampling yields have been analyzed as function of irradiation procedure and the percentage of grafted acrylic fragments. The superficial grafting of the acrylic acid has been carried out by the mentioned technique, leading to the increase of the wiping efficiency of the unfixed surface contaminating activity, without changes of polymer solubility in liquid scintillators and without the perturbation of the radioactivity detection process. (authors)

  1. Contribution of S4 segments and S4-S5 linkers to the low-voltage activation properties of T-type CaV3.3 channels.

    Directory of Open Access Journals (Sweden)

    Ana Laura Sanchez-Sandoval

    Full Text Available Voltage-gated calcium channels contain four highly conserved transmembrane helices known as S4 segments that exhibit a positively charged residue every third position, and play the role of voltage sensing. Nonetheless, the activation range between high-voltage (HVA and low-voltage (LVA activated calcium channels is around 30-40 mV apart, despite the high level of amino acid similarity within their S4 segments. To investigate the contribution of S4 voltage sensors for the low-voltage activation characteristics of CaV3.3 channels we constructed chimeras by swapping S4 segments between this LVA channel and the HVA CaV1.2 channel. The substitution of S4 segment of Domain II in CaV3.3 by that of CaV1.2 (chimera IIS4C induced a ~35 mV shift in the voltage-dependence of activation towards positive potentials, showing an I-V curve that almost overlaps with that of CaV1.2 channel. This HVA behavior induced by IIS4C chimera was accompanied by a 2-fold decrease in the voltage-dependence of channel gating. The IVS4 segment had also a strong effect in the voltage sensing of activation, while substitution of segments IS4 and IIIS4 moved the activation curve of CaV3.3 to more negative potentials. Swapping of IIS4 voltage sensor influenced additional properties of this channel such as steady-state inactivation, current decay, and deactivation. Notably, Domain I voltage sensor played a major role in preventing CaV3.3 channels to inactivate from closed states at extreme hyperpolarized potentials. Finally, site-directed mutagenesis in the CaV3.3 channel revealed a partial contribution of the S4-S5 linker of Domain II to LVA behavior, with synergic effects observed in double and triple mutations. These findings indicate that IIS4 and, to a lesser degree IVS4, voltage sensors are crucial in determining the LVA properties of CaV3.3 channels, although the accomplishment of this function involves the participation of other structural elements like S4-S5 linkers.

  2. Contribution of S4 segments and S4-S5 linkers to the low-voltage activation properties of T-type CaV3.3 channels

    Science.gov (United States)

    Sanchez-Sandoval, Ana Laura; Herrera Carrillo, Zazil; Díaz Velásquez, Clara Estela; Delgadillo, Dulce María; Rivera, Heriberto Manuel

    2018-01-01

    Voltage-gated calcium channels contain four highly conserved transmembrane helices known as S4 segments that exhibit a positively charged residue every third position, and play the role of voltage sensing. Nonetheless, the activation range between high-voltage (HVA) and low-voltage (LVA) activated calcium channels is around 30–40 mV apart, despite the high level of amino acid similarity within their S4 segments. To investigate the contribution of S4 voltage sensors for the low-voltage activation characteristics of CaV3.3 channels we constructed chimeras by swapping S4 segments between this LVA channel and the HVA CaV1.2 channel. The substitution of S4 segment of Domain II in CaV3.3 by that of CaV1.2 (chimera IIS4C) induced a ~35 mV shift in the voltage-dependence of activation towards positive potentials, showing an I-V curve that almost overlaps with that of CaV1.2 channel. This HVA behavior induced by IIS4C chimera was accompanied by a 2-fold decrease in the voltage-dependence of channel gating. The IVS4 segment had also a strong effect in the voltage sensing of activation, while substitution of segments IS4 and IIIS4 moved the activation curve of CaV3.3 to more negative potentials. Swapping of IIS4 voltage sensor influenced additional properties of this channel such as steady-state inactivation, current decay, and deactivation. Notably, Domain I voltage sensor played a major role in preventing CaV3.3 channels to inactivate from closed states at extreme hyperpolarized potentials. Finally, site-directed mutagenesis in the CaV3.3 channel revealed a partial contribution of the S4-S5 linker of Domain II to LVA behavior, with synergic effects observed in double and triple mutations. These findings indicate that IIS4 and, to a lesser degree IVS4, voltage sensors are crucial in determining the LVA properties of CaV3.3 channels, although the accomplishment of this function involves the participation of other structural elements like S4-S5 linkers. PMID:29474447

  3. Contribution of S4 segments and S4-S5 linkers to the low-voltage activation properties of T-type CaV3.3 channels.

    Science.gov (United States)

    Sanchez-Sandoval, Ana Laura; Herrera Carrillo, Zazil; Díaz Velásquez, Clara Estela; Delgadillo, Dulce María; Rivera, Heriberto Manuel; Gomora, Juan Carlos

    2018-01-01

    Voltage-gated calcium channels contain four highly conserved transmembrane helices known as S4 segments that exhibit a positively charged residue every third position, and play the role of voltage sensing. Nonetheless, the activation range between high-voltage (HVA) and low-voltage (LVA) activated calcium channels is around 30-40 mV apart, despite the high level of amino acid similarity within their S4 segments. To investigate the contribution of S4 voltage sensors for the low-voltage activation characteristics of CaV3.3 channels we constructed chimeras by swapping S4 segments between this LVA channel and the HVA CaV1.2 channel. The substitution of S4 segment of Domain II in CaV3.3 by that of CaV1.2 (chimera IIS4C) induced a ~35 mV shift in the voltage-dependence of activation towards positive potentials, showing an I-V curve that almost overlaps with that of CaV1.2 channel. This HVA behavior induced by IIS4C chimera was accompanied by a 2-fold decrease in the voltage-dependence of channel gating. The IVS4 segment had also a strong effect in the voltage sensing of activation, while substitution of segments IS4 and IIIS4 moved the activation curve of CaV3.3 to more negative potentials. Swapping of IIS4 voltage sensor influenced additional properties of this channel such as steady-state inactivation, current decay, and deactivation. Notably, Domain I voltage sensor played a major role in preventing CaV3.3 channels to inactivate from closed states at extreme hyperpolarized potentials. Finally, site-directed mutagenesis in the CaV3.3 channel revealed a partial contribution of the S4-S5 linker of Domain II to LVA behavior, with synergic effects observed in double and triple mutations. These findings indicate that IIS4 and, to a lesser degree IVS4, voltage sensors are crucial in determining the LVA properties of CaV3.3 channels, although the accomplishment of this function involves the participation of other structural elements like S4-S5 linkers.

  4. Synthesis of new hybrid sorbent by grafting 2,6-diacetyl pyridine ...

    Indian Academy of Sciences (India)

    23–25 Zeolites are a type of porous materials having crystalline .... removal of solvent through filtration and drying in hot air oven at 60. ◦. C for 12h. The scheme 2 shows the mechanism of grafting of 2,6-DAP-PA onto β-zeolite. 2.5 Preparation of ...

  5. Fabrication of TiO_2 nanorod assembly grafted rGO (rGO@TiO_2-NR) hybridized flake-like photocatalyst

    International Nuclear Information System (INIS)

    Lv, Kangle; Fang, Shun; Si, Lingling; Xia, Yang; Ho, Wingkei; Li, Mei

    2017-01-01

    Highlights: • TiO_2 nanorod assembly grafted with GO hybrid was successfully fabricated. • TiO_2 nanorods can reduce the aggregation of TiO_2 nanoparticles on graphene. • This unique structure facilitates the injection of electron from TiO_2 to graphene. - Abstract: To efficiently separate the photo-generated electron–hole pairs of TiO_2 hybrid, anatase TiO_2 nanorod assembly grafted reduced graphene oxides (rGO@TiO_2-NR) hybrid was successfully fabricated using potassium titanium oxalate (PTO) and graphene oxides (GO) as starting materials and diethylene glycol (DEG) as reductant. The effect of GO content on the structure and photocatalytic activity of rGO@TiO_2-NR composite was systematically studied. Results show that, in the absence of GO, only TiO_2 microsphere assembly is obtained from TiO_2 nanorods. The presence of GO results in the formation of a flake-like TiO_2-nanorod-assembled grafted rGO hybrid. The photocatalytic activity of rGO@TiO_2-NR composite increases first and then decreases with increase in the amount of GO from 0 wt.% to 10 wt.%. The hybridized S4 sample prepared with 4 wt.% GO possesses the highest photocatalytic activity with a constant rate of 0.039 min"−"1 in the photocataytic degradation of Brilliant X-3B dye (X3B); this sample was enhanced more than three times when compared with pure TiO_2 sample (0.012 min"−"1). The enhanced photocatalytic activity of the rGO@TiO_2-NR hybrid was attributed to the strong interaction between TiO_2 nanorods and rGO. The unique hierarchical structure of 1D nanorod assembly TiO_2–rGO flakes facilitates the injection and transfer of photo-generated electrons from TiO_2 to graphene, thus retarding the recombination of electron–hole pairs and enhancing the photocatalytic activity. The enlarged BET surface areas, not only increasing the number of active sites, but also facilitating the adsorption of the dye, and improved light-harvesting ability also contribute to the enhanced photoreactivity

  6. Radiation induced graft copolymerization of jute fibre

    International Nuclear Information System (INIS)

    Al-Siddique, F.R.; Khan, A.U.; Sheikh, R.A.

    1983-01-01

    Graft copolymerized jute fibres (GCJF) were prepared by γ-ray induced graft copolymerization of various monomers onto bleached and de-waxed jute samples. The effect of γ-ray dose on the tendency of various monomers to form graft co-polymer was studied. It was found that the tendency decreases as follows: methylmethacrylate (MMA)>acrylonitrile (AN)>styrene (STY)>vinylacetate (VA). When the effect of monomer concentration on the formation of graft co-polymer was studied, it was found that a mixture of AN and STY gave a higher amount of grafting than what was observed for STY or AN alone, when used at a comparable concentration. A study on the effect of concentration of methyl alcohol (a swelling agent for jute) on the tendency of the monomers to form graft co-polymer showed that although there is no effect when only AN is used, an appreciable effect is observed if AN is mixed with STY. In the later case the tendency of graft co-polymerization increases with the increase of CH 3 OH concentration. It was further observed that the increase of CH 3 OH also has a positive influence on MMA to form graft co-polymer in the range of 40-90% CH 3 OH. The affinity of GCJF towards moisture has been found to decrease with the increase of polymer loading onto jute. The presence of swelling agents during graft copolymer formation was also found to decrease the affinity of GCJF towards moisture. (author)

  7. Electroosmotic Flow in Mixed Polymer Brush-Grafted Nanochannels

    Directory of Open Access Journals (Sweden)

    Qianqian Cao

    2016-12-01

    Full Text Available Mixed polymer brush-grafted nanochannels—where two distinct species of polymers are alternately grafted on the inner surface of nanochannels—are an interesting class of nanostructured hybrid materials. By using a coarse-grained molecular dynamics simulation method, we are able to simulate the electrokinetic transport dynamics of the fluid in such nanochannels as well as the conformational behaviors of the mixed polymer brush. We find that (1 the brush adopts vertically-layered and longitudinally-separated structures due to the coupling of electroosmotic flow (EOF and applied electric field; (2 the solvent quality affects the brush conformations and the transport properties of the EOF; (3 the EOF flux non-monotonically depends on the grafting density, although the EOF velocity in the central region of the channel monotonically depends on the grafting density.

  8. Reduction of indium-111 platelet deposition on Dacron vascular grafts in humans by aspirin plus dipyridamole

    International Nuclear Information System (INIS)

    Stratton, J.R.; Ritchie, J.L.

    1986-01-01

    Aspirin plus dipyridamole reduces platelet accumulation on short-term Dacron vascular grafts in man. To determine whether drug inhibition of platelet deposition is sustained on older grafts, we studied 18 men aged 41 to 87 years who had Dacron aortic bifurcation grafts in place a mean of 43.4 months (range 9.8 to 121.0) before and during short-term therapy with aspirin (325 mg tid) plus dipyridamole (75 mg tid). During both the baseline and drug studies, indium-111 ( 111 In) platelet deposition was quantitated by two techniques, standard planar imaging performed at 24, 48, and 72 hr after injection of platelets and single photon emission computed tomographic imaging performed at 24 and 72 hr after injection. All analyses were performed in a blinded fashion. On both the planar and tomographic images, platelet accumulation on the graft was quantitated by a graft/blood ratio that compared activity in the graft to simultaneously collected whole blood 111 In platelet activity. Aspirin plus dipyridamole reduced the tomographic graft/blood ratio at 24 hr (20.6 +/- 3.5 vs 17.3 +/- 2.5) (+/-SEM) and at 72 hr (29.0 +/- 4.8 vs 25.0 +/- 4.1) after injection of platelets (p = .02). Dacron vascular grafts. Similarly, the planar graft/blood ratio was reduced at 24 hr (2.7 +/- 0.5 vs 2.4 +/- 0.5), 48 hr (3.7 +/- 0.9 vs 3.1 +/- 0.7), and 72 hr (4.0 +/- 0.9 vs 3.6 +/- 0.8) (p = .04). We conclude that aspirin (325 mg tid) plus dipyridamole (75 mg tid) reduces platelet accumulation on long-term Dacron vascular grafts

  9. Bridging Graft in Irreparable Massive Rotator Cuff Tears: Autogenic Biceps Graft versus Allogenic Dermal Patch Graft.

    Science.gov (United States)

    Rhee, Sung Min; Oh, Joo Han

    2017-12-01

    Few comparative studies have reported on the use of biologic grafts for irreparable massive rotator cuff tears. The purpose of this study was to assess the results of arthroscopic bridging graft in irreparable massive rotator cuff tears using an autogenic long head of biceps tendon (LHBT) or an allogenic dermal patch (ADP). We retrospectively reviewed 24 patients treated using the LHBT (group I) and eight patients with complete rupture of the LHBT treated using an ADP (group II) since 2011. Preoperative Goutallier's fatty degeneration, range of motion (ROM), visual analogue scale (VAS) for pain, American Shoulder and Elbow Surgeons (ASES) score, and Quick Disabilities of the Arm, Shoulder, and Hand (DASH) score were assessed and healing failure was evaluated at 1 year after surgery by ultrasonography or magnetic resonance imaging. The mean fatty degeneration in groups I and II was 3.9 and 3.6 for the supraspinatus ( p = 0.288), 2.7 and 2.9 for the infraspinatus ( p = 0.685), 0.9 and 1.3 for the subscapularis ( p = 0.314), and 1.3 and 3.0 for the teres minor ( p = 0.005), respectively. Subscapularis tears were found in 8 patients (33.3%) in group I and in 7 patients (87.5%) in group II ( p = 0.023). Mean ROMs and functional scores improved significantly in group I (forward flexion: 121.7° to 153.3°, p = 0.010; external rotation: 32.7° to 52.7°, p = 0.001; external rotation at 90°: 63.3° to 74.5°, p = 0.031; internal rotation: T10.5 to T9.3, p = 0.045; VAS: 7.0 to 1.1, p rotator cuff tears, especially in patients with severe fatty degeneration in the teres minor or combined biceps and subscapularis tears.

  10. Reconstruction of large upper eyelid defects with a free tarsal plate graft and a myocutaneous pedicle flap plus a free skin graft.

    Science.gov (United States)

    Toft, Peter B

    2016-01-01

    To review and present the results of a one-step method employing a free tarsal plate graft and a myocutaneous pedicle flap plus a free skin graft for reconstruction of large upper eyelid defects after tumour surgery. This was a retrospective case-series of 8 patients who underwent reconstruction of the upper eyelid after tumour removal. The horizontal defect involved 50-75% of the lid (3 pts.), more than 75% (3 pts.), and more than 75% plus the lateral canthus (2 pts.). The posterior lamella was reconstructed with contralateral upper eyelid tarsal plate. The anterior lamella was reconstructed with a laterally based myocutaneous pedicle flap in 7 patients, leaving a raw surface under the brow which was covered with a free skin graft. In 1 patient with little skin left under the brow, the anterior lamella was reconstructed with a bi-pedicle orbicularis muscle flap together with a free skin graft. All patients healed without necrosis, did not suffer from lagophthalmos, achieved reasonable cosmesis, and did not need lubricants. In one patient, a contact lens was necessary for three weeks because of corneal erosion. One patient still needs a contact lens 3 months after excision to avoid eye discomfort. Large upper eyelid defects can be reconstructed with a free tarsal plate graft and a laterally based myocutaneous pedicle flap in combination with a free skin graft. Two-step procedures can probably be avoided in most cases.

  11. Bifunctional groups grafted polyethersulfone magnetic beads for selective sequestration of plutonium

    International Nuclear Information System (INIS)

    Paul, Sumana; Aggarwal, S.K.; Pandey, A.K.

    2014-01-01

    The present study involves synthesis of polyethersulfone (PES) beads grafted with two different monomers viz. 2-hydroxyethylmethacrylate phosphoric acid ester (HEMP) and 2-acrylamido-2-methyl-1-propane sulphonic acid (AMPS) by photo-induced free radical polymerization method. The selection of bifunctional polymer was based on our previous studies, which indicated its efficacy for selective preconcentration of Pu from 3-4 mol L -1 HNO 3 . The HEMP-co-AMPS grafted PES beads were used for selective extraction of plutonium from dissolver solution

  12. Ionic membranes obtained by radiation - induced graft copolymerization, II-characterization and waste treatment. Vol. 3

    Energy Technology Data Exchange (ETDEWEB)

    Ali, A M.I.; Nowier, H G; Aly, H F [National Center for Radiation and Technology, Atomic Energy Authority, Cairo, (Egypt); Abd El-Rehim, H A; Hegazy, E A [Hot Laboratories Center, Atomic Energy Authority, Cairo (Egypt)

    1996-03-01

    Ionic membranes were prepared by radiation-induced grafting of acrylic acid onto low density polyethylene films. To elucidate the possibility of practical use, a study was made for the characterization of the grafted and chemically treated mechanisms. The selectivity of such prepared membranes towards the chelation or absorption of different alkali metals was investigated, to find that the higher affinity was observed for K{sup +}, Na{sup +} and Li{sup +} ions compared to other alkali metals used. The metal uptake percent was determined using different techniques; flame photometer, and X-ray fluorescence (XRF). The uptake of metal from its feed solution by the the grafted membrane increased as the degree of grating increased, i.e. it is directly proportional to the functional carboxylic acid groups in the graft copolymer. As a consequence, the electrical conductivity of metal feed solution decreased during such process of metal chelation by membrane. The higher the grafting degree of membrane, the lower the electrical conductivity of metal feed solutions observed. the changes in thermal properties of the membranes prepared were investigated and characterized using differential scanning calorimetry, (DSC), and thermal gravimetric analysis (TGA). The thermal stability of these membranes increased with degree of grafting due to the formation of cross linked network structure via hydrogen bonding. furthermore, such stability is enhanced for the alkali-treated membranes even at high elevated temperatures. The membranes prepared showed a great promise for possible use in some practical applications such as metal waste treatment. 3 figs., 5 tabs.

  13. Guiding Device for Precision Grafting of Peripheral Nerves in Complete Thoracic Spinal Cord Injury: Design and Sizing for Clinical Trial

    Directory of Open Access Journals (Sweden)

    Arvid Frostell

    2018-05-01

    Full Text Available BackgroundIn an effort to translate preclinical success in achieving spinal cord regeneration through peripheral nerve grafts, this study details the design and sizing of a guiding device for precision grafting of peripheral nerves for use in a clinical trial in complete (AIS-A thoracic spinal cord injury (SCI. The device’s design and sizing are compared to a simulation of human spinal cord sizes based on the best available data.MethodsSpinal cord segmental sizes were generated by computer simulation based on data from a meta-analysis recently published by our group. Thoracic segments T2–T12 were plotted, and seven elliptical shapes were positioned across the center of the distribution of sizes. Geometrical measures of error-of-fit were calculated. CAD modeling was used to create cranial and caudal interfaces for the human spinal cord, aiming to guide descending white matter tracts to gray matter at the caudal end of the device and ascending white matter tracts to gray matter at the cranial end of the device. The interfaces were compared qualitatively to the simulated spinal cord sizes and gray-to-white matter delineations.ResultsThe mean error-of-fit comparing simulated spinal cord segments T2–T12 to the best elliptical shape was 0.41 and 0.36 mm, and the 95th percentile was found at 1.3 and 0.98 mm for transverse and anteroposterior diameter, respectively. A guiding device design was reached for capturing the majority of corticospinal axons at the cranial end of the device and guiding them obliquely to gray matter at the caudal end of the device. Based on qualitative comparison, the vast majority of spinal cord sizes generated indicate an excellent fit to the device’s interfaces.ConclusionA set of SCI guiding devices of seven sizes can cover the variability of human thoracic spinal cord segments T2–T12 with an acceptable error-of-fit for the elliptical shape as well as guiding channels. The computational framework developed can

  14. The Primary Patency and Fracture Rates of Self-Expandable Nitinol Stents Placed in the Popliteal Arteries, Especially in the P2 and P3 Segments, in Korean Patients

    Energy Technology Data Exchange (ETDEWEB)

    Chang, Il Soo; Chee, Hyun Keun; Park, Sang Woo; Yun, Ik Jin; Hwang, Jae Joon; Lee, Song Am; Kim, Jun Seok; Chang, Seong Hwan; Jung, Hong Geun [Konkuk University Hospital, Seoul (Korea, Republic of)

    2011-04-15

    We wanted to evaluate the status of self-expandable nitinol stents implanted in the P2 and P3 segments of the popliteal artery in Korean patients. We retrospectively analyzed 189 consecutive patients who underwent endovascular treatment for steno occlusive lesions in the femoropopliteal artery from July 2003 to March 2009, and 18 patients who underwent stent placement in popliteal arterial P2 and P3 segments were finally enrolled. Lesion patency was evaluated by ultrasound or CT angiography, and stent fracture was assessed by plain X-rays at 1, 3, 6 and 12 months and annually thereafter. At the 1-month follow-up, stent fracture (Type 2) was seen in one limb (up to P3, 1 of 18, 6%) and it was identified in seven limbs at the 3-month follow-up (Type 2, Type 3, Type 4) (n = 1: up to P2: n = 6: P3). At the 6-month follow-up, one more fracture (Type 1) (up to P3) was noted. At the 1-year follow-up, there were no additional stent fractures. Just four limbs (up to P2) at the 2-year follow-up did not have stent fracture. The primary patency was 94%, 61% and 44% at 1, 3 and 6 months, respectively, and the group with stent implantation up to P3 had a higher fracture rate than that of the group that underwent stenting up to P2 (p < 0.05). We suggest that stent placement up to the popliteal arterial P3 segment and over P2 in an Asian population can worsen the stent patency owing to stent fracture. It may be necessary to develop a stent design and structure for the Asian population that can resist the bending force in the knee joint

  15. Desalination by electrodialysis with the ion-exchange membrane prepared by radiation-induced graft polymerization

    Energy Technology Data Exchange (ETDEWEB)

    Choi, Seong-Ho; Han Jeong, Young; Jeong Ryoo, Jae; Lee, Kwang-Pill E-mail: kplee@kyungpook.ac.kr

    2001-07-01

    Ion-exchange membranes modified with the triethylamine [-N(CH{sub 2}CH{sub 3}){sub 3}] and phosphoric acid (-PO{sub 3} H) groups were prepared by radiation-induced grafting of glycidyl methacrylate (GMA) onto the polyolefin nonwavon fabric (PNF) and subsequent chemical modification of poly(GMA) graft chains. The physical and chemical properties of the GMA-grafted PNF and the PNF modified with ion-exchange groups were investigated by SEM, XPS, TGA, and DSC. Furthermore, electrochemical properties such as specific electric resistance, transport number of K{sup +}, and desalination were examined. The grafting yield increased with increasing reaction time and reaction temperature. The maximum grafting yield was obtained with 40% (vol.%) monomer concentration in dioxane at 60 deg. C. The content of the cation- and anion-exchange group increased with increasing grafting yield. Electrical resistance of the PNF modified with TEA and -PO{sub 3} H group decreased, while the water uptake (%) increased with increasing ion-exchange group capacities. Transport number of the PNF modified with ion-exchange group were the range of ca. 0.82-0.92. The graft-type ion-exchange membranes prepared by radiation-induced graft copolymerization were successfully applied as separators for electrodialysis. (author)

  16. One Year Outcomes of 101 BeGraft Stent Grafts used as Bridging Stents in Fenestrated Endovascular Repairs.

    Science.gov (United States)

    Spear, Rafaelle; Sobocinski, Jonathan; Hertault, Adrien; Delloye, Matthieu; Azzauiu, Richard; Fabre, Dominique; Haulon, Stéphan

    2018-04-01

    To evaluate the outcomes of the second generation BeGraft balloon expandable covered stent Graft System (Bentley InnoMed, Hechingen, Germany) implanted as bridging stent grafts during fenestrated endovascular aortic repair (FEVAR) of complex aneurysms. This was a single centre prospective study including all consecutive patients treated by FEVAR performed with second generation BeGraft stent grafts as bridging stents. Demographics of patients, diameter and length of the bridging stent grafts, technical success, re-interventions, occlusions, post-operative events, and imaging (Cone Beam CT and/or CT scan, and contrast enhanced ultrasound) were prospectively collected in an electronic database. Duplex ultrasound was performed before discharge and at 6 month follow-up. At 1 year, patients were evaluated clinically and by imaging (CT and ultrasound). Between November 2015 and September 2016, 39 consecutive patients (one woman) were treated with custom made fenestrated endografts (2-5 fenestrations) for complex aneurysms or type 1 endoleak after EVAR, using a variety of bridging stents including the BeGraft. All 101 BeGraft stent grafts were successfully delivered and deployed. There was no in hospital mortality. Early fenestration patency rate was 99% (96/97); the sole target vessel post-operative occlusion was secondary to a dissection of the renal artery distal to the stent. Complementary stenting was unsuccessful in recovering renal artery patency; bilateral renal stent occlusion was observed in the same patient on a CT scan performed 2 months after the procedure. He required post-operative dialysis. No additional renal impairment was observed. During follow-up (median 13 months [11-15]), all fenestrations stented with BeGraft stent grafts remained patent (95/97, 98%). One type 1b endoleak was detected and treated (2.6%). BeGraft stent grafts used as bridging stents during FEVAR are associated with favourable outcomes at 1 year follow-up. Long-term follow-up is

  17. Arthroscopic Latarjet Techniques: Graft and Fixation Positioning Assessed With 2-Dimensional Computed Tomography Is Not Equivalent With Standard Open Technique.

    Science.gov (United States)

    Neyton, Lionel; Barth, Johannes; Nourissat, Geoffroy; Métais, Pierre; Boileau, Pascal; Walch, Gilles; Lafosse, Laurent

    2018-05-19

    To analyze graft and fixation (screw and EndoButton) positioning after the arthroscopic Latarjet technique with 2-dimensional computed tomography (CT) and to compare it with the open technique. We performed a retrospective multicenter study (March 2013 to June 2014). The inclusion criteria included patients with recurrent anterior instability treated with the Latarjet procedure. The exclusion criterion was the absence of a postoperative CT scan. The positions of the hardware, the positions of the grafts in the axial and sagittal planes, and the dispersion of values (variability) were compared. The study included 208 patients (79 treated with open technique, 87 treated with arthroscopic Latarjet technique with screw fixation [arthro-screw], and 42 treated with arthroscopic Latarjet technique with EndoButton fixation [arthro-EndoButton]). The angulation of the screws was different in the open group versus the arthro-screw group (superior, 10.3° ± 0.7° vs 16.9° ± 1.0° [P open inferior screws (P = .003). In the axial plane (level of equator), the arthroscopic techniques resulted in lateral positions (arthro-screw, 1.5 ± 0.3 mm lateral [P open technique (0.9 ± 0.2 mm medial). At the level of 25% of the glenoid height, the arthroscopic techniques resulted in lateral positions (arthro-screw, 0.3 ± 0.3 mm lateral [P open technique (1.0 ± 0.2 mm medial). Higher variability was observed in the arthro-screw group. In the sagittal plane, the arthro-screw technique resulted in higher positions (55% ± 3% of graft below equator) and the arthro-EndoButton technique resulted in lower positions (82% ± 3%, P open technique (71% ± 2%). Variability was not different. This study shows that the position of the fixation devices and position of the bone graft with the arthroscopic techniques are statistically significantly different from those with the open technique with 2-dimensional CT assessment. In the sagittal plane, the arthro-screw technique provides the highest

  18. Single-Center Experience Using Marginal Liver Grafts in Korea.

    Science.gov (United States)

    Park, P-J; Yu, Y-D; Yoon, Y-I; Kim, S-R; Kim, D-S

    2018-05-01

    Liver transplantation (LT) is an established therapeutic modality for patients with end-stage liver disease. The use of marginal donors has become more common worldwide due to the sharp increase in recipients, with a consequent shortage of suitable organs. We analyzed our single-center experience over the last 8 years in LT to evaluate the outcomes of using so-called "marginal donors." We retrospectively analyzed the database of all LTs performed at our institution from 2009 to 2017. Only patients undergoing deceased-donor LTs were analyzed. Marginal grafts were defined as livers from donors >60 years of age, livers from donors with serum sodium levels >155 mEq, graft steatosis >30%, livers with cold ischemia time ≥12 hours, livers from donors who were hepatitis B or C virus positive, livers recovered from donation after cardiac death, and livers split between 2 recipients. Patients receiving marginal grafts (marginal group) were compared with patients receiving standard grafts (standard group). A total of 106 patients underwent deceased-donor LT. There were 55 patients in the standard group and 51 patients in the marginal group. There were no significant differences in terms of age, sex, Model for End-Stage Liver Disease score, underlying liver disease, presence of hepatocellular carcinoma, and hospital stay between the 2 groups. Although the incidence of acute cellular rejection, cytomegalovirus infection, and postoperative complications was similar between the 2 groups, the incidence of early allograft dysfunction was higher in the marginal group. With a median follow-up of 26 months, the 1-, 3-, and 5-year overall and graft (death-censored) survivals in the marginal group were 85.5%, 75%, and 69.2% and 85.9%, 83.6%, and 77.2%, respectively. Patient overall survival and graft survival (death-censored) were significantly lower in the marginal group (P = .023 and P = .048, respectively). On multivariate analysis, receiving a marginal graft (hazard ratio [HR

  19. Amino acids grafting of Ar+ ions modified PE

    International Nuclear Information System (INIS)

    Svorcik, V.; Hnatowicz, V.; Stopka, P.; Bacakova, L.; Heitz, J.; Oechsner, R.; Ryssel, H.

    2001-01-01

    Polyethylene (PE) was irradiated with 63 keV Ar + ions to the fluences from 1x10 12 to 3x10 15 cm -2 and then grafted at room temperature from water solution with amino acids (alanine, leucine). Using various spectroscopic techniques (UV-VIS, FTIR, RBS and EPR) it was shown that the amino acids penetrate into PE where they are eventually captured either on double bonds or on free radicals created by the ion irradiation. Grafting with amino acids in the whole specimen layer modified by irradiation is observed. The ion-beam-modified and amino-acid grafted PE is supposed to exhibit increased biocompatibility. (author)

  20. Autogenous Partial Bone Chip Grafting on the Exposed Inferior Alveolar Nerve After Cystic Enucleation.

    Science.gov (United States)

    Seo, Mi Hyun; Eo, Mi Young; Cho, Yun Ju; Kim, Soung Min; Lee, Suk Keun

    2018-03-01

    This prospective study evaluated the clinical effectiveness of the new approach of partial autogenous bone chip grafts for the treatment of mandibular cystic lesions related to the inferior alveolar nerve (IAN). A total of 38 patients treated for mandibular cysts or benign tumors were included in this prospective study and subsequently divided into 3 groups depending on the bone grafting method used: cystic enucleation without a bone graft (group 1), partial bone chip graft covering the exposed IAN (group 2), and autogenous bone graft covering the entire defect (group 3). We evaluated the symptoms, clinical signs, and radiographic changes using dental panorama preoperatively, immediate postoperatively, and at 1, 3, 6, and 12 months postoperatively. Radiographic densities were compared using Adobe Photoshop CS5 (Adobe Systems Inc., San Jose, CA). Repeated measures analysis of variance was used for statistical evaluation with SPSS 22.0 (SPSS Inc, Chicago, IL), and P < 0.05 was considered statistically significant.Radiopacities were the most increased at 1 year postoperative in group 3; groups 2 and 3 did not show statistically significant differences, whereas groups 1 and 3 were statistically significant. In terms of radiographic bone healing with clinical regeneration of the exposed IAN, healing occurred in all patients, although the best healing was achieved in group 2.This autogenous partial bone chip grafting procedure to cover the exposed IAN is suggested as a new surgical protocol for the treatment of cystic lesions associated with the IAN.

  1. [Comparison of the grafting technique in treatment of thoracolumbar burst fractures:transpedicular intracorporeal versus posterolateral].

    Science.gov (United States)

    Li, Li; Shi, Ya-Min; Hou, Shu-Xun; Wang, Hua-Dong; Guo, Ji-Dong

    2011-02-01

    To retrospectively investigate the outcome of transpedicular intracorporeal grafting and posterolateral grafting in treatment of thoracolumbar burst fractures. Forty-six patients treated with transpedicular intracorporeal grafting from January 1999 to December 2009 and followed up for 19-119 months (average 67 ± 13 months) were reviewed retrospectively, and were compared with 18 patients who had underwent posterolateral fusion during the same period through radiographic analysis. Radiographic measurements included Cobb angle, vertebral wedge angle (VWA), ratio between anterior and posterior vertebral height (APHR), upper inter-vertebral angle, lower inter-vertebral angle on X-ray, CT and MRI. In transpedicular intracorporeal grafting group, the VWA was corrected from 27.2° ± 6.5° to 7.0° ± 3.0° and the APHR from (53.3 ± 11.8)% to (92.3 ± 2.4)%. In posterolateral fusion group, the VWA was corrected from 23.9° ± 4.4° to 8.8° ± 2.1° and the APHR from (60.7 ± 10.0)% to (88.5 ± 3.3)%. Transpedicular intracorporeal grafting group showed better postoperative correction results than posterolateral fusion group (P < 0.05), and had less loss of correction of Cobb angle, VWA and APHR at final follow-up (P < 0.05). The transpedicular intracorporeal grafting can improve injured vertebral body morphology recovery better than posterolateral bone grafting, but can not prevent the late loss of correction after implant removal.

  2. Accuracy of estimation of graft size for living-related liver transplantation: first results of a semi-automated interactive software for CT-volumetry.

    Directory of Open Access Journals (Sweden)

    Theresa Mokry

    Full Text Available To evaluate accuracy of estimated graft size for living-related liver transplantation using a semi-automated interactive software for CT-volumetry.Sixteen donors for living-related liver transplantation (11 male; mean age: 38.2±9.6 years underwent contrast-enhanced CT prior to graft removal. CT-volumetry was performed using a semi-automated interactive software (P, and compared with a manual commercial software (TR. For P, liver volumes were provided either with or without vessels. For TR, liver volumes were provided always with vessels. Intraoperative weight served as reference standard. Major study goals included analyses of volumes using absolute numbers, linear regression analyses and inter-observer agreements. Minor study goals included the description of the software workflow: degree of manual correction, speed for completion, and overall intuitiveness using five-point Likert scales: 1--markedly lower/faster/higher for P compared with TR, 2--slightly lower/faster/higher for P compared with TR, 3--identical for P and TR, 4--slightly lower/faster/higher for TR compared with P, and 5--markedly lower/faster/higher for TR compared with P.Liver segments II/III, II-IV and V-VIII served in 6, 3, and 7 donors as transplanted liver segments. Volumes were 642.9±368.8 ml for TR with vessels, 623.8±349.1 ml for P with vessels, and 605.2±345.8 ml for P without vessels (P<0.01. Regression equations between intraoperative weights and volumes were y = 0.94x+30.1 (R2 = 0.92; P<0.001 for TR with vessels, y = 1.00x+12.0 (R2 = 0.92; P<0.001 for P with vessels, and y = 1.01x+28.0 (R2 = 0.92; P<0.001 for P without vessels. Inter-observer agreement showed a bias of 1.8 ml for TR with vessels, 5.4 ml for P with vessels, and 4.6 ml for P without vessels. For the degree of manual correction, speed for completion and overall intuitiveness, scale values were 2.6±0.8, 2.4±0.5 and 2.CT-volumetry performed with P can predict accurately graft

  3. Coronary artery bypass grafting without cardiopulmonary bypass and without interruption of native coronary flow using a novel anastomosis site restraining device ("Octopus").

    Science.gov (United States)

    Borst, C; Jansen, E W; Tulleken, C A; Gründeman, P F; Mansvelt Beck, H J; van Dongen, J W; Hodde, K C; Bredée, J J

    1996-05-01

    This study assessed the feasibility of coronary artery bypass grafting on the beating heart without interruption of native coronary blood flow using a novel anastomosis site restraining device. Recently, an end-to-side bypass technique was described that does not require interruption of flow in the recipient artery. By means of a suction device ("Octopus"), in 31 pigs the epicardium was grasped and immobilized through an arm contraption fixed to the operating table. In the first 15 consecutive pigs (study I), the two-dimensional motion of an epicardial beacon was monitored. In 16 subsequent pigs (study II), an internal mammary artery was grafted under the microscope in two steps to a proximal coronary artery segment, without cardiopulmonary bypass. First, the internal mammary artery was sutured end-to-side to the outside of the coronary artery. Secondly, an orifice was punched in the partitioning coronary wall by an excimer laser catheter introduced through a temporary side-branch of the internal mammary artery. Study II: During 43 suction periods in four anastomosis areas, immobilization was achieved for 15 to 169 min (>30 h in total) in 13 open- and 9 closed-chest procedures without hemodynamic deterioration. The area circumscribed by the edges of the beacon trajectory (area in which the anastomosis is to be tracked) was reduced from 73.0 +/- 43.0 mm(2) (mean +/- SD) to 1.3 +/- 0.5 mm(2) (p<0.001) in the open-chest and to 0.2 +/- 0.2 mm(2) in the closed-chest procedure. At 6 weeks, no myocardial or coronary suction lesions were found. Study II: Nonocclusive anastomosis surgery required 25 +/- 3 min. No leakage, serious arrhythmias, graft closure or hemodynamic deterioration occurred during the procedure or for 2 h after ligating the coronary artery proximally. At 6 weeks, all seven grafts were patent. Coronary bypass on the beating heart without interruption of coronary flow is feasible. In both open- and in closed-chest procedures, the "Octopus" reduced

  4. Fast globally optimal segmentation of 3D prostate MRI with axial symmetry prior.

    Science.gov (United States)

    Qiu, Wu; Yuan, Jing; Ukwatta, Eranga; Sun, Yue; Rajchl, Martin; Fenster, Aaron

    2013-01-01

    We propose a novel global optimization approach to segmenting a given 3D prostate T2w magnetic resonance (MR) image, which enforces the inherent axial symmetry of the prostate shape and simultaneously performs a sequence of 2D axial slice-wise segmentations with a global 3D coherence prior. We show that the proposed challenging combinatorial optimization problem can be solved globally and exactly by means of convex relaxation. With this regard, we introduce a novel coupled continuous max-flow model, which is dual to the studied convex relaxed optimization formulation and leads to an efficient multiplier augmented algorithm based on the modern convex optimization theory. Moreover, the new continuous max-flow based algorithm was implemented on GPUs to achieve a substantial improvement in computation. Experimental results using public and in-house datasets demonstrate great advantages of the proposed method in terms of both accuracy and efficiency.

  5. Preliminary studies on 1-vinyl-2-pyrrolidone grafting onto cellulose by pre-irradiation method

    Energy Technology Data Exchange (ETDEWEB)

    Severich, Patrick; Dutra, Rodrigo da Costa; Kodama, Yasko, E-mail: ykodama@ipen.br, E-mail: patrick.severich@ipen.br, E-mail: rodrigo.dutra@ipen.br [Instituto de Pesquisas Energética s e Nucleares (IPEN-CNEN/SP), São Paulo, SP (Brazil)

    2017-07-01

    Cellulose is considered a renewable biopolymer most abundant in nature. Better functional surfaces can be Obtained by modifying cellulose. On the other hand, poly vinyl pyrrolidone, PVP, is a synthetic nontoxic, water-soluble polymer frequently used in an extensive variety of applications including several pharmaceutical applications. Grafting 1-vinyl-2-pyrrolidone, NVP, onto polymeric cellulose can be obtained by ionizing radiation. Ionizing radiation grafting can be affected by several factors as environment, solvent, monomer concentration, temperature of graft reaction. Grafting by ionizing radiation can be performed by three methods, pre-irradiation, oxidation by peroxide and simultaneous irradiation. In this study, it was used pre-irradiation method of cellulose. Paper filter without ash, NVP without purification was used in this study. Paper samples were exposed to electron beam from Dynamitron Accelerator with radiation absorbed dose of 25 kGy. Influence of NVP concentration, temperature of reaction after irradiation on degree of grafting (DG) was studied. Also, cellulose radicals of grafted paper samples was studied by electron paramagnetic resonance using a Bruker X-band ESR at room temperature just after heating reaction. Small decrease of cellulose radicals was observed with increasing reaction temperature. It was observed DG small increase with increasing concentration of monomer in solution of water ethanol 50-50 v:v and rising temperature of reaction. Further tests using simultaneous method of grafting of NVP in cellulose paper, in water:ethanol 75:25 v:v solution, induced by gamma irradiation were performed. It was observed homopolymerization forming PVP with increasing monomer concentration. (author)

  6. Preliminary studies on 1-vinyl-2-pyrrolidone grafting onto cellulose by pre-irradiation method

    International Nuclear Information System (INIS)

    Severich, Patrick; Dutra, Rodrigo da Costa; Kodama, Yasko

    2017-01-01

    Cellulose is considered a renewable biopolymer most abundant in nature. Better functional surfaces can be Obtained by modifying cellulose. On the other hand, poly vinyl pyrrolidone, PVP, is a synthetic nontoxic, water-soluble polymer frequently used in an extensive variety of applications including several pharmaceutical applications. Grafting 1-vinyl-2-pyrrolidone, NVP, onto polymeric cellulose can be obtained by ionizing radiation. Ionizing radiation grafting can be affected by several factors as environment, solvent, monomer concentration, temperature of graft reaction. Grafting by ionizing radiation can be performed by three methods, pre-irradiation, oxidation by peroxide and simultaneous irradiation. In this study, it was used pre-irradiation method of cellulose. Paper filter without ash, NVP without purification was used in this study. Paper samples were exposed to electron beam from Dynamitron Accelerator with radiation absorbed dose of 25 kGy. Influence of NVP concentration, temperature of reaction after irradiation on degree of grafting (DG) was studied. Also, cellulose radicals of grafted paper samples was studied by electron paramagnetic resonance using a Bruker X-band ESR at room temperature just after heating reaction. Small decrease of cellulose radicals was observed with increasing reaction temperature. It was observed DG small increase with increasing concentration of monomer in solution of water ethanol 50-50 v:v and rising temperature of reaction. Further tests using simultaneous method of grafting of NVP in cellulose paper, in water:ethanol 75:25 v:v solution, induced by gamma irradiation were performed. It was observed homopolymerization forming PVP with increasing monomer concentration. (author)

  7. Autologous fat graft and bone marrow-derived mesenchymal stem cells assisted fat graft for treatment of Parry-Romberg syndrome.

    Science.gov (United States)

    Jianhui, Zhao; Chenggang, Yi; Binglun, Lu; Yan, Han; Li, Yang; Xianjie, Ma; Yingjun, Su; Shuzhong, Guo

    2014-09-01

    Progressive facial hemiatrophy, also called Parry-Romberg syndrome (PRS), is characterized by slowly progressive atrophy of one side of the face and primarily involves the subcutaneous tissue and fat. The restoration of facial contour and symmetry in patients affected by PRS still remains a challenge clinically. Fat graft is a promising treatment but has some shortcomings, such as unpredictability and low rate of graft survival due to partial necrosis. To obviate these disadvantages, fat graft assisted by bone marrow-derived mesenchymal stem cells (BMSCs) was used to treat PRS patients and the outcome was evaluated in comparison with the conventional treatment by autologous fat graft. Autologous fat graft was harvested by tumescent liposuction. Bone marrow-derived mesenchymal stem cells were then isolated by human Lymphocytes Separation Medium through density gradient centrifugation. Twenty-six patients were treated with autologous fat graft only (group A), whereas 10 other patients were treated with BMSC-assisted fat graft (group B). The Coleman technique was applied in all fat graft injections. The follow-up period was 6 to 12 months in this study, In group A, satisfactory outcome judged by symmetrical appearances was obtained with 1 injection in 12 patients, 2 injections in 8 patients, and 3 injections in 4 patients. However, the result of 1 patient was not satisfactory and 1 patient was overcorrected. In group B, 10 patients obtained satisfactory outcomes and almost reached symmetry by 1 injection. No complications (infection, hematoma, or subcutaneous mass) were observed. The results suggest that BMSC-assisted fat graft is effective and safe for soft tissue augmentation and may be superior to conventional lipoinjection. Additional study is necessary to further evaluate the efficacy of this technique.

  8. Segmentation of 3D ultrasound computer tomography reflection images using edge detection and surface fitting

    Science.gov (United States)

    Hopp, T.; Zapf, M.; Ruiter, N. V.

    2014-03-01

    An essential processing step for comparison of Ultrasound Computer Tomography images to other modalities, as well as for the use in further image processing, is to segment the breast from the background. In this work we present a (semi-) automated 3D segmentation method which is based on the detection of the breast boundary in coronal slice images and a subsequent surface fitting. The method was evaluated using a software phantom and in-vivo data. The fully automatically processed phantom results showed that a segmentation of approx. 10% of the slices of a dataset is sufficient to recover the overall breast shape. Application to 16 in-vivo datasets was performed successfully using semi-automated processing, i.e. using a graphical user interface for manual corrections of the automated breast boundary detection. The processing time for the segmentation of an in-vivo dataset could be significantly reduced by a factor of four compared to a fully manual segmentation. Comparison to manually segmented images identified a smoother surface for the semi-automated segmentation with an average of 11% of differing voxels and an average surface deviation of 2mm. Limitations of the edge detection may be overcome by future updates of the KIT USCT system, allowing a fully-automated usage of our segmentation approach.

  9. Detection of acute synthetic vascular graft infection with IN-111 labeled leukocyte imaging

    International Nuclear Information System (INIS)

    Alazraki, N.; Dries, D.; Lawrence, P.; Murphy, K.; Kercher, J.; Datz, F.; Christian, P.; Taylor, A.

    1985-01-01

    Synthetic vascular graft infection is characterized by late diagnosis due to indolent and nonspecific symptoms. Reported data on accuracy of In-111 labeled leukocyte imaging to identify vascular graft infection is sparse and conflicting. The purpose of this animal study was to clarify the accuracy of detection of early graft infection using a mixed population of In-111 labeled leukocytes. Twelve mongrel dogs received dacron aortic interposition grafts. Seven grafts were contaminated at surgery by topical ATCC S. aureus, 10/sup 8/ organisms per ml. Six control animals received no graft contamination Mixed population In-111 homologous leukocyte labeling was performed followed by imaging at 24 and 48 hours following intravenous injection of 250 μCi In-111 leukocytes. Scans were done on Day 2 post-surgery. Infected dogs were sacrificed following Indium imaging; control dogs were rescanned at 3 weeks postop and sacrificed thereafter. Autopsy results were correlated with scans, yielding sensitivity 71%, specificity 100%, accuracy 85% for In-111 leukocyte imaging to detect early graft infection. False positive leukocyte imaging in the early postop period was not a problem. At autopsy all 5 dogs with infected grafts and positive scans had gross pus. The 2 dogs with false negative scans showed no gross pus at autopsy; cultures were positive for S. aureus in all 7 dogs. Scans at 2 days and 3 weeks post-surgery were true negatives in all 6 control dogs. These data suggest a high level of clinical reliability of leukocyte imaging for early graft infection detection

  10. Chromatographic study of the conformational behavior of graft copolymers with a broad distribution of grafting densities in dilute solutions in selective solvents for grafts

    Czech Academy of Sciences Publication Activity Database

    Netopilík, Miloš; Janata, Miroslav; Svitáková, Romana; Trhlíková, Olga; Berek, D.; Macova, E.; Limpouchová, Z.; Procházka, K.

    2016-01-01

    Roč. 39, č. 1 (2016), s. 50-58 ISSN 1082-6076 R&D Projects: GA ČR(CZ) GA13-02938S Grant - others:OPPK(XE) CZ.2.16/3.1.00/24504 Institutional support: RVO:61389013 Keywords : interaction chromatography * size exclusion chromatography * poly(4-methylstyrene)-graft-poly(2-vinylpyridine) Subject RIV: CD - Macromolecular Chemistry Impact factor: 0.697, year: 2016

  11. Osteosynthesis of ununited femoral neck fracture by internal fixation combined with iliac crest bone chips and muscle pedicle bone grafting

    Directory of Open Access Journals (Sweden)

    D D Baksi

    2016-01-01

    Full Text Available Background: Ununited femoral neck fracture is seen commonly in developing countries due to delayed presentation or failure of primary internal fixation. Such fractures, commonly present with partial or total absorption of femoral neck, osteonecrosis of femoral head in 8-30% cases with upward migration of trochanter posing problem for osteosynthesis, especially in younger individuals. Several techniques for treatment of such conditions are described like osteotomies or nonvascularied cortical or cancellous bone grafting provided varying degrees of success in terms of fracture union but unsatisfactory long term results occurred due to varying incidence of avascular necrosis (AVN of femoral head. Moreover, in presence of AVN of femoral head neither free fibular graft nor cancellous bone graft is satisfactory. The vascularied bone grafting by deep circumflex iliac artery based on iliac crest bone grafting, free vascularied fibular grafting and muscle pedicle periosteal grafting showed high incidence of success rate. Osteosynthesis is the preferred treatment of choice in ununited femoral neck fracture in younger individuals. Materials and Methods: Of the 293 patients operated during the period from June 1977 to June 2009, 42 were lost to followup. Seven patients with gluteus medius muscle pedicle bone grafting (MPBG were excluded. Thus, out of 244 patients, 208 (85.3% untreated nonunion and 36 (14.7% following failure of primary internal fixation were available for studies. Time interval between the date of injury and operation in untreated nonunion cases was mean 6.5 months and in failed internal fixation cases was mean 11.2 months. Ages of the patients varied from 16 to 55 years. Seventy patients had partial and 174 had subtotal absorption of the femoral neck. Evidence of avascular necrosis (AVN femoral head was found histologically in 135 (54.3% and radiologically in 48 (19.7% patients. The patients were operated by open reduction of fracture

  12. [Oral mucosa graft urethroplasty for complicated urethral strictures].

    Science.gov (United States)

    Horiguchi, Akio; Sumitomo, Makoto; Kanbara, Taiki; Tsujita, Yujiro; Yoshii, Takahiko; Yoshii, Hidehiko; Satoh, Akinori; Asakuma, Junichi; Ito, Keiichi; Hayakawa, Masamichi; Asano, Tomohiko

    2010-03-01

    We evaluated the efficacy and outcome of one-stage oral mucosa graft urethroplasty, which is currently the procedure of choice for treating lengthy and complicated urethral strictures not amenable to excision and primary end-to-end anastomosis. Seven patients 33 to 74 years old (mean age = 53.7) underwent one-stage oral mucosa graft urethroplasty for a stricture in either the bulbar urethra (four patients), penile urethra (two patients), or pan-anterior urethra (one patient). Three of the strictures were due to trauma, one was due to inflammation, and one was due to a failed hypospadia repair. The other two were iatrogenic. All patients had previously undergone either internal urethrotomy or repeated urethral dilation. Three patients received a tube graft, three received a ventral onlay, and one received a dorsal onlay. A free graft of oral mucosa was harvested from the inside of each patient's left cheek, and if necessary to obtain a sufficient length, the harvest was extended to include mucosa from the lower lip and the right cheek. The graft lengths ranged from 2.5 to 12 cm (mean = 4.6 cm). A urethral catheter was left in place for 3 weeks postoperatively. While no severe complications at the donor site were observed during follow-up periods ranging from 3 to 55 months (mean = 14 months), two patients who had received a tube graft developed distal anastomotic ring strictures that were managed by internal urethrotomy. The other five required no postoperative urological procedure even though one who had received a ventral onlay developed a penoscrotal fistula. Oral mucosa is an ideal urethral graft, and oral mucosa graft urethroplasty is an effective procedure for repairing complicated urethral strictures involving long portions of the urethra.

  13. Robust automatic high resolution segmentation of SOFC anode porosity in 3D

    DEFF Research Database (Denmark)

    Jørgensen, Peter Stanley; Bowen, Jacob R.

    2008-01-01

    Routine use of 3D characterization of SOFCs by focused ion beam (FIB) serial sectioning is generally restricted by the time consuming task of manually delineating structures within each image slice. We apply advanced image analysis algorithms to automatically segment the porosity phase of an SOFC...... anode in 3D. The technique is based on numerical approximations to partial differential equations to evolve a 3D surface to the desired phase boundary. Vector fields derived from the experimentally acquired data are used as the driving force. The automatic segmentation compared to manual delineation...... reveals and good correspondence and the two approaches are quantitatively compared. It is concluded that the. automatic approach is more robust, more reproduceable and orders of magnitude quicker than manual segmentation of SOFC anode porosity for subsequent quantitative 3D analysis. Lastly...

  14. Fusion Rates of Different Anterior Grafts in Thoracolumbar Fractures.

    Science.gov (United States)

    Antoni, Maxime; Charles, Yann Philippe; Walter, Axel; Schuller, Sébastien; Steib, Jean-Paul

    2015-11-01

    Retrospective CT analysis of anterior fusion in thoracolumbar trauma. The aim of this study was to compare fusion rates of different bone grafts and to analyze risk factors for pseudarthrosis. Interbody fusion is indicated in anterior column defects. Different grafts are used: autologous iliac crest, titanium mesh cages filled with cancellous bone, and autologous ribs. It is not clear which graft offers the most reliable fusion. Radiologic data of 116 patients (71 men, 45 women) operated for type A2, A3, B, or C fractures were analyzed. The average age was 44.6 years (range, 16-75 y) and follow-up was 2.7 years (range, 1-9 y). All patients were treated by posterior instrumentation followed by an anterior graft: 53 cases with iliac crest, 43 cases with mesh cages, and 20 with rib grafts. Fusion was evaluated on CT and classified into complete fusion, partial fusion, unipolar pseudarthrosis, and bipolar pseudarthrosis. Iliac crest fused in 66%, cages in 98%, and rib grafts in 90%. The fusion rate of cages filled with bone was significantly higher as the iliac graft fusion rate (P=0.002). The same was applied to rib grafts compared with iliac crest (P=0.041). Additional bone formation around the main graft, bridging both vertebral bodies, was observed in 31 of the 53 iliac crests grafts. Pseudarthrosis occurred more often in smokers (P=0.042). A relationship between fracture or instrumentation types, sex, age, BMI, and fusion could not be determined. Tricortical iliac crest grafts showed an unexpected high pseudarthrosis rate in thoracolumbar injuries. Their cortical bone is dense and their fusion surface is small. Rib grafts led to a better fusion when used in combination with the cancellous bone from the fractured vertebral body. Titanium mesh cages filled with cancellous bone led to the highest fusion rate and built a complete bony bridge between vertebral bodies. Smoking seemed to influence fusion. Case control study, Level III.

  15. Assessment of right liver graft perfusion effectiveness between one and two-catheter infusion methods.

    Science.gov (United States)

    Jung, Bo-Hyun; Hwang, Shin; Ha, Tae-Yong; Song, Gi-Won; Jung, Dong-Hwan; Kim, Ki-Hun; Ahn, Chul-Soo; Moon, Deok-Bog; Park, Gil-Chun; Kang, Sung-Hwa; Yoon, Young-In; Lee, Sung-Gyu

    2014-05-01

    Conventional graft perfusion method using one small-caliber catheter takes a relatively long time for right liver graft perfusion, thus some modification is needed. In this study, we intended to assess the effectiveness of right liver graft perfusion methods through comparison of different infusion catheters. The study consisted of two parts including one bench experiment to obtain data of hydraulic infusion and one clinical trial of 40 cases on graft perfusion with one- versus two-catheter infusion methods. These two graft infusion methods were compared in terms of the perfusion time and washing-out efficiency. At bench experiment, the infusion flow rate and infusion pressure were 3.3 ml/sec and 1.9 cmH20 in one blood transfusion catheter group, and 11.7 ml/sec and 3.1 cmH20 in single transurethral resection of prostate irrigation catheter group, and 6.6 ml/sec and 2.0 cmH20 in two blood transfusion catheters group, respectively. In clinical trial with 40 right liver grafts, two-catheter group had a shorter graft portal perfusion time for the first 2 L of histidine-tryptophan-ketoglutarate (HTK) solution than the conventional one-catheter group (375±25 seconds vs. 662±34 seconds; p=0.001) and a lower rate of incomplete blood washing-out after the initial 2 L portal perfusion (40% vs. 85%; p=0.03). The two-catheter infusion method appears to be more effective than the conventional one-catheter infusion method for right liver graft perfusion at the back table. Large size of right liver grafts seems to be its good indication.

  16. Beta irradiation inhibits neo-intimal formation in vein grafts

    International Nuclear Information System (INIS)

    Lang Xiaoou; Ji Shenquan; Zeng Ke; Li Jun; Liu Bingbing; Ma Wenfeng; Zhang Qiang

    2002-01-01

    Objective: The study was to evaluate the effect of beta irradiation on intimal proliferation response in vein grafts. Methods: An autogenous vein graft model was established in 40 rats by transplanting internal branch of jugular vein to carotid artery by end-to-end anastomosis. The vein was irradiated by 32 P before anastomosis. Four dose schedules were studied: (1) control graft (nonirradiated); (2) irradiated with 8 Gy; (3) 18 Gy; and (4) 36 Gy. The grafted veins were harvested at 2 weeks after the operation. IH (intimal hyperplasia) and SMC (smooth muscle cell) proliferation were histologically and immuno-histochemically observed and analyzed by a computer digitalising system. Results: In 18 Gy and 36 Gy-irradiated grafts compared with the control, there was a significant decrease in the average intimal thickness (P 0.05). Immunohistochemical analysis of PCNA indicated decrease of positive cells in both 18 Gy and 36 Gy groups compared with 8 Gy and the control group (P 0.05) groups, and there was also no significant difference between 8 Gy and the control group (P > 0.05). Conclusion: These preliminary results demonstrate that proper dose of beta irradiation in vein graft inhibits smooth muscle cells proliferation and neo-intimal hyperplasia in rat

  17. APPLICATION OF 3D MODELING IN 3D PRINTING FOR THE LOWER JAW RECONSTRUCTION

    Directory of Open Access Journals (Sweden)

    Yu. Yu. Dikov

    2015-01-01

    Full Text Available Aim of study: improvement of functional and aesthetic results of microsurgery reconstructions of the lower jaw due to the use of the methodology of 3D modeling and 3D printing. Application of this methodology has been demonstrated on the example of treatment of 4 patients with locally distributed tumors of the mouth cavity, who underwent excision of the tumor with simultaneous reconstruction of the lower jaw with revascularized fibular graft.Before, one patient has already undergo segmental resection of the lower jaw with the defect replacement with the avascular ileac graft and a reconstruction plate. Then, a relapse of the disease and lysis of the graft has developed with him. Modeling of the graft according to the shape of the lower jaw was performed by making osteotomies of the bone part of the graft using three-dimensional virtual models created by computed tomography data. Then these 3D models were printed with a 3D printer of plastic with the scale of 1:1 with the fused deposition modeling (FDM technology and were used during the surgery in the course of modeling of the graft. Sterilizing of the plastic model was performed in the formalin chamber.This methodology allowed more specific reconstruction of the resected fragment of the lower jaw and get better functional and aesthetic results and prepare patients to further dental rehabilitation. Advantages of this methodology are the possibility of simultaneous performance of stages of reconstruction and resection and shortening of the time of surgery.

  18. Grafting

    Energy Technology Data Exchange (ETDEWEB)

    Garnett, J L [New South Wales Univ., Kensington (Australia). School of Chemistry

    1979-01-01

    The unique value of ionizing radiation for the initiation of grafting to backbone polymers is discussed. The principles of the technique are briefly reviewed. The conditions under which free radicals and ions participate in these reactions are examined. Examples of representative grafting processes are considered to illustrate where the technique can be of potential commercial value to a wide range of industries. The general principles of these grafting reactions are shown to be applicable to radiation induced rapid cure technology such as is provided by electron beam processing facilities. Grafting reactions initiated by UV are also treated and shown to be of importance because of the many similarities in properties of the ionizing radiation and UV systems, also the rapid industrial exploitation of EB and sensitized UV processing technology. Possible future trends in radiation grafting are outlined.

  19. Use of Autologous Scleral Graft in Ahmed Glaucoma Valve Surgery.

    Science.gov (United States)

    Wolf, Alvit; Hod, Yair; Buckman, Gila; Stein, Nili; Geyer, Orna

    2016-04-01

    To compare the efficacy of an autoscleral free-flap graft versus an autoscleral rotational flap graft in Ahmed glaucoma valve (AGV) surgery. Medical records (2005 to 2012) of 51 consecutive patients (51 eyes) who underwent AGV surgery with the use of either an autoscleral free-flap graft or an autoscleral rotational flap graft to cover the external tube at the limbus were retrieved for review. The main outcome measure was the incidence of tube exposure associated with each surgical approach. Twenty-seven consecutive patients (27 eyes) received a free-flap graft and 24 consecutive patients (24 eyes) received a rotational flap graft. The mean follow-up time was 55.6 ± 18.3 months for the former and 24.2± 5 .0 months for the latter (P<0.0001). Two patients in the free-flap group (8.9%) developed tube exposure at 24 and 55 months postoperatively compared with none of the patients in the rotational flap group. Graft thinning without evidence of conjunctival erosion was observed in 15 patients (55%) in the free-flap group and in 7 patients (29.1%) in the rotational flap group. The use of an autoscleral rotational flap graft is an efficacious technique for primary tube patch grafting in routine AGV surgery, and yielded better results than an autoscleral free-flap graft. Its main advantages over donor graft material are availability and lower cost.

  20. AN ADAPTIVE APPROACH FOR SEGMENTATION OF 3D LASER POINT CLOUD

    Directory of Open Access Journals (Sweden)

    Z. Lari

    2012-09-01

    Full Text Available Automatic processing and object extraction from 3D laser point cloud is one of the major research topics in the field of photogrammetry. Segmentation is an essential step in the processing of laser point cloud, and the quality of extracted objects from laser data is highly dependent on the validity of the segmentation results. This paper presents a new approach for reliable and efficient segmentation of planar patches from a 3D laser point cloud. In this method, the neighbourhood of each point is firstly established using an adaptive cylinder while considering the local point density and surface trend. This neighbourhood definition has a major effect on the computational accuracy of the segmentation attributes. In order to efficiently cluster planar surfaces and prevent introducing ambiguities, the coordinates of the origin's projection on each point's best fitted plane are used as the clustering attributes. Then, an octree space partitioning method is utilized to detect and extract peaks from the attribute space. Each detected peak represents a specific cluster of points which are located on a distinct planar surface in the object space. Experimental results show the potential and feasibility of applying this method for segmentation of both airborne and terrestrial laser data.

  1. Ex Vivo Machine Perfusion in CTA with a Novel Oxygen Carrier System to Enhance Graft Preservation and Immunologic Outcomes

    Science.gov (United States)

    2015-10-01

    within 5 different segments of the VRAM grafts (e.g. skin, subcutaneous adipose tissue, muscle, microvasculature and large hilar vessels). This modified...Large vessels ( hilar structures of the VRAM graft) 5. Nerve tissue * p < 0.05 vs machine perfusion # p < 0.05 vs Baseline (BL) n=4 each...induced myelin damage Distribution Unlimited Page 27 d. axonal vacuolization e. axotomy 5. Large hilar vessels a. intraluminal thrombi b. loss of

  2. A Newly‑devised Technique for the Fixation of Mesh Skin Graft

    African Journals Online (AJOL)

    went skin graft using this technique. The ages ranged from. 9 months to 86 years (mean = 62.3 years). The skin defects included two burn ulcers, two decubitus, and 10 chronic leg ulcers. The size of the defects ranged from 20 cm2 to. 210 cm2. All grafts were accepted without complications. A 72-year-old man with a chronic ...

  3. Desalination by electrodialysis with ion-exchange membrane prepared by radiation-induced graft polymerization

    Energy Technology Data Exchange (ETDEWEB)

    Choi, Seong-Ho; Jeong, Young Han; Ryoo, Jae Jeong; Lee, Kwang-Pill [Department of Chemistry Graduate School, Kyungpook National University, Taegu (Korea)

    2000-07-01

    Ion-exchange membranes modified with triethylamine [-N(CH{sub 2}CH{sub 3}){sub 3}] and phosphoric acid (-PO{sub 3}H) groups were prepared by radiation-induced grafting of glycidyl methacrylate (GMA) onto polyolefin nonwavon fabric (PNF) and subsequent chemical modification of poly (GMA) graft chains. The physical and chemical properties of the GMA-grafted PNF and the PNF modified with ion-exchange groups were investigated by SEM and XPS. The ion-exchange capacities of the cation- and anion-exchange membrane were 0.20 and 1.24mmol/g, respectively. The content of cation- and anion exchange group increased with increasing grafting yield (d.g.=100%). Electrical resistance of PNF modified with TEA and -PO{sub 3}H group decreased with increasing ion-exchange group capacities. Application of the graft-type ion-exchange membranes as separators for electrodialysis enabled use to reduce the time required to achieve 85.5% desalination of the 0.5M NaCl solution. (author)

  4. Engineering anatomically shaped vascularized bone grafts with hASCs and 3D-printed PCL scaffolds.

    Science.gov (United States)

    Temple, Joshua P; Hutton, Daphne L; Hung, Ben P; Huri, Pinar Yilgor; Cook, Colin A; Kondragunta, Renu; Jia, Xiaofeng; Grayson, Warren L

    2014-12-01

    The treatment of large craniomaxillofacial bone defects is clinically challenging due to the limited availability of transplantable autologous bone grafts and the complex geometry of the bones. The ability to regenerate new bone tissues that faithfully replicate the anatomy would revolutionize treatment options. Advances in the field of bone tissue engineering over the past few decades offer promising new treatment alternatives using biocompatible scaffold materials and autologous cells. This approach combined with recent advances in three-dimensional (3D) printing technologies may soon allow the generation of large, bioartificial bone grafts with custom, patient-specific architecture. In this study, we use a custom-built 3D printer to develop anatomically shaped polycaprolactone (PCL) scaffolds with varying internal porosities. These scaffolds are assessed for their ability to support induction of human adipose-derived stem cells (hASCs) to form vasculature and bone, two essential components of functional bone tissue. The development of functional tissues is assessed in vitro and in vivo. Finally, we demonstrate the ability to print large mandibular and maxillary bone scaffolds that replicate fine details extracted from patient's computed tomography scans. The findings of this study illustrate the capabilities and potential of 3D printed scaffolds to be used for engineering autologous, anatomically shaped, vascularized bone grafts. © 2014 Wiley Periodicals, Inc.

  5. CT-based manual segmentation and evaluation of paranasal sinuses.

    Science.gov (United States)

    Pirner, S; Tingelhoff, K; Wagner, I; Westphal, R; Rilk, M; Wahl, F M; Bootz, F; Eichhorn, Klaus W G

    2009-04-01

    Manual segmentation of computed tomography (CT) datasets was performed for robot-assisted endoscope movement during functional endoscopic sinus surgery (FESS). Segmented 3D models are needed for the robots' workspace definition. A total of 50 preselected CT datasets were each segmented in 150-200 coronal slices with 24 landmarks being set. Three different colors for segmentation represent diverse risk areas. Extension and volumetric measurements were performed. Three-dimensional reconstruction was generated after segmentation. Manual segmentation took 8-10 h for each CT dataset. The mean volumes were: right maxillary sinus 17.4 cm(3), left side 17.9 cm(3), right frontal sinus 4.2 cm(3), left side 4.0 cm(3), total frontal sinuses 7.9 cm(3), sphenoid sinus right side 5.3 cm(3), left side 5.5 cm(3), total sphenoid sinus volume 11.2 cm(3). Our manually segmented 3D-models present the patient's individual anatomy with a special focus on structures in danger according to the diverse colored risk areas. For safe robot assistance, the high-accuracy models represent an average of the population for anatomical variations, extension and volumetric measurements. They can be used as a database for automatic model-based segmentation. None of the segmentation methods so far described provide risk segmentation. The robot's maximum distance to the segmented border can be adjusted according to the differently colored areas.

  6. Quantitation of mandibular ramus volume as a source of bone grafting.

    Science.gov (United States)

    Verdugo, Fernando; Simonian, Krikor; Smith McDonald, Roberto; Nowzari, Hessam

    2009-10-01

    When alveolar atrophy impairs dental implant placement, ridge augmentation using mandibular ramus graft may be considered. In live patients, however, an accurate calculation of the amount of bone that can be safely harvested from the ramus has not been reported. The use of a software program to perform these calculations can aid in preventing surgical complications. The aim of the present study was to intra-surgically quantify the volume of the ramus bone graft that can be safely harvested in live patients, and compare it to presurgical computerized tomographic calculations. The AutoCAD software program quantified ramus bone graft in 40 consecutive patients from computerized tomographies. Direct intra-surgical measurements were recorded thereafter and compared to software data (n = 10). In these 10 patients, the bone volume was also measured at the recipient sites 6 months post-sinus augmentation. The mandibular second and third molar areas provided the thickest cortical graft averaging 2.8 +/- 0.6 mm. The thinnest bone was immediately posterior to the third molar (1.9 +/- 0.3 mm). The volume of ramus bone graft measured by AutoCAD averaged 0.8 mL (standard deviation [SD] 0.2 mL, range: 0.4-1.2 mL). The volume of bone graft measured intra-surgically averaged 2.5 mL (SD 0.4 mL, range: 1.8-3.0 mL). The difference between the two measurement methods was significant (p AutoCAD software program did not overestimate the volume of bone that can be safely harvested from the mandibular ramus.

  7. Mesoscopic multiphase structures and the interfaces of block and graft copolymers in bulk

    International Nuclear Information System (INIS)

    Matsushita, Yushu

    1996-01-01

    Microphase-separated structures of copolymers with various architectures and their polymer/polymer interfaces were studied. They are SP diblock, PSP triblock, and SPP graft copolymers, where S and P denote polystyrene and poly(2-vinylpyridine), respectively. Morphological observations were carried out by means of transmission electron microscopy and small-angle X-ray scattering. Chain dimensions of component polymers were measured by small-angle neutron scattering and microphase-separated interfaces were observed by neutron reflectivity measurements using deuterium-labeled samples. It was clarified that morphological phase transitions among thermodynamically equilibrium structures for SP diblock and PSP triblock copolymers occur at almost the same compositions; however, those of SPP graft copolymers tend to occur at higher volume fraction of polystyrene, φ s , than those for block copolymers. As for alternating lamellar structures it turned out to be clear that lamellar domain spacings, D's, were scaled as the 2/3 power of the molecular weight of polymers irrespective of their architectures. S block chains of SP diblock and PSP triblock copolymers in lamellar structures were both confirmed to be deformed toward the direction perpendicular to the lamellar interfaces, but it revealed that their volumes were preserved. Further, S/P interfacial thicknesses of SP and PSP were essentially the same to each other and the values defined as the FWHM of the error functions which express the segment density distributions of the interfaces were determined to be about 4 nm. (author)

  8. Vascularized fibular graft in infected tibial bone loss

    Directory of Open Access Journals (Sweden)

    C Cheriyan Kovoor

    2011-01-01

    union occurred in all patients in a mean time of 3.3 months, at both ends. At a minimum followup of 24 months the mean hypertrophy noted was 63.6% (30 - 136% in the vascularized fibular graft. Ten stress fractures occurred in seven patients. The mean duration of the occurrence of a stress fracture in the graft was 11.1 months (2.5 - 18 months postoperatively. The highest incidence of stress fractures was when the graft hypertrophy was less than 20%. The incidence of stress fractures reduced significantly after the graft hypertrophy exceeded 20%. Conclusion : In most cases hypertrophy of the vascularized fibular graft occurs in response to mechanical loading by protected weight bearing, and the amount of hypertrophy is variable. The presence or absence of an intact fibula has no bearing on the hypertrophy or incidence of stress fracture. The length of the fibular graft has no bearing on the hypertrophy or stress fracture.

  9. Semi-automatic segmentation of myocardium at risk in T2-weighted cardiovascular magnetic resonance.

    Science.gov (United States)

    Sjögren, Jane; Ubachs, Joey F A; Engblom, Henrik; Carlsson, Marcus; Arheden, Håkan; Heiberg, Einar

    2012-01-31

    T2-weighted cardiovascular magnetic resonance (CMR) has been shown to be a promising technique for determination of ischemic myocardium, referred to as myocardium at risk (MaR), after an acute coronary event. Quantification of MaR in T2-weighted CMR has been proposed to be performed by manual delineation or the threshold methods of two standard deviations from remote (2SD), full width half maximum intensity (FWHM) or Otsu. However, manual delineation is subjective and threshold methods have inherent limitations related to threshold definition and lack of a priori information about cardiac anatomy and physiology. Therefore, the aim of this study was to develop an automatic segmentation algorithm for quantification of MaR using anatomical a priori information. Forty-seven patients with first-time acute ST-elevation myocardial infarction underwent T2-weighted CMR within 1 week after admission. Endocardial and epicardial borders of the left ventricle, as well as the hyper enhanced MaR regions were manually delineated by experienced observers and used as reference method. A new automatic segmentation algorithm, called Segment MaR, defines the MaR region as the continuous region most probable of being MaR, by estimating the intensities of normal myocardium and MaR with an expectation maximization algorithm and restricting the MaR region by an a priori model of the maximal extent for the user defined culprit artery. The segmentation by Segment MaR was compared against inter observer variability of manual delineation and the threshold methods of 2SD, FWHM and Otsu. MaR was 32.9 ± 10.9% of left ventricular mass (LVM) when assessed by the reference observer and 31.0 ± 8.8% of LVM assessed by Segment MaR. The bias and correlation was, -1.9 ± 6.4% of LVM, R = 0.81 (p Segment MaR, -2.3 ± 4.9%, R = 0.91 (p Segment MaR and manually assessed MaR in T2-weighted CMR. Thus, the proposed algorithm seems to be a promising, objective method for standardized MaR quantification in T2

  10. Hepatic vessel segmentation for 3D planning of liver surgery experimental evaluation of a new fully automatic algorithm.

    Science.gov (United States)

    Conversano, Francesco; Franchini, Roberto; Demitri, Christian; Massoptier, Laurent; Montagna, Francesco; Maffezzoli, Alfonso; Malvasi, Antonio; Casciaro, Sergio

    2011-04-01

    The aim of this study was to identify the optimal parameter configuration of a new algorithm for fully automatic segmentation of hepatic vessels, evaluating its accuracy in view of its use in a computer system for three-dimensional (3D) planning of liver surgery. A phantom reproduction of a human liver with vessels up to the fourth subsegment order, corresponding to a minimum diameter of 0.2 mm, was realized through stereolithography, exploiting a 3D model derived from a real human computed tomographic data set. Algorithm parameter configuration was experimentally optimized, and the maximum achievable segmentation accuracy was quantified for both single two-dimensional slices and 3D reconstruction of the vessel network, through an analytic comparison of the automatic segmentation performed on contrast-enhanced computed tomographic phantom images with actual model features. The optimal algorithm configuration resulted in a vessel detection sensitivity of 100% for vessels > 1 mm in diameter, 50% in the range 0.5 to 1 mm, and 14% in the range 0.2 to 0.5 mm. An average area overlap of 94.9% was obtained between automatically and manually segmented vessel sections, with an average difference of 0.06 mm(2). The average values of corresponding false-positive and false-negative ratios were 7.7% and 2.3%, respectively. A robust and accurate algorithm for automatic extraction of the hepatic vessel tree from contrast-enhanced computed tomographic volume images was proposed and experimentally assessed on a liver model, showing unprecedented sensitivity in vessel delineation. This automatic segmentation algorithm is promising for supporting liver surgery planning and for guiding intraoperative resections. Copyright © 2011 AUR. Published by Elsevier Inc. All rights reserved.

  11. Synthesis of Fuel Cell Membrane: Copolymerization of Styrene on ETFE Film by Grafted pre-Irradiation

    Directory of Open Access Journals (Sweden)

    Yohan Yohan

    2010-10-01

    Full Text Available Preirradiation Grafting styrene monomer on ETFE  film has been prepared. Research has been  performed by γ-ray radiation at various total dose from 2.5 - 12.5 kGy and various dose rate from 1.3 - 1.9 kGy/hour. Irradiated copolymer is then grafted by styrene monomer in various solvent: ethanol, 2-propanol, and toluene, various concentration from 20 - 70% volume, various temperature from 50 - 90oC, and various grafting time from 2 - 12 hours. The results showed that percent of grafting is increase with increase of total dose and decrease of  rate dose. The optimum experiment conditions are obtained at total dose 10 kGy, dose rate 1,9 kGy/hour, 2-propanol solvent, 40% volume styrene, 4 hours grafting time, and 70oC grafting temperature.

  12. Automated bone segmentation from large field of view 3D MR images of the hip joint

    International Nuclear Information System (INIS)

    Xia, Ying; Fripp, Jurgen; Chandra, Shekhar S; Schwarz, Raphael; Engstrom, Craig; Crozier, Stuart

    2013-01-01

    Accurate bone segmentation in the hip joint region from magnetic resonance (MR) images can provide quantitative data for examining pathoanatomical conditions such as femoroacetabular impingement through to varying stages of osteoarthritis to monitor bone and associated cartilage morphometry. We evaluate two state-of-the-art methods (multi-atlas and active shape model (ASM) approaches) on bilateral MR images for automatic 3D bone segmentation in the hip region (proximal femur and innominate bone). Bilateral MR images of the hip joints were acquired at 3T from 30 volunteers. Image sequences included water-excitation dual echo stead state (FOV 38.6 × 24.1 cm, matrix 576 × 360, thickness 0.61 mm) in all subjects and multi-echo data image combination (FOV 37.6 × 23.5 cm, matrix 576 × 360, thickness 0.70 mm) for a subset of eight subjects. Following manual segmentation of femoral (head–neck, proximal-shaft) and innominate (ilium+ischium+pubis) bone, automated bone segmentation proceeded via two approaches: (1) multi-atlas segmentation incorporating non-rigid registration and (2) an advanced ASM-based scheme. Mean inter- and intra-rater reliability Dice's similarity coefficients (DSC) for manual segmentation of femoral and innominate bone were (0.970, 0.963) and (0.971, 0.965). Compared with manual data, mean DSC values for femoral and innominate bone volumes using automated multi-atlas and ASM-based methods were (0.950, 0.922) and (0.946, 0.917), respectively. Both approaches delivered accurate (high DSC values) segmentation results; notably, ASM data were generated in substantially less computational time (12 min versus 10 h). Both automated algorithms provided accurate 3D bone volumetric descriptions for MR-based measures in the hip region. The highly computational efficient ASM-based approach is more likely suitable for future clinical applications such as extracting bone–cartilage interfaces for potential cartilage segmentation. (paper)

  13. Automated bone segmentation from large field of view 3D MR images of the hip joint

    Science.gov (United States)

    Xia, Ying; Fripp, Jurgen; Chandra, Shekhar S.; Schwarz, Raphael; Engstrom, Craig; Crozier, Stuart

    2013-10-01

    Accurate bone segmentation in the hip joint region from magnetic resonance (MR) images can provide quantitative data for examining pathoanatomical conditions such as femoroacetabular impingement through to varying stages of osteoarthritis to monitor bone and associated cartilage morphometry. We evaluate two state-of-the-art methods (multi-atlas and active shape model (ASM) approaches) on bilateral MR images for automatic 3D bone segmentation in the hip region (proximal femur and innominate bone). Bilateral MR images of the hip joints were acquired at 3T from 30 volunteers. Image sequences included water-excitation dual echo stead state (FOV 38.6 × 24.1 cm, matrix 576 × 360, thickness 0.61 mm) in all subjects and multi-echo data image combination (FOV 37.6 × 23.5 cm, matrix 576 × 360, thickness 0.70 mm) for a subset of eight subjects. Following manual segmentation of femoral (head-neck, proximal-shaft) and innominate (ilium+ischium+pubis) bone, automated bone segmentation proceeded via two approaches: (1) multi-atlas segmentation incorporating non-rigid registration and (2) an advanced ASM-based scheme. Mean inter- and intra-rater reliability Dice's similarity coefficients (DSC) for manual segmentation of femoral and innominate bone were (0.970, 0.963) and (0.971, 0.965). Compared with manual data, mean DSC values for femoral and innominate bone volumes using automated multi-atlas and ASM-based methods were (0.950, 0.922) and (0.946, 0.917), respectively. Both approaches delivered accurate (high DSC values) segmentation results; notably, ASM data were generated in substantially less computational time (12 min versus 10 h). Both automated algorithms provided accurate 3D bone volumetric descriptions for MR-based measures in the hip region. The highly computational efficient ASM-based approach is more likely suitable for future clinical applications such as extracting bone-cartilage interfaces for potential cartilage segmentation.

  14. Renographic indices for evaluation of changes in graft function

    Energy Technology Data Exchange (ETDEWEB)

    El-Maghraby, T.A.F.; Eck-Smit, B.L.F. van; Pauwels, E.K.J. [Division of Nuclear Medicine, Department of Radiology, Leiden University Medical Centre, Leiden (Netherlands); Fijter, J.W. de [Department of Nephrology, Leiden University Medical Centre, Leiden (Netherlands); Zwinderman, A.H. [Department of Medical Statistics, Leiden University Medical Centre, Leiden (Netherlands); El-Haddad, S.I. [Department of Oncology and Nuclear Medicine, Cairo University (Egypt)

    1998-11-01

    Radionuclide renal diagnostic studies play an important role in assessing renal allograft function, especially in the early post-transplant period. In the past two decades various quantitative parameters have been derived from the radionuclide renogram to evaluate changes in perfusion and/or function of the kidney allograft. In this review article we discuss the quantitative parameters that have been used to assess graft condition, with emphasis on the early postoperative period. These quantitative methods are divided into parameters used for assessing renal graft perfusion and parameters used for evaluating parenchymal function. The blood flow in renal transplants can be quantified (a) by measuring the rate of activity appearance in the kidney graft, (b) by calculating the ratio of the integral activity under the transplanted kidney and arterial curves and (c) by calculating the renal vascular transit time. In this article we review a number of parenchymal uptake and excretion indices, such as the accumulation index, the graft uptake capacity at 2 and 10 min, the excretion index and the elimination index. The literature on these parameters shows that they have some practical disadvantages. In addition, values suffer from significant overlap when various graft pathologies coexist. A retrospective study was designed in our institution to evaluate the clinical usefulness of some of the frequently used previously published methods in which the graft function is quantitatively assessed in the early post-transplant period. The quantitative parameters studied which were reasonably reproducible in our hands included: global perfusion index (GPI), cortical perfusion index (CPI), vascular transit time, and the parenchymal parameters uptake capacity at 2 min (UC{sub 2}) and elimination index (K{sub 3/20}). The patient population in this study consisted of 43 patients with 157 technetium-99m mercaptylacetyltriglycine renograms. The perfusion indices GPI and CPI did not allow

  15. Dialysis grafts arterial plug: Retrieval using the tulip sheath device in vitro

    International Nuclear Information System (INIS)

    Sharafuddin, Melhem J.; Titus, Jack L.; Gu Xiaoping; Hunter, David W.; Amplatz, Kurt

    1997-01-01

    The 'arterial plug' is a resistant thrombus that frequently persists at the arterial anastomosis of clotted hemodialysis grafts following thrombolytic therapy. We studied the physical and morphological characteristics of the plug and determined the feasibility of transcatheter removal in vitro using the tulip compression thrombectomy system. Sixteen thrombus plugs were recovered during surgical thrombectomy of clotted human dialysis grafts. The physical and gross physical characteristics of all plugs were analyzed. Eight specimens were evaluated microscopically. Transcatheter compression thrombectomy of eight plugs was attempted in vitro. Each plug was embedded in a polyvinyl tube filled with newly clotted blood and connected to a flow circuit. First, balloon-assisted aspiration thrombectomy (BAT) of soft thrombus was performed, while sparing the distal-most segment containing the plug. The tulip sheath was then introduced facing the 'arterial end' of the tube. The thrombus segment containing the plug was pulled back into the tulip mesh using either a 3 Fr Fogarty balloon catheter or a self-expanding rake. The tulip was closed to compress and remove the trapped plug. Near-complete thrombectomy of soft clot was achieved in all tested tubes. Compression and retrieval of the entire arterial plug was successful in all except one, where only partial compression of the plug occurred, presumably due to fibrotic changes. No fragmentation or embolization occurred in the remaining procedures. Spongy consistency was noted in 94% of the specimens. Microscopic evaluation showed organized layered thrombus with compaction in five plugs. Transcatheter removal of a thrombus plug is feasible in vitro using the tulip compression-thrombectomy system

  16. A wavelet-based Bayesian framework for 3D object segmentation in microscopy

    Science.gov (United States)

    Pan, Kangyu; Corrigan, David; Hillebrand, Jens; Ramaswami, Mani; Kokaram, Anil

    2012-03-01

    In confocal microscopy, target objects are labeled with fluorescent markers in the living specimen, and usually appear with irregular brightness in the observed images. Also, due to the existence of out-of-focus objects in the image, the segmentation of 3-D objects in the stack of image slices captured at different depth levels of the specimen is still heavily relied on manual analysis. In this paper, a novel Bayesian model is proposed for segmenting 3-D synaptic objects from given image stack. In order to solve the irregular brightness and out-offocus problems, the segmentation model employs a likelihood using the luminance-invariant 'wavelet features' of image objects in the dual-tree complex wavelet domain as well as a likelihood based on the vertical intensity profile of the image stack in 3-D. Furthermore, a smoothness 'frame' prior based on the a priori knowledge of the connections of the synapses is introduced to the model for enhancing the connectivity of the synapses. As a result, our model can successfully segment the in-focus target synaptic object from a 3D image stack with irregular brightness.

  17. Development of Novel Absorbents and Membranes by Radiation-Induced Grafting for Selective Purposes

    Energy Technology Data Exchange (ETDEWEB)

    Hegazy, E A; Abdel-Rehim, H; Hegazy, D; Ali, A A; Kamal, H; Sayed, A [National Center for Radiation Research and Technology, Atomic Energy Egypt, P.O.Box 29, Nasr City, Cairo (Egypt)

    2012-09-15

    The direct radiation grafting technique was used to graft glycidyl methacrylate (GMA) monomer containing epoxy ring, onto polypropylene fibres. The ring opening of the epoxy ring in GMA by different amino groups was studied to introduce various chelating agents. Some properties of grafted fibres were studied and the possibility of its practical use for water treatment from iron and manganese metals was investigated. The radiation initiated grafting of acrylic acid (AAc) or acrylamide (AAm) monomers onto poly(vinyl alcohol) (PVA), a 2-acrylamide-2-methyl propane sulfonic acid (AMPS) polymer was studied. Cationic/anionic membranes were also prepared by radiation-induced grafting of styrene/methacrylic acid (Sty/MAA) binary monomers onto LDPE films. To impart reactive cationic/anionic characters in the grafted membranes, sulfonation and alkaline treatments for styrene and carboxylic acid groups, respectively, were carried out. The possibility of their applications in the selective removal of some heavy metals was studied. The prepared grafted materials had a great ability to recover the metal ions such as: Ni{sup 2+}, Co{sup 2+}, Cu{sup 2+}, Cd{sup 2+}, Mg{sup 2+}, Zn{sup 2+}, Mn{sup 2+} and Cr{sup 3+} from their solutions. It was found that AMPS content in the grafted copolymers is the main parameter for the selectivity of the copolymer towards metal ions. The higher the AMPS content the higher the selectivity towards Co and Ni ions. In case of LDPE-g-P(STY/MAA), the sulfonation and alkaline treatments are the most effective methods to influence metal absorption and swelling behaviour of the prepared membranes. Graft composition, dose and pH have also a great influence on the membrane characteristics and applicability in wastewater treatments from heavy and toxic metals. Results revealed that the prepared grafted materials with different functionalized groups are promising as ion selective membranes and could be used for wastewater treatment. (author)

  18. Prolonged Delayed Graft Function Is Associated with Inferior Patient and Kidney Allograft Survivals.

    Directory of Open Access Journals (Sweden)

    Tainá Veras de Sandes-Freitas

    Full Text Available It is unclear if there is an association between the duration of delayed graft function (DGF and kidney transplant (KT outcomes. This study investigated the impact of prolonged DGF on patient and graft survivals, and renal function one year after KT. This single center retrospective analysis included all deceased donor KT performed between Jan/1998 and Dec/2008 (n = 1412. Patients were grouped in quartiles according to duration of DGF (1-5, 6-10, 11-15, and >15 days, designated as prolonged DGF. The overall incidence of DGF was 54.2%. Prolonged DGF was associated with retransplantation (OR 2.110, CI95% 1.064-4.184,p = 0.033 and more than 3 HLA mismatches (OR 1.819, CI95% 1.117-2.962,p = 0.016. The incidence of acute rejection was higher in patients with DGF compared with those without DGF (36.2% vs. 12.2%, p<0.001. Compared to patients without DGF, DGF(1-5, DGF(6-10, and DGF(11-15, patients with prolonged DGF showed inferior one year patient survival (95.2% vs. 95.4% vs. 95.5% vs. 93.4% vs. 88.86%, p = 0.003, graft survival (91% vs. 91.4% vs. 92% vs. 88.7% vs. 70.5%, p<0.001, death-censored graft survival (95.7% vs. 95.4% vs. 96.4% vs. 94% vs. 79.3%, p<0.001, and creatinine clearance (58.0±24.6 vs. 55.8±22.2 vs. 53.8±24.1 vs. 53.0±27.2 vs. 36.8±27.0 mL/min, p<0.001, respectively. Multivariable analysis showed that prolonged DGF was an independent risk factor for graft loss (OR 3.876, CI95% 2.270-6.618, p<0.001, death censored graft loss (OR 4.103, CI95% 2.055-8.193, p<0.001, and death (OR 3.065, CI95% 1.536-6.117, p = 0.001. Prolonged DGF, determined by retransplantation and higher HLA mismatches, was associated with inferior renal function, and patient and graft survivals at one year.

  19. Segmented block copolymers with monodisperse aramide end-segments

    NARCIS (Netherlands)

    Araichimani, A.; Gaymans, R.J.

    2008-01-01

    Segmented block copolymers were synthesized using monodisperse diaramide (TT) as hard segments and PTMO with a molecular weight of 2 900 g · mol-1 as soft segments. The aramide: PTMO segment ratio was increased from 1:1 to 2:1 thereby changing the structure from a high molecular weight multi-block

  20. Carboxy terminated rubber based on natural rubber grafted with acid anhydrides and its adhesion properties

    International Nuclear Information System (INIS)

    Klinpituksa, P; Kongkalai, P; Kaesaman, A

    2014-01-01

    The chemical modification of natural rubber by grafting of various polar functional molecules is an essential method, improving the versatility of rubber in applications. This research investigated the preparation of natural rubber-graft-citraconic anhydride (NR-g-CCA), natural rubber-graft-itaconic anhydride (NR-g-ICA), and natural rubber-graft-maleic anhydride (NR-g-MA), with the anhydrides grafted to natural rubber in toluene using benzoyl peroxide as an initiator. Variations of monomer content, initiator content, temperature and reaction time of the grafting copolymerization were investigated. The maximum degrees of grafting were 1.06% for NR-g-CCA, 4.66% for NR-g-ICA, and 5.03% for NR-g-MA, reached using 10 phr citraconic anhydride, 10 phr of itaconic anhydride, or 8 phr of maleic anhydride, 3 phr benzoyl peroxide, at 85, 80 and 80°C for 2, 2 and 3 hrs, respectively. Solvent-based wood adhesives were formulated from these copolymers with various contents of wood resin in the range 10-40 phr. The maximal 289 N/in cleavage peel and 245.7 KPa shear strength for NR-g-MA (5.03% grafting) were obtained at 40 phr wood resin

  1. Quantitation of mandibular symphysis volume as a source of bone grafting.

    Science.gov (United States)

    Verdugo, Fernando; Simonian, Krikor; Smith McDonald, Roberto; Nowzari, Hessam

    2010-06-01

    Autogenous intramembranous bone graft present several advantages such as minimal resorption and high concentration of bone morphogenetic proteins. A method for measuring the amount of bone that can be harvested from the symphysis area has not been reported in real patients. The aim of the present study was to intrasurgically quantitate the volume of the symphysis bone graft that can be safely harvested in live patients and compare it with AutoCAD (version 16.0, Autodesk, Inc., San Rafael, CA, USA) tomographic calculations. AutoCAD software program quantitated symphysis bone graft in 40 patients using computerized tomographies. Direct intrasurgical measurements were recorded thereafter and compared with AutoCAD data. The bone volume was measured at the recipient sites of a subgroup of 10 patients, 6 months post sinus augmentation. The volume of bone graft measured by AutoCAD averaged 1.4 mL (SD 0.6 mL, range: 0.5-2.7 mL). The volume of bone graft measured intrasurgically averaged 2.3 mL (SD 0.4 mL, range 1.7-2.8 mL). The statistical difference between the two measurement methods was significant. The bone volume measured at the recipient sites 6 months post sinus augmentation averaged 1.9 mL (SD 0.3 mL, range 1.3-2.6 mL) with a mean loss of 0.4 mL. AutoCAD did not overestimate the volume of bone that can be safely harvested from the mandibular symphysis. The use of the design software program may improve surgical treatment planning prior to sinus augmentation.

  2. Ab interno management of blocked Ahmed valve in the posterior segment.

    Science.gov (United States)

    Odrich, Steven; Wald, Kenneth; Sperber, Laurence

    2013-01-01

    To report a case of late failure of a posterior segment placed Ahmed valve in a uveitic eye with a corneal graft and a minimally invasive, ab interno approach in restoring valve function, pressure control, and preservation of vision. Case report. A 25 gauge trans-conjunctival 3-port pars plana vitrectomy was performed to inspect and clean the ostium of the Ahmed valve of any vitreous debris. The Ahmed valve was not disturbed externally and conjunctival dissection was not performed. A 27-gauge blunt cannula was introduced through the vitrector site and used to cannulate the tube and flush it with balanced salt solution. A bleb was immediately re-established and all instruments were removed requiring no sutures. Intraocular pressure returned to target levels and a filtration bleb was re-established. Corneal graft clarity was restored with resolution of preoperative microcystic edema. Postoperative inflammation was minimal and vision was restored. A nonfunctioning tube shunt residing in the vitreous cavity may be revised ab interno without disturbing the shunt placement or the conjunctiva under which it resides to re-establish filtration.

  3. Poly(vinyl chloride)-g-poly(2-(dimethylamino)ethyl methacrylate) graft copolymers templated synthesis of mesoporous TiO{sub 2} thin films for dye-sensitized solar cells

    Energy Technology Data Exchange (ETDEWEB)

    Patel, Rajkumar; Ahn, Sung Hoon; Seo, Jin Ah; Kim, Sang Jin; Kim, Jong Hak, E-mail: jonghak@yonsei.ac.kr [Yonsei University, Department of Chemical and Biomolecular Engineering (Korea, Republic of)

    2012-07-15

    A poly(vinyl chloride) (PVC) main chain was grafted with poly(2-(dimethylamino)ethyl methacrylate) (PDMAEMA) containing a quaternary amine group using atom transfer radical polymerization. The successful synthesis of a PVC-g-PDMAEMA graft copolymer was confirmed by Fourier transform infrared, nuclear magnetic resonance, thermogravimetric analysis, and transmission electron microscopy. The PVC-g-PDMAEMA graft copolymer was used as a structure-directing agent (SDA) for the fabrication of a mesoporous thin film containing a titanium dioxide (TiO{sub 2}) layer. To control the porosity of the resultant inorganic layer, the ratio of SDA to TTIP as well as the concentration of the sol-gel was varied. The structure and porosity of the mesoporous film were characterized by XRD and SEM analysis. The mesoporous TiO{sub 2} film fabricated on the FTO surface was used as a photoanode for the dye-sensitized solar cell (DSSC). DSSC performance was the greatest when using TiO{sub 2} film with a higher porosity and lower interfacial resistance. The highest energy conversion efficiency reached 3.2 % at 100 mW/cm{sup 2}, which was one of the highest reported values for a quasi-solid-state DSSC with 600-nm-thick TiO{sub 2} film.

  4. Fast CSF MRI for brain segmentation; Cross-validation by comparison with 3D T1-based brain segmentation methods

    DEFF Research Database (Denmark)

    van der Kleij, Lisa A.; de Bresser, Jeroen; Hendrikse, Jeroen

    2018-01-01

    ObjectiveIn previous work we have developed a fast sequence that focusses on cerebrospinal fluid (CSF) based on the long T-2 of CSF. By processing the data obtained with this CSF MRI sequence, brain parenchymal volume (BPV) and intracranial volume (ICV) can be automatically obtained. The aim...... of this study was to assess the precision of the BPV and ICV measurements of the CSF MRI sequence and to validate the CSF MRI sequence by comparison with 3D T-1-based brain segmentation methods.Materials and methodsTen healthy volunteers (2 females; median age 28 years) were scanned (3T MRI) twice......cc) and CSF HR (5 +/- 5/4 +/- 2cc) were comparable to FSL HR (9 +/- 11/19 +/- 23cc), FSL LR (7 +/- 4,6 +/- 5cc),FreeSurfer HR (5 +/- 3/14 +/- 8cc), FreeSurfer LR (9 +/- 8,12 +/- 10cc), and SPM HR (5 +/- 3/4 +/- 7cc), and SPM LR (5 +/- 4,5 +/- 3cc). The correlation between the measured volumes...

  5. Rule-based model of vein graft remodeling.

    Directory of Open Access Journals (Sweden)

    Minki Hwang

    Full Text Available When vein segments are implanted into the arterial system for use in arterial bypass grafting, adaptation to the higher pressure and flow of the arterial system is accomplished thorough wall thickening and expansion. These early remodeling events have been found to be closely coupled to the local hemodynamic forces, such as shear stress and wall tension, and are believed to be the foundation for later vein graft failure. To further our mechanistic understanding of the cellular and extracellular interactions that lead to global changes in tissue architecture, a rule-based modeling method is developed through the application of basic rules of behaviors for these molecular and cellular activities. In the current method, smooth muscle cell (SMC, extracellular matrix (ECM, and monocytes are selected as the three components that occupy the elements of a grid system that comprise the developing vein graft intima. The probabilities of the cellular behaviors are developed based on data extracted from in vivo experiments. At each time step, the various probabilities are computed and applied to the SMC and ECM elements to determine their next physical state and behavior. One- and two-dimensional models are developed to test and validate the computational approach. The importance of monocyte infiltration, and the associated effect in augmenting extracellular matrix deposition, was evaluated and found to be an important component in model development. Final model validation is performed using an independent set of experiments, where model predictions of intimal growth are evaluated against experimental data obtained from the complex geometry and shear stress patterns offered by a mid-graft focal stenosis, where simulation results show good agreements with the experimental data.

  6. Boomerang-Shaped Chondro-Perichondral Graft Versus Temporalis Muscle Fascia Graft: Which One is to be Trusted?

    Science.gov (United States)

    Dundar, Riza; Kulduk, Erkan; Soy, Fatih Kemal; Aslan, Mehmet; Yükkaldiran, Ahmet; Çiftçi, Mehmet Ali

    2016-09-01

    The aim of this study was to compare anatomical and audiological results of boomerang-shaped chondroperichondrial graft (BSCPG) with temporal muscle fascia in type 1 tympanoplasties. Sixty-eight patients in BSCPG group and 54 patients in fascia group were evaluated. Otomicroscopic examination was done periodically till 24 months as for graft perforation, lateralization and retraction and mean air conduction threshold and airbone gap values were measured. At long term controls, in BSCPG group, rates of neomembrane, perforation, retraction and lateralization were 91.17 % (n = 62), 8.82 % (n = 6), 4.41 % (n = 3) and 0 % (n = 0), respectively. In fascia group, the corresponding rates were 79.62 % (n = 43), 20.37 % (n = 11), 12.96 % (n = 7) and 3.7 % (n = 2), respectively. In both groups, mean postoperative PTA and ABG values were significantly better while postoperative same values were significantly different between groups (p = 0.044 and 0.032, respectively). Compared to fascia, BSCPG is an ideal grafting technique in the repair of tympanic membrane perforations.

  7. Balsam-Pear-Skin-Like Porous Polyacrylonitrile Nanofibrous Membranes Grafted with Polyethyleneimine for Postcombustion CO2 Capture.

    Science.gov (United States)

    Zhang, Yufei; Guan, Jiming; Wang, Xianfeng; Yu, Jianyong; Ding, Bin

    2017-11-22

    Amine-containing sorbents have been extensively studied for postcombustion carbon dioxide (CO 2 ) capture because of their ability to chemisorb CO 2 from the flue gas. However, most sorbents are in the form of powders currently, which is not the ideal configuration for the flue gas separation because of the fragile nature and poor mechanical properties, resulting in blocking of the flow pipes and difficult recycling. Herein, we present a novel approach for the facile fabrication of flexible, robust, and polyethyleneimine-grafted (PEI-grafted) hydrolyzed porous PAN nanofibrous membranes (HPPAN-PEI NFMs) through the combination of electrospinning, pore-forming process, hydrolysis reaction, and the subsequent grafting technique. Excitingly, we find that all the resultant porous PAN (PPAN) fibers exhibit a balsam-pear-skin-like porous structure due to the selective removal of poly(vinylpyrrolidone) (PVP) from PAN/PVP fibers by water extraction. Significantly, the HPPAN-PEI NFMs retain their mesoporosity, as well as exhibit good thermal stability and prominent tensile strength (11.1 MPa) after grafting, guaranteeing their application in CO 2 trapping from the flue gas. When exposed to CO 2 at 40 °C, the HPPAN-PEI NFMs show an enhanced CO 2 adsorption capacity of 1.23 mmol g -1 (based on the overall quantity of the sample) or 6.15 mmol g -1 (based on the quantity of grafted PEI). Moreover, the developed HPPAN-PEI NFMs display significantly selective capture for CO 2 over N 2 and excellent recyclability. The CO 2 capacity retains 92% of the initial value after 20 adsorption-desorption cycle tests, indicating that the resultant HPPAN-PEI NFMs have good long-term stability. This work paves the way for fabricating NFM-based solid adsorption materials endowed with a porous structure applied to efficient postcombustion CO 2 capture.

  8. Pre-transplant levels of ficolin-3 are associated with kidney graft survival

    DEFF Research Database (Denmark)

    Bay, Jakob T; Hein, Estrid; Sørensen, Søren S

    2013-01-01

    . 97 blood donors served as controls. Ficolin-3, C4 and C3 were measured in pre-transplant as well as in control serum samples. In controls, deposition of ficolin-3, C4, C3 and the terminal complement complex (TCC) was measured in an assay based on acetylated albumin as matrix. The ficolin-3 levels...... correlated with the serum levels of C4 and C3. The serum levels of ficolin-3 correlated with the deposition of ficolin-3, C4, C3 and TCC. Survival analyses showed that high pre-transplant serum levels of ficolin-3 were associated with decreased graft survival. These results suggest an important role...

  9. Chest wall segmentation in automated 3D breast ultrasound scans.

    Science.gov (United States)

    Tan, Tao; Platel, Bram; Mann, Ritse M; Huisman, Henkjan; Karssemeijer, Nico

    2013-12-01

    In this paper, we present an automatic method to segment the chest wall in automated 3D breast ultrasound images. Determining the location of the chest wall in automated 3D breast ultrasound images is necessary in computer-aided detection systems to remove automatically detected cancer candidates beyond the chest wall and it can be of great help for inter- and intra-modal image registration. We show that the visible part of the chest wall in an automated 3D breast ultrasound image can be accurately modeled by a cylinder. We fit the surface of our cylinder model to a set of automatically detected rib-surface points. The detection of the rib-surface points is done by a classifier using features representing local image intensity patterns and presence of rib shadows. Due to attenuation of the ultrasound signal, a clear shadow is visible behind the ribs. Evaluation of our segmentation method is done by computing the distance of manually annotated rib points to the surface of the automatically detected chest wall. We examined the performance on images obtained with the two most common 3D breast ultrasound devices in the market. In a dataset of 142 images, the average mean distance of the annotated points to the segmented chest wall was 5.59 ± 3.08 mm. Copyright © 2012 Elsevier B.V. All rights reserved.

  10. Bone graft viability evaluated by three phase bone scan

    International Nuclear Information System (INIS)

    Ljiljana Jaukovic Rajko Spaic; Marijan Novakovic; Srbislav Stosic

    2004-01-01

    Bone defects resulting war injury can be replaced by microvascular bone grafts from fibula. Aim: The aim of this study was to assess the value of three phase (3P) bone scintigraphy in the early detection of the bone graft complications. Method: 3P bone scans were performed in four patients (two after mandible reconstruction with micro vascular fibular bone grafts, one after fibular transplantation for ulnar and one with humeral reconstruction). First dynamic phase scan was performed immediately after iv injection of 740 MBq Tc- 99m DPD, acquiring 15 two seconds duration frames. Second, early static scan was performed during next 300 seconds, and third, delayed scan three hours later. All scans were obtained under the bone graft region. The scans were evaluated using ROI under graft region and the corresponding contra lateral area. Blood flow in graft region was determined using first phase scan, and tracer uptake in the same region was determined using second and third phase scans. Results: in all patients blood flow in graft region was particularly normal. Tracer uptake in one of two patients with mandible reconstruction was diffusely increased in graft, strongly suggesting infection; In the other patient delayed scan showed no tracer uptake in graft center .Both patients with ulnar and humeral reconstruction showed only slightly decreased tracer uptake in bone grafts. 3 phase bone scintigraphy may play a role in the evaluation of bone graft viability by predicting the infection and necrosis. (authors)

  11. Direct observation of grafting interlayer phosphate in Mg/Al layered double hydroxides

    International Nuclear Information System (INIS)

    Shimamura, Akihiro; Kanezaki, Eiji; Jones, Mark I.; Metson, James B.

    2012-01-01

    The grafting of interlayer phosphate in synthetic Mg/Al layered double hydroxides with interlayer hydrogen phosphate (LDH-HPO 4 ) has been studied by XRD, TG/DTA, FT-IR, XPS and XANES. The basal spacing of crystalline LDH-HPO 4 decreases in two stages with increasing temperature, from 1.06 nm to 0.82 nm at 333 K in the first transition, and to 0.722 nm at 453 K in the second. The first stage occurs due to the loss of interlayer water and rearrangement of the interlayer HPO 4 2− . In the second transition, the interlayer phosphate is grafted to the layer by the formation of direct bonding to metal cations in the layer, accompanied by a change in polytype of the crystalline structure. The grafted phosphate becomes immobilized and cannot be removed by anion-exchange with 1-octanesulfonate. The LDH is amorphous at 743 K but decomposes to Mg 3 (PO 4 ) 2 , AlPO 4 , MgO and MgAl 2 O 4 after heated to 1273 K. - Graphical abstract: The cross section of the synthetic Mg, Al layered double hydroxides in Phase 1, with interlayer hydrogen phosphate Phase 2, and with grafted phosphate, Phase 3. Highlights: ► The grafting of hydrogen phosphate intercalated Mg/Al-LDH has been studied. ► The basal spacing of crystalline LDH-HPO 4 decreases in two stages with increasing temperature. ► The first decrease is due to loss of interlayer water, the second is attributed to phosphate grafting. ► The grafted interlayer phosphate becomes immobilized and cannot be removed by anion-exchange.

  12. Grafting and curing

    International Nuclear Information System (INIS)

    Garnett, J.L.; Loo-Teck Ng; Visay Viengkhou

    1998-01-01

    Progress in radiation grafting and curing is briefly reviewed. The two processes are shown to be mechanistically related. The parameters influencing yields are examined particularly for grafting. For ionising radiation grafting systems (EB and gamma ray) these include solvents, substrate and monomer structure, dose and dose-rate, temperature and more recently role of additives. In addition, for UV grafting, the significance of photoinitiators is discussed. Current applications of radiation grafting and curing are outlined. The recent development of photoinitiator free grafting and curing is examined as well as the potential for the new excimer laser sources. The future application of both grafting and curing is considered, especially the significance of the occurrence of concurrent grafting during cure and its relevance in environmental considerations

  13. Prediction of coronary artery bypass graft flow

    International Nuclear Information System (INIS)

    Tamiya, Eiji; Hada, Yoshiyuki; Asano, Ken-ichi; Iio, Masahiro.

    1991-01-01

    To predict the coronary artery bypass graft (CABG) flow based on the time density curve (TDC) obtained from the digital subtraction aortograms (DSA), we developed a pulsatile CABG model (perfusion pressure 60,130 mmHg, pulse rate 53,126/min, cardiac output 3-7 l/min, diameter of the graft 2.1∼6.0 mm). After positioning the regions of interest (ROI), we injected contrast medium(5∼40 ml/sec, 5∼40 ml) into the outlet conduit. Concerning the TDCs, we calculated appearance time (Ta), peak densities (Dp), peak time (Tp), disappearance time (Td), integral of TDC, ΔTp (difference of Tp between two ROI) and ΔTa (difference of Ta between two ROI). Perfusion pressure, graft flow and output curve were similar to those of patients with CABG. Ta, Tp, Td, and ΔTp were affected by both the injection rate and the volume of the contrast medium; while Dp and the TDC integral were only affected by the latter parameter. Under the same conditions of contrast medium injection, the TDC depended strongly on graft flow, diameter of the graft, output and pulse rate. 21.6+0.92π·d 2 /4·Δ1/ΔTp·60 provided the most accurate estimation of CABG flow (r=0.865, p<0.01). We conclude that densitometric analysis of DSA may be useful in the prediction of CABG flow. (author)

  14. Haptoglobin 2-2 Genotype, Patient, and Graft Survival in Renal Transplant Recipients

    DEFF Research Database (Denmark)

    Dupont, Laust; Eide, Ivar Anders; Hartmann, Anders

    2017-01-01

    Background: Cardiovascular disease is the leading cause of death in renal transplant recipients. An association between haptoglobin genotype 2-2 and cardiovascular disease has been found in patients with diabetes mellitus and liver transplant recipients. To date, the role of haptoglobin genotype...... after renal transplantation has not been studied. Methods: In this single-center retrospective cohort study of 1975 adult Norwegian transplant recipients, who underwent transplantation between 1999 and 2011, we estimated the risk of all-cause and cardiovascular mortality and overall and death...... transplant recipients, we could not demonstrate any association between haptoglobin 2-2 genotype and patient or graft survival after renal transplantation....

  15. Reproducibility of Corneal Graft Thickness measurements with COLGATE in patients who have undergone DSAEK (Descemet Stripping Automated Endothelial Keratoplasty

    Directory of Open Access Journals (Sweden)

    Wong Melissa HY

    2012-08-01

    Full Text Available Abstract Background The CorneaL GrAft Thickness Evaluation (COLGATE system was recently developed to facilitate the evaluation of corneal graft thickness from OCT images. Graft thickness measurement can be a surrogate indicator for detecting graft failure or success. The purpose of this study was to determine the reproducibility of the COLGATE system in measuring DSAEK graft area between two observers. Methods This was a prospective case series in which 50 anterior segment OCT images of patients who had undergone DSAEK in either eye were analysed. Two observers (MW, AC independently obtained the image analysis for the graft area using both semi automated and automated method. One week later, each observer repeated the analysis for the same set of images. Bland-Altman analysis was performed to analyze inter and intra observer agreement. Results There was strong intraobserver correlation between the 2 semi automated readings obtained by both observers. (r = 0.936 and r = 0.962. Intraobserver ICC for observer 1 was 0.936 (95% CI 0.890 to 0.963 and 0.967 (95% CI 0.942 to 0.981 for observer 2. Likewise, there was also strong interobserver correlation (r = 0.913 and r = 0.969. The interobserver ICC for the first measurements was 0.911 (95% CI 0.849 to 0.949 and 0.968 (95% CI 0.945 to 0.982 for the second. There was statistical difference between the automatic and the semi automated readings for both observers (p = 0.006, p = 0.003. The automatic readings gave consistently higher values than the semi automated readings especially in thin grafts. Conclusion The analysis from the COLGATE programme can be reproducible between different observers. Care must be taken when interpreting the automated analysis as they tend to over estimate measurements.

  16. Hydrophobic modification of cellulose isolated from Agave angustifolia fibre by graft copolymerisation using methyl methacrylate.

    Science.gov (United States)

    Rosli, Noor Afizah; Ahmad, Ishak; Abdullah, Ibrahim; Anuar, Farah Hannan; Mohamed, Faizal

    2015-07-10

    Graft copolymerisation of methyl methacrylate (MMA) onto Agave angustifolia was conducted with ceric ammonium nitrate (CAN) as the redox initiator. The maximum grafting efficiency was observed at CAN and MMA concentrations of 0.91 × 10(-3) and 5.63 × 10(-2)M, respectively, at 45°C for 3h reaction time. Four characteristic peaks at 2995, 1738, 1440, and 845 cm(-1), attributed to PMMA, were found in the IR spectrum of grafted cellulose. The crystallinity index dropped from 0.74 to 0.46, while the thermal stability improved upon grafting. The water contact angle increased with grafting yield, indicating increased hydrophobicity of cellulose. SEM images showed the grafted cellulose to be enlarged and rougher. The changes in the physical nature of PMMA-grafted cellulose can be attributed to the PMMA grafting in the amorphous regions of cellulose, causing it to expand at the expense of the crystalline component. Copyright © 2015 Elsevier Ltd. All rights reserved.

  17. Case Series: Keratolimbal Allograft as a Patch Graft for Glaucoma Drainage Devices.

    Science.gov (United States)

    Ahmed, Sarah F; Schmutz, Mason; Mosaed, Sameh

    2017-09-01

    Tube exposure remains one of the most common complications after glaucoma drainage device (GDD) implantation, despite various types of patch grafts available today. We present a 4 patient case series following the effectivity of the keratolimbal allograft (KLAL) as a patch graft for cases of tube exposure. Given its inherent population of stem cells, our hypothesis was that this highly replicative, biological tissue would provide an adequate means of glaucoma tube coverage. The subset of patients chosen for the KLAL patch graft all had a history of abnormally scarred conjunctiva or thin sclera. The aim of utilizing the KLAL patch with its associated donor conjunctival and scleral ring was also to provide additional reinforcement and adequate tube coverage in the setting of compromised native tissue. Four patients comprised of 2 males and 2 females with a minimum postoperative period of 12 months. All GDDs were initially implanted with a limbal-based incision using either Ahmed glaucoma valve or Baerveldt drainage implant. Three of the 4 patients received the KLAL patch graft after tube exposure with scleral patch graft and 1 patient received KLAL as the primary graft during initial tube placement. Two of the 4 eyes experienced tube re-exposure postoperatively at 2 and 3 months, respectively. Both of these cases had a history of prior tube exposure after scleral patch graft and both were tubes placed in the pars plana. Interestingly, the patients with failed grafts were younger with a history of more ocular surgeries as compared with the patients with graft viable eyes. Through our case series, we found that the KLAL utilized as a patch graft over GDD tubes has the potential for favorable outcomes in certain subtypes of eyes. Although further large scale investigation will be necessary to better define the risk factors associated with graft failure, proving the graft's viability is a crucial first step.

  18. The role of the notochord in amniote vertebral column segmentation.

    Science.gov (United States)

    Ward, Lizzy; Pang, Angel S W; Evans, Susan E; Stern, Claudio D

    2018-07-01

    The vertebral column is segmented, comprising an alternating series of vertebrae and intervertebral discs along the head-tail axis. The vertebrae and outer portion (annulus fibrosus) of the disc are derived from the sclerotome part of the somites, whereas the inner nucleus pulposus of the disc is derived from the notochord. Here we investigate the role of the notochord in vertebral patterning through a series of microsurgical experiments in chick embryos. Ablation of the notochord causes loss of segmentation of vertebral bodies and discs. However, the notochord cannot segment in the absence of the surrounding sclerotome. To test whether the notochord dictates sclerotome segmentation, we grafted an ectopic notochord. We find that the intrinsic segmentation of the sclerotome is dominant over any segmental information the notochord may possess, and no evidence that the chick notochord is intrinsically segmented. We propose that the segmental pattern of vertebral bodies and discs in chick is dictated by the sclerotome, which first signals to the notochord to ensure that the nucleus pulposus develops in register with the somite-derived annulus fibrosus. Later, the notochord is required for maintenance of sclerotome segmentation as the mature vertebral bodies and intervertebral discs form. These results highlight differences in vertebral development between amniotes and teleosts including zebrafish, where the notochord dictates the segmental pattern. The relative importance of the sclerotome and notochord in vertebral patterning has changed significantly during evolution. Copyright © 2018 The Authors. Published by Elsevier Inc. All rights reserved.

  19. Complications and Adverse Events of a Randomized Clinical Trial Comparing 3 Graft Types for ACL Reconstruction.

    Science.gov (United States)

    Mohtadi, Nicholas; Barber, Rhamona; Chan, Denise; Paolucci, Elizabeth Oddone

    2016-05-01

    Complications/adverse events of anterior cruciate ligament (ACL) surgery are underreported, despite pooled level 1 data in systematic reviews. All adverse events/complications occurring within a 2-year postoperative period after primary ACL reconstruction, as part of a large randomized clinical trial (RCT), were identified and described. Prospective, double-blind randomized clinical trial. Patients and the independent trained examiner were blinded to treatment allocation. University-based orthopedic referral practice. Three hundred thirty patients (14-50 years; 183 males) with isolated ACL deficiency were intraoperatively randomized to ACL reconstruction with 1 autograft type. Graft harvest and arthroscopic portal incisions were identical. Patients were equally distributed to patellar tendon (PT), quadruple-stranded hamstring tendon (HT), and double-bundle (DB) hamstring autograft ACL reconstruction. Adverse events/complications were patient reported, documented, and diagnoses confirmed. Two major complications occurred: pulmonary embolism and septic arthritis. Twenty-four patients (7.3%) required repeat surgery, including 25 separate operations: PT = 7 (6.4%), HT = 9 (8.2%), and DB = 8 (7.3%). Repeat surgery was performed for meniscal tears (3.6%; n = 12), intra-articular scarring (2.7%; n = 9), chondral pathology (0.6%; n = 2), and wound dehiscence (0.3%; n = 1). Other complications included wound problems, sensory nerve damage, muscle tendon injury, tibial periostitis, and suspected meniscal tears and chondral lesions. Overall, more complications occurred in the HT/DB groups (PT = 24; HT = 31; DB = 45), but more PT patients complained of moderate or severe kneeling pain (PT = 17; HT = 9; DB = 4) at 2 years. Overall, ACL reconstructive surgery is safe. Major complications were uncommon. Secondary surgery was necessary 7.3% of the time for complications/adverse events (excluding graft reinjury or revisions) within the first 2 years. Level 1 (therapeutic studies

  20. High Rate Micromechanical Behavior of Grafted Polymer Nanoparticle Films

    Science.gov (United States)

    Thomas, Edwin

    We report the ultra high strain rate behavior of films comprised of polymer grafted nanoparticles (NPs) and compare the results to homopolymer films. The films are formed by flow coating a suspension of polystyrene (PS) chains of 230 kg/mol grafted to 16nm diameter SiO2\\ at a graft density of 0.6 chains/nm2 resulting a film with 1 vol % SiO2. Films of 267 kg/mol PS were also flow coated and both films were impacted at velocities 350-700 ms-1 using 3.7 micron SiO2\\ projectiles to achieve increments in kinetic energy (KE) of 1:2:4. The KE of the projectiles before and after penetration was measured to determine the penetration energy. TEM and SEM suggest the projectile initially induces plastic flow due to the adiabatic temperature rise from impact. As the projectile deforms the film, the lower magnitude, biaxial stress state in the peripherial regions causes material microvoid formation and initiation of craze growth in the radial and tangential directions. The anchoring of the grafted polymer chains to the NPs increases the penetration energy relative to the pure homopolymer by 50% and the films capacity to delocalize the impact by 200%. These results suggest that highly grafted NP films may be useful in lightweight protection systems. In collaboration with Omri Fried, Olawale Lawal, Yang Jiao, Victor Hsaio, Thevamaran Ramathasan, Mujin Zhou, Richard Vaia.

  1. An alternative graft fixation technique for scaphoid nonunions treated with vascular bone grafting.

    Science.gov (United States)

    Korompilias, Anastasios V; Lykissas, Marios G; Kostas-Agnantis, Ioannis P; Gkiatas, Ioannis; Beris, Alexandros E

    2014-07-01

    To present our experience with vascularized bone grafting based on the 1,2-intercompartmental supraretinacular artery for the management of established scaphoid nonunion and to investigate the efficacy of graft immobilization with a combination of Kirschner wires and transarticular external fixation. A retrospective chart and radiographic review was conducted for patients with the diagnosis of scaphoid nonunion of the proximal pole or the waist treated with the 1,2-intercompartmental supraretinacular artery-based vascularized graft and fixed with a combination of Kirschner wires and transarticular external fixation between 2007 and 2011. We observed 23 consecutive patients for a mean of 34 ± 4 months. All patients were males with mean age of 25 ± 5 years. All patients had scaphoid nonunion and associated humpback deformity. The mean duration of nonunion was 7 ± 1 months. All scaphoid nonunions united after the index procedure at a mean of 10 ± 1 weeks. Two patients had avascular necrosis of the proximal pole based on the preoperative magnetic resonance imaging findings. After surgery, deformity correction was achieved in all patients, as recorded by the decrease in the lateral intrascaphoid angle and the increase in the dorsal scaphoid angle. At the last follow-up, no patients reported wrist pain. The mean Disabilities of the Arm, Shoulder, and Hand score improved significantly from 32 ± 12 before the operation to 5 ± 3 at the last postoperative visit. All patients showed statistically significant improvement in the range of motion and the grip strength of the involved wrist. The results of this study support the combined use of Kirschner wires and transarticular external fixation for fixation of a 1,2-intercompartmental supraretinacular artery-based vascular bone graft in the treatment of scaphoid nonunions. Therapeutic IV. Copyright © 2014 American Society for Surgery of the Hand. Published by Elsevier Inc. All rights reserved.

  2. Graft Patency in Long-term Survivors after Renovisceral Debranching with VORTEC

    Energy Technology Data Exchange (ETDEWEB)

    Winklehner, Anna, E-mail: anna.winklehner@usz.ch; Nguyen-Kim, Thi Dan Linh, E-mail: thidanlinh.nguyen@usz.ch; Pfammatter, Thomas, E-mail: thomas.pfammatter@usz.ch [University Hospital Zurich, Institute of Diagnostic and Interventional Radiology (Switzerland); Rancic, Zoran, E-mail: zoran.rancic@usz.ch; Mayer, Dieter, E-mail: dieter.mayer@usz.ch; Lachat, Mario, E-mail: mario.lachat@usz.ch [University Hospital Zurich, Clinic for Cardiovascular Surgery (Switzerland); Frauenfelder, Thomas, E-mail: Thomas.Frauenfelder@usz.ch [University Hospital Zurich, Institute of Diagnostic and Interventional Radiology (Switzerland)

    2015-06-15

    PurposeThis study was designed to evaluate retrospectively the long-term stent-graft patency after renovisceral revascularization with Viabahn Open Revascularization Technique (VORTEC) using computed tomography angiography (CTA) and magnetic resonance angiography (MRA).MethodsIn 34 patients (seven women; mean age 72 ± 8 years) with aortic aneurysm, 63 renovisceral vessels (i.e., 54 renal, nine visceral arteries) were revascularized with VORTEC between 2004 and 2009. All patients obtained a pre- and postinterventional CTA and at least one follow-up CTA or MRA after 6 or more months following intervention (median follow up: 43 months). Detection of bypass occlusion, bypass stenosis, infolding, stent-graft fractures and dislocations, and kidney shrinkage were noted by two readers in consensus. Furthermore, mortality during follow-up was assessed using the medical report.ResultsDuring follow-up, 12.6 % of stent-grafts occluded. Cumulative patency rate was 95.2 ± 2.7 % at 12 months, 87.7 ± 4.4 % at 24 and 36 months, and 84.7 ± 5.2 % at 48, 60, 72, 84, and 89 months, respectively. Overall, 19 % of stent-grafts (12/63) developed bypass stenosis (<50 %, 10 stent-grafts; > 50 %, 2 stent-grafts), in one case stenosis (>70 %) was suspected to be hemodynamically significant. No secondary dislocation, no infolding of renovisceral stent-grafts, and no stent-graft fracture occurred. Kidney shrinkage occurred in nine patients, primarily in patients with an occluded Viabahn (n = 7). Eleven patients (32.3 %) died within the follow-up time period.ConclusionsIn long-term survivors after VORTEC cumulative patency rate remained high, and no stent-graft fractures or secondary dislocations occurred.

  3. [Segmental tracheal resection and anastomosis for the treatment of cicatricial stenosis in cervical tracheal].

    Science.gov (United States)

    Cui, P C; Luo, J S; Liu, Z; Bian, K; Guo, Z H; Ma, R N

    2016-02-01

    To evaluate the efficacy of segmental tracheal resection with end-to-end anastomosis for cicatricial cervical tracheal stenosis. The clinical outcomes of 40 patients treated with tracheal resection were retrospectively reviewed. There were 28 male patients and 12 female patients with the age ranged from 6 to 64 years (mean 33.7 years). The degree of stenosis was classified according to Myer-Cotton classification as follows: grade Ⅱ (n=7), grade Ⅲ (n=22) and grade Ⅳ (n=11). The stenosis extension ranged from 1.0 to 4.3 cm (mean 2.5 cm). The causes of the stenosis were postintubation (n=33), cervical trauma (n=6) and resection of tracheal neoplasm (n=1). Thirty-four(85.0%) patients were decannulated and 6 failed. Of the 6 patients failed, 4 were decannulated after reoperation with the sternohyoid myocutaneous flap or thyroid alar cartilage graft. Complications occurred in 10 patients. In 8 patients granulation tissues formed at the site of the tracheal anastomosis, which needed endoscopic resction, and in 2 patients anastomosic dehiscence occurred. No injury to recurrent laryngeal nerve or trachoesophageal fistula occurred. Segmental tracheal resection with end-to-end anastomosis is an effective surgical method for tracheal stenosis, which has a higher successful rate for primary operation and shorter therapeutic period.

  4. Cause of the Scion Death in Green Pepper Grafting System by a Tobamovirus

    Directory of Open Access Journals (Sweden)

    Gug-Seoun Choi

    2011-08-01

    Full Text Available This experiment was attempted to investigate a cause of the scion death in green pepper grafting system. A tobamovirus particle examined in the rootstock of the sample but not in the scion showing necrosis. The virus isolated from the rootstock was identified as Pepper mild mottle virus (PMMoV, pepper tobamovirus pathotype P1.2. (PMMoV-2, by nucleotide sequence analysis and host plant reaction. The virus isolate infected systematically in 6 commercial rootstock varieties using for green pepper grafting seedling production. Green pepper varieties ``Long green mart`` and ``Daechan`` represented resistance to the virus showing local lesions only on the inoculated leaves and ``Manitda`` was systematically infected. In the experiment with grafting ``Long green mart`` or ``Daechan`` onto the those rootstocks, the upper leaves of the scions first showed vein necrosis and wilt symptoms 7 days after inoculation with PMMoV-2 on the cotyledon of the rootstock, following to the scion stem necrosis and then only the scion death. The virus was detected in the rootstock but not in the scion. However, ``Manitda`` of susceptible variety in the grafting system showed mottle symptom on the leaves of the scion but not necrosis on the plant. PMMoV-3 isolate, pepper tobamovirus pathotype P1.2.3, did not cause the scion death in the grafting system. All of the varieties were susceptible to PMMoV-3. These results suggest that the scion death is caused by infecting with pepper tobamovirus pathotype P1.2. in the green pepper grafting system combined with the susceptible rootstock and the resistance scion to the virus pathotype.

  5. Double-layered collagen graft to the radial forearm free flap donor sites without skin graft.

    Science.gov (United States)

    Park, Tae-Jun; Kim, Hong-Joon; Ahn, Kang-Min

    2015-12-01

    Radial forearm free flap is the most reliable flap for intraoral soft tissue reconstruction after cancer ablation surgery. However, unesthetic scar of the donor site and the need for a second donor site for skin graft are major disadvantages of the forearm flap. The purpose of this study was to report the clinical results of double-layered collagen graft to the donor site of the forearm free flap without skin graft. Twenty-two consecutive patients who underwent oral cancer ablation and forearm reconstruction between April 2010 and November 2013 were included in this study. Male to female ratio was 12:10, and average age was 61.0 years old (27-84). Double-layered collagen was grafted to the donor site of the forearm free flap and healed for secondary intention. Upper silicone had been trimmed at the periphery during secondary intention, and dry dressing was used. Postoperative scar healing and esthetic results and function were evaluated. An average follow-up period was 34.9 months. The scar area was decreased to 63.9 % in average. The complete healing was obtained between 1.5 and 3 months according to the defect size. There was no functional defect or impairment 3 months after operation. All patients were satisfied with the esthetic results. Three patients died of recurred cancer. Double-layered collagen graft was successfully performed in this study. Without the thigh skin graft, patients had experienced less painful postoperative healing periods and discomfort.

  6. Quantification and visualization of carotid segmentation accuracy and precision using a 2D standardized carotid map

    International Nuclear Information System (INIS)

    Chiu, Bernard; Ukwatta, Eranga; Shavakh, Shadi; Fenster, Aaron

    2013-01-01

    This paper describes a framework for vascular image segmentation evaluation. Since the size of vessel wall and plaque burden is defined by the lumen and wall boundaries in vascular segmentation, these two boundaries should be considered as a pair in statistical evaluation of a segmentation algorithm. This work proposed statistical metrics to evaluate the difference of local vessel wall thickness (VWT) produced by manual and algorithm-based semi-automatic segmentation methods (ΔT) with the local segmentation standard deviation of the wall and lumen boundaries considered. ΔT was further approximately decomposed into the local wall and lumen boundary differences (ΔW and ΔL respectively) in order to provide information regarding which of the wall and lumen segmentation errors contribute more to the VWT difference. In this study, the lumen and wall boundaries in 3D carotid ultrasound images acquired for 21 subjects were each segmented five times manually and by a level-set segmentation algorithm. The (absolute) difference measures (i.e., ΔT, ΔW, ΔL and their absolute values) and the pooled local standard deviation of manually and algorithmically segmented wall and lumen boundaries were computed for each subject and represented in a 2D standardized map. The local accuracy and variability of the segmentation algorithm at each point can be quantified by the average of these metrics for the whole group of subjects and visualized on the 2D standardized map. Based on the results shown on the 2D standardized map, a variety of strategies, such as adding anchor points and adjusting weights of different forces in the algorithm, can be introduced to improve the accuracy and variability of the algorithm. (paper)

  7. [Penile augmentation and elongation using autologous dermal-fat strip grafting].

    Science.gov (United States)

    Yang, Zhe; Li, Yang-qun; Tang, Yong; Chen, Wen; Li, Qiang; Zhou, Chuan-de; Zhao, Mu-xin; Hu, Chun-mei

    2012-05-01

    To investigate the effect of autologous dermal-fat strip grafting in penile augmentation and elongation. From May 2004 to December 2010, 24 patients underwent penile enhancement with free dermal-fat strip grafting. Through suprapubic incision, the superior suspensory ligament and part deep suspensory ligament are cutted off to lengthen the penis. The resulted dead space is filled with the autologous dermal-fat strip (6.0-9.5 cm in length, 1.2-1.5 cm in width and 0.6-0.8 cm in depth) to enhance the penis. Primary healing was achieved in 23 cases. Incisional fat liquefaction happened in one case which healed after dressing change. The penile appearance was satisfactory both at rest or erection. The penile length and circumference increased by 2.5-4.8 cm (average, 3.2 cm) and 1.8-3.0 cm (average, 2.4 cm), respectively. 18 patients were followed up for 3 months to 5 years. All the patients were satisfactory on the cosmetic and functional results. No complication happened. It is safe and effective for penile augmention and elongation with autologous dermal-fat strip grafting and disconnection of penile suspensory ligament.

  8. Chitin biological absorbable catheters bridging sural nerve grafts transplanted into sciatic nerve defects promote nerve regeneration.

    Science.gov (United States)

    Wang, Zhi-Yong; Wang, Jian-Wei; Qin, Li-Hua; Zhang, Wei-Guang; Zhang, Pei-Xun; Jiang, Bao-Guo

    2018-06-01

    To investigate the efficacy of chitin biological absorbable catheters in a rat model of autologous nerve transplantation. A segment of sciatic nerve was removed to produce a sciatic nerve defect, and the sural nerve was cut from the ipsilateral leg and used as a graft to bridge the defect, with or without use of a chitin biological absorbable catheter surrounding the graft. The number and morphology of regenerating myelinated fibers, nerve conduction velocity, nerve function index, triceps surae muscle morphology, and sensory function were evaluated at 9 and 12 months after surgery. All of the above parameters were improved in rats in which the nerve graft was bridged with chitin biological absorbable catheters compared with rats without catheters. The results of this study indicate that use of chitin biological absorbable catheters to surround sural nerve grafts bridging sciatic nerve defects promotes recovery of structural, motor, and sensory function and improves muscle fiber morphology. © 2018 John Wiley & Sons Ltd.

  9. Graft copolimerization of hydrophilic monomers onto irradiated polypropylene fibers

    International Nuclear Information System (INIS)

    Sundardi, F.

    1978-01-01

    A method of graft copolymerization of hydrophilic monomers, such as 1-vinyl-2-pyrrolidone, acrylonitrile, acrylic acid, and acrylamide, onto irradiated polypropylene fibers has been studied. γ ray as well as electron beam were employed for the irradiation processes. Graft-copolymerization kinetics and the properties of grafted fibers have been investigated. Moisture regain, dyes absorption, and melting point of the grafted fibers were found to increase with the increasing of the degree of grafting. Polypropylene for 1-vinyl-2-pyrrolidone grafted fibers showed excellent dye absorption for almost all kinds of dyes such as direct, basic, acid, reactive, disper, and naphthol dyes. However, for polypropylene acrylic acid grafted fibers, the colorfastness to washing was found to be unsatisfactory. The colorfastness to washing for polypropylene 1-vinyl-2-pyrrolidone grafted fibers was found to be fairly good for certain types of dyes such as vat and naphthol dyes. (author)

  10. Warfarin improves the outcome of infrainguinal vein bypass grafting at high risk for failure.

    Science.gov (United States)

    Sarac, T P; Huber, T S; Back, M R; Ozaki, C K; Carlton, L M; Flynn, T C; Seeger, J M

    1998-09-01

    Patients with marginal venous conduit, poor arterial runoff, and prior failed bypass grafts are at high risk for infrainguinal graft occlusion and limb loss. We sought to evaluate the effects of anticoagulation therapy after autogenous vein infrainguinal revascularization on duration of patency, limb salvage rates, and complication rates in this subset of patients. This randomized prospective trial was performed in a university tertiary care hospital and in a Veterans Affairs Hospital. Fifty-six patients who were at high risk for graft failure were randomized to receive aspirin (24 patients, 27 bypass grafts) or aspirin and warfarin (WAR; 32 patients, 37 bypass grafts). All patients received 325 mg of aspirin each day, and the patients who were randomized to warfarin underwent anticoagulation therapy with heparin immediately after surgery and then were started on warfarin therapy to maintain an international normalized ratio between 2 and 3. Perioperative blood transfusions and complications were compared with the Student t test or with the chi2 test. Graft patency rates, limb salvage rates, and survival rates were compared with the Kaplan-Meier method and the log-rank test. Sixty-one of the 64 bypass grafts were performed for rest pain or tissue loss, and 3 were performed for short-distance claudication. There were no differences between the groups in ages, indications, bypass graft types, risk classifications (ie, conduit, runoff, or graft failure), or comorbid conditions (except diabetes mellitus). The cumulative 5-year survival rate was similar between the groups. The incidence rate of postoperative hematoma (32% vs 3.7%; P = .004) was greater in the WAR group, but no differences were seen between the WAR group and the aspirin group in the number of packed red blood cells transfused, in the incidence rate of overall nonhemorrhagic wound complications, or in the overall complication rate (62% vs 52%). The immediate postoperative primary graft patency rates (97.3

  11. 3D GEOMARKETING SEGMENTATION: A HIGHER SPATIAL DIMENSION PLANNING PERSPECTIVE

    Directory of Open Access Journals (Sweden)

    A. Suhaibah

    2016-09-01

    Full Text Available Geomarketing is a discipline which uses geographic information in the process of planning and implementation of marketing activities. It can be used in any aspect of the marketing such as price, promotion or geo targeting. The analysis of geomarketing data use a huge data pool such as location residential areas, topography, it also analyzes demographic information such as age, genre, annual income and lifestyle. This information can help users to develop successful promotional campaigns in order to achieve marketing goals. One of the common activities in geomarketing is market segmentation. The segmentation clusters the data into several groups based on its geographic criteria. To refine the search operation during analysis, we proposed an approach to cluster the data using a clustering algorithm. However, with the huge data pool, overlap among clusters may happen and leads to inefficient analysis. Moreover, geomarketing is usually active in urban areas and requires clusters to be organized in a three-dimensional (3D way (i.e. multi-level shop lots, residential apartments. This is a constraint with the current Geographic Information System (GIS framework. To avoid this issue, we proposed a combination of market segmentation based on geographic criteria and clustering algorithm for 3D geomarketing data management. The proposed approach is capable in minimizing the overlap region during market segmentation. In this paper, geomarketing in urban area is used as a case study. Based on the case study, several locations of customers and stores in 3D are used in the test. The experiments demonstrated in this paper substantiated that the proposed approach is capable of minimizing overlapping segmentation and reducing repetitive data entries. The structure is also tested for retrieving the spatial records from the database. For marketing purposes, certain radius of point is used to analyzing marketing targets. Based on the presented tests in this paper

  12. Preparation and characterization of poly(acrylic acid)-hydroxyethyl cellulose graft copolymer.

    Science.gov (United States)

    Abdel-Halim, E S

    2012-10-01

    Poly(acrylic acid) hydroxyethyl cellulose [poly(AA)-HEC] graft copolymer was prepared by polymerizing acrylic acid (AA) with hydroxyethyl cellulose (HEC) using potassium bromate/thiourea dioxide (KBrO(3)/TUD) as redox initiation system. The polymerization reaction was carried out under a variety of conditions including concentrations of AA, KBrO(3) and TUD, material to liquor ratio and polymerization temperature. The polymerization reaction was monitored by withdrawing samples from the reaction medium and measuring the total conversion. The rheological properties of the poly(AA)-HEC graft copolymer were investigated. The total conversion and rheological properties of the graft copolymer depended on the ratio of KBrO(3) to TUD and on acrylic acid concentration as well as temperature and material to liquor ratio. Optimum conditions of the graft copolymer preparation were 30 mmol KBrO(3) and 30 mmol TUD/100g HEC, 100% AA (based on weight of HEC), duration 2h at temperature 50 °C using a material to liquor ratio of 1:10. Copyright © 2012. Published by Elsevier Ltd.

  13. Abaca/polyester nonwoven fabric functionalization for metal ion adsorbent synthesis via electron beam-induced emulsion grafting

    International Nuclear Information System (INIS)

    Madrid, Jordan F.; Ueki, Yuji; Seko, Noriaki

    2013-01-01

    A metal ion adsorbent was developed from a nonwoven fabric trunk material composed of both natural and synthetic polymers. A pre-irradiation technique was used for emulsion grafting of glycidyl methacrylate (GMA) onto an electron beam irradiated abaca/polyester nonwoven fabric (APNWF). The dependence of degree of grafting (Dg), calculated from the weight of APNWF before and after grafting, on absorbed dose, reaction time and monomer concentration were evaluated. After 50 kGy irradiation with 2 MeV electron beam and subsequent 3 h reaction with an emulsion consisting of 5% GMA and 0.5% polyoxyethylene sorbitan monolaurate (Tween 20) surfactant in deionized water at 40 °C, a grafted APNWF with a Dg greater than 150% was obtained. The GMA-grafted APNWF was further modified by reaction with ethylenediamine (EDA) in isopropyl alcohol at 60 °C to introduce amine functional groups. After a 3 h reaction with 50% EDA, an amine group density of 2.7 mmole/gram adsorbent was achieved based from elemental analysis. Batch adsorption experiments were performed using Cu 2+ and Ni 2+ ions in aqueous solutions with initial pH of 5 at 30 °C. Results show that the adsorption capacity of the grafted adsorbent for Cu 2+ is four times higher than Ni 2+ ions. - Highlights: • An amine type adsorbent from abaca/polyester nonwoven fabric was synthesized. • Pre-irradiation method was used in grafting glycidyl methacrylate on nonwoven fabric. • Radiation-induced grafting was performed with monomer in emulsion state. • The calculated adsorption capacity for Cu 2+ is four times higher than Ni 2+ ions. • Grafted adsorbent can remove Cu 2+ faster than a chemically similar commercial resin

  14. Zwitterionic phosphorylcholine grafted chitosan nanofiber: Preparation, characterization and in-vitro cell adhesion behavior

    Energy Technology Data Exchange (ETDEWEB)

    Oktay, Burcu; Kayaman-Apohan, Nilhan, E-mail: napohan@marmara.edu.tr; Süleymanoğlu, Mediha; Erdem-Kuruca, Serap

    2017-04-01

    In this study, zwitterionic phosphorylcholine grafted electrospun chitosan fiber was accomplished in three steps: (1) Azide groups on the chitosan were regioselectively replaced with hydroxyl side group and then the product was electrospun. (2) Chitosan based macroinitiator was prepared using an azide-alkyne click reaction from azide-functionalized electrospun chitosan fiber. (3) Poly(2-methacryloyloxyethyl phosphorylcholine) (MPC) was grafted onto the electrospun chitosan fiber by atom transfer radical polymerization (ATRP) in order to enhance cellular viability and proliferation of 3T3, ECV and Saos. The structure of surface modified chitosan was characterized by Fourier transform infrared spectrometer (FT-IR) and {sup 1}H nuclear magnetic resonance ({sup 1}H NMR). The surface morphology of the nanofibers was investigated by scanning electron microscope (SEM). In-vitro cellular attachment and spreading experiments of 3T3, ECV304 and Saos were performed on electrospun chitosan fibers in the presence and the absence of MPC grafting. Poly(MPC) grafted electrospun fiber showed an excellent performance due to phosphorylcholine groups mimicking the natural phospholipid. - Highlights: • Chitosan was functionalized in a controlled way. • Poly(MPC) grafted electrospun chitosan fiber was prepared by click and ATRP. • Controlled molecular architecture was achieved. • Cellular attachment and spreading efficiency of the nanofiber were investigated. • These nanofibers have potential applications in tissue engineering with tissue.

  15. 3D knee segmentation based on three MRI sequences from different planes.

    Science.gov (United States)

    Zhou, L; Chav, R; Cresson, T; Chartrand, G; de Guise, J

    2016-08-01

    In clinical practice, knee MRI sequences with 3.5~5 mm slice distance in sagittal, coronal, and axial planes are often requested for the knee examination since its acquisition is faster than high-resolution MRI sequence in a single plane, thereby reducing the probability of motion artifact. In order to take advantage of the three sequences from different planes, a 3D segmentation method based on the combination of three knee models obtained from the three sequences is proposed in this paper. In the method, the sub-segmentation is respectively performed with sagittal, coronal, and axial MRI sequence in the image coordinate system. With each sequence, an initial knee model is hierarchically deformed, and then the three deformed models are mapped to reference coordinate system defined by the DICOM standard and combined to obtain a patient-specific model. The experimental results verified that the three sub-segmentation results can complement each other, and their integration can compensate for the insufficiency of boundary information caused by 3.5~5 mm gap between consecutive slices. Therefore, the obtained patient-specific model is substantially more accurate than each sub-segmentation results.

  16. Prognostic validation of a 17-segment score derived from a 20-segment score for myocardial perfusion SPECT interpretation.

    Science.gov (United States)

    Berman, Daniel S; Abidov, Aiden; Kang, Xingping; Hayes, Sean W; Friedman, John D; Sciammarella, Maria G; Cohen, Ishac; Gerlach, James; Waechter, Parker B; Germano, Guido; Hachamovitch, Rory

    2004-01-01

    Recently, a 17-segment model of the left ventricle has been recommended as an optimally weighted approach for interpreting myocardial perfusion single photon emission computed tomography (SPECT). Methods to convert databases from previous 20- to new 17-segment data and criteria for abnormality for the 17-segment scores are needed. Initially, for derivation of the conversion algorithm, 65 patients were studied (algorithm population) (pilot group, n = 28; validation group, n = 37). Three conversion algorithms were derived: algorithm 1, which used mid, distal, and apical scores; algorithm 2, which used distal and apical scores alone; and algorithm 3, which used maximal scores of the distal septal, lateral, and apical segments in the 20-segment model for 3 corresponding segments of the 17-segment model. The prognosis population comprised 16,020 consecutive patients (mean age, 65 +/- 12 years; 41% women) who had exercise or vasodilator stress technetium 99m sestamibi myocardial perfusion SPECT and were followed up for 2.1 +/- 0.8 years. In this population, 17-segment scores were derived from 20-segment scores by use of algorithm 2, which demonstrated the best agreement with expert 17-segment reading in the algorithm population. The prognostic value of the 20- and 17-segment scores was compared by converting the respective summed scores into percent myocardium abnormal. Conversion algorithm 2 was found to be highly concordant with expert visual analysis by the 17-segment model (r = 0.982; kappa = 0.866) in the algorithm population. In the prognosis population, 456 cardiac deaths occurred during follow-up. When the conversion algorithm was applied, extent and severity of perfusion defects were nearly identical by 20- and derived 17-segment scores. The receiver operating characteristic curve areas by 20- and 17-segment perfusion scores were identical for predicting cardiac death (both 0.77 +/- 0.02, P = not significant). The optimal prognostic cutoff value for either 20

  17. Dopexamine increases internal mammary artery blood flow following coronary artery bypass grafting.

    LENUS (Irish Health Repository)

    Flynn, Michael J

    2012-02-03

    OBJECTIVE: Vasoactive agents and inotropes influence conduit-coronary blood flow following coronary artery bypass grafting (CABG). It was hypothesized that dopexamine hydrochloride, a dopamine A-1 (DA-1) and beta(2) agonist would increase conduit-coronary blood flow. A prospective randomized double blind clinical trial was carried out to test this hypothesis. DA-1 receptors have previously been localized to human left ventricle. METHODS: Twenty-six American Society of Anaesthesiology class 2-3 elective coronary artery bypass graft patients who did not require inotropic support on separation from cardiopulmonary bypass (CPB) were studied. According to a randomized allocation patients received either dopexamine (1 microg\\/kg per min) or placebo (saline) by intravenous infusion for 15 min. Immediately prior to and at 5,10 and 15 min of infusion, blood flow through the internal mammary and vein grafts (Transit time flow probes, Transonic Ltd.), heart rate, cardiac index, mean arterial pressure and pulmonary haemodynamics were noted. The data were analysed using multivariate analysis of variance. RESULTS: Low-dose dopexamine (1 microg\\/kg per min) caused a significant increase in mammary graft blood flow compared to placebo at 15 min of infusion (P=0.028, dopexamine group left internal mammary artery (LIMA) flow of 43.3+\\/-14.2 ml\\/min, placebo group LIMA flow at 26.1+\\/-16.3 ml\\/min). Dopexamine recipients demonstrated a non-significant trend to increased saphenous vein graft flow (P=0.059). Increased heart rate was the only haemodynamic change induced by dopexamine (P=0.004, dopexamine group at 85.2+\\/-9.6 beats\\/min and placebo group at 71.1+\\/-7.6 beats\\/min after 15 min of infusion). CONCLUSION: This study demonstrates that administration of dopexamine (1 microg\\/kg per min) was associated with a significant increase in internal mammary artery graft blood flow with mild increase in heart rate being the only haemodynamic change. Low-dose dopexamine may

  18. The effect of carbon dioxide therapy on composite graft survival.

    Science.gov (United States)

    Durães, Eliana Ferreira Ribeiro; Durães, Leonardo de Castro; Carneiro, Fabiana Pirani; Lino, Ruy de Souza; Sousa, João Batista de

    2013-08-01

    To investigate the effect of carboxytherapy in auricular composite grafts in rabbits. An experimental study was conducted using 20 rabbits randomly assigned to a treatment group of carboxytherapy or a control group of saline solution. In each ear, a circular graft with 1.5 cm or 2 cm of diameter was amputated and reattached. Animals underwent carbon dioxide or saline injection four times during the experiment. We analyzed clinical evolution of the animals, grafts survival, histopathology features and histomorphometry of collagen. The treated group had a significantly lower weight gain (p=0.038). Histopathology was not significantly different between groups. There was an increase in amount of collagen in 2 cm grafts submitted to carbon dioxide therapy (p=0.003). Carboxytherapy didn't influence graft survival rate for 1.5 cm grafts or 2 cm grafts (p=0.567 and p=0.777, respectively). Carbon dioxide therapy increased the amount of collagen in 2 cm grafts. CO2 was not significantly different from saline infusion on composite grafts survival, but this study suggests that there is a mechanical effect caused by distension which favored graft survival.

  19. Parametric modelling and segmentation of vertebral bodies in 3D CT and MR spine images

    International Nuclear Information System (INIS)

    Štern, Darko; Likar, Boštjan; Pernuš, Franjo; Vrtovec, Tomaž

    2011-01-01

    Accurate and objective evaluation of vertebral deformations is of significant importance in clinical diagnostics and therapy of pathological conditions affecting the spine. Although modern clinical practice is focused on three-dimensional (3D) computed tomography (CT) and magnetic resonance (MR) imaging techniques, the established methods for evaluation of vertebral deformations are limited to measuring deformations in two-dimensional (2D) x-ray images. In this paper, we propose a method for quantitative description of vertebral body deformations by efficient modelling and segmentation of vertebral bodies in 3D. The deformations are evaluated from the parameters of a 3D superquadric model, which is initialized as an elliptical cylinder and then gradually deformed by introducing transformations that yield a more detailed representation of the vertebral body shape. After modelling the vertebral body shape with 25 clinically meaningful parameters and the vertebral body pose with six rigid body parameters, the 3D model is aligned to the observed vertebral body in the 3D image. The performance of the method was evaluated on 75 vertebrae from CT and 75 vertebrae from T 2 -weighted MR spine images, extracted from the thoracolumbar part of normal and pathological spines. The results show that the proposed method can be used for 3D segmentation of vertebral bodies in CT and MR images, as the proposed 3D model is able to describe both normal and pathological vertebral body deformations. The method may therefore be used for initialization of whole vertebra segmentation or for quantitative measurement of vertebral body deformations.

  20. Application of radiation grafting techniques to prepare the high molecular weight water-soluble polymer

    International Nuclear Information System (INIS)

    Le Hai; Nguyen Quoc Hien; Nguyen Tan Man; Truong Thi Hanh; Le Huu Tu; Tran Thi Tam; Pham Thi Sam; Pham Anh Tuan; Le Dinh Lang

    2003-01-01

    The results of the study on the preparation of the high molecular weight water-soluble polymers by radiation grafting and their properties is presented as follows: 1/ by radiation grafting, the molecular weight of PVA was increased 20 times and PAM was increased only 3 times; 2/ the thermal and medium stability of poly(vinyl alcohol) grafted with acrylamide was obviously improved. (LH)

  1. Blood flow to palatal mucosal grafts in mandibular labial vestibuloplasty measured by 133Xe clearance technique

    International Nuclear Information System (INIS)

    Basa, S.; Ercan, M.T.; Aras, T.; Araz, K.

    1987-01-01

    In 11 subjects, the blood flow to alveolar and palatal mucosa was measured by intra-mucosal injection of 133 Xe. Later, mandibular labial vestibuloplasty was performed with mucosal grafts in all of them. The use of a stent was omitted. The subjects were followed by clinical observation and by blood flow measurements up to 6 weeks postoperatively. At certain intervals (3 and 10 days, 4 and 6 weeks), 133 Xe clearance in the graft was determined. Under normal conditions, the mean blood flows to the alveolar and to palatal mucosa were 53.2±12.9 and 58.3±3.5 ml/100 g/min, respectively. The difference between them was statistically insignificant (P>0.05). The graft blood flow was 13.4±3.2 and 21.7±15.0 ml/100 g/min on the 3rd and 10th days after operation. The decrease in both compared to normal values was statistically significant (P<0.001). The blood flow reached almost normal levels (46.2±16.9 ml/100 g/min) and above (63.9±9.7 ml/100 g/min; P<0.05) at 4 and 6 weeks after operation, respectively. These results were in agreement with the clinical observations. The palatal donor area healed in 3-5 weeks. The graft showed complete adaptation with the surrounding tissue and healing in 4-6 weeks. Our results also indicated that injections in the graft do not retard graft healing. (author)

  2. War, traffic and iatrogenic injuries of D3 duodenal segment

    Directory of Open Access Journals (Sweden)

    Ignjatović Dragan

    2005-01-01

    Full Text Available Background. Injuries of the duodenum at the level of aortomesenteric clamp (segment D3 are with a high incidence of death due to the development of fistula and peritonitis. In three successfully managed cases, we applied the biliary surgery method. Case reports. All three cases were with the injuries of D3 duodenal segment. The first patient suffered from the blast perforation of duodenum at the level of the aortomesenteric clamp which occurred at the 7th day after the injury. The second patient suffered from the duodenal injury caused in a traffic accident. The third patient suffered from an iatrogenic injury at the beginning of D3 duodenal segment inflicted during ureterolithotomy. The described surgical procedure included basically the suture to narrow the site of the injury, then lateroterminal anastomosis with the Roux-en-Y jejunal flexure and, finally, the placement of a silicone prosthesis starting from the duodenum through the site of injury and the Roux-en-Y out. Octreotide and the total parenteral nutrition were administered to the patients postoperatively. Conclusion. The use of the releasing silicone prosthesis in all three patients provided the repair of the site of the injury with anastomosed Reux-en-Y jejunum.

  3. Functionalization of Polymer Surfaces by Radiation-Induced Grafting for Separation of Heavy Metal Ions

    Energy Technology Data Exchange (ETDEWEB)

    Przybytniak, G; Kornacka, E M; Fuks, L; Walo, M; Lyczko, K; Mirkowski, K [Institute of Nuclear Chemistry and Technology, Dorodna 16, 03-195 Warsaw (Poland)

    2012-09-15

    The reported investigations were focused on the elucidation of the most important factors influencing radiation-induced grafting; particularly (1) the effect of radical population generated in polymeric matrix on degree of grafting, (2) parameters determined grafting and its procedure, (3) correlation between layer structure formed via copolymerization and content of monomers in the initial solution. Sorption capacity of the adsorbants was evaluated using {sup 152}Eu{sup 3+} as a marker monitoring depletion of the radioisotope from the initial solution by gamma radiometer. Electron spin resonance spectroscopy (EPR) and gas chromatography (GC) studies confirmed that yield of radiation-induced radicals increases in the following order polystyrene (PS) < polypropylene (PP) < polyethylene (PE). The same relationship was found for efficiency of radiation grafting. It was concluded that under comparable conditions the content of radicals in polymeric matrices determines grafting degree. It was found that application of the simultaneous method of grafting introduces to the grafted layers crosslinking or/and branching as well as degradation of functional groups. All these phenomena reduce access of Eu{sup 3+} to the studied sorbent therefore sorption capacity of the polyamide functionalized via pre-irradiation (indirect) method is higher than that determined for the sorbent prepared by simultaneous method of grafting. When two monomers, acrylic acid (AAc) and acrylamide (AAm) , contributed in the formation of grafted layer, their input into copolymerization was not proportional to the concentrations in the feed solution. It was confirmed that grafting of the monomers shows synergetic effect as the yield of copolymerization exceeds degree of grafting achieved for individual components. (author)

  4. Versatility of the ventral approach in bulbar urethroplasty using dorsal, ventral or dorsal plus ventral oral grafts.

    Science.gov (United States)

    Palminteri, Enzo; Berdondini, Elisa; Fusco, Ferdinando; De Nunzio, Cosimo; Giannitsas, Kostas; Shokeir, Ahmed A

    2012-06-01

    To investigate the versatility of the ventral urethrotomy approach in bulbar reconstruction with buccal mucosa (BM) grafts placed on the dorsal, ventral or dorsal plus ventral urethral surface. Between 1999 and 2008, 216 patients with bulbar strictures underwent BM graft urethroplasty using the ventral-sagittal urethrotomy approach. Of these patients, 32 (14.8%; mean stricture 3.2 cm, range 1.5-5) had a dorsal graft urethroplasty (DGU), 121 (56%; mean stricture 3.7, range 1.5-8) a ventral graft urethroplasty (VGU), and 63 (29.2%; mean stricture 3.4, range 1.5-10) a dorsal plus ventral graft urethroplasty (DVGU). The strictured urethra was opened by a ventral-sagittal urethrotomy and BM graft was inserted dorsally or ventrally or dorsal plus ventral to augment the urethral plate. The median follow-up was 37 months. The overall 5-year actuarial success rate was 91.4%. The 5-year actuarial success rates were 87.8%, 95.5% and 86.3% for the DGU, VGU and DVGU, respectively. There were no statistically significant differences among the three groups. Success rates decreased significantly only with a stricture length of >4 cm. In BM graft bulbar urethroplasties the ventral urethrotomy access is simple and versatile, allowing an intraoperative choice of dorsal, ventral or combined dorsal and ventral grafting, with comparable success rates.

  5. Focal liver lesions segmentation and classification in nonenhanced T2-weighted MRI.

    Science.gov (United States)

    Gatos, Ilias; Tsantis, Stavros; Karamesini, Maria; Spiliopoulos, Stavros; Karnabatidis, Dimitris; Hazle, John D; Kagadis, George C

    2017-07-01

    To automatically segment and classify focal liver lesions (FLLs) on nonenhanced T2-weighted magnetic resonance imaging (MRI) scans using a computer-aided diagnosis (CAD) algorithm. 71 FLLs (30 benign lesions, 19 hepatocellular carcinomas, and 22 metastases) on T2-weighted MRI scans were delineated by the proposed CAD scheme. The FLL segmentation procedure involved wavelet multiscale analysis to extract accurate edge information and mean intensity values for consecutive edges computed using horizontal and vertical analysis that were fed into the subsequent fuzzy C-means algorithm for final FLL border extraction. Texture information for each extracted lesion was derived using 42 first- and second-order textural features from grayscale value histogram, co-occurrence, and run-length matrices. Twelve morphological features were also extracted to capture any shape differentiation between classes. Feature selection was performed with stepwise multilinear regression analysis that led to a reduced feature subset. A multiclass Probabilistic Neural Network (PNN) classifier was then designed and used for lesion classification. PNN model evaluation was performed using the leave-one-out (LOO) method and receiver operating characteristic (ROC) curve analysis. The mean overlap between the automatically segmented FLLs and the manual segmentations performed by radiologists was 0.91 ± 0.12. The highest classification accuracies in the PNN model for the benign, hepatocellular carcinoma, and metastatic FLLs were 94.1%, 91.4%, and 94.1%, respectively, with sensitivity/specificity values of 90%/97.3%, 89.5%/92.2%, and 90.9%/95.6% respectively. The overall classification accuracy for the proposed system was 90.1%. Our diagnostic system using sophisticated FLL segmentation and classification algorithms is a powerful tool for routine clinical MRI-based liver evaluation and can be a supplement to contrast-enhanced MRI to prevent unnecessary invasive procedures. © 2017 American

  6. Halloysite nanotubes grafted hyperbranched (co)polymers via surface-initiated self-condensing vinyl (co)polymerization

    International Nuclear Information System (INIS)

    Mu Bin; Zhao Mingfei; Liu Peng

    2008-01-01

    Halloysite nanotubes (HNTs) grafted hyperbranched polymers were prepared by the self-condensing vinyl polymerization (SCVP) of 2-((bromoacetyl)oxy)ethyl acrylate (BAEA) and the self-condensing vinyl copolymerization of n-butyl acrylate (BA) and BAEA with BAEA as inimer (AB*) respectively, from the surfaces of the 2-bromoisobutyric acid modified halloysite nanotubes (HNTs-Br) via atom transfer radical polymerization (ATRP) technique. The halloysite nanotubes grafted hyperbranched polymer (HNTs-HP) and the halloysite nanotubes grafted hyperbranched copolymer (HNTs-HCP) were characterized by elemental analysis (EA), Fourier transform infrared (FTIR), thermogravimetric analysis (TGA), X-ray diffraction (XRD), and transmission electron microscope (TEM). The grafted hyperbranched polymers were characterized with Nuclear magnetic resonance (NMR) and the molecular ratio between the inimer AB* and BA in the grafted hyperbranched copolymers was found to be 3:2, calculated from the TGA and EA results

  7. Halloysite nanotubes grafted hyperbranched (co)polymers via surface-initiated self-condensing vinyl (co)polymerization

    Energy Technology Data Exchange (ETDEWEB)

    Mu Bin; Zhao Mingfei; Liu Peng [Lanzhou University, State Key Laboratory of Applied Organic Chemistry and Institute of Polymer Science and Engineering, College of Chemistry and Chemical Engineering (China)], E-mail: pliu@lzu.edu.cn

    2008-05-15

    Halloysite nanotubes (HNTs) grafted hyperbranched polymers were prepared by the self-condensing vinyl polymerization (SCVP) of 2-((bromoacetyl)oxy)ethyl acrylate (BAEA) and the self-condensing vinyl copolymerization of n-butyl acrylate (BA) and BAEA with BAEA as inimer (AB*) respectively, from the surfaces of the 2-bromoisobutyric acid modified halloysite nanotubes (HNTs-Br) via atom transfer radical polymerization (ATRP) technique. The halloysite nanotubes grafted hyperbranched polymer (HNTs-HP) and the halloysite nanotubes grafted hyperbranched copolymer (HNTs-HCP) were characterized by elemental analysis (EA), Fourier transform infrared (FTIR), thermogravimetric analysis (TGA), X-ray diffraction (XRD), and transmission electron microscope (TEM). The grafted hyperbranched polymers were characterized with Nuclear magnetic resonance (NMR) and the molecular ratio between the inimer AB* and BA in the grafted hyperbranched copolymers was found to be 3:2, calculated from the TGA and EA results.

  8. Channeler Ant Model: 3 D segmentation of medical images through ant colonies

    International Nuclear Information System (INIS)

    Fiorina, E.; Valzano, S.; Arteche Diaz, R.; Bosco, P.; Gargano, G.; Megna, R.; Oppedisano, C.; Massafra, A.

    2011-01-01

    In this paper the Channeler Ant Model (CAM) and some results of its application to the analysis of medical images are described. The CAM is an algorithm able to segment 3 D structures with different shapes, intensity and background. It makes use of virtual and colonies and exploits their natural capabilities to modify the environment and communicate with each other by pheromone deposition. Its performance has been validated with the segmentation of 3 D artificial objects and it has been already used successfully in lung nodules detection on Computer Tomography images. This work tries to evaluate the CAM as a candidate to solve the quantitative segmentation problem in Magnetic Resonance brain images: to evaluate the percentage of white matter, gray matter and cerebrospinal fluid in each voxel.

  9. An accurate segmentation method for volumetry of brain tumor in 3D MRI

    Science.gov (United States)

    Wang, Jiahui; Li, Qiang; Hirai, Toshinori; Katsuragawa, Shigehiko; Li, Feng; Doi, Kunio

    2008-03-01

    Accurate volumetry of brain tumors in magnetic resonance imaging (MRI) is important for evaluating the interval changes in tumor volumes during and after treatment, and also for planning of radiation therapy. In this study, an automated volumetry method for brain tumors in MRI was developed by use of a new three-dimensional (3-D) image segmentation technique. First, the central location of a tumor was identified by a radiologist, and then a volume of interest (VOI) was determined automatically. To substantially simplify tumor segmentation, we transformed the 3-D image of the tumor into a two-dimensional (2-D) image by use of a "spiral-scanning" technique, in which a radial line originating from the center of the tumor scanned the 3-D image spirally from the "north pole" to the "south pole". The voxels scanned by the radial line provided a transformed 2-D image. We employed dynamic programming to delineate an "optimal" outline of the tumor in the transformed 2-D image. We then transformed the optimal outline back into 3-D image space to determine the volume of the tumor. The volumetry method was trained and evaluated by use of 16 cases with 35 brain tumors. The agreement between tumor volumes provided by computer and a radiologist was employed as a performance metric. Our method provided relatively accurate results with a mean agreement value of 88%.

  10. Poly(ethylene-co-acrylic acid)-g-poly(ethylene glycol) graft copolymer templated synthesis of mesoporous TiO{sub 2} thin films for quasi-solid-state dye sensitized solar cells

    Energy Technology Data Exchange (ETDEWEB)

    Patel, Rajkumar; Jung, Ye Eun; Kim, Dong Jun; Kim, Sang Jin; Kim, Jong Hak, E-mail: jonghak@yonsei.ac.kr

    2014-02-03

    An amphiphilic graft copolymer, poly(ethylene-co-acrylic acid)-graft-poly(ethylene glycol) (PEAA-g-PEG), consisting of a PEAA backbone and PEG side chains was synthesized via an esterification reaction. {sup 1}H nuclear magnetic resonance and Fourier-transformed infrared analysis demonstrated esterification between carboxylic acid of PEAA and hydroxyl group of PEG. Small angle X-ray scattering results revealed that the crystalline domain spacing of PEAA increased from 11.3 to 12.8 nm upon using a more polar solvent with a higher affinity for poly(acrylic acid), while the crystalline domain spacing of PEAA disappeared with PEG grafting, indicating structural change to an amorphous state. Mesoporous TiO{sub 2} thin films were synthesized via a sol–gel reaction using PEAA-g-PEG graft copolymer as a structure-directing agent. The hydrophilically-preformed TiO{sub 2} nanoparticles were selectively confined in the hydrophilic PEG domains of the graft copolymer, and mesoporous TiO{sub 2} thin films were formed, as confirmed by scanning electron microscopy. The morphology of TiO{sub 2} films was tunable by varying the concentrations of polymer solutions and the amount of preformed TiO{sub 2}. A quasi-solid-state dye-sensitized solar cell fabricated with PEAA-g-PEG templated TiO{sub 2} film exhibited an energy conversion efficiency of 3.8% at 100 mW/cm{sup 2}, which was greater than that of commercially-available paste (2.6%) at a similar film thickness (3 μm). The improved performance was due to the larger surface area for high dye loading and organized structure with good interconnectivity. - Highlights: • Poly(ethylene-co-acrylic acid)-g-poly(ethylene glycol) (PEAA-g-PEG) graft copolymer is synthesized. • Amphiphilic PEAA-g-PEG acts as a structure directing agent. • Mesoporous TiO{sub 2} thin films are prepared by sol–gel reaction using PEAA-g-PEG template. • Efficiency of DSSC with templated TiO{sub 2} is greater than with commercial TiO{sub 2} paste.

  11. Looking beyond oral mucosa: Initial results of everted saphenous vein graft urethroplasty (eSVGU) in long anterior urethral strictures.

    Science.gov (United States)

    Akhtar, Arif; Khattar, Nikhil; Goel, Hemant; Rao, Swatantra; Tanwar, Raman; Sood, Rajeev

    2017-09-01

    To prospectively evaluate the feasibility and initial results of an everted saphenous vein graft (eSVG) as a dorsolateral onlay, in patients with long anterior urethral strictures and/or chronic tobacco users. In all, 20 patients with long anterior urethral strictures (>7 cm) and/or chronic tobacco exposed oral mucosa were included in the study. The harvested SVG was hydro-distended, detubularised, and everted. Substitution urethroplasty using an eSVG was performed using a dorsolateral onlay technique. Symptoms were assessed using the International Prostate Symptom Score (IPSS) and uroflowmetry at 1, 3 and 6 months; and voiding and retrograde urethrograms, and urethroscopy were done at 3 months. Failure was defined as failure to void, need for interventions in form of direct-vision internal urethrotomy or endodilatation. Three patients were excluded because they underwent a staged urethroplasty. In all, 17 patients underwent eSVG substitution urethroplasty. The mean (SD, range) follow-up of our patients was 17.64 (5.23, 10-26) months. The mean (SD, range) length of the strictured segment was 14 (2.5, 10-18) cm and the length of the harvested SVG was 16.3 (2.7, 12-20) cm. The mean (SD) IPSS at 1, 3 and 6 months after catheter removal was 10 (2.8), 10 (3.4) and 10 (1.4) and the quality-of-life score was 1.76 (0.5), 2.05 (1.0) and 2.05 (1.0), respectively. Postoperatively, endodilatation was required in two patients. Complete failure occurred in one patient. An eSVG, as a dorsolateral onlay graft, is a promising and prudent option for long anterior urethral strictures, especially in patients with poor oral hygiene and chronic tobacco use.

  12. Basal Cell Carcinoma in Type 2 Segmental Dariers Disease

    International Nuclear Information System (INIS)

    Robertson, L.; Sauder, M. B.

    2012-01-01

    Dariers disease (DD), also known as Keratosis Follicularis or Dariers-White disease, is a rare disorder of keratinisation. DD can present as a generalized autosomal dominant condition as well as a localized or segmental post zygotic condition (Vasquez et al., 2002). Clinical features of DD include greasy, warty papules and plaques on seborrhoeic areas, dystrophic nails, palmo-plantar pits, and papules on the dorsum of the hands and feet. Objective. We report a case of basal cell carcinoma developing in a patient with type 2 segmental DD. Conclusion. According to the current literature, Type 2 segmental disease is a rare presentation of Dariers disease with only 8 previous cases reported to date. In addition, non melanoma skin cancer (NMSC) arising from DD is rarely reported; however, there may be an association between DD and risk of carcinogenesis.

  13. Basal Cell Carcinoma in Type 2 Segmental Darier's Disease

    Directory of Open Access Journals (Sweden)

    Lynne Robertson

    2012-01-01

    Full Text Available Background. Darier's disease (DD, also known as Keratosis Follicularis or Darier-White disease, is a rare disorder of keratinization. DD can present as a generalized autosomal dominant condition as well as a localized or segmental postzygotic condition (Vázquez et al., 2002. Clinical features of DD include greasy, warty papules and plaques on seborrheic areas, dystrophic nails, palmo-plantar pits, and papules on the dorsum of the hands and feet. Objective. We report a case of basal cell carcinoma developing in a patient with type 2 segmental DD. Conclusion. According to the current literature, Type 2 segmental disease is a rare presentation of Darier's disease with only 8 previous cases reported to date. In addition, nonmelanoma skin cancer (NMSC arising from DD is rarely reported; however, there may be an association between DD and risk of carcinogenesis.

  14. Abaca/polyester nonwoven fabric functionalization for metal ion adsorbent synthesis via electron beam-induced emulsion grafting

    Science.gov (United States)

    Madrid, Jordan F.; Ueki, Yuji; Seko, Noriaki

    2013-09-01

    A metal ion adsorbent was developed from a nonwoven fabric trunk material composed of both natural and synthetic polymers. A pre-irradiation technique was used for emulsion grafting of glycidyl methacrylate (GMA) onto an electron beam irradiated abaca/polyester nonwoven fabric (APNWF). The dependence of degree of grafting (Dg), calculated from the weight of APNWF before and after grafting, on absorbed dose, reaction time and monomer concentration were evaluated. After 50 kGy irradiation with 2 MeV electron beam and subsequent 3 h reaction with an emulsion consisting of 5% GMA and 0.5% polyoxyethylene sorbitan monolaurate (Tween 20) surfactant in deionized water at 40 °C, a grafted APNWF with a Dg greater than 150% was obtained. The GMA-grafted APNWF was further modified by reaction with ethylenediamine (EDA) in isopropyl alcohol at 60 °C to introduce amine functional groups. After a 3 h reaction with 50% EDA, an amine group density of 2.7 mmole/gram adsorbent was achieved based from elemental analysis. Batch adsorption experiments were performed using Cu2+ and Ni2+ ions in aqueous solutions with initial pH of 5 at 30 °C. Results show that the adsorption capacity of the grafted adsorbent for Cu2+ is four times higher than Ni2+ ions.

  15. Automatic segmentation and 3-dimensional display based on the knowledge of head MRI images

    International Nuclear Information System (INIS)

    Suzuki, Hidetomo; Toriwaki, Jun-ichiro.

    1987-01-01

    In this paper we present a procedure which automatically extracts soft tissues, such as subcutaneous fat, brain, and cerebral ventricle, from the multislice MRI images of head region, and displays their 3-dimensional images. Segmentation of soft tissues is done by use of an iterative thresholding. In order to select the optimum threshold value automatically, we introduce a measure to evaluate the goodness of segmentation into this procedure. When the measure satisfies given conditions, iteration of thresholding terminates, and the final result of segmentation is extracted by using the current threshold value. Since this procedure can execute segmentation and calculation of the goodness measure in each slice automatically, it remarkably decreases efforts of users. Moreover, the 3-dimensional display of the segmented tissues shows that this procedure can extract the shape of each soft tissue with reasonable precision for clinical use. (author)

  16. Synthesis of Radiation Grafted Polymer Matrices for Separation and Industrial Applications

    Energy Technology Data Exchange (ETDEWEB)

    Bhardwaj, Y K; Virendra, K; Goel, N K; Sarma, K S.S.; Sabharwal, S [Radiation Technology Development Division, Bhabha Atomic Research Centre, Trombay, Mumbai-400 085 (India)

    2012-09-15

    Grafting of acrylonitrile onto non-woven porous polypropylene fibre sheet using electron beam was carried out by post-irradiation grafting. Grafting extent of {approx}125% was achieved. The grafted nitrile groups were amidoximated and studied for uranium uptake from sea water and heavy metal ions (Co{sup 2+}, Ni{sup 2+}, Mn{sup 2+}, and Cd{sup 2+}) from aqueous solutions. Adsorption and elution of adsorbed ions in suitable eluents was studied. The grafting process was upgraded to pilot scale to obtain 1x1 m{sup 2} sheets. Mutual radiation grafting technique was used for grafting of vinylbenzyltrimethyl ammonium chloride, [2- (methacryloyloxy)ethyl] trimethylammonium chloride and [2-(acryloyloxyethyl)]trimethylammonium chloride onto cotton cellulose substrate. The grafted matrices showed significantly higher water uptake and good water retention properties. The antibacterial efficacy of the grafted products was found to be a function of extent of grafting and the type of bacteria (Escherichia coli, Pseudomonas flourescens, Staphylococcus aureus and Bacillus cereus). PVBT-g-cotton was studied for its protein adsorption behaviour in continuous column process using Bovine serum albumin (BSA) as a model protein. Mutual radiation grafting technique was used to graft acrylic acid on micrometer thick micro-porous polypropylene membrane. Contact angle measurement studies showed that initial grafting as well as radiation treatment of poly(propylene) in aqueous medium and in presence of Mohr's salt enhances its affinity towards the grafting solution. The enhancement in the polar component of surface energy of treated polypropylene membrane is the primary cause of grafting enhancement. The membranes grafted to an extent of {approx}20% were found to perform comparably with the battery separator presently being used by battery industry. Acrylic acid was grafted to Teflon scrap by mutual radiation grafting technique. The grafting extent decreased with increasing dose rate and

  17. Hydroquinone and Quinone-Grafted Porous Carbons for Highly Selective CO2 Capture from Flue Gases and Natural Gas Upgrading.

    Science.gov (United States)

    Wang, Jun; Krishna, Rajamani; Yang, Jiangfeng; Deng, Shuguang

    2015-08-04

    Hydroquinone and quinone functional groups were grafted onto a hierarchical porous carbon framework via the Friedel-Crafts reaction to develop more efficient adsorbents for the selective capture and removal of carbon dioxide from flue gases and natural gas. The oxygen-doped porous carbons were characterized with scanning electron microscopy, transmission electron microscopy, X-ray powder diffraction, Fourier transform infrared spectroscopy, and Raman spectroscopy. CO2, CH4, and N2 adsorption isotherms were measured and correlated with the Langmuir model. An ideal adsorbed solution theory (IAST) selectivity for the CO2/N2 separation of 26.5 (298 K, 1 atm) was obtained on the hydroquinone-grafted carbon, which is 58.7% higher than that of the pristine porous carbon, and a CO2/CH4 selectivity value of 4.6 (298 K, 1 atm) was obtained on the quinone-grafted carbon (OAC-2), which represents a 28.4% improvement over the pristine porous carbon. The highest CO2 adsorption capacity on the oxygen-doped carbon adsorbents is 3.46 mmol g(-1) at 298 K and 1 atm. In addition, transient breakthrough simulations for CO2/CH4/N2 mixture separation were conducted to demonstrate the good separation performance of the oxygen-doped carbons in fixed bed adsorbers. Combining excellent adsorption separation properties and low heats of adsorption, the oxygen-doped carbons developed in this work appear to be very promising for flue gas treatment and natural gas upgrading.

  18. Phasing multi-segment undulators

    International Nuclear Information System (INIS)

    Chavanne, J.; Elleaume, P.; Vaerenbergh, P. Van

    1996-01-01

    An important issue in the manufacture of multi-segment undulators as a source of synchrotron radiation or as a free-electron laser (FEL) is the phasing between successive segments. The state of the art is briefly reviewed, after which a novel pure permanent magnet phasing section that is passive and does not require any current is presented. The phasing section allows the introduction of a 6 mm longitudinal gap between each segment, resulting in complete mechanical independence and reduced magnetic interaction between segments. The tolerance of the longitudinal positioning of one segment with respect to the next is found to be 2.8 times lower than that of conventional phasing. The spectrum at all gaps and useful harmonics is almost unchanged when compared with a single-segment undulator of the same total length. (au) 3 refs

  19. Comparison of mesencephalic free-floating tissue culture grafts and cell suspension grafts in the 6-hydroxydopamine-lesioned rat

    DEFF Research Database (Denmark)

    Meyer, Morten; Widmer, H R; Wagner, B

    1998-01-01

    of grafted dopaminergic neurons and to correlate that with the behavioral effects. Additional cultures and acutely prepared explants were also fixed and stored for histological investigation in order to estimate the loss of dopaminergic neurons in culture and after transplantation. Similar behavioral...... numbers of TH-immunoreactive (TH-ir) neurons in grafts of cultured tissue (775 +/- 98, mean +/- SEM) and grafts of fresh, dissociated cell suspension (806 +/- 105, mean +/- SEM). Cell counts in fresh explants, 7-day-old cultures, and grafted cultures revealed a 68.2% loss of TH-ir cells 7 days after......Ventral mesencephalon (VM) of fetal rat and human origin grown as free-floating roller-tube (FFRT) cultures can survive subsequent grafting to the adult rat striatum. To further explore the functional efficacy of such grafts, embryonic day 13 ventral mesencephalic tissue was grafted either after 7...

  20. [Clinical study of full-thickness skin graft for reconstruction of completely defect nail unit].

    Science.gov (United States)

    Li, Wen-jun; Li, Chun; Zhu, Jin; Tian, Guang-lei; Chen, Shan-lin; Tian, Wen

    2012-12-18

    To explore a reconstruction method for complete nail bed defect caused by various kinds of reasons and to retrospectively analyze the effect of application of free full-thickness skin graft for the whole nail unit repair. Between Apr. 2010 and Mar. 2012, the method of free full-thickness skin graft was done for reconstruction of the completely nail unit defect in seven cases. There were 2 male and 5 female patients; the mean age of these patients at the time of surgery was 51.9 years (range: 7 to 70 years). The preoperative diagnoses included two cases of malignant melanoma, one of chronic infection, one of squamous cell carcinoma, two of subungual pigmentation and one of junctional nevus. There were 2 thumb lesions, 3 middle and 2 index finger lesions. Nail unit defect was in the range of 1.5 cm×2 cm to 2.5 cm × 3.5 cm and full thickness skin graft was harvested from the same medial side of upper arm (3 cases), forearm cubital fossa (1 case) and contralateral side of groin region (3 cases). All the patients were followed with an average follow-up time being 10 months. All the free skin graft taken was achieved with 100% in all the 7 cases, even in those patients whose partial cortical bone had been curetted. The skin graft was often bluish initially, and superficial blisters were always noticed within 1.5 months postoperatively and the survival skin graft was smooth eventually, and skin graft was adhered to the underlying bone tightly. There was no epidermal inclusion cyst and no residual nail formation. The skin donor sites were without complications. Aesthetic appearance was assessed by the surgeons and found no unacceptable for their patients. And all the patients were satisfied with the cosmetic appearance and active range of motion of their involved fingers, who did not express a desire to undergo any further of nail reconstruction. Free full-thickness skin grafting for reconstruction of the complete nail unit defect is a simple, safe and effective

  1. Preparation of metal ion exchange resin by radiation-induced graft copolymerization

    International Nuclear Information System (INIS)

    Nakase, Yoshiaki; Akasaka, Nobuhiro.

    1982-06-01

    Radiation-induced graft copolymerization of 2-acrylamide-2-methyl propane sulfonic acid (AMPS) onto polyvinylchloride (PVC) and polyvinylidene chloride resin (PVD) was investigated in the water-acetone system and their adsorptive activities to metal ion were also examined. In the case of PVC, the degree of grafting increased with the increase of acetone content, but the adsorptive activity to metal ions (mainly lithic ion) became maximum in the system with water/acetone of 2/3. Grafted PVC prepared at about 35 0 C and at a higher concentration of AMPS showed higher adsorption activity than the other cases. In the case of PVD, a similar result was obtained with the case of PVC except the temperature dependence and effect of swelling agent. Polymerizations at temperatures of 35 and 50 0 C showed no effect on the degree of grafting, and the usage of a swelling agent was quite effective to the adsorptive activity. Glass transition temperature of the grafted copolymer was the same as that of original polymer, and their thermal stability was confirmed up to the temperature at which homopolymer of AMPS decomposed, about 180 0 C. (author)

  2. A simple and rapid method to graft hydroxyapatite on carbon nanotubes

    International Nuclear Information System (INIS)

    Neelgund, Gururaj M.; Olurode, Kehinde; Luo Zhiping; Oki, Aderemi

    2011-01-01

    Herein a simple and effective approach is introduced to functionalize single walled carbon nanotubes (SWCNTs) by in-situ grafting of hydroxyapatite (HA). The pristine SWCNTs were chemically activated through introduction of carboxylic groups on their surfaces by refluxing in the mixture of H 2 SO 4 and HNO 3 . The resulting carboxylated SWCNTs were further utilized for grafting of HA. The Fourier transform infrared and Raman spectroscopic studies demonstrated the formation of HA and its grafting over SWCNTs. The phase composition of HA and existence Ca 2+ and PO 4 3- ions were studied using X-ray diffraction and energy dispersive X-ray analyses, respectively. The surface morphology of functionalized SWCNTs was analyzed using scanning electron microscopy and transmission electron microscopy. Thermogravimetric analysis confirmed the existence of HA on SWCNTs by exhibiting different thermogram for pure HA and functionalized SWCNTs. Overall, this method produced uniform grafting of low crystalline HA on carboxylated SWCNTs with strong interfacial bonding. - Graphical abstract: A facile approach is demonstrated for effective functionalization of single walled carbon nanotubes (SWCNTs) by in-situ grafting of hydroxyapatite (HA) to improve hydrophilicity and biocompatibility of SWCNTs. This method produced uniform grafting of low crystalline HA on carboxylated SWCNTs with strong interfacial bonding. Research highlights: → This method is facile and effective to graft HA on SWCNTs. → As f-SWCNTs is a promising biomaterial to use without any further processing → This technique is economic, easy to repeat and can be optimized for mass production. → Ratio of Ca to P in f-SWCNTs was 1.65, which is near to ratio present in bone tissue.

  3. A simple and rapid method to graft hydroxyapatite on carbon nanotubes

    Energy Technology Data Exchange (ETDEWEB)

    Neelgund, Gururaj M.; Olurode, Kehinde [Department of Chemistry, Prairie View A and M University, Prairie View, TX 77446 (United States); Luo Zhiping [Microscopy and Imaging Center, Materials Science and Engineering, Texas A and M University, College Station TX 77843 (United States); Oki, Aderemi, E-mail: aroki@pvamu.edu [Department of Chemistry, Prairie View A and M University, Prairie View, TX 77446 (United States)

    2011-10-10

    Herein a simple and effective approach is introduced to functionalize single walled carbon nanotubes (SWCNTs) by in-situ grafting of hydroxyapatite (HA). The pristine SWCNTs were chemically activated through introduction of carboxylic groups on their surfaces by refluxing in the mixture of H{sub 2}SO{sub 4} and HNO{sub 3}. The resulting carboxylated SWCNTs were further utilized for grafting of HA. The Fourier transform infrared and Raman spectroscopic studies demonstrated the formation of HA and its grafting over SWCNTs. The phase composition of HA and existence Ca{sup 2+} and PO{sub 4}{sup 3-} ions were studied using X-ray diffraction and energy dispersive X-ray analyses, respectively. The surface morphology of functionalized SWCNTs was analyzed using scanning electron microscopy and transmission electron microscopy. Thermogravimetric analysis confirmed the existence of HA on SWCNTs by exhibiting different thermogram for pure HA and functionalized SWCNTs. Overall, this method produced uniform grafting of low crystalline HA on carboxylated SWCNTs with strong interfacial bonding. - Graphical abstract: A facile approach is demonstrated for effective functionalization of single walled carbon nanotubes (SWCNTs) by in-situ grafting of hydroxyapatite (HA) to improve hydrophilicity and biocompatibility of SWCNTs. This method produced uniform grafting of low crystalline HA on carboxylated SWCNTs with strong interfacial bonding. Research highlights: {yields} This method is facile and effective to graft HA on SWCNTs. {yields} As f-SWCNTs is a promising biomaterial to use without any further processing {yields} This technique is economic, easy to repeat and can be optimized for mass production. {yields} Ratio of Ca to P in f-SWCNTs was 1.65, which is near to ratio present in bone tissue.

  4. Internal fixation and muscle pedicle bone grafting in femoral neck fractures

    Directory of Open Access Journals (Sweden)

    Gupta A

    2008-01-01

    Full Text Available Background: The treatment of displaced intracapsular femoral neck fracture is still an unsolved problem. Non-union and avascular necrosis are the two main complications of this fracture, especially if patient presents late. Muscle pedicle bone grafting has been advocated to provide additional blood supply. We present analysis of our 32 cases of displaced femoral neck fracture treated by internal fixation and quadratus femoris based muscle pedicle bone grafting. Materials and Methods: Open reduction and internal fixation with muscle pedicle grafting was done in 32 patients. The age of patients varied from 14-62 years (average age 45 years with male to female ratio of 13:3. Twenty-nine fractures were more than three weeks old. All the cases were treated by Meyers′ procedure. The fracture was internally fixed after open reduction and then a muscle pedicle graft was applied. It was supplemented by cancellous bone graft in seven cases. Fixation was done by parallel cancellous lag screws ( n = 19, crossed Garden′s screws ( n = 7, parallel Asnis screws ( n = 5 and Moore′s pin ( n = 1.Quadratus femoris muscle pedicle graft was used in 32 cases. In the initial 12 cases the graft was fixed with circumferential proline sutures, but later, to provide a secure fixation, the graft was fixed with a cancellous screw ( n = 20. Postoperative full weight bearing was deferred to an average of 10 weeks. Results: Union was achieved in 26/29 (89.65% cases which could be followed for an average period of 3.4 years, (2-8.5 years with good functional results and had the ability to squat and sit cross-legged. Results were based on hip rating system given by Salvatti and Wilson. The results were excellent in 15 cases, good in four cases, fair in four cases and poor in six cases. Complications were avascular necrosis ( n = 2, transient foot drop ( n = 2, coxa-vara ( n = 1 and temporary loss of scrotal sensation ( n = 1. Conclusion: Muscle pedicle bone grafting with

  5. 3D geomarketing segmentation: A higher spatial dimension planning perspective

    DEFF Research Database (Denmark)

    Suhaibah, A.; Uznir, U.; Rahman, A. A.

    2016-01-01

    Geomarketing is a discipline which uses geographic information in the process of planning and implementation of marketing activities. It can be used in any aspect of the marketing such as price, promotion or geo targeting. The analysis of geomarketing data use a huge data pool such as location...... residential areas, topography, it also analyzes demographic information such as age, genre, annual income and lifestyle. This information can help users to develop successful promotional campaigns in order to achieve marketing goals. One of the common activities in geomarketing is market segmentation...... a combination of market segmentation based on geographic criteria and clustering algorithm for 3D geomarketing data management. The proposed approach is capable in minimizing the overlap region during market segmentation. In this paper, geomarketing in urban area is used as a case study. Based on the case study...

  6. Alveolar graft in the cleft lip and palate patient: Review of 104 cases

    Science.gov (United States)

    Tobella-Camps, María L.; Rivera-Baró, Alejandro

    2014-01-01

    Introduction: Alveolar bone grafting is a vital part of the rehabilitation of cleft patients. The factors that have been most frequently associated with the success of the graft are the age at grafting and the pre-grafting orthodontic treatment. Objectives: 1) Describe the cases of alveolar bone grafts performed at the Maxilofacial Unit of Hospital Sant Joan de Déu, Barcelona (HSJD); and 2) Analyze the success/failure of alveolar grafts and related variables. Material and Methods: Descriptive retrospective study using a sample of 104 patients who underwent a secondary alveolar graft at the Craniofacial Unit of HSJD between 1998 and 2012. The graft was done by the same surgeon in all patients using bone from the iliac crest. Results: 70% of the patients underwent the procedure before the age of 15 (median 14.45 years); 70% of the graft patients underwent pre-graft maxillary expansion. A total of 100 cases were recorded as successful (median age of 14.58 years, 68 underwent pre-graft expansion) and only 4 were recorded as failures (median age of 17.62 years, 3 underwent pre-graft expansion). We did not find statistically significant differences in age at the time of grafting or pre-surgical expansion when comparing the success and failure groups. We found the success rate of the graft to be 96.2%. Conclusions: The number of failures was too small to establish a statistically significant conclusion in our sample regarding the age at grafting and pre-grafting expansion. The use of alveolar bone grafting from the iliac crest has a very high success rate with a very low incidence of complications. Existing controversies regarding secondary bone grafting and the wide range of success rates found in the literature suggest that it is necessary to establish a specific treatment protocol that ensures the success of this procedure. Key words:Alveolar graft, cleft lip and palate, alveolar cleft, alveolar defect. PMID:24880440

  7. Attitudes to Medication after Kidney Transplantation and Their Association with Medication Adherence and Graft Survival: A 2-Year Follow-Up Study

    Directory of Open Access Journals (Sweden)

    Mirjam Tielen

    2014-01-01

    Full Text Available Background. Nonadherence to medication is a common problem after kidney transplantation. The aim of this study was to explore attitudes towards medication, adherence, and the relationship with clinical outcomes. Method. Kidney recipients participated in a Q-methodological study 6 weeks after transplantation. As a measure of medication adherence, respondents completed the Basel Assessment of Adherence to Immunosuppressive Medications Scale (BAASIS©-interview. Moreover, the intrapatient variability in the pharmacokinetics of tacrolimus was calculated, which measures stability of drug intake. Data on graft survival was retrieved from patient records up to 2 years after transplantation. Results. 113 renal transplant recipients (19–75 years old participated in the study. Results revealed three attitudes towards medication adherence—attitude 1: “confident and accurate,” attitude 2: “concerned and vigilant,” and attitude 3: “appearance oriented and assertive.” We found association of attitudes with intrapatient variability in pharmacokinetics of tacrolimus, but not with self-reported nonadherence or graft survival. However, self-reported nonadherence immediately after transplantation was associated with lower two-year graft survival. Conclusion. These preliminary findings suggest that nonadherence shortly after kidney transplantation may be a risk factor for lower graft survival in the years to follow. The attitudes to medication were not a risk factor.

  8. SYNTHESIS AND STRUCTURAL FEATURES OF NOVEL VANADIUM(II) AMIDES - X-RAY STRUCTURES OF OCTAHEDRAL [(2-C5H4N)(CH3)N]2V(TMEDA) (TMEDA=N,N,N',N'-TETRAMETHYLETHYLENEDIAMINE) AND SQUARE-PYRAMIDAL [2,5-(CH3)2C4H2N]2V(PY)3 (PY=PYRIDINE)

    NARCIS (Netherlands)

    EDEMA, JJH; GAMBAROTTA, S; MEETSMA, A; SPEK, AL; VELDMAN, N

    1991-01-01

    The reaction of trans-(TMEDA)2VCl2 (TMEDA = N,N,N',N'-tetramethylethylenediamine) with both mono- and bidentate alkali-metal amides has been investigated. Utilization of 2 equiv of bidentate amide (N segment N)-M [M = Li, Na; N segment N = 2-?? (MeN)C5H4N (1), PhNNNPh (2), 7-azaindolyl (3),

  9. Total and regional blood flows in vascularized skeletal muscle grafts in rabbits

    International Nuclear Information System (INIS)

    Burton, H.W.; Stevenson, T.R.; Dysko, R.C.; Gallagher, K.P.; Faulkner, J.A.

    1988-01-01

    The transplantation of whole skeletal muscles is a common clinical procedure. Although atypical blood flows have been reported in small free muscle grafts, the blood flow of large neurovascular-intact (NVI) and neurovascular-anastomosed (NVA) grafts have not been measured. Because the maximum specific force (N/cm 2 ) of NVI and NVA grafts is 65% that of control muscles, we hypothesized that total and regional blood flows of NVI and NVA grafts at rest and during twitch contractions are significantly lower than lower flows of control muscles. In rabbits, blood flows of control rectus femoris (RFM) muscles and NVI and NVA grafts of RFM muscles were measured by the radioactive-microsphere technique. Total blood flows in grafts were not different from the control RFM muscle values, except for a higher resting flow in NVA grafts and a lower flow at 3 Hz in NVI grafts. Minor variations in regional flows were observed. We conclude that the operative procedures of grating and repair of blood vessels affect the vascular bed of muscles minimally, and the deficits observed in grafts do not arise from inadequate perfusion

  10. Vertical augmentation of the posterior atrophic mandible by interpositional grafts in a split-mouth design: a human tomography evaluation pilot study.

    Science.gov (United States)

    Domingues, Eduardo Pinheiro; Ribeiro, Rafael Fernandes; Horta, Martinho Campolina Rebello; Manzi, Flávio Ricardo; Côsso, Maurício Greco; Zenóbio, Elton Gonçalves

    2017-10-01

    Using computed tomography, to compare vertical and volumetric bone augmentation after interposition grafting with bovine bone mineral matrix (GEISTLICH BIO-OSS ® ) or hydroxyapatite/tricalcium phosphate (STRAUMANN ® BONECERAMIC) for atrophic posterior mandible reconstruction through segmental osteotomy. Seven patients received interposition grafts in the posterior mandible for implant rehabilitation. The computed tomography cone beam images were analysed with OsiriX Imaging Software 6.5 (Pixmeo Geneva, Switzerland) in the pre-surgical period (T0), at 15 days post-surgery (T1) and at 180 days post-surgery (T2). The tomographic analysis was performed by a single trained and calibrated radiologist. Descriptive statistics and nonparametric methods were used to analyse the data. There was a significant difference in vertical and volume augmentation with both biomaterials using the technique (P  0.05) in volume change of the graft, bone volume augmentation, or augmentation of the maximum linear vertical distance between the two analysed biomaterials. The GEISTLICH BIO-OSS ® and STRAUMANN ® BONECERAMIC interposition grafts exhibited similar and sufficient dimensional stability and volume gain for short implants in the atrophic posterior mandible. © 2016 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  11. Improvement of blood compatibility of polyurethane elastomer by radiation graft copolymerization of 2-hydroxyethyl methacrylate in polymer matrix

    International Nuclear Information System (INIS)

    Li Ximing; Chen Wenming; Yuan Zhijian; Li Song; Lu Mei

    1988-01-01

    The γ-radiation induced grafting of 2-hydroxyethyl methacrylate (HEMA) onto polyurethane-elastomers (PUE) tube by preswelling technique to prepare biomedical materials with blood compatibility is studied. The graft yield can be controlled by regulating the preswelling time and temperature, or by change the irradiation dose and dose rate. After antithrombogenic test in vitro it has been confirmed that the blood compatibility of original polyurethane tube has been considerably improved by grafting

  12. Towards dense volumetric pancreas segmentation in CT using 3D fully convolutional networks

    Science.gov (United States)

    Roth, Holger; Oda, Masahiro; Shimizu, Natsuki; Oda, Hirohisa; Hayashi, Yuichiro; Kitasaka, Takayuki; Fujiwara, Michitaka; Misawa, Kazunari; Mori, Kensaku

    2018-03-01

    Pancreas segmentation in computed tomography imaging has been historically difficult for automated methods because of the large shape and size variations between patients. In this work, we describe a custom-build 3D fully convolutional network (FCN) that can process a 3D image including the whole pancreas and produce an automatic segmentation. We investigate two variations of the 3D FCN architecture; one with concatenation and one with summation skip connections to the decoder part of the network. We evaluate our methods on a dataset from a clinical trial with gastric cancer patients, including 147 contrast enhanced abdominal CT scans acquired in the portal venous phase. Using the summation architecture, we achieve an average Dice score of 89.7 +/- 3.8 (range [79.8, 94.8])% in testing, achieving the new state-of-the-art performance in pancreas segmentation on this dataset.

  13. Corneal graft reversal: Histopathologic report of two cases.

    Science.gov (United States)

    Qahtani, Abdullah A; Alkatan, Hind M

    2014-10-01

    Graft reversal is a rare cause for failed PKP. In this case report we are presenting 2 graft failure cases in which the corneal grafts were reversed unintentionally. The onset of signs of graft failure, however was variable. We have included their clinical course and the histopathologic findings of the removed corneal grafts. A total of 6 cases including ours have been reported so far. The aim of this report is to attract the attention of corneal surgeons to an additional rare cause for failed penetrating keratoplasty (PKP) which is donor graft reversal.

  14. Nanofat grafting under a split-thickness skin graft for problematic wound management.

    Science.gov (United States)

    Kemaloğlu, Cemal Alper

    2016-01-01

    Obesity and certain medical disorders make the reconstruction of skin defects challenging. Different kind of procedure can be used for these defect, besides, skin grafting is one of the most common and simplest procedure. Fat grafting and stem cells which are located in the adipose tissue have been commonly used in plastic surgery for regeneration and rejuvenation purposes. To decrease graft failure rate we performed nanofat grafting under an autologous split-thickness skin graft in our patient who had a problematic wound. The case of a 35-year-old female patient with a traumatic skin defect on her left anterior crural region is described herein. After subsequent flap reconstruction, the result was disappointing and the defect size was widened. The defect was treated with combined grafting (nanofat grafting under an autologous split-thickness skin graft). At the 6 months follow-up assessment after combined grafting, the integrity of the skin graft was good with excellent pliability. Combined grafting for problematic wounds seems to be a useful technique for cases requiring reconstruction. The potential existence of stem cells may be responsible for the successful result in our patient.

  15. High-resolution, time-resolved MRA provides superior definition of lower-extremity arterial segments compared to 2D time-of-flight imaging.

    Science.gov (United States)

    Thornton, F J; Du, J; Suleiman, S A; Dieter, R; Tefera, G; Pillai, K R; Korosec, F R; Mistretta, C A; Grist, T M

    2006-08-01

    To evaluate a novel time-resolved contrast-enhanced (CE) projection reconstruction (PR) magnetic resonance angiography (MRA) method for identifying potential bypass graft target vessels in patients with Class II-IV peripheral vascular disease. Twenty patients (M:F = 15:5, mean age = 58 years, range = 48-83 years), were recruited from routine MRA referrals. All imaging was performed on a 1.5 T MRI system with fast gradients (Signa LX; GE Healthcare, Waukesha, WI). Images were acquired with a novel technique that combined undersampled PR with a time-resolved acquisition to yield an MRA method with high temporal and spatial resolution. The method is called PR hyper time-resolved imaging of contrast kinetics (PR-hyperTRICKS). Quantitative and qualitative analyses were used to compare two-dimensional (2D) time-of-flight (TOF) and PR-hyperTRICKS in 13 arterial segments per lower extremity. Statistical analysis was performed with the Wilcoxon signed-rank test. Fifteen percent (77/517) of the vessels were scored as missing or nondiagnostic with 2D TOF, but were scored as diagnostic with PR-hyperTRICKS. Image quality was superior with PR-hyperTRICKS vs. 2D TOF (on a four-point scale, mean rank = 3.3 +/- 1.2 vs. 2.9 +/- 1.2, P < 0.0001). PR-hyperTRICKS produced images with high contrast-to-noise ratios (CNR) and high spatial and temporal resolution. 2D TOF images were of inferior quality due to moderate spatial resolution, inferior CNR, greater flow-related artifacts, and absence of temporal resolution. PR-hyperTRICKS provides superior preoperative assessment of lower limb ischemia compared to 2D TOF.

  16. Effect of bidispersity in grafted chain length on grafted chain conformations and potential of mean force between polymer grafted nanoparticles in a homopolymer matrix.

    Science.gov (United States)

    Nair, Nitish; Wentzel, Nathaniel; Jayaraman, Arthi

    2011-05-21

    In efforts to produce polymeric materials with tailored physical properties, significant interest has grown around the ability to control the spatial organization of nanoparticles in polymer nanocomposites. One way to achieve controlled particle arrangement is by grafting the nanoparticle surface with polymers that are compatible with the matrix, thus manipulating the interfacial interactions between the nanoparticles and the polymer matrix. Previous work has shown that the molecular weight of the grafted polymer, both at high grafting density and low grafting density, plays a key role in dictating the effective inter-particle interactions in a polymer matrix. At high grafting density nanoparticles disperse (aggregate) if the graft molecular weight is higher (lower) than the matrix molecular weight. At low grafting density the longer grafts can better shield the nanoparticle surface from direct particle-particle contacts than the shorter grafts and lead to the dispersion of the grafted particles in the matrix. Despite the importance of graft molecular weight, and evidence of non-trivial effects of polydispersity of chains grafted on flat surfaces, most theoretical work on polymer grafted nanoparticles has only focused on monodisperse grafted chains. In this paper, we focus on how bidispersity in grafted chain lengths affects the grafted chain conformations and inter-particle interactions in an implicit solvent and in a dense homopolymer polymer matrix. We first present the effects of bidispersity on grafted chain conformations in a single polymer grafted particle using purely Monte Carlo (MC) simulations. This is followed by calculations of the potential of mean force (PMF) between two grafted particles in a polymer matrix using a self-consistent Polymer Reference Interaction Site Model theory-Monte Carlo simulation approach. Monte Carlo simulations of a single polymer grafted particle in an implicit solvent show that in the bidisperse polymer grafted particles

  17. Laccase from Aspergillus niger: A novel tool to graft multifunctional materials of interests and their characterization.

    Science.gov (United States)

    Iqbal, Hafiz M N; Kyazze, Godfrey; Tron, Thierry; Keshavarz, Tajalli

    2018-03-01

    In the present study, we propose a green route to prepare poly(3-hydroxybutyrate) [(P(3HB)] grafted ethyl cellulose (EC) based green composites with novel characteristics through laccase-assisted grafting. P(3HB) was used as a side chain whereas, EC as a backbone material under ambient processing conditions. A novel laccase obtained from Aspergillus niger through its heterologous expression in Saccharomyces cerevisiae was used as a green catalyst for grafting purposes without the use of additional initiator and/or cross-linking agents. Subsequently, the resulting P(3HB)- g -EC composites were characterized using a range of analytical and imagining techniques. Fourier transform infrared spectroscopy (FT-IR) spectra showed an increase in the hydrogen-bonding type interactions between the side chains of P(3HB) and backbone material of EC. Evidently, X-ray diffraction (XRD) analysis revealed a decrease in the crystallinity of the P(3HB)- g -EC composites as compared to the pristine individual polymers. A homogeneous P(3HB) distribution was also achieved in case of the graft composite prepared in the presence of 2,2'-azino-bis(3-ethylbenzothiazoline-6-sulphonic acid) (ABTS) as a mediator along with laccase as compared to the composite prepared using pure laccase alone. A substantial improvement in the thermal and mechanical characteristics was observed for grafted composites up to the different extent as compared to the pristine counterparts. The hydrophobic/hydrophilic properties of the grafted composites were better than those of the pristine counterparts.

  18. Efficient 3D multi-region prostate MRI segmentation using dual optimization.

    Science.gov (United States)

    Qiu, Wu; Yuan, Jing; Ukwatta, Eranga; Sun, Yue; Rajchl, Martin; Fenster, Aaron

    2013-01-01

    Efficient and accurate extraction of the prostate, in particular its clinically meaningful sub-regions from 3D MR images, is of great interest in image-guided prostate interventions and diagnosis of prostate cancer. In this work, we propose a novel multi-region segmentation approach to simultaneously locating the boundaries of the prostate and its two major sub-regions: the central gland and the peripheral zone. The proposed method utilizes the prior knowledge of the spatial region consistency and employs a customized prostate appearance model to simultaneously segment multiple clinically meaningful regions. We solve the resulted challenging combinatorial optimization problem by means of convex relaxation, for which we introduce a novel spatially continuous flow-maximization model and demonstrate its duality to the investigated convex relaxed optimization problem with the region consistency constraint. Moreover, the proposed continuous max-flow model naturally leads to a new and efficient continuous max-flow based algorithm, which enjoys great advantages in numerics and can be readily implemented on GPUs. Experiments using 15 T2-weighted 3D prostate MR images, by inter- and intra-operator variability, demonstrate the promising performance of the proposed approach.

  19. Automatic airline baggage counting using 3D image segmentation

    Science.gov (United States)

    Yin, Deyu; Gao, Qingji; Luo, Qijun

    2017-06-01

    The baggage number needs to be checked automatically during baggage self-check-in. A fast airline baggage counting method is proposed in this paper using image segmentation based on height map which is projected by scanned baggage 3D point cloud. There is height drop in actual edge of baggage so that it can be detected by the edge detection operator. And then closed edge chains are formed from edge lines that is linked by morphological processing. Finally, the number of connected regions segmented by closed chains is taken as the baggage number. Multi-bag experiment that is performed on the condition of different placement modes proves the validity of the method.

  20. Comparative study of the monomer grafting: ethylene, acetylene, 1,3-butadiene and estyrene in the matrix of recycled polytetrafluoroethylene (PTFE)

    International Nuclear Information System (INIS)

    Ikari, Carolina T.; Rosner, Gerhardyne O.; Oliveira, Ana C.F.; Ferreto, Helio F.R.; Lima, Luiz F.C.P.; Lugao, Ademar B.; Moreira, Otavio M.

    2009-01-01

    In this study it is used the recycled polytetrafluoroethylene (PTFE), that with the gamma radiation under inert atmosphere or in presence of air, it is obtained free radicals and a posterior the monomer grafting (ethylene, acetylene, styrene or 1.3 butadiene), obtaining the copolymer polytetrafluoroethylene-g-monomer. It is studied the obtention of the polymer by two methods: by direct way, via grafting, where the polymer is irradiated in presence of monomer, and via grafting when the polymer is irradiated in absence of monomer and under inert or air. The characterization of the copolymer was performed by the techniques of infrared region absorption spectroscopy with Fourier transformation (FTIR), thermogravimetric (TGA) and derivative thermogravimetry (DTG), and percentage of mass grafting (DOG)

  1. Synthesis of electron beam grafted poly-propylene (PP) membranes for selective adsorption of uranium from sea water

    International Nuclear Information System (INIS)

    Bhardwaj, Y.K.; Virendra Kumar; Sabharwal, S.

    2001-01-01

    Graft co polymerisation of Acrylonitrile (AN) onto porous polypropylene (PP) by post irradiation technique using electron beam (EB) irradiation were studied with regards to various parameters of importance like grafting time, dose rate and horizontal stacking. Grafting of AN causes hardening as well as yellow colouration of the white flexible PP substrate sheets. Grafting reaches saturation limits of ∼130 % after grafting for 2-3 hours and no significant increase in grafting extents is seen after this period. Higher grafting levels are achieved at low dose rates. Keeping the ratio of volume of grafting solution and weight of PP substrate constant, simultaneous grafting of 10-12 PP sheets can be carried out by horizontal stacking without much variation in the grafting limits between the stacked sheets. (author)

  2. SOME TECHNIQUES IN CORNEAL GRAFTING

    African Journals Online (AJOL)

    1971-04-10

    Apr 10, 1971 ... current herpes corneae. The visual acuity was less than. 6/60. The left eye had had a central nebula since child- hood and was deemed amblyopic. Six weeks after a 7 x 0·3 mm lamellar graft in the right eye was placed, ulceration occurred in the graft junction. A total thin conjunctival flap was sutured over.

  3. Infrascrotal, perineal, femorofemoral bypass for arterial graft infection at the groin.

    Science.gov (United States)

    Illuminati, Giulo; Caliò, Francesco G; D'Urso, Antonio; Giacobbi, Daniela; Papaspyropoulos, Vassilios; Ceccanei, Gianluca

    2004-12-01

    Infrascrotal, perineal, femorofemoral bypass is an acceptable procedure for treating infection of a prosthetic arterial graft limited to a unilateral groin. A consecutive sample clinical study with a mean follow-up of 29 months. The surgical department of an academic tertiary care center and an affiliated secondary care center. Nineteen patients with a mean age of 68 years with prosthetic graft infection at the outflow anastomosis on a femoral artery at the Scarpa triangle underwent an infrascrotal, perineal, femorofemoral bypass, with excision of the graft material limited at the groin. The recipient artery was the profunda femoris artery in 12 cases, the superficial femoral in 5, and the distal common femoral artery in 2. Cumulative survival, recurrence of sepsis, primary graft patency, and limb salvage rates expressed by standard life-table analysis. Postoperative mortality rate was 5%. Cumulative (SE) survival rate was 65% (11.6%) at 3 years. Cumulative (SE) rate of freedom from recurrent sepsis was 88% (8.6%) at 3 years. Cumulative (SE) primary patency and limb salvage rates were 86% (9.4%) and 91% (7.9%), respectively, at 3 years. Femorofemoral bypass with an infrascrotal perineal approach is a valuable procedure for the treatment of femoral arterial graft infection limited at a unilateral groin.

  4. Development of sodium alginate and konkoli gum- grafted ...

    African Journals Online (AJOL)

    STORAGESEVER

    2008-05-02

    May 2, 2008 ... grafted-polyacrylamide blend membrane: optimization of grafting conditions .... medium and reduce rate of termination by the coupling of the growing ... Effect of time. The time conversion curve of the graft copolymerization ...

  5. Effect of calvarial burring on resorption of onlay cranial bone graft.

    Science.gov (United States)

    Hassanein, Aladdin H; Clune, James E; Mulliken, John B; Arany, Praveen R; Rogers, Gary F; Kulungowski, Ann M; Greene, Arin K

    2012-09-01

    Variable resorption occurs whenever calvarial bone graft is used for onlay cranioplasty. The recipient ectocortex may be burred to expose vessels and osteocytes to maximize healing. The purpose of this study was to determine whether abrading the recipient site improves the volume of onlay graft. The parietal bones of 17 rabbits were sectioned into split-thickness and full-thickness grafts. The right frontal cortex was abraded with a bur to punctate bleeding. Pairs of split-thickness (n = 48) or full-thickness (n = 20) grafts were onlayed to the burred right frontal bone and to the nonburred left frontal bone. Micro-computed tomography was used to determine graft volume immediately postoperatively and 16 weeks later. Histology, including tartrate-resistant acid phosphatase staining, was performed to quantify vascular channels and osteoclasts per high-power field 10 days postoperatively. Split-thickness graft volume decreased 58.0% when placed on the burred calvarial site, compared with grafts on the nonburred cortex (28.4%) (P = 0.01). Full-thickness grafts showed a similar trend: greater resorption (39.1%) when onlayed onto abraded calvaria compared with nonburred ectocortex (26.0%) (P = 0.11). Split-thickness graft orientation (cortical vs cancellous side in contact with the recipient site) did not affect resorption (P = 0.67). Onlay grafts placed on the burred recipient site had more vascular channels (11.8) and osteoclasts (5.7), compared with grafts over nonabraded cortex (3.4 and 4.2, respectively) (P cranial bone grafting promotes resorption, possibly by increasing vascularization and osteoclastic activity. This technique cannot be recommended.

  6. Chronic graft versus host disease and nephrotic syndrome

    Directory of Open Access Journals (Sweden)

    Samia Barbouch

    2014-01-01

    Full Text Available Disturbed kidney function is a common complication after bone marrow transplantation. Recently, attention has been given to immune-mediated glomerular damage related to graft versus host disease (GVHD. We describe a 19-year-old woman who developed membranous glomerulonephritis after bone marrow transplantation (BMT. Six months later, she developed soft palate, skin and liver lesions considered to be chronic GVHD. Fifteen months after undergoing BMT, this patient presented with nephrotic syndrome. A renal biopsy showed mem-branous glomerulonephritis associated with a focal segmental glomerulosclerosis. She was started on corticosteroid treatment with good outcome.

  7. Computer-based planning of optimal donor sites for autologous osseous grafts

    Science.gov (United States)

    Krol, Zdzislaw; Chlebiej, Michal; Zerfass, Peter; Zeilhofer, Hans-Florian U.; Sader, Robert; Mikolajczak, Pawel; Keeve, Erwin

    2002-05-01

    Bone graft surgery is often necessary for reconstruction of craniofacial defects after trauma, tumor, infection or congenital malformation. In this operative technique the removed or missing bone segment is filled with a bone graft. The mainstay of the craniofacial reconstruction rests with the replacement of the defected bone by autogeneous bone grafts. To achieve sufficient incorporation of the autograft into the host bone, precise planning and simulation of the surgical intervention is required. The major problem is to determine as accurately as possible the donor site where the graft should be dissected from and to define the shape of the desired transplant. A computer-aided method for semi-automatic selection of optimal donor sites for autografts in craniofacial reconstructive surgery has been developed. The non-automatic step of graft design and constraint setting is followed by a fully automatic procedure to find the best fitting position. In extension to preceding work, a new optimization approach based on the Levenberg-Marquardt method has been implemented and embedded into our computer-based surgical planning system. This new technique enables, once the pre-processing step has been performed, selection of the optimal donor site in time less than one minute. The method has been applied during surgery planning step in more than 20 cases. The postoperative observations have shown that functional results, such as speech and chewing ability as well as restoration of bony continuity were clearly better compared to conventionally planned operations. Moreover, in most cases the duration of the surgical interventions has been distinctly reduced.

  8. Improving Semantic Updating Method on 3d City Models Using Hybrid Semantic-Geometric 3d Segmentation Technique

    Science.gov (United States)

    Sharkawi, K.-H.; Abdul-Rahman, A.

    2013-09-01

    to LoD4. The accuracy and structural complexity of the 3D objects increases with the LoD level where LoD0 is the simplest LoD (2.5D; Digital Terrain Model (DTM) + building or roof print) while LoD4 is the most complex LoD (architectural details with interior structures). Semantic information is one of the main components in CityGML and 3D City Models, and provides important information for any analyses. However, more often than not, the semantic information is not available for the 3D city model due to the unstandardized modelling process. One of the examples is where a building is normally generated as one object (without specific feature layers such as Roof, Ground floor, Level 1, Level 2, Block A, Block B, etc). This research attempts to develop a method to improve the semantic data updating process by segmenting the 3D building into simpler parts which will make it easier for the users to select and update the semantic information. The methodology is implemented for 3D buildings in LoD2 where the buildings are generated without architectural details but with distinct roof structures. This paper also introduces hybrid semantic-geometric 3D segmentation method that deals with hierarchical segmentation of a 3D building based on its semantic value and surface characteristics, fitted by one of the predefined primitives. For future work, the segmentation method will be implemented as part of the change detection module that can detect any changes on the 3D buildings, store and retrieve semantic information of the changed structure, automatically updates the 3D models and visualize the results in a userfriendly graphical user interface (GUI).

  9. IFNy+ and IFNy- Treg subsets with stable and unstable Foxp3 expression in kidney transplant recipients with good long-term graft function.

    Science.gov (United States)

    Trojan, Karina; Unterrainer, Christian; Aly, Mostafa; Zhu, Li; Weimer, Rolf; Bulut, Nuray; Morath, Christian; Opelz, Gerhard; Daniel, Volker

    2016-10-29

    Treg are a heterogenous cell population. In the present study we attempted to identify Treg subsets that might contribute to stable and good long-term graft function. Lymphocyte and Treg subsets were studied in 136 kidney transplant recipients with good long-term graft function and in 52 healthy control individuals using eight-color-fluorescence flow cytometry. Foxp3 TSDR methylation status was investigated in enriched IFNy+ and IFNy- Treg preparations using high resolution melt analysis. Compared with healthy controls, patients showed strong associations of IFNy secreting Helios+ and Helios- Treg with Treg that co-expressed perforin and/or CTLA4 (CD152; pterm graft function possess IFNy+ and IFNy- Treg with stable and unstable Foxp3 expression in the blood. They co-express CD28, HLADR, CTLA4, CXCR3, Lselectin, TGFβ, perforin and FasL and might contribute to the establishment and maintenance of good long-term graft function. Copyright © 2016. Published by Elsevier B.V.

  10. Clinical evaluation of single-shot and readout-segmented diffusion-weighted imaging in stroke patients at 3 T

    International Nuclear Information System (INIS)

    Morelli, John; Porter, David; Ai, Fei

    2013-01-01

    Background: Diffusion-weighted imaging (DWI) magnetic resonance imaging (MRI) is most commonly performed utilizing a single-shot echo-planar imaging technique (ss-EPI). Susceptibility artifact and image blur are severe when this sequence is utilized at 3 T. Purpose: To evaluate a readout-segmented approach to DWI MR in comparison with single-shot echo planar imaging for brain MRI. Material and Methods: Eleven healthy volunteers and 14 patients with acute and early subacute infarctions underwent DWI MR examinations at 1.5 and 3T with ss-EPI and readout-segmented echo-planar (rs-EPI) DWI at equal nominal spatial resolutions. Signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) calculations were made, and two blinded readers ranked the scans in terms of high signal intensity bulk susceptibility artifact, spatial distortions, image blur, overall preference, and motion artifact. Results: SNR and CNR were greatest with rs-EPI (8.1 ± 0.2 SNR vs. 6.0 ± 0.2; P -4 at 3T). Spatial distortions were greater with single-shot (0.23 ± 0.03 at 3T; P <0.001) than with rs-EPI (0.12 ± 0.02 at 3T). Combined with blur and artifact reduction, this resulted in a qualitative preference for the readout-segmented scans overall. Conclusion: Substantial image quality improvements are possible with readout-segmented vs. single-shot EPI - the current clinical standard for DWI - regardless of field strength (1.5 or 3 T). This results in improved image quality secondary to greater real spatial resolution and reduced artifacts from susceptibility in MR imaging of the brain

  11. Radiation grafting on natural films

    Science.gov (United States)

    Lacroix, M.; Khan, R.; Senna, M.; Sharmin, N.; Salmieri, S.; Safrany, A.

    2014-01-01

    Different methods of polymer grafting using gamma irradiation are reported in the present study for the preparation of newly functionalized biodegradable films, and some important properties related to their mechanical and barrier properties are described. Biodegradable films composed of zein and poly(vinyl alcohol) (PVA) were gamma-irradiated in presence of different ratios of acrylic acid (AAc) monomer for compatibilization purpose. Resulting grafted films (zein/PVA-g-AAc) had their puncture strength (PS=37-40 N mm-1) and puncture deformation (PD=6.5-9.8 mm) improved for 30% and 50% PVA in blend, with 5% AAc under 20 kGy. Methylcellulose (MC)-based films were irradiated in the presence of 2-hydroxyethyl methacrylate (HEMA) or silane, in order to determine the effect of monomer grafting on the mechanical properties of films. It was found that grafted films (MC-g-HEMA and MC-g-silane) using 35% monomer performed higher mechanical properties with PS values of 282-296 N mm-1 and PD of 5.0-5.5 mm under 10 kGy. Compatibilized polycaprolactone (PCL)/chitosan composites were developed via grafting silane in chitosan films. Resulting trilayer grafted composite film (PCL/chitosan-g-silane/PCL) presented superior tensile strength (TS=22 MPa) via possible improvement of interfacial adhesion (PCL/chitosan) when using 25% silane under 10 kGy. Finally, MC-based films containing crystalline nanocellulose (CNC) as a filling agent were prepared and irradiated in presence of trimethylolpropane trimethacrylate (TMPTMA) as a grafted plasticizer. Grafted films (MC-g-TMPTMA) presented superior mechanical properties with a TS of 47.9 MPa and a tensile modulus (TM) of 1792 MPa, possibly due to high yield formation of radicals to promote TMPTMA grafting during irradiation. The addition of CNC led to an additional improvement of the barrier properties, with a significant 25% reduction of water vapor permeability (WVP) of grafted films.

  12. Evaluation of aortocoronary bypass graft patency by reconstructed CT image

    International Nuclear Information System (INIS)

    Kawakita, Seizaburo; Koide, Takashi; Saito, Yoshio; Yamamoto, Tadao; Iwasaki, Tadaaki

    1982-01-01

    Ten patients were examined in the period of three months from January to March 1981. The patients were operated from 1 month to 7 years before CT. A bypass to the left anterior descending artery (LAD) was grafted in 10 cases, 2 to the right coronary artery (RCA), 4 to an obtuse marginal artery (OM), and 1 to a diagonal artery. Image reconstruction was performed in 10 cases by using an image analytical computer Evaluskop. Appropriate planes for reconstruction were selected by trial and error methods upon observation of CT images. When gained picture of a graft course coincided with surgical records or angiography, the work of building images was concluded. On cross section, grafts to LAD were visualized in all 10 cases: 9 in the entire course and 1 in a proximal part of the graft. Two to RCA, 4 to OM and 1 to a diagonal were also successfully visualized. Reconstruction of graft images succeeded in 9 grafts of 6 cases. The course of a graft could be pursued from the proximal to the distal end adjacent to the cardiac chamber. The picture of a bypass to LAD was visualized in 6 of 10 grafts. Two bypass to RCA could be depicted, and 1 to OM was also found. However 3 to OM and 1 to a diagonal failed to be visualized throughout their courses in reconstructed images. I think that the causes of faillure mainly depended upon the course of the graft. When a graft was running arc-like surrounding the heart chamber, it was very difficult to depict its entire length in reconstructed images, though the graft could be detected in cross sections. These preliminary studies indicated that reconstruction of CT images had some benefits for the pursuit of graft courses. (J.P.N.)

  13. Blood flow to palatal mucosal grafts in mandibular labial vestibuloplasty measured by /sup 133/Xe clearance technique

    Energy Technology Data Exchange (ETDEWEB)

    Basa, S; Ercan, M T; Aras, T; Araz, K

    1987-01-01

    In 11 subjects, the blood flow to alveolar and palatal mucosa was measured by intra-mucosal injection of /sup 133/Xe. Later, mandibular labial vestibuloplasty was performed with mucosal grafts in all of them. The use of a stent was omitted. The subjects were followed by clinical observation and by blood flow measurements up to 6 weeks postoperatively. At certain intervals (3 and 10 days, 4 and 6 weeks), /sup 133/Xe clearance in the graft was determined. Under normal conditions, the mean blood flows to the alveolar and to palatal mucosa were 53.2+-12.9 and 58.3+-3.5 ml/100 g/min, respectively. The difference between them was statistically insignificant (P>0.05). The graft blood flow was 13.4+-3.2 and 21.7+-15.0 ml/100 g/min on the 3rd and 10th days after operation. The decrease in both compared to normal values was statistically significant (P<0.001). The blood flow reached almost normal levels (46.2+-16.9 ml/100 g/min) and above (63.9+-9.7 ml/100 g/min; P<0.05) at 4 and 6 weeks after operation, respectively. These results were in agreement with the clinical observations. The palatal donor area healed in 3-5 weeks. The graft showed complete adaptation with the surrounding tissue and healing in 4-6 weeks. Our results also indicated that injections in the graft do not retard graft healing.

  14. Flow-Through Free Fibula Osteocutaneous Flap in Reconstruction of Tibial Bone, Soft Tissue, and Main Artery Segmental Defects.

    Science.gov (United States)

    Li, Zonghuan; Yu, Aixi; Qi, Baiwen; Pan, Zhenyu; Ding, Junhui

    2017-08-01

    The aim of this report was to present the use of flow-through free fibula osteocutaneous flap for the repair of complex tibial bone, soft tissue, and main artery segmental defects. Five patients with bone, soft tissue, and segmental anterior tibial artery defects were included. The lengths of injured tibial bones ranged from 4 to 7 cm. The sizes of impaired soft tissues were between 9 × 4 and 15 × 6 cm. The lengths of defect of anterior tibial artery segments ranged from 6 to 10 cm. Two patients had distal limb perfusion problems. Flow-through free fibula osteocutaneous flap was performed for all 5 patients. Patients were followed for 12 to 18 months. All wounds healed after 1-stage operation, and all flow-through flaps survived. The distal perfusion after vascular repair was normal in all patients. Superficial necrosis of flap edge was noted in 1 case. After the local debridement and partial thickness skin graft, the flap healed uneventfully, and the surgical operation did not increase injury to the donor site. Satisfactory bone union was achieved in all patients in 2 to 4 months postoperation. Enlargement of fibula graft was observed during follow-up from 12 to 18 months. The functions of adjacent joints were recovered, and all patients were able to walk normally. Flow-through free fibula osteocutaneous flap was shown to be an effective and efficient technique for repairing composite tibial bone, soft tissue, and main artery segmental defects. This 1-stage operation should be useful in clinical practice for the treatment of complex bone, soft tissue, and vessel defects.

  15. Mutual irradiation grafting on indigenous aramid fiber-3 in diethanolamine and epichlorohydrin and its effect on interfacially reinforced epoxy composite

    Energy Technology Data Exchange (ETDEWEB)

    Xing, Lixin [School of Chemical Engineering and Technology, Harbin Institute of Technology, Harbin 150001,China (China); Department of Materials Science and Engineering, The Pennsylvania State University, University Park, PA 16802 (United States); Liu, Li, E-mail: liuli@hit.edu.cn [School of Chemical Engineering and Technology, Harbin Institute of Technology, Harbin 150001,China (China); Xie, Fei [School of Chemical Engineering and Technology, Harbin Institute of Technology, Harbin 150001,China (China); Huang, Yudong [School of Chemical Engineering and Technology, Harbin Institute of Technology, Harbin 150001,China (China); State Key Laboratory of Urban Water Resource and Environment, Harbin Institute of Technology, Harbin 150001 (China)

    2016-07-01

    Highlights: • High energy gamma rays were used to decorate the surface of aramid fiber via mutual irradiation grafting process in two medium. • The effects of different grafting medium on aramid fiber surface were investigated through SEM, AFM, XPS, wettability and adsorption measurements. • Interfacial properties of aramid reinforced polymer composites were remarkable improved after mutual irradiation. - Abstract: The surface of indigenous aramid fiber-3 (IAF3) was decorated via mutual irradiation grafting process in diethanolamine (DEA) and epichlorohydrin (ECH), respectively, with the assist of high energy gamma rays. This modification method with great permeability produced the homogeneous and ameliorative AF3 surfaces, which were observed by the scanning electron microscopy (SEM) and atom forced microscopy (AFM). Enhanced surface free energy and reduced contact angles of irradiated AF3 verified the fabulous effectiveness of mutual irradiation without seriously injured tensile strength. The composites based on epoxy resin (ER) polymer as the matrix and irradiated IAF3 grafted DEA and ECH as the reinforcement. By capitalizing on the irradiated IAF3 which has higher wettability and adsorption on resin, the irradiated IAF3-ECH/ER composites exhibit admirable interfacial mechanical performance as compared to the pristine IAF3 contained composites. The interfacial shear strength (IFSS), interlaminar shear strength (ILSS) and flexural strength of composites were remarkable improved to 86.5, 60.13 and 511 MPa respectively, from the pristine IAF3/ER composite with IFSS of 65.9 MPa, ILSS of 48.1 MPa, and flexural strength of 479 MPa.

  16. Mutual irradiation grafting on indigenous aramid fiber-3 in diethanolamine and epichlorohydrin and its effect on interfacially reinforced epoxy composite

    International Nuclear Information System (INIS)

    Xing, Lixin; Liu, Li; Xie, Fei; Huang, Yudong

    2016-01-01

    Highlights: • High energy gamma rays were used to decorate the surface of aramid fiber via mutual irradiation grafting process in two medium. • The effects of different grafting medium on aramid fiber surface were investigated through SEM, AFM, XPS, wettability and adsorption measurements. • Interfacial properties of aramid reinforced polymer composites were remarkable improved after mutual irradiation. - Abstract: The surface of indigenous aramid fiber-3 (IAF3) was decorated via mutual irradiation grafting process in diethanolamine (DEA) and epichlorohydrin (ECH), respectively, with the assist of high energy gamma rays. This modification method with great permeability produced the homogeneous and ameliorative AF3 surfaces, which were observed by the scanning electron microscopy (SEM) and atom forced microscopy (AFM). Enhanced surface free energy and reduced contact angles of irradiated AF3 verified the fabulous effectiveness of mutual irradiation without seriously injured tensile strength. The composites based on epoxy resin (ER) polymer as the matrix and irradiated IAF3 grafted DEA and ECH as the reinforcement. By capitalizing on the irradiated IAF3 which has higher wettability and adsorption on resin, the irradiated IAF3-ECH/ER composites exhibit admirable interfacial mechanical performance as compared to the pristine IAF3 contained composites. The interfacial shear strength (IFSS), interlaminar shear strength (ILSS) and flexural strength of composites were remarkable improved to 86.5, 60.13 and 511 MPa respectively, from the pristine IAF3/ER composite with IFSS of 65.9 MPa, ILSS of 48.1 MPa, and flexural strength of 479 MPa.

  17. Bronchobiliary Fistula Treated by Self-expanding ePTFE-Covered Nitinol Stent-Graft

    International Nuclear Information System (INIS)

    Gandini, Roberto; Konda, Daniel; Tisone, Giuseppe; Pipitone, Vincenzo; Anselmo, Alessandro; Simonetti, Giovanni

    2005-01-01

    A 71-year-old man, who had undergone right hepatectomy extended to the caudate lobe with terminolateral Roux-en-Y left hepatojejunostomy for a Klatskin tumor, developed bilioptysis 3 weeks postoperatively due to bronchobiliary fistula. Percutaneous transhepatic cholangiography revealed a non-dilated biliary system with contrast medium extravasation to the right subphrenic space through a resected anomalous right posterior segmental duct. After initial unsuccessful internal-external biliary drainage, the fistula was sealed with a VIATORR covered self-expanding nitinol stent-graft placed with its distal uncovered region in the hepatojejunal anastomosis and the proximal ePTFE-lined region in the left hepatic duct. A 10-month follow-up revealed no recurrence of bilioptysis and confirmed the complete exclusion of the bronchobiliary fistula

  18. Surveillance Duplex Ultrasonography of Stent Grafts for Popliteal Aneurysms.

    Science.gov (United States)

    Pineda, Danielle M; Troutman, Douglas A; Dougherty, Matthew J; Calligaro, Keith D

    2016-05-01

    Stent grafts, also known as covered stents, have become an increasingly acceptable treatment for popliteal artery aneurysms. However, endovascular exclusion confers lower primary patency compared to traditional open bypass and exclusion. The purpose of this study was to evaluate whether duplex ultrasonography (DU) can reliably diagnose failing stent grafts placed for popliteal artery aneurysms prior to occlusion. Between June 5, 2007, and March 11, 2014, 21 stent grafts (Viabahn; Gore, Flagstaff, Arizona) were placed in 19 patients for popliteal artery aneurysms. All patients had at least 1 follow-up duplex scan postoperatively. Mean follow-up was 28.9 months (9-93 months). Postoperative DU surveillance was performed in our Intersocietal Accreditation Commission noninvasive vascular laboratory at 1 week postprocedure and every 6 months thereafter. Duplex ultrasonography measured peak systolic velocities (PSVs) and ratio of adjacent PSVs (Vr) every 5 cm within the stent graft and adjacent arteries. We retrospectively classified the following factors as "abnormal DU findings": focal PSV > 300 cm/s, uniform PSVs 3.0. These DU criteria were derived from laboratory-specific data that we previously published on failing stent grafts placed for lower extremity occlusive disease. Four of the 21 stent grafts presented with symptomatic graft thrombosis within 6 months of a normal DU. Three of these 4 patients presented with rest pain and underwent thrombectomy (2) or vein bypass (1), and 1 elected for nonintervention for claudication. Our results suggest that surveillance DU using criteria established for grafts placed for occlusive disease may not be useful for predicting stent graft failure in popliteal artery aneurysms. © The Author(s) 2016.

  19. Grafting of GMA and some comonomers onto chitosan for controlled release of diclofenac sodium.

    Science.gov (United States)

    Sharma, Rajeev Kr; Lalita; Singh, Anirudh P; Chauhan, Ghanshyam S

    2014-03-01

    In order to develop pH sensitive hydrogels for controlled drug release we have graft copolymerized glycidyl methacrylate (GMA) with comonomers acrylic acid, acrylamide and acrylonitrile, onto chitosan (Ch) by using potassium persulphate (KPS) as free radical initiator in aqueous solution. The optimum percent grafting for GMA was recorded for 1g chitosan at [KPS]=25.00 × 10(-3)mol/L, [GMA]=0.756 × 10(-3)mol/L, reaction temperature=60 °C and reaction time=1h in 20 mL H2O. Binary monomers were grafted for five different concentrations at optimum grafting conditions evaluated for GMA alone onto chitosan. The graft copolymers were characterized by FTIR, XRD, TGA and SEM. The swelling properties of chitosan and graft copolymers were investigated at different pH to define their end uses in sustained release of an anti-inflammatory drug, diclofenac sodium. Percent drug release w.r.t. drug loaded in polymeric sample was studied as function of time in buffer solutions of pH 2.0 and 7.4. In vitro release data was analyzed using Fick's Law. Chitosan grafted with binary monomers, GMA-co-AAm and GMA-co-AN showed very good results for sustained release of drug at 7.4 pH. Copyright © 2014 Elsevier B.V. All rights reserved.

  20. Cartilage grafting in nasal reconstruction.

    Science.gov (United States)

    Immerman, Sara; White, W Matthew; Constantinides, Minas

    2011-02-01

    Nasal reconstruction after resection for cutaneous malignancies poses a unique challenge to facial plastic surgeons. The nose, a unique 3-D structure, not only must remain functional but also be aesthetically pleasing to patients. A complete understanding of all the layers of the nose and knowledge of available cartilage grafting material is necessary. Autogenous material, namely septal, auricular, and costal cartilage, is the most favored material in a free cartilage graft or a composite cartilage graft. All types of material have advantages and disadvantages that should guide the most appropriate selection to maximize the functional and cosmetic outcomes for patients. Copyright © 2011 Elsevier Inc. All rights reserved.