WorldWideScience

Sample records for seeds dose measurements

  1. Radiochromic film calibration for low-energy seed brachytherapy dose measurement

    Energy Technology Data Exchange (ETDEWEB)

    Morrison, Hali, E-mail: hamorris@ualberta.ca; Menon, Geetha; Sloboda, Ron S. [Department of Medical Physics, Cross Cancer Institute, Edmonton, Alberta T6G 1Z2, Canada and Department of Oncology, University of Alberta, Edmonton, Alberta T6G 2R3 (Canada)

    2014-07-15

    Purpose: Radiochromic film dosimetry is typically performed for high energy photons and moderate doses characterizing external beam radiotherapy (XRT). The purpose of this study was to investigate the accuracy of previously established film calibration procedures used in XRT when applied to low-energy, seed-based brachytherapy at higher doses, and to determine necessary modifications to achieve similar accuracy in absolute dose measurements. Methods: Gafchromic EBT3 film was used to measure radiation doses upwards of 35 Gy from 75 kVp, 200 kVp, 6 MV, and (∼28 keV) I-125 photon sources. For the latter irradiations a custom phantom was built to hold a single I-125 seed. Film pieces were scanned with an Epson 10000XL flatbed scanner and the resulting 48-bit RGB TIFF images were analyzed using both FilmQA Pro software andMATLAB. Calibration curves relating dose and optical density via a rational functional form for all three color channels at each irradiation energy were determined with and without the inclusion of uncertainties in the measured optical densities and dose values. The accuracy of calibration curve variations obtained using piecewise fitting, a reduced film measurement area for I-125 irradiation, and a reduced number of dose levels was also investigated. The energy dependence of the film lot used was also analyzed by calculating normalized optical density values. Results: Slight differences were found in the resulting calibration curves for the various fitting methods used. The accuracy of the calibration curves was found to improve at low doses and worsen at high doses when including uncertainties in optical densities and doses, which may better represent the variability that could be seen in film optical density measurements. When exposing the films to doses > 8 Gy, two-segment piecewise fitting was found to be necessary to achieve similar accuracies in absolute dose measurements as when using smaller dose ranges. When reducing the film measurement

  2. The dose distribution surrounding 192Ir and 137Cs seed sources

    International Nuclear Information System (INIS)

    Thomason, C.; Mackie, T.R.; Wisconsin Univ., Madison, WI; Lindstrom, M.J.; Higgins, P.D.

    1991-01-01

    Dose distributions in water were measured using LiF thermoluminescent dosemeters for 192 Ir seed sources with stainless steel and with platinum encapsulation to determine the effect of differing encapsulation. Dose distribution was measured for a 137 Cs seed source. In addition, dose distributions surrounding these sources were calculated using the EGS4 Monte Carlo code and were compared to measured data. The two methods are in good agreement for all three sources. Tables are given describing dose distribution surrounding each source as a function of distance and angle. Specific dose constants were also determined from results of Monte Carlo simulation. This work confirms the use of the EGS4 Monte Carlo code in modelling 192 Ir and 137 Cs seed sources to obtain brachytherapy dose distributions. (author)

  3. High-resolution 3D dose distribution measured for two low-energy x-ray brachytherapy seeds: 125I and 103Pd

    International Nuclear Information System (INIS)

    Massillon-JL, G.; Minniti, R.; Mitch, M.G.; Soares, C.G.; Hearn, R.A.

    2011-01-01

    In this work, we have investigated the 3D absorbed dose distribution around 125 I and 103 Pd low-energy photon brachytherapy seeds using a high-spatial-resolution gel scanning system to address the current difficulty in measuring absorbed dose at close distances to these sources as a consequence of high dose rate gradient. A new version of BANG-gel coupled with a small format laser CT scanner has been used. Measurements were performed with 100 μm resolution in all dimensions. In particular, radial dose function and absorbed dose rate in the plane parallel to the sources longitudinal-axis were derived at radial distances smaller than or equal to 1 cm. In addition, the energy dependence was evaluated, finding that, within measurement uncertainties, the gel response is independent of the energy for energy photon values between 20 keV and 1250 keV. We have observed that at distances larger than 1.4 mm from the source, the delivered dose is similar to predictions from published Monte Carlo calculations (MC) for the 125 I seed. For distances between 1 mm and 3 mm, differences in magnitude and shape are significant for the 103 Pd seed, where an enhancement is observed. In the enhancement region, a difference of up to 70% in the radial dose function was obtained. Such observation suggests a contribution from other radionuclides emitting beta-particles or electrons, and not considered by MC. To understand the effect, spectrometry measurements were performed. A small contribution of 102 Rh/ 102m Rh radionuclide relative to 103 Pd was observed and its importance on the absorbed dose measured at close distances to the seed is time dependent and consequently, avoids reproducible measurements. Finally, the results obtained in this work underscore the importance of using high-spatial-resolution and water-equivalent detectors for measuring absorbed dose in low-energy photon radiation fields.

  4. The dose distribution surrounding sup 192 Ir and sup 137 Cs seed sources

    Energy Technology Data Exchange (ETDEWEB)

    Thomason, C [Wisconsin Univ., Madison, WI (USA). Dept. of Medical Physics; Mackie, T R [Wisconsin Univ., Madison, WI (USA). Dept. of Medical Physics Wisconsin Univ., Madison, WI (USA). Dept. of Human Oncology; Lindstrom, M J [Wisconsin Univ., Madison, WI (USA). Biostatistics Center; Higgins, P D [Cleveland Clinic Foundation, OH (USA). Dept. of Radiation Oncology

    1991-04-01

    Dose distributions in water were measured using LiF thermoluminescent dosemeters for {sup 192}Ir seed sources with stainless steel and with platinum encapsulation to determine the effect of differing encapsulation. Dose distribution was measured for a {sup 137}Cs seed source. In addition, dose distributions surrounding these sources were calculated using the EGS4 Monte Carlo code and were compared to measured data. The two methods are in good agreement for all three sources. Tables are given describing dose distribution surrounding each source as a function of distance and angle. Specific dose constants were also determined from results of Monte Carlo simulation. This work confirms the use of the EGS4 Monte Carlo code in modelling {sup 192}Ir and {sup 137}Cs seed sources to obtain brachytherapy dose distributions. (author).

  5. Radial dose distribution of 192Ir and 137Cs seed sources

    International Nuclear Information System (INIS)

    Thomason, C.; Higgins, P.

    1989-01-01

    The radial dose distributions in water around /sup 192/ Ir seed sources with both platinum and stainless steel encapsulation have been measured using LiF thermoluminescent dosimeters (TLD) for distances of 1 to 12 cm along the perpendicular bisector of the source to determine the effect of source encapsulation. Similar measurements also have been made around a /sup 137/ Cs seed source of comparable dimensions. The data were fit to a third order polynomial to obtain an empirical equation for the radial dose factor which then can be used in dosimetry. The coefficients of this equation for each of the three sources are given. The radial dose factor of the stainless steel encapsulated /sup 192/ Ir and that of the platinum encapsulated /sup 192/ Ir agree to within 2%. The radial dose distributions measured here for /sup 192/ Ir with either type of encapsulation and for /sup 137/ Cs are indistinguishable from those of other authors when considering uncertainties involved. For clinical dosimetry based on isotropic point or line source models, any of these equations may be used without significantly affecting accuracy

  6. Seed irradiation with continuously increasing doses of thermal neutrons

    International Nuclear Information System (INIS)

    Uhlik, J.; Pfeifer, M.; Pittermann, P.

    1977-01-01

    In the 'Raman' pea cv. the biological activity of thermal neutrons was investigated after irradiation of a 780 mm column of seeds for 3000 and 4167 seconds with a flux of 5.607 x 10 9 n.cm -2 per second. For different fractions of the seed column the average density of the neutron flux was calculated. It was proved that for the described method of seed irradiation it was sufficient to determine only the dose approaching the lethal dose. If a sufficiently high column of seeds is used part of the column of seeds will be irradiated with the optimum range of doses. The advantages of the suggested method of irradiation are not only smaller time and technological requirements resulting from the need for the determination of only the critical lethal dose of radiation by means of inhibition tests performed with seedlings, but also a simpler irradiation procedure. The suggested method of irradiation is at least nine times cheaper. (author)

  7. Simulation of measurement absorbed dose on prostate brachytherapy with radius of prostate 2 cm using MCNP5 with seed implant model isoaid AdvantageTM IAPd-103A

    International Nuclear Information System (INIS)

    Poundra Setiawan; Suharyana; Riyatun

    2015-01-01

    Simulation of measurement absorbed dose on prostate brachytherapy with radius of prostate 2 cm using MCNP5 with seed implant model IsoAid Advantage TM IAPd-103A has been conducted. 103 Pd used as a radioactive source in the seed implant and it has energy gamma emission 20,8 keV with half live 16,9 days and has activity 4 mCi. The prostate cancer is modeled with spherical and it has radius 3 cm, after planting the seed implant 103 Pdover 24,4 days, prostate cancer has absorbed dose 2,172Gy. Lethal dose maximum use 103 Pd is 125 Gy and it was reached with 59 seeds. (author)

  8. Stimulation of seeds by low dose irradiation

    International Nuclear Information System (INIS)

    Lawson, Helen

    1976-05-01

    The first section of the bibliography lists materials on the stimulation of seeds by low dose irradiation, with particular reference to stimulation of germination and yield. The second section contains a small number of selected references on seed irradiation facilities. (author)

  9. Poster — Thur Eve — 42: Radiochromic film calibration for low-energy seed brachytherapy dose measurement

    Energy Technology Data Exchange (ETDEWEB)

    Morrison, H; Menon, G; Sloboda, R [Department of Medical Physics, Cross Cancer Institute, Edmonton, Alberta T6G 1Z2 (Canada); Department of Oncology, University of Alberta, Edmonton, Alberta T6G 2R3 (Canada)

    2014-08-15

    The purpose of this study was to investigate the accuracy of radiochromic film calibration procedures used in external beam radiotherapy when applied to I-125 brachytherapy sources delivering higher doses, and to determine any necessary modifications to achieve similar accuracy in absolute dose measurements. GafChromic EBT3 film was used to measure radiation doses upwards of 35 Gy from 6 MV, 75 kVp and (∼28 keV) I-125 photon sources. A custom phantom was used for the I-125 irradiations to obtain a larger film area with nearly constant dose to reduce the effects of film heterogeneities on the optical density (OD) measurements. RGB transmission images were obtained with an Epson 10000XL flatbed scanner, and calibration curves relating OD and dose using a rational function were determined for each colour channel and at each energy using a non-linear least square minimization method. Differences found between the 6 MV calibration curve and those for the lower energy sources are large enough that 6 MV beams should not be used to calibrate film for low-energy sources. However, differences between the 75 kVp and I-125 calibration curves were quite small; indicating that 75 kVp is a good choice. Compared with I-125 irradiation, this gives the advantages of lower type B uncertainties and markedly reduced irradiation time. To obtain high accuracy calibration for the dose range up to 35 Gy, two-segment piece-wise fitting was required. This yielded absolute dose measurement accuracy above 1 Gy of ∼2% for 75 kVp and ∼5% for I-125 seed exposures.

  10. Design and dosimetry of an eye plaque containing I-125 seeds: An improved dose distribution

    International Nuclear Information System (INIS)

    Detorie, N.A.; Tkacik, M.F.; Neglia, W.J.; Jenkins, D.; Shadday, J.

    1986-01-01

    To treat intraocular tumors, a temporarily implanted eye plaque, containing 24 I-125 seeds (3M model 6711), was fabricated from 0.6-mm-thick lead disk with a 1.5-cm diameter. The I-125 seeds were distributed in a particular geometric pattern to average the dose anisotropy of each individual seed. Water phantom measurements made with TLD chips (LiF) and film over the approximate depth range of 1-25 mm were compared with treatment planning computer calculations (Capintec RT-108). Data indicate that the specified geometry produces a dose distribution delivering a tumor dose of 10,000 rad to the tumor apex (7 mm) without exceeding a sclera dose (1 mm) of 40,000 rad. Information regarding fabrication, dosimetry, and radiation safety is presented

  11. Effect of Foley catheters on seed positions and urethral dose in 125I and 103Pd prostate implants

    International Nuclear Information System (INIS)

    Brezovich, Ivan A.; Pareek, Prem N.; Duan, Jun; Fiveash, John

    2001-01-01

    Purpose: To estimate the perturbation of seed position and urethral dose, subsequent to withdrawal of urethral catheters. Methods and Materials: A mathematical model based on the volume incompressibility of tissues was used to compute seed positions and doses following removal of the Foley. The model assumed that the central axis of the urethra remains stationary, and that prostate tissue and seeds move radially toward the center of the urethra to fill the void left by the catheter. Seed motion has also been measured using transrectal ultrasound. Results: Based on the computations, seeds located originally close to the urethra travel relatively large distances toward the urethra upon Foley removal, whereas seeds located further away move substantially less. This seed motion leads to higher urethral doses than shown in a standard treatment plan. Dose enhancements increase with catheter size, decrease with increasing prostate volume, are more pronounced for 103 Pd than for 125 I, and range between 3.5% and 32.4%. Postimplant dosimetry is equally affected if images are taken with urethral catheters in place, showing lower urethral doses than actually delivered. Preliminary ultrasound based measurements of seed motion agree with the theory. Conclusion: During the implantation procedure, 12 fr or smaller urethral catheters are preferable to larger diameter catheters if urine drainage is sufficient. Treatment planners should avoid planning seeds at 5 mm or closer from the urethra. Special caution is indicated in prostates having about 20 cm 3 or smaller volumes, and when 103 Pd is used. Postimplant dosimetry is susceptible to the same errors

  12. Relative biological effectiveness of 125I seeds for low-dose-rate irradiation of PANC-1

    International Nuclear Information System (INIS)

    Wang Jidong; Wang Junjie; Zhuang Hongqing; Liao Anyan; Zhao Yong

    2008-01-01

    Objective: To investigate the relative biological effectiveness(RBE) of National Model 6711 125 I seeds and the response patterns of PANC-1 exposed to 125 I seeds irradiation. Methods: PANC-1 cells in exponential growth were irradiated at initial dose rate of 2.59 cGy/h in vitro and exposed to 1, 2, 4, 6, 8 and 10 Gy. Meanwhile, the other part of cells were exposed to the same doses by 60 Co at dose rate of 2.21 Gy/min. After irradiation, the cells were stained by trypan blue to measure the cellular mortality rate and to compare the changes along with plating times of 12, 24, 48 and 72 h after 4 Gy. The colonies were counted to obtain the plating efficiencies by colony-forming assay and the cell surviving faction was calculated to plot cell survival curves, and RBE of 125 I seeds relative to 60 Co was determined. Results: The cell death rate for continuous low- dose-rate (LDR) irradiation by 125 I seeds was greater than 60 Co at the same doses above or equal to 4 Gy. After 4 Gy irradiation, the cellular mortality rates were increased with times. The difference was significant between 125 I seeds and 60 Co. The survival fractions of 125 I were lower than those of 60 Co, and the RBE of 125 I relative to 60 Co was determined to be 1.45. Conclusion: The cell-killing effects for continuous low-dose-rate (LDR) irradiation by 125 I seeds are greater than acute high-dose-rate of 60 Co. (authors)

  13. Effect of improved TLD dosimetry on the determination of dose rate constants for 125I and 103Pd brachytherapy seeds

    International Nuclear Information System (INIS)

    Rodriguez, M.; Rogers, D. W. O.

    2014-01-01

    Purpose: To more accurately account for the relative intrinsic energy dependence and relative absorbed-dose energy dependence of TLDs when used to measure dose rate constants (DRCs) for 125 I and 103 Pd brachytherapy seeds, to thereby establish revised “measured values” for all seeds and compare the revised values with Monte Carlo and consensus values. Methods: The relative absorbed-dose energy dependence, f rel , for TLDs and the phantom correction, P phant , are calculated for 125 I and 103 Pd seeds using the EGSnrc BrachyDose and DOSXYZnrc codes. The original energy dependence and phantom corrections applied to DRC measurements are replaced by calculated (f rel ) −1 and P phant values for 24 different seed models. By comparing the modified measured DRCs to the MC values, an appropriate relative intrinsic energy dependence, k bq rel , is determined. The new P phant values and relative absorbed-dose sensitivities, S AD rel , calculated as the product of (f rel ) −1 and (k bq rel ) −1 , are used to individually revise the measured DRCs for comparison with Monte Carlo calculated values and TG-43U1 or TG-43U1S1 consensus values. Results: In general, f rel is sensitive to the energy spectra and models of the brachytherapy seeds. Values may vary up to 8.4% among 125 I and 103 Pd seed models and common TLD shapes. P phant values depend primarily on the isotope used. Deduced (k bq rel ) −1 values are 1.074 ± 0.015 and 1.084 ± 0.026 for 125 I and 103 Pd seeds, respectively. For (1 mm) 3 chips, this implies an overall absorbed-dose sensitivity relative to 60 Co or 6 MV calibrations of 1.51 ± 1% and 1.47 ± 2% for 125 I and 103 Pd seeds, respectively, as opposed to the widely used value of 1.41. Values of P phant calculated here have much lower statistical uncertainties than literature values, but systematic uncertainties from density and composition uncertainties are significant. Using these revised values with the literature’s DRC measurements, the

  14. Deterministic calculations of radiation doses from brachytherapy seeds

    International Nuclear Information System (INIS)

    Reis, Sergio Carneiro dos; Vasconcelos, Vanderley de; Santos, Ana Maria Matildes dos

    2009-01-01

    Brachytherapy is used for treating certain types of cancer by inserting radioactive sources into tumours. CDTN/CNEN is developing brachytherapy seeds to be used mainly in prostate cancer treatment. Dose calculations play a very significant role in the characterization of the developed seeds. The current state-of-the-art of computation dosimetry relies on Monte Carlo methods using, for instance, MCNP codes. However, deterministic calculations have some advantages, as, for example, short computer time to find solutions. This paper presents a software developed to calculate doses in a two-dimensional space surrounding the seed, using a deterministic algorithm. The analysed seeds consist of capsules similar to IMC6711 (OncoSeed), that are commercially available. The exposure rates and absorbed doses are computed using the Sievert integral and the Meisberger third order polynomial, respectively. The software also allows the isodose visualization at the surface plan. The user can choose between four different radionuclides ( 192 Ir, 198 Au, 137 Cs and 60 Co). He also have to enter as input data: the exposure rate constant; the source activity; the active length of the source; the number of segments in which the source will be divided; the total source length; the source diameter; and the actual and effective source thickness. The computed results were benchmarked against results from literature and developed software will be used to support the characterization process of the source that is being developed at CDTN. The software was implemented using Borland Delphi in Windows environment and is an alternative to Monte Carlo based codes. (author)

  15. Effect of low gamma-ray doses and seeding rates on growth, yield and its components as well as seed quality of lentils (lens Culinaries, med.)

    International Nuclear Information System (INIS)

    Dprgham, E.A.

    1999-01-01

    To study the effect of low doses gamma-rays and seeding rates on growth, yield and its components as well as seed quality, two experiments were conducted during 1993/1994 and 1994/1995 seasons. Each experiment included treatments which were the combinations of three levels of seeding rates (45,60 and 75kg/fed.) and four doses of gamma-rays (15, 25,35 and 45(Gy). The effect of interaction between seeding rates and gamma doses on growth characters was not significant whereas there was a tendency for improvement of growth characters by increasing gamma doses up to 45 Gy. Different gamma doses caused marked increase for lintil's yield components except the number of seeds/plant while high seeding rates (60 and 75 Kg/fed) reduced significantly the number of pods/plant and number of seeds/plant. For yield, various gamma doses showed significant increase for seed straw yield as compared to the control. However, seeding rates of 60 and 75 kg/fed increased significantly seed and straw yield as compared with the seeding rate of 45 kg/fed (control)

  16. Effect of absorbed dose and storage length on electron paramagnetic resonance (EPR) signal strength in irradiated alfalfa seeds

    International Nuclear Information System (INIS)

    Li Naining

    2006-01-01

    A kind of alfalfa seeds was irradiated by 1, 2, 3, 4 and 5 kGy at a dose rate of 6.288 kGy·h -1 in a self-shielded irradiator of 137 Cs gamma rays. The EPR spectra, which were measured subsequently between 0.3401 and 0.3501 T, showed that there was a direct proportional relationship between the EPR signal strength of free radicals produced by gamma irradiation in the alfalfa seeds and absorbed dose. The first derivative EPR spectra of the alfalfa seeds were very clear and easy to identify. However, the EPR signal strength of the peak-to-peak amplitude decreased rapidly and most of them decayed beyond 50% within 3 days after the seeds were irradiated. It tended to stabilize after half a month since the seeds were irradiated. the differences of the EPR signal strength between the irradiated and unirradiated alfalfa seeds still remained. All seeds were stored at ambient temperature for more than 3 months. Therefore, using EPR spectrometry technique to measure free radicals in alfalfa seeds as a means to determine whether the seeds have been irradiated or not is feasible, relatively fast and simple. (authors)

  17. Effect of Gamma Irradiation Doses on Some Chemical Characteristics of Cotton Seed Oil

    International Nuclear Information System (INIS)

    Saleh, O.I.

    2011-01-01

    Cotton Seeds c.v. Giza 85 (Gossypium hirsutum L.) were exposed to gamma irradiation doses of 0.5, 1.0 and 1.5 kGy to improve some chemical characteristics of cotton seed oil i.e. saturated and unsaturated fatty acids, gossypol and βsitosterol that were bound oil. The presented study showed that, the saturated fatty acids; lauric, palmitic and stearic increased when the cotton seeds were exposed to gamma irradiation doses of 0.5 up to 1.5 kGy, On the other hand, arachidic acid content decreased in all the irradiated treatments compared with untreated cotton seed. The unsaturated fatty acid oleic was increased in irradiated cotton seed samples compared with untreated one, while linoleic, the major unsaturated fatty acid decreased in irradiated cotton seed oil than untreated seeds. Gossypol and βsitosterol, bound oil, in irradiated cotton seeds increased gradually with gamma irradiated doses compared with untreated control samples

  18. Low gamma radiation dose effect on germination and initial growing of black beans (Phaseolus vulgaris L.) seeds

    International Nuclear Information System (INIS)

    Jesus, Edgar F.O. de; Silva, Anderson de O. Melo; Marsico, Eliane T.

    2005-01-01

    In this work we analyze the effect of low gamma irradiation doses and low concentrations of sodium alginate on the germination and growing of black beans seeds. The seeds were obtained from an organic farmer at Nova Friburgo, Rio de Janeiro State. The seeds were submitted to radiation doses between 0 and 150 Gy with a Cobalt 60 source in a Gammacell Excel 220 Nordion Irradiator with a dose rate of 70 Gy/min. After germination the seeds were left to grow three weeks on a hydroponics system. The system used was the water culture with nutritive solution that was supplemented with the nutritional needs for plant grows. We also tested the influence of the sodium alginate on the plant grows. A 4% solution of sodium alginate in distilled water was irradiated with 120 kGy gamma ray dose. Concentrations of sodium alginate irradiated and non-irradiated varying from 50 to 500 μg/g were used in the hydroponics' solution. After three weeks the mass and the height of the plant were measured. Statistic analyses of he result with the SAS program show that there was no significant difference between the height and mass of seeds submitted different doses, but irradiated solution of sodium alginate with concentration of 400 and 500 μg/g present a significant difference on plant grow. (author)

  19. Effect of low doses gamma irradiation on seed, bulblets and bulbs of onion

    International Nuclear Information System (INIS)

    Al-Oudat, Mohammad

    1991-10-01

    Presowing seed irradiation has been reported as a useful application of radiation in agriculture to stimulate growth and increase the yield of certain crops. To the best of our knowledge the feasibility of this treatment has not yet been tested on onion in Syria. The effect of low doses gamma irradiation on onion seeds, bulblets and bulbs of two local varieties, red and white, was studied during three consecutive seasons (1986 - 1988). Air dried seeds were irradiated by gamma rays from 137 Cs source. Five, 10, 15, 20 and 30 GY, were applied at dose rate of 9.8 Gy/min. The irradiation of onion bulblets and bulbs were carried out with gamma-rays from 60 Co source at a dose rate of 0.5 Gy/min. using 1, 2, 3, 4 and 5 Gy. Within 7 - 10 days after irradiation, both controlled and irradiated seeds, bulblets and bulbs were sown in the field in complete randomized block design with 4 replicates. Irradiation of seeds with doses of 5, 10 and 15 Gy led to highly significant increases in bulblets yield in the three seasons. The increases ranged from 14.5 to 22.1 for red variety and from 16.2 to 22.3 for white variety. The irradiation of bulblets with 1 and 2 Gy increase significantly the yield of bulbs by 21.6 - 26.0% for red variety and 21.6 - 24.4% for white variety. A considerable increase in seed yield was obtained after irradiation of bulbs with 1 and 2 Gy doses. The average increment was about 21.0% for both varieties. Large scale application were performed in 1989 and 1990 using doses of 10 Gy for seeds and 1 Gy for bulblets and bulbs. A considerable increase in the yield was obtained. The average percentage increment was 16.9% and 23.3% for seeds, 18.6 and 20.9% for bulblets, 24.8 and 27.3% for bulbs, for red and white varieties respectively. Therefore, presowing irradiation of seeds, bulblets and bulbs of onion with low doses of gamma-rays (5 - 15 Gy for seeds and 1 - 2 Gy for bulblets and bulbs) can be of practical application resulting in improvement of yield of

  20. The effects of different nitrogen doses on herbage and seed yields of ...

    African Journals Online (AJOL)

    The effects of different nitrogen doses on herbage and seed yields of annual ... 250, 270 and 290 kg ha-1) of and some agricultural characteristics of annual ryegrass cv. ... doses are observed to be important for all properties of herbage yield and ... It was obtained for the seed production that the highest number of tiller (626 ...

  1. I-125 seed dose estimates in heterogeneous phantom

    International Nuclear Information System (INIS)

    Branco, Isabela S.L.; Antunes, Paula C.G.; Cavalieri, Tassio A.; Moura, Eduardo S.; Zeituni, Carlos A.; Yoriyaz, Helio

    2015-01-01

    Brachytherapy plays an important role in the healing process involving tumors in a variety of diseases. Several studies are currently conducted to examine the heterogeneity effects of different tissues and organs in brachytherapy clinical situations and a great effort has been made to incorporate new methodologies to estimate doses with greater accuracy. The objective of this study is to contribute to the assessment of heterogeneous effects on dose due to I-125 brachytherapy source in the presence of different materials with different densities and chemical compositions. The study was performed in heterogeneous phantoms using materials that simulate human tissues. Among these is quoted: breast, fat, muscle, lungs (exhaled and inhaled) and bones with different densities. Monte Carlo simulations for dose calculation in these phantoms were held and subsequently validated. The model 6711 I-125 seed was considered because it is widely used as a brachytherapy permanent implant and the one used in clinics and hospitals in Brazil. Thermoluminescent dosimeters TLD-700 (LiF: Mg, Ti) were simulated for dose assess. Several tissue configurations and positioning of I-125 sources were studied by simulations for future dose measurements. The methodology of this study so far shall be suitable for accurate dosimetric evaluation for different types of brachytherapy treatments, contributing to brachytherapy planning systems complementation allowing a better assessment of the dose actually delivered to the patient. (author)

  2. I-125 seed dose estimates in heterogeneous phantom

    Energy Technology Data Exchange (ETDEWEB)

    Branco, Isabela S.L.; Antunes, Paula C.G.; Cavalieri, Tassio A.; Moura, Eduardo S.; Zeituni, Carlos A.; Yoriyaz, Helio, E-mail: isabela.slbranco@gmail.com [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), Sao Paulo, SP (Brazil)

    2015-07-01

    Brachytherapy plays an important role in the healing process involving tumors in a variety of diseases. Several studies are currently conducted to examine the heterogeneity effects of different tissues and organs in brachytherapy clinical situations and a great effort has been made to incorporate new methodologies to estimate doses with greater accuracy. The objective of this study is to contribute to the assessment of heterogeneous effects on dose due to I-125 brachytherapy source in the presence of different materials with different densities and chemical compositions. The study was performed in heterogeneous phantoms using materials that simulate human tissues. Among these is quoted: breast, fat, muscle, lungs (exhaled and inhaled) and bones with different densities. Monte Carlo simulations for dose calculation in these phantoms were held and subsequently validated. The model 6711 I-125 seed was considered because it is widely used as a brachytherapy permanent implant and the one used in clinics and hospitals in Brazil. Thermoluminescent dosimeters TLD-700 (LiF: Mg, Ti) were simulated for dose assess. Several tissue configurations and positioning of I-125 sources were studied by simulations for future dose measurements. The methodology of this study so far shall be suitable for accurate dosimetric evaluation for different types of brachytherapy treatments, contributing to brachytherapy planning systems complementation allowing a better assessment of the dose actually delivered to the patient. (author)

  3. Effects of gold and silver backings on the dose rate around an 125I seed

    International Nuclear Information System (INIS)

    Cygler, J.; Szanto, J.; Soubra, M.; Rogers, D.W.

    1990-01-01

    Measurements of the effect of either gold or silver backing on the dose rate around an 125I seed were performed using a Therados RFA7 dosimetry system and a small diode detector which was 2.5 mm in diameter and 0.06 mm thick. It was found that the presence of the gold or silver backing modifies the diode response on the side of the 125I seed away from the backing. The effect depends on the backing material and the distance from the seed. There is a small increase close to the gold backing but a decrease further away. This decrease at distances greater than 10 mm from the seed is uniformly 10%, the same as found when the seed is backed by air. There is an increase of up to 25% observed with silver backing the seed and this increase remains significant more than 30 mm from the seed. When the response increases, the results are hard to interpret quantitatively because of variations in the diode response per unit dose with photon energy and extreme sensitivity to geometric changes. Nonetheless, except for the increase at close distances with the gold, the results are in agreement with EGS4 Monte Carlo photon transport simulations which are for a simplified geometry and account for x-ray fluorescence from the K-shell. Furthermore, the increase in the gold-backed case is qualitatively explained by Williamson's Monte Carlo calculations which take into account the L-shell fluorescent x-rays from gold

  4. Biologically effective dose (BED) for interstitial seed implants containing a mixture of radionuclides with different half-lives

    International Nuclear Information System (INIS)

    Chen Zhe; Nath, Ravinder

    2003-01-01

    Purpose: To develop a tool for evaluating interstitial seed implants that contain a mixture of radionuclides with different half-lives and to demonstrate its utility by examining the clinical implications of prescribing to an isodose surface for such an implant. Methods and Materials: A linear-quadratic model for continuous low dose rate irradiation was developed for permanent implants containing a mixture of radionuclides. Using a generalized equation for the biologically effective dose (BED), the effects of cell proliferation and sublethal damage repair were examined systematically for implants containing a mixture of radionuclides. A head-and-neck permanent seed implant that contained a mixture of 125 I and 103 Pd seeds was used to demonstrate the utility of the generalized BED. Results: An equation of BED for implants containing a mixture of radionuclides with different half-lives was obtained. In such an implant, the effective cell kill was shown to depend strongly on the relative dose contributions from each radionuclide type; dose delivered by radionuclides with shorter half-life always resulted in more cell kill for any given sublethal damage repair and cell proliferation rates. Application of the BED formula to an implant containing a mixture of 125 I and 103 Pd seeds demonstrates that the conventional dose prescription to an isodose surface is not unique for such an implant. When the prescription dose was based on existing clinical experience of using 125 I seeds alone, mixing 103 Pd seeds with 125 I seeds would increase the cell kill. On the other hand, if the prescription dose were based on existing clinical experience of using 103 Pd seeds alone, mixing 125 I seeds with 103 Pd seeds in the same implant would create radiobiologically 'cold' spots (i.e., an increase in cell survival) at locations where a major portion of the prescription dose is contributed by the 125 I seeds. For fast-growing tumors, these 'cold' spots can become significant

  5. Development of measurement method using TLD for workers occupation personally exposed to 125I seed source in the implant

    International Nuclear Information System (INIS)

    Luo Suming; He Zhijian; Yuan Jilong; Yue Baorong; Wei Kedao

    2011-01-01

    Objective: To explore the method for measuring and calculating both absorbed dose and effective dose received in organ and tissues of occupational workers by using TLDs for the implantation of 125 I seed sources. Methods The experiments with 60 Co γ-rays were carried out for the stability. A group of TLD chips was exposed to 125 I seed sources to establish standard dose curve for air kerma. During the 125 I seed implantation, the TLD chips were pasted to 13 locations like thyroid inside and outside the lead aprons worn by occupational workers to measure average absorbed dose and calculate the absorbed doses and effective to organs and tissues. Results: For 3 cases of prostate cancers with implantation of 125 I seeds, the worker's organs and tissues received the absorbed dose 0.02 -3.80 μ Gy and effective dose 0.06- 1.81 μSv outside lead aprons and the highest absorbed dose 2.35 μ Gy and effective 0.02 μSv inside lead aprons, respectively, with more than 65.9% of rays shielded. For 3 cases of brain cancers with implantation of 125 I seeds, the workers received the absorbed dose 0.23 - 11.31 μGy and effective dose 0.88-4.07 μSv outside lead aprons and the highest absorbed dose 2.22 μ Gy and effective dose 0.09 μSv inside lead aprons, respectively, with more than 54.5% of rays shielded. For 3 cases of lung cancers with implantation of 125 I seeds, the workers received the absorbed dose 0.03 - 14.78 μGy and effective dose 0.35 -7.59 μSv outside lead aprons and the highest absorbed dose 4.09 μGy and effective 0.22 μSv inside lead aprons, respectively, with more than 58.4% of rays shielded. For 2 cases of mediastinum cancers with implantation of 125 Iseeds, the workers received the absorbed dose 0.06 - 74.91 μGy and effective dose 0.83-17.96 μSv outside lead aprons and the highest absorbed dose 10.29 μGy and effective 0.5 μSv inside lead aprons, respectively, with more than 85% of rays shielded. For one case of ovary cancer with implantation of 125

  6. Perennial soybean seeds coated with high doses of boron and zinc ...

    African Journals Online (AJOL)

    The objective of this work was to study combinations of high doses of boron (B) and zinc (Zn) in the recoating of perennial soybean seeds, in order to provide these nutrients to the future plants. The physical, physiological and nutritional characteristics of the coated seeds and initial development of plants in a greenhouse ...

  7. Effects of chronic exposure of seeds and seeds and seedlings of Arabidopsis Thaliana by low doses of γ-radiation on plant growth and development

    International Nuclear Information System (INIS)

    Litvinov, S.V.

    2013-01-01

    Article presents the results of research on the effect of chronic γ-irradiation in small doses on A. Thaliana seedlings and seeds growth and development. Exposure rate for the seeds was 0,45 mGy/h (total absorbed dose 30 cSv) and 0,18 mGy/h for seedlings (total absorbed dose 3 cSv). Statistically significant differences in the germination capacity, in the time of primary leaf rosette formation, in the hypocotyl length were revealed between irradiated and control seedlings. Plants from irradiated seeds differed by the higher growth rate of stem, they flowered and fruited earlier, but they also characterized on average shorter vegetative cycle in comparison with control plants. In our experiments it is shown significant impact of chronic low doses of γ-irradiation of seeds and seedlings on the ontogeny in A. Thaliana and on the parameters that reflect the growth and development of the irradiated plants

  8. Respiration of seed lobes after γ-irradiation of seeds with stimulating doses

    International Nuclear Information System (INIS)

    Vagabova, M.Eh.

    1975-01-01

    Air-dry black bean, mustard, castor-oil plant and maize seeds were exposed to caesium-137 gamma rays. Are the radiation doses used during the early stages of development the process of respiration in the cotyledons proved to be stimulated. As the author points out, this increases the energy supply to the developing embryo and contributes to the general mechanisms involved in the radiation stimulation of plant development. (V.A.P.)

  9. Low gamma radiation dose effect on germination and initial growing of black beans (Phaseolus vulgaris L.) seeds; Efeito de baixas doses de radiacao gama na germinacao de sementes de feijao (Phaseolus vulgaris L.)

    Energy Technology Data Exchange (ETDEWEB)

    Jesus, Edgar F.O. de; Silva, Anderson de O. Melo [Universidade Federal, Rio de Janeiro, RJ (Brazil). Coordenacao dos Programas de Pos-graduacao de Engenharia. Lab. de Instrumentacao Nuclear]. E-mail: edgar@lin.ufrj.br; Marsico, Eliane T. [Universidade Federal Fluminense, Niteroi, RJ (Brazil). Faculdade de Veterinaria. Dept. de Tecnologia de Alimentos]. E-mail: elianee@vm.uff.br

    2005-07-01

    In this work we analyze the effect of low gamma irradiation doses and low concentrations of sodium alginate on the germination and growing of black beans seeds. The seeds were obtained from an organic farmer at Nova Friburgo, Rio de Janeiro State. The seeds were submitted to radiation doses between 0 and 150 Gy with a Cobalt 60 source in a Gammacell Excel 220 Nordion Irradiator with a dose rate of 70 Gy/min. After germination the seeds were left to grow three weeks on a hydroponics system. The system used was the water culture with nutritive solution that was supplemented with the nutritional needs for plant grows. We also tested the influence of the sodium alginate on the plant grows. A 4% solution of sodium alginate in distilled water was irradiated with 120 kGy gamma ray dose. Concentrations of sodium alginate irradiated and non-irradiated varying from 50 to 500 {mu}g/g were used in the hydroponics' solution. After three weeks the mass and the height of the plant were measured. Statistic analyses of he result with the SAS program show that there was no significant difference between the height and mass of seeds submitted different doses, but irradiated solution of sodium alginate with concentration of 400 and 500 {mu}g/g present a significant difference on plant grow. (author)

  10. Dose characterization of the new Bebig IsoSeed'' (registered) I25.S17 using polymer gel and MRI

    Energy Technology Data Exchange (ETDEWEB)

    Pantelis, Evaggelos [Nuclear and Particle Physics Section, Physics Department, University of Athens, Panepistimioupolis, Ilisia, 157 71 Athens (Greece)]. E-mail: vpantelis@phys.uoa.gr; Baltas, Dimos [Nuclear and Particle Physics Section, Physics Department, University of Athens, Panepistimioupolis, Ilisia, 157 71 Athens (Greece): Department of Medical Physics and Engineering, Strahlenklinik, Klinikum Offenbach, 63069 Offenbach (Germany); Georgiou, Evaggelos [Medical Physics Department, University of Athens, 75 Mikras Asias, 115 27 Athens (Greece); Karaiskos, Pantelis [Medical Physics Department, University of Athens, 75 Mikras Asias, 115 27 Athens (Greece): Medical Physics Department, Hygeia Hospital, Kiffisias Avenue and 4 Erythrou Stavrou, Marousi, 151 23 Athens (Greece); Lymperopoulou, Georgia [Nuclear and Particle Physics Section, Physics Department, University of Athens, Panepistimioupolis, Ilisia, 157 71 Athens (Greece); Papagiannis, Panagiotis [Nuclear and Particle Physics Section, Physics Department, University of Athens, Panepistimioupolis, Ilisia, 157 71 Athens (Greece); Sakelliou, Loukas [Nuclear and Particle Physics Section, Physics Department, University of Athens, Panepistimioupolis, Ilisia, 157 71 Athens (Greece); Seimenis, Ioannis [Philips Hellas Medical Systems, 44 Kifissias Ave., Maroussi 151 25, Athens (Greece); Stilliaris, Efstathios [Nuclear and Particle Physics Section, Physics Department, University of Athens, Panepistimioupolis, Ilisia, 157 71 Athens (Greece): Institute of Accelerating Systems and Applications (IASA), P.O. Box 17214, GR-10024, Athens (Greece)

    2006-12-20

    A new, molybdenum core, {sup 125}I interstitial brachytherapy seed is marketed by Bebig GmbH (IsoSeed'' (registered) I25.S17) and our group has performed its Dosimetric characterization using Monte Carlo (MC) simulation and Thermoluminescence dosimetry (TLD) as recommended by the AAPM TG-43U1 prior to the clinical implementation of new low-energy seeds. This work presents the results of a supplementary experimental dosimetry study performed using PABIG polymer gel and Magnetic Resonance Imaging (MRI). One new I25.S17 seed and a commercially available, gold core, Bebig IsoSeed'' (registered) I25.S06 {sup 125}I seed were positioned at two different locations in a vial filled with water equivalent, PABIG-polymer gel. The gel with the sources in place was MR scanned in 3D at various time intervals after seed placement using a time efficient, 3D, dual echo Turbo Spin Echo pulse sequence. The consensus dosimetry parameters published in the TG-43U1 for the I25.S06 seed were used to derive the gel response calibration curve for each scanning session. The calibration data were then used to provide dosimetry results for the new I25.S17 seed. Experimental results for the new seed in the form of dose distributions as well as dosimetric quantities in the prevalent TG-43 dosimetric formalism were found to be in close agreement with corresponding MC and TLD results. This finding suggests that the polymer gel-MRI method could at least play a supplementary role to TLD dosimetry in the dose characterization of low energy/low dose rate brachytherapy sources, especially in view of its potential for measurements with a fine spatial resolution down to short distances which are inhibitory to conventional experimental techniques.

  11. Effects of cobalt-60 low doses radiation on beam, rice and radish seeds

    International Nuclear Information System (INIS)

    Kikuchi, O.K.

    1987-01-01

    The effects of cobalt-60 gamma radiation on seeds of bean (Phaseolus vulgaris L.), rice (Oryza sativa L.) and radish (Raphanus sativus L.) were studied. Bean and rice seeds were irradiated with 3.5 and 7.7 Gy (32 Gy/h). There was an apparent acceleration on rice seed germination with 3.5 Gy when they were stored for 6 days after irradiation, but the same dose caused a delay when the store time was 1 day. Bean seeds germination was not modified by 3.5 and 7.7 Gy, but the fresh and dry weight of young plants showed an increase, mainly due the major quantity of water in the embryonic axis. Bean seeds were irradiated with 0.5 and 2.0 Gy (30 Gy/h). Seeds germination showed a slight delay irradiating with 0.5 Gy, while height, fresh and dry weight and primary leaves area of the young plants as well as number of nodes, leaves, flowers, beans and seeds were not modified after irradiation with 0.5 and 2.0 Gy. Radish seeds irradiated with 10 and 30 Gy at dose rates of 4.5, 22.5 and 45.0 Gy/h showed a germination delay and fresh and dry weight values for young plants leaves lower than control. Roots of totally developed plants showed no modifications in weight, volume, mean diameter, lenght and in the amount of soluble reducing sugar. (author)

  12. Low doses of gamma radiation in soybean

    International Nuclear Information System (INIS)

    Franco, José G.; Franco, Suely S.H.; Villavicencio, Anna L.C.; Arthur, Valter; Arthur, Paula B.; Franco, Caio H.

    2017-01-01

    The degree of radiosensitivity depends mostly on the species, the stage of the embryo at irradiation, the doses employed and the criteria used to measure the effect. One of the most common criteria to evaluate radiosensitivity in seeds is to measure the average plant production. Dry soya seeds were exposed to low doses of gamma radiation from source of Cobalt-60, type Gammecell-220, at 0.210 kGy dose rate. In order to study stimulation effects of radiation on germination, plant growth and production. A treatment with four radiation doses was applied as follows: 0 (control); 12.5; 25.0 and 50.0 Gy. Seed germination and harvested of number of seeds and total production were assessed to identify occurrence of stimulation. Soya seeds number and plants were handled as for usual seed production in Brazil. The low doses of gamma radiation in the seeds that stimulate the production were the doses of 12.5 and 50.0 Gy. The results show that the use of low doses of gamma radiation can stimulate germination and plant production. (author)

  13. Low doses of gamma radiation in soybean

    Energy Technology Data Exchange (ETDEWEB)

    Franco, José G.; Franco, Suely S.H.; Villavicencio, Anna L.C., E-mail: zegilmar60@gmail.com, E-mail: gilmita@uol.com.br, E-mail: villavic@ipen.br [Instituto de Pesquisas Energéticas e Nucleares (IPEN/CNEN-SP), São Paulo, SP (Brazil); Arthur, Valter; Arthur, Paula B., E-mail: arthur@cena.usp.br [Centro de Energia Nuclear na Agricultura (CENA/USP), Piracicaba, SP (Brazil); Franco, Caio H. [Universidade Federal de São Paulo (UNIFESP), SP (Brazil). Departamento de Microbiologia, Imunologia e Parasitologia

    2017-07-01

    The degree of radiosensitivity depends mostly on the species, the stage of the embryo at irradiation, the doses employed and the criteria used to measure the effect. One of the most common criteria to evaluate radiosensitivity in seeds is to measure the average plant production. Dry soya seeds were exposed to low doses of gamma radiation from source of Cobalt-60, type Gammecell-220, at 0.210 kGy dose rate. In order to study stimulation effects of radiation on germination, plant growth and production. A treatment with four radiation doses was applied as follows: 0 (control); 12.5; 25.0 and 50.0 Gy. Seed germination and harvested of number of seeds and total production were assessed to identify occurrence of stimulation. Soya seeds number and plants were handled as for usual seed production in Brazil. The low doses of gamma radiation in the seeds that stimulate the production were the doses of 12.5 and 50.0 Gy. The results show that the use of low doses of gamma radiation can stimulate germination and plant production. (author)

  14. Low-dose ionizing radiation limitations to seed germination: Results from a model linking physiological characteristics and developmental-dynamics simulation strategy.

    Science.gov (United States)

    Liu, Hui; Hu, Dawei; Dong, Chen; Fu, Yuming; Liu, Guanghui; Qin, Youcai; Sun, Yi; Liu, Dianlei; Li, Lei; Liu, Hong

    2017-08-01

    There is much uncertainty about the risks of seed germination after repeated or protracted environmental low-dose ionizing radiation exposure. The purpose of this study is to explore the influence mechanism of low-dose ionizing radiation on wheat seed germination using a model linking physiological characteristics and developmental-dynamics simulation. A low-dose ionizing radiation environment simulator was built to investigate wheat (Triticum aestivum L.) seeds germination process and then a kinetic model expressing the relationship between wheat seed germination dynamics and low-dose ionizing radiation intensity variations was developed by experimental data, plant physiology, relevant hypotheses and system dynamics, and sufficiently validated and accredited by computer simulation. Germination percentages were showing no differences in response to different dose rates. However, root and shoot lengths were reduced significantly. Plasma governing equations were set up and the finite element analysis demonstrated H 2 O, CO 2 , O 2 as well as the seed physiological responses to the low-dose ionizing radiation. The kinetic model was highly valid, and simultaneously the related influence mechanism of low-dose ionizing radiation on wheat seed germination proposed in the modeling process was also adequately verified. Collectively these data demonstrate that low-dose ionizing radiation has an important effect on absorbing water, consuming O 2 and releasing CO 2 , which means the risk for embryo and endosperm development was higher. Copyright © 2017 Elsevier Ltd. All rights reserved.

  15. The direct biologic effects of radioactive 125I seeds on pancreatic cancer cells PANC-1, at continuous low-dose rates.

    Science.gov (United States)

    Wang, Jidong; Wang, Junjie; Liao, Anyan; Zhuang, Hongqing; Zhao, Yong

    2009-08-01

    The relative biologic effectiveness of model 6711 125I seeds (Ningbo Junan Pharmaceutical Technology Company,Ningbo, China) and their effects on growth, cell cycle, and apoptosis in human pancreatic cancer cell line PANC-1 were examined in the present study. PANC-1 cells were exposed to the absorbed doses of 1, 2, 4, 6, 8, and 10 Gyeither with 125I seeds (initial dose rate, 2.59 cGy=h) or with 60Co g-ray irradiation (dose rate, 221 cGy=min),respectively. Significantly greater numbers of apoptotic PANC-1 cells were detected following the continuouslow-dose-rate (CLDR) irradiation of 125I seeds, compared with cells irradiated with identical doses of 60Co g-ray. The D(0) for 60Co g-ray and 125I seed irradiation were 2.30 and 1.66, respectively. The survival fraction after 125Iseed irradiation was significantly lower than that of 60Co g-ray, with a relative biologic effectiveness of 1.39.PANC-1 cells were dose dependently arrested in the S-phase by 60Co g-rays and in the G2=M phase by 125I seeds,24 hour after irradiation. CLDR irradiation by 125I seeds was more effective in inducing cell apoptosis in PANC-1cells than acute high-dose-rate 60Co g irradiation. Interestingly, CLDR irradiation by 125I seeds can cause PANC-1cell-cycle arrest at the G2=M phase and induce apoptosis, which may be an important mechanism underlying 125Iseed-induced PANC-1 cell inhibition.

  16. Increase of onion yield through low dose of gamma irradiation of its seeds

    International Nuclear Information System (INIS)

    Wiendl, F.M.; Wiendl, F.W.; Wiendl, J.A.; Vedovatto, A.; Arthur, V.

    1995-01-01

    The increase of onions' yield could be achieved by the common farmer through the use of nuclear techniques. This report describes the results obtained with the irradiation of onion seeds, with low doses of gamma radiations (Cobalt-60), at doses of 0 (control), 150, 400 and 700 Gy. Beyond the proper onion's variety als use of low dose rates of 13.1, 39.2 and 52.3 Gy per hour were of the great importance during irradiation. The results showed to be promising both in laboratory studies and in the field, resulting in an increase of onions production: A greater number of seedlings, bulbs and a higher yield in weight per hectar were planted. In the field the most promising dose and dose rate to the variety ''Super-X'' were respectively 150 Gy and 13.1 Gy per hour, yielding an 24.9 percent heavier weight of onions than the control. The other tested variety was ''Granex-33'', which did not respond so favorable to irradiation. However, also with this variety we harvested a 2.1 percent heavier weight than its control, if the onion seeds were irradiated with the dose of 700 Gy at a dose rate of 13.1 Gy per hour. (Author)

  17. Effects of low dose gamma-ray radiation on the seed germination and physiological activity of vegetable crops

    Energy Technology Data Exchange (ETDEWEB)

    Kim, J. S.; Baek, M. H.; Lee, Y. G. [KAERI, Taejon (Korea, Republic of); Jung, K. H. [Kyunghee Univ., Yongin (Korea, Republic of)

    2000-10-01

    To determine the effect of low dose gamma-ray radiation on the germination rate and physiology of germinative seeds of Chinese cabbage(Brassica campestris L. cv. Hanyoreum) and radish(Raphanus sativus L. cv. Chungsukoungzoung). The germination rate of irradiation group was higher than that of the control. Especially it was highest at the early stage of induction. The germination rate of Chinese cabbage increased at 4 Gy-, 10 Gy- and 50 Gy irradiation group and that of radish increased at 2 Gy-, 6 Gy- and 10 Gy irradiation group. The seedling height of Chinese cabbage and radish increased positively in low dose irradiation group. The seedling height of Chinese cabbage was noticeably higher at 4 Gy and 10 Gy irradiation group and that of radish at 6 Gy irradiation group. The protein contents of seeds irradiated with low dose gamma-ray radiation was increased compared to that of the control especially at the early stage of induction. The enzyme activity of seeds irradiated with low dose of gamma-ray radiation was increased at 4 Gy and 10 Gy irradiation group. These results suggest that the germination and physiological activity of old seeds could be stimulated promisingly by the low dose gamma-ray radiation.

  18. The biological effect of 125I seed continuous low dose rate irradiation in CL187 cells

    Directory of Open Access Journals (Sweden)

    Zhuang Hong-Qing

    2009-01-01

    Full Text Available Abstract Background To investigate the effectiveness and mechanism of 125I seed continuous low-dose-rate irradiation on colonic cell line CL187 in vitro. Methods The CL187 cell line was exposed to radiation of 60Coγ ray at high dose rate of 2 Gy/min and 125I seed at low dose rate of 2.77 cGy/h. Radiation responses to different doses and dose rates were evaluated by colony-forming assay. Under 125I seed low dose rate irradiation, a total of 12 culture dishes were randomly divided into 4 groups: Control group, and 2, 5, and 10 Gy irradiation groups. At 48 h after irradiation, apoptosis was detected by Annexin and Propidium iodide (PI staining. Cell cycle arrests were detected by PI staining. In order to investigate the influence of low dose rate irradiation on the MAPK signal transduction, the expression changes of epidermal growth factor receptor (EGFR and Raf under continuous low dose rate irradiation (CLDR and/or EGFR monoclonal antibodies were determined by indirect immunofluorescence. Results The relative biological effect (RBE for 125I seeds compared with 60Co γ ray was 1.41. Apoptosis rates of CL187 cancer cells were 13.74% ± 1.63%, 32.58% ± 3.61%, and 46.27% ± 3.82% after 2 Gy, 5 Gy, and 10 Gy irradiation, respectively; however, the control group apoptosis rate was 1.67% ± 0.19%. G2/M cell cycle arrests of CL187 cancer cells were 42.59% ± 3.21%, 59.84% ± 4.96%, and 34.61% ± 2.79% after 2 Gy, 5 Gy, and 10 Gy irradiation, respectively; however, the control group apoptosis rate was 26.44% ± 2.53%. P 2/M cell cycle arrest. After low dose rate irradiation, EGFR and Raf expression increased, but when EGFR was blocked by a monoclonal antibody, EGFR and Raf expression did not change. Conclusion 125I seeds resulted in more effective inhibition than 60Co γ ray high dose rate irradiation in CL187 cells. Apoptosis following G2/M cell cycle arrest was the main mechanism of cell-killing effects under low dose rate irradiation. CLDR could

  19. Towards a determination of the absorbed dose to water in water for low-energy photon-emitting brachytherapy seeds

    International Nuclear Information System (INIS)

    Schneider, T.; Lange, B.; Selbach, H.J.

    2007-01-01

    An accurate determination of the dose produced by brachytherapy seeds emitting low-energy photons is an important component of the radiotherapeutic process. As yet, the output of these seeds has usually been specified in terms of the air kerma rate. The desired quantity in radiation therapy is, however, the absorbed dose to water inside a water phantom, for which primary standards are not available. For this reason, developments are under way in the Physikalisch - Technische Bundesanstalt to establish a primary standard to determine the absorbed dose to water within a phantom. As a fundamental step towards this aim, a method will be introduced in this publication to determine the water kerma inside a graphite phantom housing an extrapolation chamber. Experimental results will be presented and compared with water kerma values obtained from air kerma measurements in free air and applying a conversion factor to water kerma for the conditions of the experiment. First estimates indicate that the relative uncertainty is of the order of 1% (k 1). (authors)

  20. Optimum timing for image-based dose evaluation of 125I and 103Pd prostate seed implants

    International Nuclear Information System (INIS)

    Yue Ning; Chen Zhe; Peschel, Richard; Dicker, Adam P.; Waterman, Frank M.; Nath, Ravinder

    1999-01-01

    Purpose/Objective: Image-based dose evaluation of permanent brachytherapy implants for prostate cancer is important for optimal patient management after implantation. Because of edema caused by the surgical procedure in the implantation, if the dose evaluation is based on the images obtained too early after implantation, dose coverage will usually be underestimated. Conversely, if the images are obtained too late, the dose coverage will be overestimated. This study uses a biomathematical model to simulate edema and its resolution on 29 patients, so that the optimum time to obtain image scans and perform dose evaluation can be investigated and estimated. Methods and Materials: Edema of a prostate and its resolution has been shown to follow an exponential function V(t) = V(0)(1 + ΔV[e -0.693t/Te - 1]) where ΔV is the initial relative increase in the prostate volume due to edema (and is related to edema magnitude), and T e (edema half-life) is the time for the edema to decrease by half in volume. In this study, edema was simulated by increasing the volume of preimplant prostate (obtained from ultrasound volume study) to a given magnitude of edema. Similarly, the locations of planned seeds were changed to their corresponding locations in the edematous prostate proportionally. The edema was then allowed to resolve according to the exponential function. The correct dose distribution was calculated by taking into account the dynamic variations of the prostate volume, seed locations, and source strengths with respect to time. Dose volume histograms (DVHs) were then generated from this dose distribution. The conventional postimplant DVHs, which assume the prostate volume and seed locations are as in the image scans and constant in time, were also calculated based on the simulated image scans for various days postimplantation. The conventional DVHs of prostate on various days after implantation were compared to the DVH calculated assuming dynamic conditions. The optimum

  1. Radiation mutagenesis in lavender. I.Dose and emissive power as affecting the radiosensitivity of lavender seeds in gamma-ray treatment

    International Nuclear Information System (INIS)

    Tsvetkov, R.

    1977-01-01

    The radiosensitivity has been investigated of dormant seeds of the widely distributed aboriginal Hemus and Karlovo varieties and of the Soviet Stepnaya lavender variety in treatment with gamma rays using 60 Co. Doses within 1 to 100 kRad are applied at different emissive power of the emitter. Both irradiated and nonirradiated control seeds are gibberellic acid treated. The dynamics of seed sprouting is followed up. The number of survived plants and peculiarities of their growth are registered. The radiosensitivity of Lavandula vera D.C. seeds is modified by the emissive power in equal doses applied. Stepnaya variety showed highest resistance, followed by Karlovo and Hemus varieties. Doses are ascertained with a stimulating, inhibiting, semilethal and lethal effect in regard to the separate varietoes. Both stimulation and injuring prove to be of saltatory character. The radiation injuring of doses with an inhibitory, semilethal and lethal effect positively correlate with the dose of all tested emissive powers of the gamma-emitter. (author)

  2. Evaluation of dose-volume histograms after prostate seed implantation. 4-year experience

    International Nuclear Information System (INIS)

    Hoinkis, C.; Lehmann, D.; Winkler, C.; Herrmann, T.; Hakenberg, O.W.; Wirth, M.P.

    2004-01-01

    Background and purpose: permanent interstitial brachytherapy by seed implantation is a treatment alternative for low-volume low-risk prostate cancer and a complex interdisciplinary treatment with a learning curve. Dose-volume histograms are used to assess postimplant quality. The authors evaluated their learning curve based on dose-volume histograms and analyzed factors influencing implantation quality. Patients and methods: since 1999, 38 patients with a minimum follow-up of 6 months were treated at the authors' institution with seed implantation using palladium-103 or iodine-125, initially using the preplan method and later real-time planning. Postimplant CT was performed after 4 weeks. The dose-volume indices D90, V100, V150, the D max of pre- and postplans, and the size and position of the volume receiving the prescribed dose (high-dose volume) of the postplans were evaluated. In six patients, postplan imaging both by CT and MRI was used and prostate volumes were compared with preimplant transrectal ultrasound volumes. The first five patients were treated under external supervision. Results: patients were divided into three consecutive groups for analysis of the learning curve (group 1: n = 5 patients treated under external supervision; group 2: n = 13 patients; group 3: n = 20 patients). D90 post for the three groups were 79.3%, 74.2%, and 99.9%, the V100 post were 78.6%, 73.5%, and 88.2%, respectively. The relationship between high-dose volume and prostate volume showed a similar increase as the D90, while the relationship between high-dose volume lying outside the prostate and prostate volume remained constant. The ratio between prostate volumes from transrectal ultrasound and CT imaging decreased with increasing D90 post , while the preplanning D90 and V100 remained constant. The different isotopes used, the method of planning, and the implanted activity per prostate volume did not influence results. Conclusion: a learning curve characterized by an increase

  3. Effect of low doses gamma irradiation of cotton seeds

    International Nuclear Information System (INIS)

    Al-Oudat, M.; Khalifa, Kh.

    1996-01-01

    Field experiments and then large scale application of irradiated cotton seeds (C.V. Aleppo-40) were carried out during three seasons (1986, 1987 and 1988) for field experiment at ACSAD Station in Dier-Ezzor and 1988, 1989 and 1990 for large scale application at Euphrate's Basin, Al-Ghab and Salamia, farmers farms. The above areas were selected as they represent major cotton production areas in Syria. The aims of the experiments were to study the effect of low doses of gamma irradiation 0, 5, 10, 20, 30, 40 and 50 Gy on cotton yield and to look for the optimum dose of gamma irradiation to obtain best results. The results show that, there were positive effect (P<0.95) for doses 5-30 Gy in increasing cotton yield. The highest increase was at dose of 10 Gy. which as 19.5% higher than control. For the large scale application using 10 Gy the increase in cotton yield varied from 10-39% compared to control. (author). 11 refs., 6 figs

  4. Effect of different doses of gamma rays on seed germination of Carthamus L

    International Nuclear Information System (INIS)

    Malik, Anjali; Srivastava, A.K.

    2010-01-01

    Genetic variability is essential for any crop improvement programme. Experimentally induced mutation provides an important source of variability. The ionizing radiation treatment would be useful on account of the total randomness of action of radiation on genetic material as also the fact that an optimal dose radiation produces effect both through gene mutation and chromosomal mutations. The most commonly used ionizing radiation in plant improvement program are γ-rays. The control sets of different accessions/species showed significant variability in the germination pattern. γ-ray alteration in the mean total seed germination frequency of Carthamus accessions/species presently explored, was genotype dependent. However, these could also modify substantially the temporal patterns of the germination as compared to corresponding control sets. The seed lots of different accessions could be supposed to be a mixture of seeds showing differences in the time of induction of germination. That is, seed lots differed in their temporal seed germination pattern. On the basis of the present study it can be inferred that the temporal seed germination could be decided at genotypic and/or biochemical levels. (author)

  5. SU-F-T-46: The Effect of Inter-Seed Attenuation and Tissue Composition in Prostate 125I Brachytherapy Dose Calculations

    Energy Technology Data Exchange (ETDEWEB)

    Tamura, K; Araki, F; Ohno, T [Kumamoto University, Kumamoto, Kumamoto (Japan)

    2016-06-15

    Purpose: To investigate the difference of dose distributions with/without the effect of inter-seed attenuation and tissue compositions in prostate {sup 125}I brachytherapy dose calculations, using Monte Carlo simulations of Particle and Heavy Ion Transport code System (PHITS). Methods: The dose distributions in {sup 125}I prostate brachytherapy were calculated using PHITS for non-simultaneous and simultaneous alignments of STM1251 sources in water or prostate phantom for six patients. The PHITS input file was created from DICOM-RT file which includes source coordinates and structures for clinical target volume (CTV) and organs at risk (OARs) of urethra and rectum, using in-house Matlab software. Photon and electron cutoff energies were set to 1 keV and 100 MeV, respectively. The dose distributions were calculated with the kerma approximation and the voxel size of 1 × 1 × 1 mm{sup 3}. The number of incident photon was set to be the statistical uncertainty (1σ) of less than 1%. The effect of inter-seed attenuation and prostate tissue compositions was evaluated from dose volume histograms (DVHs) for each structure, by comparing to results of the AAPM TG-43 dose calculation (without the effect of inter-seed attenuation and prostate tissue compositions). Results: The dose reduction due to the inter-seed attenuation by source capsules was approximately 2% for CTV and OARs compared to those of TG-43. In additions, by considering prostate tissue composition, the D{sub 90} and V{sub 100} of CTV reduced by 6% and 1%, respectively. Conclusion: It needs to consider the dose reduction due to the inter-seed attenuation and tissue composition in prostate {sup 125}I brachytherapy dose calculations.

  6. Influence of radiation dose and dose-rate on modification of barley seed radiosensitivity by post-treatment with caffeine

    International Nuclear Information System (INIS)

    Sharma, G.J.

    1987-01-01

    Influence of radiation doses (100, 150 and 200 Gy) and dose-rates (1.27-0.023 Gy/Sec) on the modification of oxic and anoxic radiation damage by caffeine at different concentrations has been investigated using metabolizing barley seeds as test system. As the radiation dose increases from 100 to 200 Gy, the magnitude of oxic and anoxic damages increase at all the dose-rates. Caffeine is able to afford partial radioprotection against the oxic damage, at the same time potentiating the anoxic damage. However, caffeine effect against the oxic and anoxic components of damage depend largely upon the dose of radiation applied and also on the dose-rate used. The possible mechanism of action of caffeine in bringing about the differential modification of oxic and anoxic damages has been discussed. 19 refs., 2 tables. (author)

  7. Postimplantation Analysis Enables Improvement of Dose-Volume Histograms and Reduction of Toxicity for Permanent Seed Implantation

    International Nuclear Information System (INIS)

    Wust, Peter; Postrach, Johanna; Kahmann, Frank; Henkel, Thomas; Graf, Reinhold; Cho, Chie Hee; Budach, Volker; Boehmer, Dirk

    2008-01-01

    Purpose: To demonstrate how postimplantation analysis is useful for improving permanent seed implantation and reducing toxicity. Patients and Methods: We evaluated 197 questionnaires completed by patients after permanent seed implantation (monotherapy between 1999 and 2003). For 70% of these patients, a computed tomography was available to perform postimplantation analysis. The index doses and volumes of the dose-volume histograms (DVHs) were determined and categorized with respect to the date of implantation. Differences in symptom scores relative to pretherapeutic status were analyzed with regard to follow-up times and DVH descriptors. Acute and subacute toxicities in a control group of 117 patients from an earlier study (June 1999 to September 2001) by Wust et al. (2004) were compared with a matched subgroup from this study equaling 110 patients treated between October 2001 and August 2003. Results: Improved performance, identifying a characteristic time dependency of DVH parameters (after implantation) and toxicity scores, was demonstrated. Although coverage (volume covered by 100% of the prescription dose of the prostate) increased slightly, high-dose regions decreased with the growing experience of the users. Improvement in the DVH and a reduction of toxicities were found in the patient group implanted in the later period. A decline in symptoms with follow-up time counteracts this gain of experience and must be considered. Urinary and sexual discomfort was enhanced by dose heterogeneities (e.g., dose covering 10% of the prostate volume, volume covered by 200% of prescription dose). In contrast, rectal toxicities correlated with exposed rectal volumes, especially the rectal volume covered by 100% of the prescription dose. Conclusion: The typical side effects occurring after permanent seed implantation can be reduced by improving the dose distributions. An improvement in dose distributions and a reduction of toxicities were identified with elapsed time between

  8. Dosimetric study of a new polymer encapsulated palladium-103 seed

    International Nuclear Information System (INIS)

    Bernard, S; Vynckier, S

    2005-01-01

    The use of low-energy photon emitters for brachytherapy applications, as in the treatment of prostate or ocular tumours, has increased significantly over the last few years. Several new seed models utilizing 103 Pd and 125 I have recently been introduced. Following the TG43U1 recommendations of the AAPM (American Association of Physicists in Medicine) (Rivard et al 2004 Med. Phys. 31 633), dose distributions around these low-energy photon emitters are characterized by the dose rate constant, the radial dose function and the anisotropy function in water. These functions and constants can be measured for each new seed in a solid phantom (i.e. solid water such as WT1) using high spatial resolution detectors such as very small thermoluminescent detectors. These experimental results in solid water must then be converted into liquid water by using Monte Carlo simulations. This paper presents the dosimetric parameters of a new palladium seed, OptiSeed TM (produced by International Brachytherapy (IBt), Seneffe, Belgium), made with a biocompatible polymeric shell and with a design that differs from the hollow titanium encapsulated seed, InterSource 103 , produced by the same company. A polymer encapsulation was chosen by the company IBt in order to reduce the quantity of radioactive material needed for a given dose rate, and to improve the symmetry of the radiation field around the seed. The necessary experimental data were obtained by measurements with LiF thermoluminescent dosimeters (1 mm 3 ) in a solid water phantom (WT1) and then converted to values in liquid water using Monte Carlo calculations (MCNP-4C). Comparison of the results with a previous study by Reniers et al (2002 Appl. Radiat. Isot. 57 805) shows very good agreement for the dose rate constant and for the radial dose function. In addition, the results also indicate an improvement in isotropy compared to a conventional titanium encapsulated seed. The relative dose (anisotropy value relative to 90 deg.) from

  9. Autoradiography for iodine-125 seeds

    International Nuclear Information System (INIS)

    Alberti, W.; Divoux, S.; Pothmann, B.; Tabor, P.; Hermann, K.P.; Harder, D.

    1993-01-01

    To study the interior design of model 6702 and 6711 iodine-125 seeds, contact autoradiographs were performed using mammography film. Improved resolution was obtained using a pin-hole camera with a hole of 0.1 mm x 0.1 mm. With these techniques, qualitative determination of the relative activity distribution within each seed was possible. The number of the activated resin spheres and the positions of the centers of these spheres can be exactly determined. A model calculation shows that variations in the arrangement of the activated spheres within a seed have a moderate influence on the dose distribution at source distances below 10 mm. Knowing the exact source configuration may be useful when comparing dose calculations with measured data for model 6702 125 I seeds which are currently employed in ophthalmic plaque and implant therapy of other tumors. 16 refs., 5 figs., 2 tabs

  10. Effects of low dose gamma irradiation on the germination and physiological activity of old red pepper (Capsicum annuum L.) seed

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Jae Sung; Back, Myung Hwa; Lee, Hae Youn; Lee, Young Keun [KAERI, Daejeon (Korea, Republic of)

    2001-12-15

    To observe the stimulating effects of low dose gamma radiation on the germination and physiological activity of germinating seeds of old red pepper (Capsicum annuum L. cv, Jokwang and cv. Hongkwang), seeds were irradiated at the dose of 2{approx}50 Gy. The germination rate of irradiation group was higher than that of the control. Especially it was highest at the early stage of induction. The germination rate at 7 days after sowing in Jokwang and Hongkwang cultivar was high as 74% and 11% at 4 Gy and 8 Gy irradiation group, respectively. The seedling height of Jokwang cultivar was noticeably high at 4 Gy irradiation group and that of Hongkwang cultivar at 8 Gy Irradiation group. The protein contents of seedlings from seeds irradiated with low dose gamma radiation of Jokwang cultivar increased at the late stage of induction and that of Hongkwang cultivar at the early stage of induction. Catalase and peroxidase activities of seedlings from seeds irradiated with low dose gamma radiation of Jokwang cultivar increased at 4 Gy irradiation group and that of Hongkwang cultivar at 8 Gy irradiation group.

  11. Neutron irradiation of seeds 2

    Energy Technology Data Exchange (ETDEWEB)

    1968-10-01

    The irradiation of seeds with the fast neutron of research reactors has been hampered by difficulties in accurately measuring dose and in obtaining repeatable and comparable results. Co-ordinated research under an international program organized by the FAO and IAEA has already resulted in significant improvements in methods of exposing seeds in research reactors and in obtaining accurate dosimetry. This has been accomplished by the development of a standard reactor facility for the neutron irradiation of seeds and standard methods for determining fast-neutron dose and the biological response after irradiation. In this program various divisions of the IAEA and the Joint FAO/IAEA Division co-operate with a number of research institutes and reactor centres throughout the world. Results of the preliminary experiments were reported in Technical Reports Series No. 76, ''Neutron Irradiation of Seeds''. This volume contains the proceedings of a meeting of co-operators in the FAO/IAEA Neutron Seed Irradiation Program and other active scientists in this field. The meeting was held in Vienna from 11 to 15 December 1967. Refs, figs and tabs.

  12. Neutron irradiation of seeds 2

    International Nuclear Information System (INIS)

    1968-01-01

    The irradiation of seeds with the fast neutron of research reactors has been hampered by difficulties in accurately measuring dose and in obtaining repeatable and comparable results. Co-ordinated research under an international program organized by the FAO and IAEA has already resulted in significant improvements in methods of exposing seeds in research reactors and in obtaining accurate dosimetry. This has been accomplished by the development of a standard reactor facility for the neutron irradiation of seeds and standard methods for determining fast-neutron dose and the biological response after irradiation. In this program various divisions of the IAEA and the Joint FAO/IAEA Division co-operate with a number of research institutes and reactor centres throughout the world. Results of the preliminary experiments were reported in Technical Reports Series No. 76, ''Neutron Irradiation of Seeds''. This volume contains the proceedings of a meeting of co-operators in the FAO/IAEA Neutron Seed Irradiation Program and other active scientists in this field. The meeting was held in Vienna from 11 to 15 December 1967. Refs, figs and tabs

  13. Behavior of pea saber plants (Canavalia ensiformis (L) DC)) ontenus from seeds exposed to increasing doses of gamma radiation

    International Nuclear Information System (INIS)

    Kalonji, M.A.; Mudibu wa Kabangu, J.; Tshilenge-Djim, P.; Tshivuila, T.D.; Gaza, O.C.

    2003-01-01

    The present trial has carried out in order to determine the optimal value of usable treatment for seeds exposed to the gamma radiances. Seeds of Canavalia ensiformis presenting a rate of humidity of 15% have been submitted to the increasing doses of irradiation (source Cesium 137) of 10, 20, 30, 40 and 50 Krads. After germination, plants generated from these seeds have been observed in a completely randomized blocks experimental design, including six treatments and three repetitions. Observations concerned the vegetative parameters (germination percent, height, diameter to the collar, number of ramification, surface of leaves), the generative parameters (number of pod by plant, length and width of pods, number of seeds by pod, weights of 100 seeds) and the morphological changes on distortions of plants during their vegetative development. Results permitted to determine that the optimal value of treatment is located to 10 Krads. This dose induced a high rate of seed germination, vigorous plants with a high number of ramifications. The yield parameters obtained with 10 and 20 Krads, excepted the weight of 100 seeds, have been lower than to those obtained with the control. This is the consequence of the increase of the pod dimension and the size of seeds. All treatments superior to 30 Krads have been lethal. Materials treated to 10 and 20 Krads are under observation for the second generation.

  14. Measurements and simulations of seeded electron microbunches with collective effects

    Directory of Open Access Journals (Sweden)

    K. Hacker

    2015-09-01

    Full Text Available Measurements of the longitudinal phase-space distributions of electron bunches seeded with an external laser were done in order to study the impact of collective effects on seeded microbunches in free-electron lasers. When the collective effects of Coulomb forces in a drift space and coherent synchrotron radiation in a chicane are considered, velocity bunching of a seeded microbunch appears to be a viable alternative to compression with a magnetic chicane under high-gain harmonic generation seeding conditions. Measurements of these effects on seeded electron microbunches were performed with a rf deflecting structure and a dipole magnet which streak out the electron bunch for single-shot images of the longitudinal phase-space distribution. Particle tracking simulations in 3D predicted the compression dynamics of the seeded microbunches with collective effects.

  15. Effects of gamma irradiation on chickpea seeds vis-a-vis total seed storage proteins, antioxidant activity and protein profiling.

    Science.gov (United States)

    Bhagyawant, S S; Gupta, N; Shrivastava, N

    2015-10-23

    The present work describes radiation—induced effects on seed composition vis—à—vis total seed proteins, antioxidant levels and protein profiling employing two dimensional gel electrophoresis (2D—GE) in kabuli and desi chickpea varities. Seeds were exposed to the radiation doses of 1,2,3,4 and 5 kGy. The total protein concentrations decreased and antioxidant levels were increased with increasing dose compared to control seed samples. Radiation induced effects were dose dependent to these seed parameters while it showed tolerance to 1 kGy dose. Increase in the dose was complimented with increase in antioxidant levels, like 5 kGy enhanced % scavenging activities in all the seed extracts. Precisely, the investigations reflected that the dose range from 2 to 5 kGy was effective for total seed storage proteins, as depicted quantitatively and qualitative 2D—GE means enhance antioxidant activities in vitro.

  16. Direct determination of the absorbed dose to water from 125I low dose-rate brachytherapy seeds using the new absorbed dose primary standard developed at ENEA-INMRI

    International Nuclear Information System (INIS)

    Toni, M.P.; Pimpinella, M.; Pinto, M.; Quini, M.; Cappadozzi, G.; Silvestri, C.; Bottauscio, O.

    2012-01-01

    Low-intensity radioactive sources emitting low-energy photons are used in the clinic for low dose-rate brachytherapy treatments of tumours. The dosimetry of these sources is based on reference air kerma rate measurements. The absorbed dose rate to water at the reference depth d 0 = 1 cm, D w , 1 cm, is then obtained by a conversion procedure with a large relative standard uncertainty of about 5%. This paper describes a primary standard developed at ENEA-INMRI to directly measure D w , 1 cm due to LDR sources. The standard is based on a large-angle and variable-volume ionization chamber, embedded in a graphite phantom and operating under 'wall-less air chamber' conditions. A set of correction and conversion factors, based on experiments and Monte Carlo simulations, are determined to obtain the value of D w , 1 cm from measurements of increment of ionization current with increasing chamber volume. The relative standard uncertainty on D w , 1 cm is 2.6%, which is appreciably lower than the current uncertainty. Characteristics of the standard, its associated uncertainty budget, and some experimental results are given for 125 I BEBIG I25.S16.C brachytherapy seeds. Finally, results of the experimental determination of the dose-rate constant 1 cm, traceable to the D w , 1 cm and the low-energy air kerma ENEA-INMRI standards, are given. The relative standard uncertainty on 1 cm is 2.9%, appreciably lower than the typical uncertainty (4.8%) of the values available in the literature. (authors)

  17. Effect of low dose irradiation of 60Co γ-rays on seed germination, seedling growth and enzymes activity of Lactuca sativa

    International Nuclear Information System (INIS)

    Liu Xiuqing; Zhang Tie

    2012-01-01

    The seeds of Lactuca sativa were irradiated by different doses (10, 20, 30, 40, 50 Gy) of 60 Co γ-rays. The effects of low dose irradiation on seed germination, seedling growth and enzymes activity were investigated. The results indicated that low dose irradiation could promote germination rate, germinating viability, germination rate in the field, root length and height of seedling. The suitable dosage for low dose irradiation for Lactuca sativa was 30 Gy. POD activity after irradiation treatment in the range of 10 to 50 Gy and CAT activity after irradiation treatment in the range of 20 Gy to 40 Gy was lower than that of control. (authors)

  18. Effect of low doses of gamma radiation of Co-60 (radio-hormesis) in tomato seeds

    International Nuclear Information System (INIS)

    Wiendl, Toni Andreas

    2010-01-01

    Tomato seeds of the Gladiador hybrid were exposed to gamma radiation of Co-60 with the following doses: 0; 2,5; 5; 7,5; 10; 12,5; 15 e 20 Gy. Analysis were performed on germination, seedlings height to cotyledon, seedling total height, seedling fresh and dry weight, plant height, stalk diameter at the root beginning, fresh and dry weight of the 5 th leaf, number of green fruits with diameter higher than 3 cm, number of green, half ripen and ripen fruits, total number of fruits, Brix and pH of fruits, average fruit weight and fruit total production. A variety of stimulation effects were observed on the different plant developing stages. The greatest stimulus for production was observed in the 10 Gy dose. The highest seedling average height and plant average height were observed for the 7,5 Gy dose. The biggest number of green fruits with diameter higher than 3 cm occurred for the 12,5 and 15 Gy treatments. Irradiation also stimulated a higher total number of fruits in all doses, having advantage the 10 Gy dose which produced 88% more fruits than control as well as 86% more weight production. The fruits pH acidified significantly in a dose of 12,5 Gy and higher. Production increased in all treatments comparing to control and the highest stimulus for production observed was for the 10, 12,5 and 15 Gy. The use of low gamma radiation doses of Co-60 applied as pre-sowing treatment in the seeds, efficiently stimulated the development of plants and the tomato production. (author)

  19. The incidence of radioepidermitis and the dose-response relationship in parotid gland cancer patients treated with 125I seed brachytherapy. Incidence of radioepidermitis and the dose-response relationship

    Energy Technology Data Exchange (ETDEWEB)

    Mao, Ming-Hui; Zheng, Lei; Gao, Hong; Zhang, Jie; Liu, Shu-ming; Huang, Ming-wei; Shi, Yan [Peking University School and Hospital of Stomatology, Department of Oral and Maxillofacial Surgery, Beijing (China); Zhang, Jian-Guo [Peking University School and Hospital of Stomatology, Department of Oral and Maxillofacial Surgery, Beijing (China); Fujian Provincial Hospital, Fujian (China)

    2014-09-09

    We studied the incidence and dose-response relationship of radioepidermitis in parotid gland carcinoma patients treated with [{sup 125}I] seed brachytherapy in the hopes of designing an optimized pre-implant treatment plan that would reduce the incidence and severity of radioepidermitis in patients receiving this therapy. Between January 2007 and May 2010, 100 parotid gland cancer patients were treated postoperatively with [{sup 125}I] seed brachytherapy. The matched peripheral dose (MPD) was 80-140 Gy, and [{sup 125}I] seed activity was 0.7-0.8 mCi. The mean dose delivered to the skin was calculated in the post-implant CT on day 0 following implantation. Grades of acute and late dermatitis were evaluated at 2, 6, 12, and 18 months post-implantation. Most patients experienced grade 0-2 acute and late skin side effects (86 and 97 %, respectively), though a small subset developed severe complications. Most grade 1-3 effects resolved within 6 months of implantation, though some grade 1-3 effects and all grade 4 effects remained unchanged throughout the 18-month follow-up period. Grade 3 and 4 effects were most prominent (75 and 25 %, respectively) with doses of 110-140 Gy; doses higher than 140 Gy produced only grade 4 effects. [{sup 125}I] seed brachytherapy produced acceptable levels of acute and late radioepidermitis with a good clinical outcome. A mean dose under 100 Gy delivered to the skin was safe, though doses of 110-140 Gy should be given with caution and extra monitoring; doses greater than 140 Gy are dangerous and likely to produce grade 4-5 effects. (orig.) [German] Wir untersuchten die Inzidenz und die Dosis-Wirkung-Beziehung bei Patienten mit Ohrspeicheldruesenkrebs, die mit [{sup 125}I]-Seed-Brachytherapie behandelt wurden, in der Hoffnung, eine optimierte praeimplantologische Behandlung zu entwickeln, welche die Inzidenz und Schwere der Radioepidermitis bei Patienten, die diese Therapie erhalten haben, reduziert. Zwischen Januar 2007 und Mai 2010

  20. The Effect of Scattering from Leg Region on Organ Doses in Prostate Brachytherapy for 103Pd, 125I and 131Cs Seeds

    Directory of Open Access Journals (Sweden)

    Seyed Milad Vahabi

    2016-09-01

    Full Text Available Introduction Dose calculation of tumor and surrounding tissues is essential during prostate brachytherapy. Three radioisotopes, namely, 125I, 103Pd, and 131Cs, are extensively used in this method. In this study, we aimed to calculate the received doses by the prostate and critical organs using the aforementioned radioactive seeds and to investigate the effect of scattering contribution for the legs on dose calculations. Materials and Methods The doses to organs of interest were calculated using MCNPX code and ORNL (Oak Ridge National Laboratory phantom. Results Doses to the prostate as a source of radiation for 125I, 103Pd, and 131Cs were approximately 108.9, 97.7, and 81.5 Gy, respectively. Bladder, sigmoid colon, and testes received higher doses than other organs due to proximity to the prostate. Differences between the doses when tallying with the legs intact and with the legs voided were significant for testes, sigmoid colon contents, and sigmoid colon wall because of their proximity to the prostate. There was also a good consistency between our results and the data published by Montefiore Medical Center and Albert Einstein College of Medicine for the prostate. Conclusion Scattering from leg region had a significant effect on doses to testes, sigmoid colon contents, and sigmoid colon wall in the pelvic region, and prostate and the other organs were unaffected. Brachytherapy treatment plans using 131Cs seeds allow for better sparing of critical tissues, with a comparable number of, or fewer, seeds required, compared to 125I seeds.

  1. Bystander effects of exposure to low-dose-rate 125I seeds on human lung cancers cells in vitro

    International Nuclear Information System (INIS)

    Jia Rongfei; Chen Honghong; Yu Lei; Zhao Meijia; Shao Chunlin; Cheng Wenying

    2007-01-01

    The bystander effects induced by continuous low-dose-rate (LDR) 125 I seeds radiation on damage of human lung cancer cells were investigated. Human adenocarcinoma cell line A549 and human small cell lung cancer cell line NCI-H446, which have different sensitivities to high-dose rate (HDR) external irradiation, were exposed directly to 125 I seeds in vitro and co-cultured with unirradiated cells for 24 h. Using cytokinesis-blocking micronucleus method and γ H2AX fluorescence immunoassay, bystander effects induced by 2Gy and 4Gy 125 I seed irradiation on micronucleus formation and DNA double-strand breaks (DSBs) of human lung cancer cells were detected and evaluated. The results showed that irradiation with 125 I seeds can induce medium-mediated bystander effects in A549 cells and NCI-H446 cells, exhibiting that both micronuclei formation and γ H2AX focus formation in bystander cells were increased significantly compared with non-irradiated cells. The extent of DNA damage induced by bystander effects was correlated with accumulated radiation dose and radiosensitive of tumor cells. NCI-H446 cells that were sensitive to HDR γ irradiation were more sensitive to continuous LDR irradiation and bystander effects than A549. However, a comparison between the bystander effects and direct effects elicits the intensity of bystander responses of A549 cells was higher than that of NCI-H446 cells. A dose-related reduction in bystander responses was observed both in A549 cells and NCI-H446 cells, suggesting that the signaling factors involved in the bystander signaling pathways may decrease with the increase of cell damages. (authors)

  2. Dose measurements in mammography

    International Nuclear Information System (INIS)

    Kainberger, F.; Kallinger, W.

    1977-01-01

    Dose measurements at the mamma during mammography were carried out in the form of direct measurement with thermoluminescent dosimetry. Measurement was done for the in- and outcoming doses at the mamma, the dose exposure of the sternal region and the scattered rays above the symphysis, the latter as parameter for the genetic radiation exposure. As expected, the dose of the smooth radiation used for mammography showed a strong decrease at the outcome point in comparison with the income point. Surprisingly high was the scattered radiation in the sternal region. A corresponding protection by lead plates could be taken into consideration. Extremely low is the scattered radiation above the symphysis. Even measurements with the very sensitive calcium fluoride dosimeters did not reveal any practically important dose in the symphysis region. Most measurement values remained below the determinable dose of 0.3mR. Some maximal values varied in the range of 3-1 mR. (orig.) [de

  3. A non-invasive and rapid seed vigor biosensor based on quantitative measurement of superoxide generated by aleurone cell in intact seeds.

    Science.gov (United States)

    Liu, Xuejun; Gao, Caiji; Xing, Da

    2009-02-15

    Superoxide generated during the early imbibition is an excellent marker for evaluating seed vigor. In this paper, a new principle biosensor for non-invasive detection of seed vigor based on quantitative measurement of superoxide via selective probe 2-methyl-6-(p-methoxyphenyl)-3,7-dihydroimidazo [1,2alpha] pyrazin-3-one (MCLA)-mediated chemiluminescence (CL) was developed. The biosensor, which used a compact single-photon counting module (SPCM) to collect the CL signal, could evaluate seed vigor in vivo. Benefiting from the high CL efficiency of MCLA reacting with superoxide and high sensitivity of the SPCM technique, the trace superoxide generated by dry seeds under storage state can be detected to achieve rapid and non-invasive determination of the seed vigor. In comparison with the traditional methods for fast measuring seed vigor based on measurement of physiological and biochemical properties, our proposed technique has significant advantages such as low cost, simplicity, convenient operation and short time consuming. To demonstrate the utility of the system, it was applied to evaluate MCLA-mediated CL of three different plant species wheat (Ze Yu No. 2), maize (Tai Gu No. 1 and 2) and rice (Jing Dao No. 21) seeds with different degrees of aging. The experimental results suggested that there was an excellent positive correlation between the seed vigor assessment from quantitative TTC-test and the detection based on MCLA-mediated CL of superoxide measurement. The new principle of seed vigor measurement is a challenge and breakthrough to conventional method of seed vigor determination and may be a potential technique of the next generation seed vigor detection.

  4. SU-F-T-43: Prediction of Dose Increments by Brain Metastases Resection Cavity Shrinkage Model with I-125 and Cs-131 LDR Seed Implantations

    Energy Technology Data Exchange (ETDEWEB)

    Han, D; Braunstein, S; Sneed, P; McDermott, M; Ma, L [University of California San Francisco, San Francisco, CA (United States)

    2016-06-15

    Purpose: This work aims to determine dose variability via a brain metastases resection cavity shrinkage model (RC-SM) with I-125 or Cs-131 LDR seed implantations. Methods: The RC-SM was developed to represent sequential volume changes of 95 consecutive brain metastases patients. All patients underwent serial surveillance MR and change in cavity volume was recorded for each patient. For the initial resection cavity, a prolate-ellipsoid cavity model was suggested and applied volume shrinkage rates to correspond to 1.7, 3.6, 5.9, 11.7, and 20.5 months after craniotomy. Extra-ring structure (6mm) was added on a surface of the resection volume and the same shrinkage rates were applied. Total 31 LDR seeds were evenly distributed on the surface of the resection cavity. The Amersham 6711 I-125 seed model (Oncura, Arlington Heights, IL) and the Model Cs-1 Rev2 Cs-131 seed model (IsoRay, Richland, WA) were used for TG-43U1 dose calculation and in-house-programed 3D-volumetric dose calculation system was used for resection cavity rigid model (RC-RM) and the RC-SM dose calculation. Results: The initial resection cavity volume shrunk to 25±6%, 35±6.8%, 42±7.7%, 47±9.5%, and 60±11.6%, with respect to sequential MR images post craniotomy, and the shrinkage rate (SR) was calculated as SR=56.41Xexp(−0.2024Xt)+33.99 and R-square value was 0.98. The normal brain dose as assessed via the dose to the ring structure with the RC-SM showed 29.34% and 27.95% higher than the RC-RM, I-125 and Cs-131, respectively. The dose differences between I-125 and Cs-131 seeds within the same models, I-125 cases were 9.17% and 10.35% higher than Cs-131 cases, the RC-RM and the RC-SM, respectively. Conclusion: A realistic RC-SM should be considered during LDR brain seed implementation and post-implement planning to prevent potential overdose. The RC-SM calculation shows that Cs-131 is more advantageous in sparing normal brain as the resection cavity volume changes with the LDR seeds implementation.

  5. Statistical differences and systematic effect on measurement procedure in thermoluminescent dosimetry of the Iodine-125 brachytherapy seed

    International Nuclear Information System (INIS)

    Zeituni, Carlos A.; Moura, Eduardo S.; Rostelato, Maria Elisa C.M.; Manzoli, Jose E.; Moura, Joao Augusto; Feher, Anselmo; Karam, Dib

    2009-01-01

    In order to provide the dosimetry for Iodine-125 seed production in Brazil, Harshaw thermoluminescent dosimeters (TLD-100) will be used. Even if measurements with TLD-100 of the same batch of fabrication are performed, the response will not be the same. As a consequence, they must be measured one by one. These dosimeters are LiF type with a micro-cube (1 mm x 1 mm x 1 mm) shape. Irradiations were performed using Iodine-125 seeds to guarantee the same absorbed dose of 5 Gy in each dosimeter. It has been used a Solid Water Phantom with three concentrically circle with 20 mm, 50 mm and 70 mm diameters. The angle of positions used was 0 deg, 30 deg, 60 deg and 90 deg. Of course there are 2 positions in 0 deg and 90 deg and 4 positions in 30 deg and 60 deg. These complete procedures were carried out five times in order to compare the data and minimize the systematic error. The iodine-125 seed used in the experiment was take off in each measure and put again turning his position 180 deg to guarantee the systematic error was minimized. This paper presents also a little discussion about the statistical difference in the measurement and the calculation procedure to determine the systematic error in these measurements. (author)

  6. Statistical differences and systematic effect on measurement procedure in thermoluminescent dosimetry of the Iodine-125 brachytherapy seed

    Energy Technology Data Exchange (ETDEWEB)

    Zeituni, Carlos A.; Moura, Eduardo S.; Rostelato, Maria Elisa C.M.; Manzoli, Jose E.; Moura, Joao Augusto; Feher, Anselmo, E-mail: czeituni@ipen.b [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP) Sao Paulo, SP (Brazil); Karam, Dib [Universidade de Sao Paulo (USP Leste), Sao Paulo, SP (Brazil). Escola de Artes, Ciencias e Humanidades

    2009-07-01

    In order to provide the dosimetry for Iodine-125 seed production in Brazil, Harshaw thermoluminescent dosimeters (TLD-100) will be used. Even if measurements with TLD-100 of the same batch of fabrication are performed, the response will not be the same. As a consequence, they must be measured one by one. These dosimeters are LiF type with a micro-cube (1 mm x 1 mm x 1 mm) shape. Irradiations were performed using Iodine-125 seeds to guarantee the same absorbed dose of 5 Gy in each dosimeter. It has been used a Solid Water Phantom with three concentrically circle with 20 mm, 50 mm and 70 mm diameters. The angle of positions used was 0 deg, 30 deg, 60 deg and 90 deg. Of course there are 2 positions in 0 deg and 90 deg and 4 positions in 30 deg and 60 deg. These complete procedures were carried out five times in order to compare the data and minimize the systematic error. The iodine-125 seed used in the experiment was take off in each measure and put again turning his position 180 deg to guarantee the systematic error was minimized. This paper presents also a little discussion about the statistical difference in the measurement and the calculation procedure to determine the systematic error in these measurements. (author)

  7. Effect of seed treatment using low doses of X-rays in peppers plants (Capsicum annuum L.)

    International Nuclear Information System (INIS)

    Alvarez Fonseca, Alexander; Chavez Suarez, Licet; Ramirez Fernandez, Ramiro

    2013-01-01

    The influence of seed treatment with X-rays radiation on the growth and yield of peppers plants of the California Wonder variety was studied. The seeds were irradiated with X- rays irradiation source of low potency (11.47 Gy/min), with doses of 5, 10, 20 y 30 Gy, using untreated seeds as controls. Plant height (mm), root length (mm), stem diameter (mm), polar average diameter (mm) ecuatorial mean diameter (mm), mean fruit mass (g) and yield per plant (kg.plant''1 ) were evaluated. The results showed a significant improvement (p≤ 0.001) in the indicators of plants height (15%), root length (12%), stem diameter (7%), equatorial mean diameter (47%), mean fruit mass (16%) and yield per plant (107%), compared to control

  8. Monte Carlo simulation of the dose distribution around the 125I model 6711 seed as function of radius of the silver cylinder using the Penelope code

    International Nuclear Information System (INIS)

    Nerio, U.; Chica, L.; Paul, A.

    2004-01-01

    The Monte Carlo method is applied to find the dose rates distribution in tissue around 125 I seeds model 6711 as a function of the silver cylinder radius, R sc (0.017, 0.021, 0.025, 0.029 and 0.033) cm are used as radius values. It is found here that the dose rate at any point within the tissue decreases as R sc increases. The relative difference of dose rate that produced by the standard R sc seed, is less than 5%, for seeds with Rsc between 0.017 and 0.033 cm. (author)

  9. Dosimetric and radiobiological comparison of volumetric modulated arc therapy, high-dose rate brachytherapy, and low-dose rate permanent seeds implant for localized prostate cancer

    Energy Technology Data Exchange (ETDEWEB)

    Yang, Ruijie, E-mail: ruijyang@yahoo.com; Zhao, Nan; Liao, Anyan; Wang, Hao; Qu, Ang

    2016-10-01

    To investigate the dosimetric and radiobiological differences among volumetric modulated arc therapy (VMAT), high-dose rate (HDR) brachytherapy, and low-dose rate (LDR) permanent seeds implant for localized prostate cancer. A total of 10 patients with localized prostate cancer were selected for this study. VMAT, HDR brachytherapy, and LDR permanent seeds implant plans were created for each patient. For VMAT, planning target volume (PTV) was defined as the clinical target volume plus a margin of 5 mm. Rectum, bladder, urethra, and femoral heads were considered as organs at risk. A 78 Gy in 39 fractions were prescribed for PTV. For HDR and LDR plans, the dose prescription was D{sub 90} of 34 Gy in 8.5 Gy per fraction, and 145 Gy to clinical target volume, respectively. The dose and dose volume parameters were evaluated for target, organs at risk, and normal tissue. Physical dose was converted to dose based on 2-Gy fractions (equivalent dose in 2 Gy per fraction, EQD{sub 2}) for comparison of 3 techniques. HDR and LDR significantly reduced the dose to rectum and bladder compared with VMAT. The D{sub mean} (EQD{sub 2}) of rectum decreased 22.36 Gy in HDR and 17.01 Gy in LDR from 30.24 Gy in VMAT, respectively. The D{sub mean} (EQD{sub 2}) of bladder decreased 6.91 Gy in HDR and 2.53 Gy in LDR from 13.46 Gy in VMAT. For the femoral heads and normal tissue, the mean doses were also significantly reduced in both HDR and LDR compared with VMAT. For the urethra, the mean dose (EQD{sub 2}) was 80.26, 70.23, and 104.91 Gy in VMAT, HDR, and LDR brachytherapy, respectively. For localized prostate cancer, both HDR and LDR brachytherapy were clearly superior in the sparing of rectum, bladder, femoral heads, and normal tissue compared with VMAT. HDR provided the advantage in sparing of urethra compared with VMAT and LDR.

  10. Dosimetric and radiobiological comparison of volumetric modulated arc therapy, high-dose rate brachytherapy, and low-dose rate permanent seeds implant for localized prostate cancer

    International Nuclear Information System (INIS)

    Yang, Ruijie; Zhao, Nan; Liao, Anyan; Wang, Hao; Qu, Ang

    2016-01-01

    To investigate the dosimetric and radiobiological differences among volumetric modulated arc therapy (VMAT), high-dose rate (HDR) brachytherapy, and low-dose rate (LDR) permanent seeds implant for localized prostate cancer. A total of 10 patients with localized prostate cancer were selected for this study. VMAT, HDR brachytherapy, and LDR permanent seeds implant plans were created for each patient. For VMAT, planning target volume (PTV) was defined as the clinical target volume plus a margin of 5 mm. Rectum, bladder, urethra, and femoral heads were considered as organs at risk. A 78 Gy in 39 fractions were prescribed for PTV. For HDR and LDR plans, the dose prescription was D 90 of 34 Gy in 8.5 Gy per fraction, and 145 Gy to clinical target volume, respectively. The dose and dose volume parameters were evaluated for target, organs at risk, and normal tissue. Physical dose was converted to dose based on 2-Gy fractions (equivalent dose in 2 Gy per fraction, EQD 2 ) for comparison of 3 techniques. HDR and LDR significantly reduced the dose to rectum and bladder compared with VMAT. The D mean (EQD 2 ) of rectum decreased 22.36 Gy in HDR and 17.01 Gy in LDR from 30.24 Gy in VMAT, respectively. The D mean (EQD 2 ) of bladder decreased 6.91 Gy in HDR and 2.53 Gy in LDR from 13.46 Gy in VMAT. For the femoral heads and normal tissue, the mean doses were also significantly reduced in both HDR and LDR compared with VMAT. For the urethra, the mean dose (EQD 2 ) was 80.26, 70.23, and 104.91 Gy in VMAT, HDR, and LDR brachytherapy, respectively. For localized prostate cancer, both HDR and LDR brachytherapy were clearly superior in the sparing of rectum, bladder, femoral heads, and normal tissue compared with VMAT. HDR provided the advantage in sparing of urethra compared with VMAT and LDR.

  11. Effects of gamma radiation in annatto seeds

    Energy Technology Data Exchange (ETDEWEB)

    Franco, Camilo F. de Oliveira, E-mail: camilo.urucum@hotmail.com [Empresa Brasileira de Pesquisa Agropecuaria (EMBRAPA/EMEPA), Joao Pessoa, PB (Brazil); Arthur, Valter; Arthur, Paula B., E-mail: arthur@cena.usp.br [Centro de Energia Nuclear na Agricultura (CENA/USP), Piracicaba, SP (Brazil); Harder, Marcia N.C., E-mail: marcia.harder@fatec.sp.gov.br [Centro Paula Souza, Curso Superior de Tecnologia em Bicombustiveis (FATEC), Piracicaba, SP (Brazil); Filho, Jose C.; Neto, Miguel B., E-mail: jorgecazefilho@yahoo.com.br [Empresa Estadual de Pesquisa Agropecuaria da Paraiba (EMEPA), Joao Pessoa, PB (Brazil)

    2015-07-01

    The annatto bixin has emerged as a major source of natural dyes used in the world notably by the substitution of synthetics harmful to human health and ecologic tendency in obtaining industrial products free of additives with applications in industries textiles; cosmetics; pharmaceutical and food mainly. The aim of this research was to obtain increased of germination rate and dormancy breaking on annatto seeds by gamma radiation. Annatto dry seeds were exposed to low doses of gamma radiation from source of Cobalt-60, type Gammecell-220, at 0.456 kGy/hour dose rate. In order to study stimulation effects of radiation on germination rate and dormancy breaking in the seeds. Five treatments with gamma radiation doses were applied as follows: 0 (control); 100; 125; 150 and 175 Gy. After irradiation the annatto seeds were planted as for usual seed production. According to the results obtained in this experiment we can conclude that the low doses of gamma radiation utilized on the annatto seeds did not presented significantly effect on the germination of plants. But the best dose to increase the germination of seeds was 150 Gy. (author)

  12. Effects of gamma radiation in annatto seeds

    International Nuclear Information System (INIS)

    Franco, Camilo F. de Oliveira; Arthur, Valter; Arthur, Paula B.; Harder, Marcia N.C.; Filho, Jose C.; Neto, Miguel B.

    2015-01-01

    The annatto bixin has emerged as a major source of natural dyes used in the world notably by the substitution of synthetics harmful to human health and ecologic tendency in obtaining industrial products free of additives with applications in industries textiles; cosmetics; pharmaceutical and food mainly. The aim of this research was to obtain increased of germination rate and dormancy breaking on annatto seeds by gamma radiation. Annatto dry seeds were exposed to low doses of gamma radiation from source of Cobalt-60, type Gammecell-220, at 0.456 kGy/hour dose rate. In order to study stimulation effects of radiation on germination rate and dormancy breaking in the seeds. Five treatments with gamma radiation doses were applied as follows: 0 (control); 100; 125; 150 and 175 Gy. After irradiation the annatto seeds were planted as for usual seed production. According to the results obtained in this experiment we can conclude that the low doses of gamma radiation utilized on the annatto seeds did not presented significantly effect on the germination of plants. But the best dose to increase the germination of seeds was 150 Gy. (author)

  13. Relationship between isotope half-life and prostatic edema for optimal prostate dose coverage in permanent seed implants

    International Nuclear Information System (INIS)

    Villeneuve, Maxime; Leclerc, Ghyslain; Lessard, Etienne; Pouliot, Jean; Beaulieu, Luc

    2008-01-01

    The robustness of treatment planning to prostatic edema for three different isotopes ( 125 I, 103 Pd, and 131 Cs) is explored using dynamical dose calculations on 25 different clinical prostate cases. The treatment plans were made using the inverse planning by simulated annealing (IPSA) algorithm. The prescription was 144, 127, and 125 Gy for 125 I, 131 Cs, and 103 Pd, respectively. For each isotope, three dose distribution schemes were used to impose different protection levels to the urethra: V 120 =0%, V 150 =0%, and V 150 =30%. Eleven initial edema values were considered ranging from 1.0 (no edema) to 2.0 (100%). The edema was assumed to resolve exponentially with time. The prostate volume, seed positions, and seed activity were dynamically tracked to produce the final dose distribution. Edema decay half-lives of 10, 30, and 50 days were used. A total of 675 dynamical calculations were performed for each initial edema value. For the 125 I isotope, limiting the urethra V 120 to 0% leads to a prostate D 90 under 140 Gy for initial edema values above 1.5. Planning with urethra V 150 at 0% provides a good response to the edema; the prostate D 90 remains higher than 140 Gy for edema values up to 1.8 and a half-life of 30 days or less. For 103 Pd, the prostate D 90 is under 97% of the prescription dose for approximately 66%, 40%, and 30% of edema values for urethra V 120 =0%, V 150 =0%, and V 150 =30%, respectively. Similar behavior is seen for 131 Cs and the center of the prostate becomes 'cold' for almost all edema scenarios. The magnitude of the edema following prostate brachytherapy, as well as the half-life of the isotope used and that of the edema resorption, all have important impacts on the dose distribution. The 125 I isotope with its longer half-life is more robust to prostatic edema. Setting up good planning objectives can provide an adequate compromise between organ doses and robustness. This is even more important since seed misplacements will contribute

  14. Dose rate constant and energy spectrum of interstitial brachytherapy sources

    International Nuclear Information System (INIS)

    Chen Zhe; Nath, Ravinder

    2001-01-01

    In the past two years, several new manufacturers have begun to market low-energy interstitial brachytherapy seeds containing 125 I and 103 Pd. Parallel to this development, the National Institute of Standards and Technology (NIST) has implemented a modification to the air-kerma strength (S K ) standard for 125 I seeds and has also established an S K standard for 103 Pd seeds. These events have generated a considerable number of investigations on the determination of the dose rate constants (Λ) of interstitial brachytherapy seeds. The aim of this work is to study the general properties underlying the determination of Λ and to develop a simple method for a quick and accurate estimation of Λ. As the dose rate constant of clinical seeds is defined at a fixed reference point, we postulated that Λ may be calculated by treating the seed as an effective point source when the seed's source strength is specified in S K and its source characteristics are specified by the photon energy spectrum measured in air at the reference point. Using a semi-analytic approach, an analytic expression for Λ was derived for point sources with known photon energy spectra. This approach enabled a systematic study of Λ as a function of energy. Using the measured energy spectra, the calculated Λ for 125 I model 6711 and 6702 seeds and for 192 Ir seed agreed with the AAPM recommended values within ±1%. For the 103 Pd model 200 seed, the agreement was 5% with a recently measured value (within the ±7% experimental uncertainty) and was within 1% with the Monte Carlo simulations. The analytic expression for Λ proposed here can be evaluated using a programmable calculator or a simple spreadsheet and it provides an efficient method for checking the measured dose rate constant for any interstitial brachytherapy seed once the energy spectrum of the seed is known

  15. On determining dose rate constants spectroscopically

    International Nuclear Information System (INIS)

    Rodriguez, M.; Rogers, D. W. O.

    2013-01-01

    Purpose: To investigate several aspects of the Chen and Nath spectroscopic method of determining the dose rate constants of 125 I and 103 Pd seeds [Z. Chen and R. Nath, Phys. Med. Biol. 55, 6089–6104 (2010)] including the accuracy of using a line or dual-point source approximation as done in their method, and the accuracy of ignoring the effects of the scattered photons in the spectra. Additionally, the authors investigate the accuracy of the literature's many different spectra for bare, i.e., unencapsulated 125 I and 103 Pd sources. Methods: Spectra generated by 14 125 I and 6 103 Pd seeds were calculated in vacuo at 10 cm from the source in a 2.7 × 2.7 × 0.05 cm 3 voxel using the EGSnrc BrachyDose Monte Carlo code. Calculated spectra used the initial photon spectra recommended by AAPM's TG-43U1 and NCRP (National Council of Radiation Protection and Measurements) Report 58 for the 125 I seeds, or TG-43U1 and NNDC(2000) (National Nuclear Data Center, 2000) for 103 Pd seeds. The emitted spectra were treated as coming from a line or dual-point source in a Monte Carlo simulation to calculate the dose rate constant. The TG-43U1 definition of the dose rate constant was used. These calculations were performed using the full spectrum including scattered photons or using only the main peaks in the spectrum as done experimentally. Statistical uncertainties on the air kerma/history and the dose rate/history were ⩽0.2%. The dose rate constants were also calculated using Monte Carlo simulations of the full seed model. Results: The ratio of the intensity of the 31 keV line relative to that of the main peak in 125 I spectra is, on average, 6.8% higher when calculated with the NCRP Report 58 initial spectrum vs that calculated with TG-43U1 initial spectrum. The 103 Pd spectra exhibit an average 6.2% decrease in the 22.9 keV line relative to the main peak when calculated with the TG-43U1 rather than the NNDC(2000) initial spectrum. The measured values from three different

  16. Effects of radioactive 125I seeds on A549 cell line and human embryonic lung diploid cell line 2BS cultivated in vitro and assessment of its clinical safety dose

    International Nuclear Information System (INIS)

    Bian Wenchao; Qi Liangchen

    2012-01-01

    Objective: To observe the cell count changes of A549 cell line and human embryonic lung diploid cell line 2BS after irradiated by 125 I seeds with different doses, and to study the growth inhibition of 125 I on this two kinds of cell lines, and to determine its clinical safety dose in treatment of non-small cell lung. Methods: 125 I seeds with different doses (low dose: 0.2 mCi, mediate dose: 0.4 mCi, high dose: 0.8 mCi) were chosen and put into A549 cells and human embryonic lung diploid cell line 2BS in vitro, the cells on the 2nd, 4th, 6th and 8th days after irradiation were collected, the alive cells were counted by cells dyeing experiments, then the growth curves were drawn, and the IC 50 of the radioactive 125 I seeds to both two cell lines were calculated. Results: Compared with blank and control groups, the cell proliferation trend of A549 cells in low dose group was not significantly influenced (P>0.05), but the growth of A549 cells in mediate and high dose groups were inhibited in a time-dependent manner, there were significant differences (P<0.05), the most obvious change was on the 6th day. The IC 50 of the radioactive 125 I seeds to A549 cells was about .04 mCi. While the growth inhibition of 125 I 2BS had no statistically significant differences between various dose groups (P>0.05), and the IC 50 of the radioactive 125 I seeds to 2BS cell line was about 1.65 mCi. Conclusion: 0.4 mCi of radioactive 125 I seeds has already had the obvious damage effect on A549 cell, 0.8 mCi of radioactive 125 I seeds has the stronger effect. The IC 50 of the radioactive 125 I seeds to 2BS cells is about 1.65 mCi, so the clinical safety dosage is 0.4-0.8 mCi. (authors)

  17. Intercomparison On Depth Dose Measurement

    International Nuclear Information System (INIS)

    Rohmah, N; Akhadi, M

    1996-01-01

    Intercomparation on personal dose evaluation system has been carried out between CSRSR-NAEA of Indonesia toward Standard Laboratory of JAERI (Japan) and ARL (Australia). The intercomparison was in 10 amm depth dose measurement , Hp (10), from the intercomparison result could be stated that personal depth dose measurement conducted by CSRSR was sufficiently good. Deviation of dose measurement result using personal dosemeter of TLD BG-1 type which were used by CSRSR in the intercomparison and routine photon personal dose monitoring was still in internationally agreed limit. Maximum deviation of reported doses by CSRSR compared to delivered doses for dosemeter irradiation by JAERI was -10.0 percent and by ARL was +29 percent. Maximum deviation permitted in personal dose monitoring is ± 50 percent

  18. Isodose curves recorded in radiochromic film of an iodine seed array

    International Nuclear Information System (INIS)

    Mourao, Arnaldo Prata; Tomaz, Lucas Crusoe; Grynberg, Suely Epzstein

    2015-01-01

    Brachytherapy seeds are frequently used in cancer treatment. Iodine seeds are ranked among the top choices when it comes to the treatment of prostate cancer. Iodine-125 emits X and gamma photons with an average energy of 28 keV and a half-life of 59.4 days. A set of four iodine-125 seeds, model 6711 produced by Amersham Health, were used in this work. The dosimetric characteristics for a seed were obtained taking into account the recommendations of TG-43 protocol, developed by the AAPM (American Association of Physicists in Medicine). To realize the experiment three plates of Standard Grade Solid Water, model 457 ® Gammex were used. One solid water plate was machined for accommodate the seed set. The set of seeds was placed in a symmetrical configuration trying to simulate an arrangement which may occur in vivo during treatment. A radiochromic film sheet was placed on the plate machined after the seed charge. The machined plate charged and with the film sheet was placed between two others solid water plate to recorder the radiation dose. The machined plate was placed between the other two plates for better reliability in measurements. The radio chromic film was irradiated by an equivalent X-ray beam using the reference radiation RQR 3 IEC (International Electrotechnical Commission) with different doses (0.5 to 1.0 Gy) to obtain the calibration curve in the dose region measured. After validation of the methodology, the study of the interaction between the radiation fields of the set of seeds became possible and the survey of isodose curves of these setting was conducted. (author)

  19. Physical Methods for Seed Invigoration: Advantages and Challenges in Seed Technology.

    Science.gov (United States)

    Araújo, Susana de Sousa; Paparella, Stefania; Dondi, Daniele; Bentivoglio, Antonio; Carbonera, Daniela; Balestrazzi, Alma

    2016-01-01

    In the context of seed technology, the use of physical methods for increasing plant production offers advantages over conventional treatments based on chemical substances. The effects of physical invigoration treatments in seeds can be now addressed at multiple levels, ranging from morpho-structural aspects to changes in gene expression and protein or metabolite accumulation. Among the physical methods available, "magneto-priming" and irradiation with microwaves (MWs) or ionizing radiations (IRs) are the most promising pre-sowing seed treatments. "Magneto-priming" is based on the application of magnetic fields and described as an eco-friendly, cheap, non-invasive technique with proved beneficial effects on seed germination, vigor and crop yield. IRs, as γ-rays and X-rays, have been widely regarded as a powerful tool in agricultural sciences and food technology. Gamma-rays delivered at low dose have showed to enhance germination percentage and seedling establishment, acting as an actual 'priming' treatment. Different biological effects have been observed in seeds subjected to MWs and X-rays but knowledge about their impact as seed invigoration agent or stimulatory effects on germination need to be further extended. Ultraviolet (UV) radiations, namely UV-A and UV-C have shown to stimulate positive impacts on seed health, germination, and seedling vigor. For all mentioned physical treatments, extensive fundamental and applied research is still needed to define the optimal dose, exposition time, genotype- and environment-dependent irradiation conditions. Electron paramagnetic resonance has an enormous potential in seed technology not fully explored to monitor seed invigoration treatments and/or identifying the best suitable irradiation dose or time-point to stop the treatment. The present manuscript describes the use of physical methods for seed invigoration, while providing a critical discussion on the constraints and advantages. The future perspectives related to

  20. Physical Methods for Seed Invigoration: Advantages and Challenges in Seed Technology

    Science.gov (United States)

    Araújo, Susana de Sousa; Paparella, Stefania; Dondi, Daniele; Bentivoglio, Antonio; Carbonera, Daniela; Balestrazzi, Alma

    2016-01-01

    In the context of seed technology, the use of physical methods for increasing plant production offers advantages over conventional treatments based on chemical substances. The effects of physical invigoration treatments in seeds can be now addressed at multiple levels, ranging from morpho-structural aspects to changes in gene expression and protein or metabolite accumulation. Among the physical methods available, “magneto-priming” and irradiation with microwaves (MWs) or ionizing radiations (IRs) are the most promising pre-sowing seed treatments. “Magneto-priming” is based on the application of magnetic fields and described as an eco-friendly, cheap, non-invasive technique with proved beneficial effects on seed germination, vigor and crop yield. IRs, as γ-rays and X-rays, have been widely regarded as a powerful tool in agricultural sciences and food technology. Gamma-rays delivered at low dose have showed to enhance germination percentage and seedling establishment, acting as an actual ‘priming’ treatment. Different biological effects have been observed in seeds subjected to MWs and X-rays but knowledge about their impact as seed invigoration agent or stimulatory effects on germination need to be further extended. Ultraviolet (UV) radiations, namely UV-A and UV-C have shown to stimulate positive impacts on seed health, germination, and seedling vigor. For all mentioned physical treatments, extensive fundamental and applied research is still needed to define the optimal dose, exposition time, genotype- and environment-dependent irradiation conditions. Electron paramagnetic resonance has an enormous potential in seed technology not fully explored to monitor seed invigoration treatments and/or identifying the best suitable irradiation dose or time-point to stop the treatment. The present manuscript describes the use of physical methods for seed invigoration, while providing a critical discussion on the constraints and advantages. The future perspectives

  1. Physical methods for seed vigourization: advantages and challenges in seed technology

    Directory of Open Access Journals (Sweden)

    Susana eAraújo

    2016-05-01

    Full Text Available In the context of seed technology, the use of physical methods for increasing plant production offers advantages over conventional treatments based on chemical substances. The effects of physical vigourization treatments in seeds can be now addressed at multiple levels, ranging from morpho-structural aspects to changes in gene expression and protein or metabolite accumulation. Among the physical methods available, magneto-priming and irradiation with microwaves or ionizing radiations are the most promissory pre-sowing seed treatments. Magneto-priming is based on the application of magnetic fields and described as an eco-friendly, cheap, non-invasive technique with proved beneficial effects on seed germination, vigour and crop yield. Ionizing radiations, as gamma-rays and X-rays, have been widely regarded as a powerful tool in agricultural sciences and food technology. Gamma-rays delivered at low dose have showed to enhance germination percentage and seedling establishment, acting as an actual ‘priming’ treatment. Different biological effects have been observed in seeds subjected to microwaves and X-rays but knowledge about their impact as seed vigourization agent or stimulatory effects on germination need to be further extended. Ultraviolet (UV radiations, namely UV-A and UV-C have shown to stimulate positive impacts on seed health, germination and seedling vigour. For all mentioned physical treatments, extensive fundamental and applied research is still needed to define the optimal dose, exposition time, genotype- and environment-dependent irradiation conditions. Electron paramagnetic resonance (EPR has an enormous potential in seed technology not fully explored to monitor seed vigourization treatments and/or identifying the best suitable irradiation dose or time-point to stop the treatment. The present manuscript describes the use of physical methods for seed vigourization, while providing a critical discussion on the constraints and

  2. The preservation of lotus seeds by irradiation technique

    International Nuclear Information System (INIS)

    Lan Junming; Tang Chuandao

    1990-08-01

    The preservation test results of lotus seeds by gamma-ray irradiation technique are introduced. The results showed that the sitophilus, penicillus and aspergillus oryzae caused the great damage of lotus seeds. It was found that the radiation doses of deactivation for the insects and the mould were 0.8 kGy and 5 kGy respectively. The irradiated seeds packaged in the cloth bags and stored in the storehouse were not damaged by the insects and moulds for three years. The measured resutls also showed that the nutrient compositions were not changed and the pathogenic bacteria were not found. The irradiated lotus seeds are healthy and safe to the people

  3. Effect of seed treatment with static magnetic field (SMF) and low dose gamma radiation (GR) on grain yield of aerobic rice

    International Nuclear Information System (INIS)

    Kumar, Dinesh; Anand, Anjali; Singh, Bhupinder

    2014-01-01

    Aerobic rice cultivation is gaining popularity as it demands less water. However, poor germination of rice is an important issue in this situation. Seed pretreatment with static magnetic field (SMF) and gamma radiation (GR) at prescribed dose is known to influence the germination, seedling vigour and and yield of many crops. There is a possibility to improve the crop establishment under aerobic situation by physical seed treatment with static-magnetic field (SMF) and gamma radiation (GR) prior to sowing. Hence, a field experiment was conducted at the Indian Agricultural Research Institute, New Delhi during kharif 2012 and 2013 to study the effect of SMF and GR-treated seeds on growth and yield of aerobic rice. The five seed treatments were: SMF 50 mT for 2 hrs, SMF 100 mT for 2 hrs, GR 0.0025 kGy, GR 0.10 kGy and an untreated control. The experiment was laid out in a Randomized Block Design with four replications. Crop (variety 'Pusa Basmati-1121') was direct seeded on 25 th and 24 th June during 2012 and 2013, respectively at a spacing of 25 cm. Treatments GR 0.0025 kGy, SMF (50 mT) and SMF (100 mT) resulted in a significant improvement in grain yield of rice over control and GR dose (0.10 kGy) during both the years. Averaged across two years the grain yield increase by treating the rice seeds with GR 0.0025 kGy, SMF (50 mT) and SMF (100 mT) was 20.1, 17.6 and 14.5%, respectively over the control. Increase in GR dose (0.10 kGy ) was not effective in improving the yield, and was found to be similar to control. It is therefore concluded that treatment of rice seeds either with GR (0.0025 kGy) or SMF (50 mT) holds a great promise in increasing the grain yield of aerobic rice. (author)

  4. SU-E-T-378: Evaluation of An Analytical Model for the Inter-Seed Attenuation Effect in 103-Pd Multi-Seed Implant Brachytherapy

    Energy Technology Data Exchange (ETDEWEB)

    Safigholi, H; Soliman, A; Song, W [Sunnybrook Research Institute, Sunnybrook Health Sciences Centre, U of T, Toronto, Ontario (Canada); Meigooni, A Soleimani [Comprehensive Cancer Center of Nevada, Las Vegas, Nevada (United States); Han, D [Sunnybrook Research Institute, Sunnybrook Health Sciences Centre, U of T, Toronto, Ontario (Canada); University of California, San Diego, La Jolla, CA (United States)

    2015-06-15

    Purpose: Brachytherapy treatment planning systems based on TG-43 protocol calculate the dose in water and neglects the heterogeneity effect of seeds in multi-seed implant brachytherapy. In this research, the accuracy of a novel analytical model that we propose for the inter-seed attenuation effect (ISA) for 103-Pd seed model is evaluated. Methods: In the analytical model, dose perturbation due to the ISA effect for each seed in an LDR multi-seed implant for 103-Pd is calculated by assuming that the seed of interest is active and the other surrounding seeds are inactive. The cumulative dosimetric effect of all seeds is then summed using the superposition principle. The model is based on pre Monte Carlo (MC) simulated 3D kernels of the dose perturbations caused by the ISA effect. The cumulative ISA effect due to multiple surrounding seeds is obtained by a simple multiplication of the individual ISA effect by each seed, the effect of which is determined by the distance from the seed of interest. This novel algorithm is then compared with full MC water-based simulations (FMCW). Results: The results show that the dose perturbation model we propose is in excellent agreement with the FMCW values for a case with three seeds separated by 1 cm. The average difference of the model and the FMCW simulations was less than 8%±2%. Conclusion: Using the proposed novel analytical ISA effect model, one could expedite the corrections due to the ISA dose perturbation effects during permanent seed 103-Pd brachytherapy planning with minimal increase in time since the model is based on multiplications and superposition. This model can be applied, in principle, to any other brachytherapy seeds. Further work is necessary to validate this model on a more complicated geometry as well.

  5. Effects of gamma radiation in tomato seeds

    International Nuclear Information System (INIS)

    Wiendl, Toni A.; Wiendl, Fritz W.; Franco, Suely S.H.; Franco, Jose G.; Althur, Valter; Arthur, Paula B.

    2013-01-01

    Tomato dry seeds of the hybrid 'Gladiador' F1 were exposed to low doses of gamma radiation from Co-60 source at 0,509 kGy tax rate in order to study stimulation effects of radiation on germination and plant growth. Eight treatments radiation doses were applied as follows: 0 (control); 2,5; 5,0; 7,5; 10,0; 12,5; 15,0; 20,0 Gy. Seed germination as well as green fruits number, harvested fruit number, fruit weight and total production were assessed to identify occurrence of stimulation. Tomato seeds and plants were handled as for usual tomato production in Brazil. Low doses of gamma radiation treatment in the seeds stimulate germination and substantially increase fruit number and total production up to 86% at 10 Gy dose. There are evidences that the use of low doses of gamma radiation can stimulate germination and plant production thus, showing hormetic effects. (author)

  6. Electron beam irradiation: laboratory and field studies of cowpea seeds

    International Nuclear Information System (INIS)

    Srinivasan, K.; Chauhan, S.K.; Prasad, T.V.; Pramod, R.; Verma, V.P.; Petwal, V.; Dwivedi, J.; Bhalla, S.

    2015-01-01

    Cowpea (Vigna unguiculata) rich in protein and vitamins is emerging as one of the most important food legumes to tackle malnutrition. Pulse beetles (Callosobruchus chinensis and C. maculatus) are the pests of economic importance causing enormous losses during storage. Although various pest management strategies exist for the control of these pests, environmental concerns necessitate developing ecofriendly strategies. Electron beam (EB) irradiation has the potential to be a viable, non-chemical, residue-free strategy for management of pulse beetles during storage, but higher doses affect seed germination and viability. Hence, the present investigation was taken up to analyse the dosage effect of the irradiation on seed attributes of cowpea. Healthy cowpea seeds were irradiated with low energy electrons at different doses viz., 180, 360, 540, 720, 900, 1080, 1260, 1440 and 1620 Gy at 500 keV using the EB Accelerator facility at Raja Ramanna Centre for Advanced Technology, Indore. EB irradiated seeds were tested for physiological viz., germination, seedling vigour and vigour index and biochemical parameters viz., electrical conductivity of seed leachate, seed viability/tetrazolium test and dehydrogenase activity. Germination and vigour of the irradiated seeds were evaluated as per the ISTA Rules (ISTA, 1996). Vigour index was calculated as the product of germination percentage and seedling vigour. About 3,000 irradiated seeds from each dose were grown in the field at the Experimental farm, National Bureau of Plant Genetic Resources, New Delhi. Seeds harvested from 1500 individual plants of M 1 generation from each dose (50 seeds from each plant individually) were sown in next season and observed for chlorophyll mutations, if any. Results revealed that doses upto 1080 Gy (88%) did not affect the germination of cowpea seeds drastically as compared to untreated seeds (98%). Lower doses viz., 180 and 360 Gy had no impact on vigour components while higher doses (1080 Gy

  7. Monte Carlo investigation of I-125 interseed attenuation for standard and thinner seeds in prostate brachytherapy with phantom validation using a MOSFET.

    Science.gov (United States)

    Mason, J; Al-Qaisieh, B; Bownes, P; Henry, A; Thwaites, D

    2013-03-01

    In permanent seed implant prostate brachytherapy the actual dose delivered to the patient may be less than that calculated by TG-43U1 due to interseed attenuation (ISA) and differences between prostate tissue composition and water. In this study the magnitude of the ISA effect is assessed in a phantom and in clinical prostate postimplant cases. Results are compared for seed models 6711 and 9011 with 0.8 and 0.5 mm diameters, respectively. A polymethyl methacrylate (PMMA) phantom was designed to perform ISA measurements in a simple eight-seed arrangement and at the center of an implant of 36 seeds. Monte Carlo (MC) simulation and experimental measurements using a MOSFET dosimeter were used to measure dose rate and the ISA effect. MC simulations of 15 CT-based postimplant prostate treatment plans were performed to compare the clinical impact of ISA on dose to prostate, urethra, rectum, and the volume enclosed by the 100% isodose, for 6711 and 9011 seed models. In the phantom, ISA reduced the dose rate at the MOSFET position by 8.6%-18.3% (6711) and 7.8%-16.7% (9011) depending on the measurement configuration. MOSFET measured dose rates agreed with MC simulation predictions within the MOSFET measurement uncertainty, which ranged from 5.5% to 7.2% depending on the measurement configuration (k = 1, for the mean of four measurements). For 15 clinical implants, the mean ISA effect for 6711 was to reduce prostate D90 by 4.2 Gy (3%), prostate V100 by 0.5 cc (1.4%), urethra D10 by 11.3 Gy (4.4%), rectal D2cc by 5.5 Gy (4.6%), and the 100% isodose volume by 2.3 cc. For the 9011 seed the mean ISA effect reduced prostate D90 by 2.2 Gy (1.6%), prostate V100 by 0.3 cc (0.7%), urethra D10 by 8.0 Gy (3.2%), rectal D2cc by 3.1 Gy (2.7%), and the 100% isodose volume by 1.2 cc. Differences between the MC simulation and TG-43U1 consensus data for the 6711 seed model had a similar impact, reducing mean prostate D90 by 6 Gy (4.2%) and V100 by 0.6 cc (1.8%). ISA causes the delivered dose

  8. Dose-response of seeds of the parasitic weeds Striga and Orobanche toward the synthetic germination stimulants GR24.

    NARCIS (Netherlands)

    Wigchert, S.C.M.; Kuiper, E.; Boelhouwer, G.J.; Nefkens, G.H.L.; Verkley, J.A.C.; Zwanenburg, B.

    1999-01-01

    Striga and Orobanche seeds germinate in response to a host-derived germination stimulant. Dose-response curves of the synthetic strigolactone analogues GR 24 and Nijmegen 1 were determined, and their activities were compared to that of the naturally occurring stimulant sorgolactone. Typical

  9. Results of irradiation of vegetable seeds before sowing

    Energy Technology Data Exchange (ETDEWEB)

    Daskalov, Kh; Maltseva, S [Bylgarska Akademiya na Naukite, Sofia. Tsentralna Lab. po Obshta Genetika

    1980-01-01

    Effect of low dose /sup 60/Co ..gamma..-irradiation upon seeds of tomatoes, pepper and egg-plants has been investigated for 10 years. It is established that low doses of irradiation stimulate the seeds sprouting, development of plants as a result of the seeds irradiated and early ripeness of the plants.

  10. Effects of gamma radiation in tomato seeds

    Energy Technology Data Exchange (ETDEWEB)

    Wiendl, Toni A.; Wiendl, Fritz W.; Franco, Suely S.H.; Franco, Jose G.; Althur, Valter, E-mail: tawiendl@hotmail.com, E-mail: gilmita@uol.com.br [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), Sao Paulo, SP (Brazil); Arthur, Paula B., E-mail: arthur@cena.usp.br [Centro de Energia Nuclear na Agricultura (CENA/USP), Piracicaba, SP (Brazil)

    2013-07-01

    Tomato dry seeds of the hybrid 'Gladiador' F1 were exposed to low doses of gamma radiation from Co-60 source at 0,509 kGy tax rate in order to study stimulation effects of radiation on germination and plant growth. Eight treatments radiation doses were applied as follows: 0 (control); 2,5; 5,0; 7,5; 10,0; 12,5; 15,0; 20,0 Gy. Seed germination as well as green fruits number, harvested fruit number, fruit weight and total production were assessed to identify occurrence of stimulation. Tomato seeds and plants were handled as for usual tomato production in Brazil. Low doses of gamma radiation treatment in the seeds stimulate germination and substantially increase fruit number and total production up to 86% at 10 Gy dose. There are evidences that the use of low doses of gamma radiation can stimulate germination and plant production thus, showing hormetic effects. (author)

  11. Gamma radiation of cotton seeds pre-planting

    International Nuclear Information System (INIS)

    Gulyamov, M-K.; Atadzhanov, M.; Narimov, S.

    1977-01-01

    The study of pre-planting irradiation of the cotton plant seeds with gamma rays is summed up. It is for the first time that for the industrial grades stimulating doses for preplanting gamma irradiation of seeds have been offered depending on the power of a radiation source, time before planting, reproduction and the site of origin of seeds. In the Tashkent area doses stimulating the growth, development, and productivity of the cotton plant G. hirsutum L. for seeds, resting in the dry condition are 0.5-2 krad by Co 60 gamma-rays. The early maturing kinds of the type C-4727 should be irradiated with slightly lowered doses (0.5-1 krad) while the usual types of the kind 108-F require doses nearer to 2 krad. Time from irradiation of the seed to planting influences not only the character of changes in the plants, but also heredity. Study during the vegetation period shows that at a dose of 1 krad a much earlier maturity (by 2 days) is observed for irradiation 10 days before planting. Irradiation 20 days before planting shows considerable delay in maturing and productivity as compared to controls

  12. Monte Carlo-aided dosimetry of the new Bebig IsoSeed registered 103Pd Interstitial Brachytherapy Seed

    International Nuclear Information System (INIS)

    Daskalov, George M.; Williamson, J.F.

    2001-01-01

    A new model 103 Pd interstitial brachytherapy source, the IsoSeed registered 103 Pd, was recently introduced by Bebig Isotopentechnik und Umweltdiagnostik GmbH for permanent implant applications. This study presents the first quantitative theoretical study of the seed's dosimetric quantities. Monte Carlo photon transport (MCPT) simulation techniques have been used to evaluate the dose-rate distributions around the model IsoSeed registered 103 Pd source in liquid water and air phantoms. These results have been used to calculate and tabulate the anisotropy function, F(r,θ), radial dose function, g(r), and anisotropy factors, φ(r), and dose-rate constant as defined by AAPM Task Group 43 (TG-43) Report. Cartesian 'away' and 'along' tables, giving the dose rates per unit air-kerma strength in water in the range 0.1-3 cm distance around the seed have also been tabulated. The dose-rate constant, Λ, was evaluated by simulating the wide-angle, free-air chamber (WAFAC) calibration geometry recently implemented by NIST (National Institute of Standards and Technology) to realize the primary standard of air-kerma strength (S K,N99 ) for low-energy photon-emitting brachytherapy sources. The dose-rate constant has been found to be Λ=0.660±0.017 in units of dose-rate per unit air-kerma strength (cGy·h-1·U-1)

  13. Biostimulant on faveiro (Dimorphandra mollis Benth. seeds and seedling vigor

    Directory of Open Access Journals (Sweden)

    Tathiana Elisa Masetto

    2012-06-01

    Full Text Available This work aimed to verify the effects of biostimulant doses, applied through seeds, on faveiro (Dimorphandra mollis Benth. seeds and seedlings vigor. Seeds were previously sulfuric acid scarified in two consecutive years experiments. On 2006 August (first experiment seeds were submitted on Stimulate®: 0; 3.5; 7.0; 10.5 and 14 mL.0.5 Kg-1 doses (first experiment; and seeds picked in August, 2007, were Stimulate:0; 15; 20 and 25 mL.0.5Kg-1 of seeds treated (second experiment. After the biostimulant treatment seeds were sowed in cells trays containing 1:1 (v:v distroferric red latosol + plantmax®. The effect of different Stimulate® doses on Dimorphandra mollis seeds collected in different years were evaluated on the emergency percentage, speed emergency index, root length, aerial part height and dry seedling weight. It was conducted on entirely casualized with four repetitions of 25 seeds each treatment. The 14 mL (2006 lot and 15 mL (2007 lot 0.5Kg-1 of seeds doses provided larger percentage (50% and 66%, respectively and speed emergency indexes (0.67 and 0.9 respectively. The 20 mL.0.5Kg-1 of seeds dose treatment favored the aerial part length, but it didn't influenced the other Dimorphandra mollis seedlings vigor indexes.

  14. Evaluation of material heterogeneity dosimetric effects using radiochromic film for COMS eye plaques loaded with 125I seeds (model I25.S16)

    International Nuclear Information System (INIS)

    Acar, Hilal; Chiu-Tsao, Sou-Tung; Özbay, İsmail; Kemikler, Gönül; Tuncer, Samuray

    2013-01-01

    Purpose: (1) To measure absolute dose distributions in eye phantom for COMS eye plaques with 125 I seeds (model I25.S16) using radiochromic EBT film dosimetry. (2) To determine the dose correction function for calculations involving the TG-43 formalism to account for the presence of the COMS eye plaque using Monte Carlo (MC) method specific to this seed model. (3) To test the heterogeneous dose calculation accuracy of the new version of Plaque Simulator (v5.3.9) against the EBT film data for this seed model. Methods: Using EBT film, absolute doses were measured for 125 I seeds (model I25.S16) in COMS eye plaques (1) along the plaque's central axis for (a) uniformly loaded plaques (14–20 mm in diameter) and (b) a 20 mm plaque with single seed, and (2) in off-axis direction at depths of 5 and 12 mm for all four plaque sizes. The EBT film calibration was performed at 125 I photon energy. MC calculations using MCNP5 code for a single seed at the center of a 20 mm plaque in homogeneous water and polystyrene medium were performed. The heterogeneity dose correction function was determined from the MC calculations. These function values at various depths were entered into PS software (v5.3.9) to calculate the heterogeneous dose distributions for the uniformly loaded plaques (of all four sizes). The dose distributions with homogeneous water assumptions were also calculated using PS for comparison. The EBT film measured absolute dose rate values (film) were compared with those calculated using PS with homogeneous assumption (PS Homo) and heterogeneity correction (PS Hetero). The values of dose ratio (film/PS Homo) and (film/PS Hetero) were obtained. Results: The central axis depth dose rate values for a single seed in 20 mm plaque measured using EBT film and calculated with MCNP5 code (both in ploystyrene phantom) were compared, and agreement within 9% was found. The dose ratio (film/PS Homo) values were substantially lower than unity (mostly between 0.8 and 0.9) for all

  15. Do dose area product meter measurements reflect radiation doses ...

    African Journals Online (AJOL)

    Enrique

    SA JOURNAL OF RADIOLOGY • August 2004. Abstract. This study determined the correlation between radiation doses absorbed by health care workers and dose area product meter (DAP) measurements at Universitas Hospital, Bloemfontein. The DAP is an instrument which accurately measures the radiation emitted from ...

  16. Do dose area product meter measurements reflect radiation doses ...

    African Journals Online (AJOL)

    This study determined the correlation between radiation doses absorbed by health care workers and dose area product meter (DAP) measurements at Universitas Hospital, Bloemfontein. The DAP is an instrument which accurately measures the radiation emitted from the source. The study included the interventional ...

  17. Dose rate measuring device and dose rate measuring method using the same

    International Nuclear Information System (INIS)

    Urata, Megumu; Matsushita, Takashi; Hanazawa, Sadao; Konno, Takahiro; Chiba, Yoshinori; Yumitate, Tadahiro

    1998-01-01

    The device of the present invention comprises a scintillation fiber scope having a shape elongated in the direction of the height of a pressure vessel and emitting light by incident of radiation to detect radiation, a radioactivity measuring device for measuring a dose rate based on the detection of the fiber scope and a reel means for dispensing and taking up the fiber scope, and it constituted such that the dose rate of the pressure vessel and that of a shroud are determined independently. Then, when the taken out shroud is contained in an container, excessive shielding is not necessary, in addition, this device can reliably be inserted to or withdrawn from complicated places between the pressure vessel and the shroud, and further, the dose rate of the pressure vessel and that of the shroud can be measured approximately accurately even when the thickness of them is different greatly. (N.H.)

  18. Dose rate measuring device and dose rate measuring method using the same

    Energy Technology Data Exchange (ETDEWEB)

    Urata, Megumu; Matsushita, Takashi; Hanazawa, Sadao; Konno, Takahiro; Chiba, Yoshinori; Yumitate, Tadahiro

    1998-11-13

    The device of the present invention comprises a scintillation fiber scope having a shape elongated in the direction of the height of a pressure vessel and emitting light by incident of radiation to detect radiation, a radioactivity measuring device for measuring a dose rate based on the detection of the fiber scope and a reel means for dispensing and taking up the fiber scope, and it constituted such that the dose rate of the pressure vessel and that of a shroud are determined independently. Then, when the taken out shroud is contained in an container, excessive shielding is not necessary, in addition, this device can reliably be inserted to or withdrawn from complicated places between the pressure vessel and the shroud, and further, the dose rate of the pressure vessel and that of the shroud can be measured approximately accurately even when the thickness of them is different greatly. (N.H.)

  19. Dosimetric comparison of interactive planned and dynamic dose calculated prostate seed brachytherapy

    International Nuclear Information System (INIS)

    Meijer, Gert J.; Berg, Hetty A. van den; Hurkmans, Coen W.; Stijns, Pascal E.; Weterings, Jan H.

    2006-01-01

    Purpose: To compare the dosimetrical results of an interactive planning procedure and a procedure based on dynamic dose calculation for permanent prostate brachytherapy. Materials and methods: Between 6/2000 and 11/2005, 510 patients underwent 125 I implants for T1-T2 prostate cancer. Before 4/2003, 187 patients were treated using an interactive technique that included needle updating. After that period, 323 patients were treated with a more refined dynamic technique that included constant updating of the deposited seed position. The comparison is based on postimplant dose-volume parameters such as the V 100 and d 90 for the target, V 100 r for the rectum and d 10 u for the urethra. Furthermore, the target volume ratios (TVR=V 100 body /V 100 ), and the homogeneity indices (HI=[V 100 -V 150 ]/V 100 ) were calculated as additional quality parameters. Results: The dose outside the target volume was significantly reduced, the V 100 r decreased from 1.4cm 3 for the interactive technique to 0.6cm 3 for the dynamic technique. Similarly the mean TVR reduced from 1.66 to 1.44. In addition, the mean V 100 increased from 92% for the interactive procedure to 95% for the dynamic procedure. More importantly, the percentage of patients with a V 100 10 u (136% vs. 140%) and the HI (0.58 vs. 0.51). Conclusion: The dynamic implant procedure resulted in improved implants. Almost ideal dose coverage was achieved, while minimizing the dose outside the prostate

  20. Patient dose measurement and dose reduction in East Anglia (UK)

    International Nuclear Information System (INIS)

    Wade, J.P.; Goldstone, K.E.; Dendy, P.P.

    1995-01-01

    At the end of 1990 a programme of patient dose measurements was introduced as part of the quality assurance service already provided for X ray departments throughout the East Anglian Health Region (UK). Thermoluminescence dosemeters (TLDs) were used to measure over 1200 skin entrance surface doses for four common radiographic views in 33 hospitals in both the NHS and private sector. The four views were chosen to cover a wide range of equipment and techniques. The data collected have enabled Regional reference doses to be set which, for all views considered, fall below the National Radiological Protection Board (NRPB) Reference levels. In departments which exceeded reference levels, techniques were reviewed, improvements suggested and doses re-measured, in accordance with the recommended procedure for patient dose audit. A significant finding was that, given appropriate controls, X ray departments in the private sector could achieve the same acceptably low doses as NHS departments. (Author)

  1. Indução do florescimento e produção de sementes de alface com diferentes doses de ácido giberélico Flowering induction and seed yield in lettuce with different doses of gibberellic acid

    Directory of Open Access Journals (Sweden)

    Marie Yamamoto Reghin

    2000-11-01

    ser indicado a dose de 23 ppm.Doses of gibberellic acid (0, 10, 20 and 40 ppm in three lettuce bolting-resistant cultivars (Marisa, Verônica and Elisa were tested with the aim to induce flowering and seed yield. The experimental design was a complete randomized block, with four replications in a 4 x 3 factorial scheme. The sowing was done on 27/05/98 and the transplanting on 24/06/98, with the plants at the stage of 4 - 5 leaves. The application was performed only once at the stage of 10-12 leaves, using the product Pro-Gibb (ABBOTT, with 10% of gibberellic acid. The lettuce crop was managed accordingly to the usual recommendation. Seeds were harvested based on the physiological maturity and the harvest ranged from 02/12 to 21/12. There were evaluated the number of days to anthesis, number and height of stem flowering, flowering percentage, seed yield, weight of 1,000 seeds and percentage of seed germination. Flowering earliness was different among cultivars being Elisa the most precocious, regardless of gibberellic acid application and followed by 'Verônica' and 'Marisa'. The effect of doses had statistical significance on cv. Verônica and Marisa, being the highest flovering percentage at the dose of 28 ppm for the cv. Verônica and 35 ppm for 'Marisa'. However, superior seed yield was observed at the dose of 23 ppm in both cultivars. On the other hand seed production from 'Elisa' was significantly superior than from the other two cultivars, being the highest seed production observed on the control, (without application of gibberellic acid. Gibberellic acid increased the flowering percentage, earliness of the anthesis, seed maturation and seed yield, but the response depended on the cultivar; the later or more resistant to bolting the more pronounced were the effects of the gibberellic acid being recommended a dose of 23 ppm.

  2. Radioactive ceramic seeds with Ho-166 and Sm-153 with perspective of use in brachytherapy

    International Nuclear Information System (INIS)

    Valente, Eduardo Sarmento

    2010-01-01

    rates calculated at a distance of one meter ranged between 0.081 and 0.159.μS/h.seed. The results showed that the ceramic seeds produced have physical and chemical characteristics suitable for the proposed use in brachytherapy as small dimensions, appropriate concentration of target atoms of samarium and holmium or no dispersal of radioactive material in body fluid during the first ten days of immersion. The experiments also showed that the concentration of these elements in the ceramic matrix is sufficient to be activated in low neutron flux reactors, generating sufficient radioactivity for brachytherapy in high dose rates. The results obtained in vitro experiments were encouraging and demonstrated the ability that seeds, with β-emitting elements, have to eliminate tumor cells. The range of β radiation in biological experiments in vitro was consistent with the theoretical value and may be used as reference for the seed spacing when implanted in vivo. The solubility characteristics of radioactive nuclides in simulated body fluid in the short and long term, demonstrated that in the early days, there is no measurable solubilization. Indications were obtained that the seed dissolves measurably after a few months immersed in simulated body fluid. Finally it could be seen that the radioactive ceramic seeds with β emitters have favorable perspectives for use in high dose rate brachytherapy. (author)

  3. Effect of pre-sowing gamma-irradiation (Cs-137) of alfalfa seeds on fodder and seed yield

    International Nuclear Information System (INIS)

    Georgiev, Z.; Topchieva, A.; Michev, G.; Simeonova, L.; Stoyanov, S.

    1983-01-01

    The study was carried out at the experimental base of the Fodder Institute of Feeds, Pleven, with alfalfa cv. Pleven 6 in three field trials. The effect of pre-sowing gamma-irradiation (Cs-137) of air dry seeds at rates of 1000, 1300 and 1600 R on the yield produced was studied in the first trial (1980-1982). The effect of pre-sowing gamma-irradiation (Cs-137) of the seeds on seed production was studied in the second trial. Gamma-ray doses of 500, 1000 and 1500 R and three sowing rates (3, 5 and 10 kg/ha) were tested. The after effect of gamma-irradiation on the progeny was studied in the first trial (1981-1982). It was found that the treatment tested had a stimulating effect on seed production yields. Highest stimulating effect for the period of investigation, on the average, was observed with the 1500 R dose and the 3 kg/ha sowing rate. The same treatment produced highest net income. The gamma-ray doses tested had no radiation after-effect on the plant progeny. Sowing rates had a considerable effect on seed yield. In this respect the 3 kg/ha rate surpasses the 5 and 10 kg/ha rates by 6.00 and 19.64%, on the average. The 1000, 1300 and 1600 R gamma-ray doses had no stimulating effect on fodder yield

  4. Entrance and peripheral dose measurements during radiotherapy

    International Nuclear Information System (INIS)

    Sulieman, A.; Kappas, K.; Theodorou, K.

    2008-01-01

    In vivo dosimetry of entrance dose was performed using thermoluminescent dosimeters (TLD) in order to evaluate the clinical application of the build up caps in patient dose measurements and for different treatment techniques. Peripheral dose (thyroid and skin) was measured for patients during breast radiotherapy to evaluate the probability of secondary cancer induction. TLD-100 chips were used with different Copper build up caps (for 6 MV and 15 MV photon beams from two linear accelerators. Entrance doses were measured for patients during radiotherapy course for breast, head and neck, abdomen and pelvis malignancies. The measured entrance dose for the different patients for 6 MV beams is found to be within the ±2.6% compared to the dose derived from theoretical estimation (normalized dose at D max ). The same measurements for 15 MV beams are found to be ±3 %. The perturbation value can reach up to 20% of the D max , which acts as a limitation for entrance dose measurements. An average thyroid skin dose of 3.7% of the prescribed dose was measured per treatment session while the mean skin dose breast treatment session is estimated to be 42% of D max , for both internal and external fields. These results are comparable in those of the in vivo of reported in literature. The risk of fatality due to thyroid cancer per treatment course is 3x10 -3

  5. Mixed field dose equivalent measuring instruments

    International Nuclear Information System (INIS)

    Brackenbush, L.W.; McDonald, J.C.; Endres, G.W.R.; Quam, W.

    1985-01-01

    In the past, separate instruments have been used to monitor dose equivalent from neutrons and gamma rays. It has been demonstrated that it is now possible to measure simultaneously neutron and gamma dose with a single instrument, the tissue equivalent proportional counter (TEPC). With appropriate algorithms dose equivalent can also be determined from the TEPC. A simple ''pocket rem meter'' for measuring neutron dose equivalent has already been developed. Improved algorithms for determining dose equivalent for mixed fields are presented. (author)

  6. Dosimetric comparison of interactive planned and dynamic dose calculated prostate seed brachytherapy.

    Science.gov (United States)

    Meijer, Gert J; van den Berg, Hetty A; Hurkmans, Coen W; Stijns, Pascal E; Weterings, Jan H

    2006-09-01

    To compare the dosimetrical results of an interactive planning procedure and a procedure based on dynamic dose calculation for permanent prostate brachytherapy. Between 6/2000 and 11/2005, 510 patients underwent (125)I implants for T1-T2 prostate cancer. Before 4/2003, 187 patients were treated using an interactive technique that included needle updating. After that period, 323 patients were treated with a more refined dynamic technique that included constant updating of the deposited seed position. The comparison is based on postimplant dose - volume parameters such as the V(100) and d(90) for the target, V(100)(r) for the rectum and d(10)(u) for the urethra. Furthermore, the target volume ratios (TVR identical with V(100)(body)/V(100)), and the homogeneity indices (HI identical with [V(100)-V(150)]/V(100)) were calculated as additional quality parameters. The dose outside the target volume was significantly reduced, the V(100)(r) decreased from 1.4 cm(3) for the interactive technique to 0.6 cm(3) for the dynamic technique. Similarly the mean TVR reduced from 1.66 to 1.44. In addition, the mean V(100) increased from 92% for the interactive procedure to 95% for the dynamic procedure. More importantly, the percentage of patients with a V(100) < 80% reduced from 5% to 1%. A slight decline was observed with regard to the d(10)(u) (136% vs. 140%) and the HI (0.58 vs. 0.51). The dynamic implant procedure resulted in improved implants. Almost ideal dose coverage was achieved, while minimizing the dose outside the prostate.

  7. Effects of gamma radiation on freeze-dried wheat seeds

    International Nuclear Information System (INIS)

    Ajayi, N.O.; Larsson, B.

    1975-07-01

    The effect of radiation on freeze-dried wheat seeds are reported. The response of the various parts of the seedling to radiation was found to differ from one another. There was no significant modification of the effect of radiation on the shoot and root growth, while the growth of the coleoptile was slightly reduced in the frezze-dried seeds. The change in the shoot growth-absorbed dose relationship reported by others to occur at high doses for oven-dried as compared to air-dried barley seeds was not seen for the control and freeze-dried wheat seeds. The freeze-dried seeds are believed to show only the effect of radiation without any modification due to drying as such. The dose-effect relationships may be splited into functions characterised by different radiosensitivity. The high sensitivty effect is mainly taking place within the first 40 krad of energy absorption, and the low sensitivity is dominating at higher doses. (author)

  8. Use of low doses of cobalt 60 gamma radiation on beet (Beta vulgaris L.), carrot (Daucus carota L.) and radish (Raphanus sativus L.) seed to stimulate increase yield

    International Nuclear Information System (INIS)

    Bovi, Jose Eduardo

    2000-01-01

    The research had the aim of evaluating the effects of low doses of Cobalt-60 gamma radiation on seeds of radish (Raphanus sativus L.) cultiva Champion, cultivars Nantes Forto (european origin) and Brasilia (Rio Grande do Sul origin) carrot (Daucus carota L. var. sativus (Hoffm.) Thell), and red beet (Beta vulgaris L.) cultivar Tall Top Early Wonder before sowing, its effects on plant growth, on the yield and roots storage of two tillages: with sowing in the same day of radiation and six days after radiation seeds. The data showed that the seeds radiation did not interfered negatively on plants growth, and the species presented differences as roots production and doses on both plantation: radish with 5,0 Gy and 2,5 Gy doses respectively to the first and the second sowings, Brasilia carrot with 2,5 Gy dose to both sowings. Nantes carrot with 2,5 Gy and 5,0 Gy respectively to the first and the second sowings, and beet with 7,5 Gy and 5,0 Gy respectively to the first and the second plantations. There is not statistics difference by Tukey test (5% and 1%) and none relation between seeds radiation and loss weight on roots storage. (author)

  9. Automated treatment planning engine for prostate seed implant brachytherapy

    International Nuclear Information System (INIS)

    Yu Yan; Zhang, J.B.Y.; Brasacchio, Ralph A.; Okunieff, Paul G.; Rubens, Deborah J.; Strang, John G.; Soni, Arvind; Messing, Edward M.

    1999-01-01

    Purpose: To develop a computer-intelligent planning engine for automated treatment planning and optimization of ultrasound- and template-guided prostate seed implants. Methods and Materials: The genetic algorithm was modified to reflect the 2D nature of the implantation template. A multi-objective decision scheme was used to rank competing solutions, taking into account dose uniformity and conformity to the planning target volume (PTV), dose-sparing of the urethra and the rectum, and the sensitivity of the resulting dosimetry to seed misplacement. Optimized treatment plans were evaluated using selected dosimetric quantifiers, dose-volume histogram (DVH), and sensitivity analysis based on simulated seed placement errors. These dosimetric planning components were integrated into the Prostate Implant Planning Engine for Radiotherapy (PIPER). Results: PIPER has been used to produce a variety of plans for prostate seed implants. In general, maximization of the minimum peripheral dose (mPD) for given implanted total source strength tended to produce peripherally weighted seed patterns. Minimization of the urethral dose further reduced the loading in the central region of the PTV. Isodose conformity to the PTV was achieved when the set of objectives did not reflect seed positioning uncertainties; the corresponding optimal plan generally required fewer seeds and higher source strength per seed compared to the manual planning experience. When seed placement uncertainties were introduced into the set of treatment planning objectives, the optimal plan tended to reach a compromise between the preplanned outcome and the likelihood of retaining the preferred outcome after implantation. The reduction in the volatility of such seed configurations optimized under uncertainty was verified by sensitivity studies. Conclusion: An automated treatment planning engine incorporating real-time sensitivity analysis was found to be a useful tool in dosimetric planning for prostate

  10. The Comparison of Effects of Gamma Radiation of Crude Oil Yield on Some Sunflower (Helianthus Annuus Seeds

    Directory of Open Access Journals (Sweden)

    Havser ERTEM VAİZOĞULLAR

    2015-01-01

    Full Text Available This study compares the effects of different doses gamma radiation on crude oil yield and moisture of different six variety sunflower (Helianthus annuus L. seeds. As materials, sunflower variety Ege-2001, Turay, AS-508, Tunca, TR-3080 and Tarsan-1018 seeds were used and irradiated with doses of 0 (control, 100, 200, 300, 400 and 500 Gy gamma radiation. Irradiation was performed in a cesium (Ce137 Gammacell 3000 Elan source, dose rate about 9.75 Gy/min (2900 Ci in the Pamukkale University Faculty of Medicine in the department of the radiological. Moisture amount of seeds were also measured by AOCS standarts. Extraction of the seeds was done with soxhlet apparatus using petroleum ether by hot continuous extraction for 6 hours.  It was found that the highest moisture rate in 100 Gy for all seeds variety. The moisture rate ranged between 3.00 and 9.68% in TR-3080 and Ege-2001, respectively. According to the our results, seed moisture content was affected by gamma radiation in a significant negative one-way. The significant reduction in seed moisture content (9.68% began at 100 Gy of gamma rays and continued to decline to up to 4.04% at 500 Gy. The crude oil yield showed not a important increase in 100 and 200 Gy doses. The result showed that the highest crude oil yield was also obtained from 400 Gy and 33.49% in Ege-2001 seeds.

  11. Radioactive seed immobilization techniques for interstitial brachytherapy

    International Nuclear Information System (INIS)

    Yan, K.; Podder, T.; Buzurovic, I.; Hu, Y.; Dicker, A.; Valicenti, R.; Yu, Y.; Messing, E.; Rubens, D.; Sarkar, N.; Ng, W.

    2008-01-01

    In prostate brachytherapy, seeds can detach from their deposited sites and move locally in the pelvis or migrate to distant sites including the pulmonary and cardiac regions. Undesirable consequences of seed migration include inadequate dose coverage of the prostate and tissue irradiation effects at the site of migration. Thus, it is clinically important to develop seed immobilization techniques. We first analyze the possible causes for seed movement, and propose three potential techniques for seed immobilization: (1) surgical glue, (2) laser coagulation and (3) diathermy coagulation. The feasibility of each method is explored. Experiments were carried out using fresh bovine livers to investigate the efficacy of seed immobilization using surgical glue. Results have shown that the surgical glue can effectively immobilize the seeds. Evaluation of the radiation dose distribution revealed that the non-immobilized seed movement would change the planned isodose distribution considerably; while by using surgical glue method to immobilize the seeds, the changes were negligible. Prostate brachytherapy seed immobilization is necessary and three alternative mechanisms are promising for addressing this issue. Experiments for exploring the efficacy of the other two proposed methods are ongoing. Devices compatible with the brachytherapy procedure will be designed in future. (orig.)

  12. Irradiation of Egyptian Clover (Fahl) Seeds Resist The Growth of Dodder (Cuscuta Pedicellata)

    International Nuclear Information System (INIS)

    El-Enany, M.F; Zayed, E.M.; Abdel-Daem, G.A.N.A.

    2013-01-01

    Two experiments were conducted at Weed Research Laboratory wire green house, Agricultural Research Center, Egypt during 2011/ 2012. In the two experiments 100 pots 25 cm in diameter, In the first experiment series of Fahl treated with dodder in same rates. In the second experiment 100 seeds of Fahl ecotype with different dodder rates, 10, 20, 30 and 40 seeds (20 in each pot) were applied. Five doses were used .The 100 seeds of Fahl ecotype were subjected to the five gamma ray treatments,100, 150, 200, 250 and 300 Gray (gamma ray is cobalt Co 60 ), of atomic Energy Authority (AEA-Egypt). The isozymes analyses were used to measure variation in Fahl resistant to the infection by dodder. The RAPD-PCR using 10 primers. The aims of this study to induced mutations and measure the difference among doses in Fahl and response to tolerance dodder. In The results showed in the isozymes fractionation: can appear the variation among doses and infection of dodder, investigated the variation between dodder rates. As molecular study results showed the existence of differences between healthy and infected Fahl

  13. Resposta de sementes de amendoim a diferentes doses de radiação gama (60Co Response of peanut seeds to different levels of gamma radiation (60Co

    Directory of Open Access Journals (Sweden)

    Tatiana da S. Santos

    2010-10-01

    Full Text Available A radiação gama, proveniente da fonte de 60Co, é bastante utilizada para esterilização, visando a prevenção da decomposição e a toxidez de origem microbiana em diversos produtos. O grau de radiossensibilidade de um embrião vegetal depende da espécie, do estágio de seu desenvolvimento durante a radiação, da dose empregada e do critério usado para medir o efeito biológico, sendo comumente utilizado o teste de germinação. Objetivou-se, com este trabalho, estudar a sensibilidade do amendoim a radiação gama e seus efeitos na germinação, no vigor e na micoflora das sementes da cultivar BRS Havana, irradiadas com uma fonte de 60Co, tipo gammacell, com taxa de dosagem de 12,5 kGy h-1. As doses testadas em kGy foram as seguintes: 0; 0,5; 1,0; 1,5; 2,0; 2,5; 3,0; 6,0; 9,0; 12,0; 15,0; 18,0; 21,0 e 24,0. Com os resultados obtidos, concluiu-se que as doses acima de 3,0 kGy prejudicaram a viabilidade das sementes e as doses acima de 12 kGy comprometeram totalmente o vigor e a germinação das sementes de amendoim. A radiação a partir da dose 2,0 kGy eliminou os fungos Aspergillus flavus e Aspergillus niger e, a partir da dose 3,0 kGy, eliminou o Aspergillus glaucus. O Penicilium spp. permaneceu em mais de 30% das sementes em todos os tratamentos com radiação, não sendo eliminado até a dose de 24 kGy.The gamma radiation from 60Co source is widely used for sterilization aiming at preventing decomposition and toxicity from microbes in several products. The degree of radiosensitvity of a plant embryo depends on the species, the development stage during radiation, doses used and the criteria used to measure the biological effect, the germination test, being commonly used.This work aimed to study the peanut sensitivity to gamma radiation and its effects in the germination, in the vigour and seeds microflora of cultivar BRS Havana, irradiated with 60Co source, type gammacell with rate of dosage of 12.5 kGy h-1. The tested doses were the

  14. Seed counting system evaluation using arduino microcontroller

    Directory of Open Access Journals (Sweden)

    Paulo Fernando Escobar Paim

    2018-01-01

    Full Text Available The development of automated systems has been highlighted in the most diverse productive sectors, among them, the agricultural sector. These systems aim to optimize activities by increasing operational efficiency and quality of work. In this sense, the present work has the objective of evaluating a prototype developed for seed count in laboratory, using Arduino microcontroller. The prototype of the system for seed counting was built using a dosing mechanism commonly used in seeders, electric motor, Arduino Uno, light dependent resistor and light emitting diode. To test the prototype, a completely randomized design (CRD was used in a two-factorial scheme composed of three groups defined according to the number of seeds (500, 1000 and 1500 seeds tested, three speeds of the dosing disc that allowed the distribution in 17, 21 and 32 seeds per second, with 40 repetitions evaluating the seed counting prototype performance in different speeds. The prototype of the bench counter showed a moderate variability of seed number of counted within the nine tests and a high precision in the seed count on the distribution speeds of 17 and 21 seeds per second (s-1 up to 1500 seeds tested. Therefore, based on the observed results, the developed prototype presents itself as an excellent tool for counting seeds in laboratory.

  15. Dosimetry and treatment planning of Occu-Prosta 125I seeds for intraocular lesions

    International Nuclear Information System (INIS)

    Chaudhari, Suresh; Deshpande, Sudesh; Anand, Vivek; De, Sandeep; Kannan, V.; Saxena, Sanjay; Dash, A.; Basu, Mahua; Samant, Preetam

    2008-01-01

    Intraocular malignant lesions are frequently encountered in clinical practice. Plaque brachytherapy represents an effective means of treatment for intraocular lesions. Recently Radiopharmaceutical Division, BARC, Mumbai, has indigenously fabricated reasonable-cost 125 I sources. Here we are presenting the preliminary experience of dosimetry of sources, configuration of treatment planning system (TPS) and quality assurance (QA) for eye plaque therapy with Occu-Prosta 125 I seeds, treated in our hospital, for a patient with ocular lesions. 125 I seeds were calibrated using well-type chamber. BrachyVision TPS was configured with Monte Carlo computed radial dose functions and anisotropy functions for 125 I sources. Dose calculated by TPS at different points in central axis and off axis was compared with manually calculated dose. Eye plaque was fabricated of 17 karat pure gold, locally. The seeds were arranged in an outer ring near the edge of the plaque and in concentric rings throughout the plaque. The sources were manually digitized on the TPS, and dose distribution was calculated in three dimensions. Measured activity using cross-calibrated well-type chamber was within ± 10% of the activity specified by the supplier. Difference in TPS-calculated dose and manually calculated dose was within 5%. Treatment time calculated by TPS was in concordance with published data for similar plaque arrangement. (author)

  16. Brachytherapy dose measurements in heterogeneous tissues

    International Nuclear Information System (INIS)

    Paiva F, G.; Luvizotto, J.; Salles C, T.; Guimaraes A, P. C.; Dalledone S, P. de T.; Yoriyaz, H.; Rubo, R.

    2014-08-01

    Recently, Beau lieu et al. published an article providing guidance for Model-Based Dose Calculation Algorithms (MBDCAs), where tissue heterogeneity considerations are addressed. It is well-known that T G-43 formalism which considers only water medium is limited and significant dose differences have been found comparing both methodologies. The aim of the present work is to experimentally quantify dose values in heterogeneous medium using different dose measurement methods and techniques and compare them with those obtained with Monte Carlo simulations. Experiments have been performed using a Nucletron micro Selectron-Hdr Ir-192 brachytherapy source and a heterogeneous phantom composed by PMMA and different tissue equivalent cylinders like bone, lungs and muscle. Several dose measurements were obtained using tissue equivalent materials with height 1.8 cm and 4.3 cm positioned between the radiation source and the detectors. Radiochromic films, TLDs and MOSFET S have been used for the dose measurements. Film dosimetry has been performed using two methodologies: a) linearization for dose-response curve based on calibration curves to create a functional form that linearize s the dose response and b) 177 multichannel analysis dosimetry where the multiple color channels are analyzed allowing to address not only disturbances in the measurements caused by thickness variation in the film layer, but also, separate other external influences in the film response. All experiments have been simulated using the MCNP5 Monte Carlo radiation transport code. Comparison of experimental results are in good agreement with calculated dose values with differences less than 6% for almost all cases. (Author)

  17. Brachytherapy dose measurements in heterogeneous tissues

    Energy Technology Data Exchange (ETDEWEB)

    Paiva F, G.; Luvizotto, J.; Salles C, T.; Guimaraes A, P. C.; Dalledone S, P. de T.; Yoriyaz, H. [Instituto de Pesquisas Energeticas e Nucleares / CNEN, Av. Lineu Prestes 2242, Cidade Universitaria, 05508-000 Sao Paulo (Brazil); Rubo, R., E-mail: gabrielpaivafonseca@gmail.com [Hospital das Clinicas da Faculdade de Medicina da Universidade de Sao Paulo, 05403-900 Sao Paulo (Brazil)

    2014-08-15

    Recently, Beau lieu et al. published an article providing guidance for Model-Based Dose Calculation Algorithms (MBDCAs), where tissue heterogeneity considerations are addressed. It is well-known that T G-43 formalism which considers only water medium is limited and significant dose differences have been found comparing both methodologies. The aim of the present work is to experimentally quantify dose values in heterogeneous medium using different dose measurement methods and techniques and compare them with those obtained with Monte Carlo simulations. Experiments have been performed using a Nucletron micro Selectron-Hdr Ir-192 brachytherapy source and a heterogeneous phantom composed by PMMA and different tissue equivalent cylinders like bone, lungs and muscle. Several dose measurements were obtained using tissue equivalent materials with height 1.8 cm and 4.3 cm positioned between the radiation source and the detectors. Radiochromic films, TLDs and MOSFET S have been used for the dose measurements. Film dosimetry has been performed using two methodologies: a) linearization for dose-response curve based on calibration curves to create a functional form that linearize s the dose response and b) 177 multichannel analysis dosimetry where the multiple color channels are analyzed allowing to address not only disturbances in the measurements caused by thickness variation in the film layer, but also, separate other external influences in the film response. All experiments have been simulated using the MCNP5 Monte Carlo radiation transport code. Comparison of experimental results are in good agreement with calculated dose values with differences less than 6% for almost all cases. (Author)

  18. Traceability and standardization of large dose measurement

    International Nuclear Information System (INIS)

    Tanaka, Ryuichi

    1989-01-01

    The reliability of dose control for radiation sterilization and food irradiation depends on the relative errors in measurements made by different dosimeters and the level of process control techniques as well as traceability. International efforts have been made for standardization of dose measurement procedures and process control techniques. A system for traceability of large dose measurement has already been established in the U.S. and Britain, and it has become urgent in Japan to establish a traceability system. For process control for radiation sterilization of medical tools, dose measurement is replacing the use of a biological indicator to play a more important role in relation to sterilization assurance. AAMI is making efforts to establish implementation standards for process control for industrial sterilization with electron beam. In Japan, the Radiation Irradiation Promotion Association has developed a manual 'Measurement of Dose of Electron Beam for Irradiation' to be used by users of electron beam for irradiation. Further efforts are required to establish a proper traceability system and standardization of dose measurement. (N.K.)

  19. Predicting seed yield in perennial ryegrass using repeated canopy reflectance measurements and PLSR

    DEFF Research Database (Denmark)

    Gislum, René; Deleuran, Lise Christina; Boelt, Birte

    2009-01-01

    with first year seed crops using three sowing rates and three spring nitrogen (N) application rates. PLSR models were developed for each year and showed correlation coefficients of 0.71, 0.76, and 0.92, respectively. Regression coefficients showed in these experiments that the optimum time for canopy...... reflectance measurements was from approximately 600 cumulative growing degree-days (CGDD) to approximately 900 CGDD. This is the period just before and at heading of the seed crop. Furthermore, regression coefficients showed that information about N and water is important. The results support the development......Repeated canopy reflectance measurements together with partial least-squares regression (PLSR) were used to predict seed yield in perennial ryegrass (Lolium perenne L.). The measurements were performed during the spring and summer growing seasons of 2001 to 2003 in three field experiments...

  20. Ropes eye plaque brachytherapy dosimetry for two models of 103Pd seeds

    International Nuclear Information System (INIS)

    Saidi, P.; Sadeghi, M.; Shirazi, A.; Tenreiro, C.

    2011-01-01

    Full text: Brachytherapy dose distributions are calculated for I5 m m ROPES eye plaque loaded with model Theragenics200 and IR06-103Pd seeds. The effects of stainless steel backing and Acrylic insert on dose distribution along the central axis of the eye plaque and at critical ocular structure are investigated. Monte Carlo simulation was carried out with the Version 5 of the MCNP. The dose at critical ocular structure by considering the eye composition was calculated. Results are compared with the calculated data for CaMS eye plaque loaded with Theragenics200 palladium-103 seeds and model 6711 iodine-125 seed. The air kerma strength of the IR06- 103Pd seed to deliver 85 Gy in apex of tumor in water medium was calculated to be 4.10 U/seed. Along the central axis of stainless steel plaque loaded with new 103Pd seeds in Acrylic insert, the dose reduction relative to water is 6.9% at 5 mm (apex). Removal of the Acrylic insert from the plaque (replacing with water) did not make significantly difference in dose reduction results (O.2%). The presence of the stainless steel backing results in dose enhancement near the plaque relative to water. Doses at points of interest are higher for ROPES eye plaque when compared to CaMS eye plaque. The dosimetric parameters calculated in this work for the new palladium seed, showed that in dosimetry point of view, the IR06-103Pd seed is suitable for use in brachytherapy. The effect of Acrylic insert on dose distribution is negligible and the main effect on dose reduction is due to the presence of stainless steel plaque backing. (author)

  1. Effect of low doses of gamma radiation of Co-60 (radio-hormesis) in tomato seeds; Efeitos de baixas doses de radiacao gama do Co-60 (radio-hormesis) em sementes de tomate

    Energy Technology Data Exchange (ETDEWEB)

    Wiendl, Toni Andreas

    2010-07-01

    Tomato seeds of the Gladiador hybrid were exposed to gamma radiation of Co-60 with the following doses: 0; 2,5; 5; 7,5; 10; 12,5; 15 e 20 Gy. Analysis were performed on germination, seedlings height to cotyledon, seedling total height, seedling fresh and dry weight, plant height, stalk diameter at the root beginning, fresh and dry weight of the 5{sup th} leaf, number of green fruits with diameter higher than 3 cm, number of green, half ripen and ripen fruits, total number of fruits, Brix and pH of fruits, average fruit weight and fruit total production. A variety of stimulation effects were observed on the different plant developing stages. The greatest stimulus for production was observed in the 10 Gy dose. The highest seedling average height and plant average height were observed for the 7,5 Gy dose. The biggest number of green fruits with diameter higher than 3 cm occurred for the 12,5 and 15 Gy treatments. Irradiation also stimulated a higher total number of fruits in all doses, having advantage the 10 Gy dose which produced 88% more fruits than control as well as 86% more weight production. The fruits pH acidified significantly in a dose of 12,5 Gy and higher. Production increased in all treatments comparing to control and the highest stimulus for production observed was for the 10, 12,5 and 15 Gy. The use of low gamma radiation doses of Co-60 applied as pre-sowing treatment in the seeds, efficiently stimulated the development of plants and the tomato production. (author)

  2. Patient and personnel dose measurements at selective coronarangiography

    International Nuclear Information System (INIS)

    Maripuu, E.

    1977-01-01

    During 1975 dose measurements were performed on patients and doctors at the thoraxradiologic department of the Caroline Hospital in Stockholm, Sweden. The doses were measured during angiography. Skin doses are listed in tables. Also the doses to the bone marrow was estimated. LiF-dosemeters were used for the measurements. Calibration of the dosemeters and errors in the measurements are discussed

  3. Pine seeds radiosensitivity as depended upon their humidity and the term of storage after radiation exposure

    International Nuclear Information System (INIS)

    Porozova, O.A.

    1983-01-01

    The seeds of pine (Pinus silvestris L.) have been used to study the effect of average and so called ''low doses'' of ionizing radiation at different levels of seed humidity (3-4%-dried a little, 6-7%-aerially-dry and 9-10%-humid). The Seeds of every humidity level are irradiated in May in a rather wide dose range 0.5, 1, 2, 5, 10, 20, 30 Gy from a gamma source of 137 Cs at the dose rate of 0.96 Gy/min. After irradiation part of seeds was sown. It is shown that seeds with relatively high water content are more stable to the effect of gamma-radiation. The first indices of radiation injury in humid seeds (9-10% humidity) in the criteria of laboratory growing-out are noticed at the dose of 20 Gy while in dried seeds (3-4% hymidity) - at the dose of 2 Gy. Radiation injury of aerially-dried and dried seeds increases with the increase of radiation dose and periods of their storage. In humid seeds this effect depends on radiation dose alone; their storage for eight months did not produce a noticeable effect on growing-out

  4. A dynamic model for the estimation of optimum timing of computed tomography scan for dose evaluation of 125I or 103Pd seed implant of prostate

    International Nuclear Information System (INIS)

    Yue Ning; Dicker, Adam P.; Corn, Benjamin W.; Nath, Ravinder; Waterman, Frank M.

    1999-01-01

    Purpose/Objective: The dosimetric evaluation of permanent 125 I or 103 Pd prostate implant is based on the assumption that both prostate and seeds are static throughout the entire treatment time which lasts months. However, the prostate is often edematous after the surgical implantation of seeds. Therefore, both the volume of the prostate and the seed locations change dynamically as the edema resolves. This effect has impact on the validity of postimplant analysis based upon a CT scan. If a CT scan is taken too early after implantation while there is edema in the prostate, the dose delivered by the implant may be underestimated. If the imaging is delayed too long, the dose may be overestimated. The magnitude of this effect depends on both of the half-life of the isotope used and the half-life and magnitude of the edema. This study describes a dynamic biomathematical model which takes edema into account in calculating the dose delivered by the implant and is used to investigate the optimum time to obtain the postimplant CT scan. Materials and Methods: The dynamic biomathematical model is a numerical integration of the accumulated dose in which the prostate dimensions, the seed locations, and the source strength are all functions of time. The function which describes the change in prostate dimensions and seed locations as a function of time was determined in a separate study by analysis of serial postimplant CT scans. Dose-volume histograms (DVH) of the prostate for the total dose generated by the dynamic model are compared to DVHs generated by CT scans simulated for postimplant intervals ranging from 0 to 300 days after the implantation for 30 different combinations of the magnitude and duration of edema. Results: DVHs of the prostate calculated by taking edema into account show that the time of obtaining a CT scan for postimplant analysis is critical to the accuracy of dose evaluations. The comparison of the DVHs generated by the dynamic model to those generated by

  5. Antioxidant activity of extract from gamma irradiated red grape (Vitis vinifera) seeds

    International Nuclear Information System (INIS)

    Abdeldaiem, M. H.; Ali, H.G.M.; Nasr, E.H.

    2012-01-01

    This investigation aims to study the antioxidant activity efficiency of extracts from irradiated defatted red grape seeds at dose levels of 1, 3 and 5 kGy). The non-irradiated and irradiated defatted red grape seeds samples were extracted with acetone: water: acetic acid (90:9.5:0.5) immediately after irradiation and the antioxidant activity were studied. Gas chromatographic-Mass spectrum was applied to identify and quantify the phenolic compounds of extracts and the amino acids composition was determined in all samples under investigation of defatted red grape seeds. The measurements of the antioxidant activity, using a β-carotene-linoleate model system and radical scavenging capacity effect on 2, 2-diphenyl-1- picrylhydrazyl (DPPH) radical was determined in the extracts of defatted red grape seeds. The results indicated that extracts of defatted red grape seeds possess marked antioxidant activities, especially control samples compared with irradiated samples. The analysis by GC /MS led to identification of 41, 31, 33 and 28 components the of extract non-irradiated and irradiated samples at doses 1,3 and 5 kGy, respectively. It appears that grape seeds extract could be very effective in inhibiting lipid oxidation of sunflower oil. Thus, according to the results of this study, the extract of defatted red grape seeds may be used as a new potential source of natural antioxidant for food

  6. SU-E-T-259: Particle Swarm Optimization in Radial Dose Function Fitting for a Novel Iodine-125 Seed

    Energy Technology Data Exchange (ETDEWEB)

    Wu, X [University of Alabama at Birmingham, Birmingham, Al (United States); Duan, J; Popple, R; Huang, M; Shen, S; Brezovich, I [University of Alabama Birmingham, Birmingham, AL (United States); Cardan, R [UAB University of Alabama, Birmingham, Birmingham, AL (United States); Benhabib, S [University of Alabama at Birmingham, Birmingham, AL (United States)

    2014-06-01

    Purpose: To determine the coefficients of bi- and tri-exponential functions for the best fit of radial dose functions of the new iodine brachytherapy source: Iodine-125 Seed AgX-100. Methods: The particle swarm optimization (PSO) method was used to search for the coefficients of the biand tri-exponential functions that yield the best fit to data published for a few selected radial distances from the source. The coefficients were encoded into particles, and these particles move through the search space by following their local and global best-known positions. In each generation, particles were evaluated through their fitness function and their positions were changed through their velocities. This procedure was repeated until the convergence criterion was met or the maximum generation was reached. All best particles were found in less than 1,500 generations. Results: For the I-125 seed AgX-100 considered as a point source, the maximum deviation from the published data is less than 2.9% for bi-exponential fitting function and 0.2% for tri-exponential fitting function. For its line source, the maximum deviation is less than 1.1% for bi-exponential fitting function and 0.08% for tri-exponential fitting function. Conclusion: PSO is a powerful method in searching coefficients for bi-exponential and tri-exponential fitting functions. The bi- and tri-exponential models of Iodine-125 seed AgX-100 point and line sources obtained with PSO optimization provide accurate analytical forms of the radial dose function. The tri-exponential fitting function is more accurate than the bi-exponential function.

  7. Effect of mutagens on seed germination in chilli (Capsicum annuum L.)

    International Nuclear Information System (INIS)

    Dhamayanthi, K.P.M.; Reddy, V.R.K.

    2002-01-01

    Seeds of chilli variety CO-2 (Coimbatore-2) were irradiated with gamma rays ranging from 10 kR to 35 kR at an interval of 5 kR and the effect on seed germination, seedling survival, percent lethality and seedling injury were studied. Lower doses were stimulative, while higher doses had inhibitory effect on seed germination and seedling survival. The highest percentage of seed germination (37.5) and seedling survival (31.3) was recorded at 10 kR as compared to 28 percent of germination and 3.3 percent seedling survival in control. Percent lethality (9.6%) and seedling injury (6.5%) were comparatively low than the lethality percentage and seedling injury of the higher dose treatments. In chemical mutagen treatments, the maximum seed germination (54.5%) and seedling survival (51.2%), seedling lethality (0.97%) and seedling injury (1.37%) were obtained in the treated seeds of EMS at 0.5% concentration followed by 39.5% seed germination and 30.0% seedling survival, seedling lethality (3.8%) and seedling injury (3.06%) of MMS. The stimulative effect of seed germination is more in chemical mutagens than the physical mutagen. There was a proportionate decrease in germination percentage and seedling survival with an increase in dose/concentration of both the chemicals. (author)

  8. Dose calculation for permanent prostate implants incorporating spatially anisotropic linearly time-resolving edema

    International Nuclear Information System (INIS)

    Monajemi, T. T.; Clements, Charles M.; Sloboda, Ron S.

    2011-01-01

    Purpose: The objectives of this study were (i) to develop a dose calculation method for permanent prostate implants that incorporates a clinically motivated model for edema and (ii) to illustrate the use of the method by calculating the preimplant dosimetry error for a reference configuration of 125 I, 103 Pd, and 137 Cs seeds subject to edema-induced motions corresponding to a variety of model parameters. Methods: A model for spatially anisotropic edema that resolves linearly with time was developed based on serial magnetic resonance imaging measurements made previously at our center to characterize the edema for a group of n=40 prostate implant patients [R. S. Sloboda et al., ''Time course of prostatic edema post permanent seed implant determined by magnetic resonance imaging,'' Brachytherapy 9, 354-361 (2010)]. Model parameters consisted of edema magnitude, Δ, and period, T. The TG-43 dose calculation formalism for a point source was extended to incorporate the edema model, thus enabling calculation via numerical integration of the cumulative dose around an individual seed in the presence of edema. Using an even power piecewise-continuous polynomial representation for the radial dose function, the cumulative dose was also expressed in closed analytical form. Application of the method was illustrated by calculating the preimplant dosimetry error, RE preplan , in a 5x5x5 cm 3 volume for 125 I (Oncura 6711), 103 Pd (Theragenics 200), and 131 Cs (IsoRay CS-1) seeds arranged in the Radiological Physics Center test case 2 configuration for a range of edema relative magnitudes (Δ=[0.1,0.2,0.4,0.6,1.0]) and periods (T=[28,56,84] d). Results were compared to preimplant dosimetry errors calculated using a variation of the isotropic edema model developed by Chen et al. [''Dosimetric effects of edema in permanent prostate seed implants: A rigorous solution,'' Int. J. Radiat. Oncol., Biol., Phys. 47, 1405-1419 (2000)]. Results: As expected, RE preplan for our edema model

  9. Skin dose measurement with MICROSPEC-2 trademark

    International Nuclear Information System (INIS)

    Hsu, H.H.

    1997-01-01

    For many years, the Eberline HP-260 trademark beta detectors were used for skin dose measurements at Los Alamos National Laboratory. This detector does not measure the beta spectrum and the skin dose can only be determined if the contaminating radioactive isotope is known. A new product MICROSPEC-2 trademark, has been developed which consists of a small portable computer with a multichannel analyzer and a beta probe consisting of a phoswich detector. The system measures the beta spectrum and automatically folds in the beta fluence-to-dose conversion function to yield the skin dose

  10. Specific effects of small doses of 60Co-γ-radiation applied to the seeds before sowing on the yield of silo maize (small and large plot field experiments)

    International Nuclear Information System (INIS)

    Degner, W.; Schacht, W.; Koepp, R.

    1975-01-01

    Dry seeds of silo maize were cultivated under outside conditions after fractionated irradiation with low radiation doses. The yields of irradiated and unirradiated seeds were compared. The resistance of irradiated and unirradiated plants and ensilage were also studied and compared. The findings are discussed. (GSE/AK) [de

  11. Prediction of midline dose from entrance ad exit dose using OSLD measurements for total irradiation

    Energy Technology Data Exchange (ETDEWEB)

    Choi, Chang Heon; Park, Jong Min; Park, So Yeon; Chun, Min Soo; Han, Ji Hye; Cho, Jin Dong; Kim, Jung In [Dept. of Radiation Oncology, Seoul National University Hospital, Seoul (Korea, Republic of)

    2017-06-15

    This study aims to predict the midline dose based on the entrance and exit doses from optically stimulated luminescence detector (OSLD) measurements for total body irradiation (TBI). For TBI treatment, beam data sets were measured for 6 MV and 15 MV beams. To evaluate the tissue lateral effect of various thicknesses, the midline dose and peak dose were measured using a solid water phantom (SWP) and ion chamber. The entrance and exit doses were measured using OSLDs. OSLDs were attached onto the central beam axis at the entrance and exit surfaces of the phantom. The predicted midline dose was evaluated as the sum of the entrance and exit doses by OSLD measurement. The ratio of the entrance dose to the exit dose was evaluated at various thicknesses. The ratio of the peak dose to the midline dose was 1.12 for a 30 cm thick SWP at both energies. When the patient thickness is greater than 30 cm, the 15 MV should be used to ensure dose homogeneity. The ratio of the entrance dose to the exit dose was less than 1.0 for thicknesses of less than 30 cm and 40 cm at 6 MV and 15 MV, respectively. Therefore, the predicted midline dose can be underestimated for thinner body. At 15 MV, the ratios were approximately 1.06 for a thickness of 50 cm. In cases where adult patients are treated with the 15 MV photon beam, it is possible for the predicted midline dose to be overestimated for parts of the body with a thickness of 50 cm or greater. The predicted midline dose and OSLD-measured midline dose depend on the phantom thickness. For in-vivo dosimetry of TBI, the measurement dose should be corrected in order to accurately predict the midline dose.

  12. Development of Real-Time Measurement of Effective Dose for High Dose Rate Neutron Fields

    International Nuclear Information System (INIS)

    Braby, L. A.; Reece, W. D.; Hsu, W. H.

    2003-01-01

    Studies of the effects of low doses of ionizing radiation require sources of radiation which are well characterized in terms of the dose and the quality of the radiation. One of the best measures of the quality of neutron irradiation is the dose mean lineal energy. At very low dose rates this can be determined by measuring individual energy deposition events, and calculating the dose mean of the event size. However, at the dose rates that are normally required for biology experiments, the individual events can not be separated by radiation detectors. However, the total energy deposited in a specified time interval can be measured. This total energy has a random variation which depends on the size of the individual events, so the dose mean lineal energy can be calculated from the variance of repeated measurements of the energy deposited in a fixed time. We have developed a specialized charge integration circuit for the measurement of the charge produced in a small ion chamber in typical neutron irradiation experiments. We have also developed 4.3 mm diameter ion chambers with both tissue equivalent and carbon walls for the purpose of measuring dose mean lineal energy due to all radiations and due to all radiations except neutrons, respectively. By adjusting the gas pressure in the ion chamber, it can be made to simulate tissue volumes from a few nanometers to a few millimeters in diameter. The charge is integrated for 0.1 seconds, and the resulting pulse height is recorded by a multi channel analyzer. The system has been used in a variety of photon and neutron radiation fields, and measured values of dose and dose mean lineal energy are consistent with values extrapolated from measurements made by other techniques at much lower dose rates. It is expected that this technique will prove to be much more reliable than extrapolations from measurements made at low dose rates because these low dose rate exposures generally do not accurately reproduce the attenuation and

  13. Calculation of midplane dose for total body irradiation from entrance and exit dose MOSFET measurements.

    Science.gov (United States)

    Satory, P R

    2012-03-01

    This work is the development of a MOSFET based surface in vivo dosimetry system for total body irradiation patients treated with bilateral extended SSD beams using PMMA missing tissue compensators adjacent to the patient. An empirical formula to calculate midplane dose from MOSFET measured entrance and exit doses has been derived. The dependency of surface dose on the air-gap between the spoiler and the surface was investigated by suspending a spoiler above a water phantom, and taking percentage depth dose measurements (PDD). Exit and entrances doses were measured with MOSFETs in conjunction with midplane doses measured with an ion chamber. The entrance and exit doses were combined using an exponential attenuation formula to give an estimate of midplane dose and were compared to the midplane ion chamber measurement for a range of phantom thicknesses. Having a maximum PDD at the surface simplifies the prediction of midplane dose, which is achieved by ensuring that the air gap between the compensator and the surface is less than 10 cm. The comparison of estimated midplane dose and measured midplane dose showed no dependence on phantom thickness and an average correction factor of 0.88 was found. If the missing tissue compensators are kept within 10 cm of the patient then MOSFET measurements of entrance and exit dose can predict the midplane dose for the patient.

  14. THE THERAPEUTIC USE OF RADIOACTIVE GOLD SEEDS IN NEOPLASMS

    Energy Technology Data Exchange (ETDEWEB)

    Lachance, Paul; Vallee, A. F.

    1963-06-15

    A method and the apparatus for the treatment of neoplasms with Au/sup 198/ seeds are described. The introducer or gun is loaded with a magazine or cartridge containing 15 radioactive gold grains and then irradiated. The grains are cylinders made of gold encased in Pt with measurements of: length, 2.1 mm; diameter, 0.4 mm; weight, 25 mgm; platinum casing, 0.2 mm. The seeds are ready for use 7 to 10 days after irradiation or when gamma activity is around 3 to 4.5 mC per seed. A permanent implant gives to the tumor an approximate dose of 6000- 7000 r in 4 to 5 days. The effectiveness and advantages of the method are also discussed. (P.C.H.)

  15. Perennial soybean seeds coated with high doses of boron and zinc

    African Journals Online (AJOL)

    Lucas

    2016-09-14

    Sep 14, 2016 ... hot-air blower was switched on at the temperature of 40ºC for 2 min. As stuffing .... not a significant difference in this variable (p<0.05) between ... water content of the seeds after they are coated, and in. Figure 3 it is .... Germ ination / Em ergence (%. ) Germination. Dead seeds. Soaked seeds. Emergence a b.

  16. Problems in continuous dose rate measurement

    International Nuclear Information System (INIS)

    Yoshioka, Mitsuo

    1983-01-01

    The system of continuous dose rate measurement in Fukui Prefecture is described. A telemeter system was constructed in October, 1976, and it has been operated since 1977. Observation has been made at 11 observation stations in the Prefecture. In addition to the continuous measurement of dose rate by using NaI(T1)-DBM systems, the ionization chambers for high dose rate were installed, and also meteorological data have been collected. The detectors are covered with 1 mm thick aluminum designed so that the absorption of external radiation is kept as small as possible. To keep the environmental temperature of the detectors constant, constant temperature wind blow is made. With these consideration, the measurement of Xe-133 is possible, and the standard deviation of yearly dose is around 0.4 mR/Y. By measuring DBM transmission rate, the contribution of Xe-133, which comes from the exhaust pumps in power plants, can be detected. The problems of this system are as follows. First of all, the characteristics of the system must meet the purpose of dose monitoring. The system must detect the dose less than the target value to be achieved. The second is the selection of measuring systems to be set. The system is still not unified, and it is difficult to exchange data between different stations. Finally, the method of data analysis is not yet unified. Manuals or guide-books for this purpose are necessary for the mutual comparison of the data from the stations in different districts. (Kato, T.)

  17. ''Nonisolated-sensor'' solid polystyrene absorbed dose measurements

    International Nuclear Information System (INIS)

    Zeitz, L.; Laughlin, J.S.

    1982-01-01

    A ''nonisolated-sensor'' solid polystyrene calorimeter was constructed to test the role of thermal diffusion in limiting the length of irradiation time during which temperature measurements with nonisolated sensors could be made sufficiently free of drift for determining dose with radiation fields such as gamma rays, x rays, and high-energy electrons. From measured ratios of dose at 5.0 and 0.5 cm in polystyrene and comparisons to dose measurements with a polystyrene parallel-plate (pancake) ion chamber, it was shown that thermal diffusion is sufficiently small in polystyrene to permit accurate measurements for irradiation periods of less than 20 min. Comparison of the absorbed dose measurements and depth dose ratios with pancake ion chambers and calorimeter showed, that within the precision and accuracy of the two measuring systems, there is close agreement. The nonisolated-sensor solid polystyrene calorimeter has the interesting features of (i) simplicity of construction, (ii) simplicity of operation without vacuum or feedback for temperature control, (iii) capability of simultaneous measurements at several depths and off-axis positions, (iv) the very small thermal defect correction with polystyrene, and (v) operation with the calorimeter in any orientation

  18. Nonisolated-sensor solid polystyrene absorbed dose measurements

    International Nuclear Information System (INIS)

    Zeitz, L.; Laughlin, J.S.

    1982-01-01

    A nonisolated-sensor solid polystyrene calorimeter was constructed to test the role of thermal diffusion in limiting the length of irradiation time during which temperature measurements with nonisolated sensors could be made sufficiently free of drift for determining dose with radiation fields such as gamma rays, x rays, and high-energy electrons. From measured ratios of dose at 5.0 and 0.5 cm in polystyrene and comparisons to dose measurements with a polystyrene parallel-plate (pancake) ion chamber, it was shown that thermal diffusion is sufficiently small in polystyrene to permit accurate measurements for irradiation periods of less than 20 min. Comparison of the absorbed dose measurements and depth dose ratios with pancake ion chambers and calorimeter showed, that within the precision and accuracy of the two measuring systems, there is close agreement. The nonisolated-sensor solid polystyrene calorimeter has the interesting features of (i) simplicity of construction, (ii) simplicity of operation without vacuum or feedback for temperature control, (iii) capability of simultaneous measurements at several depths and off-axis positions, (iv) the very small thermal defect correction with polystyrene, and (v) operation with the calorimeter in any orientation

  19. Seeding of silicon by copper ion implantation for selective electroless copper plating

    Energy Technology Data Exchange (ETDEWEB)

    Bhansali, S.; Sood, D.K.; Zmood, R.B. [Microelectronic and Materials Technology Centre, Royal Melbourne Institute of Technolgy, Melbourne, VIC (Australia)

    1993-12-31

    We report on the successful use of copper(self) ion implantation into silicon to seed the electroless plating of copper on silicon (100) surfaces. Copper ions have been implanted to doses of 5E14-6.4E16 ions/cm{sup 2} using a MEEVA ion implanter at extraction voltage of 40kV. Dose was varied in fine steps to determine the threshold dose of 2E15 Cu ions/cm{sup 2} for `seed` formation of copper films on silicon using a commercial electroless plating solution. Plated films were studied with Rutherford backscattering spectrometry, scanning electron microscopy, EDX and profilometry . The adhesion of films was measured by `scotch tape test`. The adhesion was found to improve with increasing dose. However thicker films exhibited rather poor adhesion and high internal stress. SEM results show that the films grow first as isolated islands which become larger and eventually impinge into a continuous film as the plating time is increased. (authors). 5 refs., 1 tab., 3 figs.

  20. Seeding of silicon by copper ion implantation for selective electroless copper plating

    Energy Technology Data Exchange (ETDEWEB)

    Bhansali, S; Sood, D K; Zmood, R B [Microelectronic and Materials Technology Centre, Royal Melbourne Institute of Technolgy, Melbourne, VIC (Australia)

    1994-12-31

    We report on the successful use of copper(self) ion implantation into silicon to seed the electroless plating of copper on silicon (100) surfaces. Copper ions have been implanted to doses of 5E14-6.4E16 ions/cm{sup 2} using a MEEVA ion implanter at extraction voltage of 40kV. Dose was varied in fine steps to determine the threshold dose of 2E15 Cu ions/cm{sup 2} for `seed` formation of copper films on silicon using a commercial electroless plating solution. Plated films were studied with Rutherford backscattering spectrometry, scanning electron microscopy, EDX and profilometry . The adhesion of films was measured by `scotch tape test`. The adhesion was found to improve with increasing dose. However thicker films exhibited rather poor adhesion and high internal stress. SEM results show that the films grow first as isolated islands which become larger and eventually impinge into a continuous film as the plating time is increased. (authors). 5 refs., 1 tab., 3 figs.

  1. Seeding of silicon by copper ion implantation for selective electroless copper plating

    International Nuclear Information System (INIS)

    Bhansali, S.; Sood, D.K.; Zmood, R.B.

    1993-01-01

    We report on the successful use of copper(self) ion implantation into silicon to seed the electroless plating of copper on silicon (100) surfaces. Copper ions have been implanted to doses of 5E14-6.4E16 ions/cm 2 using a MEEVA ion implanter at extraction voltage of 40kV. Dose was varied in fine steps to determine the threshold dose of 2E15 Cu ions/cm 2 for 'seed' formation of copper films on silicon using a commercial electroless plating solution. Plated films were studied with Rutherford backscattering spectrometry, scanning electron microscopy, EDX and profilometry . The adhesion of films was measured by 'scotch tape test'. The adhesion was found to improve with increasing dose. However thicker films exhibited rather poor adhesion and high internal stress. SEM results show that the films grow first as isolated islands which become larger and eventually impinge into a continuous film as the plating time is increased. (authors). 5 refs., 1 tab., 3 figs

  2. The use of the Kelor Seeds (Moringa oleifera) as alternative coagulant in waste delivery process of textile industrial waste

    Science.gov (United States)

    Rambe, AM; Pandia, S.; Ginting, MHS; Tambun, R.; Haryanto, B.

    2018-02-01

    This research is to know the influence of moringa seed as coagulant, pH of liquid waste textile industry (jeans wash), size of moringa seed particles to decrease of turbidity percentage. Measurements were made to Total Suspended Solid, Color Rate and Chemical Oxygen Demand for wastewater textile industry by coagulation - flocculation method. Variables of this study were conducted on dosage of moringa, with particle size 212 mesh. The results showed that moringa seeds as coagulant dose optimum is 1250 mg/L for the textile industry wastewater at pH 7.8. Moringa seed powder is about 212 mesh with a dose of 1250 mg/L can lower the turbidity of 77.77%, Total Suspended Solid amounted to 83.69% and Chemical Oxygen Demand amounted to 75.86%.

  3. Evaluation of germination, vegetative development and genotoxicity of lettuce from irradiated seeds

    Energy Technology Data Exchange (ETDEWEB)

    Franco, Caio H.; Arthur, Valter, E-mail: caiohaddadfranco@lnbio.cnpem.com.br, E-mail: arthur@cena.usp.br [Centro de Energia Nuclear na Agricultura (CENA/USP), Piracicaba, SP (Brazil). Lab. de Radiobiologia e Ambiente; Silva, Regildo M.G. da, E-mail: regildo@assis.unesp.br [Universidade Estadual Paulista Julio de Mesquita Filho (UNESP), Assis, SP (Brazil). Fac. de Ciencias de Letras. Lab. de Fitoterapicos e Farmacologia; Franco, Jose G.; Franco, Suely S. H., E-mail: gilmita@uol.com.br, E-mail: zegilmar60@gmail.com [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), Sao Paulo, SP (Brazil)

    2013-07-01

    Agriculture has benefited from the use of radiation techniques, which provides plant varieties with distinguish characteristics, such as higher productivity, precocity and greater resistance to disease, pests and harsh weather conditions. Therefore, this study aimed on the analysis of greenhouse morphological development of Lactuca sativa originated from irradiated seeds; as well as test their genotoxic effect. The seeds were irradiated at doses of 25, 50, 75, 150 and 300 Gy. In order to determine the germination index, the number of seedlings emerged from each well was counted. Biometric and weight measurements were taken during the development and post-harvest stages. Genotoxicity tests were performed based on the biological assay Allium cepa. The results demonstrated that the best vegetative development was observed for individuals originated from seeds irradiated with doses of 25 and 50 Gy when compared with the control, while this dose did not differ significantly from 75 Gy The calculated germination index remained constant at all dosages. Inhibition of vegetative growth was observed on 150 and 300 Gy dosed individuals. It was also observed that the increasing rate of irradiation is inversely proportional to the mitotic index. A relationship can be established between increased levels of irradiation with increasing percentage of aberrant cells. (author)

  4. Evaluation of germination, vegetative development and genotoxicity of lettuce from irradiated seeds

    International Nuclear Information System (INIS)

    Franco, Caio H.; Arthur, Valter

    2013-01-01

    Agriculture has benefited from the use of radiation techniques, which provides plant varieties with distinguish characteristics, such as higher productivity, precocity and greater resistance to disease, pests and harsh weather conditions. Therefore, this study aimed on the analysis of greenhouse morphological development of Lactuca sativa originated from irradiated seeds; as well as test their genotoxic effect. The seeds were irradiated at doses of 25, 50, 75, 150 and 300 Gy. In order to determine the germination index, the number of seedlings emerged from each well was counted. Biometric and weight measurements were taken during the development and post-harvest stages. Genotoxicity tests were performed based on the biological assay Allium cepa. The results demonstrated that the best vegetative development was observed for individuals originated from seeds irradiated with doses of 25 and 50 Gy when compared with the control, while this dose did not differ significantly from 75 Gy The calculated germination index remained constant at all dosages. Inhibition of vegetative growth was observed on 150 and 300 Gy dosed individuals. It was also observed that the increasing rate of irradiation is inversely proportional to the mitotic index. A relationship can be established between increased levels of irradiation with increasing percentage of aberrant cells. (author)

  5. Radiation dose measurements

    International Nuclear Information System (INIS)

    1960-01-01

    About 200 scientists from 28 countries and 5 international organizations met at a symposium on radiation dosimetry held by the International Atomic Energy Agency in June 1960. The aim of the symposium was not so much the description of a large number of measuring instruments as a discussion of the methods used, with special emphasis on those problems which had become important in the context of recent developments, such as the measurement of mixed or very large doses

  6. A novel curvilinear approach for prostate seed implantation

    Energy Technology Data Exchange (ETDEWEB)

    Podder, Tarun K.; Dicker, Adam P.; Hutapea, Parsaoran; Darvish, Kurosh; Yu Yan [Department of Radiation Oncology, Leo Jenkins Cancer Center, Brody School of Medicine, East Carolina University, Greenville, North Carolina 27834 (United States); Department of Radiation Oncology, Kimmel Cancer Center, Jefferson Medical College, Thomas Jefferson University, Philadelphia, Pennsylvania 19107 (United States); Department of Mechanical Engineering, Temple University, Philadelphia, Pennsylvania 19122 (United States); Department of Radiation Oncology, Kimmel Cancer Center, Jefferson Medical College, Thomas Jefferson University, Philadelphia, Pennsylvania 19107 (United States)

    2012-04-15

    Purpose: A new technique called ''curvilinear approach'' for prostate seed implantation has been proposed. The purpose of this study is to evaluate the dosimetric benefit of curvilinear distribution of seeds for low-dose-rate (LDR) prostate brachytherapy. Methods: Twenty LDR prostate brachytherapy cases planned intraoperatively with VariSeed planning system and I-125 seeds were randomly selected as reference rectilinear cases. All the cases were replanned by using curved-needle approach keeping the same individual source strength and the volume receiving 100% of prescribed dose 145 Gy (V{sub 100}). Parameters such as number of needles, seeds, and the dose coverage of the prostate (D{sub 90}, V{sub 150}, V{sub 200}), urethra (D{sub 30}, D{sub 10}) and rectum (D{sub 5}, V{sub 100}) were compared for the rectilinear and the curvilinear methods. Statistical significance was assessed using two-tailed student's t-test. Results: Reduction of the required number of needles and seeds in curvilinear method were 30.5% (p < 0.001) and 11.8% (p < 0.49), respectively. Dose to the urethra was reduced significantly; D{sub 30} reduced by 10.1% (p < 0.01) and D{sub 10} reduced by 9.9% (p < 0.02). Reduction in rectum dose D{sub 5} was 18.5% (p < 0.03) and V{sub 100} was also reduced from 0.93 cc in rectilinear to 0.21 cc in curvilinear (p < 0.001). Also the V{sub 150} and V{sub 200} coverage of prostate reduced by 18.8% (p < 0.01) and 33.9% (p < 0.001), respectively. Conclusions: Significant improvement in the relevant dosimetric parameters was observed in curvilinear needle approach. Prostate dose homogeneity (V{sub 150}, V{sub 200}) improved while urethral dose was reduced, which might potentially result in better treatment outcome. Reduction in rectal dose could potentially reduce rectal toxicity and complications. Reduction in number of needles would minimize edema and thereby could improve postimplant urinary incontinence. This study indicates that the

  7. Phosphorus rates on yield and quality of lettuce seeds Doses de fósforo na produção e qualidade de sementes de alface

    Directory of Open Access Journals (Sweden)

    Cristiaini Kano

    2012-12-01

    Full Text Available Because of lack of information about phosphorus fertilization in lettuce from the standpoint of seed production, this study was undertaken. The work was carried out in Botucatu, São Paulo state, Brazil, from September 25, 2003 to February 19, 2004, in order to study the influence of crescents phosphorus rates on yield and quality of lettuce seeds, cultivar Verônica. The experimental design was randomized blocks with five treatments (0; 200; 400; 600 and 800 kg ha-1 of P2O5 and five replications. The following characteristics were evaluated: seed production per plant (g plant-1, number of seeds per plant and quality (percentage of germination and seed vigor. A linear increasing was observed on production and number of seeds per plant of lettuce with phosphorus rates, but these rates did not affect the seed physiological quality evaluated on weight of 1,000 seeds (average = 0.91 g, first count of germination (98%, standard germination test (99%, seed germination speed index (68.5, seedling emergence speed index (97.0 and emerged seedlings (49.3%.Este estudo foi conduzido devido à falta de informações sobre a adubação em plantas de alface do ponto de vista da produção de sementes. O trabalho foi conduzido em área da UNESP, em Botucatu, de 25/09/03 a 19/02/04 com o objetivo de avaliar a influência de doses crescentes de fósforo na produção e qualidade de sementes de alface, cultivar Verônica. O delineamento experimental utilizado foi blocos casualizados, com cinco tratamentos (0; 200; 400; 600 e 800 kg ha-1 de P2O5 e cinco repetições. Foram avaliadas as características de produção de sementes por planta (g planta-1, número de sementes por planta e a qualidade (percentagem de germinação e vigor de sementes. Foi observado aumento linear na produção e no número de sementes por planta com as doses de P2O5, mas estas doses não afetaram a qualidade fisiológica das sementes avaliada pela massa de mil sementes (média de 0,91 g

  8. Experimental determination of the anisotropy function for the Model 200 103Pd 'light seed' and derivation of the anisotropy constant based upon the linear quadratic model

    International Nuclear Information System (INIS)

    Yue Ning; Nath, Ravinder

    2002-01-01

    Since the publication of the AAPM Task Group 43 report in 1995, Model 200 103 Pd seed, which has been widely used in prostate seed implants and other brachytherapy procedures, has undergone some changes in its internal geometry resulting from the manufacturer's transition from lower specific activity reactor-produced 103 Pd ('heavy seeds') to higher specific activity accelerator-produced radioactive material ('light seeds'). Based on previously reported theoretical calculations and measurements, the dose rate constants and the radial dose functions of the two types of seeds are nearly the same and have already been reported. In this work, the anisotropy function of the 'light seed' was experimentally measured and an averaging method for the determination of the anisotropy constant from distance-dependent values of anisotropy factors is presented based upon the continuous low dose rate irradiation linear quadratic model for cell killing. The anisotropy function of Model 200 103 Pd 'light seeds' was measured in a Solid Water trade mark sign phantom using 1x1x1 mm micro LiF TLD chips at radial distances of 1, 2, 3, 4, 5, and 6 cm and at angles from 0 to 90 deg. with respect to the longitudinal axis of the seeds. At a radial distance of 1 cm, the measured anisotropy function of the 103 Pd 'light seed' is considerably lower than that of the 103 Pd 'heavy seed' reported in the TG 43 report. Our measured values at all radial distances are in excellent agreement with the results of a Monte Carlo simulation reported by Weaver, except for points along and near the seed longitudinal axis. The anisotropy constant of the 103 Pd 'light seed' was calculated using the linear quadratic biological model for cell killing in 30 clinical implants. For the model 200 ''light seed,'' it has a value of 0.865. However, our biological model calculations lead us to conclude that if the anisotropy factors of an interstitial brachytherapy seed vary significantly over radial distances anisotropy

  9. Exposure of treating physician to radiation during prostate brachytherapy using iodine-125 seeds. Dose measurements on both hands with thermoluminescence dosimeters

    International Nuclear Information System (INIS)

    Schiefer, Hans; Seelentag, Wolf; Plasswilm, Ludwig; Ries, Gerhard; Toggenburg, Friedrich von; Lenggenhager, Cornelius; Schmid, Hans-Peter; Leippold, Thomas; Engeler, Daniel; Prikler, Ladislav; Krusche, Bernd; Roth, Jakob

    2009-01-01

    Background and purpose: only sparse reports have been made about radiation exposure of the treating physician during prostate seed implantation. Therefore, thermoluminescence dosimeter (TLD) measurements on the index fingers and the backs of both hands were conducted. Material and methods: stranded iodine-125 seeds with a mean apparent activity of 27.4 MBq per seed were used. During application, the treating physician manipulated the loaded needle with the index fingers, partially under fluoroscopic control. Four physicians with varying experience treated 24 patients. The radiation exposure was determined with TLD-100 chips attached to the index fingertips and the backs of hands. Radiation exposure was correlated with the physician's experience. Results: the average brachytherapy duration by the most experienced physician was 19.2 min (standard deviation σ = 1.2 min; novices: 34.8 min [σ = 10.2 min]). The mean activity was 1,703 MBq (σ = 123 MBq), applied with 16.3 needles (σ = 2.5 needles; novices: 1,469 MBq [σ = 229 MBq]; 16.8 needles [σ = 2.3 needles ]). The exposure of the finger of the ''active hand'' and the back of the hand amounted to 1.31 mSv (σ = 0.54 mSv) and 0.61 mSv (σ = 0.23 mSv), respectively (novices: 2.07 mSv [σ = 0.86 mSv] and 1.05 mSv [σ = 0.53 mSv]). Conclusion: if no other radiation exposure needs to be considered, an experienced physician can perform about 400 applications per year without exceeding the limit of 500 mSv/year; for novices, the corresponding figure is about 200. (orig.)

  10. Development of Real-Time Measurement of Effective Dose for High Dose Rate Neutron Fields

    CERN Document Server

    Braby, L A; Reece, W D

    2003-01-01

    Studies of the effects of low doses of ionizing radiation require sources of radiation which are well characterized in terms of the dose and the quality of the radiation. One of the best measures of the quality of neutron irradiation is the dose mean lineal energy. At very low dose rates this can be determined by measuring individual energy deposition events, and calculating the dose mean of the event size. However, at the dose rates that are normally required for biology experiments, the individual events can not be separated by radiation detectors. However, the total energy deposited in a specified time interval can be measured. This total energy has a random variation which depends on the size of the individual events, so the dose mean lineal energy can be calculated from the variance of repeated measurements of the energy deposited in a fixed time. We have developed a specialized charge integration circuit for the measurement of the charge produced in a small ion chamber in typical neutron irradiation exp...

  11. The effect of low doses of gamma irradiation on common bunt and covered smut diseases in wheat and barley seeds (Tilletia Caries, T. Foetida and Ustilago Hordei)

    International Nuclear Information System (INIS)

    Mohammed, F.A.

    1991-12-01

    The aim of the present study was to investigate the effect of seeds treated by low doses of gamma irradiation (5-45 GY) in reducing the infection caused by pathagens transferred on wheat and barley seeds. Field experiments included 4 varieties of wheat (Mexipak, Fl. Aurore, Haurani, Jezira 17) and one variety of barley (WI 2291). Laboratory experiments were also carried out where fungal spores were germinated in soil-extract agar after the exposure to radiation. Field experiments included planting of irradiated seeds before and after inoculation, seed inculated by irradiated spores and seeds planted in soil contaminated by spores. In other experiments, irradiated seeds were planted after inoculation by spores of T. Caries and another time by the spores of T. Foetida. Results for 1988-89 and 1989-90 show that irradiation at doses used have a clear effect on reducing the infection by common bunt in wheat and covered smut in barley, where reductions reached between 15-60% compared with the control. The effects of 30 and 40 GY were more obvious. This study has also shown that the effect of radiation on the rate of infection (Mexipak, Fl. Aurore) was higher than in varieties which are more disease-resistent (Haurani, Jazira 17). Field and laboratory experiments indicate that this reduction in infection may be attributed to the effect of radiation on seeds and their germination and not on the fungi spores. There have been no significant differences between the rate of infection caused by T. Caries and T. Foetida after irradiation treatment. (author). 61 refs., 28 figs., 7 tabs

  12. Study on interstitial brachytherapy using 103Pd seeds on tumor-bearing rats

    International Nuclear Information System (INIS)

    Feng Huiru; Zhang Jingming; Tian Jiahe; Ding Weimin; Bai Hongsheng; Jin Xiaohai

    2003-01-01

    The effects of low-dose-rate brachytherapy are investigated in tumor-bearing rat. Walker 256 cells are transplanted subcutaneously with a trocar in the left leg of rats (Wistar). Two weeks later, rats with a tumor of 10 mm in mean diameter are divided into three groups (10 per group). Two groups are given 1 seed and 2 seeds implantation of 103 Pd, respectively, the third group is as an untreated control. Tumor size is measured twice a week until the 25th day when the rats are killed. Tumor is monitored either by palpation or further confirmed by histopathology. Kaplan-Meier statistic method is performed for survival analysis. The results show that the average weight of rats in untreated group is lower than in radiation groups (P 0.05). Tumor volumes in all treatment groups increase more obviously than in control till 16 days post-implantation. Tumor regression rate in 1 seed group is higher than in control group and in 2 seeds group. Although survival analysis show that the median survival time in 1 seed, 2 seeds and control groups are 24±0, 21±2 and 19±2 days with survival rate of 80%, 60% and 50% respectively, no significant differences are seen in all groups. So, brachytherapy with 103 Pd seed is effective on tumor-bearing rats. The implantation of seed can cause tumor edema in a self-limited way. A reasonable doses chosen for brachytherapy may play a role in treatment success

  13. Experimental dosimetry of Ho-166 bioglass seed polymer-protected

    Energy Technology Data Exchange (ETDEWEB)

    Nogueira, Luciana B.; Campos, Tarcisio P.R. [Universidade Federal de Minas Gerais (UFMG), Belo Horizonte, MG (Brazil). Dept. de Engenharia Nuclear. Programa de Pos-Graduacao em Ciencias e Tecnicas Nucleares

    2011-07-01

    This study aims to develop experimental dosimetry of Ho-166 bio glass seed for brachytherapy studies using GAFCHROMIC EBT2 radio chromium films. The methodology consists of placement of radio chromium films in a compressed breast phantom, along with bio glass polymer-protected seeds of [Si: Ca: Ho] and [Si: Ca: Ho: Zr]. The bio glass seeds were encapsulated with polyvinyl alcohol, before being activated and used in the study. The bio glass seeds were introduced into the breast phantom, along with radio chromium films for a period of 2 hours. After the exposure time, radio chromium films were removed from phantom and digitized for analysis in ImageDIG 2.0 program, which quantifies the intensity of RGB (Red, Green, Blue). The dose calculation was evaluated by Monte Carlo technique. Experimental and theoretical data were used to calibrate the dose distribution. The results were plotted on graphs and dose iso curves were obtained. As conclusion it is possible to perform dosimetry in Ho-166 seed brachytherapy using radio chromium films, limited to a short exposure time and small activity. (author)

  14. Experimental dosimetry of Ho-166 bioglass seed polymer-protected

    International Nuclear Information System (INIS)

    Nogueira, Luciana B.; Campos, Tarcisio P.R.

    2011-01-01

    This study aims to develop experimental dosimetry of Ho-166 bio glass seed for brachytherapy studies using GAFCHROMIC EBT2 radio chromium films. The methodology consists of placement of radio chromium films in a compressed breast phantom, along with bio glass polymer-protected seeds of [Si: Ca: Ho] and [Si: Ca: Ho: Zr]. The bio glass seeds were encapsulated with polyvinyl alcohol, before being activated and used in the study. The bio glass seeds were introduced into the breast phantom, along with radio chromium films for a period of 2 hours. After the exposure time, radio chromium films were removed from phantom and digitized for analysis in ImageDIG 2.0 program, which quantifies the intensity of RGB (Red, Green, Blue). The dose calculation was evaluated by Monte Carlo technique. Experimental and theoretical data were used to calibrate the dose distribution. The results were plotted on graphs and dose iso curves were obtained. As conclusion it is possible to perform dosimetry in Ho-166 seed brachytherapy using radio chromium films, limited to a short exposure time and small activity. (author)

  15. The effect of the radial function on I-125 seeds used for permanent prostate implantation

    International Nuclear Information System (INIS)

    Pickett, Barby; Pouliot, Jean

    2004-01-01

    The purpose of this study was to evaluate the integrity of eight commercially-available low-activity Iodine-125 ( 125 I) seeds for their radial function g(r) and its effect on the dose delivered to the adjacent critical structures when used in permanent prostate implants (PPI). Ten previously treated patients were retrospectively used in this comparison. The Amersham Health Oncura seed was used to peripherally design an isodose distribution with urethral and anterior rectal wall sparing. Plan criteria included minimum coverage of 144 Gy to the planning target volume (PTV), ≤ 70% dose to 150% of the PTV volume (V150-PTV), and the quantity of needles ≤ 70% of the size of the PTV, in cc. Upon completion of the Oncura plan, the seed type was changed and the activity was adjusted until the V100-PTV for each of the other 7 seed types matched the V100-PTV defined by the Oncura seed. Computed tomography (CT)-based postimplant dosimetry was used to determine the dose to 40% (D40) of the bulb of the penis (in Gy). Dose-volume histograms (DVH) were used to evaluate the differences to V100 (in %) and D40 (in Gy) of the anterior rectal wall and bulb of the penis, and V100 (in %) of the urethra. The data was tabulated. Radioactive 125 I sources included in this study were 125 I Source 2301 (Best); I-Plant (MedTech), IoGold (Mentor), Oncura (Amersham Health), ProstaSeed (UroCor), SelectSeed (Nucletron), SourceTech (Bard), and Symmetra (UroMed). The sizes of the PTV for the 10 patients ranged from 18.82 cc to 48.99 cc. The Oncura seed was used as the reference seed and all other seed types were normalized to it for data comparison. It was determined that the dose rate constant (xwedge) and anisotropy factor (phi) contribute to the activity needed to achieve comparable V100-PTV doses, but a strong dependence on the radial function g(r) was found to effect the doses to the critical structures studied. Values of g(r) at 4 cm were calculated and the IoGold and SourceTech seeds

  16. Space radiation measurement of plant seeds boarding on the Shijian-8 satellite

    International Nuclear Information System (INIS)

    Lv Duicai; Huang Zengxin; Zhao Yali; Wang Genliang; Jia Xianghong; Guo Huijun; Liu Luxiang; Li Chunhua; Zhang Long

    2008-01-01

    In order to identify cause of mutagenesis of plant seeds induced by space flight, especially to ascertain the interrelation between space radiation and mutagenesis, a 'photograph location' experimental setup was designed in this study. CR-39 solid-state nuclear track detectors were used to detect space heavy particles. The plant seeds and their position hit by space heavy ions were checked based on relative position between track and seeds in the setup. The low LET part of the spectrum was also measured by thermoluminescence dosemeter (TLD, LiF). The results showed that the 'photograph location' experimental method was convenient, practicable and economical. This new method also greatly saved time for microscopical analysis. On Shijian-8 satellite, the average ion flux of space heavy ions was 4.44 ions/cm 2 ·d and the average dosage of low LET space radiation to the plant seeds was 4.79 mGy. (authors)

  17. Measurement of radiation dose in dental radiology

    International Nuclear Information System (INIS)

    Helmrot, E.; Carlsson, G. A.

    2005-01-01

    Patient dose audit is an important tool for quality control and it is important to have a well-defined and easy to use method for dose measurements. In dental radiology, the most commonly used dose parameters for the setting of diagnostic reference levels (DRLs) are the entrance surface air kerma (ESAK) for intraoral examinations and dose width product (DWP) for panoramic examinations. DWP is the air kerma at the front side of the secondary collimator integrated over the collimator width and an exposure cycle. ESAK or DWP is usually measured in the absence of the patient but with the same settings of tube voltage (kV), tube current (mA) and exposure time as with the patient present. Neither of these methods is easy to use, and, in addition, DWP is not a risk related quantity. A better method of monitoring patient dose would be to use a dose area product (DAP) meter for all types of dental examinations. In this study, measurements with a DAP meter are reported for intraoral and panoramic examinations. The DWP is also measured with a pencil ionisation chamber and the product of DWP and the height H (DWP x H) of the secondary collimator (measured using film) was compared to DAP. The results show that it is feasible to measure DAP using a DAP meter for both intraoral and panoramic examinations. The DAP is therefore recommended for the setting of DRLs. (authors)

  18. Low dose stimulation in foeniculum vulgare

    International Nuclear Information System (INIS)

    Jahagirdar, H.A.; Khalatkar, A.W.; Dnyansagar, V.R.

    1974-01-01

    Genetically pure seeds with a moisture content of 12.5% were irradiated in a 60 Co γ-source at a dose rate of 1.1 KR/min, the radiation dose varying between 2 and 14 KR. Four days after irradiation the seeds were sown into the open field. Stimulation was determined on the basis of a lot of parameters e.g. height. The results indicated a significant stimulation after 10 KR as far as seed yield is concerned. (MG) [de

  19. Process Control of Pre-Sowing Seed Treatment by Pulsed Electric Field

    Directory of Open Access Journals (Sweden)

    Starodubtseva Galina Petrovna

    2018-03-01

    Full Text Available Presented paper investigates the application of a line voltage changer to an installation for pre-sowing seed treatment by pulsed electric field (PEF in order to increase the sowing quality of seeds and to suppress pathogenic microflora. The installation comprises an AC voltage regulator, a high voltage source, a voltage inverter, a working chamber for seed treatment, a control unit, and current and voltage sensors. The proposed installation differs from the existing apparatuses as it automatically provides the transformation of the pulsed electric field parameters by constant monitoring of power processes in a layer of treated seeds and feedback sending to the control unit. Seed treatment efficiency depends on the dose being determined by the parameters of electric field, namely, intensity in the seed layer, pulse duration, pulse repetition frequency, and seed treatment time. The parameters of rational treatment were determined, and the minimum treatment dose was calculated on the basis of results from the laboratory tests on the effect of pulsed electric field on sowing qualities of winter wheat seeds. It was experimentally confirmed that the proposed installation provides automatic transformation of electric field parameters depending on the changes taking place in the seed layer on the example of seeds with different moisture content maintaining the necessary treatment dose, ensuring the stability and repeatability of results.

  20. Surface coating for prevention of metallic seed migration in tissues

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Hyunseok; Park, Jong In [Program in Biomedical Radiation Sciences, Department of Transdisciplinary Studies, Graduate School of Convergence Science and Technology, Seoul National University, Seoul 151-742 (Korea, Republic of); Lee, Won Seok; Park, Min [Interdisciplinary Program in Bioengineering, Seoul National University College of Engineering, Seoul 151-742 (Korea, Republic of); Son, Kwang-Jae [Hanaro Applications Research, Korea Atomic Energy Research Institute, Daejeon 305-353 (Korea, Republic of); Bang, Young-bong [Advanced Institutes of Convergence Technology, Seoul National University, Suwon 443-270 (Korea, Republic of); Choy, Young Bin, E-mail: ybchoy@snu.ac.kr, E-mail: sye@snu.ac.kr [Interdisciplinary Program in Bioengineering, Seoul National University College of Engineering, Seoul 110-744 (Korea, Republic of); Department of Biomedical Engineering, Seoul National University College of Medicine, Seoul 110-744 (Korea, Republic of); Institute of Medical and Biological Engineering, Medical Research Center, Seoul National University, Seoul 110-744 (Korea, Republic of); Ye, Sung-Joon, E-mail: ybchoy@snu.ac.kr, E-mail: sye@snu.ac.kr [Program in Biomedical Radiation Sciences, Department of Transdisciplinary Studies, Graduate School of Convergence Science and Technology, Seoul National University, Seoul 151-742 (Korea, Republic of); Advanced Institutes of Convergence Technology, Seoul National University, Suwon 443-270 (Korea, Republic of); Department of Radiation Oncology, Seoul National University Hospital, Seoul 110-744 (Korea, Republic of)

    2015-06-15

    Purpose: In radiotherapy, metallic implants often detach from their deposited sites and migrate to other locations. This undesirable migration could cause inadequate dose coverage for permanent brachytherapy and difficulties in image-guided radiation delivery for patients. To prevent migration of implanted seeds, the authors propose a potential strategy to use a biocompatible and tissue-adhesive material called polydopamine. Methods: In this study, nonradioactive dummy seeds that have the same geometry and composition as commercial I-125 seeds were coated in polydopamine. Using scanning electron microscopy and x-ray photoelectron spectroscopy, the surface of the polydopamine-coated and noncoated seeds was characterized. The detachment stress between the two types of seeds and the tissue was measured. The efficacy of polydopamine-coated seed was investigated through in vitro migration tests by tracing the seed location after tissue implantation and shaking for given times. The cytotoxicity of the polydopamine coating was also evaluated. Results: The results of the coating characterization have shown that polydopamine was successfully coated on the surface of the seeds. In the adhesion test, the polydopamine-coated seeds had 2.1-fold greater detachment stress than noncoated seeds. From the in vitro test, it was determined that the polydopamine-coated seed migrated shorter distances than the noncoated seed. This difference was increased with a greater length of time after implantation. Conclusions: The authors suggest that polydopamine coating is an effective technique to prevent migration of implanted seeds, especially for permanent prostate brachytherapy.

  1. Measurement of the density profile of pure and seeded molecular beams by femtosecond ion imaging

    Energy Technology Data Exchange (ETDEWEB)

    Meng, Congsen [LaserLaB Amsterdam, VU University Amsterdam, de Boelelaan 1083, 1081 HV Amsterdam (Netherlands); Department of Physics, National University of Defense Technology, Changsha 410073 (China); Janssen, Maurice H. M. [LaserLaB Amsterdam, VU University Amsterdam, de Boelelaan 1083, 1081 HV Amsterdam (Netherlands)

    2015-02-15

    Here, we report on femtosecond ion imaging experiments to measure the density profile of a pulsed supersonic molecular beam. Ion images are measured for both a molecular beam and bulk gas under identical experimental conditions via femtosecond multiphoton ionization of Xe atoms. We report the density profile of the molecular beam, and the measured absolute density is compared with theoretical calculations of the centre line beam density. Subsequently, we discuss reasons accounting for the differences between measurements and calculations and propose that strong skimmer interference is the most probable cause for the differences. Furthermore, we report on experiments measuring the centre line density of seeded supersonic beams. The femtosecond ion images show that seeding the heavy Xe atom at low relative seed fractions (1%-10%) in a light carrier gas like Ne results in strong relative enhancements of up to two orders of magnitude.

  2. Investigation of pea seeds treated by 137Cs

    International Nuclear Information System (INIS)

    Lepold, J.; Soos, T.

    1979-01-01

    Two types of pea seeds were treated by 137 Cs. Radiation doses of 10 and 15 gray, resp. were applied at a dose rate of 480 gray per hour. Both the rate of sprouting and the number of plants per m 2 of the irradiated seeds exceeded the corresponding parameters of the control. The total quantity of the crop and its content of protein and water were higher, too. (L.E.)

  3. Effect of Electron Seeding on Experimentally Measured Multipactor Discharge Threshold

    Science.gov (United States)

    Noland, Jonathan; Graves, Timothy; Lemon, Colby; Looper, Mark; Farkas, Alex

    2012-10-01

    Multipactor is a vacuum phenomenon in which electrons, moving in resonance with an externally applied electric field, impact material surfaces. If the number of secondary electrons created per primary electron impact averages more than unity, the resonant interaction can lead to an electron avalanche. Multipactor is a generally undesirable phenomenon, as it can cause local heating, absorb power, or cause detuning of RF circuits. In order to increase the probability of multipactor initiation, test facilities often employ various seeding sources such as radioactive sources (Cesium 137, Strontium 90), electron guns, or photon sources. Even with these sources, the voltage for multipactor initiation is not certain as parameters such as material type, RF pulse length, and device wall thickness can all affect seed electron flux and energy in critical gap regions, and hence the measured voltage threshold. This study investigates the effects of seed electron source type (e.g., photons versus beta particles), material type, gap size, and RF pulse length variation on multipactor threshold. In addition to the experimental work, GEANT4 simulations will be used to estimate the production rate of low energy electrons (< 5 keV) by high energy electrons and photons. A comparison of the experimental fluxes to the typical energetic photon and particle fluxes experienced by spacecraft in various orbits will also be made. Initial results indicate that for a simple, parallel plate device made of aluminum, there is no threshold variation (with seed electrons versus with no seed electrons) under continuous-wave RF exposure.

  4. Barley growth and plant mineral content of plant grown from seeds irradiated by low doses of gamma irradiated and cultured on salt media

    International Nuclear Information System (INIS)

    Charbaji, T.; Arabi, M.I.; Jawhar, M.

    2000-02-01

    Seeds of two barley White Arabi (WA) Pakistani PK30163 (PK) were irradiated with three doses 0,15 and 20 Gy of gamma irradiation. Then they were cultured on (Coic-Lesaint) nutrient media containing several concentrations of NaCl (0, 10, 50, and 100 mmol). The irradiation doses did not affect the shoot growth of plants, whereas the combination between 15 Gy and 50 and 100 mmol NaCl decreased significantly the root growth. Doses of 0 and 20 Gy and 10 mmol NaCl had a positive effect on WA variety wet weight. The 20 Gy and 10 and 50 mmol NaCl significantly reduced the wet weight of PK variety. Dry weight of WA variety was decreased, when the seeds were irradiated by 15 Gy and cultured on media containing 10 and 50 mmol NaCl. WA and PK content of Ca ++ increased when weeds were irradiated by 15 Gy (WA) and 20 Gy (PK) and grown on media containing 10 mmol NaCl. The content of Mg ++ and K ++ of 2 varieties were increased, when seeds were cultured on media containing 10 mmol NaCl. Positive relationship was noticed between Na + and Cl - contents and NaCl concentrations in the media. The NaCl concentrations correlated with the irradiation, negatively effected the total N % of the WA variety, whereas in the absence of irradiation, 10 and 50 mmol NaCl had a positive effect on the total N % of PK variety. Similar effects were produced for the last variety with the dose of 15 Gy and NaCl concentrations in the media. Concentration of 100 mmol NaCl positively affect PO4 -- of unirradiated WA variety, but PO -- of all plants of PK variety was increased with 10 and 50 mmol NaCl. The content of SO4 -- of 2 varieties was increased, when the seeds were exposed to the irradiation of 15 and 20 Gy and cultured on a media containing 10 and 50 mmol NaCl. The ratio of Na/Cl, was generally different from 1 and the Cl - content was higher than Na + content, in seedlings of both barley varieties. (author)

  5. Barley growth and plant mineral content of plant grown from seeds irradiated by low doses of gamma irradiated and cultured on salt media

    Energy Technology Data Exchange (ETDEWEB)

    Charbaji, T; Arabi, M I; Jawhar, M [Atomic Energy Commission, Damascus (Syrian Arab Republic). Dept. of Agriculture

    2000-02-01

    Seeds of two barley White Arabi (WA) Pakistani PK30163 (PK) were irradiated with three doses 0,15 and 20 Gy of gamma irradiation. Then they were cultured on (Coic-Lesaint) nutrient media containing several concentrations of NaCl (0, 10, 50, and 100 mmol). The irradiation doses did not affect the shoot growth of plants, whereas the combination between 15 Gy and 50 and 100 mmol NaCl decreased significantly the root growth. Doses of 0 and 20 Gy and 10 mmol NaCl had a positive effect on WA variety wet weight. The 20 Gy and 10 and 50 mmol NaCl significantly reduced the wet weight of PK variety. Dry weight of WA variety was decreased, when the seeds were irradiated by 15 Gy and cultured on media containing 10 and 50 mmol NaCl. WA and PK content of Ca{sup ++} increased when weeds were irradiated by 15 Gy (WA) and 20 Gy (PK) and grown on media containing 10 mmol NaCl. The content of Mg{sup ++} and K{sup ++} of 2 varieties were increased, when seeds were cultured on media containing 10 mmol NaCl. Positive relationship was noticed between Na{sup +} and Cl{sup -} contents and NaCl concentrations in the media. The NaCl concentrations correlated with the irradiation, negatively effected the total N % of the WA variety, whereas in the absence of irradiation, 10 and 50 mmol NaCl had a positive effect on the total N % of PK variety. Similar effects were produced for the last variety with the dose of 15 Gy and NaCl concentrations in the media. Concentration of 100 mmol NaCl positively affect PO4{sup --} of unirradiated WA variety, but PO{sup --} of all plants of PK variety was increased with 10 and 50 mmol NaCl. The content of SO4{sup --} of 2 varieties was increased, when the seeds were exposed to the irradiation of 15 and 20 Gy and cultured on a media containing 10 and 50 mmol NaCl. The ratio of Na/Cl, was generally different from 1 and the Cl{sup -} content was higher than Na{sup +} content, in seedlings of both barley varieties. (author)

  6. Dosimetric intercomparison of permanent Ho-166 seed's implants and HDR Ir-192 brachytherapy in breast cancer.

    Science.gov (United States)

    de Campos, Tarcisio Passos Ribeiro; Nogueira, Luciana Batista; Trindade, Bruno; Cuperschmid, Ethel Mizrahy

    2016-01-01

    To provide a comparative dosimetric analysis of permanent implants of Ho(166)-seeds and temporary HDR Ir(192)-brachytherapy through computational simulation. Brachytherapy with Ir(192)-HDR or LDR based on temporary wires or permanent radioactive seed implants can be used as dose reinforcement for breast radiation therapy. Permanent breast implants have not been a practical clinical routine; although, I(125) and Pd(103)-seeds have already been reported. Biodegradable Ho(166)-ceramic-seeds have been addressed recently. Simulations of implants of nine Ho(166)-seeds and equivalent with HDR Ir(192)-brachytherapy were elaborated in MCNP5, shaped in a computational multivoxel simulator which reproduced a female thorax phantom. Spatial dose rate distributions and dose-volume histograms were generated. Protocol's analysis involving exposure time, seed's activities and dose were performed. Permanent Ho(166)-seed implants presented a maximum dose rate per unit of contained activity (MDR) of 1.1601 μGy h(-1) Bq(-1); and, a normalized MDR in standard points (8 mm, equidistant to 03-seeds - SP1, 10 mm - SP2) of 1.0% (SP1) and 0.5% (SP2), respectively. Ir(192)-brachytherapy presented MDR of 4.3945 × 10(-3) μGy h(-1) Bq(-1); and, 30% (SP1), and 20% (SP2). Therefore, seed's implant activities of 333 MBq (Ho(166)) and 259 GBq (Ir(192)) produced prescribed doses of 58 Gy (SP1; 5d) and 56 Gy (SP1, 5 fractions, 6 min), respectively. Breast Ho(166)-implants of 37-111 MBq are attractive due to the high dose rate near 6-10 mm from seeds, equivalent to Ir(192)-brachytherapy of 259 GBq (3 fractions, 6 min) providing similar dose in standard points at a week; however, with spatial dose distribution better confined. The seed positioning can be adjusted for controlling the breast tumor, in stages I and II, in flat and deep tumors, without any breast volumetric limitation.

  7. Dose measurements in pulsed radiation fields with commercially available measuring components

    International Nuclear Information System (INIS)

    Friedrich, Sabrina; Hupe, Oliver

    2016-01-01

    Dose measurements in pulsed radiation fields with dosemeters using the counting technique are known to be inappropriate. Therefore, there is a demand for a portable device able to measure the dose in pulsed radiation fields. As a detector, ionisation chambers seem to be a good alternative. In particular, using a secondary standard ionisation chamber in combination with a reliable charge-measuring system would be a good solution. The Physikalisch-Technische Bundesanstalt (PTB) uses secondary standard ionisation chambers in combination with PTB-made measuring electronics for dose measurements at its reference fields. However, for general use, this equipment is too complex. For measurements on-site, a mobile special electronic system [Hupe, O. and Ankerhold, U. Determination of ambient and personal dose equivalent for personnel and cargo security screening. Radiat. Prot. Dosim. 121(4), 429-437 (2006)] has been used successfully. Still, for general use, there is a need for a much simpler but a just as good solution. A measuring instrument with very good energy dependence for H*(10) is the secondary standard ionisation chamber HS01. An easy-to-use and commercially available electrometer for measuring the generated charges is the UNIDOS by PTW Freiburg. Depending on the expected dose values, the ionisation chamber used can be selected. In addition, measurements have been performed by using commercially available area dosemeters, e.g. the Mini SmartION 2120S by Thermo Scientific, using an ionisation chamber and the Szintomat 6134 A/H by Automess, using a scintillation detector. (authors)

  8. Toxicity of dietary Heliotropium dolosum seed to broiler chickens.

    Science.gov (United States)

    Eröksüz, Y; Eröksüz, H; Ozer, H; Canatan, H; Yaman, I; Cevik, A

    2001-12-01

    Five groups of 20 female broiler chicks were fed different levels of dehulled Heliotropium dolosum seed (w/w%; 0.0, 1.0, 3.0, 5.0 or 10.0%) from 10 to 52 d of age. In all doses the seed caused decreases in daily feed intake, weight gain, and feed efficiency, and biochemical findings, severity of pathologic changes, and mortality rate increased in a dose-dependent manner. Acute toxicity was observed in livers of chicks fed 10% seed. Other test groups had chronic changes. Livers had massive to submassive necrosis, hepatic megalocytosis, bile duct proliferation, fatty change, and periportal fibrosis. Biochemical evaluations revealed hypoalbuminemia, hypoprotienemia and increased ALP activity and billuribin. The seed of Heliotropium dolosum produced biochemical and specific pathologic changes in broiler chicks, as well as decreased food intake and feed efficiency. Higher seed levels induced more pronounced changes.

  9. Patient dose measurement and dose reduction in chest radiography

    Directory of Open Access Journals (Sweden)

    Milatović Aleksandra A.

    2014-01-01

    Full Text Available Investigations presented in this paper represent the first estimation of patient doses in chest radiography in Montenegro. In the initial stage of our study, we measured the entrance surface air kerma and kerma area product for chest radiography in five major health institutions in the country. A total of 214 patients were observed. We reported the mean value, minimum and third quartile values, as well as maximum values of surface air kerma and kerma area product of patient doses. In the second stage, the possibilities for dose reduction were investigated. Mean kerma area product values were 0.8 ± 0.5 Gycm2 for the posterior-anterior projection and 1.6 ± 0.9 Gycm2 for the lateral projection. The max/min ratio for the entrance surface air kerma was found to be 53 for the posterior-anterior projection and 88 for the lateral projection. Comparing the results obtained in Montenegro with results from other countries, we concluded that patient doses in our medical centres are significantly higher. Changes in exposure parameters and increased filtration contributed to a dose reduction of up to 36% for posterior-anterior chest examinations. The variability of the estimated dose values points to a significant space for dose reduction throughout the process of radiological practice optimisation.

  10. Radiation effects on Brassica seeds and seedlings

    Science.gov (United States)

    Deoli, Naresh; Hasenstein, Karl H.

    2016-07-01

    damage. We compared curvature in untreated with irradiated roots and measured the inhibition of curvature at 2×1013 - 8×1013 ions/cm2. Despite greater mass of imbibed seeds, the dose-response curve showed greater sensitivity of imbibed than for dry seeds. In addition, germination rate was found to be strongly dependent on ion beam current, at least for 3 MeV protons. Our data show that weak ionizing particles (low MeV protons) are suitable to study radiation effects and seedlings are a useful biological systems to study space radiation. Supported by NASA grant NNX13AN05A.

  11. Inoculation of maize with Azospirillum brasilense in the seed furrow

    Directory of Open Access Journals (Sweden)

    Tâmara Prado de Morais

    2016-06-01

    Full Text Available ABSTRACT Several studies addressing the inoculation of cereals with diazotrophic microorganisms can be found in the literature. However, in many experiments, investigators have overlooked the feasibility of applying these microorganisms to the furrow together with the seed, and the effect of bacterial concentration on phytostimulation. The aim of this work was to evaluate the effect of doses of an inoculant based on Azospirillum brasilense, applied to the seed furrow when planting maize, combined with different doses of nitrogen fertiliser. The experiment was carried out in the field, in soil of the cerrado region of Brazil. An experimental design of randomised blocks in bands was adopted, comprising nitrogen (40, 100, 200 and 300 kg ha-1 and doses of an A. brasilense-based liquid inoculant applied to the seed furrow (0, 100, 200, 300 and 400 mL ha-1. The dose of 200 mL ha-1Azospirillum was noteworthy for grain production. This is the first report of the effective application of Azospirillum in the seed furrow when planting maize in the cerrado region of Brazil.

  12. Measuring pacemaker dose: A clinical perspective

    Energy Technology Data Exchange (ETDEWEB)

    Studenski, Matthew T., E-mail: matthew.studenski@jeffersonhospital.org [Department of Radiation Oncology at the Jefferson Medical College and Kimmel Cancer Center, Thomas Jefferson University, Philadelphia, PA (United States); Xiao Ying; Harrison, Amy S. [Department of Radiation Oncology at the Jefferson Medical College and Kimmel Cancer Center, Thomas Jefferson University, Philadelphia, PA (United States)

    2012-07-01

    Recently in our clinic, we have seen an increased number of patients presenting with pacemakers and defibrillators. Precautions are taken to develop a treatment plan that minimizes the dose to the pacemaker because of the adverse effects of radiation on the electronics. Here we analyze different dosimeters to determine which is the most accurate in measuring pacemaker or defibrillator dose while at the same time not requiring a significant investment in time to maintain an efficient workflow in the clinic. The dosimeters analyzed here were ion chambers, diodes, metal-oxide-semiconductor field effect transistor (MOSFETs), and optically stimulated luminescence (OSL) dosimeters. A simple phantom was used to quantify the angular and energy dependence of each dosimeter. Next, 8 patients plans were delivered to a Rando phantom with all the dosimeters located where the pacemaker would be, and the measurements were compared with the predicted dose. A cone beam computed tomography (CBCT) image was obtained to determine the dosimeter response in the kilovoltage energy range. In terms of the angular and energy dependence of the dosimeters, the ion chamber and diode were the most stable. For the clinical cases, all the dosimeters match relatively well with the predicted dose, although the ideal dosimeter to use is case dependent. The dosimeters, especially the MOSFETS, tend to be less accurate for the plans, with many lateral beams. Because of their efficiency, we recommend using a MOSFET or a diode to measure the dose. If a discrepancy is observed between the measured and expected dose (especially when the pacemaker to field edge is <10 cm), we recommend analyzing the treatment plan to see whether there are many lateral beams. Follow-up with another dosimeter rather than repeating multiple times with the same type of dosimeter. All dosimeters should be placed after the CBCT has been acquired.

  13. Radiobiologically based treatment plan evaluation for prostate seed implants

    Directory of Open Access Journals (Sweden)

    Sotirios Stathakis

    2011-07-01

    Full Text Available Purpose: Accurate prostate low dose-rate brachytherapy treatment plan evaluation is important for future care decisions. Presently, an evaluation is based on dosimetric quantifiers for the tumor and organs at risk. However, these do not account for effects of varying dose-rate, tumor repopulation and other biological effects. In this work, incorporation of the biological response is used to obtain more clinically relevant treatment plan evaluation.Material and methods: Eleven patients were evaluated. Each patient received a 145 Gy implant. Iodine-125 seeds were used and the treatment plans were created on the Prowess system. Based on CT images the post-implant plan was created. In the post-plan, the tumor, urethra, bladder and rectum were contoured. The biologically effective dose was used to determine the tumor control probability and the normal tissue complication probabilities for the urethra, bladder, rectum and surrounding tissue. Results: The average tumor control probability and complication probabilities for the urethra, bladder, rectum and surrounding tissue were 99%, 29%, 0%, 12% and 6%, respectively. These measures provide a simpler means for evaluation and since they include radiobiological factors, they provide more reliable estimation of the treatment outcome. Conclusions: The goal of this work was to create more clinically relevant prostate seed-implant evaluation by incorporating radiobiological measures. This resulted in a simpler descriptor of treatment plan quality and was consistent with patient outcomes.

  14. Out-of-field dose measurements in radiotherapy

    Energy Technology Data Exchange (ETDEWEB)

    Kaderka, Robert

    2011-07-13

    This thesis describes the results from measurements of the out-of-field dose in radiotherapy. The dose outside the treatment volume has been determined in a water phantom and an anthropomorphic phantom. Measurements were performed with linac photons, passively delivered protons, scanned protons, passively delivered carbon ions as well as scanned carbon ions. It was found that the use of charged particles for radiotherapy reduces the out-of-field dose by up to three orders of magnitude compared to conventional radiotherapy with photons.

  15. Skin Dose Equivalent Measurement from Neutron-Deficient Isotopes

    International Nuclear Information System (INIS)

    Hsu, Hsiao-Hua; Costigan, Steve A.; Romero, Leonard L.; Whicker, Jeffrey J.

    1997-12-01

    Neutron-deficient-isotopes decay via positron emission and/or electron capture often followed by x-ray, gamma-ray, and 0.511 MeV photons from positron annihilation. For cases of significant area and/or personnel contamination with these isotopes, determination of skin dose equivalent (SDE) is required by 10CFR835. For assessment of SDE, we evaluated the MICROSPEC-2(TM) system manufactured by Bubble Technology Industries of Canada which uses three different probes for dose measurement. We used two probes: (1) the X-probe which measures lower energy (4 - 120 keV) photon energy distributions and determines deep dose equivalent, SDE and dose equivalent to eyes, and (2) the B-probe which measures electron (positron) energy distributions, and determines skin dose equivalent. Also, the measured photon and beta spectra can be used to identify radioactive isotopes in the contaminated area. Measurements with several neutron-deficient sources showed that this system provided reasonably accurate SDE rate measurements when compared with calculated benchmark SDE rates with an average percent difference of 40%. Variations were expected because of differences between the assumed geometries used by MlCROSPEC-2 and the calculations when compared to the measurement conditions

  16. Effect of gamma ray irradiation on seed germination of Ardisia crenata

    International Nuclear Information System (INIS)

    Huang Donghua; Xu Hong; Huang Yanping; Song Xiaomin

    2011-01-01

    The seeds of Ardisia crenata were used as experimental material and treated with gamma ray under the irradiative doses ranging from 50 to 500 Gy. The results showed that the seed germination rates were not affected under the irradiative dose of 150 Gy and below. The germination potentiality turned to reduce while the irradiative dose was higher than 250 Gy. And in the range of 300 to 500 Gy the germination rates were decreased with the increase of the irradiative dose. (authors)

  17. Dose rate constants for 125I, 103Pd, 192Ir and 169Yb brachytherapy sources: an EGS4 Monte Carlo study

    International Nuclear Information System (INIS)

    Mainegra, Ernesto; Capote, Roberto; Lopez, Ernesto

    1998-01-01

    An exhaustive revision of dosimetry data for 192 Ir, 125 I, 103 Pd and 169 Yb brachytherapy sources has been performed by means of the EGS4 simulation system. The DLC-136/PHOTX cross section library, water molecular form factors, bound Compton scattering and Doppler broadening of the Compton-scattered photon energy were considered in the calculations. The absorbed dose rate per unit contained activity in a medium at 1 cm in water and air-kerma strength per unit contained activity for each seed model were calculated, allowing the dose rate constant (DRC) Λ to be estimated. The influence of the calibration procedure on source strength for low-energy brachytherapy seeds is discussed. Conversion factors for 125 I and 103 Pd seeds to obtain the dose rate in liquid water from the dose rate measured in a solid water phantom with a detector calibrated for dose to water were calculated. A theoretical estimate of the DRC for a 103 Pd model 200 seed equal to 0.669±0.002 cGy h -1 U -1 is obtained. Comparison of obtained DRCs with measured and calculated published results shows agreement within 1.5% for 192 Ir, 169 Yb and 125 I sources. (author)

  18. SU-F-J-157: Effect of Contouring Uncertainty in Post Implant Dosimetry of Low-Dose-Rate Prostate Permanent Seed Brachytherapy

    Energy Technology Data Exchange (ETDEWEB)

    Mashouf, S; Merino, T; Ravi, A; Morton, G; Song, W [Sunnybrook Health Sciences Center, Odette Cancer Centre, Toronto, ON (Canada); University of Toronto, Dept. of Radiation Oncology, Toronto, ON (Canada); Safigholi, H; Soliman, A [Sunnybrook Research Institute, Toronto, ON (Canada)

    2016-06-15

    Purpose: There is strong evidence relating post-implant dosimetry for low-dose-rate (LDR) prostate seed brachytherapy to local control rates. The delineation of the prostate on CT images, however, represents a challenge due to the lack of soft tissue contrast in order to identify the prostate borders. This study aims at quantifying the sensitivity of clinically relevant dosimetric parameters to uncertainty in the contouring of prostate. Methods: CT images, post-op plans and contours of a cohort of patients (n=43) (low risk=55.8%, intermediate risk=39.5%, high risk=4.7%), who had received prostate seed brachytherapy, were imported into MIM Symphony treatment planning system. The prostate contours in post-implant CT images were expanded/contracted uniformly for margins of ±1.00 mm, ±2.00 mm, ±3.00 mm, ±4.00 mm and ±5.00 mm. The values for V100 and D90 were extracted from Dose Volume Histograms for each contour and compared. Results: Significant changes were observed in the values of D90 and V100 as well as the number of suboptimal plans for expansion or contraction margins of only few millimeters. Evaluation of coverage based on D90 was found to be less sensitive to expansion errors compared to V100. D90 led to a lower number of implants incorrectly identified with insufficient coverage for expanded contours which increases the accuracy of post-implant QA using CT images compared to V100. Conclusion: In order to establish a successful post implant QA for LDR prostate seed brachytherapy, it is necessary to identify the low and high thresholds of important dose metrics of the target volume such as D90 and V100. Since these parameters are sensitive to target volume definition, accurate identification of prostate borders would help to improve accuracy and predictive value of the post-implant QA process. In this respect, use of imaging modalities such as MRI where prostate is well delineated should prove useful.

  19. SU-F-J-157: Effect of Contouring Uncertainty in Post Implant Dosimetry of Low-Dose-Rate Prostate Permanent Seed Brachytherapy

    International Nuclear Information System (INIS)

    Mashouf, S; Merino, T; Ravi, A; Morton, G; Song, W; Safigholi, H; Soliman, A

    2016-01-01

    Purpose: There is strong evidence relating post-implant dosimetry for low-dose-rate (LDR) prostate seed brachytherapy to local control rates. The delineation of the prostate on CT images, however, represents a challenge due to the lack of soft tissue contrast in order to identify the prostate borders. This study aims at quantifying the sensitivity of clinically relevant dosimetric parameters to uncertainty in the contouring of prostate. Methods: CT images, post-op plans and contours of a cohort of patients (n=43) (low risk=55.8%, intermediate risk=39.5%, high risk=4.7%), who had received prostate seed brachytherapy, were imported into MIM Symphony treatment planning system. The prostate contours in post-implant CT images were expanded/contracted uniformly for margins of ±1.00 mm, ±2.00 mm, ±3.00 mm, ±4.00 mm and ±5.00 mm. The values for V100 and D90 were extracted from Dose Volume Histograms for each contour and compared. Results: Significant changes were observed in the values of D90 and V100 as well as the number of suboptimal plans for expansion or contraction margins of only few millimeters. Evaluation of coverage based on D90 was found to be less sensitive to expansion errors compared to V100. D90 led to a lower number of implants incorrectly identified with insufficient coverage for expanded contours which increases the accuracy of post-implant QA using CT images compared to V100. Conclusion: In order to establish a successful post implant QA for LDR prostate seed brachytherapy, it is necessary to identify the low and high thresholds of important dose metrics of the target volume such as D90 and V100. Since these parameters are sensitive to target volume definition, accurate identification of prostate borders would help to improve accuracy and predictive value of the post-implant QA process. In this respect, use of imaging modalities such as MRI where prostate is well delineated should prove useful.

  20. Measurement of spatial dose distribution for evaluation operator dose during nero-interventional procedures

    International Nuclear Information System (INIS)

    Han, Su Chul; Hong, Dong Hee

    2016-01-01

    The spatial dose distribution was measured with ionization chamber as preliminary study to evaluate operator dose and to study dose reduction during neuro-interventional procedures. The zone of operators was divided into four area (45, 135, 225, and 315 degree).We supposed that operator exist on the four area and indicated location of critical organs(eyes, breast, gonad). The spatial doses were measured depending on distance( 80, 100, 120, and 140 cm) and location of critical organs. The spatial doses of area of 225 degree were 114.5 mR/h (eyes location), 143.1 mR/h (breast location) and 147 mR/h (gonad location) in 80 cm. When changed location of x-ray generator, spatial dose increased in 18.1±10.5%, averagely. We certified spatial dose in the operator locations, Using the results of this study, It is feasible to protect operator from radiation in neuro-interventional procedures

  1. Measurement of spatial dose distribution for evaluation operator dose during nero-interventional procedures

    Energy Technology Data Exchange (ETDEWEB)

    Han, Su Chul [Division of Medical Radiation Equipment, Korea Institute of Radiological and Medical Sciences, Seoul (Korea, Republic of); Hong, Dong Hee [Dept. of Radiology Science, Far East University, Eumseong (Korea, Republic of)

    2016-09-15

    The spatial dose distribution was measured with ionization chamber as preliminary study to evaluate operator dose and to study dose reduction during neuro-interventional procedures. The zone of operators was divided into four area (45, 135, 225, and 315 degree).We supposed that operator exist on the four area and indicated location of critical organs(eyes, breast, gonad). The spatial doses were measured depending on distance( 80, 100, 120, and 140 cm) and location of critical organs. The spatial doses of area of 225 degree were 114.5 mR/h (eyes location), 143.1 mR/h (breast location) and 147 mR/h (gonad location) in 80 cm. When changed location of x-ray generator, spatial dose increased in 18.1±10.5%, averagely. We certified spatial dose in the operator locations, Using the results of this study, It is feasible to protect operator from radiation in neuro-interventional procedures.

  2. Technique and effects of pre-sowing laser biostimulation of cucumber seeds

    International Nuclear Information System (INIS)

    Gładyszewska, B.; Koper, R.; Kornarzyński, K.

    1998-01-01

    Laser treatment of seeds before sowing at selected irradiation doses was described. Particular attention was paid to determining energy doses for biostimulation. Results obtained at experimental irradiation of short green-house cucumber seeds, Pasandra and Picobello cultivars, were presented. Considerable increase in yields was observed as a result of applied method

  3. Dose heterogeneity correction for low-energy brachytherapy sources using dual-energy CT images

    Science.gov (United States)

    Mashouf, S.; Lechtman, E.; Lai, P.; Keller, B. M.; Karotki, A.; Beachey, D. J.; Pignol, J. P.

    2014-09-01

    Permanent seed implant brachytherapy is currently used for adjuvant radiotherapy of early stage prostate and breast cancer patients. The current standard for calculation of dose around brachytherapy sources is based on the AAPM TG-43 formalism, which generates the dose in a homogeneous water medium. Recently, AAPM TG-186 emphasized the importance of accounting for tissue heterogeneities. We have previously reported on a methodology where the absorbed dose in tissue can be obtained by multiplying the dose, calculated by the TG-43 formalism, by an inhomogeneity correction factor (ICF). In this work we make use of dual energy CT (DECT) images to extract ICF parameters. The advantage of DECT over conventional CT is that it eliminates the need for tissue segmentation as well as assignment of population based atomic compositions. DECT images of a heterogeneous phantom were acquired and the dose was calculated using both TG-43 and TG-43 × \\text{ICF} formalisms. The results were compared to experimental measurements using Gafchromic films in the mid-plane of the phantom. For a seed implant configuration of 8 seeds spaced 1.5 cm apart in a cubic structure, the gamma passing score for 2%/2 mm criteria improved from 40.8% to 90.5% when ICF was applied to TG-43 dose distributions.

  4. Hot seeding using large Y-123 seeds

    International Nuclear Information System (INIS)

    Scruggs, S J; Putman, P T; Zhou, Y X; Fang, H; Salama, K

    2006-01-01

    There are several motivations for increasing the diameter of melt textured single domain discs. The maximum magnetic field produced by a trapped field magnet is proportional to the radius of the sample. Furthermore, the availability of trapped field magnets with large diameter could enable their use in applications that have traditionally been considered to require wound electromagnets, such as beam bending magnets for particle accelerators and electric propulsion. We have investigated the possibility of using large area epitaxial growth instead of the conventional point nucleation growth mechanism. This process involves the use of large Y123 seeds for the purpose of increasing the maximum achievable Y123 single domain size. The hot seeding technique using large Y-123 seeds was employed to seed Y-123 samples. Trapped field measurements indicate that single domain samples were indeed grown by this technique. Microstructural evaluation indicates that growth can be characterized by a rapid nucleation followed by the usual peritectic grain growth which occurs when large seeds are used. Critical temperature measurements show that no local T c suppression occurs in the vicinity of the seed. This work supports the suggestion of using an iterative method for increasing the size of Y-123 single domains that can be grown

  5. Thermoluminescent dosimeters for low dose X-ray measurements

    International Nuclear Information System (INIS)

    Del Sol Fernández, S.; García-Salcedo, R.; Sánchez-Guzmán, D.; Ramírez-Rodríguez, G.; Gaona, E.; León-Alfaro, M.A. de; Rivera-Montalvo, T.

    2016-01-01

    The response of TLD-100, CaSO_4:Dy and LiF:Mg,Cu,P for a range of X-ray low dose was measured. For calibration, the TLDs were arranged at the center of the X-ray field. The dose output of the X-ray machine was determined using an ACCU-Gold. All dosimeters were exposed at the available air kerma values of 14.69 mGy within a field 10×10 cm"2 at 80 cm of SSD. Results of LiF:Mg,Cu,P X-ray irradiated showed 4.8 times higher sensitivity than TLD-100. Meanwhile, TL response of CaSO_4:Dy exposed at the same dose was 5.6 time higher than TLD-100. Experimental results show for low dose X-ray measurements a better linearity for LiF:Mg,Cu,P compared with that of TLD-100. CaSO_4:Dy showed a linearity from 0.1 to 60 mGy - Highlights: • Low dose X-ray doses for personal dosimetry were measured. • Radiation dose (µGy ) for environmental dosimetry were determined. • Scattering radiation dose were measured by TLDs. • Linearity of pair TLD system was successful in the range of microgray. • Pair TLDs composed by CaSO_4:Dy and by LiF:Mg,Cu,P. is suggested for clinical dosimetry.

  6. The effect of 60Co γ-rays irradiation on seeds and branches of Euonymus fortunei

    International Nuclear Information System (INIS)

    Ao Yan; Inner Mongolia Agriculture Univ., Huhhot; Zhang Guosheng; Lu Renqiang; Pan Qinghua

    2006-01-01

    Seeds and plant branches of Euonymus fortunei were irradiated with 60 Co γ-ray. The results showed that after irradiation, seed germination rate, emergence rate and surviving rate were restrained, and it was negatively correlated with irradiation dose increasing significantly. The first euphylis period was delayed compared with control. Seedling height decreased with the increase of irradiation dose. Semi-lethal dose of Euonymus fortunei seeds was 128.56 Gy. Branch irradiation could cause significantly number and length reduced, and it is correlated with irradiation dose increasing. The semi-lethal dose for Euonymus fortunei branches was 95.54 Gy. (authors)

  7. Poster - 08: Preliminary Investigation into Collapsed-Cone based Dose Calculations for COMS Eye Plaques

    International Nuclear Information System (INIS)

    Morrison, Hali; Menon, Geetha; Sloboda, Ron

    2016-01-01

    Purpose: To investigate the accuracy of model-based dose calculations using a collapsed-cone algorithm for COMS eye plaques loaded with I-125 seeds. Methods: The Nucletron SelectSeed 130.002 I-125 seed and the 12 mm COMS eye plaque were incorporated into a research version of the Oncentra® Brachy v4.5 treatment planning system which uses the Advanced Collapsed-cone Engine (ACE) algorithm. Comparisons of TG-43 and high-accuracy ACE doses were performed for a single seed in a 30×30×30 cm 3 water box, as well as with one seed in the central slot of the 12 mm COMS eye plaque. The doses along the plaque central axis (CAX) were used to calculate the carrier correction factor, T(r), and were compared to tabulated and MCNP6 simulated doses for both the SelectSeed and IsoAid IAI-125A seeds. Results: The ACE calculated dose for the single seed in water was on average within 0.62 ± 2.2% of the TG-43 dose, with the largest differences occurring near the end-welds. The ratio of ACE to TG-43 calculated doses along the CAX (T(r)) of the 12 mm COMS plaque for the SelectSeed was on average within 3.0% of previously tabulated data, and within 2.9% of the MCNP6 simulated values. The IsoAid and SelectSeed T(r) values agreed within 0.3%. Conclusions: Initial comparisons show good agreement between ACE and MC doses for a single seed in a 12 mm COMS eye plaque; more complicated scenarios are being investigated to determine the accuracy of this calculation method.

  8. Poster - 08: Preliminary Investigation into Collapsed-Cone based Dose Calculations for COMS Eye Plaques

    Energy Technology Data Exchange (ETDEWEB)

    Morrison, Hali; Menon, Geetha; Sloboda, Ron [Cross Cancer Institute, Edmonton, AB, and University of Alberta, Edmonton, AB, Cross Cancer Institute, Edmonton, AB, and University of Alberta, Edmonton, AB, Cross Cancer Institute, Edmonton, AB, and University of Alberta, Edmonton, AB (Canada)

    2016-08-15

    Purpose: To investigate the accuracy of model-based dose calculations using a collapsed-cone algorithm for COMS eye plaques loaded with I-125 seeds. Methods: The Nucletron SelectSeed 130.002 I-125 seed and the 12 mm COMS eye plaque were incorporated into a research version of the Oncentra® Brachy v4.5 treatment planning system which uses the Advanced Collapsed-cone Engine (ACE) algorithm. Comparisons of TG-43 and high-accuracy ACE doses were performed for a single seed in a 30×30×30 cm{sup 3} water box, as well as with one seed in the central slot of the 12 mm COMS eye plaque. The doses along the plaque central axis (CAX) were used to calculate the carrier correction factor, T(r), and were compared to tabulated and MCNP6 simulated doses for both the SelectSeed and IsoAid IAI-125A seeds. Results: The ACE calculated dose for the single seed in water was on average within 0.62 ± 2.2% of the TG-43 dose, with the largest differences occurring near the end-welds. The ratio of ACE to TG-43 calculated doses along the CAX (T(r)) of the 12 mm COMS plaque for the SelectSeed was on average within 3.0% of previously tabulated data, and within 2.9% of the MCNP6 simulated values. The IsoAid and SelectSeed T(r) values agreed within 0.3%. Conclusions: Initial comparisons show good agreement between ACE and MC doses for a single seed in a 12 mm COMS eye plaque; more complicated scenarios are being investigated to determine the accuracy of this calculation method.

  9. measurement of high dose radiation using yellow perspex dosimeter

    International Nuclear Information System (INIS)

    Thamrin, M Thoyib; Sofyan, Hasnel

    1996-01-01

    Measurement of high dose radiation using yellow perspex dosemeter has been carried out. Dose range used was between 0.1 to 3.0 kGy. Measurement of dose rate against Fricke dosemeter as a standard dose meter From the irradiation of Fricke dosemeter with time variation of 3,6,9,12,15 and 18 minute, it was obtained average dose rate of 955.57 Gy/hour, linear equation of dose was Y= 2.333+15.776 X with its correlation factor r = 0.9999. Measurement result using yellow perspex show that correlation between net optical density and radiation dose was not linear with its equation was ODc exp. [Bo + In(dose).Bi] Value of Bo = -0.215 and Bi=0.5020. From the experiment it was suggested that routine dosimeter (yellow perspex) should be calibrated formerly against standard dosemeters

  10. In vivo measurement of urethral dose profiles

    International Nuclear Information System (INIS)

    Toye, W.C.; Royal Melbourne Institute of Technology,; Duchesne, G.M.; Das, K.R.; Cee, A.; Mameghan, H.; Johnston, P.N.

    2001-01-01

    Full text: Quality assurance becomes a critical requirement when radiographs are routinely used in planning of treatments. In HDR prostate brachytherapy, the surrounding organs at risk of complications are the bladder and the rectum. However, of particular concern is the urethra that runs centrally through the prostate gland, as an unavoidably high dose can occur in the central region in order to achieve a minimum peripheral dose to a small target volume. Although high urethral doses have previously been related to increased urinary symptoms, some recent studies have not found such a correlation. The aim of this study was firstly, to identify dosimetric indicators of urethral morbidity following HDR prostate brachytherapy (4F x of 5.0 Gy), and secondly, to test the validity of calculated dose values. The in vivo measurements utilised a TLD (LiF:Mg,Ti) train formed by loading eight TLD rods alternating with 1,0 cm brass spacers into a fine plastic flexible tube. The length and diameter of plastic tubing was approximately 45cm and 0.15cm respectively, while the train length was 11.8 cm from the tip of the tube. The TLD train was placed into the central lumen of an 18 F three-way urethral catheter prior to its insertion. Significant urinary morbidity was defined prospectively as a score of a total of 3 or more points for severity from 5 symptoms categories. The five symptoms evaluated were hesitancy, frequency/nocturia, dysuria, haematuria and incontinence. The introduction of in vivo measurements to enhance the existing dosimetric analysis may be required to fully test the quantitative relationships (e.g. dose-volume ratios). Placement of TLDs within the urethra results in measurements whose accuracy is unaffected by internal organ motion as the hollow urethra must move with the prostate. The dose recorded by the TLDs is determined independently of the predictive algorithm used by the treatment planning system, and prostate location errors (e.g. due to image

  11. Passive Rn dose meters - measuring methods appropriate for large measurement series

    International Nuclear Information System (INIS)

    Urban, M.; Kiefer, H.

    1985-01-01

    Passive integrating measuring methods can be classified in several groups by their functioning principle, e.g. spray chambers or open chambers with nuclear trace detectors or TL detectors, open detectors, activated carbon dose meters with or without TL detectors. According to the functioning principle, only radon or radon and fission products can be detected. The lecture gives a survey of the present state of development of passive Rn dose meters. By the example of the Ra dose meter developed at Karlsruhe which was used in inquiry measurements carried out in Germany, Switzerland, the Netherlands, Belgium and Austria, etching technology, estimation of measuring uncertainties, reproducibility and fading behaviour shall be discussed. (orig./HP) [de

  12. 60Co γ-ray irradiation effect on germination and seedling growth of dry Buchloe dactyloides seeds

    International Nuclear Information System (INIS)

    Wang Wen'en; Zhang Junwei; Bao Manzhu

    2005-01-01

    The dry seeds of Buchloe dactyloides were irradiated by γ-ray at dose of 25-300 Gy. Seed germination and seedling characters were surveyed in laboratory and field. The results indicated that radiation could promote seed germination, and the optimum dose was 100 Gy. The dose of 150 Gy was the up limit to germination rate, root length and seedling height in field. When the radiation dose was bellow 100 Gy, the fresh weight of stems, leaves and roots of seedlings were increased. From this study, the recommended radiation does for Buchloe dactyloides dry seeds treatment was between 100-150 Gy for the purpose of promoting germination. (authors)

  13. Measurement of the equivalent dose in quartz using a regenerative-dose single-aliquot protocol

    International Nuclear Information System (INIS)

    Murray, A.S.; Roberts, R.G.

    1998-01-01

    The principles behind a regenerative-dose single-aliquot protocol are outlined. It is shown for three laboratory-bleached Australian sedimentary quartz samples that the relative change in sensitivity of the optically stimulated luminescence (OSL) during a repeated measurement cycle (consisting of a dose followed by a 10 s preheat at a given temperature and then a 100 s exposure to blue/green light at 125 deg. C) is very similar to that of the 110 deg. C thermoluminescence (TL) peak measured during the preheat cycle. The absolute change in the TL sensitivity with preheat temperature is different for samples containing a natural or a regenerative dose. Furthermore, the absolute change in sensitivity in both the OSL and TL signals is non-linear with regeneration cycle, but the relative change in the OSL signal compared to the following 110 deg. C TL measurement is well approximated by a straight line. Both signals are thought to use the same luminescence centres, and so some common behaviour is not unexpected. A new regenerative-dose protocol is presented which makes use of this linear relationship to correct for sensitivity changes with regeneration cycle, and requires only one aliquot for the estimation of the equivalent dose (D e ). The protocol has been applied to quartz from nine Australian sites. To illustrate the value of the regenerative-dose single-aliquot approach, the apparent values of D e for 13 samples, containing doses of between 0.01 and 100 Gy, have been measured at various preheat temperatures of between 160 and 300 deg. C, using a single aliquot for each D e measurement. Excellent agreement is found between these single-aliquot estimates of D e and those obtained from additive-dose multiple-aliquot and single-aliquot protocols, over the entire dose range

  14. Determination of Dosimetric Parameters of the Second Model of Pd-103 Seed Manufactured at Agricultural, Medical and Industrial Research School

    Directory of Open Access Journals (Sweden)

    Gholamreza Raisali

    2008-06-01

    Full Text Available Introduction: The use of low energy isotopes such as  103 Pd in brachytherapy for the treatment of cancers  such as prostate, eye, head, neck, breast and cervix is increasing. In this regard, different models of Pd- 103  seeds  have  been  designed  and  manufactured  at  the  Agricultural,  Medical  and  Industrial  Research  School (AMIRS of Atomic Energy Organization of Iran. In this research, the dosimetric parameters of  the second model of Pd-103 seed manufactured at AMIRS have been calculated and measured.   Materials and Methods: The dosimetric parameters of the second Pd-103 seed manufactured at AMIRS  were determined according to TG-43U1 protocol using Monte Carlo calculations (MCNP4C computer  code  and  measurements  performed  using  TLD-GR200A  dosimeters  in  a  Perspex  phantom.  The  parameters  include  dose  rate  constant,  geometry  function,  radial  dose  function,  anisotropy  function,  anisotropy factor and anisotropy constant.  Results:  It  was  found  that  by  using  MCNP4C  code  the  calculated  dose  rate  constant  in  water  and  Perspex  was  0.706±0.001   and  0.501±0.001  cGyh -1 U -1 , respectively.  Using  the  calculated  geometry  function,  the  radial  dose  function  and  the  anisotropy  function  were  determined  by  experimental  and  theoretical methods in water and Perspex phantom. Also, the calculated value of anisotropy constant in  water was equal to 0.88.  Discussion and Conclusion: A discrepancy of less than 10% between the calculated and the measured  values indicates a reasonable agreement between the simulation and the measurement method. Also, the  dosimetric parameters of this seed have been compared to the dosimetric parameters of the first Pd-103  seed  manufactured  at  AMIRS  and  some  other  seeds.  The  obtained  results  indicate  that  the  seeds  manufactured at AMIRS

  15. Dose measurement method suitable for management of food irradiation

    International Nuclear Information System (INIS)

    Tanaka, Ryuichi

    1990-01-01

    The report describes major features of dose measurement performed for the management of food irradiation processes, and dose measuring methods suitable for this purpose, and outlines some activities for establishing international standards for dose measurement. Traceability studies made recently are also reviewed. Compared with the sterilization of medical materials, food irradiation is different in some major points from a viewpoint of dose measurement: foods can undergo significant changes in bulk density, depending on its properties, during irradiation, and the variation in the uniformity of bulk density can be large within an irradiation unit and among different units. An accurate dosimeter and well-established traceability are essential for food irradiation control, and basically a dosimeter should be high in reproducibility and stable in dose response, and should be easy to readjust for eliminating systematic errors. A new type of dosimeter was developed recently, in which ESR is used to measure the free radicals generated by radiations in crystals of alanine, an amino acid. Standardization of large dose measurement procedures has been carried out by committee E10 set up under ASTM. (N.K.)

  16. Dosimetry study of three-dimensional print template-guided precision 125I seed implantation

    Directory of Open Access Journals (Sweden)

    Zhang Hongtao

    2016-01-01

    Conclusions: The postplan and preplan dose parameters of 3D print template-guided seed implantation were nearly consistent. The dose parameters of template group superior to the traditional group. The seeds can be implanted accurately with 3D print template.

  17. VARIATION IN RHIZOBIUM GROWTH DUE TO SEED AND ROOT EXUDATES RELEASED FROM GAMMA IRRADIATED GLYCINE MAX SEEDS

    International Nuclear Information System (INIS)

    KAMEL, H.A.; ASKER, M.M.S

    2008-01-01

    In this study, seeds of Glycine max Giza 122 were irradiated with gamma rays from 60 Co source at various doses (10 to 200 Gy), sterilized and soaked into an aerated solution of CaSO 4 (1 mmol and pH 6.5). The capacities of the released seed exudates (SEs) and root exudates (REs) to promote Rhizobium leguminosarum growth were investigated as well as biochemical analysis of the exudates was carried out. SE of both control and gamma irradiated seeds resulted in a higher Rhizobium population and polysaccharide production than RE. Relative to control, the highly effective doses in Rhizobium growth and polysaccharide production were 25 and 200 Gy; the former was a promoter while the later was an inhibitor. HPLC analysis of soluble carbohydrates revealed the presence of glucose (Glu), rhamnose (Rha) and fructose (Fru) in the SE and RE. Protein content in SE was lower than that in RE; the highest values were due to 10 Gy and 25 Gy in SE and RE, respectively. Free amino acids content in SE was increased up to 25 Gy then decreased while RE was increased by increasing gamma doses from 10 to 200 Gy

  18. COMP report: CPQR technical quality control guidelines for low-dose-rate permanent seed brachytherapy.

    Science.gov (United States)

    Beaulieu, Luc; Radford, Dee-Ann; Eduardo Villarreal-Barajas, J

    2018-03-14

    The Canadian Organization of Medical Physicists (COMP), in close partnership with the Canadian Partnership for Quality Radiotherapy (CPQR) has developed a series of Technical Quality Control (TQC) guidelines for radiation treatment equipment. These guidelines outline the performance objectives that equipment should meet in order to ensure an acceptable level of radiation treatment quality. The TQC guidelines have been rigorously reviewed and field tested in a variety of Canadian radiation treatment facilities. The development process enables rapid review and update to keep the guidelines current with changes in technology. This article contains detailed performance objectives and safety criteria for low-dose-rate (LDR) permanent seed brachytherapy. © 2018 The Authors. Journal of Applied Clinical Medical Physics published by Wiley Periodicals, Inc. on behalf of American Association of Physicists in Medicine.

  19. Physical requirements for measurement of radiation dose and their relationship to personnel dose meter design and use

    International Nuclear Information System (INIS)

    Chabot, G.E. Jr.; Jimenez, M.A.; Skrable, K.W.

    1978-01-01

    This paper stems from the concerns of the authors with both the design of current personnel dose meters and the interpretation of dose information from them in light of the actual physical requirements to measure dose. These concerns have been reinforced and extended following a comparative study of the responses of particular TLD and film systems and as the result of a recent national survey on personnel dosimetry conducted by the authors. Among the major points discussed are the systems available for penetrating and shallow dose assessment, dose meter calibration, the measurement and interpretation of skin dose, and the deficiencies of neutron albedo dose meters for routine personnel use. Calibration considerations address the questions of whether or not a phantom should be used and the difference in interpretation of responses with and without a phantom; the relationship between calculated and measured doses; and electronic equilibrium considerations in the measurement of photon doses. Matters of importance in relation to skin dose measurement include techniques in use to interpret skin dose from dose meter response; the appropriateness of evaluation of the surface dose to the live skin layer versus the average dose to the live skin layer and the limitations and requirements on dose meter design with respect to the dose being evaluated; and the significance of dose meter response in relationship to currently used beta calibration standards. Regarding the use of TLD albedo type neutron dose meters currently available, considerations are extended to the strong energy spectral dependence of the dose meter response and the possibility of making significant over or underestimations of neutron dose equivalent, depending on the calibration techniques used and the spectral quality encountered. (author)

  20. Contribution to the study of the effect of a low dose of gamma irradiation on seeds and tubers before planting

    International Nuclear Information System (INIS)

    Silvy, A.

    1968-01-01

    From 1962 to 1965, 25 tests have been made with carrots (1 variety), radish (3 varieties), spinach (2 var.), tomatoes (2 var.), potatoes (2 var.), barley (2 var.), rice (3 var.) and corn (1 var.), with the object of studying the interest for agriculture of seed and tuber gamma irradiation at low dose before planting. These tests were made in the laboratory, in greenhouses and in the open field, all necessary care being taken for a valuable statistical analysis of- the results. Special attention was paid to the homogeneity of plant material by controlling more particularly moisture content of seeds and the storage conditions of tubers. The observations concerned germination, growth at early stages, development phases and yield of leaves, roots and fruit. Some stimulation cases are observed. For tomatoes, it is found that stimulation cases occur at extreme moisture content and not in the range of mean moisture content which corresponds to maximum radioresistance. The demonstration of these effects is related to varieties, complementary treatments, conditions of cultivation and observation criteria. In most cases, they are short-lived and suitable modifications of seed conditioning produce, upon controls, an effect equivalent to that of irradiation. In conclusion, it seems very unlikely - considering our cultivation methods - that seed and tuber irradiation before planting could be of interest for agriculture. (authors) [fr

  1. Influence of hydrogel on germination of lettuce and onion seed at different moisture levels

    Directory of Open Access Journals (Sweden)

    Kateřina Pazderů

    2013-01-01

    Full Text Available The influence of Agrisorb (water solution 1, 3, 5 g/l on lettuce and onion seed germination was tested in different moisture conditions (30 ml and 15 ml of water in germination box. Variants with reduced water level germinated much more slowly (MGT parameter than standard variants, though differences in total germination at the end of the test were insignificant. Treated variants of lettuce seeds showed a statistically significant increase in germination energy (GE on the first day (GE1, both water levels, but a significant decrease on the second day (columns GE2, 15 ml. Higher doses of Agrisorb slowed lettuce seed germination (GE2, 30 ml, dose 5 g significantly, similarly see GE2 (15 ml, doses 1, 3, 5 g. This slowdown was apparent for GE3 (both water amount as well. A similar but insignificant effect was evident for onions. There was an influence of cultivar and seed vigour on sensitivity to water stress. The hydrogel application influenced germination of lettuce and onion seeds. Treated lettuce seeds germinated faster than non-treated control in the beginning of germination process. This effect was not recorded in case of slowly germinated onion seed lots. Although influence of Agrisorb was positive in the beginning, higher doses of hydrogel reduced germination energy of treated seed lots (for example GE2, GE4 of both crops in comparison with non-treated control. Higher doses of hydrogel caused longer MGT of lettuce and onion as well.

  2. Phantoms for IMRT dose distribution measurement and treatment verification

    International Nuclear Information System (INIS)

    Low, Daniel A.; Gerber, Russell L.; Mutic, Sasa; Purdy, James A.

    1998-01-01

    Background: The verification of intensity-modulated radiation therapy (IMRT) patient treatment dose distributions is currently based on custom-built or modified dose measurement phantoms. The only commercially available IMRT treatment planning and delivery system (Peacock, NOMOS Corp.) is supplied with a film phantom that allows accurate spatial localization of the dose distribution using radiographic film. However, measurements using other dosimeters are necessary for the thorough verification of IMRT. Methods: We have developed a phantom to enable dose measurements using a cylindrical ionization chamber and the localization of prescription isodose curves using a matrix of thermoluminescent dosimetry (TLD) chips. The external phantom cross-section is identical to that of the commercial phantom, to allow direct comparisons of measurements. A supplementary phantom has been fabricated to verify the IMRT dose distributions for pelvis treatments. Results: To date, this phantom has been used for the verification of IMRT dose distributions for head and neck and prostate cancer treatments. Designs are also presented for a phantom insert to be used with polymerizing gels (e.g., BANG-2) to obtain volumetric dose distribution measurements. Conclusion: The phantoms have proven useful in the quantitative evaluation of IMRT treatments

  3. Influence of He-Ne laser irradiation of soybean seeds on seed mycoflora, growth, nodulation, and resistance to Fusarium solani

    International Nuclear Information System (INIS)

    Ouf, S.A.; Abdel-Hady, N.F.

    1999-01-01

    Laser irradiation of soybean seeds for 3 min caused a clear reduction in the number of seed-borne fungi which became more pronounced as the irradiation time was extended. Pretreatment of the seeds with methylene blue, methyl red and carmine enhanced the effect of laser. Rhizoctonia solani, Alternaria tenuissima, Cercospora kikuchii and Colletotrichum truncatum were completely eliminated when the seeds were pretreated with a dye and irradiated for 10 min. Seed germination was stimulated on exposure of the seed to 1-min irradiation. Chlorophyll a, chlorophyll b and carotenoid content of developed plants differed, depending on the irradiation dose and dye treatment of the seeds. The number and dry mass of nodules were mostly greater (as compared to the corresponding control), when the seeds irradiated for 1 or 3 min were pretreated with methyl red, chlorophenol red, crystal violet and methylene blue. Irradiation of pre-sowing seeds greatly protected soybean stands against F. solani

  4. Antioxidant Activity of Some Extracts from GAMMA Irradiated Pomegranate (Punica granatum L.) Peel and Seed

    International Nuclear Information System (INIS)

    Soliman, I.A; Afify, S.A; Hasanin, F.R; El Sahy, K.M

    2014-01-01

    The present study aims to evaluate the antioxidant activity of pomegranate (Punica granatum L.) peel and seed (obtained as waste from juice extraction) using different solvents as diethyl ether, ethyl acetate, ethanol 50 ⁒, ethanol 80⁒: methanol 50⁒, methanol 80⁒ and distilled water. The measurements of the antioxidant activity of all extracts were carried out using a radical scavenging activity against 2,2 ' ,-diphenyl-1-picrylhydrazyl (DPPH), β-Carotene⁒linoleic acid bleaching and ferric reducing antioxidant power (FRAP). Moreover, the effect of gamma irradiation at dose levels of 3, 6 and 9 kGy on, antioxidant activity of the best pomegranate peel and seed samples that possessed highest antioxidant activity was investigated. Results showed that ethanolic 50⁒ peel extract had a higher total phenolic contents (TPC) and total flavonoid contents (TFC) in both peel and seed, (9323.17 mg gallic acid equivalent (GAE) 100 g -1 , 2998.05 mg quercetin equivalent (QE) 100 g -1 and 352.09 mg GAE 100 g -1 ,106.78 mg QE 100 g -1 dry weight (DW), respectively than other extracts. Ethanolic 50⁒ extracts showed higher antioxidant activity than other peel and seed extracts. In addition, ethanolic 50⁒ extract of irradiated pomegranate peel and seed at dose level of 6 kGy extract had higher TPC, TFC and antioxidant activity compared to other doses. Thus, ethanolic 50⁒ extract of irradiated pomegranate peel and seed at 6 kGy may be considered as a good source of natural compounds with-antioxidant activity which could be suitable as potential ingredient for food products.

  5. Methodology of quality control for brachytherapy {sup 125}I seeds

    Energy Technology Data Exchange (ETDEWEB)

    Moura, Eduardo S.; Zeituni, Carlos A.; Manzoli, Jose E.; Rostelato, Maria Elisa C.M. [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), Sao Paulo, SP (Brazil)]. E-mail: esmoura@ipen.br

    2007-07-01

    This paper presents the methodology of quality control of {sup 125}I seeds used for brachytherapy. The {sup 125}I seeds are millimeter titanium capsules widely used in permanent implants of prostate cancer, allowing a high dose within the tumour and a low dose on the surrounding tissues, with very low harm to the other tissues. Besides, with this procedure, the patients have a low impotence rate and a small incidence of urinary incontinence. To meet the medical standards, an efficient quality control is necessary, showing values with the minimum uncertainness possible, concerning the seeds dimensions and their respective activities. The medical needles are used to insert the seeds inside the prostate. The needles used in brachytherapy have an internal diameter of 1.0 mm, so it is necessary {sup 125}I seeds with an external maximum diameter of 0.85 mm. For the seeds and the spacer positioning on the planning sheet, the seeds must have a length between 4.5 and 5.0 mm. The activities must not vary more than 5% in each batch of {sup 125}I seeds. For this methodology, we used two ionization chamber detectors and one caliper. In this paper, the methodology using one control batch with 75 seeds manufactured by GE Health care Ltd is presented. (author)

  6. More accurate fitting of 125I and 103Pd radial dose functions

    International Nuclear Information System (INIS)

    Taylor, R. E. P.; Rogers, D. W. O.

    2008-01-01

    In this study an improved functional form for fitting the radial dose functions, g(r), of 125 I and 103 Pd brachytherapy seeds is presented. The new function is capable of accurately fitting radial dose functions over ranges as large as 0.05 cm≤r≤10 cm for 125 I seeds and 0.10 cm≤r≤10 cm for 103 Pd seeds. The average discrepancies between fit and calculated data are less than 0.5% over the full range of fit and maximum discrepancies are 2% or less. The fitting function is also capable of accounting for the sharp increase in g(r) (upturn) seen for some sources for r 125 I seeds and 9 103 Pd seeds using the EGSnrc Monte Carlo user-code BrachyDose. Fitting coefficients of the new function are tabulated for all 27 seeds. Extrapolation characteristics of the function are also investigated. The new functional form is an improvement over currently used fitting functions with its main strength being the ability to accurately fit the rapidly varying radial dose function at small distances. The new function is an excellent candidate for fitting the radial dose function of all 103 Pd and 125 I brachytherapy seeds and will increase the accuracy of dose distributions calculated around brachytherapy seeds using the TG-43 protocol over a wider range of data. More accurate values of g(r) for r<0.5 cm may be particularly important in the treatment of ocular melanoma

  7. Effects of low doses of gamma irradiation on pine nuts (Araucaria angustifolia)

    Energy Technology Data Exchange (ETDEWEB)

    Modolo, Debora M.; Silva, Lucia A.C.S.; Arthur, Valter, E-mail: dmmodolo@cena.usp.br, E-mail: lcasilva@cena.usp.br, E-mail: arthur@cena.usp.br [Laboratorio de Radiobiologia e Ambiente, Centro de Energia Nuclear na Agricultura (CENA/USP), Piracicaba, SP (Brazil); Harder, Marcia N.C.; Arthur, Paula B.; Arthur, Valter [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), Sao Paulo, SP (Brazil)

    2011-07-01

    The Araucaria angustifolia, is known as the Pinheiro-do-Parana, Brazilian pine, Pine, Pine Tree Monkey, emerges as the main representative of the Rain Forest, also known as Araucaria Forest, part of the Atlantic Forest biome (Decree Law 750/1993). A major problem in implementing this plan is to stand the loss of germination of seeds. The storage conditions of the seeds of species, some time have been the subject of studies by various researchers. Several studies have shown that ionizing radiation can increase the germination rate, to break dormancy and plant production, thus appearing as an alternative method to increase the production of economically important crops. Despite the Hormesis Theory have been confirmed in experiments and observations made over the years, relatively few researchers who are dedicated to the study of this phenomenon. Due to losses of germination of pine nut, the aim of this work was to study the effect of low doses of gamma radiation on pine nut. The seeds were bought locally in the city of Piracicaba and irradiated with 0 (control), 0.25, 0.50, 0.75, 10, 12, 5, 15.0 and 17.5 Gy. Subsequently the seeds were planted in a plastic cup containing vermiculite as substrate. Evaluations of the germinated seeds number and measure the size of the plants every 10 days. The results indicated that the dose of 0.25 Gy there was a greater number of plants germinated and irradiation stimulated the growth of these plants. Already a lethal dose of the seeds was 15 Gy. (author)

  8. Effects of low doses of gamma irradiation on pine nuts (Araucaria angustifolia)

    International Nuclear Information System (INIS)

    Modolo, Debora M.; Silva, Lucia A.C.S.; Arthur, Valter; Harder, Marcia N.C.; Arthur, Paula B.; Arthur, Valter

    2011-01-01

    The Araucaria angustifolia, is known as the Pinheiro-do-Parana, Brazilian pine, Pine, Pine Tree Monkey, emerges as the main representative of the Rain Forest, also known as Araucaria Forest, part of the Atlantic Forest biome (Decree Law 750/1993). A major problem in implementing this plan is to stand the loss of germination of seeds. The storage conditions of the seeds of species, some time have been the subject of studies by various researchers. Several studies have shown that ionizing radiation can increase the germination rate, to break dormancy and plant production, thus appearing as an alternative method to increase the production of economically important crops. Despite the Hormesis Theory have been confirmed in experiments and observations made over the years, relatively few researchers who are dedicated to the study of this phenomenon. Due to losses of germination of pine nut, the aim of this work was to study the effect of low doses of gamma radiation on pine nut. The seeds were bought locally in the city of Piracicaba and irradiated with 0 (control), 0.25, 0.50, 0.75, 10, 12, 5, 15.0 and 17.5 Gy. Subsequently the seeds were planted in a plastic cup containing vermiculite as substrate. Evaluations of the germinated seeds number and measure the size of the plants every 10 days. The results indicated that the dose of 0.25 Gy there was a greater number of plants germinated and irradiation stimulated the growth of these plants. Already a lethal dose of the seeds was 15 Gy. (author)

  9. Effect of gamma-irradiation on rice seed DNA. Pt. 1. Yield and molecular size of DNA extracted from irradiated rice seeds

    International Nuclear Information System (INIS)

    Kawamura, Yoko; Konishi, Akihiro; Yamada, Takashi; Saito, Yukio

    1995-01-01

    The effect of gamma-irradiation on the DNA of hulled rice seeds was investigated. The cetyltrimethylammonium bromide (CTAB) method was preferred for the extraction of DNA from rice seeds because of its high quality and good yield. The yield of DNA that was determined by gel electrophoresis, decreased as the irradiation dose increased from 1 kGy. DNA extracted from rice seeds irradiated with a 30 kGy dose showed a molecular size of less than 20 kb, while that from unirradiated rice showed more than 100 kb in electrophoretic profiles. It can be assumed that the decrease in yield was mainly induced by the crosslinking between protein and DNA, and the reduction in molecular size was induced by double-strand breaks. (J.P.N.)

  10. EFFECTS OF SEED IRRADIATION ON 14C FIXATION AND ANTIOXIDANT ACTIVITY OF VITAMIN C AND TOTAL PHENOLS OF CANOLA LEAVES

    International Nuclear Information System (INIS)

    KAMEL, H.A.

    2008-01-01

    Seeds of canola were gamma irradiated with doses of 10, 25, 50, 100 and 200 Gy then cultivated in 30 cm plastic pots containing 7 kg clay soil. After 45 days of cultivation, plants were used to measure 14 C fixation capacity, vitamin C, total phenol, free proline and peroxidase activity in addition to the antioxidant activity. The results showed decrease in the chlorophyll content and 14 C fixation at all gamma doses. Irradiation of canola seeds caused significant reduction in vitamin C and phenol content, while significant increase was occurred in free proline and peroxidase activity. Antioxidant activity of vitamin C was higher than that of phenols at all doses used

  11. Effects of 60Co γ-rays irradiation on seed growth of ground-cover chrysanthemum

    International Nuclear Information System (INIS)

    Ge Weiya; Wang Tiantian; Yang Shuhua; Zhao Ying; Ge Hong; Chen Lin

    2011-01-01

    The seeds of ground-cover chrysanthemum were used to study the effects of different doses of 60 Co γ-rays irradiation(10-50 Gy) on seed germination and physiological characteristics. The results showed that the rate of seed germination and seedling survival decreased significantly with the irradiation doses. With the increase of irradiation dose to above 20 Gy, the content of malondialdehyde (MDA) and activity of peroxidase (POD) in seedlings significantly increased. The similar trends were found in the activities of superoxide dismutase (SOD) and glutathione reductase (GR). Catalase (CAT) activity increased at doses lower than 20 Gy, and then decreased at the higher doses, whereas ascorbate peroxidase (APX) activity did not alter except for 40 Gy. It is concluded that the suitable irradiation dose of mutation breeding is 20 Gy for the seeds of ground-cover chrysanthemum. Although 60 Co γ-rays irradiation resulted in damage of membrane lipid peroxidation in the survival seedlings, the increased activity of CAT and POD could protect them against the damage. (authors)

  12. Influence of gamma-radiation on the nutritional and functional qualities of lotus seed flour.

    Science.gov (United States)

    Bhat, Rajeev; Sridhar, Kandikere Ramaiah; Karim, Alias A; Young, Chiu C; Arun, Ananthapadmanabha B

    2009-10-28

    In the present study, we investigated the physicochemical and functional properties of lotus seed flour exposed to low and high doses of gamma-radiation (0-30 kGy; the dose recommended for quarantine and hygienic purposes). The results indicated raw seed flour to be rich in nutrients with minimal quantities of antinutritional factors. Irradiation resulted in a dose-dependent increase in some of the proximal constituents. The raw and gamma-irradiated seeds meet the Food and Agricultural Organization-World Health Organization recommended pattern of essential amino acids. Some of the antinutritional factors (phytic acid, total phenolics, and tannins) were lowered with gamma-irradiation, while the seed flours were devoid of lectins, L-3,4-dihydroxyphenylalanine, and polonium-210. The functional properties of the seed flour were significantly improved with gamma-radiation. gamma-radiation selectively preserved or improved the desired nutritional and functional traits of lotus seeds, thus ensuring a safe production of appropriate nutraceutically valued products.

  13. A Radiation Badge Survey for Family Members Living With Patients Treated With a 103Pd Permanent Breast Seed Implant

    International Nuclear Information System (INIS)

    Keller, Brian M.; Pignol, Jean-Philippe; Rakovitch, Eileen; Sankreacha, Raxa; O'Brien, Peter

    2008-01-01

    Purpose: Sixty-seven patients with early-stage breast cancer were treated in a Phase I/II clinical trial using a 103 Pd permanent breast seed implant as adjuvant radiotherapy after breast-conserving surgery. We report the dose received by family members living with these patients and compare measured doses with theoretical worst-case scenario estimates. Methods and Materials: Exposure-rate measurements were taken at 1 m from the patient by using a calibrated low-energy survey meter. Landauer (Landauer Inc., Glenwood, IL) Luxel badges, with sensitivity of 0.01 mSv, were given to family members to wear after the implantation. Badge readings for 33 spouses and 28 other family members were used to estimate effective doses, and these were compared with theory. Results: Average preimplantation planning target volume from computed tomography was 50.3 ml (range, 18.0-96.7 ml), and average preimplantation distance between the skin and the most anterior planning target volume margin was 0.57 cm. The average maximum exposure rate was measured to be 2.4 ± 1.1 mR/h, and average measured dose to a spouse was 0.99 ± 1.0 mSv. The calculated exposure rates and spousal doses using preimplantation computed tomography scan data overestimated those measured. Average measured family member dose (excluding spouses) was 0.20 ± 0.58 mSv. Conclusions: Based on measured and calculated spousal doses, a permanent breast seed implant using 103 Pd is safe for the public. However, it is recommended that extra precautions in the way of a breast patch be used when patients with an implant will be in the vicinity of toddlers or pregnant women

  14. Fast dose kernel interpolation using Fourier transform with application to permanent prostate brachytherapy dosimetry.

    Science.gov (United States)

    Liu, Derek; Sloboda, Ron S

    2014-05-01

    Boyer and Mok proposed a fast calculation method employing the Fourier transform (FT), for which calculation time is independent of the number of seeds but seed placement is restricted to calculation grid points. Here an interpolation method is described enabling unrestricted seed placement while preserving the computational efficiency of the original method. The Iodine-125 seed dose kernel was sampled and selected values were modified to optimize interpolation accuracy for clinically relevant doses. For each seed, the kernel was shifted to the nearest grid point via convolution with a unit impulse, implemented in the Fourier domain. The remaining fractional shift was performed using a piecewise third-order Lagrange filter. Implementation of the interpolation method greatly improved FT-based dose calculation accuracy. The dose distribution was accurate to within 2% beyond 3 mm from each seed. Isodose contours were indistinguishable from explicit TG-43 calculation. Dose-volume metric errors were negligible. Computation time for the FT interpolation method was essentially the same as Boyer's method. A FT interpolation method for permanent prostate brachytherapy TG-43 dose calculation was developed which expands upon Boyer's original method and enables unrestricted seed placement. The proposed method substantially improves the clinically relevant dose accuracy with negligible additional computation cost, preserving the efficiency of the original method.

  15. Effect of gamma irradiation on some physiological processes during maiz. seed germination

    Energy Technology Data Exchange (ETDEWEB)

    Kerin, V; Ilieva, T [Vissh Selskostopanski Inst., Plovdiv (Bulgaria)

    1976-01-01

    The investigation was carried out with the SK/sub 4/ and Knezha 2L-403 hybrids. Dry seeds were irradiated by ..gamma..-rays in doses of 500 R, 750 R and 1000 R radioactive cesium 137. The effect of the individual ..gamma..-ray doses on sprout and root growth, respiration rate and peroxidase activity was followed up. Results showed that seed irradiation by a 500R dose had a stimulating effect on sprout and root growth, while the 750 R and 1000 R did not differ significantly from the ccntrol. Seed irradiation by 500 R reduced the respiration rate of the roots and sprouts, while both treatments with higher doses gave results similar to the control. The changes in the respiration enzyme peroxidase were in correlation with the changes in respiration rate.

  16. Seed-borne pathogens and electrical conductivity of soybean seeds

    Directory of Open Access Journals (Sweden)

    Adriana Luiza Wain-Tassi

    2012-02-01

    Full Text Available Adequate procedures to evaluate seed vigor are important. Regarding the electrical conductivity test (EC, the interference in the test results caused by seed-borne pathogens has not been clarified. This research was carried out to study the influence of Phomopsis sojae (Leh. and Colletotrichum dematium (Pers. ex Fr. Grove var. truncata (Schw. Arx. fungi on EC results. Soybean seeds (Glycine max L. were inoculated with those fungi using potato, agar and dextrose (PDA medium with manitol (-1.0 MPa and incubated for 20 h at 25 °C. The colony diameter, index of mycelial growth, seed water content, occurrence of seed-borne pathogens, physiological potential of the seeds, measured by germination and vigor tests (seed germination index, cold test, accelerated aging and electrical conductivity, and seedling field emergence were determined. The contents of K+, Ca2+, and Mg2+ in the seed and in the soaking solution were also determined. A complete 2 × 4 factorial design with two seed sizes (5.5 and 6.5 mm and four treatments (control, seeds incubated without fungi, seeds incubated with Phomopsis and seeds incubated with Colletotrichum were used with eight (5.5 mm large seeds and six (6.5 mm large seeds replications. All seeds submitted to PDA medium had their germination reduced in comparison to the control seeds. This reduction was also observed when seed vigor and leached ions were considered. The presence of Phomopsis sojae fungus in soybean seed samples submitted to the EC test may be the cause of misleading results.

  17. Radiation dose measurement in gastrointestinal studies

    International Nuclear Information System (INIS)

    Sulieman, A.; Elzaki, M.; Kappas, C.; Theodorou, K.

    2011-01-01

    Barium studies investigations (barium swallow, barium meal and barium enema) are the basic routine radiological examination, where barium sulphate suspension is introduced to enhance image contrast of gastrointestinal tracts. The aim of this study was to quantify the patients' radiation doses during barium studies and to estimate the organ equivalent dose and effective dose with those procedures. A total of 33 investigations of barium studies were measured by using thermoluminescence dosemeters. The result showed that the patient entrance surface doses were 12.6±10, 44.5±49 and 35.7±50 mGy for barium swallow, barium meal, follow through and enema, respectively. Effective doses were 0.2, 0.35 and 1.4 mSv per procedure for barium swallow, meal and enema respectively. Radiation doses were comparable with the previous studies. A written protocol for each procedure will reduce the inter-operator variations and will help to reduce unnecessary exposure. (authors)

  18. Measurement of gamma radiation doses in nuclear power plant environment

    International Nuclear Information System (INIS)

    Bochvar, I.A.; Keirim-Markus, I.B.; Sergeeva, N.A.

    1976-01-01

    Considered are the problems of measuring gamma radiation dose values and the dose distribution in the nuclear power plant area with the aim of estimating the extent of their effect on the population. Presented are the dosimeters applied, their distribution throughout the controlled area, time of measurement. The distribution of gamma radiation doses over the controlled area and the dose alteration with the increase of the distance from the release source are shown. The results of measurements are investigated. The conclusion is made that operating nuclear power plants do not cause any increase in the gamma radiation dose over the area. Recommendations for clarifying the techniques for using dose-meters and decreasing measurement errors are given [ru

  19. Identification of gamma irradiated pulse seed (Lens sp.) based on germination test

    International Nuclear Information System (INIS)

    Chaudhuri, Sadhan K.

    2001-01-01

    The germination test of pulse seed provided a reliable method for the identification of lentil seeds that had been subjected to irradiation. Root and shoot lengths were found more sensitive to the gamma irradiation than the germination percentages. The critical dose that prevented the root elongation varied from 0.1 kGy to 0.5 kGy. Germination percentage was reduced drastically above 0.2 kGy. Above 1.0 kGy dose, the lentil seeds did not germinate. The sensitivity of lentil seeds to gamma irradiation was inversely proportional to moisture content of the seeds. In addition, storage period up to 12 months had little effect on irradiation the induced reduction of root and shoot lengths. Thus, this test can determine the difference between irradiated and non-irradiated lentil seeds even 12 months after gamma irradiation. (author)

  20. Distribution of implanted ions in seeds and roots of mung bean

    International Nuclear Information System (INIS)

    Liu Donghua; Wang Wei; Jiang Wusheng; Zhang Zhixiang; Hou Wenqiang; Guo Ximing; Li Yi

    1998-01-01

    Doses of 1 x 10 16 , and 2 x 10 16 cm -2 and 1 x 10 16 , 2 x 10 16 , 3 x 10 16 and 3.6 x 10 16 cm -2 for iron and copper ions are implanted in dry seeds of mung bean, respectively. The results show that the accumulated-copper and -iron ion amounts in the seeds and roots vary with different doses of ion beam, and the fresh and dry weights of the roots decrease progressively with increasing iron and copper doses, except the treatment of 1 x 10 16 Cu + ions/cm 2 , and the accumulated-copper and -iron ion amounts in the seeds of the different test groups can be correlated with the ion distribution in the roots

  1. An experimental palladium-103 seed (OptiSeedexp) in a biocompatible polymer without a gold marker: Characterization of dosimetric parameters including the interseed effect

    International Nuclear Information System (INIS)

    Abboud, F.; Scalliet, P.; Vynckier, S.

    2008-01-01

    Permanent implantation of 125 I (iodine) or 103 Pd (palladium) sources is a popular treatment option in the management of early stage prostate cancer. New sources are being developed, some of which are being marketed for different clinical applications. A new technique of adjuvant stereotactic permanent seed breast implant, similar to that used in the treatment of prostate cancer, has been proposed by [N. Jansen et al., Int. J. Radiat. Oncol. Biol. Phys. 67, 1052-1058 (2007)] with encouraging results. The presence of artifacts from the metallic seeds, however, can disturb follow-up imaging. The development of plastic seeds has reduced these artifacts. This paper presents a feasibility study of the advantages of palladium-103 seeds, encapsulated with a biocompatible polymer, for future clinical applications, and on the effect of the gold marker on the dosimetric characteristics of such seeds. Experimental palladium seeds, OptiSeed exp , were manufactured by International Brachytherapy (IBt), Seneffe, Belgium, from a biocompatible polymer, including the marker. Apart from the absence of a gold marker, the studied seed has an identical design to the OptiSeed 103 [Phys. Med. Biol. 50, 1493-1504 (2005)]; [Appl. Radiat. Isot. 63, 311-321 (2005)]. Polymer encapsulation was preferred by IBt in order to reduce the quantity of radioactive material needed for a given dose rate and to reduce the anisotropy of the radiation field around the seed. In addition, this design is intended to decrease the interseed effects that can occur as a result of the marker and the encapsulation. Dosimetric measurements were performed using LiF thermoluminescent dosimeters (1 mm 3 ) in solid water phantoms (WT1). Measured data were compared to Monte Carlo simulated data in solid water using the MCNP code, version 4C. Updated cross sections [Med. Phys. 30, 701-711 (2003)] were used. As the measured and calculated data were in agreement, Monte Carlo calculations were then performed in liquid water

  2. Measured dose to ovaries and testes from Hodgkin's fields and determination of genetically significant dose

    International Nuclear Information System (INIS)

    Niroomand-Rad, A.; Cumberlin, R.

    1993-01-01

    The purpose of this study was to determine the genetically significant dose from therapeutic radiation exposure with Hodgkin's fields by estimating the doses to ovaries and testes. Phantom measurements were performed to verify estimated doses to ovaries and testes from Hodgkin's fields. Thermoluminescent LiF dosimeters (TLD-100) of 1 x 3 x 3 mm 3 dimensions were embedded in phantoms and exposed to standard mantle and paraaortic fields using Co-60, 4 MV, 6 MV, and 10 MV photon beams. The results show that measured doses to ovaries and testes are about two to five times higher than the corresponding graphically estimated doses for Co-60 and 4 MVX photon beams as depicted in ICRP publication 44. In addition, the measured doses to ovaries and testes are about 30% to 65% lower for 10 MV photon beams than for their corresponding Co-60 photon beams. The genetically significant dose from Hodgkin's treatment (less than 0.01 mSv) adds about 4% to the genetically significant dose contribution to medical procedures and adds less than 1% to the genetically significant dose from all sources. Therefore, the consequence to society is considered to be very small. The consequences for the individual patient are, likewise, small. 28 refs., 3 figs., 5 tabs

  3. Radiation Dose Measurement Using Chemical Dosimeters

    International Nuclear Information System (INIS)

    Lee, Min Sun; Kim, Eun Hee; Kim, Yu Ri; Han, Bum Soo

    2010-01-01

    The radiation dose can be estimated in various ways. Dose estimates can be obtained by either experiment or theoretical analysis. In experiments, radiation impact is assessed by measuring any change caused by energy deposition to the exposed matter, in terms of energy state (physical change), chemical production (chemical change) or biological abnormality (biological change). The chemical dosimetry is based on the implication that the energy deposited to the matter can be inferred from the consequential change in chemical production. The chemical dosimetry usually works on the sample that is an aqueous solution, a biological matter, or an organic substance. In this study, we estimated absorbed doses by quantitating chemical changes in matter caused by radiation exposure. Two different chemical dosimeters, Fricke and ECB (Ethanol-Chlorobenzene) dosimeter, were compared in several features including efficacy as dose indicator and effective dose range

  4. Nutritional quality evaluation of velvet bean seeds (Mucuna pruriens) exposed to gamma irradiation.

    Science.gov (United States)

    Bhat, Rajeev; Sridhar, Kandikere R; Seena, Sahadevan

    2008-06-01

    Effects of gamma irradiation on Mucuna pruriens seeds at various doses (0, 2.5, 5, 7.5, 10, 15 and 30 kGy) on the proximate composition, mineral constituents, amino acids, fatty acids and functional properties were investigated. Gamma irradiation resulted in a significant increase of crude protein at all doses, while the crude lipid, crude fibre and ash showed a dose-dependent decrease. Raw Mucuna seeds were rich in minerals (potassium, phosphorus, calcium, magnesium, iron and selenium). Sodium, copper and manganese were significantly decreased on irradiation at all the doses, while magnesium and iron showed a significant decrease only above 10 kGy. The essential amino acids of raw and gamma-irradiated Mucuna seeds were comparable with the FAO/WHO recommended pattern. A significant increase of in vitro protein digestibility was seen in seeds irradiated at 30 kGy. High amounts of unsaturated fatty acids in Mucuna seeds decreased significantly after irradiation. However, linoleic acid was not present in raw seeds but detected after irradiation and it was elevated to high level at 30 kGy. Behenic acid, a major anti-nutritional factor, was reduced significantly on irradiation, indicating the positive effect of gamma irradiation on Mucuna seeds. Significant enhancement in the water absorption and oil absorption capacities, protein solubility, emulsion activity and improvement in the gelation capacity was recorded after irradiation. Results of the present investigation reveal that application of gamma irradiation does not affect the overall nutritional composition and can be used as an effective method of preservation of Mucuna seed and their products.

  5. Studying and measuring the gamma radiation doses in Homs city

    International Nuclear Information System (INIS)

    Sofaan, A. H.

    2001-01-01

    The gamma radiation dose was measured in Homs city by using many portable dosimeters (electronic dosimeter and Geiger-Muller). The measurements were carried out in the indoor and outdoor buildings, for different time period, through one year (1999-2000). High purity germanium detector with low back ground radiation (HpGe) was used to determine radiation element contained in some building and the surrounding soil. The statistical analysis laws were applied to make sure that the measured dose distribution around average value is normal distribution. The measurement indicates that the gamma indoor dose varies from 312μSv/y to 511μSv/y, with the average annual dose of 385μSv/y. However the gamma outdoor dose rate varies from 307μSv/y to 366μSv/y with an average annual dose 385μSv/y. The annual outdoor gamma radiation dose is about %16 lower than the outdoor dose in Homs City. These measurements have indicated that environmental gamma doses in Homs City are relatively low. This is because that most of the soils and rocks in the area are limestone. (author)

  6. Thermoluminescent dose measurements on board Salyut type orbital stations

    International Nuclear Information System (INIS)

    Akatov, Yu.A.; Arkhangelskij, V.V.; Aleksandrov, A.P.

    1984-06-01

    A small, vibration- and shock-resistant thermoluminescent dosemeter (TLD) system - named PILLE - was developed for orbital stations at the Central Research Institute for Physics, Hungary, to measure the cosmic radiation dose on-board. The first on-board measurements with this system were performed by B. Farkas, the Hungarian astronaut, on the Salyut-6 space station in 1980. The same instrument was used by other crews in the following years. Doses measured at different sites in Salyut-6 are presented. The dose rates varied from 0.7 to 0.11 mGy.day -1 . After the first cosmic measurements, the system was further developed. The minimum detectable dose of the new TLD system is 1 μGy, i.e. less by one order of magnitude than that of the former system. The self-irradiation dose rate of the TLD bulbs is also reduced by more than an order of magnitude to 10 nGy.h -1 , by use of potassium-free glass for the bulb envelope. This new type of PILLE TLD system is currently on-board Salyut-7. The dose rates (0.12-0.23 mGy.day -1 ) measured in 1983 are presented in detail. (author)

  7. High speed measurement of corn seed viability using hyperspectral imaging

    Science.gov (United States)

    Ambrose, Ashabahebwa; Kandpal, Lalit Mohan; Kim, Moon S.; Lee, Wang-Hee; Cho, Byoung-Kwan

    2016-03-01

    Corn is one of the most cultivated crops all over world as food for humans as well as animals. Optimized agronomic practices and improved technological interventions during planting, harvesting and post-harvest handling are critical to improving the quantity and quality of corn production. Seed germination and vigor are the primary determinants of high yield notwithstanding any other factors that may play during the growth period. Seed viability may be lost during storage due to unfavorable conditions e.g. moisture content and temperatures, or physical damage during mechanical processing e.g. shelling, or over heating during drying. It is therefore vital for seed companies and farmers to test and ascertain seed viability to avoid losses of any kind. This study aimed at investigating the possibility of using hyperspectral imaging (HSI) technique to discriminate viable and nonviable corn seeds. A group of corn samples were heat treated by using microwave process while a group of seeds were kept as control group (untreated). The hyperspectral images of corn seeds of both groups were captured between 400 and 2500 nm wave range. Partial least squares discriminant analysis (PLS-DA) was built for the classification of aged (heat treated) and normal (untreated) corn seeds. The model showed highest classification accuracy of 97.6% (calibration) and 95.6% (prediction) in the SWIR region of the HSI. Furthermore, the PLS-DA and binary images were capable to provide the visual information of treated and untreated corn seeds. The overall results suggest that HSI technique is accurate for classification of viable and non-viable seeds with non-destructive manner.

  8. Monte Carlo study of LDR seed dosimetry with an application in a clinical brachytherapy breast implant.

    Science.gov (United States)

    Furstoss, C; Reniers, B; Bertrand, M J; Poon, E; Carrier, J-F; Keller, B M; Pignol, J P; Beaulieu, L; Verhaegen, F

    2009-05-01

    A Monte Carlo (MC) study was carried out to evaluate the effects of the interseed attenuation and the tissue composition for two models of 125I low dose rate (LDR) brachytherapy seeds (Medi-Physics 6711, IBt InterSource) in a permanent breast implant. The effect of the tissue composition was investigated because the breast localization presents heterogeneities such as glandular and adipose tissue surrounded by air, lungs, and ribs. The absolute MC dose calculations were benchmarked by comparison to the absolute dose obtained from experimental results. Before modeling a clinical case of an implant in heterogeneous breast, the effects of the tissue composition and the interseed attenuation were studied in homogeneous phantoms. To investigate the tissue composition effect, the dose along the transverse axis of the two seed models were calculated and compared in different materials. For each seed model, three seeds sharing the same transverse axis were simulated to evaluate the interseed effect in water as a function of the distance from the seed. A clinical study of a permanent breast 125I implant for a single patient was carried out using four dose calculation techniques: (1) A TG-43 based calculation, (2) a full MC simulation with realistic tissues and seed models, (3) a MC simulation in water and modeled seeds, and (4) a MC simulation without modeling the seed geometry but with realistic tissues. In the latter, a phase space file corresponding to the particles emitted from the external surface of the seed is used at each seed location. The results were compared by calculating the relevant clinical metrics V85, V100, and V200 for this kind of treatment in the target. D90 and D50 were also determined to evaluate the differences in dose and compare the results to the studies published for permanent prostate seed implants in literature. The experimental results are in agreement with the MC absolute doses (within 5% for EBT Gafchromic film and within 7% for TLD-100

  9. Effect of γ-irradiation on bioactivity, fatty acid compositions and volatile compounds of clary sage seed (Salvia sclarea L.).

    Science.gov (United States)

    Yalcin, Hasan; Ozturk, Ismet; Tulukcu, Eray; Sagdic, Osman

    2011-09-01

    Clary sage seeds (Salvia sclarea L.) were obtained from plants cultivated, and 2.5, 4.0, 5.5, and 7.0 kGy doses of γ-irradiation were applied to the clary sage seeds. They were then analyzed for their protein, ash, oil and dry matter contents, and fatty acid composition. Additionally, the total phenolic contents, antiradical, antioxidant activities, and volatile compounds of the clary sage seed extract were determined. There was no significant difference in protein content. However, the moisture, oil, and ash contents of the samples were affected by irradiation. While the 7 kGy dose had a positive effect on the total phenolic content and antiradical activity of the sage seed extract, all doses have negative effects on the antioxidant activity of the sage seed. The main fatty acid of the sage seed was remarkably found as α-linolenic acid. The four irradiation levels caused significant differences in fatty acid composition by affecting all fatty acids except palmitic, palmitoleic, and eicosenoic acids. The dominant volatile compounds of control sage seed were found as β-pinene (18.81%) and limonene (15.60%). Higher doses of the irradiation decreased volatile components of sage seed. Clary sage seed including high omega-3 can be irradiated with low doses (≤ 2.5 kGy) of γ-irradiation. Clary sage is one of the most popular Salvia species in Turkey and many countries. Clary sage seed has approximately 29% oil content and this oil contains >50% of α-linolenic acid. γ-Irradiation is widely applied in the preservation of spice quality. The present study shows that the antioxidant activity of the clary sage seed is decreased by γ-irradiation. Additionally, higher doses of irradiation also decreased the volatile components of sage seed. Therefore, we suggest that clary sage seed which includes high levels of omega-3 should be irradiated with low doses (≤ 2.5 kGy) of γ-irradiation. © 2011 Institute of Food Technologists®

  10. Doses de potássio na produção e qualidade de sementes de alface Potassium rates in the lettuce seed production and quality

    Directory of Open Access Journals (Sweden)

    Cristiaini Kano

    2006-09-01

    Full Text Available Devido à falta de informações relacionadas à adubação em hortaliças cojo objetivo é a produção de sementes, em culturas em que ocorre um aumento no ciclo, nota-se a necessidade de se estudar a influência de doses de nutrientes que proporcionem aumento de produtividade e obtenção de sementes de melhor qualidade. Este trabalho teve o objetivo de avaliar o efeito de diferentes doses de adubo potássico na produção e qualidade de sementes de alface cultivar 'Verônica'. O delineamento experimental utilizado foi o de blocos casualizados, com cinco tratamentos (0,0; 1,0; 1,5; 2,0 e 2,5 g planta- 1 de K2O e seis repetições. Os dados foram submetidos à análise de variância e regressão. Pelos resultados obtidos pode-se concluir que as doses de K2O avaliadas resultaram em aumento linear na produção (massa e número de sementes, mas não afetaram a qualidade fisiológica (germinação e vigor das mesmas.There exist a lack of information about the fertilization of vegetables where occurr an increase of the vegetative cycle, when the seeds production is the final purpose. The influence of potassium rates was evaluated in lettuce cultivar Verônica for yield and quality of seeds. The experiment was conducted in randomized complete blocks, with five treatments (0,0; 1,0; 1,5; 2,0 e 2,5g plant-1 of K2O and six replications. The data were submitted to the variance analysis and to the regression analysis. The K2O rates resulted in a linear increase in the seed yield (mass and number but did not affect the seed quality.

  11. Neutron irradiation of seeds. Report of a study-group meeting held in Vienna, 25-29 July 1966 and of a working group meeting held in Vienna, 12-16 December 1966

    Energy Technology Data Exchange (ETDEWEB)

    1967-09-01

    Neutrons are a valuable type of ionizing radiation for seed irradiation and radiobiological studies and for inducing mutations in crop plants. In experiments where neutrons are used in research reactors for seed irradiation it is difficult to measure the dose accurately and therefore to establish significant comparisons between experimental results obtained in various reactors and between repeated experiments in the same reactor. A further obstacle lies in the nature and response of the seeds themselves and the variety of ways in which they are exposed in reactors. The International Atomic Energy Agency decided to initiate international efforts to improve and standardize methods of exposing seeds in research reactors and of measuring and reporting the neutron dose. For this purpose, an International Neutron Seed Irradiation Programme has been established. The present report aims to give a brief but comprehensive picture of the work so far done in this programme. Refs, figs and tabs.

  12. Assessment of I-125 seed implant accuracy when using the live-planning technique for low dose rate prostate brachytherapy

    Directory of Open Access Journals (Sweden)

    Moorrees Joshua

    2012-11-01

    Full Text Available Abstract Background Low risk prostate cancers are commonly treated with low dose rate (LDR brachytherapy involving I-125 seeds. The implementation of a ‘live-planning’ technique at the Royal Adelaide Hospital (RAH in 2007 enabled the completion of the whole procedure (i.e. scanning, planning and implant in one sitting. ‘Live-planning’ has the advantage of a more reliable delivery of the planned treatment compared to the ‘traditional pre-plan’ technique (where patient is scanned and planned in the weeks prior to implant. During live planning, the actual implanted needle positions are updated real-time on the treatment planning system and the dosimetry is automatically recalculated. The aim of this investigation was to assess the differences and clinical relevance between the planned dosimetry and the updated real-time implant dosimetry. Methods A number of 162 patients were included in this dosimetric study. A paired t-test was performed on the D90, V100, V150 and V200 target parameters and the differences between the planned and implanted dose distributions were analysed. Similarly, dosimetric differences for the organs at risk (OAR were also evaluated. Results Small differences between the primary dosimetric parameters for the target were found. Still, the incidence of hotspots was increased with approximately 20% for V200. Statistically significant increases were observed in the doses delivered to the OAR between the planned and implanted data; however, these increases were consistently below 3% thus probably without clinical consequences. Conclusions The current study assessed the accuracy of prostate implants with I-125 seeds when compared to initial plans. The results confirmed the precision of the implant technique which RAH has in place. Nevertheless, geographical misses, anatomical restrictions and needle displacements during implant can have repercussions for centres without live-planning option if dosimetric changes are not

  13. Ionization chamber for high dose measurements

    International Nuclear Information System (INIS)

    Rodrigues Junior, Ary de Araujo

    2005-01-01

    Industrial gamma irradiators facilities are designed for processing large amounts of products, which are exposed to large doses of gamma radiation. The irradiation, in industrial scale, is usually carried out in a dynamic form, where the products go through a 60 Co gamma source with activity of TBq to P Bq (k Ci to MCi). The dose is estimated as being directly proportional to the time that the products spend to go through the source. However, in some situations, mainly for research purposes or for validation of customer process following the ISO 11137 requirements, it is required to irradiate small samples in a static position with fractional deliver doses. The samples are put inside the irradiation room at a fixed distance from the source and the dose is usually determined using dosimeters. The dose is only known after the irradiation, by reading the dosimeter. Nevertheless, in the industrial irradiators, usually different kinds of products with different densities go through between the source and the static position samples. So, the dose rate varies in function of the product density. A suitable methodology would be to monitor the samples dose in real time, measuring the dose on line with a radiation detector, which would improve the dose accuracy and avoid the overdose. A cylindrical ionization chamber of 0.9 cm 3 has been developed for high-doses real-time monitoring, during the sample irradiation at a static position in a 60 Co gamma industrial plant. Nitrogen and argon gas at pressure of 10 exp 5 Pa (1 bar) was utilized to fill the ionization chamber, for which an appropriate configuration was determined to be used as a detector for high-dose measurements. To transmit the signal generated in the ionization chamber to the associated electronic and processing unit, a 20 m mineral insulated cable was welded to the ionization chamber. The signal to noise ratio produced by the detector was about 100. The dosimeter system was tested at a category I gamma

  14. Measurements of the personal dose equivalent

    International Nuclear Information System (INIS)

    Scarlat, F.; Scarisoreanu, A.; Badita, E.; Oane, M.; Mitru, E.

    2008-01-01

    Full text: The paper presents the results of measurements related to the personal dose equivalent in the rooms adjacent to NILPRP 7 MeV linear accelerator, by means of the secondary standard chamber T34035 Hp(10). The chamber was calibrated by PTB at S- 137 Cs (E av = 661.6 keV, T 1/2 11050 days) and has N H = 3.17x10 6 Sv/C calibration factor for the personal dose equivalent, Hp(10), at a depth of 10 mm in climatic reference conditions. The measurements were made for the two operation mode of the 7 MeV linac: electrons and bremsstrahlung

  15. Biological effects of low energy nitrogen ion implantation on Jatropha curcas L. seed germination

    International Nuclear Information System (INIS)

    Xu Gang; Wang Xiaoteng; Gan Cailing; Fang Yanqiong; Zhang Meng

    2012-01-01

    Highlights: ► We analyzed biological effects of N + implantation on dry Jatropha curcas seed. ► N + implantation greatly decreased seedling survival rate. ► At doses beyond 15 × 10 16 ion cm −2 , biological repair took place. ► CAT was essential for H 2 O 2 removal. POD mainly functioned as seed was severely hurt. ► HAsA–GSH cycle mainly contributed to the regeneration of HAsA. - Abstract: To explore the biological effects of nitrogen ion beam implantation on dry Jatropha curcas seed, a beam of N + with energy of 25 keV was applied to treat the dry seed at six different doses. N + beam implantation greatly decreased germination rate and seedling survival rate. The doses within the range of 12 × 10 16 to 15 × 10 16 ions cm −2 severely damaged the seeds: total antioxidant capacity (TAC), germination rate, seedling survival rate, reduced ascorbate acid (HAsA) and reduced glutathione (GSH) contents, and most of the tested antioxidases activity (i.e. catalase (CAT), ascorbate peroxidase (APX) and superoxide dismutase (SOD)) reached their lowest levels. At a dose of 18 × 10 16 ion cm −2 , biological repair took place: moderate increases were found in TAC, germination rate, seedling survival rate, HAsA and GSH contents, and some antioxidant enzyme activities (i.e. CAT, APX, SOD and GPX). The dose of 18 × 10 16 ions cm −2 may be the optimum dose for use in dry J. curcas seed mutation breeding. CAT, HAsA and GSH contributed to the increase of TAC, but CAT was the most important. POD performed its important role as seed was severely damaged. The main role of the HAsA–GSH cycle appeared to be for regeneration of HAsA.

  16. Surface dose extrapolation measurements with radiographic film

    International Nuclear Information System (INIS)

    Butson, Martin J; Cheung Tsang; Yu, Peter K N; Currie, Michael

    2004-01-01

    Assessment of surface dose delivered from radiotherapy x-ray beams for optimal results should be performed both inside and outside the prescribed treatment fields. An extrapolation technique can be used with radiographic film to perform surface dose assessment for open field high energy x-ray beams. This can produce an accurate two-dimensional map of surface dose if required. Results have shown that the surface percentage dose can be estimated within ±3% of parallel plate ionization chamber results with radiographic film using a series of film layers to produce an extrapolated result. Extrapolated percentage dose assessment for 10 cm, 20 cm and 30 cm square fields was estimated to be 15% ± 2%, 29% ± 3% and 38% ± 3% at the central axis and relatively uniform across the treatment field. The corresponding parallel plate ionization chamber measurements are 16%, 27% and 37%, respectively. Surface doses are also measured outside the treatment field which are mainly due to scattered electron contamination. To achieve this result, film calibration curves must be irradiated to similar x-ray field sizes as the experimental film to minimize quantitative variations in film optical density caused by varying x-ray spectrum with field size. (note)

  17. Gamma radiation sensitivity in tomato tree and response of plants proceeding from salinity irradiated seeds

    International Nuclear Information System (INIS)

    Colaco, Waldeciro; Bidjeke, Raoul; Fleming, Peter M.

    2000-01-01

    Preliminary experiments were conducted to evaluate the radiosensitivity of tomato {Lycopersicon esculentum L. cultivars IPA-6, IPA-8, and Lycopersicum hirsutum glabratum - } to gamma rays from a 60 Co source, considering future induced mutation studies aiming at the improvement of plant salinity tolerance. Sets of dry seeds were exposed to gamma radiation doses (300 - 600 Gy and 100-400 Gy) and compared to a control without irradiation (0 Gy) under greenhouse conditions. The radiosensitivity was initially evaluated through germination of irradiated dry seeds determined at 13 and 30 days after irradiation and also through seedling survival. Seed germination was delayed by gamma irradiation and especially reduced at higher doses (300- 600 Gy). Survival of tomato plants was decreased with increased dose of radiation and was reduced by < 16% at the 300-600 Gy doses. Growth of plants was enhanced at low doses of gamma rays; higher doses reduced plant size. Gamma irradiation had significant effects on tomato plants generated from dry seed and submitted to different levels of salinity. It is recommended a dose range of 100-200 Gy for mutation breeding purpose using the varieties tested. (author)

  18. Measuring radiation dose to patients undergoing fluoroscopically-guided interventions

    International Nuclear Information System (INIS)

    Lubis, L E; Badawy, M K

    2016-01-01

    The increasing prevalence and complexity of fluoroscopically guided interventions (FGI) raises concern regarding radiation dose to patients subjected to the procedure. Despite current evidence showing the risk to patients from the deterministic effects of radiation (e.g. skin burns), radiation induced injuries remain commonplace. This review aims to increase the awareness surrounding radiation dose measurement for patients undergoing FGI. A review of the literature was conducted alongside previous researches from the authors’ department. Studies pertaining to patient dose measurement, its formalism along with current advances and present challenges were reviewed. Current patient monitoring techniques (using available radiation dosimeters), as well as the inadequacy of accepting displayed dose as patient radiation dose is discussed. Furthermore, advances in real-time patient radiation dose estimation during FGI are considered. Patient dosimetry in FGI, particularly in real time, remains an ongoing challenge. The increasing occurrence and sophistication of these procedures calls for further advances in the field of patient radiation dose monitoring. Improved measuring techniques will aid clinicians in better predicting and managing radiation induced injury following FGI, thus improving patient care. (paper)

  19. Chemical properties of Aspergillus flavus-infected soybean seeds exposed to gamma-irradiation during storage

    International Nuclear Information System (INIS)

    Mahrous, S.R.

    2007-01-01

    The aim of the present study was to examine the chemical properties of Aspergillus flavus-infected soybean seeds exposed to different levels of gamma-irradiation; 0 1, 3 and 5 kGy, during storage. The results revealed that there was no effect of irradiation at different dose levels on moisture, protein, total lipids and amino acids content of the seeds for overall 60 days of storage under ambient temperature. At zero time, irradiation of A. flavus- infected-soybean seeds at 5.0 kGy caused a slight increase in peroxide value, no change in acid value, a slight decrease in saponification and iodine values in the crude oil extracted from the seeds. An increase in saturated fatty acids associated with a decrease in un-saturated fatty acids was also observed in the oil extracted from the seeds. Furthermore, at dose level 5 kGy the fungus growth was completely inhibited and there was no detection of aflatoxin B1 after 60 days of storage. It is concluded that gamma-irradiation of A. flavus-infected soybean seeds at dose level 5 kGY is sufficient to inhibit fungus growth and aflatoxin production over a storage period of 60 days without changes in major chemical properties of the seeds and the oil extracted from seeds

  20. Silicon application to the soil on soybean yield and seed physiological quality

    Directory of Open Access Journals (Sweden)

    Sandro de Oliveira

    2015-10-01

    Full Text Available Use of quality seeds, balanced plant nutrition and the adoption of adequate cultivation techniques are critical to the success of the soybean crop. Use of silicon (Si is a clean technology from an environmental point of view, which can confer several benefits to the plants as stimulate growth and plant production, improve tolerance of plants to attack by insects and diseases, reduce perspiration and increase the photosynthetic rate and protect against abiotic stresses. The goal was to evaluate the effect of soil Si application derived from rice husk ash on the agronomic characteristics, productivity and physiological quality of soybean cultivars seeds. The experiment was conducted in pots of 18 L filled with soil, under a randomized block design with four replications. The soybean cultivars were BMX Turbo RR and NA 5909 RR, grown under five doses of silicon (0, 1, 2, 3, and 4 t ha-1. Agronomic traits and seed yield were evaluated (total number of pods on branches, total number of seeds on the branches, the total number of pods on the main stem, total number of seeds on the main stem, total number of pods per plant, total number of seeds per plant, seed weight per plant and seed weight of 1000. Physiological seed quality was evaluated by germination and vigor tests (first count of germination, cold test, accelerated aging, shoot length and root. The soil application of silicon is beneficial for the soybean crop, improving the main agronomic characteristics (total number of pods on branches, total number of seeds in the branches, total number of pods per plant, weight of seeds per plant and increasing seed yield per plant in soybean cultivar BMX Turbo RR. The mass of a thousand seeds is positively influenced by the dose of 1.67 t ha-1 for the cultivar BMX Turbo RR and up to a dose of 2.32 t ha-1 for the cultivar NA 5909 RR. Cultivar BMX Turbo RR seed vigor is increased with the use of silicon in the soil.

  1. Effect of apricot seeds on renal structure of rabbits

    Directory of Open Access Journals (Sweden)

    Anna Kolesárová

    2017-01-01

    Full Text Available Amygdalin is the major cyanogenic glycoside present in apricot seeds and is degraded to cyanide by chewing or grinding. The animal data available did not provide a suitable basis for acute human health hazard. The apricot seeds are potentially useful in human nutrition and for treatment of several diseases especially cancer. The present study demonstrates the potential effect of short-term oral application of apricot seeds on renal structure of rabbit as a biological model. Meat line P91 Californian rabbits from the experimental farm of the Animal Production Research Centre Nitra (Slovak Republic were used in the experiments. The animals were randomly divided into the three groups (C-control, P1, P2 - experimental groups leading to 8 rabbits in each group. The control group received no apricot seeds while the experimental groups P1 and P2 received a daily dose 60 and 300 mg.kg-1 b.w. of crushed apricot seeds mixed with feed during 28 days, respectively. After 28 days all animals were slaughtered and kidney tissue was processed by standard histopathological techniques. Tissue sections were observed under an optical microscope with camera Olympus CX41 (Olympus, Japan at a magnification of 10 x 0.40. The basic morphometric criteria of the preparations were quantified using image program MeasurIT (Olympus, Japan. From each sample (n = 24 three histological sections with five different fields of view in each section were analysed and followed parameters were analysed: diameter of renal corpuscles (RC, diameter of glomeruli (G, diameter of tubules (T and the height of epithelial tubules (E. In our study, we observed a slight increase in the most frequent occurrence parenchyma dystrophy experimental animals. These changes were more pronounced in the experimental group (P2 rabbits received a daily dose of 300 mg.kg-1 of body weight of apricot seeds. Most often, we have found enlarged glomeruli filling the entire space of the capsule, and also glomerular

  2. The minimum measurable dose of the sensitive Harshaw TLDs

    International Nuclear Information System (INIS)

    Ben-Shachar, B.; German, U.; Naim, E.

    1991-01-01

    The TL-dose response was measured for the sensitive Harshaw manufactured phosphors (CaF 2 :Dy and CaF 2 :Tm), taking chips from the same batch and from different batches. The relative standard deviations were fitted to a semiempirical expression, from which the minimum measurable doses were derived and compared to the minimum measurable dose calculated by taking 3 times the standard deviation of unirradiated chips. The contribution of the individual calibration of each TLD chip was checked, as well

  3. Effect of low doses of gamma radiation on alfalfa (Lucerne) yield

    Energy Technology Data Exchange (ETDEWEB)

    Al-Odat, M; Khalifa, Kh [Atomic Energy Commission, Damascus (Syrian Arab Republic). Dept. of Radiation Agriculture

    1994-11-01

    Presowing seed irradiation has been reported frequently as a useful application of radiation in agriculture to stimulate growth and increase the yield of field and horticulture crops. Lucerne seeds of previous season (local variety) were irradiated by gamma rays Cs sup 1 sup 3 sup 7 source using doses of 5, 10, 15, 20, 30, and 40 Gy at dose rate of 9.2 Gy/min. Then were planted after 7 days from irradiation with unirradiated control in complete randomized block design and 5 replicates for three seasons (1986, 1987, 1988), the field experiment was carried out at ACSAD research station in Der-Ezzor. Also pot experiments were carried out to study the effect of low doses gamma irradiation on seed germination and growth of shoot and root systems of seedlings. The following observation were made on plants grown in the field:- fresh weight and dry weight of shoot system, - seed yield at the end of the experiment. The results show that there is a positive effect of seed irradiation on percentage of germination and root systems of seedling compared with the control. the highest increase in dry weight of shoot and root systems was at doses of 10 and 15 Gy. specially when sowing was 10 days after irradiation. Gamma irradiation doses of 10 and 15 Gy led to significant increases in fresh and dry weight at shoot system in the three seasons. The increases were 17.5% and 14.6% for the doses of 10 and 15 Gy respectively. A considerable increase in seed yield obtained at doses from 10 to 40 Gy, and the seed yield varied from 13.3% to 17.9% Compared with the control. (author). 20 refs., 18 tabs.

  4. Field measurement and interpretation of beta doses and dose rates

    International Nuclear Information System (INIS)

    Selby, J.M.; Swinth, K.L.; Hooker, C.D.; Kenoyer, J.L.

    1983-01-01

    A wide variety of portable survey instruments employing GM, ionization chamber and scintillation detectors exist for the measurement of gamma exposure rates. Often these same survey instruments are used for monitoring beta fields. This is done by making measurements with and without a removable shield which is intended to shield out the non-penetrating component (beta) of the radiation field. The difference does not correspond to an absorbed dose rate for the beta field due to a variety of factors. Among these factors are the dependence on beta energy, source-detector geometries, mixed fields and variable ambient conditions. Attempting to use such measurements directly can lead to errors as high as a factor of 100. In many instances correction factors have been derived, that if properly applied, can reduce these errors substantially. However, this requires some knowledge of the beta spectra, calibration techniques and source geometry. This paper discusses some aspects of the proper use of instruments for beta measurements including the application of appropriate correction factors. Ionization type instruments are commonly used to measure beta dose rates. Through design and calibration these instruments will give an accurate reading only for uniform irradiation of the detection volume. Often in the field it is not feasible to meet these conditions. Large area uniform distributions of activity are not generally encountered and it is not possible to use large source-to-detector distances due to beta particle absorption in air. An example of correction factors required for various point sources is presented when a cutie pie ionization chamber is employed. The instrument reading is multiplied by the appropriate correction factor to obtain the dose rate at the window. When a different detector is used or for other geometries, a different set of correction factors must be used

  5. 125I eye plaque dose distribution including penumbra characteristics.

    Science.gov (United States)

    de la Zerda, A; Chiu-Tsao, S T; Lin, J; Boulay, L L; Kanna, I; Kim, J H; Tsao, H S

    1996-03-01

    The two main purposes of this work are (1) to determine the penumbra characteristics for 125I eye plaque and the relative influence of the plaque and eye-air interface on the dose distribution, and (2) to initiate development of a treatment planning algorithm for clinical dose calculations. Dose was measured in a newly designed solid water eye phantom for an 125I (6711) seed at the center of a 20 mm COMS eye plaque using thermoluminescent dosimeter (TLD) "cubes" and "minichips" inside and outside the eye, in the longitudinal and transverse central planes. TLD cubes were used in most locations, except for short distances from the seed and in the penumbra region. In the presence of both the plaque and the eye-air interface, the dose along the central axis was found to be reduced by 10% at 1 cm and up to 20% at 2.5 cm, relative to the bulk homogeneous phantom case. In addition, the overall dose reduction was greater for larger off-axis coordinates at a given depth. The penumbra characteristics due to the lip collimation were quantified, particularly the dependence of penumbra center and width on depth. Only small differences were observed between the profiles in the transverse and longitudinal planes. In the bulk geometry (without the eye-air interface), the dose reduction due to the presence of the plaque alone was found to be 7% at a depth of 2.5 cm. The additional reduction of 13% observed, with the presence of eye-air interface (20% combined), can be attributed to the lack of backscattering from the air in front of the eye. The dose-reduction effect due to the anterior air interface alone became unnoticeable at a depth of 1.1 cm (1.5 cm from the eye-air interface). An analytic fit to measured data was developed for clinical dose calculations for a centrally loaded seed. The central axis values of the dose rates multiplied by distance squared, Dr2, were fitted with a double exponential function of depth. The off-axis profile of Dr2, at a given depth, was

  6. Student's music exposure: Full-day personal dose measurements.

    Science.gov (United States)

    Washnik, Nilesh Jeevandas; Phillips, Susan L; Teglas, Sandra

    2016-01-01

    Previous studies have shown that collegiate level music students are exposed to potentially hazardous sound levels. Compared to professional musicians, collegiate level music students typically do not perform as frequently, but they are exposed to intense sounds during practice and rehearsal sessions. The purpose of the study was to determine the full-day exposure dose including individual practice and ensemble rehearsals for collegiate student musicians. Sixty-seven college students of classical music were recruited representing 17 primary instruments. Of these students, 57 completed 2 days of noise dose measurements using Cirrus doseBadge programed according to the National Institute for Occupational Safety and Health criterion. Sound exposure was measured for 2 days from morning to evening, ranging from 7 to 9 h. Twenty-eight out of 57 (49%) student musicians exceeded a 100% daily noise dose on at least 1 day of the two measurement days. Eleven student musicians (19%) exceeded 100% daily noise dose on both days. Fourteen students exceeded 100% dose during large ensemble rehearsals and eight students exceeded 100% dose during individual practice sessions. Approximately, half of the student musicians exceeded 100% noise dose on a typical college schedule. This finding indicates that a large proportion of collegiate student musicians are at risk of developing noise-induced hearing loss due to hazardous sound levels. Considering the current finding, there is a need to conduct hearing conservation programs in all music schools, and to educate student musicians about the use and importance of hearing protection devices for their hearing.

  7. Thermoluminescence studies on plant seeds of different radiosensitivity

    International Nuclear Information System (INIS)

    Yamaguchi, Hikoyuki; Eguchi, Hoshio; Koizumi, Yoshinobu.

    1975-01-01

    The thermoluminescence was found when the pulverized powders from the whole seeds of six plant species or the hypocotyls from the seeds of five soybean varieties were irradiated at a liquid nitrogen temperature with gamma-rays. The spectra of luminescence emitted, the light peak temperature, the decaying after irradiation and the dose relationship of luminescence were determined. A high yield of the rapidly-decaying luminescence occurred in the more radiosensitive variety when irradiated with relatively lower doses. The very drastic decrease of the thermoluminescence was observed in the samples irradiated at room temperature prior to the exposure at 77 0 K. (auth.)

  8. The influence of radiation of different doses on biometrical indicators of cucumber

    International Nuclear Information System (INIS)

    Gasanov, S.P.; Guseynova, M.Z.; Gulieva, L.M.; Alieva, M.I.; Eminova, N.M.

    2013-01-01

    As it is known, pre-irradiation of plant seeds is usually applied to improve the productivity of crops. Irradiation of seeds at low doses usually does not cause adverse effects. However, irradiation of seeds with higher doses leads to complete loss of cell division ability. In many cases, the morphological change of the primary leaves, and the observed inhibition of the development to such an extent that the plants are deprived of fruiting abilities. The obtained data shows that with increasing of irradiation dose these parameters decrease, at high radiation doses clearly inhibits development of the fruit

  9. Nootropic activity of Celastrus paniculatus seed.

    Science.gov (United States)

    Bhanumathy, M; Harish, M S; Shivaprasad, H N; Sushma, G

    2010-03-01

    The effect of Celastrus paniculatus Willd. (Celastraceae) seed aqueous extract on learning and memory was studied using elevated plus maze and passive avoidance test (sodium nitrite induced amnesia rodent model). The aqueous seed extract was administered orally in two different doses to rats (350 and 1050 mg/kg) and to mice (500 and 1500 mg/kg). The results were compared to piracetam (100 mg/kg, p.o.) used as a standard drug. Chemical hypoxia was induced by subcutaneous administration of sodium nitrite (35 mg/kg), immediately after acquisition training. In elevated plus maze and sodium nitrite-induced amnesia model, Celastrus paniculatus extract has showed statistically significant improvement in memory process when compared to control. The estimation of acetylcholinesterase enzyme in rat brain supports the plus maze and passive avoidance test by reducing acetylcholinesterase activity which helps in memory performance. The study reveals that the aqueous extract of Celastrus paniculatus seed has dose-dependent cholinergic activity, thereby improving memory performance. The mechanism by which Celastrus paniculatus enhances cognition may be due to increased acetylcholine level in rat brain.

  10. Why high seed densities within buried mesh bags may overestimate depletion rates of soil seed banks

    NARCIS (Netherlands)

    Mourik, van T.A.; Stomph, T.J.; Murdoch, A.J.

    2005-01-01

    1. Estimates of seed bank depletion rates are essential for modelling and management of plant populations. The seed bag burial method is often used to measure seed mortality in the soil. However, the density of seeds within seed bags is higher than densities in natural seed banks, which may elevate

  11. The measurement of patient doses from diagnostic x-rays

    International Nuclear Information System (INIS)

    Morris, N.D.; Solomon, S.B.

    1980-06-01

    As part of the National Health and Medical Research Council survey to determine the genetic and mean bone-marrow doses to the Australian population from the medical, dental and chiropractic uses of radiation sources, doses to patients undergoing X-ray diagnostic procedures were evaluated. The doses were measured using capsules of LiF or CaF 2 :Dy thermoluminescent dosemeters (TLD). The evaluation of the TLD measurements is described and the mean values of the skin doses for patients undergoing various radiographic examinations in Australia in 1970 are presented

  12. Effect of low dose gamma irradiation on onion yield: Large scale application

    International Nuclear Information System (INIS)

    Al-Oudat, M.

    1993-01-01

    Large scale application of presowing gamma-irradiation of seeds, bulblets and bulbs of onion, performed in 1989, using the doses of 10 Gy for seeds and 1 Gy for bulblets and bulbs. The doses were chosen on the basis of previous experiments. Reliable increases in yield of seeds (19.3%), bulblets (18.9) and bulbs (31.4%) for red variety. and of 22.3% and 23.4% for seeds and bulbs of white variety were obtained. (author). 2 tabs

  13. Bystander Effects Induced by Continuous Low-Dose-Rate 125I Seeds Potentiate the Killing Action of Irradiation on Human Lung Cancer Cells In Vitro

    International Nuclear Information System (INIS)

    Chen, H.H.; Jia, R.F.; Yu, L.; Zhao, M.J.; Shao, C.L.; Cheng, W.Y.

    2008-01-01

    Purpose: To investigate bystander effects of low-dose-rate (LDR) 125 I seed irradiation on human lung cancer cells in vitro. Methods and Materials: A549 and NCI-H446 cell lines of differing radiosensitivity were directly exposed to LDR 125 I seeds irradiation for 2 or 4 Gy and then cocultured with nonirradiated cells for 24 hours. Induction of micronucleus (MN), γH2AX foci, and apoptosis were assayed. Results: After 2 and 4 Gy irradiation, micronucleus formation rate (MFR) and apoptotic rate of A549 and NCI-H446 cells were increased, and the MFR and apoptotic rate of NCI-H446 cells was 2.1-2.8 times higher than that of A549 cells. After coculturing nonirradiated bystander cells with 125 I seed irradiated cells for 24 hours, MFR and the mean number of γH2AX foci/cells of bystander A549 and NCI-H446 cells were similar and significantly higher than those of control (p 125 I seeds could induce bystander effects, which potentiate the killing action on tumor cells and compensate for the influence of nonuniform distribution of radiation dosage on therapeutic outcomes

  14. Jatropha Curcas Seed Oil Linn ( Euphor Biaceae ): Contraceptive ...

    African Journals Online (AJOL)

    It was obvious that J. curcas seed oil is a volatile oil. It was also observed that tragacanth formed more stable primary emulsions than acacia gum. It was concluded that Jatropha curcas seed oil has significant contraceptive activity and it could be formulated into stable oral emulsion at doses not exceeding 0.5g/kg. Nig.

  15. An investigation of radiosensitivity of selected stored seed and seed borne fungi

    International Nuclear Information System (INIS)

    Maity, Jyoti Prakash; Chatterjee, S.; Mishra, D.; Chakraborty, A.; Saha, A.; Santra, S.C.; Chanda, S.

    2004-01-01

    Spoilage of nutritional value of the grains by the microbes, especially those producing mycotoxins, is a worldwide economic problem. The decontamination method, using gamma ray or fast electrons, is receiving growing attention. The present investigation was designed to determine an appropriate dose-range of gamma radiation for the stored grains to reduce levels of pathogenic fungi with minimal loss in viability, food value and/or germinating potential of the selected seeds. Further the study also aimed at assessing response of specific fungus to gamma irradiation in isolated condition and when attached to seeds to discern host-specific interaction if any, of the concerned fungi

  16. Differential radiosensitivity of seeds, seedlings and callus cultures of Petunia inflata

    International Nuclear Information System (INIS)

    Bapat, V.A.; Rao, P.S.

    1976-01-01

    A comparative study of the effects of γ-irradiation on seeds, seedlings and callus cultures of Petunia inflata showed striking differences in radiosensitivity as reflected in differences in mean fresh and dry weights, seedling height and morphology. Seeds subjected to low doses (4-6 kR) of irradiation showed stimulation of seedling height. Direct exposure of seedlings to high doses (10 kR) of irradiation caused inhibition in their development. Callus cultures, however, were more radioresistant compared to seeds and seedlings. Tissues grown on either an irradiated nutrient medium or on a medium in which sucrose alone had been irradiated, showed a marked inhibition in their growth potential

  17. Investigation of coagulation activity of natural coagulants from seeds of different leguminose species

    Directory of Open Access Journals (Sweden)

    Šćiban Marina B.

    2005-01-01

    Full Text Available The ability of seeds of plants: Phaseolus vulgaris, Robinia pseudoacacia Ceratonia siliqua and Amorpha fruticosa, to act as natural coagulants was tested using synthetic turbid water. This water was prepared by adding kaolin into tap water, just before the test. Active components were extracted from ground seeds with distilled water. The coagulation ability of this extract was assessed by the use of standard jar test measurements in water with various initial turbidity. Investigation of these natural coagulants was confirmed their positive coagulation activity. Of all plants that have been examined, the seed extract from Ceratonia siliqua appeared to be one of the most effective coagulants for water treatment. A dose of 20 mg/l of this coagulant resulted in 100% coagulation activity for clarification of water with 17.5 NTU initial turbidity.

  18. Online radiation dose measurement system for ATLAS experiment

    International Nuclear Information System (INIS)

    Mandic, I.; Cindro, V.; Dolenc, I.; Gorisek, A.; Kramberger, G.; Mikuz, M.; Bronner, J.; Hartet, J.; Franz, S.

    2009-01-01

    In experiments at Large Hadron Collider, detectors and electronics will be exposed to high fluxes of photons, charged particles and neutrons. Damage caused by the radiation will influence performance of detectors. It will therefore be important to continuously monitor the radiation dose in order to follow the level of degradation of detectors and electronics and to correctly predict future radiation damage. A system for online radiation monitoring using semiconductor radiation sensors at large number of locations has been installed in the ATLAS experiment. Ionizing dose in SiO 2 will be measured with RadFETs, displacement damage in silicon in units of 1-MeV(Si) equivalent neutron fluence with p-i-n diodes. At 14 monitoring locations where highest radiation levels are expected the fluence of thermal neutrons will be measured from current gain degradation in dedicated bipolar transistors. The design of the system and tests of its performance in mixed radiation field is described in this paper. First results from this test campaign confirm that doses can be measured with sufficient sensitivity (mGy for total ionizing dose measurements, 10 9 n/cm 2 for NIEL (non-ionizing energy loss) measurements, 10 12 n/cm 2 for thermal neutrons) and accuracy (about 20%) for usage in the ATLAS detector

  19. Dosimetry Modeling for Focal Low-Dose-Rate Prostate Brachytherapy

    Energy Technology Data Exchange (ETDEWEB)

    Al-Qaisieh, Bashar [Leeds Cancer Centre, Leeds Teaching Hospitals NHS Trust, Leeds (United Kingdom); Mason, Josh, E-mail: joshua.mason@nhs.net [Leeds Cancer Centre, Leeds Teaching Hospitals NHS Trust, Leeds (United Kingdom); Bownes, Peter; Henry, Ann [Leeds Cancer Centre, Leeds Teaching Hospitals NHS Trust, Leeds (United Kingdom); Dickinson, Louise [Division of Surgery and Interventional Science, University College London, London (United Kingdom); Department of Radiology, Northwick Park Hospital, London North West NHS Trust, London (United Kingdom); Ahmed, Hashim U. [Division of Surgery and Interventional Science, University College London, London (United Kingdom); University College London Hospital, London (United Kingdom); Emberton, Mark [University College London Hospital, London (United Kingdom); Langley, Stephen [St Luke' s Cancer Centre, Guildford (United Kingdom)

    2015-07-15

    Purpose: Focal brachytherapy targeted to an individual lesion(s) within the prostate may reduce side effects experienced with whole-gland brachytherapy. The outcomes of a consensus meeting on focal prostate brachytherapy were used to investigate optimal dosimetry of focal low-dose-rate (LDR) prostate brachytherapy targeted using multiparametric magnetic resonance imaging (mp-MRI) and transperineal template prostate mapping (TPM) biopsy, including the effects of random and systematic seed displacements and interseed attenuation (ISA). Methods and Materials: Nine patients were selected according to clinical characteristics and concordance of TPM and mp-MRI. Retrospectively, 3 treatment plans were analyzed for each case: whole-gland (WG), hemi-gland (hemi), and ultra-focal (UF) plans, with 145-Gy prescription dose and identical dose constraints for each plan. Plan robustness to seed displacement and ISA were assessed using Monte Carlo simulations. Results: WG plans used a mean 28 needles and 81 seeds, hemi plans used 17 needles and 56 seeds, and UF plans used 12 needles and 25 seeds. Mean D90 (minimum dose received by 90% of the target) and V100 (percentage of the target that receives 100% dose) values were 181.3 Gy and 99.8% for the prostate in WG plans, 195.7 Gy and 97.8% for the hemi-prostate in hemi plans, and 218.3 Gy and 99.8% for the focal target in UF plans. Mean urethra D10 was 205.9 Gy, 191.4 Gy, and 92.4 Gy in WG, hemi, and UF plans, respectively. Mean rectum D2 cm{sup 3} was 107.5 Gy, 77.0 Gy, and 42.7 Gy in WG, hemi, and UF plans, respectively. Focal plans were more sensitive to seed displacement errors: random shifts with a standard deviation of 4 mm reduced mean target D90 by 14.0%, 20.5%, and 32.0% for WG, hemi, and UF plans, respectively. ISA has a similar impact on dose-volume histogram parameters for all plan types. Conclusions: Treatment planning for focal LDR brachytherapy is feasible. Dose constraints are easily met with a notable

  20. Influence of breast composition and interseed attenuation in dose calculations for post-implant assessment of permanent breast 103Pd seed implant

    International Nuclear Information System (INIS)

    Afsharpour, Hossein; Beaulieu, Luc; Pignol, Jean-Philippe; Keller, Brian; Carrier, Jean-Francois; Reniers, Brigitte; Verhaegen, Frank

    2010-01-01

    The impact of tissue heterogeneity and interseed attenuation is studied in post-implant evaluation of five clinical permanent breast 103 Pd seed implants using the Monte Carlo (MC) dose calculation method. Dose metrics for the target (PTV) as well as an organ at risk (skin) are used to visualize the differences between a TG43-like MC method and more accurate MC methods capable of considering the breast tissue heterogeneity as well as the interseed attenuation. PTV dose is reduced when using a breast tissue model instead of water in MC calculations while the dose to the skin is increased. Furthermore, we investigate the effect of varying the glandular/adipose proportion of the breast tissue on dose distributions. The dose to the PTV (skin) decreases (increases) with the increasing adipose proportion inside the breast. In a complete geometry and compared to a TG43-like situation, the average PTV D 90 reduction varies from 3.9% in a glandular breast to 35.5% when the breast consists entirely of adipose. The skin D 10 increases by 28.2% in an entirely adipose breast. The results of this work show the importance of an accurate and patient-dependent breast tissue model to be used in the dosimetry for this kind of low energy implant.

  1. Radiosensitivity in seeds of Coix lachryma-jobi TOURN

    Energy Technology Data Exchange (ETDEWEB)

    Gabrielli, A C [Universidade Estadual de Campinas (Brazil). Inst. de Biologia; Medina Filho, H P [Instituto Agronomico de Campinas (Brazil)

    1979-04-01

    Radiosensitivity in seeds of Coix lachryma-jobi Tourn. Seeds of Coix lachryma-jobi Tourn., containing 9% humidity were irradiated with 0 to 70 Krad doses of gama-radiation from a /sup 60/Co source. The zero-time was set to be the time of sowing. At high doses of radiation, germination after 15 days was little affected, but after 21 days survival rate decreased. Our results show that the LD/sub 50/ is about 60 Krad and the GR/sub 50/ is approximately 30 Krad. The morphological alterations which were observed in some plants, as well as the effects of gama-radiation on growth inhibition and survival rate of the seedlings, suggest that doses between 30 and 50 Krad could be useful to obtain genetic variability in adapted cultivars of this species.

  2. Grape Seed Oil Extract Protects Against Radiation-Induced Oxidative Damage in Rats Eyes

    International Nuclear Information System (INIS)

    Naguib, N.I.

    2011-01-01

    The present study was carried out to investigate the beneficial effects of grape seed oil on radiation-induced oxidative stress in the irradiated rat eyes. The rats were divided into three groups; control group that received distilled water, irradiated group (R) that exposed to gamma radiation as a single dose of 6.4 Gy and irradiated + grape seed oil group (R+GSO) that administered grape seed oil for seven consecutive days then exposed to the same single gamma radiation dose followed by grape seed oil for seven additional days. Histopathological results revealed protective effect of grape seed oil on the eye tissues of rat. The results lead to the conclusion that administration of GSO prior to radiation exposure may be a promising attempt in attenuating the extent of oxidative damage accompanying radiotherapy

  3. Dose optimization in simulated permanent interstitial implant of prostate brachytherapy

    International Nuclear Information System (INIS)

    Faria, Fernando Pereira de

    2006-01-01

    Any treatment of cancer that uses some modality of radiotherapy is planned before being executed. In general the goal in radiotherapy is to irradiate the target to be treated minimizing the incidence of radiation in healthy surrounding tissues. The planning differ among themselves according to the modality of radiotherapy, the type of cancer and where it is located. This work approaches the problem of dose optimization for the planning of prostate cancer treatment through the modality of low dose-rate brachytherapy with Iodine 125 or Palladium 103 seeds. An algorithm for dose calculation and optimization was constructed to find the seeds configuration that better fits the relevant clinical criteria such as as the tolerated dose by the urethra and rectum and the desired dose for prostate. The algorithm automatically finds this configuration from the prostate geometry established in two or three dimensions by using images of ultrasound, magnetic resonance or tomography and from the establishment of minimum restrictions to the positions of the seeds in the prostate and needles in a template. Six patterns of seeds distribution based on clinical criteria were suggested and tested in this work. Each one of these patterns generated a space of possible seeds configurations for the prostate tested by the dose calculation and optimization algorithm. The configurations that satisfied the clinical criteria were submitted to a test according to an optimization function suggested in this work. The configuration that produced maximum value for this function was considered the optimized one. (author)

  4. Effect of low gamma ray doses on sugar beet

    International Nuclear Information System (INIS)

    Al-Oudat, M.

    1993-01-01

    We studied the effect of presowing irradiation simulation on sugar beet seeds in two regions (Deir Elzour and Damascus) and for three successive cropping seasons (1986-1989). Those seeds were irradiated with gamma radiation doses varying from 0.005 to 0.050 kGy in the first region, and from 0.005 to 0.025 kGy in the second region. Results showed that doses varying from 0.005 to 0.05 kGy in Deir Elzour gave a mean yield increase varying from 17.4% to 22.6%. However, doses varying from 0.005 to 0.025 in Damascus gave an increase of the same parameter between 19.5% and 23.8%. The best results for pure sugar yield increase obtained for a dose of 0.015 kGy (27.1% in Deir Elzour and 31.9% in Damascus). Yields on the farm level obtained from presowing irradiated seeds showed an increase in sugar beets when using 0.015 kGy gamma radiation dose. (author)

  5. Influence of pre-sowing irradiation of soya seeds with low doses of gamma rays on the yields of grain and on the content of crude protein in the grain

    International Nuclear Information System (INIS)

    Nikolov, Ch.V.

    1985-01-01

    Pre-sowing irradiation of air-dry soya seeds of the Hodson variety, calibrated in size and humidity (12%), with gamma rays in the range of relatively low intensities of irradiation of 0.27 to 5 Gy/min and doses of 10 to 20 Gy increases both the yield of grain and the content of crude protein in the grain in relation to the absolute dry matter. The dependence of radiostimulation effect on the factors of the environment cannot be reason for neglecting it as a posssible reserve for increasing the yield of grain from soya and the content of crude protein in the grain. Possible results are exspected from production experiments with pre-sowing irradiation of seeds of Hodson variety using gamma rays in the range of the above intensities and doses

  6. First symposium seed implant 125I and high rate of prostate

    International Nuclear Information System (INIS)

    2012-01-01

    The First symposium seed implant 125 I and high rate of prostate, was organized by the Marie Curie Foundation, between the 12 to april 2012, in the Cordoba city of Argentina. In this event were presented several documents in different topics: patients selection for impacts of 125 I seeds; high doses radiation in radiotherapy; brachytherapy for prostate cancer; prostate implant technique with 125 I seeds; implant dosimetric aspects; radioprotection of 125 I seeds.

  7. Biological effects of low energy nitrogen ion implantation on Jatropha curcas L. seed germination

    Science.gov (United States)

    Xu, Gang; Wang, Xiao-teng; Gan, Cai-ling; Fang, Yan-qiong; Zhang, Meng

    2012-09-01

    To explore the biological effects of nitrogen ion beam implantation on dry Jatropha curcas seed, a beam of N+ with energy of 25 keV was applied to treat the dry seed at six different doses. N+ beam implantation greatly decreased germination rate and seedling survival rate. The doses within the range of 12 × 1016 to 15 × 1016 ions cm-2 severely damaged the seeds: total antioxidant capacity (TAC), germination rate, seedling survival rate, reduced ascorbate acid (HAsA) and reduced glutathione (GSH) contents, and most of the tested antioxidases activity (i.e. catalase (CAT), ascorbate peroxidase (APX) and superoxide dismutase (SOD)) reached their lowest levels. At a dose of 18 × 1016 ion cm-2, biological repair took place: moderate increases were found in TAC, germination rate, seedling survival rate, HAsA and GSH contents, and some antioxidant enzyme activities (i.e. CAT, APX, SOD and GPX). The dose of 18 × 1016 ions cm-2 may be the optimum dose for use in dry J. curcas seed mutation breeding. CAT, HAsA and GSH contributed to the increase of TAC, but CAT was the most important. POD performed its important role as seed was severely damaged. The main role of the HAsA-GSH cycle appeared to be for regeneration of HAsA.

  8. Effects if 60Co γ rays radiation on seed vigor and young seedling growth of phyllostachys edulis

    International Nuclear Information System (INIS)

    Cai Chunju; Gao Jian; Mu Shaohua

    2007-01-01

    The dry seeds of Phyllostachys edulis were irradiated by different doses of 60 Co γ rays, the effects of the radiation on seed vigor and seedling growth characters were investigated by four testing methods, i.e. germination testing indoor, electrical conductivity, TTC vigor testing and growth classification of saddling. Results showed that the germination process and germination rate could be accelerated by doses of 60 Co γ rays (≤100 Gy), and higher doses of 60 Co γ rays (>100 Gy) could obviously inhibit the germination process and reduce seed vigor, while induce seed embryo broken, cell division, growth restrained, the height of young seedling and length of root decreasing. The inhibition effects were significantly increased with radiation dose increase. The optimal range of radiation dose for radiation breeding of Phyllostachys edulis dry seeds was 100 to 175 Gy. Linear relationships were existed in electrical conductivity after dipping in water for 24h in germination rate (G), germination index (GI), vigor index (VI), height of seedlings and length of root. EC after 24h and height of seedlings were chosen to test the change of seeds vigor and the effect of the radiation of 60 Co γ rays on Phyllostachys edulis. (authors)

  9. Measurement of dosimetric parameters and dose verification in stereotactic radiosurgery (SRS)

    International Nuclear Information System (INIS)

    Reduan Abdullah; Nik Ruzman Nik Idris; Ahmad Lutfi Yusof; Mazurawati Mohamed

    2013-01-01

    Full-text: The purpose of this study was to measure the dosimetric parameters for small photon beams to be used as input data treatment planning computer system (TPS) and to verify dose calculated by TPS in Stereotactic Radiosurgery (SRS) procedure. The beam data required were Percentage Depth Dose (PDD), Off-axis Ratio (OAR), and Scatter Factor of Relative Output Factor. Small beams of 5 mm to 45 mm diameter circular cone collimators used in SRS were utilized for beam data measurements measured using pinpoint 3D ionization chamber (0.016 cc). For second part of this study, we reported the important quality assurance (QA) procedures before SRS treatment that influenced the dose delivery. These QA procedures consist of measurements on the accuracy in target localization and room laser alignment. The dose calculated to be delivered for treatment was verified using pinpoint 3D ionization chamber and TLD 100H. The mean deviation of measured dose using TLD 100H compared to calculated dose was 3.37 %. Beside that, pinpoint ionization 3D chamber give more accurate results of dose compared to TLD 100H. The measured dose using pinpoint 3D ionization chamber are good agreement with calculated dose by TPS with deviation of 2.17 %. The results are acceptable such as recommended by International Commission on Radiation Units and Measurements (ICRU) Report No. 50 (1993) that dose delivered to the target volume must be within ±5 % error. (author)

  10. Measuring of filtration efficiency of nonwoven textiles in volume from scattered light by seeding particles

    Directory of Open Access Journals (Sweden)

    Sidlof P.

    2013-04-01

    Full Text Available This paper deals with the method which calculates a filtration efficiency of nonwoven textiles from scattered light intensity by seeding particles. Thefiltration efficiency is commonly measured by particle counters. Samples of liquid or gas are taken during a test in front of and behind a filtration material. The concentration of particles is measured and the filtration efficiency is calculated. The filtration efficiency does not have to be uniform in itswhole surface. The uniformity of filtration is another indicator of a quality of filtration materials. Measurements described in this article were performed on a water filtration setup which enables optical access to the place where the filtration material is mounted. Pictures of illuminated seeding particles are made by a laser sheet and a camera. Visualisation of the filtration process enables measuring of the efficiency of separation versus time and also versus two-dimensional position in case of use of a traverse mechanism. The filtration textiles were tested by 1 μm seeding particles. Mean value of light intensity and number of bright pixels in evaluative areas during image analysis were obtained. On the basis of these data, the filtration efficiency iscalculated. The best image analysis method was chosen.

  11. Seed-migration detector for embolized seeds to the lung in the context of permanent iodine-125 prostate brachytherapy

    International Nuclear Information System (INIS)

    Morrier, J.; Chretien, M.; Beaulieu, L.

    2008-01-01

    Full text: Purpose: To evaluate the efficacy of a seed-migration detector for embolized seeds to the lung in the context of permanent iodine-125 prostate brachytherapy and to compare its performance to fluoroscopy and to the postoperative chest radiographs generally recommended. Materials and Methods: A low energy gamma scintillation survey meter, Victoreen Model 425-110 was used together with a Victoreen count rate meter (model 190). It was converted to a seed-migration detector by adding a shield on the scintillation probe detection window, following the method proposed by Chen and Blair in 2003 [Med Phys 2003;30:785790]. The detector response to three seeds activities of iodine 125 (0.42, 0.22 and 0.06 mCi) was measured for different source-to-detector distances in air and in water. The detector was used to perform a chest evaluation on 579 patients at their first postoperative visit, for a total of 31 826 seeds. When the detector showed activity around a patients chest, it was confirmed by taking an antero-posterior chest radiograph and by looking at the region with fluoroscopy. Results: 79 patients (13.6%) present at least one embolized seed in the chest area. This account for 94 of the 31 826 seeds, that is a 0.30% seed migration rate. Sixty-eight, seven and four patients had respectively a single, two and three seeds embolization. In three cases, a seed had migrated in the kidney, which was confirmed with a CT scan. Of the 94 seeds, 67 (71%) were visible under fluoroscopy and 55 (59%) appeared on the chest radiograph. Rapid movement of the seeds in the chest area, due to breathing or to a location close to the heart or the diaphragm, makes nine seeds to be visible with fluoroscopy but not on the radiograph. This also explains why twenty-seven seeds were not visible with fluoroscopy neither with radiograph. In comparison to the seed-migration detector, detection based on fluoroscopy would have led to twenty-seven false-negative detections while the radiograph

  12. Experimental measurements of spatial dose distributions in radiosurgery treatments

    International Nuclear Information System (INIS)

    Avila-Rodriguez, M. A.; Rodriguez-Villafuerte, M.; Diaz-Perches, R.; Perez-Pastenes, M. A.

    2001-01-01

    The measurement of stereotactic radiosurgery dose distributions requires an integrating, high-resolution dosimeter capable of providing a spatial map of absorbed dose. This paper describes the use of a commercial radiochromic dye film (GafChromic MD-55-2) to measure radiosurgery dose distributions with 6 MV X-rays in a head phantom. The response of the MD-55-2 was evaluated by digitizing and analyzing the films with conventional computer systems. Radiosurgery dose distributions were measured using the radiochromic film in a spherical acrylic phantom of 16 cm diameter undergoing a typical SRS treatment as a patient, and were compared with dose distributions provided by the treatment planning system. The comparison lead to mean radial differences of ±0.6 mm, ±0.9 mm, ±1.3 mm, ±1.9 mm, and ±2.8 mm, for the 80, 60, 50, 40, and 30% isodose curves, respectively. It is concluded that the radiochromic film is a convenient and useful tool for radiosurgery treatment planning validation

  13. Standardization of high-dose measurement of electron and gamma ray absorbed doses and dose rates

    International Nuclear Information System (INIS)

    McLaughlin, W.L.

    1985-01-01

    Intense electron beams and gamma radiation fields are used for sterilizing medical devices, treating municipal wastes, processing industrial goods, controlling parasites and pathogens, and extending the shelf-life of foods. Quality control of such radiation processes depends largely on maintaining measurement quality assurance through sound dosimetry procedures in the research leading to each process, in the commissioning of that process, and in the routine dose monitoring practices. This affords documentation as to whether satisfactory dose uniformity is maintained throughout the product and throughout the process. Therefore, dosimetry at high doses and dose rates must in many radiation processes be standardized carefully, so that 'dosimetry release' of a product is verified. This standardization is initiated through preliminary dosimetry intercomparison studies such as those sponsored recently by the IAEA. This is followed by establishing periodic exercises in traceability to national or international standards of absorbed dose and dose rate. Traceability is achieved by careful selection of dosimetry methods and proven reference dosimeters capable of giving sufficiently accurate and precise 'transfer' dose assessments: (1) they must be calibrated or have well-established radiation-yield indices; (2) their radiation response characteristics must be reproducible and cover the dose range of interest; (3) they must withstand the rigours of back-and-forth mailing between a central standardizing laboratory and radiation processing facilities, without excessive errors arising due to instabilities, dosimeter batch non-uniformities, and environmental and handling stresses. (author)

  14. Remote control and data processing for measurement of radiation dose

    International Nuclear Information System (INIS)

    Zhou Yu; Luo Yisheng; Guo Yong; Ji Gang; Wang Xinggong; Zhang Hong; Zhang Wenzhong

    2004-01-01

    Objective: To protect the workers from the reactor radiation and to improve the accuracy and efficiency of neutron dose measurement. Methods: With the application of remote control technology, a remote control and automatic measurement system for radiation dose measurement(especially for neutron dose) was set up. A Model 6517A electrometer was operated all automatically over RS-232 serial interface using SCPI commands with a computer. Results: The workers could stay far from the reactor and be able to control the portable computer in site though internet or LAN and then to control the 6517A electrometer to implement the dose measurement. After the measurement, the data were transferred to the remote computer near the workers and shared by many experts at the first time through the net. Conclusion: This is the first time that the remote control technology is applied in radiation dose measurement, which has so far been considered can only be performed at a near place. This new system can meet the need of neutron radiobiology researches as well as of the safety and health of the workers. (author)

  15. Measurement and comparison of skin dose using OneDose MOSFET and Mobile MOSFET for patients with acute lymphoblastic leukemia.

    Science.gov (United States)

    Mattar, Essam H; Hammad, Lina F; Al-Mohammed, Huda I

    2011-07-01

    Total body irradiation is a protocol used to treat acute lymphoblastic leukemia in patients prior to bone marrow transplant. It is involved in the treatment of the whole body using a large radiation field with extended source-skin distance. Therefore measuring and monitoring the skin dose during the treatment is important. Two kinds of metal oxide semiconductor field effect transistor (OneDose MOSFET and mobile MOSEFT) dosimeter are used during the treatment delivery to measure the skin dose to specific points and compare it with the target prescribed dose. The objective of this study was to compare the variation of skin dose in patients with acute lymphatic leukemia (ALL) treated with total body irradiation (TBI) using OneDose MOSFET detectors and Mobile MOSFET, and then compare both results with the target prescribed dose. The measurements involved 32 patient's (16 males, 16 females), aged between 14-30 years, with an average age of 22.41 years. One-Dose MOSFET and Mobile MOSFET dosimetry were performed at 10 different anatomical sites on every patient. The results showed there was no variation between skin dose measured with OneDose MOSFET and Mobile MOSFET in all patients. Furthermore, the results showed for every anatomical site selected there was no significant difference in the dose delivered using either OneDose MOSFET detector or Mobile MOSFET as compared to the prescribed dose. The study concludes that One-Dose MOSFET detectors and Mobile MOSFET both give a direct read-out immediately after the treatment; therefore both detectors are suitable options when measuring skin dose for total body irradiation treatment.

  16. In situ measurements of dose rates from terrestrial gamma rays

    International Nuclear Information System (INIS)

    Horng, M.C.; Jiang, S.H.

    2002-01-01

    A portable, high purity germanium (HPGe) detector was employed for the performance of in situ measurements of radionuclide activity concentrations in the ground in Taiwan, at altitudes ranging from sea level to 3900 m. The absolute peak efficiency of the HPGe detector for a gamma-ray source uniformly distributed in the semi-infinite ground was determined using a semi-empirical method. The gamma-ray dose rates from terrestrial radionuclides were calculated from the measured activity levels using recently published dose rate conversion factors. The absorbed dose rate in air due to cosmic rays was derived by subtracting the terrestrial gamma-ray dose rate from the overall absorbed dose rate in air measured using a high-pressure ionization chamber. The cosmic-ray dose rate calculated as a function of altitude, was found to be in good agreement with the data reported by UNSCEAR. (orig.)

  17. BeO-OSL detectors for dose measurements in cell cultures

    International Nuclear Information System (INIS)

    Andreeff, M.; Freudenberg, R.; Kotzerke, J.; Sommer, D.; Reichelt, U.; Henniger, J.

    2009-01-01

    Aim: The absorbed dose is an important parameter in experiments involving irradiation of cells in vitro with unsealed radionuclides. Typically, this is estimated with a model calculation, although the results thus obtained cannot be verified. Generally used real-time measurement methods are not applicable in this setting. A new detector material with in vitro suitability is the subject of this work. Methods: Optically-stimulated luminescence (OSL) dosimeters based on beryllium oxide (BeO) were used for dose measurement in cell cultures exposed to unsealed radionuclides. Their qualitative properties (e. g. energy-dependent count rate sensitivity, fading, contamination by radioactive liquids) were determined and compared to the results of a Monte Carlo simulation (using AMOS software). OSL dosimeters were tested in common cell culture setups with a known geometry. Results: Dose reproducibility of the OSL dosimeters was ± 1.5%. Fading at room temperature was 0.07% per day. Dose loss (optically-stimulated deletion) under ambient lighting conditions was 0.5% per minute. The Monte Carlo simulation for the relative sensitivity at different beta energies provided corresponding results to those obtained with the OSL dosimeters. Dose profile measurements using a 6 well plate and 14 ml PP tube showed that the geometry of the cell culture vessel has a marked influence on dose distribution with 188 Re. Conclusion: A new dosimeter system was calibrated with β-emitters of different energy. It turned out as suitable for measuring dose in liquids. The dose profile measurements obtained are suitably precise to be used as a check against theoretical dose calculations. (orig.)

  18. The Australian Commonwealth standard of measurement for absorbed radiation dose

    International Nuclear Information System (INIS)

    Sherlock, S.L.

    1990-06-01

    This report documents the absorbed dose standard for photon beams in the range from 1 to 25 MeV. Measurements of absorbed dose in graphite irradiated by a beam of cobalt-60 gamma rays from an Atomic Energy of Canada Limited (AECL) E1 Dorado 6 teletherapy unit are reported. The measurements were performed using a graphite calorimeter, which is the primary standard for absorbed dose. The measurements are used to calibrate a working standard ion chamber in terms of absorbed dose in graphite. Details of the methods, results and correction factors applied are given in Appendices. 13 refs., 6 tabs., 6 figs

  19. Effects of storage and soaking on wheat seeds exposed to gamma rays

    International Nuclear Information System (INIS)

    Ajayi, N.O.

    1975-07-01

    Wheat seeds, variety Starke II, of water content 11,5 per cent of dry weight, irradiated with 60 Co gamma rays over a wide range of absorbed doses were sowed in wet sand. When analysed after eight days, seedling growth was found to have decreased with increasing dose, very rapidly within the first 40 krad and more slowly thereafter until that dose, 500 krad, which made the shoot and the root fail to develop. Storage over three weeks was found to produce greater reduction in the seelding growth at doses below 40 krad, and lowering of the dose at which the seedling failed to develop from about 500 krad to 300 krad. Soaking the irradiated seeds immediately after irradiation for one hour before planting was found to improve the seedling growth in the low dose region compared to when seeds were immediately sowed. It is suggested that the water absorbed during soaking permits the free radicals to recombine and DNA-damage to be repaired. It is thought that radiation seriously affects cellular multiplication and the production of growth promoting homones of the embryo. On the other hand elongation of surviving, presumably non-mitotic cells, is apparently taking place even at high doses, in fact up to 500 krad. (author)

  20. Computerized assessment of the measurement of individual doses

    International Nuclear Information System (INIS)

    Kiibus, A.

    1981-06-01

    The department for the measurements of individual doses makes regular dose controls by means of film badges for approximately 14000 individuals. The operation is facilitated by a Honeywell Bull Mini 6 Mod 43 computer. The computer language is COBOL applied to registering of in-data such as delivery of badges, film development, calibration, invoices, recording of individual doses and customers. The print-out consists of customers, badge codes, dosimeter lists, development specifications, dose statements, addresses, bills, dose statistics and the register of individuals. As a consequence of charges the activity is financially self-supporting. (G.B.)

  1. Primary experiment aimed at selecting the suitable dose to mutation induction in two soybean cultivars

    International Nuclear Information System (INIS)

    Nabulsi, I.; Mir Ali, N

    1991-07-01

    Seeds from two soybean [Glycine Max L. (Merrill)] cultivars K-25 and K-38 were irradiated with the following doses of gamma rays: 100, 150, 200, 250, 300, 350, 400 and 500 Gy. The dose rate was 9.25 Gy/minute. A week after irradiation 25 seeds were sown from each variety in pots (26.5 x 26.5 cm) with 4 replicates in a randomized complete block design under greenhouse conditions. The distance between the cotyledon and the first leaf was measured 4 weeks after sowing and the results showed stimualtion effect in the 100 and 150 Gy doses in comparison to the control whereas in the higher doses, a gradual reduction was realized in addition to the appearance of the necrotic spots on the leaves which was increased in percentages along with the dose. The results indicated that doses between 100 and 200 Gy achieved the highest rate of mutations with minimal rate of lethality hence achieving the aim of this preliminary experiment. (author). 5 refs., 2 tabs., 2 figs

  2. Biological effects of low energy nitrogen ion implantation on Jatropha curcas L. seed germination

    Energy Technology Data Exchange (ETDEWEB)

    Xu Gang, E-mail: xg335300@yahoo.com.cn [Center for Research and Development of Fine Chemicals, Guizhou University, Guiyang 550025 (China); Institute of Entomology, Guizhou University, Guiyang 550025 (China); Wang Xiaoteng [Department of Agricultural Resources and Environment, College of Agricultural, Guizhou University, Guiyang 550025 (China); Gan Cailing; Fang Yanqiong; Zhang Meng [College of Life Sciences, Guizhou University, Guiyang 550025 (China)

    2012-09-15

    Highlights: Black-Right-Pointing-Pointer We analyzed biological effects of N{sup +} implantation on dry Jatropha curcas seed. Black-Right-Pointing-Pointer N{sup +} implantation greatly decreased seedling survival rate. Black-Right-Pointing-Pointer At doses beyond 15 Multiplication-Sign 10{sup 16} ion cm{sup -2}, biological repair took place. Black-Right-Pointing-Pointer CAT was essential for H{sub 2}O{sub 2} removal. POD mainly functioned as seed was severely hurt. Black-Right-Pointing-Pointer HAsA-GSH cycle mainly contributed to the regeneration of HAsA. - Abstract: To explore the biological effects of nitrogen ion beam implantation on dry Jatropha curcas seed, a beam of N{sup +} with energy of 25 keV was applied to treat the dry seed at six different doses. N{sup +} beam implantation greatly decreased germination rate and seedling survival rate. The doses within the range of 12 Multiplication-Sign 10{sup 16} to 15 Multiplication-Sign 10{sup 16} ions cm{sup -2} severely damaged the seeds: total antioxidant capacity (TAC), germination rate, seedling survival rate, reduced ascorbate acid (HAsA) and reduced glutathione (GSH) contents, and most of the tested antioxidases activity (i.e. catalase (CAT), ascorbate peroxidase (APX) and superoxide dismutase (SOD)) reached their lowest levels. At a dose of 18 Multiplication-Sign 10{sup 16} ion cm{sup -2}, biological repair took place: moderate increases were found in TAC, germination rate, seedling survival rate, HAsA and GSH contents, and some antioxidant enzyme activities (i.e. CAT, APX, SOD and GPX). The dose of 18 Multiplication-Sign 10{sup 16} ions cm{sup -2} may be the optimum dose for use in dry J. curcas seed mutation breeding. CAT, HAsA and GSH contributed to the increase of TAC, but CAT was the most important. POD performed its important role as seed was severely damaged. The main role of the HAsA-GSH cycle appeared to be for regeneration of HAsA.

  3. Microbial quality evaluation and effective decontamination of nutraceutically valued lotus seeds by electron beams and gamma irradiation

    International Nuclear Information System (INIS)

    Bhat, Rajeev; Sridhar, K.R.; Karim, A.A.

    2010-01-01

    Lotus seeds are nutraceutically valued natural plant produce, which succumbs to microbial contamination, predominantly to toxigenic moulds. Results of the present study revealed seed coat portion to harbor higher proportion of microbial load, particularly fungi than cotyledon portion. Among the mycotoxins analyzed, aflatoxins (B 1 , B 2 , G 1 and G 2 ) were below detectable limits, while the seeds were devoid of Ochratoxin-A (OTA). Application of different doses of electron beam and gamma irradiation (0, 2.5, 5, 7.5, 10, 15 and 30 kGy) for decontamination purpose revealed significant dose-dependent decrease in the fungal contaminants (P<0.05). However, the contaminant yeasts could survive up to 10 kGy dose, which could be completely eliminated at 15 kGy. From the results obtained, a dose range between 10 and 15 kGy is recommended for complete decontamination, as these doses have also been shown earlier to have minimal effects on nutritional and functional properties of lotus seeds.

  4. Analytical evaluation of dose measurement of critical accident at SILENE (Contract research)

    CERN Document Server

    Nakamura, T; Tonoike, K

    2003-01-01

    Institute for Radioprotection and Nuclear Safety (IRSN) and the OECD Nuclear Energy Agency (NEA) jointly organized SILENE Accident Dosimetry Intercomparison Exercise to intercompare the dose measurement systems of participating countries. Each participating country carried out dose measurements in the same irradiation field, and the measurement results were mutually compared. The participated in the exercise to measure the doses of gamma rays and neutron from SILENE by using thermoluminescence dosimeters (TLD's) and an alanine dosimeter. In this examination, the derived evaluation formulae for obtaining a tissue-absorbed dose from measured value (ambient dose equivalent) of TLD for neutron. We reported the tissue-absorbed dose computed using this evaluation formula to OECD/NEA. TLD's for neutron were irradiated in the TRACY facility to verify the evaluation formulae. The results of TLD's were compared with the calculations of MCNP and measurements with alanine dose meter. We found that the ratio of the dose b...

  5. Online radiation dose measurement system for ATLAS experiment

    Energy Technology Data Exchange (ETDEWEB)

    Mandic, I.; Cindro, V.; Dolenc, I.; Gorisek, A.; Kramberger, G. [Jozef Stefan Institute, Jamova 39, Ljubljana (Slovenia); Mikuz, M. [Jozef Stefan Institute, Jamova 39, Ljubljana (Slovenia); Faculty of Mathematics and Physics, University of Ljubljana (Slovenia); Bronner, J.; Hartet, J. [Physikalisches Institut, Universitat Freiburg, Hermann-Herder-Str. 3, Freiburg (Germany); Franz, S. [CERN, Geneva (Switzerland)

    2009-07-01

    In experiments at Large Hadron Collider, detectors and electronics will be exposed to high fluxes of photons, charged particles and neutrons. Damage caused by the radiation will influence performance of detectors. It will therefore be important to continuously monitor the radiation dose in order to follow the level of degradation of detectors and electronics and to correctly predict future radiation damage. A system for online radiation monitoring using semiconductor radiation sensors at large number of locations has been installed in the ATLAS experiment. Ionizing dose in SiO{sub 2} will be measured with RadFETs, displacement damage in silicon in units of 1-MeV(Si) equivalent neutron fluence with p-i-n diodes. At 14 monitoring locations where highest radiation levels are expected the fluence of thermal neutrons will be measured from current gain degradation in dedicated bipolar transistors. The design of the system and tests of its performance in mixed radiation field is described in this paper. First results from this test campaign confirm that doses can be measured with sufficient sensitivity (mGy for total ionizing dose measurements, 10{sup 9} n/cm{sup 2} for NIEL (non-ionizing energy loss) measurements, 10{sup 12} n/cm{sup 2} for thermal neutrons) and accuracy (about 20%) for usage in the ATLAS detector

  6. An international intercomparison of absorbed dose measurements for radiation therapy

    International Nuclear Information System (INIS)

    Taiman Kadni; Noriah Mod Ali

    2002-01-01

    Dose intercomparison on an international basis has become an important component of quality assurance measurement i.e. to check the performance of absorbed dose measurements in radiation therapy. The absorbed dose to water measurements for radiation therapy at the SSDL, MINT have been regularly compared through international intercomparison programmes organised by the IAEA Dosimetry Laboratory, Seibersdorf, Austria such as IAEA/WHO TLD postal dose quality audits and the Intercomparison of therapy level ionisation chamber calibration factors in terms of air kerma and absorbed dose to water calibration factors. The results of these intercomparison in terms of percentage deviations for Cobalt 60 gamma radiation and megavoltage x-ray from medical linear accelerators participated by the SSDL-MINT during the year 1985-2001 are within the acceptance limit. (Author)

  7. effect of ascorbic acid and/or sodium chloride on irradiated mungbean seeds

    International Nuclear Information System (INIS)

    Hussein, O.S.

    2010-01-01

    dry seeds of mungbean (Vigna radiata L.) were irradiated with different doses of gamma rays (0, 50, 100, 250 Gy) dose rate was 1.33 Gy/sec and germinated under laboratory conditions (28 degree C±2 degree C) in 100 mM of sodium chloride or 10 mM ascorbic acid or mixture of both in equal amounts . a group of irradiated and unirradiated seeds were moistened with tap water and considered as control. the growth parameters of two weeks old seedling were recorded. photosynthetic pigments, total carbohydrates, crud protein and amino acids contents were also determined. gamma radiation (50-100 Gy)increased total chlorophylls and carotenoid pigments while the highest dose of irradiation (250 Gy) reduced these contents. saline condition decreased total chlorophyll and carotenoid contents of seedlings resulted from irradiated seeds than control. adding of ascorbic acid to irradiated mungbean seeds in presence of NaCl overcame partially the inhibitory effect of NaCl on chlorophyll and carotenoid contents of seedlings. the pattern of changes in amino acids content was more or less similar to that of photosynthetic pigments.

  8. KERMA-based radiation dose management system for real-time patient dose measurement

    Science.gov (United States)

    Kim, Kyo-Tae; Heo, Ye-Ji; Oh, Kyung-Min; Nam, Sang-Hee; Kang, Sang-Sik; Park, Ji-Koon; Song, Yong-Keun; Park, Sung-Kwang

    2016-07-01

    Because systems that reduce radiation exposure during diagnostic procedures must be developed, significant time and financial resources have been invested in constructing radiation dose management systems. In the present study, the characteristics of an existing ionization-based system were compared to those of a system based on the kinetic energy released per unit mass (KERMA). Furthermore, the feasibility of using the KERMA-based system for patient radiation dose management was verified. The ionization-based system corrected the effects resulting from radiation parameter perturbations in general radiography whereas the KERMA-based system did not. Because of this difference, the KERMA-based radiation dose management system might overestimate the patient's radiation dose due to changes in the radiation conditions. Therefore, if a correction factor describing the correlation between the systems is applied to resolve this issue, then a radiation dose management system can be developed that will enable real-time measurement of the patient's radiation exposure and acquisition of diagnostic images.

  9. Direct measurement of the pulse duration and frequency chirp of seeded XUV free electron laser pulses

    Science.gov (United States)

    Azima, Armin; Bödewadt, Jörn; Becker, Oliver; Düsterer, Stefan; Ekanayake, Nagitha; Ivanov, Rosen; Kazemi, Mehdi M.; Lamberto Lazzarino, Leslie; Lechner, Christoph; Maltezopoulos, Theophilos; Manschwetus, Bastian; Miltchev, Velizar; Müller, Jost; Plath, Tim; Przystawik, Andreas; Wieland, Marek; Assmann, Ralph; Hartl, Ingmar; Laarmann, Tim; Rossbach, Jörg; Wurth, Wilfried; Drescher, Markus

    2018-01-01

    We report on a direct time-domain measurement of the temporal properties of a seeded free-electron laser pulse in the extreme ultraviolet spectral range. Utilizing the oscillating electromagnetic field of terahertz radiation, a single-shot THz streak-camera was applied for measuring the duration as well as spectral phase of the generated intense XUV pulses. The experiment was conducted at FLASH, the free electron laser user facility at DESY in Hamburg, Germany. In contrast to indirect methods, this approach directly resolves and visualizes the frequency chirp of a seeded free-electron laser (FEL) pulse. The reported diagnostic capability is a prerequisite to tailor amplitude, phase and frequency distributions of FEL beams on demand. In particular, it opens up a new window of opportunities for advanced coherent spectroscopic studies making use of the high degree of temporal coherence expected from a seeded FEL pulse.

  10. Measurements and applications of dose indices in radiography

    International Nuclear Information System (INIS)

    Chen, T.R.; Tyan, Y.S.; Yang, J.J.; Shao, C.H.; Lin, J.Y.; Tung, C.J.

    2011-01-01

    Assessments of radiation dose and image quality are required in diagnostic radiography for quality assurance and optimization studies. In work currently being undertaken, dose indices were measured and image quality evaluated for a chest PA procedure. Thermoluminescent dosimeters of the GR-200 type were attached to the entrance and exit surfaces and placed at various depths of the PMMA phantom to measure the entrance surface dose, the exit surface dose, and the organ dose index. The effective dose was estimated from the entrance surface dose using PCXMC software. Two contrast-detail image plates, one with air holes for the low contrast objects and the other with gypsum holes for the high contrast objects, were used to obtain radiographic images. This image plate was placed at different depths from the entrance surface of the phantom to simulate objects at different positions in the body. Each image was evaluated by three independent radiologists to determine image quality. Analyses of radiation dose versus image quality were performed to determine the optimal technical factors such as, filtration and tube potential. It was found that an 11-cm thick PMMA phantom best simulated the patients. The fractional dose backscattered from this phantom was between 22% and 27% for kVp’s between 66 and 133. Optimization analyses showed that no extra filter was required. For low contrast objects, an optimal choice of tube potential was 120 kVp. For high contrast objects, a kVp as low as 77 kVp could be used, depending on the image quality requirement.

  11. Some cosmic radiation dose measurements aboard flights connecting Zagreb Airport

    International Nuclear Information System (INIS)

    Vukovic, B.; Radolic, V.; Lisjak, I.; Vekic, B.; Poje, M.; Planinic, J.

    2008-01-01

    When primary particles from space, mainly protons, enter the atmosphere, they produce interactions with air nuclei, and cosmic-ray showers are induced. The radiation field at aircraft altitude is complex, with different types of particles, mainly photons, electrons, positrons and neutrons, with a large energy range. The non-neutron component of cosmic radiation dose aboard A320 and ATR40 aircraft was measured with TLD-100 (LiF:Mg,Ti) detectors and the Mini 6100 semiconductor dosimeter; the neutron dose was measured with the neutron dosimeter consisted of LR-115 track detector and boron foil BN-1 or 10 B converter. The estimated occupational effective dose for the aircraft crew (A320) working 500 h per year was 1.64 mSv. Another experiment was performed at the flights Zagreb-Paris-Buenos Aires and reversely, when one measured non-neutron cosmic radiation dose; for 26.7 h of flight, the MINI 6100 dosimeter gave an average dose rate of 2.3 μSv/h and the TLD dosimeter registered the dose equivalent of 75 μSv or the average dose rate of 2.7 μSv/h; the neutron dosimeter gave the dose rate of 2.4 μSv/h. In the same month, February 2005, a traveling to Japan (24-h-flight: Zagreb-Frankfurt-Tokyo and reversely) and the TLD-100 measurement showed the average dose rate of 2.4 μSv/h; the neutron dosimeter gave the dose rate of 2.5 μSv/h. Comparing dose rates of the non-neutron component (low LET) and the neutron one (high LET) of the radiation field at the aircraft flight level, we could conclude that the neutron component carried about 50% of the total dose, that was near other known data

  12. Some cosmic radiation dose measurements aboard flights connecting Zagreb Airport

    Energy Technology Data Exchange (ETDEWEB)

    Vukovic, B.; Radolic, V. [Department of Physics, University of Osijek, Osijek, P.O. Box 125 (Croatia); Lisjak, I. [Croatia Airlines, Zagreb (Croatia); Vekic, B. [Rudjer Boskovic Institute, Zagreb (Croatia); Poje, M. [Department of Physics, University of Osijek, Osijek, P.O. Box 125 (Croatia); Planinic, J. [Department of Physics, University of Osijek, Osijek, P.O. Box 125 (Croatia)], E-mail: planinic@ffos.hr

    2008-02-15

    When primary particles from space, mainly protons, enter the atmosphere, they produce interactions with air nuclei, and cosmic-ray showers are induced. The radiation field at aircraft altitude is complex, with different types of particles, mainly photons, electrons, positrons and neutrons, with a large energy range. The non-neutron component of cosmic radiation dose aboard A320 and ATR40 aircraft was measured with TLD-100 (LiF:Mg,Ti) detectors and the Mini 6100 semiconductor dosimeter; the neutron dose was measured with the neutron dosimeter consisted of LR-115 track detector and boron foil BN-1 or {sup 10}B converter. The estimated occupational effective dose for the aircraft crew (A320) working 500 h per year was 1.64 mSv. Another experiment was performed at the flights Zagreb-Paris-Buenos Aires and reversely, when one measured non-neutron cosmic radiation dose; for 26.7 h of flight, the MINI 6100 dosimeter gave an average dose rate of 2.3 {mu}Sv/h and the TLD dosimeter registered the dose equivalent of 75 {mu}Sv or the average dose rate of 2.7 {mu}Sv/h; the neutron dosimeter gave the dose rate of 2.4 {mu}Sv/h. In the same month, February 2005, a traveling to Japan (24-h-flight: Zagreb-Frankfurt-Tokyo and reversely) and the TLD-100 measurement showed the average dose rate of 2.4 {mu}Sv/h; the neutron dosimeter gave the dose rate of 2.5 {mu}Sv/h. Comparing dose rates of the non-neutron component (low LET) and the neutron one (high LET) of the radiation field at the aircraft flight level, we could conclude that the neutron component carried about 50% of the total dose, that was near other known data.

  13. Sensitivity of Canola Seeds Associated Fungi to Gamma Rays During Storage

    International Nuclear Information System (INIS)

    Botros, H.W.

    2011-01-01

    The present study was carried out to investigate the possibility of using the gamma radiation to elongate the storage periods of canola seeds (Brassica naps L.). In this respect, canola seeds were irradiated at doses of 0.5, 1.5, 2.5, 3.5, 5.0 and 7.5 kGy gamma rays and stored at room temperature for periods 0, 3, 6, 9 and 12 months. The isolated fungi from non-irradiated post-harvest canola seeds included different species identified as Aspergillus flavus, A. niger, A. condidus, A. fumigatus, A. ochraceus, A. parasiticus, Fusarium oxysporium, F. moniliforme, Penicillium expansum, P. crysogenum, Alternaria brassicae, A. raphani and Trichoderma spp. It was noticed that the predominant species were A. ochraceus, A. flavus, A. niger and F. oxysporium at percentages 16.18, 14.73, 11.00 and 10.53%, respectively. The effective gamma irradiation on the predominant fungi (the sub-lethal dose) was 3.5 kGy for A. ochraceus and 5.0 kGy for F. oxysporium and F. moniliforme. Increasing the irradiated dose up to 7.5 kGy decreased significantly the growth of most isolated fungi. The data also showed that there was a decrease in the total fungal count in stored seeds under the effect of gamma rays for 12 months storage. Also, mycotoxins at the stored seeds were not detected after 12 months storage

  14. Effects of the irradiation in seeds of cotton

    International Nuclear Information System (INIS)

    Araujo, Ana Leticia; Arthur, Paula Bergamin; Arthur, Valter; Franco, Camilo Flamorion de Oliveira

    2017-01-01

    The experiment aimed to verify if seeds of cotton of variety FiberMax FM 993, irradiated with the doses of 0 (test); 25; 50; 75; 100 Gy can induce the production increase in cotton culture. For all treatments with irradiation, was used a source of cobalt-60, type Gammacell 220. After the irradiation, the seeds were planted in the experimental field of the Department of Plant Production ESALQ-USP, Piracicaba-SP. The experimental design was randomized blocks with four replications and 60 g of seed were used for each repetition, the rows were 5m and the spacing of 0.90m, using randomized blocks and rows of edging. After planting the final height and productivity were evaluated. The obtained data were statistically analyzed in the Tukey test at 5% level of probability. From the results obtained, it was concluded that the dose of 50Gy was the one that induced a greater production of cotton. (author)

  15. Effects of the irradiation in seeds of cotton

    Energy Technology Data Exchange (ETDEWEB)

    Araujo, Ana Leticia [Centro de Energia Nuclear na Agricultura (CENA/USP), Piracicaba, SP (Brazil); Arthur, Paula Bergamin; Arthur, Valter, E-mail: paula.arthur@hotmail.com [Instituto de Pesquisas Energéticas e Nucleares (IPEN/CNEN-SP), São Paulo, SP (Brazil); Franco, Camilo Flamorion de Oliveira [Empresa Brasileira de Pesquisa Agropecuária (EMBRAPA/EMEPA), João Pessoa, PB (Brazil)

    2017-07-01

    The experiment aimed to verify if seeds of cotton of variety FiberMax FM 993, irradiated with the doses of 0 (test); 25; 50; 75; 100 Gy can induce the production increase in cotton culture. For all treatments with irradiation, was used a source of cobalt-60, type Gammacell 220. After the irradiation, the seeds were planted in the experimental field of the Department of Plant Production ESALQ-USP, Piracicaba-SP. The experimental design was randomized blocks with four replications and 60 g of seed were used for each repetition, the rows were 5m and the spacing of 0.90m, using randomized blocks and rows of edging. After planting the final height and productivity were evaluated. The obtained data were statistically analyzed in the Tukey test at 5% level of probability. From the results obtained, it was concluded that the dose of 50Gy was the one that induced a greater production of cotton. (author)

  16. [Testing methods for seed quality of Bletilla striata].

    Science.gov (United States)

    Zhang, Zhi-Hui; Liu, Da-Hui; Zhu, Xin-Yan; Ji, Peng-Zhang; Wang, Li; Shi, Ya-Na; Ma, Cong-Ji

    2016-06-01

    In order to provide a basis for establishing seed testing rules and seed quality standard of Bletilla striata, the seed quality of B.striata from different producing area was measured referring to the Rules for Agricultural Seed Testing(GB/T 3543-1995).The results showed that the seeds of B.striata passed through 20-mesh sieve for purity analysis.The weight of seeds was measured by 1000-seed method and the water content was measured at the higher temperature (133±2) ℃ for 3 hours.The seeds were cultured on the wet filter paper at 30 ℃ for 4-20 days in light for germination testing.The method of testing seed viability was that seeds were dipped into 1% TTC solution for 7 hours at temperature of 40 ℃. Copyright© by the Chinese Pharmaceutical Association.

  17. Effects of gamma irradiation on fungal load and Mycotoxin on Sesame seeds in Abuja, Nigeria

    International Nuclear Information System (INIS)

    Akueche, E.C.; Kana, N.D.; Adeboye, E.T.; Adeleke, A. T.; Shehu, I.; Akande, R.; Shonowo, O. A.; Adesanmi, C.A.; Anjorin, S.T.

    2011-01-01

    Gamma rays of average energy of 1.25 MeV from radionuclide 60 Co was used in this study and the effects of varying doses 3, 6, 9, 12, 15 kGy on fungal load of and mycotoxin content on sesame seeds were investigated. Sesame seed samples were collected from Abaji, Gwagwalada, Kubwa and Karu markets in Abuja, Federal Capital Territory, Nigeria. A serial dilution technique was employed and the fungi so diluted from the sesame seed samples were identified based on micro and macro morphological characteristics. The Aflatoxin Total and Ochratoxin A Contents in the samples were analysed using AgraQaunt direct combative enzyme-linked immunosorbent assay (ELISA). In all, 157 fungal isolates to four genera: Aspergillus, Curvularia, Penicillium, and Fusarium spp. in decreasing order of predominance were identified. Aspergillus spp. were observed from all the nonirradiated samples. Doses of 6-15kGy eliminated the entire fungal load. Also doses of 9-15kGy generally reduced Ochratoxin A content in all the samples, the rate of mycotoxin reduction was inconsistent with absorbed dose. However, sesame seed samples from the four markets exposed to irradiation dose of 15kGy had the comparatively least Aflatoxin Total content.

  18. Verification of eye lens dose in IMRT by MOSFET measurement.

    Science.gov (United States)

    Wang, Xuetao; Li, Guangjun; Zhao, Jianling; Song, Ying; Xiao, Jianghong; Bai, Sen

    2018-04-17

    The eye lens is recognized as one of the most radiosensitive structures in the human body. The widespread use of intensity-modulated radiotherapy (IMRT) complicates dose verification and necessitates high standards of dose computation. The purpose of this work was to assess the computed dose accuracy of eye lens through measurements using a metal-oxide-semiconductor field-effect transistor (MOSFET) dosimetry system. Sixteen clinical IMRT plans of head and neck patients were copied to an anthropomorphic head phantom. Measurements were performed using the MOSFET dosimetry system based on the head phantom. Two MOSFET detectors were imbedded in the eyes of the head phantom as the left and the right lens, covered by approximately 5-mm-thick paraffin wax. The measurement results were compared with the calculated values with a dose grid size of 1 mm. Sixteen IMRT plans were delivered, and 32 measured lens doses were obtained for analysis. The MOSFET dosimetry system can be used to verify the lens dose, and our measurements showed that the treatment planning system used in our clinic can provide adequate dose assessment in eye lenses. The average discrepancy between measurement and calculation was 6.7 ± 3.4%, and the largest discrepancy was 14.3%, which met the acceptability criterion set by the American Association of Physicists in Medicine Task Group 53 for external beam calculation for multileaf collimator-shaped fields in buildup regions. Copyright © 2018 American Association of Medical Dosimetrists. Published by Elsevier Inc. All rights reserved.

  19. Application of combined TLD and CR-39 PNTD method for measurement of total dose and dose equivalent on ISS

    International Nuclear Information System (INIS)

    Benton, E.R.; Deme, S.; Apathy, I.

    2006-01-01

    To date, no single passive detector has been found that measures dose equivalent from ionizing radiation exposure in low-Earth orbit. We have developed the I.S.S. Passive Dosimetry System (P.D.S.), utilizing a combination of TLD in the form of the self-contained Pille TLD system and stacks of CR-39 plastic nuclear track detector (P.N.T.D.) oriented in three mutually orthogonal directions, to measure total dose and dose equivalent aboard the International Space Station (I.S.S.). The Pille TLD system, consisting on an on board reader and a large number of Ca 2 SO 4 :Dy TLD cells, is used to measure absorbed dose. The Pille TLD cells are read out and annealed by the I.S.S. crew on orbit, such that dose information for any time period or condition, e.g. for E.V.A. or following a solar particle event, is immediately available. Near-tissue equivalent CR-39 P.N.T.D. provides Let spectrum, dose, and dose equivalent from charged particles of LET ∞ H 2 O ≥ 10 keV/μm, including the secondaries produced in interactions with high-energy neutrons. Dose information from CR-39 P.N.T.D. is used to correct the absorbed dose component ≥ 10 keV/μm measured in TLD to obtain total dose. Dose equivalent from CR-39 P.N.T.D. is combined with the dose component <10 keV/μm measured in TLD to obtain total dose equivalent. Dose rates ranging from 165 to 250 μGy/day and dose equivalent rates ranging from 340 to 450 μSv/day were measured aboard I.S.S. during the Expedition 2 mission in 2001. Results from the P.D.S. are consistent with those from other passive detectors tested as part of the ground-based I.C.C.H.I.B.A.N. intercomparison of space radiation dosimeters. (authors)

  20. Results of Zea mays seeds β- irradiation in 0 - 5 Gy range

    International Nuclear Information System (INIS)

    Chicea, Dan; Racuciu, Mihaela

    2008-01-01

    In this study young plants, obtained from the control and beta irradiated seeds, were studied in laboratory experiments. Zea mays seeds with uniform genophond were irradiated with 90 Sr source in the 0 - 5 Gy range. Increased germination percentage was observed under the influence of different radiation doses. We found that small doses of β- radiation have a stimulating effect on the growth of the plantlets, the maximum simulation (among the doses we used) being induced by 0.615 Gy and is statistically significant. We investigated the chlorophyll a to b ratio and the average length variations with the irradiation dose and present the results. Key words: b- radiation, Zea mays, germination rate, plants growth, photoassimilatory pigments,

  1. Quality characteristics of irradiated sesame seeds during storage

    International Nuclear Information System (INIS)

    Swailam, H.M.

    2009-01-01

    The effect of using gamma radiation 60 Co on the microbial load , presence of some pathogens, viscosity, oil, fatty acids and amino acids properties of sesame seeds were investigated.The condition storage at ambient temperature (20-28 deg c) was held for one year. Pre-packaged sesame seeds were found to be heavily contaminated with bacteria and fungi. The total bacterial counts were 1,9x10 4 cfu/g,whereas total fungal counts were 3.4x10 4 cfu/g.Samples showed low number of the pathogenic bacterial in control . It was found that the microbiological population greatly reduced with a dose of 10 kGy without affecting their quality attributes , irradiation doses used linearly reduced the viscosity of sesame seeds samples. These irradiation doses caused a decrease in the content of some fatty acids and amino acids and increase in others. At the end of storage period, it is clear that , irradiation dose of 10 kGy greatly reduced the counts of total bacterial count, total fungal count and spore former bacterial to less than 10 cfu/ g. The average counts of faecal coliforms , staphylococcus aureus and enterococcus faecalis did not detected in samples receiving 5 and 10 kGy . the flow index (n) and consistency index (k) were decreased after 12 month of storage in irradiated sesame with 10 kGy. Also, there was a slight increase in acid and peroxide value of oil extracted from sesame seeds treatment with 10 kGy. Meanwhile, there was a decrease in iodine, saponification value and very little decrease in the refractive index. It was found that slightly decreased in total unsaturated fatty acid (0.12%) and total amino acid (0.63%)in sesame irradiated at 10 kGy . so, it can be concluded that 10 kGy of γ-radiation suffice the purpose of this work

  2. Effect of Papaya Seed Extract (Carica papaya Linn. on Glucose Transporter 4 (GLUT 4 Expression of Skeletal Muscle Tissue in Diabetic Mice Induced by High Fructose Diet

    Directory of Open Access Journals (Sweden)

    Devyani Diah Wulansari

    2017-08-01

    Full Text Available Ethnobotany surveys show that papaya seeds are widely used as herbs for the management of some diseases such as abdominal discomfort, pain, malaria, diabetes, obesity, and infection. This research was conducted to analyze the effect of papaya seed extract on GLUT4 expression on skeletal muscle tissue of DM type II model induced by high fructose diet. This study used 24 animals, divided into 4 groups of negative control group, treated with papaya seed extract 100 mg / kgBB, 200 mg / kgBW and 300 mg / kgBW, was adapted for 14 days then induced by fructose solution 20% Orally with a dose of 1.86 grams / kgBB for 56 days. The treatment group was given papaya seed extract in accordance with the dose of each group for 14 days. GDP levels was measured using a spectrophotometer. Skeletal muscle tissue is used on the gastrocnemius part. GLUT4 expression was measured through a Immunoreactive Score (IRS method with immunohistochemical staining using GLUT4 polyclonal antibodies. Comparative test results showed that there were significant differences between groups (p <0.05 in final GDP variables and GLUT4 expression. Pearson correlation test results show that the value p = 0.001, meaning there is a significant relationship between GLUT4 expression with final GDP levels. The result of simple linear regression analysis showed that p = 0,000 (<0,05, meaning that dose of papaya seed extract had a significant influence on GLUT4 expression.

  3. Measurements of the dose due to cosmic rays in aircraft

    International Nuclear Information System (INIS)

    Vukovic, B.; Lisjak, I.; Radolic, V.; Vekic, B.; Planinic, J.

    2006-01-01

    When the primary particles from space, mainly protons, enter the atmosphere, they produce interactions with air nuclei, and cosmic-ray showers are induced. The radiation field at aircraft altitude is complex, with different types of particles, mainly photons, electrons, positrons and neutrons, with a large energy range. The cosmic radiation dose aboard A320 and ATR 42 aircraft was measured with TLD-100 (LiF:Mg,Ti) detectors and the Mini 6100 semiconductor dosimeter; radon concentration in the atmosphere was measured with the Alpha Guard radon detector. The estimated occupational effective dose for the aircraft crew (A320) working 500 h per year was 1.64 mSv. Another experiment was performed by the flights Zagreb-Paris-Buenos Aires and reversely, when one measured cosmic radiation dose; for 26.7 h of flight, the TLD dosimeter registered the total dose of 75 μSv and the average dose rate was 2.7 μSv/h. In the same month, February 2005, a traveling to Japan (24 h flight: Zagreb-Frankfurt-Tokyo and reversely) and the TLD-100 measurement showed the average dose rate of 2.4 μSv/h

  4. Measurements of the dose due to cosmic rays in aircraft

    Energy Technology Data Exchange (ETDEWEB)

    Vukovic, B. [Department of Physics, University of Osijek, Osijek, P.O. Box 125 (Croatia); Lisjak, I. [Croatia Airlines, Zagreb (Croatia); Radolic, V. [Department of Physics, University of Osijek, Osijek, P.O. Box 125 (Croatia); Vekic, B. [Rudjer Boskovic Institute, Zagreb (Croatia); Planinic, J. [Department of Physics, University of Osijek, Osijek, P.O. Box 125 (Croatia)]. E-mail: planinic@ffos.hr

    2006-06-15

    When the primary particles from space, mainly protons, enter the atmosphere, they produce interactions with air nuclei, and cosmic-ray showers are induced. The radiation field at aircraft altitude is complex, with different types of particles, mainly photons, electrons, positrons and neutrons, with a large energy range. The cosmic radiation dose aboard A320 and ATR 42 aircraft was measured with TLD-100 (LiF:Mg,Ti) detectors and the Mini 6100 semiconductor dosimeter; radon concentration in the atmosphere was measured with the Alpha Guard radon detector. The estimated occupational effective dose for the aircraft crew (A320) working 500 h per year was 1.64 mSv. Another experiment was performed by the flights Zagreb-Paris-Buenos Aires and reversely, when one measured cosmic radiation dose; for 26.7 h of flight, the TLD dosimeter registered the total dose of 75 {mu}Sv and the average dose rate was 2.7 {mu}Sv/h. In the same month, February 2005, a traveling to Japan (24 h flight: Zagreb-Frankfurt-Tokyo and reversely) and the TLD-100 measurement showed the average dose rate of 2.4 {mu}Sv/h.

  5. Practical considerations for maximizing heat production in a novel thermobrachytherapy seed prototype

    Energy Technology Data Exchange (ETDEWEB)

    Gautam, Bhoj; Warrell, Gregory; Shvydka, Diana; Ishmael Parsai, E., E-mail: e.parsai@utoledo.edu [University of Toledo Medical Center, 3000 Arlington Avenue, MS1151, Toledo, Ohio 43614 (United States); Subramanian, Manny [BEST Medical International, Inc., 7643 Fullerton Road, Springfield, Virginia 22153 (United States)

    2014-02-15

    Purpose: A combination of hyperthermia and radiation in the treatment of cancer has been proven to provide better tumor control than radiation administered as a monomodality, without an increase in complications or serious toxicities. Moreover, concurrent administration of hyperthermia and radiation displays synergistic enhancement, resulting in greater tumor cell killing than hyperthermia and radiation delivered separately. The authors have designed a new thermobrachytherapy (TB) seed, which serves as a source of both radiation and heat for concurrent brachytherapy and hyperthermia treatments when implanted in solid tumors. This innovative seed, similar in size and geometry to conventional seeds, will have self-regulating thermal properties. Methods: The new seed's geometry is based on the standard BEST Model 2301{sup 125}I seed, resulting in very similar dosimetric properties. The TB seed generates heat when placed in an oscillating magnetic field via induction heating of a ferromagnetic Ni–Cu alloy core that replaces the tungsten radiographic marker of the standard Model 2301. The alloy composition is selected to undergo a Curie transition near 50 °C, drastically decreasing power production at higher temperatures and providing for temperature self-regulation. Here, the authors present experimental studies of the magnetic properties of Ni–Cu alloy material, the visibility of TB seeds in radiographic imaging, and the ability of seed prototypes to uniformly heat tissue to a desirable temperature. Moreover, analyses are presented of magnetic shielding and thermal expansion of the TB seed, as well as matching of radiation dose to temperature distributions for a short interseed distance in a given treatment volume. Results: Annealing the Ni–Cu alloy has a significant effect on its magnetization properties, increasing the sharpness of the Curie transition. The TB seed preserves the radiographic properties of the BEST 2301 seed in both plain x rays and CT

  6. Practical considerations for maximizing heat production in a novel thermobrachytherapy seed prototype

    International Nuclear Information System (INIS)

    Gautam, Bhoj; Warrell, Gregory; Shvydka, Diana; Ishmael Parsai, E.; Subramanian, Manny

    2014-01-01

    Purpose: A combination of hyperthermia and radiation in the treatment of cancer has been proven to provide better tumor control than radiation administered as a monomodality, without an increase in complications or serious toxicities. Moreover, concurrent administration of hyperthermia and radiation displays synergistic enhancement, resulting in greater tumor cell killing than hyperthermia and radiation delivered separately. The authors have designed a new thermobrachytherapy (TB) seed, which serves as a source of both radiation and heat for concurrent brachytherapy and hyperthermia treatments when implanted in solid tumors. This innovative seed, similar in size and geometry to conventional seeds, will have self-regulating thermal properties. Methods: The new seed's geometry is based on the standard BEST Model 2301 125 I seed, resulting in very similar dosimetric properties. The TB seed generates heat when placed in an oscillating magnetic field via induction heating of a ferromagnetic Ni–Cu alloy core that replaces the tungsten radiographic marker of the standard Model 2301. The alloy composition is selected to undergo a Curie transition near 50 °C, drastically decreasing power production at higher temperatures and providing for temperature self-regulation. Here, the authors present experimental studies of the magnetic properties of Ni–Cu alloy material, the visibility of TB seeds in radiographic imaging, and the ability of seed prototypes to uniformly heat tissue to a desirable temperature. Moreover, analyses are presented of magnetic shielding and thermal expansion of the TB seed, as well as matching of radiation dose to temperature distributions for a short interseed distance in a given treatment volume. Results: Annealing the Ni–Cu alloy has a significant effect on its magnetization properties, increasing the sharpness of the Curie transition. The TB seed preserves the radiographic properties of the BEST 2301 seed in both plain x rays and CT images

  7. Sci-Sat AM(2): Brachy-05: Dosimetry effects of the TG-43 approximations for two iodine seeds in LDR brachytherapy.

    Science.gov (United States)

    Furstoss, C; Bertrand, M J; Poon, E; Reniers, B; Pignol, J P; Carrier, J F; Beaulieu, L; Verhaegen, F

    2008-07-01

    This work consists of studying the interseed and tissue composition effects for two model iodine seeds: the IBt Interseed-125 and the 6711 model seed. Three seeds were modeled with the MCNP MC code in a water sphere to evaluate the interseed effect. The dose calculated at different distances from the centre was compared to the dose summed when the seeds were simulated separately. The tissue composition effect was studied calculating the radial dose function for different tissues. Before carrying out post-implant studies, the absolute dose calculated by MC was compared to experiment results: with LiF TLDs in an acrylic breast phantom and with an EBT Gafchromic film placed in a water tank. Afterwards, the TG-43 approximation effects were studied for a prostate and breast post-implant. The interseed effect study shows that this effect is more important for model 6711 (15%) than for IBt (10%) due to the silver rod in 6711. For both seed models the variations of the radial dose function as a function of the tissue composition are quasi similar. The absolute dose comparisons between MC calculations and experiments give good agreement (inferior to 3% in general). For the prostate and breast post-implant studies, a 10% difference between MC calculations and the TG-43 is found for both models of seeds. This study shows that the differences in dose distributions between TG43 and MC are quite similar for the two models of seeds and are about 10% for the studied post-implant treatments. © 2008 American Association of Physicists in Medicine.

  8. Effect of different seed treatments on maize seed germination parameters under optimal and suboptimal temperature conditions

    Directory of Open Access Journals (Sweden)

    Vujošević Bojana

    2017-01-01

    Full Text Available The aim of this study was to determine the effect of different seed treatments on germination parameters of three maize genotypes under optimal and suboptimal temperature conditions. Seed was treated with recommended doses of three commercial pesticide formulations: metalaxyl-m 10 g/L + fludioxonil 25 g/L, metalaxyl 20 g/kg + prothioconazole 100 g/kg and thiacloprid 400 g/L. Testing was conducted at 25°C and 15°C. Results of the study indicate that there are differences in response of maize genotypes to applied seed treatments, as well as to a specific treatment at optimal and suboptimal temperatures. Some treatments, depending on the mixing partner and temperature conditions, can affect final germination. In other cases, germination rate can be accelerated or prolonged, but with no effect on final germination. In order to provide fast and uniform emergence under different temperature conditions, further examination of the response of maize genotypes to specific seed treatments would be beneficial.

  9. Proton dose distribution measurements using a MOSFET detector with a simple dose-weighted correction method for LET effects.

    Science.gov (United States)

    Kohno, Ryosuke; Hotta, Kenji; Matsuura, Taeko; Matsubara, Kana; Nishioka, Shie; Nishio, Teiji; Kawashima, Mitsuhiko; Ogino, Takashi

    2011-04-04

    We experimentally evaluated the proton beam dose reproducibility, sensitivity, angular dependence and depth-dose relationships for a new Metal Oxide Semiconductor Field Effect Transistor (MOSFET) detector. The detector was fabricated with a thinner oxide layer and was operated at high-bias voltages. In order to accurately measure dose distributions, we developed a practical method for correcting the MOSFET response to proton beams. The detector was tested by examining lateral dose profiles formed by protons passing through an L-shaped bolus. The dose reproducibility, angular dependence and depth-dose response were evaluated using a 190 MeV proton beam. Depth-output curves produced using the MOSFET detectors were compared with results obtained using an ionization chamber (IC). Since accurate measurements of proton dose distribution require correction for LET effects, we developed a simple dose-weighted correction method. The correction factors were determined as a function of proton penetration depth, or residual range. The residual proton range at each measurement point was calculated using the pencil beam algorithm. Lateral measurements in a phantom were obtained for pristine and SOBP beams. The reproducibility of the MOSFET detector was within 2%, and the angular dependence was less than 9%. The detector exhibited a good response at the Bragg peak (0.74 relative to the IC detector). For dose distributions resulting from protons passing through an L-shaped bolus, the corrected MOSFET dose agreed well with the IC results. Absolute proton dosimetry can be performed using MOSFET detectors to a precision of about 3% (1 sigma). A thinner oxide layer thickness improved the LET in proton dosimetry. By employing correction methods for LET dependence, it is possible to measure absolute proton dose using MOSFET detectors.

  10. Measurement of absorbed dose with a bone-equivalent extrapolation chamber

    International Nuclear Information System (INIS)

    DeBlois, Francois; Abdel-Rahman, Wamied; Seuntjens, Jan P.; Podgorsak, Ervin B.

    2002-01-01

    A hybrid phantom-embedded extrapolation chamber (PEEC) made of Solid Water trade mark sign and bone-equivalent material was used for determining absorbed dose in a bone-equivalent phantom irradiated with clinical radiation beams (cobalt-60 gamma rays; 6 and 18 MV x rays; and 9 and 15 MeV electrons). The dose was determined with the Spencer-Attix cavity theory, using ionization gradient measurements and an indirect determination of the chamber air-mass through measurements of chamber capacitance. The collected charge was corrected for ionic recombination and diffusion in the chamber air volume following the standard two-voltage technique. Due to the hybrid chamber design, correction factors accounting for scatter deficit and electrode composition were determined and applied in the dose equation to obtain absorbed dose in bone for the equivalent homogeneous bone phantom. Correction factors for graphite electrodes were calculated with Monte Carlo techniques and the calculated results were verified through relative air cavity dose measurements for three different polarizing electrode materials: graphite, steel, and brass in conjunction with a graphite collecting electrode. Scatter deficit, due mainly to loss of lateral scatter in the hybrid chamber, reduces the dose to the air cavity in the hybrid PEEC in comparison with full bone PEEC by 0.7% to ∼2% depending on beam quality and energy. In megavoltage photon and electron beams, graphite electrodes do not affect the dose measurement in the Solid Water trade mark sign PEEC but decrease the cavity dose by up to 5% in the bone-equivalent PEEC even for very thin graphite electrodes (<0.0025 cm). In conjunction with appropriate correction factors determined with Monte Carlo techniques, the uncalibrated hybrid PEEC can be used for measuring absorbed dose in bone material to within 2% for high-energy photon and electron beams

  11. SU-E-J-198: Out-Of-Field Dose and Surface Dose Measurements of MRI-Guided Cobalt-60 Radiotherapy

    International Nuclear Information System (INIS)

    Lamb, J; Agazaryan, N; Cao, M; Low, D; Thomas, D; Yang, Y

    2015-01-01

    Purpose: To measure quantities of dosimetric interest in an MRI-guided cobalt radiotherapy machine that was recently introduced to clinical use. Methods: Out-of-field dose due to photon scatter and leakage was measured using an ion chamber and solid water slabs mimicking a human body. Surface dose was measured by irradiating stacks of radiochromic film and extrapolating to zero thickness. Electron out-of-field dose was characterized using solid water slabs and radiochromic film. Results: For some phantom geometries, up to 50% of Dmax was observed up to 10 cm laterally from the edge of the beam. The maximum penetration was between 1 and 2 mm in solid water, indicating an electron energy not greater than approximately 0.4 MeV. Out-of-field dose from photon scatter measured at 1 cm depth in solid water was found to fall to less than 10% of Dmax at a distance of 1.2 cm from the edge of a 10.5 × 10.5 cm field, and less that 1% of Dmax at a distance of 10 cm from field edge. Surface dose was measured to be 8% of Dmax. Conclusion: Surface dose and out-of-field dose from the MRIguided cobalt radiotherapy machine was measured and found to be within acceptable limits. Electron out-of-field dose, an effect unique to MRI-guided radiotherapy and presumed to arise from low-energy electrons trapped by the Lorentz force, was quantified. Dr. Low is a member of the scientific advisory board of ViewRay, Inc

  12. Analytical evaluation of dose measurement of critical accident at SILENE (Contract research)

    Energy Technology Data Exchange (ETDEWEB)

    Nakamura, Takemi; Tonoike, Kotaro; Miyoshi, Yoshinori [Japan Atomic Energy Research Inst., Tokai, Ibaraki (Japan). Tokai Research Establishment

    2003-03-01

    Institute for Radioprotection and Nuclear Safety (IRSN) and the OECD Nuclear Energy Agency (NEA) jointly organized SILENE Accident Dosimetry Intercomparison Exercise to intercompare the dose measurement systems of participating countries. Each participating country carried out dose measurements in the same irradiation field, and the measurement results were mutually compared. The authors participated in the exercise to measure the doses of gamma rays and neutron from SILENE by using thermoluminescence dosimeters (TLD's) and an alanine dosimeter. In this examination, the authors derived evaluation formulae for obtaining a tissue-absorbed dose from measured value (ambient dose equivalent) of TLD for neutron. We reported the tissue-absorbed dose computed using this evaluation formula to OECD/NEA. TLD's for neutron were irradiated in the TRACY facility to verify the evaluation formulae. The results of TLD's were compared with the calculations of MCNP and measurements with alanine dose meter. We found that the ratio of the dose by the evaluation formula to the measured value by the alanine dosimeter was 0.94 and the formula agreed within 6%. From examination of this TRACY, we can conclude that the value reported to OECD/NEA has equivalent accuracy. (author)

  13. Measurement of annual dose on porcelain using surface TLD method

    International Nuclear Information System (INIS)

    Xia Junding; Wang Weida; Leung, P.L.

    2001-01-01

    In order to improve accuracy of TL authentication test for porcelain, a method of measurement of annual dose using ultrathin (CaSO 4 :Tm) dosage layer on porcelain was studied. The TLD was placed on the part of porcelain without glaze. A comparison of measurement of annual dose for surface TLD, inside TLD and alpha counting on porcelain was made. The results show that this technique is suitable for measuring annual dose and improving accuracy of TL authentication test for both porcelain and pottery

  14. Irradiation sensibility of different provenances of Jatropha curcas L. seeds

    International Nuclear Information System (INIS)

    Yang Qing; Xu Congheng; Peng Daiping; Duan Zhubiao; Han Lei; Sun Qixiang; Peng Zhenhua

    2007-01-01

    The irradiation sensibility of 10 provenances of Jatropha curcas L. seeds to 60 Co γ-rays was studied. The results showed that the relationship between relative germination rate of the seeds and the doses of irradiation was negative correlation, and the difference of relative germination rate among different doses treatment was significant at 5% probability level or highly significant at 1% probability level. For seeds of different provenances, the correlation coefficient of linear regression was from -0.89--0.96, and the medial lethal doses (LD 50) of 10 provinces was from 127 Gy to 184 Gy. According to the LD 50, we could divided 10 provinces of J. curcas L. into sensitive provenance, transitional provenances and obtuse provenances. The provenances of Yuanjiang , Yunan (184 Gy) belonged to sensitive provenance; the provenances of Zhenfeng, Guizhou (127 Gy) and the provenances of Yuedong, Hainan (141 Gy) belonged to obtuse provenance; other 7 provenances belonged to transitional provenances. The results provided important experiment basis for germ plasma resources innovation of J. curcas L. (authors)

  15. Effect Of CARICAPRYL-99 Seed Alkaloid Extract On The Serum ...

    African Journals Online (AJOL)

    Summary: Activity of alkaloid extract of caricapryl–99 seeds (Carica papaya Linn seeds) on the serum levels of steroid hormones was studied in adult male albino rats. Three tolerated doses obtained from the graph of percectage toxicity (10, 50 and 150 mg/kg) were separately administered orally, daily for three days to ...

  16. Indexes of the common reed's seed vitality from water-bodies of the Chernobyl exclusive zone

    International Nuclear Information System (INIS)

    Yavnuk, A.A.; Shevtsova, N.L.; Gudkov, D.I.; Levchenko, Ya.I.

    2010-01-01

    Investigation of the common reed's seed vitality (vegetation of 2009) from flood-plain water-bodies with different level of radionuclide contamination was carried out. Decrease in indexes of seed's vitality and abnormalities in seed dynamic sprouting was noticed. Dose-response relationship of germination, germinating force, survival rate of seeds of plants was determined. (authors)

  17. TLD array for precise dose measurements in stereotactic radiation techniques

    International Nuclear Information System (INIS)

    Ertl, A.; Kitz, K.; Griffitt, W.; Hartl, R.F.E.; Zehetmayer, M.

    1996-01-01

    We developed a new TLD array for precise dose measurement and verification of the spatial dose distribution in small radiation targets. It consists of a hemicylindrical, tissue-equivalent rod made of polystyrene with 17 parallel moulds for an exact positioning of each TLD. The spatial resolution of the TLD array was evaluated using the Leskell spherical phantom. Dose planning was performed with KULA 4.4 under stereotactic conditions on axial CT images. In the Leksell gamma unit the TLD array was irradiated with a maximal dose of 10 Gy with an unplugged 14 mm collimator. The doses delivered to the TLDs were rechecked by diode detector and film dosimetry and compared to the computer-generated dose profile. We found excellent agreement of our measured values, even at the critical penumbra decline. For the 14 mm and 18 mm collimator and for the 11 mm collimator combination we compared the measured and calculated data at full width at half maximum. This TLD array may be useful for phantom or tissue model studies on the spatial dose distribution in confined radiation targets as used in stereotactic radiotherapy. (author)

  18. High-temperature absorbed dose measurements in the megagray range

    International Nuclear Information System (INIS)

    Balian, P.; Ardonceau, J.; Zuppiroli, L.

    1988-01-01

    Organic conductors of the tetraselenotetracene family have been tested as ''high-temperature'' absorbed dose dosimeters. They were heated up to 120 0 C and irradiated at this temperature with 1-MeV electrons in order to simulate, in a short time, a much longer γ-ray irradiation. The electric resistance increase of the crystal can be considered a good measurement of the absorbed dose in the range 10 6 Gy to a few 10 8 Gy and presumably one order of magnitude more. This dosimeter also permits on-line (in-situ) measurements of the absorbed dose without removing the sensor from the irradiation site. The respective advantages of organic and inorganic dosimeters at these temperature and dose ranges are also discussed. In this connection, we outline new, but negative, results concerning the possible use of silica as a high-temperature, high-dose dosimeter. (author)

  19. Seed germination of peanuts irradiated with cobalt (60CO)

    International Nuclear Information System (INIS)

    Alves, Niedja Marrize C.; Almeida, Francisco de Assis C.; Gomes, Josivanda P.; Pessoa, Elvira B.; Leal, Artur S. Cavalcanti

    2010-01-01

    This work was realized to evaluate the effect of gamma irradiation ( 60 Co) at doses 0, 0.50, 1.00, 1.50, 2.00, 2.50, 3.00 and 4.00 kGy, on germination of seeds of peanut, cultivar BR1. Irradiation Department of Nuclear, UFPE, where he received after the irradiation, they were stored in packing of PET and polyethylene braided with a time of 90 days. Through the results, obtained monthly, concluded that the dose of 0.5 kGy was effective in the germination of seeds of peanut, not affecting its power of germination and overcoming the witness within 30 to 60 days. (author)

  20. Effect of gamma irradiation on fatty acids of tomato seed oil

    International Nuclear Information System (INIS)

    El-Sayed, S.A.; Raouf, M.S.; Morad, M.M.; Rady, A.H.

    1979-01-01

    Since gamma irradiation of tomatoes is investigated as a tool for increasing tomato shelf-lefe, in this study the tomato seed oil produced from irradiated tomatoes was compared with that produced from industrial tomato seeds and with cotton seeds. Fatty acid contents of tomato seed oil, produced from industrial tomato seed waste and from tomato seeds (Variety Ace), were found nearly the same as in the edible cotton seed oil. Hence, both tomato seed oils may be considered as an additional source of essential fatty acids especially linoleic. Gamma irradiation doses ranged from 50-200 Krad had no significant effect on total saturated and total unsaturated fatty acids. 200 Krad led to significant increases in lenolic acid on the account of insignificant decrease in palmatic acid. Essentail and non essential amino acids of tomato seed meal seem to be equivalent to these of cotton seed meal. This suggests the possible use of tomato seed meal in animal feeding

  1. Safety Assessment of a New Pigmented Safflower Seed Coat (A82 by a Feeding Study on Rat

    Directory of Open Access Journals (Sweden)

    Soraya Karami

    2017-10-01

    Full Text Available ABSTRACT Safflower (Carthamus tinctorius L. is an annual herbaceous plant, cultivated mainly for the seed which is used for edible oil extraction and bird feeding. This study was designed to evaluate the safety of a new pigmented variety of safflower (A82 seeds. The results showed that oral administration of A82 seeds significantly increased the body weight of male rats in a dose-dependent manner (p<0.05. Biochemical tests showed that A82 seeds significantly increased the serum levels of AST (Aspartate aminotransferase (p<0.05, slightly reduced the serum levels of ALT (Alanine aminotransferase and significantly reduced ALP (p<0.05 levels in a dose dependent manner. BUN (Blood Urea Nitrogen and Cr (Creatinine were not significantly changed in A82 seed treated groups. Also, testosterone levels were not significantly changed by administration of different doses of A82. However, Johnson scoring showed slightly decrease in experimental groups. No organ weight or histological changes were observed in liver, kidney, spleen, heart and brain of A82 seed treated animals. These results indicate that A82 seeds have not any toxic effects in Wistar rats. Future studies are required to clarify the exact mechanism by which A82 seeds alter AST levels and body weight in rat.

  2. Clinical application of a OneDose MOSFET for skin dose measurements during internal mammary chain irradiation with high dose rate brachytherapy in carcinoma of the breast.

    Science.gov (United States)

    Kinhikar, Rajesh A; Sharma, Pramod K; Tambe, Chandrashekhar M; Mahantshetty, Umesh M; Sarin, Rajiv; Deshpande, Deepak D; Shrivastava, Shyam K

    2006-07-21

    In our earlier study, we experimentally evaluated the characteristics of a newly designed metal oxide semiconductor field effect transistor (MOSFET) OneDose in-vivo dosimetry system for Ir-192 (380 keV) energy and the results were compared with thermoluminescent dosimeters (TLDs). We have now extended the same study to the clinical application of this MOSFET as an in-vivo dosimetry system. The MOSFET was used during high dose rate brachytherapy (HDRBT) of internal mammary chain (IMC) irradiation for a carcinoma of the breast. The aim of this study was to measure the skin dose during IMC irradiation with a MOSFET and a TLD and compare it with the calculated dose with a treatment planning system (TPS). The skin dose was measured for ten patients. All the patients' treatment was planned on a PLATO treatment planning system. TLD measurements were performed to compare the accuracy of the measured results from the MOSFET. The mean doses measured with the MOSFET and the TLD were identical (0.5392 Gy, 15.85% of the prescribed dose). The mean dose was overestimated by the TPS and was 0.5923 Gy (17.42% of the prescribed dose). The TPS overestimated the skin dose by 9% as verified by the MOSFET and TLD. The MOSFET provides adequate in-vivo dosimetry for HDRBT. Immediate readout after irradiation, small size, permanent storage of dose and ease of use make the MOSFET a viable alternative for TLDs.

  3. The Seed Semipermeable Layer and Its Relation to Seed Quality Assessment in Four Grass Species

    Directory of Open Access Journals (Sweden)

    Yan Y. Lv

    2017-07-01

    Full Text Available The existence of a semipermeable layer in grass seeds has been extensively reported, yet knowledge of its influence on tests for seed viability and vigor that depend upon measurement of electrical conductivity (EC is limited. This study determined the presence and location of the semipermeable layer, and its relation to seed viability and vigor assessment, in seeds of four important grass species-Elymus nutans Griseb., Lolium perenne L., Leymus chinensis (Trin. Tzvel., and Avena sativa L. Intact seeds of E. nutans, Lolium perenne, and Leymus chinensis exhibited little staining with triphenyl tetrazolium chloride (TTC, and there were no differences in EC between seeds with different germination percentage (GP (P > 0.05. After piercing the seed coat, however, all three species displayed positive staining with TTC, along with a significant negative correlation between EC and GP (E. nutans: R2 = 0.7708; Lolium perenne: R2= 0.8414; Leymus chinensis: R2 = 0.859; P < 0.01. In contrast, both intact and pierced seeds of A. sativa possessed a permeable seed coat that showed positive staining with TTC and EC values that were significantly negatively correlated with GP [R2 = 0.9071 (intact and 0.9597 (pierced; P < 0.01]. In commercial seed lots of A. sativa, a field emergence test indicated that EC showed a significant negative correlation with field emergence at two sowing dates (R2= 0.6069, P < 0.01 and 0.5316, P < 0.05. Analysis of seed coat permeability revealed the presence of a semipermeable layer located in the seed coat adjacent to the endosperm in E. nutans, Lolium perenne, and Leymus chinensis; however, no semipermeable layer was observed in A. sativa. This is the first report of the absence of a semipermeable layer in a grass species. The existence of a semipermeable layer is one of the most important factors affecting seed viability and vigor testing (based on EC measurement in E. nutans, Lolium perenne, and Leymus chinensis. Increasing the

  4. Detection and correction of patient movement in prostate brachytherapy seed reconstruction

    Science.gov (United States)

    Lam, Steve T.; Cho, Paul S.; Marks, Robert J., II; Narayanan, Sreeram

    2005-05-01

    Intraoperative dosimetry of prostate brachytherapy can help optimize the dose distribution and potentially improve clinical outcome. Evaluation of dose distribution during the seed implant procedure requires the knowledge of 3D seed coordinates. Fluoroscopy-based seed localization is a viable option. From three x-ray projections obtained at different gantry angles, 3D seed positions can be determined. However, when local anaesthesia is used for prostate brachytherapy, the patient movement during fluoroscopy image capture becomes a practical problem. If uncorrected, the errors introduced by patient motion between image captures would cause seed mismatches. Subsequently, the seed reconstruction algorithm would either fail to reconstruct or yield erroneous results. We have developed an algorithm that permits detection and correction of patient movement that may occur between fluoroscopy image captures. The patient movement is decomposed into translational shifts along the tabletop and rotation about an axis perpendicular to the tabletop. The property of spatial invariance of the co-planar imaging geometry is used for lateral movement correction. Cranio-caudal movement is corrected by analysing the perspective invariance along the x-ray axis. Rotation is estimated by an iterative method. The method can detect and correct for the range of patient movement commonly seen in the clinical environment. The algorithm has been implemented for routine clinical use as the preprocessing step for seed reconstruction.

  5. New design of experiment combined with UV-Vis spectroscopy for extraction and estimation of polyphenols from Basil seeds, Red seeds, Sesame seeds and Ajwan seeds.

    Science.gov (United States)

    Mabood, Fazal; Gilani, Syed Abdullah; Hussain, Javid; Alshidani, Sulaiman; Alghawi, Said; Albroumi, Mohammed; Alameri, Saif; Jabeen, Farah; Hussain, Zahid; Al-Harrasi, Ahmed; Al Abri, Zahra K M; Farooq, Saima; Naureen, Zakira; Hamaed, Ahmad; Rasul Jan, M; Shah, Jasmin

    2017-05-05

    New experimental designs for the extraction of polyphenols from different seeds including Basil seed, Red seed, Sesame seeds and Ajwan seeds were investigated. Four variables the concentration and volume of methanol and NaOH solutions as well as the temperature and time of extraction were varied to see their effect on total phenol extraction. The temperature was varied in the range from 25°C to 200°C while the time in the range from 30 to 200minutes. Response surface methodology was used to optimize the extraction parameters. The estimation of polyphenols was measured through phenols reduction UV-Vis spectroscopic method of phosphotungstic-phosphomolybdic acids (Folin-Ciocalteu's reagent). Calibration curve was made by using tannic acid as a polyphenols standard in the concentration range from 0.1 to 10ppm. The regression line obtained shows the value of correlation coefficient i.e. R=0.930 and Root mean square error of cross validation (RMSEC) value of 0.0654. The Basil seeds were found containing the highest amount of total phenols i.e. 785.76mg/100g. While the Sesame seeds having the least amount i.e. 33.08mg/100g. The Ajwan seeds and the Red seeds are containing the medium amounts i.e. 379mg/100g and 220.54mg/100g respectively. Copyright © 2017 Elsevier B.V. All rights reserved.

  6. New design of experiment combined with UV-Vis spectroscopy for extraction and estimation of polyphenols from Basil seeds, Red seeds, Sesame seeds and Ajwan seeds

    Science.gov (United States)

    Mabood, Fazal; Gilani, Syed Abdullah; Hussain, Javid; Alshidani, Sulaiman; Alghawi, Said; Albroumi, Mohammed; Alameri, Saif; Jabeen, Farah; Hussain, Zahid; Al-Harrasi, Ahmed; Al Abri, Zahra K. M.; Farooq, Saima; Naureen, Zakira; Hamaed, Ahmad; Rasul Jan, M.; Shah, Jasmin

    2017-05-01

    New experimental designs for the extraction of polyphenols from different seeds including Basil seed, Red seed, Sesame seeds and Ajwan seeds were investigated. Four variables the concentration and volume of methanol and NaOH solutions as well as the temperature and time of extraction were varied to see their effect on total phenol extraction. The temperature was varied in the range from 25 °C to 200 °C while the time in the range from 30 to 200 minutes. Response surface methodology was used to optimize the extraction parameters. The estimation of polyphenols was measured through phenols reduction UV-Vis spectroscopic method of phosphotungstic-phosphomolybdic acids (Folin-Ciocalteu's reagent). Calibration curve was made by using tannic acid as a polyphenols standard in the concentration range from 0.1 to 10 ppm. The regression line obtained shows the value of correlation coefficient i.e. R = 0.930 and Root mean square error of cross validation (RMSEC) value of 0.0654. The Basil seeds were found containing the highest amount of total phenols i.e. 785.76 mg/100 g. While the Sesame seeds having the least amount i.e. 33.08 mg/100 g. The Ajwan seeds and the Red seeds are containing the medium amounts i.e. 379 mg/100 g and 220.54 mg/100 g respectively.

  7. SEED INOCULATION WITH Azospirillum brasilense, ASSOCIATED WITH THE USE OF BIOREGULATORS IN MAIZE

    Directory of Open Access Journals (Sweden)

    ALESSANDRO DE LUCCA E BRACCINI

    2012-01-01

    Full Text Available The inoculation of seeds with the bacterium Azospirillum has been carried out in maize culture and other grasses. The application of growth bio-regulators is another technology whose results in maize culture have yet to become more widespread. Current study evaluates the agronomic effectiveness of seed inoculation with Azospirillum brasilense in maize, associated with the use of the growth regulator Stimulate ®. Triple hybrid maize CD 304 underwent the following treatments: 1 - control without nitrogen and without Azospirillum brasilense; 2 - Treatment without nitrogen but with Azospirillum brasilense; 3 - Treatment without nitrogen but with Azospirillum brasilense + Stimulate ®; 4 - Treatment with 50% of nitrogen dose recommended for maize culture; 5 - Treatment with 50% of nitrogen dose and inoculation with Azospirillum brasilense; 6 - Same as 5 but with Stimulate ®; 7 - Total N recommended; 8 - Total N recommended + Azospirillum brasilense ; 9 - Total N recommended + Azospirillum brasilense + Stimulate ®. The inoculation of maize seeds with Azospirillum brasilense increases plant height and grain yield when compared with rates in control. The use of 50% of N dose in sowing, associated with the inoculation of maize seeds with Azospirillum brasilense at 200 mL ha-1 (mixed to the seeds and associated with Stimulate ® (in foliar application, is viable.

  8. Comparison of dose measurements in water versus in air for therapy

    International Nuclear Information System (INIS)

    Nasukha

    1987-01-01

    Comparison of dose measurements in water versus in air for therapy. Dose measurements in water and in the air had been done by teletherapy unit Co-60 Picker Model V 4m/60 with Farmer dosimeter. The result of inverse square law, TAR, PDD, and PSF compared to BJR No. 17 produced a difference of more than 4,65% with SSD 80 cm. Doses in water calculated from the result of dose measurement in air using BJR tables given, was compared with direct dose measurement in water. Values of 0,9850 to 1,0302 were obtained if using inverse square law, PDD and PSF formula. Using inverse square law and TAR, values of 0,9474 to 1,0197 were obtained for 4 depths and 5 field sizes. Measurements done in 5 cm depth and 10 cm x 10 cm field size using both methods, were still good. (author). 7 figs, 8 refs

  9. Biological effects of ion implantation on processing tomato and eggplant seed

    International Nuclear Information System (INIS)

    Mao Peihong; Zeng Xianxian; Jin Xiang

    2004-01-01

    The seed of processing tomato '87-5' (Lycopersicon esculentum Mill) were implanted by the low energy nitrogen ion (N + ) with 6 different doses. The rate of emergence was little reduced in M1 generation, but the fruiting number per plant was increased and it's maturing earlier 20 days than the control. The precocity, disease resistance and stronger growth vigor were shown in M2 generation. Experimental results of two years showed that, according to synthetic analysis in factors such as precocity, disease resistance, high yield and quality, the N + dose of 6 x 10 16 cm -2 (60 times of pulse) for tomato seed '87-5' had been proved to have notable biological effects on M1 and M2 generation. The seed of eggplant 'Wuyeqie' (Solanum melongena L.) was also implanted by the low energy nitrogen ion (N + ) with 2 different doses. Multi-vertical channel fruits were obtained in variable M1 generation, which liked the pomelo without peel. The seed of these variable eggplants was taken and planted in the next year. The meaningful variable fruits, the characters of disease-resistance, purple-peel, small-navel, lantern-form, large-scale, etc. were obtained in beneficial M2 generation. The biggest single-fruit weight reached 1.53 kg, providing valuable germplasm resource for breeding. (authors)

  10. Cosmic-ray contribution in measurement of environmental gamma-ray dose

    International Nuclear Information System (INIS)

    Nagaoka, Kazunori; Honda, Kouichirou; Miyano, Keiji

    1996-01-01

    Nowadays several kinds of dosimeters are being used for environmental gamma-ray monitoring. However the results measured by those instruments are not always in good agreement. It may be caused from the different characteristics of dosimeters. In particular the different responses of the instruments to cosmic-rays give significant influence on the results. Environmental radiation measurements at various altitudes on Mt. Fuji were carried out using a scintillation spectrometer with 3''φ spherical NaI(Tl), a pressurized ionization chamber (PIC), an air-equivalent ionization chamber (IC), thermoluminescence dosimeters (TLD), radiophotoluminescence glass dosimeters (RPLD) and NaI(Tl) scintillation survey meters so that the response characteristics of these instruments to cosmic-rays could be clarified. Cosmic-ray contributions for all instruments were correlated with counting rate over 3 MeV by the spectrometer. Each contribution can be estimated by measurement of the counting rate. Conversion factors (nGy/h/cpm) for IC, PIC, TLD, RPLD and NaI survey meters (TCS166 and TCS121C) were 0.33, 0.32, 0.25, 0.24, 0.06 and -0.01, respectively. Self-doses of these instruments were estimated by measurements at Nokogiriyama facilities of the Institute for Cosmic Ray Research, University of Tokyo. Self-doses for TLD and RPLD were approximately 6 nGy/h. The self dose effect should be taken into consideration in environmental dose measurements. These data are expected to be useful in estimating the cosmic-ray contribution and self-dose in the measurement of environmental gamma-ray dose. (author)

  11. Conventional Treatment of Surface Water Using Moringa Oleifera Seeds Extract as a Primary Coagulant

    Directory of Open Access Journals (Sweden)

    Suleyman A. Muyibi, Ahmed Hissein M Birima, Thamer A. Mohammed

    2012-10-01

    Full Text Available The present study involved the use of a model pilot scale water treatment plant to treat turbid surface water from a stream using processed Moringa oleifera seed with 25 % w/w oil extracted as primary coagulant. The water treatment plant was made up of four unit operations: coagulation, flocculation, sedimentation, and filtration (rapid sand filter. Test runs were carried out for three hours per run over a three-month period with turbidities ranging from 18 to 261 NTU. The turbidity, pH, and alkalinity as well as the filter head loss were measured every 30 minutes during the experimental runs. Average turbidity removal of up to 96 % at an effective doses of 20 and 30 mg/l of oil extracted M. oleifera for low (< 50 NTU and moderate turbidity (< 100 NTU water respectively was observed doses 50 – 80 mg/l for high turbidity (> 100 NTU water. M. oleifera seed extract was found to have no significant effect on pH or alkalinity of the water. The residual turbidities measured during most of the test runs satisfied the Malaysian Guideline for Drinking Water Supplies. Key Words: Moringa oleifera, primary coagulant, coagulation, pilot plant, filtration.

  12. Comparison of measured and calculated doses for narrow MLC defined fields

    International Nuclear Information System (INIS)

    Lydon, J.; Rozenfeld, A.; Lerch, M.

    2002-01-01

    Full text: The introduction of Intensity Modulated Radiotherapy (IMRT) has led to the use of narrow fields in the delivery of radiation doses to patients. Such fields are not well characterized by calculation methods commonly used in radiotherapy treatment planning systems. The accuracy of the dose calculation algorithm must therefore be investigated prior to clinical use. This study looked at symmetrical and asymmetrical 0.1 to 3cm wide fields delivered with a Varian CL2100C 6MV photon beam. Measured doses were compared to doses calculated using Pinnacle, the ADAC radiotherapy treatment planning system. Two high resolution methods of measuring dose were used. A MOSFET detector in a water phantom and radiographic film in a solid water phantom with spatial resolutions of 10 and 89μm respectively. Dose calculations were performed using the collapsed cone convolution algorithm in Pinnacle with a 0.1cm dose calculation grid in the MLC direction. The effect of Pinnacle not taking into account the rounded leaf ends was simulated by offsetting the leaves by 0.1cm in the dose calculation. Agreement between measurement and calculation is good for fields of 1cm and wider. However, fields of less than 1cm width can show a significant difference between measurement and calculation

  13. SU-G-BRB-14: Uncertainty of Radiochromic Film Based Relative Dose Measurements

    Energy Technology Data Exchange (ETDEWEB)

    Devic, S; Tomic, N; DeBlois, F; Seuntjens, J [McGill University, Montreal, QC (Canada); Lewis, D [RCF Consulting, LLC, Monroe, CT (United States); Aldelaijan, S [King Faisal Specialist Hospital & Research Center, Riyadh (Saudi Arabia)

    2016-06-15

    Purpose: Due to inherently non-linear dose response, measurement of relative dose distribution with radiochromic film requires measurement of absolute dose using a calibration curve following previously established reference dosimetry protocol. On the other hand, a functional form that converts the inherently non-linear dose response curve of the radiochromic film dosimetry system into linear one has been proposed recently [Devic et al, Med. Phys. 39 4850–4857 (2012)]. However, there is a question what would be the uncertainty of such measured relative dose. Methods: If the relative dose distribution is determined going through the reference dosimetry system (conversion of the response by using calibration curve into absolute dose) the total uncertainty of such determined relative dose will be calculated by summing in quadrature total uncertainties of doses measured at a given and at the reference point. On the other hand, if the relative dose is determined using linearization method, the new response variable is calculated as ζ=a(netOD)n/ln(netOD). In this case, the total uncertainty in relative dose will be calculated by summing in quadrature uncertainties for a new response function (σζ) for a given and the reference point. Results: Except at very low doses, where the measurement uncertainty dominates, the total relative dose uncertainty is less than 1% for the linear response method as compared to almost 2% uncertainty level for the reference dosimetry method. The result is not surprising having in mind that the total uncertainty of the reference dose method is dominated by the fitting uncertainty, which is mitigated in the case of linearization method. Conclusion: Linearization of the radiochromic film dose response provides a convenient and a more precise method for relative dose measurements as it does not require reference dosimetry and creation of calibration curve. However, the linearity of the newly introduced function must be verified. Dave Lewis

  14. Prototype development or multi-cavity ion chamber for depth dose measurement

    International Nuclear Information System (INIS)

    Nayak, M.K.; Sahu, T.K.; Haridas, G.; Bandyopadhyay, Tapas; Tripathi, R.M.; Nandedkar, R.V.

    2016-01-01

    In high energy electron accelerators, when the electrons interact with vacuum chamber or surrounding structural material, Bremsstrahlung x-rays are produced. It is having a broad spectrum extending up to the electron energies. Dose measured as a function of depth due to electromagnetic cascade will give rise to depth dose curve. To measure the online depth dose profile in an absorber medium, when high energy electron or Bremsstrahlung is incident, a prototype Multi-Cavity Ion Chamber (MCIC) detector is developed. The paper describes the design and development of the MCIC for measurement of depth dose profile

  15. Determination of dosimetric characteristics of OptiSeedTM a plastic brachytherapy 103Pd source

    International Nuclear Information System (INIS)

    Wang Zhonglu; Hertel, Nolan E.

    2005-01-01

    A new 103 Pd plastic brachytherapy source, OptiSeed TM Model 1032P, is being introduced by International Brachytherapy sa (IBt). Measurements of the dose distributions about the source were performed using LiF thermoluminescent dosimeters (TLD-100) in Virtual Water TM . MCNP5 calculations were performed to determine the dose distributions in Virtual Water TM and liquid water. The source dose rate constant, radial dose function, anisotropy function and anisotropy factor have been determined following the updated AAPM TG-43 recommendations. The measured dose rate constant in the Virtual Water TM phantom was determined to be 0.727±6.9% cGy h -1 U -1 , and the computed value is 0.716±2.1% cGy h -1 U -1 . The Monte-Carlo simulation yielded a dose rate constant of 0.665±2.1% cGy h -1 U -1 in water. The measured dose rate constant in water is 0.675±7.5% cGy h -1 U -1 . It is determined by multiplying the dose rate constant measured in the Virtual Water TM phantom with the ratio of the value calculated in water to that in Virtual Water TM . The average of the measured and calculated dose rate constant is 0.670±5.5% cGy h -1 U -1 . The radial dose functions of the new source were measured for distances ranging from 1 to 7 cm in a Virtual Water TM phantom. The anisotropy functions in Virtual Water TM phantom were measured for distances of 2, 3, 5, and 7 cm. The Monte-Carlo computed radial dose functions, anisotropy functions, and anisotropy factors in both Virtual Water TM phantom and water are reported

  16. Dental radiography: tooth enamel EPR dose assessment from Rando phantom measurements

    International Nuclear Information System (INIS)

    Aragno, D.; Fattibene, P.; Onori, S.

    2000-01-01

    Electron paramagnetic resonance dosimetry of tooth enamel is now established as a suitable method for individual dose reconstruction following radiation accidents. The accuracy of the method is limited by some confounding factors, among which is the dose received due to medical x-ray irradiation. In the present paper the EPR response of tooth enamel to endoral examination was experimentally evaluated using an anthropomorphic phantom. The dose to enamel for a single exposure of a typical dental examination performed with a new x-ray generation unit working at 65 kVp gave rise to a CO 2 -signal of intensity similar to that induced by a dose of about 2 mGy of 60 Co. EPR measurements were performed on the entire tooth with no attempt to separate buccal and lingual components. Also the dose to enamel for an orthopantomography exam was estimated. It was derived from TLD measurements as equivalent to 0.2 mGy of 60 Co. In view of application to risk assessment analysis, in the present work the value for the ratio of the reference dose at the phantom surface measured with TLD to the dose at the tooth measured with EPR was determined. (author)

  17. Imaging and Measuring Electron Beam Dose Distributions Using Holographic Interferometry

    DEFF Research Database (Denmark)

    Miller, Arne; McLaughlin, W. L.

    1975-01-01

    Holographic interferometry was used to image and measure ionizing radiation depth-dose and isodose distributions in transparent liquids. Both broad and narrowly collimated electron beams from accelerators (2–10 MeV) provided short irradiation times of 30 ns to 0.6 s. Holographic images...... and measurements of absorbed dose distributions were achieved in liquids of various densities and thermal properties and in water layers thinner than the electron range and with backings of materials of various densities and atomic numbers. The lowest detectable dose in some liquids was of the order of a few k......Rad. The precision limits of the measurement of dose were found to be ±4%. The procedure was simple and the holographic equipment stable and compact, thus allowing experimentation under routine laboratory conditions and limited space....

  18. New approach to explain results of the low dose radiation on the Raphanus sativus

    Energy Technology Data Exchange (ETDEWEB)

    Kurisu, Y.; Yoshioka, K.; Yoshida, S.; Murata, I.; Takahashi, A. [Osaka University, Graduate School of Engineering, Department of Nuclear Engineering, Suita, Osaka (Japan)

    2002-01-01

    Recently, the researches on radiation hormesis toward the animals and plants are made abundantly. The radiation hormesis effect is that subharmful doses of radiation may evoke a stimulatory response in any organism. We did irradiation experiments of fusion (DD and DT) neutron, thermal and fast neutron, and 60-cobalt gamma-ray to the dry seeds of Raphanus stivus, and examined whether radiation hormesis effects appeared by measuring germination rate, the length of a hypocotyl and a root and the total weight on the 7th day from starring cultivation. The evaluation of radiation hormesis effects was done by using relative effectiveness which is the ratio of the mean of the measurement objects of the irradiation group to that of non-irradiation group. In the Raphanus stivus the radiation hormesis effects of the measured objects were only turned up in seed groups irradiated by the fusion (D-T) neutron. We have confirmed that absorbed dose range where the effects are revealed is from 1 cGy to 10 Gy and there the relative effectiveness is from 1.05 to 1.25. In this research the model about radiation hormesis effect on Raphanus sativus confirmed in irradiation of D-T neutrons is proposed. And it is apparent that radiation from radio activated seeds influences hormesis effect on Raphanus sativus. (author)

  19. A simple and reliable method to detect gamma irradiated lentil (Lens culinaris Medik.) seeds by germination efficiency and seedling growth test

    International Nuclear Information System (INIS)

    Chaudhuri, Sadhan K.

    2002-01-01

    Germination efficiency and root/shoot length of germinated seedling is proposed to identify irradiated lentil seeds. Germination percentage was reduced above 0.2 kGy and lentil seeds were unable to germinate above 1.0 kGy dose. The critical dose that prevented the root elongation varied from 0.1 to 0.5 kGy. The sensitivity of lentil seeds to gamma irradiation was inversely proportional to moisture content of the seeds. Radiation effects could be detected in seeds even 12 months storage after gamma irradiation

  20. TREATMENT OF BIODIESEL WASTEWATER USING YELLOW MUSTARD SEEDS

    OpenAIRE

    SAVCI, Serpil

    2017-01-01

    In thisstudy, removal of original biodiesel wastewater (BOD, COD, oil&greas) by yellow mustard seeds was examined bya batch system. The effect of the adsorption time 300 minutes, adsorbent dose(1.0 g/L) and mixing rate (120 rpm) on the adsorption capacity of pollutants.The applicability of the Langmuir and Freundlich isotherms were examined.According to the data obtained from experiments, biodiesel wastewater can betreated by adsorption using yellow mustard seeds.

  1. Oblique incidence of electron beams - comparisons between calculated and measured dose distributions

    International Nuclear Information System (INIS)

    Karcher, J.; Paulsen, F.; Christ, G.

    2005-01-01

    Clinical applications of high-energy electron beams, for example for the irradiation of internal mammary lymph nodes, can lead to oblique incidence of the beams. It is well known that oblique incidence of electron beams can alter the depth dose distribution as well as the specific dose per monitor unit. The dose per monitor unit is the absorbed dose in a point of interest of a beam, which is reached with a specific dose monitor value (DIN 6814-8[5]). Dose distribution and dose per monitor unit at oblique incidence were measured with a small-volume thimble chamber in a water phantom, and compared to both normal incidence and calculations of the Helax TMS 6.1 treatment planning system. At 4 MeV and 60 degrees, the maximum measured dose per monitor unit at oblique incidence was decreased up to 11%, whereas at 18MeV and 60 degrees this was increased up to 15% compared to normal incidence. Comparisons of measured and calculated dose distributions showed that the predicted dose at shallow depths is usually higher than the measured one, whereas it is smaller at depths beyond the depth of maximum dose. On the basis of the results of these comparisons, normalization depths and correction factors for the dose monitor value were suggested to correct the calculations of the dose per monitor unit. (orig.)

  2. Coating with fungicide and different doses of fertilizer in vinhatico ...

    African Journals Online (AJOL)

    Thus, the aim of this study was to evaluate and identify the physical and physiological quality of mahogany seeds that are coated with fertilizer and fungicide. The treatments were: seed coating with sand + lime + fungicide with different doses of fertilizers. The seeds were evaluated in the laboratory and in a greenhouse.

  3. Biochemical and molecular study of genetic stability in tomatoes plants rom seeds treated with low doses of X-ray

    International Nuclear Information System (INIS)

    Ramirez, R; Gonzalez, LM; Chavez, Licet; Camejo, Yanelis; Gonzalez, Maria C; Fernandez, Arais

    2008-01-01

    For the extensive agricultural exploitation of vegetable radio stimulation, it is indispensable to study the genetic stability of treated varieties, having in mind X ray potentialities of inducing not only physiological but genetic changes as well. Therefore, biochemical and molecular markers were employed in tomato plants derived from irradiated seeds at low doses of X rays. For the biochemical analysis, peroxidases, polyphenoloxidases and dismutase superoxide isoenzymes were determined whereas the Random Amplification of Polymorphic DNA (RAPD) method based on Polymerase Chain Reaction (PCR) was used for the molecular analysis. When comparing the electrophoretic patterns from the control and irradiated treatments applied to the three enzymatic systems, there were not appreciable variations on the number of bands and their intensities, indicating the little variability induced in these systems by the low X ray doses. Also, from the molecular viewpoint, electrophoretic patterns showed a clear amplification of DNA by generating a total of 155 bands in all varieties studied. This molecular marker showed a high monomorphism independently of the treatments applied, with values ranging between 86 and 97 %, indicating that irradiation at low doses did not induce an important genetic variability and confirming its possible practical usefulness for stimulating some physiological processes without causing. (Author)

  4. Technical specification of the NRPB thermoluminescent dosemeter used for the measurement of body dose and skin dose

    CERN Document Server

    Shaw, K B

    1977-01-01

    This report specifies the NRPB thermoluminescent dosemeter used for the measurement of radiation dose in tissue at a depth of 700 mg cm sup - sup 2 (body dose) and at a depth of 5-10 mg cm sup - sup 2 (skin dose).

  5. Evaluation of Dacryodes edulis (native pear) seed biomass for Pb (II ...

    African Journals Online (AJOL)

    Dacryodes edulis (Native pear) seed is herein evaluated as a promising biomass for Pb(II) removal from aqueous solution. The Pb(II) adsorption onto Dacryodes edulis seed biomass was influenced by the solution pH, time, biomass dose and initial adsorbate concentration. The Freundlich model fitted better than the ...

  6. Measurement and evaluation of internal dose

    International Nuclear Information System (INIS)

    Lee, Tae Young; Chang, S. Y.; Lee, J. I.; Song, M. Y.

    2006-01-01

    This report describes the contents and results for implementation of internal radiation monitoring programme, measurement of uranium present in lung by lung counter and assessment of committed effective dose for radiation workers of the KNFC. The aim of radiation protection was achieved by implementing this activity

  7. DuraSeal® as a spacer to reduce rectal doses in low-dose rate brachytherapy for prostate cancer

    International Nuclear Information System (INIS)

    Heikkilä, Vesa-Pekka; Kärnä, Aarno; Vaarala, Markku H.

    2014-01-01

    The purpose of this study was to evaluate the utility of off-label use of DuraSeal® polyethylene glycol (PEG) gel in low-dose rate (LDR) prostate brachytherapy seed implantation to reduce rectal doses. Diluted DuraSeal® was easy to use and, in spite of a clearance effect, useful in decreasing D 2cc rectal doses

  8. Rapid Measurement of Neutron Dose Rate for Transport Index

    International Nuclear Information System (INIS)

    Morris, R.L.

    2000-01-01

    A newly available neutron dose equivalent remmeter with improved sensitivity and energy response has been put into service at Rocky Flats Environmental Technology Site (RFETS). This instrument is being used to expedite measurement of the Transport Index and as an ALARA tool to identify locations where slightly elevated neutron dose equivalent rates exist. The meter is capable of measuring dose rates as low as 0.2 μSv per hour (20 μrem per hour). Tests of the angular response and energy response of the instrument are reported. Calculations of the theoretical instrument response made using MCNPtrademark are reported for materials typical of those being shipped

  9. Detection Characteristics of Gamma-Irradiated Seeds by using PSL, TL, ESR and GC/MS

    International Nuclear Information System (INIS)

    Kim, K.H.; Shon, J.H.; Kang, Y.J.; Jo, T.Y.; Park, H.Y.; Kwak, J.Y.; Lee, J.H.; Park, Y.C.; Kim, J.I.; Lee, H.J.; Lee, S.J.; Han, S.B.

    2013-01-01

    In this study, we investigated the applicability of the photostimulated luminescence (PSL), thermoluminescence (TL), electron spin resonance (ESR) and gas chromatography/mass spectrometry (GC/MS) methods for 5 seeds which are not allowed to be irradiated in Korea. All 5 seeds including evening primrose seed, safflower seed, rape seed, sunflower seed and flax seed were analyzed. Samples were irradiated at 1~10 kGy using a 60 Co gamma-ray irradiator. In PSL study, the photon counts of all the unirradiated samples showed negative (lower than 700). The photon counts of irradiated (1, 5, 10 kGy) samples showed positive (higher than 5,000). In TL analysis, results showed that it is possible to apply TL method to all foods containing minerals. In ESR measurements, the ESR signal (single-line) intensity of irradiated foods was higher than non-irradiated foods. The hydrocarbons 1,7-hexadecadiene (C 16:2 ) and 8-heptadecene (C 17:1 ) from oleic acid were detected only in the irradiated samples before and after the treatment at doses ≥ 1 kGy, but they were not detected in non-irradiated samples before and after treatment. These two hydrocarbons could be used as markers to identify irradiated safflower seed, rape seed, Sunflower seed and flax seed. And then, the hydrocarbons 1,7,10-hexadecatriene (C 16:3 ) and 6,9-heptadecadiene (C 17:2 ) from linoleic acid were detected in the evening primrose seed, safflower seed and sunflower seed. According to the results, PSL, TL and GC/ MS methods were successfully applied to detect the irradiated foods. It is concluded that PSL, TL and GC/MS methods are suitable for detection of irradiated samples and a combined method is recommendable for enhancing the reliability of detection results. (author)

  10. Eye lens dosimetry in interventional cardiology: Results of staff dose measurements and link to patient dose levels

    International Nuclear Information System (INIS)

    Antic, V.; Ciraj-Bjelac, O.; Rehani, M.; Aleksandric, S.; Arandjic, D.; Ostojic, M.

    2013-01-01

    Workers involved in interventional cardiology procedures receive high eye lens dose if protection is not used. Currently, there is no suitable method for routine use for the measurement of eye dose. Since most angiography machines are equipped with suitable patient dosemeters, deriving factors linking staff eye doses to the patient doses can be helpful. In this study the patient kerma-area product, cumulative dose at an interventional reference point and eye dose in terms of Hp(3) of the cardiologists, nurses and radiographers for interventional cardiology procedures have been measured. Correlations between the patient dose and the staff eye dose were obtained. The mean eye dose was 121 mSv for the first operator, 33 mSv for the second operator/nurse and 12 mSv for radiographer. Normalised eye lens doses per unit kerma-area product were 0.94 mSv Gy -1 cm -2 for the first operator, 0.33 mSv Gy -1 cm -2 for the second operator/nurse and 0.16 mSv Gy -1 cm -2 for radiographers. Statistical analysis indicated that there is a weak but significant (p < 0.01) correlation between the eye dose and the kerma-area product for all three staff categories. These values are based on a local practice and may provide useful reference for other studies for validation and for wider utilisation in assessing the eye dose using patient dose values. (authors)

  11. Dose measurement, its distribution and individual external dose assessments of inhabitants on high background radiation area in China

    Energy Technology Data Exchange (ETDEWEB)

    Koga, Taeko; Morishima, Hiroshige [Kinki Univ., Atomic Energy Research Institute, Osaka (Japan); Tatsumi, Kusuo [Kinki Univ., Life Science Research Institute, Osaka (Japan); Nakai, Sayaka; Sugahara, Tsutomu [Health Research Foundation, Kyoto (Japan); Yuan Yongling [Labor Hygiene Institute of Hunan Prov. (China); Wei Luxin [Laboratory of Industorial Hygiene, Ministry of Health (China)

    2001-01-01

    As a part of the China-Japan cooperative research on the natural radiation epidemiology, we have carried out a dose-assessment study to evaluate the external to natural radiation in the high background radiation area (HBRA) of Yangjiang in Guangdong province and in the control area (CA) of Enping prefecture since 1991. Because of the difficulties in measuring the individual doses of all inhabitants directly by the personal dosimeters, an indirect method was applied to estimate the exposed dose rates from the environmental radiation dose rates measured by survey meters and the occupancy factors of each hamlet. An individual radiation dose roughly correlates with the environmental radiation dose and the life style of the inhabitant. We have analyzed the environmental radiation doses in the hamlets and the variation of the occupancy factors to obtain the parameters of dose estimation on the inhabitants in selected hamlets; Madi and the several hamlets of the different level doses in HBRA and Hampizai hamlet in CA. With these parameters, we made estimations of individual dose rates and compared them with those obtained from the direct measurement using dosimeters carried by selected individuals. The results obtained are as follows: (1) The environmental radiation dose rates are influenced by the natural radioactive nuclide concentrations in building materials, the age of the building and the arrangement of the houses in a hamlet. There existed a fairly large and heterogeneous distribution of indoor and outdoor environmental radiation. The indoor radiation dose rates were due to the exposure from the natural radioactive nuclides in the building materials and they were about twice higher than the outdoor radiation dose rates. This difference was not observed in CA. (2) The occupancy factor was affected by the age of individuals and the seasons of a year. Indoor occupancy factors were higher for infants and aged individuals than for other age groups. This lead to higher

  12. Dose measurement, its distribution and individual external dose assessments of inhabitants on high background radiation area in China

    International Nuclear Information System (INIS)

    Koga, Taeko; Morishima, Hiroshige; Tatsumi, Kusuo; Nakai, Sayaka; Sugahara, Tsutomu; Yuan Yongling; Wei Luxin

    2001-01-01

    As a part of the China-Japan cooperative research on the natural radiation epidemiology, we have carried out a dose-assessment study to evaluate the external to natural radiation in the high background radiation area (HBRA) of Yangjiang in Guangdong province and in the control area (CA) of Enping prefecture since 1991. Because of the difficulties in measuring the individual doses of all inhabitants directly by the personal dosimeters, an indirect method was applied to estimate the exposed dose rates from the environmental radiation dose rates measured by survey meters and the occupancy factors of each hamlet. An individual radiation dose roughly correlates with the environmental radiation dose and the life style of the inhabitant. We have analyzed the environmental radiation doses in the hamlets and the variation of the occupancy factors to obtain the parameters of dose estimation on the inhabitants in selected hamlets; Madi and the several hamlets of the different level doses in HBRA and Hampizai hamlet in CA. With these parameters, we made estimations of individual dose rates and compared them with those obtained from the direct measurement using dosimeters carried by selected individuals. The results obtained are as follows: 1) The environmental radiation dose rates are influenced by the natural radioactive nuclide concentrations in building materials, the age of the building and the arrangement of the houses in a hamlet. There existed a fairly large and heterogeneous distribution of indoor and outdoor environmental radiation. The indoor radiation dose rates were due to the exposure from the natural radioactive nuclides in the building materials and they were about twice higher than the outdoor radiation dose rates. This difference was not observed in CA. 2) The occupancy factor was affected by the age of individuals and the seasons of a year. Indoor occupancy factors were higher for infants and aged individuals than for other age groups. This lead to higher

  13. Clinical application of a OneDose(TM) MOSFET for skin dose measurements during internal mammary chain irradiation with high dose rate brachytherapy in carcinoma of the breast

    International Nuclear Information System (INIS)

    Kinhikar, Rajesh A; Sharma, Pramod K; Tambe, Chandrashekhar M; Mahantshetty, Umesh M; Sarin, Rajiv; Deshpande, Deepak D; Shrivastava, Shyam K

    2006-01-01

    In our earlier study, we experimentally evaluated the characteristics of a newly designed metal oxide semiconductor field effect transistor (MOSFET) OneDose(TM) in-vivo dosimetry system for Ir-192 (380 keV) energy and the results were compared with thermoluminescent dosimeters (TLDs). We have now extended the same study to the clinical application of this MOSFET as an in-vivo dosimetry system. The MOSFET was used during high dose rate brachytherapy (HDRBT) of internal mammary chain (IMC) irradiation for a carcinoma of the breast. The aim of this study was to measure the skin dose during IMC irradiation with a MOSFET and a TLD and compare it with the calculated dose with a treatment planning system (TPS). The skin dose was measured for ten patients. All the patients' treatment was planned on a PLATO treatment planning system. TLD measurements were performed to compare the accuracy of the measured results from the MOSFET. The mean doses measured with the MOSFET and the TLD were identical (0.5392 Gy, 15.85% of the prescribed dose). The mean dose was overestimated by the TPS and was 0.5923 Gy (17.42% of the prescribed dose). The TPS overestimated the skin dose by 9% as verified by the MOSFET and TLD. The MOSFET provides adequate in-vivo dosimetry for HDRBT. Immediate readout after irradiation, small size, permanent storage of dose and ease of use make the MOSFET a viable alternative for TLDs. (note)

  14. Interspecific variation in persistence of buried weed seeds follows trade-offs among physiological, chemical, and physical seed defenses.

    Science.gov (United States)

    Davis, Adam S; Fu, Xianhui; Schutte, Brian J; Berhow, Mark A; Dalling, James W

    2016-10-01

    Soil seedbanks drive infestations of annual weeds, yet weed management focuses largely on seedling mortality. As weed seedbanks increasingly become reservoirs of herbicide resistance, species-specific seedbank management approaches will be essential to weed control. However, the development of seedbank management strategies can only develop from an understanding of how seed traits affect persistence.We quantified interspecific trade-offs among physiological, chemical, and physical traits of weed seeds and their persistence in the soil seedbank in a common garden study. Seeds of 11 annual weed species were buried in Savoy, IL, from 2007 through 2012. Seedling recruitment was measured weekly and seed viability measured annually. Seed physiological (dormancy), chemical (phenolic compound diversity and concentration; invertebrate toxicity), and physical traits (seed coat mass, thickness, and rupture resistance) were measured.Seed half-life in the soil ( t 0.5 ) showed strong interspecific variation ( F 10,30  = 15, p  central role of seed dormancy in controlling seed persistence.A quantitative comparison between our results and other published work indicated that weed seed dormancy and seedbank persistence are linked across diverse environments and agroecosystems. Moreover, among seedbank-forming early successional plant species, relative investment in chemical and physical seed defense varies with seedbank persistence. Synthesis and applications . Strong covariance among weed seed traits and persistence in the soil seedbank indicates potential for seedbank management practices tailored to specific weed species. In particular, species with high t 0.5 values tend to invest less in chemical defenses. This makes them highly vulnerable to physical harvest weed seed control strategies, with small amounts of damage resulting in their full decay.

  15. Effects of exogenous gamma-aminobutyric acid on α-amylase activity in the aleurone of barley seeds.

    Science.gov (United States)

    Sheng, Yidi; Xiao, Huiyuan; Guo, Chunli; Wu, Hong; Wang, Xiaojing

    2018-03-03

    Gamma-aminobutyric acid (GABA), a nonprotein amino acid, often accumulates in plants exposed to certain environmental stimuli. Previous studies indicated that a closed relationship existed between endogenous GABA and seed germination. However, there are few studies on the effect of exogenous GABA on seed germination. The objective of this study was to explore whether exogenous GABA affected α-amylase activity which the activation is an important stage in seed germination. The level of endogenous GABA in barley seeds rose gradually during germination, suggesting that endogenous GABA was involved in germination. We measured starch degradation under application of various concentration GABA and found that GABA promoted seed starch degradation with a dose-responsive effect. The relationship between GABA and α-amylase activity was investigated by treating barley aleurone with exogenous GABA. The result showed that α-amylase activity began to rise after about 24 h and reached a peak at 48 h. Molecular evidence suggested that GABA increased α-amylase gene expression. We explore the possible roles played by GABA in signal transduction. Copyright © 2018 Elsevier Masson SAS. All rights reserved.

  16. Seed quality in informal seed systems

    NARCIS (Netherlands)

    Biemond, P.C.

    2013-01-01

    Keywords: informal seed systems, seed recycling, seed quality, germination, seed pathology, seed health, seed-borne diseases, mycotoxigenic fungi, Fusarium verticillioides, mycotoxins, Vigna unguiculata, Zea mays, Nigeria.

    Seed is a crucial input for agricultural production.

  17. Lettuce seed germination from plant cultivated with different phosphorus levelsGerminação de sementes de alface obtidas de plantas cultivadas com diferentes doses de fósforo

    Directory of Open Access Journals (Sweden)

    Roberto Lyra Villas Bôas

    2011-07-01

    Full Text Available This study was carried out at São Manuel Experimental Farm, UNESP/FCA, in Botucatu, São Paulo state, Brazil, with the objective to evaluate the lettuce seeds (cultivar Verônica germination from plants cultivated with different phosphorus levels at harvest, in three temperatures and after two conservation period in dry chamber. At seed production stage, the experiment was conducted in randomized complete blocks, with five treatments (0; 200; 400; 600 and 800 kg ha-1 of P2O5 and five replications. After harvesting, seed germination at 20oC and under high temperatures (30 and 33ºC was evaluated. After 15 and 25 months of conservation in dry chamber room it was evaluated germination at 20ºC. The P2O5 levels evaluated did not affect seed germination soon after harvesting at the three temperatures evaluated, but, the higher the temperature, the lower the seed vigor. After 25 months of conservation, the lesser the P2O5 rates, the lesser seed germination and germination speed index.Este trabalho foi conduzido na Fazenda Experimental São Manuel pertencente à UNESP/FCA, Botucatu/SP, com o objetivo de avaliar a germinação de sementes de alface (cultivar Verônica obtidas de plantas cultivadas com diferentes doses de fósforo, logo após a colheita, em três temperaturas e após dois períodos de conservação em câmara seca. O delineamento experimental utilizado foi o de blocos casualizados, com cinco tratamentos (0; 200; 400; 600 e 800 kg ha-1 de P2O5 e cinco repetições. Após a colheita, foram avaliadas a germinação das sementes na temperatura ideal (20ºC e sob altas temperaturas (30 e 33ºC. Após 15 e 25 meses de conservação em câmara seca foi avaliada a germinação a 20ºC. As doses de P2O5 avaliadas não afetaram a germinação das sementes logo após a colheita nas três temperaturas avaliadas, porém, quanto maior a temperatura, menor foi o vigor das sementes. Aos 25 meses após o armazenamento das sementes, quanto menor a dose

  18. LDR brachytherapy: can low dose rate hypersensitivity from the "inverse" dose rate effect cause excessive cell killing to peripherial connective tissues and organs?

    Science.gov (United States)

    Leonard, B E; Lucas, A C

    2009-02-01

    Examined here are the possible effects of the "inverse" dose rate effect (IDRE) on low dose rate (LDR) brachytherapy. The hyper-radiosensitivity and induced radioresistance (HRS/IRR) effect benefits cell killing in radiotherapy, and IDRE and HRS/IRR seem to be generated from the same radioprotective mechanisms. We have computed the IDRE excess cell killing experienced in LDR brachytherapy using permanent seed implants. We conclude, firstly, that IDRE is a dose rate-dependent manifestation of HRS/IRR. Secondly, the presence of HRS/IRR or IDRE in a cell species or tissue must be determined by direct dose-response measurements. Thirdly, a reasonable estimate is that 50-80% of human adjoining connective and organ tissues experience IDRE from permanent implanted LDR brachytherapy. If IDRE occurs for tissues at point A for cervical cancer, the excess cell killing will be about a factor of 3.5-4.0 if the initial dose rate is 50-70 cGy h(-1). It is greater for adjacent tissues at lower dose rates and higher for lower initial dose rates at point A. Finally, higher post-treatment complications are observed in LDR brachytherapy, often for unknown reasons. Some of these are probably a result of IDRE excess cell killing. Measurements of IDRE need be performed for connective and adjacent organ tissues, i.e. bladder, rectum, urinary tract and small bowels. The measured dose rate-dependent dose responses should extended to tissues and organs remain above IDRE thresholds).

  19. Monte Carlo calculation of dosimetric parameters of a {sup 125}I brachytherapy seed encapsulation with biocompatible polymer and a ceramic matrix as radiographic marker

    Energy Technology Data Exchange (ETDEWEB)

    Reis, Lucas P.; Santos, Adriano M.; Grynberg, Suely E., E-mail: lpr@cdtn.b [Centro de Desenvolvimento da Tecnologia Nuclear (CDTN/CNEN-MG), Belo Horizonte, MG (Brazil). Lab. de Dosimetria e Simulacao Computacional; Facure, Alessandro, E-mail: facure@cnen.gov.b [Comissao Nacional de Energia Nuclear (CNEN), Rio de Janeiro, RJ (Brazil)

    2011-07-01

    For prostate cancer treatments, there is an increasing interest in the permanent radioactive seeds implant technique. Currently, in Brazil, the seeds are imported at high prices, which prohibit their use in public hospitals. One of the seed models that have been developed at CDTN has a ceramic matrix as a radioisotope carrier and a radiographic marker; the seed is encapsulated with biocompatible polymer. In this work, Monte Carlo simulations were performed in order to assess the dose distributions generated by the prototype seed model. The obtained data was assessed as described in the TG-43U1 report by the AAPM. The dosimetric parameters dose rate constant, {Lambda}, radial dose function, g{sub L}(r), and anisotropy function, F(r,{theta}), were derived from simulations using the MCNP5 code. The function g(r) shows that the seed has a lower decrease in dose rate on its transverse axis when compared to the 6711 model (one of the most used seeds in permanent prostate implants). F(r,{theta}) shows that CDTN's seed anisotropy curves are smoother than the 6711 model curves for {theta}{<=}20 deg and 0.25{<=}r{<=}1 cm. As well, the {Lambda} value is 15% lower than the {Lambda} value of 6711. The results show that CDTN's seed model can deposit a more isotropic dose. Because of the model's characteristics, the seeds can be impregnated with iodine of lower specific activity which would help reducing costs. (author)

  20. SU-F-T-653: Radiation Exposure from Cs-131 Permanent Seed Implants

    Energy Technology Data Exchange (ETDEWEB)

    Giaddui, T; Hardin, M; To, D; Kremmel, E; Peng, C; Hann, P; Richardson, S; Yu, Y; Harrison, A; Doyle, L [Sidney Kimmel Cancer Center, Thomas Jefferson University, Philadelphia, PA (United States)

    2016-06-15

    Purpose: Permanent seed implants have traditionally been used to treat prostate, lung and head or neck cancers using I-125 and Pd-103. Cs-131, which has higher dose rate is being used to treat brain, head and/or neck cancers in our clinic, therefore, we chose to monitor the dose received by surgeons during the extensive procedure. The aims of this work are to assess the level of radiation exposure to surgeons and the instantaneous exposure at bedside and 1 m from patients. Methods: Ten patients received Cs-131 implants for recurrent brain,head and/or neck cancer; the median implanted activity, number of implanted seeds and prescription dose at 0.5 cm from the perpendicular plane of the implant were: 54.3 mCi (14.52 – 77); 19 (4 – 24) and 60 Gy (range 42 – 60) respectively. Radiation exposure was recorded at bedside and 1 m from the patient using Victoreen ion chamber (Fluke Biomedical, Cleveland, OH). Exposure to surgeons was measured using TLD (Mirion Technologies (GDS), Inc., USA). Results: The median equivalent dose rate at 1 m and bedside immediately following implantation were 1.49×10-2 mSv/h (8.77×10-3–2.63×10-2) and 7.76×10-2 mSv/h (3.1×10-2– 1.53×10-1) respectively. Median equivalent dose to surgeons’ hands was 0.60 mSv (0.33 – 1.48) and no doses were detected for whole-body. Surgical reconstruction for one patient was performed 71 days post-implant and resulted in zero exposure to surgeons. Conclusion: The recorded exposure rates were low when compared with the literature. Post procedure surveys at bed site and 1 m indicated that all patients were within safe limits for discharge (< 0.05 mSv/h at 1 m). However, as a precautionary measure, patients were advised to avoid direct contact with children and pregnant women within four weeks of the implant and stay at least at 3 ft from other people. Surgeons doses were well within occupational dose limits.

  1. Effects of Atmospheric Pressure Air Plasma Pretreatment on the Seed Germination and Early Growth of Andrographis paniculata

    Energy Technology Data Exchange (ETDEWEB)

    Jiayun, Tong; Rui, He; Xiaoli, Zhang; Ruoting, Zhan; Weiwen, Chen [Key Laboratory of Chinese Medicinal Resource from Lingnan (Guangzhou University of Chinese Medicine), Ministry of Education, Guangzhou 510006 (China); Yang Size, E-mail: rayhe618@hotmail.com [Beijing National Laboratory for Condensed Matter Physics, Institute of Physics, Chinese Academy of Sciences, Beijing 100190 (China)

    2014-03-01

    The objective of this paper is to demonstrate whether air plasma can change the seed germination characteristics, seedling emergence, as well as biochemical reactivity, in Andrographis paniculata (A. paniculata) seedlings by modifying the seed coat and finding a beneficial treatment dose. Eight treatment doses and one control were used to conduct electrical conductivity determination, a germination test, a seedling emergence test and a biochemical assay. The results showed that after being treated with air plasma excited at 5950 V for 10 s, the permeability of the seeds was improved significantly, resulting in the acceleration of seed germination and seedling emergence. In the meantime, the catalase activity and catalase isoenzyme expression were also improved, while the malondialdehyde content in the seedlings was decreased (which means greater counteraction with environmental stress). After being treated with 4250 V for 10 s and 5950 V for 20 s, the seed germination was enhanced, but without an obvious change in seedling emergence. However, after treatment with 3400 V for 20 s and 5100 V for 10 s, the permeability of the seeds was decreased, resulting in a delay in seedling emergence. These results indicate that air plasma can change the physiological and biochemical characteristics of Andrographis paniculata seeds by modifying the seed coat, combined with the effects of the active plasma species, and that different treating doses have different effects.

  2. Effects of Atmospheric Pressure Air Plasma Pretreatment on the Seed Germination and Early Growth of Andrographis paniculata

    International Nuclear Information System (INIS)

    Tong Jiayun; He Rui; Zhang Xiaoli; Zhan Ruoting; Chen Weiwen; Yang Size

    2014-01-01

    The objective of this paper is to demonstrate whether air plasma can change the seed germination characteristics, seedling emergence, as well as biochemical reactivity, in Andrographis paniculata (A. paniculata) seedlings by modifying the seed coat and finding a beneficial treatment dose. Eight treatment doses and one control were used to conduct electrical conductivity determination, a germination test, a seedling emergence test and a biochemical assay. The results showed that after being treated with air plasma excited at 5950 V for 10 s, the permeability of the seeds was improved significantly, resulting in the acceleration of seed germination and seedling emergence. In the meantime, the catalase activity and catalase isoenzyme expression were also improved, while the malondialdehyde content in the seedlings was decreased (which means greater counteraction with environmental stress). After being treated with 4250 V for 10 s and 5950 V for 20 s, the seed germination was enhanced, but without an obvious change in seedling emergence. However, after treatment with 3400 V for 20 s and 5100 V for 10 s, the permeability of the seeds was decreased, resulting in a delay in seedling emergence. These results indicate that air plasma can change the physiological and biochemical characteristics of Andrographis paniculata seeds by modifying the seed coat, combined with the effects of the active plasma species, and that different treating doses have different effects

  3. Measurements of gamma-ray dose from a moderated 252Cf source

    International Nuclear Information System (INIS)

    McDonald, J.C.; Griffith, R.V.; Plato, P.; Miklos, J.

    1983-06-01

    The gamma-ray dose fraction from a moderated 252 Cf source was determined by using three types of dosimetry systems. Measurements were carried out in air at a distance of 35 cm from the surface of the moderating sphere (50 cm from the source which is at the center of the sphere) to the geometrical center of each detector. The moderating sphere is 0.8-mm-thick stainless steel shell filled with D 2 O and covered with 0.5 mm of cadmium. Measurements were also carried out with instruments and dosimeters positioned at the surface of a 40 cm x 40 cm x 15 cm plexiglass irradiation phantom whose front surface was also 35 cm from the surface of the moderating sphere. A-150 tissue-equivalent (TE) plastic ionization chambers and a TE proportional counter (TEPC) were used to measure tissue dose, from which the neutron dose equivalent was computed. The ratio of gamma-ray dose to the neutron dose equivalent was determined by using a relatively neutron-insensitive Geiger-Mueller (GM) counter and thermoluminescent dosimeters (TLD). In addition, the event-size spectrum measured by the TEPC was also used to compute the gamma-ray dose fraction. The average value for the ratio of gamma-ray dose to neutron dose equivalent was found to be 0.18 with an uncertainty of about +-18%

  4. Field measurement and interpretation of beta doses and dose rates

    International Nuclear Information System (INIS)

    Selby, J.M.; Swinth, K.L.; Hooker, C.D.; Kenoyer, J.L.

    1983-01-01

    A large number of portable survey instruments employing G.M., ionization chamber, and scintillation detectors used for gamma measurements are also used for monitoring in beta fields by using removable shields to separate the beta and gamma components of the radiation field. The difference does not correspond to an absorbed dose rate for the beta field due to a variety of factors. Among these factors are the dependence on beta energy, source-detector geometries, mixed fields and variable ambient conditions. Attempting to use such measurements directly can lead to errors as high as a factor of 100. Appropriate calibrations and correction factors can be used to reduce the errors in beta measurements to a tolerable level

  5. Effect of X-rays on germination of some wild papilionaceous seeds

    International Nuclear Information System (INIS)

    Chaghtai, S.A.; Khan, S.S.; Sultan, Suman

    1978-01-01

    Dry seeds of Aeschynomene indica Linn., Alysicarpus rugosus, Desmodium gangeticum (Linn.) DC., three species of Indigofera Tephrosia purpurea (Linn.) Pers. and Zorniagibbosa were irradiated with 1500r dose of X-rays for breaking their dormancy. Whereas none of the seeds of Alysicarpus rugosus, Indigo fera enneaphylla, I.linifolia and Zornia gibbosa could germinate. 23%, 10%, 3% and 2% germination was recorded for the seeds of Indigofera hirsuta sansu Baker, Tephrosia purpurea Aeschynomene indica and Desmodium gangeticum respectively. (author)

  6. Prostate brachytherapy postimplant dosimetry: Seed orientation and the impact of dosimetric anisotropy in stranded implants

    International Nuclear Information System (INIS)

    Chng, Nicholas; Spadinger, Ingrid; Rasoda, Rosey; Morris, W. James; Salcudean, Septimiu

    2012-01-01

    Purpose: In postimplant dosimetry for prostate brachytherapy, dose is commonly calculated using the TG-43 1D formalism, because seed orientations are difficult to determine from CT images, the current standard for the procedure. However, the orientation of stranded seeds soon after implantation is predictable, as these seeds tend to maintain their relative spacing, and orient themselves along the implant trajectory. The aim of this study was to develop a method for determining seed orientations from reconstructed strand trajectories, and to use this information to investigate the dosimetric impact of applying the TG-43 2D formalism to clinical postimplant analysis. Methods: Using in-house software, the preplan to postimplant seed correspondence was determined for a cohort of 30 patients during routine day-0 CT-based postimplant dosimetry. All patients were implanted with stranded-seed trains. Spline curves were fit to each set of seeds composing a strand, with the requirement that the distance along the spline between seeds be equal to the seed spacing within the strand. The orientations of the seeds were estimated by the tangents to the spline at each seed centroid. Dose distributions were then determined using the 1D and 2D TG-43 formalisms. These were compared using the TG-137 recommended dose metrics for the prostate, prostatic urethra, and rectum. Results: Seven hundred and sixty one strands were analyzed in total. Defining the z-axis to be cranial-positive and the x-axis to be left-lateral positive in the CT coordinate system, the average seed had an inclination of 21 deg. ± 10 deg. and an azimuth of -81 deg. ± 57 deg. These values correspond to the average strand rising anteriorly from apex to base, approximately parallel to the midsagittal plane. Clinically minor but statistically significant differences in dose metrics were noted. Compared to the 2D calculation, the 1D calculation underestimated prostate V100 by 1.1% and D90 by 2.3 Gy, while

  7. Computational and Experimental Evaluations of a Novel Thermo-Brachytherapy Seed for Treatment of Solid Tumors

    Science.gov (United States)

    Warrell, Gregory R.

    Hyperthermia has long been known as a radiation therapy sensitizer of high potential; however successful delivery of this modality and integrating it with radiation have often proved technically difficult. We present the dual-modality thermobrachytherapy (TB) seed, based on the ubiquitous low dose-rate (LDR) brachytherapy permanent implant, as a simple and effective combination of hyperthermia and radiation therapy. Heat is generated from a ferromagnetic or ferrimagnetic core within the seed, which produces Joule heating by eddy currents. A strategically-selected Curie temperature provides thermal self-regulation. In order to obtain a uniform and sufficiently high temperature distribution, additional hyperthermia-only (HT-only) seeds are proposed to be used in vacant spots within the needles used to implant the TB seeds; this permits a high seed density without the use of additional needles. Experimental and computational studies were done both to optimize the design of the TB and HT-only seeds and to quantitatively assess their ability to heat and irradiate defined, patient-specific targets. Experiments were performed with seed-sized ferromagnetic samples in tissue-mimicking phantoms heated by an industrial induction heater. The magnetic and thermal properties of the seeds were studied computationally in the finite element analysis (FEA) solver COMSOL Multiphysics, modelling realistic patient-specific seed distributions. These distributions were derived from LDR permanent prostate implants previously conducted at our institution; various modifications of the seeds' design were studied. The calculated temperature distributions were analyzed by generating temperature-volume histograms, which were used to quantify coverage and temperature homogeneity for a range of blood perfusion rates, as well as for a range of seed Curie temperatures and thermal power production rates. The impact of the interseed attenuation and scatter (ISA) effect on radiation dose distributions

  8. Investigation of fruit seeds of Cucurbita maxima Duch., in relation to the pre-sowing γ-irradiation and postirradiation temperature effect

    International Nuclear Information System (INIS)

    Goranov, A.I.

    1974-01-01

    Investigations have been made of the seeds (weight, number, and colour) of the fruit of Cucurbita maxima Duch. White Big variety 48/4, obtained from seeds, treated before sowing with γ-rays - 4000 R and 50000 R with dose efficiency 504-630 R min and after irradiation with 80 0 C and 90 0 C/30 min. The colour of the seeds has been determined by the Bondartsev scale (1954). It has been established that the post-irradiation temperature effect of 80 0 and 90 0 C for a period of 3 min probably stimulates the weight of the seeds and the number of the empty seeds and doses have any substantial effect on the process of seed formation. An irradiation dose of 4000 R γ-rays stimulates the weight of the seeds and causes a probable stimulation of the total number of seeds (among them the full seeds) and decreases the percent of the empty seeds. The post-irradiation pre-sowing temperature effect demonstrates a tendency of taking off the stimulation and inhibition effects of the seeds (weight, number and full and empty seeds included). Basic seeds colours are: 06-Atro cremeus, K 3 -Pallido arenicolour, 3 3 -Pallido ochraceus and K 1 -Isabellimus, which include about 75% of the colours. The basic colours are being affected by the temperature and post-irradiation temperature impact and without disappearing, change their percent ratio. (M.Ts.)

  9. Measuring the absorbed dose in critical organs during low rate dose brachytherapy with 137 Cs using thermoluminescent dosemeters

    International Nuclear Information System (INIS)

    Torres, A.; Gonzalez, P.R.; Furetta, C.; Azorin, J.; Andres, U.; Mendez, G.

    2003-01-01

    Intracavitary Brachytherapy is one of the most used methods for the treatment of the cervical-uterine cancer. This treatment consists in the insertion of low rate dose 137 Cs sources into the patient. The most used system for the treatment dose planning is that of Manchester. This planning is based on sources, which are considered fixed during the treatment. However, the experience has shown that, during the treatment, the sources could be displaced from its initial position, changing the dose from that previously prescribed. For this reason, it is necessary to make measurements of the absorbed dose to the surrounding organs (mainly bladder and rectum). This paper presents the results of measuring the absorbed dose using home-made LiF: Mg, Cu, P + Ptfe thermoluminescent dosimeters (TLD). Measurements were carried out in-vivo during 20 minutes at the beginning and at the end of the treatments. Results showed that the absorbed dose to the critical organs vary significantly due to the movement of the patient during the treatment. (Author)

  10. Dosimetric effectiveness in implants with distinct HO166-seed distribution in prostate

    International Nuclear Information System (INIS)

    Braga, Viviane V. B.; Campos, Tarcísio P. R.

    2017-01-01

    Currently, there is a need to produce new therapeutic techniques for the treatment of prostate tumors, considering the high incidence of the disease and significant morbidity rates associated with surgery and radiotherapy. Simulations in brachytherapy produce essential information about the efficiency and dosimetric efficacy compared to other techniques. Computational simulation by Monte Carlo method has been used to evaluate the absorbed dose and effective dose in radiotherapy and radiology. Virtual, analytical or voxelized phantoms are useful in the internal assessment of the spatial distribution of absorbed dose. This study estimated the efficiency of dosimetry by parameters of merit generated from volumetric distributions of absorbed doses simulating various spatial distributions of Ho-166 seeds in a prostate model. A computer model of voxels was developed, using the code SISCODES (Computational System for Dosimetry by Neutrons and Photons by Stochastic Methods applied to radiology and radiotherapy), representative of a real physical simulator predefined as a calibration method. The virtual model reproduced a cubic box, filled with muscle equivalent tissue (TE), where a 5-cm diameter ball with TE-prostate was positioned 2-cm from the air interface. A Ho-166 seed distribution, produced by 16 filet-implants distributed regularly (10-mm pitch) containing 04 separate 8-mm seeds, was employed. Two pitch were considered: 9 and 10 mm, with same distance between seed in a fillet. Based on SISCODE database of chemical composition of tissues and nuclear data, The code allowed the association of nuclear and chemical data to the voxels of the model, by the selection of the tissue of each voxel, as well as the positioning of the sources and their spatial distribution and spectra. The code MCNP5 simulated the transport of photons and electrons in the model, generating the energy deposited per unit mass in each voxel for photons in MeV.g-1 and energy absorbed in MeV for beta

  11. Dosimetric effectiveness in implants with distinct HO166-seed distribution in prostate

    Energy Technology Data Exchange (ETDEWEB)

    Braga, Viviane V. B.; Campos, Tarcísio P. R., E-mail: Vitoriabraga06@gmail.com, E-mail: tprcampos@yahoo.com.br [Universidade Federal de Minas Gerais (UFMG), Belo Horizonte, MG (Brazil). Departamento de Engenharia Nuclear

    2017-07-01

    Currently, there is a need to produce new therapeutic techniques for the treatment of prostate tumors, considering the high incidence of the disease and significant morbidity rates associated with surgery and radiotherapy. Simulations in brachytherapy produce essential information about the efficiency and dosimetric efficacy compared to other techniques. Computational simulation by Monte Carlo method has been used to evaluate the absorbed dose and effective dose in radiotherapy and radiology. Virtual, analytical or voxelized phantoms are useful in the internal assessment of the spatial distribution of absorbed dose. This study estimated the efficiency of dosimetry by parameters of merit generated from volumetric distributions of absorbed doses simulating various spatial distributions of Ho-166 seeds in a prostate model. A computer model of voxels was developed, using the code SISCODES (Computational System for Dosimetry by Neutrons and Photons by Stochastic Methods applied to radiology and radiotherapy), representative of a real physical simulator predefined as a calibration method. The virtual model reproduced a cubic box, filled with muscle equivalent tissue (TE), where a 5-cm diameter ball with TE-prostate was positioned 2-cm from the air interface. A Ho-166 seed distribution, produced by 16 filet-implants distributed regularly (10-mm pitch) containing 04 separate 8-mm seeds, was employed. Two pitch were considered: 9 and 10 mm, with same distance between seed in a fillet. Based on SISCODE database of chemical composition of tissues and nuclear data, The code allowed the association of nuclear and chemical data to the voxels of the model, by the selection of the tissue of each voxel, as well as the positioning of the sources and their spatial distribution and spectra. The code MCNP5 simulated the transport of photons and electrons in the model, generating the energy deposited per unit mass in each voxel for photons in MeV.g-1 and energy absorbed in MeV for beta

  12. Investigation into Hypoglycemic, Antihyperlipidemic, and Renoprotective Potentials of Dennettia tripetala (Pepper Fruit Seed in a Rat Model of Diabetes

    Directory of Open Access Journals (Sweden)

    Innocent Anioke

    2017-01-01

    Full Text Available This study investigated the hypoglycemic, antihyperlipidemic, and renoprotective potentials of Dennettia tripetala (DT in a rat model of diabetes. The hypoglycemic activity in crude methanol seed extract of DT (CMEDT and methanol seed fraction of DT (MFDT measured by glucose oxidase method was increased by 47.37% and 28.72%, respectively, after 8 hours of administration. After 10 days of treatment, CMEDT and MFDT gave a good glycemic control with the highest percentage reduction of 75.82% and 71.34% in glucose level, respectively, which is closely compared with 79.91% in glibenclamide. Using the enzymatic assay and Friedewald’s equation, there was a significant reduction in serum level of total cholesterol (TC, triglyceride (TG, very-low-density lipoprotein (VLDL, and low-density lipoprotein (LDL and a significant increase in high-density lipoprotein (HDL (p<0.05 following treatment with CMEDT and MFDT, when compared with the untreated group, although results varied in dosed groups, with high dose of MFDT showing a better lipid-lowering activity. High dose of MFDT improved lipid metabolism and increased percentage protection against atherogenesis by 44%. However, neither CMEDT nor MFDT ameliorated the renal biochemical alteration in urea and creatinine. Thus, the study demonstrates hypoglycemic and antihyperlipidemic potentials of DT seed in diabetes.

  13. Advances in absorbed dose measurement standards at the australian radiation laboratory

    International Nuclear Information System (INIS)

    Boas, J.F.; Hargrave, N.J.; Huntley, R.B.; Kotler, L.H.; Webb, D.V.; Wise, K.N.

    1996-01-01

    The applications of ionising radiation in the medical and industrial fields require both an accurate knowledge of the amount of ionising radiation absorbed by the medium in question and the capability of relating this to National and International standards. The most useful measure of the amount of radiation is the absorbed dose which is defined as the energy absorbed per unit mass. For radiotherapy, the reference medium is water, even though the measurement of the absorbed dose to water is not straightforward. Two methods are commonly used to provide calibrations in absorbed dose to water. The first is the calibration of the chamber in terms of exposure in a Cobalt-60 beam, followed by the conversion by a protocol into dose to water in this and higher energy beams. The other route is via the use of a graphite calorimeter as a primary standard device, where the conversion from absorbed dose to graphite to absorbed dose in water is performed either by theoretical means making use of cavity ionisation theory, or by experiment where the graphite calorimeter and secondary standard ionisation chamber are placed at scaled distances from the source of the radiation beam (known as the Dose-Ratio method). Extensive measurements have been made at Cobalt-60 at ARL using both the exposure and absorbed dose to graphite routes. Agreement between the ARL measurements and those based on standards maintained by ANSTO and NPL is within ± 0.3%. Absorbed dose measurements have also been performed at ARL with photon beams of nominal energy 16 and 19 MeV obtained from the ARL linac. The validity of the protocols at high photon energies, the validity of the methods used to convert from absorbed dose in graphite to absorbed dose in water and the validity of the indices used to specify the beams are discussed. Brief mention will also be made of the establishment of a calibration facility for neutron monitors at ARL and of progress in the development of ERP dosimetry

  14. Advances in absorbed dose measurement standards at the australian radiation laboratory

    Energy Technology Data Exchange (ETDEWEB)

    Boas, J.F.; Hargrave, N.J.; Huntley, R.B.; Kotler, L.H.; Webb, D.V.; Wise, K.N. [Australian Radiation Laboratory, Yallambie, VIC (Australia)

    1996-12-31

    The applications of ionising radiation in the medical and industrial fields require both an accurate knowledge of the amount of ionising radiation absorbed by the medium in question and the capability of relating this to National and International standards. The most useful measure of the amount of radiation is the absorbed dose which is defined as the energy absorbed per unit mass. For radiotherapy, the reference medium is water, even though the measurement of the absorbed dose to water is not straightforward. Two methods are commonly used to provide calibrations in absorbed dose to water. The first is the calibration of the chamber in terms of exposure in a Cobalt-60 beam, followed by the conversion by a protocol into dose to water in this and higher energy beams. The other route is via the use of a graphite calorimeter as a primary standard device, where the conversion from absorbed dose to graphite to absorbed dose in water is performed either by theoretical means making use of cavity ionisation theory, or by experiment where the graphite calorimeter and secondary standard ionisation chamber are placed at scaled distances from the source of the radiation beam (known as the Dose-Ratio method). Extensive measurements have been made at Cobalt-60 at ARL using both the exposure and absorbed dose to graphite routes. Agreement between the ARL measurements and those based on standards maintained by ANSTO and NPL is within {+-} 0.3%. Absorbed dose measurements have also been performed at ARL with photon beams of nominal energy 16 and 19 MeV obtained from the ARL linac. The validity of the protocols at high photon energies, the validity of the methods used to convert from absorbed dose in graphite to absorbed dose in water and the validity of the indices used to specify the beams are discussed. Brief mention will also be made of the establishment of a calibration facility for neutron monitors at ARL and of progress in the development of ERP dosimetry.

  15. Unit of measurement used and parent medication dosing errors.

    Science.gov (United States)

    Yin, H Shonna; Dreyer, Benard P; Ugboaja, Donna C; Sanchez, Dayana C; Paul, Ian M; Moreira, Hannah A; Rodriguez, Luis; Mendelsohn, Alan L

    2014-08-01

    Adopting the milliliter as the preferred unit of measurement has been suggested as a strategy to improve the clarity of medication instructions; teaspoon and tablespoon units may inadvertently endorse nonstandard kitchen spoon use. We examined the association between unit used and parent medication errors and whether nonstandard instruments mediate this relationship. Cross-sectional analysis of baseline data from a larger study of provider communication and medication errors. English- or Spanish-speaking parents (n = 287) whose children were prescribed liquid medications in 2 emergency departments were enrolled. Medication error defined as: error in knowledge of prescribed dose, error in observed dose measurement (compared to intended or prescribed dose); >20% deviation threshold for error. Multiple logistic regression performed adjusting for parent age, language, country, race/ethnicity, socioeconomic status, education, health literacy (Short Test of Functional Health Literacy in Adults); child age, chronic disease; site. Medication errors were common: 39.4% of parents made an error in measurement of the intended dose, 41.1% made an error in the prescribed dose. Furthermore, 16.7% used a nonstandard instrument. Compared with parents who used milliliter-only, parents who used teaspoon or tablespoon units had twice the odds of making an error with the intended (42.5% vs 27.6%, P = .02; adjusted odds ratio=2.3; 95% confidence interval, 1.2-4.4) and prescribed (45.1% vs 31.4%, P = .04; adjusted odds ratio=1.9; 95% confidence interval, 1.03-3.5) dose; associations greater for parents with low health literacy and non-English speakers. Nonstandard instrument use partially mediated teaspoon and tablespoon-associated measurement errors. Findings support a milliliter-only standard to reduce medication errors. Copyright © 2014 by the American Academy of Pediatrics.

  16. Estimation of Electron Dose Delivered by a 0.4 MeV Accelerator from Bremsstrahlung Dose Measurements

    DEFF Research Database (Denmark)

    Karadjov, A. G.; Hansen, Jørgen-Walther

    1980-01-01

    Determination of a 0.4 MeV electron dose from a bremsstrahlung dose measurement using a converter-detector system is considered. The detector used is a Frickle dosimeter, and the converters are aluminum, copper and lead foils. Optimal converter thickness is ascertained experimentally for each mat...... materials within a Z-range of 13–82. A linear relation is found between bremsstrahlung dose and electron dose ranging from 2 to 20 Mrad. Finally the effect of converter area on detector response is studied....

  17. Low doses of ionizing radiation and hydrogen peroxide stimulate plant growth

    International Nuclear Information System (INIS)

    Korystov, Y.; Narimanov, A.

    1997-01-01

    The present study shows that low-dose oxidative stress induced by ionizing radiation (10-20 cGy) and hydrogen peroxide (1-100 pmol per litre) stimulates germination of seeds and growth of sprouts and roots. The growth of seedlings can be stimulated by treatment of seeds as well as seedlings but in the latter case it needs lower doses. The stimulation effect is observed in a narrow dose interval which is the same for the plant species studied: barley, wheat, pea, maize and melon

  18. Measuring dose from radiotherapy treatments in the vicinity of a cardiac pacemaker.

    Science.gov (United States)

    Peet, Samuel C; Wilks, Rachael; Kairn, Tanya; Crowe, Scott B

    2016-12-01

    This study investigated the dose absorbed by tissues surrounding artificial cardiac pacemakers during external beam radiotherapy procedures. The usefulness of out-of-field reference data, treatment planning systems, and skin dose measurements to estimate the dose in the vicinity of a pacemaker was also examined. Measurements were performed by installing a pacemaker onto an anthropomorphic phantom, and using radiochromic film and optically stimulated luminescence dosimeters to measure the dose in the vicinity of the device during the delivery of square fields and clinical treatment plans. It was found that the dose delivered in the vicinity of the cardiac device was unevenly distributed both laterally and anteroposteriorly. As the device was moved distally from the square field, the dose dropped exponentially, in line with out-of-field reference data in the literature. Treatment planning systems were found to substantially underestimate the dose for volumetric modulated arc therapy, helical tomotherapy, and 3D conformal treatments. The skin dose was observed to be either greater or lesser than the dose received at the depth of the device, depending on the treatment site, and so care should be if skin dose measurements are to be used to estimate the dose to a pacemaker. Square field reference data may be used as an upper estimate of absorbed dose per monitor unit in the vicinity of a cardiac device for complex treatments involving multiple gantry angles. Copyright © 2016 Associazione Italiana di Fisica Medica. Published by Elsevier Ltd. All rights reserved.

  19. Measurements of dose with individual FAMOS transistors

    Energy Technology Data Exchange (ETDEWEB)

    Scheick, L.Z.; McNulty, P.J.; Roth, D.R.; Davis, M.G.; Mason, B.E.

    1999-12-01

    A new method is described for measuring the doses absorbed by microstructures from an exposure to ionizing radiation. The decrease in the duration of UltraViolet light (UV) exposure required to erase each cell of a commercial UltraViolet erasable Programmable Read Only Memory (UVPROM) correlates with the dose absorbed by the floating gate of that transistor. This technique facilitates analysis of the microdose distribution across the array and the occurrence of Single Event Upset (SEU) like anomalous shifts due to rare large energy-deposition events.

  20. Measurements of dose with individual FAMOS transistors

    International Nuclear Information System (INIS)

    Scheick, L.Z.; McNulty, P.J.; Roth, D.R.; Davis, M.G.; Mason, B.E.

    1999-01-01

    A new method is described for measuring the doses absorbed by microstructures from an exposure to ionizing radiation. The decrease in the duration of UltraViolet light (UV) exposure required to erase each cell of a commercial UltraViolet erasable Programmable Read Only Memory (UVPROM) correlates with the dose absorbed by the floating gate of that transistor. This technique facilitates analysis of the microdose distribution across the array and the occurrence of Single Event Upset (SEU) like anomalous shifts due to rare large energy-deposition events

  1. Time dependence of the yield of chromosome mutations and free radicals in. gamma. -irradiated dry seeds

    Energy Technology Data Exchange (ETDEWEB)

    Nuzhdin, N I; Samokhvalova, N S; Dozortseva, R L; Petrova, L E; Sheksheev, E M [AN SSSR, Moscow. Inst. Ehvolyutsionnoj Morfologii i Ehkologii Zhivotnykh

    1976-07-01

    It has been revealed in dry barley seeds that the yield of induced ESR signals and the number of cells having chromosome aberrations depend on the irradiation conditions (single or fractionated exposures, and varying dose rates) and the duration of the post-irradiation storage. Radiobiological effects caused in dry seeds by fractionated irradiation and varying dose rates are of different nature.

  2. TREATMENT OF SLAUGHTERHOUSE WASTEWATER USING Moringa oleifera LAM SEEDS AS COAGULANT

    Directory of Open Access Journals (Sweden)

    Facundo Dagoberto Morales Avelino

    2009-02-01

    Full Text Available Both the solution and the suspension of grinded and soaked seeds of Moringa oleifera Lam, were used in order to reduce the absorbance (turbidity of wastewater from a slaughterhouse. The minimum reaction time obtained was 5 minutes with an absorbancy reduction of 25% for wastewater from the septic tank, and 82% of absorbancy reduction for the wastewater from the pond. In relation to the coagulant dose (seeds suspension, although 25 g/l was more efficient (up to 78% of absorbancy reduction, it was no significative different to the dose of 10 g/l which reached an absorbance removal of 61%.

  3. [Seed quality test methods of Paeonia suffruticosa].

    Science.gov (United States)

    Cao, Ya-Yue; Zhu, Zai-Biao; Guo, Qiao-Sheng; Liu, Li; Wang, Chang-Lin

    2014-11-01

    In order to optimize the testing methods for Paeonia suffruticosa seed quality, and provide basis for establishing seed testing rules and seed quality standard of P. suffruticosa. The seed quality of P. suffruticosa from different producing areas was measured based on the related seed testing regulations. The seed testing methods for quality items of P. suffruticosa was established preliminarily. The samples weight of P. suffruticosa was at least 7 000 g for purity analysis and was at least 700 g for test. The phenotypic observation and size measurement were used for authenticity testing. The 1 000-seed weight was determined by 100-seed method, and the water content was carried out by low temperature drying method (10 hours). After soaking in distilled water for 24 h, the seeds was treated with different temperature stratifications of day and night (25 degrees C/20 degrees C, day/night) in the dark for 60 d. After soaking in the liquor of GA3 300 mg x L(-1) for 24 h, the P. suffruticos seeds were cultured in wet sand at 15 degrees C for 12-60 days for germination testing. Seed viability was tested by TlC method.

  4. Trend of collective dose and dose reduction measures of Mitsubishi Electric Corporation workers in nuclear power plants

    International Nuclear Information System (INIS)

    Yamato, I.; Nakayama, T.; Shimokawa, F.; Yamamoto, T.

    1996-01-01

    MELCO has supplied the reactor instrumentation control system, reactor coolant pump motors, turbine generator and central control system for the pressurized water type nuclear power plant. For the legal periodical inspection and repair work, MELCO has also received orders for the periodical inspection for 23 power plants (including 4 plants under construction) of 5 electric power companies, and executed the inspection work from the view point of preventive maintenance. The annual dose for MELCO's workers is liable to be decreased in spite of increased number of plants. The dose for new plant in particular is 50, or less as compared with that for conventional plant. This is because the measures taken for the conventional plant against the dose reduction is reflected upon the new plant. The dose reduction measures are taken for each system for which order was received. Such measures are mainly intended to improve the work procedures and equipment for reduction of work time in the radioactive area and to arrange the working process, so as to perform the work in such period when the dose level at the working environment is low. To enhance the workers' consciousness for reduction of dose, MELCO provided the workers with dose predictive training, and let them aware of such items known at the tool box briefing (TBX), which could realize the dose reduction for workers. MELCO has been positively promoting the activity to arrange the desirable work environment for extermination of 3Ks (giken, gitsui, titanai) or 3Ds (dangerous, difficult, dirty) including protection against radiation in corporation with electric power companies. (author)

  5. Dose measurement, its distribution and individual external dose assessments of inhabitants in the high background radiation areas in China

    International Nuclear Information System (INIS)

    Morishima, Hiroshige; Koga, Taeko; Tatsumi, Kusuo; Nakai, Sayaka; Sugahara, Tsutomu; Yuan Yongling; Wei Luxin

    2000-01-01

    As a part of the China-Japan cooperative research on natural radiation epidemiology, we have carried out a dose-assessment study to evaluate the external exposure to natural radiation in the high background radiation areas (HBRA) of Yangjiang in Guangdong province and in the control areas (CA) of Enping prefecture since 1991. Because of the difficulties in measuring the individual doses of all inhabitants directly by personal dosimeters, an indirect method was applied in which the exposed individual doses were estimated from the environmental radiation doses measured by survey meters and the occupancy factors of each hamlet. We analyzed the dose in the hamlets and the variation in the occupancy factors to obtain the parameters of dose estimation on the inhabitants in selected hamlets; Madi and several hamlets of different dose levels in HBRA and Hampizai hamlet in CA. With these parameters, we estimated individual dose rates and compared them with those obtained from direct measurement using dosimeters carried by selected individuals. The results obtained are as follows. The environmental radiation doses are influenced by the natural radioactive nuclide concentrations in building materials, the age of the building and the arrangement of the houses in a hamlet. There existed a fairly large and heterogeneous distribution of indoor and outdoor environmental radiations. The indoor radiation doses were due to exposure from the natural radioactive nuclides in the building materials and were about two times as large as the outdoor radiation doses. The difference between indoor and outdoor doses was not observed in CA. The occupancy factor was influenced by the age of individuals and by the season of the year. The occupancy factor was higher for infants and aged individuals than for other age groups. This lead to higher dose rates of exposure to those age groups. A good correlation was observed between the dose assessed indirectly and that measured directly and the

  6. Dose measurement, its distribution and individual external dose assessments of inhabitants in the high background radiation areas in China

    Energy Technology Data Exchange (ETDEWEB)

    Morishima, Hiroshige; Koga, Taeko [Kinki Univ., Higashi-Osaka, Osaka (Japan). Atomic Energy Research Inst.; Tatsumi, Kusuo; Nakai, Sayaka; Sugahara, Tsutomu; Yuan Yongling; Wei Luxin

    2000-10-01

    As a part of the China-Japan cooperative research on natural radiation epidemiology, we have carried out a dose-assessment study to evaluate the external exposure to natural radiation in the high background radiation areas (HBRA) of Yangjiang in Guangdong province and in the control areas (CA) of Enping prefecture since 1991. Because of the difficulties in measuring the individual doses of all inhabitants directly by personal dosimeters, an indirect method was applied in which the exposed individual doses were estimated from the environmental radiation doses measured by survey meters and the occupancy factors of each hamlet. We analyzed the dose in the hamlets and the variation in the occupancy factors to obtain the parameters of dose estimation on the inhabitants in selected hamlets; Madi and several hamlets of different dose levels in HBRA and Hampizai hamlet in CA. With these parameters, we estimated individual dose rates and compared them with those obtained from direct measurement using dosimeters carried by selected individuals. The results obtained are as follows. The environmental radiation doses are influenced by the natural radioactive nuclide concentrations in building materials, the age of the building and the arrangement of the houses in a hamlet. There existed a fairly large and heterogeneous distribution of indoor and outdoor environmental radiations. The indoor radiation doses were due to exposure from the natural radioactive nuclides in the building materials and were about two times as large as the outdoor radiation doses. The difference between indoor and outdoor doses was not observed in CA. The occupancy factor was influenced by the age of individuals and by the season of the year. The occupancy factor was higher for infants and aged individuals than for other age groups. This lead to higher dose rates of exposure to those age groups. A good correlation was observed between the dose assessed indirectly and that measured directly and the

  7. Measurement of radiation dose with a PC-based instrument

    International Nuclear Information System (INIS)

    Jangland, L.; Neubeck, R.

    1994-01-01

    The purpose of this study was to investigate in what way the introduction of Digital Subtraction Angiography has influenced absorbed doses to the patient and personnel. Calculation of the energy imparted to the patient, ε, was based on measurements of the dose-area product, tube potential and tube current which were registered with a PC-based instrument. The absorbed doses to the personnel were measured with TLD. The measurements on the personnel were made only at the digital system. The results indicate large variations in ε between different types of angiographic examinations of the same type. The total ε were similar on both systems, although the relative contribution from image acquisition and fluoroscopy were different. At the conventional system fluoroscopy and image acquisition contributed almost equally to the total ε. At the digital system 25% of the total ε was due to fluoroscopy and 75% to image acquisition. The differences were due to longer fluoroscopic times on the conventional system, mainly due to lack of image memory and road mapping, and lower ε/image, due to lower dose settings to the film changer compared to the image intensifier on the digital system. 11 refs., 8 figs., 9 tabs

  8. Dosimetric study of permanent prostate brachytherapy utilizing 131Cs, 125I and 103Pd seeds

    International Nuclear Information System (INIS)

    Yang Ruijie; Wang Junjie; Zhang Hongzhi

    2009-01-01

    Objective: To compare the dosimetric differences of permanent prostate brachytherapy utilizing 131 Cs, 125 I and 103 Pd seeds. Methods: Twenty-five patients with T 1 -T 2 c prostate cancer who had previously implanted with 125 I seeds were randomly selected in our study. The patients were re-planned with 131 Cs, 125 I and 103 Pd seeds by using the Prowess Brachytherapy 3.1 planning system to the prescription doses of 115 Gy, 145 Gy and 125 Gy, respectively. The seed strengths were 1.8 U,0.5 U and 1.8 U, respectively. The prostate, prostatic urethra and anterior wall of the rectum were contoured on trans-rectal ultrasound images. PTV was outlined based on the prostate volume with no margin applied. The attempted planning goals were that V 100 (the percentage volume of the prostate receiving at least 100% of the prescription doses)= 95%, D 90 (the minimum percentage dose covering 90% of the prostate volume) ≥100%, and prostatic urethra UD 10 (the maximum percentage dose receiving by 10% of the contoured urethra) ≤150%. For the plan comparison, we also computed prostate V 150 , prostatic urethra UV 120 , rectum RV 100 , and the number of implanted seeds and needles. The significance of the differences was tested using one way analysis of variance. Results: The average V 200 in the 103 Pd, 125 I and 131 Cs plans were 28.7%, 20.9% and 19.6% (F=42.50, P=0.000); the average V 150 were 51.9%, 42.1% and 39.4% (F=26.15, P=0.000); the average UV 120 were 26.9%, 29.5% and 23.8% (F=0.37, P=0.691); and the average rectum RV 100 were 0.31 cm 3 , 0.22 cm 3 and 0.19 cm 3 (F=0.43, P=0.652). For 103 Pd, 125 I and 131 Cs, the average number of implanted seeds per cm 3 prostate were 2.02, 2.01 and 1.87 (F=1.92, P=0.154), and the average number of needles were 33.6, 32.9 and 31.6 (F=0.26,P=0.772). Conclusions: Comparing to 125 I and 103 Pd seeds used in permanent prostate brachytherapy, 131 Cs seeds has better dose homogeneity, and possible better sparing of the urethra and rectum

  9. Dose reduction in LDR brachytherapy by implanted prostate gold fiducial markers.

    Science.gov (United States)

    Landry, Guillaume; Reniers, Brigitte; Lutgens, Ludy; Murrer, Lars; Afsharpour, Hossein; de Haas-Kock, Danielle; Visser, Peter; van Gils, Francis; Verhaegen, Frank

    2012-03-01

    The dosimetric impact of gold fiducial markers (FM) implanted prior to external beam radiotherapy of prostate cancer on low dose rate (LDR) brachytherapy seed implants performed in the context of combined therapy was investigated. A virtual water phantom was designed containing a single FM. Single and multi source scenarios were investigated by performing Monte Carlo dose calculations, along with the influence of varying orientation and distance of the FM with respect to the sources. Three prostate cancer patients treated with LDR brachytherapy for a recurrence following external beam radiotherapy with implanted FM were studied as surrogate cases to combined therapy. FM and brachytherapy seeds were identified on post implant CT scans and Monte Carlo dose calculations were performed with and without FM. The dosimetric impact of the FM was evaluated by quantifying the amplitude of dose shadows and the volume of cold spots. D(90) was reported based on the post implant CT prostate contour. Large shadows are observed in the single source-FM scenarios. As expected from geometric considerations, the shadows are dependent on source-FM distance and orientation. Large dose reductions are observed at the distal side of FM, while at the proximal side a dose enhancement is observed. In multisource scenarios, the importance of shadows appears mitigated, although FM at the periphery of the seed distribution caused underdosage (LDR brachytherapy seed implant dose distributions. Therefore, reduced tumor control could be expected from FM implanted in tumors, although our results are too limited to draw conclusions regarding clinical significance.

  10. Seed inoculation with Azospirillum brasilense and N fertilization of corn in the Cerrado biome

    Directory of Open Access Journals (Sweden)

    Ana Carolina Pereira de Vasconcelos

    Full Text Available ABSTRACT There is a great interest to reduce doses and increase efficiency of inputs in agriculture. One alternative to lower doses of N fertilizers in corn is seed inoculation with diazotrophic bacteria, which can fix atmospheric N in soil. This study aimed to evaluate the effect of N doses-in the absence and presence of Azospirillum brasilense-on plant nutritional status at different growth stages and on seed yield of corn. The experiment was conducted during the 2011/2012 production season on a typical cerrado soil in Uberlândia, Triângulo Mineiro. The experimental design was randomized blocks with six repetitions. The treatments consisted of five N doses and the absence or presence of Azospirillum brasilense (100 mL ha-1 as a seed inoculant. A commercial product with minimum concentration of 2x108 CFU mL-1 100 mL ha-1 was used. Inoculation with Azospirillum brasilense did not significantly affect corn macronutrient content and yield, except for foliar calcium and potassium at 200 kg N ha-1 at the V8 stage. Corn yield increased with N doses up to 150 kg N ha-1.

  11. Bulk YBCO seeded with 45°–45° bridge-seeds of different lengths

    International Nuclear Information System (INIS)

    Shi, Y-H; Durrell, J H; Dennis, A R; Cardwell, D A

    2013-01-01

    Single grain, (RE)BCO (rare earth–barium–copper oxide) bulk superconductors in large or complicated geometries are required for a variety of potential applications, such as in motors and generators and magnetic shielding devices. As a result, top, multi-seeded, melt growth has been investigated over the past 15 years in an attempt to enlarge the size of (RE)BCO single grains specifically for such applications. Of these multi-seeding techniques, so-called bridge-seeding provides the best alignment of two seeds in a single grain growth process. Here we report, for the first time, the successful growth of YBCO (yttrium–barium–copper oxide) using a special, 45°–45°, arrangement of bridge-seeds. The superconducting properties, including trapped field, of the multi-seeded YBCO grains have been measured for different bridge lengths of the 45°–45° bridge-seeds. The boundaries at the impinging growth front and the growth features of the top, multi-seeded surface and cross-section of the multi-seeded, samples have been analysed using optical microscopy. The results suggest that an impurity-free boundary between the two seeds of each leg of the bridge-seed can form when 45°–45° bridge-seeds are used to enlarge the size of YBCO grains. (paper)

  12. The antiproton depth–dose curve measured with alanine detectors

    CERN Document Server

    Bassler, Niels; Palmans, Hugo; Holzscheiter, Michael H; Kovacevic, Sandra

    2008-01-01

    n this paper we report on the measurement of the antiproton depth–dose curve, with alanine detectors. The results are compared with simulations using the particle energy spectrum calculated by FLUKA, and using the track structure model of Hansen and Olsen for conversion of calculated dose into response. A good agreement is observed between the measured and calculated relative effectiveness although an underestimation of the measured values beyond the Bragg-peak remains unexplained. The model prediction of response of alanine towards heavy charged particles encourages future use of the alanine detectors for dosimetry of mixed radiation fields.

  13. Breast internal dose measurements in a physical thoracic phantom

    Energy Technology Data Exchange (ETDEWEB)

    Silva, S.D.; Oliveira, M.A.; Castro, A.L.S.; Dias, H.G.; Nogueira, L.B.; Campos, T.P.R., E-mail: sadonatosilva@hotmail.com [Universidade Federal de Minas Gerais (UFMG), Belo Horizonte, MG (Brazil). Departamento de Engenharia Nuclear; Hospital das Clinicas de Uberlandia, MG (Brazil). Departamento de Oncologia; Universidade Federal de Minas Gerais (UFMG), Belo Horizonte, MG (Brazil). Anatomia e Departamento de Imagem

    2017-10-01

    Radiotherapy is a cancer treatment intended to deposit the entire prescribed dose homogeneously into a target volume in order to eliminate the tumor and to spare the surrounding healthy tissues. This paper aimed to provide a dosimetric comparison between the treatment planning system (TPS) ECLIPSE from Varian Medical Systems and the internal dosimetric measurements in a breast phantom. The methodology consisted in performing a 3D conformal radiotherapy planning with two tangential opposite parallel fields applied to the synthetic breast in a thoracic phantom. The irradiation was reproduced in the Varian Linear accelerator, model SL - 20 Precise, 6 MV energy. EBT2 Radiochromic films, placed into the glandular equivalent tissue of the breast, were used to measure the spatial dose distribution. The absorbed dose was compared to those values predicted by the treatment planning system; besides, the dosimetric uncertainties were analyzed. The modal absorbed dose was in agreement with the prescribed value of 180 cGy, although few high dose points between 180 and 220 cGy were detected. The findings suggested a non-uniform dose distribution in the glandular tissue of the synthetic breast, similar to those found in the TPS, associated with the irregular anatomic breast shape and presence of inhomogeneities next to the thoracic wall generated by the low lung density. (author)

  14. Seed regulations and local seed systems

    NARCIS (Netherlands)

    Louwaars, N.

    2000-01-01

    Seed regulations have been introduced in most countries based on the development of formal seed production. Concerns about seed quality and about the varietal identity of the seeds have commonly led to seed laws. However, formal regulations are often inappropriate for informal seed systems, which

  15. Antioxidant activity of extract from gamma irradiated grape (Psidium guajava L.) seeds

    International Nuclear Information System (INIS)

    Abdeldaiem, M. H.; Ali, H.G.M.; Nasr, E.H.

    2012-01-01

    The objective this study was to study the antioxidant activity efficiency of extracts from irradiated defatted guava (Psidium guajava L.) seeds at dose levels of 0, 2, 4 and 6 kGy. The non-irradiated and irradiated defatted guava seeds samples were extracted with acetone: water: acetic acid (90:9.5:0.5). Immediately after irradiation, the antioxidant activity was studied. Gas chromatographic-Mass spectrum was applied to identify and quantify the constituents (%) of extracts and the amino acids composition was determined in all samples under investigation of defatted guava seeds powder. The measurements of the antioxidant activity, using a γ-carotene-linoleate model system and radical scavenging capacity effect on 2, 2-diphenyl-1- picrylhydrazyl (DPPH) radical, was determined in the extracts of non-irradiated and irradiated defatted guava seeds powder. Meanwhile, noodles (homemade strips macaroni) were prepared from blends of 72% wheat flour containing 0, 2.5, 5 and 7.5% levels of non-irradiated defatted guava seeds powder. The results showed that samples of extracts from non-irradiated and irradiated defatted guava seeds had contained a considerable total polyphenolic compounds and marked scavenging activity on DPHH radical. On the other hand , the gas chromatography (GC) and mass spectroscopy (MS) separation technique led to identification of 26 components the of extract non-irradiated and irradiated samples. Also, the data revealed that guava seeds powder samples under investigation passes the most important essential amino acids and for human health such as trace elements iron, zinc and manganese. Noodles prepared from 2.5% level of guava seeds powder-wheat flour blend had high acceptable quality. Thus, guava seeds, a waste from guava industry can be utilized improved nutritional properties of noodles or used its extracts as natural antioxidant in food industry field

  16. Peripheral dose measurement for CyberKnife radiosurgery with upgraded linac shielding

    International Nuclear Information System (INIS)

    Chuang, Cynthia F.; Larson, David A.; Zytkovicz, Andrea; Smith, Vernon; Petti, Paula L.

    2008-01-01

    The authors investigated the peripheral dose reduction for CyberKnife radiosurgery treatments after the installation of a linac shielding upgrade. As in a previous investigation, the authors considered two treatment plans, one for a hypothetical target in the brain and another for a target in the thorax, delivered to an anthropomorphic phantom. The results of the prior investigation showed that the CyberKnife delivered significantly higher peripheral doses than comparable model C Gamma Knife or IMRT treatments. Current measurements, after the linac shielding upgrade, demonstrate that the additional shielding decreased the peripheral dose, expressed as a percentage of the delivered monitor units (MU), by a maximum of 59%. The dose reduction was greatest for cranial-caudal distances from the field edge less than 30 cm, and at these distances, the CyberKnife peripheral dose, expressed as a percentage of the delivered MU, is now comparable to that measured for the other treatment modalities in our previous investigation. For distances between 30 and 70 cm from the field edge, the additional shielding reduced the peripheral dose by between 20% and 55%. At these distances, the CyberKnife peripheral dose remains higher than doses measured in our previous study for the model C Gamma Knife and IMRT

  17. Ambient dose measurement in some CT departments in Khartoum State

    International Nuclear Information System (INIS)

    Mohammed, S. A. H.

    2012-09-01

    Computerized Tomography (CT) is now one of the most important radiological examinations world wide.The frequency of CT examinations is increasing rapidly from 2% of all radiological examinations in some countries a decade age to 10-15% now. During the imaging procedure, staff may expose to a significant dose. Therefore, ambient dose measurement is important in the shortage of regular personal monitoring in sudan. This study intended to evaluate the ambient dose at some CT departments (Medical Military hospital, Alamal National Hospital, Elnelin Diagnostic Center and Modern Medical Centre). These departments were equipped with daul, 16 and 64 multi detector CT machines. A survey meter (Radios) was used to measure ambient doses in three locations: Doors, Control Rooms and Adjacent Rooms. The ambient dose equivalent (scatter dose) was measured at various distances from the isocenter of the CT unit at various angles to establish isodose cartography. The mean and range of radiation at control room is 10.00-0.20 and mean (7.05μSv/hr,) reception 1.0-0 (0.40) and doors 4.00-100.00 (73.5) for height 1 meter above the ground. For height 2 meters at control room 0-10.00 (6,75), reception 0-90.00 (30) at door 9.00-90.00 (49.50). This study confirms that low levels of radiation dose are received by staff during CT imaging and these levels are within safe limits as prescribed by the national and international regulations. (Author)

  18. Dosimetric comparison of seed strength for I-125 prostate implants

    International Nuclear Information System (INIS)

    Elliott, S.; Droege, J.; Beaufort, C.

    2004-01-01

    Full text: The strength of 1-125 seeds for prostate brachytherapy has been a topic of increasing popularity in the literature over the last few years. Recent reports, which include planning and clinical studies, compare dosimetry between plans and implants using higher (0.5 - 0.8 U, where IU = I μGym 2 h -1 ) or lower (0.3 - 0.4 U) seed strength. The majority of these studies support higher seed strengths for obtaining optimal dosimetry. At the WBRC, a seed air kerma strength of just under 0.4 U is currently used for seed implants. The purpose of this work is to investigate the use of higher strength seeds for our prostate implants. Twenty-four patients were selected according to prostate size, and re-planned using a seed strength of 0.5 U or 0.6 U. Planning was performed following our standard preplanning guidelines as closely as possible; that is, manual planning using a modified Seattle approach and dosimetry limits for the target volume of D 100 : > 95 Gy, v 100 > 98 %, V 150 : 52 - 62 % and V 200 : 11 - 16 %. Dosimetry from the original preplans was then compared to the dosimetry from the re-planned cases. Satisfactory dosimetry was obtained using 0.5 U or 0.6 U strength seeds. Seed placement was typically around the periphery of the target on all slices, to avoid overdosing the urethra. The mean D 100 (Gy) is marginally improved with the higher seed strength. As expected, the V200 (%) is also higher. The mean number of seeds required per implant decreased by 16 % and 28 % for 0.5 U and 0.6 U seeds respectively. The mean number of needles decreased by 7 needles for 0.6 U seeds, however only by 3 needles for 0.5 U seeds. Rectal doses, when using the higher strength seeds, were easily constrained to less than the original preplan doses. Although there was no apparent trend in dosimetry statistics with volume size, as a function of seed strength, it was noted that the reduction in needle and seed number was most significant for medium and large target volumes. A

  19. Characterisation of a MOSFET-based detector for dose measurement under megavoltage electron beam radiotherapy

    Science.gov (United States)

    Jong, W. L.; Ung, N. M.; Tiong, A. H. L.; Rosenfeld, A. B.; Wong, J. H. D.

    2018-03-01

    The aim of this study is to investigate the fundamental dosimetric characteristics of the MOSkin detector for megavoltage electron beam dosimetry. The reproducibility, linearity, energy dependence, dose rate dependence, depth dose measurement, output factor measurement, and surface dose measurement under megavoltage electron beam were tested. The MOSkin detector showed excellent reproducibility (>98%) and linearity (R2= 1.00) up to 2000 cGy for 4-20 MeV electron beams. The MOSkin detector also showed minimal dose rate dependence (within ±3%) and energy dependence (within ±2%) over the clinical range of electron beams, except for an energy dependence at 4 MeV electron beam. An energy dependence correction factor of 1.075 is needed when the MOSkin detector is used for 4 MeV electron beam. The output factors measured by the MOSkin detector were within ±2% compared to those measured with the EBT3 film and CC13 chamber. The measured depth doses using the MOSkin detector agreed with those measured using the CC13 chamber, except at the build-up region due to the dose volume averaging effect of the CC13 chamber. For surface dose measurements, MOSkin measurements were in agreement within ±3% to those measured using EBT3 film. Measurements using the MOSkin detector were also compared to electron dose calculation algorithms namely the GGPB and eMC algorithms. Both algorithms were in agreement with measurements to within ±2% and ±4% for output factor (except for the 4 × 4 cm2 field size) and surface dose, respectively. With the uncertainties taken into account, the MOSkin detector was found to be a suitable detector for dose measurement under megavoltage electron beam. This has been demonstrated in the in vivo skin dose measurement on patients during electron boost to the breast tumour bed.

  20. Effect of gamma-radiation of pollen tube growth and seed set in barley-rye crosses

    International Nuclear Information System (INIS)

    Rohilla, J.S.; Khanna, V.K.

    1993-01-01

    One variety of barley and one variety of rye were taken to study the effect of gamma-radiation on pollen germination, pollen tube growth and seed set in barley-rye crosses. There was an increase in pollen germination and pollen tube growth over control at 1 kR dose but it was reduced at higher doses. Seed set was maximum at 1 kR and it was more than control from 1-5 kR. Only seeds of the cross Karan - 4 (1 kR)*MRSP-992 were able to germinate. In these germinated seeds the root growth was arrested after the fourth day of germination and they turned brown. The shoot growth was also very poor and it stopped after a week. (author) 11 refs.; 2 tabs

  1. Dosimetry verification of radioactive seed implantation for malignant tumors assisted by 3D printing individual templates and CT guidance

    International Nuclear Information System (INIS)

    Ji, Zhe; Jiang, Yuliang; Guo, Fuxin; Sun, Haitao; Fan, Jinghong; Zhang, Lujing; Wang, Junjie

    2017-01-01

    Objective: We compared the dose distributions of postoperative plans with preoperative plans for 3D printing template-assisted radioactive seed implantations. Methods: A total of 14 patients with malignant tumors enrolled in the study. The dose parameters included D90, minimum peripheral dose, V100, V150, and V200. The statistical method was the paired t-test. Results: There was no significant difference in P values between the two groups for all parameters except for V100. Conclusions: The 3D printing guide template can provide good accuracy for radioactive seed implantation. - Highlights: • It is the first study we as for as we know to compare the preoperative and postoperative dosimetry results of 3D printing templates-assisted radioactive seeds implantation for malignant tumor. • 3D printing guide template can provide good accuracy for radioactive seeds implantation. • The actual dose distributions in postoperative validations were closed to the expectations of preoperative plans. • 3D printing template providing us an effective tool for the standardization and normalization of seed implantation, and having a good application prospect and worthy of further development and popularization.

  2. Germination test for identification of gamma-irradiated bean seeds

    International Nuclear Information System (INIS)

    Wesolowska, B.; Ignatowicz, S.

    1993-01-01

    The feasibility of germination test for the practical detection of irradiated beans has not been investigated. The objective of this study was to determine if the relationship between the root growth rate and radiation dose could be used to produce a rapid analytical method for identification of irradiated beans. Such detection method could be potentially used for both (a) identification of irradiated food, and (b) for quarantine inspection (to certify that the agricultural product has been irradiated, and the pests present in it do not pose a quarantine risk). Results presented in this paper indicate that the germination test is not always capable of discriminating satisfactorily between irradiated and unirradiated samples of bean seeds, because the sensitivity of the test is often higher than the low doses which are suggested for disinfestation purposes. However, using the germination test, an unexperienced person can easily discriminate untreated bean seeds from those irradiated with 0.3-1.5 kGy doses of gamma radiation. (orig./vhe)

  3. The effects of sodium azide on seed germination and seedling growth of chili pepper (Capsicum annum L. cv. Landung)

    Science.gov (United States)

    Yafizham; Herwibawa, B.

    2018-01-01

    This study was aimed to determine the effects of sodium azide on the performance of chili pepper. Dry seeds from pure lines of chili pepper cv. Landung were used in this experiment. Each set containing 50 seeds was placed in nylon fishner bags, washed in flowing water and soaked in distilled water for four hours. After soaking, four sets of seeds were dabbed dry with tissue paper and were treated for two hours at 30 0C in appropriate solution of 0, 0.10, 0.20, 0.40, 0.80, 1.60 mM sodium azide with phosphate buffer at pH 3. After treatment, the seeds were germinated in plastic boxes containing sterilized sand and kept under laboratory condition by supplied with water everyday. The seeds for M1 germination percentage, seedling height, plant height and number of leaves were recorded 30 days and 60 days after treatment, respectively. Seeds which radicle emerged were considered germinated, the seedling and plant height were measured from the tip of primary root to the base of the first leaf pair, and the number of leaves were counted for only fully expanded leaves. A completely randomized block design in four replicates was used throughout the experiment. Data obtained were analysed for range, mean, standard of deviation, and percent of control using Microsoft Office Excel 2007 software. It was concluded that different doses of sodium azide influenced the performances of chili pepper cv. Landung. Very low doses of sodium azide (0-1.60 mM) might be used to study the improvement of chili pepper diversity.

  4. Precedents For Authorization Of Contents Using Dose Rate Measurements

    International Nuclear Information System (INIS)

    Abramczyk, G.; Bellamy, S.; Nathan, S.; Loftin, B.

    2012-01-01

    For the transportation of Radioactive Material (RAM) packages, the requirements for the maximum allowed dose rate at the package surface and in its vicinity are given in Title 10 of the Code of Federal Regulations, Section 71.47. The regulations are based on the acceptable dose rates to which the public, workers, and the environment may be exposed. As such, the regulations specify dose rates, rather than quantity of radioactive isotopes and require monitoring to confirm the requirements are met. 10CFR71.47 requires that each package of radioactive materials offered for transportation must be designed and prepared for shipment so that under conditions normally incident to transportation the radiation level does not exceed 2 mSv/h (200 mrem/h) at any point on the external Surface of the package, and the transport index does not exceed 10. Before shipment, the dose rate of the package is determined by measurement, ensuring that it conforms to the regulatory limits, regardless of any analyses. This is the requirement for all certified packagings. This paper discusses the requirements for establishing the dose rates when shipping RAM packages and the precedents for meeting these requirements by measurement.

  5. Dose-area product measurement for patients in diagnostic radiography

    International Nuclear Information System (INIS)

    Alkhawad, Safaa Ibrahim Awad Elkarim

    2001-09-01

    There is a wide spread of the utilization of medical diagnostic x-ray in Sudan upon the last years, in private clinics as well as in public hospitals. The aim of this study was to measure the doses to patients from x-ray in radiography departments in Khartoum State. Use was made of ionization chamber that measures the product of dose times the exposed area of the patient in units of Gy cm 2 . The work was performed in 7 hospitals over 250 patients. 71.2% of the patients were males and 28.8% females. From this work, it appears that the chest radiography represent 42% of the total exposure of human body organs to radiography, there was also a clear variation in doses resulting from this exposure for different x-ray machines. The results of this study were compared with similar from Germany, Finland, New Zealand and Norway; which are recently available studies. The comparison showed those investigation of abdomen, spine and pelvis result in higher radiation doses. No data for limb exposure were obtained from these countries, in Sudan exposure of the limb carry radiation doses compared to the rest of the human body.(Author)

  6. GAMMA IRRADIATION OF SUGAR BEET SEEDS INDUCED PLANT RESISTANCE TO ROOT-KNOT NEMATODE MELOIDOGYNE INCOGNITA

    International Nuclear Information System (INIS)

    ABD EL FATTAH, A.I.; KAMEL, H.A.; EL-NAGDI, W.M.A.

    2008-01-01

    The main objective of this study was to investigate the effect of irradiation of sugar beet seeds on the plant resistance to root-knot nematode Meloidogyne incognita infection in addition to some morphological parameters, biochemical components and root technological characters. Relative to control (non-irradiated seeds), the obtained data showed that, all doses except 10 Gy significantly increased root length of un inoculated plants and the most effective dose was 200 Gy. All doses significantly decreased root diameter except 50 and 100 Gy. The 10 and 400 Gy significantly reduced root fresh weight while 50, 100 and 200 Gy caused non-significant increase. All doses significantly increased root fresh weight/dry weight than control. There was non-significant effect on the morphological parameters of the plants germinated from gamma irradiated seeds and inoculated with Meloidogyne incognita. Total chlorophyll of seed irradiated and un inoculated plants were significantly reduced by all doses except 200 Gy. All doses of gamma radiation caused non-significant decrease in the total chlorophyll of the infected plants. In un inoculated plants, a significant reduction in the total phenol was occurred due to all doses of gamma radiation. In contrast, in inoculated plants, 10 and 25 Gy caused significant reduction in the total phenol while 50 and 400 Gy caused significant increase in the total phenol.Significant increase in sucrose % was observed due to 10 Gy in the un inoculated plants. The 400 Gy caused significant decrease while other doses caused non-significant decrease in the sucrose %. In the inoculated plants, 50, 100 and 400 Gy caused significant increase in sucrose %. All doses significantly increased total soluble salts percent (TSS %) of either inoculated or un inoculated plants. Purity % was increased by all doses in the inoculated plants.The number of galls and egg masses were reduced gradually by increasing gamma doses and 100 Gy caused the highest reduction 89

  7. The effect of exposure rate of the growth of soybean seedlings grown from gamma irradiated seeds

    International Nuclear Information System (INIS)

    Mohd Yusof, A.; Grunewald, R.

    1981-01-01

    The effect of the gamma ( 137 Cs) total exposure rate of 25 kR delivered at three different exposure rates (887 R/min, 159 R/min and 48 R/min) on soybean seeds was studied by measuring seedling height, cotyledon area, fresh weight, dry weight, Co 2 fixation and RuDP carboxylase activity. The dry weight, CO 2 fixation and irradiated imbibed groups did not show any correlation with exposure rate. Exposure rate effect was shown for the first stage out, no further correlation was observed in the subsequent stages, probably due to the recovery and repair mechanisms that take place as the seedling increases with age. The absence of an exposure rate effect on irradiated imbibed group may be explained in terms of non-detectable damage at a very high dose, since these seedlings exhibited effects that are similar to the effects of seeds exposed to an acute radiation dose. (author)

  8. Preventive Effect of Three Pomegranate (Punica granatum L.) Seeds Fractions on Cerulein-Induced Acute Pancreatitis in Mice.

    Science.gov (United States)

    Minaiyan, Mohsen; Zolfaghari, Behzd; Taheri, Diana; Gomarian, Mahdi

    2014-04-01

    Acute pancreatitis (AP) refers to afflicted inflammation of pancreas with unfavorable adverse effects and developed multiple organ failures. Unfortunately, there is not a certain therapeutic method for this disease. Oxidative stress has a serious role in the pathogenesis of AP. Thus, decreasing of oxidative stress may prevent induction and progression of AP. Punica granatum L. has been extensively used in traditional medicine and possesses various active biological elements. Due to antioxidant and anti-inflammatory properties of pomegranate, it could be considered as a good candidate alternative medicine with beneficial effects on AP. In this study, we decided to study the protective effect of three fractions of pomegranate seeds on cerulein-induced AP. AP was induced in male Syrian mice by five intraperitoneal (i.p.) injection of cerulein (50 μg/kg) with 1 h intervals. Treatments with pomegranate freeze-dried powder (PFDP) and hydroalcoholic pomegranate seeds extract (PSE) at doses of 125, 250, 500 mg/kg (i.p.) were started 30 min before pancreatitis induction. Pomegranate seed oil fraction (PSOF) was orally administered (50, 100, 200 μL/kg) and continued for 10 days. Pancreatic tissue was evaluated for histopathological parameters and pancreatic myeloperoxidase (MPO) activity as well as lipase and amylase levels were measured in plasma. The higher doses of three fractions (250 and 500 mg/kg for PFDP and PSE and doses of 100, 200 μL/kg for PSOF) significantly reduced amylase and lipase activity in serum (at least P < 0.01), pancreatic MPO activity (P < 0.001), edema, leukocyte infiltration and vacuolization in comparison to the control group (P < 0.05). These results propose that pomegranate seeds fractions can prevent and/or treat the AP.

  9. Effect of physical and chemical mutagens on seed germination and survival of seedling in Lycopersicon esculentum Mill

    International Nuclear Information System (INIS)

    Jayabalan, N.; Rao, G.R.

    1987-01-01

    Dry and healthy seeds of Lycopersicon esculentum Mill. var. Co-2 were irradiated with gamma rays at 10 KR, 20 KR, 30 KR, 40 KR and 50 KR. The percentage of seed germination was directly proportional to the dose given. The survival percentage decreased with higher doses. Concentration of EMS and NMU applied, ranged from 10 mM to 50 mM and 1 mM to 5 mM, respectively. The duration of soaking of seed was 4 hours in distilled water and 4 hours in mutagenic agents. In treated seeds, the percentage of germination and survival of seedlings decreased with an increase in concentration of these chemical mutagens. These observations are discussed in detail. (author). 11 refs

  10. Studies on cannabis. III. Young plants from the seed irradiated with /sup 60/Co gamma rays for inhibiting their development after seeding

    Energy Technology Data Exchange (ETDEWEB)

    Shimomura, H; Kuriyama, E; Tomizawa, A [Tokyo Coll. of Pharmacy (Japan)

    1976-01-01

    The seedlings from Cannabis sativa L. seeds irradiated with different doses of ..gamma..-rays were examined, in order to determine the dose sufficient to kill the young plants naturally, before their hallucinnogenic component increases. The seeds of ''Minamioshihara No. 1'', which were harvested in 1972 in Tochigi Prefecture, were irradiated with eight different doses of /sup 60/Co ..gamma..-rays in January 17, 1973, and the seedlings were examined several times during the subsequent 9 months, from March to November 1973, and their morphological and histological effects were examined, and the results are summarized as follows: Samples irradiated with 1500 and 1000 krads developed radicles about 3 mm in length. Samples irradiated with 500, 200, and 50 krads grew into young plants with the first set of leaves, without lateral roots. Samples irradiated with 30 krads grew to about 10 cm high with a few lateral roots, and the epicotyls about 1 cm in length. These young plants from the irradiated seeds stayed in the same condition and then died. Samples irradiated with 15 and 5 krads grew in the same way as the controls until the stage of flowering. Samples irradiated with 500, 200, 50, and 30 krads showerd the cell membranes of endodermis and pericycle to be partially lignified and suberized. The degree of change was related to the dose of ..gamma..-rays. Samples irradiated with 30 krads showed withered cells near the end of the lateral nerves on the first and second set of leaves. The economical dose of /sup 60/Co ..gamma..-rays for inhibiting young plants from developing into adult ones was a minimum of 30 krads which made the young plants die. Irradiation with 50 krads of ..gamma..-rays will be required to kill the young plants completely before they develop the hallucinogenic component.

  11. Effect of 125I seeds and 103Pd stents on proliferation of vascular smooth muscle cells

    International Nuclear Information System (INIS)

    Zhu Jun; Zhu Ruisen

    2004-01-01

    To establish the theoretical and practical base for implementing radioactive stents aft PTCA in order to prevent restenosis, in vitro observation was taken over the effects of 12 '5I-seeds and 103 Pd-implanted stents on the vascular smooth muscle cell (VSMC) proliferation. In vitro VSMC model from guinea-pig aortic arteries was established using adherent cell culture methods. The effects of 125 I-seeds and 103 Pd-implanted stents on the VSMC proliferation, with or without fetal bovine serum (FCS), were investigated through cell counting methods and 3 H-TDR implementation tests. It was shown that (1) 10% FCS significantly promoted the DNA synthesis of VSMC (P 125 I-seeds and 103 Pd-implanted stents inhibited the VSMC DNA synthesis in dose-dependent manner, regardless of 10% FCS inducement. At lower radioactive doses, neither 125 I-seeds (18.5-74 kBq) nor 103 Pd-implanted stents (1.48-2.96 MBq) exhibited distinctive effects on the VSMC DNA synthesis (P>0.05); and (3) 48 hour exposure from 125 I-seeds at 128 kBq or 10 '3Pd-implanted stents at 7.4 MBq did not result in VSMC morphological alteration, but 125 I-seeds at 370 kBq caused cells' morphological changes. Therefore both 125 I-seeds and 103 Pd-implanted stents inhibit the in vitro VSMC DNA synthesis, and the inhibition effects are significantly related to their exposure duration and doses. (authors)

  12. Measurement of spatial dose-rate distribution using a position sensitive detector

    International Nuclear Information System (INIS)

    Emoto, T.; Torii, T.; Nozaki, T.; Ando, H.

    1994-01-01

    Recently, the radiation detectors using plastic scintillation fibers (PSF) have been developed to measure the positions exposed to radiation such as neutrons and high energy charged particles. In particular, the time of flight (TOF) method for measuring the difference of time that two directional signals of scintillation light reach both ends of a PSF is a rather simple method for the measurement of the spatial distribution of fast neutron fluence rate. It is possible to use the PSF in nuclear facility working areas because of its flexibility, small diameter and long length. In order to apply TOF method to measure spatial gamma dose rate distribution, the characteristic tests of a detector using PSFs were carried out. First, the resolution of irradiated positions and the counting efficiency were measured with collimated gamma ray. The sensitivity to unit dose rate was also obtained. The measurement of spatial dose rate distribution was also carried out. The sensor is made of ten bundled PSFs, and the experimental setup is described. The experiment and the results are reported. It was found that the PSF detector has the good performance to measure spatial gamma dose rate distribution. (K.I.)

  13. Changes during imbition of irradiated dry seeds of lettuce

    Energy Technology Data Exchange (ETDEWEB)

    Smith, M T [Natal Univ., Durban (South Africa). Dept. of Biological Sciences

    1981-01-01

    Since ionizing radiation has been shown to produce free-radicals in dry seeds, effect peroxidation of lipids in model systems, and cause changes in membrane permeability, it was decided to subject dry seeds of lettuce to gamma irradiation to determine whether the cytological changes which occurred on subsequent imbition are similar in any way to those occurring during natural ageing in dry storage. Seeds of 3% moisture content were radiated with gamma rays from a Cobalt 60 source at doses between 3,4 kGy and 23,8 kGy and the root tips prepared for TEM after 5 and 12 hours imbition. The cytological changes which occurred are shortly discussed.

  14. Changes during imbition of irradiated dry seeds of lettuce

    International Nuclear Information System (INIS)

    Smith, M.T.

    1981-01-01

    Since ionizing radiation has been shown to produce free-radicals in dry seeds, effect peroxidation of lipids in model systems, and cause changes in membrane permeability, it was decided to subject dry seeds of lettuce to gamma irradiation to determine whether the cytological changes which occurred on subsequent imbition are similar in any way to those occurring during natural ageing in dry storage. Seeds of 3% moisture content were radiated with gamma rays from a Cobalt 60 source at doses between 3,4 kGy and 23,8 kGy and the root tips prepared for TEM after 5 and 12 hours imbition. The cytological changes which occurred are shortly discussed

  15. Effect of gamma radiation of 60Co in the conservation of seeds and on the productivity of bean plant (Phaseolus vulgaris L.)

    International Nuclear Information System (INIS)

    Marcos Filho, Julio

    1971-01-01

    Seeds of the field bean variety 'Goiano Precoce' (Phaseolus vulgaris L.) subjected to various radiation doses ( 60 Co) ( Co) were used in a series of experiments with the objective of studying the different aspects of seed behavior thus treated. The radiation doses, comprising six treatments, varied from 0,0 to 6,4 krad of gamma radiation. Effect on seed germination and seedling dry weight was studied by means of a factorial experiment conducted under laboratory controlled conditions. The factors used were the radiation doses and nine increasing lengths of time from date of seed irradiation. Seed vigor was determined by the rate of seedling emergence when planted in small field plots. A factorial design was used. The variables were the radiation dosages and six lengths of time elapsed since date of seed irradiation. The effect of seed irradiation on yield was evaluated by means of two randomized block design field experiments. After the seed vigor experiment was conducted infestation by the bean weevil, Acanthoscelidcs obtectus Say , was observed in irradiated seeds stored under normal conditions, indicating a relationship between radiation dosage and insect damage. An analysis was made of this effect at fourteen increasing time intervals. The analysis was made according to a factorial scheme considering as factors radiation dosage and time interval. The following conclusions could be drawn from the analysis and discussion of the results obtained: a) Seed germination was adversely affected by all radiation doses in relation to the check treatment. This effect however decreased significantly with storing time. b) Seed vigor was higher for those treated with 0,4 , 0,8 and 1,6 krad when compared with those that were not irradiated. c) Pod and seed weight were lowered by the 1,6 and 6,4 krad radiation doses in relation to the check treatment. d) Infestation by the bean weevil was significantly checked by all radiation treatments in relation to the check treatment. e

  16. Direct measurement of annual β dose using TLD on porcelain

    International Nuclear Information System (INIS)

    Leung, P.L.; Stokes, M.J.; Xia Junding; Wang Weida; Zhou Zhixin

    1999-01-01

    In order to improve accuracy of TL authentication test for porcelain, a method of direct measurement of annual β dose using ultrathin TLD (CaSO 4 :Tm) on porcelain was studied. Since the TLD was placed into a hole left after sampling for the TL measurement, the method will not cause any new damage to the studied object. The results show that the technique is suitable for measuring annual β dose and improving accuracy of TL authentication test for both porcelain and pottery

  17. Real-time measurement and monitoring of absorbed dose for electron beams

    Science.gov (United States)

    Korenev, Sergey; Korenev, Ivan; Rumega, Stanislav; Grossman, Leon

    2004-09-01

    The real-time method and system for measurement and monitoring of absorbed dose for industrial and research electron accelerators is considered in the report. The system was created on the basis of beam parameters method. The main concept of this method consists in the measurement of dissipated kinetic energy of electrons in the irradiated product, determination of number of electrons and mass of irradiated product in the same cell by following calculation of absorbed dose in the cell. The manual and automation systems for dose measurements are described. The systems are acceptable for all types of electron accelerators.

  18. Real-time measurement and monitoring of absorbed dose for electron beams

    Energy Technology Data Exchange (ETDEWEB)

    Korenev, Sergey E-mail: sergey_korenev@steris.com; Korenev, Ivan; Rumega, Stanislav; Grossman, Leon

    2004-10-01

    The real-time method and system for measurement and monitoring of absorbed dose for industrial and research electron accelerators is considered in the report. The system was created on the basis of beam parameters method. The main concept of this method consists in the measurement of dissipated kinetic energy of electrons in the irradiated product, determination of number of electrons and mass of irradiated product in the same cell by following calculation of absorbed dose in the cell. The manual and automation systems for dose measurements are described. The systems are acceptable for all types of electron accelerators.

  19. Real-time measurement and monitoring of absorbed dose for electron beams

    International Nuclear Information System (INIS)

    Korenev, Sergey; Korenev, Ivan; Rumega, Stanislav; Grossman, Leon

    2004-01-01

    The real-time method and system for measurement and monitoring of absorbed dose for industrial and research electron accelerators is considered in the report. The system was created on the basis of beam parameters method. The main concept of this method consists in the measurement of dissipated kinetic energy of electrons in the irradiated product, determination of number of electrons and mass of irradiated product in the same cell by following calculation of absorbed dose in the cell. The manual and automation systems for dose measurements are described. The systems are acceptable for all types of electron accelerators

  20. The effect of low dose gamma irradiation on maize production (1985-1988)

    International Nuclear Information System (INIS)

    Al-Oudat, M.; Khalifa, K.

    1990-06-01

    Presowing seed irradiation has been reported as a useful application of radiation in agriculture to stimulate growth and increase the yield of certain field crops. To the best of our knowledge the feasibility of this treatment has not yet been tested on maize in Syria. Our experiments were carried out in controlled, in field conditions, and in a large scale application. Samples of air dried seeds of maize (Var. Gota-82 and LG-11) of previous season were irradiated by gamma-rays from a 137 Cs sourse using doses of 5, 7.5, 10, 15, 20, 30, 40 and 50 Gy. at dose rate of 9.8 - 9.2 Gy/min. Then were planted after 2 days from irradiation with unirradiated control, in complete randomized block design and replicated 4 times for four seasons (1985-1988). The date revealed that gamma irradiation, at interval doses of 5 - 10 Gy led to, first: Acceleration of seed germination, faster development, intensive development of root system, increase plant hieght (12 - 19%) and significant increase in ear size and number, and second: Increase both green mass (15 - 35%) and seed yield (10 - 31%), and percentage of seed protein (2 - 17%). Large scale applications were performed in 1987 and 1988 using a transportable irradiation unit POC-1 137 Cs and dose of 7.5 Gy. A significant yield increase was obtained from all fields. The average percentage increment varied from 13 - 30% which is approximately 382-765 Kg/h. Therefore, presowing seed irradiation with low doses gamma irradiation ranging from 5 to 10 Gy, was found to be feasible for application in qualitative and quantitative improvement of maize yield. (author). 38 refs., 12 figs., 44 tabs

  1. Fiber optical dose rate measurement based on the luminescence of beryllium oxide

    Directory of Open Access Journals (Sweden)

    Teichmann Tobias

    2018-01-01

    Full Text Available This work presents a fiber optical dose rate measurement system based on the radioluminescence and optically stimulated luminescence of beryllium oxide. The system consists of a small, radiation sensitive probe which is coupled to a light detection unit with a long and flexible light guide. Exposing the beryllium oxide probe to ionizing radiation results in the emission of light with an intensity which is proportional to the dose rate. Additionally, optically stimulated luminescence can be used to obtain dose and dose rate information during irradiation or retrospectively. The system is capable of real time dose rate measurements in fields of high dose rates and dose rate gradients and in complex, narrow geometries. This enables the application for radiation protection measurements as well as for quality control in radiotherapy. One inherent drawback of fiber optical dosimetry systems is the generation of Cherenkov radiation and luminescence in the light guide itself when it is exposed to ionizing radiation. This so called “stem” effect leads to an additional signal which introduces a deviation in the dose rate measurement and reduces the spatial resolution of the system, hence it has to be removed. The current system uses temporal discrimination of the effect for radioluminescence measurements in pulsed radiation fields and modulated optically stimulated luminescence for continuous irradiation conditions. This work gives an overview of the major results and discusses new-found obstacles of the applied methods of stem discrimination.

  2. Measurement of absorbed doses near interfaces, and dose mapping using gas chromic dosimetry media. Vol. 2

    Energy Technology Data Exchange (ETDEWEB)

    Abdel-Rehim, F; Said, F I.A.; Abdel-Fattah, A A [National Centre for Radiation Research and Technology, Atomic Energy Athority, P.O.Box 29 Nasr City, Cairo (Egypt)

    1996-03-01

    Gas chromic dosimetry media is a thin-coated film which has advantages for high-dose radiation dosimetry, and produces high-resolution radiation image for gamma radiation. Therefore, these films were calibrated for the dose range 0.1-50 kGy in terms of increase in absorbance at 600 nm, 400 nm; increase in the area of the absorption spectra in the ranges 395-405 nm and 320-450 nm wave length as a function of absorbed dose in water. The calibrated films were used for measurement of absorbed doses close to metal interface, and dose mapping of the radiation field inside product box during a run for sterilizing surgical gloves at the mega-gamma irradiation facility.7 figs.

  3. Maturation of sugar maple seed

    Science.gov (United States)

    Clayton M., Jr. Carl; Albert G., Jr. Snow; Albert G. Snow

    1971-01-01

    The seeds of a sugar maple tree (Acer saccharum Marsh.) do not mature at the same time every year. And different trees mature their seeds at different times. So time of year is not a reliable measure of when seeds are ripe. Better criteria are needed. In recent studies we have found that moisture content and color are the best criteria for judging when sugar maple...

  4. [The NIR spectra based variety discrimination for single soybean seed].

    Science.gov (United States)

    Zhu, Da-Zhou; Wang, Kun; Zhou, Guang-Hua; Hou, Rui-Feng; Wang, Cheng

    2010-12-01

    With the development of soybean producing and processing, the quality breeding becomes more and more important for soybean breeders. Traditional sampling detection methods for soybean quality need to destroy the seed, and does not satisfy the requirement of earlier generation materials sieving for breeding. Near infrared (NIR) spectroscopy has been widely used for soybean quality detection. However, all these applications were referred to mass samples, and they were not suitable for little or single seed detection in breeding procedure. In the present study, the acousto--optic tunable filter (AOTF) NIR spectroscopy was used to measure the single soybean seed. Two varieties of soybean were measured, which contained 60 KENJIANDOU43 seeds and 60 ZHONGHUANG13 seeds. The results showed that NIR spectra combined with soft independent modeling of class analogy (SIMCA) could accurately discriminate the soybean varieties. The classification accuracy for KENJIANDOU43 seeds and ZHONGHUANG13 was 100%. The spectra of single soybean seed were measured at different positions, and it showed that the seed shape has significant influence on the measurement of spectra, therefore, the key point for single seed measurement was how to accurately acquire the spectra and keep their representativeness. The spectra for soybeans with glossy surface had high repeatability, while the spectra of seeds with external defects had significant difference for several measurements. For the fast sieving of earlier generation materials in breeding, one could firstly eliminate the seeds with external defects, then apply NIR spectra for internal quality detection, and in this way the influence of seed shape and external defects could be reduced.

  5. Alterations in polyunsaturated fatty acid composition of Voandzeia subterranea seeds upon gamma irradiation

    International Nuclear Information System (INIS)

    Andrianarison, R.H.; Rakotoarisoa, Z.; Tixier, M.; Beneytout, J.L.

    1992-01-01

    Exposure of V. subterranea seeds, a herbaceous plant from Madagascar belonging to the family of legumes, to gamma irradiation resulted in a polyunsaturated fatty acids decrease associated with the formation of UV-absorbing substances. The finding that products containing conjugated diene structure are formed during lipid extract irradiation indicates that hydroperoxy fatty acids may arise not only by enzymatic reactions but also by nonenzymatic oxygenation of polyunsaturated fatty acids promoted by ionizing radiation. Dehulled green seeds, flour made from dehulled green seeds, and lipid extract were studied for irradiation dose dependent changes in fatty acids compositions and hydroperoxydiene synthesis. The irradiation dose is more efficient in lipid extract than in dehulled green seeds or in flour made from these seeds, suggesting that the formation of UV-absorbing products is not a reliable clue for enzyme activity owing to the absence of protein in lipid extract. A homolytic pathway for the biogenesis of hydroperoxy fatty acids from polyunsaturated fatty acids is proposed. This involves an initiating radical which promotes a chain mechanism in which the O2 adsorbed is converted to hydroperoxide. Conclusively, preservation of fatty acid oxygenation should be a primary goal in the ionizing radiation processes of V. subterranea seeds and generally in the preservation of food of plant origin by ionizing radiation

  6. Structural characterization of annatto seeds (Bixa orellana) by transmission and scanning electron microscopy submitted to gamma radiation for dormancy break

    Energy Technology Data Exchange (ETDEWEB)

    Harder, Marcia N.C.; Nogueira, Neusa L.; Arthur, Valter; Rossi, Monica L.; Rodriguez, Adriana P.M. [Centro de Energia Nuclear na Agricultura (CENA/USP), Piracicaba, SP (Brazil)]. E-mails: mnharder@cena.usp.br; nogueira@cena.usp.br; arthur@cena.usp.br; mnicalr@cena.usp.br; riana@cena.usp.br

    2007-07-01

    The annatto (Bixa orellana) is the only species of the Bixaceae family. From the seeds an important food colorant is obtained, bixin, for the industry and domestic use. More recently studies have focused more extensively in medicinal purpose of the species. Due to structural and physiologic characteristics, the seeds have low germination rate, around 30 %. The irradiation of seeds with gamma radiation can promote the increase and/or acceleration of germination, better plant development and productivity, among other aspects. The radiation doses used for this purpose should not cause genetic modifications in the organism, hence experimentation is needed to define the appropriate doses. Absence of research done annatto related to the use of the irradiation aiming at the increase of germination rates lead to the structural characterization of the annatto seeds submitted to gamma radiation through transmission (TEM) and scanning electron microscopy (SEM). The objective of this study was to verify the effect of radiation on the seeds structures during the process of dormancy break. Dry seeds and seeds immersed in distilled water for 24 hours were submitted to gamma radiation from source of Co{sup 60} type Gammacell-220 at CENA/USP, at doses 100 Gy. After irradiation the seeds were processed for TEM and SEM. Preliminary results, showed structural modifications in the seeds. (author)

  7. COMPUTED TOMOGRAPHY DOSE INDEX MEASUREMENT FOR Hi-ART MEGAVOLTAGE HELICAL CT.

    Science.gov (United States)

    Liu, Minglu; Wang, Yunlai; Liao, Xiongfei

    2016-11-01

    On-line megavoltage computed tomography (MVCT) images are used to verify patient daily set-up in Hi-ART helical TomoTherapy unit. To evaluate the patient dose from MVCT scanning in image guidance, weighted computed tomography (CT) dose index (CTDI w ) was measured with PTW TM30009 CT pencil chamber in head and body phantoms for slice thicknesses of 2, 4 and 6 mm with different scan lengths. Dose length products (DLPs) were subsequently calculated. The CTDI w and DLP were compared with XVI kV CBCT and Brilliance simulator CT for routine clinical protocols. It was shown that CTDI and DLP had close relationship with the slice thickness and the scan length. The dose distribution in the transversal plane was very inhomogeneous due to the attenuation of the couch. Patient dose from MVCT was lower than XVI CBCT for the head scan, while larger for body scan. CTDI w , which is measured easily and reproducibly, can be used to assess the patient dose in MVCT. Regular measurement should be performed in QA & QC programmes. Appropriate slice thickness and scan range should be chosen to reduce the patient dose. © The Author 2015. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  8. Measurements of cosmic-ray doses in commercial airline cabins

    International Nuclear Information System (INIS)

    Okano, M.; Fujitaka, K.; Izumo, K.

    1996-01-01

    Cosmic radiation doses which aircrew and air passengers receive in airplanes have been calling attention in many countries especially in the last decade. In this relation, various types of information had been reported on cosmic radiation intensity. In Japan, the cosmic radiation intensity had been measured in commercial airline cabins as well as chartered flights. While the intensity depends on altitude, geomagnetic latitude (or cutoff rigidity), and temporal variation of the solar activity, their doses are often speculated based on paper records on airflights combined with the intensity-altitude relationship. In this study, however, efforts were made to estimate more realistic integrated doses in airline cabins based on actual on-board measurements which had been conducted several dozens of times in each year (e.g., 45 times in 1994 and 27 times in 1995). (author)

  9. Technology Development for Radiation Dose Measurement and Evaluation

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Bong Hwan; Chang, S. Y.; Lee, T. Y. (and others)

    2007-06-15

    The correction factors essential for the operation of In-Vivo counting system were produced and implemented into a field operation for the improvement of accuracy in measurement of the radioactivity inside a human body. The BiDAS2007 code which calculate an internal dose was developed by upgrading the former code prepared in the previous stage of this project. The method of using the multibioassy data, the maximum likelihood function and the Bayesian statistics were established to an internal dose based on the measurement data of radioactivity, intakes and retention of radioactivity in a human body and it can improve the accuracy in estimation of the intakes of radioactivity and the committed effective dose equivalent. In order to solve the problem of low detection efficiency of the conventional Bonner Sphere (BS) to a high energy neutron, the extended BS's were manufactured and the technique for neutron field spectrometry was established. The fast neutron and gamma spectrometry system with a BC501A scintillation detector was also prepared. Several neutron fluence spectra at several nuclear facilities were measured and collected by using the extended BS. The spectrum weighted responses of some neutron monitoring instruments were also derived by using these spectra and the detector response functions. A high efficient TL material for the neutron personal dosimeter was developed. It solved the main problem of low thermal stability and high residual dose of the commercial TLDs and has the sensitivity to neutron and to gamma radiation with 40 and 10 times higher respectively than them.

  10. Toxicity of dietary Heliotropium dolosum seed to mice.

    Science.gov (United States)

    Eröksüz, Y; Eröksüz, H; Ozer, H; Sener, B; Tosun, F; Akyüz, C

    2001-06-01

    Experimental pyrrolizidine alkaloid intoxication was produced in inbred Swiss mice. Animals were fed diets containing 0, 1, 3, 5, or 10% Heliotropium dolosum seed for 24 w. The seeds contained 0.13% total alkaloid concentration composed of 4 specific components: lasiocarpine (78.79%), heliosupine (11.96%), echimidine (5.43%), and heliotrine (3.82%). Deaths occurred in all dosed groups and increased with dietary seed concentration. Massive to submassive liver necrosis together with sinusoidal congestion, and hemorrhage or multifocal hepatocytic necrosis was limited to animals which survived 5 w. Intranuclear eosinophilic inclusions in hepatocytes and bile duct and ductular cell hyperplasia were the most noticeable lesions in the 1, 3, and 5% groups. There was mild to moderate renal tubular megalocytosis in the 3, 5, and 10% groups. It seems likely that H dolosum seed, at least to a limited extent, constitutes a health hazard for certain animal species.

  11. FBX dosimetry for point dose measurements in head and neck cancer patients

    International Nuclear Information System (INIS)

    Balraj, A.; Thakur, P.K.; Bhatnagar, S.; Vidyasagar, P.B.; Nirhali, Amit; Semwal, M.K.

    2007-01-01

    FBX dosimeter is mainly based on the determination of the radiation dose from the chemical changes produced in an irradiated medium, which can be measured by Spectrophotometry or Colorimetry, for which adequate FBX solution of 2 ml required for measuring the optical density (OD). To measure the point dose using 2 ml solution may lead to error in the measured dose since the solution may occupy 2 cc volume of the point measured. In head and neck carcinoma patients, the treatment area involves curvatures. Fixing 2 ml vial at the body surface is difficult and leads to give wrong readings. In this study we have measured the entrance and exit dose by filling 0.5 ml solution in a flexible catheter and placed at a point in the patient body surface during the radiation treatment. The solution was diluted adding 1.5 ml distilled water to measure the OD in the colorimeter

  12. Surface dose measurements and comparison of unflattened and flattened photon beams

    Directory of Open Access Journals (Sweden)

    Ashokkumar Sigamani

    2016-01-01

    Full Text Available The purpose of this study was to evaluate the central axis dose in the build-up region and the surface dose of a 6 MV and 10 MV flattened photon beam (FB and flattening filter free (FFF therapeutic photon beam for different square field sizes (FSs for a Varian Truebeam linear accelerator using parallel-plate ionization chamber and Gafchromic film. Knowledge of dosimetric characteristics in the build-up region and surface dose of the FFF is essential for clinical care. The dose measurements were also obtained empirically using two different commonly used dosimeters: a p-type photon semiconductor dosimeter and a cylindrical ionization chamber. Surface dose increased linearly with FS for both FB and FFF photon beams. The surface dose values of FFF were higher than the FB FSs. The measured surface dose clearly increases with increasing FS. The FFF beams have a modestly higher surface dose in the build-up region than the FB. The dependence of source to skin distance (SSD is less significant in FFF beams when compared to the flattened beams at extended SSDs.

  13. WE-A-17A-11: Implanted Brachytherapy Seed Movement Due to Transrectal Ultrasound Probe-Induced Prostate Deformation

    Energy Technology Data Exchange (ETDEWEB)

    Liu, D; Usmani, N; Sloboda, R [Cross Cancer Institute, Edmonton, Alberta (Canada); University of Alberta, Edmonton, Alberta (Canada); Meyer, T; Husain, S; Angyalfi, S [Tom Baker Cancer Centre, Calgary, Alberta (Canada); University of Calgary, Calgary, Alberta (Canada); Kay, I [Canterbury District Health Board, Christchurch (New Zealand)

    2014-06-15

    Purpose: To characterize the movement of implanted brachytherapy seeds due to transrectal ultrasound probe-induced prostate deformation and to estimate the effects on prostate dosimetry. Methods: Implanted probe-in and probe-removed seed distributions were reconstructed for 10 patients using C-arm fluoroscopy imaging. The prostate was delineated on ultrasound and registered to the fluoroscopy seeds using a visible subset of seeds and residual needle tracks. A linear tensor and shearing model correlated the seed movement with position. The seed movement model was used to infer the underlying prostate deformation and to simulate the prostate contour without probe compression. Changes in prostate and surrogate urethra dosimetry were calculated. Results: Seed movement patterns reflecting elastic decompression, lateral shearing, and rectal bending were observed. Elastic decompression was characterized by anterior-posterior expansion and superior-inferior and lateral contractions. For lateral shearing, anterior movement up to 6 mm was observed for extraprostatic seeds in the lateral peripheral region. The average intra-prostatic seed movement was 1.3 mm, and the residual after linear modeling was 0.6 mm. Prostate D90 increased by 4 Gy on average (8 Gy max) and was correlated with elastic decompression. For selected patients, lateral shearing resulted in differential change in D90 of 7 Gy between anterior and posterior quadrants, and increase in whole prostate D90 of 4 Gy. Urethra D10 increased by 4 Gy. Conclusion: Seed movement upon probe removal was characterized. The proposed model captured the linear correlation between seed movement and position. Whole prostate dose coverage increased slightly, due to the small but systematic seed movement associated with elastic decompression. Lateral shearing movement increased dose coverage in the anterior-lateral region, at the expense of the posterior-lateral region. The effect on whole prostate D90 was smaller due to the subset

  14. Dose requirements for microbial decontamination of botanical materials by irradiation

    International Nuclear Information System (INIS)

    Razem, D.; Katusin-Razem, Branka

    2002-01-01

    Microbial contamination levels and corresponding resistivities to irradiation (expressed as dose required for the first 90% reduction, D first 9 0% r ed ) were analyzed in a number of various botanical materials. The following generalizations could be made: total aerobic plate count is the most informative measure of contamination; the probability of contamination depends on available surface of the material and processing history: flowers and leaves usually contain more contamination than fruits and seeds, while crude herbs contain more than extracts; liquid extracts are more contaminated than dry ones. At the same time, resistivity to irradiation increases approximately in the reverse order of contamination level on going from flowers and leaves, to fruits and seeds, to liquid and dry extracts. The two quantities, probability of contamination and D first 9 0% r ed being inversely related, the treatment dose needed to reduce initial contamination to tolerable level amounts to between 4 and 30 kGy under a typical scenario, and between 8 and 40 kGy under the worst-case scenario for the whole range of raw materials and botanical products

  15. Indoor gamma dose measurements in Gudalore (India) using TLD

    International Nuclear Information System (INIS)

    Sivakumar, R.; Selvasekarapandian, S.; Mugunthamanikandan, N.; Raghunath, V.M.

    2002-01-01

    Indoor gamma radiation dose rates were measured inside residential buildings in Gudalore using a CaSO 4 : Dy thermoluminescent dosimeter for 1 year . Significant seasonal variations are observed. The highest dose rate is observed during summer and the lowest in winter. The dose rates observed are between 77.9 and 229.3 nGy h -1 and may be attributed to the type of building materials used in the dwellings monitored. The calculated mean annual effective dose equivalent rates range between 477.6 μSv y -1 , for the inhabitants of mud houses to 1406.3 μSv y -1 , for those living in terrace houses made of cement and brick

  16. Effect of pre-sowing gamma irradiated lupin seeds on growth characters and yield components

    International Nuclear Information System (INIS)

    Ragab, M.A.

    1988-01-01

    Selected seeds of lupin were exposed to Co 60 -source to achieve doses of 2.5, 5, 10, 20, 40, 80, 160, or 320 Grey, beside the control treatment, irradiated and unirradiated seeds were sown and the raised plants were grown under field condition at Agric. Dept. of Soil and Water Res. A.E.A. Representative plant samples were taken at early growth stage 15-days-old seedling at flowering and at harvest. The gained results could be summarized as follows: Plant growth parameters: Plant height, particularly at early stages and at flowering and the produced dry matter were statistically affected by the treatments. Leaf pigment content was intensified by almost 14-28% over control treatment. Total carbohydrates and soluble protein in plant leaves were statistically influenced by the applied irradiation doses. Number of pods was materially affected by the treatments while no remarkable effect was noted as far as a number of seeds/plant and dry weight of seeds/plant were considered: consequently: seed index was not materially affected

  17. Gamma Radiation Impact on the Survival Microflora and Biochemical Constituents of Stored Anise Seeds (Pimpenella anisum L.)

    International Nuclear Information System (INIS)

    Mohamed, G.A.; Botros, H.W.; Ahmed, B.M.; Abo-El-Seoud, M.A.

    2010-01-01

    Anise seeds (Pimpenella anisum L.) were exposed to gamma irradiation doses (0, 4, 8, 16 and 32 KGy). Irradiated and un-irradiated anise seeds were stored for 3, 6 and 12 months and tested for their microbial population . In addition, the chemical constituents (volatile oils, fatty acids, lipids and sugars) were evaluated. The predominant microorganisms contaminated anise seeds include different fungal species identified as Aspergillus niger, A. ochraceus, A. parasiticus, A. flavus, A. fumigatus , Penicillium funiculosum , P. italicum , Rhizopus sp. and Trichoderma viride. Different bacterial species as Bacillus circulans, B. subtilis, B. megaterium, B. brevis, Pseudomonas fluorescens, P. oleourans and Alicyclobacillus acidocaldarius were recorded. The imposed irradiation doses showed a promising effect to decontaminate the microbial load , which in turn showed prolong the storage periods. Volatile oil content was relatively declined during storage. In addition, some alternations were happened regarding the essential oils constituents. However, the applied irradiation doses maintained the volatile oil content and retained its constituents near to the normal control. Total lipids content were not influenced by either the applied storage periods or the used gamma irradiation doses. However, the fatty acids methyl ester showed some changes due to the imposed treatments. Sugars content were increased in the stored and un-irradiated seeds, however, the exposure to gamma radiation reduced this increase and retained sugars content near to the normal level of the control seeds.

  18. Dosimetric evaluation of the OneDoseTM MOSFET for measuring kilovoltage imaging dose from image-guided radiotherapy procedures.

    Science.gov (United States)

    Ding, George X; Coffey, Charles W

    2010-09-01

    The purpose of this study is to investigate the feasibility of using a single-use dosimeter, OneDose MOSFET designed for in vivo patient dosimetry, for measuring the radiation dose from kilovoltage (kV) x rays resulting from image-guided procedures. The OneDose MOSFET dosimeters were precalibrated by the manufacturer using Co-60 beams. Their energy response and characteristics for kV x rays were investigated by using an ionization chamber, in which the air-kerma calibration factors were obtained from an Accredited Dosimetry Calibration Laboratory (ADCL). The dosimetric properties have been tested for typical kV beams used in image-guided radiation therapy (IGRT). The direct dose reading from the OneDose system needs to be multiplied by a correction factor ranging from 0.30 to 0.35 for kilovoltage x rays ranging from 50 to 125 kVp, respectively. In addition to energy response, the OneDose dosimeter has up to a 20% reduced sensitivity for beams (70-125 kVp) incident from the back of the OneDose detector. The uncertainty in measuring dose resulting from a kilovoltage beam used in IGRT is approximately 20%; this uncertainty is mainly due to the sensitivity dependence of the incident beam direction relative to the OneDose detector. The ease of use may allow the dosimeter to be suitable for estimating the dose resulting from image-guided procedures.

  19. Mutational effects of space flight on Zea mays seeds

    Science.gov (United States)

    Mei, M.; Qiu, Y.; He, Y.; Bucker, H.; Yang, C. H.

    1994-01-01

    The growth and development of more than 500 Zea mays seeds flown on Long Duration Exposure Facility (LDEF) were studied. Somatic mutations, including white-yellow stripes on leaves, dwarfing, change of leaf sheath color or seedling color were observed in plants developed from these seeds. When the frequency of white-yellow formation was used as the endpoint and compared with data from ground based studies, the dose to which maize seeds might be exposed during the flight was estimated to be equivalent to 635 cGy of gamma rays. Seeds from one particular holder gave a high mutation frequency and a wide mutation spectrum. White-yellow stripes on leaves were also found in some of the inbred progenies from plants displayed somatic mutation. Electron microscopy studies showed that the damage of chloroplast development in the white-yellow stripe on leaves was similar between seeds flown on LDEF and that irradiated by accelerated heavy ions on ground.

  20. Measurements of eye lens doses in interventional cardiology using OSL and electronic dosemeters

    International Nuclear Information System (INIS)

    Sanchez, R.M.; Vano, E.; Fernandez, J.M.; Ginjaume, M.; Duch, M.A.

    2014-01-01

    The purpose of this paper is to test the appropriateness of OSL and electronic dosemeters to estimate eye lens doses at interventional cardiology environment. Using TLD as reference detectors, personal dose equivalent was measured in phantoms and during clinical procedures. For phantom measurements, OSL dose values resulted in an average difference of 215 % vs. TLD. Tests carried out with other electronic dosemeters revealed differences up to ±20 % versus TLD. With dosemeters positioned outside the goggles and when TLD doses were >20 μSv, the average difference OSL vs. TLD was 29 %. Eye lens doses of almost 700 μSv per procedure were measured in two cases out of a sample of 33 measurements in individual clinical procedures, thus showing the risk of high exposure to the lenses of the eye when protection rules are not followed. The differences found between OSL and TLD are acceptable for the purpose and range of doses measured in the survey (authors)

  1. Partial dehydration and cryopreservation of Citrus seeds.

    Science.gov (United States)

    Graiver, Natalia; Califano, Alicia; Zaritzky, Noemí

    2011-11-01

    Three categories of seed storage behavior are generally recognized among plant species: orthodox, intermediate and recalcitrant. Intermediate seeds cannot be stored in liquid nitrogen (LN) without a previous partial dehydration process. The water content (WC) of the seeds at the moment of immersion in LN must be regarded as the most critical factor in cryopreservation. The purpose of this study was to investigate the basis of the optimal hydration status for cryopreservation of Citrus seeds: C. sinensis (sweet orange), C. paradisi (grapefruit), C. reticulata (mandarin) in LN. To study the tolerance to dehydration and LN exposure, seeds were desiccated by equilibration at relative humidities between 11 and 95%. Sorption isotherms were determined and modeled; lipid content of the seeds was measured. Seed desiccation sensitivity was quantified by the quantal response model. Differential scanning calorimetry (DSC) thermograms were determined on cotyledon tissue at different moisture contents to measure ice melting enthalpies and unfrozen WC. Samples of total seed lipid extract were also analyzed by DSC to identify lipid transitions in the thermograms. The limit of hydration for LN Citrus seeds treatment corresponded to the unfrozen WC in the tissue, confirming that seed survival strictly depended on avoidance of intracellular ice formation. Copyright © 2011 Society of Chemical Industry.

  2. Measurement of radiation dose in paediatric micturating cystourethrography

    International Nuclear Information System (INIS)

    Hassan, N. E. A.

    2013-06-01

    Paediatrics and children have been recognized that they have a higher risk of developing cancer from the radiation than adults. Therefor, increased attention has been directed towards the dose to the patients. Micturating Cystourethrography (MCU) is a commonly use ed fluoroscopic procedure in children and commonly used to detect the vesicoureteric reflux (VUR) and show urethral and bladder and abnormalities. This study aims to measure the pediatric patients undergoing MCU. The study was carried out in two hospitals in Khartoum. The entrance surface dose (ESD) was determined determined by indirect method for 45 children. Furthermore, the mean ESD, sd and range resulting from MCU procedures has been estimated to be 0.7±.5 (0.2-2.5) mGy for the total patient population. The radiation dose to the patients is well within established safety limits, in the light of the current practice. The radiation dose results of this study are appropriate for adoption as the local initial dose reference level (DRL) value for this technique. The data presented in this study showed our doses to be approximately 50% lower than the lower mean values presented in the literature.(Author)

  3. Developing a single-aliquot protocol for measuring equivalent dose in biogenic carbonates

    International Nuclear Information System (INIS)

    Stirling, R.J.; Duller, G.A.T.; Roberts, H.M.

    2012-01-01

    Exploiting biogenic carbonates as thermoluminescence dosimeters requires an understanding of trap kinetics and an appropriate sequence with which to measure equivalent dose. The trap kinetics of two high temperature peaks (peaks II and III) from calcitic snail opercula have been investigated resulting in the calculation of lifetimes of 7.4 × 10 7 and 1.4 × 10 11 years for the two peaks respectively. Two measurement sequences, based upon changes in the application and measurement of a test dose, have been applied to peaks II and III, and though both methods were equally successful in dose recovery and production of a dose response curve some differences were observed. Primarily, the use of method 1 lead to dose dependant sensitivity change implying competition effects occurring during irradiation; method 2 did not experience this phenomenon. As a consequence method 2 was chosen as the most appropriate protocol for single-aliquot dating of this material. When assessing the TL behaviour of the two peaks, peak II performed poorly in dose recovery experiments recovering a dose 60–100% larger than that applied. Disproportionate growth of peak II in response to a beta dose applied prior to measurement, compared to growth following regeneration doses indicated that peak II was not suitable for use in single-aliquot protocols. However, dose recovery results for peak III were all within errors of unity of the given dose, and peak III was therefore chosen as the most appropriate peak for TL dosimetry in these single-aliquot procedures. The lifetime of charge in peak III is sufficient to date over many millions of years, and furthermore using the chosen method 2 the dose response curve has a D 0 of 3,250 ± 163 Gy allowing dating to over 3 million years.

  4. Polymer gel dosimetry for synchrotron stereotactic radiotherapy and iodine dose-enhancement measurements

    International Nuclear Information System (INIS)

    Boudou, C; Tropres, I; Rousseau, J; Lamalle, L; Adam, J F; Esteve, F; Elleaume, H

    2007-01-01

    Synchrotron stereotactic radiotherapy (SSR) is a radiotherapy technique that makes use of the interactions of monochromatic low energy x-rays with high atomic number (Z) elements. An important dose-enhancement can be obtained if the target volume has been loaded with a sufficient amount of a high-Z element, such as iodine. In this study, we compare experimental dose measurements, obtained with normoxic polymer gel (nPAG), with Monte Carlo computations. Gels were irradiated within an anthropomorphic head phantom and were read out by magnetic resonance imaging. The dose-enhancement due to the presence of iodine in the gel (iodine concentration: 5 and 10 mg ml -1 ) was measured at two radiation energies (35 and 80 keV) and was compared to the calculated factors. nPAG dosimetry was shown to be efficient for measuring the sharp dose gradients produced by SSR. The agreement between 3D gel dosimetry and calculated dose distributions was found to be within 4% of the dose difference criterion and a distance to agreement of 2.1 mm for 80% of the voxels. Polymer gel doped with iodine exhibited higher sensitivity, in good agreement with the calculated iodine-dose enhancement. We demonstrate in this preliminary study that iodine-doped nPAG could be used for measuring in situ dose distributions for iodine-enhanced SSR treatment

  5. Electron scattering effects on absorbed dose measurements with LiF-dosemeters

    International Nuclear Information System (INIS)

    Bertilsson, G.

    1975-10-01

    The investigation deals with absorbed dose measurements with solid wall-less dosemeters. Electron scattering complicates both measurement of absorbed dose and its theoretical interpretation. The introduction of the dosemeter in a medium causes perturbations of the radiation field. This perturbation and its effect on the distribution of the absorbed dose inside the dosemeter is studied. Plane-parallel LiF-teflon dosemeters (0.005 - 0.1 g.cm -2 ) are irradiated by a photon beam ( 137 Cs) in different media. The investigation shows that corrections must be made for perturbations caused by electron scattering phenomena. Correction factors are given for use in accurate absorbed dose determinations with thermoluminescent dosemeters. (Auth.)

  6. Measurement system for depth dose distribution in cancer therapy

    International Nuclear Information System (INIS)

    Nishizawa, Hiroshi; Fujiwara, Hirotsugu; Tsutaka, Yoshikazu; Ikeda, Ikuo

    1999-01-01

    An accurate estimation of an absorbed dose distribution in human tissue is indispensable to efficiently perform radiotherapy in humans. Previously, various methods for such estimation have been developed, however, there is some problem in those methods, it takes too long times (3-4 hours) to determine the absorbed dose distribution through scanning by ionization chamber in water phantom. So, a determination system of depth dose was developed with an aim to determine the absorbed dose of X-ray or electron beam in materials similar to human body. This system was composed of a detector including scintillation fibers which allows emission due to radio-interaction, CCD camera for determination of light distribution of the emission and personal computer for data processing. Though the accuracy of this system was ±2% similar to that of the conventional measuring method, measuring time was reduced to almost 5 min, markedly shorter than that of the conventional water phantom (3-4 hours). The efficacy of works including the adjustment of irradiation system, planning, etc. would be improved by application of this system. (M.N.)

  7. Characteristics of dosemeter types for skin dose measurements in practice

    International Nuclear Information System (INIS)

    Van, D. J.; Bosmans, H.; Marchal, G.; Wambersie, A.

    2005-01-01

    A growing number of papers report deterministic effects in the skin of patients who have undergone interventional radiological procedures. Dose measurements, and especially skin dose measurements, are therefore increasingly important. Methods and acceptable dosemeters are, however, not clearly defined. This paper is the result of a literature overview with regard to assessing the entrance skin dose during radiological examinations by putting a dosemeter on the patient's skin. The relevant intrinsic characteristics, as well as some examples of clinical use of the different detector types, are presented. In this respect, thermoluminescence, scintillation, semiconductor and film dosemeters are discussed and compared with respect to their practical use. (authors)

  8. Determining clinical photon beam spectra from measured depth dose with the Cimmino algorithm

    International Nuclear Information System (INIS)

    Bloch, P.; Altschuler, M.D.; Bjaerngard, B.E.; Kassaee, A.; McDonough, J.

    2000-01-01

    A method to determine the spectrum of a clinical photon beam from measured depth-dose data is described. At shallow depths, where the range of Compton-generated electrons increases rapidly with photon energy, the depth dose provides the information to discriminate the spectral contributions. To minimize the influence of contaminating electrons, small (6x6cm2 ) fields were used. The measured depth dose is represented as a linear combination of basis functions, namely the depth doses of monoenergetic photon beams derived by Monte Carlo simulations. The weights of the basis functions were obtained with the Cimmino feasibility algorithm, which examines in each iteration the discrepancy between predicted and measured depth dose. For 6 and 15 MV photon beams of a clinical accelerator, the depth dose obtained from the derived spectral weights was within about 1% of the measured depth dose at all depths. Because the problem is ill conditioned, solutions for the spectrum can fluctuate with energy. Physically realistic smooth spectra for these photon beams appeared when a small margin (about ±1%) was attributed to the measured depth dose. The maximum energy of both derived spectra agreed with the measured energy of the electrons striking the target to within 1 MeV. The use of a feasibility method on minimally relaxed constraints provides realistic spectra quickly and interactively. (author)

  9. Dose rate measurement of a cobalt source 'Issledovatel' by means of Fricke dosimeter

    CERN Document Server

    Peimel-Stuglik, Z

    2001-01-01

    The results of measurements leading to the elaboration of a reliable and accurate dose rate determination for a cobalt irradiator 'Issledovatel' were presented. The dose measurements were done by means of classic Fricke dosimeter. The conclusions from measurements can be useful also for the dosimetry of other kinds of cobalt irradiators. The measurements were performed by a newly employed Laboratory for Measurements of Technological Doses staff and were a practical test of their proficiency in gamma ray dosimetry.

  10. Influence of foliar fertilization with manganese on germination, vigor and storage time of RR soybean seeds

    Directory of Open Access Journals (Sweden)

    Vanessa Leonardo Ignácio

    2015-10-01

    Full Text Available ABSTRACTThis study aimed to evaluate the influence of foliar fertilizer doses containing Mn of phenological stages of suggested application in RR soybeans, to recover management damages with glyphosate at postemergence application on seed vigor in post-harvest and post six months storage. The seeds originated from a field experiment conducted , which included two applications of glyphosate, concomitant with foliar fertilizer in growth stages V4 and V6, with 0.00, 113.50 and 227.00 mg ha-1doses of Mn2+. Germination, GSI (Germination Speed Index, electrical conductivity tests and the first count of seeds were conducted. The application of Mn did not affect the physiological quality of RR soy in postharvest. However, in post-storage, higher doses of Mn had a negative effect on tests of abnormal seedlings, GSI and electrical conductivity. The applications of Mn, regardless of the developmental stage, did not interfere in the germination and first count tests, with and without storage. The electrical conductivity test showed a higher correlation with the seed germination test in the post-harvest treatment.

  11. Measurements Of Fingers Doses Of Staff Members In Nuclear Medicine Department

    International Nuclear Information System (INIS)

    AL LEHYANI, S.H.; SHOUSHA, H.A.; HASSAN, R.A.

    2009-01-01

    For some occupationally radiation exposed groups, the hands are more heavily exposed to ionizing radiation than the rest of the body. The Egyptian Atomic Energy Authority runs an extensive personal dosimetry service in Egypt, but finger doses have not been measured to a wide extent. In this study, the finger doses were measured for five different nuclear medicine staff occupational groups for which heavy irradiation of the hands was suspected. Finger doses were measured for nuclear medicine physicians, technologists, nurses and physicists. The nuclear medicine staff working with the radioactive materials wears two TLD dosimeters during the whole period, which lasted from 1 to 4 weeks. The staff performs their work on a regular basis throughout the month, and means annual doses were calculated for these groups. The doses to the fingers for the 99m Tc technologists and nurses of groups (2) and (3) were observed to be 30.24 ± 14.5 μSv/GBq (mean ± SD) and 30.37 ± 17.5 μSv/GBq, respectively. Similarly, the dose to the fingers for the 131 I technologists in group (5) was estimated to be 126.13 ± 38.2μSv/GBq. Finger doses for the physicians could not be calculated per unit of activity because they did not handle the radiopharmaceuticals directly but their doses were reported in millisieverts that accumulated in 1 week. The doses to the fingers of the physicist were 16.3±7.7 μSv/GBq. The maximum average finger dose in this study was found to be 2.8 mSv for the technologists handled therapeutic 131 I (group 5). It could be concluded that the maximum expected annual dose to the extremities appeared to be less than the annual limit (500 mSv/y).

  12. Assessment of dose measurement uncertainty using RisoScan

    International Nuclear Information System (INIS)

    Helt-Hansen, Jakob; Miller, Arne

    2006-01-01

    The dose measurement uncertainty of the dosimeter system RisoScan, office scanner and Riso B3 dosimeters has been assessed by comparison with spectrophotometer measurements of the same dosimeters. The reproducibility and the combined uncertainty were found to be approximately 2% and 4%, respectively, at one standard deviation. The subroutine in RisoScan for electron energy measurement is shown to give results that are equivalent to the measurements with a scanning spectrophotometer

  13. Some measurements of doses to patients from dental X-rays

    International Nuclear Information System (INIS)

    Woehni, T.

    1976-01-01

    Some measurements of doses to patients from conventional dental radiography and orthopantomography are presented. Doses to the red bone marrow are calculated. The bone marrow doses from two different exposures, Maxilla incisor and Molar bite-wing, were calculated to be 0.4 and 1.0 mrad respectively. The average dose to red bone marrow from a full-mouth examination (10 exposures) was 0.7 mrad/exposure. An orthopantomographic examination involved 2 mrad to the bone marrow. The greatest doses from an orthopantomographic examination were found around the lateral rotational axis, namely 700 mrad. The dose distributions from the two different cone lengths did not differ as much as expected, mainly due to scattered radiation. (Auth.)

  14. Some measurements of doses to patients from dental X-rays

    Energy Technology Data Exchange (ETDEWEB)

    Woehni, T [Statens Institutt for Straalehygiene, Oslo (Norway)

    1976-11-01

    Some measurements of doses to patients from conventional dental radiography and orthopantomography are presented. Doses to the red bone marrow are calculated. The bone marrow doses from two different exposures, Maxilla incisor and Molar bite-wing, were calculated to be 0.4 and 1.0 mrad respectively. The average dose to red bone marrow from a full-mouth examination (10 exposures) was 0.7 mrad/exposure. An orthopantomographic examination involved 2 mrad to the bone marrow. The greatest doses from an orthopantomographic examination were found around the lateral rotational axis, namely 700 mrad. The dose distributions from the two different cone lengths did not differ as much as expected, mainly due to scattered radiation.

  15. Measurement of patient radiation doses in certain urography procedures

    International Nuclear Information System (INIS)

    Sulieman, A.; Barakat, H.; Zailae, A.; Abuderman, A.; Theodorou, K.

    2015-01-01

    Patients are exposed to significant radiation doses during diagnostic and interventional urological procedures. This study aimed to measure patient entrance surface air kerma (ESAK) and to estimate the effective dose during intravenous urography (IVU), extracorporeal shock-wave lithotripsy (ESWL), and ascending urethrogram (ASU) procedures. ESAK was measured in patients using calibrated thermo luminance dosimeters, GR200A). Effective doses (E) were calculated using the National Radiological Protection Board (NRPB) software. A total of 179 procedures were investigated. 27.9 % of the patients underwent IVU procedures, 27.9 % underwent ESWL procedures and 44.2 % underwent ASU procedures. The mean ESAK was 2.1, 4.18 and 4.9 mGy for IVU, ESWL, and ASU procedures, respectively. Differences in patient ESAK for the same procedure were observed. The mean ESAK values were comparable with those in previous studies. (authors)

  16. Effects of gamma radiation on faba bean seed beetle Bruchus Dentipes Bande

    International Nuclear Information System (INIS)

    Mansour, Mohammed; Al-Bachir, Mahfouz

    1993-04-01

    Faba bean, Vivia bata, is one of the most important agricultural legume plants in Syria. Like any other crop, it is attacked by several insect pests. The most important of these is the faba bean seed beetle, Bruchus Dentipes Baudi. Infestation occurs only in the field and the major source of infestation is infested seed used for planting. The average infestation rate is about 45% and this reduces the economic value of the seeds to less than 50%. Chemical control in the field is effective but too expensive. Treating seeds in storage with fumigants is not as effective as it used to be, probably because of the pest developing resistance. Biological control has been investigated but their is no practically acceptable biological control agent at present. The lack of an effective biological control agent and/or economically acceptable and environmentally sound chemical control has led us to investigate the possibility of using gamma radiation to disinfest faba bean seeds as soon as possible after harvest when the insect is still in its early development stages. Infested faba bean seeds were treated immediately after harvest with 4 levels of gamma radiation ranged from 30 to 120 Gy with 30 Gy intervals. Treatment was repeated 15 and 30 days later and the effect of gamma radiation on larval survival was evaluated. The results showed that 90 Gy was sufficient to stop larval development and cause a 100% mortality. This dose, however, affected negatively seed germination. These results indicate that it is possible to disinfest faba bean seeds stored for human consumption with 90 Gy of gamma radiation. However, seeds destined for planting can not be treated with this dose. (author). 35 refs., 6 tabs., 2 figs

  17. Phantom measurements and computed estimates of breast dose with radiotherapy for Hodgkin's lymphoma: dose reduction with the use of the involved field

    International Nuclear Information System (INIS)

    Wirth, A.; Kron, T.; Sorell, G.; Cramb, J.; Wittwer, H.; Sullivan, K.

    2008-01-01

    Full text: The risk of breast cancer following radiotherapy for Hodgkin's lymphoma appears to be dose related. In this study we compared breast dose in an anthropomorphic phantom for conventional 'mantle'; upper mediastinal/bilateral neck (minimantle) and unilateral neck fields, and evaluated the accuracy of computer planned dose estimates for out-of-field doses. For each field, computer-planned breast dose (CPD) estimates were compared with thermolu-minescence dosimetry measurements in five locations within 'breast tissue'. CPD were also compared with ion chamber measurements in a slab phantom. Measured dose and CPD were within 20% of each other up to approximately 10 cm from the field edge. Beyond 10 cm, the CPD underestimated dose by a factor of 2 or more. The minimantle reduced the breast dose by a factor of approximately 10 compared with the mantle treatment. Treating the neck field lowered the breast dose by a further 50% or more. Modern involved-field radiotherapy for lymphoma substantially reduces breast dose compared with mantle fields. Computer dosimetery underestimated dose at larger distances from the field. This needs to be considered if computer dosimetery is used to estimate breast dose and, by extrapolation, breast cancer risk.

  18. Neutron and gamma dose and spectra measurements on the Little Boy replica

    International Nuclear Information System (INIS)

    Hoots, S.; Wadsworth, D.

    1984-01-01

    The radiation-measurement team of the Weapons Engineering Division at Lawrence Livermore National Laboratory (LLNL) measured neutron and gamma dose and spectra on the Little Boy replica at Los Alamos National Laboratory (LANL) in April 1983. This assembly is a replica of the gun-type atomic bomb exploded over Hiroshima in 1945. These measurements support the National Academy of Sciences Program to reassess the radiation doses due to atomic bomb explosions in Japan. Specifically, the following types of information were important: neutron spectra as a function of geometry, gamma to neutron dose ratios out to 1.5 km, and neutron attenuation in the atmosphere. We measured neutron and gamma dose/fission from close-in to a kilometer out, and neutron and gamma spectra at 90 and 30 0 close-in. This paper describes these measurements and the results. 12 references, 13 figures, 5 tables

  19. Real-time personal dose measurement and management system

    International Nuclear Information System (INIS)

    Zhang Zhiyong; Cheng Chang; Liu Zhengshan; Yang Huating; Deng Changming; Zhang Xiu; Guo Zhanjie

    2001-01-01

    The composition and design of a real-time personal dose measurement and management system are described. Accordingly, some pertinent hardware circuits and software codes including their operation modes are presented

  20. Epoxy resins used to seal brachytherapy seed

    International Nuclear Information System (INIS)

    Ferreira, Natalia Carolina Camargos; Ferraz, Wilmar Barbosa; Reis, Sergio Carneiro dos; Santos, Ana Maria Matildes dos

    2013-01-01

    Prostate cancer treatment with brachytherapy is recommended for patients with cancer at an early stage. In this treatment, small radioactive seeds are implanted directly in the prostate gland. These seeds are composed at least of one radionuclide carrier and an X-ray marker enclosed within a metallic tube usually sealed by laser process. This process is expensive and, furthermore, it can provoke a partial volatilization of the radionuclide and change the isotropy in dose distribution around the seed. In this paper, we present a new sealing process using epoxy resin. Three kinds of resins were utilized and characterized by scanning electron microscopy (SEM), energy dispersive X ray (EDS) and by differential scanning calorimetry (DSC) after immersion in simulated body fluid (SBF) and in sodium iodine solution (NaI). The sealing process showed excellent potential to replace the sealing laser usually employed. (author)

  1. Measurement of exposure dose rate by TLD in 60Co garden

    International Nuclear Information System (INIS)

    Fan Chengfang; Li Pinfang; Wu Maoliang; Zhao Quan

    1987-01-01

    The use of TLD method to measure exposure dose rate in 60 Co garden is described. As compared with chemical dosimetry, the relative deviation of measurement would not exceed 10%. The good repeatability has been proved by comparing the measurements of different times and distances with correction of decay law and 1/1 2 law. Besides, the distribution of exposure dose rate was influenced by scattering of the living plants

  2. Indoor gamma dose measurements in Gudalore (India) using TLD

    Energy Technology Data Exchange (ETDEWEB)

    Sivakumar, R.; Selvasekarapandian, S. E-mail: spandian@bharathi.ernet.in; Mugunthamanikandan, N.; Raghunath, V.M

    2002-06-01

    Indoor gamma radiation dose rates were measured inside residential buildings in Gudalore using a CaSO{sub 4} : Dy thermoluminescent dosimeter for 1 year . Significant seasonal variations are observed. The highest dose rate is observed during summer and the lowest in winter. The dose rates observed are between 77.9 and 229.3 nGy h{sup -1} and may be attributed to the type of building materials used in the dwellings monitored. The calculated mean annual effective dose equivalent rates range between 477.6 {mu}Sv y{sup -1}, for the inhabitants of mud houses to 1406.3 {mu}Sv y{sup -1}, for those living in terrace houses made of cement and brick.

  3. Determination of degradability of germinated and heated soybean seeds and its proteins fractions

    Directory of Open Access Journals (Sweden)

    Behruz Alizadeh

    2016-09-01

    Full Text Available A study on the sensitivity of watermelon variety Bojura to mutagenic agents was carried out in 2013-2014. The goal was to establish effective doses for mutagenic treatment of dry seeds with 60Co gamma rays (80, 100, 200, 250, 350 and 450 Gy and swollen seeds with water for 24 hours were treated with ethyl methanesulfonate (EMS at a concentration of 2%. Dominant mutations were not observed in the M1 generation. Morphological changes in 14 of 1395 M2 plants were observed. Phenotypic variations changes were the colour of the seed coat, chlorophyll disorders of cotyledons, leaves, petals, and alterations of the location of the fruit set in the central stem. Visible changes of the morphological characteristics of the fruit were not observed. The doses induced certain morphological changes, however, higher doses or combined gamma rays 60Co and EMS treatments would induce mutations more efficiently. Subsequent experiments are required to obtain mutants with changes that affect flowers and fruits. The results are important for increasing mutation efficiency in watermelon breeding.

  4. Delivered dose uncertainty analysis at the tumor apex for ocular brachytherapy

    Energy Technology Data Exchange (ETDEWEB)

    Morrison, Hali, E-mail: hamorris@ualberta.ca; Menon, Geetha; Larocque, Matthew P.; Jans, Hans-Sonke; Sloboda, Ron S. [Department of Medical Physics, Cross Cancer Institute, Edmonton, Alberta T6G 1Z2, Canada and Department of Oncology, University of Alberta, Edmonton, Alberta T6G 2R3 (Canada); Weis, Ezekiel [Department of Ophthalmology, University of Alberta, Edmonton, Alberta T6G 2R3 (Canada)

    2016-08-15

    Purpose: To estimate the total dosimetric uncertainty at the tumor apex for ocular brachytherapy treatments delivered using 16 mm Collaborative Ocular Melanoma Study (COMS) and Super9 plaques loaded with {sup 125}I seeds in order to determine the size of the apex margin that would be required to ensure adequate dosimetric coverage of the tumor. Methods: The total dosimetric uncertainty was assessed for three reference tumor heights: 3, 5, and 10 mm, using the Guide to the expression of Uncertainty in Measurement/National Institute of Standards and Technology approach. Uncertainties pertaining to seed construction, source strength, plaque assembly, treatment planning calculations, tumor height measurement, plaque placement, and plaque tilt for a simple dome-shaped tumor were investigated and quantified to estimate the total dosimetric uncertainty at the tumor apex. Uncertainties in seed construction were determined using EBT3 Gafchromic film measurements around single seeds, plaque assembly uncertainties were determined using high resolution microCT scanning of loaded plaques to measure seed positions in the plaques, and all other uncertainties were determined from the previously published studies and recommended values. All dose calculations were performed using PLAQUESIMULATOR v5.7.6 ophthalmic treatment planning system with the inclusion of plaque heterogeneity corrections. Results: The total dosimetric uncertainties at 3, 5, and 10 mm tumor heights for the 16 mm COMS plaque were 17.3%, 16.1%, and 14.2%, respectively, and for the Super9 plaque were 18.2%, 14.4%, and 13.1%, respectively (all values with coverage factor k = 2). The apex margins at 3, 5, and 10 mm tumor heights required to adequately account for these uncertainties were 1.3, 1.3, and 1.4 mm, respectively, for the 16 mm COMS plaque, and 1.8, 1.4, and 1.2 mm, respectively, for the Super9 plaque. These uncertainties and associated margins are dependent on the dose gradient at the given prescription

  5. SENSITIVITY OF THE CUMIN SEEDS ASSOCIATED FUNGI TO GAMMA RADIATION

    International Nuclear Information System (INIS)

    BOTROS, H.W.; HELAL, I.M.; EL TOBGY, K.M.K.

    2008-01-01

    The present study was carried out to investigate the sensitivity of fungi associated to cumin seeds for gamma radiation. In this regard, the isolated seed associated fungi from the cumin seeds were fifteen fungal species belonging to five genera. The fungal species concerning, Aspergillus ochraceus, Fusarium oxysporium and Aspergillus flavus were the predominant fungi in percentages of 17.8, 15.83 and 12.78 %, respectively. Aspergillus ochraceus was the most effective prevalent fungi on the seed germination causing highest percentage of seed invasion followed by Fusarium oxysporium and Aspergillus flavus. The amylolytic, proteolytic and lipolytic activity and mycotoxin production of the three predominant fungi were negatively influenced by gamma radiation when exposed to doses of 1.0 , 1.5 , 2.5 , 3.5 , 5.0 and 7.5 kGy a behaviour which was parallel to the inhibition in the amount of growth by gamma irradiation

  6. Organ dose evaluation for CT scans based on in-phantom measurements

    International Nuclear Information System (INIS)

    Liu Haikuan; Zhuo Weihai; Chen Bo; Yi Yanling; Li Dehong

    2009-01-01

    Objective: To explore the organ doses and their distributions in different projections of CT scans. Methods: The CT values were measured and the linear absorption coefficients were derived for the main organs of the anthropomorphic phantom to compare with the normal values of human beings. The radiophotoluminescent glass dosimeters were set into various tissues or organs of the phantom for mimic measurements of the organ doses undergoing the head, chest, abdomen and pelvis CT scans, respectively. Results: The tissue equivalence of the phantom used in this study was good. The brain had the largest organ dose undergoing the head CT scan. The organ doses in thyroid, breast, lung and oesophagus were relatively large in performing the chest CT scan, while the liver, stomach, colon and lung had relatively hrge organ doses in abdomen CT practice. The doses in bone surface and colon exceeded by 50 mGy in a single pelvis CT scan. Conclusions: The organ doses and their distributions largely vary with different projections of CT scans. The organ doses of colon, bone marrow,gonads and bladder are fairly large in performing pelvis CT scan, which should be paid attention in the practice. (authors)

  7. Polystyrene calorimeter for electron beam dose measurements

    DEFF Research Database (Denmark)

    Miller, A.

    1995-01-01

    Calorimeters from polystrene have been constructed for dose measurement at 4-10 MeV electron accelerators. These calorimeters have been used successfully for a few years, and polystyrene calorimeters for use at energies down to 1 MeV and being tested. Advantage of polystyrene as the absorbing...

  8. Radiation dose measurements during kilovoltage-cone beam computed tomography imaging in radiotherapy

    Directory of Open Access Journals (Sweden)

    A Sathish Kumar

    2016-01-01

    Conclusion: Radiation dose to the eye, breast, and the surface of the pelvis have been arrived at during CBCT. The doses measured on patients agreed closely with those measured on humanoid phantom and with published values.

  9. DOSES DE EXTRATO DE PRÓPOLIS NO CONTROLE DO FUNGO Aspergillus sp E NO TRATAMENTO DE SEMENTES DE PEPINO / EXTRACT OF PROPOLIS IN THE TREATMENT OF CUCUMBER SEEDS AND CONTROL OF Aspergillus sp

    Directory of Open Access Journals (Sweden)

    E.P. de Souza

    2017-12-01

    Full Text Available The alternative control has as characteristics the absence of contamination and social and environmental toxicity, and an alternative is the extract of propolis, which objectified with this work verify the effect of solutions of propolis extract in vitro control of the fungus Aspergillus sp, and the physiological quality of the cucumber seeds after treatment with the same solutions. Isolate from the fungus was inoculated in BDA medium with concentrations of 0; 8; 12; 18 and 25% of aqueous Propamax® extract, totaling five treatments. For the seed treatment, were used the same concentrations of propolis extract. The design was completely randomized with six replicates. It was verified that with the linear increase of the dose of the propolis extract, there was interference in the fungus development reaching maximum with 25%. Cucumber seeds treated with propolis solutions do not affect the physiological quality, resulting in a possible alternative seed treatment.

  10. Ozone dose-response relationships for spring oilseed rape and broccoli

    Science.gov (United States)

    De Bock, Maarten; Op de Beeck, Maarten; De Temmerman, Ludwig; Guisez, Yves; Ceulemans, Reinhart; Vandermeiren, Karine

    2011-03-01

    Tropospheric ozone is an important air pollutant with known detrimental effects for several crops. Ozone effects on seed yield, oil percentage, oil yield and 1000 seed weight were examined for spring oilseed rape ( Brassica napus cv. Ability). For broccoli ( Brassica oleracea L. cv. Italica cv. Monaco) the effects on fresh marketable weight and total dry weight were studied. Current ozone levels were compared with an increase of 20 and 40 ppb during 8 h per day, over the entire growing season. Oilseed rape seed yield was negatively correlated with ozone dose indices calculated from emergence until harvest. This resulted in an R2 of 0.24 and 0.26 ( p broccoli the applied ozone doses had no effect on yield.

  11. Effects of seed migration on post-implant dosimetry of prostate brachytherapy

    International Nuclear Information System (INIS)

    Gao, M.; Wang, J. Z.; Nag, S.; Gupta, N.

    2007-01-01

    Brachytherapy using permanent seed implants has been an effective treatment for prostate cancer. However, seeds will migrate after implant, thus making the evaluation of post-implant dosimetry difficult. In this study, we developed a computer program to simulate seed migration and analyzed dosimetric changes due to seed migration at various migration amounts. The study was based on 14 patients treated with Pd-103 at the James Cancer Hospital. Modeling of seed migration, including direction, distance as well as day of migration, was based on clinical observations. Changes of commonly used dosimetric parameters as a function of migration amount (2, 4, 6 mm respectively), prostate size (from 20 to 90 cc), and prostate region (central vs peripheral) were studied. Change of biological outcome (tumor control probability) due to migration was also estimated. Migration reduced prostate D90 to 99±2% of original value in 2 mm migration, and the reduction increased to 94±6% in 6 mm migration. The reduction of prostate dose led to a 14% (40%) drop in the tumor control probability for 2 mm (6 mm) migration, assuming radiosensitive tumors. However, migration has less effect on a prostate implanted with a larger number of seeds. Prostate V100 was less sensitive to migration than D90 since its mean value was still 99% of original value even in 6 mm migration. Migration also showed a different effect in the peripheral region vs the central region of the prostate, where the peripheral mean dose tended to drop more significantly. Therefore, extra activity implanted in the peripheral region during pre-plan can be considered. The detrimental effects of migration were more severe in terms of increasing the dose to normal structures, as rectum V50 may be 70% higher and urethra V100 may be 50% higher in the case of 6 mm migration. Quantitative knowledge of these effects is helpful in treatment planning and post-implant evaluation

  12. Effect of gamma radiation on growth and survival of common seed-borne fungi in India

    Energy Technology Data Exchange (ETDEWEB)

    Maity, J.P. [Department of Environmental Science, University of Kalyani, Nadia 741235, WB (India); Department of Atomic Energy Consortium for Scientific Research, University Grant Commission, Kolkata Center, 3/LB-8, Salt Lake, Kolkata 700098 (India); Center for Study of Man and Environment, CK-11, Sector-II, Kolkata 700091 (India)], E-mail: jyoti_maity@yahoo.com; Chakraborty, A. [Department of Atomic Energy Consortium for Scientific Research, University Grant Commission, Kolkata Center, 3/LB-8, Salt Lake, Kolkata 700098 (India); Chanda, S. [Center for Study of Man and Environment, CK-11, Sector-II, Kolkata 700091 (India); Santra, S.C. [Department of Environmental Science, University of Kalyani, Nadia 741235, WB (India)

    2008-07-15

    The present work describes radiation-induced effects of major seeds like Oryza sativa Cv-2233, Oryza sativa Cv-Shankar, Cicer arietinum Cv-local and seed-borne fungi like Alternaria sp., Aspergillus sp., Trichoderma sp. and Curvularia sp. {sup 60}Co gamma source at 25 deg. C emitting gamma ray at 1173 and 1332 keV energy was used for irradiation. Dose of gamma irradiation up to 3 kGy (0.12 kGy/h) was applied for exposing the seed and fungal spores. Significant depletion of the fungal population was noted with irradiation at 1-2 kGy, whereas germinating potential of the treated grain did not alter significantly. However, significant differential radiation response in delayed seed germination, colony formation of the fungal spores and their depletion of growth were noticed in a dose-dependent manner. The depletion of the fungal viability (germination) was noted within the irradiation dose range of 1-2 kGy for Alternaria sp. and Aspergillus sp., while 0.5-1 kGy for Trichoderma sp. and Curvularia sp. However, complete inhibition of all the selected fungi was observed above 2.5 kGy.

  13. Effect of gamma radiation on growth and survival of common seed-borne fungi in India

    International Nuclear Information System (INIS)

    Maity, J.P.; Chakraborty, A.; Chanda, S.; Santra, S.C.

    2008-01-01

    The present work describes radiation-induced effects of major seeds like Oryza sativa Cv-2233, Oryza sativa Cv-Shankar, Cicer arietinum Cv-local and seed-borne fungi like Alternaria sp., Aspergillus sp., Trichoderma sp. and Curvularia sp. 60 Co gamma source at 25 deg. C emitting gamma ray at 1173 and 1332 keV energy was used for irradiation. Dose of gamma irradiation up to 3 kGy (0.12 kGy/h) was applied for exposing the seed and fungal spores. Significant depletion of the fungal population was noted with irradiation at 1-2 kGy, whereas germinating potential of the treated grain did not alter significantly. However, significant differential radiation response in delayed seed germination, colony formation of the fungal spores and their depletion of growth were noticed in a dose-dependent manner. The depletion of the fungal viability (germination) was noted within the irradiation dose range of 1-2 kGy for Alternaria sp. and Aspergillus sp., while 0.5-1 kGy for Trichoderma sp. and Curvularia sp. However, complete inhibition of all the selected fungi was observed above 2.5 kGy

  14. Electron spin resonance (ESR) studies on irradiated cocoa beans and niger seeds

    International Nuclear Information System (INIS)

    Mangaonkar, S.R.; Natarajan, V.; Sastry, M.D.; Desai, S.R.P.; Kulkarni, P.R.

    1997-01-01

    Electron spin resonance (ESR) spectra of irradiated (10kGy) and unirradiated cocoa beans and niger seeds have been compared. Unirradiated cocoa beans failed to give any ESR signal, whereas after irradiation (10kGy) an ESR signal at g = 2.0042 was observed. However, ESR signals are given by both irradiated and unirradiated niger seeds. The intensity of signal was found to be dose-dependent up to 10kGy for both seeds. The signals were stable up to 180 days in both cases. The results indicate the possibility of using ESR for distinguishing between irradiated and unirradiated cocoa beans but not for niger seeds

  15. EPR spin probe investigation of irradiated wheat, rice and sunflower seeds

    Energy Technology Data Exchange (ETDEWEB)

    Paktas, Dilek Dadayl [Department of Physics, Faculty of Art and Science, Zonguldak Karaelmas University, 67100 Zonguldak (Turkey)]. E-mail: dadayli@karaelmas.edu.tr; Suennetcioglu, M. Maral [Department of Physics Engineering, Hacettepe University, 06532 Beytepe, Ankara (Turkey)

    2007-01-15

    TEMPO and 4-nitro-TEMPO spin probes were used to monitor dose-dependent changes in the EPR spectra of irradiated wheat and rice embryos and sunflower embryo parts. Rice embryos were studied in the 233-293 K temperature range using 4-nitro-TEMPO. TEMPAMINE, TEMPYO and DTBN spin probes were also studied for their applicability in the determination of irradiated seeds. All the recorded spectra were simulated, and spectral parameters and partition of the probes among various domains were determined. Despite the contribution of the signal from extracellular regions, it was possible to detect the changes in the water/lipid ratios with dose. The hydrophilic character of the probe alone was not sufficient to distinguish the different doses of irradiation. Line widths and rotational correlation times of various domains within embryo also play an important role. Partition after dehydration was another measure in the selection of the suitable probes for irradiation studies. Better results were obtained in dehydrated embryos for the probes preferring lipid bodies.

  16. Pediatric patient and staff dose measurements in barium meal fluoroscopic procedures

    Science.gov (United States)

    Filipov, D.; Schelin, H. R.; Denyak, V.; Paschuk, S. A.; Porto, L. E.; Ledesma, J. A.; Nascimento, E. X.; Legnani, A.; Andrade, M. E. A.; Khoury, H. J.

    2015-11-01

    This study investigates patient and staff dose measurements in pediatric barium meal series fluoroscopic procedures. It aims to analyze radiographic techniques, measure the air kerma-area product (PKA), and estimate the staff's eye lens, thyroid and hands equivalent doses. The procedures of 41 patients were studied, and PKA values were calculated using LiF:Mg,Ti thermoluminescent dosimeters (TLDs) positioned at the center of the patient's upper chest. Furthermore, LiF:Mg,Cu,P TLDs were used to estimate the equivalent doses. The results showed a discrepancy in the radiographic techniques when compared to the European Commission recommendations. Half of the results of the analyzed literature presented lower PKA and dose reference level values than the present study. The staff's equivalent doses strongly depends on the distance from the beam. A 55-cm distance can be considered satisfactory. However, a distance decrease of ~20% leads to, at least, two times higher equivalent doses. For eye lenses this dose is significantly greater than the annual limit set by the International Commission on Radiological Protection. In addition, the occupational doses were found to be much higher than in the literature. Changing the used radiographic techniques to the ones recommended by the European Communities, it is expected to achieve lower PKA values ​​and occupational doses.

  17. DNA comet assay for rice seeds treated with low energy electrons ('soft-electrons')

    International Nuclear Information System (INIS)

    Todoriki, Setsuko; Hayashi, Toru

    1999-01-01

    As rice seeds are sometimes contaminated with phytopathogenic organisms such as blast disease fungi and nematodes, a novel non-chemical disinfection method for rice seeds is highly required. In order to develop a disinfection method, the effect of low energy electron ('soft-electrons') on seed DNA was examined by using the neutral comet assay. Rice seeds (whole grain) were treated with electrons of different acceleration voltages (180 kV to 1 MV) at a dose of 5 kGy. Nucleus suspensions were prepared from whole brown rice and subjected to electrophoresis. DNA from un-irradiated (control) seeds relaxed and produced comets with a short tail, most of the comets distributed within the range of comet length between 30 μm to 70 μm. In the case of seeds treated with electrons at acceleration voltages up to 190 kV, cells without seed coats were not damaged and the frequency histograms of comet length showed almost the same pattern as that for control. At acceleration voltages higher than 200 kV, the cells were distributed into two categories; DNA comets with a short tail (with little DNA damages, less than 70 μm in the comet length) and DNA comets with long tails (with sever strand breaks, more than 130 μm in the comet length). The ratios of damaged cells increased with increasing acceleration voltage. The growths of rice seedlings were not affected by the treatment with electrons at up to 200 kV. On the contrary, the cells of gamma-irradiated seed showed small variations in the comet length, and which were depending on radiation dose. The individual cells of gamma-irradiated seeds at 1 kGy showed shorter comet than the damaged cells with soft electron, seed treated with gamma rays (1-5 kGy) did not shoot nor root. (author)

  18. Multilayer detector for skin absorbed dose measuring

    International Nuclear Information System (INIS)

    Osanov, D.P.; Panova, V.P.; Shaks, A.I.

    1985-01-01

    A method for skin dosimetry based on utilization of multilayer detectors and permitting to estimate distribution of absorbed dose by skin depth is described. The detector represents a set of thin sensitive elements separated by tissue-equivalent absorbers. Quantitative evaluation and forecasting the degree of radiation injury of skin are determined by the formula based on determination of the probability of the fact that cells are not destroyed and they can divide further on. The given method ensures a possibility of quantitative evaluation of radiobiological effect and forecasting clinical consequences of skin irradiation by results of corresponding measurements of dose by means of the miultilayer detector

  19. Composite depth dose measurement for total skin electron (TSE) treatments using radiochromic film

    International Nuclear Information System (INIS)

    Gamble, Lisa M; Farrell, Thomas J; Jones, Glenn W; Hayward, Joseph E

    2003-01-01

    Total skin electron (TSE) radiotherapy is routinely used to treat cutaneous T-cell lymphomas and can be implemented using a modified Stanford technique. In our centre, the composite depth dose for this technique is achieved by a combination of two patient positions per day over a three-day cycle, and two gantry angles per patient position. Due to patient morphology, underdosed regions typically occur and have historically been measured using multiple thermoluminescent dosimeters (TLDs). We show that radiochromic film can be used as a two-dimensional relative dosimeter to measure the percent depth dose in TSE radiotherapy. Composite depth dose curves were measured in a cylindrical, polystyrene phantom and compared with TLD data. Both multiple films (1 film per day) and a single film were used in order to reproduce a realistic clinical scenario. First, three individual films were used to measure the depth dose, one per treatment day, and then compared with TLD data; this comparison showed a reasonable agreement. Secondly, a single film was used to measure the dose delivered over three daily treatments and then compared with TLD data; this comparison showed good agreement throughout the depth dose, which includes doses well below 1 Gy. It will be shown that one piece of radiochromic film is sufficient to measure the composite percent depth dose for a TSE beam, hence making radiochromic film a suitable candidate for monitoring underdosed patient regions

  20. Neutron dose measurements with the GSI ball at high energy accelerators

    International Nuclear Information System (INIS)

    Fehrenbacher, G.; Gutermuth, F.; Radon, T.; Kozlova, E.

    2005-01-01

    Full text: At high energy particle accelerators the production of neutron radiation dominates radiation protection. For the radiation survey at accelerators there is a need for reliable detection systems (passive radiation monitors), which can measure the dose for a wide range of neutron energies independently on the beam pulse structure of the produced radiation. In this work a passive neutron dosemeter for the measurement of the ambient dose equivalent is presented. The dosemeter is suitable for measurements of the emerging neutron radiation at accelerators for the whole energy range up to about 10 GeV. The dosemeter consists of a polyethylene sphere, TL elements (pairs of TLD600/700) and an additional lead layer (PE/Pb) in neutron fields at high energy accelerators is investigated in this work. Results of dose measurements which were performed in realistic neutron fields at the high energy accelerator SPS at CERN (CERF facility) and in Cave A at the heavy ion synchrotron SIS at GSI are presented. The results of these measurements are compared with the expected dose values from the neutron spectra determined for the measurement positions at CERF and in Cave A (FLUKA) and with the dosemeter response derived by the calculated response functions (FLUKA) folded with the neutron spectra. The comparisons show that the additional lead layer in the PE/Pb-sphere improves significantly the response of the dosemeter. The response of the PE/Pb-sphere is 40 to 50 % higher at CERF and Cave A in comparison to the bare PE-sphere. At CERF the dose values of the PE/Pb-sphere is about 25 % lower than the expected dose value, whilst for Cave A, a rather good agreement was found (2 % deviation). (author)

  1. ESR analysis of natural and gamma irradiated coriander (Coriandrum sativum L.) seeds

    Science.gov (United States)

    Sezer, M. Özgür; Kaplan, Necati; Sayin, Ulku

    2017-12-01

    Electron spin resonance (ESR) is a powerful technique to detect radicals trapped in cellulosic food products and has been suggested as a useful method for identification of irradiated herbal foodstuffs. Coriander spice which has important medicinal properties was investigated using ESR spectroscopy. Radicals in natural and irradiated coriander samples were determined at room temperature. ESR spectra of natural sample were characterized by a single central signal with ? value and gamma irradiation produced satellite peaks attributed to cellulose-like radical which is used as a marker for detection of irradiated cellulosic plant products. The spectroscopic splitting values of radicals were determined. Dose dependency and stability of this center were analyzed by dose response and kinetic measurements. The reported results about activation energy, thermal life time and dose response relationship of the cellulose-like radical accurately prove that ESR can be used for identification of irradiated coriander spice seeds.

  2. Measurement of ambient dose equivalent H*(10) and directional dose equivalent H'(0.07) with pocket sized survey meters

    International Nuclear Information System (INIS)

    Iwatschenko, Michael

    2008-01-01

    Full text: In many parts of the world, predominantly in Europe, small sized survey meters based on Geiger-Mueller or proportional counters are widely used for dose rate and dose equivalent rate measurements, while in other regions, especially in the U.S., ionisation chambers are preferred for this task. This paper tries to shed some light on the likely reasons for these two diverging instrumental inclinations. Their respective strengths and weaknesses is analyzed in respect to energy response, dose rate measuring range, size, weight and susceptibility to environmental influences. Furthermore the response and limitations regarding the measurement of pulsed radiation (medical X-ray and CT-devices, accelerators, non-destructive testing) is discussed. A newly developed pocket size instrument based on a pan-cake Geiger-Mueller tube is used as an example to explain the capability and flexibility of modern survey meters. The RadEye B20 is a compact multi-purpose dose rate meter and contamination meter for alpha, beta, gamma and X-ray radiation. By virtue of carefully designed multi-layer gamma energy filters, H*(10) (deep dose) or H'(0,07) (shallow dose) measurements from 17 - 1300 keV can be performed. The instrument can even be worn in a belt holster, so that the impact to the mobility of the user is minimized. For emergency response purposes alpha and beta contamination can be discriminated using another optional filter; a simple sample changer adapter can extend the scope of application. Immediate and reproducible counter measurements, e.g. of smear tests can be performed locally. (author)

  3. Study on apoptosis of prostate cancer cell induced by 125I seed irradiation

    International Nuclear Information System (INIS)

    Liao Anyan; Wang Junjie; Wang Jidong; Zhuang Hongqing; Zhao Yong

    2007-01-01

    Objective: To explore the mechanism of apoptosis induced by 125 I seed irradiation on PC3 cells. Methods: Human prostate cancer cell line PC3 was treated by irradiation of 125 I (2.77 cGy/h) with various dose. Agarose gel electrophoresis of DNA and flows cytometry were used to detect the apoptosis of PC3 cells and indirect immunofluorescence assay was used to detect the expression of Bcl-2. The activity of Caspase-3 was measured by Caspase Colorimetric Assay Kits. Results: Apoptosis of PC3 cells could be efficiently induced by 125 I seed irradiation. The apoptotic peaks were found by flow cytometry and DNA ladder appeared on 1.8% agarose gel. The activity of Caspase-3 on PC3 cells treated by 125 I seed irradiation was not changed significantly. Bcl-2 gene expression was down-regulated with the sample concentration increased. Conclusion: 125 I irradiation can induce the apoptosis of PC3 cells and the mechanism of apoptosis is related with down regulation of Bcl-2 gene expression and is not related with Caspase-3 activity. (authors)

  4. The Antiproton Depth Dose Curve Measured with Alanine Detectors

    DEFF Research Database (Denmark)

    Bassler, Niels; Hansen, Johnny Witterseh; Palmans, Hugo

    2008-01-01

    In this paper we report on the measurement of the antiproton depth dose curve, with alanine detectors. The results are compared with simulations using the particle energy spectrum calculated by FLUKA, and using the track structure model of Hansen et Olsen for conversion of calculated dose...... into response. A good agreement was observed between the measured and calculated relative effectiveness although a slight underestimation of the calculated values in the Bragg peak remains unexplained. The model prediction of response of alanine towards heavy charged particles encourages future use...... of the alanine detectors for dosimetry of mixed radiation fields....

  5. Monte Carlo investigation of the dosimetric properties of the new 103Pd BrachySeedTMPd-103 Model Pd-1 source

    International Nuclear Information System (INIS)

    Chan, Gordon H.; Prestwich, William V.

    2002-01-01

    Recently, 103 Pd brachytherapy sources have been increasingly used for interstitial implants as an alternative to 125 I sources. The BrachySeed TM Pd-103 Model Pd-1 seed is one of the latest in a series of new brachytherapy sources that have become available commercially. The dosimetric properties of the seed were investigated by Monte Carlo simulation, which was performed using the Integrated Tiger Series CYLTRAN code. Following the AAPM Task Group 43 formalism, the dose rate constant, radial dose function, and anisotropy parameters were determined. The dose rate constant, Λ, was calculated to be 0.613±3% cGy h -1 U -1 . This air kerma strength was derived from Monte Carlo simulation using the point extrapolation method. The radial dose function, g(r), was computed at distances from 0.15 to 10 cm. The anisotropy function, F(r,θ), and anisotropy factor, φ an (r), were calculated at distances from 0.5 to 7 cm. The anisotropy constant, φ(bar sign) an , was determined to be 0.978, which is closer to unity than most other 103 Pd seeds, indicating a high degree of uniformity in dose distribution. The dose rate constant and the radial dose function were also investigated by analytical modeling, which served as an independent evaluation of the Monte Carlo data, and found to be in good agreement with the Monte Carlo results

  6. Methodic of the gamma-rays absorbed dose measurements on tooth enamel

    International Nuclear Information System (INIS)

    Linev, S.V.; Muravskij, V.A.; Mashevskij, A.A.; Ugolev, I.I.

    1997-01-01

    The analysis of the metrological aspects of the tooth enamel ESR dosimetry has been done. The sample preparation and measurement methods have been elaborated. The methods have passed metrological certification. The methods include tabletting of the mixture of tooth enamel powder and MnO paramagnetic centres concentration additional standard, two loops of additional irradiation of samples by 1 Gy dose and ESR-spectra measurements, calculation of absorbed dose by maximum likelihood algorithm. The algorithm of dose calculation uses enamel spectrum model with axial anisotropic spin-Hamiltonian based on 126 spectra of enamel samples. The algorithm takes into account spectra of the empty cavity, the tube for a sample, the glue and MnO standard. Certificated ESR-station is based on the ESR-analyser PS-100X. ESR-station provides tooth enamel absorbed dose measurements from 0.05 to 0.25 Gy with error 35%, and from 0.25 to 3 Gy with error 20%. The set of tooth enamel absorbed dose standard samples has been created and certificated for the purposes of ESR-station testing and certification. The set consists of 12 tabletted samples of tooth enamel irradiated by doses from 0.05 to 4 Gy. (authors). 7 refs., 1 tab., 2 figs

  7. A greedy heuristic using adjoint functions for the optimization of seed and needle configurations in prostate seed implant

    Energy Technology Data Exchange (ETDEWEB)

    Yoo, Sua [Department of Radiation Oncology, Duke University Medical Center, Box 3295, Durham, NC 27710 (United States); Kowalok, Michael E [Department of Radiation Oncology, Virginia Commonwealth University Health System, 401 College St., PO Box 980058, Richmond, VA 23298-0058 (United States); Thomadsen, Bruce R [Department of Medical Physics, University of Wisconsin-Madison, 1530 MSC, 1300 University Ave., Madison, WI 53706 (United States); Henderson, Douglass L [Department of Engineering Physics, University of Wisconsin-Madison, 153 Engineering Research Bldg., 1500 Engineering Dr., Madison, WI 53706 (United States)

    2007-02-07

    We continue our work on the development of an efficient treatment-planning algorithm for prostate seed implants by incorporation of an automated seed and needle configuration routine. The treatment-planning algorithm is based on region of interest (ROI) adjoint functions and a greedy heuristic. As defined in this work, the adjoint function of an ROI is the sensitivity of the average dose in the ROI to a unit-strength brachytherapy source at any seed position. The greedy heuristic uses a ratio of target and critical structure adjoint functions to rank seed positions according to their ability to irradiate the target ROI while sparing critical structure ROIs. Because seed positions are ranked in advance and because the greedy heuristic does not modify previously selected seed positions, the greedy heuristic constructs a complete seed configuration quickly. Isodose surface constraints determine the search space and the needle constraint limits the number of needles. This study additionally includes a methodology that scans possible combinations of these constraint values automatically. This automated selection scheme saves the user the effort of manually searching constraint values. With this method, clinically acceptable treatment plans are obtained in less than 2 min. For comparison, the branch-and-bound method used to solve a mixed integer-programming model took close to 2.5 h to arrive at a feasible solution. Both methods achieved good treatment plans, but the speedup provided by the greedy heuristic was a factor of approximately 100. This attribute makes this algorithm suitable for intra-operative real-time treatment planning.

  8. A greedy heuristic using adjoint functions for the optimization of seed and needle configurations in prostate seed implant

    International Nuclear Information System (INIS)

    Yoo, Sua; Kowalok, Michael E; Thomadsen, Bruce R; Henderson, Douglass L

    2007-01-01

    We continue our work on the development of an efficient treatment-planning algorithm for prostate seed implants by incorporation of an automated seed and needle configuration routine. The treatment-planning algorithm is based on region of interest (ROI) adjoint functions and a greedy heuristic. As defined in this work, the adjoint function of an ROI is the sensitivity of the average dose in the ROI to a unit-strength brachytherapy source at any seed position. The greedy heuristic uses a ratio of target and critical structure adjoint functions to rank seed positions according to their ability to irradiate the target ROI while sparing critical structure ROIs. Because seed positions are ranked in advance and because the greedy heuristic does not modify previously selected seed positions, the greedy heuristic constructs a complete seed configuration quickly. Isodose surface constraints determine the search space and the needle constraint limits the number of needles. This study additionally includes a methodology that scans possible combinations of these constraint values automatically. This automated selection scheme saves the user the effort of manually searching constraint values. With this method, clinically acceptable treatment plans are obtained in less than 2 min. For comparison, the branch-and-bound method used to solve a mixed integer-programming model took close to 2.5 h to arrive at a feasible solution. Both methods achieved good treatment plans, but the speedup provided by the greedy heuristic was a factor of approximately 100. This attribute makes this algorithm suitable for intra-operative real-time treatment planning

  9. Neutron dose and energy spectra measurements at Savannah River Plant

    International Nuclear Information System (INIS)

    Brackenbush, L.W.; Soldat, K.L.; Haggard, D.L.; Faust, L.G.; Tomeraasen, P.L.

    1987-08-01

    Because some workers have a high potential for significant neutron exposure, the Savannah River Plant (SRP) contracted with Pacific Northwest Laboratory (PNL) to verify the accuracy of neutron dosimetry at the plant. Energy spectrum and neutron dose measurements were made at the SRP calibrations laboratory and at several other locations. The energy spectra measurements were made using multisphere or Bonner sphere spectrometers, 3 He spectrometers, and NE-213 liquid scintillator spectrometers. Neutron dose equivalent determinations were made using these instruments and others specifically designed to determine dose equivalent, such as the tissue equivalent proportional counter (TEPC). Survey instruments, such as the Eberline PNR-4, and the thermoluminescent dosimeter (TLD)-albedo and track etch dosimeters (TEDs) were also used. The TEPC, subjectively judged to provide the most accurate estimation of true dose equivalent, was used as the reference for comparison with other devices. 29 refs., 43 figs., 13 tabs

  10. Effect of dose of gamma-rays and ethylmethane sulphonate on the germination and survival of induced mutations in pigeonpea

    Energy Technology Data Exchange (ETDEWEB)

    Premsekar, S [Central Inst. for Cotton Research, Coimbatore (India). Regional Station; Appadurai, R [Tamil Nadu Agricultural Univ., Coimbatore (India)

    1981-06-01

    The LD/sub 50/ values for germination and survival of the induced mutants (M/sub 1/) of pigeonpea (Cajanus cajan (Linn.) Millsp.) were attained with 20 and 15 krad when gamma-rays were used, and 30 and 40 mM concentration when EMS was used. In the combination treatments the half-kill dose for germination and survival was reached even at the low dose combination of 5 krad gamma-ray + 20 mM EMS. Higher doses resulted in lower pollen and seed fertility. The sterility was much enhanced in the combined treatments. The number of pods, seed yield and weight of seeds could be stimulated with 10 and 15 krad doses of gamma-rays and 20 mM of EMS. In combination treatments such a stimulatory effect was noticed in seed weight only.

  11. Systematic measurements of whole-body imaging dose distributions in image-guided radiation therapy

    International Nuclear Information System (INIS)

    Hälg, Roger A.; Besserer, Jürgen; Schneider, Uwe

    2012-01-01

    Purpose: The full benefit of the increased precision of contemporary treatment techniques can only be exploited if the accuracy of the patient positioning is guaranteed. Therefore, more and more imaging modalities are used in the process of the patient setup in clinical routine of radiation therapy. The improved accuracy in patient positioning, however, results in additional dose contributions to the integral patient dose. To quantify this, absorbed dose measurements from typical imaging procedures involved in an image-guided radiation therapy treatment were measured in an anthropomorphic phantom for a complete course of treatment. The experimental setup, including the measurement positions in the phantom, was exactly the same as in a preceding study of radiotherapy stray dose measurements. This allows a direct combination of imaging dose distributions with the therapy dose distribution. Methods: Individually calibrated thermoluminescent dosimeters were used to measure absorbed dose in an anthropomorphic phantom at 184 locations. The dose distributions from imaging devices used with treatment machines from the manufacturers Accuray, Elekta, Siemens, and Varian and from computed tomography scanners from GE Healthcare were determined and the resulting effective dose was calculated. The list of investigated imaging techniques consisted of cone beam computed tomography (kilo- and megavoltage), megavoltage fan beam computed tomography, kilo- and megavoltage planar imaging, planning computed tomography with and without gating methods and planar scout views. Results: A conventional 3D planning CT resulted in an effective dose additional to the treatment stray dose of less than 1 mSv outside of the treated volume, whereas a 4D planning CT resulted in a 10 times larger dose. For a daily setup of the patient with two planar kilovoltage images or with a fan beam CT at the TomoTherapy unit, an additional effective dose outside of the treated volume of less than 0.4 mSv and 1

  12. Qualidade fisiológica de sementes de arroz submetidas à radiação gama Physiological quality rice seed submitted to gamma radiation

    Directory of Open Access Journals (Sweden)

    Helen Lúcia da Cruz Miranda

    2009-08-01

    Full Text Available O objetivo deste trabalho foi avaliar os efeitos da radiação gama (Co60 na qualidade fisiológica de sementes de arroz. O estudo foi realizado em três ensaios. No primeiro ensaio, sementes de arroz foram irradiadas com doses de 0; 1; 2,5 e 5Gy e, para o segundo e o terceiro ensaio, as sementes foram submetidas a envelhecimento acelerado, antes da irradiação. No segundo ensaio, as sementes foram dividas em úmidas e secas após envelhecimento acelerado e, então, foram irradiadas nas doses 0; 1; 2,5 e 5Gy. No terceiro ensaio, as sementes foram secas após o envelhecimento acelerado e irradiadas com doses de 0, 10, 25 e 50Gy. Para avaliação dos efeitos fisiológicos da radiação gama, foram realizados teste de germinação - TG, índice de velocidade de germinação - IVG e crescimento de plantas (comprimento de parte aérea e sistema radicular e massa seca total, em todos os ensaios. Foram determinadas as atividades enzimáticas da fosfatase ácida e alfa amilase nas sementes secas, no segundo ensaio. Os resultados obtidos nos ensaios indicam que as doses de radiação gama estudadas não afetam a qualidade fisiológica das sementes de arroz.The objective of this research was to evaluate the effects of the gamma radiation (Co60 on the physiological quality of rice seeds. The research was carried out through three tests; in the first test rice seeds were irradiated at dosages of 0; 1; 2.5 and 5Gy, while for the second and third tests the seeds were subjected to accelerated aging before being irradiated. For the second test the seeds were divided into wet and dry and both groups subjected to accelerated aging previous to irradiation at dosages of 0; 1; 2.5 and 5Gy. For the third test the seeds were dried after being subjected to accelerated aging, and then irradiated at dosages of 0, 10, 25 and 50Gy. To assess the physiological effects of the gamma radiation, all seeds were tested for germination and their germination speed index recorded

  13. Entrance surface dose measurements in mammography using thermoluminescence technique

    International Nuclear Information System (INIS)

    Rivera, T.; Vega C, H.R.; Manzanares A, E; Azorin, J.; Gonzalez, P.R.

    2007-01-01

    Full text: Of the various techniques that can be used for personnel dosimetry, thermoluminescence dosimetry (TLD) has emerged as a superior technique due to its manifold advantages over other methods of dose estimation. Various phosphors have been therefore investigated regarding their suitability for dosimetry. In this paper, a dosimetry system based on thermally stimulated luminescence (TSL) from zirconium oxide phosphors embedded in polytetrafluorethylene (ZrO 2 +PTFE) was developed for entrance surface doses (ES) measurements in mammography. Small ZrO 2 pellets of 5 mm in diameter and 0.8 mm in thickness were used. The reproducibility of measurements and linearity of ZrO 2 were also studied. The results were compared with those obtained from LiF:Mg,Cu,P usually used for the determination of absorbed dose in mammography. Measurements both per unit air kerma and In vivo were performed using a mammography unit model DMR (General Electric). The results showed that ZrO 2 TLDs can be used for the same X-ray dosimetry applications as LiF:Mg,Cu,P, with each type having the disadvantage of a response dependent on energy, particularly at low energies. These results indicate a considerable potential for use in routine control and In vivo ES measurements in mammography. (Author)

  14. Re-distribution of brachytherapy dose using a differential dose prescription adapted to risk of local failure in low-risk prostate cancer patients

    DEFF Research Database (Denmark)

    Rylander, Susanne; Polders, Daniel; Steggerda, Marcel J

    2015-01-01

    BACKGROUND AND PURPOSE: We investigated the application of a differential target- and dose prescription concept for low-dose-rate prostate brachytherapy (LDR-BT), involving a re-distribution of dose according to risk of local failure and treatment-related morbidity. MATERIAL AND METHODS: Our study......- and dose prescription concept of prescribing a lower dose to the whole gland and an escalated dose to the GTV using LDR-BT seed planning was technically feasible and resulted in a significant dose-reduction to urethra and bladder neck....

  15. Assessment of micro-dose biplanar radiography in lower limb measurements in children

    International Nuclear Information System (INIS)

    Lerisson, Heloise; Amzallag-Bellenger, Elisa; Cebulski-Delebarre, Aurelie; Boutry, Nathalie; Nectoux, Eric; Herbaux, Bernard; Desmulliez, Geoffrey; Duhamel, Alain; Drumez, Elodie

    2018-01-01

    To evaluate in children microdose protocol compared with low dose for lower limb alignment (LLA) measurements on biplanar radiography. Children 6 years or older were included. Height, weight and hip width were measured prior to imaging. Hip width allowed classifying children into morphotype M1 (width <25 cm), M2 (25-35 cm) or M3 (>35 cm) corresponding to predefined acquisition parameters (kV, mA, tube speed). Micro- and low-dose protocols were used alternately, with simultaneous acquisition of frontal and lateral radiographs. LLA measurements were performed by two independent observers (n = 526). In 15 children per morphotype, a third observer performed measurements twice (n = 180). Intraclass correlation coefficients and the dose (delivered, absorbed) were calculated. 100 girls and 160 boys (mean age = 11.7 years) were investigated: 74 M1 (mean BMI, 15.7kg/m 2 ), 149 M2 (19.8 kg/m 2 ) and 40 M3 (30.2 kg/m 2 ). With microdose, inter- and intra-observer agreement was >0.90 for lengths whatever the morphotype, 0.75-0.90 (M1) and >0.90 (M2, M3) for valgus/varus and flexion/hyperextension deviations. Dose reduction reached a factor of 8.5 and 5.4 for the delivered and absorbed dose respectively. Microdose could be used for LLA measurements in children and permits a significant dose reduction. (orig.)

  16. RaD-X: Complementary measurements of dose rates at aviation altitudes

    Science.gov (United States)

    Meier, Matthias M.; Matthiä, Daniel; Forkert, Tomas; Wirtz, Michael; Scheibinger, Markus; Hübel, Robert; Mertens, Christopher J.

    2016-09-01

    The RaD-X stratospheric balloon flight organized by the National Aeronautics and Space Administration was launched from Fort Sumner on 25 September 2015 and carried several instruments to measure the radiation field in the upper atmosphere at the average vertical cutoff rigidity Rc of 4.1 GV. The German Aerospace Center (Deutsches Zentrum für Luft- und Raumfahrt) in cooperation with Lufthansa German Airlines supported this campaign with an independent measuring flight at the altitudes of civil aviation on a round trip from Germany to Japan. The goal was to measure dose rates under similar space weather conditions over an area on the Northern Hemisphere opposite to the RaD-X flight. Dose rates were measured in the target areas, i.e., around vertical cutoff rigidity Rc of 4.1 GV, at two flight altitudes for about 1 h at each position with acceptable counting statistics. The analysis of the space weather situation during the flights shows that measuring data were acquired under stable and moderate space weather conditions with a virtually undisturbed magnetosphere. The measured rates of absorbed dose in silicon and ambient dose equivalent complement the data recorded during the balloon flight. The combined measurements provide a set of experimental data suitable for validating and improving numerical models for the calculation of radiation exposure at aviation altitudes.

  17. Effectiveness of rapid neutrons on small hoarse bean seed

    International Nuclear Information System (INIS)

    Szlek, S.; Janiszewski, T.

    1986-01-01

    The small hoarse bean seeds were irradiated. The radiation doses 100-300 rads were used. The obtained mutants were applied in the breeding. The use of fast neutrons was successful and shortened the breeding cycle. (A.S.)

  18. Photon and neutron doses of the personnel using moisture and density measurement devices

    Energy Technology Data Exchange (ETDEWEB)

    Carinou, E.; Papadomarkaki, E.; Tritakis, P.; Hourdakis, C.I.; Kamenopoulou, V. [Greek Atomic Energy Commission, Agia Paraskevi, Attiki, 60092 (Greece)

    2006-07-01

    The objective of this study is to present the evolution of the photon doses received by the workers who use mobile devices for measuring the moisture and the density in various materials and to estimate the neutron doses. The workers employed in more than 30 construction companies in Greece were 76 in 2004. The devices used for that purpose incorporate a {sup 137}Cs source for density measurements and an {sup 241}Am-Be source for moisture measurements of soil, asphalt or concrete. Photon and neutron measurements were performed occasionally during the on site inspections. The results of the measurements showed that the photon and neutron dose rates were not negligible. The workers were monitored for photon radiation using film badges (Kodak Type 2, Holder NRPB type) till the year 2000 and then TLD badges issued by the Greek Atomic Energy Commission (GAEC), on a monthly basis. Since the neutron dose rates measured by a rem-meter were not so high, no neutron dosemeters were issued for them. Their personal dose equivalent data for photons are kept in the National Dose Registry Information System (N.D.R.I.S.) in G.A.E.C. and were used for statistical analysis for the period from 1997 till 2004. As far as the neutrons are concerned, a Monte Carlo code was used to simulate the measuring devices and the working positions in order to calculate the neutron individual doses. (authors)

  19. Photon and neutron doses of the personnel using moisture and density measurement devices

    International Nuclear Information System (INIS)

    Carinou, E.; Papadomarkaki, E.; Tritakis, P.; Hourdakis, C.I.; Kamenopoulou, V.

    2006-01-01

    The objective of this study is to present the evolution of the photon doses received by the workers who use mobile devices for measuring the moisture and the density in various materials and to estimate the neutron doses. The workers employed in more than 30 construction companies in Greece were 76 in 2004. The devices used for that purpose incorporate a 137 Cs source for density measurements and an 241 Am-Be source for moisture measurements of soil, asphalt or concrete. Photon and neutron measurements were performed occasionally during the on site inspections. The results of the measurements showed that the photon and neutron dose rates were not negligible. The workers were monitored for photon radiation using film badges (Kodak Type 2, Holder NRPB type) till the year 2000 and then TLD badges issued by the Greek Atomic Energy Commission (GAEC), on a monthly basis. Since the neutron dose rates measured by a rem-meter were not so high, no neutron dosemeters were issued for them. Their personal dose equivalent data for photons are kept in the National Dose Registry Information System (N.D.R.I.S.) in G.A.E.C. and were used for statistical analysis for the period from 1997 till 2004. As far as the neutrons are concerned, a Monte Carlo code was used to simulate the measuring devices and the working positions in order to calculate the neutron individual doses. (authors)

  20. Measurement of MV CT dose index for Hi-ART helical tomotherapy unit

    International Nuclear Information System (INIS)

    Wang Yunlai; Liao Xiongfei

    2010-01-01

    Objective: To evaluate the patient dose from Hi-ART MV helical CT imaging in image-guided radiotherapy. Methods: Weighted CT dose index (CTDI W ) was measured with PTW TM30009 CT ion chamber in head and body phantoms, respectively,for slice thicknesses of 2, 4, 6 mm with scanned range of 5 cm and 15 cm. Dose length products (DLP) were subsequently calculated. The CTDI W and DLP were compared with XVI kV CBCT and ACQSim simulator CT for routine clinical protocols. Results: An inverse relationship between CTDI and the slice thickness was found. The dose distribution was inhomogeneous owing to the attenuation of the couch. CTDI and DLP had close relationship with the slice thickness and the scanned range. Patient dose from MVCT was lower than XVI CBCT for head, but larger for body scan. Conclusions: CTDI W can be used to assess the patient dose in MV helical CT due to its simplicity for measurement and reproducibility. Regular measurement should be performed in QA and QC program. Appropriate slice thickness and scan range should be chosen to reduce the patient dose. (authors)