WorldWideScience

Sample records for seed 125i implantation

  1. First symposium seed implant 125I and high rate of prostate

    International Nuclear Information System (INIS)

    2012-01-01

    The First symposium seed implant 125 I and high rate of prostate, was organized by the Marie Curie Foundation, between the 12 to april 2012, in the Cordoba city of Argentina. In this event were presented several documents in different topics: patients selection for impacts of 125 I seeds; high doses radiation in radiotherapy; brachytherapy for prostate cancer; prostate implant technique with 125 I seeds; implant dosimetric aspects; radioprotection of 125 I seeds.

  2. Efficacies of 125I seed implantation in advanced stage central lung cancer via fibrobronchoscope

    International Nuclear Information System (INIS)

    Liu Jianguo; An Liqing; Cheng Jinguang; Zhang Yufen; Guo Xiaokui

    2009-01-01

    Objective: To explore the temporal curative effect of 125 I seed implantation in advanced stage central type lung cancer. Methods: 125 I seed was implanted in 56 patients confirmed advanced stage central type lung cancer via fibrobronchoscope and all cases were fellow up in certain duration to explore their efficacies and the adverse reaction. Results: Total efficient rate was 76.78% in 56 patients. Lung reexpanded rate was 90.90%. Conclusion: The therapy of 125 I seed implantation in advanced stage central type lung cancer is safe and available. (authors)

  3. Ten cases of metastatic cervical cancer with the treatment of permanent 125I seeds interstitial implants

    International Nuclear Information System (INIS)

    Zhang Hongwei; Li Naibin; Li Qingxin; Liu Huiping; Meng Hui; Chao Dong

    2011-01-01

    Objective: To investigate the clinical effect of permanent 125 I seeds interstitial implants for metastatic cervical cancer. Methods: Under the guidance of the B-sonography, 125 I seeds were implanted into the eleven cervical lymph nodes of ten patients who had been given tumor resection. The pain relief and tumor size were observed in regular follow-up after one-month treatment. Results: All the patients were followed up for 6-14 months,and the postoperative recovery was good with no complication. One month after the implantation, the pain symptom was alleviated entirely in two nodes and partly in nine nodes. The tumor size shrank in ten nodes while there was no change in one node after one month. Conclusion: Permanent 125 I seeds interstitial implants for metastatic cervical cancer is a safe, minimally invasive and effective treatment. (authors)

  4. Clinical efficacy of CT-guided 125I seed implantation therapy for advanced pancreatic cancer

    International Nuclear Information System (INIS)

    Wang Zhongmin; Lu Jian; Gong Ju; Zheng Yunfeng; Zhang Liyun; Huang Gang; Chen Kemin

    2009-01-01

    Objective: To discuss the clinical efficacy of CT-guided radioactive 125 I seed implantation treatment for unresectable pancreatic cancer. Methods: Forty patients with inoperable pancreatic cancer were enrolled in this study, including 25 males and 15 females with an median age of 69 years (38-89 years). Treatment planning system (TPS) was used to reconstruct 3-dimensional images of pancreatic tumor and to define the quantity and distribution of 125 I seeds. The radioactivity of 125 I seeds was 0.5 - 0.8 mCi / seed. The seeds were implanted into pancreatic tumor under CT guidance at intervals of 1 cm and were kept away from vessels, pancreatic duct and other adjacent important organs. The tumor matched peripheral dose (MPD) was 60-140 Gy. The median amount of implanted 125 I seeds was 36 (18-68) in number. CT scan was performed immediately after the procedure to check the quality of the seeds. In addition, 10 patients received concurrent chemotherapy with arterial infusion of gemcitabin and 5-fluororacil (5-Fu) for 3 to 4 therapeutic courses. Results: The median diameter of the tumors was 4.9 cm. The follow-up period was 2 to 28 months. After the treatment the refractory pain was significantly relieved (P 125 I seed implantation is a safe, effective and minimally-invasive brachytherapy for unresectable pancreatic cancer with reliable short-term efficacy. It has an excellent anti-pain effect. The curative results can be further improved when chemotherapy is employed together. However, its long-term efficacy needs to be observed. (authors)

  5. Investigation on curative efficacy for malignant tumor by implantation '125I permanent brachytherapy seeds

    International Nuclear Information System (INIS)

    Hu Shu; Gao Zhou; Jia Shaowei; Cheng Xianyi; Chen Junhui; Yin Weihua; Sun Desheng

    2011-01-01

    Twenty inpatients suffered from malignant tumors with twenty-four lesions were treated with 125 I permanent brachytherapy seed in Peking University Shenzhen Hospital, and the feasibility, curative effect and adverse effect of the treatment were observed. Before 125 I seeds implantation, the three-dimensional treatment planning was preconcerted. There were two methods to implant 125 I seeds. One was to insert the seeds in the location of residual focus and metastatic lesions of the tumors directly in ordinary operations or through laparoscopy under general anesthesia. The other w as to implant the seeds into the tumors through percutaneous needles by the guidance of CT scanning or color doppler ultrasonography under local anesthesia. The implantations for all of the 20 patients (24 lesions) were performed successfully. During and one week after the implantation, the distributions of the planted seeds were approximately the same as the scheduled three-dimensional treatment planning, and no seed migration was found. Adverse reactions during and after the operation were slight and recovered after correlative treatments. Clinical symptoms were palliated and ser um tumor marker decreased to a different extent among most patients. The complete remission (CR) rate is 20.00% (4/20 patients ), the partial emission (PR) rate is 35.00% (7/20 patients), the stable disease (SD) rate is 30.00% (6/20 patients), the progressive disease (PD) rate is 15.00% (3/20 patients), and the overall response rate (CR + PR) is 53.33% (8 patients). 125 I seeds implantation for targeted therapy is convenient, safe and effective on malignant tumor, and is well worth advanced application. (authors)

  6. CT-guided interstitial 125I seed implantation for intractable pelvic recurrence of rectal carcinomas

    International Nuclear Information System (INIS)

    Lin Zhenwen; Chu Hong; Kong Jian; Dou Yongchong

    2011-01-01

    Objective: To evaluate the therapeutic effect and safety of CT-guided interstitial 125 I seed implantation in treating intractable pelvic recurrence of rectal carcinomas. Methods: During the period from April 2010 to September 2010 CT-guided interstitial 125 I seed implantation was carried out in 11 patients with pelvic recurrence of rectal carcinoma which developed after the patients had received comprehensive treatments such as surgical resection, chemotherapy and/or radiotherapy. The clinical data were retrospectively analyzed. The clinical symptoms, the tumor size and the quality of life (QOL) before the treatment and at two and six months after the treatment were recorded, and the complications were observed. The results were compared. All the patients were followed up for six months. Results: At two and six months after the treatment, the improvement rate of the clinical symptoms was 100.0% (11/11) and 90.9% (10/11) respectively, while the effective reduction of the tumor size was 90.9% (10/11) and 81.8% (9/11) respectively. At two and six months after the treatment the QOL score was (56.0±3.66) and (54.4±5.41) respectively, both of which were higher than the QOL score determined before the treatment (42.5±6.93), the difference between them was statistically significant (P 125 I seed implantation has satisfactory short-term effect. This treatment is also quite safe and effective for patients who are unbearable to external radiation therapy due to the tissue dose restriction. (authors)

  7. The clinical application of TACE together with RFA and 125I seed implantation in treating hepatocellular carcinoma

    International Nuclear Information System (INIS)

    Xie Xiaoxi; Lu Yinxiang; Zhang Hongxin; Zhang Shengchu; Zhou Jianwei; Zhang Guodong; Wang Xiaowei; Yang Liping

    2011-01-01

    Objective: to assess the clinical value of the combined treatment of transcatheter arterial chemoembolization (TACE), CT-guided radiofrequency ablation (RFA) and radioactive 125 I seed implantation for hepatocellular carcinoma (HCC). Methods: During the period from March 2008 to Dec. 2010, 15 patients with HCC were admitted to the hospital. A total of 25 hepatic lesions were detected with the size of 1-8 cm. TACE was carried out first, which was followed by CT-guided RFA and radioactive 125 I seed implantation. With the help of treat plan system (TPS), the radioactive 125 I seed implantation was conducted to make additional management for the same lesion when RFA was finished, or the radioactive 125 I seeds were directly implanted into the areas where RFA could not reach. The radioactive dose was 60-100 Gy. All the patients were followed up and were kept under observation for the signs of related complications. The therapeutic results were evaluated. Results: The combined treatment was successfully accomplished in all patients. All patients were followed up for 3-28 months (mean of 10.6 months). The complete necrosis rate of the tumor was 96%. No serious complications occurred except the immigration of 125 I seeds in 1 case. Conclusion: The combined treatment of TACE and CT-guided RFA together with 125 I seed implantation is a safe, reliable and effective therapy for HCC with excellent short-term result. (authors)

  8. Radiation safety and protection of close contacts from radiators after implantation of radioactive 125I seeds

    International Nuclear Information System (INIS)

    Sui Aixia; Li Jianmin; Tang Fulong; Zhang Hongtao; Ren Ju'na; Pang Linbin; Xia Haishui; Gao Zhen; Wu Lili; Wang Juan

    2012-01-01

    Objective: To study the effective dose and precaution time of the irradiation of the close contact from the radiators who underwent implantation of radioactive 125 I seeds so as to guide scientifically people how to avoid radiation damage. Methods: Twenty patients with different types of cancer underwent implantation of radioactive 125 I seeds with the median value of implantation depth of 2.16 cm. Within 24 h after the operations the dose rates 30 cm and 100 cm from the skin were measured with pocket-size radiometer so as to imitate the situations of the close contacts. The effective doses and precaution times of different persons were calculated according to relevant formula. Results: The dose rate a person received at the same time points (1, 54, 78, and 109 d, respectively) decreased along with the increase of the distance from the skin (t=5.962, 5.961, 5.961, 5.962, P<0.05), and the dose rate a person received at the same distance from the skin decreased along with the extension of time (30 cm: t=6.236, 6.236, 6.235, P<0.05; 100 cm: t=7.310, 7.315, 7.314, P<0.05). At different time points, the dose rates at 30 cm distance point were all significant higher than those at the 100 cm point (P <0.05). The adult living together, minors and pregnant women sharing the room, colleagues,adults who slept together with the patients began to reach the 50% dose constraint values 0, 54, 78 and 109 days after the operation. Conclusions: After their precaution time, it's safe to contact with the patients for the groups; otherwise, it's necessary to take some protect works within the precaution time. (authors)

  9. Clinical analysis of 125I seed implants in worst-casts of the malignant tumors after radiography and chemotherapy

    International Nuclear Information System (INIS)

    Chen Zhijun; Tu Xinhua; Zhou Aiqing; Wang Xueqin

    2006-01-01

    Objective: To investigate the curative effect and side reaction after 125 I seed implanted among tissue were treated the malignant neoplasm by radiography and chemotherapy. Methods: Retrospective analysis the cancerous sufferer after the failure of radiography and chemotherapy, percutaneous puncture or intraoperative under gaze forward 125 I seed were implanted the bed of the tumour forever. Follow-up blood routine examination, symptom, sign, using USG or CT observe the change of the tumour and the distribution of the particles etc. Results: In 3 cases, treat 2 cases, tumour reduced obviously, symptoms improved obviously, the face of the ulcer cured, the particles did not shift, hemogram did not decline obviously. Conclusion: 125 I seed among the tissue implanted forever for the unsuccessful case after radiography and chemotherapy supply a new therapeutic methods. In the neat future curative effect is exactly, toxic reaction is small, which can remedy the deficiency of the treatment for radiography and chemotherapy. (authors)

  10. Nursing care for patients with local recurrent rectal cancer after CT-guided 125I seed implantation therapy

    International Nuclear Information System (INIS)

    Yuan Li; Wei Fan; Ren Caifeng; Tu Mingmei; Qian Guixiang

    2010-01-01

    Objective: To discuss the nursing care strategy for patients with local recurrent rectal cancer who has been treated with CT-guided 125 I seed implantation therapy. Methods: Twenty patients with local recurrent rectal cancer received a series of nursing interventions, including comfort care and pain care. The clinical results were observed and analyzed. Results: The therapy was smoothly accomplished in all patients. The pain was remarkably relived and the anxiety was alleviated. No displacement of implanted 125 I seed occurred. Conclusion: For patients with local recurrent rectal cancer occurred after CT-guided 125 I seed implantation therapy, careful nursing can effectively relieve the pain and anxiety feeling,and the living quality can also be markedly improved. (authors)

  11. Radiation protective nursing intervene of 125I seed implantation in non-small cell lung carcinoma guided by CT

    International Nuclear Information System (INIS)

    Fu Li; Zhang Zuncheng; Yu Zhaochen; Zheng Guangjun; Tian Meirong

    2009-01-01

    Objective: To research radiation protective nursing intervene and important notice of 125 I seeds minimally invasive implantation in non-small cell lung carcinoma (NSCLC) by CT. Methods: Under the system of therapy planning system (TPS) and posologic validation, 125 I seeds were implanted in 89 cases of NSCLC patients. The consistent radiation protective nursing intervene was used in perioperative period management. The operative successful rate, therapeutic effect and complication rate, therapeutic effect and complication rate was observed. Results: The scientific radiation protective nursing intervene can ensure that the radioactive dose distribution of 125 I seed implantation brachytherapy is consistent with the principles of effective and minimally invasive. The operative successful rate was 100%. The local control rate and 1 year survival rate respectively was 97.4% and 92.2%. But the early and later incidence rate of radioactive damaging effect was 14.6% and 1.1% respectively. Leakage of radioactive contamination has not occurred. Conclusion: The consistent TPS and posologic validation 125 I seeds implantation integrated scientific radiation protective nursing intervene. It is very important to improve the therapeutic effect of NSCLC and reduce the incidence of complications. (authors)

  12. Development of measurement method using TLD for workers occupation personally exposed to 125I seed source in the implant

    International Nuclear Information System (INIS)

    Luo Suming; He Zhijian; Yuan Jilong; Yue Baorong; Wei Kedao

    2011-01-01

    Objective: To explore the method for measuring and calculating both absorbed dose and effective dose received in organ and tissues of occupational workers by using TLDs for the implantation of 125 I seed sources. Methods The experiments with 60 Co γ-rays were carried out for the stability. A group of TLD chips was exposed to 125 I seed sources to establish standard dose curve for air kerma. During the 125 I seed implantation, the TLD chips were pasted to 13 locations like thyroid inside and outside the lead aprons worn by occupational workers to measure average absorbed dose and calculate the absorbed doses and effective to organs and tissues. Results: For 3 cases of prostate cancers with implantation of 125 I seeds, the worker's organs and tissues received the absorbed dose 0.02 -3.80 μ Gy and effective dose 0.06- 1.81 μSv outside lead aprons and the highest absorbed dose 2.35 μ Gy and effective 0.02 μSv inside lead aprons, respectively, with more than 65.9% of rays shielded. For 3 cases of brain cancers with implantation of 125 I seeds, the workers received the absorbed dose 0.23 - 11.31 μGy and effective dose 0.88-4.07 μSv outside lead aprons and the highest absorbed dose 2.22 μ Gy and effective dose 0.09 μSv inside lead aprons, respectively, with more than 54.5% of rays shielded. For 3 cases of lung cancers with implantation of 125 I seeds, the workers received the absorbed dose 0.03 - 14.78 μGy and effective dose 0.35 -7.59 μSv outside lead aprons and the highest absorbed dose 4.09 μGy and effective 0.22 μSv inside lead aprons, respectively, with more than 58.4% of rays shielded. For 2 cases of mediastinum cancers with implantation of 125 Iseeds, the workers received the absorbed dose 0.06 - 74.91 μGy and effective dose 0.83-17.96 μSv outside lead aprons and the highest absorbed dose 10.29 μGy and effective 0.5 μSv inside lead aprons, respectively, with more than 85% of rays shielded. For one case of ovary cancer with implantation of 125

  13. Dosimetry study of three-dimensional print template-guided precision 125I seed implantation

    Directory of Open Access Journals (Sweden)

    Zhang Hongtao

    2016-01-01

    Conclusions: The postplan and preplan dose parameters of 3D print template-guided seed implantation were nearly consistent. The dose parameters of template group superior to the traditional group. The seeds can be implanted accurately with 3D print template.

  14. Three-dimensional verification of 125I seed stability after permanent implantation in the parotid gland and periparotid region

    International Nuclear Information System (INIS)

    Fan, Yi; Huang, Ming-Wei; Zheng, Lei; Zhao, Yi-Jiao; Zhang, Jian-Guo

    2015-01-01

    To evaluate seed stability after permanent implantation in the parotid gland and periparotid region via a three-dimensional reconstruction of CT data. Fifteen patients treated from June 2008 to June 2012 at Peking University School and Hospital of Stomatology for parotid gland tumors with postoperative adjunctive 125 I interstitial brachytherapy were retrospectively reviewed in this study. Serial CT data were obtained during follow-up. Mimics and Geomagic Studio software were used for seed reconstruction and stability analysis, respectively. Seed loss and/or migration outside of the treated area were absent in all patients during follow-up (23–71 months). Total seed cluster volume was maximized on day 1 post-implantation due to edema and decreased significantly by an average of 13.5 % (SD = 9.80 %; 95 % CI, 6.82–17.68 %) during the first two months and an average of 4.5 % (SD = 3.60 %; 95 % CI, 2.29–6.29 %) during the next four months. Volume stabilized over the subsequent six months. 125 I seed number and location were stable with a general volumetric shrinkage tendency in the parotid gland and periparotid region. Three-dimensional seed reconstruction of CT images is feasible for visualization and verification of implanted seeds in parotid brachytherapy

  15. The effect of interstitial 125I seeds implantation on intestinal wall: a pathological observation in experimental dogs

    International Nuclear Information System (INIS)

    Ning Houfa; Zhang Fenglian; Shen An; Cao Guiwen; Cui Xinjiang

    2010-01-01

    Objective: To observe the radiation injury of the bowel wall due to the implantation of interstitial 125 I seeds in experimental dogs. Methods: A total of 12 healthy male dogs were randomly and equally divided into 3 experimental groups and 1 control group, with 3 dogs in each group.In the experimental groups, two 125 I seeds with the active radiation dose of 0.8mCi were symmetrically implanted under the serous membrane of the dog's small intestinal wall. The dogs were fed for 14 days (group A), for one month (group B) and for two months (group C) respectively when the animals were scheduled to be sacrificed. The dogs' general condition was observed till they were sacrificed. The seed-implanting intestinal segments were then removed and dyed with HE staining method for electronic microscopic exam. The histopathologic findings were recorded and the results were compared between four groups. Results: No obvious histopathological changes were found in the dog's bowel wall 14 days after the implantation. One month after the procedure cellular injury was observed under electronic microscope, and two months after the operation partial fibrosis of the intestinal wall appeared but no ulceration or perforation occurred. Conclusion: The implantation of 125 I seeds can cause reversible cellular injuries of the intestinal wall in experimental dogs, the degree of the damage reaches its peak at one month after the implant when the partial fibrosis of bowel wall becomes evident. However, the seeds do not cause any serious complications, such as ulceration or perforation. (authors)

  16. {sup 125}I seed implant brachytherapy for the treatment of parotid gland cancers in children and adolescents

    Energy Technology Data Exchange (ETDEWEB)

    Zheng, L.; Zhang, J.; Song, T.; Zhang, J.; Yu, G.; Zhang, Y. [Peking University School and Hospital of Stomatology, Beijing (China). Dept. of Oral and Maxillofacial Surgery

    2013-05-15

    Background and purpose: There is a lack of optimal treatment strategies for managing salivary gland cancers in children and adolescents. This study is aimed at assessing the effect of {sup 125}I seed implantation for the treatment of parotid cancers in children and adolescents. Patients and methods: A total of 12 patients younger than 16 years with parotid gland malignant tumors underwent {sup 125}I seed implant brachytherapy between October 2003 and November 2008. All patients were assessed after treatment and at the local tumor control appointments. Facial nerve function, maxillofacial development, and radioactive side-effects were assessed. Results: The follow-up period ranged from 41-104 months. One patient with T4b died of pulmonary metastasis. The other patients were alive during the follow-up period. There were no serious radiation-related complications. The treatment did not affect facial nerve function and dentofacial growth in any of the children. Conclusion: For parotid gland cancers in children, {sup 125}I seed implant brachytherapy may be an acceptable treatment without serious complications and with satisfactory short-term effects. (orig.)

  17. CT-guided radioactive 125I-seed implantation for the treatment of pancreatic carcinoma: a clinical observation of 19 cases

    International Nuclear Information System (INIS)

    Lu Jian; Zheng Yunfeng; Zhang Huan; Wang Zhongmin; Chen Kemin

    2010-01-01

    Objective: To explore the dynamic changes of serum tumor markers after CT-guided radioactive 125 I-seed implantation treatment in patients with pancreatic carcinoma and to assess the therapeutic effectiveness of 125 I-seed implantation. Methods: CT-guided radioactive 125 I-seed implantation was performed in 19 patients with unresectable advanced pancreatic cancer. Treatment planning system was used to reconstruct 3-dimentional images of the tumor, and the quantity and distribution of 125 I-seeds to be implanted were thus determined. Under CT guidance 125 I-seeds were embedded into pancreatic cancer. Before and after the 125 I-seed implantation the levels of serum tumor markers, including CEA, CA19-9 and CA50, were determined by using radioimmunoassay method. The clinical effects were observed and the therapeutic results were statistically analyzed. Results: The pain stared to be relieved 2 to 5 days after implantation. The total effective rate (CR + PR) at one and three months after treatment was 68.42% (13 /19) and 63.16% (12 /19) respectively. One month after 125 I-seed implantation, the levels of serum CEA, CA19-9 and CA50 were significantly different to that determined before implantation in all cases (P 125 I-seed implantation is a safe and effective interventional treatment for advanced pancreatic cancer with reliable short-term result and remarkable pain-relieving effect. Moreover, this therapy can significantly lower the levels of many serum tumor markers, which play some suggestive roles in evaluating the clinical curativeness. (authors)

  18. Optimum timing for image-based dose evaluation of 125I and 103Pd prostate seed implants

    International Nuclear Information System (INIS)

    Yue Ning; Chen Zhe; Peschel, Richard; Dicker, Adam P.; Waterman, Frank M.; Nath, Ravinder

    1999-01-01

    timing for conventional postimplant dose evaluation was identified as the time at which a minimum difference between the conventional DVH and the dynamic model DVH was achieved. The analysis was done on 29 prostate seed implant patients for both 125 I and 103 Pd. The edema magnitude was assumed to be 30%, 40%, 50%, 75%, and 100% of original prostate volume, and the half-life of edema was assumed to be 4, 7, 10, 15, 20, and 25 days. In this study, the original volume of prostate varied from 17 cm 3 to 91 cm 3 , and number of seeds in the implants varied from 57 to 119. Results: The optimum timing was mainly dependent on the half-lives of edema and radionuclides, and varied slightly with edema magnitude, prostate volume, and number of seeds. It can be expressed as a function of edema half-life in the form of C 0 + C 1 exp(-C 2 T e ). However, if the dose evaluation was performed based on the image scans taken too early or too late, the error became larger, as the edema magnitude was larger. By averaging all 29 patients and various edemas, it was found that for 125 I seed implants, if the postimplant dose evaluation is performed based on image scans taken between 5 and 9 weeks, the average error will be less than 5%, with a maximum possible error less than 10% in 80% coverage dose; for 103 Pd seed implants, if the postimplant dose evaluation is performed based on image scans taken between 2 and 4 weeks, the average error will be less than 5%, with a maximum error less than 15% in 80% coverage dose. Because of edema, a conventional preimplant plan also overestimates dose coverage of prostate. On the average, a standard preimplant planning overestimates dose coverage by about 6% for 125 I implants and 14% for 103 Pd implants in our study. Conclusion: Based on the dynamic model, the optimum timing of image scans for postimplant dose evaluation of prostate seed implantation is 7 weeks postimplantation for 125 I implants and about 3 weeks for 103 Pd implants. The time-window for

  19. Clinical Study on Using 125I Seeds Articles Combined with Biliary Stent Implantation in the Treatment of Malignant Obstructive Jaundice.

    Science.gov (United States)

    Wang, Tao; Liu, Sheng; Zheng, Yan-Bo; Song, Xue-Peng; Sun, Bo-Lin; Jiang, Wen-Jin; Wang, Li-Gang

    2017-08-01

    Aim: To study the feasibility and curative effect of 125 I seeds articles combined with biliary stent implantation in the treatment of malignant obstructive jaundice. Patients and Methods: Fifty patients with malignant obstructive jaundice were included. Twenty-four were treated by biliary stent implantation combined with intraluminal brachytherapy by 125 I seeds articles as the experimental group, while the remaining 26 were treated by biliary stent implantation only as the control group. The goal of this study was to evaluate total bilirubin, direct bilirubin and tumor markers (cancer antigen (CA)-199, CA-242 and carcinoembryonic antigen (CEA)), as well as biliary stent patency status and survival time before and after surgery. Results: Jaundice improved greatly in both groups. The decreases of CA-199 and CA-242 had statistical significance (p=0.003 and p=0.004) in the experimental group. The ratio of biliary stent patency was 83.3% (20/24) in the experimental group and 57.7% (15/26) in the control group (p=0.048). The biliary stent patency time in the experimental group was 1~15.5 (mean=9.84) months. The biliary stent patency time in the control group was 0.8~9 (mean=5.57) months, which was statistically significant (p=0.018). The median survival time was 10.2 months in the experimental group, while 5.4 months in control group (pjaundice possibly by inhibiting the proliferation of vascular endothelial cells and the growth of tumor. Copyright© 2017, International Institute of Anticancer Research (Dr. George J. Delinasios), All rights reserved.

  20. Effect of Foley catheters on seed positions and urethral dose in 125I and 103Pd prostate implants

    International Nuclear Information System (INIS)

    Brezovich, Ivan A.; Pareek, Prem N.; Duan, Jun; Fiveash, John

    2001-01-01

    Purpose: To estimate the perturbation of seed position and urethral dose, subsequent to withdrawal of urethral catheters. Methods and Materials: A mathematical model based on the volume incompressibility of tissues was used to compute seed positions and doses following removal of the Foley. The model assumed that the central axis of the urethra remains stationary, and that prostate tissue and seeds move radially toward the center of the urethra to fill the void left by the catheter. Seed motion has also been measured using transrectal ultrasound. Results: Based on the computations, seeds located originally close to the urethra travel relatively large distances toward the urethra upon Foley removal, whereas seeds located further away move substantially less. This seed motion leads to higher urethral doses than shown in a standard treatment plan. Dose enhancements increase with catheter size, decrease with increasing prostate volume, are more pronounced for 103 Pd than for 125 I, and range between 3.5% and 32.4%. Postimplant dosimetry is equally affected if images are taken with urethral catheters in place, showing lower urethral doses than actually delivered. Preliminary ultrasound based measurements of seed motion agree with the theory. Conclusion: During the implantation procedure, 12 fr or smaller urethral catheters are preferable to larger diameter catheters if urine drainage is sufficient. Treatment planners should avoid planning seeds at 5 mm or closer from the urethra. Special caution is indicated in prostates having about 20 cm 3 or smaller volumes, and when 103 Pd is used. Postimplant dosimetry is susceptible to the same errors

  1. Study of percutaneous 125I seeds implantation guided by CT in elderly patients of stage I peripheral non-small cell lung cancer

    International Nuclear Information System (INIS)

    Ke Mingyao; Yong Yazhi; Luo Bingqing; Wu Xuemei; Chen Lingling; Xie Hongqi

    2011-01-01

    Objective: To evaluate the efficacy, feasibility and safety of CT guided percutaneous 125 I seeds implantation in elderly patients of stage I peripheral non-small cell lung cancer (NSCLC). Methods: Clinical data of 16 elderly peripheral stage I NSCLC patients (10 squamous carcinoma and 6 adenocarcinoma; 13 stage I A and 3 stage I B ) who received radioactive 125 I seeds implantation because of refusal or being unsuited to operation or external radiotherapy were retrospectively analyzed. Prescribed dose was 140 - 160 Gy. Under CT guidance, 125 I seeds were implanted percutaneously into tumors for interstitial radiotherapy according to treatment plan system. Results: Mean number of 125 I seeds each patient received was 21.1. 12 complete response (CR) and 4 partial response (PR) were achieved. Total response rate (CR + PR) was 100%. 100% patients completed 10 to 56 months of follow-up, 15, 13, 8 and 6 patients completed 1-, 2-, 3-and 4-years' follow-up, respectively. The median local progression free time was 14 months. The 1-, 2-, 3-and 4-year overall survival rate were 60%, 54%, 50% and 33%, respectively (median : 14 months). 7 cases died of non-tumor disease and 5 died of metastasis. No severe complications were observed. Conclusions: CT guided 125 I seeds implantation is a safe, reliable and effective radical treatment method for elderly stage I peripheral NSCLC patients, who refuse to or are unsuitable to operation or external radiotherapy. (authors)

  2. Effect of implanted radioactive 125I seeds on normal tissue structures of bronchus, esophagus, pulmonary artery, pulmonary vein and alveolus in dogs

    International Nuclear Information System (INIS)

    Qi Liangchen; Han Zhenguo; Yang Bin; Heersitai

    2008-01-01

    Objective: To investigate the effect of implanted radioactive 125 I seeds on normal tissue structures of bronchus, esophagus, pulmonary artery, pulmonary vein and alveolus in dogs. Methods: Nine healthy male dogs weighing 17-21 kg were randomly divided into three groups: 30 d, 60 d experimental groups and control group. Radioactive 125 I seeds (3.7 x 10 7 Bg, 1.0 mCi) were implanted into the sides of bronchus, esophagus, pulmonary artery, pulmonary vein respectively, the samples of bronchus, esophagus, pulmonary artery, pulmonary vein were taken 30 and 60 d after transplantation, HE staining was used to observe the pathologic changes of the tissues under light microscope. Results: The damages of normal bronchus, esophagus, pulmonary artery, pulmonary vein and alveolus after radioactive 125 I seeds implantation in 30 d group were weaker than those in control group and 60 d group, there were no complications such as perforation, hemorrhage, necrosis, etc. Histopathological score indicated that the scores of bronchus, esophagus and alveolar in 30 d group and 60 d group were higher than those in control group (P 0.05); there was no significant difference in histopathological score of pulmonary vein among all groups (P>0.05). Conclusion: The implanted radioactive 125 I seeds can damage all kinds of tissues at different degrees, but this kind of damage is reversible, the dog may repair the damage through its own repair ability, its clinical application is safe. (authors)

  3. CT-guided percutaneous vertebroplasty combined with 125I-seed implantation for metastatic vertebral carcinoma involving the spinal canal: analysis of 23 cases

    International Nuclear Information System (INIS)

    Xie Xiaoxi; Lu Yinxiang; Ji Yong; Wang Xiaowei; Zhang Guodong

    2014-01-01

    Objective: To evaluate the safety and efficacy of CT-guided percutaneous vertebroplasty (PVP) combined with 125 I-seed implantation for the treatment of metastatic vertebral carcinoma involving the spinal canal. Methods: A total of 28 involved vertebrae were detected in 23 patients with metastatic vertebral carcinoma. Each patient had 1-2 diseased vertebrae. The lesions included cervical vertebra (n=4), thoracic vertebra (n=13) and lumbar vertebra (n=11). Destroyed posterior vertebral wall was seen in all involved vertebrae. Thirteen vertebrae found in 12 patients showed involvement of the epidural space. According to treatment planning system (TPS) CT-guided implantation of 125 I seeds was carried out first for cervical lesions, which was followed by PVP. For the thoracic and lumbar lesions, unilateral or bilateral puncturing with several particle needles was employed to implant the 125 I seeds, then, PVP with bone cement injection was performed. The complications and the clinical efficacy were analyzed. Results: Successful operation was obtained in all patients. The number of implanted 125 I seeds ranged from 4 to 30 per vertebra, and the volume of injected bone cement was 1-6 ml per vertebra. After the operation the pain relief rate was 86.9% (n=20). The incidence of bone cement leakage was 17.8% (5/28). One patient had radicular pain caused by neuropore leakage, which was relieved after medication. No serious complications, such as spinal cord injury or radiation myelitis, occurred. Conclusion: CT-guided PVP combined with 125 I-seed implantation is effective and safe for the treatment of metastatic vertebral carcinoma involving the spinal canal. This therapy can effectively relieve the pain and control the deterioration of tumor, besides, the incidence of bone cement leakage is very low. (authors)

  4. Dynamic observation on changes of serum tumor markers levels after implantation of 125I radioactive seeds as treatment for several malignancies

    International Nuclear Information System (INIS)

    Sun Qihe; Yang Jiali; Gao Mingzhong

    2005-01-01

    Objective: To study the dynamic changes of serum levels of several tumor markers after implantation of 125 I seeds as treatment for breast, prostate and lung malignancies. Methods: Serum CA15-3 (in 48 cases of breast cancer), PSA (in 59 cases of prostate cancer) and CYFRA21-1 (in 59 cases of lung cancer) levels were measured with RIA both before and after implantation of 125 I seeds as treatment. Furthermore, dynamic observation on the serum markers levels was carried out every 3 months in ten patients in each category. Results: After treatment, levels of these markers dropped significantly. Dynamic observation revealed that in the 10 cases of breast cancer, the levels of CA15-3 dropped continually. However, in the 10 cases of prostatic cancer, the disease got worse and the PSA levels kept increasing. In the lung cancer group, the CYFRA21-1 levels rose markedly and all patients expired before 9 months. Conclusion: Dynamic observation on changes of serum tumor markers (CA15-3, PSA, CYFRA21-1) levels after 125 I seed implantation treatment was of definite prognostic value. (authors)

  5. Early therapy monitoring of 125I seed interstitial implant in a pancreatic cancer xenograft by 18F-FDG Micro-PET/CT

    International Nuclear Information System (INIS)

    Wang Zhongmin; Liu Yu; Chen Kemin; Lu Jian; Gong Ju; Zheng Yunfeng; Zhang Liyun; Liu Fenju

    2011-01-01

    Objective: To investigate the application value of early evaluation and monitoring of 125 I interstitial implantation in a pancreatic cancer xenograft. Methods: Xenograft models were created by subcutaneous injection of Sw 1990 human pancreatic cancer cell suspensions into the right hind limbs of the immunodeficient BABL/c nude mice. The tumors size were about 8-10 mm after two weeks. The mice were randomly divided into 3 groups,including control group (n=4), empty seed implantation group (n=4) and 125 I implantation group (n=4). Before treatment and one week after treatment, 18 F-FDG Micro-PET/CT scan was performed and then maximum standardized uptake values (SUV max ), mean standardized uptake values (SUV mean ), tumor size and necrosis rate were measured. HE staining and TK1 immunohistochemistry examination were carried out in the paraffin-embedded sample. Results: Before treatment the SUV max and SUV mean values of three groups did not reach statistical significance. One week after treatment the SUV max and SUV mean values of three groups were 3.53±1.20 and 0.57±0.26 vs. 3.83±2.13 and 0.59 ±0.24 vs. 0.29±0.23 and 0.016±0.001, respectively, with a significant difference (F=7.62, P=0.01; F=10.34, P=0.005). The SUV max and SUV mean values of 125 I implant group were significantly lower than empty seed implant group and control group and were significantly lower than before treatment. Before treatment, tumor necrosis rate of three groups were not significantly different. Immunohistochemical staining found the TK1 positive staining index of three groups were respectively (64.25±1.71)%, (62.25±2.22)% and (38.25±1.71)% with statistically significant difference (F=233.67, P<0.001). The TK1 positive staining index of 125 I implant group was significantly lower than empty seed implant group and control group. The SUV max values had some positive correlation with TK1 positive staining index (r=0.85, P=0.001). Conclusions: 18 F-FDG Micro-PET/CT may be useful as a

  6. Edema-induced increase in tumour cell survival for 125I and 103Pd prostate permanent seed implants - a bio-mathematical model

    International Nuclear Information System (INIS)

    Yue Ning; Chen Zhe; Nath, Ravinder

    2002-01-01

    Edema caused by the surgical procedure of prostate seed implantation expands the source-to-point distances within the prostate and hence decreases the dose coverage. The decrease of dose coverage results in an increase in tumour cell survival. To investigate the effects of edema on tumour cell survival, a bio-mathematical model of edema and the corresponding cell killing by continuous low dose rate irradiation (CLDRI) was developed so that tumour cell surviving fractions can be estimated in an edematous prostate for both 125 I and 103 Pd seed implants. The dynamic nature of edema and its resolution were modelled with an exponential function V(T)=V p (1+M exp(-0.693T/T e )) where V p is the prostate volume before implantation, M is the edema magnitude and T e is edema half-life (EHL). The dose rate of a radioactive seed was calculated according to AAPM TG43, i.e. D radical S k Δg(r) φ-bar an /r 2 , where r is the distance between a seed and a given point. The distance r is now a function of time because of edema. The g(r) was approximated as 1/r 0.4 and 1/r 0.8 for 125 I and 103 Pd, respectively. By expanding the mathematical expression of the resultant dose rate in a Taylor series of exponential functions of time, the dose rate was made equivalent to that produced from multiple fictitious radionuclides of different decay constants and strengths. The biologically effective dose (BED) for an edematous prostate implant was then calculated using a generalized Dale equation. The cell surviving fraction was computed as exp(-αBED), where α is the linear coefficient of the survival curve. The tumour cell survival was calculated for both 125 I and 103 Pd seed implants and for different tumour potential doubling time (TPDT) (from 5 days to 30 days) and for edemas of different magnitudes (from 0% to 95%) and edema half-lives (from 4 days to 30 days). Tumour cell survival increased with the increase of edema magnitude and EHL. For a typical edema of a half-life of 10 days

  7. Therapeutic value of 3-D printing template-assisted 125I-seed implantation in the treatment of malignant liver tumors

    Directory of Open Access Journals (Sweden)

    Han T

    2017-07-01

    Full Text Available Tao Han,1,* Xiaodan Yang,1,* Ying Xu,2,* Zhendong Zheng,1,* Ying Yan,2 Ning Wang2 1Department of Oncology, 2Department of Radiotherapy, General Hospital of Shenyang Military Region, Shenyang, China *These authors contributed equally to this work Objective: To explore the therapeutic value of 3-D printing template-assisted 125I-seed implantation in the treatment of malignant liver tumors.Materials and methods: Fifteen liver cancer patients with 47 total lesions were treated with 3-D printing template-assisted radioactive seed implantation (group A, and 25 liver-tumor patients with 66 total lesions were treated with 125I-seed implantation without a template auxiliary (group B. Operation time, in-hospital time, operation complications, dose distribution, and response rate (number were compared between the two groups. Results: Shorter operation times and better dose distribution were observed in group A than in group B, and the differences were statistically significant. The response rate after 2 months was 86.7% (13 of 15 in group A and 84% (21 of 25 in group B; differences between the two groups were not significant.Conclusion: Application of 3-D printing template-assisted radioactive seed implantation in the treatment of malignant liver tumors can help shorten operation time and optimize radiation-dose distribution, is worthy of further study, and has clinical significance. Keywords: brachytherapy, stereotactic techniques, iodine isotopes, liver, carcinoma 

  8. Methodology of quality control for brachytherapy {sup 125}I seeds

    Energy Technology Data Exchange (ETDEWEB)

    Moura, Eduardo S.; Zeituni, Carlos A.; Manzoli, Jose E.; Rostelato, Maria Elisa C.M. [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), Sao Paulo, SP (Brazil)]. E-mail: esmoura@ipen.br

    2007-07-01

    This paper presents the methodology of quality control of {sup 125}I seeds used for brachytherapy. The {sup 125}I seeds are millimeter titanium capsules widely used in permanent implants of prostate cancer, allowing a high dose within the tumour and a low dose on the surrounding tissues, with very low harm to the other tissues. Besides, with this procedure, the patients have a low impotence rate and a small incidence of urinary incontinence. To meet the medical standards, an efficient quality control is necessary, showing values with the minimum uncertainness possible, concerning the seeds dimensions and their respective activities. The medical needles are used to insert the seeds inside the prostate. The needles used in brachytherapy have an internal diameter of 1.0 mm, so it is necessary {sup 125}I seeds with an external maximum diameter of 0.85 mm. For the seeds and the spacer positioning on the planning sheet, the seeds must have a length between 4.5 and 5.0 mm. The activities must not vary more than 5% in each batch of {sup 125}I seeds. For this methodology, we used two ionization chamber detectors and one caliper. In this paper, the methodology using one control batch with 75 seeds manufactured by GE Health care Ltd is presented. (author)

  9. Killing effect of EGFR-TKI combined with 125I seed implantation therapy on ⅢB-Ⅳ stage lung cancer tissue

    Directory of Open Access Journals (Sweden)

    Ai-Sheng Xiang

    2016-12-01

    Full Text Available Objective: To analyze the killing effect of EGFR-TKI combined with 125I seed implantation therapy on ⅢB-Ⅳ stage lung cancer tissue. Methods: A total of 78 patients with ⅢB-Ⅳ stage lung cancer were randomly divided into observation group and control group (n=39, control group received EGFR-TKI treatment and observation group received EGFR-TKI combined with 125I seed implantation therapy. Differences in apoptosis gene, invasion gene and autophagy gene expression in lung tissue were compared between two groups after 1 month of treatment. Results: Apoptosis genes PDCD5, bax and bcl-xS mRNA expression levels in lung tissue of observation group after 1 month of treatment were higher than those of control group while Bag-1, survivin and bcl-xL mRNA expression levels were lower than those of control group; invasion genes CD147, EGFR and DDX17 mRNA expression levels were lower than those of control group while Bin1, E-cadherin and Ovol2 mRNA expression levels were higher than those of control group; autophagy genes ARHI, Beclin1, Atg5, LC3B, pULK and PI3KC3 mRNA expression levels were higher than those of control group. Conclusions: EGFR-TKI combined with 125I seed implantation therapy can enhance the tumor killing effect on patients with ⅢB-Ⅳ stage lung cancer, and contribute to the optimization of overall condition and the extension of survival time.

  10. A dynamic model for the estimation of optimum timing of computed tomography scan for dose evaluation of 125I or 103Pd seed implant of prostate

    International Nuclear Information System (INIS)

    Yue Ning; Dicker, Adam P.; Corn, Benjamin W.; Nath, Ravinder; Waterman, Frank M.

    1999-01-01

    Purpose/Objective: The dosimetric evaluation of permanent 125 I or 103 Pd prostate implant is based on the assumption that both prostate and seeds are static throughout the entire treatment time which lasts months. However, the prostate is often edematous after the surgical implantation of seeds. Therefore, both the volume of the prostate and the seed locations change dynamically as the edema resolves. This effect has impact on the validity of postimplant analysis based upon a CT scan. If a CT scan is taken too early after implantation while there is edema in the prostate, the dose delivered by the implant may be underestimated. If the imaging is delayed too long, the dose may be overestimated. The magnitude of this effect depends on both of the half-life of the isotope used and the half-life and magnitude of the edema. This study describes a dynamic biomathematical model which takes edema into account in calculating the dose delivered by the implant and is used to investigate the optimum time to obtain the postimplant CT scan. Materials and Methods: The dynamic biomathematical model is a numerical integration of the accumulated dose in which the prostate dimensions, the seed locations, and the source strength are all functions of time. The function which describes the change in prostate dimensions and seed locations as a function of time was determined in a separate study by analysis of serial postimplant CT scans. Dose-volume histograms (DVH) of the prostate for the total dose generated by the dynamic model are compared to DVHs generated by CT scans simulated for postimplant intervals ranging from 0 to 300 days after the implantation for 30 different combinations of the magnitude and duration of edema. Results: DVHs of the prostate calculated by taking edema into account show that the time of obtaining a CT scan for postimplant analysis is critical to the accuracy of dose evaluations. The comparison of the DVHs generated by the dynamic model to those generated by

  11. Long term results of ultrasonically guided implantation of 125-I seeds combined with external irradiation in localized prostatic cancer

    Energy Technology Data Exchange (ETDEWEB)

    Iversen, P; Rasmussen, F; Holm, H H [Depts. of Urology and Ultrasound, Herlev Hospital, Univ. of Copenhagen (Denmark)

    1991-01-01

    Transperineal 125-iodine seed implantation guided by transrectal ultrasonography and subsequent external beam irradiation was employed in the treatment of 32 patients with localized prostatic carcinoma (16 poorly differentiated). Follow-up is currently 35-98 months with a median of 65 months. Distant metastases have developed in 18 patients, of whom 11 have died from prostatic cancer. Median change in prostatic volume was a reduction of 35%. Re-biopsy or transurethral resection of the prostate was performed in 25 patients after 1-4 years, revealing still malignant histology in 10 (40%), of whom 8 have developed distant metastases or died from prostatic cancer. Fourteen patients suffered from late complications of which surgical intervention was indicated in five cases. Nine patients are presently free of progression and prostate specific antigen is bigger than 0.5 ng/ml in 8 of these. The future role of ultrasonically guided implantation in the management of prostatic cancer is discussed. (au).

  12. Disease-related effects of perioperative blood transfusions associated with 125I seed implantation for prostate carcinoma

    International Nuclear Information System (INIS)

    Petersen, J.P.; Schellhammer, P.F.; el-Mahdi, A.M.

    1990-01-01

    In some retrospective studies perioperative transfusions during oncologic surgery have been shown to decrease the time interval between surgery and local and/or distant recurrence of cancer. This study examines the disease-related effect, if any, of perioperative blood transfusions among 108 patients with localized carcinoma of the prostate treated by radioactive iodine-125 seed implantation of the prostate and lymphadenectomy. When all subjects were analyzed, there was no statistical difference of local and distant failure between the transfused and nontransfused groups. Patients with well-differentiated tumors had statistically fewer local recurrences (0% vs 22%, p = 0.036) if they were transfused perioperatively. However, the difference in distant metastases (0% vs 11%) was not statistically significant (p = 0.21). In contrast, patients with moderately and poorly differentiated disease receiving transfusions had more local recurrences and metastases, though this was not statistically significant. Our data suggest that there is no obvious evidence that perioperative blood transfusions have an adverse effect on local recurrence or distant metastases for iodine-125 seed implantation of carcinoma of the prostate

  13. Long-term results of ultrasonically guided implantation of 125-I seeds combined with external irradiation in localized prostatic cancer

    DEFF Research Database (Denmark)

    Iversen, P; Rasmussen, F; Holm, H H

    1991-01-01

    Transperineal 125-iodine seed implantation guided by transrectal ultrasonography and subsequent external beam irradiation was employed in the treatment of 32 patients with localized prostatic carcinoma (16 poorly differentiated). Follow-up is currently 35-98 months with a median of 65 months....... Distant metastases have developed in 18 patients, of whom 11 have died from prostatic cancer. Median change in prostatic volume was a reduction of 35%. Re-biopsy or transurethral resection of the prostate was performed in 25 patients after 1-4 years, revealing still malignant histology in 10 (40......%), of whom 8 have developed distant metastases or died from prostatic cancer. Fourteen patients suffered from late complications of which surgical intervention was indicated in five cases. Nine patients are presently free of progression and prostate specific antigen is less than 0.5 ng/ml in 8 of these...

  14. Long-term results of ultrasonically guided implantation of 125-I seeds combined with external irradiation in localized prostatic cancer

    DEFF Research Database (Denmark)

    Iversen, P; Rasmussen, F; Holm, H H

    1991-01-01

    %), of whom 8 have developed distant metastases or died from prostatic cancer. Fourteen patients suffered from late complications of which surgical intervention was indicated in five cases. Nine patients are presently free of progression and prostate specific antigen is less than 0.5 ng/ml in 8 of these......Transperineal 125-iodine seed implantation guided by transrectal ultrasonography and subsequent external beam irradiation was employed in the treatment of 32 patients with localized prostatic carcinoma (16 poorly differentiated). Follow-up is currently 35-98 months with a median of 65 months....... Distant metastases have developed in 18 patients, of whom 11 have died from prostatic cancer. Median change in prostatic volume was a reduction of 35%. Re-biopsy or transurethral resection of the prostate was performed in 25 patients after 1-4 years, revealing still malignant histology in 10 (40...

  15. Comparison of CT- and radiograph-based post-implant dosimetry for transperineal 125I prostate brachytherapy using single seeds and a commercial treatment-planning software

    International Nuclear Information System (INIS)

    Siebert, F.A.; Kohr, P.; Kovacs, G.

    2006-01-01

    Background and purpose: the objective of this investigation was a direct comparison of the dosimetry of CT-based and radiograph-based postplanning procedures for seed implants. Patients and methods: CT- and radiograph-based postplans were carried out for eight iodine-125 ( 125 I) seed implant patients with a commercial treatment-planning system (TPS). To assess a direct comparison of the dosimetric indices (D90, V100, V400), the radiograph-based seed coordinates were transformed to the coordinate system of the CT postplan. Afterwards, the CT-based seed positions were replaced by the radiograph-based coordinates in the TPS and the dose distribution was recalculated. Results: the computations demonstrated that the radiograph-based dosimetric values for the prostate (D p 90, V p 100, and V p 400) were on average lower than the values of the CT postplan. Normalized to the CT postplan the following mean values were found: D p 90: 90.6% (standard deviation [SD]: 9.0%), V p 100: 86.1% (SD: 14.7%), and V p 400: 79.4% (SD: 14.4%). For three out of the eight patients the D p 90 decreased to 90% of the initial CT postplan values. The reason for this dosimetric difference is supposed to be evoked by an error of the reconstruction software used. It was detected that the TPS algorithm assigned some sources to wrong coordinates, partly out of the prostate gland. Conclusion: the radiograph-based postplanning technique of the investigated TPS should only be used in combination with CT postplanning. Furthermore, complex testing procedures of reconstruction algorithms are recommended to minimize calculation errors. (orig.)

  16. Dosimetric and volumetric criteria for selecting a source activity and a source type (125I or 103Pd) in the presence of irregular seed placement in permanent prostate implants

    International Nuclear Information System (INIS)

    Wuu, C.-S.; Ennis, Ronald D.; Schiff, Peter B.; Lee, Eva K.; Zaider, Marco

    2000-01-01

    Purpose: The dosimetric merit of a permanent prostate implant relies on two factors: the quality of the plan itself, and the fidelity of its implementation. The former factor depends on source type and on source strength, while the latter is a combination of skill and experience. The purpose of this study is to offer criteria by which to select a source type ( 125 I or 103 Pd) and activity. Methods and Materials: Given a prescription dose and potential seed positions along needles, treatment plans were designed for a number of seed types and activities, specifically for 125 I with activities ranging from 0.3 to 0.7 mCi, and for 103 Pd with activities in the range of 0.8 to 1.6 mCi. To avoid human planner bias, an automated computerized planning system based on integer programming was used to obtain optimal seed configurations for each seed type and activity. To simulate the effect of seed-placement inaccuracies, random seed-displacement 'errors' were generated for all plans. The displacement errors were assumed to be uniformly distributed within a cube with side equal to 2no. sigmano. The resulting treatment plans were assessed using two volumetric and two dosimetric indices. Results: For 125 I implants a coverage index (CI) of 98.5% or higher can be achieved for all activities (CI is the fraction of the target volume receiving the prescribed or larger dose). The external volume index (EI) (i.e., the amount of healthy tissue, as percentage of the target volume, receiving the prescribed or larger dose) increases from 13.9% to 20% as the activity increases from 0.3 to 0.7 mCi. For implants using 103 Pd, the external volume index increases from 10.2% to 13.9% whenever CI exceeds 98.5%. Volumetric and dosimetric indices (coverage index, external volume index, D90, and D80) are all sensitive to seed displacement, although the activity dependence of these indices is more pronounced for 125 I than for 103 Pd implants. Conclusions: For both isotopes, the lower activities

  17. Evaluation of the dose distribution for prostate implants using various 125I and 103Pd sources

    International Nuclear Information System (INIS)

    Meigooni, Ali S.; Luerman, Christine M.; Sowards, Keith T.

    2009-01-01

    Recently, several different models of 125 I and 103 Pd brachytherapy sources have been introduced in order to meet the increasing demand for prostate seed implants. These sources have different internal structures; hence, their TG-43 dosimetric parameters are not the same. In this study, the effects of the dosimetric differences among the sources on their clinical applications were evaluated. The quantitative and qualitative evaluations were performed by comparisons of dose distributions and dose volume histograms of prostate implants calculated for various designs of 125 I and 103 Pd sources. These comparisons were made for an identical implant scheme with the same number of seeds for each source. The results were compared with the Amersham model 6711 seed for 125 I and the Theragenics model 200 seed for 103 Pd using the same implant scheme.

  18. Application of 125I seed permanent plantation in osseous metastases

    International Nuclear Information System (INIS)

    Zhang Fujun; Wu Peihong; Lu Mingjian; Li Kui; Zhang Liang; Huang Jinhua; Fan Weijun; Zhao Ming; Gu Yangkui; Liu Jian; Wang Junjie

    2007-01-01

    Objective: To evaluate the value of 125 I permanent plantation in treating osseous metastases. Methods: Twenty-two patients with osseous metastases were accepted radioactive seeds 125 I permanent plantation. The curative effect was appraised according to the degree of ostalgia relieving and the changing of the radiology imaging in patients. Results: Accepted radioactive seeds 125 I permanent plantation, relief of pain was obtained and the effective rate is 91% (20/22). However none of the patients showed severe side-effect. Among 32 lesions in 22 cases followed-up by CT in 2 months, 4 obtained CR, 18 obtained PR, 10 NC and 0 PD. The responsive rate was 68.7%. Conclusion: 125 I permanent plantation procedure can be a safe and effective method in treating osseous metastases and obtaining good clinical effects with minimal damage and few complications. (authors)

  19. Combination of multi-disciplinary techniques with 125I seeds in treating malignant obstructive jaundice

    International Nuclear Information System (INIS)

    Du Xueming; Xu Jianhui; Lang Jianhua; Tian Xiurong; Dong Wei

    2008-01-01

    Objective: To explore the effectiveness and safety of the combined multi-disciplinary techniques with 125 I seeds to treat the malignant obstructive jaundice. Methods: 18 cases:of malignant obstructive jaundice were divided into 2 groups. A group with ERBD technique followed by CT-guided interstitial 125 I seeds implantation, B group with 125 I seeds implantation during the operation and gallbladder-intestine anastomosis later on. After 2 months amelioration (CR, PR,SD, PD) of the obstructive jaundice was observed with inspection of liver functions. Results: All cases were ameliorated with 44% patients in group A and 56% patients in group B, showing no significant statistical difference (P>0.05); and the liver functions were also relieved in both groups with no statistical significance (P>0.05). Conclusion: Multi-disciplinary techniques combined with 125 I seeds implantation is effective in the management of the malignant obstructive jaundice. No significant difference for relief and liver function were found between CT-guided and during operation interstitial 125 I seeds implantations, but it seems more quickly relief or recovery was achieved in the latter. (authors)

  20. Effect of 125I seeds and 103Pd stents on proliferation of vascular smooth muscle cells

    International Nuclear Information System (INIS)

    Zhu Jun; Zhu Ruisen

    2004-01-01

    To establish the theoretical and practical base for implementing radioactive stents aft PTCA in order to prevent restenosis, in vitro observation was taken over the effects of 12 '5I-seeds and 103 Pd-implanted stents on the vascular smooth muscle cell (VSMC) proliferation. In vitro VSMC model from guinea-pig aortic arteries was established using adherent cell culture methods. The effects of 125 I-seeds and 103 Pd-implanted stents on the VSMC proliferation, with or without fetal bovine serum (FCS), were investigated through cell counting methods and 3 H-TDR implementation tests. It was shown that (1) 10% FCS significantly promoted the DNA synthesis of VSMC (P 125 I-seeds and 103 Pd-implanted stents inhibited the VSMC DNA synthesis in dose-dependent manner, regardless of 10% FCS inducement. At lower radioactive doses, neither 125 I-seeds (18.5-74 kBq) nor 103 Pd-implanted stents (1.48-2.96 MBq) exhibited distinctive effects on the VSMC DNA synthesis (P>0.05); and (3) 48 hour exposure from 125 I-seeds at 128 kBq or 10 '3Pd-implanted stents at 7.4 MBq did not result in VSMC morphological alteration, but 125 I-seeds at 370 kBq caused cells' morphological changes. Therefore both 125 I-seeds and 103 Pd-implanted stents inhibit the in vitro VSMC DNA synthesis, and the inhibition effects are significantly related to their exposure duration and doses. (authors)

  1. Dosimetric study of permanent prostate brachytherapy utilizing 131Cs, 125I and 103Pd seeds

    International Nuclear Information System (INIS)

    Yang Ruijie; Wang Junjie; Zhang Hongzhi

    2009-01-01

    Objective: To compare the dosimetric differences of permanent prostate brachytherapy utilizing 131 Cs, 125 I and 103 Pd seeds. Methods: Twenty-five patients with T 1 -T 2 c prostate cancer who had previously implanted with 125 I seeds were randomly selected in our study. The patients were re-planned with 131 Cs, 125 I and 103 Pd seeds by using the Prowess Brachytherapy 3.1 planning system to the prescription doses of 115 Gy, 145 Gy and 125 Gy, respectively. The seed strengths were 1.8 U,0.5 U and 1.8 U, respectively. The prostate, prostatic urethra and anterior wall of the rectum were contoured on trans-rectal ultrasound images. PTV was outlined based on the prostate volume with no margin applied. The attempted planning goals were that V 100 (the percentage volume of the prostate receiving at least 100% of the prescription doses)= 95%, D 90 (the minimum percentage dose covering 90% of the prostate volume) ≥100%, and prostatic urethra UD 10 (the maximum percentage dose receiving by 10% of the contoured urethra) ≤150%. For the plan comparison, we also computed prostate V 150 , prostatic urethra UV 120 , rectum RV 100 , and the number of implanted seeds and needles. The significance of the differences was tested using one way analysis of variance. Results: The average V 200 in the 103 Pd, 125 I and 131 Cs plans were 28.7%, 20.9% and 19.6% (F=42.50, P=0.000); the average V 150 were 51.9%, 42.1% and 39.4% (F=26.15, P=0.000); the average UV 120 were 26.9%, 29.5% and 23.8% (F=0.37, P=0.691); and the average rectum RV 100 were 0.31 cm 3 , 0.22 cm 3 and 0.19 cm 3 (F=0.43, P=0.652). For 103 Pd, 125 I and 131 Cs, the average number of implanted seeds per cm 3 prostate were 2.02, 2.01 and 1.87 (F=1.92, P=0.154), and the average number of needles were 33.6, 32.9 and 31.6 (F=0.26,P=0.772). Conclusions: Comparing to 125 I and 103 Pd seeds used in permanent prostate brachytherapy, 131 Cs seeds has better dose homogeneity, and possible better sparing of the urethra and rectum

  2. The use of anisotropic data in 125I prostate implants

    International Nuclear Information System (INIS)

    Fox, R.A.; Haworth, A.; Mina, L.L.

    1997-01-01

    The report recently published by the American Association of Physicists in Medicine (AAPM) Task Group 43 (TG43) recommends the use of a two dimensional dose distribution function for the dosimetry associated with 125 I, 192 Ir and 103 Pd sources. For commercial planning systems that cannot be readily adapted to use a two dimensional function, a point source approximation is provided. The dose distribution around an array of 125 I seeds has been calculated using the two dimensional model and the point source approximation. Isodose distributions through selected planes and dose volume histograms of selected cubic volumes show that differences between the two models for this array are insignificant, particularly in view of the uncertainties associated with using the data which is provided by TG43 for the two dimensional anisotropy function and that it should be retained for planning prostrate treatments with 125 I seeds. It is recommended that each application must be examined separately to establish the extent to which an isotropic dose distribution is applicable

  3. Incidence of seed migration to the chest, abdomen, and pelvis after transperineal interstitial prostate brachytherapy with loose 125I seeds

    International Nuclear Information System (INIS)

    Sugawara, Akitomo; Shigematsu, Naoyuki; Nakashima, Jun; Kunieda, Etsuo; Nagata, Hirohiko; Mizuno, Ryuichi; Seki, Satoshi; Shiraishi, Yutaka; Kouta, Ryuichi; Oya, Mototsugu

    2011-01-01

    The aim was to determine the incidence of seed migration not only to the chest, but also to the abdomen and pelvis after transperineal interstitial prostate brachytherapy with loose 125 I seeds. We reviewed the records of 267 patients who underwent prostate brachytherapy with loose 125 I seeds. After seed implantation, orthogonal chest radiographs, an abdominal radiograph, and a pelvic radiograph were undertaken routinely to document the occurrence and sites of seed migration. The incidence of seed migration to the chest, abdomen, and pelvis was calculated. All patients who had seed migration to the abdomen and pelvis subsequently underwent a computed tomography scan to identify the exact location of the migrated seeds. Postimplant dosimetric analysis was undertaken, and dosimetric results were compared between patients with and without seed migration. A total of 19,236 seeds were implanted in 267 patients. Overall, 91 of 19,236 (0.47%) seeds migrated in 66 of 267 (24.7%) patients. Sixty-nine (0.36%) seeds migrated to the chest in 54 (20.2%) patients. Seven (0.036%) seeds migrated to the abdomen in six (2.2%) patients. Fifteen (0.078%) seeds migrated to the pelvis in 15 (5.6%) patients. Seed migration occurred predominantly within two weeks after seed implantation. None of the 66 patients had symptoms related to the migrated seeds. Postimplant prostate D90 was not significantly different between patients with and without seed migration. We showed the incidence of seed migration to the chest, abdomen and pelvis. Seed migration did not have a significant effect on postimplant prostate D90

  4. Histology study on the dorsal root ganglia of rats with 125I seed brachytherapy at intervertebral foramen

    International Nuclear Information System (INIS)

    Zhang Wenyi; Wang Huixing; Ding Yanqiu; Qu Ximei; Wang Liqin; Liu Zhongchao; Cui Songye; Jiao Ling

    2012-01-01

    Objective: To investigate the effect of the histological changes on rat dorsal root ganglia (DRG) after 125 I seed brachytherapy.Methods Twelve adult male Sprague-Dawley rats (150-180 g each) were randomly divided into 6 groups, 125 I seeds with different activities of 0 (Titanium shell), 14.8, 18.5, 22.2, 25.9 and 29.6 MBq were implanted to 6 groups of rats respectively and the behavioral changes of rats were observed. The rats were killed in different periods after implantation,the morphological changes in DRG and surrounding muscle tissue were observed with an Olympus BX51 optical microscope and then the irradiation doses were estimated. Results: After 125 I seed implantation, the movement function of rats was not affected and the weight of rats gained after 7 days. After the titanium shell implantation, very few mild swelling was induced in neuroganglion cells that still had clear nucleolus and normal cytoplasm. At 14 days after 18.5 MBq seed implantation, cell swelling was more serious and cell dehydrating, nuclear condensation and nuclear fragmentation appeared after 30 days. At 60 days after 29.6 MBq of seed implantation, nuclear dissolution and cytoplasmic shrinkage were induced in a large number of cells.In general, the severity of fibrosis was aggravated with the time post-irradiation and the dose in the muscles around the ganglion. Conclusions: After 125 I seed implantation,the injury degree of DRG tissue is dose-dependent, and the 125 I seed irradiation would have analgesic effect on releasing intractable pain. (authors)

  5. Self-expandable medical memorial metallic stent with 125I seeds for the treatment of esophageal carcinoma: a retrospective analysis

    International Nuclear Information System (INIS)

    Zhang Shuo; Lu Bin

    2011-01-01

    Objective: To discuss the curative effect and safety of the implantation of self-expandable medical memorial metallic stent with 125 I seeds for the treatment of advanced esophageal carcinomas. Methods: Implantation of self-expandable medical memorial metallic stent with 125 I seeds was performed in 32 patients with advanced esophageal canner. The clinical data were retrospectively analyzed. The technical success rate, the operation time, the immediate and mid-term effectiveness, the survival time, the complications, the body weight, the blood picture, the immune indexes, the average hospitalization days and hospitalization expenses were analyzed. Results: The average operation time was (18±5) minutes. Successful stent implantation was achieved in all 32 patients (100%). No 125 I seeds fell off during the procedure. The remission rate of dysphagia was 100%. Esophageal restenosis occurred in four patients, and displacement of the stent was seed in one patient. One month after the treatment, 90% of patients had a Karnofsky performance score over 60. The mean survival time was (8.7±6.6) months. The average hospitalization time was (7.8±3.7) days and the mean hospitalization cost was (12±3) thousand Chinese Yuan. Conclusion: For the treatment of esophageal carcinomas, the implantation of self-expandable medical memorial metallic stent with 125 I seeds is safe, effective and simple. This treatment can markedly improve the symptom of dysphagia and significantly prolong the patient's survival time. (authors)

  6. Prophylactic urethral stenting with Memokath® 028SW in prostate cancer patients undergoing prostate 125I seed implants: phase I/II study

    Directory of Open Access Journals (Sweden)

    Samuel T. Chao

    2011-03-01

    Full Text Available Purpose: To study the feasibility/toxicity of urethral stenting with the Memokath® 028SW stent in patients undergoing prostate implant (PI for prostate adenocarcinoma. Material and methods: An Investigational Device Exemption from the Food and Drug Administration (FDA and institutional review board (IRB approval were obtained. Twenty patients enrolled. Baseline American Urological Association (AUA score was obtained prior to PI. Follow-up information was obtained with weekly phone calls for the first 12 weeks and biweekly calls for the next 12 weeks to assess toxicity and AUA score. Removal of the stent was planned at six months after PI, or earlier due to excessive toxicity/patient request. Results: Median age was 66.5 years. The median prostate volume was 39 cc (range: 10-90. The median baseline AUA score was 7.5 (range: 1-21. Three patients required intermittent self-catheterization (ISC within 3 days after PI. No patients required ISC beyond day 3 after PI. The median duration of ISC was 1 day (range: 1-2. AUA scores returned to baseline values 6 weeks after PI. The week 6 AUA score was 10 (range: 4-16. Seven patients (35% underwent early removal because of patient preference. The reasons were: incontinence (n = 3, discomfort (n = 2, hematuria (n = 1, and obstructive symptoms (n = 1. The median time of stent removal in these patients was 13.9 weeks (range: 0.9-21.4. Thirteen patients (65% had ISC and/or urinary catheterization post stent removal. Median time for ISC use was 10 days (range: 1-90. Conclusions: Urethral stenting with Memokath® in patients undergoing PI was feasible, but resulted in relatively high rate of urinary incontinence and discomfort. Given the adverse effects experienced by patients of this study, further studies should focus only on patients with highest risk of urinary obstruction from PI or those with obstruction needing ISC.

  7. Self-expandable stent loaded with {sup 125}I seeds: Feasibility and safety in a rabbit model

    Energy Technology Data Exchange (ETDEWEB)

    Guo Jinhe [Department of Radiology, Zhong-Da Hospital, Southeast University, 87 Dingjiaqiao Road, Nanjing 210009 (China); Teng Gaojun [Department of Radiology, Zhong-Da Hospital, Southeast University, 87 Dingjiaqiao Road, Nanjing 210009 (China)]. E-mail: gjteng@vip.sina.com; Zhu Guangyu [Department of Radiology, Zhong-Da Hospital, Southeast University, 87 Dingjiaqiao Road, Nanjing 210009 (China); He Shicheng [Department of Radiology, Zhong-Da Hospital, Southeast University, 87 Dingjiaqiao Road, Nanjing 210009 (China); Deng Gang [Department of Radiology, Zhong-Da Hospital, Southeast University, 87 Dingjiaqiao Road, Nanjing 210009 (China); He Jie [Department of Radiology, Zhong-Da Hospital, Southeast University, 87 Dingjiaqiao Road, Nanjing 210009 (China)

    2007-02-15

    Objective: To evaluate technical feasibility and acute and subacute radiotolerance of a self-expandable stent loaded with {sup 125}I seeds in the rabbit esophagus. Methods: A self-expandable stent designed for esophageal application was made of 0.16 mm nitinol wire and loaded with {sup 125}I seeds (CIAE-6711). Twenty-seven stents with three different radioactive dosages (n = 9 in each dosage group) were implanted in the esophagus of healthy rabbits, while nine stents alone were used as controls. The stents were perorally deployed into the esophagus under fluoroscopic guidance. Radiological follow-up included plain chest film, CT scan, and barium esophagography which were undertaken in all rabbits of each group at 2, 4, and 8 weeks, respectively, which were correlated to histopathological findings. The stented esophageal segments along with their adjacent tissues were harvested for histopathological examinations. Results: The stent was successfully deployed into the targeted esophageal segment in all rabbits. Neither {sup 125}I seeds dislodged from the stent during the deployment, nor they did during the follow-up period. The greatest (16.2 Gy) absorbed dose was found in the tissue 10 mm from {sup 125}I seeds at 8 weeks. Slight epithelial hyperplasia on the stent surface and submucosal inflammatory process developed at 2 weeks, which reached the peak at 8 weeks after the procedure. Significant thickness of the esophageal muscular layer was found at 8 weeks only in the groups with {sup 125}I seeds. On radiologic follow-up, moderate strictures on both ends of the stents developed at 4 weeks and became severe at 8 weeks after the procedure in all groups. Conclusion: Deployment of a self-expandable stent loaded with {sup 125}I seeds is technically feasible and safe within the first 8 weeks. Acute and subacute radiotolerance of the treated esophagus and its adjacent tissues by {sup 125}I seeds is well preserved in a healthy rabbit model.

  8. [Technique of intraoperative planning in prostatic brachytherapy with permanent implants of 125I or 103Pd].

    Science.gov (United States)

    Prada Gómez, Pedro José; Juan Rijo, Germán; Hevia Suarez, Miguel; Abascal García, José María; Abascal García, Ramón

    2002-12-01

    Prostatic brachytherapy with permanent 125I or 123Pd seeds implantation is a therapeutic option for organ-confined prostate cancer. We analyze the technique based on previous planning, our current intraoperative planning procedure and the reasons that moved us to introduce this change. Changes in prostate volume and spatial localization observed between previous planning and intraoperative images, and possible difficulties for seed implantation due to pubic arch interference are some of the reasons that induce us to change technique. Before the operation, we calculate the prostatic volume by transrectal ultrasound; with this information we determine the total implant activity following Wu's nomogram, and per-seed activity; therefore, it is an individual process for each patient. We perform a peripheral implant, placing 75-80% of the seeds within the peripheral prostatic zone, generally through 12-15 needles, the rest of the seeds are placed in the central prostatic zone using a maximum of 3-4 needles in high volume prostates. The day of intervention, after positioning and catheter insertion, volumetry is re-checked. Ultrasound images (from base to apex every 5 mm) are transferred to the planner were a suitable seed distribution is determined. Implantation is then performed placing all needles unloaded, and then intraoperative post-planning to allow us to check implant precision is performed after cistoscopically check that there is no urethral or bladder penetration by any needle. We finish with the insertion of seeds into the prostate. Total time for the procedure is around 90 minutes. Intraoperative planning is an additional step for the treatment of prostate cancer with permanent seeds brachytherapy, which avoids the disadvantages of previous planning and improves tumor inclusion in the ideal irradiation dose area, which will translate into better local disease control.

  9. Development of procedure using plasma welding process to produce 125I seeds

    International Nuclear Information System (INIS)

    Feher, Anselmo

    2006-01-01

    The prostate cancer, which is the second cause of death by cancer in men, overcome only by lung cancer, is a problem of public health in Brazil. Brachytherapy is among the possible available treatments for prostate cancer, in which small seeds containing 125 I radioisotope are implanted in the prostate. The seed consists of a titanium sealed capsule with 0.8 mm external diameter and 4.5 mm length, containing a central silver wire with adsorbed 125 I. The plasma arc welding is one of the viable techniques for the sealing process. The equipment used in this technique is less costly than in other processes. The main objective of this work was the development and the validation of the welding procedure using plasma welding process and the elaboration of a sealing routine according to Good Manufacturing Practices. The development of this work has presented the following phases: cut and cleaning of the titanium material, determination of the welding parameters, development of a device for holding the titanium tube during the welding process, validation of sealed sources according to ISO 2919 Sealed Radioactive Sources - General Requirements and Classification, leakage test according to ISO 9978 Sealed Radioactive Sources - Leakage Test Methods and metallographic assays. The developed procedure, to seal 125 I seeds using plasma welding process, has shown to be efficient, satisfying all the established requirements of ISO 2919. The results obtained in this work have given the possibility to establish a routine production process according to the orientations presented in resolution RDC number 59 - Good Manufacturing Practices do Medical Products of the ANVISA - Brazilian Nacional Agency of Sanitary Surveillance. (author)

  10. Relative biological effectiveness of 125I seeds for low-dose-rate irradiation of PANC-1

    International Nuclear Information System (INIS)

    Wang Jidong; Wang Junjie; Zhuang Hongqing; Liao Anyan; Zhao Yong

    2008-01-01

    Objective: To investigate the relative biological effectiveness(RBE) of National Model 6711 125 I seeds and the response patterns of PANC-1 exposed to 125 I seeds irradiation. Methods: PANC-1 cells in exponential growth were irradiated at initial dose rate of 2.59 cGy/h in vitro and exposed to 1, 2, 4, 6, 8 and 10 Gy. Meanwhile, the other part of cells were exposed to the same doses by 60 Co at dose rate of 2.21 Gy/min. After irradiation, the cells were stained by trypan blue to measure the cellular mortality rate and to compare the changes along with plating times of 12, 24, 48 and 72 h after 4 Gy. The colonies were counted to obtain the plating efficiencies by colony-forming assay and the cell surviving faction was calculated to plot cell survival curves, and RBE of 125 I seeds relative to 60 Co was determined. Results: The cell death rate for continuous low- dose-rate (LDR) irradiation by 125 I seeds was greater than 60 Co at the same doses above or equal to 4 Gy. After 4 Gy irradiation, the cellular mortality rates were increased with times. The difference was significant between 125 I seeds and 60 Co. The survival fractions of 125 I were lower than those of 60 Co, and the RBE of 125 I relative to 60 Co was determined to be 1.45. Conclusion: The cell-killing effects for continuous low-dose-rate (LDR) irradiation by 125 I seeds are greater than acute high-dose-rate of 60 Co. (authors)

  11. Study on apoptosis of prostate cancer cell induced by 125I seed irradiation

    International Nuclear Information System (INIS)

    Liao Anyan; Wang Junjie; Wang Jidong; Zhuang Hongqing; Zhao Yong

    2007-01-01

    Objective: To explore the mechanism of apoptosis induced by 125 I seed irradiation on PC3 cells. Methods: Human prostate cancer cell line PC3 was treated by irradiation of 125 I (2.77 cGy/h) with various dose. Agarose gel electrophoresis of DNA and flows cytometry were used to detect the apoptosis of PC3 cells and indirect immunofluorescence assay was used to detect the expression of Bcl-2. The activity of Caspase-3 was measured by Caspase Colorimetric Assay Kits. Results: Apoptosis of PC3 cells could be efficiently induced by 125 I seed irradiation. The apoptotic peaks were found by flow cytometry and DNA ladder appeared on 1.8% agarose gel. The activity of Caspase-3 on PC3 cells treated by 125 I seed irradiation was not changed significantly. Bcl-2 gene expression was down-regulated with the sample concentration increased. Conclusion: 125 I irradiation can induce the apoptosis of PC3 cells and the mechanism of apoptosis is related with down regulation of Bcl-2 gene expression and is not related with Caspase-3 activity. (authors)

  12. Dosimetry and treatment planning of Occu-Prosta 125I seeds for intraocular lesions

    International Nuclear Information System (INIS)

    Chaudhari, Suresh; Deshpande, Sudesh; Anand, Vivek; De, Sandeep; Kannan, V.; Saxena, Sanjay; Dash, A.; Basu, Mahua; Samant, Preetam

    2008-01-01

    Intraocular malignant lesions are frequently encountered in clinical practice. Plaque brachytherapy represents an effective means of treatment for intraocular lesions. Recently Radiopharmaceutical Division, BARC, Mumbai, has indigenously fabricated reasonable-cost 125 I sources. Here we are presenting the preliminary experience of dosimetry of sources, configuration of treatment planning system (TPS) and quality assurance (QA) for eye plaque therapy with Occu-Prosta 125 I seeds, treated in our hospital, for a patient with ocular lesions. 125 I seeds were calibrated using well-type chamber. BrachyVision TPS was configured with Monte Carlo computed radial dose functions and anisotropy functions for 125 I sources. Dose calculated by TPS at different points in central axis and off axis was compared with manually calculated dose. Eye plaque was fabricated of 17 karat pure gold, locally. The seeds were arranged in an outer ring near the edge of the plaque and in concentric rings throughout the plaque. The sources were manually digitized on the TPS, and dose distribution was calculated in three dimensions. Measured activity using cross-calibrated well-type chamber was within ± 10% of the activity specified by the supplier. Difference in TPS-calculated dose and manually calculated dose was within 5%. Treatment time calculated by TPS was in concordance with published data for similar plaque arrangement. (author)

  13. 125I Monotherapy Using D90 Implant Doses of 180 Gy or Greater

    International Nuclear Information System (INIS)

    Kao, Johnny; Stone, Nelson N.; Lavaf, Amir; Dumane, Vishruta; Cesaretti, Jamie A.; Stock, Richard G.

    2008-01-01

    Purpose: The purpose of this study was to characterize the oncologic results and toxicity profile of patients treated with 125 I implants using the dose delivered to 90% of the gland from the dose-volume histogram (D90) of greater than 144 Gy. Methods and Materials: From June 1995 to Feb 2005, a total of 643 patients were treated with 125 I monotherapy for T1-T2 prostate cancer with a D90 of 180 Gy or greater (median, 197 Gy; range, 180-267 Gy). Implantations were performed using a real-time ultrasound-guided seed-placement method and intraoperative dosimetry to optimize target coverage and homogeneity by using modified peripheral loading. We analyzed biochemical disease-free survival (bDFS) of 435 patients who had a minimum 2-year prostate-specific antigen follow-up (median follow-up, 6.7 years; range, 2.0-11.1 years). Results: Five-year bDFS rates for the entire cohort using the American Society for Therapeutic Radiology and Oncology and Phoenix definitions were 96.9% and 96.5%, respectively. Using the Phoenix definition, 5-year bDFS rates were 97.3% for low-risk patients and 92.8% for intermediate/high-risk patients. The positive biopsy rate was 4.1%. The freedom rate from Grade 2 or higher rectal bleeding at 5 years was 88.5%. Acute urinary retention occurred in 10.7%, more commonly in patients with high pretreatment International Prostate Symptom Scores (p < 0.01). In patients who were potent before treatment, 73.4% remained potent at 5 years after implantation. Conclusions: Patients with a minimum D90 of 180 Gy had outstanding local control based on prostate-specific antigen control and biopsy data. Toxicity profiles, particularly for long-term urinary and sexual function, were excellent and showed that D90 doses of 180 Gy or greater performed using the technique described were feasible and tolerable

  14. The biological effect of 125I seed continuous low dose rate irradiation in CL187 cells

    Directory of Open Access Journals (Sweden)

    Zhuang Hong-Qing

    2009-01-01

    Full Text Available Abstract Background To investigate the effectiveness and mechanism of 125I seed continuous low-dose-rate irradiation on colonic cell line CL187 in vitro. Methods The CL187 cell line was exposed to radiation of 60Coγ ray at high dose rate of 2 Gy/min and 125I seed at low dose rate of 2.77 cGy/h. Radiation responses to different doses and dose rates were evaluated by colony-forming assay. Under 125I seed low dose rate irradiation, a total of 12 culture dishes were randomly divided into 4 groups: Control group, and 2, 5, and 10 Gy irradiation groups. At 48 h after irradiation, apoptosis was detected by Annexin and Propidium iodide (PI staining. Cell cycle arrests were detected by PI staining. In order to investigate the influence of low dose rate irradiation on the MAPK signal transduction, the expression changes of epidermal growth factor receptor (EGFR and Raf under continuous low dose rate irradiation (CLDR and/or EGFR monoclonal antibodies were determined by indirect immunofluorescence. Results The relative biological effect (RBE for 125I seeds compared with 60Co γ ray was 1.41. Apoptosis rates of CL187 cancer cells were 13.74% ± 1.63%, 32.58% ± 3.61%, and 46.27% ± 3.82% after 2 Gy, 5 Gy, and 10 Gy irradiation, respectively; however, the control group apoptosis rate was 1.67% ± 0.19%. G2/M cell cycle arrests of CL187 cancer cells were 42.59% ± 3.21%, 59.84% ± 4.96%, and 34.61% ± 2.79% after 2 Gy, 5 Gy, and 10 Gy irradiation, respectively; however, the control group apoptosis rate was 26.44% ± 2.53%. P 2/M cell cycle arrest. After low dose rate irradiation, EGFR and Raf expression increased, but when EGFR was blocked by a monoclonal antibody, EGFR and Raf expression did not change. Conclusion 125I seeds resulted in more effective inhibition than 60Co γ ray high dose rate irradiation in CL187 cells. Apoptosis following G2/M cell cycle arrest was the main mechanism of cell-killing effects under low dose rate irradiation. CLDR could

  15. Effects of gold and silver backings on the dose rate around an 125I seed

    International Nuclear Information System (INIS)

    Cygler, J.; Szanto, J.; Soubra, M.; Rogers, D.W.

    1990-01-01

    Measurements of the effect of either gold or silver backing on the dose rate around an 125I seed were performed using a Therados RFA7 dosimetry system and a small diode detector which was 2.5 mm in diameter and 0.06 mm thick. It was found that the presence of the gold or silver backing modifies the diode response on the side of the 125I seed away from the backing. The effect depends on the backing material and the distance from the seed. There is a small increase close to the gold backing but a decrease further away. This decrease at distances greater than 10 mm from the seed is uniformly 10%, the same as found when the seed is backed by air. There is an increase of up to 25% observed with silver backing the seed and this increase remains significant more than 30 mm from the seed. When the response increases, the results are hard to interpret quantitatively because of variations in the diode response per unit dose with photon energy and extreme sensitivity to geometric changes. Nonetheless, except for the increase at close distances with the gold, the results are in agreement with EGS4 Monte Carlo photon transport simulations which are for a simplified geometry and account for x-ray fluorescence from the K-shell. Furthermore, the increase in the gold-backed case is qualitatively explained by Williamson's Monte Carlo calculations which take into account the L-shell fluorescent x-rays from gold

  16. Influence of 125I seed interstitial brachytherapy on recovery of facial nerve function

    International Nuclear Information System (INIS)

    Song Tieli; Zheng Lei; Zhang Jie; Cai Zhigang; Yang Zhaohui; Yu Guangyan; Zhang Jianguo

    2010-01-01

    Objective: To study the influence of 125 I seed interstitial brachytherapy in parotid region on the recovery of facial nerve function. Methods: A total of the data of 21 patients with primary parotid carcinoma were treated with resection and 125 I interstitial brachytherapy. All the patients had no facial palsy before operation and the prescribed dose was 60 Gy. During 4 years of follow-up, the House-Brackmann grading scales and ENoG were used to evaluate the function of facial nerve. According to the modified regional House-Brackmann grading scales, the facial nerve branches of patients in affected side were divided into normal and abnormal groups, and were compared with those in contra-lateral side. Results: Post-operation facial palsy occurred in all the patients, but the facial palsy recovered within 6 months. The latency time differences between affected side and contralateral side were statistically significant in abnormal group from 1 week to 6 months after treatment (t=2.362, P=0.028), and were also different in normal group 1 week after treatment (t=2.522, P=0.027). Conclusions: 125 I interstitital brachytherapy has no influence on recovery of facial nerve function after tumor resection and no delayed facial nerve damage. (authors)

  17. Urinary morbidity with a modified peripheral loading technique of transperineal 125i prostate implantation

    International Nuclear Information System (INIS)

    Brown, Douglas; Colonias, Athanasios; Miller, Ralph; Benoit, Ronald; Cohen, Jeffrey; Arshoun, Youssef; Galloway, Michael; Karlovits, Stephen; Wu, Andrew; Johnson, Mark; Quinn, Annette; Kalnicki, Shalom

    2000-01-01

    Purpose: Analysis of urinary morbidity within the first 12 months following a modified peripheral loading technique for permanent transperineal transrectal ultrasound (TRUS) guided 125 I prostate implantation and comparison of urinary morbidity with various clinical and implant parameters. Materials and Methods: Between October 1, 1996, and March 11, 1998, 87 patients with favorable, early stage prostate cancer were treated with permanent transperineal TRUS guided 125 I prostate implantation. A peripheral loading technique was utilized for source placement with 75-80% source distribution in the periphery and 20-25% source distribution centrally. A mean total activity of 38 mCi of 125 I was implanted (range, 19-66 mCi). The mean source activity was 0.43 mCi/source (range, 0.26-0.61 mCi/source) and the mean number of sources implanted was 88 (range, 56-134). The minimum prescribed dose to the prostate was 145 Gy. The median D 90 , V 100 , and V 150 were 152 Gy (range, 104-211 Gy), 92% (range, 71-99%), and 61% (range, 11-89%), respectively. The median follow-up time was 19 months (range, 12-29 months). Urinary morbidity was scored at 3 weeks and then at 3-month intervals for the first 2 years using a modified Radiation Therapy Oncology Group (RTOG) grading system (scale 0-5). Results: Most patients developed at least minor urinary symptoms with frequency or nocturia being the most common. Overall, 79% (69/87) of patients experienced urinary morbidity with 21% (18/87) reporting no symptoms. The incidence of overall Grade 1 urinary morbidity was 37% (32/87); Grade 2 morbidity was 37% (32/87); and Grade 3 morbidity was 6% (5/87). There was no Grade 4 or 5 morbidity. The incidence of Grade 0 frequency/nocturia was 36% (31/87); Grade 1 was 33% (29/87); Grade 2 was 30% (26/87); and Grade 3 was 1% (1/87). Grade 0 dysuria was seen in 56% (49/87) of patients; 32% (28/87) had Grade 1; 10% (9/87) Grade 2; and 1% (1/87) Grade 3 dysuria. Most urinary symptoms started a few weeks

  18. 125I implants as an adjuvant to surgery and external beam radiotherapy in the management of locally advanced head and neck cancer

    International Nuclear Information System (INIS)

    Martinez, A.; Goffinet, D.R.; Fee, W.; Goode, R.; Cox, R.S.

    1983-01-01

    125 I seeds either individually placed or inserted into absorbable Vicryl suture carriers were utilized in conjunction with surgery and external beam radiotherapy in an attempt to increase local control rates in patients with advanced oropharyngeal and laryngopharyngeal cancers (T3-T4, N2-N3), massive cervical lymphadenopathy (N3) and an unknown primary site and locally recurrent head and neck cancers. Forty-eight patients were treated with 55 implants. The carotid artery was implanted in 15 patients, while seven patients had seeds inserted into the base of the skull region, and another three patients had implants near cranial nerves. Eighteen of the 48 patients were treated for cure. The actuarial survival at five years in this subgroup was 50%. The overall local control in the head and neck area was 58%. In this group no patients to date have had a local failure in the implanted volume. Seventeen patients with comparable stage of disease treated prior to 1974 with curative intent without 125 I implants were analyzed retrospectively for comparison with the implanted patients. The actuarial survival of these patients was 18% and the overall head and neck control was 21%. These differences are statistically significant at a P value of 0.01 and 0.007, respectively. Seventeen patients received implants for local recurrence. The local control in the head and neck area was 50%; however, the 2.5 year actuarial survival was only 17%. The complication rate was 11% (six of 55 implants). The improved survival, the high local control, and the minimal complication rates in this series makes the intraoperative implantation of 125 I seeds and effective adjunctive treatment to surgery and external beam irradiation

  19. Development of procedure using plasma welding process to produce {sup 125}I seeds; Desenvolvimento de procedimento utilizando processo de soldagem plasma para confeccao de sementes de {sup 125}I

    Energy Technology Data Exchange (ETDEWEB)

    Feher, Anselmo

    2006-07-01

    The prostate cancer, which is the second cause of death by cancer in men, overcome only by lung cancer, is a problem of public health in Brazil. Brachytherapy is among the possible available treatments for prostate cancer, in which small seeds containing {sup 125}I radioisotope are implanted in the prostate. The seed consists of a titanium sealed capsule with 0.8 mm external diameter and 4.5 mm length, containing a central silver wire with adsorbed {sup 125}I. The plasma arc welding is one of the viable techniques for the sealing process. The equipment used in this technique is less costly than in other processes. The main objective of this work was the development and the validation of the welding procedure using plasma welding process and the elaboration of a sealing routine according to Good Manufacturing Practices. The development of this work has presented the following phases: cut and cleaning of the titanium material, determination of the welding parameters, development of a device for holding the titanium tube during the welding process, validation of sealed sources according to ISO 2919 Sealed Radioactive Sources - General Requirements and Classification, leakage test according to ISO 9978 Sealed Radioactive Sources - Leakage Test Methods and metallographic assays. The developed procedure, to seal {sup 125}I seeds using plasma welding process, has shown to be efficient, satisfying all the established requirements of ISO 2919. The results obtained in this work have given the possibility to establish a routine production process according to the orientations presented in resolution RDC number 59 - Good Manufacturing Practices do Medical Products of the ANVISA - Brazilian Nacional Agency of Sanitary Surveillance. (author)

  20. Permanent 125I-seed prostate brachytherapy: early prostate specific antigen value as a predictor of PSA bounce occurrence

    Directory of Open Access Journals (Sweden)

    Mazeron Renaud

    2012-03-01

    Full Text Available Abstract Purpose To evaluate predictive factors for PSA bounce after 125I permanent seed prostate brachytherapy and identify criteria that distinguish between benign bounces and biochemical relapses. Materials and methods Men treated with exclusive permanent 125I seed brachytherapy from November 1999, with at least a 36 months follow-up were included. Bounce was defined as an increase ≥ 0.2 ng/ml above the nadir, followed by a spontaneous return to the nadir. Biochemical failure (BF was defined using the criteria of the Phoenix conference: nadir +2 ng/ml. Results 198 men were included. After a median follow-up of 63.9 months, 21 patients experienced a BF, and 35.9% had at least one bounce which occurred after a median period of 17 months after implantation (4-50. Bounce amplitude was 0.6 ng/ml (0.2-5.1, and duration was 13.6 months (4.0-44.9. In 12.5%, bounce magnitude exceeded the threshold defining BF. Age at the time of treatment and high PSA level assessed at 6 weeks were significantly correlated with bounce but not with BF. Bounce patients had a higher BF free survival than the others (100% versus 92%, p = 0,007. In case of PSA increase, PSA doubling time and velocity were not significantly different between bounce and BF patients. Bounces occurred significantly earlier than relapses and than nadir + 0.2 ng/ml in BF patients (17 vs 27.8 months, p Conclusion High PSA value assessed 6 weeks after brachytherapy and young age were significantly associated to a higher risk of bounces but not to BF. Long delays between brachytherapy and PSA increase are more indicative of BF.

  1. Clinical effects of FP and Addie injection combined with 125I seed implantation in treating advanced primary liver cancer%FP+艾迪注射液联合125I粒子植入治疗中晚期原发性肝癌的临床研究

    Institute of Scientific and Technical Information of China (English)

    张大为; 何津; 吴会静; 张海光; 张青芸; 马一夫; 马龙滨; 陈宝明

    2016-01-01

    Objective To observe the clinical effects of FP (5-fluorouracil and cisplatin) and Addie injection combined with 125I seed implantation in treating advanced primary liver cancer. Methods Ninety-five patients with pri-mary liver cancer who were admitted in People's Hospital of Tangshan City between February 2012 and July 2015 were selected as subjects and were randomized into observation group (n=50) and control group (n=45) by random number ta-ble method. The control group was treated with FP combined with 125I seed implantation. On the basis, the observation group was treated additionally with Addie injection, for 2 courses of treatment. The clinical remission rate, Karnofsky Performance Scale (KPS) scores and peripheral blood white blood cell count before and after treatment, incidence of ad-verse reactions, 1-year and 2-year survival rates were compared between the two groups. Results After treatment, the clinical remission rate in observation group (36.0%) was significantly higher than that in control group of 17.8%, P0.05). After treatment, KPS scores of the two groups were increased to (85.3±5.0) and (79.3±5.2) respectively, while peripheral blood white blood cell count were decreased to (5.0±1.6)×109/L and (3.1 ± 1.3) × 109/L, respectively, with statistically significant difference compared with those before treatment and be-tween the two groups (all P0.05);治疗后,观察组与对照组患者的KPS评分分别升高至(85.3±5.0)分、(79.3±5.2)分,外周血白细胞计数分别减少至(5.0±1.6)×109/L、(3.1±1.3)×109/L,较治疗前均改善明显,且观察组治疗后的KPS评分、外周血白细胞计数均高于对照组,差异均有统计学意义(P<0.05).结论 FP+艾迪注射液联合125I粒子植入治疗中晚期原发性肝癌能明显提高临床缓解率与KPS评分,抑制白细胞减少,生存时间得以延长,值得临床推广应用.

  2. 125I implantation combined with chemotherapy for treatment of local recurrent stage Ⅲ non-small cell lung cancer

    International Nuclear Information System (INIS)

    Luo Honglei; Yu Xiaojuan; Li Jin; Chen Xiaofei; He Jingdong

    2013-01-01

    Objective: To investigate the associated effect of 125 I implantation plus chemotherapy in local recurrent stage Ⅲ NSCLC patients. Methods: From January 2006 to January 2009, 34 patients documented with local recurrent stage Ⅲ NSCLC were divided into two groups by random number table. The treatment group was treated with 125 I permanent implantation combined with DP regimen (docetaxel 60 mg/m 2 + cisplatinum 75 mg/m 2 ), while the control group received only DP chemotherapy. According to the TPS, the treatment group received CT-guided percutaneous implantation of 125 I seeds with a particle activity of 2.22 ×10 7 -2.59 × 10 7 Bq. The prescribed dose was in the range of 90-110 Gy and the postoperatively matched peripheral dose (mPD) and D 90 were verified by TPS. The control group received a DP chemotherapy regime for 4 cycles after the procedure. This study was approved by the ethics committee,and all patients signed informed consents. The follow up time was up to disease progression. Kaplan-Meier survival analysis was used to describe the local lesion control (LLC) time and progression free survival (PFS). Log-rank test was used in the comparison of the survival rates between the two groups. Fisher's exact test was used to analyze the differences of CR rate and recent efficiency between two groups. Results: In the treatment group, postoperative mPD was 93.9-130.4 (M 116.7) Gy, and D 90 was 103.6-148.2 (M 130.6) Gy. The LLC time was 4.7 to 24.0 months with a median of 11.6 (95% CI: 8.7-14.6) months. In two cases, there was no recurrence during the follow-up time of 24 months.PFS was 4.7 to 24.0 months with a median of 10.5 (95% CI: 7.4-13.6) months. The recent effective rate of the treatment group was 64.7% (11/17).CR, PR, SD and PD were 41.2% (7/17), 23.5% (4/17), 23.5% (4/17) and 11.8% (2/17), respectively. In the control group, the LLC time was 4.5 to 11.4 months with a median of 7.5 (95 % CI: 6.7-8.3) months, and the median of PFS was 6.5 (4

  3. Dosimetric studies, spectrometric, radiographic, metallographic of a new argentinean seed of 125 I used in brachytherapy

    International Nuclear Information System (INIS)

    Pirchio, R.; Saravi, M.; Banchik, D.; Munoz, C.

    2006-01-01

    A new source of 125 I model Braquibac TM has been developed in Argentina for applications in interstitial brachytherapy. The AAPM Task Group 43 (TG-43) recommends that dosimetric characteristics of new sources of brachytherapy of Iodine-125 have been theoretically and experimentally determined before its clinical use. The objectives outlined in this work were the study of the design of the new seed, the calculation of dosimetric parameters and the photons spectra analysis. Its were carried out radiographic and metallographic studies to determine the physical characteristics of the source. For the realization of the dosimetric calculations it was used the Monte Carlo code MCNP5. Values of the radial dose function, g(r), of the constant of dose rate, Λ, of the function of anisotropy of two dimensions, F(r, θ), of the factor and constant of anisotropy its were obtained simulating the source in water according to the recommended methodology in TG-43. The constant of dose rate is similar to 0,880 ± 0,080 c Gy h -1 U -1 . The kerma in air rate of reference, S K , was calculated as 1,036 c Gy cm 2 h -1 mCi -1 simulating the seed in dry air. Its were carried out spectrometric studies using a semiconductor planar detector of HPGe (high purity germanium). Photons spectra showed characteristic x-rays of 125 I with energies of 27,20 keV, 27,47 keV, 31 keV and 31,70 keV gamma photons of 35,5 keV, and x-ray fluorescent coming from the silver nucleus of 22,10 keV, 24,94 keV and 25,45 keV. The angular dependence of the intensity of photons around the seed and in air it was analyzed with the planar detector. This was carried out to study the anisotropy in the photons flow due to variation in the thickness of the titanium wall and of the welding, movements of the silver tube inside the source and deposition of the radioactive material on the silver tube. (Author)

  4. A proteomics analysis for certain signature proteins of rabbit lacrimal passages after 125I seeds brachytherapy

    International Nuclear Information System (INIS)

    Li Dandan; Liu Lin; Gao Shi; Qi Liangchen; Ma Qingjie; Jin Longyun

    2010-01-01

    To search for certain signature proteins and the expression profiles in lacrimal passage stenosis, rabbit models of lacrimal passage stenosis were treated by 125 I seed brachytherapy. All the signature proteins were separated by two-dimensional electrophoresis, and identified by mass spectrometry. The results show that the up-regulated proteins are peptidyl-prolyl cis-trans isomerase A (PPIase A), and epidermal fatty acid-binding protein (E-FABP), while the down-regulated proteins are myosin light chain 1 (isomer of skeletal muscle), myosin light polypeptide 6 (isomer 1 of smooth muscle and non-muscle), myosin light chain 1 (isomer of slow-twitch muscle A), isomer 2 of ERC protein 2, and α-crystalline family protein. The proteins may play a role in healing the wound and regulating synaptic active zone of neurons due to correlation to cell apoptosis, proliferation and migration of smooth muscle cell. These provide molecular mechanism for preventing stenosis and restenosis of lacrimal passage. (authors)

  5. Effect of improved TLD dosimetry on the determination of dose rate constants for 125I and 103Pd brachytherapy seeds

    International Nuclear Information System (INIS)

    Rodriguez, M.; Rogers, D. W. O.

    2014-01-01

    Purpose: To more accurately account for the relative intrinsic energy dependence and relative absorbed-dose energy dependence of TLDs when used to measure dose rate constants (DRCs) for 125 I and 103 Pd brachytherapy seeds, to thereby establish revised “measured values” for all seeds and compare the revised values with Monte Carlo and consensus values. Methods: The relative absorbed-dose energy dependence, f rel , for TLDs and the phantom correction, P phant , are calculated for 125 I and 103 Pd seeds using the EGSnrc BrachyDose and DOSXYZnrc codes. The original energy dependence and phantom corrections applied to DRC measurements are replaced by calculated (f rel ) −1 and P phant values for 24 different seed models. By comparing the modified measured DRCs to the MC values, an appropriate relative intrinsic energy dependence, k bq rel , is determined. The new P phant values and relative absorbed-dose sensitivities, S AD rel , calculated as the product of (f rel ) −1 and (k bq rel ) −1 , are used to individually revise the measured DRCs for comparison with Monte Carlo calculated values and TG-43U1 or TG-43U1S1 consensus values. Results: In general, f rel is sensitive to the energy spectra and models of the brachytherapy seeds. Values may vary up to 8.4% among 125 I and 103 Pd seed models and common TLD shapes. P phant values depend primarily on the isotope used. Deduced (k bq rel ) −1 values are 1.074 ± 0.015 and 1.084 ± 0.026 for 125 I and 103 Pd seeds, respectively. For (1 mm) 3 chips, this implies an overall absorbed-dose sensitivity relative to 60 Co or 6 MV calibrations of 1.51 ± 1% and 1.47 ± 2% for 125 I and 103 Pd seeds, respectively, as opposed to the widely used value of 1.41. Values of P phant calculated here have much lower statistical uncertainties than literature values, but systematic uncertainties from density and composition uncertainties are significant. Using these revised values with the literature’s DRC measurements, the

  6. Electroless Sliver-Plating Process in the Preparation of 103Pd-125I Hybrid Brachytherapy Seed Cores

    Directory of Open Access Journals (Sweden)

    LI Zhong-yong1,2;CHEN Bin-da1;Lv Xiao-zhou1;LU Jin-hui1;CUI Hai-ping1,2

    2014-02-01

    Full Text Available Electroless 103Pd plating and electroless Ag plating and chemical 125I depositing were took place on the surface of carbon rods in turn, which was a reliable method for the preparation of 103Pd-125I hybrid brachytherapy seed cores. 103Pd and 125I were deposited on the same substrate effectively through silver coating as a bridge. The process of electroless Ag plating was a novel and important step in the preparation of 103Pd-125I hybrid seed. In this work, the process of electroless Ag plating was studied using 0.5×3.0 mm carbon rods with palladium coating as substrate, silver-ammino complex as precursor, 110mAg as radioactive tracer, and hydrazine as reductant. The optimum conditions were AgNO3 2g/L,Na2EDTA 40 g/L,NH3•H2O 16.25%,H4N2•H2O 5‰,pH=10,t=60 min,and T=35 ℃. Sliver deposited on each carbon rod was uniform, and sliver-coating was white and smooth.

  7. The effectiveness of 125I seed interstitial brachytherapy for transplantation tumor of human pancreatic carcinoma in nude mice: an experiment in vivo

    International Nuclear Information System (INIS)

    Song Qi; Liu Yu; Wang Zhongmin; Huang Wei; Lu Jian; Chen Kemin

    2010-01-01

    Objective: To discuss the effectiveness and therapeutic mechanism of 125 I interstitial brachytherapy for transplantation tumor of human pancreatic carcinoma in nude mice. Methods: The human pancreatic cell line Sw1990 was subcutaneously injected into the right lower limb partially dorsal area next to the groin of the immunodeficient BABL /c nude mice. The tumor was removed and cut into small pieces after it was formed,then the tumor pieces were inoculated in nude mice. The tumor developed to 8-10 mm in size after six weeks. A total of 16 nude mice with the suitable tumor size were used in this study. The 16 experimental mice were randomly and equally divided into two groups. The mice in study group (n = 8) were implanted with 125 I seeds, while the mice in control group (n = 8) were implanted with ghost seeds. After the implantation both the long and short diameter of the tumors as well as the mouse body weight were measured every 4 days. The tumor weight was measured when the mouse was sacrificed. The paraffin-embedded samples were sent for histopathological examination. Apoptotic cells were checked with terminal deoxynucleotidyl transferase dUTP nick end labeling (TUNEL) method. Expression of proliferating cell nuclear antigen (PCNA) was detected with immuno-histochemical staining. Results: The tumor grew slowly in the study group, but rapidly in the control group. The tumor weight in the study group and the control group was (2.68 ± 0.70)g and (4.68 ± 1.45)g, respectively, the difference between two groups was statistically significant (P = 0.021). The tumor inhibition rate was about 42.66%. No significant difference in body weight of nude mice existed between two groups both before and after the treatment (P > 0.05). Marked tumor necrosis was seen in study group, but no obvious, or only a little, tumor necrosis could be observed in the control group. The apoptotic index checked with the TUENL method in the study group and control group was (23.2 ± 1.9)% and

  8. Bystander effects of exposure to low-dose-rate 125I seeds on human lung cancers cells in vitro

    International Nuclear Information System (INIS)

    Jia Rongfei; Chen Honghong; Yu Lei; Zhao Meijia; Shao Chunlin; Cheng Wenying

    2007-01-01

    The bystander effects induced by continuous low-dose-rate (LDR) 125 I seeds radiation on damage of human lung cancer cells were investigated. Human adenocarcinoma cell line A549 and human small cell lung cancer cell line NCI-H446, which have different sensitivities to high-dose rate (HDR) external irradiation, were exposed directly to 125 I seeds in vitro and co-cultured with unirradiated cells for 24 h. Using cytokinesis-blocking micronucleus method and γ H2AX fluorescence immunoassay, bystander effects induced by 2Gy and 4Gy 125 I seed irradiation on micronucleus formation and DNA double-strand breaks (DSBs) of human lung cancer cells were detected and evaluated. The results showed that irradiation with 125 I seeds can induce medium-mediated bystander effects in A549 cells and NCI-H446 cells, exhibiting that both micronuclei formation and γ H2AX focus formation in bystander cells were increased significantly compared with non-irradiated cells. The extent of DNA damage induced by bystander effects was correlated with accumulated radiation dose and radiosensitive of tumor cells. NCI-H446 cells that were sensitive to HDR γ irradiation were more sensitive to continuous LDR irradiation and bystander effects than A549. However, a comparison between the bystander effects and direct effects elicits the intensity of bystander responses of A549 cells was higher than that of NCI-H446 cells. A dose-related reduction in bystander responses was observed both in A549 cells and NCI-H446 cells, suggesting that the signaling factors involved in the bystander signaling pathways may decrease with the increase of cell damages. (authors)

  9. The implantation of esophageal stent with radioactive 125I particles for advanced esophageal carcinomas: observation of therapeutic results

    International Nuclear Information System (INIS)

    Zhao Peng; Cui Hongkai; Yang Ruimin; Zhang Xizhong

    2011-01-01

    Objective: To investigate the therapeutic effect of the implantation of esophageal stent with radioactive 125 I particles in treating advanced esophageal carcinomas in aged patients. Methods: During the period from Sep. 2009 to Dec. 2010, implantation of esophageal stent was used to treat 43 aged patients with advanced esophageal cancer. Based on the patient's free will, the patients were divided into study group (n=18) receiving stent with 125 I particles and control group (n=25) receiving ordinary stent without 125 I particles. No significant difference in the age, the lesion length, the degree of stenosis and the disease stage existed between the study group and the control group. The technical success rate, the remission rate of dysphagia, the occurrence of complications and the mean survival time were calculated and analyzed. The results were compared between the two groups. Results: The technical success rate was 100% in both groups. The short-term remission rate of dysphagia was also 100% in both groups. The mean survival time in the study group and in the control group was 9.8 months and 4.8 months respectively, the difference between the two groups was statistically significant (P 0.05). Conclusion: This results of study indicate that for the treatment of advanced esophageal carcinomas the implantation of esophageal stent with radioactive 125 I particles can surely and markedly prolong the patient's survival time and relive the symptom of dysphagia. This technique is safe, feasible and effective in clinical practice. The use of the stent with radioactive 125 I particles is superior to the use of the traditional stent in treating patients with advanced esophageal cancer. (authors)

  10. In vivo dosimetry using a linear Mosfet-array dosimeter to determine the urethra dose in 125I permanent prostate implants.

    Science.gov (United States)

    Bloemen-van Gurp, Esther J; Murrer, Lars H P; Haanstra, Björk K C; van Gils, Francis C J M; Dekker, Andre L A J; Mijnheer, Ben J; Lambin, Philippe

    2009-01-01

    In vivo dosimetry during brachytherapy of the prostate with (125)I seeds is challenging because of the high dose gradients and low photon energies involved. We present the results of a study using metal-oxide-semiconductor field-effect transistor (MOSFET) dosimeters to evaluate the dose in the urethra after a permanent prostate implantation procedure. Phantom measurements were made to validate the measurement technique, determine the measurement accuracy, and define action levels for clinical measurements. Patient measurements were performed with a MOSFET array in the urinary catheter immediately after the implantation procedure. A CT scan was performed, and dose values, calculated by the treatment planning system, were compared to in vivo dose values measured with MOSFET dosimeters. Corrections for temperature dependence of the MOSFET array response and photon attenuation in the catheter on the in vivo dose values are necessary. The overall uncertainty in the measurement procedure, determined in a simulation experiment, is 8.0% (1 SD). In vivo dose values were obtained for 17 patients. In the high-dose region (> 100 Gy), calculated and measured dose values agreed within 1.7% +/- 10.7% (1 SD). In the low-dose region outside the prostate (MOSFET detectors are suitable for in vivo dosimetry during (125)I brachytherapy of prostate cancer. An action level of +/- 16% (2 SD) for detection of errors in the implantation procedure is achievable after validation of the detector system and measurement conditions.

  11. The incidence of radioepidermitis and the dose-response relationship in parotid gland cancer patients treated with 125I seed brachytherapy. Incidence of radioepidermitis and the dose-response relationship

    Energy Technology Data Exchange (ETDEWEB)

    Mao, Ming-Hui; Zheng, Lei; Gao, Hong; Zhang, Jie; Liu, Shu-ming; Huang, Ming-wei; Shi, Yan [Peking University School and Hospital of Stomatology, Department of Oral and Maxillofacial Surgery, Beijing (China); Zhang, Jian-Guo [Peking University School and Hospital of Stomatology, Department of Oral and Maxillofacial Surgery, Beijing (China); Fujian Provincial Hospital, Fujian (China)

    2014-09-09

    We studied the incidence and dose-response relationship of radioepidermitis in parotid gland carcinoma patients treated with [{sup 125}I] seed brachytherapy in the hopes of designing an optimized pre-implant treatment plan that would reduce the incidence and severity of radioepidermitis in patients receiving this therapy. Between January 2007 and May 2010, 100 parotid gland cancer patients were treated postoperatively with [{sup 125}I] seed brachytherapy. The matched peripheral dose (MPD) was 80-140 Gy, and [{sup 125}I] seed activity was 0.7-0.8 mCi. The mean dose delivered to the skin was calculated in the post-implant CT on day 0 following implantation. Grades of acute and late dermatitis were evaluated at 2, 6, 12, and 18 months post-implantation. Most patients experienced grade 0-2 acute and late skin side effects (86 and 97 %, respectively), though a small subset developed severe complications. Most grade 1-3 effects resolved within 6 months of implantation, though some grade 1-3 effects and all grade 4 effects remained unchanged throughout the 18-month follow-up period. Grade 3 and 4 effects were most prominent (75 and 25 %, respectively) with doses of 110-140 Gy; doses higher than 140 Gy produced only grade 4 effects. [{sup 125}I] seed brachytherapy produced acceptable levels of acute and late radioepidermitis with a good clinical outcome. A mean dose under 100 Gy delivered to the skin was safe, though doses of 110-140 Gy should be given with caution and extra monitoring; doses greater than 140 Gy are dangerous and likely to produce grade 4-5 effects. (orig.) [German] Wir untersuchten die Inzidenz und die Dosis-Wirkung-Beziehung bei Patienten mit Ohrspeicheldruesenkrebs, die mit [{sup 125}I]-Seed-Brachytherapie behandelt wurden, in der Hoffnung, eine optimierte praeimplantologische Behandlung zu entwickeln, welche die Inzidenz und Schwere der Radioepidermitis bei Patienten, die diese Therapie erhalten haben, reduziert. Zwischen Januar 2007 und Mai 2010

  12. The direct biologic effects of radioactive 125I seeds on pancreatic cancer cells PANC-1, at continuous low-dose rates.

    Science.gov (United States)

    Wang, Jidong; Wang, Junjie; Liao, Anyan; Zhuang, Hongqing; Zhao, Yong

    2009-08-01

    The relative biologic effectiveness of model 6711 125I seeds (Ningbo Junan Pharmaceutical Technology Company,Ningbo, China) and their effects on growth, cell cycle, and apoptosis in human pancreatic cancer cell line PANC-1 were examined in the present study. PANC-1 cells were exposed to the absorbed doses of 1, 2, 4, 6, 8, and 10 Gyeither with 125I seeds (initial dose rate, 2.59 cGy=h) or with 60Co g-ray irradiation (dose rate, 221 cGy=min),respectively. Significantly greater numbers of apoptotic PANC-1 cells were detected following the continuouslow-dose-rate (CLDR) irradiation of 125I seeds, compared with cells irradiated with identical doses of 60Co g-ray. The D(0) for 60Co g-ray and 125I seed irradiation were 2.30 and 1.66, respectively. The survival fraction after 125Iseed irradiation was significantly lower than that of 60Co g-ray, with a relative biologic effectiveness of 1.39.PANC-1 cells were dose dependently arrested in the S-phase by 60Co g-rays and in the G2=M phase by 125I seeds,24 hour after irradiation. CLDR irradiation by 125I seeds was more effective in inducing cell apoptosis in PANC-1cells than acute high-dose-rate 60Co g irradiation. Interestingly, CLDR irradiation by 125I seeds can cause PANC-1cell-cycle arrest at the G2=M phase and induce apoptosis, which may be an important mechanism underlying 125Iseed-induced PANC-1 cell inhibition.

  13. Prostatic edema in 125I permanent prostate implants: Dynamical dosimetry taking volume changes into account

    International Nuclear Information System (INIS)

    Leclerc, Ghyslain; Lavallee, Marie-Claude; Roy, Rene; Vigneault, Eric; Beaulieu, Luc

    2006-01-01

    The purpose of this study is to determine the impact of edema on the dose delivered to the target volume. An evaluation of the edema characteristics was first made, and then a dynamical dosimetry algorithm was developed and used to compare its results to a standard clinical (static) dosimetry. Source positions and prostate contours extracted from 66 clinical cases on images taken at different points in time (planning, implant day, post-implant evaluation) were used, via the mean interseed distance, to characterize edema [initial increase (Δr 0 ), half-life (τ)]. An algorithm was developed to take into account the edema by summing a time series of dose-volume histograms (DVHs) with a weight based on the fraction of the dose delivered during the time interval considered. The algorithm was then used to evaluate the impact of edema on the dosimetry of permanent implants by comparing its results to those of a standard clinical dosimetry. The volumetric study yielded results as follows: the initial prostate volume increase was found to be 1.58 (ranging from 1.15 to 2.48) and the edema half-life, approximately 30 days (range: 3 to 170 days). The dosimetric differences in D 90 observed between the dynamic dosimetry and the clinical one for a single case were up to 15 Gy and depended on the edema half-life and the initial volume increase. The average edema half-life, 30 days, is about 3 times longer than the previously reported 9 days. Dosimetric differences up to 10% of the prescription dose are observed, which can lead to differences in the quality assertion of an implant. The study of individual patient edema resorption with time might be necessary to extract meaningful clinical correlation or biological parameters in permanent implants

  14. Anti-tumor effects of 125I radioactive particles implantation on transplantated tumor model of human breast cancer cells in nude mice

    International Nuclear Information System (INIS)

    Xiao Zhongdi; Liang Chunlin; Zhang Guoli; Jing Yue; Zhang Yucheng; Gai Baodong

    2011-01-01

    Objective: To study the anti-tumor effects of 125 I radioactive particles implantation on transplantated tumor model of human breast cancer cells in nude mice and clarify their anti-tumor mechanisms. Methods 120 nude mice transplantated with human breast cancer cells MCF-7 were randomly divided into 3 groups (n=40): 125 I radioactive particles implanted group, non-radioactive particles implanted group and non-particles implanted group. The articles were implanted into mice according to Pairs system principle. The expressions of Fas mRNA and protein and the activaties of caspase-3 and caspase-8 enzyme were detected by RT-PCR and Western blotting. The changes of cell cycle were detected by flow cytometry. Results: Compared with non-radioactive particles implanted group and non-particles implanted group, the size of cancer tissues in 125 I radioactive particles implanted group was reduced significantly (P 0 /G 1 phase was significantly increased (P 125 I radioactive particles into transplantated tumor model of human breast cancer cells can kill tumor cells, inhibit the growth cycle of tumor cells and induce the apoptosis of tumor cells in nude mice. (authors)

  15. Bystander Effects Induced by Continuous Low-Dose-Rate 125I Seeds Potentiate the Killing Action of Irradiation on Human Lung Cancer Cells In Vitro

    International Nuclear Information System (INIS)

    Chen, H.H.; Jia, R.F.; Yu, L.; Zhao, M.J.; Shao, C.L.; Cheng, W.Y.

    2008-01-01

    Purpose: To investigate bystander effects of low-dose-rate (LDR) 125 I seed irradiation on human lung cancer cells in vitro. Methods and Materials: A549 and NCI-H446 cell lines of differing radiosensitivity were directly exposed to LDR 125 I seeds irradiation for 2 or 4 Gy and then cocultured with nonirradiated cells for 24 hours. Induction of micronucleus (MN), γH2AX foci, and apoptosis were assayed. Results: After 2 and 4 Gy irradiation, micronucleus formation rate (MFR) and apoptotic rate of A549 and NCI-H446 cells were increased, and the MFR and apoptotic rate of NCI-H446 cells was 2.1-2.8 times higher than that of A549 cells. After coculturing nonirradiated bystander cells with 125 I seed irradiated cells for 24 hours, MFR and the mean number of γH2AX foci/cells of bystander A549 and NCI-H446 cells were similar and significantly higher than those of control (p 125 I seeds could induce bystander effects, which potentiate the killing action on tumor cells and compensate for the influence of nonuniform distribution of radiation dosage on therapeutic outcomes

  16. Cooperation of Ad-hING4 and 125I seed in tumor-suppression on human pancreatic cancer xenograft in nude mice

    International Nuclear Information System (INIS)

    Zhai Hongyan; Fa Yihua; Su Chenghai; Yang Jicheng; Sheng Weihua; Xie Yufeng

    2009-01-01

    This work is to investigate the combined tumor-suppression effect of Adenovirus-mediated human ING4 (Ad-hING4) and 125 I seed on human pancreatic cancer xenograft and the possible mechanisms. Ad-hING4 recombinant adenovirus vector was transected into QBI-293A cells and high titre adenovirus was obtained. Subcutaneous tumor models were established with 25 nude mice with human pancreatic cancer cell line PANC-1. They were randomly divided into 5 groups: PBS control group, Ad carrier group, 125 I seed brachytherapy group, Ad-hING4 gene treatment group, combined 125 I seed and Ad-hING4 group. The tumor volumes were measured every 5 days after treatment, and were sacrificed on the 20th day. The tumors were measured and weighed to determine the ratio of tumor-suppression and Jin-Shi q value. Morphological changes of tumor cells,the tissue injury and apoptotic index AI were examined on pathological sections. MVD, Survivin and Caspase3 were tested in immunohistochemistry. The results show that the tumor-suppressive ratio of the 125 I seed group, Ad-hING4 group, combined treatment group were,respectively, 34.19%(P 0.05). It can be concluded that 125 I seed and Ad-hING4 inhibit the growth of PANC-1 pancreatic cancer on nude mice significantly. These indicate a synergy of the combined treatments in tumor-suppression and Ad-hING4 is a promising novel radiosensitizer. The mechanisms of tumor-suppressive may be multi-pathways such as down-regulation the expression of Survivin and up-regulation the expression of Caspase3 to induce apoptosis and inhibit angiogenesis. (authors)

  17. Postoperative [{sup 125}I] seed brachytherapy in the treatment of acinic cell carcinoma of the parotid gland. With associated risk factors

    Energy Technology Data Exchange (ETDEWEB)

    Mao, Ming-hui; Zhang, Jian-Guo; Zhang, Jie; Zheng, Lei; Liu, Shu-ming; Huang, Ming-wei; Shi, Yan [Peking Univ. School and Hospital of Stomatology, Beijing (China). Dept. of Oral and Maxillofacial Surgery

    2014-11-15

    This retrospective study was undertaken to analyze data from patients receiving iodine-125 ([{sup 125}I]) seed brachytherapy postoperatively for the treatment of acinic cell carcinoma (ACC) of the parotid gland along with the following risk factors: residual tumor, recurrent tumor, facial nerve invasion, positive resection margins, advanced tumor stage, or tumor spillage. Twenty-nine patients with ACC (17 females, 12 males; age range, 13-73 years; median age, 37.3 years) were included. Median follow-up was 58.2 months (range, 14-122 months). Patients received [{sup 125}I] seed brachytherapy (median actuarial D90, 177 Gy) 3-41 days (median, 14 days) following surgery. Radioactivity was 18.5-33.3 MBq per seed, and the prescription dose was 80-120 Gy. The 3-, 5-, and 10-year rates of local control were 93.1, 88.7, and 88.7 %, respectively; overall survival was 96.6, 92, and 92 %; disease-free survival was 93.1, 88.4, and 88.4 %; and freedom from distant metastasis was 96.6, 91.2, and 91.2 %. Lymph node metastases were absent in all patients, although two patients died with distant metastases. Facial nerve recovery was quick, and no severe radiotherapy-related complications were noted. Recurrence history, local recurrence, and distant metastasis significantly affected overall survival. Postoperative [{sup 125}I] seed brachytherapy is effective in treating ACC and has minor complications. Patients with a history of recurrence showed poor prognosis and were more likely to experience disease recurrence and develop metastases. (orig.) [German] Diese retrospektive Studie wurde durchgefuehrt, um die Daten von Patienten zu analysieren, die postoperativ eine Seed-Brachytherapie mit Iod-125 ([{sup 125}I]) zur Behandlung von Azinuszellkarzinomen der Ohrspeicheldruese mit begleitenden Risikofaktoren, wie Residualtumor, Rezidivtumor, Invasion in den N. facialis, positive (= nicht tumorfreie) Resektionsraender, fortgeschrittenes Tumorstadium oder lokale Verbreitung von Tumorzellen

  18. Monte Carlo simulation of the dose distribution around the 125I model 6711 seed as function of radius of the silver cylinder using the Penelope code

    International Nuclear Information System (INIS)

    Nerio, U.; Chica, L.; Paul, A.

    2004-01-01

    The Monte Carlo method is applied to find the dose rates distribution in tissue around 125 I seeds model 6711 as a function of the silver cylinder radius, R sc (0.017, 0.021, 0.025, 0.029 and 0.033) cm are used as radius values. It is found here that the dose rate at any point within the tissue decreases as R sc increases. The relative difference of dose rate that produced by the standard R sc seed, is less than 5%, for seeds with Rsc between 0.017 and 0.033 cm. (author)

  19. A Novel Self-Expandable, Radioactive Airway Stent Loaded with 125I Seeds: A Feasibility and Safety Study in Healthy Beagle Dog.

    Science.gov (United States)

    Wang, Yong; Guo, Jin-He; Zhu, Guang-Yu; Zhu, Hai-Dong; Chen, Li; Lu, Jian; Wang, Chao; Teng, Gao-Jun

    2017-07-01

    Airway stent placement is an effective treatment for the immediate palliation of malignant airway obstruction. However, restenosis caused by tumor ingrowth and/or overgrowth after stenting is common. The purpose of this study was to investigate the feasibility and safety of a novel self-expandable stent loaded with 125 I seeds in healthy beagle dog. Under fluoroscopic guidance, forty-eight self-expandable airway stents loaded with 125 I seeds were perorally placed in the main trachea of 48 healthy beagle dogs, who were randomly divided into four groups (Group A: 0.3 mCi; Group B: 0.6 mCi; Group C: 0.9 mCi; Control group: 0 mCi). The estimated radiation dose was calculated using the isotropic point source approximation. Radiological follow-up examinations and histopathological examinations of stented tracheal segments and their adjacent organs and tissues were performed at 2, 4, 8, and 16 weeks following the stenting. All stents were successfully deployed in the targeted tracheal segment in the beagle dogs without procedure-related complications. Tracheal stenosis became severe gradually in all the four groups, which was not associated with the radioactivity of 125 I seeds (p > 0.05). The tracheal injury scores increased along with the higher dose of radioactive seeds which reached peak at 8 weeks and then turned back slightly at 16 weeks. The adjacent tissue did not show pathohistological changes under microscope, while mild and reversible ultrastructure changes were showed under electronic microscope. This study demonstrates that it is feasible and safe to insert this novel self-expandable airway stent loaded with 125 I seeds in healthy beagle dog.

  20. The Effect of Scattering from Leg Region on Organ Doses in Prostate Brachytherapy for 103Pd, 125I and 131Cs Seeds

    Directory of Open Access Journals (Sweden)

    Seyed Milad Vahabi

    2016-09-01

    Full Text Available Introduction Dose calculation of tumor and surrounding tissues is essential during prostate brachytherapy. Three radioisotopes, namely, 125I, 103Pd, and 131Cs, are extensively used in this method. In this study, we aimed to calculate the received doses by the prostate and critical organs using the aforementioned radioactive seeds and to investigate the effect of scattering contribution for the legs on dose calculations. Materials and Methods The doses to organs of interest were calculated using MCNPX code and ORNL (Oak Ridge National Laboratory phantom. Results Doses to the prostate as a source of radiation for 125I, 103Pd, and 131Cs were approximately 108.9, 97.7, and 81.5 Gy, respectively. Bladder, sigmoid colon, and testes received higher doses than other organs due to proximity to the prostate. Differences between the doses when tallying with the legs intact and with the legs voided were significant for testes, sigmoid colon contents, and sigmoid colon wall because of their proximity to the prostate. There was also a good consistency between our results and the data published by Montefiore Medical Center and Albert Einstein College of Medicine for the prostate. Conclusion Scattering from leg region had a significant effect on doses to testes, sigmoid colon contents, and sigmoid colon wall in the pelvic region, and prostate and the other organs were unaffected. Brachytherapy treatment plans using 131Cs seeds allow for better sparing of critical tissues, with a comparable number of, or fewer, seeds required, compared to 125I seeds.

  1. Dosimetric studies, spectrometric, radiographic, metallographic of a new argentinean seed of {sup 125} I used in brachytherapy; Estudios dosimetricos, espectrometricos, radiograficos, metalograficos de una nueva semilla argentina de {sup 125}I empleada en braquiterapia

    Energy Technology Data Exchange (ETDEWEB)

    Pirchio, R.; Saravi, M.; Banchik, D.; Munoz, C. [CNEA, Pbro. J. Gonzalez y Aragon No. 15 (B1802AYA), Ezeiza, Buenos Aires (Argentina)]. e-mail: pirchio@cae.cnea.gov.ar

    2006-07-01

    A new source of {sup 125} I model Braquibac{sup TM} has been developed in Argentina for applications in interstitial brachytherapy. The AAPM Task Group 43 (TG-43) recommends that dosimetric characteristics of new sources of brachytherapy of Iodine-125 have been theoretically and experimentally determined before its clinical use. The objectives outlined in this work were the study of the design of the new seed, the calculation of dosimetric parameters and the photons spectra analysis. Its were carried out radiographic and metallographic studies to determine the physical characteristics of the source. For the realization of the dosimetric calculations it was used the Monte Carlo code MCNP5. Values of the radial dose function, g(r), of the constant of dose rate, {lambda}, of the function of anisotropy of two dimensions, F(r, {theta}), of the factor and constant of anisotropy its were obtained simulating the source in water according to the recommended methodology in TG-43. The constant of dose rate is similar to 0,880 {+-} 0,080 c Gy h{sup -1} U{sup -1}. The kerma in air rate of reference, S{sub K}, was calculated as 1,036 c Gy cm{sup 2}h{sup -1} mCi{sup -1} simulating the seed in dry air. Its were carried out spectrometric studies using a semiconductor planar detector of HPGe (high purity germanium). Photons spectra showed characteristic x-rays of {sup 125} I with energies of 27,20 keV, 27,47 keV, 31 keV and 31,70 keV gamma photons of 35,5 keV, and x-ray fluorescent coming from the silver nucleus of 22,10 keV, 24,94 keV and 25,45 keV. The angular dependence of the intensity of photons around the seed and in air it was analyzed with the planar detector. This was carried out to study the anisotropy in the photons flow due to variation in the thickness of the titanium wall and of the welding, movements of the silver tube inside the source and deposition of the radioactive material on the silver tube. (Author)

  2. Influence of sequential 125I particle chain implantation and transcatheter arterial chemoembolization on tumor cell killing effect in patients with liver cancer

    Directory of Open Access Journals (Sweden)

    Wei Dai

    2017-07-01

    Full Text Available Objective: To study the influence of sequential 125I particle chain implantation and transcatheter arterial chemoembolization (TACE on tumor cell killing effect in patients with liver cancer. Methods: A total of 82 cases of patients with advanced liver cancer who were treated in our hospital between September 2014 and December 2016 were collected, reviewed and then divided into the control group (n=45 who received TACE alone and the observation group (n=37 who received sequential 125I particle chain implantation and TACE. Serum levels of tumor markers, angiogenesis indexes and apoptosis molecules before and after treatments were compared between two groups of patients. Results: Before treatment, differences in serum levels of tumor markers, angiogenesis indexes and apoptosis molecules were not statistically significant between two groups of patients. After treatment, serum tumor markers AFP, CA199, CA153 and Ferritin levels in observation group were lower than those in control group; serum angiogenesis indexes VEGF, PEDF, ES and bFGF contents were lower than those in control group; serum apoptosis molecules p53 and Fas contents were higher than those in control group. Conclusion: Sequential 125I particle chain implantation and TACE treatment of advanced liver cancer can effectively reduce tumor malignancy and promote tumor apoptosis.

  3. SU-F-T-46: The Effect of Inter-Seed Attenuation and Tissue Composition in Prostate 125I Brachytherapy Dose Calculations

    Energy Technology Data Exchange (ETDEWEB)

    Tamura, K; Araki, F; Ohno, T [Kumamoto University, Kumamoto, Kumamoto (Japan)

    2016-06-15

    Purpose: To investigate the difference of dose distributions with/without the effect of inter-seed attenuation and tissue compositions in prostate {sup 125}I brachytherapy dose calculations, using Monte Carlo simulations of Particle and Heavy Ion Transport code System (PHITS). Methods: The dose distributions in {sup 125}I prostate brachytherapy were calculated using PHITS for non-simultaneous and simultaneous alignments of STM1251 sources in water or prostate phantom for six patients. The PHITS input file was created from DICOM-RT file which includes source coordinates and structures for clinical target volume (CTV) and organs at risk (OARs) of urethra and rectum, using in-house Matlab software. Photon and electron cutoff energies were set to 1 keV and 100 MeV, respectively. The dose distributions were calculated with the kerma approximation and the voxel size of 1 × 1 × 1 mm{sup 3}. The number of incident photon was set to be the statistical uncertainty (1σ) of less than 1%. The effect of inter-seed attenuation and prostate tissue compositions was evaluated from dose volume histograms (DVHs) for each structure, by comparing to results of the AAPM TG-43 dose calculation (without the effect of inter-seed attenuation and prostate tissue compositions). Results: The dose reduction due to the inter-seed attenuation by source capsules was approximately 2% for CTV and OARs compared to those of TG-43. In additions, by considering prostate tissue composition, the D{sub 90} and V{sub 100} of CTV reduced by 6% and 1%, respectively. Conclusion: It needs to consider the dose reduction due to the inter-seed attenuation and tissue composition in prostate {sup 125}I brachytherapy dose calculations.

  4. Comparison of Dosimetric and Biologic Effective Dose Parameters for Prostate and Urethra Using 131Cs and 125I for Prostate Permanent Implant Brachytherapy

    International Nuclear Information System (INIS)

    Sahgal, Arjun; Jabbari, Siavash; Chen, Josephine; Pickett, Barbie; Roach, Mack; Weinberg, Vivian; Hsu, I-C.; Pouliot, Jean

    2008-01-01

    Purpose: To compare the urethral and prostate absolute and biologic effective doses (BEDs) for 131 Cs and 125 I prostate permanent implant brachytherapy (PPI). Methods and Materials: Eight previously implanted manually planned 125 I PPI patients were replanned manually with 131 Cs, and re-planned using Inverse Planning Simulated Annealing. 131 Cs activity and the prescribed dose (115 Gy) were determined from that recommended by IsoRay. The BED was calculated for the prostate and urethra using an α/β ratio of 2 and was also calculated for the prostate using an α/β ratio of 6 and a urethral α/β ratio of 2. The primary endpoints of this study were the prostate D 90 BED (pD 90 BED) and urethral D 30 BED normalized to the maximal potential prostate D 90 BED (nuD 30 BED). Results: The manual plan comparison (α/β = 2) yielded no significant difference in the prostate D 90 BED (median, 192 Gy 2 for both isotopes). No significant difference was observed for the nuD 30 BED (median, 199 Gy 2 and 202 Gy 2 for 125 I and 131 Cs, respectively). For the inverse planning simulated annealing plan comparisons (α/β 2), the prostate D 90 BED was significantly lower with 131 Cs than with 125 I (median, 177 Gy 2 vs. 187 Gy 2 , respectively; p = 0.01). However, the nuD 30 BED was significantly greater with 131 Cs than with 125 I (median, 192 Gy 2 vs. 189 Gy 2 , respectively; p = 0.01). Both the manual and the inverse planning simulated annealing plans resulted in a significantly lower prostate D 90 BED (p = 0.01) and significantly greater nuD 30 BED for 131 Cs (p = 0.01), compared with 125 I, when the prostate α/β ratio was 6 and the urethral α/β ratio was 2. Conclusion: This report highlights the controversy in comparing the dose to both the prostate and the organs at risk with different radionuclides

  5. Evaluation of material heterogeneity dosimetric effects using radiochromic film for COMS eye plaques loaded with 125I seeds (model I25.S16)

    International Nuclear Information System (INIS)

    Acar, Hilal; Chiu-Tsao, Sou-Tung; Özbay, İsmail; Kemikler, Gönül; Tuncer, Samuray

    2013-01-01

    Purpose: (1) To measure absolute dose distributions in eye phantom for COMS eye plaques with 125 I seeds (model I25.S16) using radiochromic EBT film dosimetry. (2) To determine the dose correction function for calculations involving the TG-43 formalism to account for the presence of the COMS eye plaque using Monte Carlo (MC) method specific to this seed model. (3) To test the heterogeneous dose calculation accuracy of the new version of Plaque Simulator (v5.3.9) against the EBT film data for this seed model. Methods: Using EBT film, absolute doses were measured for 125 I seeds (model I25.S16) in COMS eye plaques (1) along the plaque's central axis for (a) uniformly loaded plaques (14–20 mm in diameter) and (b) a 20 mm plaque with single seed, and (2) in off-axis direction at depths of 5 and 12 mm for all four plaque sizes. The EBT film calibration was performed at 125 I photon energy. MC calculations using MCNP5 code for a single seed at the center of a 20 mm plaque in homogeneous water and polystyrene medium were performed. The heterogeneity dose correction function was determined from the MC calculations. These function values at various depths were entered into PS software (v5.3.9) to calculate the heterogeneous dose distributions for the uniformly loaded plaques (of all four sizes). The dose distributions with homogeneous water assumptions were also calculated using PS for comparison. The EBT film measured absolute dose rate values (film) were compared with those calculated using PS with homogeneous assumption (PS Homo) and heterogeneity correction (PS Hetero). The values of dose ratio (film/PS Homo) and (film/PS Hetero) were obtained. Results: The central axis depth dose rate values for a single seed in 20 mm plaque measured using EBT film and calculated with MCNP5 code (both in ploystyrene phantom) were compared, and agreement within 9% was found. The dose ratio (film/PS Homo) values were substantially lower than unity (mostly between 0.8 and 0.9) for all

  6. High-resolution 3D dose distribution measured for two low-energy x-ray brachytherapy seeds: 125I and 103Pd

    International Nuclear Information System (INIS)

    Massillon-JL, G.; Minniti, R.; Mitch, M.G.; Soares, C.G.; Hearn, R.A.

    2011-01-01

    In this work, we have investigated the 3D absorbed dose distribution around 125 I and 103 Pd low-energy photon brachytherapy seeds using a high-spatial-resolution gel scanning system to address the current difficulty in measuring absorbed dose at close distances to these sources as a consequence of high dose rate gradient. A new version of BANG-gel coupled with a small format laser CT scanner has been used. Measurements were performed with 100 μm resolution in all dimensions. In particular, radial dose function and absorbed dose rate in the plane parallel to the sources longitudinal-axis were derived at radial distances smaller than or equal to 1 cm. In addition, the energy dependence was evaluated, finding that, within measurement uncertainties, the gel response is independent of the energy for energy photon values between 20 keV and 1250 keV. We have observed that at distances larger than 1.4 mm from the source, the delivered dose is similar to predictions from published Monte Carlo calculations (MC) for the 125 I seed. For distances between 1 mm and 3 mm, differences in magnitude and shape are significant for the 103 Pd seed, where an enhancement is observed. In the enhancement region, a difference of up to 70% in the radial dose function was obtained. Such observation suggests a contribution from other radionuclides emitting beta-particles or electrons, and not considered by MC. To understand the effect, spectrometry measurements were performed. A small contribution of 102 Rh/ 102m Rh radionuclide relative to 103 Pd was observed and its importance on the absorbed dose measured at close distances to the seed is time dependent and consequently, avoids reproducible measurements. Finally, the results obtained in this work underscore the importance of using high-spatial-resolution and water-equivalent detectors for measuring absorbed dose in low-energy photon radiation fields.

  7. Results of a dummy run of postimplant dosimetry between multi-institutional centers in prostate brachytherapy with 125I seeds

    International Nuclear Information System (INIS)

    Aoki, Manabu; Yorozu, Atsunori; Dokiya, Takushi

    2009-01-01

    The purpose of this study was to determine the reproducibility and precision of postimplant dosimetry following 125 I prostate brachytherapy (PB) and to evaluate the effects of learning and experience in CT-based postimplant dosimetry. One-month postimplant CT data from two patients who underwent PB alone or combined therapy (PB+external beam radiation therapy (EBRT)) were sent to 28 institutions for postimplant dosimetry and analyzed in 2006 (study 1). Similarly, 1-month postimplant CT data from two other patients were also analyzed in 2008 (study 2; 23 institutions). For both modalities in studies 1 and 2, the variance of the difference between CT-based D90 at each institution and CT/MRI fusion-based D90 was estimated. In monotherapy, F test and Mann-Whitney U test revealed no significant difference in the variance in studies 1 and 2 (P=0.72, 0.46). In combined therapy, the variance significantly converged in study 2 compared with study 1 (P<0.05). Even in the two studies, however, the difference between the median CT-based D90 and fusion-based D90 was at least 20-30 Gy. Marked interobserver variability was seen in the prostate volume and D90 with CT alone. The precision of postimplant dosimetry based on CT alone was revealed to be limited. (author)

  8. Placement of 125I implants with the da Vinci robotic system after video-assisted thoracoscopic wedge resection: A feasibility study

    International Nuclear Information System (INIS)

    Pisch, Julianna; Belsley, Scott J.; Ashton, Robert; Wang Lin; Woode, Rudolph; Connery, Cliff

    2004-01-01

    Purpose: To evaluate the feasibility of using the da Vinci robotic system for radioactive seed placement in the wedge resection margin of pigs' lungs. Methods and materials: Video-assisted thoracoscopic wedge resection was performed in the upper and lower lobes in pigs. Dummy 125 I seeds embedded in absorbable sutures were sewn into the resection margin with the aid of the da Vinci robotic system without complications. In the 'loop technique,' the seeds were placed in a cylindrical pattern; in the 'longitudinal,' they were above and lateral to the resection margin. Orthogonal radiographs were taken in the operating room. For dose calculation, Variseed 66.7 (Build 11312) software was used. Results: With looping seed placement, in the coronal view, the dose at 1 cm from the source was 97.0 Gy; in the lateral view it was 107.3 Gy. For longitudinal seed placement, the numbers were 89.5 Gy and 70.0 Gy, respectively. Conclusion: Robotic technology allows direct placement of radioactive seeds into the resection margin by endoscopic surgery. It overcomes the technical difficulties of manipulating in the narrow chest cavity. With the advent of robotic technology, new options in the treatment of lung cancer, as well as other malignant tumors, will become available

  9. Role of TPS in 125I brachytherapy for orbital tumors

    International Nuclear Information System (INIS)

    Ren Ling; Dai Haojie; Li Quan

    2012-01-01

    Objective: To investigate the role of TPS in 125 I brachytherapy for orbital tumors. Methods: Sixty-six patients with orbital tumor treated with 125 I seeds from 2005 to 2009 were retrospectively analyzed. Forty-three patients were treated using TPS guided brachytherapy and the prescribed dose was 140 Gy. Other 23 patients were treated without TPS but simply implanted with 125 I seeds at 1 cm intervals in parallel with each other intraoperatively. CT and TPS quality verification were performed postoperatively in all patients. Also, CT and (or) MRI examination were performed at 3, 6, 12 and 24 months after brachytherapy for follow-up. χ 2 test and Kaplan-Meier survival analysis with log-rank significance test were used with SPSS 17.0. Results: A total of 1070 125 I seeds were implanted in 66 cases, on average, (16.2 ± 7.3) seeds for each patient. The satisfaction rates of postoperative quality verification in patients with and without TPS pre-plans were 79.07% (34/43) and 43.48% (10/23) respectively (χ 2 =8.542, P=0.003). Ten patients were lost in follow-up. Local recurrence rates in patients with favorable postoperative quality verification were 0 (0/37) in 3 months, 6.25% (2/32) in 6 months, 13.64% (3/22) in 12 months and 3/9 in 24 months respectively, which were significantly different from those (5.26% (1/19), 16.67% (3/18), 30.77% (4/13), 6/6) in the patients with inferior postoperative quality verification (χ 2 =9.017, P=0.0003). Conclusions: TPS plays an important role in 125 I brachytherapy for orbital tumors. Also, postoperative quality verification by TPS may help predict the local recurrence after brachytherapy. (authors)

  10. Effects of radioactive 125I seeds on A549 cell line and human embryonic lung diploid cell line 2BS cultivated in vitro and assessment of its clinical safety dose

    International Nuclear Information System (INIS)

    Bian Wenchao; Qi Liangchen

    2012-01-01

    Objective: To observe the cell count changes of A549 cell line and human embryonic lung diploid cell line 2BS after irradiated by 125 I seeds with different doses, and to study the growth inhibition of 125 I on this two kinds of cell lines, and to determine its clinical safety dose in treatment of non-small cell lung. Methods: 125 I seeds with different doses (low dose: 0.2 mCi, mediate dose: 0.4 mCi, high dose: 0.8 mCi) were chosen and put into A549 cells and human embryonic lung diploid cell line 2BS in vitro, the cells on the 2nd, 4th, 6th and 8th days after irradiation were collected, the alive cells were counted by cells dyeing experiments, then the growth curves were drawn, and the IC 50 of the radioactive 125 I seeds to both two cell lines were calculated. Results: Compared with blank and control groups, the cell proliferation trend of A549 cells in low dose group was not significantly influenced (P>0.05), but the growth of A549 cells in mediate and high dose groups were inhibited in a time-dependent manner, there were significant differences (P<0.05), the most obvious change was on the 6th day. The IC 50 of the radioactive 125 I seeds to A549 cells was about .04 mCi. While the growth inhibition of 125 I 2BS had no statistically significant differences between various dose groups (P>0.05), and the IC 50 of the radioactive 125 I seeds to 2BS cell line was about 1.65 mCi. Conclusion: 0.4 mCi of radioactive 125 I seeds has already had the obvious damage effect on A549 cell, 0.8 mCi of radioactive 125 I seeds has the stronger effect. The IC 50 of the radioactive 125 I seeds to 2BS cells is about 1.65 mCi, so the clinical safety dosage is 0.4-0.8 mCi. (authors)

  11. Monte Carlo calculation of dosimetric parameters of a {sup 125}I brachytherapy seed encapsulation with biocompatible polymer and a ceramic matrix as radiographic marker

    Energy Technology Data Exchange (ETDEWEB)

    Reis, Lucas P.; Santos, Adriano M.; Grynberg, Suely E., E-mail: lpr@cdtn.b [Centro de Desenvolvimento da Tecnologia Nuclear (CDTN/CNEN-MG), Belo Horizonte, MG (Brazil). Lab. de Dosimetria e Simulacao Computacional; Facure, Alessandro, E-mail: facure@cnen.gov.b [Comissao Nacional de Energia Nuclear (CNEN), Rio de Janeiro, RJ (Brazil)

    2011-07-01

    For prostate cancer treatments, there is an increasing interest in the permanent radioactive seeds implant technique. Currently, in Brazil, the seeds are imported at high prices, which prohibit their use in public hospitals. One of the seed models that have been developed at CDTN has a ceramic matrix as a radioisotope carrier and a radiographic marker; the seed is encapsulated with biocompatible polymer. In this work, Monte Carlo simulations were performed in order to assess the dose distributions generated by the prototype seed model. The obtained data was assessed as described in the TG-43U1 report by the AAPM. The dosimetric parameters dose rate constant, {Lambda}, radial dose function, g{sub L}(r), and anisotropy function, F(r,{theta}), were derived from simulations using the MCNP5 code. The function g(r) shows that the seed has a lower decrease in dose rate on its transverse axis when compared to the 6711 model (one of the most used seeds in permanent prostate implants). F(r,{theta}) shows that CDTN's seed anisotropy curves are smoother than the 6711 model curves for {theta}{<=}20 deg and 0.25{<=}r{<=}1 cm. As well, the {Lambda} value is 15% lower than the {Lambda} value of 6711. The results show that CDTN's seed model can deposit a more isotropic dose. Because of the model's characteristics, the seeds can be impregnated with iodine of lower specific activity which would help reducing costs. (author)

  12. Monte Carlo simulation of the dose distribution around the {sup 125}I model 6711 seed as function of radius of the silver cylinder using the Penelope code; Simulacion por el Metodo de Monte Carlo de la distribucion de dosis alrededor de la semilla de {sup 125}I modelo 6711 en funcion del radio del cilindro de plata usando el codigo Penelope

    Energy Technology Data Exchange (ETDEWEB)

    Nerio, U. [Universidad de Cordoba, Monteria (Colombia); Instituto Nacional de Cancerologia, Bogota (Colombia); Chica, L. [Universidad Nacional de Colombia, Bogota (Colombia); Paul, A. [Universite de la Mediterranee, Marseille (France)

    2004-07-01

    The Monte Carlo method is applied to find the dose rates distribution in tissue around {sup 125} I seeds model 6711 as a function of the silver cylinder radius, R{sub sc} (0.017, 0.021, 0.025, 0.029 and 0.033) cm are used as radius values. It is found here that the dose rate at any point within the tissue decreases as R{sub sc} increases. The relative difference of dose rate that produced by the standard R{sub sc} seed, is less than 5%, for seeds with Rsc between 0.017 and 0.033 cm. (author)

  13. Biologically effective dose (BED) for interstitial seed implants containing a mixture of radionuclides with different half-lives

    International Nuclear Information System (INIS)

    Chen Zhe; Nath, Ravinder

    2003-01-01

    Purpose: To develop a tool for evaluating interstitial seed implants that contain a mixture of radionuclides with different half-lives and to demonstrate its utility by examining the clinical implications of prescribing to an isodose surface for such an implant. Methods and Materials: A linear-quadratic model for continuous low dose rate irradiation was developed for permanent implants containing a mixture of radionuclides. Using a generalized equation for the biologically effective dose (BED), the effects of cell proliferation and sublethal damage repair were examined systematically for implants containing a mixture of radionuclides. A head-and-neck permanent seed implant that contained a mixture of 125 I and 103 Pd seeds was used to demonstrate the utility of the generalized BED. Results: An equation of BED for implants containing a mixture of radionuclides with different half-lives was obtained. In such an implant, the effective cell kill was shown to depend strongly on the relative dose contributions from each radionuclide type; dose delivered by radionuclides with shorter half-life always resulted in more cell kill for any given sublethal damage repair and cell proliferation rates. Application of the BED formula to an implant containing a mixture of 125 I and 103 Pd seeds demonstrates that the conventional dose prescription to an isodose surface is not unique for such an implant. When the prescription dose was based on existing clinical experience of using 125 I seeds alone, mixing 103 Pd seeds with 125 I seeds would increase the cell kill. On the other hand, if the prescription dose were based on existing clinical experience of using 103 Pd seeds alone, mixing 125 I seeds with 103 Pd seeds in the same implant would create radiobiologically 'cold' spots (i.e., an increase in cell survival) at locations where a major portion of the prescription dose is contributed by the 125 I seeds. For fast-growing tumors, these 'cold' spots can become significant

  14. CT-guided iodine-125 seed permanent implantation for recurrent head and neck cancers

    Energy Technology Data Exchange (ETDEWEB)

    Jiang, Yu L; Meng, Na; Wang, Jun J; Jiang, Ping [Department of Radiation Oncology, Peking University Third Hospital, Beijing 100191 (China); Yuan, Hui SH; Liu, Chen [Department of Radiology, Peking University Third Hospital, Beijing, 100191 (China); Qu, Ang; Yang, Rui J [Department of Radiation Oncology, Peking University Third Hospital, Beijing 100191 (China)

    2010-07-30

    To investigate the feasibility, and safety of {sup 125}I seed permanent implantation for recurrent head and neck carcinoma under CT-guidance. A retrospective study on 14 patients with recurrent head and neck cancers undergone {sup 125}I seed implantation with different seed activities. The post-plan showed that the actuarial D90 of {sup 125}I seeds ranged from 90 to 218 Gy (median, 157.5 Gy). The follow-up was 3 to 60 months (median, 13 months). The median local control was 18 months (95% CI, 6.1-29.9 months), and the 1-, 2-, 3-, and 5- year local controls were 52%, 39%, 39%, and 39%, respectively. The 1-, 2-, 3-, and 5- survival rates were 65%, 39%, 39% and 39%, respectively, with a median survival time of 20 months (95% CI, 8.7-31.3 months). Of all patients, 28.6% (4/14) died of local recurrence, 7.1% (1/14) died of metastases, one patient died of hepatocirrhosis, and 8 patients are still alive to the date of data analysis. CT-guided {sup 125}I seed implantation is feasible and safe as a salvage or palliative treatment for patients with recurrent head and neck cancers.

  15. [125I]Iodopride

    International Nuclear Information System (INIS)

    Janowsky, A.; Ebert, M.H.; De Paulis, T.; Vanderbilt Univ., Nashville, TN; Kessler, R.M.; Vanderbilt Univ., Nashville, TN; Clanton, J.A.; Smith, H.E.

    1988-01-01

    Substituted benzamides are currently among the most selective antagonists at dopamine D-2 receptors, and high affinity ligands have been developed by substituting halogens into the aromatic ring of the benzamides. The authors report the high affinity, stereoselective, reversible, and sodium dependent binding of a new iodine-substituted benzamide, called [ 125 I]iodopride, to a membrane preparation from rat corpus striatum. 5 refs.; 1 figure

  16. The effect of local control on metastatic dissemination in carcinoma of the prostate: Long-term results in patients treated with 125I implantation

    International Nuclear Information System (INIS)

    Fuks, Z.; Leibel, S.A.; Wallner, K.E.; Begg, C.B.; Fair, W.R.; Anderson, L.L.; Hilaris, B.S.; Whitmore, W.F.

    1991-01-01

    The study evaluates the effect of the locally recurring tumor on the incidence of metastatic disease in early stage carcinoma of the prostate. The probability of distant metastases was studied in 679 patients with Stage B-C/N0 carcinoma of the prostate treated at MSKCC between 1970 and 1985 (median follow-up of 97 months). Patients were staged with pelvic lymph node dissection and treated with retropubic 125I implantation. The actuarial distant metastases free survival (DMFS) for patients at risk at 15 years after initial therapy was 37%. Cox proportional hazard regression analysis of covariates affecting the metastatic outcome showed that local failure, used in the model as a time dependent variable, was the most significant covariate, although stage, grade, and implant volume were also found to be independent variables. The relative risk of metastatic spread subsequent to local failure was 4-fold increased compared to the risk without evidence of local relapse. The 15-year actuarial DMFS in 351 patients with local control was 77% compared to 24% in 328 patients who developed local relapses (p less than 0.00001). The relation of distant spread to the local outcome was observed regardless of stage, grade, or implant dose. Even stage B1/N0-Grade I patient with local control showed a 15-year actuarial DMFS of 82%, compared to 22% in patients with local relapse (p less than 0.00001). The median local relapse-free survival (LRFS) in the 268 patients with local recurrences who did not receive hormonal therapy before distant metastases were detected was 51 months, compared to a median of 71 months for DMFS in the same patients (p less than 0.001), consistent with the possibility that distant dissemination may develop secondary to local failure

  17. The contamination on farm products from 125I

    International Nuclear Information System (INIS)

    Zhao Wenhu; Xu Shiming; Hou Lanxin

    1990-02-01

    The 125 I contamination on 15 farm products have been investigated. The effects of 12 farm crops (wheat, bean, eggplants and other vegetables) contaminated by 125 I during the growing stage on their fruits and seeds have been studied. The results show that the 125 I radioactive substance is mainly concentrated on the fruit surface, and the radioactivity rapidly decreased towards its kernel. The fruits and seeds would not be contaminated when plants were contaminated in the seedling stage

  18. Intraoperative ultrasound quided iodine-125 seed implantation for unresectable pancreatic carcinoma

    International Nuclear Information System (INIS)

    Wang Junjie; Liu Jiangping; Jiang Yuliang; Jiang Weijuan; Li Jinna; Xiu Dianrong; Ran Weiqiang

    2007-01-01

    Objective: To investigate the surgical technique, efficacy and side effects of intraoperative ultrasound quided 125 I seed interstitial implantation for pancreatic carcinoma. Methods: Twenty-seven patients with biopsy proven unresectable adenocarcinoma of pancreas were treated with 125 I implants during laparotomy. Eleven patients were treated by a combination of bypass surgery. Seed needles were implanted parallel to each other, at 1.0-1.5 cm apart and guided by ultrasound. Mick applicator was applied to each needle to implant seed at 1.0-1.5 cm apart. The radioactive activity ranged 0.40-0.70 mCi; the D 90 were 110-160 Gy. The mean number of 125 I seed were 11-78. Six patients also received external beam radiation at doses of 39-50 Gy. Five patients received 2-4 cycle DDP + gemCitabine chemotherapy also. Results: The incidence of perioperative mortality was 0%. Pain was complete relieved in 15 patients, partial relieved in two, but in the rest three patients there was no response. The response rate was 85%. The starting time of pain relief was 1-30 d, with a median of 5 days. The overall local control rate was 74%. Four patients have died of recurrence, 20 patients died of metastasis, 3 patients died of recurrence and metastasis. The median survival of II + III[ stage patients was 8 months, with a 1- and 2-year survival of 25% and 15%, respectively. The median survival time of IV stage patients was 5 months, with 1-year survival of 8%. The seeds immigrated into the liver in 3 patients. There are no serious side effects such as infection or pancreatic fistula. Conclusions: Intraoperative ultrasound quided 125 I seed implantation is safe, giving high local control, but minimal damage. It is a satisfactorily palliative for pain and causing little noticeable complications. (authors)

  19. Iodine-125 seed implantation for unresectable pancreatic carcinoma guided by intraoperative ultrasound

    International Nuclear Information System (INIS)

    Wang Junjie; Xiu Dianrong; Ran Weiqiang; Bai Jing; Zhu Lihong; Liu Jiangping

    2005-01-01

    Objective: To investigate the surgical technique, efficacy and side effects of 125 I seed interstitial implantation for pancreatic carcinoma. Methods: A total of 22 patients with biopsy proven unresectable adenocarcinoma of pancreas were treated with 125 I implants during laparotomy. Of them 11 patients were treated previously by a combination of bypass surgery. The stent was implanted in 2 cases 2 weeks before and 4 weeks after seed implantation. Seed needles were implanted parallelly to each other, with 1-1.5 cm apart. Mick applicator was being connected to each needle to implant seed. The radioactive activity ranged 0.40-0.70 mCi, the matched peripheral doses were 65-145 Gy. The mean number of 125 I seed was 11-78. Five cases received external beam irradiation with 3D-CRT, the doses were 39-70 Gy and 5 patients received 2 cycle of gemcitabine chemotherapy at 1000 mg/m 2 on dl and d8. Results: Pain was completely relieved in 12 cases, partially relieved in 2 cases, and no response was noted in one case, so the response rate was 93.33%. The median time was 2-3 d. Altogethe 27.27% of the cases died from local recurrence of pancreatic carcinoma and 50% from metastasis. The median survival time in these patients was 6 months, with a 2-year survival rate of 9.09%. The seed immigrated to liver in 3 cases. There were no serious side effects such as infection, pancreatitis, pancreatic fistula, etc. Conclusion: Radioactive seed implantation was safe, high local control, minidamage, satisfactory palliation of pain and without significant complications. (authors)

  20. Clinical application of permanent implantation of iodine 125 seeds for osseous metastases

    International Nuclear Information System (INIS)

    Li Jinxin; Zhang Qizhou; Li Guoliang

    2010-01-01

    Objective: To evaluate the clinical efficacy of permanent implantation of iodine 125 seeds in the treatment of osseous metastases. Methods: Radioactive iodine 125 seeds were implanted permanently in 32 lesions of 25 patients with osseous metastases of different origins. The ostalgia-relieving degree and the imaging alterations of the osseous metastasis lesions were observed. Results: The effective pain-relieving rate was 92% caused by permanent implantation of iodine 125 seeds. Of al 1 the patients, 15 patients achieved complete response, 8 patients obtained partial response (PR), and 2 patients had no change. The pain grade was decreased significantly after the treatment (P 125 I seeds has a definite effect on tumor metastasis and caused minimal damage and few complications. It is worthy of popularization in clinic. (authors)

  1. Seed loss through the urinary tract after prostate brachytherapy: examining the role of cystoscopy and urine straining post implant

    International Nuclear Information System (INIS)

    Stutz, Michael; Petrikas, James; Raslowsky, Michael; Lee, Plato; Gurel, Michelle; Moran, Brian

    2003-01-01

    This study describes one institution's experience with seed retrieval through the urinary tract and makes recommendations for cystoscopy and urine straining post prostate brachytherapy (PB). 1794 patients from two separate cohorts covering different time periods (early versus late) were analyzed. All patients were preplanned with a modified peripheral loading technique and implanted with preloaded needles ( 125 I or 103 Pd) under ultrasound guidance. A catheter was used to delineate the urethra during the volume study but was not used during the implant. All patients underwent post implant cystoscopy. All patients were instructed to strain their urine for seven days post implant and return any seeds to our center. In our experience, seed loss through the urinary tract is a common event after PB, occurring in 29.7% of patients and was more common in patients from the early cohort, those implanted with 125 I seeds or those patients with prior transurethral resection of the prostate. Average seed loss per case, however, represents only 0.58% of total activity. We continue to recommend routine post implant cystoscopy for seed retrieval and periprocedural management. We no longer recommend that patients strain their urine at home after documenting a low rate of seed loss after discharge

  2. Air density dependence of the response of the PTW SourceCheck 4pi ionization chamber for 125I brachytherapy seeds.

    Science.gov (United States)

    Torres Del Río, J; Tornero-López, A M; Guirado, D; Pérez-Calatayud, J; Lallena, A M

    2017-06-01

    To analyze the air density dependence of the response of the new SourceCheck 4pi ionization chamber, manufactured by PTW. The air density dependence of three different SourceCheck 4pi chambers was studied by measuring 125 I sources. Measurements were taken by varying the pressure from 746.6 to 986.6hPa in a pressure chamber. Three different HDR 1000 Plus ionization chambers were also analyzed under similar conditions. A linear and a potential-like function of the air density were fitted to experimental data and their achievement in describing them was analyzed. SourceCheck 4pi chamber response showed a residual dependence on the air density once the standard pressure and temperature factor was applied. The chamber response was overestimated when the air density was below that under normal atmospheric conditions. A similar dependence was found for the HDR 1000 Plus chambers analyzed. A linear function of the air density permitted a very good description of this residual dependence, better than with a potential function. No significant variability between the different specimens of the same chamber model studied was found. The effect of overestimation observed in the chamber responses once they are corrected for the standard pressure and temperature may represent a non-negligible ∼4% overestimation in high altitude cities as ours (700m AMSL). This overestimation behaves linearly with the air density in all cases analyzed. Copyright © 2017 Associazione Italiana di Fisica Medica. Published by Elsevier Ltd. All rights reserved.

  3. Postenucleation orbits in retinoblastoma: treatment with 125I brachytherapy

    International Nuclear Information System (INIS)

    Stannard, Clare; Sealy, Ross; Hering, Egbert; Hough, Jan; Knowles, Ruth; Lecuona, Karin; Reddi, V. Bala

    2002-01-01

    Purpose: Children with retinoblastoma that extends into or through the choroid, sclera, or optic nerve are at risk of developing orbital disease, as well as metastases. Previously, these enucleated orbits were treated with external beam radiotherapy in addition to chemotherapy. 125 I brachytherapy for tumors in and around the eye was pioneered by Sealy in Cape Town, South Africa, in 1974. In 1983, he developed a technique to irradiate the contents of the orbit while limiting the dose to the bony orbit and eyelids. Methods and Materials: Six nylon tubes containing 125 I seeds were implanted through the eyelids around the periphery of the orbit. Each contained a metal gutter that screens the outer part of the seeds from the bony orbit. A seventh unscreened tube was placed in the center, and a metal disc with 125 I seeds on its posterior surface was secured beneath the eyelids. Between 1983 and 2000, 57 orbits were treated in 56 children with retinoblastoma. Thirty-six were treated prophylactically and 21, with tumor at the resection line of the nerve, extrascleral tumor, or metastases, were treated therapeutically. They received a median dose of 34 Gy in 70 h; 30 also received chemotherapy. Children with tumor at the resection line of the nerve also received treatment to the craniospinal axis. Results: The median follow-up of the 35 patients treated prophylactically was 35 months (range 0-187). Seven patients died, 6 of metastases, at a median of 10 months (range 4-29) after the implant. Eight of the 13 patients with microscopic extraocular tumor survived a median of 29 months (range 5-156). None of the 8 patients presenting with orbital tumor or metastases survived. No orbital recurrences developed in any of the patients. Cosmesis was considerably improved compared with previous forms of irradiation. Conclusion: Orbital brachytherapy is an effective method of irradiating the orbit to prevent recurrent tumor, the treatment time is short, and the cosmesis is much more

  4. Angular and radial dependence of the energy response factor for LiF-TLD micro-rods in 125I permanent implant source

    International Nuclear Information System (INIS)

    Mobit, P.; Badragan, I.

    2006-01-01

    EGSnrc Monte Carlo simulations were used to calculate the angular and radial dependence of the energy response factor for LiF-thermoluminescence dosemeters (TLDs) irradiated with a commercially available 125 I permanent brachytherapy source. The LiF-TLDs were modelled as cylindrical micro-rods of length 6 mm and with diameters of 1 mm and 5 mm. The results show that for a LiF-TLD micro-rod of 1 mm diameter, the energy response relative to 60 Co gamma rays is 1.406 ± 0.3% for a polar angle of 90 deg. and radial distance of 1.0 cm. When the diameter of the micro-rod is increased from 1 to 5 mm, the energy response decreases to 1.32 ± 0.3% at the same point. The variation with position of the energy response factor is not >5% in a 6 cm x 6 cm x 6 cm calculation grid for the 5 mm diameter micro-rod. The results show that there is a change in the photon spectrum with angle and radial distance, which causes the variation of the energy response. (authors)

  5. Nutritional prognostic scores in patients with hilar cholangiocarcinoma treated by percutaneous transhepatic biliary stenting combined with 125I seed intracavitary irradiation: A retrospective observational study.

    Science.gov (United States)

    Cui, Peiyuan; Pang, Qing; Wang, Yong; Qian, Zhen; Hu, Xiaosi; Wang, Wei; Li, Zongkuang; Zhou, Lei; Man, Zhongran; Yang, Song; Jin, Hao; Liu, Huichun

    2018-06-01

    We mainly aimed to preliminarily explore the prognostic values of nutrition-based prognostic scores in patients with advanced hilar cholangiocarcinoma (HCCA).We retrospectively analyzed 73 cases of HCCA, who underwent percutaneous transhepatic biliary stenting (PTBS) combined with I seed intracavitary irradiation from November 2012 to April 2017 in our department. The postoperative changes of total bilirubin (TBIL), direct bilirubin (DBIL), alanine aminotransferase (ALT), aspartate aminotransferase (AST), alkaline phosphatase (ALP), and albumin (ALB) were observed. The preoperative clinical data were collected to calculate the nutrition-based scores, including controlling nutritional status (CONUT), C-reactive protein/albumin ratio (CAR), and prognostic nutritional index (PNI). Kaplan-Meier curve and Cox regression model were used for overall survival (OS) analyses.The serum levels of TBIL, DBIL, ALT, AST, and ALP significantly reduced, and ALB significantly increased at 1 month and 3 months postoperatively. The median survival time of the cohort was 12 months and the 1-year survival rate was 53.1%. Univariate analysis revealed that the statistically significant factors related to OS were CA19-9, TBIL, ALB, CONUT, and PNI. Multivariate analysis further identified CA19-9, CONUT, and PNI as independent prognostic factors.Nutrition-based prognostic scores, CONUT and PNI in particular, can be used as predictors of survival in unresectable HCCA.

  6. Dosimetric results in implant and post-implant and low rate in brachytherapy prostate cancer with loose seeds and attached; Resultados dosimetricos en el implante y post-impante en braquiterapia de baja tasa en cancer de prostata con semillas sueltas y unidas

    Energy Technology Data Exchange (ETDEWEB)

    Juan-Senabre, X. J.; Albert Antequera, M.; Lopez-Tarjuelo, J.; Santos Serra, A.; Perez-Mestre, M.; Sanchez Iglesias, A. L.; Conde Moreno, A. J.; Gonzalez Vidal, V.; Beltran Persiva, J.; Muelas Soria, R.; Ferrer Albiach, C.

    2015-07-01

    The objective is determine differences dosimetry statistics on the dosimetry of the implant and post-implant in brachytherapy of low rate with implants permanent in prostate using seed of 125-I loose and attached Both in lives and in the post-prostatic plans dosimetric coverage is good and restrictions in urethra and rectum for both groups of patients are met. Not migrating with joined is evident, as well as better dosimetric homogeneity. (Author)

  7. The effect of the radial function on I-125 seeds used for permanent prostate implantation

    International Nuclear Information System (INIS)

    Pickett, Barby; Pouliot, Jean

    2004-01-01

    The purpose of this study was to evaluate the integrity of eight commercially-available low-activity Iodine-125 ( 125 I) seeds for their radial function g(r) and its effect on the dose delivered to the adjacent critical structures when used in permanent prostate implants (PPI). Ten previously treated patients were retrospectively used in this comparison. The Amersham Health Oncura seed was used to peripherally design an isodose distribution with urethral and anterior rectal wall sparing. Plan criteria included minimum coverage of 144 Gy to the planning target volume (PTV), ≤ 70% dose to 150% of the PTV volume (V150-PTV), and the quantity of needles ≤ 70% of the size of the PTV, in cc. Upon completion of the Oncura plan, the seed type was changed and the activity was adjusted until the V100-PTV for each of the other 7 seed types matched the V100-PTV defined by the Oncura seed. Computed tomography (CT)-based postimplant dosimetry was used to determine the dose to 40% (D40) of the bulb of the penis (in Gy). Dose-volume histograms (DVH) were used to evaluate the differences to V100 (in %) and D40 (in Gy) of the anterior rectal wall and bulb of the penis, and V100 (in %) of the urethra. The data was tabulated. Radioactive 125 I sources included in this study were 125 I Source 2301 (Best); I-Plant (MedTech), IoGold (Mentor), Oncura (Amersham Health), ProstaSeed (UroCor), SelectSeed (Nucletron), SourceTech (Bard), and Symmetra (UroMed). The sizes of the PTV for the 10 patients ranged from 18.82 cc to 48.99 cc. The Oncura seed was used as the reference seed and all other seed types were normalized to it for data comparison. It was determined that the dose rate constant (xwedge) and anisotropy factor (phi) contribute to the activity needed to achieve comparable V100-PTV doses, but a strong dependence on the radial function g(r) was found to effect the doses to the critical structures studied. Values of g(r) at 4 cm were calculated and the IoGold and SourceTech seeds

  8. A traceability establishment for the 125I IsoSeed I25.S06 source from Bebig at the hospital level; Propuesta de obtencion de trazabilidad a nivel hospitalario para la fuente de 125I IsoSeed I25.S06 de Bebig

    Energy Technology Data Exchange (ETDEWEB)

    Perez-Calatayud, J.; Bejar, M.J.; Lliso, F.; Colmenares, R.; Fernandez, J.; Andrassy, M.; Carmona, V.; Ferrer, N.; Vivanco, J.

    2010-07-01

    The purpose of this work has been on one side to solve the traceability problem in hospitals for the I25.S06 seed users, already solved for other seeds, and on the other to design a holder in order to allow the measurement of the reference air-kerma rate for the strand by means of a well-type ionization chamber, widely used in brachytherapy in hospitals. At a joint calibration-measurement session of the involved institutions the following steps were performed: calibration of the HDR 1000 and SourceCheck detectors with a standard source from the Physikalisch-Technische Bundesanstalt (PTB); reference air-kerma rate measurements for the 5 seeds strand provided by Bebig with the SourceCheck detector and with the HDR 1000 detector and the new insert holder by SIHO (Spain); separation of the stranded seeds by the specialist from Bebig who dissolved the plastic; reference air-kerma rate measurement of each of the seeds of the strand with one of the of HDR 1000 detectors previously calibrated. We present the calibration factors obtained and the analysis of the uncertainties associated with the process. (Author).

  9. 1251 seed calibration using afterloading equipment Seed Selectron. Practical solution to meet the recommendations of the AAPM; Calibracion de semillas de {sup 1}25I usando el equipo de carga difereida SeedSelectron. Solucion practica para cumplir las recomendaciones de la AAPM

    Energy Technology Data Exchange (ETDEWEB)

    Perez-Calatayud, J.; Richart, J.; Perez-Garcia, J.; Guirado, D.; Ballester, F.; Rodriguez, S.; Santos, M.; Depiaggio, M.; Carmona, V.; Lliso, F.; Camacho, C.; Pujades, M. C.

    2011-07-01

    Seed Selectron is a system used in the after loader permanent implant brachytherapy seeds 1-125 interstitial prostate. Two aspects are critical when you can meet the recommendations of the AAPM: a practical difficulty to check the quantity of seed required, and the great uncertainty of all measured diodes. The purpose of this paper is to present a practical solution that has been adopted to implement the recommendations of the AAPM.

  10. Iodine-125 seed implantation (permanent brachytherapy) for clinically localized prostate cancer

    International Nuclear Information System (INIS)

    Ebara, Shin; Katayama, Yoshihisa; Tanimoto, Ryuta

    2008-01-01

    From January 2004 to March 2007, 308 patients with clinically localized prostate cancer were treated using iodine-125 ( 125 I) seed implantation (permanent brachytherapy) at Okayama University Graduate School of Medicine, Dentistry and Pharmaceutical Sciences. We evaluated the treatment's efficacy and morbidity in 300 prostate cancer patients who were followed up for more than 1 month after brachytherapy. Based on the National Comprehensive Cancer Network (NCCN) guidelines, patients with a prostate volume of less than 40 ml in transrectal ultrasound imaging were classified as low or intermediate risk. The median patient age was 67 years (range 50 to 79 years), the median prostate-specific antigen (PSA) value before biopsy was 6.95 ng/ml (range 1.13 to 24.7 ng/ml), and the median prostate volume was 24.33 ml (range 9.3 to 41.76 ml). The median follow-up was 18 months (range 1 to 36 months) and the PSA levels decreased in almost all patients after brachytherapy. Although 194 of 300 patients (64.7%) complained of difficulty in urination, pollakisuria/urgency, miction pain, and/or urinary incontinence, all of which might be associated with radiation prostatitis during the first month after brachytherapy, these symptoms gradually improved. 125 I seed implantation brachytherapy is safe and effective for localized prostate cancer within short-term follow up. (author)

  11. Evaluation of radioactive seeds implantation under PET-CT guidance for the treatment of central lung cancer with obstructive atelectasis

    International Nuclear Information System (INIS)

    Zhou Yi; Jiang Zhongpu; Wang Haiting; Zhang Yanjun; Jiang Qiang; Wang Jun; Ren Lijun; Xie Bin

    2010-01-01

    Objective: To evaluate percutaneous puncturing 125 I seed implantation by using PET-CT guided target localization technique in treating central lung cancer complicated by obstructive pulmonary atelectasis. Methods: A total of 30 patients with suspected central lung cancer complicated by obstructive pulmonary atelectasis on preoperative chest films were enrolled in this study. As no clear distinction existed between the tumor and the atelectatic consolidation shadow on plain chest films, CT scanning was carried out in all patients. If CT scan was still not able to determine the margin of the tumor, an additional PET-CT scanning was adopted. After ascertaining the location of the lung cancer, percutaneous puncturing implantation of 125 I seeds under PET-CT guidance was performed. The clinical data and the therapeutic results were evaluated. Results: A sharp distinction between the tumor and the atelectatic consolidation shadow was demonstrated on PET-CT scans in 21 cases. The mean volume of the targeted lesion reckoned from PET-CT scans was 26 cm 3 , and the 125 I seeds were implanted. The mean volume of the targeted lesion calculated on CT scans was 37 cm 3 . Six months after the treatment, the follow-up CT exam showed that the effective rate was 93% (28/30). The one-year survival rate was 100% . The complications included pneumothorax (n = 8), small amount of hemoptysis (n = 12) and fever (n = 2). No displacement or immigration of the implanted seeds occurred. Conclusion: PET-CT scanning is far superior to conventional CT scanning in determining the target area of the tumor in patients with central lung cancer complicated by obstructive pulmonary atelectasis. (authors)

  12. Direct determination of the absorbed dose to water from 125I low dose-rate brachytherapy seeds using the new absorbed dose primary standard developed at ENEA-INMRI

    International Nuclear Information System (INIS)

    Toni, M.P.; Pimpinella, M.; Pinto, M.; Quini, M.; Cappadozzi, G.; Silvestri, C.; Bottauscio, O.

    2012-01-01

    Low-intensity radioactive sources emitting low-energy photons are used in the clinic for low dose-rate brachytherapy treatments of tumours. The dosimetry of these sources is based on reference air kerma rate measurements. The absorbed dose rate to water at the reference depth d 0 = 1 cm, D w , 1 cm, is then obtained by a conversion procedure with a large relative standard uncertainty of about 5%. This paper describes a primary standard developed at ENEA-INMRI to directly measure D w , 1 cm due to LDR sources. The standard is based on a large-angle and variable-volume ionization chamber, embedded in a graphite phantom and operating under 'wall-less air chamber' conditions. A set of correction and conversion factors, based on experiments and Monte Carlo simulations, are determined to obtain the value of D w , 1 cm from measurements of increment of ionization current with increasing chamber volume. The relative standard uncertainty on D w , 1 cm is 2.6%, which is appreciably lower than the current uncertainty. Characteristics of the standard, its associated uncertainty budget, and some experimental results are given for 125 I BEBIG I25.S16.C brachytherapy seeds. Finally, results of the experimental determination of the dose-rate constant 1 cm, traceable to the D w , 1 cm and the low-energy air kerma ENEA-INMRI standards, are given. The relative standard uncertainty on 1 cm is 2.9%, appreciably lower than the typical uncertainty (4.8%) of the values available in the literature. (authors)

  13. SU-E-T-123: Anomalous Altitude Effect in Permanent Implant Brachytherapy Seeds

    International Nuclear Information System (INIS)

    Watt, E; Spencer, DP; Meyer, T

    2015-01-01

    Purpose: Permanent seed implant brachytherapy procedures require the measurement of the air kerma strength of seeds prior to implant. This is typically accomplished using a well-type ionization chamber. Previous measurements (Griffin et al., 2005; Bohm et al., 2005) of several low-energy seeds using the air-communicating HDR 1000 Plus chamber have demonstrated that the standard temperature-pressure correction factor, P TP , may overcompensate for air density changes induced by altitude variations by up to 18%. The purpose of this work is to present empirical correction factors for two clinically-used seeds (IsoAid ADVANTAGE™ 103 Pd and Nucletron selectSeed 125 I) for which empirical altitude correction factors do not yet exist in the literature when measured with the HDR 1000 Plus chamber. Methods: An in-house constructed pressure vessel containing the HDR 1000 Plus well chamber and a digital barometer/thermometer was pumped or evacuated, as appropriate, to a variety of pressures from 725 to 1075 mbar. Current measurements, corrected with P TP , were acquired for each seed at these pressures and normalized to the reading at ‘standard’ pressure (1013.25 mbar). Results: Measurements in this study have shown that utilization of P TP can overcompensate in the corrected current reading by up to 20% and 17% for the IsoAid Pd-103 and the Nucletron I-125 seed respectively. Compared to literature correction factors for other seed models, the correction factors in this study diverge by up to 2.6% and 3.0% for iodine (with silver) and palladium respectively, indicating the need for seed-specific factors. Conclusion: The use of seed specific altitude correction factors can reduce uncertainty in the determination of air kerma strength. The empirical correction factors determined in this work can be applied in clinical quality assurance measurements of air kerma strength for two previously unpublished seed designs (IsoAid ADVANTAGE™ 103 Pd and Nucletron selectSeed 125 I

  14. SU-E-T-123: Anomalous Altitude Effect in Permanent Implant Brachytherapy Seeds

    Energy Technology Data Exchange (ETDEWEB)

    Watt, E; Spencer, DP; Meyer, T [University of Calgary and Tom Baker Cancer Centre, Calgary, AB (Canada)

    2015-06-15

    Purpose: Permanent seed implant brachytherapy procedures require the measurement of the air kerma strength of seeds prior to implant. This is typically accomplished using a well-type ionization chamber. Previous measurements (Griffin et al., 2005; Bohm et al., 2005) of several low-energy seeds using the air-communicating HDR 1000 Plus chamber have demonstrated that the standard temperature-pressure correction factor, P{sub TP}, may overcompensate for air density changes induced by altitude variations by up to 18%. The purpose of this work is to present empirical correction factors for two clinically-used seeds (IsoAid ADVANTAGE™ {sup 103}Pd and Nucletron selectSeed {sup 125}I) for which empirical altitude correction factors do not yet exist in the literature when measured with the HDR 1000 Plus chamber. Methods: An in-house constructed pressure vessel containing the HDR 1000 Plus well chamber and a digital barometer/thermometer was pumped or evacuated, as appropriate, to a variety of pressures from 725 to 1075 mbar. Current measurements, corrected with P{sub TP}, were acquired for each seed at these pressures and normalized to the reading at ‘standard’ pressure (1013.25 mbar). Results: Measurements in this study have shown that utilization of P{sub TP} can overcompensate in the corrected current reading by up to 20% and 17% for the IsoAid Pd-103 and the Nucletron I-125 seed respectively. Compared to literature correction factors for other seed models, the correction factors in this study diverge by up to 2.6% and 3.0% for iodine (with silver) and palladium respectively, indicating the need for seed-specific factors. Conclusion: The use of seed specific altitude correction factors can reduce uncertainty in the determination of air kerma strength. The empirical correction factors determined in this work can be applied in clinical quality assurance measurements of air kerma strength for two previously unpublished seed designs (IsoAid ADVANTAGE™ {sup 103}Pd and

  15. Moving toward focal therapy in prostate cancer: dual-isotope permanent seed implants as a possible solution.

    Science.gov (United States)

    Todor, Dorin A; Barani, Igor J; Lin, Peck-Sun; Anscher, Mitchell S

    2011-09-01

    To compare the ability of single- and dual-isotope prostate seed implants to escalate biologically effective dose (BED) to foci of disease while reducing prescription dose to the prostate. Nine plans, using 125I, 103Pd, and 131Cs alone and in combination were created retrospectively for 2 patients. Ultrasound and MRI/MRS datasets were used for treatment planning. Voxel-by-voxel BED was calculated for single- and dual-isotope plans. Equivalent uniform BED (EUBED) was used to compare plans. The MRS-positive planning target volumes (PTVi) were delineated along with PTV (prostate+5 mm), rectum, and urethra. Single-isotope implants, prescribed to conventional doses, were generated to achieve good PTV coverage. The PTVi were prospectively used to generate implants using mixtures of isotopes. For mixed-radioisotope implants, we also explored the impact on EUBED of lowering prescription doses by 15%. The EUBED of PTVi in the setting of primary 125I implant increased 20-66% when 103Pd and 131Cs were used compared with 125I boost. Decreasing prescription dose by 15% in mixed-isotope implants results in a potential 10% reduction in urethral EUBED with preservation of PTV coverage while still boosting PTVi (up to 80%). When radiobiologic parameters corresponding to more-aggressive disease are assigned to foci, faster-decaying isotopes used in mixed implants have the potential to preserve the equivalent biological effect of mono-isotope implants considering less-aggressive disease distributed in the entire prostate. This is a hypothesis-generating study proposing a treatment paradigm that could be the middle ground between whole-gland irradiation and focal-only treatment. The use of two isotopes concurrent with decreasing the minimal peripheral dose is shown to increase EUBED of selected subvolumes while preserving the therapeutic effect at the level of the gland. Copyright © 2011 Elsevier Inc. All rights reserved.

  16. Synthesis of (125) I-lamivudine and (125) I-lamivudine-ursodeoxycholic acid codrug.

    Science.gov (United States)

    Motaleb, M A; Abo-Kul, M; Ibrahim, Samy M; Saad, Shokry M; Arafat, Muhammad

    2016-09-01

    The preparation of (125) I-lamivudine ((125) I-3TC) and (125) I-lamivudine-ursodeoxycholic acid codrug ((125) I-3TC-UDCA), suitable for comparative biodistribution studies, is described. The synthesis of the unlabeled precursor 3TC-UDCA proceeds in an 11.6% yield, and the radiolabelling yields for (125) I-3TC and (125) I-3TC-UDCA were 89 and 92%, respectively. The final products are radiochemically pure (greater than 98%). Copyright © 2016 John Wiley & Sons, Ltd.

  17. Tumor therapy with 125I-octreotide and 125I-UdR

    International Nuclear Information System (INIS)

    Fan, W.; Zhu, R.; Yang, C.; Sun, J.J.; Xu, Y.J.; Zhang, Y.J.; Wu, M.J.; Wang, D.J.

    2005-01-01

    Purpose: To determine the tumor cell damage effect with Auger-electron emitter 125 I in different chemical states. Methods: (1) [Tyr 3 ] octreotide (TOC) and UdR are labeled with 125 I,respectively. (2) Receptor analysis of 125 I-TOC on small cell lung cancer (SCLC) NCI-H446 cell lines is performed comparing with normal lymph cells. NCI-H446 cells added various dose of 125 I-TOC are incubated for different time with 125 I-Nal and non-labeled TOC as control. The capacity of NCI-H446 cell lines bound and internalization of 125 I TOC are determined. The radiation damage of tumor cells is measured by MTF methods. (3) The killing effects of 125 I-UdR in human pancreatic cancer cell line Bax-Pc and Sca-BER bladder carcinoma cells are evaluated with the similar methods. I-UdR penetrating into the Sca-BER cell nucleus is observed with confocal microscope. The grow suppression and clonogenic formation of Sca-BER cells after incubation with 125 I-UdR are analyzed. Proliferation fraction and S phase cell fraction of Sca-BER cell added 125 I-UdR is measured with flow cytometric analysis. Results: (1) Kd=(0.56∼2.0) x 10 -11 mol/L and B max =(1.17∼2.0) x 10 5 cell site are obtained by receptor analysis of 125 I-TOC on NCI-H446 cells. Comparatively, the difference between total binding and non-specific binding is low and there is no saturation of specific binding for normal lymphocyte. About 50% of 125 I-TOC is internalized into the NCI-H446 cell nucleus at 24h after incubation. The damige of NCI-H446 cells by 125 I-TOC is clearly observed. (2) The penetration amount of 125 I-UdR into cell nucleus increases with the incubate time when the concentration of 125 I-UdR is in the range of 10∼500 kBq/mL and reaches the peak fraction of 94% at 36 h after incubation. The radioactivity of 125 I-UdR is then achieved equelibration and no more increased with time. The linear correlation with γ=0.867∼0.978 between the concentration of 125 I-UdR in cell nucleus and the incubation time

  18. An analysis of brachytherapy with computed tomography-guided permanent implantation of Iodine-125 seeds for recurrent nonkeratin nasopharyngeal carcinoma

    Directory of Open Access Journals (Sweden)

    Shen X

    2015-05-01

    Full Text Available Xinying Shen,1,2 Yong Li,2 Yanfang Zhang,2 Jian Kong,2 Yanhao Li1 1Department of Interventional Radiology, Nanfang Hospital, Southern Medical University, Guangzhou, 2Department of Interventional Radiology, Shenzhen People’s Hospital, The Second Clinical Medical College of Jinan University, Shenzhen, People’s Republic of China Background: 125I seed implantation is a new method in treatment of nasopharyngeal carcinoma (NPC, and it is worthwhile to evaluate its feasibility. In this study, we performed brachytherapy with computed tomography (CT-guided permanent implantation of 125I seeds in the treatment of patients with the recurrence of NPC.Methods: A total 30 patients (20 male and ten female at the median age of 55 (range 25–80 years were diagnosed with recurrent nonkeratin NPC, with a total 38 lesions and a short disease-free interval (median ~11 months after primary radiotherapy alone or combined with chemotherapy. Patients received CT scan, starting from 2 months after the treatment. Follow-up was conducted for ~2–38 months to observe the local control rate and overall survival rate. We also analyzed the possible correlation between survival periods and the status of recurrent tumors.Results: The local control rates at 6, 12, 24, 30, and 36 months after the procedure of 125I seed implantation were 86.8%, 73.7%, 26.3%, 15.8%, and 5.3%, respectively. The overall 1-, 2-, and 3-year survival rates were 80.0% (24/30, 30.0% (9/30, and 6.7% (2/30, respectively, with a median survival period of 18 months (17.6±8.6 months. Interestingly, the survival periods of the patients who had primary radiotherapy with or without chemotherapy were 15.8±7.9 and 24.3±7.9 months, respectively. Kaplan–Meier survival analysis demonstrated that χ2 (log rank was 7.555, with very significant difference (P<0.01. The survival periods of patients in tumor stages I, II, III, and IV were 25.4±8.7, 19.8±9.4, 16.1±4.5, and 12.8±7.8 months, respectively, with

  19. Preparation of 125I FSH hormone

    International Nuclear Information System (INIS)

    Castro de Sabbatini, D.; Nieto de Nunez, G.; Mitta, A.E.A.

    1976-01-01

    Labelling of human FSH of pituitary origin with 125 I and its purification are described. Suitable parameters are selected for the use of radioimmunologic technique for FSH dosage in human serum. (author) [es

  20. Application of 125I in micropipettor check

    International Nuclear Information System (INIS)

    Qian Xiaoyu; Gao Yunchao; Yang Yadong; Lu Hankui

    2006-01-01

    Gravimetric test is one of authoritative methods for the measurement and validation of the accuracy and precision of micropipettors. The feasibility of radioactive measurement in the check of micropipettors is studied. There are no significant difference in radioactive count rates of 125 I aspirated between 2 qualified micropipettors, but significant difference are recorded between qualified and unqualified micropipettors. So 125 I radiometry agrees with gravimetric tests, and can be used as a laboratory constant test of micropipettors. (authors)

  1. Monte Carlo study of LDR seed dosimetry with an application in a clinical brachytherapy breast implant.

    Science.gov (United States)

    Furstoss, C; Reniers, B; Bertrand, M J; Poon, E; Carrier, J-F; Keller, B M; Pignol, J P; Beaulieu, L; Verhaegen, F

    2009-05-01

    A Monte Carlo (MC) study was carried out to evaluate the effects of the interseed attenuation and the tissue composition for two models of 125I low dose rate (LDR) brachytherapy seeds (Medi-Physics 6711, IBt InterSource) in a permanent breast implant. The effect of the tissue composition was investigated because the breast localization presents heterogeneities such as glandular and adipose tissue surrounded by air, lungs, and ribs. The absolute MC dose calculations were benchmarked by comparison to the absolute dose obtained from experimental results. Before modeling a clinical case of an implant in heterogeneous breast, the effects of the tissue composition and the interseed attenuation were studied in homogeneous phantoms. To investigate the tissue composition effect, the dose along the transverse axis of the two seed models were calculated and compared in different materials. For each seed model, three seeds sharing the same transverse axis were simulated to evaluate the interseed effect in water as a function of the distance from the seed. A clinical study of a permanent breast 125I implant for a single patient was carried out using four dose calculation techniques: (1) A TG-43 based calculation, (2) a full MC simulation with realistic tissues and seed models, (3) a MC simulation in water and modeled seeds, and (4) a MC simulation without modeling the seed geometry but with realistic tissues. In the latter, a phase space file corresponding to the particles emitted from the external surface of the seed is used at each seed location. The results were compared by calculating the relevant clinical metrics V85, V100, and V200 for this kind of treatment in the target. D90 and D50 were also determined to evaluate the differences in dose and compare the results to the studies published for permanent prostate seed implants in literature. The experimental results are in agreement with the MC absolute doses (within 5% for EBT Gafchromic film and within 7% for TLD-100

  2. Dosimetric effects of edema in permanent prostate seed implants: a rigorous solution

    International Nuclear Information System (INIS)

    Chen Zhe; Yue Ning; Wang Xiaohong; Roberts, Kenneth B.; Peschel, Richard; Nath, Ravinder

    2000-01-01

    Purpose: To derive a rigorous analytic solution to the dosimetric effects of prostate edema so that its impact on the conventional pre-implant and post-implant dosimetry can be studied for any given radioactive isotope and edema characteristics. Methods and Materials: The edema characteristics observed by Waterman et al (Int. J. Rad. Onc. Biol. Phys, 41:1069-1077; 1998) was used to model the time evolution of the prostate and the seed locations. The total dose to any part of prostate tissue from a seed implant was calculated analytically by parameterizing the dose fall-off from a radioactive seed as a single inverse power function of distance, with proper account of the edema-induced time evolution. The dosimetric impact of prostate edema was determined by comparing the dose calculated with full consideration of prostate edema to that calculated with the conventional dosimetry approach where the seed locations and the target volume are assumed to be stationary. Results: A rigorous analytic solution on the relative dosimetric effects of prostate edema was obtained. This solution proved explicitly that the relative dosimetric effects of edema, as found in the previous numerical studies by Yue et. al. (Int. J. Radiat. Oncol. Biol. Phys. 43, 447-454, 1999), are independent of the size and the shape of the implant target volume and are independent of the number and the locations of the seeds implanted. It also showed that the magnitude of relative dosimetric effects is independent of the location of dose evaluation point within the edematous target volume. It implies that the relative dosimetric effects of prostate edema are universal with respect to a given isotope and edema characteristic. A set of master tables for the relative dosimetric effects of edema were obtained for a wide range of edema characteristics for both 125 I and 103 Pd prostate seed implants. Conclusions: A rigorous analytic solution of the relative dosimetric effects of prostate edema has been

  3. Urinary morbidity following ultrasound-guided transperineal prostate seed implantation

    International Nuclear Information System (INIS)

    Gelblum, Daphna Y.; Potters, Louis; Ashley, Richard; Waldbaum, Robert; Wang Xiaohong; Leibel, Steven

    1999-01-01

    Purpose: To assess the urinary morbidity experienced by patients undergoing ultrasound-guided, permanent transperineal seed implantation for adenocarcinoma of the prostate. Methods and Materials: Between September 1992 and September 1997, 693 consecutive patients presented with a diagnosis of clinically localized adenocarcinoma of the prostate, and were treated with ultrasound-guided transperineal interstitial permanent brachytherapy (TPIPB). Ninety-three patients are excluded from this review, having received neoadjuvant antiandrogen therapy. TPIPB was performed with 125 I in 165 patients and with 103 Pd in 435 patients. Patients treated with implant alone received 160 Gy with 125 I (pre TG43) or 120 Gy with 103 Pd. One hundred two patients received preimplant, pelvic external beam radiation (XRT) to a dose of either 41.4 or 45 Gy because of high-risk features including PSA ≥ 10 and/or Gleason score ≥ 7. Combined modality patients received 120 Gy and 90 Gy, respectively for 125 I or 103 Pd. All patients underwent postimplant cystoscopy and placement of an indwelling Foley catheter for 24-48 h. Follow-up was at 5 weeks after implant, every 3 months for the first 2 years, and then every 6 months for subsequent years. Patients completed AUA urinary symptom scoring questionnaires at initial consultation and at each follow-up visit. Urinary toxicity was classified by the RTOG toxicity scale with the following adaptations; grade 1 urinary toxicity was symptomatic nocturia or frequency requiring none or minimal medical intervention such as phenazopyridine; grade 2 urinary toxicity was early obstructive symptomatology requiring alpha-blocker therapy; and grade 3 toxicity was considered that requiring indwelling catheters or posttreatment transurethral resection of the prostate for symptom relief. Log-rank analysis and Chi-square testing was performed to assess AUA score, prostate size, isotope selection, and the addition of XRT as possible prognosticators of

  4. Exposure dose estimation of nursing personnel and visitors following "1"2"5I brachytherapy

    International Nuclear Information System (INIS)

    Nakazato, Kazuhisa; Kikuchi, Hirosumi; Hotta, Harumi; Nishizawa, Kunihide

    2007-01-01

    An automated access management system to the controlled sickrooms for "1"2"5I brachytherapy was developed. The system consists of access control and video surveillance units. The patients implanted "1"2"5I seeds were isolated for about 20 h after surgery in the controlled sickrooms. The maximum doses and dose rates of the nurses and visitors were estimated by using the legal upper limit activity of 1,300 MBq, the measured longest staying time, and the shortest distance between the patients and individuals. Video analysis revealed activities of the nurses, patients, and visitors in the controlled sickroom, and relationships between the access frequency and staying time. The nurses' measured doses ranged from 1 to 3 μSv, and averaged 1.6 μSv. The nurses' maximum dose and dose rate were 16 μSv and 5.6 nSv·h"-"1·MBq"-"1. The visitors' maximum dose and dose rate were 6 μSv and 2.6 nSv·h"-"1·MBq"-"1. The nurses and visitors' exposure doses per patient were estimated to be negligible compared with the annual limit of the public. (author)

  5. Seed Implant Retention Score Predicts the Risk of Prolonged Urinary Retention After Prostate Brachytherapy

    International Nuclear Information System (INIS)

    Lee, Hoon K.; Adams, Marc T.; Shi, Qiuhu; Basillote, Jay; LaMonica, Joanne; Miranda, Luis; Motta, Joseph

    2010-01-01

    Purpose: To risk-stratify patients for urinary retention after prostate brachytherapy according to a novel seed implant retention score (SIRS). Patients and Methods: A total of 835 patients underwent transperineal prostate seed implant from March 1993 to January 2007; 197 patients had 125 I and 638 patients had 103 Pd brachytherapy. Four hundred ninety-four patients had supplemental external-beam radiation. The final downsized prostate volume was used for the 424 patients who had neoadjuvant hormone therapy. Retention was defined as reinsertion of a Foley catheter after the implant. Results: Retention developed in 7.4% of patients, with an average duration of 6.7 weeks. On univariate analysis, implant without supplemental external-beam radiation (10% vs. 5.6%; p = 0.02), neoadjuvant hormone therapy (9.4% vs. 5.4%; p = 0.02), baseline α-blocker use (12.5% vs. 6.3%; p = 0.008), and increased prostate volume (13.4% vs. 6.9% vs. 2.9%, >45 cm 3 , 25-45 cm 3 , 3 ; p = 0.0008) were significantly correlated with increased rates of retention. On multivariate analysis, implant without supplemental external-beam radiation, neoadjuvant hormone therapy, baseline α-blocker use, and increased prostate volume were correlated with retention. A novel SIRS was modeled as the combined score of these factors, ranging from 0 to 5. There was a significant correlation between the SIRS and retention (p < 0.0001). The rates of retention were 0, 4%, 5.6%, 9%, 20.9%, and 36.4% for SIRS of 0 to 5, respectively. Conclusions: The SIRS may identify patients who are at high risk for prolonged retention after prostate brachytherapy. A prospective validation study of the SIRS is planned.

  6. Seed Placement in Permanent Breast Seed Implant Brachytherapy: Are Concerns Over Accuracy Valid?

    Energy Technology Data Exchange (ETDEWEB)

    Morton, Daniel, E-mail: dmorton@bccancer.bc.ca [Department of Medical Physics, BC Cancer Agency, Centre for the Southern Interior, Kelowna, British Columbia (Canada); Department of Physics and Astronomy, University of Victoria, Victoria, British Columbia (Canada); Hilts, Michelle [Department of Medical Physics, BC Cancer Agency, Centre for the Southern Interior, Kelowna, British Columbia (Canada); Department of Physics and Astronomy, University of Victoria, Victoria, British Columbia (Canada); Batchelar, Deidre [Department of Medical Physics, BC Cancer Agency, Centre for the Southern Interior, Kelowna, British Columbia (Canada); Crook, Juanita [Department of Radiation Oncology, BC Cancer Agency, Centre for the Southern Interior, Kelowna, British Columbia (Canada)

    2016-07-01

    Purpose: To evaluate seed placement accuracy in permanent breast seed implant brachytherapy (PBSI), to identify any systematic errors and evaluate their effect on dosimetry. Methods and Materials: Treatment plans and postimplant computed tomography scans for 20 PBSI patients were spatially registered and used to evaluate differences between planned and implanted seed positions, termed seed displacements. For each patient, the mean total and directional seed displacements were determined in both standard room coordinates and in needle coordinates relative to needle insertion angle. Seeds were labeled according to their proximity to the anatomy within the breast, to evaluate the influence of anatomic regions on seed placement. Dosimetry within an evaluative target volume (seroma + 5 mm), skin, breast, and ribs was evaluated to determine the impact of seed placement on the treatment. Results: The overall mean (±SD) difference between implanted and planned positions was 9 ± 5 mm for the aggregate seed population. No significant systematic directional displacements were observed for this whole population. However, for individual patients, systematic displacements were observed, implying that intrapatient offsets occur during the procedure. Mean displacements for seeds in the different anatomic areas were not found to be significantly different from the mean for the entire seed population. However, small directional trends were observed within the anatomy, potentially indicating some bias in the delivery. Despite observed differences between the planned and implanted seed positions, the median (range) V{sub 90} for the 20 patients was 97% (66%-100%), and acceptable dosimetry was achieved for critical structures. Conclusions: No significant trends or systematic errors were observed in the placement of seeds in PBSI, including seeds implanted directly into the seroma. Recorded seed displacements may be related to intrapatient setup adjustments. Despite observed seed

  7. More accurate fitting of 125I and 103Pd radial dose functions

    International Nuclear Information System (INIS)

    Taylor, R. E. P.; Rogers, D. W. O.

    2008-01-01

    In this study an improved functional form for fitting the radial dose functions, g(r), of 125 I and 103 Pd brachytherapy seeds is presented. The new function is capable of accurately fitting radial dose functions over ranges as large as 0.05 cm≤r≤10 cm for 125 I seeds and 0.10 cm≤r≤10 cm for 103 Pd seeds. The average discrepancies between fit and calculated data are less than 0.5% over the full range of fit and maximum discrepancies are 2% or less. The fitting function is also capable of accounting for the sharp increase in g(r) (upturn) seen for some sources for r 125 I seeds and 9 103 Pd seeds using the EGSnrc Monte Carlo user-code BrachyDose. Fitting coefficients of the new function are tabulated for all 27 seeds. Extrapolation characteristics of the function are also investigated. The new functional form is an improvement over currently used fitting functions with its main strength being the ability to accurately fit the rapidly varying radial dose function at small distances. The new function is an excellent candidate for fitting the radial dose function of all 103 Pd and 125 I brachytherapy seeds and will increase the accuracy of dose distributions calculated around brachytherapy seeds using the TG-43 protocol over a wider range of data. More accurate values of g(r) for r<0.5 cm may be particularly important in the treatment of ocular melanoma

  8. Preparation of 125I labelled compound

    International Nuclear Information System (INIS)

    Rafii, H.; Beiki, D.; Matlubi, M.; Jalilian, A.R.; Motamedi, F.; Karimian, A.R.; Najafi, R.; Babaei, M.; Kamali Dehghan, M.; Shah-Hossaini, G.R.; Shafahi, S.K.; Keshavarzi, F.

    2002-01-01

    Iodinated compounds with 131 I, 125 I and 123 I have been widely used for biochemical function studies. In conjunction with SPECT, [ 123 I] labelled proteins have various diagnostic and therapeutic applications in nuclear medicine. In this study, synthesis and quality control of [ 18 F]radiofluorinated and radioiodinated of some proteins and peptides as well as their biological behaviors are considered to be investigated. (author)

  9. Automated treatment planning engine for prostate seed implant brachytherapy

    International Nuclear Information System (INIS)

    Yu Yan; Zhang, J.B.Y.; Brasacchio, Ralph A.; Okunieff, Paul G.; Rubens, Deborah J.; Strang, John G.; Soni, Arvind; Messing, Edward M.

    1999-01-01

    Purpose: To develop a computer-intelligent planning engine for automated treatment planning and optimization of ultrasound- and template-guided prostate seed implants. Methods and Materials: The genetic algorithm was modified to reflect the 2D nature of the implantation template. A multi-objective decision scheme was used to rank competing solutions, taking into account dose uniformity and conformity to the planning target volume (PTV), dose-sparing of the urethra and the rectum, and the sensitivity of the resulting dosimetry to seed misplacement. Optimized treatment plans were evaluated using selected dosimetric quantifiers, dose-volume histogram (DVH), and sensitivity analysis based on simulated seed placement errors. These dosimetric planning components were integrated into the Prostate Implant Planning Engine for Radiotherapy (PIPER). Results: PIPER has been used to produce a variety of plans for prostate seed implants. In general, maximization of the minimum peripheral dose (mPD) for given implanted total source strength tended to produce peripherally weighted seed patterns. Minimization of the urethral dose further reduced the loading in the central region of the PTV. Isodose conformity to the PTV was achieved when the set of objectives did not reflect seed positioning uncertainties; the corresponding optimal plan generally required fewer seeds and higher source strength per seed compared to the manual planning experience. When seed placement uncertainties were introduced into the set of treatment planning objectives, the optimal plan tended to reach a compromise between the preplanned outcome and the likelihood of retaining the preferred outcome after implantation. The reduction in the volatility of such seed configurations optimized under uncertainty was verified by sensitivity studies. Conclusion: An automated treatment planning engine incorporating real-time sensitivity analysis was found to be a useful tool in dosimetric planning for prostate

  10. Treatment of hepatocellular carcinoma adjacent to large blood vessels using 1.5T MRI-guided percutaneous radiofrequency ablation combined with iodine-125 radioactive seed implantation

    Energy Technology Data Exchange (ETDEWEB)

    Lin, Zheng-Yu, E-mail: linsinlan@yahoo.com.cn [The Department of Radiology, First Affiliated Hospital of Fujian Medical University, 20 Chazhong Road, Fuzhou 350005 (China); Chen, Jin, E-mail: snow8968851@163.com [The Department of Radiology, First Affiliated Hospital of Fujian Medical University, 20 Chazhong Road, Fuzhou 350005 (China); Deng, Xiu-Fen, E-mail: dxf197286@yahoo.com.cn [The Department of Radiology, First Affiliated Hospital of Fujian Medical University, 20 Chazhong Road, Fuzhou 350005 (China)

    2012-11-15

    Objective: The objective is to study the technology associated with and feasibility of the treatment of hepatocellular carcinoma (HCC) adjacent to large blood vessels using 1.5T MRI-guided radiofrequency ablation combined with iodine-125 (I-125) radioactive seed implantation. Methods: Sixteen patients with a total of 24 HCC lesions (average maximum diameter: 2.35 {+-} 1.03 cm) were pathologically confirmed by biopsy or clinically diagnosed received 1.5T MRI-guided percutaneous radiofrequency ablation (RFA) treatment. Each patient had one lesion adjacent to large blood vessels ({>=}3 mm); after the ablation, I-125 radioactive seeds were implanted in the portions of the lesions that were adjacent to the blood vessels. Results: All the ablations and I-125 radioactive seed implantations were successful; a total of 118 seeds were implanted. The ablated lesions exhibited hypointense signals on the T2WI sequence with a thin rim of hyperintense signals; they also exhibited significant hyperintense signals on the T1WI sequence with clear boundaries. The average follow-up period was 11.1 {+-} 6.2 months. There were 23 complete responses and one partial response in the 24 lesions. The alpha-fetoprotein (AFP) levels of the patients significantly decreased. Conclusion: The 1.5T MRI-guided RFA combined with I-125 radioactive seed implantation for the treatment of HCC adjacent to large blood vessels is an effective technology.

  11. The side effects and complications of percutaneous iodine-125 seeds implantation under CT-guide for patients with advanced pancreatic cancer.

    Science.gov (United States)

    Lv, Wei-Fu; Lu, Dong; Xiao, Jing-Kun; Mukhiya, Gauri; Tan, Zhong-Xiao; Cheng, De-Lei; Zhou, Chun-Ze; Zhang, Xing-Min; Zhang, Zheng-Feng; Hou, Chang-Long

    2017-12-01

    The present study investigates the side effects and complications of computed tomography (CT)-guided percutaneous iodine-125 (I-125) seeds implantation for advanced pancreatic cancer. The clinical data were retrospectively analyzed for patients treated with implantation of I-125 seeds under CT-guide in our hospital from May 2010 to April 2015. The side effects and complications were collected and their possible reasons were analyzed. A total of 78 patients were enrolled. The side effects were categorized as fever in 29 cases (37.18%), abdominal pain in 26 cases (33.33%), nausea and vomiting in 9 cases (11.54%), diarrhea in 5 cases (6.41%), and constipation in 4 cases (5.13%). Complications were composed of pancreatitis in 9 cases (11.54%), infection in 5 cases (6.41%), seed migration in 2 cases (2.56%), intestinal perforation in 1 case (1.28%), and intestinal obstruction in 1 case. The incidence of complication was 23.08% (18/78). The difference in incidence of complication was statistically significant between patients implanted with ≤27 seeds and those with >27 seeds (P = .032). The side effects and complications frequently occur in implantation of I-125 seeds for patients with advanced pancreatic cancer. More concern should be given to the patients treated by this technique. Copyright © 2017 The Authors. Published by Wolters Kluwer Health, Inc. All rights reserved.

  12. Dosimetric comparison of seed strength for I-125 prostate implants

    International Nuclear Information System (INIS)

    Elliott, S.; Droege, J.; Beaufort, C.

    2004-01-01

    Full text: The strength of 1-125 seeds for prostate brachytherapy has been a topic of increasing popularity in the literature over the last few years. Recent reports, which include planning and clinical studies, compare dosimetry between plans and implants using higher (0.5 - 0.8 U, where IU = I μGym 2 h -1 ) or lower (0.3 - 0.4 U) seed strength. The majority of these studies support higher seed strengths for obtaining optimal dosimetry. At the WBRC, a seed air kerma strength of just under 0.4 U is currently used for seed implants. The purpose of this work is to investigate the use of higher strength seeds for our prostate implants. Twenty-four patients were selected according to prostate size, and re-planned using a seed strength of 0.5 U or 0.6 U. Planning was performed following our standard preplanning guidelines as closely as possible; that is, manual planning using a modified Seattle approach and dosimetry limits for the target volume of D 100 : > 95 Gy, v 100 > 98 %, V 150 : 52 - 62 % and V 200 : 11 - 16 %. Dosimetry from the original preplans was then compared to the dosimetry from the re-planned cases. Satisfactory dosimetry was obtained using 0.5 U or 0.6 U strength seeds. Seed placement was typically around the periphery of the target on all slices, to avoid overdosing the urethra. The mean D 100 (Gy) is marginally improved with the higher seed strength. As expected, the V200 (%) is also higher. The mean number of seeds required per implant decreased by 16 % and 28 % for 0.5 U and 0.6 U seeds respectively. The mean number of needles decreased by 7 needles for 0.6 U seeds, however only by 3 needles for 0.5 U seeds. Rectal doses, when using the higher strength seeds, were easily constrained to less than the original preplan doses. Although there was no apparent trend in dosimetry statistics with volume size, as a function of seed strength, it was noted that the reduction in needle and seed number was most significant for medium and large target volumes. A

  13. Factors influencing upon the incidence of seed migration in I-125 seed transperineal prostate implantation

    International Nuclear Information System (INIS)

    Itami, Jun; Onishi, Kayoko; Kanemura, Mikio

    2005-01-01

    Transperineal I-125 seed brachytherapy for prostate cancer is rapidly expanding in Japan. Seed migrations to lung and abdomen are well known complication in the seed brachytherapy. The rate of incidence and the predisposing factors were studied. From April 2004 through January 2005, 36 patients underwent transperineal I-125 seed brachytherapy for prostate cancer. In all patients loose I-125 seeds were inserted with Mick applicator according to modified peripheral loading pattern. One day, 1 week, and 1 month after the procedure, posteroanterior and lateral chest X-rays and abdominal X-ray were performed. Abdominal and chest seed migrations were seen in 11 (30.6%) and 14 (38.9%) patients, respectively. In total, 20 patients (55.6%) showed seed migrations. Forty-two I-125 seeds migrated out of 2,508 implanted seeds. Most of the migrations were seen until 1 month after the procedure. The preplanned number of the extraprostatic seeds had a statistically significant influence upon the incidence of seed migration. Seed migration is not a rare phenomenon in transperineal I-125 seed brachytherapy for prostate cancer. To confirm seed migration, X-ray examinations 1 month after the procedure are suited. At the preplanning, the number of extraprostatic seeds should be limited to minimal to decrease the incidence of seed migration. In future, the introduction of linked I-125 seeds is preferred. (author)

  14. Half-life determination of 125I

    International Nuclear Information System (INIS)

    De Felice, P.; Ientile, P.; Zicari, C.

    1990-01-01

    The half-life of 125 I was determined by measuring the activity of an initial 3 kBq source at several times. Over a period of two months, 96 absolute measurements were performed, using the sum-peak method to give a half-life of (59.38±0.03) d. A discussion is presented on the effect of correcting for accidental coincidences on the half-life measurements by comparing the results with and without this correction. (orig.)

  15. The half-life of 125I

    International Nuclear Information System (INIS)

    Simpson, B.R.S.; Meyer, B.R.

    1989-01-01

    The Bureau International des Poids et Mesures (BIPM) organized an international comparison of activity measurements of a solution of 125 I. The half-life value adopted was 59.5±0.4d. The large uncertainty took account of a recently published value (Schrader, 1986) which is considerably lower than the widely used value of 60.0±0.1d. The present work, which was undertaken at the suggestion of the BIPM, has yielded a value which confirms the lower measurement. (author)

  16. Image fusion techniques in permanent seed implantation

    Directory of Open Access Journals (Sweden)

    Alfredo Polo

    2010-10-01

    image fusion for permanent seed implantation.

  17. Preparation of sup 125 I-creatine phosphokinase-MM

    Energy Technology Data Exchange (ETDEWEB)

    Jingxian, Su; Jingmin, Ma [Academia Sinica, Beijing, BJ (China). Inst. of Atomic Energy

    1988-09-01

    {sup 125}I-creatine phosphokinase-MM ({sup 125}I-CPK-MM) was prepared by {sup 125}I-labelled Bolton-Hunter reagent (HPNS). Iodinating conditions of HPNS and its conjugation to protein were studied. {sup 125}I-CPK-MM with immune activity was obtained and used to establish the {sup 125}I-CPK-MM radioimmunoassay method by the General Hospital of PLA. {sup 125}I-CPK-MM in PBS-G solution containing 0.015 mol/l ethyl mercaptan at 4-10 deg C can be used for one month.

  18. CT-guided {sup 125}I brachytherapy for mediastinal metastatic lymph nodes recurrence from esophageal carcinoma: Effectiveness and safety in 16 patients

    Energy Technology Data Exchange (ETDEWEB)

    Gao, Fei, E-mail: gaof@sysucc.org.cn [State Key Laboratory of Oncology in South China, Guangzhou 510060 (China); Department of Interventional Radiology, Sun Yat-sen University Cancer Center, 651 Dongfeng Road East, Guangzhou 510060 (China); Li, Chuanxing, E-mail: licx@sysucc.org.cn [State Key Laboratory of Oncology in South China, Guangzhou 510060 (China); Department of Interventional Radiology, Sun Yat-sen University Cancer Center, 651 Dongfeng Road East, Guangzhou 510060 (China); Gu, Yangkui, E-mail: guyk@sysucc.org.cn [State Key Laboratory of Oncology in South China, Guangzhou 510060 (China); Department of Interventional Radiology, Sun Yat-sen University Cancer Center, 651 Dongfeng Road East, Guangzhou 510060 (China); Huang, Jinhua, E-mail: huangjh@sysucc.org.cn [State Key Laboratory of Oncology in South China, Guangzhou 510060 (China); Department of Interventional Radiology, Sun Yat-sen University Cancer Center, 651 Dongfeng Road East, Guangzhou 510060 (China); Wu, Peihong, E-mail: vivian-link@163.com [State Key Laboratory of Oncology in South China, Guangzhou 510060 (China); Department of Interventional Radiology, Sun Yat-sen University Cancer Center, 651 Dongfeng Road East, Guangzhou 510060 (China)

    2013-02-15

    Objectives: To retrospectively evaluate effectiveness and safety of CT-guided {sup 125}I brachytherapy in 16 patients with mediastinal metastatic lymph nodes recurrence from esophageal carcinoma. Materials and methods: Sixteen metastatic lymph nodes in 16 patients were percutaneously treated in 19 {sup 125}I brachytherapy sessions. Each metastatic lymph node was treated with computed tomographic (CT) guidance. Follow-up contrast material-enhanced CT or positron emission tomographic (PET) scans were reviewed and the treatment's effectiveness was evaluated. Results: Months are counted from the first time of {sup 125}I brachytherapy and the median duration of follow-up was 11 months (range, 5–16 months). The local control rates after 3, 6, 10 and 15 months were 75.0, 50.0, 42.9 and 33.3% respectively. At the time of writing, four patients are alive without evidence of recurrence at 16, 9, 16 and 9 months. The 4 patients presented good control of local tumor and no systemic recurrence, and survived throughout the follow-up period. The other 12 patients died of multiple hematogenous metastases 5–15 months after brachytherapy. A small amount of local hematoma occurred in 2 patients that involved applicator insertion through the lung. Two patients presented pneumothorax with pulmonary compression of 30 and 40% after the procedure and recovered after drainage. One patient had minor displacement of radioactive seeds. Severe complications such as massive bleeding and radiation pneumonitis did not occur. Conclusion: {sup 125}I radioactive seed implantation is effective and may be safely applied to mediastinal metastatic lymph nodes recurrence from esophageal carcinoma.

  19. Decontamination of 125I in Medical Laboratory

    International Nuclear Information System (INIS)

    Abdel Geleel, M.; Tawfeek, A.A.

    2009-01-01

    A radiological laboratory for diagnoses was contaminated by 125 I. A large-scale survey of gamma-radiation has been made in different locations of the floors and walls of the lab to determine the contaminated area and its activity. The activity level before decontamination for the wall and floor was 1400 and 2000 Bq/cm 2 respectively. Decontamination was carried out by using ethyl alcohol, potassium permanganate, ethylene diamine tetracetic acid and tissue papers. Decontamination factor has been calculated and it was 175 and 200 for the wall and floor respectively. D and D computer code has been used to calculate Total Effective Dose Equivalent (TEDE). TEDE from the wall and floor before decontamination were 3.05 and 4.35 ( mSv/yr ) while after decontamination were 18 and 23μSv/yr respectively. These results are lower than the Egyptian and the international regulations (10 mSv/y for the public ) according to International Atomic Energy agency, IAEA, Safety Series, SS, no. 115 (1994).

  20. Optimization of 125I ophthalmic plaque brachytherapy

    International Nuclear Information System (INIS)

    Astrahan, M.A.; Luxton, G.; Jozsef, G.; Liggett, P.E.; Petrovich, Z.

    1990-01-01

    Episcleral plaques containing 125 I sources are often used in the treatment of ocular melanoma. Within four years post-treatment, however, the majority of patients experience some visual loss due to radiation retinopathy. The high incidence of late complications suggests that careful treatment optimization may lead to improved outcome. The goal of optimization would be to reduce the magnitude of vision-limiting complications without compromising tumor control. We have developed a three-dimensional computer model for ophthalmic plaque therapy which permits us to explore the potential of various optimization strategies. One simple strategy which shows promise is to maximize the ratio of dose to the tumor apex (T) compared to dose to the macula (M). By modifying the parameters of source location, activity distribution, source orientation, and shielding we find that the calculated T:M ratio can be varied by a factor of 2 for a common plaque design and posterior tumor location. Margins and dose to the tumor volume remain essentially unchanged

  1. Determination of radiochemical purity of 125I-TOC and 125I-F-PGA

    International Nuclear Information System (INIS)

    Yang Keya; Fan Wo; Zhang Youjiu; Xu Yujie; Zhu Ran; Hu Mingjiang

    2006-01-01

    To explore whether there is accordance among three determination methods of the radiochemical purity of [Tyr 3 ] octreotide (TOC) and folate-penicillin G amidase conjugate (F-PGA), which are both labeled with 125 I by Iodogen method, the RCP of the labelings are determined by high performance liquid chromatography (HPLC), paper chromatography and trichloroacetic acid (TCA) precipitation, in which four different concentrations of proteins are used to investigate the effect of them on the determination of RCP. It is shown that both HPLC and paper chromatography can separate the labelings from free iodine efficiently, though HPLC is the most precise and reliable method to determinate RCP of such labelings. In TCA precipitation, the RCP measured with 0.2%BSA is the lowest, but those with three other concentrations of the BSA are similar (P>0.05). When RCP 0.05), whereas higher than that with HPLC (P 10%, the RCP of 125 I-TOC obtained by TCA precipitation is a bit lower than those by two other methods (P 0.05), and there are no significant differences to determinate the RCP of 125 I-F-PGA (P>0.05). The three methods are correlated each other (r=0.0996-0.999, P<0.001). (authors)

  2. 125I eye plaque dose distribution including penumbra characteristics.

    Science.gov (United States)

    de la Zerda, A; Chiu-Tsao, S T; Lin, J; Boulay, L L; Kanna, I; Kim, J H; Tsao, H S

    1996-03-01

    The two main purposes of this work are (1) to determine the penumbra characteristics for 125I eye plaque and the relative influence of the plaque and eye-air interface on the dose distribution, and (2) to initiate development of a treatment planning algorithm for clinical dose calculations. Dose was measured in a newly designed solid water eye phantom for an 125I (6711) seed at the center of a 20 mm COMS eye plaque using thermoluminescent dosimeter (TLD) "cubes" and "minichips" inside and outside the eye, in the longitudinal and transverse central planes. TLD cubes were used in most locations, except for short distances from the seed and in the penumbra region. In the presence of both the plaque and the eye-air interface, the dose along the central axis was found to be reduced by 10% at 1 cm and up to 20% at 2.5 cm, relative to the bulk homogeneous phantom case. In addition, the overall dose reduction was greater for larger off-axis coordinates at a given depth. The penumbra characteristics due to the lip collimation were quantified, particularly the dependence of penumbra center and width on depth. Only small differences were observed between the profiles in the transverse and longitudinal planes. In the bulk geometry (without the eye-air interface), the dose reduction due to the presence of the plaque alone was found to be 7% at a depth of 2.5 cm. The additional reduction of 13% observed, with the presence of eye-air interface (20% combined), can be attributed to the lack of backscattering from the air in front of the eye. The dose-reduction effect due to the anterior air interface alone became unnoticeable at a depth of 1.1 cm (1.5 cm from the eye-air interface). An analytic fit to measured data was developed for clinical dose calculations for a centrally loaded seed. The central axis values of the dose rates multiplied by distance squared, Dr2, were fitted with a double exponential function of depth. The off-axis profile of Dr2, at a given depth, was

  3. Metabolism in the isolated rat heart: comparison of 125I-BMIPP with 125I-IPPA

    International Nuclear Information System (INIS)

    Chen Shaoliang; Cheng Aiping; Xu Lanwen; Qiao Weiwei

    2008-01-01

    Objective: The fatty acid metabolism in myocardium is recently one of the most interesting subjects in nuclear cardiology. The purpose of this study was to clarify the metabolic fate of 125 I-labeled 15-(p-iodophenyl)-3-(R, S)-methyl-pentadecanoic acid ( 125 I-BMIPP) and 15-(p-[ 125 I] iodophenyl) pentadecanoic acid ( 125 I-IPPA) by means of isolated rat hearts. Methods: Ten isolated rat hearts were prepared and perfused with 125 I-BMIPP (5 rats) or 125 I-IPPA (5 rats) for 3 h following a basic perfusion of 30 min. After perfusion, the radioactivity in the recirculated buffer was measured. The metabolites in the buffer were then extracted and analyzed using high performance liquid chromatography (HPLC) and thin-layer chromatography (TLC). Results: At the beginning (5 rain) of 125 I-BMIPP perfusion, the main radioactive peak appeared on HPLC at 37 min, which remained after 3 h perfusion. Several small peaks eluting were found before the parent peak at 30, 26, 21, 16, 12 and 9 min, respectively. At the beginning (5 min) of 125 I-IPPA perfusion, the main peak appeared on HPLC at 33 min, which disappeared after 3 h. Conclusions: 125 I-BMIPP strongly inhibited beta-oxidation, therefore appeared suitable for myocardial metabolic imaging. 125 I-IPPA was metabolized rapidly. (authors)

  4. Suggestions on technical guide of implantation of radioactive seeds

    International Nuclear Information System (INIS)

    Wang Zhongmin; Huang Gang; Lv Zhongwei; Liu Jianjun; Chen Kemin; Chen Yongde

    2009-01-01

    Implantation of radioactive seeds is an effective therapeutic option for the treatment of malignant tumors. With the development of imaging technique and the use of treatment planning system (TPS) it has been more and more employed in clinical settings. The technique has been widely practiced in various malignant tumors, such as prostate cancer, lung caner, pancreatic cancer, hepatocarcinoma, etc. In order to standardize the clinical application of this technology, the authors propose some suggestions concerning the management of radioactive seeds, the indications and contraindications as well as the method of operation as a technical guidance. (authors)

  5. Suggestions on technical guide of implantation of radioactive seeds

    Energy Technology Data Exchange (ETDEWEB)

    Zhongmin, Wang; Gang, Huang; Zhongwei, Lv; Jianjun, Liu [Department of Radiology, Luwan Branch of Ruijin Hospital, School of Medicine, Shanghai Jiaotong Univ., Shanghai (China); Kemin, Chen; Yongde, Chen

    2009-09-15

    Implantation of radioactive seeds is an effective therapeutic option for the treatment of malignant tumors. With the development of imaging technique and the use of treatment planning system (TPS) it has been more and more employed in clinical settings. The technique has been widely practiced in various malignant tumors, such as prostate cancer, lung caner, pancreatic cancer, hepatocarcinoma, etc. In order to standardize the clinical application of this technology, the authors propose some suggestions concerning the management of radioactive seeds, the indications and contraindications as well as the method of operation as a technical guidance. (authors)

  6. Synthesis and binding of [125I2]philanthotoxin-343, [125I2]philanthotoxin-343-lysine, and [125I2]philanthotoxin-343-arginine to rat brain membranes

    International Nuclear Information System (INIS)

    Goodnow, R.A. Jr.; Bukownik, R.; Nakanishi, K.; Usherwood, P.N.; Eldefrawi, A.T.; Anis, N.A.; Eldefrawi, M.E.

    1991-01-01

    125I2-iodinated philanthotoxin-343 (PhTX-343), [125I2]PhTX-343-arginine, and [125I2]PhTX-343-lysine were synthesized and evaluated as probes for glutamate receptors in rat brain synaptic membranes. It was found that these probes were not specific for the glutamate receptors but may be useful for investigating the polyamine binding site. Filtration assays with Whatman GF/B fiber glass filters were unsuitable because the iodinated PhTX-343 analogues exhibited high nonspecific binding to the filters, thus hindering detection of specific binding to membranes. When binding was measured by a centrifugal assay, [125I2]PhTX-343-lysine bound with low affinity (KD = 11.4 ± 2 microM) to a large number of sites (37.2 ± 9.1 nmol/mg of protein). The binding of [125I2]PhTX-343-lysine was sensitive only to the polyamines spermine and spermidine, which displaced [125I2]PhTX-343-lysine with Ki values of (3.77 ± 1.4) x 10(-5) M and (7.51 ± 0.77) x 10(-5) M, respectively. The binding was insensitive to glutamate receptor agonists and antagonists. Binding results with [125I2]PhTX-343-arginine were similar to those of [125I2]-PhTX-343-lysine. Considering the high number of toxin binding sites (10000-fold more than glutamate) in these membranes and the insensitivity of the binding to almost all drugs that bind to glutamate receptors, it is evident that most of the binding observed is not to glutamate receptors. On the other hand, PhTX analogues with photoaffinity labels may be useful in the isolation/purification of various glutamate and nicotinic acetylcholine receptors; they could also be useful in structural studies of receptors and their binding sites

  7. Feasibility and clinical value of CT-guided {sup 125}I brachytherapy for metastatic soft tissue sarcoma after first-line chemotherapy failure

    Energy Technology Data Exchange (ETDEWEB)

    Mo, Zhiqiang; Zhang, Yanling; Xiang, Zhanwang; Yan, Huzhen; Zhong, Zhihui; Gao, Fei; Zhang, Fujun [Sun Yat-Sen University Cancer Centre, State Key Laboratory of Oncology in South China, Collaborative Innovation Centre for Cancer Medicine, Guangzhou (China); Zhang, Tao [Guangzhou Medical University, Department of Interventional Radiology and Vascular Anomalies, Guangzhou Women and Children' s Medical Centre, Guangzhou (China)

    2018-03-15

    To evaluate the feasibility and usefulness of computed tomography (CT)-guided iodine{sup 125} ({sup 125}I) brachytherapy for patients with metastatic soft tissue sarcoma (STS) after first-line chemotherapy failure. We recruited 93 patients with metastatic STS who had received first-line chemotherapy 4-6 times but developed progressive disease, from January 2010 to July 2015; 45 patients who had combined {sup 125}I brachytherapy and second-line chemotherapy (Group A), and 48 patients who received second-line CT only (Group B). In Group A, 49 {sup 125}I seed implantation procedures were performed in 45 patients with 116 metastatic lesions; the primary success rate was 91.1% (41/45), without life-threatening complications. Local control rates at 3, 6, 12, 24 and 36 months were 71.1%, 62.2%, 46.7%, 28.9% and 11.1% for Group A, and 72.9%, 54.2%, 18.8%, 6.3% and 0% for Group B. Mean progression-free survival differed significantly (Group A: 7.1±1.3 months; Group B: 3.6 ±1.1 months; P<0.001; Cox proportional hazards regression analysis), but overall survival did not significantly differ (Group A: 16.9 ±5.1 months; Group B: 12.1 ± 4.8 months). Group A showed better symptom relief and quality of life than Group B. CT-guided {sup 125}I brachytherapy is a feasible and valuable treatment for patients with metastatic STS. (orig.)

  8. Fragmentation of chromatin with 125I radioactive disintegrations

    International Nuclear Information System (INIS)

    Turner, G.N.; Nobis, P.; Dewey, W.C.

    1976-01-01

    The DNA in Chinese hamster cells was labeled first for 3 h with [ 3 H]TdR and then for 3 h with [ 125 I]UdR. Chromatin was extracted, frozen, and stored at -30 0 C until 1.0 x 10 17 and 1.25 x 10 17 disintegrations/g of labeled DNA occurred for 125 I and 3 H, respectively. Velocity sedimentation of chromatin (DNA with associated chromosomal proteins) in neutral sucrose gradients indicated that the localized energy from the 125 I disintegrations, which gave about 1 double-strand break/disintegration plus an additional 1.3 single strand breaks, selectively fragmented the [ 125 I] chromatin into pieces smaller than the [ 3 H] chromatin. In other words, 125 I disintegrations caused much more localized damage in the chromatin labeled with 125 I than in the chromatin labeled with 3 H, and fragments induced in DNA by 125 I disintegrations were not held together by the associated chromosomal proteins. Use of this 125 I technique for studying chromosomal proteins associated with different regions in the cellular DNA is discussed. For these studies, the number of disintegrations required for fragmenting DNA molecules of different sizes is illustrated

  9. Quality asurance of iodinated (125 I) human fibrinogen

    International Nuclear Information System (INIS)

    Vines, E.J.

    1980-05-01

    The radiopharmaceutical iodinated ( 125 I) human fibrinogen is currently used for the detection of deep vein thrombosis in the legs, a fairly common post-surgical complication. A comprehensive quality assurance programme for ( 125 I) - human fibrinogen has been determined for routine use at the Australian Radiation Laboratory, with adaptions necessary for hospital quality control testing

  10. Immunoreactivity of 125I-papain labelled by different methods

    International Nuclear Information System (INIS)

    Rauch, P.; Fukal, L.; Kas, J.; Tykva, R.

    1984-01-01

    Three different methods of papain iodination (with chloramine-T, lactoperoxidase and conjugation with Bolton-Hunter reagent) have been compared. The highest yield of 125 I-papain could be obtained using lactoperoxidase which enabled to achieve the highest immunoreactivity. 125 I-papain, labelled this way, is suitable for the radioimmunoassay of papain. (author)

  11. Preparation and evaluation of serotonin labelled with 125I

    International Nuclear Information System (INIS)

    Sivaprasad, N.; Geetha, R.; Ghodke, A.S.; Karmalkar, C.P.; Pilkhwal, N.S.; Sarnaik, J.S.; Borkute, S.D.; Nadkarni, G.D.

    1999-01-01

    Radiolabelled serotonin is an important tool for studying serotonin receptors and estimating serotonin levels in plants and animals. In this paper we report the synthesis of serotonin - 125 I. Tyrosine Methyl Ester (TME) was first labelled with 125 I using chloramine-T method. 125 I-TME was then conjugated with serotonin using carbodimide. The labelled conjugate was purified using gel filtration. Yield and radiochemical purity were estimated using electrophoresis and ITLC in different solvent systems. The binding of the purified tracer to serotonin receptors and serotonin antibodies was studied. (author)

  12. Radiobiologically based treatment plan evaluation for prostate seed implants

    Directory of Open Access Journals (Sweden)

    Sotirios Stathakis

    2011-07-01

    Full Text Available Purpose: Accurate prostate low dose-rate brachytherapy treatment plan evaluation is important for future care decisions. Presently, an evaluation is based on dosimetric quantifiers for the tumor and organs at risk. However, these do not account for effects of varying dose-rate, tumor repopulation and other biological effects. In this work, incorporation of the biological response is used to obtain more clinically relevant treatment plan evaluation.Material and methods: Eleven patients were evaluated. Each patient received a 145 Gy implant. Iodine-125 seeds were used and the treatment plans were created on the Prowess system. Based on CT images the post-implant plan was created. In the post-plan, the tumor, urethra, bladder and rectum were contoured. The biologically effective dose was used to determine the tumor control probability and the normal tissue complication probabilities for the urethra, bladder, rectum and surrounding tissue. Results: The average tumor control probability and complication probabilities for the urethra, bladder, rectum and surrounding tissue were 99%, 29%, 0%, 12% and 6%, respectively. These measures provide a simpler means for evaluation and since they include radiobiological factors, they provide more reliable estimation of the treatment outcome. Conclusions: The goal of this work was to create more clinically relevant prostate seed-implant evaluation by incorporating radiobiological measures. This resulted in a simpler descriptor of treatment plan quality and was consistent with patient outcomes.

  13. A novel curvilinear approach for prostate seed implantation

    Energy Technology Data Exchange (ETDEWEB)

    Podder, Tarun K.; Dicker, Adam P.; Hutapea, Parsaoran; Darvish, Kurosh; Yu Yan [Department of Radiation Oncology, Leo Jenkins Cancer Center, Brody School of Medicine, East Carolina University, Greenville, North Carolina 27834 (United States); Department of Radiation Oncology, Kimmel Cancer Center, Jefferson Medical College, Thomas Jefferson University, Philadelphia, Pennsylvania 19107 (United States); Department of Mechanical Engineering, Temple University, Philadelphia, Pennsylvania 19122 (United States); Department of Radiation Oncology, Kimmel Cancer Center, Jefferson Medical College, Thomas Jefferson University, Philadelphia, Pennsylvania 19107 (United States)

    2012-04-15

    Purpose: A new technique called ''curvilinear approach'' for prostate seed implantation has been proposed. The purpose of this study is to evaluate the dosimetric benefit of curvilinear distribution of seeds for low-dose-rate (LDR) prostate brachytherapy. Methods: Twenty LDR prostate brachytherapy cases planned intraoperatively with VariSeed planning system and I-125 seeds were randomly selected as reference rectilinear cases. All the cases were replanned by using curved-needle approach keeping the same individual source strength and the volume receiving 100% of prescribed dose 145 Gy (V{sub 100}). Parameters such as number of needles, seeds, and the dose coverage of the prostate (D{sub 90}, V{sub 150}, V{sub 200}), urethra (D{sub 30}, D{sub 10}) and rectum (D{sub 5}, V{sub 100}) were compared for the rectilinear and the curvilinear methods. Statistical significance was assessed using two-tailed student's t-test. Results: Reduction of the required number of needles and seeds in curvilinear method were 30.5% (p < 0.001) and 11.8% (p < 0.49), respectively. Dose to the urethra was reduced significantly; D{sub 30} reduced by 10.1% (p < 0.01) and D{sub 10} reduced by 9.9% (p < 0.02). Reduction in rectum dose D{sub 5} was 18.5% (p < 0.03) and V{sub 100} was also reduced from 0.93 cc in rectilinear to 0.21 cc in curvilinear (p < 0.001). Also the V{sub 150} and V{sub 200} coverage of prostate reduced by 18.8% (p < 0.01) and 33.9% (p < 0.001), respectively. Conclusions: Significant improvement in the relevant dosimetric parameters was observed in curvilinear needle approach. Prostate dose homogeneity (V{sub 150}, V{sub 200}) improved while urethral dose was reduced, which might potentially result in better treatment outcome. Reduction in rectal dose could potentially reduce rectal toxicity and complications. Reduction in number of needles would minimize edema and thereby could improve postimplant urinary incontinence. This study indicates that the

  14. Dosimetry consequences of the accuracy at the position of the seeds in a seeds implant of I-125 in prostate

    International Nuclear Information System (INIS)

    Luquero Llopis, N.; Ferrer Gracia, C.; Huertas Martinez, C.; Huerga Cabrerizo, C.; Corredoira Silva, E.; Serrada Hierro, A.

    2013-01-01

    The quality control of equipment used to carry out implants of seeds of low rate in prostate, van destined to watch, the activity of seeds and the calculation of planning both positioning them on the inside of the patient. The objective of this work is, using the Nucletron Spot Pro and SeedSelectron, rating dosimetry possible consequences related to the position of the seeds. (Author)

  15. Pulmonary embolization of permanently implanted radioactive palladium-103 seeds for carcinoma of the prostate

    International Nuclear Information System (INIS)

    Nag, Subir; Vivekanandam, Singhavajhala; Martinez-Monge, Rafael

    1997-01-01

    Purpose: It has been reported that permanently implanted iodine-125 seeds can embolize to the lungs. There is little data on the embolization of palladium-103 seeds. The purpose of this study is to collect and evaluate data on the embolization of Pd-103 seeds. Methods and Materials: The records of 112 patients implanted with Pd-103 for carcinoma of the prostate were reviewed to systemically study the incidence and dynamics of pulmonary embolism of Pd-103 seeds. Five patients had no postoperative chest radiograph and were thus excluded, leaving 107 patients for review. Results: Chest radiographs of 19 of the 107 patients showed embolized seeds in the lungs (18%). Two patients had three seeds each, nine patients had two seeds each; and in the remaining eight patients, a single seed migrated to the lungs. The seeds migrated mainly (84%) to the lower lobes. None of the eight patients who had their first postoperative chest radiograph on the day of the implant showed any embolized seeds. The embolized seed appeared only on subsequent chest radiographs taken 27 to 40 days later. Ten of the other 11 patients who had their first radiograph 1 to 97 days after brachytherapy had embolized seeds on their first chest radiograph. In the other patient, the embolized seed appeared only on a subsequent chest radiograph taken after 127 days. There were no clinical pulmonary or cardiac effects evident on routine follow-up of these patients with pulmonary embolized seeds. Conclusion: Embolization of Pd-103 seeds to the lungs after implantation for carcinoma of the prostate is an unusual event. In this study only 0.3% of the seeds implanted migrated to the lungs. Although it was previously thought that pulmonary seed migration mainly occurred on the day of brachytherapy, our experience shows that seeds usually migrated to the lungs after the day of the implant. There were no clinical pulmonary or cardiac effects attributable to embolized seeds in the lungs on routine follow-up

  16. Detection Limits Of The 125I Air Sampler ''RIS125''

    International Nuclear Information System (INIS)

    Belaish, I.; Levinson, S.; German, U.; Kravchik, T.

    1999-01-01

    A system for 125 I monitoring in air (RIS-125) was designed and manufactured at NRCN. The main features of the system are described elsewhere. The system can monitor 125 I air contamination in gaseous and aerosol forms. An air monitoring system should have a fast response and the lowest available Minimum Detectable Activity (MDA). The present work presents the characteristic MDA values of the system

  17. A comparative study of 19-iodocholesterol-''125I 3-acetate and Na''125I in liquid scintillation measurements

    International Nuclear Information System (INIS)

    Rodriguez Barquero, L.; Grau Malonda, A.; Los Arcos Merino, J.M.; Grau Carles, A.

    1994-01-01

    A comparative study of performance of 19-iodocholesterol-''125I 3-acetate and sodium iodine samples labelled with ''125 I is presented for liquid scintillation counting measurements. Quench effect, count rate stability and spectral evolution of samples have been followed for several weeks in Toluene, Hisafe II, Instagel, Dioxane-naphthalene and Toluene-alcohol scintillators. Organic samples have negligible quench effect in the interval of I''-concentration of 0-90 ug and inorganic samples only show a very small variation, lower than 12%, for Dioxane-naphthalene, in the same range of concentration. Satisfactory stability is obtained in general for both, organic and inorganic samples, but small counting losses, 0.03% for 19-iodocholesterol-''125I 3-acetate samples in Toluene-alcohol and 0.04% for Na''125I samples in Dioxane-naphthalene and Toluene-alcohol, have been reported. (Author) 8 refs

  18. Spectroscopic output of {sup 125}I and {sup 103}Pd low dose rate brachytherapy sources

    Energy Technology Data Exchange (ETDEWEB)

    Usher-Moga, Jacqueline; Beach, Stephen M.; DeWerd, Larry A. [Department of Medical Physics, University of Wisconsin--Madison, Madison, Wisconsin 53705 (United States); Global Physics Solutions, St. Joseph, Michigan 49085 (United States); Department of Medical Physics, University of Wisconsin-Madison, Madison, Wisconsin 53705 (United States)

    2009-01-15

    The spectroscopic output of low dose rate (LDR) brachytherapy sources is dependent on the physical design and construction of the source. Characterization of the emitted photons from 12 {sup 125}I and 3 {sup 103}Pd LDR brachytherapy source models is presented. Photon spectra, both along the transverse bisector and at several polar angles, were measured in air with a high-purity reverse electrode germanium (REGe) detector. Measured spectra were corrected to in vacuo conditions via Monte Carlo and analytical methods. The tabulated and plotted spectroscopic data provide a more complete understanding of each source model's output characteristics than can be obtained with other measurement techniques. The variation in fluorescence yield of the {sup 125}I sources containing silver caused greater differences in the emitted spectra and average energies among these seed models than was observed for the {sup 103}Pd sources or the {sup 125}I sources that do not contain silver. Angular spectroscopic data further highlighted the effects of source construction unique to each model, as well as the asymmetric output of many seeds. These data demonstrate the need for the incorporation of such physically measured output characteristics in the Monte Carlo modeling process.

  19. Theoretical analysis of microdosimetric spectra and cluster formation for 103Pd and 125I photon emitters

    International Nuclear Information System (INIS)

    Reniers, B; Vynckier, S; Verhaegen, F

    2004-01-01

    In this work we have compared 125 I or 103 Pd from a microdosimetric point of view. The photon spectra at different positions around the seeds have first been calculated using EGSnrc Monte Carlo (MC) code. These photon spectra are used as input for the event-by-event MC code TRION to calculate the microdosimetric lineal energy (y) distribution for each isotope. The microdosimetric dose average lineal energy, y D , calculated in a sphere of 1 μm is 3.5 keV μm -1 for 125 I and 4.0 keV μm -1 for 103 Pd, agreeing well with values reported in the literature. y D in a 1 μm sphere diminishes slightly with the distance from the seed for 103 Pd. This is due to the spectral hardening caused by the presence of a gamma-ray of 357.5 keV in the initial spectrum of 103 Pd. In parallel with the calculation of the microdosimetric spectra, we have analysed the distribution of the size of the energy deposition clusters generated by these low energy photons in structures of 2 and 10 nm of radius. Due to Compton interactions, the fraction of very low energy electrons ( 125 I photons is 51%, whereas it is only 27% for 103 Pd. As these electrons deposit their energy very locally, the pattern of energy depositions contains more clusters of a few nm of radius for 125 I than for 103 Pd; the mean cluster orders are respectively 3.3 and 3.0 for 10 nm clusters. This is in opposition with the prediction based on the microdosimetric spectrum and the parameter y D and could be of importance for the damage to the cells

  20. 125I-β-CIT biodistribution study in animals

    International Nuclear Information System (INIS)

    Hu Ping

    2000-01-01

    The purpose is to study the preparation and biodistribution in animal of dopamine transporter imaging agent 125 I-β-CIT. β-CIT was 125 I radioiodinated with Iodogen method, the dynamic distribution of 125 I-β-CIT in brain and critical organs were studied with SD rat (autoradiography) and NIH mice respectively. The radiolabelling yield of 125 I-β-CIT was 84%, the radiochemical purity was better than 98%. Blood clearance could be explained by two-compartment model with a duration of 12h, (α = 3.87, T 1/2α = 0.179, β = 0.162, T 1/2β = 4.276) and three-compartment model in 24 h, (Pi = 5.28, T 1/2Pi = 0.131, α = 0.403, T 1/2α = 1.719, β 0.040, T 1/2β = 17.298). The maxim uptake rate of brain (9.1% +- 1.0%) was reaches at 1h, while at 24h, the target/noise ratio was higher . Critical organs liver, lung, spleen and kidney had high uptake rate [(9.88 +- 1.43) - (16.29 +- 1.72)], except liver, other organs showed quick clearance (T 1/2 125 I-β-CIT has a high striatum uptake and good stability in vivo, can provide good SPECT images, the best acquisition time of SPECT may be about 20h after i.v

  1. Cytotoxicity of an 125I-labelled DNA ligand

    International Nuclear Information System (INIS)

    Karagiannis, T.C.; Lobachevsky, P.N.; Martin, R.F.

    2000-01-01

    The subcellular distribution and cytotoxicity of a DNA-binding ligand [ 125 I]-Hoechst 33258 following incubation of K562 cells with the drug was investigated. The ability of a radical scavenger, dimethyl sulphoxide, to protect cells from the 125 I-decay induced cell death was also studied. Three different concentrations and specific activities of the drug were used to provide different ligand : DNA binding ratios. The results demonstrated a trend toward improved delivery of the ligand to the nucleus and to chromatin at higher ligand concentrations, with concomitant increased sensitivity to 125 I-decay induced cytotoxicity and decreased protection by dimethyl sulphoxide. This correlation of radiobiological parameters with subcellular drug distribution is consistent with the classical dogma that attributes cytotoxicity to DNA double-stranded breakage in the vicinity of the site of decay, where the high LET nature of the damage confers minimal sensitivity to radical scavenging

  2. Effect of organic matter on 125I diffusion in bentonite

    International Nuclear Information System (INIS)

    Tao Wu; Qing Zheng

    2015-01-01

    Through-diffusion method was conducted to investigate the diffusion behavior of 125 I in bentonite in present of organic matter, such as polyaminopolycarboxylate EDTA, oxalic acid, hydrazine and humic acid HA. The effective diffusion coefficient D e value and rock capacity factor α were (2.32.6) × 10 -11 m 2 /s and 0.040-0.052, respectively. The small difference showed that iodine was preferentially associated with silicoaluminate mineral as an inorganic form. In present of HA, the D a value of 125 I was almost two orders of magnitude higher than that of HA and humic substances HS. The D e and α derived from the experiments were used to simulate its diffusion in the designed bentonite obstacle of high-level radioactive waste repository and the results showed that 125 I can be transported from 30 to 50 cm thickness of bentonite to the far-field of repository in several years. (author)

  3. Dose rate effect of 125I irradiation on normal rabbit eyes and experimental choroidal melanoma

    International Nuclear Information System (INIS)

    Yang, C.M.; Olsen, K.R.; Schwade, J.G.; Houdek, P.V.; Markoe, A.M.; Pisciotta, V.; Xiaodong Wu

    1993-01-01

    The dose rate effect of radiation by 125 I plaque on choroidal melanoma and normal intraocular tissue was studied. In the first part of the experiment, high activity plaques (HAP) and low activity plagues (LAP) were implanted on rabbit eyes with experimental Greene choroidal melanoma to deliver a total dose of 10 000 cGy to the tumor apex. The mean dose rate calculated at 0.5 mm from the inner sclera in eight eyes with high activity plaques was 3341.5 cGy hr -1 while that in ten eyes with low activity plaques was 239.9 cGy hr -1 . For tumors less than 1.0 mm in height, both groups showed complete tumor regression at the tumor implantation site after plaque treatment. For tumours more than 1.0 mm in height, two out of two eyes in the low activity plaque group and one of four eyes in the high activity plaque group failed to show complete tumor regression. In the second part of the experiment, 125 I plaques were implanted on the sclera of 12 normal rabbits' eyes. Six received high dose rate plaque treatment, while the other six received low dose rate plaque treatment. Clinical and histologic examinations demonstrated more damaging effects to the normal chorioretinal tissues at the plaque implantation site in the high dose rate plaque group. These results suggest that high dose rate plaques are more effective than low dose rate plaques when tumor height is statistically controlled. (Author)

  4. Loss of I-125 seeds after perineal implantation of the prostate

    International Nuclear Information System (INIS)

    Wopereis, A.J.M.; Moerland, M.A.; Koning, J.H.A.G. de; Battermann, J.J.

    1996-01-01

    Introduction: One of the treatment modalities of early stage prostate cancer is the permanent implantation of I-125 seeds. The aim of this study was to obtain insight in the loss of seeds after implantation. Methods and Materials: During the past 6 years, 100 patients were treated and examined. Radiographs of the prostate area were taken at discharge (after 2 or 3 days) and combined with a follow-up appointment, successively after 1, 3, 6, 12 and 24 months. 10 patients were excluded from this study because of a later performed prostatectomy or TURP. During the hospitalisation period the patient's excrements were examined for lost seeds. Furthermore patients were instructed to urinate through a tea-strainer in the first month following implantation in order to prevent seeds from entering the sewage system. Results: We observed an overall loss of 5% during the entire follow-up period of 2 years. Further analysis of the obtained data showed that most of the seeds (3% of the implanted seeds) were lost in the first 2 days after implantation. Due to special attention paid to safety measures, 94% of the lost seeds were retrieved during the admission period. Because of adequate instructions given to the patients, 70% of the seeds lost during the first month after discharge (0.5% of the total number of remaining implanted seeds) were also retrieved. Losing seeds during the first month after implantation did not increase the chance of further loss later on. A total of 13 seeds (in all patients) was lost after 1 month (of which 6 were lost after more then one year and are for radiation safety reasons not of importance). Conclusions: Most seeds are lost during the first days after implantation. Therefore, radiographs are indicated at discharge, after 1 month (for evaluation of safety precautions) and after 1 year as a conclusion to the treatment

  5. Study of CT-guided iodine-125 implantation in the treatment of rabbit VX2 tumor

    International Nuclear Information System (INIS)

    He Kewu; Gao Bin; Li Jiajia

    2008-01-01

    Objective: To evaluate the effect of CT-guided iodine-125 seed( 125 I) implantation to rabbit model VX2 tumor cell apoptosis. Methods: VX2 tumor cells were implanted into muscle of 40 rabbits legs, 3 weeks later, as the diameter of tumor reached 2 cm available for test. Randomly selected the sampling tumor on one leg of rabbit as for the test team and tumor on the contralateral leg as for control team. Under CT guidance, 125 I seeds were implanted into 20 tumor lesions of the test team, and hollow seeds were implanted into 20 tumor lesions of the control team. Instantly, 72 h, 1, 2, 3 w after operation, percutaneous tumor tissue sampling was done 0.5-1.0 cm and 1.0-1.5 cm away from seed implanted site under CT guidance; and apoptosis was investigated by FCM. Results: Instantly, 72 h, 1, 2, 3 w after treatment with iodine-125 ( 125 I) implantation, the tissue sampling away from seed 0.5-1.0 cm showed the apoptosis rates of control team and test team were respectively as follows: (5.43±0.67)% and (5.48±0.66)%, (P>0.05), (5.45±0.58)% and (11.60±0.87)%, (P O.05)of the control team and test team. Conclusions: 125 I seeds implantation can induce tumor cell apoptosis, beginning at 72 h and reached peak at 2 w and kept the high level here afterword. The apoptosis rate descended rapidly along with the increase of distance away from the 125 I seedling. (authors)

  6. SU-F-T-39: Comparing Nomograms for Ordering of Palladium-103 Seeds for Dynamic Intraoperative Prostate Seed Implantation

    Energy Technology Data Exchange (ETDEWEB)

    Taylor, P; Wang, L; Riegel, A [Northwell Health, Lake Success, NY (United States)

    2016-06-15

    Purpose: Several nomograms exist for the purpose of ordering palladium- 103 seeds for permanent prostate seed implants. Excess seeds pose additional radiation safety risks and increase the cost of care. This study compared three seed ordering nomograms with seed counts from dynamic intra-operative PSI to determine (1) the cause of excess seeds and (2) the optimal nomogram for our institution. Methods: Pre-operative and intra-operative clinical data were collected for 100 Gy (n=151) and 125 Gy (n=224) prostate seed implants. The number of implanted seeds which would have given D90=100% was normalized to that criteria and seed strength of 2U. This was plotted against intra-operative prostate volume and compared to two previously published nomograms and an in-house nomogram. A linear fit was produced and confidence intervals were calculated. The causes of excess seeds were assessed by comparing pre- and intra-operative prostate volumes, variability of D90 around 100%, and variance of seed strength from 2U. Results: Of the 375 total cases, 97.6% had excess seeds. On average, 27.17±12.91% of ordered seeds were wasted. Of this percentage, 6.98±5.47% of excess seeds were due to overestimation of pre-operative prostate volume, 1.10±0.88% were due to D90<100%, 1.17±0.67% were due to seed strength over 2U, and 17.36±7.79% could not be directly attributed to a specific reason. The latter percentage may be due to overestimation of the in-house nomogram. Two of three nomograms substantially overestimated the number of seeds required. The third nomogram underestimated the required seed number for smaller prostate treatment volume. A linear fit to the clinical data was derived and 99.9% confidence intervals were calculated. Conclusion: Over 85% of clinical cases wasted over 15% of ordered seeds. Two of three nomograms overestimated the required number of seeds. The upper 99.9% C.I. of the clinical data may provide a more reasonable nomogram for Pd-103 seed ordering.

  7. SU-F-T-39: Comparing Nomograms for Ordering of Palladium-103 Seeds for Dynamic Intraoperative Prostate Seed Implantation

    International Nuclear Information System (INIS)

    Taylor, P; Wang, L; Riegel, A

    2016-01-01

    Purpose: Several nomograms exist for the purpose of ordering palladium- 103 seeds for permanent prostate seed implants. Excess seeds pose additional radiation safety risks and increase the cost of care. This study compared three seed ordering nomograms with seed counts from dynamic intra-operative PSI to determine (1) the cause of excess seeds and (2) the optimal nomogram for our institution. Methods: Pre-operative and intra-operative clinical data were collected for 100 Gy (n=151) and 125 Gy (n=224) prostate seed implants. The number of implanted seeds which would have given D90=100% was normalized to that criteria and seed strength of 2U. This was plotted against intra-operative prostate volume and compared to two previously published nomograms and an in-house nomogram. A linear fit was produced and confidence intervals were calculated. The causes of excess seeds were assessed by comparing pre- and intra-operative prostate volumes, variability of D90 around 100%, and variance of seed strength from 2U. Results: Of the 375 total cases, 97.6% had excess seeds. On average, 27.17±12.91% of ordered seeds were wasted. Of this percentage, 6.98±5.47% of excess seeds were due to overestimation of pre-operative prostate volume, 1.10±0.88% were due to D90<100%, 1.17±0.67% were due to seed strength over 2U, and 17.36±7.79% could not be directly attributed to a specific reason. The latter percentage may be due to overestimation of the in-house nomogram. Two of three nomograms substantially overestimated the number of seeds required. The third nomogram underestimated the required seed number for smaller prostate treatment volume. A linear fit to the clinical data was derived and 99.9% confidence intervals were calculated. Conclusion: Over 85% of clinical cases wasted over 15% of ordered seeds. Two of three nomograms overestimated the required number of seeds. The upper 99.9% C.I. of the clinical data may provide a more reasonable nomogram for Pd-103 seed ordering.

  8. Beta-decay 125I → 125Te

    Directory of Open Access Journals (Sweden)

    A. A. Kurteva

    2016-08-01

    Full Text Available Beta-decay of the nucleus 125I and spectroscopic characteristics of the daughter nucleus are described within the framework of the dynamic collective model. Quasiparticle and multiphonon states, as well as vacuum fluctuations of quasiparticles are taken into account. The comparison of the results of calculations with the available experimental data is performed.

  9. Preclinical pharmacological study on 125 I-IPPA

    International Nuclear Information System (INIS)

    Wu Chunying; Ji Shuren; Fang Ping; Zhou Xiang; He Yongjun; Cao Guoxian

    1999-01-01

    Myocardial uptake of 125 I-IPPA in rats showed a peak of 4.4% of injected dose per gram. The half elimination time of myocardium was 3.8 min and the maximal uptake of thyroid is only 0.005%ID/organ at 120 min. The initial half time of 2.7 min in rabbits was obtained from the elimination curve of radioactivity in blood. In vitro binding test for 125 I-IPPA to HSA showed rather constant level of activation during tow hours. The second peak of extraction was observed in major organs of rats, in rabbits' elimination of radioactivity and in binding test for 125 I-IPPA to albumin in vivo. Toxicity trial was up to standard. The tolerance of a mouse to IPPA was 560 times as high as that of a person to IPPA. It demonstrated that 125 I-IPPA could be quickly extracted by myocardium, and its catabolite were excreted in the urine with almost no iodine loss. All the results were found to agree with the expectations based on the principal metabolic path of phenyl fatty acid

  10. In Vivo Thyroid 125I Monitoring with Radioluminography

    International Nuclear Information System (INIS)

    Nishizawa, K.; Saze, T.; Yamashita, H.; Etoh, M.

    1999-01-01

    The counting features of an in vivo thyroid monitoring system with an imaging plate (IP) were investigated by using an anthropomorphic thyroid-neck phantom. The realistic thyroid phantoms loaded with 125 I solution were embedded in a neck phantom. The IP was fixed on the neck phantom and exposed to 125 I photons emitted from the thyroid phantom by changing the pre-thyroid tissue thickness at the front of the thyroid. A clear thyroid image was obtained at short tissue thicknesses. A region of interest (ROI) was set so that the ROI contained the thyroid image. The count within the ROI was regarded as the number of 125 I photons detected by the IP. The IP counting efficiency was about 0.6% at maximum. Monitoring with IP has the advantage of allowing the worker to move freely during the monitoring period by wearing the IP on his neck. Radioluminography with IP has shown itself to be useful when monitoring thyroid 125 I. (author)

  11. Towards clinical application of RayStretch for heterogeneity corrections in LDR permanent 125I prostate brachytherapy.

    Science.gov (United States)

    Hueso-González, Fernando; Ballester, Facundo; Perez-Calatayud, Jose; Siebert, Frank-André; Vijande, Javier

    RayStretch is a simple algorithm proposed for heterogeneity corrections in low-dose-rate brachytherapy. It is built on top of TG-43 consensus data, and it has been validated with Monte Carlo (MC) simulations. In this study, we take a real clinical prostate implant with 71 125 I seeds as reference and we apply RayStretch to analyze its performance in worst-case scenarios. To do so, we design two cases where large calcifications are located in the prostate lobules. RayStretch resilience under various calcification density values is also explored. Comparisons against MC calculations are performed. Dose-volume histogram-related parameters like prostate D 90 , rectum D 2cc , or urethra D 10 obtained with RayStretch agree within a few percent with the detailed MC results for all cases considered. The robustness and compatibility of RayStretch with commercial treatment planning systems indicate its applicability in clinical practice for dosimetric corrections in prostate calcifications. Its use during intraoperative ultrasound planning is foreseen. Copyright © 2017 American Brachytherapy Society. Published by Elsevier Inc. All rights reserved.

  12. Occupational exposure in prostate permanent implants with I-125 seeds

    Energy Technology Data Exchange (ETDEWEB)

    Fdez Garcia, J.; Luna, V.; Sancho, J. M. g.; Martinez, J.; Galiano, P. S.; Jimenez, I.; Prada, P.; Juan, G.; Vivanco, J.

    2002-07-01

    Prostate brachytherapy is one of the techniques increasing faster in the environment of the radiotherapy and will probably go on increasing in the future. There are two forms in their use; by means of remote afterloading high dose rate (HDR) with Ir-192 radioactive sources or by means of permanent implant by manual/automatic afterloading of low dose rate (LDR) with seeds of I-125 or Pd-103. Iodine-125 has a half life of 59.4 days and it decays by electron capture with emissions of characteristic photons and electrons. The electrons are absorbed by the titanium wall of the I-125 seed. The principal photon emissions are 27.4 and 31.4 keV X-rays and a 35.5 keV gamma ray. Besides 22.1 and 25.2 keV fluorescent X-rays are also emitted resulting from interactions of the iodine-125 photons with the silver rod. The resulting average photon energy is approximately 27.4 keV. (Author)

  13. COMS eye plaque brachytherapy dosimetry simulations for 103Pd, 125I, and 131Cs

    International Nuclear Information System (INIS)

    Melhus, Christopher S.; Rivard, Mark J.

    2008-01-01

    Monte Carlo (MC) simulations were performed to estimate brachytherapy dose distributions for Collaborative Ocular Melanoma Study (COMS) eye plaques. Brachytherapy seed models 200, 6711, and CS-1 Rev2 carrying 103 Pd, 125 I, and 131 Cs radionuclides, respectively, were modeled and benchmarked against previously published values. Calculated dose rate constants MC Λ were 0.684, 0.924, and 1.052 cGy h -1 U -1 (±2.6%, k=1 uncertainty) for models 200, 6711, and CS-1 Rev2, respectively. The seeds were distributed into 10, 12, 14, 16, 18, 20, and 22 mm-diameter COMS eye plaques. Simulations were performed in both heterogeneous and homogeneous environments, where the latter were in-water and the former included the silastic seed carrier insert and gold-alloy plaque. MC-based homogenous central axis dose distributions agreed within 2%±1% (±1 s.d.) to hand-calculated values. For heterogeneous simulations, notable photon attenuation was observed, with dose reduction at 5 mm of 19%, 11%, and 9% for 103 Pd, 125 I, and 131 Cs, respectively. A depth-dependent correction factor was derived to correct homogenous central-axis dose distributions for plaque component heterogeneities, which were found to be significant at short radial distances

  14. Preparation of {sup 125}I-labeled monoclonal antibody of bladder neoplasm using lactoperoxidase

    Energy Technology Data Exchange (ETDEWEB)

    Huaifen, Li; Huisheng, Niu; Mingyue, Yuan; Yongzhi, Huang [Chinese Acaolemy of Medical Sciences, Tianjin (China). Inst. of Radiation Medicine

    1994-11-01

    {sup 125}I-labelled monoclonal antibody of bladder neoplasm ({sup 125}I-L{sub 4}B{sub 4}) is prepared using lactoperoxidase. The in-vivo radioactive distribution of {sup 125}I-L{sub 4}B{sub 4} in bare mice shows that {sup 125}I-L{sub 4}B{sub 4} concentrates in the tumour.

  15. Preparation of 125I-labeled monoclonal antibody of bladder neoplasm using lactoperoxidase

    International Nuclear Information System (INIS)

    Li Huaifen; Niu Huisheng; Yuan Mingyue; Huang Yongzhi

    1994-01-01

    125 I-labelled monoclonal antibody of bladder neoplasm ( 125 I-L 4 B 4 ) is prepared using lactoperoxidase. The in-vivo radioactive distribution of 125 I-L 4 B 4 in bare mice shows that 125 I-L 4 B 4 concentrates in the tumour

  16. Determination of the intrinsic energy dependence of LiF:Mg,Ti thermoluminescent dosimeters for 125I and 103Pd brachytherapy sources relative to 60Co

    International Nuclear Information System (INIS)

    Reed, J. L.; Micka, J. A.; Culberson, W. S.; DeWerd, L. A.; Rasmussen, B. E.; Davis, S. D.

    2014-01-01

    Purpose: To determine the intrinsic energy dependence of LiF:Mg,Ti thermoluminescent dosimeters (TLD-100) for 125 I and 103 Pd brachytherapy sources relative to 60 Co. Methods: LiF:Mg,Ti TLDs were irradiated with low-energy brachytherapy sources and with a 60 Co teletherapy source. The brachytherapy sources measured were the Best 2301 125 I seed, the OncoSeed 6711 125 I seed, and the Best 2335 103 Pd seed. The TLD light output per measured air-kerma strength was determined for the brachytherapy source irradiations, and the TLD light output per air kerma was determined for the 60 Co irradiations. Monte Carlo (MC) simulations were used to calculate the dose-to-TLD rate per air-kerma strength for the brachytherapy source irradiations and the dose to TLD per air kerma for the 60 Co irradiations. The measured and MC-calculated results for all irradiations were used to determine the TLD intrinsic energy dependence for 125 I and 103 Pd relative to 60 Co. Results: The relative TLD intrinsic energy dependences (relative to 60 Co) and associated uncertainties (k = 1) were determined to be 0.883 ± 1.3%, 0.870 ± 1.4%, and 0.871 ± 1.5% for the Best 2301 seed, OncoSeed 6711 seed, and Best 2335 seed, respectively. Conclusions: The intrinsic energy dependence of TLD-100 is dependent on photon energy, exhibiting changes of 13%–15% for 125 I and 103 Pd sources relative to 60 Co. TLD measurements of absolute dose around 125 I and 103 Pd brachytherapy sources should explicitly account for the relative TLD intrinsic energy dependence in order to improve dosimetric accuracy

  17. Determination of the intrinsic energy dependence of LiF:Mg,Ti thermoluminescent dosimeters for 125I and 103Pd brachytherapy sources relative to 60Co.

    Science.gov (United States)

    Reed, J L; Rasmussen, B E; Davis, S D; Micka, J A; Culberson, W S; DeWerd, L A

    2014-12-01

    To determine the intrinsic energy dependence of LiF:Mg,Ti thermoluminescent dosimeters (TLD-100) for (125)I and (103)Pd brachytherapy sources relative to (60)Co. LiF:Mg,Ti TLDs were irradiated with low-energy brachytherapy sources and with a (60)Co teletherapy source. The brachytherapy sources measured were the Best 2301 (125)I seed, the OncoSeed 6711 (125)I seed, and the Best 2335 (103)Pd seed. The TLD light output per measured air-kerma strength was determined for the brachytherapy source irradiations, and the TLD light output per air kerma was determined for the (60)Co irradiations. Monte Carlo (MC) simulations were used to calculate the dose-to-TLD rate per air-kerma strength for the brachytherapy source irradiations and the dose to TLD per air kerma for the (60)Co irradiations. The measured and MC-calculated results for all irradiations were used to determine the TLD intrinsic energy dependence for (125)I and (103)Pd relative to (60)Co. The relative TLD intrinsic energy dependences (relative to (60)Co) and associated uncertainties (k = 1) were determined to be 0.883 ± 1.3%, 0.870 ± 1.4%, and 0.871 ± 1.5% for the Best 2301 seed, OncoSeed 6711 seed, and Best 2335 seed, respectively. The intrinsic energy dependence of TLD-100 is dependent on photon energy, exhibiting changes of 13%-15% for (125)I and (103)Pd sources relative to (60)Co. TLD measurements of absolute dose around (125)I and (103)Pd brachytherapy sources should explicitly account for the relative TLD intrinsic energy dependence in order to improve dosimetric accuracy.

  18. Preparation of 19-iodocholesterol labelled with 125 I

    International Nuclear Information System (INIS)

    Rodriguez, L.; Rebollo, D. V.; Ruiz, J. M.

    1986-01-01

    In this paper a new method of synthesis of 19-iodo cholesterol labelled with ''125 I, from commercial cholesterol, is described. Its high chemical (96%) and radiochemical (99.9%) purities high yield and short time of preparation permit us to dispose or a more accessible labelled compound, which results appropriates for clinical investigations and in the diagnosis of disturbances of the suprarenal glands. (Author) 9 refs

  19. Long term results of 125I for treatment of hyperthyroidism

    International Nuclear Information System (INIS)

    Bremner, W.F.; McDougall, I.R.; Greig, W.R.; Ratcliffe, J.G.

    1976-01-01

    125 I emits very low energy conversion and Auger electrons. This radionuclide has been used in place of 131 I with the hope of reducing the incidence of post treatment hypothyroidism. 303 of 360 patients treated have been reviewed. Originally very large doses of 125 I were prescribed (751-1,600 μCi/g) but 9 out of 15 patients (60%) became hypothyroid, therefore 4 smaller therapeutic regimes were employed. (1) 55 patients received doses of 200 μCi or less/g thyroid, 69% are euthyroid and 24% hypothyroid after an average of 33 months from treatment. (2) 87 patients received doses of 201-350 μCi/g thyroid, 67% are euthyroid and 21% hypothyroid after an average follow up of 30 months. (3) 70 patients received doses of 351-500 μCi/g thyroid, 77% are euthyroid and 18% hypothyroid 36 months after treatment and (4) 76 patients received doses of 501-750 μCi/g, 41% are euthyroid and 56% hypothyroid 49 months after therapy. No long term complications such as thyroid cancer or leukaemia have occurred but because 125 I does not eliminate or reduce the incidence of post treatment hypothyroidism it probably should not be used in preference to 131 I for the routine treatment of hyperthyroidism

  20. {sup 125}I Labelling of Protein Using Immobilized Enzyme

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Jae Rok; Park, Kyung Bae; Awh, Ok Doo [Korea Advanced Energy Research Institute, Daejeon (Korea, Republic of)

    1984-03-15

    For an effective solid-phase labelling of protein with {sup 125}I, studies on the immobilization of lactoperoxidase (LPO) on the inner wall of polystyrene tubes were carried out. Labelling of bovine serum albumin (BSA) and insulin was also practiced using the LPO immobilized tubes. The immobilized enzyme of about 2.5 mu g/tube was sufficient for small scale labelling since the results of radio-paper chromatography of the labelling mixture of insulin indicated that the yields were sufficiently high (80%) even in the reactions conducted at room temperature for 60 sec. The results of the Sephadex column chromatography indicated that the labelled products were not contaminated with LPO-{sup 125}I, and the radiochemical purity of the products was more than 90%. In considering the general trend that the {sup 125}I labelled protein obtained by using LPO maintains its intactness better than those obtained by using chloramine-T, together with the tendency of yield enhancing with increase of reactants-concentration, the LPO immobilized tube method is estimated to be one of the simple methods of labelling. The product might be applicable without further purification.

  1. Labeling Lanreotide with 125I and 188Re

    International Nuclear Information System (INIS)

    Bai Hongsheng

    2000-01-01

    Lanreotide is a new somatostatin analogue. It can bind to human somatostatin receptor (hSSTR) subtype 2 through 5 with high affinity and to hSSTR subtype I with low affinity. We investigate labeling condition, quality control and stability in vitro of 125 I-Lanreotide and 188 Re-lanreotide respectively. (A) Lanreotide is labeled with 125 I using Chloramine T. The effect of reaction condition (such as reaction time, pH value, Lanreotide amount, quantity of Chloramine T and reaction volume) on labeling yield is investigated in detail. (B) The labeling yield and radiochemical purity (RP) is measured with paper chromatography (PC) and Sep-Pak C 18 Cartridge. (C) The stability of 125 I-Lanreotide in vitro is investigated by labeling compound incubating for 48 hours at 37 deg C in the 0.9% sodium chloride solution and RP is tested by PC at specific time intervals. (D) Lanreotide is labeled directly with 188 Re via the mixture of citrate and tartate using stannous chloride as reduced agent. The influence of reaction conditions such as pH, temperature, amount of stannous chloride, amount of Lanreotide and reaction time on labeling yield is investigated in detail. At the time, the stability in vitro quality control and animal test are evaluated

  2. Labeling Lanreotide with 125I and 188Re. China

    International Nuclear Information System (INIS)

    Bai Hongsheng

    2000-01-01

    Lanreotide (D-β-Nal-Cys-Try-D-Trp-Lys-Val-Cys-Thr-NH2) is a new somatostatin analogue. It can bind to human somatostatin receptor (hSSTR) subtype 2 through 5 with high affinity and to hSSTR subtype 1 with low affinity. We investigate labeling condition, quality control and stability in vitro of 125 I-Lanreotide and 188 Re-lanreotide respectively. (A) Lanreotide is labeled with 125 I using Chloramine T. The effect of reaction condition (such as reaction time, pH value, Lanreotide amount, quantity of Chloramine T and reaction volume) on labeling yield is investigated in detail. (B) The labeling yield and radiochemical purity (RP) is measured with paper chromatography (PC) and Sep-Pak C 18 Cartridge. For PC method, 125 I-Lanreotide is spotted on the Whatman No.1 paper and developed in the mixture of CH 3 CH 2 CH 2 CH 2 OH and CH 3 CH 2 OH and NH 4 OH (v/v/v=5:2:1), the Rf value of every component in the mobile phase is given in table 1. For Sep-Pak C 18 Cartridge methods each cartridge is washed with 10 ml of ethanol followed by 10 ml of iso-CH 3 CH 2 CH 2 OH solution. Aliquots of 0.1 mI sample is loaded onto the cartridge, unbound peptide (sodium iodine-125) is eluted with 5 ml of 0.5mol/L sodium acetate solution, 125 I-Lanreotide is eluted with 5 mI of 95% aqueous ethanol solution. (C) The stability of 125 I-Lanreotide in vitro is investigated by labeling compound incubating for 48 hours at 37 deg. C in the 0.9% sodium chloride solution and RP is tested by PC at specific time intervals. (D) Lanreotide is labeled directly with 188 Re via the mixture of citrate and tartate using stannous chloride as reduced agent. The influence of reaction conditions such as pH, temperature, amount of stannous chloride, amount of Lanreotide and reaction time on labeling yield is investigated in detail. At the time, the stability in vitro quality control and animal test are evaluated

  3. A comparative study of 19-iodo cholesterol-125I 3-acetate and Na 125I in liquid scintillation measurements

    International Nuclear Information System (INIS)

    Rodriguez Barquero, L.; Grau Malonda, A.; Los Arcos Merino, J. M.; Grau Carles, A.

    1994-01-01

    A comparative study of performance of 19-iodo cholesterol 1 25I 3-acetate and sodium iodide samples labeled with 125I is presented for liquid scintillation counting measurements. Quench effect, count rate stability and spectral evolution of samples have been followed for several weeks in Toluene, Hisafe II, Instagel, Dioxane-naphthalene and Toluene-alcohol scintillators. Organic samples have negligible quench effect in the interval of I concentration of 0-90 μg and inorganic samples only show a very small variation, lower than 12%, for Dioxane-naphthalene, in the same range of concentration. Satisfactory stability is obtained in general for both, organic and inorganic samples, but small counting losses, 0.03% for 19-iodocholesterol 1 I 3-acetate samples in Tolue ne-alcohol and 0 .04% for Na 125I samples in Dioxane-naphthalene and Toluene-alcohol, have been reported. (Author) 8 refs

  4. Preparation of 19-iodo cholesterol labelled with 125 I; Preparacion del 19-yodocolesterol marcado con 125 I

    Energy Technology Data Exchange (ETDEWEB)

    Rodriguez, L.; Rebollo, D. V.; Ruiz, J. M.

    1986-07-01

    In this paper a new method of synthesis of 19-iodo cholesterol labelled with ''125 I, from commercial cholesterol, is described. Its high chemical (96%) and radiochemical (99.9%) purities high yield and short time of preparation permit us to dispose or a more accessible labelled compound, which results appropriates for clinical investigations and in the diagnosis of disturbances of the suprarenal glands. (Author) 9 refs.

  5. Preparation of 19-iodo cholesterol labelled with 125 I; Preparacion del 19-yodocolesterol marcado con 125 I

    Energy Technology Data Exchange (ETDEWEB)

    Rodriguez, L; Rebollo, D V; Ruiz, J M

    1986-07-01

    In this paper a new method of synthesis of 19-iodo cholesterol labelled with ''125 I, from commercial cholesterol, is described. Its high chemical (96%) and radiochemical (99.9%) purities high yield and short time of preparation permit us to dispose or a more accessible labelled compound, which results appropriates for clinical investigations and in the diagnosis of disturbances of the suprarenal glands. (Author) 9 refs.

  6. Monte Carlo dosimetry for 125I and 103Pd eye plaque brachytherapy

    International Nuclear Information System (INIS)

    Thomson, R. M.; Taylor, R. E. P.; Rogers, D. W. O.

    2008-01-01

    A Monte Carlo study of dosimetry for eye plaque brachytherapy is performed. BrachyDose, an EGSnrc user code which makes use of Yegin's multi-geometry package, is used to fully model 125 I (model 6711) and 103 Pd (model 200) brachytherapy seeds and the standardized plaques of the Collaborative Ocular Melanoma Study (COMS). Three-dimensional dose distributions in the eye region are obtained. In general, dose to water is scored; however, the implications of replacing water with eye tissues are explored. The effect of the gold alloy (Modulay) backing is investigated and the dose is found to be sensitive to the elemental composition of the backing. The presence of the silicone polymer (Silastic) seed carrier results in substantial dose decreases relative to water, particularly for 103 Pd. For a 20 mm plaque with a Modulay backing and Silastic insert, fully loaded with 24 seeds, the dose decrease relative to water is of the order of 14% for 125 I and 20% for 103 Pd at a distance of 1 cm from the inner sclera along the plaque's central axis. For the configurations of seeds used in COMS plaques, interseed attenuation is a small effect within the eye region. The introduction of an air interface results in a dose reduction in its vicinity which depends on the plaque's position within the eye and the radionuclide. Introducing bone in the eye's vicinity also causes dose reductions. The dose distributions in the eye for the two different radionuclides are compared and, for the same prescription dose, 103 Pd generally offers a lower dose to critical normal structures. BrachyDose is sufficiently fast to allow full Monte Carlo dose calculations for routine clinical treatment planning.

  7. Ejaculatory Function After Permanent 125I Prostate Brachytherapy for Localized Prostate Cancer

    International Nuclear Information System (INIS)

    Huyghe, Eric; Delannes, Martine; Wagner, Fabien M.; Delaunay, Boris; Nohra, Joe; Thoulouzan, Matthieu; Shut-Yee, J. Yeung; Plante, Pierre; Soulie, Michel; Thonneau, Patrick; Bachaud, Jean Marc

    2009-01-01

    Purpose: Ejaculatory function is an underreported aspect of male sexuality in men treated for prostate cancer. We conducted the first detailed analysis of ejaculatory function in patients treated with permanent 125 I prostate brachytherapy for localized prostate cancer. Patients and Methods: Of 270 sexually active men with localized prostate cancer treated with permanent 125 I prostate brachytherapy, 241 (89%), with a mean age of 65 years (range, 43-80), responded to a mailed questionnaire derived from the Male Sexual Health Questionnaire regarding ejaculatory function. Five aspects of ejaculatory function were examined: frequency, volume, dry ejaculation, pleasure, and pain. Results: Of the 241 sexually active men, 81.3% had conserved ejaculatory function after prostate brachytherapy; however, the number of patients with rare/absent ejaculatory function was double the pretreatment number (p < .0001). The latter finding was correlated with age (p < .001) and the preimplant International Index of Erectile Function score (p < .001). However, 84.9% of patients with maintained ejaculatory function after implantation reported a reduced volume of ejaculate compared with 26.9% before (p < .001), with dry ejaculation accounting for 18.7% of these cases. After treatment, 30.3% of the patients experienced painful ejaculation compared with 12.9% before (p = .0001), and this was associated with a greater number of implanted needles (p = .021) and the existence of painful ejaculation before implantation (p < .0001). After implantation, 10% of patients who continued to be sexually active experienced no orgasm compared with only 1% before treatment. in addition, more patients experienced late/difficult or weak orgasms (p = .001). Conclusion: Most men treated with brachytherapy have conserved ejaculatory function after prostate brachytherapy. However, most of these men experience a reduction in volume and a deterioration in orgasm.

  8. Study on agroecology contamination from 125I gas and control measures in a simulated ecosystem

    International Nuclear Information System (INIS)

    Zhao Wenhu; Li Chuanzhao; Xu Shiming; Hou Lanxin; Shang Zhaorong; Li Xia

    1995-09-01

    The study was made in an air-tight space in which a simulated agricultural ecosystem was contaminated from 125 I gas. The contents of the study were summarized as follows: The space and time distribution of 125 I gas, contamination of foliage of the plants, accumulation and transfer of 125 I fallen on the soil and entered into the plants from the roots of crops and vegetables, the time distribution of 125 I in crops in water contaminated from 125 I fallout, distribution, accumulation and transfer of 125 I in chickens and rabbits which inhaled 125 I gas or fed the fodder contaminated from 125 I. The control measures of contamination in agroenvironment from 125 I were discussed. (7 refs., 20 figs., 29 tabs.)

  9. Radiation protection measures in case of 125I incorporation

    International Nuclear Information System (INIS)

    Strobelt, W.

    1976-01-01

    Thyroid measurements were performed on members of the scientific staff in the whole body counter of the Giessen Radiation Center with an aluminium encapsulated 3'' x 3'' dia. NaI(T1) detector; the personnel under investigation comprised those persons who either handled major quantities of 125 I or worked in the controlled area. The measuring setup, phantom calibration and the limits of measurement that can be attained are discussed. In a few cases of incorporation the effective halflife was determined. The radiation exposure was calculated by the absorbed fractions concept. A hazard is encountered almost exclusively in the iodization of the test substances. (orig./HP) [de

  10. Treatment of hyperthyroidism: use of 131I and 125I

    International Nuclear Information System (INIS)

    Atkins, H.L.

    1977-01-01

    Factors related to late hypothyroidism following the use of 131 I for treatment of hyperthyroidism are discussed with regard to age of patient, size of dose, previous surgery, immune status, and others. Possible reasons for the post-therapeutic hypothyroidism are discussed with regard to effects of radiation on the reproductive capacity of thyroid cells, effects of radiation on blood vessels, and dose distribution of radioiodine. The following therapeutic strategies are discussed: reduction of initial dose; multiple small doses; high dose radioiodine followed by replacement therapy; the use of external beam irradiation; and the use of 125 I

  11. Novel high resolution 125I brachytherapy source dosimetry using Ge-doped optical fibres

    International Nuclear Information System (INIS)

    Issa, Fatma; Hugtenburg, Richard P.; Nisbet, Andrew; Bradley, David A.

    2013-01-01

    The steep dose gradients close to brachytherapy sources limit the ability to obtain accurate measurements of dose. Here we use a novel high spatial resolution dosimeter to measure dose around a 125 I source and compare against simulations. Ge-doped optical fibres, used as thermoluminescent dosimeters, offer sub-mm spatial resolution, linear response from 10 cGy to >1 kGy and dose-rate independence. For a 125 I brachytherapy seed in a PMMA phantom, doses were obtained for source-dosimeter separations from 0.1 cm up to several cm, supported by EGSnrc/DOSRZznrc Monte Carlo simulations and treatment planning system data. The measurements agree with simulations to within 2.3%±0.3% along the transverse and perpendicular axes and within 3.0%±0.5% for measurements investigating anisotropy in angular dose distribution. Measured and Veriseed™ brachytherapy treatment planning system (TPS) values agreed to within 2.7%±0.5%. Ge-doped optical fibre dosimeters allow detailed dose mapping around brachytherapy sources, not least in situations of high dose gradient. - Highlights: • We evaluate fall-off in dose for distances from an 125 I source of 1 mm to 60 mm. • The TL of optical fibres accommodate high dose gradients and doses that reduce by a factor of 10 3 across the range of separations. • We verify measured values using DOSRZnrc Monte Carlo code simulations and the Variseed™ Treatment Planning System. • Measured radial and angular dose are obtained with ≤3% uncertainty

  12. Experimental and theoretical determination of dosimetric characteristics of IsoAid ADVANTAGETM125I brachytherapy source

    International Nuclear Information System (INIS)

    Meigooni, Ali S.; Hayes, Joshua L.; Zhang Hualin; Sowards, Keith

    2002-01-01

    125 I brachytherapy sources are being used for interstitial implants in tumor sites such as the prostate. Recently, the ADVANTAGE TM 125 I, Model IAI-125, source became commercially available for interstitial brachytherapy treatment. Dosimetric characteristics (dose rate constant, radial dose function, and anisotropy function) of this source were experimentally and theoretically determined, following the AAPM Task Group 43 recommendations. Derivation of the dose rate constant was based on recent NIST WAFAC calibration performed in accordance with their 1999 standard. Measurements were performed in Solid Water TM phantom using LiF thermoluminescent dosimeters. The theoretical calculations were performed in both Solid Water TM and water using the PTRAN Monte Carlo code. The results indicated that a dose rate constant of the new source in water was 0.98±0.03 cGy h -1 U -1 . The radial dose function of the new source was measured in Solid Water TM and calculated both in water and Solid Water TM at distances up to 10.0 cm. The anisotropy function, F(r,θ), of the new source was measured and calculated in Solid Water TM at distances of 2 cm, 3 cm, 5 cm, and 7 cm and also was calculated in water at distances ranging from 1 cm to 7 cm from the source. From the anisotropy function, the anisotropy factors and anisotropy constant were derived. The anisotropy constant of the ADVANTAGE TM 125 I source in water was found to be 0.97±0.03. The dosimetric characteristics of this new source compared favorably with those from the Amersham Health Model 6711 source. Complete dosimetric parameters of the new source are presented in this paper

  13. 125I iothalamate an ideal marker for glomerular filtration

    International Nuclear Information System (INIS)

    Odlind, B.; Haellgren, R.S.; Sohtell, M.; Lindstroem, B.

    1985-01-01

    The triiodinated angiographic contrast medium, iothalamate (usually labelled 125 I), has been used extensively as a marker for glomerular filtration. The authors have studied the renal handling of 125 I iothalamate (IOT) in vivo and in vitro in several species. In renal cortical slices from chicken, rabbit, rat, and monkey, the tissue-to-medium ratio of IOT was twice that of 51 Cr-EDTA (EDTA) at 37 degrees C; a difference that was abolished at 0 degree C and markedly reduced by added o-iodohippurate or iodipamide. In five chickens the steady-state renal clearance of IOT (CIOT) was twice that of EDTA (CEDTA) or 3 H inulin (C1); a difference that was abolished by administration of 100 mg/kg/hr of novobiocin, an organic anion transport inhibitor. CEDTA was similar to C1 before as well as after transport inhibition. Utilizing the Sperber technique the mean apparent tubular excretion fraction (ATEF) of IOT was 8%, while that of EDTA was 1%. After novobiocin coinfusion (new steady-state) ATEFIOT was significantly reduced and not different from that of EDTA (-1%). In the same animals the total urinary recovery of IOT was 84 and 57% before and after novobiocin, respectively, while corresponding values for EDTA was unchanged by the inhibitor. In seven rats the renal extraction of IOT was reduced from 29 to 17% by coinfusion of probenecid (5 mg/kg/hr). Corresponding extractions were 82 to 34% and 22% (unchanged) for PAH and EDTA, respectively

  14. Radioactive labelling with 125 I of infectious pancreatic necrosis virus

    International Nuclear Information System (INIS)

    Soler Ch, M.; Farias O, G.; Kuznar H, J.

    1993-01-01

    In order to understand the interaction between a cellular receptor and a ligand the photochemical crosslinking method has been widely used. This method has been utilized as an approach to determine the presence or absence of virus receptors in susceptible cells. Successful detection of crosslinks is achieved if one of the components, in the crosslinked product, has been radioactively labeled. The incorporation of a radioactive isotope, in the virus-receptor complex, enables the identification of the receptor. To undertake this study in the future, in this communication the radioactive labeling of virus particles is presented. The infectious necrosis pancreatic virus (IPN virus) was the chosen moiety to be in vitro labeled with 125 I using a direct method. Three oxidizing agents were used in the iodination procedure for comparison: an enzyme, lactoperoxidase and two chemical reagents, N-Chloro-benceno-sulfonamide (Iodo-Beads) and 1,3,4,6-Tetra chloro-3a,6a-diphenyl glycouril (Iodo-Gen). The results are analysed to select the method which guarantee the incorporation of 125 I in the viral capsid protein, while preserving its full infectivity. (author)

  15. The temperature effect of low-energy ion beam implantation on seed

    International Nuclear Information System (INIS)

    Chang Shenghe; Su Mingjie; Qin Guangyong; Wu Yuping; Zhao Haizhen

    2005-01-01

    The temperature effects of low-energy ion beam implantation on the seed germination were studied. Maize dry seeds were covered with copy paper, aluminum foil and without cover, respectively. Results showed that the germination rate of the seeds covered with paper which was the bad heat transmitter was the highest among three treatments, while that covered with aluminum foil which can transmit heat energy well was the least. The germination rate of the seeds covered with nothing was the second. Temperature affected seeds germination markedly. Generally the temperature of the target room inhibited the seeds' germination. After minus the effects of the temperature in the target room, the germination rates of the seeds were modified in this paper. The modified germination rate curve was also provided. (authors)

  16. Monte carlo simulation of penetration range distribution of ion beam with low energy implanted in plant seeds

    International Nuclear Information System (INIS)

    Huang Xuchu; Hou Juan; Liu Xiaoyong

    2009-01-01

    The depth and density distribution of V + ion beam implanted into peanut seed is simulated by the Monte Carlo method. The action of ions implanted in plant seeds is studied by the classical collision theory of two objects, the electronic energy loss is calculated by Lindhard-Scharff formulation. The result indicates that the depth of 200keV V + implanted into peanut seed is 5.57μm, which agrees with experimental results, and the model is appropriate to describe this interaction. This paper provides a computational method for the depth and density distribution of ions with low energy implanted in plant seeds. (authors)

  17. Dosimetric intercomparison of permanent Ho-166 seed's implants and HDR Ir-192 brachytherapy in breast cancer.

    Science.gov (United States)

    de Campos, Tarcisio Passos Ribeiro; Nogueira, Luciana Batista; Trindade, Bruno; Cuperschmid, Ethel Mizrahy

    2016-01-01

    To provide a comparative dosimetric analysis of permanent implants of Ho(166)-seeds and temporary HDR Ir(192)-brachytherapy through computational simulation. Brachytherapy with Ir(192)-HDR or LDR based on temporary wires or permanent radioactive seed implants can be used as dose reinforcement for breast radiation therapy. Permanent breast implants have not been a practical clinical routine; although, I(125) and Pd(103)-seeds have already been reported. Biodegradable Ho(166)-ceramic-seeds have been addressed recently. Simulations of implants of nine Ho(166)-seeds and equivalent with HDR Ir(192)-brachytherapy were elaborated in MCNP5, shaped in a computational multivoxel simulator which reproduced a female thorax phantom. Spatial dose rate distributions and dose-volume histograms were generated. Protocol's analysis involving exposure time, seed's activities and dose were performed. Permanent Ho(166)-seed implants presented a maximum dose rate per unit of contained activity (MDR) of 1.1601 μGy h(-1) Bq(-1); and, a normalized MDR in standard points (8 mm, equidistant to 03-seeds - SP1, 10 mm - SP2) of 1.0% (SP1) and 0.5% (SP2), respectively. Ir(192)-brachytherapy presented MDR of 4.3945 × 10(-3) μGy h(-1) Bq(-1); and, 30% (SP1), and 20% (SP2). Therefore, seed's implant activities of 333 MBq (Ho(166)) and 259 GBq (Ir(192)) produced prescribed doses of 58 Gy (SP1; 5d) and 56 Gy (SP1, 5 fractions, 6 min), respectively. Breast Ho(166)-implants of 37-111 MBq are attractive due to the high dose rate near 6-10 mm from seeds, equivalent to Ir(192)-brachytherapy of 259 GBq (3 fractions, 6 min) providing similar dose in standard points at a week; however, with spatial dose distribution better confined. The seed positioning can be adjusted for controlling the breast tumor, in stages I and II, in flat and deep tumors, without any breast volumetric limitation.

  18. (B1-/sup 125/I-desaminotyrosine)-insulin - A novel homogeneous insulin tracer

    Energy Technology Data Exchange (ETDEWEB)

    Bahrami, S; Zahn, H; Brandenburg, D [Deutsches Wollforschungsinstitut, Aachen (Germany F.R.); Machulla, H -J; Dutschka, K [Institut fuer Medizinische Strahlenphysik und Strahlenbiologie des Universitaetsklinikum, Essen (Germany F.R.)

    1980-10-28

    (B1-/sup 125/I-desaminotyrosine)-insulin (/sup 125/I-MII) was prepared with high specific activities (420 Ci/mmole) by exchanging B1-phenylalanine for /sup 125/I-p-hydroxyphenyl-propionic acid N-hydroxysuccinimide ester (Bolton-Hunter reagent). Overall radiochemical yields were about 8%. Analytical quality control and purification were performed by means of radio high pressure liquid chromatography. The radiochemical purity of /sup 125/I-MII was >99%, and the immunoprecipitability was 97%.

  19. Standardisation of 125I using seven techniques for radioactivity measurement

    International Nuclear Information System (INIS)

    Pomme, S.; Altzitzoglou, T.; Van Ammel, R.; Sibbens, G.

    2005-01-01

    Seven methods of radioactivity measurement were used to standardise an 125 I solution within the frame of an international key comparison organised by BIPM: photon-photon coincidence counting with two NaI detectors, photon sum-peak counting in a NaI well detector and in a 4π CsI(Tl) sandwich spectrometer, total emission counting in a windowless 4π CsI(Tl) sandwich spectrometer, electron-X,γ coincidence counting and electron-X,γ sum counting in a pressurised proportional counter inside a NaI well detector and liquid scintillation counting with the CIEMAT/NIST method. The solid sources were prepared by quantitative drop deposition with addition of AgNO 3 . The measurement methods, the results and the applied corrections are described and discussed

  20. 106Ru and 125I radiation dose rate gauge

    International Nuclear Information System (INIS)

    Machaj, B.; Swistowski, E.; Do Hoang Cuong

    2002-01-01

    Pulse count rate from plastic scintillator is a measure of the dose rate. Low dead time of measured channel and digital processing of measuring head signal with compensation of dead time enables correct registration of very high pulse count rate. The radiation source is set with an accuracy not worse than 0.1 mm in relation to the scintillator, and the movement of the source in horizontal and vertical direction is done with the accuracy of 0.01 mm. Additionally the gauge permits to measure the source activity and to check the uniform distribution of the radioactive material on the source surface. Random error due to pulse count rate fluctuation is negligible. The error due to instability of PTM gain is approx. 1,5% for 106 Ru and 5% for 125 I. (author)

  1. Biodistribution of gyroxin using 125I as radiotracer

    International Nuclear Information System (INIS)

    Alves da Silva, J.A.; Ribela, M.T.C.P.; Rogero, J.R.; Camillo, M.A.P.; Muramoto, E.

    2006-01-01

    The use of radiotracers in the research of animal venom has been scarce, although it allows an excellent approach to follow the process of bioavailability, biodistribution and kinetics of toxins. The purpose of this study was to assess gyroxin action mechanism, transport, compartments and action sites. This toxin is a thrombin-like and causes the barrel rotation syndrome. The gyroxin was labeled with 125 I and used as a tracer for the in vivo assay in mice. Blood samples and organs were collected at different time intervals, weighed and analyzed in a gamma-counter. The data was related with tissues distribution of protease activated receptor (PAR). Biodistribution assay allowed dividing the organs into three groups. The first one with the organs that followed the blood kinetics, the second with the organs related to metabolisms and elimination, and the third with the organs in which the gyroxin concentration increased during the observation period. (author)

  2. 125I radioimmunoassay for primary conjugated bile salts

    International Nuclear Information System (INIS)

    Spenney, J.G.; Johnson, B.J.; Hirschowitz, B.I.; Mihas, A.A.; Gibson, R.

    1977-01-01

    Cholylglycylhistamine, a derivative of cholic acid, has been synthesized and characterized. This derivative has been iodinated using Na125I and chloramine-T and purified free from unlabeled cholylglycylhistamine. Application of this iodinated bile salt derivative to radioimmunoassay of bile salts in human serum is reported. Antibody titers have uniformly increased over titers used in tritium-based assays; some antibodies are usable in dilutions of 1 : 80,000. The radioimmunoassay described here was found to measure predominantly the primary conjugated bile salts. Sensitivity has been maintained, with the least detectable amount being 0.5 pmoles per assay tube. Normal values in human serum are 3.47 +- 2.16 (SD) nmoles per ml

  3. Consumption of 125I labelled fibrinogen in normal subjects

    International Nuclear Information System (INIS)

    Langer, B.; Camargo, E.E.; Reis, J.M.M. dos; Carvalho, N.; Leao, L.E.P.

    1978-01-01

    The metabolism of iodine- 125 labeled human fibrinogen is studied by using three different sets of the radiopharmaceutical (0.9, 1.3 and 1.84 iodine atoms/fibrinogen molecule ratios) in 19 normal subjects. An aliquot of 40 μCi of fibrinogem- 125 I is injected in each subject, on normal dietary conditions and blood samples are withdrawn at 30, 60, 180, 36 and 720 minutes after the injection and, thereafter, one daily sample during 10 days. The compartmental distribution of the tracer is defined by plotting plasma and serum sample counts on a semilogarithmic graph paper. A rapid phase and 3 compartments are obtained. A 'rapid' consumption half-life and a 'real' consumption half-life are defined. The fibrinogen clottability is followed up to the last blood sample by checking the ratios of serum and plasma radioactivities [pt

  4. Solid phase 125I labelled radioimmunoassay for spermidine

    International Nuclear Information System (INIS)

    Zhao Shimin

    1991-01-01

    Using 125 I labelled monoclonal antibody against spermidine and solid phase antigen spermidine-bovine serum albumin conjugate, the radioimmunoassay for spermidine was developed. The sensitivity of this method was about 8 times higher than that of liquid phase 14 C labelled spermidine radioimmunoassay, reaching detection limit of 10 ng/ml (0.5 ng/tube). The working range of standard curve was 0-10 5 ng/ml. The new method was suitable for spermidine measurements in saliva, stomach fluid, and cerebrospinal fluid. The coefficients of variation (CV) of within and between-assay were 4% and 13%, respectively. Preliminary clinical measurements showed that the spermidine levels in saliva of cancer patients and in cerebrospinal fluid of leukemia patients were significantly elevated

  5. Pharmacokinetics and organ distribution of 125I-aprindine

    International Nuclear Information System (INIS)

    Becker, H.

    1981-01-01

    An attempt was made to label aprindine hydrochloride with I-125 by means of an exchange reaction. Organ distribution was determined in 10 rats where radioactivity was measured in the lung, heart, liver, kidney, spleen, brain, transverse muscle tissue and bone sections 5, 10, 30 and 60 min following i.v. injection. The high organ concentration was found in the lung, and also the maximum ratio organ: blood radioactivity was found for this organ. Whole body activity measurements revealed a half-life of nearly 6 hr. Excretion occurred primarily via the faeces. The pharmacokinetic properties of 14 C- and 125 I-aprindine hydrochloride do not therefore differ significantly. A whole body scintiscanning was carried out on an additional 12 rats and 6 rabbits. This revealed a marked enrichment in the lung compared to other organs in the time period 5 to 10 min. An image of relatively good quality was obtained compared to that of conventional perfusion scintiscanning with 131 I-HSA. It is assumed that 125 I-aprindine hydrochloride is concentrated in the lung parenchyma and is therefore largely unaffected by the immediate perfusion conditions. This is also confirmed in preliminary studies with 131 I-aprindine in the scintiscanning of rabbits where voids of pneumonia activity are shown in the aprindine scintigram whereas with the perfusion method these are not. As expected, the reverse was shown to be true following experimental pulmonary embolism where voids were seen in the perfusion scintigram whilst the 131 I-aprindine scintigram revealed hardly any areas of drops in activity. These properties possibly offer an improved diagnostic procedure for differentiating between pneumonia and lung infarct by combination with perfusion scintiscanning. (orig./MG) [de

  6. Effects of seed migration on post-implant dosimetry of prostate brachytherapy

    International Nuclear Information System (INIS)

    Gao, M.; Wang, J. Z.; Nag, S.; Gupta, N.

    2007-01-01

    Brachytherapy using permanent seed implants has been an effective treatment for prostate cancer. However, seeds will migrate after implant, thus making the evaluation of post-implant dosimetry difficult. In this study, we developed a computer program to simulate seed migration and analyzed dosimetric changes due to seed migration at various migration amounts. The study was based on 14 patients treated with Pd-103 at the James Cancer Hospital. Modeling of seed migration, including direction, distance as well as day of migration, was based on clinical observations. Changes of commonly used dosimetric parameters as a function of migration amount (2, 4, 6 mm respectively), prostate size (from 20 to 90 cc), and prostate region (central vs peripheral) were studied. Change of biological outcome (tumor control probability) due to migration was also estimated. Migration reduced prostate D90 to 99±2% of original value in 2 mm migration, and the reduction increased to 94±6% in 6 mm migration. The reduction of prostate dose led to a 14% (40%) drop in the tumor control probability for 2 mm (6 mm) migration, assuming radiosensitive tumors. However, migration has less effect on a prostate implanted with a larger number of seeds. Prostate V100 was less sensitive to migration than D90 since its mean value was still 99% of original value even in 6 mm migration. Migration also showed a different effect in the peripheral region vs the central region of the prostate, where the peripheral mean dose tended to drop more significantly. Therefore, extra activity implanted in the peripheral region during pre-plan can be considered. The detrimental effects of migration were more severe in terms of increasing the dose to normal structures, as rectum V50 may be 70% higher and urethra V100 may be 50% higher in the case of 6 mm migration. Quantitative knowledge of these effects is helpful in treatment planning and post-implant evaluation

  7. Activation of 125I-Factor IX and 125I-Factor X: Effect of tissue factor and Factor VII, Factor Xsub(a) and thrombin

    International Nuclear Information System (INIS)

    Oesterud, B.; Rapaport, S.I.

    Activation of Factor IX and Factor X was studied by adding 125 I-Factor IX or 125 I-Factor X to reaction mixtures and quantitating cleavage products by reduced sodium dodecylsulfate gel electrophoresis. Thrombin failed to activate Factors IX or X; Factor Xsub(a) produced insignificant amounts of cleavage products of both factors. In contrast, the reaction product of tissue factor and Factor VII cleaved large amounts of both Factor IX and Factor X in purified systems and in plasma. In incubation mixtures of plasma containing added 125 I-Factor IX or 125 I-Factor X, tissue factor and Ca 2+ ions, the percentage of total radioactivity in the heavy chain peak of 125 I-IXsub(a) and the heavy chain of 125 I-Xsub(a) increased at a similar rate. When the tissue factor was diluted, similar curves were obtained for percent cleavage of 125 I-Factor IX and percent cleavage of 125 I-Factor X plotted against tissue factor concentration. These findings support the hypothesis that activation of Factor IX by the tissue factor-Factor VII reaction product represents a physiologically significant step in normal haemostasis. (author)

  8. A magazine for the implantation of I-125 seeds in interstitial therapy of cerebral tumors

    International Nuclear Information System (INIS)

    Bockermann, V.; Dieckmann, G.; Lott, H.

    1988-01-01

    A compact magazine has been developed allowing a quick and easy implantation of I-125 seeds in interstitial therapy of intracranial tumors. The magazine is made of steel and has the shape of a right parallelepiped. One seed can be put each time into a movable insert. The magazine is connected to a normal application canula. It is easy to handle and contributes much to radioprotection. (orig.) [de

  9. The surgical viability and radiological monitoring of brain implants of bioactive micro-seeds in an animal model

    International Nuclear Information System (INIS)

    Silva, Giane X.O.; Campos, Tarcisio Passos Ribeiro de; Siqueira, Savio Lana; Maciel, Marcelo B.

    2005-01-01

    The interstitial implant is a therapeutic modality in brachytherapy of the head and neck. Presently, the seeds implanted in tumors in the central nervous system are metallic I-125. After the full emission of the radionuclide, the seed remains inert in the implanted area. Bioactive ceramic seeds have been prepared for this research group incorporating Sm-152 to be active in Sm-153. The main goal of the present study is the development of a the surgical technique for implanting the biodegradable radioactive micro-seeds in the brains of rabbits, as well as the observation of the clinical reactions of the animal after implantation of two sets of three seeds. The surgical procedure consisted of performing two separate perforations 10 mm from each other in the skull, permitting the implantation of two groups of three seeds, totaling six seeds. The results of the pilot study showed the effectiveness of the surgical procedure and of the biocompatibility of the seeds and the lack of presence of adverse reactions, functional sequels, or inflammation in a follow up 50 days post-surgery. Such seeds of reduced volume, 0.2 x 1.6 mm, could be monitored by computerized tomography 30 days after implanting. (author)

  10. Metabolism of (125I)tyramine cellobiose-labeled low density lipoproteins in squirrel monkeys

    International Nuclear Information System (INIS)

    Portman, O.W.; Alexander, Manfred

    1985-01-01

    Low density lipoproteins labeled with ( 125 I)tyramine cellobiose (( 125 I)TC-LDL) were removed from the circulation of squirrel monkeys at a similar but slightly slower rate than LDLs labeled with 125 I, ( 125 I)hydroxypenyl propionic acid, or ( 3 H)leucine. After the simultaneous injection of (( 125 I)TC-LDL) and ( 131 I)LDL labeled with 131 ICI, the 125 I was also removed at a slightly slower rate than 131 I. Most of the radioactivity was retained in tissues and not excreted during the 24 h after injection of ( 125 I)TC-LDL. This finding supports the claim of Pittman et al. (18) that ( 125 I)TC-LDL can be used to determine the irreversible uptake of LDL by different tissues. The liver cleared more LDL than any other organ, but the adrenals and ovaries were more active per gram. Trichloroacetic acid (TCA) precipitated more than 80% of the radioactivity in the tissues that had low 125 I uptake, but only about 50% of the 125 I in more active tissues (liver, adrenals, ovaries and spleen). Only a small percentage of 125 I in urine and bile was TCA-precipitable. In the dual label experiment with ( 125 I)TC-LDL and ( 131 I)LDL there was a selective retention of 125 I in samples from liver, spleen, adrenals, and perhaps testes, and an almost complete selectivity for 125 I in bile and feces. The aortic intima plus inner media (AIM) cleared much less LDL than other tissues, but the uptake by the entire AIM was proportional to the cholesterol concentration and weight of the total AIM. There was, however, no correlation between either of the latter two measurements and the uptake of LDL per pram of AIM. (author)

  11. Autoradiography for iodine-125 seeds

    International Nuclear Information System (INIS)

    Alberti, W.; Divoux, S.; Pothmann, B.; Tabor, P.; Hermann, K.P.; Harder, D.

    1993-01-01

    To study the interior design of model 6702 and 6711 iodine-125 seeds, contact autoradiographs were performed using mammography film. Improved resolution was obtained using a pin-hole camera with a hole of 0.1 mm x 0.1 mm. With these techniques, qualitative determination of the relative activity distribution within each seed was possible. The number of the activated resin spheres and the positions of the centers of these spheres can be exactly determined. A model calculation shows that variations in the arrangement of the activated spheres within a seed have a moderate influence on the dose distribution at source distances below 10 mm. Knowing the exact source configuration may be useful when comparing dose calculations with measured data for model 6702 125 I seeds which are currently employed in ophthalmic plaque and implant therapy of other tumors. 16 refs., 5 figs., 2 tabs

  12. Biological effects of low energy nitrogen ion implantation on Jatropha curcas L. seed germination

    International Nuclear Information System (INIS)

    Xu Gang; Wang Xiaoteng; Gan Cailing; Fang Yanqiong; Zhang Meng

    2012-01-01

    Highlights: ► We analyzed biological effects of N + implantation on dry Jatropha curcas seed. ► N + implantation greatly decreased seedling survival rate. ► At doses beyond 15 × 10 16 ion cm −2 , biological repair took place. ► CAT was essential for H 2 O 2 removal. POD mainly functioned as seed was severely hurt. ► HAsA–GSH cycle mainly contributed to the regeneration of HAsA. - Abstract: To explore the biological effects of nitrogen ion beam implantation on dry Jatropha curcas seed, a beam of N + with energy of 25 keV was applied to treat the dry seed at six different doses. N + beam implantation greatly decreased germination rate and seedling survival rate. The doses within the range of 12 × 10 16 to 15 × 10 16 ions cm −2 severely damaged the seeds: total antioxidant capacity (TAC), germination rate, seedling survival rate, reduced ascorbate acid (HAsA) and reduced glutathione (GSH) contents, and most of the tested antioxidases activity (i.e. catalase (CAT), ascorbate peroxidase (APX) and superoxide dismutase (SOD)) reached their lowest levels. At a dose of 18 × 10 16 ion cm −2 , biological repair took place: moderate increases were found in TAC, germination rate, seedling survival rate, HAsA and GSH contents, and some antioxidant enzyme activities (i.e. CAT, APX, SOD and GPX). The dose of 18 × 10 16 ions cm −2 may be the optimum dose for use in dry J. curcas seed mutation breeding. CAT, HAsA and GSH contributed to the increase of TAC, but CAT was the most important. POD performed its important role as seed was severely damaged. The main role of the HAsA–GSH cycle appeared to be for regeneration of HAsA.

  13. Effect of permanent 103Pd radioactive seed implantation on brachytherapy of malignant tumor

    International Nuclear Information System (INIS)

    Chen Ping; Wei Xianzhong; Liu Yanmin; Wu Kaijun; Liang Jianxin; Chen Hanzhang

    2003-01-01

    Objective: To investigate and assess the brachytherapeutic effectiveness of 103 Pd radioactive seeds in malignant tumor therapy. Methods: 196.1-2127.5 MBq 103 Pd seeds were implanted in 21 confirmed malignant tumor patients. The seeds were evenly scattered in 15/21 patients' tumors and peripherally in the remaining 6 cases' tumors. The size and shape, local recurrence and remote metastasis of the tumors were observed. Results: The brachytherapy of 103 Pd seeds in tumor patients resulted in obvious efficacy. No local recurrence and remote metastasis were observed. 19/21 (90.5%) patients scored 0 and 2/21 (9.5%) of them scored 1 in skin acute radiation morbidity scoring criteria within the observation period. Conclusion: The 103 Pd seeds can be safely used in brachytherapy of malignant tumors with lower or medium sensitivity to radiation therapy

  14. Optimization of sup 125 I ophthalmic plaque brachytherapy

    Energy Technology Data Exchange (ETDEWEB)

    Astrahan, M.A.; Luxton, G.; Jozsef, G.; Liggett, P.E.; Petrovich, Z. (Univ. of Southern California School of Medicine, Los Angeles (USA))

    1990-11-01

    Episcleral plaques containing {sup 125}I sources are often used in the treatment of ocular melanoma. Within four years post-treatment, however, the majority of patients experience some visual loss due to radiation retinopathy. The high incidence of late complications suggests that careful treatment optimization may lead to improved outcome. The goal of optimization would be to reduce the magnitude of vision-limiting complications without compromising tumor control. We have developed a three-dimensional computer model for ophthalmic plaque therapy which permits us to explore the potential of various optimization strategies. One simple strategy which shows promise is to maximize the ratio of dose to the tumor apex (T) compared to dose to the macula (M). By modifying the parameters of source location, activity distribution, source orientation, and shielding we find that the calculated T:M ratio can be varied by a factor of 2 for a common plaque design and posterior tumor location. Margins and dose to the tumor volume remain essentially unchanged.

  15. Quality control of system of imaging for rectal ultrasound for implants seed prostate low rate

    International Nuclear Information System (INIS)

    Luquero Llopis, N.; Ferrer Gracia, C.; Huertas Martinez, C.; Huerga Cabrerizo, C.; Corredoira Silva, E.; Serrada Hierro, A.

    2013-01-01

    In this work, the objective is the evaluation of the image system used in implants of prostate of low rate held at our hospital, for maximum control on the placement of the seeds in the patient and therefore carried out dosimetry. (Author)

  16. Localized whole eye radiotherapy for retinoblastoma using a 125I applicator, 'claws'

    International Nuclear Information System (INIS)

    Stannard, Clare; Sealy, Rossall; Hering, Egbert; Korrubel, Jan; Hill, John; Barron, Adrian; Knowles, Ruth

    2001-01-01

    Purpose: To treat children with retinoblastoma, who require whole eye radiotherapy, with a specially designed 125 I applicator that irradiates the eye while sparing the surrounding tissues. Methods and Materials: Under general anesthesia, a pericorneal ring is attached to the 4 extraocular muscles, and 4 appendages, each loaded with 125 I seeds, are inserted beneath the conjunctiva in-between each pair of muscles and attached anteriorly to the ring. Twenty-nine eyes were treated. Eighteen received a median dose of 28 Gy during 91 hours and 11 received 40 Gy during 122 hours, when the relative biologic effectiveness was taken as 1 instead of 1.5. Six had received prior chemotherapy. Results: Twenty-four eyes were followed up for 2-157 months (median 29). Although 22 eyes responded, local control was achieved in 13 patients, 3 of whom required additional treatment for new tumors; a further 3 required additional treatment for tumor recurrence as well as new tumors. One of these eyes was enucleated for neovascular glaucoma. All 6 Group I-III eyes and 6 of 18 Group V eyes were retained for 2-157 months (median 39), with good vision in 10 eyes. Three developed cataracts 7, 8, and 12 years later, 1 of which has been removed. Conclusions: This is a new way of irradiating the whole eye with a minimal dose to the surrounding tissues. The treatment time is only 5 days. It is effective in Groups I-III, but only 33% of Group V eyes retained vision. No late cosmetic defects occurred

  17. Permanent interstitial implantation of 125Iodine seed for thoracic malignant tumors

    International Nuclear Information System (INIS)

    Xu Zhongheng; Qian Yongyue; Wu Jinchang; Liu Zengli

    2002-01-01

    Objective: To observe effect of 125 Iodine sed on interstitial brachytherapy of patient with thoracic malignant tumor. Methods: 125 Iodine seed were inserted into the target tissue and permanent left there for brachytherapy in 6 cases of thoracic malignant tumors, which including lung cancer, Pancoast's tumour, mediastinal malignant schwannoma. Results: All cases were rehabilitated shortly after operation. The implanted lesions remained controlled now and in dead patients. No radiation-related and 125 Iodine seed-related complications occurred. Conclusion: Brachytherapy by implantation of 125 Iodine seeds of remained tumor tissue in patients with thoracic malignant tumor after operation has a satisfactory outcome. This therapy can control local recurrent of thoracic malignant tumor. But the results in long term should be studied further

  18. An improved synthesis of [125I]N-(diethylaminoethyl)-4-iodobenzamide: a potential ligand for imaging malignant melanoma

    International Nuclear Information System (INIS)

    John, C.S.; Reba, R.C.; Varma, V.M.; McAfee, J.G.; Saga, T.; Kinuya, S.; Le, N.; Jeong, J.M.; Paik, C.H.

    1993-01-01

    To improve the radiolabeling yield and the specific activity of [ 125 I]N-(2-diethylaminoethyl)-4-iodobenzamide(DAB), the aryltributyltin precursor was synthesized from the N-(2-diethylaminoethyl)-4-bromobenzamide derivative by palladium catalyzed stannylation using bis(tributyltin). The radiolabeled product, [ 125 I]DAB, was obtained by an iododestannylation reaction in high radiochemical yields (85-94%, radiochemical purity, > 98%) using chloramine-T as an oxidizing agent. The specific activity was greater than 1600 Ci/mmol. The biodistribution studies in nude mice implanted with human malignant melanoma xenograft showed a good tumor uptake (6.14% ID/g at 1 h, 2.81% ID/g at 6 h and 0.42% ID/g at 24 h) of [ 125 I]DAB. Unfortunately, a high uptake in the non-target organs, such as liver and lung was found. At 1 h post-injection the activity level in liver and lung was 11.76 and 7.58% ID/g, respectively. A slow clearance of activity from liver and lung was observed at 6 h (3.43 and 0.49% ID/g). These results demonstrate that iodinated IDAB is a potential radiopharmaceutical for the management of patients with malignant melanoma. (Author)

  19. An improved synthesis of [[sup 125]I]N-(diethylaminoethyl)-4-iodobenzamide: a potential ligand for imaging malignant melanoma

    Energy Technology Data Exchange (ETDEWEB)

    John, C.S.; Reba, R.C.; Varma, V.M.; McAfee, J.G. (Georgetown Univ. Medical Center, Washington, DC (United States)); Saga, T.; Kinuya, S.; Le, N.; Jeong, J.M.; Paik, C.H. (National Insts. of Health, Bethesda, MD (United States))

    1993-01-01

    To improve the radiolabeling yield and the specific activity of [[sup 125]I]N-(2-diethylaminoethyl)-4-iodobenzamide(DAB), the aryltributyltin precursor was synthesized from the N-(2-diethylaminoethyl)-4-bromobenzamide derivative by palladium catalyzed stannylation using bis(tributyltin). The radiolabeled product, [[sup 125]I]DAB, was obtained by an iododestannylation reaction in high radiochemical yields (85-94%, radiochemical purity, > 98%) using chloramine-T as an oxidizing agent. The specific activity was greater than 1600 Ci/mmol. The biodistribution studies in nude mice implanted with human malignant melanoma xenograft showed a good tumor uptake (6.14% ID/g at 1 h, 2.81% ID/g at 6 h and 0.42% ID/g at 24 h) of [[sup 125]I]DAB. Unfortunately, a high uptake in the non-target organs, such as liver and lung was found. At 1 h post-injection the activity level in liver and lung was 11.76 and 7.58% ID/g, respectively. A slow clearance of activity from liver and lung was observed at 6 h (3.43 and 0.49% ID/g). These results demonstrate that iodinated IDAB is a potential radiopharmaceutical for the management of patients with malignant melanoma. (Author).

  20. A greedy heuristic using adjoint functions for the optimization of seed and needle configurations in prostate seed implant

    Energy Technology Data Exchange (ETDEWEB)

    Yoo, Sua [Department of Radiation Oncology, Duke University Medical Center, Box 3295, Durham, NC 27710 (United States); Kowalok, Michael E [Department of Radiation Oncology, Virginia Commonwealth University Health System, 401 College St., PO Box 980058, Richmond, VA 23298-0058 (United States); Thomadsen, Bruce R [Department of Medical Physics, University of Wisconsin-Madison, 1530 MSC, 1300 University Ave., Madison, WI 53706 (United States); Henderson, Douglass L [Department of Engineering Physics, University of Wisconsin-Madison, 153 Engineering Research Bldg., 1500 Engineering Dr., Madison, WI 53706 (United States)

    2007-02-07

    We continue our work on the development of an efficient treatment-planning algorithm for prostate seed implants by incorporation of an automated seed and needle configuration routine. The treatment-planning algorithm is based on region of interest (ROI) adjoint functions and a greedy heuristic. As defined in this work, the adjoint function of an ROI is the sensitivity of the average dose in the ROI to a unit-strength brachytherapy source at any seed position. The greedy heuristic uses a ratio of target and critical structure adjoint functions to rank seed positions according to their ability to irradiate the target ROI while sparing critical structure ROIs. Because seed positions are ranked in advance and because the greedy heuristic does not modify previously selected seed positions, the greedy heuristic constructs a complete seed configuration quickly. Isodose surface constraints determine the search space and the needle constraint limits the number of needles. This study additionally includes a methodology that scans possible combinations of these constraint values automatically. This automated selection scheme saves the user the effort of manually searching constraint values. With this method, clinically acceptable treatment plans are obtained in less than 2 min. For comparison, the branch-and-bound method used to solve a mixed integer-programming model took close to 2.5 h to arrive at a feasible solution. Both methods achieved good treatment plans, but the speedup provided by the greedy heuristic was a factor of approximately 100. This attribute makes this algorithm suitable for intra-operative real-time treatment planning.

  1. A greedy heuristic using adjoint functions for the optimization of seed and needle configurations in prostate seed implant

    International Nuclear Information System (INIS)

    Yoo, Sua; Kowalok, Michael E; Thomadsen, Bruce R; Henderson, Douglass L

    2007-01-01

    We continue our work on the development of an efficient treatment-planning algorithm for prostate seed implants by incorporation of an automated seed and needle configuration routine. The treatment-planning algorithm is based on region of interest (ROI) adjoint functions and a greedy heuristic. As defined in this work, the adjoint function of an ROI is the sensitivity of the average dose in the ROI to a unit-strength brachytherapy source at any seed position. The greedy heuristic uses a ratio of target and critical structure adjoint functions to rank seed positions according to their ability to irradiate the target ROI while sparing critical structure ROIs. Because seed positions are ranked in advance and because the greedy heuristic does not modify previously selected seed positions, the greedy heuristic constructs a complete seed configuration quickly. Isodose surface constraints determine the search space and the needle constraint limits the number of needles. This study additionally includes a methodology that scans possible combinations of these constraint values automatically. This automated selection scheme saves the user the effort of manually searching constraint values. With this method, clinically acceptable treatment plans are obtained in less than 2 min. For comparison, the branch-and-bound method used to solve a mixed integer-programming model took close to 2.5 h to arrive at a feasible solution. Both methods achieved good treatment plans, but the speedup provided by the greedy heuristic was a factor of approximately 100. This attribute makes this algorithm suitable for intra-operative real-time treatment planning

  2. Conventional Versus Automated Implantation of Loose Seeds in Prostate Brachytherapy: Analysis of Dosimetric and Clinical Results

    International Nuclear Information System (INIS)

    Genebes, Caroline; Filleron, Thomas; Graff, Pierre; Jonca, Frédéric; Huyghe, Eric; Thoulouzan, Matthieu; Soulie, Michel; Malavaud, Bernard; Aziza, Richard; Brun, Thomas; Delannes, Martine; Bachaud, Jean-Marc

    2013-01-01

    Purpose: To review the clinical outcome of I-125 permanent prostate brachytherapy (PPB) for low-risk and intermediate-risk prostate cancer and to compare 2 techniques of loose-seed implantation. Methods and Materials: 574 consecutive patients underwent I-125 PPB for low-risk and intermediate-risk prostate cancer between 2000 and 2008. Two successive techniques were used: conventional implantation from 2000 to 2004 and automated implantation (Nucletron, FIRST system) from 2004 to 2008. Dosimetric and biochemical recurrence-free (bNED) survival results were reported and compared for the 2 techniques. Univariate and multivariate analysis researched independent predictors for bNED survival. Results: 419 (73%) and 155 (27%) patients with low-risk and intermediate-risk disease, respectively, were treated (median follow-up time, 69.3 months). The 60-month bNED survival rates were 95.2% and 85.7%, respectively, for patients with low-risk and intermediate-risk disease (P=.04). In univariate analysis, patients treated with automated implantation had worse bNED survival rates than did those treated with conventional implantation (P<.0001). By day 30, patients treated with automated implantation showed lower values of dose delivered to 90% of prostate volume (D90) and volume of prostate receiving 100% of prescribed dose (V100). In multivariate analysis, implantation technique, Gleason score, and V100 on day 30 were independent predictors of recurrence-free status. Grade 3 urethritis and urinary incontinence were observed in 2.6% and 1.6% of the cohort, respectively, with no significant differences between the 2 techniques. No grade 3 proctitis was observed. Conclusion: Satisfactory 60-month bNED survival rates (93.1%) and acceptable toxicity (grade 3 urethritis <3%) were achieved by loose-seed implantation. Automated implantation was associated with worse dosimetric and bNED survival outcomes

  3. Conventional Versus Automated Implantation of Loose Seeds in Prostate Brachytherapy: Analysis of Dosimetric and Clinical Results

    Energy Technology Data Exchange (ETDEWEB)

    Genebes, Caroline, E-mail: genebes.caroline@claudiusregaud.fr [Radiation Oncology Department, Institut Claudius Regaud, Toulouse (France); Filleron, Thomas; Graff, Pierre [Radiation Oncology Department, Institut Claudius Regaud, Toulouse (France); Jonca, Frédéric [Department of Urology, Clinique Ambroise Paré, Toulouse (France); Huyghe, Eric; Thoulouzan, Matthieu; Soulie, Michel; Malavaud, Bernard [Department of Urology and Andrology, CHU Rangueil, Toulouse (France); Aziza, Richard; Brun, Thomas; Delannes, Martine; Bachaud, Jean-Marc [Radiation Oncology Department, Institut Claudius Regaud, Toulouse (France)

    2013-11-15

    Purpose: To review the clinical outcome of I-125 permanent prostate brachytherapy (PPB) for low-risk and intermediate-risk prostate cancer and to compare 2 techniques of loose-seed implantation. Methods and Materials: 574 consecutive patients underwent I-125 PPB for low-risk and intermediate-risk prostate cancer between 2000 and 2008. Two successive techniques were used: conventional implantation from 2000 to 2004 and automated implantation (Nucletron, FIRST system) from 2004 to 2008. Dosimetric and biochemical recurrence-free (bNED) survival results were reported and compared for the 2 techniques. Univariate and multivariate analysis researched independent predictors for bNED survival. Results: 419 (73%) and 155 (27%) patients with low-risk and intermediate-risk disease, respectively, were treated (median follow-up time, 69.3 months). The 60-month bNED survival rates were 95.2% and 85.7%, respectively, for patients with low-risk and intermediate-risk disease (P=.04). In univariate analysis, patients treated with automated implantation had worse bNED survival rates than did those treated with conventional implantation (P<.0001). By day 30, patients treated with automated implantation showed lower values of dose delivered to 90% of prostate volume (D90) and volume of prostate receiving 100% of prescribed dose (V100). In multivariate analysis, implantation technique, Gleason score, and V100 on day 30 were independent predictors of recurrence-free status. Grade 3 urethritis and urinary incontinence were observed in 2.6% and 1.6% of the cohort, respectively, with no significant differences between the 2 techniques. No grade 3 proctitis was observed. Conclusion: Satisfactory 60-month bNED survival rates (93.1%) and acceptable toxicity (grade 3 urethritis <3%) were achieved by loose-seed implantation. Automated implantation was associated with worse dosimetric and bNED survival outcomes.

  4. Use of (3H) and (125I) tracers in steroid radioimmunoassays

    International Nuclear Information System (INIS)

    Jeffcoate, S.L.

    1975-01-01

    The comparative use of 3 H and 125 I tracers in steroid radioimmunoassays will be discussed around the following points: - 3 H. Advantages: they can be purchased commercially and have a long shelf-life. Disadvantages: they may have reduced affinity for antibodies due to ''isotope effects''; the counting of β-emitters is more expensive and difficult; 3 H tracers are not available for all steroids. - 125 I. Advantages: gamma-counting is cheaper, simpler and more precise; 125 I tracers may have higher affinity for antibodies than unlabelled steroids; 125 I can be used to label any steroid. Disadvantages: 125 I tracers have a limited shelf-life (n.b. six months for 125 I histamine tracers). The high affinity of some tracers will be a big disadvantage if the unlabelled steroid cannot compete effectively

  5. Synthesis of [125I]iodoDPA-713: A new probe for imaging inflammation

    International Nuclear Information System (INIS)

    Wang, Haofan; Pullambhatla, Mrudula; Guilarte, Tomas R.; Mease, Ronnie C.; Pomper, Martin G.

    2009-01-01

    [ 125 I]IodoDPA-713 [ 125 I]1, which targets the translocator protein (TSPO, 18 kDa), was synthesized in seven steps from methyl-4-methoxybenzoate as a tool for quantification of inflammation in preclinical models. Preliminary in vitro autoradiography and in vivo small animal imaging were performed using [ 125 I]1 in a neurotoxicant-treated rat and in a murine model of lung inflammation, respectively. The radiochemical yield of [ 125 I]1 was 44 ± 6% with a specific radioactivity of 51.8 GBq/μmol (1400 mCi/μmol) and >99% radiochemical purity. Preliminary studies showed that [ 125 I]1 demonstrated increased specific binding to TSPO in a neurotoxicant-treated rat and increased radiopharmaceutical uptake in the lungs of an experimental inflammation model of lung inflammation. Compound [ 125 I]1 is a new, convenient probe for preclinical studies of TSPO activity.

  6. Prostate brachytherapy postimplant dosimetry: Seed orientation and the impact of dosimetric anisotropy in stranded implants

    International Nuclear Information System (INIS)

    Chng, Nicholas; Spadinger, Ingrid; Rasoda, Rosey; Morris, W. James; Salcudean, Septimiu

    2012-01-01

    Purpose: In postimplant dosimetry for prostate brachytherapy, dose is commonly calculated using the TG-43 1D formalism, because seed orientations are difficult to determine from CT images, the current standard for the procedure. However, the orientation of stranded seeds soon after implantation is predictable, as these seeds tend to maintain their relative spacing, and orient themselves along the implant trajectory. The aim of this study was to develop a method for determining seed orientations from reconstructed strand trajectories, and to use this information to investigate the dosimetric impact of applying the TG-43 2D formalism to clinical postimplant analysis. Methods: Using in-house software, the preplan to postimplant seed correspondence was determined for a cohort of 30 patients during routine day-0 CT-based postimplant dosimetry. All patients were implanted with stranded-seed trains. Spline curves were fit to each set of seeds composing a strand, with the requirement that the distance along the spline between seeds be equal to the seed spacing within the strand. The orientations of the seeds were estimated by the tangents to the spline at each seed centroid. Dose distributions were then determined using the 1D and 2D TG-43 formalisms. These were compared using the TG-137 recommended dose metrics for the prostate, prostatic urethra, and rectum. Results: Seven hundred and sixty one strands were analyzed in total. Defining the z-axis to be cranial-positive and the x-axis to be left-lateral positive in the CT coordinate system, the average seed had an inclination of 21 deg. ± 10 deg. and an azimuth of -81 deg. ± 57 deg. These values correspond to the average strand rising anteriorly from apex to base, approximately parallel to the midsagittal plane. Clinically minor but statistically significant differences in dose metrics were noted. Compared to the 2D calculation, the 1D calculation underestimated prostate V100 by 1.1% and D90 by 2.3 Gy, while

  7. Influence of glucose and urea on 125I transport across an anion exchange paper membrane

    International Nuclear Information System (INIS)

    Inoue, Hiroyoshi

    2001-01-01

    In order to study the influence of glucose and urea on the 125 I transport across an anion exchange paper membrane, the transmembrane potential, the fluxes, and the concentrations of 125 I, glucose and urea within the membrane were measured in the Na 125 I concentration-cell system containing glucose or urea. Glucose and urea increased the membrane/solution distribution of the iodide ion, but scarcely affected the diffusion process of iodide ion within the membrane

  8. Effects of lysosomal inhibitors on 125I-insulin and 125I-asialofetuin degradation by the isolated, perfused rat liver and isolated rat hepatocytes

    International Nuclear Information System (INIS)

    Ward, W.F.; Moss, A.L.

    1985-01-01

    To further evaluate the role of the lysosomal system in insulin degradation, the authors have compared the effects of inhibitors of lysosomal function on the degradation of 125 I-insulin with 125 I-asialofetuin, a lysosomally targeted molecule, by the intact, perfused rat liver and the isolated rat hepatocyte. The inhibitors employed were chloroquine ( 125 microM), NH 4 Cl (10 mM), and leupeptin (50 micrograms/ml). In the intact, perfused liver the observed inhibition of 125 I-asialofetuin degradation at 30 min was as follows: chloroquine, 38%; NH 4 Cl, 32%; and leupeptin, 86%. Chloroquine also inhibited 125 I-insulin degradation in the intact, perfused liver (29%), but NH 4 Cl and leupeptin had no effect. Using the isolated hepatocyte, the observed values for inhibition of 125I-asialofetuin at 60 min were: chloroquine, 85%; NH 4 Cl, 76%; and leupeptin, 81%. Chloroquine produced a 28% inhibition of 125I-insulin degradation, while NH 4 Cl and leupeptin had no effect. Chloroquine and NH 4 Cl decreased cell-associated radioactivity when isolated hepatocytes were incubated with 125I-asialofetuin (leupeptin had no effect), whereas chloroquine caused a 107% increase in cell-associated radioactivity when 125I-insulin was added to the incubation media (NH 4 Cl and leupeptin had no effect). These results indicate that the effects of chloroquine on insulin degradation are an extralysosomal action and that lysosomes appear not to be involved in the physiologic degradation of the insulin molecule

  9. Binding of in vivo administrated 125-I-triiodothyronine by the rat liver mitochondria

    International Nuclear Information System (INIS)

    Fiedorowicz, K.; Nauman, A.; Nauman, J.

    1979-01-01

    In vivo administrated 125 I-triiodothyronine ( 125 I-T 3 ) was bound by the rat liver mitochondria. About 10 % of hormone was bound with external mitochondrial membrane while the remaining part with matrix and inner mitochondrial membrane. The highest accumulation of 125 I-T 3 in mitochondria was observed 30 min after injection while in the whole liver homogenate the highest hormone accumulation appeared 15 min post injection. Mitochondrial binding sites have a great capacity for T 3 which makes impossible estimation of the kinetic parameters of triiodothyronine-mitochondrium interaction by means of saturation and displacement of 125 I-T 3 . (author)

  10. Relationship between isotope half-life and prostatic edema for optimal prostate dose coverage in permanent seed implants

    International Nuclear Information System (INIS)

    Villeneuve, Maxime; Leclerc, Ghyslain; Lessard, Etienne; Pouliot, Jean; Beaulieu, Luc

    2008-01-01

    The robustness of treatment planning to prostatic edema for three different isotopes ( 125 I, 103 Pd, and 131 Cs) is explored using dynamical dose calculations on 25 different clinical prostate cases. The treatment plans were made using the inverse planning by simulated annealing (IPSA) algorithm. The prescription was 144, 127, and 125 Gy for 125 I, 131 Cs, and 103 Pd, respectively. For each isotope, three dose distribution schemes were used to impose different protection levels to the urethra: V 120 =0%, V 150 =0%, and V 150 =30%. Eleven initial edema values were considered ranging from 1.0 (no edema) to 2.0 (100%). The edema was assumed to resolve exponentially with time. The prostate volume, seed positions, and seed activity were dynamically tracked to produce the final dose distribution. Edema decay half-lives of 10, 30, and 50 days were used. A total of 675 dynamical calculations were performed for each initial edema value. For the 125 I isotope, limiting the urethra V 120 to 0% leads to a prostate D 90 under 140 Gy for initial edema values above 1.5. Planning with urethra V 150 at 0% provides a good response to the edema; the prostate D 90 remains higher than 140 Gy for edema values up to 1.8 and a half-life of 30 days or less. For 103 Pd, the prostate D 90 is under 97% of the prescription dose for approximately 66%, 40%, and 30% of edema values for urethra V 120 =0%, V 150 =0%, and V 150 =30%, respectively. Similar behavior is seen for 131 Cs and the center of the prostate becomes 'cold' for almost all edema scenarios. The magnitude of the edema following prostate brachytherapy, as well as the half-life of the isotope used and that of the edema resorption, all have important impacts on the dose distribution. The 125 I isotope with its longer half-life is more robust to prostatic edema. Setting up good planning objectives can provide an adequate compromise between organ doses and robustness. This is even more important since seed misplacements will contribute

  11. Biological effects of low energy nitrogen ion implantation on Jatropha curcas L. seed germination

    Science.gov (United States)

    Xu, Gang; Wang, Xiao-teng; Gan, Cai-ling; Fang, Yan-qiong; Zhang, Meng

    2012-09-01

    To explore the biological effects of nitrogen ion beam implantation on dry Jatropha curcas seed, a beam of N+ with energy of 25 keV was applied to treat the dry seed at six different doses. N+ beam implantation greatly decreased germination rate and seedling survival rate. The doses within the range of 12 × 1016 to 15 × 1016 ions cm-2 severely damaged the seeds: total antioxidant capacity (TAC), germination rate, seedling survival rate, reduced ascorbate acid (HAsA) and reduced glutathione (GSH) contents, and most of the tested antioxidases activity (i.e. catalase (CAT), ascorbate peroxidase (APX) and superoxide dismutase (SOD)) reached their lowest levels. At a dose of 18 × 1016 ion cm-2, biological repair took place: moderate increases were found in TAC, germination rate, seedling survival rate, HAsA and GSH contents, and some antioxidant enzyme activities (i.e. CAT, APX, SOD and GPX). The dose of 18 × 1016 ions cm-2 may be the optimum dose for use in dry J. curcas seed mutation breeding. CAT, HAsA and GSH contributed to the increase of TAC, but CAT was the most important. POD performed its important role as seed was severely damaged. The main role of the HAsA-GSH cycle appeared to be for regeneration of HAsA.

  12. A comparative study of 19-iodo cholesterol-125I 3-acetate and Na 125I in liquid scintillation measurements; Estudio comparativo del acetato de 19-iodocolesterol- -125I con Nal25I en medidas por centelleo liquido

    Energy Technology Data Exchange (ETDEWEB)

    Rodriguez Barquero, L.; Grau Malonda, A.; Los Arcos Merino, J. M.; Grau Carles, A.

    1994-07-01

    A comparative study of performance of 19-iodo cholesterol {sup 1}25I 3-acetate and sodium iodide samples labeled with 125I is presented for liquid scintillation counting measurements. Quench effect, count rate stability and spectral evolution of samples have been followed for several weeks in Toluene, Hisafe II, Instagel, Dioxane-naphthalene and Toluene-alcohol scintillators. Organic samples have negligible quench effect in the interval of I concentration of 0-90 {mu}g and inorganic samples only show a very small variation, lower than 12%, for Dioxane-naphthalene, in the same range of concentration. Satisfactory stability is obtained in general for both, organic and inorganic samples, but small counting losses, 0.03% for 19-iodocholesterol 1 I 3-acetate samples in Tolue ne-alcohol and 0 .04% for Na 125I samples in Dioxane-naphthalene and Toluene-alcohol, have been reported. (Author) 8 refs.

  13. [{sup 125}I]{beta}-CIT-FE and [{sup 125}I]{beta}-CIT-FP are superior to [{sup 125}I]{beta}-CIT for dopamine transporter visualization: Autoradiographic evaluation in the human brain

    Energy Technology Data Exchange (ETDEWEB)

    Guenther, Ilonka; Hall, Haakan; Halldin, Christer; Swahn, Carl-Gunnar; Farde, Lars; Sedvall, Goeran

    1997-10-01

    The binding of the three dopamine transporter radioligands ([{sup 125}I]{beta}-CIT, [{sup 125}I]{beta}-CIT-FE, and [{sup 125}I]{beta}-CIT-FP) was studied using whole-hemisphere autoradiography on postmortem human brains. The autoradiograms revealed an intense and homogeneous labeling of the nucleus caudatus and putamen but also to varying extent to serotonergic and noradrenergic transporters of neocortex and thalamus. The order of specificity estimated (striatum over neocortex ratios) was {beta}-CIT-FP > {beta}-CIT-FE >> {beta}-CIT, suggesting that {beta}-CIT-FE and {beta}-CIT-FP should be preferred for in vivo studies of the dopamine transporter in the human brain.

  14. SU-E-T-378: Evaluation of An Analytical Model for the Inter-Seed Attenuation Effect in 103-Pd Multi-Seed Implant Brachytherapy

    Energy Technology Data Exchange (ETDEWEB)

    Safigholi, H; Soliman, A; Song, W [Sunnybrook Research Institute, Sunnybrook Health Sciences Centre, U of T, Toronto, Ontario (Canada); Meigooni, A Soleimani [Comprehensive Cancer Center of Nevada, Las Vegas, Nevada (United States); Han, D [Sunnybrook Research Institute, Sunnybrook Health Sciences Centre, U of T, Toronto, Ontario (Canada); University of California, San Diego, La Jolla, CA (United States)

    2015-06-15

    Purpose: Brachytherapy treatment planning systems based on TG-43 protocol calculate the dose in water and neglects the heterogeneity effect of seeds in multi-seed implant brachytherapy. In this research, the accuracy of a novel analytical model that we propose for the inter-seed attenuation effect (ISA) for 103-Pd seed model is evaluated. Methods: In the analytical model, dose perturbation due to the ISA effect for each seed in an LDR multi-seed implant for 103-Pd is calculated by assuming that the seed of interest is active and the other surrounding seeds are inactive. The cumulative dosimetric effect of all seeds is then summed using the superposition principle. The model is based on pre Monte Carlo (MC) simulated 3D kernels of the dose perturbations caused by the ISA effect. The cumulative ISA effect due to multiple surrounding seeds is obtained by a simple multiplication of the individual ISA effect by each seed, the effect of which is determined by the distance from the seed of interest. This novel algorithm is then compared with full MC water-based simulations (FMCW). Results: The results show that the dose perturbation model we propose is in excellent agreement with the FMCW values for a case with three seeds separated by 1 cm. The average difference of the model and the FMCW simulations was less than 8%±2%. Conclusion: Using the proposed novel analytical ISA effect model, one could expedite the corrections due to the ISA dose perturbation effects during permanent seed 103-Pd brachytherapy planning with minimal increase in time since the model is based on multiplications and superposition. This model can be applied, in principle, to any other brachytherapy seeds. Further work is necessary to validate this model on a more complicated geometry as well.

  15. Comparative study on biodistribution of domestic and imported 125I-β-CIT

    International Nuclear Information System (INIS)

    Liu Xingdang; Lin Xiangtong; Fang Ping; Chen Zhengping; Zhou Xiang; Wang Bocheng; Zhang Manda

    2003-01-01

    Objective: To characterize the kinetics and biodistribution of a domestically synthesized 125 I-2β-carbomethoxy-3β-4-iodopheny1tropane (β-CIT ) and to compare it with that of 125 I-β-CIT imported from RBI company. Methods: 1)The biodistribution of domestic and RBI company produced 125 I-β-CIT in KM mice. Twenty groups of mice (group of 5) were injected into the tail vein with either one of 125 I-β-CIT products. Each group of both products was killed at 5,15,30 and 45 min, and 1, 2, 4, 6, 8 and 24 h. 2)Autoradiography was performed on the brain of SD rats at 2 h after injection. Results: Domestic 125 I-β-CIT was primarily uptaked in the striatum, also in areas rich in 5-HTT such as the brain stem, frontal cortex, parietal cortex, temporal cortex, occipital cortex and hippocampus. Striatal uptake peaked at 2 h postinjection of 125 I-β-CIT. The ratio of specific to nonspecific binding in striatum peaked at 6 h. The highest radioactivity was in the lungs and the less radioactivity was in the liver, kidney, spleen and intestine. Autoradiography confirmed that 125 I-β-CIT primarily bound to striatum and lower room temperature significantly reduced the binding of the agent. Conclusion: The domestic 125 I-β-CIT binds primarily to dopamine transporters in the striatum in mice and rats and the maximum uptake is in the lungs

  16. Dose rate constants for 125I, 103Pd, 192Ir and 169Yb brachytherapy sources: an EGS4 Monte Carlo study

    International Nuclear Information System (INIS)

    Mainegra, Ernesto; Capote, Roberto; Lopez, Ernesto

    1998-01-01

    An exhaustive revision of dosimetry data for 192 Ir, 125 I, 103 Pd and 169 Yb brachytherapy sources has been performed by means of the EGS4 simulation system. The DLC-136/PHOTX cross section library, water molecular form factors, bound Compton scattering and Doppler broadening of the Compton-scattered photon energy were considered in the calculations. The absorbed dose rate per unit contained activity in a medium at 1 cm in water and air-kerma strength per unit contained activity for each seed model were calculated, allowing the dose rate constant (DRC) Λ to be estimated. The influence of the calibration procedure on source strength for low-energy brachytherapy seeds is discussed. Conversion factors for 125 I and 103 Pd seeds to obtain the dose rate in liquid water from the dose rate measured in a solid water phantom with a detector calibrated for dose to water were calculated. A theoretical estimate of the DRC for a 103 Pd model 200 seed equal to 0.669±0.002 cGy h -1 U -1 is obtained. Comparison of obtained DRCs with measured and calculated published results shows agreement within 1.5% for 192 Ir, 169 Yb and 125 I sources. (author)

  17. Method of separating (125I)-L-thyroxine from mixture obtained by radioiodination

    International Nuclear Information System (INIS)

    Mucha, J.; Talan, P.; Dobias, M.

    1982-01-01

    ( 125 I)-L-thyroxine is separated by gel filtration on a column from the mixture of ( 125 I)-L-thyroxine, ( 125 I)-L-3,5,3'-triiodothyronine and ( 125 I) - . The column is packed with a non-polar gel such as polydextran with particle size 25 to 100 μm. The mixture 1,2-propanediol/distilled water/concentrated (26%) aqueous ammonia solution, or 1,2-propanediol/concentrated (26%) aqueous ammonia solution is used as eluent. The concentration of the eluate containing ( 125 I)-L-thyroxine is adjusted with distilled water such as to establish a 50 vol.% concentration of 1,2-propanediol. (E.S.)

  18. Sensitive radioimmunoassay for somatostatin using N-(/sup 125/I)-tyr-somatostatin as labelled antigen

    Energy Technology Data Exchange (ETDEWEB)

    Dupont, A [CHUL, Quebec (Canada). Lab. of Molecular Endocrinology and Service of Gastro-Enterology; Coy, D H; Alvarado-Urbina, G; Cote, J; Meyers, C A; McManus, J; Barden, N; De Lean, A; Labrie, F

    1979-01-01

    A sensitive radioimmunoassay for somatostatin using N-(/sup 125/I)-Tyr-somatostatin is described and compared with using (/sup 125/I)-Tyr/sup 1/-somatostatin. The minimum detectable amount of somatostatin using N-(/sup 125/I)-Tyr-somatostatin as tracer was 0.1 to 0.5 pg, which is approximately 10-fold lower detection limit of the RIA using (/sup 125/I)-Tyr/sup 1/-somatostatin. Moreover, it was found that the shelf-life of N-(/sup 125/I)-Tyr-somatostatin was prolonged in comparison with labelled Tyr/sup 1/-somatostatin. Human pancreatic and gastric extracts displayed immunological similarity to synthetic somatostatin tetradecapeptide.

  19. Biological effects of low energy nitrogen ion implantation on Jatropha curcas L. seed germination

    Energy Technology Data Exchange (ETDEWEB)

    Xu Gang, E-mail: xg335300@yahoo.com.cn [Center for Research and Development of Fine Chemicals, Guizhou University, Guiyang 550025 (China); Institute of Entomology, Guizhou University, Guiyang 550025 (China); Wang Xiaoteng [Department of Agricultural Resources and Environment, College of Agricultural, Guizhou University, Guiyang 550025 (China); Gan Cailing; Fang Yanqiong; Zhang Meng [College of Life Sciences, Guizhou University, Guiyang 550025 (China)

    2012-09-15

    Highlights: Black-Right-Pointing-Pointer We analyzed biological effects of N{sup +} implantation on dry Jatropha curcas seed. Black-Right-Pointing-Pointer N{sup +} implantation greatly decreased seedling survival rate. Black-Right-Pointing-Pointer At doses beyond 15 Multiplication-Sign 10{sup 16} ion cm{sup -2}, biological repair took place. Black-Right-Pointing-Pointer CAT was essential for H{sub 2}O{sub 2} removal. POD mainly functioned as seed was severely hurt. Black-Right-Pointing-Pointer HAsA-GSH cycle mainly contributed to the regeneration of HAsA. - Abstract: To explore the biological effects of nitrogen ion beam implantation on dry Jatropha curcas seed, a beam of N{sup +} with energy of 25 keV was applied to treat the dry seed at six different doses. N{sup +} beam implantation greatly decreased germination rate and seedling survival rate. The doses within the range of 12 Multiplication-Sign 10{sup 16} to 15 Multiplication-Sign 10{sup 16} ions cm{sup -2} severely damaged the seeds: total antioxidant capacity (TAC), germination rate, seedling survival rate, reduced ascorbate acid (HAsA) and reduced glutathione (GSH) contents, and most of the tested antioxidases activity (i.e. catalase (CAT), ascorbate peroxidase (APX) and superoxide dismutase (SOD)) reached their lowest levels. At a dose of 18 Multiplication-Sign 10{sup 16} ion cm{sup -2}, biological repair took place: moderate increases were found in TAC, germination rate, seedling survival rate, HAsA and GSH contents, and some antioxidant enzyme activities (i.e. CAT, APX, SOD and GPX). The dose of 18 Multiplication-Sign 10{sup 16} ions cm{sup -2} may be the optimum dose for use in dry J. curcas seed mutation breeding. CAT, HAsA and GSH contributed to the increase of TAC, but CAT was the most important. POD performed its important role as seed was severely damaged. The main role of the HAsA-GSH cycle appeared to be for regeneration of HAsA.

  20. SLM Produced Porous Titanium Implant Improvements for Enhanced Vascularization and Osteoblast Seeding

    Science.gov (United States)

    Matena, Julia; Petersen, Svea; Gieseke, Matthias; Kampmann, Andreas; Teske, Michael; Beyerbach, Martin; Murua Escobar, Hugo; Haferkamp, Heinz; Gellrich, Nils-Claudius; Nolte, Ingo

    2015-01-01

    To improve well-known titanium implants, pores can be used for increasing bone formation and close bone-implant interface. Selective Laser Melting (SLM) enables the production of any geometry and was used for implant production with 250-µm pore size. The used pore size supports vessel ingrowth, as bone formation is strongly dependent on fast vascularization. Additionally, proangiogenic factors promote implant vascularization. To functionalize the titanium with proangiogenic factors, polycaprolactone (PCL) coating can be used. The following proangiogenic factors were examined: vascular endothelial growth factor (VEGF), high mobility group box 1 (HMGB1) and chemokine (C-X-C motif) ligand 12 (CXCL12). As different surfaces lead to different cell reactions, titanium and PCL coating were compared. The growing into the porous titanium structure of primary osteoblasts was examined by cross sections. Primary osteoblasts seeded on the different surfaces were compared using Live Cell Imaging (LCI). Cross sections showed cells had proliferated, but not migrated after seven days. Although the cell count was lower on titanium PCL implants in LCI, the cell count and cell spreading area development showed promising results for titanium PCL implants. HMGB1 showed the highest migration capacity for stimulating the endothelial cell line. Future perspective would be the incorporation of HMGB1 into PCL polymer for the realization of a slow factor release. PMID:25849656

  1. SLM Produced Porous Titanium Implant Improvements for Enhanced Vascularization and Osteoblast Seeding

    Directory of Open Access Journals (Sweden)

    Julia Matena

    2015-04-01

    Full Text Available To improve well-known titanium implants, pores can be used for increasing bone formation and close bone-implant interface. Selective Laser Melting (SLM enables the production of any geometry and was used for implant production with 250-µm pore size. The used pore size supports vessel ingrowth, as bone formation is strongly dependent on fast vascularization. Additionally, proangiogenic factors promote implant vascularization. To functionalize the titanium with proangiogenic factors, polycaprolactone (PCL coating can be used. The following proangiogenic factors were examined: vascular endothelial growth factor (VEGF, high mobility group box 1 (HMGB1 and chemokine (C-X-C motif ligand 12 (CXCL12. As different surfaces lead to different cell reactions, titanium and PCL coating were compared. The growing into the porous titanium structure of primary osteoblasts was examined by cross sections. Primary osteoblasts seeded on the different surfaces were compared using Live Cell Imaging (LCI. Cross sections showed cells had proliferated, but not migrated after seven days. Although the cell count was lower on titanium PCL implants in LCI, the cell count and cell spreading area development showed promising results for titanium PCL implants. HMGB1 showed the highest migration capacity for stimulating the endothelial cell line. Future perspective would be the incorporation of HMGB1 into PCL polymer for the realization of a slow factor release.

  2. Distribution of implanted ions in seeds and roots of mung bean

    International Nuclear Information System (INIS)

    Liu Donghua; Wang Wei; Jiang Wusheng; Zhang Zhixiang; Hou Wenqiang; Guo Ximing; Li Yi

    1998-01-01

    Doses of 1 x 10 16 , and 2 x 10 16 cm -2 and 1 x 10 16 , 2 x 10 16 , 3 x 10 16 and 3.6 x 10 16 cm -2 for iron and copper ions are implanted in dry seeds of mung bean, respectively. The results show that the accumulated-copper and -iron ion amounts in the seeds and roots vary with different doses of ion beam, and the fresh and dry weights of the roots decrease progressively with increasing iron and copper doses, except the treatment of 1 x 10 16 Cu + ions/cm 2 , and the accumulated-copper and -iron ion amounts in the seeds of the different test groups can be correlated with the ion distribution in the roots

  3. Biological effects of ion implantation on processing tomato and eggplant seed

    International Nuclear Information System (INIS)

    Mao Peihong; Zeng Xianxian; Jin Xiang

    2004-01-01

    The seed of processing tomato '87-5' (Lycopersicon esculentum Mill) were implanted by the low energy nitrogen ion (N + ) with 6 different doses. The rate of emergence was little reduced in M1 generation, but the fruiting number per plant was increased and it's maturing earlier 20 days than the control. The precocity, disease resistance and stronger growth vigor were shown in M2 generation. Experimental results of two years showed that, according to synthetic analysis in factors such as precocity, disease resistance, high yield and quality, the N + dose of 6 x 10 16 cm -2 (60 times of pulse) for tomato seed '87-5' had been proved to have notable biological effects on M1 and M2 generation. The seed of eggplant 'Wuyeqie' (Solanum melongena L.) was also implanted by the low energy nitrogen ion (N + ) with 2 different doses. Multi-vertical channel fruits were obtained in variable M1 generation, which liked the pomelo without peel. The seed of these variable eggplants was taken and planted in the next year. The meaningful variable fruits, the characters of disease-resistance, purple-peel, small-navel, lantern-form, large-scale, etc. were obtained in beneficial M2 generation. The biggest single-fruit weight reached 1.53 kg, providing valuable germplasm resource for breeding. (authors)

  4. Iodine-125 thin seeds decrease prostate swelling during transperineal interstitial permanent prostate brachytherapy

    International Nuclear Information System (INIS)

    Beydoun, Nadine; Bucci, Joseph A.; Chin, Yaw S.; Malouf, David

    2014-01-01

    Prostate swelling following seed implantation is a well-recognised phenomenon. The purpose of this intervention was to assess whether using thinner seeds reduces post-implant swelling with permanent prostate brachytherapy. Eighteen consecutive patients eligible for prostate seed brachytherapy underwent seed implantation using iodine-125 (I-125) thin seeds. Operative time, dosimetry, prostate swelling and toxicity were assessed and compared with standard I-125 stranded seed controls, sourced from the department's brachytherapy database. A learning curve was noted with the thin seeds in terms of greater bending and deviation of needles from their intended path. This translated into significantly longer total operative time (88 vs 103 minutes; P=0.009, 95% confidence interval (CI) 4.1-24.3) and time per needle insertion (2.6 vs 3.7 minutes; P<0.001, 95% CI 0.5-1.3) for the thin seeds. Day 30 prostate volumes were significantly smaller in the thin seed group compared with standard seeds (40.9cc vs 46.8cc; P=0.001, 95% CI 1.5-5.6). The ratio of preoperative transrectal ultrasound to day 30 post-implant CT volume was also smaller in the thin seed group (1.2±0.1 for standard seeds vs 1.1±0.1 for thin seeds). Post-implant dosimetric parameters were comparable for both groups. No significant differences were seen in acute urinary morbidity or quality of life between the two groups. I-125 thin seeds are associated with an initial learning curve, with longer operative time, even for experienced brachytherapists. The significant reduction in day 30 prostate volumes with the thin seeds has useful implications in terms of optimising dose coverage to the prostate in the early period post-implantation, as well as improving the accuracy of post-implant dosimetric assessments.

  5. Optimization of permanent breast seed implant dosimetry incorporating tissue heterogeneity

    Science.gov (United States)

    Mashouf, Shahram

    Seed brachytherapy is currently used for adjuvant radiotherapy of early stage prostate and breast cancer patients. The current standard for calculation of dose around brachytherapy sources is based on the AAPM TG43 formalism, which generates the dose in homogeneous water medium. Recently, AAPM task group no. 186 (TG186) emphasized the importance of accounting for heterogeneities. In this work we introduce an analytical dose calculation algorithm in heterogeneous media using CT images. The advantages over other methods are computational efficiency and the ease of integration into clinical use. An Inhomogeneity Correction Factor (ICF) is introduced as the ratio of absorbed dose in tissue to that in water medium. ICF is a function of tissue properties and independent of the source structure. The ICF is extracted using CT images and the absorbed dose in tissue can then be calculated by multiplying the dose as calculated by the TG43 formalism times ICF. To evaluate the methodology, we compared our results with Monte Carlo simulations as well as experiments in phantoms with known density and atomic compositions. The dose distributions obtained through applying ICF to TG43 protocol agreed very well with those of Monte Carlo simulations and experiments in all phantoms. In all cases, the mean relative error was reduced by at least a factor of two when ICF correction factor was applied to the TG43 protocol. In conclusion we have developed a new analytical dose calculation method, which enables personalized dose calculations in heterogeneous media using CT images. The methodology offers several advantages including the use of standard TG43 formalism, fast calculation time and extraction of the ICF parameters directly from Hounsfield Units. The methodology was implemented into our clinical treatment planning system where a cohort of 140 patients were processed to study the clinical benefits of a heterogeneity corrected dose.

  6. Exploration of dopamine transporter and D2 receptors in morphine dependent rats through 125I-β-CTT, 125I-IBZM cerebral autoradiography and the biodistribution study

    International Nuclear Information System (INIS)

    Lin Yansong; Fang Ping; Ding Shiyu; Chen Zhengping; Zhou Xiang; Hu Mingyang; Wang Bocheng; Zhang Manda; Wang Shizhen

    2001-01-01

    Objective: To explore the variation of cerebral dopamine (DA) transmitting system in morphine dependent (MD) rats using dopamine transporter (DAT) and D 2 receptors imaging agent. Methods: MD model rats were established by using a two-compartment (C1 and C2-morphine conditioned compartment) apparatus for assessing morphine conditioned place preferences in rats. 125 I-2β-carbomethoxy-3β-(4-iodophenyl) tropane ( 125 I-β-CIT) and 125 I-3-iodo-2-hydroxy-6-methoxy-N[(1-ethyl-2-pyrrolidinyl) methyl] benzamide ( 125 I-IBZM) cerebral DAT and D 2 receptor autoradiography and biodistribution study were used to evaluate the variation of DAT and D 2 receptors in morphine dependent rats. Results: The mean time of MD rats entering from C1 to C2 was (0.84 +- 0.50) min after 6 days' conditioned place preference training, shorter than that of the control group [(2.40 +- 1.10) min, P 125 I-β-CIT uptake ratio of striatum (ST)/cerebellum (CB) and nucleus acumens (NAC)/CB in MD group were 4.76 +- 0.92 and 2.72 +- 0.96, significantly lower than that of control group (5.92 +- 0.67 and 4.16 +- 0.56, P 125 I-IBZM uptake ratio in MD group were 4.11 +- 0.56 and 2.64 +- 0.25, lower than that in control group (5.43 +- 0.74 and 3.49 +- 0.65, P 125 I-β-CIT, 125 I-IBZM biodistribution study also showed that the DAT and D 2 binding sites were reduced in ST of MD group by (21.68 +- 11.11)% and (18.69 +- 9.97)% comparing to the controls, respectively. Conclusions: The DAT and D 2 receptors in both ST and NAC were all involved and reduced to some extent in morphine dependent model rats, the DAT and D 2 receptor imaging agent could reflect the variation of DAT and D 2 receptors, this would afford the theoretical basis for D 2 receptors and DAT imaging in study on preventing drug addiction and on its abstinence

  7. (125I)Iodoazidococaine, a photoaffinity label for the haloperidol-sensitive sigma receptor

    International Nuclear Information System (INIS)

    Kahoun, J.R.; Ruoho, A.E.

    1992-01-01

    A carrier-free radioiodinated cocaine photoaffinity label, (-)-3-( 125 I)iodo-4-azidococaine [( 125 I)IACoc], has been synthesized and used as a probe for cocaine-binding proteins. Photoaffinity labeling with 0.5 nM ( 125 I)IACoc resulted in selective derivatization of a 26-kDa polypeptide with the pharmacology of a sigma receptor in membranes derived from whole rat brain, rat liver, and human placenta. ( 125 I)IACoc labeling of the 26-kDa polypeptide was also inhibited by 10 μM imipramine, amitriptyline, fluoxetine, benztropine, and tetrabenazine. The size of the ( 125 I)I-ACoc-labeled proteins is consistent with the size of proteins photolabeled in guinea pig brain and liver membranes by using the sigma photolabel azido-[ 3 H]DTG. Kinetic analysis of ( 125 I)IACoc binding to rat liver microsomes revealed two sites with K d values of 19 and 126 pM, respectively. The presence or absence of proteolytic inhibitors during membrane preparation did not alter the size of the photolabeled sigma receptor, indicating that the 26-kDa polypeptide was not derived from a larger protein. In summary, ( 125 I)IACoc is a potent and highly specific photoaffinity label for the haloperidol-sensitive sigma receptor and will be useful for its biochemical and molecular characterization

  8. SU-F-19A-11: Retrospective Evaluation of Thermal Coverage by Thermobrachytherapy Seed Arrangements of Clinical LDR Prostate Implants

    Energy Technology Data Exchange (ETDEWEB)

    Warrell, G; Shvydka, D; Chen, C; Parsai, E [University of Toledo Medical Center, Toledo, OH (United States)

    2014-06-15

    Purpose: The superiority of a properly-administered combination of radiation therapy and hyperthermia over radiation alone in treatment of human cancers has been demonstrated in multiple studies examining radiobiology, local control, and survival. Unfortunately, hyperthermia is not yet a common modality in oncology practice, due in part to the technical difficulty of heating a deep-seated target volume to sufficient temperature. To address this problem, our group has invented a thermobrachytherapy (TB) seed based on a commonly-used low dose-rate permanent brachytherapy seed for implant in solid tumors. Instead of the tungsten radiographic marker of the standard seed, the TB seed contains one of a self-regulating ferromagnetic alloy. Placement of a patient implanted with such seeds in an oscillating magnetic field generates heat via induction of eddy currents. We present the results of studies of the capability of clinically-realistic TB seed arrangements to adequately heat defined target volumes. Methods: Seed distributions for several past LDR prostate permanent implant brachytherapy patients were reproduced in the finite element analysis software package COMSOL Multiphysics 4.4, with the difference that TB seeds were modelled, rather than the radiation-only seeds actually used for their treatments. The implant geometries were mainly of the modified peripheral loading type; a range of prostatic volumes and blood perfusion rates likely to be seen in a clinical setting were examined. Results: According to the simulations, when distributed to optimize radiation dose, TB seeds also produce sufficient heat to provide thermal coverage of the target given proper selection of the magnetic field strength. However, the thermal distributions may be improved by additional use of hyperthermia-only seeds. Conclusion: A dual-modality seed intended as an alternative to and using the same implantation apparatus and technique as the standard LDR permanent implant seed has been

  9. Studies with encapsulated 125I sources: dosimetry for determination of relative biological effectiveness

    International Nuclear Information System (INIS)

    Goldhagen, P.; Freeman, M.L.; Hall, E.J.

    1981-01-01

    During the past year, members of this laboratory have measured the Relative Biological Effectiveness (RBE) of photons from encapsulated 125 I sources (mean energy = 28.33 keV) using 661.6 keV 137 Cs gamma rays as a standard for comparison. These experiments were performed at clinically relevant dose rates and used reduction of the reproductive viability of mammalian cells as an endpoint. This section will discuss how dosimetry problems special to 125 I influence the design of the apparatus and will describe the ionization chamber to be used for measuring dose rates from both 125 I and 137 Cs photons

  10. Variation in 125I-Insulin absorption and blood glucose concentration

    International Nuclear Information System (INIS)

    Lauritzen, T.; Faber, O.K.; Binder, C.

    1979-01-01

    The absorption of monocomponent porcine 125 I-insulin Monotard and Isophane was studied in six insulin dependent diabetic patients over a period of 12 days. The absorption of insulin was measured as the disappearance of radioactivity from sites of injection. The daily 125 I-insulin doses ranged from 20 to 48 IU between patients. The insulin absorbed varied considerably within and between patients. The range of individual daily absorbed insulin varied from 19 to 104 per cent of the 125 I-insulin dose. A significant correlation (p [de

  11. Effect of fentanyl on 125I-β-CIT uptake in mice brain

    International Nuclear Information System (INIS)

    Liu Xingdang; Lin Xiangtong

    2003-01-01

    Objective: To investigate the effect of fentanyl on 125 I-2β-carbomethoxy-3β-(4-iodophenyl) tropane ( 125 I-β-CIT) uptake in mice brain. Methods: 1) KM mice groups of five were given different doses of fentanyl, and 10 min or 1 h later were given a dose of 125 I-β-CIT. 2)Two groups of animals were killed at 2 h after injection of 125 I-β-CIT. 3)One group of animals were killed at 1 h after injection of 125 I-β-CIT. Results: 1)In the striatum, frontal cortex, hippocampus, brain stem, cerebellum and whole brain, a dose-dependent increase in uptake (%ID/g or %ID) of 125 I-β-CIT was detected at the fentanyl doses ranging from 125 to 300 μg/kg, and the uptakes of hippocampus and cerebellum were higher than that of the controls. There was a great difference in the value of %ID/g or %ID between the group treated with 250 μg/kg fentanyl and the control group; while at the doses from 12.5 to 100 μg/kg, a dose-dependent decrease in uptake in the same regions was observed and all the uptake levels were lower (hippocampus: except 62.5 and 12.5 μg/kg groups; brain stem: except 62.5 μg/kg group) than that of the controls. 2)The uptakes of 125 I-β-CIT in the striatum, frontal cortex, hippocampus, brain stem, cerebellum and whole brain in the groups injected with 125 I-β-CIT 10 min after fentanyl treatment were higher than that in the groups injected with 125 I-β-CIT 1 h after fentanyl treatment. 3)The binding of 125 I-β-CIT in the striatum, frontal cortex, hippocampus, brain stem, cerebellum and whole brain in the groups killed at 1 h after injection of 125 I-β-CIT was higher than that in the control group, but without significant difference. Conclusion: Fentanyl may have different effects on 125 I-β-CIT at various time points and doses

  12. In vivo study about specific captation of 125 I-insulin by rat brain structures

    International Nuclear Information System (INIS)

    Sanvitto, G.L.

    1986-01-01

    The specific captation of 125 I-insulin was evaluated by brain structures, as olfactory bulbous, hypothalamus and cerebellum in rats, from in vivo experiences that including two different aspects: captation measure of 125 I-insulin after the intravenous injection of the labelled hormone, in fed rats and in rats with 48 h of fast or convulsion, procedure by the pentylene tetrazole; captation measure of 125 I-insulin after intra-cerebral-ventricular injection of the labelled hormone in fed rats. (C.G.C.)

  13. m-[125I]iodoaniline: a useful reagent for radiolabeling biotin

    International Nuclear Information System (INIS)

    Khawli, L.A.; Kassis, A.I.

    1992-01-01

    Biotinyl-m-[ 125 I]iodoanilide (BIA) was synthesized by coupling biotin to m-[ 125 I]iodoaniline via a mixed anhydride reaction. m-[ 125 I]Iodoaniline was produced from the tin precursor, which was prepared using a palladium catalyzed reaction of hexabutylditin with m-bromoaniline. The radioiodinated BIA derivative is characterized by a stable amide and/or intact ureido group on the biotin molecule, it may thus be a useful carrier for targeting radionuclides to avidin-conjugated antibodies previously localized on tumors. (author)

  14. Distribution and levels of [125I]IGF-I, [125I]IGF-II and [125I]insulin receptor binding sites in the hippocampus of aged memory-unimpaired and -impaired rats

    International Nuclear Information System (INIS)

    Quirion, R.; Rowe, W.; Kar, S.; Dore, S.

    1997-01-01

    The insulin-like growth factors (IGF-I and IGF-II) and insulin are localized within distinct brain regions and their respective functions are mediated by specific membrane receptors. High densities of binding sites for these growth factors are discretely and differentially distributed throughout the brain, with prominent levels localized to the hippocampal formation. IGFs and insulin, in addition to their growth promoting actions, are considered to play important roles in the development and maintenance of normal cell functions throughout life. We compared the anatomical distribution and levels of IGF and insulin receptors in young (five month) and aged (25 month) memory-impaired and memory-unimpaired male Long-Evans rats as determined in the Morris water maze task in order to determine if alterations in IGF and insulin activity may be related to the emergence of cognitive deficits in the aged memory-impaired rat. In the hippocampus, [ 125 I]IGF-I receptors are concentrated primarily in the dentate gyrus (DG) and the CA3 sub-field while high amounts of [ 125 I]IGF-II binding sites are localized to the pyramidal cell layer, and the granular cell layer of the DG. [ 125 I]insulin binding sites are mostly found in the molecular layer of the DG and the CA1 sub-field. No significant differences were found in [ 125 I]IGF-I, [ 125 I]IGF-II or [ 125 I]insulin binding levels in any regions or laminae of the hippocampus of young vs aged rats, and deficits in cognitive performance did not relate to altered levels of these receptors in aged memory-impaired vs aged memory-unimpaired rats. Other regions, including various cortical areas, were also examined and failed to reveal any significant differences between the three groups studied.It thus appears that IGF-I, IGF-II and insulin receptor sites are not markedly altered during the normal ageing process in the Long-Evans rat, in spite of significant learning deficits in a sub-group (memory-impaired) of aged animals. Hence

  15. Gamma spectrometry and chemical characterization of bioactive glass seeds with Holmium-166 for oncological implants

    International Nuclear Information System (INIS)

    Valente, Eduardo S.

    2009-01-01

    Bioactive glass seeds synthesized by the sol-gel technique with Si:Ho:Ca composition with natural holmium incorporated were irradiated in the TRIGA type nuclear reactor IPR-R1 at 100kW, in the central thimble where the thermal neutron flux is 2.8x10 12 n/cm 2 .s and the epithermal neutron flux is 2.6 X 10 11 n/cm 2 .s . After an 8 hour irradiation time, with an induced activity close to 110MBq/seed, a set of seeds was submitted to Gamma Spectrometry Analysis in a counting system with an HPGe detector, ORTEC electronic instrumentation and a Camberra Multichannel Analyser, to determine all radionuclides present on the sample as well as its individual activities. Special attention was paid on the discrimination of Si, 40 Ca, 44 Ca, C and Ho as the other expected elements like 48 Ca, 2 H and 18 O were present in traces or have very short half-lives. The second sample was submitted to Plasma spectrometry to determine the 166 Ho concentration in weight. The third sample was submitted to an X-ray spectrometry in a JEOL-JXA-8900RL equipment to determine its qualitative chemical composition, in order to evaluate impurities and nominal composition. It was determined that most of the activity, after decaying of short half-life elements, was due to 166 Ho present on the sample, with a well characterized β and gamma spectra. The homogeneity of the seeds was tested on the X-ray spectrometry, and verified that there is no discrepancy in composition from distinct seeds or in a same seed. The results are relevant on the investigation of the viability of producing 166 Ho radioactive seeds for oncological implants. (author)

  16. Computed tomographic-guided iodine-125 interstitial implants for malignant thoracic tumors

    Energy Technology Data Exchange (ETDEWEB)

    Huang, Qiming [The Department of Radiology, First Affiliated Hospital of Fujian Medical University, 20 Chazhong Road, Fuzhou 350005 (China); The Department of Radiology, Second Affiliated Hospital of Fujian Medical University, 34 Zhongshan Bei Road, Quanzhou 362000 (China); Chen, Jin; Chen, Qunlin [The Department of Radiology, First Affiliated Hospital of Fujian Medical University, 20 Chazhong Road, Fuzhou 350005 (China); Lai, Qingquan; Cai, Siqing [The Department of Radiology, Second Affiliated Hospital of Fujian Medical University, 34 Zhongshan Bei Road, Quanzhou 362000 (China); Luo, Kaidong [The Department of Radiology, Longyan Hosptial of Traditional Chinese Medical, 59 Longteng Middle Road, Longyan 364000 (China); Lin, Zhengyu, E-mail: linsinlan@yahoo.com.cn [The Department of Radiology, First Affiliated Hospital of Fujian Medical University, 20 Chazhong Road, Fuzhou 350005 (China)

    2013-11-01

    Purpose: To evaluate the feasibility and efficacy of percutaneous interstitial brachytherapy using iodine-125 ({sup 125}I) radioactive seeds under computed tomographic (CT) guidance for malignant thoracic tumors. Materials and methods: Forty-one patients (34 males, 7 females; 18–90 years; mean, 63.7 years) with 77 lesions (3 in the mediastinum, 7 in the chest wall, 67 in the lung) underwent percutaneous interstitial implantation of {sup 125}I radioactive seeds under CT guidance. A treatment planning system (TPS) was employed to calculate the number and distribution of seeds preoperatively. An 18-G needle was inserted into the lesions under CT guidance and send the seeds according to TPS. Two patients with mediastinal lesions undergoing seed implantation received an artificial pneumothorax. One patient with lung carcinoma adjacent to the anterior mediastinum underwent seed implantation through the sternum. Follow-up CT was done every 2 months postoperatively. Results: The procedure was successful in all patients. No major procedure-associated death occurred. The mean duration of follow-up was 19.4 ± 1.3 months (3–49 months). A complete response (CR) was seen in 49 lesions (63.6%), partial response (PR) in 9 lesions (11.7%), stable disease (SD) in 12 lesions (12.8%), and progressive disease (PD) in 7 lesions (7.4%). The overall response rate (CR + PR) was 75.3%; the local control rate (CR + PR + SD) was 90.9%. The 1-, 2- and 3-year progression-free rates for local tumors were 91%, 88% and 88%, respectively. The 1-, 2- and 3-year survival rates were 87%, 74% and 68%, respectively. Conclusion: Implantation of CT-guided {sup 125}I seeds is feasible and effective for patients with malignant thoracic tumors.

  17. SU-F-T-653: Radiation Exposure from Cs-131 Permanent Seed Implants

    Energy Technology Data Exchange (ETDEWEB)

    Giaddui, T; Hardin, M; To, D; Kremmel, E; Peng, C; Hann, P; Richardson, S; Yu, Y; Harrison, A; Doyle, L [Sidney Kimmel Cancer Center, Thomas Jefferson University, Philadelphia, PA (United States)

    2016-06-15

    Purpose: Permanent seed implants have traditionally been used to treat prostate, lung and head or neck cancers using I-125 and Pd-103. Cs-131, which has higher dose rate is being used to treat brain, head and/or neck cancers in our clinic, therefore, we chose to monitor the dose received by surgeons during the extensive procedure. The aims of this work are to assess the level of radiation exposure to surgeons and the instantaneous exposure at bedside and 1 m from patients. Methods: Ten patients received Cs-131 implants for recurrent brain,head and/or neck cancer; the median implanted activity, number of implanted seeds and prescription dose at 0.5 cm from the perpendicular plane of the implant were: 54.3 mCi (14.52 – 77); 19 (4 – 24) and 60 Gy (range 42 – 60) respectively. Radiation exposure was recorded at bedside and 1 m from the patient using Victoreen ion chamber (Fluke Biomedical, Cleveland, OH). Exposure to surgeons was measured using TLD (Mirion Technologies (GDS), Inc., USA). Results: The median equivalent dose rate at 1 m and bedside immediately following implantation were 1.49×10-2 mSv/h (8.77×10-3–2.63×10-2) and 7.76×10-2 mSv/h (3.1×10-2– 1.53×10-1) respectively. Median equivalent dose to surgeons’ hands was 0.60 mSv (0.33 – 1.48) and no doses were detected for whole-body. Surgical reconstruction for one patient was performed 71 days post-implant and resulted in zero exposure to surgeons. Conclusion: The recorded exposure rates were low when compared with the literature. Post procedure surveys at bed site and 1 m indicated that all patients were within safe limits for discharge (< 0.05 mSv/h at 1 m). However, as a precautionary measure, patients were advised to avoid direct contact with children and pregnant women within four weeks of the implant and stay at least at 3 ft from other people. Surgeons doses were well within occupational dose limits.

  18. Seeding of silicon by copper ion implantation for selective electroless copper plating

    Energy Technology Data Exchange (ETDEWEB)

    Bhansali, S; Sood, D K; Zmood, R B [Microelectronic and Materials Technology Centre, Royal Melbourne Institute of Technolgy, Melbourne, VIC (Australia)

    1994-12-31

    We report on the successful use of copper(self) ion implantation into silicon to seed the electroless plating of copper on silicon (100) surfaces. Copper ions have been implanted to doses of 5E14-6.4E16 ions/cm{sup 2} using a MEEVA ion implanter at extraction voltage of 40kV. Dose was varied in fine steps to determine the threshold dose of 2E15 Cu ions/cm{sup 2} for `seed` formation of copper films on silicon using a commercial electroless plating solution. Plated films were studied with Rutherford backscattering spectrometry, scanning electron microscopy, EDX and profilometry . The adhesion of films was measured by `scotch tape test`. The adhesion was found to improve with increasing dose. However thicker films exhibited rather poor adhesion and high internal stress. SEM results show that the films grow first as isolated islands which become larger and eventually impinge into a continuous film as the plating time is increased. (authors). 5 refs., 1 tab., 3 figs.

  19. Seeding of silicon by copper ion implantation for selective electroless copper plating

    Energy Technology Data Exchange (ETDEWEB)

    Bhansali, S.; Sood, D.K.; Zmood, R.B. [Microelectronic and Materials Technology Centre, Royal Melbourne Institute of Technolgy, Melbourne, VIC (Australia)

    1993-12-31

    We report on the successful use of copper(self) ion implantation into silicon to seed the electroless plating of copper on silicon (100) surfaces. Copper ions have been implanted to doses of 5E14-6.4E16 ions/cm{sup 2} using a MEEVA ion implanter at extraction voltage of 40kV. Dose was varied in fine steps to determine the threshold dose of 2E15 Cu ions/cm{sup 2} for `seed` formation of copper films on silicon using a commercial electroless plating solution. Plated films were studied with Rutherford backscattering spectrometry, scanning electron microscopy, EDX and profilometry . The adhesion of films was measured by `scotch tape test`. The adhesion was found to improve with increasing dose. However thicker films exhibited rather poor adhesion and high internal stress. SEM results show that the films grow first as isolated islands which become larger and eventually impinge into a continuous film as the plating time is increased. (authors). 5 refs., 1 tab., 3 figs.

  20. Seeding of silicon by copper ion implantation for selective electroless copper plating

    International Nuclear Information System (INIS)

    Bhansali, S.; Sood, D.K.; Zmood, R.B.

    1993-01-01

    We report on the successful use of copper(self) ion implantation into silicon to seed the electroless plating of copper on silicon (100) surfaces. Copper ions have been implanted to doses of 5E14-6.4E16 ions/cm 2 using a MEEVA ion implanter at extraction voltage of 40kV. Dose was varied in fine steps to determine the threshold dose of 2E15 Cu ions/cm 2 for 'seed' formation of copper films on silicon using a commercial electroless plating solution. Plated films were studied with Rutherford backscattering spectrometry, scanning electron microscopy, EDX and profilometry . The adhesion of films was measured by 'scotch tape test'. The adhesion was found to improve with increasing dose. However thicker films exhibited rather poor adhesion and high internal stress. SEM results show that the films grow first as isolated islands which become larger and eventually impinge into a continuous film as the plating time is increased. (authors). 5 refs., 1 tab., 3 figs

  1. Side effects of permanent I125 prostate seed implants in 667 patients treated in Leeds

    International Nuclear Information System (INIS)

    Bottomley, David; Ash, Dan; Al-Qaisieh, Bashar; Carey, Brendan; Joseph, Joji; St Clair, Shaun; Gould, Kathy

    2007-01-01

    Purpose: To report the side effects and complications after I-125 seeds prostate implant after 8.5 years experience. Methods and materials: Six hundred and sixty seven (667) patients were treated between March 1995 and December 2001. The median follow up is 31 months with a maximum of 98.2 months. Morbidity data were collected from a review of patient case-notes. Patients also provided prospective data on urinary symptoms using the International Prostate Symptom Score (IPSS) scoring chart before treatment and at regular follow up. Patients were also sent a questionnaire detailing symptoms and side effects following their brachytherapy. This enabled them to record urinary, bowel and sexual function side effects independently. Logistic regression analysis was carried out to identify the risk of catheterisation in relation to the pre-implant prostate volume and potential implant factors such as the number of seeds and needles and implant dose. Result: The urinary symptom score rises in the first few months after implantation and returns to within one or two points of the pre-treatment score within one year. Nine patients reported incontinence prior to treatment and 15, 12 and 10 patients reported incontinence 6, 12 and 24 months after treatment, respectively. Catheterisation was reported in 97 (14.5%) patients. At six months 84.9% of patients reported no change in bowel function and 78.9% at 12 months. 6.4% of patients complained of some increased bowel frequency at 6 months and 5.7% at 12 months. 402 (77.2%) patients reported being fully potent before treatment and that this fell to 32.4% after treatment. Logistic regression showed that the most significant factors which correlate with the probability of catheterisation are the pre-treatment prostate volume and the number of seeds and needles implanted. Conclusion: The side effects and complications after prostate brachytherapy as reported here and elsewhere confirm that the treatment is not only convenient but also

  2. Dosimetric response of radioactive bio glass seeds implants on rabbit brain; Resposta radiodosimetrica de implantes de sementes de biovidros radioativos no cerebro de coelhos

    Energy Technology Data Exchange (ETDEWEB)

    Costa, I.T.; Campos, T.P.R., E-mail: itemponi@yahoo.com.br, E-mail: campos@nuclear.ufmg.br [Programa de Pos-Graduacao em Ciencias e Tecnicas Nucleares - Universidade Federal de Minas Gerais, Belo Horizonte, MG (Brazil)

    2007-07-01

    Interstitial implants of radioactive seeds are used as an efficient way of treating brain tumors. Bio glasses is an interesting alternative to the metallic implanted materials, because they can be absorbed by the organism, reducing the possibilities of side effects. The present paper investigates the dosimetry by the implants performed on rabbit's brain on the NRI/UFMG research group. The spatial distribution of the specific ionizing energy deposited per unit of mass generated by Sm-153 seeds were evaluated. A computational model of the brain's region was built using the software SISCODES produced by the research group. The sections of the computer tomography of a rabbit, which was included on the experiment, were digitalized. Those were converted in a three dimensional voxel model, including the tissues, its chemical composition and density. A simulation of the particles transport is performed by the stochastic code MCNP5. The implants consist of 15 ceramic Ca-Si-Sm seeds enriched with Sm-153, with 1.1.6 mm of length and 0.3 mm diameter, implanted on the rabbit's brain. It was predicted on the model three ribbons of 5 seeds each, spaced by 1.1.2 mm, since the ribbons were in a triangular topology whose vertices were spaced by 8 mm. The activities were 120 MBq/seed. The results show isodose regions superposed over the rabbits' model, reproducing the spatial energy deposition on the brain region. The absorbed dose predicted was 3.2 Gy per 15 seed; however it was not enough to tumor control. The authors suggest to increase the number of seeds and activity, reduction of the space to 5-6 mm among ribbons, improving dose with the beta emitting. (author)

  3. In vitro cell-mediated immunity assay using 125I-iododeoxyuridine

    International Nuclear Information System (INIS)

    Morris, J.E.; Graham, T.M.

    1979-01-01

    We investigated an in vitro cell-mediated immunity assay using incorporation of 125 I-iododeoxyuridine as an indicator of lymphocyte responsiveness to mitogen stimulation. The system permits the use of whole-blood cultures in rats and dogs

  4. Report of a minor 125I exposure in a research laboratory

    International Nuclear Information System (INIS)

    Lambert, J.P.

    1981-01-01

    In routine thyroid scanning of personnel whose work involved the use of 125 I in biological research, it was discovered that an individual who had been iodinating proteins periodically for over 6 months showed a high thyroid count rate. It was decided to monitor the individual's thyroid weekly and to curtail his work in the laboratory until the cause of the thyroid uptake could be determined. Initially the 125 I concentration in his thyroid decreased as expected but a subsequent scan on the 21st day showed an 125 I concentration even greater than the initial level despite his absence from the laboratory. However on monitoring his office space, it was discovered that a felt pen was grossly contaminated and that the individual habitually put the pen in his mouth during moments of cogitation. It was concluded that a contaminated glove had transferred some 125 I to the pen during the course of the experiment. (U.K.)

  5. Study of o-125I-benzoate excretion mechanisms in the rabbit

    International Nuclear Information System (INIS)

    Richter, R.; Laznicek, M.; Kvetina, J.; Laznickova, A.

    1990-01-01

    An analysis of the mechanisms of renal clearance of o- 125 I-benzoate in the rabbit based on the inhibition of the secretory transport by probenecid showed that o- 125 I-benzoate was eliminated in the kidneys not only by glomerular filtration but also by tubular secretion. The total amount of the drug excreted in the urine was affected by tubular resorption (apparently by the process of passive diffusion), which exceeded tubular secretion. A comparison of the chromatograms of the plasma and the urine before and after the competitive inhibition of the tubular active transport by probenecid revealed a higher amount of o- 125 I-benzoylglucuronide in the urine in the case of inhibition. The results suggest that the kidneys participated in the total biotransformation of o- 125 I-benzoate. The excretion of the original drug and metabolites in the bile contributed less than 1% to the total clearance in rabbits. (author). 3 figs., 3 tabs., 10 refs

  6. Proteolytic activity of beef liver determined by natural /sup 125/I-labelled substrates

    Energy Technology Data Exchange (ETDEWEB)

    Blahovec, J; Ondrus, I [Vysoka Skola Veterinarska, Kosice (Czechoslovakia)

    1975-07-01

    The method of determining the enzymatic activity of acid proteinases is described. The method is based on the use of /sup 125/I-labelled natural protein substrates. /sup 125/I-labelled albumin, /sup 125/I-globulin and /sup 125/I-insulin were tested for the determination of activities. All the substrates were hydrolyzed with the enzymes of the supernatant fraction (106,000 g) of beef liver homogenate in the acid pH zone. Optimum enzymatic reaction conditions were tested, the dependence of the reaction on the enzyme concentration, time and temperature was determined, pH optimum was ascertained for the individual substrates, and pH stability was determined. The results show that the method is suitable for determining the enzymatic activity of proteinases of cathepsin character.

  7. Inhibition effects of 125I-triplex forming oligonucleotide to hepatoma cells

    International Nuclear Information System (INIS)

    Lv Zhongwei; Hou Min; Cai Haidong; Yuan Xueyu; Yang Yuehua; Yuan Shidong; He Junmin

    2007-01-01

    Objective: Triplex forming oligonucleotide (TFO) has been reported as a new antigene strategy. The purpose of this study was to observe the inhibition effects of 125 I-TFO on hepatoma cells and to investigate the possibility of using 125 I-TFO as an antigene radiotherapy technique for hepatocellular carcinoma (HCC) related to HBV. Methods: TFO complementary to the initiator of S gene of HBV was synthesized and labeled with 125 I. HepG2.2.15 cells, in which HBV genome was integrated, were incubated with 125 I-TFO, TFO and 125 I respectively. After incubation, hepatitis B e antigen (HBeAg) and hepatitis B surface antigen (HBsAg) of each group were assayed with ELISA and the survival rate of cells in each group was determined with 3-(4,5-dimethylthiazol-2-yl)-2,5-diphenylte-trazolium bromide (MTT) reduction assay. Results: 125 I-TFO showed a high stability with a radiolabeling rate of >93%. The radiochemical purity of labeled compound was 90.8%, 81.1% and 73.2% respectively after 12, 48 and 72 h at 37 degree C. The peak inhibition effect of 125 I-TFO on synthesizing HBsAg and HBeAg by HepG2.2.15 cells were found at 48 h after transfection, with significantly the highest inhibition rate of 45.2% for HBsAg and 74.5% for HBeAg expression among the three groups(P 125 I-TFO may inhibit the antigen expression of HBV and the growth of hepatocarcinoma cells, thus it may provide a new approach to develop gene-based radiotherapeutic pharmaceuticals for anti-HBV and HCC. (authors)

  8. Selective binding of 2-[125I]iodo-nisoxetine to norepinephrine transporters in the brain

    International Nuclear Information System (INIS)

    Kung, M.-P.; Choi, Seok-Rye; Hou, Catherine; Zhuang, Z.-P.; Foulon, Catherine; Kung, Hank F.

    2004-01-01

    A radioiodinated ligand, (R)-N-methyl-(2-[ 125 I]iodo-phenoxy)-3-phenylpropylamine, [ 125 I]2-INXT, targeting norepinephrine transporters (NET), was successfully prepared. A no-carrier-added product, [ 125 I]2-INXT, displayed a saturable binding with a high affinity (K d =0.06 nM) in the homogenates prepared from rat cortical tissues as well as from LLC-PK 1 cells expressing NET. A relatively low number of binding sties (B max =55 fmol/mg protein) measured with [ 125 I]2-INXT in rat cortical homogenates is consistent with the value reported for a known NET ligand, [ 3 H]nisoxetine. Competition studies with various compounds on [ 125 I]2-INXT binding clearly confirmed the pharmacological specificity and selectivity for NET binding sites. Following a tail-vein injection of [ 125 I]2-INXT in rats, a good initial brain uptake was observed (0.56% dose at 2 min) followed by a slow washout from the brain (0.2% remained at 3 hours post-injection). The hypothalamus (a NET-rich region) to striatum (a region devoid of NET) ratio was 1.5 at 3 hours post-i.v. injection. Pretreatment of rats with nisoxetine significantly inhibited the uptake of [ 125 I]2-INXT (70-100% inhibition) in locus coeruleus, hypothalamus and raphe nuclei, regions known to have a high density of NET; whereas escitalopram, a serotonin transporter ligand, did not show a similar effect. Ex vivo autoradiography of rat brain sections of [ 125 I]2-INXT (at 3 hours after an i.v. injection) displayed an excellent regional brain localization pattern corroborated to the specific NET distribution in the brain. The specific brain localization was significantly reduced by a dose of nisoxetine pretreatment. Taken together, the data suggest that [ 123 I]2-INXT may be useful for mapping NET binding sites in the brain

  9. Microchemical synthesis of the serotonin receptor ligand, 125I-LSD

    International Nuclear Information System (INIS)

    Hartig, P.R.; Krohn, A.M.; Hirschman, S.A.

    1985-01-01

    The synthesis and properties of 2-[ 125 I]-lysergic acid diethylamide, the first 125 I-labeled serotonin receptor ligand, are described. A novel microsynthesis apparatus was developed for this synthesis. The apparatus employs a micromanipulator and glass micro tools to handle microliter to nanoliter volumes on a microscope stage. This apparatus should be generally useful for the synthesis of radioligands and other compounds when limited amounts of material must be handled in small volumes

  10. Biodistribution analysis of 125I-albumin-IFN-alpha2b fusion protein in rats

    International Nuclear Information System (INIS)

    Zhou Yaoyuan; Zhang Rongjun; Cai Gangming; Gu Xiaobo; Jiang Mengjun; Zhang Bo; Yang Min; Cao Guoxian; Yang Jianliang

    2009-01-01

    125 I-albumin-IFN-alpha2b was prepared with the methods of Ch-T and purified with PD-10 column. The radiochemical purity was measured with TCA (trichloroacetic acid) precipitation. The antiviral activities of 125 I-albumin-IFN-alpha2b and albumin-IFN-alpha2b were compared with WISH/VSV system in vitro. SD rats were injected with 125 I-albumin-IFN-alpha2b subcutaneously and sacrificed at 0.5, 2, 6, 24, 48, 90, 180 and 300 h post-injection. Selected organs were dissected, weighed and their radioactivity was measured using γ-counter. The accumulated radioactivity in the tissues was calculated in terms of percentage of injected dose per gram organ (%ID·g -1 ). The labeling yield was 82.72%. The radiochemical purity of 125 I-albumin-IFN-alpha2b was 95.53%, and its radioactivity was 0.26 MBq/μg. The antiviral bioactivities of albumin-IFN-alpha2b and 125 I-albumin- IFN-alpha2b did not change. Biodistribution analysis of 125 I-albumin-IFN-alpha2b in rats showed that concentrated 125 I-albumin-IFN-alpha2b in blood reached maximum at 6 h post injection, and eliminated slowly. No specific accumulation was seen in other tissues. 125 I-albumin-IFN-alpha2b could maintain in peripheral blood for a long time and it meant albumin-IFN-alpha2b would be an effective long-term interferon. (authors)

  11. Inhibition effects of {sup 125}I-triplex forming oligonucleotide to hepatoma cells

    Energy Technology Data Exchange (ETDEWEB)

    Zhongwei, Lv; Min, Hou; Haidong, Cai; Xueyu, Yuan; Yuehua, Yang; Shidong, Yuan [Department of Nuclear Medicine, 10th People' s Hospital, Tongji Univ., Shanghai (China); Junmin, He

    2007-08-15

    Objective: Triplex forming oligonucleotide (TFO) has been reported as a new antigene strategy. The purpose of this study was to observe the inhibition effects of {sup 125}I-TFO on hepatoma cells and to investigate the possibility of using {sup 125}I-TFO as an antigene radiotherapy technique for hepatocellular carcinoma (HCC) related to HBV. Methods: TFO complementary to the initiator of S gene of HBV was synthesized and labeled with {sup 125}I. HepG2.2.15 cells, in which HBV genome was integrated, were incubated with {sup 125}I-TFO, TFO and {sup 125}I respectively. After incubation, hepatitis B e antigen (HBeAg) and hepatitis B surface antigen (HBsAg) of each group were assayed with ELISA and the survival rate of cells in each group was determined with 3-(4,5-dimethylthiazol-2-yl)-2,5-diphenylte-trazolium bromide (MTT) reduction assay. Results: {sup 125}I-TFO showed a high stability with a radiolabeling rate of >93%. The radiochemical purity of labeled compound was 90.8%, 81.1% and 73.2% respectively after 12, 48 and 72 h at 37 degree C. The peak inhibition effect of {sup 125}I-TFO on synthesizing HBsAg and HBeAg by HepG2.2.15 cells were found at 48 h after transfection, with significantly the highest inhibition rate of 45.2% for HBsAg and 74.5% for HBeAg expression among the three groups(P<0.01 ). As the transfection time prolonged its inhibition effects were stronger. Conclusion: {sup 125}I-TFO may inhibit the antigen expression of HBV and the growth of hepatocarcinoma cells, thus it may provide a new approach to develop gene-based radiotherapeutic pharmaceuticals for anti-HBV and HCC. (authors)

  12. Radial dose functions for 103Pd, 125I, 169Yb and 192Ir brachytherapy sources: an EGS4 Monte Carlo study

    International Nuclear Information System (INIS)

    Mainegra, E.

    2000-01-01

    Radial dose functions g(r) in water around 103 Pd, 125 I, 169 Yb and 192 Ir brachytherapy sources were estimated by means of the EGS4 simulation system and extensively compared with experimental as well as with theoretical results. The DLC-136/PHOTX cross section library, water molecular form factors, bound Compton scattering and Doppler broadening of the Compton-scattered photon energy were considered in the calculations. Use of the point source approach produces reasonably accurate values of the radial dose function only at distances beyond 0.5 cm for 103 Pd sources. It is shown that binding corrections for Compton scattering have a negligible effect on radial dose function for 169 Yb and 192 Ir seeds and for 103 Pd seeds under 5.0 cm from the source centre and for the 125 I seed model 6702 under 8.0 cm. Beyond those limits there is an increasing influence of binding corrections on radial dose function for 103 Pd and 125 I sources. Results in solid water medium underestimate radial dose function for low-energy sources by as much as 6% for 103 Pd and 2.5% for 125 I already at 2 cm from source centre resulting in a direct underestimation of absolute dose rate values. It was found necessary to consider medium boundaries when comparing results for the radial dose function of 169 Yb and 192 Ir sources to avoid discrepancies due to the backscattering contribution in the phantom medium. Values of g(r) for all source types studied are presented. Uncertainties lie under 1% within one standard deviation. (author)

  13. The surgical viability and radiological monitoring of brain implants of bioactive micro-seeds in an animal model

    Directory of Open Access Journals (Sweden)

    Giane X. O. Silva

    2005-10-01

    Full Text Available The interstitial implant is a therapeutic modality in brachytherapy of the head and neck. Presently, the seeds implanted in tumors in the central nervous system are metallic I-125. After the full emission of the radionuclide, the seed remains inert in the implanted area. Bioactive ceramic seeds have been prepared for this research group incorporating Sm-152 to be active in Sm-153. The main goal of the present study is the development of a the surgical technique for implanting the biodegradable radioactive micro-seeds in the brains of rabbits, as well as the observation of the clinical reactions of the animal after implantation of two sets of three seeds. The surgical procedure consisted of performing two separate perforations 10 mm from each other in the skull, permitting the implantation of two groups of three seeds, totaling six seeds. The results of the pilot study showed the effectiveness of the surgical procedure and of the biocompatibility of the seeds and the lack of presence of adverse reactions, functional sequels, or inflammation in a follow up 50 days post-surgery. Such seeds of reduced volume, 0.2 x 1.6 mm, could be monitored by computerized tomography 30 days after implanting.Os implantes intersticiais podem ser utilizados em braquiterapia de cabeça e pescoço. Atualmente as sementes implantadas no CNS são de I-125 metálicas. Após o decaimento do radioisótopo, a semente fica inerte na região implantada. Sementes cerâmicas bioativas tem sido preparadas pelo grupo de pesquisa incorporando Sm-152. O presente estudo tem o objetivo de viabilizar a técnica cirúrgica de implantes de microsementes biodegradáveis não radioativas no cérebro de coelhos, bem como verificar as reações clínicas e funcionais do animal ao corpo estranho implantado. O procedimento cirúrgico compreendeu em proceder duas perfurações separadas em 10mm na calota craniana onde foi possível a implantação de dois conjuntos de três sementes

  14. The preparation of 125I-β-CIT and its biological distribution in animal

    International Nuclear Information System (INIS)

    Sun Wenshan; Liu Zhenguo; Shen Minghua; Qian Juan; Li Peiyong; Zhu Chengmo; Chen Shengdi

    2000-01-01

    Objective: To prepare and label the 125 I-β-CIT and study its biological distribution in animal. Methods: 125 I-β-CIT was prepared by the peracetic acid method and the chloramine-T method, and dopamine transporter (DAT) binding properties of 125 I-β-CIT were examined by in vivo biodistribution and inhibition studies in mice and whole body autoradiography in rats. Results: The radiolabelling yields of the peracetic acid and the chloramine-T methods were (53.4 +- 7.9)% and (88.4 +- 3.49)%, respectively. Following intravenous injection in mice, 125 I-β-CIT showed high accumulation in striatum, time to peak level uptake was 2 h after injection. GBR12909 significantly inhibited 125 I-β-CIT binding in striatum, while clomipramine significantly inhibited 125 I-β-CIT binding in hippocampus and cerebral cortex. The rat whole body autoradiography showed that the clearance of the tracer occurred through the hepatobiliary route. Conclusions: The results indicate β-CIT is an agent suitable for DAT imaging and can be used for the study of Parkinson's disease

  15. Chloroquine allows the secretion of internalized 125I-epidermal growth factor from fibroblasts

    International Nuclear Information System (INIS)

    Wakshull, E.; Cooper, J.L.; Wharton, W.

    1985-01-01

    Incubation of cells with labelled hormone in the presence of the lysosomotropic agent chloroquine produces an enhanced intracellular accumulation of hormone and receptor. Using a pulse-chase paradigm in which cell surface receptors were labelled with 125 I-EGF at 4 degrees C, it was found that when 100 microM chloroquine was present in the 37 degrees C chase medium intact hormone was accumulated in the medium. Without chloroquine, low molecular weight (mw) degradation products were found in the medium. The processes of receptor-mediated endocytosis and subcellular distribution of 125 I-EGF-receptor complexes were unchanged by chloroquine. The source of the intact hormone accumulating in the medium was therefore an intracellular compartment(s). The 125 I-EGF released from the cells could rebind to surface receptors and be re-internalized; rebinding was inhibited by unlabelled EGF or Concanavalin A in the incubation medium. The concentration of unlabelled EGF required to inhibit rebinding was more than three orders of magnitude greater than the amount of 125 I-EGF whose rebinding was inhibited. Thus, the 125 I-EGF released from intracellular sites was rebound preferentially over exogenous EGF. The possible pathways for secretion of intact 125 I-EGF and mechanisms of its preferential rebinding are discussed

  16. Dosimetry verification of radioactive seed implantation for malignant tumors assisted by 3D printing individual templates and CT guidance

    International Nuclear Information System (INIS)

    Ji, Zhe; Jiang, Yuliang; Guo, Fuxin; Sun, Haitao; Fan, Jinghong; Zhang, Lujing; Wang, Junjie

    2017-01-01

    Objective: We compared the dose distributions of postoperative plans with preoperative plans for 3D printing template-assisted radioactive seed implantations. Methods: A total of 14 patients with malignant tumors enrolled in the study. The dose parameters included D90, minimum peripheral dose, V100, V150, and V200. The statistical method was the paired t-test. Results: There was no significant difference in P values between the two groups for all parameters except for V100. Conclusions: The 3D printing guide template can provide good accuracy for radioactive seed implantation. - Highlights: • It is the first study we as for as we know to compare the preoperative and postoperative dosimetry results of 3D printing templates-assisted radioactive seeds implantation for malignant tumor. • 3D printing guide template can provide good accuracy for radioactive seeds implantation. • The actual dose distributions in postoperative validations were closed to the expectations of preoperative plans. • 3D printing template providing us an effective tool for the standardization and normalization of seed implantation, and having a good application prospect and worthy of further development and popularization.

  17. Aspects of an automatic system of implants of radioactive seeds and anatomic object simulator for tests in prostate brachytherapy

    Energy Technology Data Exchange (ETDEWEB)

    Silva, Leonardo S.M.; Braga, Viviane V.B.; Campos, Tarcísio P. R. de, E-mail: leonardosantiago.lsms@gmail.com, E-mail: vitoriabraga06@gmail.com, E-mail: tprcampos@yahoo.com.br [Universidade Federal de Minas Gerais (PCTN/UFMG), Belo Horizonte (Brazil). Pós-Graduação em Ciências e Técnicas Nucleares. Departamento de Engenharia Nuclear

    2017-07-01

    This work presents the state of the art of the research and development of an automatic radioactive seed implantation system (PSIS). PSIS may assist in the procedure of testing permanent implants in the prostate. These tests will be important in measurements of absorbed doses in the pelvic structures, involving the organs and tissues at risk to improve planning, seed positioning and dosimetry. The automated Prostate Seed Implant System (PSIS) has been designed to meet operational needs, which offers the freedom of positioning of the brachytherapy needle within the treatment area and ensures repeatability and fidelity to the planned treatment. Both the ultrasound probe and the seed implant needle are driven by step motors, Atmega microcontroller, bearings, aluminum shafts and a GUI (Graphical User Interface). Movement of both the probe and the needle holder was performed by fixed spindle on a threaded rod rushing to the step motors by a coupling. The step motors used to move the system consist of step motors used in CNC (Computer Numeric Control) machine. The choice of these engines occurred due to the precision in the movements that can be obtained with these types of motors. The ultrasound probe serves to help, through the images acquired during the longitudinal movement, to monitor the application of the seeds. The parts that make up the system infrastructure were made of aluminum and translucent acrylic and cylindrical aluminum bars of different diameters. All these pieces were fixed and adjusted trough screws, washers, nuts and adhesive to metal, composing the final prototype of the PSIS. The project was developed and the PSIS prototype was assembled. The prototype presented acceptable operating characteristics for prostate implants. The advantage of this system is the automation of the application that provides an accurate positioning and movement of both probe and seed application. In addition to this study, seeds implantation tests will be performed, and

  18. Aspects of an automatic system of implants of radioactive seeds and anatomic object simulator for tests in prostate brachytherapy

    International Nuclear Information System (INIS)

    Silva, Leonardo S.M.; Braga, Viviane V.B.; Campos, Tarcísio P. R. de

    2017-01-01

    This work presents the state of the art of the research and development of an automatic radioactive seed implantation system (PSIS). PSIS may assist in the procedure of testing permanent implants in the prostate. These tests will be important in measurements of absorbed doses in the pelvic structures, involving the organs and tissues at risk to improve planning, seed positioning and dosimetry. The automated Prostate Seed Implant System (PSIS) has been designed to meet operational needs, which offers the freedom of positioning of the brachytherapy needle within the treatment area and ensures repeatability and fidelity to the planned treatment. Both the ultrasound probe and the seed implant needle are driven by step motors, Atmega microcontroller, bearings, aluminum shafts and a GUI (Graphical User Interface). Movement of both the probe and the needle holder was performed by fixed spindle on a threaded rod rushing to the step motors by a coupling. The step motors used to move the system consist of step motors used in CNC (Computer Numeric Control) machine. The choice of these engines occurred due to the precision in the movements that can be obtained with these types of motors. The ultrasound probe serves to help, through the images acquired during the longitudinal movement, to monitor the application of the seeds. The parts that make up the system infrastructure were made of aluminum and translucent acrylic and cylindrical aluminum bars of different diameters. All these pieces were fixed and adjusted trough screws, washers, nuts and adhesive to metal, composing the final prototype of the PSIS. The project was developed and the PSIS prototype was assembled. The prototype presented acceptable operating characteristics for prostate implants. The advantage of this system is the automation of the application that provides an accurate positioning and movement of both probe and seed application. In addition to this study, seeds implantation tests will be performed, and

  19. Cell Seeding Densities in Autologous Chondrocyte Implantation Techniques for Cartilage Repair.

    Science.gov (United States)

    Foldager, Casper Bindzus; Gomoll, Andreas H; Lind, Martin; Spector, Myron

    2012-04-01

    Cartilage repair techniques have been among the most intensively investigated treatments in orthopedics for the past decade, and several different treatment modalities are currently available. Despite the extensive research effort within this field, the generation of hyaline cartilage remains a considerable challenge. There are many parameters attendant to each of the cartilage repair techniques that can affect the amount and types of reparative tissue generated in the cartilage defect, and some of the most fundamental of these parameters have yet to be fully investigated. For procedures in which in vitro-cultured autologous chondrocytes are implanted under a periosteal or synthetic membrane cover, or seeded onto a porous membrane or scaffold, little is known about how the number of cells affects the clinical outcome. Few published clinical studies address the cell seeding density that was employed. The principal objective of this review is to provide an overview of the cell seeding densities used in cell-based treatments currently available in the clinic for cartilage repair. Select preclinical studies that have informed the use of specific cell seeding densities in the clinic are also discussed.

  20. Systemic administration of kainic acid induces selective time dependent decrease in [125I]insulin-like growth factor I, [125I]insulin-like growth factor II and [125I]insulin receptor binding sites in adult rat hippocampal formation

    International Nuclear Information System (INIS)

    Quirion, R.; Chabot, J.-G.; Dore, S.; Seto, D.; Kar, S.

    1997-01-01

    Administration of kainic acid evokes acute seizure in hippocampal pathways that results in a complex sequence of functional and structural alterations resembling human temporal lobe epilepsy. The structural alterations induced by kainic acid include selective loss of neurones in CA1-CA3 subfields and the hilar region of the dentate gyrus followed by sprouting and permanent reorganization of the synaptic connections of the mossy fibre pathways. Although the neuronal degeneration and process of reactive synaptogenesis have been extensively studied, at present little is known about means to prevent pathological conditions leading to kainate-induced cell death. In the present study, to address the role of insulin-like growth factors I and II, and insulin in neuronal survival as well as synaptic reorganization following kainate-induced seizure, the time course alterations of the corresponding receptors were evaluated. Additionally, using histological preparations, the temporal profile of neuronal degeneration and hypertrophy of resident astroglial cells were also studied. [ 125 I]Insulin-like growth factor I binding was found to be decreased transiently in almost all regions of the hippocampal formation at 12 h following treatment with kainic acid. The dentate hilar region however, exhibited protracted decreases in [ 125 I]insulin-like growth factor I receptor sites throughout (i.e. 30 days) the study. [ 125 I]Insulin-like growth factor II receptor binding sites in the hippocampal formation were found to be differentially altered following systemic administration of kainic acid. A significant decrease in [ 125 I]insulin-like growth factor II receptor sites was observed in CA1 subfield and the pyramidal cell layer of the Ammon's horn at all time points studied whereas the hilar region and the stratum radiatum did not exhibit alteration at any time. A kainate-induced decrease in [ 125 I]insulin receptor binding was noted at all time points in the molecular layer of the

  1. Ultrasonically guided 125iodine seed implantation with external radiation in management of localized prostatic carcinoma

    DEFF Research Database (Denmark)

    Iversen, P; Bak, M; Juul, N

    1989-01-01

    Thirty-three patients with localized prostatic carcinoma (16 poorly differentiated) were treated with transperineal 125Iodine seed implantation (160 Gy) guided by transrectal ultrasonography and subsequent external beam irradiation (47.4 Gy). The observation time was six to sixty-eight months...... with a median follow-up of thirty-five months. Median change in prostatic volume was a reduction of 35 percent. Re-biopsy or transurethral resection of the prostate was performed in 25 patients after one to two years, revealing still malignant histology in 12 (48%). Development of distant metastases occurred...

  2. Patterns of failure after iodine-125 seed implantation for prostate cancer

    International Nuclear Information System (INIS)

    Lamb, David S.; Greig, Lynne; Russell, Grant L.; Nacey, John N.; Broome, Kim; Studd, Rod; Delahunt, Brett; Iupati, Douglas; Jain, Mohua; Rooney, Colin; Murray, Judy; Lamb, Peter J.; Bethwaite, Peter B.

    2014-01-01

    Purpose: To determine the site of relapse when biochemical failure (BF) occurs after iodine-125 seed implantation for prostate cancer. Materials and methods: From 2001–2009, 500 men underwent implantation in Wellington, New Zealand. Men who sustained BF were placed on relapse guidelines that delayed restaging and intervention until the prostate-specific antigen (PSA) was ⩾20 ng/mL. Results: Most implants (86%) had a prostate D90 of ⩾90%, and multivariate analysis showed that this parameter was not a variable that affected the risk of BF. Of 21 BFs that occurred, the site of failure was discovered to be local in one case and distant in nine cases. Restaging failed to identify the site of relapse in two cases. In nine cases the trigger for restaging had not been reached. Conclusions: If post-implant dosimetry is generally within the optimal range, distant rather than local failure appears to be the main cause of BF. Hormone treatment is therefore the most commonly indicated secondary treatment intervention (STI). Delaying the start of STI prevents the unnecessary treatment of men who undergo PSA ‘bounce’ and have PSA dynamics initially mimicking those of BF

  3. WE-A-17A-11: Implanted Brachytherapy Seed Movement Due to Transrectal Ultrasound Probe-Induced Prostate Deformation

    Energy Technology Data Exchange (ETDEWEB)

    Liu, D; Usmani, N; Sloboda, R [Cross Cancer Institute, Edmonton, Alberta (Canada); University of Alberta, Edmonton, Alberta (Canada); Meyer, T; Husain, S; Angyalfi, S [Tom Baker Cancer Centre, Calgary, Alberta (Canada); University of Calgary, Calgary, Alberta (Canada); Kay, I [Canterbury District Health Board, Christchurch (New Zealand)

    2014-06-15

    Purpose: To characterize the movement of implanted brachytherapy seeds due to transrectal ultrasound probe-induced prostate deformation and to estimate the effects on prostate dosimetry. Methods: Implanted probe-in and probe-removed seed distributions were reconstructed for 10 patients using C-arm fluoroscopy imaging. The prostate was delineated on ultrasound and registered to the fluoroscopy seeds using a visible subset of seeds and residual needle tracks. A linear tensor and shearing model correlated the seed movement with position. The seed movement model was used to infer the underlying prostate deformation and to simulate the prostate contour without probe compression. Changes in prostate and surrogate urethra dosimetry were calculated. Results: Seed movement patterns reflecting elastic decompression, lateral shearing, and rectal bending were observed. Elastic decompression was characterized by anterior-posterior expansion and superior-inferior and lateral contractions. For lateral shearing, anterior movement up to 6 mm was observed for extraprostatic seeds in the lateral peripheral region. The average intra-prostatic seed movement was 1.3 mm, and the residual after linear modeling was 0.6 mm. Prostate D90 increased by 4 Gy on average (8 Gy max) and was correlated with elastic decompression. For selected patients, lateral shearing resulted in differential change in D90 of 7 Gy between anterior and posterior quadrants, and increase in whole prostate D90 of 4 Gy. Urethra D10 increased by 4 Gy. Conclusion: Seed movement upon probe removal was characterized. The proposed model captured the linear correlation between seed movement and position. Whole prostate dose coverage increased slightly, due to the small but systematic seed movement associated with elastic decompression. Lateral shearing movement increased dose coverage in the anterior-lateral region, at the expense of the posterior-lateral region. The effect on whole prostate D90 was smaller due to the subset

  4. DNA strand breakage by 125I-decay in oligoDNA

    International Nuclear Information System (INIS)

    Lobachevsky, P.; Martin, R.F.

    1996-01-01

    Full text: A double-stranded oligodeoxynucleotide containing 125 I-dC in a defined location, with 5'- or 3'- 32 P-end-labelling of either strand, was used to investigate DNA strand breakage resulting from 125 I decay. Samples of the 32 P-end-labelled and 125 I-dC containing oligoDNA were incubated in 20 mM phosphate buffer (PB), or PB + 2 M dimethylsulphoxide (DMSO) at 4 deg during 18-20 days. The 32 P-end-labelled DNA fragments produced by 125 I decays were separated on denaturing polyacrylamide gels, and the 3P activity in each fragment was determined by scintillation counting after elution from the gel. The fragment size distribution was then converted to a distribution of single stranded break probabilities at each nucleotide position. The results indicate that each 125 I decay event produces at least one break in the 125 I-dC containing strand, and causes breakage of the opposite strand in 75-80% of events. Thus, the double stranded break is produced by 125 I decay with probability ∼0.8. Most of single stranded breaks (around 90%) occurred within 5-6 nucleotides of the 125 I-dC, however DNA breaks were detected up to 18-20 nucleotides from the decay site. The average numbers of single stranded breaks per decay are 3.7 (PB) and 3.3 (PB+DMSO) in 125 I-dC containing strand, and 1.5 (PB) and 1.3 (PB+DMSO) in the opposite strand. Deconvolution of strand break probabilities as a function of separation from the 125 I, in terms of both distance (to target deoxyribosyl carbon atoms, in B-DNA) and nucleotide number, show that the latter is an important parameter for the shorter-range damage. This could indicate a role for attenuation/dissipation of damage through the stacked bases. In summary, the results represent a much more extensive set of data than available from earlier experiments on DNA breakage from l25 I-decay, and may provide new mechanistic insights

  5. Study on preparation and brain distribution of 125I-β-CIT

    International Nuclear Information System (INIS)

    Liu Xingdang; Lin Xiangtong

    2002-01-01

    Objective: To develop a relatively simpler and faster method for the routine preparation of 125 I-β-CIT and animal brain distribution of 125 I-β-CIT. Methods: Peracetic acid or Iodogen as an oxidant was used to prepare 125 I-β-CIT and comparison was made between them. The HPLC purification technique was used to identify the labeled tracer. Stability and safety of the radioiodinated β-CIT were also studied. Groups of mice (n=5) were injected i.v. into the tail vein with 125 I-β-CIT . Animals were killed at 5, 15, 30 and 45 minutes, and 1, 2, 4, 6, 8 and 24 hours. Autoradiography was performed on brains of mice at 4 hours after injection. Results: Two kinds of labeling methods using Iodogen or peracetic acid produced 125 I-β-CIT of radiochemical yields 91.10% ± 8.09%, 54.70 ± 9.81% respectively, with high radiochemical purity (RCP) 99.33% ± 0.15%, 18-25 degree C and pH 1 or 2 is the best for Iodogen preparation. The labeled product was stable for at least 23 days when kept in room temperature, and stable for at least 10 weeks when kept in -4 degree C refrigerator. The peak time of uptake of 125 I-β-CIT in striatum was at four hours after injection and the highest value was 22.93% ± 3.11% ID/g. It's highest uptake rate is 20.09 ± 2.11. Conclusions: The Iodogen preparation method is simpler and has a higher labeling yield than peracetic acid labeling method and the labeling yield is higher than which ever reported abroad. The labeled radiopharmaceutical is stable. 125 I-β-CIT showed the highest accumulation in striatum with high densities of dopamine transporters in brain

  6. Autoradiographic localization of putative nicotinic receptors in the rat brain using 125I-neuronal bungarotoxin

    International Nuclear Information System (INIS)

    Schulz, D.W.; Loring, R.H.; Aizenman, E.; Zigmond, R.E.

    1991-01-01

    Neuronal bungarotoxin (NBT), a snake venom neurotoxin, selectively blocks nicotinic receptors in many peripheral and central neuronal preparations. alpha-Bungarotoxin (alpha BT), on the other hand, a second toxin isolated from the venom of the same snake, is an ineffective nicotinic antagonist in most vertebrate neuronal preparations studied thus far. To examine central nicotinic receptors recognized by NBT, we have characterized the binding of 125I-labeled NBT (125I-NBT) to rat brain membranes and have mapped the distribution of 125I-NBT binding in brain sections using quantitative light microscopic autoradiography. The binding of 125I-NBT was found to be saturable, of high affinity, and heterogeneously distributed in the brain. Pharmacological studies suggested that more than one population of sites is labeled by 125I-NBT. For example, one component of 125I-NBT binding was also recognized by alpha BT, while a second component, not recognized by alpha BT, was recognized by the nicotinic agonist nicotine. The highest densities of these alpha BT-insensitive, nicotine-sensitive sites were found in the fasciculus retroflexus, the lateral geniculate nucleus, the medial terminal nucleus of the accessory optic tract, and the olivary pretectal nucleus. alpha BT-sensitive NBT binding sites were found in highest density in the lateral geniculate nucleus, the subthalamic nucleus, the dorsal tegmental nucleus, and the medial mammillary nucleus (lateral part). The number of brain regions with a high density of 125I-NBT binding sites, blocked either by alpha BT or by nicotine, is low when compared with results obtained using other approaches to studying the central distribution of nicotinic receptors, such as labeling with 3H-nicotine or labeling with cDNA probes to mRNAs coding for putative receptor subunits

  7. Bypassing the learning curve in permanent seed implants using state-of-the-art technology

    International Nuclear Information System (INIS)

    Beaulieu, Luc; Evans, Dee-Ann Radford; Aubin, Sylviane; Angyalfi, Steven; Husain, Siraj; Kay, Ian; Martin, Andre-Guy; Varfalvy, Nicolas; Vigneault, Eric; Dunscombe, Peter

    2007-01-01

    Purpose: The aim of this study was to demonstrate, based on clinical postplan dose distributions, that technology can be used efficiently to eliminate the learning curve associated with permanent seed implant planning and delivery. Methods and Materials: Dose distributions evaluated 30 days after the implant of the initial 22 consecutive patients treated with permanent seed implants at two institutions were studied. Institution 1 (I1) consisted of a new team, whereas institution 2 (I2) had performed more than 740 preplanned implantations over a 9-year period before the study. Both teams had adopted similar integrated systems based on three-dimensional (3D) transrectal ultrasonography, intraoperative dosimetry, and an automated seed delivery and needle retraction system (FIRST, Nucletron). Procedure time and dose volume histogram parameters such as D90, V100, V150, V200, and others were collected in the operating room and at 30 days postplan. Results: The average target coverage from the intraoperative plan (V100) was 99.4% for I1 and 99.9% for I2. D90, V150, and V200 were 191.4 Gy (196.3 Gy), 75.3% (73.0%), and 37.5% (34.1%) for I1 (I2) respectively. None of these parameters shows a significant difference between institutions. The postplan D90 was 151.2 Gy for I1 and 167.3 Gy for I2, well above the 140 Gy from the Stock et al. analysis, taking into account differences at planning, results in a p value of 0.0676. The procedure time required on average 174.4 min for I1 and 89 min for I2. The time was found to decrease with the increasing number of patients. Conclusion: State-of-the-art technology enables a new brachytherapy team to obtain excellent postplan dose distributions, similar to those achieved by an experienced team with proven long-term clinical results. The cost for bypassing the usual dosimetry learning curve is time, with increasing team experience resulting in shorter treatment times

  8. Evaluation of dose-volume histograms after prostate seed implantation. 4-year experience

    International Nuclear Information System (INIS)

    Hoinkis, C.; Lehmann, D.; Winkler, C.; Herrmann, T.; Hakenberg, O.W.; Wirth, M.P.

    2004-01-01

    Background and purpose: permanent interstitial brachytherapy by seed implantation is a treatment alternative for low-volume low-risk prostate cancer and a complex interdisciplinary treatment with a learning curve. Dose-volume histograms are used to assess postimplant quality. The authors evaluated their learning curve based on dose-volume histograms and analyzed factors influencing implantation quality. Patients and methods: since 1999, 38 patients with a minimum follow-up of 6 months were treated at the authors' institution with seed implantation using palladium-103 or iodine-125, initially using the preplan method and later real-time planning. Postimplant CT was performed after 4 weeks. The dose-volume indices D90, V100, V150, the D max of pre- and postplans, and the size and position of the volume receiving the prescribed dose (high-dose volume) of the postplans were evaluated. In six patients, postplan imaging both by CT and MRI was used and prostate volumes were compared with preimplant transrectal ultrasound volumes. The first five patients were treated under external supervision. Results: patients were divided into three consecutive groups for analysis of the learning curve (group 1: n = 5 patients treated under external supervision; group 2: n = 13 patients; group 3: n = 20 patients). D90 post for the three groups were 79.3%, 74.2%, and 99.9%, the V100 post were 78.6%, 73.5%, and 88.2%, respectively. The relationship between high-dose volume and prostate volume showed a similar increase as the D90, while the relationship between high-dose volume lying outside the prostate and prostate volume remained constant. The ratio between prostate volumes from transrectal ultrasound and CT imaging decreased with increasing D90 post , while the preplanning D90 and V100 remained constant. The different isotopes used, the method of planning, and the implanted activity per prostate volume did not influence results. Conclusion: a learning curve characterized by an increase

  9. Targeted radiotherapy of multicell neuroblastoma spheroids with high specific activity [125I]meta-iodobenzylguanidine

    International Nuclear Information System (INIS)

    Roa, Wilson H.Y.; Miller, Gerald G.; McEwan, Alexander J.B.; McQuarrie, Steve A.; Tse, Jeanie; Wu, Jonn; Wiebe, Leonard I.

    1998-01-01

    Purpose: Iodine-125 induces cell death by a mechanism similar to that of high linear energy transfer (high-LET) radiation. This study investigates the cytotoxicity of high-specific-activity [ 125 I]meta-iodobenzylguanidine ( 125 I-mIBG) in human SK-N-MC neuroblastoma cells grown as three-dimensional multicellular spheroids. Materials and Methods: Spheroids were incubated with high-specific-activity 125 I-mIBG (6 mCi/μg, 1000 times that of the conventional specific activity used for autoradiography). Cytotoxicity was assessed by fluorescence viability markers and confocal microscopy for intact spheroids, fluorescence-activated cell sorting and clonogenic assay, and clonogenic assays for dispersed whole spheroids. Distribution of radioactive mIBG was determined by quantitative light-microscope autoradiography of spheroid cryostat sections. Dose estimation was based on temporal knowledge of the retained radioactivity inside spheroids, and of the radiolabel's emission characteristics. Findings were compared with those of spheroids treated under the same conditions with 131 I-mIBG, cold mIBG, and free iodine-125. Results: 125 I-mIBG exerted significant cell killing. Complete spheroids were eradicated when they were treated with 500 μCi of 125 I-mIBG, while those treated with 500 μCi or 1000 μCi of 131 I-mIBG were not. The observed difference in cytotoxicity between treatments with 125 I- and 131 I-mIBG could not be accounted for by the absorbed dose of spheroid alone. The peripheral, proliferating cell layer of the spheroids remained viable at the moderate radioactivity of 100 μCi for both isotopes. Cytotoxicity induced by 125 I-mIBG was quantitatively comparable by the peripheral rim thickness to that of 131 I-mIBG at the dose of 100 μCi. The peripheral rim thickness decreased most significantly in the first 17 hours after initial treatment. There was no statistical decrease in the rim thickness identified afterwards for the second, third, and fourth days of

  10. Separation of 134Cs and 137Cs from 125I solution for medical applications

    International Nuclear Information System (INIS)

    Ram, Ramu; Dash, Ashutosh; Banerjee, Dayamoy

    2015-01-01

    While neutron irradiation of natural Xe gas followed by wet chemical dissolution of activation products constitutes a successful paradigm for the small scale production 125 I, the concomitant production of 134 Cs and 137 Cs emerged as the primary impediment which necessitates purification of 125 I solution. This paper describes an ion-exchange chromatographic technique using Resorcinol Formaldehyde (RF) resin to purify 125 I solution from 134 Cs and 137 Cs impurities. A thorough investigation of the adsorption parameters of RF resin was carried out to arrive at the experimental conditions resulting optimum retention of 134 Cs and 137 Cs impurities. Based on the experimental findings, an optimized separation procedure was developed in which the neutron irradiated dissolved products at pH ∝ 13 was passed through a chromatography column containing RF resin where in 134 Cs and 137 Cs impurities gets adsorbed leaving behind 125 I to appear in the effluent. The overall recovery of 125 I was >90% with acceptable purity amenable for clinical applications.

  11. Radioimmunoassay for etorphine in horses with a 125I analog of etorphine

    International Nuclear Information System (INIS)

    Tai, C.L.; Wang, C.; Weckman, T.J.; Popot, M.A.; Woods, W.E.; Yang, J.M.; Blake, J.; Tai, H.H.; Tobin, T.

    1988-01-01

    To improve the sensitivity and specificity of screening for etorphine in horses, an 125 I-labeled etorphine analog was synthesized and an antibody to etorphine was raised in rabbits. A radioimmunoassay (RIA) for etorphine was developed, using these reagents. Bound and free 125 I-labeled etorphine was separated by a double-antibody method that reduced interference from materials associated with equine urine. The 125 I-labeled etorphine binding was rarely greater than 250 pg of background etorphine equivalents/ml in raw urine and was 100 pg/ml in hydrolyzed urine. The 125 I-RIA was capable of detecting etorphine equivalents in urine above these background values. Etorphine equivalents were detected in equine urine samples for about 7 days after 4 mares were dosed with 0.22 microgram of etorphine/kg of body weight, IV. The stability of etorphine in urine from these mares was evaluated. Urine from these dosed mares was held in constant -20 C storage, and aliquots were repeatedly frozen and thawed. When analyzed for etorphine equivalents using an 125 I-RIA, etorphine and its metabolites in urine samples were stable for less than or equal to 38 days if continuously frozen and also were resistant to repeated freezing and thawing

  12. Studies of the distribution of intrathecally injected 125I-tetanus antitoxin-F(ab')2

    International Nuclear Information System (INIS)

    Hanauske, A.R.

    1981-01-01

    Overall F(ab') 2 and antitetanus-f(ab') 2 - fragments were labelled with 125 I and injected i.th. into normal juvenile cats and adult rats. One group of rats was normal; in the other, unilateral local tetanus had been induced by injection of tetanus toxin into a M. gastrocnemius. The animals were sacrificed 24 h after the i.th. injection, and tissue samples were taken for histoautoradiography. 125 I-antitetanus-F(ab') 2 permeated into the extracellular space of the spinal cord, roots, and ganglia but not into the neuronal intracellular space. 125 I-overall-F(ab') showed identical permeation behaviour. 125 I-antitetanus-F(ab') 2 reacted with tetanus toxin issuing from the motoneurons after i.th. injection, forming an immunocomplex around the motorneurons. The immunocomplex was not formed around pseudo-unipolar ganglian cells in the spinal ganglia even though some of the ganglian cells contained tetanus toxin, and 125 I-antitetanus-F(ab') 2 was present in the extracellular space. As an explanation, it was suggested that tetanus toxin does not permeate into the extracellular space through the membrane of the pseudo-unipolar ganglian cells so that immune reactions will not occur. These findings help to explain the widely divergent results of tetanus therapy by means of i.th. injection of tetanus antitoxin. Recommendations for future therapy measures are derived from the findings. (orig./MG) [de

  13. Synthesis and biologic studies of iodinated (125I/127I) ethidium

    International Nuclear Information System (INIS)

    Ho Nanhui; Tumeh, Paul C.; Kassis, Amin I.

    2001-01-01

    An iodinated ( 125 I/ 127 I) ethidium derivative (3,8-diamino-5-[6'-(p-iodobenzoylamino)-4'-azahexyl]-6 -phenylphenanthridinium chloride hydrochloride) was synthesized and characterized. The labeling yield of the 125 I-labeled derivative was 75% for carrier-free 125 I, with a radiochemical purity of 95%. The incubation of iodoethidium with calf thymus DNA resulted in a substantial enhancement of fluorescence yield, indicating the intercalation of this compound into DNA. In the presence of iodoethidium, the nuclei of methanol-treated mammalian cells fluoresced, while those of viable cells did not (since the plasma membrane is impermeable to iodoethidium). When viable cells were incubated with the reduced form of the derivative, 125 I/ 127 I-dihydroethidium traversed the plasma membrane, was oxidized in the cytoplasm, and intercalated into nuclear DNA. Finally, we tested the hypothesis that larger malignant solid tumors, containing a relatively greater percentage of degenerating permeable cells, can be targeted with 125 I-ethidium. In-vivo studies demonstrated a small but positive correlation (R = 0.72) between tumor volume and the uptake of the derivative. Because of the ubiquitous presence of abnormal permeable cells and necrosis in tumors, our results support the belief that radiolabeled DNA-intercalating or DNA-binding molecules may be of diagnostic and therapeutic value for a variety of solid tumors in humans

  14. Synthesis and biologic studies of iodinated ({sup 125}I/{sup 127}I) ethidium

    Energy Technology Data Exchange (ETDEWEB)

    Ho Nanhui; Tumeh, Paul C.; Kassis, Amin I. E-mail: amin_kassis@hms.harvard.edu

    2001-11-01

    An iodinated ({sup 125}I/{sup 127}I) ethidium derivative (3,8-diamino-5-[6'-(p-iodobenzoylamino)-4'-azahexyl]-6 -phenylphenanthridinium chloride hydrochloride) was synthesized and characterized. The labeling yield of the {sup 125}I-labeled derivative was 75% for carrier-free {sup 125}I, with a radiochemical purity of 95%. The incubation of iodoethidium with calf thymus DNA resulted in a substantial enhancement of fluorescence yield, indicating the intercalation of this compound into DNA. In the presence of iodoethidium, the nuclei of methanol-treated mammalian cells fluoresced, while those of viable cells did not (since the plasma membrane is impermeable to iodoethidium). When viable cells were incubated with the reduced form of the derivative, {sup 125}I/{sup 127}I-dihydroethidium traversed the plasma membrane, was oxidized in the cytoplasm, and intercalated into nuclear DNA. Finally, we tested the hypothesis that larger malignant solid tumors, containing a relatively greater percentage of degenerating permeable cells, can be targeted with {sup 125}I-ethidium. In-vivo studies demonstrated a small but positive correlation (R = 0.72) between tumor volume and the uptake of the derivative. Because of the ubiquitous presence of abnormal permeable cells and necrosis in tumors, our results support the belief that radiolabeled DNA-intercalating or DNA-binding molecules may be of diagnostic and therapeutic value for a variety of solid tumors in humans.

  15. [125I] radioiodinated metaraminol: A new platelet-specific labeling agent

    International Nuclear Information System (INIS)

    Ohmomo, Y.; Yokoyama, A.; Kawai, K.; Arano, Y.; Horiuchi, K.; Saji, H.; Torizuka, K.

    1985-01-01

    In our search for a platelet-specific labeling agent, metaraminol (MA), a low-toxic pharmaceutical for the treatment of hypotension and cardiogenic shock, attracted our attention. Its active incorporation and accumulation by platelets have been recognized. At first, the preparation of 125 I radioiodinated metaraminol ( 125 I-MA) was carried out using the chloramine-T method. Then, upon the harvest of platelets as platelet-rich plasma (PRP), their labeling with this new radiopharmaceutical was easily performed by incubation for 10 min at 37 0 C. The cell-labeling efficiency was dependent on cell density, reaching 63.0%+-3.1% at 2.4x10 9 cells/ml. The specific incorporation of 125 I-MA by an active transport system similar to that of 5-hydroxytryptamine (5-HT) as well as by passive diffusion was demonstrated. In vitro studies, the unaltered state of 125 I-MA-labeled platelets with their cellular functions fully retained was estimated. In vivo studies carried out in rabbits with induced thrombi in the femoral artery showed a rather rapid disappearance of the radioactivity from circulating blood, reaching a high thrombus-to-blood activity ratio of 19.8+-4.3 within 30 min of the administration of 125 I-MA-labeled autologous platelets. Thus, with the potential availability of 123 I, 123 I-MA-labeled platelets appear to be a promising agent for thrombus imaging using single-emission computed tomography (CT) studies. (orig.)

  16. 125I-iomazenil-benzodiazepine receptor binding during psychological stress in rats

    International Nuclear Information System (INIS)

    Fukumitsu, Nobuyoshi; Tsuchida, Daisuke; Ogi, Shigeyuki; Uchiyama, Mayuki; Mori, Yutaka

    2002-01-01

    We investigated the changes in 125 I-iomazenil ( 125 I-IMZ) benzodiazepine receptor (BZR) binding with psychological stress in a rat model. Six male Wistar rats were placed under psychological stress for 1 hour by using a communication box. No physical stress was not received. 1.85 MBq of 125 I-IMZ was injected into the lateral tail vein and the rat was killed 3 hours later. Twenty-micormeter-thick sections of the brain were collected and % injected dose per body weight (% ID/BW) of eleven regions (frontal, parietal, temporal, occipital cortices, caudate putamen, accumubens nuclei, globus pallidus, amygdala, thalamus, hippocampus and hypothalamus) were calculated by autoradiography. The %ID/BW of rats which were placed under psychological stress was compared with that of 6 control rats. The %ID/BW of rats which were placed under psychological stress diffusely tended to show a reduction in 125 I-IMZ-BZR binding. A significant decrease in BZR binding was observed in the hippocampus of the rats which were placed under psychological stress. 125 I-IMZ-BZR binding tended to decrease throughout the brain. (author)

  17. Radioimmunoassay of salivary cyclosporine with use of 125I-labeled cyclosporine

    International Nuclear Information System (INIS)

    Coates, J.E.; Lam, S.F.; McGaw, W.T.

    1988-01-01

    We prepared 125 I-labeled cyclosporine ( 125 I-CS) by modifying the procedure of Mahoney and Orf and characterized it with regards to maximal immunoreactivity (greater than 90%), trichloroacetic acid precipitability (greater than 90%), and stability (90% immunoreactive after five half-lives of 125 I). For a particular preparation of 125 I-CS, we estimated its immunoreaction concentration (50 pmol/L) and the equilibrium constant for its reaction with Sandoz polyclonal antiserum (K = 3.9 X 10(9) L/mol). By substituting 125 I-CS as tracer in the Sandoz radioimmunoassay and by modifying other aspects of the assay, we developed a procedure that is sufficiently sensitive (0.34 micrograms/L) to allow measurement of trough (lowest inter-dose) cyclosporine concentrations in parotid saliva. Of 38 kidney-transplant patients, 35 had measurable concentrations in saliva (mean 8.3, SD 5.2 micrograms/L), and these correlated moderately with paired serum concentrations (r = 0.68, P less than 0.001). We believe that measurement of salivary cyclosporine may offer a simple way of estimating the free fraction of the drug in serum or plasma

  18. {sup 125}I-iomazenil-benzodiazepine receptor binding during psychological stress in rats

    Energy Technology Data Exchange (ETDEWEB)

    Fukumitsu, Nobuyoshi; Tsuchida, Daisuke; Ogi, Shigeyuki; Uchiyama, Mayuki; Mori, Yutaka [Jikei Univ., Tokyo (Japan). School of Medicine

    2002-05-01

    We investigated the changes in {sup 125}I-iomazenil ({sup 125}I-IMZ) benzodiazepine receptor (BZR) binding with psychological stress in a rat model. Six male Wistar rats were placed under psychological stress for 1 hour by using a communication box. No physical stress was not received. 1.85 MBq of {sup 125}I-IMZ was injected into the lateral tail vein and the rat was killed 3 hours later. Twenty-micormeter-thick sections of the brain were collected and % injected dose per body weight (% ID/BW) of eleven regions (frontal, parietal, temporal, occipital cortices, caudate putamen, accumubens nuclei, globus pallidus, amygdala, thalamus, hippocampus and hypothalamus) were calculated by autoradiography. The %ID/BW of rats which were placed under psychological stress was compared with that of 6 control rats. The %ID/BW of rats which were placed under psychological stress diffusely tended to show a reduction in {sup 125}I-IMZ-BZR binding. A significant decrease in BZR binding was observed in the hippocampus of the rats which were placed under psychological stress. {sup 125}I-IMZ-BZR binding tended to decrease throughout the brain. (author)

  19. Synthesis of 125 I - Salicyl Hydroxamic Acid for Urinary Bladder Imaging

    International Nuclear Information System (INIS)

    Ibrahim, I.T.; Abou EL Zahab, M.; Hamed, M.

    2015-01-01

    Salicylhydroxamic acid is a salicylate derivative. Radiolabeling of Salicyl hydroxamic acid ( SHA ) with iodine-125 may have considerable interest for imaging of urinary bladder. This study is aimed to optimize the radiolabeling yield of Salicyl hydroxamic with radio iodine (125-123) using chloramine - T (CAT) as an oxidizing agent with respect to factors that affect the reaction conditions such as SHA amount, CAT amount, reaction time and ph of the reaction mixture. In - vitro stability of the radiolabeled complex was checked and it was found to be stable for up to 24 h. 125 I-SHA was injected via intravenous administration routes into normal male Sprague – Dawley rats. Bio - distribution studies have revealed that 125 I-SHA was excreted in urine with extent that it could give a clear image for urinary bladder especially if the bladder it tightly closed. The amount of 125 I - Salicyl hydroxamic excreted was increased in case of giving potassium bicarbonate to rat before injection of 125 I-SHA. The result of biodistribution study of 125 I - SHA in experimental animal suggest ed the possibility of using 123 I-SHA to image the urinary bladder

  20. The preparation of 125I - gastrin I and 125 - minigastrin for medical diagnostics

    International Nuclear Information System (INIS)

    Byszewska-Szpocinska, E.; Markiewicz, A.

    2002-01-01

    Gastrin I G-17 and minigastrin G-13 were iodinated using direct methods with chloramin T and iodogen procedures and by indirect method with Bolton-Hunter reagent. 125 I - gastrin and 1 25 I - minigastrin were isolated from the iodination mixtures by gel filtration on Sephadex G-10 and Sephadex G-25 (PD-10 column) and by HPLC system (Lichrospher WP-300-RP-18 column). Radiochemical purity was shown by HPLC also. It was confirmed that iodogen procedure is the best for iodination of these peptides. 125 I - gastrin I obtained by this method with specific activity 80 μCi/nmol was homogeneous but iodination to higher specific activity (440μCi/nmol) caused appearance of two subfractions. 125 I - minigastrin with high and low specific activity were isolated by HPLC as the two forms (subfractions). It was shown that high performance liquid chromatography (HPLC) was the best method for isolation and purification of 125 I - gastrin I and 125 I - minigastrin. (author)

  1. N-(m-[125I]iodophenyl)maleimide: an agent for high yield radiolabeling of antibodies

    International Nuclear Information System (INIS)

    Khawli, L.A.; Van den Abbeele, A.D.; Kassis, A.I.

    1992-01-01

    In an effort to radiolabel antibodies, N-(m-[ 125 I]iodophenyl)maleimide (m-[ 125 I]IPM) was prepared by the demetallation of an N-[m-tri-(n-butyl)stannylphenyl]maleimide intermediate. The unlabeled intermediate was synthesized in ≥ 75% yield using a palladium catalyzed reaction of hexabutylditin with m-bromoaniline, followed by reaction with maleic anhydride and ring annulation. All products were confirmed by NMR and elemental analysis. Labeling with 125 I was carried out in a biphasic mixture containing chloramine-T (radiochemical yield ≥ 70%). Rabbit IgG modified with the heterobifunctional crosslinking agent N-succinimidyl-3-(2-pyridyldithio)propionate (SPDP) and bovine serum albumin were conjugated with m-[ 125 I]IPM (yield: 40 and 80%, respectively). In addition, m-[ 125 I]IPM was conjugated to rabbit IgG subunits (HL) in 70% yield. The in vitro stability of the radiolabeled proteins in serum showed < 1% deiodination over 24h. (author)

  2. Binding of 125I-labeled proteinases to plasma proteins in cystic fibrosis

    Energy Technology Data Exchange (ETDEWEB)

    Romeo, G; Parsons, M; Bossen, A; Blessing-Moore, J; Cavalli-Sforza, L L

    1979-09-01

    Samples of plasma or serum from 53 cystic fibrosis (CF) patients, 90 relatives of CF patients, and 159 controls have been incubated with porcine or bovine 125I-trypsin, electrophoresed on polyacrylamide gel, and autoradiographed. In these individuals, the main binding protein for 125I-trypsin has been shown to be alpha 2-macroglobulin (alpha 2M)> Using this method of analysis, no difference in electrophoretic migration of 125I-trypsin-alpha 2M complexes has been observed between CF ad control individuals. However, trypsin binding to IgG has been observed in 80% of CF patients, 30% of their mothers, 3% of controls, and in two patients affected with pancreatitis. Experimental evidence indicates that binding of trypsin to IgG occurs through the Fab portion of the molecule.

  3. Preparation and Evaluation of (125I) Daunorubicin as a Potential Agent for Tumor Detection and radiotherapy

    International Nuclear Information System (INIS)

    El Amir, M.A.; Farouk, N.; Ramadan, H.E.; El Bayomy, A.S.

    2012-01-01

    In this study, the optimization of daunorubicin labeling with iodine-125 and its biological evaluation were described. Daunorubicin was labeled via direct electrophilic substitution using chloramine-T as oxidizing agent. The optimum amounts of reactants were: 40μg daunorubicin, 30μg Chloramine-T and ∼ 19 KBq carrier free Na 125 I. The labeled daunorubicin was stable for more than 24 hours. Results of the in-vivo evaluation revealed that the tracer, [ 125 I] daunorubicin, tends to localize in tissues with high proliferation rate with preferential accumulation in cancerous tissues. Imaging should be carried at 3 hours post injection. The in-vitro cell growth inhibition assay showed that the effect of [ 125 I] Daunorubicin was stronger than the effect of cold daunorubicin which strongly suggested that its cytotoxicity was mainly due to radiotoxicity rather than chemotherapeutic activity.

  4. Analysis of 125I-[Tyr3] octreotide receptors of NCI-H466 cell line

    International Nuclear Information System (INIS)

    Sun Junjie; Fan Wo; Xu Yujie; Zhang Youjiu; Zhu Ran

    2002-01-01

    Objective: To study the affinity of small cell lung carcinoma to [Tyr 3 ] octreotide (TOC). Methods: Taking 125 I-[Tyr 3 ] octreotide (labeled by chloramine-T method), as the ligand, small cell lung carcinoma NCI-H466 cell line was inspected for the receptor-binding points and affinity constant. Results: The radio-chemical purity of 125 I-TOC purified through sephadex G-10 was higher than 95%. Receptor analysis study showed that the expression of somatostatin receptors on NCI-H446 cells was numerous (Bmax = 1.17 x 10 5 /cell) with strong affinity to 125 I-TOC (Kd = 0.56 nM). Conclusion: Labeled TOC could be used for small cell lung carcinoma receptor imaging and radio-pharmaceutical therapy

  5. 99mTc-albumin can replace 125I-albumin to determine plasma volume repeatedly

    DEFF Research Database (Denmark)

    Bonfils, Peter K; Damgaard, Morten; Stokholm, Knud H

    2012-01-01

    OBJECTIVE: Plasma volume assessment may be of importance in several disorders. The purpose of the present study was to compare the reliability of plasma volume measurements by technetium-labeled human serum albumin ((99m)Tc-HSA) with a simultaneously performed plasma volume determination...... with iodine-labeled human serum albumin ((125)I-HSA). MATERIALS AND METHODS: In 15 healthy volunteers, simultaneous plasma volume measurements with (99m)Tc-HSA and (125)I-HSA were performed after ½ hour in the supine position. Blood samples were obtained 10, 15, 20, and 30 minutes after the injection...... for accurate retropolation from the plasma counts to time zero to correct for leakage of the isotopes from the circulation. RESULTS: The mean difference (bias) between plasma volume measured with (125)I-albumin and (99m)Tc-albumin was 8 ml (0.1 ml/kg) with limits of agreement (bias ±1.96 SD) ranging from -181...

  6. Development of thyroid monitoring system for the measurement of 125I

    International Nuclear Information System (INIS)

    Sankhla, Rajesh; Singh, I.S.; Rao, D.D.; Pradeepkumar, K.S.

    2015-01-01

    Iodine-125 has gained wide acceptance in medical science for diagnosis and therapeutic applications. A considerable number of radiation workers of BARC and BRIT are involved in the production of 125 I and preparation of radio immunoassay (RIA) kits to meet medical requirement of the country. A state of the art Thyroid Monitoring System incorporated with 51 mm diameter x 3 mm thick NaI(Tl) detector is developed for in-vivo monitoring of 125 I in radiation workers handling this radioisotope. The developed system also has provision to accommodate variable body sizes (child to adult). This paper presents the different aspects of the system and its calibration using IAEA neck phantom for estimation of thyroidal content of 125 I. (author)

  7. Radioligand assays: methods and application. 5. /sup 125/I-monoidoinsulin: preparation, immunological and biological characterization

    Energy Technology Data Exchange (ETDEWEB)

    Besch, W; Woltanski, K P; Knospe, S; Ziegler, M; Keilacker, H [Zentralinstitut fuer Diabetes, Karlsburg (German Democratic Republic)

    1980-04-01

    A reproducible method for preparation of /sup 125/I-monoiodoinsulin with fully biological activity was developed. Monoiodoinsulin has been prepared from a heterogeneous /sup 125/I iodination mixture by anion exchange chromatography on DEAE-Sephadex A-25 without using any gradient elution technique. The specific radioactivity of /sup 125/I-monoiodoinsulin was calculated to 14.3 +- 0.8 TBq/g, i.e. an iodine content of 1.04 +- 0.06 atoms per molecule of insulin. Monoiodoinsulin was indistinguishable from native insulin with respect to binding to guinea pig anti-insulin serum, and to insulin receptors of isolated rat adipocytes. The biological potency (96.5 +- 7.5 per cent of the immunoreactive insulin activity) determined by the conversion of (/sup 14/C/sub 1/)-D-glucose to /sup 14/CO/sub 2/ in vitro by rat fat cells was not significantly different from that of native insulin.

  8. Investigation of internalization and cytotoxicity of 125I-[Tyr3]-octreotide in NCI-H446 cell line

    International Nuclear Information System (INIS)

    Sun Junjie; Fan Wo; Xu Yujie; Zhang Youjiu; Zhu Ran; Hu Mingjiang

    2004-01-01

    Objective: To investigate the [Tyr 3 ]-octreotide (TOC) internalizing capacity of NCI-H446 cell line, and the cytotoxicity of 125 I-TOC in NCI-H446 cell line. To assess the therapeutic radiopharmaceutical potentiality of 125 I-TOC for the somatostatin receptor (SSTR) positive tumor. Methods: NCI-H446 cells were incubated together with 125 I-TOC for different periods of time, the amount of internalized 125 I-TOC and the 125 I-TOC bound on the cellular nucleus were detected with γ counter, respectively. The viability of the cells was analyzed by a 3-(4,5-dimethylthiazol-2-yl)-2,5-diphenyltetrazolium bromide (MTT) assay at different time points with various doses of 125 I-TOC, free 125 I and TOC. Results: 125 I-TOC was internalized into the nucleus and bound on the nucleus in a time-dependent manner. 125 I-TOC bound on the nucleus increased to the highest level at 24 h, the amount of nucleus bound 125 I-TOC at 24 h was 7 times higher than that at 0.5 h. Cytotoxicity of 125 I-TOC in SSTR positive NCI-H446 cells was also dose- and time-dependent. The supreme effect of cytotoxicity was found at 96 h with 74 kBq 125 I-TOC, the survival ratio of cells was reduced to (44.8 ± 7.2)%. Conclusions: 125 I-TOC can be internalized into SSTR positive cells mediated by SSTR. The NCI-H446 cells can be killed by Auger electron emitting from 125 I-TOC. Effect of cytotoxicity showed dose- and time-dependent

  9. Inulin-125I-tyramine, an improved residualizing label for studies on sites of catabolism of circulating proteins

    International Nuclear Information System (INIS)

    Maxwell, J.L.; Baynes, J.W.; Thorpe, S.R.

    1988-01-01

    Residualizing labels for protein, such as dilactitol-125I-tyramine (125I-DLT) and cellobiitol-125I-tyramine, have been used to identify the tissue and cellular sites of catabolism of long-lived plasma proteins, such as albumin, immunoglobulins, and lipoproteins. The radioactive degradation products formed from labeled proteins are relatively large, hydrophilic, resistant to lysosomal hydrolases, and accumulate in lysosomes in the cells involved in degradation of the carrier protein. However, the gradual loss of the catabolites from cells (t1/2 approximately 2 days) has limited the usefulness of residualizing labels in studies on longer lived proteins. We describe here a higher molecular weight (Mr approximately 5000), more efficient residualizing glycoconjugate label, inulin-125I-tyramine (125I-InTn). Attachment of 125I-InTn had no effect on the plasma half-life or tissue sites of catabolism of asialofetuin, fetuin, or rat serum albumin in the rat. The half-life for hepatic retention of degradation products from 125I-InTn-labeled asialofetuin was 5 days, compared to 2.3 days for 125I-DLT-labeled asialofetuin. The whole body half-lives for radioactivity from 125I-InTn-, 125I-DLT-, and 125I-labeled rat serum albumin were 7.5, 4.3, and 2.2 days, respectively. The tissue distribution of degradation products from 125I-InTn-labeled proteins agreed with results of previous studies using 125I-DLT, except that a greater fraction of total degradation products was recovered in tissues. Kinetic analyses indicated that the average half-life for retention of 125I-InTn degradation products in tissues is approximately 5 days and suggested that in vivo there are both slow and rapid routes for release of degradation products from cells

  10. Optimization of the synthesis of a high specific activity 125 I-labelled hapten for radioimmunoassays

    International Nuclear Information System (INIS)

    Suarez, C.; Simon, M.A.; Paz, D.; Romero del Hombrebueno, B.

    1994-01-01

    In this first report it is described the synthesis, separation and purification of the 2-radioiodinated histamine ''125 I-labelled histamine by a mixed anhydride reaction. About 75% incorporation of I''1125, from Na''125, I, was achieved with a molecular ratio of 1:1 mixed anhydride:histamine. The radiochemical purity of the conjugate by TLC was >99% and its theoretical specific activity, 3850 mu Ci/mug. Dissolved in ethanol and held at -20 degree centigree under darkness decomposition on storage did not exceed 1% per month

  11. (E)-[125I]-5-AOIBV: a SPECT radioligand for the vesicular acetylcholine transporter

    International Nuclear Information System (INIS)

    Emond, Patrick; Mavel, Sylvie; Zea-Ponce, Yolanda; Kassiou, Michael; Garreau, Lucette; Bodard, Sylvie; Drossard, Marie-Laure; Chalon, Sylvie; Guilloteau, Denis

    2007-01-01

    The premise that, over the course of Alzheimer's disease (AD), changes in the levels of the vesicular acetylcholine transporter (VAChT) occur in parallel with changes to other cholinergic marker proteins provides the basis for the applicability of benzovesamicol derivatives as radioligands for AD studies by single photon emission computed tomography or positron emission tomography. We report the synthesis of enantiopure benzovesamicol derivatives: (R,R) or (S,S)-(E)-2-hydroxy-5-(3-iodoprop-2-en-1-oxy)-3- (4-phenylpiperidino)tetralin [(R,R)-AOIBV: K d =0.45 nM or (S,S)-5-AOIBV: K d =4.3 nM] and their corresponding tributyltin precursors for radioiodination. (R,R or S,S)-5-AOIBV was labeled with iodine-125 from their corresponding n-tributyltin precursors. Both compounds were obtained with radiochemical and optical purity greater than 97% and in radiochemical yields ranging 34-36%. To determine if these compounds could provide an advantage when compared to [ 125 I]-iodo benzovesamicol (IBVM), IBVM was also labeled and used as the reference compound in all ex vivo experiments. Ex vivo biodistribution experiments in rats revealed that [ 125 I]-(R,R)-5-AOIBV displayed the most suitable pharmacological profile as the radioactivity distribution corresponded well with the known VAChT brain density. Moreover, pre-injection of vesamicol prevented the uptake of [ 125 I]-(R,R)-5-AOIBV in striatum, cortex and hippocampus, demonstrating selectivity for the VAChT. However, even if time activity curves of [ 125 I]-(R,R)-5-AOIBV confirmed that this compound could be used to visualize the VAChT in vivo, at each point of the kinetic study, [ 125 I]-(R,R)-5-AOIBV showed a lower specific binding compared to [ 125 I]-IBVM. These results made [ 125 I]-( R,R)-5-AOIBV inferior to [ 125 I]-IBVM for the VAChT exploration in vivo

  12. (E)-[{sup 125}I]-5-AOIBV: a SPECT radioligand for the vesicular acetylcholine transporter

    Energy Technology Data Exchange (ETDEWEB)

    Emond, Patrick [INSERM U619, 37000 Tours (France); Universite Francois-Rabelais de Tours, CHRU, Hopital Bretonneau, Service de Medecine nucleaire, 37000 Tours (France); Mavel, Sylvie [INSERM U619, 37000 Tours (France); Universite Francois-Rabelais de Tours, CHRU, Hopital Bretonneau, Service de Medecine nucleaire, 37000 Tours (France)], E-mail: sylvie.mavel@univ-tours.fr; Zea-Ponce, Yolanda [INSERM U619, 37000 Tours (France); Universite Francois-Rabelais de Tours, CHRU, Hopital Bretonneau, Service de Medecine nucleaire, 37000 Tours (France); Kassiou, Michael [Discipline of Medical Radiation Sciences, Brain and Mind Research Institute, University of Sydney, NSW 2050 (Australia); School of Chemistry, University of Sydney, NSW 2006 (Australia); Garreau, Lucette; Bodard, Sylvie; Drossard, Marie-Laure; Chalon, Sylvie; Guilloteau, Denis [INSERM U619, 37000 Tours (France); Universite Francois-Rabelais de Tours, CHRU, Hopital Bretonneau, Service de Medecine nucleaire, 37000 Tours (France)

    2007-11-15

    The premise that, over the course of Alzheimer's disease (AD), changes in the levels of the vesicular acetylcholine transporter (VAChT) occur in parallel with changes to other cholinergic marker proteins provides the basis for the applicability of benzovesamicol derivatives as radioligands for AD studies by single photon emission computed tomography or positron emission tomography. We report the synthesis of enantiopure benzovesamicol derivatives: (R,R) or (S,S)-(E)-2-hydroxy-5-(3-iodoprop-2-en-1-oxy)-3- (4-phenylpiperidino)tetralin [(R,R)-AOIBV: K{sub d}=0.45 nM or (S,S)-5-AOIBV: K{sub d}=4.3 nM] and their corresponding tributyltin precursors for radioiodination. (R,R or S,S)-5-AOIBV was labeled with iodine-125 from their corresponding n-tributyltin precursors. Both compounds were obtained with radiochemical and optical purity greater than 97% and in radiochemical yields ranging 34-36%. To determine if these compounds could provide an advantage when compared to [{sup 125}I]-iodo benzovesamicol (IBVM), IBVM was also labeled and used as the reference compound in all ex vivo experiments. Ex vivo biodistribution experiments in rats revealed that [{sup 125}I]-(R,R)-5-AOIBV displayed the most suitable pharmacological profile as the radioactivity distribution corresponded well with the known VAChT brain density. Moreover, pre-injection of vesamicol prevented the uptake of [{sup 125}I]-(R,R)-5-AOIBV in striatum, cortex and hippocampus, demonstrating selectivity for the VAChT. However, even if time activity curves of [{sup 125}I]-(R,R)-5-AOIBV confirmed that this compound could be used to visualize the VAChT in vivo, at each point of the kinetic study, [{sup 125}I]-(R,R)-5-AOIBV showed a lower specific binding compared to [{sup 125}I]-IBVM. These results made [{sup 125}I]-( R,R)-5-AOIBV inferior to [{sup 125}I]-IBVM for the VAChT exploration in vivo.

  13. 3-(/sup 125/I)iodo-4-hydroxyphenobarbitone for use in radioimmunoassay

    Energy Technology Data Exchange (ETDEWEB)

    Mason, P.A.; Law, B. (Home Office Central Research Establishment, Aldermaston (UK))

    1982-03-01

    A method is described for the preparation of a barbiturate derivative, 3-iodo-4-hydroxyphenobarbitone, labelled with (/sup 125/I)iodine. The structure of the compound was confirmed by synthesis and purification of the (/sup 127/I)iodine derivative followed by mass spectral studies. The (/sup 125/I)iodine labelled barbiturate has proved to be chemically stable and has been shown to bind to a barbiturate antiserum. It should, therefore, prove to be very useful for the development of a radioimmunoassay for barbiturates.

  14. An instrument for measurement of 125I with automatic efficiency correction

    International Nuclear Information System (INIS)

    Holford, R.M.

    1979-10-01

    Counting efficiencies for 125 I are often uncertain because of self-absorption of the low-energy radiation. A special purpose instrument, AEP-5285, has been designed to simplify the measurement of 125 I activities using a known technique in which the observed counting rate is compensated for self-absorption and any other uncertainties in the counting efficiency by making use of the coicidence properties of the radiation. The instrument contains pulse amplifiers, discriminators to define the energy regions of interest, and operational amplifier circuits to perform the necessary calculations automatically, and it displays an estimate of the source activity in becquerels. (auth)

  15. Synthesis of radioiodinated N-succinimidyl 3-[125I] iodobenzoate

    International Nuclear Information System (INIS)

    Li Junling; Wang Lihua; Zhang Lan; Tian Haibin; Wang Yongxian

    2003-01-01

    N-Succinimidyl 3-(tri-n-butylstannyl) benzoate (ATE) was radioiodinated using Iodogen as oxidant and useful conjugate S 125 IB of labeling proteins was obtained. ATE and Iodogen affecting labeling proteins were successfully isolated from S 125 IB by Sep-Pak silica. The labeling efficiency was more than 93%. Several factors affecting labeling such as labeling time, the amount of Iodogen and the mole ratio of ATE to Na 125 I, were studied. The better labeling conditions were obtained as follows: mole ratio of ATE to Na 125 I=6:1, Iodogen=7 μg, labeling time=5 min in room temperature

  16. Selective binding of 2-[{sup 125}I]iodo-nisoxetine to norepinephrine transporters in the brain

    Energy Technology Data Exchange (ETDEWEB)

    Kung, M.-P.; Choi, Seok-Rye; Hou, Catherine; Zhuang, Z.-P.; Foulon, Catherine; Kung, Hank F. E-mail: kunghf@sunmac.spect.upenn.edu

    2004-07-01

    A radioiodinated ligand, (R)-N-methyl-(2-[{sup 125}I]iodo-phenoxy)-3-phenylpropylamine, [{sup 125}I]2-INXT, targeting norepinephrine transporters (NET), was successfully prepared. A no-carrier-added product, [{sup 125}I]2-INXT, displayed a saturable binding with a high affinity (K{sub d}=0.06 nM) in the homogenates prepared from rat cortical tissues as well as from LLC-PK{sub 1} cells expressing NET. A relatively low number of binding sties (B{sub max}=55 fmol/mg protein) measured with [{sup 125}I]2-INXT in rat cortical homogenates is consistent with the value reported for a known NET ligand, [{sup 3}H]nisoxetine. Competition studies with various compounds on [{sup 125}I]2-INXT binding clearly confirmed the pharmacological specificity and selectivity for NET binding sites. Following a tail-vein injection of [{sup 125}I]2-INXT in rats, a good initial brain uptake was observed (0.56% dose at 2 min) followed by a slow washout from the brain (0.2% remained at 3 hours post-injection). The hypothalamus (a NET-rich region) to striatum (a region devoid of NET) ratio was 1.5 at 3 hours post-i.v. injection. Pretreatment of rats with nisoxetine significantly inhibited the uptake of [{sup 125}I]2-INXT (70-100% inhibition) in locus coeruleus, hypothalamus and raphe nuclei, regions known to have a high density of NET; whereas escitalopram, a serotonin transporter ligand, did not show a similar effect. Ex vivo autoradiography of rat brain sections of [{sup 125}I]2-INXT (at 3 hours after an i.v. injection) displayed an excellent regional brain localization pattern corroborated to the specific NET distribution in the brain. The specific brain localization was significantly reduced by a dose of nisoxetine pretreatment. Taken together, the data suggest that [{sup 123}I]2-INXT may be useful for mapping NET binding sites in the brain.

  17. Dosimetric effectiveness in implants with distinct HO166-seed distribution in prostate

    International Nuclear Information System (INIS)

    Braga, Viviane V. B.; Campos, Tarcísio P. R.

    2017-01-01

    Currently, there is a need to produce new therapeutic techniques for the treatment of prostate tumors, considering the high incidence of the disease and significant morbidity rates associated with surgery and radiotherapy. Simulations in brachytherapy produce essential information about the efficiency and dosimetric efficacy compared to other techniques. Computational simulation by Monte Carlo method has been used to evaluate the absorbed dose and effective dose in radiotherapy and radiology. Virtual, analytical or voxelized phantoms are useful in the internal assessment of the spatial distribution of absorbed dose. This study estimated the efficiency of dosimetry by parameters of merit generated from volumetric distributions of absorbed doses simulating various spatial distributions of Ho-166 seeds in a prostate model. A computer model of voxels was developed, using the code SISCODES (Computational System for Dosimetry by Neutrons and Photons by Stochastic Methods applied to radiology and radiotherapy), representative of a real physical simulator predefined as a calibration method. The virtual model reproduced a cubic box, filled with muscle equivalent tissue (TE), where a 5-cm diameter ball with TE-prostate was positioned 2-cm from the air interface. A Ho-166 seed distribution, produced by 16 filet-implants distributed regularly (10-mm pitch) containing 04 separate 8-mm seeds, was employed. Two pitch were considered: 9 and 10 mm, with same distance between seed in a fillet. Based on SISCODE database of chemical composition of tissues and nuclear data, The code allowed the association of nuclear and chemical data to the voxels of the model, by the selection of the tissue of each voxel, as well as the positioning of the sources and their spatial distribution and spectra. The code MCNP5 simulated the transport of photons and electrons in the model, generating the energy deposited per unit mass in each voxel for photons in MeV.g-1 and energy absorbed in MeV for beta

  18. Dosimetric effectiveness in implants with distinct HO166-seed distribution in prostate

    Energy Technology Data Exchange (ETDEWEB)

    Braga, Viviane V. B.; Campos, Tarcísio P. R., E-mail: Vitoriabraga06@gmail.com, E-mail: tprcampos@yahoo.com.br [Universidade Federal de Minas Gerais (UFMG), Belo Horizonte, MG (Brazil). Departamento de Engenharia Nuclear

    2017-07-01

    Currently, there is a need to produce new therapeutic techniques for the treatment of prostate tumors, considering the high incidence of the disease and significant morbidity rates associated with surgery and radiotherapy. Simulations in brachytherapy produce essential information about the efficiency and dosimetric efficacy compared to other techniques. Computational simulation by Monte Carlo method has been used to evaluate the absorbed dose and effective dose in radiotherapy and radiology. Virtual, analytical or voxelized phantoms are useful in the internal assessment of the spatial distribution of absorbed dose. This study estimated the efficiency of dosimetry by parameters of merit generated from volumetric distributions of absorbed doses simulating various spatial distributions of Ho-166 seeds in a prostate model. A computer model of voxels was developed, using the code SISCODES (Computational System for Dosimetry by Neutrons and Photons by Stochastic Methods applied to radiology and radiotherapy), representative of a real physical simulator predefined as a calibration method. The virtual model reproduced a cubic box, filled with muscle equivalent tissue (TE), where a 5-cm diameter ball with TE-prostate was positioned 2-cm from the air interface. A Ho-166 seed distribution, produced by 16 filet-implants distributed regularly (10-mm pitch) containing 04 separate 8-mm seeds, was employed. Two pitch were considered: 9 and 10 mm, with same distance between seed in a fillet. Based on SISCODE database of chemical composition of tissues and nuclear data, The code allowed the association of nuclear and chemical data to the voxels of the model, by the selection of the tissue of each voxel, as well as the positioning of the sources and their spatial distribution and spectra. The code MCNP5 simulated the transport of photons and electrons in the model, generating the energy deposited per unit mass in each voxel for photons in MeV.g-1 and energy absorbed in MeV for beta

  19. Upregulation of [125I] CGP42112 binding in the rat brainstem following nodose ganglionectomy

    International Nuclear Information System (INIS)

    Roulston, C.L.; Lawrence, A.J.; Jarrott, B.; Widdop, R.E.

    1999-01-01

    Full text: [ 125 I] CGP42112 is a specific ligand which has been used to demonstrate the presence of angiotensin AT 2 receptors in peripheral and brain tissue, although [ 125 I] CGP42112 also binds to a non-angiotensin II (Ang II) site. In the present study we have examined [ 125 I] CGP42112 binding in the brainstem following nodose ganglionectomy using autoradiography. Male spontaneously hypertensive rats (SHR) and Wistar Kyoto (WKY) rats underwent unilateral nodose ganglionectomy or sham operation (anaesthetised with methohexitone, 60mg/kg ip). Following a 14 day recovery period, animals were killed and slide mounted brainstem sections (14μm) were prepared and incubated in the presence of either [ 125 I] (Sar 1 Ile 8 )Ang II (0.5nM), [ 125 I] CGP42112 (0.3nM) or [ 3 H] PKI11195 (3nM, a marker for activated microglia). Following incubation, slides were apposed to film for 10 days. Specific binding was determined in adjacent sections by co-incubations with either the AT 1 receptor antagonist losartan, the AT 2 receptor antagonist PD 123319, Ang II or PKI11195 (all at 10μM). In the ganglionectomised groups, there were significant reductions in [ 125 I] (Sar 1 Ile 8 )Ang II binding on the denervated side of the nucleus of the solitary tract (NTS) by 30 ± 2 % (n=5, P 125 I] CGP42112 binding in the NTS revealed an AT 2 receptor component which was displaceable by PD 123319 and Ang II (∼60%), and a non-Ang II component (∼40%). Nodose ganglionectomy increased the density of [ 125 I] CGP42112 binding on the denervated side of the NTS by 55 ± 3 % (n=5, P 125 I] CGP42112 binding in the NTS of the ganglionectomised groups was comprised of a greater non-Ang II component than in the sham group, since only ∼30% was displaced by PD123319 and Ang II. [ 125 I] CGP42112 also revealed high binding density in the dorsal motor nucleus and the nucleus ambiguus on the denervated side in both SHR and WKY rats. This binding was absent in shams and was only ∼30-40% displaceable

  20. Study on the thyroid function of thoroughbred horses by means of 'in vitro' 125I-T3 modified and 125I-T4 tests

    International Nuclear Information System (INIS)

    Martin, B.W. de

    1975-01-01

    Sera of 71 animals, divided in groups of males and females, in repose and after activity were studied. The method to establish the percentage of the 125 I-lyothyronine retention in resin (Test 125 I-T 3 or T 3 ) was modified by the use of 0.2 ml of serum on the resin column, after addition of the marked hormone. This modification served to prove that thoroughbred equines show binding of the I-lyothyronine to the serum four times reduced, indicating, therefore, that these animals have four times more ligation sites of triidothyronin saturation in the serum, when compared with the results obtained from human beings. The variance analysis applied to the T 3 Test showed no significant results at the 95% level as regards to activity. For the 71 animals, the author has found an average of 50.30% of the 125 I-Lyothyronine in resin retention, being the confidence interval for this group between 48.75% and 51.85% to a 95% confidence coefficient. Evaluating the results of the T 4 Test by means of the variance analysis, we noticed that the male and female groups in repose differed statistically from the groups after activity to a 95% confidence coefficient. The author has grouped the results of the T 4 Test of 32 equines, 18 males and 14 females, in repose, obtaining an average of 0.61 mcg and 0.51 mcg and 0.71 mcg T 4 /100 ml as confidence interval to a 95% confidence coefficient. We have listed 39 results of T 4 Test, being 23 males and 61 Females, after activity, obtaining an average of 2.01 mcg of thyroxin by 100 ml of serum and 1.72 mcg and 2.30 T 4 /100 ml as confidence interval to a 95% confidence coefficient

  1. Highly efficient method for 125I-radiolabeling of biomolecules using inverse-electron-demand Diels-Alder reaction.

    Science.gov (United States)

    Choi, Mi Hee; Shim, Ha Eun; Yun, Seong-Jae; Kim, Hye Rim; Mushtaq, Sajid; Lee, Chang Heon; Park, Sang Hyun; Choi, Dae Seong; Lee, Dong-Eun; Byun, Eui-Baek; Jang, Beom-Su; Jeon, Jongho

    2016-04-19

    In this report, we present a rapid and highly efficient method for radioactive iodine labeling of trans-cyclooctene group conjugated biomolecules using inverse-electron-demand Diels-Alder reaction. Radioiodination reaction of the tetrazine structure was carried out using the stannylated precursor 2 to give 125 I-labeled azide ([ 125 I]1) with high radiochemical yield (65±8%) and radiochemical purity (>99%). For radiolabeling application of [ 125 I]1, trans-cyclooctene derived cRGD peptide and human serum albumin were prepared. These substrated were reacted with [ 125 I]1 under mild condition to provide the radiolabeled products [ 125 I]6 and [ 125 I]8, respectively, with excellent radiochemical yields. The biodistribution study of [ 125 I]8 in normal ICR mice showed significantly lower thyroid uptake values than that of 125 I-labeled human serum albumin prepared by a traditional radiolabeling method. Therefore [ 125 I]8 will be a useful radiolabeled tracer in various molecular imaging and biological studies. Those results clearly demonstrate that [ 125 I]1 will be used as a valuable prosthetic group for radiolabeling of biomolecules. Copyright © 2016 Elsevier Ltd. All rights reserved.

  2. Staff dose of hospitalization in the treatment of patients in ophthalmic brachytherapy with 125 I

    International Nuclear Information System (INIS)

    Terron Leon, J. A.; Gomez Palacios, M.; Moreno Reyes, J. C.; Perales Molina, A.

    2013-01-01

    The objective of this work, therefore, has been the evaluation of the dose levels which nursing staff can receive in care for ophthalmic brachytherapy patients treated with 125 I from measurements made on the same, evaluating, in an experimental way, job security following the PR rules laid down for these treatments. (Author)

  3. Cortisol decreases 2[125I] iodomelatonin binding sites in the duck thymus

    International Nuclear Information System (INIS)

    Poon, A.M.S.; Liu, Z.M.; Tang, F.; Pang, S.F.

    1994-01-01

    The immunosuppressive effect of chronic glucocorticoid treatment on 2[ 125 I] iodomelatonin binding in the duck thymus was studied. Two-week-old ducks were injected intraperitoneally with either 1 mg of cortisol per day (experimental group) or an equivalent volume of vehicle (control group) in the middle of the light period for seven days. 2[ 125 I] iodomelatonin binding assays were performed on thymic membranes. Cortisol injection reduced the body weight gain, size of the bursa of Fabricius and absolute weights of the primary lymphoid organs but had no effect on the spleen weights. The relative weights of the spleen were increased while those of the primary lymphoid organs were unchanged. The density of the thymus 2[ 125 I] iodomelatonin binding sites was decreased while the affinity was not affected. The modulation of the thymic 2[ 125 I] iodomelatonin binding sites by changes in the immune status of the duck suggests that these binding sites represent physiologically relevant melatonin receptors and that melatonin exerts its action on the lymphoid tissues directly. The authors findings support the hypothesis that the thymus is the target site for the immunomodulatory interactions between the pineal melatonin and the adrenal steroids. A possible inhibitory influence of adrenal steroids on the immuno-enhancing effect of melatonin is also suggested. 34 refs., 3 tabs

  4. Preparation of 125I-protein A usable for up to 10 months in immunoassays

    DEFF Research Database (Denmark)

    Dyrberg, T; Billestrup, Nils

    1984-01-01

    weeks resulted in a moderate decrease in maximal binding to immunoglobulin (from 91% to 64%), in TCA precipitable radioactivity (from 97% to 80%) and an approx. 30% decrease in the ability to detect cell bound immunoglobulin. It is concluded that gel electrophoretic purification of 125I...

  5. Studies on the influence on the excretory kinetics of 125I-Adipiodon

    International Nuclear Information System (INIS)

    Koenig, H.

    1982-01-01

    The possibility of influencing distribution and elimination of 125 I-Adipiodon ( 125 I-iodipamide meglumine) by a preceding administration of Falignost (iomeglamic acid) as well as by dose-time variants of the mechanic intravenous application of contrast medium was tested in 55 anicteric and 2 icteric patients within clinically indicated cholegraphic examination with the aim of methodical optimization. For the detection of principal regularities comparative studies with 125 I-Adipiodon and Falignost in rats as well as examinations of protein binding of 125 I-Adipiodon in the plasm of rats and in the plasm and in mixed serum (application in vitro) of patients by gel filtration with Epidex B 2 coarse and batch operation on more than 1,200 samples were additionally carried out. For combined cholecystography with intravenous infusion of Adipiodon in immediate temporal connection with the administration of Falignost a reduced visibility of the biliary tract in the X-ray picture is not to be expected as the consequence of the mutual influence of the contrast media. For intact excretory function of liver and kidneys the combined cholecystography can be recommended. The effects of a dose increase, of protracted infusion of Adipiodon and of the intravenous administration of 0.01 g metroclopramide on the demonstration of the biliary tract in the intravenous cholegram are outlined. (author)

  6. The binding of 125I-fibrinogen to blood platelets in patients with chronic uraemia

    International Nuclear Information System (INIS)

    Komarnicki, M.; Zozulinska, M.; Zawilska, K.

    1987-01-01

    The binding of 125 I-fibrinogen to blood platelets was assessed in 41 patients with chronic uremia. The study was performed in three groups of subjects: treated conservatively, with hemodialysis and with peritoneal dialysis. Platelets from uremic patients were shown to be more susceptible to fibrinogen binding than platelets from healthy subjects. (author)

  7. Synthesis of the 123I- and 125I-labeled cholinergic nerve marker (-)-5-iodobenzovesamicol

    International Nuclear Information System (INIS)

    Van Dort, M.E.; Jung, Y.-W.; Gildersleeve, D.L.; Hagen, C.A.; Kuhl, D.E.; Wieland, D.M.

    1993-01-01

    The highly toxic curaremimetic and cholinergic neuron marker (-)-5-iodobenzovesamicol (IBVM) has been labeled with iodine-125 and iodine-123. [ 125 I]IBVM, suitable for animal distribution and ex vivo autoradiographic studies, was synthesized by solid-state exchanger; isolated yields were 65-89% with specific activities in the range of 130-200 Ci/mmol. The synthesis of no-carrier-added (-)-5-[ 125 I]IBVM from the corresponding chiral (-)-5-(tri-n-butyltin) derivative using Na 125 I was evaluated using the oxidants H 2 O 2 , peracetic acid and chloramine-T. Both peracetic acid and chloramine-T gave good yields (70-95%). However, when Na 123 I was utilized, acceptable yields of [ 123 I]IBVM were obtained only with chloramine-T. Distribution analyses of [ 125 I]IBVM and [ 123 I]IBVM in mice 4 h following intravenous administration show essentially equivalent concentrations of the two tracers in the four brain regions sampled. The exceptionally high specific activity of [ 123 I]IBVM has made possible the evaluation of this radiotracer in humans. (Author)

  8. Study on labelling methods of 125I-RC-160 and its biodistribution in animals

    International Nuclear Information System (INIS)

    Wang Jing; Wang Xiqing; Wang Liangang; Li Fujun; Deng Jinglan

    2002-01-01

    A method for the iodination of peptide RC-160 with high efficiency was developed. RC-160 was iodinated with N-bromosuccinimide (NBS) as oxidant, the conventional chloramine T (Ch-T) method was used as control. The labelling condition of NBS method was optimized and radiolabelled conjugate 125 I-RC-160 was assessed as follows: no further purification was needed, the measured labelling yield of 125 I-RC-160 was 92% and the specific activity was 1.95 x 10 12 Bq/m mol. The yield increased as the amount of NBS increased. The optimal ratio of RC-160 (μg): 125 I (MBq): NBS(μg) was 3:7.4:1. For Ch-T method, the labelling yield is 56% and specific activity was 0.65 x 10 12 Bq/m mol; but after purification by SepPak-C 18 , the labelling yield may reach as high as 92%. 1h after injection, radioactivity in blood decreased by 87.2%. No obvious concentration of 125 I-RC-160 in thyroid or kidney was observed

  9. Human platelet ( sup 125 I)R-DOI binding sites. Characterization by in vitro autoradiography

    Energy Technology Data Exchange (ETDEWEB)

    Himeno, A.; Saavedra, J.M. (National Institute of Mental Health, Bethesda, MD (USA))

    1990-02-01

    We quantified binding sites for 2,5-dimethoxy-4-iodo-phenylisopropylamine (DOI), a 5-HT2 agonist and hallucinogen, in human platelets. We incubated sections from human platelet pellets with ({sup 125}I)R-DOI with or without 1 mumol/L ketanserin, followed by autoradiography and computerized microdensitometry. We corrected the values of binding density by the protein content of each section with a densitometric protein assay. The present method revealed a single class of high affinity binding sites for ({sup 125}I)R-DOI, with a Kd of 6.4 +/- 0.7 nmol/L and a Bmax of 100 +/- 10 fmol/mg protein. Kd and Bmax for ({sup 125}I)R-DOI determined by the classical membrane binding assay, were 2.7 +/- 0.4 nmol/L and 100 +/- 10 fmol/mg protein, respectively. The present method is precise, very sensitive, and allows the characterization of ({sup 125}I)R-DOI binding in sections obtained from as little as 3 ml of blood. Standardization is possible after correction by the protein content of each individual section.

  10. Preparation of a 125I labeled derivative of penicillin to be used for radioimmunoassay

    International Nuclear Information System (INIS)

    Wal, J.-M.; Kann, Guy; Centre National de Recherches Zootechniques

    1975-01-01

    A 125 I-BSA Penicilloyl conjugate was prepared by coupling penicillin G to Bovine Serum Albumine previously labeled with iodine-125. The reaction of fixation by covalent binding was made in alkaline solution without the use of carbodiimide. Immunoreactivity and specific activity of this labeled conjugate enable radioimmunoassay of penicilloyl groups [fr

  11. Absolute quantitative autoradiography of low concentrations of [125I]-labeled proteins in arterial tissue

    International Nuclear Information System (INIS)

    Schnitzer, J.J.; Morrel, E.M.; Colton, C.K.; Smith, K.A.; Stemerman, M.B.

    1987-01-01

    We developed a method for absolute quantitative autoradiographic measurement of very low concentrations of [ 125 I]-labeled proteins in arterial tissue using Kodak NTB-2 nuclear emulsion. A precise linear relationship between measured silver grain density and isotope concentration was obtained with uniformly labeled standard sources composed of epoxy-embedded gelatin containing glutaraldehyde-fixed [ 125 I]-albumin. For up to 308-day exposures of 1 micron-thick tissue sections, background grain densities ranged from about two to eight grains/1000 micron 2, and the technique was sensitive to as little as about one grain/1000 micron 2 above background, which correspond to a radioactivity concentration of about 2 x 10(4) cpm/ml. A detailed statistical analysis of variability was performed and the sum of all sources of variation quantified. The half distance for spatial resolution was 1.7 micron. Both visual and automated techniques were employed for quantitative grain density analysis. The method was illustrated by measurement of in vivo transmural [ 125 I]-low-density lipoprotein [( 125 I]-LDL) concentration profiles in de-endothelialized rabbit thoracic aortic wall

  12. Behaviour of 125I added to limnocorrals in two Canadian Shield lakes of differing trophic states

    International Nuclear Information System (INIS)

    Bird, Glen A.; Motycka, M.; Rosentreter, J.; Schwartz, W.J.; Vilks, P.

    1995-01-01

    The main objectives of our investigation were to determine the loss rate of iodine from water to sediment and to gain a better understanding of the behaviour of iodine in Shield lakes. Iodine-125 and tritium ( 3 HHO) were added to the epilimnion of limnocorrals (enclosures) in mesotrophic Lake 226 and eutrophic Lake 227, Experimental Lakes Area, northwestern Ontario. The change in the 125 I/ 3 H ratio was used to measure the loss of 125 I from the epilimnion. Loss rate coefficients, (k), ranged from -0.0017 to -0.0074 day -1 . The 125 I was found primarily in the d ) had geometric means (/xgeometric standard deviations) of 2526/x62.1 l·kg -1 dry weight (dw) for suspended sediment, 1362 ± 2.9 l·kg -1 dw for particles in sediment traps and 132/x6 l·kg -1 dw for bottom sediment. Concentrations in fish ranged from = 8 to 184 Bq·g -1 dw, whereas concentration factors from water to fish ranged from 20 to 390 l·kg -1 dw. Iodine behaves as a conservative element in Shield lakes, although it is available for uptake by biota. The persistence of 125 I in water and its accumulation by fish emphasizes the potential importance of these pathways in the radiological dose to humans

  13. Determination of bone density via /sup 125/I-densitometry in idiophathic scoliosis

    Energy Technology Data Exchange (ETDEWEB)

    Matzen, K.A.; Milachowski, K.A.; Weinberger, N.; Rohloff, R.

    1984-12-01

    The aim of the present study was to find out whether idiopathic scoliosis is associated with a general reduction of the calcium salt content of the bones. The study was conducted in a scoliosis patient group of 48 individuals, using /sup 125/I densitometry.

  14. Distribution of /sup 125/I-thyroxine in different organs and tissues of dietically obese rats

    Energy Technology Data Exchange (ETDEWEB)

    Hartmann, K.; Voss, C.; Huebner, G. (Ernst-Moritz-Arndt-Universitaet, Greifswald (German Democratic Republic)); Weber, A. (Ernst-Moritz-Arndt-Universitaet, Greifswald (German Democratic Republic). Radiologische Klinik)

    1985-04-01

    The distribution of /sup 125/I-thyroxine (% dose/g tissue; tissue/plasma radioactivity ratio) was investigated in different tissues of 28-week-old obese Wistar rats. Obesity was induced by high-fat diet (HFD) and confirmed by carcass analysis; in heavy obese animals the relative and absolute fat content is increased twofold and threefold, respectively, compared to control rats fed on a low-fat diet (LFD). Heavy HFD rats exhibit diminished /sup 125/I-T/sub 4/ distribution in the 'slow pool' (fat tissue, muscle) and unchanged values in the 'fast pool' (liver, kidneys) in comparison with LFD rats with low body weight. The differences in distribution presented here are not caused by the diet per se, but they are the consequence of the obesity of the animal, because no differences in the /sup 125/I-T/sub 4/ distribution were found in the /sup 125/I-T/sub 4/ between HFD and LFD rats with relatively equal body weight and body composition. The reduced T/sub 4/ distribution in the fat tissue of obese rats is discussed in connection with possibly decreased lipolysis in this tissue and possible causal participation in the beginning of obesity.

  15. R.I.S.-125 {sup 125}I air monitor system

    Energy Technology Data Exchange (ETDEWEB)

    Belaish, I; Levinson, S; German, U; Pelled, O; Laichter, Y; Wangrovitz, U; Tirosh, D; Barak, D [Israel Atomic Energy Commission, Beersheba (Israel). Nuclear Research Center-Negev

    1996-12-01

    We have developed at NRCN a prototype of a continuous K-Ray air monitoring (CAM) system called `R.1.S.-125` (Radioactive Isotope Sampler for {sup 125}I). The system. was checked according to ANSI N42.17B -1989 (authors).

  16. Effects of age and sex on 125I-β-CIT binding to DAT

    International Nuclear Information System (INIS)

    Liu Xingdang; Lin Xiangtong

    2000-01-01

    Objective: To investigate effects of age and sex on 125 I-β-CIT binding to dopamine transporter (DAT). Methods: Detection of the differences in 125 I-β-CIT binding kinetics in vivo between 6 week and 6 month old KM mice, and the differences of in vivo binding between female and male, and between 3 month and 12 month old SD rats.The animals were sacrificed 2 h after injection. Results: Uptake of 125 I-β-CIT in the striatum, frontal cortex, parietal cortex, temporal cortex, occipital cortex, hippocampus, brain stem and whole brain in 6 week old mice was higher than that in 6 month old mice, and similar uptake pattern happened in between 3 month old and in 12 month old SD rats. In 12 months old SD rats, female rats had higher uptake in the striatum than male rats did. Conclusions: Young mice and rats have a higher uptake of 125 I-β-CIT in the striatum than aged ones and female rats have a higher uptake than male ones do. This result indicates that the density of DAT in rat or mouse striatum may be reduced with aging

  17. Validation of 125I-hCG as a marker for elimination of hCG and stability of 125I-hCG after in vivo injection in humans

    OpenAIRE

    Christensen, T B; Marqversen, J; Engbaek, F; Berger, P; Bacher, T; Maase, H von der

    1999-01-01

    We have recently introduced 125I-hCG as an elimination marker in patients with human chorionic gonadotrophin (hCG) producing testicular cancer. 125I-hCG is a well-known reagent in clinical biochemistry and is used extensively in hCG assays. Previous studies have shown that the iodination process leaves the hCG molecule mainly intact. The iodination, purification and stability of 125I-hCG tracer are described. The aim of the present study was to determine whether or not 125I is associated with...

  18. Experimental evaluation of an online gamma-camera imaging of permanent seed implantation (OGIPSI) prototype for partial breast irradiation

    International Nuclear Information System (INIS)

    Ravi, Ananth; Caldwell, Curtis B.; Pignol, Jean-Philippe

    2008-01-01

    Previously, our team used Monte Carlo simulation to demonstrate that a gamma camera could potentially be used as an online image guidance device to visualize seeds during permanent breast seed implant procedures. This could allow for intraoperative correction if seeds have been misplaced. The objective of this study is to describe an experimental evaluation of an online gamma-camera imaging of permanent seed implantation (OGIPSI) prototype. The OGIPSI device is intended to be able to detect a seed misplacement of 5 mm or more within an imaging time of 2 min or less. The device was constructed by fitting a custom built brass collimator (16 mm height, 0.65 mm hole pitch, 0.15 mm septal thickness) on a 64 pixel linear array CZT detector (eValuator-2000, eV Products, Saxonburg, PA). Two-dimensional projection images of seed distributions were acquired by the use of a digitally controlled translation stage. Spatial resolution and noise characteristics of the detector were measured. The ability and time needed for the OGIPSI device to image the seeds and to detect cold spots was tested using an anthropomorphic breast phantom. Mimicking a real treatment plan, a total of 52 103 Pd seeds of 65.8 MBq each were placed on three different layers at appropriate depths within the phantom. The seeds were reliably detected within 30 s with a median error in localization of 1 mm. In conclusion, an OGIPSI device can potentially be used for image guidance of permanent brachytherapy applications in the breast and, possibly, other sites

  19. Studies on the distribution of 125I-labelled Hemorrhagic toxin from agkistrodon acutus (125I-AaT) in rabbits and its pharmacokinetic characters

    International Nuclear Information System (INIS)

    Huang Yuchu; Jiang Bo; Wang Yuzheng; Xu Xun

    1988-01-01

    125 I-AaT, prepared by oxidant-chloroamine T from the related venom of Agkistrodon Acutus, is given to a rabbit by intravenous injection, and then, the distribution of the toxin in the rabbit and its pharmacokinetic characters have been studied.The rabbit is killed five hours after the injection, and the radioactivity in each tissue calculated. The result indicates that the blood-brain barrier exist in the body, and large quantity of by-products of 125 I-AaT metabolism is eliminated from urine by the kidney. For pharmacokinetics, the computer simulated curve demonstrates that the result conforms to the Two Compartment Model. The fast component half-life T 1/2α is 3.15 mins. , the slow component half-life T 1/2β is 165 mins. , and the biological half-life T 1/2 is 75.2 mins.V d33 , V t and V e have been analyzed, and the author thinks preliminarily that there must have been a corresponding receptor to the toxin in the body

  20. Development of a high specific activity radioligand, 125I-LSD, and its application to the study of serotonin receptors

    International Nuclear Information System (INIS)

    Kadan, M.J.

    1987-01-01

    125 I-Labeled receptor ligands can be synthesized with specific activities exceeding 2000 Ci/mmol, making them nearly 70-fold more sensitive in receptor site assays than (mono) tritiated ligands. We have synthesized and characterized 125 I-lysergic acid diethylamide ( 125 I-LSD), the first radioiodinated ligand for serotonin receptor studies. The introduction of 125 I at the 2 position of LSD increased both the affinity and selectivity of this compound for serotonin 5-HT 2 receptors in rat cortex. The high specific activity of 125 I-LSD and its high ratio of specific to nonspecific binding make this ligand especially useful for autoradiographic studies of serotonin receptor distribution. We have found that 125 I-LSD binds with high affinity to a class of serotonin receptors in the CNS of the marine mollusk Aplysia californica

  1. Assessment of I-125 seed implant accuracy when using the live-planning technique for low dose rate prostate brachytherapy

    Directory of Open Access Journals (Sweden)

    Moorrees Joshua

    2012-11-01

    Full Text Available Abstract Background Low risk prostate cancers are commonly treated with low dose rate (LDR brachytherapy involving I-125 seeds. The implementation of a ‘live-planning’ technique at the Royal Adelaide Hospital (RAH in 2007 enabled the completion of the whole procedure (i.e. scanning, planning and implant in one sitting. ‘Live-planning’ has the advantage of a more reliable delivery of the planned treatment compared to the ‘traditional pre-plan’ technique (where patient is scanned and planned in the weeks prior to implant. During live planning, the actual implanted needle positions are updated real-time on the treatment planning system and the dosimetry is automatically recalculated. The aim of this investigation was to assess the differences and clinical relevance between the planned dosimetry and the updated real-time implant dosimetry. Methods A number of 162 patients were included in this dosimetric study. A paired t-test was performed on the D90, V100, V150 and V200 target parameters and the differences between the planned and implanted dose distributions were analysed. Similarly, dosimetric differences for the organs at risk (OAR were also evaluated. Results Small differences between the primary dosimetric parameters for the target were found. Still, the incidence of hotspots was increased with approximately 20% for V200. Statistically significant increases were observed in the doses delivered to the OAR between the planned and implanted data; however, these increases were consistently below 3% thus probably without clinical consequences. Conclusions The current study assessed the accuracy of prostate implants with I-125 seeds when compared to initial plans. The results confirmed the precision of the implant technique which RAH has in place. Nevertheless, geographical misses, anatomical restrictions and needle displacements during implant can have repercussions for centres without live-planning option if dosimetric changes are not

  2. Production of 125I from amorphous films of Si doped with 124Xe and evaluation of its potential use in brachytherapy

    International Nuclear Information System (INIS)

    Leal, Alexandre S.; Viana, Gustavo A.

    2015-01-01

    This work describes the simulation of a new material that can be used in the brachytherapy treatment. The material consists of xenon-incorporated amorphous silicon (Xe@a-Si). The irradiated 124 Xe atoms of the samples are converted into 125 Xe, according to the reaction: 124 Xe (n,γ) 125 Xe that, in turn, decays to the radioisotope 125 I. A set of simulations performed using the MCNP5 code, shows that, in principle, the material proposed can be used in the seed of brachytherapy in the clinical treatment. (author)

  3. SU-E-T-12: A Comparative Dosimetric Study of Pre and Post Prostate Iodine-125 Permanent Seed Implants

    Energy Technology Data Exchange (ETDEWEB)

    Liu, X; Rahimian, J; Goy, B; Cosmatos, H; Qian, Y [Kaiser Permanente, Los Angeles, CA (United States)

    2015-06-15

    Purpose: Post-implant dosimetry has become the gold standard for prostate implant evaluation. The goal of this research is to compare the dosimetry between pre-plan and post-plan in permanent prostate seed implant brachytherapy. Methods: A retrospective study of 91 patients treated with Iodine-125 prostate seed implant between year 2012∼2014 were performed. All plans were created using a VariSeed 8.0 planning system. Pre-plan ultrasound images were acquired using 0.5 cm slice thickness. Post-plan CT images acquired about 1–4 weeks after implant, fused with the preplan ultrasound images. The prostate and urethra contours were generated using the fusion of ultrasound and CT images. Iodine-125 seed source activities varied between 0.382 to 0.414 mCi per seed. The loading patterns varied slightly between patients depending on the prostate size. Statistical analysis of pre and post plans for prostate and urethra volumes, V100%, V150% and D90, and urethra D10 were performed and reported. Results: The pre and post implant average prostate size was 36.90cc vs. 38.58cc; V100% was 98.33% vs. 96.89%; V150% was 47.09% vs. 56.95%; D90 was 116.35Gy vs. 116.12Gy, urethra volume was 1.72cc vs. 1.85cc, urethra D10% was 122.0% vs. 135.35%, respectively. There was no statistically significant difference between the pre and post-plan values for D90(p-value=0.43). However, there are significant differences between other parameters most likely due to post surgical edema; prostate size (p-value= 0.00015); V100% (p-value=3.7803E-07); V150% (p-value=1.49E-09); urethra volume (p-value= 2.77E-06); Urethra D10 (p-value=7.37E-11). Conclusion: The post-plan dosimetry using CT image set showed similar D90 dose coverage to the pre-plan using the ultrasound image dataset. The study showed that our prostate seed implants have consistently delivered adequate therapeutic dose to the prostate while sparing urethra. Future studies to correlate dose versus biochemical response using patients’ PSA

  4. Cytotoxic effects of 125I-labeled PBZr ligand PK 11195 in prostatic tumor cells: therapeutic implications

    International Nuclear Information System (INIS)

    Alenfall, J.; Kant, R.; Batra, S.

    1998-01-01

    The effect of [ 125 I]PK 11195 was examined in human prostatic tumor cells (DU 145) in culture and compared with Na[ 125 I] and non-radioactive PK 11195. [ 125 I]PK 11195 was clearly cytocidal. The data for dose-related cell survival with [ 125 I]PK 11195 showed a linear relationship. Na[ 125 I] or non-labeled PK 11195 at similar concentrations did not lead to any cell killing. The uptake of [ 125 I]PK 11195 and [ 3 H]PK 11195 in cells was very similar. Fragmentation of DNA measured by agarose gel electrophoresis showed that exposure of DU 145 cells to [ 125 I]PK 11195 for 1, 4 or 24 h caused no fragmentation. These results indicate that nuclear DNA is not the prime binding site for [ 125 I]PK 11195, which is consistent with the presence of specific peripheral benzodiazepine receptors (PBZr) in the mitochondria. The cell killing effect of [ 125 I]PK 11195 suggests the use of PBZr ligand for radiotherapy

  5. Anti-tumor effects of Egr-IFN γ gene therapy combined with 125I-UdR radionuclide therapy

    International Nuclear Information System (INIS)

    Zhao Jingguo; Ni Yanjun; Song Xiangfu; Li Yanyi; Yang Wei; Sun Ting; Ma Qingjie; Gao Fengtong

    2008-01-01

    Objective: To explore the anti-tumor effects of Egr-IFNγ gene therapy combined with 125 I-UdR radionuclide therapy in mice bearing H22 hepatocarcinoma and its mechanism. Methods: The recombinant plasmid pcDNAEgr-IFNγ mixed with liposome was injected into tumor. 48 h later, 370 kBq 125 I-UdR was injected into tumor. The tumor growth rates at different times were observed. After 3 d gene-radionuclide therapy, the concentration of IFNγ in cytoplasm of H22 cells and cytotoxic activities of splenic CTL of the mice in different groups were examined. Results: The tumor growth rates of pcDNAEgr-IFNγ + 125 I-UdR group were obviously lower than those of control group, 125 I-UdR group and pcDNAEgr-1 + 125 I-UdR group 6-15 d after gene-radionuclide therapy. IFNγ protein was found in cytoplasm of H22 cells in pcDNAEgr-IFNγ + 125 I-UdR group after 3 d gene-radionuclide therapy. Cytotoxic activity of splenic CTL in pcDNAEgr-IFNγ + 125 I-UdR group was significantly higher than that in the other groups (P 125 I-UdR radionuclide therapy are better than those of 125 I-UdR therapy. (authors)

  6. Identification of beta 2-adrenoceptors on guinea pig alveolar macrophages using (-)-3-[125I]iodocyanopindolol

    International Nuclear Information System (INIS)

    Leurs, R.; Beusenberg, F.D.; Bast, A.; Van Amsterdam, J.G.; Timmerman, H.

    1990-01-01

    The beta-adrenoceptor antagonist (-)-3-[ 125 I]iodocyanopindolol ([ 125 I]ICYP) binds with high affinity and in saturable way to membranes of guinea pig alveolar macrophages. The equilibrium dissociation constant for [ 125 I]ICYP is 24.3 +/- 1.2 pM, and the number of binding sites is 166.3 +/- 13.7 fmol/mg protein (N = 4, +/- SEM). Displacement studies with selective antagonists showed that [ 125 I]ICYP labels beta 2-adrenoceptors on guinea pig alveolar macrophages

  7. Fragmentation of Nimotuzumab for Preparation of 125I-F(ab’2-Nimotuzumab as a Precursor for Preparing 125I-F(ab’2-Nimotuzumab-NLS Radiopharmaceutical for Cancer Therapy

    Directory of Open Access Journals (Sweden)

    R.D. Haryuni

    2014-04-01

    Full Text Available Nimotuzumab is an anticancer agent which belongs to the inhibitor group of Epidermal Growth Factor Receptor (EGFR. This monoclonal antibody has a relatively high molecular weight which makes slow penetration on tumor cell, as concequence, it is less attractive in imaging kinetics, and potentially elicits antibodies respons. Therefore in this study nimotuzumab was fragmented to form bivalent antibody [F(ab’2] and then labeled with 125I to form 125I-F(ab’2-nimotuzumab which can be used further as a precursor for preparing 125I-F(ab’2-nimotuzumab-NLS (NLS = nuclear localizing sequences radiopharmaceutical for radioimmunotherapy. The aims of this study were to obtain characteristics of 125I-F(ab’2-nimotuzumab by comparing with the 125I labeled-intact nimotuzumab (125I-nimotuzumab. This study was initiated by purifying nimotuzumab by mean of dialysis. The purified nimotuzumab was then fragmented by using pepsin. The F(ab'2-nimotuzumab formed was then purified from its by-products which formed in fragmentation process by using a PD-10 column (consisted Sephadex G25. The intact nimotuzumab and its F(ab’2 fragment were then labeled with the 125I to form 125I-nimotuzumab and 125I-F(ab’2-nimotuzumab. The radiochemical purity are 98.27 % and 93.24 % ,respectively. Stability test results show that, both of 125I-nimotuzumab and 125I-F(ab’2-nimotuzumab more stable at 4 °C than at room temperature storage and 37 °C

  8. Fragmentation of Nimotuzumab for Preparation of 125I-F(ab’)2-Nimotuzumab as a Precursor for Preparing 125I-F(ab’)2-Nimotuzumab-NLS Radiopharmaceutical for Cancer Therapy

    International Nuclear Information System (INIS)

    Haryuni, R.D.; Bahtiar, A.; Soenarjo, S.; Harahap, Y.; Mutalib, A.; Ramli, M.; Hermanto, S.; Ardiyatno, C.N.; Susilo, V.Y.; Haffid, D.

    2014-01-01

    Nimotuzumab is an anticancer agent which belongs to the inhibitor group of Epidermal Growth Factor Receptor (EGFR). This monoclonal antibody has a relatively high molecular weight which slows penetration on tumor cells, making it less attractive in imaging kinetics and potentially elicits antibodies responses. Therefore, in this study nimotuzumab was fragmented to form a bivalent antibody [F(ab’) 2 ] and then labeled with 125 I to form 125 I-F(ab’) 2 -nimotuzumab which can be used further as a precursor for preparing 125 I-F(ab’) 2 -nimotuzumab-NLS (NLS = nuclear localization sequence) radiopharmaceutical for radioimmunotherapy. The aims of this study was to obtain characteristics of 125 I-F(ab’) 2 -nimotuzumab by comparing with the 125 I labeled-intact nimotuzumab ( 125 I-nimotuzumab). This study was initiated by purifying nimotuzumab by mean of dialysis. The purified nimotuzumab was then fragmented by using pepsin. The F(ab') 2 -nimotuzumab formed was then purified from its by-products which formed in fragmentation process by using a PD-10 column (consisted Sephadex G25). The intact nimotuzumab and its F(ab’)2 fragment were then labeled with the 125 I to form 125 I-nimotuzumab and 125 I-F(ab’) 2 -nimotuzumab. The radiochemical purity are 98.27 % and 93.24 %, respectively. Stability test results show that, both 125 I-nimotuzumab and 125 I-F(ab’) 2 -nimotuzumab are more stable at 4 °C than at room temperature storage and 37 °C. (author)

  9. Poster — Thur Eve — 77: Implanted Brachythearpy Seed Movement due to Transrectal Ultrasound Probe-Induced Prostate Deformation

    International Nuclear Information System (INIS)

    Liu, D; Usmani, N; Sloboda, R; Meyer, T; Husain, S; Angyalfi, S; Kay, I

    2014-01-01

    The study investigated the movement of implanted brachytherapy seeds upon transrectal US probe removal, providing insight into the underlying prostate deformation and an estimate of the impact on prostate dosimetry. Implanted seed distributions, one obtained with the prostate under probe compression and another with the probe removed, were reconstructed using C-arm fluoroscopy imaging. The prostate, delineated on ultrasound images, was registered to the fluoroscopy images using seeds and needle tracks identified on ultrasound. A deformation tensor and shearing model was developed to correlate probe-induced seed movement with position. Changes in prostate TG-43 dosimetry were calculated. The model was used to infer the underlying prostate deformation and to estimate the location of the prostate surface in the absence of probe compression. Seed movement patterns upon probe removal reflected elastic decompression, lateral shearing, and rectal bending. Elastic decompression was characterized by expansion in the anterior-posterior direction and contraction in the superior-inferior and lateral directions. Lateral shearing resulted in large anterior movement for extra-prostatic seeds in the lateral peripheral region. Whole prostate D90 increased up to 8 Gy, mainly due to the small but systematic seed movement associated with elastic decompression. For selected patients, lateral shearing movement increased prostate D90 by 4 Gy, due to increased dose coverage in the anterior-lateral region at the expense of the posterior-lateral region. The effect of shearing movement on whole prostate D90 was small compared to elastic decompression due to the subset of peripheral seeds involved, but is expected to have greater consequences for local dose coverage

  10. Study on the thyroid function of thoroughbred females in varying stages of pregnancy using 'in vitro' tests /sup 125/I-T/sub 3/ and /sup 125/I-T/sub 4/

    Energy Technology Data Exchange (ETDEWEB)

    de Martin, B W [Sao Paulo Univ. (Brazil). Faculdade de Medicina Veterinaria e Zootecnia

    1975-01-01

    A study is made on the thyroid function of thoroughbred female equines, aged between five through twelve years, in varying stages of pregnancy, using 'in vitro' tests /sup 125/I.T/sub 3/ and /sup 125/I-T/sub 4/.

  11. Postimplantation Analysis Enables Improvement of Dose-Volume Histograms and Reduction of Toxicity for Permanent Seed Implantation

    International Nuclear Information System (INIS)

    Wust, Peter; Postrach, Johanna; Kahmann, Frank; Henkel, Thomas; Graf, Reinhold; Cho, Chie Hee; Budach, Volker; Boehmer, Dirk

    2008-01-01

    Purpose: To demonstrate how postimplantation analysis is useful for improving permanent seed implantation and reducing toxicity. Patients and Methods: We evaluated 197 questionnaires completed by patients after permanent seed implantation (monotherapy between 1999 and 2003). For 70% of these patients, a computed tomography was available to perform postimplantation analysis. The index doses and volumes of the dose-volume histograms (DVHs) were determined and categorized with respect to the date of implantation. Differences in symptom scores relative to pretherapeutic status were analyzed with regard to follow-up times and DVH descriptors. Acute and subacute toxicities in a control group of 117 patients from an earlier study (June 1999 to September 2001) by Wust et al. (2004) were compared with a matched subgroup from this study equaling 110 patients treated between October 2001 and August 2003. Results: Improved performance, identifying a characteristic time dependency of DVH parameters (after implantation) and toxicity scores, was demonstrated. Although coverage (volume covered by 100% of the prescription dose of the prostate) increased slightly, high-dose regions decreased with the growing experience of the users. Improvement in the DVH and a reduction of toxicities were found in the patient group implanted in the later period. A decline in symptoms with follow-up time counteracts this gain of experience and must be considered. Urinary and sexual discomfort was enhanced by dose heterogeneities (e.g., dose covering 10% of the prostate volume, volume covered by 200% of prescription dose). In contrast, rectal toxicities correlated with exposed rectal volumes, especially the rectal volume covered by 100% of the prescription dose. Conclusion: The typical side effects occurring after permanent seed implantation can be reduced by improving the dose distributions. An improvement in dose distributions and a reduction of toxicities were identified with elapsed time between

  12. Enzymatic iodination of salivary proteins by the 125I-lactoperoxidase system

    International Nuclear Information System (INIS)

    Tenovuo, J.; Sarimo, S.S.

    1977-01-01

    Purified milk lactoperoxidase and endogenous human salivary peroxidase were used to label the proteins of whole mouth saliva with [ 125 I]iodide. The proteins were then analyzed by isoelectric focusing or they were subjected to one-dimensional polyacrylamide gel electrophoresis at pH 8.4. The radioactivity of the resolved protein fractions was determined. There were three to four major and four to five minor areas of radioactivity which were carried together with more or less distinctive fractions. Amylase and albumin were shown to be the most effective in binding [ 125 I]iodide. No significant differences were observed in the iodination patterns of salivary proteins iodinated in the presence of endogenous saliva peroxidase and those iodinated in the presence of added milk lactoperoxidase. Hydrogen peroxide was necessary for iodination to take place. The significance of iodoproteins and the role of salivary peroxidases in the nonthyroidal metabolism of iodine are discussed. (author)

  13. A simple method for the preparation of 123I and 125I labeled iodobenzodiazepines

    International Nuclear Information System (INIS)

    McBride, B.J.; Baldwin, R.M.; Kerr, J.M.; Jiannlong Wu

    1991-01-01

    The tributyltin derivative of the benzodiazepine antagonist ethyl 7-iodo-5,6-dihydro-5-methyl-6-oxo-4H-imidazo[1,5-a][1,4]benzodiazepine-3-carboxylate (Ro 16-0154) was synthesized by a one-step Pd catalyzed reaction between bistributyltin and Ro 16-0154. Electrophilic iodination of the tributyltin compound with no-carrier-added 125 I and 123 I gave a 50-70% radiochemical yield of a greater than 98% radiochemically pure Ro 16-0154. The specific activity of [ 123 I]Ro 16-0154 and [ 125 I]Ro 16-0154 was 180,000 and 1700 Ci/mmol, respectively, but the effective specific activity was 6900 and 300 Ci/mmol due to the presence of benzodiazepine impurities which have similar receptor binding properties. (author)

  14. Preparation of [123I]- and [125I]epidepride: a dopamine D-2 receptor antagonist radioligand

    International Nuclear Information System (INIS)

    Clanton, J.A.; Schmidt, D.E.; Ansari, M.S.; Manning, R.G.; Kessler, R.M.; Paulis, T. de; Vanderbilt Univ., Nashville, TN; Baldwin, R.M.

    1991-01-01

    (S)-(-)-N-[(1-ethyl-2-pyrrolidinyl)methyl]-5-[ 123 I] iodo-2,3-dimethoxybenzamide (TDP 517) (proposed generic name, [ 123 I]epidepride) is the iodine-123 substituted analogue of isoremoxipride (FLB 457), both of which are very potent dopamine D-2 antagonists (epidepride K D 0.024 nM). [ 123 I] Epidepride was radioiodinated in 60-70% radiochemical yields in 35 min from the corresponding 5-(tributyltin) derivative using Na 123 I with a specific radioactivity of 3000 Ci/mmol, and oxidized in situ with chloramine-T. The aryltin precursor was prepared from non-labelled epidepride by palladium-catalyzed stannylation using bis(tri-n-butyltin) in triethylamine. Alternatively, using no carrier-added Na 125 I as the radioisotope, [ 125 I] epidepride at 2000 Ci/mmol specific radioactivity was prepared in 86% radiochemical yield and 99% radiochemical purity after purification by reverse phase HPLC in ethanolic phosphate buffer. (author)

  15. Synthesis and biological evaluation of 125I-erythropoietin as a potential radiopharmaceutical agent for tumours

    International Nuclear Information System (INIS)

    Clemente, Goncalo dos Santos; Duarte, Vera Lucia Serra

    2011-01-01

    Erythropoietin (EPO) is a glycoprotein hormone responsible for regulating erythropoiesis. Expression of EPO and EPO receptors (EPOr) has recently been demonstrated in some neoplastic cell lines and tumours, suggesting a potential new target for therapy. In this work, EPO was labeled with iodine-125 using the lactoperoxidase method, known to prevent damage to protein during radioiodination, and labeling conditions were optimized. In vitro stability studies have shown that 125 I-EPO is radiochemically stable for 20 days after radiolabeling. In vitro cell binding studies have demonstrated very low binding ( 125 I-EPO. In mice with induced melanoma, only a residual fixation in the tumour was evident. Further studies are warranted on other tumoral cell lines to better understand the binding process and internalization into cells. Studies on EPO labeled with carbon-11 could be valuable, since there is a greater chance of preserving the biological activity of the protein using this method. (author)

  16. Application of different 125I tracers in radioimmunoassays of estradiol-17β

    International Nuclear Information System (INIS)

    Bienert, R.; Flentje, H.; Herzmann, H.; Akademie der Wissenschaften der DDR, Leipzig. Zentralinstitut fuer Isotopen- und Strahlenforschung)

    1984-01-01

    Some different 125 I-labelled estradiol tracers were produced by direct radioiodizing of estradiol and also of the histamine and tyramine conjugates of estradiol-3-carboxymethylether (E 2 -3-CM) by means of the chloramine-T method. The linkage properties of these tracers were investigated in relation to the 3 H-labelled estradiol opposite to the antisera, which were produced against the cow serum albumin (RSA) conjugates of E 2 -3-CM and estradiol-6-carboxymethyloxime (E 2 -6-CMO). As suitable system for the radioimmunological estradiol determination could be revealed 4- 125 I-iodine estradiol in connection with one antiserum in each case of the radioligand antiserum combinations against E 2 -3-CM-RSA- and E 2 -6-CMO-RSA-conjugate. The double antibody method is used for separation in optimized RIA systems. The first and the second antibody reaction take place simultaneously. (author)

  17. Pitfalls of radioisotope diagnosis of deep venous thromboses with /sup 125/I-fibrinogen in traumatology

    Energy Technology Data Exchange (ETDEWEB)

    Novak, K.; Pestal, M. (Vyzkumny Ustav Traumatologicky, Brno (Czechoslovakia))

    1984-05-25

    Experience is described with the examination of deep venous thromboses of the lower extremities using /sup 125/I-fibrinogen. Intravenously administered labelled fibrinogen is taken up into the forming thrombus which may then be detected. Experience is presented with preparations of various makes. It was proved that in injured patients the biological half-life of /sup 125/I-fibrinogen is reduced to 50 hrs and less as against the standard half-life of 96.2 hrs. This is caused by fibrinogen losses owing to the injury, increased intensity of metabolic processes and the quality of the preparation being used. Injured patients should be examined using a highest quality preparation without denaturation damage to the labelled protein.

  18. Pitfalls of radioisotope diagnosis of deep venous thromboses with 125I-fibrinogen in traumatology

    International Nuclear Information System (INIS)

    Novak, K.; Pestal, M.

    1984-01-01

    Experience is described with the examination of deep venous thromboses of the lower extremities using 125 I-fibrinogen. Intravenously administered labelled fibrinogen is taken up into the forming thrombus which may then be detected. Experience is presented with preparations of various makes. It was proved that in injured patients the biological half-life of 125 I-fibrinogen is reduced to 50 hrs and less as against the standard half-life of 96.2 hrs. This is caused by fibrinogen losses owing to the injury, increased intensity of metabolic processes and the quality of the preparation being used. Injured patients should be examined using a highest quality preparation without denaturation damage to the labelled protein. (Ha)

  19. Behaviour of homologous 125I fibrinogen after thrombin and ancrod infusion in rabbits

    International Nuclear Information System (INIS)

    Setter, R.

    1977-01-01

    The behaviour of radioactively labelled fibrinogen after infusion of thrombin or ancrod is investigated. Common factors and differences in the behaviour of fibrinogen after infusion of these two enzymes, which act proteolytically on the fibrinogen, are dealt with. Rabbits received an i.v. injection of homologous 125 I-fibrinogen 3 days before ancrod or thrombin infusion. On the day of the experiments, one group of animals received an ancrod infusion (1.5 U/kg body weight for 30 minutes), the other a thrombin infusion (600 U/kg body weight for 60 minutes). Intravenous ancrod and thrombin infusions lowered the fibrinogen level to 30% or 50% of the initial value due to intravascular coagulation. About 50% of the 125 I fibrinogen was transformed after ancrod exposure into a non-coagulating fraction of fibrinogen derivatives which produces no fibrinolytic decomposition products. (orig./AJ) [de

  20. Amino acid tolerance test using L-β-phenylalanine-125I

    International Nuclear Information System (INIS)

    Hafiez, A.A.; Megahed, Y.M.; Ismail, A.A.; Abdel-Wahab, M.F.; Khater, R.A.

    1978-01-01

    An amino acid tolerance test is described. L-β-phenylalanine- 125 I was used as representative of L-amino acids. The change in radioactivity of the blood after giving a test dose of tagged L-β-phenylalanine was also investigated. L-β-phenylalanine- 125 I tolerance curves were found to be irreproducible when the test dose was given without a carrier. The addition of 2.5 g untagged phenylalanine as a carrier to the test dose allowed a reproducible and precise type of tolerance curves. Metformin in a dose of 0.5 g t.d.s. for three days induced an inhibitory effect on amino acid absorption in normal persons. (author)

  1. Synthesis and binding characteristics of N-(1-naphthyl)-N'-(3-[{sup 125}I]-iodophenyl)-N'-methylguanidine ([{sup 125}I]-CNS 1261): a potential SPECT agent for imaging NMDA receptor activation

    Energy Technology Data Exchange (ETDEWEB)

    Owens, Jonathan E-mail: j.owens@clinmed.gla.ac.uk; Tebbutt, Andrew A.; McGregor, Ailsa L.; Kodama, K.; Magar, Sharad S.; Perlman, Michael E.; Robins, David J.; Durant, Graham J.; McCulloch, James

    2000-06-01

    N-(1-Naphthyl)-N'-(3-[{sup 125}I]-iodophenyl)-N'-methylguanidine ([{sup 125}I]-CNS 1261) was synthesized as a potential radioligand to image N-methyl-D-aspartate (NMDA) receptor activation. [{sup 125}I]-CNS 1261 was prepared by radioiodination of N-(1-naphthyl)-N'-(3-tributylstannylphenyl)-N'-methylguanidine using Na{sup 125}I and peracetic acid. [{sup 125}I]-CNS 1261 uptake in vivo reflected NMDA receptor distribution in normal rat brain, whereas in ischemic rat brain, uptake was markedly increased in areas of NMDA receptor activation. Radiolabeled CNS 1261 appears to be a good candidate for further development as a single photon emission computed tomography tracer in the investigation of NMDA receptor activation in cerebral ischemia.

  2. Synthesis and binding characteristics of N-(1-naphthyl)-N'-(3-[125I]-iodophenyl)-N'-methylguanidine ([125I]-CNS 1261): a potential SPECT agent for imaging NMDA receptor activation

    International Nuclear Information System (INIS)

    Owens, Jonathan; Tebbutt, Andrew A.; McGregor, Ailsa L.; Kodama, K.; Magar, Sharad S.; Perlman, Michael E.; Robins, David J.; Durant, Graham J.; McCulloch, James

    2000-01-01

    N-(1-Naphthyl)-N'-(3-[ 125 I]-iodophenyl)-N'-methylguanidine ([ 125 I]-CNS 1261) was synthesized as a potential radioligand to image N-methyl-D-aspartate (NMDA) receptor activation. [ 125 I]-CNS 1261 was prepared by radioiodination of N-(1-naphthyl)-N'-(3-tributylstannylphenyl)-N'-methylguanidine using Na 125 I and peracetic acid. [ 125 I]-CNS 1261 uptake in vivo reflected NMDA receptor distribution in normal rat brain, whereas in ischemic rat brain, uptake was markedly increased in areas of NMDA receptor activation. Radiolabeled CNS 1261 appears to be a good candidate for further development as a single photon emission computed tomography tracer in the investigation of NMDA receptor activation in cerebral ischemia

  3. Localization of 125I-insulin binding sites in the rat hypothalamus by quantitative autoradiography

    International Nuclear Information System (INIS)

    Corp, E.S.; Woods, S.C.; Figlewicz, D.P.; Porte, D. Jr.; Baskin, D.G.; Dorsa, D.M.

    1986-01-01

    In vitro autoradiography and computer video densitometry were used to localize and quantify binding of 125 I-insulin in the hypothalamus of the rat brain. Highest specific binding was found in the arculate, dorsomedial, suprachiasmatic, paraventricular and periventricular regions. Significantly lower binding was present in the ventromedial nucleus and median eminence. The results are consistent with the hypothesis that insulin modulates the neural regulation of feeding by acting at sites in the hypothalamus. (author)

  4. Compartment analysis of 125I-labelled albumin washout from coronary vessels of isolated perfused hearts

    International Nuclear Information System (INIS)

    Cheng Eap Ng; Seh-Hoon Song

    1978-01-01

    Albumin labelled with 125 I was used as a tracer to investigate the washout kinetics of plasma from the coronary circulation of isolated perfused feline hearts. Compartmentalization with experimental results showed at least two compartments. The model was compared with a three-compartment model found previously for red blood cells. The results indicate that there is a separation of plasma and RBC in the coronary microcirculation. (author)

  5. Specific absorption in vivo of the [125 I] insulin by the Chrysemys dorbigni turtle thyroid

    International Nuclear Information System (INIS)

    Coutinho, Ligia Maria Barbosa.

    1982-01-01

    Based on researches that demonstrate the presence of insulin receptor sites in hypophysis and supra renal, we investigate this hormone specific absorption by the thyroid gland. We used adult males and females Chrysemys dorbigni turtles. It was used a in vivo method consisting of [ 125 I] (2 x 10 6 cpm/Kg) insulin intra-aorta administration, and counting of the radioactivity in the gland and blood. 101 refs., 10 figs., 2 tabs

  6. Effects of hypothyroidism on vascular 125I-albumin permeation and blood flow in rats

    International Nuclear Information System (INIS)

    Tilton, R.G.; Pugliese, G.; Chang, K.; Speedy, A.; Province, M.A.; Kilo, C.; Williamson, J.R.

    1989-01-01

    Effects of hypothyroidism on vascular 125I-albumin permeation and on blood flow were assessed in multiple tissues of male Sprague-Dawley rats rendered hypothyroid by dietary supplementation with 0.5% (wt/wt) 2-thiouracil or by thyroidectomy. In both thiouracil-treated and thyroidectomized rats, body weights, kidney weight, arterial blood pressure, and pulse rate were decreased significantly v age-matched controls. After 10 to 12 weeks of thiouracil treatment, 125I-albumin permeation was increased significantly in the kidney, aorta, eye (anterior uvea, choroid, retina), skin, and new granulation tissue, remained unchanged in brain, sciatic nerve, and heart, and was decreased in forelimb skeletal muscle. A similar pattern was observed in thyroidectomized rats, except that increases in 125I-albumin permeation for all tissues were smaller than those observed in thiouracil-treated rats, and 125I-albumin permeation in retina did not differ from controls. In both thiouracil-treated and thyroidectomized rats, changes in blood flow (assessed with 15-microns, 85Sr-labeled microspheres) relative to the decrease in arterial blood pressure were indicative of a decrease in regional vascular resistance except in the choroid and in the kidney, in which vascular resistance was increased significantly. Glomerular filtration rate was decreased, but filtration fraction and urinary excretion of albumin remained unchanged by thiouracil treatment and thyroidectomy. These results indicate that vascular hemodynamics and endothelial cell barrier functional integrity are modulated in many different tissues by the thyroid. In view of the correspondence of hypothyroid- and diabetes-induced vascular permeability changes, these results raise the possibility that altered thyroid function in diabetes may play a role in the pathogenesis of diabetic vascular disease

  7. Effects of hypothyroidism on vascular /sup 125/I-albumin permeation and blood flow in rats

    Energy Technology Data Exchange (ETDEWEB)

    Tilton, R.G.; Pugliese, G.; Chang, K.; Speedy, A.; Province, M.A.; Kilo, C.; Williamson, J.R.

    1989-05-01

    Effects of hypothyroidism on vascular 125I-albumin permeation and on blood flow were assessed in multiple tissues of male Sprague-Dawley rats rendered hypothyroid by dietary supplementation with 0.5% (wt/wt) 2-thiouracil or by thyroidectomy. In both thiouracil-treated and thyroidectomized rats, body weights, kidney weight, arterial blood pressure, and pulse rate were decreased significantly v age-matched controls. After 10 to 12 weeks of thiouracil treatment, 125I-albumin permeation was increased significantly in the kidney, aorta, eye (anterior uvea, choroid, retina), skin, and new granulation tissue, remained unchanged in brain, sciatic nerve, and heart, and was decreased in forelimb skeletal muscle. A similar pattern was observed in thyroidectomized rats, except that increases in 125I-albumin permeation for all tissues were smaller than those observed in thiouracil-treated rats, and 125I-albumin permeation in retina did not differ from controls. In both thiouracil-treated and thyroidectomized rats, changes in blood flow (assessed with 15-microns, 85Sr-labeled microspheres) relative to the decrease in arterial blood pressure were indicative of a decrease in regional vascular resistance except in the choroid and in the kidney, in which vascular resistance was increased significantly. Glomerular filtration rate was decreased, but filtration fraction and urinary excretion of albumin remained unchanged by thiouracil treatment and thyroidectomy. These results indicate that vascular hemodynamics and endothelial cell barrier functional integrity are modulated in many different tissues by the thyroid. In view of the correspondence of hypothyroid- and diabetes-induced vascular permeability changes, these results raise the possibility that altered thyroid function in diabetes may play a role in the pathogenesis of diabetic vascular disease.

  8. A one-pot radiosynthesis of [125I]iodoazido photoaffinity labels

    International Nuclear Information System (INIS)

    Wilson, A.A.; Dannals, R.F.; Ravert, H.T.; Wagner, H.N. Jr.; Grigoriadis, D.E.

    1989-01-01

    A useful method for preparing radioiodinated photoaffinity labels from alkyl anilines which offer significant advantages over present methods is described. The one-pot synthesis gives good radiochemical yields (40-64%) of pure, high specific activity (350-1500 mCi/μmol) 124 I labelled iodaryl azides while minimising manipulation of radioactive materials. Purification of the [ 125 I]iodoazido photoaffinity labels is achieved by high performance liquid chromatography. (author)

  9. Autoradiographic localization of substance P receptors using 125I substance P

    International Nuclear Information System (INIS)

    Shults, C.W.; Quirion, R.; Jensen, R.T.; Moody, T.W.; O'Donohue, T.L.; Chase, T.N.

    1982-01-01

    This paper describes a method for localization of substance P receptors in the rat central nervous system using 125 I labeled substance P in an autoradiographic procedure. Particularly high densities of substance P receptors were observed in the olfactory bulb, dentate gyrus, amygdala, superior colliculus, and locus coeruleus. Surprisingly low densities of substance P receptors were found in the substantia nigra pars reticulata, a region which contains high concentrations of substance P

  10. New /sup 125/I-anti-DNA-radioimmunoassay for the diagnosis of systematic Lupus erythematosus

    Energy Technology Data Exchange (ETDEWEB)

    Neumeier, D; Vogt, W; Knedel, M [Muenchen Univ. (F.R. Germany). Inst. fuer Klinische Chemie und Klinische Biochemie

    1976-04-01

    For a differential diagnosis distinguishing between systematic lupus erythematosus and progressive and chronic polyarthritis, a special RIA method has been developed and tested. The anti-DNA activity was determined as follows: the antigen was a high-molecular double strand DNA from a human tumour cell strain biologically labelled with /sup 125/I-desoxyuridine. Free and bound antigen was separated by precipitation using saturated ammonium sulfate solution. Recovery and interassay variance of this RIA are comparable with that of other RIAs.

  11. 125I-labeled crosslinking reagent that is hydrophilic, photoactivatable, and cleavable through an azo linkage

    International Nuclear Information System (INIS)

    Denny, J.B.; Blobel, G.

    1984-01-01

    A radioactive crosslinking reagent, N-[4-(p-azido-m-[ 125 I]iodophenylazo)benzoyl]-3-aminopropyl-N'-oxysulfosuccinimide ester, has been synthesized. The reagent is photoactivatable, water-soluble, cleavable through an azo linkage, and labeled with 125 I at the carrier-free specific activity of 2000 Ci/mmol. Any protein derivatized with the reagent is thus converted into an 125 I-labeled photoaffinity probe. Crosslinks are formed following photolysis with 366-nm light, and cleavage by sodium dithionite results in the donation of radioactivity to the distal partner in crosslinked complexes. The newly labeled proteins are then analyzed by gel electrophoresis and autoradiography. The compound was prepared by iodination of N-[4-(p-aminophenylazo)benzoyl]-3-aminopropionic acid using carrier-free Na 125 I and chloramine-T, followed by azide formation and conversion to the water-soluble sulfosuccinimide ester. As a model system, protein A-Sepharose was derivatized with the reagent under subdued light. Each derivatized protein A molecule contained only one crosslinker. The derivatized protein A-Sepharose was then photolyzed in the presence of human serum and subsequently treated with sodium dithionite. Analysis of the serum by gel electrophoresis revealed that 1.1% of the radioactive label originally present on the protein A-Sepharose was transferred to the heavy chain of IgG, which was the most intensely labeled protein in the gel. The next most intensely labeled protein was IgG light chain, which incorporated radioactivity that was lower by a factor of 3.6 than that of the heavy chain. 36 references, 3 figures

  12. An indirect antibody assay using haptenated antigen and 125I-labelled anti-hapten antibody

    International Nuclear Information System (INIS)

    Aalberse, R.C.; Amsterdam Univ.

    1978-01-01

    Hapten (trinitrophenyl) was coupled to antigen (ovalbumin). The haptenated antigen was bound by anti-ovalbumin antibody and binding was quantitated with 125 I-labelled anti-hapten antibodies. Thus, with a single radioactive reagent, antibodies against a variety of antigens can be detected while the problems inherent in a labelled antiglobulin binding test are avoided. In the ovalbumin system, the haptenated antigen binding test proved to be approximately 20 times as sensitive as the iodinated ovalbumin binding test

  13. Detection of IgG antibodies against Bordetella pertussis with 125I-protein A

    International Nuclear Information System (INIS)

    Wirsing von Koenig, C.H.; Finger, H.

    1981-01-01

    A method for the detection of IgG antibodies against Bordetella pertussis is described, based on the principle of 'sandwich' radioimmunoassay. 125 I protein A is used as radioactive tracer. The influence of amounts of antigen, antibody, radioactive tracer, incubation time and temperature were tested and the optimal conditions for the assay are described. The procedure offers a simple, quick, and sensitive method for detecting antibodies against B. pertussis. Application and limitation of the test are discussed. (orig.)

  14. Laboratory of radioisotopes of IOCB ASCR - recent results of labeling by 3H and 125I

    Czech Academy of Sciences Publication Activity Database

    Elbert, Tomáš; Veselá, Iva

    2009-01-01

    Roč. 52, 7/8 (2009), s. 253-254 ISSN 0362-4803. [15th Workshop of the International Isotope Society - Central European Division: The synthesis and applications of isotopes and isotopically labelled compounds. 12.06.2009-13.06.2008, Bad Soden] Institutional research plan: CEZ:AV0Z40550506 Keywords : tritium * 125-I labeled peptides Subject RIV: CC - Organic Chemistry

  15. Investigation of thyroid parameters in farm animal by means of 125I in vitro tests

    International Nuclear Information System (INIS)

    Reinecke, P.; Leuthold, G.

    1988-01-01

    125 I in vitro tests especially thyroid hormone radioimmunoassays rendered it possible to study thyroidal activity of domestic animals even in large random tests. Parameters of thyroidal activity, such as effective T 4 quotient, T 3 value and total T 3 content, were investigated as to their connection to growth and environmental influence. The estimation of the hereditability yielded only low h 2 coefficients except in the T 3 value. All parameters studied depended to a great extent on farm conditions

  16. A radiolabeled peptide ligand of the hERG channel, [125I]-BeKm-1

    DEFF Research Database (Denmark)

    Angelo, Kamilla; Korolkova, Yuliya V; Grunnet, Morten

    2003-01-01

    The wild-type scorpion toxin BeKm-1, which selectively blocks human ether-a-go-go related (hERG) channels, was radiolabeled with iodine at tyrosine 11. Both the mono- and di-iodinated derivatives were found to be biologically active. In electrophysiological patch-clamp recordings mono-[127I]-BeKm-1...... had a concentration of half-maximal inhibition (IC50 value) of 27 nM, while wild-type BeKm-1 inhibited hERG channels with an IC50 value of 7 nM. Mono-[125I]-BeKm-1 was found to bind in a concentration-dependent manner and with picomolar affinity to hERG channel protein in purified membrane vesicles...... of [125I]-BeKm-1 to the hERG channel to an IC50 of 7 nM. In autoradiographic studies on rat hearts, binding of [125I]-BeKm-1 was dose-dependent and could partially be displaced by the addition of excess amounts of non-radioactive BeKm-1. The density of the radioactive signal was equally distributed...

  17. Characterization of [125I]endothelin-1 binding sites in rat cardiac membrane fragments

    International Nuclear Information System (INIS)

    Gu, X.H.; Casley, D.J.; Nayler, W.G.

    1989-01-01

    Standard binding and displacement techniques were used to identify high-affinity binding sites for [ 125 I]-labeled endothelin-1 (ET-1) in membranes harvested from the hearts of adult female Sprague-Dawley rats. A single population of binding sites was identified, with a KD of 0.20 +/- 0.03 nM at 37 degrees C, and a Bmax of 93.5 +/- 6.4 fmol/mg protein. Bound [ 125 I]ET-1 was displaced by ET-1 (10(-13)-10(-8) M), with a Ki of 0.08 nM. Neither (-)Bay K 8644 (10(-11)-10(-5) M), prenylamine (10(-11)-10(-5) M), (+)-cis-diltiazem (10(-10)-10(-5) M), (-)D888 (10(-10)-10(-5) M), nicardipine (10(-10)-10(-5) M), lidoflazine (10(-11)-10(-5) M), flunarizine (10(-11)-10(-5) M), omega-conotoxin (10(-13)-10(-7) M), nor prazosin (10(-10)-10(-5) M) displaced the bound ligand. Binding occurred in the absence of Ca2+ and was absent in heat-denatured membranes. These results are interpreted to mean that [ 125 I]ET-1 binds to a single class of high-affinity binding sites that differ from those occupied by known regulators of voltage activated L- and N-type Ca2+ channels

  18. 2[125I]Iodomelatonin binding sites in spleens of guinea pigs

    International Nuclear Information System (INIS)

    Poon, A.M.S.; Pang, S.F.

    1992-01-01

    2-[ 125 I]Iodomelatonin was found to bind specifically to the membrane preparations of the spleens of guinea pigs with high affinity. The binding was rapid, stable, saturable and reversible. Scatchard analysis of the binding assays revealed an equilibrium dissociation constant (Kd) of 49.8±4.12 pmol/l and binding site density (Bmax) of 0.69±0.082 fmol/mg protein at mid-light. There was no significant change in the Kd or the Bmax at mid-dark. Kinetic analysis showed a Kd of 23.13±4.81 pmol/l, in agreement to that derived from the saturation studies. The 2-[ 125 I]iodomelatonin binding sites have the following order of potency: 2-iodomelatonin > melatonin > 6-chloromelatonin much-gt N-acetylserotonin, 6-hydroxymelatonin > 5-methoxytryptamine, 5-methoxytryptophol > serotonin, 5-methoxyindole-3-acetic acid > 5-hydroxytryptophol, 3-acetylindole, 1-acetylindole-3-carboxyaldehyde, L-tryptophan > tryptamine, 5-hydroxyindole-3-acetic acid. Differential centrifugation studies showed that the binding sites are localized mainly in the nuclear fraction, the rest are distributed in the microsomal fraction, mitochondrial fraction and cytosolic fraction. The demonstration of 2-[ 125 I]iodomelatonin binding sites in the spleen suggests the presence of melatonin receptors and a direct mechanism of action of melatonin on the immune system

  19. Corrections to air kerma rate measurements of 125I brachytherapy sources to free space conditions

    International Nuclear Information System (INIS)

    Shipley, D.R.; Duane, S.

    1994-05-01

    Air kerma rate measurements have been made between 40 cm and 100 cm from one of a set of 125 I reference sources within the facilities of Amersham International plc. Monte Carlo techniques have been used to calculate the air kerma rate components over the same range of distances from this source. After comparing the calculated data with measurements, the compliance of the data with the inverse square law was investigated, and corrections were derived to obtain the air kerma rate at 1 m in free space from each source. Simulations of the experimental setup with an isotropic monoenergetic point source close to the effective energy of 125 I were found to reproduce the air kerma rate measurements reasonably accurately, and indicated that the contribution due to scattered photons was significant. The overall correction (which is defined as the product of individual corrections for chamber size effect, air attenuation and radiation scatter) required to the inverse square law to obtain the air kerma rate at 1 m in free space was found to be 0.981, 0.984 and 0.980, respectively, for air kerma rate measurements at 40 cm, 60 cm and 100 cm from the 125 I reference source. The total uncertainty in these corrections was estimated to be 0.88% at the 1σ level. (author)

  20. Differential binding of 125I-IGF-I preparations to human fibroblast monolayers

    International Nuclear Information System (INIS)

    Conover, C.A.; Misra, P.; Hintz, R.L.; Rosenfeld, R.G.

    1988-01-01

    Specific, high affinity binding of 125 I-IGF-I to the type IIGF receptor on human fibroblast monolyaers was not altered by varying feeding schedules, serum lots, washing procedures, or incubation times and temperatures. However, markedly different competitive binding curves were obtained when different iodinated IGF-I preparations were used. Five of six radioligands bound preferentially to the type IIGF receptor on human fibroblast monolayers, with 50% displacement at 4-8 μg/l unlabelled IGF-I; with one radioligand a paradoxical 20-200% increase in 125 I-IGF-I binding was observed at low concentrations of unlabelled IGF-I, while concentrations as high as 100 μg/l IGF-I failed to displace this radioligand. The latter binding pattern cannot be accounted for by 125 -I-IGF-I binding to the type II IGF receptor. These data indicate that various radioligands may have preferential affinities for different IGF-I binding sites on human fibroblast monolayers. (author)

  1. Pharmacokinetics of 125-I-labelled meta-iodo-benzyl-guanidine : Preliminary results

    International Nuclear Information System (INIS)

    Mansouri, A.; Benhidour, A. , Algiers; Algeria)

    1993-01-01

    The study of some pharmacokinetics providing the mechanism of uptake amd metabolism parameters for the 125-I-mIBG is described. NMRI mice are used for plasma binding study, the animals are killed by decapitation after intravenously (IV) injection of 125-I-mIBG. Wistar rats are used in urinary excretion study. After IV injection, animals are placed in metabolic cages to collect urine. For biodistribution, the rats are killed at different time intervals. The considered organs are removed. The radioactivity of all parameters was performed by gamma counter. The results show that the blood clearance is very high after several hours post injection and very high after 72 hours. Furthermore, we note a rapid excretion of radioactivity 24 hours post injection. However, we observe that 72 hours after injection, the radioactivity per gram of different organs was normalized according to the adrenal glands. Also, we note, that the adrenal glands may be the only target organs 48 hours post injection. These results confirm that 125-I-mIBG a high affinity for the adrenergic innervation organs (Adrenal glands, salivary glands, heart and spleen)

  2. Dopamine1 receptors in rat kidneys identified with 125I-Sch 23982

    International Nuclear Information System (INIS)

    Felder, R.A.; Jose, P.A.

    1988-01-01

    Dopamine1 receptors were studied in rat kidney using the selective dopamine1 antagonist 125I-labeled Sch 23982. The specific binding of 125I-Sch 23982 (defined by 5 microM Sch 23390) to renal cortical homogenates incubated at room temperature was rapid, saturable with time and ligand concentration, and reversible. Analysis of Rosenthal plots revealed a single class of receptors with an apparent dissociation constant of 12.2 +/- 1.9 nM and maximum receptor density of 1.03 +/- 0.15 pmol/mg protein (n = 6). However, competition experiments with the dopamine1 antagonist Sch 23390 revealed a low- and high-affinity binding site with inhibition constants of 1 x 10(-6) and 1 x 10(-8) M, respectively. The competition experiments were also indicative of dopamine1 receptors with stereoselectivity noted for dopamine1 but not for dopamine2 antagonists. The inhibition constants for dopamine1 antagonists and agonists were two orders of magnitude greater in renal cortical than striatal homogenates. Different buffers affected striatal but not renal cortical binding. Autoradiographic studies revealed 125I-Sch 23982 binding in renal cortical but not medullary tissue. These studies confirm the presence of dopamine1 receptors in the cortex of the rat kidney

  3. 125I therapy in Graves' disease. Long-term results in 355 patients

    International Nuclear Information System (INIS)

    McDougall, I.R.; Greig, W.R.

    1976-01-01

    Because of the physical and radiobiologic differences between 125 I and 131 I, a trial using 125 I to treat hyperthyroidism was undertaken in the hope of controlling hyperthyroidism without causing subsequent hypothyroidism. Three hundred fifty-five patients with diffuse toxic goitres were treated and have been under review for an average of 49.4 months: 63.4 percent are euthyroid, 33.5 percent are hypothyroid, and 3.1 percent remain hyperthyroid. Different groups of patients received a wide range of doses of 125 I (4.0 to 56.0 mCi), and the lowest incidence of hypothyroidism (23 percent) was in the group that received between 6.0 and 10.5 mCi. Sixty-three percent of the patients whose initial dose was greater than 20.0 mCi are hypothyroid. Persistent hyperthyroidism was common in patients who received small doses. Because of the high incidence of posttreatment hypothyroidism in this series and because 131 I has stood the test of time, we believe that 131 I is the radionuclide of choice for the routine treatment of hyperthyroidism

  4. Synthesis and 125I labelling of a precursor for imaging nicotinic acetylcholine receptors

    International Nuclear Information System (INIS)

    Liu Yuxia; Liu Ning; Yang Yuanyou; Zan Liangbiao; Liao Jiali; Jin Jiannan; Sichuan Univ., Chengdu

    2006-01-01

    Nicotinic Acetylcholine Receptors (nAChRs) are involved in various pharmacological effects or diseases, such as Alzheimer's Disease, Parkinson's Disease and tobacco addiction. It will be very appealing to image nAChRs in vivo, diagnose and treat the above diseases, and probe the mechanism of nAChRs in tobacco addiction if the suitable radioactive labeled compound can be synthesized. In this study, (s)-5-(tri-butylstannyl)-3{[1-(tert-butoxycarbonyl)-2-azetidinyl]methoxy} pyridine, a precursor for imaging nAChRs, was synthesized with commercial 2-furfurylamine and (s)-2-azetidinecarboxylic acid as starting materials, and was further labeled with 125/123 I. The whole procedure for radiosynthesis needs 50-55 min and more than 30% of the 125 I are found in the purified 5-[ 125 I]-A-85380. Even staying for 3 days at room temperature in vitro, the purified 5-[ 125 I]-I-85380 can maintain its stability, with a radiochemical purity of more than 95%. (authors)

  5. Clinical Significance of Accounting for Tissue Heterogeneity in Permanent Breast Seed Implant Brachytherapy Planning

    Energy Technology Data Exchange (ETDEWEB)

    Mashouf, Shahram [Medical Biophysics Department, Sunnybrook Health Sciences Centre, University of Toronto, Toronto, Ontario (Canada); Department of Radiation Oncology, Sunnybrook Odette Cancer Centre, Toronto, Ontario (Canada); Fleury, Emmanuelle [Department of Radiation Oncology, Sunnybrook Odette Cancer Centre, Toronto, Ontario (Canada); Lai, Priscilla [Medical Biophysics Department, Sunnybrook Health Sciences Centre, University of Toronto, Toronto, Ontario (Canada); Merino, Tomas [Department of Radiation Oncology, Sunnybrook Odette Cancer Centre, Toronto, Ontario (Canada); Radiotherapy Unit, School of Medicine, Departamento de Hemato-oncologia, Pontificia Universidad Católica de Chile, Santiago (Chile); Lechtman, Eli [Medical Biophysics Department, Sunnybrook Health Sciences Centre, University of Toronto, Toronto, Ontario (Canada); Kiss, Alex [Sunnybrook Research Institute, Toronto, Ontario (Canada); McCann, Claire [Department of Radiation Oncology, Sunnybrook Odette Cancer Centre, Toronto, Ontario (Canada); Pignol, Jean-Philippe, E-mail: j.p.pignol@erasmusmc.nl [Medical Biophysics Department, Sunnybrook Health Sciences Centre, University of Toronto, Toronto, Ontario (Canada); Department of Radiation Oncology, Sunnybrook Odette Cancer Centre, Toronto, Ontario (Canada); Radiation Oncology Department, Erasmus Medical Center, Cancer Institute, Rotterdam (Netherlands)

    2016-03-15

    Purpose: The inhomogeneity correction factor (ICF) method provides heterogeneity correction for the fast calculation TG43 formalism in seed brachytherapy. This study compared ICF-corrected plans to their standard TG43 counterparts, looking at their capacity to assess inadequate coverage and/or risk of any skin toxicities for patients who received permanent breast seed implant (PBSI). Methods and Materials: Two-month postimplant computed tomography scans and plans of 140 PBSI patients were used to calculate dose distributions by using the TG43 and the ICF methods. Multiple dose-volume histogram (DVH) parameters of clinical target volume (CTV) and skin were extracted and compared for both ICF and TG43 dose distributions. Short-term (desquamation and erythema) and long-term (telangiectasia) skin toxicity data were available on 125 and 110 of the patients, respectively, at the time of the study. The predictive value of each DVH parameter of skin was evaluated using the area under the receiver operating characteristic (ROC) curve for each toxicity endpoint. Results: Dose-volume histogram parameters of CTV, calculated using the ICF method, showed an overall decrease compared to TG43, whereas those of skin showed an increase, confirming previously reported findings of the impact of heterogeneity with low-energy sources. The ICF methodology enabled us to distinguish patients for whom the CTV V{sub 100} and V{sub 90} are up to 19% lower compared to TG43, which could present a risk of recurrence not detected when heterogeneity are not accounted for. The ICF method also led to an increase in the prediction of desquamation, erythema, and telangiectasia for 91% of skin DVH parameters studied. Conclusions: The ICF methodology has the advantage of distinguishing any inadequate dose coverage of CTV due to breast heterogeneity, which can be missed by TG43. Use of ICF correction also led to an increase in prediction accuracy of skin toxicities in most cases.

  6. Measurement of hepatic blood flow in the unanesthetized rabbit using 198Au and 125I rose bengal clearance technique

    International Nuclear Information System (INIS)

    Balabaud, C.; Roche, M.-C.; Dangoumau, Jacques

    1975-01-01

    Hepatic blood flow was measured in the unanesthetized rabbit using the clearance technique of 198 Au and 125 I RB. The values are: 71.82+-16.24ml.min -1 .kg -1 for 198 Au, and 60.21+-9.94ml.min -1 .kg -1 for 125 I RB (P 198 Au [fr

  7. Autoradiographic evidence of sup 125 I-. beta. -endorphin binding sites in the articular cartilage of the rat

    Energy Technology Data Exchange (ETDEWEB)

    Castano, M.T.; Freire-Garabal, M.; Giraldez, M.; Nunez, M.J.; Belmonte, A.; Couceiro, J.; Jorge, J. (Univ. of Santiago (Spain))

    1991-01-01

    After {sup 125}I-{beta}-endorphin was intravenously injected to rats, an autoradiographic study of distal femur articular cartilage was performed. Results show a specific binding of {sup 125}I-{beta}-endorphin to chondrocytes, suggesting the possible existence of an opiate modulation of articular cartilage.

  8. Effect of body size on accumulation and distribution of 125I in the green mussel (Perna Viridis)

    International Nuclear Information System (INIS)

    Chen Shunhua; Shi Qiong; Zhao Xiaokui

    1997-10-01

    Effect of body size on accumulation and distribution of 125 I in the green mussel (Perna Viridis), has been studied. The results showed that concentration capacity of every part in smaller mussels was higher than that in larger ones. Concentration factors of 125 I in byssus (about 0.5 x 10 3 ∼1.5 x 10 3 ), the highest in all parts of the mussels, were 30∼200 times as that in soft tissues, 200∼600 times as that in feet, 600∼1000 times as that in shells. Although wet weight of byssus was no more than 1% of whole body's wet weight, the content of 125 I accumulated in it accounted for as high as 75% of total 125 I content. The relationship between concentration factor of 125 I in byssus and whole body's wet weight (or shell length) can be described as a negative power function. (16 refs., 2 figs., 3 tabs.)

  9. 125I-iomazenil - benzodiazepine receptor binding and serum corticosterone level during psychological stress in a rat model

    International Nuclear Information System (INIS)

    Fukumitsu, Nobuyoshi; Ogi, Shigeyuki; Uchiyama, Mayuki; Mori, Yutaka

    2004-01-01

    To test the hypothesis that benzodiazepine receptor density decreases in response to stress, we correlated 125 I-iomazenil ( 125 I-IMZ) binding with serum corticosterone levels in a rat model. Wistar male rats were divided into four groups; control group (CON, 10 rats), no physical or psychological stress; and one-, three-, and five-day stress groups of 12 rats each (1-DAY, 3-DAY, and 5-DAY, respectively), receiving psychological stress for the given number of days. Psychological stress were given to rats with a communication box. The standardized uptake value (SUV) of 125 I-iomazenil of the 3-DAY and 5-DAY showed that 125 I-iomazenil - benzodiazepine receptor binding was significantly reduced in the cortices, accumbens nuclei, amygdala and caudate putamen (p 125 I-IMZ is a useful radioligand to reflect received stress and its binding in the cortices, accumbens nuclei, amygdala and caudate putamen is strongly affected by psychological stress

  10. Benzodiazepine effect of 125I-iomazenil-benzodiazepine receptor binding and serum corticosterone level in a rat model

    International Nuclear Information System (INIS)

    Fukumitsu, Nobuyoshi; Ogi, Shigeyuki; Uchiyama, Mayuki; Mori, Yutaka

    2005-01-01

    To test the change in free or unoccupied benzodiazepine receptor (BZR) density in response to diazepam, we investigated 125 I-iomazenil ( 125 I-IMZ) binding and serum corticosterone levels in a rat model. Wistar male rats, which received psychological stress using a communication box for 5 days, were divided into two groups according to the amount of administered diazepam: no diazepam [D (0)] group and 10 mg/kg per day [D (10)] group of 12 rats each. The standardized uptake value (SUV) of 125 I-IMZ of the D (10) group were significantly lower (P 125 I-IMZ, it is clear that diazepam competed with endogenous ligand for the free BZR sites, and the frontal, parietal and temporal cortices, globus pallidus, hippocampus, amygdala and hypothalamus are important areas in which 125 I-IMZ binding is strongly affected by administration of diazepam

  11. Automated matching of corresponding seed images of three simulator radiographs to allow 3D triangulation of implanted seeds

    Science.gov (United States)

    Altschuler, Martin D.; Kassaee, Alireza

    1997-02-01

    To match corresponding seed images in different radiographs so that the 3D seed locations can be triangulated automatically and without ambiguity requires (at least) three radiographs taken from different perspectives, and an algorithm that finds the proper permutations of the seed-image indices. Matching corresponding images in only two radiographs introduces inherent ambiguities which can be resolved only with the use of non-positional information obtained with intensive human effort. Matching images in three or more radiographs is an `NP (Non-determinant in Polynomial time)-complete' problem. Although the matching problem is fundamental, current methods for three-radiograph seed-image matching use `local' (seed-by-seed) methods that may lead to incorrect matchings. We describe a permutation-sampling method which not only gives good `global' (full permutation) matches for the NP-complete three-radiograph seed-matching problem, but also determines the reliability of the radiographic data themselves, namely, whether the patient moved in the interval between radiographic perspectives.

  12. In vivo binding of 125I-LSD to serotonin 5-HT2 receptors in mouse brain

    International Nuclear Information System (INIS)

    Hartig, P.R.; Scheffel, U.; Frost, J.J.; Wagner, H.N. Jr.

    1985-01-01

    The binding of 125 I-LSD (2-[ 125 I]-lysergic acid diethylamide) was studied in various mouse brain regions following intravenous injection of the radioligand. The high specific activity of 125 I-LSD enabled the injection of low mass doses (14ng/kg), which are well below the threshold for induction of any known physiological effect of the probe. The highest levels of 125 I-LSD binding were found in the frontal cortex, olfactory tubercles, extra-frontal cortex and striatum while the lowest level was found in the cerebellum. Binding was saturable in the frontal cortex but increased linearly in the cerebellum with increasing doses of 125 I-LSD. Serotonergic compounds potently inhibited 125 I-LSD binding in cortical regions, olfactory tubercles, and hypothalamus but had no effect in the cerebellum. Dopaminergic compounds caused partial inhibition of binding in the striatum while adrenergic compounds were inactive. From these studies the authors conclude that 125 I-LSD labels serotonin 5-HT 2 receptor sites in cortical regions with no indication that other receptor sites are labeled. In the olfactory tubercles and hypothalamus, 125 I-LSD labeling occurs predominantly or entirely at serotonic 5-HT 2 sites. In the striatum, 125 I-LSD labels approximately equal proportions of serotonergic and dopaminergic sites. These data indicate that 125 I-LSD labels serotonin receptors in vivo and suggests that appropriate derivatives of 2I-LSD may prove useful for tomographic imaging of serotonin 5-HT 2 receptors in the mammalian cortex

  13. Dosimetry consequences of the accuracy at the position of the seeds in a seeds implant of I-125 in prostate; Consecuencias dosimetricas de la exactitud en la posicion de las semilla en un implante de semillas de I-125 en prostata

    Energy Technology Data Exchange (ETDEWEB)

    Luquero Llopis, N.; Ferrer Gracia, C.; Huertas Martinez, C.; Huerga Cabrerizo, C.; Corredoira Silva, E.; Serrada Hierro, A.

    2013-07-01

    The quality control of equipment used to carry out implants of seeds of low rate in prostate, van destined to watch, the activity of seeds and the calculation of planning both positioning them on the inside of the patient. The objective of this work is, using the Nucletron Spot Pro and SeedSelectron, rating dosimetry possible consequences related to the position of the seeds. (Author)

  14. Bioactivity assays and application of 125I labeled human mouse chimeric anti-CD22 monoclonal antibody SM03

    International Nuclear Information System (INIS)

    Lu Pingping; Meng Zhiyun; Dou Guifang; Wu Yingliang; Wang Minwei

    2008-01-01

    To investigate the bioactivity and application of 125 I labeled human mouse chimeric monoclonal SM03, SM03 was labeled with 125 I using Indogen method. The labeled mixture was purified by Sephacryl S-300 HR separation chromospectry. The purity and concentration of separated fractions were determined by HPLC and Protein Assay Kit, respectively. Competitive binding method and ELISA method were used for bioactivity assays. 125 I-SM03 was applied to screen cell lines which express the most abundant CD22 antigen. The purity and recovery of 125 I-SM03 were >99% and >47%, respectively. The bioactivity of 125 I- SM03 and SM03 hasn't significant difference in statistics. Ramos cell line had the strongest special radioactivity when 125 I-SM03 bound with in Raji, Daudi and Ramos cell lines. Indogen method is a good way to label Human mouse chimeric anti-CD22 monoclonal antibody SM03 and the label will not affect the activity of SM03. The 125 I-SM03 not only can be used for detect agent, but also may be put into market for NHL therapy. (authors)

  15. 125I-human epidermal growth factor specific binding to placentas and fetal membranes from varoius pregnancy states

    International Nuclear Information System (INIS)

    Hofmann, G.E.; Siddiqi, T.A.; Rao, Ch. V.; Carman, F.R.

    1988-01-01

    Specific binding of 125 I-human epidermal growth factor (hEGF) to homogenates of term human placentas and fetal membranes from normal and appropriate for gestational age (N = 20), intrauterine growth retarded (N = 9), twin (N = 11), White class A/B diabetic (N = 12), and large for gestational age (N = 13) pregnancies was measured. In all pregnancy states, placentas bound approximately four times more 125 I-hEGF than did fetal membranes (P 125 I-hEGF binding to fetal membranes from the various pregnancy states (P 125 I-hEGF specific binding to placentas from intrauterine growth retarded or twin pregnancies was significantly greater compared with placentas from normal and appropriate for gestational age pregnancies (P 125 I-hEGF specific binding did not differ between placentas from intrauterine growth retarded or twin pregnancies (P 125 I-hEGF binding did not vary with fetal sex, maternal race, placental weight, or gestational age between 37 to 42 weeks (P 125 I-hEGF binding increased with increasing infant weight when appropriate for gestational age and large for gestational age infants were included (P<0.05, r = 0.38, N = 32) but not for intrauterine growth retarded, appropriate for gestational age, or large for gestational age infants alone. (author)

  16. A study of thyroid contaminations with 125I and of their blocking

    International Nuclear Information System (INIS)

    Ribela, Maria Teresa de Carvalho Pinto

    1996-01-01

    A sensitive method for the detection of 125 I contaminations of the thyroid was set up, the uptakes being determined by comparison with a standard curve, obtained by placing various calibrated sources of in a neck phantom. The detector efficiency was of the order of 0.25% with a stability of +- 0.011% (CV=4.4%) over a six month period. Accuracy was also confirmed, while precision studies showed an inter measurement coefficient of variation of 2 - 6 % when the measured activities were above 1 kBq. Sensitivity determined according to two different definitions ranged between 30 and 80 Bq. Thirty workers, performing routine 125 I labeling in several laboratories of the city of Sao Paulo (Brazil), were monitored, 25 of which (83%) presented significant thyroid contaminations, the maximum being 24 kBq (650 nCi) at the moment of first detection. In five individuals the effective half-life of life of 125 I could also be calculated, with enough precision, resulting in a value of 39.4 +- 6.1 d. With basis on these findings and methodology a study was carried out in an animal model (dog) in order to find an useful correlation between maximum thyroid uptake and radioiodine urinalysis at a certain time after contamination, that still could allow the intervention with an adequate blocking agent. The best correlation was found considering 125 I thyroid uptake 48 hours (T-48) and urine radioactivity 4 to 6 hours (U-4, U-5, U-6) after contamination (r = 0.974 with a level of significance p T-48 = 0.790 X U-4 + 2.973. could also be calculated, with enough precision, resulting in a value of 39.4 +- 6.1 d. With basis on these findings and methodology a study was carried out in an animal model (dog) in order to find an useful correlation between maximum thyroid uptake and radioiodine urinalysis at a certain time after contamination, that still could allow the intervention with an adequate blocking agent. The best correlation was found considering 125 I thyroid uptake 48 hours (T-48

  17. Complementary method of analyzing the quality of the implant I-125 seeds for prostate brachytherapy using ultrasound imaging post-implant

    International Nuclear Information System (INIS)

    Jimenez Dominguez, M.; Carrasco Herrera, M.; Baeza Trujillo, M.; Herrador Cordoba, M.

    2011-01-01

    In this paper we propose a complementary method based on Longitudinal mode ultrasound images acquired the same day of surgery, at the end of the implant. This option will allow us to evaluate the dosimetry end of treatment with the patient in the same position he was planning and to the rectum and bladder just as full. This will permit the identification of bodies and the seeds of interest more easily and will have a reference with which to compare one month later, when the CT images can also detect whether there has been some migration.

  18. Transport of 125I-albumin across normal and deendothelialized rabbit thoracic aorta in vivo

    International Nuclear Information System (INIS)

    Ramirez, C.A.; Colton, C.K.; Smith, K.A.; Stemerman, M.B.; Lees, R.S.

    1984-01-01

    Transmural concentration profiles of 125 I-albumin in vivo were measured across the normal and balloon catheter-deendothelialized rabbit descending thoracic aorta as a function of time following intravenous injection. A tracer was injected 5 or 60 minutes after deendothelialization, and the animals were sacrificed after circulation times of 10, 30 or 60 minutes. The aorta was immediately excised and frozen flat between glass slides. Samples were serially sectioned parallel to the intimal surface in a refrigerated microtome, washed with trichloroacetic acid (TCA), and counted. Relative tissue concentration profiles of TCA-precipitable radioactivity from the media of control animals showed entry from both luminal and adventitial sides, as previously found with conscious normal rabbits, but spatial gradients at both luminal and medial-adventitial borders were less steep. Relative concentration levels in ballooned animals were 10- to 40-fold higher than in controls, and the profiles were flatter. Uptake rates at equivalent circulation times were greater in experiments initiated 60 minutes, as compared with 5 minutes, after deendothelialization, suggesting that progressive medial edema may have occurred following balloon injury. These results show that the intact endothelium is the dominant mass transfer resistance for 125 I-albumin transport across the aortic wall. The data also suggest that the incomplete monolayer of platelets adherent to the subendothelium after balloon deendothelialization is not a substantial resistance to transport, as compared to that of the media, and that convection plays a more important role than diffusion for 125 I-albumin transport across the deendothelialized aortic wall

  19. Labelling and validation of progesterone-11-α-hydroxy hemisuccinate (125I)

    International Nuclear Information System (INIS)

    Djajusman, Sukiyati; Andria, H.

    2001-01-01

    Progesteron is a steroid hormone secreted by the corpus luteum and the adrenal cortex in the hypophise gland. The hormone can be used for monitoring pregnancy and even more for the assessment of the corpus luteum in fertile woman (4). The labelling of progesterone with 125 I was carried out for tracer production in the preparation of Progesterone Kit used in the determination of the progesterone derivate has been done. The labelling was carried out in two steps reaction. First the progesterone derivate was activated using N-methyl morpholine and isobutylchloroformate. The second step was performed by conjugating the labelled 125 I Histamin to the activated progesterone derivate. The labelled compound was purified with HPLC followed with the determination of the chemical purity using electrophorosis, the immunoreactivity controlled with the maximum binding of the zerro standard and the non specific binding using the Progesterone Kit. Experimental results showed that the iodination of Progesterone -11-α-hidroxy hemisuccinate ( 125 I) yield 22.15%, chemical purity 92.30%, the radioimmunoreactivity 51% as maximum binding (for zero standard), with NSB 0.67%, and the spesific activity obtained 7.72 Ci/ g. Validation of the tracer using control (low, medium and high) shows the results as follows : (2.72 ± 0.49)nmol/L for low standard and control (1.2 - 2.5 nmol/L), (11.3 ± 1.15) nmol/L for medium standard and control (6-15 n/mol) and (15.95 ± 5.32 ) nmol/L for high standard and control (10-23 nmol/L). The sensitivity of the assay was (0.70 ± 0.024 nmol/L) for zero standard

  20. Labelling of. beta. -endorphin (. beta. -END) and. beta. -lipotropin (. beta. -LPH) by /sup 125/I

    Energy Technology Data Exchange (ETDEWEB)

    Deby-Dupont, G.; Joris, J.; Franchimont, P. (Universite de Liege (Belgique)); Reuter, A.M.; Vrindts-Gevaert, Y. (Institut des Radioelements, Fleurus (Belgique))

    1983-01-01

    5 ..mu..g of human ..beta..-endorphin were labelled with 2 mCi /sup 125/I by the chloramine T technique. After two gel filtrations on Sephadex G-15 and on Sephadex G-50 in phosphate buffer with EDTA, Trasylol and mercapto-ethanol, a pure tracer was obtained with a specific activity about 150 ..mu..Ci/..mu..g.Kept at + 4/sup 0/C, the tracer remained utilizable for 30 days without loss of immunoreactivity. The labelling with lactoperoxydase and the use of another gel filtration method (filtration on Aca 202) gave a /sup 125/I ..beta..-END tracer with the same immunoreactivity. The binding of this tracer to the antibody of an anti-..beta..-END antiserum diluted at 1/8000 was 32% with a non specific binding of 2%. 5 ..mu..g of human ..beta..-lipotropin were labelled with 0.5 mCi /sup 125/I by the lactoperoxydase method. After two gel filtrations on Sephadex G-25 and on Sephadex G-75 in phosphate buffer with EDTA, Trasylol and mercapto-ethanol, a pure tracer with a specific activity of 140 ..mu..Ci/..mu..g was obtained. It remained utilizable for 30 days when kept at + 4/sup 0/C. Gel filtration on Aca 202 did not give good purification, while gel filtration on Aca 54 was good but slower than on Sephadex G-75. The binding to antibody in absence of unlabelled ..beta..-LPH was 32% for an anti-..beta..-LPH antiserum diluted at 1/4000. The non specific binding was 2.5%.

  1. Specific binding of 125I-salmon calcitonin to rat brain

    International Nuclear Information System (INIS)

    Nakamuta, Hiromichi; Furukawa, Shinichi; Koida, Masao; Yajima, Haruaki; Orlowski, R.C.

    1981-01-01

    Rat brain particulate fraction was found to contain binding sites for 125 I-Salmon Calcitonin-I ( 125 I-SCT). Maximum binding occurred in the physiological pH range of 7.25 - 7.5. The binding reaction proceeded in a temperature-dependent manner. Binding sites were broadly distributed among the various rat brain regions and considerable regional differences existed in the affinity and density as detected by Scatchard analysis. The highest affinity was recorded in the case of the hypothalamus and the lowest in the case of the cerebellum. The KD (nM) and Bmax (pmole/mg protein) estimated for the binding to four regions were as follows: hypothalamus: 1.4 and 0.19, midbrain, hippocampus plus striatum: 1.5 and 0.08, pon plus medulla oblongata: 3.0 and 0.15 and cerebellum: 8.3 and 0.20. Using a particulate fraction of rat brain void of cerebellum and cortices, a binding assay for calcitonins was developed. Binding of 125 I-SCT was inhibited by unlabeled salmon, [Asu sup(1,7)]-eel and porcine calcitonins in a dose-dependent manner and the IC50s were 2.0, 8.0 and 30 nM, respectively. The IC50s were comparable to those estimated using a kidney particulate fraction. Human calcitonin, β-endorphin and substance P were weak inhibitors of the binding. Other peptides, drugs and putative neurotransmitters tested (totally 23 substances) failed to inhibit the binding at concentrations of 1.0 μM. The physiological significance of brain binding sites for calcitonin, with the possibility that the brain may possess endogenous ligands for these sites are discussed. (author)

  2. Specific uptake, dissociation, and degradation of 125I-labeled insulin in isolated turtle (Chrysemys dorbigni) thyroid glands

    International Nuclear Information System (INIS)

    Marques, M.; da Silva, R.S.; Turyn, D.; Dellacha, J.M.

    1985-01-01

    Thyroid glands from turtles (Chrysemys dorbigni) pretreated with potassium iodide were incubated with 125 I-insulin in the presence or absence of unlabeled insulin, in order to study its specific uptake. At 24 degrees, the specific uptake reached a plateau at 180 min of incubation. The dose of bovine insulin that inhibited 50% of the 125 I-insulin uptake was 2 micrograms/ml of incubation medium. Most of the radioactive material (71%) extracted from the gland, after 30 min incubation with 125 I-insulin, eluted in the same position as labeled insulin on Sephadex G-50. Only 24% eluted in the salt position. After 240 min incubation, increased amount of radioactivity appeared in the Na 125 I position. When bovine insulin was added together with the labeled hormone, a substantial reduction of radioactivity was observed in the insulin and Na 125 I elution positions. Dissociation studies were performed at 6 degrees in glands preincubated with 125 I-insulin either at 24 or 6 degrees. The percentage of trichloroacetic acid (TCA)-soluble radioactive material in the dissociation medium increased with incubation time at both temperatures. However, the degradation activity was lower at 6 than at 24 degrees. The addition of bovine insulin to the incubation buffer containing 125 I-insulin reduced the radioactive degradation products in the dissociated medium. Chloroquine or bacitracin inhibited the degradation activity. Incubation of thyroid glands with 125 I-hGH or 125 I-BSA showed values of uptake, dissociation, and degradation similar to those experiments in which an excess of bovine insulin was added together with the labeled hormone. Thus, by multiple criteria, such as specific uptake, dissociation, and degradation, the presence of insulin-binding sites in the turtle thyroid gland may be suggested

  3. Retrograde axonal transport of 125I-nerve growth factor in rat ileal mesenteric nerves. Effect of streptozocin diabetes

    International Nuclear Information System (INIS)

    Schmidt, R.E.; Plurad, S.B.; Saffitz, J.E.; Grabau, G.G.; Yip, H.K.

    1985-01-01

    The retrograde axonal transport of intravenously (i.v.) administered 125 I-nerve growth factor ( 125 I-NGF) was examined in mesenteric nerves innervating the small bowel of rats with streptozocin (STZ) diabetes using methods described in detail in the companion article. The accumulation of 125 I-NGF distal to a ligature on the ileal mesenteric nerves of diabetic animals was 30-40% less than in control animals. The inhibition of accumulation of 125 I-NGF in diabetic animals was greater at a ligature tied 2 h after i.v. administration than at a ligature tied after 14 h, which suggests that the diabetic animals may have a lag in initiation of NGF transport in the terminal axon or retardation of transport at some site along the axon. The 125 I-NGF transport defect was observed as early as 3 days after the induction of diabetes, a time before the development of structural axonal lesions, and did not worsen at later times when dystrophic axonopathy is present. Both the ileal mesenteric nerves, which eventually develop dystrophic axonopathy in experimental diabetes, and the jejunal mesenteric nerves, which never develop comparable structural alterations, showed similar 125 I-NGF transport deficits, suggesting that the existence of the transport abnormality does not predict the eventual development of dystrophic axonal lesions. Autoradiographic localization of 125 I-NGF in the ileal mesenteric nerves of animals that had been diabetic for 11-13 mo demonstrated decreased amounts of 125 I-NGF in transit in unligated paravascular nerve fascicles. There was, however, no evidence for focal retardation of transported 125 I-NGF at the sites of dystrophic axonal lesions

  4. WE-AB-BRA-11: Improved Imaging of Permanent Prostate Brachytherapy Seed Implants by Combining an Endorectal X-Ray Sensor with a CT Scanner

    International Nuclear Information System (INIS)

    Steiner, J; Matthews, K; Jia, G

    2016-01-01

    Purpose: To test feasibility of the use of a digital endorectal x-ray sensor for improved image resolution of permanent brachytherapy seed implants compared to conventional CT. Methods: Two phantoms simulating the male pelvic region were used to test the capabilities of a digital endorectal x-ray sensor for imaging permanent brachytherapy seed implants. Phantom 1 was constructed from acrylic plastic with cavities milled in the locations of the prostate and the rectum. The prostate cavity was filled a Styrofoam plug implanted with 10 training seeds. Phantom 2 was constructed from tissue-equivalent gelatins and contained a prostate phantom implanted with 18 strands of training seeds. For both phantoms, an intraoral digital dental x-ray sensor was placed in the rectum within 2 cm of the seed implants. Scout scans were taken of the phantoms over a limited arc angle using a CT scanner (80 kV, 120–200 mA). The dental sensor was removed from the phantoms and normal helical CT and scout (0 degree) scans using typical parameters for pelvic CT (120 kV, auto-mA) were collected. A shift-and add tomosynthesis algorithm was developed to localize seed plane location normal to detector face. Results: The endorectal sensor produced images with improved resolution compared to CT scans. Seed clusters and individual seed geometry were more discernable using the endorectal sensor. Seed 3D locations, including seeds that were not located in every projection image, were discernable using the shift and add algorithm. Conclusion: This work shows that digital endorectal x-ray sensors are a feasible method for improving imaging of permanent brachytherapy seed implants. Future work will consist of optimizing the tomosynthesis technique to produce higher resolution, lower dose images of 1) permanent brachytherapy seed implants for post-implant dosimetry and 2) fine anatomic details for imaging and managing prostatic disease compared to CT images. Funding: LSU Faculty Start-up Funding

  5. WE-AB-BRA-11: Improved Imaging of Permanent Prostate Brachytherapy Seed Implants by Combining an Endorectal X-Ray Sensor with a CT Scanner

    Energy Technology Data Exchange (ETDEWEB)

    Steiner, J; Matthews, K; Jia, G [Louisiana State University, Baton Rouge, LA (United States)

    2016-06-15

    Purpose: To test feasibility of the use of a digital endorectal x-ray sensor for improved image resolution of permanent brachytherapy seed implants compared to conventional CT. Methods: Two phantoms simulating the male pelvic region were used to test the capabilities of a digital endorectal x-ray sensor for imaging permanent brachytherapy seed implants. Phantom 1 was constructed from acrylic plastic with cavities milled in the locations of the prostate and the rectum. The prostate cavity was filled a Styrofoam plug implanted with 10 training seeds. Phantom 2 was constructed from tissue-equivalent gelatins and contained a prostate phantom implanted with 18 strands of training seeds. For both phantoms, an intraoral digital dental x-ray sensor was placed in the rectum within 2 cm of the seed implants. Scout scans were taken of the phantoms over a limited arc angle using a CT scanner (80 kV, 120–200 mA). The dental sensor was removed from the phantoms and normal helical CT and scout (0 degree) scans using typical parameters for pelvic CT (120 kV, auto-mA) were collected. A shift-and add tomosynthesis algorithm was developed to localize seed plane location normal to detector face. Results: The endorectal sensor produced images with improved resolution compared to CT scans. Seed clusters and individual seed geometry were more discernable using the endorectal sensor. Seed 3D locations, including seeds that were not located in every projection image, were discernable using the shift and add algorithm. Conclusion: This work shows that digital endorectal x-ray sensors are a feasible method for improving imaging of permanent brachytherapy seed implants. Future work will consist of optimizing the tomosynthesis technique to produce higher resolution, lower dose images of 1) permanent brachytherapy seed implants for post-implant dosimetry and 2) fine anatomic details for imaging and managing prostatic disease compared to CT images. Funding: LSU Faculty Start-up Funding

  6. Detection of human spermatozoal peptides after conjugation to 125I-labelled human serum albumin

    International Nuclear Information System (INIS)

    Metler, L.; Skrabei, H.; Czuppon, A.B.

    1981-01-01

    Human spermatozoal peptides, liberated during autolysis of the cells, were fractionated by gel-filtration chromatography and thin-layer chromatography. After conjugation to 125 I-labelled human serum albumin, all fractions were assayed with rabbit antihuman spermatozoa antiserum. In earlier publications, human sperm-immobilizing and sperm-agglutinating sera were used for the detection of solubilized spermatozoal antigen. The low sensitivity of these tests necessitated a more sensitive test. The purpose of this work is to describe a solid-phase radioimmunoassay for the detection of antigenic peptides

  7. Application of 125I radioimmunoassay to measure inhibition of precipitin reactions using carbohydrate-specific antibodies

    International Nuclear Information System (INIS)

    Boullanger, P.H.; Nagpurkar, A.; Noujaim, A.A.; Lemieux, R.U.

    1978-01-01

    Antibodies raised to an artificial antigen with β-D-galactopyranosyl groups as antigenic determinants were purified using an immunoadsorbent prepared from the hapten involved in the synthesis of the antigen. In order to study the specificity of these antibodies, 125 I radiolabelling of either the artificial antigen or the antibody was used in the study of inhibitions of the precipitin reaction. The method, involving labelling of the artificial antigen and counting radioactivity in the supernatant, was found to be more accurate and faster than the usual methods based on measuring the amount of protein precipitated by chemical or spectroscopic methods. (author)

  8. Synthesis and 125I labeling of N-succinimidyl-3-(tri-n-butylstannyl)benzoate

    International Nuclear Information System (INIS)

    Liu Zhenfeng; Wang Yongxian; Zhou Wei; Wang Lihua; Xia Jiaoyun; Yin Duanzhi

    2005-01-01

    N-succinimidyl-3-(tri-n-butylstannyl)benzoate (ATE) and N-succinimidyl-3-iodo-benzoate (SIB) is synthesized. The structures of ATE and SIB are confirmed with 1 HNMR, MS and IR. The yields of ATE and SIB are 45.4% and 71.4%, respectively. ATE is labeled with 125 I. The labeling field is 93.0% and radiochemical purity is over 98.0%. The synthesis and the labeling of ATE have a important value for indirect label of radiopharmaceuticals. (authors)

  9. Secretin radioimmunoassay using 125I-6-tyrosyl-secretin (6TS)

    International Nuclear Information System (INIS)

    Raptis, S.; Leitze, M.; Schlegel, W.; Pfeiffer, E.F.

    1975-01-01

    In radioimmunological determination of secretin difficulties are caused by the following two problems: firstly, in raising potent antibodies, and secondly in satisfactory labeling. All secretin RIAs described in the literature were carried out with traditional synthetic secretin (Young, Lazarus, Chisholm and Atkinson 1968; Boden and Chey 1973; Holohan, Murphy, Buchanan and Elmore 1973; Boehm, Lee and Chey 1974). Our study describes the development of an assay with sufficient sensitivity to measure circulating immunoreactive secretin in human blood, by using 125 I-6-TS, which is a product of Schwarz and Mann/USA (SM). (orig.) [de

  10. Penicillin-binding proteins of Escherichia coli identified with a 125I-derivative of ampicillin

    International Nuclear Information System (INIS)

    Schwarz, U.; Seeger, K.; Wengenmayer, F.; Strecker, H.

    1981-01-01

    Evaluation of the binding of β-lactam antibiotics to penicillin-binding proteins (PBPs) in the bacterial cell wall by the established method using 14 C-labelled penicillin G has some disadvantages. Due to the small number of PBP molecules and the relatively low specific activity of [ 14 C]penicillin G available, very long exposure times for autoradiography are required. Furthermore, additional radiolabelled derivatives of penicillin with modified binding patterns might reveal PBPs not known so far. The authors describe the synthesis of a 125 I-labelled derivative of ampicillin and the labelling of PBPs with this compound. (Auth.)

  11. Thrombus detection using 125I-fibrinogen and a CdTe probe

    International Nuclear Information System (INIS)

    Garcia, D.A.; Frisbie, J.H.; Tow, D.E.; Sasahara, A.A.; Entine, G.

    1976-01-01

    A compact CdTe detector system was developed for use in a clinical screening test for venous thrombosis of the legs. Patients given intravenously administered autologous 125 I-fibrinogen were probed externally at selected points on the thighs and calves for abnormal accumulations of radioactivity. Measurements made with the CdTe probe were compared to those obtained with a standard portable NaI detector system. The CdTe probe was the equal of the NaI detector in diagnostic capability. The compact design of the semiconductor system considerably eased the probing procedure, especially in bedridden patients with limited mobility of the extremities

  12. Removal of 125I from radioactive experimental waste with an anion exchange paper membrane

    International Nuclear Information System (INIS)

    Inoue, Hiroyoshi; Kagoshima, Mayumi

    2000-01-01

    The behavior of radioactive iodide and chloride ions through an anion exchange paper membrane to remove 125 I from radioactive experimental waste has been studied with nonequilibrium thermodynamic analyses. Anion exchange paper membrane was found to be electroconductively more permeable to iodide ion than to chloride ion. The iodide ion bound more strongly to the anion exchange site within a membrane phase than the chloride ion by more than twice. The results suggested that an anion exchange paper membrane was appropriate for the filtration removal system

  13. A new 125I-anti-DNA-radioimmunoassay for the diagnosis of systematic Lupus erythematosus

    International Nuclear Information System (INIS)

    Neumeier, D.; Vogt, W.; Knedel, M.

    1976-01-01

    For a differential diagnosis distinguishing between systematic lupus erythematosus and progressive and chronic polyarthritis, a special RIA method has been developed and tested. The anti-DNA activity was determined as follows: the antigen was a high-molecular double strand DNA from a human tumour cell strain biologically labelled with 125 I-desoxyuridine. Free and bound antigen was separated by precipitation using saturated ammonium sulfate solution. Recovery and interassay variance of this RIA are comparable with that of other RIAs. (GSE) [de

  14. Changes in protein metabolism after gastric resection studied by 125I-albumin

    International Nuclear Information System (INIS)

    Beno, I.; Cerven, J.

    1976-01-01

    The changes were studied in the metabolism of protein using albumin- 125 I in seven patients with benign conditions of the stomach or duodenum before gastrectomy and starting with the second week after the surgery. In the postoperative period body weight was found to be significantly reduced, there was a drop in erythrocyte count, and blood hemoglobin and plasma albumin concentration were decreased. There was a significant rise of plasma volume during this period. Compared with the preoperative findings, the intravascular albumin pool was diminished by 11%, the extravascular albumin pool by 19.%, so that the overall albumin pool was postoperatively found to be reduced by 1/6. (author)

  15. 125I-labeling and purification of peptide hormones and bovine serum albumin

    International Nuclear Information System (INIS)

    Nemeth, J; Jakab, B.; Szilvassy, Z.; Oroszi, G.; Roeth, E.; Magyarlaki, M.; Farkas, B.

    2002-01-01

    The iodination and separation of various diagnostically and/or experimentally important peptides including (Tyr 1 )-somatostatin-14, rat Tyr-α-calcitonin gene-related peptide (23-37), motilin and vasoactive intestinal peptide, furthermore bovine serum albumin are described. All species were iodinated by the iodogen method. The 125 I-labeled peptide products were separated by reversed-phase HPLC, the specific activities of mono-iodinated forms are near identical with the theoretical value. The labeled bovine serum albumin was separated by Sephadex G-100 gel filtration. (author)

  16. Correlation between the estimated molecular weight and the immunological properties of 125I-TSH

    International Nuclear Information System (INIS)

    Quiroga, S.E.; Ciscato, V.A.; Barmasch, M.; Kurcbart, H.; Veira de Giacomini, S.; Altschuler, N.; Caro, R.A.

    1976-09-01

    Thyrotropic Stimulating Hormone (TSH) was radioiodinated by the Chloramine T method in order to be used in radioimmu-noassay procedures. It was purified by gel filtration and each fraction of the eluate was analyzed in order to determine which one had the most suitable behaviour for that use. The molecular weight of each fraction was estimated, as well as its immunological reactivity and its non-specific binding. The 125 I-TSH fraction with better properties was the closest to the molecular weight of the native hormone, which is found at the posterior shoulder of the main proteic peak of the elution pattern. (author) [es

  17. Portable multiwire proportional chamber imaging system for high resolution 125I imaging

    International Nuclear Information System (INIS)

    Lazewatsky, J.L.; Lanza, R.C.; Murray, B.W.; Bolon, C.; Burns, R.E.; Szulc, M.

    1976-01-01

    A dedicated multiwire proportional chamber system designed to image 125 I labeled venous thrombi is described. The chamber is filled with a Kr-Co 2 gas mixture at one atmosphere pressure and utilizes an externally mounted delay line readout. A pair of crossed x-ray grids form a collimator which yields an optimum system efficiency of 3.1 x 10 -4 for a fixed spatial resolution of 0.74 cm. The chamber is further designed to be lightweight and portable for in-hospital use

  18. Labelling of human follicle stimulant hormone with 125I, for radioimmunoassay

    International Nuclear Information System (INIS)

    Pinto, H.; Werner, R.S.; Lerario, A.C.; Toledo e Souza, I.T. de; Wajchenberg, B.L.; Pieroni, R.R.

    1976-01-01

    An efficient labeling of human Follicle Stimulant Harmone is essential to development of sensitive radioimmunoassays. Iodination by Chloramine T method frequently is subject to severe iodination damage and some preparations are unaccetable for radioimmunoassays. Modifications to the Hunter method, changing incubation time, reaction temperature and reducing Chloramine T amount used in the reaction, were performed in obtaining a more effective labeling. FSH-125 I fraction obtained from Sephadex G-75 column purification presented excellent immunoreactivity and quality control of the steps of the reaction demonstrated a high percentage (90%) of intact Follicle Stimulant Hormone [pt

  19. Immunoassay of serum polypeptide hormones by using 125I-labelled anti(-immunoglobulin G) antibodies.

    Science.gov (United States)

    Beck, P; Nicholas, H

    1975-03-01

    1. A technique for indirectly labelling antibodies to polypeptide hormones, by combining them with radioactively labelled anti-(immunoglobulin G) is described. (a) 125I-labelled anti-(rabbit immunoglobulin G) and anti-(guinea-pig immunoglobulin G) antibodies with high specific radioactivity were prepared after purification of the antibodies on immunoadsorbents containing the respective antigens. (b) Rabbit immunoglobulin G antibodies to human growth hormone, porcine glucagon and guinea-pig immunoglobulin G antibodies to bovine insulin and bovine parathyroid hormone were combined with immunoadsorbents containing the respective polypeptide hormone antigen. (c) The immunoglobulin G antibodies to the polypeptide hormones were reacted with 125-I-labelled anti-(immunoglobulin G) antibodies directed against the appropriate species of immunoglobulin G,and the anti-hormone antibodies were combined with the hormone-containing immunoadsorbent. (d) 125I-labelled anti-(immunoglobulin G) antibodies and anti-hormone antibodies were simultaneously eluted from the hormone-containing immunoadsorbent by dilute HCl, pH 2.0. After elution the anti-(immunoglobulin G) antibodies and antihormone antibodies were allowed to recombine at pH 8.0 and 4 degrees C. 2. The resultant immunoglobulin G-anti-immunoglobulin G complex was used in immunoradiometric (labelled antibody) and two-site assays of the respective polypeptide hormone. 3. By using these immunoassays, concentrations down to 90pg of human growth hormone/ml, 100 pg of bovine insulin/ml, 80 pg of bovine parathyroid hormone/ml and 150 pg of glucagon/ml were readily detected. Assays of human plasma for growth hormone and insulin by these methods showed good agreement with results obtained by using a directly 125I-labelled anti-hormone antibody in an immunoradiometric assay of human growth hormone or by radioimmunoassay of human insulin. 4. The method described allows immunoradiometric or two-site assays to be performed starting with as

  20. The role of endorectal coil MRI in patient selection and treatment planning for prostate seed implants

    International Nuclear Information System (INIS)

    Clarke, Daniel H.; Banks, Stephen J.; Wiederhorn, A. Roger; Klousia, John W.; Lissy, Jeanne M.; Miller, Michelle; Able, Arnold M.; Artiles, Carlos; Hindle, William V.; Blair, Deborah N.; Houk, Russell R.; Sheridan, Michael J.

    2002-01-01

    Purpose: To assess the role of endorectal coil magnetic resonance imaging (MRI) staging for patients undergoing seed implantation (SI) with or without external beam radiotherapy (EBRT). Methods and Materials: Between October 1994 and December 1998, 390 patients underwent prostate SI (98% Pd-103, 2% I-125). Seventy-six percent of patients had a prostate serum antigen (PSA) 20. Ten percent of patients had a Gleason score (GS) of 4-5, 54% had GS 6, 29% had GS 7, and 7% had GS ≥ 8. Monotherapy was employed in 46% of patients, and the remaining 54% received combined EBRT and SI. Three hundred twenty-seven were staged by high-resolution phased array pelvic coil, or in most cases, an endorectal coil MRI. The MRI findings were used to guide stage-appropriate treatment recommendations, and to assist in the preplanning and optimization of seed distributions. The criteria utilized to determine MRI-based stage were founded on the reported literature from the University of Pennsylvania. All MRI studies were reviewed by C.A., D.B., or W.H., who were unaware of clinical stage at the time of their review. The biopsy report was available to them as the only clinical correlate. Results: Of the 327 patients staged by MRI, 70% were upstaged from the digital rectal examination-based clinical stage; 26% of T 1 , T 2 patients were upstaged to T 3 . Perineural invasion and the percentage of positive cores predicted for T 3 MRI stage (p 3 intermediate-risk group patients treated by combined therapy with a previous study of T 3 intermediate-risk group treated by radical prostatectomy (RP) at the University of Pennsylvania. Our 36-month PSA FFP was 94% compared with 21% for the previous study's RP patients. Conclusion: MRI is a valuable staging procedure for prostate cancer patients treated by SI. PSA FFP results appear to be improved by MRI staging. MRI T 3 disease can be treated more effectively by SI + EBRT than by RP

  1. Molecular suicide studies of 125I and 3H disintegration in the DNA of Chinese hamster cells

    International Nuclear Information System (INIS)

    Burki, H.J.; Koch, C.; Wolff, S.

    1978-01-01

    Several recent experiments are discussed which yield some new data to help further understand the dramatic sensitivity of mammalian cells to 125 I induced reproductive death. The authors discuss the effects of halogenated pyrimidines on removing the shoulder of the survival curve after tritium thymidine suicide; the effect of oxygen on 125 I decay effects as a functions of the localization of the decays within the nucleus; and recent data on the induction of chromosome aberrations by 125 I DNA decays in CHO cells stored in the G 1 -stage of the cell cycle. (B.R.H.)

  2. Migration studies of fission product nuclides in rocks. Pt.5: Diffusion and permeability of nuclide 125I in marble

    International Nuclear Information System (INIS)

    Wen Ruiyuan; Gao Hongcheng; Wang Xiangyun

    1996-01-01

    The migration behaviour of nuclide 125 I, as a simulation of the long lived fission product 129 I, in marble is studied in self-designed cells. A series of the most important parameters of diffusion and permeability (e.g., intrinsic diffusion coefficient, dispersion coefficient and interstitial flow velocity, etc.) are determined. Based on the differential equation of the nuclide migration, the distribution function and numerical solution of 125 I in marble are presented. The results show that the migration velocity of 125 I in marble is fast, indicating that it is not suitable to dispose nuclear waste in marble

  3. Aterial connective tissue changes and distribution of 125I-labelled low density lipoprotein in hypertensive pigs

    International Nuclear Information System (INIS)

    Sharpe, D.N.; Scott, P.J.; Flint, M.H.; Donald, J.

    1980-01-01

    Young pigs with hypertension of 10 weeks duration, resulting from cellophane perinephritis, were injected with 125 I-labelled low-density lipoprotein ( 125 I LDL) before being killed 24 h or 48 h later. Intimal thickening and increased acid mucopolysaccharide were demonstrated in the aortas and major arteries of the hypertensive animals. Increased accumulation of ( 125 I)LDL was observed in the inner media beneath areas of intimal thickening. It is suggested that the primary effect of hypertension in atherosclerosis is to produce structural changes in arterial connective tissue which allow increased accumulation of LDL by altering the permeability and binding properties of the arterial wall. (author)

  4. The biocompatibility of titanium cardiovascular devices seeded with autologous blood-derived endothelial progenitor cells: EPC-seeded antithrombotic Ti implants.

    Science.gov (United States)

    Achneck, Hardean E; Jamiolkowski, Ryan M; Jantzen, Alexandra E; Haseltine, Justin M; Lane, Whitney O; Huang, Jessica K; Galinat, Lauren J; Serpe, Michael J; Lin, Fu-Hsiung; Li, Madison; Parikh, Amar; Ma, Liqiao; Chen, Tao; Sileshi, Bantayehu; Milano, Carmelo A; Wallace, Charles S; Stabler, Thomas V; Allen, Jason D; Truskey, George A; Lawson, Jeffrey H

    2011-01-01

    Implantable and extracorporeal cardiovascular devices are commonly made from titanium (Ti) (e.g. Ti-coated Nitinol stents and mechanical circulatory assist devices). Endothelializing the blood-contacting Ti surfaces of these devices would provide them with an antithrombogenic coating that mimics the native lining of blood vessels and the heart. We evaluated the viability and adherence of peripheral blood-derived porcine endothelial progenitor cells (EPCs), seeded onto thin Ti layers on glass slides under static conditions and after exposure to fluid shear stresses. EPCs attached and grew to confluence on Ti in serum-free medium, without preadsorption of proteins. After attachment to Ti for 15 min, less than 5% of the cells detached at a shear stress of 100 dyne / cm(2). Confluent monolayers of EPCs on smooth Ti surfaces (Rq of 10 nm), exposed to 15 or 100 dyne/cm(2) for 48 h, aligned and elongated in the direction of flow and produced nitric oxide dependent on the level of shear stress. EPC-coated Ti surfaces had dramatically reduced platelet adhesion when compared to uncoated Ti surfaces. These results indicate that peripheral blood-derived EPCs adhere and function normally on Ti surfaces. Therefore EPCs may be used to seed cardiovascular devices prior to implantation to ameliorate platelet activation and thrombus formation. Copyright © 2010 Elsevier Ltd. All rights reserved.

  5. Simulation of measurement absorbed dose on prostate brachytherapy with radius of prostate 2 cm using MCNP5 with seed implant model isoaid AdvantageTM IAPd-103A

    International Nuclear Information System (INIS)

    Poundra Setiawan; Suharyana; Riyatun

    2015-01-01

    Simulation of measurement absorbed dose on prostate brachytherapy with radius of prostate 2 cm using MCNP5 with seed implant model IsoAid Advantage TM IAPd-103A has been conducted. 103 Pd used as a radioactive source in the seed implant and it has energy gamma emission 20,8 keV with half live 16,9 days and has activity 4 mCi. The prostate cancer is modeled with spherical and it has radius 3 cm, after planting the seed implant 103 Pdover 24,4 days, prostate cancer has absorbed dose 2,172Gy. Lethal dose maximum use 103 Pd is 125 Gy and it was reached with 59 seeds. (author)

  6. Comparison of intraoperative dosimetric implant representation with postimplant dosimetry in patients receiving prostate brachytherapy.

    Science.gov (United States)

    Stone, Nelson N; Hong, Suzanne; Lo, Yeh-Chi; Howard, Victor; Stock, Richard G

    2003-01-01

    To compare the results of intraoperative dosimetry with those of CT-based postimplant dosimetry in patients undergoing prostate seed implantation. Seventy-seven patients with T1-T3 prostate cancer received an ultrasound-guided permanent seed implant (36 received (125)I, 7 (103)Pd, and 34 a partial (103)Pd implant plus external beam radiation therapy). The implantation was augmented with an intraoperative dosimetric planning system. After the peripheral needles were placed, 5-mm axial images were acquired into the treatment planning system. Soft tissue structures (prostate, urethra, and rectum) were contoured, and exact needle positions were registered. Seeds were placed with an applicator, and their positions were entered into the planning system. The dose distributions for the implant were calculated after interior needle and seed placement. Postimplant dosimetry was performed 1 month later on the basis of CT imaging. Prostate and urethral doses were compared, by using paired t tests, for the real-time dosimetry in the operating room (OR) and the postimplant dosimetry. The mean preimplant prostate volume was 39.8 cm(3), the postneedle planning volume was 41.5 cm(3) (psystem provides a close match to the actual delivered doses. These data support the use of this system to modify the implant during surgery to achieve more consistent dosimetry results.

  7. SU-E-T-301: Dosimetric Comparison Between Adaptive and Rectilinear Template-Based Prostate Seed Implants

    Energy Technology Data Exchange (ETDEWEB)

    Sugar, E Neubauer; Buzurovic, I; O’Farrell, D; Hansen, J; Devlin, P; Cormack, R; Nguyen, P [Brigham and Women’s Hospital, Boston, MA (United States)

    2015-06-15

    Purpose: To compare the dosimetry of a standard rectilinear and an adaptive technique used in I125 prostate seed implants. Methods: To achieve favorable dosimetry in prostate implants we used adaptive needle updates to match actual positions in real-time. The seed locations were optimized based on actual needle locations. The seeds were delivered automatically with a robotic device seedSelectron™ (Elekta Brachytherapy). In this study, we evaluated the former approach against the standard rectilinear technique in which the needles have a parallel distribution. The treatment plans for 10 patients were analyzed. For comparison, the actual treatment plans were revised so each needle was repositioned to its original parallel location through the template. The analysis was performed by comparing the target coverage and dose to the organs at risk. The comparison was done using the following planning goals: the target D90> 90%, V100% > 90%, V50% <70% and V200% <30%; the urethra V125% < 1cm3 and V150%= 0cm3; and the Rectum V100%<1cm3 and V69% < 8cm3. The prescription dose to the target was 145Gy. Results: The average target volume and number of seeds were 44.39cm3(SD=11.14) and 74(SD=12), respectively. The D90 for adaptive and rectilinear plans was 159.9Gy(SD=2.99) and 155.53Gy(SD=4.04) resulting in a 2.74% difference for the average target coverage. A similar difference (1.75%) was noticed in the target V100[%]. No significant difference was noticed in the dose to the urethra and rectum. All planning goals were met with both the adaptive and rectilinear approach for each plan. Conclusion: The study reveals enhanced coverage of the target when using the adaptive needle adjustments as compared to the rectilinear approach for the analyzed cases. However, the differences in dosimetry did not translate to meaningful clinical outcomes.

  8. Fragmentation of Nimotuzumab for Preparation of 125I-F(ab’)2-Nimotuzumab as a Precursor for Preparing 125I-F(ab’)2-Nimotuzumab-NLS Radiopharmaceutical for Cancer Therapy

    OpenAIRE

    R.D. Haryuni; A. Bahtiar; S. Soenarjo; Y. Harahap; A. Mutalib; M. Ramli; S. Hermanto; C.N. Ardiyatno; V.Y. Susilo; D. Haffid

    2014-01-01

    Nimotuzumab is an anticancer agent which belongs to the inhibitor group of Epidermal Growth Factor Receptor (EGFR). Thismonoclonal antibody has a relatively high molecular weight which slowspenetration on tumor cells, making it less attractive in imaging kinetics and potentially elicits antibodies responses. Therefore, in this study nimotuzumab was fragmented to form a bivalent antibody [F(ab')2] and then labeled with 125I to form 125I-F(ab')2-nimotuzumab which can be used further as a precur...

  9. A Dose–Response Analysis of Biochemical Control Outcomes After {sup 125}I Monotherapy for Patients With Favorable-Risk Prostate Cancer

    Energy Technology Data Exchange (ETDEWEB)

    Shiraishi, Yutaka, E-mail: shiraishi@rad.med.keio.ac.jp [Department of Radiology, Keio University School of Medicine, Tokyo (Japan); Department of Radiology, National Hospital Organization Tokyo Medical Center, Tokyo (Japan); Yorozu, Atsunori [Department of Radiology, National Hospital Organization Tokyo Medical Center, Tokyo (Japan); Ohashi, Toshio [Department of Radiology, Keio University School of Medicine, Tokyo (Japan); Toya, Kazuhito [Department of Radiology, National Hospital Organization Tokyo Medical Center, Tokyo (Japan); Saito, Shiro; Nishiyama, Toru; Yagi, Yasuto [Department of Urology, National Hospital Organization Tokyo Medical Center, Tokyo (Japan); Shigematsu, Naoyuki [Department of Radiology, Keio University School of Medicine, Tokyo (Japan)

    2014-12-01

    Purpose: To define the optimal dose for {sup 125}I prostate implants by correlating postimplantation dosimetry findings with biochemical failure and toxicity. Methods and Materials: Between 2003 and 2009, 683 patients with prostate cancer were treated with {sup 125}I prostate brachytherapy without supplemental external beam radiation therapy and were followed up for a median time of 80 months. Implant dose was defined as the D90 (the minimal dose received by 90% of the prostate) on postoperative day 1 and 1 month after implantation. Therefore, 2 dosimetric variables (day 1 D90 and day 30 D90) were analyzed for each patient. We investigated the dose effects on biochemical control and toxicity. Results: The 7-year biochemical failure-free survival (BFFS) rate for the group overall was 96.4% according to the Phoenix definition. A multivariate analysis found day 1 D90 and day 30 D90 to be the most significant factors affecting BFFS. The cutoff points for day 1 D90 and day 30 D90, calculated from ROC curves, were 163 Gy and 175 Gy, respectively. By use of univariate analysis, various dosimetric cutoff points for day 30 D90 were tested. We found that day 30 D90 cutoff points from 130 to 180 Gy appeared to be good for the entire cohort. Greater D90s were associated with an increase in late genitourinary or gastrointestinal toxicity ≥ grade 2, but the increase was not statistically significant. Conclusions: Improvements in BFFS rates were seen with increasing D90 levels. Day 30 D90 doses of 130 to 180 Gy were found to serve as cutoff levels. For low-risk and low-tier intermediate-risk prostate cancer patients, high prostate D90s, even with doses exceeding 180 Gy, achieve better treatment results and are feasible.

  10. Evaluation of 125I-estradiol radioimmunoassay system with double antibody method

    International Nuclear Information System (INIS)

    Kurano, Akihiko; Nakamura, Genichi; Kusuda, Masahiko; Taki, Ichiro

    1978-01-01

    The basic and clinical evaluation of a new radioimmunoassay (RIA) kit for estradiol (E 2 ) using 125 I-estradiol was performed. This system was double antibody method of RIA with 125 I-labeled E 2 , antiserum against E 2 -6-oxime-BSA and second antibody. The lowest detectable amount was 3.1 pg/tube, the water blank was 3.2 +- 3.15 pg (N=11), and the recovery rate through procedure was 92.6 +- 4.55%. The coefficient of variation was 4.3 - 5.1% for intraassay and the correlation between E 2 values in I-assay and those in II-assay was good (N=30, γ=0.9870, p 3 H-RIA method, there was a high correlation between this method and 3 H-RIA method in E 2 values (N=31, γ=0.9754, p 2 values obtained by this method were slightly higher than those obtained by 3 H-RIA method. Serum E 2 values in normal cycle, short luteal phase, amenorrhea, castrated women, normal men and cases of induced ovulation were measured with this RIA kit, the results were very satisfactory. From these results, it is suggested that this RIA kit can be qualified for clinical application, because this kit is the system without chromatography and many clinical samples can be measured within one day. (auth.)

  11. Autoradiographic localization of (125I-Tyr4)bombesin-binding sites in rat brain

    International Nuclear Information System (INIS)

    Zarbin, M.A.; Kuhar, M.J.; O'Donohue, T.L.; Wolf, S.S.; Moody, T.W.

    1985-01-01

    The binding of ( 125 I-Tyr 4 )bombesin to rat brain slices was investigated. Radiolabeled (Tyr 4 )bombesin bound with high affinity (K/sub d/ . 4 nM) to a single class of sites (B/sub max/ . 130 fmol/mg of protein); the ratio of specific to nonspecific binding was 6/1. Also, pharmacology studies indicated that the C-terminal of bombesin was important for the high affinity binding activity. Autoradiographic studies indicated that the ( 125 I-Tyr4)bombesin-binding sites were discretely distributed in certain gray but not white matter regions of rat brain. Highest grain densities were present in the olfactory bulb and tubercle, nucleus accumbens, suprachiasmatic and periventricular nuclei of the hypothalamus, central medial thalamic nucleus, medial amygdaloid nucleus, hippocampus, dentate gyrus, subiculum, nucleus of the solitary tract, and substantia gelatinosa. Moderate grain densities were present in the parietal cortex, deep layers of the neocortex, rhinal cortex, caudate putamen, stria terminalis, locus ceruleus, parabrachial nucleus, and facial nucleus. Low grain densities were present in the globus pallidus, lateral thalamus, and midbrain. Negligible grain densities were present in the cerebellum, corpus callosum, and all regions treated with 1 microM unlabeled bombesin. The discrete regional distribution of binding suggests that endogenous bombesin-like peptides may function as important regulatory agents in certain brain loci

  12. The influence of temperature on the diffusion of {sup 125}I{sup -} in Beishan granite

    Energy Technology Data Exchange (ETDEWEB)

    Chen, T.; Sun, M.; Li, C.; Tian, W.; Liu, X.; Wang, L.; Wang, X.; Liu, C. [Beijing National Lab. for Molecular Science, Peking Univ., BJ (China)

    2010-07-01

    China has planned to deal with the high-level radioactive wastes (HLW) in the middle of this century with deep geologic disposal method. The release of heat from HLW may cause the rise of temperatures in the surrounding backfilling materials or even the host rock of a repository. This brings about the concerns that the temperature elevation in the host rock may change the diffusion characteristics of key radionuclides and have some unpredictable effects in the performance assessment. In this paper, the influence of temperature on the diffusion of {sup 125}I{sup -} in Beishan Granite is studied by through diffusion method. The effective diffusion coefficients (D{sub e}) of {sup 125}I{sup -} in the granite from 27 to 50 C are obtained and analyzed as a function of temperature. Our result indicated that the relationship between D{sub e} and temperature can be described by the modified Nernst equation, and the formation factors (F{sub f}) of the granite from 27 to 50 C is constant with an average value of 1.03 x 10{sup -4}. (orig.)

  13. Development of a 2-site radioimmunoassay for antithyroglobulin antibodies using 125I-thyroglobulin

    International Nuclear Information System (INIS)

    Leonard, J.P.; Taymans, F.; Beckers, C.

    1977-01-01

    A 2-site radioassay for human antithyroglobulin auto-antibodies has been developed using human thyroglobulin (Tg) labelled with 125 I. The technique is based on (1) the use of polystyrene tubes coated with Tg, (2) the binding of the antibodies to the solid phase Tg, (3) the reaction of the labelled Tg with the insolubilized antibodies. Factors affecting the assay were evaluated including (a) the effect of the temperature, Tg concentration and coating time on the adsorption of Tg, (b) the stability and storage of the solid phase Tg, (c) the variations in temperature, reaction times and incubation volumes, (d) the effect of the serum proteins, (e) the influence of the variations in concentration and specific activity of the labelled Tg. Increasing sensitivity resulted from a prolonged incubation at low temperature, the addition of serum proteins and the use of an appropriate specific activity of 125 I-Tg. Nonspecific radioactive uptake normally averaged 1% or less of the total radioactivity added. The use of Tg coated tubes makes the technique rapid and simple to be operated. The ability of the coated tubes to be stored and the relative insensitivity of the test to fluctuations in the quality of the tracer represent additional advantages in the routine application of the method. (orig.) [de

  14. 125I-labelled botulinum A neurotoxin: pharmacokinetics in cats after intramuscular injection

    International Nuclear Information System (INIS)

    Wiegand, H.; Erdmann, G.; Wellhoener, H.H.

    1976-01-01

    On unilateral injection of sublethal doses of 125 I-botulinum A neurotoxin (BTA) into one gastrocnemius muscle of the cat we found after 48 h: a disto-proximal gradient of radioactivity (RA) hat developed in the sciatic nerve of the injected side. The ventral roots of the spinal cord half segments supplying the injected muscle showed a higher RA than the ventral roots of the contralateral control side. The spinal cord half segments innervating the injected muscle had a RA much higher than the corresponding segments of the contralateral side. However, a small rise of RA was also observed in the contralateral half segments. In histoautoradiographs of the (ligatured) ventral roots the RA was strictly confined to the intraaxonal space of a few nerve fibres. On injection of equal doses of 125 I-BTA into either gastrocnemius muscle we found after 38 h: direct stimulation of only one of the injected muscles caused the RA to reach a higher level in the spinal cord half segments ipsilateral to the stimulated muscle than in the spinal cord half segments of the non-stimulated side. Unilateral stimulation of one gastrocnemius nerve under the influence of gallamine or unilateral antidromic stimulation of the dorsal roots L7, S1 failed to cause a difference in RA between stimulated and non-stimulated side. (orig.) [de

  15. /sup 125/I-labelled botulinum A neurotoxin: pharmacokinetics in cats after intramuscular injection

    Energy Technology Data Exchange (ETDEWEB)

    Wiegand, H; Erdmann, G; Wellhoener, H H [Giessen Univ. (Germany, F.R.). Pharmakologisches Inst.

    1976-01-01

    On unilateral injection of sublethal doses of /sup 125/I-botulinum A neurotoxin (BTA) into one gastrocnemius muscle of the cat we found after 48 h: a disto-proximal gradient of radioactivity (RA) hat developed in the sciatic nerve of the injected side. The ventral roots of the spinal cord half segments supplying the injected muscle showed a higher RA than the ventral roots of the contralateral control side. The spinal cord half segments innervating the injected muscle had a RA much higher than the corresponding segments of the contralateral side. However, a small rise of RA was also observed in the contralateral half segments. In histoautoradiographs of the (ligatured) ventral roots the RA was strictly confined to the intraaxonal space of a few nerve fibres. On injection of equal doses of /sup 125/I-BTA into either gastrocnemius muscle we found after 38 h: direct stimulation of only one of the injected muscles caused the RA to reach a higher level in the spinal cord half segments ipsilateral to the stimulated muscle than in the spinal cord half segments of the non-stimulated side. Unilateral stimulation of one gastrocnemius nerve under the influence of gallamine or unilateral antidromic stimulation of the dorsal roots L7, S1 failed to cause a difference in RA between stimulated and non-stimulated side.

  16. Radioimmunoanalysis of delta-9-THC in blood by means of an 125I tracer

    International Nuclear Information System (INIS)

    Owens, S.M.; McBay, A.J.; Reisner, H.M.

    1982-01-01

    A radioimmunoassay for delta-9-THC in plasma, whole blood, or hemolyzed blood specimens has been presented. Samples and standards were diluted with methanol and centrifuged. An aliquot of the supernatant fluid was incubated with RIA buffer, 125 I-labeled delta-8-THC and rabbit anti-THC serum. Solid phase goat anti-rabbit immunoglobulins were added to separate bound from free THC. After centrifugation the supernatant fluid was aspirated and the radioactivity of the precipitate was counted in a gamma counter. The concentration of THC was calculated from a standard curve using the logit-log transformation of the average counts of duplicate tubes. The assay had several advantages. Methanol dilution gave better results than direct analysis. The 125 I-labeled THC had high specific activity and could be counted in a gamma counter. The immunological separation of antibody-bound THC from free THC was better than separation techniques using ammonium sulfate and activated charcoal. THC was determined in 0.1 ml of sample with a sensitivity of 1.5 ng/ml in plasma and 3.0 ng/ml in hemolyzed blood

  17. Radiation complications and tumor control after 125I plaque brachytherapy for ocular melanoma

    International Nuclear Information System (INIS)

    Jensen, Ashley W.; Petersen, Ivy A.; Kline, Robert W.; Stafford, Scott L.; Schomberg, Paula J.; Robertson, Dennis M.

    2005-01-01

    Purpose: To determine the outcome of 125 I plaque brachytherapy at our institution and identify the risk factors associated with the development of radiation complications, tumor recurrence, and metastasis. Patients and Methods: From 1986 to 2000, 156 patients underwent 125 I episcleral plaque (COMS design) application for the treatment of ocular melanoma. Chart analysis of follow-up ophthalmologic appointments assessed the incidence of ocular side effects after therapy. Statistical analysis assessed outcomes and significant influencing factors. Results: With a median follow-up of 6.2 years, the 5-year overall survival was 83%. The 5-year disease-specific survival was 91%. Initial local control at 5 years was 92%, with 100% ultimate local control after secondary therapy that included 9 enucleations. The risk of metastasis was 10% at 5 years and 27% at 10 years. Vision stayed the same or improved in 25% of patients, and 44% of patients maintained visual acuity better than 20/200. Thirteen percent of patients experienced chronic pain or discomfort in the treated eye. Dose rates to the tumor apex greater than 90 to 100 cGy/h were associated with increased systemic control but worse radiation toxicity. Conclusion: Patients in our series experienced excellent local tumor control. Higher dose rates to the tumor apex were associated with reduced rates of distant metastases but worse ocular function

  18. Plasma kinetics of 125I beta endorphin turnover in lean and obese Zucker rats

    International Nuclear Information System (INIS)

    Rodd, D.; Caston, A.L.; Green, M.H.; Farrell, P.A.

    1990-01-01

    Plasma clearance kinetics for Beta Endorphin (BEP) are not well-defined and no definitive data exist for lean versus obese animals. To determine such kinetic parameters, a bolus of 125 I BEP (1μCi/kg) was infused into awake lean(L) and obese(O) Zucker rats. Arterial blood samples were withdrawn initially at 20 seconds intervals and less frequently as a 3-hour experimental period progressed. Donor rat blood was infused (venous catheter) to replace withdrawn blood. At 180 minutes approximately 10% of the initial dose remained in the plasma. Clearance kinetics for 125 I BEP were analyzed by compartmental analysis. A 3-component equation (i.e., 3 compartment model) provided the best fit for both L and O groups. Plasma transit times were very rapid; however, plasma fractional catabolic rate was low. Plasma mean residence time was similar for both groups (50 minutes) as was recycle time. These data suggest that BEP kinetics are similar in L and O rats, and that this peptide may undergo extensive recycling into and out of the plasma compartment. The identity of the other two compartments requires further investigation

  19. Spark chamber used for the visualization of the 125I labeled thyroid

    International Nuclear Information System (INIS)

    Morucci, Jean-Pierre; Seigneur, Alain; Lansiart, Alain

    1971-03-01

    This spark chamber is a stationary detector used for the visualization of the 125 I labeled thyroid; it is sensitive to X and low energy gamma rays. This device is filled mainly with pressurized xenon (1.5 kg/cm 2 ) and behaves as an X-ray image intensifier: the incident radiation is detected and initiates a spark. The energy dissipated by the spark is reduced and controlled by a double coated anode, while an electronic circuit triggered by the initiation of the spark discharges the detector capacitance. The sparks are recorded on a photographic plate during the examination. X ray optics are used for collimation between the thyroid and the detector. A modulation transfer function was measured for 125 I. Communication theory was used to determine the best way of combining the collimator and spark chamber. This device is being used in the Service Hospitalier Frederic Joliot at Orsay. Its performance is superior to that of conventional scintigraphs. Further applications are envisaged [fr

  20. Radiolabeling of thioguanine with 125I for diagnosis and therapy: in vitro and in vivo evaluation

    International Nuclear Information System (INIS)

    Amin, A.M.; Killa, H.M.; El-Aziz, H.A.

    2010-01-01

    Labeling was carried out by direct iodination of thioguanine (100 μg) with radioiodine in a fast single step at 60 deg C, to produce iodo-6-thioguanine ( 125 I-S6G). Chloramine-T (200 μg) was used as oxidizing agent to oxidize the iodide ion