WorldWideScience

Sample records for security clearance backlog

  1. Nuclear regulation. NRC's security clearance program can be strengthened

    International Nuclear Information System (INIS)

    Fultz, Keith O.; Kruslicky, Mary Ann; Bagnulo, John E.

    1988-12-01

    Because of the national security implications of its programs, the Nuclear Regulatory Commission (NRC) investigates the background of its employees and consultants as well as others to ensure that they are reliable and trustworthy. If the investigation indicates that an employee will not endanger national security, NRC grants a security clearance that allows access to classified information, material, and facilities. NRC also requires periodic checks for some clearance holders to ensure their continued clearance eligibility. The Chairman, Subcommittee on Environment, Energy, and Natural Resources, House Committee on Government Operations, asked GAO to review NRC's personnel security clearance program and assess the procedures that NRC uses to ensure that those who operate nuclear power plants do not pose a threat to the public. The Atomic Energy Act of 1954 requires NRC to conduct background investigations of its employees and consultants as well as others who have access to classified information, material, or facilities. To do this, NRC established a personnel security clearance program. Under NRC policies, a security clearance is granted after the Office of Personnel Management (OPM) or the Federal Bureau of Investigation checks the background of those applying for an NRC clearance. NRC also periodically reassesses the integrity of those holding the highest level clearance. NRC employees, consultants, contractors, and licensees as well as other federal employees hold approximately 10,600 NRC clearances. NRC does not grant clearances to commercial nuclear utility employees unless they require access to classified information or special nuclear material. However, the utilities have voluntarily established screening programs to ensure that their employees do not pose a threat to nuclear plants. NRC faces a dilemma when it hires new employees. Although its policy calls for new hires to be cleared before they start work, the security clearance process takes so long

  2. 10 CFR 2.905 - Access to restricted data and national security information for parties; security clearances.

    Science.gov (United States)

    2010-01-01

    ... information for parties; security clearances. 2.905 Section 2.905 Energy NUCLEAR REGULATORY COMMISSION RULES... to Adjudicatory Proceedings Involving Restricted Data and/or National Security Information § 2.905 Access to restricted data and national security information for parties; security clearances. (a) Access...

  3. Security Clearances and the Protection of National Security Information: Law and Procedures

    National Research Council Canada - National Science Library

    Cohen, Sheldon

    2000-01-01

    ... designed to protect National Security information. The report provides an authoritative compendium for lawyers, security officers and for managers of corporations who must deal with the legal and procedural aspects of security clearances...

  4. 10 CFR 95.21 - Withdrawal of requests for facility security clearance.

    Science.gov (United States)

    2010-01-01

    ... 10 Energy 2 2010-01-01 2010-01-01 false Withdrawal of requests for facility security clearance. 95.21 Section 95.21 Energy NUCLEAR REGULATORY COMMISSION (CONTINUED) FACILITY SECURITY CLEARANCE AND SAFEGUARDING OF NATIONAL SECURITY INFORMATION AND RESTRICTED DATA Physical Security § 95.21 Withdrawal of...

  5. Nuclear security. DOE actions to improve the personnel clearance program

    International Nuclear Information System (INIS)

    Fultz, Keith O.; Bannerman, Carl J.; Daniel, Beverly A.

    1988-11-01

    The status of the Department of Energy's (DOE) implementation of recommendations in our two reports on DOE's personnel security clearance program was determined. The recommendations were aimed at improving the timeliness, accuracy, and efficiency of personnel security clearance decisions. Specifically, the objective was to determine and report on steps DOE is taking to implement these recommendations. In summary, it was found that DOE has either initiated action or is studying ways to address all the recommendations, but none of the recommendations have been completely implemented. The effectiveness of the DOE actions will depend, in part, on the adequacy of its internal control system for overseeing and evaluating program operations. DOE's personnel security clearance program is intended to provide reasonable assurance that personnel with access to classified information and materials are trustworthy. The Department requests that the Office of Personnel Management or the Federal Bureau of Investigation collect personal data on each person who requires such access to do his or her job. Based on these background investigations, DOE officials authorize individuals whose personal histories indicate that they are trustworthy to have access to classified information, secured facilities, and controlled materials as needed to perform their jobs. DOE has five types of these authorizations or personnel security clearances and must update information on personnel holding each type at 5-year intervals to confirm their continuing reliability. The five types are based on the types of security interests to which the person needs access, e.g., persons needing nuclear weapons-related data must have a Q clearance, and persons with a top secret clearance can have access to national security data classified as top secret

  6. 2015 Annual Report on Security Clearance Determinations

    Science.gov (United States)

    2016-06-28

    only have delegated investigative authority over their civilian employee population and therefore, can only report the overall timeliness for that...completed or pending security clearance determinations for government employees and contractors during the preceding fiscal year that have taken longer...Clearance Determinations to Congress. The IAA directs this report to include the number of United States Government (USG) employees who held a

  7. 78 FR 48076 - Facility Security Clearance and Safeguarding of National Security Information and Restricted Data

    Science.gov (United States)

    2013-08-07

    ...-2011-0268] RIN 3150-AJ07 Facility Security Clearance and Safeguarding of National Security Information..., Classified National Security Information. The rule would allow licensees flexibility in determining the means... licensee security education and training programs and enhances the protection of classified information...

  8. 78 FR 48037 - Facility Security Clearance and Safeguarding of National Security Information and Restricted Data

    Science.gov (United States)

    2013-08-07

    ... Clearance and Safeguarding of National Security Information and Restricted Data AGENCY: Nuclear Regulatory... the objectives of Executive Order 13526, Classified National Security Information. The rule allows... signed Executive Order 13526, Classified National Security Information, which was published in the...

  9. 78 FR 69286 - Facility Security Clearance and Safeguarding of National Security Information and Restricted Data

    Science.gov (United States)

    2013-11-19

    ... Clearance and Safeguarding of National Security Information and Restricted Data AGENCY: Nuclear Regulatory... Executive Order 13526, Classified National Security Information. In addition, this direct final rule allowed... licensees (or their designees) to conduct classified [[Page 69287

  10. 76 FR 45645 - 10-Day Notice of Proposed Information Collection: Technology Security/Clearance Plans, Screening...

    Science.gov (United States)

    2011-07-29

    ...: Technology Security/Clearance Plans, Screening Records, and Non-Disclosure Agreements ACTION: Notice of... Information Collection: Technology Security/ Clearance Plans, Screening Records, and Non-Disclosure Agreements...: None. Respondents: Business and Nonprofit Organizations, Foreign Governments. Estimated Number of...

  11. 28 CFR 16.132 - Exemption of Department of Justice System-Personnel Investigation and Security Clearance Records...

    Science.gov (United States)

    2010-07-01

    ... System—Personnel Investigation and Security Clearance Records for the Department of Justice (DOJ), DOJ... 28 Judicial Administration 1 2010-07-01 2010-07-01 false Exemption of Department of Justice System-Personnel Investigation and Security Clearance Records for the Department of Justice (DOJ), DOJ-006. 16.132...

  12. Method and computer program product for maintenance and modernization backlogging

    Science.gov (United States)

    Mattimore, Bernard G; Reynolds, Paul E; Farrell, Jill M

    2013-02-19

    According to one embodiment, a computer program product for determining future facility conditions includes a computer readable medium having computer readable program code stored therein. The computer readable program code includes computer readable program code for calculating a time period specific maintenance cost, for calculating a time period specific modernization factor, and for calculating a time period specific backlog factor. Future facility conditions equal the time period specific maintenance cost plus the time period specific modernization factor plus the time period specific backlog factor. In another embodiment, a computer-implemented method for calculating future facility conditions includes calculating a time period specific maintenance cost, calculating a time period specific modernization factor, and calculating a time period specific backlog factor. Future facility conditions equal the time period specific maintenance cost plus the time period specific modernization factor plus the time period specific backlog factor. Other embodiments are also presented.

  13. Solid Waste Information Tracking System (SWITS), Backlog Waste Modifications, Software Requirements Specification (SRS)

    International Nuclear Information System (INIS)

    Clark, R.E.

    1995-01-01

    Purpose of this document is to define the system requirements necessary to improve computer support for the WHC backlog waste business process through enhancements to the backlog waste function of the SWITS system. This SRS document covers enhancements to the SWITS system to support changes to the existing Backlog Waste screens including new data elements, label changes, and new pop-up screens. The pop-ups will allow the user to flag the processes that a waste container must have performed on it, and will provide history tracking of changes to data. A new screen will also be provided allowing Acceptable Services to perform mass updates to specific data in Backlog Waste table. The SWITS Backlog Waste enhancements in this document will support the project goals in WHC-SD-WM-003 and its Revision 1 (Radioactive Solid Waste Tracking System Conceptual Definition) for the control, tracing, and inventory management of waste as the packages are generated and moved through final disposal (cradle-to-grave)

  14. Tank farms backlog soil sample and analysis results supporting a contained-in determination

    Energy Technology Data Exchange (ETDEWEB)

    Jackson, C.L., Fluor Daniel Hanford

    1997-02-27

    Soil waste is generated from Tank Farms and associated Tank Farms facilities operations. The soil is a mixed waste because it is an environmental media which contains tank waste, a listed mixed waste. The soil is designated with the listed waste codes (FOO1 through F005) which have been applied to all tank wastes. The scope of this report includes Tank Farms soil managed under the Backlog program. The Backlog Tank Farm soil in storage consists of drums and 5 boxes (originally 828 drums). The Backlog Waste Program dealt with 2276 containers of solid waste generated by Tank Farms operations during the time period from 1989 through early 1993. The containers were mismanaged by being left in the field for an extended period of time without being placed into permitted storage. As a corrective action for this situation, these containers were placed in interim storage at the Central Waste Complex (CWC) pending additional characterization. The Backlog Waste Analysis Plan (BWAP) (RL 1993) was written to define how Backlog wastes would be evaluated for proper designation and storage. The BWAP was approved in August 1993 and all work required by the BWAP was completed by July 1994. This document presents results of testing performed in 1992 & 1996 that supports the attainment of a Contained-In Determination for Tank Farm Backlog soils. The analytical data contained in this report is evaluated against a prescribed decision rule. If the decision rule is satisfied then the Washington State Department of ecology (Ecology) may grant a Contained-In Determination. A Contained-In Determination for disposal to an unlined burial trench will be requested from Ecology . The decision rule and testing requirements provided by Ecology are described in the Tank Farms Backlog Soil Sample Analysis Plan (SAP) (WHC 1996).

  15. Security Clearance Tracking System

    Data.gov (United States)

    National Archives and Records Administration — SCTS supports the adjudication process of private background investigations and clearances for potential employees, contractors, interns and student workers.

  16. Optimal pricing and replenishment policies for instantaneous deteriorating items with backlogging and trade credit under inflation

    Science.gov (United States)

    Sundara Rajan, R.; Uthayakumar, R.

    2017-12-01

    In this paper we develop an economic order quantity model to investigate the optimal replenishment policies for instantaneous deteriorating items under inflation and trade credit. Demand rate is a linear function of selling price and decreases negative exponentially with time over a finite planning horizon. Shortages are allowed and partially backlogged. Under these conditions, we model the retailer's inventory system as a profit maximization problem to determine the optimal selling price, optimal order quantity and optimal replenishment time. An easy-to-use algorithm is developed to determine the optimal replenishment policies for the retailer. We also provide optimal present value of profit when shortages are completely backlogged as a special case. Numerical examples are presented to illustrate the algorithm provided to obtain optimal profit. And we also obtain managerial implications from numerical examples to substantiate our model. The results show that there is an improvement in total profit from complete backlogging rather than the items being partially backlogged.

  17. Setting ART initiation targets in response to changing guidelines: The importance of addressing both steady-state and backlog.

    Science.gov (United States)

    Martin, Catherine; Naidoo, Nicolette P; Venter, W D Francois; Jaffer, Ambereen; Barker, Pierre M

    2014-05-12

    Target setting is useful in planning, assessing and improving antiretroviral treatment (ART) programmes. In the past 4 years, the ART initiation environment has been transformed due to the change in eligibility criteria (starting ART at a CD4+ count ART. To describe and illustrate the use of a target-setting model for estimating district-based targets in the era of an expanding ART programme and changing CD4+ count thresholds for ART initiation. Using previously described models and data for annual new HIV infections, we estimated both steady-state need for ART initiation and backlog in a North West Province district, accounting for the shift in eligibility. Comparison of actual v. targeted ART initiations was undertaken. The change in CD4+ count threshold adds a once-off group of newly eligible patients to the pool requiring ART - the backlog. The steady-state remains unchanged as it is determined by the annual rate of new HIV infections in previous years. The steady-state need for the district was 639 initiations/month, and the backlog was ~15,388 patients. After the shift in eligibility in September 2011, the steady-state target was exceeded over several months with some backlog addressed. Of the total backlog for this district, 72% remains to be cleared. South Africa has two pools of patients who need ART: the steady-state of HIV-infected patients entering the programme each year, determined by historical infection rates; and the backlog created by the shift in eligibility. The healthcare system needs to build long- term capacity to meet the steady-state need for ART and additional capacity to address the backlog.

  18. Optimal control of a one product recovery system with backlogging

    NARCIS (Netherlands)

    Kiesmüller, G.P.; Minner, S.; Kleber, R.

    2000-01-01

    In this paper a product recovery system for one product is investigated. The system contains one inventory for returned and recoverable items and one for serviceable items. Demands are satisfied from serviceable inventory where backlogging of demands is allowed. In addition, there is the possibility

  19. Analysis of traffic signal work backlog in Louisiana : technical assistance report.

    Science.gov (United States)

    1995-07-01

    A review of Traffic Services' traffic signal work records reveals the source of the backlog. During the 1980's, the department experienced personnel cutbacks and hiring freezes that caused the number of field personnel to drop from 40 to 24. Simultan...

  20. [How much does the backlog on drug patents cost for health in Brazil?

    Science.gov (United States)

    Jannuzzi, Anna Haydée Lanzillotti; Vasconcellos, Alexandre Guimarães

    2017-08-21

    The backlog in processing patent applications in Brazil has persisted since the enactment of Law 9,279/1996, when the country resumed granting patents on drugs. The agencies responsible for granting such patents, namely the Brazilian National Patent and Trademark Office (INPI) and the Brazilian National Health Surveillance Agency (Anvisa) cite technical and administrative reasons for the backlog. However, little research has focused on the economic impacts for health due to the inefficiency of the Brazilian patent system. The current study thus proposes a methodology to estimate the extent to which government procurement of medicines is burdened by the backlog in drug patent applications. According to the results, a total of more than BRL 14 million (USD 4.5 million) is spent unnecessarily per year by the Federal Government on just one antiretroviral drug due to the extension of the respective patent's life. Measures to resolve this situation are urgently needed in the three branches of government. These include hiring more staff for the INPI, analysis of bills of law under review in the two houses of the Brazilian Congress to amend the Industrial Property Law, and ruling on direct class action claims of unconstitutionality to suppress the legal mechanisms that allow extending the life of patents.

  1. A framework for an inventory model for deteriorating items with expiration under trapezoidal-type demand and partial backlogging

    Directory of Open Access Journals (Sweden)

    Kunal T. Shukla

    2016-09-01

    Full Text Available Background: As in the case of deteriorating items, expiration plays a major role in inventory management, a generalized approach is studied based on an inventory model for deteriorating items with expiration dates. Methods: In this paper, the demand rate during the cycle time is assumed to be trapezoidal. Shortages are allowed and partially backlogged. An inventory replenishment strategy is formulated for trapezoidal demand rates and backlogging rates in general for retailers; with the support of fundamental concepts of calculus. Results: The method is illustrated with the support of numerical examples along with sensitivity analysis with respect to major parameters. Conclusion: This generalized approach provides a platform to develop a strategy using different demand functions and backlogging rates.

  2. 32 CFR 154.16 - Security clearance.

    Science.gov (United States)

    2010-07-01

    ... part. The Director, Washington Headquarters Services (WHS) will initiate the required investigation... clearance, as appropriate. The Assistant Secretary of Defense (Legislative Affairs) will be notified by WHS...

  3. The backlog issue in patents: A look at the European case

    NARCIS (Netherlands)

    Rodriguez, V.

    2010-01-01

    Backlogs can be caused by an increase in the number of patent applications and patent size. A large number of patents granted could be explained by patent examiners' bonuses, legal and cultural contexts, claim forms, the geographical origin of patents, a firm's experience in patenting, the number of

  4. Personnel Security Investigations -

    Data.gov (United States)

    Department of Transportation — This data set contains the types of background investigations, decisions, level of security clearance, date of security clearance training, and credentials issued to...

  5. An economic order quantity model with nonlinear holding cost, partial backlogging and ramp-type demand

    Science.gov (United States)

    San-José, Luis A.; Sicilia, Joaquín; González-de-la-Rosa, Manuel; Febles-Acosta, Jaime

    2018-07-01

    In this article, a deterministic inventory model with a ramp-type demand depending on price and time is developed. The cumulative holding cost is assumed to be a nonlinear function of time. Shortages are allowed and are partially backlogged. Thus, the fraction of backlogged demand depends on the waiting time and on the stock-out period. The aim is to maximize the total profit per unit time. To do this, a procedure that determines the economic lot size, the optimal inventory cycle and the maximum profit is presented. The inventory system studied here extends diverse inventory models proposed in the literature. Finally, some numerical examples are provided to illustrate the theoretical results previously propounded.

  6. Security guide for subcontractors

    Energy Technology Data Exchange (ETDEWEB)

    Adams, R.C.

    1991-01-01

    This security guide of the Department of Energy covers contractor and subcontractor access to DOE and Mound facilities. The topics of the security guide include responsibilities, physical barriers, personnel identification system, personnel and vehicular access controls, classified document control, protecting classified matter in use, storing classified matter repository combinations, violations, security education clearance terminations, security infractions, classified information nondisclosure agreement, personnel security clearances, visitor control, travel to communist-controlled or sensitive countries, shipment security, and surreptitious listening devices.

  7. [Are investment activity and backlog in investments risks for university medicine in Germany?].

    Science.gov (United States)

    Amann, I; Heyder, R; Strehl, R

    2009-08-01

    University medicine in Germany requires significantly higher funding and investment because its tasks not only include health care but also research and teaching. However, over recent decades less and less funding compared to the development of the turnover has been available. This trend is due to decreasing public funding. The diminishing funding has caused a major backlog of investment at German university hospitals. The first part of the article summarizes the investments policies at university hospitals and other hospitals. The second part describes the investment needs in university medicine and exposes risk factors for research, education and health care due to the process of investment planning and realization. Goal-oriented solutions are shown to facilitate investments. The third part discusses several risks caused by insufficient investments in university medicine. There are special risks for research, teaching, and the capacity for innovation in university medicine besides economical and medical risks. Some policies and financial strategies to overcome the backlog in investments are presented. After a summary, the article concludes with some practical examples of further measures to ensure sustainable funding.

  8. DOD PERSONNEL CLEARANCES: Additional OMB Actions Are Needed to Improve the Security Clearance Process

    National Research Council Canada - National Science Library

    2006-01-01

    Our independent analysis of timeliness data showed that industry personnel contracted to work for the federal government waited more than one year on average to receive top secret clearances, longer...

  9. Optimal economic order quantity for buyer-distributor-vendor supply chain with backlogging derived without derivatives

    Science.gov (United States)

    Teng, Jinn-Tsair; Cárdenas-Barrón, Leopoldo Eduardo; Lou, Kuo-Ren; Wee, Hui Ming

    2013-05-01

    In this article, we first complement an inappropriate mathematical error on the total cost in the previously published paper by Chung and Wee [2007, 'Optimal the Economic Lot Size of a Three-stage Supply Chain With Backlogging Derived Without Derivatives', European Journal of Operational Research, 183, 933-943] related to buyer-distributor-vendor three-stage supply chain with backlogging derived without derivatives. Then, an arithmetic-geometric inequality method is proposed not only to simplify the algebraic method of completing prefect squares, but also to complement their shortcomings. In addition, we provide a closed-form solution to integral number of deliveries for the distributor and the vendor without using complex derivatives. Furthermore, our method can solve many cases in which their method cannot, because they did not consider that a squared root of a negative number does not exist. Finally, we use some numerical examples to show that our proposed optimal solution is cheaper to operate than theirs.

  10. Security Investigation Database (SID)

    Data.gov (United States)

    US Agency for International Development — Security Investigation & Personnel Security Clearance - COTS personnel security application in a USAID virtualized environement that can support USAID's business...

  11. Finite horizon EOQ model for non-instantaneous deteriorating items with price and advertisement dependent demand and partial backlogging under inflation

    Science.gov (United States)

    Palanivel, M.; Uthayakumar, R.

    2015-07-01

    This paper deals with an economic order quantity (EOQ) model for non-instantaneous deteriorating items with price and advertisement dependent demand pattern under the effect of inflation and time value of money over a finite planning horizon. In this model, shortages are allowed and partially backlogged. The backlogging rate is dependent on the waiting time for the next replenishment. This paper aids the retailer in minimising the total inventory cost by finding the optimal interval and the optimal order quantity. An algorithm is designed to find the optimum solution of the proposed model. Numerical examples are given to demonstrate the results. Also, the effect of changes in the different parameters on the optimal total cost is graphically presented and the implications are discussed in detail.

  12. Fuzzy inventory model for deteriorating items, with time depended demand, shortages, and fully backlogging

    OpenAIRE

    Wasim Akram Mandal; Sahidul Islam

    2016-01-01

    In this paper analyzes fuzzy inventory system for deterioration item with time depended demand. Shortages are allowed under fully backlogged. Fixed cost, deterioration cost, shortages cost, holding cost are the cost considered in this model. Fuzziness is applying by allowing the cost components (holding cost, deterioration, shortage cost, holding cost, etc). In fuzzy environment it considered all required parameter to be triangular fuzzy numbers. One numerical solution of the model is obtaine...

  13. Privacy and Security: A Bibliography.

    Science.gov (United States)

    Computer and Business Equipment Manufacturers Association, Washington, DC.

    Compiled at random from many sources, this bibliography attempts to cite as many publications concerning privacy and security as are available. The entries are organized under seven headings: (1) systems security, technical security, clearance of personnel, (2) corporate physical security, (3) administrative security, (4) miscellaneous--privacy…

  14. Improving Mental Health Reporting Practices in Between Personnel Security Investigations

    Science.gov (United States)

    2017-06-01

    derogatory information, unfavorable administrative actions, and adverse actions to the appropriate personnel security, human resources , and...national security clearance? What type of clearances do people typically have (e.g., Secret, Top Secret, TS/SCI, SAP , etc.)? (2) Does [the

  15. 22 CFR 8.7 - Security.

    Science.gov (United States)

    2010-04-01

    ... 22 Foreign Relations 1 2010-04-01 2010-04-01 false Security. 8.7 Section 8.7 Foreign Relations DEPARTMENT OF STATE GENERAL ADVISORY COMMITTEE MANAGEMENT § 8.7 Security. (a) All officers and members of a committee must have a security clearance for the subject matter level of security at which the committee...

  16. An EOQ model for weibull distribution deterioration with time-dependent cubic demand and backlogging

    Science.gov (United States)

    Santhi, G.; Karthikeyan, K.

    2017-11-01

    In this article we introduce an economic order quantity model with weibull deterioration and time dependent cubic demand rate where holding costs as a linear function of time. Shortages are allowed in the inventory system are partially and fully backlogging. The objective of this model is to minimize the total inventory cost by using the optimal order quantity and the cycle length. The proposed model is illustrated by numerical examples and the sensitivity analysis is performed to study the effect of changes in parameters on the optimum solutions.

  17. 77 FR 44641 - Critical Infrastructure Private Sector Clearance Program Request

    Science.gov (United States)

    2012-07-30

    .... DHS Sector Specialists or Protective Security Advisors email the form to the individual who then... clearance request form is signed by both the Federal official who nominated the applicant and the Assistant...

  18. Areva At December 31, 2010: Revenue rises to euros 9.104 bn: + 6.7% Backlog rises to euros 44.2 bn: + 2.0%

    International Nuclear Information System (INIS)

    2011-01-01

    In 2010, AREVA's consolidated revenue rose 6.7% to 9.104 billion euros (+ 5.1% growth like-for-like) compared with 2009. The Mining-Front End Business Group and the Reactors and Services Business Group were the leading growth engines, with revenue growth of 6.7% and 8.9% respectively. Foreign exchange had a positive impact of 141 million euros and the scope of consolidation remained stable over the period. Fourth quarter 2010 revenue totaled 2.936 billion euros, an increase of 7.7% (+4.8% like-for-like) compared with the fourth quarter of 2009, due in particular to 18.1% growth in the Mining-Front End BG. Foreign exchange had an impact of 58 million euros over the period. The group's backlog came to 44.2 billion euros at December 31, 2010, up 2.0% in relation to December 31, 2009. The backlog grew in the Mining-Front End and Renewable Energies BGs. Installed Base Business operations held up well, replenishing the backlog for the Reactors and Services BG. The agreement with the Indian utility NPCIL concerning the construction of two EPR TM reactors and fuel cycle supply for 25 years was not recorded in the backlog at December 31, 2010. The change in the Back End BG's backlog reflects the implementation of contracts signed in previous years. Nearly one billion euros in letters of intent signed in 2010 with US utilities corresponding to pre-sold production from the future enrichment plant were not included in the Mining-Front End BG's backlog. The backlog of the Mining-Front End BG came to 28.902 billion euros at December 31, 2010, up 4% compared with the end of 2009. Contracts won in 2010 include: - the 10-year uranium supply contract with CGNPC for approximately 3.5 billion dollars; - several other multi-year contracts signed in the front end of the cycle with US and Asian utilities. For the full year of 2010, the Mining-Front End BG reported revenue of 3.704 billion euros, an increase of 6.7% on a reported basis and of 4.2% LFL. Foreign exchange had a positive

  19. 14 CFR 1260.31 - National security.

    Science.gov (United States)

    2010-01-01

    ... 14 Aeronautics and Space 5 2010-01-01 2010-01-01 false National security. 1260.31 Section 1260.31... Provisions § 1260.31 National security. National Security October 2000 Normally, NASA grants do not involve... who will have access to the information must obtain the appropriate security clearance in advance of...

  20. Replenishment policy for Entropic Order Quantity (EnOQ model with two component demand and partial back-logging under inflation

    Directory of Open Access Journals (Sweden)

    Bhanupriya Dash

    2017-09-01

    Full Text Available Background: Replenishment policy for entropic order quantity model with two component demand and partial backlogging under inflation is an important subject in the stock management. Methods: In this paper an inventory model for  non-instantaneous  deteriorating items with stock dependant consumption rate and partial back logged in addition the effect of inflection and time value of money on replacement policy with zero lead time consider was developed. Profit maximization model is formulated by considering the effects of partial backlogging under inflation with cash discounts. Further numerical example presented to evaluate the relative performance between the entropic order quantity and EOQ models separately. Numerical example is present to demonstrate the developed model and to illustrate the procedure. Lingo 13.0 version software used to derive optimal order quantity and total cost of inventory. Finally sensitivity analysis of the optimal solution with respect to different parameters of the system carried out. Results and conclusions: The obtained inventory model is very useful in retail business. This model can extend to total backorder.

  1. USCIS Backlog Elimination

    Data.gov (United States)

    Department of Homeland Security — USCIS is streamlining the way immigration benefits are delivered. By working smarter and eliminating redundancies, USCIS is bringing a business model to government....

  2. 10 CFR 95.19 - Changes to security practices and procedures.

    Science.gov (United States)

    2010-01-01

    ... 10 Energy 2 2010-01-01 2010-01-01 false Changes to security practices and procedures. 95.19 Section 95.19 Energy NUCLEAR REGULATORY COMMISSION (CONTINUED) FACILITY SECURITY CLEARANCE AND..., also to the Director, Division of Security Operations, Office of Nuclear Security and Incident Response...

  3. Lung mucociliary clearance

    International Nuclear Information System (INIS)

    Mortensen, J.; Lange, P.; Nyboe, J.; Groth, S.

    1994-01-01

    The aim of this study was to establish reference values for mucociliary clearance and mucociliary clearance reserve capacity as determined by β 2 -adrenergic agonist-induced increase in mucociliary clearance. We studied 62 healthy females (n=33) and males (n=29). Their ages ranged evenly between 18 and 84 years. Fifty-three of the subjects were life-long non-smokers, while nine were ex-smokers. Multiple linear regression analyses showed that mucociliary clearance was significantly faster when the radioaerosol was deposited in the central airways than when it was deposited in the peripheral airways, and faster in life-long non-smokers than in ex-smokers. There was no influence of age, and no convincing association with sex. The variation was less within than between subjects. Mean mucociliary clearance reserve capacity was 21.3% (SD: 10.0%, P 2 agonist-induced increase in lung mucociliary clearance was significantly larger (P<0.05) than the stimulation which has previously been reported in patients with asthma, bronchiectasis or cystic fibrosis. The signal-to-noise ratio of the mucociliary clearance reserve capacity in relation to measurement of baseline mucociliary clearance indicates that measurement of mucociliary clearance reserve capacity may be a more efficient means of distinguishing between ''normal'' and ''abnormal'' mucociliary clearance than single measurement of baseline mucociliary clearance. (orig.)

  4. New technologies and emerging threats: personnel security adjudicative guidelines in the age of social networking

    OpenAIRE

    Festa, James P.

    2012-01-01

    Approved for public release; distribution is unlimited Publicized incidents involving espionage or violence by government employees with security clearances have raised concern for the personnel security community. The guidelines used to adjudicate security clearances were last updated in 2005; since that time, significant technological developments, especially in social media and communications, have emerged. This thesis developed a comprehensive list of current Internet behaviors, and us...

  5. Isotope determinations of renal clearance equivalent with physiological clearance measurements

    International Nuclear Information System (INIS)

    Junges, R.

    1983-01-01

    The concept of renal clearance in nuclear medicine describes the tubular secretion and glomerular filtration of a substance being removed from the blood plasma. The concept of clearance as used physiologically is rather wider and includes consideration of the outflow of the substances remained back in the kidneys. The present paper discusses clearance measurements as seen from a thermodynamic point of view, in which isotope clearances become equivalent with the physiological concept of clearance. In addition, it is possible to quantify each single step of the excretory function of each kidney separately. (orig.) [de

  6. 76 FR 63680 - Public Roundtable on Execution, Clearance and Settlement of Microcap Securities

    Science.gov (United States)

    2011-10-13

    ... clearance and settlement process, potential regulatory changes impacting the Over-The-Counter markets, and Anti-Money Laundering concerns specific to microcap issuers. DATES: The roundtable discussion will be...

  7. Comparison of the endogenous creatinine clearance, the creatinin clearance calculated without urine collection and the isotope clearance

    International Nuclear Information System (INIS)

    Mohacsi, Gabor; Lang, Jenoe; Csernay, Laszlo; Sonkodi, Sandor; Orvostudomanyi Egyetem, Szeged

    1987-01-01

    Observations are reported relating to the endogenous creatinine clearance, the Tc-99m-EDTA-complex clearance and the creatinine clearance estimated via a selected mathematical formula, with special regard to the problems of renal insufficiency and the nephrotic syndrome. The activity applied was in the range of 3.7-7.4 MBq. It was observed that measurement of the isotope clearance can also be applied to determine the endogeneous creatinine clearance in otherwise less suitable patients. A reliable result is obtained even if the renal function is restricted, but the accuracy of the method may be reduced in nephrotic syndrome cases. (author) 24 refs

  8. Creatinine clearance test

    Science.gov (United States)

    Serum creatinine clearance; Kidney function - creatinine clearance; Renal function - creatinine clearance ... Creatinine is a chemical waste product of creatine. Creatine is a chemical the body makes to supply ...

  9. 10 CFR 95.49 - Security of automatic data processing (ADP) systems.

    Science.gov (United States)

    2010-01-01

    ... 10 Energy 2 2010-01-01 2010-01-01 false Security of automatic data processing (ADP) systems. 95.49 Section 95.49 Energy NUCLEAR REGULATORY COMMISSION (CONTINUED) FACILITY SECURITY CLEARANCE AND SAFEGUARDING OF NATIONAL SECURITY INFORMATION AND RESTRICTED DATA Control of Information § 95.49 Security of...

  10. Periodic Continuing Disability Review Case Backlog

    Data.gov (United States)

    Social Security Administration — The Social Security Administration (SSA) conducts periodic CDRs to ensure that only those beneficiaries who remain disabled continue to receive monthly benefits. The...

  11. Determining optimal selling price and lot size with process reliability and partial backlogging considerations

    Science.gov (United States)

    Hsieh, Tsu-Pang; Cheng, Mei-Chuan; Dye, Chung-Yuan; Ouyang, Liang-Yuh

    2011-01-01

    In this article, we extend the classical economic production quantity (EPQ) model by proposing imperfect production processes and quality-dependent unit production cost. The demand rate is described by any convex decreasing function of the selling price. In addition, we allow for shortages and a time-proportional backlogging rate. For any given selling price, we first prove that the optimal production schedule not only exists but also is unique. Next, we show that the total profit per unit time is a concave function of price when the production schedule is given. We then provide a simple algorithm to find the optimal selling price and production schedule for the proposed model. Finally, we use a couple of numerical examples to illustrate the algorithm and conclude this article with suggestions for possible future research.

  12. [51Cr]EDTA plasma clearance and endogenous creatinine clearance in advanced renal insufficiency

    International Nuclear Information System (INIS)

    Svendsen, U.G.; Munck, O.; Czartoryski, A.; Stafanger, G.

    1978-01-01

    Comparison of [ 51 Cr]EDTA plasma clearance corrected for extrarenal elimination with 24 h endogenous creatinine clearance in patients with advanced renal failure showed that the corrected [ 51 Cr]EDTA clearance was lower than creatinine clearance, and thus might be a better approximation to the glomerular filtration rate in uraemic patients. The corrections cannot be used on [ 51 Cr]EDTA clearance values below the mean extrarenal clearance, averaging 3.7 ml/min. (Auth.)

  13. Security guide for subcontractors

    Energy Technology Data Exchange (ETDEWEB)

    Adams, R.C.

    1993-06-01

    This guide is provided to aid in the achievement of security objectives in the Department of Energy (DOE) contractor/subcontractor program. The objectives of security are to protect information that, if released, would endanger the common defense and security of the nation and to safeguard plants and installations of the DOE and its contractors to prevent the interruption of research and production programs. The security objective and means of achieving the objective are described. Specific security measures discussed in this guide include physical barriers, personnel identification systems, personnel and vehicular access control, classified document control, protection of classified matter in use, storing classified matter, and repository combinations. Means of dealing with security violations and security infractions are described. Maintenance of a security education program is discussed. Also discussed are methods of handling clearance terminations, visitor control, travel to sensitive countries, and shipment security. The Technical Surveillance Countermeasures Program (TSCM), the Computer Security Program, and the Operations Security Plan (OPSEC) are examined.

  14. Security Modeling on the Supply Chain Networks

    Directory of Open Access Journals (Sweden)

    Marn-Ling Shing

    2007-10-01

    Full Text Available In order to keep the price down, a purchaser sends out the request for quotation to a group of suppliers in a supply chain network. The purchaser will then choose a supplier with the best combination of price and quality. A potential supplier will try to collect the related information about other suppliers so he/she can offer the best bid to the purchaser. Therefore, confidentiality becomes an important consideration for the design of a supply chain network. Chen et al. have proposed the application of the Bell-LaPadula model in the design of a secured supply chain network. In the Bell-LaPadula model, a subject can be in one of different security clearances and an object can be in one of various security classifications. All the possible combinations of (Security Clearance, Classification pair in the Bell-LaPadula model can be thought as different states in the Markov Chain model. This paper extends the work done by Chen et al., provides more details on the Markov Chain model and illustrates how to use it to monitor the security state transition in the supply chain network.

  15. Mucociliary clearance

    DEFF Research Database (Denmark)

    Munkholm, Mathias; Mortensen, Jann

    2014-01-01

    Mucociliary clearance has long been known to be a significant innate defence mechanism against inhaled microbes and irritants. Important knowledge has been gathered regarding the anatomy and physiology of this system, and in recent years, extensive studies of the pathophysiology related to lung...... pharmacological interventions on clearance rate, to study the importance of defective mucus clearance in different lung diseases or as a diagnostic tool in the work-up of patients with recurrent airway diseases. The aim of this review is to provide an overview of the anatomy, physiology, pathophysiology...

  16. Areva excellent business volume: backlog as of december 31, 2008: + 21.1% to 48.2 billion euros. 2008 revenue: + 10.4% to 13.2 billion euros

    International Nuclear Information System (INIS)

    2009-01-01

    AREVA's backlog stood at 48.2 billion euros as of December 31, 2008, for 21.1% growth year-on-year, including 21.8% growth in Nuclear and 16.5% growth in Transmission and Distribution. The Nuclear backlog came to 42.5 billion euros at December 31, 2008. The Transmission and Distribution backlog came to 5.7 billion euros at year-end. The group recognized revenue of 13.2 billion euros in 2008, for year-on-year growth of 10.4% (+9.8% like-for-like). Revenue outside France was up 10.5% to 9.5 billion euros, representing 72% of total revenue. Revenue was up 6.5% in the Nuclear businesses (up 6.3% LFL), with strong performance in the Reactors and Services division (+10.9% LFL) and the Front End division (+7.2% LFL). The Transmission and Distribution division recorded growth of 17% (+15.8% LFL). Revenue for the fourth quarter of 2008 rose to 4.1 billion euros, up 5.2% (+1.6% LFL) from that of the fourth quarter of 2007. Revenue for the Front End division rose to 3.363 billion euros in 2008, up 7.1% over 2007 (+7.2% LFL). Foreign exchange (currency translations) had a negative impact of 53 million euros. Revenue for the Reactors and Services division rose to 3.037 billion euros, up 11.8% over 2007 (+10.9% LFL). Foreign exchange (currency translations) had a negative impact of 47 million euros. Revenue for the Back End division came to 1.692 billion euros, a drop of 2.7% (-2.5% LFL). Foreign exchange (currency translations) had a negative impact of 3.5 million euros. Revenue for the Transmission and Distribution division rose to 5.065 billion euros in 2008, up 17.0% (+15.8% LFL)

  17. 10 CFR 95.35 - Access to matter classified as National Security Information and Restricted Data.

    Science.gov (United States)

    2010-01-01

    ... SECURITY CLEARANCE AND SAFEGUARDING OF NATIONAL SECURITY INFORMATION AND RESTRICTED DATA Control of Information § 95.35 Access to matter classified as National Security Information and Restricted Data. (a... have access to matter revealing Secret or Confidential National Security Information or Restricted Data...

  18. Mathematical Model of (R,Q Inventory Policy under Limited Storage Space for Continuous and Periodic Review Policies with Backlog and Lost Sales

    Directory of Open Access Journals (Sweden)

    Kanokwan Singha

    2017-01-01

    Full Text Available This paper involves developing new mathematical expressions to find reorder point and order quantity for inventory management policies that explicitly consider storage space capacity. Both continuous and periodic reviews, as well as backlogged and lost demand during stockout, are considered. With storage space capacity, when on-hand inventory exceeds the capacity, the over-ordering cost of storage at an external warehouse is charged on a per-unit-period basis. The objective is to minimize the total cost, consisting of ordering, shortage, holding, and over-ordering costs. Demand and lead time are stochastic and discrete in nature. Demand during varying lead time is modeled using an empirical distribution so that the findings are not subject to assumptions of demand and lead time probability distributions. Due to the complexity of the developed mathematical expressions, the problems are solved using an iterative method. The method is tested with problem instances that use real data from industry. Optimal solutions of the problem instance are determined by performing exhaustive search. The proposed method can effectively find optimal solutions for continuous review policies and near optimal solutions for periodic review policies. Fundamental insights about the inventory policies are reported from a comparison between continuous review and periodic review solutions, as well as a comparison between backlog and lost sales cases.

  19. 75 FR 5370 - Notice of Request for Clearance of an Information Collection: Omnibus Household Survey Program

    Science.gov (United States)

    2010-02-02

    .../tolerance of transportation security risk management procedures Information on journey to work...-2010-0001] Notice of Request for Clearance of an Information Collection: Omnibus Household Survey... Household Survey Program. Background: In 2005, Congress passed, and the President signed, the Safe...

  20. Drug Use and Abuse: Background Information for Security Personnel

    Science.gov (United States)

    1994-05-01

    Neurotoxicity of methamphetamine : Mechanisms of action and issues related to aging. In Miller, M. A., & Kozel, N. J., (Eds.), op. cit. 99. Cox et al...lives. This presents a dilemma for clearance adjudicators. If clearance standards are too lax, security may not be protected . If standards are too...strict, many well-adjusted, adventuresome, and creative employees may be screened out. Drug use may weaken judgment and affect ability to protect

  1. Optimal Control of Production and Remanufacturing in a Reverse Logistics Model with Backlogging

    Directory of Open Access Journals (Sweden)

    I. Konstantaras

    2010-01-01

    Full Text Available Reverse logistics activities have received increasing attention within logistics and operations management during the last years, both from a theoretical and a practical point of view. The field of reverse logistics includes all logistics processes starting with the take-back of used products from customers up to the stage of making them reusable products or disposing them. In this paper, a single-product recovery system is studied. In such system, used products are collected from customers and are kept at the recoverable inventory warehouse in view to be recovered. The constant demand rate can be satisfied either by newly produced products or by recovered ones (serviceable inventory, which are regarded as perfectly as the new ones. Excess demand is completely backlogged. Following an exact analytical approach, the optimal set-up numbers and the optimal lot sizes for the production of new products and for the recovery of returned products are obtained. A numerical cost comparison of this model with the corresponding one without backordering is also performed.

  2. Two-warehouse inventory model for deteriorating items with price-sensitive demand and partially backlogged shortages under inflationary conditions

    Directory of Open Access Journals (Sweden)

    Chandra K. Jaggi

    2015-01-01

    Full Text Available In today’s competition inherited business world, managing inventory of goods is a major challenge in all the sectors of economy. The demand of an item plays a significant role while managing the stock of goods, as it may depend on several factors viz., inflation, selling price, advertisement, etc. Among these, selling price of an item is a decisive factor for the organization; because in this competitive world of business one is constantly on the lookout for the ways to beat the competition. It is a well-known accepted fact that keeping a reasonable price helps in attracting more customers, which in turn increases the aggregate demand. Thus in order to improve efficiency of business performance organization needs to stock a higher inventory, which needs an additional storage space. Moreover, in today’s unstable global economy there is consequent decline in the real value of money, because the general level of prices of goods and services is rising (i.e., inflation. And since inventories represent a considerable investment for every organization, it is inevitable to consider the effects of inflation and time value of money while determining the optimal inventory policy. With this motivation, this paper is aimed at developing a two-warehouse inventory model for deteriorating items where the demand rate is a decreasing function of the selling price under inflationary conditions. In addition, shortages are allowed and partially backlogged, and the backlogging rate has been considered as an exponentially decreasing function of the waiting time. The model jointly optimizes the initial inventory and the price for the product, so as to maximize the total average profit. Finally, the model is analysed and validated with the help of numerical examples, and a comprehensive sensitivity analysis has been performed which provides some important managerial implications.

  3. Development of the clearance level verification evaluation system. 2. Construction of the clearance data management system

    International Nuclear Information System (INIS)

    Kubota, Shintaro; Usui, Hideo; Kawagoshi, Hiroshi

    2014-06-01

    Clearance is defined as the removal of radioactive materials or radioactive objects within authorized practices from any further regulatory control by the regulatory body. In Japan, clearance level and a procedure for its verification has been introduced under the Laws and Regulations, and solid clearance wastes inspected by the national authority can be handled and recycled as normal wastes. The most prevalent type of wastes have generated from the dismantling of nuclear facilities, so the Japan Atomic Energy Agency (JAEA) has been developing the Clearance Level Verification Evaluation System (CLEVES) as a convenient tool. The Clearance Data Management System (CDMS), which is a part of CLEVES, has been developed to support measurement, evaluation, making and recording documents with clearance level verification. In addition, validation of the evaluation result of the CDMS was carried out by inputting the data of actual clearance activities in the JAEA. Clearance level verification is easily applied by using the CDMS for the clearance activities. (author)

  4. Areva At September 30, 2010: Revenue growth to euro 6.168 bn: + 6.3%. Backlog growth to euro 42.7 bn: + 2.2%

    International Nuclear Information System (INIS)

    2010-01-01

    AREVA generated consolidated revenue of 6.168 billion euros over the first nine months of 2010 for growth of 6.3% (+5.2% like-for-like) compared with the same period in 2009. The main revenue growth engines were the Reactors and Services Business Group and the Back End Business Group, with growth of 11.5% and 7.1% respectively. Foreign exchange had a positive impact of 82 million euros over the period, while changes in consolidation scope had negligible impact. Third quarter 2010 revenue amounted to 2.011 billion euros for growth of 6.1% (+4.4% LFL) compared with the third quarter of 2009. The Reactors and Services Business Group and the Back End Business Group, posting increases of 11.2% and 9.0% respectively, continued to lead this growth. Foreign exchange had a positive impact of 39 million euros, while changes in consolidation scope had negligible impact. The group's backlog came to 42.7 billion euros at September 30, 2010, an increase of 2.2% compared with September 30, 2009 (41.8 billion euros). For the full year of 2010, the group confirms its outlook for significant revenue and backlog growth, increased operating performance excluding particular items, negative operating income, and strong growth in net income attributable to owners of the group with the contribution of the gain on the sale of the Transmission and Distribution business

  5. Areva at March 31, 2012: 2.4% revenue growth to 2026 million euros (+1.3% on a comparable basis); Backlog growth of 12 months to 45.1 billion euros (+3.7%), down slightly over 3 months (-1.0%)

    International Nuclear Information System (INIS)

    Marie, Patricia; Briand, Pauline; Michaut, Maxime; Rosso, Jerome; Scorbiac, Marie de; Repaire, Philippine du

    2012-01-01

    AREVA generated consolidated revenue of 2.026 billion euros in the first quarter of 2012, up 2.4% (+1.3% like for like) compared with the same period in 2011. The increase in revenue in the Mining Business Group (+11.9% reported, +6.5% like for like), the Reactors and Services Business Group (+5.8% reported, +6.0% like for like) and the Renewable Energies Business Group (+198.2% reported, +199.8% like for like) offsets the expected decrease in revenue in the Front End Business Group (-17.2% reported, -18.3% like for like). Foreign exchange had a positive impact of 29 million euros over the period, while changes in consolidation scope had a negative impact of 8 million euros. The Group had 45.1 billion euros in backlog at March 31, 2012, up 3.7% in relation to March 31, 2011 and down slightly (-1.0%) from December 31, 2011. Backlog growth in the Front End, Reactors and Services and Back End Business Groups offsets the decrease in backlog in the Mining and Renewable Energies Business Groups. Order cancellations as a result of the Fukushima accident totaled 612 million euros at March 31, 2012, compared with 464 million euros at December 31, 2011

  6. Recent activities on clearance in IAEA and clearance automatic laser inspection system (CLALIS)

    International Nuclear Information System (INIS)

    Hattori, Takatoshi; Sasaki, Michiya

    2005-01-01

    Exemption levels for bulk amounts of materials have been described in RS-G-1.7 published as a safety guide in IAEA on August 2004. In Japan, the Nuclear Safety Commission adopted the RS-G-1.7 values as Japanese clearance levels after the careful review of dose assessment results. After completing revises of regulatory laws in relation to clearance level, solid wastes from decommissioning and operating nuclear power plants will be targets of clearance inspection. In CRIEPI, Clearance Automatic Laser Inspection System (CLALIS) has been developed, which can give high reliability and objectivity to the measurement data. The CLALIS is a new monitoring system coupling with 3D laser shape measurement, Monte-Carlo calculation and gamma measurement techniques, which can keep a high accuracy in the measurement data using an automatic correction technique for self-shielding effects of metal waste itself and is expected to apply as a practical use in actual clearance inspections. (author)

  7. 75 FR 17305 - National Industrial Security Program Directive No. 1

    Science.gov (United States)

    2010-04-06

    ... Top Secret; Communications Security, except classified keys used for data transfer; Restricted Data... clearance under an SSA to Top Secret unless an approved NID covering the prospective Top Secret access has...

  8. Generic clearance values

    International Nuclear Information System (INIS)

    Bossio, M.C.; Muniz, C.C.

    2009-01-01

    This paper analyzes the Generic Clearance Values established for natural and artificial radionuclides with the objective of evaluating their degree of conservatism in views of adopting them into the regulatory body. Generic clearance values for natural radionuclides have been chosen by experts judgments as the optimum boundary between, on one hand, the ubiquitous unmodified soil concentrations and, on the other hand, activity concentrations in ores, mineral sands, industrial residues and wastes. For artificial radionuclides the clearance levels have been derived from the scenarios postulated in the document 'Safety Reports Series Nr 44' of the IAEA considering quantitative exemption criteria. A set of 8 scenarios were postulated covering external, ingestion and inhalation exposure pathways. For each radionuclide, the generic clearance level was derived as the more restrictive value obtained from the scenarios, that is the lowest ratio between the applicable individual dose and the dose per unit activity concentration (Bq/g). The individual dose was calculated by a formula depending on each scenario and pathway, with different parameters, such as exposure time, dosimetric factors, dilution factor, density of the material, geometric factors, etc. It was concluded that the basis and parameters used for the derivation of the generic clearance levels are quite conservative and therefore its the adoption in Argentina has been recommended. It is expected that their implementation will contribute to optimize the regulatory management system. (author)

  9. Generic Clearance Values

    International Nuclear Information System (INIS)

    Bossio, M.C.; Muniz, C.C.

    2010-01-01

    This paper analyzes the Generic Clearance Values established for natural and artificial radionuclides with the objective of evaluating their degree of conservatism in views of adopting them into the regulatory body. Generic clearance values for natural radionuclides have been chosen by experts judgments as the optimum boundary between, on the one hand, the ubiquitous unmodified soil concentrations and, on the other hand, activity concentrations in ores, mineral sands, industrial residues and wastes. For artificial radionuclides the clearance levels have been derived from the scenarios postulated in the document Safety Reports Series 44 of the IAEA considering quantitative exemption criteria. A set of 8 scenarios were postulated covering external, ingestion and inhalation exposure pathways. For each radionuclide, the generic clearance level was derived as the more restrictive value obtained from the scenarios, that is the lowest ratio between the applicable individual dose and the dose per unit activity concentration (Bq/g). The individual dose was calculated by a formula depending on each scenario and pathway, with different parameters, such as exposure time, dosimetric factors, dilution factor, density of the material, geometric factors, etc. It was concluded that the basis and parameters used for the derivation of the generic clearance levels are quite conservative and therefore its the adoption in Argentina has been recommended. It is expected that their implementation will contribute to optimize the regulatory management system. (authors) [es

  10. Airway Clearance Techniques (ACTs)

    Medline Plus

    Full Text Available ... Treatments and Therapies Airway Clearance Airway Clearance Techniques (ACTs) There are different ways to clear your airways. ... or caregiver. Older kids and adults can choose ACTs that they can do on their own. Share ...

  11. Airway Clearance Techniques (ACTs)

    Medline Plus

    Full Text Available ... D Structure Consortium CFTR Folding Consortium Epithelial Stem Cell Consortium Mucociliary Clearance Consortium SUCCESS WITH THERAPIES RESEARCH ... clapping) or vibration to loosen mucus from airway walls. See how different airway clearance techniques work to ...

  12. Airway Clearance Techniques (ACTs)

    Medline Plus

    Full Text Available ... Active Cycle of Breathing Technique Airway Clearance Techniques Autogenic Drainage Basics of Lung Care Chest Physical Therapy ... clearance. Facebook Twitter Email More Related Content Medications Autogenic Drainage Positive Expiratory Pressure High-Frequency Chest Wall ...

  13. Airway Clearance Techniques (ACTs)

    Medline Plus

    Full Text Available ... today. ANNUAL FUND Become a Corporate Supporter Cause Marketing Make a Charitable Gift Our Corporate Supporters Workplace ... Clearance Airway Clearance Techniques (ACTs) There are different ways to clear your airways. Most are easy to ...

  14. Airway Clearance Techniques (ACTs)

    Medline Plus

    Full Text Available ... a range of treatment options. Airway Clearance Active Cycle of Breathing Technique Airway Clearance Techniques Autogenic Drainage ... LEGACY GIFT Sponsor a Participant CF Climb CF Cycle for Life Great Strides Xtreme Hike Participate In ...

  15. Study on clearance system

    International Nuclear Information System (INIS)

    Onishi, Yuko; Miura, Hiroshi; Kawasaki, Satoru

    2011-01-01

    The clearance system is a legal system to release 'the radioactive waste not requiring treatment as radioactive waste' from the regulatory control. JNES supports NISA on approval and confirmation of clearance measurement and judgment developed by the operator. The objective of this study is to establish technical base of the validation method of the clearance measurement for various objects. In reactor facilities, the bulk measurement technique or the statistical sampling measurement technique may be applied to large scale objects or concrete walls. In this study, the criteria of those techniques were examined. In uranium processing facilities, it is important to confirm surface state of the object in case of detecting alpha rays. The result of the examination about the influence of the surface rust in the uranium clearance measurement by the alpha ray measurement showed that the pollution was distributed in rust layer uniformly. This result will be reflected to the revision of the Ministerial Ordinance on Clearance in 2011FY. To develop a manual for unexpected incidents, the response procedure for an unexpected incident was prepared, including a response system. (author)

  16. Airway Clearance Techniques (ACTs)

    Medline Plus

    Full Text Available ... to loosen mucus from airway walls. See how different airway clearance techniques work to help you clear the thick, sticky mucus ... Offer their tips for fitting ACTs into daily life Airway Clearance Techniques | Webcast ... Facebook Twitter ...

  17. Training people from disadvantaged groups in computer use: Is the backlog not too big to overcome?

    Directory of Open Access Journals (Sweden)

    Pieter Blignaut

    2007-09-01

    Full Text Available The digital divide is both a matter of having access to technology and being able to use it. There are several initiatives to roll out Information and Communication Technology (ICT in public places in South Africa, but the question arises as to whether people will be able to use it effectively. Is the backlog with regard to general education and training not so insurmountable that people from disadvantaged communities are not educable for computer usage? This paper reports on the experiences and observations of instructors during a word processing training course for people from such communities. An interaction model that incorporates user and interface limitations with the difficulties experienced, serves as framework for the discussion. It became clear that most of the difficulties that attendees experienced were related to lack of technological experience, a limitation that can be eliminated through practice and perseverance. Enough practice might also result in an attenuation of the effects of some psychological limitations.

  18. Evaluation of serum iohexol clearance for use in predicting carboplatin clearance in cats.

    Science.gov (United States)

    Bailey, Dennis B; Rassnick, Kenneth M; Prey, Joshua D; Dykes, Nathan L

    2009-09-01

    To determine whether a glomerular filtration rate (GFR) assay based on serum iohexol clearance can be used to predict carboplatin clearance in cats. 10 cats with tumors. GFR was measured concurrently by use of plasma clearance of technetium Tc 99m-labeled diethylenetriaminepentaacetic acid ((99m)Tc-DTPA) to yield GFR(99mTc-DTPA) and serum clearance of iohexol to yield GFR(Iohexol). A single dose of carboplatin was administered IV as a bolus. Dose was calculated by use of a target value for the area under the plasma platinum concentration-versus-time curve (AUC(Target)) and estimation of platinum clearance (CL(PT)) derived from GFR(99mTc-DTPA) as follows: dose = AUC(Target) x 2.6 x GFR(99mTc-DTPA) x body weight, where AUC(Target) is 2.75 min.mg.mL(-1). Plasma platinum concentrations were measured via atomic absorption spectrophotometry. Values for GFR(99mTc-DTPA) and GFR(Iohexol) were compared by use of least-squares regression and Bland-Altman analysis. Least-squares regression was used to determine whether CL(PT) could be predicted from GFR(99mTc-DTPA) or GFR(Iohexol) (or both). GFR(99mTc-DTPA) and GFR(Iohexol) were strongly correlated (r = 0.90), but GFR(Iohexol) values were significantly larger by a factor of approximately 1.4. Platinum clearance had a significant linear relationship to GFR(99mTc-DTPA) (CL(PT) = 2.5 x GFR(99mTc-DTPA)) and to GFR(Iohexol) (CL(PT) = [1.3 x GFR(Iohexol)] + 1.4). In cats, serum iohexol clearance was an accurate predictor of CL(PT) and can be used to calculate the carboplatin dose as follows: dose = AUC(Target) x ([1.3 x GFR(Iohexol)] + 1.4) x body weight.

  19. Airway Clearance Techniques (ACTs)

    Medline Plus

    Full Text Available ... and Their Families When There's More Than One Person With CF in the Same School Daily Life ... Awards and Grants Career Development Awards Research Awards Training Awards CF ... Clearance Airway Clearance Techniques (ACTs) There are different ways to clear your ...

  20. Airway Clearance Techniques (ACTs)

    Medline Plus

    Full Text Available ... Team Your cystic fibrosis care team includes a group of CF health care professionals who partner with ... Awards and Grants Career Development Awards Research Awards Training Awards CF ... Clearance Airway Clearance Techniques (ACTs) There are different ways to clear your ...

  1. Clearance Kinetics and Clearance Routes of Molecules From the Suprachoroidal Space After Microneedle Injection.

    Science.gov (United States)

    Chiang, Bryce; Wang, Ke; Ethier, C Ross; Prausnitz, Mark R

    2017-01-01

    To determine clearance kinetics and routes of clearance of molecules from the suprachoroidal space (SCS) of live New Zealand White rabbits. Suprachoroidal space collapse rate and pressure changes after microneedle injection into SCS were determined. Fluorescent fundus images were acquired to determine clearance rates of molecules ranging in size from 332 Da to 2 MDa. Microneedle injections of fluorescein were performed, and samples were taken from various sites over time to determine amount of fluorescein exiting the eye. Clearance transport was modeled theoretically and compared with experimental data. After injection, pressures in SCS and vitreous humor spiked and returned to baseline within 20 minutes; there was no difference between these two pressures. Suprachoroidal space collapse occurred within 40 minutes. One hour after fluorescein injection, 46% of fluorescein was still present in the eye, 15% had transported across sclera, 6% had been cleared by choroidal vasculature, and 4% had exited via leakage pathways. Characteristic clearance time increased in proportion with molecular radius, but total clearance of 2 MDa FITC-dextran was significantly slower (21 days) than smaller molecules. These data generally agreed with predictions from a theoretical model of molecular transport. Guided by experimental data in the context of model predictions, molecular clearance from SCS occurred in three regimes: (1) on a time scale of approximately 10 minutes, fluid and molecules exited SCS by diffusion into sclera and choroid, and by pressure-driven reflux via transscleral leakage sites; (2) in approximately 1 hour, molecules cleared from choroid by blood flow; and (3) in 1 to 10 hours, molecules cleared from sclera by diffusion and convection.

  2. Study on clearance system

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2013-08-15

    The clearance system is a legal system to release 'the radioactive waste not requiring treatment as radioactive waste' from the regulatory control. JNES supports Nuclear Regulatory Agency on approval and confirmation of clearance measurement and judgment developed by the operator. The objective of this study is to establish technical base of the validation method of the clearance measurement for various objects. In uranium processing facilities, simulation sources emitting alpha-rays is used in a validity confirmation examination of the measuring equipment. In this study, these sources were examined by measuring alpha and beta spectra to evaluate the applicability and problem of these sources. In addition, the measuring method detecting gamma-rays was examined. This method can be applied to complicated objects. As a part to develop a manual for unexpected incidents in clearance system, a quick method for measurement of Strontium 90 was examined. In addition, the measuring methods for the judgment of the influence of fallout and for NR (Non-Radioactive) confirmation were examined. (author)

  3. Strong backlog growth of 22.3% compared to September 30, 2008. Strong third quarter revenue growth of 7.8%, bringing sales for the first nine months of 2009 to 9.7 billion, or +6.4%

    International Nuclear Information System (INIS)

    2009-01-01

    AREVA generated consolidated revenue of 9.686 billion euros over the first nine months of 2009 for growth of 6.4% (+4.0% like-for-like) compared with the same period in 2008. Revenue outside France was up 8.4% to 6.999 billion euros, representing 72% of total revenue. The main revenue growth engines were the Front End division and the Transmission and Distribution division, with growth of 7.6% and 12.4% respectively. Foreign exchange had a positive impact of 91 million euros. Changes in the consolidation scope had an impact of 117 million euros, corresponding to the consolidation of acquisitions made by AREVA TA and the Transmission and Distribution division in 2008 and 2009. Third quarter 2009 revenue rose 7.8% to 3.164 billion euros (+6.7% like-for-like) compared with the third quarter of 2008. Changes in the consolidation scope had a positive impact of 31 million euros. The foreign exchange impact was minimal for the period. Quarterly growth was fueled mostly by the Front End division (+13.7%), the Back End division (+7.1%) and the Transmission and Distribution division (+8.4%). The group's backlog stood at 47.5 billion euros as of September 30, 2009 for 22.3% growth year-on-year. The backlog is up 27.4% in Nuclear and down 5.6% in Transmission and Distribution. For 2009 as a whole, the group confirms its outlook, based on the consolidation scope as of June 30, 2009, for a strong growth in backlog and in revenue and operating income close to that of the financial year 2008

  4. A Partial Backlogging Inventory Model for Deteriorating Item under Fuzzy Inflation and Discounting over Random Planning Horizon: A Fuzzy Genetic Algorithm Approach

    Directory of Open Access Journals (Sweden)

    Dipak Kumar Jana

    2013-01-01

    Full Text Available An inventory model for deteriorating item is considered in a random planning horizon under inflation and time value money. The model is described in two different environments: random and fuzzy random. The proposed model allows stock-dependent consumption rate and shortages with partial backlogging. In the fuzzy stochastic model, possibility chance constraints are used for defuzzification of imprecise expected total profit. Finally, genetic algorithm (GA and fuzzy simulation-based genetic algorithm (FSGA are used to make decisions for the above inventory models. The models are illustrated with some numerical data. Sensitivity analysis on expected profit function is also presented. Scope and Purpose. The traditional inventory model considers the ideal case in which depletion of inventory is caused by a constant demand rate. However, to keep sales higher, the inventory level would need to remain high. Of course, this would also result in higher holding or procurement cost. Also, in many real situations, during a longer-shortage period some of the customers may refuse the management. For instance, for fashionable commodities and high-tech products with short product life cycle, the willingness for a customer to wait for backlogging is diminishing with the length of the waiting time. Most of the classical inventory models did not take into account the effects of inflation and time value of money. But in the past, the economic situation of most of the countries has changed to such an extent due to large-scale inflation and consequent sharp decline in the purchasing power of money. So, it has not been possible to ignore the effects of inflation and time value of money any more. The purpose of this paper is to maximize the expected profit in the random planning horizon.

  5. Clearance of materials from accelerator facilities

    Directory of Open Access Journals (Sweden)

    Rokni Sayed H.

    2017-01-01

    Full Text Available A new Technical Standard that supports the clearance of materials and equipment (personal property from U.S. Department of Energy (DOE accelerator facilities has been developed. The Standard focuses on personal property that has the potential to be radiologically impacted by accelerator operations. It addresses material clearance programs and protocols for off-site releases without restriction on use. Common metals with potential volumetric activation are of main interest with technical bases provided in Appendices of the Standard. The clearance protocols in the Standard include three elements: 1 clearance criteria, 2 process knowledge, and 3 measurement methods. This paper presents the technical aspects of the new Standard, discusses operational experience gained in clearance of materials and equipment from several accelerator facilities at SLAC and examples as to how this Standard can be applied to benefit the entirety of the DOE Accelerator Complex.

  6. An EOQ model of time quadratic and inventory dependent demand for deteriorated items with partially backlogged shortages under trade credit

    Science.gov (United States)

    Singh, Pushpinder; Mishra, Nitin Kumar; Singh, Vikramjeet; Saxena, Seema

    2017-07-01

    In this paper a single buyer, single supplier inventory model with time quadratic and stock dependent demand for a finite planning horizon has been studied. Single deteriorating item which suffers shortage, with partial backlogging and some lost sales is considered. Model is divided into two scenarios, one with non permissible delay in payment and other with permissible delay in payment. Latter is called, centralized system, where supplier offers trade credit to retailer. In the centralized system cost saving is shared amongst the two. The objective is to study the difference in minimum costs borne by retailer and supplier, under two scenarios including the above mentioned parameters. To obtain optimal solution of the problem the model is solved analytically. Numerical example and a comparative study are then discussed supported by sensitivity analysis of each parameter.

  7. Clearance and release from control - An international perspective

    International Nuclear Information System (INIS)

    Thierfeldt, S.

    2005-01-01

    This paper tries to give an overview of the clearance, or release from regulatory control, on an international scale, including some of those countries where clearance has become or is about to become vital for D and D. The emphasis lies on the impact of clearance, and in particular of differences between clearance levels of various countries, on D and D. Relevance of clearance for D and D of nuclear installations Clearance is an essential part of waste management (or more general, material management) in nuclear installations, and in particular during the decommissioning phase where waste streams continues to arise. Of course, the relevance of clearance in a particular country depends on a number of factors, like: availability of a final repository and its price; prevailing decommissioning strategy; number of nuclear installations reaching decommissioning phase. This small selection of reasons why clearance may be of varying importance for different countries may already suffice to illustrate why up to now clearance has been developed and implemented in quite different ways. If one thinks of additional reasons that may influence clearance, like politics, the public opinion, availability of funds etc., the situation becomes even more complex. It is, however safe to draw the conclusion that countries with a certain number of nuclear installations which have been or will soon be shut down or which are already in the decommissioning phase will need to implement provisions for clearance. This has indeed been the case with countries like the UK, Germany, the USA, Sweden, and a number of others. It is not essential for clearance levels to be exactly equal between various countries. They may differ as long as the difference is not too large, e.g. the values fall into the same order of magnitude. This is the reason why for example Germany has no problems with clearance levels which differ from the EU recommendation RP 122 partially adopted in a number of EU countries

  8. Rational customs clearance technology choice

    OpenAIRE

    Shramenko, N.; Andriets, V.

    2008-01-01

    Issues concerning cargo delivery efficiencyincrease by choice of rational customs clearance technology have been considered. Three possible variants of customs clearance andmethods which allow to define the most rational version of cargo delivery in international road communication based on main efficiency criteria for definite distance have been presented.

  9. 7 CFR 1927.55 - Title clearance services.

    Science.gov (United States)

    2010-01-01

    ... REGULATIONS TITLE CLEARANCE AND LOAN CLOSING Real Estate Title Clearance and Loan Closing § 1927.55 Title clearance services. (a) Responsibilities of closing agents. Services to be provided to the agency and the borrower by a closing agent in connection with the transaction vary depending on whether a title insurance...

  10. Relationship between silicon concentration and creatinine clearance

    International Nuclear Information System (INIS)

    Miura, Y.; Nakai, K.; Itoh, C.; Horikiri, J.; Sera, K.; Sato, M.

    1998-01-01

    Silicon levels in dialysis patients are markedly increasing. Using PIXE we determined the relationship between silicon concentration and creatinine clearance in 30 samples. Urine silicon concentration were significantly correlated to creatinine clearance (p<0.001). And also serum silicon concentration were significantly correlated to creatinine clearance (p<0.0001). (author)

  11. Backlog at December 31, 2007: euro 39,8 billion, up by 55% from year-end 2006. 2007 sales revenue: euro 11.9 billion, up by 9.8% (+10.4% like-for-like)

    International Nuclear Information System (INIS)

    2008-01-01

    The AREVA group's backlog reached a record level of euro 39.834 billion as of December 31, 2007, up by 55% from that of year-end 2006. In Nuclear, the backlog was euro 34.927 billion at year-end 2007 (+58%), due in particular to the signature of a contract in a record amount with the Chinese utility CGNPC. The series of agreements concluded provide among other things for the construction of two new-generation EPR nuclear islands and the supply of all of the materials and services needed for their operation through 2027. CGNPC also bought 35% of the production of UraMin, the mining company acquired by AREVA in August 2007. Industrial cooperation in the Back End of the cycle was launched with the signature of an agreement between China and France. In addition, the group signed several long-term contracts in significant amounts, particularly with KHNP of South Korea, EDF and Japanese utilities. The Transmission and Distribution division won several major contracts in Libya and Qatar at the end of the year approaching a total of euro 750 million. For the entire year, new orders grew by 34% to euro 5.816 billion. The backlog, meanwhile, grew by 40% to euro 4.906 billion at year-end. The group cleared sales revenue of euro 11.923 billion in 2007, up by 9.8% (+10.4% like-for-like) in relation to 2006 sales of euro 10.863 billion. Sales revenue for the 4. quarter of 2007 rose to euro 3.858 billion, for growth of 16.7% (+18.8% like-for-like) over one year. Sales revenue for the year was marked by: - Growth of 7.6% (+10.6% like-for-like) in Front End sales revenue, which rose to euro 3.140 billion. The division's Enrichment operations posted strong growth. - Sales were up by 17.5% (+15.2% like-for-like) to euro 2.717 billion in the Reactors and Services division. Sales revenue was driven in particular by the growth of Services operations, after weak demand in 2006, by progress on OL3 construction, and by the start of Flamanville 3, the second EPR. For the Back End division

  12. Compressor airfoil tip clearance optimization system

    Science.gov (United States)

    Little, David A.; Pu, Zhengxiang

    2015-08-18

    A compressor airfoil tip clearance optimization system for reducing a gap between a tip of a compressor airfoil and a radially adjacent component of a turbine engine is disclosed. The turbine engine may include ID and OD flowpath boundaries configured to minimize compressor airfoil tip clearances during turbine engine operation in cooperation with one or more clearance reduction systems that are configured to move the rotor assembly axially to reduce tip clearance. The configurations of the ID and OD flowpath boundaries enhance the effectiveness of the axial movement of the rotor assembly, which includes movement of the ID flowpath boundary. During operation of the turbine engine, the rotor assembly may be moved axially to increase the efficiency of the turbine engine.

  13. Noninvasive determination of individual renal clearance

    International Nuclear Information System (INIS)

    Chanard, J.; Brunois, J.P.; Ruiz, J.C.; Assailly, J.

    1980-01-01

    A noninvasive method for measurement of individual renal clearance is presented, based on analysis of the early rise of the kidneys' time-activity curves after injection of an appropriate tracer ( 131 I-ortho-iodohippurate for tubular function or 111 In DTPA for glomerular clearance). The analysis is based on the assumption that an insignificant amount of tracer leaves the kidney during the first few moments following injection. Therefore, the kidney activity during this period is directly proportional to the integral of the blood (heart) activity. After blood background subtraction, the linear correlation between the early part of the renogram and the corresponding blood integral activity curve allows calculation of an angular coefficient. The ratio of these coefficients calculated for each kidney is proportional to the ratio of the individual clearances. The latter are calculated from the total clearance simultaneously measured using a simplified method without urine collection. In control subjects with normal renal function individual renal clearances were not significantly different. In uninephrectomized patients a precision of 5% in calculating individual clearance was estimated from data recorded at the level of the remaining kidney. In patients with functional asymmetry, results were compared with 197 HgCl 2 quantitative renal fixation. A linear correlation was found (r = 0.95). The method we propose seems valuable for clinical investigation and allows sequential measurements. (orig.)

  14. A model of clearance rate regulation in mussels

    Science.gov (United States)

    Fréchette, Marcel

    2012-10-01

    Clearance rate regulation has been modelled as an instantaneous response to food availability, independent of the internal state of the animals. This view is incompatible with latent effects during ontogeny and phenotypic flexibility in clearance rate. Internal-state regulation of clearance rate is required to account for these patterns. Here I develop a model of internal-state based regulation of clearance rate. External factors such as suspended sediments are included in the model. To assess the relative merits of instantaneous regulation and internal-state regulation, I modelled blue mussel clearance rate and growth using a DEB model. In the usual standard feeding module, feeding is governed by a Holling's Type II response to food concentration. In the internal-state feeding module, gill ciliary activity and thus clearance rate are driven by internal reserve level. Factors such as suspended sediments were not included in the simulations. The two feeding modules were compared on the basis of their ability to capture the impact of latent effects, of environmental heterogeneity in food abundance and of physiological flexibility on clearance rate and individual growth. The Holling feeding module was unable to capture the effect of any of these sources of variability. In contrast, the internal-state feeding module did so without any modification or ad hoc calibration. Latent effects, however, appeared transient. With simple annual variability in temperature and food concentration, the relationship between clearance rate and food availability predicted by the internal-state feeding module was quite similar to that observed in Norwegian fjords. I conclude that in contrast with the usual Holling feeding module, internal-state regulation of clearance rate is consistent with well-documented growth and clearance rate patterns.

  15. Predicting Human Clearance of OATP substrates using Cynomolgus monkey: In vitro-in vivo scaling of hepatic uptake clearance.

    Science.gov (United States)

    de Bruyn, Tom; Ufuk, Ayse; Cantrill, Carina; Kosa, Rachel E; Bi, Yi-An; Niosi, Mark; Modi, Sweta; Rodrigues, A David; Tremaine, Larry M; Varma, Manthena Vs; Galetin, Aleksandra; Houston, J Brian

    2018-05-02

    This work explores the utility of the cynomolgus monkey as a preclinical model to predict hepatic uptake clearance mediated by organic anion transporting polypeptide (OATP) transporters. Nine OATP substrates (rosuvastatin, pravastatin, repaglinide, fexofenadine, cerivastatin, telmisartan, pitavastatin, bosentan and valsartan) were investigated in plated cynomolgus monkey and human hepatocytes. Total uptake clearance and passive diffusion were measured in vitro from initial rates in the absence and presence of the OATP inhibitor rifamycin SV, respectively. Total uptake clearance values in plated hepatocytes ranged over three orders of magnitude in both species with a similar rank order and good agreement in the relative contribution of active transport to total uptake between cynomolgus monkey and human. In vivo hepatic clearance for these nine drugs was determined in cynomolgus monkey after intravenous dosing. Hepatic clearances showed a similar range to human parameters and good predictions from respective hepatocyte parameters (with 2.7 and 3.8-fold bias on average, respectively). The use of cross species empirical scaling factors (based on either dataset average or individual drug scaling factor from cynomolgus monkey data) improved prediction (less bias, better concordance) of human hepatic clearance from human hepatocyte data alone. In vitro intracellular binding in hepatocytes also correlated well between species. It is concluded that the minimal species differences observed for the current dataset between cynomolgus monkey and human hepatocyte uptake, both in vitro and in vivo, support future use of this preclinical model to delineate drug hepatic uptake and enable prediction of human in vivo intrinsic hepatic clearance. The American Society for Pharmacology and Experimental Therapeutics.

  16. Areva at December 31, 2014: Revenue down at Euros 8.336 bn: -8.0% (-7.2% like for like), Backlog at Euros 46.9 bn

    International Nuclear Information System (INIS)

    Repaire, Philippine du

    2015-01-01

    At 46.9 billion euros at December 31, 2014, the group's backlog grew in certain recurring businesses, thanks to long-term contracts with EDF. Nevertheless, the group suffers from the lackluster of markets with short-term sales cycles, as is the case for services to the installed base, and from the postponement of certain customer projects. The group's revenue for 2014, which was down 7.2% like for like, slightly exceeded the group's expectations. The decrease is due to the deterioration of market conditions throughout 2014 and to an unfavorable basis of comparison, with non-recurring contracts in the Mining and Back End businesses having benefited the year of 2013

  17. 48 CFR 801.602-76 - Business clearance review.

    Science.gov (United States)

    2010-10-01

    ... 48 Federal Acquisition Regulations System 5 2010-10-01 2010-10-01 false Business clearance review... GENERAL DEPARTMENT OF VETERANS AFFAIRS ACQUISITION REGULATION SYSTEM Career Development, Contracting Authority, and Responsibilities 801.602-76 Business clearance review. (a) A business clearance review is a...

  18. Estimation of 131I hippuran clearance during pregnancy

    International Nuclear Information System (INIS)

    Voigt, R.; Stoll, W.; Zenner, I.; Arndt, J.; Friedrich-Schiller-Univ., Jena

    1979-01-01

    Changes in 131 I hippuran clearance were estimated by a non-catheter method, as well as total clearance and clearance of each kidney, in 43 women at various stages of pregnancy and in 13 non-pregnant women who were not using hormonal contraceptives. The results are demonstrated in graph form. The methods used are described in detail. The procedure for determining clearance in separate kidneys is indicated. It was found that clearance values increased up to the 35th and 26th weeks of pregnancy. The difference between the sides that were found corresponds with the previously known difference in the function of the right and left kidneys and ureters. (orig.) [de

  19. Establishing exemption and clearance criteria by the regulatory authority

    International Nuclear Information System (INIS)

    Salih, A.E.A.

    2012-04-01

    This Project work discusses the relationship between the concepts of exemption and clearance, and their practical use in the overall scheme of regulatory control of practices. It also discusses how exemptions and clearance is established and the scope of its applications for regulatory control. The concept of general clearance levels for any type of material and any possible pathway of disposal is also introduced in this work. Guidance of the Group of Experts establishing scenarios for general clearance, parameter values, and a nuclide-specific list of calculated clearance levels is also presented. Regulatory authorities are required to develop guidance on exemption and clearance levels to assist licensees and registrants to know which practices and sources within practices are exempted from regulatory control and those to be cleared from further controls. Exemption and clearance levels are tools for assisting the Regulatory Authority to optimize the use of resources. (author)

  20. 14 CFR 1260.63 - Customs clearance and visas.

    Science.gov (United States)

    2010-01-01

    ... 14 Aeronautics and Space 5 2010-01-01 2010-01-01 false Customs clearance and visas. 1260.63 Section 1260.63 Aeronautics and Space NATIONAL AERONAUTICS AND SPACE ADMINISTRATION GRANTS AND COOPERATIVE AGREEMENTS General Special Conditions § 1260.63 Customs clearance and visas. Customs Clearance and Visas (For...

  1. The influence of body posture on lithium clearance

    DEFF Research Database (Denmark)

    Kamper, A L; Strandgaard, S; Holstein-Rathlou, N H

    1988-01-01

    To establish appropriate standard circumstances for lithium clearance measurements, a study was undertaken in 12 healthy volunteers. In each subject, the glomerular filtration rate (GFR), as estimated by [51Cr]EDTA plasma clearance, and the renal clearances of lithium, sodium and potassium were...... during moderate physical activity. Hence, when renal tubular function is studied with the lithium clearance method, standardization of posture and physical activity is important. In such studies physical activity such as walking should particularly be avoided....... measured four times at 1-week intervals: two in the supine and one in the sitting position, and one when the subject was walking around. Glomerular filtration rate was not influenced by posture changes. On the contrary, lithium clearance, which in the supine position was 30 +/- 9 ml/min (1 SD), tended...

  2. The influence of body posture on lithium clearance

    DEFF Research Database (Denmark)

    Kamper, A L; Strandgaard, S; Holstein-Rathlou, N H

    1988-01-01

    To establish appropriate standard circumstances for lithium clearance measurements, a study was undertaken in 12 healthy volunteers. In each subject, the glomerular filtration rate (GFR), as estimated by [51Cr]EDTA plasma clearance, and the renal clearances of lithium, sodium and potassium were...... measured four times at 1-week intervals: two in the supine and one in the sitting position, and one when the subject was walking around. Glomerular filtration rate was not influenced by posture changes. On the contrary, lithium clearance, which in the supine position was 30 +/- 9 ml/min (1 SD), tended...... during moderate physical activity. Hence, when renal tubular function is studied with the lithium clearance method, standardization of posture and physical activity is important. In such studies physical activity such as walking should particularly be avoided....

  3. Clearance Laboratory - Capability and measurement sensitivity

    Energy Technology Data Exchange (ETDEWEB)

    Hedemann Jensen, P.; Lauridsen, B.; Silva, J.; Soegaard-Hansen, J.; Warming, L.

    2005-08-01

    A new low-level Clearance Laboratory has been built at the Risoe-site. Building materials with a low content of naturally occurring radionuclides have been used. To minimize transport of radon gas from soil into the laboratory the foundation has been supplied with a membrane. The laboratory has been equipped with two high-efficiency germanium detectors. These detectors will be used for clearance measurements on the predicted amount of 15,000 - 18,000 tonnes of non-active or nearly non-active materials, which will originate from the decommissioning of all the nuclear facilities at the Risoe-site. They will be used also for clearance measurements on buildings and land. Objects and materials to be measured for clearance are placed on a rotation table that can carry up to one tonne and can rotate once a minute to simulate some averaging of inhomogeneously distributed activity. Sensitivity and background measurements reveal that measuring times of 20 - 50 minutes would normally be sufficient to detect radionuclide concentrations of only a small fraction of the nuclide-specific clearance levels with a sufficiently low uncertainty. Probability calculations of the measurement capacity of the Clearance Laboratory indicate that the mean value of the total measuring time for all materials that potentially can be cleared would be 13 years with a 95% probability of being less than 25 years. The mean value of the annual amount of materials that can be measured in the laboratory is 600 tonnes with a 95% probability of being less than 1,200 tonnes. If needed, there is room for additional measuring systems to increase the capacity of the laboratory. (au)

  4. Clearance Laboratory - Capability and measurement sensitivity

    International Nuclear Information System (INIS)

    Hedemann Jensen, P.; Lauridsen, B.; Silva, J.; Soegaard-Hansen, J.; Warming, L.

    2005-09-01

    A new low-level Clearance Laboratory has been built at the Risoe-site. Building materials with a low content of naturally occurring radionuclides have been used. To minimize transport of radon gas from soil into the laboratory the foundation has been supplied with a membrane. The laboratory has been equipped with two high-efficiency germanium detectors. These detectors will be used for clearance measurements on the predicted amount of 15,000 - 18,000 tonnes of non-active or nearly non-active materials, which will originate from the decommissioning of all the nuclear facilities at the Risoe-site. They will be used also for clearance measurements on buildings and land. Objects and materials to be measured for clearance are placed on a rotation table that can carry up to one tonne and can rotate once a minute to simulate some averaging of inhomogeneously distributed activity. Sensitivity and background measurements reveal that measuring times of 20 - 50 minutes would normally be sufficient to detect radionuclide concentrations of only a small fraction of the nuclide-specific clearance levels with a sufficiently low uncertainty. Probability calculations of the measurement capacity of the Clearance Laboratory indicate that the mean value of the total measuring time for all materials that potentially can be cleared would be 13 years with a 95% probability of being less than 25 years. The mean value of the annual amount of materials that can be measured in the laboratory is 600 tonnes with a 95% probability of being less than 1,200 tonnes. If needed, there is room for additional measuring systems to increase the capacity of the laboratory. (au)

  5. Two-warehouse partial backlogging inventory model for deteriorating items with linear trend in demand under inflationary conditions

    Science.gov (United States)

    Jaggi, Chandra K.; Khanna, Aditi; Verma, Priyanka

    2011-07-01

    In today's business transactions, there are various reasons, namely, bulk purchase discounts, re-ordering costs, seasonality of products, inflation induced demand, etc., which force the buyer to order more than the warehouse capacity. Such situations call for additional storage space to store the excess units purchased. This additional storage space is typically a rented warehouse. Inflation plays a very interesting and significant role here: It increases the cost of goods. To safeguard from the rising prices, during the inflation regime, the organisation prefers to keep a higher inventory, thereby increasing the aggregate demand. This additional inventory needs additional storage space, which is facilitated by a rented warehouse. Ignoring the effects of the time value of money and inflation might yield misleading results. In this study, a two-warehouse inventory model with linear trend in demand under inflationary conditions having different rates of deterioration has been developed. Shortages at the owned warehouse are also allowed subject to partial backlogging. The solution methodology provided in the model helps to decide on the feasibility of renting a warehouse. Finally, findings have been illustrated with the help of numerical examples. Comprehensive sensitivity analysis has also been provided.

  6. Lithium clearance in chronic nephropathy

    DEFF Research Database (Denmark)

    Kamper, A L; Holstein-Rathlou, N H; Leyssac, P P

    1989-01-01

    1. Lithium clearance measurements were made in 72 patients with chronic nephropathy of different aetiology and moderate to severely reduced renal function. 2. Lithium clearance was strictly correlated with glomerular filtration rate, and there was no suggestion of distal tubular reabsorption...... of lithium or influence of osmotic diuresis. 3. Fractional reabsorption of lithium was reduced in most patients with glomerular filtration rates below 25 ml/min. 4. Calculated fractional distal reabsorption of sodium was reduced in most patients with glomerular filtration rates below 50 ml/min. 5. Lithium...... that lithium clearance may be a measure of the delivery of sodium and water from the renal proximal tubule. With this assumption it was found that adjustment of the sodium excretion in chronic nephropathy initially takes place in the distal parts of the nephron (loop of Henle, distal tubule and collecting duct...

  7. Experience and lessons learnt from clearance in Germany

    International Nuclear Information System (INIS)

    Thierfeldt, Stefan

    2002-01-01

    Clearance is an important corner-stone of waste management in nuclear installations in Germany. It has been practised successfully for around two decades. The importance of clearance can also be judged from the fact that it has been included detailedly in the new German Radiation Protection Ordinance. Currently, there are 19 NPPs and a number of fuel cycle installations in operation in Germany. The main waste quantities, however, arise from the dismantling of NPPs and fuel cycle installations which are currently in decommissioning. As most of the decommissioning projects are targeted for early dismantling instead of safe enclosure, there is already considerable experience with the application of clearance procedures and verification of clearance levels. The German waste management strategy is governed by two options: Clearance of the material (after decontamination and release measurement). After clearance, the material is no longer regarded as radioactive in a legal sense. Final disposal of the material as radioactive waste in a deep geological repository (no near-surface disposal facilities exist or are planned in Germany). A deep geological repository is planned to be operable around 2030. Stefan Thierfeldt described German clearance requirements and lessons learned from their application to decommissioning of power reactors. The great majority of the waste was in fact recycled, although the costs were dominated by the small fraction that had to be disposed of as radioactive waste. Among the lessons learned from the German experience were some revealing insights into the public perception of both clearance and of recycling of material from decommissioning of a nuclear installation

  8. 19 CFR 122.26 - Entry and clearance.

    Science.gov (United States)

    2010-04-01

    ... AIR COMMERCE REGULATIONS Private Aircraft § 122.26 Entry and clearance. Private aircraft, as defined... information as set forth in § 122.22(c), and grants electronic clearance via electronic mail or telephone...

  9. Comparison of renal clearance of 99mTc-DTPA and inulin, 131I-hippurate and PAH as well as of the creatinine clearance in Wistar rats

    International Nuclear Information System (INIS)

    Hagemann, J.; Li Min Su; Strangfeld, D.; Schuerer, M.; Siewert, H.; Pietsch, R.; Kruse, I.; Priem, F.

    1988-01-01

    Order of magnitude and standard deviation of 99m Tc-DTPA and 131 I-hippurate slope clearance were analyzed successively in 56 male Wistar rats. The clearance of 99m Tc-DTPA was 17.4 ± 3.43 μl · s -1 (100 g b-w) -1 , of 131 I-hippurate 34.3 ± 7.21 μl · s -1 (100 g b-w) -1 . In 17 rats inulin and PAH clearances were analyzed by steady state method with permanent infusion and 3 to 4 urine collection periods 3 days later. The endogeneous creatinine clearance was determined within the same periods. The 99m Tc-DTPA slope clearance corresponded to the inulin clearance, as well as the hippurate clearance to the PAH clearance. The high filtration fraction calculated from nuclear medicine and chemical clearance methods and the low PAH extraction (42%) let suggest that PAH and hippurate are eliminated only incompletely from plasma in rat kidney and are unsuitable for determination of renal blood supply in rats. The creatinine clearance with 4.7 ± 1.38 μl · s -1 (100 g b-w) -1 was far beneath the clearance of inulin and 99m Tc-DTPA, supposing that creatinine is reabsorbed tubularly in part and the creatinine clearance can not be used for valuation of the GFR in rats. However, for this the 99m Tc-DTPA clearance in Wistar rats seems to be well suited. (author)

  10. Areva At December 31, 2010: Revenue rises to euros 9.104 bn: + 6.7% Backlog rises to euros 44.2 bn: + 2.0%; Areva au 31 decembre 2010: Croissance du chiffre d'affaires a 9104 Meuros: + 6,7 % Croissance du carnet de commandes a 44,2 Mdseuros: + 2,0 %

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2011-07-01

    In 2010, AREVA's consolidated revenue rose 6.7% to 9.104 billion euros (+ 5.1% growth like-for-like) compared with 2009. The Mining-Front End Business Group and the Reactors and Services Business Group were the leading growth engines, with revenue growth of 6.7% and 8.9% respectively. Foreign exchange had a positive impact of 141 million euros and the scope of consolidation remained stable over the period. Fourth quarter 2010 revenue totaled 2.936 billion euros, an increase of 7.7% (+4.8% like-for-like) compared with the fourth quarter of 2009, due in particular to 18.1% growth in the Mining-Front End BG. Foreign exchange had an impact of 58 million euros over the period. The group's backlog came to 44.2 billion euros at December 31, 2010, up 2.0% in relation to December 31, 2009. The backlog grew in the Mining-Front End and Renewable Energies BGs. Installed Base Business operations held up well, replenishing the backlog for the Reactors and Services BG. The agreement with the Indian utility NPCIL concerning the construction of two EPR{sup TM} reactors and fuel cycle supply for 25 years was not recorded in the backlog at December 31, 2010. The change in the Back End BG's backlog reflects the implementation of contracts signed in previous years. Nearly one billion euros in letters of intent signed in 2010 with US utilities corresponding to pre-sold production from the future enrichment plant were not included in the Mining-Front End BG's backlog. The backlog of the Mining-Front End BG came to 28.902 billion euros at December 31, 2010, up 4% compared with the end of 2009. Contracts won in 2010 include: - the 10-year uranium supply contract with CGNPC for approximately 3.5 billion dollars; - several other multi-year contracts signed in the front end of the cycle with US and Asian utilities. For the full year of 2010, the Mining-Front End BG reported revenue of 3.704 billion euros, an increase of 6.7% on a reported basis and of 4.2% LFL. Foreign

  11. Clearance systems in the brain—implications for Alzheimer disease

    Science.gov (United States)

    Tarasoff-Conway, Jenna M.; Carare, Roxana O.; Osorio, Ricardo S.; Glodzik, Lidia; Butler, Tracy; Fieremans, Els; Axel, Leon; Rusinek, Henry; Nicholson, Charles; Zlokovic, Berislav V.; Frangione, Blas; Blennow, Kaj; Ménard, Joël; Zetterberg, Henrik; Wisniewski, Thomas; de Leon, Mony J.

    2015-01-01

    Accumulation of toxic protein aggregates—amyloid-β (Aβ) plaques and hyperphosphorylated tau tangles—is the pathological hallmark of Alzheimer disease (AD). Aβ accumulation has been hypothesized to result from an imbalance between Aβ production and clearance; indeed, Aβ clearance seems to be impaired in both early and late forms of AD. To develop efficient strategies to slow down or halt AD, it is critical to understand how Aβ is cleared from the brain. Extracellular Aβ deposits can be removed from the brain by various clearance systems, most importantly, transport across the blood–brain barrier. Findings from the past few years suggest that astroglial-mediated interstitial fluid (ISF) bulk flow, known as the glymphatic system, might contribute to a larger portion of extracellular Aβ (eAβ) clearance than previously thought. The meningeal lymphatic vessels, discovered in 2015, might provide another clearance route. Because these clearance systems act together to drive eAβ from the brain, any alteration to their function could contribute to AD. An understanding of Aβ clearance might provide strategies to reduce excess Aβ deposits and delay, or even prevent, disease onset. In this Review, we describe the clearance systems of the brain as they relate to proteins implicated in AD pathology, with the main focus on Aβ. PMID:26195256

  12. Clearance systems in the brain-implications for Alzheimer disease.

    Science.gov (United States)

    Tarasoff-Conway, Jenna M; Carare, Roxana O; Osorio, Ricardo S; Glodzik, Lidia; Butler, Tracy; Fieremans, Els; Axel, Leon; Rusinek, Henry; Nicholson, Charles; Zlokovic, Berislav V; Frangione, Blas; Blennow, Kaj; Ménard, Joël; Zetterberg, Henrik; Wisniewski, Thomas; de Leon, Mony J

    2015-08-01

    Accumulation of toxic protein aggregates-amyloid-β (Aβ) plaques and hyperphosphorylated tau tangles-is the pathological hallmark of Alzheimer disease (AD). Aβ accumulation has been hypothesized to result from an imbalance between Aβ production and clearance; indeed, Aβ clearance seems to be impaired in both early and late forms of AD. To develop efficient strategies to slow down or halt AD, it is critical to understand how Aβ is cleared from the brain. Extracellular Aβ deposits can be removed from the brain by various clearance systems, most importantly, transport across the blood-brain barrier. Findings from the past few years suggest that astroglial-mediated interstitial fluid (ISF) bulk flow, known as the glymphatic system, might contribute to a larger portion of extracellular Aβ (eAβ) clearance than previously thought. The meningeal lymphatic vessels, discovered in 2015, might provide another clearance route. Because these clearance systems act together to drive eAβ from the brain, any alteration to their function could contribute to AD. An understanding of Aβ clearance might provide strategies to reduce excess Aβ deposits and delay, or even prevent, disease onset. In this Review, we describe the clearance systems of the brain as they relate to proteins implicated in AD pathology, with the main focus on Aβ.

  13. Secretin enhances [14C]erythritol clearance in unanesthetized dogs

    International Nuclear Information System (INIS)

    Lewis, M.H.; Baker, A.L.; Dhorajiwala, J.; Moossa, A.R.

    1982-01-01

    To determine the effect of secretin infusion on clearance of inert markers into bile, unanesthetized dogs fitted with Thomas cannulas received continuous infusions of [ 14 C]erythritol and [ 3 H]inulin throughout study. Taurocholic acid administered sequentially at 9.0, 20.0, and 40.0 mumol/min enhanced [ 14 C]erythritol clearance, and GIH secretin (3 units/min) administered along with TCA (40.0 mumol/min) increased [ 14 C]erythritol clearance from 4.9 +/- 1.2 ml/10 min to 6.8 +/- 1.3 ml/10 min (P less than 0.001), but simultaneously measured [ 3 H]inulin clearance was unaltered. Secretin alone also increased [ 14 C]erythritol clearance but did not alter [ 3 H]inulin clearance. The increase in [ 14 C]erythritol clearance per unit increase in bile flow was less during secretin infusion than TCA. Thus, secretin increases [ 14 C]erythritol transport through restricted channels, probably distal to the canaliculi. [ 14 C]Erythritol may not be an accurate marker for canalicular bile flow in dogs during secretin infusion

  14. Comparison of renal clearance of 99mTc-DTPA and inulin 131I-hippurate and PAH as well as creatinine clearance in Wistar-rats

    International Nuclear Information System (INIS)

    Hagemann, J.; Li Min Su; Strangfeld, D.; Schuerer, M.; Siewert, H.; Pietsch, R.; Kruse, I.; Priem, F.

    1988-01-01

    Averages and standard deviations of 99m Tc-DTPA and 131 I-hippurate slope clearance were consecutively determined for 56 male Wistar rats, with a body-weight of 271 ± 69 g in a single investigation. Clearance of 99m Tc-DTPA was 17.4 ± 3.4, that of 131 I-hippurate was 34.3 ± 7.2 μl · s -1 per 100 g body weight. For 17 rats inulin and PAH clearances were determined after 3 days with the steady-state method with continuous infusion and 3-4 periods of urine collection. During the same periods endogeneous creatinine clearance was determined. 99m Tc-DTPA slope clearance correlated well with inulin clearance, also the hippurate with the PAH clearance. The high values of the filtration fraction, calculated from radioisotope and chemical methods, and the low PAH extraction of 42% lead to the conclusion, that PAH and hippurate are incompletely eliminated by the rat kidney from plasma and therefore are inadequate for determining renal blood flow in rats. Creatinine clearance was 4.7 ± 1.38 μl · s -1 per 100 g body weight, much lower than that of inulin and 99m Tc-DTPA. Therefore is assumed, that tubular reabsorption of creatinine occurs and creatinine clearance cannot serve for the evaluation of GFR in rats. For this, however, the clearance of 99m Tc-DTPA seems well applicable in Wistar rats. (author)

  15. Physical security of nuclear facilities

    International Nuclear Information System (INIS)

    Dixon, H.

    1987-01-01

    A serious problem with present security systems at nuclear facilities is that the threats and standards prepared by the NRC and DOE are general, and the field offices are required to develop their own local threats and, on that basis, to prepared detailed specifications for security systems at sites in their jurisdiction. As a result, the capabilities of the systems vary across facilities. Five steps in particular are strongly recommended as corrective measures: 1. Those agencies responsible for civil nuclear facilities should jointly prepare detailed threat definitions, operational requirements, and equipment specifications to protect generic nuclear facilities, and these matters should be issued as policy. The agencies should provide sufficient detail to guide the design of specific security systems and to identify candidate components. 2. The DOE, NRC, and DOD should explain to Congress why government-developed security and other military equipment are not used to upgrade existing security systems and to stock future ones. 3. Each DOE and NRC facility should be assessed to determine the impact on the size of the guard force and on warning time when personnel-detecting radars and ground point sensors are installed. 4. All security guards and technicians should be investigated for the highest security clearance, with reinvestigations every four years. 5. The processes and vehicles used in intrafacility transport of nuclear materials should be evaluated against a range of threats and attack scenarios, including violent air and vehicle assaults. All of these recommendations are feasible and cost-effective. The appropriate congressional subcommittees should direct that they be implemented as soon as possible

  16. Metabolic clearance rate and urinary clearance of purified beta-core

    International Nuclear Information System (INIS)

    Wehmann, R.E.; Blithe, D.L.; Flack, M.R.; Nisula, B.C.

    1989-01-01

    We injected a highly purified preparation of the beta-core molecule, a fragment of hCG beta excreted in pregnancy urine, into five men and three women to determine its kinetic parameters, MCR, and urinary clearance. The beta-core molecule was distributed in an initial volume [1950 +/- 156 (mean +/- SEM) mL/m2 body surface area] approximately equal to the estimated plasma volume. Its disappearance was multiexponential on a semilogarithmic plot, with a rapid phase t1/2 of 3.5 +/- 0.7 min and a slow phase t1/2 of 22.4 +/- 4.2 min. The transit time (the mean time spent by a molecule of beta-core in transit) was 20.6 +/- 2.1 min. The MCR was 192.0 +/- 8.0 mL/min.m2 body surface area. About 5% of the injected dose of beta-core was excreted into the urine in the first 30 min after injection, and low levels of excretion persisted for up to 7 days. The urinary clearance rate of beta-core was 13.7 +/- 1.4 mL/min.m2, accounting for about 8% of the elimination of beta-core from the plasma. The beta-core immunoreactivity in serum and urine was characterized by gel filtration and three independent RIA systems to show that its properties were indistinguishable from those of the injected beta-core. Serum levels of beta-core in pregnant women were less than 0.2 ng/mL, while the amounts excreted in their urine were as much as 5 mg/day. Based on these clearance parameters of beta-core in normal subjects, less than 0.2% of the beta-core excreted in pregnancy urine is derived by urinary clearance of plasma beta-core. Therefore, more than 99% of the beta-core excreted in pregnancy urine is derived from beta-core in a compartment separate from plasma. In particular, these data indicate that there is relatively little placental secretion of beta-core into plasma and that placental secretion does not account for the vast majority of beta-core in pregnancy urine

  17. Department of Energy security program needs effective information systems

    International Nuclear Information System (INIS)

    1991-10-01

    Although security is an important, nearly billion-dollar-a-year function in the Department of Energy (DOE), key information systems that hold important data about security weaknesses and incidents have limited analytical capabilities and contain unreliable information. The resultant difficulty in identifying patterns and trends reduces managers' ability to ensure the effectiveness of the security program. Resources are also wasted because DOE has deployed incompatible systems that are unable to electronically share or transfer data, often forcing employees to manually re-enter data that are already stored in computers elsewhere. Finally, continuing data problems with other important security information systems, such as those used to track security clearances and classified documents, indicate that information system deficiencies are extensive. A major reason for these problems is that DOE has not done a comprehensive, strategic assessment of its information and information technology needs of the security program. DOE's efforts are fragmented because it has not assigned to any organization the leadership responsibility to determine security information needs and to plan and manage security information resources Department-wide. This paper reports that a number of changes are needed to correct these problems and take advantage of information technology to help strengthen the security program

  18. Allometric scaling for predicting human clearance of bisphenol A

    International Nuclear Information System (INIS)

    Collet, Séverine H.; Picard-Hagen, Nicole; Lacroix, Marlène Z.; Puel, Sylvie; Viguié, Catherine; Bousquet-Melou, Alain; Toutain, Pierre-Louis; Gayrard, Véronique

    2015-01-01

    The investigation of interspecies differences in bisphenol A (BPA) pharmacokinetics (PK) may be useful for translating findings from animal studies to humans, identifying major processes involved in BPA clearance mechanisms, and predicting BPA PK parameters in man. For the first time, a large range of species in terms of body weight, from 0.02 kg (mice) to 495 kg (horses) was used to predict BPA clearance in man by an allometric approach. BPA PK was evaluated after intravenous administration of BPA in horses, sheep, pigs, dogs, rats and mice. A non-compartmental analysis was used to estimate plasma clearance and steady state volume of distribution and predict BPA PK parameters in humans from allometric scaling. In all the species investigated, BPA plasma clearance was high and of the same order of magnitude as their respective hepatic blood flow. By an allometric scaling, the human clearance was estimated to be 1.79 L/min (equivalent to 25.6 mL/kg.min) with a 95% prediction interval of 0.36 to 8.83 L/min. Our results support the hypothesis that there are highly efficient and hepatic mechanisms of BPA clearance in man. - Highlights: • Allometric scaling was used to predict BPA pharmacokinetic parameters in humans. • In all species, BPA plasma clearance approached hepatic blood flow. • Human BPA clearance was estimated to be 1.79 L/min

  19. Allometric scaling for predicting human clearance of bisphenol A

    Energy Technology Data Exchange (ETDEWEB)

    Collet, Séverine H., E-mail: s.collet@envt.fr; Picard-Hagen, Nicole, E-mail: n.hagen-picard@envt.fr; Lacroix, Marlène Z., E-mail: m.lacroix@envt.fr; Puel, Sylvie, E-mail: s.puel@envt.fr; Viguié, Catherine, E-mail: c.viguie@envt.fr; Bousquet-Melou, Alain, E-mail: a.bousquet-Melou@envt.fr; Toutain, Pierre-Louis, E-mail: pltoutain@wanadoo.fr; Gayrard, Véronique, E-mail: v.gayrard@envt.fr

    2015-05-01

    The investigation of interspecies differences in bisphenol A (BPA) pharmacokinetics (PK) may be useful for translating findings from animal studies to humans, identifying major processes involved in BPA clearance mechanisms, and predicting BPA PK parameters in man. For the first time, a large range of species in terms of body weight, from 0.02 kg (mice) to 495 kg (horses) was used to predict BPA clearance in man by an allometric approach. BPA PK was evaluated after intravenous administration of BPA in horses, sheep, pigs, dogs, rats and mice. A non-compartmental analysis was used to estimate plasma clearance and steady state volume of distribution and predict BPA PK parameters in humans from allometric scaling. In all the species investigated, BPA plasma clearance was high and of the same order of magnitude as their respective hepatic blood flow. By an allometric scaling, the human clearance was estimated to be 1.79 L/min (equivalent to 25.6 mL/kg.min) with a 95% prediction interval of 0.36 to 8.83 L/min. Our results support the hypothesis that there are highly efficient and hepatic mechanisms of BPA clearance in man. - Highlights: • Allometric scaling was used to predict BPA pharmacokinetic parameters in humans. • In all species, BPA plasma clearance approached hepatic blood flow. • Human BPA clearance was estimated to be 1.79 L/min.

  20. The changing face of Hanford security 1990--1994

    International Nuclear Information System (INIS)

    Thielman, J.

    1995-01-01

    The meltdown of the Cold War was a shock to the systems built to cope with it. At the DOE's Hanford Site in Washington State, a world-class safeguards and security system was suddenly out of step with the times. The level of protection for nuclear and classified materials was exceptional. But the cost was high and the defense facilities that funded security were closing down. The defense mission had created an umbrella of security over the sprawling Hanford Site. Helicopters designed to ferry special response teams to any trouble spot on the 1,456 square-kilometer site made the umbrella analogy almost literally true. Facilities were grouped into areas, fenced off like a military base, and entrance required a badge check for everyone. Within the fence, additional rings of protection were set up around security interests or targets. The security was effective, but costly to operate and inconvenient for employees and visitors alike. Moreover, the umbrella meant that virtually all employees needed a security clearance just to get to work, whether they worked on classified or unclassified projects. Clearly, some fundamental rethinking of safeguards and security was needed. The effort to meet that challenge is the story of transition at Hanford and documented here

  1. 48 CFR 2452.237-75 - Clearance of contractor personnel.

    Science.gov (United States)

    2010-10-01

    ... 48 Federal Acquisition Regulations System 6 2010-10-01 2010-10-01 true Clearance of contractor... Clauses 2452.237-75 Clearance of contractor personnel. As prescribed in 2437.110(e), insert the following clause in solicitations and contracts. Clearance of Contractor Personnel (OCT 1999) (a) General. This...

  2. Comparative evaluation of iohexol and inulin clearance for glomerular filtration rate determinations

    International Nuclear Information System (INIS)

    Lindblad, H.G.; Berg, U.B.

    1994-01-01

    The authors have evaluated iohexol as a filtration marker in 150 children. The clearance of iohexol was compared with that of inulin or with a formula clearance. The single-sample clearance of iohexol showed a good correlation with the clearance of inulin. The clearance of iohexol correlated well with the formula clearance. The optimal blood sampling time for iohexol clearance determinations appears to be between 120 and 180 min after injection, at least in patient with relatively normal filtration rates. It is concluded that iohexol clearance is an accurate method of determining the glomerular filtration rate in clinical practice. 25 refs., 5 figs

  3. Centrifugal compressor tip clearance and impeller flow

    Energy Technology Data Exchange (ETDEWEB)

    Jaatinen-Varri, Ahti; Tiainen, Jonna; Turunen-Saaresti, Teemu; Gronman, Aki; Ameli, Alireza; Backman, Jari [Laboratory of Fluid Dynamics, LUT School of Energy Systems, Lappeenranta University of Technology, Lappeenranta (Finland); Engeda, Abraham [Turbomachinery Laboratory, Dept. of Mechanical Engineering, Michigan State University, East Lansing (United States)

    2016-11-15

    Compressors consume a considerable portion of the electricity used in the industrial sector. Hence, improvements in compressor efficiency lead to energy savings and reduce environmental impacts. The efficiency of an unshrouded centrifugal compressor suffers from leakage flow over the blade tips. The effect of tip leakage flow on the passage flow differs between the full and splitter blade passages. In this study, the differences in the flow fields between the full and splitter blade passages were studied numerically in detail. An industrial high-speed compressor with a design pressure ratio of 1.78 was modelled. Numerical studies were conducted with six different tip clearances and three different diffuser widths. The results show that increasing tip clearance considerably increases the reversed flow into the impeller with an unpinched diffuser. The reversed flow then partly mixes into the flow in the same blade passage it entered the impeller and the rest migrates over the blade, mixing with the tip clearance flow. Furthermore, as the reversed and clearance flow mix into the wake, the wake is weakened. As pinch reduces both the reversed flow and clearance flow, the passage wakes are stronger with pinches. However, the pinch is beneficial as the losses at the impeller outlet decrease.

  4. Centrifugal compressor tip clearance and impeller flow

    International Nuclear Information System (INIS)

    Jaatinen-Varri, Ahti; Tiainen, Jonna; Turunen-Saaresti, Teemu; Gronman, Aki; Ameli, Alireza; Backman, Jari; Engeda, Abraham

    2016-01-01

    Compressors consume a considerable portion of the electricity used in the industrial sector. Hence, improvements in compressor efficiency lead to energy savings and reduce environmental impacts. The efficiency of an unshrouded centrifugal compressor suffers from leakage flow over the blade tips. The effect of tip leakage flow on the passage flow differs between the full and splitter blade passages. In this study, the differences in the flow fields between the full and splitter blade passages were studied numerically in detail. An industrial high-speed compressor with a design pressure ratio of 1.78 was modelled. Numerical studies were conducted with six different tip clearances and three different diffuser widths. The results show that increasing tip clearance considerably increases the reversed flow into the impeller with an unpinched diffuser. The reversed flow then partly mixes into the flow in the same blade passage it entered the impeller and the rest migrates over the blade, mixing with the tip clearance flow. Furthermore, as the reversed and clearance flow mix into the wake, the wake is weakened. As pinch reduces both the reversed flow and clearance flow, the passage wakes are stronger with pinches. However, the pinch is beneficial as the losses at the impeller outlet decrease

  5. Hepatic drug clearance following traumatic injury.

    Science.gov (United States)

    Slaughter, R L; Hassett, J M

    1985-11-01

    Trauma is a complex disease state associated with physiologic changes that have the potential to alter hepatic drug clearance mechanisms. These responses include alterations in hepatic blood flow, reduction in hepatic microsomal activity, reduction in hepatic excretion processes, and changes in protein binding. Hepatic blood flow is influenced by sympathomimetic activity. Both animal and human studies demonstrate an initial reduction and subsequent increase in hepatic blood flow, which coincides with an observed increase and subsequent return to normal in serum catecholamine concentrations. Unfortunately, there are no human studies that address the importance these findings may have to the clearance processes of high intrinsic clearance compounds. Animal studies of trauma indicate that hepatic microsomal activity is depressed during the post-traumatic period. Reduction in the hepatic clearance of antipyrine, a model low intrinsic compound, has also been demonstrated in animal models of trauma. In addition to these effects, hepatic excretion of substances such as indocyanine green and bilirubin have been demonstrated to be impaired in both traumatized animals and humans. Finally, substantial increases in the serum concentration of the binding protein alpha 1-acid glycoprotein occur in trauma patients. This has been reported to be associated with subsequent decreases in the free fraction of lidocaine and quinidine. In addition to changing serum drug concentration/response relationships, the pharmacokinetic behavior of drugs bound to alpha 1-acid glycoprotein should also change. Preliminary observations in our laboratory in a dog model of surgically-induced trauma have shown a reduction in the total clearance of lidocaine and reduction in free lidocaine concentration.(ABSTRACT TRUNCATED AT 250 WORDS)

  6. Diminished creatinine clearance in anorexia nervosa: reversal with weight gain.

    OpenAIRE

    Boag, F; Weerakoon, J; Ginsburg, J; Havard, C W; Dandona, P

    1985-01-01

    To assess whether patients with anorexia nervosa have abnormalities in creatinine clearance, we measured plasma creatinine concentration, urinary creatinine excretion, and creatinine clearance in 10 patients with anorexia nervosa before and during treatment. Urinary creatinine excretion and creatinine clearance were diminished in all patients. Nine patients had significant decreases in their plasma creatinine and creatinine clearance was increased even when corrected for body weight and body ...

  7. Cerebrospinal Fluid Clearance in Alzheimer Disease Measured with Dynamic PET.

    Science.gov (United States)

    de Leon, Mony J; Li, Yi; Okamura, Nobuyuki; Tsui, Wai H; Saint-Louis, Les A; Glodzik, Lidia; Osorio, Ricardo S; Fortea, Juan; Butler, Tracy; Pirraglia, Elizabeth; Fossati, Silvia; Kim, Hee-Jin; Carare, Roxana O; Nedergaard, Maiken; Benveniste, Helene; Rusinek, Henry

    2017-09-01

    Evidence supporting the hypothesis that reduced cerebrospinal fluid (CSF) clearance is involved in the pathophysiology of Alzheimer disease (AD) comes primarily from rodent models. However, unlike rodents, in which predominant extracranial CSF egress is via olfactory nerves traversing the cribriform plate, human CSF clearance pathways are not well characterized. Dynamic PET with 18 F-THK5117, a tracer for tau pathology, was used to estimate the ventricular CSF time-activity as a biomarker for CSF clearance. We tested 3 hypotheses: extracranial CSF is detected at the superior turbinates; CSF clearance is reduced in AD; and CSF clearance is inversely associated with amyloid deposition. Methods: Fifteen subjects, 8 with AD and 7 normal control volunteers, were examined with 18 F-THK5117. Ten subjects additionally underwent 11 C-Pittsburgh compound B ( 11 C-PiB) PET scanning, and 8 were 11 C-PiB-positive. Ventricular time-activity curves of 18 F-THK5117 were used to identify highly correlated time-activity curves from extracranial voxels. Results: For all subjects, the greatest density of CSF-positive extracranial voxels was in the nasal turbinates. Tracer concentration analyses validated the superior nasal turbinate CSF signal intensity. AD patients showed ventricular tracer clearance reduced by 23% and 66% fewer superior turbinate CSF egress sites. Ventricular CSF clearance was inversely associated with amyloid deposition. Conclusion: The human nasal turbinate is part of the CSF clearance system. Lateral ventricle and superior nasal turbinate CSF clearance abnormalities are found in AD. Ventricular CSF clearance reductions are associated with increased brain amyloid depositions. These data suggest that PET-measured CSF clearance is a biomarker of potential interest in AD and other neurodegenerative diseases. © 2017 by the Society of Nuclear Medicine and Molecular Imaging.

  8. Analysis of conservativity analysis for clearance levels. Final report

    International Nuclear Information System (INIS)

    Deckert, A.; Thierfeldt, S.

    1997-07-01

    When deriving clearance levels for material from nuclear installations it is necessary to proceed with a certain degree of conservativity. This can, however, differ between various sets of clearance levels leading to inconsistencies between clearance pathways. The aim of the work therefore is to compare levels of conservativity for the following two sets of clearance levels: clearance levels for disposal as conventional waste and for metallic materials for recycling/reuse. A method was developed to quantify the degree of conservativity and make it comparable. The actual and future situation for disposal of (conventional) wastes in Germany was analysed. In addition, the masses, nuclide vectors, geographical distribution etc. for slightly radioactive material being cleared for conventional disposal was analysed and modelled and the resulting dose distributions were calculated. The values for the clearance levels were taken from the 1995 recommendation by the German Commission on Radiation Protection (SSK). By using realistic scenarios, the exposure was calculated for the personnel on the landfills and for persons of the general public being exposed via groundwater pathways. It could be shown that the trivial dose range will not be exceeded even if the masses of cleared material per landfill site exceed 100 Mg/a. Because of the types and distribution of nuclear installations in Germany and because of the nuclide vectors it is therefore not necessary to limit the masses per landfill sites. Clearance levels that are determined by the exposure pathways external exposure to and the inhalation of dust by the landfill personnel show a similar level of conservativity as those for metal scrap. This means that the clearance levels for gamma emitting nuclides are not overly restrictive. Although radiologically justified, raising the clearance levels would not lead to an increase of the material quantities because other nuclides of the respective nuclide vectors are limiting. In

  9. Numerical investigation of hub clearance flow in a Kaplan turbine

    Science.gov (United States)

    Wu, H.; Feng, J. J.; Wu, G. K.; Luo, X. Q.

    2012-11-01

    In this paper, the flow field considering the hub clearance flow in a Kaplan turbine has been investigated through using the commercial CFD code ANSYS CFX based on high-quality structured grids generated by ANSYS ICEM CFD. The turbulence is simulated by k-ω based shear stress transport (SST) turbulence model together with automatic near wall treatments. Four kinds of simulations have been conducted for the runner geometry without hub clearance, with only the hub front clearance, with only the rear hub clearance, and with both front and rear clearance. The analysis of the obtained results is focused on the flow structure of the hub clearance flow, the effect on the turbine performance including hydraulic efficiency and cavitation performance, which can improve the understanding on the flow field in a Kaplan turbine.

  10. Numerical investigation of hub clearance flow in a Kaplan turbine

    International Nuclear Information System (INIS)

    Wu, H; Feng, J J; Wu, G K; Luo, X Q

    2012-01-01

    In this paper, the flow field considering the hub clearance flow in a Kaplan turbine has been investigated through using the commercial CFD code ANSYS CFX based on high-quality structured grids generated by ANSYS ICEM CFD. The turbulence is simulated by k-ω based shear stress transport (SST) turbulence model together with automatic near wall treatments. Four kinds of simulations have been conducted for the runner geometry without hub clearance, with only the hub front clearance, with only the rear hub clearance, and with both front and rear clearance. The analysis of the obtained results is focused on the flow structure of the hub clearance flow, the effect on the turbine performance including hydraulic efficiency and cavitation performance, which can improve the understanding on the flow field in a Kaplan turbine.

  11. Determination of renal clearance of 131I-hippuran

    International Nuclear Information System (INIS)

    Ridzon, S.

    1982-01-01

    The author presents his own method for the determination of total renal clearance of 131 I-hippuran under conditions of its diminishing plasma concentration following single intravenous administration. Total renal clearance is determined as the ratio of the amount of activity excreted into the urine over a certain time interval and of the area limited by the curve of activity decrease in plasma and by the time axis in the corresponding interval. The results are demonstrated in five investigated healthy subjects, and very good agreement of the calculated values of total renal clearance for different time intervals in the same subject is pointed out. When isotope nephrography is simultaneously performed, the method allows to determine also the values of isolated renal clearance for each kidney separately. (author)

  12. Airway Clearance Techniques (ACTs)

    Medline Plus

    Full Text Available ... Research Consortia CF Biomarker Consortium CFTR 3-D Structure Consortium CFTR Folding Consortium Epithelial Stem Cell Consortium Mucociliary Clearance Consortium SUCCESS WITH THERAPIES RESEARCH ...

  13. Inherited Disorders of Bilirubin Clearance

    Science.gov (United States)

    Memon, Naureen; Weinberger, Barry I; Hegyi, Thomas; Aleksunes, Lauren M

    2016-01-01

    Inherited disorders of hyperbilirubinemia may be caused by increased bilirubin production or decreased bilirubin clearance. Reduced hepatic bilirubin clearance can be due to defective 1) unconjugated bilirubin uptake and intrahepatic storage, 2) conjugation of glucuronic acid to bilirubin (e.g. Gilbert syndrome, Crigler-Najjar syndrome, Lucey-Driscoll syndrome, breast milk jaundice), 3) bilirubin excretion into bile (Dubin-Johnson syndrome), or 4) conjugated bilirubin re-uptake (Rotor syndrome). In this review, the molecular mechanisms and clinical manifestations of these conditions are described, as well as current approaches to diagnosis and therapy. PMID:26595536

  14. Approaches towards establishing of clearance levels in Japan

    International Nuclear Information System (INIS)

    Sumitani, N.; Watanabe, I.; Okoshi, M.

    1998-01-01

    It is important to establish necessary regulatory systems for decommissioning waste management, especially to establish clearance levels from regulatory control. To establish the regulatory systems, the Nuclear Safety Commission (NSC) has been discussing the unconditional clearance levels for materials from nuclear reactors since May 1997. The NSC tries to derive unconditional clearance levels for the materials such as concrete and ferrous metal, arising from nuclear reactor decommissioning. In the derivation, both disposal and recycle/reuse of the materials are considered. Typical scenarios and parameter values for dose estimation are selected considering the Japanese natural and social conditions. Preliminary clearance levels were derived from 10 μSv/yr of individual dose criterion and deterministic analysis. For most radionuclides, the preliminary results are the same order of magnitude recommended in IAEA-TECDOC-855. Some radionuclides such as β emitters, however, are different order of magnitude from those recommended in IAEA-TECDOC-855. It is necessary that international organizations lead the discussions on the clearance levels to conclude final consensus. (author)

  15. Green technology; only Forest Clearance is needed

    Indian Academy of Sciences (India)

    First page Back Continue Last page Graphics. How was Forest Clearance granted before the procedures for constitution of ESZ was completed? How was Forest Clearance granted before the procedures for constitution of ESZ was completed? How was land in Murmurwadi still under litigation made available? How was ...

  16. Airway Clearance Techniques (ACTs)

    Medline Plus

    Full Text Available ... Cell Consortium Mucociliary Clearance Consortium SUCCESS WITH THERAPIES RESEARCH CONSORTIUM Therapeutics Development Network TDN Coordinating Center Study Services Working With the TDN Tools and Resources ...

  17. Airway Clearance Techniques (ACTs)

    Medline Plus

    Full Text Available ... 3-D Structure Consortium CFTR Folding Consortium Epithelial Stem Cell Consortium Mucociliary Clearance Consortium SUCCESS WITH THERAPIES RESEARCH CONSORTIUM Therapeutics Development Network TDN Coordinating Center ...

  18. A study for promoting measures of social acceptance on clearance system

    International Nuclear Information System (INIS)

    Okoshi, Minoru; Torii, Hiroyuki; Fujii, Yasuhiko

    2007-01-01

    Clearance is one of the useful concepts to manage large amounts of slightly contaminated solid radioactive materials generated from the decommissioning of nuclear facilities. Cleared materials are expected to be disposed of as conventional wastes or recycled to produce consumer goods. In Japan, the legal frame-work for clearance was established in 2005 by amending the Law to regulate nuclear materials, reactors and so on. However, it is not so clear whether the general public understands clearance well. In this paper, major concerns about clearance from the general public are analyzed based on the public comments for reports on clearance prepared by the Nuclear Safety Commission and the Nuclear Institute Safety Agency. The major anxieties for clearance expressed by the general public are the safety of clearance, unknown factors of radiation effects, possibilities of excess radiation exposure due to inadequate measurements of radioactivities and fairness in decision making. In order to deal with those anxieties, some countermeasures including the confidence in nuclear operators and regulatory authorities and controllability of clearance by the general public are discussed to promote the social acceptance of clearance by the general public. (author)

  19. Airway Clearance Techniques (ACTs)

    Medline Plus

    Full Text Available ... 3-D Structure Consortium CFTR Folding Consortium Epithelial Stem Cell Consortium Mucociliary Clearance Consortium SUCCESS WITH THERAPIES RESEARCH CONSORTIUM Therapeutics Development Network TDN Coordinating Center Study ...

  20. Intraarticular volume and clearance in human synovial effusions

    International Nuclear Information System (INIS)

    Wallis, W.J.; Simkin, P.A.; Nelp, W.B.; Foster, D.M.

    1985-01-01

    Intraarticular volumes were measured by radiolabeled albumin (RISA) distribution in chronic knee effusions from 11 rheumatoid arthritis patients and 9 osteoarthritis patients. Volumes of synovial fluid obtained at joint aspiration were substantially less than those found by RISA dilution. Up to 24 hours was needed for full distribution of RISA throughout the intraarticular compartment. Measured 123I and RISA radioactivity over the knee described monoexponential rate constants, lambda (minute-1). The clearance of 123I and RISA from synovial effusions was derived by the formulation volume (ml) X lambda (minute-1) = clearance (ml/minute). RISA clearance in rheumatoid effusions was significantly greater than that found in osteoarthritis effusions. Intraarticular volume and isotope clearance were easily quantified and provide measures for further evaluating the microvascular physiology of synovial effusions

  1. Test Rig for Evaluating Active Turbine Blade Tip Clearance Control Concepts

    Science.gov (United States)

    Lattime, Scott B.; Steinetz, Bruce M.; Robbie, Malcolm G.

    2003-01-01

    Improved blade tip sealing in the high pressure compressor and high pressure turbine can provide dramatic improvements in specific fuel consumption, time-on-wing, compressor stall margin and engine efficiency as well as increased payload and mission range capabilities of both military and commercial gas turbine engines. The preliminary design of a mechanically actuated active clearance control (ACC) system for turbine blade tip clearance management is presented along with the design of a bench top test rig in which the system is to be evaluated. The ACC system utilizes mechanically actuated seal carrier segments and clearance measurement feedback to provide fast and precise active clearance control throughout engine operation. The purpose of this active clearance control system is to improve upon current case cooling methods. These systems have relatively slow response and do not use clearance measurement, thereby forcing cold build clearances to set the minimum clearances at extreme operating conditions (e.g., takeoff, re-burst) and not allowing cruise clearances to be minimized due to the possibility of throttle transients (e.g., step change in altitude). The active turbine blade tip clearance control system design presented herein will be evaluated to ensure that proper response and positional accuracy is achievable under simulated high-pressure turbine conditions. The test rig will simulate proper seal carrier pressure and temperature loading as well as the magnitudes and rates of blade tip clearance changes of an actual gas turbine engine. The results of these evaluations will be presented in future works.

  2. The tear turnover and tear clearance tests - a review.

    Science.gov (United States)

    Garaszczuk, Izabela K; Montes Mico, Robert; Iskander, D Robert; Expósito, Alejandro Cerviño

    2018-03-01

    The aim is to provide a summary of methods available for the assessment of tear turnover and tear clearance rates. The review defines tear clearance and tear turnover and describes their implication for ocular surface health. Additionally, it describes main types of techniques for measuring tear turnover, including fluorescein tear clearance tests, techniques utilizing electromagnetic spectrum and tracer molecule and novel experimental techniques utilizing optical coherence tomography and fluorescein profilometry. Areas covered: Internet databases (PubMed, Science Direct, Google Scholar) and most frequently cited references were used as a principal resource of information on tear turnover rate and tear clearance rate, presenting methodologies and equipment, as well as their definition and implications for the anterior eye surface health and function. Keywords used for data-search were as follows: tear turnover, tear clearance, fluorescein clearance, scintigraphy, fluorophotometry, tear flow, drainage, tear meniscus dynamics, Krehbiel flow and lacrimal functional unit. Expert commentary: After decades, the topic of tear turnover assessment has been reintroduced. Recently, new techniques have been developed to propose less invasive, less time consuming and simpler methodologies for the assessment of tear dynamics that have the potential to be utilized in clinical practice.

  3. Airway Clearance Techniques (ACTs)

    Medline Plus

    Full Text Available ... Community in Health Care Reform Milestones in Health Care Reform How Tax Reform Could Impact People With CF The ... Home Life With CF Treatments and Therapies Airway Clearance ...

  4. Act of 4 August 1955 concerning State Security in the Nuclear Field

    International Nuclear Information System (INIS)

    1955-01-01

    This Act governing State security in the nuclear field lays down that the King may determine the security measures to be complied with concerning nuclear research, materials, methods of production used by establishments and legal or physical persons having in their possession information, documents or material obtained either directly from the Government or with its consent. The Act was supplemented by Royal Order of 14 March 1956 which amplified its provisions by laying down specific requirements regarding the classification of information and material, the security measures to be applied thereto, and to establishments involved in related research work. It also provides for the security clearance to be applied to persons who shall be authorised to obtain such information and classified material. A Royal Order of 18 October 1974 amends this Order in respect of the authorities responsible for its implementation. (NEA) [fr

  5. Effect of clearance on cartilage tribology in hip hemi-arthroplasty.

    Science.gov (United States)

    Lizhang, Jia; Taylor, Simon D; Jin, Zhongmin; Fisher, John; Williams, Sophie

    2013-12-01

    Hemi-arthroplasty of the hip (an artificial femoral head articulating against the natural acetabulum) is used to treat fractured necks of femur; however, there is evidence that articulation causes erosion of the cartilage, resulting in pain for the patient. Parameters that may influence this cartilage erosion include head material and roughness, clearance between the head and acetabulum and activity levels of the patient. This study has assessed the effect of clearance of hemi-arthroplasty articulations on the contact stress, friction and cartilage deformation in an in vitro tribological simulation of the hemi-arthroplasty joint that applied dynamic loads and motion. It has been demonstrated that peak contact stress increased from 5.6 to 10.6 MPa as radial clearance increased from small (1.8 mm). In all samples, friction factor increased with time and was significantly less with extra-large clearances compared to small (<0.6 mm), medium (0.6-1.2 mm) and large (1.2-1.8 mm) clearances. The cartilage deformation observed was significantly greater in acetabulum samples paired to give small or extra-large clearances compared to those with medium or large clearances.

  6. Modified Augmented Renal Clearance Score Predicts Rapid Piperacillin and Tazobactam Clearance in Critically Ill Surgery and Trauma Patients

    Science.gov (United States)

    2014-04-24

    collision; VAP , ventilator-associated pneumonia. TABLE 2. PK Parameter Estimates for Free Piperacillin and Tazobactam in Patients Stratified by ARC Score...SOFA score are typically generated during routine care of the most severely ill patients . Positive screening test results (high ARC scores) can be...Modified Augmented Renal Clearance score predicts rapid piperacillin and tazobactam clearance in critically ill surgery and trauma patients Kevin S

  7. A credit policy approach in a two-warehouse inventory model for deteriorating items with price- and stock-dependent demand under partial backlogging

    Science.gov (United States)

    Panda, Gobinda Chandra; Khan, Md. Al-Amin; Shaikh, Ali Akbar

    2018-04-01

    Advertisement of the product is an important factor in inventory analysis. Also, price and stock have an important role to attract more customers in the competitive business situations. Trade credit policy is another important role in inventory analysis. We have combined these three factors together in a two-warehouse inventory model and represented it mathematically. In addition, we have added deteriorating factor of our proposed problem with price- and stock-dependent demand under partial backlogged shortage and solved. The frequency of advertisement is considered constant for a year in this paper. The proposed model is highly nonlinear in nature. Due to highly nonlinearity, we could not find the closed form solution. In this paper, trade credit facility is taken in the perspective of retailer, and all the possible cases and subcases of the model are discussed and solved using lingo 10.0 software. The results of sensitivity analysis prove the effectiveness of the proposed model.

  8. Raconter les Highland Clearances : Fluctuations mémorielles et instrumentalisationde la mémoire

    Directory of Open Access Journals (Sweden)

    Laurence GOURIEVIDIS

    2011-06-01

    Full Text Available Dans l’histoire écossaise moderne, peu d’événements ont autant de résonance et de charge émotionnelle que les évictions des paysans du Nord du pays et les conflits qu’elles engendrèrent entre le milieu du 18ème siècle et 1886, année où une loi garantissant l’accès à la terre à une partie de la paysannerie concernée limita considérablement le droit des propriétaires et mit un terme aux expulsions massives. Connus sous le nom de Highland Clearances, ces événementsn’ont rien perdu de leur pouvoir mobilisateur. Les adjectifs « contesté », ou « controversé » leur sont couramment appliqués ainsi qu’à leurs représentations, qu’elles soient littéraires ou historiques. Cet article s’appuie sur la notion de « mémoire culturelle », développée par Jan Assman, pour analyser le sens, les valeurs et la vision du monde cristallisés dans la mémoire collective des Clearances. S’attachant à l’historiographie des Clearances, à la production littéraire sur la période et à son appropriation politique, il met en lumière la cohérence et la stabilité de la mémoire culturelle des Clearances. Ces dernières sont, par conséquent, devenues un symbole puissant dans le discours politique écossais ; Nationalistes et Travaillistes écossais s’en sont emparés pour alimenter des argumentaires en faveur de la réforme de la propriété foncière, de l’accès à la terre, en résumé la démocratisation du système foncier.In Modern Scottish history, few events have had as much resonance and emotional charge as the Highland Clearances, i.e. the evictions of tenants and the social conflicts in northern Scotland and the Hebrides from the middle of the 18th century until 1886, when legislation put an end to large-scale removals by conferring security of tenure on crofters and considerably restricting landowning power. The Highland Clearances still retain much of their mobilizing power. The adjectives

  9. Airway Clearance Techniques (ACTs)

    Medline Plus

    Full Text Available ... in CF Clinical Care Guidelines Cystic Fibrosis-Related Diabetes Clinical Care Guidelines Liver Disease Clinical Care Guidelines Respiratory Care Guidelines CF Airway Clearance Therapies Clinical Care Guidelines Chronic Medications to Maintain Lung ...

  10. Wind Power and Fault Clearance. Final Report

    Energy Technology Data Exchange (ETDEWEB)

    Vikesjoe, Johnny; Messing, Lars (Gothia Power (Sweden))

    2011-04-15

    The increased penetration of wind power will increase the impact of wind power on the grid and thereby increase the importance of a clear guidance concerning the requirements on the protection system of the wind power units and the grid protection in connection to wind power units. The protection system should be able to satisfy the grid connection requirements, set by the TSO (Transmission System Operator) and the grid owners, as well as the general safety and security requirements, such as; personal safety, operational security and economic insurance, i.e. an insurance against economic losses. Vindforsk has appointed Gothia Power AB to perform a study concerning the fault clearance function in connection to wind power installations. The study is divided into two parts; Part 1: The first stage of the project handled the present praxis for the protection, including investigation of legal requirements, operational requirement and personal safety requirement applicable to wind power applications. Proposals for protection requirement for wind power units and the connecting grid are given. Basically 'normal' fault clearance requirements regarding speed, selectivity and redundancy can be used also in applications in connection to wind power. Part 2: The second part of the project results in a guideline for design of protection systems in connection to wind power. In this report mainly part 2 is covered. The main focus is given to clearance of faults in the grid connecting the wind power plants. Regarding internal faults and critical operation states within the wind power plant, a short discussion of feasible protection functions is given. Some critical fault cases in the grid have been identified and discussed: - Undetected islanding and failure of reclosing. There can be a risk of undetected island operation. In such cases it is recommended to use controlled autoreclosing in the vicinity of wind power generation. - Unwanted disconnection of a healthy feeder

  11. DOE assessment guide for safeguards and security

    International Nuclear Information System (INIS)

    Bennett, C.A.; Christorpherson, W.E.; Clark, R.J.; Martin, F.; Hodges, Jr.

    1978-04-01

    DOE operations are periodically assessed to assure that special nuclear material, restricted data, and other classified information and DOE facilities are executed toward continuing the effectiveness of the International Atomic Energy Agency safeguards. A guide to describe the philosophy and mechanisms through which these assessments are conducted is presented. The assessment program is concerned with all contractor, field office, and Headquarters activities which are designed to assure that safeguards and security objectives are reached by contractors at DOE facilities and operations. The guide takes into account the interlocking relationship between many of the elements of an effective safeguards and security program. Personnel clearance programs are a part of protecting classified information as well as nuclear materials. Barriers that prevent or limit access may contribute to preventing theft of government property as well as protecting against sabotage. Procedures for control and surveillance need to be integrated with both information systems and procedures for mass balance accounting. Wherever possible, assessment procedures have been designed to perform integrated inspection, evaluation, and follow-up for the safeguards and security program

  12. Dynamic modelling and experimental study of cantilever beam with clearance

    International Nuclear Information System (INIS)

    Li, B; Jin, W; Han, L; He, Z

    2012-01-01

    Clearances occur in almost all mechanical systems, typically such as the clearance between slide plate of gun barrel and guide. Therefore, to study the clearances of mechanisms can be very important to increase the working performance and lifetime of mechanisms. In this paper, rigid dynamic modelling of cantilever with clearance was done according to the subject investigated. In the rigid dynamic modelling, clearance is equivalent to the spring-dashpot model, the impact of beam and boundary face was also taken into consideration. In ADAMS software, the dynamic simulation was carried out according to the model above. The software simulated the movement of cantilever with clearance under external excitation. Research found: When the clearance is larger, the force of impact will become larger. In order to study how the stiffness of the cantilever's supporting part influences natural frequency of the system, A Euler beam which is restricted by a draught spring and a torsion spring at its end was raised. Through numerical calculation, the relationship between natural frequency and stiffness was found. When the value of the stiffness is close to the limit value, the corresponding boundary condition is illustrated. An ADAMS experiment was carried out to check the theory and the simulation.

  13. Dynamic modelling and experimental study of cantilever beam with clearance

    Science.gov (United States)

    Li, B.; Jin, W.; Han, L.; He, Z.

    2012-05-01

    Clearances occur in almost all mechanical systems, typically such as the clearance between slide plate of gun barrel and guide. Therefore, to study the clearances of mechanisms can be very important to increase the working performance and lifetime of mechanisms. In this paper, rigid dynamic modelling of cantilever with clearance was done according to the subject investigated. In the rigid dynamic modelling, clearance is equivalent to the spring-dashpot model, the impact of beam and boundary face was also taken into consideration. In ADAMS software, the dynamic simulation was carried out according to the model above. The software simulated the movement of cantilever with clearance under external excitation. Research found: When the clearance is larger, the force of impact will become larger. In order to study how the stiffness of the cantilever's supporting part influences natural frequency of the system, A Euler beam which is restricted by a draught spring and a torsion spring at its end was raised. Through numerical calculation, the relationship between natural frequency and stiffness was found. When the value of the stiffness is close to the limit value, the corresponding boundary condition is illustrated. An ADAMS experiment was carried out to check the theory and the simulation.

  14. Airway Clearance Techniques (ACTs)

    Medline Plus

    Full Text Available ... many challenges, including medical, social, and financial. By learning more about how you can manage your disease every day, you can ultimately help find a ... Cycle of Breathing Technique Airway Clearance Techniques Autogenic ...

  15. Refrigeration system with clearance seals

    International Nuclear Information System (INIS)

    Holland, N. J.

    1985-01-01

    In a refrigeration system such as a split Stirling system, fluid seals associated with the reciprocating displacer are virtually dragless clearance seals. Movement of the displacer relative to the pressure variations in the working volume of gas is retarded by a discrete braking element. Because it is not necessary that the brake providing any sealing action, the brake can be designed for greater durability and less dependence on ambient and operating temperatures. Similarly, the clearance seal can be formed of elements having low thermal expansion such that the seal is not temperature dependent. In the primary embodiments the braking element is a split friction brake

  16. Chaos vibration of pinion and rack steering trapezoidal mechanism containing two clearances

    Science.gov (United States)

    Wei, Daogao; Wang, Yu; Jiang, Tong; Zheng, Sifa; Zhao, Wenjing; Pan, Zhijie

    2017-08-01

    The multi-clearances of breaking type steering trapezoidal mechanism joints influences vehicle steering stability. Hence, to ascertain the influence of clearance value on steering stability, this paper takes the steering mechanism of a certain vehicle type as a prototype that can be simplified into a planar six-bar linkage, then establishes the system dynamic differential equations after considering the two clearances of tie rods and the steering knuckle arms. The influence of the clearance parameters on the movement stability of the steering mechanism is studied using a numerical computation method. Results show that when the two clearances are equal, the planar movement of the tie rods changes from period-doubling to chaos as the clearances increase. When the two clearances are 0.25 mm and 1.5 mm respectively, the planar movements of the two side tie rods come into chaos, causing the steering stability to deteriorate. Moreover, with the increase of clearances, turning moment fluctuates more intensively and the peak value increases.

  17. Airway Clearance Techniques (ACTs)

    Medline Plus

    Full Text Available ... decisions about your health care. CF Genetics: The Basics CF Mutations Video Series Find Out More About ... of Breathing Technique Airway Clearance Techniques Autogenic Drainage Basics of Lung Care Chest Physical Therapy Coughing and ...

  18. Airway Clearance Techniques (ACTs)

    Medline Plus

    Full Text Available ... Clinician Career Development Awards Clinician Training Awards Mutation Analysis Program Network News Network News: March 2018 Network ... for airway clearance. Facebook Twitter Email More Related Content Medications Autogenic Drainage Positive Expiratory Pressure High-Frequency ...

  19. Airway Clearance Techniques (ACTs)

    Medline Plus

    Full Text Available ... today. ANNUAL FUND Become a Corporate Supporter Cause Marketing Make a Charitable Gift Our Corporate Supporters Workplace ... for airway clearance. Facebook Twitter Email More Related Content Medications Autogenic Drainage Positive Expiratory Pressure High-Frequency ...

  20. Airway Clearance Techniques (ACTs)

    Medline Plus

    Full Text Available ... specialized CF care and a range of treatment options. Airway Clearance Active Cycle of Breathing Technique Airway ... on their own. Share Facebook Twitter Email More options Print Share Facebook Twitter Email Print Permalink All ...

  1. Airway Clearance Techniques (ACTs)

    Medline Plus

    Full Text Available ... Clinician Career Development Awards Clinician Training Awards Mutation Analysis Program Network News Network News: June 2018 Network ... for airway clearance. Facebook Twitter Email More Related Content Medications Autogenic Drainage Positive Expiratory Pressure High-Frequency ...

  2. Airway Clearance Techniques (ACTs)

    Medline Plus

    Full Text Available ... a Family Parenting as an Adult With CF Treatments and Therapies People with cystic fibrosis are living ... to specialized CF care and a range of treatment options. Airway Clearance Active Cycle of Breathing Technique ...

  3. Airway Clearance Techniques (ACTs)

    Medline Plus

    Full Text Available ... Physical Therapy Coughing and Huffing High-Frequency Chest Wall Oscillation Positive Expiratory Pressure Clinical Trials Clinical Trials ... clapping) or vibration to loosen mucus from airway walls. See how different airway clearance techniques work to ...

  4. Airway Clearance Techniques (ACTs)

    Medline Plus

    Full Text Available ... in part to specialized CF care and a range of treatment options. Airway Clearance Active Cycle of ... a cure for CF and supports a broad range of research initiatives to tackle the disease from ...

  5. Airway Clearance Techniques (ACTs)

    Medline Plus

    Full Text Available ... ACTs involve coughing or huffing . Many of them use percussion (clapping) or vibration to loosen mucus from airway walls. See how different airway clearance techniques work to help you clear the thick, sticky mucus ...

  6. Airway Clearance Techniques (ACTs)

    Medline Plus

    Full Text Available ... Clinical Care Guidelines Liver Disease Clinical Care Guidelines Respiratory Care Guidelines CF Airway Clearance Therapies Clinical Care ... attack bacteria. Choose What's Best for You Your respiratory therapist or another member of your CF care ...

  7. Airway Clearance Techniques (ACTs)

    Medline Plus

    Full Text Available ... Cycle of Breathing Technique Airway Clearance Techniques Autogenic Drainage Basics of Lung Care Chest Physical Therapy Coughing ... Facebook Twitter Email More Related Content Medications Autogenic Drainage Positive Expiratory Pressure High-Frequency Chest Wall Oscillation ( ...

  8. Measurement with nasal scintigraphy of nasal mucociliary clearance in normal man

    International Nuclear Information System (INIS)

    Murai, Sumiko

    1989-01-01

    Nasal mucociliary function was evaluated by nasal scintigraphy in normal subjects. A microdrop of HSA or saline labelled with 99m Tc was dripped into the middle part of each middle meatus in the nasal cavity and its clearance was observed by scinticamera. The accumulated concentration of RI was determined every 30 seconds for 10 minutes. The changes of accumulated concentration were studied, and a curve of decreasing RI-counts was obtained, with the 'clearance rate' defined as 100% for the count at the initial 30 seconds and 'half time' as the time when radioactivity was reduced to one half the initial count. Nasal resistance was measured by rhinomanometry with the oscillation method. In nonsmokers, 10μl of saline was cleared (78.0±10.4%) significantly faster than 10μl of HSA (59.9±24.6%), and there was no significant difference in the clearance between 10μl and 5μl of HSA (55.9±27.7%). In smakers, the mucociliary clearance of 10μl of HSA and saline was significantly lower than in nonsmokers. The clearance of 10μl of HSA reflects a pathological state much better than that of 5μl. In nonsmokers, there is a significant negative correlation between nasal resistance and clearance rate, suggesting that the more patent the nose, the faster the mucociliary clearance. When both nostrils were closed, the clearance rate was significantly depressed. When one nostril was closed, there was no significant effect on clearance. Nasal resistance was decreased by exercise with a bicycle ergometer. Nasal mucociliary clearance was slightly decreased after exercise but not significantly so. (J.P.N.)

  9. 78 FR 77027 - Overhead Clearance (Air-Draft) Accidents

    Science.gov (United States)

    2013-12-20

    ... No. USCG-2013-0466] Overhead Clearance (Air-Draft) Accidents AGENCY: Coast Guard, DHS. ACTION... clearance (air-draft) accidents. In its petition, which calls for vessel masters to be provided with... accidents that it says were avoidable and that resulted in damage to or destruction of waterway...

  10. The role of clearance in Germany - release of materials, buildings and sites

    International Nuclear Information System (INIS)

    Thierfeldt, S.

    2005-01-01

    Clearance in Germany is far advanced. A complex regulatory framework exists in the Radiation Protection Ordinance (RPO/Strahlenschutzverordnung, StrlSchV) since 2001 which has replaced previous recommendations on clearance issued by the German Radiation Protection Commission (Strahlenschutzkommission, SSK). A number of options exist both for unconditional clearance (e.g. of all kinds of materials with no restrictions on the destination or future use) and for clearance for a specific purpose (e.g. recycling of metal scrap). For each clearance option there is a set of nuclide specific clearance levels which have been derived on the basis of the 10 Sv/a individual dose criterion using complex radiological models which are tailored to the respective material cycles (metal scrap, buildings, building rubble, waste for disposal, sites). The clearance levels have been thoroughly reviewed by the SSK. An extensive comparison to sets of clearance levels used in other countries or issued as guidance by international bodies revealed that the correspondence between values is between good and acceptable taking into account country-specific approaches and special assumptions which would not necessarily pertain to German situations. Clearance is a major factor in the material management, especially of nuclear installations undergoing decommissioning. The variety of clearance options leaves the operator of a nuclear installation sufficient flexibility for optimisation of the material management. Clearance is of particular importance in a country like Germany where the estimated costs for a future repository are very high and the interim storage facilities for radioactive material are limited and costly. While the licensee is responsible for his material management, the issuance of a clearance permit is done by the regulatory body upon application. The regulators may choose to use the clearance levels and regulations as stipulated by the RPO, or to impose site-specific regulations on

  11. Whole body and regional clearances of noradrenaline and adrenaline in man

    DEFF Research Database (Denmark)

    Christensen, N J; Galbo, H; Gjerris, A

    1984-01-01

    the clearance values based on arterial and venous sampling averaged 1.4 and 2.5 l/min, respectively (p less than 0.02). The difference in clearance values was due to peripheral uptake of NA averaging 45%. The plasma appearance rate on NA averaged 2.4 nmol/min before surgery and it increased to 9.5 nmol...... we found no correlation between clearance values based on venous and arterial sampling. In other experiments we measured the influence of physical exercise in young healthy subjects on the clearance rate of plasma adrenaline (A). The clearance of A, which at rest averaged 1.9 l/min tended to increase...

  12. Airway Clearance Techniques (ACTs)

    Medline Plus

    Full Text Available ... Make a Charitable Gift Our Corporate Supporters Workplace Engagement DONATE YOUR PROPERTY eCards for a Cure About ... airway walls. See how different airway clearance techniques work to help you clear the thick, sticky mucus ...

  13. Airway Clearance Techniques (ACTs)

    Medline Plus

    Full Text Available ... people with cystic fibrosis so that they make smart decisions about CF-related research, treatment, and access ... Facebook Twitter YouTube Instagram Email DONATE Breadcrumb Navigation Home Life With CF Treatments and Therapies Airway Clearance ...

  14. Airway Clearance Techniques (ACTs)

    Medline Plus

    Full Text Available ... 3-D Structure Consortium CFTR Folding Consortium Epithelial Stem Cell Consortium Mucociliary Clearance Consortium SUCCESS WITH THERAPIES RESEARCH ... ACTs involve coughing or huffing . Many of them use percussion (clapping) or vibration to loosen mucus from ...

  15. Airway Clearance Techniques (ACTs)

    Medline Plus

    Full Text Available ... CFTR Modulator Therapies Mucus Thinners Nebulizer Care at Home Vascular Access Devices PICCs and Ports Partnerships for ... Facebook Twitter YouTube Instagram Email DONATE Breadcrumb Navigation Home Life With CF Treatments and Therapies Airway Clearance ...

  16. Online monitoring of dynamic tip clearance of turbine blades in high temperature environments

    Science.gov (United States)

    Han, Yu; Zhong, Chong; Zhu, Xiaoliang; Zhe, Jiang

    2018-04-01

    Minimized tip clearance reduces the gas leakage over turbine blade tips and improves the thrust and efficiency of turbomachinery. An accurate tip clearance sensor, measuring the dynamic clearances between blade tips and the turbine case, is a critical component for tip clearance control. This paper presents a robust inductive tip clearance sensor capable of monitoring dynamic tip clearances of turbine machines in high-temperature environments and at high rotational speeds. The sensor can also self-sense the temperature at a blade tip in situ such that temperature effect on tip clearance measurement can be estimated and compensated. To evaluate the sensor’s performance, the sensor was tested for measuring the tip clearances of turbine blades under various working temperatures ranging from 700 K to 1300 K and at turbine rotational speeds ranging from 3000 to 10 000 rpm. The blade tip clearance was varied from 50 to 2000 µm. The experiment results proved that the sensor can accurately measure the blade tip clearances with a temporal resolution of 10 µm. The capability of accurately measuring the tip clearances at high temperatures (~1300 K) and high turbine rotation speeds (~30 000 rpm), along with its compact size, makes it promising for online monitoring and active control of blade tip clearances of high-temperature turbomachinery.

  17. Creatinine clearance during cimetidine administration for measurement of glomerular filtration rate

    NARCIS (Netherlands)

    van Acker, B. A.; Koomen, G. C.; Koopman, M. G.; de Waart, D. R.; Arisz, L.

    1992-01-01

    Creatinine clearance inaccurately estimates true glomerular filtration rate (GFR) because of tubular secretion of creatinine. We studied the ability of oral cimetidine, a blocker of tubular creatinine secretion, to improve the accuracy of measuring creatinine clearance. Clearances of inulin and

  18. Depressed reticuloendothelial clearance of platelets in rats after trauma.

    Science.gov (United States)

    Kaplan, J E; Moon, D G; Minnear, F L; Saba, T M

    1984-02-01

    Platelet microembolization may contribute to microcirculatory and organ damage following trauma and shock. It is hypothesized that posttraumatic reticuloendothelial depression predisposes to such microembolization by failure to clear altered platelets from the circulation. The present study evaluated the short-term (1 h) clearance and organ localization of radiolabeled homologous damaged platelets in normal rats and in rats following sublethal Noble-Collip drum trauma. Platelets were collected in citrated platelet-rich plasma from normal rats and labeled with 51Cr in citrated saline. Platelets were altered by repeated centrifugation in protein-free medium. These platelets differed functionally and morphologically from normal platelets. Disappearance of iv injected damaged platelets conformed to a two-compartment exponential clearance. Velocity of clearance in the rapid compartment correlated with hepatic platelet localization, whereas velocity of clearance in the second compartment correlated with splenic platelet localization. Clearance rate of the rapid compartment was depressed at 1 h after trauma and elevated at 24 h. These changes were associated with a decrease in hepatic platelet localization at 1 h and an increase above normal at 24 h. Splenic platelet localization was decreased by 3 h following trauma. Pulmonary platelet localization was increased at all times following trauma. It is concluded that the posttrauma state is associated with a defect in the reticuloendothelial system clearance of altered platelets, which may augment embolization of platelets in the lung.

  19. Intercalibration of mussel Mytilus edulis clearance rate measurements

    NARCIS (Netherlands)

    Kjerulf Petersen, J.; Bougrier, S.; Smaal, A.C.; Garen, P.; Robert, S.; Larsen, J.E.N.; Brummelhuis, E.B.M.

    2004-01-01

    Clearance rate (CR) was measured in blue mussels Mytilus edulis L. from Aiguillon Bay and the Oosterschelde using 3 different methods: the flow-through method, the bio-deposition method and the indirect or clearance method. CR differed significantly as a function of the method used and of the origin

  20. Airway Clearance Techniques (ACTs)

    Medline Plus

    Full Text Available ... a Family Parenting as an Adult With CF Treatments and Therapies People with cystic fibrosis are living longer and ... to specialized CF care and a range of treatment options. Airway Clearance Active Cycle of Breathing Technique ...

  1. Assessment of renal function with the Tc-99m-MAG3 clearance

    International Nuclear Information System (INIS)

    Keske, U.; Corcles, M.; Andreessen, R.; Wilfling, M.; Roll, D.; Gahl, G.; Felix, R.

    1990-01-01

    This paper evaluates the applicability of the 99m-Tc-mercaptoacetyle-triglycine (MAG3) clearance for the documentation of renal function. Renal clearance was measured with the method of Tauxe in 699 patients during routine renal scintigraphy with 80 MBq of 99mTc-MAG3. Serum creatinine level and MAG3 clearance show an inverse correlation. Patients with an elevated serum creatinine level constantly have a lowered MAG3 clearance and vice versa. For creatinine values lower than 1.8 mg/dL, minor changes in creatinine level are accompanied by large changes in MAG3 clearance. Age (in years) dependence of MAG3 clearance was evaluated in 487 patients who showed no evidence of impaired renal function

  2. Effects of heart rate on myocardial thallium-201 uptake and clearance

    International Nuclear Information System (INIS)

    Nordrehaug, J.E.; Danielsen, R.; Vik-Mo, H.

    1989-01-01

    The effects of heart rate on the myocardial uptake and clearance of 201 Tl were studied prospectively in seven healthy men, mean age 43 +/- 7 (s.d.) yr. Initial and delayed (3 hr) thallium images were obtained in three views after three bicycle exercise tests: to maximal, 80% and 60% of predicted maximal heart rate. The mean of three views initial myocardial 201 Tl uptake was higher at maximal than at both 80% and 60% of predicted maximal heart rate, being 81% (p less than 0.01) and 60% (p less than 0.01) of maximal activity, respectively. The myocardial activity in the delayed images was identical. There was a linear relationship between heart rate and the initial myocardial activity, r = 0.86 (p less than 0.001). The mean (range) 201 Tl clearance was 58% (51-65), 47% (34-56), and 34% (22-49) (all differences p less than 0.01), respectively. Concordance among the three individual views in estimating clearance was best for the highest exercise level. There was a linear relationship between heart rate and clearance, r = 0.80 (p less than 0.001). Clearance was altered by only 1.67 x 10%/heart bpm (0.024 hr/heart beat). Clearance in the liver, spleen and lungs increased at submaximal exercise levels. Thus, a linear relationship between heart rate and clearance is the result of changes in the initial exercise myocardial 201 Tl activity. Submaximal exercise may reduce reproducibility of clearance estimation, and the change of myocardial clearance with heart rate seems less than previously suggested

  3. Factors affecting lower calyceal stone clearance after Extracorporeal ...

    African Journals Online (AJOL)

    shanker

    have been identified [1,3]. These include stone characteristics, the type of lithotripter used, LPC anatomy and body habitus. For iso- lated LPC stones, the pelvicalyceal angle, infundibulum length and width are considered important determinants for stone clearance. The impact of body habitus on stone clearance has so far ...

  4. 78 FR 62430 - Department of Defense (DoD)-Defense Industrial Base (DIB) Voluntary Cyber Security and...

    Science.gov (United States)

    2013-10-22

    ... requisite points of contact information, to include security clearance and citizenship information, for the... participants to DC3 under paragraphs (b), (c) and (d) of this section are maintained by the digital and... accreditation as a digital and multimedia forensics laboratory. DC3 will maintain, control, and dispose of all...

  5. Delayed clearance of triglyceride‐rich lipoproteins in young, healthy obese subjects†

    Science.gov (United States)

    Goll, R.; Lekahl, S.; Moen, O. S.; Florholmen, J.

    2015-01-01

    Summary Obesity is associated with the metabolic syndrome. The aims were, first, to study the postprandial triglyceride clearance in young, healthy obese subjects and, second, to investigate if fasting triglycerides can predict delayed postprandial triglyceride clearance. Eighteen apparently healthy, obese subjects with no clinical signs of metabolic disturbances participated. Controls were age‐ and sex‐matched, healthy, normal weight subjects. Subclinical markers of metabolic disturbances were assessed by measuring postprandial triglycerides in serum and in chylomicrons by oral fat tolerance test. Postprandial triglyceride clearance for 8 h was assessed indirectly as removal of the lipid from serum during the oral fat tolerance test. Insulin resistance was measured by the homeostasis model assessment of insulin resistance (HOMA‐IR). Twelve (66%) of the apparently healthy obese individuals had insulin resistance measured by HOMA‐IR. There was a delayed clearance of serum triglycerides and chylomicron triglycerides at 6 h when compared with the control group, while, at 8 h, the differences were only detected for the chylomicron triglyceride clearance. Triglyceride response was significantly greater in the obese subjects. Fasting triglycerides in upper normal level predicted a delayed postprandial triglyceride clearance and insulin resistance. In young, apparently healthy obese subjects early metabolic disturbances including insulin resistance and delayed postprandial triglyceride clearance can be detected. Fasting serum triglyceride in upper normal level predicted delayed postprandial triglyceride clearance and insulin resistance. PMID:26469529

  6. Delayed clearance of triglyceride-rich lipoproteins in young, healthy obese subjects.

    Science.gov (United States)

    Larsen, M A; Goll, R; Lekahl, S; Moen, O S; Florholmen, J

    2015-12-01

    Obesity is associated with the metabolic syndrome. The aims were, first, to study the postprandial triglyceride clearance in young, healthy obese subjects and, second, to investigate if fasting triglycerides can predict delayed postprandial triglyceride clearance. Eighteen apparently healthy, obese subjects with no clinical signs of metabolic disturbances participated. Controls were age- and sex-matched, healthy, normal weight subjects. Subclinical markers of metabolic disturbances were assessed by measuring postprandial triglycerides in serum and in chylomicrons by oral fat tolerance test. Postprandial triglyceride clearance for 8 h was assessed indirectly as removal of the lipid from serum during the oral fat tolerance test. Insulin resistance was measured by the homeostasis model assessment of insulin resistance (HOMA-IR). Twelve (66%) of the apparently healthy obese individuals had insulin resistance measured by HOMA-IR. There was a delayed clearance of serum triglycerides and chylomicron triglycerides at 6 h when compared with the control group, while, at 8 h, the differences were only detected for the chylomicron triglyceride clearance. Triglyceride response was significantly greater in the obese subjects. Fasting triglycerides in upper normal level predicted a delayed postprandial triglyceride clearance and insulin resistance. In young, apparently healthy obese subjects early metabolic disturbances including insulin resistance and delayed postprandial triglyceride clearance can be detected. Fasting serum triglyceride in upper normal level predicted delayed postprandial triglyceride clearance and insulin resistance. © 2015 World Obesity.

  7. Dynamic characteristics analysis of deployable space structures considering joint clearance

    Science.gov (United States)

    Li, Tuanjie; Guo, Jian; Cao, Yuyan

    2011-04-01

    The clearance in joints influences the dynamic stability and the performance of deployable space structures (DSS). A virtual experimental modal analysis (VEMA) method is proposed to deal with the effects of joint clearance and link flexibility on the dynamic characteristics of the DSS in this paper. The focus is on the finite element modeling of the clearance joint, VEMA and the modal parameters identification of the DSS. The finite element models (FEM) of the clearance joint and the deployable structure are established in ANSYS. The transient dynamic analysis is conducted to provide the time history data of excitation and response for the VEMA. The fast Fourier transform (FFT) technique is used to transform the data from time domain to frequency domain. The frequency response function is calculated to identify the modal parameters of the deployable structure. Experimental verification is provided to indicate the VEMA method is both a cost and time efficient approach to obtain the dynamic characteristics of the DSS. Finally, we analyze the effects of clearance size and gravity on the dynamic characteristics of the DSS. The analysis results indicate that the joint clearance and gravity strongly influence the dynamic characteristics of the DSS.

  8. 32 CFR 644.522 - Clearance of military scrap.

    Science.gov (United States)

    2010-07-01

    ... 32 National Defense 4 2010-07-01 2010-07-01 true Clearance of military scrap. 644.522 Section 644... Excess Land and Improvements § 644.522 Clearance of military scrap. Military scrap can contain or be... destruction, by using command, of all military scrap and scrap metal from lands suitable for cultivation or...

  9. Applicability of Clearance Automatic Laser Inspection System to Clearance Measurement of Concrete Segments

    International Nuclear Information System (INIS)

    Sasaki, M.; Ogino, H.; Hattori, T.

    2009-01-01

    In the decommissioning of a nuclear power plant, large amounts of metal scrap and concrete segments require disposal when dismantling the nuclear reactor and surrounding facilities. When their activity level is negligible or sufficiently small, they can be regarded as general industrial waste. To distinguish between radioactive and nonradioactive materials, the clearance level for each radionuclide has been determined in units of activity concentration. These clearance levels are indicated in the International Atomic Energy Agency (IAEA) Safety Standards Series No. RS-G-1.7. The Japanese regulatory authority decided in 2005 to adopt the values given in RS-G-1.7 as clearance levels in legislation. Recently, a Clearance Automatic Laser Inspection System (CLALIS) has been developed utilizing gamma-ray measurement, automatic laser shape measurement and Monte Carlo calculation. CLALIS comprises four laser scanners and eight large plastic scintillation detectors surrounded by a 5-cm-thick lead shield. Using three-dimensional (3D) laser scanning, a measurement target, which is placed on the measuring tray, is represented as a dot image. The dot image is converted into voxels after noise removal, and is written in MCNP (A General Monte Carlo N-Particle Transport Code System) input files. When the gamma-ray measurement is carried out, the MCNP calculations are also carried out to obtain the calibration factor and background (BG) correction factors. For the clearance measurement of concrete segments, the effect of gamma-rays from natural radionuclides in the measurement target, such as K-40 and the radioactive decay products of Th-232 and U-238, should be taken into account to ensure adequate waste management. Since NE102A plastic scintillation detectors are used for gamma-ray measurement in CLALIS, it is impossible to distinguish between the count rates of natural radionuclides and contaminants on the basis of gamma-ray energy information. To overcome this problem, the

  10. Airway Clearance Techniques (ACTs)

    Medline Plus

    Full Text Available ... Offer their tips for fitting ACTs into daily life Airway Clearance Techniques | Webcast To learn more about how you can help your infant or child manage their lung health, watch parents of children with CF and a respiratory therapist ...

  11. Clearance level and industrial waste management

    International Nuclear Information System (INIS)

    Asano, Toichi

    1999-01-01

    Defining the clearance level enables the radioactive waste with lower radioactivity than a certain level to be the general industrial waste and therefore consideration for public acceptance is essential. For this, it is necessary to understand laws concerning not only atomic power and radioactivity but also disposal and cleaning of general waste. It is also necessary that the waste below the clearance level should be as much as possible handled in the modern common concept of recycling of resources. In 1996, the weight of industrial waste was about 400 million tons, of which 40% was disposed by burning and dehydration, 39% was re-used and 21% was subjected to the final disposal like reclamation. Reduction, re-use and recycling of the generated waste are required for making the society with recycling of resources. Scrap concrete materials below the clearance level of 0.6 million tons are estimated to be generated by dismantling the light water reactor of 1 million kW output and profitable technology for recycling the scrap is under investigation. (K.H.)

  12. Factors Associated with Spontaneous Clearance of Hepatitis C Virus in Chinese Population

    Directory of Open Access Journals (Sweden)

    Fei Kong

    2014-01-01

    Full Text Available Hepatitis C virus (HCV infections spontaneously clear in approximately 15–45% of infected individuals. Factors which influence spontaneous HCV clearance remain to be identified. The purpose of the present study was to identify variables associated with spontaneous HCV clearance in a referred population of Chinese patients. The prevalence of host, viral, and environmental factors known to influence the outcome of HCV infections was compared in 92 HCV spontaneous clearance subjects and 318 HCV persistent infection subjects. Univariate and multivariate analyses were performed to identify those factors associated with spontaneous HCV clearance. In univariate analysis, female gender, a history of icteric hepatitis, serologic evidence of concurrent HBV infection, and rs12979860 CC genotype were positively associated with spontaneous HCV clearance, while alcohol consumption was negatively associated with clearance. In multivariate analysis, female gender, a history of icteric hepatitis, concurrent HBV infection, and rs12979860 CC genotype remained independent variables associated with spontaneous HCV clearance. Spontaneous HCV clearance is more likely to occur in females, subjects with a history of icteric hepatitis, HBV coinfections, and those with the rs12979860 CC genotype.

  13. Airway Clearance Techniques (ACTs)

    Medline Plus

    Full Text Available ... how you can help your infant or child manage their lung health, watch parents of children with CF and a respiratory therapist talk about the different techniques they use for airway clearance. Facebook Twitter Email More Related Content Medications Autogenic Drainage ...

  14. 49 CFR 236.22 - Semaphore signal arm; clearance to other objects.

    Science.gov (United States)

    2010-10-01

    ... 49 Transportation 4 2010-10-01 2010-10-01 false Semaphore signal arm; clearance to other objects... Rules and Instructions: All Systems Roadway Signals and Cab Signals § 236.22 Semaphore signal arm; clearance to other objects. At least one-half inch clearance shall be provided between semaphore signal arm...

  15. Whole body and regional clearances of noradrenaline and adrenaline in man

    DEFF Research Database (Denmark)

    Christensen, N J; Galbo, H; Gjerris, Anne Cathrine Roslev

    1984-01-01

    we found no correlation between clearance values based on venous and arterial sampling. In other experiments we measured the influence of physical exercise in young healthy subjects on the clearance rate of plasma adrenaline (A). The clearance of A, which at rest averaged 1.9 l/min tended to increase...

  16. Using Terrestrial Laser Scanners to Calculate and Map Vertical Bridge Clearance

    Science.gov (United States)

    Zhang, C.; Arditi, D.; Chen, Z.

    2013-08-01

    The vertical clearance of a bridge over a highway is important in preventing oversized vehicles from hitting the bridge. The vertical clearance of a bridge is traditionally measured by using surveying equipment such as leveling rods and total stations. Typically, measurements are taken at multiple locations in order to determine the minimum vertical clearance under the bridge. This process is time and labor consuming. Also, these measurements may not be accurate because of the traffic, the uneven surface, and the reading error caused by the surveyor. Additionally, when one is faced with a multitude of reports especially in large projects with multiple ramps and bridges, it is not easy and it often takes a long time to find the bridge under study. This research provides a highly accurate measurement of the vertical bridge clearance by using terrestrial laser scanners. The clearance can be measured in the office by processing the collected point cloud data. The minimum vertical clearance is easily identified and the measurement is visualized and geo-referenced. An approach to reduce data noise caused by traffic is also introduced in this study. In addition, to help reduce the confusion of finding the bridge under study and to facilitate access to the clearance data, the clearance measurements are geo-referenced to an online mapping system. This system allows access to the final deliverable very easily through a single web portal. Finally, Illinois Department of Transportation's Circle Interchange is used to demonstrate this new method.

  17. Securing radioactive sources into disuse, NORM, management, security assessment, exclusion, exemption and clearance

    International Nuclear Information System (INIS)

    Bastidas Pazmino, Jorge

    2008-01-01

    Full text: The Ecuadorian Atomic Energy Commission, through the unity of Radiation Protection Services, with the area of Radioactive Waste Management, has made the study of disused radioactive sources at the national level and are kept in the Temporary Storage of Radioactive Waste; has been made joint efforts with the Department of Energy of the United States for the repatriation of sources originating in that country; similarly, the use of radioactive materials in medicine, industry and research has had a significant increase in the country in the recent years, resulting in the generation of radioactive wastes requiring proper management, to ensure protection to human health and the environment now and into the future. Ecuador, through the Ecuadorian Atomic Energy Commission ensures that the Radioactive Waste Management is done by ensuring an adequate level of protection to human beings and the environment, seeks to meet the objectives of protection of human health, environmental protection, protection beyond national borders; protection of future generations; charges imposed on future generations; national legal framework; control of the production of radioactive wastes; unit interplay between production and radioactive waste management; security installations; in the same way within this framework are the NORM of which has been carried out preliminary studies in the Ecuador Orient, which is part of the lung that Amazon uses oxygen to the whole world, have been submitted NORM as a result of oil hidden within the operation, which has presented measures of exposure high inlays within hose from the wells operating and currently looking to move to the next stage, which are considering different alternatives for managing radioactive waste as more appropriate. (author)

  18. Respiratory clearance of aerosolized radioactive solutes of varying molecular weight

    International Nuclear Information System (INIS)

    Huchon, G.J.; Montgomery, A.B.; Lipavsky, A.; Hoeffel, J.M.; Murray, J.F.

    1987-01-01

    To determine the influence of varying molecular weight (mol wt) on respiratory clearance of aerosolized solutes, we studied eight radiopharmaceuticals, each administered to four dogs: sodium /sup 99m/Tc pertechnetate (TcO4), /sup 99m/Tc glucoheptonate ([/sup 99m/Tc]GH), 51Cr-ethylenedinitrotetraacetate ([51Cr]EDTA), /sup 99m/Tc diethylenetriaminepentaacetate ([99mTc] DTPA), 111 In diethylenetriaminepentaacetate ([ 111 In]DTPA), 67 Ga desferoxaminemesylate ([ 67 Ga]DFOM), /sup 99m/Tc dextran ([/sup 99m/Tc]DX) and 111 In transferrin ([ 111 In]TF). After aerosolization (0.8 m MMD, 2.4 GSD), clearance was determined for 30 min and then corrected by intravenous injection for nonairspace radioactivity. In-TF clearance (0.11 +/- 0.10%/min) was lower than TcO4 (6.32 +/- 0.62%/min), [/sup 99m/Tc]GH (1.50 +/- 0.37%/min), [ 51 Cr]EDTA (2.38 +/- 1.02%/min), [/sup 99m/Tc]DTPA (3.51 +/- 0.40%/min), [ 111 In]DTPA (2.35 +/- 0.42%/min), [ 67 Ga] DFOM (1.99 +/- 0.49%/min) and [/sup 99m/Tc]DX (1.81 +/- 0.75%/min) clearances (p less than 0.001). TcO4 clearance was higher than others (p less than 0.001). Technetium binding to DX was unsatisfactory; aerosolization caused unbinding from DTPA. We conclude that respiratory clearance of large mol wt solutes within 30 min is negligible and, that clearance of molecules between 347-5099 daltons differs greatly, suggesting that binding and/or intrapulmonary retention affect transfer

  19. Comparison of German and international clearance regulations - chances and limits for harmonization

    International Nuclear Information System (INIS)

    Thierfeldt, S.; Schartmann, F.

    2005-01-01

    The regulations on clearance in the German nuclear regulatory framework (especially sect. 29 and Annexes III and IV of the Radiation Protection Ordinance) are comprehensive and well founded. Germany has developed some of its clearance levels in advance of recommendations issued by the EC. Therefore, there are differences between the German and international clearance regulations. That has been investigated by a working group on clearance of the German Commission on Radiological Protection (SSK) which has performed an analysis of differences and their reasons for clearance levels in Germany and other countries (UK, The Netherlands, Sweden, USA and others). Differences can mainly be explained by country specific approaches in scenarios. Differences especially for the most relevant nuclides are not significant from a radiological point of view. The level of radiological protection (trivial dose range, a few 10 μSv/a) is guaranteed in all countries. The international discussion on the international harmonisation of clearance levels (mainly within the scope of the OECD/NEA and IAEA) can be enlightened on the basis of these results. This discussion concentrates on the question how far a harmonisation of clearance level values is actually necessary and possible. The IAEA Safety Guide RS-G-1.7 'Application of the concepts of exclusion, exemption and clearance' is of particular importance, because it proposes a set of values which might in the long-term take the role of international unconditional clearance levels. International harmonisation is only relevant for unconditional clearance of those materials, which are traded in large quantities among countries, in particular metal scrap. Harmonisation of the values to the same order of magnitude is sufficient. (orig.)

  20. Discrepancy between circadian rhythms of inulin and creatinine clearance

    NARCIS (Netherlands)

    van Acker, B. A.; Koomen, G. C.; Koopman, M. G.; Krediet, R. T.; Arisz, L.

    1992-01-01

    To elucidate the disparity between circadian rhythmicity of inulin and creatinine clearance, we simultaneously measured inulin and creatinine clearances every 3 hours during 1 day in 14 normal subjects and in 8 patients with nephrotic syndrome. All patients and normal subjects had a circadian rhythm

  1. Lung clearance of 99m Tc- DTPA in systemic lupus erythematous

    International Nuclear Information System (INIS)

    Dalcin, P.T.R; Barreto, S.S.M.; Xavier, R.M.; Brenol, J.C.T.; Cunha, R.D.; Marroni, B.J.

    2002-01-01

    The early demonstration of lung involvement in systemic lupus erythematosus (SLE) patients is a difficult but important task. In the present study we attempted to identify abnormalities in pulmonary clearance of 99 mTc-DTPA in SLE, correlating their clearance data with clinical findings and disease activity. Forty-six consecutive SLE patients with and without active disease (LACC score) and 30 normal volunteers were studied. All subjects were submitted to pulmonary scintigraphy with 99 mTc-DTPA to evaluate the pulmonary clearance, and to a chest X-ray, and SLE patients were submitted to tests of disease activity, spirometry, arterial blood gases and tests to assess acute-phase proteins. Pulmonary clearance was faster in SLE patients with active disease when compared to normal controls [half-life of 67.04 min (51.52-82.55 min) in active SLE versus 85.87 min (78.85-92.87 min) in controls, P<0.05] and there was a higher frequency of abnormal clearance rates in patients with active disease (11 of 26 patients, 42.3%) when compared with SLE patients without disease activity (2 of 20 patients, 10%) (P = 0.04). A significant correlation was observed between the clearance rates and cough (P<0.05), but not between the clearance rates and dyspnoea symptoms or radiological findings, duration of SLE disease, antinuclear antibody titers and patterns, C-reactive protein or anti-double stranded DNA antibodies. We conclude that the pulmonary clearance of 99 m Tc-DTPA is increased in SLE patients with active disease. (author)

  2. Airway Clearance Techniques (ACTs)

    Medline Plus

    Full Text Available ... cystic fibrosis. CF CARE CENTER finder We provide funding for and accredit more than 120 care centers ... Community in Health Care Reform Milestones in Health Care Reform How Tax Reform Could Impact People With CF The ... Home Life With CF Treatments and Therapies Airway Clearance ...

  3. 48 CFR 32.502-2 - Contract finance office clearance.

    Science.gov (United States)

    2010-10-01

    ... 48 Federal Acquisition Regulations System 1 2010-10-01 2010-10-01 false Contract finance office clearance. 32.502-2 Section 32.502-2 Federal Acquisition Regulations System FEDERAL ACQUISITION REGULATION... finance office clearance. The contracting officer shall obtain the approval of the contract finance office...

  4. 48 CFR 832.502-2 - Contract finance office clearance.

    Science.gov (United States)

    2010-10-01

    ... 48 Federal Acquisition Regulations System 5 2010-10-01 2010-10-01 false Contract finance office clearance. 832.502-2 Section 832.502-2 Federal Acquisition Regulations System DEPARTMENT OF VETERANS AFFAIRS... finance office clearance. Contracting officers must obtain approval from the DSPE before taking the...

  5. Secretion clearance strategies in Australian and New Zealand Intensive Care Units.

    Science.gov (United States)

    Ntoumenopoulos, George; Hammond, Naomi; Watts, Nicola R; Thompson, Kelly; Hanlon, Gabrielle; Paratz, Jennifer D; Thomas, Peter

    2017-06-26

    To describe the processes of care for secretion clearance in adult, intubated and mechanically ventilated patients in Australian and New Zealand Intensive Care Units (ICUs). A prospective, cross-sectional study was conducted through the Australian and New Zealand Intensive Care Society Clinical Trials Group (ANZICS CTG) Point Prevalence Program. Forty-seven ICUs collected data from 230 patients intubated and ventilated on the study day. Secretion clearance techniques beyond standard suctioning were used in 84/230 (37%) of patients during the study period. Chest wall vibration 34/84 (40%), manual lung hyperinflation 24/84 (29%), chest wall percussion 20/84 (24%), postural drainage/patient positioning 17/84 (20%) and other techniques including mobilisation 15/84 (18%), were the most common secretion clearance techniques employed. On average (SD), patients received airway suctioning 8.8 (5.0) times during the 24-h study period. Mucus plugging events were infrequent (2.7%). The additional secretion clearance techniques were provided by physiotherapy staff in 24/47 (51%) ICUs and by both nursing and physiotherapy staff in the remaining 23/47 (49%) ICUs. One-third of intubated and ventilated patients received additional secretion clearance techniques. Mucus plugging events were infrequent with these additional secretion clearance approaches. Prospective studies must examine additional secretion clearance practices, prevalence of mucus plugging episodes and impact on patient outcomes. Crown Copyright © 2017. Published by Elsevier Ltd. All rights reserved.

  6. Influence of peak exercise heart rate on normal thallium-201 myocardial clearance

    International Nuclear Information System (INIS)

    Kaul, S.; Chesler, D.A.; Pohost, G.M.; Strauss, H.W.; Okada, R.D.; Boucher, C.A.

    1986-01-01

    Measurement of myocardial clearance rates between initial and delayed images is a major justification for adding computer quantification to the interpretation of exercise 201 TI images. To clarify the range of normal thallium clearance and its relationship to the level of exercise achieved, exercise thallium images in 89 normal subjects were analyzed: 45 asymptomatic subjects with less than 1% probability of coronary artery disease (CAD) (Group I), and 44 patients with chest pain found to have no significant CAD on angiography (Group II). Mean initial regional thallium uptake was similar in the two groups, but myocardial thallium clearance (mean +/- 1 s.d.) was slower in Group II, expressed as a longer half-life in the myocardium (8.2 +/- 7.6 hr compared with 3.4 +/- 0.7 hr p less than 0.001). Analysis of variance using ten clinical and exercise variables as covariates showed that the slower clearance in Group II was related to a lower peak exercise heart rate (HR) (154 +/- 27 compared with 183 +/- 11, respectively, p less than 0.001). By linear regression analysis, a decrease in peak HR of 1 beat/min was associated with a slower thallium clearance (longer half-life) of 0.05 hr. Using this formula, the clearance value in each patient was then corrected for peak exercise heart rate by decreasing measured clearance by 0.05 hr multiplied by the amount peak exercise heart rate which was below 183 (the mean value in Group I). There were no differences in the corrected clearance between the two groups. We conclude that thallium myocardial clearance after exercise is related in part to factors other than the presence of CAD, being slower when peak exercise HR is lower. Therefore, thallium clearance rates alone uncorrected for peak exercise heart rate should be used with caution when diagnosing CAD

  7. A Study to Determine Clearance Levels of Radioactive Wastes in Kenya

    Energy Technology Data Exchange (ETDEWEB)

    Mukakaa, Zaphania O. [KAIST, Daejeon (Korea, Republic of); Kim, Sung Il [KINS, Daejeon (Korea, Republic of)

    2015-10-15

    Due to lack of a radioactive waste disposal facility in Kenya, radioactive wastes are stored in a bonded warehouse until such a time when their activity is low and they meet the criterion for clearance. The International Atomic Energy Agency (IAEA) has established activity concentrations of radionuclides to act as a universal guideline or standard for clearance in member countries. Radioactive wastes whose activity would yield a trivial risk to the people and environment, i.e. with an annual dose below 10 µSv are usually cleared from regulatory control with no further regulatory control mechanisms being taken. The Radiation Protection Board currently depends on the IAEA's generic clearance level activity concentrations for purposes of clearing the radiation wastes within its inventory. This study aims to determine activity concentrations of radionuclides in the Kenyan inventory that correspond to the clearance level dose of 10 µSv/a as set by the IAEA. The RESidual RADioactivity (RESRAD) computer code, an important tool developed in 1989 to aid in evaluation of sites with radioactive contamination, will aid in modeling these clearance level values using a pathways analysis method and available site-specific data from Kenya. Afterwards, the obtained clearance level values will be compared with the IAEA's generic clearance level values of the corresponding radionuclides. The results modeled using the RESRAD code are conservative. For most of the radionuclides in the Kenyan inventory, the values do correspond with the IAEA standard generic clearance level values, albeit with minor differences. For most of the radionuclides, the difference is within the acceptable uncertainty limit. For these low probability events the effective dose resulting from them should not exceed 1 mSv per year. Thus, consideration was given to doses to the skin and an equivalent dose to the skin of 50 mSv per year was duly used in estimating the clearance level activities. The

  8. Factors contributing to delay in parasite clearance in uncomplicated falciparum malaria in children

    Directory of Open Access Journals (Sweden)

    Sijuade Abayomi

    2010-02-01

    Full Text Available Abstract Background Drug resistance in Plasmodium falciparum is common in many endemic and other settings but there is no clear recommendation on when to change therapy when there is delay in parasite clearance after initiation of therapy in African children. Methods The factors contributing to delay in parasite clearance, defined as a clearance time > 2 d, in falciparum malaria were characterized in 2,752 prospectively studied children treated with anti-malarial drugs between 1996 and 2008. Results 1,237 of 2,752 children (45% had delay in parasite clearance. Overall 211 children (17% with delay in clearance subsequently failed therapy and they constituted 72% of those who had drug failure, i.e., 211 of 291 children. The following were independent risk factors for delay in parasite clearance at enrolment: age less than or equal to 2 years (Adjusted odds ratio [AOR] = 2.13, 95% confidence interval [CI]1.44-3.15, P 50,000/ul (AOR = 2.21, 95% CI = 1.77-2.75, P 20000/μl a day after treatment began, were independent risk factors for delay in clearance. Non-artemisinin monotherapies were associated with delay in clearance and treatment failures, and in those treated with chloroquine or amodiaquine, with pfmdr 1/pfcrt mutants. Delay in clearance significantly increased gametocyte carriage (P Conclusion Delay in parasite clearance is multifactorial, is related to drug resistance and treatment failure in uncomplicated malaria and has implications for malaria control efforts in sub-Saharan Africa.

  9. Effect of glucose-insulin-potassium infusion on thallium myocardial clearance

    International Nuclear Information System (INIS)

    Wilson, R.A.; Okada, R.D.; Strauss, H.W.; Pohost, G.M.

    1983-01-01

    Factors influencing the rate of 201 Tl clearance from the myocardium have not been clearly defined. This study determined the effect of an intravenous infusion of glucose-insulin-potassium (GIK) on the net 201 Tl clearance rates from myocardium with and without initial 201 Tl loading. Anesthetized open-chest dogs underwent 5 min of left anterior descending coronary artery occlusion and intravenous 201 Tl was injected and the occlusion released 5 min later. Thirty minutes after 201 Tl injection, 30 ml of either GIK (nine dogs) or saline (five dogs) was infused intravenously. The clearance rates of 201 Tl from the anterior wall (without initial 201 Tl loading) and from the posterior wall (with initial 201 Tl loading) were monitored with miniaturized cadmium telluride detectors placed on the myocardium. Calculation of net myocardial clearance rates was performed by linear regression analysis from serial 1 min counts. Compared with saline infusion, GIK increased the net clearance of 201 Tl from both myocardial regions with and without initial loading. The most marked change induced by GIK infusion was in the myocardial region without initial 201 Tl loading; a net increase in 201 Tl activity (72 +/- 42 cpm/30 min) was converted into a net loss (-594 +/- 228 cpm/30 min). There was no significant change in 201 Tl clearance after the saline infusion. Heart rate, aortic and left atrial pressure, sonomicrometer-measured transmural myocardial wall thickness, microsphere-determined myocardial blood flow, and blood glucose and potassium concentrations did not change significantly during GIK or saline infusions. Thus, GIK infusion appears to increase net 201 Tl clearance from myocardial zones with and without initial 201 Tl loading

  10. 78 FR 41805 - In the Matter of FirstEnergy Nuclear Operating Company; Beaver Valley Power Station; Independent...

    Science.gov (United States)

    2013-07-11

    .... Government-granted security clearance (i.e., Top Secret, Secret, or Confidential). d. A review of the...'' clearances or possess another active U.S. Government granted security clearance, i.e., Top Secret, Secret or...'' clearances or possess another active U.S. Government granted security clearance, i.e., Top Secret, Secret or...

  11. 76 FR 81542 - In the Matter of ZIONSOLUTIONS, LLC; Zion Nuclear Power Station; Independent Spent Fuel Storage...

    Science.gov (United States)

    2011-12-28

    .... Government-granted security clearance (i.e., Top Secret, Secret, or Confidential). d. A review of the...'' clearances or possess another active U.S. Government granted security clearance, i.e., Top Secret, Secret or...'' clearances or possess another active U.S. Government granted security clearance, i.e., Top Secret, Secret or...

  12. Comparison of measurements of plasma clearance of Mebrofenine and of indocyanine green

    International Nuclear Information System (INIS)

    Maurel, G.; Coutris, G.; Vaubourdolle, M.; Attal, P.; Patureau, R.; Tabsoba, Th.; Mensch, B.; Askienazy, Pr.S.

    1997-01-01

    The importance of clearance measurements in evaluating renal or hepatic function needs not further demonstration. The isotopic methods were proved in renal exploration but their utilization in exploration of hepato-biliary function needs to be evaluated. In this work we have compared the measurement of plasma clearance by Mebrofenine, a radiopharmaceutical of specifically hepatic elimination, with the reference method, the clearance of indocyanine green. On the basis of scintigraphic data from 23 patients who benefited by a hepato-biliary exploration by Mebrofenine- 99m Tc for pre-surgery account and surveillance, we have determined the plasma clearance of this radiopharmaceutical. The method makes use of the curve of normalized cardiac activity by a blood sampling, taken 60 minutes after injection. The measurement of the clearance of indocyanine green was effected within a delay inferior to 1 month from the moment of biliary scintigraphy. The average clearance of Mebrofenine- 99m Tc is of 553 ml/min for 1.73 m 2 of corporal surface (typical interval is 374 ml/min), the value of indocyanine green is of 450 ml/min (typical interval is 229 ml/min). The two measurements of clearance are correlated (p = 0.05). In conclusion, the measurement of clearance by Mebrofenine- 99m appears to be adapted to the evaluation of hepato-biliary function

  13. 48 CFR 1432.502-2 - Contract finance office clearance.

    Science.gov (United States)

    2010-10-01

    ... 48 Federal Acquisition Regulations System 5 2010-10-01 2010-10-01 false Contract finance office clearance. 1432.502-2 Section 1432.502-2 Federal Acquisition Regulations System DEPARTMENT OF THE INTERIOR... finance office clearance. The CO shall obtain approval of the bureau finance office prior to taking...

  14. Determining vancomycin clearance in an overweight and obese population.

    Science.gov (United States)

    Leong, Julie V B; Boro, Maureen S; Winter, Michaele

    2011-04-01

    Two methods of calculating vancomycin clearance were compared to determine the best body weight measure to use when dosing vancomycin for overweight and obese patients. Hospitalized veterans weighing more than 120% of their ideal body weight (IBW) with serum vancomycin concentrations (SVCs) drawn between January 1, 2003, and June 30, 2005, were eligible for study inclusion. Exclusion criteria included weight of more than 300% the IBW, unstable renal function, dialysis, uncertain vancomycin dosing or sampling times, and distribution-phase sampling. Data from January 1 through December 31, 2003 (phase 1) determined the best-fit weight for vancomycin clearance for the Leonard and Boro method. The bias and precision of the modified Leonard and Boro method using the best-fit weight for vancomycin clearance were then compared with those of the Rushing and Ambrose method for predicting SVCs from January 1, 2004, through June 30, 2005 (phase 2). Forty-eight patients were included in phase 1, with 67 SVCs for analysis. During phase 1, adjusted body weight (ABW), using the Leonard and Boro method, was superior in predicting vancomycin clearance and the resultant SVCs. A total of 96 patients were included in phase 2 of the study, with 160 SVCs for analysis. The modified Leonard and Boro method was significantly more precise than the Rushing and Ambrose method in predicting vancomycin clearance. Use of ABW proved to be superior compared with total body weight when estimating vancomycin clearance in overweight and obese patients. While there was no difference in bias between methods, the modified Leonard and Boro method was significantly more precise than the Rushing and Ambrose method in predicting SVCs when dosing vancomycin for obese patients.

  15. Tip clearance effect on through-flow and performance of a centrifugal compressor

    International Nuclear Information System (INIS)

    Eum, Hark Jin; Kang, Young Seok; Kang, Shin Hyoung

    2004-01-01

    Numerical simulations have been performed to investigate tip clearance effect on through-flow and performance of a centrifugal compressor which has the same configuration of impeller with six different tip clearances. Secondary flow and loss distribution have been surveyed to understand the flow mechanism due to the tip clearance. Tip leakage flow strongly interacts with mainstream flow and considerably changes the secondary flow and the loss distribution inside the impeller passage. A method has been described to quantitatively estimate the tip clearance effect on the performance drop and the efficiency drop. The tip clearance has caused specific work reduction and additional entropy generation. The former, which is called inviscid loss, is independent of any internal loss and the latter, which is called viscous loss, is dependent on every loss in the flow passage. Two components equally affected the performance drop as the tip clearances were small, while the efficiency drop was influenced by the viscous component alone. The additional entropy generation was modeled with all the kinetic energy of the tip leakage flow. Therefore, the present paper can provide how to quantitatively estimate the tip clearance effect on the performance and efficiency

  16. Tear clearance implications for ocular surface health.

    Science.gov (United States)

    de Paiva, Cintia Sade; Pflugfelder, Stephen C

    2004-03-01

    Tear clearance/turnover provides a global assessment of the function of the lacrimal functional unit and of tear exchange on the ocular surface. It is an indirect measure of dry eye induced inflammation on the ocular surface. It shows better correlation with the severity of ocular irritation symptoms and corneal epithelial disease in dry eye than the Schirmer 1 test. Delayed tear clearance may prove to be the best measure for identifying patients with tear film disorders who may respond to anti-inflammatory therapy.

  17. Clearance of Tc-99m DTPA in hemodialysis and peritoneal dialysis: concise communication

    International Nuclear Information System (INIS)

    Wainer, E.; Boner, G.; Lubin, E.; Rosenfeld, J.B.

    1981-01-01

    The clearance of Tc-99m DTPA was studied in 14 patients undergoing hemodialysis (HD) or peritoneal dialysis (PD). Mean Tc-99m DTPA clearance during HD was 37.8% +/- 10.1 of creatinine clearance. Mean Tc-99m DTPA clearance in PD was 65.1% +/- 10.3 of creatinine clearance. Tc-99m DTPA, with a larger molecular weight than that of creatinine, is cleared relatively better during PD than during HD. Thus Tc-99m DTPA may be used in the assessment of the effectiveness of different dialytic treatments for substances of similar molecular weight. In addition, our study shows that clearance of DTPA both in HD and PD is sufficiently high to allow the removal of this chelating agent in patients with renal failure

  18. Effect of isolated hepatic ischemia on organic anion clearance and oxidative metabolism.

    Science.gov (United States)

    Minard, G; Bynoe, R; Wood, G C; Fabian, T C; Croce, M; Kudsk, K A

    1992-04-01

    Hepatic failure is frequently seen following severe hemorrhagic shock, sepsis, and trauma. Clearance of various drugs has been used to evaluate hepatocellular dysfunction, including indocyanine green (ICG), an organic anionic dye that is transported similarly to bilirubin, and antipyrine (AP), a marker of oxidative phosphorylation. Previous investigators have noted a decrease in ICG excretion following systemic hemorrhage. The effect of isolated hepatic ischemia on the clearances of ICG and AP was studied in 16 pigs after 90 minutes of vascular occlusion to the liver. Antipyrine clearance decreased almost 50% from baseline values at 24 and 72 hours after the ischemia procedure, indicating a significant depression in the cytochrome P-450 system. On the other hand, ICG clearance did not change significantly. In conclusion, ICG clearance is not depressed after isolated hepatic ischemia in pigs. Changes in organic anion clearance after systemic hemorrhage may be because of release of toxic products from ischemic peripheral tissue.

  19. Clearance of 99mTc-DTPA and experimentally increased alveolar surfactant content

    International Nuclear Information System (INIS)

    Bos, J.A.H.; Wollmer, P.; Bakker, W.; Hannappel, E.; Lachmann, B.

    1992-01-01

    The authors measured clearance of 99m Tc-labeled diethylenetriamine pentaacetic acid ( 99m Tc-DTPA) in rabbits with experimentally increased alveolar surfactant content. In one group of animals, surfactant production was increased by treatment with ambroxol, and another group of animals was treated with tracheal instillation of natural surfactant. A group of untreated control animals and animals treated with instillation of saline were also studied. Clearance was measured during standard conditions of mechanical ventilation and during ventilation with large tidal volumes. In ambroxol- and surfactant-treated groups, clearance rate was reduced compared with untreated control animals. In contrast, clearance rate increased after saline instillation. The differences were observed at both modes of ventilation. The findings indicate that the pulmonary surfactant system is a rate-limiting factor for the clearance of 99m Tc-DTPA and that the volume dependence of clearance is not explained by stretching of the alveolar wall only. 28 refs., 2 figs., 1 tab

  20. Domiciliary humidification improves lung mucociliary clearance in patients with bronchiectasis.

    Science.gov (United States)

    Hasani, A; Chapman, T H; McCool, D; Smith, R E; Dilworth, J P; Agnew, J E

    2008-01-01

    Inspired air humidification has been reported to show some benefit in bronchiectatic patients. We have investigated the possibility that one effect might be to enhance mucociliary clearance. Such enhancement might, if it occurs, help to lessen the risks of recurrent infective episodes. Using a radioaerosol technique, we measured lung mucociliary clearance before and after 7 days of domiciliary humidification. Patients inhaled high flow saturated air at 37 degrees C via a patient-operated humidification nasal inhalation system for 3 h per day. We assessed tracheobronchial mucociliary clearance from the retention of (99m)Tc-labelled polystyrene tracer particles monitored for 6 h, with a follow-up 24-h reading. Ten out of 14 initially recruited patients (age 37-75 years; seven females) completed the study (two withdrew after their initial screening and two prior to the initial clearance test). Seven patients studied were non-smokers; three were ex-smokers (1-9 pack-years). Initial tracer radioaerosol distribution was closely similar between pre- and post-treatment. Following humidification, lung mucociliary clearance significantly improved, the area under the tracheobronchial retention curve decreased from 319 +/- 50 to 271 +/- 46%h (p humidification treatment improved lung mucociliary clearance in our bronchiectatic patients. Given this finding plus increasing laboratory and clinical interest in humidification mechanisms and effects, we believe further clinical trials of humidification therapy are desirable, coupled with analysis of humidification effects on mucus properties and transport.

  1. 48 CFR 245.7101-4 - DD Form 1640, Request for Plant Clearance.

    Science.gov (United States)

    2010-10-01

    ... 48 Federal Acquisition Regulations System 3 2010-10-01 2010-10-01 false DD Form 1640, Request for Plant Clearance. 245.7101-4 Section 245.7101-4 Federal Acquisition Regulations System DEFENSE... Forms 245.7101-4 DD Form 1640, Request for Plant Clearance. Use to request plant clearance assistance or...

  2. Impairment of nasal mucociliary clearance in woodworkers in the furniture industry

    Science.gov (United States)

    Black, A.; Evans, J. C.; Hadfield, Esme H.; Macbeth, R. G.; Morgan, A.; Walsh, M.

    1974-01-01

    Black, A., Evans, J. C., Hadfield, Esme H., Macbeth, R. G., Morgan, A., and Walsh, M. (1974).British Journal of Industrial Medicine,31, 10-17. Impairment of nasal mucociliary clearance in woodworkers in the furniture industry. Measurements of mucociliary clearance from the anterior end of the middle turbinate were made using technetium-99m-labelled particles in nine woodworkers from the furniture industry and in 12 controls, none of whom had been occupationally exposed to wood dust. Clearance rates in the controls ranged from 1·9 to 18·5 mm min-1 with a mean of 6·8. These values are in good agreement with measurements reported elsewhere for normal subjects. Only one of the woodworkers had a clearance rate which fell within the normal range and he had been occupationally exposed for the shortest period (6 years). In four woodworkers clearance was very slow (furniture industry for more than 10 years. PMID:4821406

  3. Renal clearance of 99mTc-methylene-diphosphonate in human beings

    International Nuclear Information System (INIS)

    Vattimo, A.

    1987-01-01

    The renal clearance of 99m Tc-MDP was measured in 13 patients who had bone scans and compared with the renal clearance of 51 Cr-EDTA. No difference was found between the renal clearance of the two tracers, showing a close correlation (r = 0.98). These data suggest that the 99m Tc-MDP is excreted by the kidneys by glomerular filtration without tubular secretion. (orig.) [de

  4. Exercise increases the lung clearance of inhaled Tc-99m DTPA

    International Nuclear Information System (INIS)

    Meignan, M.; Rosso, J.; Cinotti, L.; Galle, P.

    1985-01-01

    It has been suggested that blood flow have little effect on the lung clearance of Tc-99m DTPA which depends on the alveolar distension. However an increase of pulmonary blood flow, induces a recruitment of new vascular areas which can enhance this clearance. To assess this hypothesis the pulmonary apical and basal clearances of a sumicronic aerosol of Tc-99m DTPA were studied at rest and at exercise in seven non smoking volunteers in upright posture. As a matter of fact exercising upright is known to increase primarily the apical blood flow. After inhalation the subjects were seated on a bicycle their back against a gamma camera which was linked to a computer. The lung radioactivity was registered successively during a resting and an exercising period. At rest there was a gradient of clearance from the apex to the base of the lung, the apical clearance being significantly higher. At exercise (50 Watts, 60 c. min /sup -1/, 7 min.) this regional gradient was enhanced by a large and significant increase of the apical clearances (0.0340 min /sup -1/ +-0.0063 SD versus 0.00183 min /sup -1/ +- 0.074 SD at rest, n = 7, p < 0.01). By contrast the changes of the basal clearances were slight and unsignificant (0.0146 min /sup -1/ +- 0.0062 SD versus 0.0140 min /sup -1/ +- 0.0082 SD). Since exercise induces little distension of the apical alveoli but drastically enhances the apical blood flow, the observed increase of the apical lung clearance could be primarily attributed to the recruitment of new capillaries induced by exercise in the apices. This led to an increase of the surface area permeability product

  5. Oxygen Tension Beneath Scleral Lenses of Different Clearances.

    Science.gov (United States)

    Giasson, Claude J; Morency, Jeanne; Melillo, Marc; Michaud, Langis

    2017-04-01

    To evaluate the relative partial pressure in oxygen (pO2) at the corneal surface under Boston XO2 scleral lenses (SL) fitted with targeted clearances of 200 and 400 μm (SL200 and SL400). During this prospective study, the right eyes of eight normal subjects were fitted with SL200 and SL400. Clearance, validated after 5 minutes of wear with an optical coherence tomograph, was used with lens thicknesses to calculate transmissibility and estimate pO2. Corneal pO2s were measured with an oxygen electrode after 5 minutes of (1) corneal exposure to calibrating gases with various pO2 or of (2) SL wear. Decays in pO2 were modeled to an exponential. Linear regression between exponent k of these decays and calibrating gas pO2s allowed for the calculation of corneal pO2 under SL. Differences between pO2s beneath SL200 and SL400 were tested with a mixed ANOVA. The estimated transmissibility based on thicknesses and clearances (239.7 ± 34.7; 434.5 ± 33.2 μm) predicted a corneal pO2 of 8.52 ± 0.51 and 6.37 ± 0.28% for SL200 and SL400. These values were close to measured pO2: 9.07 ± 0.86 and 6.19 ± 0.87% (mean ± SEM) (P time, an 18-mm scleral lens fitted with a 400-μm clearance reduces the oxygen tension available to the cornea by 30% compared to a similar lens fitted with a 200-μm clearance after 5 minutes of wear.

  6. Acute exposure to acid fog. Effects on mucociliary clearance

    International Nuclear Information System (INIS)

    Laube, B.L.; Bowes, S.M. III; Links, J.M.; Thomas, K.K.; Frank, R.

    1993-01-01

    Submicrometric sulfuric acid (H2SO4) aerosol can affect mucociliary clearance without eliciting irritative symptoms or changes in pulmonary function. The effect of larger fog droplets containing H2SO4 on mucociliary clearance is unknown. We quantified mucociliary clearance from the trachea (n = 4) and small airways (n = 7) of young healthy male adults after an acute exposure to H2SO4 fog (MMAD = 10.3 microns; pH = 2.0; liquid water content = 481 +/- 65 mg/m3; osmolarity = 30 mOsm). Acid fog (AF) or saline fog (SF) (10.9 microns; 492 +/- 116 mg/m3; 30 mOsm) was administered for 40 min of unencumbered breathing (no mouth-piece) at rest and for 20 min of exercise sufficient to produce oronasal breathing. Fog exposures were followed by a methacholine (MCh) challenge (a measure of airway reactivity) or inhalation of technetium-99M radioaerosol (MMAD = 3.4 microns) on 2 study days each. Changes in symptoms and forced ventilatory function were also assessed. Clearance was quantified from computer-assisted analyses of gamma camera images of the lower respiratory tract in terms of %removal/min of the radiolabel from the trachea 25 min after inhalation and from the outer zone of the right lung after 1.9 to 3 h. Symptoms, forced ventilatory function, and MCh response were unaffected by either fog. Tracheal clearance was more rapid in four of four subjects after AF (0.83 +/- 1.58% removal/min) compared with that after SF (-0.54 +/- 0.85% removal/min). Outer zone clearance was more rapid in six of seven subjects after AF (0.22 +/- 0.15% removal/min) compared with that after SF (0.01 +/- 0.09% removal/min)

  7. 20 CFR 655.150 - Interstate clearance of job order.

    Science.gov (United States)

    2010-04-01

    ... 20 Employees' Benefits 3 2010-04-01 2010-04-01 false Interstate clearance of job order. 655.150... job order. (a) SWA posts in interstate clearance system. The SWA must promptly place the job order in... transmit a copy of its active job order to all States listed in the job order as anticipated worksites...

  8. Dimerization of glycoprotein Ibα is not sufficient to induce platelet clearance.

    Science.gov (United States)

    Liang, X; Syed, A K; Russell, S R; Ware, J; Li, R

    2016-02-01

    ESSENTIALS: Many anti-glycoprotein (GP)Ibα antibodies induce platelet clearance in a dimer-dependent manner. Characterization of monoclonal antibodies that bind the mechanosensitive domain (MSD) of GPIbα. An anti-MSD antibody binds two copies of GPIbα in platelets but does not induce platelet clearance. The prevailing clustering model of GPIbα signaling is incorrect or needs revision. The mechanism of platelet clearance is not clear. Many antibodies binding the membrane-distal ligand-binding domain of glycoprotein (GP)Ibα induce rapid clearance of platelets and acute thrombocytopenia, which requires the bifurcated antibody structure. It was thought that binding of these antibodies induced lateral dimerization or clustering of GPIbα in the plasma membrane, which leads to downstream signaling and platelet clearance. However, many antibodies targeting GPIbβ and GPIX, which are associated with GPIbα in the GPIb-IX complex, do not induce platelet clearance, which is in contradiction to the clustering model. To test whether dimerization or clustering of GPIbα is sufficient to transmit the signal that leads to platelet clearance. We have recently raised several mAbs targeting the mechanosensitive domain (MSD) of GPIbα. Binding of these anti-MSD antibodies was characterized with biochemical methods. Their ability to stimulate platelets and induce platelet clearance in mice was assessed. Infusion of anti-MSD antibodies does not cause thrombocytopenia in mice. These antibodies show no detectable effects on platelet activation and aggregation in vitro. Further biochemical investigation showed that the anti-MSD antibody 3D1 binds two copies of GPIbα on the platelet surface. Therefore, lateral dimerization of GPIbα induced by antibody binding is not sufficient to initiate GPIb-IX signaling and induce platelet clearance. Our results suggest that a factor other than or in addition to clustering of GPIbα is required to induce platelet clearance. © 2015 International

  9. HPT Clearance Control: Intelligent Engine Systems-Phase 1

    Science.gov (United States)

    2005-01-01

    The following work has been completed to satisfy the Phase I Deliverables for the "HPT Clearance Control" project under NASA GRC's "Intelligent Engine Systems" program: (1) Need for the development of an advanced HPT ACC system has been very clearly laid out, (2) Several existing and potential clearance control systems have been reviewed, (3) A scorecard has been developed to document the system, performance (fuel burn, range, payload, etc.), thermal, and mechanical characteristics of the existing clearance control systems, (4) Engine size and flight cycle selection for the advanced HPT ACC system has been reviewed with "large engine"/"long range mission" combination showing the most benefit, (5) A scoring criteria has been developed to tie together performance parameters for an objective, data driven comparison of competing systems, and (6) The existing HPT ACC systems have been scored based on this scoring system.

  10. Estimation of normal chromium-51 ethylene diamine tetra-acetic acid clearance in children

    International Nuclear Information System (INIS)

    Piepsz, A.; Pintelon, H.; Ham, H.R.

    1994-01-01

    In order to estimate the normal range of chromium-51 ethylene diamine tetra-acetic acid (EDTA) clearance in children, we selected a series of 256 patients with past or present urinary tract infection who showed, at the time of the clearance determination, normal technetium-99m dimercaptosuccinic acid (DMSA) scintigraphy and normal left to right DMSA relative uptake. The clearance was calculated by means of either the simplified second exponential method or the 120-min single blood sample; Chantler's correction was used in order to correct for having neglected the first exponential. There was a progressive increase in clearance from the first weeks of life (mean value around 1 month: 55 ml/min/1.73 m 2 ), with a plateau at around 18 months. Between 2 and 17 years of age, the clearance values remained constant, with a mean value of 114 ml/min/1.73 m 2 (SD: 24 ml/min); this is similar to the level described for inulin clearance. No significant differences were observed between boys and girls, or between clearance values calculated with one or with two blood samples. Taking into account the hour of intravenous injection of the tracer, we did not observe any influence of the lunchtime meal on the distribution of the 51 Cr-EDTA clearance values. (orig.)

  11. Effect of prior immobilization on muscular glucose clearance in resting and running rats

    International Nuclear Information System (INIS)

    Vissing, J.; Ohkuwa, Tetsuo; Ploug, T.; Galbo, H.

    1988-01-01

    In vitro studies have shown that prior disuse impairs the glucose clearance of red skeletal muscle because of a developed insensitivity to insulin. We studied whether an impaired glucose clearance is present in vivo in 42-h immobilized muscles of resting rats and, furthermore, whether the exercise-induced increase in glucose clearance of red muscles is affected by prior immobilization. The 2-[ 3 H]deoxy-D-glucose (2DG) bolus injection method was used to determine glucose clearance of individual muscles. At rest, glucose clearance was markedly impaired in rats with previously immobilized red muscles compared with nonimmobilized control rats. During running, glucose clearance did not differ between muscles in previously immobilized and control rats. Insulin levels were always similar in the two groups and decreased during exercise. Intracellular nonphosphorylated 2DG was present in tissues with high glucose clearances. In conclusion, 42 h of immobilization markedly impairs glucose clearance of resting red muscle fibers in vivo. Apparently, physical inactivity in particular affects steps involved in insulin-mediated action that are not part of contraction-induced glucose uptake and metabolism. Presence of intracellular 2DG shows that separate determination of phosphorylated 2DG is necessary for accurate estimates of glucose metabolism and that accumulation of phosphorylated 2DG does not accurately reflect glucose transport

  12. Analysis of foot clearance in firefighters during ascent and descent of stairs.

    Science.gov (United States)

    Kesler, Richard M; Horn, Gavin P; Rosengren, Karl S; Hsiao-Wecksler, Elizabeth T

    2016-01-01

    Slips, trips, and falls are a leading cause of injury to firefighters with many injuries occurring while traversing stairs, possibly exaggerated by acute fatigue from firefighting activities and/or asymmetric load carriage. This study examined the effects that fatigue, induced by simulated firefighting activities, and hose load carriage have on foot clearance while traversing stairs. Landing and passing foot clearances for each stair during ascent and descent of a short staircase were investigated. Clearances decreased significantly (p < 0.05) post-exercise for nine of 12 ascent parameters and increased for two of eight descent parameters. Load carriage resulted in significantly decreased (p < 0.05) clearance over three ascent parameters, and one increase during descent. Decreased clearances during ascent caused by fatigue or load carriage may result in an increased trip risk. Increased clearances during descent may suggest use of a compensation strategy to ensure stair clearance or an increased risk of over-stepping during descent. Copyright © 2015 Elsevier Ltd and The Ergonomics Society. All rights reserved.

  13. Activation and clearance of vanadium alloys and beryllium multipliers in fusion reactors

    International Nuclear Information System (INIS)

    Bartenev, S.; Romanovskij, V.; Ciampichetti, A.; Zucchetti, M.; Forrest, R.; Kolbasov, B.; Romanov, P.

    2006-01-01

    Design of fusion reactors includes the development of low-activation materials. V-Cr-Ti alloys are among the candidate structural materials for the first wall and blanket, with the scarce and costly V as the main component. It is worth considering its regeneration and refabrication as well as to avoid its disposal as radioactive waste. However, to do so, it is necessary to bring its radioactivity down to sufficiently low levels. We have two possible goals: · Recycling (within the nuclear industry) for first wall and front blanket components. In that case, contact dose rate must be sufficiently low. · Clearance (release from nuclear regulatory control) for back blanket and backplate components. In that case, the clearance index must be below unity. In fact, for components less exposed to neutron activation, clearance may be reachable, after a conceivable period of decay. Maximum radionuclide concentrations in the alloys allowing their clearance were determined, using new IAEA Clearance Limits. For this purpose, also for less neutron-exposed structures, such as the back part of the blanket and the backplate, clearance is possible only if certain activation products are separated. As for recycling within the nuclear industry of first wall components, also for clearance it turns out that the development of isotope chemical separation techniques is interesting and necessary for our purposes. A suitable method for achieving the required substantial radioactivity reduction of activated V-Cr-Ti alloys is radiochemical extraction reprocessing, Such a technology, permitting to remove metallic activation products from spent materials, was developed and tested experimentally in Russia. Concerning clearance of less activated components, based on the estimated element distribution factors in the extraction and re-extraction processes, and computations, it was shown that the alloy components may be purified from the activation products, using this technology, down to an

  14. Airway Clearance Techniques (ACTs)

    Medline Plus

    Full Text Available ... NACFC Carolyn and C Richard Mattingly Leadership in Mental Health Care Award Mary M. Kontos Award NACFC Reflections ... help your infant or child manage their lung health, watch parents of children with CF and a respiratory therapist talk about the different techniques they use for airway clearance. ... Instagram Email Find a Clinical Trial Help us blaze ...

  15. 7 CFR 1927.53 - Costs of title clearance and closing of transactions.

    Science.gov (United States)

    2010-01-01

    ... 7 Agriculture 12 2010-01-01 2010-01-01 false Costs of title clearance and closing of transactions... and Loan Closing § 1927.53 Costs of title clearance and closing of transactions. The borrower or the... payment of all costs of title clearance and closing of the transaction and will arrange for payment before...

  16. Experimental Investigation of Factors Influencing Operating Rotor Tip Clearance in Multistage Compressors

    Directory of Open Access Journals (Sweden)

    Reid A. Berdanier

    2015-01-01

    Full Text Available An analysis of compressor rotor tip clearance measurements using capacitance probe instrumentation is discussed for a three-stage axial compressor. Thermal variations and centrifugal effects related to rotational speed changes affect clearance heights relative to the assembled configuration. These two primary contributions to measured changes are discussed both independently and in combination. Emphasis is given to tip clearance changes due to changing loading condition and at several compressor operating speeds. Measurements show a tip clearance change approaching 0.1 mm (0.2% rotor span when comparing a near-choke operating condition to a near-stall operating condition for the third stage. Additional consideration is given to environmental contributions such as ambient temperature, for which changes in tip clearance height on the order of 0.05 mm (0.1% rotor span were noted for temperature variations of 15°C. Experimental compressor operating clearances are presented for several temperatures, operating speeds, and loading conditions, and comparisons are drawn between these measured variations and predicted changes under the same conditions.

  17. USING TERRESTRIAL LASER SCANNERS TO CALCULATE AND MAP VERTICAL BRIDGE CLEARANCE

    OpenAIRE

    C. Zhang; D. Arditi; Z. Chen

    2013-01-01

    The vertical clearance of a bridge over a highway is important in preventing oversized vehicles from hitting the bridge. The vertical clearance of a bridge is traditionally measured by using surveying equipment such as leveling rods and total stations. Typically, measurements are taken at multiple locations in order to determine the minimum vertical clearance under the bridge. This process is time and labor consuming. Also, these measurements may not be accurate because of the traffi...

  18. Brain-wide pathway for waste clearance captured by contrast-enhanced MRI

    OpenAIRE

    Iliff, Jeffrey J.; Lee, Hedok; Yu, Mei; Feng, Tian; Logan, Jean; Nedergaard, Maiken; Benveniste, Helene

    2013-01-01

    The glymphatic system is a recently defined brain-wide paravascular pathway for cerebrospinal fluid (CSF) and interstitial fluid (ISF) exchange that facilitates efficient clearance of solutes and waste from the brain. CSF enters the brain along para-arterial channels to exchange with ISF, which is in turn cleared from the brain along para-venous pathways. Because soluble amyloid β clearance depends on glymphatic pathway function, we proposed that failure of this clearance system contributes t...

  19. Gamma-variate plasma clearance versus urinary plasma clearance of 51Cr-EDTA in patients with cirrhosis with and without fluid retention

    DEFF Research Database (Denmark)

    Fuglsang, Stefan; Henriksen, Ulrik L; Hansen, Hanne Boskov

    2017-01-01

    In patients with fluid retention, the plasma clearance of (51) Cr-EDTA (Clexp obtained by multiexponential fit) may overestimate the glomerular filtration rate (GFR). The present study was undertaken to compare a gamma-variate plasma clearance (Clgv) with the urinary plasma clearance of (51) Cr......-EDTA (Clu ) in patients with cirrhosis with and without fluid retention. A total of 81 patients with cirrhosis (22 without fluid retention, 59 with ascites) received a quantitative intravenous injection of (51) Cr-EDTA followed by plasma and quantitative urinary samples for 5 h. Clgv was determined from...... the injected dose relative to the plasma concentration-time area, obtained by a gamma-variate iterative fit. Clexp and Clu were determined by standard technique. In patients without fluid retention, Clgv , Clexp and Clu were closely similar. The difference between Clgv and Clu (Clgv - Clu = ΔCl) was mean -0...

  20. Measurement of single kidney contrast media clearance by multiphasic spiral computed tomography: preliminary results

    International Nuclear Information System (INIS)

    Hackstein, N.; Puille, M.F.; Bak, Benjamin H.; Scharwat, Oliver; Rau, W.S.

    2001-01-01

    Objective. We present preliminary results of a new method (hereinafter called 'CT-clearance') to measure single kidney contrast media clearance by performing multiphasic helical CT of the kidneys. CT-clearance was calculated according to an extension of the Patlak-Plot. In contrast to prior investigators, who repeatedly measured a single slice, this method makes it possible to calculate single kidney clearance from at least three spiral CTs, utilizing the whole kidney volume. Methods. Spiral CT of the kidneys was performed unenhanced and about 30 and 100 s after administration of about 120 ml iopromide. Sum-density of the whole kidneys and aortic density was calculated from this data. Using this data, renal clearance of contrast media was calculated by CT-clearance in 29 patients. As reference, Serum-clearance was calculated in 24 patients by application of a modified one-exponential slope model. Information on the relative kidney function was gained by renal scintigraphy with Tc99m-MAG-3 or Tc99m-DMSA in 29 patients. Results. Linear regression analysis revealed a correlation coefficient of CT-clearance with Serum-clearance of r=0.78 with Cl (CT) [ml/min]=22.2+1.03 * Cl (serum), n=24. Linear regression of the relative kidney function (rkf) of the right kidney calculated by CT-clearance compared to scintigraphy results provided a correlation coefficient r=0.89 with rkf(CT)[%]=18.6+0.58 * rkf(scintigraphy), n=29. Conclusion. The obtained results of contrast media clearance measured by CT-clearance are in the physiological range of the parameter. Future studies should be performed to improve the methodology with the aim of higher accuracy. More specifically, better determination of the aortic density curve might improve the accuracy

  1. Lung clearance of {sup 99m} Tc- DTPA in systemic lupus erythematous

    Energy Technology Data Exchange (ETDEWEB)

    Dalcin, P.T.R; Barreto, S.S.M.; Xavier, R.M.; Brenol, J.C.T. [Rio Grande do Sul Univ., Porto Alegre, RS (Brazil). Hospital de Clinicas. Dept. de Medicina Interna; Cunha, R.D.; Marroni, B.J. [Rio Grande do Sul Univ., Porto Alegre, RS (Brazil). Hospital de Clinicas. Servico de Medicina Nuclear]. E-mail: rxavier@hcpa.ufrgs.br

    2002-06-01

    The early demonstration of lung involvement in systemic lupus erythematosus (SLE) patients is a difficult but important task. In the present study we attempted to identify abnormalities in pulmonary clearance of 99 mTc-DTPA in SLE, correlating their clearance data with clinical findings and disease activity. Forty-six consecutive SLE patients with and without active disease (LACC score) and 30 normal volunteers were studied. All subjects were submitted to pulmonary scintigraphy with 99 mTc-DTPA to evaluate the pulmonary clearance, and to a chest X-ray, and SLE patients were submitted to tests of disease activity, spirometry, arterial blood gases and tests to assess acute-phase proteins. Pulmonary clearance was faster in SLE patients with active disease when compared to normal controls [half-life of 67.04 min (51.52-82.55 min) in active SLE versus 85.87 min (78.85-92.87 min) in controls, P<0.05] and there was a higher frequency of abnormal clearance rates in patients with active disease (11 of 26 patients, 42.3%) when compared with SLE patients without disease activity (2 of 20 patients, 10%) (P = 0.04). A significant correlation was observed between the clearance rates and cough (P<0.05), but not between the clearance rates and dyspnoea symptoms or radiological findings, duration of SLE disease, antinuclear antibody titers and patterns, C-reactive protein or anti-double stranded DNA antibodies. We conclude that the pulmonary clearance of 99 m Tc-DTPA is increased in SLE patients with active disease. (author)

  2. Comparison of arterial intimal clearances of LDL from diabetic and nondiabetic cholesterol-fed rabbits. Differences in intimal clearance explained by size differences

    International Nuclear Information System (INIS)

    Nordestgaard, B.G.; Zilversmit, D.B.

    1989-01-01

    Arterial intimal clearances of low density lipoproteins (LDL) from diabetic cholesterol-fed rabbits (D-LDL) and LDL from nondiabetic cholesterol-fed rabbits (N-LDL) were compared. In six experiments, D-LDL and N-LDL were isolated from a diabetic and a nondiabetic rabbit, were iodinated with 125I and 131I, respectively, were mixed, and were reinjected into the same two rabbits as well as into a normal rabbit. Fractional catabolic rates for D-LDL and N-LDL in normal rabbits were 0.065 and 0.074 h-1 (p less than 0.05), respectively. For five of the six pairs of LDL, the D-LDL was smaller than N-LDL as determined by gel filtration. The arterial permeability to N-LDL, when normalized for differences in arterial cholesterol content, did not appear to differ between diabetic and nondiabetic rabbits. The relative arterial intimal clearance (D-LDL/N-LDL) in arteries from diabetic and nondiabetic rabbits was inversely related to the relative molecular weight (D-LDL/N-LDL). For example, when the molecular weight of D-LDL was as low as 60% of that of N-LDL (i.e., the diameter of D-LDL was reduced 16%), the intimal clearance of D-LDL was 40% larger than that of N-LDL. When, on the other hand, molecular weights and diameters of the two LDL were similar, the intimal clearance was also quite similar. These results suggest that arterial intimal clearance of LDL from diabetic and nondiabetic cholesterol-fed rabbits is comparable unless the two types of LDL have a different size

  3. Clearance of the cervical spine in clinically unevaluable trauma patients.

    Science.gov (United States)

    Halpern, Casey H; Milby, Andrew H; Guo, Wensheng; Schuster, James M; Gracias, Vicente H; Stein, Sherman C

    2010-08-15

    Meta-analytic costeffectiveness analysis. Our goal was to compare the results of different management strategies for trauma patients in whom the cervical spine was not clinically evaluable due to impaired consciousness, endotracheal intubation, or painful distracting injuries. We performed a structured literature review related to cervical spine trauma, radiographic clearance techniques (plain radiography, flexion/extension, CT, and MRI), and complications associated with semirigid collar use. Meta-analytic techniques were used to pool data from multiple sources to calculate pooled mean estimates of sensitivities and specificities of imaging techniques for cervical spinal clearance, rates of complications from various clearance strategies and from empirical use of semirigid collars. A decision analysis model was used to compare outcomes and costs among these strategies. Slightly more than 7.5% of patients who are clinically unevaluable have cervical spine injuries, and 42% of these injuries are associated with spinal instability. Sensitivity of plain radiography or fluoroscopy for spinal clearance was 57% (95% CI: 57%-60%). Sensitivities for CT and MRI alone were 83% (82%-84%) and 87% (84%-89%), respectively. Complications associated with collar use ranged from 1.3% (2 days) to 7.1% (10 days) but were usually minor and short-lived. Quadriplegia resulting from spinal instability missed by a clearance test had enormous impacts on longevity, quality of life, and costs. These impacts overshadowed the effects of prolonged collar application, even when the incidence of quadriplegia was extremely low. As currently used, neuroimaging studies for cervical spinal clearance in clinically unevaluable patients are not cost-effective compared with empirical immobilization in a semirigid collar.

  4. Clearance of slightly radioactive material from radiological control in Germany

    International Nuclear Information System (INIS)

    Thierfeldt, S.

    1995-01-01

    Clearance from radiological control of slightly radioactive material arising from operation or decommissioning of nuclear installations has been practiced in Germany for nearly two decades. Meanwhile, for the clearance of metal generally approved and applicable recommendations for clearance levels have been issued. For other materials like building waste, case-by-case decisions are made by the state licensing authorities. Efforts to implement consistent sets of clearance levels for all kinds of material are under way. As several decommissioning projects will soon generate large amounts of materials from dismantling, a solution needs to be reached soon. The legal framework in Germany governing the use of atomic energy consists of the Atomic Energy Act and several ordinances. Rules and guidelines including the recommendations of the German Commission for Radiation Protection (SSK) exist on a lower level and are not legally binding. Several generic studies for the derivation of clearance levels for metals and building debris with alpha, beta, and gamma contamination have been performed on behalf of the Federal Ministry for Environment, Nature Conservation and Nuclear Safety, which oriented themselves on an individual dose of 10 microSv/a in agreement with IAEA recommendations. Stochastic models have been used for establishing the connection between specific activity of the material to be released and the resulting individual doses, with significant advantages over deterministic scenarios. In the future, for new SSK recommendations or an ordinance on clearance, the increase of masses from demolition of installations, higher recycling rates in the conventional sector and harmonization with international regulations and standards have to be taken into account

  5. Mucociliary clearance, airway inflammation and nasal symptoms in urban motorcyclists

    Directory of Open Access Journals (Sweden)

    Tereza C.S. Brant

    2014-01-01

    Full Text Available OBJECTIVES: There is evidence that outdoor workers exposed to high levels of air pollution exhibit airway inflammation and increased airway symptoms. We hypothesized that these workers would experience increased airway symptoms and decreased nasal mucociliary clearance associated with their exposure to air pollution. METHODS: In total, 25 non-smoking commercial motorcyclists, aged 18-44 years, were included in this study. These drivers work 8-12 hours per day, 5 days per week, driving on urban streets. Nasal mucociliary clearance was measured by the saccharine transit test; airway acidification was measured by assessing the pH of exhaled breath condensate; and airway symptoms were measured by the Sino-nasal Outcome Test-20 questionnaire. To assess personal air pollution exposure, the subjects used a passive-diffusion nitrogen dioxide (NO2 concentration-monitoring system during the 14 days before each assessment. The associations between NO2 and the airway outcomes were analyzed using the Mann-Whitney test and the Chi-Square test. Clinicaltrials.gov: NCT01976039. RESULTS: Compared with clearance in healthy adult males, mucociliary clearance was decreased in 32% of the motorcyclists. Additionally, 64% of the motorcyclists had airway acidification and 92% experienced airway symptoms. The median personal NO2 exposure level was 75 mg/m3 for these subjects and a significant association was observed between NO2 and impaired mucociliary clearance (p = 0.036. CONCLUSION: Non-smoking commercial motorcyclists exhibit increased airway symptoms and airway acidification as well as decreased nasal mucociliary clearance, all of which are significantly associated with the amount of exposure to air pollution.

  6. 76 FR 31992 - In the Matter of Nine Mile Point Nuclear Station, LLC; Nine Mile Point Nuclear Station...

    Science.gov (United States)

    2011-06-02

    ... another active U.S. Government-granted security clearance (i.e., Top Secret, Secret, or Confidential). d...'' clearances or possess another active U.S. Government granted security clearance, i.e., Top Secret, Secret or... another active U.S. Government granted security clearance, i.e., Top Secret, Secret or Confidential. 6...

  7. Clearance of building structures for conventional non-nuclear reuse

    International Nuclear Information System (INIS)

    Buss, K.; Boehringer, S.

    1998-01-01

    At the example of a fuel assembly plant the strategy of control measurements on building surfaces, which shall be conventionally reused after their clearance, is regarded. Based on the given clearance levels the used measuring methods, especially with regard of possibly covered or intruded uranium contamination, are shown. The possibility of using the in-situ-γ-spectroscopy is discussed. (orig.) [de

  8. CO2 clearance by membrane lungs.

    Science.gov (United States)

    Sun, Liqun; Kaesler, Andreas; Fernando, Piyumindri; Thompson, Alex J; Toomasian, John M; Bartlett, Robert H

    2018-05-01

    Commercial membrane lungs are designed to transfer a specific amount of oxygen per unit of venous blood flow. Membrane lungs are much more efficient at removing CO 2 than adding oxygen, but the range of CO 2 transfer is rarely reported. Commercial membrane lungs were studied with the goal of evaluating CO 2 removal capacity. CO 2 removal was measured in 4 commercial membrane lungs under standardized conditions. CO 2 clearance can be greater than 4 times that of oxygen at a given blood flow when the gas to blood flow ratio is elevated to 4:1 or 8:1. The CO 2 clearance was less dependent on surface area and configuration than oxygen transfer. Any ECMO system can be used for selective CO 2 removal.

  9. Dynamic analysis of cross shaft type universal joint with clearance

    International Nuclear Information System (INIS)

    Lu, Jian Wei; Wang, Gong Cheng; Chen, Hao; Vakakis, Alexander F.; Bergman, Lawrence A.

    2013-01-01

    Cross shaft type universal joint is widely used in ground vehicles to transfer torque between two intersecting axes, and its transmission feature can make a great contribution to NVH performance of the vehicle. We looked at the assembling clearance at cross shaft neck, and presented a dynamic model of cross shaft type universal joint with clearance at cross shaft neck. Two-state model is applied to describe the contact force between the cross shaft and driving joint fork based on Hertz theorem, and lumped mass method is applied to build up the dynamic model of the universal joint. Based on this model, numerical analysis is carried out to discuss the transmission feature of the universal joint with clearance at cross shaft neck, and the influence of clearance on the dynamic behavior of the system is evaluated with numerical results based on time history, power spectrum, and phase portrait. The method and conclusions presented are helpful to improvement of the transmission feature of cross shaft type universal joint.

  10. Uncertainty analysis of 99mTc-HEPIDA liver clearance determination

    International Nuclear Information System (INIS)

    Surma, M. J.

    2005-01-01

    The aim of the study was to obtain information on the accuracy and precision of 99mT c-HEPIDA hepatic (Cl H p) and plasma (Cl P l) clearances and selection of an appropriate estimator of the measurement uncertainty of a single determination of these quantities. In a simulation (Monte Carlo) experiment, it was assumed that the recorded results of plasma and hepatic clearances, as obtained from 185 patients, provided authentic information about 99mT c-HEPIDA behaviour in the body over a wide range of the clearances studied. The time-course 99mT c-HEPIDA concentration in blood plasma has been described by means of biexponential function with parameter values derived for each patient. For each patient, using these data and urinary excretion data, there had been 5000 simulations performed; in each of the latter, the directly measured numbers have been substituted by simulated ones, obtained by means of varying the real ones, using random generated values. These reflected errors of plasma and radioactive standard pipetting (from 1 to 5%) and stochasticity of counting radioactive decay (1%). The time of blood sampling and urine voiding was also varied, assuming realistic uncertainty. The varied values were then used for computation of the simulated clearances. From the 5000 calculated clearances for each patient, mean-values were calculated, as well as mean standard errors, standard deviations and mean uncertainty of measurements using a widely accepted rule of partial error propagation, and, in addition, a modified rule of the latter. Accuracy of clearance (Cl P l, Cl H p, Cl U r) determination was assessed on the basis of comparison of mean values from simulations with those from directly recorded values. Precision was identified with standard deviation of each of the 5000 simulations. The uncertainty thus obtained was compared with results of calculated traditional and modified uncertainty. There was good agreement between standard deviation of the simulations with

  11. Effect of prior immobilization on muscular glucose clearance in resting and running rats

    DEFF Research Database (Denmark)

    Vissing, J; Ohkuwa, T; Ploug, Thorkil

    1988-01-01

    with nonimmobilized control rats (red gastrocnemius 0.46 +/- 0.02 vs. 0.99 +/- 0.08 and soleus 1.10 +/- 0.30 vs. 3.97 +/- 0.54 ml.min-1.100 g-1, P less than 0.005). During running (18 m/min), glucose clearance did not differ between muscles in previously immobilized and control rats. Insulin levels were always......In vitro studies have shown that prior disuse impairs the glucose clearance of red skeletal muscle because of a developed insensitivity to insulin. We studied whether an impaired glucose clearance is present in vivo in 42-h immobilized muscles of resting rats and, furthermore, whether the exercise......-induced increase in glucose clearance of red muscles is affected by prior immobilization. The 2-[3H]deoxy-D-glucose (2DG) bolus injection method was used to determine glucose clearance of individual muscles. At rest, glucose clearance was markedly impaired in rats with previously immobilized red muscles compared...

  12. Online feedback-controlled renal constant infusion clearances in rats.

    Science.gov (United States)

    Schock-Kusch, Daniel; Shulhevich, Yury; Xie, Qing; Hesser, Juergen; Stsepankou, Dzmitry; Neudecker, Sabine; Friedemann, Jochen; Koenig, Stefan; Heinrich, Ralf; Hoecklin, Friederike; Pill, Johannes; Gretz, Norbert

    2012-08-01

    Constant infusion clearance techniques using exogenous renal markers are considered the gold standard for assessing the glomerular filtration rate. Here we describe a constant infusion clearance method in rats allowing the real-time monitoring of steady-state conditions using an automated closed-loop approach based on the transcutaneous measurement of the renal marker FITC-sinistrin. In order to optimize parameters to reach steady-state conditions as fast as possible, a Matlab-based simulation tool was established. Based on this, a real-time feedback-regulated approach for constant infusion clearance monitoring was developed. This was validated by determining hourly FITC-sinistrin plasma concentrations and the glomerular filtration rate in healthy and unilaterally nephrectomized rats. The transcutaneously assessed FITC-sinistrin fluorescence signal was found to reflect the plasma concentration. Our method allows the precise determination of the onset of steady-state marker concentration. Moreover, the steady state can be monitored and controlled in real time for several hours. This procedure is simple to perform since no urine samples and only one blood sample are required. Thus, we developed a real-time feedback-based system for optimal regulation and monitoring of a constant infusion clearance technique.

  13. Exclusion, exemption, clearance European Union approach

    International Nuclear Information System (INIS)

    Janssens, A.

    1997-01-01

    The presentation overviews the following issues: Euratom Basic Safety Standards; administrative requirements; radiation protection of the population. Scope of the Standards: natural radiation sources; exclusion. Exemption; Clearance; Import of radioactive scrap metal

  14. A simple method for the verification of clearance levels for non-radioactive solid waste

    International Nuclear Information System (INIS)

    Holland, B.

    1997-01-01

    ANSTO's radiopharmaceutical production laboratories generate 25 m 3 of solid waste per month. Most of this waste is not radioactive. Up until recently the non-radioactive waste was cleared from the controlled area and stored for 10 halflives prior to disposal as normal solid refuse. To eliminate the storage and ''double handling'' of the large quantities of non-radioactive waste a simple clearance method was devised to allow direct disposal. This paper describes how clearance levels were determined. Here the term ''clearance level'' is used as a general term for the release of material regardless of whether it was previously subject to regulatory control. This contrasts with the IAEA definition of a clearance level and highlights a potential problem with the implementation of exemption levels to keep material out of regulatory control and the use of clearance levels to allow removal of materials from regulatory control. Several common hand held contamination monitors were tested to determine their limits of detection and ability to meet these clearance levels. The clearance method includes waste segregation and size limitation features to ensure the waste is monitored in a consistent manner, compatible with the limits of detection. The clearance levels achieved were subsequently found to be compatible with some of the unconditional clearance levels in IAEA-TECDOC-855 and the measurement method also meets the required features of that document. The ANSTO non-radioactive waste clearance system has been in operation for more than 12 months and has proved simple and effective to operate. Approximately 12m 3 of the solid waste is now been treated directly as normal solid refuse. This paper describes the ANSTO clearance system, the contamination monitor tests and details practical problems associated with the direct monitoring of solid waste, including averaging of the activity in the package. The paper also briefly highlights the potential problem with the use of

  15. Impairment of paravascular clearance pathways in the aging brain.

    Science.gov (United States)

    Kress, Benjamin T; Iliff, Jeffrey J; Xia, Maosheng; Wang, Minghuan; Wei, Helen S; Zeppenfeld, Douglas; Xie, Lulu; Kang, Hongyi; Xu, Qiwu; Liew, Jason A; Plog, Benjamin A; Ding, Fengfei; Deane, Rashid; Nedergaard, Maiken

    2014-12-01

    In the brain, protein waste removal is partly performed by paravascular pathways that facilitate convective exchange of water and soluble contents between cerebrospinal fluid (CSF) and interstitial fluid (ISF). Several lines of evidence suggest that bulk flow drainage via the glymphatic system is driven by cerebrovascular pulsation, and is dependent on astroglial water channels that line paravascular CSF pathways. The objective of this study was to evaluate whether the efficiency of CSF-ISF exchange and interstitial solute clearance is impaired in the aging brain. CSF-ISF exchange was evaluated by in vivo and ex vivo fluorescence microscopy and interstitial solute clearance was evaluated by radiotracer clearance assays in young (2-3 months), middle-aged (10-12 months), and old (18-20 months) wild-type mice. The relationship between age-related changes in the expression of the astrocytic water channel aquaporin-4 (AQP4) and changes in glymphatic pathway function was evaluated by immunofluorescence. Advancing age was associated with a dramatic decline in the efficiency of exchange between the subarachnoid CSF and the brain parenchyma. Relative to the young, clearance of intraparenchymally injected amyloid-β was impaired by 40% in the old mice. A 27% reduction in the vessel wall pulsatility of intracortical arterioles and widespread loss of perivascular AQP4 polarization along the penetrating arteries accompanied the decline in CSF-ISF exchange. We propose that impaired glymphatic clearance contributes to cognitive decline among the elderly and may represent a novel therapeutic target for the treatment of neurodegenerative diseases associated with accumulation of misfolded protein aggregates. © 2014 American Neurological Association.

  16. Hepatic macrophage complement receptor clearance function following injury.

    Science.gov (United States)

    Cuddy, B G; Loegering, D J; Blumenstock, F A; Shah, D M

    1986-03-01

    Previous work has demonstrated that in vivo hepatic macrophage complement receptor clearance function is depressed following thermal injury. The present study was carried out to determine if complement receptor function depression is associated with other states of depressed host defense. Hepatic complement receptor clearance function was determined from the hepatic uptake of rat erythrocytes coated with antierythrocyte IgM (EIgM) in rats. Receptor function was determined following cannulation of a carotid artery, laparotomy plus enterotomy, hemorrhagic shock, trauma, thermal injury, acute bacteremia, acute endotoxemia, and injection of erythrocyte stroma, gelatinized lipid emulsion, or colloidal carbon. Hepatic uptake of EIgM was depressed following each of these experimental interventions except arterial cannulation. This effect was shown not to be due to a decrease in hepatic blood flow or depletion of complement and was therefore due to a depression in hepatic macrophage complement receptor clearance function. Thus, impairment of hepatic macrophage complement receptor function is associated with several states of depressed host defense.

  17. Clearance potential of ITER vacuum vessel activated materials

    International Nuclear Information System (INIS)

    Cepraga, D.G.; Cambi, G.; Frisoni, M.

    2002-01-01

    To demonstrate fusion's environmental attractiveness over the entire life cycle, a waste analysis is mandatory. The clearance is recommended by IAEA for releasing activated solid materials from regulatory control and for waste management policy. The paper focuses on the approach used to support waste analyses for ITER Generic Site Safety Report. The Material Unconditional Clearance Index of all the materials/zones on the equatorial mid-plane of ITER machine have been evaluated, based on IAEA-TECDOC-855. The Bonami-Nitawl-XSDNRPM sequence of the Scale-4.4a code system (using Vitenea-J library) has been firstly used for radiation transport analyses. Then the Anita-2000 code package is used for the activation calculation. The paper presents also, as an example, an application of the clearance indexes estimation for the ITER vacuum vessel materials. The results of the Anita-2000 have been compared with those obtained using the Fispact-99 activation code. (author)

  18. Contrast media and glomerular filtration: dose dependence of clearance for three agents

    International Nuclear Information System (INIS)

    Baeck, S.E.K.; Krutzen, E.; Nilsson-Ehle, P.

    1988-01-01

    Determination of plasma clearance of contrast agents has been advocated as a means to assess glomerular filtration rate. To evaluate the feasibility of different agents for this purpose, we have compared, in healthy volunteers, the dose dependence of plasma clearance for three contrast media (iohexol, a nonionic agent, and iothalamate and metrizoate, which are ionic substances), with special emphasis on the lower dose range (2-20 mL corresponding to 0.9-12.9 g, depending on dose and agent). Iohexol and iothalamate were cleared at constant rates, irrespective of given dose, whereas metrizoate clearance increased significantly at lower doses. In general, the clearances or iothalamate and metrizoate were, respectively, moderately and markedly higher than that of iohexol. The clearance of different doses of metrizoate (2 mL versus a radiographic dose of 40 mL or more) was also compared with the clearance of [ 51 Cr]EDTA in two groups of patients with reduced renal function. When compared with [ 51 Cr]EDTA in patients with renal dysfunction, metrizoate was cleared significantly faster after a 2-mL dose, whereas clearances were identical when the metrizoate dose was 40 mL or more. These findings indicate that tubular secretion plays an active role in the elimination of metrizoate. The pharmacokinetic properties of iohexol, in combination with its low toxicity, make it a suitable agent for determination of glomerular filtration rate in clinical practice

  19. Clearance from the anterior chamber of RBCs from human diabetics

    International Nuclear Information System (INIS)

    Williams, G.A.; Hatchell, D.L.; Collier, B.D.; Knobel, J.

    1984-01-01

    Erythrocytes from diabetic patients manifest decreased deformability and increased adherence. These abnormal membrane properties may diminish the ability of erythrocytes (RBCs) from diabetics to undergo deformation in passage through the trabecular meshwork. Using sodium chromate Cr 51-labeled RBCs from type I diabetic patients with proliferative retinopathy and normal control subjects, we studied RBC clearance from the rabbit anterior chamber. The mean time for 50% clearance (T50) of RBCs from diabetics (76 hours) was significantly longer than that for RBCs from normal subjects (19.5 hours). In this model, RBCs from diabetics have a slower clearance from the anterior chamber than do RBCs from normal subjects

  20. Experimental Study of Unshrouded Impeller Pump Stage Sensitivity to Tip Clearance

    Science.gov (United States)

    Williams, Robert W.; Zoladz, Thomas; Storey, Anne K.; Skelley, Stephen E.

    2002-01-01

    This viewgraph presentation provides information on an experiment. Its objective is to experimentally determine unshrouded impeller performance sensitivity to tip clearance. The experiment included: Determining impeller efficiency at scaled operating conditions in water at MSFC's Pump Test Equipment (PTE) Facility; Testing unshrouded impeller at three different tip clearances; Testing each tip clearance configuration at on- and off-design conditions, and collecting unsteady- and steady-state data in each configuration; Determining impeller efficiency directly using drive line torquemeter and pump inlet and exit total pressure measurements.

  1. Scan Manifestations and Blood Clearance Rates in Typhoid Liver

    International Nuclear Information System (INIS)

    Bahk, Yong Whee; Ahn, Jae Sung; Kim, Soon Hi

    1970-01-01

    Fourteen patients with typhoid fever studied by scanning and clearance-rate measurements of subcritical dose colloidal radiogold ( 198 Au). Mild to moderate enlargement of the liver and spleen was noted in 78.6 and 64.3 percent of patients, respectively; and splenic and spinal bone-marrow uptake was seen in 78.6 and 57.1 percent of cases, respectively. Typically, these scan changes occurred concomitantly (57.1%) and are considered to represent increased phagocytic activity of the RE cells which is characteristic of typhoid fever. The half clearance-time was significantly shortened during the first 10-day period of the illness indicating an increase in the hepatic blood in the early phase of typhoid infection. Hepatomegaly, splenomegaly and extrahepatic uptakes along with an accelerated (or less a normal) clearance time are characteristic of typhoid fever.

  2. Exaggerated natriuresis and lithium clearance in spontaneously hypertensive rats

    DEFF Research Database (Denmark)

    Holstein-Rathlou, N H; Kanters, J K; Leyssac, P P

    1988-01-01

    Since hypertension is associated with changes in the handling of various cations (including sodium and lithium) across the cell membrane, the present study investigated the validity of the lithium clearance method in hypertension by comparing two measures of proximal reabsorption. Thus, fractional...... lithium excretion and transit time (TT)-occlusion time (OT; e-TT/T) were determined successively in the same spontaneously hypertensive rat (SHR, Okamoto strain). The rats were examined both before and after an acute saline load. The results show that the lithium clearance method can be used...... for the determination of proximal reabsorption in SHR. Utilizing the lithium clearance method, the changes in renal sodium handling underlying the exaggerated natriuresis were investigated in unanaesthetized catheterized rats. It was found that the exaggerated natriuresis was associated with an increased output from...

  3. Kinematics Simulation Analysis of Packaging Robot with Joint Clearance

    Science.gov (United States)

    Zhang, Y. W.; Meng, W. J.; Wang, L. Q.; Cui, G. H.

    2018-03-01

    Considering the influence of joint clearance on the motion error, repeated positioning accuracy and overall position of the machine, this paper presents simulation analysis of a packaging robot — 2 degrees of freedom(DOF) planar parallel robot based on the characteristics of high precision and fast speed of packaging equipment. The motion constraint equation of the mechanism is established, and the analysis and simulation of the motion error are carried out in the case of turning the revolute clearance. The simulation results show that the size of the joint clearance will affect the movement accuracy and packaging efficiency of the packaging robot. The analysis provides a reference point of view for the packaging equipment design and selection criteria and has a great significance on the packaging industry automation.

  4. Numerical study on tip clearance effect on performance of a centrifugal compressor

    International Nuclear Information System (INIS)

    Eum, Hark Jin; Kang, Shin Kyoung

    2003-01-01

    Effect of tip leakage flow on through flow and performance of a centrifugal compressor impeller was numerically studied using CFX-TASCflow. Seven different tip clearances were used to consider the influence of tip clearance on performance. Secondary flow and loss factor were evaluated to understand the loss mechanism inside the impeller due to tip leakage flow. The calculated results were circumferentially averaged along the passage and at the impeller exit for quantitative discussion. Tip clearance effect on performance could be decomposed into inviscid and viscous components using one dimensional equation. The inviscid component is related with the specific work reduction and the viscous component is related with the additional entropy generation. Two components affected performance equally, while efficiency drop was mainly influenced by viscous loss. Performance and efficiency drop due to tip clearance were proportional to the ratio of tip clearance to exit blade height. A simple model suggested in the present study predict performance and efficiency drop quite successfully

  5. 32 CFR 155.4 - Policy.

    Science.gov (United States)

    2010-07-01

    ... Department of Defense OFFICE OF THE SECRETARY OF DEFENSE SECURITY DEFENSE INDUSTRIAL PERSONNEL SECURITY... security clearance for the applicant. (c) Except as otherwise provided for by E.O. 10865, as amended, or... commenced; (2) A clearance decision has been issued; or (3) The applicant's security clearance was suspended...

  6. Plasma Creatinine Clearance in the Dog

    Science.gov (United States)

    Frazier, Loy W.

    1977-01-01

    Lists materials and methods for an experiment that demonstrates the concept of glomerular filtration rate (GFR) using anesthesized dogs. In the dog, GFR is equivalent to the renal plasma clearance of exogenous creatinine. (CS)

  7. Renal clearance of /sup 99m/Tc-methylene-diphosphonate in human beings

    Energy Technology Data Exchange (ETDEWEB)

    Vattimo, A.

    1987-12-01

    The renal clearance of /sup 99m/Tc-MDP was measured in 13 patients who had bone scans and compared with the renal clearance of /sup 51/Cr-EDTA. No difference was found between the renal clearance of the two tracers, showing a close correlation (r = 0.98). These data suggest that the /sup 99m/Tc-MDP is excreted by the kidneys by glomerular filtration without tubular secretion.

  8. Frequency and factors effecting non clearance of lower pole renal stones

    International Nuclear Information System (INIS)

    Ullah, A.; Zubair, M.; Khan, N.; Malik, A.

    2015-01-01

    Renal stone disease is a major health hazard in Pakistan and extra-corporeal shockwave lithotripsy is one of comprehensive method used to treat these stones. The aim of this study is to determine the frequency of factors affecting the non-clearance of stone fragments of lower pole renal stone after extra corporeal shockwave lithotripsy. The study was done with the objective to determine the frequency the spatial anatomical factors which can influence the non-clearance of lower pole stone fragments after ESWL. Methods: One and nineteen (119) patients with lower pole renal stone less than 10 mm were subjected to maximum 3 sessions of extracorporeal shock wave lithotripsy. KUB radiographs, ultrasonography and intravenous urography were used as investigative tools for lower pole renal calyceal anatomy. X ray KUB and ultrasound were done after a week for clearance. Data was analysed with the help of SPSS version 10.0 and presented in the forms of tables and graphs. Results: There were 77 (64.71%) males and 42 (35.29%) females. Infundibulo-pelvic angle (IPA)>40 degree was present in 93 (78.15%), Infundibular length (IL) <22 mm in 107 (89.92%) and Infundibular width (IW) >4 mm was present in 100 (84.03%) patients. The frequency of stone non clearance was noted in 31 (26.05%). Infundibulo-pelvic angle (IPA)>40 degree (p=0.000), Infundibular length (IL)<22 mm (p=0.001) and Infundibular width (IW)>4 mm (p=0.046) were significant variables affecting stone clearance. Conclusion: The frequency of non-clearance of lower calyx of kidney stone is 26.05%. The clearance of fragments of the lower calyx kidney stones is affected by three spatial anatomical factors, i.e., Infundibulopelvic angle, Infundibular width and infundibular length. (author)

  9. Delayed clearance of serum HBsAg in compensated cirrhosis B

    DEFF Research Database (Denmark)

    Fattovich, G; Giustina, G; Sanchez-Tapias, J

    1998-01-01

    The aim of this study was to evaluate the incidence, prognostic factors and clinical significance of delayed clearance of serum HBsAg in compensated cirrhosis B.......The aim of this study was to evaluate the incidence, prognostic factors and clinical significance of delayed clearance of serum HBsAg in compensated cirrhosis B....

  10. Turbulent Heat Transfer of a Finned Plate in a Duct as Tip Clearance Changes

    Energy Technology Data Exchange (ETDEWEB)

    Park, Hae-Kyun; Chung, Bum-Jin [Kyung Hee University, Yongin (Korea, Republic of)

    2015-05-15

    Fins are employed to enhance the cooling performance of a system. There are a number of studies relevant to geometry of fins. Meanwhile, the studies relevant to tip clearance, have not performed enough, which is the distance between the tips of the fins and the wall. We investigated the optimal tip clearance, which maximizes the heat transfers by experimental and numerical analyses with wider range of Re{sub Dh} than the previous studies. Turbulent heat transfers of a finned plate were measured. For an extended range of tip clearance and Re{sub Dh} than other studies. A joint experimental and numerical analyses was performed to measure heat transfers. Mass transfer experiments using electroplating system was used and FLUENT 6.3.26 was used for the calculation. For the narrow tip clearances below 5 mm, were investigated by numerical method only. The bypass flow to the tip clearance region contributes to heat transfer area at the tip clearance region and does not contributes that of the fin region. Thus, the optimal tip clearance was founded and it exists vicinity of 0.2 mm.

  11. Novel sensors to enable closed-loop active clearance control in gas turbine engines

    Science.gov (United States)

    Geisheimer, Jonathan; Holst, Tom

    2014-06-01

    Active clearance control within the turbine section of gas turbine engines presents and opportunity within aerospace and industrial applications to improve operating efficiencies and the life of downstream components. Open loop clearance control is currently employed during the development of all new large core aerospace engines; however, the ability to measure the gap between the blades and the case and close down the clearance further presents as opportunity to gain even greater efficiencies. The turbine area is one of the harshest environments for long term placement of a sensor in addition to the extreme accuracy requirements required to enable closed loop clearance control. This paper gives an overview of the challenges of clearance measurements within the turbine as well as discusses the latest developments of a microwave sensor designed for this application.

  12. Does sleep disturbance affect the amyloid clearance mechanisms in Alzheimer's disease?

    Science.gov (United States)

    Yulug, Burak; Hanoglu, Lutfu; Kilic, Ertugrul

    2017-10-01

    Sleep is an important factor that plays a key role in Alzheimer's disease pathogenesis. However, it is still unclear whether poor-quality sleep may overlap with sleep disturbances in the underlying dysfunctional mechanisms of amyloid beta (Aβ) clearance metabolism. Here, we aimed to evaluate the current evidence on the role of sleep deprivation in Aβ clearance metabolism. To that end, we discuss possible mechanisms underlying the bidirectional interaction between the sleep deprivation and Aβ clearance pathways. © 2017 The Authors. Psychiatry and Clinical Neurosciences © 2017 Japanese Society of Psychiatry and Neurology.

  13. 76 FR 59379 - Proposed Information Collection; Comment Request; Generic Clearance for Research in Development...

    Science.gov (United States)

    2011-09-26

    ...-XXXX. Type of Review: Generic Clearance Request. Title: Generic Clearance for Research in Development... information collected through qualitative evaluation methods will inform the disclosure form's design and... Proposed Information Collection; Comment Request; Generic Clearance for Research in Development of...

  14. A comparison of analytic procedures for measurement of fractional dextran clearances

    NARCIS (Netherlands)

    Hemmelder, MH; de Jong, PE; de Zeeuw, D

    Fractional dextran clearances have been extensively used to study glomerular size selectivity. We report on an analysis of different laboratory procedures involved in measuring fractional dextran clearances. The deproteinization of plasma samples by 20% trichloroacetic acid (TCA) revealed a protein

  15. Spontaneous Clearance of Hepatitis C after Liver and Renal Transplantation

    Directory of Open Access Journals (Sweden)

    CH Dale

    2009-01-01

    Full Text Available Spontaneous clearance of hepatitis C virus (HCV is rare in immunocompromised patients, such as those who have undergone organ transplantation. It has been recognized that patients receiving liver transplantation for HCV-related disease have decreased graft and patient survival compared with those transplanted for other etiologies. There is a growing trend toward treating HCV recurrence aggressively after liver transplantation. For other organ transplant recipients with concurrent HCV, treatment is not often an option, given the high rates of graft rejection and loss secondary to interferon and its immunomodulatory effects. Although spontaneous clearance of HCV has been reported in recipients of solitary liver and renal transplants, a common factor arising in these cases has been previous exposure to interferon. To date, no reports of spontaneous clearance of HCV RNA have been reported in a multiorgan transplant recipient. A case of spontaneous clearance of HCV RNA in an immunocompromised patient, within five months of simultaneous liver and kidney retransplantation is described. Importantly, this patient had no previous exposure to interferon.

  16. Derivation methods for clearance levels applied to reactors

    International Nuclear Information System (INIS)

    Okoshi, Minoru; Seki, Takeo

    2001-01-01

    In order to support the discussion by the Nuclear Safety Commission, JAERI derived the unconditional clearance levels for concrete and metal arising from the operation and dismantling of nuclear reactors. The clearance levels of 20 radionuclides were derived from 10 μSv/y of individual doses by deterministic approach. In this approach, calculation models were established to assess individual doses resulting from 73 exposure pathways related to disposal and recycle/reuse, and realistic parameter values were selected considering Japanese natural and social conditions. The appropriateness of selected parameter values was confirmed by stochastic analyses. (author)

  17. The influence of body posture on lithium clearance

    DEFF Research Database (Denmark)

    Kamper, A L; Strandgaard, S; Holstein-Rathlou, N H

    1988-01-01

    measured four times at 1-week intervals: two in the supine and one in the sitting position, and one when the subject was walking around. Glomerular filtration rate was not influenced by posture changes. On the contrary, lithium clearance, which in the supine position was 30 +/- 9 ml/min (1 SD), tended...... during moderate physical activity. Hence, when renal tubular function is studied with the lithium clearance method, standardization of posture and physical activity is important. In such studies physical activity such as walking should particularly be avoided....

  18. Scan Manifestations and Blood Clearance Rates in Typhoid Liver

    Energy Technology Data Exchange (ETDEWEB)

    Bahk, Yong Whee; Ahn, Jae Sung; Kim, Soon Hi [St. Mary' s Hospital, Catholic Medical College, Seoul (Korea, Republic of)

    1970-09-15

    Fourteen patients with typhoid fever studied by scanning and clearance-rate measurements of subcritical dose colloidal radiogold ({sup 198}Au). Mild to moderate enlargement of the liver and spleen was noted in 78.6 and 64.3 percent of patients, respectively; and splenic and spinal bone-marrow uptake was seen in 78.6 and 57.1 percent of cases, respectively. Typically, these scan changes occurred concomitantly (57.1%) and are considered to represent increased phagocytic activity of the RE cells which is characteristic of typhoid fever. The half clearance-time was significantly shortened during the first 10-day period of the illness indicating an increase in the hepatic blood in the early phase of typhoid infection. Hepatomegaly, splenomegaly and extrahepatic uptakes along with an accelerated (or less a normal) clearance time are characteristic of typhoid fever.

  19. Clearance of labelled creatinine

    International Nuclear Information System (INIS)

    Eberstadt, P.; Liverant, J.

    1982-01-01

    Creatinine, extensively used in clinical work to evaluate glomerular filtration rate (G.F.R.) has caused controversy. Using simultaneously on dogs a gamma emitting agent measuring G.F.R., creatinine clearance proved to be higher. Aided by quantitative determinations and compartmental analysis fortunately the respective dilution spaces can be calculated. In the majority of these animals creatinine spaces are larger but in some equal to the ones of inulin

  20. Relationship of end-expiratory pressure, lung volume, and /sup 99m/Tc-DTPA clearance

    International Nuclear Information System (INIS)

    Cooper, J.A.; van der Zee, H.; Line, B.R.; Malik, A.B.

    1987-01-01

    We investigated the dose-response effect of positive end-expiratory pressure (PEEP) and increased lung volume on the pulmonary clearance rate of aerosolized technetium-99m-labeled diethylenetriaminepentaacetic acid (99mTc-DTPA). Clearance of lung radioactivity was expressed as percent decrease per minute. Base-line clearance was measured while anesthetized sheep (n = 20) were ventilated with 0 cmH 2 O end-expiratory pressure. Clearance was remeasured during ventilation at 2.5, 5, 10, 15, or 20 cmH 2 O PEEP. Further studies showed stepwise increases in functional residual capacity (FRC) (P less than 0.05) measured at 0, 2.5, 5, 10, 15, and 20 cmH 2 O PEEP. At 2.5 cmH 2 O PEEP, the clearance rate was not different from that at base line (P less than 0.05), although FRC was increased from base line. Clearance rate increased progressively with increasing PEEP at 5, 10, and 15 cmH 2 O (P less than 0.05). Between 15 and 20 cmH 2 O PEEP, clearance rate was again unchanged, despite an increase in FRC. The pulmonary clearance of aerosolized /sup 99m/Tc-DTPA shows a sigmoidal response to increasing FRC and PEEP, having both threshold and maximal effects. This relationship is most consistent with the hypothesis that alveolar epithelial permeability is increased by lung inflation

  1. Foot clearance and variability in mono- and multifocal intraocular lens users during stair navigation.

    Science.gov (United States)

    Renz, Erik; Hackney, Madeleine; Hall, Courtney

    2016-01-01

    Intraocular lenses (IOLs) provide distance and near refraction and are becoming the standard for cataract surgery. Multifocal glasses increase variability of toe clearance in older adults navigating stairs and increase fall risk; however, little is known about the biomechanics of stair navigation in individuals with multifocal IOLs. This study compared clearance while ascending and descending stairs in individuals with monofocal versus multifocal IOLs. Eight participants with multifocal IOLs (4 men, 4 women; mean age = 66.5 yr, standard deviation [SD] = 6.26) and fifteen male participants with monofocal IOLs (mean age = 69.9 yr, SD = 6.9) underwent vision and mobility testing. Motion analysis recorded kinematic and custom software-calculated clearances in three-dimensional space. No significant differences were found between groups on minimum clearance or variability. Clearance differed for ascending versus descending stairs: the first step onto the stair had the greatest toe clearance during ascent, whereas the final step to the floor had the greatest heel clearance during descent. This preliminary study indicates that multifocal IOLs have similar biomechanic characteristics to monofocal IOLs. Given that step characteristics are related to fall risk, we can tentatively speculate that multifocal IOLs may carry no additional fall risk.

  2. Low serum hyaluronic acid levels associated with spontaneous HBsAg clearance

    NARCIS (Netherlands)

    Harkisoen, S.; Arends, J. E.; van den Hoek, A.; van Erpecum, K. J.; Boland, G. J.; Hoepelman, A. I. M.

    2015-01-01

    Purpose The pathophysiological underlying mechanism of spontaneous HBsAg clearance in hepatitis B virus (HBV) infected patients is largely unknown. However, serum hyaluronic acid (sHA) plays a role in liver fibrosis progression and reversely could serve as a potential biomarker for HBsAg clearance.

  3. A pre- and postoperative study of split isotope clearance in childhood

    International Nuclear Information System (INIS)

    Faerber, D.; Czempiel, H.; Muehle, P.; Schick, F.; Wenzl, H.; Technische Univ. Muenchen; Technische Univ. Muenchen

    1979-01-01

    In 1978 43 patients have been operated in the Department of Pediatric Surgery, Krankenhaus Muenchen-Schwabing, because of recurrent urinary-tract infections with ureterovesical reflux or obstructive urinary-tract diseases. In all patients a split whole body clearance-study with a method modified after the method of Muehle with 131 J-Hippuran was carried out pre- or postoperatively, respectively. In 78,5% of these cases the clearance-results were corresponding to the results of X-ray examination; 6 of the remaining patients had a worse clearance result and 3 had a better result than the X-ray findings would have suggested. (orig.) [de

  4. Scan Manifestation and Trace-Dose Radiogold Clearance Rates in Obstructive Jaundice

    International Nuclear Information System (INIS)

    Kim, Dong Jip; Bahk, Yong Whee; Shinn, Kyung Sub

    1969-01-01

    The present study has been undertaken to analyze scan manifestation in obstructive jaundice. Scan changes were correlated with the duration of jaundice. In addition, clearance rates of trace dose of colloidal radiogold were assessed in each case. The materials were consisted of 19 cases with surgically and/or histopathologically verified obstructive jaundice from various causes including common duct stone, empyema of the gall bladder and carcinoma of the pancreas head etc. Blood clearance rates of colloidal 198 Au were determined after the injection of 8 uCi by simple geometrical drawing of recorded strip charts. Scan was performed following additional injection of the sam radiogold. In 16 out of 19 cases, the scan rather typical 'arborifrom' mottlings around the porta hepatis. The intensity and appearance of such mottlings on the scan was related with the duration of jaundice and level of serum bilirubin and alkaline phosphatase. The blood clearance rates remained to be within normal range in 74 percent of the patients. In the remaining 26 percent, clearance rate ranged between 4.1 and 6 minutes. It is concluded that the association of 'arboriform' mottlings and normal or mildly delayed clearance rates in the patients with jaundice is characteristic of obstructive change in the biliary system.

  5. Scan Manifestation and Trace-Dose Radiogold Clearance Rates in Obstructive Jaundice

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Dong Jip; Bahk, Yong Whee; Shinn, Kyung Sub [Catholic University College of Medicine, Seoul (Korea, Republic of)

    1969-09-15

    The present study has been undertaken to analyze scan manifestation in obstructive jaundice. Scan changes were correlated with the duration of jaundice. In addition, clearance rates of trace dose of colloidal radiogold were assessed in each case. The materials were consisted of 19 cases with surgically and/or histopathologically verified obstructive jaundice from various causes including common duct stone, empyema of the gall bladder and carcinoma of the pancreas head etc. Blood clearance rates of colloidal {sup 198}Au were determined after the injection of 8 uCi by simple geometrical drawing of recorded strip charts. Scan was performed following additional injection of the sam radiogold. In 16 out of 19 cases, the scan rather typical 'arborifrom' mottlings around the porta hepatis. The intensity and appearance of such mottlings on the scan was related with the duration of jaundice and level of serum bilirubin and alkaline phosphatase. The blood clearance rates remained to be within normal range in 74 percent of the patients. In the remaining 26 percent, clearance rate ranged between 4.1 and 6 minutes. It is concluded that the association of 'arboriform' mottlings and normal or mildly delayed clearance rates in the patients with jaundice is characteristic of obstructive change in the biliary system.

  6. 20 CFR 653.501 - Requirements for accepting and processing clearance orders.

    Science.gov (United States)

    2010-04-01

    ... the job order. (i) No agricultural or food processing order shall be included in job bank listings... clearance any job order seeking workers to perform agricultural or food processing work before reviewing it... order seeking workers to perform agricultural or food processing work into intrastate clearance unless...

  7. Clearance of insoluble dust from the lower respiratory tract

    Energy Technology Data Exchange (ETDEWEB)

    Morrow, P E; Gibb, F R; Johnson, L

    1964-01-01

    Clearance of tagged heavy metal aerosols (Fe, Hg, Mn, Ba, and U) in female beagles by in vivo counting was assessed. Fecal excretion paralleled lower respiratory tract clearance of Fe. No Fe was found in blood, indicating its biological insolubility. Ultrafiltration tests (an indication of biological solubility) ranked the heavy metals as: Hg, Mn, Fe, and U in order of decreasing solubility. The solubility ratios were remarkably similar to the ratios of inverse biological half-times.

  8. Secure real-time wireless video streaming in the aeronautical telecommunications network

    Science.gov (United States)

    Czernik, Pawel; Olszyna, Jakub

    2010-09-01

    As Air Traffic Control Systems move from a voice only environment to one in which clearances are issued via data link, there is a risk that an unauthorized entity may attempt to masquerade as either the pilot or controller. In order to protect against this and related attacks, air-ground communications must be secured. The challenge is to add security in an environment in which bandwidth is limited. The Aeronautical Telecommunications Network (ATN) is an enabling digital network communications technology that addresses capacity and efficiency issues associated with current aeronautical voice communication systems. Equally important, the ATN facilitates migration to free flight, where direct computer-to-computer communication will automate air traffic management, minimize controller and pilot workload, and improve overall aircraft routing efficiency. Protecting ATN communications is critical since safety-of-flight is seriously affected if an unauthorized entity, a hacker for example, is able to penetrate an otherwise reliable communications system and accidentally or maliciously introduce erroneous information that jeopardizes the overall safety and integrity of a given airspace. However, an ATN security implementation must address the challenges associated with aircraft mobility, limited bandwidth communication channels, and uninterrupted operation across organizational and geopolitical boundaries. This paper provides a brief overview of the ATN, the ATN security concept, and begins a basic introduction to the relevant security concepts of security threats, security services and security mechanisms. Security mechanisms are further examined by presenting the fundamental building blocks of symmetric encipherment, asymmetric encipherment, and hash functions. The second part of this paper presents the project of cryptographiclly secure wireless communication between Unmanned Aerial Vehicles (UAV) and the ground station in the ATM system, based on the ARM9 processor

  9. Dependence of 'CT clearance' on dosage and time

    International Nuclear Information System (INIS)

    Kaltenborn, H.A.; Klose, K.J.; Dexheimer, C.; Steinijans, V.

    1989-01-01

    The contrast medium dose used in CT renal function analysis corresponds to about 1 ml/kg body weight at a measurement interval of 5 or 10 minutes. In the present study the dependence of 'CT clearance' on dosage and time was examined in 12 healthy subjects. The amount of clearance was directly proportional to the employed contrast medium dose and to the length of the measurement interval. On account of the superior signal-to-noise ratio, the higher dose (1 ml/kg body weight) will continue to be prefered in future. The measurement interval can be limited to 10 minutes. (orig.) [de

  10. Pulmonary epithelial clearance of 99mTc-DTPA after thrombin-induced pulmonary microembolism

    International Nuclear Information System (INIS)

    Cooper, J.A.; Feustel, P.J.; Line, B.R.; Malik, A.B.

    1986-01-01

    We investigated the effect of thrombin-induced pulmonary microembolism on the pulmonary clearance rate of aerosolized 99mTc diethylenetriamine pentaacetic acid (99mTc-DTPA) in awake, chronically prepared sheep. Chest activity was recorded after administration of a 0.44 micron aerosol of 99mTc-DTPA. Decay-corrected data were fit to an exponential and expressed as percent decrease per min (%/min). Sheep were given alpha-thrombin intravenously (80 U/kg for 10 min) 60 min after the aerosol administration. The clearance rate prior to alpha-thrombin was 0.35 +/- 0.05 %/min (mean +/- SEM). During alpha-thrombin administration, the clearance rate increased to 5.84 +/- 0.70 %/min (p less than 0.001 from baseline), but returned to 0.41 +/- 0.06 %/min within 30 min after the end of the thrombin infusion. The increased clearance rate during alpha-thrombin administration was not due to increased lung volume since alpha-thrombin did not change functional residual capacity. Moreover, the clearance rate was unchanged during gamma-thrombin administration, which does not induce coagulation, or during alpha-thrombin challenge in defibrinogenated animals. alpha-thrombin administration in neutrophil-depleted sheep caused a transient increase in DTPA clearance similar to that in control sheep, suggesting that the increase occurred independently of neutrophils. The results indicate that alpha-thrombin causes a large, transient increase in 99mTc-DTPA clearance, which may be the result of increased epithelial permeability. This response is dependent on the activation of intravascular coagulation

  11. Lactate clearance cut off for early mortality prediction in adult sepsis and septic shock patients

    Science.gov (United States)

    Sinto, R.; Widodo, D.; Pohan, H. T.

    2018-03-01

    Previous lactate clearance cut off for early mortality prediction in sepsis and septic shock patient was determined by consensus from small sample size-study. We investigated the best lactate clearance cut off and its ability to predict early mortality in sepsis and septic shock patients. This cohort study was conducted in Intensive Care Unit of CiptoMangunkusumo Hospital in 2013. Patients’ lactate clearance and eight other resuscitationendpoints were recorded, and theoutcome was observed during the first 120 hours. The clearance cut off was determined using receiver operating characteristic (ROC) analysis, and its ability was investigated with Cox’s proportional hazard regression analysis using other resuscitation endpoints as confounders. Total of 268 subjects was included, of whom 70 (26.11%) subjects died within the first 120 hours. The area under ROC of lactate clearance to predict early mortality was 0.78 (95% % confidence interval [CI] 0.71-0.84) with best cut off was <7.5% (sensitivity and specificity 88.99% and 81.4% respectively). Compared with group achieving lactate clearance target, group not achieving lactate clearance target had to increase early mortality risk (adjusted hazard ratio 13.42; 95%CI 7.19-25.07). In conclusion, the best lactate clearance cut off as anearly mortality predictor in sepsis and septic shock patients is 7.5%.

  12. Numerical Investigation of Pressure Fluctuation Characteristics in a Centrifugal Pump with Variable Axial Clearance

    Directory of Open Access Journals (Sweden)

    Lei Cao

    2016-01-01

    Full Text Available Clearance flows in the sidewall gaps of centrifugal pumps are unsteady as well as main flows in the volute casing and impeller, which may cause vibration and noise, and the corresponding pressure fluctuations are related to the axial clearance size. In this paper, unsteady numerical simulations were conducted to predict the unsteady flows within the entire flow passage of a centrifugal pump operating in the design condition. Pressure fluctuation characteristics in the volute casing, impeller, and sidewall gaps were investigated with three axial clearance sizes. Results show that an axial clearance variation affects the pressure fluctuation characteristics in each flow domain by different degree. The greatest pressure fluctuation occurs at the blade pressure surface and is almost not influenced by the axial clearance variation which has a certainly effect on the pressure fluctuation characteristics around the tongue. The maximum pressure fluctuation amplitude in the sidewall gaps is larger than that in the volute casing, and different spectrum characteristics show up in the three models due to the interaction between the clearance flow and the main flow as well as the rotor-stator interaction. Therefore, clearance flow should be taken into consideration in the hydraulic design of centrifugal pumps.

  13. Glomerular filtration in kidney recipients measured by plasma clearance of 169Yb-DTPA

    International Nuclear Information System (INIS)

    Stribrna, J.; Oppelt, A.; Jirickova, E.; Janata, V.; Kocandrle, V.; Sup, I.; Woller, P.; Franke, W.G.

    1986-01-01

    Values of 169 Yb-DTPA clearance (C DTPA ) calculated after a single injection were compared in 26 recipients of kidneys with renal clearance of inulin (C in ), polyfructosan S (C pf ) and creatinine (C cr ). In 21 patients the examinations were made simultaneously, in 5 patients C DTPA was measured within a short interval after the examination of renal clearance. The mean C DTPA values did not significantly differ from C cr but were significantly higher (p in and C pf (by 33% on average). Investigation of changes in C DTPA as compared with C in and C pf showed no significant difference in glomerular filtration (GF). This was measured using inulin and polyfructosan. The results showed that the differing molecular weight of inulin and polyfructosan S had no detectable effect on the GF of kidney recipients. The plasma clearance of 169 Yb-DTPA similarly to C cr overestimates the GF measured by inulin and polyfructosan clearance. (author)

  14. A computer program for unilateral renal clearance calculation by a modified Oberhausen method

    International Nuclear Information System (INIS)

    Brueggemann, G.

    1980-01-01

    A FORTAN program is presented which, on the basis of data obtained with NUKLEOPAN M, calculates the glomerular filtration rate with sup(99m)Tc-DTPA, the unilateral effective renal plasma flow with 131 I-hippuran, and the parameters for describing the isotope rephrogram (ING) with 131 I-hippuran. The results are calculated fully automatically upon entry of the data, and the results are processed and printed out. The theoretical fundamentals of ING and whole-body clearance calculation are presented as well as the methods available for unilateral clearance calculation, and the FORTAN program is described in detail. The standard values of the method are documented, as well as a comparative gamma camera study of 48 patients in order to determine the accuracy of unilateral imaging with the NUKLEOPAN M instrument, a comparison of unilateral clearances by the Oberhausen and Taplin methods, and a comparison between 7/17' plasma clearance and whole-body clearance. Problems and findings of the method are discussed. (orig./MG) [de

  15. Clearance, a powerful tool in optimizing the volume of radioactive wastes

    International Nuclear Information System (INIS)

    Blommaert, W.; Teunckens, L.

    1997-01-01

    In the framework its activities in decommissioning nuclear installations, Belgoprocess applies the clearance practice in optimizing the volume of radioactive wastes. The applied clearance methodology is discussed with special emphasis to different types of materials and to the associated measurements. Four practical cases are elaborated, dealing with the decommissioning and decontamination of two small buildings up to green field conditions, the unconditional release of large quantities of slightly contaminated active carbon, the melting and clearance of stainless steel fuel racks and of aluminium heat exchangers. The attention is drawn on practical problems associated with sampling and measurement strategies, in relation to the proposed low limits for unconditional release. (author)

  16. A review and comparison of international exemption and clearance levels

    International Nuclear Information System (INIS)

    Cooper, J.R.; Mobbs, S.F.

    1997-01-01

    The publication of new European Basic Safety Standards by the European Commission and of new International Basic Safety Standards by the IAEA together with other international agencies, has led to increased interest in the application of the concepts of exemption and clearance. This paper discusses the derivation of radionuclide-specific exemption and clearance values for application in various areas of the regulation of radioactive materials. (author)

  17. Clearance measurements on activated parts of accelerators by combined methods; Verfahrenskombinierte Freigabemessung aktivierter Beschleunigerteile

    Energy Technology Data Exchange (ETDEWEB)

    Jansen, S.; Friedemann, S. [VKTA, Dresden (Germany); Enghardt, W. [Technische Univ. Dresden (Germany). OncoRay

    2016-07-01

    The process of clearance of radioactive materials according to paragraph 29 StrlSchV contents the comparison of activity to mass and surface of the material. To avoid a borderless assessment of activity of activation it is often necessary to use combined measurement methods: For clearance of collimators of a medical proton accelerator (energy range up to 200 MeV) it needs to know the nuclide composition. The energetical and geometrical calibration was fixed by experiments. The clearance based on measurements of activity distribution, gammaspectroscopy verification of nuclide composition and gamma-counting detectors. Parts of medical electron-accelerators achieved its clearance by combination of abovementioned methods and in-situ-gammaspectroscopy. Activated und contaminated lead stones achieved its clearance by measurements of fluence, laboratory evaluation of samples, in-situ-gammaspectroscopy and wipe tests.

  18. Comparison of gas clearance and radioactive microspheres for pancreatic blood flow measurement

    International Nuclear Information System (INIS)

    DeMar, A.R.; Graham, L.S.; Lake, R.; Fink, A.S.

    1989-01-01

    Measurement of pancreatic blood flow (PBF) is technically demanding. Although radiolabeled microspheres are considered the gold standard for PBF assessment, they have practical limitations. In the current study, H 2 and xenon-133 gas clearance techniques were adapted to PBF measurement and compared to radiolabeled microsphere techniques. Simultaneous measurements of PBF were made using either hydrogen or xenon gas washout and radiolabeled microspheres. Measurements were made under basal, vasoconstricted (vasopressin 2U i.v. or nicotine 4 micrograms/kg/h) and stimulated (secretin 125 ng/kg/h or 2 U/kg i.v.) conditions (random order). Mean PBF was 26.9 +/- 5.3, 50.5 +/- 2.3 and 27.6 +/- 5.2 ml/min/100 g basally, 36.9 +/- 8.0, 90.1 +/- 18.9, and 81.7 +/- 14.5 ml/min/100 g in the stimulated state, and 24.2 +/- 7.8, 25.0 +/- 3.5, and 14.9 +/- 7.5 ml/min/100 g in the vasoconstricted state for hydrogen gas clearance, xenon gas clearance, and radiolabeled microspheres, respectively. The H 2 clearance technique resulted in tissue trauma, was complicated by frequent electrode displacement, and correlated poorly (r2 = 0.36, p greater than 0.05) with microsphere values. In contrast, xenon clearance measurement had no apparent effect on the pancreas and correlated well (r2 = 0.83, p less than 0.01) with microsphere data. We conclude that xenon clearance offers an attractive, validated alternative to radiolabeled microspheres for measuring pancreatic blood flow

  19. Long-term clearance from small airways in subjects with ciliary dysfunction

    Directory of Open Access Journals (Sweden)

    Hjelte Lena

    2006-05-01

    Full Text Available Abstract The objective of this study was to investigate if long-term clearance from small airways is dependent on normal ciliary function. Six young adults with primary ciliary dyskinesia (PCD inhaled 111 Indium labelled Teflon particles of 4.2 μm geometric and 6.2 μm aerodynamic diameter with an extremely slow inhalation flow, 0.05 L/s. The inhalation method deposits particles mainly in the small conducting airways. Lung retention was measured immediately after inhalation and at four occasions up to 21 days after inhalation. Results were compared with data from ten healthy controls. For additional comparison three of the PCD subjects also inhaled the test particles with normal inhalation flow, 0.5 L/s, providing a more central deposition. The lung retention at 24 h in % of lung deposition (Ret24 was higher (p 24 with slow inhalation flow was 73.9 ± 1.9 % compared to 68.9 ± 7.5 % with normal inhalation flow in the three PCD subjects exposed twice. During day 7–21 the three PCD subjects exposed twice cleared 9 % with normal flow, probably representing predominantly alveolar clearance, compared to 19 % with slow inhalation flow, probably representing mainly small airway clearance. This study shows that despite ciliary dysfunction, clearance continues in the small airways beyond 24 h. There are apparently additional clearance mechanisms present in the small airways.

  20. The role of the health physicist in nuclear security.

    Science.gov (United States)

    Waller, Edward J; van Maanen, Jim

    2015-04-01

    Health physics is a recognized safety function in the holistic context of the protection of workers, members of the public, and the environment against the hazardous effects of ionizing radiation, often generically designated as radiation protection. The role of the health physicist as protector dates back to the Manhattan Project. Nuclear security is the prevention and detection of, and response to, criminal or intentional unauthorized acts involving or directed at nuclear material, other radioactive material, associated facilities, or associated activities. Its importance has become more visible and pronounced in the post 9/11 environment, and it has a shared purpose with health physics in the context of protection of workers, members of the public, and the environment. However, the duties and responsibilities of the health physicist in the nuclear security domain are neither clearly defined nor recognized, while a fundamental understanding of nuclear phenomena in general, nuclear or other radioactive material specifically, and the potential hazards related to them is required for threat assessment, protection, and risk management. Furthermore, given the unique skills and attributes of professional health physicists, it is argued that the role of the health physicist should encompass all aspects of nuclear security, ranging from input in the development to implementation and execution of an efficient and effective nuclear security regime. As such, health physicists should transcend their current typical role as consultants in nuclear security issues and become fully integrated and recognized experts in the nuclear security domain and decision making process. Issues regarding the security clearances of health physics personnel and the possibility of insider threats must be addressed in the same manner as for other trusted individuals; however, the net gain from recognizing and integrating health physics expertise in all levels of a nuclear security regime far

  1. APPLICATION OF DSM IN OBSTACLE CLEARANCE SURVEYING OF AERODROME

    Directory of Open Access Journals (Sweden)

    X. Qiao

    2016-06-01

    Full Text Available Compared to the wide use of digital elevation model (DEM, digital surface model (DSM receives less attention because that it is composed by not only terrain surface, but also vegetations and man-made objects which are usually regarded as useless information. Nevertheless, these objects are useful for the identification of obstacles around an aerodrome. The primary objective of the study was to determine the applicability of DSM in obstacle clearance surveying of aerodrome. According to the requirements of obstacle clearance surveying at QT airport, aerial and satellite imagery were used to generate DSM, by means of photogrammetry, which was spatially analyzed with the hypothetical 3D obstacle limitation surfaces (OLS to identify the potential obstacles. Field surveying was then carried out to retrieve the accurate horizontal position and height of the obstacles. The results proved that the application of DSM could make considerable improvement in the efficiency of obstacle clearance surveying of aerodrome.

  2. Dysregulation of Nutrient Sensing and CLEARance in Presenilin Deficiency

    Directory of Open Access Journals (Sweden)

    Kavya Reddy

    2016-03-01

    Full Text Available Attenuated auto-lysosomal system has been associated with Alzheimer disease (AD, yet all underlying molecular mechanisms leading to this impairment are unknown. We show that the amino acid sensing of mechanistic target of rapamycin complex 1 (mTORC1 is dysregulated in cells deficient in presenilin, a protein associated with AD. In these cells, mTORC1 is constitutively tethered to lysosomal membranes, unresponsive to starvation, and inhibitory to TFEB-mediated clearance due to a reduction in Sestrin2 expression. Normalization of Sestrin2 levels through overexpression or elevation of nuclear calcium rescued mTORC1 tethering and initiated clearance. While CLEAR network attenuation in vivo results in buildup of amyloid, phospho-Tau, and neurodegeneration, presenilin-knockout fibroblasts and iPSC-derived AD human neurons fail to effectively initiate autophagy. These results propose an altered mechanism for nutrient sensing in presenilin deficiency and underline an importance of clearance pathways in the onset of AD.

  3. Effects of sustained exercise on pulmonary clearance of aerosolized 99mTc-DTPA

    International Nuclear Information System (INIS)

    Lorino, A.M.; Meignan, M.; Bouissou, P.; Atlan, G.

    1989-01-01

    The effects of intensive prolonged exercise on the pulmonary clearance rate of aerosolized 99m Tc-labeled diethylenetriaminepentaacetate ( 99m Tc-DTPA) and pulmonary mechanics were studied in seven healthy nonsmoking volunteers. 99m Tc-DTPA clearance and pulmonary mechanics (lung volumes and compliance) were assessed before and after 75 min of constant-load exercise performed on a treadmill, corresponding to 75% of maximal O 2 uptake. Because both clearance measurements were made in similar conditions of pulmonary blood flow, respiratory rate, and tidal volume, changes in clearance rate can be assumed to represent changes of alveolar epithelial permeability. After exercise, total, apical, and basal clearance were significantly increased (P less than 0.01, 0.05, and 0.05, respectively) and the increases in total clearance and tidal volume observed during exercise were significantly correlated (P less than 0.05). In contrast, no significant change was found in pulmonary mechanics. These results show that prolonged intensive exercise induces an increase in epithelial permeability, which appears to be related to the mechanical effects of sustained increased ventilation. Because no change was evidenced in pulmonary volumes or in lung elasticity, our results suggest that this increase may result from alteration of the intercellular tight junctions rather than from a surfactant deficiency

  4. Higher Midazolam Clearance in Obese Adolescents Compared with Morbidly Obese Adults

    NARCIS (Netherlands)

    Rongen, van A.; Brill, M.J.E.; Vaughns, J.D.; Välitalo, P.A.J.; Dongen, van E.P.A.; Ramshorst, van B.; Barrett, J.S.; Anker, van den J.N.; Knibbe, C.A.J.

    2017-01-01

    The clearance of cytochrome P450 (CYP) 3A substrates is reported to be reduced with lower age, inflammation and obesity. As it is unknown what the overall influence is of these factors in the case of obese adolescents vs. morbidly obese adults, we studied covariates influencing the clearance of the

  5. Unauthorized Disclosure: Can Behavioral Indicators Help Predict Who Will Commit Unauthorized Disclosure of Classified National Security Information?

    Science.gov (United States)

    2015-06-01

    Katherine Herbig, Espionage by the Numbers: A Statistical Overview, accessed April 14, 2015, http://www.wright.edu/rsp/Security/Treason/Numbers.htm 5...submitted for top-secret clearances with “derogatory financial information.”43 The debt amount reviewed was $500 in delinquency for at least 120 days, which...Investigative Service’s (DIS) “ delinquent debt criteria with amount of delinquent debt” and Defense Central Index of Investigation’s (DCII) final

  6. 76 FR 20722 - In the Matter of Indiana Michigan Power Company; DC Cook Nuclear Plant Independent Spent Fuel...

    Science.gov (United States)

    2011-04-13

    .... Government-granted security clearance (i.e., Top Secret, Secret, or Confidential). d. A review of the... active U.S. Government granted security clearance, i.e., Top Secret, Secret or Confidential. 5. The... another active U.S. Government granted security clearance, i.e., Top Secret, Secret or Confidential. 6...

  7. 75 FR 24998 - In the Matter of Florida Power and Light Company: Turkey Point Nuclear Plant; Independent Spent...

    Science.gov (United States)

    2010-05-06

    .... Government-granted security clearance (i.e., Top Secret, Secret, or Confidential). d. A review of the... active U.S. Government granted security clearance, i.e., Top Secret, Secret or Confidential. 5. The... another active U.S. Government granted security clearance, i.e., Top Secret, Secret or Confidential. 6...

  8. Axial compressor blade design for desensitization of aerodynamic performance and stability to tip clearance

    Science.gov (United States)

    Erler, Engin

    Tip clearance flow is the flow through the clearance between the rotor blade tip and the shroud of a turbomachine, such as compressors and turbines. This flow is driven by the pressure difference across the blade (aerodynamic loading) in the tip region and is a major source of loss in performance and aerodynamic stability in axial compressors of modern aircraft engines. An increase in tip clearance, either temporary due to differential radial expansion between the blade and the shroud during transient operation or permanent due to engine wear or manufacturing tolerances on small blades, increases tip clearance flow and results in higher fuel consumption and higher risk of engine surge. A compressor design that can reduce the sensitivity of its performance and aerodynamic stability to tip clearance increase would have a major impact on short and long-term engine performance and operating envelope. While much research has been carried out on improving nominal compressor performance, little had been done on desensitization to tip clearance increase beyond isolated observations that certain blade designs such as forward chordwise sweep, seem to be less sensitive to tip clearance size increase. The current project aims to identify through a computational study the flow features and associated mechanisms that reduces sensitivity of axial compressor rotors to tip clearance size and propose blade design strategies that can exploit these results. The methodology starts with the design of a reference conventional axial compressor rotor followed by a parametric study with variations of this reference design through modification of the camber line and of the stacking line of blade profiles along the span. It is noted that a simple desensitization method would be to reduce the aerodynamic loading of the blade tip which would reduce the tip clearance flow and its proportional contribution to performance loss. However, with the larger part of the work on the flow done in this

  9. Characterization and Clearance of m/s Sigyn

    International Nuclear Information System (INIS)

    Jiselmark, Jonatan; Vreede, Patrick

    2016-01-01

    M/s Sigyn was a 2044 ton ship that transported contaminated material between 1982 and 2013. Most of the transports were with spent nuclear fuel between Swedish nuclear power plants and the Swedish fuel repository, Clab. In addition to spent fuel, m/s Sigyn also transported big contaminated components, from nuclear power plants in Europe, to Studsvik for analysis or decontamination and melting. She also transported components from Swedish nuclear power plants to final disposal of short lived waste, SFR. Even though all transported items have been cleaned, checked and wrapped with plastics, some activity ended up as contamination onboard. In December 2013 it was decided that m/s Sigyn was subject for decommissioning due to her age. This Paper describes the method in which the activity onboard m/s Sigyn was characterized and clearance levels were calculated. This method for radiological characterization and clearance has recently been developed in Sweden, the method is efficient in that it does not need a big pre characterization survey. Only the nuclide distribution and history of the object, is needed to start the final survey. In the future there will be further development of the method, making it possible to reduce the number of measurements even more. This will further optimize the method and reduce the cost for final surveys and clearance. (authors)

  10. A stochastic approach to the derivation of exemption and clearance levels

    International Nuclear Information System (INIS)

    Deckert, A.

    1997-01-01

    Deciding what clearance levels are appropriate for a particular waste stream inherently involves a number of uncertainties. Some of these uncertainties can be quantified using stochastic modeling techniques, which can aid the process of decision making. In this presentation the German approach to dealing with the uncertainties involved in setting clearance levels is addressed. (author)

  11. Modelling of Outer and Inner Film Oil Pressure for Floating Ring Bearing Clearance in Turbochargers

    International Nuclear Information System (INIS)

    Zhang Hao; Shi Zhanqun; Gu Fengshou; Ball, Andrew

    2011-01-01

    Floating ring bearing is widely used in turbochargers to undertake the extreme condition of high rotating speed and high operating temperature. It is also the most concerned by the designers and users alike due to its high failure rate and high maintenance cost. Any little clearance change may result in oil leakage, which in turn cause blue smoke or black smoke according to leakage types. However, there is no condition monitoring of this bearing because it is almost impossible to measure the clearance especially the inner clearance, in which the inner oil film directly bears the high speed rotation. In stead of measuring clearance directly, this paper has proposed a method that uses film pressure as a measure to monitor the bearing clearance and its variation. A non-linear mathematical model is developed by using Reynolds equations with non-linear oil film pressure. A full description of the outer and inner film is provided along both axial and radial directions. A numerical simulation is immediately carried out. Variable clearance changes are investigated using the mathematical model. Results show the relationship between clearance and film pressure.

  12. Comparison between total and renal plasma clearance of [51Cr]EDTA

    International Nuclear Information System (INIS)

    Broechner-Mortensen, J.; Roedbro, P.

    1976-01-01

    The total plasma (E 1 ) and renal plasma (E 2 ) clearances of [ 51 Cr]EDTA were measured simultaneously in 40 patients with a wide range of renal function. The regression equation was E 1 = 0.997E 2 + 4.1; the slope of the regression line was not significantly different from 1.00, and the intercept differed significantly from zero. The results suggest that [ 51 Cr]EDTA has a significant extrarenal clearance of approximately 4 ml/min, independent of renal function. The data are used to correct the total [ 51 Cr]EDTA plasma clearance, measured by a simplified method, to yield a rapid, accurate and precise measurement of glomerular filtration rate for routine clinical use. (Auth.)

  13. Traffic Incident Clearance Time and Arrival Time Prediction Based on Hazard Models

    Directory of Open Access Journals (Sweden)

    Yang beibei Ji

    2014-01-01

    Full Text Available Accurate prediction of incident duration is not only important information of Traffic Incident Management System, but also an effective input for travel time prediction. In this paper, the hazard based prediction models are developed for both incident clearance time and arrival time. The data are obtained from the Queensland Department of Transport and Main Roads’ STREAMS Incident Management System (SIMS for one year ending in November 2010. The best fitting distributions are drawn for both clearance and arrival time for 3 types of incident: crash, stationary vehicle, and hazard. The results show that Gamma, Log-logistic, and Weibull are the best fit for crash, stationary vehicle, and hazard incident, respectively. The obvious impact factors are given for crash clearance time and arrival time. The quantitative influences for crash and hazard incident are presented for both clearance and arrival. The model accuracy is analyzed at the end.

  14. Production of plastic scintillation survey meter for clearance verification measurement

    International Nuclear Information System (INIS)

    Tachibana, Mitsuo; Shiraishi, Kunio; Ishigami, Tsutomu; Tomii, Hiroyuki

    2008-03-01

    In the Nuclear Science Research Institute, the decommissioning of various nuclear facilities is carried out according to the plan for meeting the midterm goal of the Japan Atomic Energy Agency (JAEA). An increase in the clearance verification measurement of concrete on buildings and the radiation measurement for releasing controlled areas will be expected along with the dismantlement of nuclear facilities in the future. The radiation measurement for releasing controlled areas has been carried out in small-scale nuclear facilities including the JPDR (Japan Power Demonstration Reactor). However, the radiation measurement with an existing measuring device was difficult in effects of radiation from radioactive materials that remains in buried piping. On the other hand, there is no experience that the clearance verification measurement is executed in the JAEA. The generation of a large amount of clearance object will be expected along with the decommissioning of the nuclear facilities in the future. The plastic scintillation survey meter (hereafter, 'PL measuring device') was produced to apply to the clearance verification measurement and the radiation measurement for releasing controlled areas. The basic characteristic test and the actual test were confirmed using the PL measuring device. As a result of these tests, it was found that the evaluation value of radioactivity with the PL measuring device was accuracy equal with the existing measuring device. The PL measuring device has feature of the existing measuring device with a light weight and easy operability. The PL measuring device can correct the gamma ray too. The PL measuring device is effective to the clearance verification measurement of concrete on buildings and the radiation measurement for releasing controlled areas. (author)

  15. [Airway clearance techniques in chronic obstructive pulmonary syndrome : 2011 update].

    Science.gov (United States)

    Opdekamp, C

    2011-09-01

    For many years the airway clearance techniques used in chest physical therapy were assimilated with the singular technique of postural drainage, percussions and vibrations. However the side effects and counter indications and the lack of scientific proof regarding this technique have forced reflection and development of other techniques more comfortable and without deleterious effects. If all these techniques show a high efficiency in terms of improved mucociliary clearance, the literature is unanimous on how little effect these techniques have in the short and the long-term with regards to lung function and arterial blood gases. In view of the scientific literature, it is clear that the airway clearance techniques don't have the same recognition concerning their efficiency in all obstructive pulmonary diseases. As the cornerstone in the management of cystic fibrosis, the efficiency of the bronchial hygiene techniques are in general poorly documented in the management of the non-cystic fibrosis bronchiectasis, bronchitis or emphysema. The use of the chest physical therapy seems more to do with the interpretation of the imagery and symptomatology. The airway clearance techniques should be individualised according to symptoms, the amount of expectorated mucus and the objectives signs of secretions retention or subjective signs of difficulty expectorating secretions with progression of the disease.

  16. Factors affecting lower calyceal stone clearance after Extracorporeal shock wave lithotripsy

    Directory of Open Access Journals (Sweden)

    S. Azab

    2013-03-01

    Conclusions: There is no statistically significant effect of stone size, anatomy of the lower calyx and BMI on stone clearance after ESWL of lower calyceal stones. However, small stone size (≤2 cm, a shorter and wider infundibulum and a larger lower-pole infundibulopelvic angle seem to promote a more rapid and more complete stone clearance.

  17. Chromium-51-EDTA clearance in adults with a single-plasma sample.

    Science.gov (United States)

    Mårtensson, J; Groth, S; Rehling, M; Gref, M

    1998-12-01

    In 1996, a committee on renal clearance recommended a mean sojourn time-based methodology for single-sample determination of plasma clearance of 99mTc-diethylenetriamine pentaacetic acid (DTPA) to be used on adults if the patient's glomerular filtration rate (GFR) is suspected to be >30 ml/min. The main purpose of this study was to derive a mean sojourn time-based formula for calculation of 51Cr-ethylenediamine tetraacetic acid (EDTA) clearance in adults. Two groups of patients with 51Cr-EDTA clearance (Cl) between 16 and 172 ml/min were studied. In Group I (n = 46), reference Cl was determined as a multiplasma sample, single-injection method (ClSM). Sixteen blood samples were drawn from 0 until 5 hr after a single intravenous injection of 51Cr-EDTA. In Group II (n = 1046), reference Cl was determined by the Brøchner-Mortensen four-sample clearance method (ClBM). The plasma time-activity curves of Group I were used to derive two mean sojourn time-based formulas (Formulas 1 and 2) for calculation of a single-sample clearance. Formula 1 was derived from the entire time-activity curve, whereas the derivation of Formula 2 used only the final slope of the time-activity curve. The accuracy of the two formulas and the Christensen and Groth 99mTc-DTPA formula was tested on Group II. Chromium-51-EDTA Cl calculated by Formula 1 was almost identical to the Cl calculated by the reference Cl method (r = 0.982; SDdiff = 5.82 ml/min). Both 51Cr-EDTA Cl calculated by Formula 2 and by the 99mTc-DTPA formula showed close correlation with the reference method (r = 0.976, r = 0.985, respectively) but systematically overestimated GFR for the whole range of clearance values by 3.5 and 3.2 ml/min (ptime methodology. The determination is marginally more accurate (ptime-activity curve than from only the final slope. The single-sample formula derived for determination of 99mTc-DTPA Cl tends slightly to overestimate GFR if used to calculate 51Cr-EDTA Cl.

  18. Clearance of material with negligible levels of radioactivity based on the amended German radiation protection ordinance

    International Nuclear Information System (INIS)

    Schaller, G.; Bayer, A.

    2002-01-01

    For the first time the modalities for the clearance of relevant materials have been laid down in the amended Radiation Protection Ordinance in a comprehensive form. A distinction is made between unconditional clearance and cases of clearance in which disposal, recycling, and re-use is prescribed. The focus of attention in the case of unconditional clearance consists in special consideration of large volumes of building rubble and excavated soil. Material can only be released from supervision under the Atomic Energy Act, when the radiation-related risk, and correspondingly, also the dose from material issued with clearance, are at negligible levels. In order to facilitate the practical application of clearance, values have been derived on the basis of scenarios which cover all radiation exposures which can reasonably be considered. (orig.) [de

  19. Transplacental clearance and blood flows of bovine gravid uterus at several stages of gestation

    International Nuclear Information System (INIS)

    Reynolds, L.P.; Ferrell, C.L.

    1987-01-01

    Rates of uterine and umbilical blood flows and transplacental clearance of deuterium oxide (D 2 O) were determined for cows on 137 +/- 1.0 (SE, n = 9), 180 +/- 0.5 (n = 8), 226 +/- 0.4 (n = 9), and 250 +/- 1.8 (n = 5) days of gestation. From days 137 to 250, rates increased 4.5-fold for uterine blood flow, 21-fold for umbilical blood flow, and 14-fold for clearance of D 2 O. Changes in rates of umbilical blood flow and D 2 O clearance paralleled increased rates of fetal growth and metabolism, which have previously been reported to occur during the last half of gestation. The regressions of D 2 O clearance on uterine and umbilical blood flows were significant (P less than 0.01) and explained 94-99% of the variation in placental clearance of D 2 O. Because the rate of D 2 O clearance was always less than that of uterine and umbilical blood flows, and because a relatively simple statistical model explained most of the variation in clearance, it was suggested that a concurrent or countercurrent arrangement of maternal and fetal placental microvasculatures is not adequate to explain clearance of highly diffusable substances across the bovine placenta. In addition, a placental exchange diagram of the data showed the existence of severe uneven distribution of maternal and fetal placental blood flows and/or significant shunting of maternal and fetal placental flows away from areas of exchange. Taken together, these data indicate that the placenta of the cow, like those of the sheep and goat, represents a relatively inefficient system of transplacental exchange

  20. Limitations of regional myocardial thallium clearance for identification of disease in individual coronary arteries

    International Nuclear Information System (INIS)

    Becker, L.C.; Rogers, W.J. Jr.; Links, J.M.; Corn, C.

    1989-01-01

    The purpose of this study was to critically evaluate the usefulness of postexercise regional myocardial thallium-201 clearance for identifying disease in individual coronary arteries. Exercise and redistribution planar imaging studies were performed in 114 subjects, including 19 normal volunteers and 95 patients undergoing cardiac catheterization (70 with and 25 without greater than or equal to 50% narrowing in one or more coronary arteries). Thallium clearance was measured from predefined myocardial regions corresponding to the left anterior descending, left circumflex and right coronary arteries and was expressed as the percent decrease in activity at 4 h, assuming monoexponential clearance. In regions perfused by a normal or insignificantly diseased coronary artery, mean 4 h clearance was 58.9 +/- 9.4% for normal volunteers, 43.1 +/- 15.5% for catheterized patients without coronary artery disease and 36.3 +/- 24.9% for catheterized patients with coronary artery disease (p less than 0.001 patients with coronary artery disease versus normal volunteers). Clearance from normal regions was significantly associated with two measures of exercise performance: percent of predicted maximal heart rate achieved (r = 0.49) and exercise duration (r = 0.35). In regions perfused by a stenotic coronary artery, mean clearance was lower (31.1 +/- 19.8%) but was not significantly different from that in normal regions in the same patients. Clearance from diseased regions was also associated with maximal exercise heart rate (r = 0.28) and exercise duration (r = 0.41), but not with percent coronary artery stenosis (r = 0.02). After taking exercise performance into account, the number of diseased vessels or the presence or absence of disease in a given vessel had little influence on regional thallium clearance

  1. Small solute clearance from the lungs of patients with cardiogenic and noncardiogenic pulmonary edema

    International Nuclear Information System (INIS)

    Mason, G.R.; Effros, R.M.; Uszler, J.M.; Mena, I.

    1985-01-01

    The regional clearance of /sup 99m/Tc-diethylenetriamine penta-acetate from the lungs was measured in 14 patients with noncardiogenic pulmonary edema, six patients with acute pulmonary edema secondary to heart failure, and 29 normal subjects. The radionuclide was delivered in an aerosol which was inhaled for 120 seconds, and the subsequent decline of radioactivity from the lungs was monitored for seven minutes over each of six peripheral regions of interest with a computerized scintillation camera. The average /sup 99m/Tc-DTPA clearance of these regions was accelerated above the 98 percent confidence limits in all but three of the patients with noncardiogenic edema. The mean clearance value in this group of patients was significantly greater than those in normal subjects or patients with cardiogenic pulmonary edema. Clearances returned toward normal in each of seven subjects who improved clinically. Only one of the patients with cardiogenic pulmonary edema had an elevated average clearance rate, and the mean clearance for this population was not statistically greater than normal. This procedure appears to detect increased epithelial permeability caused by lung injury and may help distinguish between cardiogenic and noncardiogenic pulmonary edema

  2. Waste-clearance strategy for DOE waste processed at commercial facilities

    International Nuclear Information System (INIS)

    Chen, S.Y.; Pfingston, M.; LePoire, D.

    1996-01-01

    In May 1991, a moratorium was issued on shipping potentially mixed waste from DOE facilities nationwide to commercial treatment, storage, and disposal facilities. A potential waste-clearance strategy was developed to address the DOE mixed-waste moratorium issues, which had resulted from a lack of exisitng volume contamination regulations. This strategy also has important potential applications for establishing site clearance limits that ensure worker and public risks remain well below regulatory limits

  3. Plasma clearance of noradrenaline does not change with age in normal subjects

    DEFF Research Database (Denmark)

    Hilsted, J; Christensen, N J; Larsen, S

    1985-01-01

    Noradrenaline kinetics (plasma concentrations, plasma clearance and appearance rates) were investigated in seven elderly healthy subjects and in six young healthy subjects. Forearm venous plasma noradrenaline concentrations were higher in the elderly subjects compared with the young subjects. Pla....... Plasma clearance of noradrenaline was identical in the two groups. The increase in plasma noradrenaline concentration, with age, probably reflects an increased sympathetic nervous activity.......Noradrenaline kinetics (plasma concentrations, plasma clearance and appearance rates) were investigated in seven elderly healthy subjects and in six young healthy subjects. Forearm venous plasma noradrenaline concentrations were higher in the elderly subjects compared with the young subjects...

  4. The kidneys play a central role in the clearance of rhGH in rats

    DEFF Research Database (Denmark)

    Vestergaard, Bill; Thygesen, Peter; Kreilgaard, Mads

    2016-01-01

    at treatment of patients with growth hormone disorders. The purpose of this study was to investigate the relative importance of the kidneys in the clearance of rhGH. The study employed a newly validated nephrectomy rat model and a population based pharmacokinetic approach to assess renal clearance of rh...... that renal clearance plays a pivotal role in the elimination of rhGH in rats....

  5. Low ground clearance vehicle detection and warning.

    Science.gov (United States)

    2015-06-01

    A Low Ground Clearance Vehicle Detection : System (LGCVDS) determines if a commercial : motor vehicle can successfully clear a highwayrail : grade crossing and notifies the driver when : his or her vehicle cannot safely traverse the : crossing. That ...

  6. The tribological behaviour of different clearance MOM hip joints with lubricants of physiological viscosities.

    Science.gov (United States)

    Hu, X Q; Wood, R J K; Taylor, A; Tuke, M A

    2011-11-01

    Clearance is one of the most influential parameters on the tribological performance of metal-on-metal (MOM) hip joints and its selection is a subject of considerable debate. The objective of this paper is to study the lubrication behaviour of different clearances for MOM hip joints within the range of human physiological and pathological fluid viscosities. The frictional torques developed by MOM hip joints with a 50 mm diameter were measured for both virgin surfaces and during a wear simulator test. Joints were manufactured with three different diametral clearances: 20, 100, and 200 microm. The fluid used for the friction measurements which contained different ratios of 25 percent newborn calf serum and carboxymethyl cellulose (CMC) with the obtained viscosities values ranging from 0.001 to 0.71 Pa s. The obtained results indicate that the frictional torque for the 20 microm clearance joint remains high over the whole range of the viscosity values. The frictional torque of the 100 microm clearance joint was low for the very low viscosity (0.001 Pa s) lubricant, but increased with increasing viscosity value. The frictional torque of the 200 microm clearance joint was high at very low viscosity levels, however, it reduced with increasing viscosity. It is concluded that a smaller clearance level can enhance the formation of an elastohydrodynamic lubrication (EHL) film, but this is at the cost of preventing fluid recovery between the bearing surfaces during the unloaded phase of walking. Larger clearance bearings allow a better recovery of lubricant during the unloaded phase, which is necessary for higher viscosity lubricants. The selection of the clearance value should therefore consider both the formation of the EHL film and the fluid recovery as a function of the physiological viscosity in order to get an optimal tribological performance for MOM hip joints. The application of either 25 per cent bovine serum or water in existing in vitro tribological study should

  7. Proficiency testing criteria for clearance level in solid waste gamma measurement in Taiwan.

    Science.gov (United States)

    Chen, Chun-Liang; Wang, Jeng-Jong; Chiu, Huang-Sheng

    2013-11-01

    To guarantee the measurement quality for clearance level in solid waste material, the Institute of Nuclear Energy Research (INER) established the criteria for proficiency testing of clearance level measurement. INER and the Taiwan Accreditation Foundation (TAF) organized the Technique Committee Meeting twice to discuss these criteria in 2011. The participating laboratories must completely conform to the ISO/IEC 17025, and they also must meet the requirements of the criteria. According to the criteria, the participating laboratories analyzed the minimum detectable amount (MDA) and that should be less than 20% of the clearance level (AMDA) given in the Atomic Energy Council's (AEC) "Regulations on Clearance Level for Radioactive Waste Management". The testing results should conform to the deviation and traceability requirements. Copyright © 2013 Elsevier Ltd. All rights reserved.

  8. Not All Children with Cystic Fibrosis Have Abnormal Esophageal Neutralization during Chemical Clearance of Acid Reflux.

    Science.gov (United States)

    Woodley, Frederick W; Moore-Clingenpeel, Melissa; Machado, Rodrigo Strehl; Nemastil, Christopher J; Jadcherla, Sudarshan R; Hayes, Don; Kopp, Benjamin T; Kaul, Ajay; Di Lorenzo, Carlo; Mousa, Hayat

    2017-09-01

    Acid neutralization during chemical clearance is significantly prolonged in children with cystic fibrosis, compared to symptomatic children without cystic fibrosis. The absence of available reference values impeded identification of abnormal findings within individual patients with and without cystic fibrosis. The present study aimed to test the hypothesis that significantly more children with cystic fibrosis have acid neutralization durations during chemical clearance that fall outside the physiological range. Published reference value for acid neutralization duration during chemical clearance (determined using combined impedance/pH monitoring) was used to assess esophageal acid neutralization efficiency during chemical clearance in 16 children with cystic fibrosis (3 to chemical clearance exceeded the upper end of the physiological range in 9 of 16 (56.3%) children with and in 3 of 16 (18.8%) children without cystic fibrosis ( p =0.0412). The likelihood ratio for duration indicated that children with cystic fibrosis are 2.1-times more likely to have abnormal acid neutralization during chemical clearance, and children with abnormal acid neutralization during chemical clearance are 1.5-times more likely to have cystic fibrosis. Significantly more (but not all) children with cystic fibrosis have abnormally prolonged esophageal clearance of acid. Children with cystic fibrosis are more likely to have abnormal acid neutralization during chemical clearance. Additional studies involving larger sample sizes are needed to address the importance of genotype, esophageal motility, composition and volume of saliva, and gastric acidity on acid neutralization efficiency in cystic fibrosis children.

  9. Technetium-99m mercaptoacetyltriglycine clearance values in children with minimal renal disease: can a normal range be determined?

    International Nuclear Information System (INIS)

    Meyer, G.; Hahn, K.; Piepsz, A.; Kolinska, J.; Lepej, J.; Sixt, R.

    1998-01-01

    Use of technetium-99m labelled mercaptoacetyltriglycine ( 99m Tc-MAG3) simplifies and improves the quantification of renal clearance in children by virtue of its permanent availability, good imaging properties and low radiation exposure. Due to the lack of reference values for 99m Tc-MAG3 clearance in children, the Paediatric Task Group of the EANM initiated a multicentre study to evaluate 99m Tc-MAG3 clearance values in children with minimal renal disease. One hundred and twenty-five children aged between 12 months and 17 years, classified as renally healthy using defined diagnostic criteria, were included in the study. 99m Tc-MAG3 clearance was calculated using an algorithm on the basis of a single blood sample taken at any time between 30 and 40 min after tracer injection. In addition, the absolute 99m -Tc-MAG3 clearance values were normalized to body surface area. For further evaluation the children were classified into several groups according to age. There was a continuous increase in non-corrected 99m Tc-MAG3 clearance values from the age of 1 year up to the age of 17 years (mean value 8 years: 208±66 ml/min). Normal clearance values for adults were achieved by the age of 8 years. Analysis of the relationship between non-corrected clearance and age yielded a correlation coefficient of r=0.7. When these absolute clearance values were normalized to body surface area, we found nearly constant clearance values for all age groups, with a mean clearance value of 315±114 ml/min x 1.73 m 2 . The correlation coefficient for the relationship between normalized clearance and age was r=0.28. In conclusion, the clearance of 99m Tc-MAG3 increases continuously throughout childhood into adolescence due to the maturation and growth of the kidney. After normalization of the absolute clearance to body surface area, no correlation between clearance and age could be proven. (orig.)

  10. Dextran fractional clearance studies in acute dengue infection.

    Directory of Open Access Journals (Sweden)

    Julie Nguyen-Pouplin

    2011-08-01

    Full Text Available Although increased capillary permeability is the major clinical feature associated with severe dengue infections the mechanisms underlying this phenomenon remain unclear. Dextran clearance methodology has been used to investigate the molecular sieving properties of the microvasculature in clinical situations associated with altered permeability, including during pregnancy and in various renal disorders. In order to better understand the characteristics of the vascular leak associated with dengue we undertook formal dextran clearance studies in Vietnamese dengue patients and healthy volunteers.We carried out serial clearance studies in 15 young adult males with acute dengue and evidence of vascular leakage a during the phase of maximal leakage and b one and three months later, as well as in 16 healthy control subjects. Interestingly we found no difference in the clearance profiles of neutral dextran solutions among the dengue patients at any time-point or in comparison to the healthy volunteers.The surface glycocalyx layer, a fibre-matrix of proteoglycans, glycosaminoglycans, and plasma proteins, forms a complex with the underlying endothelial cells to regulate plasma volume within circumscribed limits. It is likely that during dengue infections loss of plasma proteins from this layer alters the permeability characteristics of the complex; physical and/or electrostatic interactions between the dextran molecules and the glycocalyx structure may temporarily restore normal function, rendering the technique unsuitable for assessing permeability in these patients. The implications for resuscitation of patients with dengue shock syndrome (DSS are potentially important. It is possible that continuous low-dose infusions of dextran may help to stabilize the permeability barrier in patients with profound or refractory shock, reducing the need for repeated boluses, limiting the total colloid volume required. Formal clinical studies should help to assess

  11. Surface code—biophysical signals for apoptotic cell clearance

    International Nuclear Information System (INIS)

    Biermann, Mona; Maueröder, Christian; Brauner, Jan M; Chaurio, Ricardo; Herrmann, Martin; Muñoz, Luis E; Janko, Christina

    2013-01-01

    Apoptotic cell death and the clearance of dying cells play an important and physiological role in embryonic development and normal tissue turnover. In contrast to necrosis, apoptosis proceeds in an anti-inflammatory manner. It is orchestrated by the timed release and/or exposure of so-called ‘find-me’, ‘eat me’ and ‘tolerate me’ signals. Mononuclear phagocytes are attracted by various ‘find-me’ signals, including proteins, nucleotides, and phospholipids released by the dying cell, whereas the involvement of granulocytes is prevented via ‘stay away’ signals. The exposure of anionic phospholipids like phosphatidylserine (PS) by apoptotic cells on the outer leaflet of the plasma membrane is one of the main ‘eat me’ signals. PS is recognized by a number of innate receptors as well as by soluble bridging molecules on the surface of phagocytes. Importantly, phagocytes are able to discriminate between viable and apoptotic cells both exposing PS. Due to cytoskeleton remodeling PS has a higher lateral mobility on the surfaces of apoptotic cells thereby promoting receptor clustering on the phagocyte. PS not only plays an important role in the engulfment process, but also acts as ‘tolerate me’ signal inducing the release of anti-inflammatory cytokines by phagocytes. An efficient and fast clearance of apoptotic cells is required to prevent secondary necrosis and leakage of intracellular danger signals into the surrounding tissue. Failure or prolongation of the clearance process leads to the release of intracellular antigens into the periphery provoking inflammation and development of systemic inflammatory autoimmune disease like systemic lupus erythematosus. Here we review the current findings concerning apoptosis-inducing pathways, important players of apoptotic cell recognition and clearance as well as the role of membrane remodeling in the engulfment of apoptotic cells by phagocytes. (paper)

  12. Trend of research and development on clearance system for CBRNE agents

    International Nuclear Information System (INIS)

    Ishihara, Masayuki; Fujita, Masanori; Ishida, Natsuko; Hattori, Hidemi; Tachibana, Shoich; Nakamura, Shingo; Kanatani, Yasuhiro

    2013-01-01

    In a field of disaster for a wide variety of Chemical, Biological, Radiological, Nuclear, Explosive (CBRNE) agents which are harmful and deadly poisonous, it is crucial to effectively clear those agents for prevention of expanded damages and retrieval from damage. The clearance technologies in the CBRNE disaster field require to be safe for human body and to be friendly for the environments. In addition, they need scientific data-based evidences for their effectiveness and safety. The aim of this article is to view the trend of research on clearances of N, B and c agents in terms of rapidity, simplicity and economic rationality, and to deliberate on effective clearance system using adequate equipments and materials for detoxification, decomposition and removal of each contamination. (author)

  13. Rate-Based Model Predictive Control of Turbofan Engine Clearance

    Science.gov (United States)

    DeCastro, Jonathan A.

    2006-01-01

    An innovative model predictive control strategy is developed for control of nonlinear aircraft propulsion systems and sub-systems. At the heart of the controller is a rate-based linear parameter-varying model that propagates the state derivatives across the prediction horizon, extending prediction fidelity to transient regimes where conventional models begin to lose validity. The new control law is applied to a demanding active clearance control application, where the objectives are to tightly regulate blade tip clearances and also anticipate and avoid detrimental blade-shroud rub occurrences by optimally maintaining a predefined minimum clearance. Simulation results verify that the rate-based controller is capable of satisfying the objectives during realistic flight scenarios where both a conventional Jacobian-based model predictive control law and an unconstrained linear-quadratic optimal controller are incapable of doing so. The controller is evaluated using a variety of different actuators, illustrating the efficacy and versatility of the control approach. It is concluded that the new strategy has promise for this and other nonlinear aerospace applications that place high importance on the attainment of control objectives during transient regimes.

  14. A parameters optimization method for planar joint clearance model and its application for dynamics simulation of reciprocating compressor

    Science.gov (United States)

    Hai-yang, Zhao; Min-qiang, Xu; Jin-dong, Wang; Yong-bo, Li

    2015-05-01

    In order to improve the accuracy of dynamics response simulation for mechanism with joint clearance, a parameter optimization method for planar joint clearance contact force model was presented in this paper, and the optimized parameters were applied to the dynamics response simulation for mechanism with oversized joint clearance fault. By studying the effect of increased clearance on the parameters of joint clearance contact force model, the relation of model parameters between different clearances was concluded. Then the dynamic equation of a two-stage reciprocating compressor with four joint clearances was developed using Lagrange method, and a multi-body dynamic model built in ADAMS software was used to solve this equation. To obtain a simulated dynamic response much closer to that of experimental tests, the parameters of joint clearance model, instead of using the designed values, were optimized by genetic algorithms approach. Finally, the optimized parameters were applied to simulate the dynamics response of model with oversized joint clearance fault according to the concluded parameter relation. The dynamics response of experimental test verified the effectiveness of this application.

  15. Cerebrospinal fluid clearance in Alzheimer disease measured with dynamic PET

    DEFF Research Database (Denmark)

    De Leon, Mony J.; Li, Yi; Okamura, Nobuyuki

    2017-01-01

    Evidence supporting the hypothesis that reduced cerebrospinal fluid (CSF) clearance is involved in the pathophysiology of Alzheimer disease (AD) comes primarily from rodent models. However, unlike rodents, in which predominant extracranial CSF egress is via olfactory nerves traversing the cribrif......Evidence supporting the hypothesis that reduced cerebrospinal fluid (CSF) clearance is involved in the pathophysiology of Alzheimer disease (AD) comes primarily from rodent models. However, unlike rodents, in which predominant extracranial CSF egress is via olfactory nerves traversing...

  16. Influence of tip clearance on flow behavior and noise generation of centrifugal compressors in near-surge conditions

    International Nuclear Information System (INIS)

    Galindo, J.; Tiseira, A.; Navarro, R.; López, M.A.

    2015-01-01

    Highlights: • Centrifugal compressor aeroacoustics sensitivity to tip clearance is investigated. • 3 different clearance ratios are set in accordance to expected operating values. • Pressure spectra do not depend on tip clearance ratio in near-surge conditions. • DES performs better than URANS in predicting compressor acoustic signature. • Flow field observation reveals that tip clearance is immersed in rotating backflow. - Abstract: CFD has become an essential tool for researchers to analyze centrifugal compressors. Tip leakage flow is usually considered one of the main mechanisms that dictate compressor flow field and stability. However, it is a common practice to rely on CAD tip clearance, even though the gap between blades and shroud changes when compressor is running. In this paper, sensitivity of centrifugal compressor flow field and noise prediction to tip clearance ratio is investigated. 3D CFD simulations are performed with three different tip clearance ratios in accordance to expected operating values, extracted from shaft motion measurements and FEM predictions of temperature and rotational deformation. Near-surge operating conditions are simulated with URANS and DES. DES shows superior performance for acoustic predictions. Cases with reduced tip clearance present higher pressure ratio and isentropic efficiency, but no significant changes in compressor acoustic signature are found when varying clearance. In this working point, tip clearance is immersed in a region of strongly swirling backflow. Therefore, tip leakage cannot establish any coherent noise source mechanism

  17. Decreased insulin clearance in individuals with elevated 1-h post-load plasma glucose levels.

    Directory of Open Access Journals (Sweden)

    Maria Adelaide Marini

    Full Text Available Reduced insulin clearance has been shown to predict the development of type 2 diabetes. Recently, it has been suggested that plasma glucose concentrations ≥ 8.6 mmol/l (155 mg/dl at 1 h during an oral glucose tolerance test (OGTT can identify individuals at high risk for type 2 diabetes among those who have normal glucose tolerance (NGT 1 h-high. The aim of this study was to examine whether NGT 1 h-high have a decrease in insulin clearance, as compared with NGT individuals with 1-h post-load glucose <8.6 mmol/l (l (155 mg/dl, NGT 1 h-low. To this end, 438 non-diabetic White individuals were subjected to OGTT and euglycemic-hyperinsulinemic clamp to evaluate insulin clearance and insulin sensitivity. As compared with NGT 1 h-low individuals, NGT 1 h-high had significantly higher 1-h and 2-h post-load plasma glucose and 2-h insulin levels as well as higher fasting glucose and insulin levels. NGT 1 h-high exhibited also a significant decrease in both insulin sensitivity (P<0.0001 and insulin clearance (P = 0.006 after adjusting for age, gender, adiposity measures, and insulin sensitivity. The differences in insulin clearance remained significant after adjustment for fasting glucose (P = 0.02 in addition to gender, age, and BMI. In univariate analyses adjusted for gender and age, insulin clearance was inversely correlated with body weight, body mass index, waist, fat mass, 1-h and 2-h post-load glucose levels, fasting, 1-h and 2-h post-load insulin levels, and insulin-stimulated glucose disposal. In conclusion, our data show that NGT 1 h-high have a reduction in insulin clearance as compared with NGT 1 h-low individuals; this suggests that impaired insulin clearance may contribute to sustained fasting and post-meal hyperinsulinemia.

  18. The Swedish nuclear industry way to approach higher demands on characterisation prior to clearance

    International Nuclear Information System (INIS)

    Larsson, Arne; Hellsten, Erik; Berglund, Malin; Larsson, Lars

    2012-01-01

    The Swedish Radiation Safety Authority (SSM) has introduced new regulations for clearance SSMFS 2011:2 'Regulations concerning clearance of material, rooms, buildings and soil from activities with ionizing radiation'. The new regulations came into force January 1, 2012. Compared to the previous regulations these new regulations have a broader scope and have introduced new conditions such as nuclide specific clearance levels. Clearance is practiced to reduce the amount of radioactive waste generated. Cleared material can be reused, recycled or if these two possibilities are not available, disposed of as conventional waste. To be able to meet the requirements for clearance the Swedish nuclear industry has jointly developed guidance for clearance in the form of a handbook and a training course covering the competence requirements in the new regulations. The handbook was developed by a team of representatives from the Swedish nuclear license holders managed by Studsvik on behalf of Swedish Nuclear Fuel and Waste Management Company (SKB). The training program was developed in co-operation between Nuclear Safety and training Company (KSU) and Studsvik on behalf of the Swedish nuclear license holders. A major challenge in the adoption to the new regulations is how to provide robust yet cost effective characterisation data. This is especially difficult for mobile materials and equipment which cannot be fully tracked but also for other materials and areas where the nuclide fingerprint has varied over the years. To be able to deal with these issues a lot of attention has to be paid to the historical inventory records and traceability in the clearance process. Materials, rooms and buildings have been divided in four categories with different requirements on frequency and requirements of measurements. The categories are named 'extremely small risk', 'small risk', 'risk' and 'known contamination above clearance levels'. The two day training course is dived into seven parts

  19. Quantitative assessment of caffeine partial clearances in man.

    Science.gov (United States)

    Lelo, A; Miners, J O; Robson, R A; Birkett, D J

    1986-01-01

    Five subjects who participated in an earlier study (Lelo et al., 1986b) of the comparative pharmacokinetics of caffeine (CA) and its primary monodemethylated metabolites paraxanthine (PX), theobromine (TB) and theophylline (TP) were administered CA to steady-state. Using areas under the plasma concentration-time curves for each of the dimethylxanthines derived from CA in the steady-state study and individual plasma clearances of PX, TB and TP determined in the previous study, the fractional conversion of CA to PX, TB and TP and the individual partial clearances of CA have been defined. The mean (+/- s.d.) fractional conversion of CA to PX, TB and TP was 79.6 +/- 21.0%, 10.8 +/- 2.4% and 3.7 +/- 1.3%, respectively. When only demethylation pathways are considered PX, TB and TP accounted for 83.9 +/- 5.4%, 12.1 +/- 4.1% and 4.0 +/- 1.4%, respectively of the CA demethylations. The mean partial clearance of CA to PX was approximately 8-fold and 23-fold greater than those to TB and TP respectively. These data confirm earlier reports that PX is the major metabolite of CA in humans but suggest that PX formation is quantitatively more important than previously believed. PMID:3756066

  20. Decision Assessment of Clearance Level on Radioactive Waste Management

    International Nuclear Information System (INIS)

    Zainus Salimin; Gunandjar

    2007-01-01

    Radioactive waste on the safe level activity containing very small radioactive material gives small radiology influence to the human, it is not necessary to control by regulatory body. The radioactive waste on the safe level activity is safe to release as the common waste. For exemption of the control, it is required the safe activity level limits in which the value of clearance level is fulfilled by regulatory body, however until now it is not decided yet. The exemption decision is obtained if its activity is lower than or same with clearance level based on the annual effective dose receiving by public on the value is lower than or same with 0,01 mSv. The exposure pathways of radioactive waste to the human have important role for determination of clearance level. The decision assessment of clearance level on the radioactive waste management has been done by analysis of radioactive exposure pathways to the human for activities of the disposal and the recycle of solid wastes, also the release of liquid and gas effluent. For solid waste disposal, the exposure pathway was evaluated since the transportation of packed waste from the treatment facility to the disposal facility and during its operation. Exposure pathways for solid waste recycle consist of the pathways for handling and transportation of cleared material to the recycling facility, the fabrication and the utilization of its product. Exposure pathways for liquid and gas releases occur since its releases to the environment up to the human (public) by specific traffic lane. (author)

  1. Bromsulphalein (BSP) clearance in ageing rats

    NARCIS (Netherlands)

    Hollander, C.F.; Leeuw-Israel, F.R. de; Arp-Neefjes, J.M.

    1968-01-01

    Liver function in ageing rats was studied, using the bromsulphalein (BSP) clearance test. The test was done on ultramicro scale. This made it possible to repeat the test several times in the same animal and to start a longitudinal study. In 3-month-old rats the BSP retentions, measured 15, 30 and 45

  2. DOE DISS/ET pilot system

    International Nuclear Information System (INIS)

    Strait, R.S.; Wagner, E.E.

    1994-01-01

    The U.S. Department of Energy (DOE) Office of Safeguards and Security initiated the DOE Integrated Security System/Electronic Transfer (DISS/ET) for the purpose of reducing the time required to process security clearance requests. DISS/ET will be an integrated system using electronic commerce technologies for the collection and processing of personnel security clearance data, and its transfer between DOE local security clearance offices, DOE Operations Offices, and the Office of Personnel Management. The system will use electronic forms to collect clearance applicant data. The forms data will be combined with electronic fingerprint images and packaged in a secure encrypted electronic mail envelope for transmission across the Internet. Information provided by the applicant will be authenticated using digital signatures. All processing will be done electronically

  3. Non-destructive clearance measuring in closed joints

    International Nuclear Information System (INIS)

    Doucelance, C.; Manaranche, J.C.

    1976-01-01

    Two methods for clearance measuring in closed joints are described. The first one is based on the mechanical impedance concept, while the other one requires a shock test on shaker. Both are illustrated with an example of application [fr

  4. Hyperinsulinism and polycystic ovary syndrome (PCOS): role of insulin clearance.

    Science.gov (United States)

    Amato, M C; Vesco, R; Vigneri, E; Ciresi, A; Giordano, C

    2015-12-01

    Insulin resistance and compensatory hyperinsulinism are the predominant metabolic defects in polycystic ovary syndrome (PCOS). However, hyperinsulinism, as well as being compensatory, can also express a condition of reduced insulin clearance. Our aim was to evaluate the differences in insulin action and metabolism between women with PCOS (with normal glucose tolerance) and age- and BMI-matched women with prediabetes (without hyperandrogenism and ovulatory disorders). 22 women with PCOS and 21 age/BMI-matched women with prediabetes were subjected to a Hyperinsulinemic-euglycemic clamp and an Oral Glucose tolerance Test (OGTT). Insulin sensitivity was assessed by the glucose infusion rate during clamp (M value); insulin secretion by Insulinogenic index, Oral Disposition Index (DIo) and AUC(2h-insulin) during OGTT; and insulin clearance by the metabolic clearance rate of insulin (MCRI) during clamp. Women with PCOS showed significantly higher levels of AUC(2h-insulin) (p PCOS [420 (IQR 227-588) vs. 743 (IQR 597-888) ml m(-2) min(-1): p PCOS group, a strong independent inverse correlation was only observed between MCRI and AUC(2h-insulin) (PCOS: β:-0.878; p PCOS there is peripheral insulin sensitivity similar to that of women with prediabetes. What sets PCOS apart is the hyperinsulinism, today still simplistically defined "compensatory"; actually this is mainly related to decreased insulin clearance whose specific causes and dynamics have yet to be clarified.

  5. 133 xenon muscle clearance as a test parameter in the diagnosis of peripheral diabetic angiopathies

    International Nuclear Information System (INIS)

    Kuhlmann, J.E.

    1980-01-01

    In 100 patients with manifest diabetes mellitus the irrigation in both legs at rest and in radioactive hyperemia after ischemic muscle work was measured by means of the 133-xenon muscle clearance. The clearance values measured ranged between 0.8 and 3.5 ml/100 g/60 s at rest and between 3.3 and 40.0 ml/100 gl/60 s during radioactive hyperemia. In 96 pc of the probands the irrigation of the legs was impaired. For the relation between glucose level and irrigation at rest a significant negative correlation was found. The difference between the clearance values for the right and left lower extremity was significant. For the relation between glucose level and reactive hyperemia, too, a significant negative correlation was found. The difference between the clearance values for the right and left lower extremities was significant. The measurement of the irrigation at rest showed no significant correlation between the period of manifestation of the diabetes and the clearance values. By contrast, the irrigation values during reactive hyperemia were shown to be in significantly negative correlation to the duration of the diabetes. No connection was found between the frequency of diabetic gangrene and impaired irrigation at rest. By contrast, there was a relation between decreasing hyperemia values and increased frequency of gangrene. A collection of case histories shows how the measuring results of the xenon clearance fit into the overall clinical picture. A comparison of xenon clearance with other methods of irrigation measurement confirmed obvious advantages of xenon clearance for the detection of diabetic microangiopathies. (orig./MG) [de

  6. Serial thallium-201 imaging after dipyridamole for coronary disease detection: quantitative analysis using myocardial clearance

    International Nuclear Information System (INIS)

    Okada, R.D.; Dai, Y.H.; Boucher, C.A.; Pohost, G.M.

    1984-01-01

    After dipyridamole, canine studies have demonstrated a slower rate of myocardial thallium-201 clearance from zones distal to a coronary artery stenosis compared to normal zones. To determine if criteria based on canine myocardial thallium-201 clearance rates could be applied clinically, 40 patients with and 26 patients without coronary artery disease (CAD) had serial thallium-201 images obtained for 2 to 5 hours after dipyridamole. Regions of interest were manually placed over six left ventricular segments in two projections for each of three imaging times. The myocardial thallium-201 clearance rate was calculated for each of the six segments and, using the clearance rate criterion found in canine studies, was considered abnormal if less than 6.5%/hr. Using this criterion alone, 22 of 26 patients (85%) without CAD had normal and 30 of 40 patients (75%) with CAD had abnormal myocardial thallium-201 clearance rates. A quantitative analysis of regional inhomogeneity in tracer distribution (normal was greater than or equal to 25% difference between segments) was negative in 24 of 26 patients (92%) without CAD and positive in 20 of 40 patients (50%) with CAD. When both clearance rate and regional inhomogeneity were considered, 21 of 26 patients (81%) without CAD had negative and 36 of 40 patients (90%) with CAD had positive results. Thus, post-dipyridamole myocardial clearance rate criteria derived from canine studies can be applied to clinical thallium imaging. Quantitative analysis of serial thallium-201 images after dipyridamole is optimized by using myocardial thallium-201 clearance rates. Such an approach is independent of regional inhomogeneities in tracer distribution

  7. TAM receptors in apoptotic cell clearance, autoimmunity, and cancer.

    Science.gov (United States)

    Nguyen, Khanh-Quynh; Tsou, Wen-I; Kotenko, Sergei; Birge, Raymond B

    2013-08-01

    Receptor tyrosine kinases, Tyro-3, Axl and Mer, collectively designated as TAM, are involved in the clearance of apoptotic cells. TAM ligands, Gas6 and Protein S, bind to the surfaces of apoptotic cells, and at the same time, interact directly with TAM expressed on phagocytes, impacting the engulfment and clearance of apoptotic cells and debris. The well-tuned and balanced actions of TAM may affect a variety of human pathologies including autoimmunity, retinal degeneration, and cancer. This article emphasizes some of the emerging findings and mechanistic insights into TAM functions that are clinically relevant and possibly therapeutically targeted.

  8. Clearance of buildings for demolition: ways to clearance on the standing structure for covered surfaces and inaccessible areas

    International Nuclear Information System (INIS)

    Thraenert, S.; Riemann, T.

    2014-01-01

    In general terms, the TUV NORD Nuclear services encompass safety assessments, design reviews, documentation re-views and inspections. They reflect the full scope of a technical service provider in the nuclear field. In the domestic market, these services are provided for the regulator, whereas in the international market any party involved in a nuclear project is a potential customer of TUV NORD Nuclear. This implies that TUV NORD Nuclear is offering consultancy, engineering and inspection services. Regarding the clearance of buildings for demolition, there are two different possible ways for the radiological characterization. The first option is a characterization on the standing structure before demolition and the second option is the characterization of the building rubble after demolition. According to the German Radiation Protection Ordinance, buildings of decommissioned nuclear sites have to be preferentially cleared on the standing structure. If compliance with the surface specific clearance levels is achieved on the standing structure, usually the cleared buildings can be demolished and the resulting rubble may be used without any further radiological considerations. In the case of the former nuclear power plant Wuergassen the majority of the building rubble is scheduled to stay on site to serve as backfill for the building pit. As such a scenario was not considered in the radiological considerations of, e.g., the German Radiation Protection Ordinance, an additional dose calculation was carried out for Wuergassen NPP basing on its radiological characteristics to directly prove compliance with the de-minimis-concept. The radiation controlled area (RCA) of Wuergassen NPP comprises an area of about 140.000 m 2 . This area is more or less easily accessible to characterization and decontamination using, if necessary, scaffoldings or lifting platforms. Up to the beginning of 2013, compliance with the surface specific clearance levels was verified on the standing

  9. Lithium clearance and renal tubular sodium handling during acute and long-term nifedipine treatment in essential hypertension

    DEFF Research Database (Denmark)

    Bruun, N E; Ibsen, H; Skøtt, P

    1988-01-01

    1. In two separate studies the lithium clearance method was used to evaluate the influence of acute and long-term nifedipine treatment on renal tubular sodium reabsorption. 2. In the acute study, after a 4 week placebo period two doses of 20 mg of nifedipine decreased supine blood pressure from 155...... were also unchanged, as were potassium clearance, urine flow and body weight. 3. In the long-term study, lithium clearance, glomerular filtration rate, sodium clearance, potassium clearance, urine flow and body fluid volumes were measured after a 4 weeks placebo period and after 6 and 12 weeks....../101 (20.6/13.5) +/- 11/4 (1.5/0.5) to 139/88 (18.5/11.7) +/- 16/9 (2.1/1.2) mmHg (kPa) (means +/- SD; P less than 0.01). Lithium clearance, glomerular filtration rate and sodium clearance did not change. Therefore the calculated values of absolute proximal and absolute distal sodium reabsorption rates...

  10. Effect of tip clearance on performance of small axial hydraulic turbine

    Science.gov (United States)

    Boynton, J. L.; Rohlik, H. E.

    1976-01-01

    The first two stages of a six stage liquid oxygen turbine were tested in water. One and two stage performance was determined for one shrouded and two unshrouded blade end configurations over ranges of clearance and blade-jet speed ratio. First stage, two stage, and second stage efficiencies are included as well as the effect of clearance on mass flow for two stage operation.

  11. Thickness and clearance visualization based on distance field of 3D objects

    Directory of Open Access Journals (Sweden)

    Masatomo Inui

    2015-07-01

    Full Text Available This paper proposes a novel method for visualizing the thickness and clearance of 3D objects in a polyhedral representation. The proposed method uses the distance field of the objects in the visualization. A parallel algorithm is developed for constructing the distance field of polyhedral objects using the GPU. The distance between a voxel and the surface polygons of the model is computed many times in the distance field construction. Similar sets of polygons are usually selected as close polygons for close voxels. By using this spatial coherence, a parallel algorithm is designed to compute the distances between a cluster of close voxels and the polygons selected by the culling operation so that the fast shared memory mechanism of the GPU can be fully utilized. The thickness/clearance of the objects is visualized by distributing points on the visible surfaces of the objects and painting them with a unique color corresponding to the thickness/clearance values at those points. A modified ray casting method is developed for computing the thickness/clearance using the distance field of the objects. A system based on these algorithms can compute the distance field of complex objects within a few minutes for most cases. After the distance field construction, thickness/clearance visualization at a near interactive rate is achieved.

  12. Energy Performance and Radial Force of a Mixed-Flow Pump with Symmetrical and Unsymmetrical Tip Clearances

    Directory of Open Access Journals (Sweden)

    Yue Hao

    2017-01-01

    Full Text Available The energy performance and radial force of a mixed flow pump with symmetrical and unsymmetrical tip clearance are investigated in this paper. As the tip clearance increases, the pump head and efficiency both decrease. The center of the radial force on the principal axis is located at the coordinate origin when the tip clearance is symmetrical, and moves to the third quadrant when the tip clearance is unsymmetrical. Analysis results show that the total radial force on the principal axis is closely related to the fluctuation of mass flow rate in each single flow channel. Unsteady simulations show that the dominant frequencies of radial force on the hub and blade correspond to the blade number, vane number, or double blade number because of the rotor stator interaction. The radial force on the blade pressure side decreases with the tip clearance increase because of leakage flow. The unsymmetrical tip clearances in an impeller induce uneven leakage flow rate and then result in unsymmetrical work ability of each blade and flow pattern in each channel. Thus, the energy performance decreases and the total radial force increases for a mixed flow pump with unsymmetrical tip clearance.

  13. 76 FR 24920 - Agency Information Collection Activities: Proposed Collection; Comment Request; Generic Clearance...

    Science.gov (United States)

    2011-05-03

    ... precision requirements or power calculations that justify the proposed sample size, the expected response... Collection; Comment Request; Generic Clearance for the Collection of Qualitative Feedback on Agency Service... Information Collection Request (Generic ICR): ``Generic Clearance for the Collection of Qualitative Feedback...

  14. 76 FR 35069 - Agency Information Collection Activities; Proposed Collection; Comment Request; Generic Clearance...

    Science.gov (United States)

    2011-06-15

    ... precision requirements or power calculations that justify the proposed sample size, the expected response...; Proposed Collection; Comment Request; Generic Clearance for the Collection of Qualitative Feedback on... (Generic ICR): ``Generic Clearance for the Collection of Qualitative Feedback on Agency Service Delivery...

  15. 78 FR 74175 - Agency Information Collection Activities: Proposed Collection; Comment Request; Generic Clearance...

    Science.gov (United States)

    2013-12-10

    ... precision requirements or power calculations that justify the proposed sample size, the expected response...: Proposed Collection; Comment Request; Generic Clearance for the Collection of Qualitative Feedback on... Information Collection Request (Generic ICR): ``Generic Clearance for the Collection of Qualitative Feedback...

  16. 77 FR 52708 - Agency Information Collection Activities: Proposed Collection; Comment Request; Generic Clearance...

    Science.gov (United States)

    2012-08-30

    ... calculations that justify the proposed sample size, the expected response rate, methods for assessing potential...: Proposed Collection; Comment Request; Generic Clearance for the Collection of Qualitative Feedback on... Information Collection request (Generic ICR): ``Generic Clearance for the Collection of Qualitative Feedback...

  17. 76 FR 9819 - Agency Information Collection Activities: Proposed Collection; Generic Clearance for the...

    Science.gov (United States)

    2011-02-22

    ...; Generic Clearance for the Collection of Qualitative Feedback on Agency Service Delivery; Correction AGENCY...: Proposed Collection; Comment Request; Generic Clearance for the Collection of Qualitative Feedback on... Regulatory Commission, Office of Personnel Management, Small Business Administration, and U.S. Agency for...

  18. Turbine Engine Clearance Control Systems: Current Practices and Future Directions

    Science.gov (United States)

    Lattime, Scott B.; Steinetz, Bruce M.

    2002-01-01

    Improved blade tip sealing in the high pressure compressor (HPC) and high pressure turbine (HPT) can provide dramatic reductions in specific fuel consumption (SFC), time-on-wing, compressor stall margin, and engine efficiency as well as increased payload and mission range capabilities. Maintenance costs to overhaul large commercial gas turbine engines can easily exceed $1M. Engine removal from service is primarily due to spent exhaust gas temperature (EGT) margin caused mainly by the deterioration of HPT components. Increased blade tip clearance is a major factor in hot section component degradation. As engine designs continue to push the performance envelope with fewer parts and the market drives manufacturers to increase service life, the need for advanced sealing continues to grow. A review of aero gas turbine engine HPT performance degradation and the mechanisms that promote these losses are discussed. Benefits to the HPT due to improved clearance management are identified. Past and present sealing technologies are presented along with specifications for next generation engine clearance control systems.

  19. Regulation Concepts for Clearance Level of Radionuclide in Solid Materials

    International Nuclear Information System (INIS)

    Nanang Triagung Edi Hermawan

    2008-01-01

    Practices of nuclear energy have expanded in some fields such as researches and development, educations, agricultures, medicines and industries. Every practice beside give much benefit, could generate residue or waste. Radioactive waste needs management to ensure the safety of workers, member of the public, and for the eternal of environment. The product of radioactive waste management, in generally, is some containment of radionuclide concentration in solid matrix material after immobilization or conditioning process. Some kind of processed radioactive wastes with short half live then decay faster to stabile condition. The decay will reach clearance level in sometimes, so from the radiation protection views is harmless. This materials above didn’t need control and must be cleared from all determinate and regulation aspects of radioactive material practices. There is clearance for harmless material off course will be simplify management task and efficiency of money. So the regulation about clearance levels will be important as law basic for technical practices in field. (author)

  20. Dynamic Studies of Lung Fluid Clearance with Phase Contrast Imaging

    International Nuclear Information System (INIS)

    Kitchen, Marcus J.; Williams, Ivan; Irvine, Sarah C.; Morgan, Michael J.; Paganin, David M.; Lewis, Rob A.; Pavlov, Konstantin; Hooper, Stuart B.; Wallace, Megan J.; Siu, Karen K. W.; Yagi, Naoto; Uesugi, Kentaro

    2007-01-01

    Clearance of liquid from the airways at birth is a poorly understood process, partly due to the difficulties of observing and measuring the distribution of air within the lung. Imaging dynamic processes within the lung in vivo with high contrast and spatial resolution is therefore a major challenge. However, phase contrast X-ray imaging is able to exploit inhaled air as a contrast agent, rendering the lungs of small animals visible due to the large changes in the refractive index at air/tissue interfaces. In concert with the high spatial resolution afforded by X-ray imaging systems (<100 μm), propagation-based phase contrast imaging is ideal for studying lung development. To this end we have utilized intense, monochromatic synchrotron radiation, together with a fast readout CCD camera, to study fluid clearance from the lungs of rabbit pups at birth. Local rates of fluid clearance have been measured from the dynamic sequences using a single image phase retrieval algorithm

  1. Understanding of the Interaction between Clearance Leakage Flow and Main Passage Flow in a VGT Turbine

    Directory of Open Access Journals (Sweden)

    Ben Zhao

    2015-02-01

    Full Text Available The clearance flow between the nozzle and endwall in a variable geometry turbine (VGT has been numerically investigated to understand the clearance effect on the VGT performance and internal flow. It was found that the flow rate through turbine increases but the turbine efficiency decreases with height of clearance. Detailed flow field analyses indicated that most of the efficiency loss resulting from the leakage flow occurs at the upstream of the rotor area, that is, in the nozzle endwall clearance and between the nozzle vanes. There are two main mechanisms associated with this efficiency loss. One is due to the formation of the local vortex flow structure between the clearance flow and the main flow. The other is due to the impact of the clearance flow on the main flow after the nozzle throat. This impact reduces the span of shockwave with increased shockwave magnitude by changing the trajectory of the main flow.

  2. The effects of selected air pollutants on clearance of titanic oxide particles from the lungs of rats.

    Science.gov (United States)

    Ferin, J; Leach, L J

    1975-09-01

    A procedure utilizing the lung clearance kinetics of titanic oxide (TiO2) particles was used to determine the effects of inhaled sulphur dioxide (SO2) and nitrogen oxides (NO x) on particle clearance. The procedure is reproducible and mainly tests clearance mechanisms involving alveolar macrophages and the mucociliary transport system at the alveolobronchial clearance pathway. At low SO2 or NOx exposures enhanced particle clearance was observed. Lung clearance was depressed at 15 and 24 ppm of NO2 after 22 exposures as well as at 20 ppm of SO2 after 11 exposures, and also at 1 ppm of SO2 after 25 exposures. Dose-response curves for the SO2 and NOx exposures showed differences explainable by the routes by which these gases reach the alveolar macrophages.

  3. Automated Real-Time Clearance Analyzer (ARCA), Phase I

    Data.gov (United States)

    National Aeronautics and Space Administration — The Automated Real-Time Clearance Analyzer (ARCA) addresses the future safety need for Real-Time System-Wide Safety Assurance (RSSA) in aviation and progressively...

  4. 75 FR 38775 - Proposed Information Collection; Comment Request; Generic Clearance for Customer Satisfaction...

    Science.gov (United States)

    2010-07-06

    ...; Generic Clearance for Customer Satisfaction Research AGENCY: U.S. Census Bureau. ACTION: Notice. SUMMARY... Bureau is requesting an extension of the generic clearance to conduct customer satisfaction research... on feedback from its various customer satisfaction research efforts. Each research design is reviewed...

  5. 75 FR 80542 - Agency Information Collection Activities: Proposed Collection; Comment Request; Generic Clearance...

    Science.gov (United States)

    2010-12-22

    ... calculations that justify the proposed sample size, the expected response rate, methods for assessing potential...; Comment Request; Generic Clearance for the Collection of Qualitative Feedback on Agency Service Delivery... Collection Request (Generic ICR): ``Generic Clearance for the Collection of Qualitative Feedback on Agency...

  6. 76 FR 12140 - Agency Information Collection Activities: Proposed Collection; Comment Request; Generic Clearance...

    Science.gov (United States)

    2011-03-04

    ... calculations that justify the proposed sample size, the expected response rate, methods for assessing potential...; Comment Request; Generic Clearance for the Collection of Qualitative Feedback on Agency Service Delivery... Information Collection Request (Generic ICR): ``Generic Clearance for the Collection of Qualitative Feedback...

  7. 76 FR 19826 - Agency Information Collection Activities: Proposed Collection; Comment Request; Generic Clearance...

    Science.gov (United States)

    2011-04-08

    ... calculations that justify the proposed sample size, the expected response rate, methods for assessing potential... Request; Generic Clearance for the Collection of Qualitative Feedback on Agency Service Delivery AGENCY... (Generic ICR): ``Generic Clearance for the Collection of Qualitative Feedback on Agency Service Delivery...

  8. 76 FR 17861 - Agency Information Collection Activities: Proposed Collection; Comment Request; Generic Clearance...

    Science.gov (United States)

    2011-03-31

    ... requirements or power calculations that justify the proposed sample size, the expected response rate, methods...; Comment Request; Generic Clearance for the Collection of Qualitative Feedback on Agency Service Delivery... Information Collection Request (Generic ICR): ``Generic Clearance for the Collection of Qualitative Feedback...

  9. 76 FR 41280 - Agency Information Collection Activities: Proposed Collection; Comment Request; Generic Clearance...

    Science.gov (United States)

    2011-07-13

    ... proposed sample size, the expected response rate, methods for assessing potential non-response bias, the... Activities: Proposed Collection; Comment Request; Generic Clearance for the Collection of Qualitative...): ``Generic Clearance for the Collection of Qualitative Feedback on Agency Service Delivery '' to OMB for...

  10. 76 FR 25693 - Agency Information Collection Activities: Proposed Collection; Comment Request; Generic Clearance...

    Science.gov (United States)

    2011-05-05

    ... requirements or power calculations that justify the proposed sample size, the expected response rate, methods... Collection; Comment Request; Generic Clearance for the Collection of Qualitative Feedback on Agency Service... Collection Request (Generic ICR): ``Generic Clearance for the Collection of Qualitative Feedback on Agency...

  11. [Medical clearance for missions abroad (EEU): definitions, recommendations for use and performance].

    Science.gov (United States)

    Kollaritsch, Herwig; Wenisch, Christoph; Hatz, Christoph; von Laer, Gunther; Bauer, Bernd; Hollenstein, Ursula; Haditsch, Martin; Diridl, Gerhard; Malinowski, Waldemar; Jeschko, Eva; Payer-Neundlinger, Gabriela; Speiser-Remp, Nicole; Pichler, Hannes E T; Rumpold, Helmut; Stemberger, Heinrich; Eder, Gerald; Wiedermann, Gerhard; Wiedermann, Ursula

    2007-01-01

    Standards for medical clearance for private or business missions abroad are--at least in the German speaking countries--not clearly defined and mostly derived from the old terminus "Tropentauglichkeit" which means fit for mission in the tropics. The authors now define a new standard, called "Entsendungstauglichkeitsuntersuchung" which means clearance of fitness for all types of missions abroad, independent of distinct climatic zones. To meet the inhomogenous requirements of different institutions and different types of missions the medical examination proposed follows a modular structure to optimize economic and medical use of resources. Moreover, as Austria, Germany and Switzerland have different legal and economic postulates, the medical examination has to be adapted to the different premises. The definition and description of this special type of "medical clearance for missions abroad" is supplemented by recommendations for definitions of clients who should undergo such an investigation and the professionals who should perform this type of investigation. Additionally, results of this type of medical clearance are defined and prophylactic aspects in terms of pre-travel advice are mentioned.

  12. Adalimumab Dose Tapering in Psoriasis: Predictive Factors for Maintenance of Complete Clearance.

    Science.gov (United States)

    Hansel, Katharina; Bianchi, Leonardo; Lanza, Francesco; Bini, Vittorio; Stingeni, Luca

    2017-03-10

    Psoriasis can be managed successfully with long-term biologics. Real-life clinical practice may require dose tapering as a therapeutic option to reduce the risk of drug-exposure and to increase cost-effectiveness. The responsiveness to extended intervals between adalimumab doses and the possible predictive factors of maintenance of complete clearance were studied in a retrospective 7-year single-centre analysis. Thirty patients who achieved complete clearance with adalimumab underwent dose tapering, progressively extending between-dose intervals (to 21-28 days). Sixty percent of subjects (group A) maintained complete clearance, whereas 40.0% (group B) relapsed and were switched back to the standard dosage to re-achieve complete clearance. Body mass index (BMI) and time to achieve Psoriasis Area Severity Index (PASI-100) with adalimumab standard treatment before dose tapering were significantly lower in group A than in group B (multi-variate Cox regression: p < 0.05, Kaplan-Meier analysis: p < 0.001, respectively). This study suggests that patients with lower BMI and shorter time to achieve PASI-100 with adalimumab standard dose were significantly more likely to be candidates for dose tapering.

  13. Lithium clearance method and the renal response to low-dose dopamine in man

    DEFF Research Database (Denmark)

    Olsen, N V; Olsen, M H; Fogh-Andersen, N

    1993-01-01

    .00 hours on three different occasions. After an overnight fast, the subjects were water-loaded and clearance studies were started at 09.00 hours with a 1h baseline period and three 1h periods during dopamine infusion. 2. Baseline sodium clearance with placebo was 0.65 +/- 0.35 ml/min, but with lithium......-induced changes in effective renal plasma flow, glomerular filtration rate or osmolal clearance. Neither lithium nor dopamine influenced plasma concentrations of renin, aldosterone or atrial natriuretic peptide. 4. In conclusion, single test doses of lithium, as normally used in lithium clearance studies......1. The effect of a single dose of lithium on renal function before and during intravenous infusion of dopamine (3 micrograms min-1 kg-1) was investigated in 12 healthy males. In a double-blind and randomized design, 450mg or 600mg of lithium carbonate or placebo was administered orally at 22...

  14. Lithium clearance method and the renal response to low-dose dopamine in man

    DEFF Research Database (Denmark)

    Olsen, Niels Vidiendal; Olsen, M H; Fogh-Andersen, N

    1993-01-01

    .00 hours on three different occasions. After an overnight fast, the subjects were water-loaded and clearance studies were started at 09.00 hours with a 1h baseline period and three 1h periods during dopamine infusion. 2. Baseline sodium clearance with placebo was 0.65 +/- 0.35 ml/min, but with lithium...... in effective renal plasma flow, glomerular filtration rate or osmolal clearance. Neither lithium nor dopamine influenced plasma concentrations of renin, aldosterone or atrial natriuretic peptide. 4. In conclusion, single test doses of lithium, as normally used in lithium clearance studies, increase baseline......1. The effect of a single dose of lithium on renal function before and during intravenous infusion of dopamine (3 micrograms min-1 kg-1) was investigated in 12 healthy males. In a double-blind and randomized design, 450mg or 600mg of lithium carbonate or placebo was administered orally at 22...

  15. Turbine blade tip clearance measurement using a skewed dual-beam fiber optic sensor

    Science.gov (United States)

    Ye, De-chao; Duan, Fa-jie; Guo, Hao-tian; Li, Yangzong; Wang, Kai

    2012-08-01

    Optimization and active control of the tip clearance of turbine blades has been identified as a key to improve fuel efficiency, reduce emission, and increase service life of the engine. However, reliable and real-time tip clearance measurement is difficult due to the adverse environmental conditions that are typically found in a turbine. We describe a dual-beam fiber optic measurement system that can measure the tip timing and tip clearance simultaneously. Because the tip timing information is used to calculate the tip clearance, the method is insensitive to the signal intensity variation caused by fluctuations in environmental conditions such as light source instability, contamination, and blade tip imperfection. The system was calibrated and tested using experimental rotors. The test results indicated a high resolution of 4.5 μm and measurement accuracy of ±20 μm over the rotation speed range of 2000 to 10,000 rpm.

  16. Radioactive clearance discharge of effluent from nuclear and radiation facilities

    International Nuclear Information System (INIS)

    Liu Xinhua; Xu Chunyan

    2013-01-01

    On the basis of the basic concepts of radiation safety management system exemption, exclusion and clearance, we expound that the general industrial gaseous and liquid effluent discharges are exempted or excluded, gaseous and liquid effluent discharged from nuclear and radiation facilities are clearance, and non-radioactive. The main purpose of this paper is to clarify the concepts, reach a consensus that the gaseous and liquid effluent discharged from nuclear and radiation facilities are non-radioactive and have no hazard to human health and natural environment. (authors)

  17. Effects and outcome of Tamsulosin more than just stone clearance after extracorporeal shock wave lithotripsy for renal calculi

    International Nuclear Information System (INIS)

    Qadri, S. S. U.; Khalid, S. E.; Mahmud, S. M.

    2014-01-01

    Objective: To determine the effect of Tamsulosin, as adjunctive medical therapy after Extracorporeal Shock Wave Lithotripsy for renal stones on rate of stone clearance, clearance time, pain intensity during stone clearance, steinstrasse formation and auxiliary surgical intervention required. Method: A prospective randomized controlled study was carried out in 120 patients who underwent ESWL for renal stones of 0.5-2.0 cm. They were randomized into study and control group in which Tamsulosin 0.4mg/day was given in former as an adjunctive medical therapy. All patients underwent ESWL every 2 weeks until complete stone clearance for 8 weeks. The parameters assessed were stone clearance, clearance time, pain intensity and effect on steinstrasse. Results: Of the 120 patients 60 were in each group. The stone clearance rate was greater in study than in control group, 58(96.7%) vs. 48(80%) respectively, (p<0.004). The mean stone clearance time was observed earlier in study group as compared to control group with significant statistical difference in stone size between 0.6-1.5 cm. The mean intensity of pain patients experienced according to Visual analogue scale (VAS) was significantly less in study group (p<0.002). The rate of steinstrasse formation was observed to be higher in control than in study group 15(25%) vs 6(10%) respectively(p<0.003), while its spontaneous clearance was higher in study group than in control group 83.3% vs 33.3% (p<0.03). Conclusion: Tamsulosin significantly increases stone clearance after shock wave lithotripsy for renal stones. It also appeared to facilitate earlier stone clearance, reduces severity of pain, reduces the incidence of steinstrasse formation and tends to facilitate its spontaneous clearance. (author)

  18. Development of a Novel System to Measure a Clearance of a Passenger Platform

    Science.gov (United States)

    Shimizu, M.; Oizumi, J.; Matsuoka, R.; Takeda, H.; Okukura, H.; Ooya, A.; Koike, A.

    2016-06-01

    Clearances of a passenger platform at a railway station should be appropriately maintained for safety of both trains and passengers. In most Japanese railways clearances between a platform and a train car is measured precisely once or twice a year. Because current measurement systems operate on a track, the closure of the track is unavoidable. Since the procedure of the closure of a track is time-consuming and bothersome, we decided to develop a new system to measure clearances without the closure of a track. A new system is required to work on a platform and the required measurement accuracy is less than several millimetres. We have adopted a 3D laser scanner and stop-and-go operation for a new system. The current systems on a track measure clearances continuously at walking speed, while our system on a platform measures clearances at approximately ten metres intervals. The scanner controlled by a PC acquires a set of point data at each measuring station. Edge points of the platform, top and side points of two rails are detected from the acquired point data. Finally clearances of the platform are calculated by using the detected feature points of the platform and the rails. The results of an experiment using a prototype of our system show that the measurement accuracy by our system would be satisfactory, but our system would take more time than the current systems. Since our system requires no closure of a track, we conclude that our system would be convenient and effective.

  19. Effects of a Nonuniform Tip Clearance Profile on the Performance and Flow Field in a Centrifugal Compressor

    Directory of Open Access Journals (Sweden)

    Yohan Jung

    2012-01-01

    Full Text Available This paper presents a numerical investigation of the effects of a nonuniform tip clearance profile on the performance and flow field in a centrifugal compressor with a vaneless diffuser. This study focuses in particular on the magnitude and location of the wake. Six impellers with different tip clearance profiles were tested in the flow simulations. The accuracy of the numerical simulations was assessed by comparing the experimental data with the computational results for a system characterized by the original tip clearance. Although the performance improved for low tip clearances, a low tip clearance at the trailing edge improved the compressor performance more significantly than a low tip clearance at the leading edge. The flow field calculated for a system characterized by a low tip clearance at the trailing edge produced a more uniform velocity distribution both in the circumferential and in the axial directions at the impeller exit because the wake magnitude was reduced. As a consequence, this impeller provided a better potential for diffusion processes inside a vaneless diffuser.

  20. 78 FR 69643 - Proposed Information Collection; Comment Request; Generic Clearance for Customer Satisfaction...

    Science.gov (United States)

    2013-11-20

    ... Clearance for Customer Satisfaction Research AGENCY: U.S. Census Bureau, Commerce. ACTION: Notice. SUMMARY... requesting an extension of the generic clearance to conduct customer satisfaction research which may be in... feedback from its various customer satisfaction research efforts. Each research design is reviewed for...

  1. 76 FR 63301 - Agency Information Collection Activities: Proposed Collection; Comment Request; Generic Clearance...

    Science.gov (United States)

    2011-10-12

    ... requirements or power calculations that justify the proposed sample size, the expected response rate, methods... Collection; Comment Request; Generic Clearance for the Collection of Qualitative Feedback on Agency Service... Clearance for the Collection of Qualitative Feedback on Agency Service Delivery'' to OMB for approval under...

  2. 76 FR 15027 - Agency Information Collection Activities: Proposed Collection; Comment Request; Generic Clearance...

    Science.gov (United States)

    2011-03-18

    ... clustering), the precision requirements or power calculations that justify the proposed sample size, the...; Comment Request; Generic Clearance for the Collection of Qualitative Feedback on Agency Service Delivery... Clearance for the Collection of Qualitative Feedback on Agency Service Delivery'' to OMB for approval under...

  3. Railway clearance intrusion detection method with binocular stereo vision

    Science.gov (United States)

    Zhou, Xingfang; Guo, Baoqing; Wei, Wei

    2018-03-01

    In the stage of railway construction and operation, objects intruding railway clearance greatly threaten the safety of railway operation. Real-time intrusion detection is of great importance. For the shortcomings of depth insensitive and shadow interference of single image method, an intrusion detection method with binocular stereo vision is proposed to reconstruct the 3D scene for locating the objects and judging clearance intrusion. The binocular cameras are calibrated with Zhang Zhengyou's method. In order to improve the 3D reconstruction speed, a suspicious region is firstly determined by background difference method of a single camera's image sequences. The image rectification, stereo matching and 3D reconstruction process are only executed when there is a suspicious region. A transformation matrix from Camera Coordinate System(CCS) to Track Coordinate System(TCS) is computed with gauge constant and used to transfer the 3D point clouds into the TCS, then the 3D point clouds are used to calculate the object position and intrusion in TCS. The experiments in railway scene show that the position precision is better than 10mm. It is an effective way for clearance intrusion detection and can satisfy the requirement of railway application.

  4. Losses and blade tip clearance for a centrifugal compressor

    Directory of Open Access Journals (Sweden)

    Oana DUMITRESCU

    2018-06-01

    Full Text Available The present paper presents the numerical analysis for a transonic centrifugal compressor using steady state CFD. The blade tip clearance effect over the position of shock waves, tip losses and the performances of the impeller are studied. Numerical simulations have been performed using RANS modelling, with the k-omega SST turbulence model (Shear Stress Transport. Eight cases were taken into consideration for the impeller with the following blade tip clearances values: 0 mm, 0.1 mm, 0.3 mm, 0.4 mm, 0.5mm, 0.7 mm, 1 mm, 2 mm, at the same operating conditions. For the entire stage only seven cases were studied, without the value for 0.1 mm because of its abnormal behaviour, as can be seen in the case of the impeller simulations. Results showed that the position of the shock wave does not change with the increase of the tip clearance. Aerodynamic losses due to shock wave, secondary flow and turbulence can be seen in the polytropic efficiency of the centrifugal impeller and the difference between the two extreme cases is about 3.2 %.

  5. The provision of clearances accuracy in piston - cylinder mating

    Science.gov (United States)

    Glukhov, V. I.; Shalay, V. V.

    2017-08-01

    The paper is aimed at increasing the quality of the pumping equipment in oil and gas industry. The main purpose of the study is to stabilize maximum values of productivity and durability of the pumping equipment based on the selective assembly of the cylinder-piston kinematic mating by optimization criterion. It is shown that the minimum clearance in the piston-cylinder mating is formed by maximum material dimensions. It is proved that maximum material dimensions are characterized by their own laws of distribution within the tolerance limits for the diameters of the cylinder internal mirror and the outer cylindrical surface of the piston. At that, their dispersion zones should be divided into size groups with a group tolerance equal to half the tolerance for the minimum clearance. The techniques for measuring the material dimensions - the smallest cylinder diameter and the largest piston diameter according to the envelope condition - are developed for sorting them into size groups. Reliable control of the dimensions precision ensures optimal minimum clearances of the piston-cylinder mating in all the size groups of the pumping equipment, necessary for increasing the equipment productivity and durability during the production, operation and repair processes.

  6. Brain-wide pathway for waste clearance captured by contrast-enhanced MRI.

    Science.gov (United States)

    Iliff, Jeffrey J; Lee, Hedok; Yu, Mei; Feng, Tian; Logan, Jean; Nedergaard, Maiken; Benveniste, Helene

    2013-03-01

    The glymphatic system is a recently defined brain-wide paravascular pathway for cerebrospinal fluid (CSF) and interstitial fluid (ISF) exchange that facilitates efficient clearance of solutes and waste from the brain. CSF enters the brain along para-arterial channels to exchange with ISF, which is in turn cleared from the brain along para-venous pathways. Because soluble amyloid β clearance depends on glymphatic pathway function, we proposed that failure of this clearance system contributes to amyloid plaque deposition and Alzheimer's disease progression. Here we provide proof of concept that glymphatic pathway function can be measured using a clinically relevant imaging technique. Dynamic contrast-enhanced MRI was used to visualize CSF-ISF exchange across the rat brain following intrathecal paramagnetic contrast agent administration. Key features of glymphatic pathway function were confirmed, including visualization of para-arterial CSF influx and molecular size-dependent CSF-ISF exchange. Whole-brain imaging allowed the identification of two key influx nodes at the pituitary and pineal gland recesses, while dynamic MRI permitted the definition of simple kinetic parameters to characterize glymphatic CSF-ISF exchange and solute clearance from the brain. We propose that this MRI approach may provide the basis for a wholly new strategy to evaluate Alzheimer's disease susceptibility and progression in the live human brain.

  7. Areva excellent business volume: backlog as of december 31, 2008: + 21.1% to 48.2 billion euros. 2008 revenue: + 10.4% to 13.2 billion euros; Areva excellent niveau d'activite: carnet de commandes au 31/12/2008: + 21,1% a 48,2 Mds d'euros. Chiffre d'affaires de l'exercice 2008: + 10,4% a 13,2 Mds d'euros

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2009-07-01

    AREVA's backlog stood at 48.2 billion euros as of December 31, 2008, for 21.1% growth year-on-year, including 21.8% growth in Nuclear and 16.5% growth in Transmission and Distribution. The Nuclear backlog came to 42.5 billion euros at December 31, 2008. The Transmission and Distribution backlog came to 5.7 billion euros at year-end. The group recognized revenue of 13.2 billion euros in 2008, for year-on-year growth of 10.4% (+9.8% like-for-like). Revenue outside France was up 10.5% to 9.5 billion euros, representing 72% of total revenue. Revenue was up 6.5% in the Nuclear businesses (up 6.3% LFL), with strong performance in the Reactors and Services division (+10.9% LFL) and the Front End division (+7.2% LFL). The Transmission and Distribution division recorded growth of 17% (+15.8% LFL). Revenue for the fourth quarter of 2008 rose to 4.1 billion euros, up 5.2% (+1.6% LFL) from that of the fourth quarter of 2007. Revenue for the Front End division rose to 3.363 billion euros in 2008, up 7.1% over 2007 (+7.2% LFL). Foreign exchange (currency translations) had a negative impact of 53 million euros. Revenue for the Reactors and Services division rose to 3.037 billion euros, up 11.8% over 2007 (+10.9% LFL). Foreign exchange (currency translations) had a negative impact of 47 million euros. Revenue for the Back End division came to 1.692 billion euros, a drop of 2.7% (-2.5% LFL). Foreign exchange (currency translations) had a negative impact of 3.5 million euros. Revenue for the Transmission and Distribution division rose to 5.065 billion euros in 2008, up 17.0% (+15.8% LFL)

  8. Residual kidney function after donor nephrectomy. Assessment by 99mTc-MAG3-Clearance

    International Nuclear Information System (INIS)

    Hamscho, N.; Doebert, N.; Menzel, C.; Berner, U.; Zaplatnikov, K.; Gruenwald, F.; Wilhelm, A.; Gossmann, J.; Scheuermann, E.H.

    2005-01-01

    Aim: We evaluated the long-term residual renal function after donor nephrectomy using 99m Tc-mercaptoacetyltriglycin (MAG3)-clearance. Donors, methods: Altogether 49 kidney donors were examined using 99m Tc-MAG3-clearance after nephrectomy for donation to a relative (m:f=11.38; age 55±27 years). The donors were examined 16±8 years postoperatively (1.5-26 years). 42 donors (86%) showed normal creatinine values, whereas the other seven (14%) exhibited slightly elevated levels. 20 donors were examined pre- and postoperatively and compared intraindividually. The kidney function was compared to the age adapted normal values of healthy persons with two kidneys (67-133% of age related mean). Results: After nephrectomy all donors showed a normal perfusion, good secretion, merely physiological intrarenal transit and a normal elimination from the kidneys. The 99m Tc-MAG3-clearance was 69±15% of the normal mean value of healthy carriers of two kidneys regardless of the gender. 20 donors with a preoperative examination showed a significantly reduced total renal function from 84±15% of the mean normal value preoperatively to 60±15% postoperatively (p 99m Tc-MAG3-clearance measured prior to nephrectomy and the clearance levels after nephrectomy. Also, no correlation between the preoperative 99m Tc-MAG3-clearance and the postoperative serum creatinine values could be observed. Althogether, 22% of the donors (11/49) developed arterial hypertension 10±8 years after donation (1-23 years). This corresponds to the normal age prevalence of hypertension in the carriers of two kidneys. Three donors suffered from arterial hypertension prior to the operation. Conclusion: Kidney donors with normal or slightly elevated creatinine values postoperatively show a 99m Tc-MAG3 clearance value of 69% of the mean value of healthy carriers of two kidneys. This may serve as a reference value for healthy carriers of one kidney. In our study we demonstrated a good compensation of the contralateral

  9. Demonstration of a dynamic clearance seal in a rotating test facility.

    OpenAIRE

    Messenger, Andrew; Williams, Richard; Ingram, Grant; Hogg, Simon; Tibos, Stacie; Seaton, Jon; Charnley, Bernard

    2017-01-01

    The successful demonstration of the “Aerostatic Seal” in a half scale rotating facility is described in this paper. The Aerostatic seal is a novel dynamic clearance seal specifically designed for steam turbine secondary gas path applications. The seal responds to radial rotor excursions, so a reduced clearance can be maintained compared to conventional labyrinth seal without damage to the seal. This enables increased turbine performance through reduced leakage and increased tolerance of turbi...

  10. Intra-operative colloid administration increases the clearance of a post-operative fluid load

    DEFF Research Database (Denmark)

    Borup, Tine; Hahn, Robert; Holte, K

    2009-01-01

    using volume kinetics based on the plasma dilution alone. The pre-operative plasma clearance was compared with the post-operative plasma clearance and patients served as their own control. RESULTS: The urinary excretion averaged 350 ml for the pre-operative infusion and 612 ml post-operatively, which...

  11. 76 FR 20967 - Agency Information Collection Activities: Proposed Collection; Comment Request; Generic Clearance...

    Science.gov (United States)

    2011-04-14

    ... requirements or power calculations that justify the proposed sample size, the expected response rate, methods... Request; Generic Clearance for the Collection of Qualitative Feedback on Agency Service Delivery AGENCY: U... Clearance for the Collection of Qualitative Feedback on Agency Service Delivery'' to OMB for approval under...

  12. Clearance rate of Mytilus edulis (L.) as a function of current velocity and mussel aggregation

    DEFF Research Database (Denmark)

    Nielsen, Pernille; Vismann, Bent

    2014-01-01

    by current velocities up to 1.4 m/sec, whereas experiments with 3 mussels showed that clearance of the mussels decreased progressively at current velocities greater than 0.2 m/sec, and reached 0 L/h per individual at current velocities greater than 0.6 m/sec. The constant feeding at all current velocities......The aim of the current study was to investigate the effect of water current velocities on the clearance rate of Mytilus edulis when different numbers of mussels were used in the experiments. An automatic setup, which controlled and monitored the algal concentration continually, was used to measure...... the effect of increasing current velocity (0.05-1.4 m/sec) on the M. edulis clearance rate. Clearance rate measurements were performed under constant food concentrations of 3,000 cells/mL of Rhodomonas salina on either 3 mussels or 20 mussels. We found that the clearance rate of 20 mussels was unaffected...

  13. Effect of increased surface hydrophobicity via drug conjugation on the clearance of inhaled PEGylated polylysine dendrimers.

    Science.gov (United States)

    Haque, Shadabul; McLeod, Victoria M; Jones, Seth; Fung, Sandy; Whittaker, Michael; McIntosh, Michelle; Pouton, Colin; Owen, David J; Porter, Christopher J H; Kaminskas, Lisa M

    2017-10-01

    PEGylated polylysine dendrimers are attractive and well tolerated inhalable drug delivery platforms that have the potential to control the release, absorption kinetics and lung retention time of conjugated drugs. The clinical application of these systems though, would likely require partial substitution of surface PEG groups with drug molecules that are anticipated to alter their lung clearance kinetics and clearance pathways. In the current study, we therefore evaluated the impact of increased surface hydrophobicity via substitution of 50% surface PEG groups with a model hydrophobic drug (α-carboxyl OtButylated methotrexate) on the lung clearance of a Generation 5 PEGylated polylysine dendrimer in rats. PEG substitution with OtBu-methotrexate accelerated lung clearance of the dendrimer by increasing polylysine scaffold catabolism, improving systemic absorption of the intact dendrimer and low molecular weight products of scaffold catabolism, and enhancing mucociliary clearance. These results suggest that the conjugation of hydrophobic drug on the surface of a PEGylated dendrimer is likely to accelerate lung clearance when compared to a fully PEGylated dendrimer. Crown Copyright © 2017. Published by Elsevier B.V. All rights reserved.

  14. Using radioaerosols to monitor physiotherapy-enhanced mucus clearance at different levels of the bronchial tree

    International Nuclear Information System (INIS)

    Hasani, A.; Pavia, D.; Clarke, S.W.; Agnew, J.E.

    1993-01-01

    Patients with airways obstruction often find it difficult to clear excess lung secretions. Frequent coughing can clear the larger airways but may itself further damage the airways ciliated epithelium. Various physiotherapy regimes have been proposed yet objective evidence of their efficacy is sparse. Deposited aerosol particles - with an appropriate label for gamma imaging - can track clearance from different lung regions. Published reports have however tended to be equivocal in respect of clearance from the more distal conducting airways. Questions also arise as to coordination of transport rates at different levels of the bronchial tree. We therefore sought to re-assess requirements for effective analysis of physiotherapy-enhanced clearance to yield data on both peripheral and central airways clearance. (author)

  15. Using radioaerosols to monitor physiotherapy-enhanced mucus clearance at different levels of the bronchial tree

    Energy Technology Data Exchange (ETDEWEB)

    Hasani, A.; Pavia, D.; Clarke, S.W.; Agnew, J.E. (Royal Free Hospital, London (United Kingdom))

    1993-01-01

    Patients with airways obstruction often find it difficult to clear excess lung secretions. Frequent coughing can clear the larger airways but may itself further damage the airways ciliated epithelium. Various physiotherapy regimes have been proposed yet objective evidence of their efficacy is sparse. Deposited aerosol particles - with an appropriate label for gamma imaging - can track clearance from different lung regions. Published reports have however tended to be equivocal in respect of clearance from the more distal conducting airways. Questions also arise as to coordination of transport rates at different levels of the bronchial tree. We therefore sought to re-assess requirements for effective analysis of physiotherapy-enhanced clearance to yield data on both peripheral and central airways clearance. (author).

  16. Binding and clearance of Tc-99m pyrophosphate from the lungs of smokers and nonsmokers

    International Nuclear Information System (INIS)

    Isitman, A.T.; Effros, R.; Collier, B.D.; Palmer, D.W.; Krasnow, A.Z.; Hellman, R.S.; Hacker, A.; Berger, C.; Trembath, L.

    1990-01-01

    Both acute and chronic lung disorders that affect the alveolar epithelium increase the rate at which aerosolized Tc-99 m DTPA is cleared from the lungs. Transalveolar clearance of Tc-99 DTPA has been used to detect lung injury, but- because smokers have a much faster clearance rate of Tc-99m DTPA-this examination has been limited primarily to nonsmokers. The purpose of this paper is to determine if the clearance of a larger molecule, Tc-99m PYP (molecular weight by ultrafiltration between 1.000 and 3,000 daltons), is also accelerated by smoking. Clearances of each indicator were studies for 6 hours in eight normal nonsmoking subjects and seven (otherwise normal smokers)

  17. Four hour creatinine clearance is better than plasma creatinine for monitoring renal function in critically ill patients

    Science.gov (United States)

    2012-01-01

    Introduction Acute kidney injury (AKI) diagnosis is based on an increase in plasma creatinine, which is a slowly changing surrogate of decreased glomerular filtration rate. We investigated whether serial creatinine clearance, a direct measure of the glomerular filtration rate, provided more timely and accurate information on renal function than serial plasma creatinine in critically ill patients. Methods Serial plasma creatinine and 4-hour creatinine clearance were measured 12-hourly for 24 hours and then daily in 484 patients. AKI was defined either as > 50% increase in plasma creatinine from baseline, or > 33.3% decrease in creatinine clearance. The diagnostic and predictive performance of the two AKI definitions were compared. Results Creatinine clearance decrease diagnosed AKI in 24% of those not diagnosed by plasma creatinine increase on entry. These patients entered the ICU sooner after insult than those diagnosed with AKI by plasma creatinine elevation (P = 0.0041). Mortality and dialysis requirement increased with the change in creatinine clearance-acute kidney injury severity class (P = 0.0021). Amongst patients with plasma creatinine creatinine clearance improved the prediction of AKI considerably (Net Reclassification Improvement 83%, Integrated Discrimination Improvement 0.29). On-entry, creatinine clearance associated with AKI severity and duration (P 33.3% decrease in creatinine clearance over the first 12 hours was associated with a 2.0-fold increased relative risk of dialysis or death. Conclusions Repeated 4-hour creatinine clearance measurements in critically ill patients allow earlier detection of AKI, as well as progression and recovery compared to plasma creatinine. Trial Registration Australian New Zealand Clinical Trials Registry ACTRN012606000032550. PMID:22713519

  18. Identification of Clearance and Contact Stiffness in a Simplified Barrel-Cradle Structure of Artillery System

    Directory of Open Access Journals (Sweden)

    Bing Li

    2015-02-01

    Full Text Available In gun barrel-cradle structure, the presence of clearance usually changes the dynamic response of muzzle and results in shooting dispersion (under continuous firing condition. The parameter estimation of such clearance nonlinear system is the prerequisite for establishing quantitative relation between the clearance and muzzle disturbance. In this paper, the restoring force surface (RFS method and the nonlinear identification through feedback of outputs (NIFO method are first combined for parameter identification in a simplified barrel-cradle structure. With the RFS method, clearance value can be obtained by analyzing the restoring force plot. Then the contact stiffness can be identified by using NIFO method. This identification process is verified in a single-degree-of-freedom (SDOF system with clearance. To adapt to the rigid-flexible coupled beam system with clearances which is simplified from the barrel-cradle structure, a modification for the combined method mentioned above is proposed. The core idea of the modification is reducing the continuous system to multiple-degree-of-freedom (MDOF system to reserve the nonlinear characteristics through modal transformation matrix. The advantage of this transformation is that the linear parts of the MDOF systems are decoupled, which greatly reduces the difficulty of identification. The simulation results have shown the effectiveness of current method.

  19. Comparative study of conventional PAH and inulin clearance and slope clearance of 131I-o-hippuric acid and 51Cr-EDTA

    International Nuclear Information System (INIS)

    Berghaeuser, H.

    1981-01-01

    ''Classic'' PAH and inulin clearance were determined in 81 patients with renal anomalies or renal diseases of different genesis and severity. In addition, radioisotope nephrography was carried out after administration of I-131-o-hippuric acid, followed by administration of Cr-51-EDTA. The activity decrease was recorded by a sensor located over the patient's right shoulder; the activities of a serum sample and of the urine excreted after 21 or 31 min were measured, and the findings were compared with those of the classic method. The clearance data calculated on the basis of the soulder measurements were hardly compatible with those of the conventional method in the case of 131 I-o-hippuric acid (r=0.54) and totally incompatible in the case of 51 Cr-EDTA. This means that the method described by Oberhausen is the only accurate method available for a quantitative assessment of the renal function on the basis of measurements of the activity decrease in the body. The activity of urine excreted after 31 min ( 131 I-hippuric acid:r=0.992, 51 Cr-EDTA:r=0.79) is a sufficiently accurate parameter although it is inaccurate at PAH clearance, values > 130 ml/min and inulin clearance values > 30 ml/min. Of the many parameters of radioisotope nephrogram curves, in the case of 131 I-o-hippuric acid only the parameters related to the ascent between 48 and 120 sec or to the secant ascent yield sufficient quantitative information for certain functional regions (r=0.9 resp. r=0.93). In the case of 51 Cr-EDTA, semiquantitative information on the renal function can be obtained by constructing secants on the nephrogram curves (r=0.7 resp. r=0.72). Here as in the case of 131 I-hippuric acid, the contribution of each kidney can be determined individually from the functional analysis of both kidneys. (orig.) [de

  20. Collaboration in Research and Engineering for Advanced Technology.

    Energy Technology Data Exchange (ETDEWEB)

    Vrieling, P. Douglas [Sandia National Lab. (SNL-CA), Livermore, CA (United States)

    2016-01-01

    SNL/CA proposes the Collaboration in Research and Engineering for Advanced Technology and Education (CREATE) facility to support customer-driven national security mission requirements while demonstrating a fiscally responsible approach to cost-control. SNL/CA realizes that due to the current backlog of capital projects in NNSA that following the normal Line Item process to procure capital funding is unlikely and therefore SNL/CA will be looking at all options including Alternative Financing.

  1. Control of internal packing seal clearances considering for shaft behavior during steam turbine operation

    Energy Technology Data Exchange (ETDEWEB)

    Pack, Min Sik; Lee, Si Yeon; Choi, Sung Choul; Lee, Jae Geun [Korea Plant Service and Engineering Co., Ltd., Seongnam (Korea, Republic of); Yang, Bo Suk [Pukyong National Univ., Busan (Korea, Republic of)

    2004-07-01

    This paper presents the characteristics of internal clearances for the interstage of blades and shaft gland seals on the steam turbine which are installed in tandem compound. Internal clearances was changed when the rotor turned in the cylindrical sleeve bearing due to the generation of oil film wedge. This presented concern is very useful to prevent the rubbing damage of seal edge between the fixed and moving parts in steam turbine due to the misalignment at the rotating and stationary parts. This method is applied for the unbalanced clearances distribution to the left and right sides in the turbine casing. A considerable amount of unbalanced clearances distribution trend is determined according to the rotating speed of rotor, size and type of journal bearing, oil viscosity, surface roughness of bearing and shaft, oil temperature, oil pressure and bearing load.

  2. Effects of cigarette smoking on I-123 IMP clearance from the lung

    International Nuclear Information System (INIS)

    Katoh, Kunihiko; Takahashi, Tsuneo

    1990-01-01

    N-isopropyl-p-I-123-iodoamphetamine (I-123 IMP), originally developed as a brain scanning agent, is also taken up by the lung. To evaluate the cigarette smoking on the uptake of IMP by the lung, we studied I-123 IMP clearance from the lung on 14 volunteers; 5 non-smokers and 9 smokers. After the injection of 111 MBq (3mCi) of I-123 IMP into the medial cubital vein, the time-activity curve for 60 minutes and the regional activity using 1 frame per minute and a 64 x 64 matrix was obtained. I-123 IMP clearance curve was described as follows: C(t)=A 1 e -k1t +A 2 e -k2t (A 1 , A 2 : intercepts, and k 1 , k 2 : slopes of the exponential components). I-123 IMP clearance was delayed in smokers, and k 2 was smaller in smokers. Also a significant correlations between k 1 , k 2 , and the number of cigarettes smoked per day were found. In conclusion, this study suggests that the delayed clearance and retention of I-123 IMP in the lung indicate the lung metabolic disorders due to cigarette smoking. (author)

  3. Effect of Guide Vane Clearance Gap on Francis Turbine Performance

    Directory of Open Access Journals (Sweden)

    Ravi Koirala

    2016-04-01

    Full Text Available Francis turbine guide vanes have pivoted support with external control mechanism, for conversion of pressure to kinetic energy and to direct them to runner vanes. This movement along the support is dependent on variation of load and flow (operating conditions. Small clearance gaps between facing plates and the upper and lower guide vane tips are available to aid this movement, through which leakage flow occurs. This secondary flow disturbs the main flow stream, resulting performance loss. Additionally, these increased horseshoe vortex, in presence of sand, when crosses through the gaps, both the surfaces are eroded. This causes further serious effect on performance and structural property by increasing gaps. This paper discusses the observation of the severity in hydropower plants and effect of clearance gaps on general performance of the Francis turbine through computational methods. It also relates the primary result with the empirical relation for leakage flow prediction. Additionally, a possible method to computationally estimate thickness depletion has also been presented. With increasing clearance gap, leakage increases, which lowers energy conversion and turbine efficiency along with larger secondary vortex.

  4. Impairment of aminopyrine clearance in aspirin-damaged canine gastric mucosa

    International Nuclear Information System (INIS)

    Miller, T.A.; Henagan, J.M.; Loy, T.M.

    1983-01-01

    Using an in vivo canine chambered stomach preparation, the clearance of [ 14 C]aminopyrine across mucosa when intravenously infused and the back-diffusion of this substance from gastric lumen to mucosa when topically applied to gastric epithelium were evaluated in aspirin-damaged gastric epithelium. In mucosa damaged by either 20 mM or 40 mM aspirin, the recovery of [ 14 C]aminopyrine, when topically mixed with acid (pH . 1.1) perfusate solution, was not significantly different from nondamaged control mucosa. In addition, the degree of ''trapping'' of this substance from back-diffusion was not different in damaged mucosa from that observed in nondamaged epithelium. In contrast, when [ 14 C]aminopyrine was intravenously infused, its clearance was significantly impaired in aspirin-damaged mucosa when compared with control studies, as evidenced by the increased ''trapping'' of this substance in injured epithelium. These findings indicate that movement of aminopyrine from plasma to gastric lumen is impaired in damaged epithelium, making the aminopyrine clearance technique an unreliable method to accurately measure absolute gastric blood flow in this experimental setting

  5. Numerical investigation of tip clearance cavitation in Kaplan runners

    Science.gov (United States)

    Nikiforova, K.; Semenov, G.; Kuznetsov, I.; Spiridonov, E.

    2016-11-01

    There is a gap between the Kaplan runner blade and the shroud that makes for a special kind of cavitation: cavitation in the tip leakage flow. Two types of cavitation caused by the presence of clearance gap are known: tip vortex cavitation that appears at the core of the rolled up vortex on the blade suction side and tip clearance cavitation that appears precisely in the gap between the blade tip edge and the shroud. In the context of this work numerical investigation of the model Kaplan runner has been performed taking into account variable tip clearance for several cavitation regimes. The focus is put on investigation of structure and origination of mechanism of cavitation in the tip leakage flow. Calculations have been performed with the help of 3-D unsteady numerical model for two-phase medium. Modeling of turbulent flow in this work has been carried out using full equations of Navier-Stokes averaged by Reynolds with correction for streamline curvature and system rotation. For description of this medium (liquid-vapor) simplification of Euler approach is used; it is based on the model of interpenetrating continuums, within the bounds of this two- phase medium considered as a quasi-homogeneous mixture with the common velocity field and continuous distribution of density for both phases. As a result, engineering techniques for calculation of cavitation conditioned by existence of tip clearance in model turbine runner have been developed. The detailed visualization of the flow was carried out and vortex structure on the suction side of the blade was reproduced. The range of frequency with maximum value of pulsation was assigned and maximum energy frequency was defined; it is based on spectral analysis of the obtained data. Comparison between numerical computation results and experimental data has been also performed. The location of cavitation zone has a good agreement with experiment for all analyzed regimes.

  6. 14 CFR 99.17 - Deviation from flight plans and ATC clearances and instructions.

    Science.gov (United States)

    2010-01-01

    ... 14 Aeronautics and Space 2 2010-01-01 2010-01-01 false Deviation from flight plans and ATC clearances and instructions. 99.17 Section 99.17 Aeronautics and Space FEDERAL AVIATION ADMINISTRATION... TRAFFIC General § 99.17 Deviation from flight plans and ATC clearances and instructions. (a) No pilot may...

  7. Frequency of stone clearance after extracorporeal shockwave ...

    African Journals Online (AJOL)

    Objective: To determine the rate of stone clearance after extracorporeal shockwave lithotripsy (ESWL) for renal stones in adult patients with renal insufficiency. Subjects and methods: This is a cross-sectional descriptive study of 117 adult patients who underwent ESWL. The indications for ESWL were determined by the ...

  8. Correlates of spontaneous clearance of hepatitis C virus in a Danish human immunodeficiency virus type 1 cohort

    DEFF Research Database (Denmark)

    Clausen, Louise Nygaard; Weis, Nina; Schønning, Kristian

    2011-01-01

    ) 18-28) had cleared their HCV infection and 251 (77%; 95% CI 72-82) had a chronic infection. The clearance rate in HBsAg-positive individuals was 65%. Being female, HBsAg-positive, or belonging to HIV exposure groups IDU and MSM predicted higher HCV clearance rates (adjusted odds ratio (aOR) 1.8, 95......% CI 1-3.2; aOR 7.6, 95% CI 2.7-21; aOR 5.2, 1.2-23.5; and aOR 10.2, 95% CI 1.8-58, respectively). Race, acquired immunodeficiency syndrome (AIDS), and antiretroviral therapy were not associated with HCV clearance. Conclusions: The HCV clearance rate in this HIV-1 cohort was 23%. MSM and IDUs may have......Abstract Background: Around a quarter of individuals infected with hepatitis C virus (HCV) are spontaneously able to clear the virus. Correlates of spontaneous HCV clearance are not well established and the aim of this study was to characterize factors associated with spontaneous HCV clearance...

  9. A model of metabolism and clearance of organic compounds from the respiratory tract

    International Nuclear Information System (INIS)

    Gerde, P.; Dahl, A.R.

    1994-01-01

    In cases where inhalants induce toxicity in the airway epithelium, the mechanism of absorption is an important determinant of target dose. Absorption of organic solutes in the lungs occurs mainly by two consecutive mechanisms; molecular diffusion drives the chemicals into the tissues, and blood perfusion of the tissues removes the chemicals into the systemic circulation. Solutes having lipophilicities ranging from equally soluble in lipids and water to moderately more lipid-soluble are limited by the perfusion during clearance from the lungs. The perfusion-limited solute enters the blood circulation from all regions of the lungs within minutes and is distributed to other organs via the systemic circulation. In contrast, clearance of highly lipophilic toxicants, such as benzo(a)pyrene, from the lungs is diffusion-limited. The limiting process refers to the slowest transport mechanism of either perfusion or diffusion. Because of the short distance from the surface of the alveolar region to the capillary network, diffusion-limited clearance of highly lipophilic solutes occurs within minutes. In the thicker epithelium of the conducting airways, however, clearance may take hours. The purpose of the current modeling effort was to encompass both mechanisms of clearance in a single model in order to explore the influence of toxicant lipophilicity and local metabolism on the dosimetry at the airway portal-of-entry

  10. Hepatic and muscle clearance of physostigmine in the rat after i.v. administration

    International Nuclear Information System (INIS)

    Somani, S.M.; Unni, L.K.

    1986-01-01

    This study presents a method to calculate the extraction ratio (ER) from in vivo time course of liver metabolism using the physiological and pharmacokinetic parameters such as plasma flow rate, partition coefficient of drug between tissue and plasma and the elimination rate constant from tissues. Rats were administered 3 H-physostigmine (Phy), 100 μg/kg i.v.; and were sacrificed at various times. Tissues were removed and Phy and its metabolites were determined by HPLC. Half-life of Phy in liver and muscle was 24 and 20 min, respectively. ER of Phy in liver was .71 which showed a slight decrease at 10 min. Muscle ER was found to be .347 up to 5 min. Hepatic clearance was calculated to be 23.08 ml/min/kg (34.9% of systemic clearance) and the intrinsic clearance was 83.73 ml/min/kg which indicates that the changes in blood flow to the liver can cause a variation in the systematic clearance. Percentage dose of Phy retained in muscle was maximum and the clearance was 5.2 ml/min/kg suggesting that muscle might be acting as a storage depot for Phy prolonging the pharmacological effects. About 30-40% of radioactivity in the liver could not be washed off by 10% TCA or organic solvents indicating the irreversible binding of drug or metabolite to liver macromolecule

  11. Quantitative static scintigraphy for the evaluation of mucociliary clearance

    International Nuclear Information System (INIS)

    Maini, C.L.; Marchetti, L.; Giordano, A.; Antonelli Incalzi, R.; Fuso, L.

    1988-01-01

    Mucociliary clearance can be evaluated by radionuclide techniques, but such approaches have been usually implemented only in research-oriented laboratories because of technical difficulties. A very practical radionuclide method is here presented which requires only three static acquisitions after the inhalation of a polydisperse radioaerosol produced by a commercial generator. Data processing is also very simple. The diagnostic performance of the method was tested on a study population of 10 healthy subjects and 10 patients with athrophic bronchitis; a higly significance difference between normal and pathological patients was found. Its simple implementation and diagnostic yield recommend this radionuclide method for the routine assessment of mucociliary clearance also in busy clinical-oriented laboratories

  12. Sulfadoxine-pyrimethamine monotherapy in Tanzanian children gives rapid parasite clearance but slow fever clearance that is improved by chloroquine in combination therapy

    DEFF Research Database (Denmark)

    Tarimo, D S; Minjas, J N; Bygbjerg, I C

    2002-01-01

    Following widespread chloroquine (CQ) resistance, sulfadoxine plus pyrimethamine (SP) is now the first line antimalarial drug in a number of African countries including Tanzania. Unlike CQ, SP has no antipyretic effects, a feature that might delay fever clearance, and by acting on late stage para...... on possible delayed parasitological and clinical responses to SP that could result from its action on late stage parasites. Despite its diminishing antimalarial activity, CQ has beneficial in vivo antipyretic effects in therapeutic combination with SP.......Following widespread chloroquine (CQ) resistance, sulfadoxine plus pyrimethamine (SP) is now the first line antimalarial drug in a number of African countries including Tanzania. Unlike CQ, SP has no antipyretic effects, a feature that might delay fever clearance, and by acting on late stage...

  13. Importance of Bacterial Replication and Alveolar Macrophage-Independent Clearance Mechanisms during Early Lung Infection with Streptococcus pneumoniae

    Science.gov (United States)

    Camberlein, Emilie; Cohen, Jonathan M.; José, Ricardo; Hyams, Catherine J.; Callard, Robin; Chimalapati, Suneeta; Yuste, Jose; Edwards, Lindsey A.; Marshall, Helina; van Rooijen, Nico; Noursadeghi, Mahdad

    2015-01-01

    Although the importance of alveolar macrophages for host immunity during early Streptococcus pneumoniae lung infection is well established, the contribution and relative importance of other innate immunity mechanisms and of bacterial factors are less clear. We have used a murine model of S. pneumoniae early lung infection with wild-type, unencapsulated, and para-amino benzoic acid auxotroph mutant TIGR4 strains to assess the effects of inoculum size, bacterial replication, capsule, and alveolar macrophage-dependent and -independent clearance mechanisms on bacterial persistence within the lungs. Alveolar macrophage-dependent and -independent (calculated indirectly) clearance half-lives and bacterial replication doubling times were estimated using a mathematical model. In this model, after infection with a high-dose inoculum of encapsulated S. pneumoniae, alveolar macrophage-independent clearance mechanisms were dominant, with a clearance half-life of 24 min compared to 135 min for alveolar macrophage-dependent clearance. In addition, after a high-dose inoculum, successful lung infection required rapid bacterial replication, with an estimated S. pneumoniae doubling time of 16 min. The capsule had wide effects on early lung clearance mechanisms, with reduced half-lives of 14 min for alveolar macrophage-independent and 31 min for alveolar macrophage-dependent clearance of unencapsulated bacteria. In contrast, with a lower-dose inoculum, the bacterial doubling time increased to 56 min and the S. pneumoniae alveolar macrophage-dependent clearance half-life improved to 42 min and was largely unaffected by the capsule. These data demonstrate the large effects of bacterial factors (inoculum size, the capsule, and rapid replication) and alveolar macrophage-independent clearance mechanisms during early lung infection with S. pneumoniae. PMID:25583525

  14. Clearance rates of jellyfish and their potential predation impact on zooplankton and fish larvae in a neritic ecosystem (Limfjorden, Denmark)

    DEFF Research Database (Denmark)

    Hansson, L. J.; Moeslund, O.; Kiørboe, Thomas

    2005-01-01

    clearance potential were given assumed clearance rate values, but the collective predation potential by these species was evaluated to be small. Hydromedusae dominated numerically and had their highest potential clearance impact in spring, but overall jellyfish clearance potential on copepods was low during...

  15. RENAL CLEARANCE AND URINARY EXCRETION OF CIPROFLOXACIN IN GOATS

    Directory of Open Access Journals (Sweden)

    Z. IQBAL, I. JAVED, B. ASLAM, F. MUHAMMAD AND I. U. JAN

    2007-10-01

    Full Text Available The renal clearance and urinary excretion of ciprofloxacin were investigated in eight healthy female goats. In each animal, ciprofloxacin was administered intramuscularly at the rate of 5 mg/kg body weight. Following drug administration, blood and urine samples were collected at different time intervals and analyzed for ciprofloxacin and creatinine. High performance liquid chromatography (HPLC was used to determine the drug concentration in the plasma and urine. The value of diuresis after single administration of ciprofloxacin was 0.073 ± 0.014 ml/min/kg. Mean (± SE values for renal clearance of creatinine and ciprofloxacin were 1.870 ± 0.385 and 0.982 ± 0.166 ml/min/kg, respectively. The ratio between the renal clearance of ciprofloxacin and that of creatinine remained less than one, which was indicative of back diffusion. The mean (± SE value for the cumulative percent of ciprofloxacin dose excreted at 10 hours following its intramuscular administration was 13.03 ± 2.07. Based on these results, it was evident that besides glomerular filtration, renal handling of drug involved back diffusion also. It was concluded that in local goats glomerular filtration rate (GFR was lower than that reported for their foreign counterparts.

  16. DOE Integrated Safeguards and Security (DISS) historical document archival and retrieval analysis, requirements and recommendations

    Energy Technology Data Exchange (ETDEWEB)

    Guyer, H.B.; McChesney, C.A.

    1994-10-07

    The overall primary Objective of HDAR is to create a repository of historical personnel security documents and provide the functionality needed for archival and retrieval use by other software modules and application users of the DISS/ET system. The software product to be produced from this specification is the Historical Document Archival and Retrieval Subsystem The product will provide the functionality to capture, retrieve and manage documents currently contained in the personnel security folders in DOE Operations Offices vaults at various locations across the United States. The long-term plan for DISS/ET includes the requirement to allow for capture and storage of arbitrary, currently undefined, clearance-related documents that fall outside the scope of the ``cradle-to-grave`` electronic processing provided by DISS/ET. However, this requirement is not within the scope of the requirements specified in this document.

  17. LRP1 in Brain Vascular Smooth Muscle Cells Mediates Local Clearance of Alzheimer's Amyloid-β

    OpenAIRE

    Kanekiyo, Takahisa; Liu, Chia-Chen; Shinohara, Mitsuru; Li, Jie; Bu, Guojun

    2012-01-01

    Impaired clearance of amyloid-β (Aβ) is a major pathogenic event for Alzheimer’s disease (AD). Aβ depositions in brain parenchyma as senile plaques and along cerebrovasculature as cerebral amyloid angiopathy (CAA) are hallmarks of AD. A major pathway that mediates brain Aβ clearance is the cerebrovascular system where Aβ is eliminated through the blood-brain barrier (BBB) and/or degraded by cerebrovascular cells along the interstitial fluid drainage pathway. An Aβ clearance receptor, the low-...

  18. Bronchoscintigraphy and pulmonary clearance of 99mTc-albumin colloid in study of mucociliary clearance

    International Nuclear Information System (INIS)

    Mortensen, Jann

    1998-01-01

    A radioaerosol based method for measuring MC was introduced. It included an inhalation protocol that resulted in a predominant deposition of radioaerosol in the central bronchi and two simple procedures of evaluation: 1) a visual semi-quantitative bronchoscintigraphic analysis, and 2) a quantitative analysis of the retention of the radioactivity at different points after the inhalation. The results showed that bronchoscintigraphy was a simple technique that may be used to visualize a stimulation of mucociliary transport in the central airways of individuals that do not suffer from too much mucus hypersecretion. Comparison of the MC between individuals, however, should preferably be performed by the method of quantitative analysis of the radioactivity disappearance. A change of MC was found to be one of the first detectable effects on lung function of tobacco smoking. It could be effectively detected by measurement of radioaerosol clearance both by bronchoscintigraphy and simple quantification of the MC. The MC may be either acutely enhanced, reduced or not changed by smoking. Long-term smoking impairs MC. The enhancement of MC by β 2 -agonists was very limited in most patients with CF. In the hope of increasing mucus transport in patients with CF, these are treated with various chest physiotherapy techniques. The radioaerosol based method of measurement of MC could assess mucus clearance by chest physiotherapy and cough. (au)

  19. Tip Clearance Control Using Plasma Actuators

    Science.gov (United States)

    2007-03-01

    Clearance Control Using Plasma Actuators 4 posed by Denton (1993). A number of investigators have used partial shrouds, or " winglet " designs to...SDBD actuator Plasma enhanced aerodynamics has been demonstrated in a range of applications involving sepa- ration control, lift enhancement, drag... aerodynamic benefits of a squealer tip geometry. Specifically, the squealer tip is known to reduce the discharge coefficient of the tip gap, thereby

  20. U.S. nuclear fuel cycle regulatory issues on exclusion, exemption, and clearance

    International Nuclear Information System (INIS)

    Meck, R.A.

    1997-01-01

    The U.S. Nuclear Regulatory Commission is considering the use of exclusion and clearance in connection with the nuclear fuel cycle regulations. Clearance of licensed lands, buildings, structures, materials, and equipment could expose members of the public to radiation in addition to background. Establishing and implementing dose criteria for allowed concentrations of radioactivity in the various media raise challenging issues for the regulator. Clearance also raises significant regulatory issues, and these issues reflect trade-offs between concerns for protecting public health and safety, as well as other socioeconomic values and concerns. At the heart of the issues are the adequacy of risk analyses, acceptability of risks, underlying rationales, feasibility and cost of implementation, and exposures of the public to man-made radiation in relation to natural sources of radiation. (author)

  1. 76 FR 13020 - Agency Information Collection Activities: Comment Request; Generic Clearance for the Collection...

    Science.gov (United States)

    2011-03-09

    ... precision requirements or power calculations that justify the proposed sample size, the expected response... Clearance for the Collection of Qualitative Feedback on Agency Service Delivery AGENCY: Department of... Collection Request (Generic ICR): ``Generic Clearance for the Collection of Qualitative Feedback on Agency...

  2. Assessments of risk following the inhalation of plutonium oxide using observed lung clearance patterns

    International Nuclear Information System (INIS)

    Ramsden, D.

    1977-10-01

    Dose commitments and risk estimates for the inhalation of plutonium oxide are calculated using the lung clearance patterns observed at AEE Winfrith. These risks are compared with published data on risks arising from a lung clearance based on the ICRP Lung Model. (author)

  3. 51Cr-EDTA plasma clearance in severe renal failure determined by one plasma sample

    DEFF Research Database (Denmark)

    Kamper, A L; Nielsen, S L

    1989-01-01

    Two hundred and thirty-four measurements of standard 51Cr-EDTA plasma clearance were made in 50 patients with severe chronic renal failure. Based on these data two calculation methods were attempted using one plasma sample drawn 24 h after injection of 51Cr-EDTA. One of the methods used the 'one...... at zero-time was derived from injected dose and body surface area. This method might provide values 1.5 ml/min below or 0.8 ml/min above the established method of 51Cr-EDTA plasma clearance, which would be acceptable for clinical purposes. It is concluded that exact plasma clearance of 51Cr-EDTA in severe...... renal dysfunction (estimated clearance values below 21 ml/min) may be determined with adequate precision by one plasma sample drawn at 24 h after injection of the tracer without sampling at 5 h. This appears to be a very practical simplification....

  4. Ginsenoside compound K promotes β-amyloid peptide clearance in primary astrocytes via autophagy enhancement.

    Science.gov (United States)

    Guo, Jinhui; Chang, Li; Zhang, Xin; Pei, Sujuan; Yu, Meishuang; Gao, Jianlian

    2014-10-01

    The aim of the present study was to investigate the effect of ginsenoside compound K on β-amyloid (Aβ) peptide clearance in primary astrocytes. Aβ degradation in primary astrocytes was determined using an intracellular Aβ clearance assay. Aggregated LC3 in astrocyte cells, which is a marker for the level of autophagy, was detected using laser scanning confocal microscope. The effect of compound K on the mammalian target of rapamycin (mTOR)/autophagy pathway was determined using western blot analysis, and an enzyme-linked immunosorbent assay was used for Aβ detection. The results demonstrated that compound K promoted the clearance of Aβ and enhanced autophagy in primary astrocytes. In addition, it was found that phosphorylation of mTOR was inhibited by compound K, which may have contributed to the enhanced autophagy. In conclusion, compound K promotes Aβ clearance by enhancing autophagy via the mTOR signaling pathway in primary astrocytes.

  5. Oral sugar clearance and root caries prevalence in rheumatic patients with dry mouth symptoms.

    Science.gov (United States)

    Risheim, H; Arneberg, P; Birkhed, D

    1992-01-01

    The relationship between root caries, oral sugar clearance, salivary flow rate, and salivary counts of mutans streptococci, lactobacilli and candida has been studied in a group of 22 rheumatic patients (age range 40-72 years). The study group comprised all subjects volunteering for a clinical trial on relief of dry mouth symptoms. The median salivary flow was 0.09 ml/min at rest and 0.9 ml/min during chewing stimulation. The median sugar clearance time was about 5 min in the sublingual area and 16 min in the lower buccal vestibule. For subjects with 0-2 root caries lesions the clearance time at both sites was shorter than for subjects with 3 or more lesions (p flow, and high salivary counts of mutans streptococci. It is concluded that root caries in rheumatic patients with low salivary flow is significantly related to oral sugar clearance time.

  6. Optimization Based Clearance of Flight Control Laws A Civil Aircraft Application

    CERN Document Server

    Hansson, Anders; Puyou, Guilhem

    2012-01-01

    This book summarizes the main achievements of the EC funded 6th Framework Program project COFCLUO – Clearance of Flight Control Laws Using Optimization. This project successfully contributed to the achievement of a top-level objective to meet society’s needs for a more efficient, safer and environmentally friendly air transport by providing new techniques and tools for the clearance of flight control laws. This is an important part of the certification and qualification process of an aircraft – a costly and time-consuming process for the aeronautical industry.   The overall objective of the COFCLUO project was to develop and apply optimization techniques to the clearance of flight control laws in order to improve efficiency and reliability. In the book, the new techniques are explained and benchmarked against traditional techniques currently used by the industry. The new techniques build on mathematical criteria derived from the certification and qualification requirements together with suitable models...

  7. Blood lactate clearance after maximal exercise depends on active recovery intensity.

    Science.gov (United States)

    Devlin, J; Paton, B; Poole, L; Sun, W; Ferguson, C; Wilson, J; Kemi, O J

    2014-06-01

    High-intensity exercise is time-limited by onset of fatigue, marked by accumulation of blood lactate. This is accentuated at maximal, all-out exercise that rapidly accumulates high blood lactate. The optimal active recovery intensity for clearing lactate after such maximal, all-out exercise remains unknown. Thus, we studied the intensity-dependence of lactate clearance during active recovery after maximal exercise. We constructed a standardized maximal, all-out treadmill exercise protocol that predictably lead to voluntary exhaustion and blood lactate concentration>10 mM. Next, subjects ran series of all-out bouts that increased blood lactate concentration to 11.5±0.2 mM, followed by recovery exercises ranging 0% (passive)-100% of the lactate threshold. Repeated measurements showed faster lactate clearance during active versus passive recovery (P40%>passive recovery, Pexercise clears accumulated blood lactate faster than passive recovery in an intensity-dependent manner, with maximum clearance occurring at active recovery of 80% of lactate threshold.

  8. Evaluation of aorto-iliac disease with Doppler ultrasound and isotope clearance techniques

    International Nuclear Information System (INIS)

    Appleberg, M.; Lewis, J.D.

    1975-01-01

    The clearance of 99 mTc from the hamstring muscle compartment of patients with aorto-iliac or iliac disease was examined with the patients at rest and after exercise. The values were compared with those obtained in a group of controls and another group with superficial femoral, or femoropopliteal arterial occlusion. A statistically significant difference in the rate of 99 mTc clearance was found in patients with proximal vascular disease

  9. Dual roles for hepatic lectin receptors in the clearance of chilled platelets

    DEFF Research Database (Denmark)

    Rumjantseva, Viktoria; Grewal, Prabhjit K; Wandall, Hans H

    2009-01-01

    -GlcNAc moieties by galactosylation prevents clearance of short-term-cooled platelets, this strategy is ineffective after prolonged refrigeration. We report here that prolonged refrigeration increased the density and concentration of exposed galactose residues on platelets such that hepatocytes, through Ashwell-Morell...... transfusion. Inhibition of chilled platelet clearance by both beta(2) integrin and Ashwell-Morell receptors may afford a potentially simple method for storing platelets in the cold....

  10. 76 FR 13019 - Agency Information Collection Activities: Comment Request; Generic Clearance for the Collection...

    Science.gov (United States)

    2011-03-09

    ... requirements or power calculations that justify the proposed sample size, the expected response rate, methods... Clearance for the Collection of Qualitative Feedback on Agency Service Delivery AGENCY: Department of...): ``Generic Clearance for the Collection of Qualitative Feedback on Agency Service Delivery '' to OMB for...

  11. 76 FR 37825 - Agency Information Collection Activities; Generic Clearance for the Collection of Qualitative...

    Science.gov (United States)

    2011-06-28

    ... requirements or power calculations that justify the proposed sample size, the expected response rate, methods... Activities; Generic Clearance for the Collection of Qualitative Feedback on Agency Service Delivery AGENCY: U...): ``Generic Clearance for the Collection of Qualitative Feedback on Agency Service Delivery '' to OMB for...

  12. Effect of increases in lung volume on clearance of aerosolized solute from human lungs

    Energy Technology Data Exchange (ETDEWEB)

    Marks, J.D.; Luce, J.M.; Lazar, N.M.; Wu, J.N.; Lipavsky, A.; Murray, J.F.

    1985-10-01

    To study the effect of increases in lung volume on solute uptake, we measured clearance of /sup 99m/Tc-diethylenetriaminepentaacetic acid (Tc-DTPA) at different lung volumes in 19 healthy humans. Seven subjects inhaled aerosols (1 micron activity median aerodynamic diam) at ambient pressure; clearance and functional residual capacity (FRC) were measured at ambient pressure (control) and at increased lung volume produced by positive pressure (12 cmH2O continuous positive airway pressure (CPAP)) or negative pressure (voluntary breathing). Six different subjects inhaled aerosol at ambient pressure; clearance and FRC were measured at ambient pressure and CPAP of 6, 12, and 18 cmH2O pressure. Six additional subjects inhaled aerosol at ambient pressure or at CPAP of 12 cmH2O; clearance and FRC were determined at CPAP of 12 cmH2O. According to the results, Tc-DTPA clearance from human lungs is accelerated exponentially by increases in lung volume, this effect occurs whether lung volume is increased by positive or negative pressure breathing, and the effect is the same whether lung volume is increased during or after aerosol administration. The effect of lung volume must be recognized when interpreting the results of this method.

  13. Effect of increases in lung volume on clearance of aerosolized solute from human lungs

    International Nuclear Information System (INIS)

    Marks, J.D.; Luce, J.M.; Lazar, N.M.; Wu, J.N.; Lipavsky, A.; Murray, J.F.

    1985-01-01

    To study the effect of increases in lung volume on solute uptake, we measured clearance of /sup 99m/Tc-diethylenetriaminepentaacetic acid (Tc-DTPA) at different lung volumes in 19 healthy humans. Seven subjects inhaled aerosols (1 micron activity median aerodynamic diam) at ambient pressure; clearance and functional residual capacity (FRC) were measured at ambient pressure (control) and at increased lung volume produced by positive pressure [12 cmH 2 O continuous positive airway pressure (CPAP)] or negative pressure (voluntary breathing). Six different subjects inhaled aerosol at ambient pressure; clearance and FRC were measured at ambient pressure and CPAP of 6, 12, and 18 cmH 2 O pressure. Six additional subjects inhaled aerosol at ambient pressure or at CPAP of 12 cmH 2 O; clearance and FRC were determined at CPAP of 12 cmH 2 O. According to the results, Tc-DTPA clearance from human lungs is accelerated exponentially by increases in lung volume, this effect occurs whether lung volume is increased by positive or negative pressure breathing, and the effect is the same whether lung volume is increased during or after aerosol administration. The effect of lung volume must be recognized when interpreting the results of this method

  14. Studi Karakteristik Aliran Tiga Dimensi Dan Perpindahan Panas Pada Cascade Airfoil Dengan Pengaruh Clearance

    Directory of Open Access Journals (Sweden)

    Yusuf Wibisono

    2013-03-01

    Full Text Available Dalam dunia teknik khususunya mekanika fluida, aliran tiga dimensi merupakan hal yang sangat penting guna untuk mengetahui fenomena aliran dan perpindahan panas yang terjadi pada bluffbody cascade airfoil. Error atau loses yang terjadi pada cascade airfoil disebabkan oleh adanya aliran sekunder. Error atau loses tersebut menurut penilitian yang terlah dilakukan dapat dikurang dengan aspek clearance. Tujuan dari penilitian ini adalah untuk menganalisa karaktersistik aliran tiga dimensi serta perpindahan panas akibat adanya perubahan jarak antara leading edge antara cascade dan sudut serang serta bentuk geometri. hasil dari simulasi divisualisasikan dalam bentuk velocity dan pressure coefficient. Pada cascade airfoil dengan sudut serang 20° terjadi fenomena pada dinding clearance yaitu tip clearance flow di mana ketika aliran udara melewati dinding akan mengalami up stream yang mengakibatkan arah aliran menuju ke atas, sedangkan pada dinding airfoil ditemukan aliran sekunder berupa curl flow yang akhirnya membentuk spiral point pada trailing edge. Perubahan sudut serang menjadi -20° membuat perbedaan tekanan antara lower side dan upper side semakin lemah, begitu juga tip clearance flow yang terjadi pada wall clearance mengalami perubahan arah menjadi down stream yang mengakibatkan arah aliran menjuu kebawah. Perubahan sudut juga berpengaruh terhadap pressure coeficient pada boundary layer airfoil dan mengakibatkan blockage effect serta terjadinya vortex yang berbeda.

  15. Fault Diagnosis of Internal Combustion Engine Valve Clearance Using the Impact Commencement Detection Method

    Science.gov (United States)

    Jiang, Zhinong; Wang, Zijia; Zhang, Jinjie

    2017-01-01

    Internal combustion engines (ICEs) are widely used in many important fields. The valve train clearance of an ICE usually exceeds the normal value due to wear or faulty adjustment. This work aims at diagnosing the valve clearance fault based on the vibration signals measured on the engine cylinder heads. The non-stationarity of the ICE operating condition makes it difficult to obtain the nominal baseline, which is always an awkward problem for fault diagnosis. This paper overcomes the problem by inspecting the timing of valve closing impacts, of which the referenced baseline can be obtained by referencing design parameters rather than extraction during healthy conditions. To accurately detect the timing of valve closing impact from vibration signals, we carry out a new method to detect and extract the commencement of the impacts. The results of experiments conducted on a twelve-cylinder ICE test rig show that the approach is capable of extracting the commencement of valve closing impact accurately and using only one feature can give a superior monitoring of valve clearance. With the help of this technique, the valve clearance fault becomes detectable even without the comparison to the baseline, and the changing trend of the clearance could be trackable. PMID:29244722

  16. Fault Diagnosis of Internal Combustion Engine Valve Clearance Using the Impact Commencement Detection Method.

    Science.gov (United States)

    Jiang, Zhinong; Mao, Zhiwei; Wang, Zijia; Zhang, Jinjie

    2017-12-15

    Internal combustion engines (ICEs) are widely used in many important fields. The valve train clearance of an ICE usually exceeds the normal value due to wear or faulty adjustment. This work aims at diagnosing the valve clearance fault based on the vibration signals measured on the engine cylinder heads. The non-stationarity of the ICE operating condition makes it difficult to obtain the nominal baseline, which is always an awkward problem for fault diagnosis. This paper overcomes the problem by inspecting the timing of valve closing impacts, of which the referenced baseline can be obtained by referencing design parameters rather than extraction during healthy conditions. To accurately detect the timing of valve closing impact from vibration signals, we carry out a new method to detect and extract the commencement of the impacts. The results of experiments conducted on a twelve-cylinder ICE test rig show that the approach is capable of extracting the commencement of valve closing impact accurately and using only one feature can give a superior monitoring of valve clearance. With the help of this technique, the valve clearance fault becomes detectable even without the comparison to the baseline, and the changing trend of the clearance could be trackable.

  17. IFNL4 affects clearance of hepatitis C virus

    Science.gov (United States)

    Scientists have discovered a new human interferon gene, Interferon Lambda 4 (IFNL4), that affects clearance of the hepatitis C virus. They also identified an inherited genetic variant within IFNL4 that predicts how people respond to treatment for hepatit

  18. Effects of inflation and time value of money on an inventory system with deteriorating items and partially backlogged shortages

    Directory of Open Access Journals (Sweden)

    Chandra K. Jaggi

    2016-04-01

    Full Text Available As the long arm of the grinding, deep financial crisis continues to haunt the global economy, the effects of inflation and time value of money cannot be oblivious to an inventory system. Inflation, defined as a general rise in the prices of goods and services over a period of time, has monetary depreciation as one of its major side effects. And, since inventories correspond to substantial investment in capital for any organization, it would be unethical if the effects of inflation and time value of money are not considered while determining the optimal inventory policy. Moreover, deterioration of items is a phenomenon which cannot be ignored, as it may yield misleading results. Further, under the inflationary conditions, the different cost parameters including the price are bound to vary from cycle to cycle over the planning horizon. Another important factor is shortages which no retailer would prefer, and in practice are partially backlogged and partially lost. In order to convert the lost sales into sales, the retailer offers such customers an incentive, by charging them the price prevailing at the time of placing an order, instead of the current inflated price. Therefore, bearing in mind these facts, the present paper develops an inventory model for a retailer dealing with deteriorating items under inflationary conditions over a fixed planning horizon. The objective is to derive the optimal number of cycles and cycle length that maximizes the net present value of the total profit over a fixed planning horizon. An appropriate algorithm has been proposed to obtain the optimal solution. Finally, a numerical example is provided to illustrate the proposed model. Sensitivity analysis of the optimal solution with respect to major parameters is carried out and some managerial inferences have been presented.

  19. Numerical Analysis of the Influence of Clearance on Stress State and Contact Pressure in Plain Bearings

    Directory of Open Access Journals (Sweden)

    Vasile Cojocaru

    2017-12-01

    Full Text Available In the analysis of plain bearings by finite element method it is important to model as closely to real state the aspects that influence the stress and contact pressure: the loading mode, the properties of the materials, the lubrication system, the clearance between the shaft and the bearing body, the evolution in time of clearance correlated with the wear, etc. In order to study the effect of the clearance on the stress state, a plain bearing with nominal diameter d=40 mm was modeled. The contact pressure and the equivalent stress were computed for six discrete values of clearance, range from c=0 to c=0.3 mm. It has been shown that the increase of clearance generates an increase of the equivalent stress and contact pressure. The growth rate is higher for contact pressure, due to the decrease of the contact surface between the shaft and the bearing body

  20. pH modulation and salivary sugar clearance of different chocolates in children: A randomized clinical trial

    Directory of Open Access Journals (Sweden)

    SVSG Nirmala

    2016-01-01

    Full Text Available Background: Sugars that occur naturally in foods and those added in processed foods may act as the source for fermentable carbohydrates and may initiate caries process. Among all the foods consumed by children, chocolates form an important constituent. A wide variety of chocolates are available in the Indian market and very few studies have compared their acidogenicity and salivary sugar clearance. Objectives: To compare the acidogenicity and salivary sugar clearance of 6 different commercially available chocolates in the Indian market. Materials and Methods: Thirty subjects aged 10-15 years were selected randomly from one of the available public schools in Nellore city. Six commercially available chocolates in the Indian market were divided into three groups, unfilled (dark and milk chocolate, filled (wafer and fruit and nuts chocolate, and candy (hard milk and mango-flavored candy groups. Plaque pH values and salivary sugar clearance rates are assessed at baseline, 5, 10, 15, 20, and 30 min after consumption. All the data obtained were statistically evaluated using independent sample t-test and one-way ANOVA for multiple group comparisons. Results: Mango-flavored candy had maximum fall in plaque pH and least fall in plaque pH was recorded with milk chocolate. Fruit and nuts chocolate had a maximum clearance of salivary sugar and least fall in the salivary sugar clearance was recorded with dark chocolate. When the plaque pH and salivary sugar clearance of all the chocolates were assessed, it was seen that the values were statistically significant at all the time intervals (P < 0.05. Conclusion: Dark chocolate had a high fall in pH and milk chocolate had low salivary sugar clearance which signifies that unfilled chocolates are more cariogenic than other chocolates. Even though mango-flavored candy had maximum fall in plaque pH, its salivary sugar clearance was high.

  1. pH modulation and salivary sugar clearance of different chocolates in children: A randomized clinical trial.

    Science.gov (United States)

    Nirmala, Svsg; Quadar, Mohammed Akhil; Veluru, Sindhuri

    2016-01-01

    Sugars that occur naturally in foods and those added in processed foods may act as the source for fermentable carbohydrates and may initiate caries process. Among all the foods consumed by children, chocolates form an important constituent. A wide variety of chocolates are available in the Indian market and very few studies have compared their acidogenicity and salivary sugar clearance. To compare the acidogenicity and salivary sugar clearance of 6 different commercially available chocolates in the Indian market. Thirty subjects aged 10-15 years were selected randomly from one of the available public schools in Nellore city. Six commercially available chocolates in the Indian market were divided into three groups, unfilled (dark and milk chocolate), filled (wafer and fruit and nuts chocolate), and candy (hard milk and mango-flavored candy) groups. Plaque pH values and salivary sugar clearance rates are assessed at baseline, 5, 10, 15, 20, and 30 min after consumption. All the data obtained were statistically evaluated using independent sample t-test and one-way ANOVA for multiple group comparisons. Mango-flavored candy had maximum fall in plaque pH and least fall in plaque pH was recorded with milk chocolate. Fruit and nuts chocolate had a maximum clearance of salivary sugar and least fall in the salivary sugar clearance was recorded with dark chocolate. When the plaque pH and salivary sugar clearance of all the chocolates were assessed, it was seen that the values were statistically significant at all the time intervals (P pH and milk chocolate had low salivary sugar clearance which signifies that unfilled chocolates are more cariogenic than other chocolates. Even though mango-flavored candy had maximum fall in plaque pH, its salivary sugar clearance was high.

  2. Tear clearance and ocular symptoms in patients treated with preservative-free prostaglandins.

    Science.gov (United States)

    Giménez-Gómez, R; García-Catalán, M R; Gallardo-Galera, J M

    2013-03-01

    To assess the effects on dry eye symptoms and tear dynamics of switching from a prostaglandin with a preservative to a preservative-free prostaglandin. Fourteen patients (N=28 eyes) with open-angle glaucoma and dry eye symptons, treated with preserved latanoprost, travoprost or bimatoprost were included in this uncontrolled prospective study. Ocular symptoms were analysed using a validated ocular surface disease questionnaire and ocular signs were assessed with tear clearance, Schirmer and tear function index test (TFI=Schirmer/clearance). Patients were assigned to preservative-free tafluprost treatment, and measurements were repeated 4 weeks after change of medication. Wilcoxon test and Spearman correlation coefficient were used in the statistical analysis. No statistically significant difference in intraocular pressure (IOP) was observed after switching to tafluprost. Mean IOP at baseline was 20.4 mmHg (SD2.2) and after 4 weeks 19.9 mmHg (SD2.6), (P>.05). The mean questionnaire score significantly decreased from 9.7 (SD3.7) at baseline to 5.4 (SD2.7) after one month (P.05). At baseline, tear clearance=0.13 (SD0.07), Schirmer=10.7 mm (SD6) and TFI=80 (48-156). After 4 weeks, tear clearance=0.1(SD0.07), Schirmer=9.5 mm (3.9) and TFI=104 (48-216). A significant association between questionnaire score and tear clearance after 4 weeks was observed (Spearman coefficient=0.62; P=.014). Switching from preservative prostaglandin with a preservative to preservative-free tafluprost treatment improves dry eye symptoms and suggests an improvement in TFI. Copyright © 2012 Sociedad Española de Oftalmología. Published by Elsevier Espana. All rights reserved.

  3. Using cholecystokinin to facilitate endoscopic clearance of large common bile duct stones

    Science.gov (United States)

    Tao, Tao; Zhang, Qi-Jie; Zhang, Ming; Zhu, Xiao; Sun, Shu-Xia; Li, Yan-Qing

    2014-01-01

    AIM: To evaluate the effect of cholecystokinin (CCK) during extracorporeal shockwave lithotripsy (ESWL) in the clearance of common bile duct (CBD) stones in endoscopic retrograde cholangiopancreatography (ERCP). METHODS: Between January 2007 and September 2012, patients with large CBD stones who were treated with ESWL and ERCP were identified retrospectively. Patients were randomized in equal numbers to cholecystokinin (CCK) and no CCK groups. For each CCK case, a dose (3 ng/kg per min for 10 min) of sulfated octapeptide of CCK-8 was administered intravenously near the beginning of ESWL. ERCP was performed 4 h after a session of ESWL. The clearance rate of the CBD was assessed between the two groups. RESULTS: A total of 148 consecutive cases (CCK group: 74, no CCK group: 74) were tallied. Overall there were 234 ESWLs and 228 ERCPs in the 148 cases. The use of CCK showed a significantly higher rate of successful stone removal in the first ESWL/ERCP procedure (71.6% vs 55.4%, P = 0.035), but resulted in similar outcomes in the second (42.8% vs 39.4%) and third (41.7% vs 40.0%) sessions, as well as total stone clearance (90.5% vs 83.8%). The use of mechanical lithotripsy was reduced in the CCK group (6.8% vs 17.6%, P = 0.023), and extremely large stone (≥ 30 mm) removal was higher in the CCK group (72.7% vs 41.7%, P = 0.038). CONCLUSION: CCK during ESWL can aid with the clearance of CBD stones in the first ESWL/ERCP session. Mechanical lithotripsy usage was reduced and the extremely large stone (≥ 30 mm) clearance rate can be raised. PMID:25110439

  4. Hepatectomy Based on Future Liver Remnant Plasma Clearance Rate of Indocyanine Green

    Directory of Open Access Journals (Sweden)

    Yuichiro Uchida

    2016-01-01

    Full Text Available Background. Hepatectomy, an important treatment modality for liver malignancies, has high perioperative morbidity and mortality rates. Safe, comprehensive criteria for selecting patients for hepatectomy are needed. Since June 2011, we have used a cut-off value of ≧ 0.05 for future liver remnant plasma clearance rate of indocyanine green as a criterion for hepatectomy. The aim of this study was to verify the validity of this criterion. Methods. From June 2011 to December 2015, 212 hepatectomies were performed in Tenri Yorozu Hospital. Of these 212 patients, 107 who underwent preoperative computed tomography imaging volumetry, indocyanine green clearance test, and hepatectomy (excluding partial resection or enucleation were retrospectively analyzed. Results. There was no postoperative mortality. Posthepatectomy liver failure occurred in 59 patients (55.1% (International Study Group of Liver Surgery Grade A: 43 cases (40.2%, Grade B: 16 cases (15.0%, and Grade C: no cases. Operative morbidity greater than Clavien-Dindo Grade 3 occurred in 23 patients (21.5%. A low future liver remnant plasma clearance rate of indocyanine green was a good predictor for Grade B cases (area under curve = 0.804; 95% confidence interval, 0.712–0.895. Conclusion. Liver remnant plasma clearance rate of indocyanine green is a valid criterion for hepatectomy.

  5. Evaluation of plasma clearance by synthesis of continuous infusion: principles and use

    International Nuclear Information System (INIS)

    Chonacky, N.J.; Thomas, F.D.

    1986-01-01

    There is a technique of engineering analysis which can be described as impulse synthesis which uses the observational data of a system's response to a single sharp blow in order to predict its response to a steady force. This same technique has been applied to the calculation of in situ drug levels and for calculating plasma clearance values. The purpose of this paper is to elucidate the principles of this calculation technique and to critically assess its application to plasma clearance studies. We begin by tracing the history of the measurement of renal clearance of plasma. We then proceed to exposit the relevant principles of the synthesis technique. Finally, we report the results of our application of this technique to the analysis of simulated data in a manner intended to be of use to clinicians who might wish to consider employing the technique

  6. Effect of α-naphthylisothiocyanate on blood clearance of 99mTc-phytate in dogs

    International Nuclear Information System (INIS)

    Shibata, Hiroshi; Kohno, Masahiro; Katoh, Hirotake

    1989-01-01

    The effect of α-naphthylisothiocyanate (ANIT) on blood clearance of 99m Tc-phytate ( 99m Tc-P) in dogs was examined, and blood clearance test of 99m Tc-P was compared with the cases of serum transaminase test or serum bilirubin test. Serum transaminase and bilirubin levels in dogs increased after ANIT administration, however, the degree of increase in these parameters was much lower than the cases in rats. The disappearance rate of 99m Tc-P from blood in dogs decreased with the increase in dose of ANIT and with the passage of time after the ANIT administration. Changes of the blood clearance of 99m Tc-P after ANIT treatment in dogs may be influenced by the disorder in the hepatocytes rather than in the bile ductule cells. The blood clearance test of 99m Tc-P in dogs showed a sensitive reaction for the acute hepatic dysfunction induced by ANIT equally to the serum transaminase test or the serum bilirubin test. (author)

  7. Hepatic clearance of 6 polyaromatic aromatic hydrocarbons by isolated trout livers: Prediction from in vitro clearance by liver S9 fractions

    Science.gov (United States)

    An isolated perfused trout liver preparation was used to evaluate in vitro-to-in vivo metabolism extrapolation procedures for fish. Hepatic clearance (CLH) studies were conducted with six polyaromatic hydrocarbons (PAH) using an experimental design wherein each liver acted as it...

  8. Protein clearance from the air spaces and lungs of unanesthetized sheep over 144 h

    International Nuclear Information System (INIS)

    Berthiaume, Y.; Albertine, K.H.; Grady, M.; Fick, G.; Matthay, M.A.

    1989-01-01

    We studied the rate, the routes, and the mechanisms for protein clearance from the air spaces and lungs of 20 unanesthetized sheep over 144 h. We instilled 100 ml of autologous serum labeled with 125I-albumin into one lung. At the end of 24, 48, 96, or 144 h, the lungs were removed and the residual native protein and 125I-albumin in the air spaces were determined by bronchoalveolar lavage. Also the fraction of the instilled 125I-albumin remaining in the rest of the lung was measured in the lung homogenate. Clearance of the 125I-albumin from the lung into the plasma, lymph, thyroid, urine, and feces was also determined. The removal of both the 125I-albumin and the native protein from the air spaces was slow, following a monoexponential decline. The removal rate of the 125I-albumin from the air spaces was slightly but significantly faster (1.6%/h) than the clearance rate of the native protein (0.9%/h). Clearance of the 125I-albumin from the lung also followed a slow monoexponential decline at a rate of 1.4%/h. At all time periods, 75% of the 125I-albumin remaining in the lung was located in the air spaces, thus indicating that the pulmonary epithelium is the principal barrier to protein clearance from the normal lung. Macrophages appeared to play a minor role in alveolar protein clearance because the quantity of 125I-albumin present in the phagocytic cells in the air spaces was less than 1% of the instilled 125I-albumin at all time periods. However, macrophages may play some role in protein clearance after 48 h because we visualized phagolysosomes in macrophages, and there was an increase in free iodine in lung lavage, urine, thyroid, and feces after 48 h. However, gel electrophoretic studies showed that most of the 125I-albumin was cleared from the lung as an intact molecule, although only 24.7 +/- 4.7% of the 125I-albumin was cleared by the lymphatics

  9. Mucociliary clearance following tracheal resection and end-to-end anastomosis.

    Science.gov (United States)

    Toomes, H; Linder, A

    1989-10-01

    Mucociliary clearance is an important cleaning system of the bronchial tree. The complex transport system reacts sensitively to medicinal stimuli and inhaled substances. A disturbance causes secretion retention which encourages the development of acute and chronic pulmonary diseases. It is not yet known in which way sectional resection of the central airway effects mucociliary clearance. A large number of the surgical failures are attributable to septic complications in the area of the anastomosis. In order to study the transportation process over the anastomosis, ten dogs underwent a tracheal resection with end-to-end anastomosis, and the mucociliary activity was recorded using a bronchoscopic video-technical method. Recommencement of mucous transport was observed on the third, and transport over the anastomosis from the sixth to tenth, postoperative days. The mucociliary clearance had completely recovered on the twenty-first day in the majority of dogs. Histological examination of the anastomoses nine months postoperatively showed a flat substitute epithelium without cilia-bearing cells in all dogs. This contrasts with the quick restitution of the transport function. In case of undamaged respiratory mucosa, a good adaptation of the resection margins suffices for the mucous film to slide over the anastomosis.

  10. Evaluation of aorto-iliac disease with Doppler ultrasound and isotope clearance techniques

    Energy Technology Data Exchange (ETDEWEB)

    Appleberg, M [University of the Witwatersrand, Johannesburg (South Africa). Dept. of Surgery; Lewis, J D

    1975-10-04

    The clearance of /sup 99/mTc from the hamstring muscle compartment of patients with aorto-iliac or iliac disease was examined with the patients at rest and after exercise. The values were compared with those obtained in a group of controls and another group with superficial femoral, or femoropopliteal arterial occlusion. A statistically significant difference in the rate of /sup 99/mTc clearance was found in patients with proximal vascular disease.

  11. Creatinine Clearance and Estimated Glomerular Filtration Rate – When are they Interchangeable

    OpenAIRE

    Šimetić, Lucija; Zibar, Lada; Drmić, Sandra; Begić, Ivana; Šerić, Vatroslav

    2015-01-01

    Study goal was to examine which of glomerular rate equations is most suitable for prediction of creatinine clearance. Using a retrospective review of data from 500 hospital patients we calculated glomerular filtration rate according to Cockcroft-Gault equation (C-G), Modification of Diet in Renal Disease Study equation (MDRD) and Chronic Kidney Disease Epidemiology Collaboration equation (CKD-EPI). We determined if results of these equations were compatible with creatinine clearance, and does...

  12. Diesel Engine Valve Clearance Detection Using Acoustic Emission

    Directory of Open Access Journals (Sweden)

    Fathi Elamin

    2010-01-01

    Full Text Available This paper investigated, using experimental method, the suitability of acoustic emission (AE technique for the condition monitoring of diesel engine valve faults. The clearance fault was adjusted experimentally in an exhaust valve and successfully detected and diagnosed in a Ford FSD 425 four-cylinder, four-stroke, in-line OHV, direct injection diesel engine. The effect of faulty exhaust valve clearance on engine performance was monitored and the difference between the healthy and faulty engine was observed from the recorded AE signals. The measured results from this technique show that using only time domain and frequency domain analysis of acoustic emission signals can give a superior measure of engine condition. This concludes that acoustic emission is a powerful and reliable method of detection and diagnosis of the faults in diesel engines and this is considered to be a unique approach to condition monitoring of valve performance.

  13. Semen amyloids participate in spermatozoa selection and clearance.

    Science.gov (United States)

    Roan, Nadia R; Sandi-Monroy, Nathallie; Kohgadai, Nargis; Usmani, Shariq M; Hamil, Katherine G; Neidleman, Jason; Montano, Mauricio; Ständker, Ludger; Röcker, Annika; Cavrois, Marielle; Rosen, Jared; Marson, Kara; Smith, James F; Pilcher, Christopher D; Gagsteiger, Friedrich; Sakk, Olena; O'Rand, Michael; Lishko, Polina V; Kirchhoff, Frank; Münch, Jan; Greene, Warner C

    2017-06-27

    Unlike other human biological fluids, semen contains multiple types of amyloid fibrils in the absence of disease. These fibrils enhance HIV infection by promoting viral fusion to cellular targets, but their natural function remained unknown. The similarities shared between HIV fusion to host cell and sperm fusion to oocyte led us to examine whether these fibrils promote fertilization. Surprisingly, the fibrils inhibited fertilization by immobilizing sperm. Interestingly, however, this immobilization facilitated uptake and clearance of sperm by macrophages, which are known to infiltrate the female reproductive tract (FRT) following semen exposure. In the presence of semen fibrils, damaged and apoptotic sperm were more rapidly phagocytosed than healthy ones, suggesting that deposition of semen fibrils in the lower FRT facilitates clearance of poor-quality sperm. Our findings suggest that amyloid fibrils in semen may play a role in reproduction by participating in sperm selection and facilitating the rapid removal of sperm antigens.

  14. Further training in the fields of radiological characterisation and clearance

    International Nuclear Information System (INIS)

    Bothe, M.; Feinhals, J.; Neukaeter, E.

    2016-01-01

    Radiological characterisation and clearance require specific knowledge and skills. Targeted further training of the staff is one possibility to get this knowledge and skills. A modular concept was established, which allows adaption to specific requests of the institution and state of knowledge and skills of participants. The modules have following focuses: ''radiological characterisation and clearance'', ''sampling'' and ''measurement and sampling plans'' and consist half-and-half of lectures and group works. In group works participants apply new knowledge to examples of the installation or simulated scenarios and afterwards they present and discuss the results. This concept was carried out for different institutions and is planned for some more.

  15. Bone blood flow measured by 41Ar clearance formed by 44Ca(n,α)41Ar

    International Nuclear Information System (INIS)

    Rosenthal, M.S.; DeLuca, P.M. Jr.; Pearson, D.W.; Nickles, R.J.

    1983-01-01

    A technique to measure regional inert gas washout in bone, in vivo, by measuring 41 Ar clearance formed by fast-neutron activation of 44 Ca has been developed. Following fast-neutron irradiation of whole rats, the perfusion-limited clearance of 41 Ar was measured for both dead and living rats. The clearance rate for the live rats indicate that the bone perfusion is in the range of 3 to 20 ml/100 Argon distribution volume

  16. Effects of shoe sole geometry on toe clearance and walking stability in older adults.

    Science.gov (United States)

    Thies, S B; Price, C; Kenney, L P J; Baker, R

    2015-07-01

    Thirty-five percent of people above age 65 fall each year, and half of their falls are associated with tripping: tripping, an apparently 'mundane' everyday problem, therefore, significantly impacts on older people's health and associated medical costs. To avoid tripping and subsequent falling, sufficient toe clearance during the swing phase is crucial. We previously found that a rocker-shaped shoe sole enhances toe clearance in young adults, thereby decreasing their trip-risk. This study investigates whether such sole design also enhances older adults' toe clearance, without inadvertently affecting their walking stability. Toe clearance and its variability are reported together with measures of walking stability for twelve older adults, walking in shoes with rocker angles of 10°, 15°, and 20°. Surface inclinations (flat, incline, decline) were chosen to reflect a potential real-world environment. Toe clearance increased substantially from the 10° to the 15° rocker angle (p=0.003) without compromising measures of walking stability (p>0.05). A further increase in rocker angle to 20° resulted in less substantial enhancement of toe clearance and came at the cost of a decrease in gait speed on the decline. The novelty of this investigation lies in the exploration of the trade-off between reduction of trip-risk through footwear design and adverse effects on walking stability on real-life relevant surfaces. Our two studies suggest that the current focus on slip-resistance in footwear design may need to be generalised to include other factors that affect trip-risk. Copyright © 2015 The Authors. Published by Elsevier B.V. All rights reserved.

  17. Turbo machine tip clearance and vibration measurements using a fibre optic laser Doppler position sensor

    Science.gov (United States)

    Pfister, T.; Büttner, L.; Czarske, J.; Krain, H.; Schodl, R.

    2006-07-01

    This paper presents a novel fibre optic laser Doppler position sensor for single blade tip clearance and vibration measurements at turbo machines, which offers high temporal resolution and high position resolution simultaneously. The sensor principle is based on the generation of a measurement volume consisting of two superposed fan-like interference fringe systems with contrary fringe spacing gradients using wavelength division multiplexing. A flexible and robust measurement system with an all-passive fibre coupled measurement head has been realized employing diffractive and refractive optics. Measurements of tip clearance and rotor vibrations at a transonic centrifugal compressor performed during operation at up to 50 000 rpm (833 Hz) corresponding to 21.7 kHz blade frequency and 586 m s-1 blade tip velocity are presented. The results are in excellent agreement with those of capacitive probes. The mean uncertainty of the position measurement was around 20 µm and, thus, considerably better than for conventional tip clearance probes. Consequently, this sensor is capable of fulfilling the requirements for future active clearance control systems and has great potential for in situ and online tip clearance and vibration measurements at metallic and non-metallic turbine blades with high precision.

  18. Determination of Minimum Air Clearances for a 420kV Novel Unibody Composite Cross-Arm

    DEFF Research Database (Denmark)

    Jahangiri, Tohid; Bak, Claus Leth; Silva, Filipe Miguel Faria da

    2015-01-01

    One of the most important requirements of any overhead line tower is determining the air clearances between live parts and earthed parts such as phase conductor and tower structure. In contrast to traditional steel lattice towers, the recently introduced fully composite pylon is completely made....... This paper presents the insulation coordination studies to determine minimum required air clearances on the unibody cross-arm. The procedure and relevant equations to calculate minimum air clearances to avoid flashover between phases’ conductors as well as top phase conductor and shield wire are based...

  19. The UK Nuclear Industry Code of Practice on Clearances and Exemptions

    International Nuclear Information System (INIS)

    Owen, D.

    2004-01-01

    In 2001, the major nuclear organisations in the United Kingdom started development of a document that would identify and facilitate consistent the application of good practice within the industry for clearing and sentencing of articles, substances and wastes which may be clean, or radioactive at very low levels below thresholds of regulatory control. The document includes: (i) Clarification of the industry's interpretation of legislation associated with the clearance and sentencing of articles, substances and wastes which are or have the potential to have been contaminated by radioactivity or activated by nuclear radiations; (ii) Industry agreement on what is considered to be the good practice where legislation is imprecise or unclear, (iii) A standard management framework, adopted by all organisations within the nuclear industry, that should justify safe and efficient clearance of potentially radioactive articles, substances and wastes; and (IV) Agreed guidance on the principles, processes and practices which should be followed for clearances and sentencing The Document mandates a system that allows articles and substances to be released from further control, where this is appropriate, using robust radiological protection principles. The need to avoid sentencing of clean materials as radioactive waste where this is not appropriate, the primacy of bulk, rather than surface radioactivity clearance criteria, and the need to disallow such clearances until all relevant legislation has been satisfied, are all clear principles contained within the document. An interim issue of the Code of Practice was issued in May 2003. This version has been formally adopted by all of the major users of radioactive material in the United Kingdom, and has two main objectives: -Trial use of the concepts at the working level, and - As a basis for further discussion with interested stakeholders. The paper summarises: - How the interim version of the Code of Practice was developed; - The

  20. SIMULASI SISTEM DINAMIK UNTUK MENINGKATKAN KINERJA RANTAI PASOK (Studi Kasus di Industri Kulit PT Lembah Tidar Jaya Magelang

    Directory of Open Access Journals (Sweden)

    Eko Muh Widodo

    2012-02-01

    Full Text Available Dalam sebuah industri, informasi mengambil peran penting dalam setiap aspek yang melibatkan manajemen industri. Informasi yang tidak akurat akan asupan produksi perlambatan dan pengaturan couse tidak sempurna. Supply chain adalah rantai baik secara kuantitatif dan kualitatif yang dapat diterima formulir hulu hingga hilir dan itu adalah bentuk terbesar informasi. Penelitian dilakukan pada indikator kinerja supply chain, adalah produk tingkat persediaan dan order backlog. Dalam analisa indikator, ada beberapa langkah asupan di PT industri kulit. Lembah Tidar Jaya Magelang yang Beam House asupan, Retainning asupan dan Finishing asupan. Indikator pengukuran untuk langkah tiga menggunakan aplikasi simulasi sistem dinamik dengan menggunakan Berbasis Model Berbagi Informasi dan Berbagi Informasi Model demmand. Output implikasi ini dilakukan untuk mengetahui perilaku persediaan dan pesanan backlog houbig PT. Lembah Tidar Jaya Magelang. Penerapan simulasi di tingkat persediaan produk dan backlog indikator agar memberi hasil perilaku persediaan kenaikan atau penurunan antara Berdasarkan Model dan demmand Berbagi Model. Order backlog penurunan juga invluenced dengan persediaan, untuk Permintaan Berbagi cenderung stabil, dan dapat menurunkan tingkat backlog order yang menunjukkan besar dalam asupan industri kulit di PT. Lembah Tidar Jaya Magelang. Kata kunci: Supply Chain, Dinamic Sistem, Produk Level Inventory, Order Backlog In an industrial, information takes important role in every aspect involving industrial management. Inaccurate information will slowdown production procces and couse imperfect arrangement. Supply chain is a good chain quantitatively and qualitatively which can be accepted form upstream to downstream and it is the biggest form of information. The research done on performance indicator of supply chain, it is product inventory level and order backlog. In analizing the indicator, there are some procces step in leather industri PT. Lembah

  1. Proficiency testing criteria for clearance level in solid waste gamma measurement in Taiwan

    International Nuclear Information System (INIS)

    Chen, Chun-Liang; Wang, Jeng-Jong; Chiu, Huang-Sheng

    2013-01-01

    To guarantee the measurement quality for clearance level in solid waste material, the Institute of Nuclear Energy Research (INER) established the criteria for proficiency testing of clearance level measurement. INER and the Taiwan Accreditation Foundation (TAF) organized the Technique Committee Meeting twice to discuss these criteria in 2011. The participating laboratories must completely conform to the ISO/IEC 17025, and they also must meet the requirements of the criteria. According to the criteria, the participating laboratories analyzed the minimum detectable amount (MDA) and that should be less than 20% of the clearance level (AMDA) given in the Atomic Energy Council's (AEC) “Regulations on Clearance Level for Radioactive Waste Management”. The testing results should conform to the deviation and traceability requirements. - Highlights: • The participating laboratories must completely conform to the ISO/IEC 17025 • The proficiency testing items were basically in two categories, box and barrel types • Analyzed the MDA and that should be less than 20% of the release level given in the AEC. • The are three limitations: MDA< AMDA, -0.25< Bi<+0.5, and En≤1.0 and uncertainty<20%

  2. Joint Logistics Commanders Guide for the Management of Multinational Program,

    Science.gov (United States)

    1981-07-01

    purchase of the A-300 Airbus and the 1977 record-breaking export performance of the French and UK aerospace industries of around $5 billion and $2 billion...DIS. They are the Defense Industrial Security Clearance Office ( DISCO ), the Defense Industrial Security Institute (DISI), and the Office of Industrial...Security International (ISI). Defense Industrial Security Clearance Office ( DISCO ) The Defense Industrial Security Program (DISP) establishes pro

  3. Clearance of materials resulting from the use of radionuclides in medicine, industry and research

    International Nuclear Information System (INIS)

    1998-02-01

    It has long been recognized that the use of sources of radiation should be regulated. The recommended regulatory approach is based on a system of notification and authorization exemplified by the IAEA International Basic Safety Standards for Protection Against Ionizing Radiation and for the Safety of Radiation Sources (BSS). However, some types of radiation source do not meet to be subject to regulatory control because they can only give rise to trivial radiation hazards. Such sources may be exempted or cleared from the requirements of regulatory control. Exemption applies to radiation sources which do not enter the regulatory control regime, while clearance is relevant to radiation sources which were within the regulatory regime but can be released because they present an insignificant risk to health. It is the latter situation which is the subject of this publication. While the emphasis of the report is on providing guidance on the clearance process and on methods for determining clearance leaves, taking account of site specific factors as appropriate, a set of conservatively derived generic clearance levels is also presented. These are expected to be of considerable help to users of small quantities of radionuclides in laboratories and hospitals and their regulators. They can be used, taking due account of the associated notes of caution, as reference levels for determining when clearance is the appropriate option for disposing of the materials

  4. Delayed plasma clearance and hepatic uptake of lymph chylomicron 14C-cholesterol in marginally zinc-deficient rats

    International Nuclear Information System (INIS)

    Koo, S.I.; Algilani, K.; Norvell, J.E.; Henderson, D.A.

    1986-01-01

    Previously, chylomicrons from marginally zinc-deficient rats were shown to be abnormally large, with markedly reduced levels of apoproteins C and E. In the present study, effects of such changes on the plasma clearance and hepatic uptake of chylomicron cholesterol were investigated in rats fed 3 ppm of zinc (ZD), as compared with those fed 30 ppm of zinc (CT). The rate of plasma clearance was determined by plasma 14C-radioactivity at different intervals after intravenous injection of lymph chylomicrons labeled in vivo with 14C-cholesterol. The 14C-clearance curves were nonlinear, consisting of an initial rapid phase followed by a slow phase of clearance. The initial 14C-clearance was significantly (p less than 0.05) delayed whether the labeled chylomicrons from ZD donors were injected into ZD or CT recipients. The hepatic 14C-recovery in extracted lipids was also significantly lower in ZD rats. The present data provide first evidence that a marginal level of zinc deficiency produces a significant delay in the plasma clearance and hepatic uptake of chylomicron cholesterol. This may be attributable in part to the molecular alterations of chylomicrons induced by zinc deficiency

  5. Effect of tip clearance on wall shear stress of an axial LVAD

    Science.gov (United States)

    Sarath, S.; Vikas, R.

    2017-09-01

    Wall shear stress is a crucial parameter used for blood damage analysis, and typically a value of 400 Pa is set as a limit. Tip clearance is a major factor contributing to hemolysis and pump efficiency. In this study, different tip gap configurations are used to analyse the wall shear stress developed on the blade surface of a constant thickness blade design, and a varying thickness blade design using CFD analysis. It was found that, for a particular geometry, as the clearance gap reduces, flow rate over the high wall shear stress area decreases even though the high wall shear stress span is found to extend. For each design, the optimum clearance gap is iteratively attained, keeping the maximum WSS as a limiting factor. Thus a better pump designs is obtained, whose leakage flow patterns are lower than that of the initial design, hence also leading to higher pump efficiency.

  6. The metabolic clearance rate of corticosterone in lean and obese male Zucker rats

    International Nuclear Information System (INIS)

    White, B.D.; Corll, C.B.; Porter, J.R.

    1989-01-01

    The obese Zucker rat is an animal model of human juvenile-onset obesity. These rats exhibit numerous endocrine and metabolic abnormalities. Adrenalectomy of obese rats has been shown to reduce or reverse several of these abnormalities, thereby implying that corticosterone may contribute to the expression of obesity in this animal. Furthermore, it has been shown that the circadian rhythm of plasma corticosterone is disturbed in obese Zucker rats resulting in elevated morning plasma corticosterone concentrations in obese rats as compared to lean rats. In a effort to better elucidate the mechanism of the elevated morning levels of plasma corticosterone, the metabolic clearance rate of corticosterone was determined in the morning for lean and obese male Zucker rats (12 to 20 weeks). Additionally, the biliary and urinary excretion of labeled corticosterone and/or its metabolites were determined. The metabolic clearance rate of corticosterone was significantly greater in obese rats than in their lean counterparts. Both the metabolic clearance rate and the volume of compartments significantly correlated with body weight. No correlation was found between body weight and the elimination rate constant. The increased metabolic clearance rate of obese rats appeared to be due to an increase in the physiologic distribution of corticosterone and not to an alteration in the enzymes responsible for corticosterone metabolism. It appears that the metabolic clearance rate of corticosterone in obese Zucker rats does not contribute to elevated morning concentrations of plasma corticosterone previously observed in these animals. It suggests that the adrenal corticosterone secretion rate must actually be greater than one would expect from the plasma corticosterone concentrations alone

  7. Bacterial Clearance and Cytokine Profiles in a Murine Model of Postsurgical Nosocomial Pneumonia

    OpenAIRE

    Manderscheid, Patricia A.; Bodkin, Ryan P.; Davidson, Bruce A.; Jensen, Erik; Russo, Thomas A.; Knight, Paul R.

    2004-01-01

    The development of a nosocomial pneumonia is facilitated by alterations in host innate pulmonary antibacterial defenses following surgical trauma, which can result in decreased pulmonary bacterial clearance and increased morbidity and mortality. In a murine model of postoperative nosocomial infection, surgical stress (laparotomy) decreased Escherichia coli clearance from the lungs of animals that underwent surgery. Consistent with previous studies, (i) pulmonary levels of tumor necrosis facto...

  8. International guidance on clearance criteria for application to materials containing radionuclides

    International Nuclear Information System (INIS)

    Linsley, G.

    1999-01-01

    The International Basic Safety Standards for Protection against Ionizing Radiation and for the Safety of Radiation Sources establish the conditions whereby radiation sources can be released from control. The essential principle behind this concept, termed clearance, is that the risks associated with the released source should be trivially small. The concept has been widely applied and practically applicable clearance levels have been derived for use in regulating the recycling and reuse of materials originating from the nuclear industry. Since materials released from controls may be traded between countries in the same way as any other material, it is necessary to have international agreements on acceptable levels of radioactivity in materials so as to provide a basis for regulating such movements. The International Atomic Energy Agency, in concert with other international bodies, has for many years been engaged in promoting discussions between its Member States in this subject area. International guidance has been produced and discussions are continuing towards reaching a full consensus on internationally accepted clearance levels. (author)

  9. Technetium-99m mercaptoacetyltriglycine clearance: reference values for infants and children

    Energy Technology Data Exchange (ETDEWEB)

    Schofer, O. [Department of Pediatrics, Johannes-Gutenberg University, Mainz (Germany); Koenig, G. [Department of Pediatrics, Johannes-Gutenberg University, Mainz (Germany); Bartels, U. [Department of Pediatrics, Johannes-Gutenberg University, Mainz (Germany); Bockisch, A. [Department of Nuclear Medicine, Johannes-Gutenberg University, Mainz (Germany); Piepenburg, R. [Department of Nuclear Medicine, Johannes-Gutenberg University, Mainz (Germany); Beetz, R. [Department of Pediatrics, Johannes-Gutenberg University, Mainz (Germany); Meyer, G. [Department of Nuclear Medicine, Ludwig Maximilians University, Munich (Germany); Hahn, K. [Department of Nuclear Medicine, Ludwig Maximilians University, Munich (Germany)

    1995-11-01

    Six hundred and thirty-nine clearance studies performed in children aged 7 days to 19 years utilizing technetium-99m mercaptoacetyltriglycine (MAG 3) were retrospectively analysed. Standardized conditions for the investigation included: parenteral hydration (60 ml/hxm{sup 2} body surface) in addition to normal oral fluid intake, weight-related dose of {sup 99m}Tc-MAG 3 (1 MBq/kg body weight, minimum 15 MBq) and calculation of clearance according to Bubeck et al. Of the 513 children, 169 included in this analysis could be classified as ``normal`` with regard to their renal function. Normal kidney function was judged by the following criteria: normal GFR for age, normal tubular function (absence of proteinuria and glucosuria), normal renal parenchyma (on ultrasonography, MAG 3 scan and intravenous pyelography), absence of significant obstruction and gross reflux (> grade I) no single kidney and no difference in split renal function > 20%. Results showed increasing MAG 3 clearance values for infants during the first months of life, reaching the normal range for older children and adults between 7 and 12 months. (orig.)

  10. Technetium-99m mercaptoacetyltriglycine clearance: reference values for infants and children

    International Nuclear Information System (INIS)

    Schofer, O.; Koenig, G.; Bartels, U.; Bockisch, A.; Piepenburg, R.; Beetz, R.; Meyer, G.; Hahn, K.

    1995-01-01

    Six hundred and thirty-nine clearance studies performed in children aged 7 days to 19 years utilizing technetium-99m mercaptoacetyltriglycine (MAG 3) were retrospectively analysed. Standardized conditions for the investigation included: parenteral hydration (60 ml/hxm 2 body surface) in addition to normal oral fluid intake, weight-related dose of 99m Tc-MAG 3 (1 MBq/kg body weight, minimum 15 MBq) and calculation of clearance according to Bubeck et al. Of the 513 children, 169 included in this analysis could be classified as ''normal'' with regard to their renal function. Normal kidney function was judged by the following criteria: normal GFR for age, normal tubular function (absence of proteinuria and glucosuria), normal renal parenchyma (on ultrasonography, MAG 3 scan and intravenous pyelography), absence of significant obstruction and gross reflux (> grade I) no single kidney and no difference in split renal function > 20%. Results showed increasing MAG 3 clearance values for infants during the first months of life, reaching the normal range for older children and adults between 7 and 12 months. (orig.)

  11. 78 FR 22020 - Agency Information Collection Activities: Requests for Comments; Clearance of New Approval of...

    Science.gov (United States)

    2013-04-12

    ... Control Number: 2120-XXXX. Title: Safety Awareness, Feedback, and Evaluation (SAFE) Program. Form Numbers: No FAA forms are associated with this collection. Type of Review: Clearance of a new information... Activities: Requests for Comments; Clearance of New Approval of Information Collection: Safety Awareness...

  12. 76 FR 49838 - Proposed Collection; Comment Request for Generic Clearance for the Collection of Qualitative...

    Science.gov (United States)

    2011-08-11

    ... Generic Clearance for the Collection of Qualitative Feedback on Agency Service Delivery AGENCY: Internal... of Qualitative Feedback on Agency Service Delivery. DATES: Written comments should be received on or... . SUPPLEMENTARY INFORMATION: Title: Generic Clearance for the Collection of Qualitative Feedback on Agency Service...

  13. 50 CFR 14.52 - Clearance of imported wildlife.

    Science.gov (United States)

    2010-10-01

    ... 50 Wildlife and Fisheries 1 2010-10-01 2010-10-01 false Clearance of imported wildlife. 14.52 Section 14.52 Wildlife and Fisheries UNITED STATES FISH AND WILDLIFE SERVICE, DEPARTMENT OF THE INTERIOR TAKING, POSSESSION, TRANSPORTATION, SALE, PURCHASE, BARTER, EXPORTATION, AND IMPORTATION OF WILDLIFE AND...

  14. Metabolism of oxycodone in human hepatocytes from different age groups and prediction of hepatic plasma clearance

    Directory of Open Access Journals (Sweden)

    Timo eKorjamo

    2012-01-01

    Full Text Available Oxycodone is commonly used to treat severe pain in adults and children. It is extensively metabolized in the liver in adults, but the maturation of metabolism is not well understood. Our aim was to study the metabolism of oxycodone in cryopreserved human hepatocytes from different age groups (3 days, 2 and 5 months, 4 years, adult pool and predict hepatic plasma clearance of oxycodone using these data. Oxycodone (0.1, 1 and 10 µM was incubated with hepatocytes for 4 hours, and 1 µM oxycodone also with CYP3A inhibitor ketoconazole (1 µM. Oxycodone and noroxycodone concentrations were determined at several time points with liquid chromatography-mass spectrometry. In vitro clearance of oxycodone was used to predict hepatic plasma clearance, using the well-stirred model and published physiological parameters. Noroxycodone was the major metabolite in all batches and ketoconazole inhibited the metabolism markedly in most cases. A clear correlation between in vitro oxycodone clearance and CYP3A4 activity was observed. The predicted hepatic plasma clearances were typically much lower than the published median total plasma clearance from pharmacokinetic studies. In general, this in vitro to in vivo extrapolation method provides valuable information on the maturation of oxycodone metabolism that can be utilized in the design of clinical pharmacokinetic studies in infants and young children.

  15. [Manual airway clearance techniques in adults and adolescents: What level of evidence?

    Science.gov (United States)

    Cabillic, Michel; Gouilly, Pascal; Reychler, Gregory

    2016-04-13

    The aim of this systematic literature review was to grade the levels of evidence of the most widely used manual airway clearance techniques. A literature search was conducted over the period 1995-2014 from the Medline, PEDro, ScienceDirect, Cochrane Library, REEDOC and kinedoc databases, with the following keywords: "postural drainage", "manual vibrations", "manual chest percussion", "directed cough", "increased expiratory flow", "ELTGOL", "autogenic drainage" and "active cycle of breathing technique". Two-hundred and fifty-six articles were identified. After removing duplicates and reading the titles and abstracts, 63 articles were selected, including 9 systematic reviews. This work highlights the lack of useful scientific data and the difficulty of determining levels of evidence for manual airway clearance techniques. Techniques were assessed principally with patients with sputum production (cystic fibrosis, DDB, COPD, etc.). It also shows the limited pertinence of outcome measures to quantify congestion and hence the efficacy of airway clearance techniques. The 1994 consensus conference summary table classifying airway clearance techniques according to physical mechanism provides an interesting tool for assessment, grouping together techniques having identical mechanisms of action. From the findings of the present systematic review, it appears that only ELTGOL, autogenic drainage and ACBT present levels of evidence "B". All other techniques have lower levels of evidence. II. Copyright © 2016. Published by Elsevier Masson SAS.

  16. The detailed measurement of foot clearance by young adults during stair descent.

    Science.gov (United States)

    Telonio, A; Blanchet, S; Maganaris, C N; Baltzopoulos, V; McFadyen, B J

    2013-04-26

    Foot clearance is an important variable for understanding safe stair negotiation, but few studies have provided detailed measures of it. This paper presents a new method to calculate minimal shoe clearance during stair descent and compares it to previous literature. Seventeen healthy young subjects descended a five step staircase with step treads of 300 mm and step heights of 188 mm. Kinematic data were collected with an Optotrak system (model 3020) and three non-colinear infrared markers on the feet. Ninety points were digitized on the foot sole prior to data collection using a 6 marker probe and related to the triad of markers on the foot. The foot sole was reconstructed using the Matlab (version 7.0) "meshgrid" function and minimal distance to each step edge was calculated for the heel, toe and foot sole. Results showed significant differences in minimum clearance between sole, heel and toe, with the shoe sole being the closest and the toe the furthest. While the hind foot sole was closest for 69% of the time, the actual minimum clearance point on the sole did vary across subjects and staircase steps. This new method, and the findings on healthy young subjects, can be applied to future studies of other populations and staircase dimensions. Copyright © 2013 Elsevier Ltd. All rights reserved.

  17. The Paravascular Pathway for Brain Waste Clearance: Current Understanding, Significance and Controversy

    Directory of Open Access Journals (Sweden)

    Andrew Bacyinski

    2017-11-01

    Full Text Available The paravascular pathway, also known as the “glymphatic” pathway, is a recently described system for waste clearance in the brain. According to this model, cerebrospinal fluid (CSF enters the paravascular spaces surrounding penetrating arteries of the brain, mixes with interstitial fluid (ISF and solutes in the parenchyma, and exits along paravascular spaces of draining veins. Studies have shown that metabolic waste products and solutes, including proteins involved in the pathogenesis of neurodegenerative diseases such as amyloid-beta, may be cleared by this pathway. Consequently, a growing body of research has begun to explore the association between glymphatic dysfunction and various disease states. However, significant controversy exists in the literature regarding both the direction of waste clearance as well as the anatomical space in which the waste-fluid mixture is contained. Some studies have found no evidence of interstitial solute clearance along the paravascular space of veins. Rather, they demonstrate a perivascular pathway in which waste is cleared from the brain along an anatomically distinct perivascular space in a direction opposite to that of paravascular flow. Although possible explanations have been offered, none have been able to fully reconcile the discrepancies in the literature, and many questions remain. Given the therapeutic potential that a comprehensive understanding of brain waste clearance pathways might offer, further research and clarification is highly warranted.

  18. The Paravascular Pathway for Brain Waste Clearance: Current Understanding, Significance and Controversy.

    Science.gov (United States)

    Bacyinski, Andrew; Xu, Maosheng; Wang, Wei; Hu, Jiani

    2017-01-01

    The paravascular pathway, also known as the "glymphatic" pathway, is a recently described system for waste clearance in the brain. According to this model, cerebrospinal fluid (CSF) enters the paravascular spaces surrounding penetrating arteries of the brain, mixes with interstitial fluid (ISF) and solutes in the parenchyma, and exits along paravascular spaces of draining veins. Studies have shown that metabolic waste products and solutes, including proteins involved in the pathogenesis of neurodegenerative diseases such as amyloid-beta, may be cleared by this pathway. Consequently, a growing body of research has begun to explore the association between glymphatic dysfunction and various disease states. However, significant controversy exists in the literature regarding both the direction of waste clearance as well as the anatomical space in which the waste-fluid mixture is contained. Some studies have found no evidence of interstitial solute clearance along the paravascular space of veins. Rather, they demonstrate a perivascular pathway in which waste is cleared from the brain along an anatomically distinct perivascular space in a direction opposite to that of paravascular flow. Although possible explanations have been offered, none have been able to fully reconcile the discrepancies in the literature, and many questions remain. Given the therapeutic potential that a comprehensive understanding of brain waste clearance pathways might offer, further research and clarification is highly warranted.

  19. Blanking Clearance and Punch Velocity Effects on The Sheared Edge Characteristic in Micro-Blanking of Commercially Pure Copper Sheet

    OpenAIRE

    Didin Zakaria Lubis; Ichsan Ristiawan

    2017-01-01

    This study aims to identify the influences between clearance and punch velocity on the part edge quality of blanked parts. Experiments have been conducted using material copper, punch-die clearance and punch velocity variations. In order to determine the reachable punch-die clearance and punch velocity required for blanking. The quality of the part-edge characteristics shows that higher punch velocity and decreases clearance value can improve the part-edge quality, resulting in smaller burr h...

  20. [Conservative calibration of a clearance monitor system for waste material from nuclear medicine].

    Science.gov (United States)

    Wanke, Carsten; Geworski, Lilli

    2014-09-01

    Clearance monitor systems are used for gross gamma measurements of waste potentially contaminated with radioactivity. These measurements are to make sure that legal requirements, e.g. clearance criteria according to the german radiation protection ordinance, are met. This means that measurement results may overestimate, but must not underestimate the true values. This paper describes a pragmatic way using a calibrated Cs-137 point source to generate a conservative calibration for the clearance monitor system used in the Medizinische Hochschule Hannover (MHH). The most important nuclides used in nuclear medicine are considered. The measurement result reliably overestimates the true value of the activity present in the waste. The calibration is compliant with the demands for conservativity and traceability to national standards. Copyright © 2014. Published by Elsevier GmbH.

  1. Inference of type-specific HPV transmissibility, progression and clearance rates: a mathematical modelling approach.

    Directory of Open Access Journals (Sweden)

    Helen C Johnson

    Full Text Available Quantifying rates governing the clearance of Human Papillomavirus (HPV and its progression to clinical disease, together with viral transmissibility and the duration of naturally-acquired immunity, is essential in estimating the impact of vaccination programmes and screening or testing regimes. However, the complex natural history of HPV makes this difficult. We infer the viral transmissibility, rate of waning natural immunity and rates of progression and clearance of infection of 13 high-risk and 2 non-oncogenic HPV types, making use of a number of rich datasets from Sweden. Estimates of viral transmissibility, clearance of initial infection and waning immunity were derived in a Bayesian framework by fitting a susceptible-infectious-recovered-susceptible (SIRS transmission model to age- and type-specific HPV prevalence data from both a cross-sectional study and a randomised controlled trial (RCT of primary HPV screening. The models fitted well, but over-estimated the prevalence of four high-risk types with respect to the data. Three of these types (HPV-33, -35 and -58 are among the most closely related phylogenetically to the most prevalent HPV-16. The fourth (HPV-45 is the most closely related to HPV-18; the second most prevalent type. We suggest that this may be an indicator of cross-immunity. Rates of progression and clearance of clinical lesions were additionally estimated from longitudinal data gathered as part of the same RCT. Our estimates of progression and clearance rates are consistent with the findings of survival analysis studies and we extend the literature by estimating progression and clearance rates for non-16 and non-18 high-risk types. We anticipate that such type-specific estimates will be useful in the parameterisation of further models and in developing our understanding of HPV natural history.

  2. Estimation of technetium 99m mercaptoacetyltriglycine plasma clearance by use of one single plasma sample

    International Nuclear Information System (INIS)

    Mueller-Suur, R.; Magnusson, G.; Karolinska Inst., Stockholm; Bois-Svensson, I.; Jansson, B.

    1991-01-01

    Recent studies have shown that technetium 99m mercaptoacetyltriglycine (MAG-3) is a suitable replacement for iodine 131 or 123 hippurate in gamma-camera renography. Also, the determination of its clearance is of value, since it correlates well with that of hippurate and thus may be an indirect measure of renal plasma flow. In order to simplify the clearance method we developed formulas for the estimation of plasma clearance of MAG-3 based on a single plasma sample and compared them with the multiple sample method based on 7 plasma samples. The correlation to effective renal plasma flow (ERPF) (according to Tauxe's method, using iodine 123 hippurate), which ranged from 75 to 654 ml/min per 1.73 m 2 , was determined in these patients. Using the developed regression equations the error of estimate for the simplified clearance method was acceptably low (18-14 ml/min), when the single plasma sample was taken 44-64 min post-injection. Formulas for different sampling times at 44, 48, 52, 56, 60 and 64 min are given, and we recommend 60 min as optimal, with an error of estimate of 15.5 ml/min. The correlation between the MAG-3 clearances and ERPF was high (r=0.90). Since normal values for MAG-3 clearance are not yet available, transformation to estimated ERPF values by the regression equation (ERPF=1.86xC MAG-3 +4.6) could be of clinical value in order to compare it with the normal values for ERPF given in the literature. (orig.)

  3. Error modelling and experimental validation of a planar 3-PPR parallel manipulator with joint clearances

    DEFF Research Database (Denmark)

    Wu, Guanglei; Bai, Shaoping; Kepler, Jørgen Asbøl

    2012-01-01

    This paper deals with the error modelling and analysis of a 3-PPR planar parallel manipulator with joint clearances. The kinematics and the Cartesian workspace of the manipulator are analyzed. An error model is established with considerations of both configuration errors and joint clearances. Using...

  4. 78 FR 72153 - Proposed Collection; Comment Request for Generic Clearance for the Collection of Qualitative...

    Science.gov (United States)

    2013-12-02

    ... Generic Clearance for the Collection of Qualitative Feedback on Agency Service Delivery AGENCY: Internal... of Qualitative Feedback on Agency Service Delivery. DATES: Written comments should be received on or...: Generic Clearance for the Collection of Qualitative Feedback on Agency Service Delivery. OMB Number: 1545...

  5. Planar rigid-flexible coupling spacecraft modeling and control considering solar array deployment and joint clearance

    Science.gov (United States)

    Li, Yuanyuan; Wang, Zilu; Wang, Cong; Huang, Wenhu

    2018-01-01

    Based on Nodal Coordinate Formulation (NCF) and Absolute Nodal Coordinate Formulation (ANCF), this paper establishes rigid-flexible coupling dynamic model of the spacecraft with large deployable solar arrays and multiple clearance joints to analyze and control the satellite attitude under deployment disturbance. Considering torque spring, close cable loop (CCL) configuration and latch mechanisms, a typical spacecraft composed of a rigid main-body described by NCF and two flexible panels described by ANCF is used as a demonstration case. Nonlinear contact force model and modified Coulomb friction model are selected to establish normal contact force and tangential friction model, respectively. Generalized elastic force are derived and all generalized forces are defined in the NCF-ANCF frame. The Newmark-β method is used to solve system equations of motion. The availability and superiority of the proposed model is verified through comparing with numerical co-simulations of Patran and ADAMS software. The numerical results reveal the effects of panel flexibility, joint clearance and their coupling on satellite attitude. The effects of clearance number, clearance size and clearance stiffness on satellite attitude are investigated. Furthermore, a proportional-differential (PD) attitude controller of spacecraft is designed to discuss the effect of attitude control on the dynamic responses of the whole system.

  6. Application of the concepts of exclusion, exemption and clearance. Safety guide

    International Nuclear Information System (INIS)

    2007-01-01

    The objective of this Safety Guide is to provide guidance to national authorities, including regulatory bodies, and operating organizations on the application of the concepts of exclusion, exemption and clearance as established in the International Basic Safety Standards for Protection against Ionizing Radiation and for the Safety of Radiation Sources (BSS). The Safety Guide includes specific values of activity concentration for both radionuclides of natural origin and those of artificial origin that may be used for bulk amounts of material for the purpose of applying exclusion or exemption. It also elaborates on the possible application of these values to clearance

  7. Metastatic lymph-node clearance from head and neck-epidermoid carcinomas following radiotherapy

    Energy Technology Data Exchange (ETDEWEB)

    Ohara, Kiyoshi; Tatsuzaki, Hideo; Kurosaki, Yoshihisa; Fuji, Hiroshi; Myo-Min; Itai, Yuji [Tsukuba Univ. (Japan). Dept. of Radiology; Hara, Akira; Kusakari, Jun [Tsukuba Univ. (Japan). Dept. of Otolaryngology; Ogata, Takesaburo [Tsukuba Univ. (Japan). Inst. of Clinical Medicine]|[Ibaraki Prefectural Univ. of Health Sciences (Japan). Dept. of Pathology

    1999-08-01

    Although tumor clearance is a common criterion in assessing the impact of radiotherapy (RT), it is not always reliable. Patterns of tumor clearance were determined using 91 metastatic lymph nodes (LNs) from 51 patients with head and neck tumors treated by definitive RT (61-80 Gy) or preoperative RT (43-65 Gy). Clearance rate (CR) was estimated as a daily volume decrement expressed as a ratio to the pre-RT LN volume. CR was greater for the so-called radioresponsive nasopharyngeal subgroups and more poorly differentiated than those of oral cavity and well-differentiated, respectively. Histologically, LNs that were removed following RT consisted mainly of fibrous tissues, necrotic tissues, and few cancer cells. There was no difference in CR between the cancer-cell-positive group (n=21) and the cancer-cell-negative groups (n=31). Although the CR may reflect inherent radiosensitivity of tumor cells, tumor persistence predicts the amount of oncologically inactive materials rather than that of remaining cancer cells. (orig.)

  8. Metastatic lymph-node clearance from head and neck-epidermoid carcinomas following radiotherapy

    International Nuclear Information System (INIS)

    Ohara, Kiyoshi; Tatsuzaki, Hideo; Kurosaki, Yoshihisa; Fuji, Hiroshi; Myo-Min; Itai, Yuji; Hara, Akira; Kusakari, Jun; Ogata, Takesaburo; Ibaraki Prefectural Univ. of Health Sciences

    1999-01-01

    Although tumor clearance is a common criterion in assessing the impact of radiotherapy (RT), it is not always reliable. Patterns of tumor clearance were determined using 91 metastatic lymph nodes (LNs) from 51 patients with head and neck tumors treated by definitive RT (61-80 Gy) or preoperative RT (43-65 Gy). Clearance rate (CR) was estimated as a daily volume decrement expressed as a ratio to the pre-RT LN volume. CR was greater for the so-called radioresponsive nasopharyngeal subgroups and more poorly differentiated than those of oral cavity and well-differentiated, respectively. Histologically, LNs that were removed following RT consisted mainly of fibrous tissues, necrotic tissues, and few cancer cells. There was no difference in CR between the cancer-cell-positive group (n=21) and the cancer-cell-negative groups (n=31). Although the CR may reflect inherent radiosensitivity of tumor cells, tumor persistence predicts the amount of oncologically inactive materials rather than that of remaining cancer cells. (orig.)

  9. Acute changes in intra-alveolar tooth position and local clearance of 125I from the periodontal ligament

    International Nuclear Information System (INIS)

    Edwall, B.; Berg, J.O.; Gazelius, B.; Edwall, L.; Aars, H.

    1987-01-01

    Changes in intra-alveolar tooth position and local 125 I clearance from the periodontal ligament (PDL) were monitored simultaneously in cats. Axial tooth movements, reflecting periodontal ligament volume changes, were measured with an ultrasonic transit time technique. Local blood flow changes in the PDL were studied indirectly by measuring the local clearance of 125 I. Stimulation of the cervical sympathetic trunk caused an intrusive movement of the tooth with a concomitant reduction of the 125 I-clearance. Infusion of noradrenaline induced a similar respone. Stimulation of the inferior alveolar nerve during systemic treatment with phentolamine caused an extrusive movement of the tooth with a concomitant increase in the clearance of the tracer from the PDL. Intra-arterial infusion of the vasodilator substance P mimicked that response. Fization of the tooth to the jaw bone, thus preventing an intrusive movement, did not change the reductions in clearance seen on sympathetic stimulation, indicating that this blood flow reduction was not dependent on tooth movement. A qualitative relation between PDL blood flow (as measured by local 125 I clearance) and PDL volume (as measured by tooth position) in shown. The two variables measured are suggested to reflect two aspects of blood flow in the PDL

  10. Kupffer cell complement receptor clearance function and host defense.

    Science.gov (United States)

    Loegering, D J

    1986-01-01

    Kupffer cells are well known to be important for normal host defense function. The development of methods to evaluate the in vivo function of specific receptors on Kupffer cells has made it possible to assess the role of these receptors in host defense. The rationale for studying complement receptors is based on the proposed important role of these receptors in host defense and on the observation that the hereditary deficiency of a complement receptor is associated with recurrent severe bacterial infections. The studies reviewed here demonstrate that forms of injury that are associated with depressed host defense including thermal injury, hemorrhagic shock, trauma, and surgery also cause a decrease in complement receptor clearance function. This decrease in Kupffer cell receptor clearance function was shown not to be the result of depressed hepatic blood flow or depletion of complement components. Complement receptor function was also depressed following the phagocytosis of particulates that are known to depress Kupffer cell host defense function. Endotoxemia and bacteremia also were associated with a depression of complement receptor function. Complement receptor function was experimentally depressed in uninjured animals by the phagocytosis of IgG-coated erythrocytes. There was a close association between the depression of complement receptor clearance function and increased susceptibility to the lethal effects of endotoxin and bacterial infection. These studies support the hypotheses that complement receptors on Kupffer cells are important for normal host defense and that depression of the function of these receptors impairs host defense.

  11. Two-phase deep-lung clearance in man

    International Nuclear Information System (INIS)

    Bohning, D.E.; Cohn, S.H.; Lee, H.D.; Atkins, H.L.

    1980-01-01

    For toxicological as well as physiological considerations, it is important to determine whether the long-term clearance of particles from the lungs of man takes place in more than one temporal subphase. Although long-term retention can be characterized with a single exponential, the existence of two distinct components would significantly alter estimates of overall residence times and hence potential effects of inhaled particulates. Physiological interpretations of the mechanisms of long-term particle clearance depend on the identification and quantification of such temporal subphases. A highly sensitive whole-body counter was used to measure the long-term retention of inhaled particles in man. After inhalation of 85 Sr, lung retention was monitored in eight volunteers for periods ranging from 197 to 399 days. Their pulmonary-function values fell within normal limits, and they reported no symptoms of lung disease. Four of the individuals had never smoked, and four had not smoked for a minimum of 5 years. Single exponential representation half-times for the long-term retention were comparable between the two groups and were combined to give a mean half-time of 197 +- 32 days

  12. Dynamic clearance measure to evaluate locomotor and perceptuo-motor strategies used for obstacle circumvention in a virtual environment.

    Science.gov (United States)

    Darekar, Anuja; Lamontagne, Anouk; Fung, Joyce

    2015-04-01

    Circumvention around an obstacle entails a dynamic interaction with the obstacle to maintain a safe clearance. We used a novel mathematical interpolation method based on the modified Shepard's method of Inverse Distance Weighting to compute dynamic clearance that reflected this interaction as well as minimal clearance. This proof-of-principle study included seven young healthy, four post-stroke and four healthy age-matched individuals. A virtual environment designed to assess obstacle circumvention was used to administer a locomotor (walking) and a perceptuo-motor (navigation with a joystick) task. In both tasks, participants were asked to navigate towards a target while avoiding collision with a moving obstacle that approached from either head-on, or 30° left or right. Among young individuals, dynamic clearance did not differ significantly between obstacle approach directions in both tasks. Post-stroke individuals maintained larger and smaller dynamic clearance during the locomotor and the perceptuo-motor task respectively as compared to age-matched controls. Dynamic clearance was larger than minimal distance from the obstacle irrespective of the group, task and obstacle approach direction. Also, in contrast to minimal distance, dynamic clearance can respond differently to different avoidance behaviors. Such a measure can be beneficial in contrasting obstacle avoidance behaviors in different populations with mobility problems. Copyright © 2015 Elsevier B.V. All rights reserved.

  13. Development of a computer system for support and documentation of clearance of buildings of nuclear installations - 59278

    International Nuclear Information System (INIS)

    Winkler, Christoph; Woerlen, Stefan; Thierfeldt, Stefan; Schartmann, Frank

    2012-01-01

    Clearance of buildings of nuclear installations in Germany has to comply with general requirements laid down in Section 29 of the German Radiation Protection Ordinance (RPO; Strahlenschutzverordnung), clearance levels as stipulated in Table 1 of Annex III RPO and technical guidance given in the technical standard DIN 25457. Clearance procedures are usually proposed by the licensee and are made part of a decommissioning licence after appropriate review by the authorities. The clearance procedures consist of a radiological characterisation of the various parts of the buildings, a decontamination step if necessary, followed by measurements for checking the success of decontamination, and the actual decision measurements for demonstrating compliance with clearance levels. These three steps rely on various measurement methods, selected depending on the relevant radionuclides to be measured, like sampling with subsequent gamma spectrometry (and if necessary separate evaluation of beta and alpha emitting nuclides), measurements with surface contamination monitory and in situ gamma spectrometry. For a nuclear power plant, the number of samples taken during this procedure can easily reach a few 10, 000, while the number of single measurements can reach several 100, 000 single surface measurements and several 10, 000 measurements with in situ gamma spectrometry. This large number of data together with the correct interpretation according to the valid nuclide vector, the penetration depth of the contamination, the correction for radioactive decay etc have to be managed, which is a error-prone process if carried out manually or with insufficient support by customised software. For this reason, a versatile software tool has been developed by Brenk Systemplanung GmbH that supports the operator in all aspects of clearance of buildings, based on the extensive experience with various clearance procedures in nuclear power plants that Brenk Systemplanung has carried out in the past

  14. Factors affecting lower calyceal stone clearance after Extracorporeal ...

    African Journals Online (AJOL)

    Objective: Extracorporeal shock wave lithotripsy (ESWL) is one of the most commonly used procedures to remove renal calculi from the lower calyces. The aim of this work is to study the impact of radiological, anatomical and demographic factors on stone clearance after ESWL of lower calyceal calculi. Patients and ...

  15. Pre-Departure Clearance (PDC): An Analysis of Aviation Safety Reporting System Reports Concerning PDC Related Errors

    Science.gov (United States)

    Montalyo, Michael L.; Lebacqz, J. Victor (Technical Monitor)

    1994-01-01

    Airlines operating in the United States are required to operate under instrument flight rules (EFR). Typically, a clearance is issued via voice transmission from clearance delivery at the departing airport. In 1990, the Federal Aviation Administration (FAA) began deployment of the Pre-Departure Clearance (PDC) system at 30 U.S. airports. The PDC system utilizes aeronautical datalink and Aircraft Communication and Reporting System (ACARS) to transmit departure clearances directly to the pilot. An objective of the PDC system is to provide an immediate reduction in voice congestion over the clearance delivery frequency. Participating airports report that this objective has been met. However, preliminary analysis of 42 Aviation Safety Reporting System (ASRS) reports has revealed problems in PDC procedures and formatting which have caused errors in the proper execution of the clearance. It must be acknowledged that this technology, along with other advancements on the flightdeck, is adding more responsibility to the crew and increasing the opportunity for error. The present study uses these findings as a basis for further coding and analysis of an additional 82 reports obtained from an ASRS database search. These reports indicate that clearances are often amended or exceptions are added in order to accommodate local ATC facilities. However, the onboard ACARS is limited in its ability to emphasize or highlight these changes which has resulted in altitude and heading deviations along with increases in ATC workload. Furthermore, few participating airports require any type of PDC receipt confirmation. In fact, 35% of all ASRS reports dealing with PDC's include failure to acquire the PDC at all. Consequently, this study examines pilots' suggestions contained in ASRS reports in order to develop recommendations to airlines and ATC facilities to help reduce the amount of incidents that occur.

  16. Numerical analysis of gas leakage in the piston-cylinder clearance of reciprocating compressors considering compressibility effects

    Science.gov (United States)

    Braga, V. M.; Deschamps, C. J.

    2017-08-01

    Leakage is a major source of inefficiency in low-capacity reciprocating compressors. Not only does it lower the mass flow rate provided by the compressor, reducing its volumetric efficiency, but also gives rise to outflux of energy that decreases the isentropic efficiency. Leakage in the piston-cylinder clearance of reciprocating compressors is driven by the piston motion and pressure difference between the compression chamber and the shell internal environment. In compressors adopted for domestic refrigeration, such a clearance is usually filled by a mixture of refrigerant and lubricating oil. Besides its lubricating function, the oil also acts as sealing element for the piston-cylinder clearance, and hence leakage is expected to be more detrimental to oil-free compressors. This paper presents a model based on the Reynolds equation for compressible fluid flow to predict leakage in oil-free reciprocating compressors. The model is solved throughout the compression cycle so as to assess the effect of the clearance geometry and piston velocity on leakage and compressor efficiency. The results show that compressible fluid flow formulation must be considered for predictions of gas leakage in the cylinder-piston clearance.

  17. Autogenic drainage for airway clearance in cystic fibrosis.

    Science.gov (United States)

    McCormack, Pamela; Burnham, Paul; Southern, Kevin W

    2017-10-06

    Autogenic drainage is an airway clearance technique that was developed by Jean Chevaillier in 1967. The technique is characterised by breathing control using expiratory airflow to mobilise secretions from smaller to larger airways. Secretions are cleared independently by adjusting the depth and speed of respiration in a sequence of controlled breathing techniques during exhalation. The technique requires training, concentration and effort from the individual. It is important to systematically review the evidence demonstrating that autogenic drainage is an effective intervention for people with cystic fibrosis. To compare the clinical effectiveness of autogenic drainage in people with cystic fibrosis with other physiotherapy airway clearance techniques. We searched the Cochrane Cystic Fibrosis Trials Register, compiled from electronic database searches and handsearching of journals and conference abstract books. We also searched the reference lists of relevant articles and reviews, as well as two trials registers (31 August 2017).Dtae of most recent search of the Cochrane Cystic Fibrosis Trials Register: 25 September 2017. We identified randomised and quasi-randomised controlled studies comparing autogenic drainage to another airway clearance technique or no therapy in people with cystic fibrosis for at least two treatment sessions. Data extraction and assessments of risk of bias were independently performed by two authors. The authors assessed the quality of the evidence using the GRADE system. The authors contacted two investigators for further information pertinent to their published studies. Searches retrieved 35 references to 21 individual studies, of which seven (n = 208) were eligible for inclusion. One study was of parallel design with the remaining six being cross-over in design; participant numbers ranged from 17 to 75. The total study duration varied between four days and two years. The age of participants ranged between seven and 63 years with a wide

  18. A Parametric Study of Actuator Requirements for Active Turbine Tip Clearance Control of a Modern High Bypass Turbofan Engine

    Science.gov (United States)

    Kratz, Jonathan L.; Chapman, Jeffryes W.; Guo, Ten-Huei

    2017-01-01

    The efficiency of aircraft gas turbine engines is sensitive to the distance between the tips of its turbine blades and its shroud, which serves as its containment structure. Maintaining tighter clearance between these components has been shown to increase turbine efficiency, increase fuel efficiency, and reduce the turbine inlet temperature, and this correlates to a longer time-on-wing for the engine. Therefore, there is a desire to maintain a tight clearance in the turbine, which requires fast response active clearance control. Fast response active tip clearance control will require an actuator to modify the physical or effective tip clearance in the turbine. This paper evaluates the requirements of a generic active turbine tip clearance actuator for a modern commercial aircraft engine using the Commercial Modular Aero-Propulsion System Simulation 40k (C-MAPSS40k) software that has previously been integrated with a dynamic tip clearance model. A parametric study was performed in an attempt to evaluate requirements for control actuators in terms of bandwidth, rate limits, saturation limits, and deadband. Constraints on the weight of the actuation system and some considerations as to the force which the actuator must be capable of exerting and maintaining are also investigated. From the results, the relevant range of the evaluated actuator parameters can be extracted. Some additional discussion is provided on the challenges posed by the tip clearance control problem and the implications for future small core aircraft engines.

  19. Pleural liquid clearance rate measured in awake sheep by the volume of dilution method

    International Nuclear Information System (INIS)

    Broaddus, V.C.; Wiener-Kronish, J.P.; Berthiaume, Y.; Staub, N.C.

    1986-01-01

    The authors reported 24h clearance of mock pleural effusions measured terminally in sheep. To measure effusion volume at different times in the same sheep, they injected 111 In-transferrin and measured its dilution. In 5 sheep with effusions of known sizes, the method was accurate to +/-10%. In 5 awake sheep, the authors injected 10 ml/kg of a 1% protein solution via a non-penetrating rib capsule. At 6h, the authors measured the volume by the dilution method and at 24h by direct recovery. The clearance rate in each animal was constant at 2.9-6.0%/h (average 4.8 +/- 1.3%/h). This new method gives a reliable two point clearance rate and requires fewer animals

  20. Analysis of conservativity analysis for clearance levels. Final report; Konservativitaetsanalysen bei Freigabegrenzwerten. Schlussbericht

    Energy Technology Data Exchange (ETDEWEB)

    Deckert, A; Thierfeldt, S

    1997-07-01

    When deriving clearance levels for material from nuclear installations it is necessary to proceed with a certain degree of conservativity. This can, however, differ between various sets of clearance levels leading to inconsistencies between clearance pathways. The aim of the work therefore is to compare levels of conservativity for the following two sets of clearance levels: clearance levels for disposal as conventional waste and for metallic materials for recycling/reuse. A method was developed to quantify the degree of conservativity and make it comparable. The actual and future situation for disposal of (conventional) wastes in Germany was analysed. In addition, the masses, nuclide vectors, geographical distribution etc. for slightly radioactive material being cleared for conventional disposal was analysed and modelled and the resulting dose distributions were calculated. The values for the clearance levels were taken from the 1995 recommendation by the German Commission on Radiation Protection (SSK). By using realistic scenarios, the exposure was calculated for the personnel on the landfills and for persons of the general public being exposed via groundwater pathways. It could be shown that the trivial dose range will not be exceeded even if the masses of cleared material per landfill site exceed 100 Mg/a. Because of the types and distribution of nuclear installations in Germany and because of the nuclide vectors it is therefore not necessary to limit the masses per landfill sites. Clearance levels that are determined by the exposure pathways external exposure to and the inhalation of dust by the landfill personnel show a similar level of conservativity as those for metal scrap (the reference). This means that the clearance levels for gamma emitting nuclides are not overly restrictive. The radiological model for the exposure via the groundwater pathway is much more conservative (concerning mainly beta emitting nuclides). Although radiologically justified