WorldWideScience

Sample records for sealed tube zinc

  1. Optimization of Sealed Tube Graphitization Method for Environmental C-14 Studies Using MICADAS

    Energy Technology Data Exchange (ETDEWEB)

    Rinyu, Laszlo, E-mail: rinyu@atomki.hu [Hertelendi Laboratory of Environmental Studies, Institute of Nuclear Research of the Hungarian Academy of Sciences (ATOMKI), H-4026 Debrecen (Hungary); Isotoptech Zrt., H-4025 Debrecen (Hungary); Molnar, Mihaly [Hertelendi Laboratory of Environmental Studies, Institute of Nuclear Research of the Hungarian Academy of Sciences (ATOMKI), H-4026 Debrecen (Hungary); Ion Beam Physics, ETH Zuerich, CH-8093 Zuerich (Switzerland); Major, Istvan [Hertelendi Laboratory of Environmental Studies, Institute of Nuclear Research of the Hungarian Academy of Sciences (ATOMKI), H-4026 Debrecen (Hungary); Nagy, Tamas; Veres, Mihaly [Isotoptech Zrt., H-4025 Debrecen (Hungary); Kimak, Adam [University of Debrecen, H-4032 Debrecen (Hungary); Wacker, Lukas; Synal, Hans-Arno [Ion Beam Physics, ETH Zuerich, CH-8093 Zuerich (Switzerland)

    2013-01-15

    The original sealed tube zinc reduction graphitization process was first developed for rapid low-precision measurements of biomedical tracer samples and later also applied for high precision measurements of not too old samples. In this study we tested the MICADAS (mini radiocarbon dating system [1]) radiocarbon measurements of targets prepared by sealed tube graphitization process. We found the optimal iron catalyst and reagents (TiH{sub 2} and Zn) amount whereby we can reach a relatively low background level, and minimized the overall {delta}{sup 13}C fractionation during the graphitization. Repeated measurements of normalization standards and real samples with known {sup 14}C activities were very well reproduced. Finally, we demonstrated the applicability of the sealed tube graphitization on real environmental samples covering a wide range of {sup 14}C concentrations.

  2. Pressure vessels and methods of sealing leaky tubes disposed in pressure vessels

    International Nuclear Information System (INIS)

    Larson, G.C.

    1980-01-01

    This invention relates to pressure vessels and to methods of sealing leaky tubes in them and is especially applicable to pressure vessels in the form of sheet-and-tube type heat exchangers constructed with a large number of relatively small diameter tubes grouped in a bundle. To seal off a leaky tube in such a heat exchanger an explosive activated plug in the form of a hollow metal body is used, inserted at each end of the tube to be sealed. Using the arrangement of pressure vessel and associated tube sheets and the explosive activated plug method of sealing a leaky tube as described in this invention it is claimed that distortion of the adjacent tubes and the tube sheets is reduced when the explosive activated plugs are detonated. (U.K.)

  3. Sealed ion accelerator tubes (survey)

    International Nuclear Information System (INIS)

    Voitsik, L.R.

    1985-01-01

    The first publications on developing commercial models of small-scale sealed accelerator tubes in which neutrons are generated appeared in the foreign press in 1954 to 1957; they were very brief and were advertising-oriented. The tubes were designed for neutron logging of oil wells instead of ampule neutron sources (Po + Be, Ra + Be). Later, instruments of this type began to be called neutron tubes from the resulting neutron radiation that they gave off. In Soviet Union a neutron tube was developed in 1958 in connection with the development of the pulsed neutron-neutron method of studying the geological profile of oil wells. At that time the tube developed was intended, in the view of its inventors, to replace standard isotope sources with constant neutron yield. A fairly detailed survey of neutron tubes was made in the studies. 8 refs., 8 figs

  4. The Sealed Tube Neutron Generator

    International Nuclear Information System (INIS)

    Tunnell, L.N.; Beyerle, A.; Durkee, R.; Headley, G.; Hurley, P.

    1992-01-01

    A Sealed Tube Neutron Generator (STNG) has been designed and tested at Special Technologies Laboratories (STL) in Santa Barbara, California. Unlike similar tubes that have been used for years in other applications, e.g., by the oil well logging industry, the present device was designed primarily to be part of the Associated Particle Imaging (API) system. Consequently, the size and quality of the neutron spot produced by the STNG is of primary importance. Results from initial measurements indicate that performance goals are satisfied

  5. High pressure thimble/guide tube seal fitting with built-in low pressure seal especially suitable for facilitated and more efficient nuclear reactor refueling service

    International Nuclear Information System (INIS)

    Bhatt, P.N.; Blaushield, R.M.

    1991-01-01

    This patent describes a HP/LP seal arrangement for an elongated guide tube and an elongated thimble disposed therein. The guide tube and thimble extending outwardly from the core of a nuclear reactor to a seal table where the guide tube is welded to the seal table to provide a high pressure seal relative thereto. It comprises: a tubular seal fitting disposed in alignment with the guide tube with the thimble extending therethrough on the low pressure side of the seal table; first high pressure sealing means coupling one end of the fitting to an end of the guide tube to prevent leakage from within the guide tube; inwardly facing thread means disposed adjacent the other and outer end of the seal fitting; a nut having an opening through which the thimble extends and further having outwardly facing threading in mating engagement with the fitting thread means; the fitting having a seal seat spaced longitudinally inwardly from the thread means and facing the fitting outer end and further disposed annularly about the inner surface of the fitting; deformable ring seal means; second releasable high pressure sealing means coupling the thimble to the outer end portion of the guide tube

  6. Sealing device and method for sealing fractures or leaks in wall or formation surrounding tube-shaped channel

    DEFF Research Database (Denmark)

    2014-01-01

    The sealing device (1) includes an elongated body (5) adapted to be introduced into a tube-shaped channel (2) and including a sealing fluid placement section (6) arranged between a first and a second annular flow barrier (7, 8). The elongated body further includes a sealing fluid activation secti...

  7. Study of the sealing performance of tubing adapters in gas-tight deep-sea water sampler

    Directory of Open Access Journals (Sweden)

    Huang Haocai

    2014-09-01

    Full Text Available Tubing adapter is a key connection device in Gas-Tight Deep-Sea Water Sampler (GTWS. The sealing performance of the tubing adapter directly affects the GTWS’s overall gas tightness. Tubing adapters with good sealing performance can ensure the transmission of seawater samples without gas leakage and can be repeatedly used. However, the sealing performance of tubing adapters made of different materials was not studied sufficiently. With the research discussed in this paper, the materials match schemes of the tubing adapters were proposed. With non-linear finite element contact analysis and sea trials in the South China Sea, it is expected that the recommended materials match schemes not only meet the requirements of tubing adapters' sealing performance but also provide the feasible options for the following research on tubing adapters in GTWS

  8. Study of the sealing performance of tubing adapters in gas-tight deep-sea water sampler

    Directory of Open Access Journals (Sweden)

    Haocai Huang

    2014-09-01

    Full Text Available Tubing adapter is a key connection device in Gas-Tight Deep-Sea Water Sampler (GTWS. The sealing performance of the tubing adapter directly affects the GTWS's overall gas tightness. Tubing adapters with good sealing performance can ensure the transmission of seawater samples without gas leakage and can be repeatedly used. However, the sealing performance of tubing adapters made of different materials was not studied sufficiently. With the research discussed in this paper, the materials match schemes of the tubing adapters were proposed. With non-linear finite element contact analysis and sea trials in the South China Sea, it is expected that the recommended materials match schemes not only meet the requirements of tubing adapters’ sealing performance but also provide the feasible options for the following research on tubing adapters in GTWS.

  9. Method of detecting leakage from sealing attached to pressure tube

    International Nuclear Information System (INIS)

    Tomomatsu, Ken-ichi; Hayashi, Ken-ichi.

    1990-01-01

    The present invention provides a detection method for measuring the amount of water leaked from sealings attached to the lower end of a pressure tube. That is, the lower end of the pressure tube is sealed only by a metal sealing. A capturing vessel is placed under the pressure tube for capturing the leaked water dropping from the lower end of the pressure tube and the weight of the leaked water is measured on every capturing vessels to determine the amount of the leaked water. The leakage detection method based on the weight measurement has higher accuracy compared with a conventional volume measuring method using a water level gauge as described below. For example, if the volume of the captured water is 10cc, an error of about 0.1cc is caused by the volume measuring method using the water level gauge, whereas if 10g (10cc) weight of water is measured by using an accurate balance, error is only about 10 -4 g (10 -4 cc). Accordingly, the method of the present invention can measure at an accuracy about 1000 times as high as the conventional method. (I.S.)

  10. Technique employed to seal a tube leaking in a heat exchanger of the tube type by explosives with supporting means for the adjacent tubes

    International Nuclear Information System (INIS)

    Larson, G.C.

    1978-01-01

    This invention concerns the technique employed to seal a tube leaking in a heat exchanger of the tube and tube plate type by detonating metal plugs activated by an explosive and inserted in both ends of the tube. It refers in particular to an apparatus and process in which the deformation or distortion of the adjacent tubes and tube plate ties under the effect of the explosive forces is significantly reduced [fr

  11. Development of a sealed-accelerator-tube neutron generator

    Science.gov (United States)

    Verbeke; Leung; Vujic

    2000-10-01

    Sealed-accelerator-tube neutron generators are being developed in Lawrence Berkeley National Laboratory (LBNL) for applications ranging from neutron radiography to boron neutron capture therapy and neutron activation analysis. The new generation of high-output neutron generators is based on the D-T fusion reaction, producing 14.1-MeV neutrons. The main components of the neutron tube--the ion source, the accelerator and the target--are all housed in a sealed metal container without external pumping. Thick-target neutron yield computations are performed in this paper to estimate the neutron yield of titanium and scandium targets. With an average deuteron beam current of 1 A and an energy of 120 keV, a time-averaged neutron production of approximately 10(14) n/s can be estimated for a tritiated target, for both pulsed and cw operations. In mixed deuteron/triton beam operation, a beam current of 2 A at 150 keV is required for the same neutron output. Recent experimental results on ion sources and accelerator columns are presented and discussed.

  12. Associated-particle sealed-tube neutron probe for nonintrusive inspection

    International Nuclear Information System (INIS)

    Rhodes, E.; Dickerman, C.E.

    1997-01-01

    The development and investigation of a small associated-particle sealed-tube neutron generator (APSTNG) show potential for the associated-particle method to move out of the laboratory into field applications. This paper is a review of ANL investigations of this technology. Alpha particles associated with 14-MeV neutrons generated from the D-T reaction travel in the opposite direction and are detected inside the sealed tube. Gamma-ray spectra of resulting neutron reactions in the inspected volume encompassed by the alpha-detector solid angle identify many nuclides. Flight-times determined from detection times of the gamma rays and alpha particles separate the prompt and delayed gamma-rays and can yield a separate coarse tomographic image of each identified nuclide, from a single orientation without collimation. A continuous ion beam allows data acquisition by relatively low-bandwidth electronics. When a compact sealed-tube neutron generator is used, a relatively small and easily maintainable inspection system can be developed, that is rugged enough to be transportable. Proof-of-concept laboratory experiments have been performed for simulated explosives, drugs, special nuclear materials, and chemical warfare agents. Efficient collection of maximum information from each detected neutron with low background rates can allow a much lower source intensity than pulsed accelerator methods and yield a preference for an APSTNG system, when it can provide adequate usable source intensity. Based on lessons learned with the present system, an advanced APSTNG system is being designed and built that will be transportable and yield substantial increases in neutron output and target lifetime. copyright 1997 American Institute of Physics

  13. Associated-particle sealed-tube neutron probe for nonintrusive inspection

    International Nuclear Information System (INIS)

    Rhodes, E.; Dickerman, C.E.

    1996-01-01

    The development and investigation of a small associated-particle sealed-tube neutron generator (APSTNG) show potential to allow the associated-particle method to be moved out of the laboratory into field applications. Alpha particles associated with 14 MeV neutrons generated from the D-T reaction travel in the opposite direction and are detected inside the sealed tube. Gamma-ray spectra of resulting neutron reactions in the inspected volume encompassed by the alpha- detector solid angle identify many nuclides. Flight-times determined from detection times of the gamma-rays and alpha-particles not only separate the prompt and delayed gamma-rays but can also yield a separate coarse tomographic image of each identified nuclide, from a single orientation without collimation. A continuous ion beam allows data acquisition by relatively low-bandwidth commercial electronics. This efficient collection of maximum information from each detected neutron by the associated-particle method can allow a much lower source intensity than pulsed accelerator methods, provided a sufficient usable signal rate is obtained. When this method is coupled with a compact sealed-tube neutron generator, a relatively small, inexpensive, reliable, and easily maintainable inspection system can be developed, that is rugged enough to be transportable. Proof-of- concept laboratory experiments have been performed for simulated explosives, drugs, special nuclear materials, and chemical warfare agents. Based on lessons learned with the present APSTNG system, an advanced APSTNG system is being designed and built that will be transportable, yield a substantial neutron output increase, and provide a substantially improved target lifetime

  14. Indications and complications of tube thoracostomy with improvised underwater seal bottles

    Directory of Open Access Journals (Sweden)

    Sunday A Edaigbini

    2014-01-01

    Full Text Available Background: Tube thoracostomy is a lifesaving and frequently performed procedure in hospitals where the expertise and necessary tools are available. Where the ideal drainage receptacle is unavailable, the underwater seal device can be improvised with bottled water plastic can especially in emergency situations. Aims and Objectives: To determine the frequencies of the various indications and complications of tube thoracostomy with improvised underwater seal. Materials and Methods: A cross-sectional study with a structured proforma was used for assessment over a 3-year period (May 2010-April 2013. The proforma was filled at the time of the procedure by the performing surgeon and patients were followed up with serial chest X-rays until certified cured. A 1.5 L bottled water container was used as the underwater seal receptacle. The data was analysed with SPSS 15 software program. Results: A total of 167 patients were managed. There were 106 (63.5% males and 61 (36.5% females. The mean age was 34.85 ± 16.72 with a range of 1-80 years. The most frequent indication was for malignant/paramalignant effusion, 46 (27.5%. Others were trauma, 44 (26.3%, Parapneumonic effusion, 20 (12%, postthoracotomy 14 (8.4%, empyema thoracis 12 (7.2%, heart disease and tuberculous effusion 11 (6.6% each, pneumothorax 8 (4.8% and misdiagnosis 1 (0.6%. A hundred and one (60.5% of the procedures were performed by registrars, 41 (24.6% by consultants, house officers 15 (9% and senior registrars 10 (6%. The overall complication rate was 16.8% with the more frequent complications been empyema (5.6% and pneumothorax (3.6%. The average duration of tube placement was 13.02 ± 12.362 days and range of 1-110 days. Conclusion : Tube thoracostomy can be a relatively safe procedure with acceptable complication rates even with improvised underwater seal drainage bottles.

  15. Rotary plug seal

    International Nuclear Information System (INIS)

    Ito, Koji; Abiko, Yoshihiro.

    1981-01-01

    Purpose: To enable fuel exchange even upon failure of regular seals and also to enable safety seal exchange by the detection of the reduction in the contact pressure of a rotary plug seal. Constitution: If one of a pair of regular tube seals for the rotary plug is failed during ordinary operation of a FBR type reactor, the reduction in the contact pressure of the seal to the plug gibbousness is detected by a pressure gauge and a solenoid valve is thereby closed. Thus, a back-up-tube seal provided above or below the tube seal is press-contacted by way of argon gas to the gibbousness to enter into operation state and lubricants are supplied from an oil tank. In such a structure, the back-up-tube seal is operated before the failure of the tube seal to enable to continue the fuel exchange work, as well as safety exchange for the tube seal. (Moriyama, K.)

  16. Ferrules seals

    Science.gov (United States)

    Smith, J.L.

    1984-07-10

    A device is provided for sealing an inner tube and an outer tube without excessively deforming the tubes. The device includes two ferrules which cooperate to form a vacuum-tight seal between the inner tube and outer tube and having mating surfaces such that overtightening is not possible. 3 figs.

  17. Multisample conversion of water to hydrogen by zinc for stable isotope determination

    Science.gov (United States)

    Kendall, C.; Coplen, T.B.

    1985-01-01

    Two techniques for the conversion of water to hydrogen for stable isotope ratio determination have been developed that are especially suited for automated multisample analysis. Both procedures involve reaction of zinc shot with a water sample at 450 ??C. in one method designed for water samples in bottles, the water is put in capillaries and is reduced by zinc in reaction vessels; overall savings in sample preparation labor of 75% have been realized over the standard uranium reduction technique. The second technique is for waters evolved under vacuum and is a sealed-tube method employing 9 mm o.d. quartz tubing. Problems inherent with zinc reduction include surface inhomogeneity of the zinc and exchange of hydrogen both with the zinc and with the glass walls of the vessels. For best results, water/zinc and water/glass surface area ratios of vessels should be kept as large as possible.

  18. The development of an auto-sealing system using an electrically shrinkable tube under a low-pressure condition

    Energy Technology Data Exchange (ETDEWEB)

    Okano, Yoshihiro; Kitagawa, Takao [NKK Corp, Tsu, Mie (Japan); Shoji, Norio [NKK Corp., Yokohama (Japan); Namioka, Toshiyuki [Nippon Kokan Koji Corp., Yokohama (Japan). Research and Development Dept.; Komura, Minoru [Nitto Denko Corp., Fukaya, Saitama (Japan)

    1997-04-01

    This article describes the development of a system to create high quality, automatic sealing of field joints of polyethylene coated pipelines. The system uses a combination of an electrically heated shrinkable tube and a low-pressure chamber. The self-heating shrinkable tube includes electric heater wires that heat when connected to electricity. A method was developed to eliminate air trapped between the tube and the steel pipe by shrinking the tube under a low-pressure condition. The low-pressure condition was automatic and easily attained by using a vacuum chamber. It was verified that the system produced high quality sealing of the field joints.

  19. Cadmium, mercury, zinc and selenium in ringed seals (Phoca hispida from Greenland and Svalbard

    Directory of Open Access Journals (Sweden)

    Run Dietz

    1998-06-01

    Full Text Available Muscle, liver, and kidney tissue from 456 ringed seals (Phoca hispida from eight areas in Greenland were analysed for cadmium, mercury, zinc and selenium. In general, cadmium concentrations were high in liver and kidney tissue, with geometric means of 7.79 and 33.5 μg/g (all data on wet weight basis, respectively. Muscle levels were considerably lower, at 0.067 μg/g. The concentration of mercury was relatively high in liver tissue with a geometric mean of 2.59 μg/g. Muscle and kidney mercury levels were somewhat lower, with geometric means of 0.210 and 0.956 μg/g, respectively. Cadmium and mercury levels were strongly dependent upon age and sampling area, as well as the interaction combinations, indicating that the accumulation of cadmium and mercury varies with age and area. Mercury accumulated in all three tissues throughout life, whereas cadmium in liver and kidneys peaked in the age group 5-10 years old where after it dropped significantly. Cadmium levels showed a tendency towards higher concentrations in the northern municipalities, which may be due to the higher cadmium levels in certain prey items in the northern areas. Mercury levels were higher in seals from East Greenland compared to West Greenland. Variations in feeding habits probably explain some of the differences in levels of cadmium and mercury in ringed seals from different geographical areas. Cadmium concentrations were correlated (both pairwise and partial in the three organs. This was true for mercury as well, whereas only half of the combinations were significant for zinc and selenium. Cadmium was strongly correlated to mercury in all three tissues and zinc only in liver and kidneys. Mercury was only correlated to selenium in liver and not to zinc. High concentrations of cadmium were found in the bile from 58 ringed seals, and were about 10-fold higher than in muscle. The concentration of mercury in bile was relatively low, being only one third of the

  20. Place Atrium to Water Seal (PAWS): Assessing Wall Suction Versus No Suction for Chest Tubes After Open Heart Surgery.

    Science.gov (United States)

    Kruse, Tamara; Wahl, Sharon; Guthrie, Patricia Finch; Sendelbach, Sue

    2017-08-01

    Traditionally chest tubes are set to -20 cm H 2 O wall suctioning until removal to facilitate drainage of blood, fluid, and air from the pleural or mediastinal space in patients after open heart surgery. However, no clear evidence supports using wall suction in these patients. Some studies in patients after pulmonary surgery indicate that using chest tubes with a water seal is safer, because this practice decreases duration of chest tube placement and eliminates air leaks. To show that changing chest tubes to a water seal after 12 hours of wall suction (intervention) is a safe alternative to using chest tubes with wall suction until removal of the tubes (usual care) in patients after open heart surgery. A before-and-after quality improvement design was used to evaluate the differences between the 2 chest tube management approaches in chest tube complications, output, and duration of placement. A total of 48 patients received the intervention; 52 received usual care. The 2 groups (intervention vs usual care) did not differ significantly in complications (0 vs 2 events; P = .23), chest tube output (H 1 = 0.001, P = .97), or duration of placement (median, 47 hours for both groups). Changing chest tubes from wall suction to water seal after 12 hours of wall suction is a safe alternative to using wall suctioning until removal of the tubes. ©2017 American Association of Critical-Care Nurses.

  1. P-proteins in Arabidopsis are heteromeric structures involved in rapid sieve tube sealing.

    Science.gov (United States)

    Jekat, Stephan B; Ernst, Antonia M; von Bohl, Andreas; Zielonka, Sascia; Twyman, Richard M; Noll, Gundula A; Prüfer, Dirk

    2013-01-01

    Structural phloem proteins (P-proteins) are characteristic components of the sieve elements in all dicotyledonous and many monocotyledonous angiosperms. Tobacco P-proteins were recently confirmed to be encoded by the widespread sieve element occlusion (SEO) gene family, and tobacco SEO proteins were shown to be directly involved in sieve tube sealing thus preventing the loss of photosynthate. Analysis of the two Arabidopsis SEO proteins (AtSEOa and AtSEOb) indicated that the corresponding P-protein subunits do not act in a redundant manner. However, there are still pending questions regarding the interaction properties and specific functions of AtSEOa and AtSEOb as well as the general function of structural P-proteins in Arabidopsis. In this study, we characterized the Arabidopsis P-proteins in more detail. We used in planta bimolecular fluorescence complementation assays to confirm the predicted heteromeric interactions between AtSEOa and AtSEOb. Arabidopsis mutants depleted for one or both AtSEO proteins lacked the typical P-protein structures normally found in sieve elements, underlining the identity of AtSEO proteins as P-proteins and furthermore providing the means to determine the role of Arabidopsis P-proteins in sieve tube sealing. We therefore developed an assay based on phloem exudation. Mutants with reduced AtSEO expression levels lost twice as much photosynthate following injury as comparable wild-type plants, confirming that Arabidopsis P-proteins are indeed involved in sieve tube sealing.

  2. P-proteins in Arabidopsis are heteromeric structures involved in rapid sieve tube sealing

    Directory of Open Access Journals (Sweden)

    Stephan B Jekat

    2013-07-01

    Full Text Available Structural phloem proteins (P-proteins are characteristic components of the sieve elements in all dicotyledonous and many monocotyledonous angiosperms. Tobacco P-proteins were recently evidenced to be encoded by the widespread SEO gene family, and tobacco SEO proteins were shown to be directly involved in sieve tube sealing thus preventing the loss of photosynthate. Analysis of the two Arabidopsis SEO proteins (AtSEOa and AtSEOb indicated that the corresponding P-protein subunits do not act in a redundant manner. However, there are still pending questions regarding the interaction properties and specific functions of AtSEOa and AtSEOb as well as the general function of structural P-proteins in Arabidopsis. In this study, we characterized the Arabidopsis P-proteins in more detail. We used in planta bimolecular fluorescence complementation assays to confirm the predicted heteromeric interactions between AtSEOa and AtSEOb. Arabidopsis mutants depleted for one or both AtSEO proteins lacked the typical P-protein structures normally found in sieve elements, underlining the identity of AtSEO proteins as P-proteins and furthermore providing the means to determine the role of Arabidopsis P-proteins in sieve tube sealing. We therefore developed an assay based on phloem exudation. Mutants with reduced AtSEO expression levels lost twice as much photosynthate following injury as comparable wild-type plants, confirming that Arabidopsis P-proteins are indeed involved in sieve tube sealing. 

  3. A simple method for preparing superconducting FeSe pellets without sealing in evacuated silica tubes

    DEFF Research Database (Denmark)

    Grivel, Jean-Claude

    2017-01-01

    Superconducting tetragonal FeSe pellets were made by reacting mixtures of elemental Fe and Se powders in argon atmosphere without sealing in evacuated silica tubes. A simple tube furnace has been used. Although the tube's material consisted of quartz, an alumina tube could be used as well. X......-ray pure samples with onset of superconducting transition between 8.0K and 8.5K were obtained under specific heat treatment conditions. Residual, unreacted Fe particles could be virtually eliminated through prolonged annealing. A key factor for the synthesis of good samples consists in using processing...

  4. Development of a sealing process of capsules for surveillance test tubes of the vessel in nuclear power plants

    International Nuclear Information System (INIS)

    Romero C, J.; Fernandez T, F.; Perez R, N.; Rocamontes A, M.; Garcia R, R.

    2007-01-01

    The surveillance capsule is composed by the support, three capsules for impact test tubes, five capsules for tension test tubes and one porta dosemeters. The capsules for test tubes are of two types: rectangular capsule for Charpy test tubes and cylindrical capsule for tension test tubes. This work describes the development of the welding system to seal the capsules for test tubes that should contain helium of ultra high purity to a pressure of 1 atmosphere. (Author)

  5. Emergency transfer tube closure and process for sealing transfer tube under emergency conditions

    International Nuclear Information System (INIS)

    Hardin, R.T. Jr.; Marshall, J.R.

    1987-01-01

    In a nuclear fuel reactor well that includes a transfer tube projecting outwardly from wall thereof, the transfer tube is described having a first closure assembly. The transfer tube has a circumferential flange extending outwardly laterally therefrom, an emergency transfer tube closure therefor comprising; a pair of elongated, vertically-extending U-shaped guides, one U-shaped guide disposed laterally on each side of the transfer tube, each of the U-shaped guides comprising a base and laterally extending flanges thereon, the U-shaped guides having their open ends facing each other, a closure plate, having a surface facing the circumferential flange greater in area than the area circumscribed by the outer circumference of the circumferential flange, vertically disposed the U-shaped guides, the closure plate normally being disposed in a vertical plane just slightly in front of the vertical plane of the circumferential flange, two pairs of rollers, one pair of which is rotatably mounted on each side of the closure plate adjacent the U-shaped guides, riding on the inner portion of each of the flanges of each of the U-shaped guides. Each of the U-shaped guides is provided with a pair of spatially disposed openings on a flange thereof adjacent the wall of the nuclear fuel reactor well, each of the pairs of openings being disposed on each of the U-shaped guides a distance equal to the distance between the center lines of the corresponding pair of rollers riding within the U-shaped guides, each of the openings being sufficiently large to receive a corresponding roller of the pairs of rollers in the U-shaped guides. The openings is shaped on the flanges of the U-shaped guides so that when the pairs of rollers are disposed therein, the face of the closure plate will be in sealing engagement with the circumferential flange of the transfer tube

  6. Status of zinc injection in PWRs

    Energy Technology Data Exchange (ETDEWEB)

    Bergmann, C.A. [Westinghouse Electric Co., Pittsburgh, PA (United States)

    1995-03-01

    Based on laboratory and other studies, it was concluded that zinc addition in a PWR primary coolant should result in reduced Alloy 600 PWSCC and general corrosion rates of the materials of construction. Because of these positive results, a Westinghouse Owner`s Subgroup, EPRI, and Westinghouse provided funds to continue the development and application of zinc in an operating plant. As part of the program, Southern Operating Nuclear Company agreed to operate the Farley 2 plant with zinc addition as a demonstration test of the effectiveness of zinc. Since zinc is incorporated in the corrosion oxide film on the primary system surfaces and Farley 2 is a mature plant, it was estimated that about 10 kgs of zinc would be needed to condition the plant before an equilibrium value in the coolant would be reached. The engineered aspects of a Zinc Addition and Monitoring System (ZAMS) considered such items as the constitutents, location, sizing and water supply of the ZAMS. Baseline data such as the PWSCC history of the Alloy 600 steam generator tubing, fuel oxide thickness, fuel crud deposits, radiation levels, and RCP seal leak-off rates were obtained before zinc addition is initiated. This presentation summarizes some of the work performed under the program, and the status of zinc injection in the Farley 2 plant.

  7. Radioactive waste sealing container

    International Nuclear Information System (INIS)

    Tozawa, S.; Kitamura, T.; Sugimoto, S.

    1984-01-01

    A low- to medium-level radioactive waste sealing container is constructed by depositing a foundation coating consisting essentially of zinc, cadmium or a zinc-aluminum alloy over a steel base, then coating an organic synthetic resin paint containing a metal phosphate over the foundation coating, and thereafter coating an acryl resin, epoxy resin, and/or polyurethane paint. The sealing container can consist of a main container body, a lid placed over the main body, and fixing members for clamping and fixing the lid to the main body. Each fixing member may consist of a material obtained by depositing a coating consisting essentially of cadmium or a zinc-aluminum alloy over a steel base

  8. O-Ring sealing arrangements for ultra-high vacuum systems

    Science.gov (United States)

    Kim, Chang-Kyo; Flaherty, Robert

    1981-01-01

    An all metal reusable O-ring sealing arrangement for sealing two concentric tubes in an ultra-high vacuum system. An O-ring of a heat recoverable alloy such as Nitinol is concentrically positioned between protruding sealing rings of the concentric tubes. The O-ring is installed between the tubes while in a stressed martensitic state and is made to undergo a thermally induced transformation to an austenitic state. During the transformation the O-ring expands outwardly and contracts inwardly toward a previously sized austenitic configuration, thereby sealing against the protruding sealing rings of the concentric tubes.

  9. Stagnations of increasing trends in negative pressure with repeated cavitation in water/metal Berthelot tubes as a result of mechanical sealing

    International Nuclear Information System (INIS)

    Hiro, Kazuki; Ohde, Yoshihito; Tanzawa, Yasutoshi

    2003-01-01

    To investigate effects of mechanical sealing on negative pressures in water/metal tube Berthelot systems, trends in negative pressure are observed through runs of temperature cycles below 90 deg. C in two systems made of metals having small amounts of gas inclusions. The first system is a pre-degassed all-stainless-steel tube/plug system. The steel is a special product for vacuum engineering. The second is the same tube sealed with plugs made of silver solidified one-dimensionally in a vacuum furnace. A new type of trend, stagnation for intermediate cycles is found in both systems so long as sealing distortion of each plug is small in amount. The stagnation period for the first system is longer than that for the second one. A metallurgical mechanism of a gas-being-replenished crevice model is proposed: distorted parts of metals undergo heat-treatment during runs of temperature cycles, and the heat-treatment enhances the rates of impurity gas transports to crevices on the metal surface where cavitation occurs, and the transport causes the stagnation for cycles during which the rates are still high

  10. Zinc oxide nano-particles as sealer in endodontics and its sealing ability

    Directory of Open Access Journals (Sweden)

    Maryam Javidi

    2014-01-01

    Full Text Available Aims: The aim of this study was to evaluate the sealing ability of new experimental nano-ZOE-based sealer. Settings and Design: Three types of nano-ZOE-based sealer (calcined at different temperatures of 500, 600 and 700°C with two other commercially available sealers (AH26 and micro-sized zinc oxide eugenol sealer were used. Materials and Methods: Zinc oxide nano-particles were synthesized by a modified sol-gel method. The structure and morphology of the prepared powders were characterized using x-ray diffraction (XRD and transmission electron microscopy (TEM techniques. The instrumented canals of 60 single-rooted teeth were divided into five groups (n = 10, with the remaining ten used as controls. The canals were filled with gutta-percha using one of the materials mentioned above as sealer. After 3, 45 and 90 days, the samples were connected to a fluid filtration system. Statistical Analysis Used: The data were analyzed using Student′s t-test. Results: The XRD patterns and TEM images revealed that all the synthesized powders had hexagonal wurtzite structures with an average particle size of about 30-60 nm at different calcination temperatures. Microleakage in AH26 groups was significantly more than that in three groups of ZnO nano-particles at all the three evaluation intervals. Apical microleakage of ZnO micro-powders was significantly more than that of all the materials, but the sealing ability of ZnO nano-powder sealers did not differ significantly. Conclusion: The results of this study showed that the synthesized ZnO nano-powder sealers are suitable for use as a nano-sealer in root canal therapy to prevent leakage; however, further studies should be carried out to verify their safety.

  11. Associated-particle sealed-tube neutron probe: Detection of explosives, contraband, and nuclear materials

    International Nuclear Information System (INIS)

    Rhodes, E.; Dickerman, C.E.

    1996-01-01

    Continued research and development of the APSTNG shows the potential for practical field use of this technology for detection of explosives, contraband, and nuclear materials. The APSTNG (associated-particle sealed-tube generator) inspects the item to be examined using penetrating 14-MeV neutrons generated by the deuterium-tritium reaction inside a compact accelerator tube. An alpha detector built into the sealed tube detects the alpha-particle associated with each neutron emitted in a cone encompassing the volume to be inspected. Penetrating high-energy gamma-rays from the resulting neutron reactions identify specific nuclides inside the volume. Flight-times determined from the detection times of gamma-rays and alpha-particles separate the prompt and delayed gamma-ray spectra and allow a coarse 3-D image to be obtained of nuclides identified in the prompt spectrum. The generator and detectors can be on the same side of the inspected object, on opposite sides, or with intermediate orientations. Thus, spaces behind walls and other confined regions can be inspected. Signals from container walls can be discriminated against using the flight-time technique. No collimators or shielding are required, the neutron generator is relatively small, and commercial-grade electronics are employed. The use of 14-MeV neutrons yields a much higher cross-section for detecting nitrogen than that for systems based on thermal-neutron reactions alone, and the broad range of elements with significant 14-MeV neutron cross-sections extends explosives detection to other elements including low-nitrogen compounds, and allows detection of many other substances. Proof-of-concept experiments have been successfully performed for conventional explosives, chemical warfare agents, cocaine, and fissionable materials

  12. Pressure tube reactor

    International Nuclear Information System (INIS)

    Susuki, Akira; Murata, Shigeto; Minato, Akihiko.

    1993-01-01

    In a pressure tube reactor, a reactor core is constituted by arranging more than two units of a minimum unit combination of a moderator sealing pipe containing a calandria tube having moderators there between and a calandria tube and moderators. The upper header and a lower header of the calandria tank containing moderators are communicated by way of the moderator sealing tube. Further, a gravitationally dropping mechanism is disposed for injecting neutron absorbing liquid to a calandria gas injection portion. A ratio between a moderator volume and a fuel volume is defined as a function of the inner diameter of the moderator sealing tube, the outer diameter of the calandria tube and the diameter of fuel pellets, and has no influence to intervals of a pressure tube lattice. The interval of the pressure tube lattice is enlarged without increasing the size of the pressure tube, to improve production efficiency of the reactor and set a coolant void coefficient more negative, thereby enabling to improve self controllability and safety. Further, the reactor scram can be conducted by injecting neutron absorbing liquid. (N.H.)

  13. Pool gateway seal

    International Nuclear Information System (INIS)

    Starr, J.A.; Steinert, L.A.

    1983-01-01

    A device for sealing a gateway between interconnectable pools in a nuclear facility comprising a frame supporting a liquid impermeable sheet positioned in a u-shaped gateway between the pools. An inflatable tube carried in a channel in the periphery of the frame and adjoining the gateway provides a seal therebetween when inflated. A restraining arrangement on the bottom edge of the frame is releasably engagable with an adjacent portion of the gateway to restrict the movement of the frame in the u-shaped gateway upon inflation of the tube, thereby enhancing the seal. The impermeable sheet is formed of an elastomer and thus is conformable to a liquid permeable supportive wall upon application of liquid pressure to the side of the sheet opposite the wall

  14. Zinc-chelation contributes to the anti-angiogenic effect of ellagic acid on inhibiting MMP-2 activity, cell migration and tube formation.

    Directory of Open Access Journals (Sweden)

    Sheng-Teng Huang

    Full Text Available BACKGROUND: Ellagic acid (EA, a dietary polyphenolic compound, has been demonstrated to exert anti-angiogenic effect but the detailed mechanism is not yet fully understood. The aim of this study was to investigate whether the zinc chelating activity of EA contributed to its anti-angiogenic effect. METHODS AND PRINCIPAL FINDINGS: The matrix metalloproteinases-2 (MMP-2 activity, a zinc-required reaction, was directly inhibited by EA as examined by gelatin zymography, which was reversed dose-dependently by adding zinc chloride. In addition, EA was demonstrated to inhibit the secretion of MMP-2 from human umbilical vein endothelial cells (HUVECs as analyzed by Western blot method, which was also reversed by the addition of zinc chloride. Reversion-inducing cysteine-rich protein with Kazal motifs (RECK, known to down-regulate the MMP-2 activity, was induced by EA at both the mRNA and protein levels which was correlated well with the inhibition of MMP-2 activity. Interestingly, zinc chloride could also abolish the increase of EA-induced RECK expression. The anti-angiogenic effect of EA was further confirmed to inhibit matrix-induced tube formation of endothelial cells. The migration of endothelial cells as analyzed by transwell filter assay was suppressed markedly by EA dose-dependently as well. Zinc chloride could reverse these two effects of EA also in a dose-dependent manner. Since magnesium chloride or calcium chloride could not reverse the inhibitory effect of EA, zinc was found to be involved in tube formation and migration of vascular endothelial cells. CONCLUSIONS/SIGNIFICANCE: Together these results demonstrated that the zinc chelation of EA is involved in its anti-angiogenic effects by inhibiting MMP-2 activity, tube formation and cell migration of vascular endothelial cells. The role of zinc was confirmed to be important in the process of angiogenesis.

  15. Effect of cultural conditions on the seed-to-seed growth of Arabidopsis and Cardamine - A study of growth rates and reproductive development as affected by test tube seals

    Science.gov (United States)

    Hoshizaki, T.

    1982-01-01

    The effects of test tube seals on the growth, flowering, and seed pod formation of Arabidopsis thaliana (L.) Heynh., mouse ear cress, and Cardamine oligosperma Nutt, bitter cress, are studied in order to assess the conditions used in weightlessness experiments. Among other results, it is found that the growth (height) and flowering (date of bud appearance) were suppressed in mouse ear cress in tubes sealed with Saran. Seed pod formation which occurred by day 45 in open-to-air controls, was still lacking in the sealed plants even up to day 124. The growth and flowering of bitter cress were also suppressed by the Saran seal, although up to day 55 the Saran-sealed plants were taller. It is suggested that atmospheric composition was the cause of the suppression of growth, flowering, and seed pod development in these plants, since the mouse ear cress renewed their growth and then set seed pods after the Saran seal was ruptured.

  16. Grooved tube plug rolls in

    International Nuclear Information System (INIS)

    Krausser, P.

    1991-01-01

    The removable plugs used to date by the Power Generation Group (KWU) of Siemens to seal defective steam generator tubes have a good track record. Their sealing principle is based on the elastic tensioning of three seal disks against the inside wall of the tube. Now a further removable plug is available -a roll-in plug with a metal-coated surface. It is particularly suitable for use in the roller-expanded zone of the tubes at the tube sheet. The plugs can be used in both Siemens-KWU steam generators and in steam generators manufactured in compliance with the guidelines of the ASME Code. (author)

  17. Pyrotechnic Tubing Connector

    Science.gov (United States)

    Graves, Thomas J.; Yang, Robert A.

    1988-01-01

    Tool forms mechanical seal at joint without levers or hydraulic apparatus. Proposed tool intended for use in outer space used on Earth by heavily garbed workers to join tubing in difficult environments. Called Pyrotool, used with Lokring (or equivalent) fittings. Piston slides in cylinder when pushed by gas from detonating pyrotechnic charge. Impulse of piston compresses fittings, sealing around butting ends of tubes.

  18. Separately removable tubes in heavy duty heat exchanger assemblies

    International Nuclear Information System (INIS)

    Neudeck, G.T.

    1980-01-01

    The invention is directed to removable heat exchanger tube assemblies in heavy duty equipment radiators in which the tubes are each separately removable if they become defective in service. An inwardly facing annular ledge or abutment is molded into the inside diameter of each upper and lower sealing member to receive the respective ends of the tubes and prevent vertical movement of the tubes in service. A flange or shoulder is also provided on the lower portions of each tube and engages the inside of the lower sealing member to further restrain downward movement of the tubes in service. Each tube may be removed by pushing the tube upwardly to overcome the upper ledge abutment and thereby lift the tube free of the lower seal. Each tube may then be removed sidewise from the radiator. Variations of the removable sealing arrangement can be made and are described herein

  19. Development of Mechanical Sealing and Laser Welding Technology to Instrument Thermocouple for Nuclear Fuel Test Rod

    Energy Technology Data Exchange (ETDEWEB)

    Joung, Chang-Young; Ahn, Sung-Ho; Hong, Jin-Tae; Kim, Ka-Hye; Huh, Sung-Ho [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of)

    2015-05-15

    Zircaloy-4 of the nuclear fuel test rod, AISI 316L of the mechanical sealing parts, and the MI (mineral insulated) cable at a thermocouple instrumentation are hetero-metals, and are difficult to weld to dissimilar materials. Therefore, a mechanical sealing method to instrument the thermocouple should be conducted using two kinds of sealing process as follows: One is a mechanical sealing process using Swagelok, which is composed of sealing components that consists of an end-cap, a seal tube, a compression ring and a Swagelok nut. The other is a laser welding process used to join a seal tube, and an MI cable, which are made of the same material. The mechanical sealing process should be sealed up with the mechanical contact compressed by the strength forced between a seal tube and an end-cap, and the laser welding process should be conducted to have no defects on the sealing area between a seal tube and an MI cable. Therefore, the mechanical sealing and laser welding techniques need to be developed to accurately measure the centerline temperature of the nuclear fuel test rod in an experimental reactor. The mechanical sealing and laser welding tests were conducted to develop the thermocouple instrumentation techniques for the nuclear fuel test rod. The optimum torque value of a Swagelok nut to seal the mechanical sealing part between the end-cap and seal tube was established through various torque tests using a torque wrench. The optimum laser welding conditions to seal the welding part between a seal tube and an MI cable were obtained through various welding tests using a laser welding system.

  20. Development of Mechanical Sealing and Laser Welding Technology to Instrument Thermocouple for Nuclear Fuel Test Rod

    International Nuclear Information System (INIS)

    Joung, Chang-Young; Ahn, Sung-Ho; Hong, Jin-Tae; Kim, Ka-Hye; Huh, Sung-Ho

    2015-01-01

    Zircaloy-4 of the nuclear fuel test rod, AISI 316L of the mechanical sealing parts, and the MI (mineral insulated) cable at a thermocouple instrumentation are hetero-metals, and are difficult to weld to dissimilar materials. Therefore, a mechanical sealing method to instrument the thermocouple should be conducted using two kinds of sealing process as follows: One is a mechanical sealing process using Swagelok, which is composed of sealing components that consists of an end-cap, a seal tube, a compression ring and a Swagelok nut. The other is a laser welding process used to join a seal tube, and an MI cable, which are made of the same material. The mechanical sealing process should be sealed up with the mechanical contact compressed by the strength forced between a seal tube and an end-cap, and the laser welding process should be conducted to have no defects on the sealing area between a seal tube and an MI cable. Therefore, the mechanical sealing and laser welding techniques need to be developed to accurately measure the centerline temperature of the nuclear fuel test rod in an experimental reactor. The mechanical sealing and laser welding tests were conducted to develop the thermocouple instrumentation techniques for the nuclear fuel test rod. The optimum torque value of a Swagelok nut to seal the mechanical sealing part between the end-cap and seal tube was established through various torque tests using a torque wrench. The optimum laser welding conditions to seal the welding part between a seal tube and an MI cable were obtained through various welding tests using a laser welding system

  1. Testing of neutron-irradiated ceramic-to-metal seals

    International Nuclear Information System (INIS)

    Brown, R.D.; Clinard, F.W. Jr.; Lopez, M.R.; Martinez, H.; Romero, T.J.; Cook, J.H.; Barr, H.N.; Hittman, F.

    1990-01-01

    This paper reports on ceramic-to-metal seals prepared by sputtering a titanium metallizing layer onto ceramic disks and then brazing to metal tubes. The ceramics used were alumina, MACOR, spinel, AlON, and a mixture of Al 2 O 3 and Si 3 N 4 . Except for the MACOR, which was brazed to a titanium tube, the ceramics were brazed to niobium tubes. The seals were leak tested and then sent to Los Alamos National Laboratory, where they were irradiated using the spallation neutron source at the Los Alamos Meson Physics Facility. Following irradiation for ∼ 90 days to a fluence of 2.8 x 10 23 n/m 2 , the samples were moved to hot cells and again leak tested. Only the MACOR samples showed any measurable leaks. One set of samples was then pressurized to 6.9 MPa (1000 psi) and subsequently leak tested. No leaks were found. Bursting the seals required hydrostatic pressures of at least 34 MPa (5000 psi). The high seal strength and few leaks indicate that ceramic-to-metal seals can resist radiation-induced degradation

  2. Tube plug

    International Nuclear Information System (INIS)

    Zafred, P. R.

    1985-01-01

    The tube plug comprises a one piece mechanical plug having one open end and one closed end which is capable of being inserted in a heat exchange tube and internally expanded into contact with the inside surface of the heat exchange tube for preventing flow of a coolant through the heat exchange tube. The tube plug also comprises a groove extending around the outside circumference thereof which has an elastomeric material disposed in the groove for enhancing the seal between the tube plug and the tube

  3. Prospective randomized trial compares suction versus water seal for air leaks.

    Science.gov (United States)

    Cerfolio, R J; Bass, C; Katholi, C R

    2001-05-01

    Surgeons treat air leaks differently. Our goal was to evaluate whether it is better to place chest tubes on suction or water seal for stopping air leaks after pulmonary surgery. A second goal was to evaluate a new classification system for air leaks that we developed. Patients were prospectively randomized before surgery to receive suction or water seal to their chest tubes on postoperative day (POD) #2. Air leaks were described and quantified daily by a classification system and a leak meter. The air-leak meter scored leaks from 1 (least) to 7 (greatest). The group randomized to water seal stayed on water seal unless a pneumothorax developed. On POD #2, 33 of 140 patients had an air leak. Eighteen patients had been preoperatively randomized to water seal and 15 to suction. Air leaks resolved in 12 (67%) of the water seal patients by the morning of POD #3. All 6 patients whose air leak did not stop had a leak that was 4/7 or greater (p leak meter. Of the 15 patients randomized to suction, only 1 patient's air leak (7%) resolved by the morning of POD #3. The randomization aspect of the trial was ended and statistical analysis showed water seal was superior (p = 0.001). The remaining 14 patients were then placed to water seal and by the morning of POD #4, 13 patients' leaks had stopped. Of the 32 total patients placed to seal, 7 (22%) developed a pneumothorax and 6 of these 7 patients had leaks that were 4/7 or greater (p = 0.001). Placing chest tubes on water seal seems superior to wall suction for stopping air leaks after pulmonary resection. However, water seal does not stop expiratory leaks that are 4/7 or greater. Pneumothorax may occur when chest tubes are placed on seal with leaks this large.

  4. Assembly and method for testing the integrity of stuffing tubes

    Energy Technology Data Exchange (ETDEWEB)

    Morrison, E.F.

    1996-12-31

    A stuffing tube integrity checking assembly includes first and second annular seals, with each seal adapted to be positioned about a stuffing tube penetration component. An annular inflation bladder is provided, the bladder having a slot extending longitudinally there along and including a separator for sealing the slot. A first valve is in fluid communication with the bladder for introducing pressurized fluid to the space defined by the bladder when mounted about the tube. First and second releasible clamps are provided. Each clamp assembly is positioned about the bladder for securing the bladder to one of the seals for thereby establishing a fluid-tight chamber about the tube.

  5. Intraoral Temperature Triggered Shape-Memory Effect and Sealing Capability of A Transpolyisoprene-Based Polymer

    Directory of Open Access Journals (Sweden)

    Gakuji Tsukada

    2015-11-01

    Full Text Available In dentistry, pure gutta-percha (trans-1,4-polyisoprene (TPI is widely used as a main component of root canal filling materials. TPI has an interesting shape memory formed through cross-linking, and this characteristic is expected to be very effective for development of novel dental treatments; in particular, modification of the shape recovery temperature to the intraoral temperature (37 °C will enhance the applicability of the shape-memory effect of TPI in root canal filling. In this study, trial test specimens consisting of varying proportions of TPI, cis-polyisoprene, zinc oxide, stearic acid, sulfur and dicumyl peroxide were prepared and the temperature dependence of their shape recovery, recovery stress and relaxation modulus were measured. Additionally, their sealing abilities were tested using glass tubing and a bovine incisor. As the ratio of cross-linking agent in the specimens increased, a decrease in recovery temperature and an increase in recovery stress and recovery speed were observed. In addition, the test specimen containing the highest concentration of cross-linking agent showed superior sealing ability under a thermal stimulus of 37 °C in both sealing ability tests.

  6. Square through tube

    International Nuclear Information System (INIS)

    Akita, Junji; Honma, Toei.

    1975-01-01

    Object: To provide a square through tube involving thermal movement in pipelines such as water supply pump driving turbine exhaust pipe (square-shaped), which is wide in freedom with respect to shape and dimension thereof for efficient installation at site. Structure: In a through tube to be airtightly retained for purpose of decontamination in an atomic power plant, comprising a seal rubber plate, a band and a bolt and a nut for securing said plate, the seal rubber plate being worked into the desired shape so that it may be placed in intimate contact with the concrete floor surface by utilization of elasticity of rubber, thereby providing airtightness at a corner portion of the square tube. (Kamimura, M.)

  7. Miniature fuel cells relieve gas pressure in sealed batteries

    Science.gov (United States)

    Frank, H. A.

    1971-01-01

    Miniature fuel cells within sealed silver zinc batteries consume evolved hydrogen and oxygen rapidly, preventing pressure rupturing. They do not significantly increase battery weight and they operate in all battery life phases. Complete gas pressure control requires two fuel cells during all phases of operation of silver zinc batteries.

  8. Efficiency calculations and optimization analysis of a solar reactor for the high temperature step of the zinc/zinc-oxide thermochemical redox cycle

    Energy Technology Data Exchange (ETDEWEB)

    Haussener, S.

    2007-03-15

    A solar reactor for the first step of the zinc/zinc-oxide thermochemical redox cycle is analysed and dimensioned in terms of maximization of efficiency and reaction conversion. Zinc-oxide particles carried in an inert carrier gas, in our case argon, enter the reactor in absorber tubes and are heated by concentrated solar radiation mainly due to radiative heat transfer. The particles dissociate and, in case of complete conversion, a gas mixture of argon, zinc and oxygen leaves the reactor. The aim of this study is to find an optimal design of the reactor regarding efficiency, materials and economics. The number of absorber tubes and their dimensions, the cavity dimension and its material as well as the operating conditions should be determined. Therefore 2D and 3D simulations of an 8 kW reactor are implemented. The gases are modeled as ideal gases with temperature-dependent properties. Absorption and scattering of the particle gas mixture are calculated by Mie-theory. Radiative heat transfer is included in the simulation and implemented with the aid of the discrete ordinates (DO) method. The mixture is modeled as ideal mixture and the reaction with an Arrhenius-type ansatz. Temperature distribution, reaction efficiency (heat used for zinc-oxide reaction divided by input) and tube efficiency (heat going into absorber tubes divided by input) as well as reaction conversion are analyzed to find the most promising reactor design. The results show that the most significant factors for efficiencies, conversion and absorber fluid temperature are concentration of the solar incoming radiation, zinc-oxide mass flow, the number of tubes and their dimension. Higher concentration leads to solely positive effects. Zinc-oxide mass flow variations indicate the existence of an optimal flow rate for each reactor design which maximizes efficiencies and conversion. Higher zinc-oxide mass flow leads, on one hand, to higher tube efficiency but on the other hand to lower temperatures in

  9. Development of a low-permeability glass--ceramic to seal to molybdenum

    International Nuclear Information System (INIS)

    Eagan, R.J.

    1975-03-01

    This report describes the development of low-permeability glass-ceramics which can be sealed directly to molybdenum for the purpose of producing long-life vacuum tubes. Low permeability to helium and thermal expansion match to molybdenum are the bases upon which particular glass-ceramic compositions were selected and developed. The fabrication of tube envelopes using glass-ceramics is simplified when compared to conventional ceramic/metal tubes and these melting and sealing techniques are presented

  10. Cannula has lip seal movingly coupled to proximal section, to facilitate relative movement of instrument shaft between seal and proximal section and to maintain sealing engagement between shaft and proximal portion

    OpenAIRE

    Bonadio, Frank; Vaugh, Trevor

    2007-01-01

    The cannula (1) has an instrument insertion section (3) and a tube (2) with an access channel (7) for extension of an instrument. A lip seal (4) movingly couples to a proximal section to engage with an instrument shaft (5). The seal facilitates a lateral movement of the instrument, and maintains the sealing engagement between the seal and the instrument shaft. A coupling portion made of gelatinous elastomeric material with plasticizer consisting of naturally derived oils, synthetic oils and l...

  11. Associated-particle sealed-tube neutron generators and hodoscopes for NDA applications

    International Nuclear Information System (INIS)

    Rhodes, E.; Peters, C.W.

    1991-01-01

    With radioisotope sources, gamma-ray transmission hodoscopes can inspect canisters and railcars to monitor rocket motors, can detect nuclear warheads by their characteristic strong gamma-ray absorption, or can count nuclear warheads inside a missile by low-resolution tomography. Intrinsic gamma-ray radiation from warheads can also be detected in a passive mode. Neutron hodoscopes can use neutron transmission, intrinsic neutron emission, or reactions stimulated by a neutron source, in treaty verification roles. Gamma-ray and neutron hodoscopes can be combined with a recently developed neutron diagnostic probe system, based on a unique associated-particle sealed-tube neutron generator (APSTNG) that interrogates the object of interest with a low-intensity beam of 14-MeV neutrons, and that uses flight-time to electronically collimate transmitted neutrons and to tomographically image nuclides identified by reaction gamma-rays. Gamma-ray spectra of resulting neutron reactions identify nuclides associated with all major chemicals in chemical warfare agents, explosives, and drugs, as well as many pollutants and fissile and fertile special nuclear material. 5 refs., 12 figs

  12. Method of start-up of rotary plug sealing devices in FBR type reactors

    International Nuclear Information System (INIS)

    Sakuragi, Masanori; Akita, Haruo

    1980-01-01

    Purpose: To rapidly and safely start-up the rotary plug sealing device by controlling to eliminate the pressure difference in the pressures of gases exerting on the liquid surfaces in the inner and the outer cylinders of a sealing alloy vessel in the rotary plug of a FBR type reactor. Method: In a case where an abnormal state results in the pressure difference of gases exerted on the liquid surfaces in the inner and the outer cylinders of a vessel charged with sealing alloy in a rotary plug and the sealing valve for the back-up gas supply tube is rapidly closed to seal the sealing portion, the pressure in the gas supply tube is controlled so that the pressure difference in the gases exerted on the liquid surfaces in the inner and outer cylinders while closing the sealing valve. Then, after conforming that the pressure is controlled to a predetermined level at which the pressure difference can be regarded to be zero, the sealing valve is gradually opened while regulating the pressure in the gas supply tube so as to maintain the pressure difference to a predetermined level. This prevents the occurrence of external disturbances upon opening of the sealing valve and enables rapid and safety start-up for the rotary plug sealing device. (Moriyama, K.)

  13. Advances in associated-particle sealed-tube neutron probe diagnostics for substance detection

    International Nuclear Information System (INIS)

    Rhodes, E.; Dickerman, C.E.; Frey, M.

    1995-01-01

    The development and investigation of a small associated-particle sealed-tube neutron generator (APSTNG) shows potential to allow the associated-particle diagnostic method to be moved out of the laboratory into field applications. The APSTNG interrogates the inspected object with 14-MeV neutrons generated from the deuterium-tritium reaction and detects the alpha-particle associated with each neutron inside a cone encompassing the region of interest. Gamma-ray spectra of resulting neutron reactions identify many nuclides. Flight-times determined from detection times of the gamma-rays and alpha-particles can yield a separate coarse tomographic image of each identified nuclide, from a single orientation. Chemical substances are identified by comparing relative spectral line intensities with ratios of elements in reference compounds. The high-energy neutrons and gamma-rays penetrate large objects and dense materials. Generally no collimators or radiation shielding are needed. Proof-of-concept laboratory experiments have been successfully performed for simulated nuclear, chemical warfare, and conventional munitions. Most recently, inspection applications have been investigated for radioactive waste characterization, presence of cocaine in propane tanks, and uranium and plutonium smuggling. Based on lessons learned with the present APSTNG system, an advanced APSTNG tube (along with improved high voltage supply and control units) is being designed and fabricated that will be transportable and rugged, yield a substantial neutron output increase, and provide sufficiently improved lifetime to allow operation at more than an order of magnitude increase in neutron flux

  14. Lifespan estimation of seal welded super stainless steels for water condenser of nuclear power plants

    Science.gov (United States)

    Kim, Young Sik; Park, Sujin; Chang, Hyun Young

    2014-01-01

    When sea water was used as cooling water for water condenser of nuclear power plants, commercial stainless steels can not be applied because chloride concentration exceeds 20,000 ppm. There are many opinions for the materials selection of tube and tube sheets of a condenser. This work reviewed the application guide line of stainless steels for sea-water facilities and the estimation equations of lifespan were proposed from the analyses of both field data for sea water condenser and experimental results of corrosion. Empirical equations for lifespan estimation were derived from the pit initiation time and re-tubing time of stainless steel tubing in sea water condenser of nuclear power plants. The lifespan of seal-welded super austenitic stainless steel tube/tube sheet was calculated from these equations. Critical pitting temperature of seal-welded PRE 50 grade super stainless steel was evaluated as 60 °C. Using the proposed equation in engineering aspect, tube pitting corrosion time of seal-welded tube/tube sheet was calculated as 69.8 years and re-tubing time was estimated as 82.0 years.

  15. Pediatric cuffed endotracheal tubes

    Directory of Open Access Journals (Sweden)

    Neerja Bhardwaj

    2013-01-01

    Full Text Available Endotracheal intubation in children is usually performed utilizing uncuffed endotracheal tubes for conduct of anesthesia as well as for prolonged ventilation in critical care units. However, uncuffed tubes may require multiple changes to avoid excessive air leak, with subsequent environmental pollution making the technique uneconomical. In addition, monitoring of ventilatory parameters, exhaled volumes, and end-expiratory gases may be unreliable. All these problems can be avoided by use of cuffed endotracheal tubes. Besides, cuffed endotracheal tubes may be of advantage in special situations like laparoscopic surgery and in surgical conditions at risk of aspiration. Magnetic resonance imaging (MRI scans in children have found the narrowest portion of larynx at rima glottides. Cuffed endotracheal tubes, therefore, will form a complete seal with low cuff pressure of <15 cm H 2 O without any increase in airway complications. Till recently, the use of cuffed endotracheal tubes was limited by variations in the tube design marketed by different manufacturers. The introduction of a new cuffed endotracheal tube in the market with improved tracheal sealing characteristics may encourage increased safe use of these tubes in clinical practice. A literature search using search words "cuffed endotracheal tube" and "children" from 1980 to January 2012 in PUBMED was conducted. Based on the search, the advantages and potential benefits of cuffed ETT are reviewed in this article.

  16. Seal for an object containing nuclear fuel

    International Nuclear Information System (INIS)

    Scheuerpflug, W.; Nentwich, D.

    1977-01-01

    This seal which cannot be counterfeited, specially for sealing nuclear objects, e.g. fuel rods, not only makes any damage which has taken place obvious, but makes identification according to a key possible. For this purpose a minimum number of 'particles' or small bodies, which are identical but of different permeability, are fixed inside a short tube during 'loading' of the seal in a certain or an accidental sequence. The sequence of the spheres, which represents a key, can only be determined by special electromagnetic measuring equipment. On first opening the seal, this key sequence is irrevocably destroyed. (HP) [de

  17. Development of a sealing process of capsules for surveillance test tubes of the vessel in nuclear power plants; Desarrollo de proceso de sellado de capsulas para probetas de vigilancia de la vasija en nucleoelectricas

    Energy Technology Data Exchange (ETDEWEB)

    Romero C, J.; Fernandez T, F.; Perez R, N.; Rocamontes A, M.; Garcia R, R. [ININ, Km 36.5 Carretera Mexico-Toluca, 52750 La Marquesa, Estado de Mexico (Mexico)

    2007-07-01

    The surveillance capsule is composed by the support, three capsules for impact test tubes, five capsules for tension test tubes and one porta dosemeters. The capsules for test tubes are of two types: rectangular capsule for Charpy test tubes and cylindrical capsule for tension test tubes. This work describes the development of the welding system to seal the capsules for test tubes that should contain helium of ultra high purity to a pressure of 1 atmosphere. (Author)

  18. Comparison of LMA-ProSealTM with LMA ClassicTM in Anaesthetised Paralysed Children

    Directory of Open Access Journals (Sweden)

    Pravesh Kanthed

    2008-01-01

    Full Text Available The classic laryngeal mask airway (cLMA, though popular in anaesthesia practice provides low oropharyngeal seal pressure and there are concerns with its use during positive pressure ventilation for fear of gastric distension with subsequent gastric regurgitation and pulmonary aspiration. The ProSeal laryngeal mask airway (PLMA is a modified LMA with a larger, wedge shaped cuff and a drain tube. This modification improves the seal around glottis when compared to a cLMA and its drain tube prevents gastric distension and offers protection against aspiration when properly placed. We compared PLMA and cLMA in 100 anaesthetized, paralysed children with 50 patients in each group with respect to ease of insertion, oropharyngeal seal pressure and pharyngolaryngeal morbidity. Gastric tube insertion was also assessed for the PLMA. The ease of insertion and the number of attempts at insertion were found to be comparable in the two groups while the oropharyngeal seal pressure was significantly higher in the PLMA group (P < 0.001. The pharyngolaryngeal morbidity was comparable in both the groups. There was no incidence of regurgitation or aspiration in either group. The PLMA offered high reliability of gastric tube placement and significantly increased oropharyngeal seal pressure over the cLMA. This might have an important implication for use of this device for positive pressure ventilation in children.

  19. Evaluation of RF seals for resonant cavity applications

    International Nuclear Information System (INIS)

    Rusnak, B.; Spalek, G.; Bolme, G.O.; Bultman, N.; Klapetkzy, A.; Kemp, E.L.; Stovall, J.E.; Rose, J.

    1991-01-01

    In radio-frequency quadrupoles (RFQ) and drift-tube linacs (DTL), electrical seals are required at mechanical interfaces to preserve the cavity quality factor (Q). Studies determined the response of copper-plated C-seals to continuous wave (cw), highfield operating conditions. In addition, low-power evaluations of machined-surface, knife-edge, indium wire, C-type, and multilam seals were done at room temperature and cryogenic (25 K) temperatures. For the high-field tests, the Q as well as seal temperature, was measured with power. For the low power test, the Q was measured as a function of temperature

  20. Confined Tube Crimp Using Portable Hand Tools

    Energy Technology Data Exchange (ETDEWEB)

    Reynolds, Joseph James [Los Alamos National Laboratory; Pereyra, R. A. [LANL Retired; Archuleta, Jeffrey Christopher [Los Alamos National Laboratory; Martinez, Isaac P. [Los Alamos National Laboratory; Nelson, A. M. [MST-16 Summer Student (2007); Allen, Ronald Scott [Los Alamos National Laboratory; Page, R. L. [LANL Retired; Freer, Jerry Eugene [Los Alamos National Laboratory; Dozhier, Nathan Gus [Los Alamos National Laboratory

    2016-04-04

    The Lawrence Radiation Laboratory developed handheld tools that crimp a 1/16 inch OD tube, forming a leak tight seal1 (see Figure 1). The leak tight seal forms by confining the 1/16 inch OD tubing inside a die while applying crimp pressure. Under confined pressure, the tube walls weld at the crimp. The purpose of this study was to determine conditions for fabricating a leak tight tube weld. The equipment was used on a trial-and-error basis, changing the conditions after each attempt until successful welds were fabricated. To better confine the tube, the die faces were polished. Polishing removed a few thousandths of an inch from the die face, resulting in a tighter grip on the tubing wall. Using detergent in an ultrasonic bath, the tubing was cleaned. Also, the time under crimp pressure was increased to 30 seconds. With these modifications, acceptable cold welds were fabricated. After setting the conditions for an acceptable cold weld, the tube was TIG welded across the crimped face.

  1. Management of chest tubes after pulmonary resection: a systematic review and meta-analysis.

    Science.gov (United States)

    Coughlin, Shaun M; Emmerton-Coughlin, Heather M A; Malthaner, Richard

    2012-08-01

    We performed a systematic review and meta-analysis to determine the effect of suction with water seal, compared with water seal alone, applied to intra pleural chest tubes on the duration of air leaks in patients undergoing pulmonary surgery. We searched MEDLINE, EMBASE and the Cochrane Central Register of Controlled Trials to find randomized controlled trials (RCTs) comparing the effect of the 2 methods on the duration of air leaks. Trials were systematically assessed for eligibility and validity. Data were extracted in duplicate and pooled across studies using a random-effects model. The search yielded 7 RCTs that met the eligibility criteria. No difference was identified between the 2 methods in duration of air leak (weighted mean difference [WMD] 1.15 days, favours water seal; 95% confidence interval [CI] -0.64 to 2.94), time to discharge (WMD 2.19 d, favours water seal; 95% CI -0.63 to 5.01), duration of chest tubes (WMD 0.96 d, favours water seal; 95% CI -0.12 to 2.05) or incidence of prolonged air leaks (absolute risk reduction [ARR] 0.04, favours water seal; 95% CI -0.01 to 0.09). Water seal was associated with a significantly increased incidence of postoperative pneumothorax (ARR -0.14, 95% CI -0.21 to -0.07). No differences were identified in terms of duration of air leak, incidence of prolonged air leak, duration of chest tubes and duration of hospital stay when chest tubes were placed to suction rather than water seal. Chest tube suction appears to be superior to water seal in reducing the incidence of pneumothorax; however, the clinical significance of this finding is unclear.

  2. High pressure mechanical seal

    Science.gov (United States)

    Babel, Henry W. (Inventor); Anderson, Raymond H. (Inventor)

    1996-01-01

    A relatively impervious mechanical seal is formed between the outer surface of a tube and the inside surface of a mechanical fitting of a high pressure fluid or hydraulic system by applying a very thin soft metal layer onto the outer surface of the hard metal tube and/or inner surface of the hard metal fitting. The thickness of such thin metal layer is independent of the size of the tube and/or fittings. Many metals and alloys of those metals exhibit the requisite softness, including silver, gold, tin, platinum, indium, rhodium and cadmium. Suitably, the coating is about 0.0025 millimeters (0.10 mils) in thickness. After compression, the tube and fitting combination exhibits very low leak rates on the order or 10.sup.-8 cubic centimeters per second or less as measured using the Helium leak test.

  3. An in vitro comparison of tracheostomy tube cuffs

    Directory of Open Access Journals (Sweden)

    Maguire S

    2015-04-01

    Full Text Available Seamus Maguire,1 Frances Haury,2 Korinne Jew2 1Research and Development, Covidien Respiratory and Monitoring Solutions, Athlone, Ireland; 2Medical Affairs, Covidien Respiratory and Monitoring Solutions, Boulder, CO, USA Introduction: The Shiley™ Flexible adult tracheostomy tube with TaperGuard™ cuff has been designed through its geometry, materials, diameter, and wall thickness to minimize micro-aspiration of fluids past the cuff and to provide an effective air seal in the trachea while also minimizing the risk of excessive contact pressure on the tracheal mucosa. The cuff also has a deflated profile that may allow for easier insertion through the stoma site. This unique design is known as the TaperGuard™ cuff. The purpose of the observational, in vitro study reported here was to compare the TaperGuard™ taper-shaped cuff to a conventional high-volume low-pressure cylindrical-shaped cuff (Shiley™ Disposable Inner Cannula Tracheostomy Tube [DCT] with respect to applied tracheal wall pressure, air and fluid sealing efficacy, and insertion force.Methods: Three sizes of tracheostomy tubes with the two cuff types were placed in appropriately sized tracheal models and lateral wall pressure was measured via pressure-sensing elements on the inner surface. Fluid sealing performance was assessed by inflating the cuffs within the tracheal models (25 cmH2O, instilling water above the cuff, and measuring fluid leakage past the cuff. To measure air leak, tubes were attached to a test lung and ventilator, and leak was calculated by subtracting the average exhaled tidal volume from the average delivered tidal volume. A tensile test machine was used to measure insertion force for each tube with the cuff deflated to simulate clinical insertion through a stoma site.Results: The average pressure exerted on the lateral wall of the model trachea was lower for the taper-shaped cuff than for the cylindrical cuff under all test conditions (P<0.05. The taper

  4. Process for obtaining oxygen doped zinc telluride monocrystals and scintillator crystals obtained by this process

    International Nuclear Information System (INIS)

    Schneider, Maurice; Moreau, Roland; D'Haenen, J.-P.; Merenda, Pierre.

    1976-01-01

    A process is described for obtaining oxygen doped zinc telluride monocrystals, for use as scintillator crystals for ionising radiation detectors. The following operations are carried out in succession: one or several zinc telluride crystals are introduced into a silica ampoule together with a ternary mixture of zinc tellurium and oxygen, as an oxide or hydroxide of these elements; the ampoule is pumped down to a high vacuum and sealed; the sealed ampoule containing the mixture and monocrystals is placed in a kiln and brought to a uniform temperature sufficient to make the mixture three-phased, depending on its composition; the zinc telluride crystalline compound remains solid; the ampoule is then tempered to bring it quickly back to ambient temperature [fr

  5. Design and development of face seal type sealing plug for advanced heavy water reactor

    International Nuclear Information System (INIS)

    Bansal, S.; Bhattacharyya, S.; Patel, R.J.; Agrawal, R.G.; Vaze, K.K.

    2005-09-01

    Advanced Heavy Water Reactor is a vertical pressure tube type reactor having light water as its coolant and heavy water as moderator. Sealing plug is required to close the pressure boundary of main heat transport system of the reactor by preventing escape of light water/steam From the coolant channel. There are 452 coolant channels in the reactor located in square lattice pitch. Sealing plug is located at the top of each coolant channel (in the top end fitting). Top end fitting is having a stepped bore to create a sealing face. Sealing plug is held through its expanded jaws in a specially provided groove of the end fitting. The plug was designed and prototypes were manufactured considering its functional importance, intricate design and precision machining requirements. Sealing plug consists of about 20 components mostly made up of precipitation hardening stainless steel, which is suitable for water environment and meets other requirements of strength and resistance to wear and galling. Seal disc is a critical component of the sealing plug as it is the pressure-retaining component. It is a circular disc with protruded stem. One face of the seal disc is nickel plated in the peripheral area that creates the sealing by abutting against the sealing face provided in the end fitting. The typical shape and profile of seal disc provides flexibility and allows elastic deformation to assist in locking of sealing plug and creating adequate seating force for effective sealing. Design and development aspects of the sealing plug have been detailed out in this report. Also results of stress analysis and experimental studies for seal disc have been mentioned in the report. Stress analysis and experimental testing was required for the seal disc because high stresses are developed due to its exposure to high pressure and temperature environment of Main Heat Transport system. Hot testing was carried out to simulate the reactor-simulated condition. The performance was found to be

  6. Management of chest drainage tubes after lung surgery.

    Science.gov (United States)

    Satoh, Yukitoshi

    2016-06-01

    Since chest tubes have been routinely used to drain the pleural space, particularly after lung surgery, the management of chest tubes is considered to be essential for the thoracic surgeon. The pleural drainage system requires effective drainage, suction, and water-sealing. Another key point of chest tube management is that a water seal is considered to be superior to suction for most air leaks. Nowadays, the most common pleural drainage device attached to the chest tube is the three-bottle system. An electronic chest drainage system has been developed that is effective in standardizing the postoperative management of chest tubes. More liberal use of digital drainage devices in the postoperative management of the pleural space is warranted. The removal of chest tubes is a common procedure occurring almost daily in hospitals throughout the world. Extraction of the tube is usually done at the end of full inspiration or at the end of full expiration. The tube removal technique is not as important as how it is done and the preparation for the procedure. The management of chest tubes must be based on careful observation, the patient's characteristics, and the operative procedures that had been performed.

  7. Design of analytical instrumentation with D-T sealed neutron generators

    International Nuclear Information System (INIS)

    Qiao Yahua; Wu Jizong; Zheng Weiming; Liu Quanwei; Zhang Min

    2008-01-01

    Analytical instrumentation with D-T sealed neutron generators source activation, The 14 MeV D-T sealed neutron tube with 10 9 n · s -1 neutron yield is used as generator source. The optimal structure of moderator and shield was achieved by MC computing.The instrumentation's configuration is showed. The instrumentation is made up of the SMY-DT50.8-2.1 sealed neutron tube and the high-voltage power supply system, which center is the sealed neutron generators. 6 cm Pb and 20 cm polythene is chosen as moderator, Pb, polythene and 10 cm boron-PE was chosen as shield .The sample box is far the source from 9 cm, the measurement system were made up of HPGe detector and the sample transforming system. After moderator and shield, the thermal neutron fluence rate at the point of sample is 0.93 × 10 6 n · s -1 cm -2 , which is accorded with design demand, and the laboratory and surroundings reaches the safety standard of the dose levels. (authors)

  8. {open_quotes}O{close_quotes} ring sealed process tube, Phase II, test project

    Energy Technology Data Exchange (ETDEWEB)

    Johnson, R.E.

    1951-04-09

    The {open_quotes}O{close_quotes} ring seal has been proposed to replace the van stone flange and the bellows thermal expansion assembly currently used on the existing Hanford piles to achieve water and gas seals, respectively. Possible advantages of the {open_quotes}O{close_quotes} ring seal are: (1) simplification of component parts and elimination of van stone corrosion; (2) simplification of maintenance; (3) lower costs of initial erection; (4) increased strength. This test supplements Test Project No. 27 (a preliminary thermal cycling test) in applying the {open_quotes}O{close_quotes} ring seal assembly to actual pile operating conditions.

  9. Use of a holder-vacuum tube device to save on-site hands in preparing urine samples for head-space gas-chromatography, and its application to determine the time allowance for sample sealing.

    Science.gov (United States)

    Kawai, Toshio; Sumino, Kimiaki; Ohashi, Fumiko; Ikeda, Masayuki

    2011-01-01

    To facilitate urine sample preparation prior to head-space gas-chromatographic (HS-GC) analysis. Urine samples containing one of the five solvents (acetone, methanol, methyl ethyl ketone, methyl isobutyl ketone and toluene) at the levels of biological exposure limits were aspirated into a vacuum tube via holder, a device commercially available for venous blood collection (the vacuum tube method). The urine sample, 5 ml, was quantitatively transferred to a 20-ml head-space vial prior to HS-GC analysis. The loaded tubes were stored at +4 ℃ in dark for up to 3 d. The vacuum tube method facilitated on-site procedures of urine sample preparation for HS-GC with no significant loss of solvents in the sample and no need of skilled hands, whereas on-site sample preparation time was significantly reduced. Furthermore, no loss of solvents was detected during the 3-d storage, irrespective of hydrophilic (acetone) or lipophilic solvent (toluene). In a pilot application, high performance of the vacuum tube method in sealing a sample in an air-tight space succeeded to confirm that no solvent will be lost when sealing is completed within 5 min after urine voiding, and that the allowance time is as long as 30 min in case of toluene in urine. The use of the holder-vacuum tube device not only saves hands for transfer of the sample to air-tight space, but facilitates sample storage prior to HS-GC analysis.

  10. Process and device for subdividing a glass tube filled with a radioactive gas

    International Nuclear Information System (INIS)

    Caffarella, T.E.; Radda, G.J.; Watts, D.J.

    1977-01-01

    A process is described for subdividing into individual sealed segments an elongated glass tube coated internally with a luminescent material and filled with a radioactive gas, this tube having a longitudinal axis. It consists in directing a focused laser beam on to the surface of the tube in an ambient atmosphere with a pressure greater than that of the gas in the tube and to create a relative, repetitive and alternating movement between the laser beam and the surface of the tube. This movement is transversal to the longitudinal axis of the tube, so as to heat and soften the tube along a cutting line until the tube divides and presents new ends where it contracts, causing these ends to seal up [fr

  11. Epoxy resins used to seal brachytherapy seed

    International Nuclear Information System (INIS)

    Ferreira, Natalia Carolina Camargos; Ferraz, Wilmar Barbosa; Reis, Sergio Carneiro dos; Santos, Ana Maria Matildes dos

    2013-01-01

    Prostate cancer treatment with brachytherapy is recommended for patients with cancer at an early stage. In this treatment, small radioactive seeds are implanted directly in the prostate gland. These seeds are composed at least of one radionuclide carrier and an X-ray marker enclosed within a metallic tube usually sealed by laser process. This process is expensive and, furthermore, it can provoke a partial volatilization of the radionuclide and change the isotropy in dose distribution around the seed. In this paper, we present a new sealing process using epoxy resin. Three kinds of resins were utilized and characterized by scanning electron microscopy (SEM), energy dispersive X ray (EDS) and by differential scanning calorimetry (DSC) after immersion in simulated body fluid (SBF) and in sodium iodine solution (NaI). The sealing process showed excellent potential to replace the sealing laser usually employed. (author)

  12. The Traumatic Tube: Bleeding Rectal Ulcer Caused by Flexi-Seal Device

    Directory of Open Access Journals (Sweden)

    Abhinav Tiwari

    2017-01-01

    Full Text Available Diarrhea and fecal incontinence are common in critically ill patients and present a challenging problem in patient management. The Flexi-Seal® Fecal Management System is a device to divert the stools away from the patient, thus improving the care to patients with fecal incontinence. There have been only few case reports describing the complications with the use of this device. Here, we present a case of a 77-year-old woman who was admitted due to massive hematochezia while on anticoagulation. She was found to have a large rectal ulcer caused by the Flexi-Seal device, used during the last hospital stay for fecal incontinence. Flexi-Seal device can be effective for the management of incontinence; however, caution should be exercised during handling and pressure from the retention balloon should be relieved periodically.

  13. Environmental contaminants in the food chain, NWS Seal Beach and Seal Beach NWR

    Energy Technology Data Exchange (ETDEWEB)

    Ohlendorf, H.M.; Byron, E.R. [CH2M Hill, Sacramento, CA (United States); Freas, K.E. [CH2M Hill, San Jose, CA (United States); Casados, E.M.; Kidwell, J.J. [Naval Facilities Engineering Command, San Diego, CA (United States). SW Division

    1994-12-31

    The authors conducted a study to determine whether environmental contaminants occurred in fish and invertebrates at concentrations that could be harmful to birds feeding in the estuarine salt marsh at Seal Beach National Wildlife Refuge (NWR), which is part of Naval Weapons Station (NWS) Seal Beach. Management of the refuge is focused primarily on endangered species, especially the light-footed clapper rail and the California least tern. Important food-chain organisms taken by rails (e.g., crabs and snails) and least terns (small fish) were sampled and analyzed for inorganic and organic contaminants that might be related to Navy activities at the Station. Results indicated that those contaminants are not likely to have lethal effects on rails or terns, although some chemicals (including cadmium, chromium, copper, lead, zinc and DDE) occurred at elevated concentrations in portions of the marsh. Possible sublethal effects also were evaluated and will be discussed.

  14. Gas sealing welding method and device for nuclear fuel rod

    International Nuclear Information System (INIS)

    Seki, Masayuki; Nishiyama, Motokuni; Kamimura, Katsuichiro; Yagi, Eiji; Nakase, Tsuyoshi; Kobogata, Sadao; Taniguchi, Jun-ichi; Uesugi, Yoshisaku.

    1995-01-01

    An end plug and a cladding tube are held by clamping, respectively, by opposing movable electrode and static electrode. The movable electrode is forwarded toward the static electrode. The end plug and the cladding tube are abutted and held at a slight gap between their end faces. A region to be welded is surrounded by a pressurizing chamber and the side of the chamber is evacuated and He gas is filled in the cladding tube. Then, one of the electrodes is forwarded, to seal the abutted end faces of the end plug and the cladding tube. Then, pressure and welding current required for welding are applied to the abutted ends, and He gas is sealed in the vessel. The displacement of pressurization caused by slipping when the required pressure is applied to the abutted ends is detected by a sensor, and the operation of the welding control device for starting current supply is terminated by the detection signals. Abutment accuracy between the abutment of the cladding tube and the end plug as a nuclear fuel rod can be ensured, to further improve and stabilize the welding quality. (N.H.)

  15. Recent development in PWR zinc injection

    International Nuclear Information System (INIS)

    Ocken, H.; Fruzzetti, K.; Frattini, P.; Wood, C.J.

    2002-01-01

    Zinc injection to the reactor coolant system (RCS) of PWRs holds the promise to alleviate two key challenges facing PWR plant operators: (1) reducing degradation of coolant system materials, including nickel-base alloy tubing and lower alloy penetrations due to stress corrosion cracking, and (2) lowering shutdown dose rates. Primary water stress corrosion cracking (PWSCC) is a dominant tube failure mode at many plants. This paper summarizes recent observations from U. S. and international PWRs that have implemented zinc injection, focusing primarily on coolant chemistry and dose rate issues. It also provides a look at the future direction of EPRI-sponsored projects on this topic. (authors)

  16. Determination of zinc concentration in female reproductive system by instrumental neutron activation

    International Nuclear Information System (INIS)

    Carvalho, Fernando Ramos de

    2009-01-01

    Non-surgical female sterilization through the transcervical insertion of quinacrine pellets was considered a definitive, low-cost, safe and effective contraceptive method. The zinc, present in both uterus and Fallopian tubes, inhibit the quinacrine efficiency. The addition of copper increases the efficacy of quinacrine, reducing the risk of pregnancy due to the failure to obstruct the Fallopian tubes. The copper neutralized the deleterious effect of the zinc and so the treatment efficacy is increased. In order to obtain a mapping to study the zinc content in the female reproductive system, samples of both uterus and Fallopian tubes were analyzed by instrumental neutron activation. The results show that, on average, the obtained zinc concentrations in tubes (89 μg-g -1 ) is lower than in the uterus (118 μg-g -1 ), confirming results obtained by other authors. These results will support a research project about non-surgical female sterilization of the 'Faculdade de Medicina da Universidade Federal de Minas Gerais' (Medical School of Federal University of Minas Gerais). The used methodology and obtained results are here reported. (author)

  17. Determination of zinc concentration in female reproductive system by instrumental neutron activation

    Energy Technology Data Exchange (ETDEWEB)

    Carvalho, Fernando Ramos de, E-mail: framosc@oi.com.b [Universidade Federal de Minas Gerais (UFMG), Belo Horizonte, MG (Brazil). Dept. de Engenharia Nuclear; Oliveira, Arno Heeren de, E-mail: heeren@nuclear.ufmg.b [Universidade Federal de Minas Gerais (UFMG), Belo Horizonte, MG (Brazil). Faculdade de Medicina. Dept. de Ginecologia e Obstetricia; Ferreira, Claudia R.C.; Ferreira, Ricardo Alberto Neto; Menezes, Maria Angela de B.C., E-mail: claudia@medicina.ufmg.b, E-mail: ranf@cdtn.b, E-mail: menezes@cdtn.b [Centro de Desenvolvimento da Tecnologia Nuclear (CDTN/CNEN-MG), Belo Horizonte, MG (Brazil)

    2009-07-01

    Non-surgical female sterilization through the transcervical insertion of quinacrine pellets was considered a definitive, low-cost, safe and effective contraceptive method. The zinc, present in both uterus and Fallopian tubes, inhibit the quinacrine efficiency. The addition of copper increases the efficacy of quinacrine, reducing the risk of pregnancy due to the failure to obstruct the Fallopian tubes. The copper neutralized the deleterious effect of the zinc and so the treatment efficacy is increased. In order to obtain a mapping to study the zinc content in the female reproductive system, samples of both uterus and Fallopian tubes were analyzed by instrumental neutron activation. The results show that, on average, the obtained zinc concentrations in tubes (89 mug-g{sup -1}) is lower than in the uterus (118 mug-g{sup -1}), confirming results obtained by other authors. These results will support a research project about non-surgical female sterilization of the 'Faculdade de Medicina da Universidade Federal de Minas Gerais' (Medical School of Federal University of Minas Gerais). The used methodology and obtained results are here reported. (author)

  18. Low-cost evacuated-tube solar collector appendices. Final report

    Energy Technology Data Exchange (ETDEWEB)

    Beecher, D.T.

    1980-05-31

    A low cost solar heat energy collector module and array has been designed using the evacuated tube, selective absorber, air cooled concept. Glass tubing as used in fluorescent lamps with automatic sealing methods is a key feature of the evacuated tube design. A molded fiber glass concentrating reflector panel and sheet metal header assembly are proposed. Major design problems involved included the cost of materials and labor, thermal expansion and distortion problems, high stagnation and operating temperatures, isolation, thermal efficiency, sealing, joining, air pressure drop, and weight of the preassembled module. A cost of less than $5 per active square foot of collecting surface has been estimated for materials and labor of the module and its mounting frame.

  19. Usefulness of normal saline for sealing the needle track after CT-guided lung biopsy

    International Nuclear Information System (INIS)

    Li, Y.; Du, Y.; Luo, T.Y.; Yang, H.F.; Yu, J.H.; Xu, X.X.; Zheng, H.J.; Li, B.

    2015-01-01

    Aim: To determine whether the use of normal saline for sealing the needle track can reduce the incidence of pneumothorax and chest tube placement after computed tomography (CT)-guided lung biopsy. Materials and methods: A prospective, randomised, controlled trial enrolling 322 patients was conducted. All patients were randomly assigned to one of two groups: those in whom the needle track was not sealed with normal saline (n=161, Group A) and those who did receive normal saline (n=161, Group B). CT-guided biopsy was performed with coaxial technique. Normal saline, which ranged from 1–3 ml, was injected while the trocar needle was being withdrawn. Patient characteristics, lesion, and procedure variables were analysed as potential risk variables for occurrence of pneumothorax and chest tube placement. Results: The incidence of pneumothorax was 26.1% in Group A and 6.2% in Group B (p<0.001). Nine patients in Group A and one patient in Group B required chest tube placement (p=0.010). Using multiple logistic regression analysis, smaller lesion size, greater needle–pleural angle, longer lesion–pleural distance, presence of emphysema, and no sealing the needle track with normal saline were significantly associated with an increased risk of pneumothorax, and that the latter three factors were also associated with an increased risk of pneumothorax requiring chest tube placement. Conlusion: Normal saline for sealing the needle track significantly reduces the incidence of pneumothorax and prevents subsequent chest tube placement after CT-guided lung biopsy. - Highlights: • Normal saline is an effective sealant for use in lung biopsy. • This technique reduced the incidence of pneumothorax and chest tube placement. • This technique should be recommended for CT-guided lung biopsy.

  20. Anti-corrosive Effects of Multi-Walled Carbon Nano Tube and Zinc Particle Shapes on Zinc Ethyl Silicate Coated Carbon Steel

    Energy Technology Data Exchange (ETDEWEB)

    Jang, JiMan; Shon, MinYoung; Kwak, SamTak [Pukyong National University, Busan (Korea, Republic of)

    2016-01-15

    Zinc ethyl silicate coatings containing multi walled carbon nanotubes (MWCNTs) were prepared, to which we added spherical and flake shaped zinc particles. The anti-corrosive effects of MWCNTs and zinc shapes on the zinc ethyl silicate coated carbon steel was examined, using electrochemical impedance spectroscopy and corrosion potential measurement. The results of EIS and corrosion potential measurement showed that the zinc ethyl silicate coated with flake shaped zinc particles and MWCNT showed lesser protection to corrosion. These outcomes were in agreement with previous results of corrosion potential and corrosion occurrence.

  1. Pillow seal system at the BigRIPS separator

    Energy Technology Data Exchange (ETDEWEB)

    Tanaka, K., E-mail: ktanaka@riken.jp; Inabe, N.; Yoshida, K.; Kusaka, K.; Kubo, T.

    2013-12-15

    Highlights: • Pillow seal system has been installed for a high-intensity RI-beam facility at RIKEN. • It is aimed at facilitating remote maintenance under high residual radiation. • Local radiation shields are integrated with one of the pillow seals. • Pillow seals have been aligned to the beam axis within 1mm accuracy. • A leakage rate of 10{sup –9} Pa m{sup 3}/s has been achieved with our pillow seal system. -- Abstract: We have designed and installed a pillow seal system for the BigRIPS fragment separator at the RIKEN Radioactive Isotope Beam Factory (RIBF) to facilitate remote maintenance in a radioactive environment. The pillow seal system is a device to connect a vacuum chamber and a beam tube. It allows quick attachment and detachment of vacuum connections in the BigRIPS separator and consists of a double diaphragm with a differential pumping system. The leakage rate achieved with this system is as low as 10{sup –9} Pa m{sup 3}/s. We have also designed and installed a local radiation-shielding system, integrated with the pillow seal system, to protect the superconducting magnets and to reduce the heat load on the cryogenic system. We present an overview of the pillow seal and the local shielding systems.

  2. Design, development and deployment of special sealing plug for 540 MWe PHWRs

    International Nuclear Information System (INIS)

    Sharma, G.; Roy, S.; Patel, R.J.

    2012-01-01

    The coolant channel in Pressurized Heavy Water Reactors is a pressure boundary component and is very important for reactor performance and reactor safety. Monitoring the condition of the pressure tube of each coolant channel on a periodic basis is very important. In-Service Inspection (ISI) of the coolant channels in water filled condition is done regularly for 220 MWe PHWR. For the same purpose BARC Channel Inspection System is developed for 540 MWe PHWR also. Special Sealing Plug has been developed to facilitate the channel inspection (in water filled condition) with all necessary safety features at par with normal sealing plug. Special Sealing Plug provides a 50 mm through hole for passage of drive tube of Inspection Head maintaining integrity of PHT. Lot of challenges were faced for developing the Special Sealing Plug and its associated tools. It was a first of its kind design. First ISI of TAPS-4 was conducted successfully using this plug along with associated tools in November 2011. This development has provided immense help to NPCIL in life management of 540 MWe PHWR coolant channels. (author)

  3. Floating seal system for rotary devices

    Science.gov (United States)

    Banasiuk, H.A.

    1983-08-23

    This invention relates to a floating seal system for rotary devices to reduce gas leakage around the rotary device in a duct and across the face of the rotary device to an adjacent duct. The peripheral seal bodies are made of resilient material having a generally U-shaped cross section wherein one of the legs is secured to a support member and the other of the legs forms a contacting seal against the rotary device. The legs of the peripheral seal form an extended angle of intersection of about 10[degree] to about 30[degree] in the unloaded condition to provide even sealing forces around the periphery of the rotary device. The peripheral seal extends around the periphery of the support member except where intersected by radial seals which reduce gas leakage across the face of the rotary device and between adjacent duct portions. The radial seal assembly is fabricated from channel bars, the smaller channel bar being secured to the divider of the support member and a larger inverted rigid floating channel bar having its legs freely movable over the legs of the smaller channel bar forming therewith a tubular channel. A resilient flexible tube is positioned within the tubular channel for substantially its full length to reduce gas leakage across the tubular channel. A spacer extends beyond the face of the floating channel near each end of the floating channel a distance to provide desired clearance between the floating channel and the face of the rotary device. 5 figs.

  4. Evaluation of a steam generator tube repair process using an explosive expansion techniuqe at TMI-1

    International Nuclear Information System (INIS)

    Rajan, J.; Shook, T.A.; Leonard, L.

    1983-01-01

    After a planned shutdown of Unit No. 1 at Three Mile Island, cracks were discovered in the primary side of steam generator tubes in the vicinity of the upper surface of the upper tubesheet. The nature of these cracks was later characterized as intergranular stress corrosion. The licensee, General Public Utilities Nuclear (GPUN), proposed to form a new tube-to-tubesheet seal below the cracks using a repair process wherein a detonating cord and polyethylene cartridge assembly inserted into the tube explosively expand the tube against the tubesheet. The explosive expansion process has had numerous applications over the years in the initial fabrication of heat exchanger tube-to-tubesheet assemblies and in repair processes using sleeving. However, this is the first use of this process in a steam generator to expand a previously rolled tube and to form a new seal between it and the tubesheet below a defective region in the tube. The seal obtained between the tube and tubesheet depends on the magnitude of explosive energy released in the detonating process. In this application, it is desired to obtain a mechanical bond rather than a metallurgical welding of the tube and tubesheet. A number of critical variables must be taken into account in order to obtain a successful mechanical seal. These include the explosive power of the detonating cord, the number of expansion shots used, the length of tube which is expanded, cartridge and tube diameters, the diameter of the tubesheet hole, the materials of the tube and tubesheet, and the condition of the surfaces at the time of repair. (orig./GL)

  5. Apparatus for sealing access holes to cavities within the earth with rock glass

    International Nuclear Information System (INIS)

    Holman, R.R.

    1979-01-01

    Apparatus is disclosed for establishing a solid, very low permeable rock glass plug to seal access holes through rock to underground storage vaults. The apparatus is designed to supply a filler material having a constituency substantially matching that of the rock formation surrounding the access port to the vault, through a central feeder tube under pressure to the vault. Means are provided for heating the filler material and surrounding rock formation at the point where the filler material exits the feeder tube, to a temperature sufficient to melt both the rock formation and the filler material. The remaining portion of the feeder tube is cooled to preserve the surrounding rock formaion spaced from the feeder orifice. The melt at the extremity of the feeder tube is forced through the orifice to a region below the tool by the force of the pressure feed. As the melt is forced below the tool, the tool is retracted until the access hole is completely sealed. A second embodiment is provided to seal enlarged openings which further includes a cooled core follower that enables the deposit to be fused in layers closing in the circumference of the hole until a final pass fuses the central core

  6. Electrochemical behavior of tube-fin assembly for an aluminum automotive condenser with improved corrosion resistance

    Science.gov (United States)

    Pech-Canul, M. A.; Guía-Tello, J. C.; Pech-Canul, M. I.; Aguilar, J. C.; Gorocica-Díaz, J. A.; Arana-Guillén, R.; Puch-Bleis, J.

    An aluminum automotive condenser was designed to exhibit high corrosion resistance in the seawater acetic acid test (SWAAT) combining zinc coated microchannel tubes and fins made with AA4343/AA3003(Zn)/AA4343 brazing sheet. Electrochemical measurements in SWAAT solution were carried out under laboratory conditions using tube-fin assembly and individual fin and tube samples withdrawn from the condenser core. The aim was to gain information on the protective role of the zinc sacrificial layer and about changes in corrosion behavior as a function of immersion time. External corrosion of the tube-fin system was simulated by immersion of mini-core samples under open circuit conditions. The corrosion rate increased rapidly during the first 6 h and slowly afterwards. The short time behavior was related to the dissolution of the oxide film and fast dissolution of the outermost part of the zinc diffusion layer. With the aid of cross-sectional depth corrosion potential profiles, it was shown that as the sacrificial layer gets dissolved, the surface concentration of zinc decreases and the potential shifts to less negative values. The results of galvanic coupling of tube and fins in a mini-cell showed that the tube became the anode while the fins exhibited cathodic behavior. An evolution in the galvanic interaction was observed, due to the progressive dissolution of the sacrificial zinc layer. The difference of uncoupled potentials between tube and fins decreased from 71 mV to 32 mV after 84 h of galvanic coupling. At the end of such period there was still a part of the zinc sacrificial layer remaining which would serve for protection of the tube material for even longer periods and there were indications of slight corrosion in the fins.

  7. Electrochemical behavior of tube-fin assembly for an aluminum automotive condenser with improved corrosion resistance

    Directory of Open Access Journals (Sweden)

    M.A. Pech-Canul

    Full Text Available An aluminum automotive condenser was designed to exhibit high corrosion resistance in the seawater acetic acid test (SWAAT combining zinc coated microchannel tubes and fins made with AA4343/AA3003(Zn/AA4343 brazing sheet. Electrochemical measurements in SWAAT solution were carried out under laboratory conditions using tube-fin assembly and individual fin and tube samples withdrawn from the condenser core. The aim was to gain information on the protective role of the zinc sacrificial layer and about changes in corrosion behavior as a function of immersion time. External corrosion of the tube-fin system was simulated by immersion of mini-core samples under open circuit conditions. The corrosion rate increased rapidly during the first 6 h and slowly afterwards. The short time behavior was related to the dissolution of the oxide film and fast dissolution of the outermost part of the zinc diffusion layer. With the aid of cross-sectional depth corrosion potential profiles, it was shown that as the sacrificial layer gets dissolved, the surface concentration of zinc decreases and the potential shifts to less negative values. The results of galvanic coupling of tube and fins in a mini-cell showed that the tube became the anode while the fins exhibited cathodic behavior. An evolution in the galvanic interaction was observed, due to the progressive dissolution of the sacrificial zinc layer. The difference of uncoupled potentials between tube and fins decreased from 71 mV to 32 mV after 84 h of galvanic coupling. At the end of such period there was still a part of the zinc sacrificial layer remaining which would serve for protection of the tube material for even longer periods and there were indications of slight corrosion in the fins. Keywords: Aluminum, Automotive, Corrosion, Galvanic, Zn coating

  8. Seals and sealing handbook

    CERN Document Server

    Flitney, Robert K

    2014-01-01

    Seals and Sealing Handbook, 6th Edition provides comprehensive coverage of sealing technology, bringing together information on all aspects of this area to enable you to make the right sealing choice. This includes detailed coverage on the seals applicable to static, rotary and reciprocating applications, the best materials to use in your sealing systems, and the legislature and regulations that may impact your sealing choices. Updated in line with current trends this updated reference provides the theory necessary for you to select the most appropriate seals for the job and with its 'Failur

  9. Sealing wells with gel

    Energy Technology Data Exchange (ETDEWEB)

    Lopez, E C

    1967-10-01

    A new system is being used in Mexico to temporarily plug producing wells. The temporary seal is a gel with a catalyst. The use of this temporary plug allows gas-lift wells to be taken off production in order to carry out emergency repairs. The gel solidifies by the action of the catalyst to a high temperature (70 - 150/sup 0/C). By locating the bottom of the tubing at the top of the production interval, the gel material will go into the permeable formation, and immediately set. When the gel has solidified, it seals off the horizon that must not be stimulated, and leaves the others exposed to the acid action. When the treatment is finished, the gel, by action of the catalyst, is liquefied and removed from the formation, being produced with the oil.

  10. The use of a water seal to manage air leaks after a pulmonary lobectomy: a retrospective study.

    Science.gov (United States)

    Okamoto, Junichi; Okamoto, Tatsuro; Fukuyama, Yasuro; Ushijima, Chie; Yamaguchi, Masafumi; Ichinose, Yukito

    2006-08-01

    The methods for managing chest drainage tubes during the postoperative period differ among thoracic surgeons and, as a result, the optimal method remains controversial. We reviewed 170 consecutive patients undergoing a pulmonary lobectomy for either primary lung cancer or metastatic lung cancer from January 1998 to December 2002. After the operation, the chest drainage tube was placed on a suction pump with a negative pressure of -10 cmH(2)O in 120 patients before 2001, while such drainage tubes were kept on water seal in 47 cases mainly since 2001. Regarding the preoperative and postoperative variables, postoperative air leak as well as the video-assisted thoracic surgery (VATS) procedure were more frequently observed in the water seal group than in the suction group (p=0.01580, pleak seemed to be similar between the two methods. These observations suggest that applying chest tubes on water seal seems to be an effective method for preventing postoperative air leak in clinical practice. However, a prospective randomized trial using a larger series of patients is warranted for this subject.

  11. Sealed drift tube cosmic ray veto counters

    International Nuclear Information System (INIS)

    Rios, R.; Tatar, E.; Bacon, J.D.; Bowles, T.J.; Hill, R.; Green, J.A.; Hogan, G.E.; Ito, T.M.; Makela, M.; Morris, C.L.; Mortenson, R.; Pasukanics, F.E.; Ramsey, J.; Saunders, A.; Seestrom, S.J.; Sondheim, W.E.; Teasdale, W.; Saltus, M.; Back, H.O.; Cottrell, C.R.

    2011-01-01

    We describe a simple drift tube counter that has been used as a cosmic ray veto for the UCNA experiment, a first-ever measurement of the neutron beta-asymmetry using ultra-cold neutrons. These detectors provide an inexpensive alternative to more conventional scintillation detectors for large area cosmic ray anticoincidence detectors.

  12. Sealing ability of hydroxyapatite as a root canal sealer: in vitro study

    Directory of Open Access Journals (Sweden)

    Widowati Witjaksono

    2007-09-01

    Full Text Available Hydroxyapatite (HA is the most thermodynamically synthetic calcium phosphate cement, and has indicated useful as a sealer because can seal a furcation perforation, is shown to be biocompatible and also has potential to promote the healing of bone in endodontic therapy. The objective of this study is to determine the sealing ability of HA produced by School of Engineering, Universiti Sains Malaysia (USM when used as a sealer in root canal obturation, compare with Tubli-seal (Zinc-Oxide base and Sealapax (Calcium Hydroxyde base sealers. Forty five single rooted human anterior teeth were instrumented and randomly divided into three experimental groups of 15 teeth each. All teeth in the experimental groups were obturated with laterally condensed gutta percha technique. Teeth in the first group were sealed using Zinc-Oxide (ZnO based sealer and those of second group using Calcium Hydroxide (CaOH based root canal sealer. Third experimental group was sealed using HA from School of Engineering USM. Teeth were then suspended in 2% methylene blue. After this, teeth were demineralized dehydrated and cleared. Linear dye penetration was determined under magnifying lense with calibrated eye piece. Statistical analyses of the linear dye penetration were performed with Kruskal Wallis test. The intergroup comparison between HA and ZnO groups and CaOH groups were analyzed by Mann-Whitney test. The dye penetration for group which were sealed with HA exhibited the lowest penetration and it showed that there was a statistically significant difference both between HA and ZnO groups and also between HA and CaOH groups (p < 0.001.In conclusion, it was found that value added HA based endodontic material which were produced by USM can be used as a root canal sealing materials when it used in combination with epoxy resin since it leaked comparatively less as compared to ZnO and CaOH sealers. Before reaching a definitive conclusion, this material requires further extensive

  13. Managing a chest tube and drainage system.

    Science.gov (United States)

    Durai, Rajaraman; Hoque, Happy; Davies, Tony W

    2010-02-01

    Intercostal drainage tubes (ie, chest tubes) are inserted to drain the pleural cavity of air, blood, pus, or lymph. The water-seal container connected to the chest tube allows one-way movement of air and liquid from the pleural cavity. The container should not be changed unless it is full, and the chest tube should not be clamped unnecessarily. After a chest tube is inserted, a nurse trained in chest-tube management is responsible for managing the chest tube and drainage system. This entails monitoring the chest-tube position, controlling fluid evacuation, identifying when to change or empty the containers, and caring for the tube and drainage system during patient transport. This article provides an overview of indications, insertion techniques, and management of chest tubes. Copyright 2010 AORN, Inc. Published by Elsevier Inc. All rights reserved.

  14. Use of Microcuff ® endotracheal tubes in paediatric laparoscopic surgeries

    Directory of Open Access Journals (Sweden)

    Rameshwar Mhamane

    2015-01-01

    Full Text Available Background and Aims: Traditionally, uncuffed endotracheal tubes have been used in children. Cuffed tubes may be useful in special situations like laparoscopy. Microcuff ® endotracheal tube is a specifically designed cuffed endotracheal tube for the paediatric airway. We studied the appropriateness of Microcuff ® tube size selection, efficacy of ventilation, and complications, in children undergoing laparoscopy. Methods: In a prospective, observational study, 100 children undergoing elective laparoscopy were intubated with Microcuff ® tube as per recommended size. We studied appropriateness of size selection, sealing pressure, ability to ventilate with low flow, quality of capnography and post-extubation laryngospasm or stridor. Results: Mean age of the patients was 5.44 years (range 8 months 5 days-9 years 11 months. There was no resistance for tube passage during intubation in any patient. Leak on intermittent positive pressure ventilation at airway pressure ≤20 cm H 2 O was present in all patients. Mean sealing pressure was 11.72 (1.9 standard deviation [SD] cm H 2 O. With the creation of pnemoperitoneum, mean intracuff pressure increased to 12.48 (3.12 SD cm H 2 O. With head low positioning, mean cuff pressure recorded was 13.32 (2.92 SD. Ventilation at low flow (mean flow 1 L/min, plateau-type capnography was noted in all patients. Mean duration of intubation was 83.50 min. Coughing at extubation occurred in 6 patients. Partial laryngospasm occurred in 4 patients, which responded to continuous positive airway pressure via face mask. Severe laryngospasm or stridor was not seen in any patient. Conclusion: Microcuff ® tubes can be safely used in children if size selection recommendations are followed and cuff pressure is strictly monitored. Advantages are better airway seal and effective ventilation, permitting use of low flows.

  15. The use of geotextile tube containers for dewatering the Restigouche open pit zinc mine and settling pond basin in New Brunswick, Canada

    Energy Technology Data Exchange (ETDEWEB)

    Douheret [Terratube, Saint-Romuald, PQ (Canada)

    2010-07-01

    This PowerPoint presentation discussed the use of geotextile tube containers for the dewatering of an open pit zinc mine and settling pond in New Brunswick (NB). The zinc and lead mine closed in 1996 and will be re-opened in 2007. Remediation of the site has been challenged by severe discharge criteria for treated water, as well as by the different types of wastewater produced at the site, which is located in a mountainous area with no impermeable soil. The remediation projects include an open pit cleaning procedure where water is removed and the mine is then desludged. A wastewater treatment plant will then be installed. More than 32,000 m{sup 3} of sludge has accumulated at the bottom of the pit. The zinc content of the sludge was estimated at 2.5 ppm. The water management phase of the project will include batch treatments and the addition of 140 metric tonnes of lime to raise the pH and to precipitate metal ions. The sludge management program included the use of mechanical dewatering, the construction of a storage area, and the use of geocontainers for dewatering and temporary containment. Seventeen geotextile containers were used to reduce the zinc content of the water to less than the 250 ppb authorized by environmental agencies. The containers were changed once every 2 months. tabs., figs.

  16. 46 CFR 171.100 - Shaft tunnels and stern tubes.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 7 2010-10-01 2010-10-01 false Shaft tunnels and stern tubes. 171.100 Section 171.100... PERTAINING TO VESSELS CARRYING PASSENGERS Additional Subdivision Requirements § 171.100 Shaft tunnels and... passengers on an international voyage. (b) The watertight seal in the bulkhead between the stern tube space...

  17. New tube fitting range can slash assembly time, reduce tube material costs and eliminate hot work

    Energy Technology Data Exchange (ETDEWEB)

    Anon.

    2008-09-15

    Parker Instrumentation has developed a permanent tube connection technology known as Phastite for use in high pressure applications such as in the offshore oil and gas sector. The Phastite push-fit connector offers major savings over traditional permanent and higher pressure connection techniques such as welded or cone-and-thread tube fittings. It also reduces assembly times by 20-fold or more and eliminates the need for hot work permits. The fittings are designed to withstand working pressures up to 1,379 bar. Phastite tube fittings can be used on offshore platforms, as well as on support vessels,, subsea equipment and ROVs such as hydraulic systems for wellhead control, emergency shut down, chemical injection, pumping packages, gas booster systems and test equipment. The connectors offer considerable savings in material cost and weight because they do not need to be used with more expensive tubing with extra thickness to accommodate a thread. Phastite is also resistant to vibration and does not need any anti-vibration accessories. A joint can be made in a matter of seconds with a simple handheld hydraulic tool that makes the push-fit connection. A sealing mechanism based on a series of defined internal ridges creates a secure seal by radial compression. The ridges grip in a way that retains all of the tubing's strength. An additional characteristic is the maintenance free nature of the Phastite connection. 1 fig.

  18. Novel Seals and Specialty Component Attachment Mechanisms for Respiratory Protection System (RESPO 21)

    Science.gov (United States)

    1992-10-01

    use in a warm clima ,, Ao~ hccts rovcf rur % Cr. ugc na il oimnte nber o prna in ntting materil coupled to skin separat lc~oe tect wocn f h~i. Sae...the mask shell on the side vagina and cervix of a woman in labor , electrode meam &h thereof facing the face. said sealing tube having a fixed sealed

  19. Novel texturing method for sputtered zinc oxide films prepared at high deposition rate from ceramic tube targets

    Directory of Open Access Journals (Sweden)

    Hüpkes J.

    2011-10-01

    Full Text Available Sputtered and wet-chemically texture etched zinc oxide (ZnO films on glass substrates are regularly applied as transparent front contact in silicon based thin film solar cells. In this study, chemical wet etching in diluted hydrofluoric acid (HF and subsequently in diluted hydrochloric acid (HCl on aluminum doped zinc oxide (ZnO:Al films deposited by magnetron sputtering from ceramic tube targets at high discharge power (~10 kW/m target length is investigated. Films with thickness of around 800 nm were etched in diluted HCl acid and HF acid to achieve rough surface textures. It is found that the etching of the films in both etchants leads to different surface textures. A two steps etching process, which is especially favorable for films prepared at high deposition rate, was systematically studied. By etching first in diluted hydrofluoric acid (HF and subsequently in diluted hydrochloric acid (HCl these films are furnished with a surface texture which is characterized by craters with typical diameter of around 500 − 1000 nm. The resulting surface structure is comparable to etched films sputtered at low deposition rate, which had been demonstrated to be able to achieve high efficiencies in silicon thin film solar cells.

  20. Revisiting resolution in hydrodynamic countercurrent chromatography: tubing bore effect.

    Science.gov (United States)

    Berthod, A; Faure, K

    2015-04-17

    A major challenge in countercurrent chromatography (CCC), the technique that works with a support-free biphasic liquid system, is to retain the liquid stationary phase inside the CCC column (Sf parameter). Two solutions are commercially available: the hydrostatic CCC columns, also called centrifugal partition chromatographs (CPC), with disks of interconnected channels and rotary seals, and the hydrodynamic CCC columns with bobbins of coiled open tube and no rotary seals. It was demonstrated that the amount of liquid stationary phase retained by a coiled tube was higher with larger bore tubing than with small bore tubes. At constant column volume, small bore tubing will be longer producing more efficiency than larger bore tube that will better retain the liquid stationary phase. Since the resolution equation in CCC is depending on both column efficiency and stationary phase retention ratio, the influence of the tubing bore should be studied. This theoretical work showed that there is an optimum tubing bore size depending on solute partition coefficient and mobile phase flow rate. The interesting result of the theoretical study is that larger tubing bores allow for dramatically reduced experiment durations for all solutes: in reversed phase CCC (polar mobile phase), hydrophobic solutes are usually highly retained. These apolar solutes can be separated by the same coil at high flow rates and reduced Sf with similar retention times as polar solutes separated at smaller flow rates and much higher Sf. Copyright © 2015 Elsevier B.V. All rights reserved.

  1. A shut-off valve for flexible tubing

    Science.gov (United States)

    Reyburn, W. W.

    1972-01-01

    Design of light weight valve for flexible tubing is described. Valve is hand operated and provides positive sealing in normally closed position. Diagram is provided to show construction of valve. Principles of operation are explained.

  2. Research, development, and demonstration of nickel-zinc batteries for electric vehicle propulsion. Annual report for 1980

    Energy Technology Data Exchange (ETDEWEB)

    1981-03-01

    Progress in the development of nickel-zinc batteries for electric vehicles is reported. Information is presented on nickel electrode preparation and testing; zinc electrode preparation with additives and test results; separator development and the evaluation of polymer-blend separator films; sealed Ni-Zn cells; and the optimization of electric vehicle-type Ni-Zn cells. (LCL)

  3. Novel silver tubing method for quantitative introduction of water into high temperature conversion systems for stable hydrogen and oxygen isotopic measurements

    Science.gov (United States)

    Qi, Haiping; Groning, Manfred; Coplen, Tyler B.; Buck, Bryan; Mroczkowski, Stanley J.; Brand, Willi A.; Geilmann, Heike; Gehre, Matthias

    2010-01-01

    A new method to seal water in silver tubes for use in a TC/EA reduction unit using a semi-automated sealing apparatus can yield reproducibilities (1 standard deviation) of δ2H and &delta18O measurements of 1.0 ‰ and 0.06 ‰, respectively. These silver tubes containing reference waters may be preferred for calibration of H- and O-bearing materials analyzed with a TC/EA reduction unit. The new sealing apparatus employs a computer controlled stepping motor to produce silver tubes identical in length. The reproducibility of mass of water sealed in tubes (in a range of 200 to 400 µg) can be as good as 1 percent. Although silver tubes sealed with reference waters are robust and can be shaken or heated to 110 °C with no loss of integrity, they should not be frozen because the expansion during the phase transition of water to ice will break the cold seals and all water will be lost. They should be shipped in insulated containers. This new method eliminates air inclusions and isotopic fractionation of water associated with the loading of water into capsules using a syringe. The method is also more than an order of magnitude faster than preparing water samples in ordinary Ag capsules. Nevertheless, some laboratories may prefer loading water into silver capsules because expensive equipment is not needed, but they are cautioned to apply the necessary corrections for evaporation, back exchange with laboratory atmospheric moisture, and blank.

  4. Comparison of ProSeal laryngeal mask airway (PLMA with cuffed and uncuffed endotracheal tubes in infants

    Directory of Open Access Journals (Sweden)

    Eyyup Sabri Ozden

    2016-11-01

    Full Text Available We aimed to compare cuffed and uncuffed endotracheal tubes (ETTs with ProSealTM laryngeal mask airway (PLMA in terms of airway security and extubation, starting out from the hypothesis that PLMA will provide alternative airway safety to the endotracheal tubes, and that airway complications will be less observed. After obtaining approval from the local Ethics Committee and parental informed consent, 120 pediatric patients 1-24 months old, American Society of Anesthesiologists physical status I-II, requiring general anesthesia for elective lower abdominal surgery, were randomized into PLMA (Group P, n = 40, cuffed ETT (Group C, n = 40, and uncuffed ETT (Group UC, n = 40 groups. The number of intubation or PLMA insertion attempts was recorded. Each patient’s epigastrium was auscultated for gastric insufflation, leak volumes and air leak fractions (leak volume/inspiratory volume were recorded. Post-operative adverse events related to airway management were also followed up during the first post-operative hour. Demographic and surgical data were similar among the groups. There were significantly fewer airway manipulations in the Group P than in the other groups (p < 0.01, and leak volume and air leak fractions were greater in the Group UC than in the other two groups (p < 0.01. Laryngospasm was significantly lower in the Group P during extubation and within the first minute of post-extubation than in the other groups (p < 0.01. Based on this study, PLMA may be a good alternative to cuffed and uncuffed ETTs for airway management of infants due to the ease of manipulation and lower incidence of laryngospasm.

  5. Tritium application: self-luminous glass tube(SLGT)

    International Nuclear Information System (INIS)

    Kim, K.; Lee, S.K.; Chung, E.S.; Kim, K.S.; Kim, W.S.; Nam, G.J.

    2005-01-01

    To manufacture SLGTs (self-luminous glass tubes), 4 core technologies are needed: coating technology, tritium injection technology, laser sealing/cutting technology and tritium handling technology. The inside of the glass tubes is coated with greenish ZnS phosphor particles with sizes varying from 4∝5 [μm], and Cu, and Al as an activator and a co-dopant, respectively. We also found that it would be possible to produce a phosphor coated glass tube for the SLGT using the well established cold cathode fluorescent lamp (CCFL) bulb manufacturing technology. The conceptual design of the main process loop (PL) is almost done. A delicate technique will be needed for the sealing/cutting of the glass tubes. Instead of the existing torch technology, a new technology using a pulse-type laser is under investigation. The design basis of the tritium handling facilities is to minimize the operator's exposure to tritium uptake and the emission of tritium to the environment. To fulfill the requirements, major tritium handling components are located in the secondary containment such as the glove boxes (GBs) and/or the fume hoods. The tritium recovery system (TRS) is connected to a GB and PL to minimize the release of tritium as well as to remove the moisture and oxygen in the GB. (orig.)

  6. Application tests of a remote controlled machine for laser sealing and cutting of pipelines in hazardous circuits

    Energy Technology Data Exchange (ETDEWEB)

    Cai, G. (Ansaldo SpA, Genoa (Italy)); Cantello, M.; Accampo, G.

    1991-12-01

    This short communication deals with the experimental investigation on sealing and cutting tubes with the same laser beam after partial compression of the tube using presses of limited force easy to install on a robot for dismantling chemical or nuclear plants.

  7. A method and machine for forming pleated and bellow tubes

    International Nuclear Information System (INIS)

    Banks, J.W.

    1975-01-01

    In a machine, the rollers outside the rough tube are rigidly supported for assuring the accurate forming of each turn of the pleated tube, the latter being position-indexed independently of the already formed turns. An inner roller is supported by a device for adjusting and indexing the position thereof on a carriage. The thus obtained tubes are suitable, in particular, for forming expansion sealing joints for power generators or nuclear reactors [fr

  8. Inflatable bag with sealing and protection layer

    International Nuclear Information System (INIS)

    Kocourek, L.; Dohnal, M.; Klinga, J.; Matal, O.; Holy, F.

    1989-01-01

    The inflatable bag consists of a textile casing in which a cylindrical pvc tyre with concave bottoms is inserted and glued to the casing. A sealing protective layer is provided on the outer periphery of the cylindrical part of the tyre. A tyre valve with flange and fixing ears and also a relief valve are provided in the concave bottom. The casing material, such as a layer of 0.5 to 5 mm silicone rubber bands is suitable for use in contact with austenitic materials. The bag completely seals spaces such as the mouths of steam generator tubes or collector branches in a nuclear power plant. Decontamination can easily be achieved by rinsing the surface with common means. (J.B.). 2 figs

  9. Tritium application: self-luminous glass tube(SLGT)

    Energy Technology Data Exchange (ETDEWEB)

    Kim, K.; Lee, S.K.; Chung, E.S.; Kim, K.S.; Kim, W.S. [Nuclear Power Lab., Korea Electric Power Research Inst. (KEPRI), Daejeon (Korea); Nam, G.J. [Engineering Information Technology Center, Inst. for Advanced Engineering (IAE), Kyonggi-do (Korea)

    2005-07-01

    To manufacture SLGTs (self-luminous glass tubes), 4 core technologies are needed: coating technology, tritium injection technology, laser sealing/cutting technology and tritium handling technology. The inside of the glass tubes is coated with greenish ZnS phosphor particles with sizes varying from 4{proportional_to}5 [{mu}m], and Cu, and Al as an activator and a co-dopant, respectively. We also found that it would be possible to produce a phosphor coated glass tube for the SLGT using the well established cold cathode fluorescent lamp (CCFL) bulb manufacturing technology. The conceptual design of the main process loop (PL) is almost done. A delicate technique will be needed for the sealing/cutting of the glass tubes. Instead of the existing torch technology, a new technology using a pulse-type laser is under investigation. The design basis of the tritium handling facilities is to minimize the operator's exposure to tritium uptake and the emission of tritium to the environment. To fulfill the requirements, major tritium handling components are located in the secondary containment such as the glove boxes (GBs) and/or the fume hoods. The tritium recovery system (TRS) is connected to a GB and PL to minimize the release of tritium as well as to remove the moisture and oxygen in the GB. (orig.)

  10. Open Zinc Freezing-Point Cell Assembly and Evaluation

    Science.gov (United States)

    Žužek, V.; Batagelj, V.; Drnovšek, J.; Bojkovski, J.

    2014-07-01

    An open metal freezing-point cell design has been developed in the Laboratory of Metrology and Quality. According to our design, a zinc cell was successfully assembled. The paper presents the needed parts for the cell, the cleaning process, and sealing of the cell. The assembled cell was then evaluated by comparison with two commercial closed zinc cells of different manufacturers. The freezing plateaus of the cells were measured, and a direct cell comparison was made. It was shown that the assembled open cell performed better than the used closed cell and was close to the brand new closed cell. The nominal purity of the zinc used for the open cell was 7 N, but the freezing plateau measurement suggests a higher impurity concentration. It was assumed that the zinc was contaminated to some extent during the process of cutting as its original shape was an irregular cylinder. The uncertainty due to impurities for the assembled cell is estimated to be 0.3 mK. Furthermore, the immersion profile and the pressure coefficient were measured. Both results are close to their theoretical values.

  11. Zinc dosing and glucose tolerance in humans

    International Nuclear Information System (INIS)

    Greenley, S.; Taylor, M.

    1986-01-01

    Animal data suggest the existence of a physiologic relationship between glucoregulatory hormones and zinc metabolism. In order to investigate this proposed relationship in humans, they examined the effect of moderately elevated plasma zinc levels on blood glucose clearance. Eight women (24-37 yrs) served as subjects for the study. Fasted volunteers were tested under two experimental conditions (a) ingestion of 50 g D-glucose (b) ingestion of 25 mg zinc followed 60 min later by ingestion of 50 g D-glucose. Five ml venous blood was drawn into trace-metal-free, fluoride-containing vacutainer tubes prior to and 15, 30, 45, 60, 90, and 120 min after glucose ingestion. Plasma was analyzed for glucose and zinc; glycemic responses were quantified by computing areas under the curves and times to peak concentration. Their human data indicate varied glycemic responses to the acute elevation of plasma zinc: 4 subjects showed little apparent effect; 3 subjects marginally increased either the area under the curve or time to peak and 1 subject (classified as suspect diabetic in the non-zinc condition) showed marked improvement in glycemic response following zinc ingestion. Their preliminary results suggest that blood glucose clearance may be affected in some individuals by the acute elevation of plasma zinc

  12. Seals and sealing handbook

    CERN Document Server

    Flitney, Robert K

    2007-01-01

    Wherever machinery operates there will be seals of some kind ensuring that the machine remains lubricated, the fluid being pumped does not leak, or the gas does not enter the atmosphere. Seals are ubiquitous, in industry, the home, transport and many other places. This 5th edition of a long-established title covers all types of seal by application: static, rotary, reciprocating etc. The book bears little resemblance to its predecessors, and Robert Flitney has re-planned and re-written every aspect of the subject. No engineer, designer or manufacturer of seals can afford to be without this uniq

  13. Gas laser tube and method of fabricating same

    International Nuclear Information System (INIS)

    Garman, L.E.

    1975-01-01

    An improved gas laser tube is fabricated by counter boring the ends of a tubular aluminum extrusion having an inner tubular portion supported from an outer tubular portion via the intermediary of a plurality of radially directed support vanes or legs. Metallic transverse walls are sealed across the ends of the tubular extrusion to define the ends of a gas tight metallic envelope. An electrically insulative glow discharge tube is axially disposed within and supported by the inner tubular portion of the extrusion in axial alignment with an optical resonator of the laser tube. (U.S.)

  14. A vacuum-sealed, gigawatt-class, repetitively pulsed high-power microwave source

    Science.gov (United States)

    Xun, Tao; Fan, Yu-wei; Yang, Han-wu; Zhang, Zi-cheng; Chen, Dong-qun; Zhang, Jian-de

    2017-06-01

    A compact L-band sealed-tube magnetically insulated transmission line oscillator (MILO) has been developed that does not require bulky external vacuum pump for repetitive operations. This device with a ceramic insulated vacuum interface, a carbon fiber array cathode, and non-evaporable getters has a base vacuum pressure in the low 10-6 Pa range. A dynamic 3-D Monte-Carlo model for the molecular flow movement and collision was setup for the MILO chamber. The pulse desorption, gas evolution, and pressure distribution were exactly simulated. In the 5 Hz repetition rate experiments, using a 600 kV diode voltage and 48 kA beam current, the average radiated microwave power for 25 shots is about 3.4 GW in 45 ns pulse duration. The maximum equilibrium pressure is below 4.0 × 10-2 Pa, and no pulse shortening limitations are observed during the repetitive test in the sealed-tube condition.

  15. Leakage test evaluation used for qualification of iodine-125 seeds sealing

    International Nuclear Information System (INIS)

    Feher, Anselmo; Rostelato, Maria E.C.M.; Zeituni, Carlos A.; Calvo, Wilson A.P.; Somessari, Samir L.; Moura, Joao A.; Moura, Eduardo S.; Souza, Carla D.; Rela, Paulo R.

    2009-01-01

    The prostate cancer is a problem of public health in Brazil, and the second cause of cancer deaths in men, exceeded only by lung cancer. Among the possible treatments available for prostate cancer is brachytherapy, in which small seeds containing Iodine-125 radioisotope are implanted in the prostate. The seed consists of a sealed titanium tube measuring 0.8 mm external diameter and 4.5 mm in length, containing a central silver wire with adsorbed Iodine-125. The tube sealing is made with titanium at the ends, using electric arc welding or laser process. This sealing must be leakage-resistant and free of cracks, therefore avoiding the Iodine-125 to deposit in the silver wire to escape and spread into the human body. To ensure this problem does not occur, rigorous leakage tests, in accordance with the standard Radiation protection - Sealed Radioactive Sources - leakage Test Methods - ISO 9978, should be applied. The aim of this study is to determine, implement and evaluate the leakage test to be used in the Iodine-125 seeds production, in order to qualify the sealing procedure. The standard ISO 9978 presents a list of tests to be carried out according to the type of source. The preferential methods for brachytherapy sources are soaking and helium. To assess the seeds leakage, the method of immersion test at room temperature was applied. The seeds are considered leakage-free if the detected activity does not exceed the 185 Bq (5 nCi). An Iodine standard was prepared and its value determined in a sodium iodide detector. A liquid scintillation counter was calibrated with the standard for seeds leakage tests. Forty-eight seeds were welded for these tests. (author)

  16. Bioavailability of zinc from sweet potato roots and leaves

    International Nuclear Information System (INIS)

    Baiden, H.N.; Ercanli-Huffman, F.G.

    1986-01-01

    Bioavailability of zinc from sweet potato (SP) roots and leaves were determined, by extrinsic labeling technique, in rats fed control and zinc deficient diets. Weanling male Sprague Dawley (SD) rats (60-75g) were divided into 4 groups, and fed laboratory chow, a control diet (ad libitum and pair fed) and a zinc deficient diet, for 4 weeks. Each group then was divided into at least 2 sub groups, containing 6 rats, which were intubated with one of 3 tubing solutions extrinsically labeled with 65 Zn; baked sweet potato roots (BSPR), raw sweet potato leaves (RSPL) and cooked sweet potato leaves (CSPL). Five hours after intubation the rats were sacrificed, blood, liver, testes, spleen, heart, brain, thymus and lungs were removed. Feces, urine, and GI tract contents were collected and their 65 Zn activity was determined in a gamma counter. In all treatment groups zinc bioavailability from BSPR, RSPL or CSPL were not significantly different. Zinc deficient rats absorbed significantly more (P 65 Zn (86-90% of the dose), regardless of type of tubing solution than the pairfed or control animals (35-58% of the dose). The highest retention of 65 Zn was found in the liver (12-20% of absorbed dose), GI tract (6-17% of absorbed dose), kidney (2-8% of absorbed dose), and blood (1-5% of absorbed dose). The lowest retention was found in the brain, heart, thymus and testes. (< 1% of absorbed dose)

  17. Electronic versus traditional chest tube drainage following lobectomy

    DEFF Research Database (Denmark)

    Lijkendijk, Marike; Licht, Peter B; Neckelmann, Kirsten

    2015-01-01

    thoracic surgery, we conducted a randomized controlled trial (RCT) investigating chest tube duration and length of hospitalization. METHODS: Patients undergoing lobectomy were included in a prospective open label RCT. A strict algorithm was designed for early chest tube removal, and this decision...... was delegated to staff nurses. Data were analysed by Cox proportional hazard regression model adjusting for lung function, gender, age, BMI, video-assisted thoracic surgery (VATS) or open surgery and presence of incomplete fissure or pleural adhesions. Time was distinguished as possible (optimal) and actual.......014). CONCLUSIONS: Electronic drainage systems did not reduce chest tube duration or length of hospitalization significantly compared with traditional water seal drainage when a strict algorithm for chest tube removal was used. This algorithm allowed delegation of chest tube removal to staff nurses, and in some...

  18. Tube-in-shell heat exchangers

    International Nuclear Information System (INIS)

    Richardson, J.

    1976-01-01

    Tube-in-shell heat exchangers normally comprise a bundle of parallel tubes within a shell container, with a fluid arranged to flow through the tubes in heat exchange with a second fluid flowing through the shell. The tubes are usually end supported by the tube plates that separate the two fluids, and in use the tube attachments to the tube plates and the tube plates can be subject to severe stress by thermal shock and frequent inspection and servicing are required. Where the heat exchangers are immersed in a coolant such as liquid Na such inspection is difficult. In the arrangement described a longitudinally extending central tube is provided incorporating axially spaced cylindrical tube plates to which the opposite ends of the tubes are attached. Within this tube there is a tubular baffle that slidably seals against the wall of the tube between the cylindrical tube plates to define two co-axial flow ducts. These ducts are interconnected at the closed end of the tube by the heat exchange tubes and the baffle comprises inner and outer spaced walls with the interspace containing Ar. The baffle is easily removable and can be withdrawn to enable insertion of equipment for inspecting the wall of the tube and tube attachments and to facilitate plugging of defective tubes. Cylindrical tube plates are believed to be superior for carrying pressure loads and resisting the effects of thermal shock. Some protection against thermal shock can be effected by arranging that the secondary heat exchange fluid is on the tube side, and by providing a thermal baffle to prevent direct impingement of hot primary fluid on to the cylindrical tube plates. The inner wall of the tubular baffle may have flexible expansible region. Some nuclear reactor constructions incorporating such an arrangement are described, including liquid metal reactors. (U.K.)

  19. A broken fenestrated tracheostomy tube fragment removed from the ...

    African Journals Online (AJOL)

    Tracheostomy tubes are composed of various materials: metals. – copper, silver, steel, nickel, zinc, polyvinyl chloride (PVC) and silicone.9 Multiple factors ... corrosive cleaning solutions and weakly corrosive alkaline bronchial secretions.

  20. Reactions of organic zinc- and cadmium elementoxides with ethylene oxide

    International Nuclear Information System (INIS)

    Dodonov, V.A.; Krasnov, Yu.N.

    1980-01-01

    Studied are reactions of triphenylmethoxy, -triphenylsiloxyethylzinc and -cadmium with ethylene oxide in ratio of 1:1. Reactions have been carried out in tolyene solutions in ampules sealed in argon atmosphere. It is found that interaction of triphenylsiloxy-, triphenylmethoxyethylcadmium and triphenylsiloxyethylzinc with ethylene oxide occurs at the metal-carbon bond with formation of implantation products. Triphenylmethoxyethylzinc reacts with ethylene oxide both at the metal-carbon and metal-oxygen bonds. Alkoxytriphenylsiloxyderivatives of zinc and cadmium are thermally instable and decompose under the conditions of reaction (130 deg C) with migration of phenyl group from silicon to zinc or cadmium, giving alkoxyphenylderivative and with bensene splitting out

  1. Pressure Actuated Leaf Seals for Improved Turbine Shaft Sealing

    Science.gov (United States)

    Grondahl, Clayton

    2006-01-01

    This presentation introduces a shaft seal in which leaf seal elements are constructed from slotted shim material formed and layered into a frusto-conical assembly. Limited elastic deflection of seal leaves with increasing system pressure close large startup clearance to a small, non-contacting, steady state running clearance. At shutdown seal elements resiliently retract as differential seal pressure diminishes. Large seal clearance during startup and shutdown provides a mechanism for rub avoidance. Minimum operating clearance improves performance and non-contacting operation promises long seal life. Design features of this seal, sample calculations at differential pressures up to 2400 psid and benefit comparison with brush and labyrinth seals is documented in paper, AIAA 2005 3985, presented at the Advanced Seal Technology session of the Joint Propulsion Conference in Tucson this past July. In this presentation use of bimetallic leaf material will be discussed. Frictional heating of bimetallic leaf seals during a seal rub can relieve the rub condition to some extent with a change in seal shape. Improved leaf seal rub tolerance is expected with bimetallic material.

  2. Design and operation of large straw-tube drift chamber planes

    Energy Technology Data Exchange (ETDEWEB)

    Bromberg, C; Brown, D; Huston, J; Maul, A; Miller, R; Nyugen, A; Sorrell, L; Yosef, C [Physics and Astronomy Dept., Michigan State Univ., East Lansing, MI (United States); Mani, S [Physics Dept., Univ. of California, Davis, CA (United States); Choudhary, B C; Kapoor, V; Shivpuri, R [Dept. of Physics and Astrophysics, Delhi Univ. (India); Baker, W; DeSoi, W; Johnstone, C; Kourbanis, I; Lukens, P; Skow, D; Wu, G H [Fermilab, Batavia, IL (United States); Alverson, G; Chang, P; Dlugosz, W; Faissler, W; Garelick, D; Glaubman, M; Lirakis, C; Pothier, E; Yasuda, T [Dept. of Physics, Northeastern Univ., Boston, MA (United States); Gutierrez, P [Dept. of Physics and Astronomy, Univ. of Oklahoma, Norman, OK (United States); Hartman, K; Oh, B Y; Toothacker, W; Whitmore, J [Dept. of Physics, Pennsylvania State Univ., University Park, PA (United States); Blusk, S R; Chung, W H; Engels, E Jr; Shepard, P F; Weerasundara, D D.S. [Dept. of Physics and

    1991-10-01

    We describe the design, construction and operation of a straw-tube drift chamber consisting of four X and four Y planes of 16 mm diameter straw-tubes, each 280 cm long. Straws were glued together for rigidity and were mounted into a frame which served as a gas manifold and maintained wire-to-wire precision. A novel conductive gasket was used to seal the tubes and provide electrical contact to the aluminized surface of the straws. The chamber has been successfully used in a high rate experiment (E706 at Fermilab) and has achieved its design resolution of better than 250 {mu}m per tube averaged over the whole chamber. (orig.).

  3. Performance of a tagged neutron inspection system (TNIS) based on portable sealed generators

    International Nuclear Information System (INIS)

    Nebbia, G.; Pesente, S.; Lunardon, M.; Viesti, G.; LeTourneur, P.; Heuveline, F.; Mangeard, M.; Tcheng, C.

    2004-01-01

    A portable sealed neutron generator has been modified to produce 14MeV tagged neutron beams with an embedded YAP:Ce scintillation detector. The system has been tested by detecting the coincident gamma-rays produced in the irradiation of a graphite sample by means of a standard NaI(Tl) scintillator. Time resolution of about δt=4-5ns (FWHM) has been measured. The sealed neutron tube has been operated up to 10 7 neutron/s. Possible applications in non-destructive assays and future developments of the Tagged Neutron Inspection System concept are discussed

  4. Endovascular Aneurysm Repair and Sealing (EVARS): A Useful Adjunct in Treating Challenging Morphology

    Energy Technology Data Exchange (ETDEWEB)

    Harrison, Gareth J., E-mail: garethjamesharrison@yahoo.co.uk; Antoniou, George A., E-mail: antoniou.ga@hotmail.com; Torella, Francesco, E-mail: francesco.torella@rlbuht.nhs.uk; McWilliams, Richard G., E-mail: richard.mcwilliams@rlbuht.nhs.uk; Fisher, Robert K., E-mail: robert.fisher@rlbuht.nhs.uk [Royal Liverpool University Hospital, Liverpool Vascular and Endovascular Service (United Kingdom)

    2016-04-15

    An 81-year-old male with previous open abdominal aortic aneurysm repair presented with asymptomatic large pseudoaneurysms at both ends of an open surgical tube graft. Endovascular aneurysm sealing (EVAS) in combination with the iliac limbs of a standard endovascular aneurysm repair (EVAR) successfully excluded both pseudoaneurysms from circulation. We describe the combination of elements of EVAS and EVAR and have termed this endovascular aneurysm repair and sealing (EVARS). EVARS has the advantage of harnessing the benefits of endobag sealing in aortic necks unsuitable for standard EVAR whilst providing the security of accurate stent placement within short common iliac arteries. In conclusion, EVAS may be combined with standard endovascular iliac limbs and is a possible treatment option for pseudoaneurysm following open aneurysm repair.

  5. Biocompatibility of RealSeal, its primer and AH Plus implanted in subcutaneous connective tissue of rats

    Directory of Open Access Journals (Sweden)

    Fabiana Soares Grecca

    2011-02-01

    Full Text Available OBJECTIVE: This study tested rat connective tissue response to RealSeal, RealSeal primer or AH Plus after 7, 15, 30, 60 and 90 days of implantation. MATERIAL AND METHODS: Thirty Wistar rats had subcutaneous sockets created on their back and received four implants each of polyethylene tubes containing one of the materials tested according to the groups: AH (AH Plus Sealer; RS (RealSeal Sealer; RP (RealSeal Primer; CG (control group - empty tube. After histological processing, sections were analyzed to identify the presence of neutrophils, lymphocytes and plasma cells, eosinophils, macrophages and giant cells, as well as fibrous capsule and abscesses, by an examiner using light microscope. Kruskal-Wallis and multiple-comparisons test were used for statistical analysis. Significance level was set at 5%. RESULTS: Lymphoplasmacytic infiltrate scores significantly higher than those of the control group were observed at 14 and 60 days in AH group, and at 90 days in RS group (p<0.05. There were no differences in terms of presence of macrophages, giant cells, eosinophils, neutrophils or fibrosis. AH Plus group scored higher for abscesses at 7 days than after any other period (p=0.031. RP group scored higher for lymphoplasmacytic infiltrate at 14 days than at 90 days (p=0.04. CONCLUSION: The main contribution of this study was to demonstrate that issues involved with tissue tolerance of a Resilon-containing sealer, RealSeal Sealer, cannot be attributed to its primer content.

  6. Wire-in-tube structure fabricated by single capillary electrospinning via nanoscale Kirkendall effect: the case of nickel-zinc ferrite.

    Science.gov (United States)

    Fu, Jiecai; Zhang, Junli; Peng, Yong; Zhao, Changhui; He, Yongmin; Zhang, Zhenxing; Pan, Xiaojun; Mellors, Nigel J; Xie, Erqing

    2013-12-21

    Wire-in-tube structures have previously been prepared using an electrospinning method by means of tuning hydrolysis/alcoholysis of a precursor solution. Nickel-zinc ferrite (Ni0.5Zn0.5Fe2O4) nanowire-in-nanotubes have been prepared as a demonstration. The detailed nanoscale characterization, formation process and magnetic properties of Ni0.5Zn0.5Fe2O4 nanowire-in-nanotubes has been studied comprehensively. The average diameters of the outer tubes and inner wires of Ni0.5Zn0.5Fe2O4 nanowire-in-nanotubes are around 120 nm and 42 nm, respectively. Each fully calcined individual nanowire-in-nanotube, either the outer-tube or the inner-wire, is composed of Ni0.5Zn0.5Fe2O4 monocrystallites stacked along the longitudinal direction with random orientation. The process of calcining electrospun polymer composite nanofibres can be viewed as a morphologically template nucleation and precursor diffusion process. This allows the nitrates precursor to diffuse toward the surface of the nanofibres while the oxides (decomposed from hydroxides and nitrates) products diffuse to the core region of the nanofibres; the amorphous nanofibres transforming thereby into crystalline nanowire-in-nanotubes. In addition, the magnetic properties of the Ni0.5Zn0.5Fe2O4 nanowire-in-nanotubes were also examined. It is believed that this nanowire-in-nanotube (sometimes called core-shell) structure, with its uniform size and well-controlled orientation of the long nanowire-in-nanotubes, is particularly attractive for use in the field of nano-fluidic devices and nano-energy harvesting devices.

  7. VAK III. Seals and sealing system

    International Nuclear Information System (INIS)

    d'Agraives, B.C.; Dal Cero, G.; Debeir, R.; Mascetti, E.; Toornvliet, J.; Volcan, A.

    1986-01-01

    This report presents the VAK III seals and sealing system, which have been used over a period of two years at the Kahl nuclear facility (Federal Republic of Germany), where field tests and feasibility studies were conducted in order to offer a possible solution for the sealing of LWR fuel assemblies. It has been prepared with the aim of an assessment study to be done at the IAEA. It gives all characteristics and technical descriptions for: the sealing principle, the seal construction, the operating tools, the data processing, the drawings, the publications related to that seal. The main points of progress are: the Strong Random Internal Defects (STRID) incorporated in the seals, allowing the obtention of a good signature stability; the Integrity Check on the Seal Status (broken or not) obtained through a decisive mechanical improvement: the Double Breakage Integrity Check (DOBRIC) and with a better ultrasonic evidence of that status; the provision of new function tools, allowing the performance of Identity Measurements in dry conditions (which means also at the manufacturer plant) or in deeper water (wet storage); the study and development of a new JRC VAK 45 Compact Instrument Box, in which all the measuring functions can be grouped and incorporating an autonomous Minicomputer offering to the Inspection the possibility of performing, on the spot, Correlation and Decision processes. The general benefit of such a feasibility study should be to convince the potential users that such a Safeguards Sealing System can be studied for slightly - or largely - different other applications, provided that the Basic and Operating Functions required to the system be clearly defined, possibly after a common agreement would be stated

  8. Development of containers sealing system like part of surveillance program of the vessel in nuclear power plants

    International Nuclear Information System (INIS)

    Romero C, J.; Hernandez C, R.; Fernandez T, F.; Rocamontes A, M.; Perez R, N.

    2009-10-01

    The owners of nuclear power plants should be demonstrate that the embrittlement effects by neutronic radiation do not commit the structural integrity from the pressure vessel of nuclear reactors, during conditions of routine operation and below postulate accident. For this reason, there are surveillance programs of vessels of nuclear power plants, in which are present surveillance capsules. A surveillance capsule is compound by the support, six containers for test tubes and dosimeters. The containers for test tubes are of two types: rectangular container for test tubes, Charpy V and Cylindrical Container for tension test tubes. These test tubes are subject to a same or bigger neutronic flow to that of vessel, being representative of vessel mechanical conditions. The test tubes are rehearsed to watch over the increase of embrittlement that presents the vessel. This work describes the development of welding system to seal the containers for test tubes, these should be filled with helium of ultra high purity, to a pressure of an atmosphere. In this system the welding process Gas Tungsten Arc Welding is used, a hermetic camera that allows to place the containers with three grades of freedom, a vacuum subsystem and pressure, high technology equipment's like: power source with integrated computer, arc starter of high frequency, helium flow controller, among others. Finally, the advances in the inspection system for the qualification of sealing system are mentioned, system that should measure the internal pressure of containers and the helium purity inside these. (Author)

  9. A comparison of the sealing ability of various temporary restorative materials to seal the access cavity: An in vitro study

    Directory of Open Access Journals (Sweden)

    Aji Markose

    2016-01-01

    Full Text Available Introduction: In multiple-appointment root canal treatment, a temporary filling material is used to seal the access cavity between visits. The primary function of this material is to prevent the contamination of the root canal system by fluids, organic debris, and bacteria from the oral cavity. Material and Methods: A total of fifty extracted noncarious unrestored human maxillaryanterior teeth with intact crowns and roots were selected The canals were instrumented using stepback technique and sodium hypochlorite (3% and hydrogen peroxide (3% were used as irrigants for each specimen alternatively. The coronal two-thirds of each canal were flared using Gates-Glidden drills up to no. 3 size and obturated with Gutta-percha using zinc oxide-eugenol (ZnOE as sealer. The teeth were then randomly selected and divided into six groups out of which four were experimental groups and two control groups. The teeth were then immersed in 2% methylene blue dye solution for 3 days. All sealing materials and Gutta-percha were gently removed from the walls of the canal, and the entire circumference of the canal wall examined for dye penetration. Results: The lowest mean leakage was in the Fermit-N group followed by Cavit-W, ZnOE, intermediate restorative materials (IRM, and positive control. Conclusion: Fermit-N showed better sealing ability compared to cavit, ZnOE and IRM.

  10. Manufacturing process for the metal ceramic hybrid fuel cladding tube

    International Nuclear Information System (INIS)

    Jung, Yang Il; Kim, Sun Han; Park, Jeong Yong

    2012-01-01

    For application in LWRs with suppressed hydrogen release, a metal-ceramic hybrid cladding tube has been proposed. The cladding consists of an inner zirconium tube and outer SiC fiber matrix SiC ceramic composite. The inner zirconium allows the matrix to remain fully sealed even if the ceramic matrix cracks through. The outer SiC composite can increase the safety margin by taking the merits of the SiC itself. However, it is a challenging task to fabricate the metal-ceramic hybrid tube. Processes such as filament winding, matrix impregnation, and surface costing are additionally required for the existing Zr based fuel cladding tubes. In the current paper, the development of the manufacturing process will be introduced

  11. Manufacturing process for the metal ceramic hybrid fuel cladding tube

    Energy Technology Data Exchange (ETDEWEB)

    Jung, Yang Il; Kim, Sun Han; Park, Jeong Yong [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of)

    2012-10-15

    For application in LWRs with suppressed hydrogen release, a metal-ceramic hybrid cladding tube has been proposed. The cladding consists of an inner zirconium tube and outer SiC fiber matrix SiC ceramic composite. The inner zirconium allows the matrix to remain fully sealed even if the ceramic matrix cracks through. The outer SiC composite can increase the safety margin by taking the merits of the SiC itself. However, it is a challenging task to fabricate the metal-ceramic hybrid tube. Processes such as filament winding, matrix impregnation, and surface costing are additionally required for the existing Zr based fuel cladding tubes. In the current paper, the development of the manufacturing process will be introduced.

  12. Sealing of ceramic SOFC-components with glass seals; Fuegen von keramischen Komponenten der Hochtemperatur-Brennstoffzellen mittels Glas- und Glaskeramikloten

    Energy Technology Data Exchange (ETDEWEB)

    Schillig, Cora

    2012-07-10

    -ceramics of the following systems CaO-MgO-Al{sub 2}O{sub 3}-SiO{sub 2} and BaO-Al{sub 2}O{sub 3}-SiO{sub 2}-B{sub 2}O{sub 3} show promising results. Special test assemblies for the determination of electrical conductivity and leak rate are set up for characterization. Finally, different selected sealing systems are tested under operating conditions in a bench-scale stack. Inside the SOFC-generator an additional gastight seal is needed between several dense and porous Al{sub 2}O{sub 3}-ceramic parts used for the gas supply, before the gas hits the fuel cells. Twenty four dense tubes with a length of 1 m and a porous plate were sealed as proof of concept with a seal based on the following oxides Al{sub 2}O{sub 3}-SiO{sub 2}-K{sub 2}O-CaO and with a thermal expansion coefficient between 8 and 9 . 10{sup -6}K{sup -1}.

  13. Cover-gas seals: 11-LMFBR seal-test program

    International Nuclear Information System (INIS)

    Steele, O.P. III; Horton, P.H.

    1977-01-01

    The objective of the Cover Gas Seal Material Development Program is to perform the engineering development required to provide reliable seals for LMFBR application. Specific objectives are to verify the performance of commercial solid cross-section and inflatable seals under reactor environments including radiation, to develop advanced materials and configurations capable of achieving significant improvement in radioactive gas containment and seal temperature capabilities, and to optimize seal geometry for maximum reliability and minimal gas permeation

  14. Sealed source and device design safety testing. Volume 4: Technical report on the findings of Task 4, Investigation of sealed source for paper mill digester

    International Nuclear Information System (INIS)

    Benac, D.J.; Iddings, F.A.

    1995-10-01

    This report covers the Task 4 activities for the Sealed Source and Device Safety testing program. SwRI was contracted to investigate a suspected leaking radioactive source that was installed in a gauge that was on a paper mill digester. The actual source that was leaking was not available, therefore, SwRI examined another source. SwRI concluded that the encapsulated source examined by SwRI was not leaking. However, the presence of Cs-137 on the interior and exterior of the outer encapsulation and hending tube suggests that contamination probably occurred when the source was first manufactured, then installed in the handling tube

  15. EFFECT OF SEALED MUNICIPAL WASTE LANDFILL ON THE QUALITY OF UNDERGROUND WATER

    Directory of Open Access Journals (Sweden)

    Elżbieta Halina Grygorczuk-Petersons

    2016-01-01

    Full Text Available The aim of the study was to evaluate the impact of the landfill on the groundwater environment. The assessment of water status in the region of landfill sealed with a layer of clay with a thickness of 0.5 m, was based on the own research and monitoring received from the municipal office, and conducted in 2007–2010. Waters flowing out of the landfill revealed an increase in pollution indicators such as: total organic carbon (TOC, concentrations of PAHs and heavy metals including zinc, cadmium, and chromium. It was demonstrated that the landfill sealed with a clay layer does not reduce the outflow of leachate to groundwater, but also that the purity of these waters is influenced by increased agricultural activity in the areas adjacent to the landfill.

  16. Radioactive sealed sources production process for industrial radiography

    International Nuclear Information System (INIS)

    Santos, Paulo de S.; Ngunga, Daniel M.G.; Camara, Julio R.; Vasquez, Pablo A.S.

    2017-01-01

    providing products and services to the private and governmental Brazilian users of industrial radiography and nucleonic control systems. Radioactive sealed sources are commonly used in nondestructive tests as radiography to make inspections and verify the internal structure and integrity of materials and in nucleonic gauges to control level, density, viscosity, etc. in on-line industrial processes. One of the most important activities carried out by this laboratory is related to the inspection of source projectors devices used in industrial radiography and its constituent parts as well as remote handle control assembly drive cable and guide tube systems. The laboratory also provide for the users iridium-192, cobalt-60 and selenium-75 sealed sources and performs quality control tests replacing spent or contaminated radiative sources. All discard of radioactive source is treated as radioactive waste. Additionally, administrative and commercial processes and protocols for exportation and transport of radioactive material are developed by specialized departments. In this work are presented the mean processes and procedures used by the Sealed Source Production Laboratory such as the arrival of the radioactive material to the laboratory and the source projectors, mechanical inspections, source loading, source leaking tests, etc. (author)

  17. Radioactive sealed sources production process for industrial radiography

    Energy Technology Data Exchange (ETDEWEB)

    Santos, Paulo de S.; Ngunga, Daniel M.G.; Camara, Julio R.; Vasquez, Pablo A.S., E-mail: psantos@ipen.br, E-mail: hobeddaniel@gmail.com, E-mail: jrcamara@ipen.br, E-mail: pavsalva@ipen.br [Instituto de Pesquisas Energética s e Nucleares (IPEN/CNEN-SP), São Paulo, SP (Brazil)

    2017-07-01

    providing products and services to the private and governmental Brazilian users of industrial radiography and nucleonic control systems. Radioactive sealed sources are commonly used in nondestructive tests as radiography to make inspections and verify the internal structure and integrity of materials and in nucleonic gauges to control level, density, viscosity, etc. in on-line industrial processes. One of the most important activities carried out by this laboratory is related to the inspection of source projectors devices used in industrial radiography and its constituent parts as well as remote handle control assembly drive cable and guide tube systems. The laboratory also provide for the users iridium-192, cobalt-60 and selenium-75 sealed sources and performs quality control tests replacing spent or contaminated radiative sources. All discard of radioactive source is treated as radioactive waste. Additionally, administrative and commercial processes and protocols for exportation and transport of radioactive material are developed by specialized departments. In this work are presented the mean processes and procedures used by the Sealed Source Production Laboratory such as the arrival of the radioactive material to the laboratory and the source projectors, mechanical inspections, source loading, source leaking tests, etc. (author)

  18. Mechanical seals

    CERN Document Server

    Mayer, E

    1977-01-01

    Mechanical Seals, Third Edition is a source of practical information on the design and use of mechanical seals. Topics range from design fundamentals and test rigs to leakage, wear, friction and power, reliability, and special designs. This text is comprised of nine chapters; the first of which gives a general overview of seals, including various types of seals and their applications. Attention then turns to the fundamentals of seal design, with emphasis on six requirements that must be considered: sealing effectiveness, length of life, reliability, power consumption, space requirements, and c

  19. Sealing device

    Science.gov (United States)

    Garcia-Crespo, Andres Jose

    2013-12-10

    A sealing device for sealing a gap between a dovetail of a bucket assembly and a rotor wheel is disclosed. The sealing device includes a cover plate configured to cover the gap and a retention member protruding from the cover plate and configured to engage the dovetail. The sealing device provides a seal against the gap when the bucket assemply is subjected to a centrifugal force.

  20. Vapour galvanizing (Sherardizing) of copper with zinc

    Energy Technology Data Exchange (ETDEWEB)

    Wortelen, Dietbert; Bracht, Hartmut [Westfaelische Wilhelms-Universitaet Muenster (Germany); Natrup, Frank; Graf, Wolfram [Bodycote Waermebehandlung GmbH, Sprockhoevel (Germany)

    2010-07-01

    Using a vapour galvanizing technique called Sherardizing we investigated the growth kinetics and coefficients of zinc copper phases. For this purpose polished (OFHC)-copper plates and zinc powder have been sealed in quartz ampoules under inert gas atmospheres and annealed at a temperature range between 300 and 410 C. In order to study the coating thickness and the phase composition, cross sections were prepared, which have been analyzed by means of optical microscopy and scanning electron microscopy. We were able to demonstrate that the coating thickness is a function of the parabolic time law and that the formed coatings are composed of two layers referring to the ordered {beta}-CuZn and {gamma}-Cu{sub 5}Zn{sub 8}-phases. To enhance the coating quality, small amounts of ZnCl{sub 2} were added to the zinc powder. It was observed that the coating thickness decreased with increasing ZnCl{sub 2}. Experiments with variable Ar-pressure demonstrated a reduced coating growth with increasing pressures. Further measurements with ZnCl{sub 2} were performed to check whether an electrochemical mechanism is involved in the coating process.

  1. Zinc injection in German PWR plants

    International Nuclear Information System (INIS)

    Streit, K.

    2004-01-01

    Operating experience acquired at PWR NNPs shows that zinc injection at low concentrations of 5 ppb is a very effective source term reduction measure. This method does not lead to any operating restrictions or other negative effects on plant systems and components. The nuclear industry has been very successful in reducing radiation exposures within the past two decades. Annual exposures could be significantly decreased and are now at a level of around 1 man-Sv per plant and year. This great success can mainly be attributed to the general commitment of plant operators to maintaining radiation exposures of workers in the controlled access area as low as reasonably achievable (ALARA principle). The ALARA principle, of course, also implies evaluation of the economic benefit of radiation protection measures. Radiation source term reduction has drawn increasing attention of plant operators in recent years. For the new PWRs cobalt-based alloys in the primary system have successively been eliminated already at the design and construction phase within the last decade. Use of wear-resistant cobalt-free substitute materials in combination with the general use of advanced alloys for the steam generator tubing of PWRs resulted in low values for the two most common sources of plant radiation fields, namely 58 Co and 60 Co. Investigations showed that the beneficial effect of zinc can be related to its high affinity for mixed spinel oxide phases, resulting in the following two basic effects: -Zinc is incorporated preferentially into the oxide layer on primary system surfaces and thus reduces pickup of 58 Co and 60 Co and - Zinc can displace cobalt isotopes from existing oxide layers. In German PWRs with Incoloy 800 steam generator tubing material (Ni-content -32%), the observed reductions correspond to a decrease in dose rates of around 10 to 15% per year and thus follow, as predicted, the half-life time of 60 Co. Overall reductions in high radiation areas are now in the range of

  2. Sealing Failure Analysis on V-Shaped Sealing Rings of an Inserted Sealing Tool Used for Multistage Fracturing Processes

    Directory of Open Access Journals (Sweden)

    Gang Hu

    2018-06-01

    Full Text Available The inserted sealing tool is a critical downhole implement that is used to balance the downhole pressure in multistage fracturing operations and prevent fracturing fluid from overflow and/or backward flow. The sealing ring of an inserted sealing tool plays an important role in downhole sealing since a sealing failure would ail the fracturing operation. In order to improve the sealing performance and reduce the potential fracturing failures, this research aims to investigate the influence of V-shaped sealing ring geometries on sealing performance. Constitutive experiments of rubber materials were carried out and the parameters of the constitutive relationship of rubber materials were obtained. A two-dimensional axisymmetric model considering the sealing ring has been established and influences are investigated with considerations of various system parameters and operating conditions. It is found that the stresses concentrated at the shoulder and inner vertex of the sealing ring have direct impact on the damage of the sealing rings under operational conditions. Moreover, the sealing interference, among several other factors, greatly affects the life of the sealing ring. A new design of the sealing ring is suggested with optimized geometric parameters. Its geometric parameters are the edge height of 5 mm, the vertex angle of 90°–100°, and the interference of 0.1 mm, which show a better performance and prolonged operation life of the sealing ring.

  3. Development of Self-Luminous Glass Tube (SLGT) Manufacturing Technology

    International Nuclear Information System (INIS)

    Kim, Kwang Sin; Kim, Kyeong Sook; Chung, Eun Su; Song, Kyu Min; Lee, Sook Kyung; Son, Soon Hwan

    2005-01-01

    Tritium produced from the Wolsong Tritium Removal Facility (WTRF) will be a radioactive waste when it is stored in the vault inside the WTRF, which requires maintenance cost and is a troublesome waste such that it cannot be sent to the radioactive waste disposal facility. However, when tritium is utilized it can be valuable resource for many applications. As a starting point to utilize tritium we tried to domesticate the selfluminous glass tube (SLGT) manufacturing technology. As a hydrogen isotope, tritium has similar chemical properties to hydrogen but slightly different physical properties. Due to its unstable nature, tritium emits beta rays, which are streams of electrons, with 0∼18.6 keV (5.7 keV in average) energies and 12.323 years of a half-life. The energy level of tritium is relatively low and the biological effects of tritium to the human body are not significant, which makes tritium a popular radioactive isotope for use in industries. The electrons in a beta ray collide with phosphor to produce light so that tritium sealed in phosphor coated glass tubes can make the tubes glow without an external supply of energy. To manufacture these SLGTs, 4 core technologies are needed: coating technology, tritium injection technology, laser sealing/cutting technology and tritium handling technology

  4. Cover gas seals: FFTF-LMFBR seal test program

    International Nuclear Information System (INIS)

    Kurzeka, W.; Oliva, R.; Welch, T.S.; Shimazaki, T.

    1974-01-01

    The objectives of this program are to: (1) conduct static and dynamic tests to demonstrate or determine the mechanical performance of full-size (cross section) FFTF fuel transfer machine and reactor vessel head seals intended for use in a sodium vapor-inert gas environment, (2) demonstrate that these FFTF seals or new seal configurations provide acceptable fission product and cover gas retention capabilities at Clinch River Breeder Reactor Plant (CRBRP) operating environmental conditions other than radiation, and (3) develop improved seals and seal technology for the CRBRP to support the national objective to reduce all atmospheric contaminations to low levels

  5. Actively-stabilized photomultiplier tube base for vacuum operation

    International Nuclear Information System (INIS)

    Bryan, M.A; Morris, C.L.; Idzorek, G.C.

    1992-01-01

    An actively stabilized photomultiplier tube (PMT) base design for an Amperex XP-2262B PMT is described. Positive-negative-positive transistors are used as low-impedance current sources to maintain constant voltages on the last three dynodes. This technique results in a highly stable, low-power tube base ideal for use with low-duty-factor beams, such as those found at the Clinton P. Anderson Meson Physics Facility. Furthermore, because of the low power usage of this large design, these bases can be sealed in a heat-conductive, electrically insulating material and used in a vacuum

  6. Fuel cell integral bundle assembly including ceramic open end seal and vertical and horizontal thermal expansion control

    Science.gov (United States)

    Zafred, Paolo R [Murrysville, PA; Gillett, James E [Greensburg, PA

    2012-04-24

    A plurality of integral bundle assemblies contain a top portion with an inlet fuel plenum and a bottom portion containing a base support, the base supports a dense, ceramic air exhaust manifold having four supporting legs, the manifold is below and connects to air feed tubes located in a recuperator zone, the air feed tubes passing into the center of inverted, tubular, elongated, hollow electrically connected solid oxide fuel cells having an open end above a combustion zone into which the air feed tubes pass and a closed end near the inlet fuel plenum, where the open end of the fuel cells rest upon and within a separate combination ceramic seal and bundle support contained in a ceramic support casting, where at least one flexible cushion ceramic band seal located between the recuperator and fuel cells protects and controls horizontal thermal expansion, and where the fuel cells operate in the fuel cell mode and where the base support and bottom ceramic air exhaust manifolds carry from 85% to all of the weight of the generator.

  7. Failure analysis and seal life prediction for contacting mechanical seals

    Science.gov (United States)

    Sun, J. J.; He, X. Y.; Wei, L.; Feng, X.

    2008-11-01

    Fault tree analysis method was applied to quantitatively investigate the causes of the leakage failure of mechanical seals. It is pointed out that the change of the surface topography is the main reasons causing the leakage of mechanical seals under the condition of constant preloads. Based on the fractal geometry theory, the relationship between the surface topography and working time were investigated by experiments, and the effects of unit load acting on seal face on leakage path in a mechanical seal were analyzed. The model of predicting seal life of mechanical seals was established on the basis of the relationship between the surface topography and working time and allowable leakage. The seal life of 108 mechanical seal operating at the system of diesel fuel storage and transportation was predicted and the problem of the condition monitoring for the long-period operation of mechanical seal was discussed by this method. The research results indicate that the method of predicting seal life of mechanical seals is feasible, and also is foundation to make scheduled maintenance time and to achieve safe-reliability and low-cost operation for industrial devices.

  8. Ceramic Seal.

    Energy Technology Data Exchange (ETDEWEB)

    Smartt, Heidi A. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Romero, Juan A. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Custer, Joyce Olsen [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Hymel, Ross W. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Krementz, Dan [Savannah River Site (SRS), Aiken, SC (United States). Savannah River National Lab. (SRNL); Gobin, Derek [Savannah River Site (SRS), Aiken, SC (United States). Savannah River National Lab. (SRNL); Harpring, Larry [Savannah River Site (SRS), Aiken, SC (United States). Savannah River National Lab. (SRNL); Martinez-Rodriguez, Michael [Savannah River Site (SRS), Aiken, SC (United States). Savannah River National Lab. (SRNL); Varble, Don [Savannah River Site (SRS), Aiken, SC (United States). Savannah River National Lab. (SRNL); DiMaio, Jeff [Tetramer Technologies, Pendleton, SC (United States); Hudson, Stephen [Tetramer Technologies, Pendleton, SC (United States)

    2016-11-01

    Containment/Surveillance (C/S) measures are critical to any verification regime in order to maintain Continuity of Knowledge (CoK). The Ceramic Seal project is research into the next generation technologies to advance C/S, in particular improving security and efficiency. The Ceramic Seal is a small form factor loop seal with improved tamper-indication including a frangible seal body, tamper planes, external coatings, and electronic monitoring of the seal body integrity. It improves efficiency through a self-securing wire and in-situ verification with a handheld reader. Sandia National Laboratories (SNL) and Savannah River National Laboratory (SRNL), under sponsorship from the U.S. National Nuclear Security Administration (NNSA) Office of Defense Nuclear Nonproliferation Research and Development (DNN R&D), have previously designed and have now fabricated and tested Ceramic Seals. Tests have occurred at both SNL and SRNL, with different types of tests occurring at each facility. This interim report will describe the Ceramic Seal prototype, the design and development of a handheld standalone reader and an interface to a data acquisition system, fabrication of the seals, and results of initial testing.

  9. Ceramic Seal

    International Nuclear Information System (INIS)

    Smartt, Heidi A.; Romero, Juan A.; Custer, Joyce Olsen; Hymel, Ross W.; Krementz, Dan; Gobin, Derek; Harpring, Larry; Martinez-Rodriguez, Michael; Varble, Don; DiMaio, Jeff; Hudson, Stephen

    2016-01-01

    Containment/Surveillance (C/S) measures are critical to any verification regime in order to maintain Continuity of Knowledge (CoK). The Ceramic Seal project is research into the next generation technologies to advance C/S, in particular improving security and efficiency. The Ceramic Seal is a small form factor loop seal with improved tamper-indication including a frangible seal body, tamper planes, external coatings, and electronic monitoring of the seal body integrity. It improves efficiency through a self-securing wire and in-situ verification with a handheld reader. Sandia National Laboratories (SNL) and Savannah River National Laboratory (SRNL), under sponsorship from the U.S. National Nuclear Security Administration (NNSA) Office of Defense Nuclear Nonproliferation Research and Development (DNN R&D), have previously designed and have now fabricated and tested Ceramic Seals. Tests have occurred at both SNL and SRNL, with different types of tests occurring at each facility. This interim report will describe the Ceramic Seal prototype, the design and development of a handheld standalone reader and an interface to a data acquisition system, fabrication of the seals, and results of initial testing.

  10. Mechanical seal assembly

    Science.gov (United States)

    Kotlyar, Oleg M.

    2001-01-01

    An improved mechanical seal assembly is provided for sealing rotating shafts with respect to their shaft housings, wherein the rotating shafts are subject to substantial axial vibrations. The mechanical seal assembly generally includes a rotating sealing ring fixed to the shaft, a non-rotating sealing ring adjacent to and in close contact with the rotating sealing ring for forming an annular seal about the shaft, and a mechanical diode element that applies a biasing force to the non-rotating sealing ring by means of hemispherical joint. The alignment of the mechanical diode with respect to the sealing rings is maintained by a series of linear bearings positioned axially along a desired length of the mechanical diode. Alternative embodiments include mechanical or hydraulic amplification components for amplifying axial displacement of the non-rotating sealing ring and transferring it to the mechanical diode.

  11. Mechanical Seal Assembly

    Energy Technology Data Exchange (ETDEWEB)

    Kotlyar, Oleg M.

    1999-06-18

    An improved mechanical seal assembly is provided for sealing rotating shafts with respect to their shaft housings, wherein the rotating shafts are subject to substantial axial vibrations. The mechanical seal assembly generally includes a rotating sealing ring fixed to the shaft, a non-rotating sealing ring adjacent to and in close contact with the rotating sealing ring for forming an annular seal about the shaft, and a mechanical diode element that applies a biasing force to the non-rotating sealing ring by means of hemispherical joint. The alignment of the mechanical diode with respect to the sealing rings is maintained by a series of linear bearings positioned axially along a desired length of the mechanical diode. Alternative embodiments include mechanical or hydraulic amplification components for amplifying axial displacement of the non-rotating sealing ring and transferring it to the mechanical diode.

  12. Glass sealing

    Energy Technology Data Exchange (ETDEWEB)

    Brow, R.K.; Kovacic, L.; Chambers, R.S. [Sandia National Labs., Albuquerque, NM (United States)

    1996-04-01

    Hernetic glass sealing technologies developed for weapons component applications can be utilized for the design and manufacture of fuel cells. Design and processing of of a seal are optimized through an integrated approach based on glass composition research, finite element analysis, and sealing process definition. Glass sealing procedures are selected to accommodate the limits imposed by glass composition and predicted calculations.

  13. Investigation and recovery of unrecovered fuel pellets and cladding tube pieces

    International Nuclear Information System (INIS)

    Kobayashi, Keiji

    1980-01-01

    The total weight of the fuel pellets lost due to break was about 1206 g, and cladding tube pieces were about 217 g. Among these, the pellets of about 527 g and the cladding tube pieces of about 152 g were recovered when broken fuel rods were discovered. It is not desirable to leave these broken pieces as unrecovered in view of safety and the management of nuclear fuel materials. Kansai Electric Power Co., Inc., investigated the position and the amount of these pellets and cladding tube pieces for about a year, and recovered a part of them. The results were written in two reports. The objects of the investigation and recovery, and the method of recovery are explained. The UO 2 and zirconium recovered were 58.52 g and 369.58 g, respectively. The solid pellets were recovered from the reactor, fuel assemblies, a spent fuel pit and canals, and the content in sludge was recovered from other installations. The amounts of unrecovered pellets and cladding tube pieces in primary cooling water, coolant filters, sealing water filters, primary cooling pipes, waste resins and fuel assemblies were estimated. The problems concerning the recovery and estimation are pointed out. The results of estimating the amount of uranium in coolant filters and sealing water filters are useful to know the time of the occurrence of accident. (Kako, I.)

  14. A survey on serumic zinc levels of sheep in Miandoab Province in 2008

    Directory of Open Access Journals (Sweden)

    A.P Rezaei Saber

    2010-05-01

    Full Text Available Due to complexity of Zinc metabolism in the body, there is much interest to study this element. Every phase of growth and development requires Zinc. Zinc deficiency leads to many complications including reproduction and fertility disorders, weakness of the immune system and occurrence of secondary infections. In this study, blood samples were obtained from the jugular vein of 200 apparently healthy sheep of Miandoab province using venoject tubes in each season of the year (a total of 800 samples following age and gender determination. Based on the one-way analysis of variance, there was a significant difference (p

  15. Titanium condenser tubes--problems and their solutions for wider application to large surface condensers

    Energy Technology Data Exchange (ETDEWEB)

    Sato, S; Sugiyama, Y; Nagata, K; Namba, K; Shimono, M

    1978-01-01

    To meet the demand for high reliability condensers for thermal and nuclear power plants, especially for PWR plants, the condensers installed entirely with titanium tubes have been investigated and used. Some difficulties from conventional copper alloy tubes exist. Further investigations are necessary on three items: (1) tube vibration; (2) joining tubes to tube plate; (3) fouling (bio-fouling) control. Literature survey on the tube vibration suggests that the probability of tube vibration due to decreased stiffness of titanium tubes in comparison with conventional copper alloy tubes can be decreased by designing the proper span length between supports. Experiments on seal welding of tubes to a tube plate have successfully proved that pulsed TIG arc welding is applicable to get reliable and strong joints, even on site, by suitable countermeasures. Experiments on the fouling (bio-fouling) of titanium tubes in marine application reveal that the increased fouling of titanium tubes could be controlled by proper application of sponge ball cleaning.

  16. Final report of the borehole, shaft, and tunnel sealing test. Vol. 3

    International Nuclear Information System (INIS)

    Pusch, R.; Boergesson, L.; Ramqvist, G.

    1987-02-01

    Like the borehole and shaft plugging tests, the tunnel test gave evidence of the very effective sealing power of Na betonite. The test arrangement consisted of a 9 m long 1.5 m diameter steel tube surrounded by sand and cast in concrete plugs at each end. These plugs contained bentonite forming 'O-ring' sealings at the concrete/rock interface. The test had the form of injecting water into the sand and measuring the leakage that took place through the adjacent rock and along the plug. It was concluded that the drop in leakage from more than 200 l at 100 kPa water pressure early in the test to 75 l at 3 MPa pressure at the end was due partly to the swelling pressure exerted by the bentonite on the rock and by penetration of bentonite into water-bearing rock fractures. The major sealing process appears to be the establishment of a very tight bentonite/rock interface. (orig./HP)

  17. Feedwater heater tube-to-tubesheet connections

    International Nuclear Information System (INIS)

    Yokell, S.

    1993-01-01

    This paper discusses some practical aspects of expanded, welded, and welded-and-expanded feedwater heater tube-to-tubesheet joints. It outlines elastic-plastic tube expanding theory. It examines uniform-pressure-expanded tube joint strength and correlating roller-expanded joint strength with wall reduction and rolling torque. For materials subject to stress-corrosion cracking (SCC), it recommends heat treating tube ends before expanding. For materials subject to fatigue and tube-end cracking, it advocates two-stage expanding: (1) expanding enough to create firm tube-hole contact over the full tubesheet thickness; and (2) re-expanding at full pressure or torque. The paper emphasizes the desirability of segregating heats of tubing, mapping the tube-heat locations and making the heat map a permanent part of the heater maintenance file. It recommends when to provide TEMA/HEI Power Plant Standard annular grooves for roller-expanding and provides an equation for determining optimum groove width for uniform-pressure expanding. The paper also reviews welding requirements for welds of tubes to tubesheets. The review covers front-face welding before and after expanding and the reasons for welding first. It outlines current thinking about definitions of strength- and seal-welds of front-face welded joint in terms of their functions and load-carrying abilities. It presents a proposal for determining the required size of strength welds for use in Section VIII of the ASME Boiler and Pressure Vessel Code (the Code). It shows why welded-and-expanded feedwater heater tube-to-tubesheet joints should be full-strength and full-depth expanded. It makes recommendations for pressure- and leak-testing. This work also proposes the industry consider butt welding the tubes to the steam-side face of the tubesheet as a regular method of tube joining. The results of a survey of manufacturers practices are appended. 30 refs., 14 figs

  18. Sealing performance of a magnetic fluid seal for rotary blood pumps.

    Science.gov (United States)

    Mitamura, Yoshinori; Takahashi, Sayaka; Kano, Kentaro; Okamoto, Eiji; Murabayashi, Shun; Nishimura, Ikuya; Higuchi, Taka-Aki

    2009-09-01

    A magnetic fluid (MF) for a rotary blood pump seal enables mechanical contact-free rotation of the shaft and, hence, has excellent durability. The performance of a MF seal, however, has been reported to decrease in liquids. We have developed a MF seal that has a "shield" mechanism and a new MF with a higher magnetization of 47.9 kA/m. The sealing performance of the MF seal installed in a rotary blood pump was studied. Under the condition of continuous flow, the MF seal remained in perfect condition against a pressure of 298 mm Hg (pump flow rate: 3.96 L/min). The seal was also perfect against a pressure of 170 mm Hg in a continuous flow of 3.9 L/min for 275 days. We have developed a MF seal that works in liquid against clinically used pressures. The MF seal is promising as a shaft seal for rotary blood pumps.

  19. Management of Disused Sealed Sources in Hungary - 13077

    International Nuclear Information System (INIS)

    Kapitany, Sandor

    2013-01-01

    Since 1976 the spent and disused radioactive sources arisen in Hungary are stored in a central storage facility called Radioactive Waste Treatment and Disposal Facility operated by Public Limited Company for Radioactive Waste Management. The Facility is responsible for the record keeping, the waste acceptance procedure, the shipment and the storage or disposal (whether a certain source meets the waste acceptance criteria for disposal or not) of sources. Based on the more than 35 year old operation of the facility many experiences have been gathered regarding the technology for long-term storage of sources, the attitude of the users of sources, the evolution of the legislation and the national record keeping system. Recently a new legislation for the security of radioactive materials (including sources) was introduced, first in Central-Europe. It requires special security arrangements from the facility for transport and for storage. Due to the ongoing retrieval of radioactive waste formerly disposed of, partly containing sealed sources, there is a new challenge in the physical inventory control of historical waste. The paper would show the effect of the changes in the legislation system of record keeping or security on the users' attitude for discard of sources and on the management of the sources in the facility. The facility has a unique storage technology (shallow boreholes) in the narrow region. The sealed sources are placed into vertical pipes sunk into the surface. In the beginning, each of the sources were dropped into the pipe directly, recently they are placed in a metal tube first ensuring the retrieval. The lessons learned will be presented. There were several issues to introduce the new security arrangements (partly financially supported by US DOE) for storage and for transportation of sealed sources. These issues are addressed. In the past part of the sealed sources were disposed together with solid radioactive waste packaged in plastic bags. A waste

  20. Management of Disused Sealed Sources in Hungary - 13077

    Energy Technology Data Exchange (ETDEWEB)

    Kapitany, Sandor [PURAM, Puskas Tivadar street 11, Budaors, Pest 2040 (Hungary)

    2013-07-01

    Since 1976 the spent and disused radioactive sources arisen in Hungary are stored in a central storage facility called Radioactive Waste Treatment and Disposal Facility operated by Public Limited Company for Radioactive Waste Management. The Facility is responsible for the record keeping, the waste acceptance procedure, the shipment and the storage or disposal (whether a certain source meets the waste acceptance criteria for disposal or not) of sources. Based on the more than 35 year old operation of the facility many experiences have been gathered regarding the technology for long-term storage of sources, the attitude of the users of sources, the evolution of the legislation and the national record keeping system. Recently a new legislation for the security of radioactive materials (including sources) was introduced, first in Central-Europe. It requires special security arrangements from the facility for transport and for storage. Due to the ongoing retrieval of radioactive waste formerly disposed of, partly containing sealed sources, there is a new challenge in the physical inventory control of historical waste. The paper would show the effect of the changes in the legislation system of record keeping or security on the users' attitude for discard of sources and on the management of the sources in the facility. The facility has a unique storage technology (shallow boreholes) in the narrow region. The sealed sources are placed into vertical pipes sunk into the surface. In the beginning, each of the sources were dropped into the pipe directly, recently they are placed in a metal tube first ensuring the retrieval. The lessons learned will be presented. There were several issues to introduce the new security arrangements (partly financially supported by US DOE) for storage and for transportation of sealed sources. These issues are addressed. In the past part of the sealed sources were disposed together with solid radioactive waste packaged in plastic bags. A

  1. Concepts for operational period panel seal design at the Waste Isolation Pilot Plant

    International Nuclear Information System (INIS)

    Hansen, F.D.; Lin, M.S.; Van Sambeek, L.L.

    1993-07-01

    Concepts for underground panel or drift seals at the Waste Isolation Pilot Plant are developed to satisfy sealing requirements of the operational period. The concepts are divided into two groups. In the ''NOW'' group, design concepts are considered in which a sleeve structure is installed in the panel access immediately after excavation and before waste is emplaced. In the ''LATER'' group, no special measures are taken during excavation or before waste emplacement; the seal is installed at a later date, perhaps up to 35 years after the drift is excavated. Three concepts are presented in both the NOW and LATER groups. A rigid sleeve, a yielding sleeve, and steel rings with inflatable tubes are proposed as NOW concepts. One steel ring concept and two concrete monoliths are proposed for seals emplaced in older drifts. Advantages and disadvantages are listed for each concept. Based on the available information, it appears most feasible to recommend a LATER concept using a concrete monolith as a preferred seal for the operational period. Each concept includes the potential of remedial grout and/or construction of a chamber that could be used for monitoring leakage from a closed panel during the operational period. Supporting in situ demonstrations of elements of the concepts are recommended

  2. Influence of liquid holdup in steam generator U-tubes on small break LOCA severity

    International Nuclear Information System (INIS)

    Leonard, M.T.; Perryman, J.L.; Johnson, G.W.

    1983-01-01

    The severity of small cold leg break loss-of-coolant accidents has been shown to be influenced by liquid holdup in steam generator U-tubes during pump suction loop seal formation in two experiments performed in the Semiscale Mod-2A facility. The core coolant level can be depressed lower than previously thought possible due to a positive hydrostatic head across the steam generators caused by delayed drainage of liquid from the upflow side of the U-tubes. The significance of a lower core coolant level depression is the potential for a more severe temperature excursion occurring during the coolant boiloff phase subsequent to loop seal clearing and prior to accumulator injection. Presented in this paper are the experimental data analysis and supporting computer code calculations that led to these conclusions

  3. Electronic self-monitoring seal

    International Nuclear Information System (INIS)

    Campbell, J.W.

    1978-01-01

    The Electronic Self-Monitoring Seal is a new type of security seal which allows continuous verification of the seal's identity and status. The identity information is a function of the individual seal, time, and seal integrity. A description of this seal and its characteristics are presented. Also described are the use cycle for the seal and the support equipment for programming and verifying the seal

  4. Inboard seal mounting

    Science.gov (United States)

    Hayes, John R. (Inventor)

    1983-01-01

    A regenerator assembly for a gas turbine engine has a hot side seal assembly formed in part by a cast metal engine block having a seal recess formed therein that is configured to supportingly receive ceramic support blocks including an inboard face thereon having a regenerator seal face bonded thereto. A pressurized leaf seal is interposed between the ceramic support block and the cast metal engine block to bias the seal wear face into sealing engagement with a hot side surface of a rotary regenerator matrix.

  5. Security seal

    Science.gov (United States)

    Gobeli, Garth W.

    1985-01-01

    Security for a package or verifying seal in plastic material is provided by a print seal with unique thermally produced imprints in the plastic. If tampering is attempted, the material is irreparably damaged and thus detectable. The pattern of the imprints, similar to "fingerprints" are recorded as a positive identification for the seal, and corresponding recordings made to allow comparison. The integrity of the seal is proved by the comparison of imprint identification records made by laser beam projection.

  6. Mechanical seal program

    International Nuclear Information System (INIS)

    Lowery, G.B.

    1983-01-01

    The experimental plans and timing for completion of the mechanical seal program for both the slurry and transfer pumps are given. The slurry pump seal program will be completed by April 1984 with turnover of two seals in pumps to SRP Tank 15H. Transfer pump seal design will be released for plant use by May 1984. Also included are various other pump and seal related tests

  7. Secondary seal effects in hydrostatic non-contact seals for reactor coolant pump shaft

    International Nuclear Information System (INIS)

    Fujita, T.; Koga, T.; Tanoue, H.; Hirabayashi, H.

    1987-01-01

    The paper presents a seal flow analysis in a hydrostatic non-contact seal for a PWR coolant pump shaft. A description is given of the non-contact seal for the reactor coolant pump. Results are presented for a distortion analysis of the seal ring, along with the seal flow characteristics and the contact pressure profiles of the secondary seals. The results of the work confirm previously reported findings that the seal ring distortion is sensitive to the o-ring location (which was placed between the ceramic seal face and the seal ring retainer). The paper concludes that the seal flow characteristics and the tracking performance depend upon the dynamic properties of the secondary seal. (U.K.)

  8. Chest Tube Drainage of the Pleural Space: A Concise Review for Pulmonologists.

    Science.gov (United States)

    Porcel, José M

    2018-04-01

    Chest tube insertion is a common procedure usually done for the purpose of draining accumulated air or fluid in the pleural cavity. Small-bore chest tubes (≤14F) are generally recommended as the first-line therapy for spontaneous pneumothorax in non-ventilated patients and pleural effusions in general, with the possible exception of hemothoraces and malignant effusions (for which an immediate pleurodesis is planned). Large-bore chest drains may be useful for very large air leaks, as well as post-ineffective trial with small-bore drains. Chest tube insertion should be guided by imaging, either bedside ultrasonography or, less commonly, computed tomography. The so-called trocar technique must be avoided. Instead, blunt dissection (for tubes >24F) or the Seldinger technique should be used. All chest tubes are connected to a drainage system device: flutter valve, underwater seal, electronic systems or, for indwelling pleural catheters (IPC), vacuum bottles. The classic, three-bottle drainage system requires either (external) wall suction or gravity ("water seal") drainage (the former not being routinely recommended unless the latter is not effective). The optimal timing for tube removal is still a matter of controversy; however, the use of digital drainage systems facilitates informed and prudent decision-making in that area. A drain-clamping test before tube withdrawal is generally not advocated. Pain, drain blockage and accidental dislodgment are common complications of small-bore drains; the most dreaded complications include organ injury, hemothorax, infections, and re-expansion pulmonary edema. IPC represent a first-line palliative therapy of malignant pleural effusions in many centers. The optimal frequency of drainage, for IPC, has not been formally agreed upon or otherwise officially established. Copyright©2018. The Korean Academy of Tuberculosis and Respiratory Diseases.

  9. Design optimization of seal structure for sealing liquid by magnetic fluids

    International Nuclear Information System (INIS)

    Liu Tonggang; Cheng Yusheng; Yang Zhiyi

    2005-01-01

    The durability of the magnetic fluid seal clearly decreases when sealing another liquid because of the interface instability caused by the applied magnetic field and the velocity difference of the two liquids. With an intention to establish a stable interface during sealing liquid, a new magnetic fluid seal was developed in this paper. The parameters of the structure were optimized by a simulation apparatus. And the magnetic fluid seal designed based on the optimum parameters shows good performance and long life for sealing lubricating oil

  10. Casingless down-hole for sealing an ablation volume and obtaining a sample for analysis

    Science.gov (United States)

    Noble, Donald T.; Braymen, Steven D.; Anderson, Marvin S.

    1996-10-01

    A casing-less down hole sampling system for acquiring a subsurface sample for analysis using an inductively coupled plasma system is disclosed. The system includes a probe which is pushed into the formation to be analyzed using a hydraulic ram system. The probe includes a detachable tip member which has a soil point mad a barb, with the soil point aiding the penetration of the earth, and the barb causing the tip member to disengage from the probe and remain in the formation when the probe is pulled up. The probe is forced into the formation to be tested, and then pulled up slightly, to disengage the tip member and expose a column of the subsurface formation to be tested. An instrumentation tube mounted in the probe is then extended outward from the probe to longitudinally extend into the exposed column. A balloon seal mounted on the end of the instrumentation tube allows the bottom of the column to be sealed. A source of laser radiation is emitted from the instrumentation tube to ablate a sample from the exposed column. The instrumentation tube can be rotated in the probe to sweep the laser source across the surface of the exposed column. An aerosol transport system carries the ablated sample from the probe to the surface for testing in an inductively coupled plasma system. By testing at various levels in the down-hole as the probe is extracted from the soil, a profile of the subsurface formation may be obtained.

  11. A randomized non-crossover study comparing the ProSeal and Classic laryngeal mask airway in anaesthetized children.

    Science.gov (United States)

    Lopez-Gil, M; Brimacombe, J; Garcia, G

    2005-12-01

    We tested the hypothesis that ease of insertion, oropharyngeal leak pressure, fibreoptic position, gastric insufflation, and the frequency of mucosal trauma differ between the ProSeal laryngeal mask airway (PLMA) and the classic laryngeal mask airway (cLMA) in anaesthetized children. For the PLMA, we also assessed the ease of gastric tube placement via the PLMA drain tube and measure residual gastric volume. 240 consecutive ASA I-III children aged 1-16 yr were randomized for airway management with the ProSeal or cLMA. The time taken to provide an effective airway, the number of insertion attempts, fibreoptic position of the airway tube and frequency of mucosal trauma were similar, but oropharyngeal leak pressure was higher (33 vs 26 cm H(2)O, Ptube insertion was successful at the first attempt in 106 of 120, and at the second attempt in 14 of 120. The mean (sd; range) value for residual gastric volume was 2.2 (5.9; 0-30) ml. There were no differences in performance among sizes for the PLMA and the cLMA. We conclude that ease of insertion, fibreoptic position, and frequency of mucosal trauma are similar for the PLMA and cLMA in children, but oropharyngeal leak pressure is higher and gastric insufflation less common for the PLMA. Gastric tube insertion has a high success rate, provided the PLMA is correctly positioned.

  12. Seal arrangement

    International Nuclear Information System (INIS)

    Dempsey, J.D.

    1978-01-01

    A hydraulically balanced face type shaft seal is provided in which the opening and closing seal face areas retain concentricity with each other in the event of lateral shaft displacement. The seal arrangement is for a vertical high pressure pump, indented for use in the cooling system of a nuclear reactor. (Auth.)

  13. Seroprevalence of Antibodies against Seal Influenza A(H10N7) Virus in Harbor Seals and Gray Seals from the Netherlands.

    Science.gov (United States)

    Bodewes, Rogier; Rubio García, Ana; Brasseur, Sophie M; Sanchez Conteras, Guillermo J; van de Bildt, Marco W G; Koopmans, Marion P G; Osterhaus, Albert D M E; Kuiken, Thijs

    2015-01-01

    In the spring and summer 2014, an outbreak of seal influenza A(H10N7) virus infection occurred among harbor seals (Phoca vitulina) off the coasts of Sweden and Denmark. This virus subsequently spread to harbor seals off the coasts of Germany and the Netherlands. While thousands of seals were reported dead in Sweden, Denmark and Germany, only a limited number of seals were found dead in the Netherlands. To determine the extent of exposure of seals in the Netherlands to influenza A/H10N7 virus, we measured specific antibody titers in serum samples from live-captured seals and seals admitted for rehabilitation in the Netherlands by use of a hemagglutination inhibition assay and an ELISA. In harbor seals in 2015, antibodies against seal influenza A(H10N7) virus were detected in 41% (32 out of 78) pups, 10% (5 out of 52) weaners, and 58% (7 out of 12) subadults or adults. In gray seals (Halichoerus grypus) in 2015, specific antibodies were not found in the pups (n = 26), but in 26% (5 out of 19) of the older animals. These findings indicate that, despite apparent low mortality, infection with seal influenza A(H10N7) virus was geographically widespread and also occurred in grey seals.

  14. Zinc fingers, zinc clusters, and zinc twists in DNA-binding protein domains

    International Nuclear Information System (INIS)

    Vallee, B.L.; Auld, D.S.; Coleman, J.E.

    1991-01-01

    The authors recognize three distinct motifs of DNA-binding zinc proteins: (i) zinc fingers, (ii) zinc clusters, and (iii) zinc twists. Until very recently, x-ray crystallographic or NMR three-dimensional structure analyses of DNA-binding zinc proteins have not been available to serve as standards of reference for the zinc binding sites of these families of proteins. Those of the DNA-binding domains of the fungal transcription factor GAL4 and the rat glucocorticoid receptor are the first to have been determined. Both proteins contain two zinc binding sites, and in both, cysteine residues are the sole zinc ligands. In GAL4, two zinc atoms are bound to six cysteine residues which form a zinc cluster akin to that of metallothionein; the distance between the two zinc atoms of GAL4 is ∼3.5 angstrom. In the glucocorticoid receptor, each zinc atom is bound to four cysteine residues; the interatomic zinc-zinc distance is ∼13 angstrom, and in this instance, a zinc twist is represented by a helical DNA recognition site located between the two zinc atoms. Zinc clusters and zinc twists are here recognized as two distinctive motifs in DNA-binding proteins containing multiple zinc atoms. For native zinc fingers, structural data do not exist as yet; consequently, the interatomic distances between zinc atoms are not known. As further structural data become available, the structural and functional significance of these different motifs in their binding to DNA and other proteins participating in the transmission of the genetic message will become apparent

  15. Utilization of a sealed-tube neutron generator for training and research

    International Nuclear Information System (INIS)

    Jonah, S.A.

    2000-01-01

    The development of a program in nuclear science and technology in Nigeria began in 1976 with the establishment of two research centers, namely, the Centre for Energy Research and Training, (CERT), Zaria and the Centre for Energy Research and Development (CERD), Ile-Ife. The choice of Neutron Activation Analysis (NAA) technique as a very effective method of training scientists in basic and applied nuclear research led to the purchase of two KAMAN A-711 Neutron Generators for the two research centers. At CERT, the neutron generator (code named ZARABUNG-1) was successfully installed and the first 14 MeV neutrons were produced through the technical assistance of the International Atomic Energy Agency (IAEA) in 1988. In 1991, a new tube-head was purchased and installed due to the expiration of the old tube. Following the completion of its permanent site, the neutron generator was re-located from the old site and re-installed at the permanent site of CERT in 1995. (author)

  16. Transfer of hydrogen and helium through corrugated, flexible tubes

    International Nuclear Information System (INIS)

    Schippl, K.

    2001-01-01

    The transfer of liquid gas or cold gas through corrugated tubes is an alternative to rigid systems for the use in reactor technique. Advantages: flexibility for easy installation; these tubes together with their associated terminations and hardware are assembled, leak-tested and evacuated at the factory. This permits simple and cost saving installation on site. All tubes are helium leak-tested with a sensitivity of 10E -9 mbar 1/sec. Following the leak test, the vacuum space is pumped down to the operation vacuum level and properly sealed. The vacuum integrity is guaranteed as a result of the high degree of cleanliness observed during production and from the use of a specially selected better material inside the vacuum space. Disadvantage: pressure is limited to 20 bar. To fulfil all rules of the reactor safety, different tests have to be done. Because of the longitudinal weld of the corrugated tube, a bursting test of different sizes gives the best information of the liability of this kind of tube. It can be shown that the bursting pressure of such a tube is more than 5 times higher than the max. working pressure

  17. Seal design alternatives study

    International Nuclear Information System (INIS)

    Van Sambeek, L.L.; Luo, D.D.; Lin, M.S.; Ostrowski, W.; Oyenuga, D.

    1993-06-01

    This report presents the results from a study of various sealing alternatives for the WIPP sealing system. Overall, the sealing system has the purpose of reducing to the extent possible the potential for fluids (either gas or liquid) from entering or leaving the repository. The sealing system is divided into three subsystems: drift and panel seals within the repository horizon, shaft seals in each of the four shafts, and borehole seals. Alternatives to the baseline configuration for the WIPP seal system design included evaluating different geometries and schedules for seal component installations and the use of different materials for seal components. Order-of-magnitude costs for the various alternatives were prepared as part of the study. Firm recommendations are not presented, but the advantages and disadvantages of the alternatives are discussed. Technical information deficiencies are identified and studies are outlined which can provide required information

  18. Serum calcium response following oral zinc oxide administrations in dairy cows

    DEFF Research Database (Denmark)

    Thilsing-Hansen, T; Jørgensen, R J; Thilsing, Trine

    2001-01-01

    Six non-pregnant cows were allocated into 3 groups. Group 1 comprised a pair of lactating cows, whereas groups 2 and 3 each comprised a pair of non-lactating cows. The cows in groups 1 and 2 were dosed intraruminally by stomach tube with zinc oxide at 120 mg Zn per kg of bodyweight at weekly...... intervals for a period of 33 days. Each cow received a total of 4 doses of zinc oxide. Group 3 served as non-treated control group. Blood samples were collected from all 6 cows daily. Serum was analysed for concentration of calcium. Within 12-24 h of each zinc oxide administration the serum calcium...... of the hypocalcaemic response decreased with the number of zinc oxide dosings. This effect was explained as a response from the stimulation of the calcium homeostatic mechanisms. In the Zn dosed non-lactating cows responses were similar but less clear. The perspective of these findings is discussed in relation...

  19. Tube bundle system: for monitoring of coal mine atmosphere.

    Science.gov (United States)

    Zipf, R Karl; Marchewka, W; Mohamed, K; Addis, J; Karnack, F

    2013-05-01

    A tube bundle system (TBS) is a mechanical system for continuously drawing gas samples through tubes from multiple monitoring points located in an underground coal mine. The gas samples are drawn via vacuum pump to the surface and are typically analyzed for oxygen, methane, carbon dioxide and carbon monoxide. Results of the gas analyses are displayed and recorded for further analysis. Trends in the composition of the mine atmosphere, such as increasing methane or carbon monoxide concentration, can be detected early, permitting rapid intervention that prevents problems, such as a potentially explosive atmosphere behind seals, fire or spontaneous combustion. TBS is a well-developed technology and has been used in coal mines around the world for more than 50 years. Most longwall coal mines in Australia deploy a TBS, usually with 30 to 40 monitoring points as part of their atmospheric monitoring. The primary uses of a TBS are detecting spontaneous combustion and maintaining sealed areas inert. The TBS might also provide mine atmosphere gas composition data after a catastrophe occurs in an underground mine, if the sampling tubes are not damaged. TBSs are not an alternative to statutory gas and ventilation airflow monitoring by electronic sensors or people; rather, they are an option to consider in an overall mine atmosphere monitoring strategy. This paper describes the hardware, software and operation of a TBS and presents one example of typical data from a longwall coal mine.

  20. Study on a corrosion products behavior with zinc injection in PWR primary circuit based on the crud investigation in actual plant

    International Nuclear Information System (INIS)

    Hisamune Kenji; Nambu Tohru; Akutagawa Daisuke; Nagata Nobuaki; Shimizu, Yuichi; Nagamine, Kunitaka; Kogawa Noritaka

    2012-09-01

    Zinc injection into the reactor coolant of Pressurized Water Reactor (PWR) is one of the most effective techniques for removing radioactive cobalt from the chromite type spinel oxides in the inner layer of reactor coolant component surfaces. Many documents have reported that zinc injection applied plants have generally achieved positive dose rate reduction effects for the reactor coolant components and piping. Tsuruga Nuclear Power Plant unit 2 (hereafter Tsuruga unit 2) which applied zinc injection in 2005 has also achieved good dose reduction effects in most primary coolant piping. However, some piping without dose-rate reduction effects exist, it has come to an issue to plan radiation exposure reduction measures for the works around relevant piping. To plan a reasonable dose-rate reduction measures for respective components and piping in primary systems, it is considered necessary to understand the dose-rate reduction effects of zinc injection mechanically. Therefore, the surface oxides/deposits on piping and fuel cladding tubes with operational histories under zinc injection were investigated. As a result of the investigation, the changes in specific aspects of oxide layers and CRUDs are found as follow: - Owing to long-term zinc injection, deposits and oxides on the primary coolant piping are extremely reduced, the boundary between the outer oxide layer and the inner oxide layer become unclear with the thinning of the outer oxide layers. - At a Pressurizer Spray Piping, the dose-rate increases than before zinc injection. The oxide layers have the same 3-layer construction as before zinc injection, and the surface concentration of the radioactive cobalt is high. - At the fuel cladding tube surfaces, what is observed is the amount of metal nickel decrease and the chromium composition increase in the spinel type oxide From these results, it is suggested that, the oxide layers composed principally of zinc chromite spinel grow up on the pipe surface with zinc

  1. Nuclear waste vault sealing

    International Nuclear Information System (INIS)

    Gyenge, M.

    1980-01-01

    A nuclear waste vault must be designed and built to ensure adequate isolation of the nuclear wastes from human contact. Consequently, after a vault has been fully loaded, it must be adequately sealed off to prevent radionuclide migration which may be provided by circulating groundwater. Vault sealing entails four major aspects, i.e.: (a) vault grouting; (b) borehole sealing; (c) buffer packing; and (d) backfilling. Of particular concern in vault sealing are the physical and chemical properties of the sealing material, its long-term durability and stability, and the techniques used for its emplacement. Present sealing technology and sealing materials are reviewed in terms of the particular needs of vault sealing. Areas requiring research and development are indicated

  2. Nozzle seal

    International Nuclear Information System (INIS)

    Herman, R.F.

    1977-01-01

    In an illustrative embodiment of the invention, a nuclear reactor pressure vessel, having an internal hoop from which the heated coolant emerges from the reactor core and passes through to the reactor outlet nozzles, is provided with sealing members operatively disposed between the outlet nozzle and the hoop. The sealing members are biased against the pressure vessel and the hoop and are connected by a leak restraining member establishing a leak-proof condition between the inlet and outlet coolants in the region about the outlet nozzle. Furthermore, the flexible responsiveness of the seal assures that the seal will not structurally couple the hoop to the pressure vessel

  3. Nozzle seal

    International Nuclear Information System (INIS)

    Walling, G.A.

    1977-01-01

    In an illustrative embodiment of the invention, a nuclear reactor pressure vessel, having an internal hoop from which the heated coolant emerges from the reactor core and passes through to the reactor outlet nozzles, is provided with sealing rings operatively disposed between the outlet nozzles and the hoop. The sealing rings connected by flexible members are biased against the pressure vessel and the hoop, establishing a leak-proof condition between the inlet and outlet coolants in the region about the outlet nozzle. Furthermore, the flexible responsiveness of the seal assures that the seal will not structurally couple the hoop to the pressure vessel. 4 claims, 2 figures

  4. Zinc Finger Takes on a Whole New Meaning: Reducing and Monitoring Zinc Blanks in the Isotope Lab

    Science.gov (United States)

    Wilkes, E. B.; Wasylenki, L. E.; Anbar, A. D.

    2010-12-01

    In terms of avoiding contamination, zinc is one of the most difficult elements to study isotopically. The reason for this is that zinc stearate is a very common mold release agent in the production of plastics, including those most often used in isotope geochemistry clean labs. While polyethylene bottles, polypropylene centrifuge tubes, pipette tips, and Kimwipes are all potential sources of contaminant zinc, by far the largest amount of zinc is introduced to the laboratory by gloves. Most items can be effectively rid of zinc by soaking in dilute hydrochloric acid, but gloves cannot be cleaned easily, and use of gloves can quickly lead to contamination on many surfaces throughout the lab. We recently conducted several experiments in which dissolved zinc was partly adsorbed onto synthetic Mn oxyhydroxide particles. The dissolved and adsorbed pools were separated by filtration, purified with ion exchange chemistry, and analyzed for isotope composition by MC-ICP-MS. We used a commercially purchased ICP standard solution both as our standard (delta66/64Zn = 0) and as the source of the zinc in the experiments. Whenever gloves were worn during purification, process blanks contained as much as 150 ng Zn, and both the dissolved and adsorbed pools of zinc came out enriched in heavy isotopes relative to the starting pool, contrary to our expectation of mass balance. When gloves were not worn, blanks were brands of vinyl gloves, including one brand recommended to us for being “low” in zinc, measured +10‰ relative to our standard. We therefore concluded that glove zinc contaminated most of our experimental samples. We were only able to see such clear evidence of contamination because (1) we were doing an experiment in which we expected one light and one heavy pool of zinc compared to our standard, and (2) we happened to use an ICP standard solution for delta = 0 that is strongly enriched in light isotopes relative to both brands of gloves. We caution others who measure

  5. Flexible ring seal

    International Nuclear Information System (INIS)

    Abbes, Claude; Gournier, Andre; Rouaud, Christian; Villepoix, Raymond de.

    1976-01-01

    The invention concerns a flexible metal ring seal, able to ensure a perfect seal between two bearings due to the crushing and elastic deformation properties akin to similar properties in elastomers. Various designs of seal of this kind are already known, particularly a seal made of a core formed by a helical wire spring with close-wound turns and with high axial compression ratio, closed on itself and having the shape of an annulus. This wire ring is surrounded by at least one envelope having at rest the shape of a toroidal surface of which the generating circle does not close on itself. In a particular design mode, the seal in question can include, around the internal spring, two envelopes of which one in contact with the spring is composed of a low ductility elastic metal, such as mild steel or stainless steel and the other is, on the contrary, made of a malleable metal, such as copper or nickel. The first envelope evenly distributes the partial crushing of the spring, when the seal is tightened, on the second envelope which closely fits the two surfaces between which the seal operates. The stress-crushing curve characteristic of the seal comprises two separate parts, the first with a relatively sharp slope corresponds to the start of the seal compression phase, enabling at least some of these curves to reach the requisite seal threshold very quickly, then, beyond this, a second part, practically flat, where the stress is appreciably constant for a wide operating bracket [fr

  6. Active Infrared Thermography for Seal Contamination Detection in Heat-Sealed Food Packaging

    Directory of Open Access Journals (Sweden)

    Karlien D’huys

    2016-11-01

    Full Text Available Packaging protects food products from environmental influences, assuring quality and safety throughout shelf life if properly performed. Packaging quality depends on the quality of the packaging material and of the closure or seal. A common problem possibly jeopardizing seal quality is the presence of seal contamination, which can cause a decreased seal strength, an increased packaging failure risk and leak formation. Therefore, early detection and removal of seal contaminated packages from the production chain is crucial. In this work, a pulsed-type active thermography method using the heated seal bars as an excitation source was studied for detecting seal contamination. Thermal image sequences of contaminated seals were recorded shortly after sealing. The detection performances of six thermal image processing methods, based on a single frame, a fit of the cooling profiles, thermal signal reconstruction, pulsed phase thermography, principal component thermography and a matched filter, were compared. High resolution digital images served as a reference to quantify seal contamination, and processed thermal images were mapped to these references. The lowest detection limit (equivalent diameter 0.60 mm was obtained for the method based on a fit of the cooling profiles. Moreover, the detection performance of this method did not depend strongly on the time after sealing at which recording of the thermal images was started, making it a robust and generally applicable method.

  7. Nuclear reactor sealing system

    International Nuclear Information System (INIS)

    McEdwards, J.A.

    1983-01-01

    A liquid metal-cooled nuclear reactor sealing system is disclosed. The nuclear reactor includes a vessel sealed at its upper end by a closure head. The closure head comprises at least two components, one of which is rotatable; and the two components define an annulus therebetween. The sealing system includes at least a first and second inflatable seal disposed in series in an upper portion of the annulus. The system further includes a dip seal extending into a body of insulation located adjacent a bottom portion of the closure head. The dip seal comprises a trough formed by a lower portion of one of the components, and a seal blade pendently supported from the other component and extending downwardly into the trough. A body of liquid metal is contained in the trough which submerges a portion of the seal blade. The seal blade is provided with at least one aperture located above the body of liquid metal for providing fluid communication between the annulus intermediate the dip seal and the inflatable seals, and a body of cover gas located inside the vessel. There also is provided means for introducing a purge gas into the annulus intermediate the inflatable seals and the seal blade. The purge gas is introduced in an amount sufficient to substantially reduce diffusion of radioactive cover gas or sodium vapor up to the inflatable seals. The purge gas mixes with the cover gas in the reactor vessel where it can be withdrawn from the vessel for treatment and recycle to the vessel

  8. The IRES electronic seal

    International Nuclear Information System (INIS)

    Autrusson, B.; Brochard, D.; Moreau, J.F.; Martin, J.C.

    2001-01-01

    In the framework of the French Support Program for the IAEA Safeguards, the 'Institut de Protection et de Surete Nucleaire' (IPSN), developed an electronic seal called Integrated and Reusable Electronic Seal (IRES) that enables independent verification by different inspectorates (IAEA, Euratom, and National Inspectorate). The seal can be remotely interrogated by radio frequency and integrated to other Containment/surveillance systems by serial line RS 485. Data are authenticated and the IRESMAG software manages in the seal reader all functionalities of the seal and records inspection data compatible with the IAEA's Seal Database. To perform this development, IPSN relies on industrial partners: SAPHYMO for the general architecture of the seal and the electronics, THALES for the authentication of data and the security of transmission. The main features of the IRES seal are the following: Interrogation by different inspectorate, allowing independent conclusions; Recording of events, including tampering, in a non-volatile memory; Authentication of data and enhanced security of the communication between the seal and the seal reader; Remote interrogation by an inspector or/and automatic for unattended systems or remote monitoring; Reusable after erasing the seal memory and replacement of the batteries

  9. Compliant seal development

    Science.gov (United States)

    Hendricks, Robert C.

    1993-10-01

    The compliant metallic seal combines the noncontact feature of the labyrinth seal, the low leakage of a mechanical seal, and the compliant nature of the brush seal. It consists of several thin metallic elements or leaves mounted within a ring which is press fit into the housing, and in form, sort of resembles a lip seal sections wiping the shaft. A second set of overlapping cover leaves are placed on top of the shaft riding leaves which reduces leakage and provides stiffness. The leaves can be straight or angle cut. The shaft riding fingers are designed with mismatched curvature to provide lift off similar to the Rayleigh lift pads in mechanical seals with leading edge clearances nearly twice those of the trailing edge as as shown by Fleming to be optimal for gas flows in convergent seal passages. Leading edge clearances range from 300 to 500 microinches. Balance pockets beneath the leaves provide fluid film feed to the 'Rayleigh lift' surface and the proper balance ratio (mechanical seal) when combined with the static pressure and film pressure. The leaves flex in the radial direction and accommodate thermomechanical behavior as well as axial motion and angular misalignment. In the static mode, there is a net closing force on the leaves. The seals were tested to 70 psi at speeds to 16,000 rpm or surface speeds to 330 fps and temperatures from ambient to 440 F. A slow cycle through the rig critical at 10,000 rpm induced a radial vibration response of 0.004 to 0.005 inch were accommodated by the seal. Preliminary performance data are encouraging demonstrating hydrodynamic liftoff and noncontacting operation at pressure and speeds typical of gas turbine engines. The leakage performance data are significantly better than commercial labyrinth and brush seals which should be expected as this design incorporates the features of the low leakage face or mechanical seal along with the flexibility of the brush configuration.

  10. Self-acting shaft seals

    Science.gov (United States)

    Ludwig, L. P.

    1978-01-01

    Self-acting seals are described in detail. The mathematical models for obtaining a seal force balance and the equilibrium operating film thickness are outlined. Particular attention is given to primary ring response (seal vibration) to rotating seat face runout. This response analysis reveals three different vibration models with secondary seal friction being an important parameter. Leakage flow inlet pressure drop and affects of axisymmetric sealing face deformations are discussed. Experimental data on self-acting face seals operating under simulated gas turbine conditions are given. Also a spiral groove seal design operated to 244 m/sec (800 ft/sec) is described.

  11. HMSRP Hawaiian Monk Seal Master Identification Records (seal)

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — This data set contains records of all individually identified Hawaiian monk seals since 1981. These seals were identified by PSD personnel and cooperating scientists...

  12. Sealing devices

    International Nuclear Information System (INIS)

    Coulson, R.A.

    1980-01-01

    A sealing device for minimising the leakage of toxic or radioactive contaminated environments through a biological shield along an opening through which a flexible component moves that penetrates the shield. The sealing device comprises an outer tubular member which extends over a length not less than the maximum longitudinal movement of the component along the opening. An inner sealing block is located intermediate the length of the component by connectors and is positioned in the bore of the outer tubular member to slide in the bore and effect a seal over the entire longitudinal movement of the component. The cross-section of the device may be circular and the block may be of polytetrafluoroethylene or of nylon impregnated with molybdenum or may be metallic. A number of the sealing devices may be combined into an assembly for a plurality of adjacent longitudinally movable components, each adapted to sustain a tensile load, providing the various drives of a master-slave manipulator. (author)

  13. Seal modification for a V-band

    International Nuclear Information System (INIS)

    Abbatiello, A.A.

    1975-10-01

    An aluminum gasket with a small volume added at one point has been developed and is recommended for sealing a leak in the HFIR HB-1 beam-tube flange. This type of gasket, in a symmetrical form, was originally tested and proposed in February, 1972. It has now been revised to fit a specific eroded area (found when the HFIR was disassembled for a scheduled major overhaul, after ten years of operation. The modified gasket consists of a ring made of 0.093-in.-diam wire with the normal contour increased to 1 / 8 in. 2 in the section at the cavity region and oriented to place this section over the eroded area. Special tools and viewers are available for checking its position

  14. Hermetically Sealed Compressor

    Science.gov (United States)

    Holtzapple, Mark T.

    1994-01-01

    Proposed hermetically sealed pump compresses fluid to pressure up to 4,000 atm (400 MPa). Pump employs linear electric motor instead of rotary motor to avoid need for leakage-prone rotary seals. In addition, linear-motor-powered pump would not require packings to seal its piston. Concept thus eliminates major cause of friction and wear. Pump is double-ended diaphragm-type compressor. All moving parts sealed within compressor housing.

  15. Day care PNL using 'Santosh-PGI hemostatic seal' versus standard PNL: A randomized controlled study.

    Science.gov (United States)

    Kumar, Santosh; Singh, Shivanshu; Singh, Prashant; Singh, Shrawan Kumar

    2016-01-01

    To compare the outcomes of tubeless day care PNL using hemostatic seal in the access tract versus standard PNL. It was a prospective randomized controlled study. Cases were randomized to either the day care group with hemostatic seal (DCS) or the control group where patients were admitted and a nephrostomy tube was placed at the conclusion of surgery. A total of 180 cases were screened and out of these, 113 were included in the final analysis. The stone clearance rates were comparable in both the groups. The mean drop in hemoglobin was significantly lower in DCS group than the control group (1.05 ±0.68 vs. 1.30 ±0.58 gm/dl, p = 0.038).Mean postoperative pain score, analgesic requirement (paracetamol) and duration of hospital stay were also significantly lower in the DCS group (3.79 ±1.23 vs. 6.12 ±0.96, 1.48 ±0.50 vs. 4.09 ±1.11 grams and 0.48 ±0.26 vs. 4.74 ±1.53 days respectively; p PNL with composite hemostatic tract seal is considered safe. It resulted in a significant reduction of blood loss and analgesic requirement with significantly reduced hospital stay, nephrostomy tube site morbidity and time required to resume normal activity when compared to the standard PNL. However, patients must be compliant with the given instructions and should have access to a health care facility, as few of them may need re-admission.

  16. Reinforced seal component

    International Nuclear Information System (INIS)

    Jeanson, G.M.; Odent, R.P.

    1980-01-01

    The invention concerns a seal component of the kind comprising a soft sheath and a flexible reinforcement housed throughout the entire length of the sheath. The invention enables O ring seals to be made capable of providing a radial seal, that is to say between two sides or flat collars of two cylindrical mechanical parts, or an axial seal, that is to say between two co-axial axisymmetrical areas. The seal so ensured is relative, but it remains adequately sufficient for many uses, for instance, to ensure the separation of two successive fixed blading compartments of axial compressors used in gas diffusion isotope concentration facilities [fr

  17. Numerical Investigation of the Effect of Radial Lip Seal Geometry on Sealing Performance

    Science.gov (United States)

    Tok, G.; Parlar, Z.; Temiz, V.

    2018-01-01

    Sealing elements are often needed in industry and especially in machine design. With the change and development of machine technology from day to day, sealing elements show continuous development and change in parallel with these developments. Many factors influence the performance of the sealing elements such as shaft surface roughness, radial force, lip geometry etc. In addition, the radial lip seals must have a certain pre-load and interference in order to provide a good sealing. This also affects the friction torque. Researchers are developing new seal designs to reduce friction losses in mechanical systems. In the presented study, the effect of the lip seal geometry on sealing performance will be examined numerically. The numerical model created for this purpose will be verified with experimental data firstly. In the numerical model, shaft and seal will be modeled as hyper-elastic in 2D and 3D. NBR (Nitrile Butadiene Rubber) as seal material will be analyzed for the rotating shaft state at constant speed by applying a uniform radial force.

  18. Development of Micro-welding Technology of Cladding Tube with Temperature Sensor for Nuclear Fuel Irradiation Test

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Soo Sung; Lee, C. Y.; Kim, W. K.; Lee, J. W.; Lee, D. Y

    2006-01-15

    Laser welding technology is widely used to fabricate some products of nuclear fuel in the nuclear industry. Especially, micro-laser welding is one of the key technology to be developed to fabricate precise products of fuel irradiation test. We have to secure laser welding technology to perform various instrumentations for fuel irradiation test. The instrumented fuel irradiation test at a research reactor is needed to evaluate the performance of the developed nuclear fuel. The fuel elements can be designed to measure the center line temperature of fuel pellets during the irradiation test by using temperature sensor. The thermal sensor was composed of thermocouple and sensor sheath. Micro-laser welding technology was adopted to seal between seal tube and sensor sheath with thickness of 0.15mm. The soundness of weld area has to be confirmed to prevent fission gas of the fuel from leaking out of the element during the fuel irradiation test. In this study, fundamental data for micro-laser welding technology was proposed to seal temperature sensor sheath of the instrumented fuel element. And, micro-laser welding for dissimilar metals between sensor sheath and seal tube was characterized by investigating welding conditions. Moreover, the micro-laser welding technology is closely related to advanced industry. It is expected that the laser material processing technology will be adopted to various applications in the industry.

  19. Reactor vessel sealing plug

    International Nuclear Information System (INIS)

    Dooley, R.A.

    1986-01-01

    This invention relates to an apparatus and method for sealing the cold leg nozzles of a nuclear reactor pressure vessel from a remote location during maintenance and inspection of associated steam generators and pumps while the pressure vessel and refueling canal are filled with water. The apparatus includes a sealing plug for mechanically sealing the cold leg nozzle from the inside of a reactor pressure vessel. The sealing plugs include a primary and a secondary O-ring. An installation tool is suspended within the reactor vessel and carries the sealing plug. The tool telescopes to insert the sealing plug within the cold leg nozzle, and to subsequently remove the plug. Hydraulic means are used to activate the sealing plug, and support means serve to suspend the installation tool within the reactor vessel during installation and removal of the sealing plug

  20. High pressure shaft seal

    International Nuclear Information System (INIS)

    Martinson, A.R.; Rogers, V.D.

    1980-01-01

    In relation to reactor primary coolant pumps, mechanical seal assembly for a pump shaft is disclosed which features a rotating seal ring mounting system which utilizes a rigid support ring loaded through narrow annular projections in combination with centering non-sealing O-rings which effectively isolate the rotating seal ring from temperature and pressure transients while securely positioning the ring to adjacent parts. A stationary seal ring mounting configuration allows the stationary seal ring freedom of motion to follow shaft axial movement up to 3/4 of an inch and shaft tilt about the pump axis without any change in the hydraulic or pressure loading on the stationary seal ring or its carrier. (author)

  1. Does the seal licensing system in Scotland have a negative impact on seal welfare?

    Directory of Open Access Journals (Sweden)

    Laetitia Nunny

    2016-08-01

    Full Text Available This study examined the licensing system that permits seal shooting in Scotland, which was established under Part 6 Conservation of Seals of the Marine (Scotland Act 2010. Four approaches were used: data were collated and analyzed from both the Scottish Government and Scottish Marine Animal Stranding Scheme; a survey was sent to current license holders and informal interviews were conducted with key stakeholder types. Between February 2011 and the end of October 2015, 1229 gray seals and 275 common seals were reported shot under license to the Scottish Government. The numbers of seals reported as shot has reduced year-on-year since the licensing system was put in place. While some license holders, notably fish farms, were using some non-lethal forms of deterrent to reduce seal-related damage, these were often used alongside seal shooting. Of the seals reported as shot to the Scottish Government, only a small percentage were also reported to the Scottish Marine Animal Stranding Scheme, despite this being a licensing requirement. Only 2.3% of the shot gray seals and 4.5% of the shot common seals were necropsied. There is evidence from these necropsies that some seals had not died instantly or had not been shot in the manner recommended by the Scottish Seal Management Code of Practice. These preliminary results show that more carcasses need to be recovered and necropsied if the welfare implications of current seal shooting practice are to be properly assessed. The current legislation does not specify closed seasons to protect breeding seals and thirty-five per cent of necropsied seals were pregnant gray seals. Seals have also been shot during their lactation periods when pups are dependent on their mothers. This raises significant welfare concerns. The re-introduction of closed seasons specific to each species of seal is recommended along with greater effort to deploy non-lethal methods. Independent assessment of the number of seals being killed

  2. SSME Seal Test Program: Test results for sawtooth pattern damper seal

    Science.gov (United States)

    Childs, D. W.

    1986-01-01

    Direct and transverse force coefficients for 11, sawtooth-pattern, and damper-seal configurations were examined. The designation damper seal uses a deliberately roughened stator and smooth rotor to increase the net damping force developed by a seal. The designation sawtooth-pattern refers to a stator roughness pattern. The sawtooth pattern yields axial grooves in the stator which are interrupted by spacer elements which act as flow constrictions or dams. All seals use the same smooth rotor and have the same, constant, minimum clearance. The stators examined the consequences of changes in the following design parameters: (1) axial-groove depth; (2) number of teeth: (3) number of sawtooth sections; (4) number of spacer elements; (5) dam width; (6) axially aligned sawtooth sections versus axially-staggered sawtooth sections; and (7) groove geometry. It is found that none of the sawtooth-pattern seal performs as well as the best round-hole-pattern seal. Maximum damping configurations for the sawtooth and round-hole-pattern stators have comparable stiffness performance. Several of the sawtooth pattern stators outperformed the best round-hole pattern seal.

  3. Circumferential shaft seal

    Science.gov (United States)

    Ludwig, L. P. (Inventor)

    1981-01-01

    A circumferential shaft seal comprising two sealing rings held to a rotating shaft by means of a surrounding elastomeric band is disclosed. The rings are segmented and are of a rigid sealing material such as carbon or a polyimide and graphite fiber composite.

  4. Sealing arrangement for radioactive material

    International Nuclear Information System (INIS)

    Gray, I.L.S.; Sievwright, R.W.T.; Elliott, J.C.

    1993-01-01

    A sealing arrangement for hermetically sealing two mating surfaces comprises two seals arranged to lie between the surfaces. Each seal provides hermetic sealing over a respective different temperature range and lie serially along the surfaces between the regions to be isolated. A main seal integrity test arrangement is provided in the form of a port and passage. This allows for the introduction of a fluid into or the evacuation of a region between the two seals to detect a leak. The port is also provided with at least two test port seals which seal with a plug. The plug is also provided with a test port to allow the integrity of the test port seal to be tested. (UK)

  5. Effect of Pneumoperitoneum and Lateral Position on Oropharyngeal Seal Pressures of Proseal LMA in Laparoscopic Urological Procedures.

    Science.gov (United States)

    Rustagi, Preeti; Patkar, Geeta A; Ourasang, Anil Kumar; Tendolkar, Bharati A

    2017-02-01

    A sustained and effective oropharyngeal sealing with supraglottic airway is required to maintain the ventilation during laparoscopic surgery. Previous studies have observed the Oropharyngeal Seal Pressure (OSP) for Proseal Laryngeal Mask Airway (PLMA) after pneumoperitoneum in supine and trendelenburg position, where PLMA was found to be an effective airway device. This study was conducted with ProSeal LMA, for laparoscopic Urologic procedures done in lateral position. To measure OSP in supine and lateral position and to observe the effect of pneumoperitoneum in lateral position on OSP. Secondary objectives were to assess adequacy of ventilation and incidence of adverse events. A total number of 25 patients of American Society of Anaesthesiologists (ASA) physical status II and I were enrolled. After induction of anaesthesia using a standardized protocol, PLMA was inserted. Ryle's tube was inserted through drain tube. The position of PLMA was confirmed with ease of insertion of Ryle's tube and fibreoptic grading of vocal cords. Patients were then put in lateral position. The OSP was measured in supine position. This value was baseline comparison for OSP in lateral position and that after pneumoperitoneum. We assessed the efficacy of PLMA for ventilation, after carboperitoneum in lateral position (peak airway pressure, End Tidal Carbon dioxide (EtCO 2 ), SPO 2 ). Incidence of adverse effects (displacement of device, gastric insufflation, regurgitation, coughing, sore throat, blood on device, trauma) was also noted. The OSP was above Peak Airway Pressure (PAP) in supine (22.1±5.4 and 15.4±4.49cm of H 2 O) and lateral position (22.6±5.3 and 16.1±4.6). After pneumoperitoneum, which was in lateral position, there was statistically significant (p-value <0.05) increase in both PAP (19.96±4.015) and OSP (24.32±4.98, p-value 0.03). There was no intraoperative displacement of PLMA. There was no event of suboptimal oxygenation. EtCO 2 was always within normal limits

  6. Severe service sealing solutions

    International Nuclear Information System (INIS)

    Metcalfe, R.; Wensel, R.

    1994-09-01

    Successful sealing usually requires much more than initial leak-tightness. Friction and wear must also be acceptable, requiring a good understanding of tribology at the sealing interface. This paper describes various sealing solutions for severe service conditions. The CAN2A and CAN8 rotary face seals use tungsten carbide against carbon-graphite to achieve low leakage and long lifetime in nuclear main coolant pumps. The smaller CAN6 seal successfully uses tungsten carbide against silicon carbide in reactor water cleanup pump service. Where friction in CANDU fuelling machine rams must be essentially zero, a hydrostatic seal using two silicon carbide faces is the solution. In the NRU reactor moderator pumps, where pressure is much lower, eccentric seals that prevent boiling at the seal faces are giving excellent service. All these rotary face seals rely on supplementary elastomer seals between their parts. An integrated engineering approach to high performance sealing with O-rings is described. This is epitomized in critical Space Shuttle applications, but is increasingly being applied in CANDU plants. It includes gland design, selection and qualification of material, quality assurance, detection of defects and the effects of lubrication, surface finish, squeeze, stretch and volume constraints. In conclusion, for the severe service applications described, customized solutions have more than paid for themselves by higher reliability, lower maintenance requirements and reduced outage time. (author)

  7. Research on seal control systems for international nuclear safeguard and the vulnerability assessment on the seals

    International Nuclear Information System (INIS)

    Zhang Hongjian; Liu Tianshu; Cao Fangfang; Xu Chunyan

    2014-01-01

    Safeguard seals, also called Tamper-indicating devices (TIDs), are widely used to detect tampering or unauthorized entry in the international safeguard and security systems, Seal control systems consist of seal implementing plan, seal development and the vulnerability assessment on tbe seals, effective implementing procedures and methods of the seals. The vulnerability assessment contents of safeguard seals, thermo-shrinked film seals being as an example, and seals control systems in the implementation program are researched. The seal control systems discuss task assignment, seals management flow and seals program data flow to promote applying effectively seals. The vulnerability assessment program of seals studies assurance level to some different tampering techniques and measures. The researches must promote utilizing seals effectively for nuclear security, non-proliferation of nuclear weapons, radioactive waste management, and the nuclear material accounting and control. (authors)

  8. Miniature X-ray Tube for Electric Brachytherapy using Carbon Nanotube Field Emitter

    International Nuclear Information System (INIS)

    Heo, Sung Hwan; Kim, Hyun Jin; Ha, Jun Mok; Cho, Sung Oh

    2011-01-01

    An electric brachytherapy using a miniature x-ray tube has a major advantage to reduce the x-ray exposure of human body during the cancer radiation therapy by optimal positioning of x-ray radiation source and treatment objectives. In the view of a smaller electronic x-ray source, the CNT field emitter based xray tube can be more minimized than thermionic filament emitter based one because of a simple power supplier connection of cold field emission in diode type as well as a higher electron emission brightness of CNT. This abstract is for introducing the design of a prototype CNT field emitter based miniature x-ray tube. We have vacuum sealed CNT miniature x-ray tube with 7∼10 mm diameter, and characteristics of electron emission and x-ray transportation using MCNP5 code are surveyed

  9. Clinical evaluation of stethoscope-guided inflation of tracheal tube cuffs.

    Science.gov (United States)

    Kumar, R D C; Hirsch, N P

    2011-11-01

    Tracheal tube cuffs are commonly inflated to pressures exceeding the recommended upper limit of 30 cmH(2)O. We evaluated whether a stethoscope-guided method of cuff inflation results in pressures within the recommended range. Patients were randomly assigned to receive one of two methods of cuff inflation. In the standard 'just seal' group, air was introduced into the tracheal cuff until the audible leak at the mouth disappeared. In the stethoscope-guided group, air was introduced into the cuff until a change from harsh to soft breath sounds occurred, whilst listening with a stethoscope bell placed over the thyroid cartilage. Twenty-five patients were recruited to each group. The median (IQR [range]) cuff pressure in the 'just seal' group was 34 (28-40 [18-49]) cmH(2)O, and in the stethoscope-guided group was 20 (20-26 [16-28]) cmH(2)O, p stethoscope-guided method of tracheal tube cuff inflation is a novel, simple technique that reliably results in acceptable tracheal cuff pressures. © 2011 The Authors. Anaesthesia © 2011 The Association of Anaesthetists of Great Britain and Ireland.

  10. The IRES electronic seal

    International Nuclear Information System (INIS)

    Gourlez, P.; Funk, P.; Brochard, D.; Moreau, J.F.; Martin, J.C.

    2001-01-01

    In the framework of the French Support Program for the IAEA Safeguards, the 'Institut de Protection et de Surete Nucleaire' (IPSN), developed an electronic seal called Integrated and Reusable Electronic Seal (IRES) that enables independent verification by different inspectorates (IAEA, Euratom, and National Inspectorate) Furthermore, a bilateral co-ordination between Euratom and French domestic safeguards takes place in some French facilities regarding a common approach concerning the seals especially in case of crisis situation. The seal can be remotely interrogated by radio frequency and integrated to other Containment/surveillance systems by serial line RS 485. Data are authenticated and the IRESMAG software manages in the seal reader all functionalities of the seal and records inspection data compatible with the IAEA's Seal Database

  11. ProSeal laryngeal mask airway: An alternative to endotracheal intubation in paediatric patients for short duration surgical procedures

    Directory of Open Access Journals (Sweden)

    Jaya Lalwani

    2010-01-01

    Full Text Available The laryngeal mask airway (LMA is a supraglottic airway management device. The LMA is preferred for airway management in paediatric patients for short duration surgical procedures. The recently introduced ProSeal (PLMA, a modification of Classic LMA, has a gastric drainage tube placed lateral to main airway tube which allows the regurgitated gastric contents to bypass the glottis and prevents the pulmonary aspiration. This study was done to compare the efficacy of ProSeal LMA with an endotracheal tube in paediatric patients with respect to number of attempts for placement of devices, haemodynamic responses and perioperative respiratory complications. Sixty children, ASA I and II, weighing 10-20 kg between 2 and 8 years of age group of either sex undergoing elective ophthalmological and lower abdominal surgeries of 30-60 min duration, randomly divided into two groups of 30 patients each were studied. The number of attempts for endotracheal intubation was less than the placement of PLMA. Haemodynamic responses were significantly higher (P<0.05 after endotracheal intubation as compared to the placement of PLMA. There were no significant differences in mean SpO 2 (% and EtCO 2 levels recorded at different time intervals between the two groups. The incidence of post-operative respiratory complications cough and bronchospasm was higher after extubation than after removal of PLMA. The incidence of soft tissue trauma was noted to be higher for PLMA after its removal. There were no incidences of aspiration and hoarseness/sore throat in either group. It is concluded that ProSeal LMA can be safely considered as a suitable and effective alternative to endotracheal intubation in paediatric patients for short duration surgical procedures.

  12. Cover-gas-seal component development: dynamic inflatable-plug seal improvement

    International Nuclear Information System (INIS)

    Horton, P.H.

    1977-01-01

    This report documents the 1) radial compliance and 2) low friction coating tests conducted on the CRBRP Rotating Plug Inflatable Seals per test plan N707TR810014. Test results show that narrowing the seal blade from 0.25 to 0.12 in. will effectively reduce dynamic drag from 30 to 20 lb/ft under nominal conditions and will increase seal radial compliance from 0.12 to 0.30 in. without an unacceptable rise in dynamic drag. Tests also demonstrated that application of a teflon coating to the seal wear surface reduced breakaway drag by 25% based on results of comparison dwells

  13. Effect of bar sealing parameters on OPP/MCPP heat seal strength

    Directory of Open Access Journals (Sweden)

    2007-11-01

    Full Text Available The effect of bar sealing parameters on the heat seal strength of oriented polypropylene (OPP/metallic cast polypropylene (MCPP laminate film was investigated. Based on the results obtained from the parametric study, a bar sealing process window was developed. All points drop within the process window are combinations of platen temperature and dwell time that produce acceptable heat seal. Optimum combinations are indicated by the lower border of the window. The plateau initiation temperature, Tpi of OPP/MCPP laminate film used in the present study occurred before the final melting temperature, Tmf of the sealant material. The highest achievable heat seal strength was at the plateau region, and the corresponding failure modes were delaminating, tearing or combine failure modes (delaminating and tearing. Minimum pressure level of 1.25 bars is necessary to bring the laminate interface into intimate contact in order to effect sealing.

  14. Comparative study on two different seal surface structure for reactor pressure vessel sealing behavior

    International Nuclear Information System (INIS)

    Chen Jun; Xiong Guangming; Deng Xiaoyun

    2014-01-01

    The seal surface structure is very important to reactor pressure vessel (RPV) sealing behavior. In this paper, two 3-D RPV sealing analysis finite models have been established with different seal surface structures, in order to study the influence of two structures. The separation of RPV upper and lower flanges, bolt loads and etc. are obtained, which are used to evaluate the sealing behavior of the RPV. Meanwhile, the comparative analysis of safety margin of two seal surface structural had been done, which provides the theoretical basis for RPV seal structure design optimization. (authors)

  15. Seals in motion

    NARCIS (Netherlands)

    Brasseur, Sophie Marie Jacqueline Michelle

    2017-01-01

    The harbour seal Phoca vitulina and the grey seal Halichoerus grypus have been inhabitants of the Wadden Sea since millennia. Prehistoric findings indicate the presence of both species around 5000 BC. This changed dramatically in the mid Middle-Ages as around 1500 AC, the grey seal disappeared from

  16. Stable sonoluminescence within a water hammer tube.

    Science.gov (United States)

    Chakravarty, Avik; Georghiou, Theo; Phillipson, Tacye E; Walton, Alan J

    2004-06-01

    The sonoluminescence (SL) from the collapse of a single gas bubble within a liquid can be produced repetitively using an acoustic resonator. An alternative technique using a water hammer tube, producing SL from bubbles of greater size, is described here. A sealed vertical tube partly filled with a liquid and a gas at low pressure is subjected to vertical vibrations. The oscillation of the pressure within the liquid column, due to inertial forces, excites cavitation bubbles to grow and collapse. Rotation is used to confine the bubbles to the axis of the tube. Bright SL emissions were observed in a number of liquids. Repetitive emission was produced from bubbles in condensed phosphoric acid. Bubbles of 0.4 mm ambient radius (containing 2x 10(14) xenon atoms) were excited by vibration at 35 Hz. Approximately 10(12) photons were emitted per collapse in the range 400-700 nm (over four orders of magnitude greater than the brightest SL reported previously), corresponding to a 1% efficiency of the conversion of mechanical energy into light.

  17. The thin-wall tube drift chamber operating in vacuum (prototype)

    Science.gov (United States)

    Alexeev, G. D.; Glonti, L. N.; Kekelidze, V. D.; Malyshev, V. L.; Piskun, A. A.; Potrbenikov, Yu. K.; Rodionov, V. K.; Samsonov, V. A.; Tokmenin, V. V.; Shkarovskiy, S. N.

    2013-08-01

    The goal of this work was to design drift tubes and a chamber operating in vacuum, and to develop technologies for tubes independent assembly and mounting in the chamber. These design and technology were tested on the prototype. The main features of the chamber are the following: the drift tubes are made of flexible mylar film (wall thickness 36 μm, diameter 9.80 mm, length 2160 mm) using ultrasonic welding along the generatrix; the welding device and methods were developed at JINR. Drift tubes with end plugs, anode wires and spacers were completely assembled outside the chamber. "Self-centering" spacers and bushes were used for precise setting of the anode wires and tubes. The assembled tubes were sealed with O-rings in their seats in the chamber which simplified the chamber assembling. Moreover the tube assembly and the chamber manufacture can be performed independently and in parallel; this sufficiently reduces the total time of chamber manufacture and assembling, its cost and allows tubes to be tested outside the chamber. The technology of independent tube assembling is suitable for a chamber of any shape but a round chamber is preferable for operation in vacuum. Single channel amplifier-discriminator boards which are more stable against cross talks were used for testing the tubes. Independently assembled tubes were mounted into the chamber prototype and its performance characteristic measured under the vacuum conditions. The results showed that both the structure and the tubes themselves normally operate. They are suitable for making a full-scale drift chamber for vacuum.

  18. The thin-wall tube drift chamber operating in vacuum (prototype)

    International Nuclear Information System (INIS)

    Alexeev, G.D.; Glonti, L.N.; Kekelidze, V.D.; Malyshev, V.L.; Piskun, A.A.; Potrbenikov, Yu.K.; Rodionov, V.K.; Samsonov, V.A.; Tokmenin, V.V.; Shkarovskiy, S.N.

    2013-01-01

    The goal of this work was to design drift tubes and a chamber operating in vacuum, and to develop technologies for tubes independent assembly and mounting in the chamber. These design and technology were tested on the prototype. The main features of the chamber are the following: the drift tubes are made of flexible mylar film (wall thickness 36 μm, diameter 9.80 mm, length 2160 mm) using ultrasonic welding along the generatrix; the welding device and methods were developed at JINR. Drift tubes with end plugs, anode wires and spacers were completely assembled outside the chamber. “Self-centering” spacers and bushes were used for precise setting of the anode wires and tubes. The assembled tubes were sealed with O-rings in their seats in the chamber which simplified the chamber assembling. Moreover the tube assembly and the chamber manufacture can be performed independently and in parallel; this sufficiently reduces the total time of chamber manufacture and assembling, its cost and allows tubes to be tested outside the chamber. The technology of independent tube assembling is suitable for a chamber of any shape but a round chamber is preferable for operation in vacuum. Single channel amplifier-discriminator boards which are more stable against cross talks were used for testing the tubes. Independently assembled tubes were mounted into the chamber prototype and its performance characteristic measured under the vacuum conditions. The results showed that both the structure and the tubes themselves normally operate. They are suitable for making a full-scale drift chamber for vacuum

  19. The thin-wall tube drift chamber operating in vacuum (prototype)

    Energy Technology Data Exchange (ETDEWEB)

    Alexeev, G.D. [Joint Institute for Nuclear Research, Dubna (Russian Federation); Glonti, L.N., E-mail: glonti@sunse.jinr.ru [Joint Institute for Nuclear Research, Dubna (Russian Federation); Kekelidze, V.D.; Malyshev, V.L.; Piskun, A.A.; Potrbenikov, Yu.K.; Rodionov, V.K.; Samsonov, V.A.; Tokmenin, V.V.; Shkarovskiy, S.N. [Joint Institute for Nuclear Research, Dubna (Russian Federation)

    2013-08-01

    The goal of this work was to design drift tubes and a chamber operating in vacuum, and to develop technologies for tubes independent assembly and mounting in the chamber. These design and technology were tested on the prototype. The main features of the chamber are the following: the drift tubes are made of flexible mylar film (wall thickness 36 μm, diameter 9.80 mm, length 2160 mm) using ultrasonic welding along the generatrix; the welding device and methods were developed at JINR. Drift tubes with end plugs, anode wires and spacers were completely assembled outside the chamber. “Self-centering” spacers and bushes were used for precise setting of the anode wires and tubes. The assembled tubes were sealed with O-rings in their seats in the chamber which simplified the chamber assembling. Moreover the tube assembly and the chamber manufacture can be performed independently and in parallel; this sufficiently reduces the total time of chamber manufacture and assembling, its cost and allows tubes to be tested outside the chamber. The technology of independent tube assembling is suitable for a chamber of any shape but a round chamber is preferable for operation in vacuum. Single channel amplifier-discriminator boards which are more stable against cross talks were used for testing the tubes. Independently assembled tubes were mounted into the chamber prototype and its performance characteristic measured under the vacuum conditions. The results showed that both the structure and the tubes themselves normally operate. They are suitable for making a full-scale drift chamber for vacuum.

  20. Symptomatic zinc deficiency in experimental zinc deprivation.

    OpenAIRE

    Taylor, C M; Goode, H F; Aggett, P J; Bremner, I; Walker, B E; Kelleher, J

    1992-01-01

    An evaluation of indices of poor zinc status was undertaken in five male subjects in whom dietary zinc intake was reduced from 85 mumol d-1 in an initial phase of the study to 14 mumol d-1. One of the subjects developed features consistent with zinc deficiency after receiving the low zinc diet for 12 days. These features included retroauricular acneform macullo-papular lesions on the face, neck, and shoulders and reductions in plasma zinc, red blood cell zinc, neutrophil zinc and plasma alkal...

  1. Structural integrity testing of glass-ceramic/molybdenum vacuum tube frames

    International Nuclear Information System (INIS)

    Spears, R.K.

    1980-01-01

    In this study, vacuum tube subassemblies made of glass-ceramic insulators sealed to inner and outer molybdenum frames were loaded in compression to failure with a tensile test machine. Several factors were varied in processing these subassemblies. These factors included etching and nonetching of molybdenum piece parts, annealing and nonannealing of subassemblies, and vapor and non-vapor honing of insulators after sealing. After failure, the subassemblies were examined for fracture patterns. In most cases, fracture started at points near the lower portion of the inner sleeve-insulator interface. More load was carried by subassemblies having molybdenum piece parts that were acid etched. No difference appeared between the strength of subassemblies having annealed and nonannealed glass-ceramic insulators. Parts with vapor-honed insulators failed at substantially lower loads

  2. Cover gas seals. 11 - FFTF-LMFBR seal-test program, January-March 1974

    International Nuclear Information System (INIS)

    Kurzeka, W.; Oliva, R.; Welch, F.

    1974-01-01

    The objectives of this program are to: (1) conduct static and dynamic tests to demonstrate or determine the mechanical performance of full-size (cross section) FFTF fuel transfer machine and reactor vessel head seals intended for use in a sodium vapor - inert gas environment, (2) demonstrate that these FFTF seals or new seal configuration provide acceptable fission product and cover gas retention capabilities at LMFBR Clinch River Plant operating environmental conditions other than radiation, and (3) develop improved seals and seal technology for the LMFBR Clinch River Plant to support the national objective to reduce all atmospheric contaminations to low levels

  3. Computation of two-dimensional isothermal flow in shell-and-tube heat exchangers

    International Nuclear Information System (INIS)

    Carlucci, L.N.; Galpin, P.F.; Brown, J.D.; Frisina, V.

    1983-07-01

    A computational procedure is outlined whereby two-dimensional isothermal shell-side flow distributions can be calculated for tube bundles having arbitrary boundaries and flow blocking devices, such as sealing strips, defined in arbitrary locations. The procedure is described in some detail and several computed results are presented to illustrate the robustness and generality of the method

  4. Seals Research at AlliedSignal

    Science.gov (United States)

    Ullah, M. Rifat

    1996-01-01

    A consortium has been formed to address seal problems in the Aerospace sector of Allied Signal, Inc. The consortium is represented by makers of Propulsion Engines, Auxiliary Power Units, Gas Turbine Starters, etc. The goal is to improve Face Seal reliability, since Face Seals have become reliability drivers in many of our product lines. Several research programs are being implemented simultaneously this year. They include: Face Seal Modeling and Analysis Methodology; Oil Cooling of Seals; Seal Tracking Dynamics; Coking Formation & Prevention; and Seal Reliability Methods.

  5. Brush seal performance measurement system

    OpenAIRE

    Aksoy, Serdar; Akşit, Mahmut Faruk; Aksit, Mahmut Faruk; Duran, Ertuğrul Tolga; Duran, Ertugrul Tolga

    2009-01-01

    Brush seals are rapidly replacing conventional labyrinth seals in turbomachinery applications. Upon pressure application, seal stiffness increases drastically due to frictional bristle interlocking. Operating stiffness is critical to determine seal wear life. Typically, seal stiffness is measured by pressing a curved shoe to brush bore. The static-unpressurized measurement is extrapolated to pressurized and high speed operating conditions. This work presents a seal stiffness measurement syste...

  6. Seals

    International Nuclear Information System (INIS)

    Welsher, R.A.G.

    1982-01-01

    An aperture through a biological shield is sealed by a flexible sheath having a beading at one end located on an annular member slidable in the aperture such that the beading bears in sealing engagement against the sides of the aperture. The annular member is retained by a retractable latch and can be rejected by pushing it out of the aperture using a replacement annular member with a replacement sheath thereon to butt against the annular member to be rejected. The replacement annular member may be mounted on a tubular device having an outer co-axial member for operating the latch when the replacement annular member butts against the annular member to be rejected. Applications include effecting a seal between a remote handling equipment and a wall through which the equipment extends. (author)

  7. Formation of polycrystalline MgB2 synthesized by powder in sealed tube method with different initial boron phase

    Science.gov (United States)

    Yudanto, Sigit Dwi; Imaduddin, Agung; Kurniawan, Budhy; Manaf, Azwar

    2018-04-01

    Magnesium diboride, MgB2 is a new high critical temperature superconductor that discovered in the beginning of the 21st century. The MgB2 has a simple crystal structure and a high critical temperature, which can be manufactured in several forms like thin films, tapes, wires including bulk in the large scale. For that reason, the MgB2 has good prospects for various applications in the field of electronic devices. In the current work, we have explored the synthesis of MgB2 polycrystalline using powder in a sealed tube method. Different initial boron phase for the synthesized of MgB2 polycrystalline were used. These were, in addition to magnesium powders, crystalline boron, amorphous boron and combination both of them were respectively fitted in the synthesis. The raw materials were mixed in a stoichiometric ratio of Mg: B=1:2, ground using agate mortar, packed into stainless steel SS304. The pack was then sintered at temperature of 800°C for 2 hours in air atmosphere. Phase formation of MgB2 polycrystalline in difference of initial boron phase was characterized using XRD and SEM. Referring to the diffraction pattern and microstructure observation, MgB2 polycrystalline was formed, and the formation was effective when using the crystalline Mg and fully amorphous B as the raw materials. The critical temperature of the specimen was evaluated by the cryogenic magnet. The transition temperature of the MgB2 specimen synthesized using crystalline magnesium and full amorphous boron is 42.678 K (ΔTc = 0.877 K).

  8. Electronic seal

    International Nuclear Information System (INIS)

    Musyck, E.

    1981-01-01

    An electronic seal is presented for a volume such as container for fissile materials. The seal encloses a lock for barring the space as well as a device for the detection and the recording of the intervention of the lock. (AF)

  9. Evaluation of performance of Streamlined Liner of the Pharynx Airway™, Laryngeal Mask Airway-ProSeal and endotracheal tube in prone position: A prospective, randomised study

    Directory of Open Access Journals (Sweden)

    Harihar Vishwanath Hegde

    2018-01-01

    Full Text Available Background and Aims: Airway used in prone position should be efficacious and safe. The Streamlined Liner of the Pharynx Airway (SLIPA™ and Laryngeal Mask Airway-ProSeal (PLMA provide better airway seal and protection against aspiration. We planned to evaluate the performance of SLIPA™, PLMA and endotracheal tube (ETT in prone position. Methods: 114 adult patients undergoing elective surgery in prone position under general anaesthesia were randomised into Group-T (ETT, Group-S (SLIPA™ and Group-P (PLMA. Airways were inserted in supine position and patients turned prone subsequently. Airway characteristics, ventilatory parameters and complications were noted. One-way analysis of variance, Mann–Whitney U-test and Chi-square or Fisher's exact test were used. Results: Tidal volumes, peak airway pressure and compliance were comparable at all times. Leak pressure was significantly higher (P < 0.001 in Group-T (mean leak pressure = 40 cmH2O when compared to Group-S and Group-P at all the times of recording, and there was no significant difference between Group-S and Group-P. The number of patients requiring airway/neck manipulation in prone position was significantly higher (P < 0.001 in Group-S (19 [55.9%] when the three groups were compared (none in Group-T and in comparison with Group-P (5 [14.7%], P < 0.001. On airway removal, the incidence of complications and airway reaction was significantly higher in Group-T. Group-S had a significantly higher incidence of dysphagia at 2 h postoperatively. Conclusion: ETT was most efficacious. SLIPA™ and PLMA were efficacious, safe and less stimulating to the airway during removal. More patients required SLIPA™ airway/neck manipulation.

  10. Prediction of loop seal formation and clearing during small break loss of coolant accident

    International Nuclear Information System (INIS)

    Lee, Suk Ho; Kim, Hho Jung

    1992-01-01

    Behavior of loop seal formation and clearing during small break loss of coolant accident is investigated using the RELAP5/MOD2 and /MOD3 codes with the test of SB-CL-18 of the LSTF(Large Scale Test Facility). The present study examines the thermal-hydraulic mechanisms responsible for early core uncovery includeing the manometric effect due to an asymmetric coolant holdup in the steam generator upflow and downflow side. The analysis with the RELAP5/ MOD2 demonstrates the main phenomena occuring in the depressurization transient including the loop seal formation and clearing with sufficient accuracy. Nevertheless, several differences regarding the evolution of phenomena and their timing have been pointed out in the base calculations. The RELAP5/MOD3 predicts overall phenomena, particularly the steam generator liquid holdup better than the RELAP5/MOD2. The nodalization study in the components of the steam generator U-tubes and the cross-over legs with the RELAP5/MOD3 results in good prediction of the loop seal clearing phenomena and their timing. (Author)

  11. Zinc

    Science.gov (United States)

    ... Consumer Datos en español Health Professional Other Resources Zinc Fact Sheet for Consumers Have a question? Ask ... find out more about zinc? Disclaimer What is zinc and what does it do? Zinc is a ...

  12. Toxic effects of various pollutants in 11B7501 lymphoma B cell line from harbour seal (Phoca vitulina)

    International Nuclear Information System (INIS)

    Frouin, Heloise; Fortier, Marlene; Fournier, Michel

    2010-01-01

    Although, heavy metals and polycyclic aromatic hydrocarbons (PAHs) have been reported at high levels in marine mammals, little is known about the toxic effects of some of these contaminants. In this study, we assessed the immunotoxic and genotoxic effects of seven heavy metals (arsenic, vanadium, selenium, iron, zinc, silver and chromium) and one PAH (benzo[a]pyrene or B[a]P) on a lymphoma B cell line from harbour seal (Phoca vitulina). A significant reduction in lymphocyte proliferation was registered following an exposure to 0.05 μM of B[a]P, 5 μM of arsenic or selenium, 50 μM of vanadium, 100 μM of silver and 200 μM of iron. On the contrary, zinc increased the lymphoproliferative response at 200 μM. Decreased phagocytosis was observed at 20 μM of arsenic, 50 μM of B[a]P or selenium, 200 μM of zinc and 500 μM of vanadium. Micronuclei induction occurred with 0.2 μM of B[a]P, 100 μM of vanadium and with 200 μM of arsenic or selenium. Exposure to 50 μM of arsenic decreased G 2 /M phase of the cell cycle. Chromium did not induce any effects at the concentrations tested. Concentrations of heavy metals (except silver and vanadium) and B[a]P inducing an toxic effect are within the environmental ranges reported in the blood tissue of pinnipeds. The reduction of some functional activities of the harbour seal immune system may cause a significant weakness capable of altering host resistance to disease in free-ranging pinnipeds.

  13. Externally mounted radioactivity detector for MWD employing radial inline scintillator and photomultiplier tube

    International Nuclear Information System (INIS)

    Meisner, J.E.; Mumby, E.S.; Groeschel, V.E.

    1991-01-01

    Improved radioactivity well logging may be achieved by mounting a scintillator and photomultiplier tube in a single case interfacing with a hole extending through a drill collar at the lower end of a drill string so that measurements can be made while drilling. Radioactive sources (when required for well logging) are mounted in cavities which open to the exterior of the drill collar. Light from the scintillator is coupled directly to the aligned photomultiplier tube both of which are mounted in a case extending radially within the drill collar and sealingly engaging an electronics housing within the drill collar and the drill collar wall surrounding the hole. The scintillator is of greater diameter than the photomultiplier tube. A frustoconical light pipe connects the scintillator and the photomultiplier tube, channeling scintillation in the crystal to the photomultiplier to provide an amplified detection capability over that for a scintillator having the same diameter as the photomultiplier tube. (author)

  14. A hybrid floating brush seal (HFBS) for improved sealing and wear performance in turbomachinery applications

    Science.gov (United States)

    Lattime, Scott Byran

    A conceptually new type of seal has been developed for gas turbine applications which dramatically reduces wear and leakage associated with current labyrinth and brush seal technologies. The Hybrid Floating Brush Seal (HFBS) combines brush seal and film riding face seal technologies to create a hybrid seal that allows both axial and radial excursions of the sealed shaft, while simultaneously eliminating interface surface speeds (friction and heat) between the rotor and the brush material that characterize standard brush seal technology. A simple test rig was designed to evaluate feasibility of the HFBS under relatively low pressures and rotational speeds (50psig, 5krpm). A second test stand was created to study the effects of centrifugal force on bristle deflection. A third test facility was constructed for prototype development and extensive room temperature testing at moderate pressures and fairly high rotational speeds (100psig, 40krpm). This test rig also allowed the evaluation of the HFBS during axial movement of a rotating shaft. An analytical model to predict the effects of centrifugal force on the bristles of a rotating brush seal was developed. Room temperature analysis of the HFBS proved successful for relatively high operating rotational velocities at moderate pressures with very acceptable leakage rates for gas turbine engines. Brush seals were able to track rotor speeds up to 24krpm while maintaining sealing integrity. The HFBS's ability to function under axial shaft displacement and synchronous dynamic radial loading was also proven successful. Hydrodynamic performance of the face seal was proven to provide adequate stiffness and load carrying capacity to keep the brush seal from contacting the face seal at pressure drops across the brush of up to 100psi. Leakage performance over standard brush seal and labyrinth technology was quite dramatic. The HFBS showed its sealing advantage using much higher radial interference between the rotor and the bristle

  15. X-ray tube incorporating a rotating anode with magnetic bearings

    International Nuclear Information System (INIS)

    1979-01-01

    This patent describes an X-ray tube incorporating a rotating anode. The rotor consists of a single, soft-magnetic dish which is fixed on the axis and which seals the magnetic yoke of the stator. Looking in the direction of the axis, one side is equipped with two circular pole surfaces, one at least of which is provided with circular pole-shoes, separated from one another by concentric grooves. (T.P.)

  16. Hydrodynamic perception in true seals (Phocidae) and eared seals (Otariidae).

    Science.gov (United States)

    Hanke, Wolf; Wieskotten, Sven; Marshall, Christopher; Dehnhardt, Guido

    2013-06-01

    Pinnipeds, that is true seals (Phocidae), eared seals (Otariidae), and walruses (Odobenidae), possess highly developed vibrissal systems for mechanoreception. They can use their vibrissae to detect and discriminate objects by direct touch. At least in Phocidae and Otariidae, the vibrissae can also be used to detect and analyse water movements. Here, we review what is known about this ability, known as hydrodynamic perception, in pinnipeds. Hydrodynamic perception in pinnipeds developed convergently to the hydrodynamic perception with the lateral line system in fish and the sensory hairs in crustaceans. So far two species of pinnipeds, the harbour seal (Phoca vitulina) representing the Phocidae and the California sea lion (Zalophus californianus) representing the Otariidae, have been studied for their ability to detect local water movements (dipole stimuli) and to follow hydrodynamic trails, that is the water movements left behind by objects that have passed by at an earlier point in time. Both species are highly sensitive to dipole stimuli and can follow hydrodynamic trails accurately. In the individuals tested, California sea lions were clearly more sensitive to dipole stimuli than harbour seals, and harbour seals showed a superior trail following ability as compared to California sea lions. Harbour seals have also been shown to derive additional information from hydrodynamic trails, such as motion direction, size and shape of the object that caused the trail (California sea lions have not yet been tested). The peculiar undulated shape of the harbour seals' vibrissae appears to play a crucial role in trail following, as it suppresses self-generated noise while the animal is swimming.

  17. Structural and Shielding Safety of a Transport Package for Radioisotope Sealed Source Assembly

    Energy Technology Data Exchange (ETDEWEB)

    Seo, Kiseog; Cho, Ilje; Kim, Donghak [Korea Atomic Energy Research Institute, Taejon (Korea, Republic of)

    2006-07-01

    As some kinds of radioisotope (RI) sealed source are produced by HANARO research reactor, a demand of RI transport package is increasing gradually. Foreign countries, which produce the various RIs, have the intrinsic model of the RI transport package. It is necessary to develop a RI and its transport package simultaneously. It is difficult to design a shielding part for this transport package because the passage for this source assembly should be provided from the center of shielding part to the outside of the package. In order to endure the accident conditions such as a 9 m drop and puncture, this transport package consists of the guide tubes, a gamma shield and a shock absorber. This paper describe that a shielding and structural safety of RI sealed source transport package are evaluated under the accident conditions.

  18. Structural and Shielding Safety of a Transport Package for Radioisotope Sealed Source Assembly

    International Nuclear Information System (INIS)

    Seo, Kiseog; Cho, Ilje; Kim, Donghak

    2006-01-01

    As some kinds of radioisotope (RI) sealed source are produced by HANARO research reactor, a demand of RI transport package is increasing gradually. Foreign countries, which produce the various RIs, have the intrinsic model of the RI transport package. It is necessary to develop a RI and its transport package simultaneously. It is difficult to design a shielding part for this transport package because the passage for this source assembly should be provided from the center of shielding part to the outside of the package. In order to endure the accident conditions such as a 9 m drop and puncture, this transport package consists of the guide tubes, a gamma shield and a shock absorber. This paper describe that a shielding and structural safety of RI sealed source transport package are evaluated under the accident conditions

  19. Shaft seal assembly and method

    Science.gov (United States)

    Keba, John E. (Inventor)

    2007-01-01

    A pressure-actuated shaft seal assembly and associated method for controlling the flow of fluid adjacent a rotatable shaft are provided. The seal assembly includes one or more seal members that can be adjusted between open and closed positions, for example, according to the rotational speed of the shaft. For example, the seal member can be configured to be adjusted according to a radial pressure differential in a fluid that varies with the rotational speed of the shaft. In addition, in the closed position, each seal member can contact a rotatable member connected to the shaft to form a seal with the rotatable member and prevent fluid from flowing through the assembly. Thus, the seal can be closed at low speeds of operation and opened at high speeds of operation, thereby reducing the heat and wear in the seal assembly while maintaining a sufficient seal during all speeds of operation.

  20. Oceanic corrosion test of bare and zinc-protected aluminum alloys for seawater heat exchangers

    Science.gov (United States)

    Sasscer, D. S.; Morgan, T. O.; Rivera, C.; Ernst, R.; Scott, A. C.; Summerson, T. J.

    1982-01-01

    Bare 3004 tubes, 7072 Alclad 3004 tubes, and bare and zinc diffusion treated 3003 extrusions from a brazed aluminum, plate-fin heat exchanger were exposed to 1.8 m/sec flowing seawater aboard an open ocean test facility moored 3.4 km off the southeast coast of Puerto Rico. After six months exposure, the average corrosion rates for most varieties of aluminum materials converged to a low value of 0.015 mm/yr (0.6 mils/yr). Pitting did not occur in bare 3003 and 3004 samples during the six month test. Pitting did occur to varying degrees in the Alclad and zinc diffusion treated material, but did not penetrate to the base metal. Biofouling countermeasures (intermittent chlorination and brushing) did not affect the corrosion rates to any significant extent. Intermittent chlorination at a level of 0.5 ppm for 28 minutes daily controlled microbiofouling of the samples but did not prevent the development of a macrobiofouling community in areas of the plumbing with low flow.

  1. Fracture of longitudinally cracked ductile tubes

    International Nuclear Information System (INIS)

    Larsson, H.; Bernard, J.

    1978-01-01

    Various bulging factor and plasticity correction factor formulations are discussed and a new plasticity correction factor leading to a simple failure law is proposed. Failure stresses predicted by the usual Linear Elastic Fracture Mechanics formula corrected for plasticity are shown to be identical with the Dowling and Townley two-criteria approach if the relevant parameters are chosen in a suitable manner. Burst tests on AISI 304 stainless steel tubes performed at the Joint Research Centre, Ispra are described. The strengthening effect of the sealing patch was taken into account by replacing the Folias bulging factor by a smaller empirical factor determined by Bernard and Henry from fatigue crack growth tests. A flow stress sigma and a toughness Ksub(c) were derived which apply to the prediction of the onset of stable crack growth in 304 stainless steel tubes at room temperature. For other ductile materials and temperatures tentative formulae are proposed. (author)

  2. Rotary shaft seal

    International Nuclear Information System (INIS)

    Langebrake, C.O.

    1984-01-01

    The invention is a novel rotary shaft seal assembly which provides positive-contact sealing when the shaft is not rotated and which operates with its sealing surfaces separated by a film of compressed ambient gas whose width is independent of the speed of shaft rotation. In a preferred embodiment, the assembly includes a disc affixed to the shaft for rotation therewith. Axially movable, non-rotatable plates respectively supported by sealing bellows are positioned on either side of the disc to be in sealing engagement therewith. Each plate carries piezoelectric transducer elements which are electrically energized at startup to produce films of compressed ambient gas between the confronting surfaces of the plates and the disc. Following shutdown of the shaft, the transducer elements are de-energized. A control circuit responds to incipient rubbing between the plate and either disc by altering the electrical input to the transducer elements to eliminate rubbing

  3. Seal containment system

    International Nuclear Information System (INIS)

    Kugler, R.W.; Gerkey, K.S.; Kasner, W.H.

    1978-01-01

    An automated system for transporting nuclear fuel elements between fuel element assembly stations without contaminating the area outside the sealed assembly stations is described. The system comprises a plurality of assembly stations connected together by an elongated horizontal sealing mechanism and an automatic transport mechanism for transporting a nuclear fuel element in a horizontal attitude between the assembly stations while the open end of the fuel element extends through the sealing mechanism into the assembly station enclosure. The sealing mechanism allows the fuel element to be advanced by the transport mechanism while limiting the escape of radioactive particles from within the assembly station enclosure. 4 claims, 6 figures

  4. A reconfigurable image tube using an external electronic image readout

    Science.gov (United States)

    Lapington, J. S.; Howorth, J. R.; Milnes, J. S.

    2005-08-01

    We have designed and built a sealed tube microchannel plate (MCP) intensifier for optical/NUV photon counting applications suitable for 18, 25 and 40 mm diameter formats. The intensifier uses an electronic image readout to provide direct conversion of event position into electronic signals, without the drawbacks associated with phosphor screens and subsequent optical detection. The Image Charge technique is used to remove the readout from the intensifier vacuum enclosure, obviating the requirement for additional electrical vacuum feedthroughs and for the readout pattern to be UHV compatible. The charge signal from an MCP intensifier is capacitively coupled via a thin dielectric vacuum window to the electronic image readout, which is external to the sealed intensifier tube. The readout pattern is a separate item held in proximity to the dielectric window and can be easily detached, making the system easily reconfigurable. Since the readout pattern detects induced charge and is external to the tube, it can be constructed as a multilayer, eliminating the requirement for narrow insulator gaps and allowing it to be constructed using standard PCB manufacturing tolerances. We describe two readout patterns, the tetra wedge anode (TWA), an optimized 4 electrode device similar to the wedge and strip anode (WSA) but with a factor 2 improvement in resolution, and an 8 channel high speed 50 ohm device, both manufactured as multilayer PCBs. We present results of the detector imaging performance, image resolution, linearity and stability, and discuss the development of an integrated readout and electronics device based on these designs.

  5. Core disruptive accident margin seal

    International Nuclear Information System (INIS)

    Golden, M.P.

    1979-01-01

    An apparatus for sealing the annulus defined within a substantially cylindrical rotatable riser assembly and plug combination of a nuclear reactor closure head is described. The apparatus comprises an inflatable sealing mechanism disposed in one portion of the riser assembly near the annulus such that upon inflation the sealing mechanism is radially actuated against the other portion of the riser assembly thereby sealing the annulus. The apparatus further comprises a connecting mechanism which places one end of the sealing mechanism in fluid communication with the reactor cover gas so that overpressurization of the reactor cover gas will increase the radial actuation of the sealing mechanism thus enhancing sealing of the annulus

  6. Improved circumferential shaft seal

    Science.gov (United States)

    Ludwig, L. P.; Strom, T. N.

    1974-01-01

    Comparative tests of modified and unmodified carbon ring seals showed that addition of helical grooves to conventional segmented carbon ring seals reduced leakage significantly. Modified seal was insensitive to shaft runout and to flooding by lubricant.

  7. Seals for sealing a pressure vessel such as a nuclear reactor vessel or the like

    International Nuclear Information System (INIS)

    Bruns, H.J.; Huelsermann, K.H.

    1975-01-01

    A description is given of seals for sealing a pressure vessel such as a nuclear reactor vessel, steam boiler vessel, or any other vessel which is desirably sealed against pressure of the type including a housing and a housing closure that present opposed vertical sealing surfaces which define the sides of a channel. The seals of the present invention comprise at least one sealing member disposed in the channel, having at least one stop face, a base portion and two shank portions extending from the base portion to form a groove-like recess. The shank portions are provided with sealing surfaces arranged to mate with the opposed vertical pressure vessel sealing surfaces. A shank-spreading wedge element also disposed in the channel has at least one stop face and is engaged in the groove-like recess with the sealing member and wedge element stop face adjacent to each other

  8. Recovery of yttrium from fluorescent powder of cathode ray tube, CRT: Zn removal by sulphide precipitation

    International Nuclear Information System (INIS)

    Innocenzi, Valentina; De Michelis, Ida; Ferella, Francesco; Beolchini, Francesca; Kopacek, Bernd; Vegliò, Francesco

    2013-01-01

    Highlights: • Treatment of fluorescent powder of CRT waste. • Factorial experimental designs to study acid leaching of fluorescent powder and the purification of leach liquors. • Recover of yttrium by precipitation using oxalic acid. • Suitable flowsheet to recover yttrium from fluorescent powder. - Abstract: This work is focused on the recovery of yttrium and zinc from fluorescent powder of cathode ray tube (CRT). Metals are extracted by sulphuric acid in the presence of hydrogen peroxide. Leaching tests are carried out according to a 2 2 full factorial plan and the highest extraction yields for yttrium and zinc equal to 100% are observed under the following conditions: 3 M of sulphuric acid, 10% v/v of H 2 O 2 concentrated solution at 30% v/v, 10% w/w pulp density, 70 °C and 3 h of reaction. Two series of precipitation tests for zinc are carried out: a 2 2 full factorial design and a completely randomized factorial design. In these series the factors investigated are pH of solution during the precipitation and the amount of sodium sulphide added to precipitate zinc sulphide. The data of these tests are used to describe two empirical mathematical models for zinc and yttrium precipitation yields by regression analysis. The highest precipitation yields for zinc are obtained under the following conditions: pH equal to 2–2.5% and 10–12% v/v of Na 2 S concentrated solution at 10% w/v. In these conditions the coprecipitation of yttrium is of 15–20%. Finally further yttrium precipitation experiments by oxalic acid on the residual solutions, after removing of zinc, show that yttrium could be recovered and calcined to obtain the final product as yttrium oxide. The achieved results allow to propose a CRT recycling process based on leaching of fluorescent powder from cathode ray tube and recovery of yttrium oxide after removing of zinc by precipitation. The final recovery of yttrium is 75–80%

  9. Recovery of yttrium from fluorescent powder of cathode ray tube, CRT: Zn removal by sulphide precipitation

    Energy Technology Data Exchange (ETDEWEB)

    Innocenzi, Valentina, E-mail: valentina.innocenzi1@univaq.it [Department of Industrial Engineering and Information and Economy, University of L’Aquila, Via Giovanni Gronchi n.18, Nucleo Ind.le di Pile, 67100 L’Aquila (Italy); De Michelis, Ida; Ferella, Francesco [Department of Industrial Engineering and Information and Economy, University of L’Aquila, Via Giovanni Gronchi n.18, Nucleo Ind.le di Pile, 67100 L’Aquila (Italy); Beolchini, Francesca [Department of Marine Sciences, Polytechnic Institute of Marche, Via Brecce Bianche, 60131 Ancona (Italy); Kopacek, Bernd [SAT, Austrian Society for Systems Engineering and Automation, Gurkasse 43/2, A-1140 Vienna (Austria); Vegliò, Francesco [Department of Industrial Engineering and Information and Economy, University of L’Aquila, Via Giovanni Gronchi n.18, Nucleo Ind.le di Pile, 67100 L’Aquila (Italy)

    2013-11-15

    Highlights: • Treatment of fluorescent powder of CRT waste. • Factorial experimental designs to study acid leaching of fluorescent powder and the purification of leach liquors. • Recover of yttrium by precipitation using oxalic acid. • Suitable flowsheet to recover yttrium from fluorescent powder. - Abstract: This work is focused on the recovery of yttrium and zinc from fluorescent powder of cathode ray tube (CRT). Metals are extracted by sulphuric acid in the presence of hydrogen peroxide. Leaching tests are carried out according to a 2{sup 2} full factorial plan and the highest extraction yields for yttrium and zinc equal to 100% are observed under the following conditions: 3 M of sulphuric acid, 10% v/v of H{sub 2}O{sub 2} concentrated solution at 30% v/v, 10% w/w pulp density, 70 °C and 3 h of reaction. Two series of precipitation tests for zinc are carried out: a 2{sup 2} full factorial design and a completely randomized factorial design. In these series the factors investigated are pH of solution during the precipitation and the amount of sodium sulphide added to precipitate zinc sulphide. The data of these tests are used to describe two empirical mathematical models for zinc and yttrium precipitation yields by regression analysis. The highest precipitation yields for zinc are obtained under the following conditions: pH equal to 2–2.5% and 10–12% v/v of Na{sub 2}S concentrated solution at 10% w/v. In these conditions the coprecipitation of yttrium is of 15–20%. Finally further yttrium precipitation experiments by oxalic acid on the residual solutions, after removing of zinc, show that yttrium could be recovered and calcined to obtain the final product as yttrium oxide. The achieved results allow to propose a CRT recycling process based on leaching of fluorescent powder from cathode ray tube and recovery of yttrium oxide after removing of zinc by precipitation. The final recovery of yttrium is 75–80%.

  10. Seals in nuclear reactors

    International Nuclear Information System (INIS)

    1979-01-01

    The seals described are for use in a nuclear reactor where there are fuel assemblies in a vessel, an inlet and an outlet for circulating a coolant in heat transfer relationship with the fuel assemblies and a closure head on the vessel in a tight fluid relationship. The closure head comprises rotatable plugs which have mechanical seals disposed in the annulus around each plug while allowing free rotation of the plug when the seal is not actuated. The seal is usually an elastomer or copper. A means of actuating the seal is attached for drawing it vertically into the annulus for sealing. When the reactor coolant is liquid sodium, contact with oxygen must be avoided and argon cover gas fills the space between the bottom of the closure head and the coolant liquid level and the annuli in the closure head. (U.K.)

  11. Investigation of positive shaft seals

    Science.gov (United States)

    Pfouts, J. O.

    1970-01-01

    Welded metal bellows secondary seals prevent secondary seal leakage with a minimum number of potential leak paths. High performance seal is obtained by controlling the potentially unstable seal-face movements induced by mechanical vibrations and fluid pressure pulsations.

  12. Continuous improvement of pump seals

    International Nuclear Information System (INIS)

    Wong, W.; Eyvindson, A.; Rhodes, D.B.

    2003-01-01

    Pump seal reliability continues to be an area needing improvement and ongoing vigilance. Methods have been developed for identifying and assessing factors relating to seal performance, selecting the most relevant ones for a specific station, and then focusing on the most significant aspects and how to improve. Discussion invariably addresses maintenance practices, seal design, monitoring capabilities, operating conditions, transients, and pump and motor design. Success in reliability improvement requires ongoing dialogue among the station operators, pump manufacturers and seal designers. AECL CAN-seals lead the nuclear industry in reliability and seal life. They effectively save operators millions of dollars in outage time and person-rem. This paper describes some of the significant developments in AECL's ongoing program in seal R and D, as well as recent new installations following the most demanding seal qualification programs to date. (author)

  13. Zinc corrosion after loss-of-coolant accidents in pressurized water reactors – Physicochemical effects

    Energy Technology Data Exchange (ETDEWEB)

    Kryk, Holger, E-mail: h.kryk@hzdr.de [Helmholtz-Zentrum Dresden-Rossendorf, Institute of Fluid Dynamics, P.O. Box 510119, D-01314 Dresden (Germany); Hoffmann, Wolfgang [Helmholtz-Zentrum Dresden-Rossendorf, Institute of Fluid Dynamics, P.O. Box 510119, D-01314 Dresden (Germany); Kästner, Wolfgang; Alt, Sören; Seeliger, André; Renger, Stefan [Hochschule Zittau/Görlitz, Institute of Process Technology, Process Automation and Measuring Technology, Theodor-Körner-Allee 16, D-02763 Zittau (Germany)

    2014-12-15

    Highlights: • Physicochemical effects due to post-LOCA zinc corrosion in PWR were elucidated. • Decreasing solubility of corrosion products with increasing temperature was found. • Solid corrosion products may be deposited on hot surfaces and/or within hot-spots. • Corrosion products precipitating from coolant were identified as zinc borates. • Depending on coolant temperature, different types of zinc borate are formed. - Abstract: Within the framework of the reactor safety research, generic experimental investigations were carried out aiming at the physicochemical background of possible zinc corrosion product formation, which may occur inside the reactor pressure vessel during the sump circulation operation after loss-of-coolant accidents in pressurized water reactors. The contact of the boric acid containing coolant with hot-dip galvanized steel containment internals causes corrosion of the corresponding materials resulting in dissolution of the zinc coat. A retrograde solubility of zinc corrosion products with increasing temperature was observed during batch experiments of zinc corrosion in boric acid containing coolants. Thus, the formation and deposition of solid corrosion products cannot be ruled out if the coolant containing dissolved zinc is heated up during its recirculation into hot regions within the emergency cooling circuit (e.g. hot-spots in the core). Corrosion experiments at a lab-scale test facility, which included formation of corrosion products at a single heated cladding tube, proved that dissolved zinc, formed at low temperatures in boric acid solution by zinc corrosion, turns into solid deposits of zinc borates when contacting heated zircaloy surfaces during the heating of the coolant. Moreover, the temperature of formation influences the chemical composition of the zinc borates and thus the deposition and mobilization behavior of the products.

  14. Zinc corrosion after loss-of-coolant accidents in pressurized water reactors – Physicochemical effects

    International Nuclear Information System (INIS)

    Kryk, Holger; Hoffmann, Wolfgang; Kästner, Wolfgang; Alt, Sören; Seeliger, André; Renger, Stefan

    2014-01-01

    Highlights: • Physicochemical effects due to post-LOCA zinc corrosion in PWR were elucidated. • Decreasing solubility of corrosion products with increasing temperature was found. • Solid corrosion products may be deposited on hot surfaces and/or within hot-spots. • Corrosion products precipitating from coolant were identified as zinc borates. • Depending on coolant temperature, different types of zinc borate are formed. - Abstract: Within the framework of the reactor safety research, generic experimental investigations were carried out aiming at the physicochemical background of possible zinc corrosion product formation, which may occur inside the reactor pressure vessel during the sump circulation operation after loss-of-coolant accidents in pressurized water reactors. The contact of the boric acid containing coolant with hot-dip galvanized steel containment internals causes corrosion of the corresponding materials resulting in dissolution of the zinc coat. A retrograde solubility of zinc corrosion products with increasing temperature was observed during batch experiments of zinc corrosion in boric acid containing coolants. Thus, the formation and deposition of solid corrosion products cannot be ruled out if the coolant containing dissolved zinc is heated up during its recirculation into hot regions within the emergency cooling circuit (e.g. hot-spots in the core). Corrosion experiments at a lab-scale test facility, which included formation of corrosion products at a single heated cladding tube, proved that dissolved zinc, formed at low temperatures in boric acid solution by zinc corrosion, turns into solid deposits of zinc borates when contacting heated zircaloy surfaces during the heating of the coolant. Moreover, the temperature of formation influences the chemical composition of the zinc borates and thus the deposition and mobilization behavior of the products

  15. A magnetic fluid seal for rotary blood pumps: effects of seal structure on long-term performance in liquid.

    Science.gov (United States)

    Mitamura, Yoshinori; Takahashi, Sayaka; Amari, Shuichi; Okamoto, Eiji; Murabayashi, Shun; Nishimura, Ikuya

    2011-03-01

    A magnetic fluid (MF) seal enables mechanical contact-free rotation of the shaft and hence has excellent durability. The performance of an MF seal, however, has been reported to decrease in liquids. We developed an MF seal that has a "shield" mechanism, and a new MF with a higher magnetization of 47.9 kA/m. The sealing performance of the MF seal installed in a rotary blood pump was studied. Three types of MF seals were used. Seal A was a conventional seal without a shield. Seal B had the same structure as that of Seal A, but the seal was installed at 1 mm below liquid level. Seal C was a seal with a shield and the MF was set at 1 mm below liquid level. Seal A failed after 6 and 11 days. Seal B showed better results (20 and 73 days). Seal C showed long-term durability (217 and 275 days). The reason for different results in different seal structures was considered to be different flow conditions near the magnetic fluid. Fluid dynamics near the MF in the pump were analyzed using computational fluid dynamics (CFD) software. We have developed an MF seal with a shield that works in liquid for >275 days. The MF seal is promising as a shaft seal for rotary blood pumps.

  16. Borehole sealing method and apparatus

    International Nuclear Information System (INIS)

    Hartley, J.N.; Jansen, G. Jr.

    1977-01-01

    A method and apparatus is described for sealing boreholes in the earth. The borehole is blocked at the sealing level, and a sealing apparatus capable of melting rock and earth is positioned in the borehole just above seal level. The apparatus is heated to rock-melting temperature and powdered rock or other sealing material is transported down the borehole to the apparatus where it is melted, pooling on the mechanical block and allowed to cool and solidify, sealing the hole. Any length of the borehole can be sealed by slowly raising the apparatus in the borehole while continuously supplying powdered rock to the apparatus to be melted and added to the top of the column of molten and cooling rock, forming a continuous borehole seal. The sealing apparatus consists of a heater capable of melting rock, including means for supplying power to the heater, means for transporting powdered rock down the borehole to the heater, means for cooling the apparatus and means for positioning the apparatus in the borehole. 5 claims, 1 figure

  17. Dietary phytate, zinc and hidden zinc deficiency.

    Science.gov (United States)

    Sandstead, Harold H; Freeland-Graves, Jeanne H

    2014-10-01

    Epidemiological data suggest at least one in five humans are at risk of zinc deficiency. This is in large part because the phytate in cereals and legumes has not been removed during food preparation. Phytate, a potent indigestible ligand for zinc prevents it's absorption. Without knowledge of the frequency of consumption of foods rich in phytate, and foods rich in bioavailable zinc, the recognition of zinc deficiency early in the illness may be difficult. Plasma zinc is insensitive to early zinc deficiency. Serum ferritin concentration≤20μg/L is a potential indirect biomarker. Early effects of zinc deficiency are chemical, functional and may be "hidden". The clinical problem is illustrated by 2 studies that involved US Mexican-American children, and US premenopausal women. The children were consuming home diets that included traditional foods high in phytate. The premenopausal women were not eating red meat on a regular basis, and their consumption of phytate was mainly from bran breakfast cereals. In both studies the presence of zinc deficiency was proven by functional responses to controlled zinc treatment. In the children lean-mass, reasoning, and immunity were significantly affected. In the women memory, reasoning, and eye-hand coordination were significantly affected. A screening self-administered food frequency questionnaire for office might help caregiver's identify patients at risk of zinc deficiency. Copyright © 2014 Elsevier GmbH. All rights reserved.

  18. TECHNOLOGY ROADMAPPING FOR IAEA SEALS.

    Energy Technology Data Exchange (ETDEWEB)

    HOFFHEINS,B.; ANNESE,C.; GOODMAN,M.; OCONNOR,W.; GUSHUE,S.; PEPPER,S.

    2003-07-13

    In the fall of 2002, the U.S. Support Program (USSP) initiated an effort to define a strategy or ''roadmap'' for future seals technologies and to develop a generalized process for planning safeguards equipment development, which includes seals and other safeguards equipment. The underlying objectives of the USSP include becoming more proactive than reactive in addressing safeguards equipment needs, helping the IAEA to maintain an inventory of cost-effective, reliable, and effective safeguards equipment, establishing a long-term planning horizon, and securing IAEA ownership in the process of effective requirements definition and timely transitioning of new or improved systems for IAEA use. At an initial workshop, seals, their functions, performance issues, and future embodiments were discussed in the following order: adhesive seals, metal seals, passive and active loop seals, ultrasonic seals, tamper indicating enclosures (including sample containers, equipment enclosures, and conduits). Suggested improvements to these technologies focused largely on a few themes: (1) The seals must be applied quickly, easily, and correctly; (2) Seals and their associated equipment should not unduly add bulk or weight to the inspectors load; (3) Rapid, in-situ verifiability of seals is desirable; and (4) Seal systems for high risk or high value applications should have two-way, remote communications. Based upon these observations and other insights, the participants constructed a skeletal approach for seals technology planning. The process begins with a top-level review of the fundamental safeguards requirements and extraction of required system features, which is followed by analysis of suitable technologies and identification of technology gaps, and finally by development of a planning schedule for system improvements and new technology integration. Development of a comprehensive procedure will require the partnership and participation of the IAEA. The

  19. Closure and Sealing Design Calculation

    International Nuclear Information System (INIS)

    T. Lahnalampi; J. Case

    2005-01-01

    The purpose of the ''Closure and Sealing Design Calculation'' is to illustrate closure and sealing methods for sealing shafts, ramps, and identify boreholes that require sealing in order to limit the potential of water infiltration. In addition, this calculation will provide a description of the magma that can reduce the consequences of an igneous event intersecting the repository. This calculation will also include a listing of the project requirements related to closure and sealing. The scope of this calculation is to: summarize applicable project requirements and codes relating to backfilling nonemplacement openings, removal of uncommitted materials from the subsurface, installation of drip shields, and erecting monuments; compile an inventory of boreholes that are found in the area of the subsurface repository; describe the magma bulkhead feature and location; and include figures for the proposed shaft and ramp seals. The objective of this calculation is to: categorize the boreholes for sealing by depth and proximity to the subsurface repository; develop drawing figures which show the location and geometry for the magma bulkhead; include the shaft seal figures and a proposed construction sequence; and include the ramp seal figure and a proposed construction sequence. The intent of this closure and sealing calculation is to support the License Application by providing a description of the closure and sealing methods for the Safety Analysis Report. The closure and sealing calculation will also provide input for Post Closure Activities by describing the location of the magma bulkhead. This calculation is limited to describing the final configuration of the sealing and backfill systems for the underground area. The methods and procedures used to place the backfill and remove uncommitted materials (such as concrete) from the repository and detailed design of the magma bulkhead will be the subject of separate analyses or calculations. Post-closure monitoring will not

  20. Sealing properties of mechanical seals for an axial flow blood pump.

    Science.gov (United States)

    Tomioka, J; Mori, T; Yamazaki, K; Koyanagi, H

    1999-08-01

    A miniature intraventricular axial flow blood pump for left ventricular support is under development. One of the key technologies required for such pumps is sealing of the motor shaft. In this study, to prevent blood backflow into the motor side, mechanical seals were developed and their sealing properties investigated. In the experimental apparatus, the mechanical seal separated the bovine blood on the chamber side from the cooling water on the motor side. A leakage of the blood was measured by inductively coupled plasma (ICP) light emission analysis. The rate of hemolysis was measured by the cyanmethemoglobin method. Frictional torque acting on the shaft was measured by a torque transducer. In the experiments, the rotational speed of the shaft was changed from 1,000 to 10,000 rpm, and the contact force of the seal faces was changed from 1.96 to 4.31 N. To estimate lubrication regimes, the Stribeck curve, a diagram of the coefficient of friction against the bearing characteristic G number, was drawn. The results of the experiments showed that both the leakage of blood and the rate of hemolysis were very small. The friction loss was also very small. The mechanical seal was operated in various lubrication regimes, from a fluid lubrication regime to a mixed lubrication regime.

  1. Design and performance of a sealed CO2 laser for industrial applications

    International Nuclear Information System (INIS)

    Botero, G; Gomez, D; Nisperuza, D; Bastidas, A

    2011-01-01

    A large amount of materials processing is done using an industrial CO 2 laser operating in the mid-infrared (IR) spectrum. Their high efficiency and tremendous power output have made them one of the most commonly known transition wavelength at 10,6 microns facilitates laser cutting, drilling and marking of a wide variety of materials in the electronics and medical industries. Because lasers are feedback systems, many of their design parameters strongly interact with one another, and arriving at an optimum design requires a really thorough understanding of just how they interact. We report the construction of a sealed CO2 gas discharge laser with a glass laser tube design as well as clear acrylic housing makes this an excellent demonstrational tool. Sealed operation was characterized in mode, power, warm-up and stability over a long time. The results indicate a good operation, optimum wavelength, powers and beam quality will remove material more efficiently in effective industrial applications.

  2. Effects of an elastic membrane on tube waves in permeable formations

    Energy Technology Data Exchange (ETDEWEB)

    Liu, H; Johnson, D

    1996-10-01

    In this paper, the modified properties were calculated for tube wave propagation in a fluid-filled borehole penetrating a permeable rock due to the presence of a mudcake which forms on the borehole wall. The mudcake was characterized by an impermeable elastic layer. The mudcake partial sealing mechanism was simulated using a finite membrane stiffness. Consequently, it was shown that the mudcake can reduce, but not eliminate, the permeability effects on the tube wave slowness and attenuation. Moreover, this paper discusses a variety of values for the relevant parameters especially the mudcake thickness and membrane stiffness. The important combinations of mudcake parameters were clarified by using an analytic expression for the low-frequency limit.

  3. Investigating the sealing capacity of a seal system in rock salt (DOPAS project)

    Energy Technology Data Exchange (ETDEWEB)

    Jantschik, Kyra; Moog, Helge C.; Czaikowski, Oliver; Wieczorek, Klaus [Gesellschaft fuer Anlagen- und Reaktorsicherheit (GRS) gGmbH, Braunschweig (Germany)

    2016-11-15

    This paper describes research and development work on plugging and sealing repositories, an issue of fundamental importance for the rock salt option which represents one of the three European repository options, besides the clay rock and the crystalline rock options. The programme aims at providing experimental data needed for the theoretical analysis of the long-term sealing capacity of concrete- based sealing materials. In order to demonstrate hydro-mechanical material stability under representative load scenarios, a comprehensive laboratory testing programme is carried out. This comprises investigation of the sealing capacity of the combined seal system and impact of the so-called excavation-damaged zones (EDZ) as well as investigation of the hydro-chemical long-term stability of the seal in contact with different brines under diffusive and advective conditions. This paper presents experimental approaches and preliminary results from laboratory investigations on salt concrete and combined systems as obtained to date.

  4. [Ambulant treatment of wounds by vacuum sealing].

    Science.gov (United States)

    Ziegler, U E; Schmidt, K; Breithaupt, B; Menig, R; Debus, E S; Thiede, A

    2000-01-01

    The treatment of chronic wounds by vacuum sealing as an outpatient procedure is a new method of wound conditioning before closing the defect. The quality of life for the patient in his usual surrounding is maintained. Financial aspects also play a role in this treatment since costs for the health care system can be reduced. Various vacuum pumps, drainages and polymere foams are available and suitable for the outpatient treatment. The most important condition is to regularly check the vacuum. This can performed by the patient, the relatives or nursing staff. The main complication consists in loss of vacuum but technical and local or systemic complications can also appear. Individually applied vacuum dressings (polyvinyl foam, drainage tube and polymere foil) are practical. The ideal pump systems for the outpatient treatment are still not trial.

  5. Regenerator cross arm seal assembly

    Science.gov (United States)

    Jackman, Anthony V.

    1988-01-01

    A seal assembly for disposition between a cross arm on a gas turbine engine block and a regenerator disc, the seal assembly including a platform coextensive with the cross arm, a seal and wear layer sealingly and slidingly engaging the regenerator disc, a porous and compliant support layer between the platform and the seal and wear layer porous enough to permit flow of cooling air therethrough and compliant to accommodate relative thermal growth and distortion, a dike between the seal and wear layer and the platform for preventing cross flow through the support layer between engine exhaust and pressurized air passages, and air diversion passages for directing unregenerated pressurized air through the support layer to cool the seal and wear layer and then back into the flow of regenerated pressurized air.

  6. Aerial surveys of seals at Rødsand seal sanctuary and adjacent haul-out sites

    DEFF Research Database (Denmark)

    Teilmann, J.; Dietz, R.; Edren, Susi M.C.

    This report describes the preliminary results of aerial surveys at Rødsand seal sanctuary, southeast Denmark and adjacent seal haul-out sites in southwestern Baltic. The work was carried out in connection with studies of potential effects of the Nysted offshore wind farm. Rødsand seal sanctuary...... is a part of seal management area 4, and the area is believed to hold a more or less closed population with little exchange to other areas. Although the harbour seal is relatively stationary there may be movements between the haul-out sites in the area. A possible reaction to disturbance from...... the construction and operation of the wind farm may be that the seals use other haul-out sites to a higher extend....

  7. Ceramic/metal seals. [refractory materials for hermetic seals for lighium-metal sulfide batteries

    Science.gov (United States)

    Bredbenner, A. M.

    1977-01-01

    Design criteria are discussed for a hermetic seal capable of withstanding the 450 C operating temperature of a lithium-metal sulfide battery system. A mechanical seal consisting of two high strength alloy metal sleeves welded or brazed to a conductor assembly and pressed onto a ceramic is described. The conductor center passes through the ceramic but is not sealed to it. The seal is effected on the outside of the taper where the tubular part is pressed down over and makes contact.

  8. An Experimental Study on Shrinkage Strains of Normal-and High-Strength Concrete-Filled Frp Tubes

    Science.gov (United States)

    Vincent, Thomas; Ozbakkaloglu, Togay

    2017-09-01

    It is now well established that concrete-filled fiber reinforced polymer (FRP) tubes (CFFTs) are an attractive construction technique for new columns, however studies examining concrete shrinkage in CFFTs remain limited. Concrete shrinkage may pose a concern for CFFTs, as in these members the curing of concrete takes place inside the FRP tube. This paper reports the findings from an experimental study on concrete shrinkage strain measurements for CFFTs manufactured with normal- and high-strength concrete (NSC and HSC). A total of 6 aramid FRP (AFRP)-confined concrete specimens with circular cross-sections were manufactured, with 3 specimens each manufactured using NSC and HSC. The specimens were instrumented with surface and embedded strain gauges to monitor shrinkage development of exposed concrete and concrete sealed inside the CFFTs, respectively. All specimens were cylinders with a 152 mm diameter and 305 mm height, and their unconfined concrete strengths were 44.8 or 83.2 MPa. Analysis of the shrinkage measurements from concrete sealed inside the CFFTs revealed that embedment depth and concrete compressive strength only had minor influences on recorded shrinkage strains. However, an analysis of shrinkage measurements from the exposed concrete surface revealed that higher amounts of shrinkage can occur in HSC. Finally, it was observed that shrinkage strains are significantly higher for concrete exposed at the surface compared to concrete sealed inside the CFFTs.

  9. Nuclear instrumentation cable end seal

    International Nuclear Information System (INIS)

    Cannon, C.P.; Brown, D.P.

    1979-01-01

    An improved coaxial end seal for hermetically sealed nuclear instrumentation cable exhibiting an improved breakdown pulse noise characteristic under high voltage, high temperature conditions is described. A tubular insulator body has metallized interior and exterior surface portions which are braze sealed to a center conductor and an outer conductive sheath. The end surface of the insulator body which is directed toward the coaxial cable to which it is sealed has a recessed surface portion within which the braze seal material terminates

  10. Electrochemical and rheological behaviour of a fluid zinc paste; Comportement electrochimique et rheologique d`une pate de zinc fluide

    Energy Technology Data Exchange (ETDEWEB)

    Sajot, N.

    1997-12-04

    Zinc is a performing anodic material in numerous types of batteries. The anode of alkaline cells is typically a suspension of metallic powder in a gelled potassium hydroxide electrolyte, called zinc paste. We process such a homogeneous, fluid and stable paste, we study its physical electrochemical and rheological properties. Electrical power delivered during galvano-static electrolysis is about a few tens of mW.cm{sup -2} for anodic overvoltages inferior to 200 mV until the complete oxidation of the metal, 10 oxidation-reduction cycles are realised on paste samples of few mm width. In other respects, the product has a Bingham-type flow behavior, of critical shearing stress close to 200 Pa, and plastic viscosity about Pa.s, valid from 0,1 s{sup -1} shear rate. Zinc paste circulates in a slim rectangular section channel. Movement is ensured by a peristaltic pump placed on a cylindrical flexible tube. The paste transit between rectangular and circular sections is made through a profiled mechanical piece called a fish tail, without draft edge or roughness. An electrolytic separator and a current collector form the walls of the parallelopipedal channel, thus an electrolysis cell is framed. We record electrical and rheological characteristics of 2 oxidation-reduction cycles, during which the paste continues to flow and remains conductive. Established performances on the elementary cell allow to make up an air-zinc circulating paste battery for an electrical vehicle: the hydraulic recharge of a 100 l anodic paste tank is made in a few minutes, corresponding to a 300 km autonomy. (author) 87 refs.

  11. Turbine interstage seal with self-balancing capability

    Science.gov (United States)

    Mills, Jacob A; Jones, Russell B; Sexton, Thomas D

    2017-09-26

    An interstage seal for a turbine of a gas turbine engine, the interstage seal having a seal carrier with an axial extending seal tooth movable with a stator of the engine, and a rotor with a seal surface that forms the interstage seal with the seal tooth, where a magnetic force produced by two magnets and a gas force produced by a gas pressure acting on the seal carrier forms a balancing force to maintain a close clearance of the seal without the seal tooth contacting the rotor seal surfaces during engine operation. In other embodiments, two pairs of magnets produce first and second magnetic forces that balance the seal in the engine.

  12. Enhanced sealing project (ESP): evolution of a full-sized concrete and bentonite shaft seal

    International Nuclear Information System (INIS)

    Dixon, D.A.; Priyanto, D.G.; Martino, J.B.; De Combarieu, M.; Johansson, R.; Korkeakoski, P.; Villagran, J.

    2012-01-01

    Document available in extended abstract form only. A full-scale shaft seal was designed and installed in the 5-m-diameter access shaft at Atomic Energy of Canada's (AECL's) Underground Research Laboratory (URL) at the point where he shaft intersects an ancient water-bearing, low-angle thrust fault in granitic rock. The seal, part of the permanent closure of the URL, consists of a 6-m-thick bentonite-based component sandwiched between 3-m-thick upper and lower, 3-m-thick concrete components. The bentonite-based component spans the fracture zone and extends approximately 1 m beyond the maximum identified extent of the fracture. This design was adopted in order to limit water from the deeper, saline regions mixing with the fresher, near-surface groundwater regime. The concrete components provide the mechanical confinement and an in situ compacted 40/60 mixture of bentonite clay and quartz sand provides the sealing component. Construction of the shaft seal was done as part of Canada's Nuclear Legacies Liability Program. However, monitoring the seal evolution was not part of the decommissioning program's mandate. In addition to accomplishing the permanent closure of the URL, this seal's construction provides a unique opportunity to instrument and monitor the evolution of a full-scale shaft seal as well as the recovery of the regional groundwater regime as the facility passively floods above the seal. A jointly funded monitoring project was developed by NWMO (Canada), SKB (Sweden), Posiva (Finland) and ANDRA (France) and since mid 2009 the thermal, hydraulic and mechanical evolution of the seal has been constantly monitored. The evolution of the type of seal being monitored in the ESP is of relevance to repository closure planning, gaining confidence in the functionality of shaft seals. Although constructed in a crystalline rock medium, the results of the ESP are expected to be relevant to the performance of seals in a variety of host rock types. The shaft seal has been

  13. Sealing a conduit end

    International Nuclear Information System (INIS)

    Mentz, R.M.

    1993-01-01

    An apparatus for sealing or blocking conduits, such as the primary nozzles of a nuclear steam generator is described. It includes an annular bracket sealingly attached to the open end of the nozzle, the bracket having a plurality of threaded holes therein. Mounted atop the bracket is a generally circular nozzle dam for covering the opening. Interposed between the nozzle dam and the bracket is an extrusion-resistant seal member having a plurality of apertures therethrough for receiving each bolt. The seal member is configured to resist extrusion by having laminated layers of differing hardnesses, so that the seal member will not laterally extrude away from each bolt in a manner that enlarges the aperture surrounding each bolt as the nozzle dam is bolted to the bracket. (author)

  14. Converting an icebreaker from an oil lubricated stern tube bearing system to a seawater lubricated stern tube bearing considering environmental and operating costs

    Energy Technology Data Exchange (ETDEWEB)

    Ogle, Ken J.; Carter, Craig D. [Thordon Bearings Inc., Burlington, Ontario (Canada)], email: keno@thordonbearings.com, email: craigc@thordonbearings.com

    2010-07-01

    Icebreakers are prone to oil discharges from the stern tube, and lubricants that are biodegradable elsewhere may not be biodegradable enough in the Arctic and have a toxic effect on the food chain. The vulnerable element is the shaft seal, which must leak a small amount to operate in the first place, and ice milling causes very fast shaft movements that increase the leakage. Also, other objects such as fishing lines seriously compromise the operation of the seal. However, there is an alternative-namely the conversion of oil-lubricated bearings to Thordon COMPAC seawater-lubricated bearings. In this operation, white-metal bearings are replaced with Thordon non-metallic bearings; then, seawater is used as the lubrication and cooling medium. The seawater enters the front part of the stern, passes through the front and aft bearing before returning to the sea. This system totally eliminates the risk of polluting the Arctic ecosystem.

  15. Hermetic Seal Leak Detection Apparatus

    Science.gov (United States)

    Kelley, Anthony R. (Inventor)

    2013-01-01

    The present invention is a hermetic seal leak detection apparatus, which can be used to test for hermetic seal leaks in instruments and containers. A vacuum tight chamber is created around the unit being tested to minimize gas space outside of the hermetic seal. A vacuum inducing device is then used to increase the gas chamber volume inside the device, so that a slight vacuum is pulled on the unit being tested. The pressure in the unit being tested will stabilize. If the stabilized pressure reads close to a known good seal calibration, there is not a leak in the seal. If the stabilized pressure reads closer to a known bad seal calibration value, there is a leak in the seal. The speed of the plunger can be varied and by evaluating the resulting pressure change rates and final values, the leak rate/size can be accurately calculated.

  16. Investigation into the suitability of capillary tubes for microcrystalline testing.

    Science.gov (United States)

    Elie, Leonie E; Baron, Mark G; Croxton, Ruth S; Elie, Mathieu P

    2013-07-01

    A comparison between microcrystalline tests performed on microscope slides and flat capillary tubes with inner diameters ranging from 0.1 to 0.7 mm was carried out to explore the appropriateness of tubes for rapid testing of suspected drugs of abuse in the laboratory as well as in the field. Tests for mephedrone, cocaine, and phencyclidine were chosen as examples to investigate the handling of the capillary tubes, the influence on crystal habit, size, and the effects on the limit of detection. Image stacking software was used to increase the depth of field of micrographs taken from developed microcrystals greatly enhancing the interpretability even months after carrying out the microcrystalline test. Additionally, the potential of seeding capillary tubes with a reagent was studied. Pre-treatment of tubes would allow microcrystalline tests to be carried out quicker and anywhere without the necessity of taking along expensive and hazardous reagents. The sealing of capillary tubes containing developed microcrystalline tests in order to preserve results for a long period of time was successfully done by applying paraffin wax to the open ends. Finally, it was concluded that capillary tubes are suitable vessels for performing microcrystalline tests. The increased portability of the improved set-up allows tests to be safely executed outside laboratories without impairing the quality of the result. Findings were applied to six legal high samples purchased online between May and August 2011. The active ingredients like MDAI as well as cutting agents like caffeine were successfully identified using the microcrystalline test technique in capillary tubes. Copyright © 2012 John Wiley & Sons, Ltd.

  17. Zinc injection on the EDF fleet monitoring the injection on 12 units

    International Nuclear Information System (INIS)

    Le-Meur, Gaelle Harmand; Anne-Marie; Stutzmann, Agnes; Taunier, Stephane; Benfarah, Moez; Bretelle, Jean-Luc; Alain, Rocher; Claeys, Myriam; Bonne, Sebastien

    2012-09-01

    After a first implementation of zinc injection at Bugey 2 and Bugey 4, EDF decided to extend the program to other units of its fleet. 14 more reactors from the French fleet of 58 were chosen in order to - Reduce the radiation sources for curative or preventive (after SGR) reasons - Mitigate stress corrosion cracking on nickel alloys and reduce the rate of generalized corrosion - Prevent the risk of CIPS, mainly after a fuel management change. Zinc injection started on 9 new units in 2011, 1 unit in 2012 and will be extended to 4 other units before the end of 2013. To monitor the injection, EDF has defined a complete program concerning chemistry, radiation protection (dose rate and deposited activities measurements), materials (statistical analysis of SG tube cracks), fuel (oxide measurements) and waste (radiochemical characterization of filters). Reference units were chosen for each field because of the size of the fleet. This paper will detail the different monitoring programs on the EDF plants injecting zinc. (authors)

  18. Reusable, tamper-indicating seal

    International Nuclear Information System (INIS)

    Ryan, M.J.

    1978-01-01

    A reusable, tamper-indicating seal is comprised of a drum confined within a fixed body and rotatable in one direction therewithin, the top of the drum constituting a tray carrying a large number of small balls of several different colors. The fixed body contains parallel holes for looping a seal wire therethrough. The base of the drums carries cams adapted to coact with cam followers to lock the wire within the seal at one angular position of the drum. A channel in the fixed body, visible from outside the seal, adjacent the tray constitutes a segregated location for a small plurality of the colored balls. A spring in the tray forces colored balls into the segregated location at one angular position of the drum, further rotation securing the balls in position and the wires in the seal. A wedge-shaped plough removes the balls from the segregated location, at a different angular position of the drum, the wire being unlocked at the same postion. A new pattern of colored balls will appear in the segregated location when the seal is relocked

  19. Double angle seal forming lubricant film

    Science.gov (United States)

    Ernst, William D.

    1984-01-01

    A lubricated piston rod seal which inhibits gas leaking from a high pressure chamber on one side of the seal to a low pressure chamber on the other side of the seal. A liquid is supplied to the surface of the piston rod on the low pressure side of the seal. This liquid acts as lubricant for the seal and provides cooling for the rod. The seal, which can be a plastic, elastomer or other material with low elastic modulus, is designed to positively pump lubricant through the piston rod/seal interface in both directions when the piston rod is reciprocating. The capacity of the seal to pump lubricant from the low pressure side to the high pressure side is less than its capacity to pump lubricant from the high pressure side to the low pressure side which ensures that there is zero net flow of lubricant to the high pressure side of the seal. The film of lubricant between the seal and the rod minimizes any sliding contact and prevents the leakage of gas. Under static conditions gas leakage is prevented by direct contact between the seal and the rod.

  20. Shaft and tunnel sealing considerations

    International Nuclear Information System (INIS)

    Kelsall, P.C.; Shukla, D.K.

    1980-01-01

    Much of the emphasis of previous repository sealing research has been placed on plugging small diameter boreholes. It is increasingly evident that equal emphasis should now be given to shafts and tunnels which constitute more significant pathways between a repository and the biosphere. The paper discusses differences in requirements for sealing shafts and tunnels as compared with boreholes and the implications for seal design. Consideration is given to a design approach for shaft and tunnel seals based on a multiple component design concept, taking into account the requirements for retrievability of the waste. A work plan is developed for the future studies required to advance shaft and tunnel sealing technology to a level comparable with the existing technology for borehole sealing

  1. Rotatable seal assembly

    International Nuclear Information System (INIS)

    Garibaldi, J.L.; Logan, C.M.

    1982-01-01

    An assembly is provided for rotatably supporting a rotor on a stator so that vacuum chambers in the rotor and stator remain in communication while the chambers are sealed from ambient air, which enables the use of a ball bearing or the like to support most of the weight of the rotor. The apparatus includes a seal device mounted on the rotor to rotate therewith, but shiftable in position on the rotor while being sealed to the rotor as by an oring. The seal device has a flat face that is biased towards a flat face on the stator, and pressurized air is pumped between the faces to prevent contact between them while spacing them a small distance apart to avoid the inflow of large amounts of air between the faces and into the vacuum chambers

  2. Recent advances in magnetic liquid sealing

    International Nuclear Information System (INIS)

    Raj, K.; Stahl, P.; Bottenberg, W.; True, D.; Martis, G.; Zook, C.

    1979-01-01

    In this paper recent work in design and testing of two special magnetic liquid seals extending the state-of-the-art of ferrofluidic sealing is discussed. These custom seals are a moving belt edge seal and an exclusion seal. The first seal provides a hermetic barrier to solid particulates expected to be present in enclosed nuclear environments. The second seal is used on a magnetic disk drive spindle and reduces the particulate contaminants in the memory disk pack area by up to three orders of magnitude. In addition, bearing life in the spindle is found to be doubled due to reduction of operating temperature. The fundamentals of magnetic fluid sealing are presented in terms of magnetic circuit design and physical properties of ferrofluids

  3. Seal Related Development Activities at EG/G

    Science.gov (United States)

    Greiner, Harold F.

    1991-01-01

    Seal related development activities including modeling, analysis, and performance testing are described for several current seal related projects. Among the current seal related projects are the following: high pressure gas sealing systems for turbomachinery; brush seals for gas path sealing in gas turbines; and tribological material evaluation for wear surfaces in sealing systems.

  4. SEALING SIMULATED LEAKS

    Energy Technology Data Exchange (ETDEWEB)

    Michael A. Romano

    2004-09-01

    This report details the testing equipment, procedures and results performed under Task 7.2 Sealing Simulated Leaks. In terms of our ability to seal leaks identified in the technical topical report, Analysis of Current Field Data, we were 100% successful. In regards to maintaining seal integrity after pigging operations we achieved varying degrees of success. Internal Corrosion defects proved to be the most resistant to the effects of pigging while External Corrosion proved to be the least resistant. Overall, with limitations, pressure activated sealant technology would be a viable option under the right circumstances.

  5. Fog seal guidelines.

    Science.gov (United States)

    2003-10-01

    Fog seals are a method of adding asphalt to an existing pavement surface to improve sealing or waterproofing, prevent further stone loss by holding aggregate in place, or simply improve the surface appearance. However, inappropriate use can result in...

  6. Zinc metabolism in genetically obese mice

    International Nuclear Information System (INIS)

    Kennedy, M.L.; Failla, M.L.

    1986-01-01

    Recent reports indicate that the concentrations and total amounts of several essential trace metals in various tissues of genetically obese rodents differ markedly from lean controls. In the present studies the absorption, retention and tissue distribution of zinc was compared in obese (ob/ob) and lean (+/?) C57BL/6J mice. When administered 0.1 and 1 umole 65 Zn by stomach tube and killed after 4 h, fasted 10 week old obese mice had 2.7 and 2.2 times more radioactivity in their carcasses, respectively, than age-matched lean mice. Higher levels of 65 Zn were also present in the intestinal mucosa of obese mice. To eliminate possible differences in the effects of fasting and gastric emptying rates between the phenotypes, zinc absorption and retention were determined according to the method of Heth and Hoekstra. Analysis of data revealed that obese and lean mice absorbed 43 and 18% of the oral dose, respectively. Also, the rate of 65 Zn excretion between 2 and 6 days post-treatment was similar for obese and lean mice. After 6 days obese mice had significantly lower levels of radioisotope in skin, muscle plus bone, spleen and testes and higher levels of 65 Zn in liver, small intestine and adipose tissue compared to tissues from lean mice. These results demonstrate increased absorption, altered tissue distribution and similar excretion of zinc in ob/ob mice

  7. Reactor vessel sealing plug

    International Nuclear Information System (INIS)

    Dooley, R.A.

    1986-01-01

    An apparatus is described for sealing a cold leg nozzle of a nuclear reactor pressure vessel from a remote location comprising: at least one sealing plug for mechanically sealing the nozzle from the inside of the reactor pressure vessel. The sealing plug includes a plate and a cone assembly having an end part receptive in the nozzle, the plate being axially moveable relative to the cone assembly. The plate and cone assembly have confronting bevelled edges defining an opening therebetween. A primary O-ring is disposed about the opening and is supported on the bevelled edges, the plate being guidably mounted to the cone assembly for movement toward the cone assembly to radially expand the primary O-ring into sealing engagement with the nozzle. A means is included for providing relative movement between the outer plate and the cone assembly

  8. TiO2-Impregnated Porous Silica Tube and Its Application for Compact Air- and Water-Purification Units

    Directory of Open Access Journals (Sweden)

    Tsuyoshi Ochiai

    2015-09-01

    Full Text Available A simple, convenient, reusable, and inexpensive air- and water-purification unit including a one-end sealed porous amorphous-silica (a-silica tube coated with TiO2 photocatalyst layers has been developed. The porous a-silica layers were formed through outside vapor deposition (OVD. TiO2 photocatalyst layers were formed through impregnation and calcination onto a-silica layers. The resulting porous TiO2-impregnated a-silica tubes were evaluated for air-purification capacity using an acetaldehyde gas decomposition test. The tube (8.5 mm e.d. × 150 mm demonstrated a 93% removal rate for high concentrations (ca. 300 ppm of acetaldehyde gas at a single-pass condition with a 250 mL/min flow rate under UV irradiation. The tube also demonstrated a water purification capacity at a rate 2.0 times higher than a-silica tube without TiO2 impregnation. Therefore, the tubes have a great potential for developing compact and in-line VOC removal and water-purification units.

  9. Detection of seal contamination in heat-sealed food packaging based on active infrared thermography

    Science.gov (United States)

    D'huys, Karlien; Saeys, Wouter; De Ketelaere, Bart

    2015-05-01

    In the food industry packaging is often applied to protect the product from the environment, assuring quality and safety throughout shelf life if properly performed. Packaging quality depends on the material used and the closure (seal). The material is selected based on the specific needs of the food product to be wrapped. However, proper closure of the package is often harder to achieve. One problem possibly jeopardizing seal quality is the presence of food particles between the seal. Seal contamination can cause a decreased seal strength and thus an increased packaging failure risk. It can also trigger the formation of microchannels through which air and microorganisms can enter and spoil the enclosed food. Therefore, early detection and removal of seal-contaminated packages from the production chain is essential. In this work, a pulsed-type active thermography method using the heat of the sealing bars as an excitation source was studied for detecting seal contamination. The cooling profile of contaminated seals was recorded. The detection performance of four processing methods (based on a single frame, a fit of the cooling profile, pulsed phase thermography and a matched filter) was compared. High resolution digital images served as a reference to quantify contamination. The lowest detection limit (equivalent diameter of 0.63 mm) and the lowest processing time (0.42 s per sample) were obtained for the method based on a single frame. Presumably, practical limitations in the recording stage prevented the added value of active thermography to be fully reflected in this application.

  10. [Improvement in zinc nutrition due to zinc transporter-targeting strategy].

    Science.gov (United States)

    Kambe, Taiho

    2016-07-01

    Adequate intake of zinc from the daily diet is indispensable to maintain health. However, the dietary zinc content often fails to fulfill the recommended daily intake, leading to zinc deficiency and also increases the risk of developing chronic diseases, particularly in elderly individuals. Therefore, increased attention is required to overcome zinc deficiency and it is important to improve zinc nutrition in daily life. In the small intestine, the zinc transporter, ZIP4, functions as a component that is essential for zinc absorption. In this manuscript, we present a brief overview regarding zinc deficiency. Moreover, we review a novel strategy, called "ZIP4-targeting", which has the potential to enable efficient zinc absorption from the diet. ZIP4-targeting strategy is possibly a major step in preventing zinc deficiency and improving human health.

  11. Zinc content of selected tissues and taste perception in rats fed zinc deficient and zinc adequate rations

    International Nuclear Information System (INIS)

    Boeckner, L.S.; Kies, C.

    1986-01-01

    The objective of the study was to determine the effects of feeding zinc sufficient and zinc deficient rations on taste sensitivity and zinc contents of selected organs in rats. The 36 Sprague-Dawley male weanling rats were divided into 2 groups and fed zinc deficient or zinc adequate rations. The animals were subjected to 4 trial periods in which a choice of deionized distilled water or a solution of quinine sulfate at 1.28 x 10 -6 was given. A randomized schedule for rat sacrifice was used. No differences were found between zinc deficient and zinc adequate rats in taste preference aversion scores for quinine sulfate in the first three trial periods; however, in the last trial period rats in the zinc sufficient group drank somewhat less water containing quinine sulfate as a percentage of total water consumption than did rats fed the zinc deficient ration. Significantly higher zinc contents of kidney, brain and parotid salivary glands were seen in zinc adequate rats compared to zinc deficient rats at the end of the study. However, liver and tongue zinc levels were lower for both groups at the close of the study than were those of rats sacrificed at the beginning of the study

  12. Mercury free zinc alloy powder for alkaline manganese battery. 2. Effect of additive species to zinc particle on suppressing hydrogen gas evolution; Arukari mangan denchiyo mukoka aen gokin funmatsu. 2. Suiso gas hassei ni oyobosu aen ryushi eno tenka genso no yokusei koka

    Energy Technology Data Exchange (ETDEWEB)

    Yano, M.; Fujitani, S.; Nishio, K. [Sanyo electric Co. Ltd., Osaka (Japan); Akai, Y.; Kurimura, M. [Sanyo Excell Co. Ltd., Tottori (Japan)

    1997-08-05

    In order to make alkaline manganese batteries mercury-free and suppress hydrogen gas generation, investigations were given on the effect of additive species on modification of zinc particles present on negative electrode surface. Mercury with high hydrogen overvoltage has been added conventionally, but the mercury can cause an environmental problem. Surface modification by using indium exhibited hydrogen gas generation suppressing effect. With the surface modification amount of 0.10% by weight or more, the suppressing effect is saturated, reducing the effect to 50% of that of mercury. Surface-modifying the bismuth added zinc particles with indium showed greater suppressing effect than the case where each element is used independently. Zinc-indium (0.10% by weight) - bismuth (0.025% by weight) based alloy powder showed the same hydrogen generation suppressing effect as zinc-mercury (0.15% by weight) alloy powder. A sealed test battery using this alloy powder in negative active material exhibited a discharge capacity of 1700 mAh similarly to the initial stage even after having been stored for 20 days at 60 degC. Self-discharge characteristics equivalent to that of zinc-mercury (0.15% by weight) based alloy powder were obtained. An environment compatible dry cell battery containing no mercury whatsoever was developed successfully. 18 refs., 6 figs., 1 tab.

  13. Shaft Seal Compensates for Cold Flow

    Science.gov (United States)

    Myers, W. N.; Hein, L. A.

    1985-01-01

    Seal components easy to install. Ring seal for rotating or reciprocating shafts spring-loaded to compensate for slow yielding (cold flow) of sealing material. New seal relatively easy to install because components preassembled, then installed in one piece.

  14. Film riding seals for rotary machines

    Science.gov (United States)

    Bidkar, Rahul Anil; Sarawate, Neelesh Nandkumar; Wolfe, Christopher Edward; Ruggiero, Eric John; Raj Mohan, Vivek Raja

    2017-03-07

    A seal assembly for a rotary machine is provided. The seal assembly includes multiple sealing device segments disposed circumferentially intermediate to a stationary housing and a rotor. Each of the segments includes a shoe plate with a forward-shoe section and an aft-shoe section having one or more labyrinth teeth therebetween facing the rotor. The sealing device includes a stator interface element having a groove or slot for allowing disposal of a spline seal for preventing segment leakages. The sealing device segment also includes multiple bellow springs or flexures connected to the shoe plate and to the stator interface element. Further, the sealing device segments include a secondary seal integrated with the stator interface element at one end and positioned about the multiple bellow springs or flexures and the shoe plate at the other end.

  15. Low-Torque Seal Development

    Science.gov (United States)

    Lattime, Scott B.; Borowski, Richard

    2009-01-01

    The EcoTurn Class K production prototypes have passed all AAR qualification tests and received conditional approval. The accelerated life test on the second set of seals is in progress. Due to the performance of the first set, no problems are expected.The seal has demonstrated superior performance over the HDL seal in the test lab with virtually zero torque and excellent contamination exclusion and grease retention.

  16. Refrigeration system with clearance seals

    International Nuclear Information System (INIS)

    Holland, N. J.

    1985-01-01

    In a refrigeration system such as a split Stirling system, fluid seals associated with the reciprocating displacer are virtually dragless clearance seals. Movement of the displacer relative to the pressure variations in the working volume of gas is retarded by a discrete braking element. Because it is not necessary that the brake providing any sealing action, the brake can be designed for greater durability and less dependence on ambient and operating temperatures. Similarly, the clearance seal can be formed of elements having low thermal expansion such that the seal is not temperature dependent. In the primary embodiments the braking element is a split friction brake

  17. Reactor cavity seal ring

    International Nuclear Information System (INIS)

    Hankinson, M.F.

    1986-01-01

    A hydrostatic seal is described for sealing an annular gap between two flat substantially horizontal coplanar surfaces comprising, in combination: a generally flat annular plate of a width sufficient to span a gap between two surfaces: compressible annular sealing means disposed on the bottom surface of the flat annular plate for sealingly engaging the two flat surfaces in response to a downward force exerted on the plate; and fastening means, distributed along the center line of the plate, for releasably fastening the plate in a position to span the gap to be sealed and exert a downward force on the plate, each fastening means including a pair of elongated members of a size to fit into the gap to be sealed, means for mounting the members on the bottom surface of the plate so that at least a portion of each member is radially moveable in a direction toward a respective one of the vertical side surfaces defining the gap to be sealed to engage same and so that the plate is moveable relative to the members in a downward direction in response to hydrostatic pressure applied to the upper surface of the plate when the members are engaging the vertical side surfaces of an annular gap, and an actuating means, mounted on the plate for movement therewith in response to hydrostatic pressure, for radially moving the members, the actuating means extending through a bore in the plate to the upper surface of the plate

  18. Design considerations for mechanical face seals

    Science.gov (United States)

    Ludwig, L. P.; Greiner, H. F.

    1980-01-01

    Two companion reports deal with design considerations for improving performance of mechanical face seals, one of family of devices used in general area of fluid sealing of rotating shafts. One report deals with basic seal configuration and other with lubrication of seal.

  19. EBR-II rotating plug seal maintenance

    International Nuclear Information System (INIS)

    Allen, K.J.

    1986-01-01

    The EBR-II rotating plug seals require frequent cleaning and maintenance to keep the plugs from sticking during fuel handling. Time consuming cleaning on the cover gas and air sides of the dip ring seal is required to remove oxidation and sodium reaction products that accumulate and stop plug rotation. Despite severely limited access, effective seal cleaning techniques have removed 11 800 lb (5 352 kg) of deposits from the seals since 1964. Temperature control modifications and repairs have also required major maintenance work. Suggested seal design recommendations could significantly reduce maintenance on future similar seals

  20. Tamper-indicating quantum optical seals

    Energy Technology Data Exchange (ETDEWEB)

    Humble, Travis S [ORNL; Williams, Brian P [ORNL

    2015-01-01

    Confidence in the means for identifying when tampering occurs is critical for containment and surveillance technologies. Fiber-optic seals have proven especially useful for actively surveying large areas or inventories due to the extended transmission range and flexible layout of fiber. However, it is reasonable to suspect that an intruder could tamper with a fiber-optic sensor by accurately replicating the light transmitted through the fiber. In this contribution, we demonstrate a novel approach to using fiber-optic seals for safeguarding large-scale inventories with increased confidence in the state of the seal. Our approach is based on the use of quantum mechanical phenomena to offer unprecedented surety in the authentication of the seal state. In particular, we show how quantum entangled photons can be used to monitor the integrity of a fiber-optic cable - the entangled photons serve as active sensing elements whose non-local correlations indicate normal seal operation. Moreover, we prove using the quantum no-cloning theorem that attacks against the quantum seal necessarily disturb its state and that these disturbances are immediately detected. Our quantum approach to seal authentication is based on physical principles alone and does not require the use of secret or proprietary information to ensure proper operation. We demonstrate an implementation of the quantum seal using a pair of entangled photons and we summarize our experimental results including the probability of detecting intrusions and the overall stability of the system design. We conclude by discussing the use of both free-space and fiber-based quantum seals for surveying large areas and inventories.

  1. Repository Closure and Sealing Approach

    International Nuclear Information System (INIS)

    A.T. Watkins

    2000-01-01

    The scope of this analysis will be to develop the conceptual design of the closure seals and their locations in the Subsurface Facilities. The design will be based on the recently established program requirements for transitioning to the Site Recommendation (SR) design as outlined by ''Approach to Implementing the Site Recommendation Baseline'' (Stroupe 2000) and the ''Monitored Geologic Repository Project Description Document'' (CRWMS M andO 1999b). The objective of this analysis will be to assist in providing a description for the Subsurface Facilities System Description Document, Section 2 and finally to document any conclusions reached in order to contribute and provide support to the SR. This analysis is at a conceptual level and is considered adequate to support the SR design. The final closure barriers and seals for the ventilation shafts, and the north and south ramps will require these openings to be permanently sealed to limit excessive air and water inflows and prevent human intrusion. The major tasks identified with closure in this analysis are: (1) Developing the overall subsurface seal layout and identifying design and operational interfaces for the Subsurface Facilities. (2) Summarizing the general site conditions and general rock characteristic with respect to seal location and describing the seal selected. (3) Identify seal construction materials, methodology of construction and strategic locations including design of the seal and plugs. (4) Discussing methods to prevent human intrusion

  2. Contribution to the study of zinc and cadmium diffusions in InP and In0,97 Ga0,03 As0,08 P0,92 quaternary compound

    International Nuclear Information System (INIS)

    Tesser Junior, N.L.

    1986-01-01

    The zinc and cadmium diffusions in In 0,97 Ga 0,03 As 0,08 P 0,92 and InP, using sealed blister method, are studied. The consequences of fick law in diffusion processes are analysed. The diffusion measuring methods and carried out adjustments are described. (M.C.K.) [pt

  3. Air riding seal with purge cavity

    Science.gov (United States)

    Sexton, Thomas D; Mills, Jacob A

    2017-08-15

    An air riding seal for a turbine in a gas turbine engine, where an annular piston is axial moveable within an annular piston chamber formed in a stator of the turbine and forms a seal with a surface on the rotor using pressurized air that forms a cushion in a pocket of the annular piston. A purge cavity is formed on the annular piston and is connected to a purge hole that extends through the annular piston to a lower pressure region around the annular piston or through the rotor to an opposite side. The annular piston is sealed also with inner and outer seals that can be a labyrinth seal to form an additional seal than the cushion of air in the pocket to prevent the face of the air riding seal from overheating.

  4. Seals in nuclear reactors

    International Nuclear Information System (INIS)

    1979-01-01

    The aim of this invention is the provision of improved seals for reactor vessels in which fuel assemblies are located together with inlets and outlets for the circulation of a coolant. The object is to provide a seal arrangement for the rotatable plugs of nuclear reactor closure heads which has good sealing capacities over a wide gap during operation of the reactor but which also permits uninhibited rotation of the plugs for maintenance. (U.K.)

  5. Self-acting and hydrodynamic shaft seals

    Science.gov (United States)

    Ludwig, L. P.

    1973-01-01

    Self-acting and hydrodynamic seals are described. The analytical procedures are outlined for obtaining a seal force balance and the operating film thickness. Particular attention is given to primary ring response (seal vibration) to rotating seat face runout. This response analysis revealed three different vibration modes. Proposed applications of self-acting seals in gas turbine engines and in rocket vehicle turbopumps are described. Also experimental data on self-acting face seals operating under simulated gas turbine conditions are given; these data show the feasibility of operating the seal at conditions of 345 newtons per square centimeter (500 psi) and 152 meters per second (500 ft/sec) sliding speed.

  6. Radial lip seals, thermal aspects

    NARCIS (Netherlands)

    Stakenborg, M.J.L.; van Ostaijen, R.A.J.; Dowson, D.

    1989-01-01

    In this paper the influence of temperature on tne seal-snarc contact is studied, using coupled temperature-stress FEH analysis. A thermal network model is used to calculate the seal-shaft contact temperature for steady-state and transient conditions. Contact temperatures were measured under the seal

  7. Does the oral zinc tolerance test measure zinc absorption

    Energy Technology Data Exchange (ETDEWEB)

    Valberg, L.S.; Flanagan, P.R.; Brennan, J.; Chamberlain, M.J.

    1985-01-01

    Increases in plasma zinc concentration were compared with radiozinc absorption after oral test doses. Ten healthy, fasting subjects were each given 385 mumol zinc chloride (25 mg Zn) labelled with 0.5 muCi /sup 65/ZnCl/sub 2/ and a non-absorbed marker, /sup 51/CrCl/sub 3/, dissolved in 100 ml of water; another 10 persons were given 354 mumol zinc chloride and 125 g of minced turkey containing 31 mumol zinc also labelled with /sup 65/Zn and /sup 51/Cr. Measurements were made of plasma zinc concentration at hourly intervals for 5 hours, radiozinc absorption by stool counting of unabsorbed radioactivity 12-36 hours later, and radiozinc retention by whole body counting at 7 days. The mean percentage of radiozinc absorbed and retained in the body from the two test meals was found to be identical (42%). In contrast the increased area under the plasma zinc curve up to 5 hours after the turkey meal, 28 +/- 9 mumol/L (mean +/- SD) was significantly less than that for zinc chloride alone, 47 +/- 15 mumol/L, p less than 0.005. Despite this difference, a good correlation was found between the area under the plasma zinc curve and /sup 65/Zn absorption in individual subjects after each meal. The discrepancy between the results of zinc absorption derived from the plasma zinc curve and /sup 65/Zn absorption for the liquid and solid test meals was most likely explained by binding of zinc to food and delayed gastric emptying of the solid meal. With a test meal of turkey meat at least this dampened the plasma appearance of zinc but did not affect its overall absorption.

  8. Does the oral zinc tolerance test measure zinc absorption

    International Nuclear Information System (INIS)

    Valberg, L.S.; Flanagan, P.R.; Brennan, J.; Chamberlain, M.J.

    1985-01-01

    Increases in plasma zinc concentration were compared with radiozinc absorption after oral test doses. Ten healthy, fasting subjects were each given 385 mumol zinc chloride (25 mg Zn) labelled with 0.5 muCi 65 ZnCl 2 and a non-absorbed marker, 51 CrCl 3 , dissolved in 100 ml of water; another 10 persons were given 354 mumol zinc chloride and 125 g of minced turkey containing 31 mumol zinc also labelled with 65 Zn and 51 Cr. Measurements were made of plasma zinc concentration at hourly intervals for 5 hours, radiozinc absorption by stool counting of unabsorbed radioactivity 12-36 hours later, and radiozinc retention by whole body counting at 7 days. The mean percentage of radiozinc absorbed and retained in the body from the two test meals was found to be identical (42%). In contrast the increased area under the plasma zinc curve up to 5 hours after the turkey meal, 28 +/- 9 mumol/L (mean +/- SD) was significantly less than that for zinc chloride alone, 47 +/- 15 mumol/L, p less than 0.005. Despite this difference, a good correlation was found between the area under the plasma zinc curve and 65 Zn absorption in individual subjects after each meal. The discrepancy between the results of zinc absorption derived from the plasma zinc curve and 65 Zn absorption for the liquid and solid test meals was most likely explained by binding of zinc to food and delayed gastric emptying of the solid meal. With a test meal of turkey meat at least this dampened the plasma appearance of zinc but did not affect its overall absorption

  9. Airfoil seal system for gas turbine engine

    Science.gov (United States)

    None, None

    2013-06-25

    A turbine airfoil seal system of a turbine engine having a seal base with a plurality of seal strips extending therefrom for sealing gaps between rotational airfoils and adjacent stationary components. The seal strips may overlap each other and may be generally aligned with each other. The seal strips may flex during operation to further reduce the gap between the rotational airfoils and adjacent stationary components.

  10. Endotracheal tube cuff pressure monitoring during neurosurgery - Manual vs. automatic method

    Directory of Open Access Journals (Sweden)

    Mukul Kumar Jain

    2011-01-01

    Full Text Available Background: Inflation and assessment of the endotracheal tube cuff pressure is often not appreciated as a critical aspect of endotracheal intubation. Appropriate endotracheal tube cuff pressure, endotracheal intubation seals the airway to prevent aspiration and provides for positive-pressure ventilation without air leak. Materials and Methods: Correlations between manual methods of assessing the pressure by an experienced anesthesiologists and assessment with maintenance of the pressure within the normal range by the automated pressure controller device were studied in 100 patients divided into two groups. In Group M, endotracheal tube cuff was inflated manually by a trained anesthesiologist and checked for its pressure hourly by cuff pressure monitor till the end of surgery. In Group C, endotracheal tube cuff was inflated by automated cuff pressure controller and pressure was maintained at 25-cm H 2 O throughout the surgeries. Repeated measure ANOVA was applied. Results: Repeated measure ANOVA results showed that average of endotracheal tube cuff pressure of 50 patients taken at seven different points is significantly different (F-value: 171.102, P-value: 0.000. Bonferroni correction test shows that average of endotracheal tube cuff pressure in all six groups are significantly different from constant group (P = 0.000. No case of laryngomalacia, tracheomalacia, tracheal stenosis, tracheoesophageal fistula or aspiration pneumonitis was observed. Conclusions: Endotracheal tube cuff pressure was significantly high when endotracheal tube cuff was inflated manually. The known complications of high endotracheal tube cuff pressure can be avoided if the cuff pressure controller device is used and manual methods cannot be relied upon for keeping the pressure within the recommended levels.

  11. Sealing of 300 mm boreholes KXTT3 and KXTT4 at Aespoe HRL. Report of Subproject 3 of Borehole sealing Project

    Energy Technology Data Exchange (ETDEWEB)

    Pusch, Roland [Drawrite AB, Lund (Sweden); Luleaa Technical Univ., Luleaa (Sweden); Ramqvist, Gunnar [Eltekno AB, Figeholm (Sweden)

    2011-11-15

    Sealing of two moderately dipping 300 mm diameter holes that had been bored from a niche adjacent to the ramp in the Aespoe URL in conjunction with earlier geohydrological investigations (TRUE Project, Winberg et al. 2000) was successfully completed in early 2010. The work was preceded by a pilot test on the ground surface for investigating if a simple version of sealing by pressing down clay pellets into clay mud is feasible. The borehole was simulated by a steel tube that was filled with smectite mud in which a cage filled with clay pellets was moved down. The experience from this experiment was that the mud used was somewhat too stiff and that strong vibration significantly reduced its viscosity but not sufficiently much. The predicted average density at water saturation was 1,780 kg/m{sup 3} (dry density 1,240 kg/m{sup 3}). The finally selected sealing method comprised casting of concrete plugs where the inflow of water was significant (up to 30 l/min), and to install precompacted blocks of smectite-rich clay where the rock was 'dry'. The finally matured clay plugs will have a density of around 2,000 kg/m{sup 3} (dry density 1,580 kg/m{sup 3}) and a hydraulic conductivity of less than E-12 m/s, which is estimated to be at least one order of magnitude lower than the bulk conductivity of the surrounding rock mass (Pusch 2008). This provides excellent sealing of all parts of the holes deeper than about 1-2 m below the tunnel floor. Groundwater flow in the rock around the clay plugs can cause some minor erosion but this effect is deemed negligible considering the coagulating effect on released clay particles by the brackish Aespoe water. Inspection of the closed upper borehole ends showed accumulation of some very dilute mineral suspension after a few days. A careful analysis of the mineral content showed that it did not contain smectite particles, hence certifying that erosion of the clay plugs in the holes had not taken place. The particles were

  12. Sealing of 300 mm boreholes KXTT3 and KXTT4 at Aespoe HRL. Report of Subproject 3 of Borehole sealing Project

    International Nuclear Information System (INIS)

    Pusch, Roland; Ramqvist, Gunnar

    2011-11-01

    Sealing of two moderately dipping 300 mm diameter holes that had been bored from a niche adjacent to the ramp in the Aespoe URL in conjunction with earlier geohydrological investigations (TRUE Project, Winberg et al. 2000) was successfully completed in early 2010. The work was preceded by a pilot test on the ground surface for investigating if a simple version of sealing by pressing down clay pellets into clay mud is feasible. The borehole was simulated by a steel tube that was filled with smectite mud in which a cage filled with clay pellets was moved down. The experience from this experiment was that the mud used was somewhat too stiff and that strong vibration significantly reduced its viscosity but not sufficiently much. The predicted average density at water saturation was 1,780 kg/m 3 (dry density 1,240 kg/m 3 ). The finally selected sealing method comprised casting of concrete plugs where the inflow of water was significant (up to 30 l/min), and to install precompacted blocks of smectite-rich clay where the rock was 'dry'. The finally matured clay plugs will have a density of around 2,000 kg/m 3 (dry density 1,580 kg/m 3 ) and a hydraulic conductivity of less than E-12 m/s, which is estimated to be at least one order of magnitude lower than the bulk conductivity of the surrounding rock mass (Pusch 2008). This provides excellent sealing of all parts of the holes deeper than about 1-2 m below the tunnel floor. Groundwater flow in the rock around the clay plugs can cause some minor erosion but this effect is deemed negligible considering the coagulating effect on released clay particles by the brackish Aespoe water. Inspection of the closed upper borehole ends showed accumulation of some very dilute mineral suspension after a few days. A careful analysis of the mineral content showed that it did not contain smectite particles, hence certifying that erosion of the clay plugs in the holes had not taken place. The particles were concluded to represent fracture

  13. Analysis on the Viscous Pumping in a Magnetic Fluid Seal Under a Rotating Load and the Seal Design

    OpenAIRE

    長屋, 幸助; 大沼, 浩身; 佐藤, 淳

    1990-01-01

    This paper discusses effects of viscous pumping in a magnetic fluid seal under a rotating load. The Reynolds equation was presented for the seal based on magnetic fluid mechanics, and the expressions for obtaining pressures in the seal, eccentricities of the rotating shaft due to the viscous pumping and seal pressures were given. Numerical Calculations were carried out for some sample problems, and the effect of magnetic flux densities on the pressure in the seal and the seal pressures were c...

  14. Albinistic common seals (Phoca vitulina) and melanistic grey seals (Halichoerus grypus) rehabilitated in the Netherlands

    NARCIS (Netherlands)

    Osinga, Nynke; 't Hart, Pieter; Vader, Pieter C. van Voorst

    2010-01-01

    The Seal Rehabilitation and Research Centre (SRRC) in Pieterburen, The Netherlands, rehabilitates seals from the waters of the Wadden Sea, North Sea and Southwest Delta area. Incidental observations of albinism and melanism in common and grey seals are known from countries surrounding the North Sea.

  15. Investigation of impingement attack mechanism of copper alloy condenser tubes

    Energy Technology Data Exchange (ETDEWEB)

    Fukumura, Takuya; Nakajima, Nobuo; Arioka, Koji; Totsuka, Nobuo; Nakagawa, Tomokazu [Institute of Nuclear Safety System Inc., Mihama, Fukui (Japan)

    2001-09-01

    In order to investigate generation and growth mechanisms of impingement attacks of sea water against copper alloy condenser tubes used in condensers of nuclear power plants, we took out condenser tubes from actual condensers, cut them into several pieces and carried out several material tests mainly for impinged spots. In addition water flow inside of a pit was analyzed. From the results of the investigation, it was found that all of impingement attacks were found in the marks left by sessile organisms and none were found in downstream of the marks as frequently proposed so far. At the pits generated inside the marks, iron coating was striped and zinc content was deficient in some cases. Combining these data and the result of flow analysis, we considered the following mechanism of the impingement attacks: sessile organisms clinging to the surface of the condenser tube and growth, occlusion of the tube, extinction and decomposition of sessile organisms, pollution corrosion under the organisms and cavity formation, occlusion removal by the cleaning, generation of impingement attacks by flow collision inside the cavity, growth of the impingement attacks. (author)

  16. Enhanced sealing project: monitoring the THM response of a full-scale shaft seal

    Energy Technology Data Exchange (ETDEWEB)

    Dixon, D.A.; Martino, J.B.; Holowick, B.; Priyanto, D. [Atomic Energy of Canada Limited, Pinawa, MB (Canada)

    2011-07-01

    Closure of the subsurface facilities at Atomic Energy of Canada Limited's (AECL) Underground Research Laboratory (URL) was completed in 2010 with installation of a concrete surface cap. Additionally, as part of decommissioning, seals were installed at the penetration of the shafts through the major hydro-geological feature known as Fracture Zone 2 (FZ2). The seal construction was funded by Natural Resources Canada (NRCan) under the Nuclear Legacy Liabilities Program (NLLP). The shaft seals at the URL were based on the composite seal concept developed for application in a deep geological repository for disposal of used nuclear fuel. The access shaft seal consists of two 3-m thick concrete segments that rigidly confine a 6-m long section of swelling clay-based material (40% bentonite clay - 60% sand by dry mass). Monitoring of the regional groundwater recovery following flooding of the lower shaft is a closure requirement and was included in the design. It was widely recognized that the installation of the seals at the URL represented a unique opportunity to monitor the evolution of the type of seal that might be installed in an actual repository but the NLLP mandate did not include any monitoring of shaft seal evolution. As a result the Enhanced Sealing Project (ESP) partnership composed of NWMO, Posiva, SKB and ANDRA was established and a set of 68 instruments (containing 100 sensors) were installed to monitor the evolution of the seal. In the first year of operation sensors have monitored the following parameters in the ESP: thermal evolution and strain of the concrete components, thermal, hydraulic and mechanical changes in the clay component and its contacts with the rock and concrete confinement. Additionally, monitoring of the near-field and regional groundwater evolution has been undertaken. Monitoring of the short-term thermal-mechanical evolution of the concrete components was successfully accomplished and only a small temperature rise occurred due to

  17. Enhanced sealing project: monitoring the THM response of a full-scale shaft seal

    International Nuclear Information System (INIS)

    Dixon, D.A.; Martino, J.B.; Holowick, B.; Priyanto, D.

    2011-01-01

    Closure of the subsurface facilities at Atomic Energy of Canada Limited's (AECL) Underground Research Laboratory (URL) was completed in 2010 with installation of a concrete surface cap. Additionally, as part of decommissioning, seals were installed at the penetration of the shafts through the major hydro-geological feature known as Fracture Zone 2 (FZ2). The seal construction was funded by Natural Resources Canada (NRCan) under the Nuclear Legacy Liabilities Program (NLLP). The shaft seals at the URL were based on the composite seal concept developed for application in a deep geological repository for disposal of used nuclear fuel. The access shaft seal consists of two 3-m thick concrete segments that rigidly confine a 6-m long section of swelling clay-based material (40% bentonite clay - 60% sand by dry mass). Monitoring of the regional groundwater recovery following flooding of the lower shaft is a closure requirement and was included in the design. It was widely recognized that the installation of the seals at the URL represented a unique opportunity to monitor the evolution of the type of seal that might be installed in an actual repository but the NLLP mandate did not include any monitoring of shaft seal evolution. As a result the Enhanced Sealing Project (ESP) partnership composed of NWMO, Posiva, SKB and ANDRA was established and a set of 68 instruments (containing 100 sensors) were installed to monitor the evolution of the seal. In the first year of operation sensors have monitored the following parameters in the ESP: thermal evolution and strain of the concrete components, thermal, hydraulic and mechanical changes in the clay component and its contacts with the rock and concrete confinement. Additionally, monitoring of the near-field and regional groundwater evolution has been undertaken. Monitoring of the short-term thermal-mechanical evolution of the concrete components was successfully accomplished and only a small temperature rise occurred due to

  18. Influence of DNA-methylation on zinc homeostasis in myeloid cells: Regulation of zinc transporters and zinc binding proteins.

    Science.gov (United States)

    Kessels, Jana Elena; Wessels, Inga; Haase, Hajo; Rink, Lothar; Uciechowski, Peter

    2016-09-01

    The distribution of intracellular zinc, predominantly regulated through zinc transporters and zinc binding proteins, is required to support an efficient immune response. Epigenetic mechanisms such as DNA methylation are involved in the expression of these genes. In demethylation experiments using 5-Aza-2'-deoxycytidine (AZA) increased intracellular (after 24 and 48h) and total cellular zinc levels (after 48h) were observed in the myeloid cell line HL-60. To uncover the mechanisms that cause the disturbed zinc homeostasis after DNA demethylation, the expression of human zinc transporters and zinc binding proteins were investigated. Real time PCR analyses of 14 ZIP (solute-linked carrier (SLC) SLC39A; Zrt/IRT-like protein), and 9 ZnT (SLC30A) zinc transporters revealed significantly enhanced mRNA expression of the zinc importer ZIP1 after AZA treatment. Because ZIP1 protein was also enhanced after AZA treatment, ZIP1 up-regulation might be the mediator of enhanced intracellular zinc levels. The mRNA expression of ZIP14 was decreased, whereas zinc exporter ZnT3 mRNA was also significantly increased; which might be a cellular reaction to compensate elevated zinc levels. An enhanced but not significant chromatin accessibility of ZIP1 promoter region I was detected by chromatin accessibility by real-time PCR (CHART) assays after demethylation. Additionally, DNA demethylation resulted in increased mRNA accumulation of zinc binding proteins metallothionein (MT) and S100A8/S100A9 after 48h. MT mRNA was significantly enhanced after 24h of AZA treatment also suggesting a reaction of the cell to restore zinc homeostasis. These data indicate that DNA methylation is an important epigenetic mechanism affecting zinc binding proteins and transporters, and, therefore, regulating zinc homeostasis in myeloid cells. Copyright © 2016 Elsevier GmbH. All rights reserved.

  19. 19 CFR 113.25 - Seals.

    Science.gov (United States)

    2010-04-01

    ... signatures of principal and surety, if individuals, and the corporate seal shall be affixed close to the... law of the state in which executed. However, when the charter or governing statute of a corporation requires its acts to be evidenced by its corporate seal, such seal is required. ...

  20. Obtention of brachytherapy seeds by sealing process using polymer; Obtencao de sementes de braquiterapia pelo processo de selagem com polimero

    Energy Technology Data Exchange (ETDEWEB)

    Lana, Diogo Alberto P.D.; Ferraz, Wilmar B.; Santos, Ana Maria M., E-mail: amms@cdtn.br [Centro de Desenvolvimento da Tecnologia Nuclear (CDTN/CNEN-MG), Belo Horizonte, MG (Brazil); Carvalho, Luiz Claudio F.M. Garcia [Universidade Federal de Minas Gerais (UFMG), Belo Horizonte, MG (Brazil)

    2012-08-15

    Brachytherapy is an advanced cancer treatment where radioactive seeds or sources are placed near or directly into the tumor thus reducing the radiation exposure in the surrounding healthy tissues. Several kinds of seeds have been developed in order to obtain a better dose distribution around them and with a lower cost manufacturing. These seeds consist of an encapsulation (titanium or stainless steel tube), a radionuclide carrier, and X-ray marker. The usual sealing process of the seeds is done with laser welding, but this process can promote radionuclide volatilization. In this paper, we present a new sealing process using epoxy resin and characterizations of two epoxy resins. These resins were characterized by Fourier transform infrared spectroscopic (FTIR), ultraviolet-visible spectroscopy (UV-vis) and differential scanning calorimetry (DSC). Interactions of the resins and of the sealed seeds in a simulated body fluid (SBF) were evaluated by scanning electron microscopy (SEM), energy dispersive X-ray spectroscopy (EDS), and by a counting gamma-rays. (author)

  1. Optimization and studies of the welding processes, automation of the sealing welding system and fracture mechanics in the vessels surveillance in nuclear power plants

    International Nuclear Information System (INIS)

    Gama R, G.

    2011-01-01

    Inside this work the optimization of two welding systems is described, as well as the conclusion of a system for the qualification of containers sealing in the National Institute of Nuclear Research that have application in the surveillance programs of nuclear reactors vessels and the correspondent extension of the operation license. The test tubes Charpy are assay to evaluate the embrittlement grade, when obtaining the increment in the reference temperature and the decrease of the absorbed maximum energy, in the transition curve fragile-ductile of the material. After the test two test tube halves are obtained that should take advantage to follow the surveillance of the vessel and their possible operation extension, this is achieved by means of rebuilding (being obtained of a tested test tube two reconstituted test tubes). The welding system for the rebuilding of test tubes Charpy, was optimized when diminishing the union force at solder, achieving the elimination of the rejection for penetration lack for spill. For this work temperature measurements were carried out at different distances of the welding interface from 1 up to 12 mm, obtaining temperature profiles. With the maximum temperatures were obtained a graph and equation that represents the maximum temperature regarding the distance of the interface, giving as a result practical the elimination of other temperature measurements. The reconstituted test tubes were introduced inside pressurized containers with helium of ultra high purity to 1 pressure atmosphere. This process was carried out in the welding system for containers sealing, where an automatic process was implemented by means of an application developed in the program LabVIEW, reducing operation times and allowing the remote control of the process, the acquisition parameters as well as the generation of welding reports, avoiding with this the human error. (Author)

  2. Method of capturing or trapping zinc using zinc getter materials

    Science.gov (United States)

    Hunyadi Murph, Simona E.; Korinko, Paul S.

    2017-07-11

    A method of trapping or capturing zinc is disclosed. In particular, the method comprises a step of contacting a zinc vapor with a zinc getter material. The zinc getter material comprises nanoparticles and a metal substrate.

  3. Upgrading primary heat transport pump seals

    International Nuclear Information System (INIS)

    Graham, T.; Metcalfe, R.; Rhodes, D.; McInnes, D.

    1995-01-01

    Changes in the operating environment at the Bruce-A Nuclear Generating Station created the need for an upgraded Primary Heat Transport Pump (PHTP) seal. In particular, the requirement for low pressure running during more frequent start-ups exposed a weakness of the CAN2 seal and reduced its reliability. The primary concern at Bruce-A was the rotation of the CAN2 No. 2 stators in their holders. The introduction of low pressure running exacerbated this problem, giving rapid wear of the stator back face, overheating, and thermocracking. In addition, the resulting increase in friction between the stator and its holder increased stationary-side hysteresis and thereby changed the seal characteristic to the point where interseal pressure oscillations became prevalent. The resultant increased hysteresis also led to hard rubbing of the seal faces during temperature transients. An upgraded seal was required for improved reliability to avoid forced outages and to reduce maintenance costs. This paper describes this upgraded 'replacement seal' and its performance history. In spite of the 'teething' problems detailed in this paper, there have been no forced outages due to the replacement seal, and in the words of a seal maintenance worker at Bruce-A, 'it allows me to go home and sleep at night instead of worrying about seal failures.' (author)

  4. Advanced High Temperature Structural Seals

    Science.gov (United States)

    Newquist, Charles W.; Verzemnieks, Juris; Keller, Peter C.; Rorabaugh, Michael; Shorey, Mark

    2002-10-01

    This program addresses the development of high temperature structural seals for control surfaces for a new generation of small reusable launch vehicles. Successful development will contribute significantly to the mission goal of reducing launch cost for small, 200 to 300 pound payloads. Development of high temperature seals is mission enabling. For instance, ineffective control surface seals can result in high temperature (3100 F) flows in the elevon area exceeding structural material limits. Longer sealing life will allow use for many missions before replacement, contributing to the reduction of hardware, operation and launch costs.

  5. SCC testing of steam generator tubes repaired by welded sleeves

    International Nuclear Information System (INIS)

    Pierson, E.; Stubbe, J.

    1993-01-01

    One way to repair steam generator tubing is to introduce a sleeve inside the tube so that it spans the corroded area and to seal it at both ends. This technique has been studied at Laborelec with a particular attention paid to the occurrence of new SCC cracks at the upper joint. Tube segments coming from the same lot of mill annealed alloy 600 were sent to six manufacturers to be sleeved by their own procedure (including TIG, laser or kinetic welding, followed or not by a stress relief heat treatment), and then tested at Laborelecin 10% NaOH at 350 degrees C. The tests were performed with and without differential pressure i.e. in capsules (Δ = 9 and 19 MPa) and in autoclave (Δp = 0). Nearly all the not stress relieved mock-ups developed through cracks in several hundred hours in auto-clave. The cracks were circumferential and situated near the weld. At 9 and 19 MPa, the time to failure decreased and longitudinal cracks appeared near the weld and at the transition zone of expanded areas. Cracks were never observed in the alloy 690 sleeve, except in the weld bead. Reference capsules (roll expaned tubes) made of the same lot of alloy 600 were tested in the same environment

  6. Upgrading inflatable door seals

    International Nuclear Information System (INIS)

    Sykes, T.M.; Metcalfe, R.; Welch, L.A.; Josefowich, J.M.

    1997-01-01

    Inflatable door seals are used for airlocks in CANDU stations. They have been a significant source of unreliability and maintenance cost. A program is underway to improve their performance and reliability, backed by environmental qualification testing. Only commercial products and suppliers existed in 1993. For historical reasons, these 'existing products' did not use the most durable material then available. In hindsight, neither had they been adapted nor optimized to combat conditions often experienced in the plants-sagging doors, damaged sealing surfaces, and many thousands of openings and closings per year. Initial attempts to involve the two existing suppliers in efforts to upgrade these seals were unsuccessful. Another suitable supplier had therefore to be found, and a 'new,' COG-owned seal developed; this was completed in 1997. This paper summarizes its testing, along with that of the two existing products. Resistance to aging has been improved significantly. Testing has shown that an accident can be safely withstood after 10 years of service or 40,000 openings-closings, whichever comes first. AECL's Fluid Sealing Technology Unit (FSTU) has invested in the special moulds, test fixtures and other necessary tooling and documentation required to begin commercial manufacture of this new quality product. Accordingly, as with FSTU's other nuclear products such as pump seals, the long-term supply of door seals to CANDU plants is now protected from many external uncertainties-e.g., commercial products being discontinued, materials being changed, companies going out of business. Manufacturing to AECL's detailed specifications is being subcontracted to the new supplier. FSTU is performing the quality surveillance, inspection, testing, and customer service activities concomitant with direct responsibility for supply to the plants. (author)

  7. Zinc injection on the EDF pressurized light water reactors. Current results and operating experience feedback

    International Nuclear Information System (INIS)

    Piana, Olivier; Duval, Arnaud; Moleiro, Edgar; Benfarah, Moez; Bretelle, Jean-Luc; Chaigne, Guy

    2014-01-01

    Nowadays, zinc injection, as well as pH management and hydrogen control, is increasingly considered as an essential element of PWR Primary Water Chemistry worldwide. After a first implementation of zinc injection at Bugey 2 since 2004 and Bugey 4 since 2006, EDF decided to extend this practice, which constitutes a modification of primary circuit chemical conditioning, to other units of its fleet. Currently, 15 among the 58 reactors of the French fleet are injecting depleted zinc acetate into the primary coolant water. Three main goals were identified at the beginning of this program. Indeed, the expected benefits of zinc injection were: Reduction of the rate of generalized corrosion and mitigation of stress corrosion cracking initiation on nickel based alloys (Material goal). Curative or preventive reduction of radiation sources to which workers are exposed (Radiation fields' goal). Mitigation of the AOA or CIPS risks by reduction of corrosion products releases and mitigation of crud deposition (Fuel protection goal). To monitor the zinc addition, EDF has defined a complete survey program concerning: chemistry and radiochemistry responses (primary coolant monitoring of corrosion and fission products and calculation of zinc injected, zinc removed and zinc incorporated in RCS surfaces) ; radiation fields (dose rates and deposited activities measurements) ; materials (statistical analysis of SG tube cracks) ; fuel (oxide thickness measurements and visual exams) ; effluents (corrosion products releases and isotopic distribution follow up) ; wastes (radiochemical characterization of filters). This paper will detail the present results of this monitoring program. It appears that the expected benefits of zinc injection have yet to be fully realized; further operating experience will be required in order to fully evaluate its impact. (author)

  8. Fiber Optic Safeguards Sealing System

    Science.gov (United States)

    1978-01-01

    8217 or trade names does not constitute an official indorsement or approval of the use thereof. Destroy this report when it is no longer needed. Do not...an intergrity check of a seal than to photograph the seal’s fingerprints and to match positive/negative overlays. The seal identification time and

  9. Turbine Seal Research at NASA GRC

    Science.gov (United States)

    Proctor, Margaret P.; Steinetz, Bruce M.; Delgado, Irebert R.; Hendricks, Robert C.

    2011-01-01

    Low-leakage, long-life turbomachinery seals are important to both Space and Aeronautics Missions. (1) Increased payload capability (2) Decreased specific fuel consumption and emissions (3) Decreased direct operating costs. NASA GRC has a history of significant accomplishments and collaboration with industry and academia in seals research. NASA's unique, state-of-the-art High Temperature, High Speed Turbine Seal Test Facility is an asset to the U.S. Engine / Seal Community. Current focus is on developing experimentally validated compliant, non-contacting, high temperature seal designs, analysis, and design methodologies to enable commercialization.

  10. Strategies to prevent ventilation-associated pneumonia: the effect of cuff pressure monitoring techniques and tracheal tube type on aspiration of subglottic secretions: an in-vitro study.

    Science.gov (United States)

    Carter, Eleanor L; Duguid, Alasdair; Ercole, Ari; Matta, Basil; Burnstein, Rowan M; Veenith, Tonny

    2014-03-01

    Ventilation-associated pneumonia (VAP) is the commonest nosocomial infection in intensive care. Implementation of a VAP prevention care bundle is a proven method to reduce its incidence. The UK care bundle recommends maintenance of the tracheal tube cuff pressure at 20 to 30  cmH₂O with 4-hourly pressure checks and use of tracheal tubes with subglottic aspiration ports in patients admitted for more than 72  h. To evaluate the effects of tracheal tube type and cuff pressure monitoring technique on leakage of subglottic secretions past the tracheal tube cuff. Bench-top study. Laboratory. A model adult trachea with simulated subglottic secretions was intubated with a tracheal tube with the cuff inflated to 25  cmH₂O. Experiments were conducted using a Portex Profile Soft Seal tracheal tube with three cuff pressure monitoring strategies and using a Portex SACETT tracheal tube with intermittent cuff pressure checks. Rate of simulated secretion leakage past the tracheal tube cuff. Mean ± SD leakage of fluid past the Profile Soft Seal tracheal tube cuff was 2.25 ± 1.49  ml  min⁻¹ with no monitoring of cuff pressure, 2.98 ± 1.63  ml  min⁻¹ with intermittent cuff pressure monitoring and 3.83 ± 2.17  ml  min⁻¹ with continuous cuff pressure monitoring (P aspiration port and aspirating the simulated secretions prior to intermittent cuff pressure checks reduced the leakage rate to 0.50 ± 0.48  ml  min⁻¹ (P aspiration port. Further evaluation of medical device performance is needed in order to design more effective VAP prevention strategies.

  11. Enhanced sealing project (ESP): design, construction and monitoring of a full-scale shaft seal

    International Nuclear Information System (INIS)

    Dixon, D.; Martino, J.; Kim, C.S.; Holowick, B.; Kwong, G.; Jonsson, E.; Palonen, E.; DeCombarieu, M.

    2010-01-01

    Document available in extended abstract form only. The Enhanced Sealing Project (ESP) consists of instrumenting and monitoring a full-scale shaft seal installed to permanently close the access shaft for Atomic Energy of Canada Limited's (AECL's) Underground Research Laboratory (URL) at the intersection of an ancient low dipping thrust fault. The URL was built to provide a facility where concepts for long-term management of Canada's nuclear fuel waste in a deep geological repository could be studied. Operated since the early 1980's, this facility provided much of the technical information used in developing the deep geological repository concept submitted by AECL to the Government of Canada in 1994 and continued to provide valuable technical data after that submission. In 2003, a decision was made to discontinue operation of the URL and ultimately decommission and permanently close the underground portion of this facility. As part of the Nuclear Legacy Liability Program (NLLP) being funded by Natural Resources Canada (NRCan), facilities including the URL that are no longer part of AECL's mandate or operations are being decommissioned. Included in this work is the installation of seals at the intersection of the access shaft and ventilation raise with a deep fracture zone in order to limit the potential for mixing of deeper saline and shallower less saline groundwater. The funding available from NRCan was limited to the seal installation, with no mandate to provide any more than basic hydrological monitoring of the rock mass at a considerable distance from these seals, and so the opportunity to monitor a full-scale shaft seal similar to one for a deep geological repository would have been lost. The ESP arose from the recognition by a number of organizations that the URL closure presented a unique opportunity to monitor the evolution of a full-scale repository-type shaft seal in a very well-characterized and otherwise undisturbed rock mass. As

  12. Sealed can of spent fuel

    International Nuclear Information System (INIS)

    Suzuki, Yasuyuki.

    1976-01-01

    Object: To provide a seal plug cover with a gripping portion fitted to a canning machine and a gripping portion fitted to a gripper of the same configuration as a fuel body for handling the fuel body so as to facilitate the handling work. Structure: A sealed can comprises a vessel and a seal plug cover, said cover being substantially in the form of a bottomed cylinder, which is slipped on the vessel and air-tightly secured by a fastening bolt between it and a flange. The spent fuel body is received into the vessel together with coolant during the step of canning operation. Said seal plug cover has two gripping portions, one for opening and closing the plug cover of the canning machine as an exclusive use member, the other being in the form of a hook-shaped peripheral groove, whereby the gripping portions may be effectively used using the same gripper when the spent fuel body is transported while being received in the sealed can or when the fuel body is removed from the sealed can. (Kawakami, Y.)

  13. The bioavailability of four zinc oxide sources and zinc sulphate in broiler chickens

    OpenAIRE

    Veldkamp, T.; Diepen, van, J.T.M.; Bikker, P.

    2014-01-01

    Zinc is an essential trace element for all farm animal species. It is commonly included in animal diets as zinc oxide, zinc sulphate or organically bound zinc. Umicore Zinc Chemicals developed zinc oxide products with different mean particle sizes. Umicore Zinc Chemicals requested Wageningen UR Livestock Research to determine the bioavailability of four zinc oxide sources and zinc sulphate in broiler chickens. A precise estimate of the bioavailability of zinc sources is required both for fulf...

  14. Insecurity of imperfect quantum bit seal

    International Nuclear Information System (INIS)

    Chau, H.F.

    2006-01-01

    Quantum bit seal is a way to encode a classical bit quantum mechanically so that everyone can obtain non-zero information on the value of the bit. Moreover, such an attempt should have a high chance of being detected by an authorized verifier. Surely, a reader looks for a way to get the maximum amount of information on the sealed bit and at the same time to minimize her chance of being caught. And a verifier picks a sealing scheme that maximizes his chance of detecting any measurement of the sealed bit. Here, I report a strategy that passes all measurement detection procedures at least half of the time for all quantum bit sealing schemes. This strategy also minimizes a reader's chance of being caught under a certain scheme. In this way, I extend the result of Bechmann-Pasquinucci et al. by proving that quantum seal is insecure in the case of imperfect sealed bit recovery

  15. Factors affecting in-core dimensional stability of Zircaloy-2 calandria tubes

    International Nuclear Information System (INIS)

    Fidleris, V.; Causey, A.R.; Holt, R.A.

    1985-01-01

    In CANDU PHW reactors, the heavy water moderator is contained in a cylindrical vessel (calandria) which is penetrated by 380 horizontal fuel channel assemblies. The outer Zircaloy-2 tube of each assembly (the calandria tube) is rolled into the end shields to seal the calandria. The calandria tubes operate at ≅340 K with axial stresses that range from -10 to +40 MPa and experience fast neutron fluxes as large as 3 x 10 17 n m -2 s -1 , E > 1.0 MeV. In this environment tubes elongate and sag due to irradiation-induced creep and growth. Our understanding of these irradiation effects is based on creep, stress relaxation and irradiation growth experiments on calandria tube materials irradiated to neutron fluences of 7 x 10 25 n m -2 , E > 1.0 MeV. Both creep and growth strains decrease with the proportion of grains that have basal plane normals in the direction of testing. Cold work increases the creep rate but appears to introduce a negative component of growth in the working direction due to neutron induced stress relief that persists up to at least 7 x 10 25 n m -2 . Thermal stress relief restores the positive growth rate in the working direction. There is little effect of grain size in the range 10 TO 30 μm. This information can be used to select fabrication routes that will minimize dimensional changes of tubes during service

  16. Ultrasonic dip seal maintenance system

    International Nuclear Information System (INIS)

    Poindexter, A.M.; Ricks, H.E.

    1978-01-01

    Disclosed is a system for removing impurities from the surfaces of liquid dip seals and for wetting the metal surfaces of liquid dip seals in nuclear components. The system comprises an ultrasonic transducer that transmits ultrasonic vibrations along an ultrasonic probe to the metal and liquid surfaces of the dip seal thereby loosening and removing those impurities

  17. Reusable tamper-indicating security seal

    International Nuclear Information System (INIS)

    Ryan, M.J.

    1981-01-01

    A reusable tamper-indicating mechanical security seal for use in safeguarding nuclear material has been developed. The high-security seal displays an unpredictable, randomly selected, five-digit code each time it is used. This five digit code serves the same purpose that the serial number does for conventional non-reusable seals - a unique identifier for each use or application. The newly developed reusable seal is completely enclosed within a seamless, tamper-indicating, plastic jacket. The jacket is designed to reveal any attempts to penetrate, section or to chemically remove and replace with a counterfeit for surreptitious purposes

  18. Actively controlled shaft seals for aerospace applications

    Science.gov (United States)

    Salant, Richard F.

    1995-07-01

    This study experimentally investigates an actively controlled mechanical seal for aerospace applications. The seal of interest is a gas seal, which is considerably more compact than previous actively controlled mechanical seals that were developed for industrial use. In a mechanical seal, the radial convergence of the seal interface has a primary effect on the film thickness. Active control of the film thickness is established by controlling the radial convergence of the seal interface with a piezoelectric actuator. An actively controlled mechanical seal was initially designed and evaluated using a mathematical model. Based on these results, a seal was fabricated and tested under laboratory conditions. The seal was tested with both helium and air, at rotational speeds up to 3770 rad/sec, and at sealed pressures as high as 1.48 x 10(exp 6) Pa. The seal was operated with both manual control and with a closed-loop control system that used either the leakage rate or face temperature as the feedback. The output of the controller was the voltage applied to the piezoelectric actuator. The seal operated successfully for both short term tests (less than one hour) and for longer term tests (four hours) with a closed-loop control system. The leakage rates were typically 5-15 slm (standard liters per minute), and the face temperatures were generally maintained below 100C. When leakage rate was used as the feedback signal, the setpoint leakage rate was typically maintained within 1 slm. However, larger deviations occurred during sudden changes in sealed pressure. When face temperature was used as the feedback signal, the setpoint face temperature was generally maintained within 3 C, with larger deviations occurring when the sealed pressure changes suddenly. the experimental results were compared to the predictions from the mathematical model. The model was successful in predicting the trends in leakage rate that occurred as the balance ratio and sealed pressure changed

  19. Development of containers sealing system like part of surveillance program of the vessel in nuclear power plants; Desarrollo del sistema de sellado de contenedores como parte del programa de vigilancia de la vasija en nucleoelectricas

    Energy Technology Data Exchange (ETDEWEB)

    Romero C, J.; Hernandez C, R.; Fernandez T, F.; Rocamontes A, M.; Perez R, N. [ININ, Carretera Mexico-Toluca s/n, 52750 Ocoyoacac, Estado de Mexico (Mexico)], e-mail: jesus.romero@inin.gob.mx

    2009-10-15

    The owners of nuclear power plants should be demonstrate that the embrittlement effects by neutronic radiation do not commit the structural integrity from the pressure vessel of nuclear reactors, during conditions of routine operation and below postulate accident. For this reason, there are surveillance programs of vessels of nuclear power plants, in which are present surveillance capsules. A surveillance capsule is compound by the support, six containers for test tubes and dosimeters. The containers for test tubes are of two types: rectangular container for test tubes, Charpy V and Cylindrical Container for tension test tubes. These test tubes are subject to a same or bigger neutronic flow to that of vessel, being representative of vessel mechanical conditions. The test tubes are rehearsed to watch over the increase of embrittlement that presents the vessel. This work describes the development of welding system to seal the containers for test tubes, these should be filled with helium of ultra high purity, to a pressure of an atmosphere. In this system the welding process Gas Tungsten Arc Welding is used, a hermetic camera that allows to place the containers with three grades of freedom, a vacuum subsystem and pressure, high technology equipment's like: power source with integrated computer, arc starter of high frequency, helium flow controller, among others. Finally, the advances in the inspection system for the qualification of sealing system are mentioned, system that should measure the internal pressure of containers and the helium purity inside these. (Author)

  20. Development and high temperature sealing performance study of double sealing flange

    International Nuclear Information System (INIS)

    Zhang Qinhua; Fu Yuan; Xie Leidong; Li Zhong; Tang Zhongfeng

    2013-01-01

    Background: Flange is an important component used in the connection between pipes or between pipe and equipment. It is widely used in mechanical industry, petrochemical industry and nuclear industry. Ordinary flange could be oxidized oi corroded under high temperature and strong corrosion condition, which leads to flange's failure. Purpose: The aim is to design and validate the double sealing flange which could be used in high temperature and strong corrosion condition stably and supplied as a reliable detachable connection for petrochemical industry and nuclear industry under high temperature and strong corrosion environment. Methods: New flange is designed using flexible graphite spiral wound gaskets and C style metal ring double sealing structure. The unique protection gas design ensures the graphite spiral wound gasket used in high temperature reliably. Test bed is built to verify the stability of the flange. Results: Pressure reducing of graphite spiral wound gasket is only 0.01 MPa at 750℃, 0.7 MPa for 43 h, there is not obvious oxidation phenomenon at the same time. The leakage rate of metal C sealing ring is 11.51×10 -4 atm cc/s, and the metal C ring sealing's performance meets the engineering requirements. Conclusion: The leakage rate of double sealing flange is almost zero under 0.7 MPa at 750℃, which meets the engineering requirements. It avoids oxidizing at high temperature and corroding under strong corrosion condition. (authors)

  1. Steam Turbine Flow Path Seals (a Review)

    Science.gov (United States)

    Neuimin, V. M.

    2018-03-01

    Various types of shroud, diaphragm, and end seals preventing idle leak of working steam are installed in the flow paths of steam turbine cylinders for improving their efficiency. Widely known labyrinth seals are most extensively used in the Russian turbine construction industry. The category of labyrinth seals also includes seals with honeycomb inserts. The developers of seals with honeycomb inserts state that the use of such seals makes it possible to achieve certain gain due to smaller leaks of working fluid and more reliable operation of the system under the conditions in which the rotor rotating parts may rub against the stator elements. However, a positive effect can only be achieved if the optimal design parameters of the honeycomb structure are fulfilled with due regard to the specific features of its manufacturing technology and provided that this structure is applied in a goal-seeking manner in the seals of steam and gas turbines and compressors without degrading their vibration stability. Calculated and preliminary assessments made by experts testify that the replacement of conventional labyrinth seals by seals with honeycomb inserts alone, due to which the radial gaps in the shroud seal can be decreased from 1.5 to 0.5 mm, allows the turbine cylinder efficiency to be increased at the initial stage by approximately 1% with the corresponding gain in the turbine set power output. The use of rectangular-cellular seals may result, according to estimates made by their developers, in a further improvement of turbine efficiency by 0.5-1.0%. The labor input required to fabricate such seals is six to eight times smaller than that to fabricate labyrinth seals with honeycomb inserts. Recent years have seen the turbine construction companies of the United States and Germany advertising the use of abradable (sealing) coatings (borrowed from the gas turbine construction technology) in the turbine designs instead of labyrinth seals. The most efficient performance of

  2. Zinc electrode - its behaviour in the nickel oxide-zinc accumulator

    Energy Technology Data Exchange (ETDEWEB)

    1984-01-01

    Certain aspects of zinc electrode reaction and behavior are investigated in view of their application to batteries. The properties of the zinc electrode in a battery system are discussed, emphasizing porous structure. Shape change is emphasized as the most important factor leading to limited battery cycle life. It is shown that two existing models of shape change based on electroosmosis and current distribution are unable to consistently describe observed phenomena. The first stages of electrocrystallization are studied and the surface reactions between the silver substrate and the deposited zinc layer are investigated. The reaction mechanism of zinc and amalgamated zinc in an alkaline electrolyte is addressed, and the batter system is studied to obtain information on cycling behavior and on the shape change phenomenon. The effect on cycle behavior of diferent amalgamation techniques of the zinc electrode and several additives is addressed. Impedance measurements on zinc electrodes are considered, and battery behavior is correlated with changes in the zinc electrode during cycling. 193 references.

  3. The bioavailability of four zinc oxide sources and zinc sulphate in broiler chickens

    NARCIS (Netherlands)

    Veldkamp, T.; Diepen, van J.T.M.; Bikker, P.

    2014-01-01

    Zinc is an essential trace element for all farm animal species. It is commonly included in animal diets as zinc oxide, zinc sulphate or organically bound zinc. Umicore Zinc Chemicals developed zinc oxide products with different mean particle sizes. Umicore Zinc Chemicals requested Wageningen UR

  4. Rehabilitation of Permeable Breakwaters and Jetties by Void Sealing: Summary Report. Repair, Evaluation, Maintenance, and Rehabilitation Research Program

    Science.gov (United States)

    1990-10-01

    able sealing material that has promising characteristics for coastal engineer- ing applications. Microfine Cement, a company which markets ultrafine...cement, claims the product can penetrate fine sand and is strong and durable with a 4- to 5-hr set tine. Fifty percent of Microfine Cement’s...sealant. The casing can be pierced at any selected point by firing an explosive-impelled projectile from a device lowered into the casing. d. Tubes A

  5. Appropriate zinc addition management into PWR primary coolant after the plant long-term maintenance

    International Nuclear Information System (INIS)

    Hirose, Atsushi; Matsui, Ryo; Imamura, Haruki; Takahashi, Akira; Shimizu, Yuichi; Kogawa, Noritaka; Nagamine, Kunitaka

    2014-01-01

    Zinc addition into the PWR primary coolant is known as an effective method to reduce the radioactivity build up. The reduction effect has been confirmed by actual plant experience of the Genkai Nuclear Power Plant Unit 1 to 4 and the Sendai Nuclear Power Plant Unit 1 to 2 which are operated by Kyushu Electric Power Co. in Japan. Zinc addition is suspended at shut-down, and is resumed after heat up or arrival at full power. In usual maintenance, the period when zinc addition is not applied is short; thus it is considered that suspension of zinc addition does not have practical influence on the corrosion and the radioactivity buildup in the oxide layer of surface for the primary equipment and piping. On the other hand, in case the maintenance period is much longer, the new oxide which does not contain zinc has grown, and then the structure of the oxide layer may be changed. Therefore, it is considered that zinc addition suspension in long-term period has possibilities to deteriorate the dose reduction effect. In order to verify the effect of long-term suspension of zinc addition upon oxide layer, the lab experiment was carried out using TT690 alloy which is the constitution material of the steam generator tubes under the conditions of long-term and the subsequent resuming operations. After the experiment, the specimens were analyzed by IMA and chemical analysis. These measurement results suggest the difference of the oxide layer is little or none between long-term suspension of zinc addition and short-term suspension of zinc suspension. Hence it is considered that influence of long-term maintenance on the oxide layer is small. Furthermore, in this study, in order to evaluate the influence of the suspension of zinc addition in the operation period, specimens of oxide film formed with zinc were carried out the corrosion test in the simulated RCS condition without zinc. These measurement results indicate the effect of reduction of the activity build up will become less

  6. Negative pressure pulmonary oedema following use of ProSeal LMA

    Directory of Open Access Journals (Sweden)

    Richa Jain

    2013-01-01

    Full Text Available Negative pressure pulmonary oedema (NPPO is a life threatening condition, manifested due to upper airway obstruction in a spontaneously breathing patient. Upper airway obstruction caused by classic laryngeal mask airway (cLMA and ProSeal laryngeal mask airway (PLMA has been reported, and NPPO has also been reported following the use of cLMA. Search of literature did not confirm NPPO following the use of PLMA. We encountered a female patient of NPPO scheduled for incision and drainage of an abscess who had signs of airway obstruction following PLMA insertion. Multiple attempts were made to get patent airway without success. PLMA was replaced with endotracheal tube following which pink frothy secretion appeared in breathing circuit. Patient was managed successfully with ICU care.

  7. Concentration differences between serum and plasma of the elements cobalt, iron, mercury, rubidium, selenium and zinc determined by neutron activation analysis

    International Nuclear Information System (INIS)

    Kasperek, K.; Kiem, J.; Iyengar, G.V.; Feinendegen, L.E.

    1981-01-01

    The differences in concentrations of cesium, cobalt, iron, mercury, rubidium, selenium and zinc between serum and plasma were examined with the aid of instrumental neutron activation analysis. Eighty serum and plasma samples obtained from 13 donors were compared. Serum was prepared in plastic tubes immediately after clotting, and plasma was separated with heparin as anticoagulant. No significant differences in the concentrations of cesium, cobalt, mercury and selenium were observed. However, the concentrations of iron, rubidium and zinc were significantly higher in serum than in plasma. The average differences were 322, 12 and 20 ng/ml for iron, rubidium and zinc, respectively. The average differences found for cesium, rubidium and zinc were far below that which can be expected from a complete, or considerable release of these elements from platelets which aggregate or disintegrate during the clotting process in preparing serum. (orig.)

  8. SEAL FOR HIGH SPEED CENTRIFUGE

    Science.gov (United States)

    Skarstrom, C.W.

    1957-12-17

    A seal is described for a high speed centrifuge wherein the centrifugal force of rotation acts on the gasket to form a tight seal. The cylindrical rotating bowl of the centrifuge contains a closure member resting on a shoulder in the bowl wall having a lower surface containing bands of gasket material, parallel and adjacent to the cylinder wall. As the centrifuge speed increases, centrifugal force acts on the bands of gasket material forcing them in to a sealing contact against the cylinder wall. This arrangememt forms a simple and effective seal for high speed centrifuges, replacing more costly methods such as welding a closure in place.

  9. The cool seal system: a practical solution to the shaft seal problem and heat related complications with implantable rotary blood pumps.

    Science.gov (United States)

    Yamazaki, K; Mori, T; Tomioka, J; Litwak, P; Antaki, J F; Tagusari, O; Koyanagi, H; Griffith, B P; Kormos, R L

    1997-01-01

    A critical issue facing the development of an implantable, rotary blood pump is the maintenance of an effective seal at the rotating shaft. Mechanical seals are the most versatile type of seal in wide industrial applications. However, in a rotary blood pump, typical seal life is much shorter than required for chronic support. Seal failure is related to adhesion and aggregation of heat denatured blood proteins that diffuse into the lubricating film between seal faces. Among the blood proteins, fibrinogen plays an important role due to its strong propensity for adhesion and low transition temperature (approximately 50 degrees C). Once exposed to temperature exceeding 50 degrees C, fibrinogen molecules fuse together by multi-attachment between heat denatured D-domains. This quasi-polymerized fibrin increases the frictional heat, which proliferates the process into seal failure. If the temperature of the seal faces is maintained well below 50 degrees C, a mechanical seal would not fail in blood. Based on this "Cool-Seal" concept, we developed a miniature mechanical seal made of highly thermally conductive material (SiC), combined with a recirculating purge system. A large supply of purge fluid is recirculated behind the seal face to augment convective heat transfer to maintain the seal temperature below 40 degrees C. It also cools all heat generating pump parts (motor coil, bearing, seal). The purge consumption has been optimized to virtually nil (seal system has now been incorporated into our intraventricular axial flow blood pump (IVAP) and newly designed centrifugal pump. Ongoing in vivo evaluation of these systems has demonstrated good seal integrity for more than 160 days. The Cool-Seal system can be applied to any type of rotary blood pump (axial, diagonal, centrifugal, etc.) and offers a practical solution to the shaft seal problem and heat related complications, which currently limit the use of implantable rotary blood pumps.

  10. Miniature magnetic fluid seal working in liquid environments

    Energy Technology Data Exchange (ETDEWEB)

    Mitamura, Yoshinori, E-mail: ymitamura@par.odn.ne.jp [Graduate School of Information Science and Technology, Hokkaido University, Sapporo 060-0814 (Japan); Durst, Christopher A., E-mail: chris@procyrion.com [Procyrion, Inc., Houston, TX 77027 (United States)

    2017-06-01

    This study was carried out to develop a miniature magnetic fluid (MF) seal working in a liquid environment. The miniature MF seal is intended for use in a catheter blood pump. The requirements for the MF seal included a size of less than Ø4×4.5 mm, shaft diameter of 1 mm, sealing pressure of 200 mmHg, shaft speed of up to 40000 rpm, and life of one month. The miniature MF seal was composed of an NdFeB magnet (Ø4×Ø2×1) sandwiched between two pole pieces (Ø4×Ø1.1×0.5). A shield (Ø4×Ø1.2×1.5) was placed on the pole piece facing the liquid to minimize the influence of pump flow on the MF. The seal was installed on a Ø1 shaft. A seal was formed by injecting MF (Ms: 47.8 kA/m and η: 0.5 Pa·sec) into the gap between the pole pieces and the shaft. Total volume of the MF seal was 44 μL. A sealing pressure of 370 mmHg was obtained at motor speeds of 0-40,000 rpm. The seal remained perfect for 10 days in saline under the condition of a pump flow of 1.5 L/min (The test was terminated in accordance with plans). The seal remained intact after ethylene oxide sterilization during which the seal was exposed to high pressures. In conclusion, the newly developed MF seal will be useful for a catheter pump. - Highlights: • A miniature magnetic fluid seal working in a liquid environment was developed. • The seal can be installed on Ø1 mm shaft and can seal against 370 mmHg at 40000 rpm. • The magnetic fluid seal will be useful for a catheter blood pump.

  11. Design of sealing arrangements for development of leak tight articulated manipulator for waste management and reprocessing plants

    International Nuclear Information System (INIS)

    Patil, Satish B.; Mudaiya, Avinash K.

    2016-01-01

    As a part of development of Remote handling equipment and gadgets, Leak tight Articulated Manipulator (ARTM) has been developed for shielded facilities of Nuclear Recycle Plant. The ARTM is a Master Slave Manipulator having 8 Kg Payload capacity and most suitable for shielded sampling cubicles of Waste Management plants and dilution hot cells of Reprocessing plants. All the motions and forces are transmitted from Master to slave arm through the mechanical linkages, which are housed inside the wall tube. The mechanical linkages and wall tube run across the shielded wall. The applications involving seal tightness of the glove boxes and dilution hot cells intend to use all the accessories including MSMs to be leak tight. During the design of leak tight ARTM, all the potential leak paths through the components of existing ARTM were examined critically and static and dynamic seals were designed based on the geometry and requirement of particular leak path. A leak proof testing set up was fabricated for evaluating the leak rates across the manipulator contemplating the actual operating conditions. The manipulator was subjected to the Friction, Rigidity and Leak tests. The results of the tests are satisfactory and as per the International standards available. The leak rates measured for different manipulators were in the range of 0.05 to 0.1 % of air volume/hr @ 200 mm of water columndifferential negative pressure. (author)

  12. Design analysis of a self-acting spiral-groove ring seal for counter-rotating shafts. [o ring seals

    Science.gov (United States)

    Dirusso, E.

    1983-01-01

    A self-acting spiral groove inter-shaft ring seal of nominal 16.33 cm (6.43 in.) diameter for sealing fan bleed air between counter rotating shafts in advanced turbofan engines was analyzed. The analysis focused on the lift force characteristics of the spiral grooves. A NASA Lewis developed computer program for predicting the performance of gas lubricated face seals was used to optimize the spiral groove geometry to produce maximum lift force. Load capacity curves (lift force as function of film thickness) were generated for four advanced turbofan engine operating conditions at relative seal speeds ranging from 17,850 to 29,800 rpm, sealed air pressures from 6 to 42 N/sq cm (9 to 60 psi) absolute and temperatures from 95 to 327 C (203 to 620 F). The relative seal sliding speed range was 152 to 255 m/sec (500 to 836 ft/sec). The analysis showed that the spiral grooves are capable of producing sufficient lift force such that the ring seal will operate in a noncontacting mode over the operating range of typical advanced turbofan engines.

  13. Effect of consuming zinc-fortified bread on serum zinc and iron status of zinc-deficient women: A double blind, randomized clinical trial

    Directory of Open Access Journals (Sweden)

    Akbar Badii

    2012-01-01

    Full Text Available After iron deficiency, zinc deficiency is the major micronutrient deficiency in developing countries, and staple food fortification is an effective strategy to prevent and improve it among at-risk-populations. No action has been taken to reduce zinc deficiency via flour fortification so far in Iran, and little is known about the influence of zinc fortification of flour on serum zinc and the iron status, and also about the optimum and effective amount of zinc compound that is used in food fortification. The objective of this study is to evaluate the influence of consuming zinc-fortified breads on the zinc and iron status in the blood serum. In this study, three types of bread were prepared from non-fortified and fortified flours, with 50 and 100 ppm elemental zinc in the form of sulfate. Eighty zinc-deficient women aged 19 to 49 years were randomly assigned to three groups; The volunteers received, daily, (1 a non-fortified bread, (2 a high-zinc bread, and (3 a low-zinc bread for one month. Serum zinc and iron were measured by Atomic Absorption before and after the study. Results showed a significant increase in serum zinc and iron levels in all groups (p 0.05. Absorption of zinc and iron in the group that consumed high-zinc bread was significantly greater than that in the group that received low-zinc bread (p < 0.01. It was concluded that fortification of flour with 50-100 ppm zinc was an effective way to achieve adequate zinc intake and absorption in zinc-deficient people. It also appeared that consuming zinc-fortified bread improved iron absorption.

  14. Seal Apparatus and Methods to Manufacture Thereof

    Science.gov (United States)

    Richard, James A. (Inventor)

    2013-01-01

    In some implementations, apparatus and methods are provided through which a dynamic cryogenic seal is manufactured. In some implementations, the seal includes a retainer and a spring-seal assembly, the assembly being comprised of a main spring housing and fluorine-containing polymer seals. In some implementations, either a radial seal, or an axial (or "piston seal") is provided. In some implementations, methods of manufacturing the dynamic cryogenic seal are also provided. In some implementations, the methods include assembling the components while either heated or cooled, taking advantage of thermal expansion and contraction, such that there is a strong interference fit between the components at room temperature. In some implementations, this process ensures that the weaker fluorine-containing polymer seal is forced to expand and contract with the stronger retainer and spring and is under constant preload. In some implementations, the fluorine-containing polymer is therefore fluidized and retained, and can not lift off.

  15. A dynamic analysis of rotary combustion engine seals

    Science.gov (United States)

    Knoll, J.; Vilmann, C. R.; Schock, H. J.; Stumpf, R. P.

    1984-01-01

    Real time work cell pressures are incorporated into a dynamic analysis of the gas sealing grid in Rotary Combustion Engines. The analysis which utilizes only first principal concepts accounts for apex seal separation from the crochoidal bore, apex seal shifting between the sides of its restraining channel, and apex seal rotation within the restraining channel. The results predict that apex seals do separate from the trochoidal bore and shift between the sides of their channels. The results also show that these two motions are regularly initiated by a seal rotation. The predicted motion of the apex seals compares favorably with experimental results. Frictional losses associated with the sealing grid are also calculated and compare well with measurements obtained in a similar engine. A comparison of frictional losses when using steel and carbon apex seals has also been made as well as friction losses for single and dual side sealing.

  16. Mechanical seal having a double-tier mating ring

    Science.gov (United States)

    Khonsari, Michael M.; Somanchi, Anoop K.

    2005-09-13

    An apparatus and method to enhance the overall performance of mechanical seals in one of the following ways: by reducing seal face wear, by reducing the contact surface temperature, or by increasing the life span of mechanical seals. The apparatus is a mechanical seal (e.g., single mechanical seals, double mechanical seals, tandem mechanical seals, bellows, pusher mechanical seals, and all types of rotating and reciprocating machines) comprising a rotating ring and a double-tier mating ring. In a preferred embodiment, the double-tier mating ring comprises a first and a second stationary ring that together form an agitation-inducing, guided flow channel to allow for the removal of heat generated at the seal face of the mating ring by channeling a coolant entering the mating ring to a position adjacent to and in close proximity with the interior surface area of the seal face of the mating ring.

  17. Development of the seal for nuclear material

    International Nuclear Information System (INIS)

    Lu Feng; Lu Zhao; Zhao Yonggang; Zhang Qixin; Xiao Xuefu

    2000-01-01

    Two kinds of double cap metallic seal and an adhesive seal are developed for the purpose of the accounting for and control of nuclear material. Two kinds of double cap metallic seal are made of stainless steel and copper, respectively and the self-locked technique is used. The number and the random pattern are carved out side and in side of a cap, respectively, for the seal. The random pattern carved inside of a cap for seal is taken a picture using numeral camera and memorized in computer. Special software is developed for verification of the random pattern memorized in computer. The adhesive seal is made of special adhesive paper for purpose of security, and a special pattern guarded against falsification is printed on seal paper using ultraviolet fluorescent light technique

  18. Innovation to reality for improved pump seal performance

    International Nuclear Information System (INIS)

    Wong, W.; Eyvindson, A.; Rhodes, D.B.

    2003-01-01

    'Full-Text:' The nuclear industry requires reliable pump seals. Extended operating conditions for aging plants (i.e., low pressure starts, pressure and temperature transients) and increasing demands from new plants (larger sizes, higher speeds) are pushing the operating envelope for seals. This means that many seals that were previously considered adequate are now requiring increased attention and care. Operating utilities have taken different approaches to addressing their existing, or emerging, seal problems. Primary concerns include maintenance practices, seal design, and monitoring capabilities, as well as operating conditions, transients, pump and motor design. Success in this area requires ongoing dialogue among the station operators, pump manufacturers and seal designers. Regardless of the design, the basic requirement in CANDU is a reliable seal lifetime exceeding 5 years. This paper describes AECL's efforts to meet this requirement through an ongoing program of research and development in seal technology. Current work includes rigorous testing and evaluation of new seal materials and coatings to maximize seal stability and minimize friction and wear (i.e., pressure/temperature transients produce unpredictable shaft movement that can significantly alter face deflections affecting leak rates and seal stability, and sometimes cause the seal to hang-up and de-stage). Also required is a practical method for on-line monitoring of the condition of the seal, whether it is newly installed or after several years of reliable performance. This provides crucial information for inventory, maintenance and outage planning. While new concepts may look good on paper, it is only after they have been demonstrated under fully representative station operating conditions that they can truly be considered ready for field use. AECL CAN-seals lead the nuclear industry in reliability and seal life. They effectively save operators millions of dollars in outage time and person

  19. Diaphragm flange and method for lowering particle beam impedance at connected beam tubes of a particle accelerator

    Energy Technology Data Exchange (ETDEWEB)

    Biallas, George Herman

    2017-07-04

    A diaphragm flange for connecting the tubes in a particle accelerator while minimizing beamline impedance. The diaphragm flange includes an outer flange and a thin diaphragm integral with the outer flange. Bolt holes in the outer flange provide a means for bolting the diaphragm flange to an adjacent flange or beam tube having a mating bolt-hole pattern. The diaphragm flange includes a first surface for connection to the tube of a particle accelerator beamline and a second surface for connection to a CF flange. The second surface includes a recessed surface therein and a knife-edge on the recessed surface. The diaphragm includes a thickness that enables flexing of the integral diaphragm during assembly of beamline components. The knife-edge enables compression of a soft metal gasket to provide a leak-tight seal.

  20. Troubleshooting ProSeal LMA

    Directory of Open Access Journals (Sweden)

    Bimla Sharma

    2009-01-01

    Full Text Available Supraglottic devices have changed the face of the airway management. These devices have contributed in a big way in airway management especially, in the difficult airway scenario significantly decreasing the pharyngolaryngeal morbidity. There is a plethora of these devices, which has been well matched by their wider acceptance in clinical practice. ProSeal laryngeal mask airway (PLMA is one such frequently used device employed for spontaneous as well as controlled ventilation. However, the use of PLMAat tunes maybe associated with certain problems. Some of the problems related with its use are unique while others are akin to the classic laryngeal mask airway (eLMA. However, expertise is needed for its safe and judicious use, correct placement, recognition and management of its various malpositions and complications. The present article describes the tests employed for proper confirmation of placementto assess the ventilatooy and the drain tube functions of the mask, diagnosis of various malpositions and the management of these aspects. All these areas have been highlighted under the heading of troubleshooting PLMA. Many problems can be solved by proper patient and procedure selection, maintaining adequate depth of anaesthesia, diagnosis and management of malpositions. Proper fixation of the device and monitoring cuff pressure intraopera-tively may bring down the incidence of airway morbidity.

  1. Relative flotation response of zinc sulfide: Mineral and precipitate

    Energy Technology Data Exchange (ETDEWEB)

    Rao, S.R.; Finch, J.A. [McGill Univ., Montreal, Quebec (Canada). Dept. of Mining and Metallurgical Engineering; Zhou, Z.; Xu, Z. [Univ. of Alberta, Edmonton, Alberta (Canada). Dept. of Chemical and Materials Engineering

    1998-04-01

    Flotation continues to extend to nonmineral applications, including recycling of materials, soil remediation, and effluent treatment. A study has been conducted to compare the floatability of fine zinc sulfide (ZnS) precipitates and sphalerite particles. The floatability of the precipitates was significantly poorer compared to sphalerite particles when xanthate was used as the collector. The floatability was improved by using dodecylamine as the collector, and the difference in floatability between the precipitates was further improved significantly by incorporating a hydrodynamic cavitation tube in a conventional (mechanical) flotation cell. The improved kinetics was attributed to in-situ gas nucleation on the precipitates.

  2. Innovative Seals for Solid Oxide Fuel Cells (SOFC)

    Energy Technology Data Exchange (ETDEWEB)

    Singh, Raj

    2008-06-30

    A functioning SOFC requires different type of seals such as metal-metal, metal-ceramic, and ceramic-ceramic. These seals must function at high temperatures between 600--900{sup o}C and in oxidizing and reducing environments of the fuels and air. Among the different type of seals, the metal-metal seals can be readily fabricated using metal joining, soldering, and brazing techniques. However, the metal-ceramic and ceramic-ceramic seals require significant research and development because the brittle nature of ceramics/glasses can lead to fracture and loss of seal integrity and functionality. Consequently, any seals involving ceramics/glasses require a significant attention and technology development for reliable SOFC operation. This final report is prepared to describe the progress made in the program on the needs, approaches, and performance of high temperature seals for SOFC. In particular, a new concept of self-healing glass seals is pursued for making seals between metal-ceramic material combinations, including some with a significant expansion mismatch.

  3. Production of zinc pellets

    Science.gov (United States)

    Cooper, J.F.

    1996-11-26

    Uniform zinc pellets are formed for use in batteries having a stationary or moving slurry zinc particle electrode. The process involves the cathodic deposition of zinc in a finely divided morphology from battery reaction product onto a non-adhering electrode substrate. The mossy zinc is removed from the electrode substrate by the action of gravity, entrainment in a flowing electrolyte, or by mechanical action. The finely divided zinc particles are collected and pressed into pellets by a mechanical device such as an extruder, a roller and chopper, or a punch and die. The pure zinc pellets are returned to the zinc battery in a pumped slurry and have uniform size, density and reactivity. Applications include zinc-air fuel batteries, zinc-ferricyanide storage batteries, and zinc-nickel-oxide secondary batteries. 6 figs.

  4. 21 CFR 864.9750 - Heat-sealing device.

    Science.gov (United States)

    2010-04-01

    ... and Blood Products § 864.9750 Heat-sealing device. (a) Identification. A heat-sealing device is a device intended for medical purposes that uses heat to seal plastic bags containing blood or blood... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Heat-sealing device. 864.9750 Section 864.9750...

  5. Refurbishing the seals of the H2S compressors in the isotopic exchange installations at the Heavy Water Reprocessing Plant. Technical solutions for replacing liquid seals by dry seals

    International Nuclear Information System (INIS)

    Panait; Adrian; Serban, Viorel; Androne, Marian; Florea, Ioana; Ciocan, George; State, Elena

    2004-01-01

    An analysis of the present sealing system in the H 2 S compressors showed that the risk of accidental hydrogen sulfide escape into the atmosphere is high in case of a seal oil pressure loss. At the same time there exist drawbacks occurring even in normal regime of functioning among which one can mention: - relatively high losses of oil occur, part of the oil being carried away by the compressors and released into the isotopic exchange columns where the water counter current flow produces a foaming that reduces the column processing capacity; - part of the sealing oil leaks reaches the final product, the heavy water, where from it must be removed by chemical procedures; - the installations adjacent to the sealing system are relatively sophisticated and require relatively high expenses for exploitation and maintenance. The classical sealing systems using sealing rings, sleeves, labyrinths, etc, cannot be used since their safe working range is exceeded due to either driving shaft rotational speed, or to the increase of its diameter, or else to an increase of the speed of motion of moving parts relative to the fix parts. The sealing systems with magnetic liquids are rather sophisticated and expensive while in case of electric supply loss they are completely unsafe, because their sealing capacity vanishes. The materials used for sealing gaskets limit their application only to the cases when the relative motion of the moving pieces is low or vanishing what happens only at shut down or failure situations. To prevent these drawbacks of the present seal system in the H 2 S compressors of the isotopic exchange columns and having in view the limitations of the currently used sealing systems a new system of sealing was conceived and designed on the basis of the patent titled 'Sealing Installation and Procedure' recorded by OSIM under No. A/0315/10.04.2003. The new system can be built as a single or double stage each of them having in turn a dynamic and a static sub-stage. The

  6. Cysteine-rich intestinal protein binds zinc during transmucosal zinc transport

    International Nuclear Information System (INIS)

    Hempe, J.M.; Cousins, R.J.

    1991-01-01

    The mechanism of zinc absorption has not been delineated, but kinetic studies show that both passive and carrier-mediated processes are involved. The authors have identified a low molecular mass zinc-binding protein in the soluble fraction of rat intestinal mucosa that could function as an intracellular zinc carrier. The protein was not detected in liver or pancreas, suggesting a role specific to the intestine. The protein binds zinc during transmucosal zinc transport and shows signs of saturation at higher luminal zinc concentrations, characteristics consistent with a role in carrier-mediated zinc absorption. Microsequence analysis of the protein purified by gel-filtration HPCL and SDS/PAGE showed complete identity within the first 41 N-terminal amino acids with the deduced protein sequence of cysteine-rich intestinal protein. These investigators showed that the gene for this protein is developmentally regulated in neonates during the suckling period, conserved in many vertebrate species, and predominantly expressed in the small intestine. Cysteine-rich intestinal protein contains a recently identified conserved sequence of histidine and cysteine residues, the LIM motif, which our results suggest confers metal-binding properties that are important for zinc transport and/or functions of this micronutrient

  7. Improved cryogenic shaft seals

    Science.gov (United States)

    Gillon, W. A., Jr.; Tellier, G. F.

    1976-01-01

    Seals are designed for use with liquid propellant ball valves at temperatures ranging from -400 F to 130 F and 8,000 psig. Seals are capable of sustaining 90 degree rotation, with substantial amount of lateral and axial play, caused by large pressure loads and differential thermal contraction.

  8. Face-Sealing Butterfly Valve

    Science.gov (United States)

    Tervo, John N.

    1992-01-01

    Valve plate made to translate as well as rotate. Valve opened and closed by turning shaft and lever. Interactions among lever, spring, valve plate, and face seal cause plate to undergo combination of translation and rotation so valve plate clears seal during parts of opening and closing motions.

  9. Zinc Signals and Immunity.

    Science.gov (United States)

    Maywald, Martina; Wessels, Inga; Rink, Lothar

    2017-10-24

    Zinc homeostasis is crucial for an adequate function of the immune system. Zinc deficiency as well as zinc excess result in severe disturbances in immune cell numbers and activities, which can result in increased susceptibility to infections and development of especially inflammatory diseases. This review focuses on the role of zinc in regulating intracellular signaling pathways in innate as well as adaptive immune cells. Main underlying molecular mechanisms and targets affected by altered zinc homeostasis, including kinases, caspases, phosphatases, and phosphodiesterases, will be highlighted in this article. In addition, the interplay of zinc homeostasis and the redox metabolism in affecting intracellular signaling will be emphasized. Key signaling pathways will be described in detail for the different cell types of the immune system. In this, effects of fast zinc flux, taking place within a few seconds to minutes will be distinguish from slower types of zinc signals, also designated as "zinc waves", and late homeostatic zinc signals regarding prolonged changes in intracellular zinc.

  10. Spray sealing: A breakthrough in integral fuel tank sealing technology

    Science.gov (United States)

    Richardson, Martin D.; Zadarnowski, J. H.

    1989-11-01

    In a continuing effort to increase readiness, a new approach to sealing integral fuel tanks is being developed. The technique seals potential leak sources by spraying elastomeric materials inside the tank cavity. Laboratory evaluations project an increase in aircraft supportability and reliability, an improved maintainability, decreasing acquisition and life cycle costs. Increased usable fuel volume and lower weight than conventional bladders improve performance. Concept feasibility was demonstrated on sub-scale aircraft fuel tanks. Materials were selected by testing sprayable elastomers in a fuel tank environment. Chemical stability, mechanical properties, and dynamic durability of the elastomer are being evaluated at the laboratory level and in sub-scale and full scale aircraft component fatigue tests. The self sealing capability of sprayable materials is also under development. Ballistic tests show an improved aircraft survivability, due in part to the elastomer's mechanical properties and its ability to damp vibrations. New application equipment, system removal, and repair methods are being investigated.

  11. Magnetically Actuated Seal, Phase I

    Data.gov (United States)

    National Aeronautics and Space Administration — FTT proposes development of a magnetically actuated dynamic seal. Dynamic seals are used throughout the turbopump in high-performance, pump-fed, liquid rocket...

  12. Magnetically Actuated Seal, Phase II

    Data.gov (United States)

    National Aeronautics and Space Administration — FTT proposes development of a magnetically actuated dynamic seal. Dynamic seals are used throughout the turbopump in high-performance, pump-fed, liquid rocket...

  13. Zinc in Cellular Regulation: The Nature and Significance of "Zinc Signals".

    Science.gov (United States)

    Maret, Wolfgang

    2017-10-31

    In the last decade, we witnessed discoveries that established Zn 2+ as a second major signalling metal ion in the transmission of information within cells and in communication between cells. Together with Ca 2+ and Mg 2+ , Zn 2+ covers biological regulation with redox-inert metal ions over many orders of magnitude in concentrations. The regulatory functions of zinc ions, together with their functions as a cofactor in about three thousand zinc metalloproteins, impact virtually all aspects of cell biology. This article attempts to define the regulatory functions of zinc ions, and focuses on the nature of zinc signals and zinc signalling in pathways where zinc ions are either extracellular stimuli or intracellular messengers. These pathways interact with Ca 2+ , redox, and phosphorylation signalling. The regulatory functions of zinc require a complex system of precise homeostatic control for transients, subcellular distribution and traffic, organellar homeostasis, and vesicular storage and exocytosis of zinc ions.

  14. Effect of Consuming Zinc-fortified Bread on Serum Zinc and Iron Status of Zinc-deficient Women: A Double Blind, Randomized Clinical Trial.

    Science.gov (United States)

    Badii, Akbar; Nekouei, Niloufar; Fazilati, Mohammad; Shahedi, Mohammad; Badiei, Sajad

    2012-03-01

    After iron deficiency, zinc deficiency is the major micronutrient deficiency in developing countries, and staple food fortification is an effective strategy to prevent and improve it among at-risk-populations. No action has been taken to reduce zinc deficiency via flour fortification so far in Iran, and little is known about the influence of zinc fortification of flour on serum zinc and the iron status, and also about the optimum and effective amount of zinc compound that is used in food fortification. The objective of this study is to evaluate the influence of consuming zinc-fortified breads on the zinc and iron status in the blood serum. In this study, three types of bread were prepared from non-fortified and fortified flours, with 50 and 100 ppm elemental zinc in the form of sulfate. Eighty zinc-deficient women aged 19 to 49 years were randomly assigned to three groups; The volunteers received, daily, (1) a non-fortified bread, (2) a high-zinc bread, and (3) a low-zinc bread for one month. Serum zinc and iron were measured by Atomic Absorption before and after the study. Results showed a significant increase in serum zinc and iron levels in all groups (p 0.05). Absorption of zinc and iron in the group that consumed high-zinc bread was significantly greater than that in the group that received low-zinc bread (p bread improved iron absorption.

  15. Mechanical design of ceramic beam tube braze joints for NOvA kicker magnets

    Energy Technology Data Exchange (ETDEWEB)

    Ader, C.R.; Reilly, R.E.; Wilson, J.H.; /Fermilab

    2010-05-01

    The NO?A Experiment will construct a detector optimized for electron neutrino detection in the existing NuMI neutrino beam. The NuMI beam line is capable of operating at 400 kW of primary beam power and the upgrade will allow up to 700 kW. Ceramic beam tubes are utilized in numerous kicker magnets in different accelerator rings at Fermi National Accelerator Laboratory. Kovar flanges are brazed onto each beam tube end, since kovar and high alumina ceramic have similar expansion curves. The tube, kovar flange, end piece, and braze foil alloy brazing material are stacked in the furnace and then brazed. The most challenging aspect of fabricating kicker magnets in recent years have been making hermetic vacuum seals on the braze joints between the ceramic and flange. Numerous process variables can influence the robustness of conventional metal/ceramic brazing processes. The ceramic-filler metal interface is normally the weak layer when failure does not occur within the ceramic. Differences between active brazing filler metal and the moly-manganese process will be discussed along with the applicable results of these techniques used for Fermilab production kicker tubes.

  16. Guide to optimized replacement of equipment seals

    International Nuclear Information System (INIS)

    Gleason, J.F.

    1990-03-01

    A reevaluation of current scheduled replacement intervals of polymeric seals in plant equipment can achieve significant benefits. Information is provided which has the potential for increasing replacement intervals based on better information on how seals have performed through unique nuclear industry tests to qualify equipment, improved elastomers and increased knowledge of the failure mechanisms and related performance. The research was performed by reviewing applications of elastomeric seals in nuclear plants and practice associated with defining seal replacement intervals in the nuclear power and other industries. Performance indicators and how they predict degradation of seals were evaluated. Guidelines and a flow chart for reevaluating seal replacement intervals are provided. 29 refs., 38 figs., 8 tabs

  17. Analysis of end-face seals by FEM

    Directory of Open Access Journals (Sweden)

    Juraszek J.

    2002-09-01

    Full Text Available The end face-seals joint simultaneously the function of seal, bearing and heat exchanger. In order to improve the design of end-face seals the analysis of this type of joint by means of finite element method, was developed. The temperature distribution is indispensable to the analysis of displacement and stress in this type of face seal. In this work the values of temperature and stress in end-face seals were calculated. The numerical results were confirmed by measurements in the laboratory.

  18. Zinc

    Science.gov (United States)

    ... Some early research suggests that zinc supplementation increases sperm count, testosterone levels, and pregnancy rates in infertile men with low testosterone levels. Other research suggests that taking zinc can improve sperm shape in men with moderate enlargement of a ...

  19. Relationship between maternal serum zinc, cord blood zinc and ...

    African Journals Online (AJOL)

    Background: Adequate in utero supply of zinc is essential for optimal fetal growth because of the role of zinc in cellular division, growth and differentiation. Low maternal serum zinc has been reported to be associated with low birth weight and the later is associated with increased morbidity and mortality in newborns.

  20. Gastrostomy Tube (G-Tube)

    Science.gov (United States)

    ... any of these problems: a dislodged tube a blocked or clogged tube any signs of infection (including redness, swelling, or warmth at the tube site; discharge that's yellow, green, or foul-smelling; fever) excessive bleeding or drainage from the tube site severe abdominal pain lasting ...

  1. Tracheal tube and laryngeal mask cuff pressure during anaesthesia - mandatory monitoring is in need

    DEFF Research Database (Denmark)

    Rokamp, K.Z.; Secher, N.H.; Møller, Ann

    2010-01-01

    ABSTRACT: BACKGROUND: To prevent endothelium and nerve lesions, tracheal tube and laryngeal mask cuff pressure is to be maintained at a low level and yet be high enough to secure air sealing. METHOD: In a prospective quality-control study, 201 patients undergoing surgery during anaesthesia (without...... the use of nitrous oxide) were included for determination of the cuff pressure of the tracheal tubes and laryngeal masks. RESULTS: In the 119 patients provided with a tracheal tube, the median cuff pressure was 30 (range 8 - 100) cm H2O and the pressure exceeded 30 cm H2O (upper recommended level) for 54...... patients. In the 82 patients provided with a laryngeal mask, the cuff pressure was 95 (10 - 121) cm H2O and above 60 cm H2O (upper recommended level) for 56 patients and in 34 of these patients, the pressure exceeded the upper cuff gauge limit (120 cm H2O). There was no association between cuff pressure...

  2. Quick-sealing design for radiological containment

    International Nuclear Information System (INIS)

    Rampdla, D.S.; Speer, E.

    1991-01-01

    This patent describes a quick-sealing assembly and method for forming an adhesive seal on opposite sides of a mechanical seal for a flexible containment bag of the type used for working with radioactively contaminated objects. The assembly includes an elongated mechanical fastener having opposing engaging members affixed at a predetermined distance from each of the elongated edges, with an adhesive layer formed between the mechanical fastener and the elongated edge such that upon engagement of the mechanical fastener and adhesive layers to opposing containment fabric, a neat triple hermetic seal is formed

  3. Quick-sealing design for radiological containment

    International Nuclear Information System (INIS)

    Rampolia, D.S.; Speer, E.

    1990-01-01

    This patent describes a quick-sealing assembly and method for forming an adhesive seal on opposite sides of a mechanical seal for a flexible containment bag of the type used for working with radioactively contaminated objects. The assembly includes an elongated mechanical fastener having opposing engaging members affixed at a predetermined distance from each of the elongated edges, with an adhesive layer formed between the mechanical fastener and the elongated edge such that upon engagement of the mechanical fastener and adhesive layers to opposing containment fabric, a neat triple hermetic seal is formed

  4. Quick-sealing design for radiological containment

    Science.gov (United States)

    Rampolia, Donald S.; Speer, Elmer

    1990-01-01

    A quick-sealing assembly and method for forming an adhesive seal on opposite sides of a mechanical seal for a flexible containment bag of the type used for working with radioactively contaminated objects. The assembly includes an elongated mechanical fastener having opposing engaging members affixed at a predetermined distance from each of the elongated edges, with an adhesive layer formed between the mechanical fastener and the elongated edge such that upon engagement of the mechanical fastener and adhesive layers to opposing containment fabric, a neat triple hermetic seal is formed.

  5. Auto-identification fiberoptical seal verifier

    International Nuclear Information System (INIS)

    Yamamoto, Yoichi; Mukaiyama, Takehiro

    1998-08-01

    An auto COBRA seal verifier was developed by Japan Atomic Energy Research Institute (JAERI) to provide more efficient and simpler inspection measures for IAEA safeguards. The verifier is designed to provide means of a simple, quantitative and objective judgment on in-situ verification for the COBRA seal. The equipment is a portable unit with hand-held weight and size. It can be operated by battery or AC power. The verifier reads a COBRA seal signature by using a built-in CCD camera and carries out the signature comparison procedure automatically on digital basis. The result of signature comparison is given as a YES/NO answer. The production model of the verifier was completed in July 1996. The development was carried out in collaboration with Mitsubishi Heavy Industries, Ltd. This report describes the design and functions of the COBRA seal verifier and the results of environmental and functional tests. The development of the COBRA seal verifier was carried out in the framework of Japan Support Programme for Agency Safeguards (JASPAS) as a project, JD-4 since 1981. (author)

  6. Enzymatic determination of cadmium, zinc, and lead in plant materials

    International Nuclear Information System (INIS)

    Muginova, S.V.; Veselova, I.A.; Parova, L.M.; Shekhovtseva, T.N.

    2008-01-01

    Prospects are outlined for using the following enzymes (native and immobilized on polyurethane foam) in the rapid and highly sensitive determination of cadmium, zinc, and lead ions in plant materials (wild grass, fresh pea, and grape): horseradish peroxidase and alkaline phosphatases isolated from chicken intestine and Greenland seal small intestine. The analytical ranges of the above metals are 1x10 -3 -25; 7x10 -3 -250, and 3x10 -2 -67 mg/kg dry matter, respectively. The enzymatic determination procedures developed are based on the inhibiting effect of metal ions on the catalytic activity of peroxidase in the oxidation of o-dianisidine with hydrogen peroxide and alkaline phosphatases in the hydrolysis of p-nitrophenyl phosphate. The rates of enzymatic reactions were monitored spectrophotometrically or visually. In the analysis of plant extracts, their high acidity was diminished by choosing optimum dilution factors and pH values for test samples and the nature and concentration of a buffer solution. The interference of iron(III) was removed by introducing a 0.1 M tartaric acid solution into the indicator reaction. The accuracy of the results of the enzymatic determination of cadmium, zinc, and lead in plant materials was supported by atomic absorption spectrometry and anodic stripping voltammetry [ru

  7. The use of dual material seals for packaging

    International Nuclear Information System (INIS)

    Temus, C.J.; Nichols, J.C.

    2004-01-01

    The use of dual material seals, metal and elastomeric for a transportation package, provides a viable option for packages requiring high temperature seal capability. Allowing the seal area to go to higher temperatures then allowed for all elastomeric seal reduce the necessity of providing thermal protection during a postulated accident condition fire. It also increases the options for impact limiting features that do not also mitigate the affects of accident thermal events. Typically, high temperature seals require the use of metal O-rings. Only one seal (typically identified as the containment seal) needs to survive the hypothetical accident conditions, including the high temperatures that may occur during the prescribed hypothetical thermal event. However, to expedite the assembly leakage rate testing of radioactive material packages, a dual O-ring seal arrangement is often used to allow creation of a relatively small volume test cavity between the seals. For any package that is being used on a frequent basis, the total cost of seals can be significantly reduced by using an elastomeric seal as the secondary seal. The elastomeric seal is not the containment boundary seal and does not need to survive the high temperature condition. To get the dual material O-ring seals to seat properly, a different approach has to be taken than with closure of a radioactive material package that does not use metallic O-ring(s). A metal O-ring requires an application of a seating force while the elastomeric package requires a certain percentage of deformation. This is further complicated when the seating force is developed using a multi-bolt closure. Because of the nature of multi-bolt closures, elastic interaction prevents the equal application of force. This paper develops the methods involved in properly closing and establishing containment when using dual material seals with a multi-bolt closure. These methods were demonstrated in two production casks requiring testing leak

  8. BWR zinc addition Sourcebook

    International Nuclear Information System (INIS)

    Garcia, Susan E.; Giannelli, Joseph F.; Jarvis, Alfred J.

    2014-01-01

    Boiling Water Reactors (BWRs) have been injecting zinc into the primary coolant via the reactor feedwater system for over 25 years for the purpose of controlling primary system radiation fields. The BWR zinc injection process has evolved since the initial application at the Hope Creek Nuclear Station in 1986. Key transitions were from the original natural zinc oxide (NZO) to depleted zinc oxide (DZO), and from active zinc injection of a powdered zinc oxide slurry (pumped systems) to passive injection systems (zinc pellet beds). Zinc addition has continued through various chemistry regimes changes, from normal water chemistry (NWC) to hydrogen water chemistry (HWC) and HWC with noble metals (NobleChem™) for mitigation of intergranular stress corrosion cracking (IGSCC) of reactor internals and primary system piping. While past reports published by the Electric Power Research Institute (EPRI) document specific industry experience related to these topics, the Zinc Sourcebook was prepared to consolidate all of the experience gained over the past 25 years. The Zinc Sourcebook will benefit experienced BWR Chemistry, Operations, Radiation Protection and Engineering personnel as well as new people entering the nuclear power industry. While all North American BWRs implement feedwater zinc injection, a number of other BWRs do not inject zinc. This Sourcebook will also be a valuable resource to plants considering the benefits of zinc addition process implementation, and to gain insights on industry experience related to zinc process control and best practices. This paper presents some of the highlights from the Sourcebook. (author)

  9. Sealing of boreholes using natural, compatible materials: Granular salt

    International Nuclear Information System (INIS)

    Finley, R.E.; Zeuch, D.H.; Stormont, J.C.; Daemen, J.J.K.

    1994-01-01

    Granular salt can be used to construct high performance permanent seals in boreholes which penetrate rock salt formations. These seals are described as seal systems comprised of the host rock, the seal material, and the seal rock interface. The performance of these seal systems is defined by the complex interactions between these seal system components through time. The interactions are largely driven by the creep of the host formation applying boundary stress on the seal forcing host rock permeability with time. The immediate permeability of these seals is dependent on the emplaced density. Laboratory test results suggest that careful emplacement techniques could results in immediate seal system permeability on the order of 10 -16 m 2 to 10 -18 m 2 (10 -4 darcy to 10 -6 ). The visco-plastic behavior of the host rock coupled with the granular salts ability to ''heal'' or consolidate make granular salt an ideal sealing material for boreholes whose permanent sealing is required

  10. HFCVD Diamond-Coated Mechanical Seals

    Directory of Open Access Journals (Sweden)

    Raul Simões

    2018-05-01

    Full Text Available A mechanical seal promotes the connection between systems or mechanisms, preventing the escape of fluids to the exterior. Nonetheless, due to extreme working conditions, premature failure can occur. Diamond, due to its excellent properties, is heralded as an excellent choice to cover the surface of these devices and extend their lifetime. Therefore, the main objective of this work was to deposit diamond films over mechanical seals and test the coated seals on a water pump, under real working conditions. The coatings were created by hot filament chemical vapor deposition (HFCVD and two consecutive layers of micro- and nanocrystalline diamond were deposited. One of the main difficulties is the attainment of a good adhesion between the diamond films and the mechanical seal material (WC-Co. Nucleation, deposition conditions, and pre-treatments were studied to enhance the coating. Superficial wear or delamination of the film was investigated using SEM and Raman characterization techniques, in order to draw conclusions about the feasibility of these coatings in the WC-Co mechanical seals with the purpose of increasing their performance and life time. The results obtained gave a good indication about the feasibility of this process and the deposition conditions used, with the mechanical seals showing no wear and no film delamination after a real work environment test.

  11. Laboratory studies of fluid flow through borehole seals

    International Nuclear Information System (INIS)

    South, D.L.

    1983-01-01

    Boreholes in the vicinity of a nuclear waste repository must be reliably sealed to prevent rapid migration of radionuclide contaminated water from the vicinity of the repository to the accessible environment. Few data currently exist regarding the effectiveness of borehole sealing. The objective of this research was to assess the performance of borehole seals under laboratory conditions, particularly with regard to varying stress fields. The approach used to evaluate borehole seals was to compare flow through a sealed borehole with flow through intact rock. Granite, basalt, and tuff were tested, using either cement or bentonite as the seal material. The main conclusions reached as a result of the experiments is that currently existing materials are capable of forming high quality seals when placed under laboratory conditions. Variation of triaxial stress state about a borehole does not significantly affect seal performance if the rock is stiffer than the seal material. Temperature/moisture variations (drying) degraded the quality of cement seals significantly. Performance partially recovered upon resaturation. Significant remaining questions include field emplacement techniques; field vertification of plug quality; plug performance over long time periods, particularly with respect to temperature/moisture variations and chemical stability; and radionuclide sorption capabilities. Scale effects are also important, as shafts and drifts must be sealed as well as larger diameter boreholes

  12. Miniature magnetic fluid seal working in liquid environments

    Science.gov (United States)

    Mitamura, Yoshinori; Durst, Christopher A.

    2017-06-01

    This study was carried out to develop a miniature magnetic fluid (MF) seal working in a liquid environment. The miniature MF seal is intended for use in a catheter blood pump. The requirements for the MF seal included a size of less than Ø4×4.5 mm, shaft diameter of 1 mm, sealing pressure of 200 mmHg, shaft speed of up to 40000 rpm, and life of one month. The miniature MF seal was composed of an NdFeB magnet (Ø4×Ø2×1) sandwiched between two pole pieces (Ø4×Ø1.1×0.5). A shield (Ø4×Ø1.2×1.5) was placed on the pole piece facing the liquid to minimize the influence of pump flow on the MF. The seal was installed on a Ø1 shaft. A seal was formed by injecting MF (Ms: 47.8 kA/m and η: 0.5 Pa·sec) into the gap between the pole pieces and the shaft. Total volume of the MF seal was 44 μL. A sealing pressure of 370 mmHg was obtained at motor speeds of 0-40,000 rpm. The seal remained perfect for 10 days in saline under the condition of a pump flow of 1.5 L/min (The test was terminated in accordance with plans). The seal remained intact after ethylene oxide sterilization during which the seal was exposed to high pressures. In conclusion, the newly developed MF seal will be useful for a catheter pump.

  13. Zinc at glutamatergic synapses.

    Science.gov (United States)

    Paoletti, P; Vergnano, A M; Barbour, B; Casado, M

    2009-01-12

    It has long been known that the mammalian forebrain contains a subset of glutamatergic neurons that sequester zinc in their synaptic vesicles. This zinc may be released into the synaptic cleft upon neuronal activity. Extracellular zinc has the potential to interact with and modulate many different synaptic targets, including glutamate receptors and transporters. Among these targets, NMDA receptors appear particularly interesting because certain NMDA receptor subtypes (those containing the NR2A subunit) contain allosteric sites exquisitely sensitive to extracellular zinc. The existence of these high-affinity zinc binding sites raises the possibility that zinc may act both in a phasic and tonic mode. Changes in zinc concentration and subcellular zinc distribution have also been described in several pathological conditions linked to glutamatergic transmission dysfunctions. However, despite intense investigation, the functional significance of vesicular zinc remains largely a mystery. In this review, we present the anatomy and the physiology of the glutamatergic zinc-containing synapse. Particular emphasis is put on the molecular and cellular mechanisms underlying the putative roles of zinc as a messenger involved in excitatory synaptic transmission and plasticity. We also highlight the many controversial issues and unanswered questions. Finally, we present and compare two widely used zinc chelators, CaEDTA and tricine, and show why tricine should be preferred to CaEDTA when studying fast transient zinc elevations as may occur during synaptic activity.

  14. Application of EIS to In Situ Characterization of Hydrothermal Sealing of Anodized Aluminum Alloys: Comparison between Hexavalent Chromium-Based Sealing, Hot Water Sealing and Cerium-Based Sealing

    OpenAIRE

    Carangelo, Anna; Curioni, Michele; Acquesta, Annalisa; Monetta, Tullio; Bellucci, Francesco

    2016-01-01

    Chromic acid anodizing has been used for almost a century to enhance corrosion protection of aerospace alloys. For some applications,hydrothermal sealing in hexavalent chromium-containing solution is required to enhance further the corrosion resistance but, due toenvironmental concerns, the use of hexavalent chromium must be discontinued. Good progress has been made to replace chromatesduring anodizing but comparatively less effort has focused on the sealing process. In this work, for the fir...

  15. Reactor coolant pump seal leakage monitoring

    International Nuclear Information System (INIS)

    Stevens, D.M.; Spencer, J.W.; Morris, D.J.; James, W.; Shugars, H.G.

    1986-01-01

    Problems with reactor coolant pump seals have historically accounted for a large percentage of unscheduled outages. Studies performed for the Electric Power Research Institute (EPRI) have shown that the replacement of coolant pump seals has been one of the leading causes of nuclear plant unavailability over the last ten years. Failures of coolant pump seals can lead to primary coolant leakage rates of 200-500 gallons per minute into the reactor building. Airborne activity and high surface contamination levels following these failures require a major cleanup effort and increases the time and personnel exposure required to refurbish the pump seals. One of the problems in assessing seal integrity is the inability to accurately measure seal leakage. Because seal leakage flow is normally very small, it cannot be sensed directly with normal flow instrumentation, but must be inferred from several other temperature and flow measurements. In operating plants the leakage rate has been quantified with a tipping-bucket gauge, a device which indicates when one quart of water has been accumulated. The tipping-bucket gauge has been used for most rainfall-intensity monitoring. The need for a more accurate and less expensive gauge has been addressed. They have developed a drop-counter precipitation sensor has been developed and optimized. The applicability of the drop-counter device to the problem of measuring seal leakage is being investigated. If a review of system specification and known drop-counter performance indicates that this method is feasible for measuring seal leak rates, a drop-counter gauge will be fabricated and tested in the laboratory. If laboratory tests are successful the gauge will be demonstrated in a pump test loop at Ontario Hydro and evaluated under simulated plant conditions. 3 references, 2 figures

  16. Numerical Investigation on Windback Seals Used in Aero Engines

    Directory of Open Access Journals (Sweden)

    Michael Flouros

    2018-01-01

    Full Text Available Seals are considered one of the most important flow elements in turbomachinery applications. The most traditional and widely known seal is the labyrinth seal but in recent years other types like the brush or carbon seals were introduced since they considerably reduce the sealing air consumption. When seals are used for sealing of aero engine bearing chambers they are subjected to high “bombardment” through oil particles which are present in the bearing chamber. These particles mainly result from the bearings as a consequence of the high rotational speeds. Particularly when carbon or brush seals are used, problems with carbon formation (coking may arise when oil gets trapped in the very tight gap of these seals. In order to prevent oil migration into the turbomachinery, particularly when the pressure difference over a seal is small or even negligible, significant improvement can be achieved through the introduction of so called windback seals. This seal has a row of static helical teeth (thread and below this thread a scalloped or smooth shaft section is rotating. Depending on the application, a windback seal can be used alone or as a combination with another seal (carbon, brush or labyrinth seal. A CFD analysis carried out with ANSYS CFX version 11 is presented in this paper with the aim to investigate this seal type. The simulations were performed by assuming a two-phase flow of air and oil in the bearing compartment. Design parameters like seal clearance, thread size, scallop width, were investigated at different operating conditions.

  17. Sealing Occlusal Dentin Caries in Permanent Molars

    DEFF Research Database (Denmark)

    Qvist, Vibeke; Borum, Mette Kit; Møller, Kirsten Dynes

    2017-01-01

    The purpose of this study was to investigate the possibility of postponing restorative intervention of manifest occlusal caries in young, permanent dentition by non-invasive sealing. This RCT-designed study included 521 occlusal lesions in 521 patients aged 6 to 17 y. Based on clinical and radiog......The purpose of this study was to investigate the possibility of postponing restorative intervention of manifest occlusal caries in young, permanent dentition by non-invasive sealing. This RCT-designed study included 521 occlusal lesions in 521 patients aged 6 to 17 y. Based on clinical...... longevity of sealings and restorations until retreatments, and 3) compare effectiveness of sealings and restorations to halt caries progression in sealed lesions and beneath restorations. Furthermore, we aimed to identify factors influencing longevity and the effectiveness of sealings and restorations.......001). The median survival time for sealings not replaced by restorations was 7.3 y (CI, 6.4 y to NA). Survival of sealings was increased in patients with low caries risk and/or excellent oral hygiene, second molars compared with first molars, and lesions not extending the middle one-third of the dentin. Survival...

  18. Tracing of Zinc Nanocrystals in the Anterior Pituitary of Zinc-Deficient Wistar Rats.

    Science.gov (United States)

    Kuldeep, Anjana; Nair, Neena; Bedwal, Ranveer Singh

    2017-06-01

    The aim of this study was to trace zinc nanocrystals in the anterior pituitary of zinc-deficient Wistar rats by using autometallographic technique. Male Wistar rats (30-40 days of age, pre-pubertal period) of 40-50 g body weight were divided into the following: the ZC (zinc control) group-fed with 100 ppm zinc in diet, the ZD (zinc-deficient) group-fed with zinc-deficient (1.00 ppm) diet and the PF (pair-fed) group-received 100 ppm zinc in diet. The experiments were set for 2 and 4 weeks. Pituitary was removed and processed for the autometallographic technique. The control and pair-fed groups retained their normal morphological features. However, male Wistar rats fed on zinc-deficient diet for 2 and 4 weeks displayed a wide range of symptoms such as significant (P zinc nanocrystals in the nuclei. The present findings suggest that the dietary zinc deficiency causes decreased intensity of zinc nanocrystals localization and their distribution in the pituitary thereby contributing to the dysfunction of the pituitary of the male Wistar rats. The severity of zinc deficiency symptoms progressed after the second week of the experiment. Decreased intensity of zinc nanocrystals attenuates the pituitary function which would exert its affect on other endocrine organs impairing their functions indicating that the metabolic regulation of pituitary is mediated to a certain extent by zinc and/or hypothalamus-hypophysial system which also reflects its essentiality during the period of growth.

  19. Metal and elastomer seal tests for accelerator applications

    International Nuclear Information System (INIS)

    Welch, K.M.; McIntyre, G.T.; Tuozzolo, J.E.; Skelton, R.; Pate, D.J.; Gill, S.M.

    1989-01-01

    The vacuum system of the Alternating Gradient Synchrotron (AGS) at Brookhaven National Laboratory has more than a thousand metal vacuum seals. Also, numerous elastomer seals are used throughout the AGS to seal large beam component chambers. An accelerator upgrade program is being implemented to reduce the AGS operating pressure by x100 and improve the reliability of the vacuum system. This paper describes work in progress on metal and elastomer vacuum seals to help meet those two objectives. Tests are reported on the sealing properties of a variety of metal seals used on different sealing surfaces. Results are also given on reversible sorption properties of certain elastomers. 16 refs., 6 figs., 4 tabs

  20. Apparatus and method for inspecting a sealed container

    Science.gov (United States)

    Harmon, J Frank [Pocatello, ID; Jones, James L [Idaho Falls, ID; Hunt, Alan W [Pocatello, ID; Spaulding, Randy J [Pocatello, ID; Smith, Michael [Phoenix, AZ

    2009-03-24

    An apparatus for inspecting a sealed container is disclosed and which includes a pulsed electron accelerator which is positioned in spaced relation relative to a first side of the sealed container, and which produces a pulsed beam of photons which passes through the sealed container and any contents enclosed within the sealed container; a detector positioned in spaced relation relative to a second, opposite side of the sealed container, and which receives the pulsed beam of photons which passes through the contents of the sealed container, and which produces an output signal; and a computer for developing a visible image from the output signal of the detector which depicts the contents of the sealed container.

  1. Selection of vacuum seals for EBT-P

    International Nuclear Information System (INIS)

    Dillow, C.F.; Adlon, G.L.; Stubblefield, V.E.

    1981-01-01

    Elmo Bumpy Torus Proof of Principle (EBT-P) is a magnetic fusion RandD facility being constructed by McDonnell Douglas Astronautics Company - St. Louis Division of Oak Ridge National Laboratory (ORNL). EBT-P is a truly unique fusion device requiring careful consideration in selecting both the primary vacuum seals on the toroidal vessel and the secondary vacuum seals in components such as vacuum pumps and and valves. The vacuum seal environment is described and the considerations in vacuum seal selection fully discussed. Methods for protecting vacuum seals in pumps and valves from the microwave environments are also presented

  2. Seal analysis technology for reactor pressure vessel

    International Nuclear Information System (INIS)

    Zheng Liangang; Zhang Liping; Yang Yu; Zang Fenggang

    2009-01-01

    There is the coolant with radiation, high temperature and high pressure in the reactor pressure vessel (RPV). It is closely correlated to RPV sealing capability whether the whole nuclear system work well or not. The aim of this paper is to study the seal analysis method and technology, such as the pre-tensioning of the bolt, elastoplastic contact and coupled technology of thermal and structure. The 3 D elastoplastic seal analysis method really and generally consider the loads and model the contact problem with friction between the contact plates. This method is easier than the specialized seal program and used widely. And it is more really than the 2 D seal analysis method. This 3 D elastoplastic seal analysis method has been successfully used in the design and analysis of RPV. (authors)

  3. Sealed radioactive sources toolkit

    International Nuclear Information System (INIS)

    Mac Kenzie, C.

    2005-09-01

    The IAEA has developed a Sealed Radioactive Sources Toolkit to provide information to key groups about the safety and security of sealed radioactive sources. The key groups addressed are officials in government agencies, medical users, industrial users and the scrap metal industry. The general public may also benefit from an understanding of the fundamentals of radiation safety

  4. Method and system to facilitate sealing in gas turbines

    Science.gov (United States)

    Morgan, Victor John; Foster, Gregory Thomas; Sarawate, Neelesh Nandkumar

    2017-09-12

    A method and system for sealing between components within a gas turbine is provided. A first recess defined in a first component receives a seal member. A second recess defined in a second component adjacent the first component also receives the seal member. The first and second recesses are located proximate a hot gas path defined through the gas turbine, and define circumferential paths about the turbine axis. The seal member includes a sealing face that extends in a direction substantially parallel to the turbine axis. The seal member also includes a plurality of seal layers, wherein at least one of the seal layers includes at least one stress relief region for facilitating flexing of the first seal member.

  5. Silicone foam for penetration seal

    International Nuclear Information System (INIS)

    Hoshino, Yoshikazu

    1986-01-01

    In nuclear power plants or general buildings, it is very important to form a fire-resistant seal around cables, cable trays and conduits passing through a wall or a floor. Rockwool, asbestos, glasswool and flame-retarded urethane foam have so far been used for these purposes. However, they were not satisfactory in sealing property, workability and safety. The silicone foam newly developed, ''TOSSEAL'' 300, has cleared these defects. It has now come to be used for fire resistant seal in nuclear power plants. (author)

  6. Infiltrating/sealing proximal caries lesions

    DEFF Research Database (Denmark)

    Martignon, S; Ekstrand, K R; Gomez, J

    2012-01-01

    This randomized split-mouth controlled clinical trial aimed at assessing the therapeutic effects of infiltration vs. sealing for controlling caries progression on proximal surfaces. Out of 90 adult students/patients assessed at university clinics and agreeing to participate, 39, each with 3...... differences in lesion progression between infiltration and placebo (P = 0.0012) and between sealing and placebo (P = 0.0269). The study showed that infiltration and sealing are significantly better than placebo treatment for controlling caries progression on proximal lesions. No significant difference...

  7. Cost saving synergistic shaft seal

    Science.gov (United States)

    Ludwig, L. P.; Strom, T. N.

    1976-01-01

    Segmented carbon rings, used to replace elastomeric seal lip, provide resistance to high temperatures generated in lubricating film. Machining and close manufacturing tolerances of conventional segmented seal are avoided by mounting segmented rings in elastomeric flex section.

  8. Development of a ceramic tamper indicating seal: SRNL contributions

    International Nuclear Information System (INIS)

    Krementz, Dan; Brinkman, Kyle S.; Martinez-Rodriguez, Michael J.; Mendez-Torres, Adrian E.; Weeks, George E.

    2013-01-01

    Savannah River National Laboratory (SRNL) and Sandia National Laboratories (SNL) are collaborating on development of a Ceramic Seal, also sometimes designated the Intrinsically Tamper Indicating Ceramic Seal (ITICS), which is a tamper indicating seal for international safeguards applications. The Ceramic Seal is designed to be a replacement for metal loop seals that are currently used by the IAEA and other safeguards organizations. The Ceramic Seal has numerous features that enhance the security of the seal, including a frangible ceramic body, protective and tamper indicating coatings, an intrinsic unique identifier using Laser Surface Authentication, electronics incorporated into the seal that provide cryptographic seal authentication, and user-friendly seal wire capture. A second generation prototype of the seal is currently under development whose seal body is of Low Temperature Co-fired Ceramic (LTCC) construction. SRNL has developed the mechanical design of the seal in an iterative process incorporating comments from the SNL vulnerability review team. SRNL is developing fluorescent tamper indicating coatings, with recent development focusing on optimizing the durability of the coatings and working with a vendor to develop a method to apply coatings on a 3-D surface. SRNL performed a study on the effects of radiation on the electronics of the seal and possible radiation shielding techniques to minimize the effects. SRNL is also investigating implementation of Laser Surface Authentication (LSA) as a means of unique identification of each seal and the effects of the surface coatings on the LSA signature.

  9. DEVELOPMENT OF A CERAMIC TAMPER INDICATING SEAL: SRNL CONTRIBUTIONS

    Energy Technology Data Exchange (ETDEWEB)

    Krementz, D.; Brinkman, K.; Martinez-Rodriguez, M.; Mendez-Torres, A.; Weeks, G.

    2013-06-03

    Savannah River National Laboratory (SRNL) and Sandia National Laboratories (SNL) are collaborating on development of a Ceramic Seal, also sometimes designated the Intrinsically Tamper Indicating Ceramic Seal (ITICS), which is a tamper indicating seal for international safeguards applications. The Ceramic Seal is designed to be a replacement for metal loop seals that are currently used by the IAEA and other safeguards organizations. The Ceramic Seal has numerous features that enhance the security of the seal, including a frangible ceramic body, protective and tamper indicating coatings, an intrinsic unique identifier using Laser Surface Authentication, electronics incorporated into the seal that provide cryptographic seal authentication, and user-friendly seal wire capture. A second generation prototype of the seal is currently under development whose seal body is of Low Temperature Co-fired Ceramic (LTCC) construction. SRNL has developed the mechanical design of the seal in an iterative process incorporating comments from the SNL vulnerability review team. SRNL is developing fluorescent tamper indicating coatings, with recent development focusing on optimizing the durability of the coatings and working with a vendor to develop a method to apply coatings on a 3-D surface. SRNL performed a study on the effects of radiation on the electronics of the seal and possible radiation shielding techniques to minimize the effects. SRNL is also investigating implementation of Laser Surface Authentication (LSA) as a means of unique identification of each seal and the effects of the surface coatings on the LSA signature.

  10. Improved sealing for in-core systems

    International Nuclear Information System (INIS)

    Dunford, S.

    1989-01-01

    The in-core instrumentation sealing nozzles designed by Framatome have three mechanical seals in series instead of the one traditional seal, and are pressurized by simply tightening up the nozzle covers. They have been installed from the start on all Framatome PWRs, as well as having been backfitted on Belgium and Yugoslavian units and chosen for the Chinese Qinshan plant. (author)

  11. Multi-Canister overpack sealing configuration

    International Nuclear Information System (INIS)

    SMITH, K.E.

    1998-01-01

    The Spent Nuclear Fuel (SNF) position regarding the Multi-Canister Overpack (MCO) sealing configuration is to initially rely on an American Society of Mechanical Engineers (ASME) Section III Subsection NB code compliant mechanical closure/sealing system to quickly and safely establish and maintain full confinement of radioactive materials prior to and during MCO fuel drying activities. Previous studies have shown the mechanical seal to be the preferred closure method, based on dose, cost, and schedule considerations. The cost and schedule impacts of redesigning the mechanical closure to a welded shield plug do not support changing the closure system. The SNF Project has determined that the combined mechanical/welded closure system meets or exceeds the regulatory requirements to provide redundant seals while accommodating key safety and schedule limitations that are unique to K Basins fuel removal effort

  12. Coupled processes in repository sealing

    International Nuclear Information System (INIS)

    Case, J.B.; Kelsall, P.C.

    1985-01-01

    The significance of coupled processes in repository sealing is evaluated. In most repository designs, shaft seals will be located in areas of relatively low temperature perturbation, in which case the coupling of temperature with stress and permeability may be less significant than the coupling between stress and permeability that occurs during excavation. Constitutive relationships between stress and permeability are reviewed for crystalline rock and rocksalt. These provide a basis for predicting the development of disturbed zones near excavations. Field case histories of the degree of disturbance are presented for two contrasting rock types - Stripa granite and Southeastern New Mexico rocksalt. The results of field investigations in both rock types confirm that hydraulic conductivity or permeability is stress dependent, and that shaft seal performance may be related to the degree that stresses are perturbed and restored near the seal

  13. Sealing glasses for titanium and titanium alloys

    Science.gov (United States)

    Brow, Richard K.; McCollister, Howard L.; Phifer, Carol C.; Day, Delbert E.

    1997-01-01

    Barium lanthanoborate sealing-glass compositions are provided comprising various combinations (in terms of mole-%) of boron oxide (B.sub.2 O.sub.3), barium oxide (BaO), lanthanum oxide (La.sub.2 O.sub.3), and at least one other oxide selected from the group consisting of aluminum oxide (Al.sub.2 O.sub.3), calcium oxide (CaO), lithium oxide (Li.sub.2 O), sodium oxide (Na.sub.2 O), silicon dioxide (SiO.sub.2), or titanium dioxide (TiO.sub.2). These sealing-glass compositions are useful for forming hermetic glass-to-metal seals with titanium and titanium alloys having an improved aqueous durability and favorable sealing characteristics. Examples of the sealing-glass compositions are provided having coefficients of thermal expansion about that of titanium or titanium alloys, and with sealing temperatures less than about 900.degree. C., and generally about 700.degree.-800.degree. C. The barium lanthanoborate sealing-glass compositions are useful for components and devices requiring prolonged exposure to moisture or water, and for implanted biomedical devices (e.g. batteries, pacemakers, defibrillators, pumps).

  14. Development of Advanced Carbon Face Seals for Aircraft Engines

    Science.gov (United States)

    Falaleev, S. V.; Bondarchuk, P. V.; Tisarev, A. Yu

    2018-01-01

    Modern aircraft gas turbine engines require the development of seals which can operate for a long time with low leakages. The basic type of seals applied for gas turbine engine rotor supports is face seal. To meet the modern requirements of reliability, leak-tightness and weight, low-leakage gas-static and hydrodynamic seals have to be developed. Dry gas seals use both gas-static and hydrodynamic principles. In dry gas seals microgrooves are often used, which ensure the reverse injection of leakages in the sealed cavity. Authors have developed a calculation technique including the concept of coupled hydrodynamic, thermal and structural calculations. This technique allows to calculate the seal performance taking into account the forces of inertia, rupture of the lubricant layer and the real form of the gap. Authors have compared the efficiency of seals with different forms of microgrooves. Results of calculations show that seal with rectangular form of microgrooves has a little gap leading to both the contact of seal surfaces and the wear. Reversible microgrooves have a higher oil mass flow rate, whereas HST micro-grooves have good performance, but they are difficult to produce. Spiral microgrooves have both an acceptable leakages and a high stiffness of liquid layer that is important in terms of ensuring of sealing performance at vibration conditions. Therefore, the spiral grooves were chosen for the developed seal. Based on calculation results, geometric dimensions were chosen to ensure the reliability of the seal operation by creating a guaranteed liquid film, which eliminates the wear of the sealing surfaces. Seals designed were tested both at the test rig and in the engine.

  15. PREPARATION OF ZINC ENRICHED YEAST (SACCHAROMYCES CEREVISIAE BY CULTIVATION WITH DIFFERENT ZINC SALTS

    Directory of Open Access Journals (Sweden)

    Ľuboš Harangozo

    2012-02-01

    Full Text Available The yeast Saccharomyces cerevisiae is the best known microorganism and therefore widely used in many branches of industry. This study aims to investigate the accumulation of three inorganic zinc salts. Our research presents the ability of this yeast to absorb zinc from liquid medium and such enriched biomass use as a potential source of microelements in animal and/or human nutrition. It was found that the addition of different zinc forms, i.e. zinc nitrate, zinc sulphate and zinc chloride in fixed concentrations of 0, 25, 50 and 100 mg.100 ml-1 did not affect the amount of dry yeast biomass yielded, i.e. 1.0 – 1.2 g of yeast cells from 100 ml of cultivation medium, while higher presence of zinc solutions caused significantly lower yield of yeast biomass. The highest amount of zinc in yeast cells was achieved when added in the form of zinc nitrate in concentration of 200 mg.100 ml-1 YPD medium. The increment of intracellular zinc was up to 18.5 mg.g-1 of yeast biomass.

  16. Reactor coolant pump seals: improving their performance

    International Nuclear Information System (INIS)

    Pothier, N.E.; Metcalfe, R.

    1986-06-01

    Large CANDU plants are benefitting from transient-resistant four-year reliable reactor coolant pump seal lifetimes, a direct result of AECL's 20-year comprehensive seal improvement program involving R and D staff, manufacturers, and plant designers and operators. An overview of this program is presented, which covers seal modification design, testing, post-service examination, specialized maintenance and quality control. The relevancy of this technology to Light Water Reactor Coolant Pump Seals is also discussed

  17. Development of simplified rotating plug seal structure

    International Nuclear Information System (INIS)

    Ueta, M.; Ichimiya, M.; Kanaoka, T.; Sekiya, H.; Ueda, S.; Ishibashi, S.

    1991-01-01

    We studied a compact and simplified rotating plug seal structure and conducted experiments for key elements of the concept such us the mechanical seal structure and sodium deposit prevention system. Good characteristics were confirmed for the mechanical seal structure, which utilizes an elastomer seal and thin lathe bearing. Applicability of the density barrier concept was also confirmed as the sodium deposit prevention system. This concept can be applied to actual plants. (author)

  18. Application study of magnetic fluid seal in hydraulic turbine

    International Nuclear Information System (INIS)

    Yu, Z Y; Zhang, W

    2012-01-01

    The waterpower resources of our country are abundant, and the hydroelectric power is developed, but at present the main shaft sealing device of hydraulic turbine is easy to wear and tear and the leakage is great. The magnetic fluid seal has the advantages of no contact, no wear, self-healing, long life and so on. In this paper, the magnetic fluid seal would be used in the main shaft of hydraulic turbine, the sealing structure was built the model, meshed the geometry, applied loads and solved by using MULTIPHYSICS in ANSYS software, the influence of the various sealing structural parameters such as tooth width, height, slot width, sealing gap on the sealing property were analyzed, the magnetic fluid sealing device suitable for large-diameter shaft and sealing water was designed, the sealing problem of the hydraulic turbine main shaft was solved effectively which will bring huge economic benefits.

  19. The study and microstructure analysis of zinc and zinc oxide

    Czech Academy of Sciences Publication Activity Database

    Luptáková, Natália; Pešlová, F.; Kliber, J.

    2015-01-01

    Roč. 54, č. 1 (2015), s. 43-46 ISSN 0543-5846 Grant - others:KEGA(SK) KEGA 007 TnUAD-4/2013 Institutional support: RVO:68081723 Keywords : zinc * production of zinc oxide * microstructure * chemical composition * zinc slag Subject RIV: JG - Metal lurgy Impact factor: 0.959, year: 2014

  20. Zinc Biochemistry: From a Single Zinc Enzyme to a Key Element of Life12

    Science.gov (United States)

    Maret, Wolfgang

    2013-01-01

    The nutritional essentiality of zinc for the growth of living organisms had been recognized long before zinc biochemistry began with the discovery of zinc in carbonic anhydrase in 1939. Painstaking analytical work then demonstrated the presence of zinc as a catalytic and structural cofactor in a few hundred enzymes. In the 1980s, the field again gained momentum with the new principle of “zinc finger” proteins, in which zinc has structural functions in domains that interact with other biomolecules. Advances in structural biology and a rapid increase in the availability of gene/protein databases now made it possible to predict zinc-binding sites from metal-binding motifs detected in sequences. This procedure resulted in the definition of zinc proteomes and the remarkable estimate that the human genome encodes ∼3000 zinc proteins. More recent developments focus on the regulatory functions of zinc(II) ions in intra- and intercellular information transfer and have tantalizing implications for yet additional functions of zinc in signal transduction and cellular control. At least three dozen proteins homeostatically control the vesicular storage and subcellular distribution of zinc and the concentrations of zinc(II) ions. Novel principles emerge from quantitative investigations on how strongly zinc interacts with proteins and how it is buffered to control the remarkably low cellular and subcellular concentrations of free zinc(II) ions. It is fair to conclude that the impact of zinc for health and disease will be at least as far-reaching as that of iron. PMID:23319127

  1. Dynamic Measurements of Plastic Deformation in a Water-Filled Aluminum Tube in Response to Detonation of a Small Explosives Charge

    Directory of Open Access Journals (Sweden)

    Harold Sandusky

    1999-01-01

    Full Text Available Experiments have been conducted to benchmark computer code calculations for the dynamic interaction of explosions in water with structures. Aluminum cylinders with a length slightly more than twice their diameter were oriented vertically, sealed on the bottom by a thin plastic sheet, and filled with distilled water. An explosive charge suspended in the center of the tube plastically deformed but did not rupture the wall. Tube wall velocity, displacement, and strain were directly measured. The agreement among the three sets of dynamic data and the agreement of the terminal displacement measurements with the residual deformation were excellent.

  2. Sealing apparatus for airfoils of gas turbine engines

    Science.gov (United States)

    Jones, R.B.

    1998-05-19

    An improved airfoil tip sealing apparatus is disclosed wherein brush seals are attached to airfoil tips with the distal ends of the brush seal fibers sealingly contacting opposing wall surfaces. Embodiments for variable vanes, stators and both cooled and uncooled turbine blade applications are disclosed. 17 figs.

  3. Reactor coolant pump shaft seal stability during station blackout

    International Nuclear Information System (INIS)

    Rhodes, D.B.; Hill, R.C.; Wensel, R.G.

    1987-05-01

    Results are presented from an investigation into the behavior of Reactor Coolant Pump shaft seals during a potential station blackout (loss of all ac power) at a nuclear power plant. The investigation assumes loss of cooling to the seals and focuses on the effect of high temperature on polymer seals located in the shaft seal assemblies, and the identification of parameters having the most influence on overall hydraulic seal performance. Predicted seal failure thresholds are presented for a range of station blackout conditions and shaft seal geometries

  4. Reactor coolant pump shaft seal stability during station blackout

    Energy Technology Data Exchange (ETDEWEB)

    Rhodes, D B; Hill, R C; Wensel, R G

    1987-05-01

    Results are presented from an investigation into the behavior of Reactor Coolant Pump shaft seals during a potential station blackout (loss of all ac power) at a nuclear power plant. The investigation assumes loss of cooling to the seals and focuses on the effect of high temperature on polymer seals located in the shaft seal assemblies, and the identification of parameters having the most influence on overall hydraulic seal performance. Predicted seal failure thresholds are presented for a range of station blackout conditions and shaft seal geometries.

  5. An experimental study of the retention of zinc, zinc-cadmium mixture and zinc-65 in the presence of cadmium in Anguilla anguilla (L.)

    International Nuclear Information System (INIS)

    Pally, Monique; Foulquier, Luc

    1976-07-01

    Zinc uptake was studied in eels in fresh water, using stable zinc, a zinc-cadmium mixture, and zinc 65 in the presence of small amounts of cadmium. The zinc content in the eel began to increase after 45 days only, and reached approximately 85 ppm after 76 days in water initially containing 5ppm of zinc. At the conclusion of the experiment (76 days), the body organs could be classified in decreasing order in zinc content (in ppm): kidneys (152), skeleton (133), skin (129), muscles (89), head (80), gills (78), digestive tract (77), liver (63) spleen-heart-air bladder (32), and mucus (15). A comparison of experimental results obtained with the zinc-cadmium mixture and cadmium alone showed that zinc decreased the cadmium content of all organs except the gills. The presence of cadmium in water did not inhibit zinc uptake. As cadmium content in water increased, then zinc content in the digestive tract and the kidneys decreased and in all cases remained lower than when zinc alone was present. In the presence of cadmium the percentage of zinc in the kidneys was always lower than the value obtained for zinc alone, and that of the digestive tract did not increase. Contamination of eels treated with 18 and 50ppb of cadmium for 29 days, then contaminated by zinc-65 (5μCi/l) while maintaining the same low cadmium content, showed no significant difference in zinc 65 uptake in the two groups. The same applied to the body organs, and particularly the digestive tract and kidneys, where the highest activity levels were observed. By weight, muscles represented approximately 30% of the total contamination after 45 days [fr

  6. Effect of zinc sources on yield and utilization of zinc in rice-wheat sequence

    International Nuclear Information System (INIS)

    Deb, D.L.

    1990-01-01

    A field experiment was conducted on an inceptisol of Delhi to evaluate three sources of zinc, namely, zinc sulphate, zincated urea and zinc oxide on yield and utilization of zinc in rice-wheat sequence. Results indicated that, amongst the three zinc sources, zinc sulphate and zincated urea gave the best performance in increasing the grain yield of rice whereas zinc oxide depressed the grain yield of wheat significantly when compared to other treatments. The highest Zn derived from fertilizer and its utilization was obtained with zinc sulphate for both rice and wheat crops. (author). 9 refs., 4 tabs

  7. Zinc blotting assay for detection of zinc binding prolamin in barley (Hordeum vulgare) grain

    DEFF Research Database (Denmark)

    Uddin, Mohammad Nasir; Nielsen, Ane Langkilde-Lauesen; Vincze, Eva

    2014-01-01

    In plants, zinc is commonly found bound to proteins. In barley (Hordeum vulgare), major storage proteins are alcohol-soluble prolamins known as hordeins, and some of them have the potential to bind or store zinc. 65Zn overlay and blotting techniques have been widely used for detecting zinc......-binding protein. However, to our knowledge so far this zinc blotting assay has never been applied to detect a prolamin fraction in barley grains. A radioactive zinc (65ZnCl2) blotting technique was optimized to detect zinc-binding prolamins, followed by development of an easy-to-follow nonradioactive colorimetric...... zinc blotting method with a zinc-sensing dye, dithizone. Hordeins were extracted from mature barley grain, separated by SDS-PAGE, blotted on a membrane, renatured, overlaid, and probed with zinc; subsequently, zinc-binding specificity of certain proteins was detected either by autoradiography or color...

  8. Trace element analysis in the serum and hair of Antarctic leopard seal, Hydrurga leptonyx, and Weddell seal, Leptonychotes weddellii

    Energy Technology Data Exchange (ETDEWEB)

    Gray, Rachael [Faculty of Veterinary Science, University of Sydney, NSW 2006 Australia (Australia); Australian Marine Mammal Research Centre PO Box 20 Mosman, NSW 2088 (Australia)], E-mail: rgray@vetsci.usyd.edu.au; Canfield, Paul [Faculty of Veterinary Science, University of Sydney, NSW 2006 (Australia); Rogers, Tracey [Australian Marine Mammal Research Centre PO Box 20 Mosman, NSW 2088 (Australia); Evolution and Ecology Research Centre and School of Biological Earth and Environmental Sciences, University of New South Wales, NSW 2052 (Australia)

    2008-07-25

    Leopard seal, Hydrurga leptonyx, and Weddell seal, Leptonychotes weddellii, occupy an upper trophic level within the Antarctic ecosystem and are useful indicator species in the Southern Ocean of trace element concentrations. Reference values for the concentration of 19 trace elements were determined in the serum and hair of leopard and Weddell seals sampled in Eastern Antarctica. These reference values can be used as 'baseline' levels for monitoring trace element concentrations in these species. Greater trace element concentrations were determined in hair compared to serum, indicating different time scales of trace element accumulation in these samples. For the majority of trace elements, except for Se in the leopard seal samples and Cr in the Weddell seal samples, significant regression relationships for trace element concentrations in hair and serum were not elucidated. Significant differences were determined in the concentrations of seven out of 15 elements with hair type, moult and new, in the leopard seal; concentrations in moult hair were determined to be greater than in new hair for all elements except Zn. Hair analysis was determined to be useful for monitoring exposure to trace elements and when collected off the ice from moulting seals, hair can be employed as a non-invasive sample for trace element analysis in leopard and Weddell seals.

  9. Solid oxide fuel cell having a glass composite seal

    Science.gov (United States)

    De Rose, Anthony J.; Mukerjee, Subhasish; Haltiner, Jr., Karl Jacob

    2013-04-16

    A solid oxide fuel cell stack having a plurality of cassettes and a glass composite seal disposed between the sealing surfaces of adjacent cassettes, thereby joining the cassettes and providing a hermetic seal therebetween. The glass composite seal includes an alkaline earth aluminosilicate (AEAS) glass disposed about a viscous glass such that the AEAS glass retains the viscous glass in a predetermined position between the first and second sealing surfaces. The AEAS glass provides geometric stability to the glass composite seal to maintain the proper distance between the adjacent cassettes while the viscous glass provides for a compliant and self-healing seal. The glass composite seal may include fibers, powders, and/or beads of zirconium oxide, aluminum oxide, yttria-stabilized zirconia (YSZ), or mixtures thereof, to enhance the desirable properties of the glass composite seal.

  10. Determination of sulfur in steels by isotope dilution mass spectrometry after dissolution with sealed tube

    International Nuclear Information System (INIS)

    Watanabe, Kazuo

    1981-01-01

    The scaled tube dissolution technique was studied for the complete conversion of sulfur in steels to sulfate. Isotope dilution mass spectrometry was used for the determination of sulfur in the sulfate. Sample (0.5 g) was dissolved in nitric acid (7 ml) and hydrochloric acid (3 ml) in a scaled borosilicate glass tube on being heated above 180 0 C overnight. Nitrate ions were removed by repeated evaporation with hydrochloric acid. The residue was dissolved in hydrochloric acid. Sulfate was reduced with a mixture of hydrochloric, hydroiodic and hypophosphorous acids; hydrogen sulfide evolved was absorbed in cadmium acetate solution, then converted to silver sulfide, which was burned to sulfur dioxide in pure oxygen at low pressure, for isotopic analysis. Analytical blank in whole procedure was 0.8 μg of sulfur. This technique was applied to the determination of sulfur in NBS low alloy steels. The principal cause of low values obtained by the open beaker dissolution technique was evaporation losses of sulfur as sulfur dioxide during the dissolution. (author)

  11. Piston rod seal for a Stirling engine

    Science.gov (United States)

    Shapiro, Wilbur

    1984-01-01

    In a piston rod seal for a Stirling engine, a hydrostatic bearing and differential pressure regulating valve are utilized to provide for a low pressure differential across a rubbing seal between the hydrogen and oil so as to reduce wear on the seal.

  12. Neodymium conversion layers formed on zinc powder for improving electrochemical properties of zinc electrodes

    International Nuclear Information System (INIS)

    Zhu Liqun; Zhang Hui; Li Weiping; Liu Huicong

    2008-01-01

    Zinc powder, as active material of secondary alkaline zinc electrode, can greatly limit the performance of zinc electrode due to corrosion and dendritic growth of zinc resulting in great capacity-loss and short cycle life of the electrode. This work is devoted to modification study of zinc powder with neodymium conversion films coated directly onto it using ultrasonic immersion method for properties improvement of zinc electrodes. Scanning electron microscopy and other characterization techniques are applied to prove that neodymium conversion layers are distributing on the surface of modified zinc powder. The electrochemical performance of zinc electrodes made of such modified zinc powder is investigated through potentiodynamic polarization, potentiostatic polarization and cyclic voltammetry. The neodymium conversion films are found to have a significant effect on inhibition corrosion capability of zinc electrode in a beneficial way. It is also confirmed that the neodymium conversion coatings can obviously suppress dendritic growth of zinc electrode, which is attributed to the amelioration of deposition state of zinc. Moreover, the results of cyclic voltammetry reveal that surface modification of zinc powder enhances the cycle performance of the electrode mainly because the neodymium conversion films decrease the amounts of ZnO or Zn(OH) 2 dissolved in the electrolyte

  13. Folded membrane dialyzer with mechanically sealed edges

    Energy Technology Data Exchange (ETDEWEB)

    Markley, F.W.

    A semipermeable membrane is folded in accordion fashion to form a stack of pleats and the edges are sealed so as to isolate the opposite surfaces of the membrane. The stack is contained within a case that provides ports for flow of blood in contact with one surface of the membrane through channels formed by the pleats and also provides ports for flow of a dialysate through channels formed by the pleats in contact with the other surface of the membrane. The serpentine side edges of the membrane are sealed by a solidified plastic material, whereas effective mechanical means are provided to seal the end edges of the folded membrane. The mechanical means include a clamping strip which biases case sealing flanges into a sealed relationship with end portions of the membrane near the end edges, which portions extend from the stack and between the sealing flanges.

  14. Research, development and demonstration of nickel-zinc batteries for electric vehicle propulsion. Annual report, 1978

    Energy Technology Data Exchange (ETDEWEB)

    1979-10-01

    This is the first annual report of progress achieved under ANL Contract 31-109-38-4248. It covers the report period from 15 March 1978 to 15 August 1978. The nickel electrode development program is directed at the optimization of the electrical performance, specifically, in terms of increased cycle life. The work concentrated upon both the development of pilot plant facilities to produce nickel hydroxide and upon optimizing the manufacturing processes to produce nickel hydroxide which has high electrochemical utilization. The primary goal of the zinc electrode studies is to increase the cycle life of this electrode. This effort is primarily concentrating on the effect of additives upon shape change and cycle performance and on the mechanistic processes involved in the shape change. The separator effort has as its major goal the development of a low-cost separator which exhibits stability in the electrolyte, has uniform pores which are of a sufficiently small size to impede the growth of zinc dendrites, and exhibits low electrical resistance and good flexibility. The process itself is now optimized for pilot plant manufacture; hundreds of formulations have been produced and subsequently screened in both the laboratory and in actual cells. Promising formulations are presently being subjected to additional characterization tests and life cycles. The goal of the sealed cell studies is to determine the feasibility of sealed-cell operation. Large numbers of 20-Ah cells have been subjected to accelerated testing. These cells incorporated separator variations, active material additives, and internal design variations. Cycle lives up to 150 deep cycles were achieved. Cell failure modes are analyzed. 51 figures, 20 tables.

  15. 30 CFR 75.337 - Construction and repair of seals.

    Science.gov (United States)

    2010-07-01

    ... sealed areas. (b) Prior to sealing, the mine operator shall— (1) Remove insulated cables, batteries, and other potential electric ignition sources from the area to be sealed when constructing seals, unless it... after April 18, 2008, the seal at the lowest elevation shall have a corrosion-resistant, non-metallic...

  16. Zinc in human serum

    International Nuclear Information System (INIS)

    Kiilerich, S.

    1987-01-01

    The zinc ion is essential for the living organism. Many pathological conditions have been described as a consequence of zinc deficiency. As zinc constitutes less than 0.01 per cent of the body weight, it conventionally belongs to the group of trace elements. The method of atomic absorption spectrophotometry is used to measure the concentration of zinc in serum and urine from healthy persons. The assumptions of the method is discussed. The importance of proteinbinding, diet and the diurnal variation of serum zinc concentration is presented. Serum versus plasma zinc concentration is discussed. Reference serum zinc values from 104 normal subjects are given. Zinc in serum is almost entirely bound to proteins. A preliminary model for the estimation of the distribution of zinc between serum albumin and α 2 -macroglobulin is set up. This estimate has been examined by an ultracentrufugation method. The binding of zinc to a α 2 -macroglobulin in normal persons is appoximately 7 per cent, in patients with cirrhosis of the liver of alcoholic origin approximately 6 per cent, in patients with insulin dependent diabetes mellitus approximately 5 per cent, and in patients with chronic renal failure approximately 2 per cent. It is concluded, therefore, that for clinical purposes it is sufficient to use the concentration of total serum zinc corrected for the concentration of serum albumin. (author)

  17. Liquid-metal dip seal with pneumatic spring

    International Nuclear Information System (INIS)

    Poindexter, A.M.

    1977-01-01

    An improved liquid-metal dip seal for sealing the annulus between rotating plugs in the reactor vessel head of a liquid-metal fast-breeder nuclear reactor has two legs of differing widths communicating under a seal blade; the wide leg is also in communication with cover gas of the reactor and the narrow leg is also in communication with an isolated plug annulus above the seal. The annulus contains inert gas which acts as a pneumatic spring. Upon increasing cover gas pressure which depresses the level in the wide leg and greatly increases the level in the narrow leg, the pneumatic spring is compressed, and resists further level changes, thus preventing radioactive cover gas from bubbling through the seal

  18. Experimental toxoplasma gondii infection in grey seals (Halichoerus grypus)

    DEFF Research Database (Denmark)

    Gajadhar, A. A.; Measures, L.; Forbes, L. B.

    2004-01-01

    Laboratory-reared animals were used to assess the susceptibility of seals (Halichoerus grypus) to Toxoplasma gondii infection. Four seals were each orally inoculated with 100 or 10,000 oocysts of T. gondii (VEG strain), and another 4 seals served as negative controls. Occasionally, mild behavioral...... changes were observed in all inoculated seals but not in control animals. A modified agglutination test revealed the presence of antibodies to T. gondii in sera collected from inoculated seals and mice inoculated as controls. No evidence of the parasite was found on an extensive histological examination...... of seal tissues, and immunohistochemical staining of tissue sections from inoculated seals revealed a single tissue cyst in only 1 seal. Control mice inoculated with 10 oocysts from the same inoculum given to seals became serologically and histologically positive for T. gondii. Cats that were fed brain...

  19. Impact of residual elements on zinc quality in the production of zinc oxide

    Czech Academy of Sciences Publication Activity Database

    Luptáková, Natália; Dymáček, Petr; Pešlová, F.; Jurkovič, Z.; Barborák, O.; Stodola, J.

    2016-01-01

    Roč. 55, č. 3 (2016), s. 407-410 ISSN 0543-5846 Institutional support: RVO:68081723 Keywords : zinc * metallography * microstructure of zinc * zinc oxide * production of zinc oxide Subject RIV: JG - Metallurgy Impact factor: 0.959, year: 2014

  20. Cyclic AMP Pathway Activation and Extracellular Zinc Induce Rapid Intracellular Zinc Mobilization in Candida albicans

    Science.gov (United States)

    Kjellerup, Lasse; Winther, Anne-Marie L.; Wilson, Duncan; Fuglsang, Anja T.

    2018-01-01

    Zinc is an essential micronutrient, required for a range of zinc-dependent enzymes and transcription factors. In mammalian cells, zinc serves as a second messenger molecule. However, a role for zinc in signaling has not yet been established in the fungal kingdom. Here, we used the intracellular zinc reporter, zinbo-5, which allowed visualization of zinc in the endoplasmic reticulum and other components of the internal membrane system in Candida albicans. We provide evidence for a link between cyclic AMP/PKA- and zinc-signaling in this major human fungal pathogen. Glucose stimulation, which triggers a cyclic AMP spike in this fungus resulted in rapid intracellular zinc mobilization and this “zinc flux” could be stimulated with phosphodiesterase inhibitors and blocked via inhibition of adenylate cyclase or PKA. A similar mobilization of intracellular zinc was generated by stimulation of cells with extracellular zinc and this effect could be reversed with the chelator EDTA. However, zinc-induced zinc flux was found to be cyclic AMP independent. In summary, we show that activation of the cyclic AMP/PKA pathway triggers intracellular zinc mobilization in a fungus. To our knowledge, this is the first described link between cyclic AMP signaling and zinc homeostasis in a human fungal pathogen. PMID:29619016

  1. Low torque hydrodynamic lip geometry for rotary seals

    Science.gov (United States)

    Dietle, Lannie L.; Schroeder, John E.

    2015-07-21

    A hydrodynamically lubricating geometry for the generally circular dynamic sealing lip of rotary seals that are employed to partition a lubricant from an environment. The dynamic sealing lip is provided for establishing compressed sealing engagement with a relatively rotatable surface, and for wedging a film of lubricating fluid into the interface between the dynamic sealing lip and the relatively rotatable surface in response to relative rotation that may occur in the clockwise or the counter-clockwise direction. A wave form incorporating an elongated dimple provides the gradual convergence, efficient impingement angle, and gradual interfacial contact pressure rise that are conducive to efficient hydrodynamic wedging. Skewed elevated contact pressure zones produced by compression edge effects provide for controlled lubricant movement within the dynamic sealing interface between the seal and the relatively rotatable surface, producing enhanced lubrication and low running torque.

  2. Reactivation in vitro of zinc-requiring apo-enzymes by rat liver zinc-thionein

    OpenAIRE

    Udom, Albert O.; Brady, Frank O.

    1980-01-01

    The ability of rat liver zinc-thionein to donate its metal to the apo-enzymes of the zinc enzymes horse liver alcohol dehydrogenase, yeast aldolase, thermolysin, Escherichia coli alkaline phosphatase and bovine erythrocyte carbonic anhydrase was investigated. Zinc-thionein was as good as, or better than, ZnSO4, Zn(CH3CO2)2 or Zn(NO3)2 in donating its zinc to these apo-enzymes. Apo-(alcohol dehydrogenase) could not be reactivated by zinc salts or by zinc-thionein. Incubation of the other apo-e...

  3. Turbine and Structural Seals Team Facilities

    Data.gov (United States)

    Federal Laboratory Consortium — Seals Team Facilities conceive, develop, and test advanced turbine seal concepts to increase efficiency and durability of turbine engines. Current projects include...

  4. Tamper-indicating devices and safeguards seals evaluation test report

    International Nuclear Information System (INIS)

    Horton, P.R.V.; Waddoups, I.G.

    1993-12-01

    Sandia National Laboratories was asked to evaluate the seals used as tamper-indicating devices (TIDs) at DOE facilities. Initially, a survey determined what seal manufacturers were being used and what similar seal types were available. Once the required specifications for TIDs were defined, a test plan measured the currently available seals against the requirements. Environmental and physical type tests stressed the seals under two broad categories: (1) handling durability and (2) tamper resistance. Results of the testing provide comparative ratings for the various seals, recommendations for using currently available seals, and a new tamper-indicating technology

  5. Design and research of seal structure for thermocouple column assembly

    International Nuclear Information System (INIS)

    Rao Qiqi; Li Na; Zhao Wei; Ma Zhigang

    2015-01-01

    The new seal structure was designed to satisfy the function of thermocouple column assembly and the reactor structure. This seal structure uses the packing graphite ring and adopts the self-sealing principle. Cone angle is brought to the seal face of seal structure which is conveniently to assembly and disassembly. After the sealing principle analysis and stress calculation of graphite ring which adopt the cone angle, the cone angle increases the radial force of seal structure and improves the seal effect. The stress analysis result shows the seal structure strength satisfies the regulation requirement. The cold and hot function test results shows the sealing effect is good, and the design requirement is satisfied. (authors)

  6. Development of sealing plug for sweep gas line

    International Nuclear Information System (INIS)

    Kikuchi, Taiji; Yamada, Hirokazu; Saitoh, Takashi; Nakamichi, Masaru; Tsuchiya, Kunihiko; Kawamura, Hiroshi

    2004-03-01

    On the irradiation capsule for neutron irradiation test of the tritium breeder, the sealing plug is necessary to prevent a leak of tritium gas when the tritium breeder is picked up from the irradiation capsule after irradiation test. However, the general valve and plug cannot apply to sealing of the sweep gas line because of the following factors, the neutron irradiation effect, limited space in the irradiation capsule, high sealing efficiency, simple method and operation for control. Therefore, the sealing plug for sweep gas line has to be developed. This paper reports the development of the sealing plug for sweep gas line and the operating procedure of the sealing plug in the irradiation capsule. (author)

  7. Development, production, and application of sealed-off copper and gold vapour lasers

    International Nuclear Information System (INIS)

    Lyabin, Nikolai A; Chursin, A D; Ugol'nikov, S A; Koroleva, M E; Kazaryan, M A

    2001-01-01

    An analysis is made of the current state of the art of scientific and engineering advances in the field of repetitively pulsed self-heating metal vapour (copper and gold) lasers based on industrial, sealed-off, high-temperature, metalceramic and metal-glass active elements. The major applications of these lasers are discussed. The energy, spatial, and time characteristics of the lasers and their dependence on the parameters and construction of the laser active elements (tubes) and optical resonators are considered. The ways for the development of new high-power industrial laser active elements with a high efficiency (1 - 2%) and a service life of 500 - 1000 h are analysed. An average output power of 80 W was realised with a laser tube 150 cm in length and 32 mm in diameter. When the pumping efficiency is improved by raising the voltage to 30 - 35 kV, this system in a copper vapour laser will allow an output power of 100 W to be obtained with one active element. The characteristics of industrial versions of metal vapour lasers manufactured in different countries are compared and discussed. (invited paper)

  8. 2007 NASA Seal/Secondary Air System Workshop. Volume 1

    Science.gov (United States)

    Steinetz, Bruce M.; Hendricks, Robert C.; Delgado, Irebert

    2008-01-01

    The 2007 NASA Seal/Secondary Air System workshop covered the following topics: (i) Overview of NASA's new Orion project aimed at developing a new spacecraft that will fare astronauts to the International Space Station, the Moon, Mars, and beyond; (ii) Overview of NASA's fundamental aeronautics technology project; (iii) Overview of NASA Glenn s seal project aimed at developing advanced seals for NASA's turbomachinery, space, and reentry vehicle needs; (iv) Reviews of NASA prime contractor, vendor, and university advanced sealing concepts, test results, experimental facilities, and numerical predictions; and (v) Reviews of material development programs relevant to advanced seals development. Turbine engine studies have shown that reducing seal leakage as well as high-pressure turbine (HPT) blade tip clearances will reduce fuel burn, lower emissions, retain exhaust gas temperature margin, and increase range. Turbine seal development topics covered include a method for fast-acting HPT blade tip clearance control, noncontacting low-leakage seals, intershaft seals, and a review of engine seal performance requirements for current and future Army engine platforms.

  9. High pressure, high current, low inductance, high reliability sealed terminals

    Science.gov (United States)

    Hsu, John S [Oak Ridge, TN; McKeever, John W [Oak Ridge, TN

    2010-03-23

    The invention is a terminal assembly having a casing with at least one delivery tapered-cone conductor and at least one return tapered-cone conductor routed there-through. The delivery and return tapered-cone conductors are electrically isolated from each other and positioned in the annuluses of ordered concentric cones at an off-normal angle. The tapered cone conductor service can be AC phase conductors and DC link conductors. The center core has at least one service conduit of gate signal leads, diagnostic signal wires, and refrigerant tubing routed there-through. A seal material is in direct contact with the casing inner surface, the tapered-cone conductors, and the service conduits thereby hermetically filling the interstitial space in the casing interior core and center core. The assembly provides simultaneous high-current, high-pressure, low-inductance, and high-reliability service.

  10. Comparison of correlation algorithms for identifying ultrasonic seals

    International Nuclear Information System (INIS)

    Beer, C.L.; McKenzie, J.M.

    1991-01-01

    Ultrasonic seals are used on reactor fuel assemblies for international safeguards applications. The seals are read by a Seal Pattern Reader to obtain a discrete digital signature that is unique to each seal. The signature is used to determine the identity and integrity of the seals such that accountability and integrity of the nuclear fuel assemblies can be addressed. A correlation coefficient is calculated between the signature obtained at the time of inspection and a stored reference signature, yielding a number between negative one and one. Numbers close to one indicate a high probability that the two signatures represent the same seal. Data from two seals were studied, the Atomic Energy of Canada Limited Random Coil (ARC) seal and the JRC-Ispra VAK-III seal. Currently, correlation coefficients are obtained using data in the time or spatial domain, respectively. An approach is proposed in which the correlation coefficients are obtained from the Fourier transforms of the data. This paper reports that the objective of the study was to perform independent experiments on available ARC and VAK-III data to determine the advantages, if any, of transforming the data to the frequency spectrum prior to performing the correlation calculation. The results indicate definite advantages can be obtained

  11. Effect of sealing on the morphology of anodized aluminum oxide

    International Nuclear Information System (INIS)

    Hu, Naiping; Dong, Xuecheng; He, Xueying; Browning, James F.; Schaefer, Dale W.

    2015-01-01

    Highlights: • We explored structural change of anodizing aluminum oxide induced by sealing. • All sealing methods decrease pore size as shown by X-ray/neutron scattering. • Cold sealing and hot water sealing do not alter the aluminum oxide framework. • Hot nickel acetate sealing both fills the pores and deposits on air oxide interface. • Samples with hot nickel acetate sealing outperform other sealing methods. - Abstract: Ultra-small angle X-ray scattering (USAXS), small-angle neutron scattering (SANS), X-ray reflectometry (XRR) and neutron reflectometry (NR) were used to probe structure evolution induced by sealing of anodized aluminum. While cold nickel acetate sealing and hot-water sealing decrease pore size, these methods do not alter the cylindrical porous framework of the anodic aluminum oxide layer. Hot nickel acetate both fills the pores and deposits on the air surface (air–oxide interface), leading to low porosity and small mean pore radius (39 Å). Electrochemical impedance spectroscopy and direct current polarization show that samples sealed by hot nickel acetate outperform samples sealed by other sealing methods

  12. Ergonomics and safety of manual bag sealing.

    NARCIS (Netherlands)

    Groot, M.D. de; Bosch, T.; Eikhout, S.M.; Vink, P.

    2005-01-01

    A variety of seals is used to close bags. Each seal has advantages and disadvantages. For shop assistants sealing bags could be a repetitive physically demanding action. Opening and closing the bags again can cause some discomfort or annoyance for consumers. Besides, it is an activity which can

  13. Transformation of zinc hydroxide chloride monohydrate to crystalline zinc oxide.

    Science.gov (United States)

    Moezzi, Amir; Cortie, Michael; McDonagh, Andrew

    2016-04-25

    Thermal decomposition of layered zinc hydroxide double salts provides an interesting alternative synthesis for particles of zinc oxide. Here, we examine the sequence of changes occurring as zinc hydroxide chloride monohydrate (Zn5(OH)8Cl2·H2O) is converted to crystalline ZnO by thermal decomposition. The specific surface area of the resultant ZnO measured by BET was 1.3 m(2) g(-1). A complicating and important factor in this process is that the thermal decomposition of zinc hydroxide chloride is also accompanied by the formation of volatile zinc-containing species under certain conditions. We show that this volatile compound is anhydrous ZnCl2 and its formation is moisture dependent. Therefore, control of atmospheric moisture is an important consideration that affects the overall efficiency of ZnO production by this process.

  14. Influence of soil zinc concentrations on zinc sensitivity and functional diversity of microbial communities

    International Nuclear Information System (INIS)

    Lock, K.; Janssen, C.R.

    2005-01-01

    Pollution induced community tolerance (PICT) is based on the phenomenon that toxic effects reduce survival of the most sensitive organisms, thus increasing community tolerance. Community tolerance for a contaminant is thus a strong indicator for the presence of that contaminant at the level of adverse concentrations. Here we assessed PICT in 11 soils contaminated with zinc runoff from galvanised electricity pylons and 11 reference soils sampled at 10 m distance from these pylons. Using PICT, the influence of background concentration and bioavailability of zinc on zinc sensitivity and functional diversity of microbial communities was assessed. Zinc sensitivity of microbial communities decreased significantly with increasing zinc concentrations in pore water and calcium chloride extracted fraction while no significant relationship was found with total zinc concentration in the soil. It was also found that functional diversity of microbial communities decreased with increasing zinc concentrations, indicating that increased tolerance is indeed an undesirable phenomenon when environmental quality is considered. The hypothesis that zinc sensitivity of microbial communities is related to background zinc concentration in pore water could not be confirmed. - Zinc sensitivity of microbial communities and functional diversity decrease with increasing zinc concentration in the pore water

  15. Electrochemical synthesis and characterization of zinc carbonate and zinc oxide nanoparticles

    Science.gov (United States)

    Pourmortazavi, Seied Mahdi; Marashianpour, Zahra; Karimi, Meisam Sadeghpour; Mohammad-Zadeh, Mohammad

    2015-11-01

    Zinc oxide and its precursor i.e., zinc carbonate is widely utilized in various fields of industry, especially in solar energy conversion, optical, and inorganic pigments. In this work, a facile and clean electrodeposition method was utilized for the synthesis of zinc carbonate nanoparticles. Also, zinc oxide nanoparticles were produced by calcination of the prepared zinc carbonate powder. Zinc carbonate nanoparticles with different sizes were electrodeposited by electrolysis of a zinc plate as anode in the solution of sodium carbonate. It was found that the particle size of zinc carbonate might be tuned by process parameters, i.e., electrolysis voltage, carbonate ion concentration, solvent composition and stirring rate of the electrolyte solution. An orthogonal array design was utilized to identify the optimum experimental conditions. The experimental results showed that the minimum size of the electrodeposited ZnCO3 particles is about 24 nm whereas the maximum particle size is around 40 nm. The TG-DSC studies of the nanoparticles indicated that the main thermal degradation of ZnCO3 occurs in two steps over the temperature ranges of 150-250 and 350-400 °C. The electrosynthesized ZnCO3 nanoparticles were calcined at the temperature of 600 °C to prepare ZnO nanoparticles. The prepared ZnCO3 and ZnO nanoparticles were characterized by SEM, X-ray diffraction (XRD), and FT-IR techniques.

  16. Dampers for Stationary Labyrinth Seals

    Science.gov (United States)

    El-Aini, Yehia; Mitchell, William; Roberts, Lawrence; Montgomery, Stuart; Davis, Gary

    2011-01-01

    Vibration dampers have been invented that are incorporated as components within the stationary labyrinth seal assembly. These dampers are intended to supplement other vibration-suppressing features of labyrinth seals in order to reduce the incidence of high-cycle-fatigue failures, which have been known to occur in the severe vibratory environments of jet engines and turbopumps in which labyrinth seals are typically used. A vibration damper of this type includes several leaf springs and/or a number of metallic particles (shot) all held in an annular seal cavity by a retaining ring. The leaf springs are made of a spring steel alloy chosen, in conjunction with design parameters, to maintain sufficient preload to ensure effectiveness of damping at desired operating temperatures. The cavity is vented via a small radial gap between the retaining ring and seal housing. The damping mechanism is complex. In the case of leaf springs, the mechanism is mainly friction in the slippage between the seal housing and individual dampers. In the case of a damper that contains shot, the damping mechanism includes contributions from friction between individual particles, friction between particles and cavity walls, and dissipation of kinetic energy of impact. The basic concept of particle/shot vibration dampers has been published previously; what is new here is the use of such dampers to suppress traveling-wave vibrations in labyrinth seals. Damping effectiveness depends on many parameters, including, but not limited to, coefficient of friction, mode shape, and frequency and amplitude of vibrational modes. In tests, preloads of the order of 6 to 15 lb (2.72 to 6.8 kilograms) per spring damper were demonstrated to provide adequate damping levels. Effectiveness of shot damping of vibrations having amplitudes from 20 to 200 times normal terrestrial gravitational acceleration (196 to 1,960 meters per square second) and frequencies up to 12 kHz was demonstrated for shot sizes from 0.032 to

  17. The relative efficiency of zinc carriers on growth and zinc nutrition of corn

    International Nuclear Information System (INIS)

    Prasad, B.; Sinha, K.

    1981-01-01

    A comparison of different zinc carriers showed that application of Zn-DTPA, Zn-EDTA, Zn-fulvate and ZnSO 4 significantly increased the dry matter yield and zinc uptake by corn over the control treatment where no zinc was applied. The chelates in particular enhanced to a greater extent the uptake of both native and applied sources than that observed with ZnSO 4 as the zinc carrier. Both the dry matter yield and zinc uptake by corn showed a positive and significant relationship with self-diffusion coefficient of zinc showing thereby that diffusion contributed mainly the supply of Zn from the ambient soil matrix to plant roots. The effectiveness of the chelates varied depending on their capacity to retain Zn in a soluble form in the soil solution. It is evident that zinc nutrition of plants in alkaline and calcareous soils can be more effectively regulated by both synthetic and natural chelates or organic manures which contain substantial amount of complexed zinc. (orig.)

  18. Ductile alloys for sealing modular component interfaces

    Science.gov (United States)

    Marra, John J.; Wessell, Brian J.; James, Allister W.; Marsh, Jan H.; Gear, Paul J.

    2017-08-08

    A vane assembly (10) having: an airfoil (12) and a shroud (14) held together without metallurgical bonding there between; a channel (22) disposed circumferentially about the airfoil (12), between the airfoil (12) and the shroud (14); and a seal (20) disposed in the channel (22), wherein during operation of a turbine engine having the vane assembly (10) the seal (20) has a sufficient ductility such that a force generated on the seal (20) resulting from relative movement of the airfoil (12) and the shroud (14) is sufficient to plastically deform the seal (20).

  19. Ceramic-glass-metal seal by microwave heating

    Science.gov (United States)

    Meek, Thomas T.; Blake, Rodger D.

    1985-01-01

    A method for producing a ceramic-glass-metal seal by microwaving mixes a slurry of glass sealing material and coupling agent and applies same to ceramic and metal workpieces. The slurry and workpieces are then insulated and microwaved at a power, time and frequency sufficient to cause a liquid phase reaction in the slurry. The reaction of the glass sealing material forms a chemically different seal than that which would be formed by conventional heating because it is formed by diffusion rather than by wetting of the reactants.

  20. Bingham Sealing and Application in Vacuum Clamping

    Science.gov (United States)

    Yao, S. M.; Teo, Wee Kin; Geng, Zunmin; Turner, Sam; Ridgway, Keith

    2011-12-01

    Vacuum clamping is extensively used in shell machining. In this paper a Bingham Sealing (BS) is presented and formulized based on Bingham plastic performance. The sealing capability of BS is evaluated in various cases. A new Bingham plastic is developed and the yield stress is measured. The performances of "O"ring sealing and BS with the developed Bingham plastic are compared to the static experiment. In this experiment the same vacuum is achieved and the distortion of the blade with BS is better than that with "O" ring sealing.

  1. Bingham Sealing and Application in Vacuum Clamping

    International Nuclear Information System (INIS)

    Yao, S M; Teo, Wee Kin; Geng Zunmin; Turner, Sam; Ridgway, Keith

    2011-01-01

    Vacuum clamping is extensively used in shell machining. In this paper a Bingham Sealing (BS) is presented and formulized based on Bingham plastic performance. The sealing capability of BS is evaluated in various cases. A new Bingham plastic is developed and the yield stress is measured. The performances of Or ing sealing and BS with the developed Bingham plastic are compared to the static experiment. In this experiment the same vacuum is achieved and the distortion of the blade with BS is better than that with 'O' ring sealing.

  2. Tunnel sealing: concept and feasibility evidence

    International Nuclear Information System (INIS)

    Brenner, R.P.; Eppinger, G.; Mettler, K.

    1991-01-01

    This report discusses first the aim and purpose of tunnel seals as well as the requirements which should be satisfied. The basic seal concept is a zoned plug consisting of key zones and intermediate zones. The key zones act as barrier elements and will be placed into sections of competent and sound rock. The main function of the intermediate zones is that of a support and the requirements for sealing efficiency may be somewhat relaxed. Three sealing concepts have been devised for both the key zones and the intermediate zones. They differ in the materials used for the seal and in the placement method. For the key zones highly compacted bentonite is recommended, but also cement-based materials, such as standard concrete or prepact concrete are considered suitable. For the intermediate zones, the use of pumped concrete with subsequent grouting of the roof zone is favourable, but also a combination of concrete with a sand/gravel mixture or with properly compacted excavation material is feasible. The concepts introduced can all be realized by conventional tunnelling methods. Excavation by tunnel boring machine is most advantageous as it minimizes disturbance of the rock caused by the cavity-forming process. By employing simple material models, it can be shown that the depth of the excavation disturbed zone can be minimized if support of the tunnel is provided as early as possible after excavation. The cutting of a groove in the tunnel wall along the key zone can further contribute to reduce the depth of the excavation-disturbed zone. In order to ensure the quality of a seal, the quantities of the materials used can be checked and the work procedures to place the seal can be supervised. For the latter the experiences obtained from a large-scale test should be available. Finally, it is also shown that when considering safety analytical aspects, the proposed sealing concepts represent adequate solutions in spite of the probably increased permeability in the excavation

  3. Zinc triggers microglial activation.

    Science.gov (United States)

    Kauppinen, Tiina M; Higashi, Youichirou; Suh, Sang Won; Escartin, Carole; Nagasawa, Kazuki; Swanson, Raymond A

    2008-05-28

    Microglia are resident immune cells of the CNS. When stimulated by infection, tissue injury, or other signals, microglia assume an activated, "ameboid" morphology and release matrix metalloproteinases, reactive oxygen species, and other proinflammatory factors. This innate immune response augments host defenses, but it can also contribute to neuronal death. Zinc is released by neurons under several conditions in which microglial activation occurs, and zinc chelators can reduce neuronal death in animal models of cerebral ischemia and neurodegenerative disorders. Here, we show that zinc directly triggers microglial activation. Microglia transfected with a nuclear factor-kappaB (NF-kappaB) reporter gene showed a severalfold increase in NF-kappaB activity in response to 30 microm zinc. Cultured mouse microglia exposed to 15-30 microm zinc increased nitric oxide production, increased F4/80 expression, altered cytokine expression, and assumed the activated morphology. Zinc-induced microglial activation was blocked by inhibiting NADPH oxidase, poly(ADP-ribose) polymerase-1 (PARP-1), or NF-kappaB activation. Zinc injected directly into mouse brain induced microglial activation in wild-type mice, but not in mice genetically lacking PARP-1 or NADPH oxidase activity. Endogenous zinc release, induced by cerebral ischemia-reperfusion, likewise induced a robust microglial reaction, and this reaction was suppressed by the zinc chelator CaEDTA. Together, these results suggest that extracellular zinc triggers microglial activation through the sequential activation of NADPH oxidase, PARP-1, and NF-kappaB. These findings identify a novel trigger for microglial activation and a previously unrecognized mechanism by which zinc may contribute to neurological disorders.

  4. HMSRP Hawaiian Monk Seal Crittercam video

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — This project investigates foraging behavior of Hawaiian monk seals by conducting telemetry studies. During these studies, live seals are instrumented with dive...

  5. Effects of dietary supplementation with tribasic zinc sulfate or zinc sulfate on growth performance, zinc content and expression of zinc transporters in young pigs.

    Science.gov (United States)

    Deng, Bo; Zhou, Xihong; Wu, Jie; Long, Ciming; Yao, Yajun; Peng, Hongxing; Wan, Dan; Wu, Xin

    2017-10-01

    An experiment was conducted to compare the effects of zinc sulfate (ZS) and tribasic zinc sulfate (TBZ) as sources of supplemental zinc on growth performance, serum zinc (Zn) content and messenger RNA (mRNA) expression of Zn transporters (ZnT1/ZnT2/ZnT5/ZIP4/DMT1) of young growing pigs. A total of 96 Duroc × Landrace × Yorkshire pigs were randomly allotted to two treatments and were fed a basal diet supplemented with 100 mg/kg Zn from either ZS or TBZ for 28 days. Feed : gain ratio in pigs fed TBZ were lower (P zinc transporter in either duodenum or jejunum of pigs fed TBZ were higher (P < 0.05) than pigs fed ZS. These results indicate that TBZ is more effective in serum Zn accumulation and intestinal Zn absorption, and might be a potential substitute for ZS in young growing pigs. © 2017 Japanese Society of Animal Science.

  6. Leak detection of KNI seals

    International Nuclear Information System (INIS)

    Baranyai, G.; Peter, A.; Windberg, P.

    1990-03-01

    In Unit 3 and 4 of the Paks Nuclear Power Plant, Hungary, KNI type seals are used as lead-throughs with conical nickel sealing rings. Their failure can be critical for the operation of the reactor. An Acoustical Leak Detection System (ALDS) was constructed and tested for the operational testing of the seals. Some individual papers are presented in this collection on the calibration and testing of the ALDS intended to be placed on the top of the reactor vessels. The papers include simulation measurements of Unit 3 of NPP, laboratory experiments, evaluation of measurements, and further development needs with the ALDS. (R.P.) 50 figs.; 19 tabs

  7. Unification of reactor elastomeric sealing based on material

    International Nuclear Information System (INIS)

    Sinha, N.K.; Raj, Baldev

    2012-01-01

    The unification of elastomeric sealing applications of Indian nuclear reactors based on a few qualified fluoroelastomer/perfluoroelastomer compounds and standardized approaches for finite element analysis (FEA) based design, manufacturing process and antifriction coatings is discussed. It is shown that the advance polymer architecture based Viton ® formulation developed for inflatable seals of 500 MWe Prototype Fast Breeder Reactor (PFBR) and its four basic variations can encompass other sealing applications of PFBR with minimum additional efforts on development and validation. Changing the blend ratio of Viton ® GBL 200S and 600S in inflatable seal formulation could extend its use to Pressurized Heavy Water Reactors (PHWRs). The higher operating temperature of Advanced Heavy Water Reactor (AHWR) seals expands the choice to perfluoroelastomers. FEA based on plane-strain/axisymmetric modeling (with Mooney–Rivlin as the basic constitutive model), seal manufacture by cold feed extrusion and injection molding as well as plasma Teflon-like coating belonging to two variations obtained from the development of inflatable seals provide the necessary standardization for unification. The gains in simplification of design, development and operation of seals along with the enhancements of safety and reliability are expected to be substantial.

  8. Availability of native and fertilizer zinc in some Indian soils: studies with 65Zinc

    International Nuclear Information System (INIS)

    Chaudhury, J.; Deb, D.L.

    1979-01-01

    Isotopically exchangeable zinc (Et values) was determined by different methods in some soils having pH(H 2 O) varying from 3.05 to 8.40 using 65 Zn. The Et values obtained using different extractants showed significant correlation with available zinc, organic carbon and soil pH. The recovery of applied zinc in the aqueous phase was less than one percent in most of the soils having pH higher than 7.0. Application of zinc with complexing agents like DTPA and EDTA increased the recovery of applied zinc in the solution to about 95 percent. Soil pH, organic C and DTPA extractable zinc showed significant relationship with the recovery of applied zinc under different treatments. Use of EDTA and DTPA extractants reduced the zinc buffering capacity of soil to a value less than one, irrespective of the initial pH of the soil, whereas the values were comparatively higher in presence of different levels of zinc carrier. (auth.)

  9. 65Zinc and endogenous zinc content and distribution in islets in relationship to insulin content

    International Nuclear Information System (INIS)

    Figlewicz, D.P.; Forhan, S.E.; Hodgson, A.T.; Grodsky, G.M.

    1984-01-01

    Uptake of 65 Zn and distribution of 65 Zn, total zinc, and insulin were measured in rat islets and islet granules under different conditions of islet culture. Specific activity of islet zinc ( 65 Zn/zinc) was less than 15% that of extracellular zinc even after 48 h. In contrast, once in the islet, 65 Zn approached 70% of equilibrium with granular zinc in 24 h and apparent equilibrium by 48 h. During a 24-h culture, at either high or low glucose, reduction of both islet zinc and insulin occurred. However, zinc depletion was greater than that predicted if zinc loss was proportional to insulin depletion and occurred only from the granular compartment, which represents only one third of the total islet zinc. Extension of culture to 48 h caused additional insulin depletion, but islet zinc was unchanged. Omission of calcium during the 48-h culture caused a predicted increase in insulin retention, presumably by inhibiting secretion; however, zinc retention was not increased proportionately. Pretreatment of rats with tolbutamide caused a massive depletion of insulin stored in isolated islets, with little change in total islet zinc; subsequent culture of these islets resulted in a greater loss of granular zinc than predicted from the small loss of granular insulin. None of the conditions tested affected the percentage of either 65 Zn or total zinc that was distributed in the islet granules. Results show that zinc exists in a metabolically labile islet compartment(s) as well as in secretory granules; and extra-granular zinc, although not directly associated with insulin storage, may act as a reservoir for granular zinc and may regulate insulin synthesis, storage, and secretion in ways as yet unknown

  10. The Potential for Zinc Stable Isotope Techniques and Modelling to Determine Optimal Zinc Supplementation

    Directory of Open Access Journals (Sweden)

    Cuong D. Tran

    2015-05-01

    Full Text Available It is well recognised that zinc deficiency is a major global public health issue, particularly in young children in low-income countries with diarrhoea and environmental enteropathy. Zinc supplementation is regarded as a powerful tool to correct zinc deficiency as well as to treat a variety of physiologic and pathologic conditions. However, the dose and frequency of its use as well as the choice of zinc salt are not clearly defined regardless of whether it is used to treat a disease or correct a nutritional deficiency. We discuss the application of zinc stable isotope tracer techniques to assess zinc physiology, metabolism and homeostasis and how these can address knowledge gaps in zinc supplementation pharmacokinetics. This may help to resolve optimal dose, frequency, length of administration, timing of delivery to food intake and choice of zinc compound. It appears that long-term preventive supplementation can be administered much less frequently than daily but more research needs to be undertaken to better understand how best to intervene with zinc in children at risk of zinc deficiency. Stable isotope techniques, linked with saturation response and compartmental modelling, also have the potential to assist in the continued search for simple markers of zinc status in health, malnutrition and disease.

  11. The Potential for Zinc Stable Isotope Techniques and Modelling to Determine Optimal Zinc Supplementation

    Science.gov (United States)

    Tran, Cuong D.; Gopalsamy, Geetha L.; Mortimer, Elissa K.; Young, Graeme P.

    2015-01-01

    It is well recognised that zinc deficiency is a major global public health issue, particularly in young children in low-income countries with diarrhoea and environmental enteropathy. Zinc supplementation is regarded as a powerful tool to correct zinc deficiency as well as to treat a variety of physiologic and pathologic conditions. However, the dose and frequency of its use as well as the choice of zinc salt are not clearly defined regardless of whether it is used to treat a disease or correct a nutritional deficiency. We discuss the application of zinc stable isotope tracer techniques to assess zinc physiology, metabolism and homeostasis and how these can address knowledge gaps in zinc supplementation pharmacokinetics. This may help to resolve optimal dose, frequency, length of administration, timing of delivery to food intake and choice of zinc compound. It appears that long-term preventive supplementation can be administered much less frequently than daily but more research needs to be undertaken to better understand how best to intervene with zinc in children at risk of zinc deficiency. Stable isotope techniques, linked with saturation response and compartmental modelling, also have the potential to assist in the continued search for simple markers of zinc status in health, malnutrition and disease. PMID:26035248

  12. Machine Vision Inspection of Polymeric Traypack Seal Areas

    National Research Council Canada - National Science Library

    Coburn, John

    2002-01-01

    .... Since entrapped matter can lead to open seals, defects, and seal anomalies, a method of measurement for seal area contamination is useful in quantifying effects of filler changes, line speeds, and product formulations...

  13. Effect of zinc from zinc sulfate on trace mineral concentrations of milk ...

    African Journals Online (AJOL)

    PRECIOUS

    2009-11-16

    Nov 16, 2009 ... It suggests that supplementation of ewes diet with zinc sulfate could be an effective way to increase zinc ... alkaline phosphates activity. Zinc supplements were .... Similar results have been reported previously when dairy cows.

  14. Reactor coolant pump shaft seal behavior during station blackout

    International Nuclear Information System (INIS)

    Kittmer, C.A.; Wensel, R.G.; Rhodes, D.B.; Metcalfe, R.; Cotnam, B.M.; Gentili, H.; Mings, W.J.

    1985-04-01

    A testing program designed to provide fundamental information pertaining to the behavior of reactor coolant pump (RCP) shaft seals during a postulated nuclear power plant station blackout has been completed. One seal assembly, utilizing both hydrodynamic and hydrostatic types of seals, was modeled and tested. Extrusion tests were conducted to determine if seal materials could withstand predicted temperatures and pressures. A taper-face seal model was tested for seal stability under conditions when leaking water flashes to steam across the seal face. Test information was then used as the basis for a station blackout analysis. Test results indicate a potential problem with an elastomer material used for O-rings by a pump vendor; that vendor is considering a change in material specification. Test results also indicate a need for further research on the generic issue of RCP seal integrity and its possible consideration for designation as an unresolved safety issue

  15. Evolution of the zinc compound nanostructures in zinc acetate single-source solution

    International Nuclear Information System (INIS)

    Wang Ying; Li Yinhua; Zhou Zhengzhi; Zu Xihong; Deng Yulin

    2011-01-01

    A series of nanostructured zinc compounds with different nanostructures such as nanobelts, flake-like, flower-like, and twinning crystals was synthesized using zinc acetate (Zn(Ac) 2 ) as a single-source. The evolution of the zinc compounds from layered basic zinc acetate (LBZA) to bilayered basic zinc acetate (BLBZA) and twinned ZnO nano/microcrystal was studied. The low-angle X-ray diffraction spectra indicate the layered spacing is 1.34 and 2.1 nm for LBZA and BLBZA, respectively. The Fourier transform infrared (FTIR) spectra results confirmed that the bonding force of acetate anion with zinc cations decreases with the phase transformation from Zn(Ac) 2 to BLBZA, and finally to LBZA. The OH − groups gradually replaced the acetate groups coordinated to the matrix zinc cation, and the acetate groups were released completely. Finally, the Zn(OH) 2 and ZnO were formed at high temperature. The conversion process from Zn(Ac) 2 to ZnO with release of acetate anions can be described as Zn(Ac) 2 → BLBZA → LBZA → Zn(OH) 2 → ZnO.

  16. Effects of dietary zinc status on seizure susceptibility and hippocampal zinc content in the El (epilepsy) mouse.

    Science.gov (United States)

    Fukahori, M; Itoh, M

    1990-10-08

    The effects of dietary zinc status on the development of convulsive seizures, and zinc concentrations in discrete hippocampal areas and other parts of the limbic system were studied in the El mouse model receiving zinc-adequate, zinc-deficient or zinc-loaded diets. Seizure susceptibility of the El mouse was increased by zinc deficiency, and decreased by zinc loading, while an adequate diet had no effect. Zinc loading was accompanied by a marked increase in hippocampal zinc content in the El mouse. Conversely, hippocampal zinc content declined in the El mouse fed a zinc-deficient diet. These results suggest that zinc may have a preventive effect on the development of seizures in the El mouse, and hippocampal zinc may play an important role in the pathophysiology of convulsive seizures of epilepsy.

  17. Development of a high temperature ceramic-to-metal seal for Air Force Weapons Laboratory Laser

    Science.gov (United States)

    Honnell, R. E.; Stoddard, S. D.

    1987-03-01

    Procedures were developed for fabricating vacuum tight metal-to-ceramic ring seals between Inconel 625 and MgO-3 wt % Y2O3 tubes metallized with a calcia-alumina-silica glass (CaO-29 wt % Al2O3-35 wt % SiO2) containing 50 vol % molybdenum filler. Palniro No. 1 (Au-25 wt % Pd-25 wt % Ni) was found to be the most reliable braze for joining Inconel to metallized MgO-3 wt % Y2O3 bodies. The reliabilities of the processing procedures and the material systems were demonstrated. A prototype electrical feedthrough was fabricated for 1173 K operation in air or vacuum.

  18. The glass-like glazed coating made of cathode-ray tube faceplates cullet

    Directory of Open Access Journals (Sweden)

    N.І. Zavgorodnya

    2016-05-01

    Full Text Available The tendency of the current time is to find ways of expedient municipal solid waste recycling as a secondary raw material with similar physicochemical and mechanical characteristics for the purpose of efficient use of resources and reduction of harmful impact on the environment. Due to the termination the production of monitors and television sets with cathode-ray tubes, a significant part of them is grow out of use in the form of dimensional waste. Kinescopes of these electric devices contain valuable components including the screen and conical glass and cathode-luminophors. Existing trends in the world of CRT faceplates cullet recycling argue for reasonability of recycling ways of this valuable secondary raw materials. Aim: The aim of researches is to determine the impact of the full replacement of quartz sand by faceplates cullet and using the zinc sulfide, reconstituted of used cathode-luminophors, as a secondary raw material in the production of glass-like glaze on the basic properties of color glaze. Materials and Methods: Cathode-ray tube faceplates are cut off during removal process, washed from dirt, dried, crushed by press, milled in a cheek grinder and finally crushed in a barrel mill. The slurried impurity (clay, dyes of desired color, including ZnS, water are added to this powder. The received mix is processed of wet grinding for slip production. Slip is surfaced on glass-ceramic tile, dried up, burned at maximum temperature of 900ºС. Results: Experimental research has shown that glass-forming, modifying and intermediate oxides of inorganic substances are added to the glaze with the CRT faceplates cullet. The Chasiv Yar clay belongs to the group with significant gas emission. The water vapor arising during the clay dehydration plays role of the "carrier" of heavy non-volatile components, considerably accelerates gas processes and increases activity of gas components. Zinc sulphide, dissolved in the silicate glaze melts when heated

  19. Cask systems development program seal technology

    International Nuclear Information System (INIS)

    Madsen, M.M.; Humphreys, D.L.; Edwards, K.R.

    1991-01-01

    General design or test performance requirements for radioactive materials (RAM) packages are specified in Title 10 of the US Code of Federal Regulations Part 71 (10 CFR 71). Seals that provide the containment system interface between the packaging body and the closure must function in both high- and low-temperature environments under dynamic and static conditions. Experiments were performed to characterize the performance of several seal materials at low temperatures. Helium leak tests on face seals were used to compare the materials. Materials tested include butyl, neoprene, ethylene propylene, fluorosilicone, silicone, Eypel, Kalrez, Teflon, fluorocarbon, and Teflon/silicone composites. Results show that the seal materials tested, with the exception of silicone S613-60, are not leak tight (1 x 10 -7 std cm 3 /s) at manufacturer low-temperature ratings

  20. Properties of Sealing Materials in Groundwater Wells

    DEFF Research Database (Denmark)

    Köser, Claus

    pellets as sealing material in groundwater wells. The way and the pattern, in which bentonite pellets are deposited, have been shown to have an effect on the swelling pressure of the bentonite seal. During the transport phase of pellets from the terrain to a given sedimentation depth, a sorting process......) into densities for clay/water systems has been developed. This method has successfully been used to evaluate e.g., macroporosity, homogenization of the bentonite seal during the hydration of water, hydraulic conductivity and the creation of channels in the bentonite seals. Based on the results obtained...

  1. Intestinal absorption and excretion of zinc in streptozotocin-diabetic rats as affected by dietary zinc and protein

    International Nuclear Information System (INIS)

    Johnson, W.T.; Canfield, W.K.

    1985-01-01

    65 Zn was used to examine the effects of dietary zinc and protein on true zinc absorption and intestinal excretion of endogenous zinc by an isotope dilution technique in streptozotocin-diabetic and control rats. Four groups each of diabetic and control rats were fed diets containing 20 ppm Zn, 20% egg white protein (HMHP); 20 ppm Zn, 10% egg white protein (HMLP); 10 ppm Zn, 20% egg white protein (LMHP); and 10 ppm Zn, 10% egg white protein (LMLP). Measurement of zinc balance was begun 9 d after an i.m. injection of 65 Zn. True zinc absorption and the contribution of endogenous zinc to fecal zinc excretion were calculated from the isotopically labeled and unlabeled zinc in the feces, duodenum and kidney. Results from the isotope dilution study indicated that diabetic rats, but not control rats, absorbed more zinc from 20 ppm zinc diets than from 10ppm zinc diets and that all rats absorbed more zinc from 20% protein diets than from 10% protein diets. Furthermore, all rats excreted more endogenous zinc from their intestines when dietary zinc and protein levels resulted in greater zinc absorption. In diabetic and control rats, consuming equivalent amounts of zinc, the amount of zinc absorbed was not significantly different, but the amount of zinc excreted by the intestine was less in the diabetic rats. Decreased intestinal excretion of endogenous zinc may be a homeostatic response to the increased urinary excretion of endogenous zinc in the diabetic rats and may also lead to the elevated zinc concentrations observed in some organs of the diabetic rats

  2. Replacement of nickel sealing rings by expanded graphite sealing rings -upgrading of SG primary collector flange connection

    Energy Technology Data Exchange (ETDEWEB)

    Cikryt, F.; Bednarek, L.; Kusyn, L. [Vitkovice, Ostrava (Switzerland)

    1997-12-31

    One of the most loaded parts of a steam generator of VVER 440 MW type are the bolts and thread holes of the primary collector cover sealing set. The strength calculations and tensometric measurings performed during operation proved the high degree of a load on the bolts. The conditions of the stress limitation are not met in some cases according to the pertinent standards. The untightnesses at nickel rings occurred during putting the units of Jaslovske Bohunice and Dukovany nuclear power stations into operation. With regard to improve the reliability, the producer has taken measures to improve the quality of the rings and users have introduced more strict regulations for bolts tightening. Due to these measures the high reliability of the set has been obtained from point of view of the tightness, but substantial reduction of bolts and holes threads loading have not been obtained. Several years operation experience proved relatively low service of bolts, damage of thread holes and sealing grooves. As the degree of mechanical load is one of the vital parameters influencing the damage of sealing set, in 1996 we started with the works aimed at a possibility of nickel sealing rings replacement for a more modern type of sealing which assure the higher reliability and service life of the individual part of sealing set under the reduced load.

  3. Replacement of nickel sealing rings by expanded graphite sealing rings -upgrading of SG primary collector flange connection

    Energy Technology Data Exchange (ETDEWEB)

    Cikryt, F; Bednarek, L; Kusyn, L [Vitkovice, Ostrava (Switzerland)

    1998-12-31

    One of the most loaded parts of a steam generator of VVER 440 MW type are the bolts and thread holes of the primary collector cover sealing set. The strength calculations and tensometric measurings performed during operation proved the high degree of a load on the bolts. The conditions of the stress limitation are not met in some cases according to the pertinent standards. The untightnesses at nickel rings occurred during putting the units of Jaslovske Bohunice and Dukovany nuclear power stations into operation. With regard to improve the reliability, the producer has taken measures to improve the quality of the rings and users have introduced more strict regulations for bolts tightening. Due to these measures the high reliability of the set has been obtained from point of view of the tightness, but substantial reduction of bolts and holes threads loading have not been obtained. Several years operation experience proved relatively low service of bolts, damage of thread holes and sealing grooves. As the degree of mechanical load is one of the vital parameters influencing the damage of sealing set, in 1996 we started with the works aimed at a possibility of nickel sealing rings replacement for a more modern type of sealing which assure the higher reliability and service life of the individual part of sealing set under the reduced load.

  4. Application of radioisotope technique for investigation of pumps seals

    International Nuclear Information System (INIS)

    Antoszewski, B.; Zorawska, A.

    1988-01-01

    Radioisotope method of measuring the wear of rings of the face mechanical seals, bush in soft seals, and leakage in double mechanical seals is described. The examples are given. It is found that radioisotope technique can be used for investigation of the seals. (author)

  5. Experimental facility design for study of fretting in steam generator tubes

    International Nuclear Information System (INIS)

    Balbiani, J.P.; Bergant, M.; Yawny, A.

    2012-01-01

    The design of an experimental facility for fretting wear testing of steam generator tubes under pressurized water up to 340 o C, is presented. The main component of the device consists in an autoclave which permits to recreate steam generator operating conditions. CAD CATIA V5R18, CAE ABAQUS and ASME Sec. VII Div. 1 (Rules for Construction of Pressure Vessels) were used along the design process. The design of the autoclave included the pressure vessel itself and the necessary flanges and nozzles. In addition, an axial dynamic sealing system was designed to allow for actuation from outside the pressure boundary. Complementary, typical tube - support contact conditions were analyzed and the principal variables affecting their mutual interaction determined. In addition, a simple device which allows performing fretting wear testing on steam generator tubes in air at room temperature was fabricated and the feasibility of a quantitative assessment of different aspects related with the fretting induced damage was explored. Characterization techniques available at Centro Atomico Bariloche, like light microscopy, scanning electron microscopy (SEM), energy dispersive analysis of X-ray (EDAX) and surface damage analysis by optic profilometry were shown to be appropriate for this aim. The designed facility will allow evaluating fretting damage of tubes - support combinations that might be used on the steam generator of the prototype reactor CAREM-25. It is also expected it could be applied to characterize fretting severity in other applications (nuclear fuel elements) (author)

  6. Legacy HMSRP Hawaiian Monk Seals Observers

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — This data set documents observers that have collected monk seal data as part of the ongoing monk seal population assessment efforts by PSD personnel and cooperating...

  7. HMSRP Hawaiian Monk Seal Entanglement data

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — The data set contains records of all entanglements of Hawaiian monk seals in marine debris. The data set comprises records of seals entangled by derelict fishing...

  8. Salt brickwork as long-term sealing in salt formations

    International Nuclear Information System (INIS)

    Walter, F.; Yaramanci, U.

    1993-01-01

    Radioactive wastes can be disposed of in deep salt formations. Rock salt is a suitable geologic medium because of its unique characteristics. Open boreholes, shafts and drifts are created to provide physical access to the repository. Long-term seals must be emplaced in these potential pathways to prevent radioactive release into the biosphere. The sealing materials must be mechanically and, most important, geochemically stable within the host rock. Salt bricks made from compressed salt-powder are understood to be the first choice long-term sealing material. Seals built of salt bricks will be ductile. Large sealing systems are built by combining the individual bricks with mortar. Raw materials for mortar are fine-grained halite powder and ground saliferous clay. This provides for the good adhesive strength of the mortar to the bricks and the high shear-strength of the mortar itself. To test the interaction of rock salt with an emplaced long-term seal, experiments will be carried out in situ, in the Asse salt mine in Germany. Simple borehole sealing experiments will be performed in horizontal holes and a complicated drift sealing experiment is planned, to demonstrate the technology of sealing a standard size drift or shaft inside a disturbed rock mass. Especially, the mechanical stability of the sealing system has to be demonstrated

  9. Sealed source peer review plan

    International Nuclear Information System (INIS)

    Feldman, Alexander; Leonard, Lee; Burns, Ron

    2009-01-01

    Sealed sources are known quantities of radioactive materials that have been encapsulated in quantities that produce known radiation fields. Sealed sources have multiple uses ranging from instrument calibration sources to sources that produce radiation fields for experimental applications. The Off-Site Source Recovery (OSR) Project at Los Alamos National Laboratory (LANL), created in 1999, under the direction of the Waste Management Division of the U.S. Department of Energy (DOE) Albuquerque has been assigned the responsibility to recover and manage excess and unwanted radioactive sealed sources from the public and private sector. LANL intends to ship drums containing qualified sealed sources to the Waste Isolation Pilot Plant (WIPP) for disposal. Prior to shipping, these drums must be characterized with respect to radiological content and other parameters. The U. S. Environmental Protection Agency (EPA) requires that ten radionulcides be quantified and reported for every container of waste to be disposed in the WIPP. The methods traditionally approved by the EPA include non-destructive assay (NDA) in accordance with Appendix A of the Contact-Handled Transuranic Waste Acceptance Criteria for the Waste Isolation Pilot Plant (DOE, 2002) (CH WAC). However, because of the nature and pedigree of historical records for sealed sources and the technical infeasibility of performing NDA on these sources, LANL proposes to characterize the content of these waste drums using qualified existing radiological data in lieu of direct measurement. This plan describes the process and documentation requirements for the use of the peer review process to qualify existing data for sealed radiological sources in lieu of perfonning radioassay. The peer review process will be performed in accordance with criteria provided in 40 CFR (section) 194.22 which specifies the use of the NUREG 1297 guidelines. The plan defines the management approach, resources, schedule, and technical requirements

  10. Long term testing of materials for tube shielding, stage 2; Laangtidsprovning av tubskyddsmaterial, etapp 2

    Energy Technology Data Exchange (ETDEWEB)

    Norling, Rikard; Hjoernhede, Anders; Mattsson, Mattias

    2012-02-15

    Circulating Fluidized Bed (CFB) boilers are commonly used for combustion of biomass and are used to some extent for Waste-to-Energy (WtE) plants as well. The superheaters of the latter are for obvious reasons more prone to suffer from high temperature corrosion caused by the corrosive species in the fuel, mainly chlorides. Frequently the final (hottest) superheater is positioned in the loop seal, where the circulating bed material is returned to the furnace after being separated from the flue gas by a cyclone. The environment in the loop seal is relatively free of chlorides, since these primarily follow the flue gas into the convection pass. Hence, higher steam temperature can be allowed without excessive damage to the final superheater. On the other hand the superheaters, which are located in the convection pass, are more exposed to the corrosive species of the flue gas. Further, they are eroded by particles entrained in the gas flow. Particles and condensing gaseous species are to a large extent deposited on the superheaters, which limits the heat transfer and promotes corrosion. The deposits are regularly removed e.g. by soot blowers. The pressurized steam from soot blowers causes additional erosion damage to that caused by entrained particles. It shall be noted that the actual damage is caused by a combined mechanism of erosion and corrosion denoted erosion-corrosion, which usually results in dramatically accelerated wear. To avoid excessive erosion damage on the superheater tubes the first tube row of each bundle is protected by tube shielding. In its simplest form the shields are made from a steel sheet that has been bent into a semi-circular half-cylinder shell. These shields are attached onto the wind-side of the tubes by hangers. A typical material for tube shielding is the austenitic high temperature resistant stainless steel 253MA. Life of tube shielding depends on numerous factors such as boiler design, superheater location, fuel and operating

  11. Molybdenum sealing glass-ceramic composition

    International Nuclear Information System (INIS)

    Eagan, R.J.

    1976-01-01

    A glass-ceramic composition is described having low hydrogen and helium permeability properties, along with high fracture strength, and a thermal coefficient of expansion similar to that of molybdenum. The composition is adaptable for hermetically sealing to molybdenum at temperatures between 900 and about 950 0 C to form a hermetically sealed insulator body

  12. Zinc metabolism in genetically obese (ob/ob) mice

    International Nuclear Information System (INIS)

    Kennedy, M.L.; Failla, M.L.

    1987-01-01

    Recent reports indicate that the concentrations and total amounts of several essential trace metals in various tissues of genetically obese rodents differ markedly from those in lean controls. In the present studies the absorption, retention and tissue distribution of zinc and constitutive levels of zinc-metallothionein (Zn-MT) in selected tissues were compared in obese (ob/ob) and lean (+/?) C57BL/6J mice. When 5-, 10- and 22-wk-old mice were administered 1.2 mumol 65 Zn by stomach tube the apparent absorption of 65 Zn by obese mice was 1.5, 2.2 and 3.9 times higher, respectively, than that in age-matched lean mice. Retention of orally administered 65 Zn after 96 h was also substantially higher in obese mice than in lean mice. To assess the possible influences of hyperphagia and intestinal hypertrophy on the enhanced apparent absorption of 65 Zn by obese mice food intake by an additional group of obese mice was restricted to that of age-matched lean controls. When actual absorption of zinc was determined according to the method of Heth and Hoekstra, groups of ad libitum--fed obese, pair-fed obese and lean mice absorbed 38, 32 and 18% of administered 65 Zn, respectively. In contrast, the rate of 65 Zn excretion 2-6 d after oral or subcutaneous administration of the metal was similar for obese and lean mice. Unrestricted and pair-fed obese mice had significantly lower percentages of carcass 65 Zn present in skin, muscle plus bone, spleen and testes and higher percentages present in liver, small intestine and adipose tissue than lean mice

  13. Acoustic resonance spectroscopy intrinsic seals

    International Nuclear Information System (INIS)

    Olinger, C.T.; Burr, T.; Vnuk, D.R.

    1994-01-01

    We have begun to quantify the ability of acoustic resonance spectroscopy (ARS) to detect the removal and replacement of the lid of a simulated special nuclear materials drum. Conceptually, the acoustic spectrum of a container establishcs a baseline fingerprint, which we refer to as an intrinsic seal, for the container. Simply removing and replacing the lid changes some of the resonant frequencies because it is impossible to exactly duplicate all of the stress patterns between the lid and container. Preliminary qualitative results suggested that the ARS intrinsic seal could discriminate between cases where a lid has or has not been removed. The present work is directed at quantifying the utility of the ARS intrinsic seal technique, including the technique's sensitivity to ''nuisance'' effects, such as temperature swings, movement of the container, and placement of the transducers. These early quantitative tests support the potential of the ARS intrinsic seal application, but also reveal a possible sensitivity to nuisance effects that could limit environments or conditions under which the technique is effective

  14. Plastic profiled sealing element for household refrigeration appliances

    Energy Technology Data Exchange (ETDEWEB)

    Wunderlich, E; Robl, G

    1988-12-28

    A plastic profiled sealing element for household refrigeration appliances, such as freezers, refrigerators, and freezer compartments, includes a sealing bellows having a hose-shaped cross section. The sealing bellows is provided with two side walls and a covering wall, and is made of a plastic that has been set by means of a softener so as to be continuously flexible. Further, the profiled sealing element is provided with an anchor member made of a plastic of the same or different material hardness, with the sealing bellows and the anchor member being connected with one another to form a unit. The cross sections of the two side walls of the sealing bellows narrow as the side walls rise from the region of the connection of the side walls with the covering wall of the anchor member to approximately half the height of the sealing bellows, so that the side walls become increasingly thinner. Thereafter, the cross sections of the side walls increase again to the edges of the covering wall of the sealing bellows, until the side walls again reach approximately their initial cross sections. The side walls, on the one hand, and the covering wall, on the other hand, are kept flexible by means of softeners having different characteristics.

  15. Chelators for investigating zinc metalloneurochemistry

    OpenAIRE

    Radford, Robert John; Lippard, Stephen J.

    2013-01-01

    The physiology and pathology of mobile zinc signaling has become an important topic in metalloneurochemistry. To study the action of mobile zinc effectively, specialized tools are required that probe the temporal and positional changes of zinc ions within live tissue and cells. In the present article we describe the design and implementation of selective zinc chelators as antagonists to interrogate the function of mobile zinc, with an emphasis on the pools of vesicular zinc in the terminals o...

  16. Dynamics of face seals for high speed turbomachinery

    Science.gov (United States)

    Leefe, Simon

    1993-10-01

    Face seals in rocket engine fuel and oxidizer turbopumps have been the subject of intense investigation for over 25 years. While advances have been made in the understanding of thin film lubrication between seal faces, valuable data has been produced on the friction and wear of material pairs in cryogenic environments; pioneering work has been done on the effect of lubricant phase change in seals, and many improvements have been made in mechanical seal design. Relatively superficial attention has been given to the vibrational dynamics of face seals in high-speed turbomachinery. BHR Group Ltd. (formerly BHRA) has recently completed the first stage of a study, commissioned by the European Space Agency, to investigate this area. This has involved the development of a two-dimensional adiabatic, turbulent lubrication model for thick gas film applications, the production of an integrated mathematical model of gas seal vibrational dynamics for thin film applications, implementation in software, the undertaking of an experimental program to validate software against variations in operating conditions and design variables, and suggestions for improved seal design.

  17. HMSRP Hawaiian Monk Seal Handling Data

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — This data set contains records for all handling and measurement of Hawaiian monk seals since 1981. Live seals are handled and measured during a variety of events...

  18. Experimental study of single taylor bubbles rising in stagnant liquid mixtures inside of vertical tubes

    International Nuclear Information System (INIS)

    Azevedo, Marcos B. de; Faccini, Jose L.H.; Su, Jian

    2015-01-01

    The present work reports an experimental study of single Taylor bubbles rising in vertical tubes filled with water-glycerin mixtures by using the pulse-echo ultrasonic technique. A 2m long acrylic tube with inner diameter of 24 mm was used in the experiments. Initially, the tube was sealed at the ends and filled partially with the liquid mixtures to leave an air pocket of length L 0 at the top end. A Taylor bubble was formed by the inversion of the tube. The rising bubbles were detected by ultrasonic transducers located at the upper part of the tube. The velocity, the length and the pro le of the bubbles and the thickness of the liquid lm around them were obtained from the ultrasonic signals processing. The liquid lm thickness in the vertical tube was also determined by a graphic method that relates the bubble length L b with the initial length of the air pocket L 0 . It was observed that the bubble velocity decreased with increasing viscosity, while the lm thickness increased. It was shown that the liquid lm thickness determined by the graphic method fitted well the higher viscosities data, but overestimated the lower viscosities data. Additionally, the results indicated that some correlations developed to estimate the thickness of liquid films falling down inside/outside of tubes and down a plane surface could be applied to estimate the thickness of liquid films falling around Taylor bubbles in an Inverse Viscosity Number (N f ) range different to those considered in the literature. (author)

  19. 39 CFR 2.4 - Seal.

    Science.gov (United States)

    2010-07-01

    ... 39 Postal Service 1 2010-07-01 2010-07-01 false Seal. 2.4 Section 2.4 Postal Service UNITED STATES... Secretary of State, and is required by 39 U.S.C. 207 to be judicially noticed. The Seal shall be in the... description of the Postal Service emblem is described at 39 CFR 221.7. ...

  20. Zinc and gastrointestinal disease

    Institute of Scientific and Technical Information of China (English)

    Sonja; Skrovanek; Katherine; DiGuilio; Robert; Bailey; William; Huntington; Ryan; Urbas; Barani; Mayilvaganan; Giancarlo; Mercogliano; James; M; Mullin

    2014-01-01

    This review is a current summary of the role that both zinc deficiency and zinc supplementation can play in the etiology and therapy of a wide range of gastrointestinal diseases. The recent literature describing zinc action on gastrointestinal epithelial tight junctions and epithelial barrier function is described. Zinc enhancement of gastrointestinal epithelial barrier function may figure prominently in its potential therapeutic action in several gastrointestinal diseases.