WorldWideScience

Sample records for sealed source radiation

  1. Wipe testing of sealed radiation sources using a radiation protection assistant robot

    Directory of Open Access Journals (Sweden)

    Zeb Jahan

    2009-01-01

    Full Text Available Sealed radiation sources are commonly used in different research institutes, industries, and hospitals. The sources of various strengths are manufactured in different sizes and shapes. It is a regulatory requirement that these sources must be monitored frequently for their integrity and to avoid any radiological contamination hazard. Mainly, a wipe test is recommended for the contamination detection due to the leakage of sealed radiation sources. A radiation protection assistant robot has been fabricated to execute different tasks in a hazardous radiation environment. In this study, the robot was used to conduct the wipe test of five sealed radiation sources. The sealed radiation sources were tested safely and securely without giving any radiation dose to the radiation worker. The radiation doses received by the robot gripper and waist during the wipe test were 3.4 Gy and 208.9 mGy, respectively.

  2. Wipe testing of sealed radiation sources using a radiation protection assistant robot

    OpenAIRE

    Zeb Jahan; Rashid Farooq; Iqbal Naeem; Ahmad Nasir

    2009-01-01

    Sealed radiation sources are commonly used in different research institutes, industries, and hospitals. The sources of various strengths are manufactured in different sizes and shapes. It is a regulatory requirement that these sources must be monitored frequently for their integrity and to avoid any radiological contamination hazard. Mainly, a wipe test is recommended for the contamination detection due to the leakage of sealed radiation sources. A radiation protection assistant robot has bee...

  3. Development of quality assurance procedures for production of sealed radiation source

    CERN Document Server

    Nam, J H; Cho, W K; Han, H S; Hong, S B; Kim, K H; Kim, S D; Lee, Y G; Lim, N J

    2001-01-01

    The quality assurance procedures for sealed radiation sources production using HANARO and RIPF have been developed. The detailed quality assurance procedures are essential to manage the whole work process effectively and ensure the quality of the produced sealed sources. Through applying this quality assurance procedures to the entire production works of the sealed radiation sources, it is expected that the quality of the products, the safety of the works and the satisfaction of the customers will be increased.

  4. Sealed source peer review plan

    Energy Technology Data Exchange (ETDEWEB)

    Feldman, Alexander [Los Alamos National Laboratory; Leonard, Lee [RETIRED; Burns, Ron [CONTRACTOR

    2009-01-01

    Sealed sources are known quantities of radioactive materials that have been encapsulated in quantities that produce known radiation fields. Sealed sources have multiple uses ranging from instrument calibration sources to sources that produce radiation fields for experimental applications. The Off-Site Source Recovery (OSR) Project at Los Alamos National Laboratory (LANL), created in 1999, under the direction of the Waste Management Division of the U.S. Department of Energy (DOE) Albuquerque has been assigned the responsibility to recover and manage excess and unwanted radioactive sealed sources from the public and private sector. LANL intends to ship drums containing qualified sealed sources to the Waste Isolation Pilot Plant (WIPP) for disposal. Prior to shipping, these drums must be characterized with respect to radiological content and other parameters. The U. S. Environmental Protection Agency (EPA) requires that ten radionulcides be quantified and reported for every container of waste to be disposed in the WIPP. The methods traditionally approved by the EPA include non-destructive assay (NDA) in accordance with Appendix A of the Contact-Handled Transuranic Waste Acceptance Criteria for the Waste Isolation Pilot Plant (DOE, 2002) (CH WAC). However, because of the nature and pedigree of historical records for sealed sources and the technical infeasibility of performing NDA on these sources, LANL proposes to characterize the content of these waste drums using qualified existing radiological data in lieu of direct measurement. This plan describes the process and documentation requirements for the use of the peer review process to qualify existing data for sealed radiological sources in lieu of perfonning radioassay. The peer review process will be performed in accordance with criteria provided in 40 CFR {section} 194.22 which specifies the use of the NUREG 1297 guidelines. The plan defines the management approach, resources, schedule, and technical requirements

  5. Recommendations for the safe use of external beams and sealed brachytherapy sources in radiation oncology

    Energy Technology Data Exchange (ETDEWEB)

    Millar, M. [William Buckland Radiotherapy Centre, Melbourne, VIC, (Australia); Cramb, J.; Das, R.; Ackerly, T. [Peter McCallum Cancer Institute, Melbourne, VIC, (Australia); Brown, G. [East Melbourne Radiation Oncology Centre, Melbourne, VIC, (Australia); Webb, D. [Australian Radiation Laboratory, Melbourne, VIC, (Australia)

    1997-09-01

    The Australasian College of Physical Scientists and Engineers in Medicine (ACPSEM) has made a number of attempts to produce a document covering practices and quality assurance in radiation oncology. This document originated from `Code of Safe Practice for the Use of Irradiating Apparatus in Medical Therapy`, prepared by V. Smyth for the official National Radiation Laboratory (of New Zealand) document NRL C12. In Sept. 1993, the ACPSEM quality assurance topic group formed a sub-committee to produce a document for adoption by the ACPSEM. This document is intended to cover safe practices in the fields of radiation oncology or radiotherapy (for humans) and the radiation therapy aspects of dermatology and ophtalmology. It is not intended to cover the use of unsealed sources used in nuclear medicine. This final version contains some corrections and clarifications requested by the college council. The Sub-committee responsible for drawing up this document envisages that it will be reviewed by the ACPSEM in three years to see what changes, if any need to be made in order to make the document more useful and to ensure that it reflects current practices. 42 refs., appendices.

  6. Conditioning of Spent Sealed Sources in Singapore

    Energy Technology Data Exchange (ETDEWEB)

    Hong, Dae Seok; Kang, Il Sik; Jang, Kyung Duk; Shon, Jong Sik [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of)

    2012-05-15

    In 2010, IAEA (International Atomic Energy Agency) requested KAERI (Korea Atomic Energy Research Institute) to support Singapore for conditioning spent sealed sources. Once had been used for lightning conductor, check source or smoke detector, various sealed sources were collected and temporarily have been stored at HSA (Health Science Authority) under control of NEA (National Environment Agency) in Singapore. Based on experiences for conditioning of Ra-226 sources in various Asian countries since 2000, KAERI sent an expert team of three members to Singapore for safe management of spent sealed sources in 2011. As a result of conditioning operation, about 575.21 mCi of sealed sources were safely conditioned in 3 cement packages with cooperation of KAERI expert team, IAEA supervisor, NEA staffs and local labors. In this paper, procedure and result of the conditioning operation for the spent sealed sources in Singapore are discussed

  7. Integrated Management Program Radioactive Sealed Sources in Egypt

    Energy Technology Data Exchange (ETDEWEB)

    Hasan, A.; Cochran, J. R.; El-Adham, K.; El-Sorougy, R.

    2003-02-26

    The radioactive materials in ''public'' locations are typically contained in small, stainless steel capsules known as sealed radiation sources (RS). These capsules seal in the radioactive materials, but not the radiation, because it is the radiation that is needed for a wide variety of applications at hospitals, medical clinics, manufacturing plants, universities, construction sites, and other facilities in the public sector. Radiation sources are readily available, and worldwide there are hundreds of thousands of RS. The IMPRSS Project is a cooperative development between the Egyptian Atomic Energy Authority (EAEA), Egyptian Ministry of Health (MOH), Sandia National Laboratories (SNL), New Mexico Tech University (NMT), and Agriculture Cooperative Development International (ACDI/VOCA). SNL will coordinate the work scope between the participant organizations.

  8. Sealed source dismantling hot cell - startup

    Energy Technology Data Exchange (ETDEWEB)

    Dellamano, Jose Claudio; Ferreira, Robson de Jesus, E-mail: jcdellam@ipen.br, E-mail: rojefer@ipen.br [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), Sao Paulo, SP (Brazil). Gerencia de Rejeitos radioativos

    2013-07-01

    Sealed radioactive sources are widely used in many applications of nuclear technology and at the end of the useful life, most sources become radioactive waste. In Brazil, this waste is received by the Institutes of the National Nuclear Energy Commission and kept under centralized storage. The Waste Management Department at the Nuclear and Energy Research Institute is the main storage center, having received around 20,000 disused sources. A hot cell was designed and constructed to manage Co-60 spent sealed sources with activity up to 3.7 10{sup 1}0 Bq and other sources with equivalent activities. In the hot cell the sources are withdraw from their original shielding and transferred to a standard shielding for further disposal off. The original shielding disassembling is made outside the hot cell and after opening, it is transferred inside the hot cell and the sealed source is removed remotely. The source is checked in relation to external contamination and its activity is checked. After this, the source is positioned in the standard shielding located inside an overpack at the bottom of the hot cell. This paper describes some pre-operational tests carried out in it, that include: opening and closing doors and locks, checking of all electrical and pneumatic controls, the original shielding movement inside the hot-cell, dose rate measurements outside the hot-cell, insertion of the sealed sources inside the activity meter chamber, transferring the sealed source to the standard shielding, movement of the overpack with the standard shielding to outside of the hot-cell and plugging of the standard shielding. (author)

  9. An ideal sealed source life-cycle

    Energy Technology Data Exchange (ETDEWEB)

    Tompkins, Joseph Andrew [Los Alamos National Laboratory

    2009-01-01

    In the last 40 years, barriers to compliant and timely disposition of radioactive sealed sources have become apparent. The story starts with the explosive growth of nuclear gauging technologies in the 1960s. Dozens of companies in the US manufactured sources and many more created nuclear solutions to industrial gauging problems. Today they do not yet know how many Cat 1, 2, or 3 sources there are in the US. There are, at minimum, tens of thousands of sources, perhaps hundreds of thousands of sources. Affordable transportation solutions to consolidate all of these sources and disposition pathways for these sources do not exist. The root problem seems to be a lack of necessary regulatory framework that has allowed all of these problems to accumulate with no national plan for solving the problem. In the 1960s, Pu-238 displaced Pu-239 for most neutron and alpha source applications. In the 1970s, the availability of inexpensive Am-241 resulted in a proliferation of low energy gamma sources used in nuclear gauging, well logging, pacemakers, and X-ray fluorescence applications for example. In the 1980s, rapid expansion of worldwide petroleum exploration resulted in the expansion of Am-241 sources into international locations. Improvements of technology and regulation resulted in a change in isotopic distribution as Am-241 made Pu-239 and Pu-238 obsolete. Many early nuclear gauge technologies have been made obsolete as they were replaced by non-nuclear technoogies. With uncertainties in source end of life disposition and increased requirements for sealed source security, nuclear gauging technology is the last choice for modern process engineering gauging solutions. Over the same period, much was learned about licensing LLW disposition facilities as evident by the closure of early disposition facilities like Maxey Flats. The current difficulties in sealed source disposition start with adoption of the NLLW policy act of 1985, which created the state LLW compact system they

  10. RADIATION SOURCE

    Science.gov (United States)

    Gow, J.D.

    1961-06-27

    An improved version of a crossed electric and magnetic field plasma producing and containing device of the general character disclosed in U. S. Patent No. 2,967,943 is described. This device employs an annular magnet encased within an anode and a pair of cathodes respectively coaxially spaced from the opposite ends of the anode to establish crossed field electron trapping regions adjacent the ends of the anode. The trapping regions are communicably connected through the throat of the anode and the electric field negatively increases in opposite axial directions from the center of the throat. Electrons are trapped within the two trapping regions and throat to serve as a source of intense ionization to gas introduced thereto, the ions in copious quantities being attracted to the cathodes to bombard neutron productive targets dlsposed - thereat.

  11. Use of VUV Radiation to Control Elastomer Seal Adhesion

    Science.gov (United States)

    deGroh, Henry C., III; Puleo, Bernadette J.; Waters, Deborah L.

    2013-01-01

    Due to their wide operating temperatures and low leakage rates, silicone elastomers are the only class of flight qualified elastomer materials that currently meet NASA's needs for various seal applications, which include docking and hatch seals for future space exploration vehicles. However, silicone elastomers are naturally sticky and exhibit sizeable adhesion when mated against metals and other silicone surfaces. This undesirable adhesion can make undocking spacecraft or opening a hatch problematic. Two approaches that can be used to reduce seal adhesion include use of grease or, application of low doses of atomic oxygen (AO). This paper investigates a third approach: the application of light doses of vacuum ultraviolet (VUV) radiation. Presented are the adhesion and leakage characteristics of S0383-70 silicone elastomer exposed to various VUV doses in the 115 to 200 nm wavelength range. The data indicate that adhesion is expected to be less than the target threshold maximum of 2 lb/in(exp2) after about 1 J/cm(exp2) of VUV exposure for seal-to-metal configurations and after 2 J/cm(exp2) for seal-to-seal configurations with no significant damage, or increase in seal leakage. This paper shows that VUV, without AO or grease, can be an effective means to reduce adhesion to the desired levels necessary for space seals with minimal change in seal leak rates.

  12. A wavelength tunable photon source with sealed inner volume

    DEFF Research Database (Denmark)

    2014-01-01

    (214) being a sealed volume, and forming a bonding interface (212) which is gas-tight, so that the first mirror (106) is placed in the inner volume (214) so the first mirror (106) may move within the inner volume (214). The method provides a relatively simple way of obtaining a tunable photon source...... where the inner volume is sealed. The invention furthermore relates to a corresponding photon source, and use of such photon source....

  13. New sources of radiation

    Energy Technology Data Exchange (ETDEWEB)

    Schimmerling, W.

    1979-09-01

    An attempt is made to select examples of radiation sources whose application may make new or unconventional demands on radiation protection and dosimetry. A substantial body of knowledge about high energy facilities exists and, partly for this reason, the great high energy accelerators are mentioned only briefly.

  14. Study of acid solution bonding in epoxy matrix for sealed radioactive sources production

    Energy Technology Data Exchange (ETDEWEB)

    Benega, Marcos A.G.; Nagatomi, Helio R.; Rostelato, Maria Elisa C.M.; Tiezzi, Rodrigo; Rodrigues, Bruna T.; Peleias Junior, Fernando; Souza, Carla D.; Souza, Daiane C.C. de; Souza, Anderson S. de; Silva, Thais H. da, E-mail: carladdsouza@yahoo.com.br, E-mail: marcosagbenega@gmail.com, E-mail: hrnagato@ipen.br, E-mail: elisaros@ipen.br, E-mail: rktiezzi@gmail.com, E-mail: bteigarodrigues@gmail.com, E-mail: fernandopeleias@gmail.com, E-mail: dcsouza@ipen.br [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), Sao Paulo, SP (Brazil)

    2014-07-01

    The present work aims to analyze different resin formulations. These formulations are used in the production of radioactive sealed sources that are used in many fields such as nuclear medicine; environmental analyzes, radiation detectors accuracy check, and so on. These sources can be produced with different radioisotopes and different activities, it all depending on the use they will have. Certain types of resins have the same density water. This property is appreciated when we consider that radiotracers used in nuclear medicine are applied in aqueous solutions. So the sources used for checking and calibrating equipment must have their radioisotopes sealed in a material having similar properties, thus the measures are reproducible and repetitive. The most important aspect that is brought to attention in this work is the miscibility those resins have with water. The radioisotopes for the production of the sources are supplied in an aqueous form. In case the resin and the radioisotope solution do not mix, the source will not be sturdy enough to seal the radioisotopes in its structure and the source will not be safe. There were prepared different formulations with different amounts of acid solution, and the cured formulations were analyzed by Wipe Test, DSC (Differential Splanatory Calorimetry) and also, the possible volatile aspect of the radionuclide used. All to evaluate the integrity of the sources. The obtained results were satisfactory and show that when the resin is well cured, the radioisotope remains sealed in the matrix, making it possible to produce radioactive sealed sources. (author)

  15. 10 CFR 35.590 - Training for use of sealed sources for diagnosis.

    Science.gov (United States)

    2010-01-01

    ... Section 35.590 Energy NUCLEAR REGULATORY COMMISSION MEDICAL USE OF BYPRODUCT MATERIAL Sealed Sources for... on the NRC's Web page.); or (b) Has completed 8 hours of classroom and laboratory training in basic... the use and measurement of radioactivity; and (4) Radiation biology; and (c) Has completed training in...

  16. Synchrotron radiation sources

    Energy Technology Data Exchange (ETDEWEB)

    van Steenbergen, A.

    1979-01-01

    As a result of the exponential growth of the utilization of synchrotron radiation for research in the domain of the material sciences, atomic and molecular physics, biology and technology, a major construction activity has been generated towards new dedicated electron storage rings, designed optimally for synchrotron radiation applications, also, expansion programs are underway at the existing facilities, such as DORIS, SPEAR, and VEPP. In this report the basic properties of synchrotron radiation will be discussed, a short overview will be given of the existing and new facilities, some aspects of the optimization of a structure for a synchrotron radiation source will be discussed and the addition of wigglers and undulators for spectrum enhancement will be described. Finally, some parameters of an optimized synchrotron radiation source will be given.

  17. Radiation Source Replacement Workshop

    Energy Technology Data Exchange (ETDEWEB)

    Griffin, Jeffrey W.; Moran, Traci L.; Bond, Leonard J.

    2010-12-01

    This report summarizes a Radiation Source Replacement Workshop in Houston Texas on October 27-28, 2010, which provided a forum for industry and researchers to exchange information and to discuss the issues relating to replacement of AmBe, and potentially other isotope sources used in well logging.

  18. Elastomeric Seal Performance after Terrestrial Ultraviolet Radiation Exposure

    Science.gov (United States)

    Daniels, Christopher C.; Oravec, Heather A.; Mather, Janice L.; Taylor, Shawn C.; Dunlap, Patrick H.

    2015-01-01

    Ultraviolet radiation was evaluated to determine its negative effects on the performance of elastomeric gas pressure seals. The leak rates of the silicone elastomer S0383-70 O-ring test articles were used to quantify the degradation of the seals after exposure to vacuum-ultraviolet and/or middle-to-near-ultraviolet wavelength radiation. Three groups of seals were exposed in terrestrial facilities to 115-165 nm wavelength radiation, 230-500 nm wavelength radiation, or both spectrums, for an orbital spaceflight equivalent of 125 hours. The leak rates of the silicone elastomer S0383-70 seals were quantified and compared to samples that received no radiation. Each lot contained six samples and statistical t-tests were used to determine the separate and combined influences of exposure to the two wavelength ranges. A comparison of the mean leak rates of samples exposed to 115-165 nm wavelength radiation to the control specimens showed no difference, suggesting that spectrum was not damaging. The 230-500 nm wavelength appeared to be damaging, as the mean leak rates of the specimens exposed to that range of wavelengths, and those exposed to the combined 115-165 nm and 230-500 nm spectrums, were significantly different from the leak rates of the control specimens. Most importantly, the test articles exposed to both wavelength spectrums exhibited mean leak rates two orders of magnitude larger than any other exposed specimens, which suggested that both wavelength spectrums are important when simulating the orbital environment.

  19. 10 CFR 35.67 - Requirements for possession of sealed sources and brachytherapy sources.

    Science.gov (United States)

    2010-01-01

    ... brachytherapy sources. 35.67 Section 35.67 Energy NUCLEAR REGULATORY COMMISSION MEDICAL USE OF BYPRODUCT... brachytherapy sources. (a) A licensee in possession of any sealed source or brachytherapy source shall follow... brachytherapy sources, except for gamma stereotactic radiosurgery sources, shall conduct a semi-annual physical...

  20. Future Synchrotron Radiation Sources

    CERN Document Server

    Winick, Herman

    2003-01-01

    Sources of synchrotron radiation (also called synchrotron light) and their associated research facilities have experienced a spectacular growth in number, performance, and breadth of application in the past two to three decades. In 1978 there were eleven electron storage rings used as light sources. Three of these were small rings, all below 500 mega-electron volts (MeV), dedicated to this purpose; the others, with energy up to 5 giga-electron volts (GeV), were used parasitically during the operation of the ring for high energy physics research. In addition, at that time synchrotron radiation from nine cyclic electron synchrotrons, with energy up to 5 GeV, was also used parasitically. At present no cyclic synchrotrons are used, while about 50 electron storage rings are in operation around the world as fully dedicated light sources for basic and applied research in a wide variety of fields. Among these fields are structural molecular biology, molecular environmental science, materials, analytic chemistry, micr...

  1. Procedure to carry out leakage test in beta radiation sealed sources emitters of {sup 90}Sr/{sup 90}Y; Procedimiento para realizar prueba de fuga en fuentes selladas de radiacion beta emisoras de {sup 90}Sr/{sup 90}Y

    Energy Technology Data Exchange (ETDEWEB)

    Alvarez R, J. T., E-mail: trinidad.alvarez@inin.gob.m [ININ, Departamento de Metrologia de Radiaciones Ionizantes, Laboratorio Secundario de Calibracion Dosimetrica, Carretera Mexico-Toluca s/n, 52750 Ocoyoacac, Estado de Mexico (Mexico)

    2010-09-15

    In the alpha-beta room of the Secondary Laboratory of Dosimetric Calibration of the Metrology Department of Ionizing Radiations ophthalmic applicators are calibrated in absorbed dose terms in water D{sub w}; these applicators, basically are emitter sealed sources of pure beta radiation of {sup 90}Sr / {sup 90}Y. Concretely, the laboratory quality system indicates to use the established procedure for the calibration of these sources, which establishes the requirement of to carry out a leakage test, before to calibrate the source. However, in the Laboratory leakage test certificates sent by specialized companies in radiological protection services have been received, in which are used gamma spectrometry equipment s for beta radiation leakage tests, since it is not reliable to detect pure beta radiation with a scintillating detector with NaI crystal, (because it could detect the braking radiation produced in the detector). Therefore the Laboratory has had to verify the results of the tests with a correct technique, with the purpose of determining the presence of sources with their altered integrity and radioactive material leakage. The objective of this work is to describe a technique for beta activity measurement - of the standard ISO 7503, part 1 (1988) - and its application with a detector Gm plane (type pankage) in the realization of leakage tests in emitter sources of pure beta radiation, inside the mark of quality assurance indicated by the report ICRU 76. (Author)

  2. Sure confinement of spent sealed sources; Confinamiento seguro de fuentes selladas gastadas

    Energy Technology Data Exchange (ETDEWEB)

    Lizcano, D., E-mail: david.lizcano@inin.gob.mx [ININ, Departamento de Desechos Radiactivos, Carretera Mexico-Toluca s/n, 52750 Ocoyoacac, Estado de Mexico (Mexico)

    2013-10-15

    The industrial and technological development of the last decades produced and increment in the radiations application in different human activities. One of the main effects has been the production of radioactive wastes of all the levels. In Mexico, several stages of the waste management of low and intermediate level have not been completely resolved, as the case of the treatment and the final storage. In this work the confinement of spent sealed sources is described, maintaining as main objective the security of these sources and the protection to the workers and the people. (author)

  3. 10 CFR 35.2067 - Records of leaks tests and inventory of sealed sources and brachytherapy sources.

    Science.gov (United States)

    2010-01-01

    ... brachytherapy sources. 35.2067 Section 35.2067 Energy NUCLEAR REGULATORY COMMISSION MEDICAL USE OF BYPRODUCT MATERIAL Records § 35.2067 Records of leaks tests and inventory of sealed sources and brachytherapy sources... of the semi-annual physical inventory of sealed sources and brachytherapy sources required by § 35.67...

  4. Strategic planning as a competitive differential: A case study of the Sealed Sources Production Laboratory

    Energy Technology Data Exchange (ETDEWEB)

    Vieira, Imário; Nascimento, Fernando C.; Calvo, Wilson A. Parejo, E-mail: imariovieira@yahoo.com, E-mail: wapcalvo@ipen.br, E-mail: fcodelo@gmail.com [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), Sao Paulo, SP (Brazil); Faculdade SENAI de Tecnologia Ambiental, Sao Bernardo do Campo, SP (Brazil)

    2017-11-01

    Strategic planning has always been and continues to be one of the most important management tools for decision making. Amidst the uncertainties of the 21{sup st} century, public, private and third sector organizations are steadily struggling to improve their strategic plans by using more effective results management tools such as BSC-Balanced Scorecard. Nuclear research institutes and research centers around the world have been using more and more these types of tools in their strategic planning and management. The objective of this article was to recommend the use the BSC as a strategic tool for decision making for the Sealed Sources Production Laboratory located in the Radiation Technology Center, at Nuclear and Energy Research Institute (IPEN/CNEN-SP), in Sao Paulo, Brazil. The methodology used in this academic article was a case study, which considered the object of the study, the Sealed Sources Production Laboratory, from January 2014 to August 2016. Among the main results obtained with this study can be cited: the improvement of the information flow, the visualization and proposition to change the periodicity of analysis of the results, among others. In view of the expected results, it was possible to conclude that this study may be of value to the Sealed Sources Production Laboratory for Industrial Radiography and Industrial Process Control and also to other research centers, as it will allow and contribute with an additional management support tool. (author)

  5. Compton Sources of Electromagnetic Radiation

    Energy Technology Data Exchange (ETDEWEB)

    Geoffrey Krafft,Gerd Priebe

    2011-01-01

    When a relativistic electron beam interacts with a high-field laser beam, intense and highly collimated electromagnetic radiation will be generated through Compton scattering. Through relativistic upshifting and the relativistic Doppler effect, highly energetic polarized photons are radiated along the electron beam motion when the electrons interact with the laser light. For example, X-ray radiation can be obtained when optical lasers are scattered from electrons of tens-of-MeV beam energy. Because of the desirable properties of the radiation produced, many groups around the world have been designing, building, and utilizing Compton sources for a wide variety of purposes. In this review article, we discuss the generation and properties of the scattered radiation, the types of Compton source devices that have been constructed to date, and the prospects of radiation sources of this general type. Due to the possibilities of producing hard electromagnetic radiation in a device that is small compared to the alternative storage ring sources, it is foreseen that large numbers of such sources may be constructed in the future.

  6. Intense XUV Radiation Sources.

    Science.gov (United States)

    1987-09-30

    eisl dilos energ-- NU perra dIIj i lj a tpIs- e firc linte, or otiher subs ~true! L reS is ouhd aIppear It dile con1- t ak inrg the spectra. 11nut~ %sere...dependence of the VUV output vs laser the imaged source relative to the spectrograph slit, the energy for the Ng:YAG laser. Analysis of the depen...Mcllrath and M.L. Ginter, "Rare-Earth Plasma Light Source for VUV Applications" Appl. Opt. 20, 3043 (1981). 7. Standard Methods of Water Analysis , 6th

  7. RADIOLOGICAL CRITERIA FOR PATIENT RELEASE FROM CLINIC AFTER RADIONUCLIDE THERAPY OF BRACHYTHERAPY WITH SEALED SOURCE IMPLANTATION

    Directory of Open Access Journals (Sweden)

    M. I. M.I. Balonov

    2009-01-01

    Full Text Available Dose criteria for limitation of exposure incurred by persons helping the patients or living with patients discharged from hospitals following radionuclide therapy or brachytherapy with implanted sealed radionuclide sources have been proposed for national Russian regulation. By means of a conservative dosimetry model, the values of operational radiological criteria for patient discharge from hospital are substantiated, i.e. whole body activity for radionuclides 125I,131I,153Sm and 188Re as well as dose rate near patient body. Observance of suggested criteria included in the new Russian Standards for Radiation Safety (RSS-99/2009 will ensure radiation safety of people in near environment (family, close friends et ah.

  8. Radiation sources working group summary

    Energy Technology Data Exchange (ETDEWEB)

    Fazio, M.V.

    1998-12-31

    The Radiation Sources Working Group addressed advanced concepts for the generation of RF energy to power advanced accelerators. The focus of the working group included advanced sources and technologies above 17 GHz. The topics discussed included RF sources above 17 GHz, pulse compression techniques to achieve extreme peak power levels, components technology, technology limitations and physical limits, and other advanced concepts. RF sources included gyroklystrons, magnicons, free-electron masers, two beam accelerators, and gyroharmonic and traveling wave devices. Technology components discussed included advanced cathodes and electron guns, high temperature superconductors for producing magnetic fields, RF breakdown physics and mitigation, and phenomena that impact source design such as fatigue in resonant structures due to RF heating. New approaches for RF source diagnostics located internal to the source were discussed for detecting plasma and beam phenomena existing in high energy density electrodynamic systems in order to help elucidate the reasons for performance limitations.

  9. Vacuum seals design and testing for a linear accelerator of the National Spallation Neutron Source

    Energy Technology Data Exchange (ETDEWEB)

    Z. Chen; C. Gautier; F. Hemez; N. K. Bultman

    2000-02-01

    Vacuum seals are very important to ensure that the Spallation Neutron Source (SNS) Linac has an optimum vacuum system. The vacuum joints between flanges must have reliable seals to minimize the leak rate and meet vacuum and electrical requirements. In addition, it is desirable to simplify the installation and thereby also simplify the maintenance required. This report summarizes an investigation of the metal vacuum seals that include the metal C-seal, Energized Spring seal, Helcoflex Copper Delta seal, Aluminum Delta seal, delta seal with limiting ring, and the prototype of the copper diamond seals. The report also contains the material certifications, design, finite element analysis, and testing for all of these seals. It is a valuable reference for any vacuum system design. To evaluate the suitability of several types of metal seals for use in the SNS Linac and to determine the torque applied on the bolts, a series of vacuum leak rate tests on the metal seals have been completed at Los Alamos Laboratory. A copper plated flange, using the same type of delta seal that was used for testing with the stainless steel flange, has also been studied and tested. A vacuum seal is desired that requires significantly less loading than a standard ConFlat flange with a copper gasket for the coupling cavity assembly. To save the intersegment space the authors use thinner flanges in the design. The leak rate of the thin ConFlat flange with a copper gasket is a baseline for the vacuum test on all seals and thin flanges. A finite element analysis of a long coupling cavity flange with a copper delta seal has been performed in order to confirm the design of the long coupling cavity flange and the welded area of a cavity body with the flange. This analysis is also necessary to predict a potential deformation of the cavity under the combined force of atmospheric pressure and the seating load of the seal. Modeling of this assembly has been achieved using both HKS/Abaqus and COSMOS

  10. Safety considerations in the disposal of disused sealed radioactive sources in borehole facilities

    CERN Document Server

    International Atomic Energ Agency. Vienna

    2003-01-01

    Sealed radioactive sources are used in medicine, industry and research for a wide range of purposes. They can contain different radionuclides in greatly varying amounts. At the end of their useful lives, they are termed 'disused sources' but their activity levels can still be quite high. They are, for all practical purposes, another type of radioactive waste that needs to be disposed of safely. Disused sealed radioactive sources can represent a significant hazard to people if not managed properly. Many countries have no special facilities for the management or disposal of radioactive waste, as they have no nuclear power programmes requiring such facilities. Even in countries with developed nuclear programmes, disused sealed sources present problems as they often fall outside the common categories of radioactive waste for which disposal options have been identified. As a result, many disused sealed sources are kept in storage. Depending on the nature of the storage arrangements, this situation may represent a ...

  11. Capillary Discharge XUV Radiation Source

    Directory of Open Access Journals (Sweden)

    M. Nevrkla

    2009-01-01

    Full Text Available A device producing Z-pinching plasma as a source of XUV radiation is described. Here a ceramic capacitor bank pulse-charged up to 100 kV is discharged through a pre-ionized gas-filled ceramic tube 3.2 mm in diameter and 21 cm in length. The discharge current has amplitude of 20 kA and a rise-time of 65 ns. The apparatus will serve as experimental device for studying of capillary discharge plasma, for testing X-ray optics elements and for investigating the interaction of water-window radiation with biological samples. After optimization it will be able to produce 46.9 nm laser radiation with collision pumped Ne-like argon ions active medium. 

  12. Technology, safety, and costs of decommissioning a reference large irradiator and reference sealed sources

    Energy Technology Data Exchange (ETDEWEB)

    Haffner, D.R.; Villelgas, A.J. [Pacific Northwest Lab., Richland, WA (United States)

    1996-01-01

    This report contains the results of a study sponsored by the US Nuclear Regulatory Commission (NRC) to examine the decommissioning of large radioactive irradiators and their respective facilities, and a broad spectrum of sealed radioactive sources and their respective devices. Conceptual decommissioning activities are identified, and the technology, safety, and costs (in early 1993 dollars) associated with decommissioning the reference large irradiator and sealed source facilities are evaluated. The study provides bases and background data for possible future NRC rulemaking regarding decommissioning, for evaluation of the reasonableness of planned decommissioning actions, and for determining if adequate funds are reserved by the licensees for decommissioning of their large irradiator or sealed source facilities. Another purpose of this study is to provide background and information to assist licensees in planning and carrying out the decommissioning of their sealed radioactive sources and respective facilities.

  13. Characterization and packaging of disused sealed radioactive sources; Caracterizacion y acondicionamiento de fuentes radiactivas selladas en desuso

    Energy Technology Data Exchange (ETDEWEB)

    Aguilar, S.L. [Instituto Boliviano de Ciencia y Tecnologia Nuclear (IBTEN), La Paz (Bolivia, Plurinational State of)

    2013-07-01

    In Bolivia are generated disused sealed sources and radioactive waste resulting from the use of radioactive materials in industrial, research and medicine. The last includes the diagnosis and treatment. Whereas exposure to ionizing radiation is a potential hazard to personnel who applies it, to those who benefit from its use or for the community at large, it is necessary to control the activities in this field. The Instituto Boliviano de Ciencia y Tecnologia Nuclear - IBTEN is working on a regional project from International Atomic Energy Agency - IAEA, RLA/09/062 Project - TSA 4, Strengthening the National Infrastructure and Regulatory Framework for the Safe Management of Radioactive waste in Latin America. This Project has strengthened the regulatory framework regarding the safe management of radioactive waste. The aim of this work was focused primarily on the security aspects in the safe management of disused sealed sources. The tasks are listed below: 1. Characterization of disused sealed sources 2. Preparation for transport to temporary storage 3. Control of all disused radioactive sources. (author)

  14. Installation for producing sealed radioactive sources; Installation de fabrication de sources radioactives scellees

    Energy Technology Data Exchange (ETDEWEB)

    Fradin, J.; Hayoun, C. [Commissariat a l' Energie Atomique, 91 - Saclay (France). Centre d' Etudes Nucleaires

    1969-07-01

    This installation has been designed and built for producing sealed sources of fission elements: caesium 137, strontium 90, promethium 147, ruthenium 106 and cerium 144 in particular. The installation consists of sealed and protected cells, each being assigned to a particular production. The safety and the operational reliability of the equipment are the principal considerations which have governed this work. The report describes the installation and, in particular, the apparatus used as well as the various control devices. In conclusion, a review as presented of six years operation. (authors) [French] Cette installation a ete concue et realisee pour effectuer des fabrications de sources scellees d'elements de fission: caesium 137 - strontium 90 - promethium 147 - ruthenium 106 - cerium 144 en particulier. L'installation est composee de cellules etanches et protegees, chacune d'elles etant affectee a une fabrication particuliere. La securite et la surete de fonctionnement de l'ensemble sont parmi les elements principaux qui ont guide l'etude. Le rapport decrit l'installation et plus particulierement l'appareillage utilise ainsi que les divers controles et commandes. Le bilan de fonctionnement apres 6 ans d'exploitation sert de conclusion. (auteurs)

  15. Storage of low-level radioactive waste and regulatory control of sealed sources in Finland

    Energy Technology Data Exchange (ETDEWEB)

    Rahola, T.; Markkanen, M. [STUK - Radiation and Nuclear Safety Authority, Helsinki (Finland)

    2006-07-01

    This paper is concentrated on the non nuclear low-level radioactive waste. The cornerstone for maintaining radioactive sources under control in Finland is that all practices involving sources are subject to authorization and all licensing information, including information on each individual source, are entered into a register which is continuously updated based on applications and notifications received from the licenses. Experiences during the past twenty years have shown that source-specific records of sources combined with regular inspections at the places of use have prevented efficiency losing control over sealed radioactive sources. The current capacity in the interim storage for State owned waste is not adequate for all used sealed sources and other small user waste which are currently kept in the possession of the licensees. Thus, expansion of the storage capacity and other options for taking care of the small user waste is under consideration. (N.C.)

  16. Mechanical seals

    CERN Document Server

    Mayer, E

    1977-01-01

    Mechanical Seals, Third Edition is a source of practical information on the design and use of mechanical seals. Topics range from design fundamentals and test rigs to leakage, wear, friction and power, reliability, and special designs. This text is comprised of nine chapters; the first of which gives a general overview of seals, including various types of seals and their applications. Attention then turns to the fundamentals of seal design, with emphasis on six requirements that must be considered: sealing effectiveness, length of life, reliability, power consumption, space requirements, and c

  17. Automation system for quality control in manufacture of iodine-125 sealed sources used in brachytherapy

    Energy Technology Data Exchange (ETDEWEB)

    Somessari, Samir L.; Feher, Anselmo; Sprenger, Francisco E.; Rostellato, Maria E.C.M.; Moura, Joao A.; Costa, Osvaldo L.; Calvo, Wilson A.P., E-mail: somessar@ipen.b, E-mail: afeher@ipen.b, E-mail: sprenger@ipen.b, E-mail: elisaros@ipen.b, E-mail: olcosta@ipen.b, E-mail: wapcalvo@ipen.b [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), Sao Paulo, SP (Brazil)

    2011-07-01

    The objective of this work is to develop an automation system for Quality Control in the production of Iodine-125 sealed sources, after undergoing the process of laser beam welding. These sources, also known as Iodine-125 seeds are used, successfully, in the treatment of cancer by brachytherapy, with low-dose rates. Each small seed is composed of a welded titanium capsule with 0.8 mm diameter and 4.5 mm in length, containing Iodine-125 adsorbed on an internal silver wire. The seeds are implanted in the human prostate to irradiate the tumor and treat the cancerous cells. The technology to automate the quality control system in the manufacture of Iodine-125 seeds consists in developing and associate mechanical parts, electronic components and pneumatic circuits to control machines and processes. The automation technology for Iodine-125 seed production developed in this work employs programmable logic controller, step motors, drivers of control, electrical-electronic interfaces, photoelectric sensors, interfaces of communication and software development. Industrial automation plays an important role in the production of Iodine-125 seeds, with higher productivity and high standard of quality, facilitating the implementation and operation of processes with good manufacturing practices. Nowadays, the Radiation Technology Center at IPEN-CNEN/SP imports and distributes 36,000 Iodine-125 seeds per year for clinics and hospitals in the whole country. However, the Brazilian potential market is of 8,000 Iodine-125 seeds per month. Therefore, the local production of these radioactive seeds has become a priority for the Institute, aiming to reduce the price and increase the supply to the population in Brazil. (author)

  18. All-fiber femtosecond Cherenkov radiation source

    DEFF Research Database (Denmark)

    Liu, Xiaomin; Lægsgaard, Jesper; Møller, Uffe

    2012-01-01

    An all-fiber femtosecond source of spectrally isolated Cherenkov radiation is reported, to the best of our knowledge, for the first time. Using a monolithic, self-starting femtosecond Yb-doped fiber laser as the pump source and the combination of photonic crystal fibers as the wave-conversion med......An all-fiber femtosecond source of spectrally isolated Cherenkov radiation is reported, to the best of our knowledge, for the first time. Using a monolithic, self-starting femtosecond Yb-doped fiber laser as the pump source and the combination of photonic crystal fibers as the wave......-conversion medium, we demonstrate milliwatt-level, stable, and tunable Cherenkov radiation at visible wavelengths 580–630 nm, with pulse duration of sub-160-fs, and the 3 dB spectral bandwidth not exceeding 36 nm. Such an all-fiber Cherenkov radiation source is promising for practical applications in biophotonics...

  19. Safety and security management of disused sealed radioactive sources in Thailand

    Science.gov (United States)

    Ya-anant, N.; Nuanjan, P.; Phattanasub, A.; Akharawutchayanon, T.; O-manee, A.; Prasertchiewchan, N.; Benitez-Navarro, J. C.

    2015-05-01

    When sealed radioactive sources are no longer in use, they should be returned back to the country of origin. However, most of them could not be returned to the origin; therefore, disused sealed radioactive sources (DSRS) have to be managed locally to ensure the safety and the security for long term storage before final disposal. The Radioactive Waste Management Center, Thailand Institute of Nuclear Technology, is authorized to operate the treatment, conditioning and storage of DSRS in Thailand. This paper will describe the operational procedures on characterization technique, identifation of unknown sources, volume reduction technique, re-packaging, registration and record keeping of DSRS. The successful results included that the record keeping of DSRS has been developed, and the national inventory of stored DSRS has been made up to date. The results confirmed that the quality control at the DSRS storage facility at Thailand Institute of Nuclear Technology was established and well implemented to ensure safe and secure management.

  20. Research of seal materials adhesion to walls of cavity in enamel and dentin formation by Er laser radiation

    Science.gov (United States)

    Altshuler, Gregory B.; Belikov, Andrei V.; Vlasova, Svetlana N.; Erofeev, Andrew V.

    1994-12-01

    The present work represents the results of research of mechanical strength formed by submillisecond pulses of Er-laser at the border of enamel-seal and dentine-seal in a cavity. Comparative research of an adhesion of three of the most widespread types of modern seal materials (cement, amalgam, polymer) to walls of the laser cavity are conducted. The comparison of `laser adhesion' with adhesion of these materials to the walls of the cavity has been made by the usual mechanical tools. The dependence of free adhesion energy from the geometry of the cavity and energy density of laser radiation is considered. This work informs the reader about the results of research removal efficiency of some modern seal materials. The influence of water-spray on the efficiency of seal materials laser treatment process is considered.

  1. Ionizing radiations management in university, medical and industrial media; La gestion des sources ionisantes en milieux universitaire, medical et industriel

    Energy Technology Data Exchange (ETDEWEB)

    Klein, D. [Universite Technologique de Belfort Montbeliard - LERMPS, 90 - Belfort (France)]|[Universite de Franche Comte, CREST-IRMA, 25 - Montbeliard (France)

    2001-07-01

    The radioactive sources are useful in several areas: medicine, research, measurement laboratories. Severe accidents in the past (Forbach in France 1991, Arequipa, Peru 1999, Goiania, Brazil 1987) remind us of the dangerous character of ionizing radiations. That is why the the management of radioactive sources are so regulated. Radiation protection and legal aspects of sealed and unsealed sources management are evoked, as well as the different official organisms that take a part in their management. (N.C.)

  2. A vacuum-sealed, gigawatt-class, repetitively pulsed high-power microwave source

    Science.gov (United States)

    Xun, Tao; Fan, Yu-wei; Yang, Han-wu; Zhang, Zi-cheng; Chen, Dong-qun; Zhang, Jian-de

    2017-06-01

    A compact L-band sealed-tube magnetically insulated transmission line oscillator (MILO) has been developed that does not require bulky external vacuum pump for repetitive operations. This device with a ceramic insulated vacuum interface, a carbon fiber array cathode, and non-evaporable getters has a base vacuum pressure in the low 10-6 Pa range. A dynamic 3-D Monte-Carlo model for the molecular flow movement and collision was setup for the MILO chamber. The pulse desorption, gas evolution, and pressure distribution were exactly simulated. In the 5 Hz repetition rate experiments, using a 600 kV diode voltage and 48 kA beam current, the average radiated microwave power for 25 shots is about 3.4 GW in 45 ns pulse duration. The maximum equilibrium pressure is below 4.0 × 10-2 Pa, and no pulse shortening limitations are observed during the repetitive test in the sealed-tube condition.

  3. Radiation Safety and Orphan Sources

    Energy Technology Data Exchange (ETDEWEB)

    Janzekovic, H.; Krizman, M. [Slovenian Nuclear Safety Administration, Ljubljana (Slovenia)

    2006-07-01

    The wide spread use of radioactive and particularly of nuclear materials which started in the last century very quickly also demonstrated negative sides. The external exposure and radiotoxicity of these materials could be easily used in a malevolent act. Due to the fact that these materials could not be detected without special equipment designed for that purpose, severe control over their use in all phases of a life cycle is required. An orphan source is a radioactive source which is not under regulatory control, either because it has never been under regulatory or because it has been abandoned, lost, misplaced, stolen or transferred without proper authorization. In the last ten years a few international conferences were dedicated to the improvement of the safety and security of radioactive sources. Three main tasks are focused, the maintenance of data bases related to events with orphan sources and the publications of such events, the preparation of recommendations and guidelines to national regulatory bodies in order to prevent and detect the events related to orphan sources as well as to develop the response strategies to radiological or nuclear emergency, appraisals of the national strategies of radioactive sources control. Concerning Slovenia, strengthening control over orphan sources in Slovenia started after the adoption of new legislation in 2002. It was carried out through several tasks with the aim to prevent orphan sources, as well as to identify the sources which could be potentially orphan sources. The comprehensive methodology was developed by the Slovenian nuclear safety administration (S.N.S.A.) based on international guidelines as well as on the study of national lesson learned cases. The methodology was developed and used in close cooperation with all parties involved, namely other regulatory authorities, police, customs, agency for radioactive waste management (A.R.A.O.), technical support organisations (T.S.O.), users of source, authorised

  4. Standard review plan for applications for sealed source and device evaluations and registrations

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1996-11-01

    The purpose of this document is to provide the reviewer of a request for a sealed source or device safety evaluation with the information and materials necessary to make a determination that the product is acceptable for licensing purposes. It provides the reviewer with a listing of the applicable regulations and industry standards, policies affecting evaluation and registration, certain administrative procedures to be followed, and information on how to perform the evaluation and write the registration certificate. Standard review plans are prepared for the guidance of the Office of Nuclear Material Safety and Safeguards staff responsible for the review of a sealed source or device application. This document is made available to the public as part of the Commission`s policy to inform the nuclear industry and the general public of regulatory procedures and policies. Standard review plans are not substitutes for regulatory guides or the Commission`s regulations and compliance with them is not required.

  5. Evaluation of the sealing properties and TMA study of multilayer PA/PE film treated with e-beam radiation

    Energy Technology Data Exchange (ETDEWEB)

    Ortiz, Angel V.; Gargalaka Junior, Joao [UNIPAC Embalagens Ltda., Sao Paulo, SP (Brazil)]. E-mail: angel.ortiz@unipacnet.com.br; joao.gargalaka@unipacnet.com.br; Wiebeck, Helio [Universidade de Sao Paulo (USP), SP (Brazil). Escola Politecnica]. E-mail: hwiebeck@usp.br

    2007-07-01

    Multilayer films are widely used in the food industry as thermoforming as well as non thermoforming vacuum packaging. In this study a PA6/LDPE multilayer film underwent E-beam radiation and its sealing properties were evaluated over 3 years after the film was irradiated. Packaging materials have been widely processed by ionizing radiation in order to improve their chemical and physical properties and also for sterilization purposes. Basically, flexible packaging manufacturers apply specific radiation doses to promote cross-linking and scission of the polymeric chains and thus obtain alterations in certain properties. While enhancing a specific property, significant losses may result in others. We examined the effects of E-beam radiation on the sealing properties of the multilayer film irradiated with doses up to 127 kGy. Results showed that as doses go up, the sealing strength goes down. The TMA study shows that the softening/melting temperatures of the LDPE layer (sealing layer) varies according to the irradiation doses and helps explain the results of the sealing strength tests. (author)

  6. Soil Monitor: an open source web application for real-time soil sealing monitoring and assessment

    Science.gov (United States)

    Langella, Giuliano; Basile, Angelo; Giannecchini, Simone; Iamarino, Michela; Munafò, Michele; Terribile, Fabio

    2016-04-01

    Soil sealing is one of the most important causes of land degradation and desertification. In Europe, soil covered by impermeable materials has increased by about 80% from the Second World War till nowadays, while population has only grown by one third. There is an increasing concern at the high political levels about the need to attenuate imperviousness itself and its effects on soil functions. European Commission promulgated a roadmap (COM(2011) 571) by which the net land take would be zero by 2050. Furthermore, European Commission also published a report in 2011 providing best practices and guidelines for limiting soil sealing and imperviousness. In this scenario, we developed an open source and an open source based Soil Sealing Geospatial Cyber Infrastructure (SS-GCI) named as "Soil Monitor". This tool merges a webGIS with parallel geospatial computation in a fast and dynamic fashion in order to provide real-time assessments of soil sealing at high spatial resolution (20 meters and below) over the whole Italy. Common open source webGIS packages are used to implement both the data management and visualization infrastructures, such as GeoServer and MapStore. The high-speed geospatial computation is ensured by a GPU parallelism using the CUDA (Computing Unified Device Architecture) framework by NVIDIA®. This kind of parallelism required the writing - from scratch - all codes needed to fulfil the geospatial computation built behind the soil sealing toolbox. The combination of GPU computing with webGIS infrastructures is relatively novel and required particular attention at the Java-CUDA programming interface. As a result, Soil Monitor is smart because it can perform very high time-consuming calculations (querying for instance an Italian administrative region as area of interest) in less than one minute. The web application is embedded in a web browser and nothing must be installed before using it. Potentially everybody can use it, but the main targets are the

  7. Justification Of The Use Of Boreholes For Disposal Of Sealed Radiological Sources

    Energy Technology Data Exchange (ETDEWEB)

    Zarling, John [Los Alamos National Laboratory; Johnson, Peter [Los Alamos National Laboratory

    2008-01-01

    Soon there will be only 14 states in two compacts that are able to dispose of Low Level Waste (LLW): the Northwest and Rocky Mountain compact with disposal options in Richland, Washington, and the Atlantic compact with disposal options in Barnwell, South Carolina. How do states not in one of the two compacts dispose of their LLW? The Off-Site Source Recovery Project can take possession and dispose of some of the unwanted transuranic sources at the Waste Isolation Pilot Plant (WIPP). However, there will be no path forward for states outside of the two compacts for disposal of their non-transuranic LLW. A solution that has been much discussed, debated and researched, but has not been put into wide scale practice, is the borehole disposal concept. It is the author's position that companies that drill and explore for oil have been disposing of sources in borehole-like structures for years. It should be noted that these companies are not purposely disposing of these sources, but the sources are irretrievable and must be abandoned. Additionally, there are Nuclear Regulatory Commission (NRC) regulations that must be followed to seal the well that contains the lost and abandoned source. According to the NRC Event Notification Reports database, there were a minimum of 29 reports of lost and abandoned sources in oil wells between December 1999 and October 2006. The sources were lost at depths between 2,018-18,887 feet, or 600-5,750 meters. The companies that are performing explorations with the aid of sealed radiological sources must follow regulation 10 CFR Part 39. Subsection 15 outlines the procedures that must be followed if sources are determined to be irretrievable and abandoned in place. If the NRC allows and has regulations in place for oil companies, why can't states and/or companies be allowed to dispose of LLW in a similar fashion?

  8. Radiation of superluminal sources in vacuum

    Energy Technology Data Exchange (ETDEWEB)

    Bolotovskii, B.M. [P.N. Lebedev Physical Institute, Leninsky prospect 53, Moscow 119991 (Russian Federation)]. E-mail: bolot@lpi.ru; Serov, A.V. [P.N. Lebedev Physical Institute, Leninsky prospect 53, Moscow 119991 (Russian Federation)]. E-mail: serov@x4u.levedev.ru

    2006-08-15

    Vavilov-Cherenkov radiation is emitted by a charged body uniformly moving in a medium when the body velocity exceeds that of light in the medium. Therefore, it was believed that Vavilov-Cherenkov radiation is impossible in vacuum, because the velocity of any material body cannot exceed the light velocity in vacuum. However, it is possible to realize distributions of charges and currents which propagate with any given velocity. Such a superluminal distribution can be used as a source of Vavilov-Cherenkov radiation in vacuum.

  9. Sustainably Sourced, Thermally Resistant, Radiation Hard Biopolymer

    Science.gov (United States)

    Pugel, Diane

    2011-01-01

    This material represents a breakthrough in the production, manufacturing, and application of thermal protection system (TPS) materials and radiation shielding, as this represents the first effort to develop a non-metallic, non-ceramic, biomaterial-based, sustainable TPS with the capability to also act as radiation shielding. Until now, the standing philosophy for radiation shielding involved carrying the shielding at liftoff or utilizing onboard water sources. This shielding material could be grown onboard and applied as needed prior to different radiation landscapes (commonly seen during missions involving gravitational assists). The material is a bioplastic material. Bioplastics are any combination of a biopolymer and a plasticizer. In this case, the biopolymer is a starch-based material and a commonly accessible plasticizer. Starch molecules are composed of two major polymers: amylase and amylopectin. The biopolymer phenolic compounds are common to the ablative thermal protection system family of materials. With similar constituents come similar chemical ablation processes, with the potential to have comparable, if not better, ablation characteristics. It can also be used as a flame-resistant barrier for commercial applications in buildings, homes, cars, and heater firewall material. The biopolymer is observed to undergo chemical transformations (oxidative and structural degradation) at radiation doses that are 1,000 times the maximum dose of an unmanned mission (10-25 Mrad), indicating that it would be a viable candidate for robust radiation shielding. As a comparison, the total integrated radiation dose for a three-year manned mission to Mars is 0.1 krad, far below the radiation limit at which starch molecules degrade. For electron radiation, the biopolymer starches show minimal deterioration when exposed to energies greater than 180 keV. This flame-resistant, thermal-insulating material is non-hazardous and may be sustainably sourced. It poses no hazardous

  10. Radioactivity determination of sealed pure beta-sources by surface dose measurements and Monte Carlo simulations

    Energy Technology Data Exchange (ETDEWEB)

    Choi, Chang Heon [Interdisciplinary Program in Radiation Applied Life Science, Seoul National University College of Medicine, Seoul (Korea, Republic of); Jung, Seongmoon [Program in Biomedical Radiation Sciences, Department of Transdisciplinary Studies, Graduate School of Convergence Science and Technology, Seoul National University, Seoul (Korea, Republic of); Choi, Kanghyuk; Son, Kwang-Jae; Lee, Jun Sig [Hanaro Applications Research, Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of); Ye, Sung-Joon, E-mail: sye@snu.ac.kr [Interdisciplinary Program in Radiation Applied Life Science, Seoul National University College of Medicine, Seoul (Korea, Republic of); Program in Biomedical Radiation Sciences, Department of Transdisciplinary Studies, Graduate School of Convergence Science and Technology, Seoul National University, Seoul (Korea, Republic of); Center for Convergence Research on Robotics, Advance Institutes of Convergence Technology, Seoul National University, Suwon (Korea, Republic of)

    2016-04-21

    This study aims to determine the activity of a sealed pure beta-source by measuring the surface dose rate using an extrapolation chamber. A conversion factor (cGy s{sup −1} Bq{sup −1}), which was defined as the ratio of surface dose rate to activity, can be calculated by Monte Carlo simulations of the extrapolation chamber measurement. To validate this hypothesis the certified activities of two standard pure beta-sources of Sr/Y-90 and Si/P-32 were compared with those determined by this method. In addition, a sealed test source of Sr/Y-90 was manufactured by the HANARO reactor group of KAERI (Korea Atomic Energy Research Institute) and used to further validate this method. The measured surface dose rates of the Sr/Y-90 and Si/P-32 standard sources were 4.615×10{sup −5} cGy s{sup −1} and 2.259×10{sup −5} cGy s{sup −1}, respectively. The calculated conversion factors of the two sources were 1.213×10{sup −8} cGy s{sup −1} Bq{sup −1} and 1.071×10{sup −8} cGy s{sup −1} Bq{sup −1}, respectively. Therefore, the activity of the standard Sr/Y-90 source was determined to be 3.995 kBq, which was 2.0% less than the certified value (4.077 kBq). For Si/P-32 the determined activity was 2.102 kBq, which was 6.6% larger than the certified activity (1.971 kBq). The activity of the Sr/Y-90 test source was determined to be 4.166 kBq, while the apparent activity reported by KAERI was 5.803 kBq. This large difference might be due to evaporation and diffusion of the source liquid during preparation and uncertainty in the amount of weighed aliquot of source liquid. The overall uncertainty involved in this method was determined to be 7.3%. We demonstrated that the activity of a sealed pure beta-source could be conveniently determined by complementary combination of measuring the surface dose rate and Monte Carlo simulations.

  11. Radiation of superluminal sources in empty space

    Energy Technology Data Exchange (ETDEWEB)

    Bolotovskii, Boris M; Serov, Alexander V [P.N. Lebedev Physics Institute, Russian Academy of Sciences, Moscow (Russian Federation)

    2005-09-30

    We consider the theoretical prerequisites for and experimental papers on the coherent radiation of electromagnetic waves by moving sources whose speed exceeds the speed of light in empty space. Examples of this kind are provided by a light spot or a charged filament incident on an interface between two media. (reviews of topical problems)

  12. Compact high-power terahertz radiation source

    Directory of Open Access Journals (Sweden)

    G. A. Krafft

    2004-06-01

    Full Text Available In this paper a new type of THz radiation source, based on recirculating an electron beam through a high gradient superconducting radio frequency cavity, and using this beam to drive a standard electromagnetic undulator on the return leg, is discussed. Because the beam is recirculated and not stored, short bunches may be produced that radiate coherently in the undulator, yielding exceptionally high average THz power for relatively low average beam power. Deceleration from the coherent emission, and the detuning it causes, limits the charge-per-bunch possible in such a device.

  13. Evaluation of the endodontic apical seal after post insertion by synchrotron radiation microtomography

    Science.gov (United States)

    Contardo, L.; De Luca, M.; Biasotto, M.; Longo, R.; Olivo, A.; Pani, S.; Di Lenarda, R.

    2005-08-01

    The commonly used methods for evaluating the endodontic apical seal, such as longitudinal and transversal section and diaphanization, show some operative difficulties and intrinsic limitation. This study suggests and describes a new method of analysis using a synchrotron radiation microtomography to analyse the root apex after post insertion, creating a three-dimensional image and analysing sections of the specimen every 5 μm. The study was performed at SYRMEP beam line at the Electra Synchrotron in Trieste using monochromatic X-rays of 32 KeV. Eleven monoradicular teeth were prepared using NiTi GT Rotary files instruments to an apical size 20 with conicity .06 and divided in four groups: in G1 ( n=4) and G2 ( n=2), the specimens were endodontically filled with guttapercha and a zinc-oxide sealer, in G3 ( n=3) and G4 ( n=2) guttapercha and a silicon-based sealer were used. An endodontic post was inserted in specimens of groups 1 and 3 following the manufacturer's instructions. Specimens were analysed using monochromatic X-rays of 32 KeV. A CCD detector with pixel dimension pf 5×5 μm 2 was used for the acquisition process. Seven hundred and twenty projections were performed over 180° range using a high-resolution rotator. The projections were reconstructed using standard algorithms for tomographic reconstruction. The apical infiltration was evaluated by verifying if black spots were detectable on the images. The specimens of groups 3 and 4 showed a better apical seal than the ones of groups 1 and 2. Post insertion, when a ZOE-based sealer is used, increases the apical gap even if it does not seem to be clinically relevant and sufficient to be a cause of endodontic failure. The new method for analysis appeared to be effective to detect small defects in endodontic obturation, analysing guttapercha-sealer and sealer-dentin interfaces.

  14. Evaluation of the endodontic apical seal after post insertion by synchrotron radiation microtomography

    Energy Technology Data Exchange (ETDEWEB)

    Contardo, L. [Dipartimento di Scienze, Chirurgiche Specialistiche, University of Trieste, Trieste (Italy)]. E-mail: olivo@ts.infn.it; De Luca, M. [Dipartimento di Scienze, Chirurgiche Specialistiche, University of Trieste, Trieste (Italy); Biasotto, M. [Dipartimento di Scienze, Chirurgiche Specialistiche, University of Trieste, Trieste (Italy); Longo, R. [Dipartment of Physics of the University of Trieste and INFN, Trieste (Italy); Olivo, A. [Dipartment of Physics of the University of Trieste and INFN, Trieste (Italy); Pani, S. [Dipartment of Physics of the University of Trieste and INFN, Trieste (Italy); Di Lenarda, R. [Dipartimento di Scienze, Chirurgiche Specialistiche, University of Trieste, Trieste (Italy)

    2005-08-11

    The commonly used methods for evaluating the endodontic apical seal, such as longitudinal and transversal section and diaphanization, show some operative difficulties and intrinsic limitation. This study suggests and describes a new method of analysis using a synchrotron radiation microtomography to analyse the root apex after post insertion, creating a three-dimensional image and analysing sections of the specimen every 5{mu}m. The study was performed at SYRMEP beam line at the Electra Synchrotron in Trieste using monochromatic X-rays of 32KeV. Eleven monoradicular teeth were prepared using NiTi GT Rotary files instruments to an apical size 20 with conicity .06 and divided in four groups: in G1 (n=4) and G2 (n=2), the specimens were endodontically filled with guttapercha and a zinc-oxide sealer, in G3 (n=3) and G4 (n=2) guttapercha and a silicon-based sealer were used. An endodontic post was inserted in specimens of groups 1 and 3 following the manufacturer's instructions. Specimens were analysed using monochromatic X-rays of 32KeV. A CCD detector with pixel dimension pf 5x5{mu}m{sup 2} was used for the acquisition process. Seven hundred and twenty projections were performed over 180{sup o} range using a high-resolution rotator. The projections were reconstructed using standard algorithms for tomographic reconstruction. The apical infiltration was evaluated by verifying if black spots were detectable on the images. The specimens of groups 3 and 4 showed a better apical seal than the ones of groups 1 and 2. Post insertion, when a ZOE-based sealer is used, increases the apical gap even if it does not seem to be clinically relevant and sufficient to be a cause of endodontic failure. The new method for analysis appeared to be effective to detect small defects in endodontic obturation, analysing guttapercha-sealer and sealer-dentin interfaces.

  15. Prototypes of phosphorus-32 sealed sources for use in Brachytherapy; Prototipo de fuente radiactiva de fosforo para uso medico en braquiterapia

    Energy Technology Data Exchange (ETDEWEB)

    Anaya Garro, Olgger; Vela Mora, Mariano; Revilla Silva, Angel Revilla [Instituto Peruano de Energia Nuclear (IPEN), Lima (Peru)]. E-mail: oanaya@ipen.gob.pe; mvela@ipen.gob.pe; arevilla@ipen.gob.pe

    2005-07-01

    It has developed prototypes of phosphorus-32 sealed sources for use in Brachytherapy. This one was made in two stages, at the first one, we designed and constructed the container (capsule), the filling system and the sealed system; at the second one, we made the irradiation of the capsules containing the 'target'. The prototypes was made of aluminum in cylindrical geometry. During the irradiation test was made using two different dimensions: one of 1 mm outer diameter and 1 cm length and another one of 0.8 mm outer diameter and 5 mm length. They were radiated in the core of the RP-10 research reactor, at 7.93 x10{sup 13} n/cm{sup 2}.s thermal neutron flux during 27 operation cycles. Activities of 144.53 MBq (3.91 mCi) and 107.67 MBq (2.91 mCi) was obtained for each case. This activities are adequate to restenosis and for some tumors treatment. We can observed that the capsules irradiated passed visual inspection in its physical integrity (leakage and geometry). It has been demonstrated, that the beta radiation for his minor power of penetration and its high interaction, causes major local damage to the malignant tissue, minimizing the damage of the healthy surrounding tissues. It has been advisable to use for the treatment of illnesses of the circulatory system and some tumors. At the present, the source of strontium-90 are the most beta ray source used, but of this one are obtained as fission product of uranium target, where valuable radioactive waste is generated, whereas if we were using phosphorus-32 that we propose, radioactive waste would not be generated since it would take place directly as sealed source, for reaction (n, {beta}). (author)

  16. Study of classification and disposed method for disused sealed radioactive source in Korea

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Suk Hoon; Kim, Ju Youl; Lee, Seung Hee [FNC Technology Co., Ltd.,Yongin (Korea, Republic of)

    2016-09-15

    In accordance with the classification system of radioactive waste in Korea, all the disused sealed radioactive sources (DSRSs) fall under the category of EW, VLLW or LILW, and should be managed in compliance with the restrictions for the disposal method. In this study, the management and disposal method are drawn in consideration of half-life of radionuclides contained in the source and A/D value (i.e. the activity A of the source dividing by the D value for the relevant radionuclide, which is used to provide an initial ranking of relative risk for sources) in addition to the domestic classification scheme and disposal method, based on the characteristic analysis and review results of the management practices in IAEA and foreign countries. For all the DSRSs that are being stored (as of March 2015) in the centralized temporary disposal facility for radioisotope wastes, applicability of the derivation result is confirmed through performing the characteristic analysis and case studies for assessing quantity and volume of DSRSs to be managed by each method. However, the methodology derived from this study is not applicable to the following sources; i) DSRSs without information on the radioactivity, ii) DSRSs that are not possible to calculate the specific activity and/or the source-specific A/D value. Accordingly, it is essential to identify the inherent characteristics for each of DSRSs prior to implementation of this management and disposal method.

  17. Minimally radiating sources for personal audio.

    Science.gov (United States)

    Elliott, Stephen J; Cheer, Jordan; Murfet, Harry; Holland, Keith R

    2010-10-01

    In order to reduce annoyance from the audio output of personal devices, it is necessary to maintain the sound level at the user position while minimizing the levels elsewhere. If the dark zone, within which the sound is to be minimized, extends over the whole far field of the source, the problem reduces to that of minimizing the radiated sound power while maintaining the pressure level at the user position. It is shown analytically that the optimum two-source array then has a hypercardioid directivity and gives about 7 dB reduction in radiated sound power, compared with a monopole producing the same on-axis pressure. The performance of other linear arrays is studied using monopole simulations for the motivating example of a mobile phone. The trade-off is investigated between the performance in reducing radiated noise, and the electrical power required to drive the array for different numbers of elements. It is shown for both simulations and experiments conducted on a small array of loudspeakers under anechoic conditions, that both two and three element arrays provide a reasonable compromise between these competing requirements. The implementation of the two-source array in a coupled enclosure is also shown to reduce the electrical power requirements.

  18. Undulators as sources of synchrotron radiation

    Energy Technology Data Exchange (ETDEWEB)

    Krinsky, S.

    1983-01-01

    At the present time the first generation of facilities having electron storage rings designed for and dedicated to synchrotron radiation research are beginning operations in the US, Europe and Japan. The use of wigglers and undulators as enhanced sources of synchrotron radiation plays an important role at all these facilities. Moreover, recently there has been much activity in the design of the next generation machines, which will place even greater, and perhaps exclusive, emphasis on the use of wigglers and undulators. The operation of these insertion devices has been made even more attractive by advances in the design and construction of permanent magnet wigglers and undulators. This reliable and economical technology eliminates the need for more complex superconducting magnets, except to achieve very high magnetic fields for the production of hard photons from relatively low energy rings. We review the spectral properties of the radiation, emphasizing the complementary aspects of time- and frequency-domain analyses. We next study the brightness of the undulator source. Finally, we consider some limitations associated with operating an undulator in a storage ring.

  19. 75 FR 19302 - Radiation Sources on Army Land

    Science.gov (United States)

    2010-04-14

    ... Department of the Army 32 CFR Part 655 RIN 0702-AA58 Radiation Sources on Army Land AGENCY: Department of the... revise its regulations concerning radiation sources on Army land. The Army requires Non-Army agencies...) other Military Departments needing an ARP to bring radioactive sources on Army lands. The Radiation...

  20. 76 FR 6692 - Radiation Sources on Army Land

    Science.gov (United States)

    2011-02-08

    ... Department of the Army 32 CFR Part 655 RIN 0702-AA58 Radiation Sources on Army Land AGENCY: Department of the... regulation concerning radiation sources on Army land. The Army requires non-Army agencies (including their... Permit for Non-Army Agency Radiation Sources on Army Land.'' The Army received no comments on the...

  1. Seals and sealing handbook

    CERN Document Server

    Flitney, Robert K

    2014-01-01

    Seals and Sealing Handbook, 6th Edition provides comprehensive coverage of sealing technology, bringing together information on all aspects of this area to enable you to make the right sealing choice. This includes detailed coverage on the seals applicable to static, rotary and reciprocating applications, the best materials to use in your sealing systems, and the legislature and regulations that may impact your sealing choices. Updated in line with current trends this updated reference provides the theory necessary for you to select the most appropriate seals for the job and with its 'Failur

  2. The adequacy of current import and export controls on sealed radioactive sources.

    Energy Technology Data Exchange (ETDEWEB)

    Longley, Susan W.; Cochran, John Russell; Price, Laura L. (Beta Corporation, Glendale, AZ); Lipinski, Kendra J.

    2003-10-01

    Millions of sealed radioactive sources (SRSs) are being used for a wide variety of beneficial purposes throughout the world. Security experts are now concerned that these beneficial SRSs could be used in a radiological dispersion device to terrorize and disrupt society. The greatest safety and security threat is from those highly radioactive Category 1 and 2 SRSs. Without adequate controls, it may be relatively easy to legally purchase a Category 1 or 2 SRS on the international market under false pretenses. Additionally, during transfer, SRSs are particularly susceptible to theft since the sources are in a shielded and mobile configuration, transportation routes are predictable, and shipments may not be adequately guarded. To determine if government controls on SRS are adequate, this study was commissioned to review the current SRS import and export controls of six countries. Canada, the Russian Federation, and South Africa were selected as the exporting countries, and Egypt, the Philippines, and the United States were selected as importing countries. A detailed review of the controls in each country is presented. The authors found that Canada and Russia are major exporters, and are exporting highly radioactive SRSs without first determining if the recipient is authorized by the receiving country to own and use the SRSs. Available evidence was used to estimate that on average there are tens to possibly hundreds of intercountry transfers of highly radioactive SRSs each day. Based on these and other findings, this reports recommends stronger controls on the export and import of highly radioactive SRSs.

  3. Low frequency interference between short synchrotron radiation sources

    Directory of Open Access Journals (Sweden)

    F. Méot

    2001-06-01

    Full Text Available A recently developed analytical formalism describing low frequency far-field synchrotron radiation (SR is applied to the calculation of spectral angular radiation densities from interfering short sources (edge, short magnet. This is illustrated by analytical calculation of synchrotron radiation from various assemblies of short dipoles, including an “isolated” highest density infrared SR source.

  4. Seeding Coherent Radiation Sources with Sawtooth Modulation

    Energy Technology Data Exchange (ETDEWEB)

    Ratner, Daniel; Chao, Alex; /SLAC

    2012-03-28

    Seed radiation sources have the ability to increase longitudinal coherence, decrease saturation lengths, and improve performance of tapering, polarization control and other FEL features. Typically, seeding schemes start with a simple sinusoidal modulation, which is manipulated to provide bunching at a high harmonic of the original wavelength. In this paper, we consider seeding from sawtooth modulations. The sawtooth creates a clean phase space structure, providing a maximal bunching factor without the need for an FEL interaction. While a pure sawtooth modulation is a theoretical construct, it is possible to approach the waveform by combining two or more of the composite wavelengths. We give examples of sawtooth seeding for HGHG, EEHG and other schemes, and note that the sawtooth modulation may aid in suppression of the microbunching instability.

  5. Interference between source-free radiation and radiation from sources: Particle-like behavior for classical radiation

    Science.gov (United States)

    Boyer, Timothy H.

    2017-09-01

    A simple junior-level electrodynamics problem is used to illustrate the interference between a source-free standing plane wave and a wave generated by a pulse in a current sheet. Depending upon the relative phases between the standing wave and the current pulse and also upon the relative magnitudes, we can find quite different patterns of emitted energy and momentum. If the source gives a large radiation pulse so that the source-free plane wave can be neglected, then the radiation spreads out symmetrically on either side of the current sheet. However, if the radiation sheet gives a pulse with fields comparable to those of the standing wave, then we can find a single radiation pulse moving to the right while the current sheet recoils to the left or the situation with the directions reversed. The example is a crude illustration of particle-like behavior arising from conventional classical electromagnetic behavior in the presence of source-free radiation. The discussion makes contact with the ideas of photons in modern physics.

  6. Deletion of the rnl gene encoding a nick-sealing RNA ligase sensitizes Deinococcus radiodurans to ionizing radiation.

    Science.gov (United States)

    Schmier, Brad J; Chen, Xinguo; Wolin, Sandra; Shuman, Stewart

    2017-04-20

    Deinococcus radiodurans RNA ligase (DraRnl) seals 3΄-OH/5΄-PO4 nicks in duplex nucleic acids in which the 3΄-OH nick terminus consists of two or more ribonucleotides. DraRnl exemplifies a widely distributed Rnl5 family of nick-sealing RNA ligases, the physiological functions of which are uncharted. Here we show via gene knockout that whereas DraRnl is inessential for growth of D. radiodurans, its absence sensitizes the bacterium to killing by ionizing radiation (IR). DraRnl protein is present in exponentially growing and stationary phase cells, but is depleted during the early stages of recovery from 10 kGy of IR and subsequently replenished during the late phase of post-IR genome reassembly. Absence of DraRnl elicts a delay in reconstitution of the 10 kGy IR-shattered D. radiodurans replicons that correlates with the timing of DraRnl replenishment in wild-type cells. Complementation with a catalytically dead mutant highlights that nick sealing activity is important for the radioprotective function of DraRnl. Our findings suggest a scenario in which DraRnl acts at genomic nicks resulting from gap-filling by a ribonucleotide-incorporating repair polymerase. © The Author(s) 2017. Published by Oxford University Press on behalf of Nucleic Acids Research.

  7. Radiological Characterization Technical Report on Californium-252 Sealed Source Transuranic Debris Waste for the Off-Site Source Recovery Project at Los Alamos National Laboratory

    Energy Technology Data Exchange (ETDEWEB)

    Feldman, Alexander [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2014-04-24

    This document describes the development and approach for the radiological characterization of Cf-252 sealed sources for shipment to the Waste Isolation Pilot Plant. The report combines information on the nuclear material content of each individual source (mass or activity and date of manufacture) with information and data on the radionuclide distributions within the originating nuclear material. This approach allows for complete and accurate characterization of the waste container without the need to take additional measurements. The radionuclide uncertainties, developed from acceptable knowledge (AK) information regarding the source material, are applied to the summed activities in the drum. The AK information used in the characterization of Cf-252 sealed sources has been qualified by the peer review process, which has been reviewed and accepted by the Environmental Protection Agency.

  8. [Use of ionizing radiation sources in metallurgy: risk assessment].

    Science.gov (United States)

    Giugni, U

    2012-01-01

    Use of ionizing radiation sources in the metallurgical industry: risk assessment. Radioactive sources and fixed or mobile X-ray equipment are used for both process and quality control. The use of ionizing radiation sources requires careful risk assessment. The text lists the characteristics of the sources and the legal requirements, and contains a description of the documentation required and the methods used for risk assessment. It describes how to estimate the doses to operators and the relevant classification criteria used for the purpose of radiation protection. Training programs must be organized in close collaboration between the radiation protection expert and the occupational physician.

  9. Long-Term Safe Storage and Disposal of Spent Sealed Radioactive Sources in Borehole Type Repositories

    Energy Technology Data Exchange (ETDEWEB)

    Ojovan, M. I.; Dmitriev, S. A.; Sobolev, I. A.

    2003-02-26

    Russian Federation has the leading experience in applying borehole storage/disposal method for SRS. A new immobilization technology for sources being disposed of in underground repositories was mastered by 1986 and since then it is used in the country. This method uses all advantages of borehole type repositories supplementing them with metal encapsulation of sources. Sources being uniformly allocated in the volume of underground vessel are fixed in the metal block hence ensuring long-term safety. The dissipation of radiogenic heat from SRS is considerably improved, radiation fields are reduced, and direct contact of sources to an environment is completely eliminated. The capacity of a typical borehole storage/disposal facility is increased almost 6 times applying metal immobilization. That has made new technology extremely favourable economically. The metal immobilization of SRS is considered as an option in Belarus and Ukraine as well as Bulgaria. Immobilization of sources in metal matrices can be a real solution for retrieval of SRS from inadequate repositories.

  10. Special Analysis for the Disposal of the Materials and Energy Corporation Sealed Sources at the Area 5 Radioactive Waste Management Site

    Energy Technology Data Exchange (ETDEWEB)

    Shott, Gregory [National Security Technologies, LLC. (NSTec), Mercury, NV (United States)

    2017-05-15

    This special analysis (SA) evaluates whether the Materials and Energy Corporation (M&EC) Sealed Source waste stream (PERM000000036, Revision 0) is suitable for shallow land burial (SLB) at the Area 5 Radioactive Waste Management Site (RWMS) on the Nevada National Security Site (NNSS). Disposal of the M&EC Sealed Source waste meets all U.S. Department of Energy (DOE) Manual DOE M 435.1-1, “Radioactive Waste Management Manual,” Chapter IV, Section P performance objectives (DOE 1999). The M&EC Sealed Source waste stream is recommended for acceptance without conditions.

  11. Development of sealed radioactive sources immobilized in epoxy resin for verification of detectors used in nuclear medicine

    Energy Technology Data Exchange (ETDEWEB)

    Tiezzi, Rodrigo; Rostelato, Maria Elisa C.M.; Nagatomi, Helio R.; Zeituni, Calos A.; Benega, Marcos A.G.; Souza, Daiane B. de; Costa, Osvaldo L. da; Souza, Carla D.; Rodrigues, Bruna T.; Souza, Anderson S. de; Peleias Junior, Fernando S.; Santos, Rafael Melo dos; Melo, Emerson Ronaldo de, E-mail: rktiezzi@gmail.com [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), Sao Paulo, SP (Brazil); Karan Junior, Dib [Universidade de Sao Paulo (USP), Sao Paulo, SP (Brazil)

    2015-07-01

    The radioactive sealed sources are used in verification ionization chamber detectors, which measure the activity of radioisotopes used in several areas, such as in nuclear medicine. The measurement of the activity of radioisotopes must be made with accuracy, because it is administered to a patient. To ensure the proper functioning of the ionization chamber detectors, standardized tests are set by the International Atomic Energy Agency (IAEA) and the National Nuclear Energy Commission using sealed radioactive sources of Barium-133, Cesium-137 and Cobalt-57. The tests assess the accuracy, precision, reproducibility and linearity of response of the equipment. The focus of this work was the study and the development of these radioactive sources with standard Barium-133, Cesium-137 and Cobalt-57,using a polymer, in case commercial epoxy resin of diglycidyl ether of bisphenol A (DGEBA) and a curing agent based on modified polyamine diethylenetriamine (DETA), to immobilize the radioactive material. The polymeric matrix has the main function of fix and immobilize the radioactive contents not allowing them to leak within the technical limits required by the standards of radiological protection in the category of characteristics of a sealed source and additionally have the ability to retain the emanation of any gases that may be formed during the manufacture process and the useful life of this artifact. The manufacturing process of a sealed source standard consists of the potting ,into bottle standardized geometry, in fixed volume of a quantity of a polymeric matrix within which is added and dispersed homogeneously to need and exact amount in activity of the radioactive materials standards. Accordingly, a study was conducted for the choice of epoxy resin, analyzing its characteristics and properties. Studies and tests were performed, examining the maximum solubility of the resin in water (acidic solution, simulating the conditions of radioactive solution), loss of mechanical

  12. Indirect detection of radiation sources through direct detection of radiolysis products

    Science.gov (United States)

    Farmer, Joseph C [Tracy, CA; Fischer, Larry E [Los Gatos, CA; Felter, Thomas E [Livermore, CA

    2010-04-20

    A system for indirectly detecting a radiation source by directly detecting radiolytic products. The radiation source emits radiation and the radiation produces the radiolytic products. A fluid is positioned to receive the radiation from the radiation source. When the fluid is irradiated, radiolytic products are produced. By directly detecting the radiolytic products, the radiation source is detected.

  13. Detailed observations of the source of terrestrial narrowband electromagnetic radiation

    Science.gov (United States)

    Kurth, W. S.

    1982-01-01

    Detailed observations are presented of a region near the terrestrial plasmapause where narrowband electromagnetic radiation (previously called escaping nonthermal continuum radiation) is being generated. These observations show a direct correspondence between the narrowband radio emissions and electron cyclotron harmonic waves near the upper hybrid resonance frequency. In addition, electromagnetic radiation propagating in the Z-mode is observed in the source region which provides an extremely accurate determination of the electron plasma frequency and, hence, density profile of the source region. The data strongly suggest that electrostatic waves and not Cerenkov radiation are the source of the banded radio emissions and define the coupling which must be described by any viable theory.

  14. Separation of radiation from two sources from their known radiated sum field

    DEFF Research Database (Denmark)

    Laitinen, Tommi; Pivnenko, Sergey

    2011-01-01

    This paper presents a technique for complete and exact separation of the radiated fields of two sources (at the same frequency) from the knowledge of their radiated sum field. The two sources can be arbitrary but it must be possible to enclose the sources inside their own non-intersecting minimum...

  15. Incidents with hazardous radiation sources; Zwischenfaelle mit gefaehrlichen Strahlenquellen

    Energy Technology Data Exchange (ETDEWEB)

    Schoenhacker, Stefan [Bundesministerium fuer Inneres, Traiskirchen (Austria). Abt. 1/9 - Zivilschutzschule

    2016-07-01

    Incidents with hazardous radiation sources can occur in any country, even those without nuclear facilities. Preparedness for such incidents is supposed to fulfill globally agreed minimum standards. Incidents are categorized in incidents with licensed handling of radiation sources as for material testing, transport accidents of hazardous radiation sources, incidents with radionuclide batteries, incidents with satellites containing radioactive inventory, incidents wit not licensed handling of illegally acquired hazardous radiation sources. The emergency planning in Austria includes a differentiation according to the consequences: incidents with release of radioactive materials resulting in restricted contamination, incidents with release of radioactive materials resulting in local contamination, and incidents with the hazard of e@nhanced exposure due to the radiation source.

  16. Sound power radiated by sources in diffuse fields

    DEFF Research Database (Denmark)

    Polack, Jean-Dominique

    2000-01-01

    Sound power radiated by sources at low frequency notoriously depends on source position. We sampled the sound field of a rectangular room at 18 microphone and 4 source positions. Average power spectra were extrapolated from the reverberant field, taking into account the frequency dependent reverb...... reverberation times. They reveal fluctuations that depend on source position and extend far above Schroeder frequency....

  17. Radiation protection procedures and dose to the staff in brachytherapy with permanent implant of the sources

    Energy Technology Data Exchange (ETDEWEB)

    Tosi, G.; Cattani, F.

    2002-07-01

    The treatment of intra capsular prostate cancers with the permanent implantation of low energy sealed radioactive sources (''103 Pd-''125I) offers the same probability of curing the tumours as surgery and external-beam radiotherapy with a minimum incidence of unwanted side-effects. The first attempts of using sealed sources for treating prostate cancers go back to 1917, when Barringer reported the results obtained with the implant of ''236Ra needles. Beginning from that period the interest for prostate brachytherapy has shown a fluctuating trend, due especially to the technological possibilities and to the status of the alternative treatment modalities (surgery, external radiotherapy). The main reason of the substantial failure of brachytherapy as compared to the two other treatment modalities had two main causes: the energy, too high ( E{approx_equal} 840 keV), of {gamma}-radiation emitted by ''226 Ra in equilibrium with its decay products and the lack of imaging techniques able to visualize with sufficient accuracy both the prostate and the arrangement, inside it, of the radioactive sources. The employ of low energy {gamma}-emitting radionuclides began in 1974, when Whitmore et al. working at the Sloan Kettering Memorial Cancer Hospital of New York suggested the use of ''125 I sealed sources for the realisation of interstitial permanent implants. Also this attempt, though reducing the side effects typical of the surgical intervention (incontinence, impotence), did non give the expected results in terms of local control of the disease and, as a consequence, of the survival's length. This partial failure was attributed to the fact that, in most cases the dose distribution inside the target volume was not homogeneous, due to the inadequacy of the available imaging techniques used for checking the real position of the sources, during their manual insertion in the tissues. In the last ten years,however, great

  18. Seals and sealing handbook

    CERN Document Server

    Flitney, Robert K

    2007-01-01

    Wherever machinery operates there will be seals of some kind ensuring that the machine remains lubricated, the fluid being pumped does not leak, or the gas does not enter the atmosphere. Seals are ubiquitous, in industry, the home, transport and many other places. This 5th edition of a long-established title covers all types of seal by application: static, rotary, reciprocating etc. The book bears little resemblance to its predecessors, and Robert Flitney has re-planned and re-written every aspect of the subject. No engineer, designer or manufacturer of seals can afford to be without this uniq

  19. Introduction to radiation protection practical knowledge for handling radioactive sources

    CERN Document Server

    Grupen, Claus

    2010-01-01

    The book presents an accessible account of the sources of ionising radiation and the methods of radiation protection. The basics of nuclear physics which are directly related to radiation protection are briefly discussed. The book describes the units of radiation protection, the measurement techniques, biological effects of radiation, environmental radiation, and many applications of radiation. For each chapter there is a problem section with full solutions. A detailed glossary and many useful information in appendixes complete the book. The author has addressed the issue of internationality to make sure that the text and, in particular, the complicated regulations can be easily interpreted not only in Europe and the United States but also in other countries. The subject of radiation protection requires a certain amount of mathematics. For those who have forgotten the basic rules of calculus a short refresher course in the form of a mathematical appendix is added.

  20. Food source and residual efficacy of chlorfenapyr on sealed and unsealed concrete

    Science.gov (United States)

    Adult Tribolium castaneum (Herbst), the red flour beetle, were exposed at 1 day, and 2, 4, and 6 weeks post-treatment on sealed and unsealed concrete arenas treated with chlorfenapyr at rates of 2.8, 6.9, 13.5, 20.6, 27.5 mg active ingredient/m2. Beetles were held either with or without flour, and a...

  1. Stochastic electromagnetic radiation of complex sources

    NARCIS (Netherlands)

    Naus, H.W.L.

    2007-01-01

    The emission of electromagnetic radiation by localized complex electric charge and current distributions is studied. A statistical formalism in terms of general dynamical multipole fields is developed. The appearing coefficients are treated as stochastic variables. Hereby as much as possible a

  2. Search for Artificial Stellar Sources of Infrared Radiation.

    Science.gov (United States)

    Dyson, F J

    1960-06-03

    If extraterrestrial intelligent beings exist and have reached a high level of technical development, one by-product of their energy metabolism is likely to be the large-scale conversion of starlight into far-infrared radiation. It is proposed that a search for sources of infrared radiation should accompany the recently initiated search for interstellar radio communications.

  3. Post-closure safety assessment of near surface disposal facilities for disused sealed radioactive sources

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Seunghee; Kim, Juyoul, E-mail: gracemi@fnctech.com

    2017-03-15

    Highlights: • Post-closure safety assessment of near surface disposal facility for DSRS was performed. • Engineered vault and rock-cavern type were considered for normal and well scenario. • {sup 14}C, {sup 226}Ra, {sup 241}Am were primary nuclides contributing large portion of exposure dose. • Near surface disposal of DSRSs containing {sup 14}C, {sup 226}Ra and {sup 241}Am should be restricted. - Abstract: Great attention has been recently paid to the post-closure safety assessment of low- and intermediate-level radioactive waste (LILW) disposal facility for disused sealed radioactive sources (DSRSs) around the world. Although the amount of volume of DSRSs generated from industry, medicine and research and education organization was relatively small compared with radioactive wastes from commercial nuclear power plants, some DSRSs can pose a significant hazard to human health due to their high activities and long half-lives, if not appropriately managed and disposed. In this study, post-closure safety assessment was carried out for DSRSs generated from 1991 to 2014 in Korea in order to ensure long-term safety of near surface disposal facilities. Two kinds of disposal options were considered, i.e., engineered vault type disposal facility and rock-cavern type disposal facility. Rock-cavern type disposal facility has been under operation in Gyeongju city, republic of Korea since August 2015 and engineered vault type disposal facility will be constructed until December 2020 in the vicinity of rock-cavern disposal facility. Assessment endpoint was individual dose to the member of critical group, which was modeled by GoldSim, which has been widely used as probabilistic risk analysis software based on Monte Carlo simulation in the area of safety assessment of radioactive waste facilities. In normal groundwater scenario, the maximum exposure dose was extremely low, approximately 1 × 10{sup −7} mSv/yr, for both disposal options and satisfied the regulatory limit

  4. ZrCo as a new H(2) storage and getter for Lyman-α radiation sources.

    Science.gov (United States)

    Woyke, T; Schiller, C; Schmidt, U; Schober, T; Zöger, M

    1995-01-01

    In the past, in sealed-off Lyman-α radiation sources (121.57 nm), uranium hydride was used as the hydrogen reservoir. We found that the zirconium-cobalt alloy ZrCo, which has similar thermodynamic properties, can also be used for hydrogen storage in such lamps. Like uranium, ZrCo acts as a getter for atmospheric contaminants. The advantage of the use of ZrCo lies in much easier and safer handling during production and disposal of the lamps. Using ZrCo, we succeeded in producing radiation sources with a large Lyman-α radiation output and high spectral purity, which were successfully applied in a Lyman-α fluorescence hygrometer for stratospheric observations.

  5. Radiation Source Mapping with Bayesian Inverse Methods

    Science.gov (United States)

    Hykes, Joshua Michael

    We present a method to map the spectral and spatial distributions of radioactive sources using a small number of detectors. Locating and identifying radioactive materials is important for border monitoring, accounting for special nuclear material in processing facilities, and in clean-up operations. Most methods to analyze these problems make restrictive assumptions about the distribution of the source. In contrast, the source-mapping method presented here allows an arbitrary three-dimensional distribution in space and a flexible group and gamma peak distribution in energy. To apply the method, the system's geometry and materials must be known. A probabilistic Bayesian approach is used to solve the resulting inverse problem (IP) since the system of equations is ill-posed. The probabilistic approach also provides estimates of the confidence in the final source map prediction. A set of adjoint flux, discrete ordinates solutions, obtained in this work by the Denovo code, are required to efficiently compute detector responses from a candidate source distribution. These adjoint fluxes are then used to form the linear model to map the state space to the response space. The test for the method is simultaneously locating a set of 137Cs and 60Co gamma sources in an empty room. This test problem is solved using synthetic measurements generated by a Monte Carlo (MCNP) model and using experimental measurements that we collected for this purpose. With the synthetic data, the predicted source distributions identified the locations of the sources to within tens of centimeters, in a room with an approximately four-by-four meter floor plan. Most of the predicted source intensities were within a factor of ten of their true value. The chi-square value of the predicted source was within a factor of five from the expected value based on the number of measurements employed. With a favorable uniform initial guess, the predicted source map was nearly identical to the true distribution

  6. Feed network and electromagnetic radiation source

    Science.gov (United States)

    Ardavan, Arzhang; Singleton, John; Linehan, Kevin E.; Ardavan, Houshang; Schmidt-Zwiefel, Andrea Caroline

    2017-01-17

    An antenna may include a volume polarization current radiator and a feed network. The volume polarization current radiator, includes a dielectric solid (such as a dielectric strip), and a plurality of closely-spaced excitation elements (24), each excitation element (24) being configured to induce a volume polarization current distribution in the dielectric solid proximate to the excitation element when a voltage is applied to the excitation element. The feed network is coupled to the volume polarization current radiator. The feed network also includes a plurality of passive power divider elements (32) and a plurality of passive delay elements (d1-d6) coupling the first port (30) and the plurality of second ports (108, 109, 164), the plurality of power divider elements (32) and the plurality of phase delay elements (d1-d6) being configured such that a radio-frequency signal that is applied to the first port (30) experiences a progressive change of phase as it is coupled to the plurality of second ports (108, 109, 164) so as to cause the volume polarization current distribution to propagate along the dielectric solid.

  7. Elastic Wave Radiation from a Line Source of Finite Length

    Energy Technology Data Exchange (ETDEWEB)

    Aldridge, D.F.

    1998-11-04

    Straightforward algebraic expressions describing the elastic wavefield produced by a line source of finite length are derived in circular cylindrical coordinates. The surrounding elastic medium is assumed to be both homogeneous and isotropic, anc[ the source stress distribution is considered axisymmetic. The time- and space-domain formulae are accurate at all distances and directions from the source; no fa-field or long-wavelength assumptions are adopted for the derivation. The mathematics yield a unified treatment of three different types of sources: an axial torque, an axial force, and a radial pressure. The torque source radiates only azirnuthally polarized shear waves, whereas force and pressure sources generate simultaneous compressional and shear radiation polarized in planes containing the line source. The formulae reduce to more familiar expressions in the two limiting cases where the length of the line source approaches zero and infinity. Far-field approximations to the exact equations indicate that waves radiated parallel to the line source axI.s are attenuated relative to those radiated normal to the axis. The attenuation is more severe for higher I?equencies and for lower wavespeeds. Hence, shear waves are affected more than compressional waves. This fi-equency- and directiondependent attenuation is characterized by an extremely simple mathematical formula, and is readily apparent in example synthetic seismograms.

  8. Mobile unit for high active spent radiation sources immobilization

    Energy Technology Data Exchange (ETDEWEB)

    Ojovan, M.I.; Sobolev, I.A.; Kachalov, M.B.; Arustamov, A.E.; Shiryaev, V.V.; Semenov, K.N.; Timofeev, E.M.; Stephanovsky, S.V. [Moscow Scientific and Industrial Association Radon, Sergiev Posad (Russian Federation). Dept. of Engineering Supply

    1993-12-31

    A new method of solid high active waste (spent radiation sources) immobilization was developed. It provides the inclusion of the spent radiation sources into the metal matrix directly in the underground repositories. The radiation shielding of the repositories is used for the safety. The method provides the preparation of the metal melt outside of repository. In this way the action of high temperature on the waste is minimal as well as the volatilization of the radio nuclei. A special Mobile Unit for High Active Spent Radiation Sources immobilization was designed. It consists of some modules which are easily assembled on the repositories. The new technology and Mobile Unit are used by Scientific and Industrial Association ``Radon`` beginning 1986 on industrial scale.

  9. Solar radiation data sources, applications, and network design

    Energy Technology Data Exchange (ETDEWEB)

    None

    1978-04-01

    A prerequisite to considering solar energy projects is to determine the requirements for information about solar radiation to apply to possible projects. This report offers techniques to help the reader specify requirements in terms of solar radiation data and information currently available, describes the past and present programs to record and present information to be used for most requirements, presents courses of action to help the user meet his needs for information, lists sources of solar radiation data and presents the problems, costs, benefits and responsibilities of programs to acquire additional solar radiation data. Extensive background information is provided about solar radiation data and its use. Specialized information about recording, collecting, processing, storing and disseminating solar radiation data is given. Several Appendices are included which provide reference material for special situations.

  10. Open Source Radiation Hardened by Design Technology

    Science.gov (United States)

    Shuler, Robert

    2016-01-01

    The proposed technology allows use of the latest microcircuit technology with lowest power and fastest speed, with minimal delay and engineering costs, through new Radiation Hardened by Design (RHBD) techniques that do not require extensive process characterization, technique evaluation and re-design at each Moore's Law generation. The separation of critical node groups is explicitly parameterized so it can be increased as microcircuit technologies shrink. The technology will be open access to radiation tolerant circuit vendors. INNOVATION: This technology would enhance computation intensive applications such as autonomy, robotics, advanced sensor and tracking processes, as well as low power applications such as wireless sensor networks. OUTCOME / RESULTS: 1) Simulation analysis indicates feasibility. 2)Compact voting latch 65 nanometer test chip designed and submitted for fabrication -7/2016. INFUSION FOR SPACE / EARTH: This technology may be used in any digital integrated circuit in which a high level of resistance to Single Event Upsets is desired, and has the greatest benefit outside low earth orbit where cosmic rays are numerous.

  11. Special Analysis for the Disposal of the Neutron Products Incorporated Sealed Source Waste Stream at the Area 5 Radioactive Waste Management Site, Nevada National Security Site, Nye County, Nevada

    Energy Technology Data Exchange (ETDEWEB)

    None, None

    2014-08-31

    The purpose of this special analysis (SA) is to determine if the Neutron Products Incorporated (NPI) Sealed Sources waste stream (DRTK000000056, Revision 0) is suitable for disposal by shallow land burial (SLB) at the Area 5 Radioactive Waste Management Site (RWMS). The NPI Sealed Sources waste stream consists of 850 60Co sealed sources (Duratek [DRTK] 2013). The NPI Sealed Sources waste stream requires a special analysis (SA) because the waste stream 60Co activity concentration exceeds the Nevada National Security Site (NNSS) Waste Acceptance Criteria (WAC) Action Levels.

  12. Exposure of the Spanish population to radiation from natural sources

    Energy Technology Data Exchange (ETDEWEB)

    Garcia-Talavera, M.; Suarez, E.; Matarranz, J.L.; Salas, R.; Ramos, L. [Consejo de Seguridad Nuclear. Justo Dorado, Madrid (Spain)

    2006-07-01

    We have assessed the exposure of the Spanish population to natural radiation sources. The annual average effective dose is estimated to be 2.38 mSv, taking into account contributions from cosmic radiation (13.8%), terrestrial gamma radiation (39%), radon and thoron inhalation (34%) and ingestion (13.2%). Cosmic radiation doses were calculated from town altitude data. Terrestrial gamma ray exposure outdoors was derived from the M.A.R.N.A. (natural gamma radiation map of Spain). Indoor gamma ray exposure was calculated by multiplying the corresponding outdoor value conversion factor, which was obtained by a linear least-squares fit of experimental measurements. Radon doses were estimated from national surveys carried out throughout the country. To assess doses by ingestion of water and foodstuffs we considered the results from a detailed study on consumption habits by age and geographical area in Spain, promoted by C.S.N., and average radioactivity values from UNSCEAR. (authors)

  13. Feasibility of sealed D-T neutron generator as neutron source for liver BNCT and its beam shaping assembly.

    Science.gov (United States)

    Liu, Zheng; Li, Gang; Liu, Linmao

    2014-04-01

    This paper involves the feasibility of boron neutron capture therapy (BNCT) for liver tumor with four sealed neutron generators as neutron source. Two generators are placed on each side of the liver. The high energy of these emitted neutrons should be reduced by designing a beam shaping assembly (BSA) to make them useable for BNCT. However, the neutron flux decreases as neutrons pass through different materials of BSA. Therefore, it is essential to find ways to increase the neutron flux. In this paper, the feasibility of using low enrichment uranium as a neutron multiplier is investigated to increase the number of neutrons emitted from D-T neutron generators. The neutron spectrum related to our system has a proper epithermal flux, and the fast and thermal neutron fluxes comply with the IAEA recommended values. Copyright © 2014 Elsevier Ltd. All rights reserved.

  14. MCNP model for the many KE-Basin radiation sources

    Energy Technology Data Exchange (ETDEWEB)

    Rittmann, P.D.

    1997-05-21

    This document presents a model for the location and strength of radiation sources in the accessible areas of KE-Basin which agrees well with data taken on a regular grid in September of 1996. This modelling work was requested to support dose rate reduction efforts in KE-Basin. Anticipated fuel removal activities require lower dose rates to minimize annual dose to workers. With this model, the effects of component cleanup or removal can be estimated in advance to evaluate their effectiveness. In addition, the sources contributing most to the radiation fields in a given location can be identified and dealt with.

  15. ELBE Center for High-Power Radiation Sources

    Directory of Open Access Journals (Sweden)

    Peter Dr. Michel

    2016-01-01

    Full Text Available In the ELBE Center for High-Power Radiation Sources, the superconducting linear electron accelerator ELBE, serving  two free electron lasers, sources for intense coherent THz radiation, mono-energetic positrons, electrons, γ-rays, a neutron time-of-flight system as well as two synchronized ultra-short pulsed Petawatt laser systems are collocated. The characteristics of these beams make the ELBE center a unique research instrument for a variety of external users in fields ranging from material science over nuclear physics to cancer research, as well as scientists of the Helmholtz-Zentrum Dresden-Rossendorf (HZDR.

  16. Standard Syllabus for Postgraduate Educational Courses in Radiation Protection and the Safe use of Radiation Sources

    Energy Technology Data Exchange (ETDEWEB)

    Arias, C.; Biaggio, A.; Nasazzi, N.

    2004-07-01

    The International Atomic Energy Agency (IAEA) published the Standard Syllabus for Post Graduate Educational Courses in Radiation Protection and the Safety of Radiation Sources in 2002. Along more than two decades, Argentina has obtained valuable experience on building professional knowledge at postgraduate level in Radiation Protection and Nuclear Safety. Such experience made advisable to review the IAEA Standard Syllabus and to modify it accordingly. The whole content of the Standard Syllabus is included in the syllabus developed for the Argentinean Regional Post Graduate Course in Radiation Protection and Safety of Radiation Sources. But a few additional topics were incorporated and changes were introduced in the sequence of subjects. The paper describes those modifications and explains the pedagogic motivations that induce them. (Author) 3 refs.

  17. Glass sealing

    Energy Technology Data Exchange (ETDEWEB)

    Brow, R.K.; Kovacic, L.; Chambers, R.S. [Sandia National Labs., Albuquerque, NM (United States)

    1996-04-01

    Hernetic glass sealing technologies developed for weapons component applications can be utilized for the design and manufacture of fuel cells. Design and processing of of a seal are optimized through an integrated approach based on glass composition research, finite element analysis, and sealing process definition. Glass sealing procedures are selected to accommodate the limits imposed by glass composition and predicted calculations.

  18. Ultrabroadband terahertz source and beamline based on coherent transition radiation

    Directory of Open Access Journals (Sweden)

    S. Casalbuoni

    2009-03-01

    Full Text Available Coherent transition radiation (CTR in the THz regime is an important diagnostic tool for analyzing the temporal structure of the ultrashort electron bunches needed in ultraviolet and x-ray free-electron lasers. It is also a powerful source of such radiation, covering an exceptionally broad frequency range from about 200 GHz to 100 THz. At the soft x-ray free-electron laser FLASH we have installed a beam transport channel for transition radiation (TR with the intention to guide a large fraction of the radiation to a laboratory outside the accelerator tunnel. The radiation is produced on a screen inside the ultrahigh vacuum beam pipe of the linac, coupled out through a diamond window and transported to the laboratory through an evacuated tube equipped with five focusing and four plane mirrors. The design of the beamline has been based on a thorough analysis of the generation of TR on metallic screens of limited size. The optical propagation of the radiation has been computed taking into account the effects of near-field (Fresnel diffraction. The theoretical description of the TR source is presented in the first part of the paper, while the design principles and the technical layout of the beamline are described in the second part. First experimental results demonstrate that the CTR beamline covers the specified frequency range and preserves the narrow time structure of CTR pulses emitted by short electron bunches.

  19. Ideal radiation source for plasma spectroscopy generated by laser ablation

    Science.gov (United States)

    Hermann, Jörg; Grojo, David; Axente, Emanuel; Gerhard, Christoph; Burger, Miloš; Craciun, Valentin

    2017-11-01

    Laboratory plasmas inherently exhibit temperature and density gradients leading to complex investigations. We show that plasmas generated by laser ablation can constitute a robust exception to this. Supported by emission features not observed with other sources, we achieve plasmas of various compositions which are both uniform and in local thermodynamic equilibrium. These properties characterize an ideal radiation source opening multiple perspectives in plasma spectroscopy. The finding also constitutes a breakthrough in the analytical field as fast analyses of complex materials become possible.

  20. Plasma lasers (a strong source of coherent radiation in astrophysics)

    Science.gov (United States)

    Papadopoulos, K.

    1981-01-01

    The generation of electromagnetic radiation from the free energy available in electron streams is discussed. The fundamental principles involved in a particular class of coherent plasma radiation sources, i.e., plasma lasers, are reviewed, focusing on three wave coupling, nonlinear parametric instabilities, and negative energy waves. The simplest case of plasma lasers, that of an unmagnetized plasma containing a finite level of density fluctuations and electrons streaming with respect to the ions, is dealt with. A much more complicated application of plasma lasers to the case of auroral kilometric radiation is then examined. The concept of free electron lasers, including the role of relativistic scattering, is elucidated. Important problems involving the escape of the excited radiation from its generation region, effects due to plasma shielding and nonlinear limits, are brought out.

  1. Portable radiation detection system for pulsed high energy photon sources

    Energy Technology Data Exchange (ETDEWEB)

    Harker, Y.D.; Lawrence, R.S.; Yoon, W.Y. [Idaho National Engineering Lab, Idaho Falls, ID (United States)] [and others

    1994-12-31

    Portable, battery-operated, radiation detection systems for measuring the intensity and energy characteristics of intense, pulsed photon sources (either high energy X-ray or gamma) have been developed at the Idaho National Engineering Laboratory. These field-deployable, suitcase-sized detection units are designed to measure and record the characteristics of a single radiation burst or multiple bursts from a pulsed ionizing radiation source. The recorded information can then be analyzed on a simple laptop computer at a location remote from the detection system and completely independent of the ongoing data acquisition process. Two detection unit designs are described. The first, called the MARK-1, has eight bismuth germanate (BGO) radiation detectors. Four of which are unshielded and have different thicknesses (diameters). The remaining four are the same size as the largest unshielded detector but have different thicknesses of lead shielding surrounding each detector. The second unit design, called the MARK-1 A, utilizes the same detection methodology as the MARK-1 but has ten BGO detectors instead of eight and utilizes a different method of amplifying detector signals enabling reduced overall size and weight of the detection unit. Both the detection system designs have sensitivity ranges from 3 x 10{sup {minus}9} cGy to 9 x 10{sup {minus}5} cGy per radiation burst. Experimental detection results will be presented and discussed along the systems` potential for commercial applications.

  2. Light-emitting diodes as a radiation source for plants

    Science.gov (United States)

    Bula, R. J.; Morrow, R. C.; Tibbitts, T. W.; Barta, D. J.; Ignatius, R. W.; Martin, T. S.

    1991-01-01

    Development of a more effective radiation source for use in plant-growing facilities would be of significant benefit for both research and commercial crop production applications. An array of light-emitting diodes (LEDs) that produce red radiation, supplemented with a photosynthetic photon flux (PPF) of 30 micromoles s-1 m-2 in the 400- to 500-nm spectral range from blue fluorescent lamps, was used effectively as a radiation source for growing plants. Growth of lettuce (Lactuca sativa L. Grand Rapids') plants maintained under the LED irradiation system at a total PPF of 325 micromoles s-1 m-2 for 21 days was equivalent to that reported in the literature for plants grown for the same time under cool-white fluorescent and incandescent radiation sources. Characteristics of the plants, such as leaf shape, color, and texture, were not different from those found with plants grown under cool-white fluorescent lamps. Estimations of the electrical energy conversion efficiency of a LED system for plant irradiation suggest that it may be as much as twice that published for fluorescent systems.

  3. Nuisance Source Population Modeling for Radiation Detection System Analysis

    Energy Technology Data Exchange (ETDEWEB)

    Sokkappa, P; Lange, D; Nelson, K; Wheeler, R

    2009-10-05

    A major challenge facing the prospective deployment of radiation detection systems for homeland security applications is the discrimination of radiological or nuclear 'threat sources' from radioactive, but benign, 'nuisance sources'. Common examples of such nuisance sources include naturally occurring radioactive material (NORM), medical patients who have received radioactive drugs for either diagnostics or treatment, and industrial sources. A sensitive detector that cannot distinguish between 'threat' and 'benign' classes will generate false positives which, if sufficiently frequent, will preclude it from being operationally deployed. In this report, we describe a first-principles physics-based modeling approach that is used to approximate the physical properties and corresponding gamma ray spectral signatures of real nuisance sources. Specific models are proposed for the three nuisance source classes - NORM, medical and industrial. The models can be validated against measured data - that is, energy spectra generated with the model can be compared to actual nuisance source data. We show by example how this is done for NORM and medical sources, using data sets obtained from spectroscopic detector deployments for cargo container screening and urban area traffic screening, respectively. In addition to capturing the range of radioactive signatures of individual nuisance sources, a nuisance source population model must generate sources with a frequency of occurrence consistent with that found in actual movement of goods and people. Measured radiation detection data can indicate these frequencies, but, at present, such data are available only for a very limited set of locations and time periods. In this report, we make more general estimates of frequencies for NORM and medical sources using a range of data sources such as shipping manifests and medical treatment statistics. We also identify potential data sources for industrial

  4. Blackbody radiation sources for the IR spectral range

    Science.gov (United States)

    Ogarev, S. A.; Morozova, S. P.; Katysheva, A. A.; Lisiansky, B. E.; Samoylov, M. L.

    2013-09-01

    Metrological radiometric facilities for optoelectronic instruments calibration utilize in terms of standards as radiation detectors in a form of cryogenic radiometers (CR), so as radiation sources. However in practice, there are no CR working within IR spectral range. An alternative way of radiometric calibration in middle and far IR ranges is to develop a parametric series of standard radiation sources - blackbody (BB) models. The paper describes some of BBs developed at VNIIOFI for the last time [1] from cryogenic (80 K to 200 K), to low (about 200 K to 400 K) and medium (400 K to 700 K) temperature regions for calibration of the IR instruments under cryogenic-vacuum conditions. These BBs are presented by models of both types: variable-temperature and based on fixed points of Ga or In. BBs are characterized with high temperature uniformity and stability. Copper and aluminum alloys are used as the radiation cavity materials. The required value of emissivity ɛλ is achieved by using different black coatings. Low-temperature and cryogenic BBs are based on the principles of indirect multi-zone electric heating (with heat isolation from LN2 cooling loop, or by using an external liquid thermostat with circulating heat-transfer agent. The principles of operation, design and test results of BBs are described.

  5. Blackbody radiation sources for the IR spectral range

    Energy Technology Data Exchange (ETDEWEB)

    Ogarev, S. A.; Morozova, S. P.; Katysheva, A. A.; Lisiansky, B. E.; Samoylov, M. L. [All-Russian Research Institute for Optical and Physical Measurements (VNIIOFI), Moscow (Russian Federation)

    2013-09-11

    Metrological radiometric facilities for optoelectronic instruments calibration utilize in terms of standards as radiation detectors in a form of cryogenic radiometers (CR), so as radiation sources. However in practice, there are no CR working within IR spectral range. An alternative way of radiometric calibration in middle and far IR ranges is to develop a parametric series of standard radiation sources - blackbody (BB) models. The paper describes some of BBs developed at VNIIOFI for the last time [1] from cryogenic (80 K to 200 K), to low (about 200 K to 400 K) and medium (400 K to 700 K) temperature regions for calibration of the IR instruments under cryogenic-vacuum conditions. These BBs are presented by models of both types: variable-temperature and based on fixed points of Ga or In. BBs are characterized with high temperature uniformity and stability. Copper and aluminum alloys are used as the radiation cavity materials. The required value of emissivity ε{sub λ} is achieved by using different black coatings. Low-temperature and cryogenic BBs are based on the principles of indirect multi-zone electric heating (with heat isolation from LN2 cooling loop, or by using an external liquid thermostat with circulating heat-transfer agent. The principles of operation, design and test results of BBs are described.

  6. Study of spear as a dedicated source of synchrotron radiation

    Energy Technology Data Exchange (ETDEWEB)

    Cerino, J.; Golde, A.; Hastings, J.; Lindau, I.; Salsburg, B.; Winick, H.; Lee, M.; Morton, P.; Garren, A.

    1977-11-01

    A study was made of the potential of SPEAR as a dedicated source of synchrotron radiation, based on the expectation that SPEAR will become increasingly available for this purpose as PEP, the 18-GeV colliding-beam storage ring now under construction by LBL and SLAC, becomes operational. A synchrotron radiation research program has been underway since May, 1974. Two beam ports capable of serving 9 simultaneous users are now operational. In single-beam multi-bunch operation high currents are possible (225 mA has been achieved and > approximately 300 mA is expected) and the electron beam emittance can be made smaller, resulting in higher source point brightness. Descriptions are given of SPEAR capabilities and of plans to expand the research capability by adding beam runs and by inserting wiggler magnets in SPEAR straight sections.

  7. Study of SPEAR as dedicated source of synchrotron radiation

    Energy Technology Data Exchange (ETDEWEB)

    Cerino, J. (Stanford Univ., CA); Golde, A.; Hastings, J.; Lindau, I.; Salsburg, B.; Winick, H.; Lee, M.; Morton, P.; Garren, A.

    1977-06-01

    The potential of SPEAR as a dedicated source of synchrotron radiation was studied, based on the expectation that SPEAR will become increasingly available for this purpose as PEP, the 18-GeV colliding-beam storage ring now under construction by LBL and SLAC, becomes operational. A synchrotron radiation research program has been underway since May, 1974. Two beam ports capable of serving nine simultaneous users are now operational. In single-beam multi-bunch operation high currents are possible (225 mA has been achieved and greater than or approximately equal to 300 mA is expected) and the electron beam emittance can be made smaller, resulting in higher source point brightness. Descriptions are given of SPEAR capabilities and of plans to expand the research capability by adding beam runs and by inserting wiggler magnets in SPEAR straight sections.

  8. Simple formula for computing the Hubbell radiation rectangular source integral

    Energy Technology Data Exchange (ETDEWEB)

    Murley, Jonathan, E-mail: Jmurley@stu1.cs.upei.c [Department of Mathematics and Statistics, University of Prince Edward Island, Charlottetown, Prince Edward Island, C1A 4P3 (Canada); Saad, Nasser, E-mail: nsaad@upei.c [Department of Mathematics and Statistics, University of Prince Edward Island, Charlottetown, Prince Edward Island, C1A 4P3 (Canada)

    2011-01-15

    A simple analytic formula is derived for use in solving the Hubbell radiation rectangular source integrals H(a,b)={integral}{sub 0}{sup b}(x{sup 2}+1){sup -1/2}arctan(a(x{sup 2}+1){sup -1/2})dx,0

  9. Source levels and call parameters of harbor seal breeding vocalizations near a terrestrial haulout site in Glacier Bay National Park and Preserve.

    Science.gov (United States)

    Matthews, Leanna P; Parks, Susan E; Fournet, Michelle E H; Gabriele, Christine M; Womble, Jamie N; Klinck, Holger

    2017-03-01

    Source levels of harbor seal breeding vocalizations were estimated using a three-element planar hydrophone array near the Beardslee Islands in Glacier Bay National Park and Preserve, Alaska. The average source level for these calls was 144 dBRMS re 1 μPa at 1 m in the 40-500 Hz frequency band. Source level estimates ranged from 129 to 149 dBRMS re 1 μPa. Four call parameters, including minimum frequency, peak frequency, total duration, and pulse duration, were also measured. These measurements indicated that breeding vocalizations of harbor seals near the Beardslee Islands of Glacier Bay National Park are similar in duration (average total duration: 4.8 s, average pulse duration: 3.0 s) to previously reported values from other populations, but are 170-220 Hz lower in average minimum frequency (78 Hz).

  10. Fast radio burst source properties and curvature radiation model

    Science.gov (United States)

    Kumar, Pawan; Lu, Wenbin; Bhattacharya, Mukul

    2017-07-01

    We use the observed properties of fast radio bursts (FRBs) and a number of general physical considerations to provide a broad-brush model for the physical properties of FRB sources and the radiation mechanism. We show that the magnetic field in the source region should be at least 1014 G. This strong field is required to ensure that the electrons have sufficiently high ground state Landau energy so that particle collisions, instabilities and strong electromagnetic fields associated with the FRB radiation do not perturb electrons' motion in the direction transverse to the magnetic field and destroy their coherent motion; coherence is required by the high observed brightness temperature of FRB radiation. The electric field in the source region required to sustain particle motion for a wave period is estimated to be of the order of 1011 esu. These requirements suggest that FRBs are produced near the surface of magnetars perhaps via forced reconnection of magnetic fields to produce episodic, repeated, outbursts. The beaming-corrected energy release in these bursts is estimated to be about 1036 erg, whereas the total energy in the magnetic field is at least ˜1045 erg. We provide a number of predictions for this model which can be tested by future observations. One of which is that short duration FRB-like bursts should exist at much higher frequencies, possibly up to optical.

  11. Sulfate Aerosol in the Arctic: Source Attribution and Radiative Forcing

    Energy Technology Data Exchange (ETDEWEB)

    Yang, Yang [Atmospheric Science and Global Change Division, Pacific Northwest National Laboratory, Richland WA USA; Wang, Hailong [Atmospheric Science and Global Change Division, Pacific Northwest National Laboratory, Richland WA USA; Smith, Steven J. [Joint Global Change Research Institute, Pacific Northwest National Laboratory, College Park MD USA; Easter, Richard C. [Atmospheric Science and Global Change Division, Pacific Northwest National Laboratory, Richland WA USA; Rasch, Philip J. [Atmospheric Science and Global Change Division, Pacific Northwest National Laboratory, Richland WA USA

    2018-02-08

    Source attributions of Arctic sulfate and its direct radiative effect for 2010–2014 are quantified in this study using the Community Earth System Model (CESM) equipped with an explicit sulfur source-tagging technique. Regions that have high emissions and/or are near/within the Arctic present relatively large contributions to Arctic sulfate burden, with the largest contribution from sources in East Asia (27%). East Asia and South Asia together have the largest contributions to Arctic sulfate concentrations at 9–12 km, whereas sources within or near the Arctic account largely below 2 km. For remote sources with strong emissions, their contributions to Arctic sulfate burden are primarily driven by meteorology, while contributions of sources within or near the Arctic are dominated by their emission strength. The sulfate direct radiative effect (DRE) is –0.080 W m-2 at the Arctic surface, offsetting the net warming effect from the combination of in-snow heating and DRE cooling from black carbon. East Asia, Arctic local and Russia/Belarus/Ukraine sources contribute –0.017, –0.016 and –0.014 W m-2, respectively, to Arctic sulfate DRE. A 20% reduction in anthropogenic SO2 emissions leads to a net increase of +0.013 W m-2 forcing at the Arctic surface. These results indicate that a joint reduction in BC emissions could prevent possible Arctic warming from future reductions in SO2 emissions. Sulfate DRE efficiency calculations suggest that short transport pathways together with meteorology favoring long sulfate lifetimes make certain sources more efficient in influencing the Arctic sulfate DRE.

  12. Safety Assessment Of The Centralized Storage Facility For Disused Sealed Radioactive Sources In United Republic Of Tanzania

    Energy Technology Data Exchange (ETDEWEB)

    Abel, Vitus [Korea Advanced Institute of Science and Technology, Daejeon (Korea, Republic of); Lee, JaeSeong [Korea Institute of Nuclear Safety, Daejeon (Korea, Republic of)

    2014-10-15

    SRS are no longer in use, they are declared as disused, and they are transferred to the central radioactive management facility (CRMF) belonging to Tanzania Atomic Energy Commission (regulatory body) and managed as radioactive waste. In order to reduce the risk associated with disused sealed radioactive sources (DSRS), the first priority would be to bring them to appropriate controls under the regulatory body. When DSRS are safely managed, regulatory body need to make assessment of the likelihood and potential impact of incidents, accidents and hazards for proper management plan. The paper applies Analytical Hierarchy Process (AHP) for assessing and allocating weights and priorities for solving the problem of mult criteria consideration for management plan. Using pairwise comparisons, the relative importance of one criterion over another can be expressed. The method allows decision makers to provide judgments about the relative importance of each criterion and to estimate radiological risk by using expert's judgments or probability of occurrence. AHP is the step by step manner where the resulting priorities are shown and the possible inconsistencies are determined. The Information provided by experts helps to rank hazards according to probability of occurrence, potential impact and mitigation cost. The strength of the AHP method lies in its ability to incorporate both qualitative and quantitative data in decision making. AHP present a powerful tool for weighting and prioritizing hazards in terms of occurrence probability. However, AHP also has some weak points. AHP requires data based on experience, knowledge and judgment which are subjective for each decision-maker.

  13. An oil-free compact X-pinch plasma radiation source: Design and radiation performance.

    Science.gov (United States)

    Shapovalov, Roman V; Spielman, Rick B; Imel, George R

    2017-06-01

    This paper describes a new, high-current, X-pinch radiation source recently developed and tested at Idaho State University. Our design is based on two linear transformer driver (LTD) bricks arranged in side-by-side geometry and directly coupled with an X-pinch load. The salient features of our 2-LTD-bricks are its simplicity, compactness, and portability: there is no oil, no water, and no SF 6 . It can be easily relocated to any place where a compact X-pinch radiation source is wanted. The driver can store up to 2.8 kJ of initial energy and can deliver more than 200-kA peak-current with less than 200-ns, 10%-90%, rise time into a short-circuit load. When the driver is coupled with an X-pinch load, it generates a very fast and bright radiation pulse. Source size measurements indicate that this radiation originates from a very small dense plasma, known as a "hot spot."

  14. Health risk assessment of jobs involving ionizing radiation sources

    Directory of Open Access Journals (Sweden)

    Spasojević-Tišma Vera D.

    2011-01-01

    Full Text Available The study included 75 subjects exposed to low doses of external ionizing radiation and 25 subjects from the control group, all male. The first group (A consisted of 25 subjects employed in the production of technetium, with an average job experience of 15 years. The second group (B consisted of 25 subjects exposed to ionizing radiation from enclosed sources, working in jobs involving the control of X-ray devices and americium smoke detectors, their average work experience being 18.5 years. The third group (C consisted of 25 subjects involved in the decontamination of the terrain at Borovac from radioactive rounds with depleted uranium left over after the NATO bombing of Serbia in 1999, their average job experience being 18.5 years. The control group (K consisted of 25 subjects who have not been in contact with sources of ionizing radiation and who hold administrative positions. Frequencies of chromosome aberrations were determined in lymphocytes of peripheral blood and compared to the control group. The average annual absorbed dose determined by thermoluminescent dosimeters for all three groups did not exceed 2 mSv. In the present study, the largest number of observed changes are acentric fragments and chromosome breaks. The highest occupational risk appears to involve subjects working in manufacturing of the radio-isotope technetium.

  15. Gulf and Dilmun Type seals

    DEFF Research Database (Denmark)

    Laursen, Steffen

    2011-01-01

    From around 2100 BC a glyptic tradition emerges in the Arabian Gulf, which is dependant on the well-established schools of the Indus Valley seal cutters. These circular hybrids of classic Harappan seals rapidly became popular amongst the merchants of Dilmun, centered on Bahrain Island. At first...... these Gulf Type‘ seals drew heavily on Indus Valley iconography and Indus script was occasionally employed in a pidgin-like manner. While the earliest circular seals incorporate features from Mesopotamian glyptic only to a lesser extent, this becomes a more important source of inspiration for later Dilmun...... Type seals....

  16. An inverse source location algorithm for radiation portal monitor applications

    Energy Technology Data Exchange (ETDEWEB)

    Miller, Karen A [Los Alamos National Laboratory; Charlton, William S [Los Alamos National Laboratory

    2010-01-01

    Radiation portal monitors are being deployed at border crossings throughout the world to prevent the smuggling of nuclear and radiological materials; however, a tension exists between security and the free-flow of commerce. Delays at ports-of-entry have major economic implications, so it is imperative to minimize portal monitor screening time. We have developed an algorithm to locate a radioactive source using a distributed array of detectors, specifically for use at border crossings. To locate the source, we formulated an optimization problem where the objective function describes the least-squares difference between the actual and predicted detector measurements. The predicted measurements are calculated by solving the 3-D deterministic neutron transport equation given an estimated source position. The source position is updated using the steepest descent method, where the gradient of the objective function with respect to the source position is calculated using adjoint transport calculations. If the objective function is smaller than the convergence criterion, then the source position has been identified. This paper presents the derivation of the underlying equations in the algorithm as well as several computational test cases used to characterize its accuracy.

  17. Radiation damage of the ILC positron source target

    Energy Technology Data Exchange (ETDEWEB)

    Ushakov, A.; Riemann, S.

    2007-11-15

    The radiation damage of the positron source target for the International Linear Collider (ILC) has been studied. The displacement damage in target material due to multi-MeV photons has been calculated by combining FLUKA simulations for secondary particle production, SPECTER data for neutron displacement cross-sections and the Lindhard model for estimations of displacement damage by ions. The radiation damage of a stationary Ti6Al4V target in units of displacements per atom (dpa) has been estimated for photons from an undulator with strength 0.92 and period 1.15 cm. The calculated damage is 7 dpa. Approximately 12.5% of displacement damage result from neutrons. (orig.)

  18. 76 FR 76327 - Installation of Radiation Alarms for Rooms Housing Neutron Sources

    Science.gov (United States)

    2011-12-07

    ... COMMISSION 10 CFR Part 73 Installation of Radiation Alarms for Rooms Housing Neutron Sources AGENCY: Nuclear... radiation alarms in rooms housing neutron sources. DATES: Submit comments by February 21, 2012. Comments..., Radiation Safety for Research. Mr. Hamawy is concerned about the security of neutron sources. III. Petition...

  19. Laser sources in dentistry and radiation safety regulations

    Science.gov (United States)

    De Luca, D.; Gaeta, G. M.; Lepore, M.

    2007-02-01

    Nowadays laser sources are largely adopted in dentistry due to their unique properties making them good candidates to substitute traditional scalpel and conventional diamond bur in the surgery of the soft and hard oral tissue, respectively. The large use of laser sources outside the research laboratories without the need of highly specialized personnel can ask for a widespread knowledge of safety issues related to this kind of equipment. The main hazard of accidental exposures regards eyes injury but increasing the power of the laser beam also skin can be involved. Safety legislations in Europe and U.S.A. take into account non ionizing radiations and laser radiation for the hazards for the health deriving from physical agents. Laser safety standards introduce 3 useful parameters for hazard characterization: "Accessible Emission Limit" (AEL), "Maximum Permissible Exposure" (MPE) and "Nominal Ocular Hazard Distance" (NOHD). We measured the MPE and NOHD for Er:YAG and other laser sources currently adopted in dentistry and we compared our results with data elaborated from standards in order to single out safe and comfortable working conditions. In fact an experimental assessment of the hazard parameters and the comparison with those of reference from safety standards turns out to be useful in order to estimate the residual hazard that can be still present after applying all the engineering protection and administrative rules.

  20. Measurement of parameters in Indus-2 synchrotron radiation source.

    Science.gov (United States)

    Ghodke, A D; Husain, Riyasat; Kumar, Pradeep; Yadav, Surendra; Puntambekar, T A

    2012-10-01

    The paper presents the measurement of optics parameters in Indus-2 synchrotron radiation source, which include betatron tune, beta function, dispersion function, natural chromaticity, corrected chromaticity, central RF frequency, momentum compaction factor, and linear betatron coupling. Two methods were used for beta function measurement; a conventional quadrupole scan method and a method using the fitting of the orbit response matrix. A robust Levenberg-Marquardt algorithm was used for nonlinear least square fitting of the orbit response matrix. In this paper, detailed methods for the parameter measurements are described. The measured results are discussed and compared with the theoretical values obtained using accelerator simulation code Accelerator Toolbox in MATLAB.

  1. Chemical plating method of preparing radiation source material

    Science.gov (United States)

    Smith, P.K.; Huntoon, R.T.; Mosley, W.C. Jr.

    1973-12-11

    A uniform dispersion of a radioisotope within a noble metal matrix is provided by chemically plating a noble metal coating onto particles including a dissociable compound of the mdioisotope. A suspension of the dissociable compound in a chemically reductive solution is prepared and noble metal cations added to produce the noble metal coatings. The coated particles are filtered, dried and heated to calcine the dissociable compound to a refractory powder. The powder can be encapsulated in measured portions or consolidated and shaped into an elongated form for easy apportionnnent as radiation source material. (Official Gazette)

  2. AREAL test facility for advanced accelerator and radiation source concepts

    Science.gov (United States)

    Tsakanov, V. M.; Amatuni, G. A.; Amirkhanyan, Z. G.; Aslyan, L. V.; Avagyan, V. Sh.; Danielyan, V. A.; Davtyan, H. D.; Dekhtiarov, V. S.; Gevorgyan, K. L.; Ghazaryan, N. G.; Grigoryan, B. A.; Grigoryan, A. H.; Hakobyan, L. S.; Haroutiunian, S. G.; Ivanyan, M. I.; Khachatryan, V. G.; Laziev, E. M.; Manukyan, P. S.; Margaryan, I. N.; Markosyan, T. M.; Martirosyan, N. V.; Mehrabyan, Sh. A.; Mkrtchyan, T. H.; Muradyan, L. Kh.; Nikogosyan, G. H.; Petrosyan, V. H.; Sahakyan, V. V.; Sargsyan, A. A.; Simonyan, A. S.; Toneyan, H. A.; Tsakanian, A. V.; Vardanyan, T. L.; Vardanyan, A. S.; Yeremyan, A. S.; Zakaryan, S. V.; Zanyan, G. S.

    2016-09-01

    Advanced Research Electron Accelerator Laboratory (AREAL) is a 50 MeV electron linear accelerator project with a laser driven RF gun being constructed at the CANDLE Synchrotron Research Institute. In addition to applications in life and materials sciences, the project aims as a test facility for advanced accelerator and radiation source concepts. In this paper, the AREAL RF photoinjector performance, the facility design considerations and its highlights in the fields of free electron laser, the study of new high frequency accelerating structures, the beam microbunching and wakefield acceleration concepts are presented.

  3. Methods of computer experiment in gamma-radiation technologies using new radiation sources

    CERN Document Server

    Bratchenko, M I; Rozhkov, V V

    2001-01-01

    Presented id the methodology of computer modeling application for physical substantiation of new irradiation technologies and irradiators design work flow. Modeling tasks for irradiation technologies are structured along with computerized methods of their solution and appropriate types of software. Comparative analysis of available packages for Monte-Carlo modeling of electromagnetic processes in media is done concerning their application to irradiation technologies problems. The results of codes approbation and preliminary data on gamma-radiation absorbed dose distributions for nuclides of conventional sources and prospective Europium-based gamma-sources are presented.

  4. Source tilting within the difference formulation for radiation transport

    Energy Technology Data Exchange (ETDEWEB)

    Luu, T; Brooks, E; Szoke, A

    2006-09-27

    We apply a heuristic technique known as 'source tilting' to a Monte Carlo solution for radiation transport, in the difference formulation, that otherwise employs a piecewise-constant treatment of the material temperature. Source tilting improves the accuracy of the piecewise-constant treatment, reducing the excessive energy flow that occurs in the thick limit. An analysis of the cause of excessive energy flow suggests an interpolation scheme that removes this defect, obtaining the correct diffusion limit flux between zones. The results obtained with our interpolation scheme agree almost identically to those of a self-consistent piecewise-linear treatment of the difference formulation while avoiding its additional costs. The resulting method is capable of providing robust and accurate calculations for problems involving optically thick zones. We comment on the monotonicity issues that arise when employing this transport method.

  5. Explosive pulsed power system for new radiation sources.

    Energy Technology Data Exchange (ETDEWEB)

    Oona, H. (Henn); Goforth, J. H. (James H.); Idzorek, G. C. (George C.); Herrera, D. H. (Dennis H.); King, J. C. (James Carrel); Lopez, E. A. (Emmanuel A.); Tasker, D. G. (Douglas G.); Torres, D. T. (David T)

    2004-01-01

    High explosive pulsed power (HEPP) systems are capable of accessing very high energy densities and can reach conditions that are not possible with capacitor bank systems. The Procyon system was developed and used for experiments over a period of six years, and is exemplary of the capabilities of HEPP systems for state-of-the-art research. In this paper we will summarize some of the more interesting aspects of the work done in the past but will suggest ideas toward applications for future research. One of the main, unique features of HEPP systems is that they integrate easily to a particular physics experiment and the power flow can be optimized for a specific test. Magnetic flux compression generators have been an ideal power source for both high current plasma physics and hydrodynamic experimental loads. These experiments have contributed greatly to the understanding of high temperature and density plasmas and more recently to the understanding of instability growth in thick ({approx}1 mm) imploding metal cylinders. Common to all these experiments is the application of a large current pulse to a cylindrically symmetric load. The resulting Lorenz force compresses the load to produce hydrodynamic motion and/or high temperature, high density plasma. In the plasma physics experiments, plasma thermalizes on axis and a black body distribution of x-rays is produced. To get better access to the radiation pulse, the load electrode geometry was modified. For example, by shaping the plasma implosion glide planes, a mass depletion region was formed along one electrode at pinch time which generated a very large voltage drop across a 1-2 mm segment of the pinch, and also produced a high energy ion beam on axis. These results were predicted by magneto-hydro-dynamic (MHD) codes and verified with framing camera and x-ray, pinhole, camera pictures. We have not previously published these features but will take another look and propose possible scenarios for studying and generating

  6. SU-C-16A-06: Optimum Radiation Source for Radiation Therapy of Skin Cancer

    Energy Technology Data Exchange (ETDEWEB)

    Safigholi, Habib [Science and Research Branch, Islamic Azad University, Fars, Persepolis (Iran, Islamic Republic of); Meigooni, A S. [Comprehensive cancer center of Nevada, Las Vegas, NV (United States); University of Nevada Las Vegas (UNLV), Las Vegas, NV (United States)

    2014-06-15

    Purpose: Recently, different applicators are designed for treatment of the skin cancer such as scalp and legs, using Ir-192 HDR Brachytherapy Sources (IR-HDRS), Miniature Electronic Brachytherapy Sources (MEBXS), and External Electron Beam Radiation Therapy (EEBRT). Although, all of these methodologies may deliver the desired radiation dose to the skin, the dose to the underlying bone may become the limiting factor for selection of the optimum treatment technique. In this project the radiation dose delivered to the underlying bone has been evaluated as a function of the radiation source and thickness of the underlying bone. Methods: MC simulations were performed using MCNP5 code. In these simulations, the mono-energetic and non-divergent photon beams of 30 keV, 50 keV, and 70 keV for MEBXS, 380 keV photons for IR-HDRS, and 6 MeV mono-energetic electron beam for EEBRT were modeled. A 0.5 cm thick soft tissue (0.3 cm skin and 0.2 cm adipose) with underlying 0.5 cm cortical bone followed by 14 cm soft tissue are utilized for simulations. Results: Dose values to bone tissue as a function of beam energy and beam type, for a delivery of 5000 cGy dose to skin, were compared. These results indicate that for delivery of 5000 cGy dose to the skin surface with 30 keV, 50 keV, 70 keV of MEBXS, IR-HDRS, and EEBRT techniques, bone will receive 31750 cGy, 27450 cGy, 18550 cGy, 4875 cGy, and 10450 cGy, respectively. Conclusion: The results of these investigations indicate that, for delivery of the same skin dose, average doses received by the underlying bone are 5.2 and 2.2 times larger with a 50 keV MEBXS and EEBRT techniques than IR-HDRS, respectively.

  7. The Advanced Light Source: A third-generation Synchrotron Radiation Source

    Energy Technology Data Exchange (ETDEWEB)

    Robinson, Arthur L.

    2002-08-14

    The Advanced Light Source (ALS) at the E.O. Lawrence Berkeley National Laboratory (Berkeley Lab) of the University of California is a ''third-generation'' synchrotron radiation source optimized for highest brightness at ultraviolet and soft x-ray photon energies. It also provides world-class performance at hard x-ray photon energies. Berkeley Lab operates the ALS for the United States Department of Energy as a national user facility that is available 24 hours/day around the year for research by scientists from industrial, academic, and government laboratories primarily from the United States but also from abroad.

  8. Ferrules seals

    Science.gov (United States)

    Smith, J.L.

    1984-07-10

    A device is provided for sealing an inner tube and an outer tube without excessively deforming the tubes. The device includes two ferrules which cooperate to form a vacuum-tight seal between the inner tube and outer tube and having mating surfaces such that overtightening is not possible. 3 figs.

  9. Ceramic Seal.

    Energy Technology Data Exchange (ETDEWEB)

    Smartt, Heidi A. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Romero, Juan A. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Custer, Joyce Olsen [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Hymel, Ross W. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Krementz, Dan [Savannah River Site (SRS), Aiken, SC (United States). Savannah River National Lab. (SRNL); Gobin, Derek [Savannah River Site (SRS), Aiken, SC (United States). Savannah River National Lab. (SRNL); Harpring, Larry [Savannah River Site (SRS), Aiken, SC (United States). Savannah River National Lab. (SRNL); Martinez-Rodriguez, Michael [Savannah River Site (SRS), Aiken, SC (United States). Savannah River National Lab. (SRNL); Varble, Don [Savannah River Site (SRS), Aiken, SC (United States). Savannah River National Lab. (SRNL); DiMaio, Jeff [Tetramer Technologies, Pendleton, SC (United States); Hudson, Stephen [Tetramer Technologies, Pendleton, SC (United States)

    2016-11-01

    Containment/Surveillance (C/S) measures are critical to any verification regime in order to maintain Continuity of Knowledge (CoK). The Ceramic Seal project is research into the next generation technologies to advance C/S, in particular improving security and efficiency. The Ceramic Seal is a small form factor loop seal with improved tamper-indication including a frangible seal body, tamper planes, external coatings, and electronic monitoring of the seal body integrity. It improves efficiency through a self-securing wire and in-situ verification with a handheld reader. Sandia National Laboratories (SNL) and Savannah River National Laboratory (SRNL), under sponsorship from the U.S. National Nuclear Security Administration (NNSA) Office of Defense Nuclear Nonproliferation Research and Development (DNN R&D), have previously designed and have now fabricated and tested Ceramic Seals. Tests have occurred at both SNL and SRNL, with different types of tests occurring at each facility. This interim report will describe the Ceramic Seal prototype, the design and development of a handheld standalone reader and an interface to a data acquisition system, fabrication of the seals, and results of initial testing.

  10. Flux and brightness calculations for various synchrotron radiation sources

    Energy Technology Data Exchange (ETDEWEB)

    Weber, J.M.; Hulbert, S.L.

    1991-11-01

    Synchrotron radiation (SR) storage rings are powerful scientific and technological tools. The first generation of storage rings in the US., e.g., SURF (Washington, D.C.), Tantalus (Wisconsin), SSRL (Stanford), and CHESS (Cornell), revolutionized VUV, soft X-ray, and hard X-ray science. The second (present) generation of storage rings, e.g. the NSLS VUV and XRAY rings and Aladdin (Wisconsin), have sustained the revolution by providing higher stored currents and up to a factor of ten smaller electron beam sizes than the first generation sources. This has made possible a large number of experiments that could not performed using first generation sources. In addition, the NSLS XRAY ring design optimizes the performance of wigglers (high field periodic magnetic insertion devices). The third generation storage rings, e.g. ALS (Berkeley) and APS (Argonne), are being designed to optimize the performance of undulators (low field periodic magnetic insertion devices). These extremely high brightness sources will further revolutionize x-ray science by providing diffraction-limited x-ray beams. The output of undulators and wigglers is distinct from that of bending magnets in magnitude, spectral shape, and in spatial and angular size. Using published equations, we have developed computer programs to calculate the flux, central intensity, and brightness output bending magnets and selected wigglers and undulators of the NSLS VUV and XRAY rings, the Advanced Light Source (ALS), and the Advanced Photon Source (APS). Following is a summary of the equations used, the graphs and data produced, and the computer codes written. These codes, written in the C programming language, can be used to calculate the flux, central intensity, and brightness curves for bending magnets and insertion devices on any storage ring.

  11. Personnel dose assessment due to the normal operations with the artificial radiation sources according to the data from the unified system of individual dose control (USIDC

    Directory of Open Access Journals (Sweden)

    Yu. I. Stepkin

    2016-01-01

    Full Text Available The aim of the study was personnel dose assessment due to the normal operations with the artificial radiation sources. The article is based on the data from the Unified System of Individual Dose Control and Voronezh Region’s radiation-hygienic passport. The data from No.1-DOZ “Information on personnel exposure doses under normal operation of technogenic ionizing radiation sources” and over a period of 2006-2010 years were analyzed. In 2006-2015, the number of organizations, which submitted form No.1-DOZ “Information on personnel exposure doses under normal operation of technogenic ionizing radiation sources”, increased from 175 to 229. In amount of the radiation facilities, Novovoronezh Nuclear Power Plant is the first. Novovoronezh NPP has 1512 sources, which amounts to 51,9% from all sources in Voronezh Region (2915. Health care facilities have 869 radiation sources or 29,8%. X-ray machines are the main part of these sources (844 health care facilities or 97,1% of all medical sources. Industrial sources occupy third place with 305 facilities or 10,5% of all considered sources. In 2015, according to the data from Voronezh Region’s radiation-hygienic passport, the number of “A” group personnel were 4237, the number of “B” group personnel were 2341. The average individual dose for personnel was over the range from 0.66 to 2.02 mSv. Collective dose was from 4.16 to 11.79 man-sieverts per year. The increase of number of the radiation sources has attended with the decrease of individual and collective doses. The most likely it is related to using the modern facilities. In 2015, the maximum value of the average individual dose of “A” group personnel was registered in Voronezh regional hospital (6.17 mSv y–1. There are medical facilities with unsealed and sealed sources in this hospital. In 2006-2015, the average individual doses of personnel of all radiation facilities that use radiation sources in Voronezh

  12. Chorus Emission Source Spatial Scales in the Terrestrial Radiation Belts

    Science.gov (United States)

    Agapitov, O. V.; Mozer, F.; Blum, L. W.; Wygant, J. R.; Bonnell, J. W.; Shastun, V.

    2016-12-01

    The key parameters for either non-linear wave particle interactions or for the quasi-linear approach are the temporal and spatial scales of the wave source region and coherence of the oscillations in a wave package. Both of these scales (the source scale and the coherence scale) are not well-established experimentally. We investigated both of these scales using coordinated multi-point measurements from the THEMIS and Van Allen Probes missions. To accomplish these objectives, we collected long intervals of six components VLF wave measurements (16384 s-1) aboard the Van Allen Probes in the outer radiation belt during close lapping events. The spatial scales of the chorus wave source region have been found to be around 400-600 km in transverse to the background magnetic field direction for L-shells from 4 to 6. The coherence spatial and temporal scales for chorus has been found to be less/about 100 km. The results obtained from the high resolution waveform analysis have been confirmed by the THEMIS continuous measurements (FBK and FFT)

  13. Radiation protection and safety of radiation sources international basic safety standards

    CERN Document Server

    International Atomic Energy Agency. Vienna

    2014-01-01

    The Board of Governors of the IAEA first approved Basic Safety Standards in June 1962; they were published by the IAEA as IAEA Safety Series No. 9. A revised edition was issued in 1967. A third revision was published by the IAEA as the 1982 Edition of IAEA Safety Series No. 9 ; this edition was jointly sponsored by the IAEA, ILO, OECD/NEA and the WHO. The next edition was International Basic Safety Standards for Protection against Ionizing Radiation and for the Safety of Radiation Sources, published by the IAEA as IAEA Safety Series No. 115 in February 1996, and jointly sponsored by the FAO, IAEA, ILO, OECD/NEA, PAHO and the WHO.

  14. Calculations for Tera-Hertz (THZ) Radiation Sources

    CERN Document Server

    Spencer, James

    2005-01-01

    We explore possibilities for THz sources from 0.3 - 30 THz. While still inaccessible, this broad gap is even wider for advanced acceleration schemes extending from X or, at most, W band RF at the low end up to CO2 lasers. While the physical implementations of these two approaches are quite different, both are proving difficult to develop so that even lower frequency, superconducting RF seems to be the currently preferred means. Similarly, the validity of modelling techniques varies greatly over this range of frequencies but generally mandates coupling Maxwell’s equations to the appropriate device transport physics for which there are many options. Here we calculate radiation from shaped transmission lines using finite-difference, time-domain (FDTD) simulations of Maxwell’s equations coupled to Monte-Carlo techniques for both the production and transport physics of short electron pulses. Examples of THz sources that demonstrate coherent interference effects will be discussed with the goal o...

  15. Seal Counts

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Database of seal counts from aerial photography. Counts by image, site, species, and date are stored in the database along with information on entanglements and...

  16. LIGHT SOURCE: Design of a new compact THz source based on Smith-Purcell radiation

    Science.gov (United States)

    Dai, Dong-Dong; Bei, Hua; Dai, Zhi-Min

    2009-06-01

    In recent years, people are dedicated to the research work of finding compact THz sources with high emission power. Smith-Purcell radiation is qualified for the possibility of coherent enhancement due to the effect of FEL mechanism. The compact experiment device is expected to produce hundreds mW level THz ray. The electron beam with good quality is provided under the optimized design of the electron gun. Besides, the grating is designed as an oscillator without any external feedbacks. While the beam passes through the grating surface, the beam bunching will be strong and the second harmonics enhancement will be evident, as is seen from the simulation results.

  17. [Christmas seals].

    Science.gov (United States)

    Loytved, G

    2006-11-01

    Christmas seals, i. e., special stamps used to decorate or seal Christmas and New Year's mail, were created by the Danish post office clerk E. Holboell. The proceeds from the sale of the stickers were meant to alleviate the suffering of children sick with tuberculosis. The first Christmas seal, showing a portrait of Queen Louise of Denmark, was issued on December 10, 1904. The demand at the post office was enormous. The funds raised exceeded all expectations and made it possible to finance the construction of a sanatorium for tuberculosis children. The idea of Christmas seals spread quickly around the world and ended up being copied in 130 countries. At the beginning of the 20 (th) century, the small stamp with the red double-barred cross became a banner for the crusade against tuberculosis. For many patients, it also represented a symbol of hope for recovery even though this hope, given the cure rates of a sanatorium treatment, only became a reality for a few. Worldwide, Christmas seals were and are colourful and imaginatively designed, mostly with Christmas symbols or motives relating to the fight against tuberculosis. The funds raised through the sale of the seals initially helped to build hospitals and were later also used to screen persons at risk for tuberculosis, to improve housing conditions of patients and for other measures of support. With the decrease of tuberculosis, some organisations discontinued fundraising through Christmas seals while others widened their intended purpose and supported, for example, the prevention of and research on lung diseases. In Germany, Christmas seals are closely connected with the German Central Committee against Tuberculosis. Today the "Kuratorium Tuberkulose in der Welt" is the only organisation in this country that still raises funds by this means. The funds are mostly used to assist developing countries with a high burden of tuberculosis.

  18. Radiation resistant erbium doped fiber for ASE source and fiber gyroscope application

    Science.gov (United States)

    Pinsard, Emmanuel; Laurent, Arnaud; Robin, Thierry; Cadier, Benoît; Ferrand, Sébastien; Bonnefois, Jean-Jacques; Moluçon, Cedric; Boutillier, Mathieu

    2017-11-01

    A radiation resistant optical fiber used in a broadband source is presented. Both ASE source and Fiber Optical Gyroscope (FOG) commonly used in space missions, suffer from failures and degradation after long term exposure to radiative environment. The aim of this article is to present the results of our investigation on fiber and ASE source architecture in order to design a Radiation Resistant Erbium Doped Fiber that offers long term stability of the gyroscope performances.

  19. HELIOS: A new open-source radiative transfer code

    Science.gov (United States)

    Malik, Matej; Grosheintz, Luc; Lukas Grimm, Simon; Mendonça, João; Kitzmann, Daniel; Heng, Kevin

    2015-12-01

    I present the new open-source code HELIOS, developed to accurately describe radiative transfer in a wide variety of irradiated atmospheres. We employ a one-dimensional multi-wavelength two-stream approach with scattering. Written in Cuda C++, HELIOS uses the GPU’s potential of massive parallelization and is able to compute the TP-profile of an atmosphere in radiative equilibrium and the subsequent emission spectrum in a few minutes on a single computer (for 60 layers and 1000 wavelength bins).The required molecular opacities are obtained with the recently published code HELIOS-K [1], which calculates the line shapes from an input line list and resamples the numerous line-by-line data into a manageable k-distribution format. Based on simple equilibrium chemistry theory [2] we combine the k-distribution functions of the molecules H2O, CO2, CO & CH4 to generate a k-table, which we then employ in HELIOS.I present our results of the following: (i) Various numerical tests, e.g. isothermal vs. non-isothermal treatment of layers. (ii) Comparison of iteratively determined TP-profiles with their analytical parametric prescriptions [3] and of the corresponding spectra. (iii) Benchmarks of TP-profiles & spectra for various elemental abundances. (iv) Benchmarks of averaged TP-profiles & spectra for the exoplanets GJ1214b, HD189733b & HD209458b. (v) Comparison with secondary eclipse data for HD189733b, XO-1b & Corot-2b.HELIOS is being developed, together with the dynamical core THOR and the chemistry solver VULCAN, in the group of Kevin Heng at the University of Bern as part of the Exoclimes Simulation Platform (ESP) [4], which is an open-source project aimed to provide community tools to model exoplanetary atmospheres.-----------------------------[1] Grimm & Heng 2015, ArXiv, 1503.03806[2] Heng, Lyons & Tsai, Arxiv, 1506.05501Heng & Lyons, ArXiv, 1507.01944[3] e.g. Heng, Mendonca & Lee, 2014, ApJS, 215, 4H[4] exoclime.net

  20. Novel particle and radiation sources and advanced materials

    Energy Technology Data Exchange (ETDEWEB)

    Mako, Frederick [FM Technologies, Inc. and Electron Technologies, Inc. (United States)

    2016-03-25

    The influence Norman Rostoker had on the lives of those who had the pleasure of knowing him is profound. The skills and knowledge I gained as a graduate student researching collective ion acceleration has fueled a career that has evolved from particle beam physics to include particle and radiation source development and advanced materials research, among many other exciting projects. The graduate research performed on collective ion acceleration was extended by others to form the backbone for laser driven plasma ion acceleration. Several years after graduate school I formed FM Technologies, Inc., (FMT), and later Electron Technologies, Inc. (ETI). Currently, as the founder and president of both FMT and ETI, the Rostoker influence can still be felt. One technology that we developed is a self-bunching RF fed electron gun, called the Micro-Pulse Gun (MPG). The MPG has important applications for RF accelerators and microwave tube technology, specifically clinically improved medical linacs and “green” klystrons. In addition to electron beam and RF source research, knowledge of materials and material interactions gained indirectly in graduate school has blossomed into breakthroughs in materials joining technologies. Most recently, silicon carbide joining technology has been developed that gives robust helium leak tight, high temperature and high strength joints between ceramic-to-ceramic and ceramic-to-metal. This joining technology has the potential to revolutionize the ethylene production, nuclear fuel and solar receiver industries by finally allowing for the practical use of silicon carbide as furnace coils, fuel rods and solar receptors, respectively, which are applications that have been needed for decades.

  1. Crystal undulator as a new compact source of radiation

    Directory of Open Access Journals (Sweden)

    S. Bellucci

    2004-02-01

    Full Text Available Crystalline undulators with periodically deformed crystallographic planes offer coherent electromagnetic fields on the order of 1000 T and provide undulator period L in submillimeter range. We present an idea for creation of a crystalline undulator and report its realization. One face of a silicon crystal was given periodic microscratches (grooves by means of a diamond blade, with a period ranging from 0.1 to 0.5 mm in different samples. The x-ray tests of the crystal deformation have shown that a sinusoidal-like shape of crystalline planes goes through the bulk of the crystals. This opens up the possibility for experiments with high-energy particles channeled in the crystalline undulator, a new compact source of radiation. The first experiments on photon emission in the crystal undulator are in preparation at IHEP (Protvino with 2–15 GeV positrons and at LNF (Frascati with 500–800 MeV positrons, aiming to produce undulator photons in the range of 50–500 keV. The results of Monte Carlo simulations for the planned experiments are presented as well.

  2. Radiation protection for the illegal governmental use of radiation sources. A case study

    Energy Technology Data Exchange (ETDEWEB)

    Becker, K.

    2000-07-01

    Probably for the first time, illegal governmental uses of radiation sources, including the administrative infrastructure such as special radiation protection regulation, an advisory body etc., have been documented by the evaluation of the documents of the Ministry of State Security in the former German Democratic Republic (East Germany). Over a thousand persons, but also documents, money bills etc. were marked with a wide variety of radionuclides and traced with specially developed detectors. Among the many different nuclides provided regularly from the Rossendorf Research Center near Dresden, in particular {sup 46}Sc was popular. (orig.) [German] 'Regierungskriminalitaet' kann man auch im deutschen Strahlenschutz finden. Anhand neuer Dokumentationen der so genannten Gauckbehoerden, ueber die auch schon fluechtig in der Presse berichtet und spekuliert wurde, lassen sich Einzelheiten ueber die Vorgehensweisen einfallsreicher Stasi-Mitarbeiter, die Stasi-eigene Strahlenschutzverordnung und Strahlenschutz-Kommission usw. rekonstruieren. Ueber 1.000 Personen, aber auch Gegenstaende, Dokumente, Geldscheine etc. wurden markiert, wobei unter einer Vielzahl der regelmaessig aus Rossendorf gelieferten Nukliden {sup 46}Sc besonders gern eingesetzt sowie in Dresden spezielle Nachweisgeraete entwickelt wurden. (orig.)

  3. A new source of radiation in single-bubble sonoluminescence

    Indian Academy of Sciences (India)

    2017-03-28

    Mar 28, 2017 ... In this article, by considering single-bubble sonoluminescence and based on the hydrochemical model and thermal bremsstrahlung approach, for the first time two different origins of light have numerically been studied to describe the Ar bubble radiation in water at the moment of collapse: (a) radiation.

  4. A new source of radiation in single-bubble sonoluminescence

    Indian Academy of Sciences (India)

    In this article, by considering single-bubble sonoluminescence and based on the hydrochemical model and thermal bremsstrahlung approach, for the first time two different origins of light havenumerically been studied to describe the Ar bubble radiation in water at the moment of collapse: (a) radiation from the Ar gas inside ...

  5. Sources management; La gestion des sources

    Energy Technology Data Exchange (ETDEWEB)

    Mansoux, H.; Gourmelon; Scanff, P.; Fournet, F. [Institut de Radioprotection et de Surete Nucleaire, 92 - Fontenay-aux-Roses (France); Murith, Ch. [Office Federal de la SantePublique (Switzerland); Saint-Paul, N. [NOVAR, 75 - Paris (France); Colson, P. [Electricite de France (EDF/DPN), 93 - Saint-Denis (France); Jouve, A.; Feron, F. [Direction Generale de al Surete Nucleaire et de la Radioprotection, 75 - Paris (France); Haranger, D. [Electricite de France (EDF), 75 - Paris (France); Mathieu, P. [Institut Pasteur, 75 - Paris (France); Paycha, F. [CHU Louis Mourier, Unitede Medecine Nucleaire Assistance Publique-Hopitaux de Paris, 92 - Colombes (France); Israel, S. [CEGELEC NDT et la gestion des sources radioactives (France); Auboiroux, B. [APAVE (France); Chartier, P. [DRIRE de Basse-Normandie, Div. Surete Nucleaire et Radioprotection, 14 - Caen (France)

    2005-07-01

    Organized by the section of technical protection of the French society of radiation protection ( S.F.R.P.), these two days had for objective to review the evolution of the rule relative to the sources of ionising radiations 'sealed and unsealed radioactive sources, electric generators'. They addressed all the actors concerned by the implementation of the new regulatory system in the different sectors of activities ( research, medicine and industry): Authorities, manufacturers, and suppliers of sources, holders and users, bodies involved in the approval of sources, carriers. (N.C.)

  6. Wave field synthesis of moving virtual sound sources with complex radiation properties.

    Science.gov (United States)

    Ahrens, Jens; Spors, Sascha

    2011-11-01

    An approach to the synthesis of moving virtual sound sources with complex radiation properties in wave field synthesis is presented. The approach exploits the fact that any stationary sound source of finite spatial extent radiates spherical waves at sufficient distance. The angular dependency of the radiation properties of the source under consideration is reflected by the amplitude and phase distribution on the spherical wave fronts. The sound field emitted by a uniformly moving monopole source is derived and the far-field radiation properties of the complex virtual source under consideration are incorporated in order to derive a closed-form expression for the loudspeaker driving signal. The results are illustrated via numerical simulations of the synthesis of the sound field of a sample moving complex virtual source.

  7. Device for real time location of a radiation source. Dispositif de localisation en temps reel de sources de rayonnement

    Energy Technology Data Exchange (ETDEWEB)

    Simonet, G.

    1991-04-12

    The present invention uses a luminescent screen for conversion of radiation from the source into light, the screen is also transparent to the light coming from the observed zone, and a camera optically coupled to the screen, eventually with optical fibers giving through electric signals an image of the zone and of the sources.

  8. Python fiber optic seal

    Energy Technology Data Exchange (ETDEWEB)

    Ystesund, K.; Bartberger, J.; Brusseau, C.; Fleming, P.; Insch, K.; Tolk, K.

    1993-08-01

    Sandia National Laboratories has developed a high security fiber optic seal that incorporates tamper resistance features that are not available in commercial fiber optic seals. The Python Seal is a passive fiber optic loop seal designed to give indication of unauthorized entry. The seal includes a fingerprint feature that provides seal identity information in addition to the unique fiber optic pattern created when the seal is installed. The fiber optic cable used for the seal loop is produced with tamper resistant features that increase the difficulty of attacking that component of a seal. A Seal Reader has been developed that will record the seal signature and the fingerprint feature of the seal. A Correlator software program then compares seal images to establish a match or mismatch. SNL is also developing a Polaroid reader to permit hard copies of the seal patterns to be obtained directly from the seal.

  9. Natural Sources of Radiation Exposure and the Teaching of Radioecology

    Science.gov (United States)

    Anjos, R. M.; Veiga, R.; Carvalho, C.; Sanches, N.; Estellita, L.; Zanuto, P.; Queiroz, E.; Macario, K.

    2008-01-01

    We have developed an experimental activity that introduces concepts of the natural ionizing radiation and its interaction with our contemporary environment that can be used with students from secondary to college level. The experiment is based on the use of traditional and cheap portable Geiger-Muller detectors as survey meters for "in situ"…

  10. Terahertz radiation source using a high-power industrial electron ...

    Indian Academy of Sciences (India)

    We propose that high-power electron beam from such an industrial linac can first pass through an undulator to generate useful terahertz (THz) radiation, and the spent electron beam coming out of the undulator can still be used for the intended industrial applications. This will enhance the utilization of a high-power industrial ...

  11. III. Biological effects of radiation from external and internal sources

    Energy Technology Data Exchange (ETDEWEB)

    Stone, R.S.

    1948-05-24

    This report focuses on the hemotological effects of total body irradiation from external and internal sources observed in patients treated for arthritis with radioactive phosphorus administered intravenously.

  12. Source parameters and radiation efficiency for intermediate-depth earthquakes in Northeast Japan

    NARCIS (Netherlands)

    Nishitsuji, Y.; Mori, J.

    2013-01-01

    We estimated source parameters of 216 intermediate-depth (65–150 km) earthquakes (Mw 4.0–7.0) in the Pacific slab beneath Japan along using Hi-net data. We made determinations of static stress drop, radiated energy and radiation efficiency, along with estimates of the whole path attenuation, to

  13. Globally sourced mineral commodities used in U.S. Navy SEAL gear—An illustration of U.S. net import reliance

    Science.gov (United States)

    Brainard, Jamie; Nassar, Nedal T.; Gambogi, Joseph; Baker, Michael S.; Jarvis, Michael T.

    2018-01-25

    A U.S. Navy SEAL (an acronym for sea, air, land) carries gear containing at least 23 nonfuel mineral commodities for which the United States is greater than 50 percent net import reliant. The graphics display the leading world producers of selected nonfuel mineral commodities used to manufacture U.S. Navy SEAL gear. SEALs are members of the U.S. Navy's special operations forces.

  14. Turbine with radial acting seal

    Energy Technology Data Exchange (ETDEWEB)

    Eng, Darryl S; Ebert, Todd A

    2016-11-22

    A floating brush seal in a rim cavity of a turbine in a gas turbine engine, where the floating brush seal includes a seal holder in which the floating brush seal floats, and a expandable seal that fits within two radial extending seal slots that maintains a seal with radial displacement of the floating brush seal and the seal holder.

  15. The electromagnetic radiation from simple sources in the presence of a homogeneous dielectric sphere

    Science.gov (United States)

    Mason, V. B.

    1973-01-01

    In this research, the effect of a homogeneous dielectric sphere on the electromagnetic radiation from simple sources is treated as a boundary value problem, and the solution is obtained by the technique of dyadic Green's functions. Exact representations of the electric fields in the various regions due to a source located inside, outside, or on the surface of a dielectric sphere are formulated. Particular attention is given to the effect of sphere size, source location, dielectric constant, and dielectric loss on the radiation patterns and directivity of small spheres (less than 5 wavelengths in diameter) using the Huygens' source excitation. The computed results are found to closely agree with those measured for waveguide-excited plexiglas spheres. Radiation patterns for an extended Huygens' source and for curved electric dipoles located on the sphere's surface are also presented. The resonance phenomenon associated with the dielectric sphere is studied in terms of the modal representation of the radiated fields. It is found that when the sphere is excited at certain frequencies, much of the energy is radiated into the sidelobes. The addition of a moderate amount of dielectric loss, however, quickly attenuates this resonance effect. A computer program which may be used to calculate the directivity and radiation pattern of a Huygens' source located inside or on the surface of a lossy dielectric sphere is listed.

  16. Polymer research at synchrotron radiation sources: symposium proceedings

    Energy Technology Data Exchange (ETDEWEB)

    Russell, T.P.; Goland, A.N. (eds.)

    1985-01-01

    The twenty-two papers are arranged into eleven sessions entitled: general overviews; time-resolved x-ray scattering; studies using fluorescence, ion-containing polymers; time-resolved x-ray scattering; novel applications of synchrotron radiation; phase transitions in polymers; x-ray diffraction on polymers; recent detector advances; complementary light, x-ray and neutron studies; and neutron scattering studies. Seven of the papers are processed separately; three of the remainder have been previously processed. (DLC)

  17. Terahertz radiation source using a high-power industrial electron ...

    Indian Academy of Sciences (India)

    2017-03-27

    Mar 27, 2017 ... from such an industrial linac can first pass through an undulator to generate useful terahertz (THz) radiation, and the spent electron ..... speed and the speed of ponderomotive wave, requiring. 20. 40. 60. 80. 100. 120. 140. 1.0. 1.5. 2.0. 2.5. 3.0. 3.5. 4.0. 4.5. 5.0. Normalized emittance εn. (mm−mrad). P cen.

  18. Preparation of Radium and Other Spent Sealed Sources Containing Long-Lived Radonuclides to Long-Term Storage

    Energy Technology Data Exchange (ETDEWEB)

    Arustamov, A. E.; Ojovan, M. I.; Semenov, K. N.; Sobolev, I. A.

    2003-02-26

    At present time management of radioactive waste containing long-lived a radionuclides, is one of the most serious problems. The complexity of the management this kind of waste is due to extended half-life of these radionuclides. Hence it is difficult to predict not only long-term behavior of packages with waste, but also conditions of containing geological medium. The spent sources containing long-lived radionuclides are not suitable for disposal in shallow ground repositories. They must be temporary stored in special engineered structures. Long terms storage of these sources require application of additional measures for diminishing of risk of incidents with them.

  19. The space-time outside a source of gravitational radiation: the axially symmetric null fluid

    Energy Technology Data Exchange (ETDEWEB)

    Herrera, L. [Universidad Central de Venezuela, Escuela de Fisica, Facultad de Ciencias, Caracas (Venezuela, Bolivarian Republic of); Universidad de Salamanca, Instituto Universitario de Fisica Fundamental y Matematicas, Salamanca (Spain); Di Prisco, A. [Universidad Central de Venezuela, Escuela de Fisica, Facultad de Ciencias, Caracas (Venezuela, Bolivarian Republic of); Ospino, J. [Universidad de Salamanca, Departamento de Matematica Aplicada and Instituto Universitario de Fisica Fundamental y Matematicas, Salamanca (Spain)

    2016-11-15

    We carry out a study of the exterior of an axially and reflection symmetric source of gravitational radiation. The exterior of such a source is filled with a null fluid produced by the dissipative processes inherent to the emission of gravitational radiation, thereby representing a generalization of the Vaidya metric for axially and reflection symmetric space-times. The role of the vorticity, and its relationship with the presence of gravitational radiation is put in evidence. The spherically symmetric case (Vaidya) is, asymptotically, recovered within the context of the 1 + 3 formalism. (orig.)

  20. A biotechnological project with a gamma radiation source of 100,000 Ci

    Science.gov (United States)

    Lombardo, J. H.; Smolko, E. E.

    A project for the production of radiovaccines and other bio-medical products is presented which includes a radiation facility provided with a gamma ray source equivalent to 100,000 Ci of Co-60. The whole process incorporates novel basic features in virus production and inactivation steps. The former is carried out in animals previously subjected to immunodepression through electromagnetic radiation. The later is obtained at low temperatures by using either electromagnetic or particle radiations. A vaccine manufacture process is shown to illustrate the utilization of ionizing radiations to obtain a foot and mouth disease virus (FMDV) vaccine with good antigenic quality and low cost.

  1. Radiation Tolerant Low Power Precision Time Source Project

    Data.gov (United States)

    National Aeronautics and Space Administration — The availability of small, low power atomic clocks is now a reality for ground-based and airborne navigation systems. Kernco's Low Power Precision Time Source...

  2. 10 CFR 171.16 - Annual fees: Materials licensees, holders of certificates of compliance, holders of sealed source...

    Science.gov (United States)

    2010-01-01

    ... Heap Leach facilities 31,200 (b) Basic In Situ Recovery facilities 29,700 (c) Expanded In Situ Recovery..., heap-leaching, ore buying stations, ion exchange facilities and in-processing of ores containing source... than power reactors and spent fuel storage/reactor decommissioning, the in-situ leach rulemaking, and...

  3. Study and methodology development for quality control in the production process of iodine-125 radioactive sealed sources applied to brachytherapy; Estudo e desenvolvimento de metodologia para controle de qualidade em processo de producao de fontes seladas de iodo-125 para aplicacao em braquiterapia

    Energy Technology Data Exchange (ETDEWEB)

    Moura, Joao Augusto

    2009-07-01

    Today cancer is the second cause of death by disease in several countries, including Brazil. Excluding skin cancer, prostate cancer is the most incident in the population. Prostate tumor can be treated by several ways, including brachytherapy, which consists in introducing sealed radioactive sources (Iodine - 125 seeds) inside the tumor. The target region of treatment receives a high radiation dose, but healthy neighbor tissues receive a significantly reduced radiation dose. The seed is made of a welding sealed titanium capsule, 0.8 mm external diameter and 4.5 mm length, enclosing a 0.5 mm diameter silver wire with Iodine-125 adsorbed. After welded, the seeds have to be submitted to a leak test to prevent any radioactive material release. The aims of this work were: (a) the study of the different leakage test methods applied to radioactive seeds and recommended by the ISO 997820, (b) the choice of the appropriate method and (c) the flowchart determination of the process to be used during the seeds production. The essays exceeded the standards with the use of ultra-sound during immersion and the corresponding benefits to leakage detection. Best results were obtained with the immersion in distilled water at 20 degree C for 24 hours and distilled water at 70 degree C for 30 minutes. These methods will be used during seed production. The process flowchart has all the phases of the leakage tests according to the sequence determined in the experiments. (author)

  4. Triple acting radial seal

    Science.gov (United States)

    Ebert, Todd A [West Palm Beach, FL; Carella, John A [Jupiter, FL

    2012-03-13

    A triple acting radial seal used as an interstage seal assembly in a gas turbine engine, where the seal assembly includes an interstage seal support extending from a stationary inner shroud of a vane ring, the interstage seal support includes a larger annular radial inward facing groove in which an outer annular floating seal assembly is secured for radial displacement, and the outer annular floating seal assembly includes a smaller annular radial inward facing groove in which an inner annular floating seal assembly is secured also for radial displacement. A compliant seal is secured to the inner annular floating seal assembly. The outer annular floating seal assembly encapsulates the inner annular floating seal assembly which is made from a very low alpha material in order to reduce thermal stress.

  5. Damper Spring For Omega Seal

    Science.gov (United States)

    Maclaughlin, Scott T.; Montgomery, Stuart K.

    1993-01-01

    Damper spring reduces deflections of omega-cross-section seal, reducing probability of failure and extending life of seal. Spring is split ring with U-shaped cross section. Placed inside omega seal and inserted with seal into seal cavity. As omega seal compressed into cavity, spring and seal make contact near convolution of seal, and spring becomes compressed also. During operation, when seal dynamically loaded, spring limits deflection of seal, reducing stress on seal.

  6. The synchrotron radiation angiography program at the national synchrotron light source

    Energy Technology Data Exchange (ETDEWEB)

    Thomlinson, W.; Gmuer, N.

    1987-01-01

    The National Synchrotron Light Source (NSLS) angiography program is under development. The program is a collaboration between the Stanford University Angiography Project and the NSLS. A 180 m/sup 2/ clinical facility has been built. A beam line is being constructed to utilize a superconducting wiggler radiation source. Projected start-up date for the NSLS program is Summer 1988.

  7. A Radiation Analysis of 500W RTPV System having Cylindrical Sources

    Science.gov (United States)

    Cheon, Seong Jae; Hong, Ser Gi; Nam, Young Suk; Lee, Jung Hun

    2017-09-01

    In this work, the radiation shielding analysis for a RTPV (Radioisotope Thermo-Photo-Voltaic) device using 238PuO2 was performed to estimate the radiation dose distribution over source region and radiation doses in a specified tally zone. The radiation source intensities and spectra were evaluated with ORIGEN-S and the detailed shielding analyses were performed with MCNP6 and MONACO/MAVRIC (in SCALE 6.1). In particular, comparative shielding analysis using two different types of RTPV (cubic homogeneous source type and cylindrical heterogeneous source type) were performed to show their relative performances. The results show that the RTPV device using the heterogeneous cylindrical source type has lower dose values by 5 11% depending on the packing factor at the measurement cell than the one using the homogeneous cubic source type. The additional thermal analysis using COMSOL shows that the temperature distribution of the heterogeneous cylindrical source type is more flat than that of a homogeneous cubic source type.

  8. Localization of the gamma-radiation sources using the gamma-visor

    Directory of Open Access Journals (Sweden)

    Ivanov Kirill E.

    2008-01-01

    Full Text Available The search of the main gamma-radiation sources at the site of the temporary storage of solid radioactive wastes was carried out. The relative absorbed dose rates were measured for some of the gamma-sources before and after the rehabilitation procedures. The effectiveness of the rehabilitation procedures in the years 2006-2007 was evaluated qualitatively and quantitatively. The decrease of radiation background at the site of the temporary storage of the solid radioactive wastes after the rehabilitation procedures allowed localizing the new gamma-source.

  9. Dazzling new light source opens at Stanford synchrotron radiation laboratory

    CERN Multimedia

    2004-01-01

    SPEAR3, the Stanford Positron Electron Asymmetric Ring, was formally opened at a dedication ceremony at the Stanford Linear Accelerator Center on Jan. 29. It incorporates the latest technology to make it competitive with the best synchrotron sources in the world (1/2 page)

  10. Radiation Thermometry—Sources of Uncertainty During Contactless Temperature Measurement

    Science.gov (United States)

    Reichel, Denise; Schumann, T.; Skorupa, W.; Lerch, W.; Gelpey, J.

    Short Time Annealing on a microsecond to nanosecond scale presents new challenges to temperature measurement. Pyrometers are widely used owing to their commercial availability, short response time, easy handling and contactless operation. However, they hold a source for considerable measurement errors. False readings are easily gained producing large errors during temperature measurement.

  11. Internet as a Source of Misconception: "Radiation and Radioactivity"

    Science.gov (United States)

    Acar Sesen, Burcin; Ince, Elif

    2010-01-01

    The purpose of this study is to examine students' usage styles of the Internet for seeking information and to investigate whether information obtained from the Internet is a source of misconceptions. For this reason, a two-stage study was conducted. At the first stage, a questionnaire was developed to get information about students' Internet usage…

  12. Safety and security of radiation sources in the aftermath of 11 September 2001.

    Science.gov (United States)

    Lubenau, Joel O; Strom, Daniel J

    2002-08-01

    The attack on the United States on 11 September 2001 resulted in an increased awareness of the need for safety and security measures to protect against terrorism. The potential use of radiation sources in terrorism, in particular radioactive sources, was recognized prior to 11 September 2001, but has taken on new significance since. The planning of security measures for radioactive sources must take greater account of the potential for deliberate acts to attack or use radioactive sources to expose people and cause contamination. The potential consequences of an act of terrorism using radioactive sources can be gauged from the consequences of serious accidents that have occurred involving radioactive sources. These include fatal and injurious radiation exposures, contamination of the environment, and serious economic and psychosocial costs the total effect of which is mass disruption. Steps are being taken to improve security for radioactive sources but strategic approaches that can minimize the threat of radiological terrorism should be considered. When justifying a practice that uses radioactive sources, the potential for diversion or use in terrorism should be considered to be a detriment. In this regard, the consideration and development of alternatives to radioactive sources, such as radiation producing machines, have been recommended by terrorism experts as measures to reduce the threat of radiological terrorism. If a practice using radioactive sources is determined to be justified, the need for special security measures to protect against terrorism should then become part of the safety assessment.

  13. Morphology of the nonspherically decaying radiation beam generated by a rotating superluminal source.

    Science.gov (United States)

    Ardavan, Houshang; Ardavan, Arzhang; Singleton, John; Fasel, Joseph; Schmidt, Andrea

    2007-08-01

    We consider the nonspherically decaying radiation field that is generated by a polarization current with a superluminally rotating distribution pattern in vacuum, a field that decays with the distance R(P) from its source as R(P)(-1/2), instead of R(P)(-1). It is shown (i) that the nonspherical decay of this emission remains in force at all distances from its source independently of the frequency of the radiation, (ii) that the part of the source that makes the main contribution toward the value of the nonspherically decaying field has a filamentary structure whose radial and azimuthal widths become narrower (as R(P)(-2) and R(P)(-3), respectively) the farther the observer is from the source, (iii) that the loci on which the waves emanating from this filament interfere constructively delineate a radiation subbeam that is nondiffracting in the polar direction, (iv) that the cross-sectional area of each nondiffracting subbeam increases as R(P), instead of R(P)(2), so that the requirements of conservation of energy are met by the nonspherically decaying radiation automatically, and (v) that the overall radiation beam within which the field decays nonspherically consists, in general, of the incoherent superposition of such coherent nondiffracting subbeams. These findings are related to the recent construction and use of superluminal sources in the laboratory and numerical models of the emission from them. We also briefly discuss the relevance of these results to the giant pulses received from pulsars.

  14. Multi-source driven capillary plane radiation air conditioning system

    Science.gov (United States)

    Hu, Juanjuan; Qu, Mofeng; Wang, Huasheng; Ni, Shiyao

    2017-08-01

    A new absorption refrigeration system, which is driven by solar energy, biomass energy and geothermal energy simultaneously, was designed with capillaries as its radiation surface. Likewise, variations of water temperature in the capillaries with the change in both time and its flow rate were experimentally researched as well as how COP of the system varies with the surrounding temperature. The following conclusions have been obtained: Common refrigeration demand can be met by the system after its operation in 1 hour; with the increase in water flow rate in the capillaries, its temperature, which drops down after an increase, gets its peak value at the flow rate of 4.5-5.5 L/min; COP of the system decreases with the rise of surrounding temperature, thus it's better to keep it from direct sunlight. With the utilization of natural energy and the structure of capillaries, the system's advantages in simple structure, low cost, environment-friendly working process and nice performance lead to promising application prospects, especially in residence refrigeration in countryside.

  15. [Correlativity analysis based on radiation spectrum of correlated color temperature and thermodynamic temperature of a radiating source].

    Science.gov (United States)

    Fu, Tai-ran; Cheng, Xiao-fang; Zhong, Mao-hua; Yang, Zang-jian

    2006-11-01

    Correlated color temperature, which describes the chromaticity characteristics of a radiating source, is different from its thermodynamic temperature derived from primary spectrum pyrometry. However, establishing their mathematical relationship is feasible. Therefore, the authors theoretically analyzed the variation rule of the correlativity difference between the correlated color temperature of the source and its thermodynamic temperature with the emissivity parameter. And the authors gave the corresponding numerical simulation results. The above theoretical and numerical discussions will make it possible that a colorimeter used to measure the correlated color temperature serves as a pyrometer to realize the measurement of the thermodynamic temperature.

  16. Correlations between 21-cm radiation and the cosmic microwave background from active sources

    Science.gov (United States)

    Berndsen, Aaron; Pogosian, Levon; Wyman, Mark

    2010-09-01

    Neutral hydrogen is ubiquitous, absorbing and emitting 21-cm radiation throughout much of the Universe's history. Active sources of perturbations, such as cosmic strings, would generate simultaneous perturbations in the distribution of neutral hydrogen and in the cosmic microwave background (CMB) radiation from recombination. Moving strings would create wakes leading to 21-cm brightness fluctuations, while also perturbing CMB light via the Gott-Kaiser-Stebbins effect. This would lead to spatial correlations between the 21-cm and CMB anisotropies. Passive sources, like inflationary perturbations, predict no cross-correlations prior to the onset of reionization. Thus, observation of any cross-correlation between CMB and 21-cm radiation from dark ages would constitute evidence for new physics. We calculate the cosmic string-induced correlations between CMB and 21-cm radiation and evaluate their observability.

  17. Sources of gravitational radiation and prospects for their detection

    OpenAIRE

    Flanagan, Eanna E

    1998-01-01

    In the coming decade, the LIGO/VIRGO/GEO network of ground-based kilometer-scale laser interferometer gravitational wave detectors will open up a new astronomical window on the Universe: gravitational waves in the frequency band 10 to 10^4 Hz. In addition, if the proposed, 5 million kilometer long, space based interferometer LISA flies, another window will be opened in the frequency band 10^(-4) to 1 Hz. I review the various possible sources that might be detected in these frequency bands, an...

  18. Laser-plasma SXR/EUV sources: adjustment of radiation parameters for specific applications

    Science.gov (United States)

    Bartnik, A.; Fiedorowicz, H.; Fok, T.; Jarocki, R.; Kostecki, J.; Szczurek, A.; Szczurek, M.; Wachulak, P.; Wegrzyński, Ł.

    2014-12-01

    In this work soft X-ray (SXR) and extreme ultraviolet (EUV) laser-produced plasma (LPP) sources employing Nd:YAG laser systems of different parameters are presented. First of them is a 10-Hz EUV source, based on a double-stream gaspuff target, irradiated with the 3-ns/0.8J laser pulse. In the second one a 10 ns/10 J/10 Hz laser system is employed and the third one utilizes the laser system with the pulse shorten to approximately 1 ns. Using various gases in the gas puff targets it is possible to obtain intense radiation in different wavelength ranges. This way intense continuous radiation in a wide spectral range as well as quasi-monochromatic radiation was produced. To obtain high EUV or SXR fluence the radiation was focused using three types of grazing incidence collectors and a multilayer Mo/Si collector. First of them is a multfoil gold plated collector consisted of two orthogonal stacks of ellipsoidal mirrors forming a double-focusing device. The second one is the ellipsoidal collector being part of the axisymmetrical ellipsoidal surface. Third of the collectors is composed of two aligned axisymmetrical paraboloidal mirrors optimized for focusing of SXR radiation. The last collector is an off-axis ellipsoidal multilayer Mo/Si mirror allowing for efficient focusing of the radiation in the spectral region centered at λ = 13.5 ± 0.5 nm. In this paper spectra of unaltered EUV or SXR radiation produced in different LPP source configurations together with spectra and fluence values of focused radiation are presented. Specific configurations of the sources were assigned to various applications.

  19. Positron energy distributions from a hybrid positron source based on channeling radiation

    Energy Technology Data Exchange (ETDEWEB)

    Azadegan, B.; Mahdipour, A. [Hakim Sabzevari University, P.O. Box 397, Sabzevar (Iran, Islamic Republic of); Dabagov, S.B. [INFN LNF, Via E. Fermi 40, 00044 Frascati (RM) (Italy); RAS P.N. Lebedev Physical Institute and NRNU MEPhI, Moscow (Russian Federation); Wagner, W., E-mail: w.wagner@hzdr.de [HZDR Dresden, P.O. Box 510119, 01314 Dresden (Germany)

    2013-08-15

    A hybrid positron source which is based on the generation of channeling radiation by relativistic electrons channeled along different crystallographic planes and axes of a tungsten single crystal and subsequent conversion of radiation into e{sup +}e{sup −}-pairs in an amorphous tungsten target is described. The photon spectra of channeling radiation are calculated using the Doyle–Turner approximation for the continuum potentials and classical equations of motion for channeled particles to obtain their trajectories, velocities and accelerations. The spectral-angular distributions of channeling radiation are found applying classical electrodynamics. Finally, the conversion of radiation into e{sup +}e{sup −}-pairs and the energy distributions of positrons are simulated using the GEANT4 package.

  20. Electromagnetic radiation from filamentary sources in the presence of axially magnetized cylindrical plasma scatterers

    Energy Technology Data Exchange (ETDEWEB)

    Es’kin, V. A.; Ivoninsky, A. V.; Kudrin, A. V., E-mail: kud@rf.unn.ru; Popova, L. L. [Lobachevsky University (Russian Federation)

    2017-02-15

    Electromagnetic radiation from filamentary electric-dipole and magnetic-current sources of infinite length in the presence of gyrotropic cylindrical scatterers in the surrounding free space is studied. The scatterers are assumed to be infinitely long, axially magnetized circular plasma columns parallel to the axis of the filamentary source. The field and the radiation pattern of each source are calculated in the case where the source frequency is equal to one of the surface plasmon resonance frequencies of the cylindrical scatterers. It is shown that the presence of even a single resonant magnetized plasma scatterer of small electrical radius or a few such scatterers significantly affects the total fields of the filamentary sources, so that their radiation patterns become essentially different from those in the absence of scatterers or the presence of isotropic scatterers of the same shape and size. It is concluded that the radiation characteristics of the considered sources can efficiently be controlled using their resonance interaction with the neighboring gyrotropic scatterers.

  1. Laser pumped light emitting diodes as broad area sources of coherent radiation

    Science.gov (United States)

    Rahman, Faiz; Sorel, Marc

    2006-08-01

    This paper describes the use of large area light emitting diodes, pumped with various laser sources, as extended area emitters of coherent radiation. The photon recycling takes place through the intermediary of electron hole pair formation and subsequent stimulated recombination. It is possible to generate both spontaneous and stimulated emission together and the two channels are then independent of each other. This allows the generation of a mixture of coherent and non-coherent radiation in any desired proportion. The technique described is a broad-band resonant process with diffusive feedback and can be used for generating non-collimated laser radiation for a variety of applications.

  2. Projection of needs for gamma radiation sources and other radioisotopes and assessment of alternatives for providing radiation sources

    Energy Technology Data Exchange (ETDEWEB)

    Ross, W.A.; Jensen, G.A.; Clark, L.L.; Eakin, D.E.; Jarrett, J.H.; Katayama, Y.B.; McKee, R.W.; Morgan, L.G.; Nealey, S.M.; Platt, A.M.; Tingey, G.L.

    1989-06-01

    Pacific Northwest Laboratory reviewed the projected uses and demands for a variety of nuclear byproducts. Because the major large-scale near-term demand is for gamma irradiation sources, this report concentrates on the needs for gamma sources and evaluates the options for providing the needed material. Projections of possible growth in the irradiation treatment industry indicate that there will be a need for 180 to 320 MCi of /sup 60/Co (including /sup 137/Cs equivalent) in service in the year 2000. The largest current and projected use of gamma irradiation is for the sterilization of medical devices and disposable medical supplies. Currently, 40% of US disposable medical products are treated by irradiation, and within 10 years it is expected that 90% will be treated in this manner. Irradiation treatment of food for destruction of pathogens or parasites, disinfestation, or extension of allowable storage periods is estimated to require an active inventory of 75 MCi of /sup 60/Co-equivalent gamma source in about a decade. 90 refs., 7 figs., 25 tabs.

  3. Influence of Size of Source Effect on Accuracy of LWIR Radiation Thermometers

    Directory of Open Access Journals (Sweden)

    Cywiak David

    2016-12-01

    Full Text Available Determining the size of source effect of a radiation thermometer is not an easy task and manufacturers of these thermometers usually do not indicate the deviation to the measured temperature due to this effect. It is one of the main uncertainty components when measuring with a radiation thermometer and it may lead to erroneous estimation of the actual temperature of the measured target. We present an empiric model to estimate the magnitude of deviation of the measured temperature with a long-wavelength infrared radiation thermometer due to the size of source effect. The deviation is calculated as a function of the field of view of the thermometer and the diameter of the radiating source. For thermometers whose field of view size at 90% power is approximately equal to the diameter of the radiating source, it was found that this effect may lead to deviations of the measured temperature of up to 6% at 200ºC and up to 14% at 500ºC. Calculations of the temperature deviation with the proposed model are performed as a function of temperature and as a function of the first order component of electrical signal.

  4. A survey of actuator shaft sealing techniques for extended space missions

    Science.gov (United States)

    Hotz, G. M.

    1972-01-01

    Actuators for control and articulation aboard Mariner spacecraft have employed output shaft seals to maintain an internal gaseous atmosphere. On future missions, considerably greater expected lifetimes, temperature ranges, and radiation exposures have led to a need to determine the limitations of the present O-ring output shaft seal and to examine other candidate seals. Seals suited both to dynamic and static sealing were examined for potential use in three specific actuator applications and the following candidate seals were selected: (a) O-ring seal, (b) chevron seal, (c) bellows seal (linear actuator only), (d) magnetic fluid seal (rotary actuators only) and as a backup seal to any of the foregoing, (e) the labyrinth seal.

  5. Investigation on Main Radiation Source at Operation Floor of Fukushima Daiichi Nuclear Power Station Unit 4

    Science.gov (United States)

    Hirayama, Hideo; Kondo, Kenjiro; Suzuki, Seishiro; Hamamoto, Shimpei; Iwanaga, Kohei

    2017-09-01

    Pulse height distributions were measured using a LaBr3 detector set in a 1 cm lead collimator to investigate main radiation source at the operation floor of Fukushima Daiichi Nuclear Power Station Unit 4. It was confirmed that main radiation source above the reactor well was Co-60 from the activated steam dryer in the DS pool (Dryer-Separator pool) and that at the standby area was Cs-134 and Cs-137 from contaminated buildings and debris at the lower floor. Full energy peak count rate of Co-60 was reduced about 1/3 by 12mm lead sheet placed on the floor of the fuel handling machine.

  6. Development of sealed radioactive sources immobilized in epoxy resin for verification of detectors used in nuclear medicine; Desenvolvimento de fontes radioativas seladas imobilizadas em resina epoxi para verificacao de detectores utilizados em medicina nuclear

    Energy Technology Data Exchange (ETDEWEB)

    Tiezzi, Rodrigo

    2016-07-01

    The radioactive sealed sources are used in verification ionization chamber detectors, which measure the activity of radioisotopes used in several areas, such as in nuclear medicine. The measurement of the activity of radioisotopes must be made with accuracy, because it is administered to a patient. To ensure the proper functioning of the ionization chamber detectors, standardized tests are set by the International Atomic Energy Agency (IAEA) and the National Nuclear Energy Commission using sealed radioactive sources of Barium-133, Cesium-137 and Cobalt-57. The tests assess the accuracy, precision, reproducibility and linearity of response of the equipment. The focus of this work was the study and the development of these radioactive sources with standard Barium-133 and Cesium-137,using a polymer, in case commercial epoxy resin of diglycidyl ether of bisphenol A (DGEBA) and a curing agent based on modified polyamine diethylenetriamine (DETA), to immobilize the radioactive material. The polymeric matrix has the main function of fix and immobilize the radioactive contents not allowing them to leak within the technical limits required by the standards of radiological protection in the category of characteristics of a sealed source and additionally have the ability to retain the emanation of any gases that may be formed during the manufacture process and the useful life of this artifact. The manufacturing process of a sealed source standard consists of the potting ,into bottle standardized geometry, in fixed volume of a quantity of a polymeric matrix within which is added and dispersed homogeneously to need and exact amount in activity of the radioactive materials standards. Accordingly, a study was conducted for the choice of epoxy resin, analyzing its characteristics and properties. Studies and tests were performed, examining the maximum miscibility of the resin with the water (acidic solution, simulating the conditions of radioactive solution), loss of mechanical and

  7. IMPACTS OF SOURCE TERM HETEROGENEITIES ON WATER PATHWAY DOSE.

    Energy Technology Data Exchange (ETDEWEB)

    SULLIVAN, T.; GUSKOV, A.; POSKAS, P.; RUPERTI, N.; HANUSIK, V.; ET AL.

    2004-09-15

    Radioactive sealed sources are used extensively throughout the world in different field and various activities such as medicine, agriculture, industry, research, education military applications, as well as nuclear facilities. The International Basic Safety Standards for Protection against Ionizing Radiation and for the Safety of Radiation sources [1] defines a sealed source as ''radioactive material that is (a) permanently sealed in capsule or (b) closely bounded and in a solid form. The capsule or material of sealed source shall be strong enough to maintain remain leak free under the conditions of use and wear for which the source was designed, also under foreseeable mishaps''. When a radioactive sealed source is no longer needed, or becomes unfit for the intended application it is considered spent. A spent sealed source is not necessarily a waste because it can be used in other applications. If for any technical or economic reason (decay, obsolete equipment and technique, worn out equipment) no further use is foreseen, the spent sealed source is considered spent and becomes radioactive waste [2] [3]. In addition, a source may be taken out of service temporarily or indefinitely. In this case the source is out of used (''disused'') but not considered spent [4]. Sources that are not in active use and have not being declared as spent are considered as disused sealed sources [4]. Considering the potential radiation hazards associated with such waste it has to be managed and disposed of in a way that will ensure that the potential radiation hazards are adequately managed and controlled in compliance with the appropriate safety principles and criteria. It is recognized that there exists today experience and means for all steps in the management of disused sealed sources, except disposal of [2]. In many countries, disused sealed sources represent a part of the radioactive waste inventory being characterized generally with high

  8. Performance of light sources and radiation sensors under low gravity realized by parabolic airplane flights

    Science.gov (United States)

    Hirai, Hiroaki; Kitaya, Yoshiaki; Hirai, Takehiro

    A fundamental study was conducted to establish an experimental system for space farming. Since to ensure optimal light for plant cultivation in space is of grave importance, this study examined the performance of light sources and radiation sensors under microgravity conditions created during the parabolic airplane flight. Three kinds of light sources, a halogen bulb, a fluorescent tube, and blue and red LEDs, and ten models of radiation sensors available in the market were used for the experiment. Surface temperature of the light sources, output signals from the radiation sensors, spectroscopic characteristics were measured at the gravity levels of 0.01, 1.0 and 1.8 G for 20 seconds each during parabolic airplane flights. As a result, the performance of the halogen lamp was affected the most by the gravity level among the three light sources. Under the microgravity conditions which do not raise heat convection, the temperature of the halogen lamp rose and the output of the radiation sensors increased. Spectral distributions of the halogen lamp indicated that peak wavelength appeared the highest at the level of 0.01G, which contributed to the increase in light intensity. In the case of red and blue LEDs, which are promising light sources in space farming, the temperature of both LED chips rose but irradiance from red LED increased and that from blue LED decreased under microgravity conditions due to the different thermal characteristics.

  9. Partial coherence and imperfect optics at a synchrotron radiation source modeled by wavefront propagation

    Science.gov (United States)

    Laundy, David; Alcock, Simon G.; Alianelli, Lucia; Sutter, John P.; Sawhney, Kawal J. S.; Chubar, Oleg

    2014-09-01

    A full wave propagation of X-rays from source to sample at a storage ring beamline requires simulation of the electron beam source and optical elements in the beamline. The finite emittance source causes the appearance of partial coherence in the wave field. Consequently, the wavefront cannot be treated exactly with fully coherent wave propagation or fully incoherent ray tracing. We have used the wavefront code Synchrotron Radiation Workshop (SRW) to perform partially coherent wavefront propagation using a parallel computing cluster at the Diamond Light Source. Measured mirror profiles have been used to correct the wavefront for surface errors.

  10. Flexible sliding seal

    Science.gov (United States)

    Wallenhorst, E. L.

    1980-01-01

    Circular seal both slides and flexes to accomodate relative motion between two sealed members. Originally developed for Space Shuttle orbiter, it contains sliding seal to accommodate engine gimbaling and flexible seal that absorbs forward motion at high thrust of engine heat shield relative to airframe. Other possible applications are in support structures of heavy machinery and vehicle engines. Flexible sliding seal is ring about 7 feet in diameter and can withstand temperatures up to 1,600 F.

  11. Brilliant radiation sources by laser-plasma accelerators and optical undulators

    Energy Technology Data Exchange (ETDEWEB)

    Debus, Alexander

    2012-09-06

    This thesis investigates the use of high-power lasers for synchrotron radiation sources with high brilliance, from the EUV to the hard X-ray spectral range. Hereby lasers accelerate electrons by laser-wakefield acceleration (LWFA), act as optical undulators, or both. Experimental evidence shows for the first time that LWFA electron bunches are shorter than the driving laser and have a length scale comparable to the plasma wavelength. Furthermore, a first proof of principle experiment demonstrates that LWFA electrons can be exploited to generate undulator radiation. Building upon these experimental findings, as well as extensive numerical simulations of Thomson scattering, the theoretical foundations of a novel interaction geometry for laser-matter interaction are developed. This new method is very general and when tailored towards relativistically moving targets not being limited by the focusability (Rayleigh length) of the laser, while it does not require a waveguide. In a theoretical investigation of Thomson scattering, the optical analogue of undulator radiation, the limits of Thomson sources in scaling towards higher peak brilliances are highlighted. This leads to a novel method for generating brilliant, highly tunable X-ray sources, which is highly energy efficient by circumventing the laser Rayleigh limit through a novel traveling-wave Thomson scattering (TWTS) geometry. This new method suggests increases in X-ray photon yields of 2-3 orders of magnitudes using existing lasers and a way towards efficient, optical undulators to drive a free-electron laser. The results presented here extend far beyond the scope of this work. The possibility to use lasers as particle accelerators, as well as optical undulators, leads to very compact and energy efficient synchrotron sources. The resulting monoenergetic radiation of high brilliance in a range from extreme ultraviolet (EUV) to hard X-ray radiation is of fundamental importance for basic research, medical

  12. Rotary shaft sealing assembly

    Science.gov (United States)

    Dietle, Lannie L.; Schroeder, John E.; Kalsi, Manmohan S.; Alvarez, Patricio D.

    2010-09-21

    A rotary shaft sealing assembly in which a first fluid is partitioned from a second fluid in a housing assembly having a rotary shaft located at least partially within. In one embodiment a lip seal is lubricated and flushed with a pressure-generating seal ring preferably having an angled diverting feature. The pressure-generating seal ring and a hydrodynamic seal may be used to define a lubricant-filled region with each of the seals having hydrodynamic inlets facing the lubricant-filled region. Another aspect of the sealing assembly is having a seal to contain pressurized lubricant while withstanding high rotary speeds. Another rotary shaft sealing assembly embodiment includes a lubricant supply providing a lubricant at an elevated pressure to a region between a lip seal and a hydrodynamic seal with a flow control regulating the flow of lubricant past the lip seal. The hydrodynamic seal may include an energizer element having a modulus of elasticity greater than the modulus of elasticity of a sealing lip of the hydrodynamic seal.

  13. Radiation source locating from distance device; Dispositif de localisation a distance de sources de rayonnement

    Energy Technology Data Exchange (ETDEWEB)

    Porcher, J.B.; Fouquet, C.; Dubart, P.; Salaun, P.

    1994-12-23

    This device is made up of a chamber with a pinhole, a radiophotoluminescent screen facing the pinhole, a latent image of the sources forming on this screen, a camera giving, in electric signal form, a zone image, optical means enabling the camera and the screen to watch the same scene, screen reading means giving, in electric signal form, a source image from the latent image and electronic means for signal processing and display, in order to superpose and visualize zone and source images. (Author). 1 fig., 3 refs.

  14. Calibration of Radiation Thermometers up to : Effective Emissivity of the Source

    Science.gov (United States)

    Kozlova, O.; Briaudeau, S.; Rongione, L.; Bourson, F.; Guimier, S.; Kosmalski, S.; Sadli, M.

    2015-08-01

    The growing demand of industry for traceable temperature measurements up to encourages improvement of calibration techniques for industrial-type radiation thermometers in this temperature range. High-temperature fixed points can be used at such high temperatures, but due to the small diameter of apertures of their cavities (3 mm), they are not adapted for the large field-of-views commonly featured by this kind of radiation thermometers. At LNE-Cnam, a Thermo Gauge furnace of 25.4 mm source aperture diameter is used as a comparison source to calibrate customers' instruments against a reference radiation thermometer calibrated according to the ITS-90 with the lowest uncertainties achievable in the Laboratory. But the furnace blackbody radiator exhibits a large temperature gradient that degrades its effective emissivity, and increases the calibration uncertainty due to the lack of information on the working spectral band of the industrial radiation thermometer. In order to estimate the corrections to apply, the temperature distribution (radial and on-axis) of the Thermo Gauge furnace blackbody radiator was characterized and the effective emissivity of the Thermo Gauge cavity was determined by three different methods. Because of this investigation, the corrections due to different fields of view and due to the different spectral bands of the reference pyrometer and the customer's pyrometer were obtained and the uncertainties on these corrections were evaluated.

  15. Effects of various radiation source characteristics on shielding requirements at the potential Yucca Mountain repository

    Energy Technology Data Exchange (ETDEWEB)

    Smith, D.W.; Miller, D.D. [Bechtel National, Inc., San Francisco, CA (United States); Hill, R.R. [Sandia National Labs., Albuquerque, NM (United States)

    1992-02-01

    This radiation shielding study provides dose rate information that can be used to estimate required shielding thicknesses for different repository configurations, including various hot cells and vaults in the waste-handling building, the boreholes in the underground emplacement area, and the transfer casks. The study determines gamma and neutron source strengths for various waste types and source geometries representative of conditions at the repository and determines dose rates as a function of shielding thickness for selected materials.

  16. Focusing of 3C144 Source Radiation by the Solar Corona

    Science.gov (United States)

    Galanin, V. V.; Derevjagin, V. G.; Kravetz, R. O.

    The research of solar corona by the compact cosmic source radiation was made on URAN-4 radio telescope. In the period from June 6 to June 20 2012 the flow of Crab nebula was measured on the 20 MHz and 25 MHz frequencies. During the eclipse we observe the great increase of 3C144 flow, which is compare with the flow of 3C461 source. Data and results of measurement analysis is presented.

  17. Active Infrared Thermography for Seal Contamination Detection in Heat-Sealed Food Packaging

    Directory of Open Access Journals (Sweden)

    Karlien D’huys

    2016-11-01

    Full Text Available Packaging protects food products from environmental influences, assuring quality and safety throughout shelf life if properly performed. Packaging quality depends on the quality of the packaging material and of the closure or seal. A common problem possibly jeopardizing seal quality is the presence of seal contamination, which can cause a decreased seal strength, an increased packaging failure risk and leak formation. Therefore, early detection and removal of seal contaminated packages from the production chain is crucial. In this work, a pulsed-type active thermography method using the heated seal bars as an excitation source was studied for detecting seal contamination. Thermal image sequences of contaminated seals were recorded shortly after sealing. The detection performances of six thermal image processing methods, based on a single frame, a fit of the cooling profiles, thermal signal reconstruction, pulsed phase thermography, principal component thermography and a matched filter, were compared. High resolution digital images served as a reference to quantify seal contamination, and processed thermal images were mapped to these references. The lowest detection limit (equivalent diameter 0.60 mm was obtained for the method based on a fit of the cooling profiles. Moreover, the detection performance of this method did not depend strongly on the time after sealing at which recording of the thermal images was started, making it a robust and generally applicable method.

  18. Conditions for radiation protection in industrial radiography

    CERN Document Server

    1999-01-01

    The leaflet specifies radiation protection requirements for industrial radiography in Norway. The regulations are directed towards companies using or distributing sealed radioactive sources, x-ray equipment or accelerators in non-destructive material testing (NDT). Technical requirements to the equipment, as well as administrative requirements for use, licensing, qualifications, handling of accidents etc. are given. (Author)

  19. Modelling the Impact of Ground Planes on Antenna Radiation Using the Method of Auxiliary Sources

    DEFF Research Database (Denmark)

    Larsen, Niels Vesterdal; Breinbjerg, Olav

    2007-01-01

    The Method of Auxiliary Sources is employed to model the impact of finite ground planes on the radiation from antennas. In many cases the computational cost of available commercial tools restricts the simulations to include only a small ground plane or, by use of the image principle, the infinitely...

  20. Development of a high-power THz radiation source for plasma diagnostics

    NARCIS (Netherlands)

    Siegrist, M. R.; Bindslev, H.; Brazis, R.; Guyomarc' h, D.; Hogge, J. P.; Moreau, P.; Raguotis, R.

    1999-01-01

    A high power radiation source in the THz range with long pulse and narrow line width is required for diagnosing fusion type plasmas by collective Thomson scattering. Gyrotrons currently meet the requirements concerning power, pulse length and line width when operating in the 50-150 GHz range. They

  1. Environmental assessment for the relocation and storage of isotopic heat sources, Hanford Site, Richland, Washington

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1997-06-01

    As part of a bilateral agreement between the Federal Minister for Research and Technology of the Federal Republic of Germany (FRG) and the DOE, Pacific Northwest National Laboratory (PNNL) developed processes for the treatment and immobilization of high-level radioactive waste. One element of this bilateral agreement was the production of sealed isotopic heat sources. During the mid-1980s, 30 sealed isotopic heat sources were manufactured. The sources contain a total of approximately 8.3 million curies consisting predominantly of cesium-137 and strontium-90 with trace amounts of transuranic contamination. Currently, the sources are stored in A-Cell of the 324 Building. Intense radiation fields from the sources are causing the cell windows and equipment to deteriorate. Originally, it was not intended to store the isotopic heat sources for this length of time in A-cell. The 34 isotopic heat sources are classified as remote handled transuranic wastes. Thirty-one of the isotopic heat sources are sealed, and seals on the three remaining isotopic heat sources have not been verified. However, a decision has been made to place the remaining three isotopic heat sources in the CASTOR cask(s). The Washington State Department of Health (WDOH) has concurred that isotopic heat sources with verified seals or those placed into CASTOR cask(s) can be considered sealed (no potential to emit radioactive air emissions) and are exempt from WAC Chapter 246-247, Radiation Protection-Air Emissions.

  2. Nuclear reactor sealing system

    Science.gov (United States)

    McEdwards, James A.

    1983-01-01

    A liquid metal-cooled nuclear reactor sealing system. The nuclear reactor includes a vessel sealed at its upper end by a closure head. The closure head comprises at least two components, one of which is rotatable; and the two components define an annulus therebetween. The sealing system includes at least a first and second inflatable seal disposed in series in an upper portion of the annulus. The system further includes a dip seal extending into a body of insulation located adjacent a bottom portion of the closure head. The dip seal comprises a trough formed by a lower portion of one of the components, and a seal blade pendently supported from the other component and extending downwardly into the trough. A body of liquid metal is contained in the trough which submerges a portion of the seal blade. The seal blade is provided with at least one aperture located above the body of liquid metal for providing fluid communication between the annulus intermediate the dip seal and the inflatable seals, and a body of cover gas located inside the vessel. There also is provided means for introducing a purge gas into the annulus intermediate the inflatable seals and the seal blade. The purge gas is introduced in an amount sufficient to substantially reduce diffusion of radioactive cover gas or sodium vapor up to the inflatable seals. The purge gas mixes with the cover gas in the reactor vessel where it can be withdrawn from the vessel for treatment and recycle to the vessel.

  3. Management of ionizing radiation sources in university, medical and industrial environments; Gestion des sources ionisantes en milieux universitaire, medical et industriel

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2000-07-01

    This conference treats several subjects relative to the use of radioactive sources. The first session comprises three articles about ionizing sources and regulation. The second session, with three articles, tackles the question of radiation protection in the use of sources in industrial field. The third session, four articles, treats the same question but in the medicine and university media. The fourth session (three articles) is devoted to the organisation of radiation protection in the case of accidents. The fifth session concerns the management of spent sources (three articles). The sixth session studies the radiation protection of sources in Europe. The seventh and final session ends with the part and coordination of actors in radiation protection in the sources management (three articles). (N.C.)

  4. Space Environment's Effects on Seal Materials

    Science.gov (United States)

    deGroh, Henry C., III; Daniels, Christopher C.; Dunlap, Patrick; Miller, Sharon; Dever, Joyce; Waters, Deborah; Steinetz, Bruce M.

    2007-01-01

    A Low Impact Docking System (LIDS) is being developed by the NASA Johnson Space Center to support future missions of the Crew Exploration Vehicle (CEV). The LIDS is androgynous, such that each system half is identical, thus any two vehicles or modules with LIDS can be coupled. Since each system half is a replica, the main interface seals must seal against each other instead of a conventional flat metal surface. These sealing surfaces are also expected to be exposed to the space environment when vehicles are not docked. The NASA Glenn Research Center (NASA GRC) is supporting this project by developing the main interface seals for the LIDS and determining the durability of candidate seal materials in the space environment. In space, the seals will be exposed to temperatures of between 50 to 50 C, vacuum, atomic oxygen, particle and ultraviolet radiation, and micrometeoroid and orbital debris (MMOD). NASA GRC is presently engaged in determining the effects of these environments on our candidate elastomers. Since silicone rubber is the only class of seal elastomer that functions across the expected temperature range, NASA GRC is focusing on three silicone elastomers: two provided by Parker Hannifin (S0-899-50 and S0-383-70) and one from Esterline Kirkhill (ELA-SA-401). Our results from compression set, elastomer to elastomer adhesion, and seal leakage tests before and after various simulated space exposures will be presented.

  5. Inboard seal mounting

    Science.gov (United States)

    Hayes, John R. (Inventor)

    1983-01-01

    A regenerator assembly for a gas turbine engine has a hot side seal assembly formed in part by a cast metal engine block having a seal recess formed therein that is configured to supportingly receive ceramic support blocks including an inboard face thereon having a regenerator seal face bonded thereto. A pressurized leaf seal is interposed between the ceramic support block and the cast metal engine block to bias the seal wear face into sealing engagement with a hot side surface of a rotary regenerator matrix.

  6. 21 CFR 179.21 - Sources of radiation used for inspection of food, for inspection of packaged food, and for...

    Science.gov (United States)

    2010-04-01

    ... CONSUMPTION (CONTINUED) IRRADIATION IN THE PRODUCTION, PROCESSING AND HANDLING OF FOOD Radiation and Radiation... 21 Food and Drugs 3 2010-04-01 2009-04-01 true Sources of radiation used for inspection of food, for inspection of packaged food, and for controlling food processing. 179.21 Section 179.21 Food and...

  7. Process and device for the regulation of operating conditions of a catalytic cracking reactor using an ionizing radiation source

    Energy Technology Data Exchange (ETDEWEB)

    Beretta, A.; Boute, B.; Pontier, R.

    1991-05-31

    An ionizing radiation source and a radiation detector allow, through a radiation absorption technique, the measurement of the in-motion solid mean density, perpendicularly to the charge migration axis. The density measurement allows the measure and control of the solid quantity and/or the fluid characteristics and/or the hydrocarbon charge.

  8. Recycling of laser and plasma radiation energy for enhancement of extreme ultraviolet sources for nanolithography

    Science.gov (United States)

    Sizyuk, V.; Sizyuk, T.; Hassanein, A.; Johnson, K.

    2018-01-01

    We have developed comprehensive integrated models for detailed simulation of laser-produced plasma (LPP) and laser/target interaction, with potential recycling of the escaping laser and out-of-band plasma radiation. Recycling, i.e., returning the escaping laser and plasma radiation to the extreme ultraviolet (EUV) generation region using retroreflective mirrors, has the potential of increasing the EUV conversion efficiency (CE) by up to 60% according to our simulations. This would result in significantly reduced power consumption and/or increased EUV output. Based on our recently developed models, our High Energy Interaction with General Heterogeneous Target Systems (HEIGHTS) computer simulation package was upgraded for LPP devices to include various radiation recycling regimes and to estimate the potential CE enhancement. The upgraded HEIGHTS was used to study recycling of both laser and plasma-generated radiation and to predict possible gains in conversion efficiency compared to no-recycling LPP devices when using droplets of tin target. We considered three versions of the LPP system including a single CO2 laser, a single Nd:YAG laser, and a dual-pulse device combining both laser systems. The gains in generating EUV energy were predicted and compared for these systems. Overall, laser and radiation energy recycling showed the potential for significant enhancement in source efficiency of up to 60% for the dual-pulse system. Significantly higher CE gains might be possible with optimization of the pre-pulse and main pulse parameters and source size.

  9. Impact of the Metal Adhesion Layer on the Radiation Power of Plasmonic Photoconductive Terahertz Sources

    Science.gov (United States)

    Turan, Deniz; Corzo-Garcia, Sofia Carolina; Yardimci, Nezih Tolga; Castro-Camus, Enrique; Jarrahi, Mona

    2017-08-01

    The use of plasmonic contact electrodes in a photoconductive terahertz source offers high optical-to-terahertz conversion efficiencies. The high efficiency is because plasmonic contact electrodes concentrate a large portion of the incident optical pump beam in close proximity to the contact electrodes. By reducing the average transport path length of the photo-generated carriers from the contact electrodes, a larger number of the photocarriers drift to the terahertz radiating elements of the photoconductive source within a sub-picosecond time scale. Therefore, higher terahertz radiation power levels are achieved compared to a similar photoconductive source without plasmonic contact electrodes. Au is a preferred metal for plasmonic contact electrodes because of the strong plasmonic enhancement factors it offers at near-infrared optical wavelengths. However, it requires an adhesion layer to stick well to most III-V semiconductor substrates used in photoconductive terahertz sources. In this paper, we analyze the impact of the Au adhesion layer on the performance of plasmonic photoconductive sources fabricated on a GaAs substrate. Our analysis suggests that Cr is the most promising adhesion layer for plasmonic contact electrodes. We show that the use of a Cr adhesion layer instead of Ti, which is used in previously demonstrated plasmonic photoconductive sources, offers up to an 80% enhancement in the generated terahertz powers. We report record-high terahertz power emissions of up to 6.7 mW from plasmonic photoconductive sources with Cr/Au contacts.

  10. Impact of the Metal Adhesion Layer on the Radiation Power of Plasmonic Photoconductive Terahertz Sources

    Science.gov (United States)

    Turan, Deniz; Corzo-Garcia, Sofia Carolina; Yardimci, Nezih Tolga; Castro-Camus, Enrique; Jarrahi, Mona

    2017-12-01

    The use of plasmonic contact electrodes in a photoconductive terahertz source offers high optical-to-terahertz conversion efficiencies. The high efficiency is because plasmonic contact electrodes concentrate a large portion of the incident optical pump beam in close proximity to the contact electrodes. By reducing the average transport path length of the photo-generated carriers from the contact electrodes, a larger number of the photocarriers drift to the terahertz radiating elements of the photoconductive source within a sub-picosecond time scale. Therefore, higher terahertz radiation power levels are achieved compared to a similar photoconductive source without plasmonic contact electrodes. Au is a preferred metal for plasmonic contact electrodes because of the strong plasmonic enhancement factors it offers at near-infrared optical wavelengths. However, it requires an adhesion layer to stick well to most III-V semiconductor substrates used in photoconductive terahertz sources. In this paper, we analyze the impact of the Au adhesion layer on the performance of plasmonic photoconductive sources fabricated on a GaAs substrate. Our analysis suggests that Cr is the most promising adhesion layer for plasmonic contact electrodes. We show that the use of a Cr adhesion layer instead of Ti, which is used in previously demonstrated plasmonic photoconductive sources, offers up to an 80% enhancement in the generated terahertz powers. We report record-high terahertz power emissions of up to 6.7 mW from plasmonic photoconductive sources with Cr/Au contacts.

  11. X-radiation damage of hydrated lecithin membranes detected by real-time X-ray diffraction using wiggler-enhanced synchrotron radiation as the ionizing radiation source

    Science.gov (United States)

    Caffrey, Martin

    1984-05-01

    Radiation damage of hydrated lecithin membranes brought about by exposure to wiggler-derived synchrotron radiation at 8.3 keV (1.5 Å) is reported. Considerable damage was observed with exposures under 1 h at an incident flux density of 3 × 10 10 photon s -1 mm -2, corresponding to a cumulative radiation dose of ≦10 MRad. Damage was so dramatic as to be initially observed while making real-time X-ray diffraction measurements on the sample. The damaging effects of 8.3 keV X-rays on dispersions of dipalmitoyllecithin and lecithin derived from hen egg yolk are as follows: (1) marked changes were noted in the X-ray diffraction behaviour, indicating disruption of membrane stacking. (2) Chemical breakdown of lecithin was observed. (3) The X-ray beam visibly damaged the sample and changed the appearance of the lipid dispersion, when viewed under the light microscope. Considering the importance of X-ray diffraction as a structural probe and the anticipated use of synchrotron radiation in studies involving membranes, the problem of radiation damage must be duly recognized. Furthermore, since dipalmitoyllecithin, the major lipid used in the present study, is a relatively stable compound, it is not unreasonable to expect that X-ray damage may be a problem with other less stable biological and non-biological materials. These results serve to emphasize that whenever a high intensity X-ray source is used, radiation damage can be a problem and that the sensitivity of the sample must always be evaluated under the conditions of measurement.

  12. A critical experimental test of synchrotron radiation theory with 3rd generation light source

    Energy Technology Data Exchange (ETDEWEB)

    Geloni, Gianluca [European XFEL GmbH, Hamburg (Germany); Kocharyan, Vitali; Saldin, Evgeni [Deutsches Elektronen-Synchrotron (DESY), Hamburg (Germany)

    2016-05-15

    A recent ''beam splitting'' experiment at LCLS apparently demonstrated that after a microbunched electron beam is kicked on a large angle compared to the divergence of the FEL radiation, the microbunching wave front is readjusted along the new direction of motion of the kicked beam. Therefore, coherent radiation from an undulator placed after the kicker is emitted along the kicked direction without suppression. This strong emission of coherent undulator radiation in the kicked direction cannot be explained in the framework of conventional synchrotron radiation theory. In a previous paper we explained this puzzle. We demonstrated that, in accelerator physics, the coupling of fields and particles is based, on the one hand, on the use of results from particle dynamics treated according to the absolute time convention and, on the other hand, on the use of Maxwell equations treated according to the standard (Einstein) synchronization convention. Here lies the misconception which led to the strong qualitative disagreement between theory and experiment. After the ''beam splitting'' experiment at LCLS, it became clear that the conventional theory of synchrotron radiation cannot ensure the correct description of coherent and spontaneous emission from a kicked electron beam, nor the emission from a beam with finite angular divergence, in an undulator or a bending magnet. However, this result requires further experimental confirmation. In this publication we propose an uncomplicated and inexpensive experiment to test synchrotron radiation theory at 3rd generation light sources.

  13. Simulation of positron energy distributions from a hybrid positron source based on channeling radiation

    Energy Technology Data Exchange (ETDEWEB)

    Azadegan, B., E-mail: azadegan@hsu.ac.ir; Mahdipour, A., E-mail: Ali.mahdipour88@yahoo.com

    2013-12-01

    Positron energy distributions of a non-conventional positron source which is based on the generation of channeling radiation by relativistic electrons channeled along different crystallographic planes and axes of Si, C, Ge and W single crystals and the subsequent conversion of radiation into e{sup +}e{sup −}-pairs in an amorphous tungsten target have been simulated. The photon spectra of channeling radiation were calculated using the Doyle–Turner approximation for the continuum potentials of the crystallographic planes and axes considered. The classical equations of motion for channeled electrons have been solved in order to obtain the particle trajectories, velocities and accelerations. Applying classical electrodynamics, spectral-angular distributions of channeling radiation are calculated and their dependence on the incidence angle of the electrons is investigated. The calculation of channeling radiation was carried out using our developed Mathematica codes whereas the conversion of radiation into e{sup +}e{sup −}-pairs and the energy distributions of the positrons have been simulated by means of the GEANT4 package.

  14. Definition of loss-of-coolant accident radiation source. [PWR; BWR

    Energy Technology Data Exchange (ETDEWEB)

    1978-02-01

    Meaningful qualification testing of nuclear reactor components requires a knowledge of the radiation fields expected in a loss-of-coolant accident (LOCA). The overall objective of this program is to define the LOCA source terms and compare these with the output of various simulators employed for radiation qualification testing. The basis for comparison will be the energy deposition in a model reactor component. The results of the calculations are presented and some interpretation of the results given. The energy release rates and spectra were validated by comparison with other calculations using different codes since experimental data appropriate to these calculations do not exist.

  15. A Self-Assessment of the Effectiveness to Control Radiation Sources in Sierra Leone

    Energy Technology Data Exchange (ETDEWEB)

    Bun-Tejan, Umaru Remilekun [KAIST, Daejeon (Korea, Republic of); Lee, Byung Soo [Korea Institute of Nuclear Safety, Daejeon (Korea, Republic of)

    2016-10-15

    There is an urgent need to effectively control sources of ionizing radiation. Sources of ionizing radiation pose serious occupational, public health, and environmental consequences, if not properly controlled. The government of Sierra Leone knows the importance of controlling these sources of ionizing radiation and of establishing an independent Nuclear Safety Infrastructure. Sierra Leone has no nuclear facilities but, it is rapidly developing its infrastructure in order to obtain nuclear technology. However, the regulatory effectiveness in controlling radiation risk is essential for the International Atomic Energy Agency to allow the transfer of nuclear technology. For this reason, this study will evaluate the status of the regulatory authority in Sierra Leone to control radiation risk. The International Atomic Energy Agency (IAEA) review mission to Sierra Leone found that the RPBA did not give sufficient enforcement powers to the Board Secretariat. The research evaluated the status of the regulatory authority of Sierra Leone. The status of the regulatory authority was evaluated against several parameters including management systems, regulatory processes, authorization, inspection, and enforcement. The ability to effectively control ionizing radiation sources depends on the status of the regulatory body. The Integrated Regulatory Review Service Report on Sierra Leone led us to infer that there is a need for the regulatory authority to rapidly improve its ability to control ionizing radiation sources in the country. The findings however, revealed that the overall strengths of the regulatory body in Sierra Leone slightly outnumber the weaknesses. Management systems have a ratio of 0.85:1 of strengths to weaknesses. This ratio makes management systems the weakest parameter evaluated. Thus there is need for stronger collaboration between management staff. The Regulatory processes have a ratio of 1.3:1, authorizations have a ratio of 4.3:1, inspections have ratio of 2

  16. Magnetically Actuated Seal Project

    Data.gov (United States)

    National Aeronautics and Space Administration — FTT proposes development of a magnetically actuated dynamic seal. Dynamic seals are used throughout the turbopump in high-performance, pump-fed, liquid rocket...

  17. Magnetically Actuated Seal

    Science.gov (United States)

    Pinera, Alex

    2013-01-01

    This invention is a magnetically actuated seal in which either a single electromagnet, or multiple electromagnets, are used to control the seal's position. This system can either be an open/ close type of system or an actively controlled system.

  18. Saturn Neutron Exosphere as Source for Inner and Innermost Radiation Belts

    Science.gov (United States)

    Cooper, John; Lipatov, Alexander; Sittler, Edward; Sturner, Steven

    2011-01-01

    Energetic proton and electron measurements by the ongoing Cassini orbiter mission are expanding our knowledge of the highest energy components of the Saturn magnetosphere in the inner radiation belt region after the initial discoveries of these belts by the Pioneer 11 and Voyager 2 missions. Saturn has a neutron exosphere that extends throughout the magnetosphere from the cosmic ray albedo neutron source at the planetary main rings and atmosphere. The neutrons emitted from these sources at energies respectively above 4 and 8 eV escape the Saturn system, while those at lower energies are gravitationally bound. The neutrons undergo beta decay in average times of about 1000 seconds to provide distributed sources of protons and electrons throughout Saturn's magnetosphere with highest injection rates close to the Saturn and ring sources. The competing radiation belt source for energetic electrons is rapid inward diffusion and acceleration of electrons from the middle magnetosphere and beyond. Minimal losses during diffusive transport across the moon orbits, e.g. of Mimas and Enceladus, and local time asymmetries in electron intensity, suggest that drift resonance effects preferentially boost the diffusion rates of electrons from both sources. Energy dependences of longitudinal gradient-curvature drift speeds relative to the icy moons are likely responsible for hemispheric differences (e.g., Mimas, Tethys) in composition and thermal properties as at least partly produced by radiolytic processes. A continuing mystery is the similar radial profiles of lower energy (belt region. Either the source of these lower energy protons is also neutron decay, but perhaps alternatively from atmospheric albedo, or else all protons from diverse distributed sources are similarly affected by losses at the moon' orbits, e.g. because the proton diffusion rates are extremely low. Enceladus cryovolcanism, and radiolytic processing elsewhere on the icy moon and ring surfaces, are additional

  19. Impedance loading and radiation of finite aperture multipole sources in fluid filled boreholes

    Science.gov (United States)

    Geerits, Tim W.; Kranz, Burkhard

    2017-04-01

    In the exploration of oil and gas finite aperture multipole borehole acoustic sources are commonly used to excite borehole modes in a fluid-filled borehole surrounded by a (poro-) elastic formation. Due to the mutual interaction of the constituent sources and their immediate proximity to the formation it has been unclear how and to what extent these effects influence radiator performance. We present a theory, based on the equivalent surface source formulation for fluid-solid systems that incorporates these 'loading' effects and allows for swift computation of the multipole source dimensionless impedance, the associated radiator motion and the resulting radiated wave field in borehole fluid and formation. Dimensionless impedance results are verified through a comparison with finite element modeling results in the cases of a logging while drilling tool submersed in an unbounded fluid and a logging while drilling tool submersed in a fluid filled borehole surrounded by a fast and a slow formation. In all these cases we consider a monopole, dipole and quadrupole excitation, as these cases are relevant to many borehole acoustic applications. Overall, we obtain a very good agreement.

  20. Nonuniformity correction of infrared cameras by reading radiance temperatures with a spatially nonhomogeneous radiation source

    Science.gov (United States)

    Gutschwager, Berndt; Hollandt, Jörg

    2017-01-01

    We present a novel method of nonuniformity correction (NUC) of infrared cameras and focal plane arrays (FPA) in a wide optical spectral range by reading radiance temperatures and by applying a radiation source with an unknown and spatially nonhomogeneous radiance temperature distribution. The benefit of this novel method is that it works with the display and the calculation of radiance temperatures, it can be applied to radiation sources of arbitrary spatial radiance temperature distribution, and it only requires sufficient temporal stability of this distribution during the measurement process. In contrast to this method, an initially presented method described the calculation of NUC correction with the reading of monitored radiance values. Both methods are based on the recording of several (at least three) images of a radiation source and a purposeful row- and line-shift of these sequent images in relation to the first primary image. The mathematical procedure is explained in detail. Its numerical verification with a source of a predefined nonhomogeneous radiance temperature distribution and a thermal imager of a predefined nonuniform FPA responsivity is presented.

  1. Development of sup 1 sup 9 sup 2 Ir radiation sources for intravascular irradiation

    CERN Document Server

    Kogure, H; Iwamoto, S; Iwata, K; Kawauchi, Y; Nagata, Y; Sorita, T; Suzuki, K

    2003-01-01

    Intravascular brachytherapy is a novel therapy for preventing the restenosis of coronary artery by use of low-dose irradiation. JAERI and Kyoto University have been developing sup 1 sup 9 sup 2 Ir radiation sources by the cooperative research project entitled as 'The research on safety and effectiveness of the intravascular brachytherapy for preventing restenosis of the coronary artery disease' since 1998. The radiation source was introduced into the stenosis through a catheter (a guide-tube to insert directly into vascular) to irradiate the diseased part. Ten sup 1 sup 9 sup 2 Ir seed sources (phi 0.4 mm x 2.5 mm) were positioned between nylon spacers (phi 0.3 mm x 1.0 mm) in a flexible covering tube and the tube was plugged with a core-wire; the tube was shrunk to fix the inside materials and the size is 0.46 mm in diameter and 3 m in length. The physically optimal design was determined to insert the radiation source easily into vascular and to get the dose uniformity in the diseased part. The production me...

  2. A Study on the Radiation Source Effect to the Radiation Shielding Analysis for a Spent-Fuel Cask Design with Burnup-Credit

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Soon Young; Kim, Kyung O [RADCORE Co., Ltd., Daejeon (Korea, Republic of); Ko, Jae Hoon; Lee, Gang Gu [Korea Nuclear Engineering and Service Corp., Daejeon (Korea, Republic of); Kim, Tae Man; Yoon, Jeong Hyun [Korea Raioactive waste Management Corp., Daejeon (Korea, Republic of)

    2011-06-15

    The radiation shielding analysis for a Burnup-credit (BUC) cask designed under the management of Korea Radioactive Waste Management Corporation (KRMC) was performed to examine the contribution of each radiation source affecting dose rate distribution around the cask. Various radiation sources, which contain neutron and gamma-ray sources placed in active fuel region and the activation source, and imaginary nuclear fuel were all considered in the MCNP calculation model to realistically simulate the actual situations. It was found that the maximum external and surface dose rates of the spent fuel cask were satisfied with the domestic standards both in normal and accident conditions. In normal condition, the radiation dose rate distribution around the cask was mainly influenced by activation source (60 Co radioisotope); in another case, the neutron emitted in active fuel region contributed about 90% to external dose rate at 1m distance from side surface of the cask. Besides, the contribution level of activation source was dramatically increased to the dose rates in top and bottom regions of the cask. From this study, it was recognized that the detailed investigation on the radiation sources should be performed conservatively and accurately in the process of radiation shielding analysis for a BUC cask.

  3. The regulatory control over radiation sources: the Brazilian experience and some lessons learned from industrial applications

    Energy Technology Data Exchange (ETDEWEB)

    Costa, E.L.C.; Gomes, J.D.R.L.; Gomes, R.S.; Costa, M.L.L.; Thomé, Z.D., E-mail: evaldo@cnen.gov.br, E-mail: jlopes@cnen.gov.br, E-mail: rogeriog@cnen.gov.br, E-mail: mara@cnen.gov.br, E-mail: zielithome@gmail.com [Comissao Nacional de Energia Nuclear (CNEN), Rio de Janeiro, RJ (Brazil). Diretoria de Radioproteção e Segurança Nuclear; Instituto Militar de Engenharia (IME), Rio de Janeiro, RJ (Brazil). Seção de Engenharia Nuclear

    2017-11-01

    This study gives an overview of the activities of the National Commission of Nuclear Energy (CNEN), as the Brazilian nuclear regulatory authority. These activities are described, especially those related to management of orphan sources and radioactive material in scrap metal considering the actions already put into place by CNEN during the licensing and controlling of radioactive sources in the industry and other facilities. In Brazil, there is not yet an effective system for controlling the scrap metal and recycling industry, thus a coordinated approach to achieve a harmonized and effective response with the involvement of third parties is needed, especially the metal industries and ores facilities. These practices call for stringent regulatory control, in order to reduce the occurrence of orphan sources, and consequently, radioactive material appearing in scrap metal. Some challenges of managing the national radiation sources register systems will be discussed, in order to cover effectively all the radiation source history (in a 'from the cradle to the grave' basis), and the dynamic maintenance and update of these data. The main industrial applications considered in this work are those dealing with constant movement of sources all over the country, with geographical issues to be considered in the managing and controlling actions, such as gammagraphy and well-logging. This study aims to identify and promote good practices to prevent inadvertent diversion of radioactive material, taking into account existing international recommendations and some lessons learned in national level. (author)

  4. Gravitational Radiation from Post-Newtonian Sources and Inspiralling Compact Binaries

    Directory of Open Access Journals (Sweden)

    Blanchet Luc

    2006-06-01

    Full Text Available The article reviews the current status of a theoretical approach to the problem of the emission of gravitational waves by isolated systems in the context of general relativity. Part A of the article deals with general post-Newtonian sources. The exterior field of the source is investigated by means of a combination of analytic post-Minkowskian and multipolar approximations. The physical observables in the far-zone of the source are described by a specific set of radiative multipole moments. By matching the exterior solution to the metric of the post-Newtonian source in the near-zone we obtain the explicit expressions of the source multipole moments. The relationships between the radiative and source moments involve many non-linear multipole interactions, among them those associated with the tails (and tails-of-tails of gravitational waves. Part B of the article is devoted to the application to compact binary systems. We present the equations of binary motion, and the associated Lagrangian and Hamiltonian, at the third post-Newtonian (3PN order beyond the Newtonian acceleration. The gravitational-wave energy flux, taking consistently into account the relativistic corrections in the binary moments as well as the various tail effects, is derived through 3.5PN order with respect to the quadrupole formalism. The binary's orbital phase, whose prior knowledge is crucial for searching and analyzing the signals from inspiralling compact binaries, is deduced from an energy balance argument.

  5. Skew resisting hydrodynamic seal

    Science.gov (United States)

    Conroy, William T.; Dietle, Lannie L.; Gobeli, Jeffrey D.; Kalsi, Manmohan S.

    2001-01-01

    A novel hydrodynamically lubricated compression type rotary seal that is suitable for lubricant retention and environmental exclusion. Particularly, the seal geometry ensures constraint of a hydrodynamic seal in a manner preventing skew-induced wear and provides adequate room within the seal gland to accommodate thermal expansion. The seal accommodates large as-manufactured variations in the coefficient of thermal expansion of the sealing material, provides a relatively stiff integral spring effect to minimize pressure-induced shuttling of the seal within the gland, and also maintains interfacial contact pressure within the dynamic sealing interface in an optimum range for efficient hydrodynamic lubrication and environment exclusion. The seal geometry also provides for complete support about the circumference of the seal to receive environmental pressure, as compared the interrupted character of seal support set forth in U.S. Pat. Nos. 5,873,576 and 6,036,192 and provides a hydrodynamic seal which is suitable for use with non-Newtonian lubricants.

  6. Seals in motion

    NARCIS (Netherlands)

    Brasseur, Sophie Marie Jacqueline Michelle

    2017-01-01

    The harbour seal Phoca vitulina and the grey seal Halichoerus grypus have been inhabitants of the Wadden Sea since millennia. Prehistoric findings indicate the presence of both species around 5000 BC. This changed dramatically in the mid Middle-Ages as around 1500 AC, the grey seal disappeared from

  7. Advisory Committee on human radiation experiments. Supplemental Volume 2a, Sources and documentation appendices. Final report

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1995-01-01

    This large document provides a catalog of the location of large numbers of reports pertaining to the charge of the Presidential Advisory Committee on Human Radiation Research and is arranged as a series of appendices. Titles of the appendices are Appendix A- Records at the Washington National Records Center Reviewed in Whole or Part by DoD Personnel or Advisory Committee Staff; Appendix B- Brief Descriptions of Records Accessions in the Advisory Committee on Human Radiation Experiments (ACHRE) Research Document Collection; Appendix C- Bibliography of Secondary Sources Used by ACHRE; Appendix D- Brief Descriptions of Human Radiation Experiments Identified by ACHRE, and Indexes; Appendix E- Documents Cited in the ACHRE Final Report and other Separately Described Materials from the ACHRE Document Collection; Appendix F- Schedule of Advisory Committee Meetings and Meeting Documentation; and Appendix G- Technology Note.

  8. Radiation Tolerance Qualification Tests of the Final Source Interface Unit for the ALICE Experiment

    CERN Document Server

    Dénes, E; Futó, E; Kerék, A; Kiss, T; Molnár, J; Novák, D; Soós, C; Tölyhi, T; Van de Vyvre, P

    2007-01-01

    The ALICE Detector Data Link (DDL) is a high-speed optical link designed to interface the readout electronics of ALICE sub-detectors to the DAQ computers. The Source Interface Unit (SIU) of the DDL will operate in radiation environment. Previous tests showed that a configuration loss of SRAM-based FPGA devices may happen and the frequency of undetected data errors in the FPGA user memory area is also not acceptable. Therefore, we redesigned the SIU card using another FPGA based on flash technology. In order to detect bit errors in the user memory we added parity check logic to the design. The new SIU has been extensively tested using neutron and proton irradiation to verify its radiation tolerance. In this paper we summarize the design changes, introduce the final design, and the results of the radiation tolerance measurements on the final card.

  9. A reliable sealing method for microbatteries

    Science.gov (United States)

    Wang, Yuxing; Cartmell, Samuel; Li, Qiuyan; Xiao, Jie; Li, Huidong; Deng, Zhiqun Daniel; Zhang, Ji-Guang

    2017-02-01

    As electronic devices continue to become smaller, their energy sources (i.e., batteries) also need to be smaller. Typically, energy densities of batteries decrease as the battery size decreases due to the relative increase of parasitic weight such as packaging materials. In addition, the sealing methods in conventional batteries are difficult to apply to microbatteries. In this work, we developed a facile sealing method for microbatteries. The method employs a dual-sealing concept: a first rubber barrier temporally confines the organic electrolytes and a second adhesive barrier forms a hermetic seal with the battery case. With this innovative sealing approach, excellent shelf life and operation life of the batteries have been demonstrated. A minimal amount of packing materials is employed resulting in high energy densities.

  10. Application of high-temperature superconducting permanent magnets to synchrotron radiation sources

    Directory of Open Access Journals (Sweden)

    Takashi Tanaka

    2004-09-01

    Full Text Available A simple scheme for field enhancement in synchrotron radiation sources such as undulators and wigglers is proposed, which is based on the fundamental nature of the superconducting loop where the magnetic flux is preserved. A superconductor ring placed to enclose the magnetic pole works as a kind of permanent magnet. The magnetization is performed by electromagnetic induction brought by the opening movement of the magnetic gap. Since neither additional external power supplies nor current leads are necessary, high-temperature bulk superconductors can easily be implemented in this scheme. Calculations to check the effectiveness of the new concept show that the critical current density of the superconductor is crucial to the performance of the synchrotron radiation sources based on this concept. Experiments were performed to verify the principle of the proposed scheme, which gave promising results to strongly support it.

  11. Ultraviolet-B radiation enhancement in dielectric barrier discharge based xenon chloride exciplex source by air

    Energy Technology Data Exchange (ETDEWEB)

    Gulati, P., E-mail: pgulati1512@gmail.com [CSIR-Central Electronics Engineering Research Institute (CSIR-CEERI), Pilani, Rajasthan-333031 (India); Department of Physics, Banasthali University, P.O. Banasthali Vidyapith, Rajasthan 304022 (India); Prakash, R.; Pal, U. N.; Kumar, M. [CSIR-Central Electronics Engineering Research Institute (CSIR-CEERI), Pilani, Rajasthan-333031 (India); Vyas, V. [Department of Physics, Banasthali University, P.O. Banasthali Vidyapith, Rajasthan 304022 (India)

    2014-07-07

    A single barrier dielectric barrier discharge tube of quartz with multi-strip Titanium-Gold (Ti-Au) coatings have been developed and utilized for ultraviolet-B (UV-B) radiation production peaking at wavelength 308 nm. The observed radiation at this wavelength has been examined for the mixtures of the Xenon together with chlorine and air admixtures. The gas mixture composition, chlorine gas content, total gas pressure, and air pressure dependency of the UV intensity, has been analyzed. It is found that the larger concentration of Cl{sub 2} deteriorates the performance of the developed source and around 2% Cl{sub 2} in this source produced optimum results. Furthermore, an addition of air in the xenon and chlorine working gas environment leads to achieve same intensity of UV-B light but at lower working gas pressure where significant amount of gas is air.

  12. Effective extreme ultraviolet radiation source based on laser-produced plasma in supersonic xenon jet

    Science.gov (United States)

    Bobashev, S. V.; Domracheva, I. V.; Petrenko, M. V.; Tumakaev, G. K.; Stepanova, Z. A.

    2007-04-01

    Development of highly effective debris free EUV (extreme ultraviolet) radiation source is an actual problem today. Experimental results on EUV output from the source based on laser-produced plasma in supersonic Xe jet have been obtained. The conversion efficiency is 0.08% at a wavelength of 13.5 nm (Δλ = 0.35 nm, 2π sterrad). The methods of optimization of gas-jet converter have been determined. Measurements of EUV radiation energy dependence on the laser energy and the target material (solid-state Cu, Mo, W, Ta and supersonic Xe jet) have been made. The conversion efficiency of laser-produced plasma (CELPP) has been determined and the experimental values have been obtained for different materials of the target.

  13. Experimental verification of isotropic radiation from a coherent dipole source via electric-field-driven LC resonator metamaterials.

    Science.gov (United States)

    Tichit, Paul-Henri; Burokur, Shah Nawaz; Qiu, Cheng-Wei; de Lustrac, André

    2013-09-27

    It has long been conjectured that isotropic radiation by a simple coherent source is impossible due to changes in polarization. Though hypothetical, the isotropic source is usually taken as the reference for determining a radiator's gain and directivity. Here, we demonstrate both theoretically and experimentally that an isotropic radiator can be made of a simple and finite source surrounded by electric-field-driven LC resonator metamaterials designed by space manipulation. As a proof-of-concept demonstration, we show the first isotropic source with omnidirectional radiation from a dipole source (applicable to all distributed sources), which can open up several possibilities in axion electrodynamics, optical illusion, novel transformation-optic devices, wireless communication, and antenna engineering. Owing to the electric- field-driven LC resonator realization scheme, this principle can be readily applied to higher frequency regimes where magnetism is usually not present.

  14. Physical infeasibility of geodesic dissipative dust as a source of gravitational radiation

    CERN Document Server

    Herrera, L; Ospino, J

    2015-01-01

    Using a framework based on the 1+3 formalism, we show that a source represented by a geodesic, dissipative, rotational dust, endowed with axial and reflection symmetry, violates regularity conditions at the center of the fluid distribution, unless the dissipative flux vanishes. In this latter case the vorticity also must vanish, and the resulting spacetime is Friedman--Robertson--Walker (FRW). Therefore it does not produce gravitational radiation.

  15. Are Energetic Electrons in the Solar Wind the Source of the Outer Radiation Belt?

    OpenAIRE

    Li, Xinlin; Baker, D. N.; Temerin, M.; Larson, D.; Lin, R. P.; Reeves, G. D.; Looper, M.; Kanekal, S. G.; Mewaldt, R. A.

    1997-01-01

    Using data from WIND, SAMPEX (Solar Anomalous, and Magnetospheric Particle Explorer), and the Los Alamos National Laboratory (LANL) sensors onboard geostationary satellites, we investigate the correlation of energetic electrons in the 20–200 keV range in the solar wind and of high speed solar wind streams with relativistic electrons in the magnetosphere to determine whether energetic electrons in the solar wind are the source of the outer relativistic electron radiation belt. Though there is ...

  16. Situational awareness of hazards: Validation of multi-source radiation measurements

    Science.gov (United States)

    Hultquist, C.; Cervone, G.

    2016-12-01

    Citizen-led movements producing scientific hazard data during disasters are increasingly common. After the Japanese earthquake-triggered tsunami in 2011, and the resulting radioactive releases at the damaged Fukushima Daiichi nuclear power plants, citizens monitored on-ground levels of radiation with innovative mobile devices built from off-the-shelf components. To date, the citizen-led SAFECAST project has recorded 50 million radiation measurements worldwide, with the majority of these measurements from Japan. The analysis of data which are multi-dimensional, not vetted, and provided from multiple devices presents big data challenges due to their volume, velocity, variety, and veracity. While the SAFECAST project produced massive open-source radiation measurements at specific coordinates and times, the reliability and validity of the overall data have not yet been assessed. The nuclear disaster provides a case for assessing the SAFECAST data with official aerial remote sensing radiation data jointly collected by the governments of the United States and Japan. A spatial and statistical assessment of SAFECAST requires several preprocessing steps. First, SAFECAST ionized radiation sensors collected data using different units of measure than the government data, and they had to be converted. Secondly, the normally occurring radiation and decay rates of Cesium from deposition surveys were used to properly compare measurements in space and time. Finally, the GPS located points were selected within overlapping extents at multiple spatial resolutions. Quantitative measures were used to assess the similarity and differences in the observed measurements. Radiation measurements from the same geographic extents show similar spatial variations and statistically significant correlations. The results suggest that actionable scientific data for disasters and emergencies can be inferred from non-traditional and not vetted data generated through citizen science projects. This

  17. Low Cost, Durable Seal

    Energy Technology Data Exchange (ETDEWEB)

    Roberts, George; Parsons, Jason; Friedman, Jake

    2010-12-17

    Seal durability is critical to achieving the 2010 DOE operational life goals for both stationary and transportation PEM fuel cell stacks. The seal material must be chemically and mechanically stable in an environment consisting of aggressive operating temperatures, humidified gases, and acidic membranes. The seal must also be producible at low cost. Currentlyused seal materials do not meet all these requirements. This project developed and demonstrated a high consistency hydrocarbon rubber seal material that was able to meet the DOE technical and cost targets. Significant emphasis was placed on characterization of the material and full scale molding demonstrations.

  18. Debris and radiation-induced damage effects on EUV nanolithography source collector mirror optics performance.

    Energy Technology Data Exchange (ETDEWEB)

    Allain, J. P.; Nieto, M.; Hendricks, M.; Harilal, S. S.; Hassanein, A.; Mathematics and Computer Science

    2007-01-01

    Exposure of collector mirrors facing the hot, dense pinch plasma in plasma-based EUV light sources to debris (fast ions, neutrals, off-band radiation, droplets) remains one of the highest critical issues of source component lifetime and commercial feasibility of nanolithography at 13.5-nm. Typical radiators used at 13.5-nm include Xe and Sn. Fast particles emerging from the pinch region of the lamp are known to induce serious damage to nearby collector mirrors. Candidate collector configurations include either multi-layer mirrors (MLM) or single-layer mirrors (SLM) used at grazing incidence. Studies at Argonne have focused on understanding the underlying mechanisms that hinder collector mirror performance at 13.5-nm under fast Sn or Xe exposure. This is possible by a new state-of-the-art in-situ EUV reflectometry system that measures real time relative EUV reflectivity (15-degree incidence and 13.5-nm) variation during fast particle exposure. Intense EUV light and off-band radiation is also known to contribute to mirror damage. For example offband radiation can couple to the mirror and induce heating affecting the mirror's surface properties. In addition, intense EUV light can partially photo-ionize background gas (e.g., Ar or He) used for mitigation in the source device. This can lead to local weakly ionized plasma creating a sheath and accelerating charged gas particles to the mirror surface and inducing sputtering. In this paper we study several aspects of debris and radiation-induced damage to candidate EUVL source collector optics materials. The first study concerns the use of IMD simulations to study the effect of surface roughness on EUV reflectivity. The second studies the effect of fast particles on MLM reflectivity at 13.5-nm. And lastly the third studies the effect of multiple energetic sources with thermal Sn on 13.5-nm reflectivity. These studies focus on conditions that simulate the EUVL source environment in a controlled way.

  19. Debris- and radiation-induced damage effects on EUV nanolithography source collector mirror optics performance

    Science.gov (United States)

    Allain, J. P.; Nieto, M.; Hendricks, M.; Harilal, S. S.; Hassanein, A.

    2007-05-01

    Exposure of collector mirrors facing the hot, dense pinch plasma in plasma-based EUV light sources to debris (fast ions, neutrals, off-band radiation, droplets) remains one of the highest critical issues of source component lifetime and commercial feasibility of nanolithography at 13.5-nm. Typical radiators used at 13.5-nm include Xe and Sn. Fast particles emerging from the pinch region of the lamp are known to induce serious damage to nearby collector mirrors. Candidate collector configurations include either multi-layer mirrors (MLM) or single-layer mirrors (SLM) used at grazing incidence. Studies at Argonne have focused on understanding the underlying mechanisms that hinder collector mirror performance at 13.5-nm under fast Sn or Xe exposure. This is possible by a new state-of-the-art in-situ EUV reflectometry system that measures real time relative EUV reflectivity (15-degree incidence and 13.5-nm) variation during fast particle exposure. Intense EUV light and off-band radiation is also known to contribute to mirror damage. For example offband radiation can couple to the mirror and induce heating affecting the mirror's surface properties. In addition, intense EUV light can partially photo-ionize background gas (e.g., Ar or He) used for mitigation in the source device. This can lead to local weakly ionized plasma creating a sheath and accelerating charged gas particles to the mirror surface and inducing sputtering. In this paper we study several aspects of debris and radiation-induced damage to candidate EUVL source collector optics materials. The first study concerns the use of IMD simulations to study the effect of surface roughness on EUV reflectivity. The second studies the effect of fast particles on MLM reflectivity at 13.5-nm. And lastly the third studies the effect of multiple energetic sources with thermal Sn on 13.5-nm reflectivity. These studies focus on conditions that simulate the EUVL source environment in a controlled way.

  20. Compact Z-pinch radiation source dedicated to broadband absorption measurements

    Directory of Open Access Journals (Sweden)

    Dunpin Hong

    2016-05-01

    Full Text Available In order to acquire a broadband absorption spectrum in a single shot, a compact radiation source was developed by using a Z-pinch type electric discharge. This paper presents the mechanical and electrical construction of the source, as well as its electrical and optical characteristics, including the intense continuum of radiation emitted by the source in the UV and visible spectral range. It also shows that the compactness of the source allows direct coupling with the probed medium, enabling broadband absorption measurement in the spectral range of 200–300 nm without use of an optical fiber which strongly attenuates the light in the short wavelength range. Concretely, thanks to this source, broadband spectral absorption of NO molecules around 210 nm and that of OH molecules around 310 nm were recorded in this direct coupling arrangement. Copper atom spectral absorption around 325 nm of the peripheral cold zones of an intense transient arc was also recorded.

  1. Radiation protection with consumer products containing gaseous tritium light sources; Strahlenschutz bei Konsumguetern mit Tritium-Gaslichtquellen

    Energy Technology Data Exchange (ETDEWEB)

    Rahders, Erio; Haeusler, Uwe [Bundesamt fuer Strahlenschutz, Berlin (Germany)

    2017-08-01

    Consumer products containing gaseous tritium light sources (GTLS) were examined with respect to their radiological safety potential regarding leak tightness or accidents. The maximum tritium leakage rate of 2.7 Bq/d determined from experimental testing is well below the criterion for leak tightness of sealed radioactive sources in DIN 25426-4. In order to investigate the incorporation of tritium due to contact with consumer products, 2 scenarios were reviewed; the correct use of a tritium watch and the accident scenario with a keyring.

  2. SURF III: A flexible synchrotron radiation source for radiometry and research

    Energy Technology Data Exchange (ETDEWEB)

    Arp, U., E-mail: uwe.arp@nist.gov [Synchrotron Ultraviolet Radiation Facility SURF III, National Institute of Standards and Technology, Gaithersburg, 100 Bureau Dr, MD 20899-8410 (United States); Clark, C.; Deng, L.; Faradzhev, N.; Farrell, A.; Furst, M.; Grantham, S.; Hagley, E.; Hill, S.; Lucatorto, T.; Shaw, P.-S.; Tarrio, C.; Vest, R. [Synchrotron Ultraviolet Radiation Facility SURF III, National Institute of Standards and Technology, Gaithersburg, 100 Bureau Dr, MD 20899-8410 (United States)

    2011-09-01

    The calculability of synchrotron radiation (SR) makes electron storage rings wonderful light sources for radiometry. The broadband nature of SR allows coverage of the entire spectral region from the X-ray to the far-infrared. Compact low-energy storage rings like the Synchrotron Ultraviolet Radiation Facility SURF III are perfect sources for radiometric applications, because the output spectrum can be custom-tailored to the user's needs: low current operations can simulate the solar spectrum, changes to the electron energy can address higher-order contributions of spectrometers and monochromators, and manipulation of the source size can increase the lifetime or change the radiation density. At large multi-user facilities these special operational conditions are generally not possible, since many users have to be satisfied simultaneously. At SURF III, NIST maintains one of the best SR-based infrared to soft X-ray calibration programs in the world: standard lamp calibrations, detector calibrations, and measurements of optical properties are routinely performed at SURF with great reliability and accuracy.

  3. Phylogenomics Reveals Three Sources of Adaptive Variation during a Rapid Radiation.

    Directory of Open Access Journals (Sweden)

    James B Pease

    2016-02-01

    Full Text Available Speciation events often occur in rapid bursts of diversification, but the ecological and genetic factors that promote these radiations are still much debated. Using whole transcriptomes from all 13 species in the ecologically and reproductively diverse wild tomato clade (Solanum sect. Lycopersicon, we infer the species phylogeny and patterns of genetic diversity in this group. Despite widespread phylogenetic discordance due to the sorting of ancestral variation, we date the origin of this radiation to approximately 2.5 million years ago and find evidence for at least three sources of adaptive genetic variation that fuel diversification. First, we detect introgression both historically between early-branching lineages and recently between individual populations, at specific loci whose functions indicate likely adaptive benefits. Second, we find evidence of lineage-specific de novo evolution for many genes, including loci involved in the production of red fruit color. Finally, using a "PhyloGWAS" approach, we detect environment-specific sorting of ancestral variation among populations that come from different species but share common environmental conditions. Estimated across the whole clade, small but substantial and approximately equal fractions of the euchromatic portion of the genome are inferred to contribute to each of these three sources of adaptive genetic variation. These results indicate that multiple genetic sources can promote rapid diversification and speciation in response to new ecological opportunity, in agreement with our emerging phylogenomic understanding of the complexity of both ancient and recent species radiations.

  4. Investigating the source of near-relativistic and relativistic electrons in Earth's inner radiation belt

    Science.gov (United States)

    Turner, D. L.; O'Brien, T. P.; Fennell, J. F.; Claudepierre, S. G.; Blake, J. B.; Jaynes, A. N.; Baker, D. N.; Kanekal, S.; Gkioulidou, M.; Henderson, M. G.; Reeves, G. D.

    2017-01-01

    Using observations from NASA's Van Allen Probes, we study the role of sudden particle enhancements at low L shells (SPELLS) as a source of inner radiation belt electrons. SPELLS events are characterized by electron intensity enhancements of approximately an order of magnitude or more in less than 1 day at L belt electrons under quiet/average conditions. During SPELLS events, the evolution of electron distributions reveals an enhancement of phase space density that can exceed 3 orders of magnitude in the slot region and continues into the inner radiation belt, which is evidence that these events are an important—and potentially dominant—source of inner belt electrons. Electron fluxes from September 2012 through February 2016 reveal that SPELLS occur frequently ( 2.5/month at 200 keV), but the number of observed events decreases exponentially with increasing electron energy for ≥100 keV. After SPELLS events, the slot region reforms due to slow energy-dependent decay over several day time scales, consistent with losses due to interactions with plasmaspheric hiss. Combined, these results indicate that the peaked phase space density distributions in the inner electron radiation belt result from an "on/off," geomagnetic-activity-dependent source from higher radial distances.

  5. Analysis of stray radiation produced by the advanced light source (1.9 GeV synchrotron radiation source) at Lawrence Berkeley Laboratory

    Energy Technology Data Exchange (ETDEWEB)

    Ajemian, Robert C. [Univ. of North Carolina, Chapel Hill, NC (United States). Dept. of Environmental Sciences and Engineering

    1995-01-01

    The yearly environmental dose equivalent likely to result at the closest site boundary from the Advanced Light Source was determined by generating multiple linear regressions. The independent variables comprised quantified accelerator operating parameters and measurements from synchronized, in-close (outside shielding prior to significant atmospheric scattering), state-of-the-art neutron remmeters and photon G-M tubes. Neutron regression models were more successful than photon models due to lower relative background radiation and redundant detectors at the site boundary. As expected, Storage Ring Beam Fill and Beam Crashes produced radiation at a higher rate than gradual Beam Decay; however, only the latter did not include zero in its 95% confidence interval. By summing for all three accelerator operating modes, a combined yearly DE of 4.3 mRem/yr with a 90% CI of (0.04-8.63) was obtained. These results fall below the DOE reporting level of 10 mRem/yr and suggest repeating the study with improved experimental conditions.

  6. Laser-plasma accelerator and femtosecond photon sources-based ultrafast radiation chemistry and biophysics

    Science.gov (United States)

    Gauduel, Y. A.

    2017-02-01

    The initial distribution of energy deposition triggered by the interaction of ionizing radiations (far UV and X rays, electron, proton and accelerated ions) with molecular targets or integrated biological systems is often decisive for the spatio-temporal behavior of radiation effects that take place on several orders of magnitude. This contribution deals with an interdisciplinary approach that concerns cutting-edge advances on primary radiation events, considering the potentialities of innovating strategies based on ultrafast laser science, from femtosecond photon sources to laser-driven relativistic particles acceleration. Recent advances of powerful TW laser sources (~ 1019 Wcm-2) and laser-plasma interactions providing ultrashort relativistic particle beams in the energy domain 2.5-150 MeV open exciting opportunities for the development of high-energy radiation femtochemistry (HERF). Early radiation damages being dependent on the survival probability of secondary electrons and radial distribution of short-lived radicals inside ionization clusters, a thorough knowledge of these processes involves the real-time probing of primary events in the temporal range 10-14-10-11 s. In the framework of a closed synergy between low-energy radiation femtochemistry (LERF) and the emerging domain of HERF, the paper focuses on early phenomena that occur in the prethermal regime of low-energy secondary electrons, considering very short-lived quantum effects in aqueous environments. A high dose-rate delivered by femtosecond electron beam (~ 1011-1013 Gy s-1) can be used to investigate early radiation processes in native ionization tracks, down to 10-12 s and 10-9 m. We explain how this breakthrough favours the innovating development of real-time nanodosimetry in biologically relevant environments and open new perspectives for spatio-temporal radiation biophysics. The emerging domain of HERF would provide guidance for understanding the specific bioeffects of ultrashort particle

  7. What views and uses of radiation sources in the 21st century?

    Science.gov (United States)

    Blix, H

    2001-04-01

    Considering that in 1899 neither biotechnology nor the electronic revolution were foreseen, some humility might be advisable when one looks into the crystal ball for the future role of radiation sources. In the past 50 years, nuclear medicine, nuclear weapons, and nuclear power have had a huge impact in the world. In the next 50 years, nuclear weapons may be phased out, nuclear power revived, and nuclear medicine may continue, especially for diagnostic purposes. Conflicts between great powers and blocks will no longer be about territorial or ideological domination but about trade, finance, information, and the environment and the weapons used will not be bombs but investments, credits, and control of information. Nuclear power-still based on fission-will be relaunched and get more uses, e.g., to propel ships, to produce heat for industry and for space heating, and perhaps to desalinate water. The public will be more at ease with radiation as it is better educated, as nuclear safety continuously improves and new types of nuclear power plants emerge, as waste sites fail to cause any problems, and as no other energy source is found to deliver so much energy at reasonable cost with negligible impact on climate and environment. One kilogram of oil corresponds to 4 kWh of electricity. One kilogram of uranium fuel corresponds to 50,000 kWh, and 1 kg of plutonium 6,000,000 kWh! In nuclear medicine, radiation may give way to other treatments as the understanding of cancer advances. On the other hand, the extreme ease with which sources of radiation can be identified is unmatched and likely to make them useful tools as tracers and markers in medicine-and other fields-for a long time. For certain uses--perhaps food irradiation--radiation sources, such as cobalt, may be replaced by accelerators which may be switched on and off at will. As more sources are used, registration and control of them must be made very effective around the whole world. Very high natural emissions of

  8. Sealing materials seals for arctic applications

    OpenAIRE

    Eichstaedt, Joanna Anna

    2016-01-01

    This thesis is about exploring the performance of rubber O-ring seals made of materials such as: ELAST-O-LION 101, base HNBR and HNBR 50 CB, under cold temperatures and compressions equal to 10% and 20%. Initially a test apparatus with cooling chamber was built to evaluate seal performance at different temperatures and contact pressures. This part of the project included building the environmental chamber in which the mechanical compression rig is located, as well as connecting the circulatin...

  9. Detection of seal contamination in heat-sealed food packaging based on active infrared thermography

    Science.gov (United States)

    D'huys, Karlien; Saeys, Wouter; De Ketelaere, Bart

    2015-05-01

    In the food industry packaging is often applied to protect the product from the environment, assuring quality and safety throughout shelf life if properly performed. Packaging quality depends on the material used and the closure (seal). The material is selected based on the specific needs of the food product to be wrapped. However, proper closure of the package is often harder to achieve. One problem possibly jeopardizing seal quality is the presence of food particles between the seal. Seal contamination can cause a decreased seal strength and thus an increased packaging failure risk. It can also trigger the formation of microchannels through which air and microorganisms can enter and spoil the enclosed food. Therefore, early detection and removal of seal-contaminated packages from the production chain is essential. In this work, a pulsed-type active thermography method using the heat of the sealing bars as an excitation source was studied for detecting seal contamination. The cooling profile of contaminated seals was recorded. The detection performance of four processing methods (based on a single frame, a fit of the cooling profile, pulsed phase thermography and a matched filter) was compared. High resolution digital images served as a reference to quantify contamination. The lowest detection limit (equivalent diameter of 0.63 mm) and the lowest processing time (0.42 s per sample) were obtained for the method based on a single frame. Presumably, practical limitations in the recording stage prevented the added value of active thermography to be fully reflected in this application.

  10. The Spectral Statistical Method for Determining the Location Parameters of a Dipole Source of Electromagnetic Radiation

    Science.gov (United States)

    Panyukov, A. V.; Bogushov, A. K.

    2016-09-01

    Using the measured horizontal and vertical components of the magnetic and electric fields, respectively, we solve the problem of determining the location of a dipole source of electromagnetic radiation, which is equivalent to the lightning discharge, at the specified point of an infinitely conducting plane. The proposed method, which is based on the analysis of the measured-signal spectra, allows one to develop many estimates of the source location, choose the final estimate on the basis of the results of analysis of the entire totality of these estimates, and, therefore, reach stability in determining the source location. The spectral method makes it possible to obtain more stable solutions at a lower computation cost compared with the previously developed parametric extremum method. The spectral-method algorithm can be naturally parallelized. The results of the analytical and numerical studies of the accuracy and stability of the proposed method are presented.

  11. Analysis and Measurements of Artificial Optical Radiation (AOR Emitted by Lighting Sources Found in Offices

    Directory of Open Access Journals (Sweden)

    Francesco Leccese

    2014-09-01

    Full Text Available In this paper the authors describe in detail the exposure limit values concerning artificial optical radiation due to the main incoherent light sources found in offices. In particular, for some examples of significant sources chosen as case studies, we discuss the results of in situ measurements of the exposure values using a broadband photoradiometer. By comparing the measurement results with the exposure limit values specified in the European legislation, the maximum exposure times for workers have been evaluated. From the analysis of the results it can be concluded that the lighting sources typically present in indoor workplaces under usual conditions of use, do not pose a health risks for workers. However, in the case of accidental exposure during work activities or exposure linked to maintenance activities (short exposure distance, values in excess of the limit values have been observed, with decidedly short maximum exposure times.

  12. Application and development of ion-source technology for radiation-effects testing of electronics

    Science.gov (United States)

    Kalvas, T.; Javanainen, A.; Kettunen, H.; Koivisto, H.; Tarvainen, O.; Virtanen, A.

    2017-09-01

    Studies of heavy-ion induced single event effect (SEE) on space electronics are necessary to verify the operation of the components in the harsh radiation environment. These studies are conducted by using high-energy heavy-ion beams to simulate the radiation effects in space. The ion beams are accelerated as so-called ion cocktails, containing several ion beam species with similar mass-to-charge ratio, covering a wide range of linear energy transfer (LET) values also present in space. The use of cocktails enables fast switching between beam species during testing. Production of these high-energy ion cocktails poses challenging requirements to the ion sources because in most laboratories reaching the necessary beam energies requires very high charge state ions. There are two main technologies producing these beams: The electron beam ion source EBIS and the electron cyclotron resonance ion source ECRIS. The EBIS is most suitable for pulsed accelerators, while ECRIS is most suitable for use with cyclotrons, which are the most common accelerators used in these applications. At the Accelerator Laboratory of the University of Jyväskylä (JYFL), radiation effects testing is currently performed using a K130 cyclotron and a 14 GHz ECRIS at a beam energy of 9.3 MeV/u. A new 18 GHz ECRIS, pushing the limits of the normal conducting ECR technology is under development at JYFL. The performances of existing 18 GHz ion sources have been compared, and based on this analysis, a 16.2 MeV/u beam cocktail with 1999 MeV 126Xe44+ being the most challenging component to has been chosen for development at JYFL. The properties of the suggested beam cocktail are introduced and discussed.

  13. LIGHT SOURCE: Physical design of a 10 MeV LINAC for polymer radiation processing

    Science.gov (United States)

    Feng, Guang-Yao; Pei, Yuan-Ji; Wang, Lin; Zhang, Shan-Cai; Wu, Cong-Feng; Jin, Kai; Li, Wei-Min

    2009-06-01

    In China, polymer radiation processing has become one of the most important processing industries. The radiation processing source may be an electron beam accelerator or a radioactive source. Physical design of an electron beam facility applied for radiation crosslinking is introduced in this paper because of it's much higher dose rate and efficiency. Main part of this facility is a 10 MeV travelling wave electron linac with constant impedance accelerating structure. A start to end simulation concerning the linac is reported in this paper. The codes Opera-3d, Poisson-superfish and Parmela are used to describe electromagnetic elements of the accelerator and track particle distribution from the cathode to the end of the linac. After beam dynamic optimization, wave phase velocities in the structure have been chosen to be 0.56, 0.9 and 0.999 respectively. Physical parameters about the main elements such as DC electron gun, iris-loaded periodic structure, solenoids, etc, are presented. Simulation results proves that it can satisfy the industrial requirement. The linac is under construction. Some components have been finished. Measurements proved that they are in a good agreement with the design values.

  14. A high-brightness repetitively pulsed UV radiation source using a linearly stabilized surface discharge

    Science.gov (United States)

    Bugrimov, S. N.; Kamrukov, A. S.; Kashnikov, G. N.; Kozlov, N. P.; Ovchinnikov, P. A.

    1986-01-01

    A method is proposed for initiating spark plasma discharges on a dielectric surface in the form of strictly rectilinear plasma channels. The method can be implemented using relatively modest (less than 25 kV) working and ignition voltages and does not require any 'hard' electrotechnical loops. Experiments were carried out in order to study the formation dynamics, energy, and spectral brightness characteristics of linearly stabilized surface discharges having linearly stabilized spark channel and the results are discussed. High-speed photographs of the discharges are presented and the spectrum of radiation from the discharges is illustrated in graphic form. It is shown that linearly stabilized discharges can be used to obtain high-power repetitively pulsed sources of CW ultraviolet radiation in the UV region having a brightness temperature of at least 40 K.

  15. Inflatable traversing probe seal

    Science.gov (United States)

    Trimarchi, Paul A.

    1991-01-01

    An inflatable seal acts as a pressure-tight zipper to provide traversing capability for instrumentation rakes and probes. A specially designed probe segment with a teardrop cross-section in the vicinity of the inflatable seal minimizes leakage at the interface. The probe is able to travel through a lengthwise slot in a pressure vessel or wind tunnel section, while still maintaining pressure integrity. The design uses two commercially available inflatable seals, opposing each other, to cover the probe slot in a wind tunnel wall. Proof-of-concept tests were conducted at vessel pressures up to 30 psig, with seals inflated to 50 psig, showing no measurable leakage along the seal's length or around the probe teardrop cross-section. This seal concept can replace the existing technology of sliding face plate/O-ring systems in applications where lengthwise space is limited.

  16. Sodium sulfur battery seal

    Science.gov (United States)

    Mikkor, Mati

    1981-01-01

    This disclosure is directed to an improvement in a sodium sulfur battery construction in which a seal between various battery compartments is made by a structure in which a soft metal seal member is held in a sealing position by holding structure. A pressure applying structure is used to apply pressure on the soft metal seal member when it is being held in sealing relationship to a surface of a container member of the sodium sulfur battery by the holding structure. The improvement comprises including a thin, well-adhered, soft metal layer on the surface of the container member of the sodium sulfur battery to which the soft metal seal member is to be bonded.

  17. Experimental Verification of Isotropic Radiation from a Coherent Dipole Source via Electric-Field-Driven LC Resonator Metamaterials

    Science.gov (United States)

    Tichit, Paul-Henri; Burokur, Shah Nawaz; Qiu, Cheng-Wei; de Lustrac, André

    2013-09-01

    It has long been conjectured that isotropic radiation by a simple coherent source is impossible due to changes in polarization. Though hypothetical, the isotropic source is usually taken as the reference for determining a radiator’s gain and directivity. Here, we demonstrate both theoretically and experimentally that an isotropic radiator can be made of a simple and finite source surrounded by electric-field-driven LC resonator metamaterials designed by space manipulation. As a proof-of-concept demonstration, we show the first isotropic source with omnidirectional radiation from a dipole source (applicable to all distributed sources), which can open up several possibilities in axion electrodynamics, optical illusion, novel transformation-optic devices, wireless communication, and antenna engineering. Owing to the electric- field-driven LC resonator realization scheme, this principle can be readily applied to higher frequency regimes where magnetism is usually not present.

  18. Application of an additive-type mixed probability distribution to the analysis of radiation from a mixture of radioactive sources

    Directory of Open Access Journals (Sweden)

    Dolićanin-Đekić Diana

    2013-01-01

    Full Text Available This paper investigates the possibility of distinguishing between the effects of radiation coming from two or more radioactive isotopes, by using methods of statistical mathematics. The procedure uses a mixed distribution of an additive type. Mathematical treatment is demonstrated herein on an example of analysis of composite radiation from two radioactive sources.

  19. Modelling single shot damage thresholds of multilayer optics for high-intensity short-wavelength radiation sources

    NARCIS (Netherlands)

    Loch, R.A.; Sobierajski, R.; Louis, Eric; Bosgra, J.; Bosgra, J.; Bijkerk, Frederik

    2012-01-01

    The single shot damage thresholds of multilayer optics for highintensity short-wavelength radiation sources are theoretically investigated, using a model developed on the basis of experimental data obtained at the FLASH and LCLS free electron lasers. We compare the radiation hardness of commonly

  20. RZLINE code modelling of distributed tin targets for laser-produced plasma sources of extreme ultraviolet radiation

    NARCIS (Netherlands)

    Koshelev, K.; Noivkov, V.G.; Medvedev, Viacheslav; Grushin, A.S.; Krivtsun, V.M.

    2012-01-01

    Abstract. An integrated model is developed to describe the hydrodynamics, atomic, and radiation processes that take place in extreme ultraviolet (EUV) radiation sources based on a laser-produced plasma with a distributed tin target. The modeling was performed using the RZLINE code—a numerical code

  1. Analysis of the contribution of natural sources of radiation to the total dose received by workers

    Science.gov (United States)

    Sainz, Carlos; Fuente, Ismael; Quindós, Luis; Gutierrez, Jose; Arteche, Jose; Quindós, Luis

    2010-10-01

    People working with ionising radiation are receiving radiation coming from artificial and natural sources. In Spain, as in many other countries, there is a serious control by the national authorities, Spanish Nuclear Safety Council, of the dose the workers receive from artificial sources. However, until the publication of the European Basic Safety Standards Directive, 96/29/EURATOM, the old criteria referring to the "above natural background" were widely used. This directive was incorporated to the Spanish legislation in July 2001 (BOE 178); in its Title VII it recommends to evaluate the dose coming from natural sources and take it into account for establishing the safety criteria. It is noteworthy to assess the natural doses received at homes and the dose received by workers of radioactive installations subject to regulations, and to compare the two results. The social and economical implications of the results derived can be important in the practical application of the recommendations included in the above-mentioned BOE 178 Directive.

  2. Legislating for occupational exposure to sources of natural radiation- the UK approach

    Energy Technology Data Exchange (ETDEWEB)

    Higham, N.; Walker, S.; Thomas, G.

    2004-07-01

    Title VII of EC Directive 96/29/Euratom (the 1996 BSS Directive) for the first time requires Member States to take action in relation to work activities within which the presence of natural radiation sources leads to a significant increase in the exposure of workers or members of the public which cannot be disregarded from the radiation protection point of view. The UK in fact has had legal requirements relating to occupational exposure to natural radiation sources since 1985, in the Ionising Radiations Regulations 1985, made to implement the bulk of the provisions of the previous BSS Directive (80/836/Euratom, as amended by 84/467/Euratom). The Ionising Radiations Regulations 1999, that implement the worker protection requirements of the 1996 Euratom BSS Directive, include similar provisions. The definition of radioactive substance includes any substance which contains one or more radionuclides whose activity cannot be disregarded for the purposes of radiation protection. This means that some low specific activity ores and sands fall within this definition and are therefore subject to relevant requirements of the Regulations. Further advice is given on circumstances in which this may apply. Radon is covered more explicitly by applying the regulations to any work carried out in an atmosphere containing radon 222 gas at a concentration in air, averaged over any 24 hour period, exceeding 400 Bq m-3 except where the concentration of the short-lived daughters of radon 222 in air averaged over any 8 hour working period does not exceed 6.24 x 10-7Jm-3. The Health and Safety Executive pursues a policy of raising awareness of the potential for exposure to radon in the workplace and targeting those employers likely to have a radon problem (based on the use of existing information on homes). The regulatory approach has been to seek remedial building measures so that the workplace is removed from control. HSE is able to offer advice about getting their workplace tested and

  3. Foil Face Seal Testing

    Science.gov (United States)

    Munson, John

    2009-01-01

    In the seal literature you can find many attempts by various researchers to adapt film riding seals to the gas turbine engine. None have been successful, potential distortion of the sealing faces is the primary reason. There is a film riding device that does accommodate distortion and is in service in aircraft applications, namely the foil bearing. More specifically a foil thrust bearing. These are not intended to be seals, and they do not accommodate large axial movement between shaft & static structure. By combining the 2 a unique type of face seal has been created. It functions like a normal face seal. The foil thrust bearing replaces the normal primary sealing surface. The compliance of the foil bearing allows the foils to track distortion of the mating seal ring. The foil seal has several perceived advantages over existing hydrodynamic designs, enumerated in the chart. Materials and design methodology needed for this application already exist. Also the load capacity requirements for the foil bearing are low since it only needs to support itself and overcome friction forces at the antirotation keys.

  4. Novel radiation sources using relativistic electrons from infrared to x-rays

    CERN Document Server

    Rullhusen, P; Dhez, P

    1998-01-01

    The purpose of this book is to give a description of the state of the art in theoretical and experimental work achieved in radiation source development. It summarizes clearly and comprehensibly, the basic physical aspects needed to understand the phenomena, and also provides the interested reader with sufficient literature to be able to follow the development in more detail. In addition, it contains a unified view of most theoretical effects and their common properties. The most recent developments as well as references to further work can be found in this volume. In many cases, review article

  5. High Test Peroxide High Sealing Conical Seal Project

    Data.gov (United States)

    National Aeronautics and Space Administration — High Test Peroxide (HTP) Highly Compatible High Sealing Conical Seals are necessary for ground test operations and space based applications. Current conical seals...

  6. Physiologically gated microbeam radiation using a field emission x-ray source array

    Energy Technology Data Exchange (ETDEWEB)

    Chtcheprov, Pavel, E-mail: PavelC@unc.edu, E-mail: zhou@email.unc.edu [Department of Biomedical Engineering, University of North Carolina, 152 MacNider Hall, Campus Box 7575, Chapel Hill, North Carolina 27599 (United States); Burk, Laurel; Inscoe, Christina; Ger, Rachel; Hadsell, Michael; Lu, Jianping [Department of Physics and Astronomy, University of North Carolina, Phillips Hall, CB #3255, 120 East Cameron Avenue, Chapel Hill, North Carolina 27599 (United States); Yuan, Hong [Department of Radiology, University of North Carolina, 2006 Old Clinic, CB #7510, Chapel Hill, North Carolina 27599 (United States); Zhang, Lei [Department of Applied Physical Sciences, University of North Carolina, Chapman Hall, CB#3216, Chapel Hill, North Carolina 27599 (United States); Chang, Sha [Department of Radiation Oncology, University of North Carolina, 101 Manning Drive, Chapel Hill, North Carolina 27514 and UNC Lineberger Comprehensive Cancer Center, University of North Carolina, 101 Manning Drive, Chapel Hill, North Carolina 27514 (United States); Zhou, Otto, E-mail: PavelC@unc.edu, E-mail: zhou@email.unc.edu [Department of Physics and Astronomy, University of North Carolina, Phillips Hall, CB #3255, 120 East Cameron Avenue, Chapel Hill, North Carolina 27599 and UNC Lineberger Comprehensive Cancer Center, University of North Carolina, 101 Manning Drive, Chapel Hill, North Carolina 27514 (United States)

    2014-08-15

    Purpose: Microbeam radiation therapy (MRT) uses narrow planes of high dose radiation beams to treat cancerous tumors. This experimental therapy method based on synchrotron radiation has been shown to spare normal tissue at up to 1000 Gy of peak entrance dose while still being effective in tumor eradication and extending the lifetime of tumor-bearing small animal models. Motion during treatment can lead to significant movement of microbeam positions resulting in broader beam width and lower peak to valley dose ratio (PVDR), which reduces the effectiveness of MRT. Recently, the authors have demonstrated the feasibility of generating microbeam radiation for small animal treatment using a carbon nanotube (CNT) x-ray source array. The purpose of this study is to incorporate physiological gating to the CNT microbeam irradiator to minimize motion-induced microbeam blurring. Methods: The CNT field emission x-ray source array with a narrow line focal track was operated at 160 kVp. The x-ray radiation was collimated to a single 280 μm wide microbeam at entrance. The microbeam beam pattern was recorded using EBT2 Gafchromic{sup ©} films. For the feasibility study, a strip of EBT2 film was attached to an oscillating mechanical phantom mimicking mouse chest respiratory motion. The servo arm was put against a pressure sensor to monitor the motion. The film was irradiated with three microbeams under gated and nongated conditions and the full width at half maximums and PVDRs were compared. An in vivo study was also performed with adult male athymic mice. The liver was chosen as the target organ for proof of concept due to its large motion during respiration compared to other organs. The mouse was immobilized in a specialized mouse bed and anesthetized using isoflurane. A pressure sensor was attached to a mouse's chest to monitor its respiration. The output signal triggered the electron extraction voltage of the field emission source such that x-ray was generated only

  7. Remote sensing constraints on aerosol sources, physical properties and direct radiative forcing

    Science.gov (United States)

    Henze, D. K.; Meland, B. S.; Xu, X.; Wang, J.; Akhtar, F.; Hemming, B.; Pinder, R. W.; Loughlin, D.

    2012-12-01

    Aerosols contribute to air pollution and climate change, yet their origins, physical properties and fates in the atmosphere are often uncertain. Here we present constraints on aerosol sources and their physical properties that may be obtained from remote sensing observations through application of an adjoint chemical transport model (GEOS-Chem) for sensitivity and data assimilation applications. We first consider the information content of remote sensing of light scattering intensity, such as from MODIS, and compare this to the value of hypothetical polarimetric measurements from an instrument such as APS. The degree to which these types of observations are capable of constraining sources, or sources versus microphysical properties such as aerosol size and refractive index, are considered. Model-derived source attributions of aerosol direct radiative forcing from individual aerosol and aerosol precursor emissions are presented next. These are combined with metrics of absolute regional temperature potentials to map the relationship between aerosol sources and global surface temperature. This mapping quantifies the potential of future assimilation and measurement studies to reduce uncertainty in understanding aerosol impacts on climate.

  8. Pillow seal system at the BigRIPS separator

    Energy Technology Data Exchange (ETDEWEB)

    Tanaka, K., E-mail: ktanaka@riken.jp; Inabe, N.; Yoshida, K.; Kusaka, K.; Kubo, T.

    2013-12-15

    Highlights: • Pillow seal system has been installed for a high-intensity RI-beam facility at RIKEN. • It is aimed at facilitating remote maintenance under high residual radiation. • Local radiation shields are integrated with one of the pillow seals. • Pillow seals have been aligned to the beam axis within 1mm accuracy. • A leakage rate of 10{sup –9} Pa m{sup 3}/s has been achieved with our pillow seal system. -- Abstract: We have designed and installed a pillow seal system for the BigRIPS fragment separator at the RIKEN Radioactive Isotope Beam Factory (RIBF) to facilitate remote maintenance in a radioactive environment. The pillow seal system is a device to connect a vacuum chamber and a beam tube. It allows quick attachment and detachment of vacuum connections in the BigRIPS separator and consists of a double diaphragm with a differential pumping system. The leakage rate achieved with this system is as low as 10{sup –9} Pa m{sup 3}/s. We have also designed and installed a local radiation-shielding system, integrated with the pillow seal system, to protect the superconducting magnets and to reduce the heat load on the cryogenic system. We present an overview of the pillow seal and the local shielding systems.

  9. Structural Design and Sealing Performance Analysis of Biomimetic Sealing Ring

    OpenAIRE

    Chuanjun Han; Han Zhang; Jie Zhang

    2015-01-01

    In order to reduce the failure probability of rubber sealing rings in reciprocating dynamic seal, a new structure of sealing ring based on bionics was designed. The biomimetic ring has three concave ridges and convex bulges on each side which are very similar to earthworms. Bulges were circularly designed and sealing performances of the biomimetic ring in both static seal and dynamic seal were simulated by FEM. In addition, effects of precompression, medium pressure, speed, friction coefficie...

  10. Orbit correction using an eigenvector method with constraints for synchrotron radiation sources

    Science.gov (United States)

    Harada, Kentaro; Obina, Takashi; Kobayashi, Yukinori; Nakamura, Norio; Takaki, Hiroyuki; Sakai, Hiroshi

    2009-06-01

    An eigenvector method with constraints (EVC) is proposed as a new orbit correction scheme for synchrotron light sources. EVC efficiently corrects the global orbit in a storage ring, and can simultaneously perform exact correction of local orbits without deterioration of the global orbit. To demonstrate the advantages of EVC over the ordinary eigenvector method (EV), we carried out experimental studies at the Photon Factory storage ring (PF-ring) and the Photon Factory Advanced Ring (PF-AR) at the High Energy Accelerator Research Organization (KEK). The performance of EVC was systematically examined at PF-ring and PF-AR. The experimental results agreed well with the simulated ones. Consequently, we confirmed that EVC easily realized orbit correction for both global and local orbits, and that it was very effective for the beam stabilization of synchrotron radiation (SR) sources.

  11. Orbit correction using an eigenvector method with constraints for synchrotron radiation sources

    Energy Technology Data Exchange (ETDEWEB)

    Harada, Kentaro [Photon Factory, High Energy Accelerator Research Organization, 1-1, Oho, Tsukuba, Ibaraki 305-0801 (Japan)], E-mail: kentaro.harada@kek.jp; Obina, Takashi; Kobayashi, Yukinori [Photon Factory, High Energy Accelerator Research Organization, 1-1, Oho, Tsukuba, Ibaraki 305-0801 (Japan); Nakamura, Norio; Takaki, Hiroyuki; Sakai, Hiroshi [Institute for Solid State Physics, University of Tokyo, 5-1-5, Kashiwanoha, Kashiwa, Chiba 277-8581 (Japan)

    2009-06-11

    An eigenvector method with constraints (EVC) is proposed as a new orbit correction scheme for synchrotron light sources. EVC efficiently corrects the global orbit in a storage ring, and can simultaneously perform exact correction of local orbits without deterioration of the global orbit. To demonstrate the advantages of EVC over the ordinary eigenvector method (EV), we carried out experimental studies at the Photon Factory storage ring (PF-ring) and the Photon Factory Advanced Ring (PF-AR) at the High Energy Accelerator Research Organization (KEK). The performance of EVC was systematically examined at PF-ring and PF-AR. The experimental results agreed well with the simulated ones. Consequently, we confirmed that EVC easily realized orbit correction for both global and local orbits, and that it was very effective for the beam stabilization of synchrotron radiation (SR) sources.

  12. Report of the second workshop on synchrotron radiation sources for x-ray lithography

    Energy Technology Data Exchange (ETDEWEB)

    Barton, M.Q.; Craft, B.; Williams, G.P. (eds.)

    1986-01-01

    The reported workshop is part of an effort to implement a US-based x-ray lithography program. Presentations include designs for three storage rings (one superconducting and two conventional) and an overview of a complete lithography program. The background of the effort described, the need for synchrotron radiation, and the international competition in the area are discussed briefly. The technical feasibility of x-ray lithography is discussed, and synchrotron performance specifications and construction options are given, as well as a near-term plan. It is recommended that a prototype synchrotron source be built as soon as possible, and that a research and development plan on critical technologies which could improve cost effectiveness of the synchrotron source be established. It is further recommended that a small number of second generation prototype synchrotrons be distributed to IC manufacturing centers to expedite commercialization. (LEW)

  13. Safety Analysis Report for Primary Capsule of Ir-192 Radiation Source

    Energy Technology Data Exchange (ETDEWEB)

    Lee, J. C.; Bang, K. S.; Choi, W. S.; Seo, K. S.; Son, K. J.; Park, W. J

    2008-12-15

    All of the source capsules to transport a special form radioactive material should be designed and fabricated in accordance with the design criteria prescribed in IAEA standards and domestic regulations. The objective of this project is to prove the safety of a primary capsule for Ir-192 radiation source which produced in the HANARO. The safety tests of primary capsules were carried out for the impact, percussion and heat conditions. And leakage tests were carried out before and after the each tests. The capsule showed slight scratches and their deformations were not found after each tests. It also met the allowable limits of leakage rate after each test. Therefore, it has been verified that the capsule was designed and fabricated to meet all requirements for the special form radioactive materials.

  14. Measurement of the energy and power radiated by a pulsed blackbody x-ray source.

    Energy Technology Data Exchange (ETDEWEB)

    Chandler, Gordon Andrew; McDaniel, Dillon Heirman; Jorgenson, Roy E.; Warne, Larry Kevin; Dropinski, Steven Clark; Hanson, Donald L.; Johnson, William Arthur; York, Mathew William; Lewis, D.F. (International Specialty Products, Wayne , NJ); Korde, R. (International Radiation Detectors, Torrance, CA); Haslett, C.L. (Ktech Corporation, Albuquerque, NM); Wall, D.L. (Resonetics, Nashua, New hampshire); Ruggles, Laurence E.; Ramirez, L.E. (ATK Mission Research Corporation, Albuquerque, NM); Stygar, William A.; Porter, John Larry, Jr.; McKenney, John Lee; Bryce, Edwin Anthony; Cuneo, Michael Edward; Torres, Jose A.; Mills, Jerry Alan; Leeper, Ramon Joe; McGurn, John Stephen; Fehl, David Lee; Spielman, R. B. (International Specialty Products, Wayne , NJ); Pyle, John H. (Ktech Corporation, Albuquerque, NM); Mazarakis, Michael Gerrassimos; Ives, Harry Crockett, III (EG& G, Albuquerque, NM); Seamen, Johann F.; Simpson, Walter W.

    2006-02-01

    We have developed a diagnostic system that measures the spectrally integrated (i.e. the total) energy and power radiated by a pulsed blackbody x-ray source. The total-energy-and-power (TEP) diagnostic system is optimized for blackbody temperatures between 50 and 350 eV. The system can view apertured sources that radiate energies and powers as high as 2 MJ and 200 TW, respectively, and has been successfully tested at 0.84 MJ and 73 TW on the Z pulsed-power accelerator. The TEP system consists of two pinhole arrays, two silicon-diode detectors, and two thin-film nickel bolometers. Each of the two pinhole arrays is paired with a single silicon diode. Each array consists of a 38 x 38 square array of 10-{micro}m-diameter pinholes in a 50-{micro}m-thick tantalum plate. The arrays achromatically attenuate the x-ray flux by a factor of {approx}1800. The use of such arrays for the attenuation of soft x rays was first proposed by Turner and co-workers [Rev. Sci. Instrum. 70, 656 (1999)RSINAK0034-674810.1063/1.1149385]. The attenuated flux from each array illuminates its associated diode; the diode's output current is recorded by a data-acquisition system with 0.6-ns time resolution. The arrays and diodes are located 19 and 24 m from the source, respectively. Because the diodes are designed to have an approximately flat spectral sensitivity, the output current from each diode is proportional to the x-ray power. The nickel bolometers are fielded at a slightly different angle from the array-diode combinations, and view (without pinhole attenuation) the same x-ray source. The bolometers measure the total x-ray energy radiated by the source and--on every shot--provide an in situ calibration of the array-diode combinations. Two array-diode pairs and two bolometers are fielded to reduce random uncertainties. An analytic model (which accounts for pinhole-diffraction effects) of the sensitivity of an array-diode combination is presented.

  15. Measurement of the energy and power radiated by a pulsed blackbody x-ray source

    Directory of Open Access Journals (Sweden)

    H. C. Ives

    2006-11-01

    Full Text Available We have developed a diagnostic system that measures the spectrally integrated (i.e. the total energy and power radiated by a pulsed blackbody x-ray source. The total-energy-and-power (TEP diagnostic system is optimized for blackbody temperatures between 50 and 350 eV. The system can view apertured sources that radiate energies and powers as high as 2 MJ and 200 TW, respectively, and has been successfully tested at 0.84 MJ and 73 TW on the Z pulsed-power accelerator. The TEP system consists of two pinhole arrays, two silicon-diode detectors, and two thin-film nickel bolometers. Each of the two pinhole arrays is paired with a single silicon diode. Each array consists of a 38×38 square array of 10-μm-diameter pinholes in a 50-μm-thick tantalum plate. The arrays achromatically attenuate the x-ray flux by a factor of ∼1800. The use of such arrays for the attenuation of soft x rays was first proposed by Turner and co-workers [Rev. Sci. Instrum. 70, 656 (1999RSINAK0034-674810.1063/1.1149385]. The attenuated flux from each array illuminates its associated diode; the diode’s output current is recorded by a data-acquisition system with 0.6-ns time resolution. The arrays and diodes are located 19 and 24 m from the source, respectively. Because the diodes are designed to have an approximately flat spectral sensitivity, the output current from each diode is proportional to the x-ray power. The nickel bolometers are fielded at a slightly different angle from the array-diode combinations, and view (without pinhole attenuation the same x-ray source. The bolometers measure the total x-ray energy radiated by the source and—on every shot—provide an in situ calibration of the array-diode combinations. Two array-diode pairs and two bolometers are fielded to reduce random uncertainties. An analytic model (which accounts for pinhole-diffraction effects of the sensitivity of an array-diode combination is presented.

  16. Response of a hybrid pixel detector (MEDIPIX3) to different radiation sources for medical applications

    Energy Technology Data Exchange (ETDEWEB)

    Chumacero, E. Miguel; De Celis Alonso, B.; Martínez Hernández, M. I.; Vargas, G.; Moreno Barbosa, E., E-mail: emoreno.emb@gmail.com [Facultad de Ciencias Físico Matemáticas, Benemérita Universidad Autónoma de Puebla, Av. San Claudio y Rio Verde, Puebla (Mexico); Moreno Barbosa, F. [Hospital General del Sur Hospital de la Mujer, Puebla (Mexico)

    2014-11-07

    The development in semiconductor CMOS technology has enabled the creation of sensitive detectors for a wide range of ionizing radiation. These devices are suitable for photon counting and can be used in imaging and tomography X-ray diagnostics. The Medipix[1] radiation detection system is a hybrid silicon pixel chip developed for particle tracking applications in High Energy Physics. Its exceptional features (high spatial and energy resolution, embedded ultra fast readout, different operation modes, etc.) make the Medipix an attractive device for applications in medical imaging. In this work the energy characterization of a third-generation Medipix chip (Medipix3) coupled to a silicon sensor is presented. We used different radiation sources (strontium 90, iron 55 and americium 241) to obtain the response curve of the hybrid detector as a function of energy. We also studied the contrast of the Medipix as a measure of pixel noise. Finally we studied the response to fluorescence X rays from different target materials (In, Pd and Cd) for the two data acquisition modes of the chip; single pixel mode and charge summing mode.

  17. Coupling of MASH-MORSE Adjoint Leakages with Space- and Time-Dependent Plume Radiation Sources

    Energy Technology Data Exchange (ETDEWEB)

    Slater, C.O.

    2001-04-20

    In the past, forward-adjoint coupling procedures in air-over-ground geometry have typically involved forward fluences arising from a point source a great distance from a target or vehicle system. Various processing codes were used to create localized forward fluence files that could be used to couple with the MASH-MORSE adjoint leakages. In recent years, radiation plumes that result from reactor accidents or similar incidents have been modeled by others, and the source space and energy distributions as a function of time have been calculated. Additionally, with the point kernel method, they were able to calculate in relatively quick fashion free-field radiation doses for targets moving within the fluence field or for stationary targets within the field, the time dependence for the latter case coming from the changes in position, shape, source strength, and spectra of the plume with time. The work described herein applies the plume source to the MASH-MORSE coupling procedure. The plume source replaces the point source for generating the forward fluences that are folded with MASH-MORSE adjoint leakages. Two types of source calculations are described. The first is a ''rigorous'' calculation using the TORT code and a spatially large air-over-ground geometry. For each time step desired, directional fluences are calculated and are saved over a predetermined region that encompasses a structure within which it is desired to calculate dose rates. Processing codes then create the surface fluences (which may include contributions from radiation sources that deposit on the roof or plateout) that will be coupled with the MASH-MORSE adjoint leakages. Unlike the point kernel calculations of the free-field dose rates, the TORT calculations in practice include the effects of ground scatter on dose rates and directional fluences, although the effects may be underestimated or overestimated because of the use of necessarily coarse mesh and quadrature in order to

  18. Ultraviolet out-of-band radiation studies in laser tin plasma sources

    Science.gov (United States)

    Parchamy, Homaira; Szilagyi, John; Masnavi, Majid; Richardson, Martin

    2017-11-01

    Out-of-band long wavelength emission measurements from high power, high-repetition-rate extreme-ultra-violet lithography (EUVL) laser plasma sources are imperative to estimating heat deposition in EUV mirrors, and the impact of short wavelength light transported through the imaging system to the wafer surface. This paper reports a series of experiments conducted to measure the absolute spectral irradiances of laser-plasmas produced from planar tin targets over the wavelength region of 124 to 164 nm by 1.06 μm wavelength, 10 ns full-width-at-half-maximum Gaussian laser pulses. The use of spherical targets is relevant to the EUVL source scenario. Although plasmas produced from planar surfaces evolve differently, there is a close similarity to the evolution of current from 10.6 μm CO2 laser EUVL sources, which use a pre-pulse from a lower energy solid-state laser to melt and reform an initial spherical droplet into a thin planar disc target. The maximum of radiation conversion efficiency in the 124-164 nm wavelength band (1%/2πsr) occurs at the laser intensity of 1010 W cm-2. A developed collisional-radiative model reveals the strong experimental spectra that originate mainly from the 4d105p2-4d105s5p, 4d105p-4d105s resonance lines, and 4d95p-4d95s unresolved transition arrays from Sn III, Sn IV, and Sn V ions, respectively. The calculated conversion efficiencies using a 2D radiation-hydrodynamics model are in agreement with the measurements. The model predicts the out-of-band (100-400 nm) radiation conversion efficiencies generated by both 1.06 and 10.6 μm pulses. The 10.6 μm laser pulse produces a higher conversion efficiency (12%/2πsr) at the lower laser intensity of 109 W cm-2.

  19. THz and Sub-THz Capabilities of a Table-Top Radiation Source Driven by an RF Thermionic Electron Gun

    Energy Technology Data Exchange (ETDEWEB)

    Smirnov, Alexei V.; Agustsson, R.; Boucher, S.; Campese, Tara; Chen, Y.C.; Hartzell, Josiah J.; Jocobson, B.T.; Murokh, A.; O' Shea, F.H.; Spranza, E.; Berg, W.; Borland, M.; Dooling, J. C.; Erwin, L.; Lindberg, R. R.; Pasky, S.J.; Sereno, N.; Sun, Y.; Zholents, A.

    2017-06-01

    Design features and experimental results are presented for a sub-mm wave source [1] based on APS RF thermionic electron gun. The setup includes compact alpha-magnet, quadrupoles, sub-mm-wave radiators, and THz optics. The sub-THz radiator is a planar, oversized structure with gratings. Source upgrade for generation frequencies above 1 THz is discussed. The THz radiator will use a short-period undulator having 1 T field amplitude, ~20 cm length, and integrated with a low-loss oversized waveguide. Both radiators are integrated with a miniature horn antenna and a small ~90°-degree in-vacuum bending magnet. The electron beamline is designed to operate different modes including conversion to a flat beam interacting efficiently with the radiator. The source can be used for cancer diagnostics, surface defectoscopy, and non-destructive testing. Sub-THz experiment demonstrated a good potential of a robust, table-top system for generation of a narrow bandwidth THz radiation. This setup can be considered as a prototype of a compact, laser-free, flexible source capable of generation of long trains of Sub-THz and THz pulses with repetition rates not available with laser-driven sources.

  20. Rotary shaft seal

    Science.gov (United States)

    Langebrake, C.O.

    1984-01-01

    The invention is a novel rotary shaft seal assembly which provides positive-contact sealing when the shaft is not rotated and which operates with its sealing surfaces separated by a film of compressed ambient gas whose width is independent of the speed of shaft rotation. In a preferred embodiment, the assembly includes a disc affixed to the shaft for rotation therewith. Axially movable, non-rotatable plates respectively supported by sealing bellows are positioned on either side of the disc to be in sealing engagement therewith. Each plate carries piezoelectric transucer elements which are electrically energized at startup to produce films of compressed ambient gas between the confronting surfaces of the plates and the disc. Following shutdown of the shaft, the transducer elements are de-energized. A control circuit responds to incipient rubbing between the plate and either disc by altering the electrical input to the transducer elements to eliminate rubbing.

  1. Design of an Yb-169 source optimized for gold nanoparticle-aided radiation therapy

    Energy Technology Data Exchange (ETDEWEB)

    Reynoso, Francisco J.; Manohar, Nivedh [Nuclear/Radiological Engineering and Medical Physics Programs, Woodruff School of Mechanical Engineering, Georgia Institute of Technology, Atlanta, Georgia 30332-0405 (United States); Krishnan, Sunil [Department of Radiation Oncology, The University of Texas MD Anderson Cancer Center, Houston, Texas 77030 (United States); Cho, Sang Hyun, E-mail: scho@mdanderson.org [Department of Radiation Physics and Department of Imaging Physics, The University of Texas MD Anderson Cancer Center, Houston, Texas 77030 (United States)

    2014-10-15

    Purpose: To find an optimum design of a new high-dose rate ytterbium (Yb)-169 brachytherapy source that would maximize the dose enhancement during gold nanoparticle-aided radiation therapy (GNRT), while meeting practical constraints for manufacturing a clinically relevant brachytherapy source. Methods: Four different Yb-169 source designs were considered in this investigation. The first three source models had a single encapsulation made of one of the following materials: aluminum, titanium, and stainless steel. The last source model adopted a dual encapsulation design with an inner aluminum capsule surrounding the Yb-core and an outer titanium capsule. Monte Carlo (MC) simulations using the Monte Carlo N-Particle code version 5 (MCNP5) were conducted initially to investigate the spectral changes caused by these four source designs and the associated variations in macroscopic dose enhancement across the tumor loaded with gold nanoparticles (GNPs) at 0.7% by weight. Subsequent MC simulations were performed using the EGSnrc and NOREC codes to determine the secondary electron spectra and microscopic dose enhancement as a result of irradiating the GNP-loaded tumor with the MCNP-calculated source spectra. Results: Effects of the source filter design were apparent in the current MC results. The intensity-weighted average energy of the Yb-169 source varied from 108.9 to 122.9 keV, as the source encapsulation material changed from aluminum to stainless steel. Accordingly, the macroscopic dose enhancement calculated at 1 cm away from the source changed from 51.0% to 45.3%. The sources encapsulated by titanium and aluminum/titanium combination showed similar levels of dose enhancement, 49.3% at 1 cm, and average energies of 113.0 and 112.3 keV, respectively. While the secondary electron spectra due to the investigated source designs appeared to look similar in general, some differences were noted especially in the low energy region (<50 keV) of the spectra suggesting the

  2. Bipolar ionization source for ion mobility spectrometry based on vacuum ultraviolet radiation induced photoemission and photoionization.

    Science.gov (United States)

    Chen, Chuang; Dong, Can; Du, Yongzhai; Cheng, Shasha; Han, Fenglei; Li, Lin; Wang, Weiguo; Hou, Keyong; Li, Haiyang

    2010-05-15

    A novel bipolar ionization source based on a commercial vacuum-UV Kr lamp has been developed for ion mobility spectrometry (IMS), which can work in both negative and positive ion mode. Its reactant ions formed in negative ion mode were predominantly assigned to be O(3)(-)(H(2)O)(n), which is different from that of the (63)Ni source with purified air as carrier and drift gases. The formation of O(3)(-)(H(2)O)(n) was due to the production of ozone caused by ultraviolet radiation, and the ozone concentration was measured to be about 1700 ppmv by iodometric titration method. Inorganic molecules such as SO(2), CO(2), and H(2)S can be easily detected in negative ion mode, and a linear dynamic range of 3 orders of magnitude and a limit of detection (S/N = 3) of 150 pptv were obtained for SO(2). Its performance as a negative ion source was investigated by the detection of ammonium nitrate fuel oil explosive, N-nitrobis(2-hydroxyethyl)amine dinitrate, cyclo-1,3,5-trimethylene-2,4,6-trinitramine, and pentaerythritol tetranitrate (PETN) at 150 degrees C. The limit of detection was reached at 45 pg for PETN, which was much lower than the 190 pg using (63)Ni ion mobility spectrometry under the same experimental condition. Also, its performance as an ordinary photoionization source was investigated in detecting benzene, toluene, and m-xylene.

  3. Performance evaluation of fog seals on chip seals and verification of fog seal field tests

    National Research Council Canada - National Science Library

    Kim, Y. Richard; Im, Jeong Hyuk

    2015-01-01

    .... To mitigate a major problem with chip seals, i.e., the loose aggregate particles, fog seals, which are composed of an emulsified product placed on top of the chip seal, can be used to help control the loose aggregate...

  4. Apartment Compartmentalization With an Aerosol-Based Sealing Process

    Energy Technology Data Exchange (ETDEWEB)

    Maxwell, Sean [Consortium for Advanced Residential Buildings (CARB), Norwalk, CT (United States); Berger, David [Consortium for Advanced Residential Buildings (CARB), Norwalk, CT (United States); Harrington, Curtis [Univ. of California, Davis, CA (United States)

    2015-03-01

    The U.S. Department of Energy Building America Team, Consortium for Advanced Residential Buildings, sought to demonstrate this new technology application in a new construction multifamily building in Queens, New York. The effectiveness of the sealing process was evaluated by three methods: air leakage testing of overall apartment before-and-after sealing, point-source testing of individual leaks, and pressure measurements in the walls of an apartment during sealing.

  5. Separation of radiated sound field components from waves scattered by a source under non-anechoic conditions

    DEFF Research Database (Denmark)

    Fernandez Grande, Efren; Jacobsen, Finn

    2010-01-01

    A method of estimating the sound field radiated by a source under non-anechoic conditions has been examined. The method uses near field acoustic holography based on a combination of pressure and particle velocity measurements in a plane near the source for separating outgoing and ingoing wave...... components. The outgoing part of the sound field is composed of both radiated and scattered waves. The method compensates for the scattered components of the outgoing field on the basis of the boundary condition of the problem, exploiting the fact that the sound field is reconstructed very close...... to the source. Thus the radiated free-field component is estimated simultaneously with solving the inverse problem of reconstructing the sound field near the source. The method is particularly suited to cases in which the overall contribution of reflected sound in the measurement plane is significant....

  6. Leakage test evaluation used for qualification of iodine-125 seeds sealing

    Energy Technology Data Exchange (ETDEWEB)

    Feher, Anselmo; Rostelato, Maria E.C.M.; Zeituni, Carlos A.; Calvo, Wilson A.P.; Somessari, Samir L.; Moura, Joao A.; Moura, Eduardo S.; Souza, Carla D.; Rela, Paulo R. [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), Sao Paulo, SP (Brazil)], e-mail: afeher@ipen.br, e-mail: elisaros@ipen.br, e-mail: czeituni@pobox.com, e-mail: wapcalco@ipen.br, e-mail: somessar@ipen.br, e-mail: jmoura31@yahoo.com.br, e-mail: esmoura@ipen.br, e-mail: cdsouza@ipen.br, e-mail: prela@ipen.br

    2009-07-01

    The prostate cancer is a problem of public health in Brazil, and the second cause of cancer deaths in men, exceeded only by lung cancer. Among the possible treatments available for prostate cancer is brachytherapy, in which small seeds containing Iodine-125 radioisotope are implanted in the prostate. The seed consists of a sealed titanium tube measuring 0.8 mm external diameter and 4.5 mm in length, containing a central silver wire with adsorbed Iodine-125. The tube sealing is made with titanium at the ends, using electric arc welding or laser process. This sealing must be leakage-resistant and free of cracks, therefore avoiding the Iodine-125 to deposit in the silver wire to escape and spread into the human body. To ensure this problem does not occur, rigorous leakage tests, in accordance with the standard Radiation protection - Sealed Radioactive Sources - leakage Test Methods - ISO 9978, should be applied. The aim of this study is to determine, implement and evaluate the leakage test to be used in the Iodine-125 seeds production, in order to qualify the sealing procedure. The standard ISO 9978 presents a list of tests to be carried out according to the type of source. The preferential methods for brachytherapy sources are soaking and helium. To assess the seeds leakage, the method of immersion test at room temperature was applied. The seeds are considered leakage-free if the detected activity does not exceed the 185 Bq (5 nCi). An Iodine standard was prepared and its value determined in a sodium iodide detector. A liquid scintillation counter was calibrated with the standard for seeds leakage tests. Forty-eight seeds were welded for these tests. (author)

  7. Analysis of the spatial dose according to the type of radiation source used in multi-bed hospital room

    Energy Technology Data Exchange (ETDEWEB)

    Jang, Dong Gun [Dept. of Nuclear Medicine, Dongnam Institute of Radiological and Medical Sciences Cancer center, Busan (Korea, Republic of); Kim, Jung Hoon [Dept. of Radiological Science, College of Health Sciences, Catholic University of Pusan, Busan (Korea, Republic of); Park, Eun Tae [Dept. of Radiation Oncology, Busan Paik Hospital, Inje University, Busan (Korea, Republic of)

    2017-09-15

    Medical radiation offers significant benefits in diagnosing and treating patients, but it also generates unnecessary radiation exposure to those nearby. Accordingly, the objective of the present study was to analyze spatial dose rate according to types of radiation source term in multi-bed hospital rooms occupied by patients and general public. MCNPX was used for geometric simulation of multi-bed hospital rooms and radiation source terms, while the radiation source terms were established as whole body bone scan patients and imaging using a portable X-ray generator. The results of simulation on whole body bone scan patients showed 3.46 μSv/hr to another patient position, while experimental results on imaging using a portable X-ray generator showed 1.47 × 10{sup -8} μSv/irradiation to another patient position in chest imaging and 2.97 × 10{sup -8} μSv/irradiation to another patient position in abdomen imaging. Multi-bed hospital room, unnecessary radiation generated in the surrounding patients, while legal regulations and systematic measures are needed for radiation exposure in multi-bed hospital rooms that are currently lacking in Korea.

  8. On the use of HDR 60Co source with the MammoSite radiation therapy system.

    Science.gov (United States)

    Baltas, D; Lymperopoulou, G; Zamboglou, N

    2008-12-01

    This work summarizes Monte Carlo results in order to evaluate the potential of using HDR 60Co sources in accelerated partial breast irradiation (APBI) with the MammoSite applicator. Simulations have been performed using the MCNP5 Monte Carlo Code, in simple geometries comprised of two concentric spheres; the internal consisting of selected concentrations, C, of a radiographic contrast solution in water (Omnipaque 300) to simulate the MammoSite balloon and the external consisting of water to simulate surrounding tissue. The magnitude of the perturbation of delivered dose due to the radiographic contrast medium used in the MammoSite applicator is calculated. At the very close vicinity of the balloon surface, a dose build-up region is observed, which leads to a dose overestimation by the treatment planning system (TPS) which depends on Omnipaque 300 solution concentration (and is in order of 2.3%, 3.0%, and 4.5%, respectively, at 1 mm away from the balloon - water interface, for C=10%, 15%, and 20%). However, dose overestimation by the TPS is minimal for points lying at the prescription distance (d=1 cm) or beyond, for all simulated concentrations and radii of MammoSite balloon. An analytical estimation of the integral dose outside the CTV in the simple geometries simulated shows that dose to the breast for MammoSite applications is expected to be comparable using HDR 60Co and 192Ir sources, and higher than that for 169Yb. The higher enegies of 60Co sources result to approximately twice radiation protection requirements as compared to 169Ir sources. However, they allow for more accurate dosimetry calculation with currently used treatment planning algorithms for 60Co sources, compared to 169Ir.

  9. On application of low doses from beta radiation source in OSL retrospective dosimetry

    Science.gov (United States)

    Przegietka, K.; Chruscinska, A.

    2014-11-01

    The paper reports on three levels of dose rates obtainable from single beta source: (133±3) mGy/s, (17.8±0.3) mGy/s and (1.94±0.04) mGy/s, as calibrated for quartz sand grains. These values were achieved for different attenuation stages of beta radiation emitted by standard 90Sr/90Y source with the nominal activity of 1.48 GBq attached to an automatic luminescence reader. Lower dose rates give opportunity for exact dosing, which is especially required in luminescence dating applied to young samples as well as in environmental dosimetry. Moreover new method for determining time lag in opening the source in the Riso beta irradiator is presented. This allowed to resolve the contradiction appearing in the literature. The time delay was found to be (0.15±0.01) s per single irradiation. For improving accuracy the dose rate correction is suggest to be taken into account for irradiations shorter than 30 s.

  10. Computation of sound radiation by a driver in a cabinet using a substitute source approach.

    Science.gov (United States)

    Lindberg, Anders; Pavić, Goran

    2015-08-01

    Sound radiation by a driver set in a rigid closed cabinet is modeled analytically using the principle of wave superposition. The driver-cabinet assembly is replaced by an array of volumeless substitute sources-monopoles-confined within its surface. The role of substitute sources is to reproduce the sound field exterior to the surface as close to the original field as possible. The frequency dependent positions and strengths of substitute monopoles are optimized by an iterative search procedure aimed at matching the prescribed surface boundary conditions of the original source. The time-consuming optimization of monopole positions is carried out at narrowband center frequencies reducing the computational cost without significant loss of accuracy. The consistency of computed results is verified by checking the power output through the cabinet surface. Modeling is done for anechoic and semi-anechoic conditions. The model has been validated experimentally in a semi-anechoic room with satisfactory results using a mid-range driver set in a closed-box baffle.

  11. Generalized Reference Fields and Source Interpolation for the Difference Formulation of Radiation Transport

    Energy Technology Data Exchange (ETDEWEB)

    Luu, T C; Brooks, E D; Szoke, A

    2009-02-05

    In the difference formulation for the transport of thermally emitted photons, the photon intensity is defined relative to a reference field, the black body at the local material temperature. This choice of reference field combines the separate emission and absorption terms that nearly cancel, removing the dominant cause of noise in the Monte Carlo solution of thick systems, but introduces time and space derivative source terms that can not be determined until the end of the time step. The space derivative source term can also lead to noise induced crashes under certain conditions where the real physical photon intensity differs strongly from a black body at the local material temperature. In this paper, we consider a difference formulation relative to the material temperature at the beginning of the time step, or in cases where an alternative temperature better describes the radiation field, that temperature. The result is a method where iterative solution of the material energy equation is efficient and noise induced crashes are avoided. We couple our generalized reference field scheme with an ad hoc interpolation of the space derivative source, resulting in an algorithm that produces the correct flux between zones as the physical system approaches the thick limit.

  12. Effect of Different Solar Radiation Data Sources on the Variation of Techno-Economic Feasibility of PV Power System

    Science.gov (United States)

    Alghoul, M. A.; Ali, Amer; Kannanaikal, F. V.; Amin, N.; Aljaafar, A. A.; Kadhim, Mohammed; Sopian, K.

    2017-11-01

    The aim of this study is to evaluate the variation in techno-economic feasibility of PV power system under different data sources of solar radiation. HOMER simulation tool is used to predict the techno-economic feasibility parameters of PV power system in Baghdad city, Iraq located at (33.3128° N, 44.3615° E) as a case study. Four data sources of solar radiation, different annual capacity shortages percentage (0, 2.5, 5, and 7.5), and wide range of daily load profile (10-100 kWh/day) are implemented. The analyzed parameters of the techno-economic feasibility are COE (/kWh), PV array power capacity (kW), PV electrical production (kWh/year), No. of batteries and battery lifetime (year). The main results of the study revealed the followings: (1) solar radiation from different data sources caused observed to significant variation in the values of the techno-economic feasibility parameters; therefore, careful attention must be paid to ensure the use of an accurate solar input data; (2) Average solar radiation from different data sources can be recommended as a reasonable input data; (3) it is observed that as the size and of PV power system increases, the effect of different data sources of solar radiation increases and causes significant variation in the values of the techno-economic feasibility parameters.

  13. SEALING SIMULATED LEAKS

    Energy Technology Data Exchange (ETDEWEB)

    Michael A. Romano

    2004-09-01

    This report details the testing equipment, procedures and results performed under Task 7.2 Sealing Simulated Leaks. In terms of our ability to seal leaks identified in the technical topical report, Analysis of Current Field Data, we were 100% successful. In regards to maintaining seal integrity after pigging operations we achieved varying degrees of success. Internal Corrosion defects proved to be the most resistant to the effects of pigging while External Corrosion proved to be the least resistant. Overall, with limitations, pressure activated sealant technology would be a viable option under the right circumstances.

  14. Sealing device for providing a seal in a turbomachine

    Energy Technology Data Exchange (ETDEWEB)

    Lacy, Benjamin Paul; Kottilingam, Srikanth Chandrudu; Porter, Christopher Donald; Schick, David Edward; Weber, David Wayne

    2016-08-16

    Sealing device for providing seals between adjacent components, and turbomachines utilizing such sealing devices, are provided. A sealing device includes a seal plate insertable between the adjacent components, the seal plate comprising a first face and an opposing second face. The sealing device further includes a plurality of pins extending from one of the first face or the second face, the plurality of pins configured to space the one of the first face or the second face from contact surfaces of the adjacent components.

  15. Building an open-source simulation platform of acoustic radiation force-based breast elastography.

    Science.gov (United States)

    Wang, Yu; Peng, Bo; Jiang, Jingfeng

    2017-03-07

    Ultrasound-based elastography including strain elastography, acoustic radiation force impulse (ARFI) imaging, point shear wave elastography and supersonic shear imaging (SSI) have been used to differentiate breast tumors among other clinical applications. The objective of this study is to extend a previously published virtual simulation platform built for ultrasound quasi-static breast elastography toward acoustic radiation force-based breast elastography. Consequently, the extended virtual breast elastography simulation platform can be used to validate image pixels with known underlying soft tissue properties (i.e. 'ground truth') in complex, heterogeneous media, enhancing confidence in elastographic image interpretations. The proposed virtual breast elastography system inherited four key components from the previously published virtual simulation platform: an ultrasound simulator (Field II), a mesh generator (Tetgen), a finite element solver (FEBio) and a visualization and data processing package (VTK). Using a simple message passing mechanism, functionalities have now been extended to acoustic radiation force-based elastography simulations. Examples involving three different numerical breast models with increasing complexity-one uniform model, one simple inclusion model and one virtual complex breast model derived from magnetic resonance imaging data, were used to demonstrate capabilities of this extended virtual platform. Overall, simulation results were compared with the published results. In the uniform model, the estimated shear wave speed (SWS) values were within 4% compared to the predetermined SWS values. In the simple inclusion and the complex breast models, SWS values of all hard inclusions in soft backgrounds were slightly underestimated, similar to what has been reported. The elastic contrast values and visual observation show that ARFI images have higher spatial resolution, while SSI images can provide higher inclusion-to-background contrast. In

  16. Development and transition of The Radiation, Interplanetary Shocks, and Coronal Sources (RISCS) Toolset

    Science.gov (United States)

    Zank, G. P.; Spann, J. F.

    2014-12-01

    We outline a plan to develop and transition a physics based predictive toolset called The Radiation, Interplanetary Shocks, and Coronal Sources (RISCS) to describe the interplanetary energetic particle and radiation environment throughout the inner heliosphere, including at the Earth. To forecast and "nowcast" the radiation environment requires the fusing of three components: 1) the ability to provide probabilities for incipient solar activity; 2) the use of these probabilities and daily coronal and solar wind observations to model the 3D spatial and temporal heliosphere, including magnetic field structure and transients, within 10 AU; and 3) the ability to model the acceleration and transport of energetic particles based on current and anticipated coronal and heliospheric conditions. We describe how to address 1) - 3) based on our existing, well developed, and validated codes and models. The goal of RISCS toolset is to provide an operational forecast and "nowcast" capability that will a) predict solar energetic particle (SEP) intensities; b) spectra for protons and heavy ions; c) predict maximum energies and their duration; d) SEP composition; e) cosmic ray intensities, and f) plasma parameters, including shock arrival times, strength and obliquity at any given heliospheric location and time. The toolset would have a 72 hour predicative capability, with associated probabilistic bounds, that would be updated hourly thereafter to improve the predicted event(s) and reduce the associated probability bounds. The RISCS toolset would be highly adaptable and portable, capable of running on a variety of platforms to accommodate various operational needs and requirements. The described transition plan is based on a well-established approach developed in the Earth Science discipline that ensures that the customer has a tool that meets their needs.

  17. Building an open-source simulation platform of acoustic radiation force-based breast elastography

    Science.gov (United States)

    Wang, Yu; Peng, Bo; Jiang, Jingfeng

    2017-03-01

    Ultrasound-based elastography including strain elastography, acoustic radiation force impulse (ARFI) imaging, point shear wave elastography and supersonic shear imaging (SSI) have been used to differentiate breast tumors among other clinical applications. The objective of this study is to extend a previously published virtual simulation platform built for ultrasound quasi-static breast elastography toward acoustic radiation force-based breast elastography. Consequently, the extended virtual breast elastography simulation platform can be used to validate image pixels with known underlying soft tissue properties (i.e. ‘ground truth’) in complex, heterogeneous media, enhancing confidence in elastographic image interpretations. The proposed virtual breast elastography system inherited four key components from the previously published virtual simulation platform: an ultrasound simulator (Field II), a mesh generator (Tetgen), a finite element solver (FEBio) and a visualization and data processing package (VTK). Using a simple message passing mechanism, functionalities have now been extended to acoustic radiation force-based elastography simulations. Examples involving three different numerical breast models with increasing complexity—one uniform model, one simple inclusion model and one virtual complex breast model derived from magnetic resonance imaging data, were used to demonstrate capabilities of this extended virtual platform. Overall, simulation results were compared with the published results. In the uniform model, the estimated shear wave speed (SWS) values were within 4% compared to the predetermined SWS values. In the simple inclusion and the complex breast models, SWS values of all hard inclusions in soft backgrounds were slightly underestimated, similar to what has been reported. The elastic contrast values and visual observation show that ARFI images have higher spatial resolution, while SSI images can provide higher inclusion-to-background contrast

  18. Leaf surface wax is a source of plant methane formation under UV radiation and in the presence of oxygen

    DEFF Research Database (Denmark)

    Bruhn, Dan; Mikkelsen, Teis Nørgaard; Rolsted, M. M. M.

    2014-01-01

    layer, and UV transmittance of the cuticle differs among plant species. In some species, the cuticle effectively absorbs and/or reflects UV radiation. Thus, pectin may not necessarily contribute substantially to the UV radiation-induced CH4 emission measured at surface level in all species. Here, we......The terrestrial vegetation is a source of UV radiation-induced aerobic methane (CH4) release to the atmosphere. Hitherto pectin, a plant structural component, has been considered as the most likely precursor for this CH4 release. However, most of the leaf pectin is situated below the surface wax...... investigated the potential of the leaf surface wax itself as a source of UV radiationinduced leaf aerobic CH4 formation. Isolated leaf surface wax emitted CH4 at substantial rates in response to UV radiation. This discovery has implications for how the phenomenon should be scaled to global levels. In relation...

  19. Spectral properties of the nonspherically decaying radiation generated by a rotating superluminal source.

    Science.gov (United States)

    Ardavan, Houshang; Ardavan, Arzhang; Singleton, John; Fasel, Joseph; Schmidt, Andrea

    2008-03-01

    The focusing of the radiation generated by a polarization current with a superluminally rotating distribution pattern is of a higher order in the plane of rotation than in other directions. Consequently, our previously published [J. Opt. Soc. Am. A24, 2443 (2007)] asymptotic approximation to the value of this field outside the equatorial plane breaks down as the line of sight approaches a direction normal to the rotation axis, i.e., is nonuniform with respect to the polar angle. Here we employ an alternative asymptotic expansion to show that, though having a rate of decay with frequency (mu) that is by a factor of order mu(2/3) slower, the equatorial radiation field has the same dependence on distance as the nonspherically decaying component of the generated field in other directions: It, too, diminishes as the inverse square root of the distance from its source. We also briefly discuss the relevance of these results to the giant pulses received from pulsars: The focused, nonspherically decaying pulses that arise from a superluminal polarization current in a highly magnetized plasma have a power-law spectrum (i.e., a flux density S infinity mu(alpha)) whose index (alpha) is given by one of the values -2/3, -2, -8/3, or -4.

  20. Development of short pulse laser driven micro-hohlraums as a source of EUV radiation

    Science.gov (United States)

    Krushelnick, Karl; Batson, Thomas; McKelvey, Andrew; Raymond, Anthony; Thomas, Alec; Yanovsky, Victor; Nees, John; Maksimchuk, Anatoly

    2015-11-01

    Experiments at large scale laser facilities such as NIF allow the radiativ properties of dens, high-temperature matter to be studied at previously unreachable regime, but are limited by cost and system availability. A scaled system using a short laser pulses and delivering energy to much smaller hohlraum could be capable of reaching comparable energy densities by depositing the energy in a much smaller volume before ablation of the wall material closes the cavit. The laser is tightl focused through the cavity and then expands to illuminate the wall. Experiments were performe using the Hercules Ti:Sapphire laser system at Michiga. Targets include cavities machined in bulk material using low laser power, and then shot in situ with a single full power pulse as well as micron scale pre-fabricate target. Spectral characteristics were measured using a soft X-ray spectromete, K-alpha x-ray imaging system and a filtered photo cathode array. Scalings of the radiation temperature were made for variations in the hohlraum cavit, the pulse duration as well as the focusing conditions. Proof of principle time resolved absorption spectroscopy experiments were also performe. These sources may allow opacity and atomic physics measurements with plasma an radiation temperatures comparable to much larger hohlraums, but with much higher repetition rate and in a university scale laboratory. We acknowledge funding from DTRA grant HDTRA1-11-1-0066.

  1. Estimate on external effective doses received by the Iranian population from environmental gamma radiation sources

    Energy Technology Data Exchange (ETDEWEB)

    Roozitalab, J.; Reza deevband, M.; Rastkhah, N. [National Radiation Protection Dept. Atomic Energy Organization (Iran, Islamic Republic of); Sohrabi, M. [Intenatinal atomic Energy Agency, Vienna (Austria)

    2006-07-01

    Concentration of natural radioactive materials, especially available U 238, Ra 226, Th 232, and K 40 in construction materials and soil, as well as absorb dose from cosmic rays, is the most important source of the people for effective doses from the environment radiation. In order to evaluate external effective dose, it has been carried out more than 1000 measurements in 36 cities by sensitive dosimeters to environmental gamma radiation for indoor and outdoor conditions in residential areas; which its results show that range of gamma exposure for inside of buildings in Iran is 8.7-20.5 {mu}R/h, and outdoor environments of different cities is 7.9-20.6 {mu}R/h, which their mean value are 14.33 and 12.62 {mu}R/h respectively. Meanwhile, it has been estimated that beam-absorbing ratio between indoor and outdoor in measured environments is 1.55, except contribution of cosmic rays. This studies show that average effective dose for each Iranian person from environmental gamma is 96.9 n Sv/h, and annually effective dose for every person is 0.848 mSv. (authors)

  2. Investigation on the use of Americium Oxide for Space Power Sources: Radiation Damage Studies

    Directory of Open Access Journals (Sweden)

    Wiss T.

    2017-01-01

    Several candidate Americium compounds will be investigated for chemical stability at high temperature and for self-irradiation damage. New thermo-electric converter materials containing actinides will be assessed, and a robust encapsulation designed. Safety analyses will be performed including launch explosion and re-entry accidents. The research will conclude in a conceptual design of a prototype power source. In the first part of this study, americium dioxide will be considered from the point of view of its chemical durability and of its behavior against radiation damage and helium formation, two aspects to be carefully investigated due to the high alpha-activity of the americium. Transmission electron Microscopy (TEM and helium thermal desorption spectrometry (TDS experiments will be described and results on aged (more than 30 years AmO2 reported. Some comparison with 238PuO2 based RTG’s will be discussed.

  3. The Advanced Photon Source: A national synchrotron radiation research facility at Argonne National Laboratory

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1995-10-01

    The vision of the APS sprang from prospective users, whose unflagging support the project has enjoyed throughout the decade it has taken to make this facility a reality. Perhaps the most extraordinary aspect of synchrotron radiation research, is the extensive and diverse scientific makeup of the user community. From this primordial soup of scientists exchanging ideas and information, come the collaborative and interdisciplinary accomplishments that no individual alone could produce. So, unlike the solitary Roentgen, scientists are engaged in a collective and dynamic enterprise with the potential to see and understand the structures of the most complex materials that nature or man can produce--and which underlie virtually all modern technologies. This booklet provides scientists and laymen alike with a sense of both the extraordinary history of x-rays and the knowledge they have produced, as well as the potential for future discovery contained in the APS--a source a million million times brighter than the Roentgen tube.

  4. Gravitational Radiation from Post-Newtonian Sources and Inspiralling Compact Binaries

    Science.gov (United States)

    Blanchet, Luc

    2014-02-01

    To be observed and analyzed by the network of gravitational wave detectors on ground (LIGO, VIRGO, etc.) and by the future detectors in space ( eLISA, etc.), inspiralling compact binaries — binary star systems composed of neutron stars and/or black holes in their late stage of evolution — require high-accuracy templates predicted by general relativity theory. The gravitational waves emitted by these very relativistic systems can be accurately modelled using a high-order post-Newtonian gravitational wave generation formalism. In this article, we present the current state of the art on post-Newtonian methods as applied to the dynamics and gravitational radiation of general matter sources (including the radiation reaction back onto the source) and inspiralling compact binaries. We describe the post-Newtonian equations of motion of compact binaries and the associated Lagrangian and Hamiltonian formalisms, paying attention to the self-field regularizations at work in the calculations. Several notions of innermost circular orbits are discussed. We estimate the accuracy of the post-Newtonian approximation and make a comparison with numerical computations of the gravitational self-force for compact binaries in the small mass ratio limit. The gravitational waveform and energy flux are obtained to high post-Newtonian order and the binary's orbital phase evolution is deduced from an energy balance argument. Some landmark results are given in the case of eccentric compact binaries — moving on quasi-elliptical orbits with non-negligible eccentricity. The spins of the two black holes play an important role in the definition of the gravitational wave templates. We investigate their imprint on the equations of motion and gravitational wave phasing up to high post-Newtonian order (restricting to spin-orbit effects which are linear in spins), and analyze the post-Newtonian spin precession equations as well as the induced precession of the orbital plane.

  5. Open-Source Radiation Exposure Extraction Engine (RE3) with Patient-Specific Outlier Detection.

    Science.gov (United States)

    Weisenthal, Samuel J; Folio, Les; Kovacs, William; Seff, Ari; Derderian, Vana; Summers, Ronald M; Yao, Jianhua

    2016-08-01

    We present an open-source, picture archiving and communication system (PACS)-integrated radiation exposure extraction engine (RE3) that provides study-, series-, and slice-specific data for automated monitoring of computed tomography (CT) radiation exposure. RE3 was built using open-source components and seamlessly integrates with the PACS. RE3 calculations of dose length product (DLP) from the Digital imaging and communications in medicine (DICOM) headers showed high agreement (R (2) = 0.99) with the vendor dose pages. For study-specific outlier detection, RE3 constructs robust, automatically updating multivariable regression models to predict DLP in the context of patient gender and age, scan length, water-equivalent diameter (D w), and scanned body volume (SBV). As proof of concept, the model was trained on 811 CT chest, abdomen + pelvis (CAP) exams and 29 outliers were detected. The continuous variables used in the outlier detection model were scan length (R (2)  = 0.45), D w (R (2) = 0.70), SBV (R (2) = 0.80), and age (R (2) = 0.01). The categorical variables were gender (male average 1182.7 ± 26.3 and female 1047.1 ± 26.9 mGy cm) and pediatric status (pediatric average 710.7 ± 73.6 mGy cm and adult 1134.5 ± 19.3 mGy cm).

  6. Radiative Transfer in a Translucent Cloud Illuminated by an Extended Background Source

    Science.gov (United States)

    Biganzoli, Davide; Potenza, Marco A. C.; Robberto, Massimo

    2017-05-01

    We discuss the radiative transfer theory for translucent clouds illuminated by an extended background source. First, we derive a rigorous solution based on the assumption that multiple scatterings produce an isotropic flux. Then we derive a more manageable analytic approximation showing that it nicely matches the results of the rigorous approach. To validate our model, we compare our predictions with accurate laboratory measurements for various types of well-characterized grains, including purely dielectric and strongly absorbing materials representative of astronomical icy and metallic grains, respectively, finding excellent agreement without the need to add free parameters. We use our model to explore the behavior of an astrophysical cloud illuminated by a diffuse source with dust grains having parameters typical of the classic ISM grains of Draine & Lee and protoplanetary disks, with an application to the dark silhouette disk 114-426 in Orion Nebula. We find that the scattering term modifies the transmitted radiation, both in terms of intensity (extinction) and shape (reddening) of the spectral distribution. In particular, for small optical thickness, our results show that scattering makes reddening almost negligible at visible wavelengths. Once the optical thickness increases enough and the probability of scattering events becomes close to or larger than 1, reddening becomes present but is appreciably modified with respect to the standard expression for line-of-sight absorption. Moreover, variations of the grain refractive index, in particular the amount of absorption, also play an important role in changing the shape of the spectral transmission curve, with dielectric grains showing the minimum amount of reddening.

  7. Gravitational Radiation from Post-Newtonian Sources and Inspiralling Compact Binaries

    Directory of Open Access Journals (Sweden)

    Luc Blanchet

    2014-02-01

    Full Text Available To be observed and analyzed by the network of gravitational wave detectors on ground (LIGO, VIRGO, etc. and by the future detectors in space (eLISA, etc., inspiralling compact binaries -- binary star systems composed of neutron stars and/or black holes in their late stage of evolution -- require high-accuracy templates predicted by general relativity theory. The gravitational waves emitted by these very relativistic systems can be accurately modelled using a high-order post-Newtonian gravitational wave generation formalism. In this article, we present the current state of the art on post-Newtonian methods as applied to the dynamics and gravitational radiation of general matter sources (including the radiation reaction back onto the source and inspiralling compact binaries. We describe the post-Newtonian equations of motion of compact binaries and the associated Lagrangian and Hamiltonian formalisms, paying attention to the self-field regularizations at work in the calculations. Several notions of innermost circular orbits are discussed. We estimate the accuracy of the post-Newtonian approximation and make a comparison with numerical computations of the gravitational self-force for compact binaries in the small mass ratio limit. The gravitational waveform and energy flux are obtained to high post-Newtonian order and the binary's orbital phase evolution is deduced from an energy balance argument. Some landmark results are given in the case of eccentric compact binaries -- moving on quasi-elliptical orbits with non-negligible eccentricity. The spins of the two black holes play an important role in the definition of the gravitational wave templates. We investigate their imprint on the equations of motion and gravitational wave phasing up to high post-Newtonian order (restricting to spin-orbit effects which are linear in spins, and analyze the post-Newtonian spin precession equations as well as the induced precession of the orbital plane.

  8. A compact laparoscope type radiation source for the pin-point cancer treatment using a femtosecond laser

    Science.gov (United States)

    Kawashima, N.; Muramatsu, H.; Ueda, M.; Yanagimoto, C.; Miyazawa, M.; Kajiwara, E.

    2012-02-01

    Focusing a femto-second laser (1 mJ/pulse repetition 1 kHz) on a special tape, a strong radiation consisting of the electron beam of ~ 200 keV and X-rays of ~ 6.4 keV (5 %) has been generated. It has been verified that the radiation source is sufficient to kill the tumor cells and the DNA laddering structure in the in-vivo test is obtained. More test implanting the tumor under the skin of mouse and irradiating the laser-generated radiation, we have shown the radiation has a clear powerful therapeutic capability. For about 80 % of mice irradiated, their tumor disappeared. For further clinical test use, a compact laparoscope-type unit mounted on an articulated arm has been constructed and it can generate the necessary amount of the radiation dose.

  9. Ingestion resistant seal assembly

    Science.gov (United States)

    Little, David A [Chuluota, FL

    2011-12-13

    A seal assembly limits gas leakage from a hot gas path to one or more disc cavities in a gas turbine engine. The seal assembly includes a seal apparatus associated with a blade structure including a row of airfoils. The seal apparatus includes an annular inner shroud associated with adjacent stationary components, a wing member, and a first wing flange. The wing member extends axially from the blade structure toward the annular inner shroud. The first wing flange extends radially outwardly from the wing member toward the annular inner shroud. A plurality of regions including one or more recirculation zones are defined between the blade structure and the annular inner shroud that recirculate working gas therein back toward the hot gas path.

  10. Fur seal investigations, 1966

    Data.gov (United States)

    US Fish and Wildlife Service, Department of the Interior — Annually a report is made on the fur seal investigations carried on by the Bureau of Commercial Fisheries on the Pribilof Islands and at sea. Investigations on the...

  11. Spotted Seal Distribution Map

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — This dataset contains GIS layers that depict the known spatial distributions (i.e., ranges) and reported breeding areas of spotted seals (Phoca largha). It was...

  12. Turbine seal assembly

    Science.gov (United States)

    Little, David A.

    2013-04-16

    A seal assembly that limits gas leakage from a hot gas path to one or more disc cavities in a turbine engine. The seal assembly includes a seal apparatus that limits gas leakage from the hot gas path to a respective one of the disc cavities. The seal apparatus comprises a plurality of blade members rotatable with a blade structure. The blade members are associated with the blade structure and extend toward adjacent stationary components. Each blade member includes a leading edge and a trailing edge, the leading edge of each blade member being located circumferentially in front of the blade member's corresponding trailing edge in a direction of rotation of the turbine rotor. The blade members are arranged such that a space having a component in a circumferential direction is defined between adjacent circumferentially spaced blade members.

  13. Bearded Seal Distribution Map

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — This dataset contains GIS layers that depict the known spatial distributions (i.e., ranges) of the two subspecies of bearded seals (Erignathus barbatus). It was...

  14. Ringed Seal Distribution Map

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — This dataset contains GIS layers that depict the known spatial distributions (i.e., ranges) of the five subspecies of ringed seals (Phoca hispida). It was produced...

  15. Damping Seals for Turbomachinery

    Science.gov (United States)

    Von Pragenau, G. L.

    1984-01-01

    Seals with rough surfaces proposed for stabilizing shaft motion and preventing leakage along shaft in machines such as turbopumps. Applicable to turbomachinery with speed limits raised and bearing life extended, avoiding costly shutdowns.

  16. Skull morphometrics of male Subantarctic fur seals ( Arctocephalus ...

    African Journals Online (AJOL)

    Skull morphometrics of two populations of Subantarctic fur seal (Arctocephalus tropicalis) were compared in order to identify possible geographic variation as an indicator of gene flow between the populations, as well as a potential tool to identify the source of vagrant seals. Nineteen metric variables were recorded from ...

  17. On beam shaping of the field radiated by a line source coupled to finite or infinite photonic crystals.

    Science.gov (United States)

    Ceccuzzi, Silvio; Jandieri, Vakhtang; Baccarelli, Paolo; Ponti, Cristina; Schettini, Giuseppe

    2016-04-01

    Comparison of the beam-shaping effect of a field radiated by a line source, when an ideal infinite structure constituted by two photonic crystals and an actual finite one are considered, has been carried out by means of two different methods. The lattice sums technique combined with the generalized reflection matrix method is used to rigorously investigate the radiation from the infinite photonic crystals, whereas radiation from crystals composed of a finite number of rods along the layers is analyzed using the cylindrical-wave approach. A directive radiation is observed with the line source embedded in the structure. With an increased separation distance between the crystals, a significant edge diffraction appears that provides the main radiation mechanism in the finite layout. Suitable absorbers are implemented to reduce the above-mentioned diffraction and the reflections at the boundaries, thus obtaining good agreement between radiation patterns of a localized line source coupled to finite and infinite photonic crystals, when the number of periods of the finite structure is properly chosen.

  18. Assessment of TID Effect of FRAM Memory Cell Under Electron, X-Ray, and Co- 60 gamma Ray Radiation Sources

    Science.gov (United States)

    Shen, Jingyu; Li, Wei; Zhang, Yuanbin

    2017-03-01

    This paper investigates the total ionizing dose (TID) effect of the memory cell of the ferroelectric random access memory (FRAM) under electron, X-ray, and Co-60 γ ray radiation sources. An electron accelerator and an X-ray microbeam from synchrotron, which are used to simulate the given radiation environments, offer local irradiation on the FRAM memory cell. In addition, the Co-60 γ ray source provides global irradiation on the full chip of FRAM. The FRAM memory cell is proved to have a lower failure threshold for TID effect than the ferroelectric thin-film capacitor due to the performance degradation of nMOS transistor in memory cell. The failure phenomenon is studied according to the experimental results of different radiation sources, and the failure mechanism is discussed based on the technology and the characteristics of FRAM memory cell in circuit-level. The difference of device performance is also analyzed for electron irradiation and X-ray irradiation.

  19. Apartment Compartmentalization With an Aerosol-Based Sealing Process

    Energy Technology Data Exchange (ETDEWEB)

    Maxwell, S. [Consortium for Advanced Residential Buildings, Norwalk, CT (United States); Berger, D. [Consortium for Advanced Residential Buildings, Norwalk, CT (United States); Harrington, C. [Consortium for Advanced Residential Buildings, Norwalk, CT (United States)

    2015-03-01

    Air sealing of building enclosures is a difficult and time-consuming process. Current methods in new construction require laborers to physically locate small and sometimes large holes in multiple assemblies and then manually seal each of them. The innovation demonstrated under this research study was the automated air sealing and compartmentalization of buildings through the use of an aerosolized sealant, developed by the Western Cooling Efficiency Center at University of California Davis. CARB sought to demonstrate this new technology application in a multifamily building in Queens, NY. The effectiveness of the sealing process was evaluated by three methods: air leakage testing of overall apartment before and after sealing, point-source testing of individual leaks, and pressure measurements in the walls of the target apartment during sealing.

  20. A robust hypothesis test for the sensitive detection of constant speed radiation moving sources

    Energy Technology Data Exchange (ETDEWEB)

    Dumazert, Jonathan, E-mail: jonathan.dumazert@cea.fr [CEA, LIST, Laboratoire Capteurs Architectures Electroniques, 91191 Gif-sur-Yvette (France); Coulon, Romain; Kondrasovs, Vladimir; Boudergui, Karim; Moline, Yoann; Sannié, Guillaume; Gameiro, Jordan; Normand, Stéphane [CEA, LIST, Laboratoire Capteurs Architectures Electroniques, 91191 Gif-sur-Yvette (France); Méchin, Laurence [CNRS, UCBN, Groupe de Recherche en Informatique, Image, Automatique et Instrumentation de Caen, 14050 Caen (France)

    2015-09-21

    Radiation Portal Monitors are deployed in linear networks to detect radiological material in motion. As a complement to single and multichannel detection algorithms, inefficient under too low signal-to-noise ratios, temporal correlation algorithms have been introduced. Test hypothesis methods based on empirically estimated mean and variance of the signals delivered by the different channels have shown significant gain in terms of a tradeoff between detection sensitivity and false alarm probability. This paper discloses the concept of a new hypothesis test for temporal correlation detection methods, taking advantage of the Poisson nature of the registered counting signals, and establishes a benchmark between this test and its empirical counterpart. The simulation study validates that in the four relevant configurations of a pedestrian source carrier under respectively high and low count rate radioactive backgrounds, and a vehicle source carrier under the same respectively high and low count rate radioactive backgrounds, the newly introduced hypothesis test ensures a significantly improved compromise between sensitivity and false alarm. It also guarantees that the optimal coverage factor for this compromise remains stable regardless of signal-to-noise ratio variations between 2 and 0.8, therefore allowing the final user to parametrize the test with the sole prior knowledge of background amplitude.

  1. Hypothesis tests for the detection of constant speed radiation moving sources

    Energy Technology Data Exchange (ETDEWEB)

    Dumazert, Jonathan; Coulon, Romain; Kondrasovs, Vladimir; Boudergui, Karim; Sannie, Guillaume; Gameiro, Jordan; Normand, Stephane [CEA, LIST, Laboratoire Capteurs Architectures Electroniques, 99 Gif-sur-Yvette, (France); Mechin, Laurence [CNRS, UCBN, Groupe de Recherche en Informatique, Image, Automatique et Instrumentation de Caen, 4050 Caen, (France)

    2015-07-01

    Radiation Portal Monitors are deployed in linear network to detect radiological material in motion. As a complement to single and multichannel detection algorithms, inefficient under too low signal to noise ratios, temporal correlation algorithms have been introduced. Test hypothesis methods based on empirically estimated mean and variance of the signals delivered by the different channels have shown significant gain in terms of a tradeoff between detection sensitivity and false alarm probability. This paper discloses the concept of a new hypothesis test for temporal correlation detection methods, taking advantage of the Poisson nature of the registered counting signals, and establishes a benchmark between this test and its empirical counterpart. The simulation study validates that in the four relevant configurations of a pedestrian source carrier under respectively high and low count rate radioactive background, and a vehicle source carrier under the same respectively high and low count rate radioactive background, the newly introduced hypothesis test ensures a significantly improved compromise between sensitivity and false alarm, while guaranteeing the stability of its optimization parameter regardless of signal to noise ratio variations between 2 to 0.8. (authors)

  2. Contribution to a critical evaluation of radioprotection by means of retrospective analysis of doses associated with the work with non-sealed Iodine-131 sources

    CERN Document Server

    Carneiro, J C G G

    1998-01-01

    The present work consists of the dose reconstruction from internal contamination received by workers occupationally exposed to Iodine-131, along the years 1981 to 1994. The group of workers selected to perform this research work in the Instituto de Pesquisas Energeticas e Nucleares which is responsible for irradiated target processing, molecules labeling and distribution of radioactive material. The data analysis was performed using the urinalysis data, historical records of the individual workers exposure to radiation and records from the area radiation protection supervision. This information is used to estimate the main incorporation path, to establish an intake model and to estimate the retrospective effective dose. Using the urinalysis data it was verified that the workers, along the years, is subject to chronic intakes as well as acute intake of iodine-131. The results related to the contribution of each type of exposure were analysed separately and later added to obtain the total effective internal dos...

  3. Leaf surface wax is a source of plant methane formation under UV radiation and in the presence of oxygen.

    Science.gov (United States)

    Bruhn, D; Mikkelsen, T N; Rolsted, M M M; Egsgaard, H; Ambus, P

    2014-03-01

    The terrestrial vegetation is a source of UV radiation-induced aerobic methane (CH4 ) release to the atmosphere. Hitherto pectin, a plant structural component, has been considered as the most likely precursor for this CH4 release. However, most of the leaf pectin is situated below the surface wax layer, and UV transmittance of the cuticle differs among plant species. In some species, the cuticle effectively absorbs and/or reflects UV radiation. Thus, pectin may not necessarily contribute substantially to the UV radiation-induced CH4 emission measured at surface level in all species. Here, we investigated the potential of the leaf surface wax itself as a source of UV radiation-induced leaf aerobic CH4 formation. Isolated leaf surface wax emitted CH4 at substantial rates in response to UV radiation. This discovery has implications for how the phenomenon should be scaled to global levels. In relation to this, we demonstrated that the UV radiation-induced CH4 emission is independent of leaf area index above unity. Further, we observed that the presence of O2 in the atmosphere was necessary for achieving the highest rates of CH4 emission. Methane formation from leaf surface wax is supposedly a two-step process initiated by a photolytic rearrangement reaction of the major component followed by an α-cleavage of the generated ketone. © 2014 German Botanical Society and The Royal Botanical Society of the Netherlands.

  4. Carbonaceous aerosols and pollutants over Delhi urban environment: Temporal evolution, source apportionment and radiative forcing

    Energy Technology Data Exchange (ETDEWEB)

    Bisht, D.S. [Indian Institute of Tropical Meteorology, New Delhi (India); Dumka, U.C., E-mail: dumka@aries.res.in [Aryabhatta Research Institute of Observational Sciences, Nainital (India); Kaskaoutis, D.G. [School of Natural Sciences, Shiv Nadar University, Tehsil Dadri (India); Pipal, A.S. [Department of Chemistry, Savitribai Phule Pune University, Pune (India); Srivastava, A.K. [Indian Institute of Tropical Meteorology, New Delhi (India); Soni, V.K.; Attri, S.D.; Sateesh, M. [India Meteorology Department, Lodhi Road, New Delhi (India); Tiwari, S. [Indian Institute of Tropical Meteorology, New Delhi (India)

    2015-07-15

    Particulate matter (PM{sub 2.5}) samples were collected over Delhi, India during January to December 2012 and analysed for carbonaceous aerosols and inorganic ions (SO{sub 4}{sup 2−} and NO{sub 3}{sup −}) in order to examine variations in atmospheric chemistry, combustion sources and influence of long-range transport. The PM{sub 2.5} samples are measured (offline) via medium volume air samplers and analysed gravimetrically for carbonaceous (organic carbon, OC; elemental carbon, EC) aerosols and inorganic ions (SO{sub 4}{sup 2−} and NO{sub 3}{sup −}). Furthermore, continuous (online) measurements of PM{sub 2.5} (via Beta-attenuation analyser), black carbon (BC) mass concentration (via Magee scientific Aethalometer) and carbon monoxide (via CO-analyser) are carried out. PM{sub 2.5} (online) range from 18.2 to 500.6 μg m{sup −3} (annual mean of 124.6 ± 87.9 μg m{sup −3}) exhibiting higher night-time (129.4 μg m{sup −3}) than daytime (103.8 μg m{sup −3}) concentrations. The online concentrations are 38% and 28% lower than the offline during night and day, respectively. In general, larger night-time concentrations are found for the BC, OC, NO{sub 3}{sup −}and SO{sub 4}{sup 2−}, which are seasonally dependent with larger differences during late post-monsoon and winter. The high correlation (R{sup 2} = 0.74) between OC and EC along with the OC/EC of 7.09 (day time) and 4.55 (night-time), suggest significant influence of biomass-burning emissions (burning of wood and agricultural waste) as well as secondary organic aerosol formation during daytime. Concentrated weighted trajectory (CWT) analysis reveals that the potential sources for the carbonaceous aerosols and pollutants are local emissions within the urban environment and transported smoke from agricultural burning in northwest India during post-monsoon. BC radiative forcing estimates result in very high atmospheric heating rates (~ 1.8–2.0 K day{sup −1}) due to agricultural burning effects

  5. RELATION OF DAILY PERIODS OF VLF RADIATION WITH X-RAY SOURCES

    Directory of Open Access Journals (Sweden)

    Druzhin, G.I.

    2016-11-01

    Full Text Available Spectral analysis of electromagnetic noise radiation in the VLF range at three fixed frequencies for the period from 1997 to 2015 have been carried out. Periodograms with diurnal components associated with the periods of the Earth rotation relatively the Sun and the stars have been obtained. It has been shown that the Sun х-radiation and the galaxy х-radiation affect daily variations of VLF radiation.

  6. Terahertz Coherent Synchrotron Radiation from Femtosecond Laser Modulation of the Electron Beam at the Advanced Light Source

    CERN Document Server

    Byrd, John; Martin, Michael C; Robin, David; Sannibale, Fernando; Schönlein, Robert W; Zholents, Alexander; Zolotorev, Max S

    2005-01-01

    At the Advanced Light Source (ALS), the "femtoslicing" beamline is in operation since 1999 for the production of x-ray synchrotron radiation pulses with femtosecond duration. The mechanism used for generating the short x-ray pulses induces at the same time temporary structures in the electron bunch longitudinal distribution with very short characteristic length. Such structures emit intense coherent synchrotron radiation (CSR) in the terahertz frequency range. This CSR, whose measured intensity is routinely used as a diagnostics for the tune-up of the femtoslicing experiments, represents a potential source of terahertz radiation with very interesting features. Several measurements have been performed for its characterization and in this paper an updated description of the experimental results and of their interpretation is presented.

  7. Taper-seal type metal sealing system and available applications

    Science.gov (United States)

    Kurokouchi, Satoshi; Okabe, Masayuki; Morita, Shinsaku

    2001-01-01

    A conventional disk (flat ring) gasket for ConFlat ® sealing system has been commonly applied to commercially available equipments for ultrahigh vacuum systems. However, its large redundant part which wastes the tightening force makes its handling and seal reliability problematic. We examine a taper-seal type gasket, which is newly designed to improve the inefficiency of ConFlat mechanism using conventional disk gaskets. It is remarked that the obtained seal area on a taper-seal type gasket is 1.6˜3.7 times larger than that of a conventional disk gasket. Our numencal results on stress distributions in a tightened gasket indicate that taper-seal gasket realizes highly stable seal pressure even under a lower tightening torque. High sealing reliability is thus achieved as expected which is mainly due to the wide seal area and stable seal pressure realized even for rather hard gasket material. Taper-seal type gasket also has some practical advantages. The most important of them may be that it enables to construct new edgeless metal sealing systems without a welded heavy flange. Here, edgeless sealing systems are composed of highly flexible incorporating viewports, bellows, feedthroughs, and blank-off covers, as well as any other conventional vacuum components.

  8. 76 FR 82077 - Food Ingredients and Sources of Radiation Listed or Approved for Use in the Production of Meat...

    Science.gov (United States)

    2011-12-30

    ... and Sources of Radiation Listed or Approved for Use in the Production of Meat and Poultry Products... listed or approved for use in the production of meat and poultry products. DATES: December 30, 2011... Meat and Poultry Products'' (64 FR 72168). Among other things, this final rule consolidated various...

  9. Radon Adsorbed in Activated Charcoal--A Simple and Safe Radiation Source for Teaching Practical Radioactivity in Schools and Colleges

    Science.gov (United States)

    Al-Azmi, Darwish; Mustapha, Amidu O.; Karunakara, N.

    2012-01-01

    Simple procedures for teaching practical radioactivity are presented in a way that attracts students' attention and does not make them apprehensive about their safety. The radiation source is derived from the natural environment. It is based on the radioactivity of radon, a ubiquitous inert gas, and the adsorptive property of activated charcoal.…

  10. Blackbody source in the -50 to +200 degrees C range for the calibration of radiometers and radiation thermometers.

    Science.gov (United States)

    Quinn, T J; Martin, J E

    1991-11-01

    A high-accuracy, large-aperture calibration source for radiometers and infrared radiation pyrometers operating in the range from -50 to +200 degrees C is described. It is shown that by means of reflecting surfaces inside the blackbody the requirements for temperature uniformity can be substantially relaxed while high accuracy in the characterization of the effectivet emperaturei s maintained.

  11. Seal system with integral detector

    Science.gov (United States)

    Fiarman, Sidney

    1985-01-01

    There is disclosed a seal system for materials where security is of the essence, such as nuclear materials, which is tamper-indicating, which indicates changes in environmental conditions that evidence attempts to by-pass the seal, which is unique and cost effective, said seal system comprised of a seal where an optical signal is transmitted through a loop, with a detector to read said signal, and one or more additional detectors designed to detect environmental changes, these detectors being operatively associated with the seal so that detection of a break in the optical signal or detection of environmental changes will cause an observable change in the seal.

  12. Measurement of the Dispersion of Radiation from a Steady Cosmological Source

    Science.gov (United States)

    Lieu, Richard; Duan, Lingze; Kibble, T. W. B.

    2013-11-01

    The "missing baryons" of the near universe are believed to be principally in a partially ionized state. Although passing electromagnetic waves are dispersed by the plasma, the effect has hitherto not been utilized as a means of detection because it is generally believed that a successful observation requires the background source to be highly variable, i.e., the class of sources that could potentially deliver a verdict is limited. We argue in two stages that this condition is not necessary. First, by modeling the fluctuations on macroscopic scales as interference between wave packets, we show that, in accordance with the ideas advanced by Einstein in 1917, both the behavior of photons as bosons (i.e., the intensity variance has contributions from Poisson and phase noise) and the van-Cittert-Zernike theorem are a consequence of wave-particle duality. Nevertheless, we then point out that, in general, the variance on some macroscopic timescale τ consists of (1) a main contributing term vprop1/τ, plus (2) a small negative term vprop1/τ2 due to the finite size of the wave packets. If the radiation passes through a dispersive medium, this size will be enlarged well beyond its vacuum minimum value of Δt ≈ 1/Δν, leading to a more negative (2) term (while (1) remains unchanged), and hence a suppression of the variance wrt the vacuum scenario. The phenomenon, which is typically at a few parts in 105 level, enables one to measure cosmological dispersion in principle. Signal-to-noise estimates, along with systematic issues and how to overcome them, will be presented.

  13. Detection of embedded radiation sources using temporal variation of gamma spectral data.

    Energy Technology Data Exchange (ETDEWEB)

    Shokair, Isaac R.

    2011-09-01

    Conventional full spectrum gamma spectroscopic analysis has the objective of quantitative identification of all the isotopes present in a measurement. For low energy resolution detectors, when photopeaks alone are not sufficient for complete isotopic identification, such analysis requires template spectra for all the isotopes present in the measurement. When many isotopes are present it is difficult to make the correct identification and this process often requires many trial solutions by highly skilled spectroscopists. This report investigates the potential of a new analysis method which uses spatial/temporal information from multiple low energy resolution measurements to test the hypothesis of the presence of a target spectrum of interest in these measurements without the need to identify all the other isotopes present. This method is referred to as targeted principal component analysis (TPCA). For radiation portal monitor applications, multiple measurements of gamma spectra are taken at equally spaced time increments as a vehicle passes through the portal and the TPCA method is directly applicable to this type of measurement. In this report we describe the method and investigate its application to the problem of detection of a radioactive localized source that is embedded in a distributed source in the presence of an ambient background. Examples using simulated spectral measurements indicate that this method works very well and has the potential for automated analysis for RPM applications. This method is also expected to work well for isotopic detection in the presence of spectrally and spatially varying backgrounds as a result of vehicle-induced background suppression. Further work is needed to include effects of shielding, to understand detection limits, setting of thresholds, and to estimate false positive probability.

  14. Analysis of radiation environmental safety for China's Spallation Neutron Source (CSNS)

    Science.gov (United States)

    Wang, Qing-Bin; Wu, Qing-Biao; Ma, Zhong-Jian; Zhang, Qing-Jiang; Li, Nan; Wu, Jing-Min; Liu, Jian; Zhang, Gang

    2010-07-01

    The China Spallation Neutron Source (CSNS) is going to be located in Dalang Town, Dongguan City in the Guangdong Province. In this paper we report the results of the parameters related with environment safety based on experiential calculations and Monte Carlo simulations. The main project of the accelerator is an under ground construction. On top there is a 0.5 m concrete and 5.0 m soil covering for shielding, which can reduce the dose out of the tunnel's top down to 0.2 μSv/h. For the residents on the boundary of the CSNS, the dose produced by skyshine, which is caused by the penetrated radiation leaking from the top of the accelerator, is no more than 0.68 μSv/a. When CSNS is operating normally, the maximal annual effective dose due to the emission of gas from the tunnel is 2.40×10-3 mSv/a to the public adult, and 2.29×10-3 mSv/a to a child, both values are two orders of magnitude less than the limiting value for control and management. CSNS may give rise to an activation of the soil and groundwater in the nearest tunnels, where the main productions are 3H, 7Be, 22Na, 54Mn, etc. But the specific activity is less than the exempt specific activity in the national standard GB13376-92. So it is safe to say that the environmental impact caused by the activation of soil and groundwater is insignificant. To sum up, for CSNS, as a powerful neutron source device, driven by a high-energy high-current proton accelerator, a lot of potential factors affecting the environment exist. However, as long as effective shieldings for protection are adopted and strict rules are drafted, the environmental impact can be kept under control within the limits of the national standard.

  15. Advisory Committee on human radiation experiments. Final report, Supplemental Volume 2. Sources and documentation

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1995-01-01

    This volume and its appendixes supplement the Advisory Committee`s final report by reporting how we went about looking for information concerning human radiation experiments and intentional releases, a description of what we found and where we found it, and a finding aid for the information that we collected. This volume begins with an overview of federal records, including general descriptions of the types of records that have been useful and how the federal government handles these records. This is followed by an agency-by-agency account of the discovery process and descriptions of the records reviewed, together with instructions on how to obtain further information from those agencies. There is also a description of other sources of information that have been important, including institutional records, print resources, and nonprint media and interviews. The third part contains brief accounts of ACHRE`s two major contemporary survey projects (these are described in greater detail in the final report and another supplemental volume) and other research activities. The final section describes how the ACHRE information-nation collections were managed and the records that ACHRE created in the course of its work; this constitutes a general finding aid for the materials deposited with the National Archives. The appendices provide brief references to federal records reviewed, descriptions of the accessions that comprise the ACHRE Research Document Collection, and descriptions of the documents selected for individual treatment. Also included are an account of the documentation available for ACHRE meetings, brief abstracts of the almost 4,000 experiments individually described by ACHRE staff, a full bibliography of secondary sources used, and other information.

  16. Contributions of projected land use to global radiative forcing ascribed to local sources

    Science.gov (United States)

    Ward, D. S.; Mahowald, N. M.; Kloster, S.

    2013-12-01

    With global demand for food expected to dramatically increase and put additional pressures on natural lands, there is a need to understand the environmental impacts of land use and land cover change (LULCC). Previous studies have shown that the magnitude and even the sign of the radiative forcing (RF) of biogeophysical effects from LULCC depends on the latitude and forest ecology of the disturbed region. Here we ascribe the contributions to the global RF by land-use related anthropogenic activities to their local sources, organized on a grid of 1.9 degrees latitude by 2.5 degrees longitude. We use RF estimates for the year 2100, using five future LULCC projections, computed from simulations with the National Center for Atmospheric Research Community Land Model and Community Atmosphere Models and additional offline analyses. Our definition of the LULCC RF includes changes to terrestrial carbon storage, methane and nitrous oxide emissions, atmospheric chemistry, aerosol emissions, and surface albedo. We ascribe the RF to gridded locations based on LULCC-related emissions of relevant trace gases and aerosols, including emissions from fires. We find that the largest contributions to the global RF in year 2100 from LULCC originate in the tropics for all future scenarios. In fact, LULCC is the largest tropical source of anthropogenic RF. The LULCC RF in the tropics is dominated by emissions of CO2 from deforestation and methane emissions from livestock and soils. Land surface albedo change is rarely the dominant forcing agent in any of the future LULCC projections, at any location. By combining the five future scenarios we find that deforested area at a specific tropical location can be used to predict the contribution to global RF from LULCC at that location (the relationship does not hold as well in the extratropics). This information could support global efforts like REDD (Reducing Emissions from Deforestation and Forest Degradation), that aim to reduce greenhouse gas

  17. HMSRP Hawaiian Monk Seal Master Identification Records (seal)

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — This data set contains records of all individually identified Hawaiian monk seals since 1981. These seals were identified by PSD personnel and cooperating scientists...

  18. Investigation of gamma-ray fingerprint identifying mechanism for the types of radiation sources

    CERN Document Server

    Liu Su Ping; Gu Dang Chang; Gong-Jian; Hao Fan Hua; Hu Guang Chun

    2002-01-01

    Radiation fingerprints sometimes can be used to label and identify the radiation resources. For instance, in a future nuclear reduction treaty that requires verification of irreversible dismantling of reduced nuclear warheads, the radiation fingerprints of nuclear warheads are expected to play a key role in labelling and identifying the reduced warheads. It would promote the development of nuclear warheads deep-cuts verification technologies if authors start right now some investigations on the issues related to the radiation fingerprints. The author dedicated to the investigation of gamma-ray fingerprint identifying mechanism for the types of radiation resources. The purpose of the identifying mechanism investigation is to find a credible way to tell whether any two gamma-ray spectral fingerprints that are under comparison are radiated from the same resource. The authors created the spectrum pattern comparison (SPC) to study the comparability of the two radiation fingerprints. Guided by the principle of SPC,...

  19. The electron-cyclotron maser instability as a source of plasma radiation. [Solar radio bursts

    Science.gov (United States)

    Winglee, R. M.; Dulk, G. A.

    1986-01-01

    The generation of continuum bursts from the sun at dm and m wavelengths (in particular, type IV bursts) via the electron-cyclotron-maser instability is examined. The maser instability can be driven by an electron distribution with either a loss-cone anisotropy or a peak at large pitch angles. For omega(p)/Omega(e) much greater than 1, the maser emission is produced by electrons interacting through a harmonic (cyclotron) resonance and is electrostatic, being in the upper hybrid mode at frequencies approximately equal to omega(p). Coalescence processes are required to convert the electrostatic waves into transverse radiation which can escape from the source region. Whether the resultant spectrum is nearly a smooth continuum or has a zebra-stripe pattern (both of which occur in type IV bursts) depends on the form of the electron distribution, inhomogeneities in the density and magnetic field, and whether the maser reaches saturation. For at least the case of some type IV dm bursts with fine structure, comparison with observations seems to indicate that the electrons producing the emission are more likely to have a loss-cone distribution, and that the maser instability is not at saturation.

  20. Studies of longitudinal profile of electron bunches and impedance measurements at Indus-2 synchrotron radiation source

    Energy Technology Data Exchange (ETDEWEB)

    Garg, Akash Deep, E-mail: akash-deep@rrcat.gov.in [Beam Diagnostics Section (BDS), Indus Operations, Beam Dynamics and Diagnostics Division (IOBDD), Raja Ramanna Centre for Advanced Technology, Indore 452 013, M.P. (India); Homi Bhabha National Institute (HBNI) at Raja Ramanna Centre for Advanced Technology, Indore (India); Yadav, S.; Kumar, Mukesh; Shrivastava, B.B.; Karnewar, A.K.; Ojha, A.; Puntambekar, T.A. [Beam Diagnostics Section (BDS), Indus Operations, Beam Dynamics and Diagnostics Division (IOBDD), Raja Ramanna Centre for Advanced Technology, Indore 452 013, M.P. (India)

    2016-04-01

    Indus-2 is a 3rd generation synchrotron radiation source at the Raja Ramanna Centre for Advanced Technology (RRCAT) in India. We study the longitudinal profile of electrons in Indus-2 by using dual sweep synchroscan streak camera at visible diagnostic beamline. In this paper, the longitudinal profiles of electron bunch are analyzed by filling beam current in a single bunch mode. These studies are carried at injection energy (550 MeV) and at ramped beam energy (2.5 GeV). The effects of the wakefield generated interactions between the circulating electrons and the surrounding vacuum chamber are analyzed in terms of measured effects on longitudinal beam distribution. The impedance of the storage ring is obtained by fitting the solutions of Haissinski equation to the measured bunch lengthening with different impedance models. The impedance of storage ring obtained by a series R+L impedance model indicates a resistance (R) of 1350±125 Ω, an inductance (L) of 180±25 nH and broadband impedance of 2.69 Ω. These results are also compared with the values obtained from measured synchronous phase advancing and scaling laws. These studies are very useful in better understanding and control of the electromagnetic interactions.

  1. A method for the temperature calibration of an infrared camera using water as a radiative source.

    Science.gov (United States)

    Bower, S M; Kou, J; Saylor, J R

    2009-09-01

    Presented here is an effective low-cost method for the temperature calibration of infrared cameras, for applications in the 0-100 degrees C range. The calibration of image gray level intensity to temperature is achieved by imaging an upwelling flow of water, the temperature of which is measured with a thermistor probe. The upwelling flow is created by a diffuser located below the water surface of a constant temperature water bath. The thermistor probe is kept immediately below the surface, and the distance from the diffuser outlet to the surface is adjusted so that the deformation of the water surface on account of the flow is small, yet the difference between the surface temperature seen by the camera and the bulk temperature measured by the thermistor is also small. The benefit of this method compared to typical calibration procedures is that, without sacrificing the quality of the calibration, relatively expensive commercial blackbodies are replaced by water as the radiative source (epsilon approximately 0.98 for the wavelengths considered here). A heat transfer analysis is provided, which improves the accuracy of the calibration method and also provides the user with guidance to further increases in accuracy of the method.

  2. An isotopic analysis of ionising radiation as a source of sulphuric acid

    Directory of Open Access Journals (Sweden)

    M. B. Enghoff

    2012-06-01

    Full Text Available Sulphuric acid is an important factor in aerosol nucleation and growth. It has been shown that ions enhance the formation of sulphuric acid aerosols, but the exact mechanism has remained undetermined. Furthermore some studies have found a deficiency in the sulphuric acid budget, suggesting a missing source. In this study the production of sulphuric acid from SO2 through a number of different pathways is investigated. The production methods are standard gas phase oxidation by OH radicals produced by ozone photolysis with UV light, liquid phase oxidation by ozone, and gas phase oxidation initiated by gamma rays. The distributions of stable sulphur isotopes in the products and substrate were measured using isotope ratio mass spectrometry. All methods produced sulphate enriched in 34S and we find an enrichment factor (δ34S of 8.7 ± 0.4‰ (1 standard deviation for the UV-initiated OH reaction. Only UV light (Hg emission at 253.65 nm produced a clear non-mass-dependent excess of 33S. The pattern of isotopic enrichment produced by gamma rays is similar, but not equal, to that produced by aqueous oxidation of SO2 by ozone. This, combined with the relative yields of the experiments, suggests a mechanism in which ionising radiation may lead to hydrated ion clusters that serve as nanoreactors for S(IV to S(VI conversion.

  3. Tags and seals for arms control verification

    Energy Technology Data Exchange (ETDEWEB)

    DeVolpi, A.

    1990-09-18

    Tags and seals have long been recognized as important tools in arms control. The trend in control of armaments is to limit militarily significant equipment that is capable of being verified through direct and cooperative means, chiefly on-site inspection or monitoring. Although this paper will focus on the CFE treaty, the role of tags and seals for other treaties will also be addressed. Published technology and concepts will be reviewed, based on open sources. Arms control verification tags are defined as unique identifiers designed to be tamper-revealing; in that respect, seals are similar, being used as indicators of unauthorized access. Tamper-revealing tags might be considered as single-point markers, seals as two-point couplings, and nets as volume containment. The functions of an arms control tag can be considered to be two-fold: to provide field verification of the identity of a treaty-limited item (TLI), and to have a means of authentication of the tag and its tamper-revealing features. Authentication could take place in the field or be completed elsewhere. For CFE, the goal of tags and seals can be to reduce the overall cost of the entire verification system.

  4. Structural Design and Sealing Performance Analysis of Biomimetic Sealing Ring.

    Science.gov (United States)

    Han, Chuanjun; Zhang, Han; Zhang, Jie

    2015-01-01

    In order to reduce the failure probability of rubber sealing rings in reciprocating dynamic seal, a new structure of sealing ring based on bionics was designed. The biomimetic ring has three concave ridges and convex bulges on each side which are very similar to earthworms. Bulges were circularly designed and sealing performances of the biomimetic ring in both static seal and dynamic seal were simulated by FEM. In addition, effects of precompression, medium pressure, speed, friction coefficient, and material parameters on sealing performances were discussed. The results show that von Mises stress of the biomimetic sealing ring distributed symmetrically in no-pressure static sealing. The maximum von Mises stress appears on the second bulge of the inner side. High contact stress concentrates on left bulges. Von Mises stress distribution becomes uneven under medium pressure. Both von Mises stress and contact stress increase when precompression, medium pressure, and rubber hardness increase in static sealing. Biomimetic ring can avoid rolling and distortion in reciprocating dynamic seal, and its working life is much longer than O-ring and rectangular ring. The maximum von Mises stress and contact stress increase with the precompression, medium pressure, rubber hardness, and friction coefficient in reciprocating dynamic seal.

  5. Structural Design and Sealing Performance Analysis of Biomimetic Sealing Ring

    Directory of Open Access Journals (Sweden)

    Chuanjun Han

    2015-01-01

    Full Text Available In order to reduce the failure probability of rubber sealing rings in reciprocating dynamic seal, a new structure of sealing ring based on bionics was designed. The biomimetic ring has three concave ridges and convex bulges on each side which are very similar to earthworms. Bulges were circularly designed and sealing performances of the biomimetic ring in both static seal and dynamic seal were simulated by FEM. In addition, effects of precompression, medium pressure, speed, friction coefficient, and material parameters on sealing performances were discussed. The results show that von Mises stress of the biomimetic sealing ring distributed symmetrically in no-pressure static sealing. The maximum von Mises stress appears on the second bulge of the inner side. High contact stress concentrates on left bulges. Von Mises stress distribution becomes uneven under medium pressure. Both von Mises stress and contact stress increase when precompression, medium pressure, and rubber hardness increase in static sealing. Biomimetic ring can avoid rolling and distortion in reciprocating dynamic seal, and its working life is much longer than O-ring and rectangular ring. The maximum von Mises stress and contact stress increase with the precompression, medium pressure, rubber hardness, and friction coefficient in reciprocating dynamic seal.

  6. Structural Design and Sealing Performance Analysis of Biomimetic Sealing Ring

    Science.gov (United States)

    Han, Chuanjun

    2015-01-01

    In order to reduce the failure probability of rubber sealing rings in reciprocating dynamic seal, a new structure of sealing ring based on bionics was designed. The biomimetic ring has three concave ridges and convex bulges on each side which are very similar to earthworms. Bulges were circularly designed and sealing performances of the biomimetic ring in both static seal and dynamic seal were simulated by FEM. In addition, effects of precompression, medium pressure, speed, friction coefficient, and material parameters on sealing performances were discussed. The results show that von Mises stress of the biomimetic sealing ring distributed symmetrically in no-pressure static sealing. The maximum von Mises stress appears on the second bulge of the inner side. High contact stress concentrates on left bulges. Von Mises stress distribution becomes uneven under medium pressure. Both von Mises stress and contact stress increase when precompression, medium pressure, and rubber hardness increase in static sealing. Biomimetic ring can avoid rolling and distortion in reciprocating dynamic seal, and its working life is much longer than O-ring and rectangular ring. The maximum von Mises stress and contact stress increase with the precompression, medium pressure, rubber hardness, and friction coefficient in reciprocating dynamic seal. PMID:27019582

  7. Electromagnetic radiation from ingested sources in the human intestine between 150 MHz and 1.2 GHz.

    Science.gov (United States)

    Chirwa, Lawrence C; Hammond, Paul A; Roy, Scott; Cumming, David R S

    2003-04-01

    The conventional method of diagnosing disorders of the human gastro-intestinal (GI) tract is by sensors embedded in cannulae that are inserted through the anus, mouth, or nose. However, these cannulae cause significant patient discomfort and cannot be used in the small intestine. As a result, there is considerable ongoing work in developing wireless sensors that can be used in the small intestine. The radiation characteristics of sources in the GI tract cannot be readily calculated due to the complexity of the human body and its composite tissues, each with different electrical characteristics. In addition, the compact antennas used are electrically small, making them inefficient radiators. This paper presents radiation characteristics for sources in the GI tract that should allow for the optimum design of more efficient telemetry systems. The characteristics are determined using the finite-difference time-domain method with a realistic antenna model on an established fully segmented human body model. Radiation intensity outside the body was found to have a Gaussian-form relationship with frequency. Maximum radiation occurs between 450 and 900 MHz. The gut region was found generally to inhibit vertically polarized electric fields more than horizontally polarized fields.

  8. Static seal for turbine engine

    Science.gov (United States)

    Salazar, Santiago; Gisch, Andrew

    2014-04-01

    A seal structure for a gas turbine engine, the seal structure including first and second components located adjacent to each other and forming a barrier between high and low pressure zones. A seal cavity is defined in the first and second components, the seal cavity extending to either side of an elongated gap extending generally in a first direction between the first and second components. A seal member is positioned within the seal cavity and spans across the elongated gap. The seal member includes first and second side edges extending into each of the components in a second direction transverse to the first direction, and opposing longitudinal edges extending between the side edges generally parallel to the first direction. The side edges include a groove formed therein for effecting a reduction of gas flow around the seal member at the side edges.

  9. Study of the source term of radiation of the CDTN GE-PET trace 8 cyclotron with the MCNPX code

    Energy Technology Data Exchange (ETDEWEB)

    Benavente C, J. A.; Lacerda, M. A. S.; Fonseca, T. C. F.; Da Silva, T. A. [Centro de Desenvolvimento da Tecnologia Nuclear / CNEN, Av. Pte. Antonio Carlos 6627, 31270-901 Belo Horizonte, Minas Gerais (Brazil); Vega C, H. R., E-mail: jhonnybenavente@gmail.com [Universidad Autonoma de Zacatecas, Unidad Academica de Estudios Nucleares, Cipres No. 10, Fracc. La Penuela, 98068 Zacatecas, Zac. (Mexico)

    2015-10-15

    Full text: The knowledge of the neutron spectra in a PET cyclotron is important for the optimization of radiation protection of the workers and individuals of the public. The main objective of this work is to study the source term of radiation of the GE-PET trace 8 cyclotron of the Development Center of Nuclear Technology (CDTN/CNEN) using computer simulation by the Monte Carlo method. The MCNPX version 2.7 code was used to calculate the flux of neutrons produced from the interaction of the primary proton beam with the target body and other cyclotron components, during 18F production. The estimate of the source term and the corresponding radiation field was performed from the bombardment of a H{sub 2}{sup 18}O target with protons of 75 μA current and 16.5 MeV of energy. The values of the simulated fluxes were compared with those reported by the accelerator manufacturer (GE Health care Company). Results showed that the fluxes estimated with the MCNPX codes were about 70% lower than the reported by the manufacturer. The mean energies of the neutrons were also different of that reported by GE Health Care. It is recommended to investigate other cross sections data and the use of physical models of the code itself for a complete characterization of the source term of radiation. (Author)

  10. Chip seal design and specifications : final report.

    Science.gov (United States)

    2016-12-01

    Chip seals or seal coats, are a pavement preservation method constructed using a layer of asphalt binder that is covered by a uniformly graded aggregate. The benefits of chip seal include: sealing surface cracks, keeping water from penetrating the su...

  11. Four Sided Seal Tester

    Science.gov (United States)

    2009-07-01

    The Center for Advanced Food Technology School of Enviromental and Biological Sciences New Brunswick, NJ 08903 FTR 216 Defense Logistics Agency...specification for four sided seal tester as function of confinement plate distance” The following modifications were issued :  Jul 18, 2007 0013/01

  12. GOLD PRESSURE VESSEL SEAL

    Science.gov (United States)

    Smith, A.E.

    1963-11-26

    An improved seal between the piston and die member of a piston-cylinder type pressure vessel is presented. A layer of gold, of sufficient thickness to provide an interference fit between the piston and die member, is plated on the contacting surface of at least one of the members. (AEC)

  13. Gas path seal

    Science.gov (United States)

    Bill, R. C.; Johnson, R. D. (Inventor)

    1979-01-01

    A gas path seal suitable for use with a turbine engine or compressor is described. A shroud wearable or abradable by the abrasion of the rotor blades of the turbine or compressor shrouds the rotor bades. A compliant backing surrounds the shroud. The backing is a yieldingly deformable porous material covered with a thin ductile layer. A mounting fixture surrounds the backing.

  14. Detection of grey seal

    NARCIS (Netherlands)

    van Bleijswijk, J.; Begeman, L.; Witte, H.J.; IJsseldijk, L.L.; Brasseur, S.M.J.M.; Gröne, A.; Leopold, M.F.

    2014-01-01

    DNA was analysed from external wounds on 3 dead harbour porpoises Phocoena phocoena that were stranded in the Netherlands. Puncture wounds as well as the edges of large open wounds were sampled with sterile cotton swabs. With specific primers that target the mtDNA control region of grey seal

  15. Evaluation of shelf life of tomatoes after using radiation with cobalt-60 source

    Energy Technology Data Exchange (ETDEWEB)

    Vicalvi, Maria Claudia V.; Solidonio, Evelyne G.; Melo, Patryk; Silva, Marcio Albuquerque da; Junior, Carlos Eduardo de O.C.; Silva, Glezia Renata da; Sena, Kesia Xisto F.R. de; Colaco, Waldeciro, E-mail: claudiavicalvi@hotmail.com, E-mail: k.xisto@gmail.com, E-mail: wcolaco@ufpe.com.br [Universidade Federal de Pernanbuco (UFPE), Pernambuco, PE (Brazil)

    2013-07-01

    Tomato is one of the most consumed fruits in the world and also one of the agricultural products with most losses due to its high perishability. The objective of this research was to evaluate the increased length of shelf life of tomatoes sold in the CEASA-PE through the use of radiation in doses of 1, 1.5 and 2 kGy with Cobalt-60 source. The study used three lots of 100 tomatoes each. Of which, 25 of them were used as the control group and 75 were irradiated with one of 3 different doses. The evaluation of the shelf life of tomatoes before and after use of the radiation was made from the observation of the visual aspects of the initiation of the fruit sto decay. The samples were analyzed at of every seven days. The fruit treated as the control group of the first batch were viable with no signs of decay for more than one month wrapped in sterile plastic wrap and stored at environment temperature ± 25 deg C. It was observed that at the dose of 1.0 kGy there was a delay in the induction of shelf life over 14 days. When used a dose of 1.5 kGy there was an increase of 30 days on shelf life compared with the control group. At a dose of 2.0 kGy, the tomatoes have a shelf life of 92 days. In the second batch of fruits, the duration of tomatoes of the control group was 40 days. At a dose of 1.0 kGy was an increase of 15 days compared to control fruits. When applying the dose of 1.5 kGy, the lifetime of the fruit was 70 days and at the dose of 2.0 kGy fruits were of 106 days starting from the initial date of experiment. The third and final batch,the lifetime of the fruits were not higher than those found in previous batches, the control group had a permanence of 14 days. At the dose of 1.0 kGy, there was the additional 10 days compared to the control group. At a dose of 1.5 kGy was observed that the fruits lasted 35 days starting from the initial day of the experiment and the tomatoes that were irradiated at 2.0 kGy the duration was 45 days from the start date of the

  16. Seal for sodium sulfur battery

    Science.gov (United States)

    Topouzian, Armenag; Minck, Robert W.; Williams, William J.

    1980-01-01

    This invention is directed to a seal for a sodium sulfur battery in which the sealing is accomplished by a radial compression seal made on a ceramic component of the battery which separates an anode compartment from a cathode compartment of the battery.

  17. Is photocleavage of DNA by YOYO-1 using a synchrotron radiation light source sequence dependent?

    Science.gov (United States)

    Gilroy, Emma L; Hoffmann, Søren Vrønning; Jones, Nykola C; Rodger, Alison

    2011-10-01

    The photocleavage of double-stranded and single-stranded DNA by the fluorescent dye YOYO-1 was investigated in real time by using the synchrotron radiation light source ASTRID (ISA, Denmark) both to initiate the reaction and to monitor its progress using Couette flow linear dichroism (LD) throughout the irradiation period. The dependence of LD signals on DNA sequences and on time in the intense light beam was explored and quantified for single-stranded poly(dA), poly[(dA-dT)(2)], calf thymus DNA (ctDNA) and Micrococcus luteus DNA (mlDNA). The DNA and ligand regions of the spectrum showed different LD kinetic behaviors, and there was significant sequence dependence of the kinetics. However, in contrast to expectations from the literature, we found that poly(dA), mlDNA, low salt ctDNA and low salt poly[(dA-dT)(2)] all had significant populations of groove-bound YOYO. It seems that this mode was predominantly responsible for the catalysis of DNA cleavage. In homopolymeric DNAs, intercalated YOYO was unable to cleave DNA. In mixed-sequence DNAs the data suggest that YOYO in some but not all intercalated binding sites can cause cleavage. It is also likely that cleavage occurs at transient single-stranded regions. The reaction rates for a 100 mA beam current of 0.5-μW power varied from 0.6 h(-1) for single-stranded poly(dA) to essentially zero for low salt poly[(dG-dC)(2)] and high salt poly[(dA-dT)(2)]. At the conclusion of the experiments with each kind of DNA, uncleaved DNA with intercalated YOYO remained.

  18. RADIOLOGICAL ASSESSMENT OF SOME NATURAL SOURCES OF IONIZING RADIATION IN THE NOVGOROD REGION

    Directory of Open Access Journals (Sweden)

    A. P. Rosolovskij

    2015-01-01

    Full Text Available This article presents the assessment of some natural sources of ionizing radiation in theNovgorodregion. Among natural environment factors affecting human health in the region from radiological standpoint radon and it’s progeny are most hazardous. This is due to a very high contamination by uranium (radium of some geological formations located at the depth from several meters to several dozen meters from the earth level. Massive exploration of uranium in the region conducted on more than 30-40 blocs identified the two potentially radon-hazardous areas totaling about 25500 square kilometers: Starorusskaya and BorovitchskoLiubytinskaya. These territories contain most of the identified radioactive anomalies in the rocks, underground and ground waters. Such anomalies are typically observed at depths not exceeding 100 m.On the basis of the anomalies’, the study zoning of theNovgorodregion was conducted in accordance with the severity of potential radon hazard. Local radon-hazardous spots were pinpointed as well as their impact upon the population health. The enrichment of the rocks creates the premises for radon emission into soil air, then into the atmosphere and into dwellings. People continuously living in a house with high radon content in the air are subject to the risk of lung or upper respiratory airway cancer.The objective is to substantiate the urgency of prolongation of Radon Program.Radon, the main radiological hazard for theNovgorodregion. The study of its’ effect upon local potentially hazardous spots. Territorial radon hazard-specific zoning, determination of causality in relation to the lungand upper respiratory airway cancer.

  19. Computed tomography as a source of electron density information for radiation treatment planning

    Energy Technology Data Exchange (ETDEWEB)

    Skrzynski, Witold; Slusarczyk-Kacprzyk, Wioletta; Bulski, Wojciech [Medical Physics Dept., Center of Oncology, Warsaw (Poland); Zielinska-Dabrowska, Sylwia; Wachowicz, Marta; Kukolowicz, Pawel F. [Medical Physics Dept., Holycross Cancer Center, Kielce (Poland)

    2010-06-15

    Purpose: to evaluate the performance of computed tomography (CT) systems of various designs as a source of electron density ({rho}{sub el}) data for treatment planning of radiation therapy. Material and methods: dependence of CT numbers on relative electron density of tissue-equivalent materials (HU-{rho}{sub el} relationship) was measured for several general-purpose CT systems (single-slice, multislice, wide-bore multislice), for radiotherapy simulators with a single-slice CT and kV CBCT (cone-beam CT) options, as well as for linear accelerators with kV and MV CBCT systems. Electron density phantoms of four sizes were used. Measurement data were compared with the standard HU-{rho}{sub el} relationships predefined in two commercial treatment-planning systems (TPS). Results: the HU-{rho}{sub el} relationships obtained with all of the general-purpose CT scanners operating at voltages close to 120 kV were very similar to each other and close to those predefined in TPS. Some dependency of HU values on tube voltage was observed for bone-equivalent materials. For a given tube voltage, differences in results obtained for different phantoms were larger than those obtained for different CT scanners. For radiotherapy simulators and for kV CBCT systems, the information on {rho}{sub el} was much less precise because of poor uniformity of images. For MV CBCT, the results were significantly different than for kV systems due to the differing energy spectrum of the beam. Conclusion: the HU-{rho}{sub el} relationships predefined in TPS can be used for general-purpose CT systems operating at voltages close to 120 kV. For nontypical imaging systems (e.g., CBCT), the relationship can be significantly different and, therefore, it should always be measured and carefully analyzed before using CT data for treatment planning. (orig.)

  20. Carbonaceous aerosols and pollutants over Delhi urban environment: Temporal evolution, source apportionment and radiative forcing.

    Science.gov (United States)

    Bisht, D S; Dumka, U C; Kaskaoutis, D G; Pipal, A S; Srivastava, A K; Soni, V K; Attri, S D; Sateesh, M; Tiwari, S

    2015-07-15

    Particulate matter (PM2.5) samples were collected over Delhi, India during January to December 2012 and analysed for carbonaceous aerosols and inorganic ions (SO4(2-) and NO3(-)) in order to examine variations in atmospheric chemistry, combustion sources and influence of long-range transport. The PM2.5 samples are measured (offline) via medium volume air samplers and analysed gravimetrically for carbonaceous (organic carbon, OC; elemental carbon, EC) aerosols and inorganic ions (SO4(2-) and NO3(-)). Furthermore, continuous (online) measurements of PM2.5 (via Beta-attenuation analyser), black carbon (BC) mass concentration (via Magee scientific Aethalometer) and carbon monoxide (via CO-analyser) are carried out. PM2.5 (online) range from 18.2 to 500.6μgm(-3) (annual mean of 124.6±87.9μgm(-3)) exhibiting higher night-time (129.4μgm(-3)) than daytime (103.8μgm(-3)) concentrations. The online concentrations are 38% and 28% lower than the offline during night and day, respectively. In general, larger night-time concentrations are found for the BC, OC, NO3(-)and SO4(2-), which are seasonally dependent with larger differences during late post-monsoon and winter. The high correlation (R(2)=0.74) between OC and EC along with the OC/EC of 7.09 (day time) and 4.55 (night-time), suggest significant influence of biomass-burning emissions (burning of wood and agricultural waste) as well as secondary organic aerosol formation during daytime. Concentrated weighted trajectory (CWT) analysis reveals that the potential sources for the carbonaceous aerosols and pollutants are local emissions within the urban environment and transported smoke from agricultural burning in northwest India during post-monsoon. BC radiative forcing estimates result in very high atmospheric heating rates (~1.8-2.0Kday(-1)) due to agricultural burning effects during the 2012 post-monsoon season. Copyright © 2015 Elsevier B.V. All rights reserved.

  1. Sealed source and device design safety testing. Technical report on the findings of task 4. Investigation of a failed brachtherapy needle applicator

    Energy Technology Data Exchange (ETDEWEB)

    Lukezich, S.J.

    1997-05-01

    As a result of an incident in which a radioactive brachytherapy treatment source was temporarily unable to be retracted, an analysis was performed on the needle applicator used during the treatment. In this report, the results of laboratory evaluations of the physical, mechanical, and metallurgical condition of the subject applicator and two additional applicators are presented. A kink formed in the subject applicator during the incident. The laboratory investigation focused on identifying characteristics which would increase the susceptibility of an applicator to form a kink when subjected to bending loads. The results obtained during this investigation could not conclusively identify the cause of the kink. The subject applicator exhibited no unique features which would have made it particularly susceptible to forming a kink. The three applicators examined represent two methods of manufacturing. A number of characteristics inherent to the method used to manufacture the subject applicator which could lead to an increased susceptibility to the formation of a kink were observed. The use of an insertion device, such as the biopsy needle used during this incident, could also dramatically increase the likelihood of the formation of a kink if the applicator is subjected to bending loads. 33 figs., 4 tabs.

  2. Estimation of the radiation exposure of a chest pain protocol with ECG-gating in dual-source computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Ketelsen, Dominik; Luetkhoff, Marie H.; Thomas, Christoph; Werner, Matthias; Tsiflikas, Ilias; Reimann, Anja; Kopp, Andreas F.; Claussen, Claus D.; Heuschmid, Martin [University Hospital Tuebingen, Eberhard-Karls-University, Department of Diagnostic and Interventional Radiology, Tuebingen (Germany); Buchgeister, Markus [University Hospital, Department of Radiotherapy and Radiooncology, Tuebingen (Germany); Burgstahler, Christof [University Hospital Tuebingen, Department of Cardiology, Tuebingen (Germany)

    2009-01-15

    The aim of the study was to evaluate radiation exposure of a chest pain protocol with ECG-gated dual-source computed tomography (DSCT). An Alderson Rando phantom equipped with thermoluminescent dosimeters was used for dose measurements. Exposure was performed on a dual-source computed tomography system with a standard protocol for chest pain evaluation (120 kV, 320 mAs/rot) with different simulated heart rates (HRs). The dose of a standard chest CT examination (120 kV, 160 mAs) was also measured. Effective dose of the chest pain protocol was 19.3/21.9 mSv (male/female, HR 60), 17.9/20.4 mSv (male/female, HR 80) and 14.7/16.7 mSv (male/female, HR 100). Effective dose of a standard chest examination was 6.3 mSv (males) and 7.2 mSv (females). Radiation dose of the chest pain protocol increases significantly with a lower heart rate for both males (p = 0.040) and females (p = 0.044). The average radiation dose of a standard chest CT examination is about 36.5% that of a CT examination performed for chest pain. Using DSCT, the evaluated chest pain protocol revealed a higher radiation exposure compared with standard chest CT. Furthermore, HRs markedly influenced the dose exposure when using the ECG-gated chest pain protocol. (orig.)

  3. American College of Radiology-American Brachytherapy Society practice parameter for electronically generated low-energy radiation sources.

    Science.gov (United States)

    Devlin, Phillip M; Gaspar, Laurie E; Buzurovic, Ivan; Demanes, D Jeffrey; Kasper, Michael E; Nag, Subir; Ouhib, Zoubir; Petit, Joshua H; Rosenthal, Seth A; Small, William; Wallner, Paul E; Hartford, Alan C

    This collaborative practice parameter technical standard has been created between the American College of Radiology and American Brachytherapy Society to guide the usage of electronically generated low energy radiation sources (ELSs). It refers to the use of electronic X-ray sources with peak voltages up to 120 kVp to deliver therapeutic radiation therapy. The parameter provides a guideline for utilizing ELS, including patient selection and consent, treatment planning, and delivery processes. The parameter reviews the published clinical data with regard to ELS results in skin, breast, and other cancers. This technical standard recommends appropriate qualifications of the involved personnel. The parameter reviews the technical issues relating to equipment specifications as well as patient and personnel safety. Regarding suggestions for educational programs with regard to this parameter,it is suggested that the training level for clinicians be equivalent to that for other radiation therapies. It also suggests that ELS must be done using the same standards of quality and safety as those in place for other forms of radiation therapy. Copyright © 2017 American Brachytherapy Society and American College of Radiology. Published by Elsevier Inc. All rights reserved.

  4. The potential of global solar radiation in the Silesia region as a renewable source of energy

    Directory of Open Access Journals (Sweden)

    Waniek Katarzyna

    2016-12-01

    Full Text Available Historically, Silesia has been at the centre of the Polish coal industry for many years and thus has experienced poorer air quality compared to other voivodeships. However, in recent years strong economic transformation in the area has led to a considerable reduction in coal production. This study aimed to assess the variability of global solar radiation at selected stations within the Silesian voivodeship, in order to re-evaluate the resources of renewable solar energy during the period 1994–2013. The theoretical potential of solar radiation was calculated based on a three-dimensional terrain model. The data on global solar radiation from 13 stations within the Silesia region, covering the period 1994–2013, were obtained from the Regional Inspectorate of Environmental Protection in Katowice. The most favourable conditions for the use of solar energy were found at the cities Sosnowiec and Cieszyn. The largest increase in global radiation over the research period was observed in Zabrze. The average annual global radiation ranged between 600–1300 kWh·m−2. Digital Elevation Models (DEM for selected districts of the Silesia region were used to calculate the theoretical potential of global solar radiation. The highest theoretical potential of global radiation was found in the district of Cieszyn, located at the highest altitude.

  5. Hermetic Seal Leak Detection Apparatus

    Science.gov (United States)

    Kelley, Anthony R. (Inventor)

    2013-01-01

    The present invention is a hermetic seal leak detection apparatus, which can be used to test for hermetic seal leaks in instruments and containers. A vacuum tight chamber is created around the unit being tested to minimize gas space outside of the hermetic seal. A vacuum inducing device is then used to increase the gas chamber volume inside the device, so that a slight vacuum is pulled on the unit being tested. The pressure in the unit being tested will stabilize. If the stabilized pressure reads close to a known good seal calibration, there is not a leak in the seal. If the stabilized pressure reads closer to a known bad seal calibration value, there is a leak in the seal. The speed of the plunger can be varied and by evaluating the resulting pressure change rates and final values, the leak rate/size can be accurately calculated.

  6. Compression zone of a magnetoplasma compressor as a source of extreme UV radiation

    Science.gov (United States)

    Garkusha, I. E.; Chebotarev, V. V.; Solyakov, D. G.; Petrov, Yu. V.; Ladygina, M. S.; Marchenko, A. K.; Staltsov, V. V.; Yelisyeyev, D. V.

    2012-02-01

    Results from experimental studies of extreme UV (EUV) radiation from the compression zone of a magnetoplasma compressor (MPC) operating with xenon are presented. Two MPC operating modes that differ in the method of xenon injection into the discharge were studied. It is shown that EUV radiation in the wavelength range of 5-80 nm is emitted from the compression zone. In the MPC operating mode with local xenon injection directly into the compression zone surrounded by helium plasma, the radiation power reaches it peak value of 16-18 kW in the wavelength range of 12.2-15.8 nm.

  7. Compression zone of a magnetoplasma compressor as a source of extreme UV radiation

    Energy Technology Data Exchange (ETDEWEB)

    Garkusha, I. E.; Chebotarev, V. V.; Solyakov, D. G.; Petrov, Yu. V.; Ladygina, M. S.; Marchenko, A. K.; Staltsov, V. V.; Yelisyeyev, D. V. [National Academy of Sciences of Ukraine, Institute of Plasma Physics, National Science Center ' Kharkiv Institute of Physics and Technology,' (Ukraine)

    2012-02-15

    Results from experimental studies of extreme UV (EUV) radiation from the compression zone of a magnetoplasma compressor (MPC) operating with xenon are presented. Two MPC operating modes that differ in the method of xenon injection into the discharge were studied. It is shown that EUV radiation in the wavelength range of 5-80 nm is emitted from the compression zone. In the MPC operating mode with local xenon injection directly into the compression zone surrounded by helium plasma, the radiation power reaches it peak value of 16-18 kW in the wavelength range of 12.2-15.8 nm.

  8. Gas turbine sealing apparatus

    Science.gov (United States)

    Wiebe, David J; Wessell, Brian J; Ebert, Todd; Beeck, Alexander; Liang, George; Marussich, Walter H

    2013-02-19

    A gas turbine includes forward and aft rows of rotatable blades, a row of stationary vanes between the forward and aft rows of rotatable blades, an annular intermediate disc, and a seal housing apparatus. The forward and aft rows of rotatable blades are coupled to respective first and second portions of a disc/rotor assembly. The annular intermediate disc is coupled to the disc/rotor assembly so as to be rotatable with the disc/rotor assembly during operation of the gas turbine. The annular intermediate disc includes a forward side coupled to the first portion of the disc/rotor assembly and an aft side coupled to the second portion of the disc/rotor assembly. The seal housing apparatus is coupled to the annular intermediate disc so as to be rotatable with the annular intermediate disc and the disc/rotor assembly during operation of the gas turbine.

  9. Recovery from Iridium-192 flakes of a radioactive source for industrial use after a radiation incident; Recuperacion de hojuelas de Iridio-192 provenientes de una fuente radiactivas de uso industrial despues de un incidente radiologico

    Energy Technology Data Exchange (ETDEWEB)

    Cruz, W.H.; Zapata, L.A., E-mail: wcruz@ipen.gob.pe, E-mail: lzapata@ipen.gob.pe [Instituto Peruano de Energia Nuclear (GRRA/IPEN), Lima (Peru). Division de Gestion de Residuos Radiactivos

    2013-07-01

    The Iridium-192 ({sup 192}Ir) is the most used and ideal for industrial radiography applications, especially in petrochemical plants and pipelines and provides better contrast sensitivity for thick (25.4 mm). This source has constructive sealed double encapsulation, the internal capsule containing stainless steel to radioactive material in the form of flakes and welded with TIG process. The radiological incident happened at a gas station fuel sales in circumstances in which there was a homogeneity test welds a tank, the flakes or Ir-192 fell off his ponytail and left scattered over an area of 2 m{sup 2}, some fell flat areas and other land so collected in lead shielding and metal container and ground source. Full recovery of the leaflets was performed at the Division of radioactive waste management (GRRA) gaining a total of 22 flakes with no radiation risk to staff performance and installation and the conclusion was reached that the misapplicaion of TIG welding was the main cause the incident. (author)

  10. Assessment of the optical radiation hazard from a home-use intense pulsed light (IPL) source.

    Science.gov (United States)

    Eadie, Ewan; Miller, Paul; Goodman, Teresa; Moseley, Harry

    2009-09-01

    Intense pulsed light (IPL) systems have evolved and crossed over from the clinic to the home. Studies have shown home-use IPLs to be clinically effective but there has been no published data on ocular safety. It was our aim to measure the spectral and temporal optical radiation output from a home-use IPL and assess the ocular hazard. The iPulse Personal is a new home-use IPL hair reduction system. We measured its optical radiation spectral output using a calibrated diode array spectrometer that was traceable to national standards. Pulse duration was determined by measurement with a fast photodiode. The results from these measurements were used to assess the optical radiation hazard to the human eye. Retinal thermal hazard (RTH), blue light hazard (BLH), and infrared radiation hazard to the cornea and lens were assessed in accordance with IEC TR 60825-9 and the International Committee on Non-Ionizing Radiation Protection (ICNIRP) Guidelines on Limits of Exposure to Broad-band Incoherent Optical Radiation, as there are no specific international IPL standards. Neither the BLH radiance dose nor the infrared radiation hazard to the cornea and lens irradiance exceeded the exposure limit values (ELVs) set by the ICNIRP. The RTH radiance, however, was exceeded at a fluence of 11 J cm(-2) and pulse duration of 16 milliseconds. Following these results the settings on the IPL were adjusted and the RTH was no longer exceeded at a new fluence of 10 J cm(-2) and pulse duration of 26 milliseconds. The home-use device that we assessed does not present an optical hazard according to currently available international standards.

  11. Radiation dose efficiency of dual-energy CT benchmarked against single-source, kilovoltage-optimized scans.

    Science.gov (United States)

    Schick, Daniel; Pratap, Jit

    2016-01-01

    This study evaluated the radiation dose and image quality implications of dual-energy CT (DECT) use, compared with kilovoltage-optimized single-source/single-energy CT (SECT) on a dual-source Siemens Somatom(®) Definition Flash CT scanner (Siemens Healthcare, Forcheim, Germany). With equalized radiation dose (volumetric CT dose index), image noise (standard deviation of CT number) and signal-difference-to-noise ratio (SDNR) were measured and compared across three techniques: 100, 120 and 100/140 kVp (dual energy). Noise in a 30-cm-diameter water phantom and SDNR within unenhanced soft-tissue regions of a small adult (50 kg/165 cm) anthropomorphic phantom were utilized for the assessment. Water phantom image noise decreased with DECT compared with the lower noise SECT setting of 120 kVp (p = 0.046). A decrease in SDNR within the anthropomorphic phantom was demonstrated at 120 kVp compared with the SECT kilovoltage-optimized setting of 100 kVp (p = 0.001). A further decrease in SDNR was observed for the DECT technique when compared with 120 kVp (p = 0.01). On the Siemens Somatom Definition Flash system (Siemens Healthcare), and for equalized radiation dose conditions, image quality expressed as SDNR of unenhanced soft tissue may be compromised for DECT when compared with kilovoltage-optimized SECT, particularly for smaller patients. DECT on a dual-source CT scanner may require a radiation dose increase to maintain unenhanced soft-tissue contrast detectability, particularly for smaller patients.

  12. Estimating and correcting the amplitude radiation pattern of a virtual source

    NARCIS (Netherlands)

    Van der Neut, J.; Bakulin, A.

    2009-01-01

    In the virtual source (VS) method we crosscorrelate seismic recordings at two receivers to create a new data set as if one of these receivers were a virtual source and the other a receiver. We focus on the amplitudes and kinematics of VS data, generated by an array of active sources at the surface

  13. Thomson scattering laser-electron X-ray source for reduction of patient radiation dose in interventional coronary angiography

    Science.gov (United States)

    Artyukov, I. A.; Dyachkov, N. V.; Feshchenko, R. M.; Polunina, A. V.; Popov, N. L.; Shvedunov, V. I.; Vinogradov, A. V.

    2017-05-01

    It was medical applications that stimulated F. Carrol in the early 1990s to start the research of on relativistic Thomson scattering X-ray sources, as a part of the infrastructure of the future society. The possibility to use such a source in interventional cardiology is discussed in this paper. The replacement of X-ray tube by relativistic Thomson scattering Xray source is predicted to lower the patient radiation dose by a factor of 3 while image quality remains the same. The required general characteristics of accelerator and laser units are found. They can be reached by existing technology. A semiempirical method for simulation of medical and technical parameters of interventional coronary angiography systems is suggested.

  14. Aft outer rim seal arrangement

    Science.gov (United States)

    Lee, Ching-Pang; Tham, Kok-Mun; Schroeder, Eric; Meeroff, Jamie; Miller, Jr., Samuel R; Marra, John J; Campbell, Christian X

    2015-04-28

    An outer rim seal arrangement (10), including: an annular rim (70) centered about a longitudinal axis (30) of a rotor disc (31), extending fore and having a fore-end (72), an outward-facing surface (74), and an inward-facing surface (76); a lower angel wing (62) extending aft from a base of a turbine blade (22) and having an aft end (64) disposed radially inward of the rim inward-facing surface to define a lower angel wing seal gap (80); an upper angel wing (66) extending aft from the turbine blade base and having an aft end (68) disposed radially outward of the rim outward-facing surface to define a upper angel wing seal gap (80, 82); and guide vanes (100) disposed on the rim inward-facing surface in the lower angel wing seal gap. Pumping fins (102) may be disposed on the upper angel wing seal aft end in the upper angel wing seal gap.

  15. Development of helicopter engine seals

    Science.gov (United States)

    Lynwander, P.

    1973-01-01

    An experimental evaluation of main shaft seals for helicopter gas turbine engines was conducted with shaft speeds to 213 m/s(700 ft/sec), air pressures to 148 N/sq cm (215 psia), and air temperatures to 645 K (675 F). Gas leakage test results indicate that conventional seals will not be satisfactory for high-pressure sealing because of excessive leakage. The self-acting face seal, however, had significantly lower leakage and operated with insignificant wear during a 150-hour endurance test at sliding speeds to 145 m/s (475 ft/sec), air pressures to 124 N/sq cm (180 psia), and air temperatures to 408 K (275 F). Wear measurements indicate that noncontact operation was achieved at shaft speeds of 43,000 rpm. Evaluation of the self-acting circumferential seal was inconclusive because of seal dimensional variations.

  16. Oscillation photography of radiation-sensitive crystals using a synchrotron source

    Energy Technology Data Exchange (ETDEWEB)

    Rossmann, M.G.; Erickson, J.W. (Purdue Univ., Lafayette, IN (USA). Dept. of Biological Sciences)

    1983-12-01

    A method is described to determine the accurate setting of a crystal placed in an unknown orientation on an oscillation camera. This avoids time-consuming setting operations during which the crystal is subject to continuous radiation damage initiated by the first setting photograph. It also ensures maximal use of synchrotron radiation time as there is no need for any prior setting and developing periods. The method is dependent on measuring the lengths and orientations of the major axes of the ellipses on two, preferably approximately orthogonal, 'still' photographs. The method is applied to five different rhinovirus (common cold) crystals.

  17. Fiber Optic Safeguards Sealing System

    Science.gov (United States)

    1978-01-01

    an intergrity check of a seal than to photograph the seal’s fingerprints and to match positive/negative overlays. The seal identification time and...INSTALLATIONS, LOGISTICS fi FINANCIAL MANAGEMENT) DEPARTMENT OF THE ARMY WASHINGTON, DC 20310 ATTN OASA-IL&FM-DSM&T, E. A. ORSINI ATTK OASA-IL&FM, COL K...W, GOOCH OFFICE, DEPUTY CHIEF OF STAFF FOR LOGISTICS DEPARTMENT OF THE ARMY WASHINGTON, DC 20310 ATTN DALO-SMS, T. C. UECKERT OFFICE, DEPUTY

  18. Morphological Changes in the state of dental tissues in the treatment of deep caries with dentin-sealing liquid and low-intensity laser radiation (clinical and experimental research)

    OpenAIRE

    Kovaleva, M.; Britova, A.

    2011-01-01

    The article shows the results of morphological studies of dental hard tissues after the application of methods of treatment of deep caries with dentin-sealing liquid and low-intensity laser therapy. This new method is preventive measure against repeated and recurrent caries.

  19. Fluidtight Seal for a Container

    Energy Technology Data Exchange (ETDEWEB)

    Morrison, Edward F.

    1999-03-31

    A fluidtight seal for a container is formed by abutting a metal ring with a step machined in a convexo-concave container closure device and inserting this assembly into an open end of the container. Under compressive force, the closure device deforms causing the metal ring to pivot about the step on the closure device and interact with symmetrically tapered inner walls of the container to form a fluidtight seal between the container and the closure device. The compressive force is then withdrawn without affecting the fluidtight characteristic of the seal. A destructive force against the container closure device is necessary to destroy the fluidtight seal.

  20. MHD Boundary Layer Flow of a Nanofluid over an Exponentially Permeable Stretching Sheet with radiation and heat Source/Sink

    Directory of Open Access Journals (Sweden)

    N. Kishan

    2016-01-01

    Full Text Available The problem of steady Magnetohydrodynamic boundary layer flow of an electrically conducting nanofluid due to an exponentially permeable stretching sheet with heat source/sink in presence of thermal radiation is numerically investigated. The effect of transverse Brownian motion and thermophoresis on heat transfer and nano particle volume fraction considered. The governing partial differential equations of mass, momentum, energy and nanoparticle volume fraction equations are reduced to ordinary differential equations by using suitable similarity transformation. These equations are solved numerically using an implicit finite difference scheme, for some values of flow parameters such as Magnetic parameter (M, Wall mass transfer parameter(S, Prandtl number(Pr, Lewis number (Le, Thermophoresis parameter (Nt, Brownian motion parameter(Nb, Radiation parameter (R. The numerical values presented graphically and analized for velocity, temperature and nanoparticle volume fraction.

  1. R&D Toward a Compact High-Brilliance X-Ray Source Based on Channeling Radiation

    Energy Technology Data Exchange (ETDEWEB)

    Piot, P.; /Fermilab /Northern Illinois U.; Brau, C.A.; Choi, B.K.; Gabella, W.E.; Jarvis, J.D.; Mendenhall, M.H.; /Vanderbilt U.; Lewellen, J.W.; /Naval Postgraduate School; Mihalcea, D.; /Northern Illinois U.

    2012-08-01

    X-rays have been valuable to a large number of fields including Science, Medicine, and Security. Yet, the availability of a compact high-spectral brilliance X-ray sources is limited. A technique to produce X-rays with spectral brilliance B {approx} 10{sup 12} photons.(mm-mrd){sup -2}.(0.1% BW){sup -1} .s{sup -1} is discussed. The method is based on the generation and acceleration of a low-emittance field-emitted electron bunches. The bunches are then focused on a diamond crystal thereby producing channeling radiation. In this paper, after presenting the overarching concept, we discuss the generation, acceleration and transport of the low-emittance bunches with parameters consistent with the production of high-brilliance X-rays through channeling radiation. We especially consider the example of the Advanced Superconducting Test Accelerator (ASTA) currently in construction at Fermilab where a proof-of-principle experiment is in preparation.

  2. Fears and misperceptions of radiation therapy: sources and impact on decision-making and anxiety.

    Science.gov (United States)

    Gillan, Caitlin; Abrams, Daniel; Harnett, Nicole; Wiljer, David; Catton, Pamela

    2014-06-01

    Recent media attention about radiation has led to heightened public awareness and concern about radiation therapy (RT). An understanding of concerns and their potential role in patient decision-making can inform education efforts. A multiphase needs assessment survey was designed to ascertain broad public perceptions of radiation (phase I) and the more in-depth cancer patient perceptions of RT (phase II). One hundred forty-six phase I and 111 phase II surveys were completed. Data suggested a prevalence of negative connotations of the word "radiation," often associated with information from the media or secondhand experience. Side effects during and after RT were reported as concerns, including misperceptions about becoming radioactive and impact on fertility. Rankings of quality and safety perceptions suggested confidence in staff training and equipment, though concerns regarding overdoses and protection of healthy tissue were higher amongst those who refused RT. In deciding whether or not to undergo RT, high value was placed on the reputation of the cancer centre and the expected effectiveness of RT. The importance of understanding RT was more highly regarded by those who underwent RT than those who refused it. Perceptions of RT should thus be addressed amongst those in a position to consider RT, to maximize RT utilization where appropriate.

  3. Truss up, top out, seal off [decommissioning

    Energy Technology Data Exchange (ETDEWEB)

    Fleming, D.

    1995-09-07

    This article reports on the decommissioning of the United Kingdom`s first Magnox power station at Berkeley, in Gloucestershire. The aim of the work in progress at present is to seal off the buildings, leaving the structure maintenance free for thirty years to allow levels of radioactivity inside to fall. To reduce the visual impact of the station the top quarter of each building is also being removed. The three phases of the current scheme are described, as are the strategies in place for ensuring that construction workers are not exposed to radiation. Lessons learnt here will be applied to the decommissioning of Trawsfynydd power station. (UK).

  4. A note on the harbour seal (Phoca vitulina in the Faroe Islands

    Directory of Open Access Journals (Sweden)

    Bjarni Mikkelsen

    2010-09-01

    Full Text Available The harbour seal was exterminated as a breeding species in the Faroe Islands in the mid-19th Century. Historical sources document that the harbour seal used to be a common inhabitant of the sheltered fjords where breeding occurred. It was reported to be more common than the grey seal, the other pinniped specie resident around the Faroes. But the number of harbour seals seemingly decreased as human settlements and other anthropogenic activities increased. Seal hunting was apparently already introduced by the Norse that arrived on the islands in the 7th century, a hunt that finally lead to the extermination of the harbour seal. For the last 40 years the harbour seal has only been positively identified twice in the Faroe Islands, in 2001 and 2005.

  5. A novel-type tunable and narrowband extreme ultraviolet radiation source based on high-harmonic conversion of picosecond laser pulses

    NARCIS (Netherlands)

    Barkauskas, M.; Brandi, F.; Giammanco, F.; Neshev, D.; Pirri, A.; Ubachs, W.M.G.

    2005-01-01

    At the Laser Centre Vrije Universiteit a table-top size, tunable and narrowband laser-based source of extreme ultraviolet radiation was developed using high-harmonic generation of powerful laser pulses of 300 ps duration and Fourier-transform limited bandwidth. The generated radiation has

  6. DEFINITION OF DIRECTION ON SOURCE OF ACOUSTIC RADIATION WITH USE OF ARRANGEMENTS OF REGISTRAITION OF RESILIENT WAVES ON OPTICS, VICROWAVE AND ULTRASONIC BEAMS

    Directory of Open Access Journals (Sweden)

    S. A. Dubyanskiy

    2014-01-01

    Full Text Available The article considers the principles of defining the direction to the acoustic radiation source. The results of the research in the field of directing properties of the registrating devices when operating these beams are cited.

  7. RCT: Module 2.08, Radiological Source Control, Course 8774

    Energy Technology Data Exchange (ETDEWEB)

    Hillmer, Kurt T. [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2017-08-10

    radioactive source is material used for its emitted radiation. Sources are sealed or unsealed and are classified as accountable or exempt. Radioactive sources are used for response checks, functional checks, and the calibration of instruments and monitors to traceable standards. To ensure the safety and welfare of all personnel, it is important to maintain control of radioactive sources to minimize the potential for the spread of contamination, unnecessary exposure to personnel, loss or theft, and improper disposal. This course will prepare the student with the skills necessary for RCT qualification by passing quizzes, tests, and the RCT Comprehensive Phase 1, Unit 2 Examination (TEST 27566) and will provide in-the-field skills.

  8. Analysis of the numerical results of the melting paraffin corks, ensuring the safe operation of the pipeline using a mobile source of electromagnetic radiation

    Directory of Open Access Journals (Sweden)

    Titarenko Vera

    2017-01-01

    Full Text Available For the safe operation of the pipeline, ensuring its smooth operation was conducted analysis of the results of numerical simulation of melting of paraffin jams with using a mobile source of electromagnetic radiation. Carried out varying different parameters of the radiation source, the peculiarities of its movement, the nature of the change of geometry of the boundary of melting of paraffin plugs under different external conditions

  9. On the radiation safety studies of space nuclear sources at the Scientific-Research Institute of Thermal Processes

    Energy Technology Data Exchange (ETDEWEB)

    Koroteev, A.S.; Gafarov, A.A.; Bakhtin, B.I.; Kosov, A.V. (The Scientific-Research Institute of Thermal Processes, 8, Onezhskaya, Moscow, 125438 (SU))

    1991-01-01

    The main directions and some results of the theoretical and experimental studies, carried out at the Scientific-Research Institute of Thermal Processes on the radiation safety (RS) problem of the space nuclear power sources (SNPS), are stated. The experimental base for SNPS aerodynamic heating and breakup research is described. Some results of studies on the development of RS system for SNPS of Cosmos-954''-type satellites and SNPS Topaz'' are represented. The main directions and results of research on the RS problem of radioisotope SNPS is showen. Some aspects of SNPS possible collisions with space debris in near-earth orbits is examined.

  10. Dense plasma focus PACO as a hard X-ray emitter: a study on the radiation source

    OpenAIRE

    Supán, L.; Guichón, S.; Milanese, Maria Magdalena; Niedbalski, Jorge Julio; Moroso, Roberto Luis; Acuña, H.; Malamud, Florencia

    2016-01-01

    The radiation in the X-ray range detected outside the vacuum chamber of the dense plasma focus (DPF) PACO, are produced on the anode zone. The zone of emission is studied in a shot-to-shot analysis, using pure deuterium as filling gas. We present a diagnostic method to determine the place and size of the hard X-ray source by image analysis of high density radiography plates. Fil: Supán, L.. Universidad Nacional del Centro de la Provincia de Buenos Aires. Facultad de Ciencias Exactas. Insti...

  11. Complex Source and Radiation Behaviors of Small Elements of Linear and Matrix Flexible Ultrasonic Phased-Array Transducers

    Science.gov (United States)

    Amory, V.; Lhémery, A.

    2008-02-01

    Inspection of irregular components is problematical: maladjustment of transducer shoes to surfaces causes aberrations. Flexible phased-arrays (FPAs) designed at CEA LIST to maximize contact are driven by adapted delay laws to compensate for irregularities. Optimizing FPA requires simulation tools. The behavior of one element computed by FEM is observed at the surface and its radiation experimentally validated. Efforts for one element prevent from simulating a FPA by FEM. A model is proposed where each element behaves as nonuniform source of stresses. Exact and asymptotic formulas for Lamb problem are used as convolution kernels for longitudinal, transverse and head waves; the latter is of primary importance for angle-T-beam inspections.

  12. Terahertz radiation source using a high-power industrial electron linear accelerator

    Science.gov (United States)

    Kalkal, Yashvir; Kumar, Vinit

    2017-04-01

    High-power (˜ 100 kW) industrial electron linear accelerators (linacs) are used for irradiations, e.g., for pasteurization of food products, disinfection of medical waste, etc. We propose that high-power electron beam from such an industrial linac can first pass through an undulator to generate useful terahertz (THz) radiation, and the spent electron beam coming out of the undulator can still be used for the intended industrial applications. This will enhance the utilization of a high-power industrial linac. We have performed calculation of spontaneous emission in the undulator to show that for typical parameters, continuous terahertz radiation having power of the order of μW can be produced, which may be useful for many scientific applications such as multispectral imaging of biological samples, chemical samples etc.

  13. Studies of Collisional and Nonlinear Radiative Processes for Development of Coherent UV and XUV Sources

    Science.gov (United States)

    1991-06-04

    Production of Vacuum Ultraviolet Radiation in the Rare Gases," J. Opt. Soc. Am. B 4, 595 (1987). 76. R. Rosman . G. Gibson, K. Boyer, H. Jara, T. S. Luk...R. Rosman , T. S. Luk, I. A. McIntyre, A. McPherson, G. Wendin, K. Boyer, and C. K. Rhodes, "Characteristics of a Non-Equilibrium Picosecond Laser...A. C. Wahl, "Molecular Orbital Densities: Pictorial Studies, Comparisons of the Hydrogen, Lithium , Boron, Carbon, Nitrogen, Oxygen, and Fluorine

  14. Radiation protection for an intraoperative X-ray source compared to C-arm fluoroscopy.

    Science.gov (United States)

    Schneider, Frank; Clausen, Sven; Jahnke, Anika; Steil, Volker; Bludau, Frederic; Sütterlin, Marc; Obertacke, Udo; Wenz, Frederik

    2014-09-01

    Intraoperative radiotherapy (IORT) using the INTRABEAM(®) system promises a flexible use regarding radiation protection compared to other approaches such as electron treatment or HDR brachytherapy with (192)Ir or (60)Co. In this study we compared dose rate measurements of breast- and Kypho-IORT with C-arm fluoroscopy which is needed to estimate radiation protection areas. C-arm fluoroscopy, breast- and Kypho-IORTs were performed using phantoms (silicon breast or bucket of water). Dose rates were measured at the phantom's surface, at 30 cm, 100 cm and 200 cm distance. Those measurements were confirmed during 10 Kypho-IORT and 10 breast-IORT patient treatments. The measured dose rates were in the same magnitude for all three paradigms and ranges from 20 μSv/h during a simulated breast-IORT at two meter distance up to 64 mSv/h directly at the surface of a simulated Kypho-IORT. Those measurements result in a circle of controlled area (yearly doses >6 mSv) for each paradigm of about 4 m±2 m. All three paradigms show comparable dose rates which implies that the radiation protection is straight forward and confirms the flexible use of the INTRABEAM(®) system. Copyright © 2013. Published by Elsevier GmbH.

  15. Radiation protection for an intraoperative X-ray source compared to C-arm fluoroscopy

    Energy Technology Data Exchange (ETDEWEB)

    Schneider, Frank; Clausen, Sven; Jahnke, Anika; Steil, Volker; Wenz, Frederik [Heidelberg Univ., University Medical Center Mannheim (Germany). Dept. of Radiation Oncology; Bludau, Frederic; Obertacke, Udo [Heidelberg Univ., University Medical Center Mannheim (Germany). Dept. of Trauma Surgery; Suetterlin, Marc [Heidelberg Univ., University Medical Center Mannheim (Germany). Dept. of Obstetrics and Gynaecology

    2014-10-01

    Background: Intraoperative radiotherapy (IORT) using the INTRABEAM {sup registered} system promises a flexible use regarding radiation protection compared to other approaches such as electron treatment or HDR brachytherapy with {sup 192}Ir or {sup 60}Co. In this study we compared dose rate measurements of breast- and Kypho-IORT with C-arm fluoroscopy which is needed to estimate radiation protection areas. Materials and Methods: C-arm fluoroscopy, breast- and Kypho-IORTs were performed using phantoms (silicon breast or bucket of water). Dose rates were measured at the phantom's surface, at 30 cm, 100 cm and 200 cm distance. Those measurements were confirmed during 10 Kypho-IORT and 10 breast-IORT patient treatments. Results: The measured dose rates were in the same magnitude for all three paradigms and ranges from 20 μSv/h during a simulated breast-IORT at two meter distance up to 64 mSv/h directly at the surface of a simulated Kypho-IORT. Those measurements result in a circle of controlled area (yearly doses > 6 mSv) for each paradigm of about 4 m ± 2 m. Discussion/Conclusions: All three paradigms show comparable dose rates which implies that the radiation protection is straight forward and confirms the flexible use of the INTRABEAM {sup registered} system. (orig.)

  16. Seal between metal and ceramic conduits

    Energy Technology Data Exchange (ETDEWEB)

    Underwood, Richard Paul; Tentarelli, Stephen Clyde

    2015-02-03

    A seal between a ceramic conduit and a metal conduit of an ion transport membrane device consisting of a sealing surface of ceramic conduit, a sealing surface of ceramic conduit, a single gasket body, and a single compliant interlayer.

  17. leonina and Cape fur seals Arctocephalus pusillus

    African Journals Online (AJOL)

    Namibia, was observed catching, killing and attempting copulation with female fur seals Arc- tocephalus pusillus, as well as catching and occasionally kill- ing fur seal pups and participating in territorial disputes with fur seal bulls. Previous and ...

  18. Toward an Improved Hypersonic Engine Seal

    Science.gov (United States)

    Dunlap, Patrick H., Jr.; Steinetz, Bruce M.; DeMange,Jeffrey J.; Taylor, Shawn C.

    2003-01-01

    High temperature, dynamic seals are required in advanced engines to seal the perimeters of movable engine ramps for efficient, safe operation in high heat flux environments at temperatures from 2000 to 2500 F. Current seal designs do not meet the demanding requirements for future engines, so NASA s Glenn Research Center (GRC) is developing advanced seals to overcome these shortfalls. Two seal designs and two types of seal preloading devices were evaluated in a series of compression tests at room temperature and 2000 F and flow tests at room temperature. Both seals lost resiliency with repeated load cycling at room temperature and 2000 F, but seals with braided cores were significantly more flexible than those with cores composed of uniaxial ceramic fibers. Flow rates for the seals with cores of uniaxial fibers were lower than those for the seals with braided cores. Canted coil springs and silicon nitride compression springs showed promise conceptually as potential seal preloading devices to help maintain seal resiliency.

  19. Face-Sealing Butterfly Valve

    Science.gov (United States)

    Tervo, John N.

    1992-01-01

    Valve plate made to translate as well as rotate. Valve opened and closed by turning shaft and lever. Interactions among lever, spring, valve plate, and face seal cause plate to undergo combination of translation and rotation so valve plate clears seal during parts of opening and closing motions.

  20. High temperature autoclave vacuum seals

    Science.gov (United States)

    Hoffman, J. R.; Simpson, W. G.; Walker, H. M.

    1971-01-01

    Aluminum sheet forms effective sealing film at temperatures up to 728 K. Soft aluminum wire rings provide positive seal between foil and platen. For applications at temperatures above aluminum's service temperature, stainless steel is used as film material and copper wire as sealant.

  1. Conical O-ring seal

    Science.gov (United States)

    Chalfant, Jr., Gordon G.

    1984-01-01

    A shipping container for radioactive or other hazardous materials which has a conical-shaped closure containing grooves in the conical surface thereof and an O-ring seal incorporated in each of such grooves. The closure and seal provide a much stronger, tighter and compact containment than with a conventional flanged joint.

  2. Polaradiometric pyrometer in which the parallel and perpendicular components of radiation reflected from an unpolarized light source are equalized with the thermal radiation emitted from a measured object to determine its true temperature

    Science.gov (United States)

    Abtahi, Ali A. (Inventor)

    1995-01-01

    A radiation pyrometer for measuring the true temperature of a body is provided by detecting and measuring thermal radiation from the body based on the principle that the effects of angular emission I(sub 1) and reflection I(sub 2) on the polarization states p and s of radiation are complementary such that upon detecting the combined partial polarization state components I(sub p) =I(sub 1p) + I(sub 2p) and I(sub s)=I(sub 1s) + I(sub 2s) and adjusting the intensity of the variable radiation source of the reflected radiation I(sub 2) until the combined partial radiation components I(sub p) and I(sub s) are equal, the effects of emissivity as well as diffusivity of the surface of the body are eliminated, thus obviating the need for any post processing of brightness temperature data.

  3. PRELIMINARY REPORT: EFFECTS OF IRRADIATION AND THERMAL EXPOSURE ON ELASTOMERIC SEALS FOR CASK TRANSPORTATION AND STORAGE

    Energy Technology Data Exchange (ETDEWEB)

    Verst, C.; Skidmore, E.; Daugherty, W.

    2014-05-30

    A testing and analysis approach to predict the sealing behavior of elastomeric seal materials in dry storage casks and evaluate their ability to maintain a seal under thermal and radiation exposure conditions of extended storage and beyond was developed, and initial tests have been conducted. The initial tests evaluate the aging response of EPDM elastomer O-ring seals. The thermal and radiation exposure conditions of the CASTOR® V/21 casks were selected for testing as this cask design is of interest due to its widespread use, and close proximity of the seals to the fuel compared to other cask designs leading to a relatively high temperature and dose under storage conditions. A novel test fixture was developed to enable compression stress relaxation measurements for the seal material at the thermal and radiation exposure conditions. A loss of compression stress of 90% is suggested as the threshold at which sealing ability of an elastomeric seal would be lost. Previous studies have shown this value to be conservative to actual leakage failure for most aging conditions. These initial results indicate that the seal would be expected to retain sealing ability throughout extended storage at the cask design conditions, though longer exposure times are needed to validate this assumption. The high constant dose rate used in the testing is not prototypic of the decreasingly low dose rate that would occur under extended storage. The primary degradation mechanism of oxidation of polymeric compounds is highly dependent on temperature and time of exposure, and with radiation expected to exacerbate the oxidation.

  4. Airfoil seal system for gas turbine engine

    Science.gov (United States)

    None, None

    2013-06-25

    A turbine airfoil seal system of a turbine engine having a seal base with a plurality of seal strips extending therefrom for sealing gaps between rotational airfoils and adjacent stationary components. The seal strips may overlap each other and may be generally aligned with each other. The seal strips may flex during operation to further reduce the gap between the rotational airfoils and adjacent stationary components.

  5. 'Moving source': feasibility of diffraction experiment with nanosecond time resolution by the fast synchrotron radiation beam scanning

    CERN Document Server

    Tolochko, B P; Mezentsev, N A; Mishnev, S I

    2000-01-01

    We propose combination of electronical and X-ray optical scheme that will allow one to fulfil the diffraction experiment with a nanosecond time resolution. In this scheme, a few bunches of electrons will be in the nearest separatrixes. They will move inside the undulator along the different trajectories and at different moments t sub i. Each trajectory will have a different deviation above the stationary orbit. As a result there will be a shift of the synchrotron radiation (SR) generation point from the equilibrium position. So, a discretely moving source of SR will be created: the SR will be radiated at t sub i moment and from the ith point. For each ith trajectory of electrons (and for SR), a single-coordinate detector D sub i will be placed for diffracted radiation collecting from the ith point of the sample. So, every new X-ray diffraction image will be received within time interval t sub i sub - sub 1 -t sub i which is equal to a few nanoseconds. The exposure time may be as short as the electron bunch du...

  6. A comparison of absolute calibrations of a radiation thermometer based on a monochromator and a tunable source

    Energy Technology Data Exchange (ETDEWEB)

    Keawprasert, T. [National Institute of Metrology Thailand, Pathum thani (Thailand); Anhalt, K.; Taubert, D. R.; Sperling, A.; Schuster, M.; Nevas, S. [Physikalisch Technische Bundesanstalt, Braunschweig and Berlin (Germany)

    2013-09-11

    An LP3 radiation thermometer was absolutely calibrated at a newly developed monochromator-based set-up and the TUneable Lasers in Photometry (TULIP) facility of PTB in the wavelength range from 400 nm to 1100 nm. At both facilities, the spectral radiation of the respective sources irradiates an integrating sphere, thus generating uniform radiance across its precision aperture. The spectral irradiance of the integrating sphere is determined via an effective area of a precision aperture and a Si trap detector, traceable to the primary cryogenic radiometer of PTB. Due to the limited output power from the monochromator, the absolute calibration was performed with the measurement uncertainty of 0.17 % (k= 1), while the respective uncertainty at the TULIP facility is 0.14 %. Calibration results obtained by the two facilities were compared in terms of spectral radiance responsivity, effective wavelength and integral responsivity. It was found that the measurement results in integral responsivity at the both facilities are in agreement within the expanded uncertainty (k= 2). To verify the calibration accuracy, the absolutely calibrated radiation thermometer was used to measure the thermodynamic freezing temperatures of the PTB gold fixed-point blackbody.

  7. Repetitively pulsed UV radiation source based on a run-away electron preionised diffuse discharge in nitrogen

    Energy Technology Data Exchange (ETDEWEB)

    Baksht, E Kh; Burachenko, A G; Lomaev, M I; Panchenko, A N; Tarasenko, V F [Institute of High Current Electronics, Siberian Branch, Russian Academy of Sciences, Tomsk (Russian Federation)

    2015-04-30

    An extended repetitively pulsed source of spontaneous UV radiation is fabricated, which may also be used for producing laser radiation. Voltage pulses with an incident wave amplitude of up to 30 kV, a half-amplitude duration of ∼4 ns and a rise time of ∼2.5 ns are applied to a gap with a nonuniform electric field. For an excitation region length of 35 cm and a nitrogen pressure of 30 – 760 Torr, a diffusive discharge up to a pulse repetition rate of 2 kHz is produced without using an additional system for gap preionisation. An investigation is made of the plasma of the run-away electron preionised diffuse discharge. Using a CCD camera it is found that the dense diffused plasma fills the gap in a time shorter than 1 ns. X-ray radiation is recorded from behind the foil anode throughout the pressure range under study; a supershort avalanche electron beam is recorded by the collector electrode at pressures below 100 Torr. (laser applications and other topics in quantum electronics)

  8. Repetitively pulsed UV radiation source based on a run-away electron preionised diffuse discharge in nitrogen

    Science.gov (United States)

    Baksht, E. Kh; Burachenko, A. G.; Lomaev, M. I.; Panchenko, A. N.; Tarasenko, V. F.

    2015-04-01

    An extended repetitively pulsed source of spontaneous UV radiation is fabricated, which may also be used for producing laser radiation. Voltage pulses with an incident wave amplitude of up to 30 kV, a half-amplitude duration of ~4 ns and a rise time of ~2.5 ns are applied to a gap with a nonuniform electric field. For an excitation region length of 35 cm and a nitrogen pressure of 30 - 760 Torr, a diffusive discharge up to a pulse repetition rate of 2 kHz is produced without using an additional system for gap preionisation. An investigation is made of the plasma of the run-away electron preionised diffuse discharge. Using a CCD camera it is found that the dense diffused plasma fills the gap in a time shorter than 1 ns. X-ray radiation is recorded from behind the foil anode throughout the pressure range under study; a supershort avalanche electron beam is recorded by the collector electrode at pressures below 100 Torr.

  9. Limit of detection of a fiber optics gyroscope using a super luminescent radiation source

    CERN Document Server

    Sandoval, G E

    2003-01-01

    The main objective of this work is to establish the dependence of characteristics of the fiber optics gyroscope (FOG) with respect to the parameters of the super luminescent emission source based on doped optical fiber with rare earth elements (Super luminescent Fiber Source, SFS), argument the pumping rate election of the SFS to obtain characteristics limits of the FOG sensibility. By using this type of emission source in the FOG is recommend to use the rate when the direction of the pumping signal coincide with the super luminescent signal. The most results are the proposition and argumentation of the SFS election as emission source to be use in the FOG of the phase type. Such a decision allow to increase the characteristics of the FOG sensibility in comparison with the use of luminescent source of semiconductors emission which are extensively used in the present time. The use of emission source of the SFS type allow to come closer to the threshold of the obtained sensibility limit (detection limit) which i...

  10. Aerodynamic seals for rotary machine

    Science.gov (United States)

    Bidkar, Rahul Anil; Cirri, Massimiliano; Thatte, Azam Mihir; Williams, John Robert

    2016-02-09

    An aerodynamic seal assembly for a rotary machine includes multiple sealing device segments disposed circumferentially intermediate to a stationary housing and a rotor. Each of the segments includes a shoe plate with a forward-shoe section and an aft-shoe section having multiple labyrinth teeth therebetween facing the rotor. The sealing device segment also includes multiple flexures connected to the shoe plate and to a top interface element, wherein the multiple flexures are configured to allow the high pressure fluid to occupy a forward cavity and the low pressure fluid to occupy an aft cavity. Further, the sealing device segments include a secondary seal attached to the top interface element at one first end and positioned about the flexures and the shoe plate at one second end.

  11. Preliminary dosimetric characterisation of thermoluminescent materials for beta radiation monitoring at nuclear medicine services.

    Science.gov (United States)

    Cecatti, Sonia G P; Caldas, Linda V E

    2006-01-01

    Beta emitters are widely used in nuclear medicine for diagnostic and therapeutic purposes. The critical groups exposed to a radioactive patient include the staff, other patients and members of the public accompanying the patient. The aim of this work is to characterise thermoluminescent (TL) materials for the staff monitoring of nuclear medicine services that manipulate beta radiation solutions of (153)Sm. This study was performed using CaSO(4):Dy + Teflon pellets, produced at IPEN, with different dimensions. For the dosimetric characterisation, these TL dosemeters were exposed to gamma source ((60)Co) and to beta sealed sources ((90)Sr + (90)Y, (204)Tl and (147)Pm) and to a non-sealed source ((153)Sm). Results were obtained related to reproducibility, lower detection limits, calibration curves, angle and energy dependence of response. All tested materials show usefulness for monitoring of workers exposed to beta radiation.

  12. Turbine and Structural Seals Team Facilities

    Data.gov (United States)

    Federal Laboratory Consortium — Seals Team Facilities conceive, develop, and test advanced turbine seal concepts to increase efficiency and durability of turbine engines. Current projects include...

  13. Technological yields of sources for radiation processing; Wydajnosci technologiczne zrodel do obrobki radiacyjnej

    Energy Technology Data Exchange (ETDEWEB)

    Zagorski, Z.P. [Institute of Nuclear Chemistry and Technology, Warsaw (Poland)

    1993-12-31

    The present report is prepared for planners of radiation processing of any material. Calculations are focused on accelerators of electrons, divided into two groups: versatile linacs of energy up to 13 MeV, and accelerators of lower energy, below 2 MeV, of better energy yield but of limited applications. The calculations are connected with the confrontation of the author`s technological expectations during the preparation of the linac project in the late `60s, with the results of 25 years of exploitation of the machine. One has to realize that from the 200 kW input power from the mains, only 5 kW of bent and scanned beam is recovered on the conveyor. That power is only partially used for radiation induced phenomena, because of the demanded homogeneity of the dose, of the mode of packing of the object and its shape, of edges of the scanned area and in the spaces between boxes, and of loses during the idle time due to the tuning of the machine and dosimetric operations. The use of lower energy accelerators may be more economical than that of linacs in case of objects of specific type. At the first stage already, that is of the conversion of electrical power into that of low energy electron beam, the yield is 2-3 times better than in the case of linacs. Attention has been paid to the technological aspects of electron beam conversion into the more penetrating Bremsstrahlung similar to gamma radiation. The advantages of technologies, which make possible a control of the shape of the processed object are stressed. Special attention is focused to the relation between the yield of processing and the ratio between the maximum to the minimum dose in the object under the irradiation. (author). 14 refs, 14 figs.

  14. Standard Practice for Minimizing Dosimetry Errors in Radiation Hardness Testing of Silicon Electronic Devices Using Co-60 Sources

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2010-01-01

    1.1 This practice covers recommended procedures for the use of dosimeters, such as thermoluminescent dosimeters (TLD's), to determine the absorbed dose in a region of interest within an electronic device irradiated using a Co-60 source. Co-60 sources are commonly used for the absorbed dose testing of silicon electronic devices. Note 1—This absorbed-dose testing is sometimes called “total dose testing” to distinguish it from “dose rate testing.” Note 2—The effects of ionizing radiation on some types of electronic devices may depend on both the absorbed dose and the absorbed dose rate; that is, the effects may be different if the device is irradiated to the same absorbed-dose level at different absorbed-dose rates. Absorbed-dose rate effects are not covered in this practice but should be considered in radiation hardness testing. 1.2 The principal potential error for the measurement of absorbed dose in electronic devices arises from non-equilibrium energy deposition effects in the vicinity o...

  15. Controlled/living radical polymerization of methyl methacrylate using γ-radiation as an initiation source

    Science.gov (United States)

    Zhou, Ying; Zhu, Jian; Zhu, Xiulin; Cheng, Zhenping

    2006-04-01

    A controlled/living radical polymerization, initiated by γ-radiation and followed by a post-polymerization process, of methyl methacrylate (MMA) was carried out in the presence of 2-cyanoprop-2-yl 1-dithionaphthalate. The polymerization showed first-order kinetics. The molecular weights of the corresponding polymers increased linearly with conversion. The molecular weight distributions ( M/M) of the polymers decreased with the conversion (minimal M/M value: 1.09). The polymers were characterized by 1H NMR and gel-permeation chromatograph. Chain-extension reaction was also successfully carried out to obtain higher molecular weight PMMA with narrow molecular weight distribution.

  16. The role of Cobalt-60 source in Intensity Modulated Radiation Therapy: From modeling finite sources to treatment planning and conformal dose delivery

    Science.gov (United States)

    Dhanesar, Sandeep Kaur

    Cobalt-60 (Co-60) units played an integral role in radiation therapy from the mid-1950s to the 1970s. Although they continue to be used to treat cancer in some parts of the world, their role has been significantly reduced due to the invention of medical linear accelerators. A number of groups have indicated a strong potential for Co-60 units in modern radiation therapy. The Medical Physics group at the Cancer Center of the Southeastern Ontario and Queen's University has shown the feasibility of Intensity Modulated Radiation Therapy (IMRT) via simple conformal treatment planning and dose delivery using a Co-60 unit. In this thesis, initial Co-60 tomotherapy planning investigations on simple uniform phantoms are extended to actual clinical cases based on patient CT data. The planning is based on radiation dose data from a clinical Co-60 unit fitted with a multileaf collimator (MLC) and modeled in the EGSnrc Monte Carlo system. An in house treatment planning program is used to calculate IMRT dose distributions. Conformal delivery in a single slice on a uniform phantom based on sequentially delivered pencil beams is verified by Gafchromic film. Volumetric dose distributions for Co-60 serial tomotherapy are then generated for typical clinical sites that had been treated at our clinic by conventional 6MV IMRT using Varian Eclipse treatment plans. The Co-60 treatment plans are compared with the clinical IMRT plans using conventional matrices such as dose volume histograms (DVH). Dose delivery based on simultaneously opened MLC leaves is also explored and a novel MLC segmentation method is proposed. In order to increase efficiency of dose calculations, a novel convolution based fluence model for treatment planning is also proposed. The ion chamber measurements showed that the Monte Carlo modeling of the beam data under the MIMiC MLC is accurate. The film measurements from the uniform phantom irradiations confirm that IMRT plans from our in-house treatment planning system

  17. Performance analysis of Wald-statistic based network detection methods for radiation sources

    Energy Technology Data Exchange (ETDEWEB)

    Sen, Satyabrata [ORNL; Rao, Nageswara S [ORNL; Wu, Qishi [University of Memphis; Barry, M. L.. [New Jersey Institute of Technology; Grieme, M. [New Jersey Institute of Technology; Brooks, Richard R [ORNL; Cordone, G. [Clemson University

    2016-01-01

    There have been increasingly large deployments of radiation detection networks that require computationally fast algorithms to produce prompt results over ad-hoc sub-networks of mobile devices, such as smart-phones. These algorithms are in sharp contrast to complex network algorithms that necessitate all measurements to be sent to powerful central servers. In this work, at individual sensors, we employ Wald-statistic based detection algorithms which are computationally very fast, and are implemented as one of three Z-tests and four chi-square tests. At fusion center, we apply the K-out-of-N fusion to combine the sensors hard decisions. We characterize the performance of detection methods by deriving analytical expressions for the distributions of underlying test statistics, and by analyzing the fusion performances in terms of K, N, and the false-alarm rates of individual detectors. We experimentally validate our methods using measurements from indoor and outdoor characterization tests of the Intelligence Radiation Sensors Systems (IRSS) program. In particular, utilizing the outdoor measurements, we construct two important real-life scenarios, boundary surveillance and portal monitoring, and present the results of our algorithms.

  18. Rim seal arrangement having pumping feature

    Science.gov (United States)

    Lee, Ching-Pang; Myers, Caleb

    2017-04-25

    A rim seal arrangement for a gas turbine engine includes a first seal face on a rotor component, and a second seal face on a stationary annular rim centered about a rotation axis of the rotor component. The second seal face is spaced from the first seal face along an axial direction to define a seal gap. The seal gap is located between a radially outer hot gas path and a radially inner rotor cavity. The first seal face has a plurality of circumferentially spaced depressions, each having a depth in an axial direction and extending along a radial extent of the first seal face. The depressions influence flow in the seal gap such that during rotation of the rotor component, fluid in the seal gap is pumped in a radially outward direction to prevent ingestion of a gas path fluid from the hot gas path into the rotor cavity.

  19. Directional radiation detectors

    Energy Technology Data Exchange (ETDEWEB)

    Dowell, Jonathan L.

    2017-09-12

    Directional radiation detectors and systems, methods, and computer-readable media for using directional radiation detectors to locate a radiation source are provided herein. A directional radiation detector includes a radiation sensor. A radiation attenuator partially surrounds the radiation sensor and defines an aperture through which incident radiation is received by the radiation sensor. The aperture is positioned such that when incident radiation is received directly through the aperture and by the radiation sensor, a source of the incident radiation is located within a solid angle defined by the aperture. The radiation sensor senses at least one of alpha particles, beta particles, gamma particles, or neutrons.

  20. Optoelectronic sensors of gazes on the base of multi-element sources of IR-radiation

    Directory of Open Access Journals (Sweden)

    Kabatsiy V. N.

    2010-06-01

    Full Text Available The constructions of optoelectronic sensors to methane and carbon dioxide, taking into account the peculiarities of spectral characteristics of sources and receivers of medium IR-diapason spectrum are proposed. The possibility of use of optoelectronic sensors for the measuring of CH4 and CO2 concentration in diapason 0—3 vol.% is demonstrated.

  1. A high-performance doped photocatalysts for inactivation of total coliforms in superficial waters using different sources of radiation.

    Science.gov (United States)

    Claro, Elis Marina Turini; Bidoia, Ederio Dino; de Moraes, Peterson Bueno

    2016-07-15

    Photocatalytic water treatment has a currently elevated electricity demand and maintenance costs, but the photocatalytic water treatment may also assist in overcoming the limitations and drawbacks of conventional water treatment processes. Among the Advanced Oxidation Processes, heterogeneous photocatalysis is one of the most widely and efficiently used processes to degrade and/or remove a wide range of polluting compounds. The goal of this work was to find out a highly efficient photocatalytic disinfection process in superficial water with different doped photocatalysts and using three sources of radiation: mercury vapor lamp, solar simulator and UV-A LED. Three doped photocatalysts were prepared, SiZnO, NSiZnO and FNSiZnO. The inactivation efficiency of each synthesized photocatalysts was compared to a TiO2 P25 (Degussa(®)) 0.5 g L(-1) control. Photolysis inactivation efficiency was 85% with UV-A LED, which is considered very high, demanding low electricity consumption in the process, whereas mercury vapor lamp and solar simulator yielded 19% and 13% inactivation efficiency, respectively. The best conditions were found with photocatalysts SiZnO, FNSiZnO and NSiZnO irradiated with UV-A LED, where efficiency exceeded 95% that matched inactivation of coliforms using the same irradiation and photocatalyst TiO2. All photocatalysts showed photocatalytic activity with all three radiation sources able to inactivate total coliforms from river water. The use of UV-A LED as the light source without photocatalyst is very promising, allowing the creation of cost-effective and highly efficient water treatment plants. Copyright © 2016 Elsevier Ltd. All rights reserved.

  2. A model to predict modal radiation by finite-sized sources in semi-infinite isotropic plates

    Science.gov (United States)

    Stévenin, M.; Lhémery, A.; Grondel, S.

    2017-01-01

    Elastic guided wave (GW) propagation is involved in various non-destructive testing (NDT) techniques of plate-like structures. The present paper aims at describing an efficient model to predict the GW field radiated by various sources attached at a distance of the straight boundary of an isotropic plate, a configuration often encountered in typical examinations. Since the interpretation of GW propagation and scattering in plates is made easier by the use of modal description, the model is derived in the classical theoretical framework of modal solutions. Direct radiation by a uniform source of finite size in an isotropic plate can be efficiently modelled by deriving Fraunhofer-like approximation. A rigorous treatment is proposed based upon i) the stationary phase method to describe the field after reflection at a plate edge, ii) on the computation of modal reflection coefficients for an arbitrary incidence relative to the edge and iii) on the Fraunhofer approximation to account for the finite size of the source. The stationary phase method allows us to easily express the amplitude of reflected modes, that is to say, the way waves spread, including reflections involving mode conversions. The computation of modal reflection coefficients for plane GW at oblique incidence was recently treated in the literature and our work for this very problem simply consisted in adapting it to the SAFE calculation we use to compute modal solutions. The overall computation of the direct and reflected contributions is numerically very efficient. Once the total field is computed at a given frequency, the time-dependent field is obtained by simple Fourier synthesis.

  3. Compact ring FEL as a source of high-power infrared radiation

    Science.gov (United States)

    Shevchenko, O. A.; Matveenko, A. N.; Vinokurov, N. A.

    2009-05-01

    Ring FELs [N.A. Vinokurov, O.A. Shevchenko, Nucl. Instr. And Meth. A 528 (2004) 491] were proposed mainly to improve the quality of radiation of X-ray FELs. Their main advantage is the absence of mirrors. It appears that this advantage is also useful for high-power FELs. Another reason to build infrared ring FEL is the proof of principle for shorter wavelength FELs. Therefore, we considered the scheme of infrared ring FEL which requires ERL with beam energy 50 MeV. Using extensive simulations we developed requirements for electron beam parameters and magnetic system of ring FEL. In spite of rather compact design such FEL may provide more than 10 kW average power.

  4. SU-E-T-253: Open-Source Automatic Software for Quantifying Biological Assays of Radiation Effects

    Energy Technology Data Exchange (ETDEWEB)

    Detappe, A [University of Lyon (France); Dana-Farber Cancer Institute, Boston, MA (United States); Korideck, H [Dana-Farber Cancer Institute, Boston, MA (United States); Makrigiorgos, G; Berbeco, R [Dana-Farber Cancer Institute, Boston, MA (United States); Brigham and Women' s Hospital, Boston, MA (United States)

    2014-06-01

    Purpose: Clonogenic cell survival is a common assay for quantifying the effect of drugs and radiation. Manual counting of surviving colonies can take 30–90seconds per plate, a major limitation for large studies. Currently available automatic counting tools are not easily modified for radiation oncology research. Our goal is to provide an open-source toolkit for precise, accurate and fast analysis of biological assays in radiation oncology. Methods: As an example analysis, we used HeLa cells incubated with gadolinium nanoparticles prior to irradiation. After treatment, the cells are grown for 14days to allow for colony formation. To analyze the colony growth, we capture images of each dish for archiving and automatic computer-based analysis. A FujifilmX20 camera is placed at the top of a box setup, 20cm above the sample, which is backlit by a LED lamp placed at the bottom of the box. We use a Gaussian filter (width=1.3mm) and color threshold (19–255). The minimum size for a colony to be counted is 1mm. For this example, 20 dishes with a large range of colonies were analyzed. Each dish was counted 3 times manually by 3 different users and then compared to our counter. Results: Automatic counting of cell colonies takes an average of 7seconds, enabling the analysis process to be accelerated 4–12 times. The average precision of the automatic counter was 1.7%. The Student t-test demonstrated the non-significant differences between the two counting methods (p=0.64). The ICC demonstrated the reliability of each method with ICC>0.999 (automatic) and ICC=0.95 (manual). Conclusion: We developed an open-source automatic toolkit for the analysis of biological assays in radiation oncology and demonstrated the accuracy, precision and effort savings for clonogenic cell survival quantification. This toolkit is currently being used in two laboratories for routine experimental analysis and will be made freely available on our departmental website.

  5. Evaluating laser-driven Bremsstrahlung radiation sources for imaging and analysis of nuclear waste packages.

    Science.gov (United States)

    Jones, Christopher P; Brenner, Ceri M; Stitt, Camilla A; Armstrong, Chris; Rusby, Dean R; Mirfayzi, Seyed R; Wilson, Lucy A; Alejo, Aarón; Ahmed, Hamad; Allott, Ric; Butler, Nicholas M H; Clarke, Robert J; Haddock, David; Hernandez-Gomez, Cristina; Higginson, Adam; Murphy, Christopher; Notley, Margaret; Paraskevoulakos, Charilaos; Jowsey, John; McKenna, Paul; Neely, David; Kar, Satya; Scott, Thomas B

    2016-11-15

    A small scale sample nuclear waste package, consisting of a 28mm diameter uranium penny encased in grout, was imaged by absorption contrast radiography using a single pulse exposure from an X-ray source driven by a high-power laser. The Vulcan laser was used to deliver a focused pulse of photons to a tantalum foil, in order to generate a bright burst of highly penetrating X-rays (with energy >500keV), with a source size of waste materials. This feasibility study successfully demonstrated non-destructive radiography of encapsulated, high density, nuclear material. With recent developments of high-power laser systems, to 10Hz operation, a laser-driven multi-modal beamline for waste monitoring applications is envisioned. Copyright © 2016. Published by Elsevier B.V.

  6. Tags and seals to strengthen arms control verification

    Energy Technology Data Exchange (ETDEWEB)

    DeVolpi, A.

    1990-10-03

    Tags and seals have long been recognized as important tools in arms control. The trend in control of armaments is to limit militarily significant equipment that is capable of being verified through direct and cooperative means, chiefly on-site inspection or monitoring. Although this paper will focus on the CFE treaty, the role of tags and seals for other treaties will also be addressed. Published technology and concepts will be reviewed, based on open sources. Arms control verification tags are defined as unique identifiers designed to be tamper-revealing; in that respect, seals are similar, being used as indicators of unauthorized access. Tamper-revealing tags are intended as single-point markers, seals for two-point couplings, and nets for volume containment. Seals usually bind two separate components, such as a hatch or flange that provides access to a secure compartment or a valve that controls fluid flow. A tamper-revealing net might be comprised of a coupled fiberoptic bundle wrapped around an object. Sometimes the term ``seal`` is used to denote the tamper-revealing feature of a tag that is attached to a surface, but in this paper the tamper-indicating connection is considered to be part of the tag concept itself.

  7. Catch history of ringed seals (Phoca hispida in Canada

    Directory of Open Access Journals (Sweden)

    Randall R Reeves

    1998-06-01

    Full Text Available The ringed seal (Phoca hispida has always been a staple in the diet and household economy of Inuit in Canada. The present paper was prepared at the request of the NAMMCO Scientific Committee to support their assessment of ringed seal stocks in the North Atlantic Basin and adjacent arctic and subarctic waters. Specifically, our objective was to evaluate recent and current levels of use of ringed seals by Canadian Inuit. Annual removals probably were highest (possibly greater than 100,000 in the 1960s and 1970s, a period when sealskin prices were particularly strong. Catches declined substantially in the 1980s following a collapse in sealskin prices, presumably related to the European trade ban on skins from newborn harp and hooded seals (Phoca groenlandica and Cystophora cristata, respectively. Recent catch levels throughout Canada (1980s and early 1990s are believed to be in the order of 50,000 to 65,000 ringed seals, with a total average annual kill (including hunting loss in the high tens of thousands. No reliable system is in place to monitor catches of ringed seals, so any estimate must be derived from a heterogeneous array of sources.

  8. On the use of HDR Co60 source with the MammoSite(®) Radiation Therapy System.

    Science.gov (United States)

    Baltas, D; Lymperopoulou, G; Zamboglou, N

    2008-12-01

    This work summarizes Monte Carlo results in order to evaluate the potential of using HDR Co60 sources in accelerated partial breast irradiation (APBI) with the MammoSite(®) applicator. Simulations have been performed using the MCNP5 Monte Carlo Code, in simple geometries comprised of two concentric spheres; the internal consisting of selected concentrations, C, of a radiographic contrast solution in water (Omnipaque 300(™) ) to simulate the MammoSite balloon and the external consisting of water to simulate surrounding tissue. The magnitude of the perturbation of delivered dose due to the radiographic contrast medium used in the MammoSite(®) applicator is calculated. At the very close vicinity of the balloon surface, a dose build-up region is observed, which leads to a dose overestimation by the treatment planning system (TPS) which depends on Omnipaque(™) 300 solution concentration (and is in order of 2.3%, 3.0%, and 4.5%, respectively, at 1 mm away from the balloon - water interface, for C=10%, 15%, and 20%). However, dose overestimation by the TPS is minimal for points lying at the prescription distance (d=1 cm) or beyond, for all simulated concentrations and radii of MammoSite(®) balloon. An analytical estimation of the integral dose outside the CTV in the simple geometries simulated shows that dose to the breast for MammoSite(®) applications is expected to be comparable using HDR Co60 and Ir192 sources, and higher than that for Yb169. The higher enegies of Co60 sources result to approximately twice radiation protection requirements as compared to Ir169 sources. However, they allow for more accurate dosimetry calculation with currently used treatment planning algorithms for Co60 sources, compared to Ir169. © 2008 American Association of Physicists in Medicine.

  9. L-shell spectroscopic diagnostics of radiation from krypton HED plasma sources

    Energy Technology Data Exchange (ETDEWEB)

    Petkov, E. E., E-mail: emilp@unr.edu; Safronova, A. S.; Kantsyrev, V. L.; Shlyaptseva, V. V. [University of Nevada, Reno, Nevada 89557 (United States); Rawat, R. S.; Tan, K. S. [National Institute of Education, Nanyang Technological University, Singapore 637616 (Singapore); Beiersdorfer, P.; Brown, G. V. [Lawrence Livermore National Laboratory, Livermore, California 94550 (United States); Hell, N. [Lawrence Livermore National Laboratory, Livermore, California 94550 (United States); Dr. Remeis-Sternwarte and ECAP, Universität Erlangen-Nürnberg, 96049 Bamberg (Germany)

    2016-11-15

    X-ray spectroscopy is a useful tool for diagnosing plasma sources due to its non-invasive nature. One such source is the dense plasma focus (DPF). Recent interest has developed to demonstrate its potential application as a soft x-ray source. We present the first spectroscopic studies of krypton high energy density plasmas produced on a 3 kJ DPF device in Singapore. In order to diagnose spectral features, and to obtain a more comprehensive understanding of plasma parameters, a new non-local thermodynamic equilibrium L-shell kinetic model for krypton was developed. It has the capability of incorporating hot electrons, with different electron distribution functions, in order to examine the effects that they have on emission spectra. To further substantiate the validity of this model, it is also benchmarked with data gathered from experiments on the electron beam ion trap (EBIT) at Lawrence Livermore National Laboratory, where data were collected using the high resolution EBIT calorimeter spectrometer.

  10. 9 CFR 381.98 - Official seal.

    Science.gov (United States)

    2010-01-01

    ... 9 Animals and Animal Products 2 2010-01-01 2010-01-01 false Official seal. 381.98 Section 381.98... Certificates; Certification Procedures § 381.98 Official seal. The official mark for use in sealing means of... and a serial number as shown below, and any seals approved by the Administrator for applying such mark...

  11. 36 CFR 901.6 - Seal.

    Science.gov (United States)

    2010-07-01

    ... 36 Parks, Forests, and Public Property 3 2010-07-01 2010-07-01 false Seal. 901.6 Section 901.6... CORPORATION § 901.6 Seal. The Corporation may adopt a corporate seal which shall have the name of the Corporation and year of incorporation printed upon it. The seal may be used by causing it or a facsimile...

  12. 39 CFR 3002.3 - Official seal.

    Science.gov (United States)

    2010-07-01

    ... 39 Postal Service 1 2010-07-01 2010-07-01 false Official seal. 3002.3 Section 3002.3 Postal Service POSTAL REGULATORY COMMISSION PERSONNEL ORGANIZATION § 3002.3 Official seal. (a) Authority. The Seal described in this section is hereby established as the official seal of the Postal Rate Commission...

  13. 7 CFR 29.34 - Sample seal.

    Science.gov (United States)

    2010-01-01

    ... 7 Agriculture 2 2010-01-01 2010-01-01 false Sample seal. 29.34 Section 29.34 Agriculture Regulations of the Department of Agriculture AGRICULTURAL MARKETING SERVICE (Standards, Inspections, Marketing... INSPECTION Regulations Definitions § 29.34 Sample seal. A seal approved by the Director for sealing official...

  14. 14 CFR 65.133 - Seal.

    Science.gov (United States)

    2010-01-01

    ... 14 Aeronautics and Space 2 2010-01-01 2010-01-01 false Seal. 65.133 Section 65.133 Aeronautics and...: AIRMEN OTHER THAN FLIGHT CREWMEMBERS Parachute Riggers § 65.133 Seal. Each certificated parachute rigger must have a seal with an identifying mark prescribed by the Administrator, and a seal press. After...

  15. 7 CFR 29.35 - Lot seal.

    Science.gov (United States)

    2010-01-01

    ... 7 Agriculture 2 2010-01-01 2010-01-01 false Lot seal. 29.35 Section 29.35 Agriculture Regulations of the Department of Agriculture AGRICULTURAL MARKETING SERVICE (Standards, Inspections, Marketing... INSPECTION Regulations Definitions § 29.35 Lot seal. A seal approved by the Director for sealing lots of...

  16. Radiation hardening of diagnostics

    Science.gov (United States)

    Siemon, R. E.

    The world fusion program has advanced to the stage where it is appropriate to construct a number of devices for the purpose of burning DT fuel. In these next-generation experiments, the expected flux and fluence of 14 MeV neutrons and associated gamma rays will pose a significant challenge to the operation and diagnostics of the fusion device. Radiation effects include structural damage to materials such as vacuum windows and seals, modifications to electrical properties such as electrical conductivity and dielectric strength and impaired optical properties such as reduced transparency and luminescence of windows and fiber optics during irradiation. In preparation for construction and operation of these new facilities, the fusion diagnostics community needs to work with materials scientists to develop a better understanding of radiation effects, and to undertake a testing program aimed at developing workable solutions for this multi-faceted problem. A unique facility to help in this regard is the Los Alamos Spallation Radiation Effects Facility, a neutron source located at the beam stop of the world's most powerful accelerator, the Los Alamos Meson Physics Facility (LAMPF). The LAMPF proton beam generates 10(exp 16) neutrons per second because of spallation'reactions when the protons collide with the copper nuclei in the beam stop.

  17. Generation of auroral kilometric radiation by a finite-size source in a dipole magnetic field

    Energy Technology Data Exchange (ETDEWEB)

    Burinskaya, T. M., E-mail: tburinsk@iki.rssi.ru; Shevelev, M. M. [Russian Academy of Sciences, Space Research Institute (Russian Federation)

    2016-10-15

    Generation, amplification, and propagation of auroral kilometric radiation in a narrow three-dimensional plasma cavity in which a weakly relativistic electron beam propagates is studied in the geometrical optics approximation. It is shown that the waves that start with a group velocity directed earthward and have optimal relation between the wave vector components determining the linear growth rate and the wave residence time inside the amplification region undergo the largest amplification. Taking into account the longitudinal velocity of fast electrons results in the shift of the instability domain toward wave vectors directed to the Earth and leads to a change in the dispersion relation, due to which favorable conditions are created for the generation of waves with frequencies above the cutoff frequency for the cold background plasma at the wave generation altitude. The amplification factor for these waves is lower than for waves that have the same wave vectors but are excited by the electron beams with lower velocities along the magnetic field. For waves excited at frequencies below the cutoff frequency of the background plasma at the generation altitude, the amplification factor increases with increasing longitudinal electron velocity, because these waves reside for a longer time in the amplification region.

  18. Alaska Harbor Seal Glacial Surveys

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Floating glacial ice serves as a haul-out substrate for a significant number (10-15%) of Alaskan harbor seals, and thus surveying tidewater glacial fjords is an...

  19. Northern Fur Seal Food Habits

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — This data set contains food habits samples, usually scats, collected opportunistically on northern fur seal rookeries and haulouts in Alaska from 1987 to present....

  20. Construction of a photochemical reactor combining a CCD spectrophotometer and a LED radiation source.

    Science.gov (United States)

    Gombár, Melinda; Józsa, Éva; Braun, Mihály; Ősz, Katalin

    2012-10-01

    An inexpensive photoreactor using LED light sources and a fibre-optic CCD spectrophotometer as a detector was built by designing a special cell holder for standard 1.000 cm cuvettes. The use of this device was demonstrated by studying the aqueous photochemical reaction of 2,5-dichloro-1,4-benzoquinone. The developed method combines the highly quantitative data collection of CCD spectrophotometers with the possibility of illuminating the sample independently of the detecting light beam, which is a substantial improvement of the method using diode array spectrophotometers as photoreactors.

  1. Chip and scrub seal field test results for Hwy 17 and Hwy 35.

    Science.gov (United States)

    2009-11-09

    This report contains field test results from two pavements located in Mississippi containing chip seals and scrub seals. Limestone aggregate from the same source was used with PASS-CR emulsion. The pavements were tested at three intervals. One or bot...

  2. Inflatable O-ring seal would ease closing of hatch cover plate

    Science.gov (United States)

    Neary, K. J.

    1966-01-01

    Inflatable O-ring seal provides positive sealing means that does not require the manual exertion of a large compressive force during opening or closing of a rotary-type hatch cover plate. The O-ring is deflated during opening and closing and inflated after closure by a gas pressure source.

  3. Simultaneous event-specific estimates of transport, loss, and source rates for relativistic outer radiation belt electrons

    Science.gov (United States)

    Schiller, Q.; Tu, W.; Ali, A. F.; Li, X.; Godinez, H. C.; Turner, D. L.; Morley, S. K.; Henderson, M. G.

    2017-03-01

    The most significant unknown regarding relativistic electrons in Earth's outer Van Allen radiation belt is the relative contribution of loss, transport, and acceleration processes within the inner magnetosphere. Detangling each individual process is critical to improve the understanding of radiation belt dynamics, but determining a single component is challenging due to sparse measurements in diverse spatial and temporal regimes. However, there are currently an unprecedented number of spacecraft taking measurements that sample different regions of the inner magnetosphere. With the increasing number of varied observational platforms, system dynamics can begin to be unraveled. In this work, we employ in situ measurements during the 13-14 January 2013 enhancement event to isolate transport, loss, and source dynamics in a one-dimensional radial diffusion model. We then validate the results by comparing them to Van Allen Probes and Time History of Events and Macroscale Interactions during Substorms observations, indicating that the three terms have been accurately and individually quantified for the event. Finally, a direct comparison is performed between the model containing event-specific terms and various models containing terms parameterized by geomagnetic index. Models using a simple 3/Kp loss time scale show deviation from the event-specific model of nearly 2 orders of magnitude within 72 h of the enhancement event. However, models using alternative loss time scales closely resemble the event-specific model.

  4. Marangoni convective MHD flow of SWCNT and MWCNT nanoliquids due to a disk with solar radiation and irregular heat source

    Science.gov (United States)

    Mahanthesh, B.; Gireesha, B. J.; Shashikumar, N. S.; Shehzad, S. A.

    2017-10-01

    Present study addresses the Marangoni transport of dissipating SWCNT and MWCNT nanofluids under the influence of magnetic force and radiation. A novel exponential space dependent heat source is considered. The flow is generated due to a disk with surface tension created by thermal gradient. The partial differential equations system governing the flow of carbon-water nanoliquids and heat transfer through Marangoni convection is established. Subsequent system is reduced to nonlinear ordinary boundary value problem via generalized Karman transformations. Numerical solutions are developed of the arising nonlinear problem via Runge-Kutta based shooting approach. Impacts of embedded parameters are focused on Nusselt number, velocity and heat transport distributions through graphical illustrations. Our simulations figured out that the heat transfer rate increased via Marangoni convection; however it is decayed by applied magnetic force. The temperature of SWCNT-H2O nanoliquid dominates MWCNT-H2O nanoliquid.

  5. Blackbody Sources for the Range 100 K to 3500 K for Precision Measurements in Radiometry and Radiation Thermometry

    Science.gov (United States)

    Sapritsky, V. I.; Khlevnoy, B. B.; Khromchenko, V. B.; Ogarev, S. A.; Morozova, S. P.; Lisiansky, B. E.; Samoylov, M. L.; Shapoval, V. I.; Sudarev, K. A.

    2003-09-01

    The paper presents a detailed review of precision blackbodies that are low-, medium-, and high-temperature range sources developed at VNIIOFI during the past 30 years. Low-temperature blackbodies were developed for calibration facilities of spaceborne instruments. Medium-temperature blackbodies are used for radiance temperature and IR radiometric measurements. The high-temperature pyrolitic graphite blackbodies BB3200 and BB3500 were developed for world-leading metrology centers as NIST (USA), PTB (Germany), NPL (Great Britain), VNIIOFI (Russia), CNAM (France) and others for the realization and dissemination of radiometric and radiation temperature scales. The latest modification of the high-temperature blackbody BB3500MP, the large-aperture version (with an opening of up to 16 mm) of the famous BB3500, suitable for holding large fixed-point cells with high-temperature TiC-C and ZrC-C eutectics, is under development.

  6. Measuring circular dichroism in a capillary cell using the b23 synchrotron radiation CD beamline at diamond light source.

    Science.gov (United States)

    Jávorfi, Tamás; Hussain, Rohanah; Myatt, Daniel; Siligardi, Giuliano

    2010-01-01

    Synchrotron radiation circular dichroism (SRCD) is a well-established method in structural biology. The first UV-VIS beamline dedicated to circular dichroism at Diamond Light Source, a third generation synchrotron facility in South Oxfordshire, has recently become operational and it is now available for the user community. Herein we present an important application of SRCD: the CD measurement of protein solutions in fused silica rectangular capillary cells. This was achieved without the use of any lens between the photoelastic modulator and the photomultiplier tube detectors by exploiting the high photon flux of the collimated beam that can be as little as half a millimeter squared. Measures to minimize or eliminate vacuum-UV protein denaturation effects are discussed. The CD spectra measured in capillaries is a proof of principle to address CD measurements in microdevice systems using the new B23 SRCD beamline. © 2010 Wiley-Liss, Inc.

  7. Direct Radiative Effect and Heating Rate of black carbon aerosol: high time resolution measurements and source-identified forcing effects

    Science.gov (United States)

    Ferrero, Luca; Mocnik, Grisa; Cogliati, Sergio; Comi, Alberto; Degni, Francesca; Di Mauro, Biagio; Colombo, Roberto; Bolzacchini, Ezio

    2016-04-01

    Black carbon (BC) absorbs sunlight in the atmosphere heating it. However, up to now, heating rate (HR) calculations from the divergence of the net radiative flux with altitude or from the modelling activity are too sparse. This work fills the aforementioned gap presenting a new methodology based on a full set of physical equations to experimentally determine both the radiative power density absorbed into a ground-based atmospheric layer (ADRE), and the consequent HR induced by the absorptive component of aerosol. In urban context, it is essentially related to the BC. The methodology is also applicable to natural components (i.e. dust) and is obtained solving the first derivative of the main radiative transfer equations. The ADRE and the consequent HR can be determined coupling spectral aerosol absorption measurements with the spectrally resolved measurements of the direct, diffuse downward radiation and the surface reflected radiance components. Moreover, the spectral absorption of BC aerosol allows its source apportionment (traffic and biomass burning (BB)) allowing the same apportionment on HR. This work reports one year of high-time resolution measurements (5 min) of sunlight absorption and HR induced by BC aerosol over Milan. A unique sampling site was set up from March 2015 with: 1) Aethalometer (AE-31, Magee Scientific, 7-λ), 2) the Multiplexer-Radiometer-Irradiometer which detects downward and reflected radiance (350-1000 nm in 3648 spectral bands) coupled with a rotating shadow-band to measure spectrally-resolved global and diffuse radiation (thus direct), 3) a meteorological station (LSI-Lastem) equipped with 3 pyranometers (global, diffuse and refrected radiation; 300-3000 nm), a thermohygrometer, a barometer, an anemometer, 4) condensation and optical particle counters (TSI 3775 and Grimm 1.107), 5) low volume sampler (FAI Hydra dual sampler, PM2.5 and PM10) for sample collection and chemistry determination. Results concerning the radiative power

  8. sources

    Directory of Open Access Journals (Sweden)

    Shu-Yin Chiang

    2002-01-01

    Full Text Available In this paper, we study the simplified models of the ATM (Asynchronous Transfer Mode multiplexer network with Bernoulli random traffic sources. Based on the model, the performance measures are analyzed by the different output service schemes.

  9. Obtention of brachytherapy seeds by sealing process using polymer; Obtencao de sementes de braquiterapia pelo processo de selagem com polimero

    Energy Technology Data Exchange (ETDEWEB)

    Lana, Diogo Alberto P.D.; Ferraz, Wilmar B.; Santos, Ana Maria M., E-mail: amms@cdtn.br [Centro de Desenvolvimento da Tecnologia Nuclear (CDTN/CNEN-MG), Belo Horizonte, MG (Brazil); Carvalho, Luiz Claudio F.M. Garcia [Universidade Federal de Minas Gerais (UFMG), Belo Horizonte, MG (Brazil)

    2012-08-15

    Brachytherapy is an advanced cancer treatment where radioactive seeds or sources are placed near or directly into the tumor thus reducing the radiation exposure in the surrounding healthy tissues. Several kinds of seeds have been developed in order to obtain a better dose distribution around them and with a lower cost manufacturing. These seeds consist of an encapsulation (titanium or stainless steel tube), a radionuclide carrier, and X-ray marker. The usual sealing process of the seeds is done with laser welding, but this process can promote radionuclide volatilization. In this paper, we present a new sealing process using epoxy resin and characterizations of two epoxy resins. These resins were characterized by Fourier transform infrared spectroscopic (FTIR), ultraviolet-visible spectroscopy (UV-vis) and differential scanning calorimetry (DSC). Interactions of the resins and of the sealed seeds in a simulated body fluid (SBF) were evaluated by scanning electron microscopy (SEM), energy dispersive X-ray spectroscopy (EDS), and by a counting gamma-rays. (author)

  10. Radiation survey of aircraft and heavy machinery scrap.

    Science.gov (United States)

    Idriss, Hajo; Salih, Isam; Gumaa, Elsadig; Yassin, Abbas; Yousif, E H; Abdel Hamid, Saad Eldeen M; Sam, A K

    2012-12-01

    This study was conducted primarily to survey aircraft and heavy machinery at 30 locations within Khartoum State using handheld radiation survey meters to detect and identify any radiation sources that might be present and to estimate radiation dose levels. The survey has resulted in detection of 16 sealed sources of (90)Sr and one of (226)Ra in aircraft scrap. Of course, (90)Sr sources are used in military aircraft as temperature sensors while (226)Ra is used for indicating fuel levels. These sources were found intact without spreading radioactivity contamination; however, none was detected in heavy machine scrap. The levels of radiation dose measured at 0.1m from the source fall within the range of 25.1-40.2 μSv/h with an average value of 33.52 ± 4.06 μSv/h. These orphan sources have been separated from the scrap, tested for possible leakage, conditioned and stored in waste management facility. The result of this study has revealed without doubt that the scrap constitute a serious source of public exposure and highlights the importance of legislation making radiation monitoring of scrap in the country mandatory before it is sold to metal industry for reprocessing. Copyright © 2012 Elsevier Ltd. All rights reserved.

  11. Laser-driven electron beam and radiation sources for basic, medical and industrial sciences

    Science.gov (United States)

    NAKAJIMA, Kazuhisa

    2015-01-01

    To date active research on laser-driven plasma-based accelerators have achieved great progress on production of high-energy, high-quality electron and photon beams in a compact scale. Such laser plasma accelerators have been envisaged bringing a wide range of applications in basic, medical and industrial sciences. Here inheriting the groundbreaker’s review article on “Laser Acceleration and its future” [Toshiki Tajima, (2010)],1) we would like to review recent progress of producing such electron beams due to relativistic laser-plasma interactions followed by laser wakefield acceleration and lead to the scaling formulas that are useful to design laser plasma accelerators with controllability of beam energy and charge. Lastly specific examples of such laser-driven electron/photon beam sources are illustrated. PMID:26062737

  12. An isotopic analysis of ionising radiation as a source of sulphuric acid

    DEFF Research Database (Denmark)

    Enghoff, Martin Andreas Bødker; Bork, Nicolai Christian; Hattori, S.

    2012-01-01

    a missing source. In this study the production of sulphuric acid from SO2 through a number of different pathways is investigated. The production methods are standard gas phase oxidation by OH radicals produced by ozone photolysis with UV light, liquid phase oxidation by ozone, and gas phase oxidation...... initiated by gamma rays. The distributions of stable sulphur isotopes in the products and substrate were measured using isotope ratio mass spectrometry. All methods produced sulphate enriched in S-34 and we find an enrichment factor (delta S-34) of 8.7 +/- 0.4 parts per thousand (1 standard deviation......) for the UV-initiated OH reaction. Only UV light (Hg emission at 253.65 nm) produced a clear non-mass-dependent excess of S-33. The pattern of isotopic enrichment produced by gamma rays is similar, but not equal, to that produced by aqueous oxidation of SO2 by ozone. This, combined with the relative yields...

  13. An isotope view on ionising radiation as a source of sulphuric acid

    DEFF Research Database (Denmark)

    Enghoff, Martin Andreas Bødker; Bork, Nicolai Christian; Hattori, S.

    2012-01-01

    oxidation initiated by gamma rays. The distributions of stable sulphur isotopes in the products and substrate were measured using isotope ratio mass spectrometry. All methods produced sulphate enriched in 34S and we find a δ34S value of 8.7 ± 0.4‰ (1 standard deviation) for the UV...... a missing source. In this study the production of sulphuric acid from SO2 through a number of different pathways is investigated. The production methods are standard gas phase oxidation by OH radicals produced by ozone photolysis with UV light, liquid phase oxidation by ozone, and gas phase......-initiated OH reaction. Only UV light (Hg emission at 253.65 nm) produced a clear non-mass-dependent excess of 33S. The pattern of isotopic enrichment produced by gamma rays is similar, but not equal, to that produced by aqueous oxidation of SO2 by ozone. This, combined with the relative...

  14. Evaluating laser-driven Bremsstrahlung radiation sources for imaging and analysis of nuclear waste packages

    Energy Technology Data Exchange (ETDEWEB)

    Jones, Christopher P., E-mail: cj0810@bristol.ac.uk [Interface Analysis Centre, HH Wills Physics Laboratory, Tyndall Avenue, Bristol BS8 1TL (United Kingdom); Brenner, Ceri M. [Central Laser Facility, STFC, Rutherford Appleton Laboratory, Didcot, Oxon OX11 0QX (United Kingdom); Stitt, Camilla A. [Interface Analysis Centre, HH Wills Physics Laboratory, Tyndall Avenue, Bristol BS8 1TL (United Kingdom); Armstrong, Chris; Rusby, Dean R. [Central Laser Facility, STFC, Rutherford Appleton Laboratory, Didcot, Oxon OX11 0QX (United Kingdom); Department of Physics, SUPA, University of Strathclyde, Glasgow G4 0NG (United Kingdom); Mirfayzi, Seyed R. [Centre for Plasma Physics, Queen' s University Belfast, Belfast BT7 1NN (United Kingdom); Wilson, Lucy A. [Central Laser Facility, STFC, Rutherford Appleton Laboratory, Didcot, Oxon OX11 0QX (United Kingdom); Alejo, Aarón; Ahmed, Hamad [Centre for Plasma Physics, Queen' s University Belfast, Belfast BT7 1NN (United Kingdom); Allott, Ric [Central Laser Facility, STFC, Rutherford Appleton Laboratory, Didcot, Oxon OX11 0QX (United Kingdom); Butler, Nicholas M.H. [Department of Physics, SUPA, University of Strathclyde, Glasgow G4 0NG (United Kingdom); Clarke, Robert J.; Haddock, David; Hernandez-Gomez, Cristina [Central Laser Facility, STFC, Rutherford Appleton Laboratory, Didcot, Oxon OX11 0QX (United Kingdom); Higginson, Adam [Department of Physics, SUPA, University of Strathclyde, Glasgow G4 0NG (United Kingdom); Murphy, Christopher [Department of Physics, University of York, York YO10 5DD (United Kingdom); Notley, Margaret [Central Laser Facility, STFC, Rutherford Appleton Laboratory, Didcot, Oxon OX11 0QX (United Kingdom); Paraskevoulakos, Charilaos [Interface Analysis Centre, HH Wills Physics Laboratory, Tyndall Avenue, Bristol BS8 1TL (United Kingdom); Jowsey, John [Ground Floor North B582, Sellafield Ltd, Seascale, Cumbria CA20 1PG (United Kingdom); and others

    2016-11-15

    Highlights: • X-ray generation was achieved via laser interaction with a tantalum thin foil target. • Picosecond X-ray pulse from a sub-mm spot generated high resolution images. • MeV X-ray emission is possible, permitting analysis of full scale waste containers. • In parallel neutron emission of 10{sup 7}–10{sup 9} neutrons per steradian per pulse was attained. • Development of a 10 Hz diode pumped laser system for waste monitoring is envisioned. - Abstract: A small scale sample nuclear waste package, consisting of a 28 mm diameter uranium penny encased in grout, was imaged by absorption contrast radiography using a single pulse exposure from an X-ray source driven by a high-power laser. The Vulcan laser was used to deliver a focused pulse of photons to a tantalum foil, in order to generate a bright burst of highly penetrating X-rays (with energy >500 keV), with a source size of <0.5 mm. BAS-TR and BAS-SR image plates were used for image capture, alongside a newly developed Thalium doped Caesium Iodide scintillator-based detector coupled to CCD chips. The uranium penny was clearly resolved to sub-mm accuracy over a 30 cm{sup 2} scan area from a single shot acquisition. In addition, neutron generation was demonstrated in situ with the X-ray beam, with a single shot, thus demonstrating the potential for multi-modal criticality testing of waste materials. This feasibility study successfully demonstrated non-destructive radiography of encapsulated, high density, nuclear material. With recent developments of high-power laser systems, to 10 Hz operation, a laser-driven multi-modal beamline for waste monitoring applications is envisioned.

  15. Seal testing of large diameter rocket motors

    Science.gov (United States)

    Moore, N. B.; Hellums, John W.; Bechtel, Thomas; Kittredge, Ken; Crossfield, Craig

    1991-01-01

    This investigative program examines leakage testing of elastomeric O-ring seals for a solid rocket casing and provides direction towards an improved nondestructive postassembly test. It also details test equipment for the Space Shuttle systems solid rocket boosters (SRB). The results are useful to designers of hardware for pressure containment vessels which use O-ring seals. Using several subscale seal and groove configuration test fixtures equipped with either two or three O-ring seals in series, seal integrity is investigated with both a pressure decay and flowmeter methods. Both types of test equipment adequately detect the practical range of expected seal leak rates of 1 to 0.0001 sccs. The flowmeter leak test equipment appears to reduce testing time substantially. Limited seal leakage testing is performed on full-sized rocket motor segment seals, a pre-Challenger short stack, providing comparison of bore seals to test specimen bore and face seals. The conclusions are that seal reliability, verified via a performance pressure test, can be affected by temperature, quantity of grease, test pressure, and seal pressure load direction. Potential seal failure scenarios including contamination, seal damage, and sealing surface damage are discussed. Recommendations are made for an improved test procedure.

  16. UV radiation, vitamin D, and cancer: how to measure the vitamin D synthetic capacity of UV sources?

    Science.gov (United States)

    Terenetskaya, Irina; Orlova, Tatiana

    2005-09-01

    UV irradiation is widely used in phototherapy. Regardless of the fact that UV overexposure is liable to cause adverse health effect, in appropriate doses UV radiation initiates synthesis of vitamin D in skin that is absolutely essential for human health. As it proved, most people in northern industrial countries have a level of vitamin D in their bodies that is insufficient for optimum health, especially in winter. These low levels of vitamin D are now known to be associated with a wide spectrum of serious disease much of which leads on to premature death. The diseases associated with D deficiency involve more than a dozen types of cancer including colon, breast and prostate, as well as the classic bone diseases: rickets, osteoporosis and osteomalacia. Irradiation with artificial UV sources can prevent the vitamin D deficiency. However, in view of different irradiation spectra of UV lamps, their ability to initiate vitamin D synthesis is different. The reliable method based on an in vitro model of vitamin D synthesis has been developed for direct measurement in situ of the vitamin D synthetic capacity of artificial UV sources during a phototherapeutic procedure

  17. X-ray optics developments at the APS for the third generation of high-energy synchrotron radiation sources.

    Science.gov (United States)

    Mills, D M

    1997-05-01

    Third-generation hard-X-ray synchrotron radiation sources simultaneously provide both a need and an opportunity for the development of new short-wavelength optical components. The high power and power densities of the insertion-device-produced X-ray beams have forced researchers to consider what may seem like exotic approaches, such as cryogenically cooled silicon and highly perfect diamond crystals, to mitigate thermal distortions in the first optical components. Once the power has been successfully filtered while maintaining the high beam brilliance, additional specialized optical components can be inserted into the monochromatic beam that take advantage of that brilliance. This paper reviews the performance of such optical components that have been designed, fabricated and tested at the Advanced Photon Source, starting with high-heat-load components and followed by examples of several specialized devices, such as an meV resolution (in-line) monochromator, a high-energy X-ray phase retarder and a phase-zone plate with submicrometer focusing capability.

  18. Aerosol black carbon at an urban site-Srinagar, Northwestern Himalaya, India: Seasonality, sources, meteorology and radiative forcing

    Science.gov (United States)

    Bhat, Mudasir Ahmad; Romshoo, Shakil Ahmad; Beig, Gufran

    2017-09-01

    Black carbon (BC) mass concentration was measured first-time at a high altitude urban site-Srinagar (1600 m asl), in northwestern Himalaya, India using an Aethalometer during 2013 to study temporal variations (monthly, diurnal and seasonal), meteorological influences, source and its radiative forcing. Diurnal variations with two peaks (at 8-10 h and 20-23 h) and two dips (at 13-17 h and 0-3 h) were observed throughout the year with varying magnitude. November and April showed the highest (13.6 μg/m3) and the lowest (3.4 μg/m3) mean monthly BC concentration respectively. Seasonally, autumn displayed the highest (9.2 μg/m3) and spring the lowest (3.5 μg/m3) mean BC concentration. Annual average BC concentration was quite higher (6 μg/m3) than those reported for other high altitude stations. Wind speed, Minimum temperature and total precipitation showed a clear negative correlation with BC (r = -0.63, -0.51 and -0.55 respectively), while as, the evening relative humidity showed positive correlation (r = 0.56). During autumn, spring and winter seasons, the main source of BC at Srinagar is the biomass burning, while during summer season, equal contribution of BC is from fossil fuel and biomass burning. Back trajectory simulations revealed that, except summer, westerly air masses are the dominant winds, transporting BC from central Asia, west Asia, south Asia, Africa and some parts of Europe to Srinagar adding to its local sources. Clear-sky short wave radiative forcing of atmosphere due to BC was highest (58.2 W m-2) during autumn which leads to the increase in lower atmospheric heating rate by 1.6 K/d. The high concentration of BC observed over the high-altitude Himalayan Kashmir region has serious implications for the regional climate, hydrology and cryosphere which needs to be investigated.

  19. Radiation dose levels in pediatric chest CT: experience in 499 children evaluated with dual-source single-energy CT

    Energy Technology Data Exchange (ETDEWEB)

    Martine, Remy-Jardin; Colas, Lucie; Jean-Baptiste, Faivre; Remy, Jacques [CHU Lille (EA 2694) University of Lille, Department of Thoracic Imaging, Hospital Calmette, Lille (France); Santangelo, Teresa [CHU Lille (EA 2694) University of Lille, Department of Thoracic Imaging, Hospital Calmette, Lille (France); Bambino Gesu Children' s Hospital, Department of Imaging, Rome (Italy); Duhamel, Alain [University of Lille (EA 2694), Department of Biostatistics, CHU Lille, Lille (France); Deschildre, Antoine [CHU Lille - University of Lille, Department of Pediatric Pulmonology, Lille (France)

    2017-02-15

    The availability of dual-source technology has introduced the possibility of scanning children at lower kVp with a high-pitch mode, combining high-speed data acquisition and high temporal resolution. To establish the radiation dose levels of dual-source, single-energy chest CT examinations in children. We retrospectively recorded the dose-length product (DLP) of 499 consecutive examinations obtained in children <50 kg, divided into five weight groups: group 1 (<10 kg, n = 129); group 2 (10-20 kg, n = 176); group 3 (20-30 kg, n = 99), group 4 (30-40 kg, n = 58) and group 5 (40-49 kg, n = 37). All CT examinations were performed with high temporal resolution (75 ms), a high-pitch mode and a weight-adapted selection of the milliamperage. CT examinations were obtained at 80 kVp with a milliamperage ranging between 40 mAs and 90 mAs, and a pitch of 2.0 (n = 162; 32.5%) or 3.0 (n = 337; 67.5%). The mean duration of data acquisition was 522.8 ± 192.0 ms (interquartile range 390 to 610; median 490). In the study population, the mean CT dose index volume (CTDIvol{sub 32}) was 0.83 mGy (standard deviation [SD] 0.20 mGy; interquartile range 0.72 to 0.94; median 0.78); the mean DLP{sub 32} was 21.4 mGy.cm (SD 9.1 mGy.cm; interquartile range 15 to 25; median 19.0); and the mean size-specific dose estimate (SSDE) was 1.7 mGy (SD 0.4 mGy; interquartile range 1.5 to 1.9; median 1.7). The DLP{sub 32}, CTDI{sub vol32} and SSDE were found to be statistically significant in the five weight categories (P < 0.0001). This study establishes the radiation dose levels for dual-source, single-kVp chest CT from a single center. In the five weight categories, the median values varied 15-37 mGy.cm for the DLP{sub 32}, 0.78-1.25 mGy for the CTDI{sub vol32} and 1.6-2.1 mGy for the SSDE. (orig.)

  20. Testing of isolation barrier sealing surfaces

    Energy Technology Data Exchange (ETDEWEB)

    Graves, C.E.

    1994-12-15

    Isolation barrier doors are to be installed in the 105KE and 105KW basins as part of the 1994 unreviewed safety question (USQ) resolution plan to isolate the fuel storage basin from the fuel discharge chute. Included in this installation is the placement of new sealing surfaces for the barriers by affixing stainless steel plates to existing carbon steel angle bars with a specially formulated epoxy adhesive/sealant material. The sealant is a two-part component consisting of an epoxy resin (the condensation product of bisphenol A and epichlorohydrin) and a curing agent (a proprietary cycloaliphatic polyamine). The sealant is solvent free (complying with air pollution regulations) and capable of withstanding the surrounding radiation fields over an estimated 15-year service life. The epoxy sealant experiences negligible water damage partly because of its hydrophobic (water-repelling) nature. With bond tensile strengths measured at greater than 862 kPa (125 lbf/in{sup 2}), the epoxy sealant is judged acceptable for its intended application. The four-hour pot life of the epoxy sealant provides sufficient time to apply the epoxy, examine the epoxy bead for continuity, and position the stainless steel sealing plates.

  1. Sources

    OpenAIRE

    2015-01-01

    Sources Fondation Pablo Iglesias. Alcala de Henares. Sections : Archives privées de Manuel ArijaArchives extérieuresArchives FNJS de EspañaPrensa Archives Générales de l’Administration. Alcala de Henares. Sections : Opposition au franquismeSig. 653 Sig TOP 82/68.103-68.602.Índice de las cartas colectivas, Relaciones, Cartas al Ministro de Información de Marzo de 1965. c.662. Sources cinématographiques Filmothèque Nationale d’Espagne.NO.DO. N° 1157C. 08/03/1965.aguirre Javier, Blanco vertical....

  2. Further Investigations of Hypersonic Engine Seals

    Science.gov (United States)

    Dunlap, Patrick H., Jr.; Steinetz, Bruce M.; DeMange, Jeffrey J.

    2004-01-01

    Durable, flexible sliding seals are required in advanced hypersonic engines to seal the perimeters of movable engine ramps for efficient, safe operation in high heat flux environments at temperatures of 2000 to 2500 F. Current seal designs do not meet the demanding requirements for future engines, so NASA's Glenn Research Center is developing advanced seals and preloading devices to overcome these shortfalls. An advanced ceramic wafer seal design and two silicon nitride compression spring designs were evaluated in a series of compression, scrub, and flow tests. Silicon nitride wafer seals survived 2000 in. (50.8 m) of scrubbing at 2000 F against a silicon carbide rub surface with no chips or signs of damage. Flow rates measured for the wafers before and after scrubbing were almost identical and were up to 32 times lower than those recorded for the best braided rope seal flow blockers. Silicon nitride compression springs showed promise conceptually as potential seal preload devices to help maintain seal resiliency.

  3. Harbour seals (Phoca vitulina and rehabilitation

    Directory of Open Access Journals (Sweden)

    Nynke Osinga

    2010-09-01

    Full Text Available Throughout the past few decades, rehabilitation of seals has become an activity that is anchored in the present day society of many countries. Seals are primarily rehabilitated to help individual animals in distress. At the same time, the release of seals which would have otherwise died can be considered as a contribution to the population. Most rehabilitated seals are animals under one year of age. They are mainly orphans, weaned seals with complications and seals with a parasiticbronchopneumonia. For the optimal handling of seals and their diseases, centralised operations with quality standards are essential. Rehabilitation provides an instrument to monitor the health of the seal population and its ecosystem. Changes in stranding trends or the appearance of new diseases can be monitored. Moreover, rehabilitation is important to show the general public thestate of the marine environment. In the Netherlands there is significant social support for the rehabilitation of seals. Experience obtained with seal care is of importance in countries where urgent help of threatened seal species is required. Here individual seals are also ambassadors to raise support for the protection of this species in general. Given that the anthropogenic impact on the seals and their environment is extensive in the Wadden Sea, rehabilitation centres can compensate the consequences of this impact on individual seals as well as the population as a whole.

  4. Dosimetric evaluation of new approaches in GRID therapy using nonconventional radiation sources

    Energy Technology Data Exchange (ETDEWEB)

    Martínez-Rovira, I., E-mail: immamartinez@gmail.com; Prezado, Y. [Laboratoire d’Imagerie et Modélisation en Neurobiologie et Cancérologie (IMNC), Centre National de la Recherche Scientifique (CNRS), Campus universitaire, Bât. 440, 1er étage—15 rue Georges Clemenceau, Orsay cedex 91406 (France); Fois, G. [Dipartimento di Fisica, Università degli Studi di Cagliari, Strada provinciale Monserrato Sestu km 0.700, Monserrato, Cagliari 09042 (Italy)

    2015-02-15

    Purpose: Spatial fractionation of the dose has proven to be a promising approach to increase the tolerance of healthy tissue, which is the main limitation of radiotherapy. A good example of that is GRID therapy, which has been successfully used in the management of large tumors with low toxicity. The aim of this work is to explore new avenues using nonconventional sources: GRID therapy by using kilovoltage (synchrotron) x-rays, the use of very high-energy electrons, and proton GRID therapy. They share in common the use of the smallest possible grid sizes in order to exploit the dose–volume effects. Methods: Monte Carlo simulations (PENELOPE/PENEASY and GEANT4/GATE codes) were used as a method to study dose distributions resulting from irradiations in different configurations of the three proposed techniques. As figure of merit, percentage (peak and valley) depth dose curves, penumbras, and central peak-to-valley dose ratios (PVDR) were evaluated. As shown in previous biological experiments, high PVDR values are requested for healthy tissue sparing. A superior tumor control may benefit from a lower PVDR. Results: High PVDR values were obtained in the healthy tissue for the three cases studied. When low energy photons are used, the treatment of deep-seated tumors can still be performed with submillimetric grid sizes. Superior PVDR values were reached with the other two approaches in the first centimeters along the beam path. The use of protons has the advantage of delivering a uniform dose distribution in the tumor, while healthy tissue benefits from the spatial fractionation of the dose. In the three evaluated techniques, there is a net reduction in penumbra with respect to radiosurgery. Conclusions: The high PVDR values in the healthy tissue and the use of small grid sizes in the three presented approaches might constitute a promising alternative to treat tumors with such spatially fractionated radiotherapy techniques. The dosimetric results presented here

  5. Computed Tomography Angiography with a 192-slice Dual-source Computed Tomography System: Improvements in Image Quality and Radiation Dose

    Directory of Open Access Journals (Sweden)

    Philip V M Linsen

    2016-01-01

    Full Text Available Purpose: This study aims to compare image quality, radiation dose, and the influence of the heart rate on image quality of high-pitch spiral coronary computed tomography angiography (CCTA using 128-slice (second generation dual-source CT (DSCT and a 192-slice DSCT (third generation scanner. Materials and Methods: Two consecutive cohorts of fifty patients underwent CCTA by high-pitch spiral scan mode using 128 or 192-slice DSCT. The 192-slice DSCT system has a more powerful roentgen tube (2 × 120 kW that allows CCTA acquisition at lower tube voltages, wider longitudinal coverage for faster table speed (732 m/s, and the use of iterative reconstruction. Objective image quality was measured as the signal-to-noise ratio (SNR and contrast-to-noise ratio (CNR. Subjective image quality was evaluated using a Likert scale. Results: While the effective dose was lower with 192-slice DSCT (1.2 ± 0.5 vs. 0.6 ± 0.3 mSv; P < 0.001, the SNR (18.9 ± 4.3 vs. 11.0 ± 2.9; P < 0.001 and CNR (23.5 ± 4.8 vs. 14.3 ± 4.1; P < 0.001 were superior to 128-slice DSCT. Although patients scanned with 192-slice DSCT had a faster heart rate (59 ± 7 vs. 56 ± 6; P = 0.045, subjective image quality was scored higher (4.2 ± 0.8 vs. 3.0 ± 0.7; P < 0.001 compared to 128-slice DSCT. Conclusions: High-pitch spiral CCTA by 192-slice DSCT provides better image quality, despite a higher average heart rate, at lower radiation doses compared to 128-slice DSCT.

  6. Turbine interstage seal with self-balancing capability

    Energy Technology Data Exchange (ETDEWEB)

    Mills, Jacob A; Jones, Russell B; Sexton, Thomas D

    2017-09-26

    An interstage seal for a turbine of a gas turbine engine, the interstage seal having a seal carrier with an axial extending seal tooth movable with a stator of the engine, and a rotor with a seal surface that forms the interstage seal with the seal tooth, where a magnetic force produced by two magnets and a gas force produced by a gas pressure acting on the seal carrier forms a balancing force to maintain a close clearance of the seal without the seal tooth contacting the rotor seal surfaces during engine operation. In other embodiments, two pairs of magnets produce first and second magnetic forces that balance the seal in the engine.

  7. Realization of radiobiological in vitro cell experiments at conventional X-ray tubes and unconventional radiation sources

    Energy Technology Data Exchange (ETDEWEB)

    Beyreuther, Elke

    2010-09-10

    More than hundred years after the discovery of X-rays different kinds of ionizing radiation are ubiquitous in medicine, applied to clinical diagnostics and cancer treatment as well. Irrespective of their nature, the widespread application of radiation implies its precise dosimetric characterization and detailed knowledge of the radiobiological effects induced in cancerous and normal tissue. Starting with in vitro cell irradiation experiments, which define basic parameters for the subsequent tissue and animal studies, the whole multi-stage process is completed by clinical trials that translate the results of fundamental research into clinical application. In this context, the present dissertation focuses on the establishment of radiobiological in vitro cell experiments at unconventional, but clinical relevant radiation qualities. In the first part of the present work the energy dependent biological effectiveness of photons was studied examining low-energy X-rays (≤ 50 keV), as used for mammography, and high-energy photons (≥ 20 MeV) as proposed for future radiotherapy. Cell irradiation experiments have been performed at conventional X-ray tubes providing low-energy photons and 200 kV reference radiation as well. In parallel, unconventional quasi-monochromatic channeling X-rays and high-energy bremsstrahlung available at the radiation source ELBE of the Forschungszentrum Dresden-Rossendorf were considered for radiobiological experimentation. For their precise dosimetric characterization dosimeters based on the thermally stimulated emission of exoelectrons and on radiochromic films were evaluated, whereas just the latter was found to be suitable for the determination of absolute doses and spatial dose distributions at cell position. Standard ionization chambers were deployed for the online control of cell irradiation experiments. Radiobiological effects were analyzed in human mammary epithelial cells on different subcellular levels revealing an increasing amount

  8. Influence of the soil sealing on the geoaccumulation index of heavy metals and various pollution factors.

    Science.gov (United States)

    Charzyński, Przemysław; Plak, Andrzej; Hanaka, Agnieszka

    2017-02-01

    Soil sealing belongs to the most destructive and damaging processes to the soil environment. Soil sealing interrupts or greatly restricts the exchange of matter and energy between the biosphere, hydrosphere, and atmosphere and the soil environment. The aim of this study was to compare the content of heavy metals (Cd, Cr, Cu, Hg, Fe, Ni, Pb, Zn) of Ekranic Technosols by applying indicators such as geoaccumulation index (I geo), enrichment factor (EF), and pollution load index (PLI), which allowed to determine quantitatively the impact of the soil sealing degree on the content of heavy metals and to distinguish natural from anthropogenic sources of origin of heavy metals. In general, 42 soils from different parts of the city of Toruń (NW Poland) were sampled and divided into three groups according to the degree of soil sealing: completely sealed with asphalt or concrete (A), semi-permeable (partially sealed with cobblestones and concrete paving slabs (B)), and reference (non-sealed) (C). The results indicate that the artificial sealing in urban areas slightly affects the content of heavy metals in soils. However, based on PLI, I geo, and EF, it was found that the sealing has influence on soil properties and unsealed soil is the most exposed to the accumulation of pollutants.

  9. Gas Path Sealing in Turbine Engines

    Science.gov (United States)

    Ludwig, L. P.

    1978-01-01

    A survey of gas path seals is presented with particular attention given to sealing clearance effects on engine component efficiency. The effects on compressor pressure ratio and stall margin are pointed out. Various case-rotor relative displacements, which affect gas path seal clearances, are identified. Forces produced by nonuniform sealing clearances and their effect on rotor stability are discussed qualitatively, and recent work on turbine-blade-tip sealing for high temperature is described. The need for active clearance control and for engine structural analysis is discussed. The functions of the internal-flow system and its seals are reviewed.

  10. Rapid infrared laser sealing and cutting of porcine renal vessels, ex vivo

    Science.gov (United States)

    Giglio, Nicholas C.; Hutchens, Thomas C.; Perkins, William C.; Latimer, Cassandra; Ward, Arlen; Nau, William H.; Fried, Nathaniel M.

    2014-03-01

    Suture ligation with subsequent cutting of blood vessels to maintain hemostasis during surgery is time consuming and skill intensive. Energy-based, electrosurgical and ultrasonic devices are often used to replace sutures and mechanical clips to provide rapid hemostasis, and decrease surgical time. Some of these devices may create undesirably large collateral zones of thermal damage and tissue necrosis, or require separate mechanical blades for cutting. Infrared lasers are currently being explored as alternative energy sources for vessel sealing applications. In a previous study, a 1470-nm laser was used to seal vessels of 1-6 mm in diameter in 5 s, yielding burst pressures of ~ 500 mmHg. The purpose of this study was to provide faster sealing, incorporate transection of the sealed vessels, and increase the burst pressure. A 110-Watt, 1470-nm laser beam was transmitted through a fiber and beam shaping optics, producing a linear beam 3.0 mm by 9.5 mm for sealing, and 1.1 mm by 9.6 mm for cutting (FWHM). A twostep process sealed then transected ex vivo porcine renal vessels (1-8.5 mm diameter) in a bench top setup. Seal and cut times were 1.0 s each. A standard burst pressure system measured resulting seal strength, and gross and histologic thermal damage measurements were also recorded. All blood vessels tested (n = 30) were sealed and cut, with total irradiation times of 2.0 s, mean burst pressures > 1000 mmHg (compared to normal systolic blood pressure of 120 mmHg), and combined seal/collateral thermal coagulation zones of 2-3 mm. The results of this study demonstrated that an optical-based system is capable of precisely sealing and cutting a wide range of porcine renal vessel sizes, and with further development, may provide an alternative to radiofrequency and ultrasound-based vessel sealing devices.

  11. Cryogenic Flange and Seal Evaluation

    Science.gov (United States)

    Ramirez, Adrian

    2014-01-01

    The assembly of flanges, seals, and pipes are used to carry cryogenic fluid from a storage tank to the vehicle at launch sites. However, after a certain amount of cycles these raised face flanges with glass-filled Teflon gaskets have been found to have torque relaxation and are as a result susceptible to cryogenic fluid leakage if not re-torqued. The intent of this project is to identify alternate combinations of flanges and seals which may improve thermal cycle performance and decrease re-torque requirements. The general approach is to design a test fixture to evaluate leak characteristics between spiral and concentric serrations and to test alternate flange and seal combinations. Due to insufficient time, it was not possible to evaluate these different types of combinations for the combination that improved thermal cycle performance the most. However, the necessary drawings for the test fixture were designed and assembled along with the collection of the necessary parts.

  12. Mechanical seal with textured sidewall

    Science.gov (United States)

    Khonsari, Michael M.; Xiao, Nian

    2017-02-14

    The present invention discloses a mating ring, a primary ring, and associated mechanical seal having superior heat transfer and wear characteristics. According to an exemplary embodiment of the present invention, one or more dimples are formed onto the cylindrical outer surface of a mating ring sidewall and/or a primary ring sidewall. A stationary mating ring for a mechanical seal assembly is disclosed. Such a mating ring comprises an annular body having a central axis and a sealing face, wherein a plurality of dimples are formed into the outer circumferential surface of the annular body such that the exposed circumferential surface area of the annular body is increased. The texture added to the sidewall of the mating ring yields superior heat transfer and wear characteristics.

  13. Electromagnetic fields E.D. 4202. The non ionizing radiations sources (till 60 GHz); Champs electromagnetiques ED 4202. Les sources de rayonnements non ionisants (jusqu'a 60 GHz)

    Energy Technology Data Exchange (ETDEWEB)

    Bisseriex, Ch. [Cram Auvergne, 63 - Clermont-Ferrand (France); Laurent, P. [Cram Centre-Ouest, 87 - Limoges (France); Cabaret, Ph. [CRAM Languedoc-Roussillon, 34 - Montpellier (France); Renard, Ch. [Cram Centre, 45 - Orleans (France); Marteau, E.; Masson, Ch. [CRAM Ile-de-France, 75 - Paris (France); Le Berre, G. [Cram de Bretagne, 35 - Rennes (France); Becker, A.; Demaret, Ph.; Herrault, J.; Donati, P.; Bouillot, C. [INRS - Centre de Lorraine, 54 - Vandoeuvre (France); Servent, J.P.; Ganem, Y. [Institut National de Recherche et de Securite (INRS), 75 - Paris (France)

    2004-11-15

    The sources of electromagnetic fields or non ionizing radiations are common in industry. This card gives a most exhaustive as possible spotting of the principal working applications using frequencies between 0 to 60 GHz, that could involve effects on man. (N.C.)

  14. A survey of the optical hazards associated with hospital light sources with reference to the Control of Artificial Optical Radiation at Work Regulations 2010.

    Science.gov (United States)

    Coleman, A; Fedele, F; Khazova, M; Freeman, P; Sarkany, R

    2010-09-01

    Workplace exposure to coherent and incoherent optical radiation from artificial sources is regulated under the Artificial Optical Radiation Directive (AORD) 2006/25/EC, now implemented in the UK under the Control of Artificial Optical Radiation at Work Regulations (AOR) 2010. These regulations set out exposure limit values. Implementing the AOR (2010 Health and Safety Statutory Instrument No 1140 www.legislation.gov.uk/uksi/2010/1140/pdf/uksi_20101140_en.pdf) requirements in a hospital environment is a potentially complex problem because of the wide variety of sources used for illumination, diagnosis and therapy. A survey of sources of incoherent optical radiation in a large hospital is reported here. The survey covers examples of office lighting, operating theatre lighting, examination lamps, and sources for ultraviolet phototherapy and visible phototherapies, including photodynamic therapy and neonatal blue-light therapy. The results of the survey are used to inform consideration of the strategy that a hospital might reasonably adopt both to demonstrate compliance with the AOR (2010) and to direct implementation effort.

  15. A survey of the optical hazards associated with hospital light sources with reference to the Control of Artificial Optical Radiation at Work Regulations 2010

    Energy Technology Data Exchange (ETDEWEB)

    Coleman, A; Fedele, F; Freeman, P [Medical Physics Department, Guy' s and St Thomas' NHS Foundation Trust, Westminster Bridge Road, London SE1 7EH (United Kingdom); Khazova, M [Health Protection Agency, Centre for Radiation, Chemical and Environmental Hazards, Radiation Protection Division, Chilton, Didcot, Oxfordshire OX11 ORQ (United Kingdom); Sarkany, R, E-mail: andrew.coleman@gstt.nhs.u [St John' s Institute of Dermatology, Guy' s and St Thomas' NHS Foundation Trust, Westminster Bridge Road, London SE1 7EH (United Kingdom)

    2010-09-15

    Workplace exposure to coherent and incoherent optical radiation from artificial sources is regulated under the Artificial Optical Radiation Directive (AORD) 2006/25/EC, now implemented in the UK under the Control of Artificial Optical Radiation at Work Regulations (AOR) 2010. These regulations set out exposure limit values. Implementing the AOR (2010 Health and Safety Statutory Instrument No 1140 www.legislation.gov.uk/uksi/2010/1140/pdf/uksi{sub 2}0101140{sub e}n.pdf) requirements in a hospital environment is a potentially complex problem because of the wide variety of sources used for illumination, diagnosis and therapy. A survey of sources of incoherent optical radiation in a large hospital is reported here. The survey covers examples of office lighting, operating theatre lighting, examination lamps, and sources for ultraviolet phototherapy and visible phototherapies, including photodynamic therapy and neonatal blue-light therapy. The results of the survey are used to inform consideration of the strategy that a hospital might reasonably adopt both to demonstrate compliance with the AOR (2010) and to direct implementation effort.

  16. Grey seal induced catch losses in the herring gillnet fisheries in the northern Baltic

    Directory of Open Access Journals (Sweden)

    Sara Königson

    2007-01-01

    Full Text Available The interaction between grey seals (Halichoerus grypus and the Baltic gillnet fishery for herring (Clupea harengus during the period 2000-2005 was investigated, by comparing and contrasting 3 sources of information: data from the European Union (EU official logbook system, data from a voluntary logbook system and data from field studies. While the EU official logbooks suggest that seal disturbance occurred in 30% of all herring gillnet fishing events, data from the voluntary logbook gavea figure of 60%. There was a pronounced seasonal variation in the frequency of seal-disturbed fishing efforts, with least interference in the early summer, and greatest at the end of the year. This variation is likely dependent on the life cycle of the seals and their main prey, the herring. Analysis of the EU logbook information also showed that catches were significantly higher on fishing days when there was no seal interference recorded, compared to days when there was such interference. Field experiments demonstrated that herring catches were reduced by 240 kg per fleet of net and fishing occasion when seals were present, which is much more than the observed seals in the area could possibly have consumed, and a very small number of fish remains were found in the nets after seals had been present. These observations suggest that the mere presence of seals does affect catch levels negatively. Nets baited with marked fish were used to estimate hidden losses, i.e. fish removed from the nets, leaving no trace. Seals were assumed to have visited the experimental nets in 14 of the 19 trials. In 11 of these, more than 95% of the marked fish went missing. The 3 different data sources altogether show that the herring gillnet fishery in the northern Baltic is severely disturbed by interaction with grey seals.

  17. A Dataset of Aerial Survey Counts of Harbor Seals in Iliamna Lake, Alaska: 1984-2013

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — This dataset provides counts of harbor seals from aerial surveys over Iliamna Lake, Alaska, USA. The data have been collated from three previously published sources...

  18. Aerial Survey Counts of Harbor Seals in Lake Iliamna, Alaska, 1984-2013 (NODC Accession 0123188)

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — This dataset provides counts of harbor seals from aerial surveys over Lake Iliamna, Alaska, USA. The data have been collated from three previously published sources...

  19. Harbor seals (Phoca vitulina can perceive optic flow under water.

    Directory of Open Access Journals (Sweden)

    Nele Gläser

    Full Text Available Optic flow, the pattern of apparent motion elicited on the retina during movement, has been demonstrated to be widely used by animals living in the aerial habitat, whereas underwater optic flow has not been intensively studied so far. However optic flow would also provide aquatic animals with valuable information about their own movement relative to the environment; even under conditions in which vision is generally thought to be drastically impaired, e. g. in turbid waters. Here, we tested underwater optic flow perception for the first time in a semi-aquatic mammal, the harbor seal, by simulating a forward movement on a straight path through a cloud of dots on an underwater projection. The translatory motion pattern expanded radially out of a singular point along the direction of heading, the focus of expansion. We assessed the seal's accuracy in determining the simulated heading in a task, in which the seal had to judge whether a cross superimposed on the flow field was deviating from or congruent with the actual focus of expansion. The seal perceived optic flow and determined deviations from the simulated heading with a threshold of 0.6 deg of visual angle. Optic flow is thus a source of information seals, fish and most likely aquatic species in general may rely on for e. g. controlling locomotion and orientation under water. This leads to the notion that optic flow seems to be a tool universally used by any moving organism possessing eyes.

  20. Particle Radiation Sources, Propagation and Interactions in Deep Space, at Earth, the Moon, Mars, and Beyond: Examples of Radiation Interactions and Effects

    Science.gov (United States)

    Schwadron, Nathan A.; Cooper, John F.; Desai, Mihir; Downs, Cooper; Gorby, Matt; Jordan, Andrew P.; Joyce, Colin J.; Kozarev, Kamen; Linker, Jon A.; Mikíc, Zoran; Riley, Pete; Spence, Harlan E.; Török, Tibor; Townsend, Lawrence W.; Wilson, Jody K.; Zeitlin, Cary

    2017-07-01

    Particle radiation has significant effects for astronauts, satellites and planetary bodies throughout the Solar System. Acute space radiation hazards pose risks to human and robotic exploration. This radiation also naturally weathers the exposed surface regolith of the Moon, the two moons of Mars, and other airless bodies, and contributes to chemical evolution of planetary atmospheres at Earth, Mars, Venus, Titan, and Pluto. We provide a select review of recent areas of research covering the origin of SEPs from coronal mass ejections low in the corona, propagation of events through the solar system during the anomalously weak solar cycle 24 and important examples of radiation interactions for Earth, other planets and airless bodies such as the Moon.

  1. Particle Radiation Sources, Propagation and Interactions in Deep Space, at Earth, the Moon, Mars, and Beyond: Examples of Radiation Interactions and Effects

    Science.gov (United States)

    Schwadron, Nathan A.; Cooper, John F.; Desai, Mihir; Downs, Cooper; Gorby, Matt; Jordan, Andrew P.; Joyce, Colin J.; Kozarev, Kamen; Linker, Jon A.; Mikíc, Zoran; Riley, Pete; Spence, Harlan E.; Török, Tibor; Townsend, Lawrence W.; Wilson, Jody K.; Zeitlin, Cary

    2017-11-01

    Particle radiation has significant effects for astronauts, satellites and planetary bodies throughout the Solar System. Acute space radiation hazards pose risks to human and robotic exploration. This radiation also naturally weathers the exposed surface regolith of the Moon, the two moons of Mars, and other airless bodies, and contributes to chemical evolution of planetary atmospheres at Earth, Mars, Venus, Titan, and Pluto. We provide a select review of recent areas of research covering the origin of SEPs from coronal mass ejections low in the corona, propagation of events through the solar system during the anomalously weak solar cycle 24 and important examples of radiation interactions for Earth, other planets and airless bodies such as the Moon.

  2. Stabilizing geometry for hydrodynamic rotary seals

    Science.gov (United States)

    Dietle, Lannie L.; Schroeder, John E.

    2010-08-10

    A hydrodynamic sealing assembly including a first component having first and second walls and a peripheral wall defining a seal groove, a second component having a rotatable surface relative to said first component, and a hydrodynamic seal comprising a seal body of generally ring-shaped configuration having a circumference. The seal body includes hydrodynamic and static sealing lips each having a cross-sectional area that substantially vary in time with each other about the circumference. In an uninstalled condition, the seal body has a length defined between first and second seal body ends which varies in time with the hydrodynamic sealing lip cross-sectional area. The first and second ends generally face the first and second walls, respectively. In the uninstalled condition, the first end is angulated relative to the first wall and the second end is angulated relative to the second wall. The seal body has a twist-limiting surface adjacent the static sealing lip. In the uninstalled condition, the twist-limiting surface is angulated relative to the peripheral wall and varies along the circumference. A seal body discontinuity and a first component discontinuity mate to prevent rotation of the seal body relative to the first component.

  3. Self-Sealing Cryogenic Fitting

    Science.gov (United States)

    Jia, Lin Xiang; Chow, Wen Lung; Moslemian, Davood; Lin, Gary; Melton, Greg

    1994-01-01

    Self-sealing fitting for cryogenic tubes remains free of leakage from room temperature to liquid-helium temperature even at internal pressure as high as 2.7 MPa. Fitting comprises parts made of materials with different coefficients of thermal expansion to prevent leakage gaps from forming as temperature decreases. Consists of coupling nut, two flared tube ends, and flared O-ring spacer. Spacer contracts more than tube ends do as temperature decreases. This greater contraction seals tube ends more tightly, preventing leakage.

  4. Generation of auroral kilometric radiation by a finite-size source in a dipole magnetic field. Part II

    Science.gov (United States)

    Burinskaya, T. M.; Shevelev, M. M.

    2017-09-01

    Propagation and amplification of extraordinary electromagnetic waves in a dipole magnetic field in a narrow 3D plasma cavity in which a weakly relativistic electron beam propagates along the magnetic field in the direction of the gradient of the magnetic field strength is investigated. The domain of wave vectors at the starting point for which the wave amplification factors at the output of the density cavity reach their maximum values is found, and the amplification factor as a function of the wave frequency is determined. It is shown that the longitudinal velocity of fast electrons, which enables generation of waves in a broader frequency range, plays an important role in the formation of the spectrum of the auroral kilometric radiation (AKR). In this case, waves with the largest amplification factors at the output of the cavity have frequencies exceeding the cutoff frequency of the background plasma at the wave generation altitude. The global inhomogeneity of the magnetic field and plasma density, which governs the residence time of the waves in the amplification region, plays a key role in the formation of the AKR spectrum. It is shown that this time is the main factor determining the energy of the waves emerging from the source.

  5. Imaging of the elbow in children with wrist fracture: an unnecessary source of radiation and use of resources?

    Energy Technology Data Exchange (ETDEWEB)

    Golding, Lauren P. [Wake Forest University Baptist Health, Department of Radiology, Winston-Salem, NC (United States); Triad Radiology Associates, Winston-Salem, NC (United States); Yasin, Yousef; Singh, Jasmeet; Anthony, Evelyn [Wake Forest University Baptist Health, Department of Radiology, Winston-Salem, NC (United States); Gyr, Bettina M. [Wake Forest University Baptist Health, Department of Orthopedic Surgery, Winston-Salem, NC (United States); Gardner, Alison [Wake Forest University Baptist Health, Department of Pediatric Emergency Medicine, Winston-Salem, NC (United States)

    2015-08-15

    Anecdotally accepted practice for evaluation of children with clinically suspected or radiographically proven wrist fracture in many urgent care and primary care settings is concurrent imaging of the forearm and elbow, despite the lack of evidence to support additional images. These additional radiographs may be an unnecessary source of radiation and use of health care resources. Our study assesses the necessity of additional radiographs of the forearm and elbow in children with wrist injury. We reviewed electronic medical records of children 17 and younger in whom wrist fracture was diagnosed in the emergency department. We identified the frequency with which additional radiographs of the proximal forearm and distal humerus demonstrated another site of acute injury. We identified 214 children with wrist fracture. Of those, 129 received additional radiographs of the elbow. Physical examination findings proximal to the wrist were documented in only 16 (12%) of these 129 children. A second injury proximal to the wrist fracture was present in 4 (3%) of these 129 children, all of whom exhibited physical examination findings at the elbow. No fractures were documented in children with a negative physical examination of the elbow. Although elbow fractures occasionally complicate distal forearm fractures in children, our findings indicate that a careful physical evaluation of the elbow is sufficient to guide further radiographic investigation. Routine radiographs of both the wrist and elbow in children with distal forearm fracture appear to be unnecessary when an appropriate physical examination is performed. (orig.)

  6. DMS atmospheric concentrations and sulphate aerosol indirect radiative forcing: a sensitivity study to the DMS source representation and oxidation

    Directory of Open Access Journals (Sweden)

    O. Boucher

    2003-01-01

    Full Text Available The global sulphur cycle has been simulated using a general circulation model with a focus on the source and oxidation of atmospheric dimethylsulphide (DMS. The sensitivity of atmospheric DMS to the oceanic DMS climatology, the parameterisation of the sea-air transfer and to the oxidant fields have been studied. The importance of additional oxidation pathways (by O3 in the gas- and aqueous-phases and by BrO in the gas phase not incorporated in global models has also been evaluated. While three different climatologies of the oceanic DMS concentration produce rather similar global DMS fluxes to the atmosphere at 24-27 Tg S yr -1, there are large differences in the spatial and seasonal distribution. The relative contributions of OH and NO3 radicals to DMS oxidation depends critically on which oxidant fields are prescribed in the model. Oxidation by O3 appears to be significant at high latitudes in both hemispheres. Oxidation by BrO could be significant even for BrO concentrations at sub-pptv levels in the marine boundary layer. The impact of such refinements on the DMS chemistry onto the indirect radiative forcing by anthropogenic sulphate aerosols is also discussed.

  7. A new time and space resolved transmission spectrometer for research in inertial confinement fusion and radiation source development.

    Science.gov (United States)

    Knapp, P F; Ball, C; Austin, K; Hansen, S B; Kernaghan, M D; Lake, P W; Ampleford, D J; McPherson, L A; Sandoval, D; Gard, P; Wu, M; Bourdon, C; Rochau, G A; McBride, R D; Sinars, D B

    2017-01-01

    We describe the design and function of a new time and space resolved x-ray spectrometer for use in Z-pinch inertial confinement fusion and radiation source development experiments. The spectrometer is designed to measure x-rays in the range of 0.5-1.5 Å (8-25 keV) with a spectral resolution λ/Δλ ∼ 400. The purpose of this spectrometer is to measure the time- and one-dimensional space-dependent electron temperature and density during stagnation. These relatively high photon energies are required to escape the dense plasma created at stagnation and to obtain sensitivity to electron temperatures ≳3 keV. The spectrometer is of the Cauchois type, employing a large 30 × 36 mm(2), transmissive quartz optic for which a novel solid beryllium holder was designed. The performance of the crystal was verified using offline tests, and the integrated system was tested using experiments on the Z pulsed power accelerator.

  8. A survey of sources of incoherent artificial optical radiation in a hospital environment in accordance with European Directive 2006/25/EC: evaluation of the related exposure risk.

    Science.gov (United States)

    Cavatorta, Claudia; Lualdi, Manuela; Meroni, Silvia; Polita, Giovanni; Bolchi, Mauro; Pignoli, Emanuele

    2016-03-01

    The evaluation of incoherent artificial optical radiation (AOR) exposure in hospital environments is a complex task due to the variety of sources available. This study has been designed to provide a proposal for the precautionary assessment of the related risk. This survey suggested that, in our Institution, at least three kinds of AOR sources required specific investigations: ambient lighting, theatre operating lighting and ultraviolet radiation (UVR) sources. For each kind of evaluated sources a specific measurement approach was developed. All irradiance measurements were made using a commercial spectroradiometer. The obtained results were compared with the appropriate exposure limit values (ELVs) defined in the International Commission on Non-Ionizing Radiation Protection (ICNIRP) guidelines and adopted by the European Directive 2006/25/EC. The risk related to the evaluated AOR exposure was finally assessed according to our risk matrix. According to our results, the emission of ambient lighting in the actual exposure conditions was always in accordance with the ELVs and the related risk was classifiable as not relevant. The risk related to the exposure to theatre operating lighting resulted not negligible, especially when two or more sources were used with focal spots overlapping on reflective objects. UVR sources emission may represent a health hazard depending, in particular, on the set up of the device containing the source. In case of laminar flow cabinets and closed transilluminators, if the UVR source is well contained within an enclosure with interlock, it presents no risk of exposure. Otherwise, the emission arising from UVR lamps, open transilluminators or sources not provided with interlock, may represent a risk classifiable as high even in the actual working conditions. The personal protective equipment used by workers were also assessed and their suitability was discussed.

  9. POP load and vitamins as potential biomarkers in the Baltic seals

    Energy Technology Data Exchange (ETDEWEB)

    Routti, H.; Nyman, M.; Helle, E. [Finnish Game and Fisheries Research Inst., Helsinki (Finland); Backman, C. [National Veterinary and Food Research Inst. (Finland); Koistinen, J. [Div. of Environmental Health, National Public Health Inst. (Finland)

    2004-09-15

    Exceptionally high levels of polychlorinated biphenyls (PCB) and 1,1,1.trichloro- 2,2-bis[p-chlorophenyl]ethane (DDT) and its metabolites were reported in the Baltic seals in the late 1960s and early 1970s. PCB levels in ringed seals, in particular, are still high enough to threaten the well being of the animals. The observed difference in contaminant pattern between ringed and grey seals in the Baltic has not been explained, but could be partly due to species-specific food sources. Several pathological and biochemical changes observed in the Baltic seals correlate with the individual POP loads. Of the observed biochemical changes, elevated cytochrome P4501A (CYP1A) levels, decreased liver vitamin A stores and increased vitamin E levels in blubber or plasma, have been proposed as possible biomarkers of contaminant load in Baltic seals. However, as the vitamin A and E status of marine mammals also reflects the nutritional vitamin level, the lower vitamin A and elevated vitamin E levels observed in the Baltic seals could be a reflection of the levels of these vitamins in their food sources. The aim of this study was to investigate the contaminant load in the Baltic seals and to evaluate the utility level of potential exposure and effect biomarkers. Seals from less contaminated areas were used as reference material (Svalbard and Sable Island, Canada). In the present study, POP and vitamin levels were also studied in seal prey species in order to study the transfer of these compounds to grey and ringed seals from their main food sources.

  10. HMSRP Hawaiian Monk Seal Telemetry Tag Deployments

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — This project investigates foraging behavior of Hawaiian monk seals by conducting telemetry studies. During these studies, live seals are instrumented with dive...

  11. HMSRP Hawaiian Monk Seal Argos Location Data

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — This project investigates foraging behavior of Hawaiian monk seals by conducting telemetry studies. During these studies, live seals are instrumented with satellite...

  12. Seal Apparatus and Methods to Manufacture Thereof

    Science.gov (United States)

    Richard, James A. (Inventor)

    2013-01-01

    In some implementations, apparatus and methods are provided through which a dynamic cryogenic seal is manufactured. In some implementations, the seal includes a retainer and a spring-seal assembly, the assembly being comprised of a main spring housing and fluorine-containing polymer seals. In some implementations, either a radial seal, or an axial (or "piston seal") is provided. In some implementations, methods of manufacturing the dynamic cryogenic seal are also provided. In some implementations, the methods include assembling the components while either heated or cooled, taking advantage of thermal expansion and contraction, such that there is a strong interference fit between the components at room temperature. In some implementations, this process ensures that the weaker fluorine-containing polymer seal is forced to expand and contract with the stronger retainer and spring and is under constant preload. In some implementations, the fluorine-containing polymer is therefore fluidized and retained, and can not lift off.

  13. HMSRP Hawaiian Monk Seal Handling Data

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — This data set contains records for all handling and measurement of Hawaiian monk seals since 1981. Live seals are handled and measured during a variety of events...

  14. HMSRP Hawaiian Monk Seal Crittercam video

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — This project investigates foraging behavior of Hawaiian monk seals by conducting telemetry studies. During these studies, live seals are instrumented with dive...

  15. 7 CFR 330.110 - Seals.

    Science.gov (United States)

    2010-01-01

    ... OF AGRICULTURE FEDERAL PLANT PEST REGULATIONS; GENERAL; PLANT PESTS; SOIL, STONE, AND QUARRY PRODUCTS... inspector. (c) Notice of sealing. When an inspector seals any opening, product or article, he shall explain...

  16. Legacy HMSRP Hawaiian Monk Seal Ultrasound Data

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Ultrasounds measuring the condition of juvenile seals at Laysan Island during 2009-2010, collected when seals were handled as part of the De-Worming Project

  17. Film riding seals for rotary machines

    Science.gov (United States)

    Bidkar, Rahul Anil; Sarawate, Neelesh Nandkumar; Wolfe, Christopher Edward; Ruggiero, Eric John; Raj Mohan, Vivek Raja

    2017-03-07

    A seal assembly for a rotary machine is provided. The seal assembly includes multiple sealing device segments disposed circumferentially intermediate to a stationary housing and a rotor. Each of the segments includes a shoe plate with a forward-shoe section and an aft-shoe section having one or more labyrinth teeth therebetween facing the rotor. The sealing device includes a stator interface element having a groove or slot for allowing disposal of a spline seal for preventing segment leakages. The sealing device segment also includes multiple bellow springs or flexures connected to the shoe plate and to the stator interface element. Further, the sealing device segments include a secondary seal integrated with the stator interface element at one end and positioned about the multiple bellow springs or flexures and the shoe plate at the other end.

  18. Legacy HMSRP Hawaiian Monk Seals Observers

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — This data set documents observers that have collected monk seal data as part of the ongoing monk seal population assessment efforts by PSD personnel and cooperating...

  19. HMSRP Hawaiian Monk Seal Entanglement data

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — The data set contains records of all entanglements of Hawaiian monk seals in marine debris. The data set comprises records of seals entangled by derelict fishing...

  20. Sources

    OpenAIRE

    2014-01-01

    Archives Archivo Histórico del Estado de Jalisco Fondo Gobernación, Asunto Pasaportes y Salvoconductos : G-8-877/9773-9775 G-8-878/9774, 9776, 9777 et 9781 G-8-879/9782-9788 G-8-880/9789-9798 G-8-881-882/9803 G-8-882/9804-9805 G-8-883/9806-9811 G-8-884/9813 G-8-885/9817-9820 G-8-886/9822-9825 G-8-887/9826-9830 G-8-888/9835 G-8-889-890/9837 G-8-889/9839 Sources imprimées Livres et chroniques O’Farrill Romulo, (2004) Reseña histórica estadística y comercial de México y sus estados, directorio g...