WorldWideScience

Sample records for sealants

  1. Dental sealants

    Science.gov (United States)

    ... this page: //medlineplus.gov/ency/patientinstructions/000779.htm Dental sealants To use the sharing features on this ... case a sealant needs to be replaced. How Dental Sealants are Applied Your dentist applies sealants on ...

  2. Dental Sealants Prevent Cavities

    Science.gov (United States)

    ... Digital Press Kit Read the MMWR Science Clips Dental Sealants Prevent Cavities Effective protection for children Language: ... more use of sealants and reimbursement of services. Dental care providers can Apply sealants to children at ...

  3. The state-of-the-art of ART sealants.

    Science.gov (United States)

    Frencken, Jo E

    2014-03-01

    Sealing caries-prone pits and fissure systems is an effective caries-preventive measure. There are basically two types of sealant materials: glass-ionomer and resin-based materials. Low- and medium-viscosity glass-ionomers were initially used and showed a low level of retention. With the advent of the ART approach in the mid-nineties, high-viscosity glass-ionomers were introduced as sealant material and the retention rate of ART sealants increased substantially. As the effectiveness of a sealant is measured by its capacity to prevent (dentine) carious lesion development, sealant retention is considered a surrogate endpoint. The ART sealant protocol is described. Systematic reviews and meta-analysis covering low- medium- and high-viscosity glass-ionomer (ART) sealants have concluded that there is no evidence that either glass-ionomer or resin-based sealants prevent dentine carious lesions better. The annual dentine carious lesion development in teeth with high-viscosity glass-ionomer ART sealants over the first three years is 1%. These ART sealants have a high capacity of preventing carious lesion development. Because no electricity and running water is required, ART sealants can be placed both inside and outside the dental surgery. High-viscosity glass-ionomer ART sealants can be used alongside resin-based sealants.41:119-124

  4. Comparative study of resin sealant and resin modified glass ionomer as pit and fissure sealant

    Directory of Open Access Journals (Sweden)

    Shirin Malek

    2017-02-01

    Full Text Available The purpose of the present study was to compare the marginal integrity of resin modified glass ionomer cement with that of resin sealant, in vitro. Forty artificial pit and fissure cavities were prepared in occlusal surface of extracted premolar teeth by using ¼ round carbide bur. Cavities were condensed with artificial organic debris followed by cleaning with prophylaxis pumice brush and paste and then separated into two treatment groups. In Group A, 15 fissure cavities were sealed by resin sealant and in Group B, 15 fissure cavities were sealed by resin modified glass ionomer sealant. These specimens were subjected to thermo-cycling followed by dye penetration test. The remaining 5 cavities from each group were analyzed for debris score by the SEM. The results of the microleakage test showed that the efficacy of preventing microleakage of samples sealed by resin modified glass ionomer sealant was higher than the samples sealed by resin sealant. However, no significant differences were found. It can be concluded that use of resin modified glass ionomer sealant is a good alternative for sealing pits and fissures.

  5. Parametric Study of Sealant Nozzle

    Science.gov (United States)

    Yamamoto, Yoshimi

    It has become apparent in recent years the advancement of manufacturing processes in the aerospace industry. Sealant nozzles are a critical device in the use of fuel tank applications for optimal bonds and for ground service support and repair. Sealants has always been a challenging area for optimizing and understanding the flow patterns. A parametric study was conducted to better understand geometric effects of sealant flow and to determine whether the sealant rheology can be numerically modeled. The Star-CCM+ software was used to successfully develop the parametric model, material model, physics continua, and simulate the fluid flow for the sealant nozzle. The simulation results of Semco sealant nozzles showed the geometric effects of fluid flow patterns and the influences from conical area reduction, tip length, inlet diameter, and tip angle parameters. A smaller outlet diameter induced maximum outlet velocity at the exit, and contributed to a high pressure drop. The conical area reduction, tip angle and inlet diameter contributed most to viscosity variation phenomenon. Developing and simulating 2 different flow models (Segregated Flow and Viscous Flow) proved that both can be used to obtain comparable velocity and pressure drop results, however; differences are seen visually in the non-uniformity of the velocity and viscosity fields for the Viscous Flow Model (VFM). A comprehensive simulation setup for sealant nozzles was developed so other analysts can utilize the data.

  6. Retention of a resin-based sealant and a glass ionomer used as a fissure sealant: A comparative clinical study

    Directory of Open Access Journals (Sweden)

    Subramaniam P

    2008-09-01

    Full Text Available Sealing occlusal pits and fissures with resin-based sealants is a proven method of preventing occlusal caries. Retention of the sealant is very essential for its efficiency. This study evaluated the retention of glass ionomer used as a fissure sealant when compared to a self-cure resin-based sealant. One hundred and seven children between the ages of 6-9 years, with all four newly erupted permanent first molars were selected. Two permanent first molars on one side of the mouth were sealed with Delton, a resin-based sealant, and the contralateral two permanent first molars were sealed with Fuji VII glass ionomer cement. Evaluation of sealant retention was performed at regular intervals over 12 months, using Simonsen′s criteria. At the end of the study period, the retention of the resin sealant was seen to be superior to that of the glass ionomer sealant.

  7. Moisture-tolerant resin-based sealant: A boon

    Directory of Open Access Journals (Sweden)

    Prasanna Kumar Bhat

    2013-01-01

    Full Text Available Background and Objectives: Pit and fissure sealants are highly effective in preventing occlusal caries. The present study clinically evaluated and compared the retention and development of caries when sealed with moisture-tolerant resin-based sealant, conventional resin-based sealant with and without a bonding agent, and Glass Ionomer Cement Sealant in young permanent teeth. Materials and Methods: A total of 80 healthy cooperative children aged 6-9 years who were at high caries risk with all four newly erupted permanent first molars were included in the study. Teeth were divided into 4 groups using a full-factorial design, and each of the molars was sealed with the four different sealant material. Evaluation of sealant retention and development of caries was performed at 6 and 12 months using Modified Simonsen′s criteria. The data obtained were tabulated and subjected to statistical analysis using Kruskal-Wallis Test and Mann-Whitney Test. Result and Conclusion: The result from the present study indicated that moisture-tolerant resin-based sealant could be successfully used as a pit and fissure sealant because its hydrophilic chemistry makes it less technique sensitive and simplifies the sealant application procedure.

  8. Use of sealants: societal and professional factors.

    Science.gov (United States)

    Frazier, P J

    1984-02-01

    At present, sealant use continues at a low level in private practice by dentists and hygienists, and is moderate in community programs although there is high interest in their use in public health settings. Widespread delegation of sealant application to hygienists has not occurred even though the majority of state dental practice acts allow it, and even though practicing hygienists are highly interested in applying sealants. Use in federally sponsored programs is minimal or nonexistent. Information about sealants and adequate clinical experience in their application appear minimal in dental training institutions, and few opportunities have existed for continuing education. Generally, knowledge about sealants among dentists is low; many hold doubtful opinions. Insurance carriers, including commercial, provider, and governmental programs, appear reluctant to reimburse for sealants without purchaser demand and organized dentistry's blessings. Although society emphasizes patient rights to informed consent, few opportunities exist for the public, including group insurance purchasers and union negotiators, to learn about sealant use in conjunction with appropriate fluoride use. Public educational materials are sparse. Manufacturer marketing efforts at present, aimed at providers alone, are at best minimal, with a few exceptions; those targeting the public are nonexistent. Organized dentistry's Council statements may have contributed to a constriction, to date, in the flow of public information about sealants from industry. Lack of communication, or miscommunication, between practitioners and dental scientists has resulted in much misinformation and confusion about the value of sealants and their use. And, the contemporary status of dental manpower and the economy of dental practice in the private sector appear to have provided an infertile environment for acceptance of sealants as a primary preventive technology. In the public sector, interest in sealants is high but

  9. Durability of building joint sealants

    Science.gov (United States)

    Christopher C. White; Kar Tean Tan; Donald L. Hunston; R. Sam Williams

    2009-01-01

    Predicting the service life of building joint sealants exposed to service environments in less than real time has been a need of the sealant community for many decades. Despite extensive research efforts to design laboratory accelerated tests to duplicate the failure modes occurring in field exposures, little success has been achieved using conventional durability...

  10. Dental Sealants

    Science.gov (United States)

    ... that protect the chewing surfaces of children’s back teeth from tooth decay. Overall, the prevalence of sealants in children’s and adolescent’s teeth has increased since the early 1970s. In spite ...

  11. Do light cured ART conventional high-viscosity glass-ionomer sealants perform better than resin-composite sealants: a 4-year randomized clinical trial

    NARCIS (Netherlands)

    Zhang, W.; Chen, X.; Fan, M.W.; Mulder, J.; Huysmans, M.C.D.N.J.M.; Frencken, J.E.F.M.

    2014-01-01

    OBJECTIVE: The hypotheses tested were: the cumulative survival rates of dentin caries lesion-free pits and fissures of ART conventional high-viscosity glass-ionomer sealants with light-curing (high-intensity LED) and glass-carbomer sealants are higher than those of conventional ART sealants and

  12. Sealants for preventing dental decay in the permanent teeth

    DEFF Research Database (Denmark)

    Ahovuo-Saloranta, Anneli; Forss, Helena; Walsh, Tanya

    2013-01-01

    of bias and two studies at high risk of bias), 482 children evaluated; risk ratio (RR) 0.24, 95% CI 0.12 to 0.45, one study at unclear risk of bias, 203 children evaluated).- Glass ionomer sealant compared with no sealant: There is insufficient evidence to make any conclusions about whether glass ionomer......, outcomes, time of outcomes reported and background fluoride exposure if this was reported.Fifteen trials compared glass ionomer with resin sealants and there is insufficient evidence to make any conclusions about the superiority of either of the two materials. Although there were 15 trials the event rate...... was very low in many of these which restricted their contribution to the results.Three trials compared resin-modified glass ionomer with resin sealant and reported inconsistent results.Two small low quality trials compared polyacid-modified resin sealants with resin sealants and found no difference...

  13. Dental Sealants Prevent Cavities PSA (:60)

    Centers for Disease Control (CDC) Podcasts

    This 60 second public service announcement is based on the October 2016 CDC Vital Signs report. Dental sealants, applied soon after a child's permanent molars come in, can protect against cavities for up to nine years. Applying sealants in schools for low-income children could save millions in dental treatment costs.

  14. Glass ionomer ART sealants in Chinese school children-6-year results.

    Science.gov (United States)

    Holmgren, Christopher J; Lo, Edward C M; Hu, Deyu

    2013-09-01

    To evaluate longitudinally ART sealants placed in Chinese school children under field conditions. 191 ART sealants were placed in 140 children, aged 11-14 years, by five assistant dentists in four secondary schools in Deyang, Sichuan Province, China. Teeth selected for sealing were those with pits and fissures that were deep or showing early enamel caries. Teeth were excluded if there was obvious cavitation extending into dentine. Standard instruments and procedures for ART sealants were used. The material used was a high-viscosity glass-ionomer (Ketac-Molar, 3MESPE) that was inserted into the pits and fissures with the "press-finger" technique. The status of the sealants was evaluated annually over 6 years after placement by the same examiner who was not involved in the placement of the sealants using explorers, mouth-mirrors and an intra-oral fibre-optic light. No missing sealants were replaced during the study. 107 sealants (56% of the original) were examined after 6 years. The cumulative survival rates of the sealants (partially or fully retained) after 2, 4 and 6 years were 79%, 68% and 59%, respectively. Caries prevention lagged the fall in sealant survival but remained high throughout the study period, being over 90% in the first 4 years and 85% after 6 years. ART sealants placed under field conditions in Chinese schoolchildren have a high retention rate. Missing sealants should be replaced to maintain their preventive efficacy. The sealing of pits and fissures can be an effective caries preventive approach. Resin-based sealants have the disadvantage in that they require an optimal level of moisture control during placement. In children and in outreach situations glass ionomer ART sealants, which are more moisture tolerant, can offer a viable alternative. Copyright © 2013 Elsevier Ltd. All rights reserved.

  15. Fibrin Sealants in Dura Sealing: A Systematic Literature Review.

    Directory of Open Access Journals (Sweden)

    Felice Esposito

    Full Text Available Fibrin sealants are widely used in neurosurgery to seal the suture line, provide watertight closure, and prevent cerebrospinal fluid leaks. The aim of this systematic review is to summarize the current efficacy and safety literature of fibrin sealants in dura sealing and the prevention/treatment of cerebrospinal fluid leaks.A comprehensive electronic literature search was run in the following databases: Cochrane Database of Systematic Reviews, Cochrane Central Resister of Controlled Trials, clinicaltrials.gov, MEDLINE/PubMed, and EMBASE. Titles and abstracts of potential articles of interest were reviewed independently by 3 of the authors.A total of 1006 database records and additional records were identified. After screening for duplicates and relevance, a total of 78 articles were assessed by the investigators for eligibility. Thirty-eight were excluded and the full-text of 40 articles were included in the qualitative synthesis. Seven of these included only safety data and were included in the safety assessment. The remaining 33 articles included findings from 32 studies that enrolled a total of 2935 patients who were exposed to fibrin sealant. Among these 33 studies there were only 3 randomized controlled trials, with the remaining being prospective cohort analysis, case controlled studies, prospective or retrospective case series. One randomized controlled trial, with 89 patients exposed to fibrin sealant, found a greater rate of intraoperative watertight dura closure in the fibrin sealant group than the control group (92.1% versus 38.0%, p0.05. Other clinical trials evaluated the effect of fibrin sealant in the postoperative prevention of cerebrospinal fluid leaks. These were generally lower level evidence studies (ie, not prospective, randomized, controlled trials that were not designed or powered to demonstrate a significant advantage to fibrin sealant use. Two small case series studies evaluated the effect of fibrin sealants in

  16. Development of a Novel Alginate-Based Pleural Sealant

    Science.gov (United States)

    2016-07-01

    thoracotomy is performed on a anesthetized ventilated live rat (a), an incision is made to induce pleural air leak (b), and sealant material [ liquid ...AWARD NUMBER: W81XWH-15-1-0107 TITLE: Development of a Novel Alginate-Based Pleural Sealant PRINCIPAL INVESTIGATOR: Daniel J. Weiss MD PhD...SUBTITLE Development of a Novel Alginate-Based Pleural Sealant 5a. CONTRACT NUMBER 5b. GRANT NUMBER W81XWH-15-1-0107 5c. PROGRAM ELEMENT NUMBER 6. AUTHOR

  17. Role of Fibrin Sealants in Liver Surgery

    NARCIS (Netherlands)

    de Boer, Marieke T.; Boonstra, Elizabeth A.; Lisman, Ton; Porte, Robert J.

    2012-01-01

    Background: Fibrin sealants are widely used in liver surgery. The aim of this article is to review the literature on evidence of hemostatic and biliostatic capacities of different fibrin sealants in liver surgery. Methods: In PubMed, a literature search was done with the search terms 'fibrin

  18. Two-year survival of glass ionomer sealants placed as part of ...

    African Journals Online (AJOL)

    , ... Results: The two-year cumulative survival of the sealants was 10.9%, and the survival of the sealants was not significantly affected by the GIC material brand and the toothisolation method used. However, slightly more sealants survived ...

  19. Dental Sealants Prevent Cavities PSA (:60)

    Centers for Disease Control (CDC) Podcasts

    2016-10-18

    This 60 second public service announcement is based on the October 2016 CDC Vital Signs report. Dental sealants, applied soon after a child's permanent molars come in, can protect against cavities for up to nine years. Applying sealants in schools for low-income children could save millions in dental treatment costs.  Created: 10/18/2016 by National Center for Chronic Disease Prevention and Health Promotion (NCCDPHP).   Date Released: 10/18/2016.

  20. Systematic review on the use of matrix-bound sealants in pancreatic resection.

    Science.gov (United States)

    Smits, F Jasmijn; van Santvoort, Hjalmar C; Besselink, Marc G H; Borel Rinkes, Inne H M; Molenaar, I Quintus

    2015-11-01

    Pancreatic fistula is a potentially life-threatening complication after a pancreatic resection. The aim of this systematic review was to evaluate the role of matrix-bound sealants after a pancreatic resection in terms of preventing or ameliorating the course of a post-operative pancreatic fistula. A systematic search was performed in the literature from May 2005 to April 2015. Included were clinical studies using matrix-bound sealants after a pancreatic resection, reporting a post-operative pancreatic fistula (POPF) according to the International Study Group on Pancreatic Fistula classification, in which grade B and C fistulae were considered clinically relevant. Two were studies on patients undergoing pancreatoduodenectomy (sealants n = 67, controls n = 27) and four studies on a distal pancreatectomy (sealants n = 258, controls n = 178). After a pancreatoduodenectomy, 13% of patients treated with sealants versus 11% of patients without sealants developed a POPF (P = 0.76), of which 4% versus 4% were clinically relevant (P = 0.87). After a distal pancreatectomy, 42% of patients treated with sealants versus 52% of patients without sealants developed a POPF (P = 0.03). Of these, 9% versus 12% were clinically relevant (P = 0.19). The present data do not support the routine use of matrix-bound sealants after a pancreatic resection, as there was no effect on clinically relevant POPF. Larger, well-designed studies are needed to determine the efficacy of sealants in preventing POPF after a pancreatoduodenectomy. © 2015 International Hepato-Pancreato-Biliary Association.

  1. Use of fibrin sealants in cardiovascular surgery: a systematic review.

    Science.gov (United States)

    Rousou, John A

    2013-05-01

    Fibrin sealants are used for hemostasis and tissue adherence. This systematic review summarizes published clinical data for fibrin sealant use in cardiovascular surgery. A literature search for the following terms was conducted using PubMed and EMBASE: (TISSEEL or Tissucol or Beriplast P or Evicel or Quixil or Crosseal or Reliseal or Fibringluraas or Bolheal or Tachosil or Vivostat or Vitagel or Artiss or "fibrin glue" or "fibrin sealant" or "fibrin tissue adhesive") and (cardiac or cardiovascular or vascular or heart or coronary or surgery). Case reports and series were excluded; although reports of controlled trials were preferred, uncontrolled trial data were also considered. Clinical trials and chart review analyses of fibrin sealants were identified and summarized. Although clinical trial data were available for other agents, the majority of published studies examined TISSEEL. Overall, TISSEEL and other fibrin sealants showed improvements over standard of care or control groups for a variety of predefined endpoints. Safety findings are also summarized. Data from these studies showed that fibrin sealants were well tolerated and provided effective hemostasis in a range of cardiac and aortic surgeries. © 2013 Wiley Periodicals, Inc.

  2. Toxicity of coal-tar and asphalt sealants to eastern newts, Notophthalmus viridescens

    Energy Technology Data Exchange (ETDEWEB)

    Bommarito, T.; Sparling, D.W.; Halbrook, R.S. [South Illinois University, Carbondale, IL (United States). Cooperative Wildlife Research Laboratory

    2010-09-15

    Between 1970 and 2000 the concentration of total polycyclic aromatic hydrocarbons (TPAH) in several lakes across the country increased whereas those of other persistent organic pollutants (POPs) tended to remain stable or declined. Urbanized watersheds experienced greater rises in TPAH concentration compared to non-urban lakes. Sources for urban PAHs include industrial wastes, vehicular exhausts and oil leaks and sealants from pavement surfaces. Both coal-tar and asphalt sealants are used to protect surfaces but runoff from surfaces coated with coal-tar can have mean concentrations of 3500 mg TPAHs kg{sup -1}, much higher than runoff from asphalt-sealed or cement surfaces. Unaltered parent compounds of PAHs can have many lethal and sublethal toxic effects, but oxidation and UV radiation can alter the toxicity of these compounds, sometimes creating degradates that are many times more toxic than parent compounds. The purposes of this study were to determine if coal-tar sealants can be toxic to adult eastern newts (Notophthalmus viridescens) and to compare the toxicity of coal-tar sealant to that of asphalt sealant. Newts were exposed to sediments containing dried sealants ranging from 0 mg kg{sup -1} to 1500 mg kg{sup -1} under simultaneous exposure to UV radiation and visible light to determine concentration/response relationships. No significant mortality occurred with any treatment. Significant effects due to sealants included decreased righting ability and diminished liver enzyme activities. Coal-tar sealant was more effective in inducing these changes than was asphalt sealant.

  3. Effect of chain extender on properties of silicone rubber sealant

    Science.gov (United States)

    Liu, Jiesheng; Wu, Shaopeng; Mi, Yixuan; Zhu, Guojun; Zheng, Shaoping

    2010-03-01

    The room-temperature vulcanizing silicone rubber sealant was prepared with chain extender. The effect of chain extender on the properties of silicone rubber sealant was discussed. The composite samples with chain extender were investigated from the aspects of tack-free time, cross-linkage density, hardness (penetration number) and adhesive strength with the concrete slab. It was found that the adding of the chain extender effectively makes the molecular chain length increase and causes the mechanical properties improvement. In addition, the increase in the amount of the chain extender reduces the cross-linkage density and hardness of silicone rubber sealant, which is accompanied with a decrease in the tack-free time. Adhesive strength is one of the most important requirements for sealant. The effect of chain extender on the adhesive strength was also investigated in this study. It was found that the increase in the amount of the chain extender makes the adhesive strength between the sealant and the concrete slab decrease.

  4. A 1-year clinical evaluation of fissure sealants on permanent first molars

    Directory of Open Access Journals (Sweden)

    Nupur Ninawe

    2012-01-01

    Full Text Available Objective : To evaluate and compare the retention, marginal discoloration, surface texture and anatomical form of pit and fissure sealants. Materials and Methods : Thirty children between the ages of 6 and 10 years, who were attending the school health program regularly, had participated in the study. A split-mouth design was used in which the two fissure sealants (Helioseal-F and Glass ionomer Fuji VII were randomly placed in 60 matched contralateral pairs of permanent molar teeth. Sealants were rated by a single trained and calibrated examiner using mouth mirrors and probes following the US Public Health Service criteria. The sealants were evaluated at 3 months, 6 months and 1 year intervals. Results : The data obtained for retention, marginal discoloration, surface texture and anatomical form of pit and fissure sealants were tabulated and compared statistically using the Chi-square test of significance. Conclusion : The Helioseal-F sealant was better than the Glass ionomer Fuji VII sealant with respect to retention, anatomical form and surface texture. Both the materials showed similar results with respect to marginal discoloration.

  5. Tensile strength of biological fibrin sealants: a comparative study.

    Science.gov (United States)

    Lacaze, Laurence; Le Dem, Nicolas; Bubenheim, Michael; Tsilividis, Basile; Mezghani, Julien; Schwartz, Lilian; Francois, Arnaud; Ertaud, Jean Yves; Bagot d'Arc, Maurice; Scotté, Michel

    2012-08-01

    Fibrin sealants are commonly used in liver surgery, although their effectiveness in routine clinical practice remains controversial. Individual sealant characteristics are based on hemostatic effects and adhesion properties that can be experimentally measured using the 'rat skin test' or the 'pig skin test'. This study used a more relevant and realistic experimental canine model to compare the differences in the adhesive properties of four fibrin sealants in hepatectomy: Tisseel/Tissucol, Tachosil, Quixil, and Beriplast. A partial hepatectomy was performed in beagle dogs under general anesthesia to obtain liver cross-sections. Fibrin sealants were allocated to dog livers using a Youden square design. The tensile strength measurement was performed using a traction system to measure the rupture stress point of a small wooden cylinder bonded to the liver cross-section. Significantly greater adhesion properties were observed with Tisseel/Tissucol compared with Quixil or Beriplast (P = 0.002 and 0.001, respectively). Similarly, Tachosil demonstrated significantly greater adhesive properties compared with Beriplast (P = 0.009) or Quixil (P = 0.014). No significant differences were observed between Tisseel/Tissucol and Tachosil or between Beriplast and Quixil. The results of this comparative study demonstrate that different fibrin sealants exhibit different adhesive properties. Tisseel/Tissucol and Tachosil provided greatest adhesion to liver cross-section in our canine model of hepatectomy. These results may enable the optimal choice of fibrin sealants for this procedure in clinical practice. Copyright © 2012 Elsevier Inc. All rights reserved.

  6. Coal-tar based pavement sealant toxicity to freshwater macroinvertebrates

    International Nuclear Information System (INIS)

    Bryer, Pamela J.; Scoggins, Mateo; McClintock, Nancy L.

    2010-01-01

    Non-point-source pollution is a major source of ecological impairment in urban stream systems. Recent work suggests that coal-tar pavement sealants, used extensively to protect parking areas, may be contributing a large portion of the polycyclic aromatic hydrocarbon (PAH) loading seen in urban stream sediments. The hypothesis that dried coal-tar pavement sealant flake could alter the macroinvertebrate communities native to streams in Austin, TX was tested using a controlled outdoor laboratory type approach. The treatment groups were: control, low, medium, and high with total PAH concentrations (TPAH = sum of 16 EPA priority pollutant PAHs) of 0.1, 7.5, 18.4, and 300 mg/kg respectively. The low, medium, and high treatments were created via the addition of dried coal-tar pavement sealant to a sterile soil. At the start of the 24-day exposure, sediment from a minimally impacted local reference site containing a community of live sediment-dwelling benthic macroinvertebrates was added to each replicate. An exposure-dependent response was found for several stream health measures and for several individual taxa. There were community differences in abundance (P = 0.0004) and richness (P < 0.0001) between treatments in addition to specific taxa responses, displaying a clear negative relationship with the amount of coal-tar sealant flake. These results support the hypothesis that coal-tar pavement sealants contain bioavailable PAHs that may harm aquatic environments. - Coal-tar pavement sealants degrade stream invertebrate communities.

  7. Comparison of microleakage between flowable nanocomposite, flowable Composite and Conventional sealant in fissure sealant therapy of the permanent teeth: an in- vitro study

    Directory of Open Access Journals (Sweden)

    Sara Maleki Kambakhsh

    2016-11-01

    Full Text Available Background and Aim: Novel dental materials including nanocomposites have been introduced in recent years. It is claimed that they have superior properties such as high esthetic., low wear, increased filler content resulting in better mechanical properties, and releasing ions i.e. fluoride and amorphous calcium phosphate that are important for enamel remineralization. Considering these features, if they have retention and microleakage rates comparable with conventional sealants, these materials can be appropriate alternatives to conventional resin sealants in future. The current study aimed at comparing . microleakage of a flowable nanocomposite, a flowable composite , and a conventional sealant in fissure sealant therapy of the permanent teeth. Materials and Methods: First of all ,42 extracted sound human maxillary first premolars were collected and were randomly divided into 3 equal groups. Then the teeth were embedded in self-cure acrylic resin. Occlusal fissures of the samples were cleaned using explorer, enameloplasty with ¼ round diamond bur and water/air spray was done. The prepared surfaces were etched using 36% phosphoric acid gel for 15s, rinsed and dried. Bonding agent was placed in the pits and fissures, cured for 10s after thinning with air. In the first, second , and the third group conventional sealant, flowable composite , and flowable nanocomposite were placed, respectively; and light cured for 40s. The samples were thermocycled (1000 cycles between 5-55ºC and then immersed in 2% basic Fuchsine solution for 24hs. They were then cut bucculingually and microleakage evaluation was done using stereomicroscope. The obtained data was analyzed using Kruskal wallis tests. Results: There was no significant difference in microleakage rate of the study groups. (P>0.05. Conclusion: Considering the condition of the study, it can be concluded that flowable composite and flowable nanocomposite can be used as suitable alternatives to

  8. Synthetic phenolic antioxidants, including butylated hydroxytoluene (BHT), in resin-based dental sealants

    Energy Technology Data Exchange (ETDEWEB)

    Wang, Wei; Kannan, Pranav; Xue, Jingchuan [Wadsworth Center, New York State Department of Health, and Department of Environmental Health Sciences, School of Public Health, State University of New York at Albany, Empire State Plaza, P.O. Box 509, Albany, NY 12201-0509 (United States); Kannan, Kurunthachalam, E-mail: Kurunthachalam.kannan@health.ny.gov [Wadsworth Center, New York State Department of Health, and Department of Environmental Health Sciences, School of Public Health, State University of New York at Albany, Empire State Plaza, P.O. Box 509, Albany, NY 12201-0509 (United States); Biochemistry Department, Faculty of Science, Experimental Biochemistry Unit, King Fahd Medical Research Center, King Abdulaziz University, Jeddah (Saudi Arabia)

    2016-11-15

    Resin-based dental sealants (also referred to as pit-and-fissure sealants) have been studied for their contribution to bisphenol A (BPA) exposure in children. Nevertheless, little attention has been paid to the occurrence of other potentially toxic chemicals in dental sealants. In this study, the occurrence of six synthetic phenolic antioxidants (SPAs), including 2,6-di-tert-butyl-4-hydroxytoluene (BHT), 2,6-di-tert-butyl-4-(hydroxyethyl)phenol (BHT-OH), 3,5-di-tert-butyl-4-hydroxy-benzaldehyde (BHT-CHO), 2,6-di-tert-butylcyclohexa-2,5-diene-1,4-dione (BHT-Q), 3,5-di-tert-butyl-4-hydroxybenzoic acid (BHT-COOH) and 2-tert-butyl-4-methoxyphenol (BHA), was examined in 63 dental sealant products purchased from the U.S. market. BHT was found in all dental sealants at median and maximum concentrations of 56.8 and 1020 µg/g, respectively. The metabolites of BHT and BHA were detected in 39–67% of samples, at concentration ranges of sealants to inhibit oxidative reactions, remove free radicals, and inhibit potential polymerization, which would eventually prolong the shelf-life of the products. The estimated daily intake (EDI) of BHT, following sealant placement, based on a worst-case scenario (application on eight teeth at 8 mg each tooth), was 930 and 6510 ng/kg bw/d for adults and children, respectively. The EDI of BHT from dental sealants was several orders of magnitude lower than the current acceptable daily intake (ADI) proposed by the European Food Safety Authority (EFSA). - Highlights: • Synthetic phenolic antioxidants (SPAs) were detected in dental sealants. • 2,6-di-tert-butyl-4-hydroxytoluene (BHT) concentration of up to 1020 µg/g was found. • Estimated daily intake of BHT after sealant placement was up to 9.52 µg/kg bw/d. • Daily intake of BHT through dental sealant application was below the acceptable daily intake.

  9. Synthetic phenolic antioxidants, including butylated hydroxytoluene (BHT), in resin-based dental sealants

    International Nuclear Information System (INIS)

    Wang, Wei; Kannan, Pranav; Xue, Jingchuan; Kannan, Kurunthachalam

    2016-01-01

    Resin-based dental sealants (also referred to as pit-and-fissure sealants) have been studied for their contribution to bisphenol A (BPA) exposure in children. Nevertheless, little attention has been paid to the occurrence of other potentially toxic chemicals in dental sealants. In this study, the occurrence of six synthetic phenolic antioxidants (SPAs), including 2,6-di-tert-butyl-4-hydroxytoluene (BHT), 2,6-di-tert-butyl-4-(hydroxyethyl)phenol (BHT-OH), 3,5-di-tert-butyl-4-hydroxy-benzaldehyde (BHT-CHO), 2,6-di-tert-butylcyclohexa-2,5-diene-1,4-dione (BHT-Q), 3,5-di-tert-butyl-4-hydroxybenzoic acid (BHT-COOH) and 2-tert-butyl-4-methoxyphenol (BHA), was examined in 63 dental sealant products purchased from the U.S. market. BHT was found in all dental sealants at median and maximum concentrations of 56.8 and 1020 µg/g, respectively. The metabolites of BHT and BHA were detected in 39–67% of samples, at concentration ranges of sealants to inhibit oxidative reactions, remove free radicals, and inhibit potential polymerization, which would eventually prolong the shelf-life of the products. The estimated daily intake (EDI) of BHT, following sealant placement, based on a worst-case scenario (application on eight teeth at 8 mg each tooth), was 930 and 6510 ng/kg bw/d for adults and children, respectively. The EDI of BHT from dental sealants was several orders of magnitude lower than the current acceptable daily intake (ADI) proposed by the European Food Safety Authority (EFSA). - Highlights: • Synthetic phenolic antioxidants (SPAs) were detected in dental sealants. • 2,6-di-tert-butyl-4-hydroxytoluene (BHT) concentration of up to 1020 µg/g was found. • Estimated daily intake of BHT after sealant placement was up to 9.52 µg/kg bw/d. • Daily intake of BHT through dental sealant application was below the acceptable daily intake.

  10. Reimbursement rates and policies for primary molar pit-and-fissure sealants across state Medicaid programs.

    Science.gov (United States)

    Chi, Donald L; Singh, Jennifer

    2013-11-01

    Little is known about Medicaid policies regarding reimbursement for placement of sealants on primary molars. The authors identified Medicaid programs that reimbursed dentists for placing primary molar sealants and hypothesized that these programs had higher reimbursement rates than did state programs that did not reimburse for primary molar sealants. The authors obtained Medicaid reimbursement data from online fee schedules and determined whether each state Medicaid program reimbursed for primary molar sealants (no or yes). The outcome measure was the reimbursement rate for permanent tooth sealants (calculated in 2012 U.S. dollars). The authors compared mean reimbursement rates by using the t test (α = .05). Seventeen Medicaid programs reimbursed dentists for placing primary molar sealants (34 percent), and the mean reimbursement rate was $27.57 (range, $16.00 [Maine] to $49.68 [Alaska]). All 50 programs reimbursed dentists for placement of sealants on permanent teeth. The mean reimbursement for permanent tooth sealants was significantly higher in programs that reimbursed for primary molar sealants than in programs that did not ($28.51 and $23.67, respectively; P = .03). Most state Medicaid programs do not reimburse dentists for placing sealants on primary molars, but programs that do so have significantly higher reimbursement rates. Medicaid reimbursement rates are related to dentists' participation in Medicaid and children's dental care use. Reimbursement for placement of sealants on primary molars is a proxy for Medicaid program generosity.

  11. Pit and fissure sealants for preventing dental decay in the permanent teeth of children and adolescents

    DEFF Research Database (Denmark)

    Ahovuo-Saloranta, Anneli; Hiiri, Anne; Nordblad, Anne

    2008-01-01

    BACKGROUND: Although pit and fissure sealants are effective in preventing caries, their efficacy may be related to the caries prevalence in the population. OBJECTIVES: The primary objective of this review was to evaluate the caries prevention of pit and fissure sealants in children and adolescents...... for comparison of sealant versus sealant. Five split-mouth studies and one parallel group study with 5 to 10 year old children found a significant difference in favour of second or third generation resin-based sealants on first permanent molars, compared to a control without sealant, with a pooled RR of 0.13 (95...... sealant group; 27% of sealed surfaces were decayed compared to 77% of surfaces without sealant.The results of the studies comparing different sealant materials were conflicting. AUTHORS' CONCLUSIONS: Sealing is a recommended procedure to prevent caries of the occlusal surfaces of permanent molars...

  12. Coal-tar based pavement sealant toxicity to freshwater macroinvertebrates

    Energy Technology Data Exchange (ETDEWEB)

    Bryer, P.J.; Scoggins, M.; McClintock, N.L. [Lamar University, Beaumont, TX (United States). Dept. of Biology

    2010-05-15

    Non-point-source pollution is a major source of ecological impairment in urban stream systems. Recent work suggests that coal-tar pavement sealants, used extensively to protect parking areas, may be contributing a large portion of the polycyclic aromatic hydrocarbon (PAH) loading seen in urban stream sediments. The hypothesis that dried coal-tar pavement sealant flake could alter the macroinvertebrate communities native to streams in Austin, TX was tested using a controlled outdoor laboratory type approach. The treatment groups were: control, low, medium, and high with total PAH concentrations (TPAH = sum of 16 EPA priority pollutant PAHs) of 0.1, 7.5, 18.4, & 300 mg/kg respectively. The low, medium, and high treatments were created via the addition of dried coal-tar pavement sealant to a sterile soil. At the start of the 24-day exposure, sediment from a minimally impacted local reference site containing a community of live sediment-dwelling benthic macroinvertebrates was added to each replicate. An exposure-dependent response was found for several stream health measures and for several individual taxa. There were community differences in abundance (P = 0.0004) and richness (P < 0.0001) between treatments in addition to specific taxa responses, displaying a clear negative relationship with the amount of coal-tar sealant flake. These results support the hypothesis that coal-tar pavement sealants contain bioavailable PAHs that may harm aquatic environments.

  13. Sealants fight back aginst bacteria.

    Science.gov (United States)

    Moran, Mike

    2008-09-01

    Mike Moran, business development manager, Industrial Construction, at Bostik, explains how a range of new sealants increase protection in hospital bathrooms, shower rooms and kitchen facilities against healthcare-acquired infections.

  14. Evaluation of a sealant intervention program among Taiwanese aboriginal schoolchildren

    Directory of Open Access Journals (Sweden)

    Hui-Ju Hsieh

    2014-06-01

    Conclusion: The application of pit-and-fissure sealants was 94.54% effective in preventing caries on newly erupted permanent molars among Taiwanese aboriginal schoolchildren. Complete sealant failure demonstrated a high risk for caries, and such teeth should immediately be resealed.

  15. Effect of an Antibacterial Monomer on the Antibacterial Activity of a Pit-and-Fissure Sealant.

    Directory of Open Access Journals (Sweden)

    Fan Yu

    Full Text Available Resin-based pit-and-fissure sealants are often used to form a barrier on the occlusal surface of molars to treat caries lesions; however, bacteria can remain in the pit and fissures without detection, increasing the risk of secondary caries. Sealants with antimicrobial properties or microbial repellent actions might be advantageous. The aim of this study was to assess the inhibitory effect of a 2-methacryloxylethyl dodecyl methyl ammonium bromide (MAE-DB-incorporated sealant against Streptococcus mutans. MAE-DB (4% wt was incorporated into a commercially available sealant, Eco-S resin-based pit-and-fissure sealant (Vericom Co., Ltd., Korea; a sealant without MAE-DB served as a negative control, and Clinpro™ Sealant (3M™ ESPE™, a fluoride-releasing resin, was used as a commercial control. The effects of the cured sealants and their eluents on the growth of S. mutans were determined according to colony-forming unit counts and metabolic tests. The effects of the cured sealants on the adherence and membrane integrity of S. mutans were investigated using confocal laser-scanning microscopy (CLSM in conjunction with fluorescent indicators. Compared with the negative control and commercial control, the cured MAE-DB-incorporated pit-and-fissure sealant exhibited a significant inhibitory effect on the growth of S. mutans (P < 0.05, whereas the eluents did not show any detectable antibacterial activity. The commercial control also showed no detectable bactericidal activity. Moreover, the aged experimental material retained its property of contact inhibition of biofilm formation. The fluorescence analysis of CLSM images demonstrated that the cured MAE-DB-incorporated sealant could hamper the adherence of S. mutans and exert a detrimental effect on bacterial membrane integrity. The incorporation of MAE-DB can render a pit-and-fissure sealant with contact antibacterial activity after polymerization via influencing the growth, adherence, and membrane

  16. CDC Vital Signs–Dental Sealants Prevent Cavities

    Centers for Disease Control (CDC) Podcasts

    This podcast is based on the October 2016 CDC Vital Signs report. Dental sealants, applied soon after a child's permanent molars come in, can protect against cavities for up to nine years. Applying sealants in schools for low-income children could save millions in dental treatment costs.

  17. Process for nondestructively testing with radioactive gas using a chill set sealant

    International Nuclear Information System (INIS)

    Gibbons, C.B.

    1975-01-01

    An article surface is nondestructively tested for substantially invisible surface voids by absorbing a radioactive gas thereon. The adsorbed radioactive gas is disproportionately retained on those surfaces presented by the substantially invisible surface voids as compared to the remaining surfaces of the article contacted by the radioactive gas. The radiation released by the radioactive gas remaining adsorbed is used to identify the substantially invisible voids. To immobilize the radioactive gas adjacent or within the surface voids, a sealant composition is provided which is capable of being chill set. The temperatures of the article surface to be tested and the sealant composition are then related so that the article surface is at a temperature below the chill set temperature of the sealant composition and the sealant composition is at a temperature above its chill set temperature. The article portion to be tested is then coated with sealant composition to form a chill set coating thereon of substantially uniform thickness. (U.S.)

  18. Effect of a surface sealant on the color stability of composite resins after immersion in staining solution.

    Science.gov (United States)

    Pedroso, Lauana Borges; Barreto, Luma Franciélle Cabreira; Miotti, Leonardo Lamberti; Nicoloso, Gabriel Ferreira; Durand, Leticia Brandão

    2016-01-01

    This study evaluated the influence of surface sealants on the color stability of 2 different composite resins after immersion in coffee. Four groups were created (n = 10): microhybrid composite, microhybrid with surface sealant, nanofilled composite, and nanofilled composite with surface sealant. Half of the specimens of each group were immersed in distilled water and half were immersed in coffee for 48 hours. Color was measured before and after immersion. Groups with surface sealants presented less color variation when compared with the groups without surface sealants. The nanofilled resin specimens presented the greatest color variation within the groups without sealant. The surface sealant positively influenced the color stability of composite resin specimens immersed in coffee. When surface sealant was not applied, the microhybrid specimens had better color stability than the nanofilled.

  19. The effect of bonding agents on the microleakage of sealant following contamination with saliva

    Directory of Open Access Journals (Sweden)

    Askarizadeh Nahid

    2008-06-01

    Full Text Available Aims : An issue of concern in dentistry is the inadequacy of adhesion and proper sealing following restoration of a tooth, which can lead to marginal leakage. The aim of this study was to evaluate the effect of a bonding agent on the microleakage of a sealant material following contamination with saliva. Materials and Methods : In this experimental research, 48 sound premolars were divided into two groups. The first group received sealant without bonding and the other group was given sealant with bonding. After prophylaxis, the occlusal surfaces were etched with 37% phosphoric acid gel and the teeth were then placed in fresh human saliva for l0 s. Following this, in the first group fissure sealant (Kerr was applied directly and cured; for the second group sealant was placed and cured after bonding (Single Bond; 3M. All samples were thermocycled (500 cycles; between 5°C and 55°C; dwell time of 30 s. Silver nitrate was used as the leakage tracer. The teeth were sectioned. Microleakage evaluation was made by stereomicroscope at 40x magnification and the results were evaluated with the Mann-Whitney U test. Results : In the group that received sealant without bonding extensive microleakage was seen; placement of sealant with bonding significantly reduced microleakage. Conclusion : In the presence of contamination with saliva, use of bonding under the fissure sealant can reduce microleakage

  20. Dental sealant knowledge, opinion, values and practice of Spanish dentists

    Directory of Open Access Journals (Sweden)

    San Martin Laura

    2013-02-01

    Full Text Available Abstract Background Multiple guidelines and systematic reviews recommend sealant use to reduce caries risk. Yet, multiple reports also indicate that sealants are significantly underutilized. This study examined the knowledge, opinions, values, and practice (KOVP of dentists concerning sealant use in the southwest region of Andalusia, Spain. This is a prelude to the generation of a regional plan for improving children’s oral health in Andalusia. Methods The survey’s target population was dentists working in western Andalusia, equally distributed in the provinces of Seville, Cadiz, and Huelva (N=2,047. A convenience sample of meeting participants and meeting participant email lists (N=400 were solicited from the annual course on Community and Pediatric Dentistry. This course is required for all public health sector dentists, and is open to all private sector dentists. Information on the dentist’s KOVP of sealants was collected using four-part questionnaire with 31, 5-point Likert-scaled questions. Results The survey population demographics included 190 men (48% and 206 women (52% with an average clinical experience of 10.6 (± 8.4 years and 9.3 (± 7.5 years, respectively. A significant sex difference was observed in the distribution of place of work (urban/suburb (p=0.001, but no sex differences between working sector (public/private. The mean ± SD values for each of the four KOVP sections for pit and fissure sealants were: knowledge = 3.57 ± 0.47; opinion = 2.48 ± 0.47; value = 2.74 ± 0.52; and practice = 3.48 ± 0.50. No sex differences were found in KOVP (all p >0.4. Independent of sex: knowledge statistically differed by years of experience and place of work; opinion statistically differed by years of experience and sector; and practice statistically differed by years of experience and sector. Less experienced dentists tended to have slightly higher scores (~0.25 on a Likert 1–5 scale. Statistically significant correlations were

  1. Effect of Adhesive Application on Sealant Success: A Clinical Study of Fifth and Seventh Generation Adhesive Systems

    Directory of Open Access Journals (Sweden)

    Vaibhav Tandon

    2016-03-01

    Full Text Available Objectives: The aim of the study was to compare the effect of fifth and seventh generation bonding agent on sealant success.Materials and Methods: Sixty-four school children aged six to nine years received sealants in four permanent molars in a split mouth design, such that each patient received sealant in the first permanent molar with fifth generation bonding agent in one arch and seventh generation bonding agent in the other arch; contra-lateral molars were sealed with sealant alone. The evaluation was carried out at baseline, three months, six months and 12 months, according to the criteria by Feigal et al, in 2000. Chi- square test was used to analyze data at P<0.05 level of significance.Results: Statistically significant differences were found for sealant retention between fifth generation and sealant group, and fifth generation and seventh generation groups; whereas, no significant difference was found for sealant retention between seventh generation and sealant group at three, six and 12 months.Conclusion: As separate etch and rinse steps are not required for seventh generation bonding agents, and almost similar results were obtained for both sealant and seventh generation groups, it can be concluded that application of sealant along with a seventh generation bonding agent may enhance sealant success and can be used for caries prevention in preventive programs.Key words:  Pit and Fissure Sealants; Dental Caries; Adhesives

  2. Marginal leakage of two newer glass-ionomer-based sealant materials assessed using micro-CT.

    NARCIS (Netherlands)

    Chen, X.; Cuijpers, V.M.J.I.; Fan, M.; Frencken, J.E.F.M.

    2010-01-01

    OBJECTIVES: To test newer glass-ionomer-based materials as sealant materials. One glass-ionomer sealant was light-cured to obtain an early setting reaction. The null-hypothesis tested was: there is no difference in marginal leakage of sealants produced with high-viscosity glass-ionomer, with and

  3. Vital Signs: Dental Sealant Use and Untreated Tooth Decay Among U.S. School-Aged Children.

    Science.gov (United States)

    Griffin, Susan O; Wei, Liang; Gooch, Barbara F; Weno, Katherine; Espinoza, Lorena

    2016-10-21

    Tooth decay is one of the greatest unmet treatment needs among children. Pain and suffering associated with untreated dental disease can lead to problems with eating, speaking, and learning. School-based dental sealant programs (SBSP) deliver a highly effective intervention to prevent tooth decay in children who might not receive regular dental care. SBSPs benefits exceed their costs when they target children at high risk for tooth decay. CDC used data from the National Health and Nutrition Examination Survey (NHANES) 2011-2014 to estimate current prevalences of sealant use and untreated tooth decay among low-income (≤185% of federal poverty level) and higher-income children aged 6-11 years and compared these estimates with 1999-2004 NHANES data. The mean number of decayed and filled first molars (DFFM) was estimated for children with and without sealants. Averted tooth decay resulting from increasing sealant use prevalence was also estimated. All reported differences are significant at pdental sealant use has increased; however, most children have not received sealants. Increasing sealant use prevalence could substantially reduce untreated decay, associated problems, and dental treatment costs.

  4. Sealants in dentistry: outcomes of the ORCA saturday afternoon symposium 2007

    NARCIS (Netherlands)

    Splieth, C.H.; Ekstrand, K.R.; Alkilzy, M.; Clarkson, J.; Meyer-Lueckel, H.; Martignon, S.; Paris, S.; Pitts, N.B.; Rickets, D.N.; van Loveren, C.

    2010-01-01

    Sealants are a successful tool in caries prevention, but their role in preventive strategies after the caries decline has to be discussed. A survey of paediatric departments across Europe revealed that indications for pit and fissure sealants vary considerably, both nationally and internationally.

  5. Sealants in dentistry: outcomes of the ORCA Saturday Afternoon Symposium 2007

    DEFF Research Database (Denmark)

    Splieth, C H; Ekstrand, K R; Alkilzy, M

    2009-01-01

    Sealants are a successful tool in caries prevention, but their role in preventive strategies after the caries decline has to be discussed. A survey of paediatric departments across Europe revealed that indications for pit and fissure sealants vary considerably, both nationally and internationally...

  6. Evaluation of microtensile bond strength of different fissure sealants to bovine enamel.

    Science.gov (United States)

    Sen Tunc, E; Bayrak, S; Tuloglu, N; Ertas, E

    2012-03-01

    The aim of this study was to evaluate the microtensile bond strength (μTBS) of a new fissure sealant and compare it with conventional sealants which are applied to enamel alone, and also with self-etch and etch-and-rinse adhesives. Enamel specimens were prepared and randomly distributed into three groups according to fissure sealant (Aegis, Helioseal F, Helioseal Clear). Each group was then subdivided according to adhesive system (Clearfil S3, Single Bond, no adhesive). A universal testing machine was used to measure μTBS, and data were analysed using one-way ANOVA and Tukey's tests. μTBS values for all Aegis subgroups were significantly lower than for comparable Helioseal F and Helioseal Clear subgroups (p 0.05). In the Helioseal Clear group, μTBS values for Single Bond were significantly higher than for Clearfil S3 (p adhesive subgroups in the Aegis or Helioseal F groups (p > 0.05). Sealant μTBS values may be affected by material content. The addition of an adhesive may improve μTBS values of sealant to enamel. © 2012 Australian Dental Association.

  7. Effectiveness of two new types of sealants: retention after 2 years

    NARCIS (Netherlands)

    Chen, X.; Du, M.; Fan, M.; Mulder, J.; Huysmans, M.C.; Frencken, J.E.

    2012-01-01

    The hypotheses tested were: survival rate of fully and partially retained glass-carbomer sealants is higher than those of high-viscosity glass-ionomer, with and without energy supplied, and that of resin composite; survival rate of fully and partially retained sealants of high-viscosity

  8. PERBEDAAN TOPICAL FLUORIDE APPLICATION DAN FISSURE SEALANT DALAM MENCEGAH KARIES PADAGIGI MOLAR SATU

    Directory of Open Access Journals (Sweden)

    Pawarti Pawarti

    2017-07-01

    Full Text Available Abstract: Topical Fluoride Application And Fissure Sealant To Prevent Dental Caries Permanent First Molars. Anatomy pits and fissures of teeth are caries initiation vulnerable areas of the permanent molars that grow at the age of 6 years where children can not perform oral hygiene. Caries prevention can be done by closing the pits and fissures or application of fluoride (topical fluoride application on the surface of the teeth. The purpose of this study was to analyze the difference fissure sealants and topical application of fluoride to prevent dental caries of first permanent molars. This study was a quasi-experimental study with time series, a sample was taken by purposive 117-second grade students of SDN District of North Pontianak. Data were analyzed using t-test. The result showed that fissure sealant more effective in caries prevention of first permanent molar than topical fluoride application where there were none caries teeth after and month fissure sealant, 25% sealant partially off and 11% fully off. Teeth that have done fluoride after 6 months of 3.9% of dental caries, the eighth month of 5.4% of dental caries. There was a significant difference between the effectiveness of fissure sealants with topical application of fluoride to prevent dental caries in first permanent molars p-value < 0.05, after 6-month p-value: 0.004 and after 8-month p-value: 0.001. Abstrak: Topical Fluoride Application Dan Fissure Sealant Untuk Mencegah Karies Pada Gigi Molar Satu Permanen. Anatomi pit dan fisura gigi merupakan daerah rentan inisiasi karies gigi molar satu permanen yang tumbuh pada usia 6 tahun anak belum bisa melakukan kebersihan mulutnya. Pencegahan karies dapat dilakukan dengan cara menutup pit dan fissure atau pengolesan fluor (topical fluoride application pada permukaan gigi. Tujuan penelitian ini untuk menganalisis perbedaan efektivitas fissure sealant dan topical fluoride application untuk mencegah karies gigi molar satu permanen anak

  9. Pit and fissure sealants for preventing dental decay in permanent teeth

    DEFF Research Database (Denmark)

    Ahovuo-Saloranta, Anneli; Forss, Helena; Walsh, Tanya

    2017-01-01

    to 3 August 2016), and Embase Ovid (1980 to 3 August 2016). We searched ClinicalTrials.gov and the World Health Organization International Clinical Trials Registry Platform for ongoing trials to 3 August 2016. No restrictions were placed on language or date of publication. Selection criteria......Background: Dental sealants were introduced in the 1960s to help prevent dental caries, mainly in the pits and fissures of occlusal tooth surfaces. Sealants act to prevent bacteria growth that can lead to dental decay. Evidence suggests that fissure sealants are effective in preventing caries....... Further research with long follow-up is needed....

  10. The economics of pit and fissure sealants in preventive dentistry: a review.

    Science.gov (United States)

    Kitchens, Dinah H

    2005-08-15

    Oral diseases are progressive, cumulative, and become more intricate to treat with advancement. While dental caries is an infectious transmissible disease with children being at the highest risk, primary prevention can reduce this risk. Primary prevention in dentistry is usually considered to be community fluoridated water supplies, professional fluoride treatments, and pit and fissure sealants. While community fluoridated water supplies have been proven to be cost-effective, the cost-effectiveness of pit and fissure sealants has primarily been studied in school-based programs of children from low socio-economic backgrounds. Dental sealant programs are just one way to help increase primary prevention in the oral health disparities of children. The purpose of this paper is to review the literature regarding the cost-effectiveness of pit and fissure sealants as a preventive strategy in preventive dentistry.

  11. Self-Healable and Reprocessable Polysulfide Sealants Prepared from Liquid Polysulfide Oligomer and Epoxy Resin.

    Science.gov (United States)

    Gao, Wentong; Bie, Mengyao; Liu, Fu; Chang, Pengshan; Quan, Yiwu

    2017-05-10

    Polysulfide sealants have been commercially applied in many industrial fields. In this article, we study the self-healing property of the epoxy resin-cured polysulfide sealants for the first time. The obtained sealants showed a flexible range of ultimate elongation of 157-478% and a tensile strength of 1.02-0.75 MPa corresponding to different polysulfide oligomers. By taking advantage of the dynamic reversible exchange of disulfide bonds, polysulfide sealants exhibited good self-healing ability under a moderate thermal stimulus. A higher molecular weight and a lower degree of cross-linking of polysulfide oligomer were helpful in improving the ultimate elongation and healing efficiency of the polysulfide sealants. After subjecting to a temperature of 75 °C for 60 min, both the tensile strength and ultimate elongation of a fully cut sample, LP55-F, were restored to 91% of the original values, without affecting the sealing property. Furthermore, the sample exhibited excellent reshaping and reprocessing abilities. These outcomes offer a paradigm toward sustainable industrial applications of the polysulfide-based sealants.

  12. Coal-tar based pavement sealant toxicity to freshwater macroinvertebrates.

    Science.gov (United States)

    Bryer, Pamela J; Scoggins, Mateo; McClintock, Nancy L

    2010-05-01

    Non-point-source pollution is a major source of ecological impairment in urban stream systems. Recent work suggests that coal-tar pavement sealants, used extensively to protect parking areas, may be contributing a large portion of the polycyclic aromatic hydrocarbon (PAH) loading seen in urban stream sediments. The hypothesis that dried coal-tar pavement sealant flake could alter the macroinvertebrate communities native to streams in Austin, TX was tested using a controlled outdoor laboratory type approach. The treatment groups were: control, low, medium, and high with total PAH concentrations (TPAH = sum of 16 EPA priority pollutant PAHs) of 0.1, 7.5, 18.4, & 300 mg/kg respectively. The low, medium, and high treatments were created via the addition of dried coal-tar pavement sealant to a sterile soil. At the start of the 24-day exposure, sediment from a minimally impacted local reference site containing a community of live sediment-dwelling benthic macroinvertebrates was added to each replicate. An exposure-dependent response was found for several stream health measures and for several individual taxa. There were community differences in abundance (P = 0.0004) and richness (P pavement sealants contain bioavailable PAHs that may harm aquatic environments. Copyright 2009 Elsevier Ltd. All rights reserved.

  13. Does Fibrin Sealant Reduce Seroma after Immediate Breast Reconstruction Utilizing a Latissimus Dorsi Myocutaneous Flap?

    Directory of Open Access Journals (Sweden)

    Han Gyu Cha

    2012-09-01

    Full Text Available Background The most common complication of latissimus dorsi myocutaneous flap in breastreconstruction is seroma formation in the back. Many clinical studies have shown that fibrinsealant reduces seroma formation. We investigated any statistically significant differences inpostoperative drainage and seroma formation when utilizing the fibrin sealant on the site ofthe latissimus dorsi myocutaneous flap harvested for immediate breast reconstruction afterskin-sparing partial mastectomy.Methods A total of 46 patients underwent immediate breast reconstruction utilizing alatissimus dorsi myocutaneous island flap. Of those, 23 patients underwent the procedurewithout fibrin sealant and the other 23 were administered the fibrin sealant. All flaps wereelevated with manual dissection by the same surgeon and were analyzed to evaluate thepotential benefits of the fibrin sealant. The correlation analysis and Mann-Whitney U testwere used for analyzing the drainage volume according to age, weight of the breast specimen,and body mass index.Results Although not statistically significant, the cumulative drainage fluid volume was higherin the control group until postoperative day 2 (530.1 mL compared to 502.3 mL, but thefibrin sealant group showed more drainage beginning on postoperative day 3. The donor sitecomparisons showed the fibrin sealant group had more drainage beginning on postoperativeday 3 and the drain was removed 1 day earlier in the control group.Conclusions The use of fibrin sealant resulted in no reduction of seroma formation. Becausethe benefits of the fibrin sealant are not clear, the use of fibrin sealant must be fully discussedwith patients before its use as a part of informed consent.

  14. A review of bioceramics and fibrin sealant.

    Science.gov (United States)

    Le Guéhennec, L; Layrolle, P; Daculsi, G

    2004-09-13

    This review focuses on bone substitute composites made by mixing ceramic biomaterials with fibrin sealants. Different biomaterials such as coral, bone-derived materials, bioactive glass ceramics, and synthetic calcium phosphate have been mixed with fibrin sealant, resulting in a combination of the biological properties of the two components. This type of association has not produced identical results in all studies. In the past for some, the addition of fibrin sealant to the biomaterial failed to produce any significant, positive effect on osteointegration, whereas others found a positive impact on bone colonization. Despite the negative biological effects reported previously, bioceramic-fibrin composites have been widely used in various types of bone surgery because they are easy to manipulate. In particular, the intra-operative preparation of these composites makes it possible to add bone growth factors or autologous osteoprogenitor cells prior to bone reconstruction. The bone growth factors and autologous osteoprogenitor cells associated with the bioceramic-fibrin composites should provide surgeons with tissue engineered grafts with enhanced osteointegrative properties. This review discusses both the advantages and disadvantages, as well as the future perspectives, of using bioceramic-fibrin composites in various clinical indications.

  15. A Review of Bioceramics and Fibrin Sealant

    Directory of Open Access Journals (Sweden)

    Le Guéhennec L.

    2004-09-01

    Full Text Available This review focuses on bone substitute composites made by mixing ceramic biomaterials with fibrin sealants. Different biomaterials such as coral, bone-derived materials, bioactive glass ceramics, and synthetic calcium phosphate have been mixed with fibrin sealant, resulting in a combination of the biological properties of the two components. This type of association has not produced identical results in all studies. In the past for some, the addition of fibrin sealant to the biomaterial failed to produce any significant, positive effect on osteointegration, whereas others found a positive impact on bone colonization. Despite the negative biological effects reported previously, bioceramic-fibrin composites have been widely used in various types of bone surgery because they are easy to manipulate. In particular, the intra-operative preparation of these composites makes it possible to add bone growth factors or autologous osteoprogenitor cells prior to bone reconstruction. The bone growth factors and autologous osteoprogenitor cells associated with the bioceramic-fibrin composites should provide surgeons with tissue engineered grafts with enhanced osteointegrative properties. This review discusses both the advantages and disadvantages, as well as the future perspectives, of using bioceramic-fibrin composites in various clinical indications.

  16. Glass Composition for the use as a Sealant

    DEFF Research Database (Denmark)

    2014-01-01

    The invention concerns a glass composition for the use as a sealant, particularly in a solid oxide fuel cell (SOFC) or in a solid oxide electrolyser cell (SOEC). The glass composition comprises 35-70 mol% CaO, 5-45 mol% ZnO, 5-50 mol% B2O3, 1-45 mol% SiO2, and 1 mol% or less of each element...... of the group, comprising Ba, Na and Sr, based on the total glass composition. Furthermore, the invention relates to an SOFC and an SOEC employing a sealant of said glass composition....

  17. Treatment of venous ulcers with fibrin sealant derived from snake venom

    Directory of Open Access Journals (Sweden)

    MAN Gatti

    2011-01-01

    Full Text Available Venous ulcers of the lower limbs complicated by infection or chronicity represent a serious public health problem. The elevated number of those afflicted burdens the health services, interferes in quality of life and causes absenteeism. Although there are 2,500 items on the market, ranging from the simplest dressing up to the most complex types of dressing, treatment remains a challenge. Among the substances used, fibrin sealant is the one that promotes diminution of bacterial colonization and of edema, controls hemorrhaging, alters the pain threshold by protecting the nerve endings, hydrates the wound bed and forms granulation tissue that favors healing. Its disadvantages include higher cost and utilization of human fibrinogen that can transmit infectious diseases. The Center for the Study of Venoms and Venomous Animals (CEVAP at São Paulo State University (UNESP developed a new sealant made up of fibrinogen extracted from large animals and from an enzyme obtained from snake venom. The present study, developed in the Health Education Clinic (CEPS of Sacred Heart University (USC aimed to evaluate the effect of the new sealant on the healing process of venous ulcers in 24 adult patients, seven of whom were male and 17 female. Two study groups were formed as follows: Group 1 (G1 - control group of 11 patients treated with essential fatty acid (EFA and Unna's boot, and Group 2 (G2 - 13 patients treated with essential fatty acid (EFA, fibrin sealant and Unna's boot. The follow-up lasted eight weeks and the sealant was applied at only the first and fourth weeks. The results showed that Group 2 presented worse lesion conditions as to healing, but, when comparing the two groups, it was noteworthy that the the sealant was effective in healing venous ulcers. There is evidence that the new sealant is recommended for leg ulcers with the following advantages: ease of application, preparation of the wound bed, diminution of pain and a higher number of

  18. Evaluation of pavement joint sealants :a new testing technique

    OpenAIRE

    Abo-Qudais, Saad A.

    1992-01-01

    A new method to evaluate the performance of sealants, used in rigid pavement joints, was developed. A special fixture was designed to transfer cyclic in-line deflection, applied by a testing machine, to cyclic normal and shear deflections on a sealant sandwiched between two-2 x 2 x 2 in. portland cement mortar cubes. The normal and shear deflections were applied simultaneously at a specific ratio controlled by the developed fixture. The new testing method simulates field ...

  19. A comparison between three different pit and fissure sealants with regard to marginal integrity.

    Science.gov (United States)

    Fernandes, Kristlee Sabrin; Chalakkal, Paul; de Ataide, Ida de Noronha; Pavaskar, Rajdeep; Fernandes, Precylia Philo; Soni, Harleen

    2012-04-01

    THE AIM OF THIS STUDY IS TO COMPARE THE OCCURRENCE OF ENAMEL FRACTURES, SEALANT FRACTURES AND MARGINAL FISSURES AFTER PLACEMENT OF THREE SEALANTS: Helioseal F, Conseal F and Clinpro. Thirty individuals between 13 and 15 years of age, diagnosed with pit and fissure caries by visual and DIAGNOdent examination, were chosen for sealant placement on their mandibular molars. The sealants were placed at random, after which, impressions were made with polyvinyl siloxane and casts were fabricated. Dies were prepared, each of which were sputter coated with gold in order to be examined under a scanning electron microscope. The following morphologies were analyzed from dies from each of the sealant groups: Continuous margins, sealant fractures, marginal fissures and enamel fractures. After six months, they were recalled for impression making. Dies were prepared and microscopically analyzed as mentioned. Based on the time of evaluation, there were two groups: Initial group (soon after placement) and final group (after six months). Statistical analysis was done using the paired 't' test and One-way analysis of variance (ANOVA). Clinpro had the greatest fracture resistance, followed by Conseal F and Helioseal F. The occurrence of marginal fissure was found to be least with Clinpro.

  20. Impact of adhesive and photoactivation method on sealant integrity and polymer network formation

    Directory of Open Access Journals (Sweden)

    Boniek Castillo Dutra Borges

    2012-06-01

    Full Text Available We evaluated the influence of photoactivation method and hydrophobic resin (HR application on the marginal and internal adaptation, hardness (KHN, and crosslink density (CLD of a resin-based fissure sealant. Model fissures were created in bovine enamel fragments (n = 10 and sealed using one of the following protocols: no adhesive system + photoactivation of the sealant using continuous light (CL, no adhesive system + photoactivation of the sealant using the soft-start method (SS, HR + CL, or HR + SS. Marginal and internal gaps and KHN were assessed after storage in water for 24 h. The CLD was indirectly assessed by repeating the KHN measurement after 24 h of immersion in 100% ethanol. There was no difference among the samples with regard to marginal or internal adaptation. The KHN and CLD were similar for samples cured using either photoactivation method. Use of a hydrophobic resin prior to placement of fissure sealants and curing the sealant using the soft-start method may not provide any positive influence on integrity or crosslink density.

  1. PAH volatilization following application of coal-tar-based pavement sealant

    Science.gov (United States)

    Van Metre, Peter C.; Majewski, Michael S.; Mahler, Barbara J.; Foreman, William T.; Braun, Christopher L.; Wilson, Jennifer T.; Burbank, Teresa L.

    2012-01-01

    Coal-tar-based pavement sealants, a major source of PAHs to urban water bodies, have recently been identified as a source of volatile PAHs to the atmosphere. We tracked the volatilization of PAHs for 1 year after application of a coal-tar-based pavement sealant by measuring gas-phase PAH concentrations above the pavement surface and solid-phase PAH concentrations in sealant scraped from the surface. Gas-phase concentrations at two heights (0.03 and 1.28 m) and wind speed were used to estimate volatilization flux. The sum of the concentrations of eight frequently detected PAHs (ΣPAH8) in the 0.03-m sample 1.6 h after application (297,000 ng m-3) was about 5000 times greater than that previously reported for the same height above unsealed parking lots (66 ng m-3). Flux at 1.6 h after application was estimated at 45,000 μg m-2 h-1 and decreased rapidly during the 45 days after application to 160 μg m-2 h-1. Loss of PAHs from the adhered sealant also was rapid, with about a 50% decrease in solid-phase ΣPAH8 concentration over the 45 days after application. There was general agreement, given the uncertainties, in the estimated mass of ΣPAH8 lost to the atmosphere on the basis of air sampling (2–3 g m-2) and adhered sealant sampling (6 g m-2) during the first 16 days after application, translating to a loss to the atmosphere of one-quarter to one-half of the PAHs in the sealcoat product. Combining the estimated mass of ΣPAH8 released to the atmosphere with a national-use estimate of coal-tar-based sealant suggests that PAH emissions from new coal-tar-based sealcoat applications each year (~1000 Mg) are larger than annual vehicle emissions of PAHs for the United States.

  2. 76 FR 59087 - Approval and Promulgation of Air Quality Implementation Plans; Delaware; Adhesives and Sealants Rule

    Science.gov (United States)

    2011-09-23

    ... Promulgation of Air Quality Implementation Plans; Delaware; Adhesives and Sealants Rule AGENCY: Environmental... manufacture, sale, use, or application of adhesives, sealants, primers, and solvents. This action is being... consists of Delaware's regulation for reducing VOCs from commercially-used adhesive and sealant products by...

  3. Do fibrin sealants impact negative outcomes after robot-assisted partial nephrectomy?

    Science.gov (United States)

    Cohen, Jason; Jayram, Gautam; Mullins, Jeffrey K; Ball, Mark W; Allaf, Mohamad E

    2013-10-01

    Contemporary rates of postoperative hemorrhage after partial nephrectomy (PN) are low. Commercially available hemostatic agents are commonly used during this surgery to reduce this risk despite a paucity of data supporting the practice. We assessed the impact of fibrin sealant hemostatic agents, a costly addition to surgeries, during robot-assisted partial nephrectomy (RAPN). Between 2007 and 2011, 114 consecutive patients underwent RAPN by a single surgeon (MEA). Evicel fibrin sealant was used in the first 74 patients during renorraphy. The last 40 patients had renorraphy performed without the use of any hemostatic agents. Clinicopathologic, operative, and complication data were compared between groups. Multivariate and univariate logistic regression analysis was performed to test the association between the use of fibrin sealants and operative outcomes. Patient demographic data and clinical tumor characteristics were similar between groups. The use of fibrin sealant did not increase operative time (166.3 vs 176.1 minutes, P=0.28), warm ischemia time (WIT) (14.4 vs 16.1 minutes, P=0.18), or length of hospital stay (2.6 vs 2.4 days, P=0.35). The omission of these agents did not increase estimated blood loss (116.6 vs 176.1 mL, P=0.8) or postoperative blood transfusion (0% vs 2.5%, P=0.17). Univariate analysis demonstrated no association between use of fibrin sealants and increased complications (P>0.05). Multivariable logistic regression showed no statistically significant predictive value of omission of hemostatic agents for perioperative outcomes (P>0.05). Perioperative hemorrhage and other major complications after contemporary RAPN are rare in experienced hands. In our study, the use of fibrin sealants during RAPN does not decrease the rate of complications, blood loss, or hospital stay. Furthermore, no impact is seen on operative time, WIT, or other negative outcomes. Omitting these agents during RAPN could be a safe, effective, cost-saving measure.

  4. Estimating emissions from adhesives and sealants uses and manufacturing for environmental risk assessments.

    Science.gov (United States)

    Tolls, Johannes; Gómez, Divina; Guhl, Walter; Funk, Torsten; Seger, Erich; Wind, Thorsten

    2016-01-01

    Regulation (EC) No 1907/2006 concerning the Registration, Evaluation, Authorisation and Restriction of Chemicals (REACH) requires that environmental exposure assessments be performed for all uses of dangerous substances that are marketed in the European Union in quantities above 10 tons per year. The quantification of emissions to the environment is a key step in this process. This publication describes the derivation of release factors and gives guidance for estimating use rates for quantifying the emissions from the manufacturing and application of adhesives and sealants. Release factors available for coatings and paints are read across to adhesives or sealants based on similarities between these 2 product groups with regard to chemical composition and to processing during manufacturing and application. The granular emission scenarios in these documents are mapped to the broad emission scenarios for adhesives or sealants. According to the mapping, the worst-case release factors for coatings or paints are identified and assigned to the adhesives or sealants scenarios. The resulting 10 specific environmental release categories (SPERCs) for adhesives and sealants are defined by differentiating between solvent and nonsolvent ingredients and between water-borne and solvent-borne or solvent-free products. These cover the vast majority of the production processes and uses and are more realistic than the 5 relevant emission estimation defaults provided in the REACH guidance. They are accompanied with adhesive or sealant consumption rates in the EU and with guidance for estimating conservative substance use rates at a generic level. The approach of combining conservative SPERC release factors with conservative estimates of substance rates is likely to yield emission estimates that tend to overpredict actual releases. Because this qualifies the approach for use in lower-tier environmental exposure assessment, the Association of the European Adhesive & Sealant Industry

  5. Retention of fissure sealants in young permanent molars affected by dental fluorosis: a 12-month clinical study.

    Science.gov (United States)

    Hasanuddin, S; Reddy, E R; Manjula, M; Srilaxmi, N; Rani, S T; Rajesh, A

    2014-10-01

    To evaluate and compare retention and caries occurance following placement of Clinpro and FUJI VII fissure sealants, by two different techniques simultaneously in unsealed, contralateral young permanent molars of 7- to 10-year-old children affected by mild to moderate dental fluorosis at various recall intervals of 1 week, 1, 3, 6 and 12 months. 80 schoolchildren with mild to moderate dental fluorosis were assigned to Group A and Group B with 40 children in each group. In Group A Clinpro fissure sealant and in Group B Fuji VII fissure sealant was used. In both the groups fissure sealants were applied by conventional fissure sealant technique (CST) on one side and enameloplasty sealant technique (EST) on the other side of the same arch. The applied fissure sealants were evaluated clinically for retention and caries incidence. Clinpro fissure sealant showed a retention rate of 95% when compared with Fuji VII (57.5%) at the end of 12 months, which was statistically significant. Regarding techniques, EST showed better results than CST in both the groups. Comparison of groups with respect to retention and techniques at different time periods was performed using Mann-Whitney U test (p < 0.05). Comparison of different time periods with respect to retention and technique in all the groups was performed using Wilcoxon matched pairs test by ranks (p < 0.05). Clinpro fissure sealant showed better retention at all treatment intervals, when compared with Fuji VII. Further follow-up is required to study the efficacy of the fissure sealant placement techniques.

  6. CDC Vital Signs–Dental Sealants Prevent Cavities

    Centers for Disease Control (CDC) Podcasts

    2016-10-18

    This podcast is based on the October 2016 CDC Vital Signs report. Dental sealants, applied soon after a child's permanent molars come in, can protect against cavities for up to nine years. Applying sealants in schools for low-income children could save millions in dental treatment costs.  Created: 10/18/2016 by National Center for Chronic Disease Prevention and Health Promotion (NCCDPHP).   Date Released: 10/18/2016.

  7. Caries detection methods : Can they aid decision making for invasive sealant treatment?

    NARCIS (Netherlands)

    Pereira, AC; Verdonschot, EH; Huysmans, M

    2001-01-01

    The decision to place sealants is a difficult one, and it has been suggested that in a low risk population it may be efficient to wait until caries is detected in the fissure. An invasive sealant technique with fissure preparation may then be indicated. The diagnostic method used in the indication

  8. Microtensile Bond Strength of Embrace Wetbond Hydrophilic Sealant in Different Moisture Contamination: An In-Vitro Study.

    Science.gov (United States)

    Panigrahi, Antarmayee; Srilatha, K T; Panigrahi, Rajat G; Mohanty, Susant; Bhuyan, Sanat K; Bardhan, Debojyoti

    2015-07-01

    Contamination of etched enamel with saliva has been shown to result in sealant failure. Recently, a hydrophilic sealant has been introduced. In absence of documented literature, this in vitro study was undertaken to ascertain the efficacy of Embrace Wet Bond without reduction of microtensile bond strength in the different moisture contamination. A 5mm block of sealant were built over prepared occlusal surface of 40 non-carious therapeutically extracted third molars which were sectioned into 1mm thick stick and tested using Zwick micro tensile tester. Obtained data were subjected to descriptive analysis, one-way ANOVA and Scheffe's post-hoc tests. Mean microtensile bond strength of Embrace sealant was not significantly lowered in different moisture contamination groups except Group 3 (air drying), which showed very highly significant (p<0.001) decrease in μTBS as compared to Group 1 (non-contaminated). Mean μTBS of Embrace sealant remains largely unchanged even in presence of moisture. Owing to its hydrophilic property, this sealant can be a great help in cases where maintaining isolation is difficult.

  9. Survival of sealants in molars affected by molar-incisor hypomineralization: 18-month follow-up

    Directory of Open Access Journals (Sweden)

    Camila Maria Bullio FRAGELLI

    2017-04-01

    Full Text Available Abstract The objective of this study was to evaluate the clinical survival of sealants applied in first permanent molars (FPMs affected by molar-incisor hypomineralization (MIH, at 18 months of follow-up. Forty-one first permanent molars were selected from 21 children, 6–8 years of age. MIH was classified by one calibrated examiner (kappa = 0.80 according to EAPD criteria. The inclusion criteria were fully erupted FPMs with MIH or sound FPMs (without MIH for which sealant treatment was indicated. The FPMs were assigned to two groups: CG (control group and HG (MIH group. Both groups were treated with sealant (FluroShield. Clinical follow-up was performed from baseline to 18 months to assess anatomical form, marginal adaptation, retention and presence of caries, according to criteria set by the United States Public Health Service-Modified, and was conducted by a blinded examiner (kappa = 0.80. The actuarial method was used to evaluate the survival of the sealants. The survival rates for the groups were compared using Fisher’s exact test (α = 5%. The cumulative survival rates were 81% at 1 month, 68.8% at 6 months, 68.8% at 12 months, and 62.6% at 18 months for CG, and 88% at 1 month, 84% at 6 months, 76% at 12 months, and 72% at 18 months for HG. No significant difference was found between the groups. The sealants in molars affected by MIH presented a survival rate similar to the sealants in the control, suggesting that sealants may be an adequate approach for preventing carious lesions in MIH-affected molars.

  10. Microleakage, adaptation ability and clinical efficacy of two fluoride releasing fissure sealants

    Directory of Open Access Journals (Sweden)

    Marković Dejan

    2012-01-01

    Full Text Available Background/Aim. Retention of fissure sealants and good adaptation to enamel are essential for their success. Fluoride releasing resin-based materials are widely accepted for pit and fissure sealing, but newly designed glass ionomers can serve as a good alternative. The aim of this study was to evaluate microleakage and sealing ability in vitro, and to clinically assess two fluoride releasing fissure sealants. Methods. The sample for experimental study consisted of 20 freshly extracted intact human third molars, divided in two experimental groups according to the sealing material: fluoride releasing resin-based (Heliosel F and glass ionomer (Fuji Triage material. Digital images and scanning electron microscope were used to assess microleakage and adaptation ability. Sample for clinical study consisted of 60 children, aged 6-8 years, with high caries risk, divided in two groups according to the sealant material. Fissure sealant was applied to all erupted, caries-free first permanent molars. Sealants were evaluated after 3, 6 and 12 months using modified Ryge criteria for retention, marginal adaptation, colour match, surface smoothness and caries. Results. Microleakage was detected in more than half of the specimen, without significant differences between the two groups (p > 0.05. Both materials exhibited acceptable sealing ability. Complete retention at the end of the observation period was 81.8% for resin-based, and 21.1% for glass-ionomer fissure sealant (p < 0.001. The presence of caries in sealed molars has been detected in one patient in both groups. During the 12-month observation period, Helioseal F demonstrated better retention, marginal adaptation and surface smoothness (p < 0.001. There were no differences between the two materials regarding caries and color match (p > 0.05. Conclusion. Both tested materials demonstrate satisfactory clinical and caries prophylactic characteristics that justify their use in contemporary preventive

  11. Comparison of various concentrations of tricalcium phosphate nanoparticles on mechanical properties and remineralization of fissure sealants.

    Directory of Open Access Journals (Sweden)

    Sara Tavassoli-Hojjati

    2014-08-01

    Full Text Available The aim of this study was to investigate the mechanical properties (flexural strength, micro-shear bond strength and remineralizing potential of fissure sealants by adding various concentrations of β-tricalcium phosphate nanoparticles.This in-vitro study consisted of five experimental groups containing prepared nano-fisssure sealants (1-5 wt.% β-TCP nanoparticles and two control groups containing a prepared and a commercial fissure sealant. Flexural/micro-shear bond strength values were measured using Zwick test machine. Cavities on sixty healthy premolar teeth were filled with the fissure sealants containing 0-5 wt.% of nano β-TCP. The samples were assessed for remineralization under scanning electron microscopy (SEM and EDAX. Kolmogorov-Smirnov test, One-way ANOVA and Tukey's Post Hoc analysis/HSD were used to analyze the data.There was no significant difference between the flexural strengths/elastic modulus of the 0-5 wt.% nano β-TCP groups (p>0.05. The average flexural strength/elastic modulus of the prepared fissure sealant group (0% was significantly higher than the commercial fissure sealant group (Clinpro (p0.05. Examining the samples under SEM showed a significant increase in thickness of the intermediate layer with increasing concentrations of β-TCP nanoparticles (p<0.05.Addition of 1-5 wt.% β-TCP nanoparticles to the fissure sealants significantly increased the remineralization potential without affecting the mechanical properties.

  12. Safety and usability of hemostats, sealants, and adhesives.

    Science.gov (United States)

    Burks, Sandra; Spotnitz, William

    2014-08-01

    Hemostats, sealants, and adhesives are an integral part of surgical patient care. Nurses who have knowledge about these agents can better help ensure safe, efficient surgical patient care. As a caregiver and patient advocate, the perioperative nurse must understand the most current information about these agents and be prepared to facilitate the transfer of this knowledge to all caregivers. Information about these agents, including the contraindications, warnings, and precautions associated with their use as well as their preparation and application, is provided here. Algorithms designed to clarify the best options for using hemostats, sealants, and adhesives are included as well. Copyright © 2014 AORN, Inc. Published by Elsevier Inc. All rights reserved.

  13. [Eosinophilic pleural effusion possibly induced by fibrin sealant].

    Science.gov (United States)

    Kambayashi, Takatoyo; Suzuki, Takashi

    2012-02-01

    A 74-year-old man underwent right upper lobectomy for the lung cancer and bullectomy of right lower lobe. Fibrin sealant was used for sealing the excision line. The increase of the pleural effusion with increasing C-reactive protein( CRP) and eosinophilia was noted at the 17th day after the operation. The pleural effusion was transparent and yellowish colored suggesting transudatory liquid. The eosinophil in the pleural effusion was as high as 14%. The drainage of the pleural effusion was performed for 2 days resulting in disappearing the abnormal accumulation without any additional treatment. The cause of pleural effusion was supposed to be fibrin sealant by a positive result of the drug lymphocyte stimulation test.

  14. Clinical and SEM assessment of ART high-viscosity glass-ionomer sealants after 8-13 years in 4 teeth.

    NARCIS (Netherlands)

    Frencken, J.E.F.M.; Wolke, J.G.C.

    2010-01-01

    OBJECTIVES: Resin composite sealants are retained longer than low-viscosity glass-ionomer sealants. Nevertheless, a systematic review showed that there is no evidence that resin composite sealants are superior to low-viscosity glass-ionomers in preventing dentine carious lesion development. This

  15. Causes of poor sealant performance in soil-gas-resistant foundations

    International Nuclear Information System (INIS)

    Scott, A.

    1994-01-01

    Sealants for radon-resistant foundation construction must seal the gap between concrete sections. Modern sealants have such low permeability that seal performance depends only on the permeability of the material that contacts the sealant. The surface permeability of concrete walls and floors was measured by a specially designed permeameter, which measures the airflow induced by a pressure difference across a temporary test seal applied to the surface. The permeability of bulk concrete is about 10 -15 m 2 . Areas free of surface defects had surface permeability ranging from 10 -14 to 10 -16 m 2 . However, surface defects are common on concrete wall surfaces, which increase the permeability to >10 -12 m 2 , too high for standard seal designs to be adequate as the only method of soil gas and radon exclusion. Radon-resistant seals require either extended contact widths or mechanical removal of the surface layer and defects. (au) (4 refs.)

  16. Bisphenol A in dental sealants and its estrogen like effect

    Directory of Open Access Journals (Sweden)

    Manu Rathee

    2012-01-01

    Full Text Available Bisphenol A or BPA-based epoxy resins are widely used in the manufacture of commercial products, including dental resins, polycarbonate plastics, and the inner coating of food cans. BPA is a precursor to the resin monomer Bis-GMA. During the manufacturing process of Bis-GMA dental sealants, Bisphenol A (BPA might be present as an impurity or as a degradation product of Bis-DMA through esterases present in saliva. Leaching of these monomers from resins can occur during the initial setting period and in conjunction with fluid sorption and desorption over time and this chemical leach from dental sealants may be bioactive. Researchers found an estrogenic effect with BPA, Bis-DMA, and Bis-GMA because BPA lacks structural specificity as a natural ligand to the estrogen receptor. It generated considerable concern regarding the safety of dental resin materials. This review focuses on the BPA in dental sealants and its estrogen-like effect.

  17. Low-cost glass ionomer cement as ART sealant in permanent molars: a randomized clinical trial

    Directory of Open Access Journals (Sweden)

    Daniela HESSE

    2015-01-01

    Full Text Available Clinical trials are normally performed with well-known brands of glass ionomer cement (GIC, but the cost of these materials is high for public healthcare in less-affluent communities. Given the need to research cheaper materials, it seems pertinent to investigate the retention rate of a low-cost GIC applied as atraumatic restorative treatment (ART sealants in two centers in Brazil. Four hundred and thirty-seven 6-to-8-year-old schoolchildren were selected in two cities in Brazil. The children were randomly divided into two groups, according to the tested GIC applied in the first permanent molars. The retention rate was evaluated after 3, 6 and 12 months. Kaplan-Meier survival analysis and the log-rank test were performed. The variables were tested for association with sealant longevity, using logistic regression analyses (α = 5%. The retention rate of sealants after 12 months was 19.1%. The high-cost GIC brand presented a 2-fold-more-likely-to-survive rate than the low-cost brand (p < 0.001. Significant difference was also found between the cities where the treatments were performed, in that Barueri presented a higher sealant survival rate than Recife (p < 0.001. The retention rate of a low-cost GIC sealant brand was markedly lower than that of a well-known GIC sealant brand.

  18. Hemostats, sealants, and adhesives: components of the surgical toolbox.

    Science.gov (United States)

    Spotnitz, William D; Burks, Sandra

    2008-07-01

    The surgical toolbox is expanding, and newer products are being developed to improve results. Reducing blood loss so that bloodless surgery can be performed may help minimize morbidity and length of stay. As patients, hospital administrators, and government regulators desire less invasive procedures, the surgical technical challenge is increasing. More operations are being performed through minimally invasive incisions with laparoscopic, endoscopic, and robotic approaches. In this setting, tools that can reduce bleeding by causing blood to clot, sealing vessels, or gluing tissues are gaining an increasing importance. Thus, hemostats, sealants, and adhesives are becoming a more important element of surgical practice. This review is designed to facilitate the reader's basic knowledge of these tools so that informed choices are made for controlling bleeding in specific clinical situations. Such information is useful for all members of the operative team. The team includes surgeons, anesthesiologists, residents, and nurses as well as hematologists and other medical specialists who may be involved in the perioperative care of surgical patients. An understanding of these therapeutic options may also be helpful to the transfusion service. In some cases, these materials may be stored in the blood bank, and their appropriate use may reduce demand for other transfusion components. The product classification used in this review includes hemostats as represented by product categories that include mechanical agents, active agents, flowables, and fibrin sealants; sealants as represented by fibrin sealants and polyethylene glycol hydrogels; and adhesives as represented by cyanoacrylates and albumin cross-linked with glutaraldehyde. Only those agents approved by the Food and Drug Administration (FDA) and presently available (February 2008) for sale in the United States are discussed in this review.

  19. Percutaneous treatment of femoral pseudoaneurysms: comparison of fibrin sealant against thrombin

    Directory of Open Access Journals (Sweden)

    Daniel Mendes Pinto

    2013-12-01

    Full Text Available INTRODUCTION: Femoral pseudoaneurysms are a complication that occurs in connection with up to 8% of percutaneous procedures. Of the available treatments, ultrasound guided thrombin injection has a high success rate and is well-tolerated by patients. The combination of thrombin and fibrinogen known as fibrin sealant forms a stable clot and can be used to treat pseudoaneurysms, particularly those with complex anatomy and larger size. OBJECTIVE: To compare the results of treating femoral pseudoaneurysm in two ways: Group T was treated with thrombin alone and Group T+F was treated with fibrin sealant (thrombin+fibrinogen. METHODS: A retrospective analysis was conducted of femoral pseudoaneurysm cases treated between January 2005 and December 2012. RESULTS: Twenty-eight patients were treated, 21 with thrombin alone and seven with fibrin sealant. All patients in group T were treated successfully, but only four patients in group T+F were treated successfully (57.1% success rate in Group T+F, p<0.01. The three cases of failure in group T+F needed surgery and in one of these cases the complication was embolization to the femoral bifurcation. The pseudoaneurysms that were treated with fibrin sealant were larger (25 cm3 in Group T and 57.7 cm3 in Group T+F, p=0.02 and required larger volumes of thrombin (0.5 mL in Group T and 1.0 mL in Group T+F, p<0.01. There was one complication in Group T and two complications in Group T+F (p<0.01. CONCLUSIONS: Irrespective of the small number of cases reviewed, treatment with thrombin alone was superior to treating with fibrin sealant, since it caused few complications and was more effective at correcting pseudoaneurysms.

  20. A Trajectory Generation Method Based on Edge Detection for Auto-Sealant Cartesian Robot

    Directory of Open Access Journals (Sweden)

    Eka Samsul Maarif

    2014-07-01

    Full Text Available This paper presents algorithm ingenerating trajectory for sealant process using captured image. Cartesian robot as auto-sealant in manufacturing process has increased productivity, reduces human error and saves time. But, different sealant path in many engine models means not only different trajectory but also different program. Therefore robot with detection ability to generate its own trajectory is needed. This paper describes best lighting technique in capturing image and applies edge detection in trajectory generation as the solution. The algorithm comprises image capturing, Canny edge detection, integral projection in localizing outer most edge, scanning coordinates, and generating vector direction codes. The experiment results show that the best technique is diffuse lighting at 10 Cd. The developed method gives connected point to point trajectory which forms sealant path with a point to next point distance is equal to 90° motor rotation. Directional movement for point to point trajectory is controlled by generated codes which are ready to be sent by serial communication to robot controller as instruction for motors which actuate axes X and Y directions.

  1. An accelerated exposure and testing apparatus for building joint sealants.

    Science.gov (United States)

    White, C C; Hunston, D L; Tan, K T; Hettenhouser, J; Garver, J D

    2013-09-01

    The design, fabrication, and implementation of a computer-controlled exposure and testing apparatus for building joint sealants are described in this paper. This apparatus is unique in its ability to independently control and monitor temperature, relative humidity, ultraviolet (UV) radiation, and mechanical deformation. Each of these environmental factors can be controlled precisely over a wide range of conditions during periods of a month or more. Moreover, as controlled mechanical deformations can be generated, in situ mechanical characterization tests can be performed without removing specimens from the chamber. Temperature and humidity were controlled during our experiments via a precision temperature regulator and proportional mixing of dry and moisture-saturated air; while highly uniform UV radiation was attained by attaching the chamber to an integrating sphere-based radiation source. A computer-controlled stepper motor and a transmission system were used to provide precise movement control. The reliability and effectiveness of the apparatus were demonstrated on a model sealant material. The results clearly show that this apparatus provides an excellent platform to study the long-term durability of building joint sealants.

  2. Effectiveness of a new gelatin sealant system for dural closure.

    Science.gov (United States)

    Kawai, Hisashi; Nakagawa, Ichiro; Nishimura, Fumihiko; Motoyama, Yasushi; Park, Young-Su; Nakamura, Mitsutoshi; Nakase, Hiroyuki; Suzuki, Shuko; Ikada, Yoshito

    2014-10-01

    Watertight dural closure is imperative after neurosurgical procedures because inadequately treated leakage of cerebrospinal fluid (CSF) can have serious consequences. In this study, the authors test the use of a new gelatin glue as a dural sealant in in vitro and in vivo canine models of transdural CSF leakage. The in vitro model was sutured semicircles of canine dura mater and artificial dural substitute. The sutures were sealed with gelatin glue (n  =  20), fibrin glue (n  =  20), or a polyethylene glycol (PEG)-based hydrogel sealant (n  =  20). Each sample was set in a device to measure water pressure, and pressure was increased until leakage occurred. Bonding strength was subjectively evaluated. The in vivo model was dogs who underwent dural excision and received either no sealant (control group; n  =  5) or gelatin glue sealant (n  =  5) before dural closure. Twenty-eight days post-surgery, the maximum intracranial pressure was measured at the cisterna magna using Valsalva maneuver and tissue adhesion was evaluated. The water pressure at which leakage occurred in the in vitro model was higher with gelatin glue (76·5 ± 39·8 mmHg) than with fibrin glue (38·3 ± 27·4 mmHg, P control group (13·8 ± 4·0 mmHg, P control group (P  =  0·005). The new gelatin glue provides an effective watertight closure when used as an adjunct to sutured dural repair.

  3. Comparative efficacy of nanofilled and microfilled resin-modified glass ionomer as pits and fissure sealant in permanent molar teeth

    Directory of Open Access Journals (Sweden)

    Manzuma Akhter Zakaria

    2017-05-01

    Full Text Available The purpose of the present study was to compare the efficacy of nanofilled and microfilled resin- modified glass ionomer as pits and fissure sealants in permanent molar teeth. Ninety six teeth having fissure at the occlusal surface were randomly divided into two groups: Group I: Treated by nanofilled resin-modified glass ionomer sealant and Group II: Treated by microfilled resin- modified glass ionomer sealants. Clinical assessment was performed by modified Ryge´s criteria by means of retention, color match, marginal adaptation at 3, 6, and 12 months follow-up visit. Chi-square test was used for testing differences between the two groups; a value of p<0.05 was considered as statistically significant. The results revealed that at 12 months observation period, nanofilled resin-modified glass ionomer sealant showed better retention, color stability and marginal adaptation than that of microfilled resin-modified glass ionomer sealants. Furthermore, the differences between two groups in respect to marginal adaptation and color match were statistically significant (p<0.05. It can be concluded that nanofilled resin-modified glass ionomer sealant could be a better alternative to microfilled resin- modified glass ionomer sealant.

  4. Microleakage assessment of fissure sealant following fissurotomy bur or pumice prophylaxis use before etching

    Directory of Open Access Journals (Sweden)

    Ali Bagherian

    2013-01-01

    The aim of this investigation was to compare the microleakage level of fissure sealants prepared by a fissurotomy bur or pumice prophylaxis prior to acid etching. Materials and Methods: Ninety freshly extracted healthy maxillary premolar teeth were randomly selected for this investigation. Teeth were then divided into three fissure sealant preparatory groups of A: Fissurotomy bur + acid etch; B: Pumice prophylaxis + acid etch and C: Acid etch alone. Sealant was applied to the occlusal fissures of all specimens using a plastic instrument. This was to avoid any air trap under the sealant. Sample teeth were first thermocycled (1000 cycles, 20 s dwell time and then coated with two layers of nail varnish leaving 2 mm around the sealant. This was then followed by immersion in basic fuchsin 3%. Processed teeth were sectioned longitudinally and examined under a stereomicroscope for microleakage assessment using a score of 0-3. Collected data was then subjected to Kruskall-Wallis Analysis of Variance and Mann-Whitney U-test. P < 0.05 was considered as significant. Results: Teeth in fissurotomy bur and pumice prophylaxis groups had significantly reduced level of microleakage than those in acid etch alone (P = 0.005 and P = 0.003, respectively. Conclusion: Use of fissurotomy bur and pumice prophylaxis accompanied with acid etching appears to have a more successful reduction of microleakage than acid etch alone.

  5. Retention of fissure sealants using two different methods of application in teeth with hypomineralised molars (MIH): a 4 year clinical study.

    Science.gov (United States)

    Lygidakis, N A; Dimou, G; Stamataki, E

    2009-12-01

    This was to evaluate the retention rate of fissure sealants applied to MIH molars with occlusal enamel opacities, using two different application methods after 4 years. 54 children exhibiting molars with MIH aged 6-7 years, participated in the study. presence of at least 2 fully erupted caries-free maxillary or mandibular first permanent molars in the opposite sides of the mouth, both with occlusal enamel opacities without breakdown. Following parental consent, sealants were applied using a half-mouth experimental design. Group A: On a randomly assigned first molar on one side of the mouth sealants Fissurit were placed using a single bottle adhesive system (One-step prior to sealant application. Group B: Sealants were applied on the contra-lateral molar using the conventional etch and seal technique. Children were seen biannually when a preventive program was applied, without replacing any lost sealant. After 4 years, 47 sets of molars (94 teeth) were available for blind evaluation. Teeth in Group A presented a better retention rate; 70.2% were fully sealed, 29.7% partly sealed and none unsealed (lost sealant). Group B revealed 25.5% fully sealed, 44.6% partly sealed and 29.7% unsealed teeth. Differences between groups A and B were statistically significant (p0.01). In hypomineralised molars with occlusal opacities sealants appear to have greater retention when applied using 5th generation adhesive systems prior to sealant.

  6. Bond Strength of a Bisphenol-A-Free Fissure Sealant With and Without Adhesive Layer under Conditions of Saliva Contamination.

    Science.gov (United States)

    Mesquita-Guimarães, Késsia Suênia Fidelis de; Sabbatini, Iliana Ferraz; Almeida, Cintia Guimarães de; Galo, Rodrigo; Nelson-Filho, Paulo; Borsatto, Maria Cristina

    2016-01-01

    Dental sealants are important for prevention of carious lesions, if they have good shear strength. The aim of this study was to evaluate the shear bond strength (SBS) of two sealants to saliva-contaminated and non-contaminated enamel with and without an intermediate adhesive layer underneath the sealant. Ninety flat enamel surfaces from human third molars were randomly assigned to 6 groups (n=15): F (control): Fluroshield(tm) sealant; EWB (control): Embrace(tm) WetBond(tm); SB/F: Single Bond adhesive system + F; SB/EWB, s-SB/F and s-SB/EWB. In the s-SB/F and s-SB/EWB groups, the acid-etched enamel was contaminated with 0.01 mL of fresh human saliva for 20 s. Sealant cylinders were bonded to enamel surface with and without an intermediate adhesive system layer. The shear tests were performed using a universal testing machine (0.5 mm/min). Data were analyzed statistically by Kruskal-Wallis and Mann-Whitney tests (α=0.05). F presented higher mean SBS than EWB in all experimental conditions. The lowest SBS mean was obtained for EWB on contaminated enamel (p<0.05). In conclusion, an adhesive system layer should be used prior to sealant placement, in both dry and saliva-contaminated enamel. F had the best performance in all experimental conditions. EWB sealant showed very low results, but an adhesive layer underneath the sealant increased its SBS even after salivary contamination.

  7. Use of fibrin sealants for the localized, controlled release of cefazolin

    Science.gov (United States)

    Tredwell, Stephen; Jackson, John K.; Hamilton, Donald; Lee, Vivian; Burt, Helen M.

    2006-01-01

    Background Fibrin sealants are used increasingly in surgery to reduce bleeding and improve wound healing. They have great potential as biocompatible, biodegradable drug delivery systems, because the sealant may adhere to the target tissue and allow controlled release of the drug over an extended period. We investigated the encapsulation, stability and controlled release of erythromycin and cefazolin from Beriplast fibrin sealants (Aventis Behring Canada). Methods Drug-loaded clots were cast in glass vials and allowed to set. We observed the clots for drug precipitation and aggregation, and we assessed the effect of drug encapsulation on clot strength. Drug stability and release from the clots in phosphate buffered saline (PBS) was quantified by ultraviolet and visible violet absorbance spectroscopy and high-performance liquid chromatography. Results Erythromycin was found to release slowly from the fibrin clots over the first 2 hours but then degrade rapidly. Cefazolin was found to be very stable in clots in PBS (97% stable at 2 d and 93% stable at 5 d). The drug released in a controlled manner over 2 days, with most being released during the first day. The dose of drug released could be varied by changing the amount placed in the thrombin solution. Clot thickness had no effect on the rate of cefazolin release. Conclusion Overall, the 2-day release profile and the excellent stability of the drug suggest that cefazolin-loaded fibrin sealants may offer an effective route of postoperative antibiotic delivery. PMID:17152573

  8. Comparison of a plasma-based composite biologic sealant with fibrin glue (Tisseel) for vascular anastomoses.

    Science.gov (United States)

    Doillon, Charles J; Dion, Yves-Marie

    2004-12-01

    Biologic sealants are needed in numerous, more and more demanding, procedures--especially with developments occurring in endovascular and laparoscopic vascular techniques. An initial pilot study in dogs showed that a 4-cm aortotomy closed with a polyester patch sutured in place by a 4-mm-spaced running suture consistently led to massive hemorrhage. We then designed a study using five dogs where two aortotomies were done to compare the effect of Tisseel to that of an autologous sealant prepared in our laboratory. Arterial pressures and heparinization were maintained throughout the surgical procedure. Both biologic sealants prevented hemorrhage from the arteriotomy at unclamping. Macroscopic and histologic assessments were performed. At killing, one week later, the autologous sealant exhibited less blood saturation of the collagen sponge compared with Tisseel. The use of autologous plasma combined with other adhesive components could be an efficient alternative to allogenic fibrin glue. Further studies are needed to confirm these observations.

  9. 76 FR 79537 - Approval and Promulgation of Air Quality Implementation Plans; Delaware; Adhesives and Sealants Rule

    Science.gov (United States)

    2011-12-22

    ... Promulgation of Air Quality Implementation Plans; Delaware; Adhesives and Sealants Rule AGENCY: Environmental..., sale, use, or application of adhesives, sealants, primers, and solvents. EPA is approving this SIP... miscellaneous industrial adhesives control techniques guideline (CTG) category in accordance with the...

  10. ART restorations and sealants placed in Chinese school children--results after three years.

    Science.gov (United States)

    Holmgren, C J; Lo, E C; Hu, D; Wan, H

    2000-08-01

    These were to assess whether ART restorations and sealants could be provided to children in a school environment in China, to assess patient acceptability of the ART approach, and to evaluate on a longitudinal basis the treatments performed. This study was conducted in Deyang, Sichuan Province, in western China. A total of 294 ART restorations were placed in 197 children and 191 fissure sealants were placed in 140 children by five middle-level dentists in four secondary schools. Standard instruments and procedures for ART were used. The restorative material used was a high-strength glass-ionomer (Ketac-Molar, ESPE). The treatments were evaluated annually after placement by the same examiner who had not been involved in the placement of the restorations nor sealants using explorers and mouth-mirrors. At the 3-year examination an independent external examiner evaluated the restorations using USPHS criteria. Most of the children did not report discomfort during treatment and 92% were willing to receive ART restorations again. The cumulative 1-year and 3-year survival rates of small Class I restorations were 99% and 92% respectively. The corresponding figures for large Class I restorations were 90% and 77%. After 3 years, 72% of the sealants were either partially or completely retained. Only 2% of the sealed teeth developed fissure caries and these involved teeth where the sealants had been lost. Similar success rates were found using USPHS criteria. The ART approach for preventing and treating tooth decay in Chinese school children was shown to be appropriate, effective and acceptable. The 3-year survival rates of the restorations were high but were related to the size and type of the restoration.

  11. Polychlorinated biphenyls in polysulfide sealants-Occurrence and emission from a landfill station

    International Nuclear Information System (INIS)

    Persson, N. Johan; Pettersen, Harald; Ishaq, Rasha; Axelman, Johan; Bandh, Cecilia; Broman, Dag; Zebuehr, Yngve; Hammar, Tommy

    2005-01-01

    Approximately 80 000 kg polysulfide sealant containing 10 000-18 000 kg polychlorinated biphenyls (PCB) was deposited at a Swedish municipal landfill station during 1965-1973. Investigations during 1994 showed that soil layers underneath the landfill had concentration of PCB not alarmingly high. The concentration of PCB congeners in ground water samples was elevated 4-750 times compared to a reference sample. Based on samples of ground water, leachate water, and flux chambers measuring evaporation of PCB from the landfill surface, the emission of PCB was estimated to be 1 g ΣPCB/yr. This very low rate was attributed to the high sorptive capacity of the sealant. Compared to a reference site, the evaporation flux was elevated for the most volatile congeners, but factors 20-1400 lower than from another landfill which was contaminated with PCB in paper-pulp fibres. - From a municipal 2-ha landfill containing 10-18 tonnes of ΣPCB bound in polysulfide sealants, only 1 g per year escape to the surroundings

  12. Comparison of commercial fibrin sealants in facelift surgery: a prospective study

    Directory of Open Access Journals (Sweden)

    Botti G

    2013-11-01

    Full Text Available Giovanni Botti,1 Michele Pascali,2 Chiara Botti,1 Florian Bodog,3 Pietro Gentile,2 Valerio Cervelli2 1Villa Bella Clinic, Salò, 2Department of Plastic and Reconstructive Surgery, University of Rome Tor Vergata, Italy; 3University of Oradea, Oradea, Romania Background: The aim of this study was to compare the effects of two types of fibrin glue in patients undergoing facelift surgery. Methods: A prospective, controlled "right-left side" study was carried out in 20 patients. The two fibrin sealants used were Quixil® and Tissucol®. The two sealants were used at the same time, ie, one on one side of the face and the other on the contralateral side. Comparisons were made with regard to rates of hematoma and seroma, degree of induration, edema, ecchymosis, pain levels, and patient satisfaction. Results: The results were almost equivalent. The only exception was a significant (40 mL hematoma in a patient treated with Quixil. Bleeding was most likely due to a sudden rise in blood pressure during the immediate postoperative period. However, it must be emphasized that, while Tissucol actually seals the undermined area, thus virtually eliminating the dead space, Quixil acts differently, in that its effectiveness in preventing hematoma is linked mainly to its hemostatic effect. Conclusion: The two fibrin sealants used were nearly identical with regard to patient safety and quality of the result. Nevertheless, it is noted that, while Tissucol has both hemostatic and "gluing" effects, Quixil is mainly effective in securing hemostasis. Keywords: facelift surgery, rhytidectomy, fibrin sealants, hematoma

  13. Leak tight sealants and joint details for concrete structure in RAPP

    International Nuclear Information System (INIS)

    Singha Roy, P.K.; Baste, M.S.

    1975-01-01

    Leak tightness may pertain to either air or water and in extreme cases each will require separate consideration based on general basic requirements. Leak-tight sealants against air pressure are required in the construction joints and around penetrations in the concrete containment structures. The containment structures should be able to withstand the maximum anticipated design pressure during the incident of a MCA with only minimal leakage (0.1% of bldg. volume per day in RAPP) which is mostly through these joints. Apart from proper joint design and preparation the sealant itself must have superb adhesion to the concrete surface and integrify throughout its service life to prevent any rupture or micro-cracks at any section of the joint. Leak tightness pertains to water tightness as well. A critical water-tight joint at the bottom dome of the prestressed concrete dousing tank at its junction with the 36 inches dia dousing water pipes constructed in RAPP-2, which should be able to withstand the water pressure, continuous submergence in the water of the tank and the longitudinal and lateral movement of the water pipes during opening and closure of the dousing valves, has been made and hydrostatically tested when not even the slight sweating was found. The construction and materials of the above joints and the sealant along with the properties and performance observed during testing/use are described. As the sealant used is an imported poly-sulphide caulking compound suggestions have also been made, which may be kept in mind while developing an Indian substitute. (author)

  14. 76 FR 64237 - Approval and Promulgation of Air Quality Implementation Plans; Maryland; Adhesives and Sealants Rule

    Science.gov (United States)

    2011-10-18

    ...-9480-5] Approval and Promulgation of Air Quality Implementation Plans; Maryland; Adhesives and Sealants... chemical production and polytetrafluoroethylene operations; from paint, resin, and adhesive manufacturing; and from adhesive and sealant application. This SIP revision also pertains to an addition of a new...

  15. A reversible thermoresponsive sealant for temporary closure of ocular trauma.

    Science.gov (United States)

    Bayat, Niki; Zhang, Yi; Falabella, Paulo; Menefee, Roby; Whalen, John J; Humayun, Mark S; Thompson, Mark E

    2017-12-06

    Open globe injuries are full-thickness injuries sustained to the eye wall (cornea or sclera), which cause immediate drops in intraocular pressure that may lead to retinal detachment and permanent vision loss if not treated rapidly after injury. The current standard of care for open globe injuries consists of suturing the margins closed, but the technique can be time-consuming, requires specialized training and equipment, and can lead to patient discomfort, abrasion, and infection from eye rubbing. We engineered an injectable, thermoresponsive sealant (TRS) and a custom tool to occlude open globe injuries. The smart hydrogel sealant consists of physically cross-linked N -isopropylacrylamide copolymerized with butylacrylate. At low temperatures, it can be injected as a liquid, and when raised to body temperature, a heat-induced gelation converts the hydrogel into a solidified occlusion. The sealant can be repositioned or removed without causing additional trauma via exposure to cold water. In vitro and ex vivo assessments of mechanical adhesion to eye tissue revealed maintenance of intraocular pressure that is five times greater than the physiological range with reversible seal strength comparable to cyanoacrylate (super glue). In vivo assessment in a rabbit model of ocular trauma demonstrated ease of use for TRS deployment, statistically significant improvement in wound sealing, and no evidence of neurotoxicity, retinal tissue degradation, or significant chronic inflammatory response after 30 days of exposure. Given the advantages of body heat-induced gelation, rapid reversible occlusion, and in vivo safety and efficacy, shape-adaptable TRSs have translational potential as smart wound sealants for temporary occlusion of surgical incisions or traumatic injuries. Copyright © 2017 The Authors, some rights reserved; exclusive licensee American Association for the Advancement of Science. No claim to original U.S. Government Works.

  16. Polychlorinated biphenyls (PCBs) in indoor air originating from sealants in contaminated and uncontaminated apartments within the same housing estate

    DEFF Research Database (Denmark)

    Frederiksen, Marie; Meyer, Harald William; Ebbehøj, Niels Erik

    2012-01-01

    . The PCB(tot) levels in the air of the contaminated section were 168-3843 ng m(-3) (mean: 1030 ng m(-3)), while the mean levels in the reference apartments were 6.03 ng m(-3). The sum of the 24 measured PCB congeners in sealants from the contaminated section was 187-221680 mg kg(-1). Principal component......Twenty-four congeners of polychlorinated biphenyls (PCBs) were measured in 83 air samples and 20 elastic sealants samples of apartments with PCB-containing sealants. In addition, PCBs were measured in 21 air samples from reference apartments located in an uncontaminated section of the same estate...... analysis revealed four groups among the sealant samples with different congener compositions, only two of which were clearly similar to known PCB mixtures, while two were not. Significant correlations and intercorrelations were observed between the lower chlorinated congeners in air and sealant, e...

  17. Fibrin sealant for mesh fixation in laparoscopic groin hernia repair does not increase long-term recurrence

    DEFF Research Database (Denmark)

    Fenger, Andreas Qwist; Helvind, Neel Maria; Pommergaard, Hans-Christian

    2016-01-01

    BACKGROUND: Methods of groin hernia repair include laparoscopic techniques using tissue-penetrating mesh fixation or non-penetrating fixation. Concerns regarding hernia repair include postoperative chronic pain, sexual dysfunction, and recurrence. Earlier estimations of recurrence rates have......) laparoscopic groin hernia repair using either fibrin sealant or tacks for mesh fixation. METHODS: This study used data from the Danish Hernia Database to create the following cohort: All patients operated laparoscopically for primary groin hernia with a TAPP procedure using fibrin sealant for mesh fixation...... difference in long-term reoperation rates and clinical recurrences in patients undergoing TAPP repair with meshes fixated with fibrin sealant compared with tacks....

  18. Migration of PCBs from Sealants to Adjacent Material

    DEFF Research Database (Denmark)

    Andersen, Helle Vibeke; Gunnarsen, Lars Bo; Kampmann, Kristoffer

    2015-01-01

    PCB in sealants can migrate into porous surfaces like concrete and brick and contaminate these materials. The study focuses on an analysis of concentration profiles in relation to alleviation of PCB contamination. The PCB content was determined in 20 samples of concrete and 6 samples of brick adj...

  19. Clinical Evaluation of applying a hydrophobic and a hydrophilic bonding agent on the retention and durability of fissure sealant therapy

    Directory of Open Access Journals (Sweden)

    Mostafa GHandi

    2016-03-01

    Full Text Available Background and Aims: As in fissure sealant therapy the tooth surface is mostly enamel, the use of an enamel bonding agent (hydrophobic bonding agent may be more cost effective than that of newer generations of bonding (hydrophilic bonding agents. The aim of this study was to compare the retention and durability of fissure sealant therapy when applying an enamel bonding agent, a dentin bonding agent and no bonding agent during 4 years. Materials and Methods: This study was done on the first permanent molars of the upper and lower jaws of 24 students of the first grade of a primary school (6-7 years old. On 36 teeth, a dentin bonding agent (Excite was applied under the fissure sealant and on 36 teeth an enamel bonding agent (Margin bond was applied under the fissure sealant. Then, 24 teeth were selected from these two groups and were compared with a group (including 24 teeth with no bonding agent under the fissure sealant (as control group. All the fissures of the teeth were evaluated annually for 4 years to find out the presence or absence of fissure sealant substance. Data were analyzed using Wilcoxon test. Results: From the statistical analysis, there was no significant difference in retention and durability of the fissure sealant substance comparing the group with dentin bonding agent (Excite and the group with enamel bonding agent (Margin bond. Also, using a bonding agent made no significant difference (P>0.05. Conclusion: According to the results of this study, using a bonding agent made no improvement in the retention and durability of fissure sealant substance.

  20. Evaluation of a hydrophilic gingival dental sealant in beagle dogs.

    Science.gov (United States)

    Sitzman, Clarence

    2013-01-01

    A liquid solution, gingival sealant containing polymers that form a barrier film upon application was evaluated in dogs. It is a non-toxic, low viscosity, hydrophilic barrier sealant that dries in approximately 10 to 15-seconds after subgingival application. It was designed as a preventative to be applied immediately following a professional oral hygiene procedure in order to block plaque and calculus formation in the sulcus and aid in the prevention of periodontal disease in companion animals. Additionally, the polymer was designed to promote an aerobic environment in the sulcus by oxygen and water transport through engineered pores within the polymer. A 30-day split-mouth, blinded study in two groups of 15 beagle dogs was used. Plaque was significantly (p periodontal disease in dogs.

  1. Transcutaneous Drainage of Gel-Like Substance after Application of Hydrogel Dural Sealant: Report of Two Cases.

    Science.gov (United States)

    Siman, Homayoun; Techy, Fernando

    2016-02-01

    Study Design Case report. Objective Incidental durotomy (IDT) is a common complication of spinal surgery. The use of collagen matrix graft along with hydrogel dural sealant is a common method of IDT repair. With this method, there have been several reported cases of detrimental dural sealant expansion in the literature. One case study reported an expansion rate greater than 300%; many report neurologic damage. This article reports the clinical course of two patients who developed postoperative transcutaneous drainage of a gel-like substance after the use of a dural sealant, which is a previously unreported complication. Methods The clinical course and treatment outcome of two patients is presented. Results Both patients experienced postoperative transcutaneous drainage of a gel-like substance at the surgical site. Case one began draining this substance on postoperative day 14. This patient required no further intervention, and the drainage ended after 3 mL of a gel-like substance was expressed from his incision while in the clinic. Case two began draining the gel on postoperative day 16. This patient underwent two washout procedures and resolution of the drainage. No infection was ever detected. Conclusions To our knowledge, our patients are the first reported cases of transcutaneous drainage of expanded dural sealant. It is important to take into consideration the unexpected expansion of a dural sealant when using it for the repair of IDT.

  2. Sealing effectiveness of fissure sealant bonded with universal adhesive systems on saliva-contaminated and noncontaminated enamel.

    Science.gov (United States)

    Memarpour, Mahtab; Shafiei, Fereshteh; Zarean, Mehran; Razmjoei, Faranak

    2018-01-01

    The effectiveness of sealants is dependent upon their adhesion to enamel surface. The aim of the study was to evaluate the sealing ability of a pit and fissure sealant used with a universal adhesive (etch-and-rinse vs. self-etch modes) when the site is contaminated with saliva. Adhesive properties were evaluated as microleakage and scanning electron microscopic (SEM) characteristics. A total of 72 mandibular third molars were randomly divided into 6 groups (n=12). Occlusal pits and fissures were sealed with an unfilled resin fissure sealant (FS) material with or without saliva contamination. The groups included: 1) phosphoric acid etching + FS (control), 2) phosphoric acid etching + Scotchbond Universal (etch-and-rinse) + FS, 3) phosphoric acid etching + saliva + Scotchbond Universal (etch-and-rinse) + FS, 4) Scotchbond Universal (self-etching) + FS,5) Scotchbond Universal (self-etching) + saliva + FS, and 6) Scotchbond Universal (self-etching) + saliva + Scotchbond Universal + FS. After thermocycling, the teeth were placed in 0.5% fuchsin, sectioned, and evaluated by digital microscopy. Two samples from each group were also observed by SEM. The data were analyzed with Kruskal-Wallis and Mann-Whitney tests for a significance of p universal adhesive in etch-and-rinse or self-etch modes was similar to that of conventional acid etching. Saliva contamination had a negative effect on sealant adhesion to pretreated enamel. Key words: Pit and fissure sealant, Universal adhesive, Saliva.

  3. Dental Sealants: Knowledge, Value, Opinion, and Practice among Dental Professionals of Bathinda City, India

    OpenAIRE

    Asawa, Kailash; Gupta, Vivek V.; Tak, Mridula; Nagarajappa, Ramesh; Chaturvedi, Pulkit; Bapat, Salil; Mishra, Prashant; Roy, Santanu Sen

    2014-01-01

    Objective. The purpose of the study was to assess the knowledge, value, opinion, and practice regarding use of dental sealants among private dental practitioners in Bathinda City, Punjab, India. Materials and Methods. A cross-sectional survey was conducted among all private dental practitioners in Bathinda City, Punjab. A self-administered structured questionnaire consisting of 28 items was used to assess their knowledge, value, opinion, and practice regarding dental sealants. One-way analysi...

  4. A prospective randomized trial comparing homologous and autologous fibrin sealants for the control of alveolar air leak.

    Science.gov (United States)

    Kılıç, Burcu; Erşen, Ezel; Demirkaya, Ahmet; Kara, H Volkan; Alizade, Nurlan; İşcan, Mehlika; Kaynak, Kamil; Turna, Akif

    2017-09-01

    Postoperative air leak is a common complication seen after pulmonary resection. It is a significant reason of morbidity and also leads to greater hospital cost owing to prolonged length of stay. The purpose of this study is to compare homologous sealant with autologous one to prevent air leak following pulmonary resection. A total of 57 patients aged between 20 and 79 (mean age: 54.36) who underwent pulmonary resection other than pneumonectomy (lobar or sublobar resections) were analyzed. There were 47 males (83%) and 10 females (17%). Patients who intraoperatively had air leaks were randomized to receive homologous (Tisseel; n=28) or autologous (Vivostat; n=29) fibrin sealant. Differences among groups in terms of air leak, prolonged air leak, hospital stay, amount of air leak were analyzed. Indications for surgery were primary lung cancer in 42 patients (71.9%), secondary malignancy in 5 patients (8.8%), and benign disease in 10 patients (17.5%). Lobectomy was performed in 40 patients (70.2%), whereas 17 patients (29.8%) had wedge resection. Thirteen (46.4%) patients developed complications in patients receiving homologous sealant while 11 (38.0%) patients had complication in autologous sealant group (P=0.711). Median duration of air leak was 3 days in two groups. Time to intercostal drain removal was 3.39 and 3.38 days in homologous and autologous sealant group respectively (P=0.978). Mean hospital stay was 5.5 days in patients receiving homologous sealant whereas it was 5.0 days in patients who had autologous agent (P=0.140). There were no significant differences between groups in terms of measured maximum air leak (P=0.823) and mean air leak (P=0.186). There was no significant difference in the incidence of complications between two groups (P=0.711). Autologous and heterologous fibrin sealants are safe and acts similarly in terms of air leak and hospital stay in patients who had resectional surgery.

  5. Evaluating cyclic fatigue of sealants during outdoor testing

    Science.gov (United States)

    R. Sam Williams; Steven Lacher; Corey Halpin; Christopher White

    2009-01-01

    A computer-controlled test apparatus (CCTA) and other instrumentation for subjecting sealant specimens to cyclic fatigue during outdoor exposure was developed. The CCTA enables us to use weather-induced conditions to cyclic fatigue specimens and to conduct controlled tests in-situ during the outdoor exposure. Thermally induced dimensional changes of an aluminum bar...

  6. Subclinical and clinical mastitis in heifers following the use of a teat sealant precalving.

    Science.gov (United States)

    Parker, K I; Compton, C; Anniss, F M; Weir, A; Heuer, C; McDougall, S

    2007-01-01

    This study investigated the effect in heifers of infusion of a bismuth subnitrate teat-canal sealant and bacterial intramammary infection (IMI) precalving on prevalence of postcalving IMI and incidence of clinical mastitis in the first 2 wk postcalving. Glands (n = 1,020) from heifers (n = 255) in 5 seasonally calving, pasture-fed dairy herds were randomly assigned within heifer to 1 of 4 treatment groups (no treatment; mammary gland secretion collection; infusion of a teat sealant; or sample collection with infusion of teat sealant). Heifers within a herd were enrolled on one calendar day, 31 d on average before the planned start of the seasonal calving period. Duplicate milk samples were collected from each gland within 4 d after calving for bacterial culture. Herd owners collected duplicate milk samples, before treatment, for bacterial culture from glands they defined as having clinical mastitis. The gland prevalence of IMI precalving was 15.5% and did not differ between herds. Bacteria isolated precalving included coagulase-negative staphylococci (76.9% of all bacteriologically positive samples), Streptococcus uberis (14.1%), Staphylococcus aureus (5.1%), Corynebacterium spp. (3.8%), and others (0.1%). The presence of an IMI precalving increased the risk of an IMI postcalving 3.6-fold and the risk of clinical mastitis 4-fold, relative to no IMI precalving. Infusion of the teat sealant reduced the risk of postcalving IMI due to Strep. uberis by 84%, and of clinical mastitis by 68%. Sampling the glands precalving had no effect on postcalving IMI or on clinical mastitis incidence. Use of an internal teat canal sealant in heifers precalving may be a useful tool for reducing the risk of subclinical and clinical mastitis in heifers.

  7. In Vitro Comparison of Microleakage of Two Materials Used as Pit and Fissure Sealants

    Directory of Open Access Journals (Sweden)

    Zahra Bahrololoomi

    2011-09-01

    Full Text Available Background and aims. Marginal seal of the material is extremely important in fissure sealant therapy. The aim of this study was to investigate microleakage of flowable composite resins and conventional fissure sealants with or without dentin bonding agent. Materials and methods. The occlusal surface of 60 intact extracted human premolars, divided into four groups, were cleaned with pumice/slurry, etched with 37% phosphoric acid for 15 seconds, rinsed and dried. Groups were treated differently: Excite bonding agent followed by Helioseal F fissure sealant in group1; Helioseal F alone in group 2; Excite bonding agent followed by Tetric Flow in group 3; and Tetric Flow alone in group 4. Light-curing was done after each application. After thermocycling, the whole surface of each specimen was coated with nail varnish except for one millimeter around the fissure sealant. The teeth were immersed in 2% basic fuchsin for 24 hours and then sectioned buccolingually. The sections were analyzed for leakage under a stereomicroscope. Data was analyzed by Kruskal-Wallis and Mann-Whitney tests at a significance level of P 0.05, except for groups 2 and 4 (P = 0.002 and groups 3 and 4 (P = 0.033. Conclusion. Use of a flowable composite with bonding agent is a good alternative for sealing pits and fissures; however, further in vitro and in vivo studies are necessary.

  8. Caries-preventive effect of a one-time application of composite resin and glass ionomer sealants after 5 years.

    NARCIS (Netherlands)

    Beiruti, N.; Frencken, J.E.F.M.; Hof, M.A. van 't; Taifour, D.; Palenstein Helderman, W.H. van

    2006-01-01

    The aim of the present trial was to (1) compare the caries-preventive effect of glass ionomer sealants, placed according to the atraumatic restorative treatment (ART) procedure, with composite resin sealants over time and (2) investigate the caries-preventive effect after complete disappearance of

  9. Effect of enamel sealants on tooth bleaching and on the color stability of the result.

    Science.gov (United States)

    Corcodel, N; Hassel, A J; Sen, S; Saure, D; Rammelsberg, P; Lux, C J; Zingler, S

    2017-04-01

    The purpose of this in vitro study was to evaluate the effect of enamel sealants on bleaching of natural teeth by use of 40 % hydrogen peroxide in a dental surgery. The color stability of the results from bleaching was, furthermore, determined 10 months after the bleaching procedure. In a standardized setting, four sealants (Pro Seal ® , Light Bond™ Sealant, Protecto ® , and Clinpro™ XT Varnish) were applied to and removed from human teeth in accordance with the manufacturer's instructions. Natural teeth served as medium; half of the teeth were sealed and the others served as controls. Hydrogen peroxide gel (40 %; Opalescence Boost; Ultradent Products, South Jordan, UT, USA) was used as bleaching agent. Color measurement was performed with a spectroradiometer (Photoresearch PR670) before the bleaching process (T1) and 24 h (T2) and 10 months (T3) after bleaching. The spectroradiometer results were expressed by use of the Commission Internationale de l'Éclairage (CIE) L*a*b* color notation. The L*, a*, and b* values of the sealed and the unsealed surfaces were not significantly different at any time during the study (p > 0.05), irrespective of the sealant used. Ten months after the bleaching process, mean L*, a*, and b* values were lower than at 1-day post-bleaching; the mean value of ΔE between 1-day post-bleaching and 10 months post-bleaching was 2.46 (±3.1). The results of the study suggest that the effectiveness of professional tooth whitening is not appreciably affected by the application of the four sealants tested.

  10. Long-Standing Motor and Sensory Recovery following Acute Fibrin Sealant Based Neonatal Sciatic Nerve Repair

    Directory of Open Access Journals (Sweden)

    Natalia Perussi Biscola

    2016-01-01

    Full Text Available Brachial plexus lesion results in loss of motor and sensory function, being more harmful in the neonate. Therefore, this study evaluated neuroprotection and regeneration after neonatal peripheral nerve coaptation with fibrin sealant. Thus, P2 neonatal Lewis rats were divided into three groups: AX: sciatic nerve axotomy (SNA without treatment; AX+FS: SNA followed by end-to-end coaptation with fibrin sealant derived from snake venom; AX+CFS: SNA followed by end-to-end coaptation with commercial fibrin sealant. Results were analyzed 4, 8, and 12 weeks after lesion. Astrogliosis, microglial reaction, and synapse preservation were evaluated by immunohistochemistry. Neuronal survival, axonal regeneration, and ultrastructural changes at ventral spinal cord were also investigated. Sensory-motor recovery was behaviorally studied. Coaptation preserved synaptic covering on lesioned motoneurons and led to neuronal survival. Reactive gliosis and microglial reaction decreased in the same groups (AX+FS, AX+CFS at 4 weeks. Regarding axonal regeneration, coaptation allowed recovery of greater number of myelinated fibers, with improved morphometric parameters. Preservation of inhibitory synaptic terminals was accompanied by significant improvement in the motor as well as in the nociceptive recovery. Overall, the present data suggest that acute repair of neonatal peripheral nerves with fibrin sealant results in neuroprotection and regeneration of motor and sensory axons.

  11. In vitro study of Streptococcus mutans adhesion on composite resin coated with three surface sealants

    Directory of Open Access Journals (Sweden)

    Da Hye Kim

    2017-02-01

    Full Text Available Objectives Although the coating of surface sealants to dental composite resin may potentially reduce bacterial adhesion, there seems to be little information regarding this issue. This preliminary in vitro study investigated the adhesion of Streptococcus mutans (S. mutans on the dental composite resins coated with three commercial surface sealants. Materials and Methods Composite resin (Filtek Z250 discs (8 mm in diameter, 1 mm in thickness were fabricated in a mold covered with a Mylar strip (control. In group PoGo, the surfaces were polished with PoGo. In groups PS, OG, and FP, the surfaces polished with PoGo were coated with the corresponding surface sealants (PermaSeal, PS; OptiGuard, OG; Fortify Plus, FP. The surfaces of the materials and S. mutans cells were characterized by various methods. S. mutans adhesion to the surfaces was quantitatively evaluated using flow cytometry (n = 9. Results Group OG achieved the lowest water contact angle among all groups tested (p 0.05 or significantly lower (group OG, p < 0.001 bacterial adhesion when compared with the control group. Conclusions The application of the surface sealants significantly reduced S. mutans adhesion to the composite resin polished with the PoGo.

  12. Effect of occlusal calculus utilized as a potential "biological sealant" in special needs patients with gastric feeding tubes: a qualitative in vitro contrast to pit and fissure sealant restorations.

    Science.gov (United States)

    Owens, Barry M; Sharp, Harry K; Fourmy, Emily E; Phebus, Jeffrey G

    2016-01-01

    The aim of this case report and in vitro investigation was to evaluate the marginal microleakage of intact occlusal calculus of primary molars extracted from a special needs patient who received nutrition via a gastric feeding tube. An adolescent with a history of developmental disturbance presented for routine dental care in a hospital facility. Prophylaxis was performed, and 2 mandibular permanent molars were restored. Five primary molars were extracted due to mobility and delayed retention. Heavy deposits of intact calculus were present on the occlusal surfaces of the primary teeth. The extracted teeth were immersed in methylene blue dye solution, invested in acrylic resin, sectioned into blocks, and photographed at 20× and 40× magnification. Previously photographed calculus-free molars with pit and fissure sealants were reviewed and served as contrasting "restorations." The occlusal calculus on the primary teeth extracted from the patient absorbed the dye, while the comparison teeth containing pit and fissure sealants exhibited varying degrees of marginal dye penetration (microleakage). No marginal microleakage was noted in the calculus specimens, indicating that this substrate may serve as a "natural" occlusal surface sealant and that its removal from occlusal surfaces during routine oral prophylaxis may be unnecessary.

  13. Effectiveness of Dry Cow Therapy Comprising Antibiotic Treatment, Internal Teat Sealant, and α-Tocopherol Against New Intramammary Infections in Cows

    Directory of Open Access Journals (Sweden)

    Cengiz Mehmet

    2015-04-01

    Full Text Available The aim of this study was to evaluate the preventive effectiveness of dry cow therapy based on antibiotic, internal teat sealant, and α-tocopherol administered separately or in various combinations at drying-off The study was performed on 322 uninfected quarters of 95 cows originating from three dairy herds. The new intramammary infection rates after calving were measured to evaluate the effectiveness. The quarters were divided into six groups differing in treatment, namely: control group (group C, n = 40 and five treatment groups. Treatment groups were arranged as follows: group A (antibiotic alone, n = 81, group AS (antibiotic + sealant, n = 40, group AST (antibiotic + sealant + α-tocopherol, n = 40, group T (α-tocopherol alone, n = 40, group S (sealant alone, n = 81. New infection rate amounted to 47.5% in group C. The treatment in group AST significantly prevented from the occurrence of new intramammary infections (12.5%, P 0.05, although the use of the sealant alone (group S decreased the risk of new infection (24.7%, P 0.05. Increased α-tocopherol level (P < 0.05 was detected after calving in the quarters from cows that received α-tocopherol injections. In conclusion, the combination of antibiotic, internal teat sealant, and α-tocopherol used in dry cow therapy showed a significantly better preventive effect against new intramammary infections, than the therapeutics administered separately.

  14. Fissure sealant materials: Wear resistance of flowable composite resins.

    Science.gov (United States)

    Asefi, Sohrab; Eskandarion, Solmaz; Hamidiaval, Shadi

    2016-01-01

    Background. Wear resistance of pit and fissure sealant materials can influence their retention. Wear characteristics of sealant materials may determine scheduling of check-up visits. The aim of this study was to compare wear resistance of two flowable composite resins with that of posterior composite resin materials. Methods. Thirty-five disk-shaped specimens were prepared in 5 groups, including two flowable composite resins (Estelite Flow Quick and Estelite Flow Quick High Flow), Filtek P90 and Filtek P60 and Tetric N-Ceram. The disk-shaped samples were prepared in 25-mm diameter by packing them into a two-piece aluminum mold and then light-cured. All the specimens were polished for 1minute using 600-grit sand paper. The samples were stored in distilled water at room temperature for 1 week and then worn by two-body abrasion test using "pin-on-disk" method (with distilled water under a 15-Nload at 0.05 m/s, for a distance of 100 meter with Steatite ceramic balls antagonists). A Profilometer was used for evaluating the surface wear. Data were analyzed with the one-way ANOVA. Results. Estelite Flow Quick exhibited 2708.9 ± 578.1 μm(2) and Estelite Flow Quick High Flow exhibited 3206 ± 2445.1 μm(2)of wear but there were no significant differences between the groups. They demonstrated similar wear properties. Conclusion. Estelite flowable composite resins have wear resistance similar to nano- and micro-filled and micro-hybrid composite resins. Therefore, they can be recommended as pit and fissure sealant materials in the posterior region with appropriate mechanical characteristics.

  15. Engaging Stakeholders in Patient-Centered Outcomes Research Regarding School-Based Sealant Programs.

    Science.gov (United States)

    Chi, Donald L; Milgrom, Peter; Gillette, Jane

    2018-02-01

    Purpose: The purpose of this study was to use qualitative methods to describe the key lessons learned during the stakeholder engagement stage of planning a randomized clinical trial comparing outcomes of silver diamine fluoride (SDF) as an alternative to pit-and-fissure sealants in a school-based delivery system. Methods: Eighteen caregivers and community-based stakeholders with involvement in the school-based sealant program Sealants for Smiles from the state of Montana, were recruited for this qualitative study. United States (U.S.) Patient-Centered Outcomes Research Institute (PCORI) methodology standards were used to develop two semi-structured interview guides consisting of 6 questions. One interview guide was used for telephone interviews with caregivers and the second was used for a stakeholder focus group. Content analytic methods were used to analyze the data. Results: All participants believed that a study comparing SDF and sealants was clinically relevant. Non-caregiver stakeholders agreed with the proposed primary outcome of the study (caries prevention) whereas caregivers also emphasized the importance of child-centered outcomes such as minimizing dental anxiety associated with dental care. Stakeholders described potential concerns associated with SDF such as staining and perceptions of safety and discussed ways to address these concerns through community engagement, appropriate framing of the study, proper consent procedures, and ongoing safety monitoring during the trial. Finally, stakeholders suggested dissemination strategies such as direct communication of findings through professional organizations and encouraging insurance plans to incentivize SDF use by reimbursing dental providers. Conclusions: Involving key stakeholders in early planning is essential in developing patient-centered research questions, outcomes measures, study protocols, and dissemination plans for oral health research involving a school-based delivery system. Copyright © 2018

  16. Efficacy of fibrin-sealants in reducing biliary leakage following laparoscopic common bile duct exploration.

    Science.gov (United States)

    Parra-Membrives, Pablo; Martínez-Baena, Darío; Lorente-Herce, José Manuel; Martín-Balbuena, Ramón

    2018-05-21

    In spite of the acquired experience with laparoscopic common bile duct exploration (LCBDE) for choledocholithiasis management, there is still a risk of biliary leakage of 5% to 15% following choledochotomy closure. We evaluate the usefulness of fibrin-collagen sealants to reduce the incidence of biliary fistula after laparoscopic choledochorrhaphy. We report a retrospective analysis of 96 patients undergoing LCBDE from March 2009 to March 2017, whose closure of the bile duct was completed by antegrade stenting and choledochorraphy or by performing a primary suture. The study population was divided into two groups according to whether they received a collagen-fibrin sealant covering the choledochorrhaphy or not, analyzing the incidence of postoperative biliary fistula in each group. Thirty-nine patients (41%) received a fibrin-collagen sponge while the bile duct closure was not covered in the remaining 57 patients (59%). The incidence of biliary fistula was 7.7% (3 patients) in the first group and 14% (8 patients) in the second group (P=.338). In patients who underwent primary choledochorraphy, the fibrin-collagen sealant reduced the incidence of biliary leakage significantly (4.5% vs. 33%, P=.020), which was a protective factor with an odds ratio of 10.5. Fibrin-collagen sealants may decrease the incidence of biliary fistula in patients who have undergone primary bile duct closure following LCBDE. Copyright © 2018 AEC. Publicado por Elsevier España, S.L.U. All rights reserved.

  17. Effect of sealant agents on the color stability and surface roughness of nanohybrid composite resins.

    Science.gov (United States)

    Dede, Doğu Ömür; Şahin, Onur; Koroglu, Aysegül; Yilmaz, Burak

    2016-07-01

    The effect of sealant agents on the surface roughness and color stability of nanohybrid composite resins is unknown. The purpose of this in vitro study was to evaluate the effect of sealant agents on the surface roughness and color stability of 4 nanohybrid composite resin materials. Forty disks (10×2 mm) were fabricated for each nanohybrid composite resin material (Z-550, Tetric EvoCeram, Clearfill Majesty, Ice) (N=160) and divided into 4 surface treatment groups: 1 conventional polishing (control) and 3 different sealant agent (Palaseal, Optiglaze, BisCover) coupling groups (n=10). The specimens were thermocycled, and surface roughness (Ra) values were obtained with a profilometer. Scanning electron microscope images were also recorded. CIELab color parameters of each specimen were measured with a spectrophotometer before and after 7 days of storage in a coffee solution. Color differences were calculated by the CIEDE 2000 (ΔE00) formula. The data were statistically analyzed by 2-way ANOVA and by the Tukey HSD test (α=.05). The surface treatment technique significantly affected the Ra values of the composite resins tested (Pcomposite resin material was also significant for ΔE00 values (Pcomposite resin groups, significant decreases in Ra were observed only for the Palaseal agent coupled composite resin groups (except Ice) compared with the control groups (Pcomposite resin group, except for BisCover applied Clearfill Majesty (Pcomposite resin groups, significant differences were observed between the color change seen with BisCover and other sealants for Clearfill Majesty composite resin (Pcomposite resins except for Ice produced smoother surfaces. All surface sealant agents provided less discoloration of nanohybrid composite resins after coffee staining compared with conventional polishing except for BisCover applied Clearfill Majesty composite resin. Copyright © 2016 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All

  18. Clinical Evaluation of an Adhesive Sealant for Controlling Dental Caries in Naval Personnel: One-Year Results

    Science.gov (United States)

    1974-08-20

    safeguards were employed in that a voltage monitoring strip chart recorder was employed during sealant placement to ensure continuous delivery of...adequate voltage to the ultraviolet light source (Nuva- Lite)* used for sealant polymerization. Also, a new air compressor** with suitable...ment effect in young Naval personnel. 2. The very low occlusal attack rate for untreated control teeth 3. Dirks, O. B., Houwink, B. and Kwant , G. W

  19. Frequency of remnants of sealants left behind in pits and fissures of occlusal surfaces after 2 and 3 years.

    NARCIS (Netherlands)

    Hu, X.; Zhang, W.; Fan, M.; Mulder, J.; Frencken, J.E.F.M.

    2017-01-01

    OBJECTIVES: The null-hypothesis tested was that there was no difference in the frequency of remnants of high-viscosity glass-ionomer sealants left behind in pits and fissures of occlusal surfaces of first permanent molars and that of resin composite and glass-carbomer sealants. MATERIALS AND

  20. A clinical trial to evaluate the retention of a silver cermet-ionomer cement used as a fissure sealant.

    Science.gov (United States)

    Mills, R W; Ball, I A

    1993-01-01

    A randomized clinical trial was under-taken to compare the retention of a silver cermet-ionomer cement, Ketac Silver, with a conventional, autopolymerizing BIS-GMA resin sealant, Delton, using matched pairs of fissure sites within each subject's mouth. One hundred twenty matched contralateral pairs of fissure sites in first and second permanent molars of 53 school children were sealed with the two materials. The choice of site and material was selected at random. The ages of the children ranged from five to 16 years; first permanent molars were sealed in the five- to 10-year age group, and second permanent molars in the 11- to 16-year age group. Sealants were assessed as present, partly present, or absent at 6, 12, and 24 months. The number of pairs of sites available for reassessment declined from 102 at six months to 59 at 24 months as patients were lost to the study. Retention rates were higher for the Ketac Silver sealants at all three inspection intervals (P cermet cement was better retained than conventional resin sealants in younger children.

  1. Pit and fissure sealants versus fluoride varnishes for preventing dental decay in children and adolescents

    DEFF Research Database (Denmark)

    Hiiri, Anne; Ahovuo-Saloranta, Anneli; Nordblad, Anne

    2010-01-01

    the effectiveness of pit and fissure sealants to be statistically significantly higher than an application of fluoride varnish every 6 months in preventing occlusal decays of first molars at 23 months (with a RR of 0.74, 95% confidence interval (CI) 0.58 to 0.95); and at 4 years and 9 years (with a RR of 0.42, 95...... caries on the fluoride varnished tooth surfaces, compared to sealed plus fluoride varnished surfaces, with a RR of 0.36 (95% CI 0.21 to 0.61). AUTHORS' CONCLUSIONS: There was some evidence on the superiority of pit and fissure sealants over fluoride varnish application in the prevention of occlusal......BACKGROUND: The majority of the detected increment in dental caries among children and adolescents is confined to pit and fissure surfaces of first molars. OBJECTIVES: The objective of this study was to compare the effectiveness of pit and fissure sealants with fluoride varnishes in the prevention...

  2. Chylothorax after mediastinal ganglioneuroma resection treated with fibrin sealant patch: a case report

    Science.gov (United States)

    Chiarelli, Marco; Achilli, Pietro; Guttadauro, Angelo; Vertemati, Giuseppe; Terragni, Sabina; De Simone, Matilde

    2017-01-01

    Chylothorax is a severe condition resulting from the accumulation of chyle into the pleural space. We report the treatment of postoperative chylothorax after resection of mediastinal ganglioneuroma in a 17-year-old boy. Since conservative measures were not effective, we performed direct ligation of lymphatic vessels and pleurodesis. At subsequent surgical re-exploration for persisting chylothorax, accurate inspection of pleural cavity revealed residual chyle leakage. Fibrin sealant patches (TachoSil®) were placed over the source of leak with complete resolution of chylous effusion. To our knowledge, this is the first report of postoperative chylothorax successfully treated by the use of a fibrin sealant patch. PMID:29221335

  3. The effect of surface sealants with different filler content on microleakage of Class V resin composite restorations.

    Science.gov (United States)

    Hepdeniz, Ozge Kam; Temel, Ugur Burak; Ugurlu, Muhittin; Koskan, Ozgur

    2016-01-01

    Microleakage is still one of the most cited reasons for failure of resin composite restorations. Alternative methods to prevent microleakage have been investigated increasingly. The aim of this study is to evaluate the microleakage in Class V resin composite restorations with or without application of surface sealants with different filler content. Ninety-six cavities were prepared on the buccal and lingual surfaces with the coronal margins located in enamel and the cervical margins located in dentin. The cavities restored with an adhesive system (Clearfil SE Bond, Kuraray, Tokyo, Japan) and resin composite (Clearfil Majesty ES-2, Kuraray, Tokyo, Japan). Teeth were stored in distilled water for 24 h and separated into four groups according to the surface sealants (Control, Fortify, Fortify Plus, and G-Coat Plus). The teeth were thermocycled (500 cycles, 5-55° C), immersed in basic fuchsine, sectioned, and analyzed for dye penetration using stereomicroscope. The data were submitted to statistical analysis by Kruskal-Wallis and Bonferroni-Dunn test. The results of the study indicated that there was minimum leakage at the enamel margins of all groups. Bonferroni-Dunn tests revealed that Fortify and GC-Coat groups showed significantly less leakage than the Control group and the Fortify Plus group at dentin margins in lingual surfaces (P < 0.05). The all surface sealants used in this study eliminated microleakage at enamel margins. Moreover, unfilled or nanofilled surface sealants were the most effective in decreasing the degree of marginal microleakage at dentin margins. However, viscosity and penetrability of the sealants could be considered for sealing ability besides composition.

  4. Prevalence of sealants in relation to dental caries on the permanent molars of 12 and 15-year-old Greek adolescents. A national pathfinder survey

    Directory of Open Access Journals (Sweden)

    Mamai-Homata Eleni

    2011-02-01

    Full Text Available Abstract Background The use of sealants as an effective measure for the prevention of pit and fissure caries in children has been well documented by several studies; either they are used on an individual or on a public health basis. In order to plan and establish a national preventive program with sealants in a community, it is mandatory to know the epidemiological pattern of caries along with other variables influencing their use and effectiveness. Aims: To assess the utilization and distribution pattern of pit and fissure sealants on the first and second permanent molars of Greek adolescents and to evaluate whether the existing usage of sealants and some socio-demographic factors are correlated to caries prevalence on the population examined Methods A stratified cluster sample of 2481 Greek adolescents was selected according to WHO guidelines (1224 twelve and 1,257 fifteen-year-old, living in urban and rural areas in 11 districts within the country. Five calibrated examiners carried out clinical examinations, recording caries experience at the dentine threshold (BASCD criteria and presence or absence of sealants along with Socio-demographic indicators associated with oral health. Mann Whitney and Pearson's chi-square non parametric tests were utilized for assessing the data. The level of significance was p Results Sealants utilization varied considerably within the different districts, with 8,3% of the 12 and 8,0% of the 15-year-old adolescents having at least one sealed molar. Sealants reduced DMFS scores by 11% in the 12-year-olds and by 24% in the 15-year-olds, while 15-year-old adolescents from rural areas had a statistically significant (p = 0.002 less chance of having sealants (71% compared to children from urban areas. Girls had higher chance to receive sealants in both age groups (26% for the 12 and 19% for the 15-year-old as well as patients that visited the dentist for prevention compared to those visiting the dentist because they

  5. The differences of saliva pH before and after application of Bis-GMA resin based-pit and fissure sealant

    Directory of Open Access Journals (Sweden)

    Ayub Irmadani Anwar

    2016-06-01

    Full Text Available Pit and fissure sealant applications is one way to prevent caries. One of the effective ingredient as a pit and fissure sealant is a Bis-GMA resin. One of the active components  of  Bis-GMA  resin  is  sodium  fluoride,  which is capable  of releasing fluoride ions to the tooth surface and able to improve the repair and remineralization process through the replacement  of  calcium and phosphate ions found in saliva to increase the pH of saliva. This study was to determine the effect of pit and fissure sealant applications made from Bis-GMA resin to pH of saliva in children aged 6-12 years. The study design is pre and post test with control group design. Saliva samples were derived from 15 pediatric patients has met the criteria. The pH of saliva were taken before and after the application of pit and fissure sealant made from Bis-GMA and measured with pH meter. This study used a non-parametric test, the Wilcoxon Signed Rank test. The results of this study are also supported by the results of statistical tests showed p-: 0.005 (p<0.05 value, which means that there are significant differences in pH of saliva before and after the application of pit and fissure sealant made from Bis-GMA resin.

  6. Transcutaneous Drainage of Gel-Like Substance after Application of Hydrogel Dural Sealant: Report of Two Cases

    OpenAIRE

    Siman, Homayoun; Techy, Fernando

    2015-01-01

    Study Design?Case report. Objective?Incidental durotomy (IDT) is a common complication of spinal surgery. The use of collagen matrix graft along with hydrogel dural sealant is a common method of IDT repair. With this method, there have been several reported cases of detrimental dural sealant expansion in the literature. One case study reported an expansion rate greater than 300%; many report neurologic damage. This article reports the clinical course of two patients who developed postoperativ...

  7. Use of a sealant to prevent prolonged air leaks after lung resection: a prospective randomized study.

    Science.gov (United States)

    Lequaglie, Cosimo; Giudice, Gabriella; Marasco, Rita; Morte, Aniello Della; Gallo, Massimiliano

    2012-10-08

    Pulmonary air leaks are common complications of lung resection and result in prolonged hospital stays and increased costs. The purpose of this study was to investigate whether, compared with standard care, the use of a synthetic polyethylene glycol matrix (CoSeal®) could reduce air leaks detected by means of a digital chest drain system (DigiVent™), in patients undergoing lung resection (sutures and/or staples alone). Patients who intraoperatively showed moderate or severe air leaks (evaluated by water submersion tests) were intraoperatively randomized to receive just sutures/staples (control group) or sutures/staples plus CoSeal® (sealant group). Differences among the groups in terms of air leaks, prolonged air leaks, time to chest tube removal, length of hospital stay and related costs were assessed. In total, 216 lung resection patients completed the study. Nineteen patients (18.1%) in the control group and 12 (10.8%) patients in the sealant group experienced postoperative air leaks, while a prolonged air leak was recorded in 11.4% (n=12) of patients in the control group and 2.7% (n=3) of patients in the sealant group. The difference in the incidence of air leaks and prolonged air leaks between the two groups was statistically significant (p=0.0002 and p=0.0013). The mean length of hospital stay was significantly shorter in the sealant group (4 days) than the control group (8 days) (p=0.0001). We also observed lower costs in the sealant group than the control group. The use of CoSeal® may decrease the occurrence and severity of postoperative air leaks after lung resection and is associated with shorter hospital stay. Not registered. The trial was approved by the Institutional Review Board of the IRCCS-CROB Basilicata Regional Cancer Institute, Rionero in Vulture, Italy.

  8. Effect of Acidulated Phosphate Fluoride (APF on the Mcroleakage of Composite Flow and Fssure Sealant Restorations

    Directory of Open Access Journals (Sweden)

    Arash Poorsattar Bejeh Mir

    2012-09-01

    Full Text Available Background and Aims: A large number of investigations have revealed that physical and chemical alterations and weight loss could occur in composite materials exposed to acidic phosphate fluoride (APF gel. The purpose of this study was to assess the microleakage of a fissure sealant and a flow composite exposed to acidulated phosphate fluoride (APF gel. Materials and Methods: In this in vitro study, 60 intact human extracted premolar teeth were used. After preparing the occlusal groove, the teeth were divided into two groups (n=30. Teeth were filled with either Helioseal fissure sealant (Vivadent, Germany or Tetric flow composite (Vivadent, Germany. After that, each group was divided into two subgroups (n=15: 1.23% APF gel (Sultan, U.S.A was applied in the case subgroups, while control subgroups were preserved in normal saline solution. All of teeth were covered with 2 layers of nail varnish except for the filling zone and 1mm around the border of filling. After submerging in 0.5% fushin solution, specimens were sectioned bucco-lingually. Then dye penetration through the filling and fissure sealant was assessed by means of a stereo-microscope. The depth of dye penetration was scored. The data were analyzed using One-way ANOVA and Levene test. Results: The mean values of dye penetration were 1.26±1.09, 1.4±1.05, 1.2±1.37, and 1.4±1.35 for fissure sealant+gel, composite+gel, composite+normal saline, and normal saline groups, respectively. No significant difference was found in inter-groups (P=0.96. Conclusion: Considering the result of the present research, APF gel had no significant effect on the microleakage of Tetric flow composite filling and Helioseal fissure sealant and thus, it can be applied for routine usage.

  9. Radon penetration of concrete slab cracks, joints, pipe penetrations, and sealants

    NARCIS (Netherlands)

    Nielson, KK; Rogers, VC; Holt, RB; Pugh, TD; Grondzik, WA; deMeijer, RJ

    1997-01-01

    Radon movement through 12 test slabs with different cracks, pipe penetrations, cold joints, masonry blocks, sealants, and tensile stresses characterized the importance of these anomalous structural domains, Diffusive and advective radon transport were measured with steady-state air pressure

  10. Comparison of Caries Prevention With Glass Ionomer and Composite Resin Fissure Sealants

    Directory of Open Access Journals (Sweden)

    Aylin Akbay Oba

    2009-11-01

    Conclusion: Under field conditions in which moisture control was not effective, a high-viscosity and less technique-sensitive glass ionomer material can be used as an effective sealant material, rather than resin.

  11. Usefulness of hemostatic sealants for minimizing ovarian damage during laparoscopic cystectomy for endometriosis.

    Science.gov (United States)

    Choi, Chahien; Kim, Woo Young; Lee, Dong Hee; Lee, San Hui

    2018-03-01

    We aimed to evaluate the impact of topical hemostatic sealants and bipolar coagulation during laparoscopic ovarian endometriotic cyst resection on ovarian reserve by comparing the rates of decrease in anti-Müllerian hormone (AMH). A randomized prospective data collection was made on women aged 19-45 years who planned to have laparoscopic ovarian cystectomy at one of two institutions (n = 80), Kangbuk Samsung Hospital, Seoul, Korea or National Health Insurance Service Ilsan Hospital, Goyang, Korea, from January 2014 to April 2016. Patients were randomly divided into two groups treated with either a topical hemostatic sealant or bipolar coagulation for hemostasis. The hemostatic group was randomized to the FloSeal or TachoSil subgroups. Preoperative and 3-month postoperative AMH levels were checked and the rates of decrease of AMH were compared. All patients enrolled were treated with dienogest (Visanne) for 6-12 months. None were lost to follow-up at postoperative 3 months, but about one-third of the patients had been lost to follow-up by 6-12 months. AMH was significantly decreased in both groups 3 months postoperatively; however, the rate of decrease in the bipolar coagulation group was greater than that in the hemostatic sealant group, 41.9% (interquartile range [IQR], 22.29-65.24) versus 18.1% (IQR, 10.94-29.90), P = 0.007. Between the two hemostatic subgroups, there was no significant difference in AMH decrease rate, 14.95% (IQR, 11.34-21.21) versus 18.1% (IQR 9.76-40.70), P = 0.204. Hemostatic sealants may be an alternative to bipolar coagulation for preservation of ovarian reserve after laparoscopic ovarian cystectomy for endometriosis. © 2017 Japan Society of Obstetrics and Gynecology.

  12. Prevalence of Dental Caries and Fissure Sealants in a Portuguese Sample of Adolescents

    Science.gov (United States)

    Veiga, Nélio J.; Pereira, Carlos M.; Ferreira, Paula C.; Correia, Ilidio J.

    2015-01-01

    Introduction The aims of this study were to assess the prevalence of dental caries and the DMFT index, as well as the distribution pattern of pit and fissure sealants on permanent teeth in a Portuguese sample of adolescents, and to assess whether the existing usage of sealants and socio-demographic factors are correlated to caries prevalence on the examined sample. Materials and Methods A cross-sectional study was designed with a sample of 447 adolescents aged 12 to 18 years old, attending a public school in Sátão, Portugal. A self-administered questionnaire with questions about oral health behaviours and socio-economic status was answered by adolescents in the classroom. Clinical examination of oral health status and assessment of fissure sealants were accomplished by only one trained member of the research team. Results We obtained a DMFT index of 3.32 (2.92), which indicates a moderate level of prevalence of dental caries. When considering a DMFT = 0, we found significant statistical differences between the parents´ level of education (≤ 4th grade = 26.3 vs 5th–12th grade = 18.8 vs Portuguese adolescents. The establishment of a more targeted preventive program with better and more effective oral health education is essential, having into account socio-demographic aspects. PMID:25803849

  13. Social Marketing Risk-Framing Approaches for Dental Sealants in Rural American Indian Children.

    Science.gov (United States)

    Larsson, Laura S; Champine, Dorothy; Hoyt, Dee; Lin, Lillian; Salois, Emily; Silvas, Sharon; Tail, Terri Weasel; Williams, Matthew

    2015-01-01

    To compare three variants of a culturally relevant and theoretically based message to determine the most influential risk-framing approach for improving intention to place dental sealants for preschool children. A convenience sample of adult, American Indian participants (n = 89) attending a community health fair were assigned to view a gain-framed, loss-framed, or mix-framed dental sealant message. We compared participants' scores on a 46-item survey to determine the relative effect of the frame assignment on seven indices of behavior change. The mean difference in participants' stage-of-change scores (x = 1.17, n = 89, SD = 1.90) demonstrated a significant improvement for all groups after watching the dental sealant message t88  = 5.81, p mix-framed message resulted in the highest scores. The gain-framed message was the least influential on four constructs. This finding is in contrast to findings that gain-framed oral health messages are most influential (Gallagher & Updegraff, 2012; O'Keefe & Jensen, 2007). Community advisory board members determined to use the mix-framed approach in an oral health social marketing campaign with a rural, American Indian audience. © 2015 Wiley Periodicals, Inc.

  14. Effect of artificial aging on the bond durability of fissure sealants.

    Science.gov (United States)

    Yun, Xiaofei; Li, Wei; Ling, Chen; Fok, Alex

    2013-06-01

    To evaluate the effect of artificial aging on the bond durability of fissure sealants in vitro. Twenty bovine incisors received 4 different sealant treatments and were divided into four groups: 1. Ultraseal XT plus (UX); 2. Enamel Loc (EL); 3. 35% phosphoric acid plus Enamel Loc (PEL); 4. Adper Prompt L-Pop plus Clinpro (PPC). Beam-shaped specimens were prepared and randomly divided into three subgroups. One subgroup underwent the microtensile bond strength (µTBS) test after 24-h storage in 37°C water. The other two subgroups were also subjected to the microtensile bond strength test after 5000 and 10,000 thermal cycles, respectively. Another twelve intact human third molars were sealed using 1 of 3 methods and were divided into 3 groups of 4 each: 1. Ultraseal XT plus; 2. Adper Prompt L-Pop plus Clinpro; and 3. Enamel Loc. Two specimens from each group were immersed in a 50% silver nitrate solution for 24 h, followed by exposure to fluorescent light for 8 h, before being scanned in a micro-CT (microcomputer tomography) machine. The other two were handled in the same way after undergoing 10,000 thermal cycles. The CT images obtained were evaluated. All samples from the EL group were broken during preparation, so no µTBS results were available. After 5000 thermal cycles, the bond strengths of the three other groups (UX, PEL, PPC) decreased significantly (p artificial aging. Micro-CT, a nondestructive analytical tool, may be used to evaluate the sealant/enamel interface effectively.

  15. Knowledge, value, opinion and practice about usage of pit and fissure sealant among dental professionals in Chennai, Tamil Nadu, India.

    Science.gov (United States)

    Nagappan, N; Dhamodhar, M Dinesh; Nithin, M G; Kumar, E Senthil

    2015-12-01

    A study was aimed to assess the knowledge, value, opinion, and practice regarding the use of dental sealants among private dental practitioners in Chennai, Tamil Nadu, India. A self-administrated questionnaire were distributed to 192 private dental practitioners in Chennai, Tamil Nadu, India by using simple random sampling. A convenience sampling technique was employed. The questionnaire consisted of 28 items, which included information about knowledge, value, opinion, and practice regarding dental sealants. The questionnaire was obtained from the study by San Martin et al. 2013 and Kailash Asawa et al. 2014. Frequency distribution was tabulated. For frequency distribution strongly, strongly agree, and agree were combined as "agree" and strongly disagree and disagree were combined as "disagree." There were no changes in "neutral." Among the 196 study subjects 56.2% were males and 43.8% were females with their clinical experience of 52.1% for 15 years. The mean scores for knowledge, value, opinion, and practice were 41.8 ± 3.7, 18.7 ± 2.8, 18.1 ± 1.4, and 12.9 ± 2.3, respectively. The results suggest that dental practitioners had satisfactory knowledge about pit and fissure sealant and had neutral attitudes about sealants being effective. Dental practitioners adequately used the pit and fissure sealants but they did not follow the standardized procedures and specific guidelines.

  16. Initial experience with a synthetic sealant PleuraSeal™ after pulmonary resections: a prospective study with retrospective case matched controls

    Directory of Open Access Journals (Sweden)

    Hennings Ellen

    2010-06-01

    Full Text Available Abstract The objective of this study was to evaluate postoperative outcome and efficacy of a hydrogel tissue sealant for prevention of alveolar leakage after open lung resections. 20 consecutive patients were enrolled in the PleuraSeal™ sealant group (PSG and case matched with 20 retrospective controls (CG with standard treatment. Assessment of postoperative air leakage was performed until chest tube removal. Patients were followed until 30 days after discharge. At end of surgery, 100% in the PSG and 0% in the CG were air leak free (p The study demonstrated a superior efficacy of PleuraSeal™ sealant compared with standard surgical treatment for sustained sealing of postoperative air leakage and causes shorter air leak chest tube duration.

  17. Chemically bonded phosphate ceramic sealant formulations for oil field applications

    Science.gov (United States)

    Wagh, Arun S [Naperville, IL; Jeong, Seung-Young [Taejon, KR; McDaniel, Richard [Crest Hill, IL

    2008-10-21

    A sealant for an oil or geothermal well capable of setting within about 3 to about 6 hours at temperatures less than about 250.degree. F. for shallow wells less than about 10,000 feet and deep wells greater than about 10,000 feet having MgO present in the range of from about 9.9 to about 14.5%, KH.sub.2PO.sub.4 present in the range of from about 29.7 to about 27.2%, class C fly ash present in the range of from about 19.8 to about 36.3%, class F fly ash present in the range of from about 19.8 to about 0%, boric acid or borax present in the range of from about 0.39 to about 1.45%, and water present in the range of from about 20.3 to about 21.86% by weight of the sealant.A method of sealing wells is disclosed as are compositions for very high temperature wells is disclosed as is a composition for treating oil field wastes.

  18. Use of a sealant to prevent prolonged air leaks after lung resection: a prospective randomized study

    Directory of Open Access Journals (Sweden)

    Lequaglie Cosimo

    2012-10-01

    Full Text Available Abstract Background Pulmonary air leaks are common complications of lung resection and result in prolonged hospital stays and increased costs. The purpose of this study was to investigate whether, compared with standard care, the use of a synthetic polyethylene glycol matrix (CoSeal® could reduce air leaks detected by means of a digital chest drain system (DigiVent™, in patients undergoing lung resection (sutures and/or staples alone. Methods Patients who intraoperatively showed moderate or severe air leaks (evaluated by water submersion tests were intraoperatively randomized to receive just sutures/staples (control group or sutures/staples plus CoSeal® (sealant group. Differences among the groups in terms of air leaks, prolonged air leaks, time to chest tube removal, length of hospital stay and related costs were assessed. Results In total, 216 lung resection patients completed the study. Nineteen patients (18.1% in the control group and 12 (10.8% patients in the sealant group experienced postoperative air leaks, while a prolonged air leak was recorded in 11.4% (n = 12 of patients in the control group and 2.7% (n = 3 of patients in the sealant group. The difference in the incidence of air leaks and prolonged air leaks between the two groups was statistically significant (p = 0.0002 and p = 0.0013. The mean length of hospital stay was significantly shorter in the sealant group (4 days than the control group (8 days (p = 0.0001. We also observed lower costs in the sealant group than the control group. Conclusion The use of CoSeal® may decrease the occurrence and severity of postoperative air leaks after lung resection and is associated with shorter hospital stay. Trial registration Not registered. The trial was approved by the Institutional Review Board of the IRCCS-CROB Basilicata Regional Cancer Institute, Rionero in Vulture, Italy.

  19. Fibrin sealants or cell saver eliminate the need for autologous blood donation in anemic patients undergoing primary total knee arthroplasty.

    Science.gov (United States)

    Bou Monsef, Jad; Buckup, Johannes; Waldstein, Wenzel; Cornell, Charles; Boettner, Friedrich

    2014-01-01

    Reducing allogeneic blood transfusions remains a challenge in total knee arthroplasty. Patients with preoperative anemia have a particularly high risk for perioperative blood transfusions. 176 anemic patients (Hb < 13.5 g/dl) undergoing total knee replacement were prospectively evaluated to compare the effect of a perioperative cell saver (26 patients), intraoperative fibrin sealants (5 ml Evicel, Johnson & Johnson Wound Management, Ethicon, Somerville, NJ) (45 patients), preoperative autologous blood donation (PABD) (21 patients), the combination of fibrin sealants and preoperative autologous blood donation (44) and no intervention (40 patients) on perioperative blood loss and transfusion requirements. All protocols resulted in significant reduction of allogeneic blood transfusions. Transfusion rates were similar with the use of PABD (19%), Evicel (18%), and cell saver (19%), all significantly lower than the control group (38 %, p < 0.05). Combining Evicel with PABD resulted in significantly higher wastage of autologous units (p < 0.05) with no significant reduction in allogeneic transfusion rate (14%). The use of fibrin sealant resulted in a significant reduction of blood loss compared to the PABD group (603 vs. 810 ml, p < 0.005) as well as the control group (603 vs. 822 ml, p < 0.005). While PABD proved to be the most cost-effective treatment option in anemic patients, fibrin sealants and cell saver show similar reduction in allogeneic transfusion rates compared to controls. The combination of fibrin sealants and PABD is not cost-effective and increases the number of wasted units.

  20. A randomised trial of lung sealant versus medical therapy for advanced emphysema

    NARCIS (Netherlands)

    Come, Carolyn E.; Kramer, Mordechai R.; Dransfield, Mark T.; Abu-Hijleh, Muhanned; Berkowitz, David; Bezzi, Michela; Bhatt, Surya P.; Boyd, Michael B.; Cases, Enrique; Chen, Alexander C.; Cooper, Christopher B.; Flandes, Javier; Gildea, Thomas; Gotfried, Mark; Hogarth, D. Kyle; Kolandaivelu, Kumaran; Leeds, William; Liesching, Timothy; Marchetti, Nathaniel; Marquette, Charles; Mularski, Richard A.; Pinto-Plata, Victor M.; Pritchett, Michael A.; Rafeq, Samaan; Rubio, Edmundo R.; Slebos, Dirk-Jan; Stratakos, Grigoris; Sy, Alexander; Tsai, Larry W.; Wahidi, Momen; Walsh, John; Wells, J. Michael; Whitten, Patrick E.; Yusen, Roger; Zulueta, Javier J.; Criner, Gerard J.; Washko, George R.

    Uncontrolled pilot studies demonstrated promising results of endoscopic lung volume reduction using emphysematous lung sealant (ELS) in patients with advanced, upper lobe predominant emphysema. We aimed to evaluate the safety and efficacy of ELS in a randomised controlled setting. Patients were

  1. INVESTIGATION OF THE POTENTIAL ANTIMICROBIAL EFFICACY OF SEALANTS USED IN HVAC SYSTEMS

    Science.gov (United States)

    The paper gives results of an investigation of the potential antimicrobial efficacy of sealants used in heating, ventilation and air-conditioning systems. Recent experiments confirm field experience that duct cleaning alone may not provide adequate protection from regrowth of fu...

  2. Fixation of osteochondral fractures in rabbit knees. A comparison of Kirschner wires, fibrin sealant, and polydioxanone pins.

    Science.gov (United States)

    Plaga, B R; Royster, R M; Donigian, A M; Wright, G B; Caskey, P M

    1992-03-01

    We compared fibrin sealant, polydioxanone (PDS) pins and Kirschner wires in the fixation of osteochondral fractures in rabbit knees. Standardised osteochondral fractures of the right medial femoral condyle were made in 56 adult New Zealand white rabbits. There were equal groups of control knees, and those which had Kirschner-wire, fibrin-sealant or PDS-pin fixation. No external immobilisation was used. One animal from each group was killed at two, three and four weeks. The remaining rabbits were killed at six weeks. A fracture which healed with less than 1 mm of displacement was considered a success. There was successful healing in 29% of the control group, in all of the Kirschner-wire group, in 50% of the fibrin-sealant group, and in 86% of the PDS-pin group. The use of PDS pins appears to be a reliable alternative to the use of metal in the fixation of osteochondral fractures in rabbits.

  3. Design approach to sealant selection for the life of the well

    NARCIS (Netherlands)

    Bosma, M.; Ravi, K.; Driel, W.D. van; Schreppers, G.M.A.

    1999-01-01

    Recent experience in the field has demonstrated that the mechanical properties of the annular sealant are a critical factor in the success of a well. A demanding operational regime of the well such as High Pressure/High Temperature (HP/HT) and well interventions, e.g. pressure testing stimulation,

  4. Evaluation of asbestos exposure within the automotive repair industry: a study involving removal of asbestos-containing body sealants and drive clutch replacement.

    Science.gov (United States)

    Blake, Charles L; Dotson, G Scott; Harbison, Raymond D

    2008-12-01

    Two independent assessments were performed of airborne asbestos concentrations generated during automotive repair work on vintage vehicles . The first involved removal of asbestos-containing seam sealant, and the second involved servicing of a drive clutch. Despite the relatively high concentrations (5.6-28%) of chrysotile fibers detected within bulk samples of seam sealant, the average asbestos concentration for personal breathing zone (PBZ) samples during seam sealant removal was 0.006 f/cc (fibers/cubic centimeter of air). Many other air samples contained asbestos at or below the analytical limit of detection (LOD). Pneumatic chiseling of the sealant material during removal resulted in 69% of area air samples containing asbestos. Use of this impact tool liberated more asbestos than hand scraping. Asbestos fibers were only detected in air samples collected during the installation of a replacement clutch. The highest asbestos corrected airborne fiber concentration observed during clutch installation was 0.0028 f/cc. This value is approximately 100 times lower than Occupational Safety and Health Administration's (OSHA) permissible exposure limit (PEL) of 0.1f/cc. The airborne asbestos concentrations observed during the servicing of vintage vehicles with asbestos-containing seam sealant and clutches are comparable to levels reported for repair work involving brake components and gaskets.

  5. Clinical performance of a glass ionomer sealant protected with two different resin-based agents over a 2-year follow-up period.

    Science.gov (United States)

    Ulusoy, A T; Tunc, E S; Bayrak, Ş

    2017-03-01

    To evaluate the effects of two different resin coating materials on the clinical performance of a conventional glass ionomer sealant. Permanent first mandibular molars of 60 children aged 6-9 years were sealed with Fuji VII. In each child, G-Coat Plus coating agent was applied to molars on one side and Heliobond coating agent to molars on the opposite side of the mouth. Clinical evaluations were carried out at 1, 6, 12, 18 and 24 months after sealant and coating application. At 1, 6, 12, 18 and 24 months after sealant and coating application, total sealant retention rates were 88%, 40%, 19%, 15% and 9% for molars coated with G-Coat Plus, and 93%, 47%, 17%, 15% and 7% for those coated with Heliobond. The differences between the two coating agents were not statistically significant (p>0.05). No incidence of caries was observed in either group during the two-year evaluation period. Wilcoxon signed rank test was used to compare differences in retention rates and caries incidence by coating agent. Although retention rates of Fuji VII were relatively low and similar for both resin coating agents tested, dental caries were not observed in either group during the 24-month study period. In children with a high risk of caries and partially erupted molars, the use of a glass ionomer sealant with a resin-based coating agent should be encouraged.

  6. Randomized clinical trial of fibrin sealant versus titanium tacks for mesh fixation in laparoscopic umbilical hernia repair

    DEFF Research Database (Denmark)

    Eriksen, J R; Bisgaard, T; Assaadzadeh, S

    2011-01-01

    The use of tacks for mesh fixation may induce pain after surgery for ventral hernia. The aim of this study was to compare postoperative pain after laparoscopic ventral hernia repair (LVHR) with conventional mesh fixation using titanium tacks versus fibrin sealant (FS).......The use of tacks for mesh fixation may induce pain after surgery for ventral hernia. The aim of this study was to compare postoperative pain after laparoscopic ventral hernia repair (LVHR) with conventional mesh fixation using titanium tacks versus fibrin sealant (FS)....

  7. Dental sealants and restorations and urinary bisphenol A concentrations in children in the 2003-2004 National Health and Nutrition Examination Survey.

    Science.gov (United States)

    McKinney, Christy; Rue, Tessa; Sathyanarayana, Sheela; Martin, Michael; Seminario, Ana Lucia; DeRouen, Timothy

    2014-07-01

    Resin-based dental sealants and composites contain bisphenol A-glycidyl methacrylate, a bisphenol A (BPA) derivative. The authors hypothesized that a greater number of sealants or restorations would be associated with higher urinary BPA concentrations. The authors examined urinary BPA measurements (in nanograms per milliliter) and oral examination data for 1,001 children aged 6 to 19 years from data sets of the 2003-2004 National Health and Nutrition Examination Survey (NHANES). They categorized children according to number of occlusal sealants and number of restorations, with four categories in each of the two groups. They estimated associations by using unadjusted and adjusted tobit regression models. The lowest quartile of BPA concentrations ranged from 0.3 ng/mL to 1.9 ng/mL, whereas the highest quartile ranged from 7.3 ng/mL to 149 ng/mL. In adjusted analysis, children with seven to 16 sealants had geometric mean BPA concentrations 25 percent higher than those of children with no sealants (95 percent confidence interval [CI], -14 percent to 82 percent; P = .23). In adjusted analysis, children with seven to 42 restorations had geometric mean BPA concentrations 20 percent higher than those of children with no restorations (95 percent CI, -6 percent to 53 percent; P = .13). Neither of these adjusted estimates was statistically significant. Though the findings were in the direction hypothesized, the authors did not observe a statistically significant association between a greater number of sealants or restorations and higher urinary BPA concentrations. Additional studies are needed to determine the extent of oral and systemic exposure to BPA from resin-based dental restorative materials over time. Dentists should follow this issue carefully as it develops and as the body of evidence grows. There is insufficient evidence to change practice at this time.

  8. Behavior of adhesion forces of silicone adhesive sealants and mastic butyl under the influence of ionizing radiation

    International Nuclear Information System (INIS)

    Costa, Wanderley da

    2012-01-01

    Adhesives are products that can keep materials together by bonds between the surfaces. Sealants are products that can keep filled a space between two surfaces, through a barrier that is configured as a 'bridge' between the two surfaces. The mastic is a product made of a mixture of substances with the primary butyl polymer, with the consistency of a mass not dried that can be used as a sealant. The polysiloxane, also known as silicone are the most important synthetic polymers with inorganic structure, and are matrices of silicone adhesive sealants. To demonstrate the behavior of the adhesive forces of these products under different conditions, we used five different techniques. These products were subjected to two different conditions to verify the behavior of adhesion, one at the environmental condition and another under the ionizing radiation. The results showed not only differences between products (silicone and mastic), but also that the adhesive forces have different behaviors under the conditions which the samples were subjected. With this was reached the goal of this study that aspired show the differences between the mastic and silicone, this last one is often considered - erroneously - the same as mastic. Thus it was proven that: 1. silicone can be regarded as an adhesive and a sealant at ambient conditions, 2. mastic improves substantially adhesion in an environment of ionizing radiation and this property can be an excellent alternative to the adhesive market. (author)

  9. A 12-month clinical evaluation of pit-and-fissure sealants placed with and without etch-and-rinse and self-etch adhesive systems in newly-erupted teeth

    Directory of Open Access Journals (Sweden)

    Maryam Karami Nogourani

    2012-06-01

    Full Text Available OBJECTIVES: The objective of this one-year clinical study was to investigate the effect of two adhesive systems (Adper Single Bond, a two-step etch-and-rinse and Clearfil SE Bond, a two-step self-etch system on pit-and-fissure sealant retention in newly-erupted teeth. This study compared the success of the sealants in mesial and distopalatal grooves with and without these two adhesive systems. MATERIAL AND METHODS: In a clinical trial, 35 children aged 6-8 years undergoing sealant placement were recruited. This one-year clinical study scored 70 mesial and 70 distopalatal sealants of newly-erupted permanent maxillary first molar, with a split-mouth design. All children received sealant alone in one permanent maxillary molar tooth. Children were randomized into two groups. One group received Self-etch (Se bond plus sealant and the other group received Single Bond plus sealant in another permanent maxillary molar tooth. Clinical evaluation at 3, 6 and 12 months was performed and the retention was studied in terms of the success and failure. RESULTS: The success rate of sealant in the distopalatal groove, using SeB at 3, 6 and 12 months was 93.3% (95% CI: 68.0, 99.8, 73.3% (95% CI: 44.9, 92.2 and 66.7% (95% CI: 38.4, 88.2, respectively. It was greater than that of the distopalatal groove in SB group with a success rate of 62.5% (95% CI: 35.4, 84.8, 31.3% (95% CI: 11.8, 58.7 and 31.3% (95% CI: 11.8, 58.7, at the three evaluation periods. The success rate of sealant in the mesial groove using SeB was 86.6% (95% CI: 59.5, 98.3, 53.3% (95% CI: 26.6, 78.7 and 53.3% (95% CI: 26.6, 78.7, while this was 100% (95% CI: 79.4, 100.0, 81.3% (95% CI: 54.4, 96.0 and 81.3% (95% CI: 54.4, 96.0 using SB, at 3, 6 and 12-month evaluation periods. CONCLUSIONS: These results support the use of these two bonding agents in pit-and-fissure sealants under both isolated and contaminated conditions. Further, Se bond seemed to be less sensitive to moisture contamination.

  10. Durability of sealants exposed to outdoor weathering and hot compression cycles

    Science.gov (United States)

    Gregory T. Schueneman; Steven Lacher; Christopher G. Hunt; Christopher C. White; Donald L. Hunston

    2011-01-01

    Sealants play an important role in weatherproofing structures by filling gaps and preventing air and water intrusion. When incorrectly selected or improperly applied, they may fail quickly, compromising durability of the structure. To ensure reliability and prevent the need for costly repairs to structures, it is necessary to measure durability and predict life...

  11. Characterization of low temperature creep properties of crack sealants using bending beam rehometry.

    Science.gov (United States)

    2009-11-01

    Crack sealing has been widely used as a routine preventative maintenance practice. Given its proper installation, crack sealants can extend : pavement service life by three to five years. However, current specifications for the selection of crack sea...

  12. Combination of heterologous fibrin sealant and bioengineered human embryonic stem cells to improve regeneration following autogenous sciatic nerve grafting repair.

    Science.gov (United States)

    Mozafari, Roghayeh; Kyrylenko, Sergiy; Castro, Mateus Vidigal; Ferreira, Rui Seabra; Barraviera, Benedito; Oliveira, Alexandre Leite Rodrigues

    2018-01-01

    Peripheral nerve injury is a worldwide clinical problem, and the preferred surgical method for treating it is the end-to-end neurorrhaphy. When it is not possible due to a large nerve gap, autologous nerve grafting is used. However, these surgical techniques result in nerve regeneration at highly variable degrees. It is thus very important to seek complementary techniques to improve motor and sensory recovery. One promising approach could be cell therapy. Transplantation therapy with human embryonic stem cells (hESCs) is appealing because these cells are pluripotent and can differentiate into specialized cell types and have self-renewal ability. Therefore, the main objective of this study was to find conditions under which functional recovery is improved after sciatic nerve neurorrhaphy. We assumed that hESC, either alone or in combination with heterologous fibrin sealant scaffold, could be used to support regeneration in a mouse model of sciatic nerve injury and repair via autografting with end-to-end neurorrhaphy. Five millimeters of the sciatic nerve of C57BL/6 J mice were transected off and rotated 180 degrees to simulate an injury, and then stumps were sutured. Next, we applied heterologous fibrin sealant and/or human embryonic stem cells genetically altered to overexpress fibroblast growth factor 2 (FGF2) at the site of the injury. The study was designed to include six experimental groups comprising neurorrhaphy (N), neurorrhaphy + heterologous fibrin sealant (N + F), neurorrhaphy + heterologous fibrin sealant + doxycycline (N + F + D), neurorrhaphy + heterologous fibrin sealant + wild-type hESC (N + F + W), neurorrhaphy + heterologous fibrin sealant + hESC off (N + F + T), and neurorrhaphy + heterologous fibrin sealant + hESC on via doxycycline (N + F + D + T). We evaluated the recovery rate using Catwalk and von Frey functional recovery tests, as well as immunohistochemistry analysis. The experiments indicated that

  13. THE EFFECT OF BONDING AND SURFACE SEALANT APPLICATION ON POSTOPERATIVE SENSITIVITY FROM POSTERIOR COMPOSITES

    Directory of Open Access Journals (Sweden)

    Neslihan TEKÇE

    2015-10-01

    Full Text Available Purpose: The purpose of the study was to evaluate the postoperative sensitivity of posterior Class I composite restoration at short-term, restorated with two different all-in-one self-etch adhesives with or without surface sealant application. Materials and Methods: 44 restorations were inserted in 11 patients who required Class I restorations in their molars. Each patient received 4 restorations, thus four groups were formed; (1 G-Aenial Bond (GC, Japan; (2 Clearfil S3 Bond (Kuraray, Japan; (3 G-Aenial Bond+Fortify Plus (Bisco, USA, (4 Clearfil S3 Bond+Fortify Plus. Sensitivity was evaluated at 24h, 7, 15, and 30 days using cold air, ice, and pressure stimuli using a visual analog scale. Comparisons of continuous variables between the sensitivity evaluations were performed using the Friedman’s One-Way Analysis of Variance with repeated measures test (p0.05. The use of Clearfil S3 Bond resulted in almost the same level of postoperative sensitivity as did the use of G-Aenial Bond. The highest sensitivity scores were observed for the surface sealant applied teeth without any statistical significance (p>0.05. Conclusions: Self etch adhesives displayed postoperative sensitivity. The sensitivity scores slightly decreased at the end of 30 days (p>0.05. Surface sealant application did not result in a decrease in sensitivity scores for either dentin adhesives.

  14. Clinical effectiveness and cost-effectiveness of fissure sealants in children and adolescents with a high caries risk

    Directory of Open Access Journals (Sweden)

    Neusser, Silke

    2014-10-01

    Full Text Available [english] In Germany, the application of resin-based pits and fissures sealants on the occlusal surfaces of permanent molars is part of individual prophylaxis for children and adolescents between six and 18 years. The individual prophylaxis is covered by the Statutory Health Insurance since 1993.The report addresses questions on medical effectiveness, cost-effectiveness, as well as ethical, social, and legal implications of pit and fissure sealants in preventing dental caries for children and adolescents at high caries risk. The results of the studies indicate a protective effect of pit and fissure sealants, particularly for children and adolescents at high caries risk. Additionally, the economic evaluation suggests a tendency for cost savings in this group. Nevertheless, a general expansion of the intervention cannot be recommended. All studies show a risk of bias in favour of pit and fissure sealing and a limited transferability to the German health care system. Studies included in the economic evaluation revealed methodological flaws. Both the economic models and primary studies do not provide reliable results.

  15. Color and opacity of composites protected with surface sealants and submitted to artificial accelerated aging.

    Science.gov (United States)

    Aguilar, Fabiano Gamero; Roberti Garcia, Lucas da Fonseca; Cruvinel, Diogo Rodrigues; Sousa, Ana Beatriz Silva; de Carvalho Panzeri Pires-de-Souza, Fernanda

    2012-01-01

    To evaluate the color similarity, stability and opacity of composites (TPH, Charisma, and Concept, shade A2) protected with surface sealants (Fortify Plus and Biscover) and cyanoacrylate (Super Bonder). Forty specimens of each composite were made and separated into 4 groups (n=10) according to the surface protection: GI - without sealant; GII - cyanoacrylate; GIII - Fortify Plus; GIV - Biscover. Color and opacity readings were taken before and after Artificial Acelerated Aging (AAA) and the values obtained for color stability were submitted to statistical analysis by 2-way ANOVA and Bonferroni's test (P<.05). The values acquired for color similarity were submitted to 1-way ANOVA and Tukey's test (P<.05). The specimen sufaces were compared before and after AAA using Scanning Electronic Microscopy (SEM). Studied composites did not present the same values for the coordinates L*, a* and b * before AAA, indicating that there was no color similarity among them. All composites presented color alteration after AAA with clinically unacceptable values. Protected groups presented lower opacity variation after AAA, in comparison with the control goup. SEM evaluation demonstrated that AAA increased the surface irregularities in all of the studied groups. Surface sealants were not effective in maintaining composite color, but were able to maintain opacity.

  16. Percutaneous BioOrganic Sealing of Duodenal Fistulas: Case Report and Review of Biological Sealants with Potential Use in Interventional Radiology

    Energy Technology Data Exchange (ETDEWEB)

    Wadhwa, Vibhor, E-mail: vwadhwa1@jhmi.edu [Johns Hopkins University School of Medicine, Division of Vascular & Interventional Radiology (United States); Leeper, William R., E-mail: rob.leeper@jhmi.edu [Johns Hopkins University School of Medicine, Department of Surgery (United States); Tamrazi, Anobel, E-mail: atamraz1@jhmi.edu [Johns Hopkins University School of Medicine, Division of Vascular & Interventional Radiology (United States)

    2015-08-15

    Biological sealants are being increasingly used in a variety of surgical specialties for their hemostatic and sealing capabilities. However, their use in interventional radiology has not been widely reported. The authors describe a case of duodenal perforation occurring after 15 years of gastric bypass surgery, in whom surgical diversion was unsuccessfully attempted and the leakage was successfully controlled using percutaneous administration of a combination of biological and organic sealants.

  17. THE STATE AND PERSPECTIVE OF HERMETIZATION OF UNDERGROUND STRUCTURES WITH USE OF RUBBER SEALANTS

    Directory of Open Access Journals (Sweden)

    V. I. Leshchenko

    2010-03-01

    Full Text Available The works on creation of effective rubber sealants for hermetic sealing of joints of underground structures from modular ferroconcrete and pig-iron, including tunnel elements for the underground, are carried out.

  18. PAH concentrations in lake sediment decline following ban on coal-tar-based pavement sealants in Austin, Texas

    Science.gov (United States)

    Van Metre, Peter C.; Mahler, Barbara J.

    2013-01-01

    Recent studies have concluded that coal-tar-based pavement sealants are a major source of polycyclic aromatic hydrocarbons (PAHs) in urban settings in large parts of the United States. In 2006, Austin, TX, became the first jurisdiction in the U.S. to ban the use of coal-tar sealants. We evaluated the effect of Austin’s ban by analyzing PAHs in sediment cores and bottom-sediment samples collected in 1998, 2000, 2001, 2012, and 2014 from Lady Bird Lake, the principal receiving water body for Austin urban runoff. The sum concentration of the 16 EPA Priority Pollutant PAHs (∑PAH16) in dated core intervals and surficial bottom-sediment samples collected from sites in the lower lake declined about 44% from 1998–2005 to 2006–2014 (means of 7980 and 4500 μg kg–1, respectively), and by 2012–2014, the decline was about 58% (mean of 3320 μg kg–1). Concentrations of ∑PAH16 in bottom sediment from two of three mid-lake sites decreased by about 71 and 35% from 2001 to 2014. Concentrations at a third site increased by about 14% from 2001 to 2014. The decreases since 2006 reverse a 40-year (1959–1998) upward trend. Despite declines in PAH concentrations, PAH profiles and source-receptor modeling results indicate that coal-tar sealants remain the largest PAH source to the lake, implying that PAH concentrations likely will continue to decline as stocks of previously applied sealant gradually become depleted.

  19. The effect of different enamel surface treatments on microleakage of fissure sealants

    Directory of Open Access Journals (Sweden)

    Asli Topaloglu-Ak

    2013-11-01

    Full Text Available Objective. The aim of this study was to evaluate the effects of different techniques of surface treatment on the microleakage of fissure sealants in permanent molar teeth in vitro. Materials and methods. 96 extracted impacted human third molars were randomly divided into 8 surface treatment groups (n=12/group as 1. Er: YAG laser; (Fidelis II, Fotona, Ljubljana, Slovenia (125 mj, 20Hz. 2. Er: YAG laser + 37% H3PO4 (15s; 3. ER: AG laser + 37% H3PO4+Prime&Bond NT; 4. Er: YAG laser + G Bond; 5. Er: YAG laser + Prime&Bond NT; 6. 37% H3PO4; 7. 37% H3PO4 + Prime &Bond NT; 8. G Bond. Sealant material (Clinpro, 3M ESPE, Seefeld, Germany, was applied into the fissures and light-cured for 20s with LED (Bluephase C5, Ivoclar-Vivadent, Schaan, Liechtenstein. Specimens were subjected to thermocycling (1000×, 5-55°C, dwell time: 15s and immersed in 0.5% basic fuchsin solution for 24h at 37°C. The samples were sectioned and scored on a 3 point rating scale using a light microscope with a magnification of ×20. One-way analysis of variance was used to analyze data. Multiple comparisons were analyzed using Bonferroni test (p=0.05. Results. Er:YAG laser showed the highest microleakage scores whereas Er YAG laser + 37% H3PO4 showed the lowest. Although 37% H3PO4 group showed higher scores than Er:YAG laser + 37% H3PO4, the difference was not statistically significant. Conclusion. Etching fissures with phosphoric acid is sufficient prior to fissure sealant application.

  20. Aluminosilicate-based sealants for SOFCs and other electrochemical applications - A brief review

    Science.gov (United States)

    Tulyaganov, Dilshat U.; Reddy, Allu Amarnath; Kharton, Vladislav V.; Ferreira, José M. F.

    2013-11-01

    Among different designs of solid oxide fuel cells (SOFCs), planar design is the most promising due to easier fabrication, improved performance and relatively high power density. In planar SOFCs and other solid-electrolyte devices, gas-tight seals must be formed along the edges of each cell and between the stack and gas manifolds. For a sealant to work effectively in high-temperature SOFC environment, equilibrium needs to be achieved amid its mechanical properties and flow behavior so that it does not only maintain its hermeticity at high temperature but is also able to reduce mechanical stresses generated in the seal during thermal cycling. The most common sealants based on glass or glass-ceramic materials have been shown to operate in fuel cells for more than 1000 h with no significant degradation. Analysis of the current literature sources demonstrated that from thermal and chemical stability points of view, silicate based glass systems are more suitable than borate and borosilicate glass systems. In this work, different glass-ceramic (GC) compositions based on alkaline- and alkaline-earth aluminosilicate-based glass systems are reviewed with a special emphasis on their thermal, chemical, mechanical, and electrical properties. Based on these considerations, glass composition design approaches are provided that aid in search of the best seal glasses satisfying the rigid functional requirements. Among all the glass systems studied, a pyroxene based CaO-MgO-SrO-BaO-La2O3-Al2O3-SiO2 seal GC compositions have been specifically discussed because those have achieved appropriate thermal and chemical properties along with high stability. Approaches for further developments and optimization of GC sealants are briefly discussed.

  1. Effectiveness of Fibrin Sealant Patch in Reducing Drain Volume after Pelvic Lymph Node Dissection in Women with Gynecologic Malignancy

    Directory of Open Access Journals (Sweden)

    Hwa Cheong Kim

    2017-01-01

    Full Text Available Background. The goal of this study was to evaluate the effectiveness of fibrin sealant in decreasing postoperative lymphatic drainage in women after pelvic lymphadenectomy and/or para-aortic lymphadenectomy during gynecologic cancer surgery. Methods. This study is a retrospective case-control study. Forty-five patients who underwent staging surgery were enrolled. Twenty-seven patients were in the fibrin sealant group (group A and 18 in the control group (group B. The two groups were compared for the total volume of drain, hospital stay, harvested lymph node, and incidence of asymptomatic lymphocele. Lymphocele formation was evaluated by computed tomography (CT on 3 months after surgery. Results. There were no significant differences in patient demographics between group A and B with respect to age, BMI, and harvested lymph nodes. Patients who received fibrin sealants had reduced total volume of drainage from postoperative days 2 to 5 compared to the control group (group A versus group B: 994.819±745.85 ml versus 1847.89±1241.41 ml; P=0.015. However no differences were observed in hospital stay (P=0.282, duration of drain (P=0.207, and incidence of asymptomatic lymphocele at 3 months (P=0.126. Conclusion. The results of this study indicate that the application of fibrin sealants after pelvic and/or para-aortic lymphadenectomy may reduce lymphatic drainage in gynecologic malignancy.

  2. No difference in sexual dysfunction after transabdominal preperitoneal (TAPP) approach for inguinal hernia with fibrin sealant or tacks for mesh fixation

    DEFF Research Database (Denmark)

    Pommergaard, H C; Burcharth, J; Andresen, K

    2017-01-01

    BACKGROUND: Postoperative sexual dysfunction in relation to laparoscopic groin hernia surgery may be related to methods of mesh fixation. However, this has not been investigated earlier. Moreover, results regarding sexual dysfunction in females have not been reported systematically. The aim...... of this study was to compare fibrin sealant versus tacks for fixation of mesh regarding sexual dysfunction in males and females. METHODS: Using the Danish Hernia Database, patients operated laparoscopically for groin hernia with a transabdominal preperitoneal (TAPP) procedure with fibrin sealant or tacks...... for mesh fixation were sent a questionnaire regarding sexual dysfunction. Sexually active patients without recurrence were evaluated in this study. RESULTS: Pain during sexual activity was present in 115 of 1019 (11.3 %) males and 17 of 147 (11.6 %) females. There was no difference between fibrin sealant...

  3. Effect of dry period length on the effect of an intramammary teat sealant on the risk of mastitis in cattle treated with antibiotics at drying off.

    Science.gov (United States)

    Laven, R A; Balcomb, C C; Tulley, W T; Lawrence, K E

    2014-07-01

    The aim of this study was to evaluate, under farm conditions, the use of a teat sealant in addition to whole herd dry cow antibiotic therapy on the risk of clinical mastitis in dairy cattle at pasture, and to evaluate the impact of dry period length on that risk and the impact of the teat sealant on that risk. Dairy cows in three herds which used routine whole herd antibiotic therapy were randomly assigned to receive either treatment with an internal teat sealant (n=322) or no additional treatment (n=313) at drying-off between March and May 2010. All clinical mastitis cases during the dry period and to the end of the subsequent lactation were recorded by farm staff; factors affecting risk of clinical mastitis were then analysed using a Cox proportional hazards model. Median duration of the dry period was 112 days with >25% of cows having a dry period >130 days. The incidence risk of mastitis during lactation for cows treated with teat sealant was 9.9 (95% CI=6.9-13.7) cases per 100 cows compared with 17.9 (95% CI=13.8-22.6) cases per 100 cows for cows treated with antibiotic alone. The addition of a teat sealant to dry cow antibiotic therapy decreased the risk of clinical mastitis only in the first 33 days after calving (Hazard risk 0.24 (95% CI=0.12-0.48)). Length of dry period did not significantly affect the risk of clinical mastitis, or the effect of adding teat sealant to dry cow antibiotic therapy on the risk of clinical mastitis. In these herds where, based on the mastitis history, whole herd antibiotic therapy had been recommended, the use of a teat sealant significantly reduced the risk of clinical mastitis. This effect was limited to the first 33 days after calving; subsequently there was no significant effect of treatment. There was no effect of dry period length on risk of clinical mastitis, nor any significant interaction with treatment. Combination therapy with teat sealant and antibiotic was effective under New Zealand conditions in herds using whole

  4. Autologous fibrin sealant (Vivostat®) in the neurosurgical practice: Part I: Intracranial surgical procedure

    Science.gov (United States)

    Graziano, Francesca; Certo, Francesco; Basile, Luigi; Maugeri, Rosario; Grasso, Giovanni; Meccio, Flavia; Ganau, Mario; Iacopino, Domenico G.

    2015-01-01

    Background: Hemorrhages, cerebrospinal fluid (CSF) fistula and infections are the most challenging postoperative complications in Neurosurgery. In this study, we report our preliminary results using a fully autologous fibrin sealant agent, the Vivostat® system, in achieving hemostasis and CSF leakage repair during cranio-cerebral procedures. Methods: From January 2012 to March 2014, 77 patients were studied prospectively and data were collected and analyzed. Autologous fibrin sealant, taken from patient's blood, was prepared with the Vivostat® system and applied on the resection bed or above the dura mater to achieve hemostasis and dural sealing. The surgical technique, time to bleeding control and associated complications were recorded. Results: A total of 79 neurosurgical procedures have been performed on 77 patients. In the majority of cases (98%) the same autologous fibrin glue provided rapid hemostasis and dural sealing. No patient developed allergic reactions or systemic complications in association with its application. There were no cases of cerebral hematoma, swelling, infection, or epileptic seizures after surgery whether in the immediate or in late period follow-up. Conclusions: In this preliminary study, the easy and direct application of autologous fibrin sealant agent helped in controlling cerebral bleeding and in providing prompt and efficient dural sealing with resolution of CSF leaks. Although the use of autologous fibrin glue seems to be safe, easy, and effective, further investigations are strongly recommended to quantify real advantages and potential limitations. PMID:25984391

  5. Application of rape pod sealants to reduce adverse environmental impacts.

    Science.gov (United States)

    Bauša, Laimis; Steponavičius, Dainius; Jotautienė, Eglė; Kemzūraitė, Aurelija; Zaleckas, Ernestas

    2018-04-01

    Rape (Brassica napus L.) is a major global oilseed crop characterized by its high potential as an alimentary oil and in biodiesel production. The two most popular pod sealants (PS) used to reduce rape pod shattering are products in the pinolene range (di-1-p-menthene) and latex polymer products. Reports on the effective preservation of seed yield by these products are fairly contradictory. With this in mind, an experimental PS (PS4) that contained the active agents acrylic and trisiloxane was developed. Comparative experimental trials of the developed PS4 and three other PS (PS1, PS2 and PS3) containing active agents that are generally used for sealant production were conducted. The studies showed that the static and dynamic surface tension of PS4 was the lowest at the same concentration (2.0 g kg -1 ), consequently demonstrating the lowest spray drift. The chemical substances from PS had not penetrated the rape seeds in any of the PSs. The results indicate that treatment with PS4 exerts a beneficial effect in reducing rape seed yield loss (68-104 kg ha -1 in 2014 and 194-305 kg ha -1 in 2015) compared to other investigated PS. © 2017 Society of Chemical Industry. © 2017 Society of Chemical Industry.

  6. Collector sealants and breathing. Final Report, 25 September 1978-31 December 1979

    Energy Technology Data Exchange (ETDEWEB)

    Mendelsohn, M A; Luck, R M; Yeoman, F A; Navish, Jr, F W

    1980-02-20

    The objectives of this program were: (1) to investigate the pertinent properties of a variety of possible sealants for solar collectors and identify the most promising candidates, and (2) to study the effect of breathing in flat-plate, thermal solar collector units. The study involved two types of sealants, Class PS which includes preformed seals or gaskets and Class SC which includes sealing compounds or caulks. It was the intent of the study to obtain data regarding initial properties of candidate elastomers from manufacturers and from the technical literature and to use those sources to provide data pertaining to endurance of these materials under environmental service conditions. Where necessary, these data were augmented by experimental measurements. Environmental stresses evaluated by these measurements included elevated temperatures, moisture, ultraviolet light, ozone and oxygen, and fungus. The second major area of the work involved a study of the effects of materials used and design on the durability of solar collectors. Factors such as design, fabrication, materials of construction, seals and sealing techniques and absorber plate coatings were observed on actual field units removed from service. Such phenomena as leakage, corrosion and formation of deposits on glazing and absorber plate were noted. An evaluation of the properties of several desiccants was made in order to providemeans to mitigate the deleterious effects of water on collector life. Adsorbents for organic degradation products of sealants were also investigated in order to protect the glazing and absorber plate from deposited coatings. Since adsorbents and desiccants in general tend to take up both water and organic decomposition products, relative affinities of a number of these agents for water and for organic compounds were determined . Results are presented in detail.

  7. Injectible candidate sealants for fetal membrane repair: Bonding and toxicity in vitro

    Science.gov (United States)

    Bilic, Grozdana; Brubaker, Carrie; Messersmith, Phillip B.; Mallik, Ajit S.; Quinn, Thomas M.; Haller, Claudia; Done, Elisa; Gucciardo, Leonardo; Zeisberger, Steffen M.; Zimmermann, Roland; Deprest, Jan; Zisch, Andreas H.

    2010-01-01

    Objective This study was undertaken to test injectible surgical sealants that are biocompatible with fetal membranes, eventually for closure of iatrogenic membrane defects. Study Design Dermabond, Histoacryl, Tissucol fibrin glue, and three types of in situ forming poly(ethylene glycol)-based polymer hydrogels were tested for acute toxicity upon direct contact with fetal membranes for 24h. For determination of elution toxicity, extracts of sealants were incubated on amnion cell cultures for 72h. Bonding and toxicity was assessed through morphological and/or biochemical analysis. Results Extracts of all adhesives were non-toxic for cultured cells. However, only Tissucol and one type of poly(ethylene glycol)-based hydrogel, mussel-mimetic tissue adhesive, showed efficient, non-disruptive, non-toxic bonding to fetal membranes. Mussel-mimetic tissue adhesive applied over membrane defects created with a 3.5 mm trocar accomplished leak-proof closure that withstood membrane stretch in an in vitro model. Conclusion A synthetic hydrogel-type tissue adhesive emerged as potential sealing modality for iatrogenic membrane defects that merits further evaluation in vivo. PMID:20096254

  8. Wellbore Completion Systems Containment Breach Solution Experiments at a Large Scale Underground Research Laboratory : Sealant placement & scale-up from Lab to Field

    Science.gov (United States)

    Goodman, H.

    2017-12-01

    This investigation seeks to develop sealant technology that can restore containment to completed wells that suffer CO2 gas leakages currently untreatable using conventional technologies. Experimentation is performed at the Mont Terri Underground Research Laboratory (MT-URL) located in NW Switzerland. The laboratory affords investigators an intermediate-scale test site that bridges the gap between the laboratory bench and full field-scale conditions. Project focus is the development of CO2 leakage remediation capability using sealant technology. The experimental concept includes design and installation of a field scale completion package designed to mimic well systems heating-cooling conditions that may result in the development of micro-annuli detachments between the casing-cement-formation boundaries (Figure 1). Of particular interest is to test novel sealants that can be injected in to relatively narrow micro-annuli flow-paths of less than 120 microns aperture. Per a special report on CO2 storage submitted to the IPCC[1], active injection wells, along with inactive wells that have been abandoned, are identified as one of the most probable sources of leakage pathways for CO2 escape to the surface. Origins of pressure leakage common to injection well and completions architecture often occur due to tensile cracking from temperature cycles, micro-annulus by casing contraction (differential casing to cement sheath movement) and cement sheath channel development. This discussion summarizes the experiment capability and sealant testing results. The experiment concludes with overcoring of the entire mock-completion test site to assess sealant performance in 2018. [1] IPCC Special Report on Carbon Dioxide Capture and Storage (September 2005), section 5.7.2 Processes and pathways for release of CO2 from geological storage sites, page 244

  9. 40 CFR 63.6000 - How do I conduct tests and procedures for puncture sealant application affected sources?

    Science.gov (United States)

    2010-07-01

    ... Tire Manufacturing Testing and Initial Compliance Requirements for Puncture Sealant Application... balances to demonstrate compliance, if the storage of materials, exhaust, or the wastewater from more than...

  10. Effectiveness of fluoride sealant in the prevention of carious lesions around orthodontic brackets: an OCT evaluation

    Science.gov (United States)

    Pithon, Matheus Melo; Santos, Mariana de Jesus; de Souza, Camilla Andrade; Leão, Jorge César Borges; Braz, Ana Karla Souza; de Araujo, Renato Evangelista; Tanaka, Orlando Motohiro; Oliveira, Dauro Douglas

    2015-01-01

    Abstract Objective: This article aimed to evaluate in vitro the efficiency of Pro Seal fluoride sealant application in the prevention of white spot lesions around orthodontic brackets. Material and Methods: Brackets were bonded to the buccal surface of bovine incisors, and five groups were formed (n = 15) according to the exposure of teeth to oral hygiene substances and the application of enamel sealant: G1 (control), only brushing was performed with 1.450 ppm fluoride; G2 (control) brushing associated with the use of mouthwash with 225 ppm fluoride; G3, only Pro Seal sealant application was performed with 1.000 ppm fluoride; G4 Pro Seal associated with brushing; G5 Pro Seal associated with brushing and mouthwash. Experimental groups alternated between pH cycling and the procedures described. All specimens were kept at a temperature of 37 °C throughout the entire experiment. Both brushing and immersion in solutions were performed within a time interval of one minute, followed by washing in deionized water three times a day for 28 days. Afterwards, an evaluation by Optical Coherence Tomography (OCT) of the spectral type was performed. In each group, a scanning exam of the white spot lesion area (around the sites where brackets were bonded) and depth measurement of carious lesions were performed. Analysis of variance (ANOVA) was applied to determine whether there were significant differences among groups. For post hoc analysis, Tukey test was used. Results: There was statistically significant difference between groups 1 and 2 (p = 0.003), 1 and 3 (p = 0.008), 1 and 4 (p = 0.000) and 1 and 5 (p = 0.000). The group in which only brushing was performed (Group 1) showed deeper enamel lesion. Conclusion: Pro Seal sealant alone or combined with brushing and/or brushing and the use of a mouthwash with fluoride was more effective in protecting enamel, in comparison to brushing alone. PMID:26691968

  11. Two-year survival of glass ionomer sealanTs placed as parT of ...

    African Journals Online (AJOL)

    2010-09-09

    Sep 9, 2010 ... Two-year survival of glass ionomer sealanTs placed as parT of proximal aTraumaTic. resToraTive ... absTracT. Objective: To evaluate after two years, the survival rate of glass ionomer cement (gic) ... or symptoms of periodontal disease, and clinically the ..... saliva contamination on the bond of dentine resin-.

  12. A Test Method for Monitoring Modulus Changes during Durability Tests on Building Joint Sealants

    Science.gov (United States)

    Christopher C. White; Donald L. Hunston; Kar Tean Tan; Gregory T. Schueneman

    2012-01-01

    The durability of building joint sealants is generally assessed using a descriptive methodology involving visual inspection of exposed specimens for defects. It is widely known that this methodology has inherent limitations, including that the results are qualitative. A new test method is proposed that provides more fundamental and quantitative information about...

  13. Parents' Attitude towards the Use of Fluorides and Fissure Sealants and its Effect on their Children's Oral Health.

    Science.gov (United States)

    Blumer, Sigalit; Ratson, Tal; Peretz, Benjamin; Dagon, Nurit

    To characterize the attitudes of Israeli parents towards caries preventive measures. participating parents completed a 21-item questionnaire on their demographics, dental history, attitudes and satisfaction from fluorides and fissure sealants. One hundred parents (average age 41.62±4.9 years, 85 females) participated. Most of the parents (88% of the mothers and 84% of the fathers) had an academic education. Most of the parents (54%) had a favorable attitude towards the use of fluoridated gels, while only 37% of them had a positive opinion regarding fluoridated water. The satisfaction levels were very high regarding fissure sealants, fluoridated mouth rinses and fluoridated gels (78.1%, 73.6% and 72.5% respectively). The satisfaction from fluoridated water was split almost equally (50.8% were 'pleased' and 49.2% 'not pleased'). The main source for parental oral health knowledge was the dentist (83%). Parents' attitude towards caries preventive measures was significantly correlated to their gender, dental experience, level of education and the number of children in the family. positive attitude towards caries preventive measures was found among parents with higher awareness for preventive oral health measures and among bigger families. Mothers were more positive about fissure sealants than fathers. Mothers with up to 12 years of education tended to have a positive opinion regarding water fluoridation.

  14. Enamel pretreatment with Er:YAG laser: effects on the microleakage of fissure sealant in fluorosed teeth

    Directory of Open Access Journals (Sweden)

    Mahtab Memarpour,

    2014-08-01

    Full Text Available Objectives The purpose of this in vitro study was to evaluate the microleakage and penetration of fissure sealant in permanent molar teeth with fluorosis after pretreatment of the occlusal surface. Materials and Methods A total of 120 third molars with mild dental fluorosis were randomly divided into 6 groups (n = 20. The tooth surfaces were sealed with an unfilled resin fissure sealant (FS material. The experimental groups included: 1 phosphoric acid etching (AE + FS (control; 2 AE + One-Step Plus (OS, Bisco + FS; 3 bur + AE + FS; 4 bur + AE + OS + FS; 5 Er:YAG laser + AE + FS; and 6 Er:YAG laser + AE + OS + FS. After thermocycling, the teeth were immersed in 0.5% fuchsin and sectioned. Proportions of mircoleakage (PM and unfilled area (PUA were measured by digital microscope. Results Overall, there were significant differences among all groups in the PM (p = 0.00. Group 3 showed the greatest PM, and was significantly different from groups 2 to 6 (p < 0.05. Group 6 showed the lowest PM. Pretreatment with Er:YAG with or without adhesive led to less PM than bur pretreatment. There were no significant differences among groups in PUA. Conclusions Conventional acid etching provided a similar degree of occlusal seal in teeth with fluorosis compared to those pretreated with a bur or Er:YAG laser. Pretreatment of pits and fissures with Er:YAG in teeth with fluorosis may be an alternative method before fissure sealant application.

  15. A Systematic Approach to the Study of Accelerated weathering of Building Joint Sealants

    Science.gov (United States)

    Christopher C. White; Donald L. Hunston; Kar Tean Tan; James J. Filliben; Adam L. Pintar; Greg. Schueneman

    2012-01-01

    An accurate service life prediction model is needed for building joint sealants in order to greatly reduce the time to market of a new product and reduce the risk of introducing a poorly performing product into the marketplace. A stepping stone to the success of this effort is the precise control of environmental variables in a laboratory accelerated test apparatus in...

  16. Resistência ao cisalhamento de um selante associado a componentes de um sistema adesivo dental Shear bond strength of an enamel sealant using components of a dental adhesive system

    Directory of Open Access Journals (Sweden)

    Zilda Maria MUSSOLINO

    1998-10-01

    Full Text Available Cilindros de selante, padronizados, foram unidos ao esmalte das superfícies vestibulares de incisivos bovinos, após serem planificadas e condicionadas, com ácido fosfórico a 37%, durante 30 segundos. Foram utilizados 40 dentes, aleatoriamente divididos em 4 grupos, cujas coroas foram secionadas, de modo a obter-se duas porções, cervical e incisal. No Grupo I, após o condicionamento, aplicou-se o selante Fluroshield; no Grupo II, antes da aplicação do selante, uma camada do "primer" do Probond foi aplicada; no Grupo III, após o "primer", aplicou-se o adesivo do Probond; e no Grupo IV, somente o adesivo foi aplicado antes do selante. Os espécimes foram armazenados em água a 37°C, durante 36 horas, e então submetidos aos ensaios de cisalhamento. A análise estatística revelou significante diminuição na resistência ao cisalhamento, quando o "primer" foi aplicado previamente ao selante, enquanto a resistência ao cisalhamento do selante foi semelhante quando o adesivo do Probond foi aplicado, com ou sem o "primer". A resistência ao cisalhamento do selante ao esmalte é maior no terço incisal que no terço cervical da coroa.Standardized cylinders of sealants were bonded to the flattened labial enamel of bovine incisor teeth that had previously been subjected to 37% phosphoric acid gel for 30 seconds. A total of 40 teeth were tested, randomly divided in four groups of 10 teeth each. In Group I, the sealant Fluroshield was applied after etching; in Group II after etching, the "primer" of Probond was used before the sealant; in Group III after etching, the bond of Probond was used after the "primer"; and in Group IV only the bond was applied before the sealant. Specimens were stored in water at 37°C during 36 hours, before shear testing using a Universal Testing Machine. There was significant reduction in shear bond strength of the sealant when only the "primer" was used previously to the application of the sealant. There were no

  17. Cost-effectiveness, in a randomized trial, of glass-ionomer-based and resin sealant materials after 4 yr

    NARCIS (Netherlands)

    Goldman, A.S.; Chen, X.; Fan, M.; Frencken, J.E.

    2016-01-01

    This study, conducted from a government program perspective, compared the incremental cost-effectiveness of oral health interventions, in particular their delivery to underserved populations in whom dental sealants constitute an important, high-yielding complement to toothbrushing in dental-caries

  18. A case history on long-term effectiveness of clay sealant

    International Nuclear Information System (INIS)

    Lee, C.F.

    1986-01-01

    This report documents a case history in which a cadaver and the associated burial objects were found to be well-preserved after more than 2100 years of burial in Southern China. The preservation was attributed to the presence of a 60-300 cm thick kaolin or white clay layer around the tomb, which acted effectively as a barrier to moisture and air percolation. The degree of preservation in other tombs of similar age in the same area apparently depended on the mineralogy and thickness of the clay sealants used. The implication of this case history to nuclear fuel waste disposal is discussed

  19. Validation of micro-CT against the section method regarding the assessment of marginal leakage of sealants.

    NARCIS (Netherlands)

    Chen, X.; Cuijpers, V.M.J.I.; Fan, M.W.; Frencken, J.E.F.M.

    2012-01-01

    BACKGROUND: The aim of this study was to validate the micro-CT and related software against the section method using the stereomicroscope for marginal leakage assessment along the sealant-enamel interface. METHODS: Pits and fissures of the occlusal surface of 10 teeth were sealed with a

  20. A Comparative Evaluation of the Effect of Bonding Agent on the Tensile Bond Strength of Two Pit and Fissure Sealants Using Invasive and Non-invasive Techniques: An in-vitro Study.

    Science.gov (United States)

    Singh, Shamsher; Adlakha, Vivek; Babaji, Prashant; Chandna, Preetika; Thomas, Abi M; Chopra, Saroj

    2013-10-01

    Newer technologies and the development of pit and fissure sealants have shifted the treatment philosophy from 'drill and fill' to that of 'seal and heal'. The purpose of this in-vitro study was to evaluate the effects of bonding agents on the tensile bond strengths of two pit and fissure sealants by using invasive and non-invasive techniques. One hundred and twenty bicuspids were collected and teeth were divided into two groups: Group-I (Clinpro) and Group-II (Conseal f) with 60 teeth in each group. For evaluating tensile bond strengths, occlusal surfaces of all the teeth were flattened by reducing buccal and lingual cusps without disturbing fissures. Standardised polyvinyl tube was bonded to occlusal surfaces with respective materials. Sealants were applied, with or without bonding agents, in increments and they were light cured. Tensile bond strengths were determined by using Universal Testing Machine. Data were then statistically analysed by using Student t-test for comparison. A statistically significant difference was found in tensile bond strength in invasive with bonding agent group than in non-invasive with bonding agent group. This study revealed that invasive techniques increase the tensile bond strengths of sealants as compared to non- invasive techniques and that the use of a bonding agent as an intermediate layer between the tooth and fissure sealant is beneficial for increasing the bond strength.

  1. Successful conservative treatment of enterocutaneous fistula with cyanoacrylate surgical sealant: case report.

    Science.gov (United States)

    Musa, N; Aquilino, F; Panzera, P; Martines, G

    2017-01-01

    Enterocutaneous (EC) fistula is an abnormal communication between the gastrointestinal tract and the skin. The majority of EC fistulas result from surgery. Only 15-25% of EC fistulas are spontaneous and they often result from underlying diseases such as Crohn's disease, radiation and chemotherapy. A 62-year old woman who, in 2012, underwent Pylorus-preserving cephalic pancreaticoduodenectomy (PPPD sec. Traverso-Longmire), due to an advanced pancreatic ductal adenocarcinoma (pT3N1M1). After surgery, the patient underwent chemotherapy with folfirinox regimen. In December 2016, as a result of the appearance of metastatic liver lesions and perianastomotic recurrence, the patient underwent second line treatment with Gemcitabine and pab-paclitaxel. After five months from the beginning of this new second line therapy she presented an EC fistula. The fistula of the patient was successfully treated with total parenteral nutrition and with percutaneous injection of cyanoacrylic sealant. The result suggests the advisability of percutaneous injection of sealant devices, such as cyanoacrylate glue; in order to successfully control stable Enterocutaneous fistulas with acceptable morbidity and mortality especially in particular situations, such as, with low output EC fistulas without signs of complications or on patients considered not suitable for surgery, a conservative approach could ensure the control of the fistula. This approach is easy and safe, viable and useful for future trials on the efficacy in conservative treatment of EC fistula.

  2. Motor recovery and synaptic preservation after ventral root avulsion and repair with a fibrin sealant derived from snake venom.

    Directory of Open Access Journals (Sweden)

    Roberta Barbizan

    Full Text Available BACKGROUND: Ventral root avulsion is an experimental model of proximal axonal injury at the central/peripheral nervous system interface that results in paralysis and poor clinical outcome after restorative surgery. Root reimplantation may decrease neuronal degeneration in such cases. We describe the use of a snake venom-derived fibrin sealant during surgical reconnection of avulsed roots at the spinal cord surface. The present work investigates the effects of this fibrin sealant on functional recovery, neuronal survival, synaptic plasticity, and glial reaction in the spinal motoneuron microenvironment after ventral root reimplantation. METHODOLOGY/PRINCIPAL FINDINGS: Female Lewis rats (7 weeks old were subjected to VRA and root replantation. The animals were divided into two groups: 1 avulsion only and 2 replanted roots with fibrin sealant derived from snake venom. Post-surgical motor performance was evaluated using the CatWalk system twice a week for 12 weeks. The rats were sacrificed 12 weeks after surgery, and their lumbar intumescences were processed for motoneuron counting and immunohistochemistry (GFAP, Iba-1 and synaptophysin antisera. Array based qRT-PCR was used to evaluate gene regulation of several neurotrophic factors and receptors as well as inflammatory related molecules. The results indicated that the root reimplantation with fibrin sealant enhanced motor recovery, preserved the synaptic covering of the motoneurons and improved neuronal survival. The replanted group did not show significant changes in microglial response compared to VRA-only. However, the astroglial reaction was significantly reduced in this group. CONCLUSIONS/SIGNIFICANCE: In conclusion, the present data suggest that the repair of avulsed roots with snake venom fibrin glue at the exact point of detachment results in neuroprotection and preservation of the synaptic network at the microenvironment of the lesioned motoneurons. Also such procedure reduced the

  3. Motor Recovery and Synaptic Preservation after Ventral Root Avulsion and Repair with a Fibrin Sealant Derived from Snake Venom

    Science.gov (United States)

    Barbizan, Roberta; Castro, Mateus V.; Rodrigues, Antônio C.; Barraviera, Benedito; Ferreira, Rui S.; Oliveira, Alexandre L. R.

    2013-01-01

    Background Ventral root avulsion is an experimental model of proximal axonal injury at the central/peripheral nervous system interface that results in paralysis and poor clinical outcome after restorative surgery. Root reimplantation may decrease neuronal degeneration in such cases. We describe the use of a snake venom-derived fibrin sealant during surgical reconnection of avulsed roots at the spinal cord surface. The present work investigates the effects of this fibrin sealant on functional recovery, neuronal survival, synaptic plasticity, and glial reaction in the spinal motoneuron microenvironment after ventral root reimplantation. Methodology/Principal Findings Female Lewis rats (7 weeks old) were subjected to VRA and root replantation. The animals were divided into two groups: 1) avulsion only and 2) replanted roots with fibrin sealant derived from snake venom. Post-surgical motor performance was evaluated using the CatWalk system twice a week for 12 weeks. The rats were sacrificed 12 weeks after surgery, and their lumbar intumescences were processed for motoneuron counting and immunohistochemistry (GFAP, Iba-1 and synaptophysin antisera). Array based qRT-PCR was used to evaluate gene regulation of several neurotrophic factors and receptors as well as inflammatory related molecules. The results indicated that the root reimplantation with fibrin sealant enhanced motor recovery, preserved the synaptic covering of the motoneurons and improved neuronal survival. The replanted group did not show significant changes in microglial response compared to VRA-only. However, the astroglial reaction was significantly reduced in this group. Conclusions/Significance In conclusion, the present data suggest that the repair of avulsed roots with snake venom fibrin glue at the exact point of detachment results in neuroprotection and preservation of the synaptic network at the microenvironment of the lesioned motoneurons. Also such procedure reduced the astroglial reaction and

  4. 40 CFR Table 3 to Subpart Xxxx of... - Emission Limits for Puncture Sealant Application Affected Sources

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 12 2010-07-01 2010-07-01 true Emission Limits for Puncture Sealant Application Affected Sources 3 Table 3 to Subpart XXXX of Part 63 Protection of Environment ENVIRONMENTAL... Manufacturing Pt. 63, Subpt. XXXX, Table 3 Table 3 to Subpart XXXX of Part 63—Emission Limits for Puncture...

  5. 40 CFR Table 4 to Subpart Xxxx of... - Operating Limits for Puncture Sealant Application Control Devices

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 12 2010-07-01 2010-07-01 true Operating Limits for Puncture Sealant Application Control Devices 4 Table 4 to Subpart XXXX of Part 63 Protection of Environment ENVIRONMENTAL... Manufacturing Pt. 63, Subpt. XXXX, Table 4 Table 4 to Subpart XXXX of Part 63—Operating Limits for Puncture...

  6. Fissure sealants in caries prevention:a practice-based study using survival analysis

    OpenAIRE

    Leskinen, K. (Kaja)

    2010-01-01

    Abstract The purpose of this study was to analyse the effectiveness and cost of fissure sealant treatment in preventing dental caries in children in a practice-based research network using survival analysis. The survival times of first permanent molars in children were analysed in three countries: in Finland (age cohorts 1970–1972 and 1980–1982), in Sweden (1980–1982) and in Greece (1980–1982), and additionally at two municipal health centres in Finland (age cohorts 1988–1990 in Kemi...

  7. Analysing uncertainty around costs of innovative medical technologies: the case of fibrin sealant (QUIXIL) for total knee replacement.

    NARCIS (Netherlands)

    Steuten, Lotte Maria Gertruda; Vallejo-Torres, Laura; Bastide, Philippe; Buxton, Martin J.

    2009-01-01

    This paper presents a relatively simple cost model comparing the costs of using a commercial fibrin sealant (QUIXIL®) in addition to conventional haemostatic treatment vs. conventional treatment alone in total knee replacement (TKR) surgery, and demonstrates and discusses how one- and two-way

  8. Evaluation of Fibrin Sealants and Tissue Adhesives in Oral Surgery for Patients with Bleeding Disorders

    Directory of Open Access Journals (Sweden)

    Gülsüm Ak

    2012-03-01

    Full Text Available OBJECTIVE: The aim of this study was to evaluate the efficiency of two local haemostatic agents administered together with preoperative dose of replacement therapy for oral surgical procedures in patients with bleeding disorders METHODS: Twenty-one patients were divided into three groups randomly. Patients in Group 1 (n=7 received preoperative replacement therapy with postoperative fibrin sealant application in the surgical site. Patients in Group 2 (n=7 received preoperative replacement therapy with postoperative tissue adhesive application in the surgical site. Patients in Group 3 (n=7 were given total dose of replacement therapy pre- and postoperatively. RESULTS: No postoperative bleeding was observed in 17 patients including five patients in Group 1 (71.42%, six patients in Group 2 (85.71% and six patients in Group 3 (85.71%. Haemorrhagic complication was observed in only four patients among all groups. CONCLUSION: We conclude that utilization of fibrin sealants and tissue adhesives in oral surgery is beneficial due to the lessened amount of factor concentrates used for replacement therapy and the rapid haemostasis at the operation side to perform serial surgical procedures in the same session.

  9. Dextran/Albumin hydrogel sealant for Dacron(R) vascular prosthesis.

    Science.gov (United States)

    Lisman, Anna; Butruk, Beata; Wasiak, Iga; Ciach, Tomasz

    2014-05-01

    In this paper, the authors describe a novel type of hydrogel coating prepared from the copolymer of human serum albumin and oxidized dextran. The material was designed as a hydrogel sealant for polyester (Dacron®)-based vascular grafts. Dextran was chosen as a coating material due to its anti-thrombogenic properties. Prepared hydrogels were compared with similar, already known biomaterial made from gelatine with the same cross-linking agent. Obtained hydrogels, prepared from various ratios of oxidized dextran/albumin or oxidized dextran/gelatine, showed different cross-linking densities, which caused differences in swelling, degradation rate and mechanical properties. Permeability tests confirmed the complete tightness of the hydrogel-modified prosthesis. Results showed that application of the hydrogel coating provided leakage-free prosthesis and eliminated the need of pre-clotting.

  10. Applying psychological theories to evidence-based clinical practice: identifying factors predictive of placing preventive fissure sealants.

    Science.gov (United States)

    Bonetti, Debbie; Johnston, Marie; Clarkson, Jan E; Grimshaw, Jeremy; Pitts, Nigel B; Eccles, Martin; Steen, Nick; Thomas, Ruth; Maclennan, Graeme; Glidewell, Liz; Walker, Anne

    2010-04-08

    Psychological models are used to understand and predict behaviour in a wide range of settings, but have not been consistently applied to health professional behaviours, and the contribution of differing theories is not clear. This study explored the usefulness of a range of models to predict an evidence-based behaviour -- the placing of fissure sealants. Measures were collected by postal questionnaire from a random sample of general dental practitioners (GDPs) in Scotland. Outcomes were behavioural simulation (scenario decision-making), and behavioural intention. Predictor variables were from the Theory of Planned Behaviour (TPB), Social Cognitive Theory (SCT), Common Sense Self-regulation Model (CS-SRM), Operant Learning Theory (OLT), Implementation Intention (II), Stage Model, and knowledge (a non-theoretical construct). Multiple regression analysis was used to examine the predictive value of each theoretical model individually. Significant constructs from all theories were then entered into a 'cross theory' stepwise regression analysis to investigate their combined predictive value. Behavioural simulation - theory level variance explained was: TPB 31%; SCT 29%; II 7%; OLT 30%. Neither CS-SRM nor stage explained significant variance. In the cross theory analysis, habit (OLT), timeline acute (CS-SRM), and outcome expectancy (SCT) entered the equation, together explaining 38% of the variance. Behavioural intention - theory level variance explained was: TPB 30%; SCT 24%; OLT 58%, CS-SRM 27%. GDPs in the action stage had significantly higher intention to place fissure sealants. In the cross theory analysis, habit (OLT) and attitude (TPB) entered the equation, together explaining 68% of the variance in intention. The study provides evidence that psychological models can be useful in understanding and predicting clinical behaviour. Taking a theory-based approach enables the creation of a replicable methodology for identifying factors that may predict clinical behaviour

  11. Assessment of Pain and Quality of Life in Lichtenstein Hernia Repair Using a New Monofilament PTFE Mesh: Comparison of Suture vs. Fibrin-Sealant Mesh Fixation.

    Science.gov (United States)

    Fortelny, René H; Petter-Puchner, Alexander H; Redl, Heinz; May, Christopher; Pospischil, Wolfgang; Glaser, Karl

    2014-01-01

    Inguinal hernia repair is one of the most common operations in general surgery. The Lichtenstein tension-free operation has become the gold standard in open inguinal hernia repair. Despite the low recurrence rates, pain and discomfort remain a problem for a large number of patients. The aim of this study was to compare suture fixation vs. fibrin sealing by using a new monofilament PTFE mesh, i.e., the Infinit(®) mesh by W. L. Gore & Associates. This study was designed as a controlled prospective single-center two-cohort study. A total of 38 patients were enrolled and operated in Lichtenstein technique either standard suture mesh fixation or fibrin-sealant mesh fixation were used as described in the TIMELI trial. Primary outcome parameters were postoperative complications with the new mesh (i.e., seroma, infection), pain, and quality of life evaluated by the VAS and the SF-36 questionnaire. Secondary outcome was recurrence assessed by ultrasound and physical examination. Follow-up time was 1 year. Significantly, less postoperative pain was reported in the fibrin-sealant group compared to the suture group at 6 weeks (P = 0.035), 6 months (P = 0.023), and 1 year (P = 0.011) postoperatively. Additionally, trends toward a higher postoperative quality of life, a faster surgical procedure, and a shorter hospital stay were seen in the fibrin-sealant group. Fibrin-sealant mesh fixation in Lichtenstein hernioplasty effectively reduces acute and chronic postoperative pain. Monofilament, macro-porous, knitted PTFE meshes seem to be a practicable alternative to commonly used polypropylene meshes in open inguinal hernia repair.

  12. Assessment of pain and quality of life in Lichtenstein hernia repair using a new monofilament PTFE mesh: comparison of suture vs. fibrin sealant mesh fixation

    Directory of Open Access Journals (Sweden)

    René H Fortelny

    2014-11-01

    Full Text Available Background: Inguinal hernia repair is one of the most common operations in general surgery. The Lichtenstein tension-free operation has become the gold standard in open inguinal hernia repair. Despite the low recurrence rates, pain and discomfort remain a problem for a large number of patients. The aim of this study was to compare suture fixation vs. fibrin sealing by using a new monofilament PTFE mesh, i.e. the Infinit® mesh by W. L. Gore & Associates. Methods: This study was designed as a controlled prospective single-centre two cohort study. A total of 38 patients were enrolled and operated in Lichtenstein technique either standard suture mesh fixation or fibrin sealant mesh fixation were used as described in the TIMELI trial. Primary outcome parameters were postoperative complications with the new mesh (i.e. seroma, infection, pain and quality of life evaluated by the VAS and the SF-36 questionnaire. Secondary outcome was recurrence assessed by ultrasound and physical examination. Follow-up time was 1 year.Results: Significantly less postoperative pain was reported in the fibrin sealant group compared to the suture group at 6 weeks (P=0.035, 6 months (P=0.023 and 1 year (P=0.011 postoperatively. Additionally trends towards a higher postoperative quality of life, a faster surgical procedure and a shorter hospital stay were seen in the fibrin sealant group.Conclusion: Fibrin sealant mesh fixation in Lichtenstein hernioplasty effectively reduces acute and chronic postoperative pain. Monofilament, macro-porous, knitted PTFE meshes seem to be a practicable alternative to commonly used polypropylene meshes in open inguinal hernia repair.

  13. 40 CFR Table 14 to Subpart Xxxx of... - Continuous Compliance With the Emission Limitations for Puncture Sealant Application Affected...

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 12 2010-07-01 2010-07-01 true Continuous Compliance With the Emission Limitations for Puncture Sealant Application Affected Sources 14 Table 14 to Subpart XXXX of Part 63... Hazardous Air Pollutants: Rubber Tire Manufacturing Pt. 63, Subpt. XXXX, Table 14 Table 14 to Subpart XXXX...

  14. Influence of surface sealant on the translucency of composite resin: effect of immersion time and immersion media

    Directory of Open Access Journals (Sweden)

    Patrícia Petromilli Nordi Sasso Garcia

    2008-06-01

    Full Text Available This study evaluated the effect of surface sealant on the translucency of composite resin immersed in different solutions. The study involved the following materials: Charisma, Fortify and coffee, Coca-Cola®, tea and artificial saliva as solutions. Sixty-four specimens (n = 8 were manufactured and immersed in artificial saliva at 37 ± 1 °C. Samples were immersed in the solutions for three times a day and re-immersed in artificial saliva until the translucency readings. The measurements were carried out at nine times: T1 - 24 hours after specimen preparation, T2 - 24 hours after immersion in the solutions, T3 - 48 hours and T4 to T9 - 7, 14, 21, 30, 60 and 90 days, respectively, after immersion. The translucency values were measured using a JOUAN device. The results were subjected to ANOVA and Tukey's test at 5%. The surface sealant was not able to protect the composite resin against staining, the coffee showed the strongest staining action, followed by tea and regarding immersion time, a significant alteration was noted in the translucency of composite resin after 21 days.

  15. Autologous fibrin sealant reduces the incidence of prolonged air leak and duration of chest tube drainage after lung volume reduction surgery: a prospective randomized blinded study.

    Science.gov (United States)

    Moser, C; Opitz, I; Zhai, W; Rousson, V; Russi, E W; Weder, W; Lardinois, D

    2008-10-01

    Prolonged air leak is reported in up to 50% of patients after lung volume reduction surgery. The effect of an autologous fibrin sealant on the intensity and duration of air leak and on the time to chest drain removal after lung volume reduction surgery was investigated in a randomized prospective clinical trial. Twenty-five patients underwent bilateral thoracoscopic lung volume reduction surgery. In each patient, an autologous fibrin sealant was applied along the staple lines on one side, whereas no additional measure was taken on the other side. Randomization of treatment was performed at the end of the resection on the first side. Air leak was assessed semiquantitatively by use of a severity score (0 = no leak; 4 = continuous severe leak) by two investigators blinded to the treatment. Mean value of the total severity scores for the first 48 hours postoperative was significantly lower in the treated group (4.7 +/- 7.7) than in the control group (16.0 +/- 10.1) (P drainage were also significantly reduced after application of the sealant (4.5% and 2.8 +/- 1.9 days versus 31.8% and 5.9 +/- 2.9 days) (P = .03 and P drainage.

  16. Applying psychological theories to evidence-based clinical practice: identifying factors predictive of placing preventive fissure sealants

    Directory of Open Access Journals (Sweden)

    Maclennan Graeme

    2010-04-01

    Full Text Available Abstract Background Psychological models are used to understand and predict behaviour in a wide range of settings, but have not been consistently applied to health professional behaviours, and the contribution of differing theories is not clear. This study explored the usefulness of a range of models to predict an evidence-based behaviour -- the placing of fissure sealants. Methods Measures were collected by postal questionnaire from a random sample of general dental practitioners (GDPs in Scotland. Outcomes were behavioural simulation (scenario decision-making, and behavioural intention. Predictor variables were from the Theory of Planned Behaviour (TPB, Social Cognitive Theory (SCT, Common Sense Self-regulation Model (CS-SRM, Operant Learning Theory (OLT, Implementation Intention (II, Stage Model, and knowledge (a non-theoretical construct. Multiple regression analysis was used to examine the predictive value of each theoretical model individually. Significant constructs from all theories were then entered into a 'cross theory' stepwise regression analysis to investigate their combined predictive value Results Behavioural simulation - theory level variance explained was: TPB 31%; SCT 29%; II 7%; OLT 30%. Neither CS-SRM nor stage explained significant variance. In the cross theory analysis, habit (OLT, timeline acute (CS-SRM, and outcome expectancy (SCT entered the equation, together explaining 38% of the variance. Behavioural intention - theory level variance explained was: TPB 30%; SCT 24%; OLT 58%, CS-SRM 27%. GDPs in the action stage had significantly higher intention to place fissure sealants. In the cross theory analysis, habit (OLT and attitude (TPB entered the equation, together explaining 68% of the variance in intention. Summary The study provides evidence that psychological models can be useful in understanding and predicting clinical behaviour. Taking a theory-based approach enables the creation of a replicable methodology for

  17. Detection of occlusal caries with impedance spectroscopy and laser fluorescence before and after placement of fissure sealants: An in vitro study

    DEFF Research Database (Denmark)

    Mortensen, Diana; Ekstrand, Kim; Twetman, Svante

    2016-01-01

    , the DIAGNOdent pen and ICDAS at baseline, after bleaching, etching and placement of a clear fissure sealant. A digital radiograph was exposed at baseline. After the assessments, the actual lesion depth was histologically determined.  Results : Bleaching did not affect the readings but significantly higher ACIS...

  18. Characterization of Fast-Scan Cyclic Voltammetric Electrodes Using Paraffin as an Effective Sealant with In Vitro and In Vivo Applications.

    Science.gov (United States)

    Ramsson, Eric S; Cholger, Daniel; Dionise, Albert; Poirier, Nicholas; Andrus, Avery; Curtiss, Randi

    2015-01-01

    Fast-scan cyclic voltammetry (FSCV) is a powerful technique for measuring sub-second changes in neurotransmitter levels. A great time-limiting factor in the use of FSCV is the production of high-quality recording electrodes; common recording electrodes consist of cylindrical carbon fiber encased in borosilicate glass. When the borosilicate is heated and pulled, the molten glass ideally forms a tight seal around the carbon fiber cylinder. It is often difficult, however, to guarantee a perfect seal between the glass and carbon. Indeed, much of the time spent creating electrodes is in an effort to find a good seal. Even though epoxy resins can be useful in this regard, they are irreversible (seals are permanent), wasteful (epoxy cannot be reused once hardener is added), hazardous (hardeners are often caustic), and require curing. Herein we characterize paraffin as an electrode sealant for FSCV microelectrodes. Paraffin boasts the advantages of near-immediate curing times, simplicity in use, long shelf-life and stable waterproof seals capable of withstanding extended cycling. Borosilicate electrode tips were left intact or broken and dipped in paraffin embedding wax. Excess wax was removed from the carbon surface with xyelenes or by repeated cycling at an extended waveform (-0.4 to 1.4V, 400 V/s, 60 Hz). Then, the waveform was switched to a standard waveform (-0.4 to 1.3V, 400 V/s, 10 Hz) and cycled until stable. Wax-sealing does not inhibit electrode sensitivity, as electrodes detected linear changes in dopamine before and after wax (then xylenes) exposure. Paraffin seals are intact after 11 days of implantation in the mouse, and still capable of measuring transient changes in in vivo dopamine. From this it is clear that paraffin wax is an effective sealant for FSCV electrodes that provides a convenient substitute to epoxy sealants.

  19. Coal-tar pavement sealants might substantially increase children's PAH exposures

    Science.gov (United States)

    Williams, E. Spencer; Mahler, Barbara J.; Van Metre, Peter C.

    2012-01-01

    Dietary ingestion has been identified repeatedly as the primary route of human exposure to polycyclic aromatic hydrocarbons (PAHs), seven of which are classified as probable human carcinogens (B2 PAHs) by the U.S. EPA. Humans are exposed to PAHs through ingestion of cooked and uncooked foods, incidental ingestion of soil and dust, inhalation of ambient air, and absorption through skin. Although PAH sources are ubiquitous in the environment, one recently identified PAH source stands out: Coal-tar-based pavement sealant—a product applied to many parking lots, driveways, and even playgrounds primarily in the central, southern, and eastern U.S.—has PAH concentrations 100–1000 times greater than most other PAH sources. It was reported recently that PAH concentrations in house dust in residences adjacent to parking lots with coal-tar-based sealant were 25 times higher than in residences adjacent to unsealed asphalt parking lots.

  20. Avaliação clínica de uma resina composta modificada por poliácido, utilizada como selante oclusal, quando aplicada por dentista, THD e graduando Clinical evaluation of a polyacid-modified resin composite, used as an occlusal sealant, when applied by dentist, dental hygienist and undergraduate

    Directory of Open Access Journals (Sweden)

    Roberta Tarkany BASTING

    1999-04-01

    Full Text Available O presente trabalho tem por finalidade comparar as diferenças de retenção de uma resina composta modificada por poliácido (Variglass V.L.C., utilizada como selante oclusal, quando aplicada por dentista, THD e graduando em Odontologia. Foram seladas as superfícies oclusais de 370 primeiros molares permanentes superiores de crianças entre 6 e 8 anos de idade provenientes de escolas públicas do município de Piracicaba. As avaliações clínicas foram realizadas após seis e oito meses da aplicação do selante. Aos seis meses, verificou-se que 78,42% dos selantes clinicamente aceitáveis permaneceram retidos sobre a superfície oclusal. O índice de perdas totais corresponderam a 10,20% do total de selantes aplicados. O melhor índice de retenção total foi obtido quando aplicado por graduando. Aos 12 meses, houve um aumento do número de selantes perdidos (43,79% e conseqüente decréscimo do número de selantes totalmente retidos (18,96%, não havendo diferenças significativas de retenção do selante quando aplicado por dentista, THD e graduando. Nos casos de perdas totais do selante, não se constatou presença de lesão cariosa.The aim of this work is to evaluate the differences of clinical retention of a polyacid-modified resin composite (Variglass V.L.C., used as an occlusal sealant, when applied by dentist, dental hygienist and undergraduate in Dentistry. The occlusal surfaces of 370 superior first molars of children ageing from 6 to 8 years from public schools in Piracicaba, were sealed. The presented data are related to the final evaluation after 6 and 12 months. It was observed that after 6 months, 78.42% of the sealants clinically acceptable, remained on the occlusal surfaces and that the completely lost sealants reached 10.20%. The best results of the sealants retention were obtained when the sealants were applied by an undergraduate. After 12 months, there was an increase of completely lost sealants (43.79% and a decrease of

  1. A comparison of the effect of short-acting and long-acting cloxacillin-based dry-cow therapy on somatic cell counts after calving in cows also given internal teat sealants.

    Science.gov (United States)

    Whitfield, L K; Laven, R A

    2018-01-01

    To compare, in cows treated with an internal teat sealant, the effect of short-acting and long-acting cloxacillin-based dry-cow therapy on somatic cell counts (SCC) after calving. Cows from a spring-calving, pasture-based dairy farm in the Manawatu-Whanganui region of New Zealand were randomly allocated to receive either a short-acting cloxacillin and ampicillin dry-cow therapy and internal teat sealant (n=291) or a long-acting cloxacillin and ampicillin dry-cow therapy and internal teat sealant (n=288) at the end of lactation. Cows were managed on-farm with routine husbandry procedures through the dry period and following calving. A multivariable logistic regression model was used to determine the association between length of action of dry-cow therapy and the proportion of cows with a SCC >150,000 cells/mL at the first herd test after calving. Age of cow, mean SCC for the preceding season and interval from calving to the first post-calving herd test were all associated with the proportion of cows with an individual SCC >150,000 cells/mL at the first herd test (pcow therapy was not associated with decreased odds of cows having a SCC >150,000 cells/mL at the first herd test compared with treatment with long-acting dry-cow therapy (OR=0.724; 95% CI=0.40-1.30). In this herd, which routinely used internal teat sealants, the use of short-acting cloxacillin-based dry-cow therapy did not result in an increased proportion of cows with elevated SSC post-calving. This was a single farm, single year study but indicates that in this herd, changing from a long-acting to a short-acting antimicrobial may have no impact on the prevalence of subclinical mastitis.

  2. Bond strength of a pit-and-fissure sealant associated to etch-and-rinse and self-etching adhesive systems to saliva-contaminated enamel: individual vs. simultaneous light curing.

    Science.gov (United States)

    Gomes-Silva, Jaciara Miranda; Torres, Carolina Paes; Contente, Marta Maria Martins Giamatei; Oliveira, Maria Angélica Hueb de Menezes; Palma-Dibb, Regina Guenka; Borsatto, Maria Cristina

    2008-01-01

    This study evaluated in vitro the shear bond strength (SBS) of a resin-based pit-and-fissure sealant [Fluroshield (F), Dentsply/Caulk] associated with either an etch-and-rinse [Adper Single Bond 2 (SB), 3M/ESPE] or a self-etching adhesive system [Clearfil S3 Bond (S3), Kuraray Co., Ltd.] to saliva-contaminated enamel, comparing two curing protocols: individual light curing of the adhesive system and the sealant or simultaneous curing of both materials. Mesial and distal enamel surfaces from 45 sound third molars were randomly assigned to 6 groups (n=15), according to the bonding technique: I - F was applied to 37% phosphoric acid etched enamel. The other groups were contaminated with fresh human saliva (0.01 mL; 10 s) after acid etching: II - SB and F were light cured separately; III - SB and F were light cured together; IV - S3 and F were light cured separately; V - S3 and F were light cured simultaneously; VI - F was applied to saliva-contaminated, acid-etched enamel without an intermediate bonding agent layer. SBS was tested to failure in a universal testing machine at 0.5 mm/min. Data were analyzed by one-way ANOVA and Fisher's test (alpha=0.05).The debonded specimens were examined with a stereomicroscope to assess the failure modes. Three representative specimens from each group were observed under scanning electron microscopy for a qualitative analysis. Mean SBS in MPa were: I-12.28 (+/-4.29); II-8.57 (+/-3.19); III-7.97 (+/-2.16); IV-12.56 (+/-3.11); V-11.45 (+/-3.77); and VI-7.47 (+/-1.99). In conclusion, individual or simultaneous curing of the intermediate bonding agent layer and the resin sealant did not seem to affect bond strength to saliva-contaminated enamel. S3/F presented significantly higher SBS than the that of the groups treated with SB etch-and-rinse adhesive system and similar SBS to that of the control group, in which the sealant was applied under ideal dry, noncontaminated conditions.

  3. Bone induction by composites of bioresorbable carriers and demineralized bone in rats: a comparative study of fibrin-collagen paste, fibrin sealant, and polyorthoester with gentamicin

    DEFF Research Database (Denmark)

    Pinholt, E M; Solheim, E; Bang, G

    1992-01-01

    fibrin-collagen paste and fibrin sealant inhibited bone induction and produced a chronic inflammation; part of the fibrin-collagen paste was still present at 4 weeks. Polyorthoester with gentamicin was almost completely absorbed, induced minimal tissue reaction, and did not inhibit osteoinduction....

  4. Fissure sealants: in vitro evaluation of abrasion wear and superficial roughness

    Directory of Open Access Journals (Sweden)

    Vanessa Pardi

    2008-06-01

    Full Text Available The aim of this study was to compare the in vitro wear and superficial roughness of four materials (Delton Dyract Flow, Dentsply; Filtek Flow, Vitremer, 3M ESPE used as fissure sealant in 32 extracted human molars divided in four groups (n = 8 after abrasion with toothbrush/dentifrice. Impressions of each occlusal surface were made to analyze wear and circular specimens were prepared to analyze the roughness. Teeth and specimens were mounted in a toothbrushing machine. The replicas were observed using a SEM to determine the superficial wear. Wear: there were no statistically significant differences either between Delton and Filtek Flow or between Dyract Flow and Vitremer. Roughness: there were no statistical differences between Filtek Flow and Dyract Flow, Dyract Flow and Vitremer, Vitremer and Delton., Considering the clinical practice, if caries activity is present the use of Vitremer is suggested not only for its well known fluoride release, but it presented good roughness results.

  5. Implications for high-precision dose radiation therapy planning or limited surgical resection after percutaneous computed tomography-guided lung nodule biopsy using a tract sealant

    Directory of Open Access Journals (Sweden)

    Patricia M. de Groot, MD

    2018-04-01

    Full Text Available Purpose: Precision radiation therapy such as stereotactic body radiation therapy and limited resection are being used more frequently to treat intrathoracic malignancies. Effective local control requires precise radiation target delineation or complete resection. Lung biopsy tracts (LBT on computed tomography (CT scans after the use of tract sealants can mimic malignant tract seeding (MTS and it is unclear whether these LBTs should be included in the calculated tumor volume or resected. This study evaluates the incidence, appearance, evolution, and malignant seeding of LBTs. Methods and materials: A total of 406 lung biopsies were performed in oncology patients using a tract sealant over 19 months. Of these patients, 326 had follow-up CT scans and were included in the study group. Four thoracic radiologists retrospectively analyzed the imaging, and a pathologist examined 10 resected LBTs. Results: A total of 234 of 326 biopsies (72%, including primary lung cancer [n = 98]; metastases [n = 81]; benign [n = 50]; and nondiagnostic [n = 5] showed an LBT on CT. LBTs were identified on imaging 0 to 3 months after biopsy. LBTs were typically straight or serpiginous with a thickness of 2 to 5 mm. Most LBTs were unchanged (92% or decreased (6.3% over time. An increase in LBT thickness/nodularity that was suspicious for MTS occurred in 4 of 234 biopsies (1.7%. MTS only occurred after biopsy of metastases from extrathoracic malignancies, and none occurred in patients with lung cancer. Conclusions: LBTs are common on CT after lung biopsy using a tract sealant. MTS is uncommon and only occurred in patients with extrathoracic malignancies. No MTS was found in patients with primary lung cancer. Accordingly, potential alteration in planned therapy should be considered only in patients with LBTs and extrathoracic malignancies being considered for stereotactic body radiation therapy or wedge resection.

  6. Use of FloSeal Sealant in the Surgical Management of Tubal Ectopic Pregnancy

    Directory of Open Access Journals (Sweden)

    Mara Clapp

    2013-01-01

    Full Text Available Background. Surgery is sometimes required for the management of tubal ectopic pregnancies. Historically, surgeons used electrosurgery to obtain hemostasis. Topical hemostatic sealants, such as FloSeal, may decrease the reliance on electrosurgery and reduce thermal injury to the tissue. Case. A 33-year-old G1 P0 received methotrexate for a right tubal pregnancy. The patient became symptomatic six days later and underwent a laparoscopic right salpingotomy. After multiple unsuccessful attempts to obtain hemostasis with electrocoagulation, FloSeal was used and hemostasis was obtained. Six weeks later, a hysterosalpingogram (HSG confirmed tubal patency. The patient subsequently had an intrauterine pregnancy. Conclusion. FloSeal helped to achieve hemostasis during a laparoscopic salpingotomy and preserve tubal patency. FloSeal is an effective alternative and adjunct to electrosurgery in the surgical management of tubal pregnancy.

  7. The effect of biological sealants and adhesive treatments on matrix metalloproteinase expression during renal injury healing.

    Directory of Open Access Journals (Sweden)

    José Miguel Lloris-Carsí

    Full Text Available Renal injuries are relatively common in cases of abdominal trauma. Adhesives and sealants can be used to repair and preserve damaged organs. Using a rat model, this study explores the activity of different matrix metalloproteinases (MMP during the healing of renal injuries treated by two biological adhesives (TachoSil and GelitaSpon and a new synthetic elastic cyanoacrylate (Adhflex.Renal traumatic injuries were experimentally induced in 90 male Wistar rats by a Stiefel Biopsy Punch in the anterior aspect of the left kidney. Animals were divided into five groups: 1, sham non-injured (n = 3; 2, non-treated standard punch injury (n = 6; 3, punch injury treated with TachoSil (n = 27; 4, punch injury treated with GelitaSpon (n = 27; and, 5, punch injury treated with Adhflex (n = 27. Wound healing was evaluated 2, 6, and 18 days after injury by determining the expression of MMPs, and the histopathological evolution of lesions.Histologically, the wound size at 6 days post-injury was larger in Adhflex-treated samples than in the other treatments, but the scarring tissue was similar at 18 days post-injury. Only the MMPs subtypes 1, 2, 8, 9, and 13 were sufficiently expressed to be quantifiable. Both time since injury and treatment type had a significant influence on MMPs expression. Two days after injury, the expression of MMP8 and MMP9 was predominant. MMP2 expression was greater 6 days after injury. The Adhflex-treated group had a significantly higher MMPs expression than the other treatment groups at all healing stages.All three sealant treatments induced almost similar expression of MMPs than untreated animals indicating a physiological healing process. Given that all renal trauma injuries must be considered emergencies, both biological and synthetic adhesives, such as Adhflex, should be considered as a treatment options.

  8. Stability of Beriplast P fibrin sealant: storage and reconstitution.

    Science.gov (United States)

    Eberhard, Ulrich; Broder, Martin; Witzke, Günther

    2006-04-26

    This study was performed to investigate the stability of Beriplast P fibrin sealant (FS) across a range of storage conditions, both pre- and post-reconstitution. Storage stability of the FS was evaluated during long-term refrigeration (24 months) with or without interim storage at elevated temperatures (40 degrees C for 1 week and 25 degrees C for 1 and 3 months). Stability of individual FS components was assessed by measuring: fibrinogen content, Factor XIII activity (FXIII), thrombin activity and aprotinin potency. The package integrity of each component was also checked (sterility testing, moisture content and pH). Storage stability was also evaluated by testing the reconstituted product for adhesion (tearing force testing after mixing the solutions) and sterility. Reconstitution stability was evaluated following 3-months' storage, for up to 50 h post-reconstitution using the same tests as for the storage stability investigations. Pre-defined specifications were met for fibrinogen content, Factor XIII activity, and thrombin activity, demonstrating storage stability. Package integrity and the functionality and sterility of the reconstituted product were confirmed throughout. Reconstitution stability was demonstrated for up to 50 h following reconstitution, in terms of both tearing force and sterility tests. In conclusion, the storage stability of Beriplast P was demonstrated over a range of 24-month storage schedules including interim exposure to elevated temperature, and the reconstituted product was stable for up to 50 h.

  9. Effectiveness of audiovisual distraction in behavior modification during dental caries assessment and sealant placement in children with autism spectrum disorder.

    Science.gov (United States)

    Fakhruddin, Kausar Sadia; El Batawi, Hisham Yehia

    2017-01-01

    The aim of this study was to evaluate the effectiveness of audiovisual (AV) distraction in behavior modification during dental caries assessment and sealant placement in children with autism spectrum disorder. This study was conducted on 28 children diagnosed with autism spectrum disorder, aged 6.5-9.8 years. Children underwent one introductory (desensitization) appointment and three treatment sessions. During the introductory session, children had the procedures explained to them, they watched a movie projected on a screen while oral screening and assessment of cooperation level were carried out. In treatment session I, oral examination, charting, and dental x-rays were undertaken, whereas the children watched movies with or without video eyewear. During treatment sessions II/III, dental prophylaxis was carried out on upper and lower jaws in addition to the application of dental sealants on the right upper and lower and the left upper and lower permanent molars, respectively, while the children were distracted by cartoon movies using video eyewear. Changes in pulse oximeter and heart rate were recorded every 5 min. Independent samples t -test was used to assess the significance of changes in pulse and O 2 saturation levels during each visit. International Caries Detection and Assessment System-code 2 was found to be the most prevalent ( n = 58; 52%). A significant difference ( P behavior in the subjects. Video eyewear distraction proved an effective tool in managing children with autism spectrum disorder during noninvasive preventive dental procedures.

  10. Laparoendoscopic single-site myomectomy and the use of fibrin sealant (Tisseel

    Directory of Open Access Journals (Sweden)

    Angelito Magno

    2015-11-01

    ensured after the suturing. A fibrin sealant, Tisseel (Baxter Healthcare Corp., Deerfield, IL, is applied over the suture site as an adjunct to hemostasis and also to prevent adhesion. The fundamental advantage of LESS is less incision, as a result, improves cosmesis. LESS myomectomy has many technical difficulties, including reduced visualization, loss of triangulation, and instrument interference. Thus, the type, location and numbers of the myomas are critical to succeed LESS myomectomy. The Food and Drug Administration has approved fibrin sealant in 1998 as an adjunct to hemostasis and sealing. Besides, certain studies have reported its anti-adhesion property. Upon mixing of the two components in the lumens of Tisseel, the combinations of thrombin and fibrinogen transformed into fibrin, forming a rubber-like tissue that adheres to the wound surface.

  11. Acid neutralizing, mechanical and physical properties of pit and fissure sealants containing melt-derived 45S5 bioactive glass.

    Science.gov (United States)

    Yang, Song-Yi; Piao, Yin-Zhu; Kim, Sung-Min; Lee, Yong-Keun; Kim, Kyoung-Nam; Kim, Kwang-Mahn

    2013-12-01

    The aim of this study was to examine the effects of 45S5 bioactive glass (BAG) on the acid neutralizing, mechanical and physical properties of pit and fissure sealants. 45S5BAG (glass (180 ± 30 nm) and added into a resin matrix [Bis-GMA/TEGDMA 50/50 (wt%) containing 1% of DMAEMA/CQ 2:1 (wt%)] with varying filler proportions; 0% 45S5BAG+50% glass (BAG0); 12.5% 45S5BAG+37.5% glass (BAG12.5); 25% 45S5BAG+25% glass (BAG25); 37.5% 45S5BAG+12.5% glass (BAG37.5); and 50% 45S5BAG+0% glass (BAG50). To evaluate the acid neutralizing properties, specimens were immersed in lactic acid solution (pH 4.0). Then, the change in pH and the time required to raise the pH from 4.0 to 5.5 were measured. In addition, flexural strength, water sorption and solubility were analyzed. The acid neutralizing properties of each group exhibited increasing pH values as more 45S5BAG was added, and the time required to raise the pH from 4.0 to 5.5 became shorter as the proportion of 45S5BAG increased (P0.05), except for BAG50. The novel pit and fissure sealants neutralized the acid solution (pH 4.0) and exhibited appropriate mechanical and physical properties. Therefore, these compounds are suitable candidates for caries-inhibiting dental materials. Copyright © 2013 Academy of Dental Materials. Published by Elsevier Ltd. All rights reserved.

  12. Wear and superficial roughness of glass ionomer cements used as sealants, after simulated toothbrushing Desgaste e rugosidade superficial de cimentos de ionômero de vidro utilizados como selantes, após escovação simulada

    Directory of Open Access Journals (Sweden)

    Daniela Rios

    2002-12-01

    Full Text Available The purpose of this study was to evaluate, in vitro, the properties (wear and roughness of glass ionomer cements that could influence their indication as pit and fissure sealants. The utilized materials were Fuji Plus, Ketac-Molar and Vitremer (in two different proportions: 1:1 and ¼:1. The resin-based sealant Delton was used as control. By means of an electronic balance (precision of 10-4 g, wear was measured in function of weight loss after simulated toothbrushing. Superficial roughness was determined by means of a surface roughness-measuring apparatus. The results revealed that diluted Vitremer and Fuji Plus were less resistant to toothbrushing abrasion and had the greatest increase in superficial roughness.Although in clinical situations luting or diluted ionomer cements are often utilized as alternatives to resin-based sealants, the resultsof this study revealed that the properties of those cements are worse than those of restorative ionomers, whichpresented results similar to those of the evaluated resin sealant.O presente estudo foi conduzido in vitro com o intuito de constatar as propriedades (desgaste e rugosidade dos CIV, as quais influenciam na sua indicação como material selador de fossas e fissuras. Os materiais empregados foram Fuji Plus, Ketac-Molar e Vitremer (duas proporções: 1:1 e ¼:1. O selante Delton foi controle. A determinação do desgaste foi obtida através da quantidade de massa perdida após a escovação e a rugosidade através da análise quantitativa da superfície. Os resultados mostraram que o Vitremer diluído e o Fuji Plus apresentaram maior grau de desgaste e maior aumento de rugosidade. Apesar de clinicamente se encontrar um maior uso dos ionômeros de vidro cimentantes ou diluídos como forma alternativa para material selador; este trabalho permitiu concluir que estes possuem propriedades bastante inferiores quando comparados aos ionômeros restauradores que, por sua vez, possuem resultados semelhantes

  13. Retention and penetration of a conventional resin-based sealant and a photochromatic flowable composite resin placed on occlusal pits and fissures

    Directory of Open Access Journals (Sweden)

    Aguilar F

    2007-01-01

    Full Text Available This study compares the retention and penetration of a conventional resin-based sealant (Fluroshield and a photochromatic flowable composite resin (Tetric Flow Chroma placed on occlusal pits and fissures and submitted to thermal or chemical cycling regimens. Penetration assessment - ten premolars were sealed with each material, isolated (except for the sealed surface and immersed in 0.2% Rhodamine B. The teeth were serially sectioned in a mesiodistal direction. The images of the sections were digitized and analyzed (ImageLab. The distance between the most superficial and the deepest points on the occlusal central groove was calculated to determine the groove′s total depth. The length of the central groove filled with the sealant was divided by its total depth to obtain the percentage of sealing of the occlusal groove. Retention assessment - 30 premolars were sealed, their occlusal surfaces were photographed and the area occupied by the sealing materials was demarcated (ImageLab. The teeth were submitted to different treatments: thermocycled, stored in artificial saliva and immersed in acetic acid and saliva (10 cycles/day protocol for 30 days. New photographs were taken to assess the final area occupied by the materials. The difference between the final and initial area was calculated to obtain the material loss. The data was analyzed (two-way anova and Tukey′s test P < 0.05. Both materials presented similar penetration of the occlusal central groove. After thermal and chemical cycling, the materials did not differ with respect to retention, except for immersion in acetic acid. In this case, Tetric Flow Chroma presented greater retention than Fluoroshield.

  14. Measurement of properties of sealant materials for solid oxide fuel cell systems

    International Nuclear Information System (INIS)

    Boersma, R.J.; Sammes, N.M.; Zhang, Y.

    1998-01-01

    Thermal expansion of ceramic materials, ceramic cements and steels was studied, and their compatibility with materials used in the SOFC system was evaluated. A number of ceramic cements, a glass paste and a glass ceramic were examined to identify their potential as a sealing material in a tubular fuel cell system. Thermal expansion coefficients of these materials were compared for thermal matching with materials employed in the fuel cell construction, such as yttria stabilised with 8 mole% zirconia (8YSZ) and stainless steel. A reasonable match was found for Macor, a glass ceramic, with one of the steel samples studied and with 8YSZ. Candidate sealants were tested for bonding quality, which made it evident that the ceramic cements had to be discarded. Good bonds between Macor and one of the steel samples and Macor and 8YSZ were formed, resulting in a gas tight seal. Uncertainty remains regarding the long term effect of the interface reactions between steel and Macor. Exposure of the Macor and a steel-Macor-8YSZ assembly to the different fuel cell gas atmospheres revealed that the Macor reacts with hydrogen, the long term effect of which is also unknown. Copyright (1998) Australasian Ceramic Society

  15. Comparison of six different methods of cleaning and preparing occlusal fissure surface before placement of pit and fissure sealant: An in vitro study

    Directory of Open Access Journals (Sweden)

    A Agrawal

    2012-01-01

    Full Text Available Aim & Objectives : The purpose of this in vitro study was to evaluate and compare the microleakage of pit and fissure sealants after using six different preparation techniques: (a brush, (b pumice slurry application, (c bur, (d air polishing, (e air abrasion, and (f longer etching time. Material & Method : The study was conducted on 60 caries-free first premolars extracted for orthodontic purpose. These teeth were randomly assigned to six groups of 10 teeth each. Teeth were prepared using one of six occlusal surface treatments prior to placement of Clinpro" 3M ESPE light-cured sealant. The teeth were thermocycled for 500 cycles and stored in 0.9% normal saline. Teeth were sealed apically and coated with nail varnish 1 mm from the margin and stained in 1% methylene blue for 24 hours. Each tooth was divided buccolingually parallel to the long axis of the tooth, yielding two sections per tooth for analysis. The surfaces were scored from 0 to 2 for the extent of microleakage. Statistical Analysis : Results obtained for microleakage were analyzed by using t-tests at sectional level and chi-square test and analysis of variance (ANOVA at the group level. Results : The results of round bur group were significantly superior when compared to all other groups. The application of air polishing and air abrasion showed better results than pumice slurry, bristle brush, and longer etching time. Round bur group was the most successful cleaning and preparing technique. Air polishing and air abrasion produced significantly less microleakage than traditional pumice slurry, bristle brush, and longer etching time.

  16. Autologous but not Fibrin Sealant Patches for Stump Coverage Reduce Clinically Relevant Pancreatic Fistula in Distal Pancreatectomy: A Systematic Review and Meta-analysis.

    Science.gov (United States)

    Weniger, Maximilian; D'Haese, Jan Goesta; Crispin, Alexander; Angele, Martin Kurt; Werner, Jens; Hartwig, Werner

    2016-11-01

    Postoperative pancreatic fistula (POPF) causes significant morbidity and mortality after distal pancreatectomy. Patch coverage of the pancreatic stump is often used with the intention to prevent POPF. Despite numerous investigations, the effects of patch coverage remain unclear. The present meta-analysis aims to clarify the effects of patch coverage in distal pancreatectomy on the incidence of POPF. A systematic search of MEDLINE/PubMed and the Cochrane Database according to the PRISMA Statement was performed. Subsequently a meta-analysis on rates and overall incidence of POPF and length of hospital stay was carried out. By applying the inverse variance weighting method, the combined effect size and 95 % confidence interval were calculated. Heterogeneity was assessed using I 2 statistics. Five randomized controlled trials and six observational clinical studies were included for final analysis. A cumulative incidence of 43 % of POPF grades A-C was identified. Patch coverage in distal pancreatectomy is significantly associated with a decreased rate of POPF grade C (p = 0.006). Patches of autologous vascularized tissue significantly reduce the overall incidence of POPF (p = 0.04) and clinically relevant POPF grade B and C (p = 0.002). Fibrin sealant patches do not influence rates of POPF after distal pancreatectomy. None of the outcomes evaluated showed adverse results for the patch group. Patch coverage after distal pancreatectomy can reduce the rate of POPF. Patch coverage with autologous vascularized tissue but not fibrin sealant patches may be used to reduce clinically relevant POPF and postoperative morbidity in distal pancreatectomy.

  17. The efficiency and safety of fibrin sealant for reducing blood loss in primary total hip arthroplasty: A systematic review and meta-analysis.

    Science.gov (United States)

    Wang, Zhiyuan; Xiao, Lin; Guo, Hao; Zhao, Guanghui; Ma, Jianbing

    2017-01-01

    Total hip arthroplasty (THA) is associated with substantial blood loss. The objective of present systematic review and meta-analysis is to provide evidence from randomized controlled trials (RCTs) on the efficiency and safety of administration of fibrin sealant (FS) for reducing blood loss in patients undergoing primary THA. Potential relevant studies were identified from electronic databases including Medline, PubMed, Embase, ScienceDirect, web of science and Cochrane Library. Gray academic studies were also identified from the reference list of included studies. There was no language restriction. Pooling of data was carried out by using RevMan 5.1. Six randomized controlled trials (RCTs) met the inclusion criteria. Current meta-analysis indicated that there were significant differences in terms of total blood loss (MD = -153.77, 95% CI: -287.21 to -20.34, P = 0.02), postoperative hemoglobin level (MD = -0.25, 95% CI: -0.46 to -0.05, P = 0.02) and transfusion rate (RD = -0.12, 95% CI: -0.22 to -0.03, P = 0.01) between groups. No significant differences were found regarding the incidence of deep venous thrombosis (DVT) (RD = 0.00, 95% CI: -0.01to 0.01, P = 0.51) or other side effects. Administration of fibrin sealant in total hip arthroplasty may reduce total blood loss, postoperative hemoglobin decline and transfusion requirements. Moreover, no adverse effect was related to FS. Due to the limited quality of the evidence currently available, higher quality RCTs are required. Copyright © 2016 IJS Publishing Group Ltd. Published by Elsevier Ltd. All rights reserved.

  18. Prevention of lymphocele by using gelatin-thrombin matrix as a tissue sealant after pelvic lymphadenectomy in patients with gynecologic cancers: a prospective randomized controlled study.

    Science.gov (United States)

    Kim, Yun Hwan; Shin, Hyun Joo; Ju, Woong; Kim, Seung Cheol

    2017-05-01

    This prospective randomized controlled pilot study aimed to find whether gelatin-thrombin matrix used as a tissue sealant (FloSeal) can prevent the occurrence of pelvic lymphocele in patients with gynecologic cancer who has undergone pelvic lymphadenectomy. Each patient, who undergo a laparotomic pelvic lymph node dissection on both sides, was randomly assigned for FloSeal application on 1 side of the pelvis. The other side of the pelvis without any product application being the control side. The amount of lymph drainage at each side of the pelvis was measured for 3 days, and computed tomography scans were obtained 7 days and 6 months after surgery for detection of pelvic lymphocele. Among 37 cases, the median amount of lymph drainage was significantly decreased in the hemi-pelvis treated with FloSeal compared to the control hemi-pelvis (p=0.025). The occurrence of lymphocele was considerably reduced in treated hemi-pelvis (8/37, 21.6%) compared with control hemi-pelvis (12/37, 32.4%) after 7 post-operative days (p=0.219), and more decreased in the treated hemi-pelvis (5/37, 13.5%) compared with control hemi-pelvis (9/37, 24.3%) after postoperative 6 months (p=0.344). The application of FloSeal as a tissue sealant in lymph nodes resected tissues can reduce the incidence of pelvic lymphocele in gynecologic cancer patients. A large randomized controlled study could confirm these preliminary results. Copyright © 2017. Asian Society of Gynecologic Oncology, Korean Society of Gynecologic Oncology

  19. Performance of a polymer sealant coating in an arctic marine environment

    International Nuclear Information System (INIS)

    Moskowitz, P.; Cowgill, M.; Griffith, A.; Chernaenko, L.; Diashev, A.; Nazarian, A.

    2001-01-01

    The feasibility of using a polymer-based coating, Polibrid 705, to seal concrete and steel surfaces from permanent radioactive contamination in an Arctic marine environment has been successfully demonstrated using a combination of field and laboratory testing. A mobile, self-sufficient spraying device was developed to specifications provided by the Russian Northern Navy and deployed at the RTP Atomflot site, Murmansk, Russia. Demonstration coatings were applied to concrete surfaces exposed to conditions ranging from indoor pedestrian usage to heavy vehicle passage and container handling in a loading dock. A large steel container was also coated with the polymer, filled with solid radwaste, sealed, and left out of doors, exposed to the full annual Arctic weather cycle. The 12 months of field testing gave rise to little degradation of the sealant coating, except for a few chips and gouge marks on the loading bay surface that were readily repaired. Contamination resulting from radwaste handling was easily removed and the surface was not degraded by contact with the decontamination agents. The field tests were accompanied by a series of laboratory qualification tests carried out at a research laboratory in St. Petersburg. The laboratory tests examined a variety of properties, including bond strength between the coating and the substrate, thermal cycling resistance, wear resistance, flammability, and ease of decontamination. The Polibrid 705 coating met all the Russian Navy qualification requirements with the exception of flammability. In this last instance, it was decided to restrict application of the coating to land-based facilities

  20. Silver microparticles plus fibrin tissue sealant prevents incisional hernias in rats.

    Science.gov (United States)

    Primus, Frank E; Young, David M; Grenert, James P; Harris, Hobart W

    2018-07-01

    Open abdominal surgery is frequently complicated by the subsequent development of an incisional hernia. Consequently, more than 400,000 incisional hernia repairs are performed each year, adding over $15 billion per year to U.S. health-care expenditures. While the vast majority of studies have focused on improved surgical techniques or prosthetic materials, we examined the use of metallic silver microparticles to prevent incisional hernia formation through enhanced wound healing. A rodent incisional hernia model was used. Eighty-two rats were randomly placed into two control groups (saline alone and silver microparticles alone), and three experimental groups (0 mg/cm, 2.5 mg/cm, and 25 mg/cm of silver microparticles applied with a fibrin sealant). Incisional hernia incidence and size, tensile strength, and tissue histology were assessed after 28 days. A significant reduction of both incisional hernia incidence and hernia size was observed between the control groups and 2.5 mg/cm group, and between the control and 25 mg/cm group by nearly 60% and 90%, respectively (P < 0.05). Histological samples showed a noticeable increase in new fibrosis in the treated animals as compared with the controls, whereas the tensile strength between the groups did not differ. The novel approach of using silver microparticles to enhance wound healing appears to be a safe and effective method to prevent incisional hernias from developing and could herald a new era of medicinal silver use. Copyright © 2018 Elsevier Inc. All rights reserved.

  1. Investigation of Performance of SCN-1 Pure Glass as Sealant Used in SOFC

    Energy Technology Data Exchange (ETDEWEB)

    Liu, Wenning N.; Sun, Xin; Stephens, Elizabeth V.; Khaleel, Mohammad A.

    2010-03-01

    As its name implies, self-healing glass seal has the potential of restoring its mechanical properties upon being reheated to stack operating temperature, even when it has experienced some cooling induced damage/crack at room temperature. Such a self-healing feature is desirable for achieving high seal reliability during thermal cycling. On the other hand, self-healing glass is also characterized by its low mechanical stiffness and high creep rate at the typical operating temperature of SOFCs. Therefore, from a design’s perspective, it is important to know the long term geometric stability and thermal mechanical behaviors of the self-healing glass under the stack operating conditions. These predictive capabilities will guide the design and optimization of a reliable sealing system that potentially utilizes self-healing glass as well as other ceramic seal components in achieving the ultimate goal of SOFC. In this report, we focused on predicting the effects of various generic seal design parameters on the stresses in the seal. For this purpose, we take the test cell used in the leakage test for compliant glass seals conducted in PNNL as our initial modeling geometry. The effect of the ceramic stopper on the geometry stability of the self-healing glass sealants is studied first. Then we explored the effect of various interfaces such as stopper and glass, stopper and PEN, as well stopper and IC plate, on the geometry stability and reliability of glass during the operating and cooling processes.

  2. Surgical Treatment of Pressure Ulcers with a Fibrin Sealant in Patients with Spinal Cord Injury: A Cost-Consequence Analysis.

    Science.gov (United States)

    Velasco, Jose Manuel Arévalo; Lozano, Virginia; Oyagüez, Itziar; Casado, Miguel Angel

    2015-11-01

    A comparative study was performed to evaluate the effectiveness and costs of a fibrin sealant (Tissucol Duo [known as Tisseel in the United States], Baxter International, Deerfield, Illinois) to improve postoperative outcomes in patients with spinal cord injury undergoing surgical treatment for pressure ulcers (PrUs). Between January and June 2011, 27 patients underwent surgical treatment for PrUs with the direct application of Tissucol Duo sprayed before closure. The costs and outcomes obtained in this cohort were compared with those obtained in a previous retrospective study where 71 patients underwent conventional surgery. Lower rates of hematoma-seroma were observed in the study group (3.7% vs 33.8%; P costs. The application of Tissucol Duo during surgical treatment of PrUs in patients with spinal cord injury has been shown to be effective in reducing postoperative complications and in shortening the duration of the hospital stay with a consequent savings in costs.

  3. Evaluation of a fissure sealant program as part of community-based teaching and training.

    Science.gov (United States)

    van Wyk, Philippus J; Kroon, Jeroen; White, John G

    2004-01-01

    Since 1995 the Department of Community Dentistry of the University of Pretoria has been involved in the rendering of mobile primary oral health care services to children in the Hammanskraal area of Gauteng, South Africa, as part of their students' community-based training. Mokonyama Primary School was identified as the first school where a primary oral health care service could be rendered. The objective of this study was to evaluate the impact (outcomes) of a fissure sealant program on the dentition status of the school children. Seven years after the implementation of the program, the dentition status of children at Mokonyama was compared with that of a comparable group of children from the same area who were not exposed to the program. The results showed that the decayed, missing, and filled teeth in the primary dentition (dmft) in the six-year-old group in Mokonyama (1.74) did not differ significantly from the dmft (1.43) of the control group (p = 0.49). The decayed, missing, and filled teeth in the permanent dentition (DMFT) of 0.59 for the fifteen-year-old group in Mokonyama, however, differed significantly (p = 0.0001) from the DMFT of the control group (2.38). Fifteen-year-old children in Mokonyama had 75.2 percent fewer caries than their counterparts in the control group.

  4. Development and characterization of glass-ceramic sealants in the (CaO-Al2O3-SiO2-B2O3) system for Solid Oxide Electrolyzer Cells

    International Nuclear Information System (INIS)

    Khedim, Hichem; Nonnet, Helene; Mear, Francois O.

    2012-01-01

    The efficiency of glass-ceramic sealants plays a crucial role in Solid Oxide Electrolyzer Cell performance and durability. In order to develop suitable sealants, operating around 800 degrees C, two parent glass compositions, CAS1B and CAS2B, from the CaO-Al 2 O 3 -SiO 2 -B 2 O 3 system were prepared and explored. The thermal and physicochemical properties of the glass ceramics and their crystallization behavior were investigated by HSM. DTA and XRD analyses. The microstructure and chemical compositions of the crystalline phases were investigated by microprobe analysis. Bonding characteristic as well as chemical interactions of the parent glass with yttria-stabilized zirconia (YSZ) electrolyte and ferritic steel-based interconnect (Crofere (R)) were also investigated. The preliminary results revealed the superiority of CAS2B glass for sealing application in SOECs. The effect of minor additions of V 2 O 5 , K 2 O and TiO 2 on the thermal properties was also studied and again demonstrated the advantages of the CAS2B glass composition. Examining the influence of heat treatment on the seal behavior showed that the choice of the heating rate is a compromise between delaying the crystallization process and delaying the viscosity drop. The thermal Expansion Coefficients (TEC) obtained for the selected glass ceramic are within the desired range after the heat treatment of crystallization. The crystallization kinetic parameters of the selected glass composition were also determined under non-isothermal conditions by means of differential thermal analysis (DTA) and using the formal theory of transformations for heterogeneous nucleation. (authors)

  5. An observational cohort study on persistency of internal teat sealant residues in milk after calving in dairy cows.

    Science.gov (United States)

    Kabera, Fidèle; Dufour, Simon; Keefe, Greg; Roy, Jean-Philippe

    2018-04-04

    Our objectives were to evaluate the prevalence of quarters with an observable internal teat sealant (ITS) plug at first milking following calving and investigate persistency of ITS residues in milk after calving. An observational cohort study was carried out on 557 quarters of 156 cows treated with ITS in 6 farms in Quebec, Canada. The presence of an ITS plug at first milking and ITS residues in milk at each milking were observed by producers. The effects of various factors on the odds of observing an ITS plug and persistency of ITS residues in milk were studied using generalized logistic mixed and generalized negative binomial mixed models, respectively. Milk samples were taken on the day before dry-off and on 2 occasions after calving for bacterial identification to detect intramammary infection (IMI) using bacteriological culture followed by MALDI-TOF identification. The association between the absence of an ITS plug and the presence of new IMI was assessed using a mixed logistic regression model. Internal teat sealant plugs after calving were more often observed in rear quarters and in quarters receiving ITS alone at drying-off versus antimicrobial and ITS. We observed an average (standard deviation) persistency of 4.0 d (2.3 d). When an ITS plug was still present at first milking (83% of quarters), the elimination of ITS residues in milk after calving was significantly longer (4.5 d, on average) compared with 1.2 d when an ITS plug was absent. In cows with an ITS plug at calving, we observed a higher number of days of excretion in older cows. When a plug could not be observed, rear quarters, older cows, and cows with a long dry period duration excreted ITS residues for a significantly longer period. The lack of a significant association between the absence of a plug and the odds of new IMI at calving suggests that despite the loss of the plug, cows were still protected against new IMI. Although we were able to highlight some statistically significant risk

  6. Wound healing and degradation of the fibrin sealant Beriplast P following partial liver resection in rabbits.

    Science.gov (United States)

    Kroez, Monika; Lang, Wiegand; Dickneite, Gerhard

    2005-01-01

    The objective of this study was to investigate the degradation kinetics of the fibrin sealant (FS) Beriplast P in an experimental liver surgery model in rabbits. A partial liver resection was performed in 21 rabbits, and the wound area covered with Beriplast P to ensure hemostasis. Wound healing of the resection sites was evaluated morphologically over 11 weeks. Degradation of the FS was evaluated by measuring the thickness of the remaining fibrin layer. Plasma samples were analyzed for antibodies against fibrinogen, albumin, thrombin, fibrin, and factor XIII. No postoperative hemorrhage was observed, indicating successful hemostasis throughout. The FS was degraded with a half-life of about 25 days postapplication and was completely replaced by granulation tissue within 9 weeks. The FS degradation and tissue development followed the general stages of wound healing: inflammation and resorption, proliferation, organization and production of collagen, maturation, and scarring. An immune reaction was elicited against the main four human proteins of the FS. The antibody titers peaked on day 14, with a gradual decrease thereafter. We conclude that the FS accomplished hemostasis, facilitated healing in accordance with natural processes, and was completely degraded over time. In humans, the reduced immunogenicity of the FS would potentially increase its degradation half-life.

  7. Final environmental and regulatory assessment of using asphalt as a sealant in mine shafts

    International Nuclear Information System (INIS)

    1987-01-01

    This report discusses the properties of asphalt, the current regulatory status governing asphalt and future regulatory implications which may be pertinent in using asphalt as a waterproof shaft sealant. An understanding of the inherent organic composition of asphalt, an increase in the number of health and environmental research publications conducted on asphalt and an examination of the apparent trend of regulatory agencies toward more stringent environmental regulation governing the use of organic materials suggests asphalt could become regulated at a future time. This would only occur, however, if asphalt was found to conform to the present regulatory definitions of pollutants, contaminants or hazardous substances or if asphalt was included on a regulated substance list. In this regard, the study points out that asphalt contains very low levels of hazardous poly-nuclear aromatics (PNA's). These levels are significantly lower than the levels present in coal tars, a substance known to contain high levels of hazardous PNA's. Asphalt, however, has the inherent potential of producing higher concentrations of PNA's if the adverse condition of cracking should occur during the refinery production stage or on-site preparation of the asphalt. Also, unless existing control technology is applied, emission levels of sulfur dioxide, carbon monoxide, particulates and volatile organic carbons from the on-site preparation facilities could approach the permissible health standard levels of EPA. The study indicates, however, that available literature is limited on these issues

  8. Efficacy of a Self-expanding Tract Sealant Device in the Reduction of Pneumothorax and Chest Tube Placement Rates After Percutaneous Lung Biopsy: A Matched Controlled Study Using Propensity Score Analysis.

    Science.gov (United States)

    Ahrar, Judy U; Gupta, Sanjay; Ensor, Joe E; Mahvash, Armeen; Sabir, Sharjeel H; Steele, Joseph R; McRae, Stephen E; Avritscher, Rony; Huang, Steven Y; Odisio, Bruno C; Murthy, Ravi; Ahrar, Kamran; Wallace, Michael J; Tam, Alda L

    2017-02-01

    To evaluate the use of a self-expanding tract sealant device (BioSentry™) on the rates of pneumothorax and chest tube insertion after percutaneous lung biopsy. In this retrospective study, we compared 318 patients who received BioSentry™ during percutaneous lung biopsy (treated group) with 1956 patients who did not (control group). Patient-, lesion-, and procedure-specific variables, and pneumothorax and chest tube insertion rates were recorded. To adjust for potential selection bias, patients in the treated group were matched 1:1 to patients in the control group using propensity score matching based on the above-mentioned variables. Patients were considered a match if the absolute difference in their propensity scores was ≤equal to 0.02. Before matching, the pneumothorax and chest tube rates were 24.5 and 13.1% in the control group, and 21.1 and 8.5% in the treated group, respectively. Using propensity scores, a match was found for 317 patients in the treatment group. Chi-square contingency matched pair analysis showed the treated group had significantly lower pneumothorax (20.8 vs. 32.8%; p = 0.001) and chest tube (8.2 vs. 20.8%; p 30 cases of both treatment and control cases demonstrated similar findings: the treated group had significantly lower pneumothorax (17.6 vs. 30.2%; p = 0.002) and chest tube (7.2 vs. 18%; p = 0.001) rates. The self-expanding tract sealant device significantly reduced the pneumothorax rate, and more importantly, the chest tube placement rate after percutaneous lung biopsy.

  9. Comparison of cephalonium alone and in combination with an internal teat sealant for dry cow therapy in seasonally calving dairy cows.

    Science.gov (United States)

    Bates, A J; Chambers, G; Laven, R A

    2016-03-01

    To assess the effect of combining an internal teat sealant (ITS) and a long-acting cephalonium-based dry cow therapy (DCT) on the prevalence of cows with a somatic cell count (SCC) >150,000 cells/mL 60-80 days after calving, and the incidence of clinical mastitis diagnosed by farm staff in the first 100 days after calving. Cows from a spring-calving, pasture-based, dairy farm in the South Canterbury region of New Zealand were randomly allocated to receive cephalonium DCT (n=289) or cephalonium and internal teat sealant (n=304) at the end of lactation. Cows were inspected twice daily by farm staff during the dry period and following calving for signs of mastitis. Individual SCC were determined from herd tests conducted in the previous lactation and following calving. Logistic regression models were used to determine relationships with the prevalence of cows with a SCC >150,000 cells/mL after calving, and survival analysis was used to model time to the first case of clinical mastitis following calving at the cow and quarter level. The OR for a cow with a SCC >150,000 cells/mL after calving, including age and individual SCC in the preceding lactation in the model, was 0.53 (95% CI=0.32-0.89) for cows treated with combination therapy compared to cows receiving cephalonium (p=0.017). At the cow level, including age and preceding SCC in the model, the hazard ratio for diagnosis of clinical mastitis by farm staff in the first 100 days of lactation was 0.60 (95% CI=0.39-0.98) for cows treated with combination therapy compared to cows receiving cephalonium (p=0.04). At the quarter level, the hazard ratio for diagnosis of clinical mastitis, with age included in the model, was 0.41 (95% CI=0.23-0.74) for the combination therapy compared to cephalonium alone (pmastitis diagnosed by farm staff in the 100 days after calving, and the prevalence of cows with a SCC >150,000 cells/mL 60-80 days after calving. This study adds to the evidence that the prevention of intra mammary

  10. Free volume of mixed cation borosilicate glass sealants elucidated by positron annihilation lifetime spectroscopy and its correlation with glass properties

    Science.gov (United States)

    Ojha, Prasanta K.; Rath, Sangram K.; Sharma, Sandeep K.; Sudarshan, Kathi; Pujari, Pradeep K.; Chongdar, Tapas K.; Gokhale, Nitin M.

    2015-01-01

    The role of La+3/Sr+2 ratios, which is varied from 0.08 to 5.09, on density, molar volume, packing fraction, free volume, thermal and electrical properties in strontium lanthanum aluminoborosilicate based glass sealants intended for solid oxide fuel cell (SOFC) applications is evaluated. The studies reveal expansion of the glass network evident from increasing molar volume and decreasing packing fraction of glasses with progressive La+3 substitutions. The molecular origin of these macroscopic structural features can be accounted for by the free volume parameters measured from positron annihilation lifetime spectroscopy (PALS). The La+3 induced expanded glass networks show increased number of subnanoscopic voids with larger sizes, as revealed from the ortho-positronium (o-Ps) lifetime and its intensity. A remarkably direct correspondence between the molar volume and fractional free volume trend is established with progressive La2O3 substitution in the glasses. The effect of these structural changes on the glass transition temperature, softening temperature, coefficient of thermal expansion, thermal stability as well as electrical conductivity has been studied.

  11. The Use of Pit and Fissure Sealants—A Literature Review

    Directory of Open Access Journals (Sweden)

    Reem Naaman

    2017-12-01

    Full Text Available This paper reviews the literature and discusses the latest updates on the use of pit and fissure sealants. It demonstrates the effectiveness of pit and fissure sealants in preventing caries and the management of early carious lesions. It compares the use of different sealant materials and their indications. It describes the application technique for sealants. It also reviews the cost-effectiveness of sealants as a preventive strategy. From this review and after the discussion of recently published studies on pit and fissure sealants, it is evident that sealants are effective in caries prevention and in preventing the progression of incipient lesions. It is therefore recommended that pit and fissure sealant be applied to high-caries-risk children for optimum cost-effectiveness. It is a highly sensitive technique that needs optimum isolation, cleaning of the tooth surface, etching, and the application of a thin bonding layer for maximum benefit. Recall and repair, when needed, are important to maximize the effectiveness of such sealant use.

  12. The Use of Pit and Fissure Sealants—A Literature Review

    Science.gov (United States)

    Naaman, Reem; El-Housseiny, Azza A.; Alamoudi, Najlaa

    2017-01-01

    This paper reviews the literature and discusses the latest updates on the use of pit and fissure sealants. It demonstrates the effectiveness of pit and fissure sealants in preventing caries and the management of early carious lesions. It compares the use of different sealant materials and their indications. It describes the application technique for sealants. It also reviews the cost-effectiveness of sealants as a preventive strategy. From this review and after the discussion of recently published studies on pit and fissure sealants, it is evident that sealants are effective in caries prevention and in preventing the progression of incipient lesions. It is therefore recommended that pit and fissure sealant be applied to high-caries-risk children for optimum cost-effectiveness. It is a highly sensitive technique that needs optimum isolation, cleaning of the tooth surface, etching, and the application of a thin bonding layer for maximum benefit. Recall and repair, when needed, are important to maximize the effectiveness of such sealant use. PMID:29563440

  13. Efficacy of a Self-expanding Tract Sealant Device in the Reduction of Pneumothorax and Chest Tube Placement Rates After Percutaneous Lung Biopsy: A Matched Controlled Study Using Propensity Score Analysis

    Energy Technology Data Exchange (ETDEWEB)

    Ahrar, Judy U., E-mail: judy.ahrar@mdanderson.org; Gupta, Sanjay [The University of Texas M.D. Anderson Cancer Center, Department of Interventional Radiology (United States); Ensor, Joe E. [Houston Methodist Research Institute, The Houston Methodist Cancer Center (United States); Mahvash, Armeen; Sabir, Sharjeel H.; Steele, Joseph R.; McRae, Stephen E.; Avritscher, Rony; Huang, Steven Y.; Odisio, Bruno C.; Murthy, Ravi; Ahrar, Kamran; Wallace, Michael J.; Tam, Alda L. [The University of Texas M.D. Anderson Cancer Center, Department of Interventional Radiology (United States)

    2017-02-15

    PurposeTo evaluate the use of a self-expanding tract sealant device (BioSentry™) on the rates of pneumothorax and chest tube insertion after percutaneous lung biopsy.Materials and MethodsIn this retrospective study, we compared 318 patients who received BioSentry™ during percutaneous lung biopsy (treated group) with 1956 patients who did not (control group). Patient-, lesion-, and procedure-specific variables, and pneumothorax and chest tube insertion rates were recorded. To adjust for potential selection bias, patients in the treated group were matched 1:1 to patients in the control group using propensity score matching based on the above-mentioned variables. Patients were considered a match if the absolute difference in their propensity scores was ≤equal to 0.02.ResultsBefore matching, the pneumothorax and chest tube rates were 24.5 and 13.1% in the control group, and 21.1 and 8.5% in the treated group, respectively. Using propensity scores, a match was found for 317 patients in the treatment group. Chi-square contingency matched pair analysis showed the treated group had significantly lower pneumothorax (20.8 vs. 32.8%; p = 0.001) and chest tube (8.2 vs. 20.8%; p < 0.0001) rates compared to the control group. Sub-analysis including only faculty who had >30 cases of both treatment and control cases demonstrated similar findings: the treated group had significantly lower pneumothorax (17.6 vs. 30.2%; p = 0.002) and chest tube (7.2 vs. 18%; p = 0.001) rates.ConclusionsThe self-expanding tract sealant device significantly reduced the pneumothorax rate, and more importantly, the chest tube placement rate after percutaneous lung biopsy.

  14. Coating of Dacron vascular grafts with an ionic polyurethane: a novel sealant with protein binding properties.

    Science.gov (United States)

    Phaneuf, M D; Dempsey, D J; Bide, M J; Quist, W C; LoGerfo, F W

    2001-03-01

    The purpose of this study was to develop a novel sealant that would seal prosthetic vascular graft interstices and be accessible for protein binding. Crimped knitted Dacron vascular grafts were cleaned (CNTRL) and hydrolyzed in boiling sodium hydroxide (HYD). These HYD grafts were sealed using an 11% solids solution of a polyether-based urethane with carboxylic acid groups (PEU-D) via a novel technique that employs both trans-wall and luminal perfusion. Carboxylic acid content, determined via methylene blue dye uptake, was 2.3- and 4.2-fold greater in PEU-D segments (1.0+/-0.27 nmol/mg) as compared to HYD and CNTRL segments, respectively. Water permeation through PEU-D graft (1.1+/-2 ml/cm2 min(-1)) was comparable to collagen-impregnated Dacron (9.8+/-10 ml/cm2 min(-1)). Non-specific 125I-albumin (125I-Alb) binding to PEU-D segments (18+/-3 ng/mg) was significantly lower than HYD and CNTRL segments. 125I-Alb linkage to PEU-D using the crosslinker EDC resulted in 5.7-fold greater binding (103+/-2 ng/mg) than non-specific PEU-D controls. However, covalent linkage of 125I-Alb to PEU-D was 4.9- and 5.9-fold less than CNTRL and HYD segments with EDC, respectively. Thus, ionic polyurethane can be applied to a pre-formed vascular graft, seal the interstices and create "anchor" sites for protein attachment.

  15. Synaptic plasticity and sensory-motor improvement following fibrin sealant dorsal root reimplantation and mononuclear cell therapy

    Science.gov (United States)

    Benitez, Suzana U.; Barbizan, Roberta; Spejo, Aline B.; Ferreira, Rui S.; Barraviera, Benedito; Góes, Alfredo M.; de Oliveira, Alexandre L. R.

    2014-01-01

    Root lesions may affect both dorsal and ventral roots. However, due to the possibility of generating further inflammation and neuropathic pain, surgical procedures do not prioritize the repair of the afferent component. The loss of such sensorial input directly disturbs the spinal circuits thus affecting the functionality of the injuried limb. The present study evaluated the motor and sensory improvement following dorsal root reimplantation with fibrin sealant (FS) plus bone marrow mononuclear cells (MC) after dorsal rhizotomy. MC were used to enhance the repair process. We also analyzed changes in the glial response and synaptic circuits within the spinal cord. Female Lewis rats (6–8 weeks old) were divided in three groups: rhizotomy (RZ group), rhizotomy repaired with FS (RZ+FS group) and rhizotomy repaired with FS and MC (RZ+FS+MC group). The behavioral tests electronic von-Frey and Walking track test were carried out. For immunohistochemistry we used markers to detect different synapse profiles as well as glial reaction. The behavioral results showed a significant decrease in sensory and motor function after lesion. The reimplantation decreased glial reaction and improved synaptic plasticity of afferent inputs. Cell therapy further enhanced the rewiring process. In addition, both reimplanted groups presented twice as much motor control compared to the non-treated group. In conclusion, the reimplantation with FS and MC is efficient and may be considered an approach to improve sensory-motor recovery following dorsal rhizotomy. PMID:25249946

  16. Effect of irradiation times on the polymerization depth of contemporary fissure sealants with different opacities

    Directory of Open Access Journals (Sweden)

    Boniek Castillo Dutra Borges

    2011-04-01

    Full Text Available The aim of this study was to evaluate the depth of curing of 10 contemporary blue light-activated dental flowable materials at several opacities, influenced by different irradiation times using FT-IR spectroscopy. Fifty-five specimens (n = 5 with a 5-mm diameter and 1-mm thickness of translucent (Opallis Flow T, yellowed (Master Flow A2; Opallis Flow A2; Natural Flow A2; Fluroshield Yellowed, and opaque materials (Master Flow OA2; Natural Flow O; Opallis Flow OA3.5; Opallis Flow OP; Fluroshield White were obtained at six curing times (10s, 20s, 30s, 40s, 50s, and 60s using a high-intensity LED (Coltolux, Coltène/Whaledent. The degree of conversion (DC (% was obtained using the Nexus 470 FTIR Spectrometer (Nicolet Instruments, USA. The FTIR-ATR spectra for uncured and cured samples were analyzed using a ZnSe crystal. The top and bottom surfaces of the cured specimens were analyzed to obtain the depth of curing. Two-way ANOVA was used to analyze the data. The highest curing depth was obtained by Natural Flow OA2, while the lowest was shown by Master Flow OA2. The shortest curing time generated similar depths of cure in comparison with the most extensive for Opallis Flow A2 and Fluroshield Yellowed. Therefore, depth of curing, influenced by the irradiation time, was dependent on the materials. Using the Natural Flow OA2 opaque sealant and the 10-s curing time for Opallis Flow A2 and Fluroshield Yellowed may represent alternative approaches to sealing tooth fissures.

  17. Stable glass-ceramic sealants for solid oxide fuel cells: Influence of Bi{sub 2}O{sub 3} doping

    Energy Technology Data Exchange (ETDEWEB)

    Goel, Ashutosh; Ferreira, Jose M.F. [Department of Ceramics and Glass Engineering, University of Aveiro, CICECO, 3810-193 Aveiro (Portugal); Pascual, Maria J. [Instituto de Ceramica y Vidrio (CSIC), Kelsen 5, Campus de Cantoblanco, 28049 Madrid (Spain)

    2010-07-15

    Diopside (CaMgSi{sub 2}O{sub 6}) based glass-ceramics in the system SrO-CaO-MgO-Al{sub 2}O{sub 3}-B{sub 2}O{sub 3}-La{sub 2}O{sub 3}-Bi{sub 2}O{sub 3}-SiO{sub 2} have been synthesized for sealing applications in solid oxide fuel cells (SOFC). The parent glass composition in the primary crystallization field of diopside has been doped with different amounts of Bi{sub 2}O{sub 3} (1, 3, 5 wt.%). The sintering behavior by hot-stage microscopy (HSM) reveals that all the investigated glass compositions exhibit a two-stage shrinkage behavior. The crystallization kinetics of the glasses has been studied by differential thermal analysis (DTA) while X-ray diffraction adjoined with Rietveld-R.I.R. analysis have been employed to quantify the amount of crystalline and amorphous phases in the glass-ceramics. Diopside and augite crystallized as the primary crystalline phases in all the glass-ceramics. The coefficient of thermal expansion (CTE) of the investigated glass-ceramics varied between (9.06-10.14) x 10{sup -6} K{sup -1} after heat treatment at SOFC operating temperature for a duration varying between 1 h and 200 h. Further, low electrical conductivity, good joining behavior and negligible reactivity with metallic interconnects (Crofer22 APU and Sanergy HT) in air indicate that the investigated glass-ceramics are suitable candidates for further experimentation as sealants in SOFC. (author)

  18. An essential primer for understanding the role of topical hemostats, surgical sealants, and adhesives for maintaining hemostasis.

    Science.gov (United States)

    Gabay, Michael; Boucher, Bradley A

    2013-09-01

    A wide variety of topical hemostats are approved as adjunctive therapies in the maintenance of hemostasis during surgical procedures in which conventional methods are insufficient or not practical. A multidisciplinary approach to the selection and application of these agents requires input from all members of the surgical team including surgeons, perioperative nurses, blood bank specialists, and pharmacists. However, pharmacist knowledge regarding topical hemostats may be limited based on lack of formal education within college of pharmacy curricula as well as their use being predominantly in the operating room setting. Furthermore, some of these agents might be procured through central supply rather than the hospital pharmacy. Topical hemostats include agents that act as a mechanical barrier to bleeding and provide a physical matrix for clotting, biologically active agents that catalyze coagulation, combination therapies, and synthetic sealants and adhesives. Although many of the topical hemostats were approved for use before the requirement for clinical trials, this review provides an overview of the available clinical evidence regarding the appropriate uses and safety considerations associated with these agents. Proper use of these agents is vital to achieving the best clinical outcomes. Specifically, knowledge of the contraindications and potential adverse events associated with topical hemostats can help prevent unwanted outcomes. Therefore, an understanding of the benefits and potential risks associated with these agents will allow hospital pharmacists to assist in the development and implementation of institutional policies regarding the safe and effective use of hemostatic agents commonly used in the surgical suite. © 2013 Pharmacotherapy Publications, Inc.

  19. 77 FR 59090 - Approval and Promulgation of Air Quality Implementation Plans; Pennsylvania; Adhesives and...

    Science.gov (United States)

    2012-09-26

    ... Promulgation of Air Quality Implementation Plans; Pennsylvania; Adhesives and Sealants Rule AGENCY... manufacture, sale, use, or application of adhesives, sealants, primers, and solvents. The SIP revision also... proposed rulemaking (NPR) which proposed approval of Pennsylvania's adhesives and sealants regulations in...

  20. 76 FR 53369 - Approval and Promulgation of Air Quality Implementation Plans; Pennsylvania; Adhesives and...

    Science.gov (United States)

    2011-08-26

    ... Promulgation of Air Quality Implementation Plans; Pennsylvania; Adhesives and Sealants Rule AGENCY... volatile organic compounds (VOC) from the manufacture, sale, use, or application of adhesives, sealants... the adhesive, sealant, primer, and solvent product categories regulated under section 129.77 and...

  1. Air Distribution Retrofit Strategies for Affordable Housing

    Energy Technology Data Exchange (ETDEWEB)

    Dentz, Jordan [National Renewable Energy Lab. (NREL), Golden, CO (United States); Conlin, Francis [National Renewable Energy Lab. (NREL), Golden, CO (United States); Holloway, Parker [National Renewable Energy Lab. (NREL), Golden, CO (United States); Podorson, David [National Renewable Energy Lab. (NREL), Golden, CO (United States); Varshney, Kapil [National Renewable Energy Lab. (NREL), Golden, CO (United States)

    2014-03-01

    In multifamily and attached buildings, traditional duct sealing methods are often impractical or costly and disruptive because of the difficulty in accessing leakage sites. In this project, two retrofit duct sealing techniques -- manually-applied sealants and injecting a spray sealant, were implemented in several low-rise multi-unit buildings. An analysis on the cost and performance of the two methods are presented. Each method was used in twenty housing units: approximately half of each group of units are single story and the remainder two-story. Results show that duct leakage to the outside was reduced by an average of 59% through the use of manual methods, and by 90% in the units where the injected spray sealant was used. It was found that 73% of the leakage reduction in homes that were treated with injected spray sealant was attributable to the manual sealing done at boots, returns and the air handler. The cost of manually-applying sealant ranged from $275 to $511 per unit and for the injected spray sealant the cost was $700 per unit. Modeling suggests a simple payback of 2.2 years for manual sealing and 4.7 years for the injected spray sealant system. Utility bills were collected for one year before and after the retrofits. Utility bill analysis shows 14% and 16% energy savings using injected spray sealant system and hand sealing procedure respectively in heating season whereas in cooling season, energy savings using injected spray sealant system and hand sealing were both 16%.

  2. Air Distribution Retrofit Strategies for Affordable Housing

    Energy Technology Data Exchange (ETDEWEB)

    Dentz, J. [Advanced Residential Integrated Energy Solutions (ARIES), New York, NY (United States); Conlin, F. [Advanced Residential Integrated Energy Solutions (ARIES), New York, NY (United States); Holloway, Parker [Advanced Residential Integrated Energy Solutions (ARIES), New York, NY (United States); Podorson, David [Advanced Residential Integrated Energy Solutions (ARIES), New York, NY (United States); Varshney, Kapil [Advanced Residential Integrated Energy Solutions (ARIES), New York, NY (United States)

    2014-03-01

    In multifamily and attached buildings, traditional duct sealing methods are often impractical or costly and disruptive because of the difficulty in accessing leakage sites. In this project, two retrofit duct sealing techniques, manually-applied sealants and injecting a spray sealant, were implemented in several low-rise multiunit buildings. An analysis on the cost and performance of the two methods are presented. Each method was used in twenty housing units: approximately half of each group of units are single story and the remainder are two story. Results show that duct leakage to the outside was reduced by an average of 59% through the use of manual methods, and by 90% in the units where the injected spray sealant was used. It was found that 73% of the leakage reduction in homes that were treated with injected spray sealant was attributable to the manual sealing done at boots, returns and the air handler. The cost of manually-applying sealant ranged from $275 to $511 per unit and for the injected spray sealant the cost was $700 per unit. Modeling suggests a simple payback of 2.2 years for manual sealing and 4.7 years for the injected spray sealant system. Utility bills were collected for one year before and after the retrofits. Utility bill analysis shows 14% and 16% energy savings using injected spray sealant system and hand sealing procedure respectively in heating season whereas in cooling season, energy savings using injected spray sealant system and hand sealing were both 16%.

  3. Natural Type II Collagen Hydrogel, Fibrin Sealant, and Adipose-Derived Stem Cells as a Promising Combination for Articular Cartilage Repair.

    Science.gov (United States)

    Lazarini, Mariana; Bordeaux-Rego, Pedro; Giardini-Rosa, Renata; Duarte, Adriana S S; Baratti, Mariana Ozello; Zorzi, Alessandro Rozim; de Miranda, João Batista; Lenz Cesar, Carlos; Luzo, Ângela; Olalla Saad, Sara Teresinha

    2017-10-01

    Objective Articular cartilage is an avascular tissue with limited ability of self-regeneration and the current clinical treatments have restricted capacity to restore damages induced by trauma or diseases. Therefore, new techniques are being tested for cartilage repair, using scaffolds and/or stem cells. Although type II collagen hydrogel, fibrin sealant, and adipose-derived stem cells (ASCs) represent suitable alternatives for cartilage formation, their combination has not yet been investigated in vivo for focal articular cartilage defects. We performed a simple experimental procedure using the combination of these 3 compounds on cartilage lesions of rabbit knees. Design The hydrogel was developed in house and was first tested in vitro for chondrogenic differentiation. Next, implants were performed in chondral defects with or without ASCs and the degree of regeneration was macroscopically and microscopically evaluated. Results Production of proteoglycans and the increased expression of collagen type II (COL2α1), aggrecan (ACAN), and sex-determining region Y-box 9 (SOX9) confirmed the chondrogenic character of ASCs in the hydrogel in vitro. Importantly, the addition of ASC induced a higher overall repair of the chondral lesions and a better cellular organization and collagen fiber alignment compared with the same treatment without ASCs. This regenerating tissue also presented the expression of cartilage glycosaminoglycan and type II collagen. Conclusions Our results indicate that the combination of the 3 compounds is effective for articular cartilage repair and may be of future clinical interest.

  4. Tubeless percutaneous nephrolithotomy with non-absorbable hemostatic sealant (Quikclot®) versus nephrostomy tube placement: a propensity score-matched analysis.

    Science.gov (United States)

    Koo, Kyo Chul; Park, Sang Un; Jang, Ho Sung; Hong, Chang-Hee

    2015-11-01

    The purpose of this study was to determine the efficacy and safety of tubeless percutaneous nephrolithotomy (PNL) using a non-absorbable hemostatic sealant (Quikclot(®)) as an adjunct compared to nephrostomy tube placement in patients exhibiting significant parenchymal bleeding following PNL. We identified 113 PNL cases performed between May 2011 and October 2014. For patients with insignificant parenchymal bleeding following stone removal, defined as a clear visualization of the surgical field at full irrigation of the nephroscope, tubeless PNL was performed. For patients with significant parenchymal bleeding, we introduced the tubeless Quikclot(®) technique as of September 2013 and have performed it ever since. Formerly, nephrostomy placement PNL was performed. In this study, 40 Quikclot(®) applied PNL cases were matched with an equal number of nephrostomy placement cases by propensity scoring based on body mass index, stone size, and Guy's stone score. The mean postoperative drop in hematocrit was comparative between the Quikclot(®) group and the nephrostomy group on both postoperative days 1 (p = 0.459) and 2 (p = 0.325). Quikclot(®) application was associated with lower VAS scores throughout the postoperative period, lower cumulative analgesic requirement (p = 0.025), and with shorter hospitalization (p = 0.002). Complication rates were comparable with no need for blood transfusions in any patients. Tubeless Quikclot(®) PNL was safe and provided effective hemostasis of significant parenchymal bleeding. By avoiding nephrostomy placement, we were able to reduce postoperative pain, analgesic requirements, and hospitalization. Application of Quikclot(®) may be considered prior to nephrostomy placement in patients with significant parenchymal bleeding.

  5. Testing of isolation barrier sealing surfaces

    Energy Technology Data Exchange (ETDEWEB)

    Graves, C.E.

    1994-12-15

    Isolation barrier doors are to be installed in the 105KE and 105KW basins as part of the 1994 unreviewed safety question (USQ) resolution plan to isolate the fuel storage basin from the fuel discharge chute. Included in this installation is the placement of new sealing surfaces for the barriers by affixing stainless steel plates to existing carbon steel angle bars with a specially formulated epoxy adhesive/sealant material. The sealant is a two-part component consisting of an epoxy resin (the condensation product of bisphenol A and epichlorohydrin) and a curing agent (a proprietary cycloaliphatic polyamine). The sealant is solvent free (complying with air pollution regulations) and capable of withstanding the surrounding radiation fields over an estimated 15-year service life. The epoxy sealant experiences negligible water damage partly because of its hydrophobic (water-repelling) nature. With bond tensile strengths measured at greater than 862 kPa (125 lbf/in{sup 2}), the epoxy sealant is judged acceptable for its intended application. The four-hour pot life of the epoxy sealant provides sufficient time to apply the epoxy, examine the epoxy bead for continuity, and position the stainless steel sealing plates.

  6. Testing of isolation barrier sealing surfaces

    International Nuclear Information System (INIS)

    Graves, C.E.

    1994-01-01

    Isolation barrier doors are to be installed in the 105KE and 105KW basins as part of the 1994 unreviewed safety question (USQ) resolution plan to isolate the fuel storage basin from the fuel discharge chute. Included in this installation is the placement of new sealing surfaces for the barriers by affixing stainless steel plates to existing carbon steel angle bars with a specially formulated epoxy adhesive/sealant material. The sealant is a two-part component consisting of an epoxy resin (the condensation product of bisphenol A and epichlorohydrin) and a curing agent (a proprietary cycloaliphatic polyamine). The sealant is solvent free (complying with air pollution regulations) and capable of withstanding the surrounding radiation fields over an estimated 15-year service life. The epoxy sealant experiences negligible water damage partly because of its hydrophobic (water-repelling) nature. With bond tensile strengths measured at greater than 862 kPa (125 lbf/in 2 ), the epoxy sealant is judged acceptable for its intended application. The four-hour pot life of the epoxy sealant provides sufficient time to apply the epoxy, examine the epoxy bead for continuity, and position the stainless steel sealing plates

  7. SOLID RADIOACTIVE WASTE STORAGE TECHNOLOGIES: PERFORMANCE OF A POLYMER SEALANT COATING IN AN ARCTIC MARINE ENVIRONMENT

    International Nuclear Information System (INIS)

    COWGILL, M.G.; MOSKOWITZ, P.D.; CHERNAENKO, L.M.; NAZARIAN, A.; GRIFFITH, A.; DIASHEV, A.; ENGOY, T.

    2000-01-01

    This first project, under the auspices of the Arctic Military Environmental Cooperation (AMEC) forum, Project 1.4-1 Solid Radioactive Waste Storage Technologies, successfully demonstrated the feasibility of using a polymer-based coating to seal concrete and steel surfaces from permanent radioactive contamination in an Arctic marine environment. A mobile, self-sufficient spraying device, was developed to specifications provided by the Russian Ministry of Defence Northern Navy and was deployed at the RTP Atomflot site, Murmansk, Russia. Demonstration coatings of Polibrid 705 were applied to concrete surfaces exposed to conditions ranging from indoor pedestrian usage to heavy vehicle passage and container handling in a loading bay. A large steel container was also coated with the polymer, filled with solid radwaste, sealed, and left out of doors and exposed to the full 12 month Arctic weather cycle. The field tests were accompanied by a series of laboratory qualification tests carried out at the research laboratory of ICC Nuclide in St. Petersburg. During the 12-month field tests, the sealant coating showed little sign of degradation except for a few chips and gouge marks on the loading bay surface that were readily repaired. Contamination resulting from radwaste handling was easily removed and the surface was not degraded by contact with the decontamination agents. In the laboratory testing, Polibrid 705 met all the Russian qualification requirements with the exception of flammability. In this last instance, it was decided to restrict application of the coating to land-based facilities. The Russian technical experts from the Ministry of Defence quickly familiarized themselves with the equipment and were able to identify several areas of potential improvement as deployment of the equipment progressed. The prime among these was the desirability of extending the range of the equipment through enlarged gasoline tanks (to permit extended operational times) and longer

  8. Inhalation exposure during spray application and subsequent sanding of a wood sealant containing zinc oxide nanoparticles.

    Science.gov (United States)

    Cooper, Michael R; West, Gavin H; Burrelli, Leonard G; Dresser, Daniel; Griffin, Kelsey N; Segrave, Alan M; Perrenoud, Jon; Lippy, Bruce E

    2017-07-01

    Nano-enabled construction products have entered into commerce. There are concerns about the safety of manufactured nanomaterials, and exposure assessments are needed for a more complete understanding of risk. This study assessed potential inhalation exposure to ZnO nanoparticles during spray application and power sanding of a commercially available wood sealant and evaluated the effectiveness of local exhaust ventilation in reducing exposure. A tradesperson performed the spraying and sanding inside an environmentally-controlled chamber. Dust control methods during sanding were compared. Filter-based sampling, electron microscopy, and real-time particle counters provided measures of exposure. Airborne nanoparticles above background levels were detected by particle counters for all exposure scenarios. Nanoparticle number concentrations and particle size distributions were similar for sanding of treated versus untreated wood. Very few unbound nanoparticles were detected in aerosol samples via electron microscopy, rather nano-sized ZnO was contained within, or on the surface of larger airborne particles. Whether the presence of nanoscale ZnO in these aerosols affects toxicity merits further investigation. Mass-based exposure measurements were below the NIOSH Recommended Exposure Limit for Zn, although there are no established exposure limits for nanoscale ZnO. Local exhaust ventilation was effective, reducing airborne nanoparticle number concentrations by up to 92% and reducing personal exposure to total dust by at least 80% in terms of mass. Given the discrepancies between the particle count data and electron microscopy observations, the chemical identity of the airborne nanoparticles detected by the particle counters remains uncertain. Prior studies attributed the main source of nanoparticle emissions during sanding to copper nanoparticles generated from electric sander motors. Potentially contrary results are presented suggesting the sander motor may not have been

  9. Effect of platelet rich plasma and fibrin sealant on facial nerve regeneration in a rat model.

    Science.gov (United States)

    Farrag, Tarik Y; Lehar, Mohamed; Verhaegen, Pauline; Carson, Kathryn A; Byrne, Patrick J

    2007-01-01

    To investigate the effects of platelet rich plasma (PRP) and fibrin sealant (FS) on facial nerve regeneration. Prospective, randomized, and controlled animal study. Experiments involved the transection and repair of facial nerve of 49 male adult rats. Seven groups were created dependant on the method of repair: suture; PRP (with/without suture); platelet poor plasma (PPP) (with/without suture); and FS (with/without suture) groups. Each method of repair was applied immediately after the nerve transection. The outcomes measured were: 1) observation of gross recovery of vibrissae movements within 8-week period after nerve transection and repair using a 5-point scale and comparing the left (test) side with the right (control) side; 2) comparisons of facial nerve motor action potentials (MAP) recorded before and 8 weeks after nerve transection and repair, including both the transected and control (untreated) nerves; 3) histologic evaluation of axons counts and the area of the axons. Vibrissae movement observation: the inclusion of suturing resulted in overall improved outcomes. This was found for comparisons of the suture group with PRP group; PRP with/without suture groups; and PPP with/without suture groups (P .05). The movement recovery of the suture group was significantly better than the FS group (P = .014). The recovery of function of the PRP groups was better than that of the FS groups, although this did not reach statistical significance (P = .09). Electrophysiologic testing: there was a significantly better performance of the suture group when compared with the PRP and PPP without suture groups in nerve conduction velocity (P facial nerve axotomy models occurred when the nerve ends were sutured together. At the same time, the data demonstrated a measurable neurotrophic effect when PRP was present, with the most favorable results seen with PRP added to suture. There was an improved functional outcome with the use of PRP in comparison with FS or no bioactive

  10. SOLID RADIOACTIVE WASTE STORAGE TECHNOLOGIES: PERFORMANCE OF A POLYMER SEALANT COATING IN AN ARCTIC MARINE ENVIRONMENT

    Energy Technology Data Exchange (ETDEWEB)

    COWGILL,M.G.; MOSKOWITZ,P.D.; CHERNAENKO,L.M.; NAZARIAN,A.; GRIFFITH,A.; DIASHEV,A.; ENGOY,T.

    2000-06-14

    This first project, under the auspices of the Arctic Military Environmental Cooperation (AMEC) forum, Project 1.4-1 Solid Radioactive Waste Storage Technologies, successfully demonstrated the feasibility of using a polymer-based coating to seal concrete and steel surfaces from permanent radioactive contamination in an Arctic marine environment. A mobile, self-sufficient spraying device, was developed to specifications provided by the Russian Ministry of Defence Northern Navy and was deployed at the RTP Atomflot site, Murmansk, Russia. Demonstration coatings of Polibrid 705 were applied to concrete surfaces exposed to conditions ranging from indoor pedestrian usage to heavy vehicle passage and container handling in a loading bay. A large steel container was also coated with the polymer, filled with solid radwaste, sealed, and left out of doors and exposed to the full 12 month Arctic weather cycle. The field tests were accompanied by a series of laboratory qualification tests carried out at the research laboratory of ICC Nuclide in St. Petersburg. During the 12-month field tests, the sealant coating showed little sign of degradation except for a few chips and gouge marks on the loading bay surface that were readily repaired. Contamination resulting from radwaste handling was easily removed and the surface was not degraded by contact with the decontamination agents. In the laboratory testing, Polibrid 705 met all the Russian qualification requirements with the exception of flammability. In this last instance, it was decided to restrict application of the coating to land-based facilities. The Russian technical experts from the Ministry of Defence quickly familiarized themselves with the equipment and were able to identify several areas of potential improvement as deployment of the equipment progressed. The prime among these was the desirability of extending the range of the equipment through enlarged gasoline tanks (to permit extended operational times) and longer

  11. The use of FloSeal haemostatic sealant in the management of epistaxis: a prospective clinical study and literature review.

    Science.gov (United States)

    Wakelam, O C; Dimitriadis, P A; Stephens, J

    2017-01-01

    INTRODUCTION It is standard practice in the UK that if conservative measures or chemical cautery fail to control epistaxis, patients receive nasal packing which is often uncomfortable, requires admission and has well documented associated morbidity. Our study aims to evaluate the use of FloSeal haemostatic sealant in managing patients with epistaxis. MATERIALS AND METHODS Patients were identified from those referred with active epistaxis. A successful outcome was defined as complete haemostasis with FloSeal alone, with no further significant bleeding requiring admission or further interventions in the subsequent 7 days. Patients reported satisfaction using a ten-point visual analogue scale. Ear, nose and throat doctors recorded patient demographics, time to prepare FloSeal, length of stay, need for further treatment and adverse events on an electronic database. RESULTS 30 patients were enrolled in the study. The mean time to prepare FloSeal was 5 minutes. The success rate of FloSeal was 90%. The mean length of stay was 2.75 hours. The mean patient satisfaction with FloSeal was 8.4/10. No adverse events occurred. DISCUSSION FloSeal was found to be effective in controlling anterior epistaxis. There was a single case of posterior epistaxis which required operative management. The literature largely supports FloSeal in anterior epistaxis, but indicates sphenopalatine artery ligation as the definitive management of posterior epistaxis. CONCLUSIONS Our data support the use of FloSeal in patients with anterior epistaxis not controlled with conservative measures or chemical cautery. It was found to be easy to use, is well tolerated by patients and is efficient in financial terms.

  12. Avaliação clínica de um cimento de ionômero de vidro utilizado como selante oclusal: a clinical evaluation Use of a glass ionomer cement as an occlusal sealant

    Directory of Open Access Journals (Sweden)

    Pedro Cheque BERNARDO

    2000-03-01

    Full Text Available Sabendo-se do papel do flúor na Odontologia Preventiva, cada vez mais procuram-se materiais restauradores com propriedades de liberação deste íon. Dentre os selantes oclusais, grande expectativa existe em relação aos cimentos de ionômero de vidro, particularmente os fotopolimerizáveis, por possuírem melhores propriedades. O objetivo deste trabalho foi testar um destes cimentos, Vitremer (3M, aplicado em: combinação ou não com um adesivo. A avaliação foi realizada em 159 dentes, 6 e 12 meses após a aplicação do selante, observando-se sua retenção e a presença ou ausência de lesão de cárie. Concluiu-se que a técnica modificada, com adesivo, propiciou significativamente melhor retenção após 6 e 12 meses que a técnica convencional, não havendo diferença entre molares e pré-molares. Apenas um dente do grupo sem adesivo desenvolveu lesão de cárie após a perda do material.Since fluoride’s properties are widely known in the field of Preventive Dentistry, fluoride-releasing materials have been extensively investigated. Among the occlusal sealants, there is great expectation regarding the results that can be achieved with light-curing glass-ionomer cements due to their excellent properties. The aim of this study was to assess the use of one of these cements, Vitremer (3M as an occlusal sealant. The material was applied using two different techniques; either associated or not with an adhesive system. After 6 and 12 months of observation, an evaluation was performed in 159 teeth to verify its retention as well as the presence of caries lesions. The technique that included the adhesive system showed better retention than the conventional one. Total retention was 84.9% for the experimental technique and 37.2% for the conventional technique after 12 months. There was no difference between bicuspids and molars regarding retention. Caries lesion was observed in a single tooth, for which a total loss of material was observed

  13. Fixation of split-thickness skin graft using fast-clotting fibrin glue containing undiluted high-concentration thrombin or sutures: a comparison study.

    Science.gov (United States)

    Han, Hyun Ho; Jun, Daiwon; Moon, Suk-Ho; Kang, In Sook; Kim, Min Cheol

    2016-01-01

    For skin defects caused by full-thickness burns, trauma, or tumor tissue excision, skin grafting is one of the most convenient and useful treatment methods. In this situation, graft fixation is important in skin grafting. This study was performed to compare the effectiveness of skin graft fixation between high-concentration fibrin sealant and sutures. There have been numerous studies using fibrin sealant for graft fixation, but they utilized slow-clotting fibrin sealant containing less than 10 IU/mL thrombin. Twenty-five patients underwent split-thickness skin grafting using fast-clotting fibrin sealant containing 400 IU/mL thrombin, while 30 patients underwent grafting using sutures. Rates of hematoma/seroma formation, graft dislocation, graft necrosis, and graft take were investigated postoperatively. The graft surface area was calculated using Image J software (National Institutes of Health, Bethesda, MD, USA). After 5 days, rates of hematoma/seroma formation and graft dislocation were 7.84 and 1.29% in group I, and 9.55 and 1.45% in group II, respectively. After 30 days, rates of graft necrosis and graft take were 1.86 and 98.14% in group I, and 4.65 and 95.35% in group II. Undiluted fibrin sealant showed significantly superior results for all rates ( p  < 0.05) except graft dislocation. When high-concentration fast-clotting fibrin sealant was applied to skin grafts without dilution, no difficulty was experienced during surgery. Sealant showed superior results compared with sutures and had an excellent graft take rate. II.

  14. Avaliação da microinfiltração marginal e profundidade de penetração dos cimentos de ionômero de vidro utilizados como selantes oclusais Evaluation of marginal microleakage and depth of penetration of glass ionomer cements used as occlusal sealants

    Directory of Open Access Journals (Sweden)

    Marina de Lourdes Calvo Fracasso

    2005-09-01

    Full Text Available OBJETIVE: the aim of this study was to conduct an in vitro comparison of marginal microleakage (MM and the depth of penetration (DP of glass ionomer cements (GIC and a resin sealant (RS into occlusal pit and fissures. METHODS: for that purpose, 60 intact third molars were equally distributed to 5 groups: G1 - 37% phosphoric acid / Delton; G2 - 40% polyacrylic acid / Ketac-Molar / nail varnish; G3 - Fuji Plus conditioner / Fuji Plus/ nail varnish; G4 -37% phosphoric acid / Vitremer / Finishing gloss; G5 -37% phosphoric acid / Vitremer prepared with a 1:4 ratio of powder / Finishing gloss. The teeth were submitted to a thermal treatment corresponding to 300 cycles (15 sec, 5/55(0C, followed by complete coating with nail varnish, except for 1mm beyond the contour of the sealant. Afterwards, the teeth were immersed in 0.5% basic fuchsine for 24 hours. Thereafter, the teeth were sectioned in buccolingual direction and microscopically analyzed (150x magnification by means of predetermined scores. The results were subject to the Kruskal-Wallis test. RESULTS: there was no statistical difference between the materials tested in relation to the DP, being that all groups displayed nearly complete filling of the fissures. No sealant material was able to prevent dye penetration; however, the GICs provided better results of MM, with significant difference when compared to the RS. CONCLUSION: all materials investigated presented a satisfactory degree of penetration into the fissures; however, the glass ionomer cements displayed better performance in the marginal microleakage test compared to the resin sealant.OBJETIVO: o objetivo deste estudo foi comparar in vitro a microinfiltração marginal (MM e o grau de profundidade de penetração (DP de cimentos de ionômero de vidro (CIV e um selante resinoso (SR em fossas e fissuras oclusais. MATERIAIS E MÉTODOS: para tanto, 60 terceiros molares hígidos foram igualmente distribuídos em 5 grupos: G1- ácido fosf

  15. Electrophoretic deposition of Mn1.5Co1.5O4 on metallic interconnect and interaction with glass-ceramic sealant for solid oxide fuel cells application

    DEFF Research Database (Denmark)

    Smeacetto, Federico; De Miranda, Auristela; Cabanas Polo, Sandra

    2015-01-01

    Cr-containing stainless steels are widely used as metallic interconnects for SOFCs. Volatile Cr-containing species, which originate from the oxide formed on steel, can poison the cathode material and subsequently cause degradation in the SOFC stack. Mn1.5Co1.5O4 spinel is one of the most promisin...... between Mn1.5Co1.5O4 coated Crofer22APU and a new glass-ceramic sealant, after 500 h of thermal tests in air, thus suggesting that the spinel protection layer can effectively act as a barrier to outward diffusion of Cr. [All rights reserved Elsevier].......Cr-containing stainless steels are widely used as metallic interconnects for SOFCs. Volatile Cr-containing species, which originate from the oxide formed on steel, can poison the cathode material and subsequently cause degradation in the SOFC stack. Mn1.5Co1.5O4 spinel is one of the most promising...... coating materials due to its high electrical conductivity, good CTE match with the stainless steel substrate and an excellent chromium retention capability. In this work Mn1.5Co1.5O4 spinel coatings are deposited on Crofer22APU substrates by cathodic electrophoretic deposition (EPD) followed by sintering...

  16. Sealing of leaks in the bioshield cooling system of three research reactors

    International Nuclear Information System (INIS)

    May, R.; Taylor, M.F.

    1995-01-01

    Water leaks have occurred in the bioshield cooling system of three research reactors. These leaks have been plugged with a sealant based on a blend of a water-based resin and a bentonite-type clay originally developed for sealing similar leaks on power reactors. The mechanism of sealing and development testing of the sealant are described. Application of the sealant to the three reactors sealed the leaks. However, unlike experience with leaks in steel and aluminium systems, some leaks reappeared after several months service - albeit at a leak rate only a very small fraction of the original leak rate. The recurrent defects were readily retreated with sealant and hence, in these instances, the treatment is an effective maintenance procedure for any ageing reactor rather than a permanent cure. (orig.)

  17. Physical and thermal behaviour of Sr-La-Al-B-Si based SOFC glass sealants as function of SrO content and B2O3/SiO2 ratio in the matrix

    Science.gov (United States)

    Ojha, Prasanta Kumar; Rath, S. K.; Chongdar, T. K.; Gokhale, N. M.; Kulkarni, A. R.

    2011-05-01

    A series of SOFC glass sealants with composition SrO (x), La2O3 (15), Al2O3 (15), B2O3 (40 - x), and SiO2 (30) [x = 10, 15, 20, 25 and 30] (wt.%) [SLABS] are investigated for their structure property correlations at different compositions. Quantitative Fourier transform infrared spectroscopy shows structural rigidity with increasing SrO content, as demonstrate by an increase in the Si-O-Si/O-Si-O bending and B-O-B stretching frequencies. The role of SrO as a modifier dominates the control of the structure and behaviour of glasses compared with the effect of network formers, i.e., the B2O3/SiO2 ratio. Consequent to the structural changes, increasing substitution of B2O3 by SrO the glasses causes increases in the density, glass transition temperature and dilatometric softening point. On the other hand, the crystallization temperatures show a decreasing trend and the coefficient of thermal expansion increases with increase in substitution.

  18. 78 FR 27953 - Notification of Proposed Production Activity, CNH America, LLC, Subzone 59B, (Agricultural...

    Science.gov (United States)

    2013-05-13

    ... housings; vertical auger tubes; chopper drive gearbox accessories; cotton picker frames and cabs; and, non... components and materials sourced from abroad include: sealant; sealant paste; oil drain assemblies; rubber... axles; radiators; temperature sensors; pressure gauges; and, seats (duty rates range from free to 5...

  19. Quantification and Management of Manifest Occlusal Caries Lesions in Adults: A Methodological and a Clinical Study

    DEFF Research Database (Denmark)

    Bakhshandeh, Azam

    2010-01-01

    teeth with primary occlusal lesions. Randomization was performed in cases of more than one lesion in the same patient, so that the final material consisted of 60 resin sealed and 12 restored lesions. After 2-3 years, there was a drop-out of 15%; 2 patients did not show up for the control and 9...... extension of the lesions from baseline and the last control radiograph, there was scored caries progression beneath 5 (10%) of 49 sealants, caries regression beneath 1 (2%) sealant and unchanged lesion depth beneath 43 (88%) sealants and all restorations (p = 0.64). The methodological study included 110...

  20. Exploring the determinants of secular decreases in dental caries among Korean children.

    Science.gov (United States)

    Lee, Hye-Ju; Han, Dong-Hun

    2015-08-01

    The aim of this study was to determine the contributions of sealant and water fluoridation to the time trends in dental caries from 2003 to 2010. Data were from three waves of the Korean National Oral Health Surveys between 2003 and 2010, including a total of 23 059 children (11 889 boys and 11 170 girls) aged 8, 10, and 12 years. The impacts of sealant and water fluoridation on dental caries were obtained by logistic regression for each age group of children. The contributions of sealant and water fluoridation to the time trends in the prevalence of dental caries were examined by a series of logistic regression models, and changes in the adjusted odds ratios for each survey year were also calculated. Over the past 7 years, the prevalence of dental caries decreased dramatically. Although sealant had a significant impact on dental caries in each survey year, remarkable decreases in dental caries from 2003 to 2010 were not explained by the secular changes in the dental sealant or water fluoridation factor. We observed important population declines in dental caries in Korea in children aged 8-12 years; however, the likely causes for these secular trends remain to be determined. © 2015 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  1. Topical fibrin sealant versus intravenous tranexamic acid for reducing blood loss following total knee arthroplasty: A systematic review and meta-analysis.

    Science.gov (United States)

    Gao, Fuqiang; Ma, Jinhui; Sun, Wei; Guo, Wanshou; Li, Zirong; Wang, Weiguo

    2016-08-01

    Efficacy and safety of topical application of a fibrin sealant (FS) compared with intravenous administration of tranexamic acid (TXA) for reducing blood loss after total knee arthroplasty (TKA) is controversial. We undertook a meta-analysis to compare the effects of topical application of FS or intravenous administration of TXA on blood loss after TKA. PubMed, Medline, Embase, Web of Science and the Cochrane Library were searched to identify studies comparing FS with TXA for TKA patients. The mean difference (MD) of blood loss, hemoglobin value, and odds ratios (ORs) of transfusion requirements and adverse events in FS and TXA groups were pooled throughout the study. Relevant data were analyzed using RevMan v5.3. Five studies involving 359 patients were included (181 FS vs. 178 TXA). TXA use had a significantly lower prevalence of blood transfusion (OR = 3.14; 95% confidence interval (CI), 1.67 to 5.90, P = 0.0004) and higher hemoglobin level (MD = -1.23; 95% CI, -2.19 to -0.27, P = 0.01) than FS in the early postoperative period. No significant difference was seen in total blood loss between the two groups (MD = 198.06; 95% CI, -267.45 to 663.57; P = 0.40). There were no significant differences in adverse events, superficial infections, or deep-vein thrombosis among study groups. Our meta-analysis suggests that intravenous administration of TXA for patients undergoing TKA may reduce blood-transfusion requirements and maintain higher hemoglobin levels compared with topical application of FS in the early postoperative period. There were no significant differences in total calculated blood loss and prevalence of complications between the two groups. However, owing to the variation of included studies, no firm conclusions can be drawn. Copyright © 2016 IJS Publishing Group Ltd. Published by Elsevier Ltd. All rights reserved.

  2. 78 FR 37156 - Airworthiness Directives; Eurocopter France Helicopters

    Science.gov (United States)

    2013-06-20

    ... inspecting each jettisonable emergency exit window panel (window) for sealant, and removing any sealant that... prevent failure of the windows to jettison, so helicopter occupants can exit the aircraft during an... comments to the U.S. Department of Transportation, Docket Operations, M-30, West Building Ground Floor...

  3. Kebutuhan Fisur Silen Gigi Posterior pada Murid-Murid Sekolah Dasar di Kota Madya Medan

    Directory of Open Access Journals (Sweden)

    Lina Natamiharja

    2015-10-01

    Full Text Available The application of pit and fissure sealants is widely accepted practice in carious prevention, these materials were developed in an effort to prevent plaque, bacteria and carbohydrates penetrating pits and fissures of the teeth. Fissure sealants are effective in preventing occlusal carious in 33 out of every 100 teeth. The purpose of this study was to determine the needs of fissure sealant among the children age 6-13 years old. This study was carried out in two elementary schools. Samples was taken by sistematic random sampling based on age and sex. The totals of samples was 430 children. The needs of fissure sealant in the molars were quite high (36,75%, the highest percentage was in the lower first molar (49,64%, followed by the lower second molar (42,92%. In the premolars the needs was low (8,02%, the greatest needs was in the lower second premolar (15,79% followed by upper first premolar (7,50%.

  4. Sealing versus partial caries removal in primary molars: a randomized clinical trial

    NARCIS (Netherlands)

    Hesse, D.; Bonifácio, C.C.; Mendes, F.M.; Braga, M.M.; Imparato, J.C.P.; Raggio, D.P.

    2014-01-01

    Background The resin-based pit and fissure sealant is considered a successful tool in caries prevention, however there is a growing evidence of its use in controlling already established caries in posterior teeth. The aim of this clinical trial is to verify the efficacy of pit and fissure sealants

  5. Protocol for “Seal or Varnish?” (SoV trial: a randomised controlled trial to measure the relative cost and effectiveness of pit and fissure sealants and fluoride varnish in preventing dental decay

    Directory of Open Access Journals (Sweden)

    Chestnutt Ivor Gordon

    2012-11-01

    Full Text Available Abstract Background Dental caries remains a significant public health problem, prevalence being linked to social and economic deprivation. Occlusal surfaces of first permanent molars are the most susceptible site in the developing permanent dentition. Cochrane reviews have shown pit and fissure sealants (PFS and fluoride varnish (FV to be effective over no intervention in preventing caries. However, the comparative cost and effectiveness of these treatments is uncertain. The primary aim of the trial described in this protocol is to compare the clinical effectiveness of PFS and FV in preventing dental caries in first permanent molars in 6-7 year-olds. Secondary aims include: establishing the costs and the relative cost-effectiveness of PFS and FV delivered in a community/school setting; examining the impact of PFS and FV on children and their parents/carers in terms of quality of life/treatment acceptability measures; and examining the implementation of treatment in a community setting. Methods/design The trial design comprises a randomised, assessor-blinded, two-arm, parallel group trial in 6–7 year old schoolchildren. Clinical procedures and assessments will be performed at 66 primary schools, in deprived areas in South Wales. Treatments will be delivered via a mobile dental clinic. In total, 920 children will be recruited (460 per trial arm. At baseline and annually for 36 months dental caries will be recorded using the International Caries Detection and Assessment System (ICDAS by trained and calibrated dentists. PFS and FV will be applied by trained dental hygienists. The FV will be applied at baseline, 6, 12, 18, 24 and 30 months. The PFS will be applied at baseline and re-examined at 6, 12, 18, 24, and 30 months, and will be re-applied if the existing sealant has become detached/is insufficient. The economic analysis will estimate the costs of providing the PFS versus FV. The process evaluation will assess implementation and

  6. [Evaluation of the effect of one-step self etching adhesives applied in pit and fissure sealing].

    Science.gov (United States)

    Su, Hong-Ru; Xu, Pei-Cheng; Qian, Wen-Hao

    2016-06-01

    To observe the effect of three one-step self etching adhesive systems used in fit and fissure sealant and explore the feasibility of application in caries prevention in school. Seven hundred and twenty completely erupted mandibular first molars in 360 children aged 7 to 9 years old were chosen. The split-mouth design was used to select one side as the experimental group, divided into A1(Easy One Adper), B1(Adper Easy One), and C1(iBond SE).The contra lateral teeth served as A2,B2 and C2 groups (phosphoric acid). The retention and caries status were regularly reviewed .The clinical effect of the two groups was compared using SPSS19.0 software package for Chi - square test. At 3 and 6 months, pit and fissure sealant retention rate in A1 and A2, B1 and B2,C1 and C2 group had no significant difference. At 12 months, sealant retention in A1 and B1 group was significantly lower than A2 and B2 group (P0.05). At 24 months, sealant retention rate in A1, B1 and C1 group was significantly lower than A2, B2 and C2 group (P0.05). The clinical anticariogenic effect of three kinds of one-step etching adhesives and phosphoric acid etching sealant was similar .One-step self etching adhesive system was recommended for pit and fissure sealant to improve the students' oral health. The long-term retention rate of one-step self etching adhesive system was lower than the phosphoric acid method to long term observation is needed.

  7. 78 FR 76984 - Airworthiness Directives; Eurocopter France Helicopters

    Science.gov (United States)

    2013-12-20

    ... inspecting each jettisonable emergency exit window panel (window) for sealant, and removing any sealant that... prevent failure of the windows to jettison, so helicopter occupants can exit the aircraft during an... Office, M-30, West Building Ground Floor, Room W12-140, 1200 New Jersey Avenue SE., Washington, DC 20590...

  8. Requirements for Weatherproofing Thin Shell Concrete Roofs. Proceedings of the Conference of Building Research Institute, Division of Engineering and Industrial Research (Spring 1961).

    Science.gov (United States)

    National Academy of Sciences - National Research Council, Washington, DC.

    Topics discussed include--(1) requirements for weatherproofing and sealant materials for thin shell concrete roof, (2) effect of physical factors on weatherproofing of thin shell concrete roofs, (3) problems and limitations imposed by thin shell concrete roofs and their effect on weatherproofing and sealant materials, and (4) properties and uses…

  9. Effect of Gd2O3 doping on structure and boron volatility of borosilicate glass sealants in solid oxide fuel cells-A study on the La0.6Sr0.4Co0.2Fe0.8O3-δ (LSCF) cathode

    Science.gov (United States)

    Zhang, Qi; Tan, Shengwei; Ren, Mengyuan; Yang, Hsiwen; Tang, Dian; Chen, Kongfa; Zhang, Teng; Jiang, San Ping

    2018-04-01

    Boron volatility is one of the most important properties of borosilicate-based glass sealants in solid oxide fuel cells (SOFCs), as boron contaminants react with lanthanum-containing cathodes, forming LaBO3 and degrading the activity of SOFCs. Here, we report that the reaction between the volatile boron and a La0.6Sr0.4Co0.2Fe0.8O3-δ (LSCF) cathode during polarization can be significantly reduced by doping aluminoborosilicate glass with Gd2O3. Specifically, the Gd cations in glass with 2 mol.% Gd2O3 dissolve preferentially in the borate-rich environment to form more Gd-metaborate structures and promote the formation of calcium metaborate (CaB2O4); they also condense the B-O network after heat treatment, which suppresses poisoning by boron contaminants on the LSCF cathode. The results provide insights into design and development of a reliable sealing glass for SOFC applications.

  10. Superomniphobic Surfaces for Military Applications: Nano- and Micro-Fabrication Methods: Year Two Report

    Science.gov (United States)

    2011-12-01

    thread locking adhesive and advertised as waterproof) and Fluonova’s Fluorinated Polyurethane (2k 4FVBA) sealant (fluoropolymers adhesive/sealant for...bonding to most surfaces Advertised as being a water proof adhesive When cured, its consistency is very hard and unaffected by a variety of...polar fluorinated products; therefore, can only be used in small quantities. Yellow in colour . Not developed for coating/spray applications

  11. Study on durability for thermal cycle of planar SOFC

    Energy Technology Data Exchange (ETDEWEB)

    Ando, Motoo; Nakata, Kei-ichi; Wakayama, Sin-ichi [Tonen Corp., Saitama (Japan)] [and others

    1996-12-31

    TONEN CORPORATION has developed planar type SOFC since 1986. We demonstrated the output of 1.3 kW in 1991 and 5.1 kW in 1995. Simultaneously we have studied how to raise electric efficiency and reliability utilizing hydrogen and propane as fuel. Durability for thermal cycle is one of the most important problems of planar SOFC to make it more practical. The planar type SOFC is made up of separator, zirconia electrolyte and glass sealant. The thermal expansion of these components are expected to be the same value, however, they still possess small differences. In this situation, a thermal cycle causes a thermal stress due to the difference of the cell components and is often followed by a rupture in cell components, therefore, the analysis of the thermal stress should give us much useful information. The thermal cycle process consists of a heating up and cooling down procedure. Zirconia electrolyte is not bonded to the separator under the condition of the initial heating up procedure, and glass sealant becomes soft or melts and glass seals spaces between the zirconia and separator. The glass sealant becomes harder with the cooling down procedure. Moreover, zirconia is tightly bonded with separator below a temperature which is defined as a constraint temperature and thermal stress also occurs. This indicates that the heating up process relaxes the thermal stress and the cooling down increases it. In this paper, we simulated dependence of the stress on the sealing configuration, thermal expansion of sealant and constraint temperature of sealant glass. Furthermore, we presented SOFC electrical properties after a thermal cycle.

  12. Degree of conversion of resin-based materials cured with dual-peak or single-peak LED light-curing units.

    Science.gov (United States)

    Lucey, Siobhan M; Santini, Ario; Roebuck, Elizabeth M

    2015-03-01

    There is a lack of data on polymerization of resin-based materials (RBMs) used in paediatric dentistry, using dual-peak light-emitting diode (LED) light-curing units (LCUs). To evaluate the degree of conversion (DC) of RBMs cured with dual-peak or single-peak LED LCUs. Samples of Vit-l-escence (Ultradent) and Herculite XRV Ultra (Kerr) and fissure sealants Delton Clear and Delton Opaque (Dentsply) were prepared (n = 3 per group) and cured with either one of two dual-peak LCUs (bluephase(®) G2; Ivoclar Vivadent or Valo; Ultradent) or a single-peak (bluephase(®) ; Ivoclar Vivadent). High-performance liquid chromatography and nuclear magnetic resonance spectroscopy were used to confirm the presence or absence of initiators other than camphorquinone. The DC was determined using micro-Raman spectroscopy. Data were analysed using general linear model anova; α = 0.05. With Herculite XRV Ultra, the single-peak LCU gave higher DC values than either of the two dual-peak LCUs (P < 0.05). Both fissure sealants showed higher DC compared with the two RBMs (P < 0.05); the DC at the bottom of the clear sealant was greater than the opaque sealant, (P < 0.05). 2,4,6-trimethylbenzoyldiphenylphosphine oxide (Lucirin(®) TPO) was found only in Vit-l-escence. Dual-peak LED LCUs may not be best suited for curing non-Lucirin(®) TPO-containing materials. A clear sealant showed a better cure throughout the material and may be more appropriate than opaque versions in deep fissures. © 2014 BSPD, IAPD and John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  13. A unique heterologous fibrin sealant (HFS) as a candidate biological scaffold for mesenchymal stem cells in osteoporotic rats.

    Science.gov (United States)

    Orsi, Patrícia Rodrigues; Landim-Alvarenga, Fernanda Cruz; Justulin, Luis Antônio; Kaneno, Ramon; de Assis Golim, Marjorie; Dos Santos, Daniela Carvalho; Creste, Camila Fernanda Zorzella; Oba, Eunice; Maia, Leandro; Barraviera, Benedito; Ferreira, Rui Seabra

    2017-09-29

    The injection of mesenchymal stem cells (MSCs) directly into the bone of osteoporotic (OP) patients for rapid recovery has been studied worldwide. Scaffolds associated with MSCs are used to maintain and avoid cell loss after application. A unique heterologous fibrin sealant (HFS) derived from snake venom was evaluated for the cytotoxicity of its main components and as a three-dimensional biological scaffold for MSCs to repair a critical femur defect in osteoporotic rats. The cytotoxicity of HFS was assessed using a 3-(4,5-dimethyl-2-thiazolyl)-2,5-diphenyl-2H-tetrazoliumbromide (MTT) assay and transmission electron microscopy. The cells were cultured, characterized by flow cytometry and differentiated into the osteogenic lineage. Two-month-old rats underwent ovariectomy to induce OP. After 3 months, a 5 mm critical bone defect was made in the distal end of the rat femurs and filled with HFS; HFS + MSCs; and HFS + MSCs D (differentiated into the osteogenic lineage) to evaluate the effects. An injury control group (injury and no treatment) and blank control group (no injury and no treatment) were also included. The animals were observed at days 14 and 28 by microtomographic (micro-CT) analyses, histologic and biochemical analysis, as well as scanning electron microscopy. The results revealed that one of the compounds of HFS, the thrombin-like enzyme extracted from snake venom, had no cytotoxic effects on the MSCs. OP was successfully induced, as demonstrated by the significant differences in the levels of 17β-estradiol, Micro-CT analyses and alkaline phosphatase between the ovariectomized (OVX) and non-ovariectomized (NOVX) groups. The histological data revealed that at 14 days after surgery in both the OVX and NOVX animals, the HFS + CTMs and HFS + CTMsD showed a higher formation of bone cells at the site in relation to the control group (without treatment). Collagen formation was evidenced through bone neoformation in all treated and control groups

  14. A randomized clinical trial on the sealing of occlusal carious lesions

    DEFF Research Database (Denmark)

    Alves, Luana Severo; Giongo, Fernanda Cristina Mendes de Santa; Mua, Bruna

    2017-01-01

    This randomized clinical trial aimed to assess the efficacy of sealing occlusal carious lesions in permanent teeth. The sample consisted of 54 occlusal carious lesions in permanent molars and premolars of 49 patients aged 8-43 years (median: 19 years). The inclusion criteria comprised the presence...... of a cavity with no access allowing biofilm control. The maximum depth of the lesion was the middle third of the dentin thickness, as assessed by bitewing radiography. The teeth were randomly assigned to sealant treatment (n = 28) or restorative treatment (n = 26). Clinical and radiographic examinations were...... performed after 1 year and after 3-4 years. The outcomes depended on the clinical performance of the sealant/restoration and the control of caries progression observed radiographically. Survival analysis was performed to assess success rates. Over the 3-4 years of monitoring, 2 sealants were totally lost, 1...

  15. Leak isolation self-repairing tape for a water storage vessel and piping against holes

    International Nuclear Information System (INIS)

    Nagaya, Kosuke; Sekiguchi, Takahiro; Chen, Zhichao; Murakami, Iwanori

    2007-01-01

    A new type taping for a water storage vessel or piping is presented, in which water leakage is isolated automatically by its self-repairing mechanism against holes. The self-repairing unit (sealant layer) is consisting of three pieces of net with polymer particles inside lattices. Polymer particles, which expand their volume with water, is used for having self-repairing forces. In ordinary tapes, water leaks along the boundary between the tape and the vessel. In order to retain the leak isolation force, this article first discusses a method for making the sealant tape, then develops a method for fixing the sealant to the vessel. The portion of water leakage can be checked on this tape, and the method of detecting the hole or crack portion of the vessel is also presented by using the tape. (author)

  16. [Comparative studies on fissure sealing: composite versus Cermet cement].

    Science.gov (United States)

    Hickel, R; Voss, A

    1989-06-01

    Fifty two molars sealed with either composite or Cermet cement were compared. The composite sealant was applied after enamel etching using a rubber dam. Before sealing with Cermet cement the enamel was only cleaned with pumice powder and sodium hypochlorie and the material was applied without enamel etching. After an average follow-up of 1.6 years composite sealants proved to be significantly more reliable. Cermet cement sealings showed defects more frequently.

  17. Measuring quality of dental care: Caries prevention services for children.

    Science.gov (United States)

    Herndon, Jill Boylston; Tomar, Scott L; Catalanotto, Frank A; Rudner, Nancy; Huang, I-Chan; Aravamudhan, Krishna; Shenkman, Elizabeth A; Crall, James J

    2015-08-01

    The authors conducted a study to validate the following 3 evidence-based, process-of-care quality measures focused on dental caries prevention for children with an elevated risk of experiencing caries: sealants for 6- to 9-year-olds, sealants for 10- to 14-year-olds, and topical fluoride. Using evidence-based guidelines, the Dental Quality Alliance developed measures for implementation with administrative data at the plan and program levels. To validate the measures, the authors used data from the Florida and Texas Medicaid programs and Children's Health Insurance Programs and from national commercial dental benefit plans. Data were extracted from 414 randomly selected dental office records to validate the use of administrative data to accurately calculate the measures. The authors also assessed statistically significant variations in overall measure performance. Agreement between administrative data and dental records was 95% for sealants (κ = 0.82) and 90% for topical fluoride (κ = 0.78). Sensitivity and specificity were 90.7% and 88.5% for topical fluoride and 77.8% and 98.8% for sealants, respectively. Variation in overall measure performance was greatest for topical fluoride (χ(2) = 5,887.1; P caries received at least 2 topical fluoride applications during the reporting year. Although there was greater variation in performance for sealants for 6- to 9-year-olds (range, 21.0-31.3%; χ(2) = 548.6; P caries prevention process-of-care quality measures can be implemented feasibly and validly using administrative claims data. The measures can be used to assess, monitor, and improve the proportion of children with an elevated risk of experiencing dental caries who receive evidence-based caries prevention services. Copyright © 2015 American Dental Association. Published by Elsevier Inc. All rights reserved.

  18. Multiple lead seal assembly for a liquid-metal-cooled fast-breeder nuclear reactor

    International Nuclear Information System (INIS)

    Hutter, E.; Pardini, J.A.

    1977-01-01

    A reusable multiple lead seal assembly provides leak-free passage of stainless-steel-clad instrument leads through the cover on the primary tank of a liquid-metal-cooled fast-breeder nuclear reactor. The seal isolates radioactive argon cover gas and sodium vapor within the primary tank from the exterior atmosphere and permits reuse of the assembly and the stainless-steel-clad instrument leads. Leads are placed in flutes in a seal body, and a seal shell is then placed around the seal body. Circumferential channels in the body and inner surface of the shell are contiguous and together form a conduit which intersects each of the flutes, placing them in communication with a port through the wall of the seal shell. Liquid silicone rubber sealant is injected into the flutes through the port and conduit; the sealant fills the space in the flutes not occupied by the leads themselves and dries to a rubbery hardness. A nut, threaded onto a portion of the seal body not covered by the seal shell, jacks the body out of the shell and shears the sealant without damage to the body, shell, or leads. The leads may then be removed from the body. The sheared sealant is cleaned from the body, leads, and shell and the assembly may then be reused with the same or different leads. 3 claims, 6 figures

  19. Revegetation/rock cover for stabilization of inactive U-tailings sites

    International Nuclear Information System (INIS)

    Beedlow, P.A.; Cadwell, L.L.

    1982-01-01

    Soil placed over any sealant/barrier system can provide a protective mantle if the soil is not lost by erosion. Vegetation is an attractive choice for controlling erosion because it can provide an economic self-renewing cover that serves to reduce erosion by both wind and water. Vegetation alone, however, may not adequately stabilize the surface in extremely arid areas. In those areas, a properly designed surface treatment of rock cover, perhaps in conjunction with vegetation, may be necessary to stabilize the tailings surfaces. The objective of this program is to establish guidelines for surface stabilization that are compatible with sealant/barrier systems and that are suited to soils and climates at inactive uranium mill tailings sites. These guidelines will provide the means to estimate potential vegetation cover, potential erosion, effects of surface treatments on sealant/barrier systems, and costs of vegetation and rock covers. Methods for establishing vegetation on sealed tailings will also be provided

  20. Trans-sphenoidal treatment of postsurgical cerebrospinal fluid fistula: CT-guided closure

    International Nuclear Information System (INIS)

    Floris, R.; Salvatore, C.; Simonetti, G.

    1998-01-01

    Cerebrospinal fluid (CSF) leakage after trans-sphenoidal surgery is a troublesome complication with a risk of meningitis and pneumocephalus. We suggest CT-guided intrasphenoidal injection of fibrin sealant through a 12-gauge needle as a simple alternative to surgical management of CSF fistulae. We treated eight patients, operated via the trans-sphenoidal route (five pituitary adenomas, three craniopharyngiomas), for a postoperative CSF leak by CT-guided intrasphenoidal injection of fibrin sealant alone in three cases and fibrin sealant and autologous blood in 5. CT was obtained 10 days after the procedure in all cases. In four patients, the CSF leak was closed successfully at the first attempt. The procedure was repeated on the four remaining patients because only a reduction in leakage was obtained at the first attempt. This procedure preserves olfaction and avoids the risk of frontal lobe damage. It could therefore represent the treatment of choice in many cases of anterior cranial fossa postsurgical CSF leaks. (orig.) (orig.)

  1. Atraumatic restorative treatment in Brazilian schoolchildren: 12 months preliminary clinical results

    OpenAIRE

    Sacramento, Patrícia Almada; Department of Children’s Dentistry – Division of Pediatric Dentistry – Piracicaba Dental School – University of Campinas – Piracicaba – SP – Brazil.; Borges, Ana Flávia Sanches; Department of Operative Dentistry, Endodontics and Dental Materials – Bauru Dental School – University of São Paulo – Bauru – SP – Brazil.; Rodrigues, Raphaela Farias; Department of Operative Dentistry, Endodontics and Dental Materials – Bauru Dental School – University of São Paulo – Bauru – SP – Brazil.; Puppin-Rontani, Regina Maria; Department of Children’s Dentistry – Division of Pediatric Dentistry – Piracicaba Dental School – University of Campinas – Piracicaba – SP – Brazil.

    2014-01-01

    Objective: To evaluate the clinical efficacy between two GICs, Fuji IX (GC Int. Corp.) and Ketac Molar (3M ESPE), used in Atraumatic Restorative Treatments (ART).Materials and Methods: A total of 82 children age between 6 and 9 years old are included in this study. The materials criteria application followed the “split mouth” design, 71 restorations and 98 sealants were carried out with the Fuji IX in the left hemi arches and 70 restorations and 99 sealants were carried out with the Ketac Mol...

  2. Sealing versus Nonsealing: Cost-benefit analysis

    Directory of Open Access Journals (Sweden)

    Anshula N Deshpande

    2016-01-01

    Full Text Available Dental caries still remains the second most prevalent disease after common cold, out of which occlusal caries is the most profound one. In India, more than 40% of children are found to be affected by dental caries. Occlusal surfaces of the teeth are most susceptible sites for caries development due to their morphology. They are least benefited from fluoride application. Various efforts have been made by the preventive means to decline the rate of caries, one of which being sealant application. Sealants have come into existence long back since 1971 when first pit and fissure sealant Nuva-Caulk came into existence. There have been piles of literature stating the benefits that arrive from sealing the teeth. However, one crucial point that is being missed most of the times is the cost-effectiveness of the sealant. There are various schools of thoughts, regarding this that is controversial ones. Some of the analysts believe that always sealing may be a bit costlier, but it reduces subsequent dental treatments and hence saves money as well as time. However, some believe that why to unnecessarily seal the teeth in all cases even when the child is not at a risk to develop caries. Hence, we need to foresee both the sides of equation. For best clinical practice and decision-making, we need to have a balance of best evidence, clinical judgment, and the most important, patient needs and preferences.

  3. Volatilization of polycyclic aromatic hydrocarbons from coal-tar-sealed pavement

    Science.gov (United States)

    Van Metre, Peter C.; Majewski, Michael S.; Mahler, Barbara J.; Foreman, William T.; Braun, Christopher L.; Wilson, Jennifer T.; Burbank, Teresa L.

    2012-01-01

    Coal-tar-based pavement sealants, a major source of PAHs to urban water bodies, are a potential source of volatile PAHs to the atmosphere. An initial assessment of volatilization of PAHs from coal-tar-sealed pavement is presented here in which we measured summertime gas-phase PAH concentrations 0.03 m and 1.28 m above the pavement surface of seven sealed (six with coal-tar-based sealant and one with asphalt-based sealant) and three unsealed (two asphalt and one concrete) parking lots in central Texas. PAHs also were measured in parking lot dust. The geometric mean concentration of the sum of eight frequently detected PAHs (ΣPAH8) in the 0.03-m samples above sealed lots (1320 ng m-3) during the hottest part of the day was 20 times greater than that above unsealed lots (66.5 ng m-3). The geometric mean concentration in the 1.28-m samples above sealed lots (138 ng m-3) was five times greater than above unsealed lots (26.0 ng m-3). Estimated PAH flux from the sealed lots was 60 times greater than that from unsealed lots (geometric means of 88 and 1.4 μg m-2 h-1, respectively). Although the data set presented here is small, the much higher estimated fluxes from sealed pavement than from unsealed pavement indicate that coal-tar-based sealants are emitting PAHs to urban air at high rates compared to other paved surfaces.

  4. Caries progression in non-cavitated fissures after infiltrant application: a 3-year follow-up of a randomized controlled clinical trial

    Directory of Open Access Journals (Sweden)

    Camillo ANAUATE-NETTO

    Full Text Available Abstract Objectives To evaluate the efficacy of a conservative treatment to prevent the progression of caries using an infiltrant on non-cavitated pit and fissures. Material and Methods This controlled clinical trial selected 23 volunteers with clinically and radiographically non-cavitated occlusal caries among patients presenting a “rather low” to “very high” caries risk. Eighty-six teeth were randomly divided into two experimental groups: teeth receiving a commercial pit-and-fissure sealant (Alpha Seal-DFL and contralateral teeth receiving Icon infiltrant (DMG. Caries progression was monitored by clinical (laser fluorescence caries detection and radiographic examination at 12-month intervals over a period of 3 years of monitored caries progression. Probing the sealing materials to detect areas of retention was also used to evaluate marginal integrity. Results Statistical analysis showed no difference in caries progression using laser fluorescence caries detection when both materials were compared, regardless of the evaluation times (p>0.05. No significance was observed when the marginal sealant integrity of both materials was compared, regardless of the evaluation time (p0.05. SEM analysis exhibited a more homogeneous sealing for the infiltrant than obtained by the sealant. Conclusions The infiltrant was effective to prevent the caries progression in non-cavitated pit-and-fissures after 3 years of clinical evaluation, comparable with the conventional sealant. The infiltrant also presented better results in terms of caries progression at the 3-year evaluation time using the radiographic analysis.

  5. Caries progression in non-cavitated fissures after infiltrant application: a 3-year follow-up of a randomized controlled clinical trial

    Science.gov (United States)

    ANAUATE-NETTO, Camillo; BORELLI, Laurindo; AMORE, Ricardo; DI HIPÓLITO, Vinicius; D’ALPINO, Paulo Henrique Perlatti

    2017-01-01

    Abstract Objectives To evaluate the efficacy of a conservative treatment to prevent the progression of caries using an infiltrant on non-cavitated pit and fissures. Material and Methods This controlled clinical trial selected 23 volunteers with clinically and radiographically non-cavitated occlusal caries among patients presenting a “rather low” to “very high” caries risk. Eighty-six teeth were randomly divided into two experimental groups: teeth receiving a commercial pit-and-fissure sealant (Alpha Seal-DFL) and contralateral teeth receiving Icon infiltrant (DMG). Caries progression was monitored by clinical (laser fluorescence caries detection) and radiographic examination at 12-month intervals over a period of 3 years of monitored caries progression. Probing the sealing materials to detect areas of retention was also used to evaluate marginal integrity. Results Statistical analysis showed no difference in caries progression using laser fluorescence caries detection when both materials were compared, regardless of the evaluation times (p>0.05). No significance was observed when the marginal sealant integrity of both materials was compared, regardless of the evaluation time (p0.05). SEM analysis exhibited a more homogeneous sealing for the infiltrant than obtained by the sealant. Conclusions The infiltrant was effective to prevent the caries progression in non-cavitated pit-and-fissures after 3 years of clinical evaluation, comparable with the conventional sealant. The infiltrant also presented better results in terms of caries progression at the 3-year evaluation time using the radiographic analysis. PMID:28877284

  6. Experimental evaluation of clinical colon anastomotic leakage

    DEFF Research Database (Denmark)

    Pommergaard, Hans-Christian

    2014-01-01

    , whereas the eight-suture control anastomoses had a 0% leakage rate. Furthermore, the use of absorbable suture together with voluntarily ingested Temgesic in chocolate spread as analgesic regimen were feasible. This model may be used to test the leakage reducing potential of coating materials. STUDY 3...... experimental, in which designs were not comparable and many results were contradictory. In a clinical study, a non-significant benefit of fibrin sealant was found. Based on the available clinical and experimental data it was concluded that the fibrin-based sealants, such as Tisseel and Tachosil...

  7. Tritium sorption on protective coatings for concrete

    International Nuclear Information System (INIS)

    Miller, J.M.; Senohrabek, J.A.; Allsop, P.A.

    1992-11-01

    Because of the high sorption level of tritium on unprotected concrete, a program to examine the effectiveness of various concrete coatings and sealants in reducing tritium sorption was undertaken, and various exposure conditions were examined. Coatings of epoxy, polyurethane, bituminous sealant, bituminous sealant covered with polyvinylidene chloride wrap, alkyd paint, and sodium silicate were investigated with tritium (HTO) vapor concentration, humidity and contact time being varied. An exposure to HT was also carried out, and the effect of humidity on the tritium desorption rate was investigated. The relative effectiveness of the coatings was in the order of bituminous sealant + wrap > bituminous sealant > solvent-based epoxy > 100%-solids epoxy > alkyd paint > sodium silicate. The commercially available coatings for concrete resulted in tritium sorption being reduced to less than 7% of unprotected concrete. This was improved to ∼0.1% with the use of the Saran wrap (polyvinylidene chloride). The amount of tritium sorbed was proportional to tritium concentration. The total tritium sorbed decreased with an increase in humidity. A saturation effect was observed with increasing exposure time for both the coated and unprotected samples. Under the test conditions, complete saturation was not achieved within the maximum 8-hour contact time, except for the solvent-based epoxy. The desorption rate increased with a higher-humidity air purge stream. HT desorbed more rapidly than HTO, but the amount sorbed was smaller. The experimental program showed that HTO sorption by concrete can be significantly reduced with the proper choice of coating. However, tritium sorption on concrete and proposed coatings will continue to be a concern until the effects of the various conditions that affect the adsorption and desorption of tritium are firmly established for both chronic and acute tritium release conditions. Material sorption characteristics must also be considered in

  8. Systematic review of noninvasive treatments to arrest dentin non-cavitated caries lesions

    Science.gov (United States)

    de Assunção, Isauremi Vieira; da Costa, Giovanna de Fátima Alves; Borges, Boniek Castillo Dutra

    2014-01-01

    AIM: To systematically review the literature on the efficacy of noninvasive methods of arresting the progression of non-cavitated occlusal carious lesions in dentin. METHODS: The Medline/PubMed, LILACS, SciELO and Scopus databases were searched to identify relevant publications through to November 2013. Only clinical trials evaluating the ability of noninvasive methods to arrest the progression of occlusal non-cavitated carious lesions in dentin were included. Screening, data extraction and quality assessment were conducted independently and in duplicate. RESULTS: Of 167 citations identified, nine full text articles were screened and five were included in the analysis. All papers reported on occlusal fissure sealing using a self-curing glass ionomer (n = 1) or resin-based (n = 4) sealant. Only the use of resin-based sealant to obliterate occlusal fissures arrested the progression of non-cavitated occlusal carious lesions in dentin. CONCLUSION: Occlusal fissure sealing with a resin-based sealant may arrest the progression of non-cavitated occlusal dentinal caries. Further clinical trials with longer follow-up times should be performed to increase scientific evidence. PMID:24868513

  9. Atraumatic restorative treatment and minimal intervention dentistry.

    Science.gov (United States)

    Frencken, J E

    2017-08-11

    Too many people worldwide suffer from the consequences of untreated dentine carious lesions. This finding reflects the inability of the currently used traditional mode of treatments to manage such lesions. A change is needed. Dental training institutions should depart from the traditional 'drill and fill' treatments and embrace the holistic oral healthcare approach that is minimal intervention dentistry (MID) and includes within it minimally invasive operative skills. Dental caries is, after all, a preventable disease. The atraumatic restorative treatment (ART) concept is an example of MID. ART consists of a preventive (ART sealant) and a restorative (ART restoration) component. ART sealants using high-viscosity glass-ionomer (HVGIC) have a very high dentine carious lesion preventive effect. The survival rate of these sealants is not significantly different from that of sealants produced with resin. The survival rate of ART/HVGIC restorations matches those of amalgam and resin composite in single- and multiple-surface cavities in primary teeth and in single-surface cavities in permanent teeth. The principles of carious tissue removal within a cavity recommended by the International Caries Consensus Collaboration are in line with those of treating a cavity using ART. Owing to its good performance and the low levels of discomfort/pain and dental anxiety associated with it, ART and/or other evidence-based atraumatic care procedures should be the first treatment for a primary dentine carious lesion. Only if the use of ART is not indicated should other more invasive and less-atraumatic care procedures be used in both primary and permanent dentitions.

  10. Volatilization of polycyclic aromatic hydrocarbons from coal-tar-sealed pavement.

    Science.gov (United States)

    Van Metre, Peter C; Majewski, Michael S; Mahler, Barbara J; Foreman, William T; Braun, Christopher L; Wilson, Jennifer T; Burbank, Teresa L

    2012-06-01

    Coal-tar-based pavement sealants, a major source of PAHs to urban water bodies, are a potential source of volatile PAHs to the atmosphere. An initial assessment of volatilization of PAHs from coal-tar-sealed pavement is presented here in which we measured summertime gas-phase PAH concentrations 0.03 m and 1.28 m above the pavement surface of seven sealed (six with coal-tar-based sealant and one with asphalt-based sealant) and three unsealed (two asphalt and one concrete) parking lots in central Texas. PAHs also were measured in parking lot dust. The geometric mean concentration of the sum of eight frequently detected PAHs (ΣPAH(8)) in the 0.03-m samples above sealed lots (1320 ng m(-3)) during the hottest part of the day was 20 times greater than that above unsealed lots (66.5 ng m(-3)). The geometric mean concentration in the 1.28-m samples above sealed lots (138 ng m(-3)) was five times greater than above unsealed lots (26.0 ng m(-3)). Estimated PAH flux from the sealed lots was 60 times greater than that from unsealed lots (geometric means of 88 and 1.4 μg m(-2) h(-1), respectively). Although the data set presented here is small, the much higher estimated fluxes from sealed pavement than from unsealed pavement indicate that coal-tar-based sealants are emitting PAHs to urban air at high rates compared to other paved surfaces. Published by Elsevier Ltd.

  11. The influence of toothbrushing and coffee staining on different composite surface coatings.

    Science.gov (United States)

    Zimmerli, Brigitte; Koch, Tamara; Flury, Simon; Lussi, Adrian

    2012-04-01

    The aim of our study is to evaluate the performance of surface sealants and conventional polishing after ageing procedures. Eighty circular composite restorations were performed on extracted human molars. After standardised roughening, the restorations were either sealed with one of three surface sealants (Lasting Touch (LT), BisCover LV (BC), G-Coat Plus (GP) or a dentin adhesive Heliobond (HB)) or were manually polished with silicon polishers (MP) (n = 16). The average roughness (Ra) and colourimetric parameters (CP) (L*a*b*) were evaluated. The specimens underwent an artificial ageing process by thermocycling, staining (coffee) and abrasive (toothbrushing) procedures. After each ageing step, Ra and CP measurements were repeated. A qualitative surface analysis was performed with SEM. The differences between the test groups regarding Ra and CP values were analysed with nonparametric ANOVA analysis (α = 0.05). The lowest Ra values were achieved with HB. BC and GP resulted in Ra values below 0.2 μm (clinically relevant threshold), whereas LT and MP sometimes led to higher Ra values. LT showed a significantly higher discolouration after the first coffee staining, but this was normalised to the other groups after toothbrushing. The differences between the measurements and test groups for Ra and CP were statistically significant. However, the final colour difference showed no statistical difference among the five groups. SEM evaluation showed clear alterations after ageing in all coating groups. Surface sealants and dentin adhesives have the potential to reduce surface roughness but tend to debond over time. Surface sealants can only be recommended for polishing provisional restorations.

  12. Lamination cooling system formation method

    Science.gov (United States)

    Rippel, Wally E [Altadena, CA; Kobayashi, Daryl M [Monrovia, CA

    2009-05-12

    An electric motor, transformer or inductor having a cooling system. A stack of laminations have apertures at least partially coincident with apertures of adjacent laminations. The apertures define straight or angled cooling-fluid passageways through the lamination stack. Gaps between the adjacent laminations are sealed by injecting a heat-cured sealant into the passageways, expelling excess sealant, and heat-curing the lamination stack. Manifold members adjoin opposite ends of the lamination stack, and each is configured with one or more cavities to act as a manifold to adjacent passageway ends. Complex manifold arrangements can create bidirectional flow in a variety of patterns.

  13. Development of a new concept for controlling the thermal expansion of glass ceramic composites with tailored flowability demonstrated on the example high-temperature fuel cells; Entwicklung eines neuen Konzepts zur Steuerung der thermischen Ausdehnung von glaskeramischen Verbundwerkstoffen mit angepasster Fliessfaehigkeit am Beispiel der Hochtemperatur-Brennstoffzelle

    Energy Technology Data Exchange (ETDEWEB)

    Wanko, Eric

    2011-09-26

    In the joining technology, composite materials based on glass, glass ceramics (GC) and glass ceramic composites (GCC) become more and more important. Due to the increasingly required multi-functionality of the sealant material (for e.g. coefficient of expansion, flow ability, etc..), the developed sealant material used today is based on glass ceramic composites. With these, a good adhesion of the joining components, a good flow ability of the sealant material during the joining process and a good electrical insulation and mechanical strength have to be achieved. The joining process has to take place at temperatures < 900 C. The operation conditions of the SOFC are: 600 - 800 C under oxidizing as well as reducing atmospheric conditions. The present Thesis shows that, based on the use of database and thermochemical methods, sealing materials can be swiftly adjusted to all process and operation requirements. In order to do this especially, with regards of the thermo-mechanical properties of the developed sealant material (coefficient of expansion and flow ability) during the joining process, a new concept has been designed. Joining tests have been achieved on sandwich samples. The starting point of this new concept is a metal/glass matrix composite where the coefficient of expansion was controlled by dispersing a metal phase in the glass matrix. The newly developed concept is based on glass as a matrix and a crystalline phase as a filler material. It is essential that the crystalline phase and the glass matrix composition consist of the same thermodynamic co-existence area of the selected oxide base system. Here, the glass matrix has a lower liquidus temperature compared to the crystalline filler material, while the crystalline phase which consist of a higher coefficient of expansion is used alone to tailor the coefficient of expansion of the joining material. By incorporating a single crystalline phase into the selected glass matrix, the coefficient of expansion of

  14. [Bond strengths of absorbable polylactic acid root canal post with three different adhesives].

    Science.gov (United States)

    Pan, Hui; Cheng, Can; Hu, Jia; Liu, He; Sun, Zhi-hui

    2015-12-18

    To find absorbable adhesives with suitable bonding properties for the absorbable polylactic acid root canal post. To test and compare the bond strengths of absorbable polylactic acid root canal post with three different adhesives. The absorbable polylactic acid root canal posts were used to restore the extracted teeth, using 3 different adhesives: cyanoacrylates, fibrin sealant and glass ionomer cement. The teeth were prepared into slices for micro-push-out test. The bond strength was statistically analyzed using ANOVA. The specimens were examined using microscope and the failure mode was divided into four categories: cohesive failure between absorbable polylactic acid root canal posts and adhesives, cohesive failure between dentin and adhesives, failure within the adhesives and failure within the absorbable polylactic acid root canal posts. The bond strength of cyanoacrylates [(16.83 ± 6.97) MPa] and glass ionomer cement [(12.10 ± 5.09) MPa] were significantly higher than fibrin sealant [(1.17 ± 0.50) MPa], Padhesives was 25.0%, the cohesive failure between the dentin and the adhesives was 16.7%, the failure within the adhesives was 33.3%, and the failure within the absorbable polylactic acid root canal posts was 25.0%. In the group of fibrin sealant, the cohesive failure between the absorbable polylactic acid root canal posts and the adhesives was 66.7%, the cohesive failure between the dentin and the adhesives was 22.2%, the failure within the adhesives was 11.1%. In the group of glass ionomer cement, the cohesive failure between the absorbable polylactic acid root canal posts and the adhesives was 87.5%, the failure within the adhesives was 12.5%. The major failure mode in fibrin sealant and glass ionomer cement was the cohesive failure between the absorbable polylactic acid root canal posts and the adhesives. No major failure modes were found in the group of cyanoacrylates. The bond strength of fibrin sealant is low, which cannot meet the requirement of

  15. EFFECT OF SURFACE SEALING ON STAIN RESISTANCE OF A NANO-HYBRID RESIN COMPOSITE*

    Directory of Open Access Journals (Sweden)

    Günçe SAYGI

    2015-04-01

    Full Text Available Purpose: This study investigated the influence of sealant application on stain resistance of a nanohybrid resin composite compared to the efficacy of a bonding agent used as a surface sealant on prolonging color stability of the resin composite. Materials and Methods: 28 disc-shaped materials were prepared from a nano-hybrid resin composite Filtek Z550 and assigned to four groups: G1K: nonsealed; G2:Adper Single Bond; G3: Fortify ; G4: Biscover LV. After 24 h storage in distilled water at 37˚C, all specimens were subjected to thermocycling and immersed into coffee solution. Color measurements were performed using spectrophotometer (VITA Easyshade; Vident according to CIEL*a*b* system. Results: Color change values were significantly different among the groups in each evaluation period except for after thermocycling (p<0.05. For 7 days evaluation period, the difference between G3 and G4 group was statistically significant while G4 exhibited statistically significant differences (p<0.05 and p<0.0001 respectively compared to control (G1 in 14 day whereas no significant difference was found between GI and GII in 28-day evaluation period. However, ΔE values of sealed specimens (GIII, GIV differed significantly from non-sealed (GI specimens after 28 days of immersion in coffee solution (p<0.05 and p<0.0001 respectively. Conclusion: It may be concluded that using a bonding agent as a surface sealant does not increase stain resistance of resin composites of the sealants evaluated. Biscover LV showed the highest efficacy to prolong color stability of the resin composite.

  16. A Huge Morel-Lavallée Lesion Treated Using a Quilting Suture Method: A Case Report and Review of the Literature.

    Science.gov (United States)

    Seo, Bommie F; Kang, In Sook; Jeong, Yeon Jin; Moon, Suk Ho

    2014-06-01

    The Morel-Lavallée lesion is a collection of serous fluid that develops after closed degloving injuries and after surgical procedures particularly in the pelvis and abdomen. It is a persistent seroma and is usually resistant to conservative methods of treatment such as percutaneous drainage and compression. Various methods of curative treatment have been reported in the literature, such as application of fibrin sealant, doxycycline, or alcohol sclerodhesis. We present a case of a huge recurrent Morel-Lavallée lesion in the lower back and buttock region that was treated with quilting sutures, fibrin sealant, and compression, with a review of the literature. © The Author(s) 2014.

  17. Influência do selante de fibrina na cicatrização das pregas vocais de suínos Influence of selant fibrin on the wound healing of the pigs vocal folds

    Directory of Open Access Journals (Sweden)

    Karla Palma Portes

    2012-02-01

    Full Text Available Os selantes de fibrina ou cola de fibrina são produtos originários de proteínas do plasma humano que mimetizam a via final da rede de coagulação. Sua aplicação para estimular a cicatrização tem sido motivo de discussão na literatura mundial. O uso do selante de fibrina em fonocirurgia tem sido realizado de modo empírico. Não há trabalhos que investiguem a ação do selante de fibrina no espaço de Reinke. OBJETIVOS: Avaliar a interferência do uso da cola de fibrina no processo de cicatrização gerado pela manipulação cirúrgica em pregas vocais de suínos. MATERIAIS E MÉTODOS: Estudo prospectivo e experimental. Seis animais tiveram ambas as pregas vocais incisadas e em apenas uma delas foi aplicado o selante, sendo que a outra serviu de controle. Após 3 meses, os animais foram sacrificados e a contagem de colágenos realizada. RESULTADOS: O lado com aplicação de cola teve média de 27,8% contra 20,4% do lado sem aplicação de cola. CONCLUSÃO: A concentração de colágeno nas amostras onde o selante de fibrina foi aplicado é significativamente maior do que nas amostras onde não houve a aplicação. Portanto, a presença do selante de fibrina estimula a fibrogênese neste tecido.Fibrin sealants or fibrin glue are products made from human plasma proteins, which mimic the final pathway of the coagulation cascade. Its application to stimulate the healing process has been a topic of debate in the literature. The use of fibrin sealants in phonosurgery has been empirical; there have been no studies that investigate the action of fibrin sealant in Reinke's space. AIM: To evaluate the effect of fibrin glue in healing of the vocal folds of pigs after surgical manipulation. MATERIALS AND METHODS: This was a prospective and experimental study. Six animals had both vocal folds incised. Sealant was applied in one of them; the other served as a control. After three months, the animals were sacrificed and a collagen count was carried

  18. Effective and rapid sealing of coronary, aortic and atrial suture lines †.

    Science.gov (United States)

    Skorpil, Jiri; Paraforos, Alexandros; Mandak, Jiri; Cohn, William E; Hajek, Tomas; Friedrich, Ivan

    2015-06-01

    Cardiac surgical procedures carry a high risk of perioperative bleeding. Surgical sealants are often used to prevent suture line bleeding. PreveLeak™ is a surgical sealant composed of bovine serum albumin, a polyaldehyde cross-linker, and other components that forms a soft, flexible, water-tight, mechanical seal that is biocompatible and bioresorbable. A prospective, multicentre study evaluated PreveLeak use in 44 subjects undergoing 63 cardiac procedures, primarily coronary artery bypass grafting (n = 23/63, 36.5%) and aortic valve replacement (n = 19/63, 30.2%). PreveLeak was applied to 127 suture lines and the time to sealing evaluated upon clamp release. The primary safety endpoint was the incidence of significant bleeding, infections, neurological deficits and immune/inflammatory allergic responses within 6 weeks post-treatment; subjects were followed for 3 months. Immediate sealing was achieved at all sites in 42 of 44 subjects (95.5%) and 125 of 127 treatment sites (98.4%). There were nine primary safety events: eight infections and one transient neurological deficit. Most adverse events were mild (n = 46/71, 64.8%) or moderate (n = 18/71, 25.4%) in severity. One adverse event (transient vasospasm) was considered possibly sealant-related. One death occurred due to a cardiac arrest. PreveLeak prevented bleeding at 98.4% of treated sites and was well tolerated; adverse events were consistent with those commonly observed in subjects undergoing surgical procedures. These results compared favourably with published studies of other sealants. The observed prevention of bleeding is clinically important in cardiac surgical patients. A randomized, comparative study is justified to further evaluate PreveLeak and confirm the findings from this study. © The Author 2015. Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery. All rights reserved.

  19. Thermal stress analysis of a planar SOFC stack

    Science.gov (United States)

    Lin, Chih-Kuang; Chen, Tsung-Ting; Chyou, Yau-Pin; Chiang, Lieh-Kwang

    The aim of this study is, by using finite element analysis (FEA), to characterize the thermal stress distribution in a planar solid oxide fuel cell (SOFC) stack during various stages. The temperature profiles generated by an integrated thermo-electrochemical model were applied to calculate the thermal stress distributions in a multiple-cell SOFC stack by using a three-dimensional (3D) FEA model. The constructed 3D FEA model consists of the complete components used in a practical SOFC stack, including positive electrode-electrolyte-negative electrode (PEN) assembly, interconnect, nickel mesh, and gas-tight glass-ceramic seals. Incorporation of the glass-ceramic sealant, which was never considered in previous studies, into the 3D FEA model would produce more realistic results in thermal stress analysis and enhance the reliability of predicting potential failure locations in an SOFC stack. The effects of stack support condition, viscous behavior of the glass-ceramic sealant, temperature gradient, and thermal expansion mismatch between components were characterized. Modeling results indicated that a change in the support condition at the bottom frame of the SOFC stack would not cause significant changes in thermal stress distribution. Thermal stress distribution did not differ significantly in each unit cell of the multiple-cell stack due to a comparable in-plane temperature profile. By considering the viscous characteristics of the glass-ceramic sealant at temperatures above the glass-transition temperature, relaxation of thermal stresses in the PEN was predicted. The thermal expansion behavior of the metallic interconnect/frame had a greater influence on the thermal stress distribution in the PEN than did that of the glass-ceramic sealant due to the domination of interconnect/frame in the volume of a planar SOFC assembly.

  20. A School-Based Dental Program Evaluation: Comparison to the Massachusetts Statewide Survey.

    Science.gov (United States)

    Culler, Corinna S; Kotelchuck, Milton; Declercq, Eugene; Kuhlthau, Karen; Jones, Kari; Yoder, Karen M

    2017-10-01

    School-based dental programs target high-risk communities and reduce barriers to obtaining dental services by delivering care to students in their schools. We describe the evaluation of a school-based dental program operating in Chelsea, a city north of Boston, with a low-income and largely minority population, by comparing participants' oral health to a Massachusetts oral health assessment. Standardized dental screenings were conducted for students in kindergarten, third, and sixth grades. Outcomes were compared in bivariate analysis, stratified by grade and income levels. A greater percentage of Chelsea students had untreated decay and severe treatment need than students statewide. Yet, fewer Chelsea third graders had severe treatment need, and more had dental sealants. There was no significant difference in the percentage of Chelsea students having severe treatment need or dental sealants by income level. Students participating in our program do not have lower decay levels than students statewide. However, they do have lower levels of severe treatment need, likely due to treatment referrals. Our results confirm that school-based prevention programs can lead to increased prevalence of dental sealants among high-risk populations. Results provide support for the establishment of full-service school-based programs in similar communities. © 2017, American School Health Association.

  1. 76 FR 63282 - Foreign-Trade Zone 140-Flint, Michigan; Application for Subzone; Dow Corning Corporation (Silicon...

    Science.gov (United States)

    2011-10-12

    ... Corning facility (1,250 employees, 489 acres, 450,000 metric tons capacity) is located at 3901 S. Saginaw... products including elastomers, resins, fluids, silanes, polymers, gums, sealants and emulsions. Components...

  2. Asphalt emulsion sealing of uranium mill tailings. 1980 annual report

    International Nuclear Information System (INIS)

    Hartley, J.N.; Koehmstedt, P.L; Esterl, D.J.; Freeman, H.D.; Buelt, J.L.; Nelson, D.A.; Elmore, M.R.

    1981-05-01

    Studies of asphalt emulsion sealants conducted by the Pacific Northwest Laboratory have demonstrated that the sealants are effective in containing radon and other potentially hazardous material within uranium tailings. The laboratory and field studies have further demonstrated that radon exhalation from uranium tailings piles can be reduced by greater than 99% to near background levels. Field tests at the tailings pile in Grand Junction, Colorado, confirmed that an 8-cm admix seal containing 22 wt% asphalt could be effectively applied with a cold-mix paver. Other techniques were successfully tested, including a soil stabilizer and a hot, rubberized asphalt seal that was applied with a distributor truck. After the seals were applied and compacted, overburden was applied over the seal to protect the seal from ultraviolet degradation

  3. A new intermediate for the production of flexible stable polymers

    Science.gov (United States)

    Webster, J. A.

    1973-01-01

    Method of incorporating ether linkages into perfluoroalkylene segment of a dianydride intermediate yields intermediate that may be used in synthesis of flexible, stable polyimides for use as high-temperature, solvent-resistant sealants.

  4. 77 FR 31008 - Enforceable Consent Agreement Development for Two Cyclic Siloxanes; Solicitation of Interested...

    Science.gov (United States)

    2012-05-24

    ... No. 541-02-6) are high production volume chemicals having a wide variety of industrial, commercial..., soaps, detergents, adhesives, sealants, and rubber and plastic products. D4 is also used in processing...

  5. Oral Health Disparities as Determined by Selected Healthy People 2020 Oral Health Objectives for the United States, ...

    Science.gov (United States)

    ... dental caries varied by race and ethnicity and poverty level among children and adolescents. Figure 1. Prevalence ... income groups. Prevalence of dental sealants varied by poverty status among children, and varied by race and ...

  6. THE PROBLEMS AND PROSPECTS OF THE USE OF ELASTOMER SEALS FOR SEALING OF UNDERGROUND STRUCTURES

    Directory of Open Access Journals (Sweden)

    L. H. Politikova

    2007-10-01

    Full Text Available The research work on creation of effective rubber sealants for hermetic sealing of joints of underground structures from modular ferro-concrete and pig-iron including the underground tunnel casings is carried out.

  7. 77 FR 69824 - Certain New Chemicals; Receipt and Status Information

    Science.gov (United States)

    2012-11-21

    ...) Crosslinker in (G) Acetonoximino moisture cure sealant silane. formulaion. P-13-0020 10/11/2012 1/8/2013 Zeon... isomers of condensation products of substituted diazotized aminoanilines. P-12-0156 10/4/2012 9/21/2012 (G...

  8. Traditional preventive treatment options

    DEFF Research Database (Denmark)

    Longbottom, C; Ekstrand, K; Zero, D

    2009-01-01

    Preventive treatment options can be divided into primary, secondary and tertiary prevention techniques, which can involve patient- or professionally applied methods. These include: oral hygiene (instruction), pit and fissure sealants ('temporary' or 'permanent'), fluoride applications (patient...... options....

  9. 77 FR 61308 - Outer Continental Shelf Air Regulations; Consistency Update for California

    Science.gov (United States)

    2012-10-09

    ... Specific Source Standards (Adopted 07/06/76) Rule 74.1 Abrasive Blasting (Adopted 11/12/91) Rule 74.2... Oil Field Drilling Operations (Adopted 01/08/91) Rule 74.20 Adhesives and Sealants (Adopted 01/11/05...

  10. Color stability of sealed composite resin restorative materials after ultraviolet artificial aging and immersion in staining solutions.

    Science.gov (United States)

    Catelan, Anderson; Briso, André Luiz Fraga; Sundfeld, Renato Hermann; Goiato, Marcelo Coelho; dos Santos, Paulo Henrique

    2011-04-01

    The color alteration of resin-based materials is one of the most common reasons to replace esthetic dental restorations. This study assessed the influence of surface sealant (Biscover) on the color stability of nanofilled (Supreme XT) and microhybrid (Vit-l-escence and Opallis) composite resins after artificial aging. One hundred disc-shaped (6 × 1.5 mm) specimens were made for each composite resin. After 24 hours, all specimens were polished and sealant was applied to 50 specimens of each material. Baseline color was measured according to the CIE L*a*b* system using a reflection spectrophotometer. Ten specimens of each group were aged for 252 h in an ultraviolet (UV)-accelerated aging chamber or immersed for 4 weeks in cola soft drink, orange juice, red wine staining solutions or distilled water as control. Color difference (ΔE) after aging was calculated based on the color coordinates before (baseline) and after aging/staining treatment. Data were analyzed with 2-way ANOVA and Fisher's test (α=.05). The results showed significant changes in color after artificial aging in all the groups (Paging, and the cola soft drink. The lowest values of ΔE were found for specimens stored in distilled water. All composite resins showed some color alteration after the aging methods. The surface sealant did not alter the color stability of the tested materials. Copyright © 2011 The Editorial Council of the Journal of Prosthetic Dentistry. Published by Mosby, Inc. All rights reserved.

  11. Topical haemostatic agents for skin wounds: a systematic review

    Directory of Open Access Journals (Sweden)

    Ubbink Dirk T

    2011-07-01

    Full Text Available Abstract Background Various agents and techniques have been introduced to limit intra-operative blood loss from skin lesions. No uniformity regarding the type of haemostasis exists and this is generally based on the surgeon's preference. To study the effectiveness of haemostatic agents, standardized wounds like donor site wounds after split skin grafting (SSG appear particularly suitable. Thus, we performed a systematic review to assess the effectiveness of haemostatic agents in donor site wounds. Methods We searched all randomized clinical trials (RCTs on haemostasis after SSG in Medline, Embase and the Cochrane Library until January 2011. Two reviewers independently assessed trial relevance and quality and performed data analysis. Primary endpoint was effectiveness regarding haemostasis. Secondary endpoints were wound healing, adverse effects, and costs. Results Nine relevant RCTs with a fair methodological quality were found, comparing epinephrine, thrombin, fibrin sealant, alginate dressings, saline, and mineral oil. Epinephrine achieved haemostasis significantly faster than thrombin (difference up to 2.5 minutes, saline or mineral oil (up to 6.5 minutes. Fibrin sealant also resulted in an up to 1 minute quicker haemostasis than thrombin and up to 3 minutes quicker than placebo, but was not directly challenged against epinephrine. Adverse effects appeared negligible. Due to lack of clinical homogeneity, meta-analysis was impossible. Conclusion According to best available evidence, epinephrine and fibrin sealant appear superior to achieve haemostasis when substantial topical blood loss is anticipated, particularly in case of (larger SSGs and burn debridement.

  12. Comparative Study of Fibrin Sealent versus Use of Tackers in Inguinal Hernia Repair

    Directory of Open Access Journals (Sweden)

    Wasim Qadir Kar

    2015-09-01

    Full Text Available Purpose: To determine role and benefit of fibrin glue over tackers for mesh fixation in laparoscopic inguinal hernia repair. Backgroud: Mesh fixation by tackers may lead to many complications peroperatively like bleeding, increased hospital stay and overall more cost and later on chronic groin pain. Material and Methods: 60 inguinal hernia with age more than 18 years were taken and were divided in two groups; 30 patient group who underwent TAPP and 30 patient group who underwent TEPP. In 15 patients in both groups tackers were used and in other half fibrin glue was used for fixation of mesh using a 3mm catheter (Duplotip: Baxter Healthcare, which fits the Tisseel syringe. Results: The use of fibrin sealent has a distinct advantage in laparoscopic treatment of inguinal hernias compared with use of tackers as a method of mesh fixation. The use of fibrin sealant reduces the risk of post- and intraoperative complications, such as bleeding, seroma, chronic pain, has a lower incidence of postoperative neuralgia and provides an early faster return to social life. The recurrence rates do not vary much, but the operative time is slightly longer if the preparation time of the fibrin sealant is taken into consideration. In our study, we found a marginal difference in the cost of the two groups, fibrin sealant and stapled tackers. [Cukurova Med J 2015; 40(3.000: 457-465

  13. Assessing the effect of different operation techniques on postoperative duplex ultrasound quality after carotid endarterectomy.

    Science.gov (United States)

    Grambow, E; Heller, T; Wieneke, P; Weiß, C; Klar, E; Weinrich, M

    2018-01-01

    Duplex ultrasound is the first choice in diagnostics and surveillance of stenoses of the internal carotid arteries before and even after surgery. Therefore, the quality of duplex ultrasound is crucial to investigate these vascular pathologies. Aim of this study was the evaluation whether different surgical techniques affect the postoperative quality of duplex ultrasound. In a time period from January to May 2015 duplex ultrasound of the cervical vessels was performed in 75 patients after unilateral endarterectomy of the internal carotid artery at our department between 2006 and 2012. Thereby, the non-operated contralateral side served as a control. Study groups were defined by the surgical techniques of eversion- or thrombendarterectomy with patch plasty using different patch materials and/or a haemostatic sealant. Duplex ultrasound analysis included acoustic impedance, extinction of ultrasound, thickness of skin and individual anatomic aspects of the patients. Carotid endarterectomy itself reduced intravascular grey levels, skin thickness and increased extinction of duplex ultrasound when compared to the non-operated side of the neck. In contrast, neither the kind of chosen operative technique nor the use of different patch materials or the application of a haemostatic sealant showed an effect in this regards. Whereas carotid endarterectomy per se worsens the quality of postoperative duplex ultrasound, the different analysed surgical techniques as well as used patches and the application of a haemostatic sealant can be assumed to be equal regarding the quality of postoperative ultrasound.

  14. Reliability of intra-oral camera using teledentistry in screening of oral diseases – Pilot study

    Directory of Open Access Journals (Sweden)

    Kalyana Chakravarthy Pentapati

    2017-04-01

    Conclusion/recommendations: Intra-oral camera was shown to be a reliable tool to identify common oral diseases. Further studies involving applications like sealant retention, pre-malignant lesions, recurrent apthae, gingival recession and dental malocclusion and effectiveness in regular screening are needed.

  15. 75 FR 6403 - National Center for Health Statistics (NCHS), Classifications and Public Health Data Standards...

    Science.gov (United States)

    2010-02-09

    ...-10-PCS updates Application of Collagen Based Tissue Sealant Patches Biopsy of Soft Tissue Mass Central Venous Catheter Placement Using Intra-Atrial Electrocardiographic Guidance Circulating Tumor Cell Enumeration, Magnetic Closed Chest Intra-cardiac Mitral Valve Repair Continuous Glucose Monitoring Fat Graft...

  16. Evidence of Effectiveness of Current Therapies to Prevent and Treat Early Childhood Caries

    DEFF Research Database (Denmark)

    Twetman, Svante; Dhar, Vineet

    2015-01-01

    PURPOSE: The purpose of this paper was to systematically review the quality of evidence related to self-applied and professionally applied fluorides, antimicrobial agents, fissure sealants, temporary restorations, and restorative care for the prevention and management of early childhood caries (E...

  17. Ceramic sealants prepared by polymer pyrolysis

    Science.gov (United States)

    Hong, Sung Jin; Kim, Deug Joong; Yoo, Young Sung

    2011-02-01

    The formation and properties of ceramic seals for SOFC applications prepared by polymer pyrolysis are investigated. A mixture with polymethylsiloxane and fillers are pyrolyzed in a N2 atmosphere. The coefficient of thermal expansion of the ceramic composites was controlled by fillers with a high coefficient of thermal expansion such as AlCo. The morphology of the ceramic composites derived from the mixture with polymethylsiloxane and fillers is composed of fillers embedded in a Si-O-C glass matrix. The thermal expansion behavior and sealing characteristics are measured and discussed

  18. 78 FR 75352 - Proposed Data Collections Submitted for Public Comment and Recommendations

    Science.gov (United States)

    2013-12-11

    ...-based dental sealant programs; increase and maintain environmental systems level changes that support healthy behaviors, such as community water fluoridation; implement strategies that improve the delivery of... with state health departments to improve the oral health of the nation. Targeted efforts include...

  19. Effect of jointing work performed as an energy-saving measure

    Energy Technology Data Exchange (ETDEWEB)

    Brandt, A

    1983-12-01

    In order to establish the effect of replacing mortar joints by plastic or elastic sealants, an investigation of a number of multistory buildings has been carried out within the framework of the Danish Energy Research Programme EFP-81. An actual heat-saving effect could be established only in a few cases after replacement of windows and joints. The condition of the sealants was good after a few years of practical exposure. A surface cracking wich was not found to have any significant importance to the life of the joints was noted. The adhesion was good to tiles, wood and PVC. It was not possible to establish any decomposition of wooden windows owing to formation of condensate behind the tight seaplants placed at the outside, i.e. as a one-stage joint. It must be underlined that the investigation has only comprised brick built buildings.

  20. Silk sericin/polyacrylamide in situ forming hydrogels for dermal reconstruction.

    Science.gov (United States)

    Kundu, Banani; Kundu, Subhas C

    2012-10-01

    In situ forming tissue sealants are advantageous due to ease in application, complete coverage of defect site and assured comfort levels to patients. The interconnected three-dimensional hydrophilic networks perfectly manage typical dermal wounds by suitably scaffolding skin fibroblast, diffusing the nutrients, therapeutics and exudates while still maintaining an adequately moist environment. We evaluate the cell homing ability of semi-interpenetrating non-mulberry tropical tasar silk sericin/polyacrylamide hydrophilic network with a keen understanding of its network characteristics and correlation of protein concentration with the performance as cell scaffold. Interconnectivity of porous networks observed through scanning electron micrograph revealed pore sizes ranging from 23 to 52 μm. The enhanced β-sheet content with the increasing sericin concentration in far red spectroscopy study supported their corresponding improved compressive strength. These semi-interpenetrating networks were found to possess a maximum fluid uptake of 112% of its weight, hence preventing the accumulation of exudates at the wound area. The present systems appear to possess characteristics like rapid gelation (~5min) at 37 °C, 98% porosity enabling the migration of fibroblasts during healing (observed through confocal and scanning electron micrographs), cell adhesion together with the absence of any cyto-toxic effect suggesting its potential as in situ tissue sealants. The compressive strength up to 61 kPa ensured ease in handling even when wet. The results prove the suitability to use non-mulberry tasar cocoon silk sericin/polyacrylamide semi-interpenetrating network as a reconstructive dermal sealant. Copyright © 2012 Elsevier Ltd. All rights reserved.

  1. Knowledge and practices of caries prevention among Taiwanese dentists attending a national conference

    Directory of Open Access Journals (Sweden)

    Tzu-Hsien Lin

    2010-12-01

    Conclusions: A portion of Taiwanese dentists seemed to have limited up-to-date information about certain topics related to caries prevention. The frequency of treatments for caries prevention, such as topical fluoride and sealants, did not match the perceived effectiveness of these treatments by participants.

  2. Development and layout of a protocol for the field performance of concrete deck and crack sealers.

    Science.gov (United States)

    2009-09-01

    The main objective of this project was to develop and layout a protocol for the long-term monitoring and assessment of the performance of concrete deck and crack sealants in the field. To accomplish this goal, a total of six bridge decks were chosen ...

  3. Assessment of chemicals in construction products

    DEFF Research Database (Denmark)

    Krogh, Hanne; Olsen, Stig Irving

    2000-01-01

    . The reasons for that are lacks of product-specific emissions by manufacturing of chemical products, e.g. waterproofing systems and sealants. Besides, most LCA-models do not include assessments of emissions in working environment, in indoor environment or from disposal processes. It was therefore...

  4. The FINISH-3 Trial : A Phase 3, International, Randomized, Single-Blind, Controlled Trial of Topical Fibrocaps in Intraoperative Surgical Hemostasis

    NARCIS (Netherlands)

    Bochicchio, Grant V.; Gupta, Navyash; Porte, Robert J.; Renkens, Kenneth L.; Pattyn, Piet; Topal, Baki; Troisi, Roberto Ivan; Muir, William; Chetter, Ian; Gillen, Daniel L.; Zuckerman, Linda A.; Frohna, Paul A.

    BACKGROUND: This Phase 3, international, randomized, single-blind, controlled trial (FINISH-3) compared the efficacy and safety of Fibrocaps, a ready-to-use, dry-powder fibrin sealant containing human plasma-derived thrombin and fibrinogen, vs gelatin sponge alone for use as a hemostat for surgical

  5. The use of an internal teat sealant in combination with cloxacillin dry cow therapy for the prevention of clinical and subclinical mastitis in seasonal calving dairy cows.

    Science.gov (United States)

    Runciman, D J; Malmo, J; Deighton, M

    2010-10-01

    Cows (n=2,053) from 6 seasonally calving dairy herds were enrolled in a trial to compare the efficacy of 2 dry cow treatments. Cows received either a combination dry cow therapy of 600 mg of cloxacillin (CL) followed by an internal teat sealant (ITS) containing 2.6 g of bismuth subnitrate in all 4 quarters immediately following their final milking for the season, or only an intramammary infusion of 600 mg of CL. All cases of clinical mastitis were recorded and cultured during the first 150 d of lactation in each herd, and cow somatic cell count (SCC) was measured between 7 and 50 d postcalving. A large difference was found between treatment groups in the rate at which cows were diagnosed with clinical mastitis over the first 21 d of lactation, after which time the rate at which cows were diagnosed with clinical mastitis was similar between treatment groups. Analysis of the relative proportions of cows with clinical mastitis was performed at both the gland and cow levels. The relative risk (RR) of clinical mastitis diagnosed within 21, 30, and 100 d of calving in a gland treated with the ITS-CL combination was, respectively, 0.30 [95% confidence interval (CI)=0.21-0.44], 0.39 (0.28-0.53), and 0.58 (0.46-0.75) that of the CL group. An interaction between treatment and previous SCC was found when clinical mastitis was analyzed at the cow level. In a subset of cows that had low SCC in their previous lactation, the RR of mastitis in cows with the ITS-CL combination within 21, 30, and 100 d of calving was, respectively, 0.54 (95% CI=0.33-0.87), 0.57 (0.37-0.88), and 0.69 (0.50-0.99) that of cows that received only CL at drying off. In the subset of cows that had at least 1 high SCC in the previous lactation, the RR of mastitis in the ITS-CL combination group within 21, 30, and 100 d of calving was, respectively, 0.26 (95% CI=0.16-0.44), 0.37 (0.24-0.57), and 0.72 (0.55-0.96) that of the CL-only group. The ITS-CL combination of dry cow treatments was associated with a

  6. Effects of antibiotic dry-cow therapy and internal teat sealant on milk somatic cell counts and clinical and subclinical mastitis in early lactation.

    Science.gov (United States)

    Golder, H M; Hodge, A; Lean, I J

    2016-09-01

    The objective of this study was to determine the efficacy of an internal teat sealant (TS; Teatseal; Zoetis Australia, Silverwater, NSW, Australia), when used in combination with antibiotic dry-cow therapy (ADCT) administered at dry-off, on milk individual somatic cell count (ISCC), milk production and components, and the incidence of clinical and subclinical mastitis in dairy cows up to 60 d after calving, when compared with ADCT only. Multiparous Holstein, Jersey, or Holstein cross cows (n=2,200) from 8 farms in southern and eastern Australia were randomly assigned to treatment of all 4 quarters with ADCT alone or with ADCT plus TS (ADCT + TS) at dry-off in this randomized, multisite clinical trial. Individual milk yield, fat and protein percentages, and ISCC were measured at intervals of 14±3 d after calving for the first 60 d of lactation. The first measurement occurred between 10 and 24 d after calving. Clinical mastitis and health events were recorded from dry-off to 60 d of lactation. Milk samples were collected from first cases of clinical mastitis and subjected to bacteriology. Treatment and the interaction of treatment by time did not affect milk yield, ISCC weighted by milk yield, or fat and protein percentages. Treatment with ADCT + TS decreased geometric mean ISCC compared with treatment with ADCT alone over the first 60 d of lactation. Geometric mean ISCC (×10(3) cells/mL) was 32.0 [95% confidence interval (CI): 26.8 to 38.3] and 43.5 (95% CI: 36.2 to 52.1) for ADCT + TS and ADCT alone, respectively. The odds of at least 1 case of subclinical mastitis (ISCC ≥250,000 cells/mL) were 1.9 times higher (95% CI: 1.4 to 2.6) with ADCT alone in the first 60 d of lactation compared with ADCT + TS. Use of ADCT + TS reduced the estimated incidence of at least 1 case of subclinical mastitis on all 8 farms, compared with use of ADCT alone. Only 4 cows that calved 40 to 100 d after dry-off had a first case of clinical mastitis in the dry period. Five percent of

  7. Bioactivity and stability of endogenous fibrogenic factors in platelet-rich fibrin

    DEFF Research Database (Denmark)

    Lundquist, R.; Dziegiel, M.H.; Agren, M.S.

    2008-01-01

    Platelet-rich fibrin (PRF) is an autologous fibrin sealant (FS) enriched with a platelet concentrate (> 1,000,000 platelets/microL) produced by the automated Vivostat system and used to enhance wound healing. The effects of PRF were compared with supernatant from thrombin-activated platelet conce...

  8. Prevalence of Dental Caries and Periodontal Disease in Mexican American Children Aged 5 to 17 Years: Results from Southwestern HHANES, 1982-83.

    Science.gov (United States)

    Ismail, Amid L.; And Others

    1987-01-01

    Dental caries and periodontal disease in Mexican American children of the southwestern United States occur mainly in molars, lending strong support for the use of fissure sealants as a preventive procedure. This study also reports on the prevalence of fillings decay and gingivitis in this population. (VM)

  9. Feracrylum does not Reduce the Incidence of Seroma Formation ...

    African Journals Online (AJOL)

    different unsuccessful procedures have been tried to prevent seroma. ... mastectomy. Among them are; shoulder immobilization, use of fibrin sealant, various drain regimens and dead space obliteration with no success. Feracrylum, a coagulant, is an incomplete iron salt of ... established in previous studies that with use of.

  10. Cyanoacrylate Skin Microsealant for Preventing Surgical Site Infection after Vascular Surgery : A Discontinued Randomized Clinical Trial

    NARCIS (Netherlands)

    Vierhout, Bastiaan P.; Ott, Alewijn; Reijnen, Michel M. P. J.; Oskam, Jacques; Ott, Alewijn; van den Dungen, Jan J. A. M.; Zeebregts, Clark J.

    Background: Surgical site infections (SSI) after vascular surgery are related to substantial morbidity. Restriction of bacterial access to the site of surgery with a cyanoacrylate sealant is a new concept. We performed a randomized clinical trial to assess the effect of the sealing of skin with a

  11. The use of a 'bleach-etch-seal' deproteinization technique on MIH affected enamel.

    Science.gov (United States)

    Gandhi, Shan; Crawford, Peter; Shellis, Peter

    2012-11-01

    To ascertain whether deproteinization pretreatment of molar-incisor hypomineralization (MIH) enamel affects resin sealant infiltration. Thirty one extracted MIH teeth were divided into three sections and randomly allocated into the Control (etch and FS), Treatment 1 (5% NaOCl, etched and fissure sealed), and Treatment 2 (5% NaOCl and fissure sealed with no etch) groups. Two hundred seventy nine sealant tag/enamel grade observations were recorded by scanning electron microscopy. Control and Treatment 1 were similar in their outcomes, and Treatment 2 was markedly different. There was no statistical evidence to suggest that there was any difference between Treatment 1 and the Control Treatment (95% CI, 0.52, 1.51; P = 0.6). There was a marked difference between Treatment 2 and the Control Treatment (95% CI, 0.07, 0.25; P MIH enamel, regardless of which of the three treatments was used. © 2012 The Authors. International Journal of Paediatric Dentistry © 2012 BSPD, IAPD and Blackwell Publishing Ltd.

  12. Characterization of C/SiC Ceramic Matrix Composites (CMCs) with Novel Interface Fiber Coatings

    Science.gov (United States)

    Petko, Jeanne F.; Kiser, J. Douglas; Gray, Hugh R. (Technical Monitor)

    2002-01-01

    Ceramic Matrix Composites (CMCs) are attractive candidate aerospace materials due to their high specific strength, low density and high temperature capabilities. The National Aeronautics and Space Administration (NASA) is pursuing the use of CMC components in advanced Reusable Launch Vehicle (RLV) propulsion applications. Carbon fiber-reinforced silicon carbide (C/SiC) is the primary material of interest for a variety of RLV propulsion applications. These composites consist of high-strength carbon fibers and a high modulus, oxidation resistant matrix. For RLV propulsion applications, environmental durability will be critical. Two types of carbon fibers were processed with both standard (pyrolytic carbon) and novel (multilayer and pseudoporous) types of interface coatings as part of a study investigating various combinations of constituents. The benefit of protecting the composites with a surface sealant was also investigated. The strengths, durability in oxidizing environments, and microstructures of these developmental composite materials are presented. The novel interface coatings and the surface sealant show promise for protecting the carbon fibers from the oxidizing environment.

  13. A Novel SOFC/SOEC Sealing Glass with a Low SiO2 Content and a High Thermal Expansion Coefficient

    DEFF Research Database (Denmark)

    Kiebach, Wolff-Ragnar; Agersted, Karsten; Zielke, Philipp

    2017-01-01

    the amount of Si emission, a low Si containing sealing glass (chemical composition: 50 mol% CaO, 20 mol% ZnO, 20 mol% B2O3 and 10 mol% SiO2) was developed at DTU. In this work, the results from thermal characterization, the crystallization behavior of the glass and the long-term stability and adhesion......Solid oxide cells require seals that can function in harsh, elevated temperature environments. In addition, a low Si content can be advantageous, since Si impurities from the glass sealant can be transported to the active fuel electrode and poison the Ni-YSZ triple phase boundaries. To reduce...... behavior of the glass were studied under SOFC and SOEC relevant conditions. The glass-ceramic sealant performed well over 400 h, and no cell degradation or leakage related to the seal was found, indicating that the developed glass system is applicable for the use in SOFC/SOEC stacks....

  14. Decision tree analysis to evaluate dry cow strategies under UK conditions.

    Science.gov (United States)

    Berry, Elizabeth A; Hogeveen, Henk; Hillerton, J Eric

    2004-11-01

    Economic decisions on animal health strategies address the cost-benefit aspect along with animal welfare and public health concerns. Decision tree analysis at an individual cow level highlighted that there is little economic difference between the use of either dry cow antibiotic or an internal teat sealant in preventing a new intramammary infection in a cow free of infection in all quarters of the mammary gland at drying off. However, a potential net loss of over ł20 per cow might occur if the uninfected cow was left untreated. The only economically viable option, for a cow with one or more quarters infected at drying off, is antibiotic treatment, although a loss might still be incurred depending on the pathogen concerned and the cure rates achievable. There was a net loss for cows with quarters infected with Corynebacterium spp. at drying off, for both the teat sealant and untreated groups (ł22 and ł48, respectively) with only antibiotic-treated cows showing a gain.

  15. Correct Diagnosis Provides Relief for Those with Dry Mouth

    Science.gov (United States)

    ... temporomandibular disorders (TMD). More What is Baby Bottle Tooth Decay? The History of Dental Advances When Should My Child First See a ... of baking soda and water." Applying sealants to teeth can help protect against cavities brought on by tooth decay. If the problem becomes serious, a dentist can ...

  16. Millimeter Wave-based Fatigue Countermeasure Research for Improving Performance and Prolonging Combat Effectiveness of Warfighters

    Science.gov (United States)

    2011-04-07

    5 silk suture attached to the arm of an Aurora Scientific model 300 servo-motor to register contractions. The distal end of the muscle is held taut...that use specially designed glass sleeves and Sylgard (184 silicone elastomer, Dow Corning Corp.) sealant to allow for precise positioning of the

  17. Intercalated Graphite Fiber Conductor.

    Science.gov (United States)

    1980-12-01

    melting solders, used as electrical contacts as well as sealants for the glass containers described earlier, and high temperature gold varnish , used on...corrosion resistant to fluorine containing chemicals. Since the moisture permeability of the TFE is much less than that of the FEP, attempts were made to

  18. 21 CFR 872.6070 - Ultraviolet activator for polymerization.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Ultraviolet activator for polymerization. 872.6070 Section 872.6070 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES... ultraviolet radiation intended to polymerize (set) resinous dental pit and fissure sealants or restorative...

  19. 76 FR 3561 - Airworthiness Directives; The Boeing Company Model 777-200 and -300 Series Airplanes Equipped...

    Science.gov (United States)

    2011-01-20

    ... studs, blanket studs, and temporary fasteners; replacement of sealant if necessary; and related... installed Doing a detailed inspection of the T/R panel wall inner bolt holes for elongation Doing a general... click bond stud, blanket stud, and temporary fastener is loose, damaged, or missing Doing an NDT (eddy...

  20. Approximal sealings on lesions in neighbouring teeth requiring operative treatment: an in vitro study.

    Science.gov (United States)

    Cartagena, Alvaro; Bakhshandeh, Azam; Ekstrand, Kim Rud

    2018-02-07

    With this in vitro study we aimed to assess the possibility of precise application of sealant on accessible artificial white spot lesions (WSL) on approximal surfaces next to a tooth surface under operative treatment. A secondary aim was to evaluate whether the use of magnifying glasses improved the application precision. Fifty-six extracted premolars were selected, approximal WSL lesions were created with 15% HCl gel and standardized photographs were taken. The premolars were mounted in plaster-models in contact with a neighbouring molar with Class II/I-II restoration (Sample 1) or approximal, cavitated dentin lesion (Sample 2). The restorations or the lesion were removed, and Clinpro Sealant was placed over the WSL. Magnifying glasses were used when sealing half the study material. The sealed premolar was removed from the plaster-model and photographed. Adobe Photoshop was used to measure the size of WSL and sealed area. The degree of match between the areas was determined in Photoshop. Interclass agreement for WSL, sealed, and matched areas were found as excellent (κ = 0.98-0.99). The sealant covered 48-100% of the WSL-area (median = 93%) in Sample 1 and 68-100% of the WSL-area (median = 95%) in Sample 2. No statistical differences were observed concerning uncovered proportions of the WSL-area between groups with and without using magnifying glasses (p values ≥ .19). However, overextended sealed areas were more pronounced when magnification was used (p = .01). The precision did not differ between the samples (p = .31). It was possible to seal accessible approximal lesions with high precision. Use of magnifying glasses did not improve the precision.

  1. Effect of BioGlue on the incidence of pancreatic fistula following pancreas resection.

    Science.gov (United States)

    Fisher, William E; Chai, Christy; Hodges, Sally E; Wu, Meng-Fen; Hilsenbeck, Susan G; Brunicardi, F Charles

    2008-05-01

    Despite numerous modifications of surgical technique, pancreatic fistula remains a serious problem and occurs in about 10% of patients following pancreas resection. BioGlue is a new sealant that creates a flexible mechanical seal within minutes independent of the body's clotting mechanism. Application of BioGlue sealant will reduce the incidence of pancreatic fistula following pancreas resection. A retrospective cohort study was performed with 64 patients undergoing pancreas resection. BioGlue sealant was applied to the pancreatic anastomosis (Whipple) or resection margin (distal pancreatectomy) in 32 cases. Factors that could affect the rate of postoperative pancreatic fistula were recorded. Pancreatic fistula was defined as greater than 50 ml of drain output with an amylase content greater than three times normal serum value after postoperative day 10. To improve the sensitivity of our study, we also examined pancreatic fistula with a strict definition of any drain output on or after postoperative day 3 with a high amylase content and graded the fistulas in terms of clinical severity. Grade A leaks were defined as subclinical. Grade B leaks required some response such as making the patient nil per os, parenteral nutrition, octreotide, antibiotics, or a prolonged hospital stay. Grade C leaks were defined as serious and life threatening. They were associated with hemorrhage, sepsis, resulted in deterioration of other organ systems, and mandated intensive care. Comparisons between the two groups were made using the chi-square test or Fisher's exact test for categorical variables and by the Wilcoxon rank-sum test for continuous variables. P values of 0.05 or less were deemed statistically significant. There were no differences between the patients who received BioGlue and the control cohort in terms of comorbid conditions, tumor location, texture of the pancreas, size of the pancreatic duct, or surgical technique. By the common definition, pancreatic fistula occurred

  2. Air quality in a simulated office environment as a result of reducing pollution sources and increasing ventilation

    DEFF Research Database (Denmark)

    Wargocki, Pawel; Bako-Biro, Zsolt; Clausen, Geo

    2002-01-01

    Air quality was studied in an office space classified as low-polluting and ventilated with outdoor air at a rate of 1 h-1. The pollution load in the space was changed by introducing or removing common building-related indoor pollution sources (linoleum, sealant and wooden shelves with books and p...

  3. 75 FR 35977 - Significant New Use Rules on Certain Chemical Substances

    Science.gov (United States)

    2010-06-24

    ... polymers with amide or imide links; a crosslinker for epoxy type coatings, adhesives and sealants; a crosslinker for epoxy type composites; a monomer for urea and urethane urea polymers used in coatings; a... substances will be used as curing agents for epoxy coating systems. Based on test data on analogous aliphatic...

  4. 77 FR 71731 - Airworthiness Directives; The Boeing Company

    Science.gov (United States)

    2012-12-04

    ... forward dry bay; a detailed and high frequency eddy current (HFEC) inspection for cracking, etching, or... eddy 8 work-hours x $85 per hour = $680.... 0 680 current inspection. Clean and restore sealant, primer... contacting the manufacturer for repair instructions and doing the repair. The compliance time for the initial...

  5. Evaluation of glass ionomer sealants placed according to the ART approach in a community with high caries experience: 1-year follow-up Avaliação de selantes ionoméricos realizados pela técnica do ART em comunidade com alta experiência de cárie: 1 ano de acompanhamento

    Directory of Open Access Journals (Sweden)

    Ana Luiza Falavinha Vieira

    2006-08-01

    Full Text Available The aim of this study was to investigate the retention rates and effect on occlusal caries incidence of two glass ionomers used as sealants, placed according to the Atraumatic Restorative Treatment (ART approach, in a high caries-risk community. A total of 150 newly erupted first molars of 42 schoolchildren, between 6-8 years of age were selected. The teeth were divided into two groups: experimental and control groups. In the experimental group, 76 teeth were sealed using Vidrion R-SS White (conventional GIC and in the control group, 74 teeth were sealed using ChemFlex-Dentsply (high-viscosity conventional GIC. The sealants were applied by one operator following the "press finger technique", described in the ART-WHO manual. Two calibrated independent examiners carried out the evaluation according to the ART criteria. The intra and inter-examiner agreements were 0.84 and 0.81, respectively. Data were submitted to Mann-Whitney and Chi-square tests (pO objetivo deste trabalho foi avaliar o índice de retenção e o efeito na incidência de cárie oclusal de dois selantes ionoméricos realizados pela técnica do Tratamento Restaurador Atraumático (ART em comunidades com alto índice de cárie. Foram selecionados 150 primeiros molares recém-erupcionados de 42 escolares, entre 6-8 anos de idade. Os dentes foram divididos em dois grupos: experimental e controle. No grupo experimental 76 dentes foram selados com Vidrion R-SSWhite (CIV-convencional e no grupo controle, 74 dentes foram selados com ChemFlex-Dentsply (CIV-alta viscosidade. Os selantes foram realizados por apenas um operador pela técnica da "pressão digital", descrita no manual de ART da OMS. Dois avaliadores independentes e calibrados segundo os critérios do ART realizaram a avaliação. A concordância intra e inter-examinadores foi de 0,84 e 0,81, respectivamente. Os resultados foram submetidos aos testes Mann-Whitney e Q-quadrado (p<0,05. Após um ano, 136 (90,7% selante foram

  6. 77 FR 40033 - Certain New Chemicals; Receipt and Status Information

    Science.gov (United States)

    2012-07-06

    .../02/2012 07/30/2012 CBI (G) Coating (G) Acid anhydride, additive. polymer with aromatic isocyanate and... pigment. earth doped. P-12-0345 05/09/2012 08/06/2012 CBI (G) Coating for (G) Ultra violet- open non...) Crosslinker (S) 2-propenone, Corporation. in moisture o,o',o- cure sealant (ethylsilylidyne) formulation...

  7. Minimally Invasive Dentistry

    Science.gov (United States)

    ... all contributors to decay. Your dentist will then use strategies to prevent or reduce your risk for tooth decay. For instance, if ... require anesthesia. It resembles microscopic sand blasting and uses a stream of air combined with a super-fine ... Usually made of plastic resin, dental sealants protect teeth from bacteria that ...

  8. Effect of artificial aging on the roughness and microhardness of sealed composites.

    Science.gov (United States)

    Catelan, Anderson; Briso, André L F; Sundfeld, Renato H; Dos Santos, Paulo H

    2010-10-01

      The application of surface sealant could improve the surface quality and success of composite restorations; however, it is important to assess the behavior of this material when subjected to aging procedures.   To evaluate the effect of artificial aging on the surface roughness and microhardness of sealed microhybrids and nanofilled composites.   One hundred disc-shaped specimens were made for each composite. After 24 hours, all samples were polished and surface sealant was applied to 50 specimens of each composite. Surface roughness (Ra) was determined with a profilometer and Knoop microhardness was assessed with a 50-g load for 15 seconds. Ten specimens of each group were aged during 252 hours in a UV-accelerated aging chamber or immersed for 28 days in cola soft drink, orange juice, red wine staining solutions, or distilled water. Data were analyzed by two-way analysis of variance and Fischer's test (α=0.05).   Artificial aging decreased microhardness values for all materials, with the exceptions of Vit-l-escence (Ultradent Products Inc., South Jordan UT, USA) and Supreme XT (3M ESPE, St. Paul, MN, USA) sealed composites; surface roughness values were not altered. Water storage had less effect on microhardness, compared with the other aging processes. The sealed materials presented lower roughness and microhardness values, when compared with unsealed composites.   Aging methods decreased the microhardness values of a number of composites, with the exception of some sealed composites, but did not alter the surface roughness of the materials. The long-term maintenance of the surface quality of materials is fundamental to improving the longevity of esthetic restorations. In this manner, the use of surface sealants could be an important step in the restorative procedure using resin-based materials. © 2010, COPYRIGHT THE AUTHORS. JOURNAL COMPILATION © 2010, WILEY PERIODICALS, INC.

  9. Introduction of a potent single-donor fibrin glue for vascular anastomosis: An animal study

    Directory of Open Access Journals (Sweden)

    Mehdi Rasti Ardakani

    2012-01-01

    Full Text Available Background: Vascular anastomosis is considered as a difficult surgical procedure. Although different alternative methods have been tried to tackle these difficulties, none were found to be successful. Commercial fibrin glue has recently been used for vascular anastomosis. However, it did not gain popularity due to some limitations such as low tensile strength, rapid removal by the immune system, and risk of transmission of blood-borne viral infections. In this article, we presented a novel method for producing single-donor human fibrin glue and determined its success rate for vascular anastomosis in an animal model. Materials ans Methods : In this study, 3 mL of single-donor fibrin sealant was prepared from 150 mL of whole blood containing 50-70 mg/mL of fibrinogen. The study was performed on 10 dogs and 5 cats. After transection of the carotid artery, both ends were anastomosed by means of 3-4 sutures (Prolene 8-0. The suture line was then sealed with one layer of the new fibrin sealant. After 3-8 weeks, the site of anastomosis was evaluated angiographically and morphologically for healing and possible complications such as thrombosis or aneurysm. Results: In evaluations 3 weeks after the surgery, all arterial anastomoses were patent in dogs, but some degree of subintimal hyperplasia was noted. After 8 weeks, all anastomoses were patent and the degree of subintimal hyperplasia was decreased. In cats on the other hand, after 4 weeks, all anastomoses were patent and subintimal hyperplasia was absent. Conclusions: Single-donor fibrin glue was a quite reliable and practical alternative to minimize suturing and therefore operative time in our animal model. This sealant can easily be obtained from the patient′s whole blood. Its application in humans would require further studies.

  10. Merging weather data with materials response data during outdoor exposure

    Science.gov (United States)

    R. Sam Williams; Anand Sanadi; Corey Halpin; Christopher White

    2002-01-01

    As part of an outdoor exposure protocol for a study of sealants, a full weather station was installed at the Forest Products Laboratory field test site near Madison, Wisconsin. Tem-perature, relative humidity, rainfall, ultraviolet (UV) radiation at 18 different wavelengths, and wind speed and direction are continuously measured. Using a specially designed apparatus,...

  11. Atomic force microscopy and tridimensional topography analysis of human enamel after resinous infiltration and storage in water.

    Science.gov (United States)

    Taher, Nadia M

    2013-04-01

    To evaluate the effect of water storage on surface roughness (Ra) of human enamel after treatment with resin infiltrant and fissure sealant, by utilizing atomic force microscopy (AFM) and microtomography. This study was conducted after registration and ethical approval clarification at the College of Dentistry Research Center, King Saud University, Riyadh, Kingdom of Saudi Arabia between January 2011 and August 2011. Thirty enamel surface specimens were prepared from caries-free human premolar teeth. Specimens were divided into 3 groups: Group I, was the control; Group II, a resin infiltrant (Icon) was applied on the enamel surfaces; and Group III, the teeth were treated with fissure sealant (SealRite). All specimens were stored in distilled water for 6 months and then, subjected to AFM Veeco CP11 1.2 analysis. A few specimens were scanned by skyscan-1072-x-ray microtomography. The Ra mean readings were recorded and statistical analysis was performed with the Statistical Package for Social Sciences Version 16 at the significance level of pwater and its protective effect on enamel surface.

  12. Lamination cooling system

    Science.gov (United States)

    Rippel, Wally E.; Kobayashi, Daryl M.

    2005-10-11

    An electric motor, transformer or inductor having a lamination cooling system including a stack of laminations, each defining a plurality of apertures at least partially coincident with apertures of adjacent laminations. The apertures define a plurality of cooling-fluid passageways through the lamination stack, and gaps between the adjacent laminations are sealed to prevent a liquid cooling fluid in the passageways from escaping between the laminations. The gaps are sealed by injecting a heat-cured sealant into the passageways, expelling excess sealant, and heat-curing the lamination stack. The apertures of each lamination can be coincident with the same-sized apertures of adjacent laminations to form straight passageways, or they can vary in size, shape and/or position to form non-axial passageways, angled passageways, bidirectional passageways, and manifold sections of passageways that connect a plurality of different passageway sections. Manifold members adjoin opposite ends of the lamination stack, and each is configured with one or more cavities to act as a manifold to adjacent passageway ends. Complex manifold arrangements can create bidirectional flow in a variety of patterns.

  13. Evaluating weather factors and material response during outdoor exposure to determine accelerated test protocols for predicting service life

    Science.gov (United States)

    R. Sam Williams; Steven Lacher; Corey Halpin; Christopher White

    2005-01-01

    To develop service life prediction methods for the study of sealants, a fully instrumented weather station was installed at an outdoor test site near Madison, WI. Temperature, relative humidiy, rainfall, ultraviolet (UV) radiation at 18 wavelengths, and wind speed and direction are being continuously measured and stored. The weather data can be integrated over time to...

  14. Chemical, Biological, and Radiological (CBR) Contamination Survivability, Small Items of Equipment

    Science.gov (United States)

    2012-06-22

    contaminated with CWAs. May cause hardening or swelling of the sealant, which may weaken the seal. Rivet Stainless steel Not expected to have any effect...fallout, and nuclear survivability, which covers initial nu- clear weapon effects including Electromagnetic Pulse (EMP). Combat Developer . A...EA environmental assessment ECBC Edgewood Chemical Biological Center EMP electromagnetic pulse FD/SC Failure Definition/Scoring Criteria FM

  15. Evolution of hemostatic agents in surgical practice

    Directory of Open Access Journals (Sweden)

    Chandru P Sundaram

    2010-01-01

    Conclusions : A review of the evolution of topical hemostatic agents highlights opportunities for potential novel research. Fibrin sealants may have the most opportunity for advancement, and understanding the history of these products is useful. With the drive in urology for minimally invasive surgical techniques, adaptation of topical hemostatic agents to this surgical approach would be valuable and offers an opportunity for novel contributions.

  16. A review of the literature: the economic impact of preventive dental hygiene services.

    Science.gov (United States)

    Sharon, Stull C; Connolly, Irene M; Murphree, Kellie R

    2005-01-01

    The contributions of dental hygiene as a discipline of prevention, the inception of systemic fluoride in community water systems, the continual research conducted by the National Institute of Dental and Craniofacial Research (NIDCR), and the success of dental sealants have all contributed to the decrease in incidences of dental diseases. The prevalence of employer-based dental insurance must also be recognized as contributing to a substantial paradigm shift on the utilization of oral health preventive services. This review of the economic impact of oral health preventive services on the consumer and the private dental practice suggests that these services have had a significant impact. Dentistry's challenge remains to extend these considerable gains in oral health status to the 150 million U.S. citizens who do not have access to oral health care services identified in the 2000 Oral Health in America: A Report of the Surgeon General. Utilizing preventive, therapeutic, and educational aspects of dental hygiene services, reaching communities without fluoridation of the public water supply, and incorporating mass pediatric dental sealant programs analogous to immunization programs would improve the oral health status of underserved populations.

  17. [Use of adipose-derived stem cells in an experimental rotator cuff fracture animal model].

    Science.gov (United States)

    Barco, R; Encinas, C; Valencia, M; Carrascal, M T; García-Arranz, M; Antuña, S

    2015-01-01

    Rotator cuff repairs have shown a high level of re-ruptures. We hypothesized that the use of adipose-derived stem cells (ASC) could improve the biomechanical and histological properties of the repair. Controlled experimental study conducted on 44 BDIX rats with section and repair of the supraspinatus tendon and randomization to one of three groups: group A, no intervention (control); group B, local applications of a fibrin sealant; and group C, application of the fibrin sealant with 2 x 10(6) ASC. At 4 and 8 weeks a biomechanical and histological analysis was performed. There were no differences in load-to-failure at 4 and 8 weeks between groups. The load-to-failure did increase between week 4 and week 8. Histologically the tendon-to bone union showed a disorganized fibrovascular tissue. Group C showed a different inflammatory pattern, with less presence of neutrophils and more presence of plasma cells. The use of ASC does not improve the biomechanical or histological properties of the repair site. More studies are needed to improve techniques that enhance the healing site of the repair. Copyright © 2014 SECOT. Published by Elsevier Espana. All rights reserved.

  18. Final Environmental Assessment: Perimeter Fence Upgrade and Demolition of Two Sheds and Two Water Tanks, Lake Kickapoo Air Force Space Surveillance Station, Texas

    Science.gov (United States)

    2012-11-01

    conglomerates of the Nocona and Archer City Formations. Quaternary gravels, terrace deposits, and alluvium are present along the major drainages in the...packings, gaskets, resilient floor covering, pliable sealants and mastics and asphalt roofing products containing more than one percent asbestos...flooring and roofing materials. Less commonly used as a building material since the mid-1970s, asbestos is still in use or distribution in certain

  19. Mongolian Rotifers on Micr oscope Slides: Instructions to Permanent Specimen Mounts from Expedition Material

    OpenAIRE

    Christian D. Jersabek; Erdene Bolortsetseg; Howard L. Taylor

    2010-01-01

    We here describe a method for permanently mounting specimens on microscope slides, as we applied it in the newly established rotifer collection in Ulaanbaatar, Mongolia. The liquid photopolymer NOA 61 was used as a primary sealant for pure glycerine mounts. We furthermore outline simple methods of rotifer narcotization and fi xation in the fi eld that yield, for the majority of species, adequately preserved specimen mat...

  20. Chemical, Biological, and Radiological (CBR) Contamination Survivability: Large Item Interiors

    Science.gov (United States)

    2012-06-22

    CWAs. May cause hardening or swelling of the sealant, which may weaken the seal. Rivet Stainless steel Not expected to have any effect. Not... Electromagnetic Pulse (EMP). TOP 08-2-509 22 June 2012 A-2 APPENDIX A. EXPLANATION OF TERMS. Combat Developer. A category of sponsor...Edgewood Chemical Biological Center EMP electromagnetic pulse FD/SC Failure Definition/Scoring Criteria FM Field Manual FP fluorescent particle

  1. Platelet Concentrates: Past, Present and Future

    OpenAIRE

    Prakash, Shobha; Thakur, Aditi

    2011-01-01

    Platelets play a crucial role in hemostasis and wound healing, platelet growth factors are well known source of healing cytokines. Numerous techniques of autologous platelet concentrates have been developed and applied in oral and maxillofacial surgery. This review describes the evolution of the first and second generation of platelet concentrates (platelet rich plasma and platelet rich fibrin respectively) from their fore runner-fibrin sealants.

  2. HVAC; Heating, Ventilation, Air Conditioning - Aerosol Duct Sealant

    Science.gov (United States)

    2016-09-01

    material was applied. Annual energy and cost savings were predicted based on a typical weather year for each site. The installation of the duct...Balance reports; Visible dust streaks on duct work, ceilings near supply diffusers, or electrical boxes; Comfort complaints Specific Leakage...energy consumption , depending on the HVAC system type and the location of the ducts that were sealed. The cost effectiveness of the technology is

  3. Development of a Novel Alginate-Based Pleural Sealant

    Science.gov (United States)

    2017-09-01

    code) Standard Form 298 (Rev. 8-98) Prescribed by ANSI Std. Z39.18 19 Table of Contents Page 1. Introduction…………………………………………………………. 1 2. Keywords...lung injury model. Pig lungs obtained from a local slaughterhouse were ventilated at physiological parameters in a biosafety cabinet. A 1 cm

  4. Subsurface Endospore-Forming Bacteria Possess Bio-Sealant Properties.

    Science.gov (United States)

    Basha, Sreenivasulu; Lingamgunta, Lakshman Kumar; Kannali, Jayakumar; Gajula, Swarna Kumari; Bandikari, Ramesh; Dasari, Sreenivasulu; Dalavai, Veena; Chinthala, Paramageetham; Gundala, Prasada Babu; Kutagolla, Peera; Balaji, Vinodh Kumar

    2018-04-24

    Concrete is a strong and fairly inexpensive building substance, but has several disadvantages like cracking that allows corrosion, thus reducing its lifespan. To mitigate these complications, long-lasting microbial self-healing cement is an alternative that is eco-friendly and also actively repairs cracks. The present paper describes the detailed experimental investigation on compressive strength of cement mortars, mixed with six alkaliphilic bacteria, isolated from subsurface mica mines of high alkalinity. The experiments showed that the addition of alkaliphilic isolates at different cell concentrations (10 4 and 10 6 cells/ml) enhanced the compressive strength of cement mortar, because the rapid growth of bacteria at high alkalinity precipitates calcite crystals that lead to filling of pores and densifying the concrete mix. Thus, Bacillus subtilis (SVUNM4) showed the highest compressive strength (28.61%) of cement mortar at 10 4 cells/ml compared to those of other five alkaliphilic isolates (Brevibacillus sp., SVUNM15-22.1%; P. dendritiformis, SVUNM11-19.9%; B. methylotrophicus, SVUNM9-16%; B. licheniformis, SVUNM14-12.7% and S. maltophilia, SVUNM13-9.6%) and controlled cement mortar as well. This method resulted in the filling of cracks in concrete with calcite (CaCO 3 ), which was observed by scanning electron microscopy (SEM). Our results showed that the alkaliphilic bacterial isolates used in the study are effective in self-healing and repair of concrete cracks.

  5. Protective fibrin-sealed plication of the small bowel in recurrent laparotomy.

    Science.gov (United States)

    Holland-Cunz, S; Boelter, A V; Waag, K L

    2003-09-01

    Adhesions after recurrent abdominal operations remain extremely common and are sources of severe morbidity. Fibrin-glued plication of the small gut in a meander-like formation is supposed to guarantee a decreased risk of intestinal obstruction postoperatively. This retrospective study analyses the clinical outcome after recurrent laparotomy in children treated with bowel plication by fibrin sealant. The surgical technique of performing the fibrin-glued plication is rather simple and quick: after taking off all adhesions two to four loops of the small gut are positioned so that they lie side by side. Beginning proximal fibrin [Tissucol fibrin sealant (Baxter)] is applied between the loops; approximately 20-30 s are needed to keep the loops in position until the fibrin dries. This manoeuvre is continued until all of the small gut is fixed in one block. The gut is brought back into the abdominal cavity without loosening the loops. This fixed formation by sero-serosal adhesions or mesenterial plications is supposed to guarantee postoperative free passage. The charts of 60 children who had undergone a fibrin plication of the small bowel between 1991 and 1999 were evaluated. Additionally, questionnaires were sent to all patients, and they were invited for an examination. Sixty patients (38 boys and 22 girls) received a fibrin sealant plication because of recurrent laparotomies with heavily serosal defects or recurrent ileus because of adhesions. The youngest baby was 10 days. Since 23 patients were premature the oldest patient was 11 years old. There were no intraoperative complications attributed to the method. In the postoperative period 7/60 (12%) patients had a recurrent ileus or subileus, leading in three (5%) patients to an early relaparotomy. The fibrin-glued plication of the small bowel decreases the risk of recurrent ileus or subileus considering the high figures in the literature concerning this issue. The time-saving method is very simple and easily feasible

  6. Physical, chemical and antimicrobial evaluation of a composite material containing quaternary ammonium salt for braces cementation

    International Nuclear Information System (INIS)

    Sugii, Mari Miura; Ferreira, Fábio Augusto de Souza; Müller, Karina Cogo; Lima, Debora Alves Nunes Leite; Groppo, Francisco Carlos; Imasato, Hidetake; Rodrigues-Filho, Ubirajara Pereira

    2017-01-01

    The antibiofilm effect of iodide quaternary ammonium methacryloxy silicate (IQAMS) in Transbond XT Light Cure Adhesive resin used for braces cementation was evaluated. Fourier Transform Infrared (FTIR) spectroscopy confirmed IQAMS formation and Scanning Electron Microscopy coupled to Energy-Dispersive X-ray Spectroscopy (SEM-EDS) revealed that as coating, the quaternary ammonium groups from IQAMS were homogeneously dispersed throughout the surface. When incorporated, the composite material presented homogeneous dispersion throughout the resin. Assays with Streptococcus mutans demonstrated enhanced antibiofilm effect for the IQAMS coated resin, with much lower colony-forming units (CFU), in comparison to incorporated IQAMS. Such a difference was assigned to low availability of quaternary ammonium groups at the surface of resin when IQAMS was incorporated, hindering its antibiofilm effect. Additionally, the incorporation of IQAMS led to slight decrease in ultimate bond strength (UBS) and shear bond strength (SBS), in comparison to the neat commercial resin. Thus, the synthesized IQAMS displays great potential as antibiofilm coating or sealant to prevent oral infections in brackets during orthodontic treatment. - Highlights: • Synthesis of ORMOSIL-based material with antibiofilm activity is performed. • Antibiofilm activity of the ORMOSIL-based material on commercial available resin for braces cementation is evaluated. • Antibiofilm ORMOSIL-based coating with potential application as varnish or sealant in orthodontic appliances is presented.

  7. Physical, chemical and antimicrobial evaluation of a composite material containing quaternary ammonium salt for braces cementation

    Energy Technology Data Exchange (ETDEWEB)

    Sugii, Mari Miura [Departamento de Odontologia Restaurativa, Faculdade de Odontologia de Piracicaba – Universidade de Campinas, Piracicaba, SP 13414-903 (Brazil); Ferreira, Fábio Augusto de Souza, E-mail: ferreira.fabio.a.s@gmail.com [Grupo de Química de Materiais Híbridos e Inorgânicos, Instituto de Química de São Carlos – Universidade de São Paulo, São Carlos, SP 13563-120 (Brazil); Müller, Karina Cogo [Departamento de Ciências Fisiológicas, Área de Farmacologia, Anestesiologia e Terapeutica, Faculdade de Odontologia de Piracicaba – Universidade de Campinas, Piracicaba, SP 13414-903 (Brazil); Lima, Debora Alves Nunes Leite [Departamento de Odontologia Restaurativa, Faculdade de Odontologia de Piracicaba – Universidade de Campinas, Piracicaba, SP 13414-903 (Brazil); Groppo, Francisco Carlos [Departamento de Ciências Fisiológicas, Área de Farmacologia, Anestesiologia e Terapeutica, Faculdade de Odontologia de Piracicaba – Universidade de Campinas, Piracicaba, SP 13414-903 (Brazil); Imasato, Hidetake; Rodrigues-Filho, Ubirajara Pereira [Grupo de Química de Materiais Híbridos e Inorgânicos, Instituto de Química de São Carlos – Universidade de São Paulo, São Carlos, SP 13563-120 (Brazil); and others

    2017-04-01

    The antibiofilm effect of iodide quaternary ammonium methacryloxy silicate (IQAMS) in Transbond XT Light Cure Adhesive resin used for braces cementation was evaluated. Fourier Transform Infrared (FTIR) spectroscopy confirmed IQAMS formation and Scanning Electron Microscopy coupled to Energy-Dispersive X-ray Spectroscopy (SEM-EDS) revealed that as coating, the quaternary ammonium groups from IQAMS were homogeneously dispersed throughout the surface. When incorporated, the composite material presented homogeneous dispersion throughout the resin. Assays with Streptococcus mutans demonstrated enhanced antibiofilm effect for the IQAMS coated resin, with much lower colony-forming units (CFU), in comparison to incorporated IQAMS. Such a difference was assigned to low availability of quaternary ammonium groups at the surface of resin when IQAMS was incorporated, hindering its antibiofilm effect. Additionally, the incorporation of IQAMS led to slight decrease in ultimate bond strength (UBS) and shear bond strength (SBS), in comparison to the neat commercial resin. Thus, the synthesized IQAMS displays great potential as antibiofilm coating or sealant to prevent oral infections in brackets during orthodontic treatment. - Highlights: • Synthesis of ORMOSIL-based material with antibiofilm activity is performed. • Antibiofilm activity of the ORMOSIL-based material on commercial available resin for braces cementation is evaluated. • Antibiofilm ORMOSIL-based coating with potential application as varnish or sealant in orthodontic appliances is presented.

  8. Use of duraseal in repair of cerebrospinal fluid leaks.

    Science.gov (United States)

    Chin, Christopher J; Kus, Lukas; Rotenberg, Brian W

    2010-10-01

    The purpose of our article is to review the use of the DuraSeal Sealant System (Confluent Surgical Inc., Waltham, MA) in the repair of complex cerebrospinal fluid (CSF) leaks in endoscopic skull-base surgery. Retrospective chart review. London Health Sciences Centre. A database of endoscopic skull-base cases between 2007 and 2009 that involved CSF leakage repaired with DuraSeal was created. Demographic data and operative reports were collected and analyzed qualitatively. Recurrence of CSF leak after repair. Five cases were identified that met study criteria. In four of the five cases, the repair was successful. There were no complications related to DuraSeal use. Comparison to a subset of patients using Tisseel Fibrin Sealant (Baxter, Toronto, ON) for repair did not show a significant difference in failure rate (χ2 = 0.029, p = .858). There are a variety of techniques described to repair CSF rhinorrhea, with various studies demonstrating the advantages of using tissue glues in CSF leak repairs. We used DuraSeal in five patients to enhance graft strength and form a watertight seal. The system was effective in the majority of patients. Our study is the first to report on endoscopic endonasal repair of CSF leaks using DuraSeal.

  9. Treatment needs and predictive capacity of explanatory variables of oral disease in young athletes with an intellectual disability in Europe and Eurasia.

    Science.gov (United States)

    Fernandez, C; Descamps, I; Fabjanska, K; Kaschke, I; Marks, L

    2016-03-01

    To evaluate the oral condition and treatment needs of young athletes with intellectual disability (ID) from 53 countries of Europe and Eurasia who participated in the Special Olympics European Games held in Antwerp, October 2014. A cross- sectional study was undertaken with data collected through standardised procedures from consenting athletes under 21 years of age. Oral hygiene habits, reports of oral pain and presence of gingival signs, sealants, untreated caries and missing teeth were recorded. Data analysis was performed in SPSS to produce descriptive statistics and explanatory variables for untreated decay, and gingival signs of disease were tested with Multilevel Generalized Linear Mixed Models. Five hundred three athletes participated in this study (mean age 17 yrs). Untreated decay was recorded in 33.4% of the participants and 38.7% of them had signs of gingival disease. Absence of untreated decay was associated with lower chances of gingival signs, while absence of sealants was related with higher chances of untreated decay. There is consistent evidence of persistent need for increased promotion of oral health, as well as preventive and restorative treatment in young athletes with ID in Europe and Eurasia. Due to the limited predictive capacity of the studied variables for oral disease, further studies including other related factors are needed.

  10. Geomechanical Simulation of CO2 Leakage and Cap Rock Remediation

    Energy Technology Data Exchange (ETDEWEB)

    Nygaard, Runar [Univ. of Missouri, Rolla, MO (United States); Bai, Baojun [Univ. of Missouri, Rolla, MO (United States); Eckert, Andreas [Univ. of Missouri, Rolla, MO (United States)

    2012-09-30

    CO2 sequestration into porous and permeable brine filled aquifers is seen as one of the most likely near-term solutions for reducing greenhouse gases. Safely storing injected CO2, which is less dense than water, requires trapping the CO2 under an impermeable rock which would act as a seal. One of the concerns with CO2 sequestration is the generation of new fractures or reactivation of existing fractures and faults caused by CO2 injection into the sealing formation. Mitigation strategies must be developed to remediate potentially leaking faults or fractures. This project evaluated potential storage scenarios in the state of Missouri and developed coupled reservoir and geomechanic simulations to identify storage potential and leakage risks. Further, several injectable materials used to seal discontinuities were evaluated under subsurface conditions. The four sealant materials investigated were paraffin wax, silica based gel, polymer based gel, and micro-cement, which all significantly reduced the fracture permeability. However, the micro-cement was the most effective sealing agent and the only sealant able to withstand the large differential pressure caused by CO2 or brine injection and create a strong seal to prevent further fracturing.

  11. Presence and leaching of bisphenol a (BPA) from dental materials

    Science.gov (United States)

    Becher, Rune; Wellendorf, Hanne; Sakhi, Amrit Kaur; Samuelsen, Jan Tore; Thomsen, Cathrine; Bølling, Anette Kocbach; Kopperud, Hilde Molvig

    2018-01-01

    Abstract BPA has been reported to leach from some resin based dental restorative materials and materials used for orthodontic treatment. To confirm and update previous findings, especially in light of the new temporary lower threshold value for tolerable daily BPA intake, we have investigated the leaching of BPA from 4 composite filling materials, 3 sealants and 2 orthodontic bonding materials. The materials were either uncured and dissolved in methanol or cured. The cured materials were kept in deionized water for 24 hours or 2 weeks. Samples were subsequently analyzed by ultra-performance liquid chromatography coupled to mass spectrometry (UPLC-MS-MS). The composite filling material Tetric EvoFlow® and the fissure sealant DELTON® showed significantly higher levels of BPA leaching compared to control samples for all test conditions (uncured, 24 h leaching and 2 weeks leaching). There were no significant differences in amount of leached BPA for any of the tested materials after 24 hours compared to 2 weeks. These results show that BPA is still released from some dental materials despite the general concern about potential adverse effects of BPA. However, the amounts of BPA were relatively low and most likely represent a very small contribution to the total BPA exposure. PMID:29868625

  12. Glass/Ceramic Composites for Sealing Solid Oxide Fuel Cells

    Science.gov (United States)

    Bansal, Narottam P.; Choi, Sung R.

    2007-01-01

    A family of glass/ceramic composite materials has been investigated for use as sealants in planar solid oxide fuel cells. These materials are modified versions of a barium calcium aluminosilicate glass developed previously for the same purpose. The composition of the glass in mole percentages is 35BaO + 15CaO + 5Al2O3 + 10B2O3 + 35SiO2. The glass seal was found to be susceptible to cracking during thermal cycling of the fuel cells. The goal in formulating the glass/ ceramic composite materials was to (1) retain the physical and chemical advantages that led to the prior selection of the barium calcium aluminosilicate glass as the sealant while (2) increasing strength and fracture toughness so as to reduce the tendency toward cracking. Each of the composite formulations consists of the glass plus either of two ceramic reinforcements in a proportion between 0 and 30 mole percent. One of the ceramic reinforcements consists of alumina platelets; the other one consists of particles of yttria-stabilized zirconia wherein the yttria content is 3 mole percent (3YSZ). In preparation for experiments, panels of the glass/ceramic composites were hot-pressed and machined into test bars.

  13. In vivo near infrared (NIRS) sensor attachment using fibrin bioadhesive

    Science.gov (United States)

    Macnab, Andrew; Pagano, Roberto; Kwon, Brian; Dumont, Guy; Shadgan, Babak

    2018-02-01

    Background: `Tisseel' (Baxter Healthcare, Deerfield, IL) is a fibrin-based sealant that is commonly used during spine surgery to augment dural repairs. We wish to intra-operatively secure a near infrared spectroscopy (NIRS) sensor to the dura in order to monitor the tissue hemodynamics of the underlying spinal cord. To determine if `Tisseel' sealant adversely attenuates NIR photon transmission. Methods: We investigated `Tisseel' in both an in vitro and in vivo paradigm. For in vitro testing, we used a 1 mm pathlength cuvette containing either air or `Tisseel' interposed between a NIR light source (760 and 850 nm) and a photodiode detector and compared transmittance. For in vivo testing, a continuous wave (760 and 850 nm) spatiallyresolved NIRS device was placed over the triceps muscle using either conventional skin apposition (overlying adhesive bandage) or bioadhesion with `Tisseel'. Raw optical data and tissue saturation index (TSI%) collected at rest were compared. Results: In-vitro NIR light absorption by `Tisseel' was very high, with transmittance reduced by 95% compared to air. In-vivo muscle TSI% values were 80% with conventional attachment and 20% using fibrin glue. Conclusion: The optical properties of `Tisseel' significantly attenuate NIR light during in-vitro transmittance and critically compromise photon transmission in-vivo.

  14. Rehabilitation of Permeable Breakwaters and Jetties by Void Sealing: Summary Report. Repair, Evaluation, Maintenance, and Rehabilitation Research Program

    Science.gov (United States)

    1990-10-01

    able sealing material that has promising characteristics for coastal engineer- ing applications. Microfine Cement, a company which markets ultrafine...cement, claims the product can penetrate fine sand and is strong and durable with a 4- to 5-hr set tine. Fifty percent of Microfine Cement’s...sealant. The casing can be pierced at any selected point by firing an explosive-impelled projectile from a device lowered into the casing. d. Tubes A

  15. IVO develops a new repair technique for underwater sites. Viscous doughlike substance underwater cracks

    Energy Technology Data Exchange (ETDEWEB)

    Klingstedt, G.; Leisio, C. [ed.

    1998-07-01

    A viscous sealant is revolutionizing repair of the stone and concrete masonry of underwater dams, bridges and canals. There is now no need for expensive and time-consuming cofferdams, since a diver can extrude quick-setting mortar into underwater structures needing repair. This technique has worked well in recent years in various parts of Finland even in strongly flowing water. IVO experts are now starting to look more beyond the borders of Finland

  16. Efficacy of Laser Fluorescence in Dental Caries Diagnosis: A Meta-Analysis

    Science.gov (United States)

    2012-06-01

    detecting secondary caries around amalgam restorations. Diniz and colleagues (53) examined the influence of clear and opaque sealants on laser...Int Dent J 1997; 47(5): 259-265. 36. De Paula A, Campos J, Diniz M, Hebling J, Rodrigues J. In situ and in vitro comparison of laser fluorescence...DIAGNOdent in the detection of secondary carious lesions. Acta Odont Scandinavia, 2005; 63: 26-30. 53. Diniz M, Rodrigues J, Hug I, Cordeiro R, Lussi

  17. The Australian Disaster Rescue Manual. Second Edition

    Science.gov (United States)

    1988-01-01

    manufacture, wires and strands are either coated with lubricant to prevent corrosion and friction in the rope, or are galvanised. The size of Steel Wire...have an adverse affect on steel. Periodical inspection for corrosion is necessary. - 25 2.18 Records The results of all inspection, including details of...small holes 4n fibro, iron, alluminium can be repaired with greater speed using a sealant. Mineral fibre reinforced asphaltic sealing compounds such

  18. Polymer-cement interactions towards improved wellbore cement fracture sealants

    Science.gov (United States)

    Beckingham, B. S.; Iloejesi, C.; Minkler, M. J.; Schindler, A. K.; Beckingham, L. E.

    2017-12-01

    Carbon capture, utilization, and storage (CCUS) in deep geologic formations is a promising means of reducing point source emissions of CO2. In these systems, CO2 is captured at the source and then injected to be utilized (eg. in enhanced oil recovery or as a working fluid in enhanced geothermal energy plants) or stored in geologic formations such as depleted oil and gas reservoirs or saline aquifers. While CCUS in subsurface systems could aid in reducing atmospheric CO2 emissions, the potential for CO2 leakage from these systems to overlying formations remains a major limitation and poses a significant risk to the security of injected CO2. Thus, improved materials for both initial wellbore isolation and repairing leakage pathways that develop over time are sought. One approach for the repair of cement fractures in wellbore (and other) systems is the injection of polymer materials into the fracture with a subsequent environmentally dependent (temperature, pressure, pH, etc.) densification or solidification. Here, we aim to investigate novel polymer materials for use to repair leaking wellbores in the context of CCUS. We synthesize and fully characterize a series of novel polymer materials and utilize a suite of analysis techniques to examine polymer-cement interactions at a range of conditions (namely temperature, pressure and pH). Initial findings will be leveraged to design novel polymer materials for further evaluation in polymer-cement composite cores, cement fracture healing, and the aging behavior of healed cements.

  19. Development and evaluation of radon sealants for uranium mines

    International Nuclear Information System (INIS)

    Hammon, H.G.; Ernst, K.; Gaskill, J.R.; Newton, J.C.; Morris, C.J.

    1975-01-01

    Coatings for use as radon barriers were evaluated. Coating materials evaluated included epoxy resins, furfuryl alcohol polymers, styrenated polyesters, polyvinyl acetate, and acrylic emulsions. It was calculated that virtually all coatings with permeation constants lower than 10 -10 cm 3 /sub STP/ . cm/s . cm 2 .cm Hg and thicknesses between 5 and 10 mil will provide nearly 100 percent effectiveness. The selection of a suitable coating then ought to be based on other factors such as cost/m 2 , vapor toxicity during application, ability to bind to the uranium ore in continuous films free of pin-holes etc. Obviously, any openings in the mine shafts and tunnels which are not covered with a film or any discontinuities of the film will act like the spillway on a water dam, i.e., the radon contained behind the barrier will flow out into the tunnel. (U.S.)

  20. Determination of Short-Chain Chlorinated Paraffins by Carbon Skeleton Gas Chromatography

    OpenAIRE

    PELLIZZATO FRANCESCA; RICCI MARINA; HELD ANDREA; EMONS HENDRIK

    2008-01-01

    Short-Chain Chlorinated Paraffins (SCCPs) are highly complex technical mixtures of polychlorinated n-alkanes with a chlorination degree between 50 and 70 % by mass, and a linear carbon chain length from C10 to C13, constituted by thousands of homologues, diastereomers and enantiomers. They have been used in many different applications, such as extreme pressure additives in lubricants and cutting fluids, plasticizers in PVC, and flame retardants in paints, adhesives and sealants. SCCPs are tox...

  1. The characterisation of Manganese (IV) compounds and the study of the thermal decomposition of Potassium Chlorate alone and with Mn(IV) and other oxides and salts

    OpenAIRE

    Goldblatt, Nicholas Zalmon

    1998-01-01

    This thesis was submitted for the degree of Doctor of Philosophy and awarded by Brunel University. Manganese dioxide compounds are preferred curing agents for Polysulphide resins used as sealants in industry. These are required to have consistent setting characteristics and the investigation was initiated to characterise a number of proffered compounds of this type an to establish criteria by which an informed choice could be made of an optimum curing ages for a specific set of conditio...

  2. Development of a new bonding material and its trial application to accelerator technology

    International Nuclear Information System (INIS)

    Tanaka, Yasuhito; Yamano, Kiyoshi; Saito, Kenji

    2001-01-01

    We have succeeded to develop a new bonding material for new television technology, which has a very low outgas property. This bonding material has been tested and confirmed the excellent sealing or outgas property in various institutes. We have tried it to use as a vacuum sealant against the super-leaking in He-II. In this report, we will present the motivation of the bonding material development, and the result of the application to cryogenics. (author)

  3. Disparities in children's oral health and access to dental care.

    Science.gov (United States)

    Mouradian, W E; Wehr, E; Crall, J J

    Dental caries can be prevented by a combination of community, professional, and individual measures including water fluoridation, professionally applied topical fluorides and dental sealants, and use of fluoride toothpastes. Yet, tooth decay is the most common chronic disease of childhood. Dental care is the most prevalent unmet health need in US children with wide disparities existing in oral health and access to care. Only 1 in 5 children covered by Medicaid received preventive oral care for which they are eligible. Children from low income and minority families have poorer oral health outcomes, fewer dental visits, and fewer protective sealants. Water fluoridation is the most effective measure in preventing caries, but only 62% of water supplies are fluoridated, and lack of fluoridation may disproportionately affect poor and minority children. Childhood oral disease has significant medical and financial consequences that may not be appreciated because of the separation of medicine and dentistry. The infectious nature of dental caries, its early onset, and the potential of early interventions require an emphasis on preventive oral care in primary pediatric care to complement existing dental services. However, many pediatricians lack critical knowledge to promote oral health. We recommend financial incentives for prioritizing Medicaid Early and Periodic Screening, Diagnostic, and Treatment dental services; managed care accountability; integration of medical and dental professional training, clinical care, and research; and national leadership. JAMA. 2000;284:2625-2631.

  4. Technical aspects of pancreaticoduodenectomy and their outcomes.

    Science.gov (United States)

    Giuliano, Katherine; Ejaz, Aslam; He, Jin

    2017-12-01

    Pancreatic cancer is the fourth leading cause of cancer-related death in the Unites States and is rising in incidence. For the 15-25% of patients who do not have either metastatic or locally advanced disease, surgical resection with pancreaticoduodenectomy is the standard of care and results in improved 5-year survival of 15-25%. While mortality at high-volume centers is less than 5%, morbidity remains high at approximately 30-45%. This paper reviews technical aspects of pancreaticoduodenectomy and their outcomes. Specifically, we review technique and the outcome literature on vascular reconstruction, attempts to decrease delayed gastric emptying (DGE), including pylorus-preserving versus classic pancreaticoduodenectomy and gastrojejunostomy (GJ) technique, as well as attempts to decrease the rate of pancreatic fistula, including the use of pancreatic stents, fibrin sealant, and pancreaticojejunostomy (PJ) technique. Vascular resection and reconstruction have been associated with increased morbidity and mortality. However, the literature suggests that if it allows for an R0 resection, the survival is improved with comparable complication rates. DGE, one of the most common post-pancreaticoduodenectomy complications, has not been reliably decreased with various technical modifications of the GJ. The incidence of pancreatic fistula, one of the most morbid postoperative complications, is not definitively reduced by either the use of pancreatic stents or fibrin sealant. Additional research is needed to determine methods to further decrease rates of morbidity.

  5. MEASUREMENTS OF THE CONFINEMENT LEAKTIGHTNESS AT THE KOLA NUCLEAR POWER STATION (UNIT 2) IN RUSSIA

    International Nuclear Information System (INIS)

    GREENE, G.A.; GUPPY, J.G.

    1998-01-01

    This is the final report on the INSP project entitled, ''Kola Confinement Leaktightness'' conducted by BNL under the authorization of Project Work Plan WBS 1.2.2.1. This project was initiated in February 1993 to assist the Russians to reduce risks associated with the continued operation of older Soviet-designed nuclear power plants, specifically the Kola VVER-440/230 Units 1 and 2, through upgrades in the confinement performance to reduce the uncontrolled leakage rate. The major technical objective of this-project was to improve the leaktightness of the Kola NPP VVER confinement boundaries, through the application of a variety of sealants to penetrations, doors and hatches, seams and surfaces, to the extent that current technology permitted. A related objective was the transfer, through training of Russian staff, of the materials application procedures to the staff of the Kola NPP. This project was part of an overall approach to minimizing uncontrolled releases from the Kola NPP VVER440/230s in the event of a serious accident, and to thereby significantly mitigate the consequences of such an accident. The US provided materials, application technology, and applications equipment for application of sealant materials, surface coatings, potting materials and gaskets, to improve the confinement leaktightness of the Kola VVER-440/23Os. The US provided for training of Russian personnel in the applications technology

  6. Substance Flow Analyses of Organic Pollutants in Stockholm

    International Nuclear Information System (INIS)

    Jonsson, A.; Friden, U.; Thuresson, K.; Soerme, L.

    2008-01-01

    This paper summarizes substance flow analyses for four organic substances in the City of Stockholm, Sweden: diethylhexyl phthalate (DEHP), alkylphenolethoxylates (APEO), polybrominated diphenylethers (PBDE) and chlorinated paraffins (CP). The results indicate that the stocks of APEO, PBDE and CP all are approximately 200-250 tonnes, whereas the DEHP stock is two orders of magnitude larger. Emissions can be linked to imported consumer goods such as electronics (PBDE) and textiles (APEO), and to construction materials (DEHP, CP). For several of the substances considerable amounts remain in the technosphere for a long time, even after use of the substance in new products has been eliminated. For example, the use of DEHP as plasticizer for PVC plastics in cables and floorings has more or less been phased-out, but still these applications make up a stock of some 20,000 tonnes (85% of the total DEHP stock in Stockholm) and emit 28 tonnes of DEHP annually (93% of overall emissions). Likewise, the use of chlorinated paraffins in sealants has been radically reduced, but there are 170 tonnes of CP in sealants in Stockholm making up 75% of the stock, and causing half of the emissions to water and air. These emissions are likely to continue for decades, and the stocks therefore have to be considered when analysing and managing the impact of urban substance flows on the environment

  7. Evaluation of a novel approach in the prevention of white spot lesions around orthodontic brackets.

    Science.gov (United States)

    Yap, J; Walsh, L J; Naser-Ud Din, S; Ngo, H; Manton, D J

    2014-03-01

    The purpose of this study was to evaluate and compare the relative efficacy of a resin fissure sealant, nano-filled self-adhesive protective coating, resin infiltrant, glass ionomer cement (GIC), and GIC containing casein phosphopeptide-amorphous calcium phosphate (CPP-ACP) in preventing the formation of subsurface lesions of enamel (SLE) adjacent to orthodontic brackets by acting as an enamel surface sealant (ESS). Eighty-five enamel specimens with molar tubes bonded at their centre were randomly divided into five groups, each treated with a different material at the bracket's periphery. Specimens were stored in an acetate demineralization solution at pH 4.5 for 7 days at 37 °C then imaged using quantitative light-induced fluorescence (QLF) to determine the difference in fluorescence (∆F) between sound- and acid-exposed enamel. Lesion cross-sections were then examined using backscattered scanning electron microscopy (SEM) to measure lesion depth. The use of GIC alone or incorporating CPP-ACP significantly reduced ∆F compared with other materials. Backscattered SEM images showed no measurable demineralization for enamel treated with either GIC material in contrast with other groups, which showed statistically significant demineralization levels. The fluoride-releasing effects and CPP-ACP benefits of the GIC materials show promise as an effective ESS in inhibiting enamel demineralization adjacent to orthodontic brackets. © 2014 Australian Dental Association.

  8. MEASUREMENTS OF THE CONFINEMENT LEAKTIGHTNESS AT THE KOLA NUCLEAR POWER STATION (UNIT 2) IN RUSSIA

    Energy Technology Data Exchange (ETDEWEB)

    GREENE,G.A.; GUPPY,J.G.

    1998-08-01

    This is the final report on the INSP project entitled, ``Kola Confinement Leaktightness'' conducted by BNL under the authorization of Project Work Plan WBS 1.2.2.1. This project was initiated in February 1993 to assist the Russians to reduce risks associated with the continued operation of older Soviet-designed nuclear power plants, specifically the Kola VVER-440/230 Units 1 and 2, through upgrades in the confinement performance to reduce the uncontrolled leakage rate. The major technical objective of this-project was to improve the leaktightness of the Kola NPP VVER confinement boundaries, through the application of a variety of sealants to penetrations, doors and hatches, seams and surfaces, to the extent that current technology permitted. A related objective was the transfer, through training of Russian staff, of the materials application procedures to the staff of the Kola NPP. This project was part of an overall approach to minimizing uncontrolled releases from the Kola NPP VVER440/230s in the event of a serious accident, and to thereby significantly mitigate the consequences of such an accident. The US provided materials, application technology, and applications equipment for application of sealant materials, surface coatings, potting materials and gaskets, to improve the confinement leaktightness of the Kola VVER-440/23Os. The US provided for training of Russian personnel in the applications technology.

  9. Failure Rate of Pediatric Dental Treatment under General Anesthesia

    Directory of Open Access Journals (Sweden)

    Effat Khodadadi

    2018-06-01

    Full Text Available Aim: To assess the failure rates of various pediatric dental treatments performed under general anesthesia (GA after six months to five years of follow-up. Design: This multicenter retrospective cohort study was performed on patients treated by five pedodontists in two private hospitals located in northern Iran during 2010–2013 and comprised 155 patients. The patients were recalled and clinically examined. During the clinical examination of the primary teeth, oral hygiene, dmft index, and failure of previous treatments was evaluated. The data were analyzed using the Chi square and regression analyses with a significance level of 0.05. Results: 114 patients (74 males and 40 females, mean age: 37.17 ± 10.75 months with 1155 primary teeth treated under GA participated in the follow-up. The overall failure rate was 6.59%. The failure rates of pulpectomy, pulopotomy, fissure sealant, stainless steel crown (SSC, amalgam, and composite fillings were 2.90%, 3.03%, 4.83%, 5.26%, 5.33%, and 9.63%, respectively. Among the confounding factors, only gender had a significant effect on the anterior composite failure rate (p = 0.029 and age had a significant effect on the failure rate of fissure sealant therapy (p = 0.015 and SSC (p = 0.018. Conclusion: The overall rate of treatment failure in pediatric patients, treated under GA, was 6.59%.

  10. Human Kunitz-type protease inhibitor engineered for enhanced matrix retention extends longevity of fibrin biomaterials.

    Science.gov (United States)

    Briquez, Priscilla S; Lorentz, Kristen M; Larsson, Hans M; Frey, Peter; Hubbell, Jeffrey A

    2017-08-01

    Aprotinin is a broad-spectrum serine protease inhibitor used in the clinic as an anti-fibrinolytic agent in fibrin-based tissue sealants. However, upon re-exposure, some patients suffer from hypersensitivity immune reactions likely related to the bovine origin of aprotinin. Here, we aimed to develop a human-derived substitute to aprotinin. Based on sequence homology analyses, we identified the Kunitz-type protease inhibitor (KPI) domain of human amyloid-β A4 precursor protein as being a potential candidate. While KPI has a lower intrinsic anti-fibrinolytic activity than aprotinin, we reasoned that its efficacy is additionally limited by its fast release from fibrin material, just as aprotinin's is. Thus, we engineered KPI variants for controlled retention in fibrin biomaterials, using either covalent binding through incorporation of a substrate for the coagulation transglutaminase Factor XIIIa or through engineering of extracellular matrix protein super-affinity domains for sequestration into fibrin. We showed that both engineered KPI variants significantly slowed plasmin-mediated fibrinolysis in vitro, outperforming aprotinin. In vivo, our best engineered KPI variant (incorporating the transglutaminase substrate) extended fibrin matrix longevity by 50%, at a dose at which aprotinin did not show efficacy, thus qualifying it as a competitive substitute of aprotinin in fibrin sealants. Copyright © 2017 The Author(s). Published by Elsevier Ltd.. All rights reserved.

  11. History of electric power technological innovation in 2017

    International Nuclear Information System (INIS)

    Yamaguchi, Hiroshi; Okabe, Kazuhiko; Ichimura, Yasunori

    2017-01-01

    This is an overview of the electric power technology innovation of 12 electric power companies in 2016. Among them, this paper outlines the technological contents related to nuclear power of three major companies. TEPCO group applied a sealant from the outside to the back-up seal of reactor containment vessel that had deteriorated. It developed a good sealing system by combining with an improved sealant, and confirmed the effect at an experimental level. Regarding environmental restoration in Fukushima, TEPCO developed a personal dosimetry technology, environmental monitoring technology, and a technology to simulate radiation reduction amount after decontamination. Chubu Electric Power Company conducted researches on the applicability of the start-up range neutron monitor count rate prediction method related to fuel loading after a long-term shut-down of nuclear power generation, basic examination for practical use of laser decontamination, and possibility of tsunami prediction using satellite positioning information. With regard to the decommissioning measures of nuclear power plants, Japan Nuclear Power Electric Generation Co., Ltd. conducted studies on the decommissioning work of the Tokai Power Station, the safe dismantling method of the Tsuruga Power Station Unit 1 as decommissioning measures and fuel management, and the disposal method of radioactive contaminants. In the development of future reactor, this company conducted research on the development of fast breeder reactor system, etc. (A.O.)

  12. Indoor radon pollution: Control and mitigation. June 1978-December 1989 (Citations from the NTIS data base). Report for June 1978-December 1989

    International Nuclear Information System (INIS)

    1990-01-01

    This bibliography contains citations concerning the control and mitigation of radon pollution in homes and commercial buildings. Citations cover radon transport studies in buildings and soils, remedial action proposals on contaminated buildings, soil venting, building ventilation, sealants, filtration systems, water degassing, reduction of radon sources in building materials, and evaluation of existing radon mitigation programs including their cost effectiveness. Analysis and detection of radon and radon toxicity are covered in separate published bibliographies. (Contains 129 citations fully indexed and including a title list.)

  13. Measurement of Surface Strains from a Composite Hydrofoil using Fibre Bragg Grating Sensing Arrays

    Science.gov (United States)

    2015-07-01

    the tape is pressed into the channels using a narrow Teflon spatula. After all the film adhesive strips have been laid up in the channels a thin...roll of vacuum sealant tape was placed along the end of each channel extending across the channel walls and pressed down into the channels as shown...custom built load controlled servo -hydraulic fatigue rig. A schematic drawing of the rig is shown in Figure 14. The foil was gripped at its root end by

  14. Decision tree analysis to evaluate dry cow strategies under UK conditions

    OpenAIRE

    Berry, E.A.; Hogeveen, H.; Hillerton, J.E.

    2005-01-01

    Economic decisions on animal health strategies address the cost-benefit aspect along with animal welfare and public health concerns. Decision tree analysis at an individual cow level highlighted that there is little economic difference between the use of either dry cow antibiotic or an internal teat sealant in preventing a new intramammary infection in a cow free of infection in all quarters of the mammary gland at drying off. However, a potential net loss of over pound20 per cow might occur ...

  15. Workshop on Avionics Corrosion Control: Meeting of the Structures and Materials Panel of AGARD (62nd) Held in Hovik (Norway) on 16-17 April 1986.

    Science.gov (United States)

    1987-09-01

    operator not smoke in the recording area and that the heads not be cleaned with a halogenated cleaning solvent. Use an alcohol . J. Connector 1. Radar...frplaed a drop of sealant is placed in the area where wott is accmplshe. RTN’- 118 has been replaed with dlear RTV-3 140 which is a dlear alcohol cure...to isolate 7-6 3.3.1.1 Alumimue Effects of corrosion on aluminum runs ae open circuits caused by oxydes . The mechanism Is simple : chloride Ions make

  16. Investigations of glass sealing and reactive air brazing materials for joining high temperature solid oxide fuel cells by dilatometric examinations; Anwendung dilatometrischer Messungen bei der Entwicklung von Glasloten und reaktiven Metallloten zum Fuegen von Hochtemperaturbrennstoffzellen

    Energy Technology Data Exchange (ETDEWEB)

    Reichle, M.S. [Parker Hannifin GmbH, Bietigheim-Bissingen (Germany); Federmann, D. [Forschungszentrum Juelich GmbH, ZAT, Juelich (Germany); Reisgen, U. [RWTH Aachen University, ISF, Aachen (Germany); Koppitz, T.

    2011-03-15

    The principle of operation of solid oxide fuel cells (SOFCs) is very simple. However, the fact that very different materials are used for the individual components requires advanced thermal joining techniques to join them in a functional manner. Two very distinct designs have established themselves for the two different intended applications: decentralised power generation (stationary SOFCs) on the one hand, and power converters for vehicles (mobile SOFCs) on the other hand. As a consequence, alternative techniques for joining the individual components are also required. The principal joining process for the stationary SOFC design consists of joining individual steel plates with a glass sealant in an electrically insulating way so that they form an SOFC stack. For the mobile fuel cell design, the SOFC stack consists of individual thin steel cassettes. The window frame of the cassettes, which is made of ferritic chromium steel, is brazed to the ceramic layer of the zirconium oxide solid electrolyte using a filler metal. The material used is a silver-based brazing filler metal which contains only small amounts of copper oxide (CuO) and titanium hydride (TiH{sub 2}) as wetting agents. Both joining processes must be applicable in normal atmospheric air, i. e. under oxidative conditions. R and D activities continue for improving the efficiency and long-term operational stability of the technology to such an extent that SOFCs will become ready for the energy sector market. The two joining techniques described cannot yet be considered standard processes. They, too, will require continuous improvement with respect to reproducibility, endurance and strength of the joints. The Special Joining Techniques working group at Forschungszentrum Juelich uses specially modified dilatometric techniques as suitable quick replacement methods for studying and measuring the joining characteristics of the materials without having to manufacture complex and expensive SOFC stacks. The

  17. Nerve regeneration using tubular scaffolds from biodegradable polyurethane.

    Science.gov (United States)

    Hausner, T; Schmidhammer, R; Zandieh, S; Hopf, R; Schultz, A; Gogolewski, S; Hertz, H; Redl, H

    2007-01-01

    In severe nerve lesion, nerve defects and in brachial plexus reconstruction, autologous nerve grafting is the golden standard. Although, nerve grafting technique is the best available approach a major disadvantages exists: there is a limited source of autologous nerve grafts. This study presents data on the use of tubular scaffolds with uniaxial pore orientation from experimental biodegradable polyurethanes coated with fibrin sealant to regenerate a 8 mm resected segment of rat sciatic nerve. Tubular scaffolds: prepared by extrusion of the polymer solution in DMF into water coagulation bath. The polymer used for the preparation of tubular scaffolds was a biodegradable polyurethane based on hexamethylene diisocyanate, poly(epsilon-caprolactone) and dianhydro-D-sorbitol. EXPERIMENTAL MODEL: Eighteen Sprague Dawley rats underwent mid-thigh sciatic nerve transection and were randomly assigned to two experimental groups with immediate repair: (1) tubular scaffold, (2) 180 degrees rotated sciatic nerve segment (control). Serial functional measurements (toe spread test, placing tests) were performed weekly from 3rd to 12th week after nerve repair. On week 12, electrophysiological assessment was performed. Sciatic nerve and scaffold/nerve grafts were harvested for histomorphometric analysis. Collagenic connective tissue, Schwann cells and axons were evaluated in the proximal nerve stump, the scaffold/nerve graft and the distal nerve stump. The implants have uniaxially-oriented pore structure with a pore size in the range of 2 micorm (the pore wall) and 75 x 700 microm (elongated pores in the implant lumen). The skin of the tubular implants was nonporous. Animals which underwent repair with tubular scaffolds of biodegradable polyurethanes coated with diluted fibrin sealant had no significant functional differences compared with the nerve graft group. Control group resulted in a trend-wise better electrophysiological recovery but did not show statistically significant

  18. Efficacy of an internal teat seal associated with a dry cow intramammary antibiotic for prevention of intramammary infections in dairy cows during the dry and early lactation periods

    Directory of Open Access Journals (Sweden)

    Lívio R. Molina

    Full Text Available ABSTRACT: The present study aimed to evaluate the use of an internal dry period teat seal containing bismuth subnitrate (Teatseal®, Zoetis®, Florham Park, Nova Jersey, USA associated with a long-acting cloxacilin preparation (Orbenin® Extra dry cow, Zoetis®, Florham Park, Nova Jersey, USA, in preventing new infections during the dry-off and early postpartum period. A total of 150 Holstein cows (average production of 9,000 kg of milk per lactation, with four functional udder quarters without clinical mastitis was included in the study. All animals were dried-off 60 days before the expected calving date. Two teats positioned diagonal-contralaterally received only dry cow antibiotic, control group C (n=300 and the other two teats, treatment group T (n=300 received dry cow antibiotic and infusion with an internal teat seal. Data from SCC variable were transformed by log base-10 transformation. Duncan’s test was used accepting 5% as the level of statistical significance. The occurrence of intramammary infection (IMI and chronicity rate, and frequency of microorganisms isolated at drying and immediately postpartum in teats of group C and group T were evaluated using a non-parametric Chi-square Test, accepting 10% as the statistical significance level. There was a decrease in the occurrence of new infections in the early postpartum in cows which the sealant was used (C=19.6%, T=11.4%. In the postpartum period, Gram-negative bacteria were isolated from 16 teats in C and seven in T. The greatest reduction was observed for Escherichia coli (8 vs 1 in group T. There was no effect using the internal sealant on the frequency of isolation of environmental Streptococus. The use of sealant reduced the prevalence of subclinical mastitis cows between drying-off and the early postpartum period (C=51% versus T=42% and resulted in a lower somatic cell count (SCC in the treatment group when compared with the control group (T=1,073x103, C=1,793x103. The use of

  19. The cost-effectiveness of three interventions for providing preventive services to low-income children.

    Science.gov (United States)

    Johnson, Ben; Serban, Nicoleta; Griffin, Paul M; Tomar, Scott L

    2017-12-01

    We evaluated the impact of loan repayment programmes, revising Medicaid fee-for-service rates, and changing dental hygienist supervision requirements on access to preventive dental care for children in Georgia. We estimated cost savings from the three interventions of preventive care for young children after netting out the intervention cost. We used a regression model to evaluate the impact of changing the Medicaid reimbursement rates. The impact of supervision was evaluated by comparing general and direct supervision in school-based dental sealant programmes. Federal loan repayments to dentists and school-based sealant programmes (SBSPs) had lower intervention costs (with higher potential cost savings) than raising the Medicaid reimbursement rate. General supervision had costs 56% lower than direct supervision of dental hygienists for implementing a SBSP. Raising the Medicaid reimbursement rate by 10 percentage points would improve utilization by Loan repayment could serve almost 13 000 children for a cost of $400 000 and a potential cost saving of $176 000. The three interventions all improved met need for preventive dental care. Raising the reimbursement rate alone would marginally affect utilization of Medicaid services but would not substantially increase acceptance of Medicaid by providers. Both loan repayment programmes and amending supervision requirements are potentially cost-saving interventions. Loan repayment programmes provide complete care to targeted areas, while amending supervision requirements of dental hygienists could provide preventive care across the state. © 2017 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  20. Predictors of dental rehabilitation in children aged 3-12 years.

    Science.gov (United States)

    Gopinath, Vellore Kannan; Awad, Manal A

    2015-01-01

    The aim of this study was to evaluate the proportion of completed treatments and to study the factors affecting the full mouth dental rehabilitation in pediatric patients treated by undergraduate students at the College of Dental Medicine Teaching Clinics, University of Sharjah. A retrospective study was conducted on 270 children aged less than 12 years (mean age 7.6, SD 2.04). Comprehensive dental rehabilitation reports of child patients that were completed by final year dental undergraduate students from the year 2009 to 2011 were reviewed. Data on complete history, oral examination, dental charting, and treatment plan were collected from pediatric dentistry case sheet. Dental caries was charted using WHO 1997 criteria. Dental treatment needs and completion of dental care delivered to children involved in this study were assessed using DMFT/deft scores. Percentages of treatment provided included completed restorations (94%) and space management (84%) in primary dentition, whereas 98% of restoration and 94% of required sealants were completed in permanent dentition. The percentage of completed dental treatment including sealant placement was 61%. Age of the child and the number of decayed teeth present before the start of the treatment significantly correlated with the children in the incomplete treatment category (P dental care was provided in a holistic approach to the children attending College of Dental Medicine training clinics. Age of the child and the number of decayed teeth were the factors affecting dental rehabilitation in children aged 3-12 years.

  1. Transient Heating and Thermomechanical Stress Modeling of Ceramic HEPA Filters

    Energy Technology Data Exchange (ETDEWEB)

    Bogle, Brandon [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Kelly, James [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Haslam, Jeffrey [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States)

    2017-09-29

    The purpose of this report is to showcase an initial finite-element analysis model of a ceramic High-Efficiency Particulate (HEPA) Air filter design. Next generation HEPA filter assemblies are being developed at LLNL to withstand high-temperature fire scenarios by use of ceramics and advanced materials. The filters are meant for use in radiological and nuclear facilities, and are required to survive 500°C fires over an hour duration. During such conditions, however, collecting data under varying parameters can be challenging; therefore, a Finite Element Analysis model of the filter was conducted using COMSOL ® Multiphysics to analyze the effects of fire. Finite Element Analysis (FEA) modelling offers several opportunities: researchers can quickly and easily consider impacts of potential design changes, material selection, and flow characterization on filter performance. Specifically, this model provides stress references for the sealant at high temperatures. Modeling of full filter assemblies was deemed inefficient given the computational requirements, so a section of three tubes from the assembly was modeled. The model looked at the transient heating and thermomechanical stress development during a 500°C air flow at 6 CFM. Significant stresses were found at the ceramic-metal interfaces of the filter, and conservative temperature profiles at locations of interest were plotted. The model can be used for the development of sealants that minimize stresses at the ceramic-metal interface. Further work on the model would include the full filter assembly and consider heat losses to make more accurate predictions.

  2. Public health dental hygiene: an option for improved quality of care and quality of life.

    Science.gov (United States)

    Olmsted, Jodi L; Rublee, Nancy; Zurkawski, Emily; Kleber, Laura

    2013-10-01

    The purpose of this research was to document quality of life (QoL) and quality of care (QoC) measures for families receiving care from dental hygienists within public health departments, and to consider if oral health for families with economic disparities and cultural differences was improved. A descriptive research study using a retrospective record review was conducted considering QoC. A review of state epid "Do preventive oral health programs based in local health departments provide quality care services, thus impacting QoL for underserved populations?" A dental hygienist working in public health made significant contributions to improving access to care and QoL in a rural, socioeconomically disadvantaged community. A total of 2,364 children received education, 1,745 received oral screenings and 1,511 received dental sealants. Of these, 804 children with caries were referred, with 463 receiving restorations and follow-up care. QoL metrics basis assessed Health Outcomes & Health Determinants. Initial QoL data was ranked in the bottom half of the state, while 70% of original determinant data was also ranked in the bottom half of reported metrics. Dental hygienists in public health settings can positively affect patients offering preventive care outreach services. Education and sealant placement were considered effective as measured by access, delivery and, when required, referral for restorative care. Improvement in QoL for individuals was noted through improved health outcomes and determinant metrics.

  3. The Effects of Bougie Diameters on Tissue Oxygen Levels After Sleeve Gastrectomy: A Randomized Experimental Trial

    Directory of Open Access Journals (Sweden)

    Can Konca

    2018-05-01

    Full Text Available Background: Staple-line leak is the most frightening complication of laparoscopic sleeve gastrectomy and several predisposing factors such as using improper staple sizes regardless of gastric wall thickness, narrower bougie diameter and ischemia of the staple line are asserted. Aims: To evaluate the effects of different bougie diameters on tissue oxygen partial pressure at the esophagogastric junction after sleeve gastrectomy. Study Design: A randomized and controlled animal experiment with 1:1:1:1 allocation ratio. Methods: Thirty-two male Wistar Albino rats were randomly divided into 4 groups of 8 each. While 12-Fr bougies were used in groups 1 and 3, 8-Fr bougies were used in groups 2 and 4. Fibrin sealant application was also carried out around the gastrectomy line after sleeve gastrectomy in groups 3 and 4. Burst pressure of gastrectomy line, tissue oxygen partial pressure and hydroxyproline levels at the esophagogastric junction were measured and compared among groups. Results: Mortality was detected in 2 out of 32 rats (6.25% and one of them was in group 2 and the cause of this mortality was gastric leak. Gastric leak was detected in 2 out of 32 rats (6.25%. There was no significant difference in terms of burst pressures, tissue oxygen partial pressure and tissue hydroxyproline levels among the 4 groups. Conclusion: The use of narrower bougie along with fibrin sealant has not had a negative effect on tissue perfusion and wound healing.

  4. Causes of poor sealant performance in soil gas resistant foundations

    International Nuclear Information System (INIS)

    Scott, A.

    1993-01-01

    The surface permeability of concrete walls and floors in houses was measured with a specially designed permeameter, based on measuring the air-flow induced by a pressure difference across a temporary test seal applied to a surface. The permeability of bulk concrete is 10 -16 m 2 . Areas free of surface defects had permeability ranging from 10 -14 to 10- 16 m 2 . However, surface defects are common on concrete wall surfaces, which increase the permeability to >10 -12 m 2 . This is too high for standard seal designs to be adequate as the only method of soil gas and radon exclusion. Satisfactory seals require either extended contact width or mechanical removal of the surface layer. (orig.). (2 figs., 1 tab.)

  5. Introductory guide to damp in buildings

    CSIR Research Space (South Africa)

    Grobbelaar, C.S

    1975-01-01

    Full Text Available rise-which is exactly how a tree manages to persuade the sap to rise in its trunk. In the ground the tiny spaces between the particles of soil form the "tubes" that lead the ground water up into your house. lf you were surprised to read that a cubic... to the wall. The differing rates of expansion of wood, concrete and brick almostguarantee a crack at this polnt and you should not overlook this when wielding your tube of sealant A Another ilkgal entrant to the building may be the wind...

  6. Feasibility of using overburden clays for sealing purposes and laboratory testing of the clays

    Energy Technology Data Exchange (ETDEWEB)

    Mann, J. (Vyzkumny Ustav pro Hnede Uhli, Most (Czechoslovakia))

    1992-03-01

    Studies properties of overburden clay from North Bohemian surface coal mines for use as sealants of industrial and household waste that will be dumped at Czechoslovak surface mine sites. Basic requirements of sealing layers are optimum compressibility and impermeability by suitable compacting. Laboratory soil mechanical tests of different clay samples were carried out using the Proctor standard tests (PCS) and the Norwegian Geonor A/S - m 45 instrument. Laboratory tests were used to select the best available clay types with optimum density and moisture content. Experimental results of laboratory tests are provided.

  7. Long-term monitoring of microleakage of dental cements by radiochemical diffusion

    International Nuclear Information System (INIS)

    Powis, D.R.; Prosser, H.J.; Wilson, A.D.

    1988-01-01

    Radioactive 14 C sucrose was found to be an ideal marker for microleakage because it did not penetrate tooth tissue, dental cement, or mounting resin. The main finding is that the adhesive cements--the glass-ionomer and polycarboxylate--are significantly more effective at preventing microleakage than are the traditional phosphate cements--silicate and zinc phosphate. The differences can be as high as two orders of magnitude. The adhesive cements provide almost perfect and reliable seals. By contrast, the nonadhesive cements are erratic sealants with most of the restorations leaking

  8. Synthesis characterization, and properties of rubber lattices; a review

    International Nuclear Information System (INIS)

    Khan, S.M.; Chughtai, A.; Sattar, A.

    2008-01-01

    Latex is a stable dispersion of polymeric material in an aqueous medium. Lattices are present in natural as well as in synthetic forms. The range of applications of latex is extensive in carpet underlay, fabric back-coating, paper and paints coatings, adhesive, binder, leather finish, floor polish, waterproof clothing, bounded fiber, pigment printing, latex thread, cement and asphalt, foam scraps binders, can closure, thickeners, box toes and shoes counters, sealant and mastics, modifiers, protein reduction, enzyme treatment and peroxide vulcanization. In this review we are presenting synthesis, characterization, properties, manufacturing and processing of latex. (author)

  9. SEALING SIMULATED LEAKS

    Energy Technology Data Exchange (ETDEWEB)

    Michael A. Romano

    2004-09-01

    This report details the testing equipment, procedures and results performed under Task 7.2 Sealing Simulated Leaks. In terms of our ability to seal leaks identified in the technical topical report, Analysis of Current Field Data, we were 100% successful. In regards to maintaining seal integrity after pigging operations we achieved varying degrees of success. Internal Corrosion defects proved to be the most resistant to the effects of pigging while External Corrosion proved to be the least resistant. Overall, with limitations, pressure activated sealant technology would be a viable option under the right circumstances.

  10. The 'E' factor -- evolving endodontics.

    Science.gov (United States)

    Hunter, M J

    2013-03-01

    Endodontics is a constantly developing field, with new instruments, preparation techniques and sealants competing with trusted and traditional approaches to tooth restoration. Thus general dental practitioners must question and understand the significance of these developments before adopting new practices. In view of this, the aim of this article, and the associated presentation at the 2013 British Dental Conference & Exhibition, is to provide an overview of endodontic methods and constantly evolving best practice. The presentation will review current preparation techniques, comparing rotary versus reciprocation, and question current trends in restoration of the endodontically treated tooth.

  11. Health promotion and dental caries.

    Science.gov (United States)

    Maltz, Marisa; Jardim, Juliana Jobim; Alves, Luana Severo

    2010-01-01

    The central idea of the Brazilian health system is to prevent the establishment of disease or detect it as early as possible. Prevention and treatment of dental caries are related to behavioral factors, including dietary and oral hygiene habits, which are related to many chronic diseases. Dental health promotion therefore should be fully integrated into broadly based health-promoting strategies and actions such as food and health policies, and general hygiene (including oral hygiene), among others. For decades, a linear relationship between sugar consumption and caries has been observed. Recent data has indicated that this relationship is not as strong as it used to be before the widespread use of fluoride. However, diet is still a key factor acting in the carious process. Oral hygiene is a major aspect when it comes to caries, since dental biofilm is its etiological factor. Oral hygiene procedures are effective in controlling dental caries, especially if plaque removal is performed adequately and associated with fluoride. An alternative to a more efficient biofilm control in occlusal areas is the use of dental sealants, which are only indicated for caries-active individuals. If a cavity is formed as a consequence of the metabolic activity of the biofilm, a restorative material or a sealant can be placed to block access of the biofilm to the oral environment in order to prevent caries progress. The prevention of dental caries based on common risk-factor strategies (diet and hygiene) should be supplemented by more disease-specific policies such as rational use of fluoride, and evidence-based dental health care.

  12. Health promotion and dental caries

    Directory of Open Access Journals (Sweden)

    Marisa Maltz

    2010-01-01

    Full Text Available The central idea of the Brazilian health system is to prevent the establishment of disease or detect it as early as possible. Prevention and treatment of dental caries are related to behavioral factors, including dietary and oral hygiene habits, which are related to many chronic diseases. Dental health promotion therefore should be fully integrated into broadly based health-promoting strategies and actions such as food and health policies, and general hygiene (including oral hygiene, among others. For decades, a linear relationship between sugar consumption and caries has been observed. Recent data has indicated that this relationship is not as strong as it used to be before the widespread use of fluoride. However, diet is still a key factor acting in the carious process. Oral hygiene is a major aspect when it comes to caries, since dental biofilm is its etiological factor. Oral hygiene procedures are effective in controlling dental caries, especially if plaque removal is performed adequately and associated with fluoride. An alternative to a more efficient biofilm control in occlusal areas is the use of dental sealants, which are only indicated for caries-active individuals. If a cavity is formed as a consequence of the metabolic activity of the biofilm, a restorative material or a sealant can be placed to block access of the biofilm to the oral environment in order to prevent caries progress. The prevention of dental caries based on common risk-factor strategies (diet and hygiene should be supplemented by more disease-specific policies such as rational use of fluoride, and evidence-based dental health care.

  13. Polymers Advance Heat Management Materials for Vehicles

    Science.gov (United States)

    2013-01-01

    For 6 years prior to the retirement of the Space Shuttle Program, the shuttles carried an onboard repair kit with a tool for emergency use: two tubes of NOAX, or "good goo," as some people called it. NOAX flew on all 22 flights following the Columbia accident, and was designed to repair damage that occurred on the exterior of the shuttle. Bill McMahon, a structural materials engineer at Marshall Space Flight Center says NASA needed a solution for the widest range of possible damage to the shuttle s exterior thermal protection system. "NASA looked at several options in early 2004 and decided on a sealant. Ultimately, NOAX performed the best and was selected," he says. To prove NOAX would work effectively required hundreds of samples manufactured at Marshall and Johnson, and a concerted effort from various NASA field centers. Johnson Space Center provided programmatic leadership, testing, tools, and crew training; Glenn Research Center provided materials analysis; Langley Research Center provided test support and led an effort to perform large patch repairs; Ames Research Center provided additional testing; and Marshall provided further testing and the site of NOAX manufacturing. Although the sealant never had to be used in an emergency situation, it was tested by astronauts on samples of reinforced carbon-carbon (RCC) during two shuttle missions. (RCC is the thermal material on areas of the shuttle that experience the most heat, such as the nose cone and wing leading edges.) The material handled well on orbit, and tests showed the NOAX patch held up well on RCC.

  14. Superparamagnetic iron oxide nanoparticles function as a long-term, multi-modal imaging label for non-invasive tracking of implanted progenitor cells.

    Directory of Open Access Journals (Sweden)

    Christina A Pacak

    Full Text Available The purpose of this study was to determine the ability of superparamagnetic iron oxide (SPIO nanoparticles to function as a long-term tracking label for multi-modal imaging of implanted engineered tissues containing muscle-derived progenitor cells using magnetic resonance imaging (MRI and X-ray micro-computed tomography (μCT. SPIO-labeled primary myoblasts were embedded in fibrin sealant and imaged to obtain intensity data by MRI or radio-opacity information by μCT. Each imaging modality displayed a detection gradient that matched increasing SPIO concentrations. Labeled cells were then incorporated in fibrin sealant, injected into the atrioventricular groove of rat hearts, and imaged in vivo and ex vivo for up to 1 year. Transplanted cells were identified in intact animals and isolated hearts using both imaging modalities. MRI was better able to detect minuscule amounts of SPIO nanoparticles, while μCT more precisely identified the location of heavily-labeled cells. Histological analyses confirmed that iron oxide particles were confined to viable, skeletal muscle-derived cells in the implant at the expected location based on MRI and μCT. These analyses showed no evidence of phagocytosis of labeled cells by macrophages or release of nanoparticles from transplanted cells. In conclusion, we established that SPIO nanoparticles function as a sensitive and specific long-term label for MRI and μCT, respectively. Our findings will enable investigators interested in regenerative therapies to non-invasively and serially acquire complementary, high-resolution images of transplanted cells for one year using a single label.

  15. Robotics in space-age manufacturing

    Science.gov (United States)

    Jones, Chip

    1991-01-01

    Robotics technologies are developed to improve manufacturing of space hardware. The following applications of robotics are covered: (1) welding for the space shuttle and space station Freedom programs; (2) manipulation of high-pressure water for shuttle solid rocket booster refurbishment; (3) automating the application of insulation materials; (4) precision application of sealants; and (5) automation of inspection procedures. Commercial robots are used for these development programs, but they are teamed with advanced sensors, process controls, and computer simulation to form highly productive manufacturing systems. Many of the technologies are also being actively pursued in private sector manufacturing operations.

  16. Twenty-month follow-up of occlusal caries lesions deemed questionable at baseline

    DEFF Research Database (Denmark)

    Makhija, Sonia K; Gilbert, Gregg H; Funkhouser, Ellen

    2014-01-01

    -three clinicians from The National Dental Practice-Based Research Network participated in this study, recording lesion characteristics at baseline and lesion status at 20 months. RESULTS: At baseline, 1,341 QOC lesions were examined; the treatment that was planned for 1,033 of those at baseline was monitoring...... (oral hygiene instruction, applying or prescribing fluoride or varnish, or both), and the remaining 308 received a sealant (n = 192) or invasive therapy (n = 116). At the 20-month visit, clinicians continued to monitor 927 (90 percent) of the 1,033 monitored lesions. Clinicians decided to seal 61 (6...

  17. Hazardous properties and environmental effects of materials used in solar heating and cooling (SHAC) technologies: interim handbook

    Energy Technology Data Exchange (ETDEWEB)

    Searcy, J.Q.

    1978-12-01

    General background informaion related to SHAC systems, how a particular material was chosen for this handbook, and codes and standards are given. Materials are categorized according to their functional use in SHAC systems as follows: (1) heat transfer fluids and fluid treatment chemicals, (2) insulation materials, (3) seals and sealant materials, (4) glazing materials, (5) collector materials, and (6) storage media. The informaion is presented under: general properties, chemical composition, thermal degradation products, and thermoxidative products of some commercial materials; toxic properties and other potential health effects; fire hazard properties; and environmental effects of and disposal methods for SHAC materials. (MHR)

  18. [Indoor air pollution by polychlorinated biphenyl compounds in permanently elastic sealants].

    Science.gov (United States)

    Burkhardt, U; Bork, M; Balfanz, E; Leidel, J

    1990-10-01

    A common cause for indoor pollution by polycholorinated biphenyls (PCB) are defective capacitors of luminous discharge lamps. This paper describes elastic sealing compounds as another source of PCB pollution in buildings. In several rooms of a large school building indoor concentrations of 1000 ng PCB/m3 and more were registered. The total PCB concentration in sealing compounds ranged between 124,000 and 327,000 ppm. Blood specimens drawn from the school's personnel did not show elevated PCB concentrations, but additional incorporation of PCB via the respiratory tract cannot be excluded. We do not presume that any impairment of the health has been caused by this pollutant, but we think that reduction of the PCB indoor concentrations would be advisable for prophylactic purposes. Attention should be given to so-called open PCB systems such as elastic sealing compounds. Although they have been prohibited 1978, there might be a widespread use in older buildings.

  19. Fracture toughness of glass sealants for solid oxide fuel cell application

    DEFF Research Database (Denmark)

    Abdoli, Hamid; Alizadeh, Parvin; Boccaccini, Dino

    2014-01-01

    -opening displacements in the near regions of a crack tip. Both approaches exhibited good agreement. La-containing glass showed higher stiffness, hardness and fracture toughness, which has been related to the in-situ toughening mechanism caused by devitrification and formation of crystalline phases. © 2013 Elsevier B.V....

  20. Mesoporous TiO{sub 2} nanoparticles for highly sensitive solid-phase microextraction of organochlorine pesticides

    Energy Technology Data Exchange (ETDEWEB)

    Liu, Shuqin; Xie, Lijun; Zheng, Juan; Jiang, Ruifeng; Zhu, Fang; Luan, Tiangang; Ouyang, Gangfeng, E-mail: cesoygf@mail.sysu.edu.cn

    2015-06-09

    Highlights: • Mesoporous TiO{sub 2} nanoparticles were synthesized and characterized. • A novel SPME fiber was fabricated with silicone sealant film and TiO{sub 2} powder. • The fiber exhibited excellent extraction performance to OCPs. • The fiber was used for analysis of OCPs in real water samples. - Abstract: Mesoporous TiO{sub 2} nanoparticles were synthesized with the hydrothermal method and characterized by powder X-ray diffraction (PXRD) and transmission electron microscope (TEM). Then a superior solid-phase microextraction (SPME) fiber was fabricated by sequentially coating the stainless steel fiber with silicone sealant film and mesoporous TiO{sub 2} powder. The developed fiber possessed a homogeneous surface and a long life-span up to 100 times at direct immersing (DI) extraction mode. Under the optimized conditions, the extraction efficiencies of the self-made 17 μm TiO{sub 2} fiber for six organochlorine pesticides (OCPs) were higher than those of the two commercial fibers (65 μm PDMS/DVB and 85 μm PA fibers) which were much thicker than the former. As for analytical performance, low detection limits (0.08–0.60 ng L{sup −1}) and wide linearity (5–5000 ng L{sup −1}) were achieved under the optimal conditions. The repeatabilities (n = 5) for single fiber were between 2.8 and 12.3%, while the reproducibilities (n = 3) of fiber-to-fiber were in the range of 3.7–15.7%. The proposed fiber was successfully applied to the sensitive analysis of OCPs in real water samples and four of the six analytes were detected from the rainwater and the lake water samples.

  1. SCHOOL DIETARY HABITS AND INCIDENCE OF DENTAL CARIES.

    Science.gov (United States)

    Monteagudo, Celia; Téllez, Francisco; Heras-González, Leticia; Ibañez-Peinado, Diana; Mariscal-Arcas, Miguel; Olea-Serrano, Fatima

    2015-07-01

    healthy dietary habits are considered to improve oral health and tooth quality. Caries treatment comprises tooth restoration with dental composites and sealants, almost all (> 90%) of which contain bisphenol A (BPA). Study hypotheses were: a) breakfast and oral hygiene habits are important factors in dental caries development; and b) dental caries treatment with epoxy-resins entails a risk of oral exposure to monomers migrating from the polymeric material. We evaluated caries in the teeth of a Spanish school population and determined the percentage treated with dental composites. to relate consumption of breakfast components and oral hygiene habits to dental caries and determine the presence of sealants/composites as potential sources of BPA exposure. subjects: 582 schoolchildren from Granada city (Southern Spain) aged 7 yrs; mean (SD) of 7.55 (0.64) yrs. caries was detected in 21.7% of their teeth. Mean breakfast quality index (BQI) score, based on nutritional questionnaires, was 5.18 (1.29). Breakfast with foods rich in simple sugars representing > 5% of total daily energy was consumed by 24% of the population and was significantly associated with caries frequency in binary logistic regression analysis. Biscuit consumption was reported by 35.8% and significantly associated with caries frequency. Breakfast intake of bakery products/ cereals and of dairy products showed a significant inverse association with caries frequency. No significant relationship was observed between caries and BQI score or oral hygiene factors. further research is required to elucidate the role of diet in caries and the associated risk of exposure to estrogenic xenobiotics such as BPA. Copyright AULA MEDICA EDICIONES 2014. Published by AULA MEDICA. All rights reserved.

  2. Diisocyanate emission from a paint product: a preliminary analysis.

    Science.gov (United States)

    Jarand, Curtis W; Akapo, Samuel O; Swenson, Lonie J; Kelman, Bruce J

    2002-07-01

    Exposure of workers to diisocyanates in the polyurethane foam manufacturing industry is well documented. However, very little quantitative data have been published on exposure to diisocyanates from the use of paints and coatings. The purpose of this study was to evaluate emission of 2,4-toluene diisocyanate, 2,6-toluene diisocyanate (2,6-TDI), and isophorone diisocyanate from a commercially available two-stage concrete coating and sealant. A laboratory model of an outdoor deck coating process was developed and diisocyanate concentrations determined by derivatization with 1-(2-methoxyphenol)-piperazine and subsequent high performance liquid chromatographic analysis with UV detection. The detection limit for 2,4-toluene diisocyanate and 2,6-toluene diisocyanate urea derivatives was 0.6 microg TDI/gm wet product, and 0.54 microg IPDI/gm wet product for the isophorone diisocyanate urea derivative. No 2,4-toluene diisocyanate or isophorone diisocyanate was detected in the mixed product. A maximum mean 2,6-TDI emission rate of 0.32 microg of 2,6-TDI/gram of wet product applied/hour was observed for the 1-hour sampling time, 0.38 microg of 2,6-TDI/gram of wet product applied/hour was observed for the 5-hour sampling time, and 0.02 micrpg of 2,6-TDI/gram of wet product applied/hour was observed for the 15-hour sampling time. The decrease in rate of 2,6-TDI emission over the 15-hour period indicates that emission of 2,6-TDI is virtually complete after 5 hours. These emission rates should allow industrial hygienists to calculate exposures to isocyanates emitted from at least one curing sealant.

  3. Process for making propenyl ethers and photopolymerizable compositions containing them

    Science.gov (United States)

    Crivello, James V.

    1996-01-01

    Propenyl ether monomers of formula V A(OCH.dbd.CHCH.sub.3).sub.n wherein n is an integer from one to six and A is selected from cyclic ethers, polyether and alkanes are disclosed. The monomers are readily polymerized in the presence of cationic photoinitiators, when exposed to actinic radiation, to form poly(propenyl ethers) that are useful for coatings, sealants, varnishes and adhesives. Compositions for preparing polymeric coatings comprising the compounds of formula V together with particular cationic photoinitiators are also disclosed, as are processes for making the monomers from allyl halides and readily available alcohols. The process involves rearranging the resulting allyl ethers to propenyl ethers.

  4. Technical and economic assessment for asbestos abatement within Facility 20470, Wright-Patterson Air Force Base, Ohio

    International Nuclear Information System (INIS)

    Gibson, S.M.; Ogle, R.B.

    1988-03-01

    This report presents the results of a technical and economic assessment of available alternatives for asbestos abatement within Facility 20470 at the Wright-Patterson Air Force Base in Dayton, Ohio. Each alternative was screened on the basis of technical feasibility, environmental impact, economics, and fulfillment of the IRP goals. Four alternatives for study are: establishing a special operations and maintenance program; enclosure; encapsulation with sealants; and removal, disposal, and replacement. Each of these alternatives was assessed for capability to control the release of asbestos fibers within Facility 20470. Alternatives 1 and 4 were determined to be acceptable, while Alternatives 2 and 3 were found to be unacceptable. 2 refs., 6 figs

  5. Ignition of Fuel Vapors Beneath Titanium Aircraft Skins Exposed to Lightning

    Science.gov (United States)

    Kosvic, T. C.; Helgeson, N. L.; Gerstein, M.

    1971-01-01

    Hot-spot and puncture ignition of fuel vapors by simulated lightning discharges was studied experimentally. The influences of skin coating, skin structure, discharge polarity, skin thickness, discharge current level, and current duration were measured and interpreted. Ignition thresholds are reported for titanium alloy constructed as sheets, sheets coated with sealants, and sandwich skins. Results indicated that the ignition threshold charge transfer for coated sheets, honeycomb, and truss skins is respectively about 200%, 400%, 800% that of bare alloy sheet of .102 cm (.040 in.)-thickness. It was found that hot-spot ignition can occur well after termination of the arc, and that sandwich materials allow ignition only if punctured.

  6. Fluorides and Other Preventive Strategies for Tooth Decay.

    Science.gov (United States)

    Horst, Jeremy A; Tanzer, Jason M; Milgrom, Peter M

    2018-04-01

    We focus on scalable public health interventions that prevent and delay the development of caries and enhance resistance to dental caries lesions. These interventions should occur throughout the life cycle, and need to be age appropriate. Mitigating disease transmission and enhancing resistance are achieved through use of various fluorides, sugar substitutes, mechanical barriers such as pit-and-fissure sealants, and antimicrobials. A key aspect is counseling and other behavioral interventions that are designed to promote use of disease transmission-inhibiting and tooth resistance-enhancing agents. Advocacy for public water fluoridation and sugar taxes is an appropriate dental public health activity. Copyright © 2017 Elsevier Inc. All rights reserved.

  7. Preliminary evaluation of the control of indoor radon daughter levels in new structures

    International Nuclear Information System (INIS)

    Fitzgerald, J.E. Jr.; Guimond, R.J.

    1976-01-01

    As part of its assessment of the radiological impact of the phosphate industry in Florida, the US Environmental Protection Agency has surveyed residences built atop uraniferous reclaimed phosphate mining land. These surveys have shown elevated radon daughter levels to exist in structures built on this land. In order to allow safer use of this land for residential construction, various state-of-the-art radon daughter control technologies were evaluated by the Agency. These included forced ventilation, polymeric sealants, excavation, crawl space construction, and improved slab quality. From a cost-effectiveness evaluation, improved slab quality and crawl space construction were determined to best satisfy the criteria for optimal radon daughter control

  8. Development of puncture resistance tire tube; Nirinsha no taipankusei kojo cube no kaihatsu

    Energy Technology Data Exchange (ETDEWEB)

    Yamagiwa, T; Nakayama, K; Kiyota, S; Tanaka, A [Honda R and D Co. Ltd., Tokyo (Japan); Makisaka, N

    1997-10-01

    A new tire tube with a puncture resistance function was developed. The tube is a two-chamber structure having an air chamber and a liquid chamber, and the liquid chamber at the crown-side half of the tube is filled with an anti-puncture sealant during a manufacturing process. In a market test, it was confirmed that the number of puncture cases were reduced by 90 % in comparison with conventional tire tubes by using the newly developed tube. This paper describes the structure of the tube and the characteristics of the tube rubber, and the manufacturing process and durability of the tube. 3 refs., 17 figs.

  9. The relationship between diet and Dental Caries

    International Nuclear Information System (INIS)

    Duggal, M. S

    1991-01-01

    Dental caries is a disease of multifactorial etiology and results from a complex interaction between both cariogenic and protective influences acting on the teeth. Though diet plays a major role in the causation of dental caries it has been a common mistake to over-simplify the relationship. Dietary manipulation is also extremely difficult to achieve thus limiting its role in the prevention of caries. Accordingly, alternative preventive measures such as the use of fissure sealants and fluoride which enhance the resistance of the host to disease and are of proven efficacy are more likely to be successful in the control and prevention of dental caries. (author)

  10. Automation Study for Longhorn Army Ammunition Plant Hand Held Signal Flight Assembly, Rocket Barrel Assembly, 40 MM Signal, Final Packaging/Pack-Out, and Star Finishing

    Science.gov (United States)

    1990-03-01

    wood protectors in the HHS Rocket Barrel Assembly Operations. d) Use of hot melt sealant rather than lacquer on the end of the assembled Hand Held...4OL.UA8LYADHRlE CG411!cLVPAM-1 ~LW7m~I~o~c~c LCA ~TM18UX"Y.31nSRGU-11 STiIM ASSELYJMACE FINh1TZ1A1*4CWAJKRZAM’ WAOiNt rs~my" LOCATM1ED 0~7 LOCA1ED’ IWCM-1W...Moorfeed Fairview, PA Indianapolis, IN Voice Synthesis Module Square D Micro Chip Technology Palatine, IL Chandler, AZ 85224 Vacuum Unit Venturi’s

  11. Army Programmatic Environmental Assessment of the Mine Resistant Ambush Protected (MRAP) Vehicle Program

    Science.gov (United States)

    2010-12-01

    Petroleum distillates  Powertrain  Pro Lock Pipe Sealant  Polyfunctional Dimethyacrylate esters  Mechanical  TT‐E‐529G Yellow  Enamel   Petroleum...907E)  Petroleum oil, Copper powder   Mechanical  White  Enamel   Toluene, Acetone, Xylene, Propane, Isobutane, n‐ Butane, Ethylbenzene, Petroleum...Diatomaceous earth, Yellow Iron   Oxide Pigment   External finish paint  Penetrant, Liquid    Surface  Crack  detector  Penetrant, Liquid    Used to

  12. Crystallization behaviors and seal application of basalt based glass-ceramics

    Science.gov (United States)

    Ateş, A.; Önen, U.; Ercenk, E.; Yılmaz, Ş.

    2017-02-01

    Basalt based glass-ceramics were prepared by conventional melt-quenching technique and subsequently converted to glass-ceramics by a controlled nucleation and crystallization process. Glass materials were obtained by melt at 1500°C and quenched in cold water. The powder materials were made by milling and spin coating. The powders were applied on the 430 stainless steel interconnector material, and heat treatment was carried out. The interface characteristics between the glass-ceramic layer and interconnector were investigated by using X-ray diffraction analysis (XRD) and scanning electron microscopy (SEM). The results showed that the basalt base glass-ceramic sealant material exhibited promising properties to use for SOFC.

  13. Barium boron silicate glass-ceramic for use as sealant in planar SOFC

    International Nuclear Information System (INIS)

    Silva, M.J.; Castanho, S.R.H. Mello; Reis, S.T.

    2012-01-01

    Glass-ceramic seals play an important role in the performance of the solid oxide fuel cell (SOFC). In this work glass-ceramic seals are discussed from the point of view of the thermal behavior of the glass and the electrochemical parameters obtained from polarization curves such as corrosion current densities (i corr ), and corrosion potential (E corr ). A seal material must have a combination of thermal-mechanical and electrochemical properties in order to seal cell components and stacks and prevent side reactions. It must be stable in oxidizing and reducing atmospheres and withstand thermal cycles between room temperature and the cell operating temperature (800 to 900°C). Glass-ceramics in the system BaO- B 2 O 3 -Al 2 O 3 -SiO 2 were investigated and compared from the point of view of sealing ability. Dilatometric analysis, thermal stability against crystallization, microstructure and electrochemical durability are discussed. (author)

  14. Meta-analysis of dry cow management for dairy cattle. Part 1. Protection against new intramammary infections.

    Science.gov (United States)

    Halasa, T; Osterås, O; Hogeveen, H; van Werven, T; Nielen, M

    2009-07-01

    The objective of this study was to estimate the preventive effect of various dry cow management measures against quarter new intramammary infections (IMI) during the dry period up to 21 d postcalving. Moreover, the potential publication bias was assessed in the studies selected for this analysis. The intervention measures were blanket dry cow therapy (BDCT), selective dry cow therapy (SDCT), cloxacillin compared with other dry cow therapy products, and teat sealant. A meta-analysis relative risk (RR) was calculated per intervention and pathogen group when enough studies were available from the 33 selected studies. Results of the meta-analyses were examined using publication bias tests. Blanket dry cow therapy showed significant protection against new IMI caused by Streptococcus spp. [the pooled RR was 0.39 (0.30 to 0.51)] but no protection was observed against coliform new IMI [the pooled RR was 0.95 (0.81 to 1.10)]. After correction for publication bias, it became doubtful whether DCT is protective against new Staphylococcus spp. IMI. Cloxacillin showed similar protection against new quarter IMI compared with other DCT products [the pooled RR was 1.09 (0.94 to 1.25)]. Selective dry cow therapy showed higher protection against new IMI compared with no DCT [the pooled RR was 0.51 (0.30 to 0.86)]. However, BDCT showed more protection when compared with SDCT [the pooled RR was 0.55 (0.37 to 0.80)], but the inference about whether BDCT is superior to SDCT was dependent on whether the selection criteria for SDCT was at the cow or quarter level. Internal teat sealants showed significant protection against new IMI during the dry period [the pooled RR was 0.39 (0.18 to 0.82)]. Publication bias should be taken into account when attempts are made to review literature in a meta-analysis.

  15. Managing molar-incisor hypomineralization: A systematic review.

    Science.gov (United States)

    Elhennawy, Karim; Schwendicke, Falk

    2016-12-01

    We systematically reviewed treatment modalities for MIH-affected molars and incisors. Trials on humans with ≥1 MIH molar/incisor reporting on various treatments were included. Two authors independently searched and extracted records. Sample-size-weighted annual failure rates were estimated where appropriate. The risk of bias was assessed using the Newcastle-Ottawa scale. Electronic databases (PubMed, Embase, Cochrane CENTRAL, Google Scholar) were screened, and hand searches and cross-referencing performed. Fourteen (mainly observational) studies were included. Ten trials (381 participants) investigated MIH-molars, four (139) MIH-incisors. For molars, remineralization, restorative or extraction therapies had been assessed. For restorative approaches, mean (SD) annual failure rates were highest for fissure sealants (12[6]%) and glass-ionomer restorations (12[2]%), and lowest for indirect restorations (1[3]%), preformed metal crowns (1.3 [2.1]%) and composite restorations (4[3]%). Ony study assessed extraction of molars in young patients (median age 8.2 years), the majority of them without malocclusions, but third molars in development. Spontaneous alignment of second molars was more frequent in the maxilla (55%) than the mandible (47%). For incisors, desensitizing agents successfully managed hypersensitivity. Micro-abrasion and composite veneers improved aesthetics. Few, mainly moderate to high-risk-studies investigated treatment of MIH. Remineralization or sealants seem suitable for MIH-molars with limited severity and/or hypersensitivity. For severe cases, restorations with composites or indirect restorations or preformed metal crowns seem suitable. Prior to tooth extraction as last resort factors like the presence of a general malocclusion, patients' age and the status of neighboring teeth should be considered. No recommendations can be given for MIH-incisors. Dentists need to consider the specific condition of each tooth and the needs and expectations of

  16. TachoSil use in abdominal surgery: a review

    Directory of Open Access Journals (Sweden)

    Giulio Reale

    2011-03-01

    Full Text Available Adriana Toro, Maurizio Mannino, Giulio Reale, Isidoro Di CarloDepartment of Surgical Sciences, Organ Transplantation, and Advanced Technologies, University of Catania, Cannizzaro Hospital, Catania, ItalyAbstract: The success of any surgical procedure is based on adequate hemostasis. Many different biomaterial products can be used to achieve that aim. The products that can be used during surgery may be classified as topical hemostats, sealants, and adhesives. Hemostats can clot blood. Sealants can create sealing barriers. Adhesives bond tissue together. Collagen, gelatin, and cellulose are hemostat agents. TachoSil® is a development of TachoComb® and TachoComb® H. TachoComb is made with equine collagen, bovine thrombin, bovine aprotinin, and human fibrinogen. The clinical efficacy of TachoSil was shown firstly by a clinical study of hepatic surgery. In the study, TachoSil proved to be superior to argon beamer in obtaining effective and fast intraoperative hemostasis. Following the study, many applications in different fields of surgery have been reported in the literature. The use of TachoSil in open abdominal surgery and its relevant results have encouraged the use of TachoSil in laparoscopic surgery. Unfortunately, its use in laparoscopy has not become as popular as it is in open surgery, due to a lack of efficacious techniques. Immunologic reactions to compounds of TachoSil and the transmission of infectious diseases are two major risks concerning topical hemostasis. Even though the risk of severe immunologic reactions to bovine material is low, TachoSil has gradually replaced all bovine material with material of human origin and has therefore eliminated the associated risks of bovine material. TachoSil has a good satisfaction rate among surgeons and reduces both the operating time for patients and the time spent in intensive care units.Keywords: TachoSil, abdominal surgery, hemostasis

  17. EFEKIVITAS BIAYA MODEL PENCEGAHAN KARIES DAN GINGIVITIS PADA PROGRAM UKGS DKI JAKARTA

    Directory of Open Access Journals (Sweden)

    Laksmi Dwiati

    2015-07-01

    Full Text Available In dental health community programmes there are several kind of efficiency application patron such as dental health programme worthy to do, like comparing various alternatives procedures in a dental health programmes. Cost effectiveness analysis (CEA is becoming increasingly popular as society moved toward rationalizing dental health cost to optimized programmes. CEA compares the cost of procedure with its effectiveness thus helping an adiminstrator to judge whether the procedure is worth itrs cost. CEA also permit comparison of various interventions that result in a similar dental health outcome. A major benefit of CEA is that it forces decision maker to confront the trade-offs implicit in all decision regarding alternative approaches. Caries dentis and gingivitis are still aserious oral health problem to solve especially for primary school student. Curative effort is relative more expensive, so it was chosen alternative for preventing caries must be together with preventing gingivtis. The purpose of the research is gerring the cost effective moel of preventive caries and gingivitis for a primary school student at DKI Jakarta. The opportunity cost of alternative model preventive caries and gingivitis intervention such a modern dentistry approach (Fissure Sealant and Oral-Hygiene instruction procedures by the dentist to compare against model routine intervention approach (fluoride mouth rinsing and ART procedures by the full time dentist or by dentist together with teachers along with the relative effectiveness of preventive treatment. In this quasi experiment research with multistage randomized designed we use respondent of all primary school student in DKI Jakarta for two different treatment group. Fissure Sealant and Oral Hygiene Instruction procedures by the Dentist were judged to be more cost effective than fluoride mouthrinsing and ART procedures by the dentist together with teachers, or by the full time dentist.

  18. Fuel property effects on Navy aircraft fuel systems

    Science.gov (United States)

    Moses, C. A.

    1984-01-01

    Problems of ensuring compatibility of Navy aircraft with fuels that may be different than the fuels for which the equipment was designed and qualified are discussed. To avoid expensive requalification of all the engines and airframe fuel systems, methodologies to qualify future fuels by using bench-scale and component testing are being sought. Fuel blends with increasing JP5-type aromatic concentration were seen to produce less volume swell than an equivalent aromatic concentration in the reference fuel. Futhermore, blends with naphthenes, decalin, tetralin, and naphthalenes do not deviate significantly from the correlation line of aromatic blends, Similar results are found with tensile strenth and elongation. Other elastomers, sealants, and adhesives are also being tested.

  19. Field applications of a radon barrier to reduce indoor airborne progeny

    International Nuclear Information System (INIS)

    Culot, M.V.J.; Olson, H.G.; Schiager, K.J.

    1978-01-01

    The use of uranium mill tailings in the foundations of dwellings has resulted in indoor radon progeny concentrations and gamma exposures in excess of levels presently allowed for the general public. An account is given of the applications of an epoxy coating on the indoor faces of the concrete foundations of three buildings in Grand Junction, Colorado. Epoxy barriers were shown to be effective for preventing radon influx into structures. Gamma exposure rates must be analyzed to ensure that buildup behind the barrier will not introduce an unacceptable gamma exposure level. The use of a sealant is especially economical in situations where structural integrity may be jeopardized by physical removal of uranium mill tailings. (author)

  20. Results of the freeze resistance test, swelling index and coefficient of permeability of finegrained mining waste reinforced with cements

    Science.gov (United States)

    Morman, Justyna

    2018-04-01

    The article presents the result of laboratory tests for mining waste with grain size of 0 to 2 mm stabilized with cement. Used for stabilization of cement CEM I 42.5 R and blast furnace cement CEM III / A 42.5N - LH / HSR / NA and a plasticizer sealant. Cement was added to the mining waste test in the proportions of 5 - 8% in relation to the skeleton's weight. For the cemented samples, the freeze resistance test, swelling index, coefficient of permeability and pH of water leachate were tested. The addition of a cement binder resulted in diminishing the water permeability of mining waste and limiting the leaching of fine particles from the material.

  1. Dental caries and treatment needs of children (6-10 years in rural Udaipur, Rajasthan

    Directory of Open Access Journals (Sweden)

    Dhar Vineet

    2009-01-01

    Full Text Available Objective : This study was done to examine caries prevalence and corresponding treatment needs in school children of rural areas of Udaipur, Rajasthan. Materials and Methods : A total of 750 children of rural areas in the age group of 6-10 years were examined, using WHO index, to record the prevalence of dental caries and treatment needs. The results were subjected to statistical analysis using chi square test. Results : Dental caries was found in 63.20% children, and 85.07% children needed dental treatment. The highest need was of one surface filling (85.73% followed by sealant (51.20%. Conclusion : Dental caries showed to be a significant health issue in the rural population requiring immediate attention.

  2. CMHC research project: Testing of air barriers construction details: Report

    Energy Technology Data Exchange (ETDEWEB)

    1991-01-01

    This project was conducted to quantify the air leakage characteristics of the header joist, the electric outlets, and the window openings in wood-frame walls. The study evaluated the sealed internal membrane method, where polyethylene sheet and sealant provide the air barrier; the external air barrier method, which uses a continuous vapour permeable membrane (spun-bonded olefin film), sandwiched between two layers of external wall sheathing; and the airtight drywall method, where the interior gypsum board finish, together with framing materials and gaskets, are used as the air barrier. In addition, the traditional approach to wood-frame wall construction, where no special attention is given to achieving a continuous air barrier, was evaluated for comparison.

  3. Formation of magnetic aluminium oxyhydroxide nanorods and use for hyperthermal effects

    International Nuclear Information System (INIS)

    Jha, Himendra; Schmidt-Stein, Felix; Shrestha, Nabeen K; Schmuki, Patrik; Kettering, Melanie; Hilger, Ingrid

    2011-01-01

    In the present work, we show that a porous alumina template can easily be filled with magnetic nanoparticles and then be sealed by a hot water treatment (by forming an aluminium oxyhydroxide (AlOOH) sealant layer). The porous layer then can be separated from the substrate by an etch to form free magnetic AlOOH nano-capsules. The process allows for a straightforward and highly defined size control of the magnetic units and can easily be scaled up. Furthermore, as AlOOH is biocompatible and has been used as a drug adjuvant for human use, the nanorod shaped capsules are highly promising for biomedical applications such as hyperthermal effects (heating in alternating magnetic fields).

  4. An Ultrasonic Wheel-Array Probe

    Science.gov (United States)

    Drinkwater, B. W.; Brotherhood, C. J.; Freemantle, R. J.

    2004-02-01

    This paper describes the development and modeling of an ultrasonic array wheel probe scanning system. The system operates at 10 MHz using a 64 element array transducer which is 50 mm in length and located in a fluid filled wheel. The wheel is coupled to the test structure dry, or with a small amount of liquid couplant. When the wheel is rolled over the surface of the test structure a defect map (C-Scan) is generated in real-time. The tyre is made from a soft, durable polymer which has very little acoustic loss. Two application studies are presented; the inspection of sealant layers in an aluminum aircraft wing structure and the detection of embedded defects in a thick section carbon composite sample.

  5. Revegetation and rock cover for stabilization of inactive uranium mill tailings disposal sites. Final report

    Energy Technology Data Exchange (ETDEWEB)

    Beedlow, P.A.

    1984-05-01

    Guidelines for using vegetation and rock to protect inactive uranium mill tailings from erosion were developed by Pacific Northwest Laboratory as part of the Department of Energy's Uranium Mill Tailings Remedial Action Project (UMTRAP) Technology Development program. Information on soils, climate, and vegetation were collected for 20 inactive tailings sites in the western United States. Sites were grouped according to similarities in climate and vegetation. Soil loss for those sites was characterized using the Universal Soil Loss Equation. Test plots were used to evaluate (1) the interaction between vegetation and sealant barrier systems and (2) the effects of surface rock on soil water and vegetation. Lysimeter and simulation studies were used to direct and support field experiments. 49 references, 17 figures, 16 tables.

  6. Revegetation and rock cover for stabilization of inactive uranium mill tailings disposal sites. Final report

    International Nuclear Information System (INIS)

    Beedlow, P.A.

    1984-05-01

    Guidelines for using vegetation and rock to protect inactive uranium mill tailings from erosion were developed by Pacific Northwest Laboratory as part of the Department of Energy's Uranium Mill Tailings Remedial Action Project (UMTRAP) Technology Development program. Information on soils, climate, and vegetation were collected for 20 inactive tailings sites in the western United States. Sites were grouped according to similarities in climate and vegetation. Soil loss for those sites was characterized using the Universal Soil Loss Equation. Test plots were used to evaluate (1) the interaction between vegetation and sealant barrier systems and (2) the effects of surface rock on soil water and vegetation. Lysimeter and simulation studies were used to direct and support field experiments. 49 references, 17 figures, 16 tables

  7. Environmental protection systems for the petroleum industry

    International Nuclear Information System (INIS)

    Lowe, G.B.

    1996-01-01

    The transportation of petroleum products and other chemicals can involve spillage and leaks despite being closely controlled. Human error in the loading of road tankers or consumers refuelling their vehicles at service stations can lead to spillage accidents. Seepage through permeable concrete and its expansion joints can occur for diesel underground tanks with serious environmental consequences. This article describes methods which could be adopted by the petroleum industry to prevent these accidental incidents from causing environmental pollution. Service station forecourts could be constructed, using precast concrete hexagonal blocks with dry sand between them and then have a coating of sealant to prevent spills from seeping into ground water. Secondary containment for underground tanks should be given an elastomeric membrane coating. (UK)

  8. Spacer Thickness-Dependent Electron Transport Performance of Titanium Dioxide Thick Film for Dye-Sensitized Solar Cells

    Directory of Open Access Journals (Sweden)

    Reda E. El-Shater

    2015-01-01

    Full Text Available A titanium dioxide (P25 film was deposited by cast coating as conductive photoelectrode and subsequently immersed in dye solution (N719 to fabricate the photoanode of dye-sensitized solar cells (DSSCs. A plastic spacer was used as a separation and sealant layer between the photoanode and the counter electrode. The effect of the thickness of this spacer on the transfer of electrons in the liquid electrolyte of the DSSCs was studied by means of both IV curves and electrochemical impedance. Using a spacer thickness range of 20 μm to 50 μm, efficiency ranges from 3.73% to 7.22%. The highest efficiency of 7.22% was obtained with an optimal spacer thickness of 40 μm.

  9. [Conservative anal fistula treatment with collagenic plug and human fibrin sealant. Preliminary results].

    Science.gov (United States)

    Gubitosi, A; Moccia, G; Malinconico, F A; Docimo, G; Ruggiero, R; Iside, G; Avenia, N; Docimo, L; Foroni, F; Gilio, F; Sparavigna, L; Agresti, M

    2009-01-01

    The authors, on the basis of a long clinical experience with human fibrin glue in general surgery, compared two different extracellular matrix (collagen), Surgisis and TissueDura, with human fibrin glue, applied during the operation, and sometimes in postoperative, to obtain the healing of perianal fistulas. The collagenic extracellular matrix provides, according to the rationale suggested, an optimal three-dimensional structure for the fibroblastic implant and neoangiogenesis, hence for the fistula "fibrotizzation" and closure. The encouraging results for transphincteric fistulas and a simple and easy technique push to researchers on samples statistically significant.

  10. Clinical study of the marginal microfiltration in restorations with amalgam applying sealant cavitario

    OpenAIRE

    Lahoud Salem, Víctor; Mendoza Zapata, Janet; Vidal Goñi, Raúl

    2014-01-01

    The present study to evaluate the clinical evaluation, marginal leakage of 30 amalgams restorations with sealers cavity and 30 amalgams restorations not sealers cavity. After of 12 months observation in amalgams restorations with sealers cavity 100% success in marginal leakage and not presents of secondary caries, not to have presents clinical cases of sensitivity post-operative and pulp inflammation. El presente estudio consistió en evaluar clínicamente la microfiltración marginal en 30 r...

  11. Economic modeling of sealing primary molars using a "value of information" approach.

    Science.gov (United States)

    Ney, J P; van der Goes, D N; Chi, D L

    2014-09-01

    The objective was to evaluate 2 primary molar sealant strategies for publicly insured children using an "expected value of perfect information" (EVPI) approach. We converted a 10,000-observation tooth-level cost-effectiveness simulation model comparing 2 primary molar sealant strategies - always seal (AS) and standard care (SC) - with a 1,250-observation child-level model. Costs per child per restoration or extraction averted were estimated. Opportunity losses under the AS strategy were determined for children for whom SC was the optimal choice. We determined the EVPI by multiplying mean opportunity losses by the projected incident population of publicly insured 3-year-olds in the US over 10 years with costs discounted at 2%. All analyses were conducted under assumptions of high and low intrachild correlations between at-risk teeth. The AS strategy cost $43.68 over SC (95% CI: -$5.50, $92.86) per child per restoration or extraction averted under the high intrachild correlation assumption and $15.54 (95% CI $7.86, $23.20) under the low intrachild correlation. Under high intrachild correlation, mean opportunity losses were $80.28 (95% CI: $76.39, $84.17) per child, and AS was the optimal strategy in 31% of children. Under low correlation, mean opportunity losses were $14.61 (95% CI: $12.20, $17.68) and AS was the optimal strategy in 87% of children. The EVPI was calculated at $530,813,740 and $96,578,389 (for high and low intrachild correlation, respectively), for a projected total incident population of 8,059,712 children. On average, always sealing primary molars is more effective than standard care, but widespread implementation of this preventive approach among publicly insured children would result in large opportunity losses. Additional research is needed to identify the subgroups of publicly insured children who would benefit the most from this effective and potentially cost-saving public health intervention. © International & American Associations for Dental

  12. Nanotechnology strategies for antibacterial and remineralizing composites and adhesives to tackle dental caries.

    Science.gov (United States)

    Cheng, Lei; Zhang, Ke; Weir, Michael D; Melo, Mary Anne S; Zhou, Xuedong; Xu, Hockin H K

    2015-03-01

    Dental caries is the most widespread disease and an economic burden. Nanotechnology is promising to inhibit caries by controlling biofilm acids and enhancing remineralization. Nanoparticles of silver were incorporated into composites/adhesives, along with quaternary ammonium methacrylates (QAMs), to combat biofilms. Nanoparticles of amorphous calcium phosphate (NACP) released calcium/phosphate ions, remineralized tooth-lesions and neutralized acids. By combining nanoparticles of silver/QAM/NACP, a new class of composites and adhesives with antibacterial and remineralization double benefits was developed. Various other nanoparticles including metal and oxide nanoparticles such as ZnO and TiO2, as well as polyethylenimine nanoparticles and their antibacterial capabilities in dental resins were also reviewed. These nanoparticles are promising for incorporation into dental composites/cements/sealants/bases/liners/adhesives. Therefore, nanotechnology has potential to significantly improve restorative and preventive dentistry.

  13. Preclinical characterization and safety of a novel hydrogel for augmenting dural repair

    International Nuclear Information System (INIS)

    Strong, Michael J; Carnahan, Michael A; D’Alessio, Keith; Butlin, Jared D G; Butt, Mark T; Asher, Anthony L

    2015-01-01

    Cerebrospinal fluid (CSF) leakage is a potentially serious complication in surgical procedures involving opening of the dura mater. Although several materials have been developed to help achieve watertight dural closures, CSF leakages persist. The goal of this study was to evaluate the performance of a novel hydrogel designed to provide augmentation to standard methods of dural repair. Performance measures such as polymerization time, dimensional swelling, burst strength, and elasticity were examined in laboratory situations. Additionally, biocompatibility in an in vivo rat model was examined. The results demonstrate that this novel hydrogel has superior mechanical strength and tissue adherence with enhanced flexibility, reduced swelling, and quicker set time compared with existing hydrogel dural sealants approved for intra-cranial use. Furthermore, biocompatibility studies demonstrate that this compound is both non-toxic and non-immunogenic. (paper)

  14. Bisphenol A (BPA) in China: a review of sources, environmental levels, and potential human health impacts.

    Science.gov (United States)

    Huang, Y Q; Wong, C K C; Zheng, J S; Bouwman, H; Barra, R; Wahlström, B; Neretin, L; Wong, M H

    2012-07-01

    Bisphenol A (BPA), identified as an endocrine disruptor, is an industrially important chemical that is used as a raw material in the manufacture of many products such as engineering plastics (e.g., epoxy resins/polycarbonate plastics), food cans (i.e., lacquer coatings), and dental composites/sealants. The demand and production capacity of BPA in China have grown rapidly. This trend will lead to much more BPA contamination in the environmental media and in the general population in China. This paper reviews the current literature concerning the pollution status of BPA in China (the mainland, Hong Kong, and Taiwan) and its potential impact on human health. Due to potential human health risks from long-term exposure to BPA, body burden of the contaminant should be monitored. Copyright © 2011 Elsevier Ltd. All rights reserved.

  15. Assessment of the efficacy of second life, a virtual learning environment, in dental education.

    Science.gov (United States)

    El Tantawi, Maha M A; El Kashlan, Mona K; Saeed, Yasmin M

    2013-12-01

    This study assessed the efficacy of Second Life (SL) in delivering lectures and demonstrating clinical procedures. Sixteen students in a dental school in Alexandria, Egypt, volunteered to participate in SL to learn about topical fluoride through lectures and YouTube videos demonstrating the application of fluoride gel. This was followed by face to face (F2F) sessions about pits and fissures sealant including lectures and F2F demonstration. Knowledge improvement was assessed by pre- and posttests; practical skills were assessed by a checklist; and percent scores were calculated. The relation between these scores and some background variables was assessed. Students' satisfaction with and perceptions of SL were also assessed. Knowledge improved significantly after both SL and F2F experiences (peducation institutions with problems of increasing numbers of students and limited space.

  16. Management of a complicated pulmonary fistula caused by lung cancer using a fibrin glue-soaked polyglycolic acid sheet covered with an intercostal muscle flap.

    Science.gov (United States)

    Maniwa, Tomohiro; Kaneda, Hiroyuki; Saito, Yukihito

    2009-06-01

    Pulmonary fistulas caused by tumours are very fragile and difficult to suture directly. It is impossible to close pulmonary fistulas with tissue sealants when massive air leakage occurs in the low pressure of the respiratory tract. A 73-year-old man with a pneumothorax caused by lung cancer had suffered a persistent massive air leakage for more than one month. We used a fibrin glue-soaked polyglycolic acid (PGA) sheet for sealing the complicated fistula. In addition, the visceral pleura of the fistula was wrapped with the pedicle of an intercostal muscle (ICM) flap to prevent massive air leakage. The pneumothorax did not reappear after surgery. Thus, a fibrin glue-soaked PGA sheet covered with an ICM flap was effective for sealing an intractable air-leaking fistula caused by lung cancer.

  17. Bio-artificial pleura using an autologous dermal fibroblast sheet

    Science.gov (United States)

    Kanzaki, Masato; Takagi, Ryo; Washio, Kaoru; Kokubo, Mami; Yamato, Masayuki

    2017-10-01

    Air leaks (ALs) are observed after pulmonary resections, and without proper treatment, can produce severe complications. AL prevention is a critical objective for managing patients after pulmonary resection. This study applied autologous dermal fibroblast sheets (DFS) to close ALs. For sealing ALs in a 44-year-old male human patient with multiple bullae, a 5 × 15-mm section of skin was surgically excised. From this skin specimen, primary dermal fibroblasts were isolated and cultured for 4 weeks to produce DFSs that were harvested after a 10-day culture. ALs were completely sealed using surgical placement of these autologous DFSs. DFS were found to be a durable long-term AL sealant, exhibiting requisite flexibility, elasticity, durability, biocompatibility, and usability, resulting reliable AL closure. DFS should prove to be an extremely useful tissue-engineered pleura substitute.

  18. Tribology and Microstructure of PS212 with a Cr2O3 Seal Coat

    Science.gov (United States)

    Sliney, Harold E.; Benoy, Patricia A.; Korenyi-Both, Andras; Dellacorte, Christopher

    1994-01-01

    PS212 is a plasma sprayed metal bonding chrome carbide coating with solid lubricant additives which has lubricating properties at temperatures up to about 900 deg C. The coating is diamond ground to achieve an acceptable tribological surface. But, as with many plasma spray coatings, PS212 is not fully-dense. In this study, a chromium oxide base seal coating is used in an attempt to seal any porosity that is open to the surface of the PS212 coating, and to study the effect of the sealant on the tribological properties of PS212. The results indicate that the seal coating reduces friction and wear when it is applied and then diamond ground leaving a thin layer of seal coating which fills in the surface pits of the PS212 coating.

  19. Feasibility of using neutron radiography to inspect the Space Shuttle solid rocket booster aft skirt, forward skirt and frustum. Part 1: Summary report

    Science.gov (United States)

    Barton, J. P.; Bader, J. W.; Brenizer, J. S.; Hosticka, B.

    1992-01-01

    The space shuttle's solid rocket boosters (SRB) include components made primarily of aluminum that are parachuted back for retrieval from the ocean and refurbished for repeated usage. Nondestructive inspection methods used on these aging parts to reduce the risk of unforeseen problems include x-ray, ultrasonics, and eddy current. Neutron radiography tests on segments of an SRB component show that entrapped moisture and naturally occurring aluminum corrosion can be revealed by neutron radiography even if present in only small amounts. Voids in sealant can also be evaluated. Three alternatives are suggested to follow-up this study: (1) take an SRB component to an existing neutron radiography system; (2) take an existing mobile neutron radiography system to the NASA site; or (3) plan a dedicated system custom designed for NASA applications.

  20. Electroremediation of PCB contaminated soil combined with iron nanoparticles: Effect of the soil type

    DEFF Research Database (Denmark)

    Gomes, Helena I.; Dias-Ferreira, Celia; Ottosen, Lisbeth M.

    2015-01-01

    Polychlorinated biphenyls (PCB) are carcinogenic and persistent organic pollutants that accumulate in soils and sediments. Currently, there is no cost-effective and sustainable remediation technology for these contaminants. In this work, a new combination of electrodialytic remediation and zero...... nanoparticles. Remediation experiments are made with two different historically PCB contaminated soils, which differ in both soil composition and contamination source. Soil 1 is a mix of soils with spills of transformer oils, while Soil 2 is a superficial soil from a decommissioned school where PCB were used...... as windows sealants. Saponin, a natural surfactant, was also tested to increase the PCB desorption from soils and enhance dechlorination. Remediation of Soil 1 (with highest pH, carbonate content, organic matter and PCB concentrations) obtained the maximum 83% and 60% PCB removal with the two...

  1. Mechanical Behaviour of Glassy Composite Seals for IT-SOFC Application

    DEFF Research Database (Denmark)

    Nielsen, Karsten Agersted; Solvang, Mette; Nielsen, Sofie Birkedal Lund

    2007-01-01

    Glass-based sealants have been developed with emphasis on filler material and surface treatment of the sealing components in order to optimise their mechanical and functional behaviour during the initial sealing process as well as during thermal cycling of the SOFC-stack after exposure to operating...... conditions. The bonding strength and microstructure of the interfaces between composite seals and interconnect materials were investigated as a function of surface treatment of the sealing surfaces, glass matrix composition, sealing pressure and temperature. The initial sealing performance and resistance...... to thermal cycling were then investigated on selected combinations of materials after ageing. Strongest bonding between sodium aluminosilicate glass composite and steel surfaces was obtained for sealing at 850°C. For the strongest interface, having shear strength of 2.35 MPa, rupture occurred in the glass...

  2. Nanotechnology strategies for antibacterial and remineralizing composites and adhesives to tackle dental caries

    Science.gov (United States)

    Cheng, Lei; Zhang, Ke; Weir, Michael D; Melo, Mary Anne S; Zhou, Xuedong; Xu, Hockin HK

    2015-01-01

    Dental caries is the most widespread disease and an economic burden. Nanotechnology is promising to inhibit caries by controlling biofilm acids and enhancing remineralization. Nanoparticles of silver were incorporated into composites/adhesives, along with quaternary ammonium methacrylates (QAMs), to combat biofilms. Nanoparticles of amorphous calcium phosphate (NACP) released calcium/phosphate ions, remineralized tooth-lesions and neutralized acids. By combining NAg/QAM/NACP, a new class of composites and adhesives with antibacterial and remineralization double benefits was developed. Various other nanoparticles including metal and oxide nanoparticles such as ZnO and TiO2, as well as polyethylenimine nanoparticles and their antibacterial capabilities in dental resins were also reviewed. These nanoparticles are promising for incorporation into dental composites/cements/sealants/bases/liners/adhesives. Therefore, nanotechnology has potential to significantly improve restorative and preventive dentistry. PMID:25723095

  3. Demonstration and Validation of a High-Performance Floor-Sealant System to Reduce Concrete Degradation

    Science.gov (United States)

    2015-05-01

    1 Recycled Antifreeze 01-197-7692 MIL-PRF-10924H GAA Grease 01-102-9455 MIL-PRF-46176B Brake Fluid 00-252-6383 MIL-PRF-5606H Hydraulic Fluid H515...contaminated clothing , clean thoroughly before reuse. Inhalation: Move to fresh air. If not breathing, give rescue breathing. I f breathing is...material to absorb the spill, use plastic shovel to pick up absorbent for disposal Spills and Leaks: Dispose in accordance to local, state or federal

  4. SST Technology Follow-On Program-Phase 2. Development and Evaluation of Fuel Tank Sealants

    Science.gov (United States)

    1975-12-15

    DC 77-0,2. Tuday it is marketed as DC 94-529. Dow Corning and Boeing wocked closely together to develop the fluoros:licone system with the emphasis...FOLLO.WI& A-DADS: Tog&UNW PAINKL&- D15PTH NLINE ~~~6 W1I~ A IT II _ _ _ _ _ _ _ _ _ _ _ _-Pag_ II W 6I PrI’ I,% I. I I Ix. £~l T 3T 0 F11: s~ir

  5. Infant oral health care: An invaluable clinical intervention

    Directory of Open Access Journals (Sweden)

    Kanika Singh Dhull

    2016-01-01

    Full Text Available Dental assessments and evaluations for children during their 1st year of life have been recommended by the American Academy of Pediatric Dentistry and the American Association of Pediatrics. Early dental intervention evaluates a child's risk status based on parental interviews and oral examinations. These early screenings present an opportunity to educate parents about the medical, dental, and cost benefits of preventive rather than restorative care and may be more effective in reducing early childhood caries than traditional infectious disease models. A comprehensive infant oral care program includes: (1 risk assessments at regularly scheduled dental visits, (2 preventive treatments such as fluoride varnishes or sealants, (3 parental education on the correct methods to clean the baby's mouth, and (4 establishment of dental home and use of anticipatory guidance. The present article highlights the important guidelines of infant oral health care.

  6. Nanoparticle amount, and not size, determines chain alignment and nonlinear hardening in polymer nanocomposites

    Science.gov (United States)

    Varol, H. Samet; Meng, Fanlong; Hosseinkhani, Babak; Malm, Christian; Bonn, Daniel; Bonn, Mischa; Zaccone, Alessio

    2017-01-01

    Polymer nanocomposites—materials in which a polymer matrix is blended with nanoparticles (or fillers)—strengthen under sufficiently large strains. Such strain hardening is critical to their function, especially for materials that bear large cyclic loads such as car tires or bearing sealants. Although the reinforcement (i.e., the increase in the linear elasticity) by the addition of filler particles is phenomenologically understood, considerably less is known about strain hardening (the nonlinear elasticity). Here, we elucidate the molecular origin of strain hardening using uniaxial tensile loading, microspectroscopy of polymer chain alignment, and theory. The strain-hardening behavior and chain alignment are found to depend on the volume fraction, but not on the size of nanofillers. This contrasts with reinforcement, which depends on both volume fraction and size of nanofillers, potentially allowing linear and nonlinear elasticity of nanocomposites to be tuned independently. PMID:28377517

  7. Assessment of pre-fabricated bathrooms from the 1990s

    DEFF Research Database (Denmark)

    Morelli, Martin; Brandt, Erik

    2015-01-01

    -weight assembly kit with fibre reinforced concrete bottoms - Light-weight assembly kit of fibre reinforced concrete elements The use of an inspection scheme implied that a consistent visual assessment of the bathrooms included constructions, installations and measurable conditions, e.g. moisture content and crack...... sizes, was obtained. Each parameter in the inspection scheme was judged on a 5 step ranking scale of conditions and interrelated degree of consequences. The investigation of the 9 bathrooms indicated a generally high quality of the bathrooms. Many of the registered failures may be eliminated...... with increased maintenance. Specifically, mould growth on resilient silicone sealant was a problem in wet zones. More critically was the registered mould growth in the ceiling, where the mechanical ventilation was low. Both issues could to some degree be prevented by more focus on user habits and maintenance...

  8. Conceptual design report for the project to install leak detection in FAST-FT-534/548/549

    Energy Technology Data Exchange (ETDEWEB)

    Galloway, K.J.

    1992-07-01

    This report provides conceptual designs and design recommendations for installing secondary containment and leak detection systems for three sumps at the Fluorinel and Storage Facility (FAST), CPP-666. The FAST facility is located at the Idaho Chemical Processing Plant (ICPP) at the Idaho National Engineering Laboratory (INEL). The three sumps receive various materials from the FAST water treatment process. This project involves sump upgrades to meet appropriate environmental requirements. The steps include: providing sump modifications or designs for the installation of leak chases and/or leakage accumulation, coating the sump concrete with a chemical resistant sealant (except for sump VES-FT-534 which is already lined with stainless steel) to act as secondary containment, lining the sumps with a primary containment system, and providing a means to detect and remove primary containment leakage that may occur.

  9. Sealable joint steel sheet piling for groundwater control and remediation: Case histories

    International Nuclear Information System (INIS)

    Smyth, D.; Jowett, R.; Gamble, M.

    1997-01-01

    The Waterloo Barrier trademark steel sheet piling (patents pending) incorporates a cavity at each interlocking joint that is flushed clean and injected with sealant after the piles have been driven into the ground to form a vertical cutoff wall. The installation and sealing procedures allow for a high degree of quality assurance and control. Bulk wall hydraulic conductivities of 10 -8 to 10 -10 cm/sec have been demonstrated at field installations. Recent case histories are presented in which Waterloo Barrier trademark cutoff walls are used to prevent off-site migration of contaminated groundwater or soil gases to adjacent property and waterways. Full enclosures to isolate DNAPL source zones or portions of contaminated aquifers for pilot-scale remediation testing will also be described. Monitoring data will be used to demonstrate the effectiveness of the Waterloo Barrier trademark in these applications

  10. Recent Advances in Glycerol Polymers: Chemistry and Biomedical Applications

    Science.gov (United States)

    Zhang, Heng

    2015-01-01

    Glycerol polymers are attracting increased attention due to the diversity of polymer compositions and architectures available. This article provides a brief chronological review on the current status of these polymers along with representative examples of their use for biomedical applications. First, we describe the underlying chemistry of glycerol, which provides access to a range of monomers for subsequent polymerizations. We then review the various synthetic methodologies to prepare glycerol-based polymers including polyethers, polycarbonates, polyesters, and so forth. Next, we describe several biomedical applications where glycerol polymers are being investigated including carriers for drug delivery, sealants or coatings for tissue repair, and agents possessing antibacterial activity. Fourth, we describe the growing market opportunity for the use of polymers in medicine. Finally we conclude and summarize the findings, as well as discuss potential opportunities for continued research efforts. PMID:25308354

  11. Conceptual design report for the project to install leak detection in FAST-FT-534/548/549

    International Nuclear Information System (INIS)

    Galloway, K.J.

    1992-07-01

    This report provides conceptual designs and design recommendations for installing secondary containment and leak detection systems for three sumps at the Fluorinel and Storage Facility (FAST), CPP-666. The FAST facility is located at the Idaho Chemical Processing Plant (ICPP) at the Idaho National Engineering Laboratory (INEL). The three sumps receive various materials from the FAST water treatment process. This project involves sump upgrades to meet appropriate environmental requirements. The steps include: providing sump modifications or designs for the installation of leak chases and/or leakage accumulation, coating the sump concrete with a chemical resistant sealant (except for sump VES-FT-534 which is already lined with stainless steel) to act as secondary containment, lining the sumps with a primary containment system, and providing a means to detect and remove primary containment leakage that may occur

  12. Cost evaluation of two methods of post tooth extraction hemostasis in patients on anticoagulant therapy.

    Science.gov (United States)

    Zusman, S P; Lustig, J P; Bin Nun, G

    1993-06-01

    The classical management of patients on oral anticoagulant therapy included hospitalisation, cessation of the anticoagulant agent, and extraction of teeth when the prothrombine levels rise. This method was substituted in the High Risk Dental Clinic at Barzilai Medical Center in Ashkelon by use of a tissue sealant (Tisseel) which does not need hospitalisation nor cessation of the anticoagulant therapy. In comparing the last 23 sessions employing the former method to the first 23 sessions using the new method there were significant differences in the cost effectiveness for the health system, provider, insurer and patient. Despite the fact that from the health system point of view the new method is much more cost effective, there is no financial incentive for the provider (hospital) nor awareness on the part of the insurer (General Sick Fund) to embrace it and 'market' it.

  13. Development of Osaka gas type planar SOFC

    Energy Technology Data Exchange (ETDEWEB)

    Iha, M.; Shiratori, A.; Chikagawa, O. [Murata Mfg. Co., Ltd., Shiga (Japan)] [and others

    1996-12-31

    Osaka Gas Co. has been developing a planar type SOFC (OG type SOFC) which has a suitable structure for stacking. Murata Mfg. Co. has begun to develop the OG type SOFC stack through joint program since 1993. Figure 1 shows OG type cell structure. Because each cell is sustained by cell holders acting air manifold, the load of upper cell is not put on the lower cells. Single cell is composed of 3-layered membrane and LaCrO{sub 3} separator. 5 single cells are mounted on the cell holder, connected with Ni felt electrically, and bonded by glassy material sealant. We call the 5-cell stack a unit. Stacking 13 units, we succeeded 870 W generation in 1993. But the power density was low, 0.11 Wcm{sup -2} because of crack in the electrolyte and gas leakage at some cells.

  14. Characterization of Emissions from Building Products: Selection Criteria, Storage and Handling of Indoor Materials for Experiments

    DEFF Research Database (Denmark)

    Kjær, Ulla Dorte; Nielsen, Peter A.; Marcussen, Lis

    1996-01-01

    In research projects it is usually impossible to study more than a very limited aount of different products. Care and consideration must therefore be taken in the selection. The following criteria were used to select five products for chemical and sensory emission testing: The products should...... be indoor climate relevant, meaning that they should be in direct contact with indoor air when used in buildings, and their emission should contribute significantly to the indoor air concentrations for instance due to a large surface area. They should be representative in terms of being widely used, now...... that the emission mechanisms do not change as a consequence of physical processes or chemical reactions. The five products selected were PVC flooring, waterborne varnish on beechwood parquet, carpet, sealant, and waterborne paint on gypsum board. The products were brought to the laboratory immediately after...

  15. Passive solar construction handbook

    Energy Technology Data Exchange (ETDEWEB)

    Levy, E.; Evans, D.; Gardstein, C.

    1981-08-01

    Many of the basic elements of passive solar design are reviewed. The unique design constraints presented in passive homes are introduced and many of the salient issues influencing design decisions are described briefly. Passive solar construction is described for each passive system type: direct gain, thermal storage wall, attached sunspace, thermal storage roof, and convective loop. For each system type, important design and construction issues are discussed and case studies illustrating designed and built examples of the system type are presented. Construction details are given and construction and thermal performance information is given for the materials used in collector components, storage components, and control components. Included are glazing materials, framing systems, caulking and sealants, concrete masonry, concrete, brick, shading, reflectors, and insulators. The Load Collector Ratio method for estimating passive system performance is appended, and other analysis methods are briefly summarized. (LEW)

  16. Molecular structure stability of short-chain chlorinated paraffins (SCCPs): Evidence from lattice compatibility and Simha-Somcynsky theories

    Science.gov (United States)

    Yumak, A.; Boubaker, K.; Petkova, P.; Yahsi, U.

    2015-10-01

    In is known that short-chain chlorinated paraffins (SCCPs) are highly complex technical mixtures of polychlorinated n-alkanes with single chlorine content. Due to their physical properties (viscosity, flame resistance) they are used in many different applications, such as lubricant additives, metal processing, leather fat-liquoring, plastics softening, PVC plasticizing and flame retardants in paints, adhesives and sealants. SCCPs are studied here in terms of processing-linked molecular structure stability, under Simha and Somcynsky-EOS theory calculations and elements from Simha-Somcynsky-related Lattice Compatibility Theory. Analyses were carried out on 1-chloropropane, 2-chloropropane, 1-chlorobutane, 2-chlorobutane, 1-chloro 2-methylane, and 2-chloro 2-methylane as (SCCPs) universal representatives. This paper gives evidence to this stability and reviews the current state of knowledge and highlights the need for further research in order to improve future (SCCPs) monitoring efforts.

  17. Regulatory Strategies To Minimize Generation Of Regulated Wastes From Cleanup, Continued Use Or Decommissioning Of Nuclear Facilities Contaminated With Polychlorinated Biphenyls (PCBS) - 11198

    International Nuclear Information System (INIS)

    Lowry, N.

    2010-01-01

    . Allowable options must be evaluated carefully in order to reduce compliance risks, protect personnel, limit potential negative impacts on facility operations, and minimize the generation of wastes subject to TSCA. This paper will identify critical factors in selecting the appropriate TSCA regulatory path in order to minimize the generation of radioactive PCB waste and reduce negative impacts to facilities. The importance of communicating pertinent technical issues with facility staff, regulatory personnel, and subsequently, the public, will be discussed. Key points will be illustrated by examples from five former production reactors at the DOE Savannah River Site. In these reactors a polyurethane sealant was used to seal piping penetrations in the biological shield walls. During the intense neutron bombardment that occurred during reactor operation, the sealant broke down into a thick, viscous material that seeped out of the piping penetrations over adjacent equipment and walls. Some of the walls were painted with a PCB product. PCBs from the paint migrated into the degraded sealant, creating PCB 'spill areas' in some of these facilities. The regulatory cleanup approach selected for each facility was based on its operational status, e.g., active, inactive or undergoing decommissioning. The selected strategies served to greatly minimize the generation of radioactive liquid PCB waste. It is expected that this information would be useful to other DOE sites, DOD facilities, and commercial nuclear facilities constructed prior to the 1979 TSCA ban on most manufacturing and uses of PCBs.

  18. Curing of polymer thermosets via click reactions and on demand processes

    Science.gov (United States)

    Brei, Mark Richard

    In the first project, an azide functional resin and tetra propargyl aromatic diamines were fabricated for use as a composite matrix. These systems take already established epoxy/amine matrices and functionalize them with click moieties. This allows lower temperatures to be used in the production of a thermoset part. These new systems yield many better mechanical properties than their epoxy/amine derivatives, but their Tgs are low in comparison. The second project investigates the characterization of a linear system based off of the above azide functional resin and a difunctional alkyne. Through selectively choosing catalyst, the linear system can show regioselectivity to either a 1,4-disubstituted triazole, or a 1,5-disubstituted triazole. Without the addition of catalyst, the system produces both triazoles in almost an equal ratio. The differently catalyzed systems were cured and then analyzed by 1H and 13C NMR to better understand the structure of the material. The third project builds off of the utility of the aforementioned azide/alkyne system and introduces an on-demand aspect to the curing of the thermoset. With the inclusion of copper(II) within the azide/alkyne system, UV light is able to catalyze said reaction and cure the material. It has been shown that the copper(II) loading levels can be extremely small, which helps in reducing the copper's effect on mechanical properties The fourth project takes a look at polysulfide-based sealants. These sealants are normally cured via an oxidative reaction. This project took thiol-terminated polysulfides and fabricated alkene-terminated polysulfides for use as a thiol-ene cured material. By changing the mechanism for cure, the polysulfide can be cured via UV light with the use of a photoinitiator within the thiol/alkene polysulfide matrix. The final chapter will focus on a characterization technique, MALDI-TOF, which was used to help characterize the above materials as well as many others. By using MALDI-TOF, the

  19. Performance Evaluation and Durability Studies of Adhesive Bonds

    Science.gov (United States)

    Ranade, Shantanu Rajendra

    into the long-term performance of silicone sealants designed for load-bearing applications such as solar panel support sealants. Using small strain constitutive tests and time-temperature-superposition principle, thermal shift factors were obtained and successfully used to characterize the creep rupture master curves for specific joint configurations, leading to insights into delayed failures corresponding to three years through experiments carried out in one month.

  20. Vivostat®: an autologous fibrin sealant as useful adjunct in endoscopic transnasal CSF-leak repair.

    Science.gov (United States)

    Tomazic, Peter Valentin; Edlinger, Stefan; Gellner, Verena; Koele, Wolfgang; Gerstenberger, Claus; Braun, Hannes; Mokry, Michael; Stammberger, Heinz

    2015-06-01

    The benefit of fibrin glue for reduction of postoperative CSF-leaks after endoscopic skull base surgery is not clearly evident in literature. However, its use is supposed to be beneficial in fixing grafting material. As of today there is no specific data available for otolaryngological procedures. A retrospective data analysis at a tertiary care referral center on 73 patients treated endoscopically transnasally for CSF-leaks at the ENT-department Graz between 2009 and 2012 was performed. Primary closure rate between conventional fibrin glue and autologous fibrin glue were analyzed. The Vivostat(®) system was used in 33 CSF-leak closures and in 40 cases conventional fibrin glue was used. Comparing the two methods the primary closure rate using the autologous Vivostat(®) system was 75.8 and 85.0 % with conventional fibrin glue. The secondary closure the rates were 90.9 % with Vivostat(®) 92.5 % with conventional fibrin glue. The Vivosat(®) system is a useful adjunct in endoscopic CSF-leak closure. Its advantages over conventional fibrin glue are its application system for fixation of grafting material particularly in underlay techniques. Despite this advantage it cannot replace grafting material or is a substitute for proper endoscopic closure which is reflected by the closure rates.

  1. Low-cost glass ionomer cement as ART sealant in permanent molars: a randomized clinical trial

    NARCIS (Netherlands)

    Hesse, D.; Bonifácio, C.C.; Guglielmi, C. de Almeida Brandao; da Franca, C.; Mendes, F.M.; Raggio, D.P.

    2015-01-01

    Clinical trials are normally performed with well-known brands of glass ionomer cement (GIC), but the cost of these materials is high for public healthcare in less-affluent communities. Given the need to research cheaper materials, it seems pertinent to investigate the retention rate of a low-cost

  2. Chemistry Division progress report for the period January 1, 1977 - December 31, 1980

    International Nuclear Information System (INIS)

    Moorthy, P.N.; Ramshesh, V.; Yakhmi, J.V.

    1981-01-01

    The research and development work of the Chemistry Division of the Bhabha Atomic Research Centre, Bombay, during the period 1977-1980 is reported in the form of individual summaries under the headings: basic research including radiation chemistry, photochemistry, kinetic and electrochemical studies, ion exchange and sorption behaviour, chemistry of metal complexes (in particular, of uranium complexes), radiation damage in solids, heterogeneous catalysts, studies in magnetism, physical properties, solid state studies, theoretical studies, reactor related programmes (including reactor chemistry, lubricants and sealants, surface studies, water chemistry), applied research and development (including materials development, purification and analytical techniques, apolied radiation chemistry etc.), and instrumentation. Work of service facilities such as workshop, analytical se services, and repair and maintenance of instruments is described. Lists of training programmes, staff publications and divisional seminars, are given. At the end a sectionwise list of staff members is also given. (M.G.B.)

  3. Effect of bar sealing parameters on OPP/MCPP heat seal strength

    Directory of Open Access Journals (Sweden)

    2007-11-01

    Full Text Available The effect of bar sealing parameters on the heat seal strength of oriented polypropylene (OPP/metallic cast polypropylene (MCPP laminate film was investigated. Based on the results obtained from the parametric study, a bar sealing process window was developed. All points drop within the process window are combinations of platen temperature and dwell time that produce acceptable heat seal. Optimum combinations are indicated by the lower border of the window. The plateau initiation temperature, Tpi of OPP/MCPP laminate film used in the present study occurred before the final melting temperature, Tmf of the sealant material. The highest achievable heat seal strength was at the plateau region, and the corresponding failure modes were delaminating, tearing or combine failure modes (delaminating and tearing. Minimum pressure level of 1.25 bars is necessary to bring the laminate interface into intimate contact in order to effect sealing.

  4. Development of high performance drilling fluids from national products: part I; Desenvolvimento de fluidos de perfuracao de alto desempenho a partir de produtos nacionais: parte I

    Energy Technology Data Exchange (ETDEWEB)

    Farias, Kassie V.; Amorim, Luciana V. [Universidade Federal de Campina Grande (UFCG), PB (Brazil); Agencia Nacional do Petroleo (ANP), Brasilia, DF (Brazil). Programa de Recursos Humanos; Lira, Helio L. [Universidade Federal de Campina Grande (UFCG), PB (Brazil). Unidade Academica de Engenharia de Materiais

    2008-07-01

    This work has a main objective to develop formulations of high performance water-based drilling fluids composed of national additives and evaluate their rheologic, filtration and lubrication behavior. It was developed ten formulations containing the following additives: viscosity, filtered reducer, controlling of pH, hydra table clays inhibitors, anti foamy, bactericide, lubricant and sealant. The fluids were prepared according to the field practice that consists of adding to water the additives under constant agitation. After 24 h resting, it was carried out a study of the rheologic behavior, in a Fann 35 A viscosimeter, and of the filtration properties in a Fann press-filter and of lubricity in a Ofite lubricimeter through the determination of the flow curves, apparent and plastic viscosities, yield limit, gel force, filtered volume, filter-cake thickness and lubricity coefficient. The results obtained were very promising, with properties close to the standard. (author)

  5. Pentachlorophenol measurements in body fluids of people in log homes and workplaces

    Energy Technology Data Exchange (ETDEWEB)

    Cline, R.E.; Hill, R.H. Jr.; Phillips, D.L.; Needham, L.L.

    1989-07-01

    Human exposure to pentachlorophenol (PCP) was evaluated in the normal population (controls), residents of PCP-treated log homes, and persons exposed primarily in the workplace. Blood and urine samples were analyzed by gas chromatography after extraction and acetylation. For 34 controls, serum PCP values ranged from 15-75 ppb with a mean of 40 ppb. For 123 residents of log homes, serum levels ranged from 69-1,340 ppb with a mean of 420 ppb. In such homes, serum levels for children were significantly higher than those for parents, averaging 1.8 times greater. Serum and urine values for workers varied widely, depending on the workplace, with serum levels ranging from 26 to 84,900 ppb of PCP. Urinary concentrations when corrected for creatinine values correlated well (r = 0.92) with serum concentrations. Coating PCP-treated logs of home interiors with a sealant reduced serum PCP levels in the residents.

  6. Site-Specific Research Conducted in Support of the Salton Sea Solar Pond Project - FY 1982 Report

    Science.gov (United States)

    French, R. L.; Marsh, H. E.; Roschke, E. J.; Wu, Y. C.

    1984-01-01

    The design and operation of a salt-gradient solar pond power plant at the Salton Sea presents problems not encountered at small research ponds that were built in the United States. The specific characteristics of the Salton Sea site and the desire to construct the pond using the local clay as a sealant represent major deviations from previous solar pond experience. The site-specific research in support of the plant design is described. The research activity included validation of the spectrophotometric light transmission measurement technique, a search for options for clarifying the turbid and colored water of the Salton Sea, development of water clarification specifications in terms common to industry practice, quantification of gas production from microbiological reactions in the ground, a determination of the combined effects of temperature and salinity on the permeation of the local clays, and a preliminary evaluation of material corrosion.

  7. SOLID STATE ENERGY CONVERSION ALLIANCE (SECA) SOLID OXIDE FUEL CELL PROGRAM

    Energy Technology Data Exchange (ETDEWEB)

    Nguyen Minh; Jim Powers

    2003-10-01

    This report summarizes the work performed for April 2003--September 2003 reporting period under Cooperative Agreement DE-FC26-01NT41245 for the U.S. Department of Energy, National Energy Technology Laboratory (DOE/NETL) entitled ''Solid State Energy Conversion Alliance (SECA) Solid oxide Fuel Cell Program''. During this reporting period, the conceptual system design activity was completed. The system design, including strategies for startup, normal operation and shutdown, was defined. Sealant and stack materials for the solid oxide fuel cell (SOFC) stack were identified which are capable of meeting the thermal cycling and degradation requirements. A cell module was tested which achieved a stable performance of 0.238 W/cm{sup 2} at 95% fuel utilization. The external fuel processor design was completed and fabrication begun. Several other advances were made on various aspects of the SOFC system, which are detailed in this report.

  8. Aging management program of the reactor building concrete at Point Lepreau Generating Station

    Science.gov (United States)

    Aldea, C.-M.; Shenton, B.; Demerchant, M. M.; Gendron, T.

    2011-04-01

    In order for New Brunswick Power Nuclear (NBPN) to control the risks of degradation of the concrete reactor building at the Point Lepreau Generating Station (PLGS) the development of an aging management plan (AMP) was initiated. The intention of this plan was to determine the requirements for specific structural components of concrete of the reactor building that require regular inspection and maintenance to ensure the safe and reliable operation of the plant. The document is currently in draft form and presents an integrated methodology for the application of an AMP for the concrete of the reactor building. The current AMP addresses the reactor building structure and various components, such as joint sealant and liners that are integral to the structure. It does not include internal components housed within the structure. This paper provides background information regarding the document developed and the strategy developed to manage potential degradation of the concrete of the reactor building, as well as specific programs and preventive and corrective maintenance activities initiated.

  9. Influence of different functionalization on mechanical and interface behavior of MWCNTs/NBR sealing composites

    Science.gov (United States)

    Li, Kun; Gu, Boqin

    2017-04-01

    Rubber sealants are key components in processing industries. Carbon nanotubes (CNTs), which are randomly dispersed in polymer, are able to generate exciting effects. Focusing on mechanical properties of composites and interface characteristic between the fillers and matrix, carrying out SEM, DMA and uniaxial tensile tests, the tensile strength of the composites with 4 phr (parts by weight per hundred parts of rubber) multiwalled carbon nanotubes (MWNTs) is obviously improved. MWNTs with different functionalization have different influence on the viscoelastic and mechanical properties of the composites. Results indicate that MWNTs-COOH are broken when composites fractured. While MWNTs, MWNTs-OH and MWNTs-NH2 are pulled out from the matrix because interface debonds under the tensile failure. The interfacial shear stress (IFSS) is about 4.7 MPa in composites. The glass transition temperature (T g) shifts higher temperatures compared to pure NBR (Acrylonitrile-butadiene Rubber). The presence of the nanotubes limite the movement of NBR macromolecules.

  10. Microbial healing of cracks in concrete: a review.

    Science.gov (United States)

    Joshi, Sumit; Goyal, Shweta; Mukherjee, Abhijit; Reddy, M Sudhakara

    2017-11-01

    Concrete is the most widely used construction material of the world and maintaining concrete structures from premature deterioration is proving to be a great challenge. Early age formation of micro-cracking in concrete structure severely affects the serviceability leading to high cost of maintenance. Apart from conventional methods of repairing cracks with sealants or treating the concrete with adhesive chemicals to prevent the cracks from widening, a microbial crack-healing approach has shown promising results. The unique feature of the microbial system is that it enables self-healing of concrete. The effectiveness of microbially induced calcium carbonate precipitation (MICCP) in improving durability of cementitious building materials, restoration of stone monuments and soil bioclogging is discussed. Main emphasis has been laid on the potential of bacteria-based crack repair in concrete structure and the applications of different bacterial treatments to self-healing cracks. Furthermore, recommendations to employ the MICCP technology at commercial scale and reduction in the cost of application are provided in this review.

  11. Changing clinicians' behavior: a randomized controlled trial of fees and education.

    Science.gov (United States)

    Clarkson, J E; Turner, S; Grimshaw, J M; Ramsay, C R; Johnston, M; Scott, A; Bonetti, D; Tilley, C J; Maclennan, G; Ibbetson, R; Macpherson, L M D; Pitts, N B

    2008-07-01

    The fissure-sealing of newly erupted molars is an effective caries prevention treatment, but remains underutilized. Two plausible reasons are the financial disincentive produced by the dental remuneration system, and dentists' lack of awareness of evidence-based practice. The primary hypothesis was that implementation strategies based on remuneration or training in evidence-based healthcare would produce a higher proportion of children receiving sealed second permanent molars than standard care. The four study arms were: fee per sealant treatment, education in evidence-based practice, fee plus education, and control. A cost-effectiveness analysis was conducted. Analysis was based on 133 dentists and 2833 children. After adjustment for baseline differences, the primary outcome was 9.8% higher when a fee was offered. The education intervention had no statistically significant effect. 'Fee only' was the most cost-effective intervention. The study contributes to the incentives in health care provision debate, and led to the introduction of a direct fee for this treatment.

  12. Prevention and treatment of white spot lesions in orthodontic patients

    Directory of Open Access Journals (Sweden)

    Maryam Khoroushi

    2017-01-01

    Full Text Available Decalcification of enamel, appearing as white spot lesions (WSLs, around fixed orthodontic appliances is a major challenge during and after fixed orthodontic treatment by considering the fact that the goal of orthodontic treatment is to enhance facial and dental esthetic appearance. Banded or bonded teeth exhibit a significantly higher rate of WSLs compared to the controls with no braces as fixed appliances and the bonding materials promote retention of biofilms. These lesions are managed in the first step by establishing good oral hygiene habits and prophylaxis with topical fluorides, including high-fluoride toothpastes, fluoride mouthwashes, gels, varnishes, fluoride-containing bonding materials, and elastic ligatures. Recently, other materials and methods have been recommended, including the application of casein phosphopeptides-amorphous calcium phosphate, antiseptics, probiotics, polyols, sealants, laser, tooth bleaching agents, resin infiltration, and microabrasion. This article reviews the currently used methods to manage enamel demineralization during and after orthodontic treatment and the risk factors and preventive measures based on the latest evidence.

  13. Comparative Assessment of Stabilised Polybutadiene Binder under Accelerated Ageing

    Directory of Open Access Journals (Sweden)

    Luiz Felipe Cannaval Sbegue

    2016-04-01

    Full Text Available Polybutadiene elastomers are versatile materials, being employed at several applications from rocket propellant binder to adhesives and sealants. The elastomers derived from hydroxyl-terminated polybutadiene are usually stabilised with antioxidants to prevent degradation. In this study, a comparative assessment among 2,2’-methylene-bis (4-methyl-6-tert-butylphenol (AO2246, 2,6-di-tert-butyl-4-methylphenol (BHT, p-phenylenediamine (pPDA, and triphenylphosphine (TPP regarding stabilisation of hydroxyl-terminated polybutadiene binder under accelerated ageing (six months at 65 °C was carried out. Evaluation of antioxidants effectiveness was examined through Oxidation Induction time, sol/gel extraction, swelling and mechanical testing, dynamic mechanical analysis, and mass variation measurement. AO2246 yielded the best performance, meanwhile BHT was poorly protective. TPP acted as prooxidant, causing a severe degradation of the binder, and pPDA was not manageable to be assessed due to the lower curing degree of the resulted polyurethane.

  14. In vitro effects of alcohol-containing and alcohol-free mouthrinses on microhardness of some restorative materials.

    Science.gov (United States)

    Gürgan, S; Onen, A; Köprülü, H

    1997-03-01

    Daily application of mouthrinses has been recommended for the prevention and control of caries and periodontal disease. The aim of this study was to evaluate the effect of alcohol-containing and alcohol-free mouthrinses on the microhardness of three restorative materials. Materials tested included visible light cured (VLC) composite resin (Amelogen), VLC glass-ionomer cement (Fuji II LC) and a fissure sealant (Ultra Seal XT). Eighteen cylinders of each restorative were fabricated and initially stored in distilled water for 24 h. Six samples of the restoratives were stored for 12 hours to simulate a 2 min/day for 1 year exposure to mouthrinses in the following solutions: distilled water (control), alcohol-containing mouthrinse (Viadent) and alcohol-free mouthrinse (Rembrandt). At the end of the test period microhardness was measured with a Tukon microhardness tester. Kruskal-Wallis one-way analysis of variance was used to analyse the data. Both mouthrinses affected the hardness of the materials tested.

  15. FIBRIN GLUE DAN APLIKASINYA

    Directory of Open Access Journals (Sweden)

    Agi Harliani S

    2015-08-01

    Full Text Available Fibrin Tissue Adhesive (FTA, Fibrin Sealant (FS or Fibrin Glue (FG are names given to a group of product that lead to the formation of fibrin clot at the site of application. Fibrin Glue represents a new revolution for local haemostatic, which produced by based on the understanding about blood coagulation process. The mechanism of FG mimics the last stage of blood coagulation process. Haemophilia, is a congenital inherited bleeding disorder, characterized by repeated bleeding episodes. The basic pathology is deficiency of factor VIII (hemophilia A or factor IX (hemophilia B. At bleeding episodes, hemophilia patients need replacement therapy. Hemophilia patients need transfusion of cryoprecipitate, Fresh Frozen Plasma (FFP or factor concentrate as replacement therapy. Oral surgery, dental extraction, circumcision, and orthopedic operations are the most important indications for fibrin glue in hemophilia care. As haemostatic local, FG minimizes bleeding, reducing the need of transfusion or factor concentrate, reducing the complication of transfusion, hospitalization and cost.

  16. Beeswax-Colophony Blend: A Novel Green Organic Coating for Protection of Steel Drinking Water Storage Tanks

    Directory of Open Access Journals (Sweden)

    Sara Abdikheibari

    2015-09-01

    Full Text Available Beeswax-colophony blend is mainly used as a sealant mixture for preservation applications. The beeswax itself, however, has had a long way in history taking part in conservation processes including mummification. In this research, this blend was used as a protective coating for drinking water distribution tanks. Initially, a layer with 400 μm thickness was applied on a sand blasted mild steel plate. The long-term electrochemical behavior of the coating was investigated by open circuit potential (OCP and electrochemical microbiological characteristics of the coating, microbial and chemical examinations were performed on drinking water samples that had been in contact with the coating. Furthermore, its behavior in an up-flow anaerobic sludge blanket reactor (UASBR in a wastewater treatment plant was investigated using the scanning electron microscopy (SEM technique. Regarding the consistency of experimental results, it was concluded that this proposed recyclable blend could be considered as a novel green organic coating and also a good corrosion barrier even in aggressive environments.

  17. Three-Dimensional Printing of Bisphenol A-Free Polycarbonates.

    Science.gov (United States)

    Zhu, Wei; Pyo, Sang-Hyun; Wang, Pengrui; You, Shangting; Yu, Claire; Alido, Jeffrey; Liu, Justin; Leong, Yew; Chen, Shaochen

    2018-02-14

    Polycarbonates are widely used in food packages, drink bottles, and various healthcare products such as dental sealants and tooth coatings. However, bisphenol A (BPA) and phosgene used in the production of commercial polycarbonates pose major concerns to public health safety. Here, we report a green pathway to prepare BPA-free polycarbonates (BFPs) by thermal ring-opening polymerization and photopolymerization. Polycarbonates prepared from two cyclic carbonates in different mole ratios demonstrated tunable mechanical stiffness, excellent thermal stability, and high optical transparency. Three-dimensional (3D) printing of the new BFPs was demonstrated using a two-photon laser direct writing system and a rapid 3D optical projection printer to produce structures possessing complex high-resolution geometries. Seeded C3H10T1/2 cells also showed over 95% viability with potential applications in biological studies. By combining biocompatible BFPs with 3D printing, novel safe and high-performance biomedical devices and healthcare products could be developed with broad long-term benefits to society.

  18. The effect of aging on the fracture toughness of esthetic restorative materials.

    Science.gov (United States)

    Bagheri, Rafat; Azar, Mohammad R; Tyas, Martin J; Burrow, Michael F

    2010-06-01

    To compare the fracture toughness (KIc) of tooth-colored restorative materials based on a four-point bending; to assess the effect of distilled water and a resin surface sealant (G-Coat Plus) on the resistance of the materials to fracture. Specimens were prepared from six materials: Quix Fil; Dyract (Dentsply), Freedom (SDI), Fuji VII (GC), Fuji IX (GC); Fuji II LC (GC). Fuji II LC and Fuji IX were tested both with and without applying G-Coat Plus (GC). The specimens were divided into the three groups which were conditioned in distilled water at 37 degrees C for 48 hours, 4 and 8 weeks. The specimens were loaded in a four-point bending test using a universal testing machine. The maximum load to specimen failure was recorded and the fracture toughness calculated. There were significant differences among most of the materials (P G-Coat Plus affected Fuji II LC positively while it had no effect on the Fuji IX.

  19. Thermally conductive cementitious grouts for geothermal heat pumps. Progress report FY 1998

    Energy Technology Data Exchange (ETDEWEB)

    Allan, M.L.; Philippacopoulos, A.J.

    1998-11-01

    Research commenced in FY 97 to determine the suitability of superplasticized cement-sand grouts for backfilling vertical boreholes used with geothermal heat pump (GHP) systems. The overall objectives were to develop, evaluate and demonstrate cementitious grouts that could reduce the required bore length and improve the performance of GHPs. This report summarizes the accomplishments in FY 98. The developed thermally conductive grout consists of cement, water, a particular grade of silica sand, superplasticizer and a small amount of bentonite. While the primary function of the grout is to facilitate heat transfer between the U-loop and surrounding formation, it is also essential that the grout act as an effective borehole sealant. Two types of permeability (hydraulic conductivity) tests was conducted to evaluate the sealing performance of the cement-sand grout. Additional properties of the proposed grout that were investigated include bleeding, shrinkage, bond strength, freeze-thaw durability, compressive, flexural and tensile strengths, elastic modulus, Poisson`s ratio and ultrasonic pulse velocity.

  20. Field Trial of an Aerosol-Based Enclosure Sealing Technology

    Energy Technology Data Exchange (ETDEWEB)

    Harrington, Curtis [Univ. of California, Davis, CA (United States); Springer, David [Alliance for Residential Building Innovation (ARBI), Davis, CA (United States)

    2015-09-01

    This report presents the results from several demonstrations of a new method for sealing building envelope air leaks using an aerosol sealing process developed by the Western Cooling Efficiency Center at UC Davis. The process involves pressurizing a building while applying an aerosol sealant to the interior. As air escapes through leaks in the building envelope, the aerosol particles are transported to the leaks where they collect and form a seal that blocks the leak. Standard blower door technology is used to facilitate the building pressurization, which allows the installer to track the sealing progress during the installation and automatically verify the final building tightness. Each aerosol envelope sealing installation was performed after drywall was installed and taped, and the process did not appear to interrupt the construction schedule or interfere with other trades working in the homes. The labor needed to physically seal bulk air leaks in typical construction will not be replaced by this technology.