WorldWideScience

Sample records for sealant package insert

  1. Clinical information in drug package inserts in India

    Directory of Open Access Journals (Sweden)

    Shivkar Y

    2009-01-01

    Full Text Available Background: It is widely recognized that accurate and reliable product information is essential for the safe and effective use of medications. Pharmaceutical companies are the primary source of most drug information, including package inserts. Package inserts are printed leaflets accompanying marketed drug products and contain information approved by the regulatory agencies. Studies on package inserts in India, in 1996, had shown that crucial information was often missing and they lacked uniformity. Aim: To assess the presentation and completeness of clinically important information provided in the currently available package inserts in India. Materials and Methods: Package inserts accompanying allopathic drug products marketed by pharmaceutical companies in India were collected. These package inserts were analyzed for the content of clinically important information in various sections. Statistical Analysis: The results were expressed as absolute numbers and percentages. Results: Preliminary analyses revealed that most package inserts did contain information under headings, such as, therapeutic indications, contraindications, undesirable effects, etc., listed in the Drugs and Cosmetics Rules 1945. The findings indicated considerable improvement in package inserts since 1996. However, on critical evaluation it was revealed that clinically important information was not well presented and was often incomplete. Information with regard to pediatric and geriatric use was present in only 44% and 13% of the package inserts, respectively. Only five of the inserts had information on the most frequent adverse drug reactions associated with the drug. Also, information on interactions and overdosage was often missing. Conclusion: Although the package inserts appear to have improved over the past decade there is still a definite need to further refine the clinical information contained, to minimize the risks to patients. This could be brought about by self

  2. A proposal for a drug information database and text templates for generating package inserts

    Directory of Open Access Journals (Sweden)

    Okuya R

    2013-07-01

    Full Text Available Ryo Okuya,1 Masaomi Kimura,2 Michiko Ohkura,2 Fumito Tsuchiya3 1Graduate School of Engineering and Science, 2Faculty of Engineering, Shibaura Institute of Technology, Tokyo, 3School of Pharmacy, International University of Health and Welfare, Tokyo, Japan Abstract: To prevent prescription errors caused by information systems, a database to store complete and accurate drug information in a user-friendly format is needed. In previous studies, the primary method for obtaining data stored in a database is to extract drug information from package inserts by employing pattern matching or more sophisticated methods such as text mining. However, it is difficult to obtain a complete database because there is no strict rule concerning expressions used to describe drug information in package inserts. The authors' strategy was to first build a database and then automatically generate package inserts by embedding data in the database using templates. To create this database, the support of pharmaceutical companies to input accurate data is required. It is expected that this system will work, because these companies can earn merit for newly developed drugs to decrease the effort to create package inserts from scratch. This study designed the table schemata for the database and text templates to generate the package inserts. To handle the variety of drug-specific information in the package inserts, this information in drug composition descriptions was replaced with labels and the replacement descriptions utilizing cluster analysis were analyzed. To improve the method by which frequently repeated ingredient information and/or supplementary information are stored, the method was modified by introducing repeat tags in the templates to indicate repetition and improving the insertion of data into the database. The validity of this method was confirmed by inputting the drug information described in existing package inserts and checking that the method could

  3. Readability assessment of package inserts of biological medicinal products from the European medicines agency website.

    Science.gov (United States)

    Piñero-López, Ma Ángeles; Modamio, Pilar; Lastra, Cecilia F; Mariño, Eduardo L

    2014-07-01

    Package inserts that accompany medicines are a common source of information aimed at patients and should match patient abilities in terms of readability. Our objective was to determine the degree of readability of the package inserts for biological medicinal products commercially available in 2007 and compare them with the readability of the same package inserts in 2010. A total of 33 package inserts were selected and classified into five groups according to the type of medicine: monoclonal antibody-based products, cytokines, therapeutic enzymes, recombinant blood factors and other blood-related products, and recombinant hormones. The package inserts were downloaded from the European Medicines Agency website in 2007 and 2010. Readability was evaluated for the entire text of five of the six sections of the package inserts and for the 'Annex' when there was one. Three readability formulas were used: SMOG (Simple Measure of Gobbledygook) grade, Flesh-Kincaid grade level, and Szigriszt's perspicuity index. No significant differences were found between the readability results for the 2007 package inserts and those from 2010 according to any of the three readability indices studied (p>0.05). However, there were significant differences (preadability scores of the sections of the package inserts in both 2007 and 2010. The readability of the package inserts was above the recommended sixth grade reading level (ages 11-12) and may lead to difficulties of understanding for people with limited literacy. All the sections should be easy to read and, therefore, the readability of the medicine package inserts studied should be improved.

  4. Patients Comprehension of Pharmaceutical Package Inserts ...

    African Journals Online (AJOL)

    Tropical Journal of Pharmaceutical Research December 2015; 14 (12): ... Available online at http://www.tjpr.org ... patients/consumers about PPI. ... the perception of outpatients of Karachi about ... Do you store the medication at the temperature specified in the package insert ... drugs available in local market of Pakistan was.

  5. Dental sealants

    Science.gov (United States)

    ... this page: //medlineplus.gov/ency/patientinstructions/000779.htm Dental sealants To use the sharing features on this ... case a sealant needs to be replaced. How Dental Sealants are Applied Your dentist applies sealants on ...

  6. Glass ionomer ART sealants in Chinese school children-6-year results.

    Science.gov (United States)

    Holmgren, Christopher J; Lo, Edward C M; Hu, Deyu

    2013-09-01

    To evaluate longitudinally ART sealants placed in Chinese school children under field conditions. 191 ART sealants were placed in 140 children, aged 11-14 years, by five assistant dentists in four secondary schools in Deyang, Sichuan Province, China. Teeth selected for sealing were those with pits and fissures that were deep or showing early enamel caries. Teeth were excluded if there was obvious cavitation extending into dentine. Standard instruments and procedures for ART sealants were used. The material used was a high-viscosity glass-ionomer (Ketac-Molar, 3MESPE) that was inserted into the pits and fissures with the "press-finger" technique. The status of the sealants was evaluated annually over 6 years after placement by the same examiner who was not involved in the placement of the sealants using explorers, mouth-mirrors and an intra-oral fibre-optic light. No missing sealants were replaced during the study. 107 sealants (56% of the original) were examined after 6 years. The cumulative survival rates of the sealants (partially or fully retained) after 2, 4 and 6 years were 79%, 68% and 59%, respectively. Caries prevention lagged the fall in sealant survival but remained high throughout the study period, being over 90% in the first 4 years and 85% after 6 years. ART sealants placed under field conditions in Chinese schoolchildren have a high retention rate. Missing sealants should be replaced to maintain their preventive efficacy. The sealing of pits and fissures can be an effective caries preventive approach. Resin-based sealants have the disadvantage in that they require an optimal level of moisture control during placement. In children and in outreach situations glass ionomer ART sealants, which are more moisture tolerant, can offer a viable alternative. Copyright © 2013 Elsevier Ltd. All rights reserved.

  7. Analysis on descriptions of precautionary statements in package inserts of medicines

    Directory of Open Access Journals (Sweden)

    Tsuchiya F

    2012-02-01

    Full Text Available Keita Nabeta1, Masaomi Kimura2, Michiko Ohkura2, Fumito Tsuchiya31Graduate School of Engineering and Science, Shibaura Institute of Technology, Toyosu 3-7-5, Koto-ku, Tokyo, 135-8548 Japan; 2Faculty of Engineering, Shibaura Institute of Technology, Toyosu 3-7-5, Koto-ku, Tokyo, 135-8548 Japan; 3School of Pharmacy, International University of Health and Welfare, Minami-Aoyama 1-24-1, Minato-ku, Tokyo, 107-0062 JapanBackground: To prevent medical accidents, users must be informed of the cautions written in medical package inserts. To realize countermeasures by utilizing information systems, we must also implement a drug information database. However, this is not easy to develop, since the descriptions in package inserts are too complex and their information poorly structured. It is necessary to analyze package insert information and propose a data structure.Methods: We analyzed the descriptions of 'precautions for application' in package inserts via text mining methods. In order to summarize statements, we applied dependency analysis to statements and visualized their relations between predicate words and other words. Furthermore, we extracted words representing timing to execute the order.Results: We found that there are four types of statements: direct orders such as "使用する" (use, causative orders such as "使用させる" (make someone use, direct interdictions such as "使用しない" (do not use, and causative interdictions such as "使用させない" (do not make user use. As for words representing timing, we extracted six groups: "at the time of delivery," "at the time of preparation," "in use," "after use," and "at the time of storage." From these results, we obtained points of consideration concerning the subjects of orders in the statements and timing of their execution.Conclusion: From the obtained knowledge, we can define the information structure used to describe the precautionary statement. It should contain information such

  8. Dental Sealants Prevent Cavities

    Science.gov (United States)

    ... Digital Press Kit Read the MMWR Science Clips Dental Sealants Prevent Cavities Effective protection for children Language: ... more use of sealants and reimbursement of services. Dental care providers can Apply sealants to children at ...

  9. Qualidade das bulas de fitoterápicos no Brasil | Quality of the package inserts of phytomedicines in Brazil

    Directory of Open Access Journals (Sweden)

    Marcia Maria Barros dos Passos

    2016-05-01

    Full Text Available O objetivo deste trabalho foi avaliar se as bulas de medicamentos fitoterápicos industrializados estão de acordo com a legislação nacional vigente. Foram analisadas 41 bulas dos medicamentos fitoterápicos compostos por alcachofra, castanha da Índia, ginkgo e sene, adquiridas nos sites das empresas titulares dos registros. A análise foi feita quanto à presença de itens segundo a RDC nº 47 de 2009 e ao conteúdo de indicação de uso, posologia e reações adversas comparada às bulas padrão e à literatura científica. A análise quantitativa provou que as bulas têm cumprido o que é exigido pela legislação vigente. No entanto, quanto à análise qualitativa, todos os fitoterápicos analisados neste trabalho possuíam pelo menos uma bula com erro relacionado à posologia, indicações de uso e reações adversas. Houve uma melhora gradativa das bulas dos medicamentos fitoterápicos, porém mesmo com as bulas padrão ainda existem erros, que podem induzir o paciente ao uso incorreto do medicamento. -----------------------------------------------------------------------------------------------The objective of this study was to assess whether the package inserts of industrialized phytomedicines are in line with current Brazilian legislation or not. Forty-one package inserts of phytomedicines containing artichoke, horse chestnut, ginkgo and senna were accessed in the respective proprietary websites and then analyzed. The analysis aimed to verify the presence of items required by the normative RDC 47/2009 and the usage indication, dosage and side effects compared to standard package inserts and to the scientific literature. Quantitative analysis proved that the package inserts are in accordance with the current legislation. However, in qualitative analysis, all phytomedicines analyzed in this study had at least one error related to dosage, posology or adverse reactions. A gradual improvement of the package inserts of phytomedicines has

  10. The state-of-the-art of ART sealants.

    Science.gov (United States)

    Frencken, Jo E

    2014-03-01

    Sealing caries-prone pits and fissure systems is an effective caries-preventive measure. There are basically two types of sealant materials: glass-ionomer and resin-based materials. Low- and medium-viscosity glass-ionomers were initially used and showed a low level of retention. With the advent of the ART approach in the mid-nineties, high-viscosity glass-ionomers were introduced as sealant material and the retention rate of ART sealants increased substantially. As the effectiveness of a sealant is measured by its capacity to prevent (dentine) carious lesion development, sealant retention is considered a surrogate endpoint. The ART sealant protocol is described. Systematic reviews and meta-analysis covering low- medium- and high-viscosity glass-ionomer (ART) sealants have concluded that there is no evidence that either glass-ionomer or resin-based sealants prevent dentine carious lesions better. The annual dentine carious lesion development in teeth with high-viscosity glass-ionomer ART sealants over the first three years is 1%. These ART sealants have a high capacity of preventing carious lesion development. Because no electricity and running water is required, ART sealants can be placed both inside and outside the dental surgery. High-viscosity glass-ionomer ART sealants can be used alongside resin-based sealants.41:119-124

  11. Comparative study of resin sealant and resin modified glass ionomer as pit and fissure sealant

    Directory of Open Access Journals (Sweden)

    Shirin Malek

    2017-02-01

    Full Text Available The purpose of the present study was to compare the marginal integrity of resin modified glass ionomer cement with that of resin sealant, in vitro. Forty artificial pit and fissure cavities were prepared in occlusal surface of extracted premolar teeth by using ¼ round carbide bur. Cavities were condensed with artificial organic debris followed by cleaning with prophylaxis pumice brush and paste and then separated into two treatment groups. In Group A, 15 fissure cavities were sealed by resin sealant and in Group B, 15 fissure cavities were sealed by resin modified glass ionomer sealant. These specimens were subjected to thermo-cycling followed by dye penetration test. The remaining 5 cavities from each group were analyzed for debris score by the SEM. The results of the microleakage test showed that the efficacy of preventing microleakage of samples sealed by resin modified glass ionomer sealant was higher than the samples sealed by resin sealant. However, no significant differences were found. It can be concluded that use of resin modified glass ionomer sealant is a good alternative for sealing pits and fissures.

  12. Parametric Study of Sealant Nozzle

    Science.gov (United States)

    Yamamoto, Yoshimi

    It has become apparent in recent years the advancement of manufacturing processes in the aerospace industry. Sealant nozzles are a critical device in the use of fuel tank applications for optimal bonds and for ground service support and repair. Sealants has always been a challenging area for optimizing and understanding the flow patterns. A parametric study was conducted to better understand geometric effects of sealant flow and to determine whether the sealant rheology can be numerically modeled. The Star-CCM+ software was used to successfully develop the parametric model, material model, physics continua, and simulate the fluid flow for the sealant nozzle. The simulation results of Semco sealant nozzles showed the geometric effects of fluid flow patterns and the influences from conical area reduction, tip length, inlet diameter, and tip angle parameters. A smaller outlet diameter induced maximum outlet velocity at the exit, and contributed to a high pressure drop. The conical area reduction, tip angle and inlet diameter contributed most to viscosity variation phenomenon. Developing and simulating 2 different flow models (Segregated Flow and Viscous Flow) proved that both can be used to obtain comparable velocity and pressure drop results, however; differences are seen visually in the non-uniformity of the velocity and viscosity fields for the Viscous Flow Model (VFM). A comprehensive simulation setup for sealant nozzles was developed so other analysts can utilize the data.

  13. Retention of a resin-based sealant and a glass ionomer used as a fissure sealant: A comparative clinical study

    Directory of Open Access Journals (Sweden)

    Subramaniam P

    2008-09-01

    Full Text Available Sealing occlusal pits and fissures with resin-based sealants is a proven method of preventing occlusal caries. Retention of the sealant is very essential for its efficiency. This study evaluated the retention of glass ionomer used as a fissure sealant when compared to a self-cure resin-based sealant. One hundred and seven children between the ages of 6-9 years, with all four newly erupted permanent first molars were selected. Two permanent first molars on one side of the mouth were sealed with Delton, a resin-based sealant, and the contralateral two permanent first molars were sealed with Fuji VII glass ionomer cement. Evaluation of sealant retention was performed at regular intervals over 12 months, using Simonsen′s criteria. At the end of the study period, the retention of the resin sealant was seen to be superior to that of the glass ionomer sealant.

  14. Moisture-tolerant resin-based sealant: A boon

    Directory of Open Access Journals (Sweden)

    Prasanna Kumar Bhat

    2013-01-01

    Full Text Available Background and Objectives: Pit and fissure sealants are highly effective in preventing occlusal caries. The present study clinically evaluated and compared the retention and development of caries when sealed with moisture-tolerant resin-based sealant, conventional resin-based sealant with and without a bonding agent, and Glass Ionomer Cement Sealant in young permanent teeth. Materials and Methods: A total of 80 healthy cooperative children aged 6-9 years who were at high caries risk with all four newly erupted permanent first molars were included in the study. Teeth were divided into 4 groups using a full-factorial design, and each of the molars was sealed with the four different sealant material. Evaluation of sealant retention and development of caries was performed at 6 and 12 months using Modified Simonsen′s criteria. The data obtained were tabulated and subjected to statistical analysis using Kruskal-Wallis Test and Mann-Whitney Test. Result and Conclusion: The result from the present study indicated that moisture-tolerant resin-based sealant could be successfully used as a pit and fissure sealant because its hydrophilic chemistry makes it less technique sensitive and simplifies the sealant application procedure.

  15. Use of sealants: societal and professional factors.

    Science.gov (United States)

    Frazier, P J

    1984-02-01

    At present, sealant use continues at a low level in private practice by dentists and hygienists, and is moderate in community programs although there is high interest in their use in public health settings. Widespread delegation of sealant application to hygienists has not occurred even though the majority of state dental practice acts allow it, and even though practicing hygienists are highly interested in applying sealants. Use in federally sponsored programs is minimal or nonexistent. Information about sealants and adequate clinical experience in their application appear minimal in dental training institutions, and few opportunities have existed for continuing education. Generally, knowledge about sealants among dentists is low; many hold doubtful opinions. Insurance carriers, including commercial, provider, and governmental programs, appear reluctant to reimburse for sealants without purchaser demand and organized dentistry's blessings. Although society emphasizes patient rights to informed consent, few opportunities exist for the public, including group insurance purchasers and union negotiators, to learn about sealant use in conjunction with appropriate fluoride use. Public educational materials are sparse. Manufacturer marketing efforts at present, aimed at providers alone, are at best minimal, with a few exceptions; those targeting the public are nonexistent. Organized dentistry's Council statements may have contributed to a constriction, to date, in the flow of public information about sealants from industry. Lack of communication, or miscommunication, between practitioners and dental scientists has resulted in much misinformation and confusion about the value of sealants and their use. And, the contemporary status of dental manpower and the economy of dental practice in the private sector appear to have provided an infertile environment for acceptance of sealants as a primary preventive technology. In the public sector, interest in sealants is high but

  16. Durability of building joint sealants

    Science.gov (United States)

    Christopher C. White; Kar Tean Tan; Donald L. Hunston; R. Sam Williams

    2009-01-01

    Predicting the service life of building joint sealants exposed to service environments in less than real time has been a need of the sealant community for many decades. Despite extensive research efforts to design laboratory accelerated tests to duplicate the failure modes occurring in field exposures, little success has been achieved using conventional durability...

  17. Dental Sealants

    Science.gov (United States)

    ... that protect the chewing surfaces of children’s back teeth from tooth decay. Overall, the prevalence of sealants in children’s and adolescent’s teeth has increased since the early 1970s. In spite ...

  18. Do light cured ART conventional high-viscosity glass-ionomer sealants perform better than resin-composite sealants: a 4-year randomized clinical trial

    NARCIS (Netherlands)

    Zhang, W.; Chen, X.; Fan, M.W.; Mulder, J.; Huysmans, M.C.D.N.J.M.; Frencken, J.E.F.M.

    2014-01-01

    OBJECTIVE: The hypotheses tested were: the cumulative survival rates of dentin caries lesion-free pits and fissures of ART conventional high-viscosity glass-ionomer sealants with light-curing (high-intensity LED) and glass-carbomer sealants are higher than those of conventional ART sealants and

  19. Sealants for preventing dental decay in the permanent teeth

    DEFF Research Database (Denmark)

    Ahovuo-Saloranta, Anneli; Forss, Helena; Walsh, Tanya

    2013-01-01

    of bias and two studies at high risk of bias), 482 children evaluated; risk ratio (RR) 0.24, 95% CI 0.12 to 0.45, one study at unclear risk of bias, 203 children evaluated).- Glass ionomer sealant compared with no sealant: There is insufficient evidence to make any conclusions about whether glass ionomer......, outcomes, time of outcomes reported and background fluoride exposure if this was reported.Fifteen trials compared glass ionomer with resin sealants and there is insufficient evidence to make any conclusions about the superiority of either of the two materials. Although there were 15 trials the event rate...... was very low in many of these which restricted their contribution to the results.Three trials compared resin-modified glass ionomer with resin sealant and reported inconsistent results.Two small low quality trials compared polyacid-modified resin sealants with resin sealants and found no difference...

  20. Dental Sealants Prevent Cavities PSA (:60)

    Centers for Disease Control (CDC) Podcasts

    This 60 second public service announcement is based on the October 2016 CDC Vital Signs report. Dental sealants, applied soon after a child's permanent molars come in, can protect against cavities for up to nine years. Applying sealants in schools for low-income children could save millions in dental treatment costs.

  1. THE EFFECT OF BONDING AND SURFACE SEALANT APPLICATION ON POSTOPERATIVE SENSITIVITY FROM POSTERIOR COMPOSITES

    Directory of Open Access Journals (Sweden)

    Neslihan TEKÇE

    2015-10-01

    Full Text Available Purpose: The purpose of the study was to evaluate the postoperative sensitivity of posterior Class I composite restoration at short-term, restorated with two different all-in-one self-etch adhesives with or without surface sealant application. Materials and Methods: 44 restorations were inserted in 11 patients who required Class I restorations in their molars. Each patient received 4 restorations, thus four groups were formed; (1 G-Aenial Bond (GC, Japan; (2 Clearfil S3 Bond (Kuraray, Japan; (3 G-Aenial Bond+Fortify Plus (Bisco, USA, (4 Clearfil S3 Bond+Fortify Plus. Sensitivity was evaluated at 24h, 7, 15, and 30 days using cold air, ice, and pressure stimuli using a visual analog scale. Comparisons of continuous variables between the sensitivity evaluations were performed using the Friedman’s One-Way Analysis of Variance with repeated measures test (p0.05. The use of Clearfil S3 Bond resulted in almost the same level of postoperative sensitivity as did the use of G-Aenial Bond. The highest sensitivity scores were observed for the surface sealant applied teeth without any statistical significance (p>0.05. Conclusions: Self etch adhesives displayed postoperative sensitivity. The sensitivity scores slightly decreased at the end of 30 days (p>0.05. Surface sealant application did not result in a decrease in sensitivity scores for either dentin adhesives.

  2. Fibrin Sealants in Dura Sealing: A Systematic Literature Review.

    Directory of Open Access Journals (Sweden)

    Felice Esposito

    Full Text Available Fibrin sealants are widely used in neurosurgery to seal the suture line, provide watertight closure, and prevent cerebrospinal fluid leaks. The aim of this systematic review is to summarize the current efficacy and safety literature of fibrin sealants in dura sealing and the prevention/treatment of cerebrospinal fluid leaks.A comprehensive electronic literature search was run in the following databases: Cochrane Database of Systematic Reviews, Cochrane Central Resister of Controlled Trials, clinicaltrials.gov, MEDLINE/PubMed, and EMBASE. Titles and abstracts of potential articles of interest were reviewed independently by 3 of the authors.A total of 1006 database records and additional records were identified. After screening for duplicates and relevance, a total of 78 articles were assessed by the investigators for eligibility. Thirty-eight were excluded and the full-text of 40 articles were included in the qualitative synthesis. Seven of these included only safety data and were included in the safety assessment. The remaining 33 articles included findings from 32 studies that enrolled a total of 2935 patients who were exposed to fibrin sealant. Among these 33 studies there were only 3 randomized controlled trials, with the remaining being prospective cohort analysis, case controlled studies, prospective or retrospective case series. One randomized controlled trial, with 89 patients exposed to fibrin sealant, found a greater rate of intraoperative watertight dura closure in the fibrin sealant group than the control group (92.1% versus 38.0%, p0.05. Other clinical trials evaluated the effect of fibrin sealant in the postoperative prevention of cerebrospinal fluid leaks. These were generally lower level evidence studies (ie, not prospective, randomized, controlled trials that were not designed or powered to demonstrate a significant advantage to fibrin sealant use. Two small case series studies evaluated the effect of fibrin sealants in

  3. Development of a Novel Alginate-Based Pleural Sealant

    Science.gov (United States)

    2016-07-01

    thoracotomy is performed on a anesthetized ventilated live rat (a), an incision is made to induce pleural air leak (b), and sealant material [ liquid ...AWARD NUMBER: W81XWH-15-1-0107 TITLE: Development of a Novel Alginate-Based Pleural Sealant PRINCIPAL INVESTIGATOR: Daniel J. Weiss MD PhD...SUBTITLE Development of a Novel Alginate-Based Pleural Sealant 5a. CONTRACT NUMBER 5b. GRANT NUMBER W81XWH-15-1-0107 5c. PROGRAM ELEMENT NUMBER 6. AUTHOR

  4. Role of Fibrin Sealants in Liver Surgery

    NARCIS (Netherlands)

    de Boer, Marieke T.; Boonstra, Elizabeth A.; Lisman, Ton; Porte, Robert J.

    2012-01-01

    Background: Fibrin sealants are widely used in liver surgery. The aim of this article is to review the literature on evidence of hemostatic and biliostatic capacities of different fibrin sealants in liver surgery. Methods: In PubMed, a literature search was done with the search terms 'fibrin

  5. Two-year survival of glass ionomer sealants placed as part of ...

    African Journals Online (AJOL)

    , ... Results: The two-year cumulative survival of the sealants was 10.9%, and the survival of the sealants was not significantly affected by the GIC material brand and the toothisolation method used. However, slightly more sealants survived ...

  6. Dental Sealants Prevent Cavities PSA (:60)

    Centers for Disease Control (CDC) Podcasts

    2016-10-18

    This 60 second public service announcement is based on the October 2016 CDC Vital Signs report. Dental sealants, applied soon after a child's permanent molars come in, can protect against cavities for up to nine years. Applying sealants in schools for low-income children could save millions in dental treatment costs.  Created: 10/18/2016 by National Center for Chronic Disease Prevention and Health Promotion (NCCDPHP).   Date Released: 10/18/2016.

  7. Testing Cessation Messages for Cigarette Package Inserts: Findings from a Best/Worst Discrete Choice Experiment

    Directory of Open Access Journals (Sweden)

    James F. Thrasher

    2018-02-01

    Full Text Available This study assessed smokers’ responses to different smoking cessation topics and imagery for cigarette package inserts. Adult smokers from Canada (n = 1000 participated in three discrete choice experiments (DCEs: DCE 1 assessed five cessation benefit topics and five imagery types; DCE 2 assessed five messages with tips to improve cessation success and five imagery types; DCE 3 assessed four reproductive health benefits of cessation topics and four imagery types. In each DCE, participants evaluated four or five sets of four inserts, selecting the most and least motivating (DCEs 1 & 3 or helpful (DCE 2 for quitting. Linear mixed models regressed choices on insert and smoker characteristics. For DCE 1, the most motivating messages involved novel disease topics and imagery of younger women. For DCE 2, topics of social support, stress reduction and nicotine replacement therapy were selected as most helpful, with no differences by imagery type. For DCE 3, imagery influenced choices more than topic, with imagery of a family or a mom and baby selected as most motivating. Statistically significant interactions for all three experiments indicated that the influence of imagery type on choices depended on the message topic. Messages to promote smoking cessation through cigarette pack inserts should consider specific combinations of message topic and imagery.

  8. Systematic review on the use of matrix-bound sealants in pancreatic resection.

    Science.gov (United States)

    Smits, F Jasmijn; van Santvoort, Hjalmar C; Besselink, Marc G H; Borel Rinkes, Inne H M; Molenaar, I Quintus

    2015-11-01

    Pancreatic fistula is a potentially life-threatening complication after a pancreatic resection. The aim of this systematic review was to evaluate the role of matrix-bound sealants after a pancreatic resection in terms of preventing or ameliorating the course of a post-operative pancreatic fistula. A systematic search was performed in the literature from May 2005 to April 2015. Included were clinical studies using matrix-bound sealants after a pancreatic resection, reporting a post-operative pancreatic fistula (POPF) according to the International Study Group on Pancreatic Fistula classification, in which grade B and C fistulae were considered clinically relevant. Two were studies on patients undergoing pancreatoduodenectomy (sealants n = 67, controls n = 27) and four studies on a distal pancreatectomy (sealants n = 258, controls n = 178). After a pancreatoduodenectomy, 13% of patients treated with sealants versus 11% of patients without sealants developed a POPF (P = 0.76), of which 4% versus 4% were clinically relevant (P = 0.87). After a distal pancreatectomy, 42% of patients treated with sealants versus 52% of patients without sealants developed a POPF (P = 0.03). Of these, 9% versus 12% were clinically relevant (P = 0.19). The present data do not support the routine use of matrix-bound sealants after a pancreatic resection, as there was no effect on clinically relevant POPF. Larger, well-designed studies are needed to determine the efficacy of sealants in preventing POPF after a pancreatoduodenectomy. © 2015 International Hepato-Pancreato-Biliary Association.

  9. Use of fibrin sealants in cardiovascular surgery: a systematic review.

    Science.gov (United States)

    Rousou, John A

    2013-05-01

    Fibrin sealants are used for hemostasis and tissue adherence. This systematic review summarizes published clinical data for fibrin sealant use in cardiovascular surgery. A literature search for the following terms was conducted using PubMed and EMBASE: (TISSEEL or Tissucol or Beriplast P or Evicel or Quixil or Crosseal or Reliseal or Fibringluraas or Bolheal or Tachosil or Vivostat or Vitagel or Artiss or "fibrin glue" or "fibrin sealant" or "fibrin tissue adhesive") and (cardiac or cardiovascular or vascular or heart or coronary or surgery). Case reports and series were excluded; although reports of controlled trials were preferred, uncontrolled trial data were also considered. Clinical trials and chart review analyses of fibrin sealants were identified and summarized. Although clinical trial data were available for other agents, the majority of published studies examined TISSEEL. Overall, TISSEEL and other fibrin sealants showed improvements over standard of care or control groups for a variety of predefined endpoints. Safety findings are also summarized. Data from these studies showed that fibrin sealants were well tolerated and provided effective hemostasis in a range of cardiac and aortic surgeries. © 2013 Wiley Periodicals, Inc.

  10. Public judgments of information in a diazepam patient package insert.

    Science.gov (United States)

    Fisher, S; Mansbridge, B; Lankford, D A

    1982-06-01

    As part of a larger study of the effects of giving patients written take-home information with prescription medications, a "patient package insert" (PPI) for diazepam was prepared based on content determined by "experts." This report compares the experts' judgments of what information should be included with judgments obtained from the public. Information judged to be most important for inclusion in a PPI was identified by having subjects sort cards containing facts about diazepam. Subjects who had previously used diazepam were no different in their judgments than inexperienced subjects. In general, there was a high degree of concordance between public and expert judgments and also a remarkably strong consensus across very different demographic samples. In those few instances of disagreement, the public attached even greater importance to warnings and "bad news" about diazepam than to information providing reassurances, benign general education, and "good news." To what extent patients would effectively use this information--whether conveyed by PPIs or alternative educational routes--must await empirical evaluation.

  11. Conformity of package inserts information to regulatory requirements among selected branded and generic medicinal products circulating on the East African market.

    Science.gov (United States)

    Sillo, Hiiti B; Masota, Nelson E; Kisoma, Sunday; Rago, Lembit; Mgoyela, Veronica; Kaale, Eliangiringa A

    2018-01-01

    Availability of correct and adequate information about medicines is an important aspect in ensuring rational use of medicines and hence facilitating safety and expected efficacy of medicines during therapy. Package inserts have proven to be a good source of information to the prescribers and patients whereby they have been useful in highlighting important information pertaining proper use and handling of the medicines. The present study was aimed at establishing the extent to which package inserts of medicines circulating on the markets of the East African Community (EAC) Partner States conform to medicines information requirements as established in the harmonized guidelines as well as national guidelines. A total of 99 package inserts from six (6) types of medicines namely Albendazole, Artemether/Lumefantrine (ALu), Ciprofloxacin, Paracetamol, Amoxicillin and Metronidazole were purposefully collected from three EAC Partner States: Kenya, Tanzania and Uganda. The medicines were selected based on their indications as first line treatments, high rates of utilization within the medicines supply system and their positions in treatment of diseases of public importance across EAC Partner States. The inserts were evaluated on the availability of information regarding fifteen (15) parameters as extracted from the EAC harmonized guidelines for registration of medicines. Moreover, comparisons were made between the percentage conformity of the branded versus generic products, markets from which the samples were collected, origin of the manufacturer and type of medicine. Majority (93.9-100%) of the medicines' package inserts highly conformed to the inclusion of the information regarding the description and composition of the medications, indications, dosage and methods of administration, warnings and precautions, contraindications and storage conditions. However, the information on handling and disposal, container package description, excipients used, clinical pharmacology of

  12. Toxicity of coal-tar and asphalt sealants to eastern newts, Notophthalmus viridescens

    Energy Technology Data Exchange (ETDEWEB)

    Bommarito, T.; Sparling, D.W.; Halbrook, R.S. [South Illinois University, Carbondale, IL (United States). Cooperative Wildlife Research Laboratory

    2010-09-15

    Between 1970 and 2000 the concentration of total polycyclic aromatic hydrocarbons (TPAH) in several lakes across the country increased whereas those of other persistent organic pollutants (POPs) tended to remain stable or declined. Urbanized watersheds experienced greater rises in TPAH concentration compared to non-urban lakes. Sources for urban PAHs include industrial wastes, vehicular exhausts and oil leaks and sealants from pavement surfaces. Both coal-tar and asphalt sealants are used to protect surfaces but runoff from surfaces coated with coal-tar can have mean concentrations of 3500 mg TPAHs kg{sup -1}, much higher than runoff from asphalt-sealed or cement surfaces. Unaltered parent compounds of PAHs can have many lethal and sublethal toxic effects, but oxidation and UV radiation can alter the toxicity of these compounds, sometimes creating degradates that are many times more toxic than parent compounds. The purposes of this study were to determine if coal-tar sealants can be toxic to adult eastern newts (Notophthalmus viridescens) and to compare the toxicity of coal-tar sealant to that of asphalt sealant. Newts were exposed to sediments containing dried sealants ranging from 0 mg kg{sup -1} to 1500 mg kg{sup -1} under simultaneous exposure to UV radiation and visible light to determine concentration/response relationships. No significant mortality occurred with any treatment. Significant effects due to sealants included decreased righting ability and diminished liver enzyme activities. Coal-tar sealant was more effective in inducing these changes than was asphalt sealant.

  13. Effect of chain extender on properties of silicone rubber sealant

    Science.gov (United States)

    Liu, Jiesheng; Wu, Shaopeng; Mi, Yixuan; Zhu, Guojun; Zheng, Shaoping

    2010-03-01

    The room-temperature vulcanizing silicone rubber sealant was prepared with chain extender. The effect of chain extender on the properties of silicone rubber sealant was discussed. The composite samples with chain extender were investigated from the aspects of tack-free time, cross-linkage density, hardness (penetration number) and adhesive strength with the concrete slab. It was found that the adding of the chain extender effectively makes the molecular chain length increase and causes the mechanical properties improvement. In addition, the increase in the amount of the chain extender reduces the cross-linkage density and hardness of silicone rubber sealant, which is accompanied with a decrease in the tack-free time. Adhesive strength is one of the most important requirements for sealant. The effect of chain extender on the adhesive strength was also investigated in this study. It was found that the increase in the amount of the chain extender makes the adhesive strength between the sealant and the concrete slab decrease.

  14. A 1-year clinical evaluation of fissure sealants on permanent first molars

    Directory of Open Access Journals (Sweden)

    Nupur Ninawe

    2012-01-01

    Full Text Available Objective : To evaluate and compare the retention, marginal discoloration, surface texture and anatomical form of pit and fissure sealants. Materials and Methods : Thirty children between the ages of 6 and 10 years, who were attending the school health program regularly, had participated in the study. A split-mouth design was used in which the two fissure sealants (Helioseal-F and Glass ionomer Fuji VII were randomly placed in 60 matched contralateral pairs of permanent molar teeth. Sealants were rated by a single trained and calibrated examiner using mouth mirrors and probes following the US Public Health Service criteria. The sealants were evaluated at 3 months, 6 months and 1 year intervals. Results : The data obtained for retention, marginal discoloration, surface texture and anatomical form of pit and fissure sealants were tabulated and compared statistically using the Chi-square test of significance. Conclusion : The Helioseal-F sealant was better than the Glass ionomer Fuji VII sealant with respect to retention, anatomical form and surface texture. Both the materials showed similar results with respect to marginal discoloration.

  15. Tensile strength of biological fibrin sealants: a comparative study.

    Science.gov (United States)

    Lacaze, Laurence; Le Dem, Nicolas; Bubenheim, Michael; Tsilividis, Basile; Mezghani, Julien; Schwartz, Lilian; Francois, Arnaud; Ertaud, Jean Yves; Bagot d'Arc, Maurice; Scotté, Michel

    2012-08-01

    Fibrin sealants are commonly used in liver surgery, although their effectiveness in routine clinical practice remains controversial. Individual sealant characteristics are based on hemostatic effects and adhesion properties that can be experimentally measured using the 'rat skin test' or the 'pig skin test'. This study used a more relevant and realistic experimental canine model to compare the differences in the adhesive properties of four fibrin sealants in hepatectomy: Tisseel/Tissucol, Tachosil, Quixil, and Beriplast. A partial hepatectomy was performed in beagle dogs under general anesthesia to obtain liver cross-sections. Fibrin sealants were allocated to dog livers using a Youden square design. The tensile strength measurement was performed using a traction system to measure the rupture stress point of a small wooden cylinder bonded to the liver cross-section. Significantly greater adhesion properties were observed with Tisseel/Tissucol compared with Quixil or Beriplast (P = 0.002 and 0.001, respectively). Similarly, Tachosil demonstrated significantly greater adhesive properties compared with Beriplast (P = 0.009) or Quixil (P = 0.014). No significant differences were observed between Tisseel/Tissucol and Tachosil or between Beriplast and Quixil. The results of this comparative study demonstrate that different fibrin sealants exhibit different adhesive properties. Tisseel/Tissucol and Tachosil provided greatest adhesion to liver cross-section in our canine model of hepatectomy. These results may enable the optimal choice of fibrin sealants for this procedure in clinical practice. Copyright © 2012 Elsevier Inc. All rights reserved.

  16. Coal-tar based pavement sealant toxicity to freshwater macroinvertebrates

    International Nuclear Information System (INIS)

    Bryer, Pamela J.; Scoggins, Mateo; McClintock, Nancy L.

    2010-01-01

    Non-point-source pollution is a major source of ecological impairment in urban stream systems. Recent work suggests that coal-tar pavement sealants, used extensively to protect parking areas, may be contributing a large portion of the polycyclic aromatic hydrocarbon (PAH) loading seen in urban stream sediments. The hypothesis that dried coal-tar pavement sealant flake could alter the macroinvertebrate communities native to streams in Austin, TX was tested using a controlled outdoor laboratory type approach. The treatment groups were: control, low, medium, and high with total PAH concentrations (TPAH = sum of 16 EPA priority pollutant PAHs) of 0.1, 7.5, 18.4, and 300 mg/kg respectively. The low, medium, and high treatments were created via the addition of dried coal-tar pavement sealant to a sterile soil. At the start of the 24-day exposure, sediment from a minimally impacted local reference site containing a community of live sediment-dwelling benthic macroinvertebrates was added to each replicate. An exposure-dependent response was found for several stream health measures and for several individual taxa. There were community differences in abundance (P = 0.0004) and richness (P < 0.0001) between treatments in addition to specific taxa responses, displaying a clear negative relationship with the amount of coal-tar sealant flake. These results support the hypothesis that coal-tar pavement sealants contain bioavailable PAHs that may harm aquatic environments. - Coal-tar pavement sealants degrade stream invertebrate communities.

  17. Comparison of microleakage between flowable nanocomposite, flowable Composite and Conventional sealant in fissure sealant therapy of the permanent teeth: an in- vitro study

    Directory of Open Access Journals (Sweden)

    Sara Maleki Kambakhsh

    2016-11-01

    Full Text Available Background and Aim: Novel dental materials including nanocomposites have been introduced in recent years. It is claimed that they have superior properties such as high esthetic., low wear, increased filler content resulting in better mechanical properties, and releasing ions i.e. fluoride and amorphous calcium phosphate that are important for enamel remineralization. Considering these features, if they have retention and microleakage rates comparable with conventional sealants, these materials can be appropriate alternatives to conventional resin sealants in future. The current study aimed at comparing . microleakage of a flowable nanocomposite, a flowable composite , and a conventional sealant in fissure sealant therapy of the permanent teeth. Materials and Methods: First of all ,42 extracted sound human maxillary first premolars were collected and were randomly divided into 3 equal groups. Then the teeth were embedded in self-cure acrylic resin. Occlusal fissures of the samples were cleaned using explorer, enameloplasty with ¼ round diamond bur and water/air spray was done. The prepared surfaces were etched using 36% phosphoric acid gel for 15s, rinsed and dried. Bonding agent was placed in the pits and fissures, cured for 10s after thinning with air. In the first, second , and the third group conventional sealant, flowable composite , and flowable nanocomposite were placed, respectively; and light cured for 40s. The samples were thermocycled (1000 cycles between 5-55ºC and then immersed in 2% basic Fuchsine solution for 24hs. They were then cut bucculingually and microleakage evaluation was done using stereomicroscope. The obtained data was analyzed using Kruskal wallis tests. Results: There was no significant difference in microleakage rate of the study groups. (P>0.05. Conclusion: Considering the condition of the study, it can be concluded that flowable composite and flowable nanocomposite can be used as suitable alternatives to

  18. Synthetic phenolic antioxidants, including butylated hydroxytoluene (BHT), in resin-based dental sealants

    Energy Technology Data Exchange (ETDEWEB)

    Wang, Wei; Kannan, Pranav; Xue, Jingchuan [Wadsworth Center, New York State Department of Health, and Department of Environmental Health Sciences, School of Public Health, State University of New York at Albany, Empire State Plaza, P.O. Box 509, Albany, NY 12201-0509 (United States); Kannan, Kurunthachalam, E-mail: Kurunthachalam.kannan@health.ny.gov [Wadsworth Center, New York State Department of Health, and Department of Environmental Health Sciences, School of Public Health, State University of New York at Albany, Empire State Plaza, P.O. Box 509, Albany, NY 12201-0509 (United States); Biochemistry Department, Faculty of Science, Experimental Biochemistry Unit, King Fahd Medical Research Center, King Abdulaziz University, Jeddah (Saudi Arabia)

    2016-11-15

    Resin-based dental sealants (also referred to as pit-and-fissure sealants) have been studied for their contribution to bisphenol A (BPA) exposure in children. Nevertheless, little attention has been paid to the occurrence of other potentially toxic chemicals in dental sealants. In this study, the occurrence of six synthetic phenolic antioxidants (SPAs), including 2,6-di-tert-butyl-4-hydroxytoluene (BHT), 2,6-di-tert-butyl-4-(hydroxyethyl)phenol (BHT-OH), 3,5-di-tert-butyl-4-hydroxy-benzaldehyde (BHT-CHO), 2,6-di-tert-butylcyclohexa-2,5-diene-1,4-dione (BHT-Q), 3,5-di-tert-butyl-4-hydroxybenzoic acid (BHT-COOH) and 2-tert-butyl-4-methoxyphenol (BHA), was examined in 63 dental sealant products purchased from the U.S. market. BHT was found in all dental sealants at median and maximum concentrations of 56.8 and 1020 µg/g, respectively. The metabolites of BHT and BHA were detected in 39–67% of samples, at concentration ranges of sealants to inhibit oxidative reactions, remove free radicals, and inhibit potential polymerization, which would eventually prolong the shelf-life of the products. The estimated daily intake (EDI) of BHT, following sealant placement, based on a worst-case scenario (application on eight teeth at 8 mg each tooth), was 930 and 6510 ng/kg bw/d for adults and children, respectively. The EDI of BHT from dental sealants was several orders of magnitude lower than the current acceptable daily intake (ADI) proposed by the European Food Safety Authority (EFSA). - Highlights: • Synthetic phenolic antioxidants (SPAs) were detected in dental sealants. • 2,6-di-tert-butyl-4-hydroxytoluene (BHT) concentration of up to 1020 µg/g was found. • Estimated daily intake of BHT after sealant placement was up to 9.52 µg/kg bw/d. • Daily intake of BHT through dental sealant application was below the acceptable daily intake.

  19. Synthetic phenolic antioxidants, including butylated hydroxytoluene (BHT), in resin-based dental sealants

    International Nuclear Information System (INIS)

    Wang, Wei; Kannan, Pranav; Xue, Jingchuan; Kannan, Kurunthachalam

    2016-01-01

    Resin-based dental sealants (also referred to as pit-and-fissure sealants) have been studied for their contribution to bisphenol A (BPA) exposure in children. Nevertheless, little attention has been paid to the occurrence of other potentially toxic chemicals in dental sealants. In this study, the occurrence of six synthetic phenolic antioxidants (SPAs), including 2,6-di-tert-butyl-4-hydroxytoluene (BHT), 2,6-di-tert-butyl-4-(hydroxyethyl)phenol (BHT-OH), 3,5-di-tert-butyl-4-hydroxy-benzaldehyde (BHT-CHO), 2,6-di-tert-butylcyclohexa-2,5-diene-1,4-dione (BHT-Q), 3,5-di-tert-butyl-4-hydroxybenzoic acid (BHT-COOH) and 2-tert-butyl-4-methoxyphenol (BHA), was examined in 63 dental sealant products purchased from the U.S. market. BHT was found in all dental sealants at median and maximum concentrations of 56.8 and 1020 µg/g, respectively. The metabolites of BHT and BHA were detected in 39–67% of samples, at concentration ranges of sealants to inhibit oxidative reactions, remove free radicals, and inhibit potential polymerization, which would eventually prolong the shelf-life of the products. The estimated daily intake (EDI) of BHT, following sealant placement, based on a worst-case scenario (application on eight teeth at 8 mg each tooth), was 930 and 6510 ng/kg bw/d for adults and children, respectively. The EDI of BHT from dental sealants was several orders of magnitude lower than the current acceptable daily intake (ADI) proposed by the European Food Safety Authority (EFSA). - Highlights: • Synthetic phenolic antioxidants (SPAs) were detected in dental sealants. • 2,6-di-tert-butyl-4-hydroxytoluene (BHT) concentration of up to 1020 µg/g was found. • Estimated daily intake of BHT after sealant placement was up to 9.52 µg/kg bw/d. • Daily intake of BHT through dental sealant application was below the acceptable daily intake.

  20. Malaria rapid diagnostic kits: quality of packaging, design and labelling of boxes and components and readability and accuracy of information inserts

    Directory of Open Access Journals (Sweden)

    Bruggeman Cathrien

    2011-02-01

    Full Text Available Abstract Background The present study assessed malaria RDT kits for adequate and correct packaging, design and labelling of boxes and components. Information inserts were studied for readability and accuracy of information. Methods Criteria for packaging, design, labelling and information were compiled from Directive 98/79 of the European Community (EC, relevant World Health Organization (WHO documents and studies on end-users' performance of RDTs. Typography and readability level (Flesch-Kincaid grade level were assessed. Results Forty-two RDT kits from 22 manufacturers were assessed, 35 of which had evidence of good manufacturing practice according to available information (i.e. CE-label affixed or inclusion in the WHO list of ISO13485:2003 certified manufacturers. Shortcomings in devices were (i insufficient place for writing sample identification (n = 40 and (ii ambiguous labelling of the reading window (n = 6. Buffer vial labels were lacking essential information (n = 24 or were of poor quality (n = 16. Information inserts had elevated readability levels (median Flesch Kincaid grade 8.9, range 7.1 - 12.9 and user-unfriendly typography (median font size 8, range 5 - 10. Inadequacies included (i no referral to biosafety (n = 18, (ii critical differences between depicted and real devices (n = 8, (iii figures with unrealistic colours (n = 4, (iv incomplete information about RDT line interpretations (n = 31 and no data on test characteristics (n = 8. Other problems included (i kit names that referred to Plasmodium vivax although targeting a pan-species Plasmodium antigen (n = 4, (ii not stating the identity of the pan-species antigen (n = 2 and (iii slight but numerous differences in names displayed on boxes, device packages and information inserts. Three CE labelled RDT kits produced outside the EC had no authorized representative affixed and the shape and relative dimensions of the CE symbol affixed did not comply with the Directive 98/79/EC

  1. Malaria rapid diagnostic kits: quality of packaging, design and labelling of boxes and components and readability and accuracy of information inserts.

    Science.gov (United States)

    Gillet, Philippe; Maltha, Jessica; Hermans, Veerle; Ravinetto, Raffaella; Bruggeman, Cathrien; Jacobs, Jan

    2011-02-13

    The present study assessed malaria RDT kits for adequate and correct packaging, design and labelling of boxes and components. Information inserts were studied for readability and accuracy of information. Criteria for packaging, design, labelling and information were compiled from Directive 98/79 of the European Community (EC), relevant World Health Organization (WHO) documents and studies on end-users' performance of RDTs. Typography and readability level (Flesch-Kincaid grade level) were assessed. Forty-two RDT kits from 22 manufacturers were assessed, 35 of which had evidence of good manufacturing practice according to available information (i.e. CE-label affixed or inclusion in the WHO list of ISO13485:2003 certified manufacturers). Shortcomings in devices were (i) insufficient place for writing sample identification (n=40) and (ii) ambiguous labelling of the reading window (n=6). Buffer vial labels were lacking essential information (n=24) or were of poor quality (n=16). Information inserts had elevated readability levels (median Flesch Kincaid grade 8.9, range 7.1-12.9) and user-unfriendly typography (median font size 8, range 5-10). Inadequacies included (i) no referral to biosafety (n=18), (ii) critical differences between depicted and real devices (n=8), (iii) figures with unrealistic colours (n=4), (iv) incomplete information about RDT line interpretations (n=31) and no data on test characteristics (n=8). Other problems included (i) kit names that referred to Plasmodium vivax although targeting a pan-species Plasmodium antigen (n=4), (ii) not stating the identity of the pan-species antigen (n=2) and (iii) slight but numerous differences in names displayed on boxes, device packages and information inserts. Three CE labelled RDT kits produced outside the EC had no authorized representative affixed and the shape and relative dimensions of the CE symbol affixed did not comply with the Directive 98/79/EC. Overall, RDTs with evidence of GMP scored better

  2. Reimbursement rates and policies for primary molar pit-and-fissure sealants across state Medicaid programs.

    Science.gov (United States)

    Chi, Donald L; Singh, Jennifer

    2013-11-01

    Little is known about Medicaid policies regarding reimbursement for placement of sealants on primary molars. The authors identified Medicaid programs that reimbursed dentists for placing primary molar sealants and hypothesized that these programs had higher reimbursement rates than did state programs that did not reimburse for primary molar sealants. The authors obtained Medicaid reimbursement data from online fee schedules and determined whether each state Medicaid program reimbursed for primary molar sealants (no or yes). The outcome measure was the reimbursement rate for permanent tooth sealants (calculated in 2012 U.S. dollars). The authors compared mean reimbursement rates by using the t test (α = .05). Seventeen Medicaid programs reimbursed dentists for placing primary molar sealants (34 percent), and the mean reimbursement rate was $27.57 (range, $16.00 [Maine] to $49.68 [Alaska]). All 50 programs reimbursed dentists for placement of sealants on permanent teeth. The mean reimbursement for permanent tooth sealants was significantly higher in programs that reimbursed for primary molar sealants than in programs that did not ($28.51 and $23.67, respectively; P = .03). Most state Medicaid programs do not reimburse dentists for placing sealants on primary molars, but programs that do so have significantly higher reimbursement rates. Medicaid reimbursement rates are related to dentists' participation in Medicaid and children's dental care use. Reimbursement for placement of sealants on primary molars is a proxy for Medicaid program generosity.

  3. Pit and fissure sealants for preventing dental decay in the permanent teeth of children and adolescents

    DEFF Research Database (Denmark)

    Ahovuo-Saloranta, Anneli; Hiiri, Anne; Nordblad, Anne

    2008-01-01

    BACKGROUND: Although pit and fissure sealants are effective in preventing caries, their efficacy may be related to the caries prevalence in the population. OBJECTIVES: The primary objective of this review was to evaluate the caries prevention of pit and fissure sealants in children and adolescents...... for comparison of sealant versus sealant. Five split-mouth studies and one parallel group study with 5 to 10 year old children found a significant difference in favour of second or third generation resin-based sealants on first permanent molars, compared to a control without sealant, with a pooled RR of 0.13 (95...... sealant group; 27% of sealed surfaces were decayed compared to 77% of surfaces without sealant.The results of the studies comparing different sealant materials were conflicting. AUTHORS' CONCLUSIONS: Sealing is a recommended procedure to prevent caries of the occlusal surfaces of permanent molars...

  4. Wellbore Completion Systems Containment Breach Solution Experiments at a Large Scale Underground Research Laboratory : Sealant placement & scale-up from Lab to Field

    Science.gov (United States)

    Goodman, H.

    2017-12-01

    This investigation seeks to develop sealant technology that can restore containment to completed wells that suffer CO2 gas leakages currently untreatable using conventional technologies. Experimentation is performed at the Mont Terri Underground Research Laboratory (MT-URL) located in NW Switzerland. The laboratory affords investigators an intermediate-scale test site that bridges the gap between the laboratory bench and full field-scale conditions. Project focus is the development of CO2 leakage remediation capability using sealant technology. The experimental concept includes design and installation of a field scale completion package designed to mimic well systems heating-cooling conditions that may result in the development of micro-annuli detachments between the casing-cement-formation boundaries (Figure 1). Of particular interest is to test novel sealants that can be injected in to relatively narrow micro-annuli flow-paths of less than 120 microns aperture. Per a special report on CO2 storage submitted to the IPCC[1], active injection wells, along with inactive wells that have been abandoned, are identified as one of the most probable sources of leakage pathways for CO2 escape to the surface. Origins of pressure leakage common to injection well and completions architecture often occur due to tensile cracking from temperature cycles, micro-annulus by casing contraction (differential casing to cement sheath movement) and cement sheath channel development. This discussion summarizes the experiment capability and sealant testing results. The experiment concludes with overcoring of the entire mock-completion test site to assess sealant performance in 2018. [1] IPCC Special Report on Carbon Dioxide Capture and Storage (September 2005), section 5.7.2 Processes and pathways for release of CO2 from geological storage sites, page 244

  5. Coal-tar based pavement sealant toxicity to freshwater macroinvertebrates

    Energy Technology Data Exchange (ETDEWEB)

    Bryer, P.J.; Scoggins, M.; McClintock, N.L. [Lamar University, Beaumont, TX (United States). Dept. of Biology

    2010-05-15

    Non-point-source pollution is a major source of ecological impairment in urban stream systems. Recent work suggests that coal-tar pavement sealants, used extensively to protect parking areas, may be contributing a large portion of the polycyclic aromatic hydrocarbon (PAH) loading seen in urban stream sediments. The hypothesis that dried coal-tar pavement sealant flake could alter the macroinvertebrate communities native to streams in Austin, TX was tested using a controlled outdoor laboratory type approach. The treatment groups were: control, low, medium, and high with total PAH concentrations (TPAH = sum of 16 EPA priority pollutant PAHs) of 0.1, 7.5, 18.4, & 300 mg/kg respectively. The low, medium, and high treatments were created via the addition of dried coal-tar pavement sealant to a sterile soil. At the start of the 24-day exposure, sediment from a minimally impacted local reference site containing a community of live sediment-dwelling benthic macroinvertebrates was added to each replicate. An exposure-dependent response was found for several stream health measures and for several individual taxa. There were community differences in abundance (P = 0.0004) and richness (P < 0.0001) between treatments in addition to specific taxa responses, displaying a clear negative relationship with the amount of coal-tar sealant flake. These results support the hypothesis that coal-tar pavement sealants contain bioavailable PAHs that may harm aquatic environments.

  6. Sealants fight back aginst bacteria.

    Science.gov (United States)

    Moran, Mike

    2008-09-01

    Mike Moran, business development manager, Industrial Construction, at Bostik, explains how a range of new sealants increase protection in hospital bathrooms, shower rooms and kitchen facilities against healthcare-acquired infections.

  7. Evaluation of a sealant intervention program among Taiwanese aboriginal schoolchildren

    Directory of Open Access Journals (Sweden)

    Hui-Ju Hsieh

    2014-06-01

    Conclusion: The application of pit-and-fissure sealants was 94.54% effective in preventing caries on newly erupted permanent molars among Taiwanese aboriginal schoolchildren. Complete sealant failure demonstrated a high risk for caries, and such teeth should immediately be resealed.

  8. Effect of an Antibacterial Monomer on the Antibacterial Activity of a Pit-and-Fissure Sealant.

    Directory of Open Access Journals (Sweden)

    Fan Yu

    Full Text Available Resin-based pit-and-fissure sealants are often used to form a barrier on the occlusal surface of molars to treat caries lesions; however, bacteria can remain in the pit and fissures without detection, increasing the risk of secondary caries. Sealants with antimicrobial properties or microbial repellent actions might be advantageous. The aim of this study was to assess the inhibitory effect of a 2-methacryloxylethyl dodecyl methyl ammonium bromide (MAE-DB-incorporated sealant against Streptococcus mutans. MAE-DB (4% wt was incorporated into a commercially available sealant, Eco-S resin-based pit-and-fissure sealant (Vericom Co., Ltd., Korea; a sealant without MAE-DB served as a negative control, and Clinpro™ Sealant (3M™ ESPE™, a fluoride-releasing resin, was used as a commercial control. The effects of the cured sealants and their eluents on the growth of S. mutans were determined according to colony-forming unit counts and metabolic tests. The effects of the cured sealants on the adherence and membrane integrity of S. mutans were investigated using confocal laser-scanning microscopy (CLSM in conjunction with fluorescent indicators. Compared with the negative control and commercial control, the cured MAE-DB-incorporated pit-and-fissure sealant exhibited a significant inhibitory effect on the growth of S. mutans (P < 0.05, whereas the eluents did not show any detectable antibacterial activity. The commercial control also showed no detectable bactericidal activity. Moreover, the aged experimental material retained its property of contact inhibition of biofilm formation. The fluorescence analysis of CLSM images demonstrated that the cured MAE-DB-incorporated sealant could hamper the adherence of S. mutans and exert a detrimental effect on bacterial membrane integrity. The incorporation of MAE-DB can render a pit-and-fissure sealant with contact antibacterial activity after polymerization via influencing the growth, adherence, and membrane

  9. CDC Vital Signs–Dental Sealants Prevent Cavities

    Centers for Disease Control (CDC) Podcasts

    This podcast is based on the October 2016 CDC Vital Signs report. Dental sealants, applied soon after a child's permanent molars come in, can protect against cavities for up to nine years. Applying sealants in schools for low-income children could save millions in dental treatment costs.

  10. Process for nondestructively testing with radioactive gas using a chill set sealant

    International Nuclear Information System (INIS)

    Gibbons, C.B.

    1975-01-01

    An article surface is nondestructively tested for substantially invisible surface voids by absorbing a radioactive gas thereon. The adsorbed radioactive gas is disproportionately retained on those surfaces presented by the substantially invisible surface voids as compared to the remaining surfaces of the article contacted by the radioactive gas. The radiation released by the radioactive gas remaining adsorbed is used to identify the substantially invisible voids. To immobilize the radioactive gas adjacent or within the surface voids, a sealant composition is provided which is capable of being chill set. The temperatures of the article surface to be tested and the sealant composition are then related so that the article surface is at a temperature below the chill set temperature of the sealant composition and the sealant composition is at a temperature above its chill set temperature. The article portion to be tested is then coated with sealant composition to form a chill set coating thereon of substantially uniform thickness. (U.S.)

  11. Effect of a surface sealant on the color stability of composite resins after immersion in staining solution.

    Science.gov (United States)

    Pedroso, Lauana Borges; Barreto, Luma Franciélle Cabreira; Miotti, Leonardo Lamberti; Nicoloso, Gabriel Ferreira; Durand, Leticia Brandão

    2016-01-01

    This study evaluated the influence of surface sealants on the color stability of 2 different composite resins after immersion in coffee. Four groups were created (n = 10): microhybrid composite, microhybrid with surface sealant, nanofilled composite, and nanofilled composite with surface sealant. Half of the specimens of each group were immersed in distilled water and half were immersed in coffee for 48 hours. Color was measured before and after immersion. Groups with surface sealants presented less color variation when compared with the groups without surface sealants. The nanofilled resin specimens presented the greatest color variation within the groups without sealant. The surface sealant positively influenced the color stability of composite resin specimens immersed in coffee. When surface sealant was not applied, the microhybrid specimens had better color stability than the nanofilled.

  12. The effect of bonding agents on the microleakage of sealant following contamination with saliva

    Directory of Open Access Journals (Sweden)

    Askarizadeh Nahid

    2008-06-01

    Full Text Available Aims : An issue of concern in dentistry is the inadequacy of adhesion and proper sealing following restoration of a tooth, which can lead to marginal leakage. The aim of this study was to evaluate the effect of a bonding agent on the microleakage of a sealant material following contamination with saliva. Materials and Methods : In this experimental research, 48 sound premolars were divided into two groups. The first group received sealant without bonding and the other group was given sealant with bonding. After prophylaxis, the occlusal surfaces were etched with 37% phosphoric acid gel and the teeth were then placed in fresh human saliva for l0 s. Following this, in the first group fissure sealant (Kerr was applied directly and cured; for the second group sealant was placed and cured after bonding (Single Bond; 3M. All samples were thermocycled (500 cycles; between 5°C and 55°C; dwell time of 30 s. Silver nitrate was used as the leakage tracer. The teeth were sectioned. Microleakage evaluation was made by stereomicroscope at 40x magnification and the results were evaluated with the Mann-Whitney U test. Results : In the group that received sealant without bonding extensive microleakage was seen; placement of sealant with bonding significantly reduced microleakage. Conclusion : In the presence of contamination with saliva, use of bonding under the fissure sealant can reduce microleakage

  13. Dental sealant knowledge, opinion, values and practice of Spanish dentists

    Directory of Open Access Journals (Sweden)

    San Martin Laura

    2013-02-01

    Full Text Available Abstract Background Multiple guidelines and systematic reviews recommend sealant use to reduce caries risk. Yet, multiple reports also indicate that sealants are significantly underutilized. This study examined the knowledge, opinions, values, and practice (KOVP of dentists concerning sealant use in the southwest region of Andalusia, Spain. This is a prelude to the generation of a regional plan for improving children’s oral health in Andalusia. Methods The survey’s target population was dentists working in western Andalusia, equally distributed in the provinces of Seville, Cadiz, and Huelva (N=2,047. A convenience sample of meeting participants and meeting participant email lists (N=400 were solicited from the annual course on Community and Pediatric Dentistry. This course is required for all public health sector dentists, and is open to all private sector dentists. Information on the dentist’s KOVP of sealants was collected using four-part questionnaire with 31, 5-point Likert-scaled questions. Results The survey population demographics included 190 men (48% and 206 women (52% with an average clinical experience of 10.6 (± 8.4 years and 9.3 (± 7.5 years, respectively. A significant sex difference was observed in the distribution of place of work (urban/suburb (p=0.001, but no sex differences between working sector (public/private. The mean ± SD values for each of the four KOVP sections for pit and fissure sealants were: knowledge = 3.57 ± 0.47; opinion = 2.48 ± 0.47; value = 2.74 ± 0.52; and practice = 3.48 ± 0.50. No sex differences were found in KOVP (all p >0.4. Independent of sex: knowledge statistically differed by years of experience and place of work; opinion statistically differed by years of experience and sector; and practice statistically differed by years of experience and sector. Less experienced dentists tended to have slightly higher scores (~0.25 on a Likert 1–5 scale. Statistically significant correlations were

  14. Effect of Adhesive Application on Sealant Success: A Clinical Study of Fifth and Seventh Generation Adhesive Systems

    Directory of Open Access Journals (Sweden)

    Vaibhav Tandon

    2016-03-01

    Full Text Available Objectives: The aim of the study was to compare the effect of fifth and seventh generation bonding agent on sealant success.Materials and Methods: Sixty-four school children aged six to nine years received sealants in four permanent molars in a split mouth design, such that each patient received sealant in the first permanent molar with fifth generation bonding agent in one arch and seventh generation bonding agent in the other arch; contra-lateral molars were sealed with sealant alone. The evaluation was carried out at baseline, three months, six months and 12 months, according to the criteria by Feigal et al, in 2000. Chi- square test was used to analyze data at P<0.05 level of significance.Results: Statistically significant differences were found for sealant retention between fifth generation and sealant group, and fifth generation and seventh generation groups; whereas, no significant difference was found for sealant retention between seventh generation and sealant group at three, six and 12 months.Conclusion: As separate etch and rinse steps are not required for seventh generation bonding agents, and almost similar results were obtained for both sealant and seventh generation groups, it can be concluded that application of sealant along with a seventh generation bonding agent may enhance sealant success and can be used for caries prevention in preventive programs.Key words:  Pit and Fissure Sealants; Dental Caries; Adhesives

  15. Marginal leakage of two newer glass-ionomer-based sealant materials assessed using micro-CT.

    NARCIS (Netherlands)

    Chen, X.; Cuijpers, V.M.J.I.; Fan, M.; Frencken, J.E.F.M.

    2010-01-01

    OBJECTIVES: To test newer glass-ionomer-based materials as sealant materials. One glass-ionomer sealant was light-cured to obtain an early setting reaction. The null-hypothesis tested was: there is no difference in marginal leakage of sealants produced with high-viscosity glass-ionomer, with and

  16. Vital Signs: Dental Sealant Use and Untreated Tooth Decay Among U.S. School-Aged Children.

    Science.gov (United States)

    Griffin, Susan O; Wei, Liang; Gooch, Barbara F; Weno, Katherine; Espinoza, Lorena

    2016-10-21

    Tooth decay is one of the greatest unmet treatment needs among children. Pain and suffering associated with untreated dental disease can lead to problems with eating, speaking, and learning. School-based dental sealant programs (SBSP) deliver a highly effective intervention to prevent tooth decay in children who might not receive regular dental care. SBSPs benefits exceed their costs when they target children at high risk for tooth decay. CDC used data from the National Health and Nutrition Examination Survey (NHANES) 2011-2014 to estimate current prevalences of sealant use and untreated tooth decay among low-income (≤185% of federal poverty level) and higher-income children aged 6-11 years and compared these estimates with 1999-2004 NHANES data. The mean number of decayed and filled first molars (DFFM) was estimated for children with and without sealants. Averted tooth decay resulting from increasing sealant use prevalence was also estimated. All reported differences are significant at pdental sealant use has increased; however, most children have not received sealants. Increasing sealant use prevalence could substantially reduce untreated decay, associated problems, and dental treatment costs.

  17. Sealants in dentistry: outcomes of the ORCA saturday afternoon symposium 2007

    NARCIS (Netherlands)

    Splieth, C.H.; Ekstrand, K.R.; Alkilzy, M.; Clarkson, J.; Meyer-Lueckel, H.; Martignon, S.; Paris, S.; Pitts, N.B.; Rickets, D.N.; van Loveren, C.

    2010-01-01

    Sealants are a successful tool in caries prevention, but their role in preventive strategies after the caries decline has to be discussed. A survey of paediatric departments across Europe revealed that indications for pit and fissure sealants vary considerably, both nationally and internationally.

  18. Sealants in dentistry: outcomes of the ORCA Saturday Afternoon Symposium 2007

    DEFF Research Database (Denmark)

    Splieth, C H; Ekstrand, K R; Alkilzy, M

    2009-01-01

    Sealants are a successful tool in caries prevention, but their role in preventive strategies after the caries decline has to be discussed. A survey of paediatric departments across Europe revealed that indications for pit and fissure sealants vary considerably, both nationally and internationally...

  19. Evaluation of microtensile bond strength of different fissure sealants to bovine enamel.

    Science.gov (United States)

    Sen Tunc, E; Bayrak, S; Tuloglu, N; Ertas, E

    2012-03-01

    The aim of this study was to evaluate the microtensile bond strength (μTBS) of a new fissure sealant and compare it with conventional sealants which are applied to enamel alone, and also with self-etch and etch-and-rinse adhesives. Enamel specimens were prepared and randomly distributed into three groups according to fissure sealant (Aegis, Helioseal F, Helioseal Clear). Each group was then subdivided according to adhesive system (Clearfil S3, Single Bond, no adhesive). A universal testing machine was used to measure μTBS, and data were analysed using one-way ANOVA and Tukey's tests. μTBS values for all Aegis subgroups were significantly lower than for comparable Helioseal F and Helioseal Clear subgroups (p 0.05). In the Helioseal Clear group, μTBS values for Single Bond were significantly higher than for Clearfil S3 (p adhesive subgroups in the Aegis or Helioseal F groups (p > 0.05). Sealant μTBS values may be affected by material content. The addition of an adhesive may improve μTBS values of sealant to enamel. © 2012 Australian Dental Association.

  20. Effectiveness of two new types of sealants: retention after 2 years

    NARCIS (Netherlands)

    Chen, X.; Du, M.; Fan, M.; Mulder, J.; Huysmans, M.C.; Frencken, J.E.

    2012-01-01

    The hypotheses tested were: survival rate of fully and partially retained glass-carbomer sealants is higher than those of high-viscosity glass-ionomer, with and without energy supplied, and that of resin composite; survival rate of fully and partially retained sealants of high-viscosity

  1. PERBEDAAN TOPICAL FLUORIDE APPLICATION DAN FISSURE SEALANT DALAM MENCEGAH KARIES PADAGIGI MOLAR SATU

    Directory of Open Access Journals (Sweden)

    Pawarti Pawarti

    2017-07-01

    Full Text Available Abstract: Topical Fluoride Application And Fissure Sealant To Prevent Dental Caries Permanent First Molars. Anatomy pits and fissures of teeth are caries initiation vulnerable areas of the permanent molars that grow at the age of 6 years where children can not perform oral hygiene. Caries prevention can be done by closing the pits and fissures or application of fluoride (topical fluoride application on the surface of the teeth. The purpose of this study was to analyze the difference fissure sealants and topical application of fluoride to prevent dental caries of first permanent molars. This study was a quasi-experimental study with time series, a sample was taken by purposive 117-second grade students of SDN District of North Pontianak. Data were analyzed using t-test. The result showed that fissure sealant more effective in caries prevention of first permanent molar than topical fluoride application where there were none caries teeth after and month fissure sealant, 25% sealant partially off and 11% fully off. Teeth that have done fluoride after 6 months of 3.9% of dental caries, the eighth month of 5.4% of dental caries. There was a significant difference between the effectiveness of fissure sealants with topical application of fluoride to prevent dental caries in first permanent molars p-value < 0.05, after 6-month p-value: 0.004 and after 8-month p-value: 0.001. Abstrak: Topical Fluoride Application Dan Fissure Sealant Untuk Mencegah Karies Pada Gigi Molar Satu Permanen. Anatomi pit dan fisura gigi merupakan daerah rentan inisiasi karies gigi molar satu permanen yang tumbuh pada usia 6 tahun anak belum bisa melakukan kebersihan mulutnya. Pencegahan karies dapat dilakukan dengan cara menutup pit dan fissure atau pengolesan fluor (topical fluoride application pada permukaan gigi. Tujuan penelitian ini untuk menganalisis perbedaan efektivitas fissure sealant dan topical fluoride application untuk mencegah karies gigi molar satu permanen anak

  2. Pit and fissure sealants for preventing dental decay in permanent teeth

    DEFF Research Database (Denmark)

    Ahovuo-Saloranta, Anneli; Forss, Helena; Walsh, Tanya

    2017-01-01

    to 3 August 2016), and Embase Ovid (1980 to 3 August 2016). We searched ClinicalTrials.gov and the World Health Organization International Clinical Trials Registry Platform for ongoing trials to 3 August 2016. No restrictions were placed on language or date of publication. Selection criteria......Background: Dental sealants were introduced in the 1960s to help prevent dental caries, mainly in the pits and fissures of occlusal tooth surfaces. Sealants act to prevent bacteria growth that can lead to dental decay. Evidence suggests that fissure sealants are effective in preventing caries....... Further research with long follow-up is needed....

  3. The economics of pit and fissure sealants in preventive dentistry: a review.

    Science.gov (United States)

    Kitchens, Dinah H

    2005-08-15

    Oral diseases are progressive, cumulative, and become more intricate to treat with advancement. While dental caries is an infectious transmissible disease with children being at the highest risk, primary prevention can reduce this risk. Primary prevention in dentistry is usually considered to be community fluoridated water supplies, professional fluoride treatments, and pit and fissure sealants. While community fluoridated water supplies have been proven to be cost-effective, the cost-effectiveness of pit and fissure sealants has primarily been studied in school-based programs of children from low socio-economic backgrounds. Dental sealant programs are just one way to help increase primary prevention in the oral health disparities of children. The purpose of this paper is to review the literature regarding the cost-effectiveness of pit and fissure sealants as a preventive strategy in preventive dentistry.

  4. Self-Healable and Reprocessable Polysulfide Sealants Prepared from Liquid Polysulfide Oligomer and Epoxy Resin.

    Science.gov (United States)

    Gao, Wentong; Bie, Mengyao; Liu, Fu; Chang, Pengshan; Quan, Yiwu

    2017-05-10

    Polysulfide sealants have been commercially applied in many industrial fields. In this article, we study the self-healing property of the epoxy resin-cured polysulfide sealants for the first time. The obtained sealants showed a flexible range of ultimate elongation of 157-478% and a tensile strength of 1.02-0.75 MPa corresponding to different polysulfide oligomers. By taking advantage of the dynamic reversible exchange of disulfide bonds, polysulfide sealants exhibited good self-healing ability under a moderate thermal stimulus. A higher molecular weight and a lower degree of cross-linking of polysulfide oligomer were helpful in improving the ultimate elongation and healing efficiency of the polysulfide sealants. After subjecting to a temperature of 75 °C for 60 min, both the tensile strength and ultimate elongation of a fully cut sample, LP55-F, were restored to 91% of the original values, without affecting the sealing property. Furthermore, the sample exhibited excellent reshaping and reprocessing abilities. These outcomes offer a paradigm toward sustainable industrial applications of the polysulfide-based sealants.

  5. Coal-tar based pavement sealant toxicity to freshwater macroinvertebrates.

    Science.gov (United States)

    Bryer, Pamela J; Scoggins, Mateo; McClintock, Nancy L

    2010-05-01

    Non-point-source pollution is a major source of ecological impairment in urban stream systems. Recent work suggests that coal-tar pavement sealants, used extensively to protect parking areas, may be contributing a large portion of the polycyclic aromatic hydrocarbon (PAH) loading seen in urban stream sediments. The hypothesis that dried coal-tar pavement sealant flake could alter the macroinvertebrate communities native to streams in Austin, TX was tested using a controlled outdoor laboratory type approach. The treatment groups were: control, low, medium, and high with total PAH concentrations (TPAH = sum of 16 EPA priority pollutant PAHs) of 0.1, 7.5, 18.4, & 300 mg/kg respectively. The low, medium, and high treatments were created via the addition of dried coal-tar pavement sealant to a sterile soil. At the start of the 24-day exposure, sediment from a minimally impacted local reference site containing a community of live sediment-dwelling benthic macroinvertebrates was added to each replicate. An exposure-dependent response was found for several stream health measures and for several individual taxa. There were community differences in abundance (P = 0.0004) and richness (P pavement sealants contain bioavailable PAHs that may harm aquatic environments. Copyright 2009 Elsevier Ltd. All rights reserved.

  6. Does Fibrin Sealant Reduce Seroma after Immediate Breast Reconstruction Utilizing a Latissimus Dorsi Myocutaneous Flap?

    Directory of Open Access Journals (Sweden)

    Han Gyu Cha

    2012-09-01

    Full Text Available Background The most common complication of latissimus dorsi myocutaneous flap in breastreconstruction is seroma formation in the back. Many clinical studies have shown that fibrinsealant reduces seroma formation. We investigated any statistically significant differences inpostoperative drainage and seroma formation when utilizing the fibrin sealant on the site ofthe latissimus dorsi myocutaneous flap harvested for immediate breast reconstruction afterskin-sparing partial mastectomy.Methods A total of 46 patients underwent immediate breast reconstruction utilizing alatissimus dorsi myocutaneous island flap. Of those, 23 patients underwent the procedurewithout fibrin sealant and the other 23 were administered the fibrin sealant. All flaps wereelevated with manual dissection by the same surgeon and were analyzed to evaluate thepotential benefits of the fibrin sealant. The correlation analysis and Mann-Whitney U testwere used for analyzing the drainage volume according to age, weight of the breast specimen,and body mass index.Results Although not statistically significant, the cumulative drainage fluid volume was higherin the control group until postoperative day 2 (530.1 mL compared to 502.3 mL, but thefibrin sealant group showed more drainage beginning on postoperative day 3. The donor sitecomparisons showed the fibrin sealant group had more drainage beginning on postoperativeday 3 and the drain was removed 1 day earlier in the control group.Conclusions The use of fibrin sealant resulted in no reduction of seroma formation. Becausethe benefits of the fibrin sealant are not clear, the use of fibrin sealant must be fully discussedwith patients before its use as a part of informed consent.

  7. A review of bioceramics and fibrin sealant.

    Science.gov (United States)

    Le Guéhennec, L; Layrolle, P; Daculsi, G

    2004-09-13

    This review focuses on bone substitute composites made by mixing ceramic biomaterials with fibrin sealants. Different biomaterials such as coral, bone-derived materials, bioactive glass ceramics, and synthetic calcium phosphate have been mixed with fibrin sealant, resulting in a combination of the biological properties of the two components. This type of association has not produced identical results in all studies. In the past for some, the addition of fibrin sealant to the biomaterial failed to produce any significant, positive effect on osteointegration, whereas others found a positive impact on bone colonization. Despite the negative biological effects reported previously, bioceramic-fibrin composites have been widely used in various types of bone surgery because they are easy to manipulate. In particular, the intra-operative preparation of these composites makes it possible to add bone growth factors or autologous osteoprogenitor cells prior to bone reconstruction. The bone growth factors and autologous osteoprogenitor cells associated with the bioceramic-fibrin composites should provide surgeons with tissue engineered grafts with enhanced osteointegrative properties. This review discusses both the advantages and disadvantages, as well as the future perspectives, of using bioceramic-fibrin composites in various clinical indications.

  8. A Review of Bioceramics and Fibrin Sealant

    Directory of Open Access Journals (Sweden)

    Le Guéhennec L.

    2004-09-01

    Full Text Available This review focuses on bone substitute composites made by mixing ceramic biomaterials with fibrin sealants. Different biomaterials such as coral, bone-derived materials, bioactive glass ceramics, and synthetic calcium phosphate have been mixed with fibrin sealant, resulting in a combination of the biological properties of the two components. This type of association has not produced identical results in all studies. In the past for some, the addition of fibrin sealant to the biomaterial failed to produce any significant, positive effect on osteointegration, whereas others found a positive impact on bone colonization. Despite the negative biological effects reported previously, bioceramic-fibrin composites have been widely used in various types of bone surgery because they are easy to manipulate. In particular, the intra-operative preparation of these composites makes it possible to add bone growth factors or autologous osteoprogenitor cells prior to bone reconstruction. The bone growth factors and autologous osteoprogenitor cells associated with the bioceramic-fibrin composites should provide surgeons with tissue engineered grafts with enhanced osteointegrative properties. This review discusses both the advantages and disadvantages, as well as the future perspectives, of using bioceramic-fibrin composites in various clinical indications.

  9. Glass Composition for the use as a Sealant

    DEFF Research Database (Denmark)

    2014-01-01

    The invention concerns a glass composition for the use as a sealant, particularly in a solid oxide fuel cell (SOFC) or in a solid oxide electrolyser cell (SOEC). The glass composition comprises 35-70 mol% CaO, 5-45 mol% ZnO, 5-50 mol% B2O3, 1-45 mol% SiO2, and 1 mol% or less of each element...... of the group, comprising Ba, Na and Sr, based on the total glass composition. Furthermore, the invention relates to an SOFC and an SOEC employing a sealant of said glass composition....

  10. Stability of Beriplast P fibrin sealant: storage and reconstitution.

    Science.gov (United States)

    Eberhard, Ulrich; Broder, Martin; Witzke, Günther

    2006-04-26

    This study was performed to investigate the stability of Beriplast P fibrin sealant (FS) across a range of storage conditions, both pre- and post-reconstitution. Storage stability of the FS was evaluated during long-term refrigeration (24 months) with or without interim storage at elevated temperatures (40 degrees C for 1 week and 25 degrees C for 1 and 3 months). Stability of individual FS components was assessed by measuring: fibrinogen content, Factor XIII activity (FXIII), thrombin activity and aprotinin potency. The package integrity of each component was also checked (sterility testing, moisture content and pH). Storage stability was also evaluated by testing the reconstituted product for adhesion (tearing force testing after mixing the solutions) and sterility. Reconstitution stability was evaluated following 3-months' storage, for up to 50 h post-reconstitution using the same tests as for the storage stability investigations. Pre-defined specifications were met for fibrinogen content, Factor XIII activity, and thrombin activity, demonstrating storage stability. Package integrity and the functionality and sterility of the reconstituted product were confirmed throughout. Reconstitution stability was demonstrated for up to 50 h following reconstitution, in terms of both tearing force and sterility tests. In conclusion, the storage stability of Beriplast P was demonstrated over a range of 24-month storage schedules including interim exposure to elevated temperature, and the reconstituted product was stable for up to 50 h.

  11. Treatment of venous ulcers with fibrin sealant derived from snake venom

    Directory of Open Access Journals (Sweden)

    MAN Gatti

    2011-01-01

    Full Text Available Venous ulcers of the lower limbs complicated by infection or chronicity represent a serious public health problem. The elevated number of those afflicted burdens the health services, interferes in quality of life and causes absenteeism. Although there are 2,500 items on the market, ranging from the simplest dressing up to the most complex types of dressing, treatment remains a challenge. Among the substances used, fibrin sealant is the one that promotes diminution of bacterial colonization and of edema, controls hemorrhaging, alters the pain threshold by protecting the nerve endings, hydrates the wound bed and forms granulation tissue that favors healing. Its disadvantages include higher cost and utilization of human fibrinogen that can transmit infectious diseases. The Center for the Study of Venoms and Venomous Animals (CEVAP at São Paulo State University (UNESP developed a new sealant made up of fibrinogen extracted from large animals and from an enzyme obtained from snake venom. The present study, developed in the Health Education Clinic (CEPS of Sacred Heart University (USC aimed to evaluate the effect of the new sealant on the healing process of venous ulcers in 24 adult patients, seven of whom were male and 17 female. Two study groups were formed as follows: Group 1 (G1 - control group of 11 patients treated with essential fatty acid (EFA and Unna's boot, and Group 2 (G2 - 13 patients treated with essential fatty acid (EFA, fibrin sealant and Unna's boot. The follow-up lasted eight weeks and the sealant was applied at only the first and fourth weeks. The results showed that Group 2 presented worse lesion conditions as to healing, but, when comparing the two groups, it was noteworthy that the the sealant was effective in healing venous ulcers. There is evidence that the new sealant is recommended for leg ulcers with the following advantages: ease of application, preparation of the wound bed, diminution of pain and a higher number of

  12. Evaluation of pavement joint sealants :a new testing technique

    OpenAIRE

    Abo-Qudais, Saad A.

    1992-01-01

    A new method to evaluate the performance of sealants, used in rigid pavement joints, was developed. A special fixture was designed to transfer cyclic in-line deflection, applied by a testing machine, to cyclic normal and shear deflections on a sealant sandwiched between two-2 x 2 x 2 in. portland cement mortar cubes. The normal and shear deflections were applied simultaneously at a specific ratio controlled by the developed fixture. The new testing method simulates field ...

  13. A comparison between three different pit and fissure sealants with regard to marginal integrity.

    Science.gov (United States)

    Fernandes, Kristlee Sabrin; Chalakkal, Paul; de Ataide, Ida de Noronha; Pavaskar, Rajdeep; Fernandes, Precylia Philo; Soni, Harleen

    2012-04-01

    THE AIM OF THIS STUDY IS TO COMPARE THE OCCURRENCE OF ENAMEL FRACTURES, SEALANT FRACTURES AND MARGINAL FISSURES AFTER PLACEMENT OF THREE SEALANTS: Helioseal F, Conseal F and Clinpro. Thirty individuals between 13 and 15 years of age, diagnosed with pit and fissure caries by visual and DIAGNOdent examination, were chosen for sealant placement on their mandibular molars. The sealants were placed at random, after which, impressions were made with polyvinyl siloxane and casts were fabricated. Dies were prepared, each of which were sputter coated with gold in order to be examined under a scanning electron microscope. The following morphologies were analyzed from dies from each of the sealant groups: Continuous margins, sealant fractures, marginal fissures and enamel fractures. After six months, they were recalled for impression making. Dies were prepared and microscopically analyzed as mentioned. Based on the time of evaluation, there were two groups: Initial group (soon after placement) and final group (after six months). Statistical analysis was done using the paired 't' test and One-way analysis of variance (ANOVA). Clinpro had the greatest fracture resistance, followed by Conseal F and Helioseal F. The occurrence of marginal fissure was found to be least with Clinpro.

  14. Impact of adhesive and photoactivation method on sealant integrity and polymer network formation

    Directory of Open Access Journals (Sweden)

    Boniek Castillo Dutra Borges

    2012-06-01

    Full Text Available We evaluated the influence of photoactivation method and hydrophobic resin (HR application on the marginal and internal adaptation, hardness (KHN, and crosslink density (CLD of a resin-based fissure sealant. Model fissures were created in bovine enamel fragments (n = 10 and sealed using one of the following protocols: no adhesive system + photoactivation of the sealant using continuous light (CL, no adhesive system + photoactivation of the sealant using the soft-start method (SS, HR + CL, or HR + SS. Marginal and internal gaps and KHN were assessed after storage in water for 24 h. The CLD was indirectly assessed by repeating the KHN measurement after 24 h of immersion in 100% ethanol. There was no difference among the samples with regard to marginal or internal adaptation. The KHN and CLD were similar for samples cured using either photoactivation method. Use of a hydrophobic resin prior to placement of fissure sealants and curing the sealant using the soft-start method may not provide any positive influence on integrity or crosslink density.

  15. PAH volatilization following application of coal-tar-based pavement sealant

    Science.gov (United States)

    Van Metre, Peter C.; Majewski, Michael S.; Mahler, Barbara J.; Foreman, William T.; Braun, Christopher L.; Wilson, Jennifer T.; Burbank, Teresa L.

    2012-01-01

    Coal-tar-based pavement sealants, a major source of PAHs to urban water bodies, have recently been identified as a source of volatile PAHs to the atmosphere. We tracked the volatilization of PAHs for 1 year after application of a coal-tar-based pavement sealant by measuring gas-phase PAH concentrations above the pavement surface and solid-phase PAH concentrations in sealant scraped from the surface. Gas-phase concentrations at two heights (0.03 and 1.28 m) and wind speed were used to estimate volatilization flux. The sum of the concentrations of eight frequently detected PAHs (ΣPAH8) in the 0.03-m sample 1.6 h after application (297,000 ng m-3) was about 5000 times greater than that previously reported for the same height above unsealed parking lots (66 ng m-3). Flux at 1.6 h after application was estimated at 45,000 μg m-2 h-1 and decreased rapidly during the 45 days after application to 160 μg m-2 h-1. Loss of PAHs from the adhered sealant also was rapid, with about a 50% decrease in solid-phase ΣPAH8 concentration over the 45 days after application. There was general agreement, given the uncertainties, in the estimated mass of ΣPAH8 lost to the atmosphere on the basis of air sampling (2–3 g m-2) and adhered sealant sampling (6 g m-2) during the first 16 days after application, translating to a loss to the atmosphere of one-quarter to one-half of the PAHs in the sealcoat product. Combining the estimated mass of ΣPAH8 released to the atmosphere with a national-use estimate of coal-tar-based sealant suggests that PAH emissions from new coal-tar-based sealcoat applications each year (~1000 Mg) are larger than annual vehicle emissions of PAHs for the United States.

  16. 76 FR 59087 - Approval and Promulgation of Air Quality Implementation Plans; Delaware; Adhesives and Sealants Rule

    Science.gov (United States)

    2011-09-23

    ... Promulgation of Air Quality Implementation Plans; Delaware; Adhesives and Sealants Rule AGENCY: Environmental... manufacture, sale, use, or application of adhesives, sealants, primers, and solvents. This action is being... consists of Delaware's regulation for reducing VOCs from commercially-used adhesive and sealant products by...

  17. Do fibrin sealants impact negative outcomes after robot-assisted partial nephrectomy?

    Science.gov (United States)

    Cohen, Jason; Jayram, Gautam; Mullins, Jeffrey K; Ball, Mark W; Allaf, Mohamad E

    2013-10-01

    Contemporary rates of postoperative hemorrhage after partial nephrectomy (PN) are low. Commercially available hemostatic agents are commonly used during this surgery to reduce this risk despite a paucity of data supporting the practice. We assessed the impact of fibrin sealant hemostatic agents, a costly addition to surgeries, during robot-assisted partial nephrectomy (RAPN). Between 2007 and 2011, 114 consecutive patients underwent RAPN by a single surgeon (MEA). Evicel fibrin sealant was used in the first 74 patients during renorraphy. The last 40 patients had renorraphy performed without the use of any hemostatic agents. Clinicopathologic, operative, and complication data were compared between groups. Multivariate and univariate logistic regression analysis was performed to test the association between the use of fibrin sealants and operative outcomes. Patient demographic data and clinical tumor characteristics were similar between groups. The use of fibrin sealant did not increase operative time (166.3 vs 176.1 minutes, P=0.28), warm ischemia time (WIT) (14.4 vs 16.1 minutes, P=0.18), or length of hospital stay (2.6 vs 2.4 days, P=0.35). The omission of these agents did not increase estimated blood loss (116.6 vs 176.1 mL, P=0.8) or postoperative blood transfusion (0% vs 2.5%, P=0.17). Univariate analysis demonstrated no association between use of fibrin sealants and increased complications (P>0.05). Multivariable logistic regression showed no statistically significant predictive value of omission of hemostatic agents for perioperative outcomes (P>0.05). Perioperative hemorrhage and other major complications after contemporary RAPN are rare in experienced hands. In our study, the use of fibrin sealants during RAPN does not decrease the rate of complications, blood loss, or hospital stay. Furthermore, no impact is seen on operative time, WIT, or other negative outcomes. Omitting these agents during RAPN could be a safe, effective, cost-saving measure.

  18. Estimating emissions from adhesives and sealants uses and manufacturing for environmental risk assessments.

    Science.gov (United States)

    Tolls, Johannes; Gómez, Divina; Guhl, Walter; Funk, Torsten; Seger, Erich; Wind, Thorsten

    2016-01-01

    Regulation (EC) No 1907/2006 concerning the Registration, Evaluation, Authorisation and Restriction of Chemicals (REACH) requires that environmental exposure assessments be performed for all uses of dangerous substances that are marketed in the European Union in quantities above 10 tons per year. The quantification of emissions to the environment is a key step in this process. This publication describes the derivation of release factors and gives guidance for estimating use rates for quantifying the emissions from the manufacturing and application of adhesives and sealants. Release factors available for coatings and paints are read across to adhesives or sealants based on similarities between these 2 product groups with regard to chemical composition and to processing during manufacturing and application. The granular emission scenarios in these documents are mapped to the broad emission scenarios for adhesives or sealants. According to the mapping, the worst-case release factors for coatings or paints are identified and assigned to the adhesives or sealants scenarios. The resulting 10 specific environmental release categories (SPERCs) for adhesives and sealants are defined by differentiating between solvent and nonsolvent ingredients and between water-borne and solvent-borne or solvent-free products. These cover the vast majority of the production processes and uses and are more realistic than the 5 relevant emission estimation defaults provided in the REACH guidance. They are accompanied with adhesive or sealant consumption rates in the EU and with guidance for estimating conservative substance use rates at a generic level. The approach of combining conservative SPERC release factors with conservative estimates of substance rates is likely to yield emission estimates that tend to overpredict actual releases. Because this qualifies the approach for use in lower-tier environmental exposure assessment, the Association of the European Adhesive & Sealant Industry

  19. Retention of fissure sealants in young permanent molars affected by dental fluorosis: a 12-month clinical study.

    Science.gov (United States)

    Hasanuddin, S; Reddy, E R; Manjula, M; Srilaxmi, N; Rani, S T; Rajesh, A

    2014-10-01

    To evaluate and compare retention and caries occurance following placement of Clinpro and FUJI VII fissure sealants, by two different techniques simultaneously in unsealed, contralateral young permanent molars of 7- to 10-year-old children affected by mild to moderate dental fluorosis at various recall intervals of 1 week, 1, 3, 6 and 12 months. 80 schoolchildren with mild to moderate dental fluorosis were assigned to Group A and Group B with 40 children in each group. In Group A Clinpro fissure sealant and in Group B Fuji VII fissure sealant was used. In both the groups fissure sealants were applied by conventional fissure sealant technique (CST) on one side and enameloplasty sealant technique (EST) on the other side of the same arch. The applied fissure sealants were evaluated clinically for retention and caries incidence. Clinpro fissure sealant showed a retention rate of 95% when compared with Fuji VII (57.5%) at the end of 12 months, which was statistically significant. Regarding techniques, EST showed better results than CST in both the groups. Comparison of groups with respect to retention and techniques at different time periods was performed using Mann-Whitney U test (p < 0.05). Comparison of different time periods with respect to retention and technique in all the groups was performed using Wilcoxon matched pairs test by ranks (p < 0.05). Clinpro fissure sealant showed better retention at all treatment intervals, when compared with Fuji VII. Further follow-up is required to study the efficacy of the fissure sealant placement techniques.

  20. CDC Vital Signs–Dental Sealants Prevent Cavities

    Centers for Disease Control (CDC) Podcasts

    2016-10-18

    This podcast is based on the October 2016 CDC Vital Signs report. Dental sealants, applied soon after a child's permanent molars come in, can protect against cavities for up to nine years. Applying sealants in schools for low-income children could save millions in dental treatment costs.  Created: 10/18/2016 by National Center for Chronic Disease Prevention and Health Promotion (NCCDPHP).   Date Released: 10/18/2016.

  1. Caries detection methods : Can they aid decision making for invasive sealant treatment?

    NARCIS (Netherlands)

    Pereira, AC; Verdonschot, EH; Huysmans, M

    2001-01-01

    The decision to place sealants is a difficult one, and it has been suggested that in a low risk population it may be efficient to wait until caries is detected in the fissure. An invasive sealant technique with fissure preparation may then be indicated. The diagnostic method used in the indication

  2. Microtensile Bond Strength of Embrace Wetbond Hydrophilic Sealant in Different Moisture Contamination: An In-Vitro Study.

    Science.gov (United States)

    Panigrahi, Antarmayee; Srilatha, K T; Panigrahi, Rajat G; Mohanty, Susant; Bhuyan, Sanat K; Bardhan, Debojyoti

    2015-07-01

    Contamination of etched enamel with saliva has been shown to result in sealant failure. Recently, a hydrophilic sealant has been introduced. In absence of documented literature, this in vitro study was undertaken to ascertain the efficacy of Embrace Wet Bond without reduction of microtensile bond strength in the different moisture contamination. A 5mm block of sealant were built over prepared occlusal surface of 40 non-carious therapeutically extracted third molars which were sectioned into 1mm thick stick and tested using Zwick micro tensile tester. Obtained data were subjected to descriptive analysis, one-way ANOVA and Scheffe's post-hoc tests. Mean microtensile bond strength of Embrace sealant was not significantly lowered in different moisture contamination groups except Group 3 (air drying), which showed very highly significant (p<0.001) decrease in μTBS as compared to Group 1 (non-contaminated). Mean μTBS of Embrace sealant remains largely unchanged even in presence of moisture. Owing to its hydrophilic property, this sealant can be a great help in cases where maintaining isolation is difficult.

  3. Survival of sealants in molars affected by molar-incisor hypomineralization: 18-month follow-up

    Directory of Open Access Journals (Sweden)

    Camila Maria Bullio FRAGELLI

    2017-04-01

    Full Text Available Abstract The objective of this study was to evaluate the clinical survival of sealants applied in first permanent molars (FPMs affected by molar-incisor hypomineralization (MIH, at 18 months of follow-up. Forty-one first permanent molars were selected from 21 children, 6–8 years of age. MIH was classified by one calibrated examiner (kappa = 0.80 according to EAPD criteria. The inclusion criteria were fully erupted FPMs with MIH or sound FPMs (without MIH for which sealant treatment was indicated. The FPMs were assigned to two groups: CG (control group and HG (MIH group. Both groups were treated with sealant (FluroShield. Clinical follow-up was performed from baseline to 18 months to assess anatomical form, marginal adaptation, retention and presence of caries, according to criteria set by the United States Public Health Service-Modified, and was conducted by a blinded examiner (kappa = 0.80. The actuarial method was used to evaluate the survival of the sealants. The survival rates for the groups were compared using Fisher’s exact test (α = 5%. The cumulative survival rates were 81% at 1 month, 68.8% at 6 months, 68.8% at 12 months, and 62.6% at 18 months for CG, and 88% at 1 month, 84% at 6 months, 76% at 12 months, and 72% at 18 months for HG. No significant difference was found between the groups. The sealants in molars affected by MIH presented a survival rate similar to the sealants in the control, suggesting that sealants may be an adequate approach for preventing carious lesions in MIH-affected molars.

  4. Microleakage, adaptation ability and clinical efficacy of two fluoride releasing fissure sealants

    Directory of Open Access Journals (Sweden)

    Marković Dejan

    2012-01-01

    Full Text Available Background/Aim. Retention of fissure sealants and good adaptation to enamel are essential for their success. Fluoride releasing resin-based materials are widely accepted for pit and fissure sealing, but newly designed glass ionomers can serve as a good alternative. The aim of this study was to evaluate microleakage and sealing ability in vitro, and to clinically assess two fluoride releasing fissure sealants. Methods. The sample for experimental study consisted of 20 freshly extracted intact human third molars, divided in two experimental groups according to the sealing material: fluoride releasing resin-based (Heliosel F and glass ionomer (Fuji Triage material. Digital images and scanning electron microscope were used to assess microleakage and adaptation ability. Sample for clinical study consisted of 60 children, aged 6-8 years, with high caries risk, divided in two groups according to the sealant material. Fissure sealant was applied to all erupted, caries-free first permanent molars. Sealants were evaluated after 3, 6 and 12 months using modified Ryge criteria for retention, marginal adaptation, colour match, surface smoothness and caries. Results. Microleakage was detected in more than half of the specimen, without significant differences between the two groups (p > 0.05. Both materials exhibited acceptable sealing ability. Complete retention at the end of the observation period was 81.8% for resin-based, and 21.1% for glass-ionomer fissure sealant (p < 0.001. The presence of caries in sealed molars has been detected in one patient in both groups. During the 12-month observation period, Helioseal F demonstrated better retention, marginal adaptation and surface smoothness (p < 0.001. There were no differences between the two materials regarding caries and color match (p > 0.05. Conclusion. Both tested materials demonstrate satisfactory clinical and caries prophylactic characteristics that justify their use in contemporary preventive

  5. Comparison of various concentrations of tricalcium phosphate nanoparticles on mechanical properties and remineralization of fissure sealants.

    Directory of Open Access Journals (Sweden)

    Sara Tavassoli-Hojjati

    2014-08-01

    Full Text Available The aim of this study was to investigate the mechanical properties (flexural strength, micro-shear bond strength and remineralizing potential of fissure sealants by adding various concentrations of β-tricalcium phosphate nanoparticles.This in-vitro study consisted of five experimental groups containing prepared nano-fisssure sealants (1-5 wt.% β-TCP nanoparticles and two control groups containing a prepared and a commercial fissure sealant. Flexural/micro-shear bond strength values were measured using Zwick test machine. Cavities on sixty healthy premolar teeth were filled with the fissure sealants containing 0-5 wt.% of nano β-TCP. The samples were assessed for remineralization under scanning electron microscopy (SEM and EDAX. Kolmogorov-Smirnov test, One-way ANOVA and Tukey's Post Hoc analysis/HSD were used to analyze the data.There was no significant difference between the flexural strengths/elastic modulus of the 0-5 wt.% nano β-TCP groups (p>0.05. The average flexural strength/elastic modulus of the prepared fissure sealant group (0% was significantly higher than the commercial fissure sealant group (Clinpro (p0.05. Examining the samples under SEM showed a significant increase in thickness of the intermediate layer with increasing concentrations of β-TCP nanoparticles (p<0.05.Addition of 1-5 wt.% β-TCP nanoparticles to the fissure sealants significantly increased the remineralization potential without affecting the mechanical properties.

  6. Safety and usability of hemostats, sealants, and adhesives.

    Science.gov (United States)

    Burks, Sandra; Spotnitz, William

    2014-08-01

    Hemostats, sealants, and adhesives are an integral part of surgical patient care. Nurses who have knowledge about these agents can better help ensure safe, efficient surgical patient care. As a caregiver and patient advocate, the perioperative nurse must understand the most current information about these agents and be prepared to facilitate the transfer of this knowledge to all caregivers. Information about these agents, including the contraindications, warnings, and precautions associated with their use as well as their preparation and application, is provided here. Algorithms designed to clarify the best options for using hemostats, sealants, and adhesives are included as well. Copyright © 2014 AORN, Inc. Published by Elsevier Inc. All rights reserved.

  7. [Eosinophilic pleural effusion possibly induced by fibrin sealant].

    Science.gov (United States)

    Kambayashi, Takatoyo; Suzuki, Takashi

    2012-02-01

    A 74-year-old man underwent right upper lobectomy for the lung cancer and bullectomy of right lower lobe. Fibrin sealant was used for sealing the excision line. The increase of the pleural effusion with increasing C-reactive protein( CRP) and eosinophilia was noted at the 17th day after the operation. The pleural effusion was transparent and yellowish colored suggesting transudatory liquid. The eosinophil in the pleural effusion was as high as 14%. The drainage of the pleural effusion was performed for 2 days resulting in disappearing the abnormal accumulation without any additional treatment. The cause of pleural effusion was supposed to be fibrin sealant by a positive result of the drug lymphocyte stimulation test.

  8. Evaluation of strategies to communicate harmful and potentially harmful constituent (HPHC) information through cigarette package inserts: a discrete choice experiment.

    Science.gov (United States)

    Salloum, Ramzi G; Louviere, Jordan J; Getz, Kayla R; Islam, Farahnaz; Anshari, Dien; Cho, Yoojin; O'Connor, Richard J; Hammond, David; Thrasher, James F

    2017-07-13

    The US Food and Drug Administration (FDA) has regulatory authority to use inserts to communicate with consumers about harmful and potentially harmful constituents (HPHCs) in tobacco products; however, little is known about the most effective manner for presenting HPHC information. In a discrete choice experiment, participants evaluated eight choice sets, each of which showed two cigarette packages from four different brands and tar levels (high vs low), accompanied by an insert that included between-subject manipulations (ie, listing of HPHCs vs grouping by disease outcome and numeric values ascribed to HPHCs vs no numbers) and within-subject manipulations (ie, 1 of 4 warning topics; statement linking an HPHC with disease vs statement with no HPHC link). For each choice set, participants were asked: (1) which package is more harmful and (2) which motivates them to not smoke; each with a 'no difference' option. Alternative-specific logit models regressed choice on attribute levels. 1212 participants were recruited from an online consumer panel (725 18-29-year-old smokers and susceptible non-smokers and 487 30-64-year-old smokers). Participants were more likely to endorse high-tar products as more harmful than low-tar products, with a greater effect when numeric HPHC information was present. Compared with a simple warning statement, the statement linking HPHCs with disease encouraged quit motivation. Numeric HPHC information on inserts appears to produce misunderstandings that some cigarettes are less harmful than others. Furthermore, brief narratives that link HPHCs to smoking-related disease may promote cessation versus communications that do not explicitly link HPHCs to disease. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2017. All rights reserved. No commercial use is permitted unless otherwise expressly granted.

  9. Clinical and SEM assessment of ART high-viscosity glass-ionomer sealants after 8-13 years in 4 teeth.

    NARCIS (Netherlands)

    Frencken, J.E.F.M.; Wolke, J.G.C.

    2010-01-01

    OBJECTIVES: Resin composite sealants are retained longer than low-viscosity glass-ionomer sealants. Nevertheless, a systematic review showed that there is no evidence that resin composite sealants are superior to low-viscosity glass-ionomers in preventing dentine carious lesion development. This

  10. Causes of poor sealant performance in soil-gas-resistant foundations

    International Nuclear Information System (INIS)

    Scott, A.

    1994-01-01

    Sealants for radon-resistant foundation construction must seal the gap between concrete sections. Modern sealants have such low permeability that seal performance depends only on the permeability of the material that contacts the sealant. The surface permeability of concrete walls and floors was measured by a specially designed permeameter, which measures the airflow induced by a pressure difference across a temporary test seal applied to the surface. The permeability of bulk concrete is about 10 -15 m 2 . Areas free of surface defects had surface permeability ranging from 10 -14 to 10 -16 m 2 . However, surface defects are common on concrete wall surfaces, which increase the permeability to >10 -12 m 2 , too high for standard seal designs to be adequate as the only method of soil gas and radon exclusion. Radon-resistant seals require either extended contact widths or mechanical removal of the surface layer and defects. (au) (4 refs.)

  11. Bisphenol A in dental sealants and its estrogen like effect

    Directory of Open Access Journals (Sweden)

    Manu Rathee

    2012-01-01

    Full Text Available Bisphenol A or BPA-based epoxy resins are widely used in the manufacture of commercial products, including dental resins, polycarbonate plastics, and the inner coating of food cans. BPA is a precursor to the resin monomer Bis-GMA. During the manufacturing process of Bis-GMA dental sealants, Bisphenol A (BPA might be present as an impurity or as a degradation product of Bis-DMA through esterases present in saliva. Leaching of these monomers from resins can occur during the initial setting period and in conjunction with fluid sorption and desorption over time and this chemical leach from dental sealants may be bioactive. Researchers found an estrogenic effect with BPA, Bis-DMA, and Bis-GMA because BPA lacks structural specificity as a natural ligand to the estrogen receptor. It generated considerable concern regarding the safety of dental resin materials. This review focuses on the BPA in dental sealants and its estrogen-like effect.

  12. Watermarking spot colors in packaging

    Science.gov (United States)

    Reed, Alastair; Filler, TomáÅ.¡; Falkenstern, Kristyn; Bai, Yang

    2015-03-01

    In January 2014, Digimarc announced Digimarc® Barcode for the packaging industry to improve the check-out efficiency and customer experience for retailers. Digimarc Barcode is a machine readable code that carries the same information as a traditional Universal Product Code (UPC) and is introduced by adding a robust digital watermark to the package design. It is imperceptible to the human eye but can be read by a modern barcode scanner at the Point of Sale (POS) station. Compared to a traditional linear barcode, Digimarc Barcode covers the whole package with minimal impact on the graphic design. This significantly improves the Items per Minute (IPM) metric, which retailers use to track the checkout efficiency since it closely relates to their profitability. Increasing IPM by a few percent could lead to potential savings of millions of dollars for retailers, giving them a strong incentive to add the Digimarc Barcode to their packages. Testing performed by Digimarc showed increases in IPM of at least 33% using the Digimarc Barcode, compared to using a traditional barcode. A method of watermarking print ready image data used in the commercial packaging industry is described. A significant proportion of packages are printed using spot colors, therefore spot colors needs to be supported by an embedder for Digimarc Barcode. Digimarc Barcode supports the PANTONE spot color system, which is commonly used in the packaging industry. The Digimarc Barcode embedder allows a user to insert the UPC code in an image while minimizing perceptibility to the Human Visual System (HVS). The Digimarc Barcode is inserted in the printing ink domain, using an Adobe Photoshop plug-in as the last step before printing. Since Photoshop is an industry standard widely used by pre-press shops in the packaging industry, a Digimarc Barcode can be easily inserted and proofed.

  13. Low-cost glass ionomer cement as ART sealant in permanent molars: a randomized clinical trial

    Directory of Open Access Journals (Sweden)

    Daniela HESSE

    2015-01-01

    Full Text Available Clinical trials are normally performed with well-known brands of glass ionomer cement (GIC, but the cost of these materials is high for public healthcare in less-affluent communities. Given the need to research cheaper materials, it seems pertinent to investigate the retention rate of a low-cost GIC applied as atraumatic restorative treatment (ART sealants in two centers in Brazil. Four hundred and thirty-seven 6-to-8-year-old schoolchildren were selected in two cities in Brazil. The children were randomly divided into two groups, according to the tested GIC applied in the first permanent molars. The retention rate was evaluated after 3, 6 and 12 months. Kaplan-Meier survival analysis and the log-rank test were performed. The variables were tested for association with sealant longevity, using logistic regression analyses (α = 5%. The retention rate of sealants after 12 months was 19.1%. The high-cost GIC brand presented a 2-fold-more-likely-to-survive rate than the low-cost brand (p < 0.001. Significant difference was also found between the cities where the treatments were performed, in that Barueri presented a higher sealant survival rate than Recife (p < 0.001. The retention rate of a low-cost GIC sealant brand was markedly lower than that of a well-known GIC sealant brand.

  14. Hemostats, sealants, and adhesives: components of the surgical toolbox.

    Science.gov (United States)

    Spotnitz, William D; Burks, Sandra

    2008-07-01

    The surgical toolbox is expanding, and newer products are being developed to improve results. Reducing blood loss so that bloodless surgery can be performed may help minimize morbidity and length of stay. As patients, hospital administrators, and government regulators desire less invasive procedures, the surgical technical challenge is increasing. More operations are being performed through minimally invasive incisions with laparoscopic, endoscopic, and robotic approaches. In this setting, tools that can reduce bleeding by causing blood to clot, sealing vessels, or gluing tissues are gaining an increasing importance. Thus, hemostats, sealants, and adhesives are becoming a more important element of surgical practice. This review is designed to facilitate the reader's basic knowledge of these tools so that informed choices are made for controlling bleeding in specific clinical situations. Such information is useful for all members of the operative team. The team includes surgeons, anesthesiologists, residents, and nurses as well as hematologists and other medical specialists who may be involved in the perioperative care of surgical patients. An understanding of these therapeutic options may also be helpful to the transfusion service. In some cases, these materials may be stored in the blood bank, and their appropriate use may reduce demand for other transfusion components. The product classification used in this review includes hemostats as represented by product categories that include mechanical agents, active agents, flowables, and fibrin sealants; sealants as represented by fibrin sealants and polyethylene glycol hydrogels; and adhesives as represented by cyanoacrylates and albumin cross-linked with glutaraldehyde. Only those agents approved by the Food and Drug Administration (FDA) and presently available (February 2008) for sale in the United States are discussed in this review.

  15. Percutaneous treatment of femoral pseudoaneurysms: comparison of fibrin sealant against thrombin

    Directory of Open Access Journals (Sweden)

    Daniel Mendes Pinto

    2013-12-01

    Full Text Available INTRODUCTION: Femoral pseudoaneurysms are a complication that occurs in connection with up to 8% of percutaneous procedures. Of the available treatments, ultrasound guided thrombin injection has a high success rate and is well-tolerated by patients. The combination of thrombin and fibrinogen known as fibrin sealant forms a stable clot and can be used to treat pseudoaneurysms, particularly those with complex anatomy and larger size. OBJECTIVE: To compare the results of treating femoral pseudoaneurysm in two ways: Group T was treated with thrombin alone and Group T+F was treated with fibrin sealant (thrombin+fibrinogen. METHODS: A retrospective analysis was conducted of femoral pseudoaneurysm cases treated between January 2005 and December 2012. RESULTS: Twenty-eight patients were treated, 21 with thrombin alone and seven with fibrin sealant. All patients in group T were treated successfully, but only four patients in group T+F were treated successfully (57.1% success rate in Group T+F, p<0.01. The three cases of failure in group T+F needed surgery and in one of these cases the complication was embolization to the femoral bifurcation. The pseudoaneurysms that were treated with fibrin sealant were larger (25 cm3 in Group T and 57.7 cm3 in Group T+F, p=0.02 and required larger volumes of thrombin (0.5 mL in Group T and 1.0 mL in Group T+F, p<0.01. There was one complication in Group T and two complications in Group T+F (p<0.01. CONCLUSIONS: Irrespective of the small number of cases reviewed, treatment with thrombin alone was superior to treating with fibrin sealant, since it caused few complications and was more effective at correcting pseudoaneurysms.

  16. A Trajectory Generation Method Based on Edge Detection for Auto-Sealant Cartesian Robot

    Directory of Open Access Journals (Sweden)

    Eka Samsul Maarif

    2014-07-01

    Full Text Available This paper presents algorithm ingenerating trajectory for sealant process using captured image. Cartesian robot as auto-sealant in manufacturing process has increased productivity, reduces human error and saves time. But, different sealant path in many engine models means not only different trajectory but also different program. Therefore robot with detection ability to generate its own trajectory is needed. This paper describes best lighting technique in capturing image and applies edge detection in trajectory generation as the solution. The algorithm comprises image capturing, Canny edge detection, integral projection in localizing outer most edge, scanning coordinates, and generating vector direction codes. The experiment results show that the best technique is diffuse lighting at 10 Cd. The developed method gives connected point to point trajectory which forms sealant path with a point to next point distance is equal to 90° motor rotation. Directional movement for point to point trajectory is controlled by generated codes which are ready to be sent by serial communication to robot controller as instruction for motors which actuate axes X and Y directions.

  17. Evaluation of package inserts of Ayurveda drug formulations from Mumbai city.

    Science.gov (United States)

    Shirolkar, Sudatta; Tripathi, Raakhi K; Potey, Anirudha V

    2015-01-01

    Package insert (PI) is a vital document accompanying a prescribed medication to provide information to the prescriber and end-user at a glance. Studies regarding PIs of Ayurvedic medicines in accordance with standard guidelines are lacking. Present study was undertaken to evaluate PI of Ayurveda drugs. PIs of Ayurveda drugs were obtained from five randomly selected Ayurveda medical shops located in three main zones of Mumbai. From each medical shop, a range of 15-20 PI was planned to be collected for different formulations. It was decided to collect a minimum fifty PIs/group for equitable distribution of various formulations in period of January-June2013. Checklist was prepared, and content validity was achieved. Final validated checklist contained a total of 13 items, and the presence or absence of information pertaining to these items on the PI was evaluated. Any other additional information present on PI was also noted. Each item was analyzed and expressed as percentages. The information on 258 PIs included: Name of ingredients (67%), quantity of ingredients (47.27%), route of administration (86.8%), dosage form (86.8%), indications (18%), dose (18%), contraindications (18%), side effects (9%), shelf life (5.81%), storage conditions (11%), and manufacturers name with contact details (34%). PIs accompanying Ayurveda medicinal products in India are deficient in information required to be furnished by them.

  18. An accelerated exposure and testing apparatus for building joint sealants.

    Science.gov (United States)

    White, C C; Hunston, D L; Tan, K T; Hettenhouser, J; Garver, J D

    2013-09-01

    The design, fabrication, and implementation of a computer-controlled exposure and testing apparatus for building joint sealants are described in this paper. This apparatus is unique in its ability to independently control and monitor temperature, relative humidity, ultraviolet (UV) radiation, and mechanical deformation. Each of these environmental factors can be controlled precisely over a wide range of conditions during periods of a month or more. Moreover, as controlled mechanical deformations can be generated, in situ mechanical characterization tests can be performed without removing specimens from the chamber. Temperature and humidity were controlled during our experiments via a precision temperature regulator and proportional mixing of dry and moisture-saturated air; while highly uniform UV radiation was attained by attaching the chamber to an integrating sphere-based radiation source. A computer-controlled stepper motor and a transmission system were used to provide precise movement control. The reliability and effectiveness of the apparatus were demonstrated on a model sealant material. The results clearly show that this apparatus provides an excellent platform to study the long-term durability of building joint sealants.

  19. Effectiveness of a new gelatin sealant system for dural closure.

    Science.gov (United States)

    Kawai, Hisashi; Nakagawa, Ichiro; Nishimura, Fumihiko; Motoyama, Yasushi; Park, Young-Su; Nakamura, Mitsutoshi; Nakase, Hiroyuki; Suzuki, Shuko; Ikada, Yoshito

    2014-10-01

    Watertight dural closure is imperative after neurosurgical procedures because inadequately treated leakage of cerebrospinal fluid (CSF) can have serious consequences. In this study, the authors test the use of a new gelatin glue as a dural sealant in in vitro and in vivo canine models of transdural CSF leakage. The in vitro model was sutured semicircles of canine dura mater and artificial dural substitute. The sutures were sealed with gelatin glue (n  =  20), fibrin glue (n  =  20), or a polyethylene glycol (PEG)-based hydrogel sealant (n  =  20). Each sample was set in a device to measure water pressure, and pressure was increased until leakage occurred. Bonding strength was subjectively evaluated. The in vivo model was dogs who underwent dural excision and received either no sealant (control group; n  =  5) or gelatin glue sealant (n  =  5) before dural closure. Twenty-eight days post-surgery, the maximum intracranial pressure was measured at the cisterna magna using Valsalva maneuver and tissue adhesion was evaluated. The water pressure at which leakage occurred in the in vitro model was higher with gelatin glue (76·5 ± 39·8 mmHg) than with fibrin glue (38·3 ± 27·4 mmHg, P control group (13·8 ± 4·0 mmHg, P control group (P  =  0·005). The new gelatin glue provides an effective watertight closure when used as an adjunct to sutured dural repair.

  20. Comparative efficacy of nanofilled and microfilled resin-modified glass ionomer as pits and fissure sealant in permanent molar teeth

    Directory of Open Access Journals (Sweden)

    Manzuma Akhter Zakaria

    2017-05-01

    Full Text Available The purpose of the present study was to compare the efficacy of nanofilled and microfilled resin- modified glass ionomer as pits and fissure sealants in permanent molar teeth. Ninety six teeth having fissure at the occlusal surface were randomly divided into two groups: Group I: Treated by nanofilled resin-modified glass ionomer sealant and Group II: Treated by microfilled resin- modified glass ionomer sealants. Clinical assessment was performed by modified Ryge´s criteria by means of retention, color match, marginal adaptation at 3, 6, and 12 months follow-up visit. Chi-square test was used for testing differences between the two groups; a value of p<0.05 was considered as statistically significant. The results revealed that at 12 months observation period, nanofilled resin-modified glass ionomer sealant showed better retention, color stability and marginal adaptation than that of microfilled resin-modified glass ionomer sealants. Furthermore, the differences between two groups in respect to marginal adaptation and color match were statistically significant (p<0.05. It can be concluded that nanofilled resin-modified glass ionomer sealant could be a better alternative to microfilled resin- modified glass ionomer sealant.

  1. Do package inserts reflect symptoms experienced in practice?: assessment using an automated phone pharmacovigilance system with varenicline and zolpidem in a primary care setting.

    Science.gov (United States)

    Haas, Jennifer S; Amato, Mary; Marinacci, Lucas; Orav, E John; Schiff, Gordon D; Bates, David W

    2012-08-01

    While the US FDA maintains a voluntary reporting system, postmarketing adverse drug events (ADEs) are underreported, and this case report-based system does not allow accurate determination of incidence. The aim of the study was to assess the usefulness of an automated phone pharmacovigilance system for ambulatory patients by comparing systematically collected, patient-reported symptoms to reflect possible ADEs with those reported on the package inserts of two drugs with postmarketing safety concerns, varenicline and zolpidem. English-speaking adults who received a prescription for zolpidem (n = 370) or varenicline (n = 107) from a primary care physician at one of 11 participating clinics, and who participated in the pharmacovigilance system during 2008-2010, were included in the study. Patients were called approximately 4 weeks following their visit and asked to complete a standard script that asked about adherence and pre-specified symptoms. The main outcome measures were elicited rates of pre-specified symptoms or possible ADEs. Compared with the package insert, patients taking zolpidem were significantly (p zolpidem were not detected. These data highlight the potential value of, and innovative ways of collecting, information about possible ADEs directly from patients.

  2. Microleakage assessment of fissure sealant following fissurotomy bur or pumice prophylaxis use before etching

    Directory of Open Access Journals (Sweden)

    Ali Bagherian

    2013-01-01

    The aim of this investigation was to compare the microleakage level of fissure sealants prepared by a fissurotomy bur or pumice prophylaxis prior to acid etching. Materials and Methods: Ninety freshly extracted healthy maxillary premolar teeth were randomly selected for this investigation. Teeth were then divided into three fissure sealant preparatory groups of A: Fissurotomy bur + acid etch; B: Pumice prophylaxis + acid etch and C: Acid etch alone. Sealant was applied to the occlusal fissures of all specimens using a plastic instrument. This was to avoid any air trap under the sealant. Sample teeth were first thermocycled (1000 cycles, 20 s dwell time and then coated with two layers of nail varnish leaving 2 mm around the sealant. This was then followed by immersion in basic fuchsin 3%. Processed teeth were sectioned longitudinally and examined under a stereomicroscope for microleakage assessment using a score of 0-3. Collected data was then subjected to Kruskall-Wallis Analysis of Variance and Mann-Whitney U-test. P < 0.05 was considered as significant. Results: Teeth in fissurotomy bur and pumice prophylaxis groups had significantly reduced level of microleakage than those in acid etch alone (P = 0.005 and P = 0.003, respectively. Conclusion: Use of fissurotomy bur and pumice prophylaxis accompanied with acid etching appears to have a more successful reduction of microleakage than acid etch alone.

  3. Retention of fissure sealants using two different methods of application in teeth with hypomineralised molars (MIH): a 4 year clinical study.

    Science.gov (United States)

    Lygidakis, N A; Dimou, G; Stamataki, E

    2009-12-01

    This was to evaluate the retention rate of fissure sealants applied to MIH molars with occlusal enamel opacities, using two different application methods after 4 years. 54 children exhibiting molars with MIH aged 6-7 years, participated in the study. presence of at least 2 fully erupted caries-free maxillary or mandibular first permanent molars in the opposite sides of the mouth, both with occlusal enamel opacities without breakdown. Following parental consent, sealants were applied using a half-mouth experimental design. Group A: On a randomly assigned first molar on one side of the mouth sealants Fissurit were placed using a single bottle adhesive system (One-step prior to sealant application. Group B: Sealants were applied on the contra-lateral molar using the conventional etch and seal technique. Children were seen biannually when a preventive program was applied, without replacing any lost sealant. After 4 years, 47 sets of molars (94 teeth) were available for blind evaluation. Teeth in Group A presented a better retention rate; 70.2% were fully sealed, 29.7% partly sealed and none unsealed (lost sealant). Group B revealed 25.5% fully sealed, 44.6% partly sealed and 29.7% unsealed teeth. Differences between groups A and B were statistically significant (p0.01). In hypomineralised molars with occlusal opacities sealants appear to have greater retention when applied using 5th generation adhesive systems prior to sealant.

  4. Bond Strength of a Bisphenol-A-Free Fissure Sealant With and Without Adhesive Layer under Conditions of Saliva Contamination.

    Science.gov (United States)

    Mesquita-Guimarães, Késsia Suênia Fidelis de; Sabbatini, Iliana Ferraz; Almeida, Cintia Guimarães de; Galo, Rodrigo; Nelson-Filho, Paulo; Borsatto, Maria Cristina

    2016-01-01

    Dental sealants are important for prevention of carious lesions, if they have good shear strength. The aim of this study was to evaluate the shear bond strength (SBS) of two sealants to saliva-contaminated and non-contaminated enamel with and without an intermediate adhesive layer underneath the sealant. Ninety flat enamel surfaces from human third molars were randomly assigned to 6 groups (n=15): F (control): Fluroshield(tm) sealant; EWB (control): Embrace(tm) WetBond(tm); SB/F: Single Bond adhesive system + F; SB/EWB, s-SB/F and s-SB/EWB. In the s-SB/F and s-SB/EWB groups, the acid-etched enamel was contaminated with 0.01 mL of fresh human saliva for 20 s. Sealant cylinders were bonded to enamel surface with and without an intermediate adhesive system layer. The shear tests were performed using a universal testing machine (0.5 mm/min). Data were analyzed statistically by Kruskal-Wallis and Mann-Whitney tests (α=0.05). F presented higher mean SBS than EWB in all experimental conditions. The lowest SBS mean was obtained for EWB on contaminated enamel (p<0.05). In conclusion, an adhesive system layer should be used prior to sealant placement, in both dry and saliva-contaminated enamel. F had the best performance in all experimental conditions. EWB sealant showed very low results, but an adhesive layer underneath the sealant increased its SBS even after salivary contamination.

  5. Use of fibrin sealants for the localized, controlled release of cefazolin

    Science.gov (United States)

    Tredwell, Stephen; Jackson, John K.; Hamilton, Donald; Lee, Vivian; Burt, Helen M.

    2006-01-01

    Background Fibrin sealants are used increasingly in surgery to reduce bleeding and improve wound healing. They have great potential as biocompatible, biodegradable drug delivery systems, because the sealant may adhere to the target tissue and allow controlled release of the drug over an extended period. We investigated the encapsulation, stability and controlled release of erythromycin and cefazolin from Beriplast fibrin sealants (Aventis Behring Canada). Methods Drug-loaded clots were cast in glass vials and allowed to set. We observed the clots for drug precipitation and aggregation, and we assessed the effect of drug encapsulation on clot strength. Drug stability and release from the clots in phosphate buffered saline (PBS) was quantified by ultraviolet and visible violet absorbance spectroscopy and high-performance liquid chromatography. Results Erythromycin was found to release slowly from the fibrin clots over the first 2 hours but then degrade rapidly. Cefazolin was found to be very stable in clots in PBS (97% stable at 2 d and 93% stable at 5 d). The drug released in a controlled manner over 2 days, with most being released during the first day. The dose of drug released could be varied by changing the amount placed in the thrombin solution. Clot thickness had no effect on the rate of cefazolin release. Conclusion Overall, the 2-day release profile and the excellent stability of the drug suggest that cefazolin-loaded fibrin sealants may offer an effective route of postoperative antibiotic delivery. PMID:17152573

  6. Comparison of a plasma-based composite biologic sealant with fibrin glue (Tisseel) for vascular anastomoses.

    Science.gov (United States)

    Doillon, Charles J; Dion, Yves-Marie

    2004-12-01

    Biologic sealants are needed in numerous, more and more demanding, procedures--especially with developments occurring in endovascular and laparoscopic vascular techniques. An initial pilot study in dogs showed that a 4-cm aortotomy closed with a polyester patch sutured in place by a 4-mm-spaced running suture consistently led to massive hemorrhage. We then designed a study using five dogs where two aortotomies were done to compare the effect of Tisseel to that of an autologous sealant prepared in our laboratory. Arterial pressures and heparinization were maintained throughout the surgical procedure. Both biologic sealants prevented hemorrhage from the arteriotomy at unclamping. Macroscopic and histologic assessments were performed. At killing, one week later, the autologous sealant exhibited less blood saturation of the collagen sponge compared with Tisseel. The use of autologous plasma combined with other adhesive components could be an efficient alternative to allogenic fibrin glue. Further studies are needed to confirm these observations.

  7. Comprehensive Die Shear Test of Silicon Packages Bonded by Thermocompression of Al Layers with Thin Sn Capping or Insertions

    Directory of Open Access Journals (Sweden)

    Shiro Satoh

    2018-04-01

    Full Text Available Thermocompression bonding for wafer-level hermetic packaging was demonstrated at the lowest temperature of 370 to 390 °C ever reported using Al films with thin Sn capping or insertions as bonding layer. For shrinking the chip size of MEMS (micro electro mechanical systems, a smaller size of wafer-level packaging and MEMS–ASIC (application specific integrated circuit integration are of great importance. Metal-based bonding under the temperature of CMOS (complementary metal-oxide-semiconductor backend process is a key technology, and Al is one of the best candidates for bonding metal in terms of CMOS compatibility. In this study, after the thermocompression bonding of two substrates, the shear fracture strength of dies was measured by a bonding tester, and the shear-fractured surfaces were observed by SEM (scanning electron microscope, EDX (energy dispersive X-ray spectrometry, and a surface profiler to clarify where the shear fracture took place. We confirmed two kinds of fracture mode. One mode is Si bulk fracture mode, where the die shear strength is 41.6 to 209 MPa, proportionally depending on the area of Si fracture. The other mode is bonding interface fracture mode, where the die shear strength is 32.8 to 97.4 MPa. Regardless of the fracture modes, the minimum die shear strength is practical for wafer-level MEMS packaging.

  8. 76 FR 79537 - Approval and Promulgation of Air Quality Implementation Plans; Delaware; Adhesives and Sealants Rule

    Science.gov (United States)

    2011-12-22

    ... Promulgation of Air Quality Implementation Plans; Delaware; Adhesives and Sealants Rule AGENCY: Environmental..., sale, use, or application of adhesives, sealants, primers, and solvents. EPA is approving this SIP... miscellaneous industrial adhesives control techniques guideline (CTG) category in accordance with the...

  9. ART restorations and sealants placed in Chinese school children--results after three years.

    Science.gov (United States)

    Holmgren, C J; Lo, E C; Hu, D; Wan, H

    2000-08-01

    These were to assess whether ART restorations and sealants could be provided to children in a school environment in China, to assess patient acceptability of the ART approach, and to evaluate on a longitudinal basis the treatments performed. This study was conducted in Deyang, Sichuan Province, in western China. A total of 294 ART restorations were placed in 197 children and 191 fissure sealants were placed in 140 children by five middle-level dentists in four secondary schools. Standard instruments and procedures for ART were used. The restorative material used was a high-strength glass-ionomer (Ketac-Molar, ESPE). The treatments were evaluated annually after placement by the same examiner who had not been involved in the placement of the restorations nor sealants using explorers and mouth-mirrors. At the 3-year examination an independent external examiner evaluated the restorations using USPHS criteria. Most of the children did not report discomfort during treatment and 92% were willing to receive ART restorations again. The cumulative 1-year and 3-year survival rates of small Class I restorations were 99% and 92% respectively. The corresponding figures for large Class I restorations were 90% and 77%. After 3 years, 72% of the sealants were either partially or completely retained. Only 2% of the sealed teeth developed fissure caries and these involved teeth where the sealants had been lost. Similar success rates were found using USPHS criteria. The ART approach for preventing and treating tooth decay in Chinese school children was shown to be appropriate, effective and acceptable. The 3-year survival rates of the restorations were high but were related to the size and type of the restoration.

  10. Polychlorinated biphenyls in polysulfide sealants-Occurrence and emission from a landfill station

    International Nuclear Information System (INIS)

    Persson, N. Johan; Pettersen, Harald; Ishaq, Rasha; Axelman, Johan; Bandh, Cecilia; Broman, Dag; Zebuehr, Yngve; Hammar, Tommy

    2005-01-01

    Approximately 80 000 kg polysulfide sealant containing 10 000-18 000 kg polychlorinated biphenyls (PCB) was deposited at a Swedish municipal landfill station during 1965-1973. Investigations during 1994 showed that soil layers underneath the landfill had concentration of PCB not alarmingly high. The concentration of PCB congeners in ground water samples was elevated 4-750 times compared to a reference sample. Based on samples of ground water, leachate water, and flux chambers measuring evaporation of PCB from the landfill surface, the emission of PCB was estimated to be 1 g ΣPCB/yr. This very low rate was attributed to the high sorptive capacity of the sealant. Compared to a reference site, the evaporation flux was elevated for the most volatile congeners, but factors 20-1400 lower than from another landfill which was contaminated with PCB in paper-pulp fibres. - From a municipal 2-ha landfill containing 10-18 tonnes of ΣPCB bound in polysulfide sealants, only 1 g per year escape to the surroundings

  11. Comparison of commercial fibrin sealants in facelift surgery: a prospective study

    Directory of Open Access Journals (Sweden)

    Botti G

    2013-11-01

    Full Text Available Giovanni Botti,1 Michele Pascali,2 Chiara Botti,1 Florian Bodog,3 Pietro Gentile,2 Valerio Cervelli2 1Villa Bella Clinic, Salò, 2Department of Plastic and Reconstructive Surgery, University of Rome Tor Vergata, Italy; 3University of Oradea, Oradea, Romania Background: The aim of this study was to compare the effects of two types of fibrin glue in patients undergoing facelift surgery. Methods: A prospective, controlled "right-left side" study was carried out in 20 patients. The two fibrin sealants used were Quixil® and Tissucol®. The two sealants were used at the same time, ie, one on one side of the face and the other on the contralateral side. Comparisons were made with regard to rates of hematoma and seroma, degree of induration, edema, ecchymosis, pain levels, and patient satisfaction. Results: The results were almost equivalent. The only exception was a significant (40 mL hematoma in a patient treated with Quixil. Bleeding was most likely due to a sudden rise in blood pressure during the immediate postoperative period. However, it must be emphasized that, while Tissucol actually seals the undermined area, thus virtually eliminating the dead space, Quixil acts differently, in that its effectiveness in preventing hematoma is linked mainly to its hemostatic effect. Conclusion: The two fibrin sealants used were nearly identical with regard to patient safety and quality of the result. Nevertheless, it is noted that, while Tissucol has both hemostatic and "gluing" effects, Quixil is mainly effective in securing hemostasis. Keywords: facelift surgery, rhytidectomy, fibrin sealants, hematoma

  12. Leak tight sealants and joint details for concrete structure in RAPP

    International Nuclear Information System (INIS)

    Singha Roy, P.K.; Baste, M.S.

    1975-01-01

    Leak tightness may pertain to either air or water and in extreme cases each will require separate consideration based on general basic requirements. Leak-tight sealants against air pressure are required in the construction joints and around penetrations in the concrete containment structures. The containment structures should be able to withstand the maximum anticipated design pressure during the incident of a MCA with only minimal leakage (0.1% of bldg. volume per day in RAPP) which is mostly through these joints. Apart from proper joint design and preparation the sealant itself must have superb adhesion to the concrete surface and integrify throughout its service life to prevent any rupture or micro-cracks at any section of the joint. Leak tightness pertains to water tightness as well. A critical water-tight joint at the bottom dome of the prestressed concrete dousing tank at its junction with the 36 inches dia dousing water pipes constructed in RAPP-2, which should be able to withstand the water pressure, continuous submergence in the water of the tank and the longitudinal and lateral movement of the water pipes during opening and closure of the dousing valves, has been made and hydrostatically tested when not even the slight sweating was found. The construction and materials of the above joints and the sealant along with the properties and performance observed during testing/use are described. As the sealant used is an imported poly-sulphide caulking compound suggestions have also been made, which may be kept in mind while developing an Indian substitute. (author)

  13. 76 FR 64237 - Approval and Promulgation of Air Quality Implementation Plans; Maryland; Adhesives and Sealants Rule

    Science.gov (United States)

    2011-10-18

    ...-9480-5] Approval and Promulgation of Air Quality Implementation Plans; Maryland; Adhesives and Sealants... chemical production and polytetrafluoroethylene operations; from paint, resin, and adhesive manufacturing; and from adhesive and sealant application. This SIP revision also pertains to an addition of a new...

  14. A reversible thermoresponsive sealant for temporary closure of ocular trauma.

    Science.gov (United States)

    Bayat, Niki; Zhang, Yi; Falabella, Paulo; Menefee, Roby; Whalen, John J; Humayun, Mark S; Thompson, Mark E

    2017-12-06

    Open globe injuries are full-thickness injuries sustained to the eye wall (cornea or sclera), which cause immediate drops in intraocular pressure that may lead to retinal detachment and permanent vision loss if not treated rapidly after injury. The current standard of care for open globe injuries consists of suturing the margins closed, but the technique can be time-consuming, requires specialized training and equipment, and can lead to patient discomfort, abrasion, and infection from eye rubbing. We engineered an injectable, thermoresponsive sealant (TRS) and a custom tool to occlude open globe injuries. The smart hydrogel sealant consists of physically cross-linked N -isopropylacrylamide copolymerized with butylacrylate. At low temperatures, it can be injected as a liquid, and when raised to body temperature, a heat-induced gelation converts the hydrogel into a solidified occlusion. The sealant can be repositioned or removed without causing additional trauma via exposure to cold water. In vitro and ex vivo assessments of mechanical adhesion to eye tissue revealed maintenance of intraocular pressure that is five times greater than the physiological range with reversible seal strength comparable to cyanoacrylate (super glue). In vivo assessment in a rabbit model of ocular trauma demonstrated ease of use for TRS deployment, statistically significant improvement in wound sealing, and no evidence of neurotoxicity, retinal tissue degradation, or significant chronic inflammatory response after 30 days of exposure. Given the advantages of body heat-induced gelation, rapid reversible occlusion, and in vivo safety and efficacy, shape-adaptable TRSs have translational potential as smart wound sealants for temporary occlusion of surgical incisions or traumatic injuries. Copyright © 2017 The Authors, some rights reserved; exclusive licensee American Association for the Advancement of Science. No claim to original U.S. Government Works.

  15. Attitudes of consumers and healthcare professionals towards the patient package inserts - a study in Palestine

    Directory of Open Access Journals (Sweden)

    Al-Ramahi R

    2012-03-01

    Full Text Available Reading the patient package inserts (PPIs is a key source of information about medications for patients. They should be clear and understandable to the general population. Objectives: The aims of this study were to obtain base-line data on the extent of reading PPIs by consumers and possible factors that might affect this; to explore the attitude of the Palestinian public and healthcare professionals towards the patient package inserts (PPIs; and to review a random sample of PPIs for the availability of different information.Methods: The first part of the study was a cross-sectional self-administered questionnaire. The questionnaire for consumers included 15 items. The questionnaire for healthcare professionals included 10 items and it was very similar to that of consumers with some modifications. In the second part, a random sample of PPIs was reviewed. In our community pharmacies, where medications are arranged according to their producing company, a researcher was asked to choose randomly 10-15 medications for every company to check for the availability of pharmacological, pharmaceutical and clinical information. Results: A total of 304 healthcare professionals out of 320 (95.0% and 223 consumers out of 240 (92.9% accepted to answer the survey. Forty five percent consumers reported that they always read the PPIs, and 29.3% said that they read the PPIs most of the times. Increased rate of reading the leaflet was found among females (P = 0.047. The preferred language for the PPIs was Arabic for most of the consumers (89.6% while it was English for most of the healthcare professionals (80.8%. 35.9% of the consumers and 43.6% of the healthcare professionals found the font size suitable. 42.3% of the consumers and 25.5% of the healthcare professionals said that they found the information in the PPIs useful and enough. The PPIs of 135 randomly sampled medications were reviewed. Many important sections were not found in the PPIs' sample. Conclusion

  16. Polychlorinated biphenyls (PCBs) in indoor air originating from sealants in contaminated and uncontaminated apartments within the same housing estate

    DEFF Research Database (Denmark)

    Frederiksen, Marie; Meyer, Harald William; Ebbehøj, Niels Erik

    2012-01-01

    . The PCB(tot) levels in the air of the contaminated section were 168-3843 ng m(-3) (mean: 1030 ng m(-3)), while the mean levels in the reference apartments were 6.03 ng m(-3). The sum of the 24 measured PCB congeners in sealants from the contaminated section was 187-221680 mg kg(-1). Principal component......Twenty-four congeners of polychlorinated biphenyls (PCBs) were measured in 83 air samples and 20 elastic sealants samples of apartments with PCB-containing sealants. In addition, PCBs were measured in 21 air samples from reference apartments located in an uncontaminated section of the same estate...... analysis revealed four groups among the sealant samples with different congener compositions, only two of which were clearly similar to known PCB mixtures, while two were not. Significant correlations and intercorrelations were observed between the lower chlorinated congeners in air and sealant, e...

  17. Fibrin sealant for mesh fixation in laparoscopic groin hernia repair does not increase long-term recurrence

    DEFF Research Database (Denmark)

    Fenger, Andreas Qwist; Helvind, Neel Maria; Pommergaard, Hans-Christian

    2016-01-01

    BACKGROUND: Methods of groin hernia repair include laparoscopic techniques using tissue-penetrating mesh fixation or non-penetrating fixation. Concerns regarding hernia repair include postoperative chronic pain, sexual dysfunction, and recurrence. Earlier estimations of recurrence rates have......) laparoscopic groin hernia repair using either fibrin sealant or tacks for mesh fixation. METHODS: This study used data from the Danish Hernia Database to create the following cohort: All patients operated laparoscopically for primary groin hernia with a TAPP procedure using fibrin sealant for mesh fixation...... difference in long-term reoperation rates and clinical recurrences in patients undergoing TAPP repair with meshes fixated with fibrin sealant compared with tacks....

  18. Migration of PCBs from Sealants to Adjacent Material

    DEFF Research Database (Denmark)

    Andersen, Helle Vibeke; Gunnarsen, Lars Bo; Kampmann, Kristoffer

    2015-01-01

    PCB in sealants can migrate into porous surfaces like concrete and brick and contaminate these materials. The study focuses on an analysis of concentration profiles in relation to alleviation of PCB contamination. The PCB content was determined in 20 samples of concrete and 6 samples of brick adj...

  19. Clinical Evaluation of applying a hydrophobic and a hydrophilic bonding agent on the retention and durability of fissure sealant therapy

    Directory of Open Access Journals (Sweden)

    Mostafa GHandi

    2016-03-01

    Full Text Available Background and Aims: As in fissure sealant therapy the tooth surface is mostly enamel, the use of an enamel bonding agent (hydrophobic bonding agent may be more cost effective than that of newer generations of bonding (hydrophilic bonding agents. The aim of this study was to compare the retention and durability of fissure sealant therapy when applying an enamel bonding agent, a dentin bonding agent and no bonding agent during 4 years. Materials and Methods: This study was done on the first permanent molars of the upper and lower jaws of 24 students of the first grade of a primary school (6-7 years old. On 36 teeth, a dentin bonding agent (Excite was applied under the fissure sealant and on 36 teeth an enamel bonding agent (Margin bond was applied under the fissure sealant. Then, 24 teeth were selected from these two groups and were compared with a group (including 24 teeth with no bonding agent under the fissure sealant (as control group. All the fissures of the teeth were evaluated annually for 4 years to find out the presence or absence of fissure sealant substance. Data were analyzed using Wilcoxon test. Results: From the statistical analysis, there was no significant difference in retention and durability of the fissure sealant substance comparing the group with dentin bonding agent (Excite and the group with enamel bonding agent (Margin bond. Also, using a bonding agent made no significant difference (P>0.05. Conclusion: According to the results of this study, using a bonding agent made no improvement in the retention and durability of fissure sealant substance.

  20. Evaluation of a hydrophilic gingival dental sealant in beagle dogs.

    Science.gov (United States)

    Sitzman, Clarence

    2013-01-01

    A liquid solution, gingival sealant containing polymers that form a barrier film upon application was evaluated in dogs. It is a non-toxic, low viscosity, hydrophilic barrier sealant that dries in approximately 10 to 15-seconds after subgingival application. It was designed as a preventative to be applied immediately following a professional oral hygiene procedure in order to block plaque and calculus formation in the sulcus and aid in the prevention of periodontal disease in companion animals. Additionally, the polymer was designed to promote an aerobic environment in the sulcus by oxygen and water transport through engineered pores within the polymer. A 30-day split-mouth, blinded study in two groups of 15 beagle dogs was used. Plaque was significantly (p periodontal disease in dogs.

  1. Transcutaneous Drainage of Gel-Like Substance after Application of Hydrogel Dural Sealant: Report of Two Cases.

    Science.gov (United States)

    Siman, Homayoun; Techy, Fernando

    2016-02-01

    Study Design Case report. Objective Incidental durotomy (IDT) is a common complication of spinal surgery. The use of collagen matrix graft along with hydrogel dural sealant is a common method of IDT repair. With this method, there have been several reported cases of detrimental dural sealant expansion in the literature. One case study reported an expansion rate greater than 300%; many report neurologic damage. This article reports the clinical course of two patients who developed postoperative transcutaneous drainage of a gel-like substance after the use of a dural sealant, which is a previously unreported complication. Methods The clinical course and treatment outcome of two patients is presented. Results Both patients experienced postoperative transcutaneous drainage of a gel-like substance at the surgical site. Case one began draining this substance on postoperative day 14. This patient required no further intervention, and the drainage ended after 3 mL of a gel-like substance was expressed from his incision while in the clinic. Case two began draining the gel on postoperative day 16. This patient underwent two washout procedures and resolution of the drainage. No infection was ever detected. Conclusions To our knowledge, our patients are the first reported cases of transcutaneous drainage of expanded dural sealant. It is important to take into consideration the unexpected expansion of a dural sealant when using it for the repair of IDT.

  2. Sealing effectiveness of fissure sealant bonded with universal adhesive systems on saliva-contaminated and noncontaminated enamel.

    Science.gov (United States)

    Memarpour, Mahtab; Shafiei, Fereshteh; Zarean, Mehran; Razmjoei, Faranak

    2018-01-01

    The effectiveness of sealants is dependent upon their adhesion to enamel surface. The aim of the study was to evaluate the sealing ability of a pit and fissure sealant used with a universal adhesive (etch-and-rinse vs. self-etch modes) when the site is contaminated with saliva. Adhesive properties were evaluated as microleakage and scanning electron microscopic (SEM) characteristics. A total of 72 mandibular third molars were randomly divided into 6 groups (n=12). Occlusal pits and fissures were sealed with an unfilled resin fissure sealant (FS) material with or without saliva contamination. The groups included: 1) phosphoric acid etching + FS (control), 2) phosphoric acid etching + Scotchbond Universal (etch-and-rinse) + FS, 3) phosphoric acid etching + saliva + Scotchbond Universal (etch-and-rinse) + FS, 4) Scotchbond Universal (self-etching) + FS,5) Scotchbond Universal (self-etching) + saliva + FS, and 6) Scotchbond Universal (self-etching) + saliva + Scotchbond Universal + FS. After thermocycling, the teeth were placed in 0.5% fuchsin, sectioned, and evaluated by digital microscopy. Two samples from each group were also observed by SEM. The data were analyzed with Kruskal-Wallis and Mann-Whitney tests for a significance of p universal adhesive in etch-and-rinse or self-etch modes was similar to that of conventional acid etching. Saliva contamination had a negative effect on sealant adhesion to pretreated enamel. Key words: Pit and fissure sealant, Universal adhesive, Saliva.

  3. Technical note: Computer-manufactured inserts for prosthetic sockets.

    Science.gov (United States)

    Sanders, Joan E; McLean, Jake B; Cagle, John C; Gardner, David W; Allyn, Katheryn J

    2016-08-01

    The objective of this research was to use computer-aided design software and a tabletop 3-D additive manufacturing system to design and fabricate custom plastic inserts for trans-tibial prosthesis users. Shape quality of inserts was tested right after they were inserted into participant's test sockets and again after four weeks of wear. Inserts remained properly positioned and intact throughout testing. Right after insertion the inserts caused the socket to be slightly under-sized, by a mean of 0.11mm, approximately 55% of the thickness of a nylon sheath. After four weeks of wear the under-sizing was less, averaging 0.03mm, approximately 15% of the thickness of a nylon sheath. Thus the inserts settled into the sockets over time. If existing prosthetic design software packages were enhanced to conduct insert design and to automatically generate fabrication files for manufacturing, then computer manufactured inserts may offer advantages over traditional methods in terms of speed of fabrication, ease of design, modification, and record keeping. Copyright © 2016 IPEM. Published by Elsevier Ltd. All rights reserved.

  4. Dental Sealants: Knowledge, Value, Opinion, and Practice among Dental Professionals of Bathinda City, India

    OpenAIRE

    Asawa, Kailash; Gupta, Vivek V.; Tak, Mridula; Nagarajappa, Ramesh; Chaturvedi, Pulkit; Bapat, Salil; Mishra, Prashant; Roy, Santanu Sen

    2014-01-01

    Objective. The purpose of the study was to assess the knowledge, value, opinion, and practice regarding use of dental sealants among private dental practitioners in Bathinda City, Punjab, India. Materials and Methods. A cross-sectional survey was conducted among all private dental practitioners in Bathinda City, Punjab. A self-administered structured questionnaire consisting of 28 items was used to assess their knowledge, value, opinion, and practice regarding dental sealants. One-way analysi...

  5. A prospective randomized trial comparing homologous and autologous fibrin sealants for the control of alveolar air leak.

    Science.gov (United States)

    Kılıç, Burcu; Erşen, Ezel; Demirkaya, Ahmet; Kara, H Volkan; Alizade, Nurlan; İşcan, Mehlika; Kaynak, Kamil; Turna, Akif

    2017-09-01

    Postoperative air leak is a common complication seen after pulmonary resection. It is a significant reason of morbidity and also leads to greater hospital cost owing to prolonged length of stay. The purpose of this study is to compare homologous sealant with autologous one to prevent air leak following pulmonary resection. A total of 57 patients aged between 20 and 79 (mean age: 54.36) who underwent pulmonary resection other than pneumonectomy (lobar or sublobar resections) were analyzed. There were 47 males (83%) and 10 females (17%). Patients who intraoperatively had air leaks were randomized to receive homologous (Tisseel; n=28) or autologous (Vivostat; n=29) fibrin sealant. Differences among groups in terms of air leak, prolonged air leak, hospital stay, amount of air leak were analyzed. Indications for surgery were primary lung cancer in 42 patients (71.9%), secondary malignancy in 5 patients (8.8%), and benign disease in 10 patients (17.5%). Lobectomy was performed in 40 patients (70.2%), whereas 17 patients (29.8%) had wedge resection. Thirteen (46.4%) patients developed complications in patients receiving homologous sealant while 11 (38.0%) patients had complication in autologous sealant group (P=0.711). Median duration of air leak was 3 days in two groups. Time to intercostal drain removal was 3.39 and 3.38 days in homologous and autologous sealant group respectively (P=0.978). Mean hospital stay was 5.5 days in patients receiving homologous sealant whereas it was 5.0 days in patients who had autologous agent (P=0.140). There were no significant differences between groups in terms of measured maximum air leak (P=0.823) and mean air leak (P=0.186). There was no significant difference in the incidence of complications between two groups (P=0.711). Autologous and heterologous fibrin sealants are safe and acts similarly in terms of air leak and hospital stay in patients who had resectional surgery.

  6. Evaluating cyclic fatigue of sealants during outdoor testing

    Science.gov (United States)

    R. Sam Williams; Steven Lacher; Corey Halpin; Christopher White

    2009-01-01

    A computer-controlled test apparatus (CCTA) and other instrumentation for subjecting sealant specimens to cyclic fatigue during outdoor exposure was developed. The CCTA enables us to use weather-induced conditions to cyclic fatigue specimens and to conduct controlled tests in-situ during the outdoor exposure. Thermally induced dimensional changes of an aluminum bar...

  7. Subclinical and clinical mastitis in heifers following the use of a teat sealant precalving.

    Science.gov (United States)

    Parker, K I; Compton, C; Anniss, F M; Weir, A; Heuer, C; McDougall, S

    2007-01-01

    This study investigated the effect in heifers of infusion of a bismuth subnitrate teat-canal sealant and bacterial intramammary infection (IMI) precalving on prevalence of postcalving IMI and incidence of clinical mastitis in the first 2 wk postcalving. Glands (n = 1,020) from heifers (n = 255) in 5 seasonally calving, pasture-fed dairy herds were randomly assigned within heifer to 1 of 4 treatment groups (no treatment; mammary gland secretion collection; infusion of a teat sealant; or sample collection with infusion of teat sealant). Heifers within a herd were enrolled on one calendar day, 31 d on average before the planned start of the seasonal calving period. Duplicate milk samples were collected from each gland within 4 d after calving for bacterial culture. Herd owners collected duplicate milk samples, before treatment, for bacterial culture from glands they defined as having clinical mastitis. The gland prevalence of IMI precalving was 15.5% and did not differ between herds. Bacteria isolated precalving included coagulase-negative staphylococci (76.9% of all bacteriologically positive samples), Streptococcus uberis (14.1%), Staphylococcus aureus (5.1%), Corynebacterium spp. (3.8%), and others (0.1%). The presence of an IMI precalving increased the risk of an IMI postcalving 3.6-fold and the risk of clinical mastitis 4-fold, relative to no IMI precalving. Infusion of the teat sealant reduced the risk of postcalving IMI due to Strep. uberis by 84%, and of clinical mastitis by 68%. Sampling the glands precalving had no effect on postcalving IMI or on clinical mastitis incidence. Use of an internal teat canal sealant in heifers precalving may be a useful tool for reducing the risk of subclinical and clinical mastitis in heifers.

  8. In Vitro Comparison of Microleakage of Two Materials Used as Pit and Fissure Sealants

    Directory of Open Access Journals (Sweden)

    Zahra Bahrololoomi

    2011-09-01

    Full Text Available Background and aims. Marginal seal of the material is extremely important in fissure sealant therapy. The aim of this study was to investigate microleakage of flowable composite resins and conventional fissure sealants with or without dentin bonding agent. Materials and methods. The occlusal surface of 60 intact extracted human premolars, divided into four groups, were cleaned with pumice/slurry, etched with 37% phosphoric acid for 15 seconds, rinsed and dried. Groups were treated differently: Excite bonding agent followed by Helioseal F fissure sealant in group1; Helioseal F alone in group 2; Excite bonding agent followed by Tetric Flow in group 3; and Tetric Flow alone in group 4. Light-curing was done after each application. After thermocycling, the whole surface of each specimen was coated with nail varnish except for one millimeter around the fissure sealant. The teeth were immersed in 2% basic fuchsin for 24 hours and then sectioned buccolingually. The sections were analyzed for leakage under a stereomicroscope. Data was analyzed by Kruskal-Wallis and Mann-Whitney tests at a significance level of P 0.05, except for groups 2 and 4 (P = 0.002 and groups 3 and 4 (P = 0.033. Conclusion. Use of a flowable composite with bonding agent is a good alternative for sealing pits and fissures; however, further in vitro and in vivo studies are necessary.

  9. Caries-preventive effect of a one-time application of composite resin and glass ionomer sealants after 5 years.

    NARCIS (Netherlands)

    Beiruti, N.; Frencken, J.E.F.M.; Hof, M.A. van 't; Taifour, D.; Palenstein Helderman, W.H. van

    2006-01-01

    The aim of the present trial was to (1) compare the caries-preventive effect of glass ionomer sealants, placed according to the atraumatic restorative treatment (ART) procedure, with composite resin sealants over time and (2) investigate the caries-preventive effect after complete disappearance of

  10. Effect of enamel sealants on tooth bleaching and on the color stability of the result.

    Science.gov (United States)

    Corcodel, N; Hassel, A J; Sen, S; Saure, D; Rammelsberg, P; Lux, C J; Zingler, S

    2017-04-01

    The purpose of this in vitro study was to evaluate the effect of enamel sealants on bleaching of natural teeth by use of 40 % hydrogen peroxide in a dental surgery. The color stability of the results from bleaching was, furthermore, determined 10 months after the bleaching procedure. In a standardized setting, four sealants (Pro Seal ® , Light Bond™ Sealant, Protecto ® , and Clinpro™ XT Varnish) were applied to and removed from human teeth in accordance with the manufacturer's instructions. Natural teeth served as medium; half of the teeth were sealed and the others served as controls. Hydrogen peroxide gel (40 %; Opalescence Boost; Ultradent Products, South Jordan, UT, USA) was used as bleaching agent. Color measurement was performed with a spectroradiometer (Photoresearch PR670) before the bleaching process (T1) and 24 h (T2) and 10 months (T3) after bleaching. The spectroradiometer results were expressed by use of the Commission Internationale de l'Éclairage (CIE) L*a*b* color notation. The L*, a*, and b* values of the sealed and the unsealed surfaces were not significantly different at any time during the study (p > 0.05), irrespective of the sealant used. Ten months after the bleaching process, mean L*, a*, and b* values were lower than at 1-day post-bleaching; the mean value of ΔE between 1-day post-bleaching and 10 months post-bleaching was 2.46 (±3.1). The results of the study suggest that the effectiveness of professional tooth whitening is not appreciably affected by the application of the four sealants tested.

  11. Long-Standing Motor and Sensory Recovery following Acute Fibrin Sealant Based Neonatal Sciatic Nerve Repair

    Directory of Open Access Journals (Sweden)

    Natalia Perussi Biscola

    2016-01-01

    Full Text Available Brachial plexus lesion results in loss of motor and sensory function, being more harmful in the neonate. Therefore, this study evaluated neuroprotection and regeneration after neonatal peripheral nerve coaptation with fibrin sealant. Thus, P2 neonatal Lewis rats were divided into three groups: AX: sciatic nerve axotomy (SNA without treatment; AX+FS: SNA followed by end-to-end coaptation with fibrin sealant derived from snake venom; AX+CFS: SNA followed by end-to-end coaptation with commercial fibrin sealant. Results were analyzed 4, 8, and 12 weeks after lesion. Astrogliosis, microglial reaction, and synapse preservation were evaluated by immunohistochemistry. Neuronal survival, axonal regeneration, and ultrastructural changes at ventral spinal cord were also investigated. Sensory-motor recovery was behaviorally studied. Coaptation preserved synaptic covering on lesioned motoneurons and led to neuronal survival. Reactive gliosis and microglial reaction decreased in the same groups (AX+FS, AX+CFS at 4 weeks. Regarding axonal regeneration, coaptation allowed recovery of greater number of myelinated fibers, with improved morphometric parameters. Preservation of inhibitory synaptic terminals was accompanied by significant improvement in the motor as well as in the nociceptive recovery. Overall, the present data suggest that acute repair of neonatal peripheral nerves with fibrin sealant results in neuroprotection and regeneration of motor and sensory axons.

  12. In vitro study of Streptococcus mutans adhesion on composite resin coated with three surface sealants

    Directory of Open Access Journals (Sweden)

    Da Hye Kim

    2017-02-01

    Full Text Available Objectives Although the coating of surface sealants to dental composite resin may potentially reduce bacterial adhesion, there seems to be little information regarding this issue. This preliminary in vitro study investigated the adhesion of Streptococcus mutans (S. mutans on the dental composite resins coated with three commercial surface sealants. Materials and Methods Composite resin (Filtek Z250 discs (8 mm in diameter, 1 mm in thickness were fabricated in a mold covered with a Mylar strip (control. In group PoGo, the surfaces were polished with PoGo. In groups PS, OG, and FP, the surfaces polished with PoGo were coated with the corresponding surface sealants (PermaSeal, PS; OptiGuard, OG; Fortify Plus, FP. The surfaces of the materials and S. mutans cells were characterized by various methods. S. mutans adhesion to the surfaces was quantitatively evaluated using flow cytometry (n = 9. Results Group OG achieved the lowest water contact angle among all groups tested (p 0.05 or significantly lower (group OG, p < 0.001 bacterial adhesion when compared with the control group. Conclusions The application of the surface sealants significantly reduced S. mutans adhesion to the composite resin polished with the PoGo.

  13. Effect of occlusal calculus utilized as a potential "biological sealant" in special needs patients with gastric feeding tubes: a qualitative in vitro contrast to pit and fissure sealant restorations.

    Science.gov (United States)

    Owens, Barry M; Sharp, Harry K; Fourmy, Emily E; Phebus, Jeffrey G

    2016-01-01

    The aim of this case report and in vitro investigation was to evaluate the marginal microleakage of intact occlusal calculus of primary molars extracted from a special needs patient who received nutrition via a gastric feeding tube. An adolescent with a history of developmental disturbance presented for routine dental care in a hospital facility. Prophylaxis was performed, and 2 mandibular permanent molars were restored. Five primary molars were extracted due to mobility and delayed retention. Heavy deposits of intact calculus were present on the occlusal surfaces of the primary teeth. The extracted teeth were immersed in methylene blue dye solution, invested in acrylic resin, sectioned into blocks, and photographed at 20× and 40× magnification. Previously photographed calculus-free molars with pit and fissure sealants were reviewed and served as contrasting "restorations." The occlusal calculus on the primary teeth extracted from the patient absorbed the dye, while the comparison teeth containing pit and fissure sealants exhibited varying degrees of marginal dye penetration (microleakage). No marginal microleakage was noted in the calculus specimens, indicating that this substrate may serve as a "natural" occlusal surface sealant and that its removal from occlusal surfaces during routine oral prophylaxis may be unnecessary.

  14. Effectiveness of Dry Cow Therapy Comprising Antibiotic Treatment, Internal Teat Sealant, and α-Tocopherol Against New Intramammary Infections in Cows

    Directory of Open Access Journals (Sweden)

    Cengiz Mehmet

    2015-04-01

    Full Text Available The aim of this study was to evaluate the preventive effectiveness of dry cow therapy based on antibiotic, internal teat sealant, and α-tocopherol administered separately or in various combinations at drying-off The study was performed on 322 uninfected quarters of 95 cows originating from three dairy herds. The new intramammary infection rates after calving were measured to evaluate the effectiveness. The quarters were divided into six groups differing in treatment, namely: control group (group C, n = 40 and five treatment groups. Treatment groups were arranged as follows: group A (antibiotic alone, n = 81, group AS (antibiotic + sealant, n = 40, group AST (antibiotic + sealant + α-tocopherol, n = 40, group T (α-tocopherol alone, n = 40, group S (sealant alone, n = 81. New infection rate amounted to 47.5% in group C. The treatment in group AST significantly prevented from the occurrence of new intramammary infections (12.5%, P 0.05, although the use of the sealant alone (group S decreased the risk of new infection (24.7%, P 0.05. Increased α-tocopherol level (P < 0.05 was detected after calving in the quarters from cows that received α-tocopherol injections. In conclusion, the combination of antibiotic, internal teat sealant, and α-tocopherol used in dry cow therapy showed a significantly better preventive effect against new intramammary infections, than the therapeutics administered separately.

  15. Fissure sealant materials: Wear resistance of flowable composite resins.

    Science.gov (United States)

    Asefi, Sohrab; Eskandarion, Solmaz; Hamidiaval, Shadi

    2016-01-01

    Background. Wear resistance of pit and fissure sealant materials can influence their retention. Wear characteristics of sealant materials may determine scheduling of check-up visits. The aim of this study was to compare wear resistance of two flowable composite resins with that of posterior composite resin materials. Methods. Thirty-five disk-shaped specimens were prepared in 5 groups, including two flowable composite resins (Estelite Flow Quick and Estelite Flow Quick High Flow), Filtek P90 and Filtek P60 and Tetric N-Ceram. The disk-shaped samples were prepared in 25-mm diameter by packing them into a two-piece aluminum mold and then light-cured. All the specimens were polished for 1minute using 600-grit sand paper. The samples were stored in distilled water at room temperature for 1 week and then worn by two-body abrasion test using "pin-on-disk" method (with distilled water under a 15-Nload at 0.05 m/s, for a distance of 100 meter with Steatite ceramic balls antagonists). A Profilometer was used for evaluating the surface wear. Data were analyzed with the one-way ANOVA. Results. Estelite Flow Quick exhibited 2708.9 ± 578.1 μm(2) and Estelite Flow Quick High Flow exhibited 3206 ± 2445.1 μm(2)of wear but there were no significant differences between the groups. They demonstrated similar wear properties. Conclusion. Estelite flowable composite resins have wear resistance similar to nano- and micro-filled and micro-hybrid composite resins. Therefore, they can be recommended as pit and fissure sealant materials in the posterior region with appropriate mechanical characteristics.

  16. 48 CFR 1852.211-70 - Packaging, handling, and transportation.

    Science.gov (United States)

    2010-10-01

    ... transportation. 1852.211-70 Section 1852.211-70 Federal Acquisition Regulations System NATIONAL AERONAUTICS AND... and Clauses 1852.211-70 Packaging, handling, and transportation. As prescribed in 1811.404-70, insert the following clause: Packaging, Handling, and Transportation (SEPT 2005) (a) The Contractor shall...

  17. Engaging Stakeholders in Patient-Centered Outcomes Research Regarding School-Based Sealant Programs.

    Science.gov (United States)

    Chi, Donald L; Milgrom, Peter; Gillette, Jane

    2018-02-01

    Purpose: The purpose of this study was to use qualitative methods to describe the key lessons learned during the stakeholder engagement stage of planning a randomized clinical trial comparing outcomes of silver diamine fluoride (SDF) as an alternative to pit-and-fissure sealants in a school-based delivery system. Methods: Eighteen caregivers and community-based stakeholders with involvement in the school-based sealant program Sealants for Smiles from the state of Montana, were recruited for this qualitative study. United States (U.S.) Patient-Centered Outcomes Research Institute (PCORI) methodology standards were used to develop two semi-structured interview guides consisting of 6 questions. One interview guide was used for telephone interviews with caregivers and the second was used for a stakeholder focus group. Content analytic methods were used to analyze the data. Results: All participants believed that a study comparing SDF and sealants was clinically relevant. Non-caregiver stakeholders agreed with the proposed primary outcome of the study (caries prevention) whereas caregivers also emphasized the importance of child-centered outcomes such as minimizing dental anxiety associated with dental care. Stakeholders described potential concerns associated with SDF such as staining and perceptions of safety and discussed ways to address these concerns through community engagement, appropriate framing of the study, proper consent procedures, and ongoing safety monitoring during the trial. Finally, stakeholders suggested dissemination strategies such as direct communication of findings through professional organizations and encouraging insurance plans to incentivize SDF use by reimbursing dental providers. Conclusions: Involving key stakeholders in early planning is essential in developing patient-centered research questions, outcomes measures, study protocols, and dissemination plans for oral health research involving a school-based delivery system. Copyright © 2018

  18. Efficacy of fibrin-sealants in reducing biliary leakage following laparoscopic common bile duct exploration.

    Science.gov (United States)

    Parra-Membrives, Pablo; Martínez-Baena, Darío; Lorente-Herce, José Manuel; Martín-Balbuena, Ramón

    2018-05-21

    In spite of the acquired experience with laparoscopic common bile duct exploration (LCBDE) for choledocholithiasis management, there is still a risk of biliary leakage of 5% to 15% following choledochotomy closure. We evaluate the usefulness of fibrin-collagen sealants to reduce the incidence of biliary fistula after laparoscopic choledochorrhaphy. We report a retrospective analysis of 96 patients undergoing LCBDE from March 2009 to March 2017, whose closure of the bile duct was completed by antegrade stenting and choledochorraphy or by performing a primary suture. The study population was divided into two groups according to whether they received a collagen-fibrin sealant covering the choledochorrhaphy or not, analyzing the incidence of postoperative biliary fistula in each group. Thirty-nine patients (41%) received a fibrin-collagen sponge while the bile duct closure was not covered in the remaining 57 patients (59%). The incidence of biliary fistula was 7.7% (3 patients) in the first group and 14% (8 patients) in the second group (P=.338). In patients who underwent primary choledochorraphy, the fibrin-collagen sealant reduced the incidence of biliary leakage significantly (4.5% vs. 33%, P=.020), which was a protective factor with an odds ratio of 10.5. Fibrin-collagen sealants may decrease the incidence of biliary fistula in patients who have undergone primary bile duct closure following LCBDE. Copyright © 2018 AEC. Publicado por Elsevier España, S.L.U. All rights reserved.

  19. Effect of sealant agents on the color stability and surface roughness of nanohybrid composite resins.

    Science.gov (United States)

    Dede, Doğu Ömür; Şahin, Onur; Koroglu, Aysegül; Yilmaz, Burak

    2016-07-01

    The effect of sealant agents on the surface roughness and color stability of nanohybrid composite resins is unknown. The purpose of this in vitro study was to evaluate the effect of sealant agents on the surface roughness and color stability of 4 nanohybrid composite resin materials. Forty disks (10×2 mm) were fabricated for each nanohybrid composite resin material (Z-550, Tetric EvoCeram, Clearfill Majesty, Ice) (N=160) and divided into 4 surface treatment groups: 1 conventional polishing (control) and 3 different sealant agent (Palaseal, Optiglaze, BisCover) coupling groups (n=10). The specimens were thermocycled, and surface roughness (Ra) values were obtained with a profilometer. Scanning electron microscope images were also recorded. CIELab color parameters of each specimen were measured with a spectrophotometer before and after 7 days of storage in a coffee solution. Color differences were calculated by the CIEDE 2000 (ΔE00) formula. The data were statistically analyzed by 2-way ANOVA and by the Tukey HSD test (α=.05). The surface treatment technique significantly affected the Ra values of the composite resins tested (Pcomposite resin material was also significant for ΔE00 values (Pcomposite resin groups, significant decreases in Ra were observed only for the Palaseal agent coupled composite resin groups (except Ice) compared with the control groups (Pcomposite resin group, except for BisCover applied Clearfill Majesty (Pcomposite resin groups, significant differences were observed between the color change seen with BisCover and other sealants for Clearfill Majesty composite resin (Pcomposite resins except for Ice produced smoother surfaces. All surface sealant agents provided less discoloration of nanohybrid composite resins after coffee staining compared with conventional polishing except for BisCover applied Clearfill Majesty composite resin. Copyright © 2016 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All

  20. Efficacy of a Self-expanding Tract Sealant Device in the Reduction of Pneumothorax and Chest Tube Placement Rates After Percutaneous Lung Biopsy: A Matched Controlled Study Using Propensity Score Analysis.

    Science.gov (United States)

    Ahrar, Judy U; Gupta, Sanjay; Ensor, Joe E; Mahvash, Armeen; Sabir, Sharjeel H; Steele, Joseph R; McRae, Stephen E; Avritscher, Rony; Huang, Steven Y; Odisio, Bruno C; Murthy, Ravi; Ahrar, Kamran; Wallace, Michael J; Tam, Alda L

    2017-02-01

    To evaluate the use of a self-expanding tract sealant device (BioSentry™) on the rates of pneumothorax and chest tube insertion after percutaneous lung biopsy. In this retrospective study, we compared 318 patients who received BioSentry™ during percutaneous lung biopsy (treated group) with 1956 patients who did not (control group). Patient-, lesion-, and procedure-specific variables, and pneumothorax and chest tube insertion rates were recorded. To adjust for potential selection bias, patients in the treated group were matched 1:1 to patients in the control group using propensity score matching based on the above-mentioned variables. Patients were considered a match if the absolute difference in their propensity scores was ≤equal to 0.02. Before matching, the pneumothorax and chest tube rates were 24.5 and 13.1% in the control group, and 21.1 and 8.5% in the treated group, respectively. Using propensity scores, a match was found for 317 patients in the treatment group. Chi-square contingency matched pair analysis showed the treated group had significantly lower pneumothorax (20.8 vs. 32.8%; p = 0.001) and chest tube (8.2 vs. 20.8%; p 30 cases of both treatment and control cases demonstrated similar findings: the treated group had significantly lower pneumothorax (17.6 vs. 30.2%; p = 0.002) and chest tube (7.2 vs. 18%; p = 0.001) rates. The self-expanding tract sealant device significantly reduced the pneumothorax rate, and more importantly, the chest tube placement rate after percutaneous lung biopsy.

  1. Clinical Evaluation of an Adhesive Sealant for Controlling Dental Caries in Naval Personnel: One-Year Results

    Science.gov (United States)

    1974-08-20

    safeguards were employed in that a voltage monitoring strip chart recorder was employed during sealant placement to ensure continuous delivery of...adequate voltage to the ultraviolet light source (Nuva- Lite)* used for sealant polymerization. Also, a new air compressor** with suitable...ment effect in young Naval personnel. 2. The very low occlusal attack rate for untreated control teeth 3. Dirks, O. B., Houwink, B. and Kwant , G. W

  2. Frequency of remnants of sealants left behind in pits and fissures of occlusal surfaces after 2 and 3 years.

    NARCIS (Netherlands)

    Hu, X.; Zhang, W.; Fan, M.; Mulder, J.; Frencken, J.E.F.M.

    2017-01-01

    OBJECTIVES: The null-hypothesis tested was that there was no difference in the frequency of remnants of high-viscosity glass-ionomer sealants left behind in pits and fissures of occlusal surfaces of first permanent molars and that of resin composite and glass-carbomer sealants. MATERIALS AND

  3. A clinical trial to evaluate the retention of a silver cermet-ionomer cement used as a fissure sealant.

    Science.gov (United States)

    Mills, R W; Ball, I A

    1993-01-01

    A randomized clinical trial was under-taken to compare the retention of a silver cermet-ionomer cement, Ketac Silver, with a conventional, autopolymerizing BIS-GMA resin sealant, Delton, using matched pairs of fissure sites within each subject's mouth. One hundred twenty matched contralateral pairs of fissure sites in first and second permanent molars of 53 school children were sealed with the two materials. The choice of site and material was selected at random. The ages of the children ranged from five to 16 years; first permanent molars were sealed in the five- to 10-year age group, and second permanent molars in the 11- to 16-year age group. Sealants were assessed as present, partly present, or absent at 6, 12, and 24 months. The number of pairs of sites available for reassessment declined from 102 at six months to 59 at 24 months as patients were lost to the study. Retention rates were higher for the Ketac Silver sealants at all three inspection intervals (P cermet cement was better retained than conventional resin sealants in younger children.

  4. Pit and fissure sealants versus fluoride varnishes for preventing dental decay in children and adolescents

    DEFF Research Database (Denmark)

    Hiiri, Anne; Ahovuo-Saloranta, Anneli; Nordblad, Anne

    2010-01-01

    the effectiveness of pit and fissure sealants to be statistically significantly higher than an application of fluoride varnish every 6 months in preventing occlusal decays of first molars at 23 months (with a RR of 0.74, 95% confidence interval (CI) 0.58 to 0.95); and at 4 years and 9 years (with a RR of 0.42, 95...... caries on the fluoride varnished tooth surfaces, compared to sealed plus fluoride varnished surfaces, with a RR of 0.36 (95% CI 0.21 to 0.61). AUTHORS' CONCLUSIONS: There was some evidence on the superiority of pit and fissure sealants over fluoride varnish application in the prevention of occlusal......BACKGROUND: The majority of the detected increment in dental caries among children and adolescents is confined to pit and fissure surfaces of first molars. OBJECTIVES: The objective of this study was to compare the effectiveness of pit and fissure sealants with fluoride varnishes in the prevention...

  5. Chylothorax after mediastinal ganglioneuroma resection treated with fibrin sealant patch: a case report

    Science.gov (United States)

    Chiarelli, Marco; Achilli, Pietro; Guttadauro, Angelo; Vertemati, Giuseppe; Terragni, Sabina; De Simone, Matilde

    2017-01-01

    Chylothorax is a severe condition resulting from the accumulation of chyle into the pleural space. We report the treatment of postoperative chylothorax after resection of mediastinal ganglioneuroma in a 17-year-old boy. Since conservative measures were not effective, we performed direct ligation of lymphatic vessels and pleurodesis. At subsequent surgical re-exploration for persisting chylothorax, accurate inspection of pleural cavity revealed residual chyle leakage. Fibrin sealant patches (TachoSil®) were placed over the source of leak with complete resolution of chylous effusion. To our knowledge, this is the first report of postoperative chylothorax successfully treated by the use of a fibrin sealant patch. PMID:29221335

  6. The effect of surface sealants with different filler content on microleakage of Class V resin composite restorations.

    Science.gov (United States)

    Hepdeniz, Ozge Kam; Temel, Ugur Burak; Ugurlu, Muhittin; Koskan, Ozgur

    2016-01-01

    Microleakage is still one of the most cited reasons for failure of resin composite restorations. Alternative methods to prevent microleakage have been investigated increasingly. The aim of this study is to evaluate the microleakage in Class V resin composite restorations with or without application of surface sealants with different filler content. Ninety-six cavities were prepared on the buccal and lingual surfaces with the coronal margins located in enamel and the cervical margins located in dentin. The cavities restored with an adhesive system (Clearfil SE Bond, Kuraray, Tokyo, Japan) and resin composite (Clearfil Majesty ES-2, Kuraray, Tokyo, Japan). Teeth were stored in distilled water for 24 h and separated into four groups according to the surface sealants (Control, Fortify, Fortify Plus, and G-Coat Plus). The teeth were thermocycled (500 cycles, 5-55° C), immersed in basic fuchsine, sectioned, and analyzed for dye penetration using stereomicroscope. The data were submitted to statistical analysis by Kruskal-Wallis and Bonferroni-Dunn test. The results of the study indicated that there was minimum leakage at the enamel margins of all groups. Bonferroni-Dunn tests revealed that Fortify and GC-Coat groups showed significantly less leakage than the Control group and the Fortify Plus group at dentin margins in lingual surfaces (P < 0.05). The all surface sealants used in this study eliminated microleakage at enamel margins. Moreover, unfilled or nanofilled surface sealants were the most effective in decreasing the degree of marginal microleakage at dentin margins. However, viscosity and penetrability of the sealants could be considered for sealing ability besides composition.

  7. 21 CFR 310.501 - Patient package inserts for oral contraceptives.

    Science.gov (United States)

    2010-04-01

    ... dispenser may provide the insert to the parent or legal guardian of a legally incompetent patient (or to the... the effectiveness of oral contraceptives in preventing pregnancy, the contraindications to the drug's... concerning the increased risks associated with cigarette smoking and oral contraceptive use. (5) A discussion...

  8. Prevalence of sealants in relation to dental caries on the permanent molars of 12 and 15-year-old Greek adolescents. A national pathfinder survey

    Directory of Open Access Journals (Sweden)

    Mamai-Homata Eleni

    2011-02-01

    Full Text Available Abstract Background The use of sealants as an effective measure for the prevention of pit and fissure caries in children has been well documented by several studies; either they are used on an individual or on a public health basis. In order to plan and establish a national preventive program with sealants in a community, it is mandatory to know the epidemiological pattern of caries along with other variables influencing their use and effectiveness. Aims: To assess the utilization and distribution pattern of pit and fissure sealants on the first and second permanent molars of Greek adolescents and to evaluate whether the existing usage of sealants and some socio-demographic factors are correlated to caries prevalence on the population examined Methods A stratified cluster sample of 2481 Greek adolescents was selected according to WHO guidelines (1224 twelve and 1,257 fifteen-year-old, living in urban and rural areas in 11 districts within the country. Five calibrated examiners carried out clinical examinations, recording caries experience at the dentine threshold (BASCD criteria and presence or absence of sealants along with Socio-demographic indicators associated with oral health. Mann Whitney and Pearson's chi-square non parametric tests were utilized for assessing the data. The level of significance was p Results Sealants utilization varied considerably within the different districts, with 8,3% of the 12 and 8,0% of the 15-year-old adolescents having at least one sealed molar. Sealants reduced DMFS scores by 11% in the 12-year-olds and by 24% in the 15-year-olds, while 15-year-old adolescents from rural areas had a statistically significant (p = 0.002 less chance of having sealants (71% compared to children from urban areas. Girls had higher chance to receive sealants in both age groups (26% for the 12 and 19% for the 15-year-old as well as patients that visited the dentist for prevention compared to those visiting the dentist because they

  9. The differences of saliva pH before and after application of Bis-GMA resin based-pit and fissure sealant

    Directory of Open Access Journals (Sweden)

    Ayub Irmadani Anwar

    2016-06-01

    Full Text Available Pit and fissure sealant applications is one way to prevent caries. One of the effective ingredient as a pit and fissure sealant is a Bis-GMA resin. One of the active components  of  Bis-GMA  resin  is  sodium  fluoride,  which is capable  of releasing fluoride ions to the tooth surface and able to improve the repair and remineralization process through the replacement  of  calcium and phosphate ions found in saliva to increase the pH of saliva. This study was to determine the effect of pit and fissure sealant applications made from Bis-GMA resin to pH of saliva in children aged 6-12 years. The study design is pre and post test with control group design. Saliva samples were derived from 15 pediatric patients has met the criteria. The pH of saliva were taken before and after the application of pit and fissure sealant made from Bis-GMA and measured with pH meter. This study used a non-parametric test, the Wilcoxon Signed Rank test. The results of this study are also supported by the results of statistical tests showed p-: 0.005 (p<0.05 value, which means that there are significant differences in pH of saliva before and after the application of pit and fissure sealant made from Bis-GMA resin.

  10. Transcutaneous Drainage of Gel-Like Substance after Application of Hydrogel Dural Sealant: Report of Two Cases

    OpenAIRE

    Siman, Homayoun; Techy, Fernando

    2015-01-01

    Study Design?Case report. Objective?Incidental durotomy (IDT) is a common complication of spinal surgery. The use of collagen matrix graft along with hydrogel dural sealant is a common method of IDT repair. With this method, there have been several reported cases of detrimental dural sealant expansion in the literature. One case study reported an expansion rate greater than 300%; many report neurologic damage. This article reports the clinical course of two patients who developed postoperativ...

  11. Use of a sealant to prevent prolonged air leaks after lung resection: a prospective randomized study.

    Science.gov (United States)

    Lequaglie, Cosimo; Giudice, Gabriella; Marasco, Rita; Morte, Aniello Della; Gallo, Massimiliano

    2012-10-08

    Pulmonary air leaks are common complications of lung resection and result in prolonged hospital stays and increased costs. The purpose of this study was to investigate whether, compared with standard care, the use of a synthetic polyethylene glycol matrix (CoSeal®) could reduce air leaks detected by means of a digital chest drain system (DigiVent™), in patients undergoing lung resection (sutures and/or staples alone). Patients who intraoperatively showed moderate or severe air leaks (evaluated by water submersion tests) were intraoperatively randomized to receive just sutures/staples (control group) or sutures/staples plus CoSeal® (sealant group). Differences among the groups in terms of air leaks, prolonged air leaks, time to chest tube removal, length of hospital stay and related costs were assessed. In total, 216 lung resection patients completed the study. Nineteen patients (18.1%) in the control group and 12 (10.8%) patients in the sealant group experienced postoperative air leaks, while a prolonged air leak was recorded in 11.4% (n=12) of patients in the control group and 2.7% (n=3) of patients in the sealant group. The difference in the incidence of air leaks and prolonged air leaks between the two groups was statistically significant (p=0.0002 and p=0.0013). The mean length of hospital stay was significantly shorter in the sealant group (4 days) than the control group (8 days) (p=0.0001). We also observed lower costs in the sealant group than the control group. The use of CoSeal® may decrease the occurrence and severity of postoperative air leaks after lung resection and is associated with shorter hospital stay. Not registered. The trial was approved by the Institutional Review Board of the IRCCS-CROB Basilicata Regional Cancer Institute, Rionero in Vulture, Italy.

  12. Effect of Acidulated Phosphate Fluoride (APF on the Mcroleakage of Composite Flow and Fssure Sealant Restorations

    Directory of Open Access Journals (Sweden)

    Arash Poorsattar Bejeh Mir

    2012-09-01

    Full Text Available Background and Aims: A large number of investigations have revealed that physical and chemical alterations and weight loss could occur in composite materials exposed to acidic phosphate fluoride (APF gel. The purpose of this study was to assess the microleakage of a fissure sealant and a flow composite exposed to acidulated phosphate fluoride (APF gel. Materials and Methods: In this in vitro study, 60 intact human extracted premolar teeth were used. After preparing the occlusal groove, the teeth were divided into two groups (n=30. Teeth were filled with either Helioseal fissure sealant (Vivadent, Germany or Tetric flow composite (Vivadent, Germany. After that, each group was divided into two subgroups (n=15: 1.23% APF gel (Sultan, U.S.A was applied in the case subgroups, while control subgroups were preserved in normal saline solution. All of teeth were covered with 2 layers of nail varnish except for the filling zone and 1mm around the border of filling. After submerging in 0.5% fushin solution, specimens were sectioned bucco-lingually. Then dye penetration through the filling and fissure sealant was assessed by means of a stereo-microscope. The depth of dye penetration was scored. The data were analyzed using One-way ANOVA and Levene test. Results: The mean values of dye penetration were 1.26±1.09, 1.4±1.05, 1.2±1.37, and 1.4±1.35 for fissure sealant+gel, composite+gel, composite+normal saline, and normal saline groups, respectively. No significant difference was found in inter-groups (P=0.96. Conclusion: Considering the result of the present research, APF gel had no significant effect on the microleakage of Tetric flow composite filling and Helioseal fissure sealant and thus, it can be applied for routine usage.

  13. Radon penetration of concrete slab cracks, joints, pipe penetrations, and sealants

    NARCIS (Netherlands)

    Nielson, KK; Rogers, VC; Holt, RB; Pugh, TD; Grondzik, WA; deMeijer, RJ

    1997-01-01

    Radon movement through 12 test slabs with different cracks, pipe penetrations, cold joints, masonry blocks, sealants, and tensile stresses characterized the importance of these anomalous structural domains, Diffusive and advective radon transport were measured with steady-state air pressure

  14. Comparison of Caries Prevention With Glass Ionomer and Composite Resin Fissure Sealants

    Directory of Open Access Journals (Sweden)

    Aylin Akbay Oba

    2009-11-01

    Conclusion: Under field conditions in which moisture control was not effective, a high-viscosity and less technique-sensitive glass ionomer material can be used as an effective sealant material, rather than resin.

  15. Usefulness of hemostatic sealants for minimizing ovarian damage during laparoscopic cystectomy for endometriosis.

    Science.gov (United States)

    Choi, Chahien; Kim, Woo Young; Lee, Dong Hee; Lee, San Hui

    2018-03-01

    We aimed to evaluate the impact of topical hemostatic sealants and bipolar coagulation during laparoscopic ovarian endometriotic cyst resection on ovarian reserve by comparing the rates of decrease in anti-Müllerian hormone (AMH). A randomized prospective data collection was made on women aged 19-45 years who planned to have laparoscopic ovarian cystectomy at one of two institutions (n = 80), Kangbuk Samsung Hospital, Seoul, Korea or National Health Insurance Service Ilsan Hospital, Goyang, Korea, from January 2014 to April 2016. Patients were randomly divided into two groups treated with either a topical hemostatic sealant or bipolar coagulation for hemostasis. The hemostatic group was randomized to the FloSeal or TachoSil subgroups. Preoperative and 3-month postoperative AMH levels were checked and the rates of decrease of AMH were compared. All patients enrolled were treated with dienogest (Visanne) for 6-12 months. None were lost to follow-up at postoperative 3 months, but about one-third of the patients had been lost to follow-up by 6-12 months. AMH was significantly decreased in both groups 3 months postoperatively; however, the rate of decrease in the bipolar coagulation group was greater than that in the hemostatic sealant group, 41.9% (interquartile range [IQR], 22.29-65.24) versus 18.1% (IQR, 10.94-29.90), P = 0.007. Between the two hemostatic subgroups, there was no significant difference in AMH decrease rate, 14.95% (IQR, 11.34-21.21) versus 18.1% (IQR 9.76-40.70), P = 0.204. Hemostatic sealants may be an alternative to bipolar coagulation for preservation of ovarian reserve after laparoscopic ovarian cystectomy for endometriosis. © 2017 Japan Society of Obstetrics and Gynecology.

  16. Using PATIMDB to create bacterial transposon insertion mutant libraries.

    Science.gov (United States)

    Urbach, Jonathan M; Wei, Tao; Liberati, Nicole; Grenfell-Lee, Daniel; Villanueva, Jacinto; Wu, Gang; Ausubel, Frederick M

    2009-04-01

    PATIMDB is a software package for facilitating the generation of transposon mutant insertion libraries. The software has two main functions: process tracking and automated sequence analysis. The process tracking function specifically includes recording the status and fates of multiwell plates and samples in various stages of library construction. Automated sequence analysis refers specifically to the pipeline of sequence analysis starting with ABI files from a sequencing facility and ending with insertion location identifications. The protocols in this unit describe installation and use of PATIMDB software.

  17. Prevalence of Dental Caries and Fissure Sealants in a Portuguese Sample of Adolescents

    Science.gov (United States)

    Veiga, Nélio J.; Pereira, Carlos M.; Ferreira, Paula C.; Correia, Ilidio J.

    2015-01-01

    Introduction The aims of this study were to assess the prevalence of dental caries and the DMFT index, as well as the distribution pattern of pit and fissure sealants on permanent teeth in a Portuguese sample of adolescents, and to assess whether the existing usage of sealants and socio-demographic factors are correlated to caries prevalence on the examined sample. Materials and Methods A cross-sectional study was designed with a sample of 447 adolescents aged 12 to 18 years old, attending a public school in Sátão, Portugal. A self-administered questionnaire with questions about oral health behaviours and socio-economic status was answered by adolescents in the classroom. Clinical examination of oral health status and assessment of fissure sealants were accomplished by only one trained member of the research team. Results We obtained a DMFT index of 3.32 (2.92), which indicates a moderate level of prevalence of dental caries. When considering a DMFT = 0, we found significant statistical differences between the parents´ level of education (≤ 4th grade = 26.3 vs 5th–12th grade = 18.8 vs Portuguese adolescents. The establishment of a more targeted preventive program with better and more effective oral health education is essential, having into account socio-demographic aspects. PMID:25803849

  18. Social Marketing Risk-Framing Approaches for Dental Sealants in Rural American Indian Children.

    Science.gov (United States)

    Larsson, Laura S; Champine, Dorothy; Hoyt, Dee; Lin, Lillian; Salois, Emily; Silvas, Sharon; Tail, Terri Weasel; Williams, Matthew

    2015-01-01

    To compare three variants of a culturally relevant and theoretically based message to determine the most influential risk-framing approach for improving intention to place dental sealants for preschool children. A convenience sample of adult, American Indian participants (n = 89) attending a community health fair were assigned to view a gain-framed, loss-framed, or mix-framed dental sealant message. We compared participants' scores on a 46-item survey to determine the relative effect of the frame assignment on seven indices of behavior change. The mean difference in participants' stage-of-change scores (x = 1.17, n = 89, SD = 1.90) demonstrated a significant improvement for all groups after watching the dental sealant message t88  = 5.81, p mix-framed message resulted in the highest scores. The gain-framed message was the least influential on four constructs. This finding is in contrast to findings that gain-framed oral health messages are most influential (Gallagher & Updegraff, 2012; O'Keefe & Jensen, 2007). Community advisory board members determined to use the mix-framed approach in an oral health social marketing campaign with a rural, American Indian audience. © 2015 Wiley Periodicals, Inc.

  19. Effect of artificial aging on the bond durability of fissure sealants.

    Science.gov (United States)

    Yun, Xiaofei; Li, Wei; Ling, Chen; Fok, Alex

    2013-06-01

    To evaluate the effect of artificial aging on the bond durability of fissure sealants in vitro. Twenty bovine incisors received 4 different sealant treatments and were divided into four groups: 1. Ultraseal XT plus (UX); 2. Enamel Loc (EL); 3. 35% phosphoric acid plus Enamel Loc (PEL); 4. Adper Prompt L-Pop plus Clinpro (PPC). Beam-shaped specimens were prepared and randomly divided into three subgroups. One subgroup underwent the microtensile bond strength (µTBS) test after 24-h storage in 37°C water. The other two subgroups were also subjected to the microtensile bond strength test after 5000 and 10,000 thermal cycles, respectively. Another twelve intact human third molars were sealed using 1 of 3 methods and were divided into 3 groups of 4 each: 1. Ultraseal XT plus; 2. Adper Prompt L-Pop plus Clinpro; and 3. Enamel Loc. Two specimens from each group were immersed in a 50% silver nitrate solution for 24 h, followed by exposure to fluorescent light for 8 h, before being scanned in a micro-CT (microcomputer tomography) machine. The other two were handled in the same way after undergoing 10,000 thermal cycles. The CT images obtained were evaluated. All samples from the EL group were broken during preparation, so no µTBS results were available. After 5000 thermal cycles, the bond strengths of the three other groups (UX, PEL, PPC) decreased significantly (p artificial aging. Micro-CT, a nondestructive analytical tool, may be used to evaluate the sealant/enamel interface effectively.

  20. Knowledge, value, opinion and practice about usage of pit and fissure sealant among dental professionals in Chennai, Tamil Nadu, India.

    Science.gov (United States)

    Nagappan, N; Dhamodhar, M Dinesh; Nithin, M G; Kumar, E Senthil

    2015-12-01

    A study was aimed to assess the knowledge, value, opinion, and practice regarding the use of dental sealants among private dental practitioners in Chennai, Tamil Nadu, India. A self-administrated questionnaire were distributed to 192 private dental practitioners in Chennai, Tamil Nadu, India by using simple random sampling. A convenience sampling technique was employed. The questionnaire consisted of 28 items, which included information about knowledge, value, opinion, and practice regarding dental sealants. The questionnaire was obtained from the study by San Martin et al. 2013 and Kailash Asawa et al. 2014. Frequency distribution was tabulated. For frequency distribution strongly, strongly agree, and agree were combined as "agree" and strongly disagree and disagree were combined as "disagree." There were no changes in "neutral." Among the 196 study subjects 56.2% were males and 43.8% were females with their clinical experience of 52.1% for 15 years. The mean scores for knowledge, value, opinion, and practice were 41.8 ± 3.7, 18.7 ± 2.8, 18.1 ± 1.4, and 12.9 ± 2.3, respectively. The results suggest that dental practitioners had satisfactory knowledge about pit and fissure sealant and had neutral attitudes about sealants being effective. Dental practitioners adequately used the pit and fissure sealants but they did not follow the standardized procedures and specific guidelines.

  1. Initial experience with a synthetic sealant PleuraSeal™ after pulmonary resections: a prospective study with retrospective case matched controls

    Directory of Open Access Journals (Sweden)

    Hennings Ellen

    2010-06-01

    Full Text Available Abstract The objective of this study was to evaluate postoperative outcome and efficacy of a hydrogel tissue sealant for prevention of alveolar leakage after open lung resections. 20 consecutive patients were enrolled in the PleuraSeal™ sealant group (PSG and case matched with 20 retrospective controls (CG with standard treatment. Assessment of postoperative air leakage was performed until chest tube removal. Patients were followed until 30 days after discharge. At end of surgery, 100% in the PSG and 0% in the CG were air leak free (p The study demonstrated a superior efficacy of PleuraSeal™ sealant compared with standard surgical treatment for sustained sealing of postoperative air leakage and causes shorter air leak chest tube duration.

  2. Chemically bonded phosphate ceramic sealant formulations for oil field applications

    Science.gov (United States)

    Wagh, Arun S [Naperville, IL; Jeong, Seung-Young [Taejon, KR; McDaniel, Richard [Crest Hill, IL

    2008-10-21

    A sealant for an oil or geothermal well capable of setting within about 3 to about 6 hours at temperatures less than about 250.degree. F. for shallow wells less than about 10,000 feet and deep wells greater than about 10,000 feet having MgO present in the range of from about 9.9 to about 14.5%, KH.sub.2PO.sub.4 present in the range of from about 29.7 to about 27.2%, class C fly ash present in the range of from about 19.8 to about 36.3%, class F fly ash present in the range of from about 19.8 to about 0%, boric acid or borax present in the range of from about 0.39 to about 1.45%, and water present in the range of from about 20.3 to about 21.86% by weight of the sealant.A method of sealing wells is disclosed as are compositions for very high temperature wells is disclosed as is a composition for treating oil field wastes.

  3. Use of a sealant to prevent prolonged air leaks after lung resection: a prospective randomized study

    Directory of Open Access Journals (Sweden)

    Lequaglie Cosimo

    2012-10-01

    Full Text Available Abstract Background Pulmonary air leaks are common complications of lung resection and result in prolonged hospital stays and increased costs. The purpose of this study was to investigate whether, compared with standard care, the use of a synthetic polyethylene glycol matrix (CoSeal® could reduce air leaks detected by means of a digital chest drain system (DigiVent™, in patients undergoing lung resection (sutures and/or staples alone. Methods Patients who intraoperatively showed moderate or severe air leaks (evaluated by water submersion tests were intraoperatively randomized to receive just sutures/staples (control group or sutures/staples plus CoSeal® (sealant group. Differences among the groups in terms of air leaks, prolonged air leaks, time to chest tube removal, length of hospital stay and related costs were assessed. Results In total, 216 lung resection patients completed the study. Nineteen patients (18.1% in the control group and 12 (10.8% patients in the sealant group experienced postoperative air leaks, while a prolonged air leak was recorded in 11.4% (n = 12 of patients in the control group and 2.7% (n = 3 of patients in the sealant group. The difference in the incidence of air leaks and prolonged air leaks between the two groups was statistically significant (p = 0.0002 and p = 0.0013. The mean length of hospital stay was significantly shorter in the sealant group (4 days than the control group (8 days (p = 0.0001. We also observed lower costs in the sealant group than the control group. Conclusion The use of CoSeal® may decrease the occurrence and severity of postoperative air leaks after lung resection and is associated with shorter hospital stay. Trial registration Not registered. The trial was approved by the Institutional Review Board of the IRCCS-CROB Basilicata Regional Cancer Institute, Rionero in Vulture, Italy.

  4. Fibrin sealants or cell saver eliminate the need for autologous blood donation in anemic patients undergoing primary total knee arthroplasty.

    Science.gov (United States)

    Bou Monsef, Jad; Buckup, Johannes; Waldstein, Wenzel; Cornell, Charles; Boettner, Friedrich

    2014-01-01

    Reducing allogeneic blood transfusions remains a challenge in total knee arthroplasty. Patients with preoperative anemia have a particularly high risk for perioperative blood transfusions. 176 anemic patients (Hb < 13.5 g/dl) undergoing total knee replacement were prospectively evaluated to compare the effect of a perioperative cell saver (26 patients), intraoperative fibrin sealants (5 ml Evicel, Johnson & Johnson Wound Management, Ethicon, Somerville, NJ) (45 patients), preoperative autologous blood donation (PABD) (21 patients), the combination of fibrin sealants and preoperative autologous blood donation (44) and no intervention (40 patients) on perioperative blood loss and transfusion requirements. All protocols resulted in significant reduction of allogeneic blood transfusions. Transfusion rates were similar with the use of PABD (19%), Evicel (18%), and cell saver (19%), all significantly lower than the control group (38 %, p < 0.05). Combining Evicel with PABD resulted in significantly higher wastage of autologous units (p < 0.05) with no significant reduction in allogeneic transfusion rate (14%). The use of fibrin sealant resulted in a significant reduction of blood loss compared to the PABD group (603 vs. 810 ml, p < 0.005) as well as the control group (603 vs. 822 ml, p < 0.005). While PABD proved to be the most cost-effective treatment option in anemic patients, fibrin sealants and cell saver show similar reduction in allogeneic transfusion rates compared to controls. The combination of fibrin sealants and PABD is not cost-effective and increases the number of wasted units.

  5. A randomised trial of lung sealant versus medical therapy for advanced emphysema

    NARCIS (Netherlands)

    Come, Carolyn E.; Kramer, Mordechai R.; Dransfield, Mark T.; Abu-Hijleh, Muhanned; Berkowitz, David; Bezzi, Michela; Bhatt, Surya P.; Boyd, Michael B.; Cases, Enrique; Chen, Alexander C.; Cooper, Christopher B.; Flandes, Javier; Gildea, Thomas; Gotfried, Mark; Hogarth, D. Kyle; Kolandaivelu, Kumaran; Leeds, William; Liesching, Timothy; Marchetti, Nathaniel; Marquette, Charles; Mularski, Richard A.; Pinto-Plata, Victor M.; Pritchett, Michael A.; Rafeq, Samaan; Rubio, Edmundo R.; Slebos, Dirk-Jan; Stratakos, Grigoris; Sy, Alexander; Tsai, Larry W.; Wahidi, Momen; Walsh, John; Wells, J. Michael; Whitten, Patrick E.; Yusen, Roger; Zulueta, Javier J.; Criner, Gerard J.; Washko, George R.

    Uncontrolled pilot studies demonstrated promising results of endoscopic lung volume reduction using emphysematous lung sealant (ELS) in patients with advanced, upper lobe predominant emphysema. We aimed to evaluate the safety and efficacy of ELS in a randomised controlled setting. Patients were

  6. INVESTIGATION OF THE POTENTIAL ANTIMICROBIAL EFFICACY OF SEALANTS USED IN HVAC SYSTEMS

    Science.gov (United States)

    The paper gives results of an investigation of the potential antimicrobial efficacy of sealants used in heating, ventilation and air-conditioning systems. Recent experiments confirm field experience that duct cleaning alone may not provide adequate protection from regrowth of fu...

  7. Fixation of osteochondral fractures in rabbit knees. A comparison of Kirschner wires, fibrin sealant, and polydioxanone pins.

    Science.gov (United States)

    Plaga, B R; Royster, R M; Donigian, A M; Wright, G B; Caskey, P M

    1992-03-01

    We compared fibrin sealant, polydioxanone (PDS) pins and Kirschner wires in the fixation of osteochondral fractures in rabbit knees. Standardised osteochondral fractures of the right medial femoral condyle were made in 56 adult New Zealand white rabbits. There were equal groups of control knees, and those which had Kirschner-wire, fibrin-sealant or PDS-pin fixation. No external immobilisation was used. One animal from each group was killed at two, three and four weeks. The remaining rabbits were killed at six weeks. A fracture which healed with less than 1 mm of displacement was considered a success. There was successful healing in 29% of the control group, in all of the Kirschner-wire group, in 50% of the fibrin-sealant group, and in 86% of the PDS-pin group. The use of PDS pins appears to be a reliable alternative to the use of metal in the fixation of osteochondral fractures in rabbits.

  8. Design approach to sealant selection for the life of the well

    NARCIS (Netherlands)

    Bosma, M.; Ravi, K.; Driel, W.D. van; Schreppers, G.M.A.

    1999-01-01

    Recent experience in the field has demonstrated that the mechanical properties of the annular sealant are a critical factor in the success of a well. A demanding operational regime of the well such as High Pressure/High Temperature (HP/HT) and well interventions, e.g. pressure testing stimulation,

  9. Evaluation of asbestos exposure within the automotive repair industry: a study involving removal of asbestos-containing body sealants and drive clutch replacement.

    Science.gov (United States)

    Blake, Charles L; Dotson, G Scott; Harbison, Raymond D

    2008-12-01

    Two independent assessments were performed of airborne asbestos concentrations generated during automotive repair work on vintage vehicles . The first involved removal of asbestos-containing seam sealant, and the second involved servicing of a drive clutch. Despite the relatively high concentrations (5.6-28%) of chrysotile fibers detected within bulk samples of seam sealant, the average asbestos concentration for personal breathing zone (PBZ) samples during seam sealant removal was 0.006 f/cc (fibers/cubic centimeter of air). Many other air samples contained asbestos at or below the analytical limit of detection (LOD). Pneumatic chiseling of the sealant material during removal resulted in 69% of area air samples containing asbestos. Use of this impact tool liberated more asbestos than hand scraping. Asbestos fibers were only detected in air samples collected during the installation of a replacement clutch. The highest asbestos corrected airborne fiber concentration observed during clutch installation was 0.0028 f/cc. This value is approximately 100 times lower than Occupational Safety and Health Administration's (OSHA) permissible exposure limit (PEL) of 0.1f/cc. The airborne asbestos concentrations observed during the servicing of vintage vehicles with asbestos-containing seam sealant and clutches are comparable to levels reported for repair work involving brake components and gaskets.

  10. Clinical performance of a glass ionomer sealant protected with two different resin-based agents over a 2-year follow-up period.

    Science.gov (United States)

    Ulusoy, A T; Tunc, E S; Bayrak, Ş

    2017-03-01

    To evaluate the effects of two different resin coating materials on the clinical performance of a conventional glass ionomer sealant. Permanent first mandibular molars of 60 children aged 6-9 years were sealed with Fuji VII. In each child, G-Coat Plus coating agent was applied to molars on one side and Heliobond coating agent to molars on the opposite side of the mouth. Clinical evaluations were carried out at 1, 6, 12, 18 and 24 months after sealant and coating application. At 1, 6, 12, 18 and 24 months after sealant and coating application, total sealant retention rates were 88%, 40%, 19%, 15% and 9% for molars coated with G-Coat Plus, and 93%, 47%, 17%, 15% and 7% for those coated with Heliobond. The differences between the two coating agents were not statistically significant (p>0.05). No incidence of caries was observed in either group during the two-year evaluation period. Wilcoxon signed rank test was used to compare differences in retention rates and caries incidence by coating agent. Although retention rates of Fuji VII were relatively low and similar for both resin coating agents tested, dental caries were not observed in either group during the 24-month study period. In children with a high risk of caries and partially erupted molars, the use of a glass ionomer sealant with a resin-based coating agent should be encouraged.

  11. Randomized clinical trial of fibrin sealant versus titanium tacks for mesh fixation in laparoscopic umbilical hernia repair

    DEFF Research Database (Denmark)

    Eriksen, J R; Bisgaard, T; Assaadzadeh, S

    2011-01-01

    The use of tacks for mesh fixation may induce pain after surgery for ventral hernia. The aim of this study was to compare postoperative pain after laparoscopic ventral hernia repair (LVHR) with conventional mesh fixation using titanium tacks versus fibrin sealant (FS).......The use of tacks for mesh fixation may induce pain after surgery for ventral hernia. The aim of this study was to compare postoperative pain after laparoscopic ventral hernia repair (LVHR) with conventional mesh fixation using titanium tacks versus fibrin sealant (FS)....

  12. Dental sealants and restorations and urinary bisphenol A concentrations in children in the 2003-2004 National Health and Nutrition Examination Survey.

    Science.gov (United States)

    McKinney, Christy; Rue, Tessa; Sathyanarayana, Sheela; Martin, Michael; Seminario, Ana Lucia; DeRouen, Timothy

    2014-07-01

    Resin-based dental sealants and composites contain bisphenol A-glycidyl methacrylate, a bisphenol A (BPA) derivative. The authors hypothesized that a greater number of sealants or restorations would be associated with higher urinary BPA concentrations. The authors examined urinary BPA measurements (in nanograms per milliliter) and oral examination data for 1,001 children aged 6 to 19 years from data sets of the 2003-2004 National Health and Nutrition Examination Survey (NHANES). They categorized children according to number of occlusal sealants and number of restorations, with four categories in each of the two groups. They estimated associations by using unadjusted and adjusted tobit regression models. The lowest quartile of BPA concentrations ranged from 0.3 ng/mL to 1.9 ng/mL, whereas the highest quartile ranged from 7.3 ng/mL to 149 ng/mL. In adjusted analysis, children with seven to 16 sealants had geometric mean BPA concentrations 25 percent higher than those of children with no sealants (95 percent confidence interval [CI], -14 percent to 82 percent; P = .23). In adjusted analysis, children with seven to 42 restorations had geometric mean BPA concentrations 20 percent higher than those of children with no restorations (95 percent CI, -6 percent to 53 percent; P = .13). Neither of these adjusted estimates was statistically significant. Though the findings were in the direction hypothesized, the authors did not observe a statistically significant association between a greater number of sealants or restorations and higher urinary BPA concentrations. Additional studies are needed to determine the extent of oral and systemic exposure to BPA from resin-based dental restorative materials over time. Dentists should follow this issue carefully as it develops and as the body of evidence grows. There is insufficient evidence to change practice at this time.

  13. Efficacy of a Self-expanding Tract Sealant Device in the Reduction of Pneumothorax and Chest Tube Placement Rates After Percutaneous Lung Biopsy: A Matched Controlled Study Using Propensity Score Analysis

    Energy Technology Data Exchange (ETDEWEB)

    Ahrar, Judy U., E-mail: judy.ahrar@mdanderson.org; Gupta, Sanjay [The University of Texas M.D. Anderson Cancer Center, Department of Interventional Radiology (United States); Ensor, Joe E. [Houston Methodist Research Institute, The Houston Methodist Cancer Center (United States); Mahvash, Armeen; Sabir, Sharjeel H.; Steele, Joseph R.; McRae, Stephen E.; Avritscher, Rony; Huang, Steven Y.; Odisio, Bruno C.; Murthy, Ravi; Ahrar, Kamran; Wallace, Michael J.; Tam, Alda L. [The University of Texas M.D. Anderson Cancer Center, Department of Interventional Radiology (United States)

    2017-02-15

    PurposeTo evaluate the use of a self-expanding tract sealant device (BioSentry™) on the rates of pneumothorax and chest tube insertion after percutaneous lung biopsy.Materials and MethodsIn this retrospective study, we compared 318 patients who received BioSentry™ during percutaneous lung biopsy (treated group) with 1956 patients who did not (control group). Patient-, lesion-, and procedure-specific variables, and pneumothorax and chest tube insertion rates were recorded. To adjust for potential selection bias, patients in the treated group were matched 1:1 to patients in the control group using propensity score matching based on the above-mentioned variables. Patients were considered a match if the absolute difference in their propensity scores was ≤equal to 0.02.ResultsBefore matching, the pneumothorax and chest tube rates were 24.5 and 13.1% in the control group, and 21.1 and 8.5% in the treated group, respectively. Using propensity scores, a match was found for 317 patients in the treatment group. Chi-square contingency matched pair analysis showed the treated group had significantly lower pneumothorax (20.8 vs. 32.8%; p = 0.001) and chest tube (8.2 vs. 20.8%; p < 0.0001) rates compared to the control group. Sub-analysis including only faculty who had >30 cases of both treatment and control cases demonstrated similar findings: the treated group had significantly lower pneumothorax (17.6 vs. 30.2%; p = 0.002) and chest tube (7.2 vs. 18%; p = 0.001) rates.ConclusionsThe self-expanding tract sealant device significantly reduced the pneumothorax rate, and more importantly, the chest tube placement rate after percutaneous lung biopsy.

  14. Behavior of adhesion forces of silicone adhesive sealants and mastic butyl under the influence of ionizing radiation

    International Nuclear Information System (INIS)

    Costa, Wanderley da

    2012-01-01

    Adhesives are products that can keep materials together by bonds between the surfaces. Sealants are products that can keep filled a space between two surfaces, through a barrier that is configured as a 'bridge' between the two surfaces. The mastic is a product made of a mixture of substances with the primary butyl polymer, with the consistency of a mass not dried that can be used as a sealant. The polysiloxane, also known as silicone are the most important synthetic polymers with inorganic structure, and are matrices of silicone adhesive sealants. To demonstrate the behavior of the adhesive forces of these products under different conditions, we used five different techniques. These products were subjected to two different conditions to verify the behavior of adhesion, one at the environmental condition and another under the ionizing radiation. The results showed not only differences between products (silicone and mastic), but also that the adhesive forces have different behaviors under the conditions which the samples were subjected. With this was reached the goal of this study that aspired show the differences between the mastic and silicone, this last one is often considered - erroneously - the same as mastic. Thus it was proven that: 1. silicone can be regarded as an adhesive and a sealant at ambient conditions, 2. mastic improves substantially adhesion in an environment of ionizing radiation and this property can be an excellent alternative to the adhesive market. (author)

  15. A 12-month clinical evaluation of pit-and-fissure sealants placed with and without etch-and-rinse and self-etch adhesive systems in newly-erupted teeth

    Directory of Open Access Journals (Sweden)

    Maryam Karami Nogourani

    2012-06-01

    Full Text Available OBJECTIVES: The objective of this one-year clinical study was to investigate the effect of two adhesive systems (Adper Single Bond, a two-step etch-and-rinse and Clearfil SE Bond, a two-step self-etch system on pit-and-fissure sealant retention in newly-erupted teeth. This study compared the success of the sealants in mesial and distopalatal grooves with and without these two adhesive systems. MATERIAL AND METHODS: In a clinical trial, 35 children aged 6-8 years undergoing sealant placement were recruited. This one-year clinical study scored 70 mesial and 70 distopalatal sealants of newly-erupted permanent maxillary first molar, with a split-mouth design. All children received sealant alone in one permanent maxillary molar tooth. Children were randomized into two groups. One group received Self-etch (Se bond plus sealant and the other group received Single Bond plus sealant in another permanent maxillary molar tooth. Clinical evaluation at 3, 6 and 12 months was performed and the retention was studied in terms of the success and failure. RESULTS: The success rate of sealant in the distopalatal groove, using SeB at 3, 6 and 12 months was 93.3% (95% CI: 68.0, 99.8, 73.3% (95% CI: 44.9, 92.2 and 66.7% (95% CI: 38.4, 88.2, respectively. It was greater than that of the distopalatal groove in SB group with a success rate of 62.5% (95% CI: 35.4, 84.8, 31.3% (95% CI: 11.8, 58.7 and 31.3% (95% CI: 11.8, 58.7, at the three evaluation periods. The success rate of sealant in the mesial groove using SeB was 86.6% (95% CI: 59.5, 98.3, 53.3% (95% CI: 26.6, 78.7 and 53.3% (95% CI: 26.6, 78.7, while this was 100% (95% CI: 79.4, 100.0, 81.3% (95% CI: 54.4, 96.0 and 81.3% (95% CI: 54.4, 96.0 using SB, at 3, 6 and 12-month evaluation periods. CONCLUSIONS: These results support the use of these two bonding agents in pit-and-fissure sealants under both isolated and contaminated conditions. Further, Se bond seemed to be less sensitive to moisture contamination.

  16. Durability of sealants exposed to outdoor weathering and hot compression cycles

    Science.gov (United States)

    Gregory T. Schueneman; Steven Lacher; Christopher G. Hunt; Christopher C. White; Donald L. Hunston

    2011-01-01

    Sealants play an important role in weatherproofing structures by filling gaps and preventing air and water intrusion. When incorrectly selected or improperly applied, they may fail quickly, compromising durability of the structure. To ensure reliability and prevent the need for costly repairs to structures, it is necessary to measure durability and predict life...

  17. Characterization of low temperature creep properties of crack sealants using bending beam rehometry.

    Science.gov (United States)

    2009-11-01

    Crack sealing has been widely used as a routine preventative maintenance practice. Given its proper installation, crack sealants can extend : pavement service life by three to five years. However, current specifications for the selection of crack sea...

  18. Packaging of microwave integrated circuits operating beyond 100 GHz

    Science.gov (United States)

    Samoska, L.; Daniel, E.; Sokolov, V.; Sommerfeldt, S.; Bublitz, J.; Olson, K.; Gilbert, B.; Chow, D.

    2002-01-01

    Several methods of packaging high speed (75-330 GHz) InP HEMT MMIC devices are discussed. Coplanar wirebonding is presented with measured insertion loss of less than 0.5dB and return loss better than -17 dB from DC to 110 GHz. A motherboard/daughterboard packaging scheme is presented which supports minimum loss chains of MMICs using this coplanar wirebonding method. Split waveguide block packaging approaches are presented in G-band (140-220 GHz) with two types of MMIC-waveguide transitions: E-plane probe andantipodal finline.

  19. Combination of heterologous fibrin sealant and bioengineered human embryonic stem cells to improve regeneration following autogenous sciatic nerve grafting repair.

    Science.gov (United States)

    Mozafari, Roghayeh; Kyrylenko, Sergiy; Castro, Mateus Vidigal; Ferreira, Rui Seabra; Barraviera, Benedito; Oliveira, Alexandre Leite Rodrigues

    2018-01-01

    Peripheral nerve injury is a worldwide clinical problem, and the preferred surgical method for treating it is the end-to-end neurorrhaphy. When it is not possible due to a large nerve gap, autologous nerve grafting is used. However, these surgical techniques result in nerve regeneration at highly variable degrees. It is thus very important to seek complementary techniques to improve motor and sensory recovery. One promising approach could be cell therapy. Transplantation therapy with human embryonic stem cells (hESCs) is appealing because these cells are pluripotent and can differentiate into specialized cell types and have self-renewal ability. Therefore, the main objective of this study was to find conditions under which functional recovery is improved after sciatic nerve neurorrhaphy. We assumed that hESC, either alone or in combination with heterologous fibrin sealant scaffold, could be used to support regeneration in a mouse model of sciatic nerve injury and repair via autografting with end-to-end neurorrhaphy. Five millimeters of the sciatic nerve of C57BL/6 J mice were transected off and rotated 180 degrees to simulate an injury, and then stumps were sutured. Next, we applied heterologous fibrin sealant and/or human embryonic stem cells genetically altered to overexpress fibroblast growth factor 2 (FGF2) at the site of the injury. The study was designed to include six experimental groups comprising neurorrhaphy (N), neurorrhaphy + heterologous fibrin sealant (N + F), neurorrhaphy + heterologous fibrin sealant + doxycycline (N + F + D), neurorrhaphy + heterologous fibrin sealant + wild-type hESC (N + F + W), neurorrhaphy + heterologous fibrin sealant + hESC off (N + F + T), and neurorrhaphy + heterologous fibrin sealant + hESC on via doxycycline (N + F + D + T). We evaluated the recovery rate using Catwalk and von Frey functional recovery tests, as well as immunohistochemistry analysis. The experiments indicated that

  20. Clinical effectiveness and cost-effectiveness of fissure sealants in children and adolescents with a high caries risk

    Directory of Open Access Journals (Sweden)

    Neusser, Silke

    2014-10-01

    Full Text Available [english] In Germany, the application of resin-based pits and fissures sealants on the occlusal surfaces of permanent molars is part of individual prophylaxis for children and adolescents between six and 18 years. The individual prophylaxis is covered by the Statutory Health Insurance since 1993.The report addresses questions on medical effectiveness, cost-effectiveness, as well as ethical, social, and legal implications of pit and fissure sealants in preventing dental caries for children and adolescents at high caries risk. The results of the studies indicate a protective effect of pit and fissure sealants, particularly for children and adolescents at high caries risk. Additionally, the economic evaluation suggests a tendency for cost savings in this group. Nevertheless, a general expansion of the intervention cannot be recommended. All studies show a risk of bias in favour of pit and fissure sealing and a limited transferability to the German health care system. Studies included in the economic evaluation revealed methodological flaws. Both the economic models and primary studies do not provide reliable results.

  1. Color and opacity of composites protected with surface sealants and submitted to artificial accelerated aging.

    Science.gov (United States)

    Aguilar, Fabiano Gamero; Roberti Garcia, Lucas da Fonseca; Cruvinel, Diogo Rodrigues; Sousa, Ana Beatriz Silva; de Carvalho Panzeri Pires-de-Souza, Fernanda

    2012-01-01

    To evaluate the color similarity, stability and opacity of composites (TPH, Charisma, and Concept, shade A2) protected with surface sealants (Fortify Plus and Biscover) and cyanoacrylate (Super Bonder). Forty specimens of each composite were made and separated into 4 groups (n=10) according to the surface protection: GI - without sealant; GII - cyanoacrylate; GIII - Fortify Plus; GIV - Biscover. Color and opacity readings were taken before and after Artificial Acelerated Aging (AAA) and the values obtained for color stability were submitted to statistical analysis by 2-way ANOVA and Bonferroni's test (P<.05). The values acquired for color similarity were submitted to 1-way ANOVA and Tukey's test (P<.05). The specimen sufaces were compared before and after AAA using Scanning Electronic Microscopy (SEM). Studied composites did not present the same values for the coordinates L*, a* and b * before AAA, indicating that there was no color similarity among them. All composites presented color alteration after AAA with clinically unacceptable values. Protected groups presented lower opacity variation after AAA, in comparison with the control goup. SEM evaluation demonstrated that AAA increased the surface irregularities in all of the studied groups. Surface sealants were not effective in maintaining composite color, but were able to maintain opacity.

  2. Percutaneous BioOrganic Sealing of Duodenal Fistulas: Case Report and Review of Biological Sealants with Potential Use in Interventional Radiology

    Energy Technology Data Exchange (ETDEWEB)

    Wadhwa, Vibhor, E-mail: vwadhwa1@jhmi.edu [Johns Hopkins University School of Medicine, Division of Vascular & Interventional Radiology (United States); Leeper, William R., E-mail: rob.leeper@jhmi.edu [Johns Hopkins University School of Medicine, Department of Surgery (United States); Tamrazi, Anobel, E-mail: atamraz1@jhmi.edu [Johns Hopkins University School of Medicine, Division of Vascular & Interventional Radiology (United States)

    2015-08-15

    Biological sealants are being increasingly used in a variety of surgical specialties for their hemostatic and sealing capabilities. However, their use in interventional radiology has not been widely reported. The authors describe a case of duodenal perforation occurring after 15 years of gastric bypass surgery, in whom surgical diversion was unsuccessfully attempted and the leakage was successfully controlled using percutaneous administration of a combination of biological and organic sealants.

  3. THE STATE AND PERSPECTIVE OF HERMETIZATION OF UNDERGROUND STRUCTURES WITH USE OF RUBBER SEALANTS

    Directory of Open Access Journals (Sweden)

    V. I. Leshchenko

    2010-03-01

    Full Text Available The works on creation of effective rubber sealants for hermetic sealing of joints of underground structures from modular ferroconcrete and pig-iron, including tunnel elements for the underground, are carried out.

  4. PAH concentrations in lake sediment decline following ban on coal-tar-based pavement sealants in Austin, Texas

    Science.gov (United States)

    Van Metre, Peter C.; Mahler, Barbara J.

    2013-01-01

    Recent studies have concluded that coal-tar-based pavement sealants are a major source of polycyclic aromatic hydrocarbons (PAHs) in urban settings in large parts of the United States. In 2006, Austin, TX, became the first jurisdiction in the U.S. to ban the use of coal-tar sealants. We evaluated the effect of Austin’s ban by analyzing PAHs in sediment cores and bottom-sediment samples collected in 1998, 2000, 2001, 2012, and 2014 from Lady Bird Lake, the principal receiving water body for Austin urban runoff. The sum concentration of the 16 EPA Priority Pollutant PAHs (∑PAH16) in dated core intervals and surficial bottom-sediment samples collected from sites in the lower lake declined about 44% from 1998–2005 to 2006–2014 (means of 7980 and 4500 μg kg–1, respectively), and by 2012–2014, the decline was about 58% (mean of 3320 μg kg–1). Concentrations of ∑PAH16 in bottom sediment from two of three mid-lake sites decreased by about 71 and 35% from 2001 to 2014. Concentrations at a third site increased by about 14% from 2001 to 2014. The decreases since 2006 reverse a 40-year (1959–1998) upward trend. Despite declines in PAH concentrations, PAH profiles and source-receptor modeling results indicate that coal-tar sealants remain the largest PAH source to the lake, implying that PAH concentrations likely will continue to decline as stocks of previously applied sealant gradually become depleted.

  5. The effect of different enamel surface treatments on microleakage of fissure sealants

    Directory of Open Access Journals (Sweden)

    Asli Topaloglu-Ak

    2013-11-01

    Full Text Available Objective. The aim of this study was to evaluate the effects of different techniques of surface treatment on the microleakage of fissure sealants in permanent molar teeth in vitro. Materials and methods. 96 extracted impacted human third molars were randomly divided into 8 surface treatment groups (n=12/group as 1. Er: YAG laser; (Fidelis II, Fotona, Ljubljana, Slovenia (125 mj, 20Hz. 2. Er: YAG laser + 37% H3PO4 (15s; 3. ER: AG laser + 37% H3PO4+Prime&Bond NT; 4. Er: YAG laser + G Bond; 5. Er: YAG laser + Prime&Bond NT; 6. 37% H3PO4; 7. 37% H3PO4 + Prime &Bond NT; 8. G Bond. Sealant material (Clinpro, 3M ESPE, Seefeld, Germany, was applied into the fissures and light-cured for 20s with LED (Bluephase C5, Ivoclar-Vivadent, Schaan, Liechtenstein. Specimens were subjected to thermocycling (1000×, 5-55°C, dwell time: 15s and immersed in 0.5% basic fuchsin solution for 24h at 37°C. The samples were sectioned and scored on a 3 point rating scale using a light microscope with a magnification of ×20. One-way analysis of variance was used to analyze data. Multiple comparisons were analyzed using Bonferroni test (p=0.05. Results. Er:YAG laser showed the highest microleakage scores whereas Er YAG laser + 37% H3PO4 showed the lowest. Although 37% H3PO4 group showed higher scores than Er:YAG laser + 37% H3PO4, the difference was not statistically significant. Conclusion. Etching fissures with phosphoric acid is sufficient prior to fissure sealant application.

  6. Aluminosilicate-based sealants for SOFCs and other electrochemical applications - A brief review

    Science.gov (United States)

    Tulyaganov, Dilshat U.; Reddy, Allu Amarnath; Kharton, Vladislav V.; Ferreira, José M. F.

    2013-11-01

    Among different designs of solid oxide fuel cells (SOFCs), planar design is the most promising due to easier fabrication, improved performance and relatively high power density. In planar SOFCs and other solid-electrolyte devices, gas-tight seals must be formed along the edges of each cell and between the stack and gas manifolds. For a sealant to work effectively in high-temperature SOFC environment, equilibrium needs to be achieved amid its mechanical properties and flow behavior so that it does not only maintain its hermeticity at high temperature but is also able to reduce mechanical stresses generated in the seal during thermal cycling. The most common sealants based on glass or glass-ceramic materials have been shown to operate in fuel cells for more than 1000 h with no significant degradation. Analysis of the current literature sources demonstrated that from thermal and chemical stability points of view, silicate based glass systems are more suitable than borate and borosilicate glass systems. In this work, different glass-ceramic (GC) compositions based on alkaline- and alkaline-earth aluminosilicate-based glass systems are reviewed with a special emphasis on their thermal, chemical, mechanical, and electrical properties. Based on these considerations, glass composition design approaches are provided that aid in search of the best seal glasses satisfying the rigid functional requirements. Among all the glass systems studied, a pyroxene based CaO-MgO-SrO-BaO-La2O3-Al2O3-SiO2 seal GC compositions have been specifically discussed because those have achieved appropriate thermal and chemical properties along with high stability. Approaches for further developments and optimization of GC sealants are briefly discussed.

  7. Effectiveness of Fibrin Sealant Patch in Reducing Drain Volume after Pelvic Lymph Node Dissection in Women with Gynecologic Malignancy

    Directory of Open Access Journals (Sweden)

    Hwa Cheong Kim

    2017-01-01

    Full Text Available Background. The goal of this study was to evaluate the effectiveness of fibrin sealant in decreasing postoperative lymphatic drainage in women after pelvic lymphadenectomy and/or para-aortic lymphadenectomy during gynecologic cancer surgery. Methods. This study is a retrospective case-control study. Forty-five patients who underwent staging surgery were enrolled. Twenty-seven patients were in the fibrin sealant group (group A and 18 in the control group (group B. The two groups were compared for the total volume of drain, hospital stay, harvested lymph node, and incidence of asymptomatic lymphocele. Lymphocele formation was evaluated by computed tomography (CT on 3 months after surgery. Results. There were no significant differences in patient demographics between group A and B with respect to age, BMI, and harvested lymph nodes. Patients who received fibrin sealants had reduced total volume of drainage from postoperative days 2 to 5 compared to the control group (group A versus group B: 994.819±745.85 ml versus 1847.89±1241.41 ml; P=0.015. However no differences were observed in hospital stay (P=0.282, duration of drain (P=0.207, and incidence of asymptomatic lymphocele at 3 months (P=0.126. Conclusion. The results of this study indicate that the application of fibrin sealants after pelvic and/or para-aortic lymphadenectomy may reduce lymphatic drainage in gynecologic malignancy.

  8. Development of packagings for 'MONJU' blanket fuel assemblies

    International Nuclear Information System (INIS)

    Shibata, Kan; Ouchi, Yuichiro; Matsuzaki, Masaaki; Okuda, Yoshihisa

    1995-01-01

    Blanket assemblies for prototype Fast Breeder Reactor 'MONJU' are made at commercial fuel fabrication plants capable of handling deplete Uranium in Japan. For the purpose of transport the assemblies are inserted into a packaging that is set horizontally at the fabrication plants because of compatibility with equipment installed at the plants. On the other hand, the assemblies must be taken out from the packaging set vertically at 'MONJU' due to compatibility. For this reason development of a new packaging, which makes it possible to take assemblies in and out both horizontally and vertically, is needed to carry out transport of assemblies for reload. The development and fabrication of the packagings, taking about two years, were completed in March 1995. The packagings were used in transport of assemblies in June 1995 for the first change. This report introduces the outline of the packaging and confirmation tests done in the process of development. (author)

  9. No difference in sexual dysfunction after transabdominal preperitoneal (TAPP) approach for inguinal hernia with fibrin sealant or tacks for mesh fixation

    DEFF Research Database (Denmark)

    Pommergaard, H C; Burcharth, J; Andresen, K

    2017-01-01

    BACKGROUND: Postoperative sexual dysfunction in relation to laparoscopic groin hernia surgery may be related to methods of mesh fixation. However, this has not been investigated earlier. Moreover, results regarding sexual dysfunction in females have not been reported systematically. The aim...... of this study was to compare fibrin sealant versus tacks for fixation of mesh regarding sexual dysfunction in males and females. METHODS: Using the Danish Hernia Database, patients operated laparoscopically for groin hernia with a transabdominal preperitoneal (TAPP) procedure with fibrin sealant or tacks...... for mesh fixation were sent a questionnaire regarding sexual dysfunction. Sexually active patients without recurrence were evaluated in this study. RESULTS: Pain during sexual activity was present in 115 of 1019 (11.3 %) males and 17 of 147 (11.6 %) females. There was no difference between fibrin sealant...

  10. Dual Use of Packaging on the Moon: Logistics-2-Living

    Science.gov (United States)

    Howe, A. Scott; Howard, Robert

    2010-01-01

    This paper describes a modular packaging system for logistics that can be reconfigured into internal outfitting for a lunar outpost, including desks, chairs, partitions, cabinets, and radiation shielding. Logistics include clothes, equipment, food, and other consumables needed to sustain the crew for the duration of the mission. A significant mass penalty is required for the packaging and handling of logistics for re-supply of short to long-term space missions that must be brought out of the gravity well on a launch vehicle. Once the supplies have been exhausted, the packaging material is typically of no further use and is discarded. If a scheme can be developed that reuses the logistics packaging, the mass penalty can be reduced. In this research, a modular packaging system has been devised as a kit-of-parts that can be used for both handling logistics supplies, and then reconfigured into desks, chairs, partitions, cabinets, and radiation shielding. The system is derived from a standard International Space Station (ISS)-type Cargo Transfer Bag (CTB), using soft, unfoldable box-like containers with stiff metal inserts. The empty hydrogen-impregnated CTBs can be used as-is for cabinets, opened up for use as partitions, or draped over the habitat as layers of radiation shielding. Stiff metal inserts can be reconfigured into desks and other useful outfitting.

  11. Effect of dry period length on the effect of an intramammary teat sealant on the risk of mastitis in cattle treated with antibiotics at drying off.

    Science.gov (United States)

    Laven, R A; Balcomb, C C; Tulley, W T; Lawrence, K E

    2014-07-01

    The aim of this study was to evaluate, under farm conditions, the use of a teat sealant in addition to whole herd dry cow antibiotic therapy on the risk of clinical mastitis in dairy cattle at pasture, and to evaluate the impact of dry period length on that risk and the impact of the teat sealant on that risk. Dairy cows in three herds which used routine whole herd antibiotic therapy were randomly assigned to receive either treatment with an internal teat sealant (n=322) or no additional treatment (n=313) at drying-off between March and May 2010. All clinical mastitis cases during the dry period and to the end of the subsequent lactation were recorded by farm staff; factors affecting risk of clinical mastitis were then analysed using a Cox proportional hazards model. Median duration of the dry period was 112 days with >25% of cows having a dry period >130 days. The incidence risk of mastitis during lactation for cows treated with teat sealant was 9.9 (95% CI=6.9-13.7) cases per 100 cows compared with 17.9 (95% CI=13.8-22.6) cases per 100 cows for cows treated with antibiotic alone. The addition of a teat sealant to dry cow antibiotic therapy decreased the risk of clinical mastitis only in the first 33 days after calving (Hazard risk 0.24 (95% CI=0.12-0.48)). Length of dry period did not significantly affect the risk of clinical mastitis, or the effect of adding teat sealant to dry cow antibiotic therapy on the risk of clinical mastitis. In these herds where, based on the mastitis history, whole herd antibiotic therapy had been recommended, the use of a teat sealant significantly reduced the risk of clinical mastitis. This effect was limited to the first 33 days after calving; subsequently there was no significant effect of treatment. There was no effect of dry period length on risk of clinical mastitis, nor any significant interaction with treatment. Combination therapy with teat sealant and antibiotic was effective under New Zealand conditions in herds using whole

  12. Autologous fibrin sealant (Vivostat®) in the neurosurgical practice: Part I: Intracranial surgical procedure

    Science.gov (United States)

    Graziano, Francesca; Certo, Francesco; Basile, Luigi; Maugeri, Rosario; Grasso, Giovanni; Meccio, Flavia; Ganau, Mario; Iacopino, Domenico G.

    2015-01-01

    Background: Hemorrhages, cerebrospinal fluid (CSF) fistula and infections are the most challenging postoperative complications in Neurosurgery. In this study, we report our preliminary results using a fully autologous fibrin sealant agent, the Vivostat® system, in achieving hemostasis and CSF leakage repair during cranio-cerebral procedures. Methods: From January 2012 to March 2014, 77 patients were studied prospectively and data were collected and analyzed. Autologous fibrin sealant, taken from patient's blood, was prepared with the Vivostat® system and applied on the resection bed or above the dura mater to achieve hemostasis and dural sealing. The surgical technique, time to bleeding control and associated complications were recorded. Results: A total of 79 neurosurgical procedures have been performed on 77 patients. In the majority of cases (98%) the same autologous fibrin glue provided rapid hemostasis and dural sealing. No patient developed allergic reactions or systemic complications in association with its application. There were no cases of cerebral hematoma, swelling, infection, or epileptic seizures after surgery whether in the immediate or in late period follow-up. Conclusions: In this preliminary study, the easy and direct application of autologous fibrin sealant agent helped in controlling cerebral bleeding and in providing prompt and efficient dural sealing with resolution of CSF leaks. Although the use of autologous fibrin glue seems to be safe, easy, and effective, further investigations are strongly recommended to quantify real advantages and potential limitations. PMID:25984391

  13. Application of rape pod sealants to reduce adverse environmental impacts.

    Science.gov (United States)

    Bauša, Laimis; Steponavičius, Dainius; Jotautienė, Eglė; Kemzūraitė, Aurelija; Zaleckas, Ernestas

    2018-04-01

    Rape (Brassica napus L.) is a major global oilseed crop characterized by its high potential as an alimentary oil and in biodiesel production. The two most popular pod sealants (PS) used to reduce rape pod shattering are products in the pinolene range (di-1-p-menthene) and latex polymer products. Reports on the effective preservation of seed yield by these products are fairly contradictory. With this in mind, an experimental PS (PS4) that contained the active agents acrylic and trisiloxane was developed. Comparative experimental trials of the developed PS4 and three other PS (PS1, PS2 and PS3) containing active agents that are generally used for sealant production were conducted. The studies showed that the static and dynamic surface tension of PS4 was the lowest at the same concentration (2.0 g kg -1 ), consequently demonstrating the lowest spray drift. The chemical substances from PS had not penetrated the rape seeds in any of the PSs. The results indicate that treatment with PS4 exerts a beneficial effect in reducing rape seed yield loss (68-104 kg ha -1 in 2014 and 194-305 kg ha -1 in 2015) compared to other investigated PS. © 2017 Society of Chemical Industry. © 2017 Society of Chemical Industry.

  14. Collector sealants and breathing. Final Report, 25 September 1978-31 December 1979

    Energy Technology Data Exchange (ETDEWEB)

    Mendelsohn, M A; Luck, R M; Yeoman, F A; Navish, Jr, F W

    1980-02-20

    The objectives of this program were: (1) to investigate the pertinent properties of a variety of possible sealants for solar collectors and identify the most promising candidates, and (2) to study the effect of breathing in flat-plate, thermal solar collector units. The study involved two types of sealants, Class PS which includes preformed seals or gaskets and Class SC which includes sealing compounds or caulks. It was the intent of the study to obtain data regarding initial properties of candidate elastomers from manufacturers and from the technical literature and to use those sources to provide data pertaining to endurance of these materials under environmental service conditions. Where necessary, these data were augmented by experimental measurements. Environmental stresses evaluated by these measurements included elevated temperatures, moisture, ultraviolet light, ozone and oxygen, and fungus. The second major area of the work involved a study of the effects of materials used and design on the durability of solar collectors. Factors such as design, fabrication, materials of construction, seals and sealing techniques and absorber plate coatings were observed on actual field units removed from service. Such phenomena as leakage, corrosion and formation of deposits on glazing and absorber plate were noted. An evaluation of the properties of several desiccants was made in order to providemeans to mitigate the deleterious effects of water on collector life. Adsorbents for organic degradation products of sealants were also investigated in order to protect the glazing and absorber plate from deposited coatings. Since adsorbents and desiccants in general tend to take up both water and organic decomposition products, relative affinities of a number of these agents for water and for organic compounds were determined . Results are presented in detail.

  15. Injectible candidate sealants for fetal membrane repair: Bonding and toxicity in vitro

    Science.gov (United States)

    Bilic, Grozdana; Brubaker, Carrie; Messersmith, Phillip B.; Mallik, Ajit S.; Quinn, Thomas M.; Haller, Claudia; Done, Elisa; Gucciardo, Leonardo; Zeisberger, Steffen M.; Zimmermann, Roland; Deprest, Jan; Zisch, Andreas H.

    2010-01-01

    Objective This study was undertaken to test injectible surgical sealants that are biocompatible with fetal membranes, eventually for closure of iatrogenic membrane defects. Study Design Dermabond, Histoacryl, Tissucol fibrin glue, and three types of in situ forming poly(ethylene glycol)-based polymer hydrogels were tested for acute toxicity upon direct contact with fetal membranes for 24h. For determination of elution toxicity, extracts of sealants were incubated on amnion cell cultures for 72h. Bonding and toxicity was assessed through morphological and/or biochemical analysis. Results Extracts of all adhesives were non-toxic for cultured cells. However, only Tissucol and one type of poly(ethylene glycol)-based hydrogel, mussel-mimetic tissue adhesive, showed efficient, non-disruptive, non-toxic bonding to fetal membranes. Mussel-mimetic tissue adhesive applied over membrane defects created with a 3.5 mm trocar accomplished leak-proof closure that withstood membrane stretch in an in vitro model. Conclusion A synthetic hydrogel-type tissue adhesive emerged as potential sealing modality for iatrogenic membrane defects that merits further evaluation in vivo. PMID:20096254

  16. Consumer and health literacy: The need to better design tobacco-cessation product packaging, labels, and inserts.

    Science.gov (United States)

    Weiss, Stephanie M; Smith-Simone, Stephanie Y

    2010-03-01

    Tobacco-cessation product packaging and instruction materials may not be appropriate for some smokers and may contribute to the underuse and misuse of evidence-based treatments. The dual goals of this project are to analyze literacy levels of Food and Drug Administration (FDA)-approved and non-approved tobacco-cessation product packaging, directions, and claims, and to identify and categorize claims found on product packaging. The Campaign for Tobacco Free Kids (CTFK) maintains the Quitting and Reducing Tobacco Use Inventory of Products (QuiTIP) database, which catalogs products marketed and sold to consumers to reduce or quit use of tobacco products. It also includes all medications approved by the FDA for tobacco cessation as well as a sample of non-approved products such as homeopathic, herbal, nutritional, or dietary supplements commonly marketed as either cessation aids or alternative tobacco/nicotine products. This paper assesses the reading levels required to understand product packaging, labeling, and instructions using the Simple Measure of Gobbledygook (SMOG) and identifies claims on the product package labels using standard qualitative methods. Key findings show that the average reading levels needed to understand instructions for both FDA-approved and non-approved cessation products are above the reading levels recommended to ensure maximum comprehension. Improving the packaging and directions of evidence-based tobacco-cessation products so that they are preferably at or below a fifth-grade reading level, along with using consumer-based design principles to develop packaging, may help smokers take advantage of and correctly use products that will greatly increase their chances of successful quitting. 2010 American Journal of Preventive Medicine. Published by Elsevier Inc. All rights reserved.

  17. 40 CFR 63.6000 - How do I conduct tests and procedures for puncture sealant application affected sources?

    Science.gov (United States)

    2010-07-01

    ... Tire Manufacturing Testing and Initial Compliance Requirements for Puncture Sealant Application... balances to demonstrate compliance, if the storage of materials, exhaust, or the wastewater from more than...

  18. Laparoendoscopic single-site myomectomy and the use of fibrin sealant (Tisseel

    Directory of Open Access Journals (Sweden)

    Angelito Magno

    2015-11-01

    Full Text Available Myomectomy remains the standard surgical treatment for women with uterine myoma, who wish to preserve their fertility. However, it is often associated with increased blood loss and adhesion formation. Laparoscopic myomectomy has multiple advantages over open myomectomy1. A newer approach, laparoendoscopic single-site surgery, also known as LESS, has been developed and applied in gynecologic field.2 This is a case of a 41-year-old G2P1 patient, with the complaints of irregular menstrual cycles and lower abdominal pain for 6 months. Transvaginal ultrasound showed uterine myoma at the anterior corpus, measuring 6 × 5 cm2. The procedure is started by grasping the bilateral edges of the umbilicus with Allis forceps. A vertical incision, 1.5–2 cm, is made from the superficial skin of the umbilicus to the ventral peritoneum. A wound retractor of appropriate size is inserted and adjusted. A multiple instrument access port (LagisEndosurgical, Taichung, Taiwan is placed over the wound retractor (Figure 1. Prior to the procedure, inspection of the pelvic organs is performed to determine the pathology. Vasopressin is injected over the area of the myoma to decrease blood loss. Location of the myoma is then identified. Uterine incision is made on the serosa over the area of the myoma using the monopolar scissors. Using a bipolar instrument LigaSure®, ValleyLab, Inc., Boulder, Colorado, the incision is extended until the myoma is exposed. The myoma is grasped gently using the tenaculum forcep, and dissected bluntly along with it's pseudocapsule using the tip of suction irrigation gear. At the base of the myoma where feeding vessels may be located, coagulation by the advanced bipolar, is performed to prevent bleeding. The specimen is removed through the umbilicus. A sliding knot is made at the tail of one zero monofilament suture to fasten the anchor of the first knot. The uterus is then repaired with a continuous non-locking method. Hemostasis is

  19. Effectiveness of fluoride sealant in the prevention of carious lesions around orthodontic brackets: an OCT evaluation

    Science.gov (United States)

    Pithon, Matheus Melo; Santos, Mariana de Jesus; de Souza, Camilla Andrade; Leão, Jorge César Borges; Braz, Ana Karla Souza; de Araujo, Renato Evangelista; Tanaka, Orlando Motohiro; Oliveira, Dauro Douglas

    2015-01-01

    Abstract Objective: This article aimed to evaluate in vitro the efficiency of Pro Seal fluoride sealant application in the prevention of white spot lesions around orthodontic brackets. Material and Methods: Brackets were bonded to the buccal surface of bovine incisors, and five groups were formed (n = 15) according to the exposure of teeth to oral hygiene substances and the application of enamel sealant: G1 (control), only brushing was performed with 1.450 ppm fluoride; G2 (control) brushing associated with the use of mouthwash with 225 ppm fluoride; G3, only Pro Seal sealant application was performed with 1.000 ppm fluoride; G4 Pro Seal associated with brushing; G5 Pro Seal associated with brushing and mouthwash. Experimental groups alternated between pH cycling and the procedures described. All specimens were kept at a temperature of 37 °C throughout the entire experiment. Both brushing and immersion in solutions were performed within a time interval of one minute, followed by washing in deionized water three times a day for 28 days. Afterwards, an evaluation by Optical Coherence Tomography (OCT) of the spectral type was performed. In each group, a scanning exam of the white spot lesion area (around the sites where brackets were bonded) and depth measurement of carious lesions were performed. Analysis of variance (ANOVA) was applied to determine whether there were significant differences among groups. For post hoc analysis, Tukey test was used. Results: There was statistically significant difference between groups 1 and 2 (p = 0.003), 1 and 3 (p = 0.008), 1 and 4 (p = 0.000) and 1 and 5 (p = 0.000). The group in which only brushing was performed (Group 1) showed deeper enamel lesion. Conclusion: Pro Seal sealant alone or combined with brushing and/or brushing and the use of a mouthwash with fluoride was more effective in protecting enamel, in comparison to brushing alone. PMID:26691968

  20. Microbial viability in preparations packaged for single use.

    Science.gov (United States)

    Obayashi, Akiko; Oie, Shigeharu; Kamiya, Akira

    2003-05-01

    We evaluated microbial viability in preparations packaged for single use only which mandate that residual solution be discarded such as albumin and globulin preparations as blood products, preparations containing albumin (such as urokinase and interferon), fat emulsions, and a preparation containing fat emulsions (propofol). In most preparations, Serratia marcescens and Burkholderia cepacia proliferated rapidly at 30 degrees C. However, in globulin preparations containing 1-2.25% glycine to prevent protein degradation (Gamma-Venin P, Venilon-I, Globulin Injection, and Ahlbulin), no growth of S. marcescens and B. cepacia was detected over 24 h at 30 degrees C. For globulin preparations containing 1-2.25% glycine, the injunction to "Discard residual solution after the package has been used" in the package inserts can be revised to "It is possible to use residual solution within 24 h after the package has been used with storage in a cool place."

  1. Two-year survival of glass ionomer sealanTs placed as parT of ...

    African Journals Online (AJOL)

    2010-09-09

    Sep 9, 2010 ... Two-year survival of glass ionomer sealanTs placed as parT of proximal aTraumaTic. resToraTive ... absTracT. Objective: To evaluate after two years, the survival rate of glass ionomer cement (gic) ... or symptoms of periodontal disease, and clinically the ..... saliva contamination on the bond of dentine resin-.

  2. A Test Method for Monitoring Modulus Changes during Durability Tests on Building Joint Sealants

    Science.gov (United States)

    Christopher C. White; Donald L. Hunston; Kar Tean Tan; Gregory T. Schueneman

    2012-01-01

    The durability of building joint sealants is generally assessed using a descriptive methodology involving visual inspection of exposed specimens for defects. It is widely known that this methodology has inherent limitations, including that the results are qualitative. A new test method is proposed that provides more fundamental and quantitative information about...

  3. Parents' Attitude towards the Use of Fluorides and Fissure Sealants and its Effect on their Children's Oral Health.

    Science.gov (United States)

    Blumer, Sigalit; Ratson, Tal; Peretz, Benjamin; Dagon, Nurit

    To characterize the attitudes of Israeli parents towards caries preventive measures. participating parents completed a 21-item questionnaire on their demographics, dental history, attitudes and satisfaction from fluorides and fissure sealants. One hundred parents (average age 41.62±4.9 years, 85 females) participated. Most of the parents (88% of the mothers and 84% of the fathers) had an academic education. Most of the parents (54%) had a favorable attitude towards the use of fluoridated gels, while only 37% of them had a positive opinion regarding fluoridated water. The satisfaction levels were very high regarding fissure sealants, fluoridated mouth rinses and fluoridated gels (78.1%, 73.6% and 72.5% respectively). The satisfaction from fluoridated water was split almost equally (50.8% were 'pleased' and 49.2% 'not pleased'). The main source for parental oral health knowledge was the dentist (83%). Parents' attitude towards caries preventive measures was significantly correlated to their gender, dental experience, level of education and the number of children in the family. positive attitude towards caries preventive measures was found among parents with higher awareness for preventive oral health measures and among bigger families. Mothers were more positive about fissure sealants than fathers. Mothers with up to 12 years of education tended to have a positive opinion regarding water fluoridation.

  4. Enamel pretreatment with Er:YAG laser: effects on the microleakage of fissure sealant in fluorosed teeth

    Directory of Open Access Journals (Sweden)

    Mahtab Memarpour,

    2014-08-01

    Full Text Available Objectives The purpose of this in vitro study was to evaluate the microleakage and penetration of fissure sealant in permanent molar teeth with fluorosis after pretreatment of the occlusal surface. Materials and Methods A total of 120 third molars with mild dental fluorosis were randomly divided into 6 groups (n = 20. The tooth surfaces were sealed with an unfilled resin fissure sealant (FS material. The experimental groups included: 1 phosphoric acid etching (AE + FS (control; 2 AE + One-Step Plus (OS, Bisco + FS; 3 bur + AE + FS; 4 bur + AE + OS + FS; 5 Er:YAG laser + AE + FS; and 6 Er:YAG laser + AE + OS + FS. After thermocycling, the teeth were immersed in 0.5% fuchsin and sectioned. Proportions of mircoleakage (PM and unfilled area (PUA were measured by digital microscope. Results Overall, there were significant differences among all groups in the PM (p = 0.00. Group 3 showed the greatest PM, and was significantly different from groups 2 to 6 (p < 0.05. Group 6 showed the lowest PM. Pretreatment with Er:YAG with or without adhesive led to less PM than bur pretreatment. There were no significant differences among groups in PUA. Conclusions Conventional acid etching provided a similar degree of occlusal seal in teeth with fluorosis compared to those pretreated with a bur or Er:YAG laser. Pretreatment of pits and fissures with Er:YAG in teeth with fluorosis may be an alternative method before fissure sealant application.

  5. Packaging development needs to support environmental restoration

    International Nuclear Information System (INIS)

    Hummer, J.H.; Kuklinski, J.L.

    1993-01-01

    The U.S. Department of Energy is bringing its facilities into compliance with present environmental protection regulations. At the Hanford Site, this includes cleanup of its vast nuclear and chemical wastes. Cleanup will involve extensive collecting, consolidating, and processing of radioactive and other hazardous wastes. The Hanford Site was established by the Federal government in 1943 to produce plutonium. Natural uranium was fabricated into fuel slugs, inserted into nuclear reactors, and converted into plutonium. The irradiated slugs were then sent through plutonium extraction facilities. Process waste was discharged to the ground, stored on-site, or shipped off-site for disposal. Activities grew to include nine production reactors, five coal-fired power plants, nuclear fuel fabrication, other support facilities including underground waste storage tanks, and numerous chemical and waste processing plants. Cleanup activities will require extensive transport of radioactive and other hazardous materials. Packaging developments and research are required in the following areas to enhance environmental cleanup; (1) Packaging for Large Contaminated and Activated Components. (2) Bulk Packaging for Contaminated Solids. (3) Bulk Packaging for Contaminated Liquids. (4) Environmental Samples. (J.P.N.)

  6. A Systematic Approach to the Study of Accelerated weathering of Building Joint Sealants

    Science.gov (United States)

    Christopher C. White; Donald L. Hunston; Kar Tean Tan; James J. Filliben; Adam L. Pintar; Greg. Schueneman

    2012-01-01

    An accurate service life prediction model is needed for building joint sealants in order to greatly reduce the time to market of a new product and reduce the risk of introducing a poorly performing product into the marketplace. A stepping stone to the success of this effort is the precise control of environmental variables in a laboratory accelerated test apparatus in...

  7. Method of forming a package for MEMS-based fuel cell

    Science.gov (United States)

    Morse, Jeffrey D; Jankowski, Alan F

    2013-05-21

    A MEMS-based fuel cell package and method thereof is disclosed. The fuel cell package comprises seven layers: (1) a sub-package fuel reservoir interface layer, (2) an anode manifold support layer, (3) a fuel/anode manifold and resistive heater layer, (4) a Thick Film Microporous Flow Host Structure layer containing a fuel cell, (5) an air manifold layer, (6) a cathode manifold support structure layer, and (7) a cap. Fuel cell packages with more than one fuel cell are formed by positioning stacks of these layers in series and/or parallel. The fuel cell package materials such as a molded plastic or a ceramic green tape material can be patterned, aligned and stacked to form three dimensional microfluidic channels that provide electrical feedthroughs from various layers which are bonded together and mechanically support a MEMS-based miniature fuel cell. The package incorporates resistive heating elements to control the temperature of the fuel cell stack. The package is fired to form a bond between the layers and one or more microporous flow host structures containing fuel cells are inserted within the Thick Film Microporous Flow Host Structure layer of the package.

  8. A Review of Patents for the Smart Packaging of Meat and Muscle-based Food Products.

    Science.gov (United States)

    Holman, Benjamin; Kerry, Joseph P; Hopkins, David L

    2017-10-31

    Meat packaging once acted primarily as an inert barrier to protect its contents against contamination and this function has shifted. Packaging now includes complementary functions that improve product quality, longevity and customer/retail appeal. The devices and methods applied to achieve these functions may be categorised as smart packaging, which includes intelligent packaging, devised to monitor and communicate packaged content status, and active packaging, to provide passive adjustment of in-pack conditions from its interactions with the packaged meat. Smart packaging examples already available from recent patents include antimicrobial and antioxidant packaging coatings and inserts; sensors or indicators that identify spoilage and freshness; functional engineering customisations; improvements to packaging integrity; leak or tamper detectors; and, environmentally sustainable options. Together, these inventions respond to industry and customer demands for meat packaging and are therefore the focus of this review, in which we discuss their applications and limitations in meat packaging. Copyright© Bentham Science Publishers; For any queries, please email at epub@benthamscience.org.

  9. Resistência ao cisalhamento de um selante associado a componentes de um sistema adesivo dental Shear bond strength of an enamel sealant using components of a dental adhesive system

    Directory of Open Access Journals (Sweden)

    Zilda Maria MUSSOLINO

    1998-10-01

    Full Text Available Cilindros de selante, padronizados, foram unidos ao esmalte das superfícies vestibulares de incisivos bovinos, após serem planificadas e condicionadas, com ácido fosfórico a 37%, durante 30 segundos. Foram utilizados 40 dentes, aleatoriamente divididos em 4 grupos, cujas coroas foram secionadas, de modo a obter-se duas porções, cervical e incisal. No Grupo I, após o condicionamento, aplicou-se o selante Fluroshield; no Grupo II, antes da aplicação do selante, uma camada do "primer" do Probond foi aplicada; no Grupo III, após o "primer", aplicou-se o adesivo do Probond; e no Grupo IV, somente o adesivo foi aplicado antes do selante. Os espécimes foram armazenados em água a 37°C, durante 36 horas, e então submetidos aos ensaios de cisalhamento. A análise estatística revelou significante diminuição na resistência ao cisalhamento, quando o "primer" foi aplicado previamente ao selante, enquanto a resistência ao cisalhamento do selante foi semelhante quando o adesivo do Probond foi aplicado, com ou sem o "primer". A resistência ao cisalhamento do selante ao esmalte é maior no terço incisal que no terço cervical da coroa.Standardized cylinders of sealants were bonded to the flattened labial enamel of bovine incisor teeth that had previously been subjected to 37% phosphoric acid gel for 30 seconds. A total of 40 teeth were tested, randomly divided in four groups of 10 teeth each. In Group I, the sealant Fluroshield was applied after etching; in Group II after etching, the "primer" of Probond was used before the sealant; in Group III after etching, the bond of Probond was used after the "primer"; and in Group IV only the bond was applied before the sealant. Specimens were stored in water at 37°C during 36 hours, before shear testing using a Universal Testing Machine. There was significant reduction in shear bond strength of the sealant when only the "primer" was used previously to the application of the sealant. There were no

  10. A Wrapping Method for Inserting Titanium Micro-Mesh Implants in the Reconstruction of Blowout Fractures

    Directory of Open Access Journals (Sweden)

    Tae Joon Choi

    2016-01-01

    Full Text Available Titanium micro-mesh implants are widely used in orbital wall reconstructions because they have several advantageous characteristics. However, the rough and irregular marginal spurs of the cut edges of the titanium mesh sheet impede the efficacious and minimally traumatic insertion of the implant, because these spurs may catch or hook the orbital soft tissue, skin, or conjunctiva during the insertion procedure. In order to prevent this problem, we developed an easy method of inserting a titanium micro-mesh, in which it is wrapped with the aseptic transparent plastic film that is used to pack surgical instruments or is attached to one side of the inner suture package. Fifty-four patients underwent orbital wall reconstruction using a transconjunctival or transcutaneous approach. The wrapped implant was easily inserted without catching or injuring the orbital soft tissue, skin, or conjunctiva. In most cases, the implant was inserted in one attempt. Postoperative computed tomographic scans showed excellent placement of the titanium micro-mesh and adequate anatomic reconstruction of the orbital walls. This wrapping insertion method may be useful for making the insertion of titanium micro-mesh implants in the reconstruction of orbital wall fractures easier and less traumatic.

  11. Cost-effectiveness, in a randomized trial, of glass-ionomer-based and resin sealant materials after 4 yr

    NARCIS (Netherlands)

    Goldman, A.S.; Chen, X.; Fan, M.; Frencken, J.E.

    2016-01-01

    This study, conducted from a government program perspective, compared the incremental cost-effectiveness of oral health interventions, in particular their delivery to underserved populations in whom dental sealants constitute an important, high-yielding complement to toothbrushing in dental-caries

  12. A case history on long-term effectiveness of clay sealant

    International Nuclear Information System (INIS)

    Lee, C.F.

    1986-01-01

    This report documents a case history in which a cadaver and the associated burial objects were found to be well-preserved after more than 2100 years of burial in Southern China. The preservation was attributed to the presence of a 60-300 cm thick kaolin or white clay layer around the tomb, which acted effectively as a barrier to moisture and air percolation. The degree of preservation in other tombs of similar age in the same area apparently depended on the mineralogy and thickness of the clay sealants used. The implication of this case history to nuclear fuel waste disposal is discussed

  13. Validation of micro-CT against the section method regarding the assessment of marginal leakage of sealants.

    NARCIS (Netherlands)

    Chen, X.; Cuijpers, V.M.J.I.; Fan, M.W.; Frencken, J.E.F.M.

    2012-01-01

    BACKGROUND: The aim of this study was to validate the micro-CT and related software against the section method using the stereomicroscope for marginal leakage assessment along the sealant-enamel interface. METHODS: Pits and fissures of the occlusal surface of 10 teeth were sealed with a

  14. Assessment of the insertion of reprocessed fuel spiked with thorium in a PWR core

    Energy Technology Data Exchange (ETDEWEB)

    Castro, Victor F.; Monteiro, Fabiana B.A.; Pereira, Claubia, E-mail: victorfc@fis.grad.ufmg.br, E-mail: claubia@nuclear.ufmg.br [Universidade Federal de Minas Gerais (UFMG), Belo Horizonte, MG (Brazil). Departamento de Engenharia Nuclear

    2017-07-01

    Reprocessed fuel by UREX+ technique and spiked with thorium was inserted in a PWR core and neutronic parameters have been analyzed. Based on the Final Safety Analysis Report (FSAR) of the Angra-2 reactor, the core was modeled and simulated with SCALE6.0 package. The neutronic data evaluation was carried out by the analysis of the effective and infinite multiplication factors, and the fuel evolution during the burnup. The conversion ratio (CR) was also evaluated. The results show that, when inserting reprocessed fuel spiked with thorium, the insertion of burnable poison rods is not necessary, due to the amount of absorber isotopes present in the fuel. Besides, the conversion ratio obtained was greater than the presented by standard UO{sub 2} fuel, indicating the possibility of extending the burnup. (author)

  15. A Comparative Evaluation of the Effect of Bonding Agent on the Tensile Bond Strength of Two Pit and Fissure Sealants Using Invasive and Non-invasive Techniques: An in-vitro Study.

    Science.gov (United States)

    Singh, Shamsher; Adlakha, Vivek; Babaji, Prashant; Chandna, Preetika; Thomas, Abi M; Chopra, Saroj

    2013-10-01

    Newer technologies and the development of pit and fissure sealants have shifted the treatment philosophy from 'drill and fill' to that of 'seal and heal'. The purpose of this in-vitro study was to evaluate the effects of bonding agents on the tensile bond strengths of two pit and fissure sealants by using invasive and non-invasive techniques. One hundred and twenty bicuspids were collected and teeth were divided into two groups: Group-I (Clinpro) and Group-II (Conseal f) with 60 teeth in each group. For evaluating tensile bond strengths, occlusal surfaces of all the teeth were flattened by reducing buccal and lingual cusps without disturbing fissures. Standardised polyvinyl tube was bonded to occlusal surfaces with respective materials. Sealants were applied, with or without bonding agents, in increments and they were light cured. Tensile bond strengths were determined by using Universal Testing Machine. Data were then statistically analysed by using Student t-test for comparison. A statistically significant difference was found in tensile bond strength in invasive with bonding agent group than in non-invasive with bonding agent group. This study revealed that invasive techniques increase the tensile bond strengths of sealants as compared to non- invasive techniques and that the use of a bonding agent as an intermediate layer between the tooth and fissure sealant is beneficial for increasing the bond strength.

  16. Successful conservative treatment of enterocutaneous fistula with cyanoacrylate surgical sealant: case report.

    Science.gov (United States)

    Musa, N; Aquilino, F; Panzera, P; Martines, G

    2017-01-01

    Enterocutaneous (EC) fistula is an abnormal communication between the gastrointestinal tract and the skin. The majority of EC fistulas result from surgery. Only 15-25% of EC fistulas are spontaneous and they often result from underlying diseases such as Crohn's disease, radiation and chemotherapy. A 62-year old woman who, in 2012, underwent Pylorus-preserving cephalic pancreaticoduodenectomy (PPPD sec. Traverso-Longmire), due to an advanced pancreatic ductal adenocarcinoma (pT3N1M1). After surgery, the patient underwent chemotherapy with folfirinox regimen. In December 2016, as a result of the appearance of metastatic liver lesions and perianastomotic recurrence, the patient underwent second line treatment with Gemcitabine and pab-paclitaxel. After five months from the beginning of this new second line therapy she presented an EC fistula. The fistula of the patient was successfully treated with total parenteral nutrition and with percutaneous injection of cyanoacrylic sealant. The result suggests the advisability of percutaneous injection of sealant devices, such as cyanoacrylate glue; in order to successfully control stable Enterocutaneous fistulas with acceptable morbidity and mortality especially in particular situations, such as, with low output EC fistulas without signs of complications or on patients considered not suitable for surgery, a conservative approach could ensure the control of the fistula. This approach is easy and safe, viable and useful for future trials on the efficacy in conservative treatment of EC fistula.

  17. Motor recovery and synaptic preservation after ventral root avulsion and repair with a fibrin sealant derived from snake venom.

    Directory of Open Access Journals (Sweden)

    Roberta Barbizan

    Full Text Available BACKGROUND: Ventral root avulsion is an experimental model of proximal axonal injury at the central/peripheral nervous system interface that results in paralysis and poor clinical outcome after restorative surgery. Root reimplantation may decrease neuronal degeneration in such cases. We describe the use of a snake venom-derived fibrin sealant during surgical reconnection of avulsed roots at the spinal cord surface. The present work investigates the effects of this fibrin sealant on functional recovery, neuronal survival, synaptic plasticity, and glial reaction in the spinal motoneuron microenvironment after ventral root reimplantation. METHODOLOGY/PRINCIPAL FINDINGS: Female Lewis rats (7 weeks old were subjected to VRA and root replantation. The animals were divided into two groups: 1 avulsion only and 2 replanted roots with fibrin sealant derived from snake venom. Post-surgical motor performance was evaluated using the CatWalk system twice a week for 12 weeks. The rats were sacrificed 12 weeks after surgery, and their lumbar intumescences were processed for motoneuron counting and immunohistochemistry (GFAP, Iba-1 and synaptophysin antisera. Array based qRT-PCR was used to evaluate gene regulation of several neurotrophic factors and receptors as well as inflammatory related molecules. The results indicated that the root reimplantation with fibrin sealant enhanced motor recovery, preserved the synaptic covering of the motoneurons and improved neuronal survival. The replanted group did not show significant changes in microglial response compared to VRA-only. However, the astroglial reaction was significantly reduced in this group. CONCLUSIONS/SIGNIFICANCE: In conclusion, the present data suggest that the repair of avulsed roots with snake venom fibrin glue at the exact point of detachment results in neuroprotection and preservation of the synaptic network at the microenvironment of the lesioned motoneurons. Also such procedure reduced the

  18. Motor Recovery and Synaptic Preservation after Ventral Root Avulsion and Repair with a Fibrin Sealant Derived from Snake Venom

    Science.gov (United States)

    Barbizan, Roberta; Castro, Mateus V.; Rodrigues, Antônio C.; Barraviera, Benedito; Ferreira, Rui S.; Oliveira, Alexandre L. R.

    2013-01-01

    Background Ventral root avulsion is an experimental model of proximal axonal injury at the central/peripheral nervous system interface that results in paralysis and poor clinical outcome after restorative surgery. Root reimplantation may decrease neuronal degeneration in such cases. We describe the use of a snake venom-derived fibrin sealant during surgical reconnection of avulsed roots at the spinal cord surface. The present work investigates the effects of this fibrin sealant on functional recovery, neuronal survival, synaptic plasticity, and glial reaction in the spinal motoneuron microenvironment after ventral root reimplantation. Methodology/Principal Findings Female Lewis rats (7 weeks old) were subjected to VRA and root replantation. The animals were divided into two groups: 1) avulsion only and 2) replanted roots with fibrin sealant derived from snake venom. Post-surgical motor performance was evaluated using the CatWalk system twice a week for 12 weeks. The rats were sacrificed 12 weeks after surgery, and their lumbar intumescences were processed for motoneuron counting and immunohistochemistry (GFAP, Iba-1 and synaptophysin antisera). Array based qRT-PCR was used to evaluate gene regulation of several neurotrophic factors and receptors as well as inflammatory related molecules. The results indicated that the root reimplantation with fibrin sealant enhanced motor recovery, preserved the synaptic covering of the motoneurons and improved neuronal survival. The replanted group did not show significant changes in microglial response compared to VRA-only. However, the astroglial reaction was significantly reduced in this group. Conclusions/Significance In conclusion, the present data suggest that the repair of avulsed roots with snake venom fibrin glue at the exact point of detachment results in neuroprotection and preservation of the synaptic network at the microenvironment of the lesioned motoneurons. Also such procedure reduced the astroglial reaction and

  19. 40 CFR Table 3 to Subpart Xxxx of... - Emission Limits for Puncture Sealant Application Affected Sources

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 12 2010-07-01 2010-07-01 true Emission Limits for Puncture Sealant Application Affected Sources 3 Table 3 to Subpart XXXX of Part 63 Protection of Environment ENVIRONMENTAL... Manufacturing Pt. 63, Subpt. XXXX, Table 3 Table 3 to Subpart XXXX of Part 63—Emission Limits for Puncture...

  20. 40 CFR Table 4 to Subpart Xxxx of... - Operating Limits for Puncture Sealant Application Control Devices

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 12 2010-07-01 2010-07-01 true Operating Limits for Puncture Sealant Application Control Devices 4 Table 4 to Subpart XXXX of Part 63 Protection of Environment ENVIRONMENTAL... Manufacturing Pt. 63, Subpt. XXXX, Table 4 Table 4 to Subpart XXXX of Part 63—Operating Limits for Puncture...

  1. Fissure sealants in caries prevention:a practice-based study using survival analysis

    OpenAIRE

    Leskinen, K. (Kaja)

    2010-01-01

    Abstract The purpose of this study was to analyse the effectiveness and cost of fissure sealant treatment in preventing dental caries in children in a practice-based research network using survival analysis. The survival times of first permanent molars in children were analysed in three countries: in Finland (age cohorts 1970–1972 and 1980–1982), in Sweden (1980–1982) and in Greece (1980–1982), and additionally at two municipal health centres in Finland (age cohorts 1988–1990 in Kemi...

  2. Analysing uncertainty around costs of innovative medical technologies: the case of fibrin sealant (QUIXIL) for total knee replacement.

    NARCIS (Netherlands)

    Steuten, Lotte Maria Gertruda; Vallejo-Torres, Laura; Bastide, Philippe; Buxton, Martin J.

    2009-01-01

    This paper presents a relatively simple cost model comparing the costs of using a commercial fibrin sealant (QUIXIL®) in addition to conventional haemostatic treatment vs. conventional treatment alone in total knee replacement (TKR) surgery, and demonstrates and discusses how one- and two-way

  3. Evaluation of Fibrin Sealants and Tissue Adhesives in Oral Surgery for Patients with Bleeding Disorders

    Directory of Open Access Journals (Sweden)

    Gülsüm Ak

    2012-03-01

    Full Text Available OBJECTIVE: The aim of this study was to evaluate the efficiency of two local haemostatic agents administered together with preoperative dose of replacement therapy for oral surgical procedures in patients with bleeding disorders METHODS: Twenty-one patients were divided into three groups randomly. Patients in Group 1 (n=7 received preoperative replacement therapy with postoperative fibrin sealant application in the surgical site. Patients in Group 2 (n=7 received preoperative replacement therapy with postoperative tissue adhesive application in the surgical site. Patients in Group 3 (n=7 were given total dose of replacement therapy pre- and postoperatively. RESULTS: No postoperative bleeding was observed in 17 patients including five patients in Group 1 (71.42%, six patients in Group 2 (85.71% and six patients in Group 3 (85.71%. Haemorrhagic complication was observed in only four patients among all groups. CONCLUSION: We conclude that utilization of fibrin sealants and tissue adhesives in oral surgery is beneficial due to the lessened amount of factor concentrates used for replacement therapy and the rapid haemostasis at the operation side to perform serial surgical procedures in the same session.

  4. Análise comparativa de embalagens secundárias e bulas de medicamentos contendo Panax ginseng C. A. Meyer A comparative analysis of inner wrapping and package inserts for medicines containing Panax ginseng C. A. Meyer

    Directory of Open Access Journals (Sweden)

    Mariangela Tirico Auricchio

    2007-10-01

    Full Text Available As informações contidas nas bulas e embalagem de medicamentos de diferentes fabricantes contendo Panax ginseng foram analisadas comparativamente com os dados encontrados na literatura científica. Observaram-se bulas longas, com várias informações em relação às indicações de uso, muitas das quais sem comprovação em humanos, e todas foram deficitárias em relação aos .efeitos adversos e interações medicamentosas. Foi observada falta de padronização quanto às posologias, em relação tanto ao extrato seco, quanto ao teor dos ginsenosídeos presentes. Constatou-se a falta de homogeneidade nas informações aos usuários sobre indicações de uso, efeitos adversos e interações medicamentosas entre as oito amostras estudadas.The information provided on package inserts and inner wrapping of eight products containing Panax ginseng from different manufacturers was compared internally and checked against data from the scientific literature. The inserts included extensive text, containing abundant information on indications for use, but no scientific evidence in humans. All the inserts lacked information on potential adverse effects and drug interaction. There was no standardization as to dose regimens, particularly in relation to the dried extract and ginsenoside concentration. The eight inserts thus showed no concern over standardization, indication for usage, or possible side effects and drug interactions.

  5. Dextran/Albumin hydrogel sealant for Dacron(R) vascular prosthesis.

    Science.gov (United States)

    Lisman, Anna; Butruk, Beata; Wasiak, Iga; Ciach, Tomasz

    2014-05-01

    In this paper, the authors describe a novel type of hydrogel coating prepared from the copolymer of human serum albumin and oxidized dextran. The material was designed as a hydrogel sealant for polyester (Dacron®)-based vascular grafts. Dextran was chosen as a coating material due to its anti-thrombogenic properties. Prepared hydrogels were compared with similar, already known biomaterial made from gelatine with the same cross-linking agent. Obtained hydrogels, prepared from various ratios of oxidized dextran/albumin or oxidized dextran/gelatine, showed different cross-linking densities, which caused differences in swelling, degradation rate and mechanical properties. Permeability tests confirmed the complete tightness of the hydrogel-modified prosthesis. Results showed that application of the hydrogel coating provided leakage-free prosthesis and eliminated the need of pre-clotting.

  6. Wafer-Level Packaging Method for RF MEMS Applications Using Pre-Patterned BCB Polymer

    Directory of Open Access Journals (Sweden)

    Zhuhao Gong

    2018-02-01

    Full Text Available A radio-frequency micro-electro-mechanical system (RF MEMS wafer-level packaging (WLP method using pre-patterned benzo-cyclo-butene (BCB polymers with a high-resistivity silicon cap is proposed to achieve high bonding quality and excellent RF performance. In this process, the BCB polymer was pre-defined to form the sealing ring and bonding layer by the spin-coating and patterning of photosensitive BCB before the cavity formation. During anisotropic wet etching of the silicon wafer to generate the housing cavity, the BCB sealing ring was protected by a sputtered Cr/Au (chromium/gold layer. The average measured thickness of the BCB layer was 5.9 μm. In contrast to the conventional methods of spin-coating BCB after fabricating cavities, the pre-patterned BCB method presented BCB bonding layers with better quality on severe topography surfaces in terms of increased uniformity of thickness and better surface flatness. The observation of the bonded layer showed that no void or gap formed on the protruding coplanar waveguide (CPW lines. A shear strength test was experimentally implemented as a function of the BCB widths in the range of 100–400 μm. The average shear strength of the packaged device was higher than 21.58 MPa. A RF MEMS switch was successfully packaged using this process with a negligible impact on the microwave characteristics and a significant improvement in the lifetime from below 10 million to over 1 billion. The measured insertion loss of the packaged RF MEMS switch was 0.779 dB and the insertion loss deterioration caused by the package structure was less than 0.2 dB at 30 GHz.

  7. An empirical study on the relationship of purchasing a chocolate based on its packaging

    Directory of Open Access Journals (Sweden)

    Yasaman Giyahi

    2012-04-01

    Full Text Available Chocolate is one of popular gifts among people in many societies. Packaging of such product plays an important role on marketing this item and the primary question of this survey is to determine the impact of packaging on better introducing a product. The inference statistical tests show that packaging is an important item in selection of chocolate as a gift. Percentage of chocolate is the most important information on packaging and color of packaging is of paramount significance when customers purchase chocolate for individuals with official relationship. In this paper, we present an empirical study to measure the effects of chocolates' packaging on purchasing them. The proposed study of this paper designs a questionnaire and distributes them among different people. The results are analyzed using some non-parametric tests and they are discussed. The preliminary results indicate that the number of purchased packages within a year, cost of purchasing chocolate within a year, type of relationship of recipients of chocolate as gift, gender of recipient of chocolate as gift, age group of recipient of gift, type of store, nationality of chocolate, significance of packaging in various price ranges, type of packaging, insertion of information on package and color of packaging, are important factors influencing people to buy more.

  8. First installation of DT and RPC packages into the CMS iron yoke

    CERN Multimedia

    Jesus Puerta-Pelayo

    2004-01-01

    These pictures illustrate the installation process of muon barrel packages (DT + RPC) into the pockets of the CMS iron yoke at SX5. The chambers are first transported in groups of four from the ISR area (where they are certified and coupled together) to the construction hall in Cessy (neighbouring France), called Point 5 (or SX5). Once there, they pass through a fast high voltage and electronic certification test, before being slid into the insertion cradle. This cradle is attached to the yoke and aligned to the chamber rails, allowing an easy insertion. A rate of 3 chambers per day can be achieved. This set of pictures was taken during the first final insertion round at Point 5, where most chambers for the lower part of YB+2 were installed.

  9. Through-glass copper via using the glass reflow and seedless electroplating processes for wafer-level RF MEMS packaging

    International Nuclear Information System (INIS)

    Lee, Ju-Yong; Lee, Sung-Woo; Lee, Seung-Ki; Park, Jae-Hyoung

    2013-01-01

    We present a novel method for the fabrication of void-free copper-filled through-glass-vias (TGVs), and their application to the wafer-level radio frequency microelectromechanical systems (RF MEMS) packaging scheme. By using the glass reflow process with a patterned silicon mold, a vertical TGV with smooth sidewall and fine pitch could be achieved. Bottom-up void-free filling of the TGV is successfully demonstrated through the seedless copper electroplating process. In addition, the proposed process allows wafer-level packaging with glass cap encapsulation using the anodic bonding process, since the reflowed glass interposer is only formed in the device area surrounded with silicon substrate. A simple coplanar waveguide (CPW) line was employed as the packaged device to evaluate the electrical characteristics and thermo-mechanical reliability of the proposed packaging structure. The fabricated packaging structure showed a low insertion loss of 0.116 dB and a high return loss of 35.537 dB at 20 GHz, which were measured through the whole electrical path, including the CPW line, TGVs and contact pads. An insertion loss lower than 0.1 dB and a return loss higher than 30 dB could be achieved at frequencies of up to 15 GHz, and the resistance of the single copper via was measured to be 36 mΩ. Furthermore, the thermo-mechanical reliability of the proposed packaging structure was also verified through thermal shock and pressure cooker test. (paper)

  10. Applying psychological theories to evidence-based clinical practice: identifying factors predictive of placing preventive fissure sealants.

    Science.gov (United States)

    Bonetti, Debbie; Johnston, Marie; Clarkson, Jan E; Grimshaw, Jeremy; Pitts, Nigel B; Eccles, Martin; Steen, Nick; Thomas, Ruth; Maclennan, Graeme; Glidewell, Liz; Walker, Anne

    2010-04-08

    Psychological models are used to understand and predict behaviour in a wide range of settings, but have not been consistently applied to health professional behaviours, and the contribution of differing theories is not clear. This study explored the usefulness of a range of models to predict an evidence-based behaviour -- the placing of fissure sealants. Measures were collected by postal questionnaire from a random sample of general dental practitioners (GDPs) in Scotland. Outcomes were behavioural simulation (scenario decision-making), and behavioural intention. Predictor variables were from the Theory of Planned Behaviour (TPB), Social Cognitive Theory (SCT), Common Sense Self-regulation Model (CS-SRM), Operant Learning Theory (OLT), Implementation Intention (II), Stage Model, and knowledge (a non-theoretical construct). Multiple regression analysis was used to examine the predictive value of each theoretical model individually. Significant constructs from all theories were then entered into a 'cross theory' stepwise regression analysis to investigate their combined predictive value. Behavioural simulation - theory level variance explained was: TPB 31%; SCT 29%; II 7%; OLT 30%. Neither CS-SRM nor stage explained significant variance. In the cross theory analysis, habit (OLT), timeline acute (CS-SRM), and outcome expectancy (SCT) entered the equation, together explaining 38% of the variance. Behavioural intention - theory level variance explained was: TPB 30%; SCT 24%; OLT 58%, CS-SRM 27%. GDPs in the action stage had significantly higher intention to place fissure sealants. In the cross theory analysis, habit (OLT) and attitude (TPB) entered the equation, together explaining 68% of the variance in intention. The study provides evidence that psychological models can be useful in understanding and predicting clinical behaviour. Taking a theory-based approach enables the creation of a replicable methodology for identifying factors that may predict clinical behaviour

  11. Assessment of Pain and Quality of Life in Lichtenstein Hernia Repair Using a New Monofilament PTFE Mesh: Comparison of Suture vs. Fibrin-Sealant Mesh Fixation.

    Science.gov (United States)

    Fortelny, René H; Petter-Puchner, Alexander H; Redl, Heinz; May, Christopher; Pospischil, Wolfgang; Glaser, Karl

    2014-01-01

    Inguinal hernia repair is one of the most common operations in general surgery. The Lichtenstein tension-free operation has become the gold standard in open inguinal hernia repair. Despite the low recurrence rates, pain and discomfort remain a problem for a large number of patients. The aim of this study was to compare suture fixation vs. fibrin sealing by using a new monofilament PTFE mesh, i.e., the Infinit(®) mesh by W. L. Gore & Associates. This study was designed as a controlled prospective single-center two-cohort study. A total of 38 patients were enrolled and operated in Lichtenstein technique either standard suture mesh fixation or fibrin-sealant mesh fixation were used as described in the TIMELI trial. Primary outcome parameters were postoperative complications with the new mesh (i.e., seroma, infection), pain, and quality of life evaluated by the VAS and the SF-36 questionnaire. Secondary outcome was recurrence assessed by ultrasound and physical examination. Follow-up time was 1 year. Significantly, less postoperative pain was reported in the fibrin-sealant group compared to the suture group at 6 weeks (P = 0.035), 6 months (P = 0.023), and 1 year (P = 0.011) postoperatively. Additionally, trends toward a higher postoperative quality of life, a faster surgical procedure, and a shorter hospital stay were seen in the fibrin-sealant group. Fibrin-sealant mesh fixation in Lichtenstein hernioplasty effectively reduces acute and chronic postoperative pain. Monofilament, macro-porous, knitted PTFE meshes seem to be a practicable alternative to commonly used polypropylene meshes in open inguinal hernia repair.

  12. Assessment of pain and quality of life in Lichtenstein hernia repair using a new monofilament PTFE mesh: comparison of suture vs. fibrin sealant mesh fixation

    Directory of Open Access Journals (Sweden)

    René H Fortelny

    2014-11-01

    Full Text Available Background: Inguinal hernia repair is one of the most common operations in general surgery. The Lichtenstein tension-free operation has become the gold standard in open inguinal hernia repair. Despite the low recurrence rates, pain and discomfort remain a problem for a large number of patients. The aim of this study was to compare suture fixation vs. fibrin sealing by using a new monofilament PTFE mesh, i.e. the Infinit® mesh by W. L. Gore & Associates. Methods: This study was designed as a controlled prospective single-centre two cohort study. A total of 38 patients were enrolled and operated in Lichtenstein technique either standard suture mesh fixation or fibrin sealant mesh fixation were used as described in the TIMELI trial. Primary outcome parameters were postoperative complications with the new mesh (i.e. seroma, infection, pain and quality of life evaluated by the VAS and the SF-36 questionnaire. Secondary outcome was recurrence assessed by ultrasound and physical examination. Follow-up time was 1 year.Results: Significantly less postoperative pain was reported in the fibrin sealant group compared to the suture group at 6 weeks (P=0.035, 6 months (P=0.023 and 1 year (P=0.011 postoperatively. Additionally trends towards a higher postoperative quality of life, a faster surgical procedure and a shorter hospital stay were seen in the fibrin sealant group.Conclusion: Fibrin sealant mesh fixation in Lichtenstein hernioplasty effectively reduces acute and chronic postoperative pain. Monofilament, macro-porous, knitted PTFE meshes seem to be a practicable alternative to commonly used polypropylene meshes in open inguinal hernia repair.

  13. 40 CFR Table 14 to Subpart Xxxx of... - Continuous Compliance With the Emission Limitations for Puncture Sealant Application Affected...

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 12 2010-07-01 2010-07-01 true Continuous Compliance With the Emission Limitations for Puncture Sealant Application Affected Sources 14 Table 14 to Subpart XXXX of Part 63... Hazardous Air Pollutants: Rubber Tire Manufacturing Pt. 63, Subpt. XXXX, Table 14 Table 14 to Subpart XXXX...

  14. Readability of medicinal package leaflets: a systematic review.

    Science.gov (United States)

    Pires, Carla; Vigário, Marina; Cavaco, Afonso

    2015-01-01

    OBJECTIVE To review studies on the readability of package leaflets of medicinal products for human use. METHODS We conducted a systematic literature review between 2008 and 2013 using the keywords "Readability and Package Leaflet" and "Readability and Package Insert" in the academic search engine Biblioteca do Conhecimento Online, comprising different bibliographic resources/databases. The preferred reporting items for systematic reviews and meta-analyses criteria were applied to prepare the draft of the report. Quantitative and qualitative original studies were included. Opinion or review studies not written in English, Portuguese, Italian, French, or Spanish were excluded. RESULTS We identified 202 studies, of which 180 were excluded and 22 were enrolled [two enrolling healthcare professionals, 10 enrolling other type of participants (including patients), three focused on adverse reactions, and 7 descriptive studies]. The package leaflets presented various readability problems, such as complex and difficult to understand texts, small font size, or few illustrations. The main methods to assess the readability of the package leaflet were usability tests or legibility formulae. Limitations with these methods included reduced number of participants; lack of readability formulas specifically validated for specific languages (e.g., Portuguese); and absence of an assessment on patients literacy, health knowledge, cognitive skills, levels of satisfaction, and opinions. CONCLUSIONS Overall, the package leaflets presented various readability problems. In this review, some methodological limitations were identified, including the participation of a limited number of patients and healthcare professionals, the absence of prior assessments of participant literacy, humor or sense of satisfaction, or the predominance of studies not based on role-plays about the use of medicines. These limitations should be avoided in future studies and be considered when interpreting the results.

  15. Influence of surface sealant on the translucency of composite resin: effect of immersion time and immersion media

    Directory of Open Access Journals (Sweden)

    Patrícia Petromilli Nordi Sasso Garcia

    2008-06-01

    Full Text Available This study evaluated the effect of surface sealant on the translucency of composite resin immersed in different solutions. The study involved the following materials: Charisma, Fortify and coffee, Coca-Cola®, tea and artificial saliva as solutions. Sixty-four specimens (n = 8 were manufactured and immersed in artificial saliva at 37 ± 1 °C. Samples were immersed in the solutions for three times a day and re-immersed in artificial saliva until the translucency readings. The measurements were carried out at nine times: T1 - 24 hours after specimen preparation, T2 - 24 hours after immersion in the solutions, T3 - 48 hours and T4 to T9 - 7, 14, 21, 30, 60 and 90 days, respectively, after immersion. The translucency values were measured using a JOUAN device. The results were subjected to ANOVA and Tukey's test at 5%. The surface sealant was not able to protect the composite resin against staining, the coffee showed the strongest staining action, followed by tea and regarding immersion time, a significant alteration was noted in the translucency of composite resin after 21 days.

  16. Autologous fibrin sealant reduces the incidence of prolonged air leak and duration of chest tube drainage after lung volume reduction surgery: a prospective randomized blinded study.

    Science.gov (United States)

    Moser, C; Opitz, I; Zhai, W; Rousson, V; Russi, E W; Weder, W; Lardinois, D

    2008-10-01

    Prolonged air leak is reported in up to 50% of patients after lung volume reduction surgery. The effect of an autologous fibrin sealant on the intensity and duration of air leak and on the time to chest drain removal after lung volume reduction surgery was investigated in a randomized prospective clinical trial. Twenty-five patients underwent bilateral thoracoscopic lung volume reduction surgery. In each patient, an autologous fibrin sealant was applied along the staple lines on one side, whereas no additional measure was taken on the other side. Randomization of treatment was performed at the end of the resection on the first side. Air leak was assessed semiquantitatively by use of a severity score (0 = no leak; 4 = continuous severe leak) by two investigators blinded to the treatment. Mean value of the total severity scores for the first 48 hours postoperative was significantly lower in the treated group (4.7 +/- 7.7) than in the control group (16.0 +/- 10.1) (P drainage were also significantly reduced after application of the sealant (4.5% and 2.8 +/- 1.9 days versus 31.8% and 5.9 +/- 2.9 days) (P = .03 and P drainage.

  17. Method of inserting fuel rod

    International Nuclear Information System (INIS)

    Kamimoto, Shuji; Imoo, Makoto; Tsuchida, Kenji.

    1991-01-01

    The present invention concerns a method of inserting a fuel rod upon automatic assembling, automatic dismantling and reassembling of a fuel assembly in a light water moderated reactor, as well as a device and components used therefor. That is, a fuel rod is inserted reliably to an aimed point of insertion by surrounding the periphery of the fuel rod to be inserted with guide rods, and thereby suppressing the movement of the fuel rod during insertion. Alternatively, a fuel rod is inserted reliably to a point of insertion by inserting guide rods at the periphery of the point of insertion for the fuel rod to be inserted thereby surrounding the point of insertion with the guide rods or fuel rods. By utilizing fuel rods already present in the fuel assembly as the guide rods described above, the fuel rod can be inserted reliably to the point of insertion with no additional devices. Dummy fuel rods are previously inserted in a fuel assembly which are then utilized as the above-mentioned guide rods to accurately insert the fuel rod to the point of insertion. (I.S.)

  18. Blasting agent package

    Energy Technology Data Exchange (ETDEWEB)

    Fox, R.

    1971-03-17

    A protected preassembled package for blasting agents susceptible to desensitization by water consists of, in combination: (1) an inner rigid and self-supporting tube, the upper end of which is suited to be connected, or attached, to the discharge end of a loading hose for a blasting agent and the lower end of which is open; and (2) a flexible tubular liner made of water-resistant film, having a diameter greater than that of the inner tube and a length at least equal to the desired depth of its insertion into the borehole, the liner being sleeved over the length of the inner tube, the upper end of the liner being attached to the inner tube and the lower end of the liner being closed so as to prevent substantial discharge of the explosive mixture therefrom when the latter is pumped into it. (24 claims)

  19. Low-temperature, low-loss zero level packaging techniques for RF applications by using a photopatternable dry film

    International Nuclear Information System (INIS)

    Kim, J; Seok, S; Rolland, N; Rolland, P-A

    2012-01-01

    This paper presents a low-temperature zero-level packaging technique using a dry film type of PerMX polymer for RF devices. Silicon cap packaging with PerMX sealing ring and PerMX cap packaging through multilayer lamination have been implemented. All of the fabrication process has been performed at temperature less than 150 °C. The influence of each packaging cap on the packaged coplanar waveguide was first investigated using the HFSS electromagnetic simulation. The RF measurement results showed that both packaging caps did not have significant influence on the performance of transmission lines. The insertion loss changes before and after packaging were almost negligible up to 30 GHz, and the return losses were better than 20 dB. Also, the deformation of PerMX structures concerning the packaging processes has been studied. For silicon capping, the volumetric compression of PerMX sealing ring by the bonding process has been observed. For PerMX cap packaging, the deflection of the polymer cap has been investigated as a function of sealing ring width for the different cap size. Measured results had good agreement with the ANSYS simulated ones. (paper)

  20. Lattice insertions for POPAE

    International Nuclear Information System (INIS)

    Cho, Y.; Crosbie, E.A.; Diebold, R.; Johnson, D.E.; Ohnuma, S.; Ruggiero, A.G.; Teng, L.C.

    1977-01-01

    Four types of insertions are described for the six 200-m straight sections of POPAE. All have dispersion matched to zero. (1) Injection-ejection insertion--This has proper high-β values and phase advances for horizontal injection and vertical ejection. (2) Phase-adjust insertion--The phase advance in this insertion is adjustable over a range of approximately 100 0 . (3) General-purpose insertion--The β* is adjustable from 2.5. to 200 m and the crossing angle is adjustable from 0 to 11 mrad. (4) High-luminosity insertion--This gives an even lower β + of meter

  1. Applying psychological theories to evidence-based clinical practice: identifying factors predictive of placing preventive fissure sealants

    Directory of Open Access Journals (Sweden)

    Maclennan Graeme

    2010-04-01

    Full Text Available Abstract Background Psychological models are used to understand and predict behaviour in a wide range of settings, but have not been consistently applied to health professional behaviours, and the contribution of differing theories is not clear. This study explored the usefulness of a range of models to predict an evidence-based behaviour -- the placing of fissure sealants. Methods Measures were collected by postal questionnaire from a random sample of general dental practitioners (GDPs in Scotland. Outcomes were behavioural simulation (scenario decision-making, and behavioural intention. Predictor variables were from the Theory of Planned Behaviour (TPB, Social Cognitive Theory (SCT, Common Sense Self-regulation Model (CS-SRM, Operant Learning Theory (OLT, Implementation Intention (II, Stage Model, and knowledge (a non-theoretical construct. Multiple regression analysis was used to examine the predictive value of each theoretical model individually. Significant constructs from all theories were then entered into a 'cross theory' stepwise regression analysis to investigate their combined predictive value Results Behavioural simulation - theory level variance explained was: TPB 31%; SCT 29%; II 7%; OLT 30%. Neither CS-SRM nor stage explained significant variance. In the cross theory analysis, habit (OLT, timeline acute (CS-SRM, and outcome expectancy (SCT entered the equation, together explaining 38% of the variance. Behavioural intention - theory level variance explained was: TPB 30%; SCT 24%; OLT 58%, CS-SRM 27%. GDPs in the action stage had significantly higher intention to place fissure sealants. In the cross theory analysis, habit (OLT and attitude (TPB entered the equation, together explaining 68% of the variance in intention. Summary The study provides evidence that psychological models can be useful in understanding and predicting clinical behaviour. Taking a theory-based approach enables the creation of a replicable methodology for

  2. Detection of occlusal caries with impedance spectroscopy and laser fluorescence before and after placement of fissure sealants: An in vitro study

    DEFF Research Database (Denmark)

    Mortensen, Diana; Ekstrand, Kim; Twetman, Svante

    2016-01-01

    , the DIAGNOdent pen and ICDAS at baseline, after bleaching, etching and placement of a clear fissure sealant. A digital radiograph was exposed at baseline. After the assessments, the actual lesion depth was histologically determined.  Results : Bleaching did not affect the readings but significantly higher ACIS...

  3. Insertion Modeling and Its Applications

    OpenAIRE

    Alexander Letichevsky; Oleksandr Letychevskyi; Vladimir Peschanenko

    2016-01-01

    The paper relates to the theoretical and practical aspects of insertion modeling. Insertion modeling is a theory of agents and environments interaction where an environment is considered as agent with a special insertion function. The main notions of insertion modeling are presented. Insertion Modeling System is described as a tool for development of different kinds of insertion machines. The research and industrial applications of Insertion Modeling System are presented.

  4. Reliability of CGA/LGA/HDI Package Board/Assembly (Final Report)

    Science.gov (United States)

    Ghaffaroam. Reza

    2014-01-01

    Package manufacturers are now offering commercial-off-the-shelf column grid array (COTS CGA) packaging technologies in high-reliability versions. Understanding the process and quality assurance (QA) indicators for reliability are important for low-risk insertion of these advanced electronics packages. The previous reports, released in January of 2012 and January of 2013, presented package test data, assembly information, and reliability evaluation by thermal cycling for CGA packages with 1752, 1517, 1509, and 1272 inputs/outputs (I/Os) and 1-mm pitch. It presented the thermal cycling (-55C either 100C or 125C) test results for up to 200 cycles. This report presents up to 500 thermal cycles with quality assurance and failure analysis evaluation represented by optical photomicrographs, 2D real time X-ray images, dye-and-pry photomicrographs, and optical/scanning electron Microscopy (SEM) cross-sectional images. The report also presents assembly challenge using reflowing by either vapor phase or rework station of CGA and land grid array (LGA) versions of three high I/O packages both ceramic and plastic configuration. A new test vehicle was designed having high density interconnect (HDI) printed circuit board (PCB) with microvia-in-pad to accommodate both LGA packages as well as a large number of fine pitch ball grid arrays (BGAs). The LGAs either were assembled onto HDI PCB as an LGA or were solder paste print and reflow first to form solder dome on pads before assembly. Both plastic BGAs with 1156 I/O and ceramic LGAs were assembled. It also presented the X-ray inspection results as well as failures due to 200 thermal cycles. Lessons learned on assembly of ceramic LGAs are also presented.

  5. COMPARATIVE STUDY OF EARLY POSTPARTUM IUCD INSERTION TO INTERVAL IUCD INSERTION

    Directory of Open Access Journals (Sweden)

    Shibani Devi

    2016-07-01

    Full Text Available INTRODUCTION According to National Family Health Survey-3, Indian women have 13% unmet need for contraception and according to District Level Household & Facility Survey-3, it is 21.3% in the postpartum period. Postpartum intrauterine contraceptive device insertion - both immediately post-placental delivery and somewhat later, but within 48 hours after delivery are options which merit consideration as the woman is likely to have a high motivation for accepting contraception and the healthcare centre provides a convenient setting for insertion of IUCD. AIM Comparison of efficacy and complications of IUCD insertions in post-placental with interval period: 6-month followup. METHOD This perspective study was conducted among 100 women: - 50 women had IUCD inserted within 10 minutes of placental delivery and 50 had insertion more than 6 weeks after delivery. They were followed till 6 months post insertion and were compared regarding early and late complications, continuation rates and expulsion rates. RESULT At the end of six months, we found higher occurrence of lower abdominal pain, heavy menstrual bleeding in case of interval insertion as compared to post-placental insertion which was statistically significant (p value-0.04 & 0.007 respectively. However, the expulsion rates of post-placental IUCD were somewhat elevated (14% compared to interval insertions (2%. Continuation rates at the end of 6 months in both the groups were 82% and 86% respectively which is comparable. CONCLUSION Post-placental IUCD is thus found to be an ideal method to meet the unmet need of postpartum women as it is easily accessible and convenient for both women and their health care providers, is associated with less discomfort and fewer side effects and allow women to obtain safe, long acting, highly effective contraception while still in the health care system.

  6. A Pre- and Post-Evaluation of Integrating Sustainability Curriculum by Inserting Okala Modules into an Interior Design Materials and Methods Course

    Science.gov (United States)

    Schneiderman, Deborah; Freihoefer, Kara

    2012-01-01

    Purpose: The purpose of this paper is to examine the integration of Okala curriculum into Interior Design coursework. Okala, as a teaching package, is utilized extensively in industrial design education. However, this study examines the expansion and insertion of Okala modules in an existing interior design curriculum. The Okala modules included…

  7. Characterization of Fast-Scan Cyclic Voltammetric Electrodes Using Paraffin as an Effective Sealant with In Vitro and In Vivo Applications.

    Science.gov (United States)

    Ramsson, Eric S; Cholger, Daniel; Dionise, Albert; Poirier, Nicholas; Andrus, Avery; Curtiss, Randi

    2015-01-01

    Fast-scan cyclic voltammetry (FSCV) is a powerful technique for measuring sub-second changes in neurotransmitter levels. A great time-limiting factor in the use of FSCV is the production of high-quality recording electrodes; common recording electrodes consist of cylindrical carbon fiber encased in borosilicate glass. When the borosilicate is heated and pulled, the molten glass ideally forms a tight seal around the carbon fiber cylinder. It is often difficult, however, to guarantee a perfect seal between the glass and carbon. Indeed, much of the time spent creating electrodes is in an effort to find a good seal. Even though epoxy resins can be useful in this regard, they are irreversible (seals are permanent), wasteful (epoxy cannot be reused once hardener is added), hazardous (hardeners are often caustic), and require curing. Herein we characterize paraffin as an electrode sealant for FSCV microelectrodes. Paraffin boasts the advantages of near-immediate curing times, simplicity in use, long shelf-life and stable waterproof seals capable of withstanding extended cycling. Borosilicate electrode tips were left intact or broken and dipped in paraffin embedding wax. Excess wax was removed from the carbon surface with xyelenes or by repeated cycling at an extended waveform (-0.4 to 1.4V, 400 V/s, 60 Hz). Then, the waveform was switched to a standard waveform (-0.4 to 1.3V, 400 V/s, 10 Hz) and cycled until stable. Wax-sealing does not inhibit electrode sensitivity, as electrodes detected linear changes in dopamine before and after wax (then xylenes) exposure. Paraffin seals are intact after 11 days of implantation in the mouse, and still capable of measuring transient changes in in vivo dopamine. From this it is clear that paraffin wax is an effective sealant for FSCV electrodes that provides a convenient substitute to epoxy sealants.

  8. Coal-tar pavement sealants might substantially increase children's PAH exposures

    Science.gov (United States)

    Williams, E. Spencer; Mahler, Barbara J.; Van Metre, Peter C.

    2012-01-01

    Dietary ingestion has been identified repeatedly as the primary route of human exposure to polycyclic aromatic hydrocarbons (PAHs), seven of which are classified as probable human carcinogens (B2 PAHs) by the U.S. EPA. Humans are exposed to PAHs through ingestion of cooked and uncooked foods, incidental ingestion of soil and dust, inhalation of ambient air, and absorption through skin. Although PAH sources are ubiquitous in the environment, one recently identified PAH source stands out: Coal-tar-based pavement sealant—a product applied to many parking lots, driveways, and even playgrounds primarily in the central, southern, and eastern U.S.—has PAH concentrations 100–1000 times greater than most other PAH sources. It was reported recently that PAH concentrations in house dust in residences adjacent to parking lots with coal-tar-based sealant were 25 times higher than in residences adjacent to unsealed asphalt parking lots.

  9. Packaging Aspects of Photodetector Modules for 100 Gbit/s Ethernet Applications

    DEFF Research Database (Denmark)

    Jiang, Chenhui; Mekonnen, G.G.; Krozer, Viktor

    2008-01-01

    Packaging is a major problem at millimetre-wave frequencies approaching 100 GHz. In this paper we present that insertion losses in a multi-chip module (MCM) can be less IL ...-backed coplanar waveguides (CBCPWs) with vias is accurately analyzed using 3D electromagnetic (EM) simulation over a wide frequency range. Patch antenna mode resonances are identified as a major origin of resonances in simulated and measured transmission characteristics of the CBCPW with vias. Based on EM...

  10. Humidity data for 9975 shipping packages with cane fiberboard

    Energy Technology Data Exchange (ETDEWEB)

    Daugherty, W. L. [Savannah River Site (SRS), Aiken, SC (United States)

    2016-05-01

    The 9975 surveillance program is developing a technical basis to support extending the storage period of 9975 packages in K-Area Complex beyond the currently approved 15 years. A key element of this effort is developing a better understanding of degradation of the fiberboard assembly under storage conditions. This degradation is influenced greatly by the moisture content of the fiberboard, which is not well characterized on an individual package basis. Direct measurements of humidity and fiberboard moisture content have been made on two test packages with cane fiberboard and varying internal heat levels from 0 up to 19W. With an internal heat load, a temperature gradient in the fiberboard assembly leads to varying relative humidity in the air around the fiberboard. However, the absolute humidity tends to remain approximately constant throughout the package. The moisture content of fiberboard varies under the influence of several phenomena. Changes in local fiberboard temperature (from an internal heat load) can cause fiberboard moisture changes through absorption or evaporation. Fiberboard degradation at elevated temperature will produce water as a byproduct. And the moisture level within the package is constantly seeking equilibrium with that of the surrounding room air, which varies on a daily and seasonal basis. One indicator of the moisture condition within a 9975 package might be obtained by measuring the relative humidity in the upper air space, by inserting a humidity probe through a caplug hole. However, the data indicate that for the higher internal heat loads (15 and 19 watts), a large variation in internal moisture conditions produces little or no variation in the air space relative humidity. Therefore, this approach does not appear to be sensitive to fiberboard moisture variations at the higher heat loads which are of most interest to maintaining fiberboard integrity.

  11. Chest tube insertion

    Science.gov (United States)

    Chest drainage tube insertion; Insertion of tube into chest; Tube thoracostomy; Pericardial drain ... Be careful there are no kinks in your tube. The drainage system should always sit upright and be placed ...

  12. Avaliação clínica de uma resina composta modificada por poliácido, utilizada como selante oclusal, quando aplicada por dentista, THD e graduando Clinical evaluation of a polyacid-modified resin composite, used as an occlusal sealant, when applied by dentist, dental hygienist and undergraduate

    Directory of Open Access Journals (Sweden)

    Roberta Tarkany BASTING

    1999-04-01

    Full Text Available O presente trabalho tem por finalidade comparar as diferenças de retenção de uma resina composta modificada por poliácido (Variglass V.L.C., utilizada como selante oclusal, quando aplicada por dentista, THD e graduando em Odontologia. Foram seladas as superfícies oclusais de 370 primeiros molares permanentes superiores de crianças entre 6 e 8 anos de idade provenientes de escolas públicas do município de Piracicaba. As avaliações clínicas foram realizadas após seis e oito meses da aplicação do selante. Aos seis meses, verificou-se que 78,42% dos selantes clinicamente aceitáveis permaneceram retidos sobre a superfície oclusal. O índice de perdas totais corresponderam a 10,20% do total de selantes aplicados. O melhor índice de retenção total foi obtido quando aplicado por graduando. Aos 12 meses, houve um aumento do número de selantes perdidos (43,79% e conseqüente decréscimo do número de selantes totalmente retidos (18,96%, não havendo diferenças significativas de retenção do selante quando aplicado por dentista, THD e graduando. Nos casos de perdas totais do selante, não se constatou presença de lesão cariosa.The aim of this work is to evaluate the differences of clinical retention of a polyacid-modified resin composite (Variglass V.L.C., used as an occlusal sealant, when applied by dentist, dental hygienist and undergraduate in Dentistry. The occlusal surfaces of 370 superior first molars of children ageing from 6 to 8 years from public schools in Piracicaba, were sealed. The presented data are related to the final evaluation after 6 and 12 months. It was observed that after 6 months, 78.42% of the sealants clinically acceptable, remained on the occlusal surfaces and that the completely lost sealants reached 10.20%. The best results of the sealants retention were obtained when the sealants were applied by an undergraduate. After 12 months, there was an increase of completely lost sealants (43.79% and a decrease of

  13. Layered packaging: A synergistic method of transporting radioactive material

    International Nuclear Information System (INIS)

    Hohmann, G.L.

    1989-01-01

    The DOE certification for a transportation cask used to ship radioactive Krypton 85 from the Idaho Chemical Processing Plant (ICPP) to Oak Ridge National Laboratory (ORNL), was allowed to expire in 1987. The Westinghouse Idaho Nuclear Company (WINCO) was charged by DOE with modifying this cask to meet all current NRC requirements and preparing an updated Safety Analysis Report for Packaging, which would be submitted by DOE to the NRC for certification. However, an urgent need arose for ORNL to receive Krypton 85 which was in storage at the ICPP, which would not allow time to obtain certification of the modified shipping cask. WINCO elected to use a layered shipping configuration in which the gaseous Krypton 85 was placed in the uncertified, modified shipping cask to make use of its shielding and thermal insulation properties. This cask was then inserted into the Model No. 6400 (Super Tiger) packaging using a specially constructed plywood box and polyurethane foam dunnage. Structural evaluations were completed to assure the Super Tiger would provide the necessary impact, puncture, and thermal protection during maximum credible accidents. Analyses were also completed to determine the uncertified Krypton shipping cask would provide the necessary containment and shielding for up to 3.7 E+14 Bq of Krypton 85 when packaged inside the Super Tiger. The resulting reports, based upon this layered packaging concept, were adequate to first obtain DOE certification for several restricted shipments of Krypton 85 and then NRC certification for unrestricted shipments

  14. Experimental insertions

    International Nuclear Information System (INIS)

    Sandweiss, J.; Kycia, T.F.

    1975-01-01

    A discussion is given of the eight identical experimental insertions for the planned ISABELLE storage rings. Four sets of quadrupole doublets are used to match the β functions in the insertions to the values in the cells, and the total free space available at the crossing point is 40 meters. An asymmetric beam energy operation is planned, which will be useful in a number of experiments

  15. A comparison of the effect of short-acting and long-acting cloxacillin-based dry-cow therapy on somatic cell counts after calving in cows also given internal teat sealants.

    Science.gov (United States)

    Whitfield, L K; Laven, R A

    2018-01-01

    To compare, in cows treated with an internal teat sealant, the effect of short-acting and long-acting cloxacillin-based dry-cow therapy on somatic cell counts (SCC) after calving. Cows from a spring-calving, pasture-based dairy farm in the Manawatu-Whanganui region of New Zealand were randomly allocated to receive either a short-acting cloxacillin and ampicillin dry-cow therapy and internal teat sealant (n=291) or a long-acting cloxacillin and ampicillin dry-cow therapy and internal teat sealant (n=288) at the end of lactation. Cows were managed on-farm with routine husbandry procedures through the dry period and following calving. A multivariable logistic regression model was used to determine the association between length of action of dry-cow therapy and the proportion of cows with a SCC >150,000 cells/mL at the first herd test after calving. Age of cow, mean SCC for the preceding season and interval from calving to the first post-calving herd test were all associated with the proportion of cows with an individual SCC >150,000 cells/mL at the first herd test (pcow therapy was not associated with decreased odds of cows having a SCC >150,000 cells/mL at the first herd test compared with treatment with long-acting dry-cow therapy (OR=0.724; 95% CI=0.40-1.30). In this herd, which routinely used internal teat sealants, the use of short-acting cloxacillin-based dry-cow therapy did not result in an increased proportion of cows with elevated SSC post-calving. This was a single farm, single year study but indicates that in this herd, changing from a long-acting to a short-acting antimicrobial may have no impact on the prevalence of subclinical mastitis.

  16. Bond strength of a pit-and-fissure sealant associated to etch-and-rinse and self-etching adhesive systems to saliva-contaminated enamel: individual vs. simultaneous light curing.

    Science.gov (United States)

    Gomes-Silva, Jaciara Miranda; Torres, Carolina Paes; Contente, Marta Maria Martins Giamatei; Oliveira, Maria Angélica Hueb de Menezes; Palma-Dibb, Regina Guenka; Borsatto, Maria Cristina

    2008-01-01

    This study evaluated in vitro the shear bond strength (SBS) of a resin-based pit-and-fissure sealant [Fluroshield (F), Dentsply/Caulk] associated with either an etch-and-rinse [Adper Single Bond 2 (SB), 3M/ESPE] or a self-etching adhesive system [Clearfil S3 Bond (S3), Kuraray Co., Ltd.] to saliva-contaminated enamel, comparing two curing protocols: individual light curing of the adhesive system and the sealant or simultaneous curing of both materials. Mesial and distal enamel surfaces from 45 sound third molars were randomly assigned to 6 groups (n=15), according to the bonding technique: I - F was applied to 37% phosphoric acid etched enamel. The other groups were contaminated with fresh human saliva (0.01 mL; 10 s) after acid etching: II - SB and F were light cured separately; III - SB and F were light cured together; IV - S3 and F were light cured separately; V - S3 and F were light cured simultaneously; VI - F was applied to saliva-contaminated, acid-etched enamel without an intermediate bonding agent layer. SBS was tested to failure in a universal testing machine at 0.5 mm/min. Data were analyzed by one-way ANOVA and Fisher's test (alpha=0.05).The debonded specimens were examined with a stereomicroscope to assess the failure modes. Three representative specimens from each group were observed under scanning electron microscopy for a qualitative analysis. Mean SBS in MPa were: I-12.28 (+/-4.29); II-8.57 (+/-3.19); III-7.97 (+/-2.16); IV-12.56 (+/-3.11); V-11.45 (+/-3.77); and VI-7.47 (+/-1.99). In conclusion, individual or simultaneous curing of the intermediate bonding agent layer and the resin sealant did not seem to affect bond strength to saliva-contaminated enamel. S3/F presented significantly higher SBS than the that of the groups treated with SB etch-and-rinse adhesive system and similar SBS to that of the control group, in which the sealant was applied under ideal dry, noncontaminated conditions.

  17. Safety Analysis Report - Packages, 9965, 9968, 9972-9975 Packages

    International Nuclear Information System (INIS)

    Blanton, P.

    2000-01-01

    This Safety Analysis Report for Packaging (SARP) documents the analysis and testing performed on four type B Packages: the 9972, 9973, 9974, and 9975 packages. Because all four packages have similar designs with very similar performance characteristics, all of them are presented in a single SARP. The performance evaluation presented in this SARP documents the compliance of the 9975 package with the regulatory safety requirements. Evaluations of the 9972, 9973, and 9974 packages support that of the 9975. To avoid confusion arising from the inclusion of four packages in a single document, the text segregates the data for each package in such a way that the reader interested in only one package can progress from Chapter 1 through Chapter 9. The directory at the beginning of each chapter identifies each section that should be read for a given package. Sections marked ''all'' are generic to all packages

  18. White LED with High Package Extraction Efficiency

    International Nuclear Information System (INIS)

    Yi Zheng; Stough, Matthew

    2008-01-01

    in the package may cause a deterioration of encapsulant materials, affecting the performance of both the LED die and phosphor, leading to a decrease in the luminous efficacy over lifetime. Recent studies from research groups at Rensselaer Polytechnic Institute found that, under the condition to obtain a white light, about 40% of the light is transmitted outward of the phosphor layer and 60% of the light is reflected inward.1,2 It is claimed that using scattered photon extraction (SPE) technique, luminous efficacy is increased by 60%. In this project, a transparent/translucent monolithic phosphor was used to replace the powdered phosphor layer. In the normal pcLED package, the powdered phosphor is mixed with silicone either to be deposited on the top of LED die forming a chip level conversion (CLC) white LED or to be casted in the package forming a volume conversion white LED. In the monolithic phosphors there are no phosphor powder/silicone interfaces so it can reduce the light scattering caused by phosphor particles. Additionally, a multi-layer thin film selectively reflecting filter is inserted in the white LED package between the blue LED die and phosphor layer. It will selectively transmit the blue light from the LED die and reflect the phosphor's yellow inward emission outward. The two technologies try to recover backward light to the outward direction in the pcLED package thereby improving the package extraction efficiency.

  19. Bone induction by composites of bioresorbable carriers and demineralized bone in rats: a comparative study of fibrin-collagen paste, fibrin sealant, and polyorthoester with gentamicin

    DEFF Research Database (Denmark)

    Pinholt, E M; Solheim, E; Bang, G

    1992-01-01

    fibrin-collagen paste and fibrin sealant inhibited bone induction and produced a chronic inflammation; part of the fibrin-collagen paste was still present at 4 weeks. Polyorthoester with gentamicin was almost completely absorbed, induced minimal tissue reaction, and did not inhibit osteoinduction....

  20. Insertion device and method for accurate and repeatable target insertion

    Science.gov (United States)

    Gubeli, III, Joseph F.; Shinn, Michelle D.; Bevins, Michael E.; Dillon-Townes, Lawrence; Neil, George R.

    2017-07-04

    The present invention discloses a device and a method for inserting and positioning a target within a free electron laser, particle accelerator, or other such device that generates or utilizes a beam of energy or particles. The system includes a three-point registration mechanism that insures angular and translational accuracy and repeatability of positioning upon multiple insertions within the same structure.

  1. Fissure sealants: in vitro evaluation of abrasion wear and superficial roughness

    Directory of Open Access Journals (Sweden)

    Vanessa Pardi

    2008-06-01

    Full Text Available The aim of this study was to compare the in vitro wear and superficial roughness of four materials (Delton Dyract Flow, Dentsply; Filtek Flow, Vitremer, 3M ESPE used as fissure sealant in 32 extracted human molars divided in four groups (n = 8 after abrasion with toothbrush/dentifrice. Impressions of each occlusal surface were made to analyze wear and circular specimens were prepared to analyze the roughness. Teeth and specimens were mounted in a toothbrushing machine. The replicas were observed using a SEM to determine the superficial wear. Wear: there were no statistically significant differences either between Delton and Filtek Flow or between Dyract Flow and Vitremer. Roughness: there were no statistical differences between Filtek Flow and Dyract Flow, Dyract Flow and Vitremer, Vitremer and Delton., Considering the clinical practice, if caries activity is present the use of Vitremer is suggested not only for its well known fluoride release, but it presented good roughness results.

  2. Facility target insert shielding assessment

    Energy Technology Data Exchange (ETDEWEB)

    Mocko, Michal [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2015-10-06

    Main objective of this report is to assess the basic shielding requirements for the vertical target insert and retrieval port. We used the baseline design for the vertical target insert in our calculations. The insert sits in the 12”-diameter cylindrical shaft extending from the service alley in the top floor of the facility all the way down to the target location. The target retrieval mechanism is a long rod with the target assembly attached and running the entire length of the vertical shaft. The insert also houses the helium cooling supply and return lines each with 2” diameter. In the present study we focused on calculating the neutron and photon dose rate fields on top of the target insert/retrieval mechanism in the service alley. Additionally, we studied a few prototypical configurations of the shielding layers in the vertical insert as well as on the top.

  3. Packaging Solutions : Delivering customer value through Logistical Packaging: A Case Study at Stora Enso Packaging

    OpenAIRE

    Shan, Kun; Julius, Joezer

    2015-01-01

    AbstractBackground;Despite of the significant role of packaging within logistics and supply chain management, packaging is infrequently studied as focal point in supply chain. Most of the previous logistics research studies tend to explain the integration between packaging and logistics through logistical packaging. In very rare cases, the studies mentioned about customer value. Therefore the major disadvantage of these studies is that, they didn’t consider logistical packaging and customer v...

  4. Packaging fluency

    DEFF Research Database (Denmark)

    Mocanu, Ana; Chrysochou, Polymeros; Bogomolova, Svetlana

    2011-01-01

    Research on packaging stresses the need for packaging design to read easily, presuming fast and accurate processing of product-related information. In this paper we define this property of packaging as “packaging fluency”. Based on the existing marketing and cognitive psychology literature on pac...

  5. Feeding tube insertion - gastrostomy

    Science.gov (United States)

    ... this page: //medlineplus.gov/ency/article/002937.htm Feeding tube insertion - gastrostomy To use the sharing features on this page, please enable JavaScript. A gastrostomy feeding tube insertion is the placement of a feeding ...

  6. Microelectronic packaging

    CERN Document Server

    Datta, M; Schultze, J Walter

    2004-01-01

    Microelectronic Packaging analyzes the massive impact of electrochemical technologies on various levels of microelectronic packaging. Traditionally, interconnections within a chip were considered outside the realm of packaging technologies, but this book emphasizes the importance of chip wiring as a key aspect of microelectronic packaging, and focuses on electrochemical processing as an enabler of advanced chip metallization.Divided into five parts, the book begins by outlining the basics of electrochemical processing, defining the microelectronic packaging hierarchy, and emphasizing the impac

  7. Antimicrobial, antioxidant and sensory features of eugenol, carvacrol and trans-anethole in active packaging for organic ready-to-eat iceberg lettuce.

    Science.gov (United States)

    Wieczyńska, Justyna; Cavoski, Ivana

    2018-09-01

    In this study, bio-based emitting sachets containing eugenol (EUG), carvacrol (CAR) and trans-anethole (ANT) were inserted into cellulose (CE) and polypropylene (PP) pillow packages of organic ready-to-eat (RTE) iceberg lettuce to investigate their functional features. EUG, CAR and ANT sachets in CE; and CAR in PP packages showed antimicrobial activities against coliforms (Δlog CFU g -1 of -1.38, -0.91, -0.93 and -0.93, respectively). EUG and ANT sachets in both packages reduced discoloration (ΔE of 9.5, 1.8, 9.4 and 5.6, respectively). ANT in both, and EUG only in PP packages induced biosynthesis of caffeoyl derivatives (C a T A , D i C a T A , D i C a Q A ), total phenolics and antioxidant activity (FRAP). Also, ANT and EUG in both packages improved overall freshness and odor. Principal component analysis separated ANT and EUG from CAR in both packages. The Pearson correlation confirmed that overall quality improvements were more pronounced by ANT inside the packages in comparison to EUG and CAR. Copyright © 2018 Elsevier Ltd. All rights reserved.

  8. Implications for high-precision dose radiation therapy planning or limited surgical resection after percutaneous computed tomography-guided lung nodule biopsy using a tract sealant

    Directory of Open Access Journals (Sweden)

    Patricia M. de Groot, MD

    2018-04-01

    Full Text Available Purpose: Precision radiation therapy such as stereotactic body radiation therapy and limited resection are being used more frequently to treat intrathoracic malignancies. Effective local control requires precise radiation target delineation or complete resection. Lung biopsy tracts (LBT on computed tomography (CT scans after the use of tract sealants can mimic malignant tract seeding (MTS and it is unclear whether these LBTs should be included in the calculated tumor volume or resected. This study evaluates the incidence, appearance, evolution, and malignant seeding of LBTs. Methods and materials: A total of 406 lung biopsies were performed in oncology patients using a tract sealant over 19 months. Of these patients, 326 had follow-up CT scans and were included in the study group. Four thoracic radiologists retrospectively analyzed the imaging, and a pathologist examined 10 resected LBTs. Results: A total of 234 of 326 biopsies (72%, including primary lung cancer [n = 98]; metastases [n = 81]; benign [n = 50]; and nondiagnostic [n = 5] showed an LBT on CT. LBTs were identified on imaging 0 to 3 months after biopsy. LBTs were typically straight or serpiginous with a thickness of 2 to 5 mm. Most LBTs were unchanged (92% or decreased (6.3% over time. An increase in LBT thickness/nodularity that was suspicious for MTS occurred in 4 of 234 biopsies (1.7%. MTS only occurred after biopsy of metastases from extrathoracic malignancies, and none occurred in patients with lung cancer. Conclusions: LBTs are common on CT after lung biopsy using a tract sealant. MTS is uncommon and only occurred in patients with extrathoracic malignancies. No MTS was found in patients with primary lung cancer. Accordingly, potential alteration in planned therapy should be considered only in patients with LBTs and extrathoracic malignancies being considered for stereotactic body radiation therapy or wedge resection.

  9. The Packaging Handbook -- A guide to package design

    International Nuclear Information System (INIS)

    Shappert, L.B.

    1995-01-01

    The Packaging Handbook is a compilation of 14 technical chapters and five appendices that address the life cycle of a packaging which is intended to transport radioactive material by any transport mode in normal commerce. Although many topics are discussed in depth, this document focuses on the design aspects of a packaging. The Handbook, which is being prepared under the direction of the US Department of Energy, is intended to provide a wealth of technical guidance that will give designers a better understanding of the regulatory approval process, preferences of regulators in specific aspects of packaging design, and the types of analyses that should be seriously considered when developing the packaging design. Even though the Handbook is concerned with all packagings, most of the emphasis is placed on large packagings that are capable of transporting large radioactive sources that are also fissile (e.g., spent fuel). These are the types of packagings that must address the widest range of technical topics in order to meet domestic and international regulations. Most of the chapters in the Handbook have been drafted and submitted to the Oak Ridge National Laboratory for editing; the majority of these have been edited. This report summarizes the contents

  10. Comparison of conventional Injection Mould Inserts to Additively Manufactured Inserts using Life Cycle Assessment

    DEFF Research Database (Denmark)

    Hofstätter, Thomas; Bey, Niki; Mischkot, Michael

    2016-01-01

    Polymer Additive Manufacturing can be used to produce soft tooling inserts for injection moulding. Compared to conventional tooling, the energy and time consumption during production are significantly lower. As the life time of such inserts is significantly shorter than the life time of traditional...... of their potential environmental impact and yield throughout the development and pilot phase. Insert geometry is particularly advantageous for pilot production and small production sizes. In this research, Life Cycle Assessment is used to compare the environmental impact of soft tooling by Additive Manufacturing...... (using Digital Light Processing) and three traditional methods for the manufacture of inserts (milling of brass, steel, and aluminium) for injection moulds during the pre-production phase....

  11. Use of FloSeal Sealant in the Surgical Management of Tubal Ectopic Pregnancy

    Directory of Open Access Journals (Sweden)

    Mara Clapp

    2013-01-01

    Full Text Available Background. Surgery is sometimes required for the management of tubal ectopic pregnancies. Historically, surgeons used electrosurgery to obtain hemostasis. Topical hemostatic sealants, such as FloSeal, may decrease the reliance on electrosurgery and reduce thermal injury to the tissue. Case. A 33-year-old G1 P0 received methotrexate for a right tubal pregnancy. The patient became symptomatic six days later and underwent a laparoscopic right salpingotomy. After multiple unsuccessful attempts to obtain hemostasis with electrocoagulation, FloSeal was used and hemostasis was obtained. Six weeks later, a hysterosalpingogram (HSG confirmed tubal patency. The patient subsequently had an intrauterine pregnancy. Conclusion. FloSeal helped to achieve hemostasis during a laparoscopic salpingotomy and preserve tubal patency. FloSeal is an effective alternative and adjunct to electrosurgery in the surgical management of tubal pregnancy.

  12. Data Insertion in Bitcoin's Blockchain

    Directory of Open Access Journals (Sweden)

    Andrew Sward

    2018-04-01

    Full Text Available This paper provides the first comprehensive survey of methods for inserting arbitrary data into Bitcoin’s blockchain. Historical methods of data insertion are described, along with lesser-known techniques that are optimized for efficiency. Insertion methods are compared on the basis of efficiency, cost, convenience of data reconstruction, permanence, and potentially negative impact on the Bitcoin ecosystem.

  13. A Comparative study of early postpartum IUCD insertion to interval IUCD insertion at Tertiary Care Centre

    OpenAIRE

    Roopal, Dr.; Bisht, Vandana

    2018-01-01

    Background: A Comparative study of early postpartum IUCD insertion to interval IUCD insertion at Tertiary Care Centre.Methods: This prospective study was conducted among 100 women at tertiary care centre, Haldwani, Nainital. Patients were divided in to two groups. Group A (n=50)-post placental insertion within 10 minutes of delivery of placenta. Group B (n=50)-Interval insertion after 6 weeks of delivery. Both groups were compared in terms of pain abdomen, bleeding, missing thread, expulsion,...

  14. Intracellular Distribution of Capsid-Associated pUL77 of Human Cytomegalovirus and Interactions with Packaging Proteins and pUL93.

    Science.gov (United States)

    Köppen-Rung, Pánja; Dittmer, Alexandra; Bogner, Elke

    2016-07-01

    DNA packaging into procapsids is a common multistep process during viral maturation in herpesviruses. In human cytomegalovirus (HCMV), the proteins involved in this process are terminase subunits pUL56 and pUL89, which are responsible for site-specific cleavage and insertion of the DNA into the procapsid via portal protein pUL104. However, additional viral proteins are required for the DNA packaging process. We have shown previously that the plasmid that encodes capsid-associated pUL77 encodes another potential player during capsid maturation. Pulse-chase experiments revealed that pUL77 is stably expressed during HCMV infection. Time course analysis demonstrated that pUL77 is expressed in the early late part of the infectious cycle. The sequence of pUL77 was analyzed to find nuclear localization sequences (NLSs), revealing monopartite NLSm at the N terminus and bipartite NLSb in the middle of pUL77. The potential NLSs were inserted into plasmid pHM829, which encodes a chimeric protein with β-galactosidase and green fluorescent protein. In contrast to pUL56, neither NLSm nor NLSb was sufficient for nuclear import. Furthermore, we investigated by coimmunoprecipitation whether packaging proteins, as well as pUL93, the homologue protein of herpes simplex virus 1 pUL17, are interaction partners of pUL77. The interactions between pUL77 and packaging proteins, as well as pUL93, were verified. We showed that the capsid-associated pUL77 is another potential player during capsid maturation of HCMV. Protein UL77 (pUL77) is a conserved core protein of HCMV. This study demonstrates for the first time that pUL77 has early-late expression kinetics during the infectious cycle and an intrinsic potential for nuclear translocation. According to its proposed functions in stabilization of the capsid and anchoring of the encapsidated DNA during packaging, interaction with further DNA packaging proteins is required. We identified physical interactions with terminase subunits pUL56 and p

  15. The kinetics of porous insertion electrodes

    Energy Technology Data Exchange (ETDEWEB)

    Atlung, S; West, K [British Columbia Univ., Vancouver (Canada)

    1989-05-01

    The principles of porous electrodes are discussed as well as the discharge of the insertion compound, the working potential, transport in the electrolyte, the time dependence of the electrolyte concentration, and modeling of the porous electrode. The simulation of a TiS2 porous electrode and the composite insertion electrode are considered as well. The influence of electrode thickness and porosity in a typical porous TiS2 electrode is revealed. It is shown that the use of insertion compounds as battery electrodes is limited by the requirement that the inserted ion must be distributed in the interior of the insertion compound particle. 15 refs.

  16. ALS insertion devices

    International Nuclear Information System (INIS)

    Hoyer, E.; Chin, J.; Halbach, K.; Hassenzahl, W.V.; Humphries, D.; Kincaid, B.; Lancaster, H.; Plate, D.

    1990-11-01

    The Advanced Light Source (ALS), the first US third generation synchrotron radiation source, is currently under construction at the Lawrence Berkeley Laboratory. The low-emittance, 1.5 GeV electron storage ring and the insertion devices are specifically designed to produce high brightness beams in the UV to soft X-Ray range. The planned initial complement of insertion devices includes four 4.6 m long undulators, with period lengths of 3.9 cm, 5.0 cm (2) and 8.0 cm, and a 2.9 m long wiggler of 16 cm period length. Undulator design is well advanced and fabrication has begun on the 5.0 cm and 8.0 cm period length undulators. This paper discusses ALS insertion device requirements; general design philosophy; and design of the magnetic structure, support structure/drive systems, control system and vacuum system. 18 refs., 9 figs., 5 tabs

  17. Percutaneous Ureteral stent insertion

    Energy Technology Data Exchange (ETDEWEB)

    Yoon, Yup; Sung, Dong Wook; Choi, Woo Suk; Lee, Dong Ho; Ko, Young Tae; Lee, Sun Wha; Lim, Jae Hoon [Kyung Hee University Hospital, Seoul (Korea, Republic of)

    1990-10-15

    Percutaneous ureteral stent insertion is a treatment of permanent or temporary urinary diversion to maintain continuity and function of the obstructed and injured ureter. We performed 31 cases of percutaneous double pig tall ureteral stent insertion in 21 patients, included 13 patients with malignant ureteral obstruction and eight patients with injured ureter as well as benign inflammatory stricture. Satisfactory resulted was obtained in all patients but one, who need percutaneous nephrostomy on week later for urinary diversion. No significant complication was encountered. The authors concluded that percutaneous ureteral stent insertion, an interventional procedure alternative to urologic retrograde method, is an effective method for urinary diversion.

  18. The effect of biological sealants and adhesive treatments on matrix metalloproteinase expression during renal injury healing.

    Directory of Open Access Journals (Sweden)

    José Miguel Lloris-Carsí

    Full Text Available Renal injuries are relatively common in cases of abdominal trauma. Adhesives and sealants can be used to repair and preserve damaged organs. Using a rat model, this study explores the activity of different matrix metalloproteinases (MMP during the healing of renal injuries treated by two biological adhesives (TachoSil and GelitaSpon and a new synthetic elastic cyanoacrylate (Adhflex.Renal traumatic injuries were experimentally induced in 90 male Wistar rats by a Stiefel Biopsy Punch in the anterior aspect of the left kidney. Animals were divided into five groups: 1, sham non-injured (n = 3; 2, non-treated standard punch injury (n = 6; 3, punch injury treated with TachoSil (n = 27; 4, punch injury treated with GelitaSpon (n = 27; and, 5, punch injury treated with Adhflex (n = 27. Wound healing was evaluated 2, 6, and 18 days after injury by determining the expression of MMPs, and the histopathological evolution of lesions.Histologically, the wound size at 6 days post-injury was larger in Adhflex-treated samples than in the other treatments, but the scarring tissue was similar at 18 days post-injury. Only the MMPs subtypes 1, 2, 8, 9, and 13 were sufficiently expressed to be quantifiable. Both time since injury and treatment type had a significant influence on MMPs expression. Two days after injury, the expression of MMP8 and MMP9 was predominant. MMP2 expression was greater 6 days after injury. The Adhflex-treated group had a significantly higher MMPs expression than the other treatment groups at all healing stages.All three sealant treatments induced almost similar expression of MMPs than untreated animals indicating a physiological healing process. Given that all renal trauma injuries must be considered emergencies, both biological and synthetic adhesives, such as Adhflex, should be considered as a treatment options.

  19. MEMS packaging

    CERN Document Server

    Hsu , Tai-Ran

    2004-01-01

    MEMS Packaging discusses the prevalent practices and enabling techniques in assembly, packaging and testing of microelectromechanical systems (MEMS). The entire spectrum of assembly, packaging and testing of MEMS and microsystems, from essential enabling technologies to applications in key industries of life sciences, telecommunications and aerospace engineering is covered. Other topics included are bonding and sealing of microcomponents, process flow of MEMS and microsystems packaging, automated microassembly, and testing and design for testing.The Institution of Engineering and Technology is

  20. Packaging design criteria for the Hanford Ecorok Packaging

    International Nuclear Information System (INIS)

    Mercado, M.S.

    1996-01-01

    The Hanford Ecorok Packaging (HEP) will be used to ship contaminated water purification filters from K Basins to the Central Waste Complex. This packaging design criteria documents the design of the HEP, its intended use, and the transportation safety criteria it is required to meet. This information will serve as a basis for the safety analysis report for packaging

  1. Packaging microservices

    DEFF Research Database (Denmark)

    Montesi, Fabrizio; Thrane, Dan Sebastian

    2017-01-01

    We describe a first proposal for a new packaging system for microservices based on the Jolie programming language, called the Jolie Package Manager (JPM). Its main features revolve around service interfaces, which make the functionalities that a service provides and depends on explicit. For the f......We describe a first proposal for a new packaging system for microservices based on the Jolie programming language, called the Jolie Package Manager (JPM). Its main features revolve around service interfaces, which make the functionalities that a service provides and depends on explicit...

  2. CRISPR/Cas9 cleavages in budding yeast reveal templated insertions and strand-specific insertion/deletion profiles.

    Science.gov (United States)

    Lemos, Brenda R; Kaplan, Adam C; Bae, Ji Eun; Ferrazzoli, Alexander E; Kuo, James; Anand, Ranjith P; Waterman, David P; Haber, James E

    2018-02-27

    Harnessing CRISPR-Cas9 technology provides an unprecedented ability to modify genomic loci via DNA double-strand break (DSB) induction and repair. We analyzed nonhomologous end-joining (NHEJ) repair induced by Cas9 in budding yeast and found that the orientation of binding of Cas9 and its guide RNA (gRNA) profoundly influences the pattern of insertion/deletions (indels) at the site of cleavage. A common indel created by Cas9 is a 1-bp (+1) insertion that appears to result from Cas9 creating a 1-nt 5' overhang that is filled in by a DNA polymerase and ligated. The origin of +1 insertions was investigated by using two gRNAs with PAM sequences located on opposite DNA strands but designed to cleave the same sequence. These templated +1 insertions are dependent on the X-family DNA polymerase, Pol4. Deleting Pol4 also eliminated +2 and +3 insertions, which are biased toward homonucleotide insertions. Using inverted PAM sequences, we also found significant differences in overall NHEJ efficiency and repair profiles, suggesting that the binding of the Cas9:gRNA complex influences subsequent NHEJ processing. As with events induced by the site-specific HO endonuclease, CRISPR-Cas9-mediated NHEJ repair depends on the Ku heterodimer and DNA ligase 4. Cas9 events are highly dependent on the Mre11-Rad50-Xrs2 complex, independent of Mre11's nuclease activity. Inspection of the outcomes of a large number of Cas9 cleavage events in mammalian cells reveals a similar templated origin of +1 insertions in human cells, but also a significant frequency of similarly templated +2 insertions.

  3. ISABELLE insertion quadrupoles

    International Nuclear Information System (INIS)

    Kaugerts, J.; Polk, I.; Sampson, W.; Dahl, P.F.

    1979-01-01

    Beam focussing and control at the beam intersection regions of ISABELLE is accomplished by a number of superconducting insertion quadrupoles. These magnets differ from the standard ISABELLE quadrupoles in various ways. In particular, the requirements of limited space near the intersections and aperture for beam extraction impose constraints on their configuration. To achieve optimum beam focussing and provide tuning flexibility calls for stronger quadrupole trim windings than those in the standard quadrupoles. The magnetic and mechanical design of the insertion quadrupoles and their associated correction and steering windings to accomplish the above tasks is presented

  4. Effectiveness of audiovisual distraction in behavior modification during dental caries assessment and sealant placement in children with autism spectrum disorder.

    Science.gov (United States)

    Fakhruddin, Kausar Sadia; El Batawi, Hisham Yehia

    2017-01-01

    The aim of this study was to evaluate the effectiveness of audiovisual (AV) distraction in behavior modification during dental caries assessment and sealant placement in children with autism spectrum disorder. This study was conducted on 28 children diagnosed with autism spectrum disorder, aged 6.5-9.8 years. Children underwent one introductory (desensitization) appointment and three treatment sessions. During the introductory session, children had the procedures explained to them, they watched a movie projected on a screen while oral screening and assessment of cooperation level were carried out. In treatment session I, oral examination, charting, and dental x-rays were undertaken, whereas the children watched movies with or without video eyewear. During treatment sessions II/III, dental prophylaxis was carried out on upper and lower jaws in addition to the application of dental sealants on the right upper and lower and the left upper and lower permanent molars, respectively, while the children were distracted by cartoon movies using video eyewear. Changes in pulse oximeter and heart rate were recorded every 5 min. Independent samples t -test was used to assess the significance of changes in pulse and O 2 saturation levels during each visit. International Caries Detection and Assessment System-code 2 was found to be the most prevalent ( n = 58; 52%). A significant difference ( P behavior in the subjects. Video eyewear distraction proved an effective tool in managing children with autism spectrum disorder during noninvasive preventive dental procedures.

  5. PRIDE Surveillance Projects Data Packaging Project, Information Package Specification Version 1.0

    Energy Technology Data Exchange (ETDEWEB)

    Kelleher, D.M.; Shipp, R. L.; Mason, J. D.

    2009-09-28

    This document contains a specification for a standard XML document format called an information package that can be used to store information and the context required to understand and use that information in information management systems and other types of information archives. An information package consists of packaged information, a set of information metadata that describes the packaged information, and an XML signature that protects the packaged information. The information package described in this specification was designed to be used to store Department of Energy (DOE) and National Nuclear Security Administration (NNSA) information and includes the metadata required for that information: a unique package identifier, information marking that conforms to DOE and NNSA requirements, and access control metadata. Information package metadata can also include information search terms, package history, and notes. Packaged information can be text content, binary content, and the contents of files and other containers. A single information package can contain multiple types of information. All content not in a text form compatible with XML must be in a text encoding such as base64. Package information is protected by a digital XML signature that can be used to determine whether the information has changed since it was signed and to identify the source of the information. This specification has been tested but has not been used to create production information packages. The authors expect that gaps and unclear requirements in this specification will be identified as this specification is used to create information packages and as information stored in information packages is used. The authors expect to issue revised versions of this specification as needed to address these issues.

  6. Sequential cooling insert for turbine stator vane

    Science.gov (United States)

    Jones, Russel B

    2017-04-04

    A sequential flow cooling insert for a turbine stator vane of a small gas turbine engine, where the impingement cooling insert is formed as a single piece from a metal additive manufacturing process such as 3D metal printing, and where the insert includes a plurality of rows of radial extending impingement cooling air holes alternating with rows of radial extending return air holes on a pressure side wall, and where the insert includes a plurality of rows of chordwise extending second impingement cooling air holes on a suction side wall. The insert includes alternating rows of radial extending cooling air supply channels and return air channels that form a series of impingement cooling on the pressure side followed by the suction side of the insert.

  7. Fuel insert shuffler

    International Nuclear Information System (INIS)

    Naser, J.; Colley, R.; Gaiser, J.; Brookmire, T.; Engle, S.

    1987-01-01

    The potential for the use of expert systems in the nuclear power industry is widely recognized. The benefits of such systems include consistency of reasoning during off-normal situations when humans are under great stress, the reduction of time required to perform certain functions and the retention of human expertise in performing specialized functions. As the potential benefits are more and more demonstrated and realized, the development of expert systems becomes a necessary part of the nuclear power industry. The development of the fuel insert shuffle expert system is used as a case study. In fact, it shows that the potential benefits are realizable. Currently, the development of the insert shuffle plan requires three to four man-weeks of effort. Further modifications to this plan are sometimes required dur to either changes in the desired core load pattern or damaged fuel assemblies or inserts. These changes generally require two to four man-days of effort and could be stressful if they are critical path items on the outage schedule

  8. In-Package Chemistry Abstraction

    Energy Technology Data Exchange (ETDEWEB)

    P.S. Domski

    2003-07-21

    The work associated with the development of this model report was performed in accordance with the requirements established in ''Technical Work Plan for Waste Form Degradation Modeling, Testing, and Analyses in Support of SR and LA'' (BSC 2002a). The in-package chemistry model and in-package chemistry model abstraction are developed to predict the bulk chemistry inside of a failed waste package and to provide simplified expressions of that chemistry. The purpose of this work is to provide the abstraction model to the Performance Assessment Project and the Waste Form Department for development of geochemical models of the waste package interior. The scope of this model report is to describe the development and validation of the in-package chemistry model and in-package chemistry model abstraction. The in-package chemistry model will consider chemical interactions of water with the waste package materials and the waste form for commercial spent nuclear fuel (CSNF) and codisposed high-level waste glass (HLWG) and N Reactor spent fuel (CDNR). The in-package chemistry model includes two sub-models, the first a water vapor condensation (WVC) model, where water enters a waste package as vapor and forms a film on the waste package components with subsequent film reactions with the waste package materials and waste form--this is a no-flow model, the reacted fluids do not exit the waste package via advection. The second sub-model of the in-package chemistry model is the seepage dripping model (SDM), where water, water that may have seeped into the repository from the surrounding rock, enters a failed waste package and reacts with the waste package components and waste form, and then exits the waste package with no accumulation of reacted water in the waste package. Both of the submodels of the in-package chemistry model are film models in contrast to past in-package chemistry models where all of the waste package pore space was filled with water. The

  9. In-Package Chemistry Abstraction

    International Nuclear Information System (INIS)

    P.S. Domski

    2003-01-01

    The work associated with the development of this model report was performed in accordance with the requirements established in ''Technical Work Plan for Waste Form Degradation Modeling, Testing, and Analyses in Support of SR and LA'' (BSC 2002a). The in-package chemistry model and in-package chemistry model abstraction are developed to predict the bulk chemistry inside of a failed waste package and to provide simplified expressions of that chemistry. The purpose of this work is to provide the abstraction model to the Performance Assessment Project and the Waste Form Department for development of geochemical models of the waste package interior. The scope of this model report is to describe the development and validation of the in-package chemistry model and in-package chemistry model abstraction. The in-package chemistry model will consider chemical interactions of water with the waste package materials and the waste form for commercial spent nuclear fuel (CSNF) and codisposed high-level waste glass (HLWG) and N Reactor spent fuel (CDNR). The in-package chemistry model includes two sub-models, the first a water vapor condensation (WVC) model, where water enters a waste package as vapor and forms a film on the waste package components with subsequent film reactions with the waste package materials and waste form--this is a no-flow model, the reacted fluids do not exit the waste package via advection. The second sub-model of the in-package chemistry model is the seepage dripping model (SDM), where water, water that may have seeped into the repository from the surrounding rock, enters a failed waste package and reacts with the waste package components and waste form, and then exits the waste package with no accumulation of reacted water in the waste package. Both of the submodels of the in-package chemistry model are film models in contrast to past in-package chemistry models where all of the waste package pore space was filled with water. The current in-package

  10. Advancements in meat packaging.

    Science.gov (United States)

    McMillin, Kenneth W

    2017-10-01

    Packaging of meat provides the same or similar benefits for raw chilled and processed meats as other types of food packaging. Although air-permeable packaging is most prevalent for raw chilled red meat, vacuum and modified atmosphere packaging offer longer shelf life. The major advancements in meat packaging have been in the widely used plastic polymers while biobased materials and their integration into composite packaging are receiving much attention for functionality and sustainability. At this time, active and intelligent packaging are not widely used for antioxidant, antimicrobial, and other functions to stabilize and enhance meat properties although many options are being developed and investigated. The advances being made in nanotechnology will be incorporated into food packaging and presumably into meat packaging when appropriate and useful. Intelligent packaging using sensors for transmission of desired information and prompting of subsequent changes in packaging materials, environments or the products to maintain safety and quality are still in developmental stages. Copyright © 2017 Elsevier Ltd. All rights reserved.

  11. Color in packaging design : Case: ZheJiang JinSheng packaging Co,Ltd

    OpenAIRE

    Hu, Cuicui

    2010-01-01

    Color occupies an important position in packaging design, with the improvement of living standard, the higher requirement of color design in packaging. The aim of this thesis was to discuss key issues concerning aesthetics of packaging design. Topics will include an overview of the packaging design, the influence factor of packaging design, and introduce the aesthetics from packaging aspect. This thesis will also identify common problems of the production process, and list the phases of ho...

  12. Packaging for Sustainability

    CERN Document Server

    Lewis, Helen; Fitzpatrick, Leanne

    2012-01-01

    The packaging industry is under pressure from regulators, customers and other stakeholders to improve packaging’s sustainability by reducing its environmental and societal impacts. This is a considerable challenge because of the complex interactions between products and their packaging, and the many roles that packaging plays in the supply chain. Packaging for Sustainability is a concise and readable handbook for practitioners who are trying to implement sustainability strategies for packaging. Industry case studies are used throughout the book to illustrate possible applications and scenarios. Packaging for Sustainability draws on the expertise of researchers and industry practitioners to provide information on business benefits, environmental issues and priorities, environmental evaluation tools, design for environment, marketing strategies, and challenges for the future.

  13. CDIAC catalog of numeric data packages and computer model packages

    International Nuclear Information System (INIS)

    Boden, T.A.; Stoss, F.W.

    1993-05-01

    The Carbon Dioxide Information Analysis Center acquires, quality-assures, and distributes to the scientific community numeric data packages (NDPs) and computer model packages (CMPs) dealing with topics related to atmospheric trace-gas concentrations and global climate change. These packages include data on historic and present atmospheric CO 2 and CH 4 concentrations, historic and present oceanic CO 2 concentrations, historic weather and climate around the world, sea-level rise, storm occurrences, volcanic dust in the atmosphere, sources of atmospheric CO 2 , plants' response to elevated CO 2 levels, sunspot occurrences, and many other indicators of, contributors to, or components of climate change. This catalog describes the packages presently offered by CDIAC, reviews the processes used by CDIAC to assure the quality of the data contained in these packages, notes the media on which each package is available, describes the documentation that accompanies each package, and provides ordering information. Numeric data are available in the printed NDPs and CMPs, in CD-ROM format, and from an anonymous FTP area via Internet. All CDIAC information products are available at no cost

  14. [Effects of slow twisting needle insertion and tubing needle insertion at Neiguan (PC 6) on cardiovascular function: a comparative study].

    Science.gov (United States)

    Ning, Shaoli; Zhao, Lihua; Xu, Lingjun; Huang, Yu; Pang, Yong; Huang, Dingjian

    2016-01-01

    To compare the effects between slow twisting needle insertion and tubing needle insertion. With cross-over design, 100 healthy young subjects (half male and half female) aged from 19 to 23 years were randomly divided into two groups by random digital table, 50 cases in each one. At the first stage, subjects in the group A were treated with slow twisting needle insertion while, subjects in,the group B were treated with tubing needle insertion. One week later, the procedure of second stage was performed alternately. The needle was inserted into Neiguan (PC 6) with two methods by one acupuncturist. The needle was retained for 5 min before removal. Five min before needle insertion as well as needle withdrawal and 30 min after needle withdrawal, ZXG-E automatic cardiovascular diagnostic apparatus was used to test cardiovascular function. At the tim of needle withdrawal, slow twisting needle insertion could improve effect work of kinetics (EWK), effective blood volume (BV) and reduce elastic expansion coefficient of blood vessel (FEK) and left ventricular spray blood impedance (VER), which was significantly different from tubing needle insertion (all P 0.05). The slow twisting needle insertion is significantly superior to tubing needle insertion on lowering vascular tension and VER, improving EWK and BV.

  15. Chest tube insertion - series (image)

    Science.gov (United States)

    Chest tubes are inserted to drain blood, fluid, or air and allow full expansion of the lungs. The tube is placed in the pleural space. The area where the tube will be inserted is numbed (local anesthesia). The patient may also be sedated. The chest ...

  16. Waste package performance assessment

    International Nuclear Information System (INIS)

    Lester, D.H.

    1981-01-01

    This paper describes work undertaken to assess the life-expectancy and post-failure nuclide release behavior of high-level and waste packages in a geologic repository. The work involved integrating models of individual phenomena (such as heat transfer, corrosion, package deformation, and nuclide transport) and using existing data to make estimates of post-emplacement behavior of waste packages. A package performance assessment code was developed to predict time to package failure in a flooded repository and subsequent transport of nuclides out of the leaking package. The model has been used to evaluate preliminary package designs. The results indicate, that within the limitation of model assumptions and data base, packages lasting a few hundreds of years could be developed. Very long lived packages may be possible but more comprehensive data are needed to confirm this

  17. Edible packaging materials.

    Science.gov (United States)

    Janjarasskul, Theeranun; Krochta, John M

    2010-01-01

    Research groups and the food and pharmaceutical industries recognize edible packaging as a useful alternative or addition to conventional packaging to reduce waste and to create novel applications for improving product stability, quality, safety, variety, and convenience for consumers. Recent studies have explored the ability of biopolymer-based food packaging materials to carry and control-release active compounds. As diverse edible packaging materials derived from various by-products or waste from food industry are being developed, the dry thermoplastic process is advancing rapidly as a feasible commercial edible packaging manufacturing process. The employment of nanocomposite concepts to edible packaging materials promises to improve barrier and mechanical properties and facilitate effective incorporation of bioactive ingredients and other designed functions. In addition to the need for a more fundamental understanding to enable design to desired specifications, edible packaging has to overcome challenges such as regulatory requirements, consumer acceptance, and scaling-up research concepts to commercial applications.

  18. Lithium insertion in nanostructured titanates

    NARCIS (Netherlands)

    Borghols, W.J.H.

    2010-01-01

    Upon nano-sizing of insertion compounds several significant changes in Li-insertion behavior have been observed for sizes below approximately 50 nm. Although the origins of the phenomena are interrelated, the changes can be divided in three main observations. (1) The formation of new phases, leading

  19. Active Packaging Coatings

    Directory of Open Access Journals (Sweden)

    Luis J. Bastarrachea

    2015-11-01

    Full Text Available Active food packaging involves the packaging of foods with materials that provide an enhanced functionality, such as antimicrobial, antioxidant or biocatalytic functions. This can be achieved through the incorporation of active compounds into the matrix of the commonly used packaging materials, or by the application of coatings with the corresponding functionality through surface modification. The latter option offers the advantage of preserving the packaging materials’ bulk properties nearly intact. Herein, different coating technologies like embedding for controlled release, immobilization, layer-by-layer deposition, and photografting are explained and their potential application for active food packaging is explored and discussed.

  20. Test manufacture of a canister insert

    International Nuclear Information System (INIS)

    Raiko, H.

    2004-11-01

    This report describes the insert-manufacturing test of a disposal canister for spent nuclear fuel that was made by Metso Paper Oy, Jyvaeskylae Foundry, in 2003 on contract for Posiva Oy. The test manufacture was a part of the co-operation development programme of encapsulation technology between SKB AB and Posiva Oy. Insert casting was specified according to the current manufacturing specifications of SKB. The canister insert was of BWR-type with integral bottom. This was the first trial manufacture of this type of insert in Finland and, in total, the second test manufacture of insert by Metso Paper. The result fulfilled all the requirements but the material mechanical properties and metallurgical structure of the cast material. The measured tensile strength, ultimate strength and elongation at rupture were lower than specified. The reason for this was revealed in the metallurgical investigation of the cast material. The nodulizing of the graphite was not occurred during the casting process according to the requirements. (orig.)

  1. Safety Analysis Report for packaging (onsite) steel waste package

    International Nuclear Information System (INIS)

    BOEHNKE, W.M.

    2000-01-01

    The steel waste package is used primarily for the shipment of remote-handled radioactive waste from the 324 Building to the 200 Area for interim storage. The steel waste package is authorized for shipment of transuranic isotopes. The maximum allowable radioactive material that is authorized is 500,000 Ci. This exceeds the highway route controlled quantity (3,000 A 2 s) and is a type B packaging

  2. Concepts for stereoselective acrylate insertion

    KAUST Repository

    Neuwald, Boris

    2013-01-23

    Various phosphinesulfonato ligands and the corresponding palladium complexes [{((PaO)PdMeCl)-μ-M}n] ([{( X1-Cl)-μ-M}n], (PaO) = κ2- P,O-Ar2PC6H4SO2O) with symmetric (Ar = 2-MeOC6H4, 2-CF3C6H4, 2,6-(MeO)2C6H3, 2,6-(iPrO)2C 6H3, 2-(2′,6′-(MeO)2C 6H3)C6H4) and asymmetric substituted phosphorus atoms (Ar1 = 2,6-(MeO)2C6H 3, Ar2 = 2′-(2,6-(MeO)2C 6H3)C6H4; Ar1 = 2,6-(MeO)2C6H3, Ar2 = 2-cHexOC 6H4) were synthesized. Analyses of molecular motions and dynamics by variable temperature NMR studies and line shape analysis were performed for the free ligands and the complexes. The highest barriers of ΔGa = 44-64 kJ/mol were assigned to an aryl rotation process, and the flexibility of the ligand framework was found to be a key obstacle to a more effective stereocontrol. An increase of steric bulk at the aryl substituents raises the motional barriers but diminishes insertion rates and regioselectivity. The stereoselectivity of the first and the second methyl acrylate (MA) insertion into the Pd-Me bond of in situ generated complexes X1 was investigated by NMR and DFT methods. The substitution pattern of the ligand clearly affects the first MA insertion, resulting in a stereoselectivity of up to 6:1 for complexes with an asymmetric substituted phosphorus. In the consecutive insertion, the stereoselectivity is diminished in all cases. DFT analysis of the corresponding insertion transition states revealed that a selectivity for the first insertion with asymmetric (P aO) complexes is diminished in the consecutive insertions due to uncooperatively working enantiomorphic and chain end stereocontrol. From these observations, further concepts are developed. © 2012 American Chemical Society.

  3. Method Of Wire Insertion For Electric Machine Stators

    Science.gov (United States)

    Brown, David L; Stabel, Gerald R; Lawrence, Robert Anthony

    2005-02-08

    A method of inserting coils in slots of a stator is provided. The method includes interleaving a first set of first phase windings and a first set of second phase windings on an insertion tool. The method also includes activating the insertion tool to radially insert the first set of first phase windings and the first set of second phase windings in the slots of the stator. In one embodiment, interleaving the first set of first phase windings and the first set of second phase windings on the insertion tool includes forming the first set of first phase windings in first phase openings defined in the insertion tool, and forming the first set of second phase windings in second phase openings defined in the insertion tool.

  4. PRIDE Surveillance Projects Data Packaging Project Information Package Specification Version 1.1

    Energy Technology Data Exchange (ETDEWEB)

    Kelleher, D. M.; Shipp, R. L.; Mason, J. D.

    2010-08-31

    Information Package Specification version 1.1 describes an XML document format called an information package that can be used to store information in information management systems and other information archives. An information package consists of package information, the context required to understand and use that information, package metadata that describes the information, and XML signatures that protect the information. The information package described in this specification was designed to store Department of Energy (DOE) and National Nuclear Security Administration (NNSA) information and includes the metadata required for that information: a unique package identifier, information marking that conforms to DOE and NNSA requirements, and access control metadata. It is an implementation of the Open Archival Information System (OAIS) Reference Model archival information package tailored to meet NNSA information storage requirements and designed to be used in the computing environments at the Y-12 National Security Complex and at other NNSA sites.

  5. Insertion profiles of 4 headless compression screws.

    Science.gov (United States)

    Hart, Adam; Harvey, Edward J; Lefebvre, Louis-Philippe; Barthelat, Francois; Rabiei, Reza; Martineau, Paul A

    2013-09-01

    In practice, the surgeon must rely on screw position (insertion depth) and tactile feedback from the screwdriver (insertion torque) to gauge compression. In this study, we identified the relationship between interfragmentary compression and these 2 factors. The Acutrak Standard, Acutrak Mini, Synthes 3.0, and Herbert-Whipple implants were tested using a polyurethane foam scaphoid model. A specialized testing jig simultaneously measured compression force, insertion torque, and insertion depth at half-screw-turn intervals until failure occurred. The peak compression occurs at an insertion depth of -3.1 mm, -2.8 mm, 0.9 mm, and 1.5 mm for the Acutrak Mini, Acutrak Standard, Herbert-Whipple, and Synthes screws respectively (insertion depth is positive when the screw is proud above the bone and negative when buried). The compression and insertion torque at a depth of -2 mm were found to be 113 ± 18 N and 0.348 ± 0.052 Nm for the Acutrak Standard, 104 ± 15 N and 0.175 ± 0.008 Nm for the Acutrak Mini, 78 ± 9 N and 0.245 ± 0.006 Nm for the Herbert-Whipple, and 67 ± 2N, 0.233 ± 0.010 Nm for the Synthes headless compression screws. All 4 screws generated a sizable amount of compression (> 60 N) over a wide range of insertion depths. The compression at the commonly recommended insertion depth of -2 mm was not significantly different between screws; thus, implant selection should not be based on compression profile alone. Conically shaped screws (Acutrak) generated their peak compression when they were fully buried in the foam whereas the shanked screws (Synthes and Herbert-Whipple) reached peak compression before they were fully inserted. Because insertion torque correlated poorly with compression, surgeons should avoid using tactile judgment of torque as a proxy for compression. Knowledge of the insertion profile may improve our understanding of the implants, provide a better basis for comparing screws, and enable the surgeon to optimize compression. Copyright

  6. HPLOT: the graphics interface package for the HBOOK histogramming package

    International Nuclear Information System (INIS)

    Watkins, H.

    1978-01-01

    The subroutine package HPLOT described in this report, enables the CERN histogramming package HBOOK to produce high-quality pictures by means of high-resolution devices such as plotters. HPLOT can be implemented on any scientific computing system with a Fortran IV compiler and can be interfaced with any graphics package; spectral routines in addition to the basic ones enable users to embellish their histograms. Examples are also given of the use of HPLOT as a graphics package for plotting simple pictures without histograms. (Auth.)

  7. [Evaluation of the effect of one-step self etching adhesives applied in pit and fissure sealing].

    Science.gov (United States)

    Su, Hong-Ru; Xu, Pei-Cheng; Qian, Wen-Hao

    2016-06-01

    To observe the effect of three one-step self etching adhesive systems used in fit and fissure sealant and explore the feasibility of application in caries prevention in school. Seven hundred and twenty completely erupted mandibular first molars in 360 children aged 7 to 9 years old were chosen. The split-mouth design was used to select one side as the experimental group, divided into A1(Easy One Adper), B1(Adper Easy One), and C1(iBond SE).The contra lateral teeth served as A2,B2 and C2 groups (phosphoric acid). The retention and caries status were regularly reviewed .The clinical effect of the two groups was compared using SPSS19.0 software package for Chi - square test. At 3 and 6 months, pit and fissure sealant retention rate in A1 and A2, B1 and B2,C1 and C2 group had no significant difference. At 12 months, sealant retention in A1 and B1 group was significantly lower than A2 and B2 group (P0.05). At 24 months, sealant retention rate in A1, B1 and C1 group was significantly lower than A2, B2 and C2 group (P0.05). The clinical anticariogenic effect of three kinds of one-step etching adhesives and phosphoric acid etching sealant was similar .One-step self etching adhesive system was recommended for pit and fissure sealant to improve the students' oral health. The long-term retention rate of one-step self etching adhesive system was lower than the phosphoric acid method to long term observation is needed.

  8. Package

    Directory of Open Access Journals (Sweden)

    Arsić Zoran

    2013-01-01

    Full Text Available It is duty of the seller to pack the goods in a manner which assures their safe arrival and enables their handling in transit and at the place of destination. The problem of packing is relevant in two main respects. First of all the buyer is in certain circumstances entitled to refuse acceptance of the goods if they are not properly packed. Second, the package is relevant to calculation of price and freight based on weight. In the case of export trade, the package should conform to the legislation in the country of destination. The impact of package on environment is regulated by environment protection regulation of Republic if Serbia.

  9. Packaging-radiation disinfestation relationships

    International Nuclear Information System (INIS)

    Highland, H.A.

    1985-01-01

    Foods that are susceptible to insect infestation can be irradiated to destroy the infestation; however, the food must be kept essentially insect-free until consumed, or it must be disinfested again, perhaps repeatedly. Insect-resistant packages can be used to prevent reinfestation, but there are certain requirements that must be fulfilled before a package can be made insect resistant. These include the use of insect-light construction and packaging materials that resist boring insects. The relative insect resistance of various packages and packaging materials is discussed, as are behavior traits such as egressive boring that enables insects to escape from packages and the ability of insects to climb on various packaging materials. Some successful and unsuccessful attempts to make various types of packages insect resistant are discussed, as are factors that must be considered in the selection or development of insect-resistant packages for radiation disinfested foods. The latter factors include biological and physical environments, length of storage periods, stresses on packages during shipment, types of storage facilities, governmental regulations, health requirements, and others

  10. Initiation and termination of the bacteriophage phi X174 rolling circle DNA replication in vivo: packaging of plasmid single-stranded DNA into bacteriophage phi X174 coats

    NARCIS (Netherlands)

    van der Ende, A.; Teertstra, R.; Weisbeek, P. J.

    1982-01-01

    The bacteriophage phi X174 viral (+) origin when inserted in a plasmid can interact in vivo with the A protein produced by infecting phi X174 phages. A consequence of this interaction is packaging of single-stranded plasmid DNA into preformed phage coats resulting in infective particles (1). This

  11. Packaging Printing Today

    Directory of Open Access Journals (Sweden)

    Stanislav Bolanča

    2015-12-01

    Full Text Available Printing packaging covers today about 50% of all the printing products. Among the printing products there are printing on labels, printing on flexible packaging, printing on folding boxes, printing on the boxes of corrugated board, printing on glass packaging, synthetic and metal ones. The mentioned packaging are printed in flexo printing technique, offset printing technique, intaglio halftone process, silk – screen printing, ink ball printing, digital printing and hybrid printing process. The possibilities of particular printing techniques for optimal production of the determined packaging were studied in the paper. The problem was viewed from the technological and economical aspect. The possible printing quality and the time necessary for the printing realization were taken as key parameters. An important segment of the production and the way of life is alocation value and it had also found its place in this paper. The events in the field of packaging printing in the whole world were analyzed. The trends of technique developments and the printing technology for packaging printing in near future were also discussed.

  12. Packaged die heater

    Science.gov (United States)

    Spielberger, Richard; Ohme, Bruce Walker; Jensen, Ronald J.

    2011-06-21

    A heater for heating packaged die for burn-in and heat testing is described. The heater may be a ceramic-type heater with a metal filament. The heater may be incorporated into the integrated circuit package as an additional ceramic layer of the package, or may be an external heater placed in contact with the package to heat the die. Many different types of integrated circuit packages may be accommodated. The method provides increased energy efficiency for heating the die while reducing temperature stresses on testing equipment. The method allows the use of multiple heaters to heat die to different temperatures. Faulty die may be heated to weaken die attach material to facilitate removal of the die. The heater filament or a separate temperature thermistor located in the package may be used to accurately measure die temperature.

  13. Safety Analysis Report for packaging (onsite) steel waste package

    Energy Technology Data Exchange (ETDEWEB)

    BOEHNKE, W.M.

    2000-07-13

    The steel waste package is used primarily for the shipment of remote-handled radioactive waste from the 324 Building to the 200 Area for interim storage. The steel waste package is authorized for shipment of transuranic isotopes. The maximum allowable radioactive material that is authorized is 500,000 Ci. This exceeds the highway route controlled quantity (3,000 A{sub 2}s) and is a type B packaging.

  14. Packaging Printing Today

    OpenAIRE

    Stanislav Bolanča; Igor Majnarić; Kristijan Golubović

    2015-01-01

    Printing packaging covers today about 50% of all the printing products. Among the printing products there are printing on labels, printing on flexible packaging, printing on folding boxes, printing on the boxes of corrugated board, printing on glass packaging, synthetic and metal ones. The mentioned packaging are printed in flexo printing technique, offset printing technique, intaglio halftone process, silk – screen printing, ink ball printing, digital printing and hybrid printing process. T...

  15. Technological Innovations in the Food Packaging: a case study of adoption of active packaging in coffee roaster companies

    Directory of Open Access Journals (Sweden)

    Mário Otávio Batalha

    2010-12-01

    Full Text Available Most of technological innovations in agro-food systems are created by “supporting industries”, the group where packaging industries are inserted. This article presents the packaging innovations used in food industries, particularly, the active packaging. This paper deals with an adoption case of a degassing one-way valve, describing this innovation and its impacts in two coffee companies. This study can be classified as a documental, qualitative-descriptive and empirical research, using indirect documentation technique and case study analysis. According to this case, the valve made possible the diversification of the company product line and product quality improvement. There were no complications involving an additional cost to the customers. However, it has been observed that this additional cost from technology adoption makes difficult the diffusion of this valve in other similar products.Grande parcela das inovações tecnológicas dos sistemas agroindustriais é gerada pelas “indústrias de apoio”, grupo no qual as indústrias de embalagens se inserem. Esse artigo discute as inovações em embalagens destinadas à indústria de alimentos, em especial as chamadas embalagens ativas. Discute-se o caso de adoção da válvula unidirecional de alívio de gases, descrevendo a inovação e seus impactos em duas indústria processadoras de café nas empresas. A pesquisa desenvolvida é de ordem documental e qualitativo-descritiva de caráter empírica, usando técnica de análise de documentação indireta e estudo de caso . No caso abordado, a válvula possibilitou a diversificação da linha de produtos e o incremento da sua qualidade, não havendo complicações no que se refere ao repasse do custo adicional para o consumidor desse produto. Contudo, verifica-se que esse custo adicional da adoção da tecnologia dificulta a difusão da válvula em produtos similares.

  16. Thermal Management of Power Semiconductor Packages - Matching Cooling Technologies with Packaging Technologies (Presentation)

    Energy Technology Data Exchange (ETDEWEB)

    Bennion, K.; Moreno, G.

    2010-04-27

    Heat removal for power semiconductor devices is critical for robust operation. Because there are different packaging options, different thermal management technologies, and a range of applications, there is a need for a methodology to match cooling technologies and package configurations to target applications. To meet this need, a methodology was developed to compare the sensitivity of cooling technologies on the overall package thermal performance over a range of power semiconductor packaging configurations. The results provide insight into the trade-offs associated with cooling technologies and package configurations. The approach provides a method for comparing new developments in power semiconductor packages and identifying potential thermal control technologies for the package. The results can help users select the appropriate combination of packaging configuration and cooling technology for the desired application.

  17. Acid neutralizing, mechanical and physical properties of pit and fissure sealants containing melt-derived 45S5 bioactive glass.

    Science.gov (United States)

    Yang, Song-Yi; Piao, Yin-Zhu; Kim, Sung-Min; Lee, Yong-Keun; Kim, Kyoung-Nam; Kim, Kwang-Mahn

    2013-12-01

    The aim of this study was to examine the effects of 45S5 bioactive glass (BAG) on the acid neutralizing, mechanical and physical properties of pit and fissure sealants. 45S5BAG (glass (180 ± 30 nm) and added into a resin matrix [Bis-GMA/TEGDMA 50/50 (wt%) containing 1% of DMAEMA/CQ 2:1 (wt%)] with varying filler proportions; 0% 45S5BAG+50% glass (BAG0); 12.5% 45S5BAG+37.5% glass (BAG12.5); 25% 45S5BAG+25% glass (BAG25); 37.5% 45S5BAG+12.5% glass (BAG37.5); and 50% 45S5BAG+0% glass (BAG50). To evaluate the acid neutralizing properties, specimens were immersed in lactic acid solution (pH 4.0). Then, the change in pH and the time required to raise the pH from 4.0 to 5.5 were measured. In addition, flexural strength, water sorption and solubility were analyzed. The acid neutralizing properties of each group exhibited increasing pH values as more 45S5BAG was added, and the time required to raise the pH from 4.0 to 5.5 became shorter as the proportion of 45S5BAG increased (P0.05), except for BAG50. The novel pit and fissure sealants neutralized the acid solution (pH 4.0) and exhibited appropriate mechanical and physical properties. Therefore, these compounds are suitable candidates for caries-inhibiting dental materials. Copyright © 2013 Academy of Dental Materials. Published by Elsevier Ltd. All rights reserved.

  18. Field errors in hybrid insertion devices

    International Nuclear Information System (INIS)

    Schlueter, R.D.

    1995-02-01

    Hybrid magnet theory as applied to the error analyses used in the design of Advanced Light Source (ALS) insertion devices is reviewed. Sources of field errors in hybrid insertion devices are discussed

  19. Field errors in hybrid insertion devices

    Energy Technology Data Exchange (ETDEWEB)

    Schlueter, R.D. [Lawrence Berkeley Lab., CA (United States)

    1995-02-01

    Hybrid magnet theory as applied to the error analyses used in the design of Advanced Light Source (ALS) insertion devices is reviewed. Sources of field errors in hybrid insertion devices are discussed.

  20. NRF TRIGA packaging

    International Nuclear Information System (INIS)

    Clements, M.D.

    1995-11-01

    Training Reactor Isotopes, General Atomics (TRIGA reg-sign) Reactors are in use at four US Department of Energy (DOE) complex facilities and at least 23 university, commercial, or government facilities. The development of the Neutron Radiography Facility (NRF) TRIGA packaging system began in October 1993. The Hanford Site NRF is being shut down and requires an operationally user-friendly transportation and storage packaging system for removal of the TRIGA fuel elements. The NRF TRIGA packaging system is designed to remotely remove the fuel from the reactor and transport the fuel to interim storage (up to 50 years) on the Hanford Site. The packaging system consists of a cask and an overpack. The overpack is used only for transport and is not necessary for storage. Based upon the cask's small size and light weight, small TRIGA reactors will find it versatile for numerous refueling and fuel storage needs. The NRF TRIGA packaging design also provides the basis for developing a certifiable and economical packaging system for other TRIGA reactor facilities. The small size of the NRF TRIGA cask also accommodates placing the cask into a larger certified packaging for offsite transport. The Westinghouse Hanford Company NRF TRIGA packaging, as described herein can serve other DOE sites for their onsite use, and the design can be adapted to serve university reactor facilities, handling a variety of fuel payloads

  1. Insertion mechanics of bioinspired needles into soft tissues.

    Science.gov (United States)

    Sahlabadi, Mohammad; Khodaei, Seyedvahid; Jezler, Kyle; Hutapea, Parsaoran

    2017-12-22

    Most studies to date confirm that any increase in the needle insertion force increases the damage to the tissue. When it comes to brain tissue, even minor damage can cause a long-lasting traumatic brain injury. Thus there is a great demand for innovative minimally invasive needles among the medical community. In our previous studies a novel bioinspired needle design with specially designed barbs was used to perform insertion tests into Polyvinyl chloride (PVC) tissue-mimicking gels, in which it decreased the insertion force by as much as 25%. In this work, bioinspired needles were designed using a CAD software, and were then manufactured using a 3 D printer. The insertion tests into bovine brain and liver were then performed to further investigate the performance of our bioinspired needles in real tissues. Our results show that there was a 10-25% decrease in the insertion force for insertions into bovine brain, and a 35-45% reduction in the insertion force for insertions into bovine liver using the proposed bioinspired needles. The reduction in the insertion force is due to the decrease in the friction force of the bioinspired needle with the bovine tissues, and its results are consistent with our previous results.

  2. Packaging for Food Service

    Science.gov (United States)

    Stilwell, E. J.

    1985-01-01

    Most of the key areas of concern in packaging the three principle food forms for the space station were covered. It can be generally concluded that there are no significant voids in packaging materials availability or in current packaging technology. However, it must also be concluded that the process by which packaging decisions are made for the space station feeding program will be very synergistic. Packaging selection will depend heavily on the preparation mechanics, the preferred presentation and the achievable disposal systems. It will be important that packaging be considered as an integral part of each decision as these systems are developed.

  3. Waste Package Lifting Calculation

    International Nuclear Information System (INIS)

    H. Marr

    2000-01-01

    The objective of this calculation is to evaluate the structural response of the waste package during the horizontal and vertical lifting operations in order to support the waste package lifting feature design. The scope of this calculation includes the evaluation of the 21 PWR UCF (pressurized water reactor uncanistered fuel) waste package, naval waste package, 5 DHLW/DOE SNF (defense high-level waste/Department of Energy spent nuclear fuel)--short waste package, and 44 BWR (boiling water reactor) UCF waste package. Procedure AP-3.12Q, Revision 0, ICN 0, calculations, is used to develop and document this calculation

  4. Certification of packagings: compliance with DOT specification 7A packaging requirements

    International Nuclear Information System (INIS)

    Edling, D.A.

    1976-01-01

    A study was conducted to determine which of the packagings currently listed in CFR 49 Section 173.395 a.1-5, meet the Specification 7A requirements (CFR 49 Section 173.350). According to DOT HM-111 the present listing of various authorized DOT specifications in Section 173.394 and Section 173.395 (Type A containers) of ICC Tariff No. 27 would be deleted with complete reliance being placed on the use of DOT 7A, Type A general packaging specification. Each user of a Specification 7A package would be required to document and maintain on file for one year a written record of his determination of compliance with the DOT Specification 7A performance requirements. All the specification packagings listed in CFR 49 Section 173.395a.1-5 were tested and shown to meet the Specification 7A criteria; however, in many cases qualifications were placed on their use. Forty-nine specification packagings were tested and shown to meet the DOT Specification 7A performance requirements and since there were several styles of some specific packagings, this amounts to greater than 80 packagings. The extensive testing generally indicated a high degree of containment integrity in the packagings tested and the documentation discussed is a valuable tool for shippers of Type A quantities of radioactive materials

  5. Agitation within Mk-42 insert caused by air sparge

    International Nuclear Information System (INIS)

    Ramsey, C.J.

    1991-01-01

    Dissolution of Rocky Flats Pu alloys and Pu metal using a ''nested insert'' configuration (One Well Insert (S-3352) inside the Mk-42 Insert) will require a Nuclear Safety Study, a major assumption of which will be that the annular dissolver is well-mixed. The ''well-mixed'' assumption was theoretically and experimentally supported for alloy dissolution using the Three Well Insert, but the present situation differs significantly. In the former case, the insert was directly exposed to the agitation induced by air sparging; in the case under consideration, the One Well Insert would be shielded by the Mk-42 Insert. In an effort to determine if the ''nested insert'' approach should be pursued, the past studies and technical literature have been surveyed and an attempt made to predict the extent of mixing and bulk circulation for a ''nested insert'' configuration in the presence of air sparging

  6. A wafer-level 3D packaging structure with Benzocyclobutene as a dielectric for multichip module fabrication

    International Nuclear Information System (INIS)

    Geng Fei; Ding Xiaoyun; Xu Gaowei; Luo Le

    2009-01-01

    A new wafer-level 3D packaging structure with Benzocyclobutene (BCB) as interlayer dielectrics (ILDs) for multichip module fabrication is proposed for application in the Ku-band wave. The packaging structure consists of two layers of BCB films and three layers of metallized films, in which the monolithic microwave IC (MMIC), thin film resistors, striplines and microstrip lines are integrated. Wet etched cavities fabricated on the silicon substrate are used for mounting active and passive components. BCB layers cover the components and serve as ILDs for interconnections. Gold bumps are used as electric interconnections between different layers, which eliminates the need to prepare vias by costly dry etching and deposition processes. In order to get high-quality BCB films for the subsequent chemical mechanical planarization (CMP) and multilayer metallization processes, the BCB curing profile is optimized and the roughness of the BCB film after the CMP process is kept lower than 10 nm. The thermal, mechanical and electrical properties of the packaging structure are investigated. The thermal resistance can be controlled below 2 0 C/W. The average shear strength of the gold bumps on the BCB surface is around 70 N/mm 2 . The performances of MMIC and interconnection structure at high frequencies are optimized and tested. The S-parameters curves of the packaged MMIC shift slightly showing perfect transmission character. The insertion loss change after the packaging process is less than 1 dB range at the operating frequency and the return loss is less than -8 dB from 10 to 15 GHz.

  7. Anhydrous Ammonia Training Module. Trainer's Package. Participant's Package.

    Science.gov (United States)

    Beaudin, Bart; And Others

    This document contains a trainer's and a participant's package for teaching employees on site safe handling procedures for working with anhydrous ammonia, especially on farms. The trainer's package includes the following: a description of the module; a competency; objectives; suggested instructional aids; a training outline (or lesson plan) for…

  8. Green Packaging Development. : A way to efficient, effective and more environmental friendly packaging solutions.

    OpenAIRE

    Mian Muhammad, Masoud

    2011-01-01

    Growing pressure on the packaging design to enhance the environmental and logistics performance of a packaging system stresses the packaging designers to search new design strategies that not only fulfill logistics requirements in the supply chain, but also reduce the CO 2emissions during the packaging life cycle. This thesis focuses on the packaging design process and suggests some improvements by considering its logistics performance and CO 2emissions. A Green packaging development model wa...

  9. Reactivity insertion accident analysis

    International Nuclear Information System (INIS)

    Moreira, J.M.L.; Nakata, H.; Yorihaz, H.

    1990-04-01

    The correct prediction of postulated accidents is the fundamental requirement for the reactor licensing procedures. Accident sequences and severity of their consequences depend upon the analysis which rely on analytical tools which must be validated against known experimental results. Present work presents a systematic approach to analyse and estimate the reactivity insertion accident sequences. The methodology is based on the CINETHICA code which solves the point-kinetics/thermohydraulic coupled equations with weighted temperature feedback. Comparison against SPERT experimental results shows good agreement for the step insertion accidents. (author) [pt

  10. IN-PACKAGE CHEMISTRY ABSTRACTION

    Energy Technology Data Exchange (ETDEWEB)

    E. Thomas

    2005-07-14

    This report was developed in accordance with the requirements in ''Technical Work Plan for Postclosure Waste Form Modeling'' (BSC 2005 [DIRS 173246]). The purpose of the in-package chemistry model is to predict the bulk chemistry inside of a breached waste package and to provide simplified expressions of that chemistry as a function of time after breach to Total Systems Performance Assessment for the License Application (TSPA-LA). The scope of this report is to describe the development and validation of the in-package chemistry model. The in-package model is a combination of two models, a batch reactor model, which uses the EQ3/6 geochemistry-modeling tool, and a surface complexation model, which is applied to the results of the batch reactor model. The batch reactor model considers chemical interactions of water with the waste package materials, and the waste form for commercial spent nuclear fuel (CSNF) waste packages and codisposed (CDSP) waste packages containing high-level waste glass (HLWG) and DOE spent fuel. The surface complexation model includes the impact of fluid-surface interactions (i.e., surface complexation) on the resulting fluid composition. The model examines two types of water influx: (1) the condensation of water vapor diffusing into the waste package, and (2) seepage water entering the waste package as a liquid from the drift. (1) Vapor-Influx Case: The condensation of vapor onto the waste package internals is simulated as pure H{sub 2}O and enters at a rate determined by the water vapor pressure for representative temperature and relative humidity conditions. (2) Liquid-Influx Case: The water entering a waste package from the drift is simulated as typical groundwater and enters at a rate determined by the amount of seepage available to flow through openings in a breached waste package.

  11. IN-PACKAGE CHEMISTRY ABSTRACTION

    International Nuclear Information System (INIS)

    E. Thomas

    2005-01-01

    This report was developed in accordance with the requirements in ''Technical Work Plan for Postclosure Waste Form Modeling'' (BSC 2005 [DIRS 173246]). The purpose of the in-package chemistry model is to predict the bulk chemistry inside of a breached waste package and to provide simplified expressions of that chemistry as a function of time after breach to Total Systems Performance Assessment for the License Application (TSPA-LA). The scope of this report is to describe the development and validation of the in-package chemistry model. The in-package model is a combination of two models, a batch reactor model, which uses the EQ3/6 geochemistry-modeling tool, and a surface complexation model, which is applied to the results of the batch reactor model. The batch reactor model considers chemical interactions of water with the waste package materials, and the waste form for commercial spent nuclear fuel (CSNF) waste packages and codisposed (CDSP) waste packages containing high-level waste glass (HLWG) and DOE spent fuel. The surface complexation model includes the impact of fluid-surface interactions (i.e., surface complexation) on the resulting fluid composition. The model examines two types of water influx: (1) the condensation of water vapor diffusing into the waste package, and (2) seepage water entering the waste package as a liquid from the drift. (1) Vapor-Influx Case: The condensation of vapor onto the waste package internals is simulated as pure H 2 O and enters at a rate determined by the water vapor pressure for representative temperature and relative humidity conditions. (2) Liquid-Influx Case: The water entering a waste package from the drift is simulated as typical groundwater and enters at a rate determined by the amount of seepage available to flow through openings in a breached waste package

  12. Wear and superficial roughness of glass ionomer cements used as sealants, after simulated toothbrushing Desgaste e rugosidade superficial de cimentos de ionômero de vidro utilizados como selantes, após escovação simulada

    Directory of Open Access Journals (Sweden)

    Daniela Rios

    2002-12-01

    Full Text Available The purpose of this study was to evaluate, in vitro, the properties (wear and roughness of glass ionomer cements that could influence their indication as pit and fissure sealants. The utilized materials were Fuji Plus, Ketac-Molar and Vitremer (in two different proportions: 1:1 and ¼:1. The resin-based sealant Delton was used as control. By means of an electronic balance (precision of 10-4 g, wear was measured in function of weight loss after simulated toothbrushing. Superficial roughness was determined by means of a surface roughness-measuring apparatus. The results revealed that diluted Vitremer and Fuji Plus were less resistant to toothbrushing abrasion and had the greatest increase in superficial roughness.Although in clinical situations luting or diluted ionomer cements are often utilized as alternatives to resin-based sealants, the resultsof this study revealed that the properties of those cements are worse than those of restorative ionomers, whichpresented results similar to those of the evaluated resin sealant.O presente estudo foi conduzido in vitro com o intuito de constatar as propriedades (desgaste e rugosidade dos CIV, as quais influenciam na sua indicação como material selador de fossas e fissuras. Os materiais empregados foram Fuji Plus, Ketac-Molar e Vitremer (duas proporções: 1:1 e ¼:1. O selante Delton foi controle. A determinação do desgaste foi obtida através da quantidade de massa perdida após a escovação e a rugosidade através da análise quantitativa da superfície. Os resultados mostraram que o Vitremer diluído e o Fuji Plus apresentaram maior grau de desgaste e maior aumento de rugosidade. Apesar de clinicamente se encontrar um maior uso dos ionômeros de vidro cimentantes ou diluídos como forma alternativa para material selador; este trabalho permitiu concluir que estes possuem propriedades bastante inferiores quando comparados aos ionômeros restauradores que, por sua vez, possuem resultados semelhantes

  13. Hazardous materials package performance regulations

    International Nuclear Information System (INIS)

    Russell, N.A.; Glass, R.E.; McClure, J.D.; Finley, N.C.

    1992-01-01

    The hazardous materials (hazmat) packaging development and certification process is currently defined by two different regulatory philosophies, one based on specification packagings and the other based on performance standards. With specification packagings, a packaging is constructed according to an agreed set of design specifications. In contrast, performance standards do not specify the packaging design; they specify performance standards that a packaging design must be able to pass before it can be certified for transport. The packaging can be designed according to individual needs as long as it meets these performance standards. Performance standards have been used nationally and internationally for about 40 years to certify radioactive materials (RAM) packagings. It is reasonable to state that for RAM transport, performance specifications have maintained transport safety. A committee of United Nation's experts recommended the performance standard philosophy as the preferred regulation method for hazmat packaging. Performance standards for hazmat packagings smaller than 118 gallons have been adopted in 49CFR178. Packagings for materials that are classified as toxic-by-inhalation must comply with the performance standards by October 1, 1993, and packagings for all other classes of hazardous materials covered must comply by October 1, 1996. For packages containing bulk (in excess of 188 gallons) quantities of materials that are extremely toxic by inhalation, there currently are no performance requirements. This paper discusses a Hazmat Packaging Performance Evaluation (HPPE) project to look at the subset of bulk packagings that are larger than 2000 gallons. The objectives of this project are the evaluate current hazmat specification packagings and develop supporting documentation for determining performance requirements for packagings in excess of 2000 gallons that transport hazardous materials that have been classified as extremely toxic by inhalation (METBI)

  14. Lithium niobate packaging challenges

    International Nuclear Information System (INIS)

    Murphy, E.J.; Holmes, R.J.; Jander, R.B.; Schelling, A.W.

    1988-01-01

    The use of lithium niobate integrated optic devices outside of the research laboratory is predicated on the development of a sound packaging method. The authors present a discussion of the many issues that face the development of a viable, robust packaging technology. The authors emphasize the interaction of lithium niobate's physical properties with available packaging materials and technologies. The broad range of properties (i.e. electro-optic, piezo-electric, pyro-electric, photorefractive...) that make lithium niobate an interesting material in many device applications also make it a packaging challenge. The package design, materials and packaging technologies must isolate the device from the environment so that lithium niobate's properties do not adversely affect the device performance

  15. Turbine airfoil having near-wall cooling insert

    Science.gov (United States)

    Martin, Jr., Nicholas F.; Wiebe, David J.

    2017-09-12

    A turbine airfoil is provided with at least one insert positioned in a cavity in an airfoil interior. The insert extends along a span-wise extent of the turbine airfoil and includes first and second opposite faces. A first near-wall cooling channel is defined between the first face and a pressure sidewall of an airfoil outer wall. A second near-wall cooling channel is defined between the second face and a suction sidewall of the airfoil outer wall. The insert is configured to occupy an inactive volume in the airfoil interior so as to displace a coolant flow in the cavity toward the first and second near-wall cooling channels. A locating feature engages the insert with the outer wall for supporting the insert in position. The locating feature is configured to control flow of the coolant through the first or second near-wall cooling channel.

  16. User friendly packaging

    DEFF Research Database (Denmark)

    Geert Jensen, Birgitte

    2010-01-01

    Most consumers have experienced occasional problems with opening packaging. Tomato sauce from the tinned mackerel splattered all over the kitchen counter, the unrelenting pickle jar lid, and the package of sliced ham that cannot be opened without a knife or a pair of scissors. The research project...... “User-friendly Packaging” aims to create a platform for developing more user-friendly packaging. One intended outcome of the project is a guideline that industry can use in development efforts. The project also points the way for more extended collaboration between companies and design researchers. How...... can design research help industry in packaging innovation?...

  17. The R package 'icosa' for coarse resolution global triangular and penta-hexagonal gridding

    Science.gov (United States)

    Kocsis, Adam T.

    2017-04-01

    With the development of the internet and the computational power of personal computers, open source programming environments have become indispensable for science in the past decade. This includes the increase of the GIS capacity of the free R environment, which was originally developed for statistical analyses. The flexibility of R made it a preferred programming tool in a multitude of disciplines from the area of the biological and geological sciences. Many of these subdisciplines operate with incidence (occurrence) data that are in a large number of cases to be grained before further analyses can be conducted. This graining is executed mostly by gridding data to cells of a Gaussian grid of various resolutions to increase the density of data in a single unit of the analyses. This method has obvious shortcomings despite the ease of its application: well-known systematic biases are induced to cell sizes and shapes that can interfere with the results of statistical procedures, especially if the number of incidence points influences the metrics in question. The 'icosa' package employs a common method to overcome this obstacle by implementing grids with roughly equal cell sizes and shapes that are based on tessellated icosahedra. These grid objects are essentially polyhedra with xyz Cartesian vertex data that are linked to tables of faces and edges. At its current developmental stage, the package uses a single method of tessellation which balances grid cell size and shape distortions, but its structure allows the implementation of various other types of tessellation algorithms. The resolution of the grids can be set by the number of breakpoints inserted into a segment forming an edge of the original icosahedron. Both the triangular and their inverted penta-hexagonal grids are available for creation with the package. The package also incorporates functions to look up coordinates in the grid very effectively and data containers to link data to the grid structure. The

  18. Insertion devices at the advanced photon source

    International Nuclear Information System (INIS)

    Moog, E.R.

    1996-01-01

    The insertion devices being installed at the Advanced Photon Source cause the stored particle beam to wiggle, emitting x-rays with each wiggle. These x-rays combine to make an intense beam of radiation. Both wiggler and undulator types of insertion devices are being installed; the characteristics of the radiation produced by these two types of insertion devices are discussed, along with the reasons for those characteristics

  19. Packaging Review Guide for Reviewing Safety Analysis Reports for Packagings

    Energy Technology Data Exchange (ETDEWEB)

    DiSabatino, A; Biswas, D; DeMicco, M; Fisher, L E; Hafner, R; Haslam, J; Mok, G; Patel, C; Russell, E

    2007-04-12

    This Packaging Review Guide (PRG) provides guidance for Department of Energy (DOE) review and approval of packagings to transport fissile and Type B quantities of radioactive material. It fulfills, in part, the requirements of DOE Order 460.1B for the Headquarters Certifying Official to establish standards and to provide guidance for the preparation of Safety Analysis Reports for Packagings (SARPs). This PRG is intended for use by the Headquarters Certifying Official and his or her review staff, DOE Secretarial offices, operations/field offices, and applicants for DOE packaging approval. This PRG is generally organized at the section level in a format similar to that recommended in Regulatory Guide 7.9 (RG 7.9). One notable exception is the addition of Section 9 (Quality Assurance), which is not included as a separate chapter in RG 7.9. Within each section, this PRG addresses the technical and regulatory bases for the review, the manner in which the review is accomplished, and findings that are generally applicable for a package that meets the approval standards. This Packaging Review Guide (PRG) provides guidance for DOE review and approval of packagings to transport fissile and Type B quantities of radioactive material. It fulfills, in part, the requirements of DOE O 460.1B for the Headquarters Certifying Official to establish standards and to provide guidance for the preparation of Safety Analysis Reports for Packagings (SARPs). This PRG is intended for use by the Headquarters Certifying Official and his review staff, DOE Secretarial offices, operations/field offices, and applicants for DOE packaging approval. The primary objectives of this PRG are to: (1) Summarize the regulatory requirements for package approval; (2) Describe the technical review procedures by which DOE determines that these requirements have been satisfied; (3) Establish and maintain the quality and uniformity of reviews; (4) Define the base from which to evaluate proposed changes in scope

  20. Experimental testing of exchangeable cutting inserts cutting ability

    OpenAIRE

    Čep, Robert; Janásek, Adam; Čepová, Lenka; Petrů, Jana; Hlavatý, Ivo; Car, Zlatan; Hatala, Michal

    2013-01-01

    The article deals with experimental testing of the cutting ability of exchangeable cutting inserts. Eleven types of exchangeable cutting inserts from five different manufacturers were tested. The tested cutting inserts were of the same shape and were different especially in material and coating types. The main aim was both to select a suitable test for determination of the cutting ability of exchangeable cutting inserts and to design such testing procedure that could make it possible...

  1. DNA Packaging by λ-Like Bacteriophages: Mutations Broadening the Packaging Specificity of Terminase, the λ-Packaging Enzyme

    OpenAIRE

    Feiss, Michael; Reynolds, Erin; Schrock, Morgan; Sippy, Jean

    2010-01-01

    The DNA-packaging specificities of phages λ and 21 depend on the specific DNA interactions of the small terminase subunits, which have support helix-turn-recognition helix-wing DNA-binding motifs. λ-Terminase with the recognition helix of 21 preferentially packages 21 DNA. This chimeric terminase's ability to package λDNA is reduced ∼20-fold. Phage λ with the chimeric terminase is unable to form plaques, but pseudorevertants are readily obtained. Some pseudorevertants have trans-acting suppre...

  2. Life cycle assessment of EPS and CPB inserts: design considerations and end of life scenarios.

    Science.gov (United States)

    Tan, Reginald B H; Khoo, Hsien H

    2005-02-01

    Expanded polystyrene (EPS) and corrugated paperboard (CPB) are used in many industrial applications, such as containers, shock absorbers or simply as inserts. Both materials pose two different types of environmental problems. The first is the pollution and resource consumption that occur during the production of these materials; the second is the growing landfills that arise out of the excessive disposal of these packaging materials. Life cycle assessment or LCA will be introduced in this paper as a useful tool to compare the environmental performance of both EPS and CPB throughout their life cycle stages. This paper is divided into two main parts. The first part investigates the environmental impacts of the production of EPS and CPB from 'cradle-to-gate', comparing two inserts--both the original and proposed new designs. In the second part, LCA is applied to investigate various end-of-life cases for the same materials. The study will evaluate the environmental impacts of the present waste management practices in Singapore. Several 'what-if' cases are also discussed, including various percentages of landfilling and incineration. The SimaPro LCA Version 5.0 software's Eco-indicator 99 method is used to investigate the following five environmental impact categories: climate change, acidification/eutrophication, ecotoxicity, fossil fuels and respiratory inorganics.

  3. The paradox of packaging optimization – a characterization of packaging source reduction in the Netherlands

    NARCIS (Netherlands)

    van Sluisveld, M.A.E.; Worrell, E.

    2013-01-01

    The European Council Directive 94/62/EC for Packaging and Packaging Waste requires that Member States implement packaging waste prevention measures. However, consumption and subsequently packaging waste figures are still growing annually. It suggests that policies to accomplish packaging waste

  4. Prevention policies addressing packaging and packaging waste: Some emerging trends.

    Science.gov (United States)

    Tencati, Antonio; Pogutz, Stefano; Moda, Beatrice; Brambilla, Matteo; Cacia, Claudia

    2016-10-01

    Packaging waste is a major issue in several countries. Representing in industrialized countries around 30-35% of municipal solid waste yearly generated, this waste stream has steadily grown over the years even if, especially in Europe, specific recycling and recovery targets have been fixed. Therefore, an increasing attention starts to be devoted to prevention measures and interventions. Filling a gap in the current literature, this explorative paper is a first attempt to map the increasingly important phenomenon of prevention policies in the packaging sector. Through a theoretical sampling, 11 countries/states (7 in and 4 outside Europe) have been selected and analyzed by gathering and studying primary and secondary data. Results show evidence of three specific trends in packaging waste prevention policies: fostering the adoption of measures directed at improving packaging design and production through an extensive use of the life cycle assessment; raising the awareness of final consumers by increasing the accountability of firms; promoting collaborative efforts along the packaging supply chains. Copyright © 2016 Elsevier Ltd. All rights reserved.

  5. Food packages for Space Shuttle

    Science.gov (United States)

    Fohey, M. F.; Sauer, R. L.; Westover, J. B.; Rockafeller, E. F.

    1978-01-01

    The paper reviews food packaging techniques used in space flight missions and describes the system developed for the Space Shuttle. Attention is directed to bite-size food cubes used in Gemini, Gemini rehydratable food packages, Apollo spoon-bowl rehydratable packages, thermostabilized flex pouch for Apollo, tear-top commercial food cans used in Skylab, polyethylene beverage containers, Skylab rehydratable food package, Space Shuttle food package configuration, duck-bill septum rehydration device, and a drinking/dispensing nozzle for Space Shuttle liquids. Constraints and testing of packaging is considered, a comparison of food package materials is presented, and typical Shuttle foods and beverages are listed.

  6. In-Package Chemistry Abstraction

    Energy Technology Data Exchange (ETDEWEB)

    E. Thomas

    2004-11-09

    This report was developed in accordance with the requirements in ''Technical Work Plan for: Regulatory Integration Modeling and Analysis of the Waste Form and Waste Package'' (BSC 2004 [DIRS 171583]). The purpose of the in-package chemistry model is to predict the bulk chemistry inside of a breached waste package and to provide simplified expressions of that chemistry as function of time after breach to Total Systems Performance Assessment for the License Application (TSPA-LA). The scope of this report is to describe the development and validation of the in-package chemistry model. The in-package model is a combination of two models, a batch reactor model that uses the EQ3/6 geochemistry-modeling tool, and a surface complexation model that is applied to the results of the batch reactor model. The batch reactor model considers chemical interactions of water with the waste package materials and the waste form for commercial spent nuclear fuel (CSNF) waste packages and codisposed waste packages that contain both high-level waste glass (HLWG) and DOE spent fuel. The surface complexation model includes the impact of fluid-surface interactions (i.e., surface complexation) on the resulting fluid composition. The model examines two types of water influx: (1) the condensation of water vapor that diffuses into the waste package, and (2) seepage water that enters the waste package from the drift as a liquid. (1) Vapor Influx Case: The condensation of vapor onto the waste package internals is simulated as pure H2O and enters at a rate determined by the water vapor pressure for representative temperature and relative humidity conditions. (2) Water Influx Case: The water entering a waste package from the drift is simulated as typical groundwater and enters at a rate determined by the amount of seepage available to flow through openings in a breached waste package. TSPA-LA uses the vapor influx case for the nominal scenario for simulations where the waste

  7. In-Package Chemistry Abstraction

    International Nuclear Information System (INIS)

    E. Thomas

    2004-01-01

    This report was developed in accordance with the requirements in ''Technical Work Plan for: Regulatory Integration Modeling and Analysis of the Waste Form and Waste Package'' (BSC 2004 [DIRS 171583]). The purpose of the in-package chemistry model is to predict the bulk chemistry inside of a breached waste package and to provide simplified expressions of that chemistry as function of time after breach to Total Systems Performance Assessment for the License Application (TSPA-LA). The scope of this report is to describe the development and validation of the in-package chemistry model. The in-package model is a combination of two models, a batch reactor model that uses the EQ3/6 geochemistry-modeling tool, and a surface complexation model that is applied to the results of the batch reactor model. The batch reactor model considers chemical interactions of water with the waste package materials and the waste form for commercial spent nuclear fuel (CSNF) waste packages and codisposed waste packages that contain both high-level waste glass (HLWG) and DOE spent fuel. The surface complexation model includes the impact of fluid-surface interactions (i.e., surface complexation) on the resulting fluid composition. The model examines two types of water influx: (1) the condensation of water vapor that diffuses into the waste package, and (2) seepage water that enters the waste package from the drift as a liquid. (1) Vapor Influx Case: The condensation of vapor onto the waste package internals is simulated as pure H2O and enters at a rate determined by the water vapor pressure for representative temperature and relative humidity conditions. (2) Water Influx Case: The water entering a waste package from the drift is simulated as typical groundwater and enters at a rate determined by the amount of seepage available to flow through openings in a breached waste package. TSPA-LA uses the vapor influx case for the nominal scenario for simulations where the waste package has been

  8. Radioactive material packaging performance testing

    International Nuclear Information System (INIS)

    Romano, T.; Cruse, J.M.

    1991-02-01

    To provide uniform packaging of hazardous materials on an international level, the United Nations has developed packaging recommendations that have been implemented worldwide. The United Nations packaging recommendations are performance oriented, allowing for a wide variety of package materials and systems. As a result of this international standard, efforts in the United States are being directed toward use of performance-oriented packaging and elimination of specification (designed) packaging. This presentation will focus on trends, design evaluation, and performance testing of radioactive material packaging. The impacts of US Department of Transportation Dockets HM-181 and HM-169A on specification and low-specific activity radioactive material packaging requirements are briefly discussed. The US Department of Energy's program for evaluating radioactive material packings per US Department of Transportation Specification 7A Type A requirements, is used as the basis for discussing low-activity packaging performance test requirements. High-activity package testing requirements are presented with examples of testing performed at the Hanford Site that is operated by Westinghouse Hanford Company for the US Department of Energy. 5 refs., 2 tabs

  9. Ocular inserts - Advancement in therapy of eye diseases

    Directory of Open Access Journals (Sweden)

    Anita Kumari

    2010-01-01

    Full Text Available The ocular insert represents a significant advancement in the therapy of eye disease. Ocular inserts are defined as sterile, thin, multilayered, drug-impregnated, solid or semisolid consistency devices placed into the cul-de-sac or conjuctival sac, whose size and shape are especially designed for ophthalmic application. They are composed of a polymeric support that may or may not contain a drug. The drug can later be incorporated as dispersion or a solution in the polymeric support. They offer several advantages as increased ocular residence and sustained release of medication into the eye. The insert includes a body portion sized to position within a lachrymal canaliculus of the eyelid. The inserts are classified according to their solubility as insoluble, soluble, or bioerodible inserts. The release of drug from the insert depends upon the diffusion, osmosis, and bioerosion of the drug, and this article is an attempt to present a brief about this newer drug delivery system.

  10. Report on converging insert moulding with µ-IM

    DEFF Research Database (Denmark)

    Islam, Aminul

    moulding with µ-IM  Task 5.2.1 and COTECH demonstrator: guide line for 5PRC production based on the concept of Task 5.2.1 Information and results provided by this deliverable will be directly used for one of the COTECH demonstrators production which will call for convergent insert moulding with µ......Task 5.2.1 deals with the technical feasibility of converging the state-of-the-art µ IM process with insert moulding to offer a wide range of multi-material µ components. The main objective of this deliverable is to summarize state-of-the-art information and to make the guideline needed...... for the convergence. In particular the following aspects are summed up in the deliverable:  Need for converging insert moulding with µ-IM  Objectives and expected outcome from task 5.2.1  State-of-the-art micro insert moulding and different scenario of micro insert moulding  Challenges ahead of converging insert...

  11. Experimental and theoretical analyses of package-on-package structure under three-point bending loading

    International Nuclear Information System (INIS)

    Jia Su; Wang Xi-Shu; Ren Huai-Hui

    2012-01-01

    High density packaging is developing toward miniaturization and integration, which causes many difficulties in designing, manufacturing, and reliability testing. Package-on-Package (PoP) is a promising three-dimensional high-density packaging method that integrates a chip scale package (CSP) in the top package and a fine-pitch ball grid array (FBGA) in the bottom package. In this paper, in-situ scanning electron microscopy (SEM) observation is carried out to detect the deformation and damage of the PoP structure under three-point bending loading. The results indicate that the cracks occur in the die of the top package, then cause the crack deflection and bridging in the die attaching layer. Furthermore, the mechanical principles are used to analyse the cracking process of the PoP structure based on the multi-layer laminating hypothesis and the theoretical analysis results are found to be in good agreement with the experimental results. (condensed matter: structural, mechanical, and thermal properties)

  12. WASTE PACKAGE TRANSPORTER DESIGN

    International Nuclear Information System (INIS)

    Weddle, D.C.; Novotny, R.; Cron, J.

    1998-01-01

    The purpose of this Design Analysis is to develop preliminary design of the waste package transporter used for waste package (WP) transport and related functions in the subsurface repository. This analysis refines the conceptual design that was started in Phase I of the Viability Assessment. This analysis supports the development of a reliable emplacement concept and a retrieval concept for license application design. The scope of this analysis includes the following activities: (1) Assess features of the transporter design and evaluate alternative design solutions for mechanical components. (2) Develop mechanical equipment details for the transporter. (3) Prepare a preliminary structural evaluation for the transporter. (4) Identify and recommend the equipment design for waste package transport and related functions. (5) Investigate transport equipment interface tolerances. This analysis supports the development of the waste package transporter for the transport, emplacement, and retrieval of packaged radioactive waste forms in the subsurface repository. Once the waste containers are closed and accepted, the packaged radioactive waste forms are termed waste packages (WP). This terminology was finalized as this analysis neared completion; therefore, the term disposal container is used in several references (i.e., the System Description Document (SDD)) (Ref. 5.6). In this analysis and the applicable reference documents, the term ''disposal container'' is synonymous with ''waste package''

  13. Machinability and scratch wear resistance of carbon-coated WC inserts

    Energy Technology Data Exchange (ETDEWEB)

    Pazhanivel, B., E-mail: palcecri@yahoo.co.in; Kumar, T. Prem; Sozhan, G.

    2015-03-15

    Highlights: • Cemented WC inserts were coated with carbon by CVD. • The deposits were either loosely held MWCNTs or adherent carbides. • Co-efficient of friction (ramp load; 1–13 N); 0.2 and 0.1 μ, respectively, for the uncoated and carbide-coated inserts. • The carbide-coated insert exhibited better machinability and surface finish than a commercial TiCN-coated insert. - Abstract: In this work, cemented tungsten carbide (WC) inserts were coated with nanocarbons/carbides by chemical vapor deposition (CVD) and their machinability and scratch wear resistance were investigated. The hardness and surface conditions of the WC substrate were studied before and after coating. The CVD-generated nanocarbons on the insert surfaces were examined by SEM, FE-SEM and TEM. The electron microscopic images revealed that the carbons generated were multi-walled carbon nanotubes (MWCNTs) or carbides depending on the experimental conditions. In both the cases, the cutting edges of the inserts had dense deposits. Scratch wear test with the coated inserts showed that the co-efficient of friction was 0.1 μ as against 0.2 μ for the uncoated inserts under a ramp load of 1–13 N. The machinability characteristics of commercially available TiCN-coated inserts and the carbon-coated WC inserts were compared by using a CNC machine and a Rapid I vision inspection system. It was found that the carbide-coated inserts exhibited machinability with better surface finish comparable to that of the TiCN-coated inserts while the MWCNT-coated inserts showed inferior adhesion properties.

  14. BAHAN PENYERAP KMnO4 DAN ASAM L-ASKORBAT DALAM PENGEMASAN AKTIF (ACTIVE PACKAGING UNTUK MEMPERPANJANG MASA SIMPAN DAN MEMPERTAHANKAN MUTU BUAH DUKU (Lansium domesticum Corr. [Adsorbers for KMnO4 and L-Ascorbic Acid in the Active Packaging to Prolong the Shelve-Life and Maintain the Quality of Lanzone (Lansium domesticum Corr. Fruits

    Directory of Open Access Journals (Sweden)

    Soesiladi E Widodo

    2005-08-01

    Full Text Available To develop an active packaging of lanzone (Lansium domisticum Corr. Fruits, KmnO4 as an ethylene scavenger and L-ascorbic acid as an oxygent scavenger were inserted into packaging. As direct contact of KmnO4 with agricultural product was not recommended and due to the liquid characteristic of both scavenger was carried out. This research was aimed at finding out the best adsorbers for KmnO4, L-ascorbic acid, and their combination in an active packaging to prolog the shelve-life and to maintain the quality of lanzone fruits. The result showed that 1 among the four adsorbers tested, pumice could was the best alternative as a KmnO4 or L-ascorbic acid adsorbers, and 2 spon and pumice were the best alternative adsorber for the combination of KmnO4 or L-ascorbic acid. Both adsorber were effective in prolonging the shelve-live (8-11 days longer than with out packaging and as good as using silica gel and vermiculite and maintaining the quality of lanzone fruits.

  15. Node insertion in Coalescence Fractal Interpolation Function

    International Nuclear Information System (INIS)

    Prasad, Srijanani Anurag

    2013-01-01

    The Iterated Function System (IFS) used in the construction of Coalescence Hidden-variable Fractal Interpolation Function (CHFIF) depends on the interpolation data. The insertion of a new point in a given set of interpolation data is called the problem of node insertion. In this paper, the effect of insertion of new point on the related IFS and the Coalescence Fractal Interpolation Function is studied. Smoothness and Fractal Dimension of a CHFIF obtained with a node are also discussed

  16. Test manufacture of the canister insert 135

    International Nuclear Information System (INIS)

    Raiko, H.

    2005-10-01

    This report describes the insert-manufacturing test of a disposal canister for spent nuclear fuel that was made by Metso Foundries Jyvaeskylae Oy, in June 2004 on contract for Posiva Oy. The test manufacture was a part of the co-operation development programme of encapsulation technology between SKB AB and Posiva Oy. Insert casting was specified according to the current manufacturing specifications of SKB. The canister insert was of BWR-type with integral bottom. This was the second trial manufacture of this type of insert in Finland and, in total, the third test manufacture of insert by Metso Foundries Jyvaeskylae Oy. The result fulfilled all the requirements but the material mechanical properties of the cast material. The measured ultimate strength and elongation at rupture were lower than specified in the upper part of the cast. The reason for this was revealed in the metallurgical investigation of the cast material. The cast contained slag (dross). Avoiding the dross formation will be the most demanding challenge of the forthcoming development of the cast procedure. (orig.)

  17. Components of Adenovirus Genome Packaging

    Science.gov (United States)

    Ahi, Yadvinder S.; Mittal, Suresh K.

    2016-01-01

    Adenoviruses (AdVs) are icosahedral viruses with double-stranded DNA (dsDNA) genomes. Genome packaging in AdV is thought to be similar to that seen in dsDNA containing icosahedral bacteriophages and herpesviruses. Specific recognition of the AdV genome is mediated by a packaging domain located close to the left end of the viral genome and is mediated by the viral packaging machinery. Our understanding of the role of various components of the viral packaging machinery in AdV genome packaging has greatly advanced in recent years. Characterization of empty capsids assembled in the absence of one or more components involved in packaging, identification of the unique vertex, and demonstration of the role of IVa2, the putative packaging ATPase, in genome packaging have provided compelling evidence that AdVs follow a sequential assembly pathway. This review provides a detailed discussion on the functions of the various viral and cellular factors involved in AdV genome packaging. We conclude by briefly discussing the roles of the empty capsids, assembly intermediates, scaffolding proteins, portal vertex and DNA encapsidating enzymes in AdV assembly and packaging. PMID:27721809

  18. Genome packaging in viruses

    OpenAIRE

    Sun, Siyang; Rao, Venigalla B.; Rossmann, Michael G.

    2010-01-01

    Genome packaging is a fundamental process in a viral life cycle. Many viruses assemble preformed capsids into which the genomic material is subsequently packaged. These viruses use a packaging motor protein that is driven by the hydrolysis of ATP to condense the nucleic acids into a confined space. How these motor proteins package viral genomes had been poorly understood until recently, when a few X-ray crystal structures and cryo-electron microscopy structures became available. Here we discu...

  19. Numerical investigation of heat transfer and friction factor characteristics in a circular tube fitted with V-cut twisted tape inserts.

    Science.gov (United States)

    Salman, Sami D; Kadhum, Abdul Amir H; Takriff, Mohd S; Mohamad, Abu Bakar

    2013-01-01

    Numerical investigation of the heat transfer and friction factor characteristics of a circular fitted with V-cut twisted tape (VCT) insert with twist ratio (y = 2.93) and different cut depths (w = 0.5, 1, and 1.5 cm) were studied for laminar flow using CFD package (FLUENT-6.3.26). The data obtained from plain tube were verified with the literature correlation to ensure the validation of simulation results. Classical twisted tape (CTT) with different twist ratios (y = 2.93, 3.91, 4.89) were also studied for comparison. The results show that the enhancement of heat transfer rate induced by the classical and V-cut twisted tape inserts increases with the Reynolds number and decreases with twist ratio. The results also revealed that the V-cut twisted tape with twist ratio y = 2.93 and cut depth w = 0.5 cm offered higher heat transfer rate with significant increases in friction factor than other tapes. In addition the results of V-cut twist tape compared with experimental and simulated data of right-left helical tape inserts (RLT), it is found that the V-cut twist tape offered better thermal contact between the surface and the fluid which ultimately leads to a high heat transfer coefficient. Consequently, 107% of maximum heat transfer was obtained by using this configuration.

  20. Templated sequence insertion polymorphisms in the human genome

    Science.gov (United States)

    Onozawa, Masahiro; Aplan, Peter

    2016-11-01

    Templated Sequence Insertion Polymorphism (TSIP) is a recently described form of polymorphism recognized in the human genome, in which a sequence that is templated from a distant genomic region is inserted into the genome, seemingly at random. TSIPs can be grouped into two classes based on nucleotide sequence features at the insertion junctions; Class 1 TSIPs show features of insertions that are mediated via the LINE-1 ORF2 protein, including 1) target-site duplication (TSD), 2) polyadenylation 10-30 nucleotides downstream of a “cryptic” polyadenylation signal, and 3) preference for insertion at a 5’-TTTT/A-3’ sequence. In contrast, class 2 TSIPs show features consistent with repair of a DNA double-strand break via insertion of a DNA “patch” that is derived from a distant genomic region. Survey of a large number of normal human volunteers demonstrates that most individuals have 25-30 TSIPs, and that these TSIPs track with specific geographic regions. Similar to other forms of human polymorphism, we suspect that these TSIPs may be important for the generation of human diversity and genetic diseases.

  1. Insertion Loss of Personal Protective Clothing

    International Nuclear Information System (INIS)

    Shull, D.J.

    1999-01-01

    The use of personal protective clothing that covers the head is a common practice in many industries. Such personal protective clothing will impact the sound pressure level and the frequency content of sounds to which the wearer will be exposed. The use of such clothing, then, may impact speech and alarm audibility. A measure of the impact of such clothing is its insertion loss. Insertion loss measurements were performed on four types of personal protective clothing in use by Westinghouse Savannah River Company personnel which utilize cloth and plastic hood configurations to protect the head. All clothing configurations tested at least partially cover the ears. The measurements revealed that insertion loss of the items tested was notable at frequencies above 1000 Hz only and was a function of material stiffness and acoustic flanking paths to the ear. Further, an estimate of the clothing's noise reduction rating reveals poor performance in that regard, even though the insertion loss of the test articles was significant at frequencies at and above 1000 Hz.'

  2. Food packaging history and innovations.

    Science.gov (United States)

    Risch, Sara J

    2009-09-23

    Food packaging has evolved from simply a container to hold food to something today that can play an active role in food quality. Many packages are still simply containers, but they have properties that have been developed to protect the food. These include barriers to oxygen, moisture, and flavors. Active packaging, or that which plays an active role in food quality, includes some microwave packaging as well as packaging that has absorbers built in to remove oxygen from the atmosphere surrounding the product or to provide antimicrobials to the surface of the food. Packaging has allowed access to many foods year-round that otherwise could not be preserved. It is interesting to note that some packages have actually allowed the creation of new categories in the supermarket. Examples include microwave popcorn and fresh-cut produce, which owe their existence to the unique packaging that has been developed.

  3. Trends in Food Packaging.

    Science.gov (United States)

    Ott, Dana B.

    1988-01-01

    This article discusses developments in food packaging, processing, and preservation techniques in terms of packaging materials, technologies, consumer benefits, and current and potential food product applications. Covers implications due to consumer life-style changes, cost-effectiveness of packaging materials, and the ecological impact of…

  4. WASTE PACKAGE TRANSPORTER DESIGN

    Energy Technology Data Exchange (ETDEWEB)

    D.C. Weddle; R. Novotny; J. Cron

    1998-09-23

    The purpose of this Design Analysis is to develop preliminary design of the waste package transporter used for waste package (WP) transport and related functions in the subsurface repository. This analysis refines the conceptual design that was started in Phase I of the Viability Assessment. This analysis supports the development of a reliable emplacement concept and a retrieval concept for license application design. The scope of this analysis includes the following activities: (1) Assess features of the transporter design and evaluate alternative design solutions for mechanical components. (2) Develop mechanical equipment details for the transporter. (3) Prepare a preliminary structural evaluation for the transporter. (4) Identify and recommend the equipment design for waste package transport and related functions. (5) Investigate transport equipment interface tolerances. This analysis supports the development of the waste package transporter for the transport, emplacement, and retrieval of packaged radioactive waste forms in the subsurface repository. Once the waste containers are closed and accepted, the packaged radioactive waste forms are termed waste packages (WP). This terminology was finalized as this analysis neared completion; therefore, the term disposal container is used in several references (i.e., the System Description Document (SDD)) (Ref. 5.6). In this analysis and the applicable reference documents, the term ''disposal container'' is synonymous with ''waste package''.

  5. Insertable fluid flow passage bridgepiece and method

    Science.gov (United States)

    Jones, Daniel O.

    2000-01-01

    A fluid flow passage bridgepiece for insertion into an open-face fluid flow channel of a fluid flow plate is provided. The bridgepiece provides a sealed passage from a columnar fluid flow manifold to the flow channel, thereby preventing undesirable leakage into and out of the columnar fluid flow manifold. When deployed in the various fluid flow plates that are used in a Proton Exchange Membrane (PEM) fuel cell, bridgepieces of this invention prevent mixing of reactant gases, leakage of coolant or humidification water, and occlusion of the fluid flow channel by gasket material. The invention also provides a fluid flow plate assembly including an insertable bridgepiece, a fluid flow plate adapted for use with an insertable bridgepiece, and a method of manufacturing a fluid flow plate with an insertable fluid flow passage bridgepiece.

  6. Retention and penetration of a conventional resin-based sealant and a photochromatic flowable composite resin placed on occlusal pits and fissures

    Directory of Open Access Journals (Sweden)

    Aguilar F

    2007-01-01

    Full Text Available This study compares the retention and penetration of a conventional resin-based sealant (Fluroshield and a photochromatic flowable composite resin (Tetric Flow Chroma placed on occlusal pits and fissures and submitted to thermal or chemical cycling regimens. Penetration assessment - ten premolars were sealed with each material, isolated (except for the sealed surface and immersed in 0.2% Rhodamine B. The teeth were serially sectioned in a mesiodistal direction. The images of the sections were digitized and analyzed (ImageLab. The distance between the most superficial and the deepest points on the occlusal central groove was calculated to determine the groove′s total depth. The length of the central groove filled with the sealant was divided by its total depth to obtain the percentage of sealing of the occlusal groove. Retention assessment - 30 premolars were sealed, their occlusal surfaces were photographed and the area occupied by the sealing materials was demarcated (ImageLab. The teeth were submitted to different treatments: thermocycled, stored in artificial saliva and immersed in acetic acid and saliva (10 cycles/day protocol for 30 days. New photographs were taken to assess the final area occupied by the materials. The difference between the final and initial area was calculated to obtain the material loss. The data was analyzed (two-way anova and Tukey′s test P < 0.05. Both materials presented similar penetration of the occlusal central groove. After thermal and chemical cycling, the materials did not differ with respect to retention, except for immersion in acetic acid. In this case, Tetric Flow Chroma presented greater retention than Fluoroshield.

  7. Development of collimator insert for linac based stereotactic irradiation

    International Nuclear Information System (INIS)

    Singh, I.R.R.; Brindha, S.; Ravindran, B.P.; Rajshekhar, V.

    1999-01-01

    The aim of this study is to develop collimator inserts of various sizes which are either not commercially available or are expensive to import. The dosimetry parameters such as tissue maximum ratio (TMR), off-axis ratio (OAR) and output factor of the developed collimator insert are compared with that of the commercial collimator insert (Radionics). In order to check the suitability of the collimator insert developed locally for clinical use and to standardize the method of development, a collimator insert of 15 mm identical to the one supplied by Radionics is developed with low-melting alloy (Cerrobend). Moreover for the clinical use of the developed collimator insert, certain acceptance tests are performed which include a collimator concentricity test, beam size check and radiation leakage test. The dose verification is carried out with a thermoluminescent dosimeter ( 7 LiF rods) and an FBX chemical dosimeter in a human-head-shaped Perspex phantom filled with water. The variation between the calculated and measured dose is found to be within +2.4% for 7 LiF rods and -2.0% for the FBX chemical dosimeter thus ensuring the suitability of the developed collimator insert for clinical use. This has encouraged us to standardize the method adapted to develop the collimator insert and to develop collimator inserts of different field sizes. (author)

  8. Measurement of properties of sealant materials for solid oxide fuel cell systems

    International Nuclear Information System (INIS)

    Boersma, R.J.; Sammes, N.M.; Zhang, Y.

    1998-01-01

    Thermal expansion of ceramic materials, ceramic cements and steels was studied, and their compatibility with materials used in the SOFC system was evaluated. A number of ceramic cements, a glass paste and a glass ceramic were examined to identify their potential as a sealing material in a tubular fuel cell system. Thermal expansion coefficients of these materials were compared for thermal matching with materials employed in the fuel cell construction, such as yttria stabilised with 8 mole% zirconia (8YSZ) and stainless steel. A reasonable match was found for Macor, a glass ceramic, with one of the steel samples studied and with 8YSZ. Candidate sealants were tested for bonding quality, which made it evident that the ceramic cements had to be discarded. Good bonds between Macor and one of the steel samples and Macor and 8YSZ were formed, resulting in a gas tight seal. Uncertainty remains regarding the long term effect of the interface reactions between steel and Macor. Exposure of the Macor and a steel-Macor-8YSZ assembly to the different fuel cell gas atmospheres revealed that the Macor reacts with hydrogen, the long term effect of which is also unknown. Copyright (1998) Australasian Ceramic Society

  9. The Innovative Approaches to Packaging – Comparison Analysis of Intelligent and Active Packaging Perceptions in Slovakia

    Directory of Open Access Journals (Sweden)

    Loucanova Erika

    2017-06-01

    Full Text Available Packaging has always served a practical function - to hold goods together and protect it when moving toward the customer through distribution channel. Today packaging is also a container for promoting the product and making it easier and safer to use. The sheer importance of packaging functions is still growing and consequently the interest of the company is to access to the packaging more innovative and creative. The paper deals with the innovative approaches to packaging resulting in the creation of packaging with interactive active features in the form of active and intelligent packaging. Using comparative analysis, we monitored the perception of the active packaging functions in comparison to intelligent packaging function among different age categories. We identified the age categories which are most interested in these functions.

  10. Applications of Active Packaging in Breads

    Directory of Open Access Journals (Sweden)

    Ali Göncü

    2017-10-01

    Full Text Available Changes on consumer preferences lead to innovations and improvements in new packaging technologies. With these new developments passive packaging technologies aiming to protect food nowadays have left their place to active and intelligent packaging technologies that have other various functions beside protection of food. Active packaging is defined as an innovative packaging type and its usage increases the shelf life of food significantly. Applications of active packaging have begun to be used for packaging of breads. In this study active packaging applications in breads have been reviewed.

  11. Single-copy insertion of transgenes in Caenorhabditis elegans

    DEFF Research Database (Denmark)

    Frøkjaer-Jensen, Christian; Davis, M Wayne; Hopkins, Christopher E

    2008-01-01

    developed a method that inserts a single copy of a transgene into a defined site. Mobilization of a Mos1 transposon generates a double-strand break in noncoding DNA. The break is repaired by copying DNA from an extrachromosomal template into the chromosomal site. Homozygous single-copy insertions can...... be obtained in less than 2 weeks by injecting approximately 20 worms. We have successfully inserted transgenes as long as 9 kb and verified that single copies are inserted at the targeted site. Single-copy transgenes are expressed at endogenous levels and can be expressed in the female and male germlines....

  12. Laparoscopic insertion of the Moss feeding tube.

    Science.gov (United States)

    Albrink, M H; Hagan, K; Rosemurgy, A S

    1993-12-01

    Placement of enteral feeding tubes is an important part of a surgeon's skill base. Surgical insertion of feeding tubes has been performed safely for many years with very few modifications. With the recent surge in interest and applicability of other laparoscopic procedures, it is well within the skills of the average laparoscopic surgeon to insert feeding tubes. We describe herein a simple technique for the insertion of the Moss feeding tube. The procedure described has a minimum of invasion, along with simplicity, safety, and accuracy.

  13. Food Packaging Materials

    Science.gov (United States)

    1978-01-01

    The photos show a few of the food products packaged in Alure, a metallized plastic material developed and manufactured by St. Regis Paper Company's Flexible Packaging Division, Dallas, Texas. The material incorporates a metallized film originally developed for space applications. Among the suppliers of the film to St. Regis is King-Seeley Thermos Company, Winchester, Ma'ssachusetts. Initially used by NASA as a signal-bouncing reflective coating for the Echo 1 communications satellite, the film was developed by a company later absorbed by King-Seeley. The metallized film was also used as insulating material for components of a number of other spacecraft. St. Regis developed Alure to meet a multiple packaging material need: good eye appeal, product protection for long periods and the ability to be used successfully on a wide variety of food packaging equipment. When the cost of aluminum foil skyrocketed, packagers sought substitute metallized materials but experiments with a number of them uncovered problems; some were too expensive, some did not adequately protect the product, some were difficult for the machinery to handle. Alure offers a solution. St. Regis created Alure by sandwiching the metallized film between layers of plastics. The resulting laminated metallized material has the superior eye appeal of foil but is less expensive and more easily machined. Alure effectively blocks out light, moisture and oxygen and therefore gives the packaged food long shelf life. A major packaging firm conducted its own tests of the material and confirmed the advantages of machinability and shelf life, adding that it runs faster on machines than materials used in the past and it decreases product waste; the net effect is increased productivity.

  14. The Correlation between Insertion Depth of Prodisc-C Artificial Disc and Postoperative Kyphotic Deformity: Clinical Importance of Insertion Depth of Artificial Disc.

    Science.gov (United States)

    Lee, Do-Youl; Kim, Se-Hoon; Suh, Jung-Keun; Cho, Tai-Hyoung; Chung, Yong-Gu

    2012-09-01

    This study was designed to investigate the correlation between insertion depth of artificial disc and postoperative kyphotic deformity after Prodisc-C total disc replacement surgery, and the range of artificial disc insertion depth which is effective in preventing postoperative whole cervical or segmental kyphotic deformity. A retrospective radiological analysis was performed in 50 patients who had undergone single level total disc replacement surgery. Records were reviewed to obtain demographic data. Preoperative and postoperative radiographs were assessed to determine C2-7 Cobb's angle and segmental angle and to investigate postoperative kyphotic deformity. A formula was introduced to calculate insertion depth of Prodisc-C artificial disc. Statistical analysis was performed to search the correlation between insertion depth of Prodisc-C artificial disc and postoperative kyphotic deformity, and to estimate insertion depth of Prodisc-C artificial disc to prevent postoperative kyphotic deformity. In this study no significant statistical correlation was observed between insertion depth of Prodisc-C artificial disc and postoperative kyphotic deformity regarding C2-7 Cobb's angle. Statistical correlation between insertion depth of Prodisc-C artificial disc and postoperative kyphotic deformity was observed regarding segmental angle (p<0.05). It failed to estimate proper insertion depth of Prodisc-C artificial disc effective in preventing postoperative kyphotic deformity. Postoperative segmental kyphotic deformity is associated with insertion depth of Prodisc-C artificial disc. Anterior located artificial disc leads to lordotic segmental angle and posterior located artificial disc leads to kyphotic segmental angle postoperatively. But C2-7 Cobb's angle is not affected by artificial disc location after the surgery.

  15. HTS Insert Magnet Design Study

    CERN Document Server

    Devaux, M; Fleiter, J; Fazilleau, P; Lécrevisse, T; Pes, C; Rey, J-M; Rifflet, J-M; Sorbi, M; Stenvall, A; Tixador, P; Volpini, G

    2011-01-01

    Future accelerator magnets will need to reach higher field in the range of 20 T. This field level is very difficult to reach using only Low Temperature Superconductor materials whereas High Temperature Superconductors (HTS) provide interesting opportunities. High current densities and stress levels are needed to design such magnets. YBCO superconductor indeed carries large current densities under high magnetic field and provides good mechanical properties especially when produced using the IBAD approach. The HFM EUCARD program studies the design and the realization of an HTS insert of 6 T inside a Nb$_{3}$Sn dipole of 13T at 4.2 K. In the2HTS insert, engineering current densities higher than 250 MA/m under 19 T are required to fulfill the specifications. The stress level is also very severe. YBCO IBAD tapes theoretically meet these challenges from presented measurements. The insert protection is also a critical because HTS materials show low quench propagation velocities and the coupling with the Nb$_{3}$Sn m...

  16. Materials and structures technology insertion into spacecraft systems: Successes and challenges

    Science.gov (United States)

    Rawal, Suraj

    2018-05-01

    Over the last 30 years, significant advancements have led to the use of multifunctional materials and structures technologies in spacecraft systems. This includes the integration of adaptive structures, advanced composites, nanotechnology, and additive manufacturing technologies. Development of multifunctional structures has been directly influenced by the implementation of processes and tools for adaptive structures pioneered by Prof. Paolo Santini. Multifunctional materials and structures incorporating non-structural engineering functions such as thermal, electrical, radiation shielding, power, and sensors have been investigated. The result has been an integrated structure that offers reduced mass, packaging volume, and ease of integration for spacecraft systems. Current technology development efforts are being conducted to develop innovative multifunctional materials and structures designs incorporating advanced composites, nanotechnology, and additive manufacturing. However, these efforts offer significant challenges in the qualification and acceptance into spacecraft systems. This paper presents a brief overview of the technology development and successful insertion of advanced material technologies into spacecraft structures. Finally, opportunities and challenges to develop and mature next generation advanced materials and structures are presented.

  17. Plasma physics plotting package

    International Nuclear Information System (INIS)

    Hyman, D.H.

    1981-02-01

    We describe a package of plotting routines that do up to six two- or three-dimensional plots on a frame with minimal loss of resolution. The package now runs on a PDP-10 with PLOT-10 TCS primitives and on a Control Data Corporation-7600 and a Cray-1 with TV80LIB primitives on the National Magnetic Fusion Energy Computer Center network. The package is portable to other graphics systems because only the primitive plot calls are used from the underlying system's graphics package

  18. Active food packaging technologies.

    Science.gov (United States)

    Ozdemir, Murat; Floros, John D

    2004-01-01

    Active packaging technologies offer new opportunities for the food industry, in the preservation of foods. Important active packaging systems currently known to date, including oxygen scavengers, carbon dioxide emitters/absorbers, moisture absorbers, ethylene absorbers, ethanol emitters, flavor releasing/absorbing systems, time-temperature indicators, and antimicrobial containing films, are reviewed. The principle of operation of each active system is briefly explained. Recent technological advances in active packaging are discussed, and food related applications are presented. The effects of active packaging systems on food quality and safety are cited.

  19. Neutron absorber inserts for 55-gal drums

    International Nuclear Information System (INIS)

    Wilson, R.E.; Kim, Y.S.; Toffer, H.

    2000-01-01

    Transport and temporary storage of more than 200 g of fissile material in 55-gal drums at the Rocky Flats Environmental Technology Site (RFETS) have received significant attention during the cleanup mission. This paper discusses successful applications and results of extensive computer studies. Interim storage and movement of fissile material in excess of standard drum limits (200 g) in a safe configuration have been accomplished using special drum inserts. Such inserts have constrained the contents of a drum to two 4-ell bottles. The content of the bottles was limited to 600 g Pu or U in solution or a total of 1200 g for the entire drum. The inserts were a simple design constructed of stainless steel, forming a vertical cylindrical pipe into which two bottles, one on top of the other, could be centered in the drum. The remaining drum volume was configured to preclude any additional bottle placement external to the vertical cylinder. Such inserts in drums were successfully used in moving high-concentration solution from one building to another for chemical processing. Concern about the knowledge of fissile material concentration in bottles prompted another study for drum inserts. The past practice had been to load up to fourteen 4-ell bottles into 55-gal drums, provided the fissile material concentration was < 6 g fissile/ell, and the total drum contents of 200 g fissile was not exceeded. Only one determination of the solution concentration was needed. An extensive safety analysis concluded that a single measurement of bottle content could not ensure compliance with double-contingency-criterion requirements. A second determination of the bottle contents was required before bottles could be placed in a 55-gal drum. Al alternative to a dual-measurement protocol, which is for bolstering administrative control, was to develop an engineered safety feature that would eliminate expensive tests and administrative decisions. A drum insert design was evaluated that would

  20. Z-2 Threaded Insert Design and Testing

    Science.gov (United States)

    Ross, Amy; Rhodes, Richard; Jones, Robert J.; Graziosi, David; Ferl, Jinny; Sweeny, Mitch; Scarborough, Stephen

    2016-01-01

    NASA's Z-2 prototype space suit contains several components fabricated from an advanced hybrid composite laminate consisting of IM10 carbon fiber and fiber glass. One requirement was to have removable, replaceable helicoil inserts to which other suit components would be fastened. An approach utilizing bonded in inserts with helicoils inside of them was implemented. During initial assembly, cracking sounds were heard followed by the lifting of one of the blind inserts out of its hole when the screws were torqued. A failure investigation was initiated to understand the mechanism of the failure. Ultimately, it was determined that the pre-tension caused by torqueing the fasteners is a much larger force than induced from the pressure loads of the suit which was not considered in the insert design. Bolt tension is determined by dividing the torque on the screw by a k value multiplied by the thread diameter of the bolt. The k value is a factor that accounts for friction in the system. A common value used for k for a non-lubricated screw is 0.2. The k value can go down by as much as 0.1 if the screw is lubricated which means for the same torque, a much larger tension could be placed on the bolt and insert. This paper summarizes the failure investigation that was performed to identify the root cause of the suit failure and details how the insert design was modified to resist a higher pull out tension.

  1. Naval Waste Package Design Report

    International Nuclear Information System (INIS)

    M.M. Lewis

    2004-01-01

    A design methodology for the waste packages and ancillary components, viz., the emplacement pallets and drip shields, has been developed to provide designs that satisfy the safety and operational requirements of the Yucca Mountain Project. This methodology is described in the ''Waste Package Design Methodology Report'' Mecham 2004 [DIRS 166168]. To demonstrate the practicability of this design methodology, four waste package design configurations have been selected to illustrate the application of the methodology. These four design configurations are the 21-pressurized water reactor (PWR) Absorber Plate waste package, the 44-boiling water reactor (BWR) waste package, the 5-defense high-level waste (DHLW)/United States (U.S.) Department of Energy (DOE) spent nuclear fuel (SNF) Co-disposal Short waste package, and the Naval Canistered SNF Long waste package. Also included in this demonstration is the emplacement pallet and continuous drip shield. The purpose of this report is to document how that design methodology has been applied to the waste package design configurations intended to accommodate naval canistered SNF. This demonstrates that the design methodology can be applied successfully to this waste package design configuration and support the License Application for construction of the repository

  2. 49 CFR 173.24 - General requirements for packagings and packages.

    Science.gov (United States)

    2010-10-01

    ... identifiable (without the use of instruments) release of hazardous materials to the environment; (2) The effectiveness of the package will not be substantially reduced; for example, impact resistance, strength... significant chemical or galvanic reaction between the materials and contents of the package. (3) Plastic...

  3. Bulkhead insert for an internal combustion engine

    Science.gov (United States)

    Maki, Clifford E.; Chottiner, Jeffrey Eliot; Williams, Rick L.; Thibault, Mark W.; Ervin, James Douglas; Boileau, James Maurice; McKeough, Bryan

    2017-08-01

    An engine includes a cylinder block defining at least one main bearing bulkhead adjacent to a cylinder, and a crankshaft rotatably housed within the block by a main bearing. A bulkhead insert has a cap portion, and an insert portion provided within the bulkhead. The insert portion has having first and second end regions connected by first and second straps. Each strap having a flanged beam cross section. The first and second ends of the insert portion are configured to connect a main bearing cap column to a cylinder head column. Each of the first and second end regions define at least one protrusion having a surface substantially normal to engine combustion and reactive loads. The cap portion is configured to mate with the first end region at the main bearing cap column and support the main bearing.

  4. Packaging systems for animal origin food

    Directory of Open Access Journals (Sweden)

    2011-03-01

    Full Text Available The main task of food packaging is to protect the product during storage and transport against the action of biological, chemical and mechanical factors. The paper presents packaging systems for food of animal origin. Vacuum and modified atmosphere packagings were characterised together with novel types of packagings, referred to as intelligent packaging and active packaging. The aim of this paper was to present all advantages and disadvantages of packaging used for meat products. Such list enables to choose the optimal type of packaging for given assortment of food and specific conditions of the transport and storing.

  5. Lithium insertion mechanism in SnS2

    International Nuclear Information System (INIS)

    Lefebvre-Devos, I.; Olivier-Fourcade, J.; Jumas, J.C.; Lavela, P.

    2000-01-01

    We study lithium insertion in SnS 2 by means of 119 Sn Moessbauer spectroscopy, x-ray absorption spectroscopy at Sn L I,III , and S K edges, and theoretical electronic structures (calculated in the density-functional theory framework). An insertion mechanism is derived according to the Li amount. It shows the influence of the SnS 2 -layered structure on the Sn reduction, particularly the possibility of an intermediate oxidation state between Sn IV and Sn II , which is not observed during Li insertion in three-dimensional sulfides

  6. Merganser Download Package

    Data.gov (United States)

    U.S. Environmental Protection Agency — This data download package contains an Esri 10.0 MXD, file geodatabase and copy of this FGDC metadata record. The data in this package are used in support of the...

  7. Modular assembly of chimeric phi29 packaging RNAs that support DNA packaging.

    Science.gov (United States)

    Fang, Yun; Shu, Dan; Xiao, Feng; Guo, Peixuan; Qin, Peter Z

    2008-08-08

    The bacteriophage phi29 DNA packaging motor is a protein/RNA complex that can produce strong force to condense the linear-double-stranded DNA genome into a pre-formed protein capsid. The RNA component, called the packaging RNA (pRNA), utilizes magnesium-dependent inter-molecular base-pairing interactions to form ring-shaped complexes. The pRNA is a class of non-coding RNA, interacting with phi29 motor proteins to enable DNA packaging. Here, we report a two-piece chimeric pRNA construct that is fully competent in interacting with partner pRNA to form ring-shaped complexes, in packaging DNA via the motor, and in assembling infectious phi29 virions in vitro. This is the first example of a fully functional pRNA assembled using two non-covalently interacting fragments. The results support the notion of modular pRNA architecture in the phi29 packaging motor.

  8. The art of packaging: An investigation into the role of color in packaging, marketing, and branding

    Directory of Open Access Journals (Sweden)

    Behzad Mohebbi

    2014-12-01

    Full Text Available The purpose of this study is to contribute to the existing research in the field of packaging and marketing and shed more light on the psychology of colors and their effect on packaging and marketing. Nowadays, packaging is proved to be one of the significant factors in the success of promoting product sale. However, there is a perceived gap with respect to the different aspects of packaging, in particular the graphics, design, and color of packaging. The current study provides a comprehensive overview of packaging. It elaborates on different aspects of packaging and summarizes the findings of the most recent research conducted to date probing into packaging from different perspectives. It also discusses the role of color, i.e., the psychology of colors, and graphics in packaging and product sale. It is argued that graphics and color play key roles in promoting product sale and designers and marketers should attach a great deal of importance to color in packaging. The implications for producers, marketers, practitioners, and researchers are discussed in detail and suggestions for future research are provided.

  9. MINUIT package parallelization and applications using the RooFit package

    International Nuclear Information System (INIS)

    Lazzaro, Alfio; Moneta, Lorenzo

    2010-01-01

    The fitting procedures are based on numerical minimization of functions. The MINUIT package is the most common package used for such procedures in High Energy Physics community. The main algorithm in this package, MIGRAD, searches the minimum of a function using the gradient information. For each minimization iteration, MIGRAD requires the calculation of the derivative for each free parameter of the function to be minimized. Minimization is required for data analysis problems based on the maximum likelihood technique. The calculation of complex likelihood functions, with several free parameters, many independent variables and large data samples, can be very CPU-time consuming. Then, the minimization process requires the calculation of the likelihood functions several times for each minimization iteration. In this paper we will show how MIGRAD algorithm and the likelihood function calculation can be easily parallelized using Message Passing Interface techniques. We will present the speed-up improvements obtained in typical physics applications such as complex maximum likelihood fits using the RooFit package.

  10. Waste package performance analysis

    International Nuclear Information System (INIS)

    Lester, D.H.; Stula, R.T.; Kirstein, B.E.

    1982-01-01

    A performance assessment model for multiple barrier packages containing unreprocessed spent fuel has been applied to several package designs. The resulting preliminary assessments were intended for use in making decisions about package development programs. A computer model called BARIER estimates the package life and subsequent rate of release of selected nuclides. The model accounts for temperature, pressure (and resulting stresses), bulk and localized corrosion, and nuclide retardation by the backfill after water intrusion into the waste form. The assessment model assumes a post-closure, flooded, geologic repository. Calculations indicated that, within the bounds of model assumptions, packages could last for several hundred years. Intact backfills of appropriate design may be capable of nuclide release delay times on the order of 10 7 yr for uranium, plutonium, and americium. 8 references, 6 figures, 9 tables

  11. Comparative Packaging Study

    Science.gov (United States)

    Perchonok, Michele H.; Oziomek, Thomas V.

    2009-01-01

    Future long duration manned space flights beyond low earth orbit will require the food system to remain safe, acceptable and nutritious. Development of high barrier food packaging will enable this requirement by preventing the ingress and egress of gases and moisture. New high barrier food packaging materials have been identified through a trade study. Practical application of this packaging material within a shelf life test will allow for better determination of whether this material will allow the food system to meet given requirements after the package has undergone processing. The reason to conduct shelf life testing, using a variety of packaging materials, stems from the need to preserve food used for mission durations of several years. Chemical reactions that take place during longer durations may decrease food quality to a point where crew physical or psychological well-being is compromised. This can result in a reduction or loss of mission success. The rate of chemical reactions, including oxidative rancidity and staling, can be controlled by limiting the reactants, reducing the amount of energy available to drive the reaction, and minimizing the amount of water available. Water not only acts as a media for microbial growth, but also as a reactant and means by which two reactants may come into contact with each other. The objective of this study is to evaluate three packaging materials for potential use in long duration space exploration missions.

  12. Comparison of six different methods of cleaning and preparing occlusal fissure surface before placement of pit and fissure sealant: An in vitro study

    Directory of Open Access Journals (Sweden)

    A Agrawal

    2012-01-01

    Full Text Available Aim & Objectives : The purpose of this in vitro study was to evaluate and compare the microleakage of pit and fissure sealants after using six different preparation techniques: (a brush, (b pumice slurry application, (c bur, (d air polishing, (e air abrasion, and (f longer etching time. Material & Method : The study was conducted on 60 caries-free first premolars extracted for orthodontic purpose. These teeth were randomly assigned to six groups of 10 teeth each. Teeth were prepared using one of six occlusal surface treatments prior to placement of Clinpro" 3M ESPE light-cured sealant. The teeth were thermocycled for 500 cycles and stored in 0.9% normal saline. Teeth were sealed apically and coated with nail varnish 1 mm from the margin and stained in 1% methylene blue for 24 hours. Each tooth was divided buccolingually parallel to the long axis of the tooth, yielding two sections per tooth for analysis. The surfaces were scored from 0 to 2 for the extent of microleakage. Statistical Analysis : Results obtained for microleakage were analyzed by using t-tests at sectional level and chi-square test and analysis of variance (ANOVA at the group level. Results : The results of round bur group were significantly superior when compared to all other groups. The application of air polishing and air abrasion showed better results than pumice slurry, bristle brush, and longer etching time. Round bur group was the most successful cleaning and preparing technique. Air polishing and air abrasion produced significantly less microleakage than traditional pumice slurry, bristle brush, and longer etching time.

  13. Autologous but not Fibrin Sealant Patches for Stump Coverage Reduce Clinically Relevant Pancreatic Fistula in Distal Pancreatectomy: A Systematic Review and Meta-analysis.

    Science.gov (United States)

    Weniger, Maximilian; D'Haese, Jan Goesta; Crispin, Alexander; Angele, Martin Kurt; Werner, Jens; Hartwig, Werner

    2016-11-01

    Postoperative pancreatic fistula (POPF) causes significant morbidity and mortality after distal pancreatectomy. Patch coverage of the pancreatic stump is often used with the intention to prevent POPF. Despite numerous investigations, the effects of patch coverage remain unclear. The present meta-analysis aims to clarify the effects of patch coverage in distal pancreatectomy on the incidence of POPF. A systematic search of MEDLINE/PubMed and the Cochrane Database according to the PRISMA Statement was performed. Subsequently a meta-analysis on rates and overall incidence of POPF and length of hospital stay was carried out. By applying the inverse variance weighting method, the combined effect size and 95 % confidence interval were calculated. Heterogeneity was assessed using I 2 statistics. Five randomized controlled trials and six observational clinical studies were included for final analysis. A cumulative incidence of 43 % of POPF grades A-C was identified. Patch coverage in distal pancreatectomy is significantly associated with a decreased rate of POPF grade C (p = 0.006). Patches of autologous vascularized tissue significantly reduce the overall incidence of POPF (p = 0.04) and clinically relevant POPF grade B and C (p = 0.002). Fibrin sealant patches do not influence rates of POPF after distal pancreatectomy. None of the outcomes evaluated showed adverse results for the patch group. Patch coverage after distal pancreatectomy can reduce the rate of POPF. Patch coverage with autologous vascularized tissue but not fibrin sealant patches may be used to reduce clinically relevant POPF and postoperative morbidity in distal pancreatectomy.

  14. Intelligent food packaging - research and development

    Directory of Open Access Journals (Sweden)

    Renata Dobrucka

    2015-03-01

    Full Text Available Packaging also fosters effective marketing of the food through distribution and sale channels. It is of the utmost importance to optimize the protection of the food, a great quality and appearance - better than typical packaged foods. In recent years, intelligent packaging became very popular. Intelligent packaging is becoming more and more widely used for food products. Application of this type of solution contributes to improvement of the quality consumer life undoubtedly. Intelligent packaging refers to a package that can sense environmental changes, and in turn, informs the users about the changes. These packaging systems contain devices that are capable of sensing and providing information about the functions and properties of the packaged foods. Also, this paper will review intelligent packaging technologies and describe different types of indicators (time-temperature indicators, freshness indicators.

  15. Creative Thinking Package

    Science.gov (United States)

    Jones, Clive

    1972-01-01

    A look at the latest package from a British managment training organization, which explains and demonstrates creative thinking techniques, including brainstorming. The package, designed for groups of twelve or more, consists of tapes, visuals, and associated exercises. (Editor/JB)

  16. Fracture of Reduced-Diameter Zirconia Dental Implants Following Repeated Insertion.

    Science.gov (United States)

    Karl, Matthias; Scherg, Stefan; Grobecker-Karl, Tanja

    Achievement of high insertion torque values indicating good primary stability is a goal during dental implant placement. The objective of this study was to evaluate whether or not two-piece implants made from zirconia ceramic may be damaged as a result of torque application. A total of 10 two-piece zirconia implants were repeatedly inserted into polyurethane foam material with increasing density and decreasing osteotomy size. The insertion torque applied was measured, and implants were checked for fractures by applying the fluorescent penetrant method. Weibull probability of failure was calculated based on the recorded insertion torque values. Catastrophic failures could be seen in five of the implants from two different batches at insertion torques ranging from 46.0 to 70.5 Ncm, while the remaining implants (all belonging to one batch) survived. Weibull probability of failure seems to be low at the manufacturer-recommended maximum insertion torque of 35 Ncm. Chipping fractures at the thread tips as well as tool marks were the only otherwise observed irregularities. While high insertion torques may be desirable for immediate loading protocols, zirconia implants may fracture when manufacturer-recommended insertion torques are exceeded. Evaluating bone quality prior to implant insertion may be useful.

  17. Perspectives on the Elements of Packaging Design : A Qualitative Study on the Communication of Packaging

    OpenAIRE

    Alervall, Viktoria; Saied, Juan Sdiq

    2013-01-01

    Background: In today’s markets almost all products we buy come packaged. We use packaging to protect, contain and identify products. Furthermore if this is executed in a skillful way consumers often choose products based on packaging. The work of a designer and marketer is therefore extremely valuable when it comes to the design of a package. Problem: How are packages used to communicate marketing information? Purpose: The focus of this thesis is to identify differences and similarities of a ...

  18. 21 CFR 355.20 - Packaging conditions.

    Science.gov (United States)

    2010-04-01

    ... conditions. (a) Package size limitation. Due to the toxicity associated with fluoride active ingredients, the... (toothpastes and tooth powders) packages shall not contain more than 276 milligrams (mg) total fluorine per... packages shall not contain more than 120 mg total fluorine per package. (3) Exception. Package size...

  19. 19 CFR 191.13 - Packaging materials.

    Science.gov (United States)

    2010-04-01

    ... 19 Customs Duties 2 2010-04-01 2010-04-01 false Packaging materials. 191.13 Section 191.13 Customs... (CONTINUED) DRAWBACK General Provisions § 191.13 Packaging materials. (a) Imported packaging material... packaging material when used to package or repackage merchandise or articles exported or destroyed pursuant...

  20. Warpage of QFN Package in Post Mold Cure Process of integrated circuit packaging

    Science.gov (United States)

    Sriwithoon, Nattha; Ugsornrat, Kessararat; Srisuwitthanon, Warayoot; Thonglor, Panakamon

    2017-09-01

    This research studied about warpage of QFN package in post mold cure process of integrated circuit (IC) packages using pre-plated (PPF) leadframe. For IC package, epoxy molding compound (EMC) are molded by cross linking of compound stiffness but incomplete crosslinked network and leading the fully cured thermoset by post mold cure (PMC) process. The cure temperature of PMC can change microstructure of EMC in term of stress inside the package and effect to warpage of the package due to coefficient of thermal expansion (CTE) between EMC and leadframe. In experiment, cure temperatures were varied to check the effect of internal stress due to different cure temperature after completed post mold cure for TDFN 2×3 8L. The cure temperature were varied with 180 °C, 170 °C, 160 °C, and 150°C with cure time 4 and 6 hours, respectively. For analysis, the TDFN 2×3 8L packages were analyzed the warpage by thickness gauge and scanning acoustic microscope (SAM) after take the test samples out from the oven cure. The results confirmed that effect of different CTE between EMC and leadframe due to different cure temperature resulting to warpage of the TDFN 2×3 8L packages.

  1. CYPROS - Cybernetic Program Packages

    Directory of Open Access Journals (Sweden)

    Arne Tyssø

    1980-10-01

    Full Text Available CYPROS is an interactive program system consisting of a number of special purpose packages for simulation, identification, parameter estimation and control system design. The programming language is standard FORTRAN IV and the system is implemented on a medium size computer system (Nord-10. The system is interactive and program control is obtained by the use of numeric terminals. Output is rapidly examined by extensive use of video colour graphics. The subroutines included in the packages are designed and documented according to standardization rules given by the SCL (Scandinavian Control Library organization. This simplifies the exchange of subroutines throughout the SCL system. Also, this makes the packages attractive for implementation by industrial users. In the simulation package, different integration methods are available and it can be easily used for off-line, as well as real time, simulation problems. The identification package consists of programs for single-input/single-output and multivariablc problems. Both transfer function models and state space models can be handled. Optimal test signals can be designed. The control package consists of programs based on multivariable time domain and frequency domain methods for analysis and design. In addition, there is a package for matrix and time series manipulation. CYPROS has been applied successfully to industrial problems of various kinds, and parts of the system have already been implemented on different computers in industry. This paper will, in some detail, describe the use and the contents of the packages and some examples of application will be discussed.

  2. Characterization of integrated circuit packaging materials

    CERN Document Server

    Moore, Thomas

    1993-01-01

    Chapters in this volume address important characteristics of IC packages. Analytical techniques appropriate for IC package characterization are demonstrated through examples of the measurement of critical performance parameters and the analysis of key technological problems of IC packages. Issues are discussed which affect a variety of package types, including plastic surface-mount packages, hermetic packages, and advanced designs such as flip-chip, chip-on-board and multi-chip models.

  3. System for Packaging Planetary Samples for Return to Earth

    Science.gov (United States)

    Badescu, Mircea; Bar-Cohen, Yoseph; Backes, paul G.; Sherrit, Stewart; Bao, Xiaoqi; Scott, James S.

    2010-01-01

    A system is proposed for packaging material samples on a remote planet (especially Mars) in sealed sample tubes in preparation for later return to Earth. The sample tubes (Figure 1) would comprise (1) tubes initially having open tops and closed bottoms; (2) small, bellows-like collapsible bodies inside the tubes at their bottoms; and (3) plugs to be eventually used to close the tops of the tubes. The top inner surface of each tube would be coated with solder. The side of each plug, which would fit snugly into a tube, would feature a solder-filled ring groove. The system would include equipment for storing, manipulating, filling, and sealing the tubes. The containerization system (see Figure 2) will be organized in stations and will include: the storage station, the loading station, and the heating station. These stations can be structured in circular or linear pattern to minimize the manipulator complexity, allowing for compact design and mass efficiency. The manipulation of the sample tube between stations is done by a simple manipulator arm. The storage station contains the unloaded sample tubes and the plugs before sealing as well as the sealed sample tubes with samples after loading and sealing. The chambers at the storage station also allow for plug insertion into the sample tube. At the loading station the sample is poured or inserted into the sample tube and then the tube is topped off. At the heating station the plug is heated so the solder ring melts and seals the plug to the sample tube. The process is performed as follows: Each tube is filled or slightly overfilled with sample material and the excess sample material is wiped off the top. Then, the plug is inserted into the top section of the tube packing the sample material against the collapsible bellowslike body allowing the accommodation of the sample volume. The plug and the top of the tube are heated momentarily to melt the solder in order to seal the tube.

  4. The ZOOM minimization package

    International Nuclear Information System (INIS)

    Fischler, Mark S.; Sachs, D.

    2004-01-01

    A new object-oriented Minimization package is available for distribution in the same manner as CLHEP. This package, designed for use in HEP applications, has all the capabilities of Minuit, but is a re-write from scratch, adhering to modern C++ design principles. A primary goal of this package is extensibility in several directions, so that its capabilities can be kept fresh with as little maintenance effort as possible. This package is distinguished by the priority that was assigned to C++ design issues, and the focus on producing an extensible system that will resist becoming obsolete

  5. Packaging Concerns/Techniques for Large Devices

    Science.gov (United States)

    Sampson, Michael J.

    2009-01-01

    This slide presentation reviews packaging challenges and options for electronic parts. The presentation includes information about non-hermetic packages, space challenges for packaging and complex package variations.

  6. The efficiency and safety of fibrin sealant for reducing blood loss in primary total hip arthroplasty: A systematic review and meta-analysis.

    Science.gov (United States)

    Wang, Zhiyuan; Xiao, Lin; Guo, Hao; Zhao, Guanghui; Ma, Jianbing

    2017-01-01

    Total hip arthroplasty (THA) is associated with substantial blood loss. The objective of present systematic review and meta-analysis is to provide evidence from randomized controlled trials (RCTs) on the efficiency and safety of administration of fibrin sealant (FS) for reducing blood loss in patients undergoing primary THA. Potential relevant studies were identified from electronic databases including Medline, PubMed, Embase, ScienceDirect, web of science and Cochrane Library. Gray academic studies were also identified from the reference list of included studies. There was no language restriction. Pooling of data was carried out by using RevMan 5.1. Six randomized controlled trials (RCTs) met the inclusion criteria. Current meta-analysis indicated that there were significant differences in terms of total blood loss (MD = -153.77, 95% CI: -287.21 to -20.34, P = 0.02), postoperative hemoglobin level (MD = -0.25, 95% CI: -0.46 to -0.05, P = 0.02) and transfusion rate (RD = -0.12, 95% CI: -0.22 to -0.03, P = 0.01) between groups. No significant differences were found regarding the incidence of deep venous thrombosis (DVT) (RD = 0.00, 95% CI: -0.01to 0.01, P = 0.51) or other side effects. Administration of fibrin sealant in total hip arthroplasty may reduce total blood loss, postoperative hemoglobin decline and transfusion requirements. Moreover, no adverse effect was related to FS. Due to the limited quality of the evidence currently available, higher quality RCTs are required. Copyright © 2016 IJS Publishing Group Ltd. Published by Elsevier Ltd. All rights reserved.

  7. Packaging and transport of radioisotopes

    International Nuclear Information System (INIS)

    Taylor, C.B.G.

    1976-01-01

    The importance of radioisotope traffic is emphasized. More than a million packages are being transported each year, mostly for medical uses. The involvement of public transport services and the incidental dose to the public (which is very small) are appreciably greater than for movements connected with the nuclear fuel cycle. Modern isotope packages are described, and an outline given of the problems of a large radioisotope manufacturer who has to package many different types of product. Difficulties caused by recent uncoordinated restrictions on the use of passenger aircraft are mentioned. Some specific problems relating to radioisotope packaging are discussed. These include the crush resistance of Type A packages, the closure of steel drums, the design of secure closures for large containers, the Type A packaging of liquids, leak tightness criteria of Type B packages, and the use of 'unit load' overpacks to consign a group of individually approved packages together as a single shipment. Reference is made to recent studies of the impact of radioisotope shipments on the environment. Cost/benefit analysis is important in this field - an important public debate is only just beginning. (author)

  8. Safety Analysis Report - Packages, 9965, 9968, 9972-9975 Packages

    International Nuclear Information System (INIS)

    Van Alstine, M.N.

    1999-01-01

    This Safety Analysis Report for Packaging (SARP) documents the performance of the 9965 B, 9968 B, 9972 B(U), 9973 B(U), 9974 B(U), and 9975 B(U) packages in satisfying the regulatory safety requirements of the Code of Federal Regulations (CFR) 711 and the International Atomic Energy Agency (IAEA) Safety Series No. 6, Regulations for the Safe Transport of Radioactive Material, 1985 edition2. Results of the analysis and testing performed on the 9965 B, 9968 B, 9972 B(U), 9973 B(U), 9974 B(U), and 9975 B(U) packages are presented in this SARP, which was prepared in accordance with U.S. Department of energy (DOE) Order 5480.33 and in the format specified in the Nuclear Regulatory Commission (NRC) Regulatory Guides 7.94 and 7.10.5

  9. Safety analysis report - packages 9965, 9968, 9972-9975 packages

    International Nuclear Information System (INIS)

    Van Alstine, M.N.

    1997-10-01

    This Safety Analysis Report for Packaging (SARP) documents the performance of the 9965 B( ), 9968 B( ), 9972 B(U), 9973 B(U), 9974 B(U), and 9975 B(U) packages in satisfying the regulatory safety requirements of the Code of Federal Regulations (CFR) 10 CFR 71 and the International Atomic Energy Agency (IAEA) Safety Series No. 6, Regulations for the Safe Transport of Radioactive Material, 1985 edition. Results of the analysis and testing performed on the 9965 B(), 9968 B(), 9972 B(U), 9973 B(U), and 9975 B(U) packages are presented in this SARP, which was prepared in accordance with U.S. Department of Energy (DOE) Order 5480.3 and in the format specified in the Nuclear Regulatory Commission (NRC) Regulatory Guides 7.9 and 7.10

  10. Healthy package, healthy product? Effects of packaging design as a function of purchase setting

    NARCIS (Netherlands)

    van Rompay, Thomas Johannes Lucas; Deterink, Florien; Fenko, Anna

    2016-01-01

    Inspired by research testifying to the influence of visual packaging appearance and meaning portrayal on food evaluation, here it is argued that effects of packaging design vary depending on purchase context. Realistic packaging variants for a fictitious yoghurt brand varying in health connotation

  11. Integrated Approach to Industrial Packaging Design

    Science.gov (United States)

    Vorobeva, O.

    2017-11-01

    The article reviews studies in the field of industrial packaging design. The major factors which influence technological, ergonomic, economic and ecological features of packaging are established. The main modern trends in packaging design are defined, the principles of marketing communications and their influence on consumers’ consciousness are indicated, and the function of packaging as a transmitter of brand values is specified. Peculiarities of packaging technology and printing techniques in modern printing industry are considered. The role of designers in the stage-by-stage development of the construction, form and graphic design concept of packaging is defined. The examples of authentic packaging are given and the mention of the tetrahedron packaging history is made. At the end of the article, conclusions on the key research aspects are made.

  12. Directory of certificates of compliance for radioactive materials packages. Summary report of NRC approved packages

    International Nuclear Information System (INIS)

    1979-10-01

    This directory contains a Summary Report of NRC Approved Packages for radioactive material packages effective September 14, 1979. Purpose of this directory is to make available a convenient source of information on packagings which have been approved by the US Nuclear Regulatory Commission. To assist in identifying packaging, an index by Model Number and corresponding Certificate of Compliance number is included at the back of each volume of the directory. The Summary Report includes a listing of all users of each package design prior to the publication date of the directory

  13. Directory of certificates of compliance for radioactive materials packages. Summary report of NRC approved packages

    Energy Technology Data Exchange (ETDEWEB)

    None

    1979-10-01

    This directory contains a Summary Report of NRC Approved Packages for radioactive material packages effective September 14, 1979. Purpose of this directory is to make available a convenient source of information on packagings which have been approved by the US Nuclear Regulatory Commission. To assist in identifying packaging, an index by Model Number and corresponding Certificate of Compliance number is included at the back of each volume of the directory. The Summary Report includes a listing of all users of each package design prior to the publication date of the directory.

  14. Directory of Certificates of Compliance for Radioactive Materials Packages: Report of NRC approved packages

    International Nuclear Information System (INIS)

    1988-12-01

    This directory contains a Report of the US Nuclear Regulatory Commission's Approved Packages (Volume 1), all Certificates of Compliance (Volume 2), and a Report of NRC Approved Quality Assurance Programs (Volume 3) for Radioactive Material Packages effective October 1, 1988. The purpose of this directory is to make available a convenient source of information on packagings which have been approved by the US Nuclear Regulatory Commission. To assist in identifying packaging, an index by Model Number and corresponding Certificate of Compliance Number is included at the front of Volume 2 of the directory. A listing by packaging types is included in the back of Volume 2. An alphabetical listing by Company name is included in the back of Volume 3 for approved QA programs. The Reports include a listing of all users of each package design and approved QA programs prior to the publication date of the directory

  15. Directory of certificates of compliance for radioactive materials packages, Report of NRC approved packages

    International Nuclear Information System (INIS)

    1990-10-01

    This directory contains a Report of the US Nuclear Regulatory Commission's Approved Packages (Volume 1), Certificates of Compliance (Volume 2), and a Report of NRC Approved Quality Assurance Programs (Volume 3) for Radioactive Materials Packages effective October 1, 1990. The purpose of this directory is to make available a convenient source of information on packagings which have been approved by the US Nuclear Regulatory Commission. To assist in identifying packaging, an index by Model Number and corresponding Certificate of Compliance Number is included at the front of Volume 2 of the directory. A listing by packaging types is included in the back of Volume 2. An alphabetical listing by Company name is included in the back of Volume 3 for approved QA programs. The Reports include a listing of all users of each package design and approved QA programs prior to the publication date of the directory

  16. Chronic insertional Achilles tendinopathy: surgical outcomes

    OpenAIRE

    Oshri, Yael; Palmanovich, Ezequiel; Brin, Yaron Shagra; Karpf, Ronen; Massarwe, Sabri; Kish, Benny; Nyska, Meir

    2012-01-01

    Background and objective: insertional Achilles tendinopathy is a common condition among athletes and joggers. One fifth of the injuries involves the insertion of the tendon. The etiology is either due to mechanical overuse related to sports activity, or a systemic inflammatory disease. The clinical appearance includes pain and movement restriction. The primary treatment is conservative. The surgery referred to in this study (Calcaneal Osteotomy) is performed by decompression of the posterior ...

  17. Identifying transposon insertions and their effects from RNA-sequencing data.

    Science.gov (United States)

    de Ruiter, Julian R; Kas, Sjors M; Schut, Eva; Adams, David J; Koudijs, Marco J; Wessels, Lodewyk F A; Jonkers, Jos

    2017-07-07

    Insertional mutagenesis using engineered transposons is a potent forward genetic screening technique used to identify cancer genes in mouse model systems. In the analysis of these screens, transposon insertion sites are typically identified by targeted DNA-sequencing and subsequently assigned to predicted target genes using heuristics. As such, these approaches provide no direct evidence that insertions actually affect their predicted targets or how transcripts of these genes are affected. To address this, we developed IM-Fusion, an approach that identifies insertion sites from gene-transposon fusions in standard single- and paired-end RNA-sequencing data. We demonstrate IM-Fusion on two separate transposon screens of 123 mammary tumors and 20 B-cell acute lymphoblastic leukemias, respectively. We show that IM-Fusion accurately identifies transposon insertions and their true target genes. Furthermore, by combining the identified insertion sites with expression quantification, we show that we can determine the effect of a transposon insertion on its target gene(s) and prioritize insertions that have a significant effect on expression. We expect that IM-Fusion will significantly enhance the accuracy of cancer gene discovery in forward genetic screens and provide initial insight into the biological effects of insertions on candidate cancer genes. © The Author(s) 2017. Published by Oxford University Press on behalf of Nucleic Acids Research.

  18. Safety analysis report for packages: packaging of fissile and other radioactive materials. Final report

    International Nuclear Information System (INIS)

    Chalfant, G.G.

    1984-01-01

    The 9965, 9966, 9967, and 9968 packages are designed for surface shipment of fissile and other radioactive materials where a high degree of containment (either single or double) is required. Provisions are made to add shielding material to the packaging as required. The package was physically tested to demonstrate that it meets the criteria specified in USDOE Order No. 5480.1, chapter III, dated 5/1/81, which invokes Title 10, Code of Federal Regulations, Part 71 (10 CFR 71), Packing and Transportation of Radioactive Material, and Title 49, Code of Federal Regulations, Part 100-179, Transportation. By restricting the maximum normal operating pressure of the packages to less than 7 kg/cm 2 (gauge) (99 to 54 psig), the packages will comply with Type B(U) regulations of the International Atomic Energy Agency (IAEA) in its Regulations for the Safe Transport of Radioactive Materials, Safety Series No. 6, 1973 Revised Edition, and may be used for export and import shipments. These packages have been assessed for transport of up to 14.5 kilograms of uranium, excluding uranium-233, or 4.4 kilograms of plutonium metal, oxides, or scrap having a maximum radioactive decay energy of 30 watts. Specific maximum package contents are given. This quantity and the configuration of uranium or plutonium metal cannot be made critical by any combination of hydrogeneous reflection and moderation regardless of the condition of the package. For a uranium-233 shipment, a separate criticality evaluation for the specific package is required

  19. The supermodule insertion tool of the CMS electromagnetic calorimeter and the first trial insertion of a supermodule.

    CERN Multimedia

    Maximilien Brice

    2006-01-01

    The first trial insertion of a complete Electromagnetic Calorimeter (ECAL) "supermodule" (1700 lead-tungstate crystals, with support structures, light detectors (avalanche photodiodes), readout electronics and cooling system) was performed on 1st March. This delicate operation - sliding a 2-tonne 3m-long object onto support rails (in real life these are attached to the barrel hadron calorimeter (HCAL)) - made use of a custom designed "squirrel cage". The rotatable squirrel cage allows the insertion of any supermodule into any of the 18 positions, including very fine (sub-mm) adjustments. The first supermodule will be inserted into the real HCAL later this month in preparation for the "magnet test and cosmic-ray challenge" (MTCC). In the first image the supermodule is in the centre and the alignment disks are highlighted by the flash.

  20. Ensuring socially responsible packaging design

    DEFF Research Database (Denmark)

    Geert Jensen, Birgitte

    Most consumers have experienced occasional problems with opening packaging. Tomato sauce from the tinned mackerel splattered all over the kitchen counter, the unrelenting pickle jar lid, and the package of sliced ham that cannot be opened without a knife or a pair of scissors. The research project...... "User‐friendly Packaging" aims to create a platform for developing more user‐friendly packaging. One intended outcome of the project is a guideline that industry can use in development efforts. The project also points the way for more extended collaboration between companies and design researchers. How...... can design research help industry in packaging innovation?...

  1. Packaging based on polymeric materials

    Directory of Open Access Journals (Sweden)

    Jovanović Slobodan M.

    2005-01-01

    Full Text Available In the past two years the consumption of common in the developed countries world wide (high tonnage polymers for packaging has approached a value of 50 wt.%. In the same period more than 50% of the packaging units on the world market were made of polymeric materials despite the fact that polymeric materials present 17 wt.% of all packaging materials. The basic properties of polymeric materials and their environmental and economical advantages, providing them such a position among packaging materials, are presented in this article. Recycling methods, as well as the development trends of polymeric packaging materials are also presented.

  2. Advanced flip chip packaging

    CERN Document Server

    Lai, Yi-Shao; Wong, CP

    2013-01-01

    Advanced Flip Chip Packaging presents past, present and future advances and trends in areas such as substrate technology, material development, and assembly processes. Flip chip packaging is now in widespread use in computing, communications, consumer and automotive electronics, and the demand for flip chip technology is continuing to grow in order to meet the need for products that offer better performance, are smaller, and are environmentally sustainable. This book also: Offers broad-ranging chapters with a focus on IC-package-system integration Provides viewpoints from leading industry executives and experts Details state-of-the-art achievements in process technologies and scientific research Presents a clear development history and touches on trends in the industry while also discussing up-to-date technology information Advanced Flip Chip Packaging is an ideal book for engineers, researchers, and graduate students interested in the field of flip chip packaging.

  3. Challenges in the Packaging of MEMS

    Energy Technology Data Exchange (ETDEWEB)

    Malshe, A.P.; Singh, S.B.; Eaton, W.P.; O' Neal, C.; Brown, W.D.; Miller, W.M.

    1999-03-26

    The packaging of Micro-Electro-Mechanical Systems (MEMS) is a field of great importance to anyone using or manufacturing sensors, consumer products, or military applications. Currently much work has been done in the design and fabrication of MEMS devices but insufficient research and few publications have been completed on the packaging of these devices. This is despite the fact that packaging is a very large percentage of the total cost of MEMS devices. The main difference between IC packaging and MEMS packaging is that MEMS packaging is almost always application specific and greatly affected by its environment and packaging techniques such as die handling, die attach processes, and lid sealing. Many of these aspects are directly related to the materials used in the packaging processes. MEMS devices that are functional in wafer form can be rendered inoperable after packaging. MEMS dies must be handled only from the chip sides so features on the top surface are not damaged. This eliminates most current die pick-and-place fixtures. Die attach materials are key to MEMS packaging. Using hard die attach solders can create high stresses in the MEMS devices, which can affect their operation greatly. Low-stress epoxies can be high-outgassing, which can also affect device performance. Also, a low modulus die attach can allow the die to move during ultrasonic wirebonding resulting to low wirebond strength. Another source of residual stress is the lid sealing process. Most MEMS based sensors and devices require a hermetically sealed package. This can be done by parallel seam welding the package lid, but at the cost of further induced stress on the die. Another issue of MEMS packaging is the media compatibility of the packaged device. MEMS unlike ICS often interface with their environment, which could be high pressure or corrosive. The main conclusion we can draw about MEMS packaging is that the package affects the performance and reliability of the MEMS devices. There is a

  4. CH Packaging Program Guidance

    International Nuclear Information System (INIS)

    2006-01-01

    The purpose of this document is to provide the technical requirements for preparation for use, operation, inspection, and maintenance of a Transuranic Package Transporter Model II (TRUPACT-II), a HalfPACT shipping package, and directly related components. This document complies with the minimum requirements as specified in the TRUPACT-II Safety Analysis Report for Packaging (SARP), HalfPACT SARP, and U.S. Nuclear Regulatory Commission (NRC) Certificates of Compliance (C of C) 9218 and 9279, respectively. In the event of a conflict between this document and the SARP or C of C, the C of C shall govern. The C of Cs state: 'each package must be prepared for shipment and operated in accordance with the procedures described in Chapter 7.0, Operating Procedures, of the application.' They further state: 'each package must be tested and maintained in accordance with the procedures described in Chapter 8.0, Acceptance Tests and Maintenance Program of the Application.' Chapter 9.0 of the SARP charges the U.S. Department of Energy (DOE) or the Waste Isolation Pilot Plant| (WIPP) management and operating (M and O) contractor with assuring packaging is used in accordance with the requirements of the C of C. Because the packaging is NRC-approved, users need to be familiar with Title 10 Code of Federal Regulations(CFR) 71.8. Any time a user suspects or has indications that the conditions of approval in the C of C were not met, the Carlsbad Field Office (CBFO) shall be notified immediately. The CBFO will evaluate the issue and notify the NRC if required.In accordance with 10 CFR Part 71, certificate holders, packaging users, and contractors or subcontractors who use, design, fabricate, test, maintain, or modify the packaging shall post copies of (1) 10 CFR Part 21 regulations, (2) Section 206 of the Energy Reorganization Act of 1974, and (3) NRC Form 3, Notice to Employees. These documents must be posted in a conspicuous location where the activities subject to these regulations

  5. CH Packaging Program Guidance

    International Nuclear Information System (INIS)

    2007-01-01

    The purpose of this document is to provide the technical requirements for preparation for use, operation, inspection, and maintenance of a Transuranic Package Transporter Model II (TRUPACT-II), a HalfPACT shipping package, and directly related components. This document complies with the minimum requirements as specified in the TRUPACT-II Safety Analysis Report for Packaging (SARP), HalfPACT SARP, and U.S. Nuclear Regulatory Commission (NRC) Certificates of Compliance (C of C) 9218 and 9279, respectively. In the event of a conflict between this document and the SARP or C of C, the C of C shall govern. The C of Cs state: 'each package must be prepared for shipment and operated in accordance with the procedures described in Chapter 7.0, Operating Procedures, of the application.' They further state: 'each package must be tested and maintained in accordance with the procedures described in Chapter 8.0, Acceptance Tests and Maintenance Program of the Application.' Chapter 9.0 of the SARP charges the U.S. Department of Energy (DOE) or the Waste Isolation Pilot Plant (WIPP) management and operating (M and O) contractor with assuring packaging is used in accordance with the requirements of the C of C. Because the packaging is NRC-approved, users need to be familiar with Title 10 Code of Federal Regulations (CFR) 71.8. Any time a user suspects or has indications that the conditions of approval in the C of C were not met, the Carlsbad Field Office (CBFO) shall be notified immediately. The CBFO will evaluate the issue and notify the NRC if required.In accordance with 10 CFR Part 71, certificate holders, packaging users, and contractors or subcontractors who use, design, fabricate, test, maintain, or modify the packaging shall post copies of (1) 10 CFR Part 21 regulations, (2) Section 206 of the Energy Reorganization Act of 1974, and (3) NRC Form 3, Notice to Employees. These documents must be posted in a conspicuous location where the activities subject to these regulations

  6. LOFT voltage insertion calibaration program

    International Nuclear Information System (INIS)

    Tillitt, D.N.; Miyasaki, F.S.

    1975-08-01

    The Loss-of-Fluid Test (LOFT) Facility is an experimental facility built around a ''scaled'' version of a large pressurized water reactor (LPWR). Part of this facility is the Data Acquisition and Visual Display System (DAVDS) as defined by the LOFT System Design Document SDD 1.4.2C. The DAVDS has a 702 data channel recording capability of which 548 are recorded digitally. The DAVDS also contains a Voltage Insertion Calibration Subsystem used to inject precise and known voltage steps into the recording systems. The computer program that controls the Voltage Insertion Calibration Subsystem is presented. 7 references. (auth)

  7. User friendly packaging

    DEFF Research Database (Denmark)

    Geert Jensen, Birgitte

    2010-01-01

    Most consumers have experienced occasional problems with opening packaging. Tomato sauce from the tinned mackerel splattered all over the kitchen counter, the unrelenting pickle jar lid, and the package of sliced ham that cannot be opened without a knife or a pair of scissors. The research project...

  8. Scilab software package for the study of dynamical systems

    Science.gov (United States)

    Bordeianu, C. C.; Beşliu, C.; Jipa, Al.; Felea, D.; Grossu, I. V.

    2008-05-01

    This work presents a new software package for the study of chaotic flows and maps. The codes were written using Scilab, a software package for numerical computations providing a powerful open computing environment for engineering and scientific applications. It was found that Scilab provides various functions for ordinary differential equation solving, Fast Fourier Transform, autocorrelation, and excellent 2D and 3D graphical capabilities. The chaotic behaviors of the nonlinear dynamics systems were analyzed using phase-space maps, autocorrelation functions, power spectra, Lyapunov exponents and Kolmogorov-Sinai entropy. Various well known examples are implemented, with the capability of the users inserting their own ODE. Program summaryProgram title: Chaos Catalogue identifier: AEAP_v1_0 Program summary URL:http://cpc.cs.qub.ac.uk/summaries/AEAP_v1_0.html Program obtainable from: CPC Program Library, Queen's University, Belfast, N. Ireland Licensing provisions: Standard CPC licence, http://cpc.cs.qub.ac.uk/licence/licence.html No. of lines in distributed program, including test data, etc.: 885 No. of bytes in distributed program, including test data, etc.: 5925 Distribution format: tar.gz Programming language: Scilab 3.1.1 Computer: PC-compatible running Scilab on MS Windows or Linux Operating system: Windows XP, Linux RAM: below 100 Megabytes Classification: 6.2 Nature of problem: Any physical model containing linear or nonlinear ordinary differential equations (ODE). Solution method: Numerical solving of ordinary differential equations. The chaotic behavior of the nonlinear dynamical system is analyzed using Poincaré sections, phase-space maps, autocorrelation functions, power spectra, Lyapunov exponents and Kolmogorov-Sinai entropies. Restrictions: The package routines are normally able to handle ODE systems of high orders (up to order twelve and possibly higher), depending on the nature of the problem. Running time: 10 to 20 seconds for problems that do not

  9. Packaging of control system software

    International Nuclear Information System (INIS)

    Zagar, K.; Kobal, M.; Saje, N.; Zagar, A.; Sabjan, R.; Di Maio, F.; Stepanov, D.

    2012-01-01

    Control system software consists of several parts - the core of the control system, drivers for integration of devices, configuration for user interfaces, alarm system, etc. Once the software is developed and configured, it must be installed to computers where it runs. Usually, it is installed on an operating system whose services it needs, and also in some cases dynamically links with the libraries it provides. Operating system can be quite complex itself - for example, a typical Linux distribution consists of several thousand packages. To manage this complexity, we have decided to rely on Red Hat Package Management system (RPM) to package control system software, and also ensure it is properly installed (i.e., that dependencies are also installed, and that scripts are run after installation if any additional actions need to be performed). As dozens of RPM packages need to be prepared, we are reducing the amount of effort and improving consistency between packages through a Maven-based infrastructure that assists in packaging (e.g., automated generation of RPM SPEC files, including automated identification of dependencies). So far, we have used it to package EPICS, Control System Studio (CSS) and several device drivers. We perform extensive testing on Red Hat Enterprise Linux 5.5, but we have also verified that packaging works on CentOS and Scientific Linux. In this article, we describe in greater detail the systematic system of packaging we are using, and its particular application for the ITER CODAC Core System. (authors)

  10. Insertion compounds of transition-metal and uranium oxides

    International Nuclear Information System (INIS)

    Chippindale, A.M.; Dickens, P.G.; Powell, A.V.

    1991-01-01

    Several transition-metal and actinide oxides, in which the metal occurs in a high oxidation state, have open covalent structures and are capable of incorporating alkali and other electropositive metals under mild conditions to form insertion compounds A x MO n . These are solids which have several features in common: Over a range of compositions, A x MO n exists as one or more stable or metastable phases in which the structure of the parent oxide MO n is largely retained and the insertion element A is accommodated interstitially. Insertion is accompanied by a redox process A=A i . + e - M in which M is reduced and the electronic properties of the parent oxide change to those typical of a mixed-valence compound. The insertion process xA + MO n = A x MO n can be reversed, at least to some extent, by chemical or electrochemical reaction, with retention of structure (topotactic reaction). This review concentrates on methods of synthesis, characterisation, crystal structure and thermochemistry of these insertion compounds. It updates and extends previous work. (author)

  11. Treatment of hilar cholangiocarcinoma with inserting biliary double stents

    International Nuclear Information System (INIS)

    Jia Guangzhi; Zhang Zidong; Wang Xuejing; Yin Hua; Li Jianming

    2004-01-01

    Objective: To investigate the inserting technique of biliary double stents in treating hilar cholangiocarcinoma. Methods: 6 patients with hilar cholangiocarcinoma (Bismuth IV) were treated by percutaneous transhepatic insertion of biliary stents. Double stents were inserted in each patient. Different inserting methods were adopted according to the branch angles formed by left and right hepatic ducts. Results: The jaundice of all patients alleviated or disappeared obviously after stent implantation. The average difference between post-and pre-operation in the serum total bilirubin level was (104 ± 29) μmol/L (P<0.01). Stent obstruction was found in 2 cases after 4 and 6 months respectively. Conclusion: Double stents implantation is effective for the treatment of hilar cholangiocarcinoma. Beware of the angulation between main hepatic duct and adopting different inserting methods. (authors)

  12. Sensory impacts of food-packaging interactions.

    Science.gov (United States)

    Duncan, Susan E; Webster, Janet B

    2009-01-01

    Sensory changes in food products result from intentional or unintentional interactions with packaging materials and from failure of materials to protect product integrity or quality. Resolving sensory issues related to plastic food packaging involves knowledge provided by sensory scientists, materials scientists, packaging manufacturers, food processors, and consumers. Effective communication among scientists and engineers from different disciplines and industries can help scientists understand package-product interactions. Very limited published literature describes sensory perceptions associated with food-package interactions. This article discusses sensory impacts, with emphasis on oxidation reactions, associated with the interaction of food and materials, including taints, scalping, changes in food quality as a function of packaging, and examples of material innovations for smart packaging that can improve sensory quality of foods and beverages. Sensory evaluation is an important tool for improved package selection and development of new materials.

  13. Plutonium stabilization and packaging system

    International Nuclear Information System (INIS)

    1996-01-01

    This document describes the functional design of the Plutonium Stabilization and Packaging System (Pu SPS). The objective of this system is to stabilize and package plutonium metals and oxides of greater than 50% wt, as well as other selected isotopes, in accordance with the requirements of the DOE standard for safe storage of these materials for 50 years. This system will support completion of stabilization and packaging campaigns of the inventory at a number of affected sites before the year 2002. The package will be standard for all sites and will provide a minimum of two uncontaminated, organics free confinement barriers for the packaged material

  14. RH Packaging Operations Manual

    International Nuclear Information System (INIS)

    Washington TRU Solutions LLC

    2003-01-01

    This procedure provides operating instructions for the RH-TRU 72-B Road Cask, Waste Shipping Package. In this document, ''Packaging'' refers to the assembly of components necessary to ensure compliance with the packaging requirements (not loaded with a payload). ''Package'' refers to a Type B packaging that, with its radioactive contents, is designed to retain the integrity of its containment and shielding when subject to the normal conditions of transport and hypothetical accident test conditions set forth in 10 CFR Part 71. Loading of the RH 72-B cask can be done two ways, on the RH cask trailer in the vertical position or by removing the cask from the trailer and loading it in a facility designed for remote-handling (RH). Before loading the 72-B cask, loading procedures and changes to the loading procedures for the 72-B cask must be sent to CBFO at sitedocuments at wipp.ws for approval

  15. MARS software package status

    International Nuclear Information System (INIS)

    Azhgirej, I.L.; Talanov, V.V.

    2000-01-01

    The MARS software package is intended for simulating the nuclear-electromagnetic cascades and the secondary neutrons and muons transport in the heterogeneous medium of arbitrary complexity in the magnetic fields presence. The inclusive approach to describing the particle production in the nuclear and electromagnetic interactions and by the unstable particles decay is realized in the package. The MARS software package was actively applied for solving various radiation physical problems [ru

  16. CH Packaging Program Guidance

    International Nuclear Information System (INIS)

    Washington TRU Solutions LLC

    2003-01-01

    The purpose of this document is to provide the technical requirements for preparation for use, operation, inspection, and maintenance of a Transuranic Package Transporter Model II (TRUPACT-II), a HalfPACT shipping package, and directly related components. This document complies with the minimum requirements as specified in the TRUPACT-II Safety Analysis Report for Packaging (SARP), HalfPACT SARP, and Nuclear Regulatory Commission (NRC) Certificates of Compliance (C of C) 9218 and 9279, respectively. In the event of a conflict between this document and the SARP or C of C, the C of C shall govern. The C of Cs state: ''each package must be prepared for shipment and operated in accordance with the procedures described in Chapter 7.0, Operating Procedures, of the application.'' They further state: ''each package must be tested and maintained in accordance with the procedures described in Chapter 8.0, Acceptance Tests and Maintenance Program of the Application.'' Chapter 9.0 of the SARP charges the WIPP management and operating (M and O) contractor with assuring packaging is used in accordance with the requirements of the C of C. Because the packaging is NRC-approved, users need to be familiar with 10 CFR 71.11. Any time a user suspects or has indications that the conditions of approval in the C of C were not met, the Carlsbad Field Office (CBFO) shall be notified immediately. CBFO will evaluate the issue and notify the NRC if required. This document provides the instructions to be followed to operate, maintain, and test the TRUPACT-II and HalfPACT packaging. The intent of these instructions is to standardize operations. All users will follow these instructions or equivalent instructions that assure operations are safe and meet the requirements of the SARPs

  17. CH Packaging Program Guidance

    International Nuclear Information System (INIS)

    Washington TRU Solutions LLC

    2002-01-01

    The purpose of this document is to provide the technical requirements for preparation for use, operation, inspection, and maintenance of a Transuranic Package Transporter Model II (TRUPACT-II), a HalfPACT Shipping Package, and directly related components. This document complies with the minimum requirements as specified in TRUPACT-II Safety Analysis Report for Packaging (SARP), HalfPACT SARP, and Nuclear Regulatory Commission (NRC) Certificates of Compliance (C of C) 9218 and 9279, respectively. In the event there is a conflict between this document and the SARP or C of C, the SARP and/or C of C shall govern. C of Cs state: ''each package must be prepared for shipment and operated in accordance with the procedures described in Chapter 7.0, Operating Procedures, of the application.'' They further state: ''each package must be tested and maintained in accordance with the procedures described in Chapter 8.0, Acceptance Tests and Maintenance Program of the Application.'' Chapter 9.0 of the SAR P charges the WIPP Management and Operation (M and O) contractor with assuring packaging is used in accordance with the requirements of the C of C. Because the packaging is NRC-approved, users need to be familiar with 10 CFR 71.11. Any time a user suspects or has indications that the conditions of approval in the C of C were not met, the Carlsbad Field Office (CBFO) shall be notified immediately. CBFO will evaluate the issue and notify the NRC if required. This document details the instructions to be followed to operate, maintain, and test the TRUPACT-II and HalfPACT packaging. The intent of these instructions is to standardize these operations. All users will follow these instructions or equivalent instructions that assure operations are safe and meet the requirements of the SARPs

  18. A new specifically designed forceps for chest drain insertion.

    LENUS (Irish Health Repository)

    Andrews, Emmet

    2012-02-03

    Insertion of a chest drain can be associated with serious complications. It is recommended that the drain is inserted with blunt dissection through the chest wall but there is no specific instrument to aid this task. We describe a new reusable forceps that has been designed specifically to facilitate the insertion of chest drains.A feasibility study of its use in patients who required a chest drain as part of elective cardiothoracic operations was undertaken. The primary end-point was successful and accurate placement of the drain. The operators also completed a questionnaire rating defined aspects of the procedure. The new instrument was used to insert the chest drain in 30 patients (19 male, 11 female; median age 61.5 years (range 16-81 years)). The drain was inserted successfully without the trocar in all cases and there were no complications. Use of the instrument rated as significantly easier relative to experience of previous techniques in all specified aspects. The new device can be used to insert intercostal chest drains safely and efficiently without using the trocar or any other instrument.

  19. Methanol Formation via Oxygen Insertion Chemistry in Ices

    Science.gov (United States)

    Bergner, Jennifer B.; Öberg, Karin I.; Rajappan, Mahesh

    2017-08-01

    We present experimental constraints on the insertion of oxygen atoms into methane to form methanol in astrophysical ice analogs. In gas-phase and theoretical studies this process has previously been demonstrated to have a very low or nonexistent energy barrier, but the energetics and mechanisms have not yet been characterized in the solid state. We use a deuterium UV lamp filtered by a sapphire window to selectively dissociate O2 within a mixture of O2:CH4 and observe efficient production of CH3OH via O(1D) insertion. CH3OH growth curves are fit with a kinetic model, and we observe no temperature dependence of the reaction rate constant at temperatures below the oxygen desorption temperature of 25 K. Through an analysis of side products we determine the branching ratio of ice-phase oxygen insertion into CH4: ˜65% of insertions lead to CH3OH, with the remainder leading instead to H2CO formation. There is no evidence for CH3 or OH radical formation, indicating that the fragmentation is not an important channel and that insertions typically lead to increased chemical complexity. CH3OH formation from O2 and CH4 diluted in a CO-dominated ice similarly shows no temperature dependence, consistent with expectations that insertion proceeds with a small or nonexistent barrier. Oxygen insertion chemistry in ices should therefore be efficient under low-temperature ISM-like conditions and could provide an important channel to complex organic molecule formation on grain surfaces in cold interstellar regions such as cloud cores and protoplanetary disk midplanes.

  20. Methanol Formation via Oxygen Insertion Chemistry in Ices

    Energy Technology Data Exchange (ETDEWEB)

    Bergner, Jennifer B. [Harvard University Department of Chemistry and Chemical Biology, 10 Oxford Street, Cambridge, MA 02138 (United States); Öberg, Karin I.; Rajappan, Mahesh [Harvard-Smithsonian Center for Astrophysics, 60 Garden Street, Cambridge, MA 02138 (United States)

    2017-08-10

    We present experimental constraints on the insertion of oxygen atoms into methane to form methanol in astrophysical ice analogs. In gas-phase and theoretical studies this process has previously been demonstrated to have a very low or nonexistent energy barrier, but the energetics and mechanisms have not yet been characterized in the solid state. We use a deuterium UV lamp filtered by a sapphire window to selectively dissociate O{sub 2} within a mixture of O{sub 2}:CH{sub 4} and observe efficient production of CH{sub 3}OH via O({sup 1}D) insertion. CH{sub 3}OH growth curves are fit with a kinetic model, and we observe no temperature dependence of the reaction rate constant at temperatures below the oxygen desorption temperature of 25 K. Through an analysis of side products we determine the branching ratio of ice-phase oxygen insertion into CH{sub 4}: ∼65% of insertions lead to CH{sub 3}OH, with the remainder leading instead to H{sub 2}CO formation. There is no evidence for CH{sub 3} or OH radical formation, indicating that the fragmentation is not an important channel and that insertions typically lead to increased chemical complexity. CH{sub 3}OH formation from O{sub 2} and CH{sub 4} diluted in a CO-dominated ice similarly shows no temperature dependence, consistent with expectations that insertion proceeds with a small or nonexistent barrier. Oxygen insertion chemistry in ices should therefore be efficient under low-temperature ISM-like conditions and could provide an important channel to complex organic molecule formation on grain surfaces in cold interstellar regions such as cloud cores and protoplanetary disk midplanes.

  1. Consumer response to packaging design

    NARCIS (Netherlands)

    Steenis, Nigel D.; Herpen, van Erica; Lans, van der Ivo A.; Ligthart, Tom N.; Trijp, van Hans C.M.

    2017-01-01

    Building on theories of cue utilization, this paper investigates whether and how packaging sustainability influences consumer perceptions, inferences and attitudes towards packaged products. A framework is tested in an empirical study among 249 students using soup products varying in packaging

  2. Natural biopolimers in organic food packaging

    Science.gov (United States)

    Wieczynska, Justyna; Cavoski, Ivana; Chami, Ziad Al; Mondelli, Donato; Di Donato, Paola; Di Terlizzi, Biagio

    2014-05-01

    Concerns on environmental and waste problems caused by use of non-biodegradable and non-renewable based plastic packaging have caused an increase interest in developing biodegradable packaging using renewable natural biopolymers. Recently, different types of biopolymers like starch, cellulose, chitosan, casein, whey protein, collagen, egg white, soybean protein, corn zein, gelatin and wheat gluten have attracted considerable attention as potential food packaging materials. Recyclable or biodegradable packaging material in organic processing standards is preferable where possible but specific principles of packaging are not precisely defined and standards have to be assessed. There is evidence that consumers of organic products have specific expectations not only with respect to quality characteristics of processed food but also in social and environmental aspects of food production. Growing consumer sophistication is leading to a proliferation in food eco-label like carbon footprint. Biopolymers based packaging for organic products can help to create a green industry. Moreover, biopolymers can be appropriate materials for the development of an active surfaces designed to deliver incorporated natural antimicrobials into environment surrounding packaged food. Active packaging is an innovative mode of packaging in which the product and the environment interact to prolong shelf life or enhance safety or sensory properties, while maintaining the quality of the product. The work will discuss the various techniques that have been used for development of an active antimicrobial biodegradable packaging materials focusing on a recent findings in research studies. With the current focus on exploring a new generation of biopolymer-based food packaging materials with possible applications in organic food packaging. Keywords: organic food, active packaging, biopolymers , green technology

  3. Lithium Insertion In Silicon Nanowires: An ab Initio Study

    KAUST Repository

    Zhang, Qianfan

    2010-09-08

    The ultrahigh specific lithium ion storage capacity of Si nanowires (SiNWs) has been demonstrated recently and has opened up exciting opportunities for energy storage. However, a systematic theoretical study on lithium insertion in SiNWs remains a challenge, and as a result, understanding of the fundamental interaction and microscopic dynamics during lithium insertion is still lacking. This paper focuses on the study of single Li atom insertion into SiNWs with different sizes and axis orientations by using full ab initio calculations. We show that the binding energy of interstitial Li increases as the SiNW diameter grows. The binding energies at different insertion sites, which can be classified as surface, intermediate, and core sites, are quite different. We find that surface sites are energetically the most favorable insertion positions and that intermediate sites are the most unfavorable insertion positions. Compared with the other growth directions, the [110] SiNWs with different diameters always present the highest binding energies on various insertion locations, which indicates that [110] SiNWs are more favorable by Li doping. Furthermore, we study Li diffusion inside SiNWs. The results show that the Li surface diffusion has a much higher chance to occur than the surface to core diffusion, which is consistent with the experimental observation that the Li insertion in SiNWs is layer by layer from surface to inner region. After overcoming a large barrier crossing surface-to-intermediate region, the diffusion toward center has a higher possibility to occur than the inverse process. © 2010 American Chemical Society.

  4. Physical and chemical characteristics of cashew nut flour stored and packaged with different packages

    Directory of Open Access Journals (Sweden)

    Bruna Carolina GADANI

    Full Text Available Abstract The aim of this study was to evaluate the physical and chemical changes in cashew nut flour under different packaging and storage conditions. The flour samples were characterized according to their chemical composition, packaged in polystyrene trays associated with covering chloride polyvinyl (PVC, plastic pot of polyethylene terephthalate (PET, plastic packaging polyethylene (POL and without coating polystyrene trays (CON. All packages were stored for 225 days, evaluating every 45 days the moisture content of the flour as well as extracting their oil by the cold method for characterization on the following indexes: acidity, saponification, iodine, peroxide and refraction. There was slight and gradual increase in the moisture content from the 45th to the 225th day, especially for products packaged in PVC and without coating polystyrene trays (CON. The oil saponification indexes showed gradual decrease during storage, especially in flour without packaging (CON. There was a gradual increase in the iodine index until the 135th day, followed by decay. The acidity and peroxide indexes increased along with the storage time. However packages with lower oxygen and moisture permeability, such as PET and POL, minimized such changes, being therefore the most suitable for long-term storage.

  5. CH Packaging Program Guidance

    International Nuclear Information System (INIS)

    2008-01-01

    The purpose of this document is to provide the technical requirements for preparation for use, operation, inspection, and maintenance of a Transuranic Package Transporter Model II (TRUPACT-II), a HalfPACT shipping package, and directly related components. This document complies with the minimum requirements as specified in the TRUPACT-II Safety Analysis Report for Packaging (SARP), HalfPACT SARP, and U.S. Nuclear Regulatory Commission (NRC) Certificates of Compliance (C of C) 9218 and 9279, respectively. In the event of a conflict between this document and the SARP or C of C, the C of C shall govern. The C of Cs state: 'each package must be prepared for shipment and operated in accordance with the procedures described in Chapter 7.0, Operating Procedures, of the pplication.' They further state: 'each package must be tested and maintained in accordance with the procedures described in Chapter 8.0, Acceptance Tests and Maintenance Program of the Application.' Chapter 9.0 of the SARP charges the U.S. Department of Energy (DOE) or the Waste Isolation Pilot Plant (WIPP) management and operating (M and O) contractor with assuring packaging is used in accordance with the requirements of the C of C. Because the packaging is NRC-approved, users need to be familiar with Title 10 Code of Federal Regulations (CFR) 71.8. Any time a user suspects or has indications that the conditions of approval in the C of C were not met, the Carlsbad Field Office (CBFO) shall be notified immediately. The CBFO will evaluate the issue and notify the NRC if required. In accordance with 10 CFR Part 71, certificate holders, packaging users, and contractors or subcontractors who use, design, fabricate, test, maintain, or modify the packaging shall post copies of (1) 10 CFR Part 21 regulations, (2) Section 206 of the Energy Reorganization Act of 1974, and (3) NRC Form 3, Notice to Employees. These documents must be posted in a conspicuous location where the activities subject to these regulations

  6. CH Packaging Program Guidance

    International Nuclear Information System (INIS)

    2009-01-01

    The purpose of this document is to provide the technical requirements for preparation for use, operation, inspection, and maintenance of a Transuranic Package Transporter Model II (TRUPACT-II), a HalfPACT shipping package, and directly related components. This document complies with the minimum requirements as specified in the TRUPACT-II Safety Analysis Report for Packaging (SARP), HalfPACT SARP, and U.S. Nuclear Regulatory Commission (NRC) Certificates of Compliance (C of C) 9218 and 9279, respectively. In the event of a conflict between this document and the SARP or C of C, the C of C shall govern. The C of Cs state: 'each package must be prepared for shipment and operated in accordance with the procedures described in Chapter 7.0, Operating Procedures, of the application.' They further state: 'each package must be tested and maintained in accordance with the procedures described in Chapter 8.0, Acceptance Tests and Maintenance Program of the Application.' Chapter 9.0 of the SARP charges the U.S. Department of Energy (DOE) or the Waste Isolation Pilot Plant (WIPP) management and operating (M and O) contractor with assuring packaging is used in accordance with the requirements of the C of C. Because the packaging is NRC-approved, users need to be familiar with Title 10 Code of Federal Regulations (CFR) 71.8. Any time a user suspects or has indications that the conditions of approval in the C of C were not met, the Carlsbad Field Office (CBFO) shall be notified immediately. The CBFO will evaluate the issue and notify the NRC if required. In accordance with 10 CFR Part 71, certificate holders, packaging users, and contractors or subcontractors who use, design, fabricate, test, maintain, or modify the packaging shall post copies of (1) 10 CFR Part 21 regulations, (2) Section 206 of the Energy Reorganization Act of 1974, and (3) NRC Form 3, Notice to Employees. These documents must be posted in a conspicuous location where the activities subject to these regulations

  7. RH Packaging Program Guidance

    International Nuclear Information System (INIS)

    2008-01-01

    The purpose of this program guidance document is to provide the technical requirements for use, operation, inspection, and maintenance of the RH-TRU 72-B Waste Shipping Package (also known as the 'RH-TRU 72-B cask') and directly related components. This document complies with the requirements as specified in the RH-TRU 72-B Safety Analysis Report for Packaging (SARP), and Nuclear Regulatory Commission (NRC) Certificate of Compliance (C of C) 9212. If there is a conflict between this document and the SARP and/or C of C, the C of C shall govern. The C of C states: 'each package must be prepared for shipment and operated in accordance with the procedures described in Chapter 7.0, Operating Procedures, of the application.' It further states: 'each package must be tested and maintained in accordance with the procedures described in Chapter 8.0, Acceptance Tests and Maintenance Program of the Application.' Chapter 9.0 of the SARP tasks the Waste Isolation Pilot Plant (WIPP) Management and Operating (M and O) Contractor with assuring the packaging is used in accordance with the requirements of the C of C. Because the packaging is NRC-approved, users need to be familiar with Title 10 Code of Federal Regulations (CFR) 71.8, 'Deliberate Misconduct.' Any time a user suspects or has indications that the conditions of approval in the C of C were not met, the U.S. Department of Energy (DOE) Carlsbad Field Office (CBFO) shall be notified immediately. The CBFO will evaluate the issue and notify the NRC if required.In accordance with 10 CFR Part 71, 'Packaging and Transportation of Radioactive Material,' certificate holders, packaging users, and contractors or subcontractors who use, design, fabricate, test, maintain, or modify the packaging shall post copies of (1) 10 CFR Part 21, 'Reporting of Defects and Noncompliance,' regulations, (2) Section 206 of the Energy Reorganization Act of 1974, and (3) NRC Form 3, Notice to Employees. These documents must be posted in a conspicuous

  8. RH Packaging Program Guidance

    International Nuclear Information System (INIS)

    2006-01-01

    The purpose of this program guidance document is to provide the technical requirements for use, operation, inspection, and maintenance of the RH-TRU 72-B Waste Shipping Package and directly related components. This document complies with the requirements as specified in the RH-TRU 72-B Safety Analysis Report for Packaging (SARP), and Nuclear Regulatory Commission (NRC) Certificate of Compliance (C of C) 9212. If there is a conflict between this document and the SARP and/or C of C, the C of C shall govern. The C of C states: 'each package must be prepared for shipment and operated in accordance with the procedures described in Chapter 7.0, Operating Procedures, of the application.' It further states: 'each package must be tested and maintained in accordance with the procedures described in Chapter 8.0, Acceptance Tests and Maintenance Program of the Application.' Chapter 9.0 of the SARP tasks the Waste Isolation Pilot Plant (WIPP) Management and Operating (M and O) Contractor with assuring the packaging is used in accordance with the requirements of the C of C. Because the packaging is NRC-approved, users need to be familiar with 10 Code of Federal Regulations (CFR) 1.8, 'Deliberate Misconduct.' Any time a user suspects or has indications that the conditions of approval in the C of C were not met, the U.S. Department of Energy (DOE) Carlsbad Field Office (CBFO) shall be notified immediately. CBFO will evaluate the issue and notify the NRC if required. In accordance with 10 CFR Part 71, 'Packaging and Transportation of Radioactive Material,' certificate holders, packaging users, and contractors or subcontractors who use, design, fabricate, test, maintain, or modify the packaging shall post copies of (1) 10 CFR Part 21, 'Reporting of Defects and Noncompliance,' regulations, (2) Section 206 of the Energy Reorganization Act of 1974, and (3) NRC Form 3, Notice to Employees. These documents must be posted in a conspicuous location where the activities subject to these

  9. Safety analysis report: packages. LP-12 tritium package (packaging of fissile and other radioactive materials). Final report

    International Nuclear Information System (INIS)

    Gates, A.A.; McCarthy, P.G.; Edl, J.W.

    1975-05-01

    Elemental tritium is shipped at low pressure in a stainless steel container (LP-12) within an aluminum vessel and surrounded by 3.9 in.-thick Celotex insulation in a steel drum. Information is presented on the packaging design, evaluation of the structural, thermal, containment, shielding, and criticality characteristics of the package, procedures for loading, unloading, transporting, and testing the LP-12, and quality assurance requirements. (U.S.)

  10. Insertion in Persian

    Science.gov (United States)

    Kambuziya, Aliyeh Kord-e Zafaranlu; Dehghan, Masoud

    2011-01-01

    This paper investigates epenthesis process in Persian to catch some results in relating to vowel and consonant insertion in Persian lexicon. This survey has a close relationship to the description of epenthetic consonants and the conditions in which these consonants are used. Since no word in Persian may begin with a vowel, so that hiatus can't be…

  11. 40 CFR 157.27 - Unit packaging.

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 23 2010-07-01 2010-07-01 false Unit packaging. 157.27 Section 157.27 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) PESTICIDE PROGRAMS PACKAGING REQUIREMENTS FOR PESTICIDES AND DEVICES Child-Resistant Packaging § 157.27 Unit packaging. Pesticide products...

  12. CH Packaging Program Guidance

    International Nuclear Information System (INIS)

    2005-01-01

    The purpose of this document is to provide the technical requirements for preparation for use, operation, inspection, and maintenance of a Transuranic Package Transporter Model II (TRUPACT-II), a HalfPACT shipping package, and directly related components. This document complies with the minimum requirements as specified in the TRUPACT-II Safety Analysis Report for Packaging (SARP), HalfPACT SARP, and U.S. Nuclear Regulatory Commission (NRC) Certificates of Compliance (C of C) 9218 and 9279, respectively. In the event of a conflict between this document and the SARP or C of C, the C of C shall govern. The C of Cs state: ''each package must be prepared for shipment and operated in accordance with the procedures described in Chapter 7.0, Operating Procedures, of the application.'' They further state: ''each package must be tested and maintained in accordance with the procedures described in Chapter 8.0, Acceptance Tests and Maintenance Program of the Application.'' Chapter 9.0 of the SARP charges the Waste Isolation Pilot Plant (WIPP) management and operating (M and O) contractor with assuring packaging is used in accordance with the requirements of the C of C. Because the packaging is NRC-approved, users need to be familiar with Title 10 Code of Federal Regulations (CFR) 71.8. Any time a user suspects or has indications that the conditions of approval in the C of C were not met, the Carlsbad Field Office (CBFO) shall be notified immediately. The CBFO will evaluate the issue and notify the NRC if required.

  13. 40 CFR 262.30 - Packaging.

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 25 2010-07-01 2010-07-01 false Packaging. 262.30 Section 262.30... APPLICABLE TO GENERATORS OF HAZARDOUS WASTE Pre-Transport Requirements § 262.30 Packaging. Before... the waste in accordance with the applicable Department of Transportation regulations on packaging...

  14. Project monitoring package (PMP) : A package for project activity monitoring

    International Nuclear Information System (INIS)

    Vyas, K.N.; Kannan, A.; Susandhi, R.; Basu, S.

    1987-01-01

    A package for preparing PERT/CPM network diagrams has been written for PDP-11/34. The program uses PLOT-10 library calls for device interfacing. The package is essentially non-interactive in nature, and reads input data in the form of activity description and duration. It calculates the critical path time and performs time scaling of the events. The report gives a brief outline of the logic used, a sample plot and tabular output for reference. An additional facility for performing project activity monitoring has also been implemented. Activity monitoring generally requires various reports such as feed back reports from various group co-ordinators, information report for project co-ordinator and brief periodical reports for management. A package 'DATATRIEVE' (DTR) on PDP-11/34 system is utilized for generating the above mentioned reports. As DTR can also use normal sequential files, an interfacing program has been written which reformats the files accepted by PERT program acceptable to DTR. Various types of reports as generated by DTR are included. However this part of the package is not transportable and can be implemented only on systems having DTR. 6 figures. (author)

  15. Perfume Packaging, Seduction and Gender

    Directory of Open Access Journals (Sweden)

    Magdalena Petersson McIntyre

    2013-06-01

    Full Text Available This article examines gender and cultural sense-making in relation to perfumes and their packaging. Gendered meanings of seduction, choice, consumption and taste are brought to the fore with the use of go-along interviews with consumers in per-fume stores. Meeting luxury packages in this feminized environment made the interviewed women speak of bottles as objects to fall in love with and they de-scribed packages as the active part in an act of seduction where they were expect-ing packages to persuade them into consumption. The interviewed men on the other hand portrayed themselves as active choice-makers and stressed that they were always in control and not seduced by packaging. However, while their ways of explaining their relationship with packaging on the surface seems to confirm cultural generalizations in relation to gender and seduction, the article argues that letting oneself be seduced is no less active than seducing. Based on a combination of actor network theories and theories of gender performativity the article points to the agency of packaging for constructions of gender and understands the inter-viewees as equally animated by the flows of passion which guide their actions.

  16. Naval Waste Package Design Sensitivity

    International Nuclear Information System (INIS)

    T. Schmitt

    2006-01-01

    The purpose of this calculation is to determine the sensitivity of the structural response of the Naval waste packages to varying inner cavity dimensions when subjected to a comer drop and tip-over from elevated surface. This calculation will also determine the sensitivity of the structural response of the Naval waste packages to the upper bound of the naval canister masses. The scope of this document is limited to reporting the calculation results in terms of through-wall stress intensities in the outer corrosion barrier. This calculation is intended for use in support of the preliminary design activities for the license application design of the Naval waste package. It examines the effects of small changes between the naval canister and the inner vessel, and in these dimensions, the Naval Long waste package and Naval Short waste package are similar. Therefore, only the Naval Long waste package is used in this calculation and is based on the proposed potential designs presented by the drawings and sketches in References 2.1.10 to 2.1.17 and 2.1.20. All conclusions are valid for both the Naval Long and Naval Short waste packages

  17. Radioactive material packaging performance testing

    International Nuclear Information System (INIS)

    Romano, T.

    1992-06-01

    In an effort to provide uniform packaging of hazardous material on an international level, recommendations for the transport of dangerous goods have been developed by the United Nations. These recommendations are performance oriented and contrast with a large number of packaging specifications in the US Department of Transportation's hazard materials regulations. This dual system presents problems when international shipments enter the US Department of Transportation's system. Faced with the question of continuing a dual system or aligning with the international system, the Research and Special Programs Administration of the US Department of Transportation responded with Docket HM-181. This began the transition toward the international transportation system. Following close behind is Docket HM-169A, which addressed low specific activity radioactive material packaging. This paper will discuss the differences between performance-oriented and specification packaging, the transition toward performance-oriented packaging by the US Department of Transportation, and performance-oriented testing of radioactive material packaging by Westinghouse Hanford Company. Dockets HM-181 and HM-169A will be discussed along with Type A (low activity) and Type B (high activity) radioactive material packaging evaluations

  18. Cooperative heteroassembly of the adenoviral L4-22K and IVa2 proteins onto the viral packaging sequence DNA.

    Science.gov (United States)

    Yang, Teng-Chieh; Maluf, Nasib Karl

    2012-02-21

    Human adenovirus (Ad) is an icosahedral, double-stranded DNA virus. Viral DNA packaging refers to the process whereby the viral genome becomes encapsulated by the viral particle. In Ad, activation of the DNA packaging reaction requires at least three viral components: the IVa2 and L4-22K proteins and a section of DNA within the viral genome, called the packaging sequence. Previous studies have shown that the IVa2 and L4-22K proteins specifically bind to conserved elements within the packaging sequence and that these interactions are absolutely required for the observation of DNA packaging. However, the equilibrium mechanism for assembly of IVa2 and L4-22K onto the packaging sequence has not been determined. Here we characterize the assembly of the IVa2 and L4-22K proteins onto truncated packaging sequence DNA by analytical sedimentation velocity and equilibrium methods. At limiting concentrations of L4-22K, we observe a species with two IVa2 monomers and one L4-22K monomer bound to the DNA. In this species, the L4-22K monomer is promoting positive cooperative interactions between the two bound IVa2 monomers. As L4-22K levels are increased, we observe a species with one IVa2 monomer and three L4-22K monomers bound to the DNA. To explain this result, we propose a model in which L4-22K self-assembly on the DNA competes with IVa2 for positive heterocooperative interactions, destabilizing binding of the second IVa2 monomer. Thus, we propose that L4-22K levels control the extent of cooperativity observed between adjacently bound IVa2 monomers. We have also determined the hydrodynamic properties of all observed stoichiometric species; we observe that species with three L4-22K monomers bound have more extended conformations than species with a single L4-22K bound. We suggest this might reflect a molecular switch that controls insertion of the viral DNA into the capsid.

  19. RASPLAV package

    International Nuclear Information System (INIS)

    1990-01-01

    The RASPLAV package for investigation of post-accident mass transport and heat transfer processes is presented. The package performs three dimensional thermal conduction calculations in space nonuniform and temperature dependent conductivities and variable heat sources, taking into account phase transformations. The processes of free-moving bulk material, mixing of melting fuel due to advection and dissolution, and also evaporation/adsorption are modelled. Two-dimensional hydrodynamics with self-consistent heat transfer are also performed. The paper briefly traces the ways the solution procedures are carried out in the program package and outlines the major results of the simulation of reactor vessel melting after a core meltdown. The theoretical analysis and the calculations in this case were carried out in order to define the possibility of localization of the zone reminders. The interactions between the reminders and the concrete are simulated and evaluation of the interaction parameters is carried out. 4 refs. (R.Ts)

  20. 7 CFR 58.640 - Packaging.

    Science.gov (United States)

    2010-01-01

    ... 7 Agriculture 3 2010-01-01 2010-01-01 false Packaging. 58.640 Section 58.640 Agriculture Regulations of the Department of Agriculture (Continued) AGRICULTURAL MARKETING SERVICE (Standards... Procedures § 58.640 Packaging. The packaging of the semifrozen product shall be done by means which will in...

  1. Emergency response packaging: A conceptual outline

    International Nuclear Information System (INIS)

    Luna, R.E.; McClure, J.D.; Bennett, P.C.; Wheeler, T.A.

    1992-01-01

    The Packaging and Transportation Needs in the 1990's (PATN) component of the Transportation Assessment and Integration (TRAIN) program (DOE Nov. 1991) was designed to survey United States Department of Energy programs, both ongoing and planned, to identify needs for packaging and transportation services over the next decade. PATN also identified transportation elements that should be developed by the DOE Office of Environmental Restoration and Waste Management (DOE EM) Transportation Management Program (TMP). As a result of the predominant involvement of the TMP in radioactive material shipment issues and DOE EM's involvement with waste management issues, the primary focus of PATN was on waste packaging issues. Pending DOE regulations will formalize federal guidelines and regulations for transportation of hazardous and radioactive materials within the boundaries of DOE reservations and facilities and reflect a growing awareness of concern regarding safety environmental responsibility activities on DOE reservations. Future practices involving the transportation of radioactive material within DOE reservations will closely parallel those used for commercial and governmental transportation across the United States. This has added to the perceived need for emergency recovery packaging and emergency response features on primary packaging, for both on-site shipments and shipments between DOE facilities (off-site). Historically, emergency response and recovery functions of packaging have not been adequately considered in packaging design and construction concepts. This paper develops the rationale for emergency response packaging, including both overpack concepts for repackaging compromised packaging and primary packaging redesign to facilitate the recovery of packages via mobile remote handling equipment. The rationale will examine concepts for determination of likely use patterns to identify types of shipments where recovery packaging may have the most favorable payoff

  2. Sustainable packaging. Packaging for a circular economy; Duurzaam verpakken. Verpakken voor de circulaire economie

    Energy Technology Data Exchange (ETDEWEB)

    Haffmans, S. [Partners for Innovation, Amsterdam (Netherlands); Standhardt, G. [Nederlands Verpaskkingscentrum NVC, Gouda (Netherlands); Hamer, A. [Agentschap NL, Utrecht (Netherlands)

    2013-10-15

    What is Sustainable Packaging? And what is the most sustainable packaging for a product? The publication is intended for anyone who wants to take into account the environment in the design of a product and packaging. It offers concrete suggestions and inspiring examples to bring sustainable packaging into practice [Dutch] Wat is Duurzaam Verpakken? En wat is de duurzaamste verpakking voor mijn product? De publicatie is bestemd voor iedereen die rekening wil houden met het milieu bij het ontwerp van een product-verpakkingscombinatie. Ze biedt concrete aanknopingspunten en inspirerende voorbeelden om hier praktisch mee aan de slag te gaan.

  3. AN ADA NAMELIST PACKAGE

    Science.gov (United States)

    Klumpp, A. R.

    1994-01-01

    The Ada Namelist Package, developed for the Ada programming language, enables a calling program to read and write FORTRAN-style namelist files. A namelist file consists of any number of assignment statements in any order. Features of the Ada Namelist Package are: the handling of any combination of user-defined types; the ability to read vectors, matrices, and slices of vectors and matrices; the handling of mismatches between variables in the namelist file and those in the programmed list of namelist variables; and the ability to avoid searching the entire input file for each variable. The principle user benefits of this software are the following: the ability to write namelist-readable files, the ability to detect most file errors in the initialization phase, a package organization that reduces the number of instantiated units to a few packages rather than to many subprograms, a reduced number of restrictions, and an increased execution speed. The Ada Namelist reads data from an input file into variables declared within a user program. It then writes data from the user program to an output file, printer, or display. The input file contains a sequence of assignment statements in arbitrary order. The output is in namelist-readable form. There is a one-to-one correspondence between namelist I/O statements executed in the user program and variables read or written. Nevertheless, in the input file, mismatches are allowed between assignment statements in the file and the namelist read procedure statements in the user program. The Ada Namelist Package itself is non-generic. However, it has a group of nested generic packages following the nongeneric opening portion. The opening portion declares a variety of useraccessible constants, variables and subprograms. The subprograms are procedures for initializing namelists for reading, reading and writing strings. The subprograms are also functions for analyzing the content of the current dataset and diagnosing errors. Two nested

  4. Insert Design and Manufacturing for Foam-Core Composite Sandwich Structures

    Science.gov (United States)

    Lares, Alan

    Sandwich structures have been used in the aerospace industry for many years. The high strength to weight ratios that are possible with sandwich constructions makes them desirable for airframe applications. While sandwich structures are effective at handling distributed loads such as aerodynamic forces, they are prone to damage from concentrated loads at joints or due to impact. This is due to the relatively thin face-sheets and soft core materials typically found in sandwich structures. Carleton University's Uninhabited Aerial Vehicle (UAV) Project Team has designed and manufactured a UAV (GeoSury II Prototype) which features an all composite sandwich structure fuselage structure. The purpose of the aircraft is to conduct geomagnetic surveys. The GeoSury II Prototype serves as the test bed for many areas of research in advancing UAV technologies. Those areas of research include: low cost composite materials manufacturing, geomagnetic data acquisition, obstacle detection, autonomous operations and magnetic signature control. In this thesis work a methodology for designing and manufacturing inserts for foam-core sandwich structures was developed. The results of this research work enables a designer wishing to design a foam-core sandwich airframe structure, a means of quickly manufacturing optimized inserts for the safe introduction of discrete loads into the airframe. The previous GeoSury II Prototype insert designs (v.1 & v.2) were performance tested to establish a benchmark with which to compare future insert designs. Several designs and materials were considered for the new v.3 inserts. A plug and sleeve design was selected, due to its ability to effectively transfer the required loads to the sandwich structure. The insert material was chosen to be epoxy, reinforced with chopped carbon fibre. This material was chosen for its combination of strength, low mass and also compatibility with the face-sheet material. The v.3 insert assembly is 60% lighter than the

  5. 21 CFR 820.130 - Device packaging.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Device packaging. 820.130 Section 820.130 Food and... QUALITY SYSTEM REGULATION Labeling and Packaging Control § 820.130 Device packaging. Each manufacturer shall ensure that device packaging and shipping containers are designed and constructed to protect the...

  6. 76 FR 30551 - Specifications for Packagings

    Science.gov (United States)

    2011-05-26

    ... design qualification test and each periodic retest on a packaging, a test report must be prepared. The... where the design qualification tests are conducted, for as long as the packaging is produced and for at... report; (5) Manufacturer of the packaging; (6) Description of the packaging design type (e.g. dimensions...

  7. Patterns of transposable element expression and insertion in cancer

    Directory of Open Access Journals (Sweden)

    Evan A Clayton

    2016-11-01

    Full Text Available Human transposable element (TE activity in somatic tissues causes mutations that can contribute to tumorigenesis. Indeed, TE insertion mutations have been implicated in the etiology of a number of different cancer types. Nevertheless, the full extent of somatic TE activity, along with its relationship to tumorigenesis, have yet to be fully explored. Recent developments in bioinformatics software make it possible to analyze TE expression levels and TE insertional activity directly from transcriptome (RNA-seq and whole genome (DNA-seq next-generation sequence data. We applied these new sequence analysis techniques to matched normal and primary tumor patient samples from the Cancer Genome Atlas (TCGA in order to analyze the patterns of TE expression and insertion for three cancer types: breast invasive carcinoma, head and neck squamous cell carcinoma, and lung adenocarcinoma. Our analysis focused on the three most abundant families of active human TEs: Alu, SVA and L1. We found evidence for high levels of somatic TE activity for these three families in normal and cancer samples across diverse tissue types. Abundant transcripts for all three TE families were detected in both normal and cancer tissues along with an average of ~80 unique TE insertions per individual patient/tissue. We observed an increase in L1 transcript expression and L1 insertional activity in primary tumor samples for all three cancer types. Tumor-specific TE insertions are enriched for private mutations, consistent with a potentially causal role in tumorigenesis. We used genome feature analysis to investigate two specific cases of putative cancer-causing TE mutations in further detail. An Alu insertion in an upstream enhancer of the CBL tumor suppressor gene is associated with down-regulation of the gene in a single breast cancer patient, and an L1 insertion in the first exon of the BAALC gene also disrupts its expression in head and neck squamous cell carcinoma. Our results are

  8. Package Formats for Preserved Digital Material

    DEFF Research Database (Denmark)

    Zierau, Eld

    2012-01-01

    This paper presents an investigation of the best suitable package formats for long term digital preservation. The choice of a package format for preservation is crucial for future access, thus a thorough analysis of choice is important. The investigation presented here covers setting up requireme......This paper presents an investigation of the best suitable package formats for long term digital preservation. The choice of a package format for preservation is crucial for future access, thus a thorough analysis of choice is important. The investigation presented here covers setting up...... requirements for package formats used for long term preserved digital material, and using these requirements as the basis for analysing a range of package formats. The result of the concrete investigation is that the WARC format is the package format best suited for the listed requirements. Fulfilling...

  9. Directory of Certificates of Compliance for Radioactive-Materials Packages. Summary report of NRC approved packages

    International Nuclear Information System (INIS)

    1983-01-01

    This directory contains a Summary Report of the US Nuclear Regulatory Commission's Approved Packages (Volume I), all Certificates of Compliance (Volume 2), and Summary Report of NRC Approved Quality Assurance Programs (Volume 3) for Radioactive Material Packages effective December 31, 1982. The purpose of this directory is to make available a convenient source of information on packagings which have been approved by the US Nuclear Regulatory Commission. To assist in identifying packaging, an index by Model Number and corresponding Certificate of Compliance Number is included at the back of Volumes 1 and 2 of the directory. A listing by packaging types is included in the back of Volume 2. An alphabetical listing by company name is included in the back of Volume 3 for approved QA programs. The Summary Reports include a listing of all users of each package design and approved QA programs prior to the publication date of the directory

  10. 9 CFR 354.72 - Packaging.

    Science.gov (United States)

    2010-01-01

    ... 9 Animals and Animal Products 2 2010-01-01 2010-01-01 false Packaging. 354.72 Section 354.72... CERTIFICATION VOLUNTARY INSPECTION OF RABBITS AND EDIBLE PRODUCTS THEREOF Supervision of Marking and Packaging § 354.72 Packaging. No container which bears or may bear any official identification or any abbreviation...

  11. Antimicrobial packaging with natural compunds - a review

    Directory of Open Access Journals (Sweden)

    Renata Dobrucka

    2016-12-01

    Full Text Available Background:  Packaging problems are an integral part of logistics and the implementation of packaging significantly affects the effectiveness of logistics processes, as a factor which increases the safety and the quality of products being transported. Active packaging is an area of technology needed to meet the requirements of the contemporary consumer. Active packaging creates additional opportunities in systems for packing goods, as well as offering a solution in which the packaging, the product and surroundings interact. Furthermore, active packaging allows packaging to interact with food and the environment and play a dynamic role in food preservation. The main role of antimicrobial packaging is to inhibit the growth of microorganisms that reduce the quality of the packaged product. Methods: The application of natural antimicrobial agents appears to be safe for food products. Also, these compounds have potential applications as a natural preservative in the food packaging industry. This study presents some antibacterial agents, namely chitosan, nisin and pectins. Results and conclusion: Natural substances used in active packaging can eliminate the danger of chemical substances migrating to food.

  12. Overview of the DOE packaging certification process

    Energy Technology Data Exchange (ETDEWEB)

    Liu, Y.Y.; Carlson, R.D. [Argonne National Lab., IL (United States); Carlson, R.W. [Lawrence Livermore National Lab., CA (United States); Kapoor, A. [USDOE, Washington, DC (United States)

    1995-12-31

    This paper gives an overview of the DOE packaging certification process, which is implemented by the Office of Facility Safety Analysis, under the Assistance Secretary for Environment, Safety and Health, for packagings that are not used for weapons and weapons components, nor for naval nuclear propulsion. The overview will emphasize Type B packagings and the Safety Analysis Report for Packaging (SARP) review that parallels the NRC packaging review. Other important elements in the DOE packaging certification program, such as training, methods development, data bases, and technical assistance, are also emphasized, because they have contributed significantly to the improvement of the certification process since DOE consolidated its packaging certification function in 1985. The paper finishes with a discussion of the roles and functions of the DOE Packaging Safety Review Steering Committee, which is chartered to address issues and concerns of interest to the DOE packaging and transportation safety community. Two articles related to DOE packaging certification were published earlier on the SARP review procedures and the DOE Packaging Review Guide. These articles may be consulted for additional information.

  13. E2LEMI:Energy-Efficient Logic Encryption Using Multiplexer Insertion

    Directory of Open Access Journals (Sweden)

    Qutaiba Alasad

    2017-02-01

    Full Text Available Due to the outsourcing of chip manufacturing, countermeasures against Integrated Circuit (IC piracy, reverse engineering, IC overbuilding and hardware Trojans (HTs become a hot research topic. To protect an IC from these attacks, logic encryption techniques have been considered as a low-cost defense mechanism. In this paper, our proposal is to insert the multiplexer (MUX with two cases: (i we randomly insert MUXs equal to half of the output bit number (half MUX insertions; and (ii we insert MUXs equal to the number of output bits (full MUX insertions. Hamming distance is adopted as a security evaluation. We also measure the delay, power and area overheads with the proposed technique.

  14. Radiological Tenckhoff catheter insertion for peritoneal dialysis: A cost-effective approach.

    Science.gov (United States)

    Lee, James; Mott, Nigel; Mahmood, Usman; Clouston, John; Summers, Kara; Nicholas, Pauline; Gois, Pedro Henrique França; Ranganathan, Dwarakanathan

    2018-04-01

    Radiological insertion of Tenckhoff catheters can be an alternative option for peritoneal dialysis access creation, as compared to surgical catheter insertion. This study will review the outcomes and complications of radiological Tenckhoff catheter insertion in a metropolitan renal service and compare costs between surgical and radiological insertion. Data were collected prospectively for all patients who had a Tenckhoff catheter insertion for peritoneal dialysis (PD) under radiological guidance at our hospital from May 2014 to November 2016. The type of catheter used and complications, including peri-catheter leak, exit site infection and peritonitis were reviewed. Follow-up data were also collected at points 3, 6 and 12 months from catheter insertion. Costing data were obtained from Queensland Health Electronic Reporting System (QHERS) data, average staff salaries and consumable contract price lists. In the 30-month evaluation period, 70 catheters were inserted. Two patients had an unsuccessful procedure due to the presence of abdominal adhesions. Seven patients had an episode of peri-catheter leak, and four patients had an exit site infection following catheter insertion. Peritonitis was observed in nine patients during the study period. The majority of patients (90%) remained on peritoneal dialysis at 3-month follow-up. The average costs of surgical and radiological insertion were noted to be AUD$7788.34 and AUD$1597.35, respectively. Radiological Tenckhoff catheter insertion for peritoneal dialysis appears to be an attractive and cost-effective option given less waiting periods for the procedure, the relatively low cost of insertion and comparable rates of complications. © 2017 The Royal Australian and New Zealand College of Radiologists.

  15. Prevention of lymphocele by using gelatin-thrombin matrix as a tissue sealant after pelvic lymphadenectomy in patients with gynecologic cancers: a prospective randomized controlled study.

    Science.gov (United States)

    Kim, Yun Hwan; Shin, Hyun Joo; Ju, Woong; Kim, Seung Cheol

    2017-05-01

    This prospective randomized controlled pilot study aimed to find whether gelatin-thrombin matrix used as a tissue sealant (FloSeal) can prevent the occurrence of pelvic lymphocele in patients with gynecologic cancer who has undergone pelvic lymphadenectomy. Each patient, who undergo a laparotomic pelvic lymph node dissection on both sides, was randomly assigned for FloSeal application on 1 side of the pelvis. The other side of the pelvis without any product application being the control side. The amount of lymph drainage at each side of the pelvis was measured for 3 days, and computed tomography scans were obtained 7 days and 6 months after surgery for detection of pelvic lymphocele. Among 37 cases, the median amount of lymph drainage was significantly decreased in the hemi-pelvis treated with FloSeal compared to the control hemi-pelvis (p=0.025). The occurrence of lymphocele was considerably reduced in treated hemi-pelvis (8/37, 21.6%) compared with control hemi-pelvis (12/37, 32.4%) after 7 post-operative days (p=0.219), and more decreased in the treated hemi-pelvis (5/37, 13.5%) compared with control hemi-pelvis (9/37, 24.3%) after postoperative 6 months (p=0.344). The application of FloSeal as a tissue sealant in lymph nodes resected tissues can reduce the incidence of pelvic lymphocele in gynecologic cancer patients. A large randomized controlled study could confirm these preliminary results. Copyright © 2017. Asian Society of Gynecologic Oncology, Korean Society of Gynecologic Oncology

  16. Performance of a polymer sealant coating in an arctic marine environment

    International Nuclear Information System (INIS)

    Moskowitz, P.; Cowgill, M.; Griffith, A.; Chernaenko, L.; Diashev, A.; Nazarian, A.

    2001-01-01

    The feasibility of using a polymer-based coating, Polibrid 705, to seal concrete and steel surfaces from permanent radioactive contamination in an Arctic marine environment has been successfully demonstrated using a combination of field and laboratory testing. A mobile, self-sufficient spraying device was developed to specifications provided by the Russian Northern Navy and deployed at the RTP Atomflot site, Murmansk, Russia. Demonstration coatings were applied to concrete surfaces exposed to conditions ranging from indoor pedestrian usage to heavy vehicle passage and container handling in a loading dock. A large steel container was also coated with the polymer, filled with solid radwaste, sealed, and left out of doors, exposed to the full annual Arctic weather cycle. The 12 months of field testing gave rise to little degradation of the sealant coating, except for a few chips and gouge marks on the loading bay surface that were readily repaired. Contamination resulting from radwaste handling was easily removed and the surface was not degraded by contact with the decontamination agents. The field tests were accompanied by a series of laboratory qualification tests carried out at a research laboratory in St. Petersburg. The laboratory tests examined a variety of properties, including bond strength between the coating and the substrate, thermal cycling resistance, wear resistance, flammability, and ease of decontamination. The Polibrid 705 coating met all the Russian Navy qualification requirements with the exception of flammability. In this last instance, it was decided to restrict application of the coating to land-based facilities

  17. Silver microparticles plus fibrin tissue sealant prevents incisional hernias in rats.

    Science.gov (United States)

    Primus, Frank E; Young, David M; Grenert, James P; Harris, Hobart W

    2018-07-01

    Open abdominal surgery is frequently complicated by the subsequent development of an incisional hernia. Consequently, more than 400,000 incisional hernia repairs are performed each year, adding over $15 billion per year to U.S. health-care expenditures. While the vast majority of studies have focused on improved surgical techniques or prosthetic materials, we examined the use of metallic silver microparticles to prevent incisional hernia formation through enhanced wound healing. A rodent incisional hernia model was used. Eighty-two rats were randomly placed into two control groups (saline alone and silver microparticles alone), and three experimental groups (0 mg/cm, 2.5 mg/cm, and 25 mg/cm of silver microparticles applied with a fibrin sealant). Incisional hernia incidence and size, tensile strength, and tissue histology were assessed after 28 days. A significant reduction of both incisional hernia incidence and hernia size was observed between the control groups and 2.5 mg/cm group, and between the control and 25 mg/cm group by nearly 60% and 90%, respectively (P < 0.05). Histological samples showed a noticeable increase in new fibrosis in the treated animals as compared with the controls, whereas the tensile strength between the groups did not differ. The novel approach of using silver microparticles to enhance wound healing appears to be a safe and effective method to prevent incisional hernias from developing and could herald a new era of medicinal silver use. Copyright © 2018 Elsevier Inc. All rights reserved.

  18. Safety analysis report: packages. LP-50 tritium package (packaging of fissile and other radioactive materials). Final report

    International Nuclear Information System (INIS)

    Gates, A.A.; McCarthy, P.G.; Edl, J.W.

    1975-04-01

    Elemental tritium is shipped at low pressure in a stainless steel container (LP-50) sealed within an aluminum vessel and surrounded by a minimum of 4-in. thick Celotex insulation in a steel drum. The structural, thermal, containment, shielding, and criticality safety aspects of this package are evaluated. Procedures for loading and unloading, empty cask transport, acceptance testing and maintenance, and quality assurance requirements for the LP-50 package are described in detail. (U.S.)

  19. Safety analysis report; packages LP-50 tritium package. (Packaging of fissile and other radioactive materials). Final report

    International Nuclear Information System (INIS)

    Gates, A.A.; McCarthy, P.G.; Edl, J.W.; Chalfant, G.G.

    1975-05-01

    Elemental tritium is shipped at low pressure in a stainless steel container (LP-50) surrounded by an aluminum vessel and Celotex insulation at least 4 in. thick in a steel drum. The total weight of the package is 260 lbs maximum. The various components that constitute the package are described and are shown in 7 figures. The safety analysis includes: structural evaluations; thermal evaluations; containment; operating procedures; acceptance tests and maintenance program; and design review

  20. The Composite Insertion Electrode

    DEFF Research Database (Denmark)

    Atlung, Sven; Zachau-Christiansen, Birgit; West, Keld

    1984-01-01

    The specific energy obtainable by discharge of porous insertion electrodes is limited by electrolyte depletion in thepores. This can be overcome using a solid ion conductor as electrolyte. The term "composite" is used to distinguishthese electrodes from porous electrodes with liquid electrolyte...

  1. A small and efficient dimerization/packaging signal of rat VL30 RNA and its use in murine leukemia virus-VL30-derived vectors for gene transfer.

    Science.gov (United States)

    Torrent, C; Gabus, C; Darlix, J L

    1994-02-01

    Retroviral genomes consist of two identical RNA molecules associated at their 5' ends by the dimer linkage structure located in the packaging element (Psi or E) necessary for RNA dimerization in vitro and packaging in vivo. In murine leukemia virus (MLV)-derived vectors designed for gene transfer, the Psi + sequence of 600 nucleotides directs the packaging of recombinant RNAs into MLV virions produced by helper cells. By using in vitro RNA dimerization as a screening system, a sequence of rat VL30 RNA located next to the 5' end of the Harvey mouse sarcoma virus genome and as small as 67 nucleotides was found to form stable dimeric RNA. In addition, a purine-rich sequence located at the 5' end of this VL30 RNA seems to be critical for RNA dimerization. When this VL30 element was extended by 107 nucleotides at its 3' end and inserted into an MLV-derived vector lacking MLV Psi +, it directed the efficient encapsidation of recombinant RNAs into MLV virions. Because this VL30 packaging signal is smaller and more efficient in packaging recombinant RNAs than the MLV Psi + and does not contain gag or glyco-gag coding sequences, its use in MLV-derived vectors should render even more unlikely recombinations which could generate replication-competent viruses. Therefore, utilization of the rat VL30 packaging sequence should improve the biological safety of MLV vectors for human gene transfer.

  2. Additive Manufacturing for Highly Efficient Window Inserts CRADA Report

    Energy Technology Data Exchange (ETDEWEB)

    Roschli, Alex C. [ORNL; Chesser, Phillip C. [ORNL; Love, Lonnie J. [ORNL

    2018-04-01

    ORNL partnered with the Mackinac Technology Company to demonstrate how additive manufacturing can be used to create highly energy efficient window inserts for retrofit in pre-existing buildings. Many early iterations of the window inserts were fabricated using carbon fiber reinforced thermoplastics and polycarbonate films as a stand in for the low-e coated films produced by the Mackinac Technology Company. After demonstration of the proof of concept, i.e. custom window inserts with tensioned film, the materials used for the manufacture of the frames was more closely examined. Hollow particle-filled syntactic foam and low-density polymer composites formed by expandable microspheres were explored as the materials used to additively manufacture the frames of the inserts. It was concluded that low-cost retrofit window inserts in custom sizes could be easily fabricated using large scale additive manufacturing. Furthermore, the syntactic and expanded foams developed and tested satisfy the mechanical performance requirements for the application.

  3. Large transport packages for decommissioning waste

    International Nuclear Information System (INIS)

    Price, M.S.T.

    1988-08-01

    This document reports progress on a study of large transport packages for decommissioning waste and is the semi-annual report for the period 1 January - 30 June 1988. The main tasks performed during the period related to the assembly of package design criteria ie those aspects of manufacture, handling, storage, transport and disposal which impose constraints on design. This work was synthesised into a design specification for packages which formed the conclusion of that task and was the entry into the final task - the development of package design concepts. The design specifications, which concentrated on the Industrial Package category of the IAEA Transport Regulations, has been interpreted for the two main concepts (a) a self-shielded package disposed of in its entirety and (b) a package with returnable shielding. Preliminary information has been prepared on the cost of providing the package as well as transport to a repository and disposal. There is considerable uncertainty about the cost of disposal and variations of over a factor of 10 are possible. Under these circumstances there is merit in choosing a design concept which is relatively insensitive to disposal cost variations. The initial results indicate that on these grounds the package with returnable shielding is preferred. (author)

  4. Innovative Approaches to Large Component Packaging

    International Nuclear Information System (INIS)

    Freitag, A.; Hooper, M.; Posivak, E.; Sullivan, J.

    2006-01-01

    Radioactive waste disposal often times requires creative approaches in packaging design, especially for large components. Innovative design techniques are required to meet the needs for handling, transporting, and disposing of these large packages. Large components (i.e., Reactor Pressure Vessel (RPV) heads and even RPVs themselves) require special packaging for shielding and contamination control, as well as for transport and disposal. WMG Inc designed and used standard packaging for RPV heads without control rod drive mechanisms (CRDMs) attached for five RPV heads and has also more recently met an even bigger challenge and developed the innovative Intact Vessel Head Transport System (IVHTS) for RPV heads with CRDMs intact. This packaging system has been given a manufacturer's exemption by the United States Department of Transportation (USDOT) for packaging RPV heads. The IVHTS packaging has now been successfully used at two commercial nuclear power plants. Another example of innovative packaging is the large component packaging that WMG designed, fabricated, and utilized at the West Valley Demonstration Project (WVDP). In 2002, West Valley's high-level waste vitrification process was shut down in preparation for D and D of the West Valley Vitrification Facility. Three of the major components of concern within the Vitrification Facility were the Melter, the Concentrate Feed Makeup Tank (CFMT), and the Melter Feed Holdup Tank (MFHT). The removal, packaging, and disposition of these three components presented significant radiological and handling challenges for the project. WMG designed, fabricated, and installed special packaging for the transport and disposal of each of these three components, which eliminated an otherwise time intensive and costly segmentation process that WVDP was considering. Finally, WMG has also designed and fabricated special packaging for both the Connecticut Yankee (CY) and San Onofre Nuclear Generating Station (SONGS) RPVs. This paper

  5. RF and microwave microelectronics packaging II

    CERN Document Server

    Sturdivant, Rick

    2017-01-01

    Reviews RF, microwave, and microelectronics assembly process, quality control, and failure analysis Bridges the gap between low cost commercial and hi-res RF/Microwave packaging technologies Engages in an in-depth discussion of challenges in packaging and assembly of advanced high-power amplifiers This book presents the latest developments in packaging for high-frequency electronics. It is a companion volume to “RF and Microwave Microelectronics Packaging” (2010) and covers the latest developments in thermal management, electrical/RF/thermal-mechanical designs and simulations, packaging and processing methods, and other RF and microwave packaging topics. Chapters provide detailed coverage of phased arrays, T/R modules, 3D transitions, high thermal conductivity materials, carbon nanotubes and graphene advanced materials, and chip size packaging for RF MEMS. It appeals to practicing engineers in the electronic packaging and high-frequency electronics domain, and to academic researchers interested in underst...

  6. 49 CFR 173.3 - Packaging and exceptions.

    Science.gov (United States)

    2010-10-01

    ... 49 Transportation 2 2010-10-01 2010-10-01 false Packaging and exceptions. 173.3 Section 173.3... SHIPMENTS AND PACKAGINGS General § 173.3 Packaging and exceptions. (a) The packaging of hazardous materials.... standard packaging must be open to inspection by a representative of the Department. (b) The regulations...

  7. Evaluation of a high resolution silicon PET insert module

    Energy Technology Data Exchange (ETDEWEB)

    Grkovski, Milan, E-mail: milan.grkovski@ijs.si [Jožef Stefan Institute, Ljubljana (Slovenia); Memorial Sloan Kettering Cancer Center, New York, NY (United States); Brzezinski, Karol [IFIC/CSIC, Valencia (Spain); Cindro, Vladimir [Jožef Stefan Institute, Ljubljana (Slovenia); Clinthorne, Neal H. [University of Michigan, Ann Arbor, MI (United States); Kagan, Harris [Ohio State University, Columbus, OH (United States); Lacasta, Carlos [IFIC/CSIC, Valencia (Spain); Mikuž, Marko [Jožef Stefan Institute, Ljubljana (Slovenia); Solaz, Carles [IFIC/CSIC, Valencia (Spain); Studen, Andrej [Jožef Stefan Institute, Ljubljana (Slovenia); Weilhammer, Peter [Ohio State University, Columbus, OH (United States); Žontar, Dejan [Jožef Stefan Institute, Ljubljana (Slovenia)

    2015-07-11

    Conventional PET systems can be augmented with additional detectors placed in close proximity of the region of interest. We developed a high resolution PET insert module to evaluate the added benefit of such a combination. The insert module consists of two back-to-back 1 mm thick silicon sensors, each segmented into 1040 1 mm{sup 2} pads arranged in a 40 by 26 array. A set of 16 VATAGP7.1 ASICs and a custom assembled data acquisition board were used to read out the signal from the insert module. Data were acquired in slice (2D) geometry with a Jaszczak phantom (rod diameters of 1.2–4.8 mm) filled with {sup 18}F-FDG and the images were reconstructed with ML-EM method. Both data with full and limited angular coverage from the insert module were considered and three types of coincidence events were combined. The ratio of high-resolution data that substantially improves quality of the reconstructed image for the region near the surface of the insert module was estimated to be about 4%. Results from our previous studies suggest that such ratio could be achieved at a moderate technological expense by using an equivalent of two insert modules (an effective sensor thickness of 4 mm)

  8. Safety and Effectiveness of Percutaneously Inserted Peritoneal Ports Compared to Surgically Inserted Ports in a Retrospective Study of 87 Patients with Ovarian Carcinoma over a 10-Year Period

    International Nuclear Information System (INIS)

    Woodley-Cook, Joel; Tarulli, Emidio; Tan, Kong T.; Rajan, Dheeraj K.; Simons, Martin E.

    2016-01-01

    PurposePlacement of peritoneal ports has become a favorable technique for direct chemotherapy infusion in treating peritoneal metastases from ovarian cancer. We aim to outline an approach to the percutaneous insertion of peritoneal ports and to characterize success and complication rates compared to surgically inserted ports.Materials and MethodsRetrospective analysis was collected from 87 patients who had peritoneal port insertion (28 inserted surgically and 59 percutaneously) for treatment of peritoneal metastases from ovarian cancer from July 2004 to July 2014. Complications were classified according to the SIR Clinical Practice Guidelines as major or minor.ResultsTechnical success rates for surgically and percutaneously inserted ports were 100 and 96.7 %, respectively (p = 0.44), with the two percutaneous failures successful at a later date. There were no major complications in either group. Minor complication rates for surgically versus percutaneously inserted ports were 46.4 versus 22.0 %, respectively (p = 0.02). The infection rate for surgically inserted versus percutaneously inserted ports was 14.3 and 0 %, respectively (p = 0.002). The relative risk of developing a complication from percutaneous peritoneal port insertion without ascites was 3.4 (p = 0.04). For percutaneously inserted ports, the mean in-room procedure time was 81 ± 1.3 min and mean fluoroscopy time was 5.0 ± 4.5 min.ConclusionPercutaneously inserted peritoneal ports are a safe alternative to surgically inserted ports, demonstrating similar technical success and lower complication rates.

  9. Safety and Effectiveness of Percutaneously Inserted Peritoneal Ports Compared to Surgically Inserted Ports in a Retrospective Study of 87 Patients with Ovarian Carcinoma over a 10-Year Period

    Energy Technology Data Exchange (ETDEWEB)

    Woodley-Cook, Joel, E-mail: jwoodleycook@gmail.com [The Scarborough Hospital, Vascular and Interventional Radiology, Department of Diagnostic Imaging (Canada); Tarulli, Emidio; Tan, Kong T.; Rajan, Dheeraj K.; Simons, Martin E. [University of Toronto, Vascular and Interventional Radiology, Department of Medical Imaging, University Health Network (Canada)

    2016-11-15

    PurposePlacement of peritoneal ports has become a favorable technique for direct chemotherapy infusion in treating peritoneal metastases from ovarian cancer. We aim to outline an approach to the percutaneous insertion of peritoneal ports and to characterize success and complication rates compared to surgically inserted ports.Materials and MethodsRetrospective analysis was collected from 87 patients who had peritoneal port insertion (28 inserted surgically and 59 percutaneously) for treatment of peritoneal metastases from ovarian cancer from July 2004 to July 2014. Complications were classified according to the SIR Clinical Practice Guidelines as major or minor.ResultsTechnical success rates for surgically and percutaneously inserted ports were 100 and 96.7 %, respectively (p = 0.44), with the two percutaneous failures successful at a later date. There were no major complications in either group. Minor complication rates for surgically versus percutaneously inserted ports were 46.4 versus 22.0 %, respectively (p = 0.02). The infection rate for surgically inserted versus percutaneously inserted ports was 14.3 and 0 %, respectively (p = 0.002). The relative risk of developing a complication from percutaneous peritoneal port insertion without ascites was 3.4 (p = 0.04). For percutaneously inserted ports, the mean in-room procedure time was 81 ± 1.3 min and mean fluoroscopy time was 5.0 ± 4.5 min.ConclusionPercutaneously inserted peritoneal ports are a safe alternative to surgically inserted ports, demonstrating similar technical success and lower complication rates.

  10. Materials for advanced packaging

    CERN Document Server

    Wong, CP

    2017-01-01

    This second edition continues to be the most comprehensive review on the developments in advanced electronic packaging technologies, with a focus on materials and processing. Recognized experts in the field contribute to 22 updated and new chapters that provide comprehensive coverage on various 3D package architectures, novel bonding and joining techniques, wire bonding, wafer thinning techniques, organic substrates, and novel approaches to make electrical interconnects between integrated circuit and substrates. Various chapters also address advances in several key packaging materials, including: Lead-free solders Flip chip underfills Epoxy molding compounds Conductive adhesives Die attach adhesives/films Thermal interface materials (TIMS) Materials for fabricating embedded passives including capacitors, inductors, and resistors Materials and processing aspects on wafer-level chip scale package (CSP) and MicroElectroMechanical system (MEMS) Contributors also review new and emerging technologies such as Light ...

  11. Biobased Packaging - Application in Meat Industry

    Directory of Open Access Journals (Sweden)

    S. Wilfred Ruban

    2009-04-01

    Full Text Available Because of growing problems of waste disposal and because petroleum is a nonrenewable resource with diminishing quantities, renewed interest in packaging research is underway to develop and promote the use of “bio-plastics.” In general, compared to conventional plastics derived from petroleum, bio-based polymers have more diverse stereochemistry and architecture of side chains which enable research scientists a greater number of opportunities to customize the properties of the final packaging material. The primary challenge facing the food (Meat industry in producing bio-plastic packaging, currently, is to match the durability of the packaging with product shelf-life. Notable advances in biopolymer production, consumer demand for more environmentally-friendly packaging, and technologies that allow packaging to do more than just encompass the food are driving new and novel research and developments in the area of packaging for muscle foods. [Vet. World 2009; 2(2.000: 79-82

  12. Hermeticity of electronic packages

    CERN Document Server

    Greenhouse, Hal; Romenesco, Bruce

    2011-01-01

    This is a book about the integrity of sealed packages to resist foreign gases and liquids penetrating the seal or an opening (crack) in the packageùespecially critical to the reliability and longevity of electronics. The author explains how to predict the reliability and the longevity of the packages based on leak rate measurements and the assumptions of impurities. Non-specialists in particular will benefit from the author's long involvement in the technology. Hermeticity is a subject that demands practical experience, and solving one problem does not necessarily give one the background to so

  13. Hermeticity of electronic packages

    CERN Document Server

    Greenhouse, Hal

    2000-01-01

    This is a book about the integrity of sealed packages to resist foreign gases and liquids penetrating the seal or an opening (crack) in the package-especially critical to the reliability and longevity of electronics. The author explains how to predict the reliability and the longevity of the packages based on leak rate measurements and the assumptions of impurities. Non-specialists in particular will benefit from the author's long involvement in the technology. Hermeticity is a subject that demands practical experience, and solving one problem does not necessarily give one the background to so

  14. Directory of certificates of compliance for radioactive materials packages; Summary Report of NRC Approved Packages

    International Nuclear Information System (INIS)

    1980-12-01

    This directory contains a Summary Report of NRC approved Packages (Volume 1), Certificates of Compliance (Volume 2), and a Summary Report of NRC Approved Quality Assurance Programs for Radioactive Material Packages (Volume 3). The purpose of this directory is to make available a convenient source of information on packagings which have been approved by the U.S. Nuclear Regulatory Commission. To assist in identifying packaging, and index by Model Number and corresponding Certificate of Compliance number is included at the back of each volume of the directory. The Summary Report includes a listing of all users of each package design prior to the publication date of the directory. Shipments of radioactive material using these packagings must be in accordance with the provisions of 49 CFR 173.393a and 10 CFR Part 71, as applicable. In satisfying the requirements of Section 71.12, it is the responsibility of the licensees to insure them--that they have a copy of the current approval and conduct their transportation activities in accordance with an NRC approved quality assurance program

  15. Energy and packaging

    Energy Technology Data Exchange (ETDEWEB)

    Boustead, I; Hancock, G F

    1981-01-01

    Information is given on the energy and raw materials required in the production and use of containers used to package beer, cider, and carbonated soft drinks in the United Kingdom. Topics covered include: methodology of energy analysis, primary and secondary fuels, transport, packaging materials, including glass, aluminum, iron, steel, and tinplate, container production, including plastic bottles, distribution of empty containers, filling and packing, distribution, and disposal. (LEW)

  16. Enhancement of heat transfer using varying width twisted tape inserts

    African Journals Online (AJOL)

    user

    enhancement of heat transfer with twisted tape inserts as compared to plain ... studies for heat transfer and pressure drop of laminar flow in horizontal tubes ... flow in rectangular and square plain ducts and ducts with twisted-tape inserts .... presence of the insert in the pipe causes resistance to flow and increases turbulence.

  17. Signalling product healthiness through symbolic package cues: Effects of package shape and goal congruence on consumer behaviour.

    Science.gov (United States)

    van Ooijen, Iris; Fransen, Marieke L; Verlegh, Peeter W J; Smit, Edith G

    2017-02-01

    Three studies show that product packaging shape serves as a cue that communicates healthiness of food products. Inspired by embodiment accounts, we show that packaging that simulates a slim body shape acts as a symbolic cue for product healthiness (e.g., low in calories), as opposed to packaging that simulates a wide body shape. Furthermore, we show that the effect of slim package shape on consumer behaviour is goal dependent. Whereas simulation of a slim (vs. wide) body shape increases choice likelihood and product attitude when consumers have a health-relevant shopping goal, packaging shape does not affect these outcomes when consumers have a hedonic shopping goal. In Study 3, we adopt a realistic shopping paradigm using a shelf with authentic products, and find that a slim (as opposed to wide) package shape increases on-shelf product recognition and increases product attitude for healthy products. We discuss results and implications regarding product positioning and the packaging design process. Copyright © 2016 Elsevier Ltd. All rights reserved.

  18. Lithium Insertion in LixMn2O4, 0

    DEFF Research Database (Denmark)

    West, Keld; Zachau-Christiansen, Birgit; Skaarup, Steen

    1996-01-01

    The electrochemical lithium insertion properties of highly crystalline LixMn2O4 are investigated in the approximate lithium insertion range 0 ... of the lithium insertion/extraction reactions is better at the higher voltages (versus Li/Li+), and particularly at the 4 V plateau. The lithium insertion/extraction reaction at the 1 V plateau although essentially reversible is associated with a significant voltage hysteresis....

  19. ACTIVE PACKAGING SYSTEM FOR MEAT AND MEAT PRODUCTS

    Directory of Open Access Journals (Sweden)

    Adriana Pavelková

    2012-10-01

    Full Text Available In the recent past, food packaging was used to enable marketing of products and to provide passive protection against environmental contaminations or influences that affect the shelf life of the products. However, unlike traditional packaging, which must be totally inert, active packaging is designed to interact with the contents and/or the surrounding environment. Interest in the use of active packaging systems for meat and meat products has increased in recent years. Active packaging systems are developed with the goal of extending shelf life for foods and increasing the period of time that the food is high quality. Developments in active packaging have led to advances in many areas, including delayed oxidation and controlled respiration rate, microbial growth, and moisture migration. Active packaging technologies include some physical, chemical, or biological action which changes interactions between a package, product, and/or headspace of the package in order to get a desired outcome. Active packaging systems discussed include oxygen scavengers, carbon dioxide scavengers and emitters, moisture control agents, flavour/odour absorbers and releasers  and antimicrobial packaging technologies. Active packaging is typically found in two types of systems; sachets and pads which are placed inside of packages, and active ingredients that are incorporated directly into packaging materials.  Recognition of the benefits of active packaging technologies by the food industry, development of economically viable packaging systems and increased consumer acceptance is necessary for commercial realisation of these packaging technologies.doi:10.5219/205

  20. Power Electronics Packaging Reliability | Transportation Research | NREL

    Science.gov (United States)

    Packaging Reliability Power Electronics Packaging Reliability A photo of a piece of power electronics laboratory equipment. NREL power electronics packaging reliability research investigates the electronics packaging around a semiconductor switching device determines the electrical, thermal, and