WorldWideScience

Sample records for sea-viewing wide field-of-view

  1. Chromophoric Dissolved Organic Matter and Dissolved Organic Carbon from Sea-Viewing Wide Field-of-View Sensor (SeaWiFS), Moderate Resolution Imaging Spectroradiometer (MODIS) and MERIS Sensors: Case Study for the Northern Gulf of Mexico

    OpenAIRE

    Blake A. Schaeffer; Thomas S. Bianchi; Eurico J. D'Sa; Christopher L. Osburn; Nazanin Chaichi Tehrani

    2013-01-01

    Empirical band ratio algorithms for the estimation of colored dissolved organic matter (CDOM) and dissolved organic carbon (DOC) for Sea-viewing Wide Field-of-view Sensor (SeaWiFS), Moderate Resolution Imaging Spectroradiometer (MODIS) and MERIS ocean color sensors were assessed and developed for the northern Gulf of Mexico. Match-ups between in situ measurements of CDOM absorption coefficients at 412 nm (aCDOM(412)) with that derived from SeaWiFS were examined using two previously reported r...

  2. Chromophoric Dissolved Organic Matter and Dissolved Organic Carbon from Sea-Viewing Wide Field-of-View Sensor (SeaWiFS, Moderate Resolution Imaging Spectroradiometer (MODIS and MERIS Sensors: Case Study for the Northern Gulf of Mexico

    Directory of Open Access Journals (Sweden)

    Blake A. Schaeffer

    2013-03-01

    Full Text Available Empirical band ratio algorithms for the estimation of colored dissolved organic matter (CDOM and dissolved organic carbon (DOC for Sea-viewing Wide Field-of-view Sensor (SeaWiFS, Moderate Resolution Imaging Spectroradiometer (MODIS and MERIS ocean color sensors were assessed and developed for the northern Gulf of Mexico. Match-ups between in situ measurements of CDOM absorption coefficients at 412 nm (aCDOM(412 with that derived from SeaWiFS were examined using two previously reported reflectance band ratio algorithms. Results indicate better performance using the Rrs(510/Rrs(555 (Bias = −0.045; RMSE = 0.23; SI = 0.49, and R2 = 0.66 than the Rrs(490/Rrs(555 reflectance band ratio algorithm. Further, a comparison of aCDOM(412 retrievals using the Rrs(488/Rrs(555 for MODIS and Rrs(510/Rrs(560 for MERIS reflectance band ratios revealed better CDOM retrievals with MERIS data. Since DOC cannot be measured directly by remote sensors, CDOM as the colored component of DOC is utilized as a proxy to estimate DOC remotely. A seasonal relationship between CDOM and DOC was established for the summer and spring-winter with high correlation for both periods (R2~0.9. Seasonal band ratio empirical algorithms to estimate DOC were thus developed using the relationships between CDOM-Rrs and seasonal CDOM-DOC for SeaWiFS, MODIS and MERIS. Results of match-up comparisons revealed DOC estimates by both MODIS and MERIS to be relatively more accurate during summer time, while both of them underestimated DOC during spring-winter time. A better DOC estimate from MERIS in comparison to MODIS in spring-winter could be attributed to its similarity with the SeaWiFS band ratio CDOM algorithm.

  3. Lensless imaging for wide field of view

    Science.gov (United States)

    Nagahara, Hajime; Yagi, Yasushi

    2015-02-01

    It is desirable to engineer a small camera with a wide field of view (FOV) because of current developments in the field of wearable cameras and computing products, such as action cameras and Google Glass. However, typical approaches for achieving wide FOV, such as attaching a fisheye lens and convex mirrors, require a trade-off between optics size and the FOV. We propose camera optics that achieve a wide FOV, and are at the same time small and lightweight. The proposed optics are a completely lensless and catoptric design. They contain four mirrors, two for wide viewing, and two for focusing the image on the camera sensor. The proposed optics are simple and can be simply miniaturized, since we use only mirrors for the proposed optics and the optics are not susceptible to chromatic aberration. We have implemented the prototype optics of our lensless concept. We have attached the optics to commercial charge-coupled device/complementary metal oxide semiconductor cameras and conducted experiments to evaluate the feasibility of our proposed optics.

  4. Optical system design of CCD star sensor with large aperture and wide field of view

    Science.gov (United States)

    Wang, Chao; Jiang, Lun; Li, Ying-chao; Liu, Zhuang

    2017-10-01

    The star sensor is one of the sensors which are used to determine the spatial attitude of the space vehicle. An optical system of star sensor with large aperture and wide field of view was designed in this paper. The effective focal length of the optics was 16mm, and the F-number is 1.2, the field of view of the optical system is 20°.The working spectrum is 500 to 800 nanometer. The lens system selects a similar complicated Petzval structure and special glass-couple, and get a high imaging quality in the whole spectrum range. For each field-of-view point, the values of the modulation transfer function at 50 cycles/mm is higher than 0.3. On the detecting plane, the encircled energy in a circle of 14μm diameter could be up to 80% of the total energy. In the whole range of the field of view, the dispersion spot diameter in the imaging plane is no larger than 13μm. The full field distortion was less than 0.1%, which was helpful to obtain the accurate location of the reference star through the picture gotten by the star sensor. The lateral chromatic aberration is less than 2μm in the whole spectrum range.

  5. Wide Field-of-View Soft X-Ray Imaging for Solar Wind-Magnetosphere Interactions

    Science.gov (United States)

    Walsh, B. M.; Collier, M. R.; Kuntz, K. D.; Porter, F. S.; Sibeck, D. G.; Snowden, S. L.; Carter, J. A.; Collado-Vega, Y.; Connor, H. K.; Cravens, T. E.; hide

    2016-01-01

    Soft X-ray imagers can be used to study the mesoscale and macroscale density structures that occur whenever and wherever the solar wind encounters neutral atoms at comets, the Moon, and both magnetized and unmagnetized planets. Charge exchange between high charge state solar wind ions and exospheric neutrals results in the isotropic emission of soft X-ray photons with energies from 0.1 to 2.0 keV. At Earth, this process occurs primarily within the magnetosheath and cusps. Through providing a global view, wide field-of-view imaging can determine the significance of the various proposed solar wind-magnetosphere interaction mechanisms by evaluating their global extent and occurrence patterns. A summary of wide field-of-view (several to tens of degrees) soft X-ray imaging is provided including slumped micropore microchannel reflectors, simulated images, and recent flight results.

  6. Wide field-of-view dual-band multispectral muzzle flash detection

    Science.gov (United States)

    Montoya, J.; Melchor, J.; Spiliotis, P.; Taplin, L.

    2013-06-01

    Sensor technologies are undergoing revolutionary advances, as seen in the rapid growth of multispectral methodologies. Increases in spatial, spectral, and temporal resolution, and in breadth of spectral coverage, render feasible sensors that function with unprecedented performance. A system was developed that addresses many of the key hardware requirements for a practical dual-band multispectral acquisition system, including wide field of view and spectral/temporal shift between dual bands. The system was designed using a novel dichroic beam splitter and dual band-pass filter configuration that creates two side-by-side images of a scene on a single sensor. A high-speed CMOS sensor was used to simultaneously capture data from the entire scene in both spectral bands using a short focal-length lens that provided a wide field-of-view. The beam-splitter components were arranged such that the two images were maintained in optical alignment and real-time intra-band processing could be carried out using only simple arithmetic on the image halves. An experiment related to limitations of the system to address multispectral detection requirements was performed. This characterized the system's low spectral variation across its wide field of view. This paper provides lessons learned on the general limitation of key hardware components required for multispectral muzzle flash detection, using the system as a hardware example combined with simulated multispectral muzzle flash and background signatures.

  7. Design, manufacturing and testing of a four-mirror telescope with a wide field of view

    Science.gov (United States)

    Gloesener, P.; Wolfs, F.; Lemagne, F.; Cola, M.; Flebus, C.; Blanchard, G.; Kirschner, V.

    2017-11-01

    Regarding Earth observation missions, it has become unnecessary to point out the importance of making available wide field of view optical instruments for the purpose of spectral imaging. Taking advantage of the pushbroom instrument concept with its linear field across the on-ground track, it is in particular relevant to consider front-end optical configurations that involve an all-reflective system presenting inherent and dedicated advantages such as achromaticity, unobscuration and compactness, while ensuring the required image quality over the whole field. The attractiveness of the concept must be balanced with respect to the state-of-the-art mirror manufacturing technologies as the need for fast, broadband and wide field systems increases the constraints put on the feasibility of each individual component. As part of an ESTEC contract, AMOS designed, manufactured and tested a breadboard of a four-mirror wide field telescope for typical Earth observation superspectral missions. The initial purpose of the development was to assess the feasibility of a telecentric spaceborne three-mirror system covering an unobscured rectangular field of view of 26 degrees across track (ACT) by 6 degrees along track (ALT) with a f-number of 3.5 and a focal length of 500 mm and presenting an overall image quality better than 100 nm RMS wavefront error within the whole field.

  8. Astronomical Orientation Method Based on Lunar Observations Utilizing Super Wide Field of View

    Directory of Open Access Journals (Sweden)

    PU Junyu

    2018-04-01

    Full Text Available In this paper,astronomical orientation is achieved by observing the moon utilizing camera with super wide field of view,and formulae are deduced in detail.An experiment based on real observations verified the stability of the method.In this experiment,after 15 minutes' tracking shoots,the internal precision could be superior to ±7.5" and the external precision could approximately reach ±20".This camera-based method for astronomical orientation can change the traditional mode (aiming by human eye based on theodolite,thus lowering the requirements for operator's skill to some extent.Furthermore,camera with super wide field of view can realize the function of continuous tracking shoots on the moon without complicated servo control devices.Considering the similar existence of gravity on the moon and the earth's phase change when observed from the moon,once the technology of self-leveling is developed,this method can be extended to orientation for lunar rover by shooting the earth.

  9. Wide field of view common-path lateral-shearing digital holographic interference microscope.

    Science.gov (United States)

    Vora, Priyanka; Trivedi, Vismay; Mahajan, Swapnil; Patel, Nimit; Joglekar, Mugdha; Chhaniwal, Vani; Moradi, Ali-Reza; Javidi, Bahram; Anand, Arun

    2017-12-01

    Quantitative three-dimensional (3-D) imaging of living cells provides important information about the cell morphology and its time variation. Off-axis, digital holographic interference microscopy is an ideal tool for 3-D imaging, parameter extraction, and classification of living cells. Two-beam digital holographic microscopes, which are usually employed, provide high-quality 3-D images of micro-objects, albeit with lower temporal stability. Common-path digital holographic geometries, in which the reference beam is derived from the object beam, provide higher temporal stability along with high-quality 3-D images. Self-referencing geometry is the simplest of the common-path techniques, in which a portion of the object beam itself acts as the reference, leading to compact setups using fewer optical elements. However, it has reduced field of view, and the reference may contain object information. Here, we describe the development of a common-path digital holographic microscope, employing a shearing plate and converting one of the beams into a separate reference by employing a pin-hole. The setup is as compact as self-referencing geometry, while providing field of view as wide as that of a two-beam microscope. The microscope is tested by imaging and quantifying the morphology and dynamics of human erythrocytes. (2017) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE).

  10. Wide field of view CT and acromioclavicular joint instability: A technical innovation.

    Science.gov (United States)

    Dyer, David R; Troupis, John M; Kamali Moaveni, Afshin

    2015-06-01

    A 21-year-old female with a traumatic shoulder injury is investigated and managed for symptoms relating to this injury. Pathology at the acromioclavicular joint is detected clinically; however, clinical examination and multiple imaging modalities do not reach a unified diagnosis on the grading of this acromioclavicular joint injury. When management appropriate to that suggested injury grading fail to help the patient's symptoms, further investigation methods were utilised. Wide field of view, dynamic CT (4D CT) is conducted on the patient's affected shoulder using a 320 × 0.5 mm detector multislice CT. Scans were conducted with a static table as the patient completed three movements of the affected shoulder. Capturing multiple data sets per second over a z-axis of 16 cm, measurements of the acromioclavicular joint were made, to show dynamic changes at the joint. Acromioclavicular (AC) joint translations were witnessed in three planes (a previously unrecognised pathology in the grading of acromioclavicular joint injuries). Translation in multiple planes was also not evident on careful clinical examination of this patient. AC joint width, anterior-posterior translation, superior-inferior translation and coracoclavicular width were measured with planar reconstructions while volume-rendered images and dynamic sequences aiding visual understanding of the pathology. Wide field of view dynamic CT (4D CT) is an accurate and quick modality to diagnose complex acromioclavicular joint injury. It provides dynamic information that no other modality can; 4D CT shows future benefits for clinical approach to diagnosis and management of acromioclavicular joint injury, and other musculoskeletal pathologies. © 2015 The Royal Australian and New Zealand College of Radiologists.

  11. Improved iris localization by using wide and narrow field of view cameras for iris recognition

    Science.gov (United States)

    Kim, Yeong Gon; Shin, Kwang Yong; Park, Kang Ryoung

    2013-10-01

    Biometrics is a method of identifying individuals by their physiological or behavioral characteristics. Among other biometric identifiers, iris recognition has been widely used for various applications that require a high level of security. When a conventional iris recognition camera is used, the size and position of the iris region in a captured image vary according to the X, Y positions of a user's eye and the Z distance between a user and the camera. Therefore, the searching area of the iris detection algorithm is increased, which can inevitably decrease both the detection speed and accuracy. To solve these problems, we propose a new method of iris localization that uses wide field of view (WFOV) and narrow field of view (NFOV) cameras. Our study is new as compared to previous studies in the following four ways. First, the device used in our research acquires three images, one each of the face and both irises, using one WFOV and two NFOV cameras simultaneously. The relation between the WFOV and NFOV cameras is determined by simple geometric transformation without complex calibration. Second, the Z distance (between a user's eye and the iris camera) is estimated based on the iris size in the WFOV image and anthropometric data of the size of the human iris. Third, the accuracy of the geometric transformation between the WFOV and NFOV cameras is enhanced by using multiple matrices of the transformation according to the Z distance. Fourth, the searching region for iris localization in the NFOV image is significantly reduced based on the detected iris region in the WFOV image and the matrix of geometric transformation corresponding to the estimated Z distance. Experimental results showed that the performance of the proposed iris localization method is better than that of conventional methods in terms of accuracy and processing time.

  12. Wide-band acousto-optic deflectors for large field of view two-photon microscope.

    Science.gov (United States)

    Jiang, Runhua; Zhou, Zhenqiao; Lv, Xiaohua; Zeng, Shaoqun

    2012-04-01

    Acousto-optic deflector (AOD) is an attractive scanner for two-photon microscopy because it can provide fast and versatile laser scanning and does not involve any mechanical movements. However, due to the small scan range of available AOD, the field of view (FOV) of the AOD-based microscope is typically smaller than that of the conventional galvanometer-based microscope. Here, we developed a novel wide-band AOD to enlarge the scan angle. Considering the maximum acceptable acoustic attenuation in the acousto-optic crystal, relatively lower operating frequencies and moderate aperture were adopted. The custom AOD was able to provide 60 MHz 3-dB bandwidth and 80% peak diffraction efficiency at 840 nm wavelength. Based on a pair of such AOD, a large FOV two-photon microscope was built with a FOV up to 418.5 μm (40× objective). The spatiotemporal dispersion was compensated simultaneously with a single custom-made prism. By means of dynamic power modulation, the variation of laser intensity within the FOV was reduced below 5%. The lateral and axial resolution of the system were 0.58-2.12 μm and 2.17-3.07 μm, respectively. Pollen grain images acquired by this system were presented to demonstrate the imaging capability at different positions across the entire FOV. © 2012 American Institute of Physics

  13. PSF Estimation of Space-Variant Ultra-Wide Field of View Imaging Systems

    Directory of Open Access Journals (Sweden)

    Petr Janout

    2017-02-01

    Full Text Available Ultra-wide-field of view (UWFOV imaging systems are affected by various aberrations, most of which are highly angle-dependent. A description of UWFOV imaging systems, such as microscopy optics, security camera systems and other special space-variant imaging systems, is a difficult task that can be achieved by estimating the Point Spread Function (PSF of the system. This paper proposes a novel method for modeling the space-variant PSF of an imaging system using the Zernike polynomials wavefront description. The PSF estimation algorithm is based on obtaining field-dependent expansion coefficients of the Zernike polynomials by fitting real image data of the analyzed imaging system using an iterative approach in an initial estimate of the fitting parameters to ensure convergence robustness. The method is promising as an alternative to the standard approach based on Shack–Hartmann interferometry, since the estimate of the aberration coefficients is processed directly in the image plane. This approach is tested on simulated and laboratory-acquired image data that generally show good agreement. The resulting data are compared with the results of other modeling methods. The proposed PSF estimation method provides around 5% accuracy of the optical system model.

  14. Refined adaptive optics simulation with wide field of view for the E-ELT

    International Nuclear Information System (INIS)

    Chebbo, Manal

    2012-01-01

    Refined simulation tools for wide field AO systems (such as MOAO, MCAO or LTAO) on ELTs present new challenges. Increasing the number of degrees of freedom (scales as the square of the telescope diameter) makes the standard simulation's codes useless due to the huge number of operations to be performed at each step of the Adaptive Optics (AO) loop process. This computational burden requires new approaches in the computation of the DM voltages from WFS data. The classical matrix inversion and the matrix vector multiplication have to be replaced by a cleverer iterative resolution of the Least Square or Minimum Mean Square Error criterion (based on sparse matrices approaches). Moreover, for this new generation of AO systems, concepts themselves will become more complex: data fusion coming from multiple Laser and Natural Guide Stars (LGS / NGS) will have to be optimized, mirrors covering all the field of view associated to dedicated mirrors inside the scientific instrument itself will have to be coupled using split or integrated tomography schemes, differential pupil or/and field rotations will have to be considered, etc. All these new entries should be carefully simulated, analysed and quantified in terms of performance before any implementation in AO systems. For those reasons I developed, in collaboration with the ONERA, a full simulation code, based on iterative solution of linear systems with many parameters (use of sparse matrices). On this basis, I introduced new concepts of filtering and data fusion (LGS / NGS) to effectively manage modes such as tip, tilt and defocus in the entire process of tomographic reconstruction. The code will also eventually help to develop and test complex control laws (Multi-DM and multi-field) who have to manage a combination of adaptive telescope and post-focal instrument including dedicated deformable mirrors. The first application of this simulation tool has been studied in the framework of the EAGLE multi-object spectrograph

  15. EMBRACE@Nançay: an ultra wide field of view prototype for the SKA

    International Nuclear Information System (INIS)

    Torchinsky, S.A.; Censier, B.; Serylak, M.; Renaud, P.; Taffoureau, C.; Olofsson, A.O.H.; Karastergiou, A.

    2015-01-01

    A revolution in radio receiving technology is underway with the development of densely packed phased arrays for radio astronomy. This technology can provide an exceptionally large field of view, while at the same time sampling the sky with high angular resolution. Such an instrument, with a field of view of over 100 square degrees, is ideal for performing fast, all-sky, surveys, such as the ''intensity mapping'' experiment to measure the signature of Baryonic Acoustic Oscillations in the HI mass distribution at cosmological redshifts. The SKA, built with this technology, will be able to do a billion galaxy survey. I will present a very brief introduction to radio interferometry, as well as an overview of the Square Kilometre Array project. This will be followed by a description of the EMBRACE prototype and a discussion of results and future plans

  16. Fiber-Coupled Wide Field of View Optical Receiver for High Speed Space Communication

    Science.gov (United States)

    Suddath, Shannon N.

    Research groups at NASA Glenn Research Center are interested in improving data rates on the International Space Station (ISS) using a free-space optical (FSO) link. However, known flexure of the ISS structure is expected to cause misalignment of the FSO link. Passive-control designs for mitigating misalignment are under investigation, including using a fiber-bundle for improved field of view. The designs must overcome the obstacle of coupling directly to fiber, rather than a photodetector, as NASA will maintain the use of small form-factor pluggable optical transceivers (SFPs) in the ISS network. In this thesis, a bundle-based receiver capable of coupling directly to fiber is designed, simulated, and tested in lab. Two 3-lens systems were evaluated for power performance in the lab, one with a 20 mm focal length aspheric lens and the other with a 50 mm focal length aspheric lens. The maximum output power achieved was 8 muW.

  17. New in-flight calibration adjustment of the Nimbus 6 and 7 earth radiation budget wide field of view radiometers

    Science.gov (United States)

    Kyle, H. L.; House, F. B.; Ardanuy, P. E.; Jacobowitz, H.; Maschhoff, R. H.; Hickey, J. R.

    1984-01-01

    In-flight calibration adjustments are developed to process data obtained from the wide-field-of-view channels of Nimbus-6 and Nimbus-7 after the failure of the Nimbus-7 longwave scanner on June 22, 1980. The sensor characteristics are investigated; the satellite environment is examined in detail; and algorithms are constructed to correct for long-term sensor-response changes, on/off-cycle thermal transients, and filter-dome absorption of longwave radiation. Data and results are presented in graphs and tables, including comparisons of the old and new algorithms.

  18. Multimode simulations of a wide field of view double-Fourier far-infrared spatio-spectral interferometer

    Science.gov (United States)

    Bracken, Colm P.; Lightfoot, John; O'Sullivan, Creidhe; Murphy, J. Anthony; Donohoe, Anthony; Savini, Giorgio; Juanola-Parramon, Roser; The Fisica Consortium, On Behalf Of

    2018-01-01

    In the absence of 50-m class space-based observatories, subarcsecond astronomy spanning the full far-infrared wavelength range will require space-based long-baseline interferometry. The long baselines of up to tens of meters are necessary to achieve subarcsecond resolution demanded by science goals. Also, practical observing times command a field of view toward an arcminute (1‧) or so, not achievable with a single on-axis coherent detector. This paper is concerned with an application of an end-to-end instrument simulator PyFIInS, developed as part of the FISICA project under funding from the European Commission's seventh Framework Programme for Research and Technological Development (FP7). Predicted results of wide field of view spatio-spectral interferometry through simulations of a long-baseline, double-Fourier, far-infrared interferometer concept are presented and analyzed. It is shown how such an interferometer, illuminated by a multimode detector can recover a large field of view at subarcsecond angular resolution, resulting in similar image quality as that achieved by illuminating the system with an array of coherent detectors. Through careful analysis, the importance of accounting for the correct number of higher-order optical modes is demonstrated, as well as accounting for both orthogonal polarizations. Given that it is very difficult to manufacture waveguide and feed structures at sub-mm wavelengths, the larger multimode design is recommended over the array of smaller single mode detectors. A brief note is provided in the conclusion of this paper addressing a more elegant solution to modeling far-infrared interferometers, which holds promise for improving the computational efficiency of the simulations presented here.

  19. Optical system design with wide field of view and high resolution based on monocentric multi-scale construction

    Science.gov (United States)

    Wang, Fang; Wang, Hu; Xiao, Nan; Shen, Yang; Xue, Yaoke

    2018-03-01

    With the development of related technology gradually mature in the field of optoelectronic information, it is a great demand to design an optical system with high resolution and wide field of view(FOV). However, as it is illustrated in conventional Applied Optics, there is a contradiction between these two characteristics. Namely, the FOV and imaging resolution are limited by each other. Here, based on the study of typical wide-FOV optical system design, we propose the monocentric multi-scale system design method to solve this problem. Consisting of a concentric spherical lens and a series of micro-lens array, this system has effective improvement on its imaging quality. As an example, we designed a typical imaging system, which has a focal length of 35mm and a instantaneous field angle of 14.7", as well as the FOV set to be 120°. By analyzing the imaging quality, we demonstrate that in different FOV, all the values of MTF at 200lp/mm are higher than 0.4 when the sampling frequency of the Nyquist is 200lp/mm, which shows a good accordance with our design.

  20. Wide Field-of-View Fluorescence Imaging with Optical-Quality Curved Microfluidic Chamber for Absolute Cell Counting

    Directory of Open Access Journals (Sweden)

    Mohiuddin Khan Shourav

    2016-07-01

    Full Text Available Field curvature and other aberrations are encountered inevitably when designing a compact fluorescence imaging system with a simple lens. Although multiple lens elements can be used to correct most such aberrations, doing so increases system cost and complexity. Herein, we propose a wide field-of-view (FOV fluorescence imaging method with an unconventional optical-quality curved sample chamber that corrects the field curvature caused by a simple lens. Our optics simulations and proof-of-concept experiments demonstrate that a curved substrate with lens-dependent curvature can reduce greatly the distortion in an image taken with a conventional planar detector. Following the validation study, we designed a curved sample chamber that can contain a known amount of sample volume and fabricated it at reasonable cost using plastic injection molding. At a magnification factor of approximately 0.6, the curved chamber provides a clear view of approximately 119 mm2, which is approximately two times larger than the aberration-free area of a planar chamber. Remarkably, a fluorescence image of microbeads in the curved chamber exhibits almost uniform intensity over the entire field even with a simple lens imaging system, whereas the distorted boundary region has much lower brightness than the central area in the planar chamber. The absolute count of white blood cells stained with a fluorescence dye was in good agreement with that obtained by a commercially available conventional microscopy system. Hence, a wide FOV imaging system with the proposed curved sample chamber would enable us to acquire an undistorted image of a large sample volume without requiring a time-consuming scanning process in point-of-care diagnostic applications.

  1. Dynamic registration of an optical see-through HMD into a wide field-of-view rotorcraft flight simulation environment

    Science.gov (United States)

    Viertler, Franz; Hajek, Manfred

    2015-05-01

    To overcome the challenge of helicopter flight in degraded visual environments, current research considers headmounted displays with 3D-conformal (scene-linked) visual cues as most promising display technology. For pilot-in-theloop simulations with HMDs, a highly accurate registration of the augmented visual system is required. In rotorcraft flight simulators the outside visual cues are usually provided by a dome projection system, since a wide field-of-view (e.g. horizontally > 200° and vertically > 80°) is required, which can hardly be achieved with collimated viewing systems. But optical see-through HMDs do mostly not have an equivalent focus compared to the distance of the pilot's eye-point position to the curved screen, which is also dependant on head motion. Hence, a dynamic vergence correction has been implemented to avoid binocular disparity. In addition, the parallax error induced by even small translational head motions is corrected with a head-tracking system to be adjusted onto the projected screen. For this purpose, two options are presented. The correction can be achieved by rendering the view with yaw and pitch offset angles dependent on the deviating head position from the design eye-point of the spherical projection system. Furthermore, it can be solved by implementing a dynamic eye-point in the multi-channel projection system for the outside visual cues. Both options have been investigated for the integration of a binocular HMD into the Rotorcraft Simulation Environment (ROSIE) at the Technische Universitaet Muenchen. Pros and cons of both possibilities with regard on integration issues and usability in flight simulations will be discussed.

  2. Reconsidering the advantages of the three-dimensional representation of the interferometric transform for imaging with non-coplanar baselines and wide fields of view

    Science.gov (United States)

    Smith, D. M. P.; Young, A.; Davidson, D. B.

    2017-07-01

    Radio telescopes with baselines that span thousands of kilometres and with fields of view that span tens of degrees have been recently deployed, such as the Low Frequency Array, and are currently being developed, such as the Square Kilometre Array. Additionally, there are proposals for space-based instruments with all-sky imaging capabilities, such as the Orbiting Low Frequency Array. Such telescopes produce observations with three-dimensional visibility distributions and curved image domains. In most work to date, the visibility distribution has been converted to a planar form to compute the brightness map using a two-dimensional Fourier transform. The celestial sphere is faceted in order to counter pixel distortion at wide angles, with each such facet requiring a unique planar form of the visibility distribution. Under the above conditions, the computational and storage complexities of this approach can become excessive. On the other hand, when using the direct Fourier transform approach, which maintains the three-dimensional shapes of the visibility distribution and celestial sphere, the non-coplanar visibility component requires no special attention. Furthermore, as the celestial samples are placed directly on the curved surface of the celestial sphere, pixel distortion at wide angles is avoided. In this paper, a number of examples illustrate that under these conditions (very long baselines and very wide fields of view) the costs of the direct Fourier transform may be comparable to (or even lower than) methods that utilise the two-dimensional fast Fourier transform.

  3. Wide field of view computed tomography and mid carpal instability: The value of the sagittal radius–lunate–capitate axis – Preliminary experience

    Energy Technology Data Exchange (ETDEWEB)

    Repse, Stephen E., E-mail: stephrep@gmail.com [Department of Diagnostic Imaging, Monash Health, VIC (Australia); Koulouris, George, E-mail: GeorgeK@melbourneradiology.com.au [Melbourne Radiology Clinic, Ground Floor, 3-6/100 Victoria Parade, East Melbourne, VIC (Australia); Centre for Orthopaedic Research, School of Surgery, University of Western Australia, Nedlands, WA (Australia); Troupis, John M., E-mail: john.troupis@gmail.com [Department of Diagnostic Imaging & Monash Cardiovascular Research Centre, Monash Health and Department of Biomedical Radiation Sciences, Faculty of Medicine, Nursing & Health Sciences, Monash University, VIC (Australia)

    2015-05-15

    Highlights: • Unique insight into the assessment of mid carpal instability. • 4D CT using sagittal reconstructions along the radius–lunate–capitate axis. • 4D CT observations of vacuum phenomenon, trigger lunate and capitate subluxation. • Earlier recognition of mid carpal instability. - Abstract: Purpose: Dynamic four dimensional (4D) computed tomography (CT) has recently emerged as a practical method for evaluating complex functional abnormality of joints. We retrospectively analysed 4D CT studies undertaken as part of the clinical management of hand and wrist symptoms. We present our initial experience of 4D CT in the assessment of functional abnormalities of the wrist in a group of patients with mid carpal instability (MCI), specifically carpal instability non-dissociative. We aim to highlight unique features in assessment of the radius–lunate–capitate (RLC) axis which allows insight and understanding of abnormalities in function, not just morphology, which may be contributing to symptoms. Materials and methods: Wide field of view multi-detector CT scanner (320 slices, 0.5 mm detector thickness) was used to acquire bilateral continuous motion assessment in hand flexion and extension. A maximum z-axis coverage of 16 cm was available for each acquisition, and a large field of view (FOV) was used. Due to the volume acquisition during motion, reconstructions at multiple time points were undertaken. Dynamic and anatomically targeted multi-planar-reconstructions (MPRs) were then used to establish the kinematic functionality of the joint. Results: Our initial cohort of 20 patients was reviewed. Three findings were identified which were present either in isolation or in combination. These are vacuum phenomenon, triggering of the lunate and capitate subluxation. We provide 4D CT representations of each and highlight features considered of clinical importance and their significance. We also briefly discuss how the current classifications of dynamic wrist

  4. Wide field of view computed tomography and mid carpal instability: The value of the sagittal radius–lunate–capitate axis – Preliminary experience

    International Nuclear Information System (INIS)

    Repse, Stephen E.; Koulouris, George; Troupis, John M.

    2015-01-01

    Highlights: • Unique insight into the assessment of mid carpal instability. • 4D CT using sagittal reconstructions along the radius–lunate–capitate axis. • 4D CT observations of vacuum phenomenon, trigger lunate and capitate subluxation. • Earlier recognition of mid carpal instability. - Abstract: Purpose: Dynamic four dimensional (4D) computed tomography (CT) has recently emerged as a practical method for evaluating complex functional abnormality of joints. We retrospectively analysed 4D CT studies undertaken as part of the clinical management of hand and wrist symptoms. We present our initial experience of 4D CT in the assessment of functional abnormalities of the wrist in a group of patients with mid carpal instability (MCI), specifically carpal instability non-dissociative. We aim to highlight unique features in assessment of the radius–lunate–capitate (RLC) axis which allows insight and understanding of abnormalities in function, not just morphology, which may be contributing to symptoms. Materials and methods: Wide field of view multi-detector CT scanner (320 slices, 0.5 mm detector thickness) was used to acquire bilateral continuous motion assessment in hand flexion and extension. A maximum z-axis coverage of 16 cm was available for each acquisition, and a large field of view (FOV) was used. Due to the volume acquisition during motion, reconstructions at multiple time points were undertaken. Dynamic and anatomically targeted multi-planar-reconstructions (MPRs) were then used to establish the kinematic functionality of the joint. Results: Our initial cohort of 20 patients was reviewed. Three findings were identified which were present either in isolation or in combination. These are vacuum phenomenon, triggering of the lunate and capitate subluxation. We provide 4D CT representations of each and highlight features considered of clinical importance and their significance. We also briefly discuss how the current classifications of dynamic wrist

  5. 3D wide field-of-view Gabor-domain optical coherence microscopy advancing real-time in-vivo imaging and metrology

    Science.gov (United States)

    Canavesi, Cristina; Cogliati, Andrea; Hayes, Adam; Tankam, Patrice; Santhanam, Anand; Rolland, Jannick P.

    2017-02-01

    Real-time volumetric high-definition wide-field-of-view in-vivo cellular imaging requires micron-scale resolution in 3D. Compactness of the handheld device and distortion-free images with cellular resolution are also critically required for onsite use in clinical applications. By integrating a custom liquid lens-based microscope and a dual-axis MEMS scanner in a compact handheld probe, Gabor-domain optical coherence microscopy (GD-OCM) breaks the lateral resolution limit of optical coherence tomography through depth, overcoming the tradeoff between numerical aperture and depth of focus, enabling advances in biotechnology. Furthermore, distortion-free imaging with no post-processing is achieved with a compact, lightweight handheld MEMS scanner that obtained a 12-fold reduction in volume and 17-fold reduction in weight over a previous dual-mirror galvanometer-based scanner. Approaching the holy grail of medical imaging - noninvasive real-time imaging with histologic resolution - GD-OCM demonstrates invariant resolution of 2 μm throughout a volume of 1 x 1 x 0.6 mm3, acquired and visualized in less than 2 minutes with parallel processing on graphics processing units. Results on the metrology of manufactured materials and imaging of human tissue with GD-OCM are presented.

  6. Phenology-based Spartina alterniflora mapping in coastal wetland of the Yangtze Estuary using time series of GaoFen satellite no. 1 wide field of view imagery

    Science.gov (United States)

    Ai, Jinquan; Gao, Wei; Gao, Zhiqiang; Shi, Runhe; Zhang, Chao

    2017-04-01

    Spartina alterniflora is an aggressive invasive plant species that replaces native species, changes the structure and function of the ecosystem across coastal wetlands in China, and is thus a major conservation concern. Mapping the spread of its invasion is a necessary first step for the implementation of effective ecological management strategies. The performance of a phenology-based approach for S. alterniflora mapping is explored in the coastal wetland of the Yangtze Estuary using a time series of GaoFen satellite no. 1 wide field of view camera (GF-1 WFV) imagery. First, a time series of the normalized difference vegetation index (NDVI) was constructed to evaluate the phenology of S. alterniflora. Two phenological stages (the senescence stage from November to mid-December and the green-up stage from late April to May) were determined as important for S. alterniflora detection in the study area based on NDVI temporal profiles, spectral reflectance curves of S. alterniflora and its coexistent species, and field surveys. Three phenology feature sets representing three major phenology-based detection strategies were then compared to map S. alterniflora: (1) the single-date imagery acquired within the optimal phenological window, (2) the multitemporal imagery, including four images from the two important phenological windows, and (3) the monthly NDVI time series imagery. Support vector machines and maximum likelihood classifiers were applied on each phenology feature set at different training sample sizes. For all phenology feature sets, the overall results were produced consistently with high mapping accuracies under sufficient training samples sizes, although significantly improved classification accuracies (10%) were obtained when the monthly NDVI time series imagery was employed. The optimal single-date imagery had the lowest accuracies of all detection strategies. The multitemporal analysis demonstrated little reduction in the overall accuracy compared with the

  7. Standoff Laser-Induced Breakdown Spectroscopy (LIBS) Using a Miniature Wide Field of View Spatial Heterodyne Spectrometer with Sub-Microsteradian Collection Optics.

    Science.gov (United States)

    Barnett, Patrick D; Lamsal, Nirmal; Angel, S Michael

    2017-04-01

    A spatial heterodyne spectrometer (SHS) is described for standoff laser-induced breakdown spectroscopy (LIBS) measurements. The spatial heterodyne LIBS spectrometer (SHLS) is a diffraction grating based interferometer with no moving parts that offers a very large field of view, high light throughput, and high spectral resolution in a small package. The field of view of the SHLS spectrometer is shown to be ∼1° in standoff LIBS measurements. In the SHLS system described here, the collection aperture was defined by the 10 mm diffraction gratings in the SHS and standoff LIBS measurements were made up to 20 m with no additional collection optics, corresponding to a collection solid angle of 0.2 μsr, or f/2000, and also using a small telescope to increase the collection efficiency. The use of a microphone was demonstrated to rapidly optimize laser focus for 20 m standoff LIBS measurements.

  8. Compact akinetic swept source optical coherence tomography angiography at 1060 nm supporting a wide field of view and adaptive optics imaging modes of the posterior eye.

    Science.gov (United States)

    Salas, Matthias; Augustin, Marco; Felberer, Franz; Wartak, Andreas; Laslandes, Marie; Ginner, Laurin; Niederleithner, Michael; Ensher, Jason; Minneman, Michael P; Leitgeb, Rainer A; Drexler, Wolfgang; Levecq, Xavier; Schmidt-Erfurth, Ursula; Pircher, Michael

    2018-04-01

    Imaging of the human retina with high resolution is an essential step towards improved diagnosis and treatment control. In this paper, we introduce a compact, clinically user-friendly instrument based on swept source optical coherence tomography (SS-OCT). A key feature of the system is the realization of two different operation modes. The first operation mode is similar to conventional OCT imaging and provides large field of view (FoV) images (up to 45° × 30°) of the human retina and choroid with standard resolution. The second operation mode enables it to optically zoom into regions of interest with high transverse resolution using adaptive optics (AO). The FoV of this second operation mode (AO-OCT mode) is 3.0° × 2.8° and enables the visualization of individual retinal cells such as cone photoreceptors or choriocapillaris. The OCT engine is based on an akinetic swept source at 1060 nm and provides an A-scan rate of 200 kHz. Structural as well as angiographic information can be retrieved from the retina and choroid in both operational modes. The capabilities of the prototype are demonstrated in healthy and diseased eyes.

  9. Full-color wide field-of-view holographic helmet-mounted display for pilot/vehicle interface development and human factors studies

    Science.gov (United States)

    Burley, James R., II; LaRussa, Joseph A.

    1990-10-01

    A Helmet-Mounted Display (HMD) which utilizes highly efficient trichromatic holographic elements has been designed to support pilot vechicle interface development and human factors studies at the NASA-Langley Research Center. While the optics are fully color corrected, the miniature CRT's are monochromatic. This design provides an upgrade path to full-color when miniature display technology matures to color. The optical design conforms to the helmet shape and provides a 50 degree field-of-view (FOV) to each eye. Built-in adjustments allow each ocular to be independently moved so that the overall horizontal FOV may be varied from 50 degrees to 100 degrees with a corresponding change in the stereo overlap region. The helmet design and interpupillary adjustment allow for the 5th through 95th percentile male and female wearer. Total head-borne weight is approximately 4.2 pounds. The high-resolution monochromatic CRTs are driven by a set of multisync electronics with a maximum video bandwidth of 88 Mhz and supports bith raster and stroke modes. The electronics are designed to be compatiable with the Silicon Graphics IRIS 4D graphics workstations and the ADAGE 340 stroke graphics computer. A Polhemus magnetic tracking device is used to determine the helmet line-of-sight. The helmet will be used to develop innovative new display concepts for the F- 1 8 High-Alpha Research Vehicle (HARV) which make use of the unique display properties of the HMD. Pictorial displays, which convey the appropriate information intuitively, are envisioned. Human factors studies are also planned to evaluate the utility of stereopsis and determine the FOV requirements for different tasks. Concepts proven in the simulator will be carried to flight test in 1993 with a lighter weight, "hardened" version of this HMD design.

  10. Tunable Reflective Spatial Heterodyne Spectrometer: A Technique for High Resolving Power, Wide Field Of View Observation Of Diffuse Emission Line Sources

    Science.gov (United States)

    Hosseini, Seyedeh Sona

    The purpose of this dissertation is to discuss the need for new technology in broadband high-resolution spectroscopy based on the emerging technique of Spatial Heterodyne Spectroscopy (SHS) and to propose new solutions that should enhance and generalize this technology to other fields. Spectroscopy is a proven tool for determining compositional and other properties of remote objects. Narrow band imaging and low resolving spectroscopic measurements provide information about composition, photochemical evolution, energy distribution and density. The extension to high resolving power provides further access to temperature, velocity, isotopic ratios, separation of blended sources, and opacity effects. In current high resolving power devices, the drawback of high-resolution spectroscopy is bound to the instrumental limitations of lower throughput, the necessity of small entrance apertures, sensitivity, field of view, and large physical instrumental size. These limitations quickly become handicapping for observation of faint and/or extended targets and for spacecraft encounters. A technique with promise for the study of faint and extended sources at high resolving power is the reflective format of the Spatial Heterodyne Spectrometer (SHS). SHS instruments are compact and naturally tailored for both high etendue (defined in section 2.2.5) and high resolving power. In contrast, to achieve similar spectral grasp, grating spectrometers require large telescopes. For reference, SHS is a cyclical interferometer that produces Fizeau fringe pattern for all other wavelengths except the tuned wavelength. The large etendue obtained by SHS instruments makes them ideal for observations of extended, low surface brightness, isolated emission line sources, while their intrinsically high spectral resolution enables one to study the dynamical and physical properties described above. This document contains four chapters. Chapter 1, introduces a class of scientific targets that formerly have

  11. Invited Article: First flight in space of a wide-field-of-view soft x-ray imager using lobster-eye optics: Instrument description and initial flight results.

    Science.gov (United States)

    Collier, Michael R; Porter, F Scott; Sibeck, David G; Carter, Jenny A; Chiao, Meng P; Chornay, Dennis J; Cravens, Thomas E; Galeazzi, Massimiliano; Keller, John W; Koutroumpa, Dimitra; Kujawski, Joseph; Kuntz, Kip; Read, Andy M; Robertson, Ina P; Sembay, Steve; Snowden, Steven L; Thomas, Nicholas; Uprety, Youaraj; Walsh, Brian M

    2015-07-01

    We describe the development, launch into space, and initial results from a prototype wide field-of-view soft X-ray imager that employs lobster-eye optics and targets heliophysics, planetary, and astrophysics science. The sheath transport observer for the redistribution of mass is the first instrument using this type of optics launched into space and provides proof-of-concept for future flight instruments capable of imaging structures such as the terrestrial cusp, the entire dayside magnetosheath from outside the magnetosphere, comets, the Moon, and the solar wind interaction with planetary bodies like Venus and Mars [Kuntz et al., Astrophys. J. (in press)].

  12. Useful field of view test.

    Science.gov (United States)

    Wood, Joanne M; Owsley, Cynthia

    2014-01-01

    The useful field of view test was developed to reflect the visual difficulties that older adults experience with everyday tasks. Importantly, the useful field of view test (UFOV) is one of the most extensively researched and promising predictor tests for a range of driving outcomes measures, including driving ability and crash risk as well as other everyday tasks. Currently available commercial versions of the test can be administered using personal computers; these measure the speed of visual processing for rapid detection and localization of targets under conditions of divided visual attention and in the presence and absence of visual clutter. The test is believed to assess higher-order cognitive abilities, but performance also relies on visual sensory function because in order for targets to be attended to, they must be visible. The format of the UFOV has been modified over the years; the original version estimated the spatial extent of useful field of view, while the latest version measures visual processing speed. While deficits in the useful field of view are associated with functional impairments in everyday activities in older adults, there is also emerging evidence from several research groups that improvements in visual processing speed can be achieved through training. These improvements have been shown to reduce crash risk, and can have a positive impact on health and functional well-being, with the potential to increase the mobility and hence the independence of older adults. © 2014 S. Karger AG, Basel

  13. Nimbus 7 earth radiation budget wide field of view climate data set improvement. II - Deconvolution of earth radiation budget products and consideration of 1982-1983 El Nino event

    Science.gov (United States)

    Ardanuy, Phillip E.; Hucek, Richard R.; Groveman, Brian S.; Kyle, H. Lee

    1987-01-01

    A deconvolution technique is employed that permits recovery of daily averaged earth radiation budget (ERB) parameters at the top of the atmosphere from a set of the Nimbus 7 ERB wide field of view (WFOV) measurements. Improvements in both the spatial resolution of the resultant fields and in the fidelity of the time averages is obtained. The algorithm is evaluated on a set of months during the period 1980-1983. The albedo, outgoing long-wave radiation, and net radiation parameters are analyzed. The amplitude and phase of the quasi-stationary patterns that appear in the spatially deconvolved fields describe the radiation budget components for 'normal' as well as the El Nino/Southern Oscillation (ENSO) episode years. They delineate the seasonal development of large-scale features inherent in the earth's radiation budget as well as the natural variability of interannual differences. These features are underscored by the powerful emergence of the 1982-1983 ENSO event in the fields displayed. The conclusion is that with this type of resolution enhancement, WFOV radiometers provide a useful tool for the observation of the contemporary climate and its variability.

  14. SeaTrack: Ground station orbit prediction and planning software for sea-viewing satellites

    Science.gov (United States)

    Lambert, Kenneth S.; Gregg, Watson W.; Hoisington, Charles M.; Patt, Frederick S.

    1993-01-01

    An orbit prediction software package (Sea Track) was designed to assist High Resolution Picture Transmission (HRPT) stations in the acquisition of direct broadcast data from sea-viewing spacecraft. Such spacecraft will be common in the near future, with the launch of the Sea viewing Wide Field-of-view Sensor (SeaWiFS) in 1994, along with the continued Advanced Very High Resolution Radiometer (AVHRR) series on NOAA platforms. The Brouwer-Lyddane model was chosen for orbit prediction because it meets the needs of HRPT tracking accuracies, provided orbital elements can be obtained frequently (up to within 1 week). Sea Track requires elements from the U.S. Space Command (NORAD Two-Line Elements) for the satellite's initial position. Updated Two-Line Elements are routinely available from many electronic sources (some are listed in the Appendix). Sea Track is a menu-driven program that allows users to alter input and output formats. The propagation period is entered by a start date and end date with times in either Greenwich Mean Time (GMT) or local time. Antenna pointing information is provided in tabular form and includes azimuth/elevation pointing angles, sub-satellite longitude/latitude, acquisition of signal (AOS), loss of signal (LOS), pass orbit number, and other pertinent pointing information. One version of Sea Track (non-graphical) allows operation under DOS (for IBM-compatible personal computers) and UNIX (for Sun and Silicon Graphics workstations). A second, graphical, version displays orbit tracks, and azimuth-elevation for IBM-compatible PC's, but requires a VGA card and Microsoft FORTRAN.

  15. Invited Article: First Flight in Space of a Wide-field-of-view Soft X-Ray Imager Using Lobster-Eye Optics: Instrument Description and Initial Flight Results

    Science.gov (United States)

    Collier, Michael; Porter, F. Scott; Sibeck, David G.; Carter, Jenny A.; Chiao, Meng P.; Chomay, Dennis J.; Cravens, Thomas E.; Galeazzi, Massiniliano; Keller, John; Koutroumpa, Dimitra

    2015-01-01

    We describe the development, launch into space, and initial results from a prototype wide eld-of-view (FOV) soft X-ray imager that employs Lobster-eye optics and targets heliophysics, planetary, and astrophysics science. The Sheath Transport Observer for the Redistribution of Mass (STORM) is the rst instrument using this type of optics launched into space and provides proof-of-concept for future ight instruments capable of imaging structures such as the terrestrial cusp, the entire dayside magnetosheath from outside the magnetosphere, comets, the moon, and the solar wind interaction with planetary bodies like Venus and Mars.

  16. A technique for automatically extracting useful field of view and central field of view images.

    Science.gov (United States)

    Pandey, Anil Kumar; Sharma, Param Dev; Aheer, Deepak; Kumar, Jay Prakash; Sharma, Sanjay Kumar; Patel, Chetan; Kumar, Rakesh; Bal, Chandra Sekhar

    2016-01-01

    It is essential to ensure the uniform response of the single photon emission computed tomography gamma camera system before using it for the clinical studies by exposing it to uniform flood source. Vendor specific acquisition and processing protocol provide for studying flood source images along with the quantitative uniformity parameters such as integral and differential uniformity. However, a significant difficulty is that the time required to acquire a flood source image varies from 10 to 35 min depending both on the activity of Cobalt-57 flood source and the pre specified counts in the vendors protocol (usually 4000K-10,000K counts). In case the acquired total counts are less than the total prespecified counts, and then the vendor's uniformity processing protocol does not precede with the computation of the quantitative uniformity parameters. In this study, we have developed and verified a technique for reading the flood source image, remove unwanted information, and automatically extract and save the useful field of view and central field of view images for the calculation of the uniformity parameters. This was implemented using MATLAB R2013b running on Ubuntu Operating system and was verified by subjecting it to the simulated and real flood sources images. The accuracy of the technique was found to be encouraging, especially in view of practical difficulties with vendor-specific protocols. It may be used as a preprocessing step while calculating uniformity parameters of the gamma camera in lesser time with fewer constraints.

  17. A technique for automatically extracting useful field of view and central field of view images

    International Nuclear Information System (INIS)

    Pandey, Anil Kumar; Sharma, Param Dev; Aheer, Deepak; Kumar, Jay Prakash; Sharma, Sanjay Kumar; Patel, Chetan; Kumar, Rakesh; Bal, Chandra Sekhar

    2016-01-01

    It is essential to ensure the uniform response of the single photon emission computed tomography gamma camera system before using it for the clinical studies by exposing it to uniform flood source. Vendor specific acquisition and processing protocol provide for studying flood source images along with the quantitative uniformity parameters such as integral and differential uniformity. However, a significant difficulty is that the time required to acquire a flood source image varies from 10 to 35 min depending both on the activity of Cobalt-57 flood source and the pre specified counts in the vendors protocol (usually 4000K-10,000K counts). In case the acquired total counts are less than the total prespecified counts, and then the vendor's uniformity processing protocol does not precede with the computation of the quantitative uniformity parameters. In this study, we have developed and verified a technique for reading the flood source image, remove unwanted information, and automatically extract and save the useful field of view and central field of view images for the calculation of the uniformity parameters. This was implemented using MATLAB R2013b running on Ubuntu Operating system and was verified by subjecting it to the simulated and real flood sources images. The accuracy of the technique was found to be encouraging, especially in view of practical difficulties with vendor-specific protocols. It may be used as a preprocessing step while calculating uniformity parameters of the gamma camera in lesser time with fewer constraints

  18. Virtual navigation performance: the relationship to field of view and prior video gaming experience.

    Science.gov (United States)

    Richardson, Anthony E; Collaer, Marcia L

    2011-04-01

    Two experiments examined whether learning a virtual environment was influenced by field of view and how it related to prior video gaming experience. In the first experiment, participants (42 men, 39 women; M age = 19.5 yr., SD = 1.8) performed worse on a spatial orientation task displayed with a narrow field of view in comparison to medium and wide field-of-view displays. Counter to initial hypotheses, wide field-of-view displays did not improve performance over medium displays, and this was replicated in a second experiment (30 men, 30 women; M age = 20.4 yr., SD = 1.9) presenting a more complex learning environment. Self-reported video gaming experience correlated with several spatial tasks: virtual environment pointing and tests of Judgment of Line Angle and Position, mental rotation, and Useful Field of View (with correlations between .31 and .45). When prior video gaming experience was included as a covariate, sex differences in spatial tasks disappeared.

  19. Holographic elements and curved slit used to enlarge field of view in rocket detection system

    Science.gov (United States)

    Breton, Mélanie; Fortin, Jean; Lessard, Roger A.; Châteauneuf, Marc

    2006-09-01

    Rocket detection over a wide field of view is an important issue in the protection of light armored vehicle. Traditionally, the detection occurs in UV band, but recent studies have shown the existence of significant emission peaks in the visible and near infrared at rocket launch time. The use of the visible region is interesting in order to reduce the weight and cost of systems. Current methods to detect those specific peaks involve use of interferometric filters. However, they fail to combine wide angle with wavelength selectivity. A linear array of volume holographic elements combined with a curved exit slit is proposed for the development of a wide field of view sensor for the detection of solid propellant motor launch flash. The sensor is envisaged to trigger an active protection system. On the basis of geometric theory, a system has been designed. It consists of a collector, a linear array of holographic elements, a curved slit and a detector. The collector is an off-axis parabolic mirror. Holographic elements are recorded subdividing a hologram film in regions, each individually exposed with a different incidence angle. All regions have a common diffraction angle. The incident angle determines the instantaneous field of view of the elements. The volume hologram performs the function of separating and focusing the diffracted beam on an image plane to achieve wavelength filtering. Conical diffraction property is used to enlarge the field of view in elevation. A curved slit was designed to correspond to oblique incidence of the holographic linear array. It is situated at the image plane and filters the diffracted spectrum toward the sensor. The field of view of the design was calculated to be 34 degrees. This was validated by a prototype tested during a field trial. Results are presented and analyzed. The system succeeded in detecting the rocket launch flash at desired fields of view.

  20. Internal and external Field of View: computer games and cybersickness

    NARCIS (Netherlands)

    Vries, S.C. de; Bos, J.E.; Emmerik, M.L. van; Groen, E.L.

    2007-01-01

    In an experiment with a computer game environment, we studied the effect of Field-of-View (FOV) on cybersickness. In particular, we examined the effect of differences between the internal FOV (IFOV, the FOV which the graphics generator is using to render its images) and the external FOV (EFOV, the

  1. Effect of field-of-view on the Coriolis illusion

    NARCIS (Netherlands)

    Groen, E.L.; Muis, H.; Kooi, F.L.

    2008-01-01

    Tilting the head during rotation about an Earth-vertical axis produces cross-coupled stimulation of the semicircular canals. Without visual feedback on the actual self-motion, this leads to the so-called Coriolis illusion. We investigated the effect of the field-of-view (FOV) on the magnitude and

  2. Multiplexing and de-multiplexing with scattering media for large field of view and multispectral imaging

    Science.gov (United States)

    Sahoo, Sujit Kumar; Tang, Dongliang; Dang, Cuong

    2018-02-01

    Large field of view multispectral imaging through scattering medium is a fundamental quest in optics community. It has gained special attention from researchers in recent years for its wide range of potential applications. However, the main bottlenecks of the current imaging systems are the requirements on specific illumination, poor image quality and limited field of view. In this work, we demonstrated a single-shot high-resolution colour-imaging through scattering media using a monochromatic camera. This novel imaging technique is enabled by the spatial, spectral decorrelation property and the optical memory effect of the scattering media. Moreover the use of deconvolution image processing further annihilate above-mentioned drawbacks arise due iterative refocusing, scanning or phase retrieval procedures.

  3. Narrow Field of View Zenith Radiometer (NFOV) Handbook

    Energy Technology Data Exchange (ETDEWEB)

    Chiu, C; Marshak, A; Hodges, G; Barnard, JC; Schmelzer, J

    2008-11-01

    The two-channel narrow field-of-view radiometer (NFOV2) is a ground-based radiometer that looks straight up and measures radiance directly above the instrument at wavelengths of 673 and 870 nm. The field-of-view of the instrument is 1.2 degrees, and the sampling time resolution is one second. Measurements of the NFOV2 have been used to retrieve optical properties for overhead clouds that range from patchy to overcast. With a one-second sampling rate of the NFOV2, faster than almost any other ARM Climate Research Facility (ACRF) instrument, we are able, for the first time, to capture changes in cloud optical properties at the natural time scale of cloud evolution.

  4. Dynamics of cell and tissue growth acquired by means of extended field of view lensfree microscopy.

    Science.gov (United States)

    Momey, F; Coutard, J-G; Bordy, T; Navarro, F; Menneteau, M; Dinten, J-M; Allier, C

    2016-02-01

    In this paper, we discuss a new methodology based on lensfree imaging to perform wound healing assay with unprecedented statistics. Our video lensfree microscopy setup is a simple device featuring only a CMOS sensor and a semi coherent illumination system. Yet it is a powerful mean for the real-time monitoring of cultivated cells. It presents several key advantages, e.g. integration into standard incubator, compatibility with standard cell culture protocol, simplicity and ease of use. It can perform the follow-up in a large field of view (25 mm(2)) of several crucial parameters during the culture of cells i.e. their motility, their proliferation rate or their death. Consequently the setup can gather large statistics both in space and time. Here we uses this facility in the context of wound healing assay to perform label-free measurements of the velocities of the fronts of proliferation of the cell layer as a function of time by means of particle image velocimetry (PIV) processing. However, for such tissue growth experiments, the field of view of 25 mm(2) remains not sufficient and results can be biased depending on the position of the device with respect to the recipient of the cell culture. Hence, to conduct exhaustive wound healing assays, we propose to enlarge the field of view up to 10 cm(2) through a raster scan, by moving the source/sensor with respect to the Petri dish. We have performed acquisitions of wound healing assay (keratinocytes HaCaT) both in real-time (25 mm(2)) and in final point (10 cm(2)) to assess the combination of velocimetry measurements and final point wide field imaging. In the future, we aim at combining directly our extended field of view acquisitions (>10 cm(2)) with real time ability inside the incubator.

  5. Photometric Calibration and Image Stitching for a Large Field of View Multi-Camera System

    Directory of Open Access Journals (Sweden)

    Yu Lu

    2016-04-01

    Full Text Available A new compact large field of view (FOV multi-camera system is introduced. The camera is based on seven tiny complementary metal-oxide-semiconductor sensor modules covering over 160° × 160° FOV. Although image stitching has been studied extensively, sensor and lens differences have not been considered in previous multi-camera devices. In this study, we have calibrated the photometric characteristics of the multi-camera device. Lenses were not mounted on the sensor in the process of radiometric response calibration to eliminate the influence of the focusing effect of uniform light from an integrating sphere. Linearity range of the radiometric response, non-linearity response characteristics, sensitivity, and dark current of the camera response function are presented. The R, G, and B channels have different responses for the same illuminance. Vignetting artifact patterns have been tested. The actual luminance of the object is retrieved by sensor calibration results, and is used to blend images to make panoramas reflect the objective luminance more objectively. This compensates for the limitation of stitching images that are more realistic only through the smoothing method. The dynamic range limitation of can be resolved by using multiple cameras that cover a large field of view instead of a single image sensor with a wide-angle lens. The dynamic range is expanded by 48-fold in this system. We can obtain seven images in one shot with this multi-camera system, at 13 frames per second.

  6. Design of UHECR telescope with 1 arcmin resolution and 50 deg. field of view

    CERN Document Server

    Sasaki, M; Asaoka, Y

    2002-01-01

    A new telescope design based on Baker-Nunn optics is proposed for observation of ultra-high-energy cosmic rays (UHECRs). The optical system has an image resolution better than 0.02 deg. within a wide field of view of 50 deg. angular diameter. When combined with a high-quality imaging device, the proposed design enables the directions of UHECRs and high-energy neutrinos to be determined with an accuracy better than 1 arcmin. The outstanding resolution of this telescope allows charge-separated cosmic-rays to be resolved and the source to be determined accurately. This marked improvement in angular resolution will allow the multi-wavelength and 'multi-particle' observations of astronomical objects through collaboration with established astronomical observations.

  7. Defining Constellation Suit Helmet Field of View Requirements Employing a Mission Segment Based Reduction Process

    Science.gov (United States)

    McFarland, Shane

    2009-01-01

    Field of view has always been a design feature paramount to helmets, and in particular space suits, where the helmet must provide an adequate field of view for a large range of activities, environments, and body positions. For Project Constellation, a different approach to helmet requirement maturation was utilized; one that was less a direct function of body position and suit pressure and more a function of the mission segment in which the field of view will be required. Through taxonimization of various parameters that affect suited field of view, as well as consideration for possible nominal and contingency operations during that mission segment, a reduction process was employed to condense the large number of possible outcomes to only six unique field of view angle requirements that still captured all necessary variables while sacrificing minimal fidelity.

  8. Accurate and wide field of view MEMS-based sun sensor for industrial applications

    OpenAIRE

    Delgado, Francisco; Quero, J.M.; Garcia Ortega, Juan; López Tarrida, Cristina; Ortega Villasclaras, Pablo Rafael; Bermejo Broto, Sandra

    2012-01-01

    This paper describes the design, fabrication, sim- ulation, and experimental results of an improved miniaturized two-axis sun sensor for industrial applications, created by adapt- ing a technology used previously in satellite applications. The sensor for each axis is composed of six photodiodes integrated in a crystalline-silicon substrate and a layer of cover glass, which is used to protect the silicon and to hold the windows. The high preci...

  9. Retina-like sensor based on a lens array with a large field of view.

    Science.gov (United States)

    Fan, Fan; Hao, Qun; Cheng, Xuemin

    2015-12-20

    This paper puts forward a retina-like sensor based on a lens array, which can be used in conventional optical systems. This sensor achieves log-polar mapping by dividing the imaging optical system's image plane using a lens array. In this paper the mathematical model has been set up with the relative structural parameters. Also, the simulation experiments and parameter analysis have been discussed to verify the reliability of this system. From the experiment results, it can be seen that this sensor realized the log-polar mapping with the transformed image output. Each lens corresponded to a circular region in the image plane with no crossover between different fields of view of adjacent lenses. When the number of rings changed, the relative error did not significantly change, and this error could be reduced to 1% when the number of lenses in each ring was increased. The work widely enlarged the application of this kind of sensor, which will lay a theoretical foundation for retina-like sensors.

  10. The CCAT-prime Extreme Field-of-View Submillimeter Telescope on Cerro Chajnantor

    Science.gov (United States)

    Koopman, Brian; Bertoldi, Frank; Chapman, Scott; Fich, Michel; Giovanelli, Riccardo; Haynes, Martha P.; Herter, Terry L.; Murray, Norman W.; Niemack, Michael D.; Riechers, Dominik; Schilke, Peter; Stacey, Gordon J.; Stutzki, Juergen; CCAT-prime Collaboration

    2017-01-01

    CCAT-prime is a six meter aperture off-axis submillimeter telescope that we plan to build at 5600m elevation on Cerro Chajnantor in Chile. The CCAT-prime optics are based on a cross-Dragone design with high throughput and a wide field-of-view optimized to increase the mapping speed of next generation cosmic microwave background (CMB) observations. These characteristics make CCAT-prime an excellent platform for a wide range of next generation millimeter and submillimeter science goals, and a potential platform for CMB stage-IV measurements. Here we present the telescope design for CCAT-prime and review the science goals.Taking advantage of the high elevation site, the first generation instrument for CCAT-prime will measure seven different frequency bands from 350um to 3mm. These seven bands will enable precise measurements of the Sunyaev-Zel’dovich effects (SZE) by separating contributions from CMB, thermal SZE, kinetic SZE, bright submm galaxies, and radio sources with a goal of extracting the peculiar velocities from a large number of galaxy clusters. Additional science priorities for CCAT-prime include: Galactic Ecology studies of the dynamic intersteller medium by mapping the fine structure lines [CI], [CII] and [NII] as well as high-excitation CO lines at the shortest wavelength bands; high redshift intensity mapping of [CII] emission from star-forming galaxies that likely dominates cosmic reionization at z~5-9 to probe the Epoch of Reionization; and next generation CMB polarization measurements to constrain inflation and cosmological models. The CCAT-prime facility will further our understanding of astrophysical processes from moments after the Big Bang to the present-day evolution of the Milky Way.

  11. Real-time RGB-D image stitching using multiple Kinects for improved field of view

    Directory of Open Access Journals (Sweden)

    Hengyu Li

    2017-03-01

    Full Text Available This article concerns the problems of a defective depth map and limited field of view of Kinect-style RGB-D sensors. An anisotropic diffusion based hole-filling method is proposed to recover invalid depth data in the depth map. The field of view of the Kinect-style RGB-D sensor is extended by stitching depth and color images from several RGB-D sensors. By aligning the depth map with the color image, the registration data calculated by registering color images can be used to stitch depth and color images into a depth and color panoramic image concurrently in real time. Experiments show that the proposed stitching method can generate a RGB-D panorama with no invalid depth data and little distortion in real time and can be extended to incorporate more RGB-D sensors to construct even a 360° field of view panoramic RGB-D image.

  12. Older Adult Multitasking Performance Using a Gaze-Contingent Useful Field of View.

    Science.gov (United States)

    Ward, Nathan; Gaspar, John G; Neider, Mark B; Crowell, James; Carbonari, Ronald; Kaczmarski, Hank; Ringer, Ryan V; Johnson, Aaron P; Loschky, Lester C; Kramer, Arthur F

    2018-03-01

    Objective We implemented a gaze-contingent useful field of view paradigm to examine older adult multitasking performance in a simulated driving environment. Background Multitasking refers to the ability to manage multiple simultaneous streams of information. Recent work suggests that multitasking declines with age, yet the mechanisms supporting these declines are still debated. One possible framework to better understand this phenomenon is the useful field of view, or the area in the visual field where information can be attended and processed. In particular, the useful field of view allows for the discrimination of two competing theories of real-time multitasking, a general interference account and a tunneling account. Methods Twenty-five older adult subjects completed a useful field of view task that involved discriminating the orientation of lines in gaze-contingent Gabor patches appearing at varying eccentricities (based on distance from the fovea) as they operated a vehicle in a driving simulator. In half of the driving scenarios, subjects also completed an auditory two-back task to manipulate cognitive workload, and during some trials, wind was introduced as a means to alter general driving difficulty. Results Consistent with prior work, indices of driving performance were sensitive to both wind and workload. Interestingly, we also observed a decline in Gabor patch discrimination accuracy under high cognitive workload regardless of eccentricity, which provides support for a general interference account of multitasking. Conclusion The results showed that our gaze-contingent useful field of view paradigm was able to successfully examine older adult multitasking performance in a simulated driving environment. Application This study represents the first attempt to successfully measure dynamic changes in the useful field of view for older adults completing a multitasking scenario involving driving.

  13. Optical design of an athermalised dual field of view step zoom optical system in MWIR

    Science.gov (United States)

    Kucukcelebi, Doruk

    2017-08-01

    In this paper, the optical design of an athermalised dual field of view step zoom optical system in MWIR (3.7μm - 4.8μm) is described. The dual field of view infrared optical system is designed based on the principle of passive athermalization method not only to achieve athermal optical system but also to keep the high image quality within the working temperature between -40°C and +60°C. The infrared optical system used in this study had a 320 pixel x 256 pixel resolution, 20μm pixel pitch size cooled MWIR focal plane array detector. In this study, the step zoom mechanism, which has the axial motion due to consisting of a lens group, is considered to simplify mechanical structure. The optical design was based on moving a single lens along the optical axis for changing the optical system's field of view not only to reduce the number of moving parts but also to athermalize for the optical system. The optical design began with an optimization process using paraxial optics when first-order optics parameters are determined. During the optimization process, in order to reduce aberrations, such as coma, astigmatism, spherical and chromatic aberrations, aspherical surfaces were used. As a result, athermalised dual field of view step zoom optical design is proposed and the performance of the design using proposed method was verified by providing the focus shifts, spot diagrams and MTF analyzes' plots.

  14. Hemispherical-field-of-view, nonimaging narrow-band spectral filter

    Science.gov (United States)

    Miles, R. B.; Webb, S. G.; Griffith, E. L.

    1981-01-01

    Two compound parabolic concentrators are used to create a 180-deg-field-of-view spectral filter. The collection optics are reflective and are designed to collimate the light through a multilayer interference filter and then to refocus it onto an optical detector. Assuming unit reflectance and no loss through the optical filter, this device operates at the thermodynamic collection limit.

  15. The effect of internal and external fields of view on visually induced motion sickness

    NARCIS (Netherlands)

    Bos, J.E.; Vries, S.C. de; Emmerik, M.L. van; Groen, E.L.

    2010-01-01

    Field of view (FOV) is said to affect visually induced motion sickness. FOV, however, is characterized by an internal setting used by the graphics generator (iFOV) and an external factor determined by screen size and viewing distance (eFOV). We hypothesized that especially the incongruence between

  16. Restricting the vertical and horizontal extent of the Field-of-View: Effects on manoeuvring performance

    NARCIS (Netherlands)

    Jansen, S.E.M.; Toet, A.; Delleman, N.J.

    2010-01-01

    It is known that Field-of-view restrictions affect distance estimation, postural equilibrium, and the ability to control heading. These are all important factors when manoeuvring on foot through complex structured environments. Although considerable research has been devoted to the horizontal

  17. Performance Modelling of Automatic Identification System with Extended Field of View

    DEFF Research Database (Denmark)

    Lauersen, Troels; Mortensen, Hans Peter; Pedersen, Nikolaj Bisgaard

    2010-01-01

    This paper deals with AIS (Automatic Identification System) behavior, to investigate the severity of packet collisions in an extended field of view (FOV). This is an important issue for satellite-based AIS, and the main goal is a feasibility study to find out to what extent an increased FOV...

  18. Development of a volumetric projection technique for the digital evaluation of field of view.

    Science.gov (United States)

    Marshall, Russell; Summerskill, Stephen; Cook, Sharon

    2013-01-01

    Current regulations for field of view requirements in road vehicles are defined by 2D areas projected on the ground plane. This paper discusses the development of a new software-based volumetric field of view projection tool and its implementation within an existing digital human modelling system. In addition, the exploitation of this new tool is highlighted through its use in a UK Department for Transport funded research project exploring the current concerns with driver vision. Focusing specifically on rearwards visibility in small and medium passenger vehicles, the volumetric approach is shown to provide a number of distinct advantages. The ability to explore multiple projections of both direct vision (through windows) and indirect vision (through mirrors) provides a greater understanding of the field of view environment afforded to the driver whilst still maintaining compatibility with the 2D projections of the regulatory standards. Field of view requirements for drivers of road vehicles are defined by simplified 2D areas projected onto the ground plane. However, driver vision is a complex 3D problem. This paper presents the development of a new software-based 3D volumetric projection technique and its implementation in the evaluation of driver vision in small- and medium-sized passenger vehicles.

  19. Optimization of a novel large field of view distortion phantom for MR-only treatment planning.

    Science.gov (United States)

    Price, Ryan G; Knight, Robert A; Hwang, Ken-Pin; Bayram, Ersin; Nejad-Davarani, Siamak P; Glide-Hurst, Carri K

    2017-07-01

    MR-only treatment planning requires images of high geometric fidelity, particularly for large fields of view (FOV). However, the availability of large FOV distortion phantoms with analysis software is currently limited. This work sought to optimize a modular distortion phantom to accommodate multiple bore configurations and implement distortion characterization in a widely implementable solution. To determine candidate materials, 1.0 T MR and CT images were acquired of twelve urethane foam samples of various densities and strengths. Samples were precision-machined to accommodate 6 mm diameter paintballs used as landmarks. Final material candidates were selected by balancing strength, machinability, weight, and cost. Bore sizes and minimum aperture width resulting from couch position were tabulated from the literature (14 systems, 5 vendors). Bore geometry and couch position were simulated using MATLAB to generate machine-specific models to optimize the phantom build. Previously developed software for distortion characterization was modified for several magnet geometries (1.0 T, 1.5 T, 3.0 T), compared against previously published 1.0 T results, and integrated into the 3D Slicer application platform. All foam samples provided sufficient MR image contrast with paintball landmarks. Urethane foam (compressive strength ∼1000 psi, density ~20 lb/ft 3 ) was selected for its accurate machinability and weight characteristics. For smaller bores, a phantom version with the following parameters was used: 15 foam plates, 55 × 55 × 37.5 cm 3 (L×W×H), 5,082 landmarks, and weight ~30 kg. To accommodate > 70 cm wide bores, an extended build used 20 plates spanning 55 × 55 × 50 cm 3 with 7,497 landmarks and weight ~44 kg. Distortion characterization software was implemented as an external module into 3D Slicer's plugin framework and results agreed with the literature. The design and implementation of a modular, extendable distortion phantom was optimized for several bore

  20. Retrieval of Droplet size Density Distribution from Multiple field of view Cross polarized Lidar Signals: Theory and Experimental Validation

    Science.gov (United States)

    2016-06-02

    Retrieval of droplet-size density distribution from multiple-field-of-view cross-polarized lidar signals: theory and experimental validation...Gilles Roy, Luc Bissonnette, Christian Bastille, and Gilles Vallee Multiple-field-of-view (MFOV) secondary-polarization lidar signals are used to...use secondary polarization. A mathematical relation among the PSD, the lidar fields of view, the scattering angles, and the angular depolarization

  1. Optimal usage of cone beam computed tomography system with different field of views in image guided radiotherapy (IGRT

    Directory of Open Access Journals (Sweden)

    Narayana Venkata Naga Madhusudhana Sresty

    2015-09-01

    Full Text Available Purpose: To find methods for optimal usage of XVI (X-ray volume imaging system in Elekta synergy linear accelerator with different field of views for same lesion in order to minimize patient dose due to imaging.Methods: 20 scans of 2 individual patients with ca sigmoid colon and ca lung were used in this study. Kilo voltage collimators with medium field of view were used as per the preset information. Images were reconstructed for another collimator with small field of view. The set up errors were evaluated with XVI software. Shift results of both methods were compared. Results: Variation in treatment set up errors with M20 and S20 collimators were ≤ 0.2 mm in translational and 0.30 in rotational shifts. Results showed almost equal translational and rotational shifts in both medium and small field of views with different collimators in all the scans. Visualization of target and surrounding structures were good enough and sufficient for XVI auto matching.Conclusion: Imaging with small field of view results less patient dose compared with medium or large field of views. It is Suggestible to use collimators with small field of view wherever possible. In this study, collimators with small field of view were sufficient for both patients though the preset information indicated medium field of view. But, it always depends on the area required for matching purpose. So, individual selection is important than preset information in the XVI system.

  2. High speed color imaging through scattering media with a large field of view

    Science.gov (United States)

    Zhuang, Huichang; He, Hexiang; Xie, Xiangsheng; Zhou, Jianying

    2016-09-01

    Optical imaging through complex media has many important applications. Although research progresses have been made to recover optical image through various turbid media, the widespread application of the technology is hampered by the recovery speed, requirement on specific illumination, poor image quality and limited field of view. Here we demonstrate that above-mentioned drawbacks can be essentially overcome. The realization of high speed color imaging through turbid media is successfully carried out by taking into account the media memory effect, the point spread function, the exit pupil of the optical system, and the optimized signal to noise ratio. By retrieving selected speckles with enlarged field of view, high quality image is recovered with a responding speed only determined by the frame rates of the image capturing devices. The immediate application of the technique is expected to register static and dynamic imaging under human skin to recover information with a wearable device.

  3. Error Analysis and Calibration Method of a Multiple Field-of-View Navigation System

    OpenAIRE

    Shi, Shuai; Zhao, Kaichun; You, Zheng; Ouyang, Chenguang; Cao, Yongkui; Wang, Zhenzhou

    2017-01-01

    The Multiple Field-of-view Navigation System (MFNS) is a spacecraft subsystem built to realize the autonomous navigation of the Spacecraft Inside Tiangong Space Station. This paper introduces the basics of the MFNS, including its architecture, mathematical model and analysis, and numerical simulation of system errors. According to the performance requirement of the MFNS, the calibration of both intrinsic and extrinsic parameters of the system is assumed to be essential and pivotal. Hence, a n...

  4. A new method for determining which stars are near a star sensor field-of-view

    Science.gov (United States)

    Yates, Russell E., Jr.; Vedder, John D.

    1991-01-01

    A new method is described for determining which stars in a navigation star catalog are near a star sensor field of view (FOV). This method assumes that an estimate of spacecraft inertial attitude is known. Vector component ranges for the star sensor FOV are computed, so that stars whose vector components lie within these ranges are near the star sensor FOV. This method requires no presorting of the navigation star catalog, and is more efficient than tradition methods.

  5. Large-field-of-view imaging by multi-pupil adaptive optics.

    Science.gov (United States)

    Park, Jung-Hoon; Kong, Lingjie; Zhou, Yifeng; Cui, Meng

    2017-06-01

    Adaptive optics can correct for optical aberrations. We developed multi-pupil adaptive optics (MPAO), which enables simultaneous wavefront correction over a field of view of 450 × 450 μm 2 and expands the correction area to nine times that of conventional methods. MPAO's ability to perform spatially independent wavefront control further enables 3D nonplanar imaging. We applied MPAO to in vivo structural and functional imaging in the mouse brain.

  6. Large field-of-view transmission line resonator for high field MRI

    DEFF Research Database (Denmark)

    Zhurbenko, Vitaliy; Johannesson, Kristjan Sundgaard; Boer, Vincent

    2016-01-01

    Transmission line resonators is often a preferable choice for coils in high field magnetic resonance imaging (MRI), because they provide a number of advantages over traditional loop coils. The size of such resonators, however, is limited to shorter than half a wavelength due to high standing wave....... Achieved magnetic field distribution is compared to the conventional transmission line resonator. Imaging experiments are performed using 7 Tesla MRI system. The developed resonator is useful for building coils with large field-of-view....

  7. Field of view of limitations in see-through HMD using geometric waveguides.

    Science.gov (United States)

    DeHoog, Edward; Holmstedt, Jason; Aye, Tin

    2016-08-01

    Geometric waveguides are being integrated into head-mounted display (HMD) systems, where having see-through capability in a compact, lightweight form factor is required. We developed methods for determining the field of view (FOV) of such waveguide HMD systems and have analytically derived the FOV for waveguides using planar and curved geometries. By using real ray-tracing methods, we are able to show how the geometry and index of refraction of the waveguide, as well as the properties of the coupling optics, impact the FOV. Use of this analysis allows one to determine the maximum theoretical FOV of a planar or curved waveguide-based system.

  8. Time-Varying Biased Proportional Guidance with Seeker’s Field-of-View Limit

    OpenAIRE

    Yang, Zhe; Wang, Hui; Lin, Defu

    2016-01-01

    Traditional guidance laws with range-to-go information or time-to-go estimation may not be implemented in passive homing missiles since passive seekers cannot measure relative range directly. A time-varying biased proportional guidance law, which only uses line-of-sight (LOS) rate and look angle information, is proposed to satisfy both impact angle constraint and seeker’s field-of-view (FOV) limit. In the proposed guidance law, two time-varying bias terms are applied to divide the trajectory ...

  9. One-inch field of view imaging probe for breast cancer sentinel node location

    International Nuclear Information System (INIS)

    D'Errico, Giovanni; Scafe, Raffaele; Soluri, Alessandro; Schiaratura, Alfiero; Maria Mangano, Anna; David, Vincenzo; Scopinaro, Francesco

    2003-01-01

    The already reported 1-in. 2 field of view mini gamma camera known since 1998 with the name of Imaging Probe (IP), has been used for sentinel node localization by a medical equipe that, though trained by the group of nuclear physicians of the University 'La Sapienza' who first conceived and used this detector, has used IP in its own Hospital to: (1) gain experience for future use during operations--a cooperative work on IP radio guided orthopaedic operations has already started working, and (2) to start with IP multicenter trials. In six patients with breast cancer, who underwent lymphoscintigraphy for sentinel node biopsy, sentinel node was checked and located with IP and non-imaging Neoprobe 2000 CdTe (Zn) probe, independent of location by means of large field of view Anger camera. Operators who used Neoprobe and IP were blinded to each other and not aware of the results of Anger camera imaging. Anger camera, as well as IP and neoprobe detected 7 nodes in 6 pts. Detection time was 2', 06'' SD 26'' with IP and 2', 18'' SD 47'' with neoprobe 2000. The most difficult to find node required 2 min and 56 s--inside sd--for IP detection and 3 min and 45 s with neoprobe. Subjective impression of being sure of having detected sentinel node was: absolutely sure on 7/7 nodes with IP and on 5/7 nodes with neoprobe

  10. Studies of the field-of-view resolution tradeoff in virtual-reality systems

    Science.gov (United States)

    Piantanida, Thomas P.; Boman, Duane; Larimer, James; Gille, Jennifer; Reed, Charles

    1992-01-01

    Most virtual-reality systems use LCD-based displays that achieve a large field-of-view at the expense of resolution. A typical display will consist of approximately 86,000 pixels uniformly distributed over an 80-degree by 60-degree image. Thus, each pixel subtends about 13 minutes of arc at the retina; about the same as the resolvable features of the 20/200 line of a Snellen Eye Chart. The low resolution of LCD-based systems limits task performance in some applications. We have examined target-detection performance in a low-resolution virtual world. Our synthesized three-dimensional virtual worlds consisted of target objects that could be positioned at a fixed distance from the viewer, but at random azimuth and constrained elevation. A virtual world could be bounded by chromatic walls or by wire-frame, or it could be unbounded. Viewers scanned these worlds and indicated by appropriate gestures when they had detected the target object. By manipulating the viewer's field size and the chromatic and luminance contrast of annuli surrounding the field-of-view, we were able to assess the effect of field size on the detection of virtual objects in low-resolution synthetic worlds.

  11. Face inversion and acquired prosopagnosia reduce the size of the perceptual field of view.

    Science.gov (United States)

    Van Belle, Goedele; Lefèvre, Philippe; Rossion, Bruno

    2015-03-01

    Using a gaze-contingent morphing approach, we asked human observers to choose one of two faces that best matched the identity of a target face: one face corresponded to the reference face's fixated part only (e.g., one eye), the other corresponded to the unfixated area of the reference face. The face corresponding to the fixated part was selected significantly more frequently in the inverted than in the upright orientation. This observation provides evidence that face inversion reduces an observer's perceptual field of view, even when both upright and inverted faces are displayed at full view and there is no performance difference between these conditions. It rules out an account of the drop of performance for inverted faces--one of the most robust effects in experimental psychology--in terms of a mere difference in local processing efficiency. A brain-damaged patient with pure prosopagnosia, viewing only upright faces, systematically selected the face corresponding to the fixated part, as if her perceptual field was reduced relative to normal observers. Altogether, these observations indicate that the absence of visual knowledge reduces the perceptual field of view, supporting an indirect view of visual perception. Copyright © 2014 Elsevier B.V. All rights reserved.

  12. Resonant Scanning with Large Field of View Reduces Photobleaching and Enhances Fluorescence Yield in STED Microscopy.

    Science.gov (United States)

    Wu, Yong; Wu, Xundong; Lu, Rong; Zhang, Jin; Toro, Ligia; Stefani, Enrico

    2015-10-01

    Photobleaching is a major limitation of superresolution Stimulated Depletion Emission (STED) microscopy. Fast scanning has long been considered an effective means to reduce photobleaching in fluorescence microscopy, but a careful quantitative study of this issue is missing. In this paper, we show that the photobleaching rate in STED microscopy can be slowed down and the fluorescence yield be enhanced by scanning with high speed, enabled by using large field of view in a custom-built resonant-scanning STED microscope. The effect of scanning speed on photobleaching and fluorescence yield is more remarkable at higher levels of depletion laser irradiance, and virtually disappears in conventional confocal microscopy. With ≥6 GW∙cm(-2) depletion irradiance, we were able to extend the fluorophore survival time of Atto 647N and Abberior STAR 635P by ~80% with 8-fold wider field of view. We confirm that STED Photobleaching is primarily caused by the depletion light acting upon the excited fluorophores. Experimental data agree with a theoretical model. Our results encourage further increasing the linear scanning speed for photobleaching reduction in STED microscopy.

  13. Visual search for features and conjunctions following declines in the useful field of view.

    Science.gov (United States)

    Cosman, Joshua D; Lees, Monica N; Lee, John D; Rizzo, Matthew; Vecera, Shaun P

    2012-01-01

    BACKGROUND/STUDY CONTEXT: Typical measures for assessing the useful field (UFOV) of view involve many components of attention. The objective of the current experiment was to examine differences in visual search efficiency for older individuals with and without UFOV impairment. The authors used a computerized screening instrument to assess the useful field of view and to characterize participants as having an impaired or normal UFOV. Participants also performed two visual search tasks, a feature search (e.g., search for a green target among red distractors) or a conjunction search (e.g., a green target with a gap on its left or right side among red distractors with gaps on the left or right and green distractors with gaps on the top or bottom). Visual search performance did not differ between UFOV impaired and unimpaired individuals when searching for a basic feature. However, search efficiency was lower for impaired individuals than unimpaired individuals when searching for a conjunction of features. The results suggest that UFOV decline in normal aging is associated with conjunction search. This finding suggests that the underlying cause of UFOV decline may arise from an overall decline in attentional efficiency. Because the useful field of view is a reliable predictor of driving safety, the results suggest that decline in the everyday visual behavior of older adults might arise from attentional declines.

  14. High-resolution small field-of-view magnetic resonance image acquisition system using a small planar coil and a pneumatic manipulator in an open MRI scanner.

    Science.gov (United States)

    Miki, Kohei; Masamune, Ken

    2015-10-01

    Low-field open magnetic resonance imaging (MRI) is frequently used for performing image-guided neurosurgical procedures. Intraoperative magnetic resonance (MR) images are useful for tracking brain shifts and verifying residual tumors. However, it is difficult to precisely determine the boundary of the brain tumors and normal brain tissues because the MR image resolution is low, especially when using a low-field open MRI scanner. To overcome this problem, a high-resolution MR image acquisition system was developed and tested. An MR-compatible manipulator with pneumatic actuators containing an MR signal receiver with a small radiofrequency (RF) coil was developed. The manipulator had five degrees of freedom for position and orientation control of the RF coil. An 8-mm planar RF coil with resistance and inductance of 2.04 [Formula: see text] and 1.00 [Formula: see text] was attached to the MR signal receiver at the distal end of the probe. MR images of phantom test devices were acquired using the MR signal receiver and normal head coil for signal-to-noise ratio (SNR) testing. The SNR of MR images acquired using the MR signal receiver was 8.0 times greater than that of MR images acquired using the normal head coil. The RF coil was moved by the manipulator, and local MR images of a phantom with a 2-mm grid were acquired using the MR signal receiver. A wide field-of-view MR image was generated from a montage of local MR images. A small field-of-view RF system with a pneumatic manipulator was integrated in a low-field MRI scanner to allow acquisition of both wide field-of-view and high-resolution MR images. This system is promising for image-guided neurosurgery as it may allow brain tumors to be observed more clearly and removed precisely.

  15. Experimental study of the field-of-view of neutron detectors towards thermohydraulic perturbances

    International Nuclear Information System (INIS)

    Kozma, R.

    1988-05-01

    The aim of the present study was to identify different stages of boiling during the HOR experiments at the 2 MW reactor of IRI (Interfaculty Reactor Inst.), Delft, Netherlands. The electrical heating power was increased while the flow rate was constant, thus inducing a single-phase flow, and afterwards subcooled boiling and finally developed volume boiling of the coolant in the experimental assembly. Subcooled boiling and the onset of boiling could not be detected using neutron detectors. This behaviour shows that the field of view of the NDs is very limited. The neutron noise signals remained unchanged, though at a distance of 3-10 cm developed volume boiling arose. Only the steam-packets in the slug-type flow during measurement III caused changes in the neutro noise. (author) 12 refs.; 20 figs

  16. In vivo assessment of muscle fascicle length by extended field-of-view ultrasonography

    DEFF Research Database (Denmark)

    Noorkoiv, M; Stavnsbo, A; Aagaard, Per

    2010-01-01

    The present study examined the reliability and validity of in vivo vastus lateralis (VL) fascicle length (L(f)) assessment by extended field-of-view ultrasonography (EFOV US). Intraexperimenter and intersession reliability of EFOV US were tested. Further, L(f) measured from EFOV US images were...... compared to L(f) measured from static US images (6-cm FOV) where out-of-field fascicle portions were trigonometrically estimated (linear extrapolation). Finally, spatial accuracy of the EFOV technique was assessed by comparing L(f) measured on swine VL by EFOV US to actual measurements from digital...... and by dissective assessment (digital photographs) in isolated swine VL was 0.84% ± 2.6% with an ICC of 0.99 (CI = 0.94-1.00). These results show that EFOV US is a reliable and valid method for the measurement of long muscle fascicle in vivo. Thus EFOV US analysis was proven more accurate for the assessment...

  17. Plasmonic micropillars for precision cell force measurement across a large field-of-view

    Science.gov (United States)

    Xiao, Fan; Wen, Ximiao; Tan, Xing Haw Marvin; Chiou, Pei-Yu

    2018-01-01

    A plasmonic micropillar platform with self-organized gold nanospheres is reported for the precision cell traction force measurement across a large field-of-view (FOV). Gold nanospheres were implanted into the tips of polymer micropillars by annealing gold microdisks with nanosecond laser pulses. Each gold nanosphere is physically anchored in the center of a pillar tip and serves as a strong, point-source-like light scattering center for each micropillar. This allows a micropillar to be clearly observed and precisely tracked even under a low magnification objective lens for the concurrent and precision measurement across a large FOV. A spatial resolution of 30 nm for the pillar deflection measurement has been accomplished on this platform with a 20× objective lens.

  18. The effect of internal and external fields of view on visually induced motion sickness.

    Science.gov (United States)

    Bos, Jelte E; de Vries, Sjoerd C; van Emmerik, Martijn L; Groen, Eric L

    2010-07-01

    Field of view (FOV) is said to affect visually induced motion sickness. FOV, however, is characterized by an internal setting used by the graphics generator (iFOV) and an external factor determined by screen size and viewing distance (eFOV). We hypothesized that especially the incongruence between iFOV and eFOV would lead to sickness. To that end we used a computer game environment with different iFOV and eFOV settings, and found the opposite effect. We speculate that the relative large differences between iFOV and eFOV used in this experiment caused the discrepancy, as may be explained by assuming an observer model controlling body motion. Copyright 2009 Elsevier Ltd. All rights reserved.

  19. Imaging samples larger than the field of view: the SLS experience

    Science.gov (United States)

    Vogiatzis Oikonomidis, Ioannis; Lovric, Goran; Cremona, Tiziana P.; Arcadu, Filippo; Patera, Alessandra; Schittny, Johannes C.; Stampanoni, Marco

    2017-06-01

    Volumetric datasets with micrometer spatial and sub-second temporal resolutions are nowadays routinely acquired using synchrotron X-ray tomographic microscopy (SRXTM). Although SRXTM technology allows the examination of multiple samples with short scan times, many specimens are larger than the field-of-view (FOV) provided by the detector. The extension of the FOV in the direction perpendicular to the rotation axis remains non-trivial. We present a method that can efficiently increase the FOV merging volumetric datasets obtained by region-of-interest tomographies in different 3D positions of the sample with a minimal amount of artefacts and with the ability to handle large amounts of data. The method has been successfully applied for the three-dimensional imaging of a small number of mouse lung acini of intact animals, where pixel sizes down to the micrometer range and short exposure times are required.

  20. Autonomous Rendezvous and Docking with Nonfull Field of View for Tethered Space Robot

    Directory of Open Access Journals (Sweden)

    Panfeng Huang

    2017-01-01

    Full Text Available In the ultra-close approaching phase of tethered space robot, a highly stable self-attitude control is essential. However, due to the field of view limitation of cameras, typical point features are difficult to extract, where commonly adopted position-based visual servoing cannot be valid anymore. To provide robot’s relative position and attitude with the target, we propose a monocular visual servoing control method using only the edge lines of satellite brackets. Firstly, real time detection of edge lines is achieved based on image gradient and region growing. Then, we build an edge line based model to estimate the relative position and attitude between the robot and the target. Finally, we design a visual servoing controller combined with PD controller. Experimental results demonstrate that our algorithm can extract edge lines stably and adjust the robot’s attitude to satisfy the grasping requirements.

  1. Homography-based control scheme for mobile robots with nonholonomic and field-of-view constraints.

    Science.gov (United States)

    López-Nicolás, Gonzalo; Gans, Nicholas R; Bhattacharya, Sourabh; Sagüés, Carlos; Guerrero, Josechu J; Hutchinson, Seth

    2010-08-01

    In this paper, we present a visual servo controller that effects optimal paths for a nonholonomic differential drive robot with field-of-view constraints imposed by the vision system. The control scheme relies on the computation of homographies between current and goal images, but unlike previous homography-based methods, it does not use the homography to compute estimates of pose parameters. Instead, the control laws are directly expressed in terms of individual entries in the homography matrix. In particular, we develop individual control laws for the three path classes that define the language of optimal paths: rotations, straight-line segments, and logarithmic spirals. These control laws, as well as the switching conditions that define how to sequence path segments, are defined in terms of the entries of homography matrices. The selection of the corresponding control law requires the homography decomposition before starting the navigation. We provide a controllability and stability analysis for our system and give experimental results.

  2. Impact Angle and Time Control Guidance Under Field-of-View Constraints and Maneuver Limits

    Science.gov (United States)

    Shim, Sang-Wook; Hong, Seong-Min; Moon, Gun-Hee; Tahk, Min-Jea

    2018-04-01

    This paper proposes a guidance law which considers the constraints of seeker field-of-view (FOV) as well as the requirements on impact angle and time. The proposed guidance law is designed for a constant speed missile against a stationary target. The guidance law consists of two terms of acceleration commands. The first one is to achieve zero-miss distance and the desired impact angle, while the second is to meet the desired impact time. To consider the limits of FOV and lateral maneuver capability, a varying-gain approach is applied on the second term. Reduction of realizable impact times due to these limits is then analyzed by finding the longest course among the feasible ones. The performance of the proposed guidance law is demonstrated by numerical simulation for various engagement conditions.

  3. Active control of acoustic field-of-view in a biosonar system.

    Directory of Open Access Journals (Sweden)

    Yossi Yovel

    2011-09-01

    Full Text Available Active-sensing systems abound in nature, but little is known about systematic strategies that are used by these systems to scan the environment. Here, we addressed this question by studying echolocating bats, animals that have the ability to point their biosonar beam to a confined region of space. We trained Egyptian fruit bats to land on a target, under conditions of varying levels of environmental complexity, and measured their echolocation and flight behavior. The bats modulated the intensity of their biosonar emissions, and the spatial region they sampled, in a task-dependant manner. We report here that Egyptian fruit bats selectively change the emission intensity and the angle between the beam axes of sequentially emitted clicks, according to the distance to the target, and depending on the level of environmental complexity. In so doing, they effectively adjusted the spatial sector sampled by a pair of clicks-the "field-of-view." We suggest that the exact point within the beam that is directed towards an object (e.g., the beam's peak, maximal slope, etc. is influenced by three competing task demands: detection, localization, and angular scanning-where the third factor is modulated by field-of-view. Our results suggest that lingual echolocation (based on tongue clicks is in fact much more sophisticated than previously believed. They also reveal a new parameter under active control in animal sonar-the angle between consecutive beams. Our findings suggest that acoustic scanning of space by mammals is highly flexible and modulated much more selectively than previously recognized.

  4. Effect of age and pop out distracter on attended field of view.

    Science.gov (United States)

    Babu, Raiju J; Leat, Susan J; Irving, Elizabeth L

    2014-01-01

    To investigate the functional field of view (FFOV) of younger and older individuals using the attended field of view (AFOV), a method which allows for eye and head movement. The impact of a pop out distracter and a dual task on the FFOV measure was also investigated. Nine young adult (25±6 years) and 9 older participants (72±4 years) took part in the experiment. The AFOV test involved the binocular detection and localization of a white target (Landolt-C) in a field of 24 white rings (distracters). The further AFOV tests were modified to include the presence of a pop out distracter, a dual task condition, and a combination of the two. Older observers had lower viewing efficiency (log [1/presentation time]) in all conditions (pooled mean across conditions: older: 0.05±0.02; younger: 0.48±0.04) than the younger group. The addition of dual or a pop out distracter did not affect the older group (mean difference ∼104±150ms and ∼124±122ms respectively) but the additional pop out distracter reduced the efficiency of the younger group for targets near fixation (mean difference ∼68±35ms). Better viewing efficiency was observed in younger individuals compared to older individuals. Difficulty in disregarding irrelevant stimuli and thereby resorting to inefficient search strategy is proposed as the reason for the differences. The finding that both older and younger individuals are not affected significantly by the presence of the irrelevant pop out distracter has implications in situations such as driving or hazard avoidance. In such scenarios, search performance is likely not impaired beyond what is found with distracters (visual clutter) in the environment. Copyright © 2013 Spanish General Council of Optometry. Published by Elsevier Espana. All rights reserved.

  5. The SeaView EarthCube project: Lessons Learned from Integrating Across Repositories

    Science.gov (United States)

    Diggs, S. C.; Stocks, K. I.; Arko, R. A.; Kinkade, D.; Shepherd, A.; Olson, C. J.; Pham, A.

    2017-12-01

    SeaView is an NSF-funded EarthCube Integrative Activity Project working with 5 existing data repositories* to provide oceanographers with highly integrated thematic data collections in user-requested formats. The project has three complementary goals: Supporting Scientists: SeaView targets scientists' need for easy access to data of interest that are ready to import into their preferred tool. Strengthening Repositories: By integrating data from multiple repositories for science use, SeaView is helping the ocean data repositories align their data and processes and make ocean data more accessible and easily integrated. Informing EarthCube (earthcube.org): SeaView's experience as an integration demonstration can inform the larger NSF EarthCube architecture and design effort. The challenges faced in this small-scale effort are informative to geosciences cyberinfrastructure more generally. Here we focus on the lessons learned that may inform other data facilities and integrative architecture projects. (The SeaView data collections will be presented at the Ocean Sciences 2018 meeting.) One example is the importance of shared semantics, with persistent identifiers, for key integration elements across the data sets (e.g. cruise, parameter, and project/program.) These must allow for revision through time and should have an agreed authority or process for resolving conflicts: aligning identifiers and correcting errors were time consuming and often required both deep domain knowledge and "back end" knowledge of the data facilities. Another example is the need for robust provenance, and tools that support automated or semi-automated data transform pipelines that capture provenance. Multiple copies and versions of data are now flowing into repositories, and onward to long-term archives such as NOAA NCEI and umbrella portals such as DataONE. Exact copies can be identified with hashes (for those that have the skills), but it can be painfully difficult to understand the processing

  6. Diviner lunar radiometer gridded brightness temperatures from geodesic binning of modeled fields of view

    Science.gov (United States)

    Sefton-Nash, E.; Williams, J.-P.; Greenhagen, B. T.; Aye, K.-M.; Paige, D. A.

    2017-12-01

    An approach is presented to efficiently produce high quality gridded data records from the large, global point-based dataset returned by the Diviner Lunar Radiometer Experiment aboard NASA's Lunar Reconnaissance Orbiter. The need to minimize data volume and processing time in production of science-ready map products is increasingly important with the growth in data volume of planetary datasets. Diviner makes on average >1400 observations per second of radiance that is reflected and emitted from the lunar surface, using 189 detectors divided into 9 spectral channels. Data management and processing bottlenecks are amplified by modeling every observation as a probability distribution function over the field of view, which can increase the required processing time by 2-3 orders of magnitude. Geometric corrections, such as projection of data points onto a digital elevation model, are numerically intensive and therefore it is desirable to perform them only once. Our approach reduces bottlenecks through parallel binning and efficient storage of a pre-processed database of observations. Database construction is via subdivision of a geodesic icosahedral grid, with a spatial resolution that can be tailored to suit the field of view of the observing instrument. Global geodesic grids with high spatial resolution are normally impractically memory intensive. We therefore demonstrate a minimum storage and highly parallel method to bin very large numbers of data points onto such a grid. A database of the pre-processed and binned points is then used for production of mapped data products that is significantly faster than if unprocessed points were used. We explore quality controls in the production of gridded data records by conditional interpolation, allowed only where data density is sufficient. The resultant effects on the spatial continuity and uncertainty in maps of lunar brightness temperatures is illustrated. We identify four binning regimes based on trades between the

  7. Directional Wide-Angle Range Finder (DWARF)

    Data.gov (United States)

    National Aeronautics and Space Administration — The proposed innovation, the Directional Wide-Angle Range Finder (DWARF) is the creation of a laser range-finder with a wide field-of-view (FOV) and a directional...

  8. Modeling The Atmosphere In The Era Of Big Data From Extremely Wide Field-Of-View Telescopes

    Science.gov (United States)

    Gonzalez Quiles, Junellie; Nordin, Jakob

    2018-01-01

    Surveys like the Sloan Digital Sky Survey (SDSS), Pan-STARRS and the Palomar Transient Factory Survey (PTF) receive large amounts of data, which need to be processed and calibrated in order to correct for various factors. One of the limiting factors in obtaining high quality data is the atmosphere, and it is therefore essential to find the appropriate calibration for the atmospheric extinction. It is to be expected that a physical atmospheric model, compared to a photometric calibration used currently by PTF, is more effective in calibrating for the atmospheric extinction due to its ability to account for rapid atmospheric fluctuation and objects of different colors. We focused on creating tools to model the atmospheric extinction for the upcoming Zwicky Transient Factory Survey (ZTF). In order to model the atmosphere, we created a program that combines input data and catalogue values, and efficiently handles them. Then, using PTF data and the SDSS catalogue, we created several models to fit the data, and tested the quality of the fits by chi-square minimization. This will allow us to optimize atmospheric extinction for the upcoming ZTF in the near future.

  9. Utilization of a Curved Local Surface Array in a 3.5m Wide field of View Telescope

    Science.gov (United States)

    2013-09-01

    about 150-µm. (Fig. 3d ). The second carrier was released, leaving a device about 200-µm thick overall, as shown Fig. 3e, and that could be diced for...station with two of 12 imagers during early alignment. This device provided 3D measurements of the individual CCD surfaces, as well as known fiducial...Fig. 10: The Zernike aberration terms are measured for a set of defocused images using algorithms based on associated yield loss with the

  10. Synchronized High-Speed Vision Sensor Network for Expansion of Field of View

    Directory of Open Access Journals (Sweden)

    Akihito Noda

    2018-04-01

    Full Text Available We propose a 500-frames-per-second high-speed vision (HSV sensor network that acquires frames at a timing that is precisely synchronized across the network. Multiple vision sensor nodes, individually comprising a camera and a PC, are connected via Ethernet for data transmission and for clock synchronization. A network of synchronized HSV sensors provides a significantly expanded field-of-view compared with that of each individual HSV sensor. In the proposed system, the shutter of each camera is controlled based on the clock of the PC locally provided inside the node, and the shutters are globally synchronized using the Precision Time Protocol (PTP over the network. A theoretical analysis and experiment results indicate that the shutter trigger skew among the nodes is a few tens of microseconds at most, which is significantly smaller than the frame interval of 1000-fps-class high-speed cameras. Experimental results obtained with the proposed system comprising four nodes demonstrated the ability to capture the propagation of a small displacement along a large-scale structure.

  11. Exploring field-of-view non-uniformities produced by a hand-held spectroradiometer

    Directory of Open Access Journals (Sweden)

    Tamir Caras

    2011-01-01

    Full Text Available The shape of a spectroradiometer’s field of view (FOV affects the way spectral measurements are acquired. Knowing this property is a prerequisite for the correct use of the spectrometer. If the substrate is heterogeneous, the ability to accurately know what is being measured depends on knowing the FOV location, shape, spectral and spatial sensitivity. The GER1500 is a hand-held spectrometer with a fixed lens light entry slit and has a laser guide that allows control over the target by positioning the entire unit. In the current study, the FOV of the GER1500 was mapped and analysed. The spectral and spatial non-uniformities of the FOV were examined and were found to be spectrally independent. The relationship between the FOV and the built-in laser guide was tested and found to have a linear displacement dependent on the distance to the target. This allows an accurate prediction of the actual FOV position. A correction method to improve the agreement between the expected and measured reflectance over heterogeneous targets was developed and validated. The methods described are applicable and may be of use with other hand-held spectroradiometers.

  12. Portable oral cancer detection using a miniature confocal imaging probe with a large field of view

    Science.gov (United States)

    Wang, Youmin; Raj, Milan; McGuff, H. Stan; Bhave, Gauri; Yang, Bin; Shen, Ting; Zhang, Xiaojing

    2012-06-01

    We demonstrate a MEMS micromirror enabled handheld confocal imaging probe for portable oral cancer detection, where a comparatively large field of view (FOV) was generated through the programmable Lissajous scanning pattern of the MEMS micromirror. Miniaturized handheld MEMS confocal imaging probe was developed, and further compared with the desktop confocal prototype under clinical setting. For the handheld confocal imaging system, optical design simulations using CODE VR® shows the lateral and axial resolution to be 0.98 µm and 4.2 µm, where experimental values were determined to be 3 µm and 5.8 µm, respectively, with a FOV of 280 µm×300 µm. Fast Lissajous imaging speed up to 2 fps was realized with improved Labview and Java based real-time imaging software. Properties such as 3D imaging through autofocusing and mosaic imaging for extended lateral view (6 mm × 8 mm) were examined for carcinoma real-time pathology. Neoplastic lesion tissues of giant cell fibroma and peripheral ossifying fibroma, the fibroma inside the paraffin box and ex vivo gross tissues were imaged by the bench-top and handheld imaging modalities, and further compared with commercial microscope imaging results. The MEMS scanner-based handheld confocal imaging probe shows great promise as a potential clinical tool for oral cancer diagnosis and treatment.

  13. Portable oral cancer detection using a miniature confocal imaging probe with a large field of view

    International Nuclear Information System (INIS)

    Wang, Youmin; Raj, Milan; Bhave, Gauri; Yang, Bin; Zhang, Xiaojing; McGuff, H. Stan; Shen, Ting

    2012-01-01

    We demonstrate a MEMS micromirror enabled handheld confocal imaging probe for portable oral cancer detection, where a comparatively large field of view (FOV) was generated through the programmable Lissajous scanning pattern of the MEMS micromirror. Miniaturized handheld MEMS confocal imaging probe was developed, and further compared with the desktop confocal prototype under clinical setting. For the handheld confocal imaging system, optical design simulations using CODE V R® shows the lateral and axial resolution to be 0.98 µm and 4.2 µm, where experimental values were determined to be 3 µm and 5.8 µm, respectively, with a FOV of 280 µm×300 µm. Fast Lissajous imaging speed up to 2 fps was realized with improved Labview and Java based real-time imaging software. Properties such as 3D imaging through autofocusing and mosaic imaging for extended lateral view (6 mm × 8 mm) were examined for carcinoma real-time pathology. Neoplastic lesion tissues of giant cell fibroma and peripheral ossifying fibroma, the fibroma inside the paraffin box and ex vivo gross tissues were imaged by the bench-top and handheld imaging modalities, and further compared with commercial microscope imaging results. The MEMS scanner-based handheld confocal imaging probe shows great promise as a potential clinical tool for oral cancer diagnosis and treatment. (paper)

  14. Mimicking honeybee eyes with a 280{sup 0} field of view catadioptric imaging system

    Energy Technology Data Exchange (ETDEWEB)

    Stuerzl, W; Boeddeker, N; Dittmar, L; Egelhaaf, M, E-mail: wolfgang.stuerzl@uni-bielefeld.d [Department of Neurobiology and Center of Excellence ' Cognitive Interaction Technology' , Bielefeld University (Germany)

    2010-09-15

    We present a small single camera imaging system that provides a continuous 280{sup 0} field of view (FOV) inspired by the large FOV of insect eyes. This is achieved by combining a curved reflective surface that is machined into acrylic glass with lenses covering the frontal field that otherwise would have been obstructed by the mirror. Based on the work of Seidl (1982 PhD Thesis Technische Hochschule Darmstadt), we describe an extension of the 'bee eye optics simulation' (BEOS) model by Giger (1996 PhD Thesis Australian National University) to the full FOV which enables us to remap camera images according to the spatial resolution of honeybee eyes. This model is also useful for simulating the visual input of a bee-like agent in a virtual environment. The imaging system in combination with our bee eye model can serve as a tool for assessing the visual world from a bee's perspective which is particularly helpful for experimental setups. It is also well suited for mobile robots, in particular on flying vehicles that need light-weight sensors.

  15. Designing a large field-of-view two-photon microscope using optical invariant analysis.

    Science.gov (United States)

    Bumstead, Jonathan R; Park, Jasmine J; Rosen, Isaac A; Kraft, Andrew W; Wright, Patrick W; Reisman, Matthew D; Côté, Daniel C; Culver, Joseph P

    2018-04-01

    Conventional two-photon microscopy (TPM) is capable of imaging neural dynamics with subcellular resolution, but it is limited to a field-of-view (FOV) diameter [Formula: see text]. Although there has been recent progress in extending the FOV in TPM, a principled design approach for developing large FOV TPM (LF-TPM) with off-the-shelf components has yet to be established. Therefore, we present a design strategy that depends on analyzing the optical invariant of commercially available objectives, relay lenses, mirror scanners, and emission collection systems in isolation. Components are then selected to maximize the space-bandwidth product of the integrated microscope. In comparison with other LF-TPM systems, our strategy simplifies the sequence of design decisions and is applicable to extending the FOV in any microscope with an optical relay. The microscope we constructed with this design approach can image [Formula: see text] lateral and [Formula: see text] axial resolution over a 7-mm diameter FOV, which is a 100-fold increase in FOV compared with conventional TPM. As a demonstration of the potential that LF-TPM has on understanding the microarchitecture of the mouse brain across interhemispheric regions, we performed in vivo imaging of both the cerebral vasculature and microglia cell bodies over the mouse cortex.

  16. Mimicking honeybee eyes with a 2800 field of view catadioptric imaging system

    International Nuclear Information System (INIS)

    Stuerzl, W; Boeddeker, N; Dittmar, L; Egelhaaf, M

    2010-01-01

    We present a small single camera imaging system that provides a continuous 280 0 field of view (FOV) inspired by the large FOV of insect eyes. This is achieved by combining a curved reflective surface that is machined into acrylic glass with lenses covering the frontal field that otherwise would have been obstructed by the mirror. Based on the work of Seidl (1982 PhD Thesis Technische Hochschule Darmstadt), we describe an extension of the 'bee eye optics simulation' (BEOS) model by Giger (1996 PhD Thesis Australian National University) to the full FOV which enables us to remap camera images according to the spatial resolution of honeybee eyes. This model is also useful for simulating the visual input of a bee-like agent in a virtual environment. The imaging system in combination with our bee eye model can serve as a tool for assessing the visual world from a bee's perspective which is particularly helpful for experimental setups. It is also well suited for mobile robots, in particular on flying vehicles that need light-weight sensors.

  17. Rapid portal imaging with a high-efficiency, large field-of-view detector.

    Science.gov (United States)

    Mosleh-Shirazi, M A; Evans, P M; Swindell, W; Symonds-Tayler, J R; Webb, S; Partridge, M

    1998-12-01

    The design, construction, and performance evaluation of an electronic portal imaging device (EPID) are described. The EPID has the same imaging geometry as the current mirror-based systems except for the x-ray detection stage, where a two-dimensional (2D) array of 1 cm thick CsI(Tl) detector elements are utilized. The approximately 18% x-ray quantum efficiency of the scintillation detector and its 30 x 40 cm2 field-of-view at the isocenter are greater than other area-imaging EPIDs. The imaging issues addressed are theoretical and measured signal-to-noise ratio, linearity of the imaging chain, influence of frame-summing on image quality and image calibration. Portal images of test objects and a humanoid phantom are used to measure the performance of the system. An image quality similar to the current devices is achieved but with a lower dose. With approximately 1 cGy dose delivered by a 6 MV beam, a 2 mm diam structure of 1.3% contrast and an 18 mm diam object of 0.125% contrast can be resolved without using image-enhancement methods. A spatial resolution of about 2 mm at the isocenter is demonstrated. The capability of the system to perform fast sequential imaging, synchronized with the radiation pulses, makes it suitable for patient motion studies and verification of intensity-modulated beams as well as its application in cone-beam megavoltage computed tomography.

  18. Can They See It? The Functional Field of View Is Narrower in Individuals with Autism Spectrum Disorder.

    Science.gov (United States)

    Song, Yongning; Hakoda, Yuji; Sanefuji, Wakako; Cheng, Chen

    2015-01-01

    Although social cognitive deficits have long been thought to underlie the characteristic and pervasive difficulties with social interaction observed in individuals with autism spectrum disorder (ASD), several recent behavioral and neuroimaging studies have indicated that visual perceptual impairments might also play a role. People with ASD show a robust bias towards detailed information at the expense of global information, although the mechanisms that underlie this phenomenon remain elusive. To address this issue, we investigated the functional field of view in a group of high-functioning children with autism (n = 13) and a paired non-ASD group (n = 13). Our results indicate that the ability to correctly detect and identify stimuli sharply decreases with greater eccentricity from the fovea in people with ASD. Accordingly, a probe analysis revealed that the functional field of view in the ASD group was only about 6.62° of retinal eccentricity, compared with 8.57° in typically developing children. Thus, children with ASD appear to have a narrower functional field of view. These results challenge the conventional hypothesis that the deficit in global processing in individuals with ASD is solely due to weak central coherence. Alternatively, our data suggest that a narrower functional field of view may also contribute to this bias.

  19. Can They See It? The Functional Field of View Is Narrower in Individuals with Autism Spectrum Disorder.

    Directory of Open Access Journals (Sweden)

    Yongning Song

    Full Text Available Although social cognitive deficits have long been thought to underlie the characteristic and pervasive difficulties with social interaction observed in individuals with autism spectrum disorder (ASD, several recent behavioral and neuroimaging studies have indicated that visual perceptual impairments might also play a role. People with ASD show a robust bias towards detailed information at the expense of global information, although the mechanisms that underlie this phenomenon remain elusive. To address this issue, we investigated the functional field of view in a group of high-functioning children with autism (n = 13 and a paired non-ASD group (n = 13. Our results indicate that the ability to correctly detect and identify stimuli sharply decreases with greater eccentricity from the fovea in people with ASD. Accordingly, a probe analysis revealed that the functional field of view in the ASD group was only about 6.62° of retinal eccentricity, compared with 8.57° in typically developing children. Thus, children with ASD appear to have a narrower functional field of view. These results challenge the conventional hypothesis that the deficit in global processing in individuals with ASD is solely due to weak central coherence. Alternatively, our data suggest that a narrower functional field of view may also contribute to this bias.

  20. Adaptive Scanning Optical Microscope (ASOM): A multidisciplinary optical microscope design for large field of view and high resolution imaging

    NARCIS (Netherlands)

    Potsaid, B.; Bellouard, Y.J.; Wen, J.T.

    2005-01-01

    From micro-assembly to biological observation, the optical microscope remains one of the most important tools for observing below the threshold of the naked human eye. However, in its conventional form, it suffers from a trade-off between resolution and field of view. This paper presents a new

  1. A meta-analysis of perceptual and cognitive functions involved in useful-field-of-view test performance

    NARCIS (Netherlands)

    Woutersen, K.; Guadron Palma, L.M.; Berg, A.V. van den; Boonstra, F.N.; Theelen, T.; Goossens, J.

    2017-01-01

    The useful-field-of-view (UFOV) test measures the amount of information someone can extract from a visual scene in one glance. Its scores show relatively strong relationships with everyday activities. The UFOV test consists of three computer tests, suggested to measure processing speed and central

  2. Relationship Between Motor Vehicle Collisions and Results of Perimetry, Useful Field of View, and Driving Simulation in Drivers With Glaucoma

    NARCIS (Netherlands)

    Tatham, AJ; Boer, E.R.; Gracitelli, CPB; Rosen, PN; Medeiros, FA

    2015-01-01

    Purpose: To examine the relationship between Motor Vehicle Collisions (MVCs) in
    drivers with glaucoma and standard automated perimetry (SAP), Useful Field of View
    (UFOV), and driving simulator assessment of divided attention.
    Methods: A cross-sectional study of 153 drivers from the

  3. Error Analysis and Calibration Method of a Multiple Field-of-View Navigation System.

    Science.gov (United States)

    Shi, Shuai; Zhao, Kaichun; You, Zheng; Ouyang, Chenguang; Cao, Yongkui; Wang, Zhenzhou

    2017-03-22

    The Multiple Field-of-view Navigation System (MFNS) is a spacecraft subsystem built to realize the autonomous navigation of the Spacecraft Inside Tiangong Space Station. This paper introduces the basics of the MFNS, including its architecture, mathematical model and analysis, and numerical simulation of system errors. According to the performance requirement of the MFNS, the calibration of both intrinsic and extrinsic parameters of the system is assumed to be essential and pivotal. Hence, a novel method based on the geometrical constraints in object space, called checkerboard-fixed post-processing calibration (CPC), is proposed to solve the problem of simultaneously obtaining the intrinsic parameters of the cameras integrated in the MFNS and the transformation between the MFNS coordinate and the cameras' coordinates. This method utilizes a two-axis turntable and a prior alignment of the coordinates is needed. Theoretical derivation and practical operation of the CPC method are introduced. The calibration experiment results of the MFNS indicate that the extrinsic parameter accuracy of the CPC reaches 0.1° for each Euler angle and 0.6 mm for each position vector component (1σ). A navigation experiment verifies the calibration result and the performance of the MFNS. The MFNS is found to work properly, and the accuracy of the position vector components and Euler angle reaches 1.82 mm and 0.17° (1σ) respectively. The basic mechanism of the MFNS may be utilized as a reference for the design and analysis of multiple-camera systems. Moreover, the calibration method proposed has practical value for its convenience for use and potential for integration into a toolkit.

  4. The useful field of view assessment predicts simulated commercial motor vehicle driving safety.

    Science.gov (United States)

    McManus, Benjamin; Heaton, Karen; Vance, David E; Stavrinos, Despina

    2016-10-02

    The Useful Field of View (UFOV) assessment, a measure of visual speed of processing, has been shown to be a predictive measure of motor vehicle collision (MVC) involvement in an older adult population, but it remains unknown whether UFOV predicts commercial motor vehicle (CMV) driving safety during secondary task engagement. The purpose of this study is to determine whether the UFOV assessment predicts simulated MVCs in long-haul CMV drivers. Fifty licensed CMV drivers (Mage = 39.80, SD = 8.38, 98% male, 56% Caucasian) were administered the 3-subtest version of the UFOV assessment, where lower scores measured in milliseconds indicated better performance. CMV drivers completed 4 simulated drives, each spanning approximately a 22.50-mile distance. Four secondary tasks were presented to participants in a counterbalanced order during the drives: (a) no secondary task, (b) cell phone conversation, (c) text messaging interaction, and (d) e-mailing interaction with an on-board dispatch device. The selective attention subtest significantly predicted simulated MVCs regardless of secondary task. Each 20 ms slower on subtest 3 was associated with a 25% increase in the risk of an MVC in the simulated drive. The e-mail interaction secondary task significantly predicted simulated MVCs with a 4.14 times greater risk of an MVC compared to the no secondary task condition. Subtest 3, a measure of visual speed of processing, significantly predicted MVCs in the email interaction task. Each 20 ms slower on subtest 3 was associated with a 25% increase in the risk of an MVC during the email interaction task. The UFOV subtest 3 may be a promising measure to identify CMV drivers who may be at risk for MVCs or in need of cognitive training aimed at improving speed of processing. Subtest 3 may also identify CMV drivers who are particularly at risk when engaged in secondary tasks while driving.

  5. Increasing the field of view of adaptive optics scanning laser ophthalmoscopy.

    Science.gov (United States)

    Laslandes, Marie; Salas, Matthias; Hitzenberger, Christoph K; Pircher, Michael

    2017-11-01

    An adaptive optics scanning laser ophthalmoscope (AO-SLO) set-up with two deformable mirrors (DM) is presented. It allows high resolution imaging of the retina on a 4°×4° field of view (FoV), considering a 7 mm pupil diameter at the entrance of the eye. Imaging on such a FoV, which is larger compared to classical AO-SLO instruments, is allowed by the use of the two DMs. The first DM is located in a plane that is conjugated to the pupil of the eye and corrects for aberrations that are constant in the FoV. The second DM is conjugated to a plane that is located ∼0.7 mm anterior to the retina. This DM corrects for anisoplanatism effects within the FoV. The control of the DMs is performed by combining the classical AO technique, using a Shack-Hartmann wave-front sensor, and sensorless AO, which uses a criterion characterizing the image quality. The retinas of four healthy volunteers were imaged in-vivo with the developed instrument. In order to assess the performance of the set-up and to demonstrate the benefits of the 2 DM configuration, the acquired images were compared with images taken in conventional conditions, on a smaller FoV and with only one DM. Moreover, an image of a larger patch of the retina was obtained by stitching of 9 images acquired with a 4°×4° FoV, resulting in a total FoV of 10°×10°. Finally, different retinal layers were imaged by shifting the focal plane.

  6. Methods for improving limited field-of-view radiotherapy reconstructions using imperfect a priori images

    International Nuclear Information System (INIS)

    Ruchala, Kenneth J.; Olivera, Gustavo H.; Kapatoes, Jeffrey M.; Reckwerdt, Paul J.; Mackie, Thomas R.

    2002-01-01

    There are many benefits to having an online CT imaging system for radiotherapy, as it helps identify changes in the patient's position and anatomy between the time of planning and treatment. However, many current online CT systems suffer from a limited field-of-view (LFOV) in that collected data do not encompass the patient's complete cross section. Reconstruction of these data sets can quantitatively distort the image values and introduce artifacts. This work explores the use of planning CT data as a priori information for improving these reconstructions. Methods are presented to incorporate this data by aligning the LFOV with the planning images and then merging the data sets in sinogram space. One alignment option is explicit fusion, producing fusion-aligned reprojection (FAR) images. For cases where explicit fusion is not viable, FAR can be implemented using the implicit fusion of normal setup error, referred to as normal-error-aligned reprojection (NEAR). These methods are evaluated for multiday patient images showing both internal and skin-surface anatomical variation. The iterative use of NEAR and FAR is also investigated, as are applications of NEAR and FAR to dose calculations and the compensation of LFOV online MVCT images with kVCT planning images. Results indicate that NEAR and FAR can utilize planning CT data as imperfect a priori information to reduce artifacts and quantitatively improve images. These benefits can also increase the accuracy of dose calculations and be used for augmenting CT images (e.g., MVCT) acquired at different energies than the planning CT

  7. Useful field of view predicts driving in the presence of distracters.

    Science.gov (United States)

    Wood, Joanne M; Chaparro, Alex; Lacherez, Philippe; Hickson, Louise

    2012-04-01

    The Useful Field of View (UFOV) test has been shown to be highly effective in predicting crash risk among older adults. An important question which we examined in this study is whether this association is due to the ability of the UFOV to predict difficulties in attention-demanding driving situations that involve either visual or auditory distracters. Participants included 92 community-living adults (mean age 73.6 ± 5.4 years; range 65-88 years) who completed all three subtests of the UFOV involving assessment of visual processing speed (subtest 1), divided attention (subtest 2), and selective attention (subtest 3); driving safety risk was also classified using the UFOV scoring system. Driving performance was assessed separately on a closed-road circuit while driving under three conditions: no distracters, visual distracters, and auditory distracters. Driving outcome measures included road sign recognition, hazard detection, gap perception, time to complete the course, and performance on the distracter tasks. Those rated as safe on the UFOV (safety rating categories 1 and 2), as well as those responding faster than the recommended cut-off on the selective attention subtest (350 msec), performed significantly better in terms of overall driving performance and also experienced less interference from distracters. Of the three UFOV subtests, the selective attention subtest best predicted overall driving performance in the presence of distracters. Older adults who were rated as higher risk on the UFOV, particularly on the selective attention subtest, demonstrated poorest driving performance in the presence of distracters. This finding suggests that the selective attention subtest of the UFOV may be differentially more effective in predicting driving difficulties in situations of divided attention which are commonly associated with crashes.

  8. Impairing the useful field of view in natural scenes: Tunnel vision versus general interference.

    Science.gov (United States)

    Ringer, Ryan V; Throneburg, Zachary; Johnson, Aaron P; Kramer, Arthur F; Loschky, Lester C

    2016-01-01

    A fundamental issue in visual attention is the relationship between the useful field of view (UFOV), the region of visual space where information is encoded within a single fixation, and eccentricity. A common assumption is that impairing attentional resources reduces the size of the UFOV (i.e., tunnel vision). However, most research has not accounted for eccentricity-dependent changes in spatial resolution, potentially conflating fixed visual properties with flexible changes in visual attention. Williams (1988, 1989) argued that foveal loads are necessary to reduce the size of the UFOV, producing tunnel vision. Without a foveal load, it is argued that the attentional decrement is constant across the visual field (i.e., general interference). However, other research asserts that auditory working memory (WM) loads produce tunnel vision. To date, foveal versus auditory WM loads have not been compared to determine if they differentially change the size of the UFOV. In two experiments, we tested the effects of a foveal (rotated L vs. T discrimination) task and an auditory WM (N-back) task on an extrafoveal (Gabor) discrimination task. Gabor patches were scaled for size and processing time to produce equal performance across the visual field under single-task conditions, thus removing the confound of eccentricity-dependent differences in visual sensitivity. The results showed that although both foveal and auditory loads reduced Gabor orientation sensitivity, only the foveal load interacted with retinal eccentricity to produce tunnel vision, clearly demonstrating task-specific changes to the form of the UFOV. This has theoretical implications for understanding the UFOV.

  9. Fast, large field-of-view, telecentric optical-CT scanning system for 3D radiochromic dosimetry

    Energy Technology Data Exchange (ETDEWEB)

    Thomas, A; Oldham, M, E-mail: ast5@duke.ed [Department of Radiation Oncology, Duke University Medical Center, Durham, NC (United States)

    2010-11-01

    We describe initial experiences with an in-house, fast, large field-of-view optical-CT telecentric scanner (the Duke Large field of view Optical-CT Scanner (DLOS)). The DLOS system is designed to enable telecentric optical-CT imaging of dosimeters up to 24 cm in diameter with a spatial resolution of 1 mm{sup 3}, in approximately 10 minutes. These capabilities render the DLOS system a unique device at present. The system is a scaled up version of early prototypes in our lab. This scaling introduces several challenges, including the accurate measurement of a greatly increased range of light attenuation within the dosimeter, and the need to reduce even minor reflections and scattered light within the imaging chain. We present several corrections and techniques that enable accurate, low noise, 3D dosimetery with the DLOS system.

  10. Portable waveguide display system with a large field of view by integrating freeform elements and volume holograms.

    Science.gov (United States)

    Han, Jian; Liu, Juan; Yao, Xincheng; Wang, Yongtian

    2015-02-09

    A compact waveguide display system integrating freeform elements and volume holograms is presented here for the first time. The use of freeform elements can broaden the field of view, which limits the applications of a holographic waveguide. An optimized system can achieve a diagonal field of view of 45° when the thickness of the waveguide planar is 3mm. Freeform-elements in-coupler and the volume holograms out-coupler were designed in detail in our study, and the influence of grating configurations on diffraction efficiency was analyzed thoroughly. The off-axis aberrations were well compensated by the in-coupler and the diffraction efficiency of the optimized waveguide display system could reach 87.57%. With integrated design, stability and reliability of this monochromatic display system were achieved and the alignment of the system was easily controlled by the record of the volume holograms, which makes mass production possible.

  11. Multiple scattering corrections to the Beer-Lambert law. 2: Detector with a variable field of view.

    Science.gov (United States)

    Zardecki, A; Tam, W G

    1982-07-01

    The multiple scattering corrections to the Beer-Lambert law in the case of a detector with a variable field of view are analyzed. We introduce transmission functions relating the received radiant power to reference power levels relevant to two different experimental situations. In the first case, the transmission function relates the received power to a reference power level appropriate to a nonattenuating medium. In the second case, the reference power level is established by bringing the receiver to the close-up position with respect to the source. To examine the effect of the variation of the detector field of view the behavior of the gain factor is studied. Numerical results modeling the laser beam propagation in fog, cloud, and rain are presented.

  12. About microlensing optical depth and rates for free-floating planets towards the Kepler's field of view

    International Nuclear Information System (INIS)

    Hafizi, M; Hamolli, L

    2012-01-01

    In this work we examine the possibility of observing microlensing events in the Kepler space observatory field of view, caused by brown dwarfs or free-floating planets. We calculate the optical depth towards the field of view of the Kepler satellite and the rate of these events based on latest results about mass distribution of astrophysical objects from brown dwarf down to Earth mass order. With the current data, the probability of such events is insignificant, due to the small number of stars observed by this instrument compared to other experiments devoted to the microlensing method. Nevertheless, this probability may increase significantly in the case of a higher presence of free-floating planets, whose number is poorly defined so far.

  13. Fusion of Data from Heterogeneous Sensors with Distributed Fields of View and Situation Evaluation for Advanced Driver Assistance Systems

    OpenAIRE

    Otto, Carola

    2013-01-01

    In order to develop a driver assistance system for pedestrian protection, pedestrians in the environment of a truck are detected by radars and a camera and are tracked across distributed fields of view using a Joint Integrated Probabilistic Data Association filter. A robust approach for prediction of the system vehicles trajectory is presented. It serves the computation of a probabilistic collision risk based on reachable sets where different sources of uncertainty are taken into account.

  14. Calibrating convective properties of solar-like stars in the Kepler field of view

    NARCIS (Netherlands)

    Bonaca, A.; Tanner, J.D.; Basu, S.; Chaplin, W.J.; Metcalfe, T.S.; Monteiro, M.J.P.F.G.; Ballot, J.; Bedding, T.R.; Bonanno, A.; Broomhall, A.M.; Bruntt, H.; Campante, T.L.; Christensen-Dalsgaard, J.; Corsaro, E.; Elsworth, Y.; García, R.A.; Hekker, S.; Karoff, C.; Kjeldsen, H.; Mathur, S.; Régulo, C.; Roxburgh, I.; Stello, D.; Trampedach, R.; Barclay, T.; Burke, C.J.; Caldwell, D.A.

    2012-01-01

    Stellar models generally use simple parameterizations to treat convection. The most widely used parameterization is the so-called mixing-length theory where the convective eddy sizes are described using a single number, α, the mixing-length parameter. This is a free parameter, and the general

  15. Thermal and ghost reflection modeling for a 180-deg. field-of-view long-wave infrared lens

    Science.gov (United States)

    Shi, Weimin; Couture, Michael E.

    2001-03-01

    Optics 1, Inc. has successfully designed and developed a 180 degree(s) field of view long wave infrared lens for USAF/AFRL under SBIR phase I and II funded projects in support of the multi-national Programmable Integrated Ordinance Suite (PIOS) program. In this paper, a procedure is presented on how to evaluate image degradation caused by asymmetric aerodynamic dome heating. In addition, a thermal gradient model is proposed to evaluate degradation caused by axial temperature gradient throughout the entire PIOS lens. Finally, a ghost reflection analysis is demonstrated with non-sequential model.

  16. Image quality assessment of three limited field-of-view cone-beam computed tomography devices in endodontics

    International Nuclear Information System (INIS)

    Tran, Michel

    2015-01-01

    Since the beginning of Cone Beam Computed Tomography (CBCT) in dento-maxillo-facial radiology, many CBCT devices with different technical aspects and characteristics were produced. Technical variations between CBCT and acquisition settings could involve image quality differences. In order to compare the performance of three limited field-of-view CBCT devices, an objective and subjective evaluation of image quality was carried out using an ex-vivo phantom, which combines both diagnostic and technical features. A significant difference in image quality was found between the five acquisition protocols of the study. (author) [fr

  17. Changes in Drivers’ Visual Performance during the Collision Avoidance Process as a Function of Different Field of Views at Intersections

    Science.gov (United States)

    Yan, Xuedong; Zhang, Xinran; Zhang, Yuting; Li, Xiaomeng; Yang, Zhuo

    2016-01-01

    The intersection field of view (IFOV) indicates an extent that the visual information can be observed by drivers. It has been found that further enhancing IFOV can significantly improve emergent collision avoidance performance at intersections, such as faster brake reaction time, smaller deceleration rate, and lower traffic crash involvement risk. However, it is not known how IFOV affects drivers’ eye movements, visual attention and the relationship between visual searching and traffic safety. In this study, a driving simulation experiment was conducted to uncover the changes in drivers’ visual performance during the collision avoidance process as a function of different field of views at an intersection by using an eye tracking system. The experimental results showed that drivers’ ability in identifying the potential hazard in terms of visual searching was significantly affected by different IFOV conditions. As the IFOVs increased, drivers had longer gaze duration (GD) and more number of gazes (NG) in the intersection surrounding areas and paid more visual attention to capture critical visual information on the emerging conflict vehicle, thus leading to a better collision avoidance performance and a lower crash risk. It was also found that female drivers had a better visual performance and a lower crash rate than male drivers. From the perspective of drivers’ visual performance, the results strengthened the evidence that further increasing intersection sight distance standards should be encouraged for enhancing traffic safety. PMID:27716824

  18. Preoperative staging of endometrial cancer using reduced field-of-view diffusion-weighted imaging: a preliminary study

    Energy Technology Data Exchange (ETDEWEB)

    Ota, Takashi; Hori, Masatoshi; Onishi, Hiromitsu; Sakane, Makoto; Tsuboyama, Takahiro; Tatsumi, Mitsuaki; Tomiyama, Noriyuki [Osaka University Graduate School of Medicine, Department of Diagnostic and Interventional Radiology, Suita, Osaka (Japan); Nakamoto, Atsushi; Narumi, Yoshifumi [Osaka Medical College, Department of Radiology, Osaka (Japan); Kimura, Tadashi [Osaka University Graduate School of Medicine, Department of Obstetrics and Gynaecology, Osaka (Japan)

    2017-12-15

    To compare the image quality and diagnostic performance of reduced field-of-view (rFOV) versus conventional full field-of-view (fFOV) diffusion-weighted (DW) imaging of endometrial cancer. Fifty women with endometrial cancer underwent preoperative rFOV and fFOV DW imaging. Two radiologists compared the image qualities of both techniques, and five radiologists assessed superficial and deep myometrial invasion using both techniques. The statistical analysis included the Wilcoxon signed-rank test and paired t-test for comparisons of image quality and mean diagnostic values. Distortion, tumour delineation, and overall image quality were significantly better with rFOV DW imaging, compared to fFOV DW imaging (P < 0.05); however, the former was inferior in noise (P < 0.05). Regarding superficial invasion, the mean accuracies of the techniques did not differ statistically (rFOV, 58.0% versus fFOV, 56.0%; P = 0.30). Regarding deep myometrial invasion, rFOV DW imaging yielded significantly better mean accuracy, specificity, and positive predictive values (88.4%, 97.8%, and 91.7%, respectively), compared with fFOV DW imaging (84.8%, 94.1%, and 77.4%, respectively; P = 0.009, 0.005, and 0.011, respectively). Compared with fFOV DW imaging, rFOV DW imaging yielded less distortion, improved image quality and, consequently, better diagnostic performance for deep myometrial invasion of endometrial cancer. (orig.)

  19. Magnetic resonance imaging in ophthalmic diagnosis. Results of examinations using a small field-of-view surface coil

    International Nuclear Information System (INIS)

    Kato, Yuji; Yoshida, Akitoshi; Kanno, Harumi; Ogasawara, Hironobu; Murakami, Noboru; Cheng, Hong-Ming.

    1997-01-01

    We obtained T 1 -and T 2 -weighted magnetic resonance (MR) images in 3 patients with vitreoretinal disorders using a recently developed surface coil that was inductively coupled and had a small field of view. On both T 1 -and T 2 -weighted images, tractional retinal detachment was clearly detected in the first patient, who had proliferative diabetic retinopathy. T 1 - and T 2 -weighted images of the second patient, who had total retinal detachment with proliferative vitreous retinopathy, revealed a funnel-shaped thickened retina. The third patient had postoperative rhegmatogenous retinal detachment with opacity due to postoperative cataract and intravitreous injection of gas; on this patient's MR images we could clearly differentiate the reattached retina, silicone used for scleral buckling, and intravitreous gas, even though these differentiations were not possible with ophthalmoscopy or B-scan ultrasonography. High resolution MR imaging with our technique can be performed in a short time and regardless of the eye's condition. Our findings strongly indicate that MRI with a small field-of-view surface coil is a useful tool for diagnosing various vitreoretinal disorders and observing pathological changes. (author)

  20. Is the size of the useful field of view affected by postural demands associated with standing and stepping?

    Science.gov (United States)

    Reed-Jones, James G; Reed-Jones, Rebecca J; Hollands, Mark A

    2014-04-30

    The useful field of view (UFOV) is the visual area from which information is obtained at a brief glance. While studies have examined the effects of increased cognitive load on the visual field, no one has specifically looked at the effects of postural control or locomotor activity on the UFOV. The current study aimed to examine the effects of postural demand and locomotor activity on UFOV performance in healthy young adults. Eleven participants were tested on three modified UFOV tasks (central processing, peripheral processing, and divided-attention) while seated, standing, and stepping in place. Across all postural conditions, participants showed no difference in their central or peripheral processing. However, in the divided-attention task (reporting the letter in central vision and target location in peripheral vision amongst distracter items) a main effect of posture condition on peripheral target accuracy was found for targets at 57° of eccentricity (p=.037). The mean accuracy reduced from 80.5% (standing) to 74% (seated) to 56.3% (stepping). These findings show that postural demands do affect UFOV divided-attention performance. In particular, the size of the useful field of view significantly decreases when stepping. This finding has important implications for how the results of a UFOV test are used to evaluate the general size of the UFOV during varying activities, as the traditional seated test procedure may overestimate the size of the UFOV during locomotor activities. Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.

  1. Traversing field of view and AR-PIV for mid-field wake vortex investigation in a towing tank

    Science.gov (United States)

    Scarano, F.; van Wijk, C.; Veldhuis, L. L. M.

    2002-08-01

    Wake vortex flow experiments are performed in a water tank where a 1:48 scaled model of a large transport aircraft A340-300 is towed at the speed of 3 and 5 ms-1 with values of the angle of attack α={2°, 4°, 8°}. Particle image velocimetry (PIV) measurements are performed in a plane perpendicular to the towing direction describing the streamwise component of the wake vorticity. The instantaneous field of view (I-FOV) is traversed vertically with an underwater moving-camera device tracking the vortex core during the downward motion. An adaptive resolution (AR) image-processing technique is introduced that enhances the PIV interrogation in terms of spatial resolution and accuracy. The main objectives of the investigation are to demonstrate the applicability of PIV diagnostics in wake vortex research with towing-tank facilities. The specific implementation of the traversing field-of-view (T-FOV) technique and the AR image processing are driven by the need to characterize the vortex wake global properties as well as the vortex decay phenomenon in the mid- and far-field. Relevant aerodynamic information is obtained in the mid-field where the time evolution of the vortex structure (core radius and tangential velocity) and of the overall vortex wake (vortex trajectory, descent velocity, circulation) are discussed.

  2. CALIBRATING CONVECTIVE PROPERTIES OF SOLAR-LIKE STARS IN THE KEPLER FIELD OF VIEW

    Energy Technology Data Exchange (ETDEWEB)

    Bonaca, Ana; Tanner, Joel D.; Basu, Sarbani [Department of Astronomy, Yale University, P.O. Box 208101, New Haven, CT 06520-8101 (United States); Chaplin, William J.; Metcalfe, Travis S.; Christensen-Dalsgaard, Jorgen; Garcia, Rafael A.; Mathur, Savita [Kavli Institute for Theoretical Physics, Kohn Hall, University of California, Santa Barbara, CA 93106 (United States); Monteiro, Mario J. P. F. G.; Campante, Tiago L. [Centro de Astrofisica and Faculdade de Ciencias, Universidade do Porto, Rua das Estrelas, 4150-762 Porto (Portugal); Ballot, Jerome [CNRS, Institut de Recherche en Astrophysique et Planetologie, 14 avenue Edouard Belin, F-31400 Toulouse (France); Bedding, Timothy R.; Corsaro, Enrico [Sydney Institute for Astronomy (SIfA), School of Physics, University of Sydney, NSW 2006 (Australia); Bonanno, Alfio [INAF-Osservatorio Astrofisico di Catania, Via S.Sofia 78, I-95123 Catania (Italy); Broomhall, Anne-Marie; Elsworth, Yvonne [School of Physics and Astronomy, University of Birmingham, Edgbaston, Birmingham, B15 2TT (United Kingdom); Bruntt, Hans; Karoff, Christoffer; Kjeldsen, Hans [Stellar Astrophysics Centre, Department of Physics and Astronomy, Aarhus University, DK-8000 Aarhus C (Denmark); Hekker, Saskia, E-mail: ana.bonaca@yale.edu, E-mail: sarbani.basu@yale.edu, E-mail: joel.tanner@yale.edu [Astronomical Institute Anton Pannekoek, University of Amsterdam, Science Park 904, 1098-XH Amsterdam (Netherlands); and others

    2012-08-10

    Stellar models generally use simple parameterizations to treat convection. The most widely used parameterization is the so-called mixing-length theory where the convective eddy sizes are described using a single number, {alpha}, the mixing-length parameter. This is a free parameter, and the general practice is to calibrate {alpha} using the known properties of the Sun and apply that to all stars. Using data from NASA's Kepler mission we show that using the solar-calibrated {alpha} is not always appropriate, and that in many cases it would lead to estimates of initial helium abundances that are lower than the primordial helium abundance. Kepler data allow us to calibrate {alpha} for many other stars and we show that for the sample of stars we have studied, the mixing-length parameter is generally lower than the solar value. We studied the correlation between {alpha} and stellar properties, and we find that {alpha} increases with metallicity. We therefore conclude that results obtained by fitting stellar models or by using population-synthesis models constructed with solar values of {alpha} are likely to have large systematic errors. Our results also confirm theoretical expectations that the mixing-length parameter should vary with stellar properties.

  3. Preliminary experience of a three-dimensional, large-field-of-view PET scanner for the localization of partial epilepsy

    International Nuclear Information System (INIS)

    Binns, D.S.; O'Brien, T.J.; Murphy, M.; Cook, M.J.; Hicks, R.J.

    1999-01-01

    Full text: PET scanning is a useful ancillary technique in the localization of intractable partial epilepsy, but its widespread use has been limited by the high cost of traditional PET equipment and radioisotopes. The use of 3D-scanning mode with a large-field of-view PET scanner involves lower equipment costs and requires significantly lower doses of radioisotope. Our aim was to report our preliminary experience of the use of a 3-D, large-field-of-view scanner for FDG-PET studies in the localization of partial epilepsy. 31 patients (pts) with partial epilepsy were studied. The FDG-PET scans were reviewed blindly by a single reviewer without knowledge of seizure localization on structural imaging or ictal electroencephalographic (EEG) monitoring. The PET results were correlated with the localization by more traditional techniques and the results on surgery when available. A localized region of hypometabolism on FDG-PET scanning was reported in 26/31 (84%) patients (21 temporal, 5 extratemporal). This compared favourably with volumetric MRI on which 19/31 (61%) had a focal potentially epileptogenic abnormality, all of which were concordant with the PET localization. PET was concordant with ictal EEG onset in all 22 patients with localizing studies, including 5 pts with normal MRI. PET demonstrated localized hypometabolism in 4/5 pts with non-localizing ictal EEG and was concordant in both pts with abnormal MRI in this group. PET was considered normal in 4 pts, including 3 pts with normal MRI but localizing EEG and 1 pt without EEG or MRI abnormality. One pt with a localizing EEG and normal MRI was felt to have bitemporal hypometabolism. Five patients have subsequently had resective epilepsy surgery with 4 currently seizure-free and 1 significantly improved. Four patients are planned for surgery in the near future. In conclusion, FDG-PET using a 3-D, large-field-of view PET scanner provides sensitive and specific localization in partial epilepsy, and may provide a

  4. Volumetric fluorescence retinal imaging in vivo over a 30-degree field of view by oblique scanning laser ophthalmoscopy (oSLO).

    Science.gov (United States)

    Zhang, Lei; Song, Weiye; Shao, Di; Zhang, Sui; Desai, Manishi; Ness, Steven; Roy, Sayon; Yi, Ji

    2018-01-01

    While fluorescent contrast is widely used in ophthalmology, three-dimensional (3D) fluorescence retinal imaging over a large field of view (FOV) has been challenging. In this paper, we describe a novel oblique scanning laser ophthalmoscopy (oSLO) technique that provides 3D volumetric fluorescence retinal imaging with only one raster scan. The technique utilizes scanned oblique illumination and angled detection to obtain fluorescent cross-sectional images, analogous to optical coherence tomography (OCT) line scans (or B-scans). By breaking the coaxial optical alignment used in conventional retinal imaging modalities, depth resolution is drastically improved. To demonstrate the capability of oSLO, we have performed in vivo volumetric fluorescein angiography (FA) of the rat retina with ~25μm depth resolution and over a 30° FOV. Using depth segmentation, oSLO can obtain high contrast images of the microvasculature down to single capillaries in 3D. The multi-modal nature of oSLO also allows for seamless combination with simultaneous OCT angiography.

  5. Automated Field-of-View, Illumination, and Recognition Algorithm Design of a Vision System for Pick-and-Place Considering Colour Information in Illumination and Images.

    Science.gov (United States)

    Chen, Yibing; Ogata, Taiki; Ueyama, Tsuyoshi; Takada, Toshiyuki; Ota, Jun

    2018-05-22

    Machine vision is playing an increasingly important role in industrial applications, and the automated design of image recognition systems has been a subject of intense research. This study has proposed a system for automatically designing the field-of-view (FOV) of a camera, the illumination strength and the parameters in a recognition algorithm. We formulated the design problem as an optimisation problem and used an experiment based on a hierarchical algorithm to solve it. The evaluation experiments using translucent plastics objects showed that the use of the proposed system resulted in an effective solution with a wide FOV, recognition of all objects and 0.32 mm and 0.4° maximal positional and angular errors when all the RGB (red, green and blue) for illumination and R channel image for recognition were used. Though all the RGB illumination and grey scale images also provided recognition of all the objects, only a narrow FOV was selected. Moreover, full recognition was not achieved by using only G illumination and a grey-scale image. The results showed that the proposed method can automatically design the FOV, illumination and parameters in the recognition algorithm and that tuning all the RGB illumination is desirable even when single-channel or grey-scale images are used for recognition.

  6. A multidimensional multigroup diffusion model for the determination of the frequency-dependent field of view of a neutron detector

    International Nuclear Information System (INIS)

    van der Hagen, T.H.J.J.; Hoogenboom, J.E.; van Dam, H.

    1992-01-01

    This paper reports on the sensitivity of a neutron detector to parametric fluctuations in the core of a reactor which depends on the position and the frequency of the perturbation. The basic neutron diffusion model for the calculation of this so-called field of view (FOV) of the detector is extended with respect to the dimensionality of the problem and the number of energy groups involved. The physical meaning of the FOV concept is illustrated by means of some simple examples, which can be handled analytically. The possibility of calculating the FOV by a conventional neutron diffusion code is demonstrated. In that case, the calculation in n neutron energy groups leads to 2n modified neutron diffusion equations

  7. The NIKA2 Large Field-of-View Millimeter Continuum Camera for the 30-M IRAM Telescope

    Science.gov (United States)

    Monfardini, Alessandro

    2018-01-01

    We have constructed and deployed a multi-thousands pixels dual-band (150 and 260 GHz, respectively 2mm and 1.15mm wavelengths) camera to image an instantaneous field-of-view of 6.5arc-min and configurable to map the linear polarization at 260GHz. We are providing a detailed description of this instrument, named NIKA2 (New IRAM KID Arrays 2), in particular focusing on the cryogenics, the optics, the focal plane arrays based on Kinetic Inductance Detectors (KID) and the readout electronics. We are presenting the performance measured on the sky during the commissioning runs that took place between October 2015 and April 2017 at the 30-meter IRAM (Institute of Millimetric Radio Astronomy) telescope at Pico Veleta, and preliminary science-grade results.

  8. Variation of linear and circular polarization persistence for changing field of view and collection area in a forward scattering environment

    Science.gov (United States)

    van der Laan, John D.; Wright, Jeremy B.; Scrymgeour, David A.; Kemme, Shanalyn A.; Dereniak, Eustace L.

    2016-05-01

    We present experimental and simulation results for a laboratory-based forward-scattering environment, where 1 μm diameter polystyrene spheres are suspended in water to model the optical scattering properties of fog. Circular polarization maintains its degree of polarization better than linear polarization as the optical thickness of the scattering environment increases. Both simulation and experiment quantify circular polarization's superior persistence, compared to that of linear polarization, and show that it is much less affected by variations in the field of view and collection area of the optical system. Our experimental environment's lateral extent was physically finite, causing a significant difference between measured and simulated degree of polarization values for incident linearly polarized light, but not for circularly polarized light. Through simulation we demonstrate that circular polarization is less susceptible to the finite environmental extent as well as the collection optic's limiting configuration.

  9. A spatio-temporally compensated acousto-optic scanner for two-photon microscopy providing large field of view.

    Science.gov (United States)

    Kremer, Y; Léger, J-F; Lapole, R; Honnorat, N; Candela, Y; Dieudonné, S; Bourdieu, L

    2008-07-07

    Acousto-optic deflectors (AOD) are promising ultrafast scanners for non-linear microscopy. Their use has been limited until now by their small scanning range and by the spatial and temporal dispersions of the laser beam going through the deflectors. We show that the use of AOD of large aperture (13mm) compared to standard deflectors allows accessing much larger field of view while minimizing spatio-temporal distortions. An acousto-optic modulator (AOM) placed at distance of the AOD is used to compensate spatial and temporal dispersions. Fine tuning of the AOM-AOD setup using a frequency-resolved optical gating (GRENOUILLE) allows elimination of pulse front tilt whereas spatial chirp is minimized thanks to the large aperture AOD.

  10. Wavefield back-propagation in high-resolution X-ray holography with a movable field of view.

    Science.gov (United States)

    Guehrs, Erik; Günther, Christian M; Pfau, Bastian; Rander, Torbjörn; Schaffert, Stefan; Schlotter, William F; Eisebitt, Stefan

    2010-08-30

    Mask-based Fourier transform holography is used to record images of biological objects with 2.2 nm X-ray wavelength. The holography mask and the object are decoupled from each other which allows us to move the field of view over a large area over the sample. Due to the separation of the mask and the sample on different X-ray windows, a gap between both windows in the micrometer range typically exists. Using standard Fourier transform holography, focussed images of the sample can directly be reconstructed only for gap distances within the setup's depth of field. Here, we image diatoms as function of the gap distance and demonstrate the possibility to recover focussed images via a wavefield back-propagation technique. The limitations of our approach with respect to large separations are mainly associated with deviations from flat-field illumination of the object.

  11. The NIKA2 large-field-of-view millimetre continuum camera for the 30 m IRAM telescope

    Science.gov (United States)

    Adam, R.; Adane, A.; Ade, P. A. R.; André, P.; Andrianasolo, A.; Aussel, H.; Beelen, A.; Benoît, A.; Bideaud, A.; Billot, N.; Bourrion, O.; Bracco, A.; Calvo, M.; Catalano, A.; Coiffard, G.; Comis, B.; De Petris, M.; Désert, F.-X.; Doyle, S.; Driessen, E. F. C.; Evans, R.; Goupy, J.; Kramer, C.; Lagache, G.; Leclercq, S.; Leggeri, J.-P.; Lestrade, J.-F.; Macías-Pérez, J. F.; Mauskopf, P.; Mayet, F.; Maury, A.; Monfardini, A.; Navarro, S.; Pascale, E.; Perotto, L.; Pisano, G.; Ponthieu, N.; Revéret, V.; Rigby, A.; Ritacco, A.; Romero, C.; Roussel, H.; Ruppin, F.; Schuster, K.; Sievers, A.; Triqueneaux, S.; Tucker, C.; Zylka, R.

    2018-01-01

    Context. Millimetre-wave continuum astronomy is today an indispensable tool for both general astrophysics studies (e.g. star formation, nearby galaxies) and cosmology (e.g. cosmic microwave background and high-redshift galaxies). General purpose, large-field-of-view instruments are needed to map the sky at intermediate angular scales not accessible by the high-resolution interferometers (e.g. ALMA in Chile, NOEMA in the French Alps) and by the coarse angular resolution space-borne or ground-based surveys (e.g. Planck, ACT, SPT). These instruments have to be installed at the focal plane of the largest single-dish telescopes, which are placed at high altitude on selected dry observing sites. In this context, we have constructed and deployed a three-thousand-pixel dual-band (150 GHz and 260 GHz, respectively 2 mm and 1.15 mm wavelengths) camera to image an instantaneous circular field-of-view of 6.5 arcmin in diameter, and configurable to map the linear polarisation at 260 GHz. Aims: First, we are providing a detailed description of this instrument, named NIKA2 (New IRAM KID Arrays 2), in particular focussing on the cryogenics, optics, focal plane arrays based on Kinetic Inductance Detectors, and the readout electronics. The focal planes and part of the optics are cooled down to the nominal 150 mK operating temperature by means of an adhoc dilution refrigerator. Secondly, we are presenting the performance measured on the sky during the commissioning runs that took place between October 2015 and April 2017 at the 30-m IRAM telescope at Pico Veleta, near Granada (Spain). Methods: We have targeted a number of astronomical sources. Starting from beam-maps on primary and secondary calibrators we have then gone to extended sources and faint objects. Both internal (electronic) and on-the-sky calibrations are applied. The general methods are described in the present paper. Results: NIKA2 has been successfully deployed and commissioned, performing in-line with expectations. In

  12. A Variational Method to Retrieve the Extinction Profile in Liquid Clouds Using Multiple Field-of-View Lidar

    Science.gov (United States)

    Pounder, Nicola L.; Hogan, Robin J.; Varnai, Tamas; Battaglia, Alessandro; Cahalan, Robert F.

    2011-01-01

    While liquid clouds playa very important role in the global radiation budget, it's been very difficult to remotely determine their internal cloud structure. Ordinary lidar instruments (similar to radars but using visible light pulses) receive strong signals from such clouds, but the information is limited to a thin layer near the cloud boundary. Multiple field-of-view (FOV) lidars offer some new hope as they are able to isolate photons that were scattered many times by cloud droplets and penetrated deep into a cloud before returning to the instrument. Their data contains new information on cloud structure, although the lack of fast simulation methods made it challenging to interpret the observations. This paper describes a fast new technique that can simulate multiple-FOV lidar signals and can even estimate the way the signals would change in response to changes in cloud properties-an ability that allows quick refinements in our initial guesses of cloud structure. Results for a hypothetical airborne three-FOV lidar suggest that this approach can help determine cloud structure for a deeper layer in clouds, and can reliably determine the optical thickness of even fairly thick liquid clouds. The algorithm is also applied to stratocumulus observations by the 8-FOV airborne "THOR" lidar. These tests demonstrate that the new method can determine the depth to which a lidar provides useful information on vertical cloud structure. This work opens the way to exploit data from spaceborne lidar and radar more rigorously than has been possible up to now.

  13. How do field of view and resolution affect the information content of panoramic scenes for visual navigation? A computational investigation.

    Science.gov (United States)

    Wystrach, Antoine; Dewar, Alex; Philippides, Andrew; Graham, Paul

    2016-02-01

    The visual systems of animals have to provide information to guide behaviour and the informational requirements of an animal's behavioural repertoire are often reflected in its sensory system. For insects, this is often evident in the optical array of the compound eye. One behaviour that insects share with many animals is the use of learnt visual information for navigation. As ants are expert visual navigators it may be that their vision is optimised for navigation. Here we take a computational approach in asking how the details of the optical array influence the informational content of scenes used in simple view matching strategies for orientation. We find that robust orientation is best achieved with low-resolution visual information and a large field of view, similar to the optical properties seen for many ant species. A lower resolution allows for a trade-off between specificity and generalisation for stored views. Additionally, our simulations show that orientation performance increases if different portions of the visual field are considered as discrete visual sensors, each giving an independent directional estimate. This suggests that ants might benefit by processing information from their two eyes independently.

  14. MR-based field-of-view extension in MR/PET: B0 homogenization using gradient enhancement (HUGE).

    Science.gov (United States)

    Blumhagen, Jan O; Ladebeck, Ralf; Fenchel, Matthias; Scheffler, Klaus

    2013-10-01

    In whole-body MR/PET, the human attenuation correction can be based on the MR data. However, an MR-based field-of-view (FoV) is limited due to physical restrictions such as B0 inhomogeneities and gradient nonlinearities. Therefore, for large patients, the MR image and the attenuation map might be truncated and the attenuation correction might be biased. The aim of this work is to explore extending the MR FoV through B0 homogenization using gradient enhancement in which an optimal readout gradient field is determined to locally compensate B0 inhomogeneities and gradient nonlinearities. A spin-echo-based sequence was developed that computes an optimal gradient for certain regions of interest, for example, the patient's arms. A significant distortion reduction was achieved outside the normal MR-based FoV. This FoV extension was achieved without any hardware modifications. In-plane distortions in a transaxially extended FoV of up to 600 mm were analyzed in phantom studies. In vivo measurements of the patient's arms lying outside the normal specified FoV were compared with and without the use of B0 homogenization using gradient enhancement. In summary, we designed a sequence that provides data for reducing the image distortions due to B0 inhomogeneities and gradient nonlinearities and used the data to extend the MR FoV. Copyright © 2011 Wiley Periodicals, Inc.

  15. Large field of view quantitative phase imaging of induced pluripotent stem cells and optical pathlength reference materials

    Science.gov (United States)

    Kwee, Edward; Peterson, Alexander; Stinson, Jeffrey; Halter, Michael; Yu, Liya; Majurski, Michael; Chalfoun, Joe; Bajcsy, Peter; Elliott, John

    2018-02-01

    Induced pluripotent stem cells (iPSCs) are reprogrammed cells that can have heterogeneous biological potential. Quality assurance metrics of reprogrammed iPSCs will be critical to ensure reliable use in cell therapies and personalized diagnostic tests. We present a quantitative phase imaging (QPI) workflow which includes acquisition, processing, and stitching multiple adjacent image tiles across a large field of view (LFOV) of a culture vessel. Low magnification image tiles (10x) were acquired with a Phasics SID4BIO camera on a Zeiss microscope. iPSC cultures were maintained using a custom stage incubator on an automated stage. We implement an image acquisition strategy that compensates for non-flat illumination wavefronts to enable imaging of an entire well plate, including the meniscus region normally obscured in Zernike phase contrast imaging. Polynomial fitting and background mode correction was implemented to enable comparability and stitching between multiple tiles. LFOV imaging of reference materials indicated that image acquisition and processing strategies did not affect quantitative phase measurements across the LFOV. Analysis of iPSC colony images demonstrated mass doubling time was significantly different than area doubling time. These measurements were benchmarked with prototype microsphere beads and etched-glass gratings with specified spatial dimensions designed to be QPI reference materials with optical pathlength shifts suitable for cell microscopy. This QPI workflow and the use of reference materials can provide non-destructive traceable imaging method for novel iPSC heterogeneity characterization.

  16. Global calibration of multi-cameras with non-overlapping fields of view based on photogrammetry and reconfigurable target

    Science.gov (United States)

    Xia, Renbo; Hu, Maobang; Zhao, Jibin; Chen, Songlin; Chen, Yueling

    2018-06-01

    Multi-camera vision systems are often needed to achieve large-scale and high-precision measurement because these systems have larger fields of view (FOV) than a single camera. Multiple cameras may have no or narrow overlapping FOVs in many applications, which pose a huge challenge to global calibration. This paper presents a global calibration method for multi-cameras without overlapping FOVs based on photogrammetry technology and a reconfigurable target. Firstly, two planar targets are fixed together and made into a long target according to the distance between the two cameras to be calibrated. The relative positions of the two planar targets can be obtained by photogrammetric methods and used as invariant constraints in global calibration. Then, the reprojection errors of target feature points in the two cameras’ coordinate systems are calculated at the same time and optimized by the Levenberg–Marquardt algorithm to find the optimal solution of the transformation matrix between the two cameras. Finally, all the camera coordinate systems are converted to the reference coordinate system in order to achieve global calibration. Experiments show that the proposed method has the advantages of high accuracy (the RMS error is 0.04 mm) and low cost and is especially suitable for on-site calibration.

  17. Small Field of View Scintimammography Gamma Camera Integrated to a Stereotactic Core Biopsy Digital X-ray System

    Energy Technology Data Exchange (ETDEWEB)

    Andrew Weisenberger; Fernando Barbosa; T. D. Green; R. Hoefer; Cynthia Keppel; Brian Kross; Stanislaw Majewski; Vladimir Popov; Randolph Wojcik

    2002-10-01

    A small field of view gamma camera has been developed for integration with a commercial stereotactic core biopsy system. The goal is to develop and implement a dual-modality imaging system utilizing scintimammography and digital radiography to evaluate the reliability of scintimammography in predicting the malignancy of suspected breast lesions from conventional X-ray mammography. The scintimammography gamma camera is a custom-built mini gamma camera with an active area of 5.3 cm /spl times/ 5.3 cm and is based on a 2 /spl times/ 2 array of Hamamatsu R7600-C8 position-sensitive photomultiplier tubes. The spatial resolution of the gamma camera at the collimator surface is < 4 mm full-width at half-maximum and a sensitivity of /spl sim/ 4000 Hz/mCi. The system is also capable of acquiring dynamic scintimammographic data to allow for dynamic uptake studies. Sample images of preliminary clinical results are presented to demonstrate the performance of the system.

  18. Is Visual Selective Attention in Deaf Individuals Enhanced or Deficient? The Case of the Useful Field of View

    Science.gov (United States)

    Dye, Matthew W. G.; Hauser, Peter C.; Bavelier, Daphne

    2009-01-01

    Background Early deafness leads to enhanced attention in the visual periphery. Yet, whether this enhancement confers advantages in everyday life remains unknown, as deaf individuals have been shown to be more distracted by irrelevant information in the periphery than their hearing peers. Here, we show that, in a complex attentional task, a performance advantage results for deaf individuals. Methodology/Principal Findings We employed the Useful Field of View (UFOV) which requires central target identification concurrent with peripheral target localization in the presence of distractors – a divided, selective attention task. First, the comparison of deaf and hearing adults with or without sign language skills establishes that deafness and not sign language use drives UFOV enhancement. Second, UFOV performance was enhanced in deaf children, but only after 11 years of age. Conclusions/Significance This work demonstrates that, following early auditory deprivation, visual attention resources toward the periphery slowly get augmented to eventually result in a clear behavioral advantage by pre-adolescence on a selective visual attention task. PMID:19462009

  19. A meta-analysis of perceptual and cognitive functions involved in useful-field-of-view test performance.

    Science.gov (United States)

    Woutersen, Karlijn; Guadron, Leslie; van den Berg, Albert V; Boonstra, F Nienke; Theelen, Thomas; Goossens, Jeroen

    2017-12-01

    The useful-field-of-view (UFOV) test measures the amount of information someone can extract from a visual scene in one glance. Its scores show relatively strong relationships with everyday activities. The UFOV test consists of three computer tests, suggested to measure processing speed and central vision, divided attention, and selective attention. However, other functions seem to be involved as well. In order to investigate the contribution of these suggested and other perceptual and cognitive functions, we performed a meta-analysis of 116 Pearson's correlation coefficients between UFOV scores and other test scores reported in 18 peer-reviewed articles. We divided these correlations into nine domains: attention, executive functioning, general cognition, memory, spatial ability, visual closure, contrast sensitivity, visual processing speed, and visual acuity. A multivariate mixed-effects model analysis revealed that each domain correlated significantly with each of the UFOV subtest scores. These correlations were stronger for Subtests 2 and 3 than for Subtest 1. Furthermore, some domains were more strongly correlated to the UFOV than others across subtests. We did not find interaction effects between subtest and domain, indicating that none of the UFOV subtests is more selectively sensitive to a particular domain than the others. Thus, none of the three UFOV subtests seem to measure one clear construct. Instead, a range of visual and cognitive functions is involved. Perhaps this is the reason for the UFOV's high ecological validity, as it involves many functions at once, making it harder to compensate if one of them fails.

  20. Predicting Motor Vehicle Collisions in a Driving Simulator in Young Adults Using the Useful Field of View Assessment.

    Science.gov (United States)

    McManus, Benjamin; Cox, Molly K; Vance, David E; Stavrinos, Despina

    2015-01-01

    Being involved in motor vehicle collisions is the leading cause of death in 1- to 34-year-olds, and risk is particularly high in young adults. The Useful Field of View (UFOV) task, a cognitive measure of processing speed, divided attention, and selective attention, has been shown to be predictive of motor vehicle collisions in older adults, but its use as a predictor of driving performance in a young adult population has not been investigated. The present study examined whether UFOV was a predictive measure of motor vehicle collisions in a driving simulator in a young adult population. The 3-subtest version of UFOV (lower scores measured in milliseconds indicate better performance) was administered to 60 college students. Participants also completed an 11-mile simulated drive to provide driving performance metrics. Findings suggested that subtests 1 and 2 suffered from a ceiling effect. UFOV subtest 3 significantly predicted collisions in the simulated drive. Each 30 ms slower on the subtest was associated with nearly a 10% increase in the risk of a simulated collision. Post hoc analyses revealed a small partially mediating effect of subtest 3 on the relationship between driving experience and collisions. The selective attention component of UFOV subtest 3 may be a predictive measure of crash involvement in a young adult population. Improvements in selective attention may be the underlying mechanism in how driving experience improves driving performance.

  1. Evaluation of image quality with different field of view in CT scan of the body in children

    International Nuclear Information System (INIS)

    Gao Dechun; Wu Tai; Mao Dingli; Weng Zhigao

    2005-01-01

    Objective: To evaluate the relationship between field of view (FOV) and quality of CT images. Methods: Scanning of the phantoms of spatial resolution and density resolution was performed with FOVs of 25 cm x 25 cm, 35 cm x 35 cm, and 42 cm x 42 cm, respectively, and the spatial resolution and density resolution of CT images with different FOVs were measured. 20 patients underwent CT scanning using 25 cm x 25 cm and 35 cm x 35 cm FOVs, respectively. The images were evaluated by 3 qualified CT doctors by using a double-blind reading. Results: As FOVs changed, the spatial resolution and density resolution were different. The best spatial resolution and density resolution were obtained on 25 cm x 25 cm FOV images. The best spatial resolution could distinguish four 0.6 mm-diameter eyelets, and the best density resolution could distinguish five 2.5 mm-diameter eyelets. The CT images with 25 cm x 25 cm FOV were obviously better than those with 35 cm x 35 cm FOV (P<0.05). Conclusion: On the range of conventional FOV of CT, the spatial resolution and density resolution of CT images are the best when 25 cm x 25 cm FOV is used. (authors)

  2. Intraoperative Scintigraphy Using a Large Field-of-View Portable Gamma Camera for Primary Hyperparathyroidism: Initial Experience

    Directory of Open Access Journals (Sweden)

    Nathan C. Hall

    2015-01-01

    Full Text Available Background. We investigated a novel technique, intraoperative 99 mTc-Sestamibi (MIBI imaging (neck and excised specimen (ES, using a large field-of-view portable gamma camera (LFOVGC, for expediting confirmation of MIBI-avid parathyroid adenoma removal. Methods. Twenty patients with MIBI-avid parathyroid adenomas were preoperatively administered MIBI and intraoperatively imaged prior to incision (neck and immediately following resection (neck and/or ES. Preoperative and intraoperative serum parathyroid hormone monitoring (IOPTH and pathology (path were also performed. Results. MIBI neck activity was absent and specimen activity was present in 13/20 with imaging after initial ES removal. In the remaining 7/20 cases, residual neck activity and/or absent ES activity prompted excision of additional tissue, ultimately leading to complete hyperfunctioning tissue excision. Postexcision LFOVGC ES imaging confirmed parathyroid adenoma resection 100% when postresection imaging qualitatively had activity (ES and/or no activity (neck. The mean ± SEM time saving using intraoperative LFOVGC data to confirm resection versus first IOPTH or path result would have been 22.0 ± 2 minutes (specimen imaging and 26.0 ± 3 minutes (neck imaging. Conclusion. Utilization of a novel real-time intraoperative LFOVGC imaging approach can provide confirmation of MIBI-avid parathyroid adenoma removal appreciably faster than IOPTH and/or path and may provide a valuable adjunct to parathyroid surgery.

  3. Cumulative meta-analysis of the relationship between useful field of view and driving performance in older adults: current and future implications.

    Science.gov (United States)

    Clay, Olivio J; Wadley, Virginia G; Edwards, Jerri D; Roth, David L; Roenker, Daniel L; Ball, Karlene K

    2005-08-01

    Driving is a complex behavior that requires the utilization of a wide range of individual abilities. Identifying assessments that not only capture individual differences, but also are related to older adults' driving performance would be beneficial. This investigation examines the relationship between the Useful Field of View (UFOV) assessment and objective measures of retrospective or concurrent driving performance, including state-recorded accidents, on-road driving, and driving simulator performance. The PubMed and PsycINFO databases were searched to retrieve eight studies that reported bivariate relationships between UFOV and these objective driving measures. Cumulative meta-analysis techniques were used to combine the effect sizes in an attempt to determine whether the strength of the relationship was stable across studies and to assess whether a sufficient number of studies have been conducted to validate the relationship between UFOV and driving performance. A within-group homogeneity of effect sizes test revealed that the samples could be thought of as being drawn from the same population, Q [7] = 11.29, p (one-tailed) = 0.13. Therefore, the effect sizes of eight studies were combined for the present cumulative meta-analysis. The weighted mean effect size across the studies revealed a large effect (Cohen's d = 0.945), with poorer UFOV performance associated with negative driving outcomes. This relationship was robust across multiple indices of driving performance and several research laboratories. This convergence of evidence across numerous studies using different methodologies confirms the importance of the UFOV assessment as a valid and reliable index of driving performance and safety. Recent prospective studies have confirmed a relationship between UFOV performance and future crashes, further supporting the use of this instrument as a potential screening measure for at-risk older drivers.

  4. Michelson wide-field stellar interferometry

    NARCIS (Netherlands)

    Montilla, I.

    2004-01-01

    The main goal of this thesis is to develop a system to permit wide field operation of Michelson Interferometers. A wide field of view is very important in applications such as the observation of extended or multiple objects, the fringe acquisition and/ or tracking on a nearby unresolved object, and

  5. SU-G-TeP2-09: Evaluation of the MaxFOV Extended Field of View (EFOV) Reconstruction Algorithm On a GE RT590 CT Scanner

    International Nuclear Information System (INIS)

    Grzetic, S; Weldon, M; Noa, K; Gupta, N

    2016-01-01

    Purpose: This study compares the newly released MaxFOV Revision 1 EFOV reconstruction algorithm for GE RT590 to the older WideView EFOV algorithm. Two radiotherapy overlays from Q-fix and Diacor, are included in our analysis. Hounsfield Units (HU) generated with the WideView algorithm varied in the extended field (beyond 50cm) and the scanned object’s border varied from slice to slice. A validation of HU consistency between the two reconstruction algorithms is performed. Methods: A CatPhan 504 and CIRS062 Electron Density Phantom were scanned on a GE RT590 CT-Simulator. The phantoms were positioned in multiple locations within the scan field of view so some of the density plugs were outside the 50cm reconstruction circle. Images were reconstructed using both the WideView and MaxFOV algorithms. The HU for each scan were characterized both in average over a volume and in profile. Results: HU values are consistent between the two algorithms. Low-density material will have a slight increase in HU value and high-density material will have a slight decrease in HU value as the distance from the sweet spot increases. Border inconsistencies and shading artifacts are still present with the MaxFOV reconstruction on the Q-fix overlay but not the Diacor overlay (It should be noted that the Q-fix overlay is not currently GE-certified). HU values for water outside the 50cm FOV are within 40HU of reconstructions at the sweet spot of the scanner. CatPhan HU profiles show improvement with the MaxFOV algorithm as it approaches the scanner edge. Conclusion: The new MaxFOV algorithm improves the contour border for objects outside of the standard FOV when using a GE-approved tabletop. Air cavities outside of the standard FOV create inconsistent object borders. HU consistency is within GE specifications and the accuracy of the phantom edge improves. Further adjustments to the algorithm are being investigated by GE.

  6. Interior tomography in microscopic CT with image reconstruction constrained by full field of view scan at low spatial resolution

    Science.gov (United States)

    Luo, Shouhua; Shen, Tao; Sun, Yi; Li, Jing; Li, Guang; Tang, Xiangyang

    2018-04-01

    In high resolution (microscopic) CT applications, the scan field of view should cover the entire specimen or sample to allow complete data acquisition and image reconstruction. However, truncation may occur in projection data and results in artifacts in reconstructed images. In this study, we propose a low resolution image constrained reconstruction algorithm (LRICR) for interior tomography in microscopic CT at high resolution. In general, the multi-resolution acquisition based methods can be employed to solve the data truncation problem if the project data acquired at low resolution are utilized to fill up the truncated projection data acquired at high resolution. However, most existing methods place quite strict restrictions on the data acquisition geometry, which greatly limits their utility in practice. In the proposed LRICR algorithm, full and partial data acquisition (scan) at low and high resolutions, respectively, are carried out. Using the image reconstructed from sparse projection data acquired at low resolution as the prior, a microscopic image at high resolution is reconstructed from the truncated projection data acquired at high resolution. Two synthesized digital phantoms, a raw bamboo culm and a specimen of mouse femur, were utilized to evaluate and verify performance of the proposed LRICR algorithm. Compared with the conventional TV minimization based algorithm and the multi-resolution scout-reconstruction algorithm, the proposed LRICR algorithm shows significant improvement in reduction of the artifacts caused by data truncation, providing a practical solution for high quality and reliable interior tomography in microscopic CT applications. The proposed LRICR algorithm outperforms the multi-resolution scout-reconstruction method and the TV minimization based reconstruction for interior tomography in microscopic CT.

  7. Impacts of field of view configuration of Cross-track Infrared Sounder on clear-sky observations.

    Science.gov (United States)

    Wang, Likun; Chen, Yong; Han, Yong

    2016-09-01

    Hyperspectral infrared radiance measurements from satellite sensors contain valuable information on atmospheric temperature and humidity profiles and greenhouse gases, and therefore are directly assimilated into numerical weather prediction (NWP) models as inputs for weather forecasting. However, data assimilations in current operational NWP models still mainly rely on cloud-free observations due to the challenge of simulating cloud-contaminated radiances when using hyperspectral radiances. The limited spatial coverage of the 3×3 field of views (FOVs) in one field of regard (FOR) (i.e., spatial gap among FOVs) as well as relatively large footprint size (14 km) in current Cross-track Infrared Sounder (CrIS) instruments limits the amount of clear-sky observations. This study explores the potential impacts of future CrIS FOV configuration (including FOV size and spatial coverage) on the amount of clear-sky observations by simulation experiments. The radiance measurements and cloud mask products (VCM) from the Visible Infrared Imager Radiometer Suite (VIIRS) are used to simulate CrIS clear-sky observation under different FOV configurations. The results indicate that, given the same FOV coverage (e.g., 3×3), the percentage of clear-sky FOVs and the percentage of clear-sky FORs (that contain at least one clear-sky FOV) both increase as the FOV size decreases. In particular, if the CrIS FOV size were reduced from 14 km to 7 km, the percentage of clear-sky FOVs increases from 9.02% to 13.51% and the percentage of clear-sky FORs increases from 18.24% to 27.51%. Given the same FOV size but with increasing FOV coverage in each FOR, the clear-sky FOV observations increases proportionally with the increasing sampling FOVs. Both reducing FOV size and increasing FOV coverage can result in more clear-sky FORs, which benefit data utilization of NWP data assimilation.

  8. Multi-criteria decision analysis to select the optimum position and proper field of view of a photosensor

    International Nuclear Information System (INIS)

    Doulos, L.; Tsangrassoulis, A.; Topalis, F.V.

    2014-01-01

    Highlights: • A new methodology for the determination of proper FOV and position of a photosensor is proposed. • Model takes into account illuminance ratio, energy savings and lighting adequacy. • A multiple criteria decision method (ELECTRE) is used to estimate best solution. • A number of simulations were performed in order to clarify the calculation procedure. • An experimental procedure was performed in order to verify the simulation procedure. - Abstract: The lack of knowledge concerning the commissioning of a daylight responsive system constitutes a serious impediment to their widespread use. Furthermore, installation details and tools regarding their photosensor position and field of view (FOV) are insufficient. This paper presents a decision making method capable to estimate the best position of a photosensor on the ceiling and its proper FOV based on multiple criteria analysis. The criteria used are (a) the correlation of the lighting levels between the working plane and the ceiling, (b) the corresponding energy savings and (c) the lighting adequacy which is defined as the percentage for occupied time with total illuminance exceeding design illuminance (i.e 500 lux EN 12464-1, 2011) and is strongly affected by the control algorithm. A number of simulations with variable FOV and position of photosensors were performed in order to clarify the calculation procedure of the proposed methodology. Three different typical room geometries have been used with variable window sizes and orientation. Furthermore a prototype photosensor with variable FOV through the use of a telescopic cylinder was constructed and placed in a scale room (1:10) in order to verify the results of simulations. The verification was based on a set of experimental procedures concerning measurements of the spatial response of the prototype photosensor (for various FOVs) and measurements of ceiling/workplane illuminance inside the scaled room for various combinations of position and

  9. Evaluation of subjective image quality in relation to diagnostic task for cone beam computed tomography with different fields of view.

    Science.gov (United States)

    Lofthag-Hansen, Sara; Thilander-Klang, Anne; Gröndahl, Kerstin

    2011-11-01

    To evaluate subjective image quality for two diagnostic tasks, periapical diagnosis and implant planning, for cone beam computed tomography (CBCT) using different exposure parameters and fields of view (FOVs). Examinations were performed in posterior part of the jaws on a skull phantom with 3D Accuitomo (FOV 3 cm×4 cm) and 3D Accuitomo FPD (FOVs 4 cm×4 cm and 6 cm×6 cm). All combinations of 60, 65, 70, 75, 80 kV and 2, 4, 6, 8, 10 mA with a rotation of 180° and 360° were used. Dose-area product (DAP) value was determined for each combination. The images were presented, displaying the object in axial, cross-sectional and sagittal views, without scanning data in a random order for each FOV and jaw. Seven observers assessed image quality on a six-point rating scale. Intra-observer agreement was good (κw=0.76) and inter-observer agreement moderate (κw=0.52). Stepwise logistic regression showed kV, mA and diagnostic task to be the most important variables. Periapical diagnosis, regardless jaw, required higher exposure parameters compared to implant planning. Implant planning in the lower jaw required higher exposure parameters compared to upper jaw. Overall ranking of FOVs gave 4 cm×4 cm, 6 cm×6 cm followed by 3 cm×4 cm. This study has shown that exposure parameters should be adjusted according to diagnostic task. For this particular CBCT brand a rotation of 180° gave good subjective image quality, hence a substantial dose reduction can be achieved without loss of diagnostic information. Copyright © 2010 Elsevier Ireland Ltd. All rights reserved.

  10. Effect of stars in the field of view of the VHE gamma-ray atmospheric Cherenkov telescope

    International Nuclear Information System (INIS)

    Badran, H.M.

    2004-01-01

    Very high energy gamma-ray astronomy in the energy range above 100 GeV has made dramatic progress through the development of imaging atmospheric Cherenkov telescopes (lACTs). The technique has been pivotal in the establishing the existence of a number of discrete gamma-ray sources. Normally due to the presence of stars in the field of view (FOV), a number of photomultiplier tubes (pmts) in the camera has to be turned off. This may have the effect of distorting some images that happens to be in that part of the camera. This may in turn affect the gamma-ray sensitivity of the telescope. The present study aims to shade some light on this possible effect. Experimental data on the extragalactic gamma-ray source Mrk 421 measured using the 10-m Whipple IACT were used for this purpose because of its relative dark FOV compared with other sources; e.g. the Crab nebula. To simulate the presence of star(s) in the FOV, the analysis program selects randomly a number of clusters of pmts to be turned off in the software. The pmts in each cluster have to be adjacent to each other (neighbors) and the selected clusters have to be separated from each other. The significance of the detected signal and the gamma-ray rate were then determined and compared with the original results. Clusters of 2, 3 and 4 pmts were used. The number of clusters was increased up to 12 clusters at various distances from the center of the FOV

  11. Evaluation of subjective image quality in relation to diagnostic task for cone beam computed tomography with different fields of view

    International Nuclear Information System (INIS)

    Lofthag-Hansen, Sara; Thilander-Klang, Anne; Groendahl, Kerstin

    2011-01-01

    Aims: To evaluate subjective image quality for two diagnostic tasks, periapical diagnosis and implant planning, for cone beam computed tomography (CBCT) using different exposure parameters and fields of view (FOVs). Materials and methods: Examinations were performed in posterior part of the jaws on a skull phantom with 3D Accuitomo (FOV 3 cm x 4 cm) and 3D Accuitomo FPD (FOVs 4 cm x 4 cm and 6 cm x 6 cm). All combinations of 60, 65, 70, 75, 80 kV and 2, 4, 6, 8, 10 mA with a rotation of 180 o and 360 o were used. Dose-area product (DAP) value was determined for each combination. The images were presented, displaying the object in axial, cross-sectional and sagittal views, without scanning data in a random order for each FOV and jaw. Seven observers assessed image quality on a six-point rating scale. Results: Intra-observer agreement was good (κ w = 0.76) and inter-observer agreement moderate (κ w = 0.52). Stepwise logistic regression showed kV, mA and diagnostic task to be the most important variables. Periapical diagnosis, regardless jaw, required higher exposure parameters compared to implant planning. Implant planning in the lower jaw required higher exposure parameters compared to upper jaw. Overall ranking of FOVs gave 4 cm x 4 cm, 6 cm x 6 cm followed by 3 cm x 4 cm. Conclusions: This study has shown that exposure parameters should be adjusted according to diagnostic task. For this particular CBCT brand a rotation of 180 o gave good subjective image quality, hence a substantial dose reduction can be achieved without loss of diagnostic information.

  12. Quantitative investigation of a novel small field of view hybrid gamma camera (HGC) capability for sentinel lymph node detection

    Science.gov (United States)

    Lees, John E; Bugby, Sarah L; Jambi, Layal K; Perkins, Alan C

    2016-01-01

    Objective: The hybrid gamma camera (HGC) has been developed to enhance the localization of radiopharmaceutical uptake in targeted tissues during surgical procedures such as sentinel lymph node (SLN) biopsy. To assess the capability of the HGC, a lymph node contrast (LNC) phantom was constructed to simulate medical scenarios of varying radioactivity concentrations and SLN size. Methods: The phantom was constructed using two clear acrylic glass plates. The SLNs were simulated by circular wells of diameters ranging from 10 to 2.5 mm (16 wells in total) in 1 plate. The second plate contains four larger rectangular wells to simulate tissue background activity surrounding the SLNs. The activity used to simulate each SLN ranged between 4 and 0.025 MBq. The activity concentration ratio between the background and the activity injected in the SLNs was 1 : 10. The LNC phantom was placed at different depths of scattering material ranging between 5 and 40 mm. The collimator-to-source distance was 120 mm. Image acquisition times ranged from 60 to 240 s. Results: Contrast-to-noise ratio analysis and full-width-at-half-maximum (FWHM) measurements of the simulated SLNs were carried out for the images obtained. Over the range of activities used, the HGC detected between 87.5 and 100% of the SLNs through 20 mm of scattering material and 75–93.75% of the SLNs through 40 mm of scattering material. The FWHM of the detected SLNs ranged between 11.93 and 14.70 mm. Conclusion: The HGC is capable of detecting low accumulation of activity in small SLNs, indicating its usefulness as an intraoperative imaging system during surgical SLN procedures. Advances in knowledge: This study investigates the capability of a novel small-field-of-view (SFOV) HGC to detect low activity uptake in small SLNs. The phantom and procedure described are inexpensive and could be easily replicated and applied to any SFOV camera, to provide a comparison between systems with clinically relevant

  13. Field of view extension and truncation correction for MR-based human attenuation correction in simultaneous MR/PET imaging

    International Nuclear Information System (INIS)

    Blumhagen, Jan O.; Ladebeck, Ralf; Fenchel, Matthias; Braun, Harald; Quick, Harald H.; Faul, David; Scheffler, Klaus

    2014-01-01

    Purpose: In quantitative PET imaging, it is critical to accurately measure and compensate for the attenuation of the photons absorbed in the tissue. While in PET/CT the linear attenuation coefficients can be easily determined from a low-dose CT-based transmission scan, in whole-body MR/PET the computation of the linear attenuation coefficients is based on the MR data. However, a constraint of the MR-based attenuation correction (AC) is the MR-inherent field-of-view (FoV) limitation due to static magnetic field (B 0 ) inhomogeneities and gradient nonlinearities. Therefore, the MR-based human AC map may be truncated or geometrically distorted toward the edges of the FoV and, consequently, the PET reconstruction with MR-based AC may be biased. This is especially of impact laterally where the patient arms rest beside the body and are not fully considered. Methods: A method is proposed to extend the MR FoV by determining an optimal readout gradient field which locally compensates B 0 inhomogeneities and gradient nonlinearities. This technique was used to reduce truncation in AC maps of 12 patients, and the impact on the PET quantification was analyzed and compared to truncated data without applying the FoV extension and additionally to an established approach of PET-based FoV extension. Results: The truncation artifacts in the MR-based AC maps were successfully reduced in all patients, and the mean body volume was thereby increased by 5.4%. In some cases large patient-dependent changes in SUV of up to 30% were observed in individual lesions when compared to the standard truncated attenuation map. Conclusions: The proposed technique successfully extends the MR FoV in MR-based attenuation correction and shows an improvement of PET quantification in whole-body MR/PET hybrid imaging. In comparison to the PET-based completion of the truncated body contour, the proposed method is also applicable to specialized PET tracers with little uptake in the arms and might reduce the

  14. Development and validation of a novel large field of view phantom and a software module for the quality assurance of geometric distortion in magnetic resonance imaging.

    Science.gov (United States)

    Torfeh, Tarraf; Hammoud, Rabih; McGarry, Maeve; Al-Hammadi, Noora; Perkins, Gregory

    2015-09-01

    To develop and validate a large field of view phantom and quality assurance software tool for the assessment and characterization of geometric distortion in MRI scanners commissioned for radiation therapy planning. A purpose built phantom was developed consisting of 357 rods (6mm in diameter) of polymethyl-methacrylat separated by 20mm intervals, providing a three dimensional array of control points at known spatial locations covering a large field of view up to a diameter of 420mm. An in-house software module was developed to allow automatic geometric distortion assessment. This software module was validated against a virtual dataset of the phantom that reproduced the exact geometry of the physical phantom, but with known translational and rotational displacements and warping. For validation experiments, clinical MRI sequences were acquired with and without the application of a commercial 3D distortion correction algorithm (Gradwarp™). The software module was used to characterize and assess system-related geometric distortion in the sequences relative to a benchmark CT dataset, and the efficacy of the vendor geometric distortion correction algorithms (GDC) was also assessed. Results issued from the validation of the software against virtual images demonstrate the algorithm's ability to accurately calculate geometric distortion with sub-pixel precision by the extraction of rods and quantization of displacements. Geometric distortion was assessed for the typical sequences used in radiotherapy applications and over a clinically relevant 420mm field of view (FOV). As expected and towards the edges of the field of view (FOV), distortion increased with increasing FOV. For all assessed sequences, the vendor GDC was able to reduce the mean distortion to below 1mm over a field of view of 5, 10, 15 and 20cm radius respectively. Results issued from the application of the developed phantoms and algorithms demonstrate a high level of precision. The results indicate that this

  15. Lens Systems Incorporating A Zero Power Corrector Principle Of The Design And Its Application In Large Aperture, Moderate Field Of View Optical Systems

    Science.gov (United States)

    Klee, H. W.; McDowell, M. W.

    1986-02-01

    A new lens design concept, based on the use of a zero (or near zero) power corrector, will be described. The logical development of the design, based on the work of Schmidt', Houghton' and others will be discussed and examples will be given of moderate field of view lenses with apertures ranging from f/0.35 to f/2. It will also be shown that the lens configuration is relatively insensitive to the aperture stop location and that for less demanding applications only very basic optical glass types need be used.

  16. Study of two novel large-field-of-view image intensifiers versus conventional chest radiography with use of FROC methods and simulated pulmonary nodules

    International Nuclear Information System (INIS)

    Winter, L.H.L.; Chakraborty, D.P.; Van Waes, P.F.G.M.; Puylaert, C.B.A.J.

    1989-01-01

    Two novel large-field-of-view image intensifier (LFOV 1.1) tubes have been introduced whose image area makes them suitable for chest imaging. Both modalities present a 100-mm hard-copy image to the radiologist. A pulmonary nodule performance experiment was done to compare the diagnostic accuracy of these tubes with conventional full-size chest images. The data were analyzed with the maximum-likelihood FROCFIT program. The relative ranking in terms of decreasing A1 values was TLX, Siemens 43-cm mode, conventional radiography, and Siemens 57-cm mode

  17. Combined large field-of-view MRA and time-resolved MRA of the lower extremities: Impact of acquisition order on image quality

    International Nuclear Information System (INIS)

    Riffel, Philipp; Haneder, Stefan; Attenberger, Ulrike I.; Brade, Joachim; Schoenberg, Stefan O.; Michaely, Henrik J.

    2012-01-01

    Purpose: Different approaches exist for hybrid MRA of the calf station. So far, the order of the acquisition of the focused calf MRA and the large field-of-view MRA has not been scientifically evaluated. Therefore the aim of this study was to evaluate if the quality of the combined large field-of-view MRA (CTM MR angiography) and time-resolved MRA with stochastic interleaved trajectories (TWIST MRA) depends on the order of acquisition of the two contrast-enhanced studies. Methods: In this retrospective study, 40 consecutive patients (mean age 68.1 ± 8.7 years, 29 male/11 female) who had undergone an MR angiographic protocol that consisted of CTM-MRA (TR/TE, 2.4/1.0 ms; 21° flip angle; isotropic resolution 1.2 mm; gadolinium dose, 0.07 mmol/kg) and TWIST-MRA (TR/TE 2.8/1.1; 20° flip angle; isotropic resolution 1.1 mm; temporal resolution 5.5 s, gadolinium dose, 0.03 mmol/kg), were included. In the first group (group 1) TWIST-MRA of the calf station was performed 1–2 min after CTM-MRA. In the second group (group 2) CTM-MRA was performed 1–2 min after TWIST-MRA of the calf station. The image quality of CTM-MRA and TWIST-MRA were evaluated by 2 two independent radiologists in consensus according to a 4-point Likert-like rating scale assessing overall image quality on a segmental basis. Venous overlay was assessed per examination. Results: In the CTM-MRA, 1360 segments were included in the assessment of image quality. CTM-MRA was diagnostic in 95% (1289/1360) of segments. There was a significant difference (p < 0.0001) between both groups with regard to the number of segments rated as excellent and moderate. The image quality was rated as excellent in group 1 in 80% (514/640 segments) and in group 2 in 67% (432/649), respectively (p < 0.0001). In contrast, the image quality was rated as moderate in the first group in 5% (33/640) and in the second group in 19% (121/649) respectively (p < 0.0001). The venous overlay was disturbing in 10% in group 1 and 20% in group

  18. The effect of metal artifacts on the identification of vertical root fractures using different fields of view in cone-beam computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Moudi, Ehsan; Haghanifar, Sina; Madani, Zahrasadat; Bijani, Ali; Nabavi, Zeynab Sadat [Babol University of Medical Science, Babol (Iran, Islamic Republic of)

    2015-09-15

    The aim of this study was to investigate the effects of metal artifacts on the accurate diagnosis of root fractures using cone-beam computed tomography (CBCT) images with large and small/limited fields of view (FOVs). Forty extracted molar and premolar teeth were collected. Access canals were made in all teeth using a rotary system. In half of the teeth, fractures were created by the application of mild pressure with a hammer. The teeth were then randomly put into a wax rim on an acryl base designed in the shape of a mandible. CBCT scans were obtained using a Newtom 5G system with FOVs of 18 cm×16 cm and 6 cm×6 cm. A metal pin was then placed into each tooth, and CBCT imaging was again performed using the same fields of view. All scans were evaluated by two oral and maxillofacial radiologists. The specificity, sensitivity, positive predictive value, negative predictive value, and likelihood ratios (positive and negative) were calculated. The maximum levels of sensitivity and specificity (100% and 100%, respectively) were observed in small volume CBCT scans of teeth without pins. The highest negative predictive value was found in the small-volume group without pins, whereas the positive predictive value was 100% in all groups except the large-volume group with pins.

  19. The impact of instrument field of view on measurements of cloudy-sky spectral radiances from space: application to IRIS and IMG

    Energy Technology Data Exchange (ETDEWEB)

    Brindley, H.E. E-mail: h.brindley@ic.ac.uk; Harries, J.E

    2003-05-15

    Spatially resolved images from the MODerate Resolution Imaging Spectrometer (MODIS) instrument are used to investigate the impact of a change in spatial field of view, from that typical of the Nimbus 4 Infrared Interferometer Spectrometer (IRIS) to that of the Interferometric Monitor for Greenhouse Gases (IMG), upon the spectral outgoing longwave radiation (OLR). Considering all-sky conditions it is found that for a typical tropical scene, approximately 150 paired measurements are required to obtain agreement to within {+-}2 K in the average brightness temperature (T{sub B}), in the most transparent window channels. At mid-latitudes, the reduced scene variability means that fewer observations are required to meet the same criterion. For clear- and cloudy-sky separation a simple threshold technique based on the window T{sub B} and underlying sea-surface temperature tends to result in a systematic underestimate of the average cloudy T{sub B} by the larger field of view. A better estimate can be obtained by applying a double threshold to discriminate against the most mixed scenes.

  20. Michelson wide-field stellar interferometry : Principles and experimental verification

    NARCIS (Netherlands)

    Montilla, I.; Pereira, S.F.; Braat, J.J.M.

    2005-01-01

    A new interferometric technique for Michelson wide-field interferometry is presented that consists of a Michelson pupil-plane combination scheme in which a wide field of view can be achieved in one shot. This technique uses a stair-shaped mirror in the intermediate image plane of each telescope in

  1. User's guide: Nimbus-7 Earth radiation budget narrow-field-of-view products. Scene radiance tape products, sorting into angular bins products, and maximum likelihood cloud estimation products

    Science.gov (United States)

    Kyle, H. Lee; Hucek, Richard R.; Groveman, Brian; Frey, Richard

    1990-01-01

    The archived Earth radiation budget (ERB) products produced from the Nimbus-7 ERB narrow field-of-view scanner are described. The principal products are broadband outgoing longwave radiation (4.5 to 50 microns), reflected solar radiation (0.2 to 4.8 microns), and the net radiation. Daily and monthly averages are presented on a fixed global equal area (500 sq km), grid for the period May 1979 to May 1980. Two independent algorithms are used to estimate the outgoing fluxes from the observed radiances. The algorithms are described and the results compared. The products are divided into three subsets: the Scene Radiance Tapes (SRT) contain the calibrated radiances; the Sorting into Angular Bins (SAB) tape contains the SAB produced shortwave, longwave, and net radiation products; and the Maximum Likelihood Cloud Estimation (MLCE) tapes contain the MLCE products. The tape formats are described in detail.

  2. Genetic modulation of training and transfer in older adults:BDNF Val66Met polymorphism is associated with wider useful field of view

    Directory of Open Access Journals (Sweden)

    Lorenza S Colzato

    2011-09-01

    Full Text Available Western society has an increasing proportion of older adults. Increasing age is associated with a general decrease in the control over task-relevant mental processes. In the present study we investigated the possibility that successful transfer of game-based cognitive improvements to untrained tasks in elderly people is modulated by preexisting neuro-developmental factors as genetic variability related to levels of the brain-derived neurotrophic factor (BDNF, an important neuromodulator underlying cognitive processes. We trained participants, genotyped for the BDNF Val66Met polymorphism, on cognitive tasks developed to improve dynamic attention. Pre-training (baseline and post-training measures of attentional processes (divided and selective attention were acquired by means of the Useful Field of View (UFOV task. As expected, Val/Val homozygous individuals showed larger beneficial transfer effects than Met/-carriers. Our findings support the idea that genetic predisposition modulates transfer effects.

  3. Development of a Large Field-of-View PIV System for Rotorcraft Testing in the 14- x 22-Foot Subsonic Tunnel

    Science.gov (United States)

    Jenkins, Luther N.; Yao, Chung-Sheng; Bartram, Scott M.; Harris, Jerome; Allan, Brian; Wong, Oliver; Mace, W. Derry

    2009-01-01

    A Large Field-of-View Particle Image Velocimetry (LFPIV) system has been developed for rotor wake diagnostics in the 14-by 22-Foot Subsonic Tunnel. The system has been used to measure three components of velocity in a plane as large as 1.524 meters by 0.914 meters in both forward flight and hover tests. Overall, the system performance has exceeded design expectations in terms of accuracy and efficiency. Measurements synchronized with the rotor position during forward flight and hover tests have shown that the system is able to capture the complex interaction of the body and rotor wakes as well as basic details of the blade tip vortex at several wake ages. Measurements obtained with traditional techniques such as multi-hole pressure probes, Laser Doppler Velocimetry (LDV), and 2D Particle Image Velocimetry (PIV) show good agreement with LFPIV measurements.

  4. Breast-specific gamma-imaging: molecular imaging of the breast using 99mTc-sestamibi and a small-field-of-view gamma-camera.

    Science.gov (United States)

    Jones, Elizabeth A; Phan, Trinh D; Blanchard, Deborah A; Miley, Abbe

    2009-12-01

    Breast-specific gamma-imaging (BSGI), also known as molecular breast imaging, is breast scintigraphy using a small-field-of-view gamma-camera and (99m)Tc-sestamibi. There are many different types of breast cancer, and many have characteristics making them challenging to detect by mammography and ultrasound. BSGI is a cost-effective, highly sensitive and specific technique that complements other imaging modalities currently being used to identify malignant lesions in the breast. Using the current Society of Nuclear Medicine guidelines for breast scintigraphy, Legacy Good Samaritan Hospital began conducting BSGI, breast scintigraphy with a breast-optimized gamma-camera. In our experience, optimal imaging has been conducted in the Breast Center by a nuclear medicine technologist. In addition, the breast radiologists read the BSGI images in correlation with the mammograms, ultrasounds, and other imaging studies performed. By modifying the current Society of Nuclear Medicine protocol to adapt it to the practice of breast scintigraphy with these new systems and by providing image interpretation in conjunction with the other breast imaging studies, our center has found BSGI to be a valuable adjunctive procedure in the diagnosis of breast cancer. The development of a small-field-of-view gamma-camera, designed to optimize breast imaging, has resulted in improved detection capabilities, particularly for lesions less than 1 cm. Our experience with this procedure has proven to aid in the clinical work-up of many of our breast patients. After reading this article, the reader should understand the history of breast scintigraphy, the pharmaceutical used, patient preparation and positioning, imaging protocol guidelines, clinical indications, and the role of breast scintigraphy in breast cancer diagnosis.

  5. Incidental abdominopelvic findings on expanded field-of-view lumbar spinal MRI: frequency, clinical importance, and concordance in interpretation by neuroimaging and body imaging radiologists

    International Nuclear Information System (INIS)

    Maxwell, A.W.P.; Keating, D.P.; Nickerson, J.P.

    2015-01-01

    Aim: To characterize the frequency of identification, clinical importance, and concordance in interpretation of incidental abdominopelvic findings identified on routine lumbar spinal MRI using supplemental expanded field-of-view (FOV) coronal imaging. Materials and methods: All lumbar spinal MRI reports over a 12-month period were retrospectively reviewed for the presence of incidental abdominopelvic findings identified using expanded FOV coronal imaging. Medical records were used to identify those findings that received follow-up, which were then categorized according to final diagnosis and classified as “indeterminate,” “likely clinically unimportant,” and “likely clinically important”. All cases that received follow-up were blindly and independently re-reviewed by a neuroimaging radiologist and body-imaging radiologist, and reviewer performances were compared to assess for agreement with regard to lesion significance, need for follow-up, and other parameters. Results: In total, 2067 reports were reviewed: 687 (33.2%) featured one or more incidental abdominopelvic findings, and 102 (4.9%) findings received further evaluation. Of these, 11 (10.9%) were classified as “indeterminate,” 50 (49%) as “likely clinically unimportant,” and 41 (40.1%) were classified as “likely clinically important.” Excellent agreement was observed between the reviewing radiologists for all evaluated parameters. Conclusion: The addition of an expanded FOV coronal sequence to the standard lumbar spinal MRI protocol was associated with the identification of a large number of incidental abdominopelvic findings, the minority of which represent likely clinically important findings. Most incidental findings were confidently dismissed by a neuroimaging radiologist as likely clinically unimportant without utilization of additional clinical or radiographic resources. - Highlights: • Expanded field-of-view (FOV) MRI improves detection of important incidental findings.

  6. Wide-Field Imaging Using Nitrogen Vacancies

    Science.gov (United States)

    Englund, Dirk Robert (Inventor); Trusheim, Matthew Edwin (Inventor)

    2017-01-01

    Nitrogen vacancies in bulk diamonds and nanodiamonds can be used to sense temperature, pressure, electromagnetic fields, and pH. Unfortunately, conventional sensing techniques use gated detection and confocal imaging, limiting the measurement sensitivity and precluding wide-field imaging. Conversely, the present sensing techniques do not require gated detection or confocal imaging and can therefore be used to image temperature, pressure, electromagnetic fields, and pH over wide fields of view. In some cases, wide-field imaging supports spatial localization of the NVs to precisions at or below the diffraction limit. Moreover, the measurement range can extend over extremely wide dynamic range at very high sensitivity.

  7. Assessment of CT numbers in limited and medium field-of-view scans taken using Accuitomo 170 and Veraviewepocs 3De cone-beam computed tomography scanners

    Energy Technology Data Exchange (ETDEWEB)

    Oliveira, Matheus L. [Dept. of Oral Diagnosis, Piracicaba Dental School, State University of Campinas, Campinas (Brazil); Tosoni, Guilherme M. [Dept. of Oral Diagnosis and Surgery, Araraquara Dental School, Sao Paulo State University, Araraquara (Brazil); Lindsey, David H.; Mendoza, Kristopher; Tetradis, Sotirios; Mallya, Sanjay M. [Section of Oral and Maxillofacial Radiology, School of Dentistry, University of California, Los Angeles (United States)

    2014-12-15

    To assess the influence of anatomic location on the relationship between computed tomography (CT) number and X-ray attenuation in limited and medium field-of-view (FOV) scans. Tubes containing solutions with different concentrations of K2HPO4 were placed in the tooth sockets of a human head phantom. Cone-beam computed tomography (CBCT) scans were acquired, and CT numbers of the K{sub 2}HPO{sub 4} solutions were measured. The relationship between CT number and K{sub 2}HPO{sub 4} concentration was examined by linear regression analyses. Then, the variation in CT number according to anatomic location was examined. The relationship between K{sub 2}HPO{sub 4} concentration and CT number was strongly linear. The slopes of the linear regressions for the limited FOVs were almost 2-fold lower than those for the medium FOVs. The absolute CT number differed between imaging protocols and anatomic locations. There is a strong linear relationship between X-ray attenuation and CT number. The specific imaging protocol and anatomic location of the object strongly influence this relationship.

  8. Effect of field-of-view size on gray values derived from cone-beam computed tomography compared with the Hounsfield unit values from multidetector computed tomography scans.

    Science.gov (United States)

    Shokri, Abbas; Ramezani, Leila; Bidgoli, Mohsen; Akbarzadeh, Mahdi; Ghazikhanlu-Sani, Karim; Fallahi-Sichani, Hamed

    2018-03-01

    This study aimed to evaluate the effect of field-of-view (FOV) size on the gray values derived from conebeam computed tomography (CBCT) compared with the Hounsfield unit values from multidetector computed tomography (MDCT) scans as the gold standard. A radiographic phantom was designed with 4 acrylic cylinders. One cylinder was filled with distilled water, and the other 3 were filled with 3 types of bone substitute: namely, Nanobone, Cenobone, and Cerabone. The phantom was scanned with 2 CBCT systems using 2 different FOV sizes, and 1 MDCT system was used as the gold standard. The mean gray values (MGVs) of each cylinder were calculated in each imaging protocol. In both CBCT systems, significant differences were noted in the MGVs of all materials between the 2 FOV sizes ( P <.05) except for Cerabone in the Cranex3D system. Significant differences were found in the MGVs of each material compared with the others in both FOV sizes for each CBCT system. No significant difference was seen between the Cranex3D CBCT system and the MDCT system in the MGVs of bone substitutes on images obtained with a small FOV. The size of the FOV significantly changed the MGVs of all bone substitutes, except for Cerabone in the Cranex3D system. Both CBCT systems had the ability to distinguish the 3 types of bone substitutes based on a comparison of their MGVs. The Cranex3D CBCT system used with a small FOV had a significant correlation with MDCT results.

  9. MediSPECT: Single photon emission computed tomography system for small field of view small animal imaging based on a CdTe hybrid pixel detector

    International Nuclear Information System (INIS)

    Accorsi, R.; Autiero, M.; Celentano, L.

    2007-01-01

    We describe MediSPECT, a new scanner developed at University and INFN Napoli, for SPECT studies on small animals with a small field of view (FOV) and high spatial resolution. The CdTe pixel detector (a 256x256 matrix of 55 μm square pixels) operating in single photon counting for detection of gamma-rays with low and medium energy (e.g. 125 I, 27-35 keV, 99m Tc, 140 keV), is bump bonded to the Medipix2 readout chip. The FOV of the MediSPECT scanner with a coded aperture mask collimator ranges from 6.3 mm (system spatial resolution 110 μm at 27-35 keV) to 24.3 mm. With a 0.30 mm pinhole the FOV ranges from 2.4 to 29 mm (where the system spatial resolution is 1.0 mm at 27-35 keV and 2.0 mm at 140 keV). MediSPECT will be used for in vivo imaging of small organs or tissue structures in mouse, e.g., brain, thyroid, heart or tumor

  10. Influence of a small field-of-view size on the detection of coronary artery calcifications with MSCT: in vitro and in vivo study

    International Nuclear Information System (INIS)

    Mahnken, Andreas H.; Muehlenbruch, Georg; Das, Marco; Pohl, Saskia; Guenther, Rolf W.; Wildberger, Joachim E.; Koos, Ralf; Stanzel, Sven

    2006-01-01

    The purpose of this study is to asses the impact of small field-of-view (FOV) sizes on the detection of coronary artery calcifications using multislice-spiral computed tomography (MSCT). First, a static chest phantom containing calcium inserts was scanned 10 times using a standardized scan protocol. Secondly, 50 patients (28 male, 63.6±10.6 years) underwent cardiac MSCT using the same protocol. Images were reconstructed with three different FOV sizes (180 x 180, 220 x 220, 380 x 380 mm 2 ). Coronary calcium scoring and risk stratification were performed for each image series. In the phantom study, the Agatston score calculated with a FOV size of 180 x 180 mm 2 was 657.80±20.05. At a FOV of 220 x 220 mm 2 and 380 x 380 mm 2 , the corresponding values were 657.04±21.36 and 655.04±20.74, respectively. The corresponding values in the patient study were 541.65±869.87, 541.91±872.57 and 536.61±867.81. No statistically significant differences in the calcium score were found comparing different FOV sizes. Significantly more lesions (p=0.00149) were detected in the patient study. Comparing the different FOV sizes of 180 x 180 mm 2 and 220 x 220 mm 2 (380 x 380 mm 2 ), four (six) patients had to be assigned to different risk groups. The use of small FOV sizes resulted in an improved detection of coronary calcifications influencing the risk stratification for further cardiac events in MSCT coronary calcium scoring. (orig.)

  11. Spatially selective 2D RF inner field of view (iFOV diffusion kurtosis imaging (DKI of the pediatric spinal cord

    Directory of Open Access Journals (Sweden)

    Chris J. Conklin

    2016-01-01

    Full Text Available Magnetic resonance based diffusion imaging has been gaining more utility and clinical relevance over the past decade. Using conventional echo planar techniques, it is possible to acquire and characterize water diffusion within the central nervous system (CNS; namely in the form of Diffusion Weighted Imaging (DWI and Diffusion Tensor Imaging (DTI. While each modality provides valuable clinical information in terms of the presence of diffusion and its directionality, both techniques are limited to assuming an ideal Gaussian distribution for water displacement with no intermolecular interactions. This assumption neglects pathological processes that are not Gaussian therefore reducing the amount of potentially clinically relevant information. Additions to the Gaussian distribution measured by the excess kurtosis, or peakedness, of the probabilistic model provide a better understanding of the underlying cellular structure. The objective of this work is to provide mathematical and experimental evidence that Diffusion Kurtosis Imaging (DKI can offer additional information about the micromolecular environment of the pediatric spinal cord. This is accomplished by a more thorough characterization of the nature of random water displacement within the cord. A novel DKI imaging sequence based on a tilted 2D spatially selective radio frequency pulse providing reduced field of view (FOV imaging was developed, implemented, and optimized on a 3 Tesla MRI scanner, and tested on pediatric subjects (healthy subjects: 15; patients with spinal cord injury (SCI:5. Software was developed and validated for post processing of the DKI images and estimation of the tensor parameters. The results show statistically significant differences in mean kurtosis (p < 0.01 and radial kurtosis (p < 0.01 between healthy subjects and subjects with SCI. DKI provides incremental and novel information over conventional diffusion acquisitions when coupled with higher order estimation

  12. Effective radiation dose and eye lens dose in dental cone beam CT: effect of field of view and angle of rotation.

    Science.gov (United States)

    Pauwels, R; Zhang, G; Theodorakou, C; Walker, A; Bosmans, H; Jacobs, R; Bogaerts, R; Horner, K

    2014-10-01

    To quantify the effect of field of view (FOV) and angle of rotation on radiation dose in dental cone beam CT (CBCT) and to define a preliminary volume-dose model. Organ and effective doses were estimated using 148 thermoluminescent dosemeters placed in an anthropomorphic phantom. Dose measurements were undertaken on a 3D Accuitomo 170 dental CBCT unit (J. Morita, Kyoto, Japan) using six FOVs as well as full-rotation (360°) and half-rotation (180°) protocols. For the 360° rotation protocols, effective dose ranged between 54 µSv (4 × 4 cm, upper canine) and 303 µSv (17 × 12 cm, maxillofacial). An empirical relationship between FOV dimension and effective dose was derived. The use of a 180° rotation resulted in an average dose reduction of 45% compared with a 360° rotation. Eye lens doses ranged between 95 and 6861 µGy. Significant dose reduction can be achieved by reducing the FOV size, particularly the FOV height, of CBCT examinations to the actual region of interest. In some cases, a 180° rotation can be preferred, as it has the added value of reducing the scan time. Eye lens doses should be reduced by decreasing the height of the FOV rather than using inferior FOV positioning, as the latter would increase the effective dose considerably. The effect of the FOV and rotation angle on the effective dose in dental CBCT was quantified. The dominant effect of FOV height was demonstrated. A preliminary model has been proposed, which could be used to predict effective dose as a function of FOV size and position.

  13. Quantitative diffusion MRI using reduced field-of-view and multi-shot acquisition techniques: Validation in phantoms and prostate imaging.

    Science.gov (United States)

    Zhang, Yuxin; Holmes, James; Rabanillo, Iñaki; Guidon, Arnaud; Wells, Shane; Hernando, Diego

    2018-04-17

    To evaluate the reproducibility of quantitative diffusion measurements obtained with reduced Field of View (rFOV) and Multi-shot EPI (msEPI) acquisitions, using single-shot EPI (ssEPI) as a reference. Diffusion phantom experiments, and prostate diffusion-weighted imaging in healthy volunteers and patients with known or suspected prostate cancer were performed across the three different sequences. Quantitative diffusion measurements of apparent diffusion coefficient, and diffusion kurtosis parameters (healthy volunteers), were obtained and compared across diffusion sequences (rFOV, msEPI, and ssEPI). Other possible confounding factors like b-value combinations and acquisition parameters were also investigated. Both msEPI and rFOV have shown reproducible quantitative diffusion measurements relative to ssEPI; no significant difference in ADC was observed across pulse sequences in the standard diffusion phantom (p = 0.156), healthy volunteers (p ≥ 0.12) or patients (p ≥ 0.26). The ADC values within the non-cancerous central gland and peripheral zone of patients were 1.29 ± 0.17 × 10 -3  mm 2 /s and 1.74 ± 0.23 × 10 -3  mm 2 /s respectively. However, differences in quantitative diffusion parameters were observed across different number of averages for rFOV, and across b-value groups and diffusion models for all the three sequences. Both rFOV and msEPI have the potential to provide high image quality with reproducible quantitative diffusion measurements in prostate diffusion MRI. Copyright © 2018 Elsevier Inc. All rights reserved.

  14. Neural dynamics of object-based multifocal visual spatial attention and priming: object cueing, useful-field-of-view, and crowding.

    Science.gov (United States)

    Foley, Nicholas C; Grossberg, Stephen; Mingolla, Ennio

    2012-08-01

    How are spatial and object attention coordinated to achieve rapid object learning and recognition during eye movement search? How do prefrontal priming and parietal spatial mechanisms interact to determine the reaction time costs of intra-object attention shifts, inter-object attention shifts, and shifts between visible objects and covertly cued locations? What factors underlie individual differences in the timing and frequency of such attentional shifts? How do transient and sustained spatial attentional mechanisms work and interact? How can volition, mediated via the basal ganglia, influence the span of spatial attention? A neural model is developed of how spatial attention in the where cortical stream coordinates view-invariant object category learning in the what cortical stream under free viewing conditions. The model simulates psychological data about the dynamics of covert attention priming and switching requiring multifocal attention without eye movements. The model predicts how "attentional shrouds" are formed when surface representations in cortical area V4 resonate with spatial attention in posterior parietal cortex (PPC) and prefrontal cortex (PFC), while shrouds compete among themselves for dominance. Winning shrouds support invariant object category learning, and active surface-shroud resonances support conscious surface perception and recognition. Attentive competition between multiple objects and cues simulates reaction-time data from the two-object cueing paradigm. The relative strength of sustained surface-driven and fast-transient motion-driven spatial attention controls individual differences in reaction time for invalid cues. Competition between surface-driven attentional shrouds controls individual differences in detection rate of peripheral targets in useful-field-of-view tasks. The model proposes how the strength of competition can be mediated, though learning or momentary changes in volition, by the basal ganglia. A new explanation of

  15. MO-DE-207B-04: Impact of Reconstruction Field of View On Radiomics Features in Computed Tomography (CT) Using a Texture Phantom

    Energy Technology Data Exchange (ETDEWEB)

    Shafiq ul Hassan, M; Zhang, G; Oliver, J; Moros, E [H Lee Moffitt Cancer Center and Research Institute, Tampa, FL (United States); Department of Physics, University of South Florida (United States); Latifi, K; Hunt, D; Guzman, R; Balagurunathan, Y; Gillies, R [H Lee Moffitt Cancer Center and Research Institute, Tampa, FL (United States); Mackin, D; Court, L [UT MD Anderson Cancer Center, Houston, TX (United States)

    2016-06-15

    Purpose: To investigate the impact of reconstruction Field of View on Radiomics features in computed tomography (CT) using a texture phantom. Methods: A rectangular Credence Cartridge Radiomics (CCR) phantom, composed of 10 different cartridges, was scanned on four different CT scanners from two manufacturers. A pre-defined scanning protocol was adopted for consistency. The slice thickness and reconstruction interval of 1.5 mm was used on all scanners. The reconstruction FOV was varied to result a voxel size ranging from 0.38 to 0.98 mm. A spherical region of interest (ROI) was contoured on the shredded rubber cartridge from CCR phantom CT scans. Ninety three Radiomics features were extracted from ROI using an in-house program. These include 10 shape, 22 intensity, 26 GLCM, 11 GLZSM, 11 RLM, 5 NGTDM and 8 fractal dimensional features. To evaluate the Interscanner variability across three scanners, a coefficient of variation (COV) was calculated for each feature group. Each group was further classified according to the COV by calculating the percentage of features in each of the following categories: COV≤ 5%, between 5 and 10% and ≥ 10%. Results: Shape features were the most robust, as expected, because of the spherical contouring of ROI. Intensity features were the second most robust with 54.5 to 64% of features with COV < 5%. GLCM features ranged from 31 to 35% for the same category. RLM features were sensitive to specific scanner and 5% variability was 9 to 54%. Almost all GLZM and NGTDM features showed COV ≥10% among the scanners. The dependence of fractal dimensions features on FOV was not consistent across different scanners. Conclusion: We concluded that reconstruction FOV greatly influence Radiomics features. The GLZSM and NGTDM are highly sensitive to FOV. funded in part by Grant NIH/NCI R01CA190105-01.

  16. SU-F-J-23: Field-Of-View Expansion in Cone-Beam CT Reconstruction by Use of Prior Information

    Energy Technology Data Exchange (ETDEWEB)

    Haga, A; Magome, T; Nakano, M; Nakagawa, K [University of Tokyo Hospital, Tokyo (Japan); Kotoku, J [Teikyo University, Tokyo (Japan)

    2016-06-15

    Purpose: Cone-beam CT (CBCT) has become an integral part of online patient setup in an image-guided radiation therapy (IGRT). In addition, the utility of CBCT for dose calculation has actively been investigated. However, the limited size of field-of-view (FOV) and resulted CBCT image with a lack of peripheral area of patient body prevents the reliability of dose calculation. In this study, we aim to develop an FOV expanded CBCT in IGRT system to allow the dose calculation. Methods: Three lung cancer patients were selected in this study. We collected the cone-beam projection images in the CBCT-based IGRT system (X-ray volume imaging unit, ELEKTA), where FOV size of the provided CBCT with these projections was 410 × 410 mm{sup 2} (normal FOV). Using these projections, CBCT with a size of 728 × 728 mm{sup 2} was reconstructed by a posteriori estimation algorithm including a prior image constrained compressed sensing (PICCS). The treatment planning CT was used as a prior image. To assess the effectiveness of FOV expansion, a dose calculation was performed on the expanded CBCT image with region-of-interest (ROI) density mapping method, and it was compared with that of treatment planning CT as well as that of CBCT reconstructed by filtered back projection (FBP) algorithm. Results: A posteriori estimation algorithm with PICCS clearly visualized an area outside normal FOV, whereas the FBP algorithm yielded severe streak artifacts outside normal FOV due to under-sampling. The dose calculation result using the expanded CBCT agreed with that using treatment planning CT very well; a maximum dose difference was 1.3% for gross tumor volumes. Conclusion: With a posteriori estimation algorithm, FOV in CBCT can be expanded. Dose comparison results suggested that the use of expanded CBCTs is acceptable for dose calculation in adaptive radiation therapy. This study has been supported by KAKENHI (15K08691).

  17. Useful field of view as a reliable screening measure of driving performance in people with Parkinson's disease: results of a pilot study.

    Science.gov (United States)

    Classen, S; McCarthy, D P; Shechtman, O; Awadzi, K D; Lanford, D N; Okun, M S; Rodriguez, R L; Romrell, J; Bridges, S; Kluger, B; Fernandez, H H

    2009-12-01

    To determine the correlations of the Useful Field of View (UFOV), compared to other clinical tests of Parkinson's disease (PD); vision; and cognition with measures of on-road driving assessments and to quantify the UFOV's ability to indicate passing/failing an on-road test in people with PD. Nineteen randomly selected people with idiopathic PD, mean age = 74.8 (6.1), 14 (73.7%) men, 18 (94.7%) Caucasians, were age-matched to 104 controls without PD. The controls had a mean age of 75.4 (6.4), 59 (56.7%) men, 96 (92.3%) Caucasians. Both groups were referred for a driving evaluation after institutional review board approval. Compared to neuropsychological and clinical tests of vision and cognition, the UFOV showed the strongest correlations (r > .75, p driving errors. Among PD patients, the UFOV Risk Index score of 3 (range 1-5) was established as the optimal cutoff value for passing the on-road test, with sensitivity 87 percent and specificity 82 percent, AUC = 92 percent (SE 0.61, p = .002). Similarly, the UFOV 2 (divided attention) optimum cutoff value is 223 ms (range 16-500 ms), sensitivity 87.5 percent, specificity 81.8 percent, AUC = 91 percent (SE 0.73, p = .003). The UFOV 3 (selected attention) optimal cutoff value is 273 ms (range 16-500 ms), sensitivity 75 percent, specificity 72.7 percent, AUC = 87 percent (SE 0.81, p = .007). In this pilot study among PD patients, the UFOV may be a superior screening measure (compared to other measures of disease, cognition, and vision) for predicting on-road driving performance but its rigor must be verified in a larger sample of people with PD.

  18. Rarity of isolated pulmonary embolism and acute aortic syndrome occurring outside of the field of view of dedicated coronary CT angiography

    International Nuclear Information System (INIS)

    Lee, Hwa Yeon; Song, In Sup; Yoo, Seung Min; Rho, Ji Young; Moon, Jae Youn; Kim, In Jai; Lim, Sang Wook; Sung, Jung Hoon; Cha, Dong Hun; White, Charles S.

    2011-01-01

    Background Although triple rule-out CT angiography (TRO) to simultaneously evaluate acute coronary syndrome (ACS), pulmonary embolism (PE), and acute aortic syndrome (AAS) is increasingly used in many institutions, TRO is inevitably associated with increased radiation exposure due to extended z-axis coverage compared with dedicated coronary CT angiography (DCTA). Purpose To determine the frequency of exclusion of findings of AAS, PE, and significant incidental non-cardiac pathology that may be the cause of acute chest pain when using a restricted DCTA field of view (FOV). Material and Methods We retrospectively reviewed CT images and charts of 103 patients with acute PE and 50 patients with AAS. Either non-ECG gated dedicated pulmonary or aortic CT angiography was performed using 16- or 64-slice multidetector CT (MDCT). We analyzed the incidence of isolated PE, AAS, or significant non-cardiac pathology outside of DCTA FOV (i.e. from tracheal carina to the base of heart). Results There were two cases of isolated PE (2/103, 1.9%) excluded from the FOV of DCTA. One case of PE was isolated to the subsegmental pulmonary artery in the posterior segment of the right upper lobe. In the second case, pulmonary embolism in the left main pulmonary artery was located out of the FOV of DCTA because the left main pulmonary artery was retracted upwardly by fibrotic scar in the left upper lobe due to prior tuberculosis. There was no case of AAS and significant non-cardiac pathology excluded from the FOV of DCTA. AAS (n = 50) consisted of penetrating atherosclerotic ulcer (n = 7), intramural hematoma (n = 5) and aortic dissection (n = 38). Conclusion As isolated PE, AAS, and significant non-cardiac pathology outside of the DCTA FOV rarely occur, DCTA may replace TRO in the evaluation of patients with non-specific acute chest pain and a low pre-test probability of PE or aortic dissection

  19. Rarity of isolated pulmonary embolism and acute aortic syndrome occurring outside of the field of view of dedicated coronary CT angiography

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Hwa Yeon; Song, In Sup (Dept. of Diagnostic Radiology Chung-Ang Univ. College of Medicine, Seoul (Korea, Republic of)); Yoo, Seung Min; Rho, Ji Young (Dept. of Diagnostic Radiology CHA Medical Univ. Hospital, Bundang (Korea, Republic of)), email: smyoo68@hanmail.net; Moon, Jae Youn; Kim, In Jai; Lim, Sang Wook; Sung, Jung Hoon; Cha, Dong Hun (Dept. of Cardiology CHA Medical Univ. Hospital, Bundang (Korea, Republic of)); White, Charles S. (Dept. of Diagnostic Radiology Univ. of Maryland, Baltimore (United States))

    2011-05-15

    Background Although triple rule-out CT angiography (TRO) to simultaneously evaluate acute coronary syndrome (ACS), pulmonary embolism (PE), and acute aortic syndrome (AAS) is increasingly used in many institutions, TRO is inevitably associated with increased radiation exposure due to extended z-axis coverage compared with dedicated coronary CT angiography (DCTA). Purpose To determine the frequency of exclusion of findings of AAS, PE, and significant incidental non-cardiac pathology that may be the cause of acute chest pain when using a restricted DCTA field of view (FOV). Material and Methods We retrospectively reviewed CT images and charts of 103 patients with acute PE and 50 patients with AAS. Either non-ECG gated dedicated pulmonary or aortic CT angiography was performed using 16- or 64-slice multidetector CT (MDCT). We analyzed the incidence of isolated PE, AAS, or significant non-cardiac pathology outside of DCTA FOV (i.e. from tracheal carina to the base of heart). Results There were two cases of isolated PE (2/103, 1.9%) excluded from the FOV of DCTA. One case of PE was isolated to the subsegmental pulmonary artery in the posterior segment of the right upper lobe. In the second case, pulmonary embolism in the left main pulmonary artery was located out of the FOV of DCTA because the left main pulmonary artery was retracted upwardly by fibrotic scar in the left upper lobe due to prior tuberculosis. There was no case of AAS and significant non-cardiac pathology excluded from the FOV of DCTA. AAS (n = 50) consisted of penetrating atherosclerotic ulcer (n = 7), intramural hematoma (n = 5) and aortic dissection (n = 38). Conclusion As isolated PE, AAS, and significant non-cardiac pathology outside of the DCTA FOV rarely occur, DCTA may replace TRO in the evaluation of patients with non-specific acute chest pain and a low pre-test probability of PE or aortic dissection

  20. Design drivers for a wide-field multi-object spectrograph for the William Herschel Telescope

    NARCIS (Netherlands)

    Balcells, Marc; Benn, Chris R.; Carter, David; Dalton, Gavin B.; Trager, Scott C.; Feltzing, Sofia; Verheijen, M.A.W.; Jarvis, Matt; Percival, Will; Abrams, Don C.; Agocs, Tibor; Brown, Anthony G. A.; Cano, Diego; Evans, Chris; Helmi, Amina; Lewis, Ian J.; McLure, Ross; Peletier, Reynier F.; Pérez-Fournon, Ismael; Sharples, Ray M.; Tosh, Ian A. J.; Trujillo, Ignacio; Walton, Nic; Westhall, Kyle B.

    Wide-field multi-object spectroscopy is a high priority for European astronomy over the next decade. Most 8-10m telescopes have a small field of view, making 4-m class telescopes a particularly attractive option for wide-field instruments. We present a science case and design drivers for a

  1. SU-G-IeP4-09: Method of Human Eye Aberration Measurement Using Plenoptic Camera Over Large Field of View

    Energy Technology Data Exchange (ETDEWEB)

    Lv, Yang; Wang, Ruixing; Ma, Haotong; Zhang, Xuanzhe; Ning, Yu; Xu, Xiaojun [College of Optoelectronic Science and Engineering, National University of Defense Technology, Changsha (China)

    2016-06-15

    Purpose: The measurement based on Shack-Hartmann wave-front sensor(WFS), obtaining both the high and low order wave-front aberrations simultaneously and accurately, has been applied in the detection of human eyes aberration in recent years. However, Its application is limited by the small field of view (FOV), slight eye movement leads the optical bacon image exceeds the lenslet array which result in uncertain detection error. To overcome difficulties of precise eye location, the capacity of detecting eye wave-front aberration over FOV much larger than simply a single conjugate Hartmann WFS accurately and simultaneously is demanded. Methods: Plenoptic camera’s lenslet array subdivides the aperture light-field in spatial frequency domain, capture the 4-D light-field information. Data recorded by plenoptic cameras can be used to extract the wave-front phases associated to the eyes aberration. The corresponding theoretical model and simulation system is built up in this article to discuss wave-front measurement performance when utilizing plenoptic camera as wave-front sensor. Results: The simulation results indicate that the plenoptic wave-front method can obtain both the high and low order eyes wave-front aberration with the same accuracy as conventional system in single visual angle detectionand over FOV much larger than simply a single conjugate Hartmann systems. Meanwhile, simulation results show that detection of eye aberrations wave-front in different visual angle can be achieved effectively and simultaneously by plenoptic method, by both point and extended optical beacon from the eye. Conclusion: Plenoptic wave-front method possesses the feasibility in eye aberrations wave-front detection. With larger FOV, the method can effectively reduce the detection error brought by imprecise eye location and simplify the eye aberrations wave-front detection system comparing with which based on Shack-Hartmann WFS. Unique advantage of the plenoptic method lies in obtaining

  2. SU-G-IeP4-09: Method of Human Eye Aberration Measurement Using Plenoptic Camera Over Large Field of View

    International Nuclear Information System (INIS)

    Lv, Yang; Wang, Ruixing; Ma, Haotong; Zhang, Xuanzhe; Ning, Yu; Xu, Xiaojun

    2016-01-01

    Purpose: The measurement based on Shack-Hartmann wave-front sensor(WFS), obtaining both the high and low order wave-front aberrations simultaneously and accurately, has been applied in the detection of human eyes aberration in recent years. However, Its application is limited by the small field of view (FOV), slight eye movement leads the optical bacon image exceeds the lenslet array which result in uncertain detection error. To overcome difficulties of precise eye location, the capacity of detecting eye wave-front aberration over FOV much larger than simply a single conjugate Hartmann WFS accurately and simultaneously is demanded. Methods: Plenoptic camera’s lenslet array subdivides the aperture light-field in spatial frequency domain, capture the 4-D light-field information. Data recorded by plenoptic cameras can be used to extract the wave-front phases associated to the eyes aberration. The corresponding theoretical model and simulation system is built up in this article to discuss wave-front measurement performance when utilizing plenoptic camera as wave-front sensor. Results: The simulation results indicate that the plenoptic wave-front method can obtain both the high and low order eyes wave-front aberration with the same accuracy as conventional system in single visual angle detectionand over FOV much larger than simply a single conjugate Hartmann systems. Meanwhile, simulation results show that detection of eye aberrations wave-front in different visual angle can be achieved effectively and simultaneously by plenoptic method, by both point and extended optical beacon from the eye. Conclusion: Plenoptic wave-front method possesses the feasibility in eye aberrations wave-front detection. With larger FOV, the method can effectively reduce the detection error brought by imprecise eye location and simplify the eye aberrations wave-front detection system comparing with which based on Shack-Hartmann WFS. Unique advantage of the plenoptic method lies in obtaining

  3. SU-F-207-09: Evaluating the Dosimetric Accuracy of Extended Field-Of-View CT Reconstructions Using Clinical Data with Real Patient Geometries

    Energy Technology Data Exchange (ETDEWEB)

    Shugard, E; Cheung, J; Pouliot, J; Chen, J [University of California San Francisco, San Francisco (United States); Mistry, N [Siemens Healthcare USA, Malvern, PA (United States)

    2015-06-15

    Purpose: To determine the accuracy of dose calculations performed with CT images reconstructed using extended field of view (FOV) algorithms. Methods: In this study we selected 6 radiotherapy patients (3 head and neck & 3 chest/pelvis) whose body circumferences extended past the 50 cm scan FOV in the treatment planning CT. Images acquired on a Siemens Sensation Open scanner, were reconstructed using the standard FOV (sFOV) and two different extended FOV algorithms, eFOV and HDFOV. A physician and dosimetrist identified the radiation target, critical organs, and external patient contour. A benchmark CT was created for each patient, consisting of an average of the 3 CT reconstructions with a density override applied to regions containing truncation artifacts, and was used to create an optimal radiation treatment plan. The plan was copied onto each reconstruction without density override and dose was recalculated. Results: The native sFOV dose calculations had the largest deviation from the benchmark (0.4 – 6.0%). Both the HDFOV and eFOV calculations showed improvement over the sFOV. For patients with a smooth patient contour, the HDFOV calculation had the least deviation from the benchmark (0.1–0.5%) compared to eFOV (0.4–1.8%). In cases with large amounts of tissue and irregular skin folds, the eFOV deviated the least from the benchmark (0.2–0.6%) compared to HDFOV (1.3–1.8%). It was observed that the eFOV scan has large image artifact in air with an average HU of −600 compared to the ideal of −1000. In these cases, the artifact in air appears to attenuate the dose and compensate for the missing tissue density. The HDFOV demonstrated minimal artifact in air. Conclusion: Both eFOV and HDFOV provide improved dose calculation accuracy. The HDFOV reconstruction provides a clearer patient border than the eFOV allowing for well-defined density overrides to be applied with minimal air artifact. This research was supported by Siemens Medical Solutions.

  4. A phase-contrast X-ray imaging system--with a 60x30 mm field of view--based on a skew-symmetric two-crystal X-ray interferometer

    Energy Technology Data Exchange (ETDEWEB)

    Yoneyama, Akio E-mail: a-yoneya@rd.hitachi.co.jp; Takeda, Tohoru; Tsuchiya, Yoshinori; Wu Jin; Lwin, T.-T.; Koizumi, Aritaka; Hyodo, Kazuyuki; Itai, Yuji

    2004-05-01

    A phase-contrast X-ray imaging system - with a 60x30 mm field of view - for biomedical observations was developed. To extend the observation field of view, the system is fitted with a skew-symmetric two-crystal X-ray interferometer. To attain the required sub-nanoradian mechanical stability between the crystal blocks for precise operation, the interferometer was mounted on two extremely rigid positioning tables (one with a sleeve bearings) and was controlled by a feedback positioning system using phase-lock interferometry. The imaging system produced a 60x30 mm interference pattern with 60% visibility using 17.7 keV monochromatic synchrotron X-rays at the Photon Factory. It was then used to perform radiographic observation (i.e., phase mapping) of rat liver vessels. These results indicate that this imaging system can be used to perform observations of large and in vivo biological samples.

  5. A phase-contrast X-ray imaging system--with a 60x30 mm field of view--based on a skew-symmetric two-crystal X-ray interferometer

    International Nuclear Information System (INIS)

    Yoneyama, Akio; Takeda, Tohoru; Tsuchiya, Yoshinori; Wu Jin; Lwin, T.-T.; Koizumi, Aritaka; Hyodo, Kazuyuki; Itai, Yuji

    2004-01-01

    A phase-contrast X-ray imaging system - with a 60x30 mm field of view - for biomedical observations was developed. To extend the observation field of view, the system is fitted with a skew-symmetric two-crystal X-ray interferometer. To attain the required sub-nanoradian mechanical stability between the crystal blocks for precise operation, the interferometer was mounted on two extremely rigid positioning tables (one with a sleeve bearings) and was controlled by a feedback positioning system using phase-lock interferometry. The imaging system produced a 60x30 mm interference pattern with 60% visibility using 17.7 keV monochromatic synchrotron X-rays at the Photon Factory. It was then used to perform radiographic observation (i.e., phase mapping) of rat liver vessels. These results indicate that this imaging system can be used to perform observations of large and in vivo biological samples

  6. Reduced field-of -view diffusion-weighted magnetic resonance imaging of the pancreas: Comparison with conventional single-shot echo-planar imaging

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Hyung Jin; Lee, Jeong Min; Yoon, Jeong Hee; Jang, Jin Young; Kim, Sun Whe; Ryu, Ji Kon; Han, Joon Koo; Choi, Byung Ihn [Seoul National University Hospital, Seoul (Korea, Republic of); Kannengiesser, Stephan [Siemens Healthcare, Erlangen (Germany)

    2015-12-15

    To investigate the image quality (IQ) and apparent diffusion coefficient (ADC) of reduced field-of-view (FOV) diffusion-weighted imaging (DWI) of pancreas in comparison with full FOV DWI. In this retrospective study, 2 readers independently performed qualitative analysis of full FOV DWI (FOV, 38 × 38 cm; b-value, 0 and 500 s/mm{sup 2}) and reduced FOV DWI (FOV, 28 × 8.5 cm; b-value, 0 and 400 s/mm{sup 2}). Both procedures were conducted with a two-dimensional spatially selective radiofrequency excitation pulse, in 102 patients with benign or malignant pancreatic diseases (mean size, 27.5 ± 14.4 mm). The study parameters included 1) anatomic structure visualization, 2) lesion conspicuity, 3) artifacts, 4) IQ score, and 5) subjective clinical utility for confirming or excluding initially considered differential diagnosis on conventional imaging. Another reader performed quantitative ADC measurements of focal pancreatic lesions and parenchyma. Wilcoxon signed-rank test was used to compare qualitative scores and ADCs between DWI sequences. Mann Whitney U-test was used to compare ADCs between the lesions and parenchyma. On qualitative analysis, reduced FOV DWI showed better anatomic structure visualization (2.76 ± 0.79 at b = 0 s/mm{sup 2} and 2.81 ± 0.64 at b = 400 s/mm{sup 2}), lesion conspicuity (3.11 ± 0.99 at b = 0 s/mm{sup 2} and 3.15 ± 0.79 at b = 400 s/mm{sup 2}), IQ score (8.51 ± 2.05 at b = 0 s/mm{sup 2} and 8.79 ± 1.60 at b = 400 s/mm{sup 2}), and higher clinical utility (3.41 ± 0.64), as compared to full FOV DWI (anatomic structure, 2.18 ± 0.59 at b = 0 s/mm{sup 2} and 2.56 ± 0.47 at b = 500 s/mm{sup 2}; lesion conspicuity, 2.55 ± 1.07 at b = 0 s/mm{sup 2} and 2.89 ± 0.86 at b = 500 s/mm{sup 2}; IQ score, 7.13 ± 1.83 at b = 0 s/mm{sup 2} and 8.17 ± 1.31 at b = 500 s/mm{sup 2}; clinical utility, 3.14 ± 0.70) (p < 0.05). Artifacts were significantly improved on reduced FOV DWI (2.65 ± 0.68) at b = 0 s/mm{sup 2} (full FOV DWI, 2.41 ± 0.63) (p

  7. Peak-to-valley ratios for three different HPGe detectors for the assessment of 137Cs deposition on the ground and the impact of the detector field-of-view.

    Science.gov (United States)

    Östlund, Karl; Samuelsson, Christer; Mattsson, Sören; Rääf, Christopher L

    2017-02-01

    The peak-to-valley (PTV) method was investigated experimentally comparing PTV ratios for three HPGe detectors, with complementary Monte Carlo simulations of scatter in air for larger source-detector distances. The measured PTV ratios for 137Cs in air were similar for three different detectors for incident angles between 0 and 90°. The study indicated that the PTV method can differentiate between surface and shallow depth sources if the detector field of view is limited to a radius of less than 3.5m. Copyright © 2016 Elsevier Ltd. All rights reserved.

  8. Chlorophyll-a, Orbview-2 SeaWiFS, 0.04167 degrees, Alaska, Science Quality

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — NASA GSFC Ocean Color Web distributes science-quality chlorophyll-a concentration data from the Sea-viewing Wide Field-of-view Sensor (SeaWiFS) on the Orbview-2...

  9. Chlorophyll-a, Orbview-2 SeaWiFS, 0.0125 degrees, West US

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — NOAA CoastWatch distributes chlorophyll-a concentration images from the Sea-viewing Wide Field-of-view Sensor (SeaWiFS) on the Orbview-2 satellite. Because data is...

  10. Do cold, low salinity waters pass through the Indo-Sri Lanka Channel during winter?

    Digital Repository Service at National Institute of Oceanography (India)

    Rao, R.R.; Girishkumar, M.S.; Ravichandran, M.; Gopalakrishna, V.V.; Pankajakshan, T.

    -navigable shallow ISLC, the observed high resolution, advanced very high resolution radiometer (AVHRR) sea surface temperature (SST), and sea-viewing wide field-of-view sensor (SeaWiFS) chlorophyll-a and historic sea surface salinity (SSS) data are utilized...

  11. Comparison of measured and satellite-derived spectral diffuse attenuation coefficients for the Arabian Sea

    Digital Repository Service at National Institute of Oceanography (India)

    Suresh, T.; Talaulikar, M.; Desa, E.; Matondkar, S.G.P.; Mascarenhas, A.

    The results of study comparing the spectral diffuse attenuation coefficients Kd(Lambda) measured in the Arabian Sea with those derived from the Sea-Viewing Wide Field-of-View Sensor (SeaWiFS) using three algorithms, of which two are empirical...

  12. Estimation of colored dissolved organic matter and salinity fields in ...

    Indian Academy of Sciences (India)

    R. Narasimhan (Krishtel eMaging) 1461 1996 Oct 15 13:05:22

    the two algorithms produced more realistic estimates of Chl and CDOM distributions in Florida. Shelf and Bay waters. ... Sea-viewing Wide Field-of-view Sensor (SeaWiFS,. Hooker et al ..... visible bands. The use of the multi-waveband semi-.

  13. SIMBIOS Normalized Water-Leaving Radiance Calibration and Validation: Sensor Response, Atmospheric Corrections, Stray Light and Sun Glint. Chapter 14

    Science.gov (United States)

    Mueller, James L.

    2001-01-01

    This Sensor Intercomparison and Merger for Biological and Interdisciplinary Oceanic Studies (SIMBIOS) contract supports acquisition of match up radiometric and bio-optical data for validation of Sea-Viewing Wide Field-of-view Sensor (SeaWiFS) and other ocean color satellites, and evaluation of uncertainty budgets and protocols for in situ measurements of normalized water leaving radiances.

  14. Thermocline Regulated Seasonal Evolution of Surface Chlorophyll in the Gulf of Aden

    KAUST Repository

    Yao, Fengchao; Hoteit, Ibrahim

    2015-01-01

    , the Sea-Viewing Wide Field-of-View Sensor (SeaWiFS) ocean color data reveal that the Gulf of Aden also exhibits a prominent summer chlorophyll bloom and sustains elevated chlorophyll concentrations throughout the fall, and is a biophysical province

  15. OW NASA SeaWIFS Ocean Color

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — The dataset contains satellite-derived sea-surface ocean color (chlorophyll-a) measurements collected by means of the Sea-viewing Wide Field-of-view Sensor (SeaWiFS)...

  16. Chlorophyll-a, Orbview-2 SeaWiFS, 0.1 degrees, Global

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — NASA GSFC Ocean Color Web distributes science-quality chlorophyll-a concentration data from the Sea-viewing Wide Field-of-view Sensor (SeaWiFS) on the Orbview-2...

  17. WFIRST: Astrometry with the Wide-Field Imager

    Science.gov (United States)

    Bellini, Andrea; WFIRST Astrometry Working Group

    2018-01-01

    The wide field of view and stable, sharp images delivered by WFIRST's Wide-Field Imager make it an excellent instrument for astrometry, one of five major discovery areas identified in the 2010 Decadal Survey. Compared to the Hubble Space Telescope, WFIRST's wider field of view with similar image quality will provide hundreds more astrometric targets per image as well as background galaxies and stars with precise positions in the Gaia catalog. In addition, WFIRST will operate in the infrared, a wavelength regime where the most precise astrometry has so far been achieved with adaptive optics images from large ground-based telescopes. WFIRST will provide at least a factor of three improvement in astrometry over the current state of the art in this wavelength range, while spanning a field of view thousands of times larger. WFIRST is thus poised to make major contributions to multiple science topics in which astrometry plays an important role, without major alterations to the planned mission or instrument. We summarize a few of the most compelling science cases where WFIRST astrometry could prove transformational.

  18. The accuracy of linear measurements of maxillary and mandibular edentulous sites in cone-beam computed tomography images with different fields of view and voxel sizes under simulated clinical conditions

    Energy Technology Data Exchange (ETDEWEB)

    Ganguly, Rumpa; Ramesh, Aruna; Pagni, Sarah [Tufts University School of Dental Medicine, Boston (United States)

    2016-06-15

    The objective of this study was to investigate the effect of varying resolutions of cone-beam computed tomography images on the accuracy of linear measurements of edentulous areas in human cadaver heads. Intact cadaver heads were used to simulate a clinical situation. Fiduciary markers were placed in the edentulous areas of 4 intact embalmed cadaver heads. The heads were scanned with two different CBCT units using a large field of view (13 cm×16 cm) and small field of view (5 cm×8 cm) at varying voxel sizes (0.3 mm, 0.2 mm, and 0.16 mm). The ground truth was established with digital caliper measurements. The imaging measurements were then compared with caliper measurements to determine accuracy. The Wilcoxon signed rank test revealed no statistically significant difference between the medians of the physical measurements obtained with calipers and the medians of the CBCT measurements. A comparison of accuracy among the different imaging protocols revealed no significant differences as determined by the Friedman test. The intraclass correlation coefficient was 0.961, indicating excellent reproducibility. Inter-observer variability was determined graphically with a Bland-Altman plot and by calculating the intraclass correlation coefficient. The Bland-Altman plot indicated very good reproducibility for smaller measurements but larger discrepancies with larger measurements. The CBCT-based linear measurements in the edentulous sites using different voxel sizes and FOVs are accurate compared with the direct caliper measurements of these sites. Higher resolution CBCT images with smaller voxel size did not result in greater accuracy of the linear measurements.

  19. Novel X-ray telescopes for wide-field X-ray monitoring

    International Nuclear Information System (INIS)

    Hudec, R.; Inneman, A.; Pina, L.; Sveda, L.

    2005-01-01

    We report on fully innovative very wide-field of view X-ray telescopes with high sensitivity as well as large field of view. The prototypes are very promising, allowing the proposals for space projects with very wide-field Lobster-eye X-ray optics to be considered. The novel telescopes will monitor the sky with unprecedented sensitivity and angular resolution of order of 1 arcmin. They are expected to contribute essentially to study and to understand various astrophysical objects such as AGN, SNe, Gamma-ray bursts (GRBs), X-ray flashes (XRFs), galactic binary sources, stars, CVs, X-ray novae, various transient sources, etc. The Lobster optics based X-ray All Sky Monitor is capable to detect around 20 GRBs and 8 XRFs yearly and this will surely significantly contribute to the related science

  20. Wide Field Radio Transient Surveys

    Science.gov (United States)

    Bower, Geoffrey

    2011-04-01

    The time domain of the radio wavelength sky has been only sparsely explored. Nevertheless, serendipitous discovery and results from limited surveys indicate that there is much to be found on timescales from nanoseconds to years and at wavelengths from meters to millimeters. These observations have revealed unexpected phenomena such as rotating radio transients and coherent pulses from brown dwarfs. Additionally, archival studies have revealed an unknown class of radio transients without radio, optical, or high-energy hosts. The new generation of centimeter-wave radio telescopes such as the Allen Telescope Array (ATA) will exploit wide fields of view and flexible digital signal processing to systematically explore radio transient parameter space, as well as lay the scientific and technical foundation for the Square Kilometer Array. Known unknowns that will be the target of future transient surveys include orphan gamma-ray burst afterglows, radio supernovae, tidally-disrupted stars, flare stars, and magnetars. While probing the variable sky, these surveys will also provide unprecedented information on the static radio sky. I will present results from three large ATA surveys (the Fly's Eye survey, the ATA Twenty CM Survey (ATATS), and the Pi GHz Survey (PiGSS)) and several small ATA transient searches. Finally, I will discuss the landscape and opportunities for future instruments at centimeter wavelengths.

  1. Systems, computer-implemented methods, and tangible computer-readable storage media for wide-field interferometry

    Science.gov (United States)

    Lyon, Richard G. (Inventor); Leisawitz, David T. (Inventor); Rinehart, Stephen A. (Inventor); Memarsadeghi, Nargess (Inventor)

    2012-01-01

    Disclosed herein are systems, computer-implemented methods, and tangible computer-readable storage media for wide field imaging interferometry. The method includes for each point in a two dimensional detector array over a field of view of an image: gathering a first interferogram from a first detector and a second interferogram from a second detector, modulating a path-length for a signal from an image associated with the first interferogram in the first detector, overlaying first data from the modulated first detector and second data from the second detector, and tracking the modulating at every point in a two dimensional detector array comprising the first detector and the second detector over a field of view for the image. The method then generates a wide-field data cube based on the overlaid first data and second data for each point. The method can generate an image from the wide-field data cube.

  2. Wide field x-ray telescopes: Detecting x-ray transients/afterglows related to GRBs

    International Nuclear Information System (INIS)

    Hudec, Rene; Pina, Ladislav; Inneman, Adolf; Gorenstein, Paul

    1998-01-01

    The recent discovery of X-ray afterglows of GRBs opens the possibility of analyses of GRBs by their X-ray detections. However, imaging X-ray telescopes in current use mostly have limited fields of view. Alternative X-ray optics geometries achieving very large fields of view have been theoretically suggested in the 70's but not constructed and used so far. We review the geometries and basic properties of the wide-field X-ray optical systems based on one- and two-dimensional lobster-eye geometry and suggest technologies for their development and construction. First results of the development of double replicated X-ray reflecting flats for use in one-dimensional X-ray optics of lobster-eye type are presented and discussed. The optimum strategy for locating GRBs upon their X-ray counterparts is also presented and discussed

  3. Laser Light-field Fusion for Wide-field Lensfree On-chip Phase Contrast Microscopy of Nanoparticles

    Science.gov (United States)

    Kazemzadeh, Farnoud; Wong, Alexander

    2016-12-01

    Wide-field lensfree on-chip microscopy, which leverages holography principles to capture interferometric light-field encodings without lenses, is an emerging imaging modality with widespread interest given the large field-of-view compared to lens-based techniques. In this study, we introduce the idea of laser light-field fusion for lensfree on-chip phase contrast microscopy for detecting nanoparticles, where interferometric laser light-field encodings acquired using a lensfree, on-chip setup with laser pulsations at different wavelengths are fused to produce marker-free phase contrast images of particles at the nanometer scale. As a proof of concept, we demonstrate, for the first time, a wide-field lensfree on-chip instrument successfully detecting 300 nm particles across a large field-of-view of ~30 mm2 without any specialized or intricate sample preparation, or the use of synthetic aperture- or shift-based techniques.

  4. A wide field X-ray camera

    International Nuclear Information System (INIS)

    Sims, M.; Turner, M.J.L.; Willingale, R.

    1980-01-01

    A wide field of view X-ray camera based on the Dicke or Coded Mask principle is described. It is shown that this type of instrument is more sensitive than a pin-hole camera, or than a scanning survey of a given region of sky for all wide field conditions. The design of a practical camera is discussed and the sensitivity and performance of the chosen design are evaluated by means of computer simulations. The Wiener Filter and Maximum Entropy methods of deconvolution are described and these methods are compared with each other and cross-correlation using data from the computer simulations. It is shown that the analytic expressions for sensitivity used by other workers are confirmed by the simulations, and that ghost images caused by incomplete coding can be substantially eliminated by the use of the Wiener Filter and the Maximum Entropy Method, with some penalty in computer time for the latter. The cyclic mask configuration is compared with the simple mask camera. It is shown that when the diffuse X-ray background dominates, the simple system is more sensitive and has the better angular resolution. When sources dominate the simple system is less sensitive. It is concluded that the simple coded mask camera is the best instrument for wide field imaging of the X-ray sky. (orig.)

  5. 2D-3D registration for cranial radiation therapy using a 3D kV CBCT and a single limited field-of-view 2D kV radiograph.

    Science.gov (United States)

    Munbodh, Reshma; Knisely, Jonathan Ps; Jaffray, David A; Moseley, Douglas J

    2018-05-01

    We present and evaluate a fully automated 2D-3D intensity-based registration framework using a single limited field-of-view (FOV) 2D kV radiograph and a 3D kV CBCT for 3D estimation of patient setup errors during brain radiotherapy. We evaluated two similarity measures, the Pearson correlation coefficient on image intensity values (ICC) and maximum likelihood measure with Gaussian noise (MLG), derived from the statistics of transmission images. Pose determination experiments were conducted on 2D kV radiographs in the anterior-posterior (AP) and left lateral (LL) views and 3D kV CBCTs of an anthropomorphic head phantom. In order to minimize radiation exposure and exclude nonrigid structures from the registration, limited FOV 2D kV radiographs were employed. A spatial frequency band useful for the 2D-3D registration was identified from the bone-to-no-bone spectral ratio (BNBSR) of digitally reconstructed radiographs (DRRs) computed from the 3D kV planning CT of the phantom. The images being registered were filtered accordingly prior to computation of the similarity measures. We evaluated the registration accuracy achievable with a single 2D kV radiograph and with the registration results from the AP and LL views combined. We also compared the performance of the 2D-3D registration solutions proposed to that of a commercial 3D-3D registration algorithm, which used the entire skull for the registration. The ground truth was determined from markers affixed to the phantom and visible in the CBCT images. The accuracy of the 2D-3D registration solutions, as quantified by the root mean squared value of the target registration error (TRE) calculated over a radius of 3 cm for all poses tested, was ICC AP : 0.56 mm, MLG AP : 0.74 mm, ICC LL : 0.57 mm, MLG LL : 0.54 mm, ICC (AP and LL combined): 0.19 mm, and MLG (AP and LL combined): 0.21 mm. The accuracy of the 3D-3D registration algorithm was 0.27 mm. There was no significant difference in mean TRE for the 2D-3D registration

  6. Wide field X-ray telescopes: Detecting X-ray transients/afterglows related to gamma ray bursts

    International Nuclear Information System (INIS)

    Hudec, Rene; Pina, Ladislav; Inneman, Adolf; Gorenstein, Paul; Rezek, Tomas

    1999-01-01

    The recent discovery of X-ray afterglows of GRBs opens the possibility of analyses of GRBs by their X-ray detections. However, imaging X-ray telescopes in current use mostly have limited field of view. Alternative X-ray optics geometries achieving very large fields of view have been theoretically suggested in the 70ies but not constructed and used so far. We review the geometries and basic properties of the wide-field X-ray optical systems based on one- and two-dimensional lobster-eye geometry and suggest technologies for their development and construction. First results of the development of double replicated X-ray reflecting flats for use in one-dimensional X-ray optics of lobster eye type are presented and discussed. Optimum strategy for locating GRBs upon their X-ray counterparts is also presented and discussed

  7. A Wide Field Auroral Imager (WFAI for low Earth orbit missions

    Directory of Open Access Journals (Sweden)

    N. P. Bannister

    2007-03-01

    Full Text Available A comprehensive understanding of the solar wind interaction with Earth's coupled magnetosphere-ionosphere system requires an ability to observe the charged particle environment and auroral activity from the same platform, generating particle and photon image data which are matched in time and location. While unambiguous identification of the particles giving rise to the aurora requires a Low Earth Orbit satellite, obtaining adequate spatial coverage of aurorae with the relatively limited field of view of current space bourne auroral imaging systems requires much higher orbits. A goal for future satellite missions, therefore, is the development of compact, wide field-of-view optics permitting high spatial and temporal resolution ultraviolet imaging of the aurora from small spacecraft in low polar orbit. Microchannel plate optics offer a method of achieving the required performance. We describe a new, compact instrument design which can observe a wide field-of-view with the required spatial resolution. We report the focusing of 121.6 nm radiation using a spherically-slumped, square-pore microchannel plate with a focal length of 32 mm and an F number of 0.7. Measurements are compared with detailed ray-trace simulations of imaging performance. The angular resolution is 2.7±0.2° for the prototype, corresponding to a footprint ~33 km in diameter for an aurora altitude of 110 km and a spacecraft altitude of 800 km. In preliminary analysis, a more recent optic has demonstrated a full width at half maximum of 5.0±0.3 arcminutes, corresponding to a footprint of ~1 km from the same spacecraft altitude. We further report the imaging properties of a convex microchannel plate detector with planar resistive anode readout; this detector, whose active surface has a radius of curvature of only 100 mm, is shown to meet the spatial resolution and sensitivity requirements of the new wide field auroral imager (WFAI.

  8. The design of the wide field monitor for LOFT

    DEFF Research Database (Denmark)

    Brandt, Søren; Hernanz, M.; Alvarez, L.

    2014-01-01

    is designed to carry on-board two instruments with sensitivity in the 2-50 keV range: a 10 m 2 class Large Area Detector (LAD) with a monitor (WFM) making use of coded masks and providing an instantaneous coverage of more than 1/3 of the sky. The prime goal of the WFM...... will be to detect transient sources to be observed by the LAD. However, thanks to its unique combination of a wide field of view (FoV) and energy resolution (better than 500 eV), the WFM will be also an excellent monitoring instrument to study the long term variability of many classes of X-ray sources. The WFM...

  9. SHOK—The First Russian Wide-Field Optical Camera in Space

    Science.gov (United States)

    Lipunov, V. M.; Gorbovskoy, E. S.; Kornilov, V. G.; Panasyuk, M. I.; Amelushkin, A. M.; Petrov, V. L.; Yashin, I. V.; Svertilov, S. I.; Vedenkin, N. N.

    2018-02-01

    Onboard the spacecraft Lomonosov is established two fast, fixed, very wide-field cameras SHOK. The main goal of this experiment is the observation of GRB optical emission before, synchronously, and after the gamma-ray emission. The field of view of each of the cameras is placed in the gamma-ray burst detection area of other devices located onboard the "Lomonosov" spacecraft. SHOK provides measurements of optical emissions with a magnitude limit of ˜ 9-10m on a single frame with an exposure of 0.2 seconds. The device is designed for continuous sky monitoring at optical wavelengths in the very wide field of view (1000 square degrees each camera), detection and localization of fast time-varying (transient) optical sources on the celestial sphere, including provisional and synchronous time recording of optical emissions from the gamma-ray burst error boxes, detected by the BDRG device and implemented by a control signal (alert trigger) from the BDRG. The Lomonosov spacecraft has two identical devices, SHOK1 and SHOK2. The core of each SHOK device is a fast-speed 11-Megapixel CCD. Each of the SHOK devices represents a monoblock, consisting of a node observations of optical emission, the electronics node, elements of the mechanical construction, and the body.

  10. The Wide Field Imager instrument for Athena

    Science.gov (United States)

    Meidinger, Norbert; Barbera, Marco; Emberger, Valentin; Fürmetz, Maria; Manhart, Markus; Müller-Seidlitz, Johannes; Nandra, Kirpal; Plattner, Markus; Rau, Arne; Treberspurg, Wolfgang

    2017-08-01

    ESA's next large X-ray mission ATHENA is designed to address the Cosmic Vision science theme 'The Hot and Energetic Universe'. It will provide answers to the two key astrophysical questions how does ordinary matter assemble into the large-scale structures we see today and how do black holes grow and shape the Universe. The ATHENA spacecraft will be equipped with two focal plane cameras, a Wide Field Imager (WFI) and an X-ray Integral Field Unit (X-IFU). The WFI instrument is optimized for state-of-the-art resolution spectroscopy over a large field of view of 40 amin x 40 amin and high count rates up to and beyond 1 Crab source intensity. The cryogenic X-IFU camera is designed for high-spectral resolution imaging. Both cameras share alternately a mirror system based on silicon pore optics with a focal length of 12 m and large effective area of about 2 m2 at an energy of 1 keV. Although the mission is still in phase A, i.e. studying the feasibility and developing the necessary technology, the definition and development of the instrumentation made already significant progress. The herein described WFI focal plane camera covers the energy band from 0.2 keV to 15 keV with 450 μm thick fully depleted back-illuminated silicon active pixel sensors of DEPFET type. The spatial resolution will be provided by one million pixels, each with a size of 130 μm x 130 μm. The time resolution requirement for the WFI large detector array is 5 ms and for the WFI fast detector 80 μs. The large effective area of the mirror system will be completed by a high quantum efficiency above 90% for medium and higher energies. The status of the various WFI subsystems to achieve this performance will be described and recent changes will be explained here.

  11. Rapid wide-field Mueller matrix polarimetry imaging based on four photoelastic modulators with no moving parts.

    Science.gov (United States)

    Alali, Sanaz; Gribble, Adam; Vitkin, I Alex

    2016-03-01

    A new polarimetry method is demonstrated to image the entire Mueller matrix of a turbid sample using four photoelastic modulators (PEMs) and a charge coupled device (CCD) camera, with no moving parts. Accurate wide-field imaging is enabled with a field-programmable gate array (FPGA) optical gating technique and an evolutionary algorithm (EA) that optimizes imaging times. This technique accurately and rapidly measured the Mueller matrices of air, polarization elements, and turbid phantoms. The system should prove advantageous for Mueller matrix analysis of turbid samples (e.g., biological tissues) over large fields of view, in less than a second.

  12. Wide-field two-dimensional multifocal optical-resolution photoacoustic computed microscopy

    Science.gov (United States)

    Xia, Jun; Li, Guo; Wang, Lidai; Nasiriavanaki, Mohammadreza; Maslov, Konstantin; Engelbach, John A.; Garbow, Joel R.; Wang, Lihong V.

    2014-01-01

    Optical-resolution photoacoustic microscopy (OR-PAM) is an emerging technique that directly images optical absorption in tissue at high spatial resolution. To date, the majority of OR-PAM systems are based on single focused optical excitation and ultrasonic detection, limiting the wide-field imaging speed. While one-dimensional multifocal OR-PAM (1D-MFOR-PAM) has been developed, the potential of microlens and transducer arrays has not been fully realized. Here, we present the development of two-dimensional multifocal optical-resolution photoacoustic computed microscopy (2D-MFOR-PACM), using a 2D microlens array and a full-ring ultrasonic transducer array. The 10 × 10 mm2 microlens array generates 1800 optical foci within the focal plane of the 512-element transducer array, and raster scanning the microlens array yields optical-resolution photoacoustic images. The system has improved the in-plane resolution of a full-ring transducer array from ≥100 µm to 29 µm and achieved an imaging time of 36 seconds over a 10 × 10 mm2 field of view. In comparison, the 1D-MFOR-PAM would take more than 4 minutes to image over the same field of view. The imaging capability of the system was demonstrated on phantoms and animals both ex vivo and in vivo. PMID:24322226

  13. Intact skull chronic windows for mesoscopic wide-field imaging in awake mice

    Science.gov (United States)

    Silasi, Gergely; Xiao, Dongsheng; Vanni, Matthieu P.; Chen, Andrew C. N.; Murphy, Timothy H.

    2016-01-01

    Background Craniotomy-based window implants are commonly used for microscopic imaging, in head-fixed rodents, however their field of view is typically small and incompatible with mesoscopic functional mapping of cortex. New Method We describe a reproducible and simple procedure for chronic through-bone wide-field imaging in awake head-fixed mice providing stable optical access for chronic imaging over large areas of the cortex for months. Results The preparation is produced by applying clear-drying dental cement to the intact mouse skull, followed by a glass coverslip to create a partially transparent imaging surface. Surgery time takes about 30 minutes. A single set-screw provides a stable means of attachment for mesoscale assessment without obscuring the cortical field of view. Comparison with Existing Methods We demonstrate the utility of this method by showing seed-pixel functional connectivity maps generated from spontaneous cortical activity of GCAMP6 signals in both awake and anesthetized mice. Conclusions We propose that the intact skull preparation described here may be used for most longitudinal studies that do not require micron scale resolution and where cortical neural or vascular signals are recorded with intrinsic sensors. PMID:27102043

  14. Geostationary Coastal and Air Pollution Events (GeoCAPE) Wide Angle Spectrometer (WAS)

    Science.gov (United States)

    Kotecki, Carl; Chu, Martha; Mannino, Antonio; Marx, Catherine Trout; Bowers, Gregory A.; Bolognese, Jeffrey A.; Matson, Elizabeth A.; McBirney, Thomas R.; Earle, Cleland P.; Choi, Michael K.; hide

    2014-01-01

    The GeoCAPE Wide Angle Spectrometer (WAS) Study was a revisit of the COEDI Study from 2012. The customer primary goals were to keep mass, volume and cost to a minimum while meeting the science objectives and maximizing flight opportunities by fitting on the largest number of GEO accommodations possible. Riding on a commercial GEO satellite minimizes total mission costs. For this study, it is desired to increase the coverage rate,km2min, while maintaining ground sample size, 375m, and spectral resolution, 0.4-0.5nm native resolution. To be able to do this, the IFOV was significantly increased, hence the wide angle moniker. The field of view for COEDI was +0.6 degrees or (2048) 375m ground pixels. The WAS Threshold (the IDL study baseline design) is +2.4 degrees IDL study baseline design) is +2.4 degrees.

  15. Convergent acoustic field of view in echolocating bats

    DEFF Research Database (Denmark)

    Jakobsen, Lasse; Ratcliffe, John M; Surlykke, Annemarie

    2013-01-01

    Most echolocating bats exhibit a strong correlation between body size and the frequency of maximum energy in their echolocation calls (peak frequency), with smaller species using signals of higher frequency than larger ones. Size-signal allometry or acoustic detection constraints imposed on wavel......Most echolocating bats exhibit a strong correlation between body size and the frequency of maximum energy in their echolocation calls (peak frequency), with smaller species using signals of higher frequency than larger ones. Size-signal allometry or acoustic detection constraints imposed...... on wavelength by preferred prey size have been used to explain this relationship. Here we propose the hypothesis that smaller bats emit higher frequencies to achieve directional sonar beams, and that variable beam width is critical for bats. Shorter wavelengths relative to the size of the emitter translate...... into more directional sound beams. Therefore, bats that emit their calls through their mouths should show a relationship between mouth size and wavelength, driving smaller bats to signals of higher frequency. We found that in a flight room mimicking a closed habitat, six aerial hawking vespertilionid...

  16. Field of View Requirements for Carrier Landing Training

    Science.gov (United States)

    1980-06-01

    descent is guided by the Fresnel Lens Optical Landing System,(FLOLS) which displays a vertically moveable center iight beam (the " meatball ") which...must be kept aligned with rows of stationary horizontal lights. When the aircraft is above or below the correct glideslope, the meatball is seen as above...or below the horizontal reference lights. If the pilot is viewing a centered meatball , and if the aircraft has the correct AOA, the tailhook will be

  17. Methodology to Assess Field of View of Maxillofacial Protective Devices

    Science.gov (United States)

    2012-11-01

    Cameron Station, Alexandria, Virginia 22314. Orders will be expedited if placed through the librarian or other person designated to request documents...be construed as an official Department of the Army position, policy, or decision, unless so designated by other official documentation. Citation of... styles . Results Tables 1 through 4 list the FOV results of the subjective measurements in polar degrees as well as the mean FOV and standard

  18. Internal and external fields of view affect cybersickness

    NARCIS (Netherlands)

    Emmerik, M.L. van; Vries, S.C. de; Bos, J.E.

    2011-01-01

    People playing computer games sometimes experience a form of visually induced motion sickness called cybersickness. This phenomenon poses a problem for the entertainment market as well as the practice of training, where serious gaming is gaining acceptance as a new way of training. Although

  19. System description and analysis. Part 1: Feasibility study for helicopter/VTOL wide-angle simulation image generation display system

    Science.gov (United States)

    1977-01-01

    A preliminary design for a helicopter/VSTOL wide angle simulator image generation display system is studied. The visual system is to become part of a simulator capability to support Army aviation systems research and development within the near term. As required for the Army to simulate a wide range of aircraft characteristics, versatility and ease of changing cockpit configurations were primary considerations of the study. Due to the Army's interest in low altitude flight and descents into and landing in constrained areas, particular emphasis is given to wide field of view, resolution, brightness, contrast, and color. The visual display study includes a preliminary design, demonstrated feasibility of advanced concepts, and a plan for subsequent detail design and development. Analysis and tradeoff considerations for various visual system elements are outlined and discussed.

  20. Wide-area SWIR arrays and active illuminators

    Science.gov (United States)

    MacDougal, Michael; Hood, Andrew; Geske, Jon; Wang, Chad; Renner, Daniel; Follman, David; Heu, Paula

    2012-01-01

    We describe the factors that go into the component choices for a short wavelength (SWIR) imager, which include the SWIR sensor, the lens, and the illuminator. We have shown the factors for reducing dark current, and shown that we can achieve well below 1.5 nA/cm2 for 15 μm devices at 7°C. We have mated our InGaAs detector arrays to 640x512 readout integrated integrated circuits (ROICs) to make focal plane arrays (FPAs). In addition, we have fabricated high definition 1920x1080 FPAs for wide field of view imaging. The resulting FPAs are capable of imaging photon fluxes with wavelengths between 1 and 1.6 microns at low light levels. The dark current associated with these FPAs is extremely low, exhibiting a mean dark current density of 0.26 nA/cm2 at 0°C. FLIR has also developed a high definition, 1920x1080, 15 um pitch SWIR sensor. In addition, FLIR has developed laser arrays that provide flat illumination in scenes that are normally light-starved. The illuminators have 40% wall-plug efficiency and provide low-speckle illumination, provide artifact-free imagery versus conventional laser illuminators.

  1. Non-mydriatic, wide field, fundus video camera

    Science.gov (United States)

    Hoeher, Bernhard; Voigtmann, Peter; Michelson, Georg; Schmauss, Bernhard

    2014-02-01

    We describe a method we call "stripe field imaging" that is capable of capturing wide field color fundus videos and images of the human eye at pupil sizes of 2mm. This means that it can be used with a non-dilated pupil even with bright ambient light. We realized a mobile demonstrator to prove the method and we could acquire color fundus videos of subjects successfully. We designed the demonstrator as a low-cost device consisting of mass market components to show that there is no major additional technical outlay to realize the improvements we propose. The technical core idea of our method is breaking the rotational symmetry in the optical design that is given in many conventional fundus cameras. By this measure we could extend the possible field of view (FOV) at a pupil size of 2mm from a circular field with 20° in diameter to a square field with 68° by 18° in size. We acquired a fundus video while the subject was slightly touching and releasing the lid. The resulting video showed changes at vessels in the region of the papilla and a change of the paleness of the papilla.

  2. Wide field and diffraction limited array camera for SIRTF

    International Nuclear Information System (INIS)

    Fazio, G.G.; Koch, D.G.; Melnick, G.J.

    1986-01-01

    The Infrared Array Camera for the Space Infrared Telescope Facility (SIRTF/IRAC) is capable of two-dimensional photometry in either a wide field or diffraction-limited mode over the wavelength interval from 2 to 30 microns. Three different two-dimensional direct readout (DRO) array detectors are being considered: Band 1-InSb or Si:In (2-5 microns) 128 x 128 pixels, Band 2-Si:Ga (5-18 microns) 64 x 64 pixels, and Band 3-Si:Sb (18-30 microns) 64 x 64 pixels. The hybrid DRO readout architecture has the advantages of low read noise, random pixel access with individual readout rates, and nondestructive readout. The scientific goals of IRAC are discussed, which are the basis for several important requirements and capabilities of the array camera: (1) diffraction-limited resolution from 2-30 microns, (2) use of the maximum unvignetted field of view of SIRTF, (3) simultaneous observations within the three infrared spectral bands, and (4) the capability for broad and narrow bandwidth spectral resolution. A strategy has been developed to minimize the total electronic and environmental noise sources to satisfy the scientific requirements. 7 references

  3. Fabrication of multi-focal microlens array on curved surface for wide-angle camera module

    Science.gov (United States)

    Pan, Jun-Gu; Su, Guo-Dung J.

    2017-08-01

    In this paper, we present a wide-angle and compact camera module that consists of microlens array with different focal lengths on curved surface. The design integrates the principle of an insect's compound eye and the human eye. It contains a curved hexagonal microlens array and a spherical lens. Compared with normal mobile phone cameras which usually need no less than four lenses, but our proposed system only uses one lens. Furthermore, the thickness of our proposed system is only 2.08 mm and diagonal full field of view is about 100 degrees. In order to make the critical microlens array, we used the inkjet printing to control the surface shape of each microlens for achieving different focal lengths and use replication method to form curved hexagonal microlens array.

  4. The influence of distrubing effects on the performance of a wide field coded mask X-ray camera

    International Nuclear Information System (INIS)

    Sims, M.R.; Turner, M.J.L.; Willingale, R.

    1985-01-01

    The coded aperture telescope, or Dicke camera, is seen as an instrument suitable for many applications in X-ray and gamma ray imaging. In this paper the effects of a partially obscuring window mask support or collimator, a detector with limited spatial resolution, and motion of the camera during image integration are considered using a computer simulation of the performance of such a camera. Cross correlation and the Wiener filter are used to deconvolve the data. It is shown that while these effects cause a degradation in performance this is in no case catastrophic. Deterioration of the image is shown to be greatest where strong sources are present in the field of view and is quite small (proportional 10%) when diffuse background is the major element. A comparison between the cyclic mask camera and the single mask camera is made under various conditions and it is shown the single mask camera has a moderate advantage particularly when imaging a wide field of view. (orig.)

  5. Just how wide should 'wide reading' be?

    Science.gov (United States)

    Lipscomb, Martin

    2015-10-01

    Educationalists introduce students to literature search strategies that, with rare exceptions, focus chiefly on the location of primary research reports and systematic reviews of those reports. These sources are, however, unlikely to adequately address the normative and/or metaphysical questions that nurses frequently and legitimately interest themselves in. To meet these interests, non-research texts exploring normative and/or metaphysical topics might and perhaps should, in some situations, be deemed suitable search targets. This seems plausible and, moreover, students are encouraged to 'read widely'. Yet accepting this proposition creates significant difficulties. Specifically, if non-research scholarly sources and artistic or literary (humanities) products dealing with normative/metaphysical issues were included in what are, at present, scientifically orientated searches, it is difficult to draw boundaries around what--if anything--is to be excluded. Engaging with this issue highlights problems with qualitative scholarship's designation as 'evidence'. Thus, absurdly, if qualitative scholarship's findings are labelled evidence because they generate practice-relevant understanding/insight, then any literary or artistic artefact (e.g. a throwaway lifestyle magazine) that generates kindred understandings/insights is presumably also evidence? This conclusion is rejected and it is instead proposed that while artistic, literary, and qualitative inquiries can provide practitioners with powerful and stimulating non-evidential understanding, these sources are not evidence as commonly conceived. © 2015 John Wiley & Sons Ltd.

  6. Aspects of Remote Sensing in the GEOid and Sea level Of the North Atlantic Region (GEOSONAR) Project

    DEFF Research Database (Denmark)

    Hilger, Klaus Baggesen; Nielsen, Allan Aasbjerg; Knudsen, Per

    1999-01-01

    The general objectives of the GEOid and Sea level Of the North Atlantic Region (GEOSONAR) project are presented. These include analyses of the dynamics of the ocean and its characteristics. The analyses are mainly based on remote sensing. As an example a data set obtained by the multi-channel Sea-viewing...... Wide Field-of-view Sensor (SeaWiFs) is analysed. The presentation results include the computed principal components (PC) and the maximum autocorrelation factors (MAF). Both methods are expected to be incorporated into future analyses of the state of the ocean....

  7. SeaWiFS Technical Report Series. Volume 42; Satellite Primary Productivity Data and Algorithm Development: A Science Plan for Mission to Planet Earth

    Science.gov (United States)

    Falkowski, Paul G.; Behrenfeld, Michael J.; Esaias, Wayne E.; Balch, William; Campbell, Janet W.; Iverson, Richard L.; Kiefer, Dale A.; Morel, Andre; Yoder, James A.; Hooker, Stanford B. (Editor); hide

    1998-01-01

    Two issues regarding primary productivity, as it pertains to the Sea-viewing Wide Field-of-view Sensor (SeaWiFS) Program and the National Aeronautics and Space Administration (NASA) Mission to Planet Earth (MTPE) are presented in this volume. Chapter 1 describes the development of a science plan for deriving primary production for the world ocean using satellite measurements, by the Ocean Primary Productivity Working Group (OPPWG). Chapter 2 presents discussions by the same group, of algorithm classification, algorithm parameterization and data availability, algorithm testing and validation, and the benefits of a consensus primary productivity algorithm.

  8. Smoke in the Gulf of Mexico

    Science.gov (United States)

    2002-01-01

    This Sea-viewing Wide Field-of-view Sensor (SeaWiFS) image of the Bay of Campeche, acquired January 17, 2001, shows a 300-kilometer long smoke plume streaming towards the northwest from around 19.4o North and 92o West, the location of the Akal oil field. In the lower right (southeast) corner of the image is the country of El Salvador, site of a magnitude 7.6 earthquake on January 13, 2001. On the Pacific side of Southern Mexico, the productive waters of the Gulf of Tehuantepec are visible. Provided by the SeaWiFS Project, NASA/Goddard Space Flight Center, and ORBIMAGE

  9. Wide-Gap Chalcopyrites

    CERN Document Server

    Siebentritt, Susanne

    2006-01-01

    Chalcopyrites, in particular those with a wide band gap, are fascinating materials in terms of their technological potential in the next generation of thin-film solar cells and in terms of their basic material properties. They exhibit uniquely low defect formation energies, leading to unusual doping and phase behavior and to extremely benign grain boundaries. This book collects articles on a number of those basic material properties of wide-gap chalcopyrites, comparing them to their low-gap cousins. They explore the doping of the materials, the electronic structure and the transport through interfaces and grain boundaries, the formation of the electric field in a solar cell, the mechanisms and suppression of recombination, the role of inhomogeneities, and the technological role of wide-gap chalcopyrites.

  10. Ultra wide band antennas

    CERN Document Server

    Begaud, Xavier

    2013-01-01

    Ultra Wide Band Technology (UWB) has reached a level of maturity that allows us to offer wireless links with either high or low data rates. These wireless links are frequently associated with a location capability for which ultimate accuracy varies with the inverse of the frequency bandwidth. Using time or frequency domain waveforms, they are currently the subject of international standards facilitating their commercial implementation. Drawing up a complete state of the art, Ultra Wide Band Antennas is aimed at students, engineers and researchers and presents a summary of internationally recog

  11. Dual-conjugate adaptive optics for wide-field high-resolution retinal imaging.

    Science.gov (United States)

    Thaung, Jörgen; Knutsson, Per; Popovic, Zoran; Owner-Petersen, Mette

    2009-03-16

    We present analysis and preliminary laboratory testing of a real-time dual-conjugate adaptive optics (DCAO) instrument for ophthalmology that will enable wide-field high resolution imaging of the retina in vivo. The setup comprises five retinal guide stars (GS) and two deformable mirrors (DM), one conjugate to the pupil and one conjugate to a plane close to the retina. The DCAO instrument has a closed-loop wavefront sensing wavelength of 834 nm and an imaging wavelength of 575 nm. It incorporates an array of collimator lenses to spatially filter the light from all guide stars using one adjustable iris, and images the Hartmann patterns of multiple reference sources on a single detector. Zemax simulations were performed at 834 nm and 575 nm with the Navarro 99 and the Liou- Brennan eye models. Two correction alternatives were evaluated; conventional single conjugate AO (SCAO, using one GS and a pupil DM) and DCAO (using multiple GS and two DM). Zemax simulations at 575 nm based on the Navarro 99 eye model show that the diameter of the corrected field of view for diffraction-limited imaging (Strehl >or= 0.8) increases from 1.5 deg with SCAO to 6.5 deg using DCAO. The increase for the less stringent condition of a wavefront error of 1 rad or less (Strehl >or= 0.37) is from 3 deg with SCAO to approximately 7.4 deg using DCAO. Corresponding results for the Liou-Brennan eye model are 3.1 deg (SCAO) and 8.2 deg (DCAO) for Strehl >or= 0.8, and 4.8 deg (SCAO) and 9.6 deg (DCAO) for Strehl >or= 0.37. Potential gain in corrected field of view with DCAO is confirmed both by laboratory experiments on a model eye and by preliminary in vivo imaging of a human eye. (c) 2009 Optical Society of America

  12. World wide biomass resources

    NARCIS (Netherlands)

    Faaij, A.P.C.

    2012-01-01

    In a wide variety of scenarios, policy strategies, and studies that address the future world energy demand and the reduction of greenhouse gas emissions, biomass is considered to play a major role as renewable energy carrier. Over the past decades, the modern use of biomass has increased

  13. Wide angle isotope separator

    International Nuclear Information System (INIS)

    Kantrowitz, A.

    1976-01-01

    A method and apparatus is described for particle separation. The method uses a wide angle radially expanding vapor of a particle mixture. In particular, selective ionization of one isotope type in the particle mixture is produced in a multichamber separator and the ionized isotope type is accelerated out of the path of the vapor expansion for separate collection

  14. Jihadism, Narrow and Wide

    DEFF Research Database (Denmark)

    Sedgwick, Mark

    2015-01-01

    The term “jihadism” is popular, but difficult. It has narrow senses, which are generally valuable, and wide senses, which may be misleading. This article looks at the derivation and use of “jihadism” and of related terms, at definitions provided by a number of leading scholars, and at media usage....... It distinguishes two main groups of scholarly definitions, some careful and narrow, and some appearing to match loose media usage. However, it shows that even these scholarly definitions actually make important distinctions between jihadism and associated political and theological ideology. The article closes...

  15. With eyes wide open

    DEFF Research Database (Denmark)

    Frølunde, Lisbeth; Pedersen, Chistina Hee

    2013-01-01

    and that vulnerability and discomfort are often overlooked as transformative forces. The analysis draws on data from a classroom context in which university students tested methods for facilitating creative thinking in a course on data production and creativity. The data stem from a session on the method “Lego Serious...... in constructions of group identity when an external facilitator disrupts a context. We argue that the facilitation of creative methods calls for keeping our eyes wide open for tensions, for they are the mulch that improves the soil....

  16. World wide spatial capital.

    Science.gov (United States)

    Sen, Rijurekha; Quercia, Daniele

    2018-01-01

    In its most basic form, the spatial capital of a neighborhood entails that most aspects of daily life are located close at hand. Urban planning researchers have widely recognized its importance, not least because it can be transformed in other forms of capital such as economical capital (e.g., house prices, retail sales) and social capital (e.g., neighborhood cohesion). Researchers have already studied spatial capital from official city data. Their work led to important planning decisions, yet it also relied on data that is costly to create and update, and produced metrics that are difficult to compare across cities. By contrast, we propose to measure spatial capital in cheap and standardized ways around the world. Hence the name of our project "World Wide Spatial Capital". Our measures are cheap as they rely on the most basic information about a city that is currently available on the Web (i.e., which amenities are available and where). They are also standardized because they can be applied in any city in the five continents (as opposed to previous metrics that were mainly applied in USA and UK). We show that, upon these metrics, one could produce insights at the core of the urban planning discipline: which areas would benefit the most from urban interventions; how to inform planning depending on whether a city's activity is mono- or poly-centric; how different cities fare against each other; and how spatial capital correlates with other urban characteristics such as mobility patterns and road network structure.

  17. The wide-aperture gamma-ray telescope TAIGA-HiSCORE in the Tunka Valley: Design, composition and commissioning

    Energy Technology Data Exchange (ETDEWEB)

    Gress, O., E-mail: grol08@rambler.ru [Institute of Applied Physics ISU, Irkutsk (Russian Federation); Astapov, I. [NRNU MEPhI, Moscow (Russian Federation); Budnev, N.; Bezyazeekov, P. [Institute of Applied Physics ISU, Irkutsk (Russian Federation); Bogdanov, A. [NRNU MEPhI, Moscow (Russian Federation); Boreyko, V. [JINR, Dubna (Russian Federation); Brückner, M. [Institute for Computer Science, Humboldt-University, Berlin (Germany); Chiavassa, A. [Dipartimento di Fisica Generale Universiteta di Torino and INFN, Torino (Italy); Chvalaev, O.; Dyachok, A.; Gress, T. [Institute of Applied Physics ISU, Irkutsk (Russian Federation); Epimakhov, S. [Institut fr Experimentalphysik, University of Hamburg (Germany); Fedoseev, E.; Gafarov, A. [Institute of Applied Physics ISU, Irkutsk (Russian Federation); Gorbunov, N.; Grebenyuk, V.; Grinuk, A. [JINR, Dubna (Russian Federation); Grishin, O. [Institute of Applied Physics ISU, Irkutsk (Russian Federation); Horns, D. [Institut fr Experimentalphysik, University of Hamburg (Germany); Ivanova, A. [Institute of Applied Physics ISU, Irkutsk (Russian Federation); and others

    2017-02-11

    The new TAIGA-HiSCORE non-imaging Cherenkov array aims to detect air showers induced by gamma rays above 30 TeV and to study cosmic rays above 100 TeV. TAIGA-HiSCORE is made of integrating air Cherenkov detector stations with a wide field of view (0.6 sr), placed at a distance of about 100 m. They cover an area of initially ∼0.25 km{sup 2} (prototype array), and of ∼5 km{sup 2} at the final phase of the experiment. Each station includes 4 PMTs with 20 or 25 cm diameter, equipped with light guides shaped as Winstone cones. We describe the design, specifications of the read-out, DAQ and control and monitoring systems of the array. The present 28 detector stations of the TAIGA-HiSCORE engineering setup are in operation since September 2015.

  18. Wide-field LOFAR-LBA power-spectra analyses: Impact of calibration, polarization leakage and ionosphere

    Science.gov (United States)

    Gehlot, Bharat K.; Koopmans, Léon V. E.

    2018-05-01

    Contamination due to foregrounds, calibration errors and ionospheric effects pose major challenges in detection of the cosmic 21 cm signal in various Epoch of Reionization (EoR) experiments. We present the results of a study of a field centered on 3C196 using LOFAR Low Band observations, where we quantify various wide field and calibration effects such as gain errors, polarized foregrounds, and ionospheric effects. We observe a `pitchfork' structure in the power spectrum of the polarized intensity in delay-baseline space, which leaks into the modes beyond the instrumental horizon. We show that this structure arises due to strong instrumental polarization leakage (~30%) towards Cas A which is far away from primary field of view. We measure a small ionospheric diffractive scale towards CasA resembling pure Kolmogorov turbulence. Our work provides insights in understanding the nature of aforementioned effects and mitigating them in future Cosmic Dawn observations.

  19. Imaging design of the wide field x-ray monitor onboard the HETE satellite

    International Nuclear Information System (INIS)

    Zand, J.J.M. In'T; Fenimore, E.E.; Kawai, N.; Yoshida, A.; Matsuoka, M.; Yamauchi, M.

    1994-01-01

    The High Energy Transient Experiment (HETE), to be launched in 1995, will study Gamma-Ray Bursts in an unprecendented wide wavelength range from Gamma- and X-ray to UV wavelengths. The X-ray range (2 to 25 keV) will be covered by 2 perpendicularly oriented 1-dimensional coded aperture cameras. These instruments cover a wide field of view of 2 sr and thus have a relatively large potential to locate GRBs to a fraction of a degree, which is an order of magnitude better than BATSE. The imaging design of these coded aperture cameras relates to the design of the coded apertures and the decoding algorithm. The aperture pattern is to a large extent determined by the high background in this wide field application and the low number of pattern elements (∼100) in each direction. The result is a random pattern with an open fraction of 33%. The onboard decoding algorithm is dedicated to the localization of a single point source

  20. Wide-field optical mapping of neural activity and brain haemodynamics: considerations and novel approaches

    Science.gov (United States)

    Ma, Ying; Shaik, Mohammed A.; Kozberg, Mariel G.; Thibodeaux, David N.; Zhao, Hanzhi T.; Yu, Hang

    2016-01-01

    Although modern techniques such as two-photon microscopy can now provide cellular-level three-dimensional imaging of the intact living brain, the speed and fields of view of these techniques remain limited. Conversely, two-dimensional wide-field optical mapping (WFOM), a simpler technique that uses a camera to observe large areas of the exposed cortex under visible light, can detect changes in both neural activity and haemodynamics at very high speeds. Although WFOM may not provide single-neuron or capillary-level resolution, it is an attractive and accessible approach to imaging large areas of the brain in awake, behaving mammals at speeds fast enough to observe widespread neural firing events, as well as their dynamic coupling to haemodynamics. Although such wide-field optical imaging techniques have a long history, the advent of genetically encoded fluorophores that can report neural activity with high sensitivity, as well as modern technologies such as light emitting diodes and sensitive and high-speed digital cameras have driven renewed interest in WFOM. To facilitate the wider adoption and standardization of WFOM approaches for neuroscience and neurovascular coupling research, we provide here an overview of the basic principles of WFOM, considerations for implementation of wide-field fluorescence imaging of neural activity, spectroscopic analysis and interpretation of results. This article is part of the themed issue ‘Interpreting BOLD: a dialogue between cognitive and cellular neuroscience’. PMID:27574312

  1. Wide-field optical mapping of neural activity and brain haemodynamics: considerations and novel approaches.

    Science.gov (United States)

    Ma, Ying; Shaik, Mohammed A; Kim, Sharon H; Kozberg, Mariel G; Thibodeaux, David N; Zhao, Hanzhi T; Yu, Hang; Hillman, Elizabeth M C

    2016-10-05

    Although modern techniques such as two-photon microscopy can now provide cellular-level three-dimensional imaging of the intact living brain, the speed and fields of view of these techniques remain limited. Conversely, two-dimensional wide-field optical mapping (WFOM), a simpler technique that uses a camera to observe large areas of the exposed cortex under visible light, can detect changes in both neural activity and haemodynamics at very high speeds. Although WFOM may not provide single-neuron or capillary-level resolution, it is an attractive and accessible approach to imaging large areas of the brain in awake, behaving mammals at speeds fast enough to observe widespread neural firing events, as well as their dynamic coupling to haemodynamics. Although such wide-field optical imaging techniques have a long history, the advent of genetically encoded fluorophores that can report neural activity with high sensitivity, as well as modern technologies such as light emitting diodes and sensitive and high-speed digital cameras have driven renewed interest in WFOM. To facilitate the wider adoption and standardization of WFOM approaches for neuroscience and neurovascular coupling research, we provide here an overview of the basic principles of WFOM, considerations for implementation of wide-field fluorescence imaging of neural activity, spectroscopic analysis and interpretation of results.This article is part of the themed issue 'Interpreting BOLD: a dialogue between cognitive and cellular neuroscience'. © 2016 The Authors.

  2. Weaving a wide net.

    Science.gov (United States)

    Garber, Linda

    2002-10-01

    SUMMARY Any single approach tostudents' heterosexism and homophobia, however well conceived and executed, is most successful when supported by an integrated campus approach to the problem. Taking as a model the multifaceted efforts at California State University, Fresno-a large public institution located in what can be considered the state's Bible Belt-this essay discusses the strengths and logistics of a campus-wide program to address homophobia and alleviate LGBTQ students' feelings of alienation from the institution and their oppression in society. The efforts of CSUF take place at a number of different levels-classroom, academic department, student services, faculty networking-and can be considered a successful work in progress.

  3. World wide spatial capital.

    Directory of Open Access Journals (Sweden)

    Rijurekha Sen

    Full Text Available In its most basic form, the spatial capital of a neighborhood entails that most aspects of daily life are located close at hand. Urban planning researchers have widely recognized its importance, not least because it can be transformed in other forms of capital such as economical capital (e.g., house prices, retail sales and social capital (e.g., neighborhood cohesion. Researchers have already studied spatial capital from official city data. Their work led to important planning decisions, yet it also relied on data that is costly to create and update, and produced metrics that are difficult to compare across cities. By contrast, we propose to measure spatial capital in cheap and standardized ways around the world. Hence the name of our project "World Wide Spatial Capital". Our measures are cheap as they rely on the most basic information about a city that is currently available on the Web (i.e., which amenities are available and where. They are also standardized because they can be applied in any city in the five continents (as opposed to previous metrics that were mainly applied in USA and UK. We show that, upon these metrics, one could produce insights at the core of the urban planning discipline: which areas would benefit the most from urban interventions; how to inform planning depending on whether a city's activity is mono- or poly-centric; how different cities fare against each other; and how spatial capital correlates with other urban characteristics such as mobility patterns and road network structure.

  4. Wide area monitoring study

    International Nuclear Information System (INIS)

    Wogman, N.A.; Holdren, G.R. Jr.

    1999-01-01

    Environmental sampling can be used to complement the safeguarding of nuclear material, especially in the detection of undeclared nuclear activities. Routine monitoring of nuclear installations has provided valuable information about the fate of key signature materials within different environmental settings. The approach collates information regarding the generation of individual radiochemical signatures within different nuclear processes, the potential for release of these signatures to the environment and, the chemical form and mobility of the signatures in environmental media along which the material could migrate. Meteorological, geological and hydrological information is used to determine where to sample, what to sample, and how often to sample to provide the greatest likelihood for detection. Multiple strategies can be used to implement wide area monitoring for safeguards purposes. The most complex, and expensive of these, involves establishing extensive networks of fixed location sampling sites. The sites would be operated continuously, and would be instrumented with automated sampling, analysis, and communication equipment to relay information regarding potential anomalies to control centers in near-real time. Alternative strategies can be used to supplement fixed location monitoring equipment, especially in regions that cannot support (financially or logistically) the fixed stations. Through combinations of these various strategies, using a variety of environmental media to monitor a region, we believe that a competent network, one with a quantifiable probability for detecting undeclared nuclear activities, can be designed. While this approach cannot and should not replace other inspection and monitoring activities, it can potentially contribute valuable information to an international safeguards system. (author)

  5. Wide-scan dielectric dome antenna with reduced profile

    NARCIS (Netherlands)

    Gandini, E.; Silvestri, F.; Benini, A.; Gerini, G.; Martini, E.; Maci, S.; Viganò, M.C.; Toso, G.; Monni, S.

    2017-01-01

    In this contribution, a dielectric dome antenna design in Ka-band is presented. The dome antenna is based on the combination of a phased array and a dielectric lens. The goal of the combination of these structures is to enlarge the field of view of the antenna. In particular, the array is considered

  6. Wide Awake Hand Surgery.

    Science.gov (United States)

    Lied, Line; Borchgrevink, Grethe E; Finsen, Vilhjalmur

    2017-09-01

    "Wide awake hand surgery", where surgery is performed in local anaesthesia with adrenaline, without sedation or a tourniquet, has become widespread in some countries. It has a number of potential advantages and we wished to evaluate it among our patients. All 122 patients treated by this method during one year were evaluated by the surgeons and the patients on a numerical scale from 0 (best/least) to 10 (worst/most). Theatre time was compared to that recorded for a year when regional or general anaesthesia had been used. The patients' mean score for the general care they had received was 0.1 (SD 0.6), for pain during lidocaine injection 2.4 (SD 2.2), for pain during surgery 0.9 (SD 1.5), and for other discomfort during surgery 0.5 (SD 1.4). Eight reported that they would want general anaesthesia if they were to be operated again. The surgeons' mean evaluation of bleeding during surgery was 1.6 (SD 1.8), oedema during surgery 0.4 (SD 1.1), general disadvantages with the method 1.0 (SD 1.6) and general advantages 6.5 (SD 4.3). The estimation of advantages was 9.9 (DS 0.5) for tendon suture. 28 patients needed intra-operative additional anaesthesia. The proportion was lower among trained hand surgeons and fell significantly during the study period. Non-surgical theatre time was 46 (SD 15) minutes during the study period and 55 (SD 22) minutes during the regional/general period (p theatre.

  7. Bio-Inspired Wide-Angle Broad-Spectrum Cylindrical Lens Based on Reflections from Micro-Mirror Array on a Cylindrical Elastomeric Membrane

    Directory of Open Access Journals (Sweden)

    Chi-Chieh Huang

    2014-06-01

    Full Text Available We present a wide-angle, broad-spectrum cylindrical lens based on reflections from an array of three-dimensional, high-aspect-ratio micro-mirrors fabricated on a cylindrical elastomeric substrate, functionally inspired by natural reflecting superposition compound eyes. Our device can perform one-dimensional focusing and beam-shaping comparable to conventional refraction-based cylindrical lenses, while avoiding chromatic aberration. The focal length of our cylindrical lens is 1.035 mm, suitable for micro-optical systems. Moreover, it demonstrates a wide field of view of 152° without distortion, as well as modest spherical aberrations. Our work could be applied to diverse applications including laser diode collimation, barcode scanning, holography, digital projection display, microlens arrays, and optical microscopy.

  8. Wide-field Spatio-Spectral Interferometry: Bringing High Resolution to the Far- Infrared

    Science.gov (United States)

    Leisawitx, David

    Wide-field spatio-spectral interferometry combines spatial and spectral interferometric data to provide integral field spectroscopic information over a wide field of view. This technology breaks through a mission cost barrier that stands in the way of resolving spatially and measuring spectroscopically at far-infrared wavelengths objects that will lead to a deep understanding of planetary system and galaxy formation processes. A space-based far-IR interferometer will combine Spitzer s superb sensitivity with a two order of magnitude gain in angular resolution, and with spectral resolution in the thousands. With the possible exception of detector technology, which is advancing with support from other research programs, the greatest challenge for far-IR interferometry is to demonstrate that the interferometer will actually produce the images and spectra needed to satisfy mission science requirements. With past APRA support, our team has already developed the highly specialized hardware testbed, image projector, computational model, and image construction software required for the proposed effort, and we have access to an ideal test facility.

  9. Simple concept for a wide-field lensless digital holographic microscope using a laser diode

    Directory of Open Access Journals (Sweden)

    Adinda-Ougba A.

    2015-09-01

    Full Text Available Wide-field, lensless digital holographic microscopy is a new microscopic imaging technique for telemedicine and for resource limited setting [1]. In this contribution we propose a very simple wide-field lensless digital holographic microscope using a laser diode. It is based on in-line digital holography which is capable to provide amplitude and phase images of a sample resulting from numerical reconstruction. The numerical reconstruction consists of the angular spectrum propagation method together with a phase retrieval algorithm. Amplitude and phase images of the sample with a resolution of ∽2 µm and with ∽24 mm2 field of view are obtained. We evaluate our setup by imaging first the 1951 USAF resolution test chart to verify the resolution. Second, we record holograms of blood smear and diatoms. The individual specimen can be easily identified after the numerical reconstruction. Our system is a very simple, compact and low-cost possibility of realizing a microscope capable of imaging biological samples. The availability of the phase provide topographic information of the sample extending the application of this system to be not only for biological sample but also for transparent microstructure. It is suitable for fault detection, shape and roughness measurements of these structures.

  10. The Wide Field Imager of the International X-ray Observatory

    Energy Technology Data Exchange (ETDEWEB)

    Stefanescu, A., E-mail: astefan@hll.mpg.d [Max-Planck-Institut Halbleiterlabor, Otto-Hahn-Ring 6, 81739 Muenchen (Germany); Johannes Gutenberg-Universitaet, Inst. f. anorganische und analytische Chemie, 55099 Mainz (Germany); Bautz, M.W. [Kavli Institute for Astrophysics and Space Research, Massachusetts Institute of Technology, Cambridge, MA 02139-4307 (United States); Burrows, D.N. [Department of Astronomy and Astrophysics, Pennsylvania State University, University Park, PA 16802 (United States); Bombelli, L.; Fiorini, C. [Politecnico di Milano, Dipartimento di Elettronica e Informazione, Milano (Italy); INFN Sezione di Milano, Milano (Italy); Fraser, G. [Space Research Centre, Department of Physics and Astronomy, University of Leicester, University Road, Leicester LE1 7RH (United Kingdom); Heinzinger, K. [PNSensor GmbH, Roemerstr. 28, 80803 Muenchen (Germany); Herrmann, S. [Max-Planck-Institut Halbleiterlabor, Otto-Hahn-Ring 6, 81739 Muenchen (Germany); Max-Planck-Institut fuer extraterrestrische Physik, Giessenbachstr., 85748 Garching (Germany); Kuster, M. [Technische Universitaet Darmstadt, Institut fuer Kernphysik, Schlossgartenstr. 9, 64289 Darmstadt (Germany); Lauf, T. [Max-Planck-Institut Halbleiterlabor, Otto-Hahn-Ring 6, 81739 Muenchen (Germany); Max-Planck-Institut fuer extraterrestrische Physik, Giessenbachstr., 85748 Garching (Germany); Lechner, P. [PNSensor GmbH, Roemerstr. 28, 80803 Muenchen (Germany); Lutz, G. [Max-Planck-Institut Halbleiterlabor, Otto-Hahn-Ring 6, 81739 Muenchen (Germany); Max-Planck-Institut fuer Physik, Foehringer Ring 6, 80805 Muenchen (Germany); Majewski, P. [PNSensor GmbH, Roemerstr. 28, 80803 Muenchen (Germany); Meuris, A. [Max-Planck-Institut Halbleiterlabor, Otto-Hahn-Ring 6, 81739 Muenchen (Germany); Max-Planck-Institut fuer extraterrestrische Physik, Giessenbachstr., 85748 Garching (Germany); Murray, S.S. [Harvard/Smithsonian Center for Astrophysics, 60 Garden St., Cambridge, MA 02138 (United States)

    2010-12-11

    The International X-ray Observatory (IXO) will be a joint X-ray observatory mission by ESA, NASA and JAXA. It will have a large effective area (3 m{sup 2} at 1.25 keV) grazing incidence mirror system with good angular resolution (5 arcsec at 0.1-10 keV) and will feature a comprehensive suite of scientific instruments: an X-ray Microcalorimeter Spectrometer, a High Time Resolution Spectrometer, an X-ray Polarimeter, an X-ray Grating Spectrometer, a Hard X-ray Imager and a Wide-Field Imager. The Wide Field Imager (WFI) has a field-of-view of 18 ftx18 ft. It will be sensitive between 0.1 and 15 keV, offer the full angular resolution of the mirrors and good energy resolution. The WFI will be implemented as a 6 in. wafer-scale monolithical array of 1024x1024 pixels of 100x100{mu}m{sup 2} size. The DEpleted P-channel Field-Effect Transistors (DEPFET) forming the individual pixels are devices combining the functionalities of both detector and amplifier. Signal electrons are collected in a potential well below the transistor's gate, modulating the transistor current. Even when the device is powered off, the signal charge is collected and kept in the potential well below the gate until it is explicitly cleared. This makes flexible and fast readout modes possible.

  11. Wide-Field Imaging Telescope-0 (WIT0) with automatic observing system

    Science.gov (United States)

    Ji, Tae-Geun; Byeon, Seoyeon; Lee, Hye-In; Park, Woojin; Lee, Sang-Yun; Hwang, Sungyong; Choi, Changsu; Gibson, Coyne Andrew; Kuehne, John W.; Prochaska, Travis; Marshall, Jennifer L.; Im, Myungshin; Pak, Soojong

    2018-01-01

    We introduce Wide-Field Imaging Telescope-0 (WIT0), with an automatic observing system. It is developed for monitoring the variabilities of many sources at a time, e.g. young stellar objects and active galactic nuclei. It can also find the locations of transient sources such as a supernova or gamma-ray bursts. In 2017 February, we installed the wide-field 10-inch telescope (Takahashi CCA-250) as a piggyback system on the 30-inch telescope at the McDonald Observatory in Texas, US. The 10-inch telescope has a 2.35 × 2.35 deg field-of-view with a 4k × 4k CCD Camera (FLI ML16803). To improve the observational efficiency of the system, we developed a new automatic observing software, KAOS30 (KHU Automatic Observing Software for McDonald 30-inch telescope), which was developed by Visual C++ on the basis of a windows operating system. The software consists of four control packages: the Telescope Control Package (TCP), the Data Acquisition Package (DAP), the Auto Focus Package (AFP), and the Script Mode Package (SMP). Since it also supports the instruments that are using the ASCOM driver, the additional hardware installations become quite simplified. We commissioned KAOS30 in 2017 August and are in the process of testing. Based on the WIT0 experiences, we will extend KAOS30 to control multiple telescopes in future projects.

  12. High Precision Sunphotometer using Wide Dynamic Range (WDR) Camera Tracking

    Science.gov (United States)

    Liss, J.; Dunagan, S. E.; Johnson, R. R.; Chang, C. S.; LeBlanc, S. E.; Shinozuka, Y.; Redemann, J.; Flynn, C. J.; Segal-Rosenhaimer, M.; Pistone, K.; Kacenelenbogen, M. S.; Fahey, L.

    2016-12-01

    wide dynamic range camera that provides a high precision solar position tracking signal as well as an image of the sky in the 45° field of view around the solar axis, which can be of great assistance in flagging data for cloud effects or other factors that might impact data quality.

  13. Polarization leakage in epoch of reionization windows - III. Wide-field effects of narrow-field arrays

    Science.gov (United States)

    Asad, K. M. B.; Koopmans, L. V. E.; Jelić, V.; de Bruyn, A. G.; Pandey, V. N.; Gehlot, B. K.

    2018-05-01

    Leakage of polarized Galactic diffuse emission into total intensity can potentially mimic the 21-cm signal coming from the epoch of reionization (EoR), as both of them might have fluctuating spectral structure. Although we are sensitive to the EoR signal only in small fields of view, chromatic side-lobes from further away can contaminate the inner region. Here, we explore the effects of leakage into the `EoR window' of the cylindrically averaged power spectra (PS) within wide fields of view using both observation and simulation of the 3C196 and North Celestial Pole (NCP) fields, two observing fields of the LOFAR-EoR project. We present the polarization PS of two one-night observations of the two fields and find that the NCP field has higher fluctuations along frequency, and consequently exhibits more power at high-k∥ that could potentially leak to Stokes I. Subsequently, we simulate LOFAR observations of Galactic diffuse polarized emission based on a model to assess what fraction of polarized power leaks into Stokes I because of the primary beam. We find that the rms fractional leakage over the instrumental k-space is 0.35 {per cent} in the 3C196 field and 0.27 {per cent} in the NCP field, and it does not change significantly within the diameters of 15°, 9°, and 4°. Based on the observed PS and simulated fractional leakage, we show that a similar level of leakage into Stokes I is expected in the 3C196 and NCP fields, and the leakage can be considered to be a bias in the PS.

  14. Camera Trajectory fromWide Baseline Images

    Science.gov (United States)

    Havlena, M.; Torii, A.; Pajdla, T.

    2008-09-01

    Camera trajectory estimation, which is closely related to the structure from motion computation, is one of the fundamental tasks in computer vision. Reliable camera trajectory estimation plays an important role in 3D reconstruction, self localization, and object recognition. There are essential issues for a reliable camera trajectory estimation, for instance, choice of the camera and its geometric projection model, camera calibration, image feature detection and description, and robust 3D structure computation. Most of approaches rely on classical perspective cameras because of the simplicity of their projection models and ease of their calibration. However, classical perspective cameras offer only a limited field of view, and thus occlusions and sharp camera turns may cause that consecutive frames look completely different when the baseline becomes longer. This makes the image feature matching very difficult (or impossible) and the camera trajectory estimation fails under such conditions. These problems can be avoided if omnidirectional cameras, e.g. a fish-eye lens convertor, are used. The hardware which we are using in practice is a combination of Nikon FC-E9 mounted via a mechanical adaptor onto a Kyocera Finecam M410R digital camera. Nikon FC-E9 is a megapixel omnidirectional addon convertor with 180° view angle which provides images of photographic quality. Kyocera Finecam M410R delivers 2272×1704 images at 3 frames per second. The resulting combination yields a circular view of diameter 1600 pixels in the image. Since consecutive frames of the omnidirectional camera often share a common region in 3D space, the image feature matching is often feasible. On the other hand, the calibration of these cameras is non-trivial and is crucial for the accuracy of the resulting 3D reconstruction. We calibrate omnidirectional cameras off-line using the state-of-the-art technique and Mičušík's two-parameter model, that links the radius of the image point r to the

  15. Research on Wide-field Imaging Technologies for Low-frequency Radio Array

    Science.gov (United States)

    Lao, B. Q.; An, T.; Chen, X.; Wu, X. C.; Lu, Y.

    2017-09-01

    Wide-field imaging of low-frequency radio telescopes are subject to a number of difficult problems. One particularly pernicious problem is the non-coplanar baseline effect. It will lead to distortion of the final image when the phase of w direction called w-term is ignored. The image degradation effects are amplified for telescopes with the wide field of view. This paper summarizes and analyzes several w-term correction methods and their technical principles. Their advantages and disadvantages have been analyzed after comparing their computational cost and computational complexity. We conduct simulations with two of these methods, faceting and w-projection, based on the configuration of the first-phase Square Kilometre Array (SKA) low frequency array. The resulted images are also compared with the two-dimensional Fourier transform method. The results show that image quality and correctness derived from both faceting and w-projection are better than the two-dimensional Fourier transform method in wide-field imaging. The image quality and run time affected by the number of facets and w steps have been evaluated. The results indicate that the number of facets and w steps must be reasonable. Finally, we analyze the effect of data size on the run time of faceting and w-projection. The results show that faceting and w-projection need to be optimized before the massive amounts of data processing. The research of the present paper initiates the analysis of wide-field imaging techniques and their application in the existing and future low-frequency array, and fosters the application and promotion to much broader fields.

  16. Deployment of the Hobby-Eberly Telescope wide-field upgrade

    Science.gov (United States)

    Hill, Gary J.; Drory, Niv; Good, John M.; Lee, Hanshin; Vattiat, Brian L.; Kriel, Herman; Ramsey, Jason; Bryant, Randy; Elliot, Linda; Fowler, Jim; Häuser, Marco; Landiau, Martin; Leck, Ron; Odewahn, Stephen; Perry, Dave; Savage, Richard; Schroeder Mrozinski, Emily; Shetrone, Matthew; DePoy, D. L.; Prochaska, Travis; Marshall, J. L.; Damm, George; Gebhardt, Karl; MacQueen, Phillip J.; Martin, Jerry; Armandroff, Taft; Ramsey, Lawrence W.

    2016-07-01

    The Hobby-Eberly Telescope (HET) is an innovative large telescope, located in West Texas at the McDonald Observatory. The HET operates with a fixed segmented primary and has a tracker, which moves the four-mirror corrector and prime focus instrument package to track the sidereal and non-sidereal motions of objects. We have completed a major multi-year upgrade of the HET that has substantially increased the pupil size to 10 meters and the field of view to 22 arcminutes by replacing the corrector, tracker, and prime focus instrument package. The new wide field HET will feed the revolutionary integral field spectrograph called VIRUS, in support of the Hobby-Eberly Telescope Dark Energy Experiment (HETDEX§), a new low resolution spectrograph (LRS2), an upgraded high resolution spectrograph (HRS2), and later the Habitable Zone Planet Finder (HPF). The upgrade is being commissioned and this paper discusses the completion of the installation, the commissioning process and the performance of the new HET.

  17. Development of a wide-field fluorescence imaging system for evaluation of wound re-epithelialization

    Science.gov (United States)

    Franco, Walfre; Gutierrez-Herrera, Enoch; Purschke, Martin; Wang, Ying; Tam, Josh; Anderson, R. Rox; Doukas, Apostolos

    2013-03-01

    Normal skin barrier function depends on having a viable epidermis, an epithelial layer formed by keratinocytes. The transparent epidermis, which is less than a 100 mum thick, is nearly impossible to see. Thus, the clinical evaluation of re-epithelialization is difficult, which hinders selecting appropriate therapy for promoting wound healing. An imaging system was developed to evaluate epithelialization by detecting endogenous fluorescence emissions of cellular proliferation over a wide field of view. A custom-made 295 nm ultraviolet (UV) light source was used for excitation. Detection was done by integrating a near-UV camera with sensitivity down to 300 nm, a 12 mm quartz lens with iris and focus lock for the UV regime, and a fluorescence bandpass filter with 340 nm center wavelength. To demonstrate that changes in fluorescence are related to cellular processes, the epithelialization of a skin substitute was monitored in vitro. The skin substitute or construct was made by embedding microscopic live human skin tissue columns, 1 mm in diameter and spaced 1 mm apart, in acellular porcine dermis. Fluorescence emissions clearly delineate the extent of lateral surface migration of keratinocytes and the total surface covered by the new epithelium. The fluorescence image of new epidermis spatially correlates with the corresponding color image. A simple, user-friendly way of imaging the presence of skin epithelium would improve wound care in civilian burns, ulcers and surgeries.

  18. Deriving the radial distances of wide coronal mass ejections from elongation measurements in the heliosphere – application to CME-CME interaction

    Directory of Open Access Journals (Sweden)

    I. I. Roussev

    2009-09-01

    Full Text Available We present general considerations regarding the derivation of the radial distances of coronal mass ejections (CMEs from elongation angle measurements such as those provided by SECCHI and SMEI, focusing on measurements in the Heliospheric Imager 2 (HI-2 field of view (i.e. past 0.3 AU. This study is based on a three-dimensional (3-D magneto-hydrodynamics (MHD simulation of two CMEs observed by SECCHI on 24–27 January 2007. Having a 3-D simulation with synthetic HI images, we are able to compare the two basic methods used to derive CME positions from elongation angles, the so-called "Point-P" and "Fixed-φ" approximations. We confirm, following similar works, that both methods, while valid in the most inner heliosphere, yield increasingly large errors in HI-2 field of view for fast and wide CMEs. Using a simple model of a CME as an expanding self-similar sphere, we derive an analytical relationship between elongation angles and radial distances for wide CMEs. This relationship is simply the harmonic mean of the "Point-P" and "Fixed-φ" approximations and it is aimed at complementing 3-D fitting of CMEs by cone models or flux rope shapes. It proves better at getting the kinematics of the simulated CME right when we compare the results of our line-of-sights to the MHD simulation. Based on this approximation, we re-analyze the J-maps (time-elongation maps in 26–27 January 2007 and present the first observational evidence that the merging of CMEs is associated with a momentum exchange from the faster ejection to the slower one due to the propagation of the shock wave associated with the fast eruption through the slow eruption.

  19. Study on the wide-angle Michelson interferometer with large air gap.

    Science.gov (United States)

    Gao, Haiyang; Tang, Yuanhe; Hua, Dengxin; Liu, Hanchen

    2011-10-10

    A wide-angle Michelson interferometer with large air gap is proposed to effectively reduce the size of the glass arms and constraint on material. It provides a novel and practical instrument for ground based wind measurement of the upper atmosphere. The field widening conditions for the large air gap are calculated in theory. For the five spectral lines of 557.7 nm, 630.0 nm, 732.0 nm, 834.6 nm, and 865.7 nm, the optimal results under ideal condition are obtained with air gaps of 1.0 cm, 1.5 cm, and 2.0 cm, respectively. With the fixed optical path difference (OPD) of 7.495 cm, three pairs of glass arms are optimized. The pair with length of 1.5 cm for air gap, 5.765 cm for H-ZF12, and 2.956 cm for H-ZLaF54, has better effect of field widening than the other two pairs and its OPD variation is only within 0.30 wavelengths at incident angle of 3°. For developing a more practical wide-angle Michelson interferometer, the H-K9L glass with size of 4.445 cm is employed as the arm material of solid interferometer. The experiment for field of view of 3° is designed and the data processing and analysis for 60 images show the agreement between experimental results and theoretical simulation. The OPD variations are only within 0.27 wavelengths for image edge. The feasibility and practicality of the wide-angle Michelson interferometer with large air gap is proved by means of theory and experiment. © 2011 Optical Society of America

  20. UNUSUALLY WIDE BINARIES: ARE THEY WIDE OR UNUSUAL?

    International Nuclear Information System (INIS)

    Kraus, Adam L.; Hillenbrand, Lynne A.

    2009-01-01

    We describe an astrometric and spectroscopic campaign to confirm the youth and association of a complete sample of candidate wide companions in Taurus and Upper Sco. Our survey found 15 new binary systems (three in Taurus and 12 in Upper Sco) with separations of 3''-30'' (500-5000 AU) among all of the known members with masses of 2.5-0.012 M sun . The total sample of 49 wide systems in these two regions conforms to only some expectations from field multiplicity surveys. Higher mass stars have a higher frequency of wide binary companions, and there is a marked paucity of wide binary systems near the substellar regime. However, the separation distribution appears to be log-flat, rather than declining as in the field, and the mass ratio distribution is more biased toward similar-mass companions than the initial mass function or the field G-dwarf distribution. The maximum separation also shows no evidence of a limit at ∼ sun . We attribute this result to the post-natal dynamical sculpting that occurs for most field systems; our binary systems will escape to the field intact, but most field stars are formed in denser clusters and undergo significant dynamical evolution. In summary, only wide binary systems with total masses ∼ sun appear to be 'unusually wide'.

  1. System Wide Information Management (SWIM)

    Science.gov (United States)

    Hritz, Mike; McGowan, Shirley; Ramos, Cal

    2004-01-01

    This viewgraph presentation lists questions regarding the implementation of System Wide Information Management (SWIM). Some of the questions concern policy issues and strategies, technology issues and strategies, or transition issues and strategies.

  2. Contact-free trans-pars-planar illumination enables snapshot fundus camera for nonmydriatic wide field photography.

    Science.gov (United States)

    Wang, Benquan; Toslak, Devrim; Alam, Minhaj Nur; Chan, R V Paul; Yao, Xincheng

    2018-06-08

    In conventional fundus photography, trans-pupillary illumination delivers illuminating light to the interior of the eye through the peripheral area of the pupil, and only the central part of the pupil can be used for collecting imaging light. Therefore, the field of view of conventional fundus cameras is limited, and pupil dilation is required for evaluating the retinal periphery which is frequently affected by diabetic retinopathy (DR), retinopathy of prematurity (ROP), and other chorioretinal conditions. We report here a nonmydriatic wide field fundus camera employing trans-pars-planar illumination which delivers illuminating light through the pars plana, an area outside of the pupil. Trans-pars-planar illumination frees the entire pupil for imaging purpose only, and thus wide field fundus photography can be readily achieved with less pupil dilation. For proof-of-concept testing, using all off-the-shelf components a prototype instrument that can achieve 90° fundus view coverage in single-shot fundus images, without the need of pharmacologic pupil dilation was demonstrated.

  3. Wide-field imaging of birefringent synovial fluid crystals using lens-free polarized microscopy for gout diagnosis

    Science.gov (United States)

    Zhang, Yibo; Lee, Seung Yoon Celine; Zhang, Yun; Furst, Daniel; Fitzgerald, John; Ozcan, Aydogan

    2016-06-01

    Gout is a form of crystal arthropathy where monosodium urate (MSU) crystals deposit and elicit inflammation in a joint. Diagnosis of gout relies on identification of MSU crystals under a compensated polarized light microscope (CPLM) in synovial fluid aspirated from the patient’s joint. The detection of MSU crystals by optical microscopy is enhanced by their birefringent properties. However, CPLM partially suffers from the high-cost and bulkiness of conventional lens-based microscopy, and its relatively small field-of-view (FOV) limits the efficiency and accuracy of gout diagnosis. Here we present a lens-free polarized microscope which adopts a novel differential and angle-mismatched polarizing optical design achieving wide-field and high-resolution holographic imaging of birefringent objects with a color contrast similar to that of a standard CPLM. The performance of this computational polarization microscope is validated by imaging MSU crystals made from a gout patient’s tophus and steroid crystals used as negative control. This lens-free polarized microscope, with its wide FOV (>20 mm2), cost-effectiveness and field-portability, can significantly improve the efficiency and accuracy of gout diagnosis, reduce costs, and can be deployed even at the point-of-care and in resource-limited clinical settings.

  4. Effects of spatial and spectral frequencies on wide-field functional imaging (wifi) characterization of preclinical breast cancer models

    Science.gov (United States)

    Moy, Austin; Kim, Jae G.; Lee, Eva Y. H. P.; Choi, Bernard

    2010-02-01

    A common strategy to study breast cancer is the use of the preclinical model. These models provide a physiologically relevant and controlled environment in which to study both response to novel treatments and the biology of the cancer. Preclinical models, including the spontaneous tumor model and mammary window chamber model, are very amenable to optical imaging and to this end, we have developed a wide-field functional imaging (WiFI) instrument that is perfectly suited to studying tumor metabolism in preclinical models. WiFI combines two optical imaging modalities, spatial frequency domain imaging (SFDI) and laser speckle imaging (LSI). Our current WiFI imaging protocol consists of multispectral imaging in the near infrared (650-980 nm) spectrum, over a wide (7 cm x 5 cm) field of view. Using SFDI, the spatially-resolved reflectance of sinusoidal patterns projected onto the tissue is assessed, and optical properties of the tissue are determined, which are then used to extract tissue chromophore concentrations in the form of oxy-, deoxy-, and total hemoglobin concentrations, and percentage of lipid and water. In the current study, we employ Monte Carlo simulations of SFDI light propagation in order to characterize the penetration depth of light in both the spontaneous tumor model and mammary window chamber model. Preliminary results suggest that different spatial frequency and wavelength combinations have different penetration depths, suggesting the potential depth sectioning capability of the SFDI component of WiFI.

  5. World-wide environmental problems

    International Nuclear Information System (INIS)

    Wohlers, H.C.

    1975-01-01

    Man and the physical and natural resources necessary to support him in a civilized society are on a collision course. It is simple to say that man cannot continue to grow in number at an ever-increasing rate without a destructive effect upon the environment. Positive scientific proof for this impending calamity is not now available, yet many indications--sometimes physical and sometimes natural--point toward major world-wide environmental troubles in the near future. A number of environmental problems are described, particularly as they relate to the total world system. A computer model simulating future world-wide environmental trends from 1900 to 2100 A.D. is evaluated and suggested as a major tool for data-gathering purposes to determine the extent of world-wide environmental problems. It is suggested that scientists take an active role in the study of the environment, particularly in relation to man's future on earth

  6. Wide gap semiconductor microwave devices

    International Nuclear Information System (INIS)

    Buniatyan, V V; Aroutiounian, V M

    2007-01-01

    A review of properties of wide gap semiconductor materials such as diamond, diamond-like carbon films, SiC, GaP, GaN and AlGaN/GaN that are relevant to electronic, optoelectronic and microwave applications is presented. We discuss the latest situation and perspectives based on experimental and theoretical results obtained for wide gap semiconductor devices. Parameters are taken from the literature and from some of our theoretical works. The correspondence between theoretical results and parameters of devices is critically analysed. (review article)

  7. Wide-field fluorescent microscopy and fluorescent imaging flow cytometry on a cell-phone.

    Science.gov (United States)

    Zhu, Hongying; Ozcan, Aydogan

    2013-04-11

    Fluorescent microscopy and flow cytometry are widely used tools in biomedical research and clinical diagnosis. However these devices are in general relatively bulky and costly, making them less effective in the resource limited settings. To potentially address these limitations, we have recently demonstrated the integration of wide-field fluorescent microscopy and imaging flow cytometry tools on cell-phones using compact, light-weight, and cost-effective opto-fluidic attachments. In our flow cytometry design, fluorescently labeled cells are flushed through a microfluidic channel that is positioned above the existing cell-phone camera unit. Battery powered light-emitting diodes (LEDs) are butt-coupled to the side of this microfluidic chip, which effectively acts as a multi-mode slab waveguide, where the excitation light is guided to uniformly excite the fluorescent targets. The cell-phone camera records a time lapse movie of the fluorescent cells flowing through the microfluidic channel, where the digital frames of this movie are processed to count the number of the labeled cells within the target solution of interest. Using a similar opto-fluidic design, we can also image these fluorescently labeled cells in static mode by e.g. sandwiching the fluorescent particles between two glass slides and capturing their fluorescent images using the cell-phone camera, which can achieve a spatial resolution of e.g. - 10 μm over a very large field-of-view of - 81 mm(2). This cell-phone based fluorescent imaging flow cytometry and microscopy platform might be useful especially in resource limited settings, for e.g. counting of CD4+ T cells toward monitoring of HIV+ patients or for detection of water-borne parasites in drinking water.

  8. Cycloid scanning for wide field optical coherence tomography endomicroscopy and angiography in vivo

    Science.gov (United States)

    Liang, Kaicheng; Wang, Zhao; Ahsen, Osman O.; Lee, Hsiang-Chieh; Potsaid, Benjamin M.; Jayaraman, Vijaysekhar; Cable, Alex; Mashimo, Hiroshi; Li, Xingde; Fujimoto, James G.

    2018-01-01

    Devices that perform wide field-of-view (FOV) precision optical scanning are important for endoscopic assessment and diagnosis of luminal organ disease such as in gastroenterology. Optical scanning for in vivo endoscopic imaging has traditionally relied on one or more proximal mechanical actuators, limiting scan accuracy and imaging speed. There is a need for rapid and precise two-dimensional (2D) microscanning technologies to enable the translation of benchtop scanning microscopies to in vivo endoscopic imaging. We demonstrate a new cycloid scanner in a tethered capsule for ultrahigh speed, side-viewing optical coherence tomography (OCT) endomicroscopy in vivo. The cycloid capsule incorporates two scanners: a piezoelectrically actuated resonant fiber scanner to perform a precision, small FOV, fast scan and a micromotor scanner to perform a wide FOV, slow scan. Together these scanners distally scan the beam circumferentially in a 2D cycloid pattern, generating an unwrapped 1 mm × 38 mm strip FOV. Sequential strip volumes can be acquired with proximal pullback to image centimeter-long regions. Using ultrahigh speed 1.3 μm wavelength swept-source OCT at a 1.17 MHz axial scan rate, we imaged the human rectum at 3 volumes/s. Each OCT strip volume had 166 × 2322 axial scans with 8.5 μm axial and 30 μm transverse resolution. We further demonstrate OCT angiography at 0.5 volumes/s, producing volumetric images of vasculature. In addition to OCT applications, cycloid scanning promises to enable precision 2D optical scanning for other imaging modalities, including fluorescence confocal and nonlinear microscopy. PMID:29682598

  9. Speckle correlation resolution enhancement of wide-field fluorescence imaging (Conference Presentation)

    Science.gov (United States)

    Yilmaz, Hasan

    2016-03-01

    Structured illumination enables high-resolution fluorescence imaging of nanostructures [1]. We demonstrate a new high-resolution fluorescence imaging method that uses a scattering layer with a high-index substrate as a solid immersion lens [2]. Random scattering of coherent light enables a speckle pattern with a very fine structure that illuminates the fluorescent nanospheres on the back surface of the high-index substrate. The speckle pattern is raster-scanned over the fluorescent nanospheres using a speckle correlation effect known as the optical memory effect. A series of standard-resolution fluorescence images per each speckle pattern displacement are recorded by an electron-multiplying CCD camera using a commercial microscope objective. We have developed a new phase-retrieval algorithm to reconstruct a high-resolution, wide-field image from several standard-resolution wide-field images. We have introduced phase information of Fourier components of standard-resolution images as a new constraint in our algorithm which discards ambiguities therefore ensures convergence to a unique solution. We demonstrate two-dimensional fluorescence images of a collection of nanospheres with a deconvolved Abbe resolution of 116 nm and a field of view of 10 µm × 10 µm. Our method is robust against optical aberrations and stage drifts, therefore excellent for imaging nanostructures under ambient conditions. [1] M. G. L. Gustafsson, J. Microsc. 198, 82-87 (2000). [2] H. Yilmaz, E. G. van Putten, J. Bertolotti, A. Lagendijk, W. L. Vos, and A. P. Mosk, Optica 2, 424-429 (2015).

  10. World Wide Web Homepage Design.

    Science.gov (United States)

    Tillman, Michael L.

    This paper examines hypermedia design and draws conclusions about how educational research and theory applies to various aspects of World Wide Web (WWW) homepage design. "Hypermedia" is defined as any collection of information which may be textual, graphical, visual, or auditory in nature and which may be accessed via a nonlinear route.…

  11. The World Wide Web Revisited

    Science.gov (United States)

    Owston, Ron

    2007-01-01

    Nearly a decade ago the author wrote in one of the first widely-cited academic articles, Educational Researcher, about the educational role of the web. He argued that educators must be able to demonstrate that the web (1) can increase access to learning, (2) must not result in higher costs for learning, and (3) can lead to improved learning. These…

  12. Wide Bandgap Extrinsic Photoconductive Switches

    Energy Technology Data Exchange (ETDEWEB)

    Sullivan, James S. [State Univ. of New York (SUNY), Plattsburgh, NY (United States); Univ. of California, Davis, CA (United States)

    2012-01-20

    Photoconductive semiconductor switches (PCSS) have been investigated since the late 1970s. Some devices have been developed that withstand tens of kilovolts and others that switch hundreds of amperes. However, no single device has been developed that can reliably withstand both high voltage and switch high current. Yet, photoconductive switches still hold the promise of reliable high voltage and high current operation with subnanosecond risetimes. Particularly since good quality, bulk, single crystal, wide bandgap semiconductor materials have recently become available. In this chapter we will review the basic operation of PCSS devices, status of PCSS devices and properties of the wide bandgap semiconductors 4H-SiC, 6H-SiC and 2H-GaN.

  13. Wide range neutron flux monitor

    International Nuclear Information System (INIS)

    Endo, Yorimasa; Fukushima, Toshiki.

    1983-01-01

    Purpose: To provide a wide range neutron-flux monitor adapted such that the flux monitoring function and alarming function can automatically by shifted from pulse counting system to cambel method system. Constitution: A wide range neutron-flux monitor comprises (la) pulse counting system and (lb) cambel-method system for inputting detection signals from neutron detectors and separating them into signals for the pulse measuring system and the cambel measuring system, (2) overlap detection and calculation circuit for detecting the existence of the overlap of two output signals from the (la) and (lb) systems, and (3) trip circuit for judging the abnormal state of neutron detectors upon input of the detection signals. (Seki, T.)

  14. NCenter wide band neutrino beam

    International Nuclear Information System (INIS)

    Stutte, L.G.

    1985-01-01

    This memo describes the physical properties of the currently operating N-Center wide band neutrino beam---commonly called the triplet train, following a past tradition of a triplet lens configuration. In reality, in order to gain a larger momentum acceptance and to minimize the angular divergence of the beam, a quadruplet beam (4 lenses) employing point-to-parallel optics at a central momentum of 300 GeV was built. 6 refs., 13 figs., 1 tab

  15. Wide range neutron detection system

    International Nuclear Information System (INIS)

    Todt, W.H. Sr.

    1978-01-01

    A neutron detection system for reactor control is described which is operable over a wide range of neutron flux levels. The system includes a fission type ionization chamber neutron detector, means for gamma and alpha signal compensation, and means for operating the neutron detector in the pulse counting mode for low neutron flux levels, and in the direct current mode for high neutron flux levels

  16. Wide and High Additive Manufacturing

    Energy Technology Data Exchange (ETDEWEB)

    Post, Brian K. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Roschli, Alex C. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States)

    2017-03-01

    The goal of this project is to develop and demonstrate the enabling technologies for Wide and High Additive Manufacturing (WHAM). WHAM will open up new areas of U.S. manufacturing for very large tooling in support of the transportation and energy industries, significantly reducing cost and lead time. As with Big Area Additive Manufacturing (BAAM), the initial focus is on the deposition of composite materials.

  17. Wide Bandgap Extrinsic Photoconductive Switches

    Energy Technology Data Exchange (ETDEWEB)

    Sullivan, James S. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States)

    2013-07-03

    Semi-insulating Gallium Nitride, 4H and 6H Silicon Carbide are attractive materials for compact, high voltage, extrinsic, photoconductive switches due to their wide bandgap, high dark resistance, high critical electric field strength and high electron saturation velocity. These wide bandgap semiconductors are made semi-insulating by the addition of vanadium (4H and 6HSiC) and iron (2H-GaN) impurities that form deep acceptors. These deep acceptors trap electrons donated from shallow donor impurities. The electrons can be optically excited from these deep acceptor levels into the conduction band to transition the wide bandgap semiconductor materials from a semi-insulating to a conducting state. Extrinsic photoconductive switches with opposing electrodes have been constructed using vanadium compensated 6H-SiC and iron compensated 2H-GaN. These extrinsic photoconductive switches were tested at high voltage and high power to determine if they could be successfully used as the closing switch in compact medical accelerators.

  18. World wide developments in shortwall and wide web mining techniques

    Energy Technology Data Exchange (ETDEWEB)

    Pollard, T

    1975-11-01

    The paper describes the progress to date with continuous pillar extraction, and how the typical longwall powered support has been modified to be both strong enough and stable enough to provide roof support for very wide webs. It also describes the operating systems which have been specially designed. The next stages of development are discussed, particularly the provision of continuous conveyor haulage in place of the present-day shuttle car. The author suggests that marrying American coal-getting technology and British roof support technology might increase productivity.

  19. SeaWiFS technical report series. Volume 11: Analysis of selected orbit propagation models for the SeaWiFS mission

    Science.gov (United States)

    Patt, Frederick S.; Hoisington, Charles M.; Gregg, Watson W.; Coronado, Patrick L.; Hooker, Stanford B. (Editor); Firestone, Elaine R. (Editor); Indest, A. W. (Editor)

    1993-01-01

    An analysis of orbit propagation models was performed by the Mission Operations element of the Sea-viewing Wide Field-of-View Sensor (SeaWiFS) Project, which has overall responsibility for the instrument scheduling. The orbit propagators selected for this analysis are widely available general perturbations models. The analysis includes both absolute accuracy determination and comparisons of different versions of the models. The results show that all of the models tested meet accuracy requirements for scheduling and data acquisition purposes. For internal Project use the SGP4 propagator, developed by the North American Air Defense (NORAD) Command, has been selected. This model includes atmospheric drag effects and, therefore, provides better accuracy. For High Resolution Picture Transmission (HRPT) ground stations, which have less stringent accuracy requirements, the publicly available Brouwer-Lyddane models are recommended. The SeaWiFS Project will make available portable source code for a version of this model developed by the Data Capture Facility (DCF).

  20. A generalized measurement equation and van Cittert-Zernike theorem for wide-field radio astronomical interferometry

    Science.gov (United States)

    Carozzi, T. D.; Woan, G.

    2009-05-01

    We derive a generalized van Cittert-Zernike (vC-Z) theorem for radio astronomy that is valid for partially polarized sources over an arbitrarily wide field of view (FoV). The classical vC-Z theorem is the theoretical foundation of radio astronomical interferometry, and its application is the basis of interferometric imaging. Existing generalized vC-Z theorems in radio astronomy assume, however, either paraxiality (narrow FoV) or scalar (unpolarized) sources. Our theorem uses neither of these assumptions, which are seldom fulfiled in practice in radio astronomy, and treats the full electromagnetic field. To handle wide, partially polarized fields, we extend the two-dimensional (2D) electric field (Jones vector) formalism of the standard `Measurement Equation' (ME) of radio astronomical interferometry to the full three-dimensional (3D) formalism developed in optical coherence theory. The resulting vC-Z theorem enables full-sky imaging in a single telescope pointing, and imaging based not only on standard dual-polarized interferometers (that measure 2D electric fields) but also electric tripoles and electromagnetic vector-sensor interferometers. We show that the standard 2D ME is easily obtained from our formalism in the case of dual-polarized antenna element interferometers. We also exploit an extended 2D ME to determine that dual-polarized interferometers can have polarimetric aberrations at the edges of a wide FoV. Our vC-Z theorem is particularly relevant to proposed, and recently developed, wide FoV interferometers such as Low Frequency Array (LOFAR) and Square Kilometer Array (SKA), for which direction-dependent effects will be important.

  1. SAAO's new robotic telescope and WiNCam (Wide-field Nasmyth Camera)

    Science.gov (United States)

    Worters, Hannah L.; O'Connor, James E.; Carter, David B.; Loubser, Egan; Fourie, Pieter A.; Sickafoose, Amanda; Swanevelder, Pieter

    2016-08-01

    The South African Astronomical Observatory (SAAO) is designing and manufacturing a wide-field camera for use on two of its telescopes. The initial concept was of a Prime focus camera for the 74" telescope, an equatorial design made by Grubb Parsons, where it would employ a 61mmx61mm detector to cover a 23 arcmin diameter field of view. However, while in the design phase, SAAO embarked on the process of acquiring a bespoke 1-metre robotic alt-az telescope with a 43 arcmin field of view, which needs a homegrown instrument suite. The Prime focus camera design was thus adapted for use on either telescope, increasing the detector size to 92mmx92mm. Since the camera will be mounted on the Nasmyth port of the new telescope, it was dubbed WiNCam (Wide-field Nasmyth Camera). This paper describes both WiNCam and the new telescope. Producing an instrument that can be swapped between two very different telescopes poses some unique challenges. At the Nasmyth port of the alt-az telescope there is ample circumferential space, while on the 74 inch the available envelope is constrained by the optical footprint of the secondary, if further obscuration is to be avoided. This forces the design into a cylindrical volume of 600mm diameter x 250mm height. The back focal distance is tightly constrained on the new telescope, shoehorning the shutter, filter unit, guider mechanism, a 10mm thick window and a tip/tilt mechanism for the detector into 100mm depth. The iris shutter and filter wheel planned for prime focus could no longer be accommodated. Instead, a compact shutter with a thickness of less than 20mm has been designed in-house, using a sliding curtain mechanism to cover an aperture of 125mmx125mm, while the filter wheel has been replaced with 2 peripheral filter cartridges (6 filters each) and a gripper to move a filter into the beam. We intend using through-vacuum wall PCB technology across the cryostat vacuum interface, instead of traditional hermetic connector-based wiring. This

  2. Wide-Field Optic for Autonomous Acquisition of Laser Link

    Science.gov (United States)

    Page, Norman A.; Charles, Jeffrey R.; Biswas, Abhijit

    2011-01-01

    An innovation reported in Two-Camera Acquisition and Tracking of a Flying Target, NASA Tech Briefs, Vol. 32, No. 8 (August 2008), p. 20, used a commercial fish-eye lens and an electronic imaging camera for initially locating objects with subsequent handover to an actuated narrow-field camera. But this operated against a dark-sky background. An improved solution involves an optical design based on custom optical components for the wide-field optical system that directly addresses the key limitations in acquiring a laser signal from a moving source such as an aircraft or a spacecraft. The first challenge was to increase the light collection entrance aperture diameter, which was approximately 1 mm in the first prototype. The new design presented here increases this entrance aperture diameter to 4.2 mm, which is equivalent to a more than 16 times larger collection area. One of the trades made in realizing this improvement was to restrict the field-of-view to +80 deg. elevation and 360 azimuth. This trade stems from practical considerations where laser beam propagation over the excessively high air mass, which is in the line of sight (LOS) at low elevation angles, results in vulnerability to severe atmospheric turbulence and attenuation. An additional benefit of the new design is that the large entrance aperture is maintained even at large off-axis angles when the optic is pointed at zenith. The second critical limitation for implementing spectral filtering in the design was tackled by collimating the light prior to focusing it onto the focal plane. This allows the placement of the narrow spectral filter in the collimated portion of the beam. For the narrow band spectral filter to function properly, it is necessary to adequately control the range of incident angles at which received light intercepts the filter. When this angle is restricted via collimation, narrower spectral filtering can be implemented. The collimated beam (and the filter) must be relatively large to

  3. Wide-range voltage modulation

    International Nuclear Information System (INIS)

    Rust, K.R.; Wilson, J.M.

    1992-06-01

    The Superconducting Super Collider's Medium Energy Booster Abort (MEBA) kicker modulator will supply a current pulse to the abort magnets which deflect the proton beam from the MEB ring into a designated beam stop. The abort kicker will be used extensively during testing of the Low Energy Booster (LEB) and the MEB rings. When the Collider is in full operation, the MEBA kicker modulator will abort the MEB beam in the event of a malfunction during the filling process. The modulator must generate a 14-μs wide pulse with a rise time of less than 1 μs, including the delay and jitter times. It must also be able to deliver a current pulse to the magnet proportional to the beam energy at any time during ramp-up of the accelerator. Tracking the beam energy, which increases from 12 GeV at injection to 200 GeV at extraction, requires the modulator to operate over a wide range of voltages (4 kV to 80 kV). A vacuum spark gap and a thyratron have been chosen for test and evaluation as candidate switches for the abort modulator. Modulator design, switching time delay, jitter and pre-fire data are presented

  4. 1-Million droplet array with wide-field fluorescence imaging for digital PCR.

    Science.gov (United States)

    Hatch, Andrew C; Fisher, Jeffrey S; Tovar, Armando R; Hsieh, Albert T; Lin, Robert; Pentoney, Stephen L; Yang, David L; Lee, Abraham P

    2011-11-21

    Digital droplet reactors are useful as chemical and biological containers to discretize reagents into picolitre or nanolitre volumes for analysis of single cells, organisms, or molecules. However, most DNA based assays require processing of samples on the order of tens of microlitres and contain as few as one to as many as millions of fragments to be detected. Presented in this work is a droplet microfluidic platform and fluorescence imaging setup designed to better meet the needs of the high-throughput and high-dynamic-range by integrating multiple high-throughput droplet processing schemes on the chip. The design is capable of generating over 1-million, monodisperse, 50 picolitre droplets in 2-7 minutes that then self-assemble into high density 3-dimensional sphere packing configurations in a large viewing chamber for visualization and analysis. This device then undergoes on-chip polymerase chain reaction (PCR) amplification and fluorescence detection to digitally quantify the sample's nucleic acid contents. Wide-field fluorescence images are captured using a low cost 21-megapixel digital camera and macro-lens with an 8-12 cm(2) field-of-view at 1× to 0.85× magnification, respectively. We demonstrate both end-point and real-time imaging ability to perform on-chip quantitative digital PCR analysis of the entire droplet array. Compared to previous work, this highly integrated design yields a 100-fold increase in the number of on-chip digitized reactors with simultaneous fluorescence imaging for digital PCR based assays.

  5. Commissioning and quality control of a dedicated wide bore 3T MRI simulator for radiotherapy planning

    Directory of Open Access Journals (Sweden)

    Aitang Xing

    2016-06-01

    Full Text Available Purpose: The purpose of this paper is to describe a practical approach to commissioning and quality assurance (QA of a dedicated wide-bore 3 Tesla (3T magnetic resonance imaging (MRI scanner for radiotherapy planning.Methods: A comprehensive commissioning protocol focusing on radiotherapy (RT specific requirements was developed and performed. RT specific tests included: uniformity characteristics of radio-frequency (RF coil, couch top attenuation, geometric distortion, laser and couch movement and an end-to-end radiotherapy treatment planning test. General tests for overall system performance and safety measurements were also performed.Results: The use of pre-scan based intensity correction increased the uniformity from 61.7% to 97% (body flexible coil, from 50% to 90% (large flexible coil and from 51% to 98% (small flexible coil. RT flat top couch decreased signal-to-noise ratio (SNR by an average of 42%. The mean and maximum geometric distortion was found to be 1.25 mm and 4.08 mm for three dimensional (3D corrected image acquisition, 2.07 mm and 7.88 mm for two dimensional (2D corrected image acquisition over 500 mm × 375 mm × 252 mm field of view (FOV. The accuracy of the laser and couch movement was less than ±1 mm. The standard deviation of registration parameters for the end-to-end test was less than 0.41 mm. An on-going QA program was developed to monitor the system’s performance.Conclusion: A number of RT specific tests have been described for commissioning and subsequent performance monitoring of a dedicated MRI simulator (MRI-Sim. These tests have been important in establishing and maintaining its operation for RT planning.

  6. The Brazilian wide field imaging camera (WFI) for the China/Brazil earth resources satellite: CBERS 3 and 4

    Science.gov (United States)

    Scaduto, L. C. N.; Carvalho, E. G.; Modugno, R. G.; Cartolano, R.; Evangelista, S. H.; Segoria, D.; Santos, A. G.; Stefani, M. A.; Castro Neto, J. C.

    2017-11-01

    The purpose of this paper is to present the optical system developed for the Wide Field imaging Camera - WFI that will be integrated to the CBERS 3 and 4 satellites (China Brazil Earth resources Satellite). This camera will be used for remote sensing of the Earth and it is aimed to work at an altitude of 778 km. The optical system is designed for four spectral bands covering the range of wavelengths from blue to near infrared and its field of view is +/-28.63°, which covers 866 km, with a ground resolution of 64 m at nadir. WFI has been developed through a consortium formed by Opto Electrônica S. A. and Equatorial Sistemas. In particular, we will present the optical analysis based on the Modulation Transfer Function (MTF) obtained during the Engineering Model phase (EM) and the optical tests performed to evaluate the requirements. Measurements of the optical system MTF have been performed using an interferometer at the wavelength of 632.8nm and global MTF tests (including the CCD and signal processing electronic) have been performed by using a collimator with a slit target. The obtained results showed that the performance of the optical system meets the requirements of project.

  7. A hands-free region-of-interest selection interface for solo surgery with a wide-angle endoscope: preclinical proof of concept.

    Science.gov (United States)

    Jung, Kyunghwa; Choi, Hyunseok; Hong, Hanpyo; Adikrishna, Arnold; Jeon, In-Ho; Hong, Jaesung

    2017-02-01

    A hands-free region-of-interest (ROI) selection interface is proposed for solo surgery using a wide-angle endoscope. A wide-angle endoscope provides images with a larger field of view than a conventional endoscope. With an appropriate selection interface for a ROI, surgeons can also obtain a detailed local view as if they moved a conventional endoscope in a specific position and direction. To manipulate the endoscope without releasing the surgical instrument in hand, a mini-camera is attached to the instrument, and the images taken by the attached camera are analyzed. When a surgeon moves the instrument, the instrument orientation is calculated by an image processing. Surgeons can select the ROI with this instrument movement after switching from 'task mode' to 'selection mode.' The accelerated KAZE algorithm is used to track the features of the camera images once the instrument is moved. Both the wide-angle and detailed local views are displayed simultaneously, and a surgeon can move the local view area by moving the mini-camera attached to the surgical instrument. Local view selection for a solo surgery was performed without releasing the instrument. The accuracy of camera pose estimation was not significantly different between camera resolutions, but it was significantly different between background camera images with different numbers of features (P solo surgeries without a camera assistant.

  8. Improving the wide resonance approximation

    International Nuclear Information System (INIS)

    Aboustta, Mohamed A.; Martinez, Aquilino S.

    1999-01-01

    A resonance is considered wide if its practical width, in energy, exceeds the average energy loss per collision, E(1-α A )/2, of the absorbing material. When the mass number, A, is taken infinite, the scattering produces only a change in the direction of motion of the neutron and not in its energy. Based on this assumption, the integral in the slowing-down equation describing the contribution of the resonant absorber is evaluated by taking its limit when α A →1. This work questions the necessity to take such a limit and shows that it is still possible to obtain a simple and more accurate expression for the integral without taking such limit

  9. Improving the wide resonance approximation

    Energy Technology Data Exchange (ETDEWEB)

    Aboustta, Mohamed A.; Martinez, Aquilino S

    1999-03-01

    A resonance is considered wide if its practical width, in energy, exceeds the average energy loss per collision, E(1-{alpha}{sub A})/2, of the absorbing material. When the mass number, A, is taken infinite, the scattering produces only a change in the direction of motion of the neutron and not in its energy. Based on this assumption, the integral in the slowing-down equation describing the contribution of the resonant absorber is evaluated by taking its limit when {alpha}{sub A}{yields}1. This work questions the necessity to take such a limit and shows that it is still possible to obtain a simple and more accurate expression for the integral without taking such limit.

  10. Enterprise wide transparent information access

    International Nuclear Information System (INIS)

    Brown, J.

    1995-05-01

    The information management needs of the Department of Energy (DOE) represents a fertile domain for the development of highly sophisticated yet intuitive enterprise-wide computing solutions. These solutions must support business operations, research agendas, technology development efforts, decision support, and other application areas with a user base ranging from technical staff to the highest levels of management. One area of primary interest is in the Environmental Restoration and Waste Management Branch of DOE. In this arena, the issue of tracking and managing nuclear waste related to the long legacy of prior defense production and research programs is one of high visibility and great concern. The Tank Waste Information Network System (TWINS) application has been created by the Pacific Northwest Laboratory (PNL) for the DOE to assist in managing and accessing the information related to this mission. The TWINS solution addresses many of the technical issues faced by other efforts to provide integrated information access to a wide variety of stakeholders. TWINS provides secure transparent access to distributed heterogeneous multimedia information sources from around the DOE complex. The users interact with the information through a consistent user interface that presents the desired data in a common format regardless of the structure of the source information. The solutions developed by the TWINS project represent an integration of several technologies and products that can be applied to other mission areas within DOE and other government agencies. These solutions are now being applied to public and private sector problem domains as well. The successful integration and inter-operation of both commercial and custom modules into a flexible and extensible information architecture will help ensure that new problems facing DOE and other clients can be addressed more rapidly in the future by re-use of existing tools and techniques proven viable through the TWINS efforts

  11. Ultra-large field-of-view two-photon microscopy

    OpenAIRE

    Tsai, Philbert S.; Mateo, Celine; Field, Jeffrey J.; Schaffer, Chris B.; Anderson, Matthew E.; Kleinfeld, David

    2015-01-01

    We present a two-photon microscope that images the full extent of murine cortex with an objective-limited spatial resolution across an 8 mm by 10 mm field. The lateral resolution is approximately 1 µm and the maximum scan speed is 5 mm/ms. The scan pathway employs large diameter compound lenses to minimize aberrations and performs near theoretical limits. We demonstrate the special utility of the microscope by recording resting-state vasomotion across both hemispheres of the murine brain thro...

  12. Spiral CT of the pancreas. The value of small field-of-view targeted reconstruction

    International Nuclear Information System (INIS)

    Nishiharu, T.; Yamashita, Y.; Ogata, I.; Sumi, S.; Mitsuzaki, K.; Takahashi, M.

    1998-01-01

    Purpose: To compare the value of a retrospective targeted high-resolution spiral CT to the standard reconstruction technique in the assessment of pancreatic diseases. Material and methods: Spiral CT pancreatic images of a standard-size reconstruction protocol were compared prospectively with those of a retrospective targeted high-spatial-resolution reconstruction protocol in 30 patients. Prior to clinical evaluation, a phantom study was performed to evaluate the spatial resolution and signal-to-noise ratio of both protocols. Results: The high-resolution protocol achieved a good signal-to-noise ratio with acceptable spatial resolution. Phantom studies revealed increased image noise (+17%) with an increase in spatial resolution (+100%). In patients studied with the high-resolution protocol, the increase in noise was not significant but there was a marked improvement in the definition of small details. Conclusion: Images obtained with a targeted high-spatial-resolution reconstruction protocol showed superior lesion definition and vascular opacification compared with those obtained with a standard-size reconstruction protocol. This technique may have potential in the evaluation of small pancreatic abnormalities. (orig.)

  13. Study of shape evaluation for mask and silicon using large field of view

    Science.gov (United States)

    Matsuoka, Ryoichi; Mito, Hiroaki; Shinoda, Shinichi; Toyoda, Yasutaka

    2010-09-01

    We have developed a highly integrated method of mask and silicon metrology. The aim of this integration is evaluating the performance of the silicon corresponding to Hotspot on a mask. It can use the mask shape of a large field, besides. The method adopts a metrology management system based on DBM (Design Based Metrology). This is the high accurate contouring created by an edge detection algorithm used in mask CD-SEM and silicon CD-SEM. Currently, as semiconductor manufacture moves towards even smaller feature size, this necessitates more aggressive optical proximity correction (OPC) to drive the super-resolution technology (RET). In other words, there is a trade-off between highly precise RET and mask manufacture, and this has a big impact on the semiconductor market that centers on the mask business. As an optimal solution to these issues, we provide a DFM solution that extracts 2-dimensional data for a more realistic and error-free simulation by reproducing accurately the contour of the actual mask, in addition to the simulation results from the mask data. On the other hand, there is roughness in the silicon form made from a mass-production line. Moreover, there is variation in the silicon form. For this reason, quantification of silicon form is important, in order to estimate the performance of a pattern. In order to quantify, the same form is equalized in two dimensions. And the method of evaluating based on the form is popular. In this study, we conducted experiments for averaging method of the pattern (Measurement Based Contouring) as two-dimensional mask and silicon evaluation technique. That is, observation of the identical position of a mask and a silicon was considered. The result proved its detection accuracy and reliability of variability on two-dimensional pattern (mask and silicon) and is adaptable to following fields of mask quality management. •Discrimination of nuisance defects for fine pattern. •Determination of two-dimensional variability of pattern. •Verification of the performance of the pattern of various kinds of Hotspots. In this report, we introduce the experimental results and the application. We expect that the mask measurement and the shape control on mask production will make a huge contribution to mask yield-enhancement and that the DFM solution for mask quality control process will become much more important technology than ever. It is very important to observe the form of the same location of Design, Mask, and Silicon in such a viewpoint. And we report it about algorithm of the image composition in Large Field.

  14. Multiband CCD Image Compression for Space Camera with Large Field of View

    Directory of Open Access Journals (Sweden)

    Jin Li

    2014-01-01

    Full Text Available Space multiband CCD camera compression encoder requires low-complexity, high-robustness, and high-performance because of its captured images information being very precious and also because it is usually working on the satellite where the resources, such as power, memory, and processing capacity, are limited. However, the traditional compression approaches, such as JPEG2000, 3D transforms, and PCA, have the high-complexity. The Consultative Committee for Space Data Systems-Image Data Compression (CCSDS-IDC algorithm decreases the average PSNR by 2 dB compared with JPEG2000. In this paper, we proposed a low-complexity compression algorithm based on deep coupling algorithm among posttransform in wavelet domain, compressive sensing, and distributed source coding. In our algorithm, we integrate three low-complexity and high-performance approaches in a deeply coupled manner to remove the spatial redundant, spectral redundant, and bit information redundancy. Experimental results on multiband CCD images show that the proposed algorithm significantly outperforms the traditional approaches.

  15. Electronically Steerable Antennas with Panoramic Scan Field of View, Phase I

    Data.gov (United States)

    National Aeronautics and Space Administration — Electronically steerable antennas are key to effective radio transmission at millimeter-wave frequencies. To enable communication with rovers, robots, EVA...

  16. Automated bone segmentation from large field of view 3D MR images of the hip joint

    International Nuclear Information System (INIS)

    Xia, Ying; Fripp, Jurgen; Chandra, Shekhar S; Schwarz, Raphael; Engstrom, Craig; Crozier, Stuart

    2013-01-01

    Accurate bone segmentation in the hip joint region from magnetic resonance (MR) images can provide quantitative data for examining pathoanatomical conditions such as femoroacetabular impingement through to varying stages of osteoarthritis to monitor bone and associated cartilage morphometry. We evaluate two state-of-the-art methods (multi-atlas and active shape model (ASM) approaches) on bilateral MR images for automatic 3D bone segmentation in the hip region (proximal femur and innominate bone). Bilateral MR images of the hip joints were acquired at 3T from 30 volunteers. Image sequences included water-excitation dual echo stead state (FOV 38.6 × 24.1 cm, matrix 576 × 360, thickness 0.61 mm) in all subjects and multi-echo data image combination (FOV 37.6 × 23.5 cm, matrix 576 × 360, thickness 0.70 mm) for a subset of eight subjects. Following manual segmentation of femoral (head–neck, proximal-shaft) and innominate (ilium+ischium+pubis) bone, automated bone segmentation proceeded via two approaches: (1) multi-atlas segmentation incorporating non-rigid registration and (2) an advanced ASM-based scheme. Mean inter- and intra-rater reliability Dice's similarity coefficients (DSC) for manual segmentation of femoral and innominate bone were (0.970, 0.963) and (0.971, 0.965). Compared with manual data, mean DSC values for femoral and innominate bone volumes using automated multi-atlas and ASM-based methods were (0.950, 0.922) and (0.946, 0.917), respectively. Both approaches delivered accurate (high DSC values) segmentation results; notably, ASM data were generated in substantially less computational time (12 min versus 10 h). Both automated algorithms provided accurate 3D bone volumetric descriptions for MR-based measures in the hip region. The highly computational efficient ASM-based approach is more likely suitable for future clinical applications such as extracting bone–cartilage interfaces for potential cartilage segmentation. (paper)

  17. Automated bone segmentation from large field of view 3D MR images of the hip joint

    Science.gov (United States)

    Xia, Ying; Fripp, Jurgen; Chandra, Shekhar S.; Schwarz, Raphael; Engstrom, Craig; Crozier, Stuart

    2013-10-01

    Accurate bone segmentation in the hip joint region from magnetic resonance (MR) images can provide quantitative data for examining pathoanatomical conditions such as femoroacetabular impingement through to varying stages of osteoarthritis to monitor bone and associated cartilage morphometry. We evaluate two state-of-the-art methods (multi-atlas and active shape model (ASM) approaches) on bilateral MR images for automatic 3D bone segmentation in the hip region (proximal femur and innominate bone). Bilateral MR images of the hip joints were acquired at 3T from 30 volunteers. Image sequences included water-excitation dual echo stead state (FOV 38.6 × 24.1 cm, matrix 576 × 360, thickness 0.61 mm) in all subjects and multi-echo data image combination (FOV 37.6 × 23.5 cm, matrix 576 × 360, thickness 0.70 mm) for a subset of eight subjects. Following manual segmentation of femoral (head-neck, proximal-shaft) and innominate (ilium+ischium+pubis) bone, automated bone segmentation proceeded via two approaches: (1) multi-atlas segmentation incorporating non-rigid registration and (2) an advanced ASM-based scheme. Mean inter- and intra-rater reliability Dice's similarity coefficients (DSC) for manual segmentation of femoral and innominate bone were (0.970, 0.963) and (0.971, 0.965). Compared with manual data, mean DSC values for femoral and innominate bone volumes using automated multi-atlas and ASM-based methods were (0.950, 0.922) and (0.946, 0.917), respectively. Both approaches delivered accurate (high DSC values) segmentation results; notably, ASM data were generated in substantially less computational time (12 min versus 10 h). Both automated algorithms provided accurate 3D bone volumetric descriptions for MR-based measures in the hip region. The highly computational efficient ASM-based approach is more likely suitable for future clinical applications such as extracting bone-cartilage interfaces for potential cartilage segmentation.

  18. Inferring spatial clouds statistics from limited field-of-view, zenith observations

    Energy Technology Data Exchange (ETDEWEB)

    Sun, C.H.; Thorne, L.R. [Sandia National Labs., Livermore, CA (United States)

    1996-04-01

    Many of the Cloud and Radiation Testbed (CART) measurements produce a time series of zenith observations, but spatial averages are often the desired data product. One possible approach to deriving spatial averages from temporal averages is to invoke Taylor`s hypothesis where and when it is valid. Taylor`s hypothesis states that when the turbulence is small compared with the mean flow, the covariance in time is related to the covariance in space by the speed of the mean flow. For clouds fields, Taylor`s hypothesis would apply when the {open_quotes}local{close_quotes} turbulence is small compared with advective flow (mean wind). The objective of this study is to determine under what conditions Taylor`s hypothesis holds or does not hold true for broken cloud fields.

  19. MAIN-BELT ASTEROIDS IN THE K2 ENGINEERING FIELD OF VIEW

    International Nuclear Information System (INIS)

    Szabó, R.; Sárneczky, K.; Szabó, Gy. M.; Pál, A.; Kiss, Cs. P.; Kiss, L. L.; Csák, B.; Illés, L.; Rácz, G.

    2015-01-01

    Unlike NASA’s original Kepler Discovery Mission, the renewed K2 Mission will target the plane of the Ecliptic, observing each field for approximately 75 days. This will bring new opportunities and challenges, in particular the presence of a large number of main-belt asteroids that will contaminate the photometry. The large pixel size makes K2 data susceptible to the effects of apparent minor planet encounters. Here, we investigate the effects of asteroid encounters on photometric precision using a subsample of the K2 engineering data taken in 2014 February. We show examples of asteroid contamination to facilitate their recognition and distinguish these events from other error sources. We conclude that main-belt asteroids will have considerable effects on K2 photometry of a large number of photometric targets during the Mission that will have to be taken into account. These results will be readily applicable for future space photometric missions applying large-format CCDs, such as TESS and PLATO

  20. Effect of field of view on MR diagnosis of rotator cuff tears

    International Nuclear Information System (INIS)

    Tuite, M.J.; Yandow, D.R.; De Smet, A.A.; Orwin, J.F.; Quintana, F.A.

    1995-01-01

    One hundred shoulder MR scans with surgical correlation were evaluated for the presence or absence of a cuff tear. The sensitivity and specificity of MR relative to the surgical results were determined for the 59 patients scanned with a 24-cm FOV, and the 41 patients scanned with an 18-cm FOV. All other imaging parameters including acquisition time were identical. The sensitivity and specificity of the two groups were compared using a t-test. The specificity of MR for diagnosing a rotator cuff tear improved from 0.65 for the 24-cm FOV group to 0.89 for the 18-cm FOV group (P = 0.04). The sensitivity changed from 0.91 to 0.96 (P = 0.25). Reducing the FOV from 24 cm to 18 cm results in a statistically significant improvement in specificity of MR for diagnosing rotator cuff tears. (orig./MG)

  1. Effect of field of view on MR diagnosis of rotator cuff tears

    Energy Technology Data Exchange (ETDEWEB)

    Tuite, M J [Dept. of Radiology, Univ. of Wisconsin Clinical Science Center, Madison, WI (United States); Yandow, D R [Dept. of Radiology, Univ. of Wisconsin Clinical Science Center, Madison, WI (United States); De Smet, A A [Dept. of Radiology, Univ. of Wisconsin Clinical Science Center, Madison, WI (United States); Orwin, J F [Div. of Orthopedic Surgery, Univ. of Wisconsin Clinical Science Center, Madison, WI (United States); Quintana, F A [Dept. of Biostatistics, Univ. of Wisconsin Clinical Science Center, Madison, WI (United States)

    1995-10-01

    One hundred shoulder MR scans with surgical correlation were evaluated for the presence or absence of a cuff tear. The sensitivity and specificity of MR relative to the surgical results were determined for the 59 patients scanned with a 24-cm FOV, and the 41 patients scanned with an 18-cm FOV. All other imaging parameters including acquisition time were identical. The sensitivity and specificity of the two groups were compared using a t-test. The specificity of MR for diagnosing a rotator cuff tear improved from 0.65 for the 24-cm FOV group to 0.89 for the 18-cm FOV group (P = 0.04). The sensitivity changed from 0.91 to 0.96 (P = 0.25). Reducing the FOV from 24 cm to 18 cm results in a statistically significant improvement in specificity of MR for diagnosing rotator cuff tears. (orig./MG)

  2. Stability of deep features across CT scanners and field of view using a physical phantom

    Science.gov (United States)

    Paul, Rahul; Shafiq-ul-Hassan, Muhammad; Moros, Eduardo G.; Gillies, Robert J.; Hall, Lawrence O.; Goldgof, Dmitry B.

    2018-02-01

    Radiomics is the process of analyzing radiological images by extracting quantitative features for monitoring and diagnosis of various cancers. Analyzing images acquired from different medical centers is confounded by many choices in acquisition, reconstruction parameters and differences among device manufacturers. Consequently, scanning the same patient or phantom using various acquisition/reconstruction parameters as well as different scanners may result in different feature values. To further evaluate this issue, in this study, CT images from a physical radiomic phantom were used. Recent studies showed that some quantitative features were dependent on voxel size and that this dependency could be reduced or removed by the appropriate normalization factor. Deep features extracted from a convolutional neural network, may also provide additional features for image analysis. Using a transfer learning approach, we obtained deep features from three convolutional neural networks pre-trained on color camera images. An we examination of the dependency of deep features on image pixel size was done. We found that some deep features were pixel size dependent, and to remove this dependency we proposed two effective normalization approaches. For analyzing the effects of normalization, a threshold has been used based on the calculated standard deviation and average distance from a best fit horizontal line among the features' underlying pixel size before and after normalization. The inter and intra scanner dependency of deep features has also been evaluated.

  3. Effect of age and pop out distracter on attended field of view

    Directory of Open Access Journals (Sweden)

    Raiju J. Babu

    2014-10-01

    Conclusion: Better viewing efficiency was observed in younger individuals compared to older individuals. Difficulty in disregarding irrelevant stimuli and thereby resorting to inefficient search strategy is proposed as the reason for the differences. The finding that both older and younger individuals are not affected significantly by the presence of the irrelevant pop out distracter has implications in situations such as driving or hazard avoidance. In such scenarios, search performance is likely not impaired beyond what is found with distracters (visual clutter in the environment.

  4. MAIN-BELT ASTEROIDS IN THE K2 ENGINEERING FIELD OF VIEW

    Energy Technology Data Exchange (ETDEWEB)

    Szabó, R.; Sárneczky, K.; Szabó, Gy. M.; Pál, A.; Kiss, Cs. P.; Kiss, L. L. [Konkoly Observatory, Research Centre for Astronomy and Earth Sciences, Hungarian Academy of Sciences, H-1121 Budapest, Konkoly Thege Miklós út 15-17 (Hungary); Csák, B. [Gothard-Lendület Research Team, H-9704 Szombathely, Szent Imre herceg út 112 (Hungary); Illés, L.; Rácz, G., E-mail: rszabo@konkoly.hu [Eötvös Loránd Tudományegyetem, H-1117 Pázmány Péter sétány 1/A, Budapest (Hungary)

    2015-03-15

    Unlike NASA’s original Kepler Discovery Mission, the renewed K2 Mission will target the plane of the Ecliptic, observing each field for approximately 75 days. This will bring new opportunities and challenges, in particular the presence of a large number of main-belt asteroids that will contaminate the photometry. The large pixel size makes K2 data susceptible to the effects of apparent minor planet encounters. Here, we investigate the effects of asteroid encounters on photometric precision using a subsample of the K2 engineering data taken in 2014 February. We show examples of asteroid contamination to facilitate their recognition and distinguish these events from other error sources. We conclude that main-belt asteroids will have considerable effects on K2 photometry of a large number of photometric targets during the Mission that will have to be taken into account. These results will be readily applicable for future space photometric missions applying large-format CCDs, such as TESS and PLATO.

  5. KMTNET: A Network of 1.6 m Wide-Field Optical Telescopes Installed at Three Southern Observatories

    Science.gov (United States)

    Kim, Seung-Lee; Lee, Chung-Uk; Park, Byeong-Gon; Kim, Dong-Jin; Cha, Sang-Mok; Lee, Yongseok; Han, Cheongho; Chun, Moo-Young; Yuk, Insoo

    2016-02-01

    The Korea Microlensing Telescope Network (KMTNet) is a wide-field photometric system installed by the Korea Astronomy and Space Science Institute (KASI). Here, we present the overall technical specifications of the KMTNet observation system, test observation results, data transfer and image processing procedure, and finally, the KMTNet science programs. The system consists of three 1.6 m wide-field optical telescopes equipped with mosaic CCD cameras of 18k by 18k pixels. Each telescope provides a 2.0 by 2.0 square degree field of view. We have finished installing all three telescopes and cameras sequentially at the Cerro-Tololo Inter-American Observatory (CTIO) in Chile, the South African Astronomical Observatory (SAAO) in South Africa, and the Siding Spring Observatory (SSO) in Australia. This network of telescopes, which is spread over three different continents at a similar latitude of about -30 degrees, enables 24-hour continuous monitoring of targets observable in the Southern Hemisphere. The test observations showed good image quality that meets the seeing requirement of less than 1.0 arcsec in I-band. All of the observation data are transferred to the KMTNet data center at KASI via the international network communication and are processed with the KMTNet data pipeline. The primary scientific goal of the KMTNet is to discover numerous extrasolar planets toward the Galactic bulge by using the gravitational microlensing technique, especially earth-mass planets in the habitable zone. During the non-bulge season, the system is used for wide-field photometric survey science on supernovae, asteroids, and external galaxies.

  6. Wide area continuous offender monitoring

    Energy Technology Data Exchange (ETDEWEB)

    Hoshen, J. [Lucent Technologies (United States); Drake, G. [New Mexico Dept. of Corrections, Santa Fe, NM (United States); Spencer, D. [Sandia National Labs., Albuquerque, NM (United States)

    1996-11-01

    The corrections system in the U.S. is supervising over five million offenders. This number is rising fast and so are the direct and indirect costs to society. To improve supervision and reduce the cost of parole and probation, first generation home arrest systems were introduced in 1987. While these systems proved to be helpful to the corrections system, their scope is rather limited because they only cover an offender at a single location and provide only a partial time coverage. To correct the limitations of first-generation systems, second-generation wide area continuous electronic offender monitoring systems, designed to monitor the offender at all times and locations, are now on the drawing board. These systems use radio frequency location technology to track the position of offenders. The challenge for this technology is the development of reliable personal locator devices that are small, lightweight, with long operational battery life, and indoors/outdoors accuracy of 100 meters or less. At the center of a second-generation system is a database that specifies the offender`s home, workplace, commute, and time the offender should be found in each. The database could also define areas from which the offender is excluded. To test compliance, the system would compare the observed coordinates of the offender with the stored location for a given time interval. Database logfiles will also enable law enforcement to determine if a monitored offender was present at a crime scene and thus include or exclude the offender as a potential suspect.

  7. Wide spectral band beam analysis

    Science.gov (United States)

    Aharon, Oren

    2015-03-01

    The reality in laser beam profiling is that measurements are performed over a wide spectrum of wavelengths and power ranges. Many applications use multiple laser wavelengths with very different power levels, a fact which dictates a need for a better measuring tool. Rapid progress in the fiber laser area has increased the demand for lasers in the wavelength range of 900 - 1030 nm, while the telecommunication market has increased the demand for wavelength range of 1300nm - 1600 nm, on the other hand the silicone chip manufacturing and mass production requirements tend to lower the laser wavelength towards the 190nm region. In many cases there is a need to combine several lasers together in order to perform a specific task. A typical application is to combine one visible laser for pointing, with a different laser for material processing with a very different wavelength and power level. The visible laser enables accurate pointing before the second laser is operated. The beam profile of the intensity distribution is an important parameter that indicates how a laser beam will behave in an application. Currently a lab, where many different lasers are used, will find itself using various laser beam profilers from several vendors with different specifications and accuracies. It is the propose of this article to present a technological breakthrough in the area of detectors, electronics and optics allowing intricate measurements of lasers with different wavelength and with power levels that vary many orders of magnitude by a single beam profiler.

  8. Cost-effective and compact wide-field fluorescent imaging on a cell-phone.

    Science.gov (United States)

    Zhu, Hongying; Yaglidere, Oguzhan; Su, Ting-Wei; Tseng, Derek; Ozcan, Aydogan

    2011-01-21

    We demonstrate wide-field fluorescent and darkfield imaging on a cell-phone with compact, light-weight and cost-effective optical components that are mechanically attached to the existing camera unit of the cell-phone. For this purpose, we used battery powered light-emitting diodes (LEDs) to pump the sample of interest from the side using butt-coupling, where the pump light was guided within the sample cuvette to uniformly excite the specimen. The fluorescent emission from the sample was then imaged using an additional lens that was positioned right in front of the existing lens of the cell-phone camera. Because the excitation occurs through guided waves that propagate perpendicular to our detection path, an inexpensive plastic colour filter was sufficient to create the dark-field background required for fluorescent imaging, without the need for a thin-film interference filter. We validate the performance of this platform by imaging various fluorescent micro-objects in 2 colours (i.e., red and green) over a large field-of-view (FOV) of ∼81 mm(2) with a raw spatial resolution of ∼20 μm. With additional digital processing of the captured cell-phone images, through the use of compressive sampling theory, we demonstrate ∼2 fold improvement in our resolving power, achieving ∼10 μm resolution without a trade-off in our FOV. Further, we also demonstrate darkfield imaging of non-fluorescent specimen using the same interface, where this time the scattered light from the objects is detected without the use of any filters. The capability of imaging a wide FOV would be exceedingly important to probe large sample volumes (e.g., >0.1 mL) of e.g., blood, urine, sputum or water, and for this end we also demonstrate fluorescent imaging of labeled white-blood cells from whole blood samples, as well as water-borne pathogenic protozoan parasites such as Giardia Lamblia cysts. Weighing only ∼28 g (∼1 ounce), this compact and cost-effective fluorescent imaging platform

  9. PMAS: The Potsdam Multi-Aperture Spectrophotometer. II. The Wide Integral Field Unit PPak

    NARCIS (Netherlands)

    Kelz, Andreas; Verheijen, Marc A. W.; Roth, Martin M.; Bauer, Svend M.; Becker, Thomas; Paschke, Jens; Popow, Emil; Sánchez, Sebastian F.; Laux, Uwe

    2006-01-01

    PPak is a new fiber-based integral field unit (IFU) developed at the Astrophysical Institute of Potsdam and implemented as a module into the existing Potsdam Multi-Aperture Spectrophotometer (PMAS) spectrograph. The purpose of PPak is to provide an extended field of view with a large

  10. Unit 148 - World Wide Web Basics

    OpenAIRE

    148, CC in GIScience; Yeung, Albert K.

    2000-01-01

    This unit explains the characteristics and the working principles of the World Wide Web as the most important protocol of the Internet. Topics covered in this unit include characteristics of the World Wide Web; using the World Wide Web for the dissemination of information on the Internet; and using the World Wide Web for the retrieval of information from the Internet.

  11. Satellite Ocean Biology: Past, Present, Future

    Science.gov (United States)

    McClain, Charles R.

    2012-01-01

    Since 1978 when the first satellite ocean color proof-of-concept sensor, the Nimbus-7 Coastal Zone Color Scanner, was launched, much progress has been made in refining the basic measurement concept and expanding the research applications of global satellite time series of biological and optical properties such as chlorophyll-a concentrations. The seminar will review the fundamentals of satellite ocean color measurements (sensor design considerations, on-orbit calibration, atmospheric corrections, and bio-optical algorithms), scientific results from the Sea-viewing Wide Field-of-view Sensor (SeaWiFS) and Moderate resolution Imaging Spectroradiometer (MODIS) missions, and the goals of future NASA missions such as PACE, the Aerosol, Cloud, Ecology (ACE), and Geostationary Coastal and Air Pollution Events (GeoCAPE) missions.

  12. Thermocline Regulated Seasonal Evolution of Surface Chlorophyll in the Gulf of Aden

    KAUST Repository

    Hoteit, Ibrahim

    2015-04-01

    The Gulf of Aden, although subject to seasonally reversing monsoonal winds, has been previously reported as an oligotrophic basin during summer, with elevated chlorophyll concentrations only occurring during winter due to convective mixing. However, the Sea-Viewing Wide Field-of-View Sensor (SeaWiFS) ocean color data reveal that the Gulf of Aden also exhibits a prominent summer chlorophyll bloom and sustains elevated chlorophyll concentrations throughout the fall, and is a biophysical province distinct from the adjacent Arabian Sea. Climatological hydrographic data suggest that the thermocline, hence the nutricline, in the entire gulf is markedly shoaled by the southwest monsoon during summer and fall. Under this condition, cyclonic eddies in the gulf can effectively pump deep nutrients to the surface layer and lead to the chlorophyll bloom in late summer, and, after the transition to the northeast monsoon in fall, coastal upwelling driven by the northeasterly winds produces a pronounced increase in surface chlorophyll concentrations along the Somali coast.

  13. Early Spring Dust over the Mediterranean Sea

    Science.gov (United States)

    2002-01-01

    The Sea-viewing Wide Field-of-view Sensor (SeaWiFS) observed this large cloud of dust (brownish pixels) blowing from northern Africa across the Mediterranean Sea on March 4, 2002. The dust can be seen clearly blowing across Southern Italy, Albania, Greece, and Turkey-all along the Mediterranean's northeastern shoreline. Notice that there also appears to be human-made aerosol pollution (greyish pixels) pooling in the air just south of the Italian Alps and blowing southeastward over the Adriatic Sea. The Alps can be easily identified as the crescent-shaped, snow-capped mountain range in the top center of this true-color scene. There also appears to be a similar haze over Austria, Hungary, and Yugoslavia to the north and east of Italy. Image courtesy the SeaWiFS Project, NASA/Goddard Space Flight Center, and ORBIMAGE

  14. The Ocean's Carbon Factory: Ocean Composition. The Growth Patterns of Phytoplankton Species

    Science.gov (United States)

    Gregg, Watson

    2000-01-01

    According to biological data recorded by the Sea-Viewing Wide Field-of-View Sensor (SeaWiFS) satellite, the ocean contains nearly half of all the Earth's photosynthesis activity. Through photosynthesis, plant life forms use carbon from the atmosphere, and in return, plants produce the oxygen that life requires. In effect, ocean chlorophyll works like a factory, taking carbon and "manufacturing" the air we breathe. Most ocean-bound photosynthesis is performed by single-celled plants called phytoplankton. "These things are so small," according to Michael Behrenfeld, a researcher at NASA Goddard Space Flight Center, "that if you take hundreds of them and stack them end-to-end, the length of that stack is only the thickness of a penny". The humble phytoplankton species plays a vital role in balancing the amounts of oxygen and carbon dioxide in the atmosphere. Therefore, understanding exactly how phytoplankton growth works is important.

  15. SeaWiFS technical report series. Volume 4: An analysis of GAC sampling algorithms. A case study

    Science.gov (United States)

    Yeh, Eueng-Nan (Editor); Hooker, Stanford B. (Editor); Hooker, Stanford B. (Editor); Mccain, Charles R. (Editor); Fu, Gary (Editor)

    1992-01-01

    The Sea-viewing Wide Field-of-view Sensor (SeaWiFS) instrument will sample at approximately a 1 km resolution at nadir which will be broadcast for reception by realtime ground stations. However, the global data set will be comprised of coarser four kilometer data which will be recorded and broadcast to the SeaWiFS Project for processing. Several algorithms for degrading the one kilometer data to four kilometer data are examined using imagery from the Coastal Zone Color Scanner (CZCS) in an effort to determine which algorithm would best preserve the statistical characteristics of the derived products generated from the one kilometer data. Of the algorithms tested, subsampling based on a fixed pixel within a 4 x 4 pixel array is judged to yield the most consistent results when compared to the one kilometer data products.

  16. Superstorm Sweeps Over England

    Science.gov (United States)

    2002-01-01

    A large, low-pressure system swept across the United Kingdom on Monday, spawning at least three tornadoes there before continuing on toward Scandanavia. This image, acquired on October 30, by the Sea-viewing Wide Field-of-view Sensor (SeaWiFS), shows the storm after it brought torrential rain and hurricane-strength winds to Britain in perhaps the worst storm to hit the country since 1987. High seas nearing 23 feet (7 meters) and winds gusting up to 109 mph wreaked havoc on sea traffic, causing delays or cancelled ferries across the English Channel and necessitating the rescue of crews from stranded ships, including a Norwegian freighter and an Italian cargo ship. Image provided by the SeaWiFS Project, NASA/Goddard Space Flight Center, and ORBIMAGE

  17. Calibration Uncertainty in Ocean Color Satellite Sensors and Trends in Long-term Environmental Records

    Science.gov (United States)

    Turpie, Kevin R.; Eplee, Robert E., Jr.; Franz, Bryan A.; Del Castillo, Carlos

    2014-01-01

    Launched in late 2011, the Visible Infrared Imaging Radiometer Suite (VIIRS) aboard the Suomi National Polar-orbiting Partnership (NPP) spacecraft is being evaluated by NASA to determine whether this sensor can continue the ocean color data record established through the Sea-Viewing Wide Field-of-view Sensor (SeaWiFS) and the MODerate resolution Imaging Spectroradiometer (MODIS). To this end, Goddard Space Flight Center generated evaluation ocean color data products using calibration techniques and algorithms established by NASA during the SeaWiFS and MODIS missions. The calibration trending was subjected to some initial sensitivity and uncertainty analyses. Here we present an introductory assessment of how the NASA-produced time series of ocean color is influenced by uncertainty in trending instrument response over time. The results help quantify the uncertainty in measuring regional and global biospheric trends in the ocean using satellite remote sensing, which better define the roles of such records in climate research.

  18. Wide-angle imaging LIDAR (WAIL): a ground-based instrument for monitoring the thickness and density of optically thick clouds

    International Nuclear Information System (INIS)

    Love, Steven P.; Davis, A.B.; Rohde, C.A.; Ho, Cheng

    2001-01-01

    Traditional lidar provides little information on dense clouds beyond the range to their base (ceilometry), due to their extreme opacity. At most optical wavelengths, however, laser photons are not absorbed but merely scattered out of the beam, and thus eventually escape the cloud via multiple scattering, producing distinctive extended space- and time-dependent patterns which are, in essence, the cloud's radiative Green functions. These Green functions, essentially 'movies' of the time evolution of the spatial distribution of escaping light, are the primary data products of a new type of lidar: Wide Angle Imaging Lidar (WAIL). WAIL data can be used to infer both optical depth and physical thickness of clouds, and hence the cloud liquid water content. The instrumental challenge is to accommodate a radiance field varying over many orders of magnitude and changing over widely varying time-scales. Our implementation uses a high-speed microchannel plate/crossed delay line imaging detector system with a 60-degree full-angle field of view, and a 532 nm doubled Nd:YAG laser. Nighttime field experiments testing various solutions to this problem show excellent agreement with diffusion theory, and retrievals yield plausible values for the optical and geometrical parameters of the observed cloud decks.

  19. Inland-coastal water interaction: Remote sensing application for shallow-water quality and algal blooms modeling

    Science.gov (United States)

    Melesse, Assefa; Hajigholizadeh, Mohammad; Blakey, Tara

    2017-04-01

    In this study, Landsat 8 and Sea-Viewing Wide Field-of-View Sensor (SeaWIFS) sensors were used to model the spatiotemporal changes of four water quality parameters: Landsat 8 (turbidity, chlorophyll-a (chl-a), total phosphate, and total nitrogen) and Sea-Viewing Wide Field-of-View Sensor (SeaWIFS) (algal blooms). The study was conducted in Florda bay, south Florida and model outputs were compared with in-situ observed data. The Landsat 8 based study found that, the predictive models to estimate chl-a and turbidity concentrations, developed through the use of stepwise multiple linear regression (MLR), gave high coefficients of determination in dry season (wet season) (R2 = 0.86(0.66) for chl-a and R2 = 0.84(0.63) for turbidity). Total phosphate and TN were estimated using best-fit multiple linear regression models as a function of Landsat TM and OLI,127 and ground data and showed a high coefficient of determination in dry season (wet season) (R2 = 0.74(0.69) for total phosphate and R2 = 0.82(0.82) for TN). Similarly, the ability of SeaWIFS for chl-a retrieval from optically shallow coastal waters by applying algorithms specific to the pixels' benthic class was evaluated. Benthic class was determined through satellite image-based classification methods. It was found that benthic class based chl-a modeling algorithm was better than the existing regionally-tuned approach. Evaluation of the residuals indicated the potential for further improvement to chl-a estimation through finer characterization of benthic environments. Key words: Landsat, SeaWIFS, water quality, Florida bay, Chl-a, turbidity

  20. Design Evolution of the Wide Field Infrared Survey Telescope Using Astrophysics Focused Telescope Assets (WFIRST-AFTA) and Lessons Learned

    Science.gov (United States)

    Peabody, Hume L.; Peters, Carlton V.; Rodriguez-Ruiz, Juan E.; McDonald, Carson S.; Content, David A.; Jackson, Clifton E.

    2015-01-01

    The design of the Wide Field Infrared Survey Telescope using Astrophysics Focused Telescope Assets (WFIRST-AFTA) continues to evolve as each design cycle is analyzed. In 2012, two Hubble sized (2.4 m diameter) telescopes were donated to NASA from elsewhere in the Federal Government. NASA began investigating potential uses for these telescopes and identified WFIRST as a mission to benefit from these assets. With an updated, deeper, and sharper field of view than previous design iterations with a smaller telescope, the optical designs of the WFIRST instruments were updated and the mechanical and thermal designs evolved around the new optical layout. Beginning with Design Cycle 3, significant analysis efforts yielded a design and model that could be evaluated for Structural-Thermal-Optical-Performance (STOP) purposes for the Wide Field Imager (WFI) and provided the basis for evaluating the high level observatory requirements. Development of the Cycle 3 thermal model provided some valuable analysis lessons learned and established best practices for future design cycles. However, the Cycle 3 design did include some major liens and evolving requirements which were addressed in the Cycle 4 Design. Some of the design changes are driven by requirements changes, while others are optimizations or solutions to liens from previous cycles. Again in Cycle 4, STOP analysis was performed and further insights into the overall design were gained leading to the Cycle 5 design effort currently underway. This paper seeks to capture the thermal design evolution, with focus on major design drivers, key decisions and their rationale, and lessons learned as the design evolved.

  1. Introduction to the world wide web.

    Science.gov (United States)

    Downes, P K

    2007-05-12

    The World Wide Web used to be nicknamed the 'World Wide Wait'. Now, thanks to high speed broadband connections, browsing the web has become a much more enjoyable and productive activity. Computers need to know where web pages are stored on the Internet, in just the same way as we need to know where someone lives in order to post them a letter. This section explains how the World Wide Web works and how web pages can be viewed using a web browser.

  2. Active optics and modified-Rumsey wide-field telescopes: MINITRUST demonstrators with vase- and tulip-form mirrors

    Science.gov (United States)

    Lemaître, Gérard R.; Montiel, Pierre; Joulié, Patrice; Dohlen, Kjetil; Lanzoni, Patrick

    2005-12-01

    Wide-field astronomy requires the development of larger aperture telescopes. The optical properties of a three-mirror modified-Rumsey design provide significant advantages when compared to other telescope designs: (i) at any wavelength, the design has a flat field and is anastigmatic; (ii) the system is extremely compact, i.e., it is almost four times shorter than a Schmidt. Compared to the equally compact flat-field Ritchey-Chrétien with a doublet-lens corrector, as developed for the Sloan digital sky survey - and which requires the polishing of six optical surfaces - the proposed modified-Rumsey design requires only a two-surface polishing and provides a better imaging quality. All the mirrors are spheroids of the hyperboloid type. Starting from the classical Rumsey design, it is shown that the use of all eight available free parameters allows the simultaneous aspherization of the primary and tertiary mirrors by active optics methods from a single deformable substrate. The continuity conditions between the primary and the tertiary hyperbolizations are achieved by an intermediate narrow ring of constant thickness that is not optically used. After the polishing of a double vase form in a spherical shape, the primary-tertiary hyperbolizations are achieved by in situ stressing. The tulip-form secondary is hyperbolized by stress polishing. Other active optics alternatives are possible for a space telescope. The modified-Rumsey design is of interest for developing large space- and ground-based survey telescopes in UV, visible, or IR ranges, such as currently demonstrated with the construction of identical telescopes MINITRUST-1 and -2, f/5 - 2° field of view. Double-pass optical tests show diffraction-limited images.

  3. Challenges and advantages in wide-field optical coherence tomography angiography imaging of the human retinal and choroidal vasculature at 1.7-MHz A-scan rate

    Science.gov (United States)

    Poddar, Raju; Migacz, Justin V.; Schwartz, Daniel M.; Werner, John S.; Gorczynska, Iwona

    2017-10-01

    We present noninvasive, three-dimensional, depth-resolved imaging of human retinal and choroidal blood circulation with a swept-source optical coherence tomography (OCT) system at 1065-nm center wavelength. Motion contrast OCT imaging was performed with the phase-variance OCT angiography method. A Fourier-domain mode-locked light source was used to enable an imaging rate of 1.7 MHz. We experimentally demonstrate the challenges and advantages of wide-field OCT angiography (OCTA). In the discussion, we consider acquisition time, scanning area, scanning density, and their influence on visualization of selected features of the retinal and choroidal vascular networks. The OCTA imaging was performed with a field of view of 16 deg (5 mm×5 mm) and 30 deg (9 mm×9 mm). Data were presented in en face projections generated from single volumes and in en face projection mosaics generated from up to 4 datasets. OCTA imaging at 1.7 MHz A-scan rate was compared with results obtained from a commercial OCTA instrument and with conventional ophthalmic diagnostic methods: fundus photography, fluorescein, and indocyanine green angiography. Comparison of images obtained from all methods is demonstrated using the same eye of a healthy volunteer. For example, imaging of retinal pathology is presented in three cases of advanced age-related macular degeneration.

  4. Wireless Wide Area Networks for School Districts.

    Science.gov (United States)

    Nair, Prakash

    This paper considers a basic question that many schools districts face in attempting to develop affordable, expandable district-wide computer networks that are resistant to obsolescence: Should these wide area networks (WANs) employ wireless technology, stick to venerable hard-wired solutions, or combine both. This publication explores the…

  5. World-Wide Web: The Information Universe.

    Science.gov (United States)

    Berners-Lee, Tim; And Others

    1992-01-01

    Describes the World-Wide Web (W3) project, which is designed to create a global information universe using techniques of hypertext, information retrieval, and wide area networking. Discussion covers the W3 data model, W3 architecture, the document naming scheme, protocols, document formats, comparison with other systems, experience with the W3…

  6. Reduction operator for wide-SIMDs reconsidered

    NARCIS (Netherlands)

    Waeijen, L.J.W.; She, D.; Corporaal, H.; He, Y.

    2014-01-01

    It has been shown that wide Single Instruction Multiple Data architectures (wide-SIMDs) can achieve high energy efficiency, especially in domains such as image and vision processing. In these and various other application domains, reduction is a frequently encountered operation, where multiple input

  7. Innovation in Science Education - World-Wide.

    Science.gov (United States)

    Baez, Albert V.

    The purpose of this book is to promote improvements in science education, world-wide, but particularly in developing countries. It is addressed to those in positions to make effective contributions to the improvement of science education. The world-wide role of science education, the goals of innovative activities, past experience in efforts to…

  8. Management van World-Wide Web Servers

    NARCIS (Netherlands)

    van Hengstum, F.P.H.; Pras, Aiko

    1996-01-01

    Het World Wide Web is een populaire Internet toepassing waarmee het mogelijk is documenten aan willekeurige Internet gebruikers aan te bieden. Omdat hiervoor nog geen voorzieningen zijn getroffen, was het tot voor kort niet goed mogelijk het World Wide Web op afstand te beheren. De Universiteit

  9. Consistency in the World Wide Web

    DEFF Research Database (Denmark)

    Thomsen, Jakob Grauenkjær

    Tim Berners-Lee envisioned that computers will behave as agents of humans on the World Wide Web, where they will retrieve, extract, and interact with information from the World Wide Web. A step towards this vision is to make computers capable of extracting this information in a reliable...... and consistent way. In this dissertation we study steps towards this vision by showing techniques for the specication, the verication and the evaluation of the consistency of information in the World Wide Web. We show how to detect certain classes of errors in a specication of information, and we show how...... the World Wide Web, in order to help perform consistent evaluations of web extraction techniques. These contributions are steps towards having computers reliable and consistently extract information from the World Wide Web, which in turn are steps towards achieving Tim Berners-Lee's vision. ii...

  10. Combined 60° Wide-Field Choroidal Thickness Maps and High-Definition En Face Vasculature Visualization Using Swept-Source Megahertz OCT at 1050 nm.

    Science.gov (United States)

    Mohler, Kathrin J; Draxinger, Wolfgang; Klein, Thomas; Kolb, Jan Philip; Wieser, Wolfgang; Haritoglou, Christos; Kampik, Anselm; Fujimoto, James G; Neubauer, Aljoscha S; Huber, Robert; Wolf, Armin

    2015-10-01

    To demonstrate ultrahigh-speed swept-source optical coherence tomography (SS-OCT) at 1.68 million A-scans/s for choroidal imaging in normal and diseased eyes over a ∼60° field of view. To investigate and correlate wide-field three-dimensional (3D) choroidal thickness (ChT) and vascular patterns using ChT maps and coregistered high-definition en face images extracted from a single densely sampled Megahertz-OCT (MHz-OCT) dataset. High-definition, ∼60° wide-field 3D datasets consisting of 2088 × 1024 A-scans were acquired using a 1.68 MHz prototype SS-OCT system at 1050 nm based on a Fourier-domain mode-locked laser. Nine subjects (nine eyes) with various chorioretinal diseases or without ocular pathology are presented. Coregistered ChT maps, choroidal summation maps, and depth-resolved en face images referenced to either the retinal pigment epithelium or the choroidal-scleral interface were generated using manual segmentation. Wide-field ChT maps showed a large inter- and intraindividual variance in peripheral and central ChT. In only four of the nine eyes, the location with the largest ChT was coincident with the fovea. The anatomy of the large lumen vessels of the outer choroid seems to play a major role in determining the global ChT pattern. Focal ChT changes with large thickness gradients were observed in some eyes. Different ChT and vascular patterns could be visualized over ∼60° in patients for the first time using OCT. Due to focal ChT changes, a high density of thickness measurements may be favorable. High-definition depth-resolved en face images are complementary to cross sections and thickness maps and enhance the interpretation of different ChT patterns.

  11. The World Wide Web of War

    National Research Council Canada - National Science Library

    Smith, Craig A

    2006-01-01

    Modern communications, combined with the near instantaneous publication of information on the World Wide Web, are providing the means to dramatically affect the pursuit, conduct, and public opinion of war on both sides...

  12. Nasa-wide Standard Administrative Systems

    Science.gov (United States)

    Schneck, P.

    1984-01-01

    Factors to be considered in developing agency-wide standard administrative systems for NASA include uniformity of hardware and software; centralization vs. decentralization; risk exposure; and models for software development.

  13. IOT Overview: Wide-Field Imaging

    Science.gov (United States)

    Selman, F. J.

    The Wide Field Imager (WFI) instrument at La Silla has been the workhorse of wide-field imaging instruments at ESO for several years. In this contribution I will summarize the issues relating to its productivity for the community both in terms of the quality and quantity of data that has come out of it. Although only surveys of limited scope have been completed using WFI, it is ESO's stepping-stone to the new generation of survey telescopes.

  14. AA, wide quadrupole on measurement stand

    CERN Multimedia

    CERN PhotoLab

    1981-01-01

    Please look up 8101024 first. Shims and washers on the wide quadrupoles (QFW, QDW; located in the lattice where dispersion was large) served mostly for corrections of those lattice parameters which were a function of momentum. After mounting shims and washers, the quadrupoles were measured to determine their magnetic centre and to catalogue the effect of washer constellations. Raymond Brown is busy measuring a wide quad.

  15. AA, assembly of wide bending magnet

    CERN Multimedia

    CERN PhotoLab

    1980-01-01

    The very particular lattice of the AA required 2 types of dipoles (bending magnets; BST, short and wide; BLG, long and narrow). The wide ones had a steel length of 2.71 m, a "good field" width of 0.564 m, and a weight of about 75 t. Here we see the copper coils being hoisted onto the lower half of a BST. See also 7811105, 8006050. For a BLG, see 8001044.

  16. Emergency Medicine for medical students world wide!

    DEFF Research Database (Denmark)

    Perinpam, Larshan; Thi Huynh, Anh-Nhi

    2015-01-01

    A guest blog from Larshan Perinpam (President of ISAEM) and Anh-Nhi Thi Huynh (Vice president of external affairs, ISAEM) - http://blogs.bmj.com/emj/2015/04/17/emergency-medicine-for-medical-students-world-wide/......A guest blog from Larshan Perinpam (President of ISAEM) and Anh-Nhi Thi Huynh (Vice president of external affairs, ISAEM) - http://blogs.bmj.com/emj/2015/04/17/emergency-medicine-for-medical-students-world-wide/...

  17. Wide dynamic range beam profile monitor

    International Nuclear Information System (INIS)

    Lee, D.M.; Brown, D.; Hardekopf, R.; Bilskie, J.R.; van Dyck, O.B.V.

    1985-01-01

    An economical harp multiplexer system has been developed to achieve a wide dynamic range. The harp system incorporates a pneumatically actuated harp detector with ceramic boards and carbon wires; a high-sensitivity multiplexer packaged in a double-wide NIM module; and flat, shielded ribbon cable consisting of individual twisted pairs. The system multiplexes 30 wires in each of the x and y planes simultaneously and operates with or without computer control. The system has operated in beams of 100 nA to 1 mA, 1- to 120-Hz repetition rate, with a signal-to-noise ratio of greater than 10/1

  18. Brca1/p53 deficient mouse breast tumor hemodynamics during hyperoxic respiratory challenge monitored by a novel wide-field functional imaging (WiFI) system

    Science.gov (United States)

    Moy, Austin; Kim, Jae G.; Lee, Eva Y. H. P.; Tromberg, Bruce; Cerussi, Albert; Choi, Bernard

    2009-02-01

    Current imaging modalities allow precise visualization of tumors but do not enable quantitative characterization of the tumor metabolic state. Such quantitative information would enhance our understanding of tumor progression and response to treatment, and to our overall understanding of tumor biology. To address this problem, we have developed a wide-field functional imaging (WiFI) instrument which combines two optical imaging modalities, spatially modulated imaging (MI) and laser speckle imaging (LSI). Our current WiFI imaging protocol consists of multispectral imaging in the near infrared (650-980 nm) spectrum, over a wide (7 cm × 5 cm) field of view. Using MI, the spatially-resolved reflectance of sinusoidal patterns projected onto the tissue is assessed, and optical properties of the tissue are estimated using a Monte Carlo model. From the spatial maps of local absorption and reduced scattering coefficients, tissue composition information is extracted in the form of oxy-, deoxy-, and total hemoglobin concentrations, and percentage of lipid and water. Using LSI, the reflectance of a 785 nm laser speckle pattern on the tissue is acquired and analyzed to compute maps of blood perfusion in the tissue. Tissue metabolism state is estimated from the values of blood perfusion, volume and oxygenation state. We currently are employing the WiFI instrument to study tumor development in a BRCA1/p53 deficient mice breast tumor model. The animals are monitored with WiFI during hyperoxic respiratory challenge. At present, four tumors have been measured with WiFI, and preliminary data suggest that tumor metabolic changes during hyperoxic respiratory challenge can be determined.

  19. PSYM-WIDE: A Survey for Large-separation Planetary-mass Companions to Late Spectral Type Members of Young Moving Groups

    Science.gov (United States)

    Naud, Marie-Eve; Artigau, Étienne; Doyon, René; Malo, Lison; Gagné, Jonathan; Lafrenière, David; Wolf, Christian; Magnier, Eugene A.

    2017-09-01

    We present the results of a direct imaging survey for very large separation (>100 au), low-mass companions around 95 nearby young K5-L5 stars and brown dwarfs. They are high-likelihood candidates or confirmed members of the young (≲150 Myr) β Pictoris and AB Doradus moving groups (ABDMG) and the TW Hya, Tucana-Horologium, Columba, Carina, and Argus associations. Images in I\\prime and z\\prime filters were obtained with the Gemini Multi-Object Spectrograph (GMOS) on Gemini South to search for companions down to an apparent magnitude of z\\prime ˜ 22-24 at separations ≳20″ from the targets and in the remainder of the wide 5.‧5 × 5.‧5 GMOS field of view. This allowed us to probe the most distant region where planetary-mass companions could be gravitationally bound to the targets. This region was left largely unstudied by past high-contrast imaging surveys, which probed much closer-in separations. This survey led to the discovery of a planetary-mass (9-13 {M}{Jup}) companion at 2000 au from the M3V star GU Psc, a highly probable member of ABDMG. No other substellar companions were identified. These results allowed us to constrain the frequency of distant planetary-mass companions (5-13 {M}{Jup}) to {0.84}-0.66+6.73% (95% confidence) at semimajor axes between 500 and 5000 au around young K5-L5 stars and brown dwarfs. This is consistent with other studies suggesting that gravitationally bound planetary-mass companions at wide separations from low-mass stars are relatively rare.

  20. Deepest Wide-Field Colour Image in the Southern Sky

    Science.gov (United States)

    2003-01-01

    " (HDF-N in the northern and HDF-S in the southern sky, cf. e.g. ESO PR Photo 35a/98 ), but the field-of-view is about 200 times larger. The present image displays about 50 times more galaxies than the HDF images, and therefore provides a more representative view of the universe . The WFI CDF-S image will now form a most useful basis for the very extensive and systematic census of the population of distant galaxies and quasars, allowing at once a detailed study of all evolutionary stages of the universe since it was about 2 billion years old . These investigations have started and are expected to provide information about the evolution of galaxies in unprecedented detail. They will offer insights into the history of star formation and how the internal structure of galaxies changes with time and, not least, throw light on how these two evolutionary aspects are interconnected. GALAXIES IN THE WFI IMAGE ESO PR Photo 02b/03 ESO PR Photo 02b/03 [Preview - JPEG: 488 x 400 pix - 112k] [Normal - JPEG: 896 x 800 pix - 1.0M] [Full-Res - JPEG: 2591 x 2313 pix - 8.6M] Caption : PR Photo 02b/03 contains a collection of twelve subfields from the full WFI Chandra Deep Field South (WFI CDF-S), centred on (pairs or groups of) galaxies. Each of the subfields measures 2.5 x 2.5 arcmin 2 (635 x 658 pix 2 ; 1 pixel = 0.238 arcsec). North is up and East is left. Technical information is available below. The WFI CDF-S colour image - of which the full field is shown in PR Photo 02a/03 - was constructed from all available observations in the optical B- ,V- and R-bands obtained under good conditions with the Wide Field Imager (WFI) on the 2.2-m MPG/ESO telescope at the ESO La Silla Observatory (Chile), and now stored in the ESO Science Data Archive. It is the "deepest" image ever taken with this instrument. It covers a sky field measuring 36 x 34 arcmin 2 , i.e., an area somewhat larger than that of the full moon. The observations were collected during a period of nearly four years, beginning in

  1. So Wide a Web, So Little Time.

    Science.gov (United States)

    McConville, David; And Others

    1996-01-01

    Discusses new trends in the World Wide Web. Highlights include multimedia; digitized audio-visual files; compression technology; telephony; virtual reality modeling language (VRML); open architecture; and advantages of Java, an object-oriented programming language, including platform independence, distributed development, and pay-per-use software.…

  2. Enterprise-Wide Process & Performance Excellence:

    DEFF Research Database (Denmark)

    Edgeman, Rick; Kristensen, Kai; Eskildsen, Jacob Kjær

    2013-01-01

    Program value proposition, content, organization, and strategy are elaborated herein. This elaboration is the result of careful study of business and social trends, along with careful listening to collaborating enterprises. It is in this latter sense that the Enterprise-Wide Process & Performance...... Excellence certificate program is a product of a co-creation process....

  3. Review The Ooty Wide Field Array

    Indian Academy of Sciences (India)

    c Indian Academy of Sciences. DOI 10.1007/s12036-017-9430-4. Review. The Ooty Wide Field ... salient features of the upgrade, as well as its main science drivers. There are three ..... tecture for low frequency arrays, Ph.D. thesis, Jawaharalal.

  4. Happy 20th Birthday, World Wide Web!

    CERN Multimedia

    2009-01-01

    On 13 March CERN celebrated the 20th anniversary of the World Wide Web. Check out the video interview with Web creator Tim Berners-Lee and find out more about the both the history and future of the Web. To celebrate CERN also launched a brand new website, CERNland, for kids.

  5. Wide Band to ''Double Band'' upgrade

    International Nuclear Information System (INIS)

    Kasper, P.; Currier, R.; Garbincius, P.; Butler, J.

    1988-06-01

    The Wide Band beam currently uses electrons obtained from secondary photon conversions to produce the photon beam incident on the experimental targets. By transporting the positrons produced in these conversions as well as the electrons it is possible to almost double the number of photons delivered to the experiments per primary beam proton. 11 figs

  6. WorldWide Web: Hypertext from CERN.

    Science.gov (United States)

    Nickerson, Gord

    1992-01-01

    Discussion of software tools for accessing information on the Internet focuses on the WorldWideWeb (WWW) system, which was developed at the European Particle Physics Laboratory (CERN) in Switzerland to build a worldwide network of hypertext links using available networking technology. Its potential for use with multimedia documents is also…

  7. Wide-band segmented power distribution networks

    NARCIS (Netherlands)

    Tereshchenko, O.V.; Buesink, Frederik Johannes Karel; Leferink, Frank Bernardus Johannes

    2013-01-01

    This paper discusses a novel design of Power Distribution Network (PDN). By physical structuring of the power plane into repetitive symmetrical and asymmetrical segments of varying size, suppression of the propagation of unwanted noise throughout the PDN over a wide frequency range is achieved.

  8. Digital demodulator for wide bandwidth SAR

    DEFF Research Database (Denmark)

    Jørgensen, Jørn Hjelm

    2000-01-01

    A novel approach to the design of efficient digital quadrature demodulators for wide bandwidth SAR systems is described. Efficiency is obtained by setting the intermediate frequency to 1/4 the ADC sampling frequency. One channel is made filter-free by synchronizing the local oscillator...

  9. Utilization of the world wide web

    International Nuclear Information System (INIS)

    Mohr, P.; Mallard, G.; Ralchenko, U.; Schultz, D.

    1998-01-01

    Two aspects of utilization of the World Wide Web are examined: (i) the communication of technical data through web cites that provide repositories of atomic and molecular data accessible through searchable databases; and (ii) the communication about issues of mutual concern among data producers, data compilers and evaluators, and data users. copyright 1998 American Institute of Physics

  10. News Resources on the World Wide Web.

    Science.gov (United States)

    Notess, Greg R.

    1996-01-01

    Describes up-to-date news sources that are presently available on the Internet and World Wide Web. Highlights include electronic newspapers; AP (Associated Press) sources and Reuters; sports news; stock market information; New York Times; multimedia capabilities, including CNN Interactive; and local and regional news. (LRW)

  11. Telepresence Robots in the Wide Wild World

    NARCIS (Netherlands)

    Bruijnes, Merijn; van Delden, Robby; Vroon, Jered Hendrik

    2017-01-01

    Mobile remote presence systems (MRPs) are the logical next step in telepresence, but what are the ethical, social, legal, and technical implications of such systems going into the wide wild world? We explored these potential issues by immersing ourselves in a range of possible applications by

  12. Re-Framing the World Wide Web

    Science.gov (United States)

    Black, August

    2011-01-01

    The research presented in this dissertation studies and describes how technical standards, protocols, and application programming interfaces (APIs) shape the aesthetic, functional, and affective nature of our most dominant mode of online communication, the World Wide Web (WWW). I examine the politically charged and contentious battle over browser…

  13. The LOFT wide field monitor simulator

    DEFF Research Database (Denmark)

    Donnarumma, I.; Evangelista, Y.; Campana, R.

    2012-01-01

    We present the simulator we developed for the Wide Field Monitor (WFM) aboard the Large Observatory For Xray Timing (LOFT) mission, one of the four ESA M3 candidate missions considered for launch in the 2022–2024 timeframe. The WFM is designed to cover a large FoV in the same bandpass as the Large...

  14. Internet and The World Wide Web

    Indian Academy of Sciences (India)

    Home; Journals; Resonance – Journal of Science Education; Volume 2; Issue 2. Internet and The World Wide Web. Neelima Shrikhande. General Article Volume 2 Issue 2 February 1997 pp 64-74. Fulltext. Click here to view fulltext PDF. Permanent link: https://www.ias.ac.in/article/fulltext/reso/002/02/0064-0074 ...

  15. AA, wide quadrupole on measurement stand

    CERN Multimedia

    CERN PhotoLab

    1981-01-01

    Please look up 8101024 and 8103203 first. Wide quadrupole (QFW, QDW) with end-shims and shimming washers on the measurement stand. With the measurement coil one measured the harmonics of the magnetic field, determined the magnetic centre, and catalogued the effect of washer constellations.

  16. Wide-Screen Cinema and Stereophonic Sound.

    Science.gov (United States)

    Wysotsky, Michael Z.

    Developments in the techniques of wide screen cinema and stereophonic sound throughout the world are detailed in this book. Particular attention is paid to progress in the Soviet Union in these fields. Special emphasis is placed on the Soviet view of stereophonic sound as a vital adjunct in the search for enchanced realism as opposed to the…

  17. Dosimetric impact of image artifact from a wide-bore CT scanner in radiotherapy treatment planning

    Energy Technology Data Exchange (ETDEWEB)

    Wu, Vincent; Podgorsak, Matthew B.; Tran, Tuan-Anh; Malhotra, Harish K.; Wang, Iris Z. [Department of Radiation Medicine, Roswell Park Cancer Institute, Buffalo, New York 14263 (United States); Department of Radiation Medicine, Roswell Park Cancer Institute, Buffalo, New York 14263 and Department of Physiology and Biophysics, State University of New York at Buffalo, Buffalo, New York 14214 (United States); Department of Radiation Medicine, Roswell Park Cancer Institute, Buffalo, New York 14263 (United States); Department of Radiation Medicine, Roswell Park Cancer Institute, Buffalo, New York 14263 and Department of Physiology and Biophysics, State University of New York at Buffalo, Buffalo, New York 14214 (United States)

    2011-07-15

    Purpose: Traditional computed tomography (CT) units provide a maximum scan field-of-view (sFOV) diameter of 50 cm and a limited bore size, which cannot accommodate a large patient habitus or an extended simulation setup in radiation therapy (RT). Wide-bore CT scanners with increased bore size were developed to address these needs. Some scanners have the capacity to reconstruct the CT images at an extended FOV (eFOV), through data interpolation or extrapolation, using projection data acquired with a conventional sFOV. Objects that extend past the sFOV for eFOV reconstruction may generate image artifacts resulting from truncated projection data; this may distort CT numbers and structure contours in the region beyond the sFOV. The purpose of this study was to evaluate the dosimetric impact of image artifacts from eFOV reconstruction with a wide-bore CT scanner in radiotherapy (RT) treatment planning. Methods: Testing phantoms (i.e., a mini CT phantom with equivalent tissue inserts, a set of CT normal phantoms and anthropomorphic phantoms of the thorax and the pelvis) were used to evaluate eFOV artifacts. Reference baseline images of these phantoms were acquired with the phantom centrally positioned within the sFOV. For comparison, the phantoms were then shifted laterally and scanned partially outside the sFOV, but still within the eFOV. Treatment plans were generated for the thoracic and pelvic anthropomorphic phantoms utilizing the Eclipse treatment planning system (TPS) to study the potential effects of eFOV artifacts on dose calculations. All dose calculations of baseline and test treatment plans were carried out using the same MU. Results: Results show that both body contour and CT numbers are altered by image artifacts in eFOV reconstruction. CT number distortions of up to -356 HU for bone tissue and up to 323 HU for lung tissue were observed in the mini CT phantom. Results from the large body normal phantom, which is close to a clinical patient size, show

  18. Wide-Scale Adoption of Photovoltaic Energy

    DEFF Research Database (Denmark)

    Yang, Yongheng; Enjeti, Prasad; Blaabjerg, Frede

    2015-01-01

    Current grid standards largely require that low-power (e.g., several kilowatts) single-phase photovoltaic (PV) systems operate at unity power factor (PF) with maximum power point tracking (MPPT), and disconnect from the grid under grid faults by means of islanding detection. However, in the case...... of wide-scale penetration of single-phase PV systems in the distributed grid, disconnection under grid faults can contribute to 1) voltage flickers, 2) power outages, and 3) system instability. This article explores grid code modifications for a wide-scale adoption of PV systems in the distribution grid....... In addition, based on the fact that Italy and Japan have recently undertaken a major review of standards for PV power conversion systems connected to low-voltage networks, the importance of low voltage ride-through (LVRT) for single-phase PV power systems under grid faults is considered, along with three...

  19. Analytical approximations for wide and narrow resonances

    International Nuclear Information System (INIS)

    Suster, Luis Carlos; Martinez, Aquilino Senra; Silva, Fernando Carvalho da

    2005-01-01

    This paper aims at developing analytical expressions for the adjoint neutron spectrum in the resonance energy region, taking into account both narrow and wide resonance approximations, in order to reduce the numerical computations involved. These analytical expressions, besides reducing computing time, are very simple from a mathematical point of view. The results obtained with this analytical formulation were compared to a reference solution obtained with a numerical method previously developed to solve the neutron balance adjoint equations. Narrow and wide resonances of U 238 were treated and the analytical procedure gave satisfactory results as compared with the reference solution, for the resonance energy range. The adjoint neutron spectrum is useful to determine the neutron resonance absorption, so that multigroup adjoint cross sections used by the adjoint diffusion equation can be obtained. (author)

  20. Analytical approximations for wide and narrow resonances

    Energy Technology Data Exchange (ETDEWEB)

    Suster, Luis Carlos; Martinez, Aquilino Senra; Silva, Fernando Carvalho da [Universidade Federal, Rio de Janeiro, RJ (Brazil). Coordenacao dos Programas de Pos-graduacao de Engenharia. Programa de Engenharia Nuclear]. E-mail: aquilino@lmp.ufrj.br

    2005-07-01

    This paper aims at developing analytical expressions for the adjoint neutron spectrum in the resonance energy region, taking into account both narrow and wide resonance approximations, in order to reduce the numerical computations involved. These analytical expressions, besides reducing computing time, are very simple from a mathematical point of view. The results obtained with this analytical formulation were compared to a reference solution obtained with a numerical method previously developed to solve the neutron balance adjoint equations. Narrow and wide resonances of U{sup 238} were treated and the analytical procedure gave satisfactory results as compared with the reference solution, for the resonance energy range. The adjoint neutron spectrum is useful to determine the neutron resonance absorption, so that multigroup adjoint cross sections used by the adjoint diffusion equation can be obtained. (author)

  1. Logarithmic circuit with wide dynamic range

    Science.gov (United States)

    Wiley, P. H.; Manus, E. A. (Inventor)

    1978-01-01

    A circuit deriving an output voltage that is proportional to the logarithm of a dc input voltage susceptible to wide variations in amplitude includes a constant current source which forward biases a diode so that the diode operates in the exponential portion of its voltage versus current characteristic, above its saturation current. The constant current source includes first and second, cascaded feedback, dc operational amplifiers connected in negative feedback circuit. An input terminal of the first amplifier is responsive to the input voltage. A circuit shunting the first amplifier output terminal includes a resistor in series with the diode. The voltage across the resistor is sensed at the input of the second dc operational feedback amplifier. The current flowing through the resistor is proportional to the input voltage over the wide range of variations in amplitude of the input voltage.

  2. Promoting and supporting PBL interests world wide

    DEFF Research Database (Denmark)

    Enemark, Stig; Kolmos, Anette; Moesby, Egon

    2006-01-01

    of projects world wide focusing on institutional change toward a more student centred, project organised, and problem based approach to learning. The Centre is also establishing a UCPBL Global Network on Problem Based Learning in order to facilitate better access to and co-operation within the PBL area.......-Based Learning (PBL) in Engineering Education, an increasing number of universities and engineering schools throughout the world are seeking consultancy and cooperation with Aalborg University. The establishment of UCPBL is therefore a timely opportunity to merge the efforts into one organisational structure...... aiming to promote and support PBL interests worldwide. This paper presents the UCPBL profile and plan of action. This includes a wide range of activities such as promoting research and development within the various PBL models and their implementation; Education and training in PBL through offering...

  3. Swell propagation across a wide continental shelf

    OpenAIRE

    Hendrickson, Eric J.

    1996-01-01

    The effects of wave refraction and damping on swell propagation across a wide continental shelf were examined with data from a transect of bottom pressure recorders extending from the beach to the shelf break near Duck, North Carolina. The observations generally show weak variations in swell energy across the shelf during benign conditions, in qualitative agreement with predictions of a spectral refraction model. Although the predicted ray trajectories are quite sensitive to the irregular she...

  4. PENYEBARAN INFORMASI MENGGUNAKAN WWW (WORLD WIDE WEB

    Directory of Open Access Journals (Sweden)

    Ika Atman Satya

    2011-12-01

    Full Text Available Media Informasi secara tradisional telah kita kenai dengan menggunakan koran, televisi, radio dan buku referensi. Media informasi tersebut untuk penyebarannya memerlukan penunjang agar informasi tersebut dapat disebarkan secara lutis. Selain penggunaan media tradisional tersebut penyebaran informasi dengan menggunakan jaringan komputer Internet juga berkembang. Salah satu cara penyebaran informasi dengan menggunakan aplikasi WWW (World Wide Web yang mempunyai kemampuan menggabungkan gambar, text dan suara secara interaktif. Pada tulisan ini akan dibahas tentang kemampuan, penggunaan dan pengembangan server WWW.

  5. Excessive current in wide superconducting films

    International Nuclear Information System (INIS)

    Volotskaya, V.G.; Sivakov, A.G.; Turutanov, O.G.

    1986-01-01

    The resistive state of a wide long film due to superconductivity destruction by current is studied. The voltage-independent excess current I 0 is observed on I-V curves at high transport currents. The two-dimensional image of the current-carrying sample obtained by laser scanning technique in this current range indicates that the whole film is in the resistive state. The current I 0 is measured as a function of magnetic field and SHF power

  6. Economics of area-wide pest control

    International Nuclear Information System (INIS)

    Mumford, J.D.

    2000-01-01

    Area-wide pest management is commonly practised throughout the world, probably much more so than is generally recognised (Lindquist 2000, Klassen 2000). Apart from highly publicised area-wide schemes such as the sterile insect technique (SIT) for fruit flies, pheromone disruption for cotton bollworms and classical biological control, there are many examples of actions such as concerted host plant eradication, enforced closed crop seasons, organised pesticide rotation for resistance management, coordination of resistant crop genotypes, etc., some going back several centuries, which should also be considered as area-wide practices. Each of these is faced with many of the economic issues generally associated with area-wide management which will be discussed below. In general, there are to be four major questions to answer in devising an area-wide pest management programme: 1) Should a particular pest be controlled locally or area-wide? 2) What is an appropriate area over which management should be attempted? 3) Within that area what form of control is most efficient? 4) What level of organisation should be used to get the job done? It should be noted that apart from clearly objective measures such as technical effectiveness (say, mortality) or cost efficiency (mortality per dollar), there are many subjective measures that come into the evaluation of area-wide control due to the element of risk (for example, in quarantine and eradication), the boundaries of externalities (for example, variable probabilities of pesticide drift under different conditions or target organism sensitivities) and time preferences for returns on capital investments (such as insect rearing facilities or research to develop pheromone technologies). As a result of these subjective components, it may sometimes be difficult to reach clearly agreed decisions based on objective economic analyses, even with a consensus on the data used. There are three general classes of economic problems in comparing

  7. Proceedings of wide band gap semiconductors

    International Nuclear Information System (INIS)

    Moustakas, T.D.; Pankove, J.I.; Hamakawa, Y.

    1992-01-01

    This book contains the proceedings of wide band gap semiconductors. Wide band gap semiconductors are under intense study because of their potential applications in photonic devices in the visible and ultraviolet part of the electromagnetic spectrum, and devices for high temperature, high frequency and high power electronics. Additionally, due to their unique mechanical, thermal, optical, chemical, and electronic properties many wide band gap semiconductors are anticipated to find applications in thermoelectric, electrooptic, piezoelectric and acoustooptic devices as well as protective coatings, hard coatings and heat sinks. Material systems covered in this symposium include diamond, II-VI compounds, III-V nitrides, silicon carbide, boron compounds, amorphous and microcrystalline semiconductors, chalcopyrites, oxides and halides. The various papers addressed recent experimental and theoretical developments. They covered issues related to crystal growth (bulk and thin films), structure and microstructure, defects, doping, optoelectronic properties and device applications. A theoretical session was dedicated to identifying common themes in the heteroepitaxy and the role of defects in doping, compensation and phase stability of this unique class of materials. Important experimental milestones included the demonstrations of bright blue injection luminescence at room temperatures from junctions based on III-V nitrides and a similar result from multiple quantum wells in a ZnSe double heterojunction at liquid nitrogen temperatures

  8. Widely distributed SEP events and pseudostreamers

    Science.gov (United States)

    Panasenco, O.; Panasenco, A.; Velli, M.

    2017-12-01

    Our analysis of the pseudostreamer magnetic topology reveals new interesting implications for understanding SEP acceleration in CMEs. The possible reasons for the wide distribution of some SEP events can be the presence of pseudostreamers in the vicinity of the SEP source region which creates conditions for the existence of strong longitudinal spread of energetic particles as well as an anomalous longitudinal solar wind magnetic field component. We reconstructed the 3D magnetic configurations of pseudostreamers with a potential field source surface (PFSS) model, which uses as a lower boundary condition the magnetic field derived from an evolving surface-flux transport model. In order to estimate the possible magnetic connections between the spacecraft and the SEP source region, we used the Parker spiral, ENLIL and PFSS models. We found that in cases of the wide SEP distributions a specific configuration of magnetic field appears to exist at low solar latitudes all the way around the sun, we named this phenomenon a pseudostreamers belt. It appears that the presence of the well developed pseudostreamer or, rather multiple pseudostreamers, organized into the pseudostreamer belt can be considered as a very favorable condition for wide SEP events.

  9. Calibration device for wide range monitor

    International Nuclear Information System (INIS)

    Kodoku, Masaya; Sato, Toshifumi.

    1989-01-01

    The calibration device for a wide range monitor according to the present invention can continuously calibrate the entire counting regions of a wide range monitor. The wide range monitor detect the reactor power in the neutron source region by means of a pulse counting method and detects the reactor power in the intermediate region by means of a cambell method. A calibration signal outputting means is disposed for continuously outputting, as such calibration signals, pulse number varying signals in which the number of pulses per unit time varies depending on the reactor power in the neutron source region to be simulated and amplitude square means varying signal in which the mean square value of amplitude varies depending on the reactor power in the intermediate region to be simulated. By using both of the calibration signals, calibration can be conducted for the nuclear reactor power in the neutron source region and the intermediate region even if the calibration is made over two regions, further, calibration for the period present over the two region can be conducted easily as well. (I.S.)

  10. THE SPITZER DEEP, WIDE-FIELD SURVEY

    International Nuclear Information System (INIS)

    Ashby, M. L. N.; Brodwin, M.; Stern, D.; Griffith, R.; Eisenhardt, P.; Gorjian, V.; Kozlowski, S.; Kochanek, C. S.; Bock, J. J.; Borys, C.; Brand, K.; Grogin, N. A.; Brown, M. J. I.; Cool, R.; Cooray, A.; Croft, S.; Dey, A.; Eisenstein, D.; Gonzalez, A. H.; Ivison, R. J.

    2009-01-01

    The Spitzer Deep, Wide-Field Survey (SDWFS) is a four-epoch infrared survey of 10 deg. 2 in the Booetes field of the NOAO Deep Wide-Field Survey using the IRAC instrument on the Spitzer Space Telescope. SDWFS, a Spitzer Cycle 4 Legacy project, occupies a unique position in the area-depth survey space defined by other Spitzer surveys. The four epochs that make up SDWFS permit-for the first time-the selection of infrared-variable and high proper motion objects over a wide field on timescales of years. Because of its large survey volume, SDWFS is sensitive to galaxies out to z ∼ 3 with relatively little impact from cosmic variance for all but the richest systems. The SDWFS data sets will thus be especially useful for characterizing galaxy evolution beyond z ∼ 1.5. This paper explains the SDWFS observing strategy and data processing, presents the SDWFS mosaics and source catalogs, and discusses some early scientific findings. The publicly released, full-depth catalogs contain 6.78, 5.23, 1.20, and 0.96 x 10 5 distinct sources detected to the average 5σ, 4''-diameter, aperture-corrected limits of 19.77, 18.83, 16.50, and 15.82 Vega mag at 3.6, 4.5, 5.8, and 8.0 μm, respectively. The SDWFS number counts and color-color distribution are consistent with other, earlier Spitzer surveys. At the 6 minute integration time of the SDWFS IRAC imaging, >50% of isolated Faint Images of the Radio Sky at Twenty cm radio sources and >80% of on-axis XBooetes sources are detected out to 8.0 μm. Finally, we present the four highest proper motion IRAC-selected sources identified from the multi-epoch imaging, two of which are likely field brown dwarfs of mid-T spectral class.

  11. WIRELESS MINE-WIDE TELECOMMUNICATIONS TECHNOLOGY

    Energy Technology Data Exchange (ETDEWEB)

    Zvi H. Meiksin

    2004-03-01

    A comprehensive mine-wide, two-way wireless voice and data communication system for the underground mining industry was developed. The system achieves energy savings through increased productivity and greater energy efficiency in meeting safety requirements within mines. The mine-wide system is comprised of two interfaced subsystems: a through-the-earth communications system and an in-mine communications system. The mine-wide system permits two-way communication among underground personnel and between underground and surface personnel. The system was designed, built, and commercialized. Several systems are in operation in underground mines in the United States. The use of these systems has proven they result in considerable energy savings. A system for tracking the location of vehicles and people within the mine was also developed, built and tested successfully. Transtek's systems are being used by the National Institute of Occupational Safety and Health (NIOSH) in their underground mine rescue team training program. This project also resulted in a spin-off rescue team lifeline and communications system. Furthermore, the project points the way to further developments that can lead to a GPS-like system for underground mines allowing the use of autonomous machines in underground mining operations, greatly reducing the amount of energy used in these operations. Some products developed under this program are transferable to applications in fields other than mining. The rescue team system is applicable to use by first responders to natural, accidental, or terrorist-caused building collapses. The in-mine communications system can be installed in high-rise buildings providing in-building communications to security and maintenance personnel as well as to first responders.

  12. Pickering Nuclear site wide groundwater monitoring system

    International Nuclear Information System (INIS)

    DeWilde, J.; Chin-Cheong, D.; Lledo, C.; Wootton, R.; Belanger, D.; Hansen, K.

    2001-01-01

    Ontario Power Generation Inc. (OPG) is continuing its efforts to understand the chemical and physical characteristics of the groundwater flow systems beneath the Pickering Nuclear Generating Station (PNGS). To this end, OPG constructed a site-wide Groundwater Monitoring System (GMS) at the PNGS to provide support to other ongoing environmental investigations and to provide a means to monitor current and future groundwater environmental issues. This paper will present the results of this work, including the development of a state-of-the-art data management system for storage and retrieval of environmental data for the site, which has applications for other power generation facilities. (author)

  13. Wide Strip Casting Technology of Magnesium Alloys

    Science.gov (United States)

    Park, W.-J.; Kim, J. J.; Kim, I. J.; Choo, D.

    Extensive investigations relating to the production of high performance and low cost magnesium sheet by strip casting have been performed for the application to automotive parts and electronic devices. Research on magnesium sheet production technology started in 2004 by Research Institute of Industrial Science and Technology (RIST) with support of Pohang Iron and Steel Company (POSCO). POSCO has completed the world's first plant to manufacture magnesium coil. Another big project in order to develop wide strip casting technology for the automotive applications of magnesium sheets was started in succession.

  14. Three-dimensional liquid flattened Luneburg lens with ultra-wide viewing angle and frequency band

    Science.gov (United States)

    Wu, Lingling; Tian, Xiaoyong; Yin, Ming; Li, Dichen; Tang, Yiping

    2013-08-01

    Traditional Luneburg lens is a dielectric spherical antenna. It can focus the incoming collimated electromagnetic waves on its spherical surface, which causes the incompatibility with the planar feeding and receiving devices. Furthermore, the difficulties in the fabrication process also limited its applications. In this paper, a three-dimensional flattened Luneburg lens with a field-of-view angle up to 180° has been realized based on a liquid medium approach and a 3D-printing process. The fabricated three-dimensional lens showed a broadband transmission characteristic from 12.4 GHz to 18 GHz. The performance of the proposed lens was demonstrated by simulation and experimental results.

  15. Kepler Observations and Asteroseismology of θ Cyg, the Brightest StarObservable in the Kepler Field of View

    DEFF Research Database (Denmark)

    Guzik, Joyce A.; Houdek, G.; Chaplin, W. J.

    2012-01-01

    -March 2011). We present analyses of the solar-like oscillations first discovered in the Q6 data [1, 2]. We use observational constraints from the literature and recent ground-based observations including angular diameters from optical interferometry in conjunction with the frequency data to derive stellar...... properties (e.g., mass, age, metallicity, extent of convection zones). We also discuss the prospects for detecting longer period gravity-mode pulsations as seen in gamma Doradus variable stars of spectral type A-F, given these constraints. With an effective temperature near 6500 K and near ‘solar’ element....... The calculated envelope convection zone depth depends on the element abundance mixtures adopted for the stellar models [2]. Asteroseismic studies of θ Cyg therefore have potential to shed light on the solar abundance problem [3, 4], as well as to put constraints on the presence and detectability of g...

  16. Arrested Pneumatization of the Sphenoid Sinus on Large Field-of-View Cone Beam Computed Tomography Studies

    Directory of Open Access Journals (Sweden)

    Mehrnaz Tahmasbi-Arashlow

    2015-05-01

    Full Text Available Arrested pneumatization of the sphenoid sinus is a normal anatomical variant. The aim of this report is to define cone beam computed tomography (CBCT characteristics of arrested pneumatization of sphenoid sinus in an effort to help differentiate it from invasive or lytic skull base lesions. Two cases are presented with incidental findings. Both studies, acquired for other diagnostic purposes, demonstrated unique osseous patterns that were eventually deemed to be anatomic variations in the absence of clinical signs and symptoms although the pattern of bone loss and remodeling was diagnosed as pneumatization of the sphenoid sinus by a panel of medical and maxillofacial radiologists following contrasted advanced imaging. It is important to differentiate arrested pneumatization of the sphenoid sinus from lesions, such as arachnoid granulations, acoustic neuroma, glioma, metastatic lesions, meningioma, or chordoma, to prevent unnecessary biopsies or exploratory surgeries that would consequently reduce treatment costs and alleviate anxiety in patients.

  17. Electronics for a prototype variable field of view PET camera using the PMT-quadrant-sharing detector array

    Science.gov (United States)

    Li, H.; Wong, Wai-Hoi; Zhang, N.; Wang, J.; Uribe, J.; Baghaei, H.; Yokoyama, S.

    1999-06-01

    Electronics for a prototype high-resolution PET camera with eight position-sensitive detector modules has been developed. Each module has 16 BGO (Bi/sub 4/Ge/sub 3/O/sub 12/) blocks (each block is composed of 49 crystals). The design goals are component and space reduction. The electronics is composed of five parts: front-end analog processing, digital position decoding, fast timing, coincidence processing and master data acquisition. The front-end analog circuit is a zone-based structure (each zone has 3/spl times/3 PMTs). Nine ADCs digitize integration signals of an active zone identified by eight trigger clusters; each cluster is composed of six photomultiplier tubes (PMTs). A trigger corresponding to a gamma ray is sent to a fast timing board to obtain a time-mark, and the nine digitized signals are passed to the position decoding board, where a real block (four PMTs) can be picked out from the zone for position decoding. Lookup tables are used for energy discrimination and to identify the gamma-hit crystal location. The coincidence board opens a 70-ns initial timing window, followed by two 20-ns true/accidental time-mark lookup table windows. The data output from the coincidence board can be acquired either in sinogram mode or in list mode with a Motorola/IRONICS VME-based system.

  18. The LAMOST spectroscopic survey of stars in the Kepler field of view: Activity indicators and stellar parameters

    Science.gov (United States)

    Molenda-Żakowicz, Joanna; Frasca, Antonio; De Cat, Peter; Catanzaro, Giovanni

    2017-09-01

    We summarize the results of the completed first round of the LAMOST-Kepler project, and describe the status of its on-going second round. As a result of the first round of this project, the atmospheric parameters (Teff, log g, and [Fe/H]), the spectral classification (spectral type and luminosity class), and the radial velocities (RV) have been measured for 51,385 stars. For 4031 stars, we were able to measure the projected rotational velocity, while the minimum detectable v sin i was 120 km s-1. For 8821 stars with more than one observation, we computed the χ-square probability that the detected RV variations have a random occurrence. Finally, we classified 442 stars as chromospherically active on the basis of the analysis of their Hα and Ca II-IRT fluxes. All our results have been obtained from the low-resolution (R ˜ 1800) spectroscopic observations acquired with the LAMOST instrument. Based on observations collected with the Large Sky Area Multi-Object Fiber Spectroscopic Telescope (LAMOST) located at the Xinglong Observatory, China.

  19. Measurements on pointing error and field of view of Cimel-318 Sun photometers in the scope of AERONET

    Directory of Open Access Journals (Sweden)

    B. Torres

    2013-08-01

    Full Text Available Sensitivity studies indicate that among the diverse error sources of ground-based sky radiometer observations, the pointing error plays an important role in the correct retrieval of aerosol properties. The accurate pointing is specially critical for the characterization of desert dust aerosol. The present work relies on the analysis of two new measurement procedures (cross and matrix specifically designed for the evaluation of the pointing error in the standard instrument of the Aerosol Robotic Network (AERONET, the Cimel CE-318 Sun photometer. The first part of the analysis contains a preliminary study whose results conclude on the need of a Sun movement correction for an accurate evaluation of the pointing error from both new measurements. Once this correction is applied, both measurements show equivalent results with differences under 0.01° in the pointing error estimations. The second part of the analysis includes the incorporation of the cross procedure in the AERONET routine measurement protocol in order to monitor the pointing error in field instruments. The pointing error was evaluated using the data collected for more than a year, in 7 Sun photometers belonging to AERONET sites. The registered pointing error values were generally smaller than 0.1°, though in some instruments values up to 0.3° have been observed. Moreover, the pointing error analysis shows that this measurement can be useful to detect mechanical problems in the robots or dirtiness in the 4-quadrant detector used to track the Sun. Specifically, these mechanical faults can be detected due to the stable behavior of the values over time and vs. the solar zenith angle. Finally, the matrix procedure can be used to derive the value of the solid view angle of the instruments. The methodology has been implemented and applied for the characterization of 5 Sun photometers. To validate the method, a comparison with solid angles obtained from the vicarious calibration method was developed. The differences between both techniques are below 3%.

  20. Increasing the field-of-view of row–column-addressed ultrasound transducers: implementation of a diverging compound lens

    DEFF Research Database (Denmark)

    Engholm, Mathias; Beers, Christopher; Bouzari, Hamed

    2018-01-01

    was fabricated of a Bi2O3 loaded RTV615 and an unloaded Hapflex 541. The lens was tested using a RCA probe, and a FOV of 32.2° was measured from water tank tests, while the FEM model yielded 33.4°. A wire phantom with 0.15 mm diameter wires was imaged at 3 MHz down to a depth of 14 cm using a synthetic aperture...... imaging sequence with single element transmissions. The beamformed image showed that wires outside the array footprint were visible, demonstrating the increased FOV....

  1. Development of a High Irradiance LED Configuration for Small Field of View Motion Estimation of Fertilizer Particles

    Directory of Open Access Journals (Sweden)

    Simon Cool

    2015-11-01

    Full Text Available Better characterization of the fertilizer spreading process, especially the fertilizer pattern distribution on the ground, requires an accurate measurement of individual particle properties and dynamics. Both 2D and 3D high speed imaging techniques have been developed for this purpose. To maximize the accuracy of the predictions, a specific illumination level is required. This paper describes the development of a high irradiance LED system for high speed motion estimation of fertilizer particles. A spectral sensitivity factor was used to select the optimal LED in relation to the used camera from a range of commercially available high power LEDs. A multiple objective genetic algorithm was used to find the optimal configuration of LEDs resulting in the most homogeneous irradiance in the target area. Simulations were carried out for different lenses and number of LEDs. The chosen configuration resulted in an average irradiance level of 452 W/m2 with coefficient of variation less than 2%. The algorithm proved superior and more flexible to other approaches reported in the literature and can be used for various other applications.

  2. Wide-field high-performance geosynchronous imaging

    International Nuclear Information System (INIS)

    Wood, H. John; Jenstrom, Del; Wilson, Mark; Hinkal, Sanford; Kirchman, Frank

    1998-01-01

    The NASA Mission to Planet Earth (MTPE) Program and the National Oceanographic and Atmospheric Administration (NOAA) are sponsoring the Advanced Geosynchronous Studies (AGS) to develop technologies and system concepts for Earth observation from geosynchronous orbit. This series of studies is intended to benefit both MTPE science and the NOAA GOES Program. Within the AGS program, advanced imager trade studies have investigated two candidate concepts for near-term advanced geosynchronous imagers. One concept uses a scan mirror to direct the line of sight from a 3-axis stabilized platform. Another eliminates the need for a scan mirror by using an agile spacecraft bus to scan the entire instrument. The purpose of this paper is to discuss the optical design trades and system issues encountered in evaluating the two scanning approaches. The imager design started with a look at first principles: what is the most efficient way to image the Earth in those numerous spectral bands of interest to MTPE scientists and NOAA weather forecasters. Optical design trades included rotating filter wheels and dispersive grating instruments. The design converged on a bandpass filter instrument using four focal planes to cover the spectral range 0.45 to 13.0 micrometers. The first imager design uses a small agile spacecraft supporting an afocal optical telescope. Dichroic beamsplitters feed refractive objectives to four focal planes. The detectors are a series of long linear and rectangular arrays which are scanned in a raster fashion over the 17 degree Earth image. The use of the spacecraft attitude control system to raster the imager field-of-view (FOV) back and forth over the Earth eliminates the need for a scan mirror. However, the price paid is significant energy and time required to reverse the spacecraft slew motions at the end of each scan line. Hence, it is desired to minimize the number of scan lines needed to cover the full Earth disk. This desire, coupled with the ground

  3. A Wide-Field Photometric Survey for Extratidal Tails Around Five Metal-Poor Globular Clusters in the Galactic Halo

    Science.gov (United States)

    Chun, Sang-Hyun; Kim, Jae-Woo; Sohn, Sangmo T.; Park, Jang-Hyun; Han, Wonyong; Kim, Ho-Il; Lee, Young-Wook; Lee, Myung Gyoon; Lee, Sang-Gak; Sohn, Young-Jong

    2010-02-01

    Wide-field deep g'r'i' images obtained with the Megacam of the Canada-France-Hawaii Telescope are used to investigate the spatial configuration of stars around five metal-poor globular clusters M15, M30, M53, NGC 5053, and NGC 5466, in a field-of-view ~3°. Applying a mask filtering algorithm to the color-magnitude diagrams of the observed stars, we sorted cluster's member star candidates that are used to examine the characteristics of the spatial stellar distribution surrounding the target clusters. The smoothed surface density maps and the overlaid isodensity contours indicate that all of the five metal-poor globular clusters exhibit strong evidence of extratidal overdensity features over their tidal radii, in the form of extended tidal tails around the clusters. The orientations of the observed extratidal features show signatures of tidal tails tracing the clusters' orbits, inferred from their proper motions, and effects of dynamical interactions with the Galaxy. Our findings include detections of a tidal bridge-like feature and an envelope structure around the pair of globular clusters M53 and NGC 5053. The observed radial surface density profiles of target clusters have a deviation from theoretical King models, for which the profiles show a break at 0.5-0.7rt , extending the overdensity features out to 1.5-2rt . Both radial surface density profiles for different angular sections and azimuthal number density profiles confirm the overdensity features of tidal tails around the five metal-poor globular clusters. Our results add further observational evidence that the observed metal-poor halo globular clusters originate from an accreted satellite system, indicative of the merging scenario of the formation of the Galactic halo. Based on observations carried out at the Canada-France-Hawaii Telescope, operated by the National Research Council of Canada, the Centre National de la Recherche Scientifique de France, and the University of Hawaii. This is part of the

  4. FGWAS: Functional genome wide association analysis.

    Science.gov (United States)

    Huang, Chao; Thompson, Paul; Wang, Yalin; Yu, Yang; Zhang, Jingwen; Kong, Dehan; Colen, Rivka R; Knickmeyer, Rebecca C; Zhu, Hongtu

    2017-10-01

    Functional phenotypes (e.g., subcortical surface representation), which commonly arise in imaging genetic studies, have been used to detect putative genes for complexly inherited neuropsychiatric and neurodegenerative disorders. However, existing statistical methods largely ignore the functional features (e.g., functional smoothness and correlation). The aim of this paper is to develop a functional genome-wide association analysis (FGWAS) framework to efficiently carry out whole-genome analyses of functional phenotypes. FGWAS consists of three components: a multivariate varying coefficient model, a global sure independence screening procedure, and a test procedure. Compared with the standard multivariate regression model, the multivariate varying coefficient model explicitly models the functional features of functional phenotypes through the integration of smooth coefficient functions and functional principal component analysis. Statistically, compared with existing methods for genome-wide association studies (GWAS), FGWAS can substantially boost the detection power for discovering important genetic variants influencing brain structure and function. Simulation studies show that FGWAS outperforms existing GWAS methods for searching sparse signals in an extremely large search space, while controlling for the family-wise error rate. We have successfully applied FGWAS to large-scale analysis of data from the Alzheimer's Disease Neuroimaging Initiative for 708 subjects, 30,000 vertices on the left and right hippocampal surfaces, and 501,584 SNPs. Copyright © 2017 Elsevier Inc. All rights reserved.

  5. Review of stellarator research world wide

    International Nuclear Information System (INIS)

    Shonet, J.L.

    1987-01-01

    The world-wide effort in stellarators has evolved considerably during the past few years. Stellarator facilities are located in the Australia, Federal Republic of Germany, Japan, the Soviet Union, Spain, the United Kingdom and the United States. Dimensions of stellarators range from less than 20 centimeters in major radius to more than 2 meters, and magnetic field values between 0.2 Tesla to more than 3.0 Tesla. Stellarators are made in a variety of magnetic configurations with wide ranges of toroidal aspect ratios and methods of generating the stellarator magnetic surfaces. In particular, continuous helical coils, twisted modular coils, or twisted vacuum chambers all provide different means to generate nested toroidal magnetic surfaces without the need for currents flowing in the plasma. The goal of present day experiments is to accumulate a physics data base. This is being done by increasing electron and ion temperatures with non-ohmic heating, by transport and scaling studies considering neoclassical scaling, global scaling, effects of electric fields, the bootstrap current and magnetic islands. Higher betas are being attempted by designing suitable magnetic configurations, pellet injection and/or minimizing transport losses. Plasma-wall interactions and particle control are being examined by divertor, pumped-limiter and carbonization experiments

  6. Wide-field synovial fluid imaging using polarized lens-free on-chip microscopy for point-of-care diagnostics of gout (Conference Presentation)

    Science.gov (United States)

    Zhang, Yibo; Lee, Seung Yoon; Zhang, Yun; Furst, Daniel; Fitzgerald, John; Ozcan, Aydogan

    2016-03-01

    Gout and pseudogout are forms of crystal arthropathy caused by monosodium urate (MSU) and calcium pyrophosphate dehydrate (CPPD) crystals in the joint, respectively, that can result in painful joints. Detecting the unique-shaped, birefringent MSU/CPPD crystals in a synovial fluid sample using a compensated polarizing microscope has been the gold-standard for diagnosis since the 1960's. However, this can be time-consuming and inaccurate, especially if there are only few crystals in the fluid. The high-cost and bulkiness of conventional microscopes can also be limiting for point-of-care diagnosis. Lens-free on-chip microscopy based on digital holography routinely achieves high-throughput and high-resolution imaging in a cost-effective and field-portable design. Here we demonstrate, for the first time, polarized lens-free on-chip imaging of MSU and CPPD crystals over a wide field-of-view (FOV ~ 20.5 mm2, i.e., gout and pseudogout. Circularly polarizer partially-coherent light is used to illuminate the synovial fluid sample on a glass slide, after which a quarter-wave-plate and an angle-mismatched linear polarizer are used to analyze the transmitted light. Two lens-free holograms of the MSU/CPPD sample are taken, with the sample rotated by 90°, to rule out any non-birefringent objects within the specimen. A phase-recovery algorithm is also used to improve the reconstruction quality, and digital pseudo-coloring is utilized to match the color and contrast of the lens-free image to that of a gold-standard microscope image to ease the examination by a rheumatologist or a laboratory technician, and to facilitate computerized analysis.

  7. WISE: The Wide-field Infrared Survey Explorer

    Science.gov (United States)

    Eisenhardt, Peter R.; Wright, E. L.; Benford, D.; Blain, A.; Cohen, M.; Cutri, R.; Gautier, T. N.; Jarrett, T.; Kirkpatrick, J. D.; Leisawitz, D.; Lonsdale, C.; Mainzer, A.; Mather, J.; McLean, I.; McMillan, R.; Mendez, B.; Padgett, D.; Ressler, M.; Skrutskie, M.; Stanford, S. A.; Walker, R.

    2009-01-01

    WISE will map the entire sky at 3.3, 4.7, 12 and 23 microns with sensitivities of 0.12, 0.16. 0.65, and 2.6 mJy. WISE will find the most luminous galaxies in the universe, the closest stars to the Sun, and detect most main belt asteroids larger than 3 km. WISE will be placed into a Sun-synchronous polar orbit on a Delta 7320-10 rocket, rotating at a constant rate while a scan mirror freezes the line of sight during each exposure, covering the sky in 6 months following a one month checkout. Orbit to orbit overlap provides 8 or more exposures at each location. The instrument, provided by the Space Dynamics Laboratory, includes an all-reflective aluminum telescope with a 40 cm primary built by SSG-Tinsley, a solid hydrogen cryostat built by Lockheed-Martin's Advanced Technology Center, and 1024x1024 pixel Si:As and HgCdTe arrays built by DRS and Teledyne. Dichroic beamsplitters allow simultaneous images in the four bands over a 47'x47' field of view with 5" resolution to be obtained every 11 seconds. Ball Aerospace is providing the spacecraft, including a 500W fixed solar array, Li-ion battery, two star trackers, reaction wheels, and torque rods. The 50 GB per day of images are losslessly compressed, stored in flash memory, and downlinked at 100 Mbps four times per day using a fixed antenna and TDRSS satellites. The Infrared Processing and Analysis Center will process the data and deliver the image atlas and source catalog, with a preliminary release 6 months after the survey, and a final release 2 years after the survey. JPL manages the project for UCLA PI Ned Wright, and conducts mission operations. Education and Public Outreach is provided by UC Berkeley's Space Science Laboratory. WISE hardware is presently being integrated and tested, with launch scheduled in November 2009.

  8. Wide-field optical detection of nanoparticles using on-chip microscopy and self-assembled nanolenses

    Science.gov (United States)

    Mudanyali, Onur; McLeod, Euan; Luo, Wei; Greenbaum, Alon; Coskun, Ahmet F.; Hennequin, Yves; Allier, Cédric P.; Ozcan, Aydogan

    2013-03-01

    The direct observation of nanoscale objects is a challenging task for optical microscopy because the scattering from an individual nanoparticle is typically weak at optical wavelengths. Electron microscopy therefore remains one of the gold standard visualization methods for nanoparticles, despite its high cost, limited throughput and restricted field-of-view. Here, we describe a high-throughput, on-chip detection scheme that uses biocompatible wetting films to self-assemble aspheric liquid nanolenses around individual nanoparticles to enhance the contrast between the scattered and background light. We model the effect of the nanolens as a spatial phase mask centred on the particle and show that the holographic diffraction pattern of this effective phase mask allows detection of sub-100 nm particles across a large field-of-view of >20 mm2. As a proof-of-concept demonstration, we report on-chip detection of individual polystyrene nanoparticles, adenoviruses and influenza A (H1N1) viral particles.

  9. [Wide QRS tachycardia preceded by pacemaker spikes].

    Science.gov (United States)

    Romero, M; Aranda, A; Gómez, F J; Jurado, A

    2014-04-01

    The differential diagnosis and therapeutic management of wide QRS tachycardia preceded by pacemaker spike is presented. The pacemaker-mediated tachycardia, tachycardia fibrillo-flutter in patients with pacemakers, and runaway pacemakers, have a similar surface electrocardiogram, but respond to different therapeutic measures. The tachycardia response to the application of a magnet over the pacemaker could help in the differential diagnosis, and in some cases will be therapeutic, as in the case of a tachycardia-mediated pacemaker. Although these conditions are diagnosed and treated in hospitals with catheterization laboratories using the application programmer over the pacemaker, patients presenting in primary care clinic and emergency forced us to make a diagnosis and treat the haemodynamically unstable patient prior to referral. Copyright © 2012 Sociedad Española de Médicos de Atención Primaria (SEMERGEN). Publicado por Elsevier España. All rights reserved.

  10. Genome-wide Analysis of Gene Regulation

    DEFF Research Database (Denmark)

    Chen, Yun

    to protein: through epigenetic modifications, transcription regulators or post-transcriptional controls. The following papers concern several layers of gene regulation with questions answered by different HTS approaches. Genome-wide screening of epigenetic changes by ChIP-seq allowed us to study both spatial...... and temporal alterations of histone modifications (Papers I and II). Coupling the data with machine learning approaches, we established a prediction framework to assess the most informative histone marks as well as their most influential nucleosome positions in predicting the promoter usages. (Papers I...... they regulated or if the sites had global elevated usage rates by multiple TFs. Using RNA-seq, 5’end-seq in combination with depletion of 5’exonuclease as well as nonsensemediated decay (NMD) factors, we systematically analyzed NMD substrates as well as their degradation intermediates in human cells (Paper V...

  11. World-Wide Web the information universe

    CERN Document Server

    Berners-Lee, Tim; Groff, Jean-Francois; Pollermann, Bernd

    1992-01-01

    Purpose - The World-Wide Web (W-3) initiative is a practical project designed to bring a global information universe into existence using available technology. This paper seeks to describe the aims, data model, and protocols needed to implement the "web" and to compare them with various contemporary systems. Design/methodology/approach - Since Vannevar Bush's article, men have dreamed of extending their intellect by making their collective knowledge available to each individual by using machines. Computers provide us two practical techniques for human-knowledge interface. One is hypertext, in which links between pieces of text (or other media) mimic human association of ideas. The other is text retrieval, which allows associations to be deduced from the content of text. The W-3 ideal world allows both operations and provides access from any browsing platform. Findings - Various server gateways to other information systems have been produced, and the total amount of information available on the web is...

  12. Plant Wide Assessment for SIFCO Industries, Inc.

    Energy Technology Data Exchange (ETDEWEB)

    Kelly Kissock, Arvind Thekdi et. al.

    2005-07-06

    Sifco Industries carreid out a plant wide energy assessment under a collaborative program with the U.S. Department of Energy during October 2004 to September 2005. During the year, personnel from EIS, E3M, DPS, BuyCastings.Com, and Sifco plant facilities and maintenance personnel, as a team collected energy use, construction, process, equipment and operational information about the plant. Based on this information, the team identified 13 energy savings opportunities. Near term savings opportunities have a total potential savings of about $1,329,000 per year and a combined simple payback of about 11 months. Implementation of these recommendations would reduce CO2 emissions by about 16,000,000 pounds per year, which would reduce overall plant CO2 emissions by about 45%. These totals do not include another $830,000 per year in potential savings with an estimated 9-month payback, from converting the forging hammers from steam to compressed air.

  13. Wide Angle Michelson Doppler Imaging Interferometer (WAMDII)

    Science.gov (United States)

    Roberts, B.

    1986-01-01

    The wide angle Michelson Doppler imaging interferometer (WAMDII) is a specialized type of optical Michelson interferometer working at sufficiently long path difference to measure Doppler shifts and to infer Doppler line widths of naturally occurring upper atmospheric Gaussian line emissions. The instrument is intended to measure vertical profiles of atmospheric winds and temperatures within the altitude range of 85 km to 300 km. The WAMDII consists of a Michelson interferometer followed by a camera lens and an 85 x 106 charge coupled device photodiode array. Narrow band filters in a filter wheel are used to isolate individual line emissions and the lens forms an image of the emitting region on the charge coupled device array.

  14. Mathematical Formalism for Designing Wide-Field X-Ray Telescopes: Mirror Nodal Positions and Detector Tilts

    Science.gov (United States)

    Elsner, R. F.; O'Dell, S. L.; Ramsey, B. D.; Weisskopf, M. C.

    2011-01-01

    We provide a mathematical formalism for optimizing the mirror nodal positions along the optical axis and the tilt of a commonly employed detector configuration at the focus of a x-ray telescope consisting of nested mirror shells with known mirror surface prescriptions. We adopt the spatial resolution averaged over the field-of-view as the figure of merit M. A more complete description appears in our paper in these proceedings.

  15. Community wide interventions for increasing physical activity.

    Science.gov (United States)

    Baker, Philip R A; Francis, Daniel P; Soares, Jesus; Weightman, Alison L; Foster, Charles

    2015-01-05

    Multi-strategic community wide interventions for physical activity are increasingly popular but their ability to achieve population level improvements is unknown. To evaluate the effects of community wide, multi-strategic interventions upon population levels of physical activity. We searched the Cochrane Public Health Group Segment of the Cochrane Register of Studies,The Cochrane Library, MEDLINE, MEDLINE in Process, EMBASE, CINAHL, LILACS, PsycINFO, ASSIA, the British Nursing Index, Chinese CNKI databases, EPPI Centre (DoPHER, TRoPHI), ERIC, HMIC, Sociological Abstracts, SPORT Discus, Transport Database and Web of Science (Science Citation Index, Social Sciences Citation Index, Conference Proceedings Citation Index). We also scanned websites of the EU Platform on Diet, Physical Activity and Health; Health-Evidence.org; the International Union for Health Promotion and Education; the NIHR Coordinating Centre for Health Technology (NCCHTA); the US Centre for Disease Control and Prevention (CDC) and NICE and SIGN guidelines. Reference lists of all relevant systematic reviews, guidelines and primary studies were searched and we contacted experts in the field. The searches were updated to 16 January 2014, unrestricted by language or publication status. Cluster randomised controlled trials, randomised controlled trials, quasi-experimental designs which used a control population for comparison, interrupted time-series studies, and prospective controlled cohort studies were included. Only studies with a minimum six-month follow up from the start of the intervention to measurement of outcomes were included. Community wide interventions had to comprise at least two broad strategies aimed at physical activity for the whole population. Studies which randomised individuals from the same community were excluded. At least two review authors independently extracted the data and assessed the risk of bias. Each study was assessed for the setting, the number of included components

  16. Generalization of the Wide-Sense Markov Concept to a Widely Linear Processing

    International Nuclear Information System (INIS)

    Espinosa-Pulido, Juan Antonio; Navarro-Moreno, Jesús; Fernández-Alcalá, Rosa María; Ruiz-Molina, Juan Carlos; Oya-Lechuga, Antonia; Ruiz-Fuentes, Nuria

    2014-01-01

    In this paper we show that the classical definition and the associated characterizations of wide-sense Markov (WSM) signals are not valid for improper complex signals. For that, we propose an extension of the concept of WSM to a widely linear (WL) setting and the study of new characterizations. Specifically, we introduce a new class of signals, called widely linear Markov (WLM) signals, and we analyze some of their properties based either on second-order properties or on state-space models from a WL processing standpoint. The study is performed in both the forwards and backwards directions of time. Thus, we provide two forwards and backwards Markovian representations for WLM signals. Finally, different estimation recursive algorithms are obtained for these models

  17. Traffic Flow Wide-Area Surveillance system

    Energy Technology Data Exchange (ETDEWEB)

    Allgood, G.O.; Ferrell, R.K.; Kercel, S.W.; Abston, R.A.

    1994-09-01

    Traffic management can be thought of as a stochastic queuing process where the serving time at one of its control points is dynamically linked to the global traffic pattern, which is, in turn, dynamically linked to the control point. For this closed-loop system to be effective, the traffic management system must sense and interpret a large spatial projection of data originating from multiple sensor suites. This concept is the basis for the development of a Traffic Flow Wide-Area Surveillance (TFWAS) system. This paper presents the results of a study by Oak Ridge National Laboratory to define the operational specifications and characteristics, to determine the constraints, and to examine the state of technology of a TFWAS system in terms of traffic management and control. In doing so, the functions and attributes of a TFWAS system are mapped into an operational structure consistent with the Intelligent Vehicle Highway System (IVHS) concept and the existing highway infrastructure. This mapping includes identifying candidate sensor suites and establishing criteria, requirements, and performance measures by which these systems can be graded in their ability and practicality to meet the operational requirements of a TFWAS system. In light of this, issues such as system integration, applicable technologies, impact on traffic management and control, and public acceptance are addressed.

  18. Golden Jubilee Photos: World Wide Web

    CERN Multimedia

    2004-01-01

    At the end of the 1980s, the Internet was already a valuable tool to scientists, allowing them to exchange e-mails and to access powerful computers remotely. A more simple means of sharing information was needed, however, and CERN, with its long tradition of informatics and networking, was the ideal place to find it. Moreover, hundreds of scientists from all over the world were starting to work together on preparations for the experiments at the Large Electron-Positron (LEP) collider. In 1989, Tim Berners-Lee (see photo), a young scientist working at CERN, drafted a proposal for an information-management system combining the internet, personal computers and computer-aided document consultation, known as hypertext. In 1990 he was joined by Robert Cailliau and the weaving of the World Wide Web began in earnest, even though only two CERN computers were allocated to the task at the time. The Web subsequently underwent a steady expansion to include the world's main particle physics institutes. The Web was not the...

  19. Bitcoin – the World-Wide Currency

    Directory of Open Access Journals (Sweden)

    Shuba Olena А.

    2017-11-01

    Full Text Available The article is aimed at researching bitcoin, the digital currency. It has been found that Bitcoin is a cryptocurrency, that is, the virtual money, which has no material equivalent. The history of creation and development of cryptocurrency was reviewed. There is a reduction in volatility, which guarantees the security of currency, as well as the increase in currency volume and the inability to estimate the profitability of bitcoins. The dynamics of the value of digital currency in US dollars over recent years has been analyzed. Improvement of attitude of many countries to the considered cryptocurrency, in particular the USA, Germany, Spain, Canada, Australia, Israel and Scandinavian countries has been identified. The reasons of Ukraine’s interest in Bitcoin have been considered. Possibilities of creation of cryptocurrency on the territory of Ukraine have been analyzed, i.e. cost of electricity for mining, the legal status of mining firms, and the attitude of the National Bank of Ukraine to the digital currency. It has been concluded that the recognition of Bitcoin by the world countries in the future will allow it to be granted the status of world-wide currency.

  20. Metasurface Enabled Wide-Angle Fourier Lens.

    Science.gov (United States)

    Liu, Wenwei; Li, Zhancheng; Cheng, Hua; Tang, Chengchun; Li, Junjie; Zhang, Shuang; Chen, Shuqi; Tian, Jianguo

    2018-06-01

    Fourier optics, the principle of using Fourier transformation to understand the functionalities of optical elements, lies at the heart of modern optics, and it has been widely applied to optical information processing, imaging, holography, etc. While a simple thin lens is capable of resolving Fourier components of an arbitrary optical wavefront, its operation is limited to near normal light incidence, i.e., the paraxial approximation, which puts a severe constraint on the resolvable Fourier domain. As a result, high-order Fourier components are lost, resulting in extinction of high-resolution information of an image. Other high numerical aperture Fourier lenses usually suffer from the bulky size and costly designs. Here, a dielectric metasurface consisting of high-aspect-ratio silicon waveguide array is demonstrated experimentally, which is capable of performing 1D Fourier transform for a large incident angle range and a broad operating bandwidth. Thus, the device significantly expands the operational Fourier space, benefitting from the large numerical aperture and negligible angular dispersion at large incident angles. The Fourier metasurface will not only facilitate efficient manipulation of spatial spectrum of free-space optical wavefront, but also be readily integrated into micro-optical platforms due to its compact size. © 2018 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  1. Community wide interventions for increasing physical activity.

    Science.gov (United States)

    Baker, Philip Ra; Francis, Daniel P; Soares, Jesus; Weightman, Alison L; Foster, Charles

    2011-04-13

    Multi-strategic community wide interventions for physical activity are increasingly popular but their ability to achieve population level improvements is unknown. To evaluate the effects of community wide, multi-strategic interventions upon population levels of physical activity. We searched the Cochrane Public Health Group Specialised Register, The Cochrane Library, MEDLINE, MEDLINE in Process, EMBASE, CINAHL, LILACS, PsycINFO, ASSIA, The British Nursing Index, Chinese CNKI databases, EPPI Centre (DoPHER, TRoPHI), ERIC, HMIC, Sociological Abstracts, SPORTDiscus, Transport Database and Web of Science (Science Citation Index, Social Sciences Citation Index, Conference Proceedings Citation Index). We also scanned websites of the EU Platform on Diet, Physical Activity and Health; Health-Evidence.ca; the International Union for Health Promotion and Education; the NIHR Coordinating Centre for Health Technology (NCCHTA) and NICE and SIGN guidelines. Reference lists of all relevant systematic reviews, guidelines and primary studies were followed up. We contacted experts in the field from the National Obesity Observatory Oxford, Oxford University; Queensland Health, Queensland University of Technology, the University of Central Queensland; the University of Tennessee and Washington University; and handsearched six relevant journals. The searches were last updated to the end of November 2009 and were not restricted by language or publication status. Cluster randomised controlled trials, randomised controlled trials (RCT), quasi-experimental designs which used a control population for comparison, interrupted time-series (ITS) studies, and prospective controlled cohort studies (PCCS) were included. Only studies with a minimum six-month follow up from the start of the intervention to measurement of outcomes were included. Community wide interventions had to comprise at least two broad strategies aimed at physical activity for the whole population. Studies which randomised

  2. Natural background radiation exposures world-wide

    International Nuclear Information System (INIS)

    Bennett, B.G.

    1993-01-01

    The average radiation dose to the world's population from natural radiation sources has been assessed by UNSCEAR to be 2.4 mSv per year. The components of this exposure, methods of evaluation and, in particular, the variations in the natural background levels are presented in this paper. Exposures to cosmic radiation range from 0.26 mSv per year at sea level to 20 times more at an altitude of 6000 m. Exposures to cosmogenic radionuclides ( 3 H, 14 C) are relatively insignificant and little variable. The terrestrial radionuclides 40 K, 238 U, and 232 Th and the decay products of the latter two constitute the remainder of the natural radiation exposure. Wide variations in exposure occur for these components, particularly for radon and its decay products, which can accumulate to relatively high levels indoors. Unusually high exposures to uranium and thorium series radionuclides characterize the high natural background areas which occur in several localized regions in the world. Extreme values in natural radiation exposures have been estimated to range up to 100 times the average values. (author). 15 refs, 3 tabs

  3. Traffic flow wide-area surveillance system

    Science.gov (United States)

    Allgood, Glenn O.; Ferrell, Regina K.; Kercel, Stephen W.; Abston, Ruth A.

    1995-01-01

    Traffic management can be thought of as a stochastic queuing process where the serving time at one of its control points is dynamically linked to the global traffic pattern, which is, in turn, dynamically linked to the control point. For this closed-loop system to be effective, the traffic management system must sense and interpret a large spatial projection of data originating from multiple sensor suites. This concept is the basis for the development of a traffic flow wide-area surveillance (TFWAS) system. This paper presents the results of a study by Oak Ridge National Laboratory to define the operational specifications and characteristics, to determine the constraints, and to examine the state of technology of a TFWAS system in terms of traffic management and control. In doing so, the functions and attributes of a TFWAS system are mapped into an operational structure consistent with the Intelligent Vehicle Highway System (IVHS) concept and the existing highway infrastructure. This mapping includes identifying candidate sensor suites and establishing criteria, requirements, and performance measures by which these systems can be graded in their ability and practicality to meet the operational requirements of a TFWAS system. In light of this, issues such as system integration, applicable technologies, impact on traffic management and control, and public acceptance are addressed.

  4. World Wide Web of Your Wide Web? Juridische aspecten van zoekmachine-personalisatie

    NARCIS (Netherlands)

    Oostveen, M.

    2012-01-01

    Het world wide web is een enorme bron van informatie. Iedere internetgebruiker maakt gebruik van zoekmachines om die informatie te kunnen vinden. Veel gebruikers weten echter niet dat zoekresultaten behorende bij een bepaalde zoekterm niet voor iedereen hetzelfde zijn. Dit personaliseren van

  5. Genome wide selection in Citrus breeding.

    Science.gov (United States)

    Gois, I B; Borém, A; Cristofani-Yaly, M; de Resende, M D V; Azevedo, C F; Bastianel, M; Novelli, V M; Machado, M A

    2016-10-17

    Genome wide selection (GWS) is essential for the genetic improvement of perennial species such as Citrus because of its ability to increase gain per unit time and to enable the efficient selection of characteristics with low heritability. This study assessed GWS efficiency in a population of Citrus and compared it with selection based on phenotypic data. A total of 180 individual trees from a cross between Pera sweet orange (Citrus sinensis Osbeck) and Murcott tangor (Citrus sinensis Osbeck x Citrus reticulata Blanco) were evaluated for 10 characteristics related to fruit quality. The hybrids were genotyped using 5287 DArT_seq TM (diversity arrays technology) molecular markers and their effects on phenotypes were predicted using the random regression - best linear unbiased predictor (rr-BLUP) method. The predictive ability, prediction bias, and accuracy of GWS were estimated to verify its effectiveness for phenotype prediction. The proportion of genetic variance explained by the markers was also computed. The heritability of the traits, as determined by markers, was 16-28%. The predictive ability of these markers ranged from 0.53 to 0.64, and the regression coefficients between predicted and observed phenotypes were close to unity. Over 35% of the genetic variance was accounted for by the markers. Accuracy estimates with GWS were lower than those obtained by phenotypic analysis; however, GWS was superior in terms of genetic gain per unit time. Thus, GWS may be useful for Citrus breeding as it can predict phenotypes early and accurately, and reduce the length of the selection cycle. This study demonstrates the feasibility of genomic selection in Citrus.

  6. Wide Bandgap Semiconductor Opportunities in Power Electronics

    Energy Technology Data Exchange (ETDEWEB)

    Das, Sujit [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Marlino, Laura D. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Armstrong, Kristina O. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States)

    2018-01-01

    The report objective is to explore the Wide Bandgap (WBG) Power Electronics (PE) market, applications, and potential energy savings in order to identify key areas where further resources and investments of the U.S. Department of Energy’s Office of Energy Efficiency and Renewable Energy (DOE EERE) would have the most impact on U.S. competiveness. After considering the current market, several potential near-term application areas were identified as having significant market and energy savings potential with respect to clean energy applications: (1) data centers (uninterruptible power supplies and server power supplies); (2) renewable energy generation (photovoltaic-solar and wind); (3) motor drives (industrial, commercial and residential); (4) rail traction; and, (5) hybrid and electric vehicles (traction and charging). After the initial explorative analyses, it became clear that, SiC, not GaN, would be the principal WBG power device material for the chosen markets in the near future. Therefore, while GaN is discussed when appropriate, this report focuses on SiC devices, other WBG applications (e.g., solid-state transformers, combined heat and power, medical, and wireless power), the GaN market, and GaN specific applications (e.g., LiDAR, 5G) will be explored at a later date. In addition to the market, supply and value chain analyses addressed in Section 1 of this report, a SWOT (Strength, Weakness, Opportunity, Threat) analysis and potential energy savings analysis was conducted for each application area to identify the major potential WBG application area(s) with a U.S. competitiveness opportunity in the future.

  7. Real Time Wide Area Radiation Surveillance System

    Science.gov (United States)

    Biafore, M.

    2012-04-01

    We present the REWARD project, financed within the FP7 programme, theme SEC-2011.1.5-1 (Development of detection capabilities of difficult to detect radioactive sources and nuclear materials - Capability Project). Within this project, we propose a novel mobile system for real time, wide area radiation surveillance. The system is based on the integration of new miniaturized solid-state radiation sensors: a CdZnTe detector for gamma radiation and a high efficiency neutron detector based on novel silicon technologies. The sensing unit will include a wireless communication interface to send the data remotely to a monitoring base station which also uses a GPS system to calculate the position of the tag. The system will also incorporate middleware and high level software to provide web-service interfaces for the exchange of information, and that will offer top level functionalities as management of users, mobile tags and environment data and alarms, database storage and management and a web-based graphical user interface. Effort will be spent to ensure that the software is modular and re-usable across as many architectural levels as possible. Finally, an expert system will continuously analyze the information from the radiation sensor and correlate it with historical data from the tag location in order to generate an alarm when an abnormal situation is detected. The system will be useful for many different scenarios, including such lost radioactive sources and radioactive contamination. It will be possible to deploy in emergency units and in general in any type of mobile or static equipment. The sensing units will be highly portable thanks to their low size and low energy consumption. The complete system will be scalable in terms of complexity and cost and will offer very high precision on both the measurement and the location of the radiation. The modularity and flexibility of the system will allow for a realistic introduction to the market. Authorities may start with a

  8. Wide Band and Wide Azimuth Beam Effect on High-resolution Synthetic Aperture Radar Radiometric Calibration

    Directory of Open Access Journals (Sweden)

    Hong Jun

    2015-06-01

    Full Text Available Passive corner reflectors and active transponders are often used as man-made reference targets in Synthetic Aperture Radar (SAR radiometric calibration, With the emergence of new radar systems and the increasing demand for greater accuracy, wide-band and wide-beam radars challenge the hypothesis that the Radar Cross Section (RCS of reference targets is constant. In this study, the FEKO electromagnetic simulation software is used to obtain the change curve of the target RCS as a function of frequency and aspect angle while incorporating high-resolution point-target SAR simulation, and quantitatively analyzing the effect of the modulation effect on SAR images. The simulation results suggest that the abovementioned factors affect the SAR calibration by more than 0.2 dB within a fractional bandwidth greater than 10% or azimuth beam width of more than 20°, which must be corrected in the data processing.

  9. World Wide Web voted most wonderful wonder by web-wide world

    CERN Multimedia

    2007-01-01

    The results are in, and the winner is...the World Wide Web! An online survey conducted by the CNN news group ranks the World Wide Web-invented at CERN--as the most wonderful of the seven modern wonders of the world. (See Bulletin No. 49/2006.) There is currently no speculation about whether they would have had the same results had they distributed the survey by post. The World Wide Web won with a whopping 50 per cent of the votes (3,665 votes). The runner up was CERN again, with 16 per cent of voters (1130 votes) casting the ballot in favour of the CERN particle accelerator. Stepping into place behind CERN and CERN is 'None of the Above' with 8 per cent of the votes (611 votes), followed by the development of Dubai (7%), the bionic arm (7%), China's Three Gorges Damn (5%), The Channel Tunnel (4%), and France's Millau viaduct (3%). Thanks to everyone from CERN who voted. You can view the results on http://edition.cnn.com/SPECIALS/2006/modern.wonders/

  10. Genome-Wide Mutagenesis in Borrelia burgdorferi.

    Science.gov (United States)

    Lin, Tao; Gao, Lihui

    2018-01-01

    population of mutants with different tags, after recovered from different tissues of infected mice and ticks, mutants from output pool and input pool are detected using high-throughput, semi-quantitative Luminex ® FLEXMAP™ or next-generation sequencing (Tn-seq) technologies. Thus far, we have created a high-density, sequence-defined transposon library of over 6600 STM mutants for the efficient genome-wide investigation of genes and gene products required for wild-type pathogenesis, host-pathogen interactions, in vitro growth, in vivo survival, physiology, morphology, chemotaxis, motility, structure, metabolism, gene regulation, plasmid maintenance and replication, etc. The insertion sites of 4480 transposon mutants have been determined. About 800 predicted protein-encoding genes in the genome were disrupted in the STM transposon library. The infectivity and some functions of 800 mutants in 500 genes have been determined. Analysis of these transposon mutants has yielded valuable information regarding the genes and gene products important in the pathogenesis and biology of B. burgdorferi and its tick vectors.

  11. SU-F-T-84: Measurement and Monte-Carlo Simulation of Electron Phase Spaces Using a Wide Angle Magnetic Electron Spectrometer

    Energy Technology Data Exchange (ETDEWEB)

    Englbrecht, F; Lindner, F; Bin, J; Wislsperger, A; Reiner, M; Kamp, F; Belka, C; Dedes, G; Schreiber, J; Parodi, K [LMU Munich, Munich, Bavaria (Germany)

    2016-06-15

    Purpose: To measure and simulate well-defined electron spectra using a linear accelerator and a permanent-magnetic wide-angle spectrometer to test the performance of a novel reconstruction algorithm for retrieval of unknown electron-sources, in view of application to diagnostics of laser-driven particle acceleration. Methods: Six electron energies (6, 9, 12, 15, 18 and 21 MeV, 40cm × 40cm field-size) delivered by a Siemens Oncor linear accelerator were recorded using a permanent-magnetic wide-angle electron spectrometer (150mT) with a one dimensional slit (0.2mm × 5cm). Two dimensional maps representing beam-energy and entrance-position along the slit were measured using different scintillating screens, read by an online CMOS detector of high resolution (0.048mm × 0.048mm pixels) and large field of view (5cm × 10cm). Measured energy-slit position maps were compared to forward FLUKA simulations of electron transport through the spectrometer, starting from IAEA phase-spaces of the accelerator. The latter ones were validated against measured depth-dose and lateral profiles in water. Agreement of forward simulation and measurement was quantified in terms of position and shape of the signal distribution on the detector. Results: Measured depth-dose distributions and lateral profiles in the water phantom showed good agreement with forward simulations of IAEA phase-spaces, thus supporting usage of this simulation source in the study. Measured energy-slit position maps and those obtained by forward Monte-Carlo simulations showed satisfactory agreement in shape and position. Conclusion: Well-defined electron beams of known energy and shape will provide an ideal scenario to study the performance of a novel reconstruction algorithm using measured and simulated signal. Future work will increase the stability and convergence of the reconstruction-algorithm for unknown electron sources, towards final application to the electrons which drive the interaction of TW-class laser

  12. Contracting Data Analysis: Assessment of Government-Wide Trends

    Science.gov (United States)

    2017-03-01

    CONTRACTING DATA ANALYSIS Assessment of Government -wide Trends Report to Congressional Addressees March 2017...Office Highlights of GAO-17-244SP, a report to congressional addressees March 2017 CONTRACTING DATA ANALYSIS Assessment of Government -wide...Trends What GAO Found GAO’s analysis of government -wide contracting data found that while defense obligations to buy products and services

  13. Wide and ultra-wide bandgap oxides: where paradigm-shift photovoltaics meets transparent power electronics

    Science.gov (United States)

    Pérez-Tomás, Amador; Chikoidze, Ekaterine; Jennings, Michael R.; Russell, Stephen A. O.; Teherani, Ferechteh H.; Bove, Philippe; Sandana, Eric V.; Rogers, David J.

    2018-03-01

    Oxides represent the largest family of wide bandgap (WBG) semiconductors and also offer a huge potential range of complementary magnetic and electronic properties, such as ferromagnetism, ferroelectricity, antiferroelectricity and high-temperature superconductivity. Here, we review our integration of WBG and ultra WBG semiconductor oxides into different solar cells architectures where they have the role of transparent conductive electrodes and/or barriers bringing unique functionalities into the structure such above bandgap voltages or switchable interfaces. We also give an overview of the state-of-the-art and perspectives for the emerging semiconductor β- Ga2O3, which is widely forecast to herald the next generation of power electronic converters because of the combination of an UWBG with the capacity to conduct electricity. This opens unprecedented possibilities for the monolithic integration in solar cells of both self-powered logic and power electronics functionalities. Therefore, WBG and UWBG oxides have enormous promise to become key enabling technologies for the zero emissions smart integration of the internet of things.

  14. Chlorophyll-a Concentration Retrieval in the Optically Complex Waters of the St. Lawrence Estuary and Gulf Using Principal Component Analysis

    Directory of Open Access Journals (Sweden)

    Julien Laliberté

    2018-02-01

    Full Text Available Empirical methods based on band ratios to infer chlorophyll-a concentration by satellite do not perform well over the optically complex waters of the St. Lawrence Estuary and Gulf. Using a dataset of 93 match-ups, we explore an alternative method relying on empirical orthogonal functions (EOF to develop an algorithm that relates the satellite-derived remote sensing reflectances to in situ chlorophyll-a concentration for the Sea-viewing Wide Field-of-view Sensor (SeaWiFS. Results show that an accuracy of 41% at retrieving chlorophyll-a concentration can be reached using the EOF method compared to 140% for the widely-used Ocean Chlorophyll 4 (OC4v4 empirical algorithm, 53% for the Garver-Siegel-Maritorena (GSM01 and 54% for the Generalized Inherent Optical Property (GIOP semi-analytical algorithms. This result is possible because the EOF approach is able to extract region-specific radiometric features from the satellite remote sensing reflectances that are related to absorption properties of optical components (water, coloured dissolved organic matter and chlorophyll-a using the visible SeaWiFS channels. The method could easily be used with other ocean-colour satellite sensors (e.g., MODIS, MERIS, VIIRS, OLCI to extend the time series for the St. Lawrence Estuary and Gulf waters.

  15. Application of a multilayer perceptron neural network to phytoplankton concentration using marine reflectance measures

    Science.gov (United States)

    Su, Feng-Chun; Ho, Chung-Ru; Kuo, Nan-Jung

    2005-01-01

    The multilayer perceptron (MLP) neural network have been widely used to fit non-linear transfer function and performed well. In this study, we use MLP to estimate chlorophyll-a concentrations from marine reflectance measures. The optical data were assembled from the Sea-viewing Wide Field-of-view Sensor (SeaWiFS) Bio-optical Algorithm Mini-workshop (SeaBAM). Most bio-optical algorithms use simple ratios of reflectance in blue and green bands or combinations of ratios as parameters for regression analysis. Regression analysis has limitations for nonlinear function. Neural network, however, have been shown better performance for nonlinear problems. The result showed that accuracy of chlorophyll-a concentration using MLP is much higher than that of regression method. Nevertheless, using all of the five bands as input can derive the best performance. The results showed that each band could carry some useful messages for ocean color remote sensing. Only using band ratio (OC2) or band switch (OC4) might lose some available information. By preprocessing reflectance data with the principle component analysis (PCA), MLP could derive much better accuracy than traditional methods. The result showed that the reflectance of all bands should not be ignored for deriving the chlorophyll-a concentration because each band carries different useful ocean color information.

  16. Time-Series Analysis of Remotely-Sensed SeaWiFS Chlorophyll in River-Influenced Coastal Regions

    Science.gov (United States)

    Acker, James G.; McMahon, Erin; Shen, Suhung; Hearty, Thomas; Casey, Nancy

    2009-01-01

    The availability of a nearly-continuous record of remotely-sensed chlorophyll a data (chl a) from the Sea-viewing Wide Field-of-view Sensor (SeaWiFS) mission, now longer than ten years, enables examination of time-series trends for multiple global locations. Innovative data analysis technology available on the World Wide Web facilitates such analyses. In coastal regions influenced by river outflows, chl a is not always indicative of actual trends in phytoplankton chlorophyll due to the interference of colored dissolved organic matter and suspended sediments; significant chl a timeseries trends for coastal regions influenced by river outflows may nonetheless be indicative of important alterations of the hydrologic and coastal environment. Chl a time-series analysis of nine marine regions influenced by river outflows demonstrates the simplicity and usefulness of this technique. The analyses indicate that coastal time-series are significantly influenced by unusual flood events. Major river systems in regions with relatively low human impact did not exhibit significant trends. Most river systems with demonstrated human impact exhibited significant negative trends, with the noteworthy exception of the Pearl River in China, which has a positive trend.

  17. The South Pole and the Ross Sea

    Science.gov (United States)

    2002-01-01

    This image shows a rare clear view of the South Pole (lower right) and the Ross Sea, Antarctica. The Sea-viewing Wide Field-of-view Sensor (SeaWiFS) acquired the scene on December 26, 2001. The geographic South Pole is located in the center of Antarctica, at an altitude of 2,900 meters (9,300 feet). It rests on a continent-wide ice sheet that is 2,870 m thick, with the underlying bedrock only 30 m (98 feet) above sea level. The ice underlying the South Pole is as much as 140,000 years old, and is currently accumulating at about 82 cm (32 inches) per year. Roughly 2,500 km (1,550 miles) away is the green water of the Ross Sea, which indicates the presence of large numbers of phytoplankton. This is a highly productive part of the world's oceans. Also note the ice gathered around McMurdo Sound, seen toward the lefthand shoreline of the Ross Sea, at the edge of the Ross Ice Shelf. According to National Science Foundation researchers, this ice is making it difficult for penguins to reach their food supply. Separating the continental Antarctic ice sheet from the Ross Sea are the Queen Maud Mountains and the Ross Ice Shelf. Image courtesy the SeaWiFS Project, NASA/Goddard Space Flight Center, and ORBIMAGE

  18. Review of wide band-gap semiconductors technology

    Directory of Open Access Journals (Sweden)

    Jin Haiwei

    2016-01-01

    Full Text Available Silicon carbide (SiC and gallium nitride (GaN are typical representative of the wide band-gap semiconductor material, which is also known as third-generation semiconductor materials. Compared with the conventional semiconductor silicon (Si or gallium arsenide (GaAs, wide band-gap semiconductor has the wide band gap, high saturated drift velocity, high critical breakdown field and other advantages; it is a highly desirable semiconductor material applied under the case of high-power, high-temperature, high-frequency, anti-radiation environment. These advantages of wide band-gap devices make them a hot spot of semiconductor technology research in various countries. This article describes the research agenda of United States and European in this area, focusing on the recent developments of the wide band-gap technology in the US and Europe, summed up the facing challenge of the wide band-gap technology.

  19. Fast neutron dosimeter with wide base silicon diode

    International Nuclear Information System (INIS)

    Ma Lu

    1986-01-01

    This paper briefly introduces a wide base silicon diode fast neutron dosimeter with wide measuring range and good energy response to fast neutron. It is suitable to be used to detect fast neutrons in the mixed field of γ-ray, thermal neutrons and fast neutrons

  20. Use of World Wide Web and NCSA Mcsaic at Langley

    Science.gov (United States)

    Nelson, Michael

    1994-01-01

    A brief history of the use of the World Wide Web at Langley Research Center is presented along with architecture of the Langley Web. Benefits derived from the Web and some Langley projects that have employed the World Wide Web are discussed.

  1. Basic support for cooperative work on the World Wide Web

    NARCIS (Netherlands)

    Bentley, R.; Appelt, W.; Busbach, U.; Hinrichs, E.; Kerr, D.; Sikkel, Nicolaas; Trevor, J.; Woetzel, G.

    The emergence and widespread adoption of the World Wide Web offers a great deal of potential in supporting cross-platform cooperative work within widely dispersed working groups. The Basic Support for Cooperative Work (BSCW) project at GMD is attempting to realize this potential through development

  2. Database Support for Workflow Management: The WIDE Project

    NARCIS (Netherlands)

    Grefen, P.W.P.J.; Pernici, B; Sánchez, G.; Unknown, [Unknown

    1999-01-01

    Database Support for Workflow Management: The WIDE Project presents the results of the ESPRIT WIDE project on advanced database support for workflow management. The book discusses the state of the art in combining database management and workflow management technology, especially in the areas of

  3. A Design of Wide Band and Wide Beam Cavity-Backed Slot Antenna Array with Slant Polarization

    Directory of Open Access Journals (Sweden)

    Huiying Qi

    2016-01-01

    Full Text Available Design of antenna array under the limitation of restricted size is a challenging problem. Cavity-backed slot antenna is widely used because of its advantages of small size, wide band, and wide beam. In this paper, a design of wide band and wide beam cavity-backed slot antenna array with the slant polarization is proposed. To obtain wide band and wide beam with limited size, the inverted microstrip-fed cavity-backed slot antenna (IMF-CBSA is adopted as the element of 1 × 4 antenna array. The slant polarized antennas and their feeding networks are adopted because of their simple structures. The performance of the proposed antenna array is verified by the simulations and experiments. The measured VSWR < 2 bandwidth is 55% at the center frequency 21.8 GHz, and the gain is larger than 12.2 dB. Experimental results demonstrate that the proposed design achieves wide band and beam with the size of 68 mm × 56 mm × 14.5 mm.

  4. mxCSM: A 100-slit, 6-Wavelength Wide-Field Coronal Spectropolarimeter for the Study of the Dynamics and the Magnetic Fields of the Solar Corona

    Energy Technology Data Exchange (ETDEWEB)

    Lin, Haosheng, E-mail: lin@ifa.hawaii.edu [Institute for Astronomy, University of Hawaii, Pukalani, HI (United States)

    2016-03-30

    Tremendous progress has been made in the field of observational coronal magnetometry in the first decade of the Twenty-First century. With the successful construction of the Coronal Multichannel Magnetometer (CoMP) instrument, observations of the linear polarization of the coronal emission lines (CELs), which carry information about the azimuthal direction of the coronal magnetic fields, are now routinely available. However, reliable and regular measurements of the circular polarization signals of the CELs remain illusive. The CEL circular polarization signals allow us to infer the magnetic field strength in the corona, and is critically important for our understanding of the solar corona. Current telescopes and instrument can only measure the coronal magnetic field strength over a small field of view. Furthermore, the observations require very long integration time that preclude the study of dynamic events even when only a small field of view is required. This paper describes a new instrument concept that employs large-scale multiplexing technology to enhance the efficiency of current coronal spectropolarimeter by more than two orders of magnitude. This will allow for the instrument to increase the integration time at each spatial location by the same factor, while also achieving a large field of view coverage. We will present the conceptual design of a 100-slit coronal spectropolarimeter that can observe six CELs simultaneously. Instruments based on this concept will allow us to study the evolution of the coronal magnetic field even with coronagraphs with modest aperture.

  5. mxCSM: A 100-slit, 6-wavelength wide-field coronal spectropolarimeter for the study of the dynamics and the magnetic fields of the solar corona

    Directory of Open Access Journals (Sweden)

    Haosheng eLin

    2016-03-01

    Full Text Available remendous progress has been made in the field of observational coronal magnetometry in the first decade of the 21st century. With the successful construction of the Coronal Multichannel Magnetometer (CoMP instrument, observations of the linear polarization of the coronal emission lines (CELs, which carry information about the azimuthal direction of the coronal magnetic fields, are now routinely available. However, reliable and regular measurements of the circular polarization signals of the CELs remain illusive. The CEL circular polarization signals allow us to infer the magnetic field strength in the corona, and is critically important {bf of} our understanding of the solar corona. Current telescopes and instrument can only measure the coronal magnetic field strength over a small field of view. Furthermore, the observations require very long integration time that preclude the study of dynamic events even when only a small field of view is required. This paper describes a new instrument concept that employees large-scale multiplexing technology to enhance the efficiency of current coronal spectropolarimeter by more than two orders of magnitude. This will allow for the instrument to increase of the integration time at each spatial location by the same factor, while also achieving a large field of view coverage. We will present the conceptual design of a 100-slit coronal spectropolarimeter that can observe six coronal emission lines simultaneously. Instruments based on this concept will allow us to study the evolution of the coronal magnetic field even with coronagraphs with modest aperture.

  6. A Wide Spectral Range Reflectance and Luminescence Imaging System

    Directory of Open Access Journals (Sweden)

    Tapani Hirvonen

    2013-10-01

    Full Text Available In this study, we introduce a wide spectral range (200–2500 nm imaging system with a 250 μm minimum spatial resolution, which can be freely modified for a wide range of resolutions and measurement geometries. The system has been tested for reflectance and luminescence measurements, but can also be customized for transmittance measurements. This study includes the performance results of the developed system, as well as examples of spectral images. Discussion of the system relates it to existing systems and methods. The wide range spectral imaging system that has been developed is however highly customizable and has great potential in many practical applications.

  7. Integrated wide-band low-background amplifiers

    International Nuclear Information System (INIS)

    Il'yushchenko, I.I.

    1980-01-01

    Ways of increasing stability and reproduction of characteristics of wide-band integral amplifiers that would to the least extent increase their background noises, are discussed. Considered are some certain flowsheets of integral wide-band amplifiers with low background noise of foreign production which differ from one another by construction of inlet cascades as well as by the applied feedback type. The principal flowsheets of the amplifiers and their main performances are presented. The analysis of the data obtained has revealed that microcircuits made of cascades with a common emitter and local combined feedback are most wide-band among all the considered microcircuits [ru

  8. Wide-band slow-wave systems simulation and applications

    CERN Document Server

    Staras, Stanislovas

    2012-01-01

    The field of electromagnetics has seen considerable advances in recent years, based on the wide applications of numerical methods for investigating electromagnetic fields, microwaves, and other devices. Wide-Band Slow-Wave Systems: Simulation and Applications presents new technical solutions and research results for the analysis, synthesis, and design of slow-wave structures for modern electronic devices with super-wide pass-bands. It makes available, for the first time in English, significant research from the past 20 years that was previously published only in Russian and Lithuanian. The aut

  9. Ultra-low-energy wide electron exposure unit

    International Nuclear Information System (INIS)

    Yonago, Akinobu; Oono, Yukihiko; Tokunaga, Kazutoshi; Kishimoto, Junichi; Wakamoto, Ikuo

    2001-01-01

    Heat and ultraviolet ray processes are used in surface dryness of paint, surface treatment of construction materials and surface sterilization of food containers. A process using a low-energy wide-area electron beam (EB) has been developed that features high speed and low drive cost. EB processing is not widespread in general industry, however, due to high equipment cost and difficult maintenance. We developed an ultra-low-energy wide-area electron beam exposure unit, the Mitsubishi Wide Electron Exposure Unit (MIWEL) to solve these problems. (author)

  10. A simple three dimensional wide-angle beam propagation method

    Science.gov (United States)

    Ma, Changbao; van Keuren, Edward

    2006-05-01

    The development of three dimensional (3-D) waveguide structures for chip scale planar lightwave circuits (PLCs) is hampered by the lack of effective 3-D wide-angle (WA) beam propagation methods (BPMs). We present a simple 3-D wide-angle beam propagation method (WA-BPM) using Hoekstra’s scheme along with a new 3-D wave equation splitting method. The applicability, accuracy and effectiveness of our method are demonstrated by applying it to simulations of wide-angle beam propagation and comparing them with analytical solutions.

  11. From silk to satellite: Half a century of ocean colour anomalies in the Northeast Atlantic

    KAUST Repository

    Raitsos, Dionysios E.; Pradhan, Yaswant; Lavender, Sam; Hoteit, Ibrahim; McQuatters-Gollop, Abigail L.; Reid, Philip Chris; Richardson, Anthony J.

    2014-01-01

    Changes in phytoplankton dynamics influence marine biogeochemical cycles, climate processes, and food webs, with substantial social and economic consequences. Large-scale estimation of phytoplankton biomass was possible via ocean colour measurements from two remote sensing satellites - the Coastal Zone Colour Scanner (CZCS, 1979-1986) and the Sea-viewing Wide Field-of-view Sensor (SeaWiFS, 1998-2010). Due to the large gap between the two satellite eras and differences in sensor characteristics, comparison of the absolute values retrieved from the two instruments remains challenging. Using a unique in situ ocean colour dataset that spans more than half a century, the two satellite-derived chlorophyll-a (Chl-a) eras are linked to assess concurrent changes in phytoplankton variability and bloom timing over the Northeast Atlantic Ocean and North Sea. Results from this unique re-analysis reflect a clear increasing pattern of Chl-a, a merging of the two seasonal phytoplankton blooms producing a longer growing season and higher seasonal biomass, since the mid-1980s. The broader climate plays a key role in Chl-a variability as the ocean colour anomalies parallel the oscillations of the Northern Hemisphere Temperature (NHT) since 1948. © 2013 John Wiley & Sons Ltd.

  12. An overview of the SeaWiFS project and strategies for producing a climate research quality global ocean bio-optical time series

    Science.gov (United States)

    McClain, Charles R.; Feldman, Gene C.; Hooker, Stanford B.

    2004-01-01

    The Sea-viewing Wide Field-of-view Sensor (SeaWiFS) Project Office was formally initiated at the NASA Goddard Space Flight Center in 1990. Seven years later, the sensor was launched by Orbital Sciences Corporation under a data-buy contract to provide 5 years of science quality data for global ocean biogeochemistry research. To date, the SeaWiFS program has greatly exceeded the mission goals established over a decade ago in terms of data quality, data accessibility and usability, ocean community infrastructure development, cost efficiency, and community service. The SeaWiFS Project Office and its collaborators in the scientific community have made substantial contributions in the areas of satellite calibration, product validation, near-real time data access, field data collection, protocol development, in situ instrumentation technology, operational data system development, and desktop level-0 to level-3 processing software. One important aspect of the SeaWiFS program is the high level of science community cooperation and participation. This article summarizes the key activities and approaches the SeaWiFS Project Office pursued to define, achieve, and maintain the mission objectives. These achievements have enabled the user community to publish a large and growing volume of research such as those contributed to this special volume of Deep-Sea Research. Finally, some examples of major geophysical events (oceanic, atmospheric, and terrestrial) captured by SeaWiFS are presented to demonstrate the versatility of the sensor.

  13. Thermocline Regulated Seasonal Evolution of Surface Chlorophyll in the Gulf of Aden

    KAUST Repository

    Yao, Fengchao

    2015-03-19

    The Gulf of Aden, although subject to seasonally reversing monsoonal winds, has been previously reported as an oligotrophic basin during summer, with elevated chlorophyll concentrations only occurring during winter due to convective mixing. However, the Sea-Viewing Wide Field-of-View Sensor (SeaWiFS) ocean color data reveal that the Gulf of Aden also exhibits a prominent summer chlorophyll bloom and sustains elevated chlorophyll concentrations throughout the fall, and is a biophysical province distinct from the adjacent Arabian Sea. Climatological hydrographic data suggest that the thermocline, hence the nutricline, in the entire gulf is markedly shoaled by the southwest monsoon during summer and fall. Under this condition, cyclonic eddies in the gulf can effectively pump deep nutrients to the surface layer and lead to the chlorophyll bloom in late summer, and, after the transition to the northeast monsoon in fall, coastal upwelling driven by the northeasterly winds produces a pronounced increase in surface chlorophyll concentrations along the Somali coast. © 2015 Yao, Hoteit.

  14. Quantification of Surface Suspended Sediments along a River Dominated Coast with NOAA AVHRR and SeaWiFS Measurements: Louisiana, USA

    Science.gov (United States)

    Myint, S. W.; Walker, N. D.

    2002-01-01

    The ability to quantify suspended sediment concentrations accurately over both time and space using satellite data has been a goal of many environmental researchers over the past few decades This study utilizes data acquired by the NOAA Advanced Very High Resolution Radiometer (AVHRR) and the Orbview-2 Sea-viewing wide field-of-view (SeaWiFS) ocean colour sensor, coupled with field measurements to develop statistical models for the estimation of near-surface suspended sediment and suspended solids "Ground truth" water samples were obtained via helicopter, small boat and automatic water sampler within a few hours of satellite overpasses The NOAA AVHRR atmospheric correction was modified for the high levels of turbidity along the Louisiana coast. Models were developed based on the field measurements and reflectance/radiance measurements in the visible and near infrared Channels of NOAA-14 and Orbview-2 SeaWiFS. The best models for predicting surface suspended sediment concentrations were obtained with a NOAA AVHRR Channel 1 (580-680nm) cubic model, Channel 2 (725-1100 nm) linear mod$ and SeaWiFs Channel 6 (660-68Onm) power modeL The suspended sediment models developed using SeaWiFS Channel 5 (545-565 nm) were inferior, a result that we attribute mainly to the atmospheric correction technique, the shallow depth of the water samples and absorption effects from non-sediment water constituents.

  15. Satellite Imagery and In-situ Data Overlay Approach for Fishery Zonation

    Directory of Open Access Journals (Sweden)

    Fardhi Adria

    2010-12-01

    Full Text Available Remote sensing technology can be used to better understand the earth’s characteristics. SeaWiFS (sea-viewing wide field-of-view sensor is one of remote sensors used to observe global ocean phenomena. Previous studies showed that the distribution of chlorophyll-a in the ocean indicates the presence of fish. However, only a few studies tried to directly relate the chlorophyll-a distribution obtained through interpretation of satellite imagery to in-situ data of fish distribution. This paper investigates the relation between chlorophyll-a distribution and fish-capturing points in Aceh Province sea waters using overlay image analysis. The results are then used to identify the potential fishing ground in Aceh. The profile of chlorophyll-a concentration is derived from SeaWIFS satellite imagery. Fish-capturing points data is obtained from the fisherman communities of Banda Aceh, starting from June to November 2008. The results showed that the chlorophyll-a profile derived from satellite imagery has a positive relationship to fish-capturing point data. The most potential fish-capturing zone in Aceh sea waters is identified at 5-8º north latitude (N and 96-99º east longitude (E.

  16. Comparison of Satellite-Derived Phytoplankton Size Classes Using In-Situ Measurements in the South China Sea

    Directory of Open Access Journals (Sweden)

    Shuibo Hu

    2018-03-01

    Full Text Available Ocean colour remote sensing is used as a tool to detect phytoplankton size classes (PSCs. In this study, the Medium Resolution Imaging Spectrometer (MERIS, Moderate Resolution Imaging Spectroradiometer (MODIS, and Sea-viewing Wide Field-of-view Sensor (SeaWiFS phytoplankton size classes (PSCs products were compared with in-situ High Performance Liquid Chromatography (HPLC data for the South China Sea (SCS, collected from August 2006 to September 2011. Four algorithms were evaluated to determine their ability to detect three phytoplankton size classes. Chlorophyll-a (Chl-a and absorption spectra of phytoplankton (aph(λ were also measured to help understand PSC’s algorithm performance. Results show that the three abundance-based approaches performed better than the inherent optical property (IOP-based approach in the SCS. The size detection of microplankton and picoplankton was generally better than that of nanoplankton. A three-component model was recommended to produce maps of surface PSCs in the SCS. For the IOP-based approach, satellite retrievals of inherent optical properties and the PSCs algorithm both have impacts on inversion accuracy. However, for abundance-based approaches, the selection of the PSCs algorithm seems to be more critical, owing to low uncertainty in satellite Chl-a input data

  17. Developing Benthic Class Specific, Chlorophyll-a Retrieving Algorithms for Optically-Shallow Water Using SeaWiFS

    Directory of Open Access Journals (Sweden)

    Tara Blakey

    2016-10-01

    Full Text Available This study evaluated the ability to improve Sea-Viewing Wide Field-of-View Sensor (SeaWiFS chl-a retrieval from optically shallow coastal waters by applying algorithms specific to the pixels’ benthic class. The form of the Ocean Color (OC algorithm was assumed for this study. The operational atmospheric correction producing Level 2 SeaWiFS data was retained since the focus of this study was on establishing the benefit from the alternative specification of the bio-optical algorithm. Benthic class was determined through satellite image-based classification methods. Accuracy of the chl-a algorithms evaluated was determined through comparison with coincident in situ measurements of chl-a. The regionally-tuned models that were allowed to vary by benthic class produced more accurate estimates of chl-a than the single, unified regionally-tuned model. Mean absolute percent difference was approximately 70% for the regionally-tuned, benthic class-specific algorithms. Evaluation of the residuals indicated the potential for further improvement to chl-a estimation through finer characterization of benthic environments. Atmospheric correction procedures specialized to coastal environments were recognized as areas for future improvement as these procedures would improve both classification and algorithm tuning.

  18. Retrieval of Optical Parameters From Seawifs Observations Over The Pomme Area (north-est Atlantic): Biogeochemical Applications

    Science.gov (United States)

    Loisel, H.; Nicolas, J.-M.; Merien, D.; Claustre, H.; Sciandra, A.; Becu, G.; Deschamps, P.-Y.

    Since the success of the first ocean color instrument, the Coastal Zone Color Sen- sor (CZCS), the interpretation of ocean color in terms of phytoplankton pigment (the chlorophyll, Chl) is now well recognized. The chlorophyll data, as detected from space, are now currently used to constraint oceanic biological models. New gener- ation of biological models now integrate explicitly 2 or more species of plankton, as well as dissolved organic and particulate matter, DOC and POC, respectively. The as- sessment of such information from the Sea-viewing Wide Field-of-view Sensor and inverse modeling will be discussed. In the frame of the POMME (Programme Océan Multidisciplinaire Méso-Echelle) project we will present the seasonal variability of the absorption, a, the backscattering, bb, and the scattering, b, coefficients as retrieved from SeaWiFS observations over the POMME area. These optical parameters will be compared with in situ measurements made during winter, spring and summer 2001, and biological information derived from these optical properties retrieved at different wavelengths will be presented.

  19. Spring Dust Storm Smothers Beijing

    Science.gov (United States)

    2002-01-01

    A few days earlier than usual, a large, dense plume of dust blew southward and eastward from the desert plains of Mongolia-quite smothering to the residents of Beijing. Citizens of northeastern China call this annual event the 'shachenbao,' or 'dust cloud tempest.' However, the tempest normally occurs during the spring time. The dust storm hit Beijing on Friday night, March 15, and began coating everything with a fine, pale brown layer of grit. The region is quite dry; a problem some believe has been exacerbated by decades of deforestation. According to Chinese government estimates, roughly 1 million tons of desert dust and sand blow into Beijing each year. This true-color image was made using two adjacent swaths (click to see the full image) of data from the Sea-viewing Wide Field-of-view Sensor (SeaWiFS), flying aboard the OrbView-2 satellite, on March 17, 2002. The massive dust storm (brownish pixels) can easily be distinguished from clouds (bright white pixels) as it blows across northern Japan and eastward toward the open Pacific Ocean. The black regions are gaps between SeaWiFS' viewing swaths and represent areas where no data were collected. Image courtesy the SeaWiFS Project, NASA/Goddard Space Flight Center, and ORBIMAGE

  20. Atmospheric correction of SeaWiFS ocean color imagery in the presence of absorbing aerosols off the Indian coast using a neuro-variational method

    Science.gov (United States)

    Brajard, J.; Moulin, C.; Thiria, S.

    2008-10-01

    This paper presents a comparison of the atmospheric correction accuracy between the standard sea-viewing wide field-of-view sensor (SeaWiFS) algorithm and the NeuroVaria algorithm for the ocean off the Indian coast in March 1999. NeuroVaria is a general method developed to retrieve aerosol optical properties and water-leaving reflectances for all types of aerosols, including absorbing ones. It has been applied to SeaWiFS images of March 1999, during an episode of transport of absorbing aerosols coming from pollutant sources in India. Water-leaving reflectances and aerosol optical thickness estimated by the two methods were extracted along a transect across the aerosol plume for three days. The comparison showed that NeuroVaria allows the retrieval of oceanic properties in the presence of absorbing aerosols with a better spatial and temporal stability than the standard SeaWiFS algorithm. NeuroVaria was then applied to the available SeaWiFS images over a two-week period. NeuroVaria algorithm retrieves ocean products for a larger number of pixels than the standard one and eliminates most of the discontinuities and artifacts associated with the standard algorithm in presence of absorbing aerosols.

  1. From silk to satellite: Half a century of ocean colour anomalies in the Northeast Atlantic

    KAUST Repository

    Raitsos, Dionysios E.

    2014-04-23

    Changes in phytoplankton dynamics influence marine biogeochemical cycles, climate processes, and food webs, with substantial social and economic consequences. Large-scale estimation of phytoplankton biomass was possible via ocean colour measurements from two remote sensing satellites - the Coastal Zone Colour Scanner (CZCS, 1979-1986) and the Sea-viewing Wide Field-of-view Sensor (SeaWiFS, 1998-2010). Due to the large gap between the two satellite eras and differences in sensor characteristics, comparison of the absolute values retrieved from the two instruments remains challenging. Using a unique in situ ocean colour dataset that spans more than half a century, the two satellite-derived chlorophyll-a (Chl-a) eras are linked to assess concurrent changes in phytoplankton variability and bloom timing over the Northeast Atlantic Ocean and North Sea. Results from this unique re-analysis reflect a clear increasing pattern of Chl-a, a merging of the two seasonal phytoplankton blooms producing a longer growing season and higher seasonal biomass, since the mid-1980s. The broader climate plays a key role in Chl-a variability as the ocean colour anomalies parallel the oscillations of the Northern Hemisphere Temperature (NHT) since 1948. © 2013 John Wiley & Sons Ltd.

  2. The moon as a radiometric reference source for on-orbit sensor stability calibration

    Science.gov (United States)

    Stone, T.C.

    2009-01-01

    The wealth of data generated by the world's Earth-observing satellites, now spanning decades, allows the construction of long-term climate records. A key consideration for detecting climate trends is precise quantification of temporal changes in sensor calibration on-orbit. For radiometer instruments in the solar reflectance wavelength range (near-UV to shortwave-IR), the Moon can be viewed as a solar diffuser with exceptional stability properties. A model for the lunar spectral irradiance that predicts the geometric variations in the Moon's brightness with ???1% precision has been developed at the U.S. Geological Survey in Flagstaff, AZ. Lunar model results corresponding to a series of Moon observations taken by an instrument can be used to stabilize sensor calibration with sub-percent per year precision, as demonstrated by the Sea-viewing Wide Field-of-view Sensor (SeaWiFS). The inherent stability of the Moon and the operational model to utilize the lunar irradiance quantity provide the Moon as a reference source for monitoring radiometric calibration in orbit. This represents an important capability for detecting terrestrial climate change from space-based radiometric measurements.

  3. Application of remote sensing in aquatic ecosystems

    Science.gov (United States)

    Yousef, Foad

    I utilized state the art remote sensing and GIS (Geographical Information System) techniques to study large scale biological, physical and ecological processes of coastal, nearshore, and offshore waters of Lake Michigan and Lake Superior. These processes ranged from chlorophyll alpha and primary production time series analysies in Lake Michigan to coastal stamp sand threats on Buffalo Reef in Lake Superior. I used SeaWiFS (Sea-viewing Wide Field-of-view Sensor) satellite imagery to trace various biological, chemical and optical water properties of Lake Michigan during the past decade and to investigate the collapse of early spring primary production. Using spatial analysis techniques, I was able to connect these changes to some important biological processes of the lake (quagga mussels filtration). In a separate study on Lake Superior, using LiDAR (Light Detection and Ranging) and aerial photos, we examined natural coastal erosion in Grand Traverse Bay, Michigan, and discussed a variety of geological features that influence general sediment accumulation patterns and interactions with migrating tailings from legacy mining. These sediments are moving southwesterly towards Buffalo Reef, creating a threat to the lake trout and lake whitefish breeding ground.

  4. Modified Light Use Efficiency Model for Assessment of Carbon Sequestration in Grasslands of Kazakhstan: Combining Ground Biomass Data and Remote-sensing

    Science.gov (United States)

    Propastin, Pavel A.; Kappas, Martin W.; Herrmann, Stefanie M.; Tucker, Compton J.

    2012-01-01

    A modified light use efficiency (LUE) model was tested in the grasslands of central Kazakhstan in terms of its ability to characterize spatial patterns and interannual dynamics of net primary production (NPP) at a regional scale. In this model, the LUE of the grassland biome (en) was simulated from ground-based NPP measurements, absorbed photosynthetically active radiation (APAR) and meteorological observations using a new empirical approach. Using coarse-resolution satellite data from the Sea-viewing Wide Field-of-view Sensor (SeaWiFS), monthly NPP was calculated from 1998 to 2008 over a large grassland region in Kazakhstan. The modelling results were verified against scaled up plot-level observations of grassland biomass and another available NPP data set derived from a field study in a similar grassland biome. The results indicated the reliability of productivity estimates produced by the model for regional monitoring of grassland NPP. The method for simulation of en suggested in this study can be used in grassland regions where no carbon flux measurements are accessible.

  5. Sea Surface Temperature and Ocean Color Variability in the South China Sea

    Science.gov (United States)

    Conaty, A. P.

    2001-12-01

    The South China Sea is a marginal sea in the Southeast Asian region whose surface circulation is driven by monsoons and whose surface currents have complex seasonal patterns. Its rich natural resources and strategic location have made its small islands areas of political dispute among the neighboring nations. This study aims to show the seasonal and interannual variability of sea surface temperature and ocean color in South China Sea. It makes use of NOAA's Advanced Very High Resolution Radiometer (AVHRR) satellite data sets on sea surface temperature for the period 1981-2000 and NASA's Nimbus-7 Coastal Zone Color Scanner (CZCS) and Sea-viewing Wide Field-of-view Sensor (SeaWiFS) satellite data sets on pigment concentration (ocean color) for the period 1981-1996 and 1997-2000, respectively. Transect lines were drawn along several potential hotspot areas to show the variability in sea surface temperature and pigment concentration through time. In-situ data on sea surface temperature along South China Sea were likewise plotted to see the variability with time. Higher seasonal variability in sea surface temperature was seen at higher latitudes. Interannual variability was within 1-3 Kelvin. In most areas, pigment concentration was higher during northern hemisphere winter and autumn, after the monsoon rains, with a maximum of 30 milligrams per cubic meter.

  6. Further Studies on the Physical and Biogeochemical Causes for Large Interannual Changes in the Patagonian Shelf Spring-Summer Phytoplankton Bloom Biomass

    Science.gov (United States)

    Signorini, Sergio R.; Garcia, Virginia M.T.; Piola, Alberto R.; Evangelista, Heitor; McClain, Charles R.; Garcia, Carlos A.E.; Mata, Mauricio M.

    2009-01-01

    A very strong and persistent phytoplankton bloom was observed by ocean color satellites during September - December 2003 along the northern Patagonian shelf. The 2003 bloom had the highest extent and chlorophyll a (Chl-a) concentrations of the entire Sea-viewing Wide Field-of-view Sensor (SeaWiFS) period (1997 to present). SeaWiFS-derived Chl-a exceeded 20 mg/cu m in November at the bloom center. The bloom was most extensive in December when it spanned more than 300 km across the shelf and nearly 900 km north-south (35degS to 43degS). The northward reach and the deep penetration on the shelf of the 2003 bloom were quite anomalous when compared with other years, which showed the bloom more confined to the Patagonian shelf break (PSB). The PSB bloom is a conspicuous austral spring-summer feature detected by ocean color satellites and its timing can be explained using the Sverdrup critical depth theory. Based on high-resolution numerical simulations, in situ and remote sensing data, we provide some suggestions for the probable mechanisms responsible for that large interannual change of biomass as seen by ocean color satellites. Potential sources of macro and micro (e.g., Fe) nutrients that sustain the high phytoplankton productivity of the Patagonian shelf waters are identified, and the most likely physical processes that maintain the nutrient balance in the region are discussed.

  7. SeaWiFS technical report series. Volume 32: Level-3 SeaWiFS data products. Spatial and temporal binning algorithms

    Science.gov (United States)

    Hooker, Stanford B. (Editor); Firestone, Elaine R. (Editor); Acker, James G. (Editor); Campbell, Janet W.; Blaisdell, John M.; Darzi, Michael

    1995-01-01

    The level-3 data products from the Sea-viewing Wide Field-of-view Sensor (SeaWiFS) are statistical data sets derived from level-2 data. Each data set will be based on a fixed global grid of equal-area bins that are approximately 9 x 9 sq km. Statistics available for each bin include the sum and sum of squares of the natural logarithm of derived level-2 geophysical variables where sums are accumulated over a binning period. Operationally, products with binning periods of 1 day, 8 days, 1 month, and 1 year will be produced and archived. From these accumulated values and for each bin, estimates of the mean, standard deviation, median, and mode may be derived for each geophysical variable. This report contains two major parts: the first (Section 2) is intended as a users' guide for level-3 SeaWiFS data products. It contains an overview of level-0 to level-3 data processing, a discussion of important statistical considerations when using level-3 data, and details of how to use the level-3 data. The second part (Section 3) presents a comparative statistical study of several binning algorithms based on CZCS and moored fluorometer data. The operational binning algorithms were selected based on the results of this study.

  8. How the wet side of NOAA (NMFS and NOS) is using JPSS data

    Science.gov (United States)

    Wilson, C.

    2016-12-01

    The VIIRS (Visible Infrared Imaging Radiometer Suite) instrument on the JPSS satellite, launched in 2011, is the most recent of a series of US ocean-color satellite measurements. With the launch of VIIRS we now have a nineteen-year continuous time-series of ocean-color measurements, starting with SeaWiFS (Sea-Viewing Wide Field-of-View Sensor), launched in 1997, and followed by MODIS (Moderate Resolution Imaging Spectroradiometer) on the Aqua satellite that was launched in 2002. What is significant about the VIIRS launch is that it represents a transition from ocean-color satellite data being generated from research missions launched by NASA to an operational data-stream that NOAA has responsibility for. In this presentation I will present a broad array of projects that will demonstrate how NOS (National Ocean Service) and NMFS (National Marine Fisheries Service) are using VIIRS data, both ocean-color and sea-surface temperature. Since fisheries and ecosystems studies typically require long time series, on the order of years to decades, the utility of the VIIRS data is that it has been intercalibrated with legacy data-streams to provide a climate data record. The majority of the projects highlighted were developed as part of the NOAA ocean satellite course that has been conducted annually since 2005.

  9. Seasonal and nonseasonal variability of satellite-derived chlorophyll and colored dissolved organic matter concentration in the California Current

    Science.gov (United States)

    Kahru, Mati; Mitchell, B. Greg

    2001-02-01

    Time series of surface chlorophyll a concentration (Chl) and colored dissolved organic matter (CDOM) derived from the Ocean Color and Temperature Sensor and Sea-Viewing Wide Field-of-View Sensor were evaluated for the California Current area using regional algorithms. Satellite data composited for 8-day periods provide the ability to describe large-scale changes in surface parameters. These changes are difficult to detect based on in situ observations alone that suffer from undersampling the large temporal and spatial variability, especially in Chl. We detected no significant bias in satellite Chl estimates compared with ship-based measurements. The variability in CDOM concentration was significantly smaller than that in Chl, both spatially and temporally. While being subject to large interannual and short-term variations, offshore waters (100-1000 km from the shore) have an annual cycle of Chl and CDOM with a maximum in winter-spring (December-March) and a minimum in late summer. For inshore waters the maximum is more likely in spring (April-May). We detect significant increase in both Chl and CDOM off central and southern California during the La Niña year of 1999. The trend of increasing Chl and CDOM from October 1996 to June 2000 is statistically significant in many areas.

  10. Temporal Variations in the Photosynthetic Biosphere

    Science.gov (United States)

    Behrenfeld, Michael; Randerson, James; McClain, Charles; Feldman, Gene; Los, Sietse; Tucker, Compton; Falkowski, Paul; Field, Christopher; Frouin, Robert; Esaias, Wayne; hide

    2000-01-01

    In this report, we describe results from the first three years of global Sea-Viewing Wide Field-of-view Sensor (SeaWiFS) ocean chlorophyll and land plant measurements. This time period covered the end of one of the largest El Nino events in the past century and a strong La Nina. During this transition, terrestrial plant photosynthesis exhibited only a small change, whereas a significant increase in oceanic photosynthesis was observed. Latitudinal distributions of ocean production indicated that this increase in photosynthesis during the La Nina was distributed in the equatorial belt as well as in high production areas. The analysis also illustrated the large 'missing bloom' in ocean phytoplankton in the southern ocean. While land photosynthesis remained fairly steady during the third year of SeaWiFS measurements, ocean phytoplankton production continued to increase, albeit at a lower rate than from 1997 to 1999. Our results represent the first quantification of interannual variability in global scale ocean productivity. Significant Findings: An increase in ocean production during the first three years of the SeaWiFS mission; a strong hemispheric difference in the latitudinal distribution of ocean photosynthesis.

  11. Comparison of SeaWiFS measurements of the Moon with the U.S. Geological Survey lunar model.

    Science.gov (United States)

    Barnes, Robert A; Eplee, Robert E; Patt, Frederick S; Kieffer, Hugh H; Stone, Thomas C; Meister, Gerhard; Butler, James J; McClain, Charles R

    2004-11-01

    The Sea-Viewing Wide-Field-of-View Sensor (SeaWiFS) has made monthly observations of the Moon since 1997. Using 66 monthly measurements, the SeaWiFS calibration team has developed a correction for the instrument's on-orbit response changes. Concurrently, a lunar irradiance model has been developed by the U.S. Geological Survey (USGS) from extensive Earth-based observations of the Moon. The lunar irradiances measured by SeaWiFS are compared with the USGS model. The comparison shows essentially identical response histories for SeaWiFS, with differences from the model of less than 0.05% per thousand days in the long-term trends. From the SeaWiFS experience we have learned that it is important to view the entire lunar image at a constant phase angle from measurement to measurement and to understand, as best as possible, the size of each lunar image. However, a constant phase angle is not required for using the USGS model. With a long-term satellite lunar data set it is possible to determine instrument changes at a quality level approximating that from the USGS lunar model. However, early in a mission, when the dependence on factors such as phase and libration cannot be adequately determined from satellite measurements alone, the USGS model is critical to an understanding of trends in instruments that use the Moon for calibration. This is the case for SeaWiFS.

  12. Environmental Variability in the Florida Keys: Impacts on Coral Reef Resilience and Health

    Science.gov (United States)

    Soto, I. M.; Muller-Karger, F. E.

    2005-12-01

    Environmental variability contributes to both mass mortality and resilience in tropical coral reef communities. We assess variations in sea surface temperature (SST) and ocean color in the Florida Keys using satellite imagery, and provide insight into how this variability is associated with locations of resilient coral communities (those unaffected by or able to recover from major events). The project tests the hypothesis that areas with historically low environmental variability promote lower levels of coral reef resilience. Time series of SST from the Advanced Very High Resolution Radiometer (AVHRR) sensors and ocean color derived quantities (e.g., turbidity and chlorophyll) from the Sea-viewing Wide Field of View Sensor (SeaWiFS) are being constructed over the entire Florida Keys region for a period of twelve and nine years, respectively. These data will be compared with historical coral cover data derived from Landsat imagery (1984-2002). Improved understanding of the causes of coral reef decline or resilience will help protect and manage these natural treasures.

  13. Whiting in Lake Michigan

    Science.gov (United States)

    2002-01-01

    Satellites provide a view from space of changes on the Earth's surface. This series of images from the Sea-viewing Wide Field-of-view Sensor (SeaWiFS) aboard the Orbview-2 satellite shows the dramatic change in the color of Lake Michigan during the summer. The bright color that appears in late summer is probably caused by calcium carbonate-chalk-in the water. Lake Michigan always has a lot of calcium carbonate in it because the floor of the lake is limestone. During most of the year the calcium carbonate remains dissolved in the cold water, but at the end of summer the lake warms up, lowering the solubility of calcium carbonate. As a result, the calcium carbonate precipitates out of the water, forming clouds of very small solid particles that appear as bright swirls from above. The phenomenon is appropriately called a whiting event. A similar event occured in 1999, but appears to have started later and subsided earlier. It is also possible that a bloom of the algae Microcystis is responsible for the color change, but unlikely because of Lake Michigan's depth and size. Microcystis blooms have occured in other lakes in the region, however. On the shore of the lake it is possible to see the cities of Chicago, Illinois, and Milwaukee, Wisconsin. Both appear as clusters of gray-brown pixels. Image courtesy the SeaWiFS Project, NASA/Goddard Space Flight Center, and ORBIMAGE

  14. Global Ocean Phytoplankton

    Science.gov (United States)

    Franz, B. A.; Behrenfeld, M. J.; Siegel, D. A.; Werdell, P. J.

    2014-01-01

    Marine phytoplankton are responsible for roughly half the net primary production (NPP) on Earth, fixing atmospheric CO2 into food that fuels global ocean ecosystems and drives the ocean's biogeochemical cycles. Phytoplankton growth is highly sensitive to variations in ocean physical properties, such as upper ocean stratification and light availability within this mixed layer. Satellite ocean color sensors, such as the Sea-viewing Wide Field-of-view Sensor (SeaWiFS; McClain 2009) and Moderate Resolution Imaging Spectroradiometer (MODIS; Esaias 1998), provide observations of sufficient frequency and geographic coverage to globally monitor physically-driven changes in phytoplankton distributions. In practice, ocean color sensors retrieve the spectral distribution of visible solar radiation reflected upward from beneath the ocean surface, which can then be related to changes in the photosynthetic phytoplankton pigment, chlorophyll- a (Chla; measured in mg m-3). Here, global Chla data for 2013 are evaluated within the context of the 16-year continuous record provided through the combined observations of SeaWiFS (1997-2010) and MODIS on Aqua (MODISA; 2002-present). Ocean color measurements from the recently launched Visible and Infrared Imaging Radiometer Suite (VIIRS; 2011-present) are also considered, but results suggest that the temporal calibration of the VIIRS sensor is not yet sufficiently stable for quantitative global change studies. All MODISA (version 2013.1), SeaWiFS (version 2010.0), and VIIRS (version 2013.1) data presented here were produced by NASA using consistent Chla algorithms.

  15. Soil Compressibility Models for a Wide Stress Range

    KAUST Repository

    Chong, Song-Hun; Santamarina, Carlos

    2016-01-01

    Soil compressibility models with physically correct asymptotic void ratios are required to analyze situations that involve a wide stress range. Previously suggested models and other functions are adapted to satisfy asymptotic void ratios at low

  16. A micro-controller based wide range survey meter

    International Nuclear Information System (INIS)

    Bhingare, R.R.; Bajaj, K.C.; Kannan, S.

    2004-01-01

    Wide range survey meters (1μSv/h -10 Sv/h) with the detector(s) mounted at the end of a two-to-four meter-long extendable tube are widely used for radiation protection survey of difficult to reach locations and high dose rate areas, The commercially available survey meters of this type use two GM counters to cover a wide range of dose rate measurement. A new micro-controller based wide range survey meter using two Si diode detectors has been developed. The use of solid state detectors in the survey meter has a number of advantages like low power consumption, lighter battery powered detector probe, elimination of high voltage for the operation of the detectors, etc. The design uses infrared communication between the probe and the readout unit through a light-weight collapsible extension tube for high reliability. The design details and features are discussed in detail. (author)

  17. Detection of plane, poorly oriented wide flaws using focused transducers

    International Nuclear Information System (INIS)

    Vadder, D. de; Azou, P.; Bastien, P.; Saglio, R.

    1976-01-01

    The detection of plane, poorly oriented, wide flaws by ultrasonic non destructive testing is distinctly improved when using focused transducers. An increased echo can be obtained crossing the defect limit [fr

  18. Informal science education: lifelong, life-wide, life-deep.

    Science.gov (United States)

    Sacco, Kalie; Falk, John H; Bell, James

    2014-11-01

    Informal Science Education: Lifelong, Life-Wide, Life-Deep Informal science education cultivates diverse opportunities for lifelong learning outside of formal K-16 classroom settings, from museums to online media, often with the help of practicing scientists.

  19. Seattle wide-area information for travelers (SWIFT) : architecture study

    Science.gov (United States)

    1998-10-19

    The SWIFT (Seattle Wide-area Information For Travelers) Field Operational Test was intended to evaluate the performance of a large-scale urban Advanced Traveler Information System (ATIS) deployment in the Seattle area. The unique features of the SWIF...

  20. Distributing Congestion Management System Information Using the World Wide Web

    Science.gov (United States)

    1997-01-01

    The Internet is a unique medium for the distribution of information, and it provides a tremendous opportunity to take advantage of peoples innate interest in transportation issues as they relate to their own lives. In particular, the World Wide Web (...

  1. Panchromatic cooperative hyperspectral adaptive wide band deletion repair method

    Science.gov (United States)

    Jiang, Bitao; Shi, Chunyu

    2018-02-01

    In the hyperspectral data, the phenomenon of stripe deletion often occurs, which seriously affects the efficiency and accuracy of data analysis and application. Narrow band deletion can be directly repaired by interpolation, and this method is not ideal for wide band deletion repair. In this paper, an adaptive spectral wide band missing restoration method based on panchromatic information is proposed, and the effectiveness of the algorithm is verified by experiments.

  2. Genome-wide association study of multiplex schizophrenia pedigrees

    DEFF Research Database (Denmark)

    Levinson, Douglas F; Shi, Jianxin; Wang, Kai

    2012-01-01

    The authors used a genome-wide association study (GWAS) of multiply affected families to investigate the association of schizophrenia to common single-nucleotide polymorphisms (SNPs) and rare copy number variants (CNVs).......The authors used a genome-wide association study (GWAS) of multiply affected families to investigate the association of schizophrenia to common single-nucleotide polymorphisms (SNPs) and rare copy number variants (CNVs)....

  3. Security Analysis of a Software Defined Wide Area Network Solution

    OpenAIRE

    Rajendran, Ashok

    2016-01-01

    Enterprise wide area network (WAN) is a private network that connects the computers and other devices across an organisation's branch locations and the data centers. It forms the backbone of enterprise communication. Currently, multiprotocol label switching (MPLS) is commonly used to provide this service. As a recent alternative to MPLS, software-dened wide area networking (SD-WAN) solutions are being introduced as an IP based cloud-networking service for enterprises. SD-WAN virtualizes the n...

  4. U.S. Geological Survey World Wide Web Information

    Science.gov (United States)

    ,

    2003-01-01

    The U.S. Geological Survey (USGS) invites you to explore an earth science virtual library of digital information, publications, and data. The USGS World Wide Web sites offer an array of information that reflects scientific research and monitoring programs conducted in the areas of natural hazards, environmental resources, and cartography. This list provides gateways to access a cross section of the digital information on the USGS World Wide Web sites.

  5. Genome-wide association study of clinical dimensions of schizophrenia

    DEFF Research Database (Denmark)

    Fanous, Ayman H; Zhou, Baiyu; Aggen, Steven H

    2012-01-01

    Multiple sources of evidence suggest that genetic factors influence variation in clinical features of schizophrenia. The authors present the first genome-wide association study (GWAS) of dimensional symptom scores among individuals with schizophrenia.......Multiple sources of evidence suggest that genetic factors influence variation in clinical features of schizophrenia. The authors present the first genome-wide association study (GWAS) of dimensional symptom scores among individuals with schizophrenia....

  6. Wide color gamut display with white and emerald backlighting.

    Science.gov (United States)

    Duan, Lvyin; Lei, Zhichun

    2018-02-20

    This paper proposes a wide color gamut approach that uses white and emerald lighting units as the backlight of the liquid crystal display. The white and emerald backlights are controlled by the image to be displayed. The mixing ratio of the white and the emerald lighting is analyzed so that the maximal color gamut coverage ratio can be achieved. Experimental results prove the effectiveness of the wide color gamut approach using white and emerald backlights.

  7. WorldWideScience.org: Bringing Light to Grey

    OpenAIRE

    Hitson, Brian A. (OSTI-DOE); Johnson, Lorrie A. (OSTI-DOE); GreyNet, Grey Literature Network Service

    2008-01-01

    WorldWideScience.org and its governance structure, the WorldWideScience Alliance, are putting a brighter spotlight on grey literature. Through this new tool, grey literature is getting broader exposure to audiences all over the world. Improved access to and sharing of research information is the key to accelerating progress and breakthroughs in any field, especially science. Includes: Conference preprint, Powerpoint presentation, Abstract and Biographical notes, Pratt student commentary ...

  8. A Genome-Wide Breast Cancer Scan in African Americans

    Science.gov (United States)

    2010-06-01

    SNPs from the African American breast cancer scan to COGs , a European collaborative study which is has designed a SNP array with that will be genotyped...Award Number: W81XWH-08-1-0383 TITLE: A Genome-wide Breast Cancer Scan in African Americans PRINCIPAL INVESTIGATOR: Christopher A...SUBTITLE A Genome-wide Breast Cancer Scan in African Americans 5a. CONTRACT NUMBER 5b. GRANT NUMBER W81XWH-08-1-0383 5c. PROGRAM

  9. GWAMA: software for genome-wide association meta-analysis

    Directory of Open Access Journals (Sweden)

    Mägi Reedik

    2010-05-01

    Full Text Available Abstract Background Despite the recent success of genome-wide association studies in identifying novel loci contributing effects to complex human traits, such as type 2 diabetes and obesity, much of the genetic component of variation in these phenotypes remains unexplained. One way to improving power to detect further novel loci is through meta-analysis of studies from the same population, increasing the sample size over any individual study. Although statistical software analysis packages incorporate routines for meta-analysis, they are ill equipped to meet the challenges of the scale and complexity of data generated in genome-wide association studies. Results We have developed flexible, open-source software for the meta-analysis of genome-wide association studies. The software incorporates a variety of error trapping facilities, and provides a range of meta-analysis summary statistics. The software is distributed with scripts that allow simple formatting of files containing the results of each association study and generate graphical summaries of genome-wide meta-analysis results. Conclusions The GWAMA (Genome-Wide Association Meta-Analysis software has been developed to perform meta-analysis of summary statistics generated from genome-wide association studies of dichotomous phenotypes or quantitative traits. Software with source files, documentation and example data files are freely available online at http://www.well.ox.ac.uk/GWAMA.

  10. High-Temperature Electronics: A Role for Wide Bandgap Semiconductors?

    Science.gov (United States)

    Neudeck, Philip G.; Okojie, Robert S.; Chen, Liang-Yu

    2002-01-01

    It is increasingly recognized that semiconductor based electronics that can function at ambient temperatures higher than 150 C without external cooling could greatly benefit a variety of important applications, especially-in the automotive, aerospace, and energy production industries. The fact that wide bandgap semiconductors are capable of electronic functionality at much higher temperatures than silicon has partially fueled their development, particularly in the case of SiC. It appears unlikely that wide bandgap semiconductor devices will find much use in low-power transistor applications until the ambient temperature exceeds approximately 300 C, as commercially available silicon and silicon-on-insulator technologies are already satisfying requirements for digital and analog very large scale integrated circuits in this temperature range. However, practical operation of silicon power devices at ambient temperatures above 200 C appears problematic, as self-heating at higher power levels results in high internal junction temperatures and leakages. Thus, most electronic subsystems that simultaneously require high-temperature and high-power operation will necessarily be realized using wide bandgap devices, once the technology for realizing these devices become sufficiently developed that they become widely available. Technological challenges impeding the realization of beneficial wide bandgap high ambient temperature electronics, including material growth, contacts, and packaging, are briefly discussed.

  11. Ultra-wide-field imaging in diabetic retinopathy.

    Science.gov (United States)

    Ghasemi Falavarjani, Khalil; Tsui, Irena; Sadda, Srinivas R

    2017-10-01

    Since 1991, 7-field images captured with 30-50 degree cameras in the Early Treatment Diabetic Retinopathy Study were the gold standard for fundus imaging to study diabetic retinopathy. Ultra-wide-field images cover significantly more area (up to 82%) of the fundus and with ocular steering can in many cases image 100% of the fundus ("panretinal"). Recent advances in image analysis of ultra-wide-field imaging allow for precise measurements of the peripheral retinal lesions. There is a growing consensus in the literature that ultra-wide-field imaging improves detection of peripheral lesions in diabetic retinopathy and leads to more accurate classification of the disease. There is discordance among studies, however, on the correlation between peripheral diabetic lesions and diabetic macular edema and optimal management strategies to treat diabetic retinopathy. Copyright © 2017 Elsevier Ltd. All rights reserved.

  12. Chapter 10: Mining genome-wide genetic markers.

    Directory of Open Access Journals (Sweden)

    Xiang Zhang

    Full Text Available Genome-wide association study (GWAS aims to discover genetic factors underlying phenotypic traits. The large number of genetic factors poses both computational and statistical challenges. Various computational approaches have been developed for large scale GWAS. In this chapter, we will discuss several widely used computational approaches in GWAS. The following topics will be covered: (1 An introduction to the background of GWAS. (2 The existing computational approaches that are widely used in GWAS. This will cover single-locus, epistasis detection, and machine learning methods that have been recently developed in biology, statistic, and computer science communities. This part will be the main focus of this chapter. (3 The limitations of current approaches and future directions.

  13. Rethinking economy-wide rebound measures: An unbiased proposal

    International Nuclear Information System (INIS)

    Guerra, Ana-Isabel; Sancho, Ferran

    2010-01-01

    In spite of having been first introduced in the last half of the ninetieth century, the debate about the possible rebound effects from energy efficiency improvements is still an open question in the economic literature. This paper contributes to the existing research on this issue proposing an unbiased measure for economy-wide rebound effects. The novelty of this economy-wide rebound measure stems from the fact that not only actual energy savings but also potential energy savings are quantified under general equilibrium conditions. Our findings indicate that the use of engineering savings instead of general equilibrium potential savings downward biases economy-wide rebound effects and upward-biases backfire effects. The discrepancies between the traditional indicator and our proposed measure are analysed in the context of the Spanish economy.

  14. Estimating System-wide Impacts of Smart Grid Demonstrations

    Energy Technology Data Exchange (ETDEWEB)

    Schneider, Kevin P.; Lightner, Eric M.; Fuller, Jason C.

    2015-03-01

    Quantifying the impact of a new technology on a single specific distribution feeder is relatively easy, but it does not provide insight into the complexities and variations of a system-wide deployment. It is the inability to extrapolate system-wide impacts that hinders the deployment of many promising new technologies. This paper presents a method of extrapolating technology impacts, either simulated or from a field demonstration, from a limited number of distribution feeders to a system-wide impact. The size of the system can vary from the service territory of a single utility, to a region, or to an entire country. The paper will include an example analysis using the United States Department of Energy (DOE) funded Smart Grid Investment Grant (SGIG) projects, extrapolating their benefits to a national level.

  15. Architecture and Fault Identification of Wide-area Protection System

    Directory of Open Access Journals (Sweden)

    Yuxue Wang

    2012-09-01

    Full Text Available Wide-area protection system (WAPS is widely studied for the purpose of improvng the performance of conventional backup protection. In this paper, the system architecture of WAPS is proposed and its key technologies are discussed in view of engineering projects. So a mixed structurecentralized-distributed structure which is more suitable for WAPS in limited power grid region, is obtained based on the advantages of the centralized structure and distributed structure. Furthermore, regional distance protection algorithm was taken as an example to illustrate the functions of the constituent units. Faulted components can be detected based on multi-source imformation fuse in the algorithm. And the algorithm cannot only improve the selectivity, the rapidity, and the reliability of relaying protection but also has high fault tolerant capability. A simulation of 220 kV grid systems in Easter Hubei province shows the effectiveness of the wide-area protection system presented by this paper.

  16. A novel statistic for genome-wide interaction analysis.

    Directory of Open Access Journals (Sweden)

    Xuesen Wu

    2010-09-01

    Full Text Available Although great progress in genome-wide association studies (GWAS has been made, the significant SNP associations identified by GWAS account for only a few percent of the genetic variance, leading many to question where and how we can find the missing heritability. There is increasing interest in genome-wide interaction analysis as a possible source of finding heritability unexplained by current GWAS. However, the existing statistics for testing interaction have low power for genome-wide interaction analysis. To meet challenges raised by genome-wide interactional analysis, we have developed a novel statistic for testing interaction between two loci (either linked or unlinked. The null distribution and the type I error rates of the new statistic for testing interaction are validated using simulations. Extensive power studies show that the developed statistic has much higher power to detect interaction than classical logistic regression. The results identified 44 and 211 pairs of SNPs showing significant evidence of interactions with FDR<0.001 and 0.001wide interaction analysis is a valuable tool for finding remaining missing heritability unexplained by the current GWAS, and the developed novel statistic is able to search significant interaction between SNPs across the genome. Real data analysis showed that the results of genome-wide interaction analysis can be replicated in two independent studies.

  17. Interoperation of World-Wide Production e-Science Infrastructures

    CERN Document Server

    Riedel, M; Soddemann, T; Field, L; Navarro, JP; Casey, J; Litmaath, M; Baud, J; Koblitz, B; Catlett, C; Skow, D; Wang, S; Saeki, Y; Sato, H; Matsuoka, S; Geddes, N

    Many production Grid and e-Science infrastructures have begun to offer services to end-users during the past several years with an increasing number of scientific applications that require access to a wide variety of resources and services in multiple Grids. Therefore, the Grid Interoperation Now—Community Group of the Open Grid Forum—organizes and manages interoperation efforts among those production Grid infrastructures to reach the goal of a world-wide Grid vision on a technical level in the near future. This contribution highlights fundamental approaches of the group and discusses open standards in the context of production e-Science infrastructures.

  18. Adiponectin Concentrations: A Genome-wide Association Study

    OpenAIRE

    Jee, Sun Ha; Sull, Jae Woong; Lee, Jong-Eun; Shin, Chol; Park, Jongkeun; Kimm, Heejin; Cho, Eun-Young; Shin, Eun-Soon; Yun, Ji Eun; Park, Ji Wan; Kim, Sang Yeun; Lee, Sun Ju; Jee, Eun Jung; Baik, Inkyung; Kao, Linda

    2010-01-01

    Adiponectin is associated with obesity and insulin resistance. To date, there has been no genome-wide association study (GWAS) of adiponectin levels in Asians. Here we present a GWAS of a cohort of Korean volunteers. A total of 4,001 subjects were genotyped by using a genome-wide marker panel in a two-stage design (979 subjects initially and 3,022 in a second stage). Another 2,304 subjects were used for follow-up replication studies with selected markers. In the discovery phase, the top SNP a...

  19. Playing with the internet through world wide web

    International Nuclear Information System (INIS)

    Kim, Seon Tae; Jang, Jin Seok

    1995-07-01

    This book describes how to use the internet with world wide web. It is divided into six chapters, which are Let's go to the internet ocean, the internet in information superhighway are, connecting the world with a telephone wire such as link with the internet cable and telephone modem, internet service providers, text mode connection, Domain and IP address, the principle and use of world wide web ; business, music, fashion, movie and photo, internet news and e-mail, making internet map with web language, and from installation to application of base program such as TCP/IP, SLIP/PPP 3270 Emulator, Finger and NCSA Mosaic.

  20. Simultaneous wall-shear-stress and wide-field PIV measurements in a turbulent boundary layer

    Science.gov (United States)

    Gomit, Guillaume; Fourrie, Gregoire; de Kat, Roeland; Ganapathisubramani, Bharathram

    2015-11-01

    Simultaneous particle image velocimetry (PIV) and hot-film shear stress sensor measurements were performed to study the large-scale structures associated with shear stress events in a flat plate turbulent boundary layer at a high Reynolds number (Reτ ~ 4000). The PIV measurement was performed in a streamwise-wall normal plane using an array of six high resolution cameras (4 ×16MP and 2 ×29MP). The resulting field of view covers 8 δ (where δ is the boundary layer thickness) in the streamwise direction and captures the entire boundary layer in the wall-normal direction. The spatial resolution of the measurement is approximately is approximately 70 wall units (1.8 mm) and sampled each 35 wall units (0.9 mm). In association with the PIV setup, a spanwise array of 10 skin-friction sensors (spanning one δ) was used to capture the footprint of the large-scale structures. This combination of measurements allowed the analysis of the three-dimensional conditional structures in the boundary layer. Particularly, from conditional averages, the 3D organisation of the wall normal and streamwise velocity components (u and v) and the Reynolds shear stress (-u'v') related to a low and high shear stress events can be extracted. European Research Council Grant No-277472-WBT.

  1. Scalable gamma-ray camera for wide-area search based on silicon photomultipliers array

    Science.gov (United States)

    Jeong, Manhee; Van, Benjamin; Wells, Byron T.; D'Aries, Lawrence J.; Hammig, Mark D.

    2018-03-01

    Portable coded-aperture imaging systems based on scintillators and semiconductors have found use in a variety of radiological applications. For stand-off detection of weakly emitting materials, large volume detectors can facilitate the rapid localization of emitting materials. We describe a scalable coded-aperture imaging system based on 5.02 × 5.02 cm2 CsI(Tl) scintillator modules, each partitioned into 4 × 4 × 20 mm3 pixels that are optically coupled to 12 × 12 pixel silicon photo-multiplier (SiPM) arrays. The 144 pixels per module are read-out with a resistor-based charge-division circuit that reduces the readout outputs from 144 to four signals per module, from which the interaction position and total deposited energy can be extracted. All 144 CsI(Tl) pixels are readily distinguishable with an average energy resolution, at 662 keV, of 13.7% FWHM, a peak-to-valley ratio of 8.2, and a peak-to-Compton ratio of 2.9. The detector module is composed of a SiPM array coupled with a 2 cm thick scintillator and modified uniformly redundant array mask. For the image reconstruction, cross correlation and maximum likelihood expectation maximization methods are used. The system shows a field of view of 45° and an angular resolution of 4.7° FWHM.

  2. From Genome-Wide Association Study to Phenome-Wide Association Study: New Paradigms in Obesity Research.

    Science.gov (United States)

    Zhang, Y-P; Zhang, Y-Y; Duan, D D

    2016-01-01

    Obesity is a condition in which excess body fat has accumulated over an extent that increases the risk of many chronic diseases. The current clinical classification of obesity is based on measurement of body mass index (BMI), waist-hip ratio, and body fat percentage. However, these measurements do not account for the wide individual variations in fat distribution, degree of fatness or health risks, and genetic variants identified in the genome-wide association studies (GWAS). In this review, we will address this important issue with the introduction of phenome, phenomics, and phenome-wide association study (PheWAS). We will discuss the new paradigm shift from GWAS to PheWAS in obesity research. In the era of precision medicine, phenomics and PheWAS provide the required approaches to better definition and classification of obesity according to the association of obese phenome with their unique molecular makeup, lifestyle, and environmental impact. Copyright © 2016 Elsevier Inc. All rights reserved.

  3. Non-uniform sampling and wide range angular spectrum method

    International Nuclear Information System (INIS)

    Kim, Yong-Hae; Byun, Chun-Won; Oh, Himchan; Lee, JaeWon; Pi, Jae-Eun; Heon Kim, Gi; Lee, Myung-Lae; Ryu, Hojun; Chu, Hye-Yong; Hwang, Chi-Sun

    2014-01-01

    A novel method is proposed for simulating free space field propagation from a source plane to a destination plane that is applicable for both small and large propagation distances. The angular spectrum method (ASM) was widely used for simulating near field propagation, but it caused a numerical error when the propagation distance was large because of aliasing due to under sampling. Band limited ASM satisfied the Nyquist condition on sampling by limiting a bandwidth of a propagation field to avoid an aliasing error so that it could extend the applicable propagation distance of the ASM. However, the band limited ASM also made an error due to the decrease of an effective sampling number in a Fourier space when the propagation distance was large. In the proposed wide range ASM, we use a non-uniform sampling in a Fourier space to keep a constant effective sampling number even though the propagation distance is large. As a result, the wide range ASM can produce simulation results with high accuracy for both far and near field propagation. For non-paraxial wave propagation, we applied the wide range ASM to a shifted destination plane as well. (paper)

  4. Economy-wide Impact of Investment in Road Infrastructure in ...

    African Journals Online (AJOL)

    In this study an attempt has been made to examine economy wide impact of investment in road infrastructure using a recursive dynamic CGE model. The study used an updated version of the 2005/06 EDRI Social Accounting Matrix. Simulations with the CGE model confirm that with the increasing availability of road ...

  5. Note: A wide temperature range MOKE system with annealing capability.

    Science.gov (United States)

    Chahil, Narpinder Singh; Mankey, G J

    2017-07-01

    A novel sample stage integrated with a longitudinal MOKE system has been developed for wide temperature range measurements and annealing capabilities in the temperature range 65 K temperatures without adversely affecting the cryostat and minimizes thermal drift in position. In this system the hysteresis loops of magnetic samples can be measured simultaneously while annealing the sample in a magnetic field.

  6. WorldWideScience.org: the global science gateway.

    Science.gov (United States)

    Fitzpatrick, Roberta Bronson

    2009-10-01

    WorldWideScience.org is a Web-based global gateway connecting users to both national and international scientific databases and portals. This column will provide background information on the resource as well as introduce basic searching practices for users.

  7. Sources of Militaria on the World Wide Web | Walker | Scientia ...

    African Journals Online (AJOL)

    Having an interest in military-type topics is one thing, finding information on the web to quench your thirst for knowledge is another. The World Wide Web (WWW) is a universal electronic library that contains millions of web pages. As well as being fun, it is an addictive tool on which to search for information. To prevent hours ...

  8. Reactor Engineering Division Material for World Wide Web Pages

    International Nuclear Information System (INIS)

    1996-01-01

    This document presents the home page of the Reactor Engineering Division of Argonne National Laboratory. This WWW site describes the activities of the Division, an introduction to its wide variety of programs and samples of the results of research by people in the division

  9. a potential source of spurious associations in genome-wide ...

    Indian Academy of Sciences (India)

    2010-04-01

    Apr 1, 2010 ... Genome-wide association studies (GWAS) examine the entire human genome with the goal of identifying genetic variants. (usually single nucleotide polymorphisms (SNPs)) that are associated with phenotypic traits such as disease status and drug response. The discordance of significantly associated ...

  10. Touring the Campus Library from the World Wide Web.

    Science.gov (United States)

    Mosley, Pixey Anne; Xiao, Daniel

    1996-01-01

    The philosophy, design, implementation and evaluation of a World Wide Web-accessible Virtual Library Tour of Texas A & M University's Evans Library is presented. Its design combined technical computer issues and library instruction expertise. The tour can be used to simulate a typical walking tour through the library or heading directly to a…

  11. Plesionika edwardsi (Brandt, 1851) is a marine species of wide ...

    African Journals Online (AJOL)

    spamer

    Plesionika edwardsi (Brandt, 1851) is a marine species of wide distribution at low latitudes. It is known from the Western Pacific (Philippines,. Indonesia), the Western Atlantic (from South. Carolina and North Bahamas to the Gulf of Mexico), the Eastern Atlantic (from North-West Spain to. Sierra Leone, including the ...

  12. The World Wide Web and the Television Generation.

    Science.gov (United States)

    Maddux, Cleborne D.

    1996-01-01

    The hypermedia nature of the World Wide Web may represent a true paradigm shift in telecommunications, but barriers exist to the Web having similar impact on education. Some of today's college students compare the Web with "bad TV"--lengthy pauses, links that result in error messages, and animation and sound clips that are too brief.…

  13. Open-Loop Wide-Bandwidth Phase Modulation Techniques

    Directory of Open Access Journals (Sweden)

    Nitin Nidhi

    2011-01-01

    Full Text Available The ever-increasing growth in the bandwidth of wireless communication channels requires the transmitter to be wide-bandwidth and power-efficient. Polar and outphasing transmitter topologies are two promising candidates for such applications, in future. Both these architectures require a wide-bandwidth phase modulator. Open-loop phase modulation presents a viable solution for achieving wide-bandwidth operation. An overview of prior art and recent approaches for phase modulation is presented in this paper. Phase quantization noise cancellation was recently introduced to lower the out-of-band noise in a digital phase modulator. A detailed analysis on the impact of timing and quantization of the cancellation signal is presented. Noise generated by the transmitter in the receive band frequency poses another challenge for wide-bandwidth transmitter design. Addition of a noise transfer function notch, in a digital phase modulator, to reduce the noise in the receive band during phase modulation is described in this paper.

  14. Mechatronic design exploration for wide format printing systems

    NARCIS (Netherlands)

    Bruijnen, D.J.H.

    2007-01-01

    This work aims at increasing the performance of Wide Format Printing Systems (WFPS) via a mechatronic approach. With increasing performance is meant that one or more of the categories: productivity, print quality, reliability and/or cost of production, is improved without sacrificing one of the

  15. Teaching Critical Evaluation Skills for World Wide Web Resources.

    Science.gov (United States)

    Tate, Marsha; Alexander, Jan

    1996-01-01

    Outlines a lesson plan used by an academic library to evaluate the quality of World Wide Web information. Discusses the traditional evaluation criteria of accuracy, authority, objectivity, currency, and coverage as it applies to the unique characteristics of Web pages: their marketing orientation, variety of information, and instability. The…

  16. An area wide control of fruit flies in Mauritius

    International Nuclear Information System (INIS)

    Sookar, P.; Permalloo, S.; Gungah, B.; Alleck, M.; Seewooruthun, S.I.; Soonnoo, A.R.

    2006-01-01

    An area-wide National Fruit Fly Control Programme (NFFCP) was initiated in 1994, funded by the European Union until 1999 and now fully financed by the Government of Mauritius. The NFFCP targets some 75,000 backyard fruit trees owners mainly. The bait application and male annihilation techniques (BAT e MAT) are currently being applied against the fruit flies attacking fleshy fruits and are targeting selected major fruit growing areas in the north, north-east, central and western parts of the island. Successful control has been achieved using these two techniques as demonstrated by trap catches and fruit samplings. The level of fruit fly damage to fruits has been reduced. Presently, the bait-insecticide mixture is being supplied free of charge to the public. The current status of the area-wide suppression programme is such that continuous use of BAT/MAT is a never ending process and as such is not viable. In this context, a TC project on Feasibility studies for integrated use of sterile insect technique for area wide tephritid fruit fly control.Studies are also being carried out on mass rearing of the peach fruit fly for small scale trials on SIT so as to eventually integrate this control method in our area-wide control programme. (author)

  17. Fracture Analysis of the FAA/NASA Wide Stiffened Panels

    Science.gov (United States)

    Seshadri, B. R.; Newman, J. C., Jr.; Dawicke, D. S.; Young, R. D.

    1999-01-01

    This paper presents the fracture analyses conducted on the FAA/NASA stiffened and unstiffened panels using the STAGS (STructural Analysis of General Shells) code with the critical crack-tip-opening angle (CTOA) fracture criterion. The STAGS code with the "plane-strain" core option was used in all analyses. Previous analyses of wide, flat panels have shown that the high-constraint conditions around a crack front, like plane strain, has to be modeled in order for the critical CTOA fracture criterion to predict wide panel failures from small laboratory tests. In the present study, the critical CTOA value was determined from a wide (unstiffened) panel with anti-buckling guides. The plane-strain core size was estimated from previous fracture analyses and was equal to about the sheet thickness. Rivet flexibility and stiffener failure was based on methods and criteria, like that currently used in industry. STAGS and the CTOA criterion were used to predict load-against-crack extension for the wide panels with a single crack and multiple-site damage cracking at many adjacent rivet holes. Analyses were able to predict stable crack growth and residual strength within a few percent (5%) of stiffened panel tests results but over predicted the buckling failure load on an unstiffened panel with a single crack by 10%.

  18. An area wide control of fruit flies in Mauritius

    Energy Technology Data Exchange (ETDEWEB)

    Sookar, P.; Permalloo, S.; Gungah, B.; Alleck, M.; Seewooruthun, S.I.; Soonnoo, A.R., E-mail: ento@intnet.m, E-mail: moa-entomology@mail.gov.m [Ministry of Agro Industry and Fisheries Reduit, Republic of Mauritius (Mauritius)

    2006-07-01

    An area-wide National Fruit Fly Control Programme (NFFCP) was initiated in 1994, funded by the European Union until 1999 and now fully financed by the Government of Mauritius. The NFFCP targets some 75,000 backyard fruit trees owners mainly. The bait application and male annihilation techniques (BAT e MAT) are currently being applied against the fruit flies attacking fleshy fruits and are targeting selected major fruit growing areas in the north, north-east, central and western parts of the island. Successful control has been achieved using these two techniques as demonstrated by trap catches and fruit samplings. The level of fruit fly damage to fruits has been reduced. Presently, the bait-insecticide mixture is being supplied free of charge to the public. The current status of the area-wide suppression programme is such that continuous use of BAT/MAT is a never ending process and as such is not viable. In this context, a TC project on Feasibility studies for integrated use of sterile insect technique for area wide tephritid fruit fly control.Studies are also being carried out on mass rearing of the peach fruit fly for small scale trials on SIT so as to eventually integrate this control method in our area-wide control programme. (author)

  19. Tim Berners-Lee, World Wide Web inventor

    CERN Multimedia

    1998-01-01

    The "Internet, Web, What's next?" conference on 26 June 1998 at CERN: Tim Berners-Lee, inventor of the World Wide Web and Director of the W3C, explains how the Web came to be and gave his views on the future.

  20. Genome-wide association study identifies five new schizophrenia loci

    NARCIS (Netherlands)

    Ripke, S.; Sanders, A. R.; Kendler, K. S.; Levinson, D. F.; Sklar, P.; Holmans, P. A.; Lin, D. Y.; Duan, J.; Ophoff, R. A.; Andreassen, O. A.; Scolnick, E.; Cichon, S.; St Clair, D.; Corvin, A.; Gurling, H.; Werge, T.; Rujescu, D.; Blackwood, D. H.; Pato, C. N.; Malhotra, A. K.; Purcell, S.; Dudbridge, F.; Neale, B. M.; Rossin, L.; Visscher, P. M.; Posthuma, D.; Ruderfer, D. M.; Fanous, A.; Stefansson, H.; Steinberg, S.; Mowry, B. J.; Golimbet, V.; de Hert, M.; Jonsson, E. G.; Bitter, I.; Pietilainen, O. P.; Collier, D. A.; Tosato, S.; Agartz, I.; Albus, M.; Alexander, M.; Amdur, R. L.; Amin, F.; Bass, N.; Bergen, S. E.; Black, D. W.; Borglum, A. D.; Brown, M. A.; Bruggeman, R.; Buccola, N. G.; Byerley, W. F.; Cahn, W.; Cantor, R. M.; Carr, V. J.; Catts, S. V.; Choudhury, K.; Cloninger, C. R.; Cormican, P.; Craddock, N.; Danoy, P. A.; Datta, S.; de Haan, L.; Demontis, D.; Dikeos, D.; Djurovic, S.; Donnely, P.; Donohoe, G.; Duong, L.; Dwyer, S.; Fink-Jensen, A.; Freedman, R.; Freimer, N. B.; Friedl, M.; Georgieva, L.; Giegling, I.; Gill, M.; Glenthoj, B.; Godard, S.; Hamshere, M.; Hansen, M.; Hartmann, A. M.; Henskens, F. A.; Hougaard, D. M.; Hultman, C. M.; Ingason, A.; Jablensky, A. V.; Jakobsen, K. D.; Jay, M.; Jurgens, G.; Kahn, R. S.; Keller, M. C.; Kenis, G.; Kenny, E.; Kim, Y.; Kirov, G. K.; Konnerth, H.; Konte, B.; Krabbendam, L.; Krasucki, R.; Lasseter, V. K.; Laurent, C.; Lawrence, J.; Lencz, T.; Lerer, F. B.; Liang, K. Y.; Lichtenstein, P.; Lieberman, J. A.; Linszen, D. H.; Lonnqvist, J.; Loughland, C. M.; Maclean, A. W.; Maher, B. S.; Maier, W.; Mallet, J.; Malloy, P.; Mattheisen, M.; Mattingsdal, M.; McGhee, K. A.; McGrath, J. J.; McIntosh, A.; McLean, D. E.; McQuillin, A.; Melle, I.; Michie, P. T.; Milanova, V.; Morris, D. W.; Mors, O.; Mortensen, P. B.; Moskvina, V.; Muglia, P.; Myin-Germeys, I.; Nertney, D. A.; Nestadt, G.; Nielsen, J.; Nikolov, I.; Nordentoft, M.; Norton, N.; Nothen, M. M.; O'Dushlaine, C. T.; Olincy, A.; Olsen, L.; O'Neill, F. A.; Orntoft, T. F.; Owen, M. J.; Pantelis, C.; Papadimitriou, G.; Pato, M. T.; Peltonen, L.; Petursson, H.; Pickard, B.; Pimm, J.; Pulver, A. E.; Puri, V.; Quested, D.; Quinn, E. M.; Rasmussen, H. B.; Rethelyi, J. M.; Ribble, R.; Rietschel, M.; Riley, B. P.; Ruggeri, M.; Schall, U.; Schulze, T. G.; Schwab, S. G.; Scott, R. J.; Shi, J.; Sigurdsson, E.; Silvermann, J. M.; Spencer, C. C.; Stefansson, K.; Strange, A.; Strengman, E.; Stroup, T. S.; Suvisaari, J.; Terenius, L.; Thirumalai, S.; Thygesen, J. H.; Timm, S.; Toncheva, D.; van den Oord, E.; van Os, J.; van Winkel, R.; Veldink, J.; Walsh, D.; Wang, A. G.; Wiersma, D.; Wildenauer, D. B.; Williams, H. J.; Williams, N. M.; Wormley, B.; Zammit, S.; Sullivan, P. F.; O'Donovan, M. C.; Daly, M. J.; Gejman, P. V.

    2011-01-01

    We examined the role of common genetic variation in schizophrenia in a genome-wide association study of substantial size: a stage 1 discovery sample of 21,856 individuals of European ancestry and a stage 2 replication sample of 29,839 independent subjects. The combined stage 1 and 2 analysis yielded