WorldWideScience

Sample records for screw-rod system utilizing

  1. The effect of different screw-rod design on the anti-rotational torque: a biomechanical comparison of three conventional screw-rod constructs.

    Science.gov (United States)

    Huang, Zifang; Wang, Chongwen; Fan, Hengwei; Sui, Wenyuan; Li, Xueshi; Wang, Qifei; Yang, Junlin

    2017-07-28

    Screw-rod constructs have been widely used to correct spinal deformities, but the effects of different screw-rod systems on anti-rotational torque have not been determined. This study aimed to analyze the biomechanical effect of different rod-screw constructs on anti-rotational torque. Three conventional spinal screw-rod systems (Legacy, RF-F-10 and USSII) were used to test the anti-rotational torque in the material test machine. ANOVA was performed to evaluate the anti-rotational capacity of different pedicle screws-rod constructs. The anti-rotational torque of Legacy group, RF-F-10 group and USSII group were 12.3 ± 1.9 Nm, 6.8 ± 0.4 Nm, and 3.9 ± 0.8 Nm, with a P value lower than 0.05. This results indicated that the Legacy screws-rod construct could provide a highest anti-rotation capacity, which is 68% and 210% greater than RF-F-10 screw-rod construct and USSII screw-rod respectively. The anti-rotational torque may be mainly affected by screw cap and groove design. Our result showed the anti-rotational torque are: Legacy system > RF-F-10 system > USSII system, suggesting that appropriate rod-screw constructs selection in surgery may be vital for anti-rotational torque improvement and preventing derotation correction loss.

  2. Stress analysis in a pedicle screw fixation system with flexible rods in the lumbar spine.

    Science.gov (United States)

    Kim, Kyungsoo; Park, Won Man; Kim, Yoon Hyuk; Lee, SuKyoung

    2010-01-01

    Breakage of screws has been one of the most common complications in spinal fixation systems. However, no studies have examined the breakage risk of pedicle screw fixation systems that use flexible rods, even though flexible rods are currently being used for dynamic stabilization. In this study, the risk of breakage of screws for the rods with various flexibilities in pedicle screw fixation systems is investigated by calculating the von Mises stress as a breakage risk factor using finite element analysis. Three-dimensional finite element models of the lumbar spine with posterior one-level spinal fixations at L4-L5 using four types of rod (a straight rod, a 4 mm spring rod, a 3 mm spring rod, and a 2 mm spring rod) were developed. The von Mises stresses in both the pedicle screws and the rods were analysed under flexion, extension, lateral bending, and torsion moments of 10 Nm with a follower load of 400 N. The maximum von Mises stress, which was concentrated on the neck region of the pedicle screw, decreased as the flexibility of the rod increased. However, the ratio of the maximum stress in the rod to the yield stress increased substantially when a highly flexible rod was used. Thus, the level of rod flexibility should be considered carefully when using flexible rods for dynamic stabilization because the intersegmental motion facilitated by the flexible rod results in rod breakage.

  3. Evaluation of the Effect of Fixation Angle between Polyaxial Pedicle Screw Head and Rod on the Failure of Screw-Rod Connection

    Directory of Open Access Journals (Sweden)

    Engin Çetin

    2015-01-01

    Full Text Available Introduction. Polyaxial screws had been only tested according to the ASTM standards (when they were perpendicularly positioned to the rod. In this study, effects of the pedicle screws angled fixation to the rod on the mechanical properties of fixation were investigated. Materials and Method. 30 vertically fixed screws and 30 screws fixed with angle were used in the study. Screws were used in three different diameters which were 6.5 mm, 7.0 mm, and 7.5 mm, in equal numbers. Axial pull-out and flexion moment tests were performed. Test results compared with each other using appropriate statistical methods. Results. In pull-out test, vertically fixed screws, in 6.5 mm and 7.0 mm diameter, had significantly higher maximum load values than angled fixed screws with the same diameters (P<0.01. Additionally, vertically fixed screws, in all diameters, had significantly greater stiffness according to corresponding size fixed with angle (P<0.005. Conclusion. Fixing the pedicle screw to the rod with angle significantly decreased the pull-out stiffness in all diameters. Similarly, pedicle screw instrumentation fixed with angle decreased the minimum sagittal angle between the rod and the screw in all diameters for flexion moment test but the differences were not significant.

  4. Biomechanics of lumbar cortical screw-rod fixation versus pedicle screw-rod fixation with and without interbody support.

    Science.gov (United States)

    Perez-Orribo, Luis; Kalb, Samuel; Reyes, Phillip M; Chang, Steve W; Crawford, Neil R

    2013-04-15

    Seven different combinations of posterior screw fixation, with or without interbody support, were compared in vitro using nondestructive flexibility tests. To study the biomechanical behavior of a new cortical screw (CS) fixation construct relative to the traditional pedicle screw (PS) construct. The CS is an alternative to the PS for posterior fixation of the lumbar spine. The CS trajectory is more sagittally and cranially oriented than the PS, being anchored in the pars interarticularis. Like PS fixation, CS fixation uses interconnecting rods fastened with top-locking connectors. Stability after bilateral CS fixation was compared with stability after bilateral PS fixation in the setting of intact disc and with direct lateral interbody fixation (DLIF) or transforaminal lateral interbody fixation (TLIF) support. Standard nondestructive flexibility tests were performed in cadaveric lumbar specimens, allowing non-paired comparisons of specific conditions from 28 specimens (4 groups of 7) within a larger experiment of multiple hardware configurations. Condition tested and group from which results originated were as follows: (1) intact (all groups); (2) with L3-L4 bilateral PS-rods (group 1); (3) with bilateral CS-rods (group 2); (4) with DLIF (group 3); (5) with DLIF + CS-rods (group 4); (6) with DLIF + PS-rods (group 3); (7) with TLIF + CS-rods (group 2), and (8) with TLIF + PS-rods (group 2). To assess spinal stability, the mean range of motion, lax zone, and stiff zone at L3-L4 were compared during flexion-extension, lateral bending, and axial rotation. With intact disc, stability was equivalent after PS-rod and CS-rod fixation, except that PS-rod fixation was stiffer during axial rotation. With DLIF support, there was no significant difference in stability between PS-rod and CS-rod fixation. With TLIF support, PS-rod fixation was stiffer than CS-rod fixation during lateral bending. Bilateral CS-rod fixation provided about the same stability in cadaveric specimens

  5. The biomechanical consequences of rod reduction on pedicle screws: should it be avoided?

    Science.gov (United States)

    Paik, Haines; Kang, Daniel G; Lehman, Ronald A; Gaume, Rachel E; Ambati, Divya V; Dmitriev, Anton E

    2013-11-01

    Rod contouring is frequently required to allow for appropriate alignment of pedicle screw-rod constructs. When residual mismatch is still present, a rod persuasion device is often used to achieve further rod reduction. Despite its popularity and widespread use, the biomechanical consequences of this technique have not been evaluated. To evaluate the biomechanical fixation strength of pedicle screws after attempted reduction of a rod-pedicle screw mismatch using a rod persuasion device. Fifteen 3-level, human cadaveric thoracic specimens were prepared and scanned for bone mineral density. Osteoporotic (n=6) and normal (n=9) specimens were instrumented with 5.0-mm-diameter pedicle screws; for each pair of comparison level tested, the bilateral screws were equal in length, and the screw length was determined by the thoracic level and size of the vertebra (35 to 45 mm). Titanium 5.5-mm rods were contoured and secured to the pedicle screws at the proximal and distal levels. For the middle segment, the rod on the right side was intentionally contoured to create a 5-mm residual gap between the inner bushing of the pedicle screw and the rod. A rod persuasion device was then used to engage the setscrew. The left side served as a control with perfect screw/rod alignment. After 30 minutes, constructs were disassembled and vertebrae individually potted. The implants were pulled in-line with the screw axis with peak pullout strength (POS) measured in Newton (N). For the proximal and distal segments, pedicle screws on the right side were taken out and reinserted through the same trajectory to simulate screw depth adjustment as an alternative to rod reduction. Pedicle screws reduced to the rod generated a 48% lower mean POS (495±379 N) relative to the controls (954±237 N) (p.05). In circumstances where a rod is not fully seated within the pedicle screw, the use of a rod persuasion device decreases the overall POS and work energy to failure of the screw or results in outright

  6. The pedicle screw-rod system is an acceptable method of reconstructive surgery after resection of sacroiliac joint tumours

    Directory of Open Access Journals (Sweden)

    Yi-Jun Zhou

    2016-03-01

    Full Text Available Hemipelvic resections for primary bone tumours require reconstruction to restore weight bearing along anatomic axes. However, reconstruction of the pelvic arch remains a major surgical challenge because of the high rate of associated complications. We used the pedicle screw-rod system to reconstruct the pelvis, and the purpose of this investigation was to assess the oncology, functional outcome and complication rate following this procedure. The purpose of this study was to investigate the operative indications and technique of the pedicle screw-rod system in reconstruction of the stability of the sacroiliac joint after resection of sacroiliac joint tumours. The average MSTS (Musculoskeletal Tumour Society score was 26.5 at either three months after surgery or at the latest follow-up. Seven patients had surgery-related complications, including wound dehiscence in one, infection in two, local necrosis in four (including infection in two, sciatic nerve palsy in one and pubic symphysis subluxation in one. There was no screw loosening or deep vein thrombosis occurring in this series. Using a pedicle screw-rod after resection of a sacroiliac joint tumour is an acceptable method of pelvic reconstruction because of its reduced risk of complications and satisfactory functional outcome, as well as its feasibility of reconstruction for type IV pelvis tumour resection without elaborate preoperative customisation. Level of evidence: Level IV, therapeutic study.

  7. Minimal access direct spondylolysis repair using a pedicle screw-rod system: a case series

    Directory of Open Access Journals (Sweden)

    Mohi Eldin Mohamed

    2012-11-01

    Full Text Available Abstract Introduction Symptomatic spondylolysis is always challenging to treat because the pars defect causing the instability needs to be stabilized while segmental fusion needs to be avoided. Direct repair of the pars defect is ideal in cases of spondylolysis in which posterior decompression is not necessary. We report clinical results using segmental pedicle-screw-rod fixation with bone grafting in patients with symptomatic spondylolysis, a modification of a technique first reported by Tokuhashi and Matsuzaki in 1996. We also describe the surgical technique, assess the fusion and analyze the outcomes of patients. Case presentation At Cairo University Hospital, eight out of twelve Egyptian patients’ acute pars fractures healed after conservative management. Of those, two young male patients underwent an operative procedure for chronic low back pain secondary to pars defect. Case one was a 25-year-old Egyptian man who presented with a one-year history of axial low back pain, not radiating to the lower limbs, after falling from height. Case two was a 29-year-old Egyptian man who presented with a one-year history of axial low back pain and a one-year history of mild claudication and infrequent radiation to the leg, never below the knee. Utilizing a standardized mini-access fluoroscopically-guided surgical protocol, fixation was established with two titanium pedicle screws place into both pedicles, at the same level as the pars defect, without violating the facet joint. The cleaned pars defect was grafted; a curved titanium rod was then passed under the base of the spinous process of the affected vertebra, bridging the loose fragment, and attached to the pedicle screw heads, to uplift the spinal process, followed by compression of the defect. The patients were discharged three days after the procedure, with successful fusion at one-year follow-up. No rod breakage or implant-related complications were reported. Conclusions Where there is no

  8. Clinical Outcomes of Posterior C1 and C2 Screw-Rod Fixation for Atlantoaxial Instability.

    Science.gov (United States)

    Işik, Hasan Serdar; Sandal, Evren; Çağli, Sedat

    2017-06-14

    In this study, we aimed at sharing our experiences and contributing to the literature by making a retrospective analysis of the patients we operated with screw-rod system for atlantoaxial instability in our clinic. Archive files of adult patients, who were operated for posterior C1-C2 stabilization with screw and rod in our clinic between January 2006 and January 2016, were analyzed. 28 patients, who had pre and post-operative images, follow-up forms and who were followed for at least one year, were analyzed. Preoperative clinical and radiological records, preoperative observations, postoperative complications, and clinical responses were evaluated. The average age of 28 patients (F:13 M:19) was 44.7 (21-73). Fixation was performed with C1-C2 screw-rod system on the basis of the following diagnoses; type 2 odontoid fracture (16), basilar invagination (5), C1-C2 instability (5), and atlantoaxial subluxation secondary to rheumatoid arthritis (2). Lateral mass screws were inserted at C1 segment. C2 screws inserted were bilateral pedicle in 12 cases, bilateral pars in 4, bilateral laminar in 8 and one side pars, one side laminar in 4 cases. There was no screw malposition. Neither implant failure nor recurrent instability was observed during follow-up. Significant clinical improvement was reported according to the assessments done with JOA and VAS scores. C1-C2 screw fixation is regarded as a more successful and safe method than other fixation methods in surgical treatment of atlantoaxial instability considering complications, success in reduction, fusion and fixation strength. C2 laminar screw technique is as successful as the other alternatives in fixation and fusion.

  9. Range of motion, sacral screw and rod strain in long posterior spinal constructs: a biomechanical comparison between S2 alar iliac screws with traditional fixation strategies.

    Science.gov (United States)

    Sutterlin, Chester E; Field, Antony; Ferrara, Lisa A; Freeman, Andrew L; Phan, Kevin

    2016-12-01

    S1 screw failure and L5/S1 non-union are issues with long fusions to S1. Improved construct stiffness and S1 screw offloading can help avoid this. S2AI screws have shown to provide similar stiffness to iliac screws when added to L3-S1 constructs. We sought to examine and compare the biomechanical effects on an L2-S1 pedicle screw construct of adding S2AI screws, AxiaLIF, L5-S1 interbody support via transforaminal lumbar interbody fusion (TLIF), and to examine the effect of the addition of cross connectors to each of these constructs. Two S1 screws and one rod with strain gauges (at L5/S1) were used in L2-S1 screw-rod constructs in 7 L1-pelvis specimens (two with low BMD). ROM, S1 screw and rod strain were assessed using a pure-moment flexibility testing protocol. Specimens were tested intact, and then in five instrumentation states consisting of: (I) Pedicle screws (PS) L2-S1; (II) PS + S2AI screws; (III) PS + TLIF L5/S1; (IV) PS + AxiaLIF L5/S1; (V) PS + S2AI + AxiaLIF L5/S1. The five instrumentation conditions were also tested with crosslinks at L2/3 and S1/2. Tests were conducted in flexion-extension, lateral bending and axial torsion with no compressive preload. S2A1 produces reduced S1 screw strain for flexion-extension, lateral bending and axial torsion, as well as reduced rod strain in lateral bending and axial torsion in comparison to AxiaLIF and interbody instrumentation, at the expense of increased rod flexion-extension strain. Cross-connectors may have a role in further reduction of S1 screw and rod strain. From a biomechanical standpoint, the use of the S2AI technique is at least equivalent to traditional iliac screws, but offers lower prominence and ease of assembly compared to conventional sacroiliac stabilization.

  10. A Universal Pedicle Screw and V-Rod System for Lumbar Isthmic Spondylolysis: A Retrospective Analysis of 21 Cases

    Science.gov (United States)

    Chen, Xiong-sheng; Zhou, Sheng-yuan; Jia, Lian-shun; Gu, Xiao-min; Fang, Lei; Zhu, Wei

    2013-01-01

    Objective To investigate the surgical outcome of a universal pedicle screw-V rod system and isthmic bone grafting for isthmic spondylolysis. Methods Twenty-four patients with isthmic spondylolysis at L5 and grade 0–I spondylolisthesis (Meyerding classification) received isthmic bone graft and stabilization using the universal pedicle screw-V rod system. Back pain was evaluated using the visual analog scale (VAS) and time to bone healing, improvement in spondylolisthesis and intervertebral space height at L5/S1 and L4/L5 were assessed. Results Twenty-one patients were followed up for 24 months and included in the analysis. Back pain was markedly improved at 3 months postoperatively with a statistical difference in VAS scores compared with preoperative VAS scores (Pspondylolysis and reduces back pain, prevents anterior displacement of the diseased segment and maintains intervertebral space height, thus offering a promising alternative to current approaches for isthmic spondylolysis. PMID:23691090

  11. Pedicle screw-rod fixation: a feasible treatment for dogs with severe degenerative lumbosacral stenosis.

    Science.gov (United States)

    Tellegen, Anna R; Willems, Nicole; Tryfonidou, Marianna A; Meij, Björn P

    2015-12-07

    Degenerative lumbosacral stenosis is a common problem in large breed dogs. For severe degenerative lumbosacral stenosis, conservative treatment is often not effective and surgical intervention remains as the last treatment option. The objective of this retrospective study was to assess the middle to long term outcome of treatment of severe degenerative lumbosacral stenosis with pedicle screw-rod fixation with or without evidence of radiological discospondylitis. Twelve client-owned dogs with severe degenerative lumbosacral stenosis underwent pedicle screw-rod fixation of the lumbosacral junction. During long term follow-up, dogs were monitored by clinical evaluation, diagnostic imaging, force plate analysis, and by using questionnaires to owners. Clinical evaluation, force plate data, and responses to questionnaires completed by the owners showed resolution (n = 8) or improvement (n = 4) of clinical signs after pedicle screw-rod fixation in 12 dogs. There were no implant failures, however, no interbody vertebral bone fusion of the lumbosacral junction was observed in the follow-up period. Four dogs developed mild recurrent low back pain that could easily be controlled by pain medication and an altered exercise regime. Pedicle screw-rod fixation offers a surgical treatment option for large breed dogs with severe degenerative lumbosacral stenosis with or without evidence of radiological discospondylitis in which no other treatment is available. Pedicle screw-rod fixation alone does not result in interbody vertebral bone fusion between L7 and S1.

  12. [Effectiveness of U-shape titanium screw-rod fixation system with bone autografting for lumbar spondylolysis of young adults].

    Science.gov (United States)

    Pu, Xiaobing; Yang, Shuangshi; Cao, Haiquan; Jing, Xingquan; Yin, Jun

    2014-03-01

    To investigate the effectiveness of U-shape titanium screw-rod fixation system with bone autografting for lumbar spondylolysis of young adults. Between January 2008 and December 2011, 32 patients with lumbar spondylolysis underwent U-shape titanium screw-rod fixation system with bone autografting. All patients were male with an average age of 22 years (range, 19-32 years). The disease duration ranged from 3 to 24 months (mean, 14 months). L3 was involved in spondylolysis in 2 cases, L4 in 10 cases, and L5 in 20 cases. The preoperative visual analogue scale (VAS) and Oswestry disability index (ODI) scores were 8.0 +/- 1.1 and 75.3 +/- 11.2, respectively. The operation time was 80-120 minutes (mean, 85 minutes), and the blood loss was 150-250 mL (mean, 210 mL). Primary healing of incision was obtained in all patients without complications of infection and nerve symptom. Thirty-two patients were followed up 12-24 months (mean, 14 months). Low back pain was significantly alleviated after operation. The VAS and ODI scores at 3 months after operation were 1.0 +/- 0.5 and 17.6 +/- 3.4, respectively, showing significant differences when compared with preoperative ones (t = 30.523, P = 0.000; t = 45.312, P = 0.000). X-ray films and CT showed bone fusion in the area of isthmus defects, with the bone fusion time of 6-12 months (mean, 9 months). During follow-up, no secondary lumbar spondyloly, adjacent segment degeneration, or loosening or breaking of internal fixator was found. The U-shape titanium screw-rod fixation system with bone autografting is a reliable treatment for lumbar spondylolysis of young adults because of a high fusion rate, minimal invasive, and maximum retention of lumbar range of motion.

  13. A universal pedicle screw and V-rod system for lumbar isthmic spondylolysis: a retrospective analysis of 21 cases.

    Directory of Open Access Journals (Sweden)

    Xiong-sheng Chen

    Full Text Available To investigate the surgical outcome of a universal pedicle screw-V rod system and isthmic bone grafting for isthmic spondylolysis.Twenty-four patients with isthmic spondylolysis at L5 and grade 0-I spondylolisthesis (Meyerding classification received isthmic bone graft and stabilization using the universal pedicle screw-V rod system. Back pain was evaluated using the visual analog scale (VAS and time to bone healing, improvement in spondylolisthesis and intervertebral space height at L5/S1 and L4/L5 were assessed.Twenty-one patients were followed up for 24 months and included in the analysis. Back pain was markedly improved at 3 months postoperatively with a statistical difference in VAS scores compared with preoperative VAS scores (P<0.001. The VAS scores were 0 to 3 at 6 months postoperatively in all patients and no back pain was reported in all patients except 2 patients who complained of back pain after prolonged sitting. X-ray examination showed a bone graft healing time of 3 to 12 months. Grade I spondylolisthesis improved to grade 0 in 4 patients and no noticeable change was observed in the remaining 17 cases. The intervertebral space height at L5/S1 was statistically increased (P<0.05 while no statistically significant change was seen at L4/L5. There was no statistically significant difference in the ROM of the intervertebral disks of L5/S1 and L4/5 before and after surgery.The universal pedicle screw-V rod system and isthmic bone grafting directly repairs isthmic spondylolysis and reduces back pain, prevents anterior displacement of the diseased segment and maintains intervertebral space height, thus offering a promising alternative to current approaches for isthmic spondylolysis.

  14. Effects of Multilevel Facetectomy and Screw Density on Postoperative Changes in Spinal Rod Contour in Thoracic Adolescent Idiopathic Scoliosis Surgery.

    Directory of Open Access Journals (Sweden)

    Terufumi Kokabu

    Full Text Available Flattening of the preimplantation rod contour in the sagittal plane influences thoracic kyphosis (TK restoration in adolescent idiopathic scoliosis (AIS surgery. The effects of multilevel facetectomy and screw density on postoperative changes in spinal rod contour have not been documented. This study aimed to evaluate the effects of multilevel facetectomy and screw density on changes in spinal rod contour from before implantation to after surgical correction of thoracic curves in patients with AIS prospectively. The concave and convex rod shapes from patients with thoracic AIS (n = 49 were traced prior to insertion. Postoperative sagittal rod shape was determined by computed tomography. The angle of intersection of the tangents to the rod end points was measured. Multiple stepwise linear regression analysis was used to identify variables independently predictive of change in rod contour (Δθ. Average Δθ at the concave and convex side were 13.6° ± 7.5° and 4.3° ± 4.8°, respectively. The Δθ at the concave side was significantly greater than that of the convex side (P < 0.0001 and significantly correlated with Risser sign (P = 0.032, the preoperative main thoracic Cobb angle (P = 0.031, the preoperative TK angle (P = 0.012, and the number of facetectomy levels (P = 0.007. Furthermore, a Δθ at the concave side ≥14° significantly correlated with the postoperative TK angle (P = 0.003, the number of facetectomy levels (P = 0.021, and screw density at the concave side (P = 0.008. Rod deformation at the concave side suggests that corrective forces acting on that side are greater than on the convex side. Multilevel facetectomy and/or screw density at the concave side have positive effects on reducing the rod deformation that can lead to a loss of TK angle postoperatively.

  15. Effect of screw position on single cycle to failure in bending and torsion of a locking plate-rod construct in a synthetic feline femoral gap model.

    Science.gov (United States)

    Niederhäuser, Simone K; Tepic, Slobodan; Weber, Urs T

    2015-05-01

    To evaluate the effect of screw position on strength and stiffness of a combination locking plate-rod construct in a synthetic feline femoral gap model. 30 synthetic long-bone models derived from beechwood and balsa wood. 3 constructs (2 locking plate-rod constructs and 1 locking plate construct; 10 specimens/construct) were tested in a diaphyseal bridge plating configuration by use of 4-point bending and torsion. Variables included screw position (near the fracture gap and far from the fracture gap) and application of an intramedullary pin. Constructs were tested to failure in each loading mode to determine strength and stiffness. Failure was defined as plastic deformation of the plate or breakage of the bone model or plate. Strength, yield angle, and stiffness were compared by use of a Wilcoxon test. Placement of screws near the fracture gap did not increase bending or torsional stiffness in the locking plate-rod constructs, assuming the plate was placed on the tension side of the bone. Addition of an intramedullary pin resulted in a significant increase in bending strength of the construct. Screw positioning did not have a significant effect on any torsion variables. Results of this study suggested that, in the investigated plate-rod construct, screw insertion adjacent to the fracture lacked mechanical advantages over screw insertion at the plate ends. For surgeons attempting to minimize soft tissue dissection, the decision to make additional incisions for screw placement should be considered with even more caution.

  16. History of Retractor Technologies for Percutaneous Pedicle Screw Fixation Systems.

    Science.gov (United States)

    Mobbs, Ralph J; Phan, Kevin

    2016-02-01

    Minimally invasive techniques aimed at minimizing surgery-associated risk and morbidity of spinal surgery have increased in popularity in recent years. Their potential advantages include reduced length of hospital stay, blood loss, and requirement for post-operative analgesia and earlier return to work. One such minimally invasive technique is the use of percutaneous pedicle screw fixation, which is paramount for promoting rigid and stable constructs and fusion in the context of trauma, tumors, deformity and degenerative disease. Percutaneous pedicle screw insertion can be an intimidating prospect for surgeons who have only been trained in open techniques. One of the ongoing challenges of this percutaneous system is to provide the surgeon with adequate access to the pedicle entry anatomy and adequate tactile or visual feedback concerning the position and anatomy of the rod and set-screw construct. This review article discusses the history and evolution of percutaneous pedicle screw retractor technologies and outlines the advances over the last decade in the rapidly expanding field of minimal access surgery for posterior pedicle screw based spinal stabilization. As indications for percutaneous pedicle screw techniques expand, the nuances of the minimally invasive surgery techniques and associated technologies will also multiply. It is important that experienced surgeons have access to tools that can improve access with a greater degree of ease, simplicity and safety. We here discuss the technical challenges of percutaneous pedicle screw retractor technologies and a variety of systems with a focus on the pros and cons of various retractor systems. © 2016 Chinese Orthopaedic Association and John Wiley & Sons Australia, Ltd.

  17. Biomechanical comparison between titanium and cobalt chromium rods used in a pedicle subtraction osteotomy model

    Directory of Open Access Journals (Sweden)

    Kalpit N. Shah

    2018-03-01

    Full Text Available Instrumentation failure is a common complication following complex spinal reconstruction and deformity correction. Rod fracture is the most frequent mode of hardware failure and often occurs at or near a 3-column osteotomy site. Titanium (Ti rods are commonly utilized for spinal fixations, however, theoretically stiffer materials, such as cobalt-chrome (CoCr rods are also available. Despite ongoing use in clinical practice, there is little biomechanical evidence that compares the construct ability to withstand fatigue stress for Ti and Co-Cr rods. Six models using 2 polyethylene blocks each were used to simulate a pedicle subtraction osteotomy. Within each block 6.0×45 mm polyaxial screws were placed and connected to another block using either two 6.0×100 mm Ti (3 models or CoCr rods (3 models. The rods were bent to 40° using a French bender and were secured to the screws to give a vertical height of 1.5 cm between the blocks. The blocks were fatigue tested with 700N at 4 Hz until failure. The average number of cycles to failure for the Ti rod models was 12840 while the CoCr rod models failed at a significantly higher, 58351 cycles (P=0.003. All Ti models experienced rod fracture as the mode of failure. Two out of the three CoCr models had rod fractures while the last sample failed via screw fracture at the screw-tulip junction. The risk of rod failure is substantial in the setting of long segment spinal arthrodesis and corrective osteotomy. Efforts to increase the mechanical strength of posterior constructs may reduce the occurrence of this complication. Utilizing CoCr rods in patients with pedicle subtraction osteotomy may reduce the rate of device failure during maturation of the posterior fusion mass and limit the need for supplemental anterior column support.

  18. Hollow Abutment Screw Design for Easy Retrieval in Case of Screw Fracture in Dental Implant System.

    Science.gov (United States)

    Sim, Bo Kyun; Kim, Bongju; Kim, Min Jeong; Jeong, Guk Hyun; Ju, Kyung Won; Shin, Yoo Jin; Kim, Man Yong; Lee, Jong-Ho

    2017-01-01

    The prosthetic component of dental implant is attached on the abutment which is connected to the fixture with an abutment screw. The abutment screw fracture is not frequent; however, the retrieval of the fractured screw is not easy, and it poses complications. A retrieval kit was developed which utilizes screw removal drills to make a hole on the fractured screw that provides an engaging drill to unscrew it. To minimize this process, the abutment screw is modified with a prefabricated access hole for easy retrieval. This study aimed to introduce this modified design of the abutment screw, the concept of easy retrieval, and to compare the mechanical strengths of the conventional and hollow abutment screws by finite element analysis (FEA) and mechanical test. In the FEA results, both types of abutment screws showed similar stress distribution in the single artificial tooth system. A maximum load difference of about 2% occurred in the vertical load by a mechanical test. This study showed that the hollow abutment screw may be an alternative to the conventional abutment screws because this is designed for easy retrieval and that both abutment screws showed no significant difference in the mechanical tests and in the FEA.

  19. Hollow Abutment Screw Design for Easy Retrieval in Case of Screw Fracture in Dental Implant System

    Directory of Open Access Journals (Sweden)

    Bo Kyun Sim

    2017-01-01

    Full Text Available The prosthetic component of dental implant is attached on the abutment which is connected to the fixture with an abutment screw. The abutment screw fracture is not frequent; however, the retrieval of the fractured screw is not easy, and it poses complications. A retrieval kit was developed which utilizes screw removal drills to make a hole on the fractured screw that provides an engaging drill to unscrew it. To minimize this process, the abutment screw is modified with a prefabricated access hole for easy retrieval. This study aimed to introduce this modified design of the abutment screw, the concept of easy retrieval, and to compare the mechanical strengths of the conventional and hollow abutment screws by finite element analysis (FEA and mechanical test. In the FEA results, both types of abutment screws showed similar stress distribution in the single artificial tooth system. A maximum load difference of about 2% occurred in the vertical load by a mechanical test. This study showed that the hollow abutment screw may be an alternative to the conventional abutment screws because this is designed for easy retrieval and that both abutment screws showed no significant difference in the mechanical tests and in the FEA.

  20. Hollow Abutment Screw Design for Easy Retrieval in Case of Screw Fracture in Dental Implant System

    Science.gov (United States)

    Kim, Bongju; Shin, Yoo Jin

    2017-01-01

    The prosthetic component of dental implant is attached on the abutment which is connected to the fixture with an abutment screw. The abutment screw fracture is not frequent; however, the retrieval of the fractured screw is not easy, and it poses complications. A retrieval kit was developed which utilizes screw removal drills to make a hole on the fractured screw that provides an engaging drill to unscrew it. To minimize this process, the abutment screw is modified with a prefabricated access hole for easy retrieval. This study aimed to introduce this modified design of the abutment screw, the concept of easy retrieval, and to compare the mechanical strengths of the conventional and hollow abutment screws by finite element analysis (FEA) and mechanical test. In the FEA results, both types of abutment screws showed similar stress distribution in the single artificial tooth system. A maximum load difference of about 2% occurred in the vertical load by a mechanical test. This study showed that the hollow abutment screw may be an alternative to the conventional abutment screws because this is designed for easy retrieval and that both abutment screws showed no significant difference in the mechanical tests and in the FEA. PMID:29065610

  1. An electromagnetic screw and nut system for operating vertical motions along an axis

    International Nuclear Information System (INIS)

    Fehr, Henri.

    1975-01-01

    This invention concerns a magnetic screw and nut system for operating control rods, designed for vertical mounting and having no mobile or slide contacts. It makes it possible to rotate a screw located inside a sealed tubular containment that can have a very thick wall. All the electromagnetic components entering into the operation are outside this containment. The magnetic screw has a constant air gap. The tube, manufactured of a non-magnetic material, includes two added annular pole pieces forming part of its wall and whose internal surfaces have a thread corresponding to that of the screw. The two annular pole pieces are spaced axially from each other by an amount equal to an integral number of thread pitches. An external winding and magnetic armature associated to these pole pieces form the fixed magnetic nut. A multiphase non-synchronous motor is placed around the tube and near the nut, the stator is external, the rotor is the screw. An appliance for fixing the degree of axial displacement freedom of the screw can be provided [fr

  2. Comparison of Direct Pars Repair Techniques of Spondylolysis in Pediatric and Adolescent Patients: Pars Compression Screw Versus Pedicle Screw-Rod-Hook.

    Science.gov (United States)

    Karatas, Ali F; Dede, Ozgur; Atanda, Alfred A; Holmes, Larry; Rogers, Kenneth; Gabos, Peter; Shah, Suken A

    2016-08-01

    Retrospective clinical cohort study. To compare the clinical and radiographic outcomes of patients who were treated with intrasegmental pars fixation by either laminar compression screw (LS) or a pedicle screw, rod, and laminar hook (PSRH) construct. Spondylolysis is a nonunion defect of the pars interarticularis. In symptomatic spondylolysis, direct repair of the pars interarticularis defect can preserve motion and prevent abnormal stresses at the adjacent levels. Sixteen patients who failed nonoperative treatment and underwent direct pars repair by using LS (n=9) or PSRH (n=7) constructs were included in the study. Clinical outcome was assessed by using the MacNab criteria. Radiologic fusion and complications were evaluated using plain radiographs or computed tomography images and patient charts. The healing rate was 100% after 6 months. The healing time was similar in both the groups: LS, 6.5 months; PSRH, 6.2 months. Patients with PSRH (5.9 mo) were more likely to return to sports earlier relative to patients with LS (7.7 mo). There were no complications in the LS group; in the PSRH group, 1 patient had mild sensory deficit and 2 had superficial wound infections. The MacNab criteria for pain assessment showed an excellent or good outcome in 8 of 9 patients in LS group and 6 of 7 patients in PSRH group. Relative to LS patients, there was a significant increase in surgical time and estimated blood loss among PSRH patients. Either of the mentioned 2 techniques appears to produce acceptable results. Biplanar fluoroscopy and navigation systems could minimize the risk of screw misplacement with LS construct. Familiarity with the various fixation techniques will allow the surgeon to select the most appropriate surgical technique.

  3. Surgical outcome of posterior decompression, posterolateral fusion and stabilization by pedicle screw and rod in thoracolumbar tuberculosis

    Directory of Open Access Journals (Sweden)

    Md. Anowarul Islam

    2017-05-01

    Full Text Available Spinal tuberculosis causes severe complications like neurological and spinal deformity which may lead to respiratory distress, costo-pelvic impingement, paraplegia and consequent reduction in the quality and longevity of life. The aim of the present treatment is to avoid the consequence of neural complications and gain near-normal spine. Mechanical factor causes pathological fracture or dislocation of an affected vertebral body. Surgical decompression ensues further instability. Reconstruction of spinal column by pedicle screw and rod provide stability and prevents secondary neural damage and deformity thereby helps in early mobilization. Prospective study was done to evaluate the results in 20 cases of spinal tuberculosis in thoracolumbar region associated with neurological deficit. We operated our cases (12 males and 8 females by posterolateral decompression, fusion and stabilization by pedicle screw and rod along with antitubercular drug treatment. All patients were with neurological deficit, single level involvement and 10 to 30 degree of mild kyphosis. After surgery, kyphosis improved from 20.7 ± 5.5 degrees to 12.5 ± 3.9 degree. Bony fusion was in 65.0% cases. Neurological improvement and pain subsided in all the patients.

  4. Hollow Abutment Screw Design for Easy Retrieval in Case of Screw Fracture in Dental Implant System

    OpenAIRE

    Sim, Bo Kyun; Kim, Bongju; Kim, Min Jeong; Jeong, Guk Hyun; Ju, Kyung Won; Shin, Yoo Jin; Kim, Man Yong; Lee, Jong-Ho

    2017-01-01

    The prosthetic component of dental implant is attached on the abutment which is connected to the fixture with an abutment screw. The abutment screw fracture is not frequent; however, the retrieval of the fractured screw is not easy, and it poses complications. A retrieval kit was developed which utilizes screw removal drills to make a hole on the fractured screw that provides an engaging drill to unscrew it. To minimize this process, the abutment screw is modified with a prefabricated access ...

  5. Microcomputer system for controlling fuel rod length

    International Nuclear Information System (INIS)

    Meyer, E.R.; Bouldin, D.W.; Bolfing, B.J.

    1979-01-01

    A system is being developed at the Oak Ridge National Laboratory (ORNL) to automatically measure and control the length of fuel rods for use in a high temperature gas-cooled reactor (HTGR). The system utilizes an LSI-11 microcomputer for monitoring fuel rod length and for adjusting the primary factor affecting length. Preliminary results indicate that the automated system can maintain fuel rod length within the specified limits of 1.940 +- 0.040 in. This system provides quality control documentation and eliminates the dependence of the current fuel rod molding process on manual length control. In addition, the microcomputer system is compatible with planned efforts to extend control to fuel rod fissile and fertile material contents

  6. Minimally Invasive Technique for PMMA Augmentation of Fenestrated Screws

    Directory of Open Access Journals (Sweden)

    Jan-Helge Klingler

    2015-01-01

    Full Text Available Purpose. To describe the minimally invasive technique for cement augmentation of cannulated and fenestrated screws using an injection cannula as well as to report its safety and efficacy. Methods. A total of 157 cannulated and fenestrated pedicle screws had been cement-augmented during minimally invasive posterior screw-rod spondylodesis in 35 patients from January to December 2012. Retrospective evaluation of cement extravasation and screw loosening was carried out in postoperative plain radiographs and thin-sliced triplanar computed tomography scans. Results. Twenty-seven, largely prevertebral cement extravasations were detected in 157 screws (17.2%. None of the cement extravasations was causing a clinical sequela like a new neurological deficit. One screw loosening was noted (0.6% after a mean follow-up of 12.8 months. We observed no cementation-associated complication like pulmonary embolism or hemodynamic insufficiency. Conclusions. The presented minimally invasive cement augmentation technique using an injection cannula facilitates convenient and safe cement delivery through polyaxial cannulated and fenestrated screws during minimally invasive screw-rod spondylodesis. Nevertheless, the optimal injection technique and design of fenestrated screws have yet to be identified. This trial is registered with German Clinical Trials DRKS00006726.

  7. Geothermal ORC Systems Using Large Screw Expanders

    OpenAIRE

    Biederman, Tim R.; Brasz, Joost J.

    2014-01-01

    Geothermal ORC Systems using Large Screw Expanders Tim Biederman Cyrq Energy Abstract This paper describes a low-temperature Organic Rankine Cycle Power Recovery system with a screw expander a derivative of developed of Kaishan's line of screw compressors, as its power unit. The screw expander design is a modified version of its existing refrigeration compressor used on water-cooled chillers. Starting the ORC development program with existing refrigeration screw compre...

  8. Effect of mixed alloy combinations on fretting corrosion performance of spinal screw and rod implants.

    Science.gov (United States)

    Mali, Sachin A; Singh, Vaneet; Gilbert, Jeremy L

    2017-07-01

    Spinal implants are made from a variety of materials to meet the unique mechanical demands of each application. However, the medical device community has raised concern about mixing dissimilar metals in an implant because of fear of inducing corrosion. There is a lack of systematic studies on the effects of mixing metals on performance of spinal implants, especially in fretting corrosion conditions. Hence, the goal was to determine whether mixing stainless steel (SS316L), titanium alloy (Ti6Al4V) and cobalt chromium (CoCrMo) alloy components in a spinal implant leads to any increased risk of corrosion degradation. Spinal constructs consisting of single assembly screw-connector-rod components were tested using a novel short-term cyclic fretting corrosion test method. A total of 17 alloy component combinations (comprised of SS316L, Ti6Al4V-anodized and CoCrMo alloy for rod, screws and connectors) were tested under three anatomic orientations. Spinal constructs having all SS316L were most susceptible to fretting-initiated crevice corrosion attack and showed higher average fretting currents (∼25 - 30 µA), whereas constructs containing all Ti6Al4V components were less susceptible to fretting corrosion with average fretting currents in the range of 1 - 6 µA. Mixed groups showed evidence of fretting corrosion but they were not as severe as all SS316L group. SEM results showed evidence of severe corrosion attack in constructs having SS316L components. There also did not appear to be any galvanic effects of combining alloys together. © 2016 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater, 105B: 1169-1177, 2017. © 2016 Wiley Periodicals, Inc.

  9. Control rod cluster with removable rods for nuclear fuel assembly

    International Nuclear Information System (INIS)

    Denizou, J.P.

    1989-01-01

    For each removable control rod, the open end section of the sleeve has a certain length of reduced diameter with openings in its wall. The top end of the rod is joined to an extension tube that surrounds the shaft over part of its lenght. This extension tube fits over the reduced part of the sleeve when the shaft is screwed into the bore of the sleeve. Rotation of the rod in the sleeve is prevented by deforming the extension tube locally in the openings of the end part of the sleeve. The rod is dismantled by exerting a torque on it using a gripping area near the end of the rod [fr

  10. Simple Technique for Removing Broken Pedicular Screws

    Directory of Open Access Journals (Sweden)

    A Agrawal

    2014-03-01

    Full Text Available The procedure for removing a broken pedicle screw should ideally be technically easy and minimally invasive, as any damage to the pedicle, during removal of the broken screw, may weaken the pedicle, thus compromising on the success of re-instrumentation. We describe the case of a 32-year old man who had undergone surgery for traumatic third lumbar vertebral body fracture three years prior to current admission and had developed the complication of pedicle screw breakage within the vertebral body. The patient underwent re-exploration and removal of the distal screws. Through a paravertebral incision and muscle separation, the screws and rods were exposed and the implants were removed.

  11. Improvement to the control rod drive of a nuclear reactor

    International Nuclear Information System (INIS)

    Desfontaines, Guy.

    1981-01-01

    Improvement to the devices that move the control rods of a nuclear reactor. The slow movements of the rods are generally carried out by screw and nut gear, the nut being blocked as to rotation and the screw as to translation movement. Additionally, a mechanism enables the control rods to be inserted rapidly by release of the screw and nut gear, the nut remaining constantly in gear with the screw. The presence of extra poles and coils under the stator of the actuating motor of the screw add length and weight to the mechanism and hence increase the strains and deformations which affect the latter in the event of an earthquake. The device of the invention makes it possible to overcome this drawback and leads to a more simple mechanism. It is characterized in that the rotor of the motor actuating the screw is also provided with clamps, in its high position, controlled by electromagnetic action as from the coils of the actuating motor stator so that they are in the closed position on the screw when the stator is powered and in the open position when it is no longer so, in order to allow the screw and nut assembly drop, and in that it includes a device to lock the clamps, enabling these to be kept in the open position when the control screw is not in the high holding position [fr

  12. A comparison of thermal algorithms of fuel rod performance code systems

    International Nuclear Information System (INIS)

    Park, C. J.; Park, J. H.; Kang, K. H.; Ryu, H. J.; Moon, J. S.; Jeong, I. H.; Lee, C. Y.; Song, K. C.

    2003-11-01

    The goal of the fuel rod performance is to identify the robustness of a fuel rod with cladding material. Computer simulation of the fuel rod performance becomes one of important parts to designed and evaluate new nuclear fuels and claddings. To construct a computing code system for the fuel rod performance, several algorithms of the existing fuel rod performance code systems are compared and are summarized as a preliminary work. Among several code systems, FRAPCON, and FEMAXI for LWR, ELESTRES for CANDU reactor, and LIFE for fast reactor are reviewed. Thermal algorithms of the above codes are investigated including methodologies and subroutines. This work will be utilized to construct a computing code system for dry process fuel rod performance

  13. A comparison of thermal algorithms of fuel rod performance code systems

    Energy Technology Data Exchange (ETDEWEB)

    Park, C. J.; Park, J. H.; Kang, K. H.; Ryu, H. J.; Moon, J. S.; Jeong, I. H.; Lee, C. Y.; Song, K. C

    2003-11-01

    The goal of the fuel rod performance is to identify the robustness of a fuel rod with cladding material. Computer simulation of the fuel rod performance becomes one of important parts to designed and evaluate new nuclear fuels and claddings. To construct a computing code system for the fuel rod performance, several algorithms of the existing fuel rod performance code systems are compared and are summarized as a preliminary work. Among several code systems, FRAPCON, and FEMAXI for LWR, ELESTRES for CANDU reactor, and LIFE for fast reactor are reviewed. Thermal algorithms of the above codes are investigated including methodologies and subroutines. This work will be utilized to construct a computing code system for dry process fuel rod performance.

  14. Effects of nonlinearity in the materials used for the semi-rigid pedicle screw systems on biomechanical behaviors of the lumbar spine after surgery

    International Nuclear Information System (INIS)

    Kim, Hyun; Lee, Sung-Jae; Lim, Do-Hyung; Oh, Hyun-Ju; Lee, Kwon-Yong

    2011-01-01

    Recently, various types of semi-rigid pedicle screw fixation systems have been developed for the surgical treatment of the lumbar spine. They were introduced to address the adverse issues commonly found in traditional rigid spinal fusion--abnormally large motion at the adjacent level and subsequent degeneration. The semi-rigid system uses more compliant materials (nitinol or polymers) and/or changes in rod design (coiled or twisted rods) as compared to the conventional rigid straight rods made of Ti alloys (E = 114 GPa, υ = 0.32). However, biomechanical studies on the semi-rigid pedicle screw systems were usually limited to linear modeling of the implant and anatomic elements, which may not be capable of reflecting realistic post-operative motions of the spine. In this study, we evaluated the effects of nonlinearity in materials used for semi-rigid pedicle screw fixation systems to evaluate the changes in biomechanical behaviors using finite element analysis. Changes in range of motion (ROM) and center of rotation (COR) were assessed at the operated and adjacent levels. Actual load-displacement results of the semi-rigid rod from mechanical test were carried out to reflect the nonlinearity of the implant. In addition, nonlinear material properties of various spinal ligaments studies were used for the finite element modeling. The post-operative models were constructed by modifying the previously validated intact model of the L1-S1 spine. Eight different post-operative models were made to address the effects of nonlinearity-with a traditional stiffness modulus rod (with linear ligaments, case 1; with nonlinear ligaments, case 5), with a rigid rod (with linear ligaments, case 2; with nonlinear ligaments, case 6), with a soft rod (with linear ligaments, case 3; with nonlinear ligaments, case 7), and with a nonlinear rod (with linear ligaments, case 4; with nonlinear ligaments, case 8). To simulate the load on the lumbar spine in a neutral posture, follower load (400 N

  15. BWR control rod drive scram pilot valve monitoring system

    International Nuclear Information System (INIS)

    Soden, R.A.; Kelly, V.

    1984-01-01

    The control rod drive system in a Boiling Water Reactor is the most important safety system in the power plant. All components of the system can be verified except the solenoid operated, scram pilot valves without scramming a rod. The pilot valve mechancial works is the weak link to the control rod drive system. These pilot valves control the hydraulic system which applies pressure to the ''insert'' side of the control rod piston and vents the ''withdraw'' side of the piston causing the rods to insert during a scam. The only verification that the valve is operating properly is to scram the rod. The concern for this portion of the system is demonstrated by the high number of redundant components and complete periodic testing of the electrical circuits. The pilot valve can become hung-up through wear, fracture of internal components, mechanical binding, foreign material or chemicals left in the valve during maintenance, etc. If the valve becomes hung-up the electrical tests performed will not indicate this condition and scramming the rod is in jeopardy. Only an attempt to scram a rod will indicate the hung-up valve. While this condition exists the rod is considered inoperative. This paper describes a system developed at a nuclear power plant that monitors the pilot valves on the control rod drive system. This system utilizes pattern recognition to assure proper internal workings of the scram pilot valves to plant operators. The system is totally automatic such that each time the valve is operated on a ''half scram'', a printout is available to the operator along with light indication that each of the 370 valves (on one unit of a BWR) is operating properly. With this monitoring system installed, all components of the control rod drive system including the solenoid pilot valves can be verified as operational without scramming any rods

  16. Mechanical components design for PWR - control rod drive mechanism

    International Nuclear Information System (INIS)

    Leme, Francisco Louzano; Mattar Neto, Miguel

    2002-01-01

    The Control Rod Drive Mechanism (CRDM) is usually - a high precision - equipment incorporating mechanical and electrical components designed to move the control rods. The 'control rods' refer to all rods or assemblies that are moved to assess the performance of the reactor. The CRDM here presented is the Nut and Lead Screw type. This type is basically a power screw type magnetically coupled to a slow speed reluctance electric motor that provides a means of axially positioning the movable fuel assemblies in the reactor core for purpose of controlling core reactivity. A helically threaded lead screw assembly, comprising one element of power screw, is attached to a movable fuel assemblies. The CRDM usually has closer and more consistent contact with environment peculiar to the reactor than has only other machinery component. This environment includes not only the radiation field of the reactor, but also the temperature, pressure and chemical properties associated with the material used as the coolant for reactor fuel. Specific and special materials are needed because of the above mentioned application. Due to the importance of the above described CRDM functions, this paper will also consider the nuclear functions and their safety classes as well as the CRDM nuclear design criteria. (author)

  17. Economics of water injected air screw compressor systems

    Science.gov (United States)

    Venu Madhav, K.; Kovačević, A.

    2015-08-01

    There is a growing need for compressed air free of entrained oil to be used in industry. In many cases it can be supplied by oil flooded screw compressors with multi stage filtration systems, or by oil free screw compressors. However, if water injected screw compressors can be made to operate reliably, they could be more efficient and therefore cheaper to operate. Unfortunately, to date, such machines have proved to be insufficiently reliable and not cost effective. This paper describes an investigation carried out to determine the current limitations of water injected screw compressor systems and how these could be overcome in the 15-315 kW power range and delivery pressures of 6-10 bar. Modern rotor profiles and approach to sealing and cooling allow reasonably inexpensive air end design. The prototype of the water injected screw compressor air system was built and tested for performance and reliability. The water injected compressor system was compared with the oil injected and oil free compressor systems of the equivalent size including the economic analysis based on the lifecycle costs. Based on the obtained results, it was concluded that water injected screw compressor systems could be designed to deliver clean air free of oil contamination with a better user value proposition than the oil injected or oil free screw compressor systems over the considered range of operations.

  18. Metallosis: A complication in the guided growing rod system used in treatment of scoliosis

    Directory of Open Access Journals (Sweden)

    Jae Hyuk Yang

    2017-01-01

    Full Text Available Soft tissue reaction following metallic debris formation with the use of guided growing rod system has not been previously reported in human. The purpose of this study is to report complications caused by metallosis in a guided growing rod system. A 9-year-old female patient, who underwent treatment for the progressive idiopathic scoliosis (with Cobb's angle of 71° with the guided growing rod system. Her Cobb's angle was corrected to 13° with the index surgery. During the 5 years postoperative period, she manifested recurrent episodes of skin irritation and progressive worsening of lateral curvature of the spine to an angle of 57°. Furthermore, at her final followup, Risser stage 4 with a gain in height of 26.4 cm was achieved. Considering adequate growth attainment and deterioration in the curvature, revision surgery with fusion was performed. Postoperative Cobb's angle of 23° was achieved with the final correction. During the revisional surgery, signs of implant wear and metallosis were observed at the location of the unconstrained screws. On histological evaluation, chronic inflammation with foreign body granules was seen. However, titanium level in the body was within normal range. She was discharged without any complications. More research on implant wear as a complication in the guided growing rod system is necessary before its widespread use. The occurrence of metallosis with the use of guided growing rod system in growing young children should be considered, when designing the implants.

  19. Device for driving control rods in a reactor

    International Nuclear Information System (INIS)

    Mizumura, Yasuhiro.

    1975-01-01

    Object: To lock and release scram rods by means of a notch and latch system and effect upward movement thereof by means of a screw shaft, the scramming operation being effected at a high speed, the adjusting shim being in inching mode. Structure: When a scram bar is moved toward outside by an actuator through a pin, the scram pin is disengaged from a scram guide and the guide moves down to disengage a latch from a notch and as a result, the scram rod is accelerated by a spring to be moved down, after which making of contact between a bellview washer and a shock stopper and making of contact between a snapper and a scram stopper cause a buffer condition to effect the scram operation. When the screw is rotated by a motor, the slider moves down to allow the reset latch to contact with the reset contact pin so that the latch comes into engagement with the notch to slowly move the scram rod upwardly. (Kamimura, M.)

  20. A digital position-indication system for control rods

    International Nuclear Information System (INIS)

    Nishizawa, Yukio; Hayakawa, Toshifumi

    1979-01-01

    Systems that detect and indicate the position of the control rods that regulate the thermal output of a nuclear reactor play a particularly important role in monitoring its operational status. Conventionally, control rod position indication in pressurized water reactors has been of the analog type, utilizing the principle of the differential transformer. The present digital system was developed with the objective of achieving greater stability, greater accuracy, and higher reliability. The article gives a general description of the system and describes its advantages. (author)

  1. Relationship of forces acting on implant rods and degree of scoliosis correction.

    Science.gov (United States)

    Salmingo, Remel Alingalan; Tadano, Shigeru; Fujisaki, Kazuhiro; Abe, Yuichiro; Ito, Manabu

    2013-02-01

    Adolescent idiopathic scoliosis is a complex spinal pathology characterized as a three-dimensional spine deformity combined with vertebral rotation. Various surgical techniques for correction of severe scoliotic deformity have evolved and became more advanced in applying the corrective forces. The objective of this study was to investigate the relationship between corrective forces acting on deformed rods and degree of scoliosis correction. Implant rod geometries of six adolescent idiopathic scoliosis patients were measured before and after surgery. An elasto-plastic finite element model of the implant rod before surgery was reconstructed for each patient. An inverse method based on Finite Element Analysis was used to apply forces to the implant rod model such that it was deformed the same after surgery. Relationship between the magnitude of corrective forces and degree of correction expressed as change of Cobb angle was evaluated. The effects of screw configuration on the corrective forces were also investigated. Corrective forces acting on rods and degree of correction were not correlated. Increase in number of implant screws tended to decrease the magnitude of corrective forces but did not provide higher degree of correction. Although greater correction was achieved with higher screw density, the forces increased at some level. The biomechanics of scoliosis correction is not only dependent to the corrective forces acting on implant rods but also associated with various parameters such as screw placement configuration and spine stiffness. Considering the magnitude of forces, increasing screw density is not guaranteed as the safest surgical strategy. Copyright © 2012 Elsevier Ltd. All rights reserved.

  2. Expert system for control rod programming of boiling water reactors

    International Nuclear Information System (INIS)

    Fukuzaki, T.; Yoshida, K.; Kobayashi, Y.; Matsuura, H.; Hoshi, K.

    1986-01-01

    Control rod programming, one of the main tasks in reactor core management of boiling water reactors (BWRs), can be successfully accomplished by well-experienced engineers. By use of core performance evaluation codes, their knowledge plays the main role in searching through optimal control rod patterns and exposure points for adjusting notch positions and exchanging rod patterns. An expert system has been developed, based on a method of knowledge engineering, to lighten the engineer's load in control rod programming. This system utilizes an inference engine suited for planning/designing problems, and stores the knowledge of well-experienced engineers in its knowledge base. In this report, the inference engine, developed considering the characteristics of the control rod programming, is introduced. Then the constitution and function of the expert system are discussed

  3. Control rod pattern exchange in a BWR/6 utilizing gang mode withdrawal

    International Nuclear Information System (INIS)

    Auvil, A.B. Jr.; Aldemir, T.; Hajek, B.K.

    1986-01-01

    The use of checkerboard pattern of alternating inserted and fully withdrawn control rods and the uneven void distribution in boiling water reactor (BWR) cores can cause large burnup gradients even after a short time of operation. To compensate for these effects, power has to be reshaped periodically (typically every two full-power months) by individually manipulating the control rods. During this manipulation process (called the control rod pattern exchange), the core power is reduced to 60% of nominal power by means of flow reduction to limit power swings to tolerable levels and to ensure that fuel thermal limits are not exceeded. A control rod pattern exchange by individual rod manipulation typically takes 4 to 8 h and represents a large cost burden to the utility in terms of reduced system output. The latest generation of BWRs, the BWR/6, possesses the capability to simultaneously move up to four symmetrically located control rods. The rods corresponding to a given gang may have rotational symmetry, mirror symmetry, or a combination of the two. This paper presents a pattern exchange procedure that exploits the capability of gang mode rod withdrawal to reduce the pattern exchange execution time and radial power distribution asymmetry associated with individual rod manipulation. The working model used in the study is the Perry Nuclear Power Plant Unit 1, located in Perry, Ohio, and owned by the Cleveland Electric Illuminating Company

  4. Transpedicular screw fixation in the thoracic and lumbar spine with a novel cannulated polyaxial screw system

    Directory of Open Access Journals (Sweden)

    Lutz Weise

    2008-10-01

    Full Text Available Lutz Weise, Olaf Suess, Thomas Picht, Theodoros KombosNeurochirurgische Klinik, Charité – Universitätsmedizin Berlin, Berlin, GermanyObjective: Transpedicular screws are commonly and successfully used for posterior fixation in spinal instability, but their insertion remains challenging. Even using navigation techniques, there is a misplacement rate of up to 11%. The aim of this study was to assess the accuracy of a novel pedicle screw system.Methods: Thoracic and lumbar fusions were performed on 67 consecutive patients for tumor, trauma, degenerative disease or infection. A total of 326 pedicular screws were placed using a novel wire-guided, cannulated, polyaxial screw system (XIA Precision®, Stryker. The accuracy of placement was assessed post operatively by CT scan, and the patients were followed-up clinically for a mean of 16 months.Results: The total medio-caudal pedicle wall perforation rate was 9.2% (30/326. In 19 of these 30 cases a cortical breakthrough of less than 2 mm occurred. The misplacement rate (defined as a perforation of 2 mm or more was 3.37% (11/326. Three of these 11 screws needed surgical revision due to neurological symptoms or CSF leakage. There have been no screw breakages or dislocations over the follow up-period.Conclusion: We conclude that the use of this cannulated screw system for the placement of pedicle screws in the thoracic and lumbar spine is accurate and safe. The advantages of this technique include easy handling without a time-consuming set up. Considering the incidence of long-term screw breakage, further investigation with a longer follow-up period is necessary.Keywords: spinal instrumentation, pedicle screws, misplacement, pedicle wall perforation

  5. Comparative Analysis of Effect of Density, Insertion Angle and Reinsertion on Pull-Out Strength of Single and Two Pedicle Screw Constructs Using Synthetic Bone Model

    OpenAIRE

    Krishnan, Venkatesh; Varghese, Vicky; Kumar, Gurunathan Saravana

    2016-01-01

    Study Design Biomechanical study. Purpose To determine the effect of density, insertion angle and reinsertion on pull-out strength of pedicle screw in single and two screw-rod configurations. Overview of Literature Pedicle screw pull-out studies have involved single screw construct, whereas two screws and rod constructs are always used in spine fusions. Extrapolation of results using the single screw construct may lead to using expensive implants or increasing the fusion levels specifically i...

  6. Control rod shutdown system

    International Nuclear Information System (INIS)

    Miyamoto, Yoshiyuki; Higashigawa, Yuichi.

    1996-01-01

    The present invention provides a control rod terminating system in a BWR type nuclear power plant, which stops an induction electric motor as rapidly as possible to terminate the control rods. Namely, the control rod stopping system controls reactor power by inserting/withdrawing control rods into a reactor by driving them by the induction electric motor. The system is provided with a control device for controlling the control rods and a control device for controlling the braking device. The control device outputs a braking operation signal for actuating the braking device during operation of the control rods to stop the operation of the control rods. Further, the braking device has at least two kinds of breaks, namely, a first and a second brakes. The two kinds of brakes are actuated by receiving the brake operation signals at different timings. The brake device is used also for keeping the control rods after the stopping. Even if a stopping torque of each of the breaks is small, different two kinds of brakes are operated at different timings thereby capable of obtaining a large stopping torque as a total. (I.S.)

  7. Screw engine used as an expander in ORC for low-potential heat utilization

    Science.gov (United States)

    Richter, Lukáš

    2017-09-01

    This paper deals with a screw motor that is used as an expander in an ORC (Organic Rankin Cycle) system, whose organic working substance allows the transformation of low-potential heat (waste heat, solar and geothermal energy) into electrical energy. The article describes the specific properties of an organic substance and a screw motor that must be considered when designing and assembling a complete power unit. Screw machines are not commonly used as expansion devices, so it is necessary to perform an analysis that makes it possible to adapt the screw machine to the expansion process in terms of profiling and design.

  8. Utilization of Screw Piles in High Seismicity Areas of Cold and Warm Permafrost

    Science.gov (United States)

    2010-07-01

    This work was performed in support of the AUTC project Utilization of Screw Piles in : High Seismicity Areas of Cold and Warm Permafrost under the direction of PI Dr. Kenan : Hazirbaba. Surface wave testing was performed at 30 sites in the City...

  9. Utilization of control rod drive (CRD) system for long term core cooling

    International Nuclear Information System (INIS)

    Huerta B, A.

    1991-01-01

    In this paper we consider an application of Probabilistic Risk Assessment (PRA) to risk management. Foreseeable risk management strategies to prevent core damage are constrained by the availability of first line systems as well as support systems. The actual trend in the evaluation of risk management options can be performed in a number of ways. An example is the identification of back-up systems which could be used to perform the same safety functions. In this work we deal with the evaluation of the feasibility, for BWR's, to use the Control Rod Drive system to maintain an adequate reactor core long term cooling in some accident sequences. This preliminary evaluation is carried out as a part of the Internal Events Analysis for Laguna Verde Nuclear Power Plant (LVNPP) that is currently under way by the Mexican Nuclear Regulatory Body. This analysis addresses the evaluation and incorporation of all the systems, including the safety related and the back-up non safety related systems, that are available for the operator in order to prevent core damage. As a part of this analysis the containment venting capability is also evaluated as a back-up of the containment heat removal function. This will prevent the primary containment overpressurization and loss of certain core cooling systems. A selection of accident sequences in which the Control Rod Drive system could be used to mitigate the accident and prevent core damage are discussed. A personal computer transient analysis code is used to carry out thermohydraulic simulations in order to evaluate the Control Rod Drive system performance, the corresponding results are presented. Finally, some preliminary conclusions are drawn. (author). 9 refs, 5 figs

  10. Conceptual design of ball-screw type control element drive mechanism

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Ji Ho; Kim, Jong In; Huh, Hyung [Korea Atomic Energy Research Institute, Taejon (Korea)

    1999-10-01

    In this report, the design features of ball-screw type CEDM with fine-step movement capability are described. The contents of this report are as follows: -Review of Design Requirements for Ball-screw type CEDM -System Description for Ball-screw type CEDM -Design of Ball Bearing and Ball-screw Assembly -Detail Design of Rotary Step Motor -Detail Design of Angular Position Indicator -Materials. The Ball-screw type CEDM described in this report is to be utilized as the starting point for design development of CEDM for SMART. 11 refs., 43 figs., 3 tabs. (Author)

  11. Safety rod driving device

    International Nuclear Information System (INIS)

    Murakami, Kiyonobu; Kurosaki, Akira.

    1988-01-01

    Purpose: To rapidly insert safety rods for a criticality experiment device into a reactor core container to stop the criticality reaction thereby prevent reactivity accidents. Constitution: A cylinder device having a safety rod as a cylinder rod attached with a piston at one end is constituted. The piston is elevated by pressurized air and attracted and fixed by an electromagnet which is a stationary device disposed at the upper portion of the cylinder. If the current supply to the electromagnet is disconnected, the safety rod constituting the cylinder rod is fallen together with the piston to the lower portion of the cylinder. Since the cylinder rod driving device has neither electrical motor nor driving screw as in the conventional device, necessary space can be reduced and the weight is decreased. In addition, since the inside of the nuclear reactor can easily be shielded completely from the external atmosphere, leakage of radioactive materials can be prevented. (Horiuchi, T.)

  12. Linear motion device and method for inserting and withdrawing control rods

    International Nuclear Information System (INIS)

    Smith, J. E.

    1984-01-01

    A linear motion device, more specifically a control rod drive mechanism (CRDM) for inserting and withdrawing control rods into a reactor core, is capable of independently and sequentially positioning two sets of control rods with a single motor stator and rotor. The CRDM disclosed can control more than one control rod lead screw without incurring a substantial increase in the size of the mechanism

  13. Sucker rod motor

    Energy Technology Data Exchange (ETDEWEB)

    Radzalov, N N; Radzhabov, N A

    1983-01-01

    The motor consists of rollers mounted on the wellmouth and connected by a flexible rink. Reciprocating mechanism is in the form of a horizontal non-mobile single-side operation cylinder, inside which a plunger and rod are mounted. The working housing of the hydrocylinder is connected to a gas-hydr aulic batter, and when running is connected via plunger to the high pressure source; running in reverse it is connected with a safety valve and automatic control unit. The unit is equipped with a reducer and a mechanical transformer consisting of screw and nut, and which is shutoff with a single-side lining. The plunger rod consists of an auger-like unit. The high pressure source is provided by the injection line of the sucker rod that has been equipped with a reverse valve.

  14. A Novel Pedicle Screw with Mobile Connection: A Pilot Study

    Directory of Open Access Journals (Sweden)

    Yasuaki Tokuhashi

    2014-01-01

    Full Text Available To prevent adjacent disc problems after spinal fusion, a pedicle screw with a mobile junction between the head and threaded shaft was newly developed. The threaded shaft of the screw has 10 degrees mobility in all directions, but its structure is to prevent abnormal translation and tilting. This screw was evaluated as follows: (1 endurance test: 106 times rotational stress was applied; (2 biological reactions: novel screws with a mobile head and conventional screws with a fixed head were inserted into the bilateral pedicles of the L3, L4, and L5 in two mini pigs with combination. Eight months after surgery, vertebral units with the screw rod constructs were collected. After CT scan, the soft and bony tissues around the screws were examined grossly and histologically. As a result, none of the screws broke during the endurance test stressing. The mean amount of abrasion wear was 0.0338 g. In the resected mini pig section, though zygapophyseal joints between fixed-head screws showed bony union, the amount of callus in the zygapophyseal joints connected with mobile-head screws was small, and joint space was confirmed by CT. No metalloses were noted around any of the screws. Novel screws were suggested to be highly durable and histologically safe.

  15. Economics of water injected air screw compressor systems

    OpenAIRE

    Madhav, K. V.; Kovacevic, A.

    2015-01-01

    There is a growing need for compressed air free of entrained oil to be used in industry. In many cases it can be supplied by oil flooded screw compressors with multi stage filtration systems, or by oil free screw compressors. However, if water injected screw compressors can be made to operate reliably, they could be more efficient and therefore cheaper to operate. Unfortunately, to date, such machines have proved to be insufficiently reliable and not cost effective. This paper describes an in...

  16. A simple method for in vivo measurement of implant rod three-dimensional geometry during scoliosis surgery.

    Science.gov (United States)

    Salmingo, Remel A; Tadano, Shigeru; Fujisaki, Kazuhiro; Abe, Yuichiro; Ito, Manabu

    2012-05-01

    Scoliosis is defined as a spinal pathology characterized as a three-dimensional deformity of the spine combined with vertebral rotation. Treatment for severe scoliosis is achieved when the scoliotic spine is surgically corrected and fixed using implanted rods and screws. Several studies performed biomechanical modeling and corrective forces measurements of scoliosis correction. These studies were able to predict the clinical outcome and measured the corrective forces acting on screws, however, they were not able to measure the intraoperative three-dimensional geometry of the spinal rod. In effect, the results of biomechanical modeling might not be so realistic and the corrective forces during the surgical correction procedure were intra-operatively difficult to measure. Projective geometry has been shown to be successful in the reconstruction of a three-dimensional structure using a series of images obtained from different views. In this study, we propose a new method to measure the three-dimensional geometry of an implant rod using two cameras. The reconstruction method requires only a few parameters, the included angle θ between the two cameras, the actual length of the rod in mm, and the location of points for curve fitting. The implant rod utilized in spine surgery was used to evaluate the accuracy of the current method. The three-dimensional geometry of the rod was measured from the image obtained by a scanner and compared to the proposed method using two cameras. The mean error in the reconstruction measurements ranged from 0.32 to 0.45 mm. The method presented here demonstrated the possibility of intra-operatively measuring the three-dimensional geometry of spinal rod. The proposed method could be used in surgical procedures to better understand the biomechanics of scoliosis correction through real-time measurement of three-dimensional implant rod geometry in vivo.

  17. Pulsed eddy current inspection system for nondestructive examination of irradiated fuel rods

    International Nuclear Information System (INIS)

    Yancey, M.E.

    1979-01-01

    An inspection system has been developed for nondestructive examination of irradiated fuel rods utilizing pulsed eddy current techniques. The system employs an encircling type pulsed eddy current transducer capable of sensing small defects located on both the inner and outer diameter fuel rod surfaces during a single scan. Pulsed eddy current point probes are used to provide fuel rod wall thikness data and an indication of radial defect location. Two linear variable differential transformers are used to provide information on fuel rod diameter variation. A microprocessor based control system is used to automatically scan fuel rods up to 4.06 meters in length at predetermined radial locations. Defects as small as 0.005 cm deep by 0.254 cm long by 0.005 cm wide have been detected on outside diameter surfaces of a 1.43 cm outside diameter fuel rod cladding with a 0.094 cm wall thickness and 0.010 cm deep by 0.254 cm long by 0.005 cm wide on the inside diameter surface

  18. Linear motion device and method for inserting and withdrawing control rods

    Science.gov (United States)

    Smith, J.E.

    Disclosed is a linear motion device and more specifically a control rod drive mechanism (CRDM) for inserting and withdrawing control rods into a reactor core. The CRDM and method disclosed is capable of independently and sequentially positioning two sets of control rods with a single motor stator and rotor. The CRDM disclosed can control more than one control rod lead screw without incurring a substantial increase in the size of the mechanism.

  19. Development of the automatic control rod operation system for JOYO. Verification of automatic control rod operation guide system

    International Nuclear Information System (INIS)

    Terakado, Tsuguo; Suzuki, Shinya; Kawai, Masashi; Aoki, Hiroshi; Ohkubo, Toshiyuki

    1999-10-01

    The automatic control rod operation system was developed to control the JOYO reactor power automatically in all operation modes(critical approach, cooling system heat up, power ascent, power descent), development began in 1989. Prior to applying the system, verification tests of the automatic control rod operation guide system was conducted during 32nd duty cycles of JOYO' from Dec. 1997 to Feb. 1998. The automatic control rod operation guide system consists of the control rod operation guide function and the plant operation guide function. The control rod operation guide function provides information on control rod movement and position, while the plant operation guide function provide guidance for plant operations corresponding to reactor power changes(power ascent or power descent). Control rod insertion or withdrawing are predicted by fuzzy algorithms. (J.P.N.)

  20. MIS Single-position Lateral and Oblique Lateral Lumbar Interbody Fusion and Bilateral Pedicle Screw Fixation: Feasibility and Perioperative Results.

    Science.gov (United States)

    Blizzard, Daniel J; Thomas, J Alex

    2018-03-15

    Retrospective review of prospectively collected data of the first 72 consecutive patients treated with single-position one- or two-level lateral (LLIF) or oblique lateral interbody fusion (OLLIF) with bilateral percutaneous pedicle screw and rod fixation by a single spine surgeon. To evaluate the clinical feasibility, accuracy, and efficiency of a single-position technique for LLIF and OLLIF with bilateral pedicle screw and rod fixation. Minimally-invasive lateral interbody approaches are performed in the lateral decubitus position. Subsequent repositioning prone for bilateral pedicle screw and rod fixation requires significant time and resources and does not facilitate increased lumbar lordosis. The first 72 consecutive patients (300 screws) treated with single-position LLIF or OLLIF and bilateral pedicle screws by a single surgeon between December 2013 and August 2016 were included in the study. Screw accuracy and fusion were graded using computed tomography and several timing parameters were recorded including retractor, fluoroscopy, and screw placement time. Complications including reoperation, infection, and postoperative radicular pain and weakness were recorded. Average screw placement time was 5.9 min/screw (standard deviation, SD: 1.5 min; range: 3-9.5 min). Average total operative time (interbody cage and pedicle screw placement) was 87.9 minutes (SD: 25.1 min; range: 49-195 min). Average fluoroscopy time was 15.0 s/screw (SD: 4.7 s; range: 6-25 s). The pedicle screw breach rate was 5.1% with 10/13 breaches measured as < 2 mm in magnitude. Fusion rate at 6-months postoperative was 87.5%. Two (2.8%) patients underwent reoperation for malpositioned pedicle screws with subsequent resolution of symptoms. The single-position, all-lateral technique was found to be feasible with accuracy, fluoroscopy usage, and complication rates comparable with the published literature. This technique eliminates the time and staffing associated with

  1. Inspection system for Zircaloy clad fuel rods

    International Nuclear Information System (INIS)

    Yancey, M.E.; Porter, E.H.; Hansen, H.R.

    1975-10-01

    A description is presented of the design, development, and performance of a remote scanning system for nondestructive examination of fuel rods. Characteristics that are examined include microcracking of fuel rod cladding, fuel-cladding interaction, cladding thickness, fuel rod diameter variation, and fuel rod bowing. Microcracking of both the inner and outer fuel rod surfaces and variations in wall thickness are detected by using a pulsed eddy current technique developed by Argonne National Laboratory (ANL). Fuel rod diameter variation and fuel rod bowing are detected by using two linear variable differential transformers (LVDTs) and a signal conditioning system. The system's mechanical features include variable scanning speeds, a precision indexing system, and a servomechanism to maintain proper probe alignment. Initial results indicate that the system is a very useful mechanism for characterizing irradiated fuel rods

  2. Fuel Rod Consolidation Project: Phase 2, Final report: Volume 1

    International Nuclear Information System (INIS)

    1987-01-01

    This design report describes the NUS final design of the Prototype Spent Nuclear Fuel Rod Consolidation System. This summary presents the approach and the subsequent sections describe, in detail, the final design. Detailed data, drawings, and the design Basis Accident Report are provided in Volumes II thru V. The design as presented, represents one cell of a multicell facility for the dry consolidation of any type of PWR and BWR fuel used in the United States LWR industry that will exceed 1% of the fuel inventory at the year 2000. The system contains the automatically-controlled equipment required to consolidate 750MT (heavy metal)/year, at 75% availability. The equipment is designed as replaceable components using state-of-the-art tchnology. The control system utilizes the most advanced commercially available equipment on the market today. Two state-of-the-art advanced servo manipulators are provided for system maintenance. In general the equipment is designed utilizing fabricated and commercial components. For example, the main drive systems use commercially available roller screws. These rollers screws have 60,000 hours of operation in nuclear power plants and have been used extensively in other applications. The motors selected represent the most advanced designed servo motors on the market today for the precision control of machinery. In areas where precise positioning was not required, less expensive TRW Globe motors were selected. These are small compact motors with a long history of operations in radiation environments. The Robotic Bridge Transporters are modified versions of existing bridge cranes for remote automatic operations. Other equipment such as the welder for fuel canister closure operations is a commercially available product with an operating history applicable to this process. In general, this approach was followed throughout the design of all the equipment and will enable the system to be developed without costly development programs

  3. [Development of polyaxial locking plate screw system of sacroiliac joint].

    Science.gov (United States)

    Fan, Weijie; Xie, Xuesong; Zhou, Shuping; Zhang, Yonghu

    2014-09-01

    To develop an instrument for sacroiliac joint fixation with less injury and less complications. Firstly, 18 adult pelvic specimens (8 males and 10 females) were used to measure the anatomical data related to the locking plates and locking screws on the sacrum and ilium, and the polyaxial locking plate screw system of the sacroiliac joint was designed according to the anatomic data. This system was made of medical titanium alloy. Then 4 adult male plevic specimens were harvested and the experiment was divided into 3 groups: group A (normal pelvic), group B (the dislocated sacroiliac joint fixed with sacroiliac screws), and group C (the dislocated sacroiliac joint fixed with polyaxial locking plate screw system). The vertical displacement of sacroiliac joint under the condition of 0-700 N vertical load and the horizontal displacement on angle under the condition of 0-12 N·m torsional load were compared among the 3 groups by using the biological material test system. Finally, the simulated application test was performed on 1 adult male cadaveric specimen to observe soft tissue injury and the position of the locking plate and screw by X-ray films. According to the anatomic data of the sacrum and ilium, the polyaxial locking plate screw system of the sacroiliac joint was designed. The biomechanical results showed that the vertical displacement of the sacroiliac joint under the condition of 0-700 N vertical load in group A was significantly bigger than that in group B and group C (P 0.05). The horizontal displacement on angle under the condition of 0-12 N·m torsional load in group A was significantly less than that in group B and group C (P 0.05). The test of simulating application showed that the specimen suffered less soft tissue injury, and this instrument could be implanted precisely and safely. The polyaxial locking plate screw system of the sacroiliac joint has the advantages of smaller volume and less injury; polyaxial fixation enables flexible adjustment screw

  4. Biofilm formation on titanium alloy and anatase-Bactercline® coated titanium healing screws: an in vivo human study

    Directory of Open Access Journals (Sweden)

    Antonio Scarano

    2013-03-01

    Full Text Available Aim Bacterial adherence to implants is considered to be an important event in the pathogenesis of bacterial infections. In fact, this infection process is a first stage of peri-implant mucositis and peri-implantitis, and a positive correlation has been found between oral hygiene and marginal bone loss around implants in the edentulous mandible. Surface properties of transgingival implant components are important determinants in bacterial adhesion. The purpose of this study was to characterize the biofilm formation, in vivo, on healing screws made of titanium alloy or coated with a combination of anatase and Bactercline® product. Materials and methods Twenty-five patients, between 21- 37 years, in excellent systemic health, participated in this study. In each of the 25 participants, one anatase-Bactercline® coated healing screw (Test and one titanium alloy (TI6Al4V healing screw (Control were adapted to two different implants. Quantitative and qualitative biofilm formation on healing abutments was analyzed by culture method.Results Bacterial adherence to the two different healing screws used in this study were compared. Statistically significant differences were found between the Control and the Test group for both aerobic and anaerobic bacterial counts (p<0,05. The microflora consisted both of Gram-positive and Gram-negative bacteria, and displayed a high variability. The anaerobic S. intermedius, potentially “pathogenic”, was isolated only from the Control group. Both healing screws harbored primarily Gram-positive rods as Actinomyces spp, A. naeslundii, A. viscosus and the Gram-negative rods (Fusobacterium spp, Prevotella spp, Capnocythophaga spp were mostly found on the Control healing screws.Conclusion Anatase-Bactercline® coated healing screws reduce the number of initially adhering bacteria, formed mainly of Gram-positive microorgnisms, while, on the contrary, the microflora covering the titanium alloy healing screws was, for the

  5. Hydraulic system for the drive of control rod

    International Nuclear Information System (INIS)

    Niwano, Masao.

    1978-01-01

    Purpose: To remove thermal stress and improve safety by utilizing water discharged a driving device as a part of cooling water for the device upon driving of control rods. Constitution: A water drain valve is wholly closed and a flow stabilization valve is supplied with an amount of water necessary for driving control rods. Upon driving one control rod, an amount of water required for the driving is caused to flow to the relivant hydraulic control unit and the flow rate in the stabilization valve is reduced by an amount required for the driving to keep the flow rate constant in the flow control valve. Since Excess water conventionally returned to the pressure vessel is utilized as cooling water for the driving device of control rods, the pressure vessel nozzle can be saved. Accordingly, the thermal stress in the nozzle portion can be removed to significantly improve the safety. (Seki, T.)

  6. Control of influence of a thread on a bending of screws

    International Nuclear Information System (INIS)

    Proskuriakov, N E; Lopa, I V; Trapeznikov, E V

    2017-01-01

    The influence of the threads and the bending of screw on their moments of inertia of the cross section considered. This problem is actual since existing methods exclude from calculations the influence of supporting the thread, using as the basic geometrical parameter such as the internal diameter of the thread (diameter of cavities). Fundamental difference of a bend of the screw from a bend of a smooth rod consists that moment of inertia of the screw is a variable. It is shown that the change in cross-section moment of inertia along the length of the screw are essential and have periodic character. Analytical interrelation of the bending of the screw and the decreasing of moment of inertia of its cross section is established and equation describing this phenomenon is suggested. The greatest decrease of the moment of inertia occurs in the middle of the screw length, and the lowest - at its ends. Function and approximate coefficients for the main types of thread are proposed, which take into account this change. (paper)

  7. Use of Supplemental Short Pre-Contoured Accessory Rods and Cobalt Chrome Alloy Posterior Rods Reduces Primary Rod Strain and Range of Motion Across the Pedicle Subtraction Osteotomy Level

    DEFF Research Database (Denmark)

    Hallager, Dennis Winge; Gehrchen, Poul Martin; Dahl, Benny

    2016-01-01

    and rod strain is necessary to determine the biomechanical efficacy of these techniques. METHODS: Five specimens (T12-S1) underwent PSO at L3 with pedicle screw stabilization at L1-S1. Pedicle subtraction was adjusted to achieve a final lordosis of 70°. Flexion-extension (FE), lateral bending, and axial...

  8. RodPilotR - The Innovative and Cost-Effective Digital Control Rod Drive Control System for PWRs

    International Nuclear Information System (INIS)

    Baron, Clemens

    2008-01-01

    With RodPilot, AREVA NP offers an innovative and cost-effective system for controlling control rods in Pressurized Water Reactors. RodPilot controls the three operating coils of the control rod drive mechanism (lift, moveable gripper and stationary gripper coil). The rods are inserted into or withdrawn from the core as required by the Reactor Control System. The system combines modern components, state-of-the-art logic and a proven electronic control rod drive control principle to provide enhanced reliability and lower maintenance costs. (author)

  9. Ultrasonic Structural Health Monitoring to Assess the Integrity of Spinal Growing Rods In Vitro.

    Science.gov (United States)

    Oetgen, Matthew E; Goodley, Addison; Yoo, Byungseok; Pines, Darryll J; Hsieh, Adam H

    2016-01-01

    Rod fracture is a common complication of growing rods and can result in loss of correction, patient discomfort, and unplanned revision surgery. The ability to quantitate rod integrity at each lengthening would be advantageous to avoid this complication. We investigate the feasibility of applying structural health monitoring to evaluate the integrity of growing rods in vitro. Single-rod titanium 4.5-mm growing rod constructs (n = 9), one screw proximally and one distally connected by in-line connectors, were assembled with pedicle screws fixed in polyethylene blocks. Proximal and distal ends were loaded and constructs subjected to cyclic axial compression (0-100 N at 1 Hz), with incrementally increasing maximum compressive loads of 10 N every 9k cycles until failure. Four piezoceramic transducers (PZTs) were mounted along the length the constructs to interrogate the integrity of the rods with an ultrasonic, guided lamb wave approach. Every 9k cycles, an 80 V excitatory voltage was applied to a PZT to generate high-frequency vibrations, which, after propagating through the construct, was detected by the remaining PZTs. Amplitude differences between pre- and postload waveform signals were calculated until rod failure. Average construct lifetime was 88,991 ± 13,398 cycles. All constructs failed due to rod fracture within 21 mm (mean = 15 ± 4.5 mm) of a screw or connector. Amplitude differences between pre- and postload increased in a stepwise fashion as constructs were cycled. Compared to baseline, we found a 1.8 ± 0.6-fold increase in amplitude 18k cycles before failure, a 2.2 ± 1.0-fold increase in amplitude 9k cycles before failure, and a 2.75 ± 1.5-fold increase in amplitude immediately before rod fracture. We describe a potential method for assessing the structural integrity of growing rods using ultrasonic structural health monitoring. These preliminary data demonstrate the ability of periodic rod assessment to detect structural changes in cycled growing

  10. Fabrication Of Control Rod System Of The RSG-GAS

    International Nuclear Information System (INIS)

    Sudirdjo, Hari; Setyono; Prasetya, Hendra

    2001-01-01

    Eight units of control rod mechanical system of RSG-GAS has been fabricated. The control rod mechanical system of RSG-GAS consist of guide tube and lifting rod. Complete construction of the control rod mechanical system of RSG-GAS are guide tube, lifting rod, absorber, and absorber casing. The eight units of the control rod mechanical system of RSG-GAS has been fabricated according to the mechanical engineering design

  11. Thermocouple pressure bushing in suspension rod

    International Nuclear Information System (INIS)

    Pasek, J.; Ondreicka, K.

    1975-01-01

    The seal is described of jacket thermocouples located in the pressure reducer in the fuel element suspension rod. The thermocouples are sealed in the pressure reducer with a silicon sealing compound. The sealing compound is compressed between the two reducers with a Bellevile spring and a pressure washer secured in position with a spring. The axial pressure of the inner parts of the reducer on the compound is adjustable by means of a thrust screw. The tightness and alignment of the thermocouples in the pressure reducer is achieved by tightening the thrust screw to the stop of the top reducer and the subsequent setting of the sealing compound. (J.B.)

  12. Individual nuclear fuel rod weighing system

    International Nuclear Information System (INIS)

    Fogg, J. L.; Howell, C. A.; Smith, J. H.; Vining, G. E.

    1985-01-01

    An individual nuclear fuel rod weighing system for rods carried on a tray which moves along a materials handling conveyor. At a first tray position on the conveyor, a lifting device raises the rods off the tray and places them on an overhead ramp. A loading mechanism conveys the rods singly from the overhead ramp onto an overhead scale for individual weighing. When the tray is at a second position on the conveyor, a transfer apparatus transports each weighed rod from the scale back onto the tray

  13. Screw-System-Based Mobility Analysis of a Family of Fully Translational Parallel Manipulators

    Directory of Open Access Journals (Sweden)

    Ernesto Rodriguez-Leal

    2013-01-01

    Full Text Available This paper investigates the mobility of a family of fully translational parallel manipulators based on screw system analysis by identifying the common constraint and redundant constraints, providing a case study of this approach. The paper presents the branch motion-screws for the 3-RP̲C-Y parallel manipulator, the 3-RCC-Y (or 3-RP̲RC-Y parallel manipulator, and a newly proposed 3-RP̲C-T parallel manipulator. Then the paper determines the sets of platform constraint-screws for each of these three manipulators. The constraints exerted on the platforms of the 3-RP̲C architectures and the 3-RCC-Y manipulators are analyzed using the screw system approach and have been identified as couples. A similarity has been identified with the axes of couples: they are perpendicular to the R joint axes, but in the former the axes are coplanar with the base and in the latter the axes are perpendicular to the limb. The remaining couples act about the axis that is normal to the base. The motion-screw system and constraint-screw system analysis leads to the insightful understanding of the mobility of the platform that is then obtained by determining the reciprocal screws to the platform constraint screw sets, resulting in three independent instantaneous translational degrees-of-freedom. To validate the mobility analysis of the three parallel manipulators, the paper includes motion simulations which use a commercially available kinematics software.

  14. Individual nuclear fuel rod weighing system

    International Nuclear Information System (INIS)

    Fogg, J.L.; Smith, J.H.; Vining, G.E.; Howell, C.A.

    1985-01-01

    An individual nuclear fuel rod weighing system for rods carried on a tray which moves along a materials handling conveyor is discussed. At a first tray position on the conveyor, a lifting device raises the rods off the tray and places them on an overhead ramp. A loading mechanism conveys the rods singly from the overhead ramp onto an overhead scale for individual weighing. When the tray is at a second position on the conveyor, a transfer apparatus transports each weighed rod from the scale back onto the tray

  15. Study on pedicle screw fixation of cervical spine assisted CT-based navigation system compared with the individual cervical peddle screws placement technique

    International Nuclear Information System (INIS)

    He Xishun; Yang Huilin; Zhu Ruofu; Tan Xiangqi; Wang Genlin; Tang Tiansi

    2008-01-01

    Objective: To explore a safe and effective method for placing the cervical pedicle screws. Methods: There were ten adult cadaver specimens of cervica spine (C 1 -C 7 ) with intact structures including ligament and perivertebral muscles. The spiral computed tomography scan (Elscint CT Twin flash) at the section of 1 mm and three-dimensional reconstruction of all 10 cervical specimens were taken. By CT scan, the parameters of the cervical pedicles were measure,Then taking randomly 5 cervical specimens, according to the CT measurements, an appropriate screw was inserted into pedicle individually. In the other 5 human cadaver cervical vertebraes, Φ3.5 mm screws were inserted into the C 2 -C 7 pedicles by assisted by CT-based navigation system. Cortical integrity of every sample was examined by anatomic dissection, the spiral computed tomography scan and arrows,and coronal reconstruction. Results: Sixty screws was inserted into pedicle individually, and the achievement ratio was 90%, the perfectness ratio was 75%, 60 screws was placed into pedicle assisted by CT-based navigation system, and the achievement ratio was 96.6%, the perfectness ratio was 90%. By chi-square test for statistical analysis, there were no statistical significance between the accuracy rate of two methods(P>0.05). However there was statistical significance between the perfectness ratio between two methods(P<0.05). Conclusion: Compared with the individual cervical peddle screws placement technique, the perfectness ratio of pedicle screw fixation of cervical spine assisted by CT-based navigation system is higher, but there are no significant difference in accuracy. (authors)

  16. RodPilot{sup R} - The Innovative and Cost-Effective Digital Control Rod Drive Control System for PWRs

    Energy Technology Data Exchange (ETDEWEB)

    Baron, Clemens [AREVA NP GmbH, NLEE-G, Postfach 1199, 91001 Erlangen (Germany)

    2008-07-01

    With RodPilot, AREVA NP offers an innovative and cost-effective system for controlling control rods in Pressurized Water Reactors. RodPilot controls the three operating coils of the control rod drive mechanism (lift, moveable gripper and stationary gripper coil). The rods are inserted into or withdrawn from the core as required by the Reactor Control System. The system combines modern components, state-of-the-art logic and a proven electronic control rod drive control principle to provide enhanced reliability and lower maintenance costs. (author)

  17. Intrasacral rod fixation for pediatric lumbopelvic fusion.

    Science.gov (United States)

    Ilharreborde, Brice; Mazda, Keyvan

    2014-07-01

    This paper reports the authors' 19 years experience with pediatric intrasacral rod fixation. After insertion of two cannulated screws in S1 with and an original template guiding them into the anterior third of the endplate, two short fusion rods were inserted into the sacrum according to Jackson's technique distally to S3. In neuromuscular scoliosis, pelvic obliquity was reduced by connecting the proximal and distal constructs, distraction or compression, and in situ rod bending. In children with high-grade spondylolisthesis, lumbosacral kyphosis was reduced by rotation of the sacrum and in situ bending. There were no direct neurological or vascular injuries. The main complication was infection (7%). No pseudarthrosis or significant loss of correction at the lumbosacral junction was observed during follow-up. Intrasacral rod fixation appears to be safe and reliable for lumbopelvic fusion in pediatric patients.

  18. Investigation of a Ball Screw Feed Drive System Based on Dynamic Modeling for Motion Control

    Directory of Open Access Journals (Sweden)

    Yi-Cheng Huang

    2017-06-01

    Full Text Available This paper examines the frequency response relationship between the ball screw nut preload, ball screw torsional stiffness variations and table mass effect for a single-axis feed drive system. Identification for the frequency response of an industrial ball screw drive system is very important for the precision motion when the vibration modes of the system are critical for controller design. In this study, there is translation and rotation modes of a ball screw feed drive system when positioning table is actuated by a servo motor. A lumped dynamic model to study the ball nut preload variation and torsional stiffness of the ball screw drive system is derived first. The mathematical modeling and numerical simulation provide the information of peak frequency response as the different levels of ball nut preload, ball screw torsional stiffness and table mass. The trend of increasing preload will indicate the abrupt peak change in frequency response spectrum analysis in some mode shapes. This study provides an approach to investigate the dynamic frequency response of a ball screw drive system, which provides significant information for better control performance when precise motion control is concerned.

  19. Rodded shutdown system for a nuclear reactor

    International Nuclear Information System (INIS)

    Golden, M.P.; Govi, A.R.

    1978-01-01

    A top mounted nuclear reactor diverse rodded shutdown system utilizing gas fed into a pressure bearing bellows region sealed at the upper extremity to an armature is described. The armature is attached to a neutron absorber assembly by a series of shafts and connecting means. The armature is held in an uppermost position by an electromagnet assembly or by pressurized gas in a second embodiment. Deenergizing the electromagnet assembly, or venting the pressurized gas, causes the armature to fall by the force of gravity, thereby lowering the attached absorber assembly into the reactor core

  20. Sensory systems for a control rod position using reed switches for the integral reactor

    International Nuclear Information System (INIS)

    Yu, J. Y.; Choi, S.; Kim, J. H.; Lee, D. J.

    2007-01-01

    shaft of the rotary step motor. The permanent magnet positioned in the planetary gear holder which is designed to rotate of 60 degree in corresponding to each step of the rotary step motor. Therefore the angular position detector can measure one step angular increase of the rotary step motor by means of detecting the angular position of the permanent magnet using the reed switch assembly outside the pressure housing of the angular position detector. The angular position detector with planetary gear can measure precisely the control rod position by considering the gear ratio and the ball screw lead as well as can check the operating condition of the rotary step motor of CEDM at real time. The two sensory systems of the position indicator and the angular position detector will cooperate to measure the position of the control rod more reliably

  1. Screw-in forces during instrumentation by various file systems.

    Science.gov (United States)

    Ha, Jung-Hong; Kwak, Sang Won; Kim, Sung-Kyo; Kim, Hyeon-Cheol

    2016-11-01

    The purpose of this study was to compare the maximum screw-in forces generated during the movement of various Nickel-Titanium (NiTi) file systems. Forty simulated canals in resin blocks were randomly divided into 4 groups for the following instruments: Mtwo size 25/0.07 (MTW, VDW GmbH), Reciproc R25 (RPR, VDW GmbH), ProTaper Universal F2 (PTU, Dentsply Maillefer), and ProTaper Next X2 (PTN, Dentsply Maillefer, n = 10). All the artificial canals were prepared to obtain a standardized lumen by using ProTaper Universal F1. Screw-in forces were measured using a custom-made experimental device (AEndoS- k , DMJ system) during instrumentation with each NiTi file system using the designated movement. The rotation speed was set at 350 rpm with an automatic 4 mm pecking motion at a speed of 1 mm/sec. The pecking depth was increased by 1 mm for each pecking motion until the file reach the working length. Forces were recorded during file movement, and the maximum force was extracted from the data. Maximum screw-in forces were analyzed by one-way ANOVA and Tukey's post hoc comparison at a significance level of 95%. Reciproc and ProTaper Universal files generated the highest maximum screw-in forces among all the instruments while M-two and ProTaper Next showed the lowest ( p files with smaller cross-sectional area for higher flexibility is recommended.

  2. Evaluation of apical root resorption in orthodontic patients with maxillary anterior intrusion using utility arches and mini screws: A comparative clinical trial

    Directory of Open Access Journals (Sweden)

    Muraleedhara Bhat

    2014-01-01

    Full Text Available Objectives: The purpose of this study was to compare the amount of apical root resorption in orthodontic patients undergoing maxillary anterior intrusion using utility arches and mini screws; and to compare the efficacy of mini screws and utility arches in reducing over bite. Materials and Methods: The study sample consisted of 20 patients, divided in two groups. Group A consisted of ten patients in whom titanium mini-screws were used Group B consisted of 10 patients in whom utility arches made of 0.017 × 0.25" TMA were used. Diagnostic records (study models and radiovisiography [RVG] were taken at 2 time intervals, T1 (just before implant/utility arch placement and T2 (at the end of intrusion 6 months later. The pre and post radiographic images were measured from incisal tip to the root apex with the help of intrascan DC software. Root resorption was computed as the difference between the pre-treatment total tooth length and the post treatment total tooth length. These values were subjected to statistical analyses using SPSS 16.00 statistical software. (Statistical Package for the Social Sciences, IBM Corporation, December 2007 Results: The results showed that root resorption was seen in both groups. Amount of resorption seen was higher in mini implant group than utility arch group. Mini implants were more efficient in reducing the overbite when compared to utility arches. Conclusion: It was concluded from the study that intrusion using mini implant resulted in more root resorption than utility arch; and mini implant was more effective in intruding the incisors than utility arch.

  3. Aging assessment of BWR control rod drive systems

    International Nuclear Information System (INIS)

    Greene, R.H.

    1991-01-01

    This study examines the aging phenomena associated with boiling water reactor (BWR) control rod drive mechanisms (CRDMs) and assess the merits of various methods of managing this aging. Information for this study was acquired from (1) the results of a special CRDM aging questionnaire distributed to each US BWR utility, (2) a first-of-its-kind workshop held to discuss CRDM aging and maintenance concerns, (3) an analysis of Nuclear Plant Reliability Data System (NPRDS) failure cases attributed to the CRD system, and (4) personal information exchange with industry experts. As part of this study, nearly 3500 NPRDS failure reports have been analyzed to examine the prevailing failure trends for CRD system components. An investigation was conducted to summarize the occurrence frequency of these component failures, discovery methods, reported failure causes, their respective symptoms, and actions taken by utilities to restore component and system service. The results of this research have identified the predominant CRDM failure modes and causes. In addition, recommendations are presented that identify specific actions utilities can implement to mitigate CRDM aging. An evaluation has also been made of certain maintenance practices and tooling which have enabled some utilities to reduce ALARA exposures received from routine CRDM replacement and rebuilding activities. 5 refs., 8 figs., 2 tabs

  4. Scoliosis corrective force estimation from the implanted rod deformation using 3D-FEM analysis.

    Science.gov (United States)

    Abe, Yuichiro; Ito, Manabu; Abumi, Kuniyoshi; Sudo, Hideki; Salmingo, Remel; Tadano, Shigeru

    2015-01-01

    Improvement of material property in spinal instrumentation has brought better deformity correction in scoliosis surgery in recent years. The increase of mechanical strength in instruments directly means the increase of force, which acts on bone-implant interface during scoliosis surgery. However, the actual correction force during the correction maneuver and safety margin of pull out force on each screw were not well known. In the present study, estimated corrective forces and pull out forces were analyzed using a novel method based on Finite Element Analysis (FEA). Twenty adolescent idiopathic scoliosis patients (1 boy and 19 girls) who underwent reconstructive scoliosis surgery between June 2009 and Jun 2011 were included in this study. Scoliosis correction was performed with 6mm diameter titanium rod (Ti6Al7Nb) using the simultaneous double rod rotation technique (SDRRT) in all cases. The pre-maneuver and post-maneuver rod geometry was collected from intraoperative tracing and postoperative 3D-CT images, and 3D-FEA was performed with ANSYS. Cobb angle of major curve, correction rate and thoracic kyphosis were measured on X-ray images. Average age at surgery was 14.8, and average fusion length was 8.9 segments. Major curve was corrected from 63.1 to 18.1 degrees in average and correction rate was 71.4%. Rod geometry showed significant change on the concave side. Curvature of the rod on concave and convex sides decreased from 33.6 to 17.8 degrees, and from 25.9 to 23.8 degrees, respectively. Estimated pull out forces at apical vertebrae were 160.0N in the concave side screw and 35.6N in the convex side screw. Estimated push in force at LIV and UIV were 305.1N in the concave side screw and 86.4N in the convex side screw. Corrective force during scoliosis surgery was demonstrated to be about four times greater in the concave side than in convex side. Averaged pull out and push in force fell below previously reported safety margin. Therefore, the SDRRT maneuver was

  5. Thermal Analysis of Ball screw Systems by Explicit Finite Difference Method

    Energy Technology Data Exchange (ETDEWEB)

    Min, Bog Ki [Hanyang Univ., Seoul (Korea, Republic of); Park, Chun Hong; Chung, Sung Chong [KIMM, Daejeon (Korea, Republic of)

    2016-01-15

    Friction generated from balls and grooves incurs temperature rise in the ball screw system. Thermal deformation due to the heat degrades positioning accuracy of the feed drive system. To compensate for the thermal error, accurate prediction of the temperature distribution is required first. In this paper, to predict the temperature distribution according to the rotational speed, solid and hollow cylinders are applied for analysis of the ball screw shaft and nut, respectively. Boundary conditions such as the convective heat transfer coefficient, friction torque, and thermal contact conductance (TCC) between balls and grooves are formulated according to operating and fabrication conditions of the ball screw. Explicit FDM (finite difference method) is studied for development of a temperature prediction simulator. Its effectiveness is verified through numerical analysis.

  6. Polyetheretherketone (PEEK) rods: short-term results in lumbar spine degenerative disease.

    Science.gov (United States)

    Colangeli, S; Barbanti Brodàno, G; Gasbarrini, A; Bandiera, S; Mesfin, A; Griffoni, C; Boriani, S

    2015-06-01

    Pedicle screw and rod instrumentation has become the preferred technique for performing stabilization and fusion in the surgical treatment of lumbar spine degenerative disease. Rigid fixation leads to high fusion rates but may also contribute to stress shielding and adjacent segment degeneration. Thus, the use of semirigid rods made of polyetheretherketone (PEEK) has been proposed. Although the PEEK rods biomechanical properties, such as anterior load sharing properties, have been shown, there are few clinical studies evaluating their application in the lumbar spine surgical treatment. This study examined a retrospective cohort of patients who underwent posterior lumbar fusion for degenerative disease using PEEK rods, in order to evaluate the clinical and radiological outcomes and the incidence of complications.

  7. Verification test of control rod system for HTR-10

    International Nuclear Information System (INIS)

    Zhou Huizhong; Diao Xingzhong; Huang Zhiyong; Cao Li; Yang Nianzu

    2002-01-01

    There are 10 sets of control rods and driving devices in 10 MW High Temperature Gas-cooled Test Reactor (HTR-10). The control rod system is the controlling and shutdown system of HTR-10, which is designed for reactor criticality, operation, and shutdown. In order to guarantee technical feasibility, a series of verification tests were performed, including room temperature test, thermal test, test after control rod system installed in HTR-10, and test of control rod system before HTR-10 first criticality. All the tests data showed that driving devices working well, control rods running smoothly up and down, random position settling well, and exactly position indicating

  8. Nuclear reactor fuel rod attachment system

    International Nuclear Information System (INIS)

    Christiansen, D.W.

    1983-01-01

    The invention involves a technique to quickly, inexpensively and rigidly attach a nuclear reactor fuel rod to a support member. The invention also allows for the repeated non-destructive removal and replacement of the fuel rod. The proposed fuel rod and support member attachment and removal system consists of a locking cap fastened to the fuel rod and a locking strip fastened to the support member or vice versa. The locking cap has two or more opposing fingers shaped to form a socket. The fingers spring back when moved apart and released. The locking strip has an extension shaped to rigidly attach to the socket's body portion

  9. Aging assessment of BWR control rod drive systems

    International Nuclear Information System (INIS)

    Greene, R.H.

    1992-01-01

    This Phase 1 Nuclear Plant Aging Research (NPAR) study examines the aging phenomena associated with boiling water reactor (BWR) control rod drive mechanisms (CRDMs) and assesses the merits of various methods of managing this aging. Information for this study was acquired from (1) the results of a special CRDM aging questionnaire distributed to each US BWR utility, (2) a first-of-its-kind workshop held to discuss CRDM aging and maintenance concerns, (3) an analysis of NPRDS failure cases attributed to the CRD system, and (4) personal information exchange. As part of this study, nearly 3,500 NPRDS failure reports have been analyzed to examine the prevailing failure trends for CRD system components. An investigation has been conducted that summarizes the occurrence frequency of these component failures, discovery methods, reported failure causes, their respective symptoms, and actions taken by utilities to restore component and system service. The results of this research have identified the predominant CRDM failure modes and causes. In addition, recommendations are presented regarding specific actions that utilities can implement to mitigate CRDM aging. An evaluation has also been made of certain practices and tooling which have enabled some utilities to reduce ALARA exposures received from routine CRDM replacement and rebuilding activities

  10. Aging assessment of BWR control rod drive systems

    International Nuclear Information System (INIS)

    Greene, R.H.

    1991-01-01

    This Phase 1 Nuclear Plant Aging Research (NPAR) study examines the aging phenomena associated with boiling water reactor (BWR) control rod drive mechanisms (CRDMs) and assesses the merits of various methods of managing this aging. Information for this study was acquired from (1) the results of a special CRDM aging questionnaire distributed to each US BWR utility, (2) a first-of-its-kind workshop held to discuss CRDM aging and maintenance concerns, (3) an analysis of NPRDS failure cases attributed to the CRD system, and (4) personal information exchange. As part of this study, nearly 3,500 NPRDS failure reports have been analyzed to examine the prevailing failure trends for CRD system components. An investigation has been conducted that summarizes the occurrence frequency of these component failures, discovery methods, reported failure causes, their respective symptoms, and actions taken by utilities to restore component and system service. The results of this research have identified the predominant CRDM failure modes and causes. In addition, recommendations are presented regarding specific actions that utilities can implement to mitigate CRDM aging. An evaluation has also been made of certain practices and tooling which have enabled some utilities to reduce ALARA exposures received from routine CRDM replacement and rebuilding activities

  11. Pedicle screw anchorage of carbon fiber-reinforced PEEK screws under cyclic loading.

    Science.gov (United States)

    Lindtner, Richard A; Schmid, Rene; Nydegger, Thomas; Konschake, Marko; Schmoelz, Werner

    2018-03-01

    Pedicle screw loosening is a common and significant complication after posterior spinal instrumentation, particularly in osteoporosis. Radiolucent carbon fiber-reinforced polyetheretherketone (CF/PEEK) pedicle screws have been developed recently to overcome drawbacks of conventional metallic screws, such as metal-induced imaging artifacts and interference with postoperative radiotherapy. Beyond radiolucency, CF/PEEK may also be advantageous over standard titanium in terms of pedicle screw loosening due to its unique material properties. However, screw anchorage and loosening of CF/PEEK pedicle screws have not been evaluated yet. The aim of this biomechanical study therefore was to evaluate whether the use of this alternative nonmetallic pedicle screw material affects screw loosening. The hypotheses tested were that (1) nonmetallic CF/PEEK pedicle screws resist an equal or higher number of load cycles until loosening than standard titanium screws and that (2) PMMA cement augmentation further increases the number of load cycles until loosening of CF/PEEK screws. In the first part of the study, left and right pedicles of ten cadaveric lumbar vertebrae (BMD 70.8 mg/cm 3  ± 14.5) were randomly instrumented with either CF/PEEK or standard titanium pedicle screws. In the second part, left and right pedicles of ten vertebrae (BMD 56.3 mg/cm 3  ± 15.8) were randomly instrumented with either PMMA-augmented or nonaugmented CF/PEEK pedicle screws. Each pedicle screw was subjected to cyclic cranio-caudal loading (initial load ranging from - 50 N to + 50 N) with stepwise increasing compressive loads (5 N every 100 cycles) until loosening or a maximum of 10,000 cycles. Angular screw motion ("screw toggling") within the vertebra was measured with a 3D motion analysis system every 100 cycles and by stress fluoroscopy every 500 cycles. The nonmetallic CF/PEEK pedicle screws resisted a similar number of load cycles until loosening as the contralateral standard

  12. Clinical and biomechanical researches of polyetheretherketone (PEEK) rods for semi-rigid lumbar fusion: a systematic review.

    Science.gov (United States)

    Li, Chan; Liu, Lei; Shi, Jian-Yong; Yan, Kai-Zhong; Shen, Wei-Zhong; Yang, Zhen-Rong

    2018-04-01

    Lumbar spinal fusion using rigid rods is a common surgical technique. However, adjacent segment disease and other adverse effects can occur. Dynamic stabilization devices preserve physiologic motion and reduce painful stress but have a high rate of construct failure and reoperation. Polyetheretherketone (PEEK) rods for semi-rigid fusions have a similar stiffness and adequate stabilization power compared with titanium rods, but with improved load sharing and reduced mechanical failure. The purpose of this paper is to review and evaluate the clinical and biomechanical performance of PEEK rods. A systematic review of clinical and biomechanical studies was conducted. A literature search using the PubMed, EMBASE, and Cochrane Library databases identified studies that met the eligibility criteria. Eight clinical studies and 15 biomechanical studies were included in this systematic review. The visual analog scale and the Oswestry disability index improved significantly in most studies, with satisfactory fusion rates. The occurrence of adjacent segment disease was low. In biomechanical studies, PEEK rods demonstrated a superior load-sharing distribution, a larger adjacent segment range of motion, and reduced stress at the rod-screw/screw-bone interfaces compared with titanium rods. The PEEK rod construct was simple to assemble and had a reliable in vivo performance compared with dynamic devices. The quality of clinical studies was low with confounding results, although results from mechanical studies were encouraging. There is no evidence strong enough to confirm better outcomes with PEEK rods than titanium rods. More studies with better protocols, a larger sample size, and a longer follow-up time are needed.

  13. Biomechanical comparison of force levels in spinal instrumentation using monoaxial versus multi degree of freedom postloading pedicle screws.

    Science.gov (United States)

    Wang, Xiaoyu; Aubin, Carl-Eric; Crandall, Dennis; Labelle, Hubert

    2011-01-15

    biomechanical analysis and simulations of correction mechanisms and force levels during scoliosis instrumentation using two types of pedicle screws and primary correction maneuvers. to biomechanically analyze implant-vertebra and inter-vertebral forces during scoliosis correction, to address the hypothesis that multi degree of freedom (MDOF) postloading screws with a direct incremental segmental translation (DIST) correction technique significantly reduce the loads as compared with monoaxial (MA) tulip-top design screws with a rod derotation technique (RDT). MA screw is widely used for spinal instrumentation. The MDOF screw was introduced as a refinement of the correction philosophy based on multiaxial screws. The kinematics of the MDOF construct is fundamentally different and offers more degrees of freedom than that of the MA construct; however, a systematic comparison of their biomechanics has not been done so far. a biomechanical model was developed to simulate the instrumentation of six scoliotic patients, first with the MDOF screws and DIST. Then, the instrumentation with MA screws and RDT was simulated using the same cases. Thirty more simulations were done to study the force-level sensitivity to small implant placement variation. there was a small average difference of 7°, 5°, and 4° between the two simulated systems for the computed main thoracic Cobb angle, kyphosis, and apical axial rotation, respectively. On average, the mean, standard deviation (SD), and maximum values of the implant-vertebra forces for MDOF screws were 56%, 59%, and 59%, respectively, lower than those for the MA screws, while the intervertebral forces for the MDOF screws were 31%, 37%, and 36% lower, respectively. Under the same set of random small implant placement changes, the mean, SD, and maximum values of implant-vertebra force magnitude changes for MDOF screws were 93%, 92%, and 95%, respectively, lower than those for MA screws. with MDOF screws and DIST, it is possible for

  14. Method of inserting fuel rod

    International Nuclear Information System (INIS)

    Kamimoto, Shuji; Imoo, Makoto; Tsuchida, Kenji.

    1991-01-01

    The present invention concerns a method of inserting a fuel rod upon automatic assembling, automatic dismantling and reassembling of a fuel assembly in a light water moderated reactor, as well as a device and components used therefor. That is, a fuel rod is inserted reliably to an aimed point of insertion by surrounding the periphery of the fuel rod to be inserted with guide rods, and thereby suppressing the movement of the fuel rod during insertion. Alternatively, a fuel rod is inserted reliably to a point of insertion by inserting guide rods at the periphery of the point of insertion for the fuel rod to be inserted thereby surrounding the point of insertion with the guide rods or fuel rods. By utilizing fuel rods already present in the fuel assembly as the guide rods described above, the fuel rod can be inserted reliably to the point of insertion with no additional devices. Dummy fuel rods are previously inserted in a fuel assembly which are then utilized as the above-mentioned guide rods to accurately insert the fuel rod to the point of insertion. (I.S.)

  15. Cost-Utility Analysis of Pedicle Screw Removal After Successful Posterior Instrumented Fusion in Thoracolumbar Burst Fractures.

    Science.gov (United States)

    Lee, Han-Dong; Jeon, Chang-Hoon; Chung, Nam-Su; Seo, Young-Wook

    2017-08-01

    A cost-utility analysis (CUA). The aim of this study was to determine the cost-effectiveness of pedicle screw removal after posterior fusion in thoracolumbar burst fractures. Pedicle screw instrumentation is a standard fixation method for unstable thoracolumbar burst fracture. However, removal of the pedicle screw after successful fusion remains controversial because the clinical benefits remain unclear. CUA can help clinicians make appropriate decisions about optimal health care for pedicle screw removal after successful fusion in thoracolumbar burst fractures. We conducted a single-center, retrospective, longitudinal matched-cohort study of prospectively collected outcomes. In total, 88 consecutive patients who had undergone pedicle screw instrumentation for thoracolumbar burst fracture with successful fusion confirmed by computed tomography (CT) were used in this study. In total, 45 patients wanted to undergo implant removal surgery (R group), and 43 decided not to remove the implant (NR group). A CUA was conducted from the health care perspective. The direct costs of health care were obtained from the medical bill of each patient. Changes in health-related quality of life (HRQoL) scores, validated by Short Form 6D, were used to calculate quality-adjusted life-years (QALYs). Total costs and gained QALY were calculated at 1 year (1 year) and 2 years (2 years) compared with baseline. Results are expressed as an incremental cost-effectiveness ratio (ICER). Different discount rates (0%, 3%, and 5%) were applied to both cost and QALY for sensitivity analysis. Baseline patient variables were similar between the two groups (all P > 0.05). The additional benefits of implant removal (0.201 QALY at 2 years) were achieved with additional costs ($2541 at 2 years), equating to an ICER of $12,641/QALY. On the basis of the different discount rates, the robustness of our study's results was also determined. Implant removal after successful fusion in a thoracolumbar burst

  16. In vitro validation of a novel mechanical model for testing the anchorage capacity of pedicle screws using physiological load application.

    Science.gov (United States)

    Liebsch, Christian; Zimmermann, Julia; Graf, Nicolas; Schilling, Christoph; Wilke, Hans-Joachim; Kienle, Annette

    2018-01-01

    Biomechanical in vitro tests analysing screw loosening often include high standard deviations caused by high variabilities in bone mineral density and pedicle geometry, whereas standardized mechanical models made of PU foam often do not integrate anatomical or physiological boundary conditions. The purpose of this study was to develop a most realistic mechanical model for the standardized and reproducible testing of pedicle screws regarding the resistance against screw loosening and the holding force as well as to validate this model by in vitro experiments. The novel mechanical testing model represents all anatomical structures of a human vertebra and is consisting of PU foam to simulate cancellous bone, as well as a novel pedicle model made of short carbon fibre filled epoxy. Six monoaxial cannulated pedicle screws (Ø6.5 × 45mm) were tested using the mechanical testing model as well as human vertebra specimens by applying complex physiological cyclic loading (shear, tension, and bending; 5Hz testing frequency; sinusoidal pulsating forces) in a dynamic materials testing machine with stepwise increasing load after each 50.000 cycles (100.0N shear force + 20.0N per step, 51.0N tension force + 10.2N per step, 4.2Nm bending moment + 0.8Nm per step) until screw loosening was detected. The pedicle screw head was fixed on a firmly clamped rod while the load was applied in the vertebral body. For the in vitro experiments, six human lumbar vertebrae (L1-3, BMD 75.4 ± 4.0mg/cc HA, pedicle width 9.8 ± 0.6mm) were tested after implanting pedicle screws under X-ray control. Relative motions of pedicle screw, specimen fixture, and rod fixture were detected using an optical motion tracking system. Translational motions of the mechanical testing model experiments in the point of load introduction (0.9-2.2mm at 240N shear force) were reproducible within the variation range of the in vitro experiments (0.6-3.5mm at 240N shear force). Screw loosening occurred continuously in

  17. Fuel rod puncturing and fission gas monitoring system examination techniques

    International Nuclear Information System (INIS)

    Song, Woong Sup

    1999-02-01

    Fission gas products accumulated in irradiated fuel rod is 1-2 cm 3 in CANDU and 40-50 cm 3 in PWR fuel rod. Fuel rod puncturing and fission gas monitoring system can be used for both CANDU and PWR fuel rod. This system comprises puncturing device located at in cell part and monitoring device located at out cell part. The system has computerized 9 modes and can calculate both void volume and mass volume only single puncturing. This report describes techniques and procedure for operating fuel rod puncturing and gas monitoring system which can be play an important role in successful operation of the devices. Results obtained from the analysis can give more influence over design for fuel rods. (Author). 6 refs., 9 figs

  18. Control rods

    International Nuclear Information System (INIS)

    Maruyama, Hiromi.

    1984-01-01

    Purpose: To realize effective utilization, cost reduction and weight reduction in neutron absorbing materials. Constitution: Residual amount of neutron absorbing material is averaged between the top end region and other regions of a control rod upon reaching to the control rod working life, by using a single kind of neutron absorbing material and increasing the amount of the neutron absorber material at the top end region of the control rod as compared with that in the other regions. Further, in a case of a control rod having control rod blades such as in a cross-like control rod, the amount of the neutron absorbing material is decreased in the middle portion than in the both end portions of the control rod blade along the transversal direction of the rod, so that the residual amount of the neutron absorbing material is balanced between the central region and both end regions upon reaching the working life of the control rod. (Yoshihara, H.)

  19. Seismic analysis of hydraulic control rod driving system

    International Nuclear Information System (INIS)

    Zheng, Yanhua; Bo, Hanliang; Dong, Duo

    2002-01-01

    A simplified mathematical model was developed for the Hydraulic Control Rod Driving System (HCRDS) of a 200 MW nuclear heating reactor, which incorporated the design of its chamfer-hole step cylinder, to analyze its seismic response characteristics. The control rod motion was analyzed for different sine-wave vibration loadings on platform vibrator. The vibration frequency domain and the minimum acceleration amplitude of the control rod needed to cause the control rod to step to its next setting were compared with the design acceleration amplitude spectrum. The system design was found to be safety within the calculated limits. The safety margin increased with increasing frequency. (author)

  20. Managing the aging of BWR control rod drive systems

    International Nuclear Information System (INIS)

    Greene, R.H.; Farmer, W.S.

    1992-01-01

    This Phase I Nuclear Plant Aging Research (NPAR) study examines the aging phenomena associated with BWR control and rod drive mechanisms (CRDMs) and assesses the merits of various methods of ''imaging'' this aging. Information for this study was acquired from (1) the results of a special CRDM aging questionnaire distributed to each US BWR utility, (2) a first-of-its-kind workshop held to discuss CRDM aging and maintenance concerns, (3) an analysis of the Nuclear Plant Reliability Data System (NPRDS) failure cases attributed to the control rod drive (CRD) system, and (4) personal information exchange with nuclear industry CRDM maintenance experts. The report documenting the findings of this research, NUREG-5699, will be published this year. Nearly 23% of the NPRDS CRD system component failure reports were attributed to the CRDM. The CRDM components most often requiring replacement due to aging are the Graphitar seals. The predominant causes of aging for these seals are mechanical wear and thermal embrittlement. More than 59% of the NPRDS CRD system failure reports were attributed to components that comprise the hydraulic control unit (HCU). The predominant HCU components experiencing the effects of service wear and aging are value seals, discs, seats, stems, packing, and diaphragms

  1. Key developments of a rod control system - 15101

    International Nuclear Information System (INIS)

    Pouillot, M.; Jegou, H.; Duthou, A.

    2015-01-01

    The aim of the Rod Control System is to carry out the insertion and withdrawal of control rod clusters to provide the power required by the grid (G-mode control), to control the temperature of the reactor, or to provide negative reactivity margin when the reactor is shut down. The rod control system is not classified important for safety, but its correct operation is essential for the availability of the reactor, as the spurious drop of a single cluster usually results in a reactor trip. Rolls-Royce has been designing, manufacturing and providing rod control systems since 1977, in France, China, Belgium, Korea, and South Africa, as an original manufacturer and for modernization projects. All the corresponding nuclear units share the following features, key points for the system design: -) The power source is a three-phased 260 Vac with neutral, provided by zigzag-coupled alternators; -) The Control Rod Drive Mechanisms (CRDM) are 'three-coil type': Stationary Gripper (SG), Movable Gripper (MG) and Lift Coil (LC); -) Rod clusters are arranged in banks and sub-banks, the bank being composed of one or two sub-banks and a sub-bank is a set of 4 clusters moved simultaneously, the central cluster being an exception; and -) Most of those reactors are operated in G-mode (load following). (authors)

  2. Removal torque of nail interlocking screws is related to screw proximity to the fracture and screw breakage.

    Science.gov (United States)

    White, Alexander A; Kubacki, Meghan R; Samona, Jason; Telehowski, Paul; Atkinson, Patrick J

    2016-06-01

    Studies have shown that titanium implants can be challenging to explant due to the material's excellent biocompatibility and resulting osseointegration. Clinically, titanium alloy nail interlocking screws may require removal to dynamize a construct or revise the nail due to nonunion, infection, pain, or periprosthetic fracture. This study was designed to determine what variables influence the removal torque for titanium alloy interlocking screws. An intramedullary nail with four interlocking screws was used to stabilize a 1-cm segmental femoral defect in a canine model for 16 weeks. The animals were observed to be active following a several-day recovery after surgery. In six animals, the femora and implanted nail/screws were first tested to failure in torsion to simulate periprosthetic fracture of an implant after which the screws were then removed. In four additional animals, the screws were removed without mechanical testing. Both intraoperative insertional and extraction torques were recorded for all screws. Mechanical testing to failure broke 10/24 screws. On average, the intact screws required 70% of the insertional torque during removal while broken screws only required 16% of the insertional torque (p torque than the outboard distal screw (p torque was ∼80°. The peak axial load did not significantly correlate with the torque required to remove the screws. On average, the removal torque was lower than at the time of insertion, and less torque was required to remove broken screws and screws remote to the fracture. However, broken screws will require additional time to retrieve the remaining screw fragment. This study suggests that broken screws and screws in prematurely active patients will require less torque to remove. © IMechE 2016.

  3. Probing and Tapping: Are We Inserting Pedicle Screws Correctly?

    Science.gov (United States)

    Prasad, Vishal; Mesfin, Addisu; Lee, Robert; Reigrut, Julie; Schmidt, John

    2016-11-01

    Although there are a significant number of research publications on the topic of bone morphology and the strength of bone, the clinical significance of a failed pedicle screw is often revision surgery and the potential for further postoperative complications; especially in elderly patients with osteoporotic bone. The purpose of this report is to quantify the mechanical strength of the foam-screw interface by assessing probe/pilot hole diameter and tap sizes using statistically relevant sample sizes under highly controlled test conditions. The study consisted of two experiments and used up to three different densities of reference-grade polyurethane foam (ASTM 1839), including 0.16, 0.24, and 0.32 g/cm 3 . All screws and rods were provided by K2M Inc. and screws were inserted to a depth of 25 mm. A series of pilot holes, 1.5, 2.2, 2.7, 3.2, 3.7, 4.2, 5.0, and 6.0 mm in diameter were drilled through the entire depth of the material. A 6.5 × 45-mm pedicle screw was inserted and axially pulled from the material (n = 720). A 3.0-mm pilot hole was drilled and tapped with: no tap, 3.5-, 4.5-, 5.5-, and 6.5-mm taps. A 6.5 × 45-mm pedicle screw was inserted and axially pulled from the material (n = 300). The size of the probe/pilot hole had a nonlinear, parabolic effect on pullout strength. This shape suggests an optimum-sized probe hole for a given size pedicle screw. Too large or too small of a probe hole causes a rapid falloff in pullout strength. The tap data demonstrated that not tapping and undertapping by two or three sizes did not significantly alter the pullout strength of the screws. The data showed an exponential falloff of pullout strength when as tap size increased to the diameter of the screw. In the current study, the data show that an ideal pilot hole size half the diameter of the screw is a starting point. Also, that if tapping was necessary, to use a tap two sizes smaller than the screw being implanted. A similar optimum pilot hole or tap size may be

  4. Review of FFTF and CRBRP control rod systems designs

    International Nuclear Information System (INIS)

    Pitterle, T.A.; Lagally, H.O.

    1977-01-01

    The evolution of the primary control rod system design for FFTF and CRBR, beginning with the initial choice of the basic concepts, is described. The significant component and systems tests are reviewed together with the test results which referenced the development of the CRBR primary control rod system design. Modifications to the concepts and detail designs of the FFTF control rod system were required principally to satisfy the requirements of CRBR, and at the same time incorporating design refinements shown desirable by the tests

  5. Ball Screw Actuator Including a Compliant Ball Screw Stop

    Science.gov (United States)

    Wingett, Paul T. (Inventor); Hanlon, Casey (Inventor)

    2017-01-01

    An actuator includes a ball nut, a ball screw, and a ball screw stop. The ball nut is adapted to receive an input torque and in response rotates and supplies a drive force. The ball screw extends through the ball nut and has a first end and a second end. The ball screw receives the drive force from the ball nut and in response selectively translates between a retract position and a extend position. The ball screw stop is mounted on the ball screw proximate the first end to translate therewith. The ball screw stop engages the ball nut when the ball screw is in the extend position, translates, with compliance, a predetermined distance toward the first end upon engaging the ball nut, and prevents further rotation of the ball screw upon translating the predetermined distance.

  6. Clinical effects of posterior pedicle screw fixation on spinal deformity in growing period: a report of 360 cases

    Directory of Open Access Journals (Sweden)

    Zheng-lei WANG

    2011-08-01

    Full Text Available Objective To observe the effect of a new kind of pedicle screw frame system with sliding terminus and locked middle segment on spinal deformity in growing period.Methods Three hundred and sixty patients in growing period were involved in the present study,and among them 82 were suffering from congenital scoliosis,218 idiopathic scoliosis and 60 kyphosis.All the patients were treated with the pedicle screw frame system with sliding terminus and locked middle segment.The treatment effects and postoperative complications were observed,and the Cobb angle before and after the operation was compared.Results The Cobb angle of 300 scoliosis patients was corrected from 53°±3° to 8°±2°,and the Cobb angle of 60 kyphosis patients was corrected from 60°±2° to 25°±3°,and the corrective effect was satisfactory.The correction rate of patients with Cobb angle ≤50° was 80%.Two hundred and ten patients were followed-up for 1 to 6 years,and the longitudinal growth of spine was 1.5-4.0cm.No severe complication,such as screw fracture,rod fracture or nerve injury,occurred.Conclusion The pedicle screw frame system with sliding terminus had a favorable three-dimensional correction effect,and the spine growth would not be restricted,and there was no stiffness,vertebral rotation,or distortion of shaft after operation.

  7. Drive transmission system between a driving organ and a receiver organ

    International Nuclear Information System (INIS)

    Guillot, J.F.

    1985-01-01

    The present invention applies to the control rods of a water cooled nuclear reactor. The drive transmission system is disposed on the internal kinematic chain, between the control rod which is the receiver organ, and the driving organ. The control rod translation is obtained from a motion of rotation transformed in a motion of translation by means of a screw-nut system. The present invention prevents from control rod ejection in case of depressurization of the vessel containing the control rod drives or in case of reactor upsetting when it is embarked [fr

  8. Rod drive and latching mechanism

    International Nuclear Information System (INIS)

    Veronesi, L.; Sherwood, D.G.

    1982-01-01

    Hydraulic drive and latching mechanisms for driving reactivity control mechanisms in nuclear reactors are described. Preferably, the pressurized reactor coolant is utilized to raise the drive rod into contact with and to pivot the latching mechanism so as to allow the drive rod to pass the latching mechanism. The pressure in the housing may then be equalized which allows the drive rod to move downwardly into contact with the latching mechanism but to hold the shaft in a raised position with respect to the reactor core. Once again, the reactor coolant pressure may be utilized to raise the drive rod and thus pivot the latching mechanism so that the drive rod passes above the latching mechanism. Again, the mechanism pressure can be equalized which allows the drive rod to fall and pass by the latching mechanism so that the drive rod approaches the reactor core. (author)

  9. Fuel rod attachment system

    International Nuclear Information System (INIS)

    Christiansen, D.W.

    1982-01-01

    A reusable system for removably attaching a nuclear reactor fuel rod to a support member. A locking cap is secured to the fuel rod and a locking strip is fastened to the support member or vice versa. The locking cap has two opposing fingers and shaped to form a socket having a body portion. The locking strip has an extension shaped to rigidly attach to the socket's body portion. The locking cap's fingers are resiliently deflectable. For attachment, the locking cap is longitudinally pushed onto the locking strip causing the extension to temporarily deflect open the fingers to engage the socket's body portion. For removal, the process is reversed. In an alternative embodiment, the cap is rigid and the strip is transversely resiliently compressible. (author)

  10. BWR control rod drive scram pilot valve monitoring program

    International Nuclear Information System (INIS)

    Soden, R.A.; Kelly, V.

    1986-01-01

    The control rod drive system in a Boiling Water Reactor is the most important safety system in the power plant. All components of the system can be verified except the solenoid operated, scram pilot valves without scramming a rod. The pilot valve mechanical works is the weak link to the control rod drive system. These pilot valves control the hydraulic system which applies pressure to the insert side of the control rod piston and vents the withdraw side of the piston causing the rods to insert during a scram. The only verification that the valve is operating properly is to scram the rod. The concern for this portion of the system is demonstrated by the high number of redundant components and complete periodic testing of the electrical circuits. The pilot valve can become hung-up through wear, fracture of internal components, mechanical binding, foreign material or chemicals left in the valve during maintenance, etc. If the valve becomes hung-up the electrical tests performed will not indicate this condition and scramming the rod is in jeopardy. Only an attempt to scram a rod will indicate the hung-up valve. While this condition exists the rod is considered inoperative. This paper describes a system developed at a nuclear power plant that monitors the pilot valves on the control rod drive system. This system utilizes pattern recognition to assure proper internal workings of the scram pilot valves to plant operators. The system is totally automatic such that each time the valve is operated on a half scram, a printout is available to the operator along with light indication that each of the 370 valves (on one unit of a BWR) is operating properly. With this monitoring system installed, all components of the control rod drive system including the solenoid pilot valves can be verified as operational without scramming any rods

  11. Conceptual Design on Primary Control Rod Drive Mechanism of a Prototype Gen-IV SFR

    International Nuclear Information System (INIS)

    Lee, Jae Han; Koo, Gyeong Hoi

    2013-01-01

    This paper describes the key concept of the drive mechanism, and suggests a required motor power and reducer gears to meet the functional design requirements, and a seismic response analysis of CRDM housing is performed to check its structural integrity. An AC servo motor is selected as a CRA driving power because it uses permanent magnets and is brushless type while DC motor needs a brush and a coil rotates. The control shim motor size is constrained by a housing diameter of 250mm. The driving system has several design requirements. To calculate the motor power, the drive shaft torque is needed. One part of the drive shaft has a lead screw, driving by a ball-nut. The ball screw driver torque (Tr) is calculated by some equations as follow; A servo motor with a nominal power of 100W, a nominal torque of 0.32 N-m (max. 0.48N-m) is selected considering a safety margin. Its diameter is about 50mm. The fast drive-in motor needs a strong power to insert enforcedly the stuck CRA into core within a required time. The motor sizes are calculated by the same procedure. The diameters are in the range of 80mm to 110mm by the insertion time (10 ∼ 24 seconds). The prototype Gen-IV SFR (sodium-cooled Fast Reactor) is of 150MWe capacity. The reactor has six primary control rod assemblies(CRAs). The primary control rod is used for power control, burn-up compensation and reactor shutdown in response to demands from the plant control or protection systems. The control rod drive mechanism (CRDM) consists of the drive motor assembly, the driveline, and its housing. The driveline consists of three concentric members of a drive shaft, a tension tube, and a position indicator rod, and it connects the drive motor assembly to the CRA. Main issue is that these many driving parts shall be enclosed within a limited housing diameter because the available pitch of CRDMs is limited by 300mm

  12. Conceptual Design on Primary Control Rod Drive Mechanism of a Prototype Gen-IV SFR

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Jae Han; Koo, Gyeong Hoi [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of)

    2013-10-15

    This paper describes the key concept of the drive mechanism, and suggests a required motor power and reducer gears to meet the functional design requirements, and a seismic response analysis of CRDM housing is performed to check its structural integrity. An AC servo motor is selected as a CRA driving power because it uses permanent magnets and is brushless type while DC motor needs a brush and a coil rotates. The control shim motor size is constrained by a housing diameter of 250mm. The driving system has several design requirements. To calculate the motor power, the drive shaft torque is needed. One part of the drive shaft has a lead screw, driving by a ball-nut. The ball screw driver torque (Tr) is calculated by some equations as follow; A servo motor with a nominal power of 100W, a nominal torque of 0.32 N-m (max. 0.48N-m) is selected considering a safety margin. Its diameter is about 50mm. The fast drive-in motor needs a strong power to insert enforcedly the stuck CRA into core within a required time. The motor sizes are calculated by the same procedure. The diameters are in the range of 80mm to 110mm by the insertion time (10 ∼ 24 seconds). The prototype Gen-IV SFR (sodium-cooled Fast Reactor) is of 150MWe capacity. The reactor has six primary control rod assemblies(CRAs). The primary control rod is used for power control, burn-up compensation and reactor shutdown in response to demands from the plant control or protection systems. The control rod drive mechanism (CRDM) consists of the drive motor assembly, the driveline, and its housing. The driveline consists of three concentric members of a drive shaft, a tension tube, and a position indicator rod, and it connects the drive motor assembly to the CRA. Main issue is that these many driving parts shall be enclosed within a limited housing diameter because the available pitch of CRDMs is limited by 300mm.

  13. "Push-Through" Rod Passage Technique for the Improvement of Lumbar Lordosis and Sagittal Balance in Minimally Invasive Adult Degenerative Scoliosis Surgery.

    Science.gov (United States)

    Haque, Raqeeb M; Uddin, Omar M; Ahmed, Yousef; El Ahmadieh, Tarek Y; Hashmi, Sohaib Z; Shah, Amir; Fessler, Richard G

    2016-10-01

    Traditional open surgical techniques for correction of adult degenerative scoliosis (ADS) are often associated with increased blood loss, postoperative pain, and complications. Minimally invasive (MIS) techniques have been utilized to address these issues; however, concerns regarding improving certain alignment parameters have been raised. A new "push-through" technique for MIS correction of ADS has been developed wherein a rod is bent before its placement into the screw heads and then contoured further to yield improved correction of radiographic parameters. Preoperative and postoperative radiographic measurements of 3 patients who underwent MIS correction of scoliosis using the "push-through" technique were compared with 22 prior patients who had received traditional MIS correction. All patients received staged correction of scoliosis. The first stage involved insertion of lateral lumbar interbodies. Standing x-rays were then evaluated for overall global balance. The second stage involved appropriate MIS facetectomies, facet fusions, posterior transforaminal interbodies at lower lumbar segments, and finally the placement of rods.TECHNIQUE OVERVIEW:: (1) A long rod composed of titanium is bent with a mild lordosis and passed through the extensions of the screw heads cephalad to caudad. (2) The rod is passed fully through the incision so it extrudes from the caudal end of the construct. At this point, further lordosis is bent into the rods. (3) The rod is then pulled back into the appropriate position. (4) The unnecessary cephalad rod is then cut to appropriate length with a circular saw. (5) Rod reducers are then sequentially lowered and tightened to achieve the desired correction. Mean age for all patients was 66.02 years. Preoperative coronal Cobb, sagittal vertical axis (SVA), and pelvic incidence (PI) were similar in all patients, whereas lumbar lordosis (LL) was smaller (15.27 vs. 29.85 degrees, P=0.00389) and pelvic tilt (PT) was larger (37.00 vs. 27

  14. Simultaneous double-rod rotation technique in posterior instrumentation surgery for correction of adolescent idiopathic scoliosis.

    Science.gov (United States)

    Ito, Manabu; Abumi, Kuniyoshi; Kotani, Yoshihisa; Takahata, Masahiko; Sudo, Hideki; Hojo, Yoshihiro; Minami, Akio

    2010-03-01

    The authors present a new posterior correction technique consisting of simultaneous double-rod rotation using 2 contoured rods and polyaxial pedicle screws with or without Nesplon tapes. The purpose of this study is to introduce the basic principles and surgical procedures of this new posterior surgery for correction of adolescent idiopathic scoliosis. Through gradual rotation of the concave-side rod by 2 rod holders, the convex-side rod simultaneously rotates with the the concave-side rod. This procedure does not involve any force pushing down the spinal column around the apex. Since this procedure consists of upward pushing and lateral translation of the spinal column with simultaneous double-rod rotation maneuvers, it is simple and can obtain thoracic kyphosis as well as favorable scoliosis correction. This technique is applicable not only to a thoracic single curve but also to double major curves in cases of adolescent idiopathic scoliosis.

  15. Removal and replacement of fuel rods in nuclear fuel assembly

    International Nuclear Information System (INIS)

    Shallenberger, J.M.; Ferlan, S.J.

    1983-01-01

    Apparatus for replacing components of a nuclear fuel assembly stored in a pit under about 10 m. of water. The fuel assembly is secured in a container which is rotatable from the upright position to an inverted position in which the bottom nozzle is upward. The bottom nozzle plate is disconnected from the control-rod thimbles by means of a cutter for severing the welds. To guide and provide lateral support for the cutter a fixture including bushings is provided, each encircling a screw fastener and sealing the region around a screw fastener to trap the chips from the severed weld. Chips adhering to the cutter are removed by a suction tube of an eductor. (author)

  16. Plasmonic-cavity model for radiating nano-rod antennas

    DEFF Research Database (Denmark)

    Peng, Liang; Mortensen, N. Asger

    2014-01-01

    In this paper, we propose the analytical solution of nano-rod antennas utilizing a cylindrical harmonics expansion. By treating the metallic nano-rods as plasmonic cavities, we derive closed-form expressions for both the internal and the radiated fields, as well as the resonant condition and the ......In this paper, we propose the analytical solution of nano-rod antennas utilizing a cylindrical harmonics expansion. By treating the metallic nano-rods as plasmonic cavities, we derive closed-form expressions for both the internal and the radiated fields, as well as the resonant condition...... and the radiation efficiency. With our theoretical model, we show that besides the plasmonic resonances, efficient radiation takes advantage of (a) rendering a large value of the rods' radius and (b) a central-fed profile, through which the radiation efficiency can reach up to 70% and even higher in a wide...... frequency band. Our theoretical expressions and conclusions are general and pave the way for engineering and further optimization of optical antenna systems and their radiation patterns....

  17. Fuel rod fixing system

    International Nuclear Information System (INIS)

    Christiansen, D.W.

    1982-01-01

    This is a reusable system for fixing a nuclear reactor fuel rod to a support. An interlock cap is fixed to the fuel rod and an interlock strip is fixed to the support. The interlock cap has two opposed fingers, which are shaped so that a base is formed with a body part. The interlock strip has an extension, which is shaped so that this is rigidly fixed to the body part of the base. The fingers of the interlock cap are elastic in bending. To fix it, the interlock cap is pushed longitudinally on to the interlock strip, which causes the extension to bend the fingers open in order to engage with the body part of the base. To remove it, the procedure is reversed. (orig.) [de

  18. Detection and mitigating rod drive control system degradation in Westinghouse PWRs

    International Nuclear Information System (INIS)

    Gunther, W.; Sullivan, K.

    1990-01-01

    A study of the effects of aging on the Westinghouse Control Rod Drive (CRD) System was performed as part of the US NRC's Nuclear Plant aging Research (NPAR) Program. For the study, the CRD system boundary includes the power and logic cabinets associated with the manual control rod movement, and the control rod mechanism itself. The aging-related degradation of the interconnecting cables and connectors and the rod position indicating system also were considered. This paper presents the results of that study pertaining to the electrical and instrumentation portions of the CRD system including ways to detect and mitigate system degradation

  19. Knowledge based system for control rod programming of BWRs

    International Nuclear Information System (INIS)

    Fukuzaki, Takaharu; Yoshida, Ken-ichi; Kobayashi, Yasuhiro

    1988-01-01

    A knowledge based system has been developed to support designers in control rod programming of BWRs. The programming searches through optimal control rod patterns to realize safe and effective burning of nuclear fuel. Knowledge of experienced designers plays the main role in minimizing the number of calculations by the core performance evaluation code. This code predicts power distibution and thermal margins of the nuclear fuel. This knowledge is transformed into 'if-then' type rules and subroutines, and is stored in a knowledge base of the knowledge based system. The system consists of working area, an inference engine and the knowledge base. The inference engine can detect those data which have to be regenerated, call those subroutine which control the user's interface and numerical computations, and store competitive sets of data in different parts of the working area. Using this system, control rod programming of a BWR plant was traced with about 500 rules and 150 subroutines. Both the generation of control rod patterns for the first calculation of the code and the modification of a control rod pattern to reflect the calculation were completed more effectively than in a conventional method. (author)

  20. Simple New Screw Insertion Technique without Extraction for Broken Pedicle Screws.

    Science.gov (United States)

    Kil, Jin-Sang; Park, Jong-Tae

    2018-05-01

    Spinal transpedicular screw fixation is widely performed. Broken pedicle screw rates range from 3%-7.1%. Several techniques have been described for extraction of broken pedicle screws. However, most of these techniques require special instruments. We describe a simple, modified technique for management of broken pedicle screws without extraction. No special instruments or drilling in an adjacent pedicle are required. We used a high-speed air drill with a round burr. With C-arm fluoroscopy guidance, the distal fragment of a broken pedicle screw was palpated using free-hand technique through the screw entry hole. A high-speed air drill with a round burr (not a diamond burr) was inserted through the hole. Drilling began slowly and continued until enough space was obtained for new screw insertion. Using this space, we performed new pedicle screw fixation medially alongside the distal fragment of the broken pedicle screw. We performed the insertion with a previously used entry hole and pathway in the pedicle. The same size pedicle screw was used. Three patients were treated with this modified technique. New screw insertion was successful in all cases after partial drilling of the distal broken pedicle screw fragment. There were no complications, such as screw loosening, dural tears, or root injury. We describe a simple, modified technique for management of broken pedicle screws without extraction. This technique is recommended in patients who require insertion of a new screw. Copyright © 2017. Published by Elsevier Inc.

  1. Undertapping of Lumbar Pedicle Screws Can Result in Tapping With a Pitch That Differs From That of the Screw, Which Decreases Screw Pullout Force.

    Science.gov (United States)

    Bohl, Daniel D; Basques, Bryce A; Golinvaux, Nicholas S; Toy, Jason O; Matheis, Erika A; Bucklen, Brandon S; Grauer, Jonathan N

    2015-06-15

    Survey of spine surgeons and biomechanical comparison of screw pullout forces. To investigate what may be a suboptimal practice regularly occurring in spine surgery. In order for a tap to function in its intended manner, the pitch of the tap should be the same as the pitch of the screw. Undertapping has been shown to increase the pullout force of pedicle screws compared with line-to-line tapping. However, given the way current commercial lumbar pedicle screw systems are designed, undertapping may result in a tap being used that has a different pitch from that of the screw (incongruent pitch). A survey asked participants questions to estimate the proportion of cases each participant performed in the prior year using various hole preparation techniques. Participant responses were interpreted in the context of manufacturing specifications of specific instrumentation systems. Screw pullout forces were compared between undertapping with incongruent pitch and undertapping with congruent pitch using 0.16 g/cm polyurethane foam block and 6.5-mm screws. Of the 3679 cases in which participants reported tapping, participants reported line-to-line tapping in 209 cases (5%), undertapping with incongruent pitch in 1156 cases (32%), and undertapping with congruent pitch in 2314 cases (63%). The mean pullout force for undertapping with incongruent pitch was 56 N (8%) less than the mean pullout force for undertapping with congruent pitch. This is equivalent to 13 lb. This study estimates that for about 1 out of every 3 surgical cases with tapping of lumbar pedicle screws in the United States, hole preparation is being performed by undertapping with incongruent pitch. This study also shows that undertapping with incongruent pitch results in a decrease in pullout force by 8% compared with undertapping with congruent pitch. Steps should be taken to correct this suboptimal practice. 3.

  2. THE USE OF NITINOL RODS IN SURGICAL TREATMENT OF DEGENERATIVE SCOLIOSIS. 2.5-YEAR FOLLOW-UP

    Directory of Open Access Journals (Sweden)

    Natalia Sergeyevna Morozova

    2016-03-01

    Full Text Available ABSTRACT Objectives: To compare the outcomes of surgical treatment with lumbar fixation using nitinol rods without fusion and with standard lumbar fixation with titanium rods and interbody fusion. Methods: Treatment results of 70 patients with degenerative lumbar scoliosis aged 40 to 82 were analyzed. In all cases pedicle screws and nitinol rods with a diameter of 5.5 mm were used. Thirty patients underwent fixation at L1-S1 and 40 patients underwent fixation at L1-L5. Spinal fusion was not performed. All patients had radiography, CT and MRI performed. The results were assessed according to the Oswestry scale, SRS 22, SF 36 and VAS. The minimum follow-up period for all patients was 2.5 years. For the control group, consisting of 72 patients, pedicle fixation with titanium rods and interbody fusion in the lumbosacral region were performed. Results: The average level of deformity correction equaled 25° (10° - 38°. The analysis of X-ray and CT-scans revealed a single patient with implant instability, two patients with bone resorption around the screws and one patient with rod fractures. Functional radiography 2.5 years after surgery showed an average mobility of the lumbar spine of 21° (15° - 30°. There were no problems at the adjacent levels. Conclusions: The use of nitinol rods in spinal deformity surgery is promising. This technology is an alternative to rigid fixation. Continued gathering of clinical data and its further evaluation is necessary.

  3. Navigation of Pedicle Screws in the Thoracic Spine with a New Electromagnetic Navigation System: A Human Cadaver Study

    Directory of Open Access Journals (Sweden)

    Patrick Hahn

    2015-01-01

    Full Text Available Introduction. Posterior stabilization of the spine is a standard procedure in spinal surgery. In addition to the standard techniques, several new techniques have been developed. The objective of this cadaveric study was to examine the accuracy of a new electromagnetic navigation system for instrumentation of pedicle screws in the spine. Material and Method. Forty-eight pedicle screws were inserted in the thoracic spine of human cadavers using EMF navigation and instruments developed especially for electromagnetic navigation. The screw position was assessed postoperatively by a CT scan. Results. The screws were classified into 3 groups: grade 1 = ideal position; grade 2 = cortical penetration <2 mm; grade 3 = cortical penetration ≥2 mm. The initial evaluation of the system showed satisfied positioning for the thoracic spine; 37 of 48 screws (77.1%, 95% confidence interval [62.7%, 88%] were classified as group 1 or 2. Discussion. The screw placement was satisfactory. The initial results show that there is room for improvement with some changes needed. The ease of use and short setup times should be pointed out. Instrumentation is achieved without restricting the operator’s mobility during navigation. Conclusion. The results indicate a good placement technique for pedicle screws. Big advantages are the easy handling of the system.

  4. Cortical bone trajectory screw fixation versus traditional pedicle screw fixation for 2-level posterior lumbar interbody fusion: comparison of surgical outcomes for 2-level degenerative lumbar spondylolisthesis.

    Science.gov (United States)

    Sakaura, Hironobu; Miwa, Toshitada; Yamashita, Tomoya; Kuroda, Yusuke; Ohwada, Tetsuo

    2018-01-01

    OBJECTIVE The cortical bone trajectory (CBT) screw technique is a new nontraditional pedicle screw (PS) insertion method. However, the biomechanical behavior of multilevel CBT screw/rod fixation remains unclear, and surgical outcomes in patients after 2-level posterior lumbar interbody fusion (PLIF) using CBT screw fixation have not been reported. Thus, the purposes of this study were to examine the clinical and radiological outcomes after 2-level PLIF using CBT screw fixation for 2-level degenerative lumbar spondylolisthesis (DS) and to compare these outcomes with those after 2-level PLIF using traditional PS fixation. METHODS The study included 22 consecutively treated patients who underwent 2-level PLIF with CBT screw fixation for 2-level DS (CBT group, mean follow-up 39 months) and a historical control group of 20 consecutively treated patients who underwent 2-level PLIF using traditional PS fixation for 2-level DS (PS group, mean follow-up 35 months). Clinical symptoms were evaluated using the Japanese Orthopaedic Association (JOA) scoring system. Bony union was assessed by dynamic plain radiographs and CT images. Surgery-related complications, including symptomatic adjacent-segment disease (ASD), were examined. RESULTS The mean operative duration and intraoperative blood loss were 192 minutes and 495 ml in the CBT group and 218 minutes and 612 ml in the PS group, respectively (p 0.05, respectively). The mean JOA score improved significantly from 12.3 points before surgery to 21.1 points (mean recovery rate 54.4%) at the latest follow-up in the CBT group and from 12.8 points before surgery to 20.4 points (mean recovery rate 51.8%) at the latest follow-up in the PS group (p > 0.05). Solid bony union was achieved at 90.9% of segments in the CBT group and 95.0% of segments in the PS group (p > 0.05). Symptomatic ASD developed in 2 patients in the CBT group (9.1%) and 4 patients in the PS group (20.0%, p > 0.05). CONCLUSIONS Two-level PLIF with CBT screw fixation

  5. Precision insertion of percutaneous sacroiliac screws using a novel augmented reality-based navigation system: a pilot study.

    Science.gov (United States)

    Wang, Huixiang; Wang, Fang; Leong, Anthony Peng Yew; Xu, Lu; Chen, Xiaojun; Wang, Qiugen

    2016-09-01

    Augmented reality (AR) enables superimposition of virtual images onto the real world. The aim of this study is to present a novel AR-based navigation system for sacroiliac screw insertion and to evaluate its feasibility and accuracy in cadaveric experiments. Six cadavers with intact pelvises were employed in our study. They were CT scanned and the pelvis and vessels were segmented into 3D models. The ideal trajectory of the sacroiliac screw was planned and represented visually as a cylinder. For the intervention, the head mounted display created a real-time AR environment by superimposing the virtual 3D models onto the surgeon's field of view. The screws were drilled into the pelvis as guided by the trajectory represented by the cylinder. Following the intervention, a repeat CT scan was performed to evaluate the accuracy of the system, by assessing the screw positions and the deviations between the planned trajectories and inserted screws. Post-operative CT images showed that all 12 screws were correctly placed with no perforation. The mean deviation between the planned trajectories and the inserted screws was 2.7 ± 1.2 mm at the bony entry point, 3.7 ± 1.1 mm at the screw tip, and the mean angular deviation between the two trajectories was 2.9° ± 1.1°. The mean deviation at the nerve root tunnels region on the sagittal plane was 3.6 ± 1.0 mm. This study suggests an intuitive approach for guiding screw placement by way of AR-based navigation. This approach was feasible and accurate. It may serve as a valuable tool for assisting percutaneous sacroiliac screw insertion in live surgery.

  6. Stress and stability of plate-screw fixation and screw fixation in the treatment of Schatzker type IV medial tibial plateau fracture: a comparative finite element study.

    Science.gov (United States)

    Huang, Xiaowei; Zhi, Zhongzheng; Yu, Baoqing; Chen, Fancheng

    2015-11-25

    The purpose of this study is to compare the stress and stability of plate-screw fixation and screw fixation in the treatment of Schatzker type IV medial tibial plateau fracture. A three-dimensional (3D) finite element model of the medial tibial plateau fracture (Schatzker type IV fracture) was created. An axial force of 2500 N with a distribution of 60% to the medial compartment was applied to simulate the axial compressive load on an adult knee during single-limb stance. The equivalent von Mises stress, displacement of the model relative to the distal tibia, and displacement of the implants were used as the output measures. The mean stress value of the plate-screw fixation system was 18.78 MPa, which was significantly (P stress value of the triangular fragment in the plate-screw fixation system model was 42.04 MPa, which was higher than that in the screw fixation model (24.18 MPa). But the mean stress of the triangular fractured fragment in the screw fixation model was significantly higher in terms of equivalent von Mises stress (EVMS), x-axis, and z-axis (P < 0.001). This study demonstrated that the load transmission mechanism between plate-screw fixation system and screw fixation system was different and the stability provided by the plate-screw fixation system was superior to the screw fixation system.

  7. REACTOR CONTROL ROD OPERATING SYSTEM

    Science.gov (United States)

    Miller, G.

    1961-12-12

    A nuclear reactor control rod mechanism is designed which mechanically moves the control rods into and out of the core under normal conditions but rapidly forces the control rods into the core by catapultic action in the event of an emergency. (AEC)

  8. Dual-worm screw compressors; Compresseurs bi-vis

    Energy Technology Data Exchange (ETDEWEB)

    Baleydier, J P [Bitzer France, 69 - Lyon (France)

    1998-12-31

    Low power worm-screw moto-compressors are used in any king of refrigerating machineries and more and more in air conditioning systems. This paper presents the principle of dual-screw moto-compressors: worm-screw technology, role of oil (lubrication, tightness, cooling), compression, internal pressure, power reduction, lubrication, economizer, operation, model selection and accessories. (J.S.)

  9. Dual-worm screw compressors; Compresseurs bi-vis

    Energy Technology Data Exchange (ETDEWEB)

    Baleydier, J.P. [Bitzer France, 69 - Lyon (France)

    1997-12-31

    Low power worm-screw moto-compressors are used in any king of refrigerating machineries and more and more in air conditioning systems. This paper presents the principle of dual-screw moto-compressors: worm-screw technology, role of oil (lubrication, tightness, cooling), compression, internal pressure, power reduction, lubrication, economizer, operation, model selection and accessories. (J.S.)

  10. Assessment of Different Metal Screw Joint Parameters by Using Multiple Criteria Analysis Methods

    Directory of Open Access Journals (Sweden)

    Audrius Čereška

    2018-05-01

    Full Text Available This study compares screw joints made of different materials, including screws of different diameters. For that purpose, 8, 10, 12, 14, 16 mm diameter steel screws and various parts made of aluminum (Al, steel (Stl, bronze (Brz, cast iron (CI, copper (Cu and brass (Br are considered. Multiple criteria decision making (MCDM methods such as evaluation based on distance from average solution (EDAS, simple additive weighting (SAW, technique for order of preference by similarity to ideal solution (TOPSIS and complex proportional assessment (COPRAS are utilized to assess reliability of screw joints also considering cost issues. The entropy, criterion impact loss (CILOS and integrated determination of objective criteria weights (IDOCRIW methods are utilized to assess weights of decision criteria and find the best design alternative. Numerical results confirm the validity of the proposed approach.

  11. Degradation behaviour of LAE442-based plate–screw-systems in an in vitro bone model

    International Nuclear Information System (INIS)

    Wolters, Leonie; Besdo, Silke; Angrisani, Nina; Wriggers, Peter; Hering, Britta; Seitz, Jan-Marten; Reifenrath, Janin

    2015-01-01

    The use of absorbable implant materials for fixation after bone fracture helps to avoid a second surgery for implant removal and the risks and costs involved. Magnesium (Mg) is well known as a potential metallic material for degradable implants. The aim of the present in vitro study was to evaluate if degradable LAE442-based magnesium plate–screw-systems are suitable candidates for osteosynthesis implants in load-bearing bones. The corrosion behaviour was tested concerning the influence of different surface treatments, coatings and screw torques. Steel plates and screws of the same size served as control. Plates without special treatment screwed on up to a specified torque of 15 cNm or 7 cNm, NaOH treated plates (15 cNm), magnesium fluoride coated plates (15 cNm) and steel plates as control (15 cNm) were examined in pH-buffered, temperature-controlled SBF solution for two weeks. The experimental results indicate that the LAE442 plates and screws coated with magnesium fluoride revealed a lower hydrogen evolution in SBF solution as well as a lower weight loss and volume decrease in μ-computed tomography (μCT). The nanoindentation and SEM/EDX measurements at several plate areas showed no significant differences. Summarized, the different screw torques did not affect the corrosion behaviour differently. Also the NaOH treatment seemed to have no essential influence on the degradation kinetics. The plates coated with magnesium fluoride showed a decreased corrosion rate. Hence, it is recommended to consider this coating for the next in vivo study. - Highlights: • Mg-based plate screw systems were examined in an in vitro corrosion setup. • Different screw torques did not affect the corrosion behaviour. • Pretreatment with NaOH showed no increase in corrosion resistance. • Fluoride coating slowed down the corrosion rate of plates. • Fluoride coating might be an alternative for decrease of corrosion rate in vivo

  12. Degradation behaviour of LAE442-based plate–screw-systems in an in vitro bone model

    Energy Technology Data Exchange (ETDEWEB)

    Wolters, Leonie [Small Animal Clinic, University of Veterinary Medicine Hannover, Foundation, Bünteweg 9, 30559 Hannover (Germany); Besdo, Silke [Institute of Continuum Mechanics, Leibniz Universität Hannover, Appelstraße 11, 30167 Hannover (Germany); Angrisani, Nina [Small Animal Clinic, University of Veterinary Medicine Hannover, Foundation, Bünteweg 9, 30559 Hannover (Germany); Wriggers, Peter [Institute of Continuum Mechanics, Leibniz Universität Hannover, Appelstraße 11, 30167 Hannover (Germany); Hering, Britta [Institute of Production Engineering and Machine Tools, Leibniz Universität Hannover, An der Universität 2, 30823 Garbsen (Germany); Seitz, Jan-Marten [Institute of Materials Science, Leibniz Universität Hannover, An der Universität 2, 30823 Garbsen (Germany); Reifenrath, Janin, E-mail: janin.reifenrath@tiho-hannover.de [Small Animal Clinic, University of Veterinary Medicine Hannover, Foundation, Bünteweg 9, 30559 Hannover (Germany)

    2015-04-01

    The use of absorbable implant materials for fixation after bone fracture helps to avoid a second surgery for implant removal and the risks and costs involved. Magnesium (Mg) is well known as a potential metallic material for degradable implants. The aim of the present in vitro study was to evaluate if degradable LAE442-based magnesium plate–screw-systems are suitable candidates for osteosynthesis implants in load-bearing bones. The corrosion behaviour was tested concerning the influence of different surface treatments, coatings and screw torques. Steel plates and screws of the same size served as control. Plates without special treatment screwed on up to a specified torque of 15 cNm or 7 cNm, NaOH treated plates (15 cNm), magnesium fluoride coated plates (15 cNm) and steel plates as control (15 cNm) were examined in pH-buffered, temperature-controlled SBF solution for two weeks. The experimental results indicate that the LAE442 plates and screws coated with magnesium fluoride revealed a lower hydrogen evolution in SBF solution as well as a lower weight loss and volume decrease in μ-computed tomography (μCT). The nanoindentation and SEM/EDX measurements at several plate areas showed no significant differences. Summarized, the different screw torques did not affect the corrosion behaviour differently. Also the NaOH treatment seemed to have no essential influence on the degradation kinetics. The plates coated with magnesium fluoride showed a decreased corrosion rate. Hence, it is recommended to consider this coating for the next in vivo study. - Highlights: • Mg-based plate screw systems were examined in an in vitro corrosion setup. • Different screw torques did not affect the corrosion behaviour. • Pretreatment with NaOH showed no increase in corrosion resistance. • Fluoride coating slowed down the corrosion rate of plates. • Fluoride coating might be an alternative for decrease of corrosion rate in vivo.

  13. Development of non-destructive examination system for irradiated fuel rods

    International Nuclear Information System (INIS)

    Sumerling, R.; Goldsmith, L.A.; Cross, M.T.; McKee, F.

    1978-12-01

    The development of non-destructive examination (NDE) system for irradiated fuel rods is described. The system is used for testing rods within a concrete cave and consists of three parts: a fully-automated fuel rod-drive machine, designed for easy maintenance; a series of plug-in NDE modules which fit into the central space provided in the machine, plus optical/TV viewing devices and gamma-scan equipment lined up on the rod; and on electronic control equipment situated outside the concrete shielding. The equipment is at present routinely used for viewing, eddy-current testing, gamma-scanning and diameter measurement of rods. The system is flexible in that additional modules can be added later as they are developed, since there is room for three modules of standard size (about 10cm x 10 cm x 3cm) in the machine or one large module taking the full space. New developments include the use of dual frequency eddy-current testing, which allows much greater discrimination against unwanted signals, and measurement of oxide thickness using a high frequency eddy-current probe. (author)

  14. New approach for control rod position indication system for light water power reactor

    International Nuclear Information System (INIS)

    Bahuguna, Sushil; Dhage, Sangeeta; Nawaj, S.; Salek, C.; Lahiri, S.K.; Marathe, P.P.; Mukhopadhyay, S.; Taly, Y.K.

    2015-01-01

    Control rod position indication system is an important system in a nuclear power plant to monitor and display control rod position in all regimes of reactor operation. A new approach to design a control rod position indication system for sensing absolute position of control rod in Light Water Power Reactor has been undertaken. The proposed system employs an inductive type, hybrid measurement strategy providing both analog position as well as digital zone indication with built-in temperature compensation. The new design approach meets single failure criterion through redundancy in design without sacrificing measurement resolution. It also provides diversity in measurement technique by indirect position sensing based on analysis of drive coil current signature. Prototype development and qualification at room temperature of the control rod position indication system (CRPIS) has been demonstrated. The article presents the design philosophy of control rod position indication system, the new measurement strategy for sensing absolute position of control rod, position estimation algorithm for both direct and indirect sensing and a brief account associated processing electronics. (author)

  15. Self-actuation type electromagnet for control rod retaining mechanism

    International Nuclear Information System (INIS)

    Saito, Makoto; Gunji, Minoru.

    1989-01-01

    The present invention concerns a self-actuation type electromagnet for automatically inserting a control rod into a reactor core for the reactor scram upon occurrence of abnormality in FBR type reactors, etc. That is, a mechanism for preventing scorching is disposed to an attracting portion of a split type core thereby enabling reliable detachment of a control rod. For this purpose, less scorching material is embedded to the attracting portion between each of the core portions, with the surface being slightly protruded. In such an attracting portion, a fine gap is formed between each of the core portions by the contact of less scorching materials. Further, the scorching material is embedded into a metal ring, which is screw-coupled to one of the core portions such that the position is adjustable in the direction of the control rod. Further, the less scorching material is made of alumina. As a result, the attracting portion is neither scorched or fused even when it is used for a long period of time in liquid sodium at high temperature. Therefore, when the electromagnet loses the attracting force, the control rod drops surely. (I.S.)

  16. Comparison of CPR1000 and AP1000 rod position indication systems

    International Nuclear Information System (INIS)

    Lei Qing

    2009-01-01

    This paper introduces the structure, the function, the digital detection principle of reactor control rod position and monitoring systems in CPR1000 and AP1000, comparing with the characteristics of the system design. The results show that the operation mode and function of AP1000 Rod position indication system are similar to that of CPR1000, but AP1000 rod position system provides higher reliability, and reduces the numbers of containment electrical penetrations and is with better characteristics than that of CPR1000, since it incorporated the redundancy design and data communication. (authors)

  17. Therapeutic efficacy of pedicle screw-rod internal fixation after one-stage posterior transforaminal lesion debridement and non-structural bone grafting for tuberculosis of lumbar vertebra

    Directory of Open Access Journals (Sweden)

    Jia-ming LIU

    2015-11-01

    Full Text Available Objective To evaluate the efficacy and safety of pedicle screw-rod internal fixation after one-stage posterior transforaminal lesion debridement and non-structural bone grafting in the treatment of tuberculosis of mono-segmental lumbar vertebra. Methods From January 2010 to April 2013, 21 patients (9 males and 12 females with an average age of 49.1 years with mono-segmental tuberculosis of lumbar vertebra underwent surgery in our hospital were included. Eight patients had neurological deficit. The focus of tuberculosis was located on one side of the vertebral body, and all the patients had obvious signs of bone destruction on CT and MRI. All the patients were given anti-tuberculosis chemotherapy for 2-3 weeks before surgery. The local bone chips and autologous iliac cancellous bone were used as the intervertebral bone graft. Postoperative plain radiographs and CT were obtained to evaluate the fusion rate and degree of lumbar lordosis. The visual analogue scale score (VAS, erythrocyte sedimentation rate (ESR, and C-reactive protein (CRP before and after operation, and at final follow-up date were recorded. Results All the patients were followed up for 25.3±4.2 months. The mean operation time was 157±39 minutes, and the average blood loss was 470±143ml. The fusion rate of the interbody bone graft was 95.2%, with an average fusion period of 6.1±2.5 months. The neurological function was improved by 100%, and no severe complication or neurological injury occured. The preoperative and postoperative lordosis angles of the lumbar spine were 21.4°±5.7° and 33.6°±3.1°, respectively, and it was 31.3°±2.7° at the final follow up. The preoperative and postoperative VAS scores were 7.8±2.6 and 2.4±1.7 respectively, and it was 0.9±0.7 at the final follow up. The ESR and CRP were significantly decreased 3 months after surgery, and they became normal at 6 months. Conclusion Pedicle screw-rod internal fixation after one-stage posterior

  18. Development of a DIPG Orthotopic Model in Mice Using an Implantable Guide-Screw System.

    Directory of Open Access Journals (Sweden)

    Miguel Marigil

    Full Text Available In this work we set to develop and to validate a new in vivo frameless orthotopic Diffuse Intrinsic Pontine Glioma (DIPG model based in the implantation of a guide-screw system.It consisted of a guide-screw also called bolt, a Hamilton syringe with a 26-gauge needle and an insulin-like 15-gauge needle. The guide screw is 2.6 mm in length and harbors a 0.5 mm central hole which accepts the needle of the Hamilton syringe avoiding a theoretical displacement during insertion. The guide-screw is fixed on the mouse skull according to the coordinates: 1mm right to and 0.8 mm posterior to lambda. To reach the pons the Hamilton syringe is adjusted to a 6.5 mm depth using a cuff that serves as a stopper. This system allows delivering not only cells but also any kind of intratumoral chemotherapy, antibodies or gene/viral therapies.The guide-screw was successfully implanted in 10 immunodeficient mice and the animals were inoculated with DIPG human cell lines during the same anesthetic period. All the mice developed severe neurologic symptoms and had a median overall survival of 95 days ranging the time of death from 81 to 116 days. Histopathological analysis confirmed tumor into the pons in all animals confirming the validity of this model.Here we presented a reproducible and frameless DIPG model that allows for rapid evaluation of tumorigenicity and efficacy of chemotherapeutic or gene therapy products delivered intratumorally to the pons.

  19. Allogenic bone rods with freeze drying and gamma rays irradiation for treatment of fracture

    International Nuclear Information System (INIS)

    Zhou Zhenbin

    1999-01-01

    Opened reduction and internal fixation are the usual treatment of fracture, but both methods need a second operation for removal implants. The benefits of the bone rods are that they can avoid the removement of internal fixation and will be absorbed spontaneously. The bone rods are made of allogeneic compact bones with freeze-drying and gamma rays irradiation supplied by Shanxi Provincial Tissue Bank. The purpose of this study is to evaluate allograft reaction, the stability of the internal fixation, osteoinduction in the treatment of fracture using allogeneic bone rods with freeze drying and gamma rays irradiation. From May 1997 to May 1998, fourteen cases (male 12, female 2) of treatment were reviewed. The mean age was 37.3 (21-5 1). There were 3 medial malleolus fractures, 7 tibia and fibula fractures, 1 ulna and radius fracture, 1 lateral condyle of humerus fracture. The clinical results were satisfactory. Because the strength of the bone rods are weaker than that of screws, the bone rods are only indicated in the fixation of cancellous bones fracture and unloaded bone fracture. It can be used as a supplementary fixation of loaded bone. It is not indicated for fixation of comminuted fracture. More than two bone rods may be used in the fixation of fracture in order to get stability of the fracture and decrease stress between rods which will prevent the break of the bone rods. Allogeneic bone rods with freeze-drying and gamma rays irradiation can be used as implants of non-immunogenicity. There are no allograft reactions in all cases (including fever, leukocytosis, exudation or swelling in the wound). Although plenty of experimental studies have showed that freeze drying with gamma rays irradiation (below 50 KGy) would not destroy BMP of bone allograft, but there is no osteoinduction in our cases. The healing of a fracture and bridging external callus are similar as other operations. This new technique may have the following advantages compare with the screws: 1

  20. A uniquely shaped rod improves curve correction in surgical treatment of adolescent idiopathic scoliosis

    DEFF Research Database (Denmark)

    Gehrchen, Poul Martin; Ohrt-Nissen, Søren; Hallager, Dennis Winge

    2016-01-01

    . Posterior fusion using all pedicle screw instrumentation has become the standard for the surgical treatment of AIS. Traditionally, the rod is circular in the cross-sectional plane. Recent biomechanical studies suggest that a beam-like structure of the rod may enhance the stiffness of the construct...... correction, sagittal balance, or coronal balance (P>0.058). A postoperative decrease in thoracic kyphosis was seen with no significant difference between groups. Median T5-T12 change was -7° versus -3° for BR and CR, respectively (P=0.051).  Conclusion. A BR design results in a significantly better curve...

  1. Advantages of Westinghouse BWR control rod drop accidents methodology utilizing integrated POLCA-T code

    International Nuclear Information System (INIS)

    Panayotov, Dobromir

    2008-01-01

    The paper focuses on the activities pursued by Westinghouse in the development and licensing of POLCA-T code Control Rod Drop Accident (CRDA) Methodology. The comprehensive CRDA methodology that utilizes PHOENIX4/POLCA7/POLCA-T calculation chain foresees complete cycle-specific analysis. The methodology consists of determination of candidates of control rods (CR) that could cause a significant reactivity excursion if dropped throughout the entire fuel cycle, selection of limiting initial conditions for CRDA transient simulation and transient simulation itself. The Westinghouse methodology utilizes state-of-the-art methods. Unnecessary conservatisms in the methodology have been avoided to allow the accurate prediction of margin to design bases. This is mainly achieved by using the POLCA-T code for dynamic CRDA evaluations. The code belongs to the same calculation chain that is used for core design. Thus the very same reactor, core, cycle and fuel data base is used. This allows also reducing the uncertainties of input data and parameters that determine the energy deposition in the fuel. Uncertainty treatment, very selective use of conservatisms, selection of the initial conditions for limiting case analyses, incorporation into POLCA-T code models of the licensed fuel performance code are also among the means of performing realistic CRDA transient analyses. (author)

  2. Automated nuclear fuel rod pattern loading system

    International Nuclear Information System (INIS)

    Lambert, D.V.; Nylund, T.W.; Byers, J.W.; Haley, D.E. Jr.; Cioffi, J.V.

    1991-01-01

    This patent describes a method for loading fuel rods in a desired pattern. It comprises providing a supply of fuel rods of known enrichments; providing a magazine defining a matrix of elongated slots open at their forward ends for receiving fuel rods; defining a fuel rod feed path; receiving successively one at a time along the feed path fuel rods selected from the supply thereof; verifying successively one at a time along the feed path the identity of the selected fuel rods, the verifying including blocking passage of each selected fuel rod along the feed path until the identity of each selected fuel rod is confirmed as correct; feeding to the magazine successively one at a time along the feed path the selective and verified fuel rods; and supporting and moving the magazine along X-Y axes to successively align one at a time selected ones of the slots with the feed path for loading in the magazine the successive fuel rods in a desired enrichment pattern

  3. Nuclear reactor internals construction and failed fuel rod detection system

    International Nuclear Information System (INIS)

    Frisch, E.; Andrews, H.N.

    1976-01-01

    A system is provided for determining during operation of a nuclear reactor having fluid pressure operated control rod mechanisms the exact location of a fuel assembly with a defective fuel rod. The construction of the reactor internals is simplified in a manner to facilitate the testing for defective fuel rods and the reduce the cost of producing the upper internals of the reactor. 13 claims, 10 drawing figures

  4. Fixation strength of biocomposite wedge interference screw in ACL reconstruction: effect of screw length and tunnel/screw ratio. A controlled laboratory study

    Directory of Open Access Journals (Sweden)

    Herrera Antonio

    2010-06-01

    Full Text Available Abstract Background Primary stability of the graft is essential in anterior cruciate ligament surgery. An optimal method of fixation should be easy to insert and provide great resistance against pull-out forces. A controlled laboratory study was designed to test the primary stability of ACL tendinous grafts in the tibial tunnel. The correlation between resistance to traction forces and the cross-section and length of the screw was studied. Methods The tibial phase of ACL reconstruction was performed in forty porcine tibias using digital flexor tendons of the same animal. An 8 mm tunnel was drilled in each specimen and two looped tendons placed as graft. Specimens were divided in five groups according to the diameter and length of the screw used for fixation. Wedge interference screws were used. Longitudinal traction was applied to the graft with a Servohydraulic Fatigue System. Load and displacement were controlled and analyzed. Results The mean loads to failure for each group were 295,44 N (Group 1; 9 × 23 screw, 564,05 N (Group 2; 9 × 28, 614,95 N (Group 3; 9 × 35, 651,14 N (Group 4; 10 × 28 and 664,99 (Group 5; 10 × 35. No slippage of the graft was observed in groups 3, 4 and 5. There were significant differences in the load to failure among groups (ANOVA/P Conclusions Longer and wider interference screws provide better fixation in tibial ACL graft fixation. Short screws (23 mm do not achieve optimal fixation and should be implanted only with special requirements.

  5. Novel free-hand T1 pedicle screw method: Review of 44 consecutive cases

    Directory of Open Access Journals (Sweden)

    Mark A Rivkin

    2014-01-01

    Full Text Available Summary of Background Data: Multilevel posterior cervical instrumented fusions are becoming more prevalent in current practice. Biomechanical characteristics of the cervicothoracic junction may necessitate extending the construct to upper thoracic segments. However, fixation in upper thoracic spine can be technically demanding owing to transitional anatomy while suboptimal placement facilitates vascular and neurologic complications. Thoracic instrumentation methods include free-hand, fluoroscopic guidance, and CT-based image guidance. However, fluoroscopy of upper thoracic spine is challenging secondary to vertebral geometry and patient positioning, while image-guided systems present substantial financial commitment and are not readily available at most centers. Additionally, imaging modalities increase radiation exposure to the patient and surgeon while potentially lengthening surgical time. Materials and Methods: Retrospective review of 44 consecutive patients undergoing a cervicothoracic fusion by a single surgeon using the novel free-hand T1 pedicle screw technique between June 2009 and November 2012. A starting point medial and cephalad to classic entry as well as new trajectory were utilized. No imaging modalities were employed during screw insertion. Postoperative CT scans were obtained on day 1. Screw accuracy was independently evaluated according to the Heary classification. Results: In total, 87 pedicle screws placed were at T1. Grade 1 placement occurred in 72 (82.8% screws, Grade 2 in 4 (4.6% screws and Grade 3 in 9 (10.3% screws. All Grade 2 and 3 breaches were <2 mm except one Grade 3 screw breaching 2-4 mm laterally. Only two screws (2.3% were noted to be Grade 4, both breaching medially by less than 2 mm. No new neurological deficits or returns to operating room took place postoperatively. Conclusions: This modification of the traditional starting point and trajectory at T1 is safe and effective. It attenuates additional bone

  6. Rolls-Royce digital Rod Control System

    International Nuclear Information System (INIS)

    Pouillot, M.

    2010-01-01

    Full text of publication follows: Rolls-Royce has developed a new generation of Rod Control System, based on 40 years of experience. The fifth-generation Rod Control System (RCS) from Rolls-Royce offers a reliable, modular design with adaptability to your preferred platform, for modernization projects or new reactors. Flexible implementation provides the option for you to keep existing cabinets, which permits you to optimize installation approach. Main features for the power part: - Control Rod Drive Mechanism (CRDM) type: 3-coil. - Independent control of each sub-bank. - Each sub-bank is controlled by a cycler unit and 3 identical power racks, each including 4 identical power modules and a common power-supply module. - Coil-per-coil digital control: each power module embeds power-conversion, current-control, and current-monitoring functions for one coil. Control and monitoring are carried out by separate electronics in the module. Current is digitized and fully monitored by means of min-max templates. - A double-hold function is included: a power module assigned to a gripper will activate its coil if a fault risking to cause a reactor trip occurs. - Power modules are standardized, hot-pluggable and self-configured: a power module includes a set of parameters for each type of coil SG, MG, LC. The module recognizes the rack it is plugged in, and chooses automatically parameters to be used. Main benefits: - Reduced operational, maintenance, training, and inventory costs: standardization of power modules and integration of control and monitoring on the same PC-card lead to a drastic reduction of spare part types, and simplification of the system. - Easy maintenance: - Replacement of a power module solves nearly all failures due to current control or monitoring for a coil. It is done instantly thanks to hot-plug capability. - On the front plate of power-modules, LEDs provide useful information for diagnostic: current setpoint from cycler, output current bar

  7. Effects of Screw Configuration on the Preload Force of Implant-Abutment Screws.

    Science.gov (United States)

    Zipprich, Holger; Rathe, Florian; Pinz, Sören; Schlotmann, Luca; Lauer, Hans-Christoph; Ratka, Christoph

    The aim of this study was to investigate the effects of tightening torque, screw head angle, and thread number on the preload force of abutment screws. The test specimens consisted of three self-manufactured components (ie, a thread sleeve serving as an implant analog, an abutment analog, and an abutment screw). The abutment screws were fabricated with metric M1.6 external threads. The thread number varied between one and seven threads. The screw head angles were produced in eight varying angles (30 to 180 degrees). A sensor unit simultaneously measured the preload force of the screw and the torsion moment inside the screw shank. The tightening of the screw with the torque wrench was performed in five steps (15 to 35 Ncm). The torque wrench was calibrated before each step. Only the tightening torque and screw head angle affected the resulting preload force of the implant-abutment connection. The thread number had no effect. There was an approximately linear correlation between tightening torque and preload force. The tightening torque and screw head angle were the only study parameters that affected the resulting preload force of the abutment screw. The results obtained from this experiment are valid only for a single torque condition. Further investigations are needed that analyze other parameters that affect preload force. Once these parameters are known, it will add value for a strong, but detachable connection between the implant and abutment. Short implants and flat-to-flat connections especially will benefit significantly from this knowledge.

  8. Comparison of two systems for rigidly connecting 2.0-mm bone screws to an implantable device : in vitro stability testing

    NARCIS (Netherlands)

    van Loon, JP; de Bont, LGM; Verkerke, GJ

    The stability of a screw-fixed implantable device can be improved by eliminating the freedom of movement between the screws and the device. Two systems have been developed for rigidly connecting 2.0-mm bone screws to an implantable device, and the aim of this study was to test and compare the

  9. Pressure equalization systems in pressurized water reactor fuel rods

    International Nuclear Information System (INIS)

    Steven, J.; Wunderlich, F.

    1979-01-01

    For the development of a pressure reduction system in PWR fuel rods the capability of charcoal to adsorb Helium, Xenon and Krypton at temperatures of about 300 0 C was investigated. The influence of the adsorption on fuel rod internal pressure and in creep strain on the tube was evaluated in a design study. (orig.) [de

  10. The nuclear fuel rod character recognition system based on neural network technique

    International Nuclear Information System (INIS)

    Kim, Woong-Ki; Park, Soon-Yong; Lee, Yong-Bum; Kim, Seung-Ho; Lee, Jong-Min; Chien, Sung-Il.

    1994-01-01

    The nuclear fuel rods should be discriminated and managed systematically by numeric characters which are printed at the end part of each rod in the process of producing fuel assembly. The characters are used to examine manufacturing process of the fuel rods in the inspection process of irradiated fuel rod. Therefore automatic character recognition is one of the most important technologies to establish automatic manufacturing process of fuel assembly. In the developed character recognition system, mesh feature set extracted from each character written in the fuel rod is employed to train a neural network based on back-propagation algorithm as a classifier for character recognition system. Performance evaluation has been achieved on a test set which is not included in a training character set. (author)

  11. Experimental Breeder Reactor-II automatic control-rod-drive system

    International Nuclear Information System (INIS)

    Christensen, L.J.

    1983-01-01

    A computer-controlled automatic control rod drive system (ACRDS) was designed and operated in EBR-II during reactor runs 121 and 122. The ACRDS was operated in a checkout mode during run 121 using a low worth control rod. During run 122 a high worth control rod was used to perform overpower transient tests as part of the LMFBR oxide fuels transient testing program. The testing program required an increase in power of 4 MW/s, a hold time of 12 minutes and a power decrease of 4 MW/s. During run 122, 13 power transients were performed

  12. Nuclear fuel rod loading apparatus

    International Nuclear Information System (INIS)

    King, H.B.; Macivergan, R.; Mckenzie, G.W.

    1980-01-01

    An apparatus incorporating a microprocessor control is provided for automatically loading nuclear fuel pellets into fuel rods commonly used in nuclear reactor cores. The apparatus comprises a split ''v'' trough for assembling segments of fuel pellets in rows and a shuttle to receive the fuel pellets from the split ''v'' trough when the two sides of the split ''v'' trough are opened. The pellets are weighed while in the shuttle, and the shuttle then moves the pellets into alignment with a fuel rod. A guide bushing is provided to assist the transfer of the pellets into the fuel rod. A rod carousel which holds a plurality of fuel rods presents the proper rod to the guide bushing at the appropriate stage in the loading sequence. The bushing advances to engage the fuel rod, and the shuttle advances to engage the guide bushing. The pellets are then loaded into the fuel rod by a motor operated push rod. The guide bushing includes a photocell utilized in conjunction with the push rod to measure the length of the row of fuel pellets inserted in the fuel rod

  13. Development of the predictive maintenance system prototype for the rod control system

    International Nuclear Information System (INIS)

    Lim, H. S.; Hong, H. P.; Koo, J. M.; Kim, Y. B.; Han, H. W.

    2003-01-01

    The demand for safety and reliability of Nuclear Power Plants (NPPs) has been constantly increasing and economical operation is also an important issue. Developing and adopting predictive maintenance technology for the major systems or equipment is considered as a way to achieve these goals. This paper describes the development of a predictive maintenance system prototype for the Rod Control System, which adopts an advanced methodology. Bayesian Belief Networks (BBN) has been adopted for the real time fault diagnosis and prediction of the system. Through a simulation test, it was confirmed that the prototype monitors and secures sound operability of rod drive mechanism and its control system, and also provides the predictive maintenance information

  14. Pullout characteristics of percutaneous pedicle screws with different cement augmentation methods in elderly spines: An in vitro biomechanical study.

    Science.gov (United States)

    Charles, Y P; Pelletier, H; Hydier, P; Schuller, S; Garnon, J; Sauleau, E A; Steib, J-P; Clavert, P

    2015-05-01

    Vertebroplasty prefilling or fenestrated pedicle screw augmentation can be used to enhance pullout resistance in elderly patients. It is not clear which method offers the most reliable fixation strength if axial pullout and a bending moment is applied. The purpose of this study is to validate a new in vitro model aimed to reproduce a cut out mechanism of lumbar pedicle screws, to compare fixation strength in elderly spines with different cement augmentation techniques and to analyze factors that might influence the failure pattern. Six human specimens (82-100 years) were instrumented percutaneously at L2, L3 and L4 by non-augmented screws, vertebroplasty augmentation and fenestrated screws. Cement distribution (2 ml PMMA) was analyzed on CT. Vertebral endplates and the rod were oriented at 45° to the horizontal plane. The vertebral body was held by resin in a cylinder, linked to an unconstrained pivot, on which traction (10 N/s) was applied until rupture. Load-displacement curves were compared to simultaneous video recordings. Median pullout forces were 488.5 N (195-500) for non-augmented screws, 643.5 N (270-1050) for vertebroplasty augmentation and 943.5 N (750-1084) for fenestrated screws. Cement augmentation through fenestrated screws led to significantly higher rupture forces compared to non-augmented screws (P=0.0039). The pullout force after vertebroplasty was variable and linked to cement distribution. A cement bolus around the distal screw tip led to pullout forces similar to non-augmented screws. A proximal cement bolus, as it was observed in fenestrated screws, led to higher pullout resistance. This cement distribution led to vertebral body fractures prior to screw pullout. The experimental setup tended to reproduce a pullout mechanism observed on radiographs, combining axial pullout and a bending moment. Cement augmentation with fenestrated screws increased pullout resistance significantly, whereas the fixation strength with the vertebroplasty

  15. Stress-strain state analysis and optimization of rod system under periodic pulse load

    Directory of Open Access Journals (Sweden)

    Grebenyuk Grigory

    2018-01-01

    Full Text Available The paper considers the problem of analysis and optimization of rod systems subjected to combined static and periodic pulse load. As a result of the study the analysis method was developed based on traditional approach to solving homogeneous matrix equations of state and a special algorithm for developing a particular solution. The influence of pulse parameters variations on stress-strain state of a rod system was analyzed. Algorithms for rod systems optimization were developed basing on strength recalculation and statement and solution of optimization problem as a problem of nonlinear mathematical programming. Recommendations are developed for efficient organization of process for optimization of rod systems under static and periodic pulse load.

  16. Positioning device for screwing or unscrewing screw nut

    International Nuclear Information System (INIS)

    Sevelinge, G.

    1987-01-01

    This automatic positioning device for screwing or unscrewing a screw nut on a closure stud has a drawed socket and means for axially centre and angularly by wedge the socket on the closure stud and generate a continuous spiral between the socket and the closure stud [fr

  17. Conceptual design of control rod regulating system for plate type fuels of Triga-2000 reactor

    International Nuclear Information System (INIS)

    Eko Priyono; Saminto

    2016-01-01

    Conceptual design of the control rod regulating system for plate type fuel of TRIGA-2000 reactor has been made. Conceptual design of the control rod regulating system for plate type fuel of TRIGA-2000 reactor was made with refer to study result of instrument and control system which is used in BATAN'S reactor. Conceptual design of the control rod regulating system for plate type fuel of TRIGA-2000 reactor consist of 4 segments that is control panel, translator, driver and display. Control panel is used for regulating, safety and display control rod, translator is used for signal processing from control panel, driver is used for driving control rod and display is used for display control rod level position. The translator was designed in 2 modes operation i.e operation by using PLC modules and IC TTL modules. These conceptual design can be used as one of reference of control rod regulating system detail design. (author)

  18. A consolidation process for spent burnable poison rod assemblies

    International Nuclear Information System (INIS)

    Yamamoto, Y.; Harada, M.; Komatsu, Y.

    1985-01-01

    A new consolidation system for the spent burnable poison assembly utilizing a sequence control robot operated under water was proposed. A credible accident in the system was analyzed mainly from the viewpoint of tritium release, based on the diffusion analysis of tritium in borosilicate glass. It was found that the amount of tritium released would be small even after the rupture of burnable poison rods. An experiment on a new consolidation system was performed using spent burnable poison assemblies. The volume of burnable poison assemblies was reduced safely and securely by a factor of 7 to 14 for burnable poison rods and by 22 for hold-down portions. It was proved that the consolidation system is collectively feasible

  19. Numerical study of internal flow in twin screw extruder and its mixing performance analysis

    International Nuclear Information System (INIS)

    Kim, Nak Soo; Kim, Hong Bum; Lee, Jae Wook

    2006-01-01

    We analyzed the non-Newtonian and non-isothermal flow in the melt conveying zone in co-rotating and counter-rotating screw extruder system with the commercial code, STAR-CD, and compared the mixing performance with respect to screw speed and rotating direction. The viscosity of fluid was described by power-law model. The dynamics of mixing was studied numerically by tracking the motion of particles in a twin screw extruder system. The extent of mixing was characterized in terms of the residence time distribution and average strain. The results showed that high screw speed decreases the residence time but increases the shear rate. Therefore higher screw speed increases the strain and has better mixing performance. Counter-rotating screw extruder system and co-rotating screw extruder has the similar shear rate with the same screw speed in spite of different rotating direction. However, the counter-rotating screw has good mixing performance, which is resulted from longer residence time than that of co-rotating screw extruder

  20. Are We Underestimating the Significance of Pedicle Screw Misplacement?

    Science.gov (United States)

    Sarwahi, Vishal; Wendolowski, Stephen F; Gecelter, Rachel C; Amaral, Terry; Lo, Yungtai; Wollowick, Adam L; Thornhill, Beverly

    2016-05-01

    A retrospective review of charts, x-rays (XRs) and computed tomography (CT) scans was performed. To evaluate the accuracy of pedicle screw placement using a novel classification system to determine potentially significant screw misplacement. The accuracy rate of pedicle screw (PS) placement varies from 85% to 95% in the literature. This demonstrates technical ability but does not represent the impact of screw misplacement on individual patients. This study quantifies the rate of screw misplacement on a per-patient basis to highlight its effect on potential morbidity. A retrospective review of charts, XRs and low-dose CT scans of 127 patients who underwent spinal fusion with pedicle screws for spinal deformity was performed. Screws were divided into four categories: screws at risk (SAR), indeterminate misplacements (IMP), benign misplacements (BMP), accurately placed (AP). A total of 2724 screws were placed in 127 patients. A total of 2396 screws were placed accurately (87.96%). A total of 247 screws (9.07%) were BMP, 52 (1.91%) were IMP, and 29 (1.06%) were considered SAR. Per-patient analysis showed 23 (18.11%) of patients had all screws AP. Thirty-five (27.56%) had IMP and 18 (14.17%) had SAR. Risk factor analysis showed smaller Cobb angles increased likelihood of all screws being AP. Sub-analysis of adolescent idiopathic scoliotic patients showed no curve or patient characteristic that correlated with IMP or SAR. Over 40% of patients had screws with either some/major concern. Overall reported screw misplacement is low, but it does not reflect the potential impact on patient morbidity. Per-patient analysis reveals more concerning numbers toward screw misplacement. With increasing pedicle screw usage, the number of patients with misplaced screws will likely increase proportionally. Better strategies need to be devised for evaluation of screw placement, including establishment of a national database of deformity surgery, use of intra-operative image guidance, and

  1. Effectiveness of the Thoracic Pedicle Screw Placement Using the Virtual Surgical Training System: A Cadaver Study.

    Science.gov (United States)

    Hou, Yang; Lin, Yanping; Shi, Jiangang; Chen, Huajiang; Yuan, Wen

    2018-03-14

    The virtual simulation surgery has initially exhibited its promising potentials in neurosurgery training. To evaluate effectiveness of the Virtual Surgical Training System (VSTS) on novice residents placing thoracic pedicle screws in a cadaver study. A total of 10 inexperienced residents participated in this study and were randomly assigned to 2 groups. The group using VSTS to learn thoracic pedicle screw fixation was the simulation training (ST) group and the group receiving an introductory teaching session was the control group. Ten fresh adult spine specimens including 6 males and 4 females with a mean age of 58.5 yr (range: 33-72) were collected and randomly allocated to the 2 groups. After exposing anatomic structures of thoracic spine, the bilateral pedicle screw placement of T6-T12 was performed on each cadaver specimen. The postoperative computed tomography scan was performed on each spine specimen, and experienced observers independently reviewed the placement of the pedicle screws to assess the incidence of pedicle breach. The screw penetration rates of the ST group (7.14%) was significantly lower in comparison to the control group (30%, P < .05). Statistically significant difference in acceptable rates of screws also occurred between the ST (100%) and control (92.86%) group (P < .05). In addition, the average screw penetration distance in control group (2.37 mm ± 0.23 mm) was significantly greater than ST group (1.23 mm ± 0.56 mm, P < .05). The virtual reality surgical training of thoracic pedicle screw instrumentation effectively improves surgical performance of novice residents compared to those with traditional teaching method, and can help new beginners to master the surgical technique within shortest period of time.

  2. Comparison of accuracy of lag screw placement in cephalocondylic nails and sliding hip screw plate fixation for extracapsular fractures of the neck of femur

    OpenAIRE

    Shyam Kumar, A. J.; Parmar, V.; Bankart, J.; Williams, S. C.; Harper, W. M.

    2006-01-01

    This study compared the accuracy of lag screw placement between extracapsular femoral fractures fixed with sliding hip screw plate systems and those fixed with cephalocondylic nails. It involved 75 retrospective radiographs of fractures fixed with either a cephalocondylic nail (32) or a sliding hip screw plate system (43). Postoperative anteroposterior and lateral radiographs of the hip were scanned using a digital X-ray scanner and measured using computer software. Measurements were conducte...

  3. Hydraulic screw fastening devices - design, maintenance, operational experience

    International Nuclear Information System (INIS)

    Lachner.

    1976-01-01

    With hydraulic screw fastening devices, pretension values with a maximum deviation of +-2.5% from the rated value can be achieved. This high degree of pretension accuracy is of considerable importance with regard to the safety factor required for the screw connection between reactor vessel head and reactor vessel. The operating rhythm of a nuclear power station with its refuelling art regular intervals makes further demands on the screw fastening device, in particular in connection with the transport of screws and for nuts. The necessary installations extend the screw fastening device into a combination of a high-pressure hydraulic cylinder system with an electrical or pneumoelectrical driving unit and an electrical control unit. Maintenance work is complicated by the large number of identical, highly stressed structural elements in connection with an unfavourable relation operating time/outage time. The problems have been perpetually reduced by close cooperation between the manufacturers and users of screw fastening devices. (orig./AK) [de

  4. Estimation and control in HTGR fuel rod fabrication

    International Nuclear Information System (INIS)

    Downing, D.J.; Bailey, M.J.

    1980-01-01

    A control algorithm has been derived for a HTGR Fuel Rod Fabrication Process utilizing the method of Box and Jenkins. The estimator is a Kalman filter and is compared with a Least Square estimator and a standard control chart. The effects of system delays are presented

  5. Development of a non-piston MR suspension rod for variable mass systems

    Science.gov (United States)

    Deng, Huaxia; Han, Guanghui; Zhang, Jin; Wang, Mingxian; Ma, Mengchao; Zhong, Xiang; Yu, Liandong

    2018-06-01

    The semi-active suspension systems for variable mass systems require long work stroke and variable damping, while the currently piston structure limits the work stroke for the magnetorheological (MR) dampers. The main work of this paper is to design a semi-active non-piston MR (NPMR) suspension rod for the reduction of the vibration of an automatic impeller washing machine, which is a typical variable mass system. The designed suspension rod locates in the suspension system that links the internal tub to the washing machine cabinet. The NPMR suspension rod includes a MR part and a air part. The MR part can provide low initial damping force and the unlimited work stroke compared with the piston MR damper. The hysteretic response tests and vibration performance evaluation with different loadings are conducted to verify the dynamic performance for the designed rod. The measured damping force of the MR part varies from 5 to 20 N. Studies of dehydration mode experiments of the washing machine indicate that its vibration acceleration with the NPMR suspension rods can reduce to half of the original passive ones in certain conditions.

  6. Failed fuel rod detection system and computerized manipulator during outages

    International Nuclear Information System (INIS)

    Boehm, H.H.; Foerch, H.

    1984-01-01

    During regular outages spent fuel assemblies need to be replaced and relocated within the core. Defective fuel rods in particular fuel assemblies have to be removed from further service and before delivery of such faulty fuel assemblies to a reprocessing plant. The system which Brown Boveri Reaktor GmbH and Krautkraemer have developed in the Federal Republic of Germany is capable of directly locating the defective rods in a proper fuel assembly. Inspection times are comparable to those of standard sipping methods, with the advantages of immediately available results and direct identification of the defective fuel rods. During the repair of fuel assemblies this system allows withdrawal of individual defective rods. With the sipping method all the fuel rods of a defective fuel assembly need to be removed and inspected by eddy current testing. During steam generator inspection and repair personnel are exposed to ample radiation. A remotely controlled, computerized manipulator was used to significantly reduce the radiation dose by automating steps in the procedures; at the same time inspection and repair times were reduced. The main features of the manipulator are a rigid component construction of the leg and two arms, and a resolver control for horizontal and vertical motion that enables rapid and accurate access to a desired tube (author)

  7. [Anterior odontoid screw fixation using intra-operative cone-beam computed tomography and navigation].

    Science.gov (United States)

    Castro-Castro, Julián

    2014-01-01

    The purpose of this study was to asses the value of intraoperative cone-beam CT (O-arm) and stereotactic navigation for the insertion of anterior odontoid screws. this was a retrospective review of patients receiving surgical treatment for traumatic odontoid fractures during a period of 18 months. Procedures were guided with O-arm assistance in all cases. The screw position was verified with an intraoperative CT scan. Intraoperative and clinical parameters were evaluated. Odontoid fracture fusion was assessed on postoperative CT scans obtained at 3 and 6 months' follow-up Five patients were included in this series; 4 patients (80%) were male. Mean age was 63.6 years (range 35-83 years). All fractures were acute type ii odontoid fractures. The mean operative time was 116minutes (range 60-160minutes). Successful screw placement, judged by intraoperative computed tomography, was attained in all 5 patients (100%). The average preoperative and postoperative times were 8.6 (range 2-22 days) and 4.2 days (range 3-7 days) respectively. No neurological deterioration occurred after surgery. The rate of bone fusion was 80% (4/5). Although this initial study evaluated a small number of patients, anterior odontoid screw fixation utilizing the O-arm appears to be safe and accurate. This system allows immediate CT imaging in the operating room to verify screw position. Copyright © 2014 Sociedad Española de Neurocirugía. Published by Elsevier España. All rights reserved.

  8. Tapping insertional torque allows prediction for better pedicle screw fixation and optimal screw size selection.

    Science.gov (United States)

    Helgeson, Melvin D; Kang, Daniel G; Lehman, Ronald A; Dmitriev, Anton E; Luhmann, Scott J

    2013-08-01

    There is currently no reliable technique for intraoperative assessment of pedicle screw fixation strength and optimal screw size. Several studies have evaluated pedicle screw insertional torque (IT) and its direct correlation with pullout strength. However, there is limited clinical application with pedicle screw IT as it must be measured during screw placement and rarely causes the spine surgeon to change screw size. To date, no study has evaluated tapping IT, which precedes screw insertion, and its ability to predict pedicle screw pullout strength. The objective of this study was to investigate tapping IT and its ability to predict pedicle screw pullout strength and optimal screw size. In vitro human cadaveric biomechanical analysis. Twenty fresh-frozen human cadaveric thoracic vertebral levels were prepared and dual-energy radiographic absorptiometry scanned for bone mineral density (BMD). All specimens were osteoporotic with a mean BMD of 0.60 ± 0.07 g/cm(2). Five specimens (n=10) were used to perform a pilot study, as there were no previously established values for optimal tapping IT. Each pedicle during the pilot study was measured using a digital caliper as well as computed tomography measurements, and the optimal screw size was determined to be equal to or the first size smaller than the pedicle diameter. The optimal tap size was then selected as the tap diameter 1 mm smaller than the optimal screw size. During optimal tap size insertion, all peak tapping IT values were found to be between 2 in-lbs and 3 in-lbs. Therefore, the threshold tapping IT value for optimal pedicle screw and tap size was determined to be 2.5 in-lbs, and a comparison tapping IT value of 1.5 in-lbs was selected. Next, 15 test specimens (n=30) were measured with digital calipers, probed, tapped, and instrumented using a paired comparison between the two threshold tapping IT values (Group 1: 1.5 in-lbs; Group 2: 2.5 in-lbs), randomly assigned to the left or right pedicle on each

  9. [Fracture of implant abutment screws and removal of a remaining screw piece

    NARCIS (Netherlands)

    Broeke, S.M. van den; Baat, C. de

    2008-01-01

    Fracture of the implant abutment screws is a complication which can render an implant useless. The prevalence of abutment screw fracture does not exceed 2.5% after 10 years. Causes are loosening of implant abutment screw, too few, too short or too narrow implants, implants not inserted perpendicular

  10. Noise problems in PFR safety system power supplies

    Energy Technology Data Exchange (ETDEWEB)

    Hodgson, D

    1978-08-15

    Reactor power on PFR is controlled by eleven neutron absorbing rods. They are held vertically above the core by electromagnets which, in turn, are mounted on motorised lead screws. Five of the rods are used as power control elements; five are used as shut off rods and the eleventh is a safety rod, positioned vertically above the centre of the reactor core. All rods fall under gravity into the reactor when the electro magnets are de-energised. In addition the safety rod can be driven into the reactor by a pneumatic piston and cylinder mechanism. This provides some degree of diversity from the common design of mechanism used by the control and shut off rods. Also being in the center it can be armed and ready for use when the above core shield is rotated. The automatic protective system for the plant provides the electro magnet currents and hence the reactor trip signals via two separate and diverse safety systems, namely a ''Relay System'' and a ''Solid State System.'' The two systems are completely separate and independent. The overall probability of failure of the complete system to release at least 3 rods when called upon to do so is less than 10/sup -6/.

  11. Biomechanical analysis of titanium fixation plates and screws in ...

    African Journals Online (AJOL)

    hole Y plates with monocortical screws. 150 N incisal occlusal loads were simulated on the models. The commercial ANSYS software was utilized to calculate the Von Mises stresses on fixative appliances. Results: The highest Von Mises stress ...

  12. Polyetheretherketone (PEEK) Rods in Lumbar Spine Degenerative Disease: A Case Series.

    Science.gov (United States)

    Ormond, D Ryan; Albert, Ladislau; Das, Kaushik

    2016-08-01

    Retrospective case series. The purpose of our study was to retrospectively review the results of posterior lumbar fusion using polyetheretherketone (PEEK) rods. Pedicle screw and rod instrumentation has become the preferred technique for performing stabilization and fusion in the lumbar spine for degenerative disease. Rigid fixation with titanium rods leads to high fusion rates, but may also contribute to stress shielding and adjacent segment degeneration (ASD). Thus, some have advocated using semirigid rods made of PEEK. Although the biomechanical properties of PEEK rods have shown improved stress-shielding characteristics and anterior load-sharing properties, there are very few clinical studies evaluating their application in the lumbar spine. We evaluated a retrospective cohort of 42 patients who underwent posterior lumbar fusion from 2007 to 2009 for the treatment of lumbar spine degenerative disease using PEEK rods. Reoperation rate was the primary outcome evaluated. Fusion rate was also evaluated. Eight of the 42 patients with PEEK rods required reoperation. Reasons for reoperation mainly included ASD (5/8) and nonunion with cage migration (3/8). Radiographically, documented fusion rate was 86%. Mean follow-up was 31.4 months. No statistical differences were found in fusion rates or reoperation between age above 55 years and younger than 55 years (P=1.00), male and female (P=0.110), single or multilevel fusion (P=0.67), and fusion with and without an interbody graft (P=0.69). Smokers showed a trend towards increased risk of reoperation for ASD or instrumentation failure (P=0.056). PEEK rods demonstrate a similar fusion and reoperation rate in comparison to other instrumentation modalities in the treatment of degenerative lumbar spine disease.

  13. Effect of Repeated Screw Joint Closing and Opening Cycles and Cyclic Loading on Abutment Screw Removal Torque and Screw Thread Morphology: Scanning Electron Microscopy Evaluation.

    Science.gov (United States)

    Arshad, Mahnaz; Mahgoli, Hosseinali; Payaminia, Leila

    To evaluate the effect of repeated screw joint closing and opening cycles and cyclic loading on abutment screw removal torque and screw thread morphology using scanning electron microscopy (SEM). Three groups (n = 10 in each group) of implant-abutment-abutment screw assemblies were created. There were also 10 extra abutment screws as new screws in group 3. The abutment screws were tightened to 12 Ncm with an electronic torque meter; then they were removed and removal torque values were recorded. This sequence was repeated 5 times for group 1 and 15 times for groups 2 and 3. The same screws in groups 1 and 2 and the new screws in group 3 were then tightened to 12 Ncm; this was also followed by screw tightening to 30 Ncm and retightening to 30 Ncm 15 minutes later. Removal torque measurements were performed after screws were subjected to cyclic loading (0.5 × 10⁶ cycles; 1 Hz; 75 N). Moreover, the surface topography of one screw from each group before and after cyclic loading was evaluated with SEM and compared with an unused screw. All groups exhibited reduced removal torque values in comparison to insertion torque in each cycle. However, there was a steady trend of torque loss in each group. A comparison of the last cycle of the groups before loading showed significantly greater torque loss value in the 15th cycle of groups 2 and 3 compared with the fifth cycle of group 1 (P abutment is definitively placed.

  14. Digital control rod blocking monitor

    International Nuclear Information System (INIS)

    Funayama, Yoshio.

    1996-01-01

    The present invention system is used for monitoring of a power region of a reactor, and used for monitoring of simultaneous withdrawal of a plurality of control rods without increasing the size or complicating the system. Namely, the system processes signals from a neutron flux detectors at the periphery of control rods controlled for withdrawal. As a result of the processing, the digital monitoring system generates an alarm when the reactor power at the periphery of the control rods fluctuates exceeding an allowable range. In the system, a control rod information forming means prepares frame data comprising front data, positions of the control rods to be withdrawn, frame numbers and completion data. A serial data transmitting means transmits the frame data successively as repeating frame data rows. A control rod information receiving means takes up the frame data of each of control rods to be withdrawn from the transmitted frame data rows. Since the system of the present invention can monitor the withdrawal of a plurality of control rods simultaneously without increasing the size or complicating the system, cost can be saved and the maintenance can be improved. (I.S.)

  15. A novel magnetic lead screw active suspension system for vehicles

    DEFF Research Database (Denmark)

    Berg, Nick Ilsø; Holm, Rasmus Koldborg; Rasmussen, Peter Omand

    2014-01-01

    This paper encompasses a detailed study of the redesign of a novel Magnetic Lead Screw (MLS) active suspension system for possible regeneration of the energy dispatched in the suspension system and active control of vehicle body movement. The MLS converts a low speed high force linear motion...... of a translator into a high speed low torque rotational motion of a rotor through helically shaped magnets. The paper describes the drawback of the first MLS prototype v1.0 developed for active suspension system, which lead to a new design of the MLS prototype named v1.5. Furthermore the paper introduces detailed...

  16. Practical use of control rod calibration system with the inverse kinetics method

    International Nuclear Information System (INIS)

    Yamanaka, Haruhiko; Hayashi, Kazuhiko; Motohashi, Jun; Kawashima, Kazuhito; Ichimura, Toshiyuki; Tamai, Kazuo; Takeuti, Mitsuo

    2002-01-01

    The control rod calibration results in the JRR-3 are used as a reactivity standard to measure and manage the reactivity change in the core. The total travel of all six control rods has been calibrated by an inverse kinetics method (IK method) during an annual maintenance period. The IK method has the great merit in saving measuring time compared with the conventional positive period method (PP method). The JRR-3 control rod calibration system was renovated and put into practical use in order to improve reliability and function by accumulating 10-year experience with the IK method in the JRR-3. The report shows the function, the performance and results of verification of the JRR-3 control rod calibration system. (author)

  17. [Direct repair of adolescent lumbar spondylolysis using a pedicle screw-laminar hook system by paramedian approach].

    Science.gov (United States)

    Wang, Bin; Tang, Yong-hua; Tang, Hong-chao; Jin, Cai-yi

    2011-08-01

    To discuss the indication and clinical effect of direct repair of adolescent lumbar spondylolysis by screw-laminar hook system. From August 2003 to December 2008, 28 patients (13 males and 15 females,ranging in age from 15 and 26 years, averaged 21.6 years) with lumbar spondylolysis were treated with isthmic bone grafting and internal fixation with a pedicle screw-laminar hook system. Three patients had spondylolysis at L3, L4; 5 patients had spondylolysis at L4, L5; 8 patients had spondylolysis at L4; and 12 patients had spondylolysis at L5. All the patients had low back pain and lasted over 6 months. According to preoperative and postoperative plain radiograph, CT scan and Macnab criteria, the fusion rate and clinical effect of this technique were evaluated. All the patients were followed up with a mean period of 14.9 months, ranging from 9 to 24 months. All the patients had bony union according to the X-rays and CT scan. According to the calculation results of Macnab criteria, 22 patients got an excellent result, 5 good and 1 fair. The direct repair of adolescent lumbar spondylolysis with pedicle screw-laminar hook system can shorten length of operation,decrease blood loss, preserve more posterior structures of spine and avoid iatrogenic instability of spine. The postoperative immediate stability of vertebral segment is acquired and the mobility of adjacent intervertebral discs is reserved. The screw-laminar hook system for the treatment of adolescent spondylolisthesis can get satisfactory clinical results.

  18. Degradation behaviour of LAE442-based plate-screw-systems in an in vitro bone model.

    Science.gov (United States)

    Wolters, Leonie; Besdo, Silke; Angrisani, Nina; Wriggers, Peter; Hering, Britta; Seitz, Jan-Marten; Reifenrath, Janin

    2015-04-01

    The use of absorbable implant materials for fixation after bone fracture helps to avoid a second surgery for implant removal and the risks and costs involved. Magnesium (Mg) is well known as a potential metallic material for degradable implants. The aim of the present in vitro study was to evaluate if degradable LAE442-based magnesium plate-screw-systems are suitable candidates for osteosynthesis implants in load-bearing bones. The corrosion behaviour was tested concerning the influence of different surface treatments, coatings and screw torques. Steel plates and screws of the same size served as control. Plates without special treatment screwed on up to a specified torque of 15cNm or 7cNm, NaOH treated plates (15cNm), magnesium fluoride coated plates (15cNm) and steel plates as control (15cNm) were examined in pH-buffered, temperature-controlled SBF solution for two weeks. The experimental results indicate that the LAE442 plates and screws coated with magnesium fluoride revealed a lower hydrogen evolution in SBF solution as well as a lower weight loss and volume decrease in μ-computed tomography (μCT). The nanoindentation and SEM/EDX measurements at several plate areas showed no significant differences. Summarized, the different screw torques did not affect the corrosion behaviour differently. Also the NaOH treatment seemed to have no essential influence on the degradation kinetics. The plates coated with magnesium fluoride showed a decreased corrosion rate. Hence, it is recommended to consider this coating for the next in vivo study. Copyright © 2015 Elsevier B.V. All rights reserved.

  19. Automated nuclear fuel rod pattern loading system

    International Nuclear Information System (INIS)

    Lambert, D.V.; Nyland, T.W.; Byers, J.W.; Haley, D.E. Jr.; Cioffi, J.V.

    1990-01-01

    This patent describes an apparatus for loading fuel rods in a desired pattern. It comprises: a carousel having a plurality of movable gondolas for stocking thereon fuel rods of known enrichments; an elongated magazine defining a matrix of elongated slots being open at their forward ends for receiving fuel rods; a workstation defining a fuel rod feed path; and a holder and indexing mechanism for movably supporting the magazine and being actuatable for moving the magazine along X-Y axes to successively align one at a time selected ones of the slots with the feed path for loading in the magazine the successive fuel rods in a desired enrichment pattern

  20. Comparison of the load-sharing characteristics between pedicle-based dynamic and rigid rod devices

    International Nuclear Information System (INIS)

    Ahn, Yoon-Ho; Chen, W-M; Lee, Kwon-Yong; Park, Kyung-Woo; Lee, Sung-Jae

    2008-01-01

    Recently, numerous types of posterior dynamic stabilization (PDS) devices have been introduced as an alternative to the fusion devices for the surgical treatment of degenerative lumbar spine. It is hypothesized that the use of 'compliant' materials such as Nitinol (Ni-Ti alloy, elastic modulus = 75 GPa) or polyether-etherketone (PEEK, elastic modulus = 3.2 GPa) in PDS can restore stability of the lumbar spine without adverse stress-shielding effects that have often been found with 'rigid' fusion devices made of 'rigid' Ti alloys (elastic modulus = 114 GPa). Previous studies have shown that suitably designed PDS devices made of more compliant material may be able to help retain kinematic behavior of the normal spine with optimal load sharing between the anterior and posterior spinal elements. However, only a few studies on their biomechanical efficacies are available. In this study, we conducted a finite-element (FE) study to investigate changes in load-sharing characteristics of PDS devices. The implanted models were constructed after modifying the previously validated intact model of L3-4 spine. Posterior lumbar fusion with three different types of pedicle screw systems was simulated: a conventional rigid fixation system (Ti6Al4V, Φ = 6.0 mm) and two kinds of PDS devices (one with Nitinol rod with a three-coiled turn manner, Φ = 4.0 mm; the other with PEEK rod with a uniform cylindrical shape, Φ = 6.0 mm). To simulate the load on the lumbar spine in a neutral posture, an axial compressive load (400 N) was applied. Subsequently, the changes in load-sharing characteristics and stresses were investigated. When the compressive load was applied on the implanted models (Nitinol rod, PEEK rod, Ti-alloy rod), the predicted axial compressive loads transmitted through the devices were 141.8 N, 109.8 N and 266.8 N, respectively. Axial forces across the PDS devices (Nitinol rod, PEEK rod) and rigid system (Ti-alloy rod) with facet joints were predicted to take over 41%, 33

  1. [Clinical application of accurate placement of lumbar pedicle screws using three-dimensional printing navigational templates under Quadrant system].

    Science.gov (United States)

    Chen, Xuanhuang; Yu, Zhengxi; Wu, Changfu; Li, Xing; Chen, Xu; Zhang, Guodong; Zheng, Zugao; Lin, Haibin

    2017-02-01

    To explore the feasibility and the effectiveness of the accurate placement of lumbar pedicle screws using three-dimensional (3D) printing navigational templates in Quadrant minimally invasive system. The L 1-5 spines of 12 adult cadavers were scanned using CT. The 3D models of the lumbar spines were established. The screw trajectory was designed to pass through the central axis of the pedicle by using Mimics software. The navigational template was designed and 3D-printed according to the bony surface where the soft tissues could be removed. The placed screws were scanned using CT to create the 3D model again after operation. The 3D models of the designed trajectory and the placed screws were registered to evaluate the placed screws coincidence rate. Between November 2014 and November 2015, 31 patients with lumbar instability accepted surgery assisted with 3D-printing navigation module under Quadrant minimally invasive system. There were 14 males and 17 females, aged from 42 to 60 years, with an average of 45.2 years. The disease duration was 6-13 months (mean, 8.8 months). Single segment was involved in 15 cases, two segments in 13 cases, and three segments in 3 cases. Preoperative visual analogue scale (VAS) was 7.59±1.04; Oswestry disability index (ODI) was 76.21±5.82; and the Japanese Orthopaedic Association (JOA) score was 9.21±1.64. A total of 120 screws were placed in 12 cadavers specimens. The coincidence rate of placed screw was 100%. A total of 162 screws were implanted in 31 patients. The operation time was 65-147 minutes (mean, 102.23 minutes); the intraoperative blood loss was 50-116 mL (mean, 78.20 mL); and the intraoperative radiation exposure time was 8-54 seconds (mean, 42 seconds). At 3-7 days after operation, CT showed that the coincidence rate of the placed screws was 98.15% (159/162). At 4 weeks after operation, VAS, ODI, and JOA score were 2.24±0.80, 29.17±2.50, and 23.43±1.14 respectively, showing significant differences when compared

  2. Failure Diagnosis System for a Ball-Screw by Using Vibration Signals

    Directory of Open Access Journals (Sweden)

    Won Gi Lee

    2015-01-01

    Full Text Available Recently, in order to reduce high maintenance costs and to increase operating ratio in manufacturing systems, condition-based maintenance (CBM has been developed. CBM is carried out with indicators, which show equipment’s faults and performance deterioration. In this study, indicator signal acquisition and condition monitoring are applied to a ball-screw-driven stage. Although ball-screw is a typical linearly reciprocating part and is widely used in industry, it has not gained attention to be diagnosed compared to rotating parts such as motor, pump, and bearing. First, the vibration-based monitoring method, which uses vibration signal to monitor the condition of a machine, is proposed. Second, Wavelet transform is used to analyze the defect signals in time-frequency domain. Finally, the failure diagnosis system is developed using the analysis, and then its performance is evaluated. Using the system, we estimated the severity of failure and detect the defect position. The low defect frequency (≈58.7 Hz is spread all over the time in the Wavelet-filtered signal with low frequency range. Its amplitude reflects the progress of defect. The defect position was found in the signal with high frequency range (768~1,536 Hz. It was detected from the interval between abrupt changes of signal.

  3. Results of automatic system implementation for the friction control rods execution in Cofrentes nuclear power plant

    International Nuclear Information System (INIS)

    Curiel, M.; Palomo, M. J.; Urrea, M.; Arnaldos, A.

    2010-10-01

    The purpose of this presentation is to show the obtained results in Cofrentes nuclear power plant (Spain) of control rods Pcc/24 friction test procedure. In order to perform this, a control rod friction test system has been developed. Principally, this system consists on software and data acquisition hardware that obtains and analyzes the control rod pressure variation on which the test is being made. The Pcc/24 procedure objective is to detect an excessive friction in the control rod movement that could cause a control rod drive movement slower than usual. This test is necessary every time that an anomalous alteration is produced in the reactor core that could affect to a fuel rod, and it is executed before the time measure of control rods rapid scram test of the affected rods. This test has to be carried out to all the reactor control rods and takes valuable time during plant refuelling. So, by means of an automatic system to perform the test, we obtain an important time saving during refuelling. On the other hand, the on-line monitoring of the control rod insertion and changes in differential pressure, permits a control rod operation fast and safe validation. Moreover, an automatic individual report of every rod is generated by the system and a final global result report of the entire test developed in refuelling is generated. The mentioned reports can be attached directly to the procedure documents obtaining an office data processing important saving time. (Author)

  4. Results of automatic system implementation for the friction control rods execution in Cofrentes nuclear power plant

    Energy Technology Data Exchange (ETDEWEB)

    Curiel, M. [Logistica y Acondicionamientos Industriales SAU, Sorolla Center, local 10, Av. de las Cortes Valencianas, 46015 Valencia (Spain); Palomo, M. J. [ISIRYM, Universidad Politecnica de Valencia, Camino de Vera s/n, Valencia (Spain); Urrea, M. [Iberdrola Generacion S. A., Central Nuclear Cofrentes, Carretera Almansa Requena s/n, 04662 Cofrentes, Valencia (Spain); Arnaldos, A., E-mail: m.curiel@lainsa.co [TITANIA Servicios Tecnologicos SL, Sorolla Center, local 10, Av. de las Cortes Valencianas No. 58, 46015 Valencia (Spain)

    2010-10-15

    The purpose of this presentation is to show the obtained results in Cofrentes nuclear power plant (Spain) of control rods Pcc/24 friction test procedure. In order to perform this, a control rod friction test system has been developed. Principally, this system consists on software and data acquisition hardware that obtains and analyzes the control rod pressure variation on which the test is being made. The Pcc/24 procedure objective is to detect an excessive friction in the control rod movement that could cause a control rod drive movement slower than usual. This test is necessary every time that an anomalous alteration is produced in the reactor core that could affect to a fuel rod, and it is executed before the time measure of control rods rapid scram test of the affected rods. This test has to be carried out to all the reactor control rods and takes valuable time during plant refuelling. So, by means of an automatic system to perform the test, we obtain an important time saving during refuelling. On the other hand, the on-line monitoring of the control rod insertion and changes in differential pressure, permits a control rod operation fast and safe validation. Moreover, an automatic individual report of every rod is generated by the system and a final global result report of the entire test developed in refuelling is generated. The mentioned reports can be attached directly to the procedure documents obtaining an office data processing important saving time. (Author)

  5. Extraction of sunflower oil by twin screw extruder: screw configuration and operating condition effects

    Energy Technology Data Exchange (ETDEWEB)

    Kartika, I.A. [FATETA-IPB, Bogor (Indonesia). Department of Agroindustrial Technology; Pontalier, P.Y.; Rigal, L. [Laboratoire de Chimie Agro-Industrielle, UMR 1010 INRA/INP-ENSIACET, Toulouse (France)

    2006-12-15

    The objective of this study was to investigate the screw configuration allowing oil extraction from sunflower seeds with a twin-screw extruder. Experiments were conducted using a co-rotating twin-screw extruder. Five screw profiles were examined to define the best performance (oil extraction yield, specific mechanical energy and oil quality) by studying the influence of operating conditions, barrel temperature, screw speed and feed rate. Generally, the position and spacing between two reversed screw elements affected oil extraction yield. An increase of oil extraction yield was observed as the reversed screw elements were moved with increased spacing between two elements and with smaller pitch elements. In addition, oil extraction yield increased as barrel temperature, screw speed and feed rate were decreased. Highest oil extraction yield (85%) with best cake meal quality (residual oil content lower than 13%) was obtained under operating conditions of 120 {sup o}C, 75 rpm and 19 kg/h. Furthermore, the operating parameters influenced energy input. A decrease in barrel temperature and feed rate followed by an increase in screw speed increased energy input, particularly specific mechanical energy input. Effect of the operating parameters on oil quality was less important. In all experiments tested, the oil quality was very good. The acid value was below 2 mg of KOH/g of oil and total phosphorus content was low, below 100 mg/kg. (author)

  6. The pullout performance of pedicle screws

    CERN Document Server

    Demir, Teyfik

    2015-01-01

    This brief book systematically discusses all subjects that affect the pullout strength of pedicle screws. These screws are used in spinal surgeries to stabilize the spine. The holding strength of the pedicle screw is vital since loosening of the pedicle screws can cause revision surgeries. Once the pedicle screw is pulled out, it is harder to obtain same stabilization for the fused vertebrae. The book reviews the effect of screw designs, application techniques, cement augmentation, coating of the screw and test conditions on the pullout strength. The studies with finite element analysis were also included.

  7. Cutting system for burnable poison rod

    International Nuclear Information System (INIS)

    Shiina, Atsushi; Toyama, Norihide; Koshino, Yasuo; Fujii, Toshio

    1989-01-01

    Burnable poison rods attached to spent fuels are contained in a containing box and transported to a receiving pool. The burnable poison rod-containing box is provisionally situated by the operation to a handling device to a provisional setting rack in a cutting pool and attached to a cutting guide of a cutting device upon cutting. The burnable poison rod is cut only in a cutting pool water and tritium generated upon cutting is dissolved into the cutting pool water. Diffusion of tritium is thus restricted. Further, the cutting pool is isolated by a partition device from the receiving pool during cutting of the burnable poison rod. Accordingly, water in which tritium is dissolved is inhibited from moving to the receiving pool and prevail of tritium contamination can be avoided. (T.M.)

  8. Estimation and control in HTGR fuel rod fabrication

    International Nuclear Information System (INIS)

    Downing, D.J.; Bailey, J.M.

    1980-01-01

    A control algorithm has been derived for an HTGR Fuel Rod Fabrication Process utilizing the method of G.E.P. Box and G.M. Jenkins. The estimator is a Kalman filter and is compared with a Least Square estimator and a standard control chart. The effects of system delays are presented. 1 ref

  9. Development of load calculation techniques on screw and screw press energy consumption

    OpenAIRE

    Татарьянц, Максим Сергеевич; Завинский, Сергей Иванович; Трошин, Алексей Георгиевич

    2015-01-01

    The process of pressing of wood chips in screw machines is researched. It is defined processes taking place in different parts of the screw, formulas allowing to calculate the loads acting on the screw flights, as well as to determine the power required for compression. The unit costs of energy consumption and raw materials in the degree of heat pressing are determined

  10. Monitoring device for withdrawing control rods

    International Nuclear Information System (INIS)

    Higashigawa, Yuichi.

    1985-01-01

    Purpose: To improve the sensitivity and the responsivity to an equivalent extent to those in the case where local power range monitors are densely arranged near each of the control rods, with no actual but pseudo increase of the number of local power range monitors. Constitution: The monitor arrangement is patterned by utilizing the symmetricity of the reactor core and stored in a monitor designating device. The symmetricity of control rods to be selected and withdrawn by an operator is judged by a control rod symmetry monitoring device, while the symmetricity of the withdrawn control rods is judged by a control rod withdrawal state monitoring device. Then, only when both of the devices judge the symmetricity, the control rods are subjected to gang driving by the control rod drive mechanisms. In this way, monitoring at a high sensitivity and responsivity is enabled with no increase for the number of monitors. (Yoshino, Y.)

  11. System and method for consolidating spent fuel rods

    International Nuclear Information System (INIS)

    Baudro, T.O.

    1987-01-01

    A system is described for consolidating spent fuel rods from spent fuel assemblies, comprising: a consolidation container in which the fuel rods may be packed; a frame capable of holding a fuel assembly and the container during consolidation, the frame permitting each of the fuel assembly and the container to be removed; tool means with gripper means for gripping and releasing a rod, the tool means including means for moving the gripper means upwardly and downwardly; a first indexing head having first guide means for guiding the gripper means while the gripper means moves downwardly; a first rail, the first indexing head being slidably mounted on the first rail; a second indexing head having second guide means for guiding the gripper means while the gripper means moves downwardly; a second rail, the second indexing head being slidably mounted on the second rail; and a third rail, the first rail and the second rail being slidably mounted on the third rail; wherein the first indexing head is slidable on the first and third rails to a first position that is above a preselected rod in the fuel assembly; and wherein the second indexing head is slidable on the second and third rails to a second position that is above a preselected location in the container

  12. The Research of Screw Thread Parameter Measurement Based on Position Sensitive Detector and Laser

    International Nuclear Information System (INIS)

    Tong, Q B; Ding, Z L; Chen, J C; Ai, L L; Yuan, F

    2006-01-01

    A technique and system of measuring screw thread parameter based on the theory of laser measurement is presented in this paper, which can be carried out the automated measurement of screw thread parameter. An inspection instrument was designed and produced, which included exterior imaging system of optical path, transverse displacement measurement system, axial displacement measurement system, and a module to deal with, control and assess the data in the upper system. The inspection and estimate of the screw thread contour curve were completed by using position sensitive device (PSD) as photoelectric detector to measure the coordinate data of the screw thread contour curve in the transverse section, and using precise raster to measure the axial displacement of the precision worktable under the screw thread test criterion., computer can gives a measured result according to coordinate data of the screw thread obtained by PSD. The relation between measured spot and image is established, and optimum design of the system organization are introduced, including the image length of receiving lens focal length optical system and the choice of PSD , and some main factor affected measuring precision are analyzed. The experimental results show that the measurement uncertainty of screw thread minor diameter can reach 0. 5μm, which can meet most requests for the measurement of screw thread parameter

  13. Results of automatic system implementation for the friction control rods execution in Cofrentes nuclear power plant

    International Nuclear Information System (INIS)

    Palomo, M.; Urrea, M.; Arnaldos, A.

    2011-01-01

    The purpose of this presentation is to show the obtained results in Cofrentes Nuclear Power Plant (Spain) of Control Rods PCC/24 Friction Test Procedure. In order to perform this, a Control Rod Friction Test System has been developed. Principally, this system consists on software and data acquisition hardware that obtains and analyzes the control rod pressure variation on which the test is being made. The PCC/24 Procedure objective is to detect an excessive friction in the control rod movement that could cause a CRD (Control Rod Drive) movement slower than usual. This test is necessary every time that an anomalous alteration is produced in the reactor core that could affect to a fuel rod, and it is executed before the time measure of control rods rapid scram test of the affected rods. This test has to be carried out to all the reactor control rods and takes valuable time during plant refuelling. So, by means of an automatic system to perform the test, we obtain an important time saving during refuelling. On the other hand, the on-line monitoring of the control rod insertion and changes in differential pressure, permits a control rod operation fast and safe validation. Moreover, an automatic individual report of every rod is generated by the system and a final global result report of the entire test developed in refuelling is generated. The mentioned reports can be attached directly to the procedure documents obtaining an office data processing important saving time.(author)

  14. Results of automatic system implementation for the friction control rods execution in Cofrentes nuclear power plant

    Energy Technology Data Exchange (ETDEWEB)

    Palomo, M., E-mail: mpalomo@iqn.upv.es [Universidad Politecnica de Valencia (UPV) (Spain); Urrea, M., E-mail: matias.urrea@iberdrola.es [Iberdrola Generacion S.A. Valencia (Spain). C.N. Cofrentes; Curiel, M., E-mail: m.curiel@lainsa.com [Logistica y Acondicionamientos Industriales (LAINSA), Valencia (Spain); Arnaldos, A., E-mail: a.arnaldos@titaniast.com [TITANIA Servicios Teconologicos, Valencia (Spain)

    2011-07-01

    The purpose of this presentation is to show the obtained results in Cofrentes Nuclear Power Plant (Spain) of Control Rods PCC/24 Friction Test Procedure. In order to perform this, a Control Rod Friction Test System has been developed. Principally, this system consists on software and data acquisition hardware that obtains and analyzes the control rod pressure variation on which the test is being made. The PCC/24 Procedure objective is to detect an excessive friction in the control rod movement that could cause a CRD (Control Rod Drive) movement slower than usual. This test is necessary every time that an anomalous alteration is produced in the reactor core that could affect to a fuel rod, and it is executed before the time measure of control rods rapid scram test of the affected rods. This test has to be carried out to all the reactor control rods and takes valuable time during plant refuelling. So, by means of an automatic system to perform the test, we obtain an important time saving during refuelling. On the other hand, the on-line monitoring of the control rod insertion and changes in differential pressure, permits a control rod operation fast and safe validation. Moreover, an automatic individual report of every rod is generated by the system and a final global result report of the entire test developed in refuelling is generated. The mentioned reports can be attached directly to the procedure documents obtaining an office data processing important saving time.(author)

  15. A modified transcondylar screw to accommodate anatomical skull base variations.

    Science.gov (United States)

    Ghaly, R F; Lissounov, A

    2017-01-01

    Occipitocervical instability may be attributed to congenital, bony/ligamentous abnormalities, trauma, neoplasm, degenerative bone disease, and failed atlantoaxial fixation. Indications for occipitocervical fixation include the prevention of disabling pain, cranial nerve dysfunction, paralysis, or even sudden death. The screw trajectory for the modified transcondylar screw (mTCS) is optimally planned utilizing a three-dimensional skull reconstructed image. The modified mTCS technique is helpful where there is a loss of bone, such as after prior suboccipital craniotomy and/or an inadequate occipital condyle. The new proposed technique is similar to the classical transcondylar screw placement but follows a deeper course along the bony lip of foramen magnum toward clivus from a dorsolateral approach. The modified mTCS technique allows for direct visualization and, therefore, helps to avoid damage to the hypoglossal nerve and lateral aspect of brain stem.

  16. Freely suspended rod fall dampener, especially for control rod of liquid-cooled nuclear reactor

    International Nuclear Information System (INIS)

    Becvar, J.; Saroch, V.

    1977-01-01

    A shock absorber is described whose advantage is that the space required for the movement of the shock absorber in the operating travel of the system suspension rod-control rod bundle may be reduced. The design allows the automatic disconnection of the system and the removal of the suspension rod from the reactor without dismantling. The braking force reaction is transmitted to the structure above the core. The system fall energy is absorbed on the side of the suspension rod which has a bigger mass. (J.B.)

  17. Control rod position control device

    International Nuclear Information System (INIS)

    Ubukata, Shinji.

    1997-01-01

    The present invention provides a control rod position control device which stores data such as of position signals and driving control rod instruction before and after occurrence of abnormality in control for the control rod position for controlling reactor power and utilized the data effectively for investigating the cause of abnormality. Namely, a plurality of individual control devices have an operation mismatching detection circuit for outputting signals when difference is caused between a driving instruction given to the control rod position control device and the control rod driving means and signals from a detection means for detecting an actual moving amount. A general control device collectively controls the individual control devices. In addition, there is also disposed a position storing circuit for storing position signals at least before and after the occurrence of the control rod operation mismatching. With such procedures, the cause of the abnormality can be determined based on the position signals before and after the occurrence of control rod mismatching operation stored in the position storing circuit. Accordingly, the abnormality cause can be determined to conduct restoration in an early stage. (I.S.)

  18. Analysis of the rod drop accident for Angra-1

    International Nuclear Information System (INIS)

    Veloso, M.A.; Atayde, P.A.

    1989-01-01

    The aim of this work is to present a rod drop accident analysis for the third cycle of the Angra-1 nuclear power plant operating in the automatic control mode. In this analysis all possible configurations for dropped rods caused by a single failure in the controller circuits have been considered. The dropped rod worths, power distributions and excore detector tilts were determined by using the Siemens/KWU neutronic code system, in particular the MEDIUM2, PINPOW and DETILT codes. The transient behaviour of the plant during the rod drop event was simulated with the SACI2/MOD0 code, developed at CDTN. Determinations related to the DNBR design limit were conducted by utilizing the CDTN PANTERA-1P subchannel code. The transient analysis indicated that for dropped rod worths greater than about 425 pcm reactor trip from negative neutron flux rate will take place independently of core conditions. In the range from 0 to 425 pcm large power overshoots may occur as a consequence of the automatic control system action. The magnitude of the maximum power peaking during the event increases with the dropped rod worth, as far as the control bank is able to compensate the initial reactivity decrease. Thermal-hydraulic evaluations carried out with the PANTERA-1P code show that for all the relevant dropped rod worths the minimum DNBR will remain above a limit value of 1.365. Even if this conservative limit is met, the calculated nuclear power peaking factors, F N AH , will be at least 6% higher than the allowable F N AH -values. Therefore, the DNBR design margin will be preserved at the event of rod drop. (author)

  19. 2D and 3D assessment of sustentaculum tali screw fixation with or without Screw Targeting Clamp.

    Science.gov (United States)

    De Boer, A Siebe; Van Lieshout, Esther M M; Vellekoop, Leonie; Knops, Simon P; Kleinrensink, Gert-Jan; Verhofstad, Michael H J

    2017-12-01

    Precise placement of sustentaculum tali screw(s) is essential for restoring anatomy and biomechanical stability of the calcaneus. This can be challenging due to the small target area and presence of neurovascular structures on the medial side. The aim was to evaluate the precision of positioning of the subchondral posterior facet screw and processus anterior calcanei screw with or without a Screw Targeting Clamp. The secondary aim was to evaluate the added value of peroperative 3D imaging over 2D radiographs alone. Twenty Anubifix™ embalmed, human anatomic lower limb specimens were used. A subchondral posterior facet screw and a processus anterior calcanei screw were placed using an extended lateral approach. A senior orthopedic trauma surgeon experienced in calcaneal fracture surgery and a senior resident with limited experience in calcaneal surgery performed screw fixation in five specimens with and in five specimens without the clamp. 2D lateral and axial radiographs and a 3D recording were obtained postoperatively. Anatomical dissection was performed postoperatively as a diagnostic golden standard in order to obtain the factual screw positions. Blinded assessment of quality of fixation was performed by two surgeons. In 2D, eight screws were considered malpositioned when placed with the targeting device versus nine placed freehand. In 3D recordings, two additional screws were malpositioned in each group as compared to the golden standard. As opposed to the senior surgeon, the senior resident seemed to get the best results using the Screw Targeting Clamp (number of malpositioned screws using freehand was eight, and using the targeting clamp five). In nine out of 20 specimens 3D images provided additional information concerning target area and intra-articular placement. Based on the 3D assessment, five additional screws would have required repositioning. Except for one, all screw positions were rated equally after dissection when compared with 3D examinations

  20. Frictional performance of ball screw

    International Nuclear Information System (INIS)

    Nakashima, Katuhiro; Takafuji, Kazuki

    1985-01-01

    As feed screws, ball screws have become to be adopted in place of trapezoidal threads. The structure of ball screws is complex, but those are the indispensable component of NC machine tools and machining centers, and are frequently used for industrial robots. As the problems in the operation of ball screws, there are damage, life and the performance related to friction. As to the damage and life, though there is the problem of the load distribution on balls, the results of the research on rolling bearings are applied. The friction of ball screws consists of the friction of balls and a spiral groove, the friction of a ball and a ball, the friction in a ball-circulating mechanism and the viscous friction of lubricating oil. It was decided to synthetically examine the frictional performance of ball screws, such as driving torque, the variation of driving torque, efficiency, the formation of oil film and so on, under the working condition of wide range, using the screws with different accuracy and the nuts of various circuit number. The experimental setup and the processing of the experimental data, the driving performance of ball screws and so on are reported. (Kako, I.)

  1. Utilization of carbon/carbon composites in nuclear simulation fuel rods

    International Nuclear Information System (INIS)

    Polidoro, H.A.; Otani, S.; Rezende, M.C.; Ferreira, S.R.; Otani, C.

    1988-01-01

    Thermo-hydraulic problems, in nuclear plants are normally analysed by using electrically heated rods. Carbon/carbon composites were used to make heating elements for testing by indirect heating up to a heat flux of 100 W/cm 2 . It is easy to verify that this value can be exceed if the choice of the complementary materials for insulator and cladding were improved. The swaging process used to reduce the cladding diameter prevented the fabrication of graphite heater rods. (author) [pt

  2. Failure Mode and Effects Analysis (FMEA) of the solid state full length rod control system

    International Nuclear Information System (INIS)

    Shopsky, W.E.

    1977-01-01

    The Full Length Rod Control System (FLRCS) controls the power to the rod drive mechanisms for rod movement in response to signals received from the Reactor Control System or from signals generated through Reactor Operator action. Rod movement is used to control reactivity of the reactor during plant operation. The Full Length Rod Control System is designed to perform its reactivity control function in conjunction with the Reactor Control and Protection System, to maintain the reactor core within design safety limits. By the use of a Failure Mode and Effects Analysis, it is shown that the FLRCS will perform its reactivity control functions considering the loss of single active components. That is, sufficient fault limiting control circuits are provided which blocks control rod movement and/or indicates presence of a fault condition at the Control Board. Reactor operator action or automatic reactor trip will thus mitigate the consequences of potential failure of the FLRCS. The analysis also qualitatively demonstrates the reliability of the FLRCS to perform its intended function

  3. Kinematics of Planetary Roller Screw Mechanism considering Helical Directions of Screw and Roller Threads

    Directory of Open Access Journals (Sweden)

    Shangjun Ma

    2015-01-01

    Full Text Available Based on the differential principle of thread transmission, an analytical model considering helical directions between screw and roller threads in planetary roller screw mechanism (PRSM is presented in this work. The model is critical for the design of PRSM with a smaller lead and a bigger pitch to realize a higher transmission accuracy. The kinematic principle of planetary transmission is employed to analyze the PRSM with different screw thread and roller thread directions. In order to investigate the differences with different screw thread and roller thread directions, the numerical model is developed by using the software Adams to validate the analytical solutions calculated by the presented model. The results indicate, when the helical direction of screw thread is identical with the direction of roller thread, that the lead of PRSM is unaffected regardless of whether sliding between screw and rollers occurs or not. Only when the direction of screw thread is reverse to the direction of roller thread, the design of PRSM with a smaller lead can be realized under a bigger pitch. The presented models and numerical simulation method can be used to research the transmission accuracy of PRSM.

  4. Preliminary design report for the prototypical fuel rod consolidation system

    International Nuclear Information System (INIS)

    Rosa, J.M.

    1986-01-01

    This report documents NUTECH's preliminary design of a dry, spent fuel rod consolidation system. This preliminary design is the result of Phase I of a planned four phase project. The present report on this project provides a considerable amount of detail for a preliminary design effort. The design and all of its details are described in this Preliminary Design Report (PDR). The NUTECH dry rod consolidation system described herein is remotely operated. It provides for automatic operation, but with operator hold points between key steps in the process. The operator has the ability to switch to a manual operation mode at any point in the process. The system is directed by the operator using an executive computer which controls and coordinates the operation of the in-cell equipment. The operator monitors the process using an in-cell closed circuit television (CCTV) system with audio output and equipment status displays on the computer monitor. The in-cell mechanical equipment consists of the following: (1) two overhead cranes with manipulators; (2) a multi-degree of freedom fuel handling table and its clamping equipment; (3) a fuel assembly end fitting removal station and its tools; (4) a consolidator (which pulls rods, assembles the consolidated bundle and loads the canister); (5) a canister end cap welder and weld inspection system; (6) decontamination systems; and (7) the CCTV and microphone systems

  5. Performance Testing of Jefferson Lab 12 GeV Helium Screw Compressors

    Science.gov (United States)

    Knudsen, P.; Ganni, V.; Dixon, K.; Norton, R.; Creel, J.

    2015-08-01

    Oil injected screw compressors have essentially superseded all other types of compressors in modern helium refrigeration systems due to their large displacement capacity, reliability, minimal vibration, and capability of handling helium's high heat of compression. At the present state of compressor system designs for helium refrigeration systems, typically two-thirds of the lost input power is due to the compression system. It is important to understand the isothermal and volumetric efficiencies of these machines to help properly design the compression system to match the refrigeration process. It is also important to identify those primary compressor skid exergetic loss mechanisms which may be reduced, thereby offering the possibility of significantly reducing the input power to helium refrigeration processes which are extremely energy intensive. This paper summarizes the results collected during the commissioning of the new compressor system for Jefferson Lab's (JLab's) 12 GeV upgrade. The compressor skid packages were designed by JLab and built to print by industry. They incorporate a number of modifications not typical of helium screw compressor packages and most importantly allow a very wide range of operation so that JLab's patented Floating Pressure Process can be fully utilized. This paper also summarizes key features of the skid design that allow this process and facilitate the maintenance and reliability of these helium compressor systems.

  6. Fault tolerant, multiplexed control rod position detection and indication system for nuclear power plants

    International Nuclear Information System (INIS)

    Dufek, W.L.; Jelovich, J.J.; Neuner, J.A.

    1977-01-01

    The majority of Westinghouse nuclear plants placed in service thus far have incorporated a Rod Position Indication system based upon an analog design philosophy. This system, while meeting all functional and accuracy requirements, has proven somewhat cumbersome, particularly in the area of initial field calibration and maintenance. This paper describes a new Digital Rod Position Indication system (DRPI) developed for use with pressurized water reactors. The system is based upon a digital design philosophy and meets all previous design constraints and environmental requirements. Further, fault tolerance, improved accuracy, interference from adjacent rods and the elimination of adjustments and calibration has been provided

  7. A locking compression plate versus the gold-standard non-locking plate with lag screw for first metatarsophalangeal fusion: A biomechanical comparison.

    Science.gov (United States)

    Mandell, Daniel; Karbassi, John; Zhou, Hanbing; Burroughs, Brian; Aurigemma, Philip; Patel, Abhay R

    2018-03-01

    The treatment of end-stage first metatarso-phalangeal joint (MTP) arthritis has been arthrodesis. A dorsal non-locking plate with a lag screw has been the standard traditional fixation method. This study compares the biomechanical strength of a locking compression plate (LCP) with and without internal compression versus this known gold standard. In group 1, six matched pairs of cadaver great toes were used to compare the standard non-locking dorsal plate and 3.5mm lag screw to an anatomic locking compression plate in which a lag screw was utilized rather than the internal compression features of the plate. In group 2, another six matched pairs of cadaver great toes were used to compare the gold standard to the locking compression plate, utilizing the plate's internal compression feature instead of a lag screw. A material testing system (MTS) machine applied loads to the MTP joints and measured displacement and stiffness of the constructs. The stiffness of the constructs (Young's modulus) was calculated from the force-displacement curves, and the displacement was measured. The locking compression plate group that used the compression features of the plate, without the lag screw, had less joint displacement and higher stiffness than control (p<0.05). The same plating construct in which a lag screw was used rather than internal compression of the plate was found to be stiffer than the control (p<0.05), but displacement was not statistically significant. The results suggest that a locking compression plate alone provides the stiffest construct for a first MTP joint fusion. Copyright © 2017 Elsevier Ltd. All rights reserved.

  8. A New Electromagnetic Navigation System for Pedicle Screws Placement: A Human Cadaver Study at the Lumbar Spine.

    Directory of Open Access Journals (Sweden)

    Patrick Hahn

    Full Text Available Technical developments for improving the safety and accuracy of pedicle screw placement play an increasingly important role in spine surgery. In addition to the standard techniques of free-hand placement and fluoroscopic navigation, the rate of complications is reduced by 3D fluoroscopy, cone-beam CT, intraoperative CT/MRI, and various other navigation techniques. Another important aspect that should be emphasized is the reduction of intraoperative radiation exposure for personnel and patient. The aim of this study was to investigate the accuracy of a new navigation system for the spine based on an electromagnetic field.Twenty pedicle screws were placed in the lumbar spine of human cadavers using EMF navigation. Navigation was based on data from a preoperative thin-slice CT scan. The cadavers were positioned on a special field generator and the system was matched using a patient tracker on the spinous process. Navigation was conducted using especially developed instruments that can be tracked in the electromagnetic field. Another thin-slice CT scan was made postoperatively to assess the result. The evaluation included the position of the screws in the direction of trajectory and any injury to the surrounding cortical bone. The results were classified in 5 groups: grade 1: ideal screw position in the center of the pedicle with no cortical bone injury; grade 2: acceptable screw position, cortical bone injury with cortical penetration ≤ 2 mm; grade 3: cortical bone injury with cortical penetration 2,1-4 mm, grad 4: cortical bone injury with cortical penetration 4,1-6 mm, grade 5: cortical bone injury with cortical penetration >6 mm.The initial evaluation of the system showed good accuracy for the lumbar spine (65% grade 1, 20% grade 2, 15% grade 3, 0% grade 4, 0% grade 5. A comparison of the initial results with other navigation techniques in literature (CT navigation, 2D fluoroscopic navigation shows that the accuracy of this system is

  9. Burnable poison rod

    International Nuclear Information System (INIS)

    Natsume, Tomohiro.

    1988-01-01

    Purpose: To increase the reactor core lifetime by decreasing the effect of neutron absorption of burnable poison rods by using material with less neutron absorbing effect. Constitution: Stainless steels used so far as the coating material for burnable poison rods have relatively great absorption in the thermal neutral region and are not preferred in view of the neutron economy. Burnable poison rods having fuel can made of zirconium alloy shows absorption the thermal neutron region lower by one digit than that of stainless steels but they shows absorption in the resonance region and the cost is higher. In view of the above, the fuel can of the burnable poison material is made of aluminum or aluminu alloy. This can reduce the neutron absorbing effect by stainless steel fuel can and effectively utilize neutrons that have been wastefully absorbed and consumed in stainless steels. (Takahashi, M.)

  10. Modeling and Analyzing the Slipping of the Ball Screw

    Directory of Open Access Journals (Sweden)

    Nannan Xu

    Full Text Available AbstractThis paper aims to set up the ball systematic slipping model and analyze the slipping characteristics caused by different factors for a ball screw operating at high speeds. To investigate the ball screw slipping mechanism, transformed coordinate system should be established firstly. Then it is used to set up mathematical modeling for the ball slipping caused by the three main reasons and the speed of slipping can be calculated. Later, the influence of the contact angle, helix angle and screw diameter for ball screw slipping will be analyzed according to the ball slipping model and slipping speeds equation and the slipping analysis will be obtained. Finally, curve of slipping analysis and that of mechanical efficiency of the ball screw analysis by Lin are compared, which will indirectly verify the correctness of the slipping model. The slipping model and the curve of slipping analysis established in this paper will provide theory basis for reducing slipping and improving the mechanical efficiency of a ball screw operating at high speeds.

  11. Design, construction and simulation of a multipurpose system for precision movement of control rods in nuclear reactors

    Energy Technology Data Exchange (ETDEWEB)

    Shirazi, S.A. Mousavi, E-mail: a_moosavi@azad.ac.i [Department of Physics, Islamic Azad University, South Tehran Branch, Tehran (Iran, Islamic Republic of); Aghanajafi, C. [Department of Mechanical Engineering, K.N.T. University of Technology, Tehran (Iran, Islamic Republic of); Sadoughi, S. [Department of Electrical Engineering, Sharif University of Technology, Tehran (Iran, Islamic Republic of); Sharifloo, N. [Department of Physics, Imam Hossein University, Tehran (Iran, Islamic Republic of)

    2010-12-15

    This article presents the design and implementation of a microcontroller-based system for the automatic movement of control rods in nuclear reactors of either power or research types. This system is controlled automatically, is linked to a personal computer system, and has manual controlling ability as well. The important features of this system are: automatic scram of the control rods, activation of alarm in emergency situations, and the ability to tune the control rod movement course both upwards and downwards. In this system, a small tank has been improvised as a coolant reservoir for pool type reactors such as Tehran Research Reactor and its water level is continuously adjusted by special sensors. Also, this system can be applied for controlling various types of control rods such as the regulating rods, safety rods and shim rods; can be connected to all reactor measurement tools and systems such as the period meter, power meter and flux meter; and can receive feedback signals from them. The devised system can be calibrated with these measurement tools by two special potentiometers in the related electronic board. The processes of this system have been simulated by the SIMULINK tool kit of MATLAB software and all responses of the system, including oscillation and transient responses, have been analyzed.

  12. Nondestructive assay of HTGR fuel rods

    International Nuclear Information System (INIS)

    Menlove, H.O.

    1974-01-01

    Performance characteristics of three different radioactive source NDA systems are compared for the assay of HTGR fuel rods and stacks of rods. These systems include the fast neutron Sb-Be assay system, the 252 Cf ''Shuffler,'' and the thermal neutron PAPAS assay system. Studies have been made to determinethe perturbation on the measurements from particle size, kernel Th/U ratio, thorium content, and hydrogen content. In addition to the total 235 U determination, the pellet-to-pellet or rod-to-rod uniformity of HTGR fuel rod stacks has been measured by counting the delayed gamma rays with a NaI through-hole in the PAPAS system. These measurements showed that rod substitutions can be detected easily in a fuel stack, and that detailed information is available on the loading variations in a uniform stack. Using a 1.0 mg 252 Cf source, assay rates of 2 to 4 rods/s are possible, thus facilitating measurement of 100 percent of a plant's throughput. (U.S.)

  13. Loosening torque of Universal Abutment screws after cyclic loading: influence of tightening technique and screw coating.

    Science.gov (United States)

    Bacchi, Atais; Regalin, Alexandre; Bhering, Claudia Lopes Brilhante; Alessandretti, Rodrigo; Spazzin, Aloisio Oro

    2015-10-01

    The purpose of this study was to evaluate the influence of tightening technique and the screw coating on the loosening torque of screws used for Universal Abutment fixation after cyclic loading. Forty implants (Titamax Ti Cortical, HE, Neodent) (n=10) were submerged in acrylic resin and four tightening techniques for Universal Abutment fixation were evaluated: A - torque with 32 Ncm (control); B - torque with 32 Ncm holding the torque meter for 20 seconds; C - torque with 32 Ncm and retorque after 10 minutes; D - torque (32 Ncm) holding the torque meter for 20 seconds and retorque after 10 minutes as initially. Samples were divided into subgroups according to the screw used: conventional titanium screw or diamond like carbon-coated (DLC) screw. Metallic crowns were fabricated for each abutment. Samples were submitted to cyclic loading at 10(6) cycles and 130 N of force. Data were analyzed by two-way ANOVA and Tukey's test (5%). The tightening technique did not show significant influence on the loosening torque of screws (P=.509). Conventional titanium screws showed significant higher loosening torque values than DLC (P=.000). The use of conventional titanium screw is more important than the tightening techniques employed in this study to provide long-term stability to Universal Abutment screws.

  14. Ensaios mecânicos de um sistema de fixação pedicular com barra transversal Mechanical assay of a pedicular fixation system with transversal rod

    Directory of Open Access Journals (Sweden)

    Helton Luiz Aparecido Defino

    2001-12-01

    Full Text Available Foi realizado estudo biomecânico de um protótipo de sistema de fixação vertebral que utiliza o pedículo vertebral como ponto de ancoragem dos implantes, associado a hastes que conectam transversalmente os parafusos pediculares. De modo diferente dos sistemas convencionais, nos quais os parafusos são conectados no sentido longitudinal, no sistema desenvolvido as hastes são conectadas transversalmente aos parafusos. Foram realizados ensaios mecânicos (flexo-compressão, flexão lateral e torção utilizando-se corpos de prova de madeira em máquina universal de testes, com a finalidade de comparar a resistência desse sistema de fixação com o sistema convencionalmente utilizado. Os testes biomecânicos mostraram que o sistema desenvolvido apresentou menor resistência nos ensaios mecânicos realizados, quando comparado com o sistema de fixação convencional.A biomechanical study of a spine fixation prototype was performed. This system uses vertebral pedicle as anchor point of the implants in association with transversally connecting rods. This is different form the usual systems where longitudinally placed rods connect the pedicular screws. Mechanical assays were performed (flexo-compression, lateral flexion, torsion using probe wood pieces in an universal testing machine, aiming to compare the resistance of this system of fixation to the conventionally used ones. Biomechanical tests showed that the system was less resistant to the mechanical assays when compared to conventional systems.

  15. Sacroiliac Screw Fixation

    NARCIS (Netherlands)

    E.W. van den Bosch

    2003-01-01

    textabstractThe aim of this thesis is to evaluate three major aspects of the use of sacroiliac screws in patients with unstable pelvic ring fractures: the optimal technique for sacroiliac screw fixation, the reliability of peroperative fluoroscopy and the late results. We focused on the questions

  16. Development of three methods for control rod position monitoring based on fixed in-core neutron detectors

    International Nuclear Information System (INIS)

    Peng, Xingjie; Li, Qing; Wang, Kan

    2015-01-01

    Highlights: • Three methods are utilized separately to unfold the control rod position from the fixed in-core neutron detector measurements. • Fixed in-core neutron detector measurements are simulated by neutronics code SMART. • Numerical results show that all these methods can unfold the control rod position accurately. • Two correction strategies are proposed to correct the simulated fixed in-core detector signals. - Abstract: Nuclear reactor core power distribution on-line monitoring system is very important in core surveillance, and this system should have the ability to indicate some abnormal conditions, such as the unacceptable control rod misalignment. In this study, the methodologies of radial basis function neural network (RBFNN), group method of data handling (GMDH) and Levenberg–Marquardt (LM) algorithm are utilized separately to unfold the control rod position from the fixed in-core neutron detector measurements. For using these methods, a large number of in-core detector signals corresponding to various known rod positions are needed. These data can be generated by an advanced core calculation code. In this study, the neutronics code SMART was used. The simulation results show that all these methods can unfold the control rod position accurately, and the performance comparison shows that the regularized RBFNN performs best. Two correction strategies are proposed to correct the simulated fixed in-core detector signals and improve the rod position monitoring accuracy when there are mismatches between actual physical factors and modeled physical factors

  17. The flying buttress construct for posterior spinopelvic fixation: a technical note

    Directory of Open Access Journals (Sweden)

    van Ooij Bas

    2011-04-01

    Full Text Available Abstract Background Posterior fusion of the spine to the pelvis in paediatric and adult spinal deformity is still challenging. Especially assembling of the posterior rod construct to the iliac screw is considered technically difficult. A variety of spinopelvic fixation techniques have been developed. However, extreme bending of the longitudinal rods or the use of 90-degree lateral offset connectors proved to be difficult, because the angle between the rod and the iliac screw varies from patient to patient. Methods We adopted a new spinopelvic fixation system, in which iliac screws are side-to-side connected to the posterior thoracolumbar rod construct, independent of the angle between the rod and the iliac screw. Open angled parallel connectors are used to connect short iliac rods from the posterior rod construct to the iliac screws at both sides. The construct resembles in form and function an architectural Flying Buttress, or lateral support arches, used in Gothic cathedrals. Results and discussion Three different cases that illustrate the Flying Buttress construct for spinopelvic fixation are reported here with the clinical details, radiographic findings and surgical technique used. Conclusion The Flying Buttress construct may offer an alternative surgical option for spinopelvic fixation in circumstances wherein coronal or sagittal balance cannot be achieved, for example in cases with significant residual pelvic obliquity, or in revision spinal surgery for failed lumbosacral fusion.

  18. The flying buttress construct for posterior spinopelvic fixation: a technical note

    Science.gov (United States)

    2011-01-01

    Background Posterior fusion of the spine to the pelvis in paediatric and adult spinal deformity is still challenging. Especially assembling of the posterior rod construct to the iliac screw is considered technically difficult. A variety of spinopelvic fixation techniques have been developed. However, extreme bending of the longitudinal rods or the use of 90-degree lateral offset connectors proved to be difficult, because the angle between the rod and the iliac screw varies from patient to patient. Methods We adopted a new spinopelvic fixation system, in which iliac screws are side-to-side connected to the posterior thoracolumbar rod construct, independent of the angle between the rod and the iliac screw. Open angled parallel connectors are used to connect short iliac rods from the posterior rod construct to the iliac screws at both sides. The construct resembles in form and function an architectural Flying Buttress, or lateral support arches, used in Gothic cathedrals. Results and discussion Three different cases that illustrate the Flying Buttress construct for spinopelvic fixation are reported here with the clinical details, radiographic findings and surgical technique used. Conclusion The Flying Buttress construct may offer an alternative surgical option for spinopelvic fixation in circumstances wherein coronal or sagittal balance cannot be achieved, for example in cases with significant residual pelvic obliquity, or in revision spinal surgery for failed lumbosacral fusion. PMID:21489256

  19. A cold mass support system based on the use of oriented fiberglass epoxy rods in bending

    International Nuclear Information System (INIS)

    Green, Michael A.; Corradi, Carol A.; LaMantia, Roberto F.; Zbasnik, Jon P.

    2002-01-01

    This report describes a cold mass support system that uses oriented fiberglass epoxy (other low heat leak oriented fiber material can also be used) rods. In the direction of the rods, where forces are carried in tension or compression, the support system is very stiff. In the other directions, the rods are subjected to bending stresses. When the support rods are put in bending the cold mass support is quite compliant. This type of support system can be used in situation where space for a cold mass support system is limited and where compliance can be tolerated in at least one direction. Break test data for 15.9-mm and 19.1-mm diameter oriented fiberglass rods is presented in this report. The cold mass supports for the DFBX distribution boxes are presented as an example of this type of cold mass support system

  20. The safety feature of hydraulic driving system of control rod for 200 MW nuclear heating reactor

    International Nuclear Information System (INIS)

    Chi Zongbo; Wu Yuanqiang

    1997-01-01

    The hydraulic driving system of control rod is used as control rod drive mechanism in 200 MW nuclear heating reactor. Design of this system is based on passive system, integrating drive and guide of control rod. The author analyzes the inherent safety and the design safety of this system, with mechanism of control rod not ejecting when the pressure of pressure vessel is lost, and calculating result of core not exposing when the amount of coolant is drained by broken pipe. The results indicate that this system has good safety feature, and assures reactor safety under any accident conditions, providing important technology support for 200 MW nuclear heating reactor with inherent safety feature

  1. Summary of the fuel rod support system (grids) design for LWBR (LWBR development program)

    International Nuclear Information System (INIS)

    Richardson, K.D.

    1979-02-01

    Design features of the fuel rod support system (grids) for the Light Water Breeder Reactor (LWBR) installed in the Shippingport Atomic Power Station, Shippingport, Pennsylvania, are described. The grids are fabricated from AM-350 stainless steel and provide lateral support of the fuel rods in the three regions (seed, blanket, and reflector) of the reactor. A comparison is made of the LWBR grids, whose cells are arranged in triangular-pitched arrays, with rod support systems employed in commercial light water reactors

  2. Precise placement of lag screws in operative treatment of trochanteric femoral fractures with a new guide system.

    Science.gov (United States)

    Poyanli, Oguz S; Soylemez, Salih; Ozkut, Afsar T; Uygur, Esat; Kemah, Bahattin; Unal, Omer K

    2015-11-01

    We assessed the accuracy of a new guide system that we developed to place lag screws in the proper position with the minimum number of attempts for operative treatment of trochanteric femoral fractures. A total of 55 consecutive trochanteric femoral fractures were treated with a cephalomedullary nail. The first 27 consecutive patients were treated with the standard operation (group A), while the new guide system was used in the last 28 consecutive patients (group B). The numbers of attempts to place K wires and the duration of surgery were noted. Accuracy of lag screw placement was evaluated by measuring the angle of deviation from the central axis of the femoral head. Deviation values ranged from -11̊ to +15̊ for the 27 cases in group A, with a median absolute deviation of 8̊±6̊. That in the 28 cases after the introduction of the new guide system (group B) ranged from -5̊ to +6̊, with a median absolute deviation of 0.5̊±3̊ (Pfractures. The present study indicated that this new guide system and nail facilitate accurate placement of lag screws in the appropriate position with the minimum number of attempts. Copyright © 2015 Elsevier Ltd. All rights reserved.

  3. Complications of syndesmotic screw removal

    NARCIS (Netherlands)

    Schepers, Tim; van Lieshout, Esther M. M.; de Vries, Mark R.; van der Elst, Maarten

    2011-01-01

    Currently, the metallic syndesmotic screw is the gold standard in the treatment of syndesmotic disruption. Whether or not this screw needs to be removed remains debatable. The aim of the current study was to determine the complications which occur following routine removal of the syndesmotic screw

  4. Intraoperative implant rod three-dimensional geometry measured by dual camera system during scoliosis surgery.

    Science.gov (United States)

    Salmingo, Remel Alingalan; Tadano, Shigeru; Abe, Yuichiro; Ito, Manabu

    2016-05-12

    Treatment for severe scoliosis is usually attained when the scoliotic spine is deformed and fixed by implant rods. Investigation of the intraoperative changes of implant rod shape in three-dimensions is necessary to understand the biomechanics of scoliosis correction, establish consensus of the treatment, and achieve the optimal outcome. The objective of this study was to measure the intraoperative three-dimensional geometry and deformation of implant rod during scoliosis corrective surgery.A pair of images was obtained intraoperatively by the dual camera system before rotation and after rotation of rods during scoliosis surgery. The three-dimensional implant rod geometry before implantation was measured directly by the surgeon and after surgery using a CT scanner. The images of rods were reconstructed in three-dimensions using quintic polynomial functions. The implant rod deformation was evaluated using the angle between the two three-dimensional tangent vectors measured at the ends of the implant rod.The implant rods at the concave side were significantly deformed during surgery. The highest rod deformation was found after the rotation of rods. The implant curvature regained after the surgical treatment.Careful intraoperative rod maneuver is important to achieve a safe clinical outcome because the intraoperative forces could be higher than the postoperative forces. Continuous scoliosis correction was observed as indicated by the regain of the implant rod curvature after surgery.

  5. Intraoperative insertion torque of lumbar pedicle screw and postoperative radiographic evaluation. Short-term observation

    International Nuclear Information System (INIS)

    Mizuno, Koichi; Shinomiya, Kenichi; Otani, Kazuyuki

    2005-01-01

    The correlation between the insertion torque of a lumbar pedicle screw and the mechanical stability of the screw in the bone has been mentioned in in vitro studies. The purpose of this study was to confirm the factors affecting the insertion torque of such screws in vivo. Also, the contribution of insertion torque to the initial stability of the fusion area was to be analyzed in vivo. A series of 23 cases representing 50 lumbar vertebrae were included in this study, in which we examined bone mineral density using quantitative computed tomography (CT) prior to operation. Two screw shapes were utilized, with the insertion torque for each screw measured at two points in time. The correlation between insertion torque and mineral density was investigated. Screw positions were confirmed on postoperative CT scans, and the effect of the screw thread cutting into the cortex bone was investigated. Radiographic changes at three points during a period of 3 months were also measured, and we then evaluated the interrelations between these changes and insertion torque. Furthermore, the relation between insertion torque and instability at 3 months was investigated. Correlations of insertion torque and bone mineral density depended on screw shape. There was no correlation found with mineral density in the case of cylindrical screws. Insertion torque was not affected by the screw thread cutting into the cortex of bone. As for postoperative alignment changes, no definitive trends could be ascertained, and no interrelations with torque and alignment changes were observed. There is a possibility that insertion torque was related to early-stage stability, but no statistical relation could be determined. (author)

  6. Twin Screw Extruders as Continuous Mixers for Thermal Processing: a Technical and Historical Perspective.

    Science.gov (United States)

    Martin, Charlie

    2016-02-01

    Developed approximately 100 years ago for natural rubber/plastics applications, processes via twin screw extrusion (TSE) now generate some of the most cutting-edge drug delivery systems available. After 25 or so years of usage in pharmaceutical environments, it has become evident why TSE processing offers significant advantages as compared to other manufacturing techniques. The well-characterized nature of the TSE process lends itself to ease of scale-up and process optimization while also affording the benefits of continuous manufacturing. Interestingly, the evolution of twin screw extrusion for pharmaceutical products has followed a similar path as previously trodden by plastics processing pioneers. Almost every plastic has been processed at some stage in the manufacturing train on a twin screw extruder, which is utilized to mix materials together to impart desired properties into a final part. The evolution of processing via TSEs since the early/mid 1900s is recounted for plastics and also for pharmaceuticals from the late 1980s until today. The similarities are apparent. The basic theory and development of continuous mixing via corotating and counterrotating TSEs for plastics and drug is also described. The similarities between plastics and pharmaceutical applications are striking. The superior mixing characteristics inherent with a TSE have allowed this device to dominate other continuous mixers and spurred intensive development efforts and experimentation that spawned highly engineered formulations for the commodity and high-tech plastic products we use every day. Today, twin screw extrusion is a battle hardened, well-proven, manufacturing process that has been validated in 24-h/day industrial settings. The same thing is happening today with new extrusion technologies being applied to advanced drug delivery systems to facilitate commodity, targeted, and alternative delivery systems. It seems that the "extrusion evolution" will continue for wide

  7. Positioning of pedicle screws in adolescent idiopathic scoliosis using electromyography

    Directory of Open Access Journals (Sweden)

    Bruno Moreira Gavassi

    2015-06-01

    Full Text Available OBJECTIVE: To analyze the occurrence of poor positioning of pedicle screws inserted with the aid of intraoperative electromyographic stimulation in the treatment of Adolescent Idiopathic Scoliosis (AIS.METHODS: This is a prospective observational study including all patients undergoing surgical treatment for AIS, between March and December 2013 at a single institution. All procedures were monitored by electromyography of the inserted pedicle screws. The position of the screws was evaluated by assessment of postoperative CT and classified according to the specific AIS classification system.RESULTS: Sixteen patients were included in the study, totalizing 281 instrumented pedicles (17.5 per patient. No patient had any neurological deficit or complaint after surgery. In the axial plane, 195 screws were found in ideal position (69.4% while in the sagittal plane, 226 screws were found in ideal position (80.4%. Considering both the axial and the sagittal planes, it was observed that 59.1% (166/281 of the screws did not violate any cortical wall.CONCLUSION: The use of pedicle screws proved to be a safe technique without causing neurological damage in AIS surgeries, even with the occurrence of poor positioning of some implants.

  8. Correlation analysis between change in thoracic kyphosis and multilevel facetectomy and screw density in main thoracic adolescent idiopathic scoliosis surgery.

    Science.gov (United States)

    Sudo, Hideki; Abe, Yuichiro; Kokabu, Terufumi; Ito, Manabu; Abumi, Kuniyoshi; Ito, Yoichi M; Iwasaki, Norimasa

    2016-09-01

    Controversy exists regarding the effects of multilevel facetectomy and screw density on deformity correction, especially thoracic kyphosis (TK) restoration in adolescent idiopathic scoliosis (AIS) surgery. This study aimed to evaluate the effects of multilevel facetectomy and screw density on sagittal plane correction in patients with main thoracic (MT) AIS curve. A retrospective correlation and comparative analysis of prospectively collected, consecutive, non-randomized series of patients at a single institution was undertaken. Sixty-four consecutive patients with Lenke type 1 AIS treated with posterior correction and fusion surgery using simultaneous double-rod rotation technique were included. Patient demographics and preoperative and 2-year postoperative radiographic measurements were the outcome measures for this study. Multiple stepwise linear regression analysis was conducted between change in TK (T5-T12) and the following factors: age at surgery, Risser sign, number of facetectomy level, screw density, preoperative main thoracic curve, flexibility in main thoracic curve, coronal correction rate, preoperative TK, and preoperative lumbar lordosis. Patients were classified into two groups: TKcorrect hypokyphosis. Copyright © 2016 Elsevier Inc. All rights reserved.

  9. Scaphoid Fracture Fixation with an Acutrak? Screw

    OpenAIRE

    Loving, Vilert A.; Richardson, Michael L.

    2015-01-01

    We report a case of fixation of a scaphoid fracture using an Acutrak? screw. This screw is cannulated and headless, which allows it to be implanted below the surface of the bone. It uses the same concept of variable thread pitch as the Herbert screw, but unlike the Herbert screw, is fully threaded, with continuously varying pitch along its length. This variable pitch creates constant compression across a fracture as the screw is advanced, and gives the screw its unique appearance. This featur...

  10. Mechanical comparison between lengthened and short sacroiliac screws in sacral fracture fixation: a finite element analysis.

    Science.gov (United States)

    Zhao, Y; Zhang, S; Sun, T; Wang, D; Lian, W; Tan, J; Zou, D; Zhao, Y

    2013-09-01

    To compare the stability of lengthened sacroiliac screw and standard sacroiliac screw for the treatment of unilateral vertical sacral fractures; to provide reference for clinical applications. A finite element model of Tile type C pelvic ring injury (unilateral Denis type II fracture of the sacrum) was produced. The unilateral sacral fractures were fixed with lengthened sacroiliac screw and sacroiliac screw in six different types of models respectively. The translation and angle displacement of the superior surface of the sacrum (in standing position on both feet) were measured and compared. The stability of one lengthened sacroiliac screw fixation in S1 or S2 segment is superior to that of one sacroiliac screw fixation in the same sacral segment. The stability of one lengthened sacroiliac screw fixation in S1 and S2 segments respectively is superior to that of one sacroiliac screw fixation in S1 and S2 segments respectively. The stability of one lengthened sacroiliac screw fixation in S1 and S2 segments respectively is superior to that of one lengthened sacroiliac screw fixation in S1 or S2 segment. The stability of one sacroiliac screw fixation in S1 and S2 segments respectively is markedly superior to that of one sacroiliac screw fixation in S1 or S2 segment. The vertical and rotational stability of lengthened sacroiliac screw fixation and sacroiliac screw fixation in S2 is superior to that of S1. In a finite element model of type C pelvic ring disruption, S1 and S2 lengthened sacroiliac screws should be utilized for the fixation as regularly as possible and the most stable fixation is the combination of the lengthened sacroiliac screws of S1 and S2 segments. Even if lengthened sacroiliac screws cannot be systematically used due to specific conditions, one sacroiliac screw fixation in S1 and S2 segments respectively is recommended. No matter which kind of sacroiliac screw is used, if only one screw can be implanted, the fixation in S2 segment is more recommended

  11. In vitro evaluation of force-expansion characteristics in a newly designed orthodontic expansion screw compared to conventional screws

    Directory of Open Access Journals (Sweden)

    Oshagh Morteza

    2009-01-01

    Full Text Available Objective : Expansion screws like Hyrax, Haas and other types, produce heavy interrupted forces which are unfavorable for dental movement and could be harmful to the tooth and periodontium. The other disadvantage of these screws is the need for patient cooperation for their regular activation. The purpose of this study was to design a screw and compare its force- expansion curve with other types. Materials and Methods : A new screw was designed and fabricated in the same dimension, with conventional types, with the ability of 8 mm expansion (Free wire length: 12 mm, initial compression: 4.5 mm, spring wire diameter: 0.4 mm, spring diameter: 3 mm, number of the coils: n0 ine, material: s0 tainless steel. In this in vitro study, the new screw was placed in an acrylic orthodontic appliance, and after mounting on a stone cast, the force-expansion curve was evaluated by a compression test machine and compared to other screws. Results : Force-expansion curve of designed screw had a flatter inclination compared to other screws. Generally it produced a light continuous force (two to 3.5 pounds for every 4 mm of expansion. Conclusion : In comparison with heavy and interrupted forces of other screws, the newly designed screw created light and continuous forces.

  12. Making effective use of rod pumping systems in coalbed methane applications

    Energy Technology Data Exchange (ETDEWEB)

    Crivello, A. [eProduction Solutions Inc., Kingwood, TX (United States)

    2003-07-01

    The advantages of optimizing coalbed methane (CBM) operations are increased production, reduced expenses, improved efficiency, and better inventory. The author discussed the CBM production cycle and the possible artificial lift options, including electric submersible pump (ESP), plunger lift, primary coolant pump (PCP), and reciprocating rod lift. The presentation focused on the rod lift, as it represents a low to moderate capital expenditure, has good system efficiency, an excellent fluid volume range, an excellent salvage value, excellent familiarity with equipment, and has readily available parts and service. The major disadvantage of the rod lift is that the fixed operating range does not adapt to changing reservoir characteristics. A comparison between the rod pump controller and the variable speed drive was presented. The well can be operated at or near the pumped off condition with variable speed drives with rod pumping intelligence. The author provided a closer examination of the variable frequency drive and the vector flux drive. The presentation also included a discussion of prime movers, drive and inclinometer, gearbox loading, rod load limiter, and dynamometer cards. Three case studies were presented: CSW1, CSW2, and CSW3. It was concluded that wells must be kept pumping, and that a Flux Vector Drive should be used along with an NEMA B motor and properly sized pumping unit and pump. tabs., figs.

  13. Study on anti-seismic test of control rod driving system suspended by magnetic force

    International Nuclear Information System (INIS)

    Zhang Zhihua; Qian Dazhi; Xu Xianqi; Huang Hongwen; Zhang Zhengming; Wu Xinxin; Hu Xiao

    2012-01-01

    To verify the stability, reliability and security function in extreme conditions, the anti-seismic test of control rod drive line was conducted. Drop-time of control rod drive line in different earthquake intensities was got. The response and strain values of control rod drive line acceleration on SL-1, SL-2 level were measured. Safety functions of control rod drive line were validated in different work conditions. Anti-seismic test data shows that the driving system can keep the structure's integrality and realize operation function under OBE and SSE. (authors)

  14. Experimental Study of Hydraulic Control Rod Drive Mechanism for Passive IN-core Cooling System of Nuclear Power Plant

    Energy Technology Data Exchange (ETDEWEB)

    Kim, In Guk; Kim, Kyung Mo; Jeong, Yeong Shin; Bang, In Cheol [KAERI, Daejeon (Korea, Republic of)

    2016-05-15

    CAREM 25 (27 MWe safety systems using hydraulic control rod drives (CRD) studied critical issues that were rod drops with interrupted flow [3]. Hydraulic control rod drive suggested fast shutdown condition using a large gap between piston and cylinder in order to fast drop of neutron absorbing rods. A Passive IN-core Cooling system (PINCs) was suggested for safety enhancement of pressurized water reactors (PWR), small modular reactor (SMR), sodium fast reactor (SFR) in UNIST. PINCs consist of hydraulic control rod drive mechanism (Hydraulic CRDM) and hybrid control rod assembly with heat pipe combined with control rod. The schematic diagram of the hydraulic CRDM for PINCs is shown in Fig. 1. The experimental results show the steady state and transient behavior of the upper cylinder at a low pressure and low temperature. The influence of the working fluid temperature and cylinder mass are investigated. Finally, the heat removal between evaporator section and condenser section is compared with or without the hybrid control rod. Heat removal test of the hybrid heat pipe with hydraulic CRDM system showed the heat transfer coefficient of the bundle hybrid control rod and its effect on evaporator pool. The preliminary test both hydraulic CRDM and heat removal system was conducted, which showed the possibility of the in-core hydraulic drive system for application of PINCs.

  15. Screwing or unscrewing device for studs or bolls of big dimension

    International Nuclear Information System (INIS)

    Sevelinge, G.; Bourdonne, J.C.

    1988-01-01

    The device for screwing or unscrewing large studs or bolts has a system determining the optimun screwing position and orientation of the bolt, a variable speed bidirectional drive a pin holding the bolt axially and system compensating the weight of the bolt with an hydraulic jack with a pressure detector to which the drive is slaved [fr

  16. METHODS FOR IMPROVING THE ENERGY EFFICIENCY OF WELL ROD PUMP UNITS

    Directory of Open Access Journals (Sweden)

    BRUNMAN1 Vladimir E.

    2016-11-01

    Full Text Available The concept of oil production energy efficiency improvement of good rod pumps by utilization of kinetic energy of the downward moving rod in capacitor bank is proposed. A mathematical model of the system is developed. Criteria of reduction of the peak values of current, consuming power and elimination of oscillations are obtained. It is shown that the developed system is capable of reducing the consumption of current twice and the peak power by three times. Thus it is possible to reduce operational and capital costs by reducing the cross-section of the feeder cables and decreasing the power of input transformers and diesel generator set if autonomous feeding of pumping units is used

  17. Biomechanical evaluation of a second generation headless compression screw for ankle arthrodesis in a cadaver model.

    Science.gov (United States)

    Somberg, Andrew Max; Whiteside, William K; Nilssen, Erik; Murawski, Daniel; Liu, Wei

    2016-03-01

    Many types of screws, plates, and strut grafts have been utilized for ankle arthrodesis. Biomechanical testing has shown that these constructs can have variable stiffness. More recently, headless compression screws have emerged as an evolving method of achieving compression in various applications but there is limited literature regarding ankle arthrodesis. The aim of this study was to determine the biomechanical stability provided by a second generation fully threaded headless compression screw compared to a standard headed, partially threaded cancellous screw in a cadaveric ankle arthrodesis model. Twenty fresh frozen human cadaver specimens were subjected to simulated ankle arthrodesis with either three standard cancellous-bone screws (InFix 7.3mm) or with three headless compression screws (Acumed Acutrak 2 7.5mm). The specimens were subjected to cyclic loading and unloading at a rate of 1Hz, compression of 525 Newtons (N) and distraction of 20N for a total of 500 cycles using an electromechanical load frame (Instron). The amount of maximum distraction was recorded as well as the amount of motion that occurred through 1, 10, 50, 100, and 500 cycles. No significant difference (p=0.412) was seen in the amount of distraction that occurred across the fusion site for either screw. The average maximum distraction after 500 cycles was 201.9μm for the Acutrak 2 screw and 235.4μm for the InFix screw. No difference was seen throughout each cycle over time for the Acutrak 2 screw (p-value=0.988) or the InFix screw (p-value=0.991). Both the traditional InFix type screw and the second generation Acumed Acutrak headless compression screws provide adequate fixation during ankle arthrodesis under submaximal loads. There is no demonstrable difference between traditional cannulated partially threaded screws and headless compression screws studied in this model. Copyright © 2015 European Foot and Ankle Society. Published by Elsevier Ltd. All rights reserved.

  18. An Online Fault Pre-warning System of the Rolling Mill Screw-down Device Based on Virtual Instrument

    Directory of Open Access Journals (Sweden)

    Qing Bai

    2014-04-01

    Full Text Available A traditional off-line screw-down monitoring system performs not well on real-time signal analysis or process, which cannot provide simultaneous fault pre-warning either. A diagnostic monitoring system as well as a remotely accessible graphic user interface is presented in this paper. The main objective of this work is to develop an online and available technique for monitoring the kinetic, hydrodynamic and electrical parameters of the rolling mill screw-down device, and analyze these figures to support online fault pre-warning. A series of transducers are installed in suitable locations to measure parameters decried above including the vibration acceleration of a rolling mill stand, the rolling force of a screw-down device, the stroke of a hydraulic cylinder, the system source pressure, the in-cylinder stress and the output value of an electro-hydraulic servo valve. An industrial personal computer picks up the information transformed by an extra high-speed data acquisition board embedded inside, processes the signals via a software designed by means of Laborary Virtual Instrument Engineering Workbench (LabVIEW and indicates fault conditions through the graphic user interface. Besides, the data of the overall system can be published over the Internet using LabVIEW Web Server capabilities. The results of experiments suggest that the system works well on real-time data acquisition and online fault pre- warning. The statistics saved contributes to the research of vibration performance and malfunction analysis of a rolling mill.

  19. Integrated control rod monitoring device

    International Nuclear Information System (INIS)

    Saito, Katsuhiro

    1997-01-01

    The present invention provides a device in which an entire control rod driving time measuring device and a control rod position support device in a reactor building and a central control chamber are integrated systematically to save hardwares such as a signal input/output device and signal cables between boards. Namely, (1) functions of the entire control rod driving time measuring device for monitoring control rods which control the reactor power and a control rod position indication device are integrated into one identical system. Then, the entire devices can be made compact by the integration of the functions. (2) The functions of the entire control rod driving time measuring device and the control rod position indication device are integrated in a central operation board and a board in the site. Then, the place for the installation of them can be used in common in any of the cases. (3) The functions of the entire control rod driving time measuring device and the control rod position indication device are integrated to one identical system to save hardware to be used. Then, signal input/output devices and drift branching panel boards in the site and the central operation board can be saved, and cables for connecting both of the boards is no more necessary. (I.S.)

  20. The applicability of PEEK-based abutment screws.

    Science.gov (United States)

    Schwitalla, Andreas Dominik; Abou-Emara, Mohamed; Zimmermann, Tycho; Spintig, Tobias; Beuer, Florian; Lackmann, Justus; Müller, Wolf-Dieter

    2016-10-01

    The high-performance polymer PEEK (poly-ether-ether-ketone) is more and more being used in the field of dentistry, mainly for removable and fixed prostheses. In cases of screw-retained implant-supported reconstructions of PEEK, an abutment screw made of PEEK might be advantageous over a conventional metal screw due to its similar elasticity. Also in case of abutment screw fracture, a screw of PEEK could be removed more easily. M1.6-abutment screws of four different PEEK compounds were subjected to tensile tests to set their maximum tensile strengths in relation to an equivalent stress of 186MPa, which is aused by a tightening torque of 15Ncm. Two screw types were manufactured via injection molding and contained 15% short carbon fibers (sCF-15) and 40% (sCF-40), respectively. Two screw types were manufactured via milling and contained 20% TiO2 powder (TiO2-20) and >50% parallel orientated, continuous carbon fibers (cCF-50). A conventional abutments screw of Ti6Al4V (Ti; CAMLOG(®) abutment screw, CAMLOG, Wimsheim, Germany) served as control. The maximum tensile strength was 76.08±5.50MPa for TiO2-20, 152.67±15.83MPa for sCF-15, 157.29±20.11MPa for sCF-40 and 191.69±36.33MPa for cCF-50. The maximum tensile strength of the Ti-screws amounted 1196.29±21.4MPa. The results of the TiO2-20 and the Ti screws were significantly different from the results of the other samples, respectively. For the manufacturing of PEEK abutment screws, PEEK reinforced by >50% continuous carbon fibers would be the material of choice. Copyright © 2016 Elsevier Ltd. All rights reserved.

  1. Maximum/minimum asymmetric rod detection

    International Nuclear Information System (INIS)

    Huston, J.T.

    1990-01-01

    This patent describes a system for determining the relative position of each control rod within a control rod group in a nuclear reactor. The control rod group having at least three control rods therein. It comprises: means for producing a signal representative of a position of each control rod within the control rod group in the nuclear reactor; means for establishing a signal representative of the highest position of a control rod in the control rod group in the nuclear reactor; means for establishing a signal representative of the lowest position of a control rod in the control rod group in the nuclear reactor; means for determining a difference between the signal representative of the position of the highest control rod and the signal representative of the position of the lowest control rod; means for establishing a predetermined limit for the difference between the signal representative of the position of the highest control rod and the signal representative of the position of the lowest control rod; and means for comparing the difference between the signals with the predetermined limit. The comparing means producing an output signal when the difference between the signals exceeds the predetermined limit

  2. Pull out Strength of Dual Outer Diameter Pedicle Screws Compared to Uncemented and Cemented Standard Pedicle Screws: A Biomechanical in vitro Study.

    Science.gov (United States)

    Lorenz, Andrea; Leichtle, Carmen I; Frantz, Sandra; Bumann, Marte; Tsiflikas, Ilias; Shiozawa, Thomas; Leichtle, Ulf G

    2017-05-01

    To analyze the potential of the dual outer diameter screw and systematically evaluate the pull-out force of the dual outer diameter screw compared to the uncemented and cemented standard pedicle screws with special regard to the pedicle diameter and the vertebra level. Sixty vertebrae of five human spines (T 6 -L 5 ) were sorted into three study groups for pairwise comparison of the uncemented dual outer diameter screw, the uncemented standard screw, and the cemented standard screw, and randomized with respect to bone mineral density (BMD) and vertebra level. The vertebrae were instrumented, insertion torque was determined, and pull-out testing was performed using a material testing machine. Failure load was evaluated in pairwise comparison within each study group. The screw-to-pedicle diameter ratio was determined and the uncemented dual outer diameter and standard screws were compared for different ratios as well as vertebra levels. Significantly increased pull-out forces were measured for the cemented standard screw compared to the uncemented standard screw (+689 N, P dual outer diameter screw (+403 N, P dual outer diameter screw to the uncemented standard screw in the total study group, a distinct but not significant increase was measured (+149 N, P = 0.114). Further analysis of these two screws, however, revealed a significant increase of pull-out force for the dual outer diameter screw in the lumbar region (+247 N, P = 0.040), as well as for a screw-to-pedicle diameter ratio between 0.6 and 1 (+ 488 N, P = 0.028). For clinical application, cement augmentation remains the gold standard for increasing screw stability. According to our results, the use of a dual outer diameter screw is an interesting option to increase screw stability in the lumbar region without cement augmentation. For the thoracic region, however, the screw-to-pedicle diameter should be checked and attention should be paid to screw cut out, if the dual outer diameter screw is considered.

  3. Screw expander for light duty diesel engines

    Science.gov (United States)

    1983-01-01

    Preliminary selection and sizing of a positive displacement screw compressor-expander subsystem for a light-duty adiabatic diesel engine; development of a mathematical model to describe overall efficiencies for the screw compressor and expander; simulation of operation to establish overall efficiency for a range of design parameters and at given engine operating points; simulation to establish potential net power output at light-duty diesel operating points; analytical determination of mass moments of inertia for the rotors and inertia of the compressor-expander subsystem; and preparation of engineering layout drawings of the compressor and expander are discussed. As a result of this work, it was concluded that the screw compressor and expander designed for light-duty diesel engine applications are viable alternatives to turbo-compound systems, with acceptable efficiencies for both units, and only a moderate effect on the transient response.

  4. Design and test of a novel magnetic lead screw for active suspension system in a vehicle

    DEFF Research Database (Denmark)

    Berg, Nick Ilsø; Holm, Rasmus Koldborg; Rasmussen, Peter Omand

    2014-01-01

    . Furthermore the Magnetic Lead Screw is introduced and its benefits when used with an active suspension system are discussed. Based on a model of a quarter car, the design specifications for the MLS active suspension system are found, which leads to a design study. The design study investigates the relation...

  5. Current trends in pedicle screw stimulation techniques: lumbosacral, thoracic, and cervical levels.

    Science.gov (United States)

    Isley, Michael R; Zhang, Xiao-Feng; Balzer, Jeffrey R; Leppanen, Ronald E

    2012-06-01

    justification" of intraoperative neuromonitoring"... is the perception that the safety and efficacy of pedicle screw fixation are enhanced..." (Resnick et al. 2005b). However in summarizing a massive (over 1000 papers taken from the National Library of Medicine), contemporary, literature review spanning nearly a decade (1996 to 2003), this invited panel (Resnick et al. 2005b) recognized that the evidence-based documents contributing to the parts related to pedicle screw fixation and neuromonitoring were "... full of potential sources of error ..." and lacked appropriate, randomized, prospective studies for formulating rigid standards and guidelines. Nevertheless, current trends support the routine use and clinical utility of these neuromonitoring techniques. In particular free-run and triggered EMG have been well recognized in numerous publications for improving both the accuracy and safety of pedicle screw implantation. Currently, treatment with pedicle screw instrumentation routinely involves all levels of the spine - lumbosacral, thoracic, and cervical. Significant historical events, various neuromonitoring modalities, intraoperative alarm criteria, clinical efficacy, current trends, and caveats related to pedicle screw stimulation along the entire vertebral column will be reviewed.

  6. Measurement of Tip Apex Distance and Migration of Lag Screws and Novel Blade Screw Used for the Fixation of Intertrochanteric Fractures.

    Directory of Open Access Journals (Sweden)

    Jesse Chieh-Szu Yang

    Full Text Available Fixation with a dynamic hip screw (DHS is one of the most common methods for stabilizing intertrochanteric fractures, except for unstable and reverse oblique fracture types. However, failure is often observed in osteoporotic patients whereby the lag screw effectively 'cuts out' through the weak bone. Novel anti-migration blades have been developed to be used in combination with a lag screw ('Blade Screw' to improve the fixation strength in osteoporotic intertrochanteric fractures. An in-vitro biomechanical study and a retrospective clinical study were performed to evaluate lag screw migration when using the novel Blade Screw and a traditional threaded DHS. The biomechanical study showed both the Blade Screw and DHS displayed excessive migration (≥10 mm before reaching 20,000 loading cycles in mild osteoporotic bone, but overall migration of the Blade Screw was significantly less (p ≤ 0.03. Among the patients implanted with a Blade Screw in the clinical study, there was no significant variation in screw migration at 3-months follow-up (P = 0.12. However, the patient's implanted with a DHS did display significantly greater migration (P<0.001 than those implanted with the Blade Screw. In conclusion, the Blade Screw stabilizes the bone fragments during dynamic loading so as to provide significantly greater resistance to screw migration in patients with mild osteoporosis.

  7. Comparison of effectiveness between cork-screw and peg-screw electrodes for transcranial motor evoked potential monitoring using the finite element method.

    Science.gov (United States)

    Tomio, Ryosuke; Akiyama, Takenori; Ohira, Takayuki; Yoshida, Kazunari

    2016-01-01

    Intraoperative monitoring of motor evoked potentials by transcranial electric stimulation is popular in neurosurgery for monitoring motor function preservation. Some authors have reported that the peg-screw electrodes screwed into the skull can more effectively conduct current to the brain compared to subdermal cork-screw electrodes screwed into the skin. The aim of this study was to investigate the influence of electrode design on transcranial motor evoked potential monitoring. We estimated differences in effectiveness between the cork-screw electrode, peg-screw electrode, and cortical electrode to produce electric fields in the brain. We used the finite element method to visualize electric fields in the brain generated by transcranial electric stimulation using realistic three-dimensional head models developed from T1-weighted images. Surfaces from five layers of the head were separated as accurately as possible. We created the "cork-screws model," "1 peg-screw model," "peg-screws model," and "cortical electrode model". Electric fields in the brain radially diffused from the brain surface at a maximum just below the electrodes in coronal sections. The coronal sections and surface views of the brain showed higher electric field distributions under the peg-screw compared to the cork-screw. An extremely high electric field was observed under cortical electrodes. Our main finding was that the intensity of electric fields in the brain are higher in the peg-screw model than the cork-screw model.

  8. The Study of Vibration Processes in Oil Flooded Screw Compressors

    Directory of Open Access Journals (Sweden)

    I. V. Filippov

    2014-01-01

    system with vibration acceleration feedback. Such system implementation will allow us to exclude extremely dangerous regimes of polytrophic boosting during discharge phase when there is mismatch between the internal compression pressure of the oil flooded screw compressor and that of in discharge line.

  9. Mechanical reliability of falling systems. Case of control rods of nuclear reactors

    International Nuclear Information System (INIS)

    Rezkallah, B.

    1991-05-01

    After having briefly recalled the main principles adopted for nuclear reactor safety (barrier based method, emergency stop system, emergency cooling system) and how control rod operation anomalies are described, this research thesis first gives an overview of knowledge in the field of reliability (principles, qualitative and quantitative methods, failure trees, performance function, shock modelling and mode analysis). Then, the author presents the modelling of the drop and rotation of a control rod. The computation technique is the modal synthesis. The author highlights the influence of physical (friction, initial conditions) and numerical (modal truncation) parameters. He reports a probabilistic analysis of the problem and proposes a stochastic model for the different shock forces (notably friction). He compares the results with those obtained with the DEMT software. The last part reports the investigation of a rare case: the jamming or untimely stop of the control rod device

  10. An operational 150 kV microfocus rod anode X-ray system for nondestructive testing

    International Nuclear Information System (INIS)

    Fontijn, E.A.

    1978-01-01

    This paper describes an operational state of the art 150 kV microfocus rod anode X-ray system having ultra-high radiographic resolution capabilities. A cocal spot size of 0.050 mm is provided. Heretofore unattainable long rod anode lengths coupled with very small diameters are now possible using mini-magnetic lens technology. Over-all rod anode diameters as small as 9 mm with useful lengths of 1 m or more are possible, permitting panoramic inspections where previously only lower resolution radioisotope radiographic techniques were possible. Radiographic sensitivity of better than 1% has been reported with film-focal-distances on the order of 8 mm through 3 mm of steel. The system has been successfully applied to steam generator and heat exchanger tube-to-tubesheet weldments in both Europe and the USA. Other application areas include marine and aircraft jet engine inspection and numerous other applications where high reliability requirements indicate the use of a ultra-sensitive radiographic technique as is routinely demonstrated with the 150 kV Microfocus Rod Anode X-ray System. (orig.) [de

  11. Temperature studies of the TileCal ROD G-Links for the validation of the air-cooling system

    CERN Document Server

    Valero, A; Abdallah, J; Castillo, V; Cuenca, C; Ferrer, A; Fullana, E; González, V; Higón, E; Munar, A; Poveda, J; Salvachúa, B; Sanchis, E; Solans, C; Torres, J; Valls, J A

    2007-01-01

    In this paper we show the results of the temperature studies performed on the TileCal ROD G-Links in order to validate the air-cooling system. In the first part of the note we present results on the characterization tests of the temperature monitor system for the G-Link chips of the TileCal ROD motherboard, performed at IFIC-Valencia. We report on the performance of the temperature behavior system and some cooling studies of a single ROD motherboard. We conclude that the present system can be successfully used to online monitor the temperature of the ROD G-Links. In the second part we show the results of the studies performed with multiple RODs in a standard 9U VME crate in the laboratory at IFIC, and in their final location in the ATLAS cavern. We conclude that the air-cooling provided by the standard VME crate fans is enough to keep the temperature of the G-Links well within specifications.

  12. Analysis on Accuracy of Bias, Linearity and Stability of Measurement System in Ball screw Processes by Simulation

    Directory of Open Access Journals (Sweden)

    Fan-Yun Pai

    2015-11-01

    Full Text Available To consistently produce high quality products, a quality management system, such as the ISO9001, 2000 or TS 16949 must be practically implemented. One core instrument of the TS16949 MSA (Measurement System Analysis is to rank the capability of a measurement system and ensure the quality characteristics of the product would likely be transformed through the whole manufacturing process. It is important to reduce the risk of Type I errors (acceptable goods are misjudged as defective parts and Type II errors (defective parts are misjudged as good parts. An ideal measuring system would have the statistical characteristic of zero error, but such a system could hardly exist. Hence, to maintain better control of the variance that might occur in the manufacturing process, MSA is necessary for better quality control. Ball screws, which are a key component in precision machines, have significant attributes with respect to positioning and transmitting. Failures of lead accuracy and axial-gap of a ball screw can cause negative and expensive effects in machine positioning accuracy. Consequently, a functional measurement system can incur great savings by detecting Type I and Type II errors. If the measurement system fails with respect to specification of the product, it will likely misjudge Type I and Type II errors. Inspectors normally follow the MSA regulations for accuracy measurement, but the choice of measuring system does not merely depend on some simple indices. In this paper, we examine the stability of a measuring system by using a Monte Carlo simulation to establish bias, linearity variance of the normal distribution, and the probability density function. Further, we forecast the possible area distribution in the real case. After the simulation, the measurement capability will be improved, which helps the user classify the measurement system and establish measurement regulations for better performance and monitoring of the precision of the ball screw.

  13. Radiological outcome of transpedicular screws fixation in the management of thoracolumbar spine injury

    International Nuclear Information System (INIS)

    Haq, M.I.U.

    2015-01-01

    Traumatic fracture of the spine is a serious neurosurgical condition that has serious impact on the patient's quality of life. Thoracolumbar junction is the most common site of spinal injuries. The aims of management of thoracolumbar spinal fractures are to restore vertebral column stability, and to obtain spinal canal decompression. This ultimately leads to early mobilization of the patients. This study was conducted to compare preoperative and post-operative vertebral height, kyphotic angle and sagittal index in patients treated with pedicle screws and rods in thoracolumbar spine fractures. Methods: This cross-sectional study was conducted in the department of Neurosurgery, Hayatabad Medical Complex, Peshawar from 1st February 2010 to 31st July 2011. A total 161 patients with unstable thoracolumber spine fracture were included in this study. In these patients fixation was done through transpedicle screws with rods. Anteroposterior and lateral views X-rays of thoraco-lumbar spine were done pre and post operatively. Results: Out of 161 patients, 109 (67.7%) were males and 52 (32.3%) females. The age of patients ranged from 20 to 70 years (mean 42.2 years) with 71 (44.1%) in the age range of 31-40 years. Preoperative average vertebral height was 9.4194 mm while postoperative average was 19.642 mm. The mean kyphosis was 23.06 degree preoperatively. Immediately after surgery the average correction of kyphosis was 9.45 degree. The pre-operative average sagittal index was 19.38 degree, which was reduced to an average 5.41 degree post operatively. Conclusions: Transpedicular fixation for unstable thoraco-lumbar spinal fractures achieves a stable fracture segment with improvement of vertebral height, kyphotic angle and sagittal index. Hence, preventing the secondary spinal deformities. (author)

  14. Magnetic switch for reactor control rod

    International Nuclear Information System (INIS)

    Germer, J.H.

    1986-01-01

    This patent describes a control rod system for a nuclear reactor utilizing an electromagnetic grapple mechanism for holding and releasing a control rod, the improvement comprising a magnetic reed switch assembly having a Curie-point magnetic shunt and responsive to reactor coolant temperature for short circuiting the electromagnetic grapple mechanism causing release of the control rod when the coolant temperature reaches the Curie-point of the magnetic shunt. The magnetic reed switch assembly includes a: a permanent magnet, a pair of magnetic pole pieces located at and in contact with opposite ends of the permanent magnet, the Curie-point magnetic shunt being positioned adjacent the permanent magnet and in contact with the pair of magnetic pole pieces, and a reed switch positioned intermediate the pole pieces and provided with a pair of ferromagnetic reeds, a nonmagnetic enclosure around the reeds, a first of the reeds being secured at one end to a first of the pair of pole pieces, a second of the reeds having one end extending into and secured to a hollow member positioned in and extending through a second of the pair of pole pieces, the one end of the second of the reeds secured to a condector adapted to be connected to the electromagnetic grapple mechanism

  15. Clinch River Breeder Reactor secondary control rod system

    International Nuclear Information System (INIS)

    McKeehan, E.R.; Sim, R.G.

    1977-01-01

    The shutdown system for the Clinch River Breeder Reactor (CRBR) includes two independent systems--a primary and a secondary system. The Secondary Control Rod System (SCRS) is a new design which is being developed by General Electric to be independent from the primary system in order to improve overall shutdown reliability by eliminating potential common-mode failures. The paper describes the status of the SCRS design and fabrication and testing activities. Design verification testing on the component level is largely complete. These component tests are covered with emphasis on design impact results. A prototype unit has been manufactured and system level tests in sodium have been initiated

  16. Comparison of open reduction versus minimally invasive surgical approaches on screw position in canine sacroiliac lag-screw fixation.

    Science.gov (United States)

    Déjardin, Loïc M; Marturello, Danielle M; Guiot, Laurent P; Guillou, Reunan P; DeCamp, Charles E

    2016-07-19

    To compare accuracy and consistency of sacral screw placement in canine pelves treated for sacroiliac luxation with open reduction and internal fixation (ORIF) or minimally invasive osteosynthesis (MIO) techniques. Unilateral sacroiliac luxations created experimentally in canine cadavers were stabilized with an iliosacral lag screw applied via ORIF or MIO techniques (n = 10/group). Dorsoventral and craniocaudal screw angles were measured using computed tomography multiplanar reconstructions in transverse and dorsal planes, respectively. Ratios between pilot hole length and sacral width (PL/SW-R) were obtained. Data between groups were compared statistically (p sacroiliac luxations provides more accurate and consistent sacral screw placement than ORIF. With proper techniques, iatrogenic neurological damage can be avoided with both techniques. The PL /SW-R, which relates to safe screw fixation, also demonstrates that screw penetration of at least 60% of the sacral width is achievable regardless of surgical approach. These findings, along with the limited dissection needed for accurate sacral screw placement, suggest that MIO of sacroiliac luxations is a valid alternative to ORIF.

  17. Percutaneous anterior C1/2 transarticular screw fixation: salvage of failed percutaneous odontoid screw fixation for odontoid fracture

    OpenAIRE

    Wu, Ai-Min; Jin, Hai-Ming; Lin, Zhong-Ke; Chi, Yong-Long; Wang, Xiang-Yang

    2017-01-01

    Background The objective of this study is to investigate the outcomes and safety of using percutaneous anterior C1/2 transarticular screw fixation as a salvage technique for odontoid fracture if percutaneous odontoid screw fixation fails. Methods Fifteen in 108 odontoid fracture patients (planned to be treated by percutaneous anterior odontoid screw fixation) were failed to introduce satisfactory odontoid screw trajectory. To salvage this problem, we chose the percutaneous anterior C1/2 trans...

  18. Research on the performance of water-injection twin screw compressor

    International Nuclear Information System (INIS)

    Li Jianfeng; Wu Huagen; Wang Bingming; Xing Ziwen; Shu Pengcheng

    2009-01-01

    Due to the development of the automotive fuel cell systems, the study on water-injection twin screw compressor has been aroused again. Twin screw compressors with water injection can be used to supply the clean compressed air for the Proton Exchange Membrane (PEM) fuel cell systems. In this research, a thermodynamic model of the working process of water-injection twin screw compressor was established based on the equations of conservation of mass and energy. The effects of internal leakage and air-water heat transfer were taken into account simultaneously in the present mathematical model. The experiments of the performance of a prototype compressor operating under various conditions were conducted to verify the model. The results show that the predictions of the model are in reasonable agreement with the experimental data.

  19. SSYST. A code system to analyze LWR fuel rod behavior under accident conditions

    International Nuclear Information System (INIS)

    Gulden, W.; Meyder, R.; Borgwaldt, H.

    1982-01-01

    SSYST (Safety SYSTem) is a modular system to analyze the behavior of light water reactor fuel rods and fuel rod simulators under accident conditions. It has been developed in close cooperation between Kernforschungszentrum Karlsruhe (KfK) and the Institut fuer Kerntechnik und Energiewandlung (IKE), University Stuttgart, under contract of Projekt Nukleare Sicherheit (PNS) at KfK. Although originally aimed at single rod analysis, features are available to calculate effects such as blockage ratios of bundles and wholes cores. A number of inpile and out-of-pile experiments were used to assess the system. Main differences versus codes like FRAP-T with similar applications are (1) an open-ended modular code organisation, (2) availability of modules of different sophistication levels for the same physical processes, and (3) a preference for simple models, wherever possible. The first feature makes SSYST a very flexible tool, easily adapted to changing requirements; the second enables the user to select computational models adequate to the significance of the physical process. This leads together with the third feature to short execution times. The analysis of transient rod behavior under LOCA boundary conditions e.g. takes 2 mins cpu-time (IBM-3033), so that extensive parametric studies become possible

  20. Inspection and replacement of baffle assembly screws inside American reactor vessels

    International Nuclear Information System (INIS)

    Neal, K.; Chaumont, J.C.

    1999-01-01

    The baffle assembly inside the vessel of a 900 MWe reactor designed by Framatome, is made up of 44 plates fixed on 8 horizontal supports by a system of about 1000 screws. These plates undergo high neutron flux and the problem of screw cracking appeared at the end of the eighties in the first-generation reactors. The first operation on a large scale concerning the screws of a Westinghouse type reactor, was performed on the Tihange-1 power plant where Framatome controlled 960 screws and replaced 91. In 1997 as a consequence of the Belgian and French feedback experience, American plant operators launched a vast program of preventive actions: material analysis, inspection of baffle plate screws and replacement of defective screws. This program was held in cooperation with EPRI (electric power research institute) and under the control of NRC (nuclear regulatory commission). Framatome Technologies Inc (FTI) was in charge of the in-situ inspection and replacement of the screws. FTI designed special tools and equipment adapted to the 2-loop American reactors but the basis ideas were those applied on the Tihange reactor. The successful experience of FTI has allowed the firm to be commissioned for 6 2-loops American reactors. (A.C.)

  1. Standard Waste Box Lid Screw Removal Option Testing

    International Nuclear Information System (INIS)

    Anast, Kurt Roy

    2016-01-01

    This report provides results from test work conducted to resolve the removal of screws securing the standard waste box (SWB) lids that hold the remediated nitrate salt (RNS) drums. The test work evaluated equipment and process alternatives for removing the 42 screws that hold the SWB lid in place. The screws were secured with a red Loctite thread locker that makes removal very difficult because the rivets that the screw threads into would slip before the screw could be freed from the rivet, making it impossible to remove the screw and therefore the SWB lid.

  2. Standard Waste Box Lid Screw Removal Option Testing

    Energy Technology Data Exchange (ETDEWEB)

    Anast, Kurt Roy [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2016-03-11

    This report provides results from test work conducted to resolve the removal of screws securing the standard waste box (SWB) lids that hold the remediated nitrate salt (RNS) drums. The test work evaluated equipment and process alternatives for removing the 42 screws that hold the SWB lid in place. The screws were secured with a red Loctite thread locker that makes removal very difficult because the rivets that the screw threads into would slip before the screw could be freed from the rivet, making it impossible to remove the screw and therefore the SWB lid.

  3. Sucker rod string design of the pumping systems

    OpenAIRE

    Hua. L, C

    2015-01-01

    The existing design of sucker rod string mainly focuses on the simplifying assumptions that rod string was exposed to simple tension loading. And its goal was to have equal modified stress at the top of each taper. The improved rod design was to have the same degree of safety at each section, and it used a dynamic force distribution that was proportional along the whole string. Moreover, the available procedures did not provide the desired accuracy of its pertinent analysis, and the operators...

  4. Hysteresis, reentrance, and glassy dynamics in systems of self-propelled rods.

    Science.gov (United States)

    Kuan, Hui-Shun; Blackwell, Robert; Hough, Loren E; Glaser, Matthew A; Betterton, M D

    2015-01-01

    Nonequilibrium active matter made up of self-driven particles with short-range repulsive interactions is a useful minimal system to study active matter as the system exhibits collective motion and nonequilibrium order-disorder transitions. We studied high-aspect-ratio self-propelled rods over a wide range of packing fractions and driving to determine the nonequilibrium state diagram and dynamic properties. Flocking and nematic-laning states occupy much of the parameter space. In the flocking state, the average internal pressure is high and structural and mechanical relaxation times are long, suggesting that rods in flocks are in a translating glassy state despite overall flock motion. In contrast, the nematic-laning state shows fluidlike behavior. The flocking state occupies regions of the state diagram at both low and high packing fraction separated by nematic-laning at low driving and a history-dependent region at higher driving; the nematic-laning state transitions to the flocking state for both compression and expansion. We propose that the laning-flocking transitions are a type of glass transition that, in contrast to other glass-forming systems, can show fluidization as density increases. The fluid internal dynamics and ballistic transport of the nematic-laning state may promote collective dynamics of rod-shaped micro-organisms.

  5. Misplaced Cervical Screws Requiring Reoperation.

    Science.gov (United States)

    Peterson, Jeremy C; Arnold, Paul M; Smith, Zachary A; Hsu, Wellington K; Fehlings, Michael G; Hart, Robert A; Hilibrand, Alan S; Nassr, Ahmad; Rahman, Ra'Kerry K; Tannoury, Chadi A; Tannoury, Tony; Mroz, Thomas E; Currier, Bradford L; De Giacomo, Anthony F; Fogelson, Jeremy L; Jobse, Bruce C; Massicotte, Eric M; Riew, K Daniel

    2017-04-01

    A multicenter, retrospective case series. In the past several years, screw fixation of the cervical spine has become commonplace. For the most part, this is a safe, low-risk procedure. While rare, screw backout or misplaced screws can lead to morbidity and increased costs. We report our experiences with this uncommon complication. A multicenter, retrospective case series was undertaken at 23 institutions in the United States. Patients were included who underwent cervical spine surgery from January 1, 2005, to December 31, 2011, and had misplacement of screws requiring reoperation. Institutional review board approval was obtained at all participating institutions, and detailed records were sent to a central data center. A total of 12 903 patients met the inclusion criteria and were analyzed. There were 11 instances of screw backout requiring reoperation, for an incidence of 0.085%. There were 7 posterior procedures. Importantly, there were no changes in the health-related quality-of-life metrics due to this complication. There were no new neurologic deficits; a patient most often presented with pain, and misplacement was diagnosed on plain X-ray or computed tomography scan. The most common location for screw backout was C6 (36%). This study represents the largest series to tabulate the incidence of misplacement of screws following cervical spine surgery, which led to revision procedures. The data suggest this is a rare event, despite the widespread use of cervical fixation. Patients suffering this complication can require revision, but do not usually suffer neurologic sequelae. These patients have increased cost of care. Meticulous technique and thorough knowledge of the relevant anatomy are the best means of preventing this complication.

  6. Technical measurement of small fission gas inventory in fuel rod with laser puncturing system

    International Nuclear Information System (INIS)

    Kim, Hee Moon; Kim, Sung Ryul; Lee, Byoung Oon; Yang, Yong Sik; Baek, Sang Ryul; Song, Ung Sup

    2012-01-01

    The fission gas release cause degradation of fuel rod. It influences fuel temperature and internal pressure due to low thermal conductivity. Therefore, fission gas released to internal void of fuel rod must be measured with burnup. To measure amount of fission gas, fuel rod must be punctured by a steel needle in a closed chamber. Ideal gas law(PV=nRT) is applied to obtain atomic concentration(mole). Steel needle type is good for large amount of fission gas such as commercial spent fuel rod. But, some cases with small fuel rig in research reactor for R/D program are not available to use needle type because of large chamber volume. The laser puncturing technique was developed to solve measurement of small amount of fission gas. This system was very rare equipment in other countries. Fine pressure gage and strong vacuum system were installed, and the chamber volume was reduced at least. Fiber laser was used for easy operation

  7. An unusual case of orbito-frontal rod fence stab injury with a good outcome.

    Science.gov (United States)

    Miscusi, Massimo; Arangio, Paolo; De Martino, Luca; De-Giorgio, Fabio; Cascone, Piero; Raco, Antonino

    2013-08-13

    High-energy non-missile penetrating injuries (stab injuries) account for a small percentage of penetrating head injuries and they present a series of special features. A 35-year-old man suffered orbito-frontal? and trans-cranial injuries after falling five meters from a terrace onto a rod iron fence. The removal of the metal rod was performed outside the operating room. The orbital roof was exposed and repaired through a bifrontal craniotomy and the frontal sinuses were cranialised. The orbital floor and zygoma were plated with micro-screws. The patient recovered without significant complications, apart from a slight paresis of the right superior rectus; the ocular globe remained intact.The positive outcome obtained in this very challenging case is attributable to the competency of the Neurotrauma Unit and to the use of a synergistic approach which involved the contribution of neurosurgeons, maxillo-facial surgeons, radiologists and anaesthesiologists.

  8. Different phases of a system of hard rods on three dimensional cubic lattice

    Science.gov (United States)

    Vigneshwar, N.; Dhar, Deepak; Rajesh, R.

    2017-11-01

    We study the different phases of a system of monodispersed hard rods of length k on a cubic lattice, using an efficient cluster algorithm able to simulate densities close to the fully-packed limit. For k≤slant 4 , the system is disordered at all densities. For k=5, 6 , we find a single density-driven transition, from a disordered phase to high density layered-disordered phase, in which the density of rods of one orientation is strongly suppressed, breaking the system into weakly coupled layers. Within a layer, the system is disordered. For k ≥slant 7 , three density-driven transitions are observed numerically: isotropic to nematic to layered-nematic to layered-disordered. In the layered-nematic phase, the system breaks up into layers, with nematic order in each layer, but very weak correlation between the ordering directions of different layers. We argue that the layered-nematic phase is a finite-size effect, and in the thermodynamic limit, the nematic phase will have higher entropy per site. We expect the systems of rods in four and higher dimensions will have a qualitatively similar phase diagram.

  9. Prototypical Rod Consolidation Demonstration Project

    International Nuclear Information System (INIS)

    1993-05-01

    The objective of Phase III of the Prototypical Rod Consolidation Demonstration Project (PRCDP) was to procure, fabricate, assemble, and test the Prototypical Rod Consolidation System as described in the NUS Phase II Final Design Report. This effort required providing the materials, components, and fabricated parts which makes up all of the system equipment. In addition, it included the assembly, installation, and setup of this equipment at the Cold Test Facility. During the Phase III effort the system was tested on a component, subsystem, and system level. Volume IV provides the Operating and Maintenance Manual for the Prototypical Rod Consolidation System that was installed at the Cold Test Facility. This document, Book 1 of Volume IV, discusses: Process overview functional descriptions; Control system descriptions; Support system descriptions; Maintenance system descriptions; and Process equipment descriptions

  10. Dynamic modelling and PID loop control of an oil-injected screw compressor package

    Science.gov (United States)

    Poli, G. W.; Milligan, W. J.; McKenna, P.

    2017-08-01

    A significant amount of time is spent tuning the PID (Proportional, Integral and Derivative) control loops of a screw compressor package due to the unique characteristics of the system. Common mistakes incurred during the tuning of a PID control loop include improper PID algorithm selection and unsuitable tuning parameters of the system resulting in erratic and inefficient operation. This paper details the design and development of software that aims to dynamically model the operation of a single stage oil injected screw compressor package deployed in upstream oil and gas applications. The developed software will be used to assess and accurately tune PID control loops present on the screw compressor package employed in controlling the oil pressures, temperatures and gas pressures, in a bid to improve control of the operation of the screw compressor package. Other applications of the modelling software will include its use as an evaluation tool that can estimate compressor package performance during start up, shutdown and emergency shutdown processes. The paper first details the study into the fundamental operational characteristics of each of the components present on the API 619 screw compressor package and then discusses the creation of a dynamic screw compressor model within the MATLAB/Simulink software suite. The paper concludes by verifying and assessing the accuracy of the created compressor model using data collected from physical screw compressor packages.

  11. Control rod

    International Nuclear Information System (INIS)

    Kawakami, Kazuo; Shimoshige, Takanori; Nishimura, Akira

    1979-01-01

    Purpose: A control rod has been developed, which provided a plurality of through-holes in the vicinity of the sheath fitting position, in order to flatten burn-up, of fuel rods in positions confronting a control rod. Thereby to facilitate the manufacture of the control rods and prevent fuel rod failures. Constitution: A plurality of through-holes are formed in the vicinity of the sheath fitting position of a central support rod to which a sheath for the control rod is fitted. These through-holes are arranged in the axial direction of the central support rod. Accordingly, burn-up of fuel rods confronting the control rods can be reduced by through-holes and fuel rod failures can be prevented. (Yoshino, Y.)

  12. A rule-based expert system for control rod pattern of boiling water reactors by hovering around haling exposure shape

    International Nuclear Information System (INIS)

    Kao, P.-W.; Lin, L.-S.; Yang, J.-T.

    2004-01-01

    Feasible strategies for automatic BWR control rod pattern generation have been implemented in a rule-based expert system. These strategies are majorly based on a concept for which exposure distributions are hovering around the Haling exposure distribution through a cycle while radial and axial power distributions are dominantly controlled by some abstracted factors indicating the desired distributions. The system can either automatically generate expert-level control rod patterns or search for criteria-satisfied patterns originated from user's input. It has successfully been demonstrated by generating control rod patterns for the the 1775 MWth Chinshan plant in Unit I Cycle 13 alternate loading pattern and Unit 2 Cycle 8 but with longer cycle length. All rod patterns for two cycles result in all-rod-out at EOC and no violation against the four criteria. The demonstrations show that the system is considerably good in choosing initial trial rod patterns and adjusting rod patterns to satisfy the design criteria. (author)

  13. Tricortical cervical inter-body screw fixation.

    Directory of Open Access Journals (Sweden)

    Goel A

    1997-01-01

    Full Text Available A new tricortical method of screw implantation for anterior cervical interbody plate fixation is described. The screws are placed obliquely such that they engage the anterior cortex of the body and traverse through the cortices adjoining the disc space. By this method the screws not only hold the plate firmly with a tricortical purchase, but by virtue of their course stabilize the two adjoining vertebral bodies by themselves. Sixteen patients were treated by this method. In three of these cases only tricortical screws without the metal plate were used for fixation. The advantages of the technique are discussed.

  14. Accuracy of S2 Alar-Iliac Screw Placement Under Robotic Guidance.

    Science.gov (United States)

    Laratta, Joseph L; Shillingford, Jamal N; Lombardi, Joseph M; Alrabaa, Rami G; Benkli, Barlas; Fischer, Charla; Lenke, Lawrence G; Lehman, Ronald A

    Case series. To determine the safety and feasibility of S2 alar-iliac (S2AI) screw placement under robotic guidance. Similar to standard iliac fixation, S2AI screws aid in achieving fixation across the sacropelvic junction and decreasing S1 screw strain. Fortunately, the S2AI technique minimizes prominent instrumentation and the need for offset connectors to the fusion construct. Herein, we present an analysis of the largest series of robotic-guided S2AI screws in the literature without any significant author conflicts of interest with the robotics industry. Twenty-three consecutive patients who underwent spinopelvic fixation with 46 S2AI screws under robotic guidance were analyzed from 2015 to 2016. Screws were placed by two senior spine surgeons, along with various fellow or resident surgical assistants, using a proprietary robotic guidance system (Renaissance; Mazor Robotics Ltd., Caesara, Israel). Screw position and accuracy was assessed on intraoperative CT O-arm scans and analyzed using three-dimensional interactive viewing and manipulation of the images. The average caudal angle in the sagittal plane was 31.0° ± 10.0°. The average horizontal angle in the axial plane using the posterior superior iliac spine as a reference was 42.8° ± 6.6°. The average S1 screw to S2AI screw angle was 11.3° ± 9.9°. Two violations of the iliac cortex were noted, with an average breach distance of 7.9 ± 4.8 mm. One breach was posterior (2.2%) and one was anterior (2.2%). The overall robotic S2AI screw accuracy rate was 95.7%. There were no intraoperative neurologic, vascular, or visceral complications related to the placement of the S2AI screws. Spinopelvic fixation achieved using a bone-mounted miniature robotic-guided S2AI screw insertion technique is safe and reliable. Despite two breaches, no complications related to the placement of the S2AI screws occurred in this series. Level IV, therapeutic. Copyright © 2017 Scoliosis Research Society. Published by Elsevier

  15. Screw-worm eradication in the Americas - Overview

    International Nuclear Information System (INIS)

    Wyss, John H.

    2000-01-01

    media and techniques for screw-worm colonisation. In 1937, Knipling and Bushland began discussing an autocidal theory of screw-worm population suppression. These workers and others were studying screw-worms and developing treatment and control measures, but all work was suspended in 1937 because of the Second World War. Following the war, in 1947, interest once again turned to screw-worm control and eradication, and the development of what would become the sterile insect technique (SIT). Muller in 1950 described the effects of X-ray exposure on the reproductive system in Drosophila. Bushland and Hopkins in 1951 demonstrated that adult screw-worms of both sexes were sexually sterilised by irradiating the pupal stage of the insect. This promising work was field tested twice between 1951 and 1953 on Sanibel Island. Sanibel Island is a small island with an area of only 36 km 2 located 3 km off the southeast coast of Florida. In these first tests, 38 sterile males were used per km 2 on a weekly basis. The sterile flies were produced in the ARS Laboratory located at Kerrville, Texas. The results of the last field test were very encouraging. Sterile egg masses were detected the first week and within several weeks, 80 percent of the egg masses collected were sterile and the number of egg masses declined. The experiment was continued for several months, but screw-worms were not eradicated. This discouraging outcome was explained by the premise that the migration of fertile flies from the mainland was causing continuous re-infestations of the island. In 1954, this premise was tested in Curacao, West Indies. Here was an opportunity to test the sterile insect technique (SIT) on a 440 km 2 island located 65 km from the mainland of South America. On this island, they doubled the number of sterile males released from 38 to 76 per km 2 on a weekly basis. The sterile flies used in this experiment were produced at the facility at Bithlo, Florida. The results of this field test were very

  16. An optically sensed control rod drive system for use at the Nuclear Science Center Reactor

    International Nuclear Information System (INIS)

    Krohn, John L.; Fisher, Thomas H.

    1988-01-01

    The optically sensed rod drive control system, installed and modified at the NSCR is described. It has operated very well and has exhibited improved reliability over the previous system. The system has proven to give stable control rod positions, and the daily reset of the position indication serves to reduce the error between indicated and true rod position. The removal of the microswitches used for carriage up and carriage down indication in the previous system, and especially the 120 VAC motor control portion, has reduced the difficulty, time and uncertainty involved in upkeep of the system and also has removed a potentially dangerous source of personnel injury. As more operational experience is gained with this design, it is felt that other minor adjustments and logic changes may come about, but the present design of the system appears to be a successful and sufficient one

  17. Accuracy of computer-assisted cervicle pedicle screw installation

    International Nuclear Information System (INIS)

    Zhang Honglei; Zhou Dongsheng; Jang Zhensong

    2009-01-01

    Objective: To investigate the accuracy of computer-assisted cervical pedicle screw installation and the reason of screw malposition. Methods: A total of 172 cervical pedicle screws were installed by computer-assisted navigation for 30 patients with lower cervical spinal diseases. All the patients were examined by X-ray and CT after operation. Screw's position and direction were measured on the sagittal and transectional images of intraoperative navigation and post-operative CT. Then linear regression analysis was taken between navigational and post-operative CT's images. Results: Two screws perforated the upper pedicle wall, 3 perforated the lateral pedicle wall.There was a positive linear correlation between navigational and post-operative CT's images. Conclusion: Computer-assisted navigation can provide the high accuracy of cervical pedicle screw installation and excursion phenomenon is reason of screw malposition. (authors)

  18. Sucker rods

    Energy Technology Data Exchange (ETDEWEB)

    Rylov, B M; Kostur, I N; Shcheigiy, B I; Sukhanov, V S

    1983-01-01

    As an addendum to A.s. USSR patent No 769087, this particular sucker rod utilizes a differential piston spring that has been attached outside the body of the auxiliary pump. The pump cylinder is attached to the intake line of the main pump. The lower part of the auxiliary pump is equipped with vertical slits, while the differential piston is equipped with a perforated pusher and support under the spring; it can also be shifted as necessary with respect to the vertical slits.

  19. Dry rod consolidation technology development

    International Nuclear Information System (INIS)

    Rasmussen, T.L.; Schoonen, D.H.; Fisher, M.W.

    1986-01-01

    The Department of Energy's (DOE) Office of Civilian Radioactive Waste Management (OCRWM) is funding a Program to consolidate commercial spent fuel for testing in dry storage casks and to develop technology that will be fed into other OCRWM Programs, e.g., Prototypical Consolidation Demonstration Program. The Program is being conducted at the Idaho National Engineering Laboratory (INEL) by the Operating Contractor, EGandG Idaho, Inc. Hardware and software have been designed and fabricated for installation in a hot cell adjacent to the Test Area North (TAN) Hot Shop Facility. This equipment will be used to perform dry consolidation of commercial spent fuel from the Virginia Power (VP) Cooperative Agreement Spent Fuel Storage Cask (SPSC) Demonstration Program and assemblies that had previously been stored at the Engine Maintenance and Disassembly (EMAD) facility in Nevada. Consolidation will be accomplished by individual, horizontal rod pulling. A computerized semi-automatic control system with operator involvement will be utilized to conduct consolidation operations. Special features have been incorporated in the design to allow crud collection and measurement of rod pulling forces. During consolidation operations, data will be taken to characterize this technology. Still photo, video tape, and other documentation will be generated to make developed information available to interested parties. Cold checkout of the hardware and software will complete in September of 1986. Following installation in the hot cell, consolidation operations will begin in January 1987. Resulting consolidated fuel will be utilized in the VP Cooperative Agreement SFSC Program

  20. Method for verifying the pressure in a nuclear reactor fuel rod

    International Nuclear Information System (INIS)

    Jones, W.J.

    1979-01-01

    Disclosed is a method of accurately verifying the pressure contained in a sealed pressurized fuel rod by utilizing a pressure balance measurement technique wherein an end of the fuel rod extends through and is sealed in a wall of a small chamber. The chamber is pressurized to the nominal (desired) fuel rod pressure and the fuel rod is then pierced to interconnect the chamber and fuel rod. The deviation of chamber pressure is noted. The final combined pressure of the fuel rod and drill chamber is substantially equal to the nominal rod pressure; departure of the combined pressure from nominal is in direct proportion to departure of rod pressure from nominal. The maximum error in computing the rod pressure from the deviation of the combined pressure from nominal is estimated at plus or minus 3.0 psig for rod pressures within the specified production limits. If the rod pressure is corrected for rod void volume using a digital printer data record, the accuracy improves to about plus or minus 2.0 psig

  1. Comparison of Expansive Pedicle Screw and Polymethylmethacrylate-Augmented Pedicle Screw in Osteoporotic Sheep Lumbar Vertebrae: Biomechanical and Interfacial Evaluations

    OpenAIRE

    Liu, Da; Zhang, Yi; Zhang, Bo; Xie, Qing-yun; Wang, Cai-ru; Liu, Jin-biao; Liao, Dong-fa; Jiang, Kai; Lei, Wei; Pan, Xian-ming

    2013-01-01

    BACKGROUND: It was reported that expansive pedicle screw (EPS) and polymethylmethacrylate-augmented pedicle screw (PMMA-PS) could be used to increase screw stability in osteoporosis. However, there are no studies comparing the two kinds of screws in vivo. Thus, we aimed to compare biomechanical and interfacial performances of EPS and PMMA-PS in osteoporotic sheep spine. METHODOLOGY/PRINCIPAL FINDINGS: After successful induction of osteoporotic sheep, lumbar vertebrae in each sheep were random...

  2. Formation of rod-like nanostructure by aggregation of TiO2 ...

    Indian Academy of Sciences (India)

    rod-like nanoparticle aggregates was evaluated by the degradation of methylene blue ... Rod-like nanostructure; aligned nanoparticle aggregates; photocatalytic activity; antibacterial ... bioactive and electrical properties by effective utilization of light. Further TiO2 ... contact with microorganism as antimicrobial nanomaterials,.

  3. A computed tomographic anatomical study of the upper sacrum. Application for a user guide of pelvic fixation with iliosacral screws in adult spinal deformity.

    Science.gov (United States)

    Dubory, Arnaud; Bouloussa, Houssam; Riouallon, Guillaume; Wolff, Stéphane

    2017-12-01

    Widely used in traumatic pelvic ring fractures, the iliosacral (IS) screw technique for spino-pelvic fixation remains anecdotal in adult spinal deformity. The objective of this study was to assess anatomical variability of the adult upper sacrum and to provide a user guide of spino-pelvic fixation with IS screws in adult spinal deformity. Anatomical variability of the upper sacrum according to age, gender, height and weight was sought on 30 consecutive pelvic CT-scans. Thus, a user guide of spino-pelvic fixation with IS screws was modeled and assessed on ten CT-scans as described below. Two invariable landmarks usable during the surgical procedure were defined: point A (corresponding to the connector binding the IS screw to the spinal rod), equidistant from the first posterior sacral hole and the base of the S1 articular facet and 10 mm-embedded into the sacrum; point B (corresponding to the tip of the IS screw) located at the junction of the anterior third and middle third of the sacral endplate in the sagittal plane and at the middle of the endplate in the coronal plane. Point C corresponded to the intersection between the A-B direction and the external facet of the iliac wing. Three-dimensional reconstructions modeling the IS screw optimal direction according to the A-B-C straight line were assessed. Age had no effect on the anatomy of the upper sacrum. The distance between the base of the S1 superior articular facet and the top of the first posterior sacral hole was correlated with weight (r = 0.6; 95% CI [0.6-0.9]); p guide of spinopelvic fixation with IS screws seems to be reliable and reproducible independently of age, gender and morphologic characteristics but needs clinical assessment. Level IV.

  4. Control rod repositioning considerations in core design analysis

    International Nuclear Information System (INIS)

    Armstrong, B.C.; Buechel, R.J.

    1990-01-01

    Control rod repositioning is a method for minimizing rod cluster control assembly (RCCA) wear in the upper internals area where the guide cards interface with the rodlets of the RCCAs. A number of utilities have implemented strategies for rod repositioning, which often has no impact on the nuclear analysis for cases where the control rods are never repositioned into the active fuel. Other strategies involve repositioning the control rods several steps into the active fuel. The impact of this type of repositioning on the axial power shape and consequently the total peaking factor F Q T varies, depending on the method in which the repositioning is implemented at the plant. Operating for long periods with all the control and shutdown rods inserted several steps in the active fuel followed by withdrawing them fully from the core results in a shifting of the power distribution toward the top of the core and must be accounted for in the design analysis. On the other hand, an optional plan for control rod repositioning that considers margins available in related design parameters can be devised that minimizes the effects of the repositioning for the reload. This paper summarizes a rod repositioning strategy implemented for a recent reload and some calculated power shape results for this strategy and other scenarios

  5. Development of control system of coating of rod hydraulic cylinders

    Science.gov (United States)

    Aizhambaeva, S. Zh; Maximova, A. V.

    2018-01-01

    In this article, requirements to materials of hydraulic cylinders and methods of eliminating the main factors affecting the quality of the applied coatings rod hydraulic cylinders. The chromium plating process - one of ways of increase of anti-friction properties of coatings rods, stability to the wear and corrosion. The article gives description of differences of the stand-speed chromium plating process from other types of chromium plating that determines a conclusion about cutting time of chromium plating process. Conducting the analysis of technological equipment suggested addressing the modernization of high-speed chromium plating processes by automation and mechanization. Control system developed by design of schematic block diagram of a modernized and stand-speed chromium plating process.

  6. Fuel assembly for BWR type reactor

    International Nuclear Information System (INIS)

    Kato, Shigeru.

    1993-01-01

    In the fuel assembly of the present invention, a means for mounting and securing short fuel rods is improved. Not only long fuel rods but also short fuel rods are disposed in channel of the fuel assembly to improve reactor safety. The short fuel rods are supported by a screw means only at the lower end plug. The present invention prevents the support for the short fuel rod from being unreliable due to the slack of the screw by the pressure of inflowing coolants. That is, coolant abutting portions such as protrusions or concave grooves are disposed at a portion in the channel box where coolants flowing from the lower tie plate, as an uprising stream, cause collision. With such a constitution, a component caused by the pressure of the flowing coolants is formed. The component acts as a rotational moment in the direction of screwing the male threads of the short fuel rod into the end plug screw hole. Accordingly, the screw is not slackened, and the short fuel rods are mounted and secured certainly. (I.S.)

  7. Prototypical spent fuel rod consolidation equipment preliminary design report: Volume 1, Report

    International Nuclear Information System (INIS)

    1986-01-01

    This design report describes the NUS Preliminary Design of the Prototype Spent Nuclear Fuel Rod Consolidation Equipment for the Department of Energy. The sections of the report elaborate on each facet of the preliminary design. A concept summary is provided to assist the reader in rapidly understanding the complete design. The NUS Prototype Spent Fuel Rod Consolidation System is an automatically controlled system to consolidate a minimum of 750 MT (heavy metal)/year of US commercial nuclear reactor fuel, at 75% availability. The system is designed with replaceable components utilizing the latest state-of-the-art technology. This approach gives the system the flexibility to be developed without costly development programs, yet accept new technology as it evolves over the next ten years. Capability is also provided in the system design to accommodate a wide variety of fuel conditions and to recover from any situation which may arise

  8. Dorsal bridge plating or transarticular screws for Lisfranc fracture dislocations.

    Science.gov (United States)

    Kirzner, N; Zotov, P; Goldbloom, D; Curry, H; Bedi, H

    2018-04-01

    Aims The aim of this retrospective study was to compare the functional and radiological outcomes of bridge plating, screw fixation, and a combination of both methods for the treatment of Lisfranc fracture dislocations. Patients and Methods A total of 108 patients were treated for a Lisfranc fracture dislocation over a period of nine years. Of these, 38 underwent transarticular screw fixation, 45 dorsal bridge plating, and 25 a combination technique. Injuries were assessed preoperatively according to the Myerson classification system. The outcome measures included the American Orthopaedic Foot and Ankle Society (AOFAS) score, the validated Manchester Oxford Foot Questionnaire (MOXFQ) functional tool, and the radiological Wilppula classification of anatomical reduction. Results Significantly better functional outcomes were seen in the bridge plate group. These patients had a mean AOFAS score of 82.5 points, compared with 71.0 for the screw group and 63.3 for the combination group (p bridge plate group, 38.1 in the screw group, and 45.5 in the combination group (p bridge plating have better functional and radiological outcomes than those treated with transarticular screws or a combination technique. Cite this article: Bone Joint J 2018;100-B:468-74.

  9. Screw piles for cold climate foundations

    Energy Technology Data Exchange (ETDEWEB)

    Schmidt, R.; Sakr, M. [Almita Manufacturing Ltd., Edmonton, AB (Canada)

    2008-07-01

    Almita Manufacturing is an Alberta-based company that designs and builds screw piles with its own installation teams. It also engineers and supplies piles to numerous other companies and independent installers. The company services industries such as oil and gas; power transmission and distribution; and commercial construction. This presentation discussed the design and technical aspects of screw piles. A screw pile was defined as a steel pipe shaft with a 45 degree cut at the bottom and a formed helical plate welded to the outside of the pipe near the base and at a selected point on the shaft. The pile is screwed into the ground with a planetary drive head of suitable torque rating. The helical plate or helix helps facilitate the installation of the pile and gives the screw pile increased bearing capacity and pull-out resistance over a traditional straight-shaft pile. Screw piles were compared against cast in place concrete piles and steel driven piles. Screw piles were reported to have no tailings; no concrete curing time; no rebar, anchor belts, and no liners; and no dewatering. Screw piles can also be installed in all types of weather. Rhe Cree Burn Camp case study near Fort McMurray, Alberta was also presented. This residential camp and recreation complex consists of pre-fabricated units that make up three storey housing buildings and a single floor multi-use building. The case study provided information on soil; design parameter inputs; load testing program and pile configuration; geotechnical and structural design results; compression load test arrangement; pile test setup; and test results. The presentation also discussed fabrication as well as installation equipment. Various applications were also presented through a series of project pictures. Last, the presentation provided a simple cost analysis. tabs., figs.

  10. PWR FLECHT SEASET 21-rod bundle flow blockage task. Task plan report. FLECHT SEASET Program report No. 5

    International Nuclear Information System (INIS)

    Hochreiter, L.E.; Basel, R.A.; Dennis, R.J.; Lee, N.; Massie, H.W. Jr.; Loftus, M.J.; Rosal, E.R.; Valkovic, M.M.

    1980-10-01

    This report presents a descriptive plan of tests for the 21-Rod Bundle Flow Blockage Task of the Full-Length Emergency Cooling Heat Transfer Separate Effects and Systems Effects Test Program (FLECHT SEASET). This task will consist of forced and gravity reflooding tests utilizing electrical heater rods to simulate PWR nuclear core fuel rod arrays. All tests will be performed with a cosine axial power profile. These tests are planned to be used to determine effects of various flow blockage configurations (shapes and distributions) on reflooding behavior, to aid in development/assessment of computational models in predicting reflooding behavior of flow blockage configurations, and to screen flow blockage configurations for future 161-rod flow blockage bundle tests

  11. Prototypical Rod Consolidation Demonstration Project

    International Nuclear Information System (INIS)

    1993-05-01

    The objective of Phase III of the Prototypical Rod Consolidation Demonstration Project (PRCDP) was to procure, fabricate, assemble, and test the Prototypical Rod Consolidation System as described in the NUS Phase II Final Design Report. This effort required providing the materials, components, and fabricated parts which makes up all of the system equipment. In addition, it included the assembly, installation, and setup of this equipment at the Cold Test Facility. During the Phase III effort the system was tested on a component, subsystem, and system level. Volume IV provides the Operating and Maintenance Manual for the Prototypical Rod Consolidation System that was installed at the Cold Test Facility. This document, Book 4 of Volume IV, discusses: Off-normal operating and recovery procedures; Emergency response procedures; Troubleshooting procedures; and Preventive maintenance procedures

  12. Influence of screw holes and gamma sterilization on properties of phosphate glass fiber-reinforced composite bone plates.

    Science.gov (United States)

    Han, Na; Ahmed, Ifty; Parsons, Andrew J; Harper, Lee; Scotchford, Colin A; Scammell, Brigitte E; Rudd, Chris D

    2013-05-01

    Polymers prepared from polylactic acid (PLA) have found a multitude of uses as medical devices. For a material that degrades, the main advantage is that an implant would not necessitate a second surgical event for removal. In this study, fibers produced from a quaternary phosphate-based glass (PBG) in the system 50P2O5-40CaO-5Na2O-5Fe2O3 were used to reinforce PLA polymer. The purpose of this study was to assess the effect of screw holes in a range of PBG-reinforced PLA composites with varying fiber layup and volume fraction. The flexural properties obtained showed that the strength and modulus values increased with increasing fiber volume fraction; from 96 MPa to 320 MPa for strength and between 4 GPa and 24 GPa for modulus. Furthermore, utilizing a larger number of thinner unidirectional (UD) fiber prepreg layers provided a significant increase in mechanical properties, which was attributed to enhanced wet out and thus better fiber dispersion during production. The effect of gamma sterilization via flexural tests showed no statistically significant difference between the sterilized and nonsterilized samples, with the exception of the modulus values for samples with screw holes. Degradation profiles revealed that samples with screw holes degraded faster than those without screw holes due to an increased surface area for the plates with screw holes in PBS up to 30 days. Scanning electron microscope (SEM) analysis revealed fiber pullout before and after degradation. Compared with various fiber impregnation samples, with 25% volume fraction, 8 thinner unidirectional prepreg stacked samples had the shortest fiber pull-out lengths in comparison to the other samples investigated.

  13. A new palatal distractor device for bodily movement of maxillary bones by rigid self-locking miniplates and screws system.

    Science.gov (United States)

    Cortese, Antonio; Savastano, Mauro; Cantone, Antonio; Claudio, Pier Paolo

    2013-07-01

    A new palatal distractor device for bodily movement of the maxillary bones after complete segmented Le Fort I osteotomy for 1-stage transversal distraction and tridimensional repositioning on 1 patient is presented. The new distractor has an intrinsic tridimensional rigidity also in the fixation system by self-locking miniplates and screws for better control of the 2 maxillary fragments during distraction. Le Fort I distraction and repositioning procedure in association with a bilateral sagittal split osteotomy were performed on 1 patient with complete solution of the cross-bite and class III malocclusion. Results of dental and cephalometric analysis performed before surgery (T1), after surgery and distraction time (T2), and 18 months after surgery and orthodontic appliance removal (T3) are reported. No complications were encountered using the new distractor device. Advantages of this device and technique are presented including improved rigidity of both distraction (jackscrew) and fixation (4 self-locking miniplates and screws) systems resulting in complete control of the position of the 2 maxillary fragments during distraction and surgery. In addition, this new device allows resuming palatal distraction in the event of cross-bite relapse without causing dental-related problems or the risks of screw slackening.

  14. HCPWR type fuel elements design with respect to its control rods

    International Nuclear Information System (INIS)

    Abbate, M.J.; Sbaffoni, M.M.; Patino, N.E.; Torasso, O.

    1992-01-01

    The high conversion reactors (HCPWR) can improve the nuclear fuel utilization. One of its present problems is the optimization of the control rods' worth and its relationship with the void coefficient. This investigation means, starting from one reference's design, to analyze several possibilities on the number and distribution of the control rods. As main result, one design including 24 control rods in an optimized distribution, is recommended. (author)

  15. Complications of syndesmotic screw removal

    NARCIS (Netherlands)

    T. Schepers (Tim); E.M.M. van Lieshout (Esther); M.R. de Vries (Mark); M. van der Elst (Maarten)

    2011-01-01

    textabstractBackground: Currently, the metallic syndesmotic screw is the gold standard in the treatment of syndesmotic disruption. Whether or not this screw needs to be removed remains debatable. The aim of the current study was to determine the complications which occur following routine removal of

  16. Transient flow analysis of the single cylinder for the control rod hydraulic driving system

    International Nuclear Information System (INIS)

    Sun, Xinming; Qin, Benke; Bo, Hanliang

    2017-01-01

    Highlights: • The control rod hydraulic driving system(CRHDS) is a new type of built-in control rod drive technology. The hydraulic cylinder is the main component of the CRHDS. • Transient flow phenomenon in the CRHDS is studied by experiments under different working conditions. • The working mechanism of the hydraulic cylinder step motion and the key characteristic parameters are analyzed based on the experimental results. - Abstract: The control rod hydraulic driving system (CRHDS) is a new type of built-in control rod drive technology. In the CRHDS the pulse flow from the pump into the hydraulic cylinder of the control rod hydraulic drive mechanism (CRHDM) is regulated by the integrated valve to perform the step motion of the reactor control rod. Transient flow occurs in the CRHDS during control rod step motion process which is studied by experiments. The time-history curves of flow rate, pressure and inner cylinder displacement were analyzed, and the results show that the water hammer pressure peak during the step-up motion is high, while there are no obvious pressure fluctuations in the corresponding step-down motion. In the step-up process, the pressure fluctuation amplitude increases with the increase of CRHDS driving pressure. The step-up time and the pressure increasing time before step-up decreases with the driving pressure. The step-up pressure increases with the driving pressure. In the step-down process, the step-down time, the step-down pressure and the pressure decreasing time before step-down do not change with the increase of the driving pressure. The experimental results lay the base for the working principle and vibration reduction analysis of the CRHDS and it’s also helpful for improvement of the working performance of the key facilities and instruments of the CRHDS loop.

  17. A comparison of locked versus nonlocked Enders rods for length unstable pediatric femoral shaft fractures.

    Science.gov (United States)

    Ellis, Henry Bone; Ho, Christine A; Podeszwa, David A; Wilson, Philip L

    2011-12-01

    Stainless steel flexible Enders rods have been used for intramedullary fixation of pediatric femur fractures with good success. Despite intraoperative anatomic alignment, length unstable femur fractures can present postoperatively with fracture shortening. The purpose of this study was to review all length unstable pediatric femoral shaft fractures in which Enders rods were used and compare those that were locked to those that were not locked. A retrospective clinical and radiographic review of all patients at a single institution undergoing flexible intramedullary fixation for length unstable femoral shaft fractures from 2001 to 2008. A length unstable fracture was defined as either a comminuted fracture or a spiral fracture longer than twice the diameter of the femoral shaft. A total of 107 length unstable femoral shaft fractures fixed with Enders rods were identified, of which 37 cases (35%) had both Enders rods "locked" through the eyelet in the distal femur with a 2.7 mm fully threaded cortical screw. Patient demographics, clinical course, complications, fracture characteristics, and radiographic outcomes were compared for the locked and nonlocked groups. There were no statistical differences between the groups in demographic data, operative variables, fracture pattern, fracture location, time to union, femoral alignment, or major complications. Shortening of the femur and nail migration measured at 1 to 6 weeks postoperatively was significantly greater for the nonlocked cases. The medial and lateral locked Enders rods moved 1.3 and 1.9 mm, respectively, and the unlocked Enders each moved 12.1 mm (P < 0.05). At final follow-up there were significantly more (P < 0.05) clinical complaints in nonlocked group, including limp, clinical shortening, and painful palpable rods. Locking Enders rods for length unstable pediatric fractures is an excellent option to prevent shortening and resulted in no additional complications, added surgical time, or increased blood loss

  18. A power recirculating test rig for ball screw endurance tests

    Directory of Open Access Journals (Sweden)

    Giberti Hermes

    2016-01-01

    Full Text Available A conceptual design of an innovative test rig for endurance tests of ball screws is presented in this paper. The test rig layout is based on the power recirculating principle and it also allows to overtake the main critical issues of the ball screw endurance tests. Among these there are the high power required to make the test, the lengthy duration of the same and the high loads between the screw and the frame that holds it. The article describes the test rig designed scheme, the kinematic expedients to be adopted in order to obtain the required performance and functionality and the sizing procedure to choose the actuation system.

  19. Energy self-sufficient sensory ball screw drive; Energieautarker sensorischer Kugelgewindetrieb

    Energy Technology Data Exchange (ETDEWEB)

    Bertram, Oliver

    2012-07-01

    Nowadays the availability of machine tools plays a decisive role in competition to increase in productivity. From state of the art it arises, that ball screw drives are the most abusive component in feed drives because of abrasive wear. Furthermore condition monitoring enables avoiding unplanned machine failure and increasing the availability of the deployed production facility. Thereby the application of additional sensors allows the direct acquisition of wear correlative measurements. To reduce the required effort for integration and increase the robustness, reliability and clarity in industrial environment energy self-sufficient sensor systems can be applied. In this thesis the development and investigation of an energy self-sufficient sensory ball screw drive with direct measurement of wear correlative pretension for condition monitoring application is described. The prototype measures the pretension with force sensors based on strain gauges. The sensor system includes microcontroller-based electronics for signal processing as well as wireless data transmission with ZigBee-standard. A hybrid system assures the energy supply of the sensor system. On the one hand a stepper motor generator produces electrical energy from the motion energy of the ball screw drive. On the other hand an energy buffer based on super caps is reloaded in stationary position by wireless energy transmission. For verification a prototype system is build up. In measurements the sensory and energetic characteristics of the energy self-sufficient sensor systems are analyzed. Moreover, the functionality of the ball screw drive as well as the signal characteristics of the force sensors are examined for different pretensions. In addition, pretension losses due to wear are established in realized endurance trials, which means that timely maintenance can be planned.

  20. The effects of loading on the preload and dimensions of the abutment screw for a 3-unit cantilever-fixed prosthesis design.

    Science.gov (United States)

    Setia, Gaurav; Yousef, Hoda; Ehrenberg, David; Luke, Allyn; Weiner, Saul

    2013-08-01

    The purpose of this study was to use an in vitro model system to compare the effects on the screw torque and screw dimensions within 2 commercially available implant systems from occlusal loading on a cantilevered-fixed partial denture. Cantilevered implant-supported 3-unit prostheses with 2 premolar abutments and 1 premolar pontic (7.3 mm in length) were made on resin casts containing 2 implant analogs for 2 implant systems: BioLok Silhouette Tapered Implant System (Birmingham, AL) and Zimmer Tapered Screw-Vent Implant System (Carlsbad, CA) with 10 samples in each group. Each sample was loaded with either of 2 protocols: (1) a load of 50 N on the cantilevered pontic unit and (2) a loading of 150 N on all 3 units. The outcome measures were (1) changes in residual torque of the abutment screws and (2) changes in screw dimension. The BioLok Silhouette Tapered Implant group demonstrated slight but statistically significant torque loss 18.8% to 28.5% in both abutment screws for both protocols, P ≤ 0.05, without any changes in screw dimension. In the Zimmer Tapered Screw-Vent Implant group, there was a significant elongation of the abutment screws and a markedly significant 44.4%, (P ≤ 0.01) loss in torque in the mesial screw and a 28.5%, (P ≤ 0.05) loss in torque in the distal screw when the cantilever alone was loaded. Differences in screw design influence the maintenance of preload and distortion of the shank. The influence of the interface design, namely an internal hex of 1 mm versus an external hex did not influence the preload. Cantilevered prostheses can cause loss of torque and dimensional changes in abutment screws.

  1. Biomechanical competence of six different bone screws for reconstructive surgery in three different transplants: Fibular, iliac crest, scapular and artificial bone.

    Science.gov (United States)

    Pietsch, Arnold P; Raith, Stefan; Ode, Jan-Eric; Teichmann, Jan; Lethaus, Bernd; Möhlhenrich, Stephan C; Hölzle, Frank; Duda, Georg N; Steiner, Timm

    2016-06-01

    The goal of this study was to determine a combination of screw and transplantation type that offers optimal primary stability for reconstructive surgery. Fibular, iliac crest, and scapular transplants were tested along with artificial bone substrate. Six different kinds of bone screws (Medartis(©)) were compared, each type utilized with one of six specimens from human transplants (n = 6). Controlled screw-in-tests were performed and the required torque was protocolled. Subsequently, pull-out-tests were executed to determine the retention forces. The artificial bone substitute material showed significantly higher retention forces than real bone samples. The self-drilling screws achieved the significantly highest retention values in the synthetic bone substitute material. Cancellous screws achieved the highest retention in the fibular transplants, while self-drilling and cancellous screws demonstrated better retention than cortical screws in the iliac crest. In the scapular graft, no significant differences were found between the screw types. In comparison to the human transplant types, the cortical screws showed the significantly highest values in the fibula and the lowest values in the iliac crest. The best retention was found in the combination of cancellous screws with fibular graft (514.8 N + -252.3 N). For the flat bones (i.e., scapular and illiac crest) we recommend the cancellous screws. Copyright © 2016 European Association for Cranio-Maxillo-Facial Surgery. Published by Elsevier Ltd. All rights reserved.

  2. Enhancement of control rod drive mechanism seating position detector for JRR-3

    International Nuclear Information System (INIS)

    Ohuchi, Satoshi; Kurumada, Osamu; Kamiishi, Eigo; Sato, Masayuki; Ikekame, Yoshinori; Wada, Shigeru

    2016-06-01

    The purpose of the control rod drive mechanism seating position detector for JRR-3 is one of methods for confirming the shutdown condition of the reactor and sending out the seat position signal to other systems. The detector has been utilizing more than 25 years with maintenance regularly. However, some troubles occurred recently. Moreover, the detector has already been discontinued, and it is confirmed that the successor detector is unsuitable for the control rod drive mechanism of JRR-3. Therefore, it was necessary to select the adequate detector to the control rod drive mechanism of JRR-3. Accordingly, we built a test device with the aim of verifying several detectors for integrity and function. At the time of the test for performance confirmation, it was occurred unexpected problems. Nevertheless, we devise improvement of the problems and took measures. Thus we were able to make adequate detector for JRR-3 and replace to enhanced detector. This paper reports the Enhanced of Control rod drive mechanism seating position detector. (author)

  3. System for manipulating radioactive fuel rods within a nuclear fuel assembly

    International Nuclear Information System (INIS)

    Tolino, R.W.; King, W.E.; Blickenderfer, J.L.; Roth, C.H. Jr.

    1987-01-01

    A tool is described for manipulating the peripherally located fuel rods of a fuel assembly so that the rods can be visually inspected. The fuel assembly includes top and bottom nozzles, each of which is connected to a support skeleton, as well as grids, and wherein the rods are retained within the grids and confined between the top and bottom nozzles thereof. It consists of: (a) a fixture that is detachably connectable to one of the nozzles of the fuel assembly. The fixture having holes therein, (b) rotating means pivotally mountable within the holes of the fixture for selectively gripping and rotating the rod, and (c) a displacing means mounted on the fixture for reciprocably displacing the rods within the fuel assembly, including a lifting assembly and a push-down assembly for lifting and pushing down a selected one of the rods, respectively, whereby the rods can be selectively rotated, lifted, and pushed down in order to expose portions of the rods which are normally hidden to visual inspection while the nozzles stay connected to the support skeleton and the rods stay confined between the top and bottom nozzles of the fuel assembly

  4. Experimental study of the pressure discharge process for the hydraulic control rod drive system stepped cylinder

    International Nuclear Information System (INIS)

    Wang, Jinhua; Bo, Hanliang; Zheng, Wenxiang

    2002-01-01

    The pressure discharge process from the stepped cylinder of the Hydraulic Control Rod Drive System (HCRDS) was studied experimentally in the HCRDS experimental loop for the 200 MW Nuclear Heating Reactor (NHR-200). The results showed that the differential pressure between the outside and the inside of the stepped cylinder increased rapidly to the desired value so that the force induced by the differential pressure which pushes the out tube of stepped cylinder was large enough. Therefore, if the hydraulic control rod were jammed, the pressure could push the hydraulic control rod to overcome the frictional resistance to insert the control rod into the reactor core. The experimental results verified that this design would solve the problem of hydraulic control rod jamming during an accident. (author)

  5. Development of a high speed extrusion concept using a floating screw sleeve for solid-melt-separation

    Science.gov (United States)

    Karrenberg, Gregor; Wortberg, Johannes

    2015-05-01

    The High-Speed-S-Truder with floating screw sleeve is an alternative extrusion concept with solid-melt-separation. A fairly conventional 35 mm screw with a length of 21 D, which is accelerated by a 75 kW gearless, water cooled synchronous drive, conveys the resin into a 60 mm screw sleeve with a length of 10 D. Inside the sleeve the material is plasticizied and discharged into the outer screw channel of the sleeve through radial bores. Only the solid bed remains inside. The development of a melt pool - and thus a decrease of the plasticizing capacity - is avoided. The sleeve is rotated by drag forces only (approximately 10 - 15 % of the screw speed). Due to the low speed of the screw sleeve molten material is conveyed to a 4 D Dynamic Mixing Ring in a gentle manner. The DMRs floating ring and the screw sleeve are directly coupled. The granules in the screw channel are stopped by a barrier on the screw in front of the mixing device. So nearly no unmelted material can pass the system. For temperature management in the plastification and mixing zone a 3-zone heating/air-cooling system is used. Various kinds of experiments with the High-Speed S-Truder were conducted. Reachable throughputs with different types of material (LDPE, LLDPE, PP, PS) have been tested. Also three screw geometries, which are mainly varying in the channel depth, were compared. Experimental results and theoretical background will be described in this paper.

  6. Screw-vector bond graphs for kinetic-static modelling and analysis of mechanisms

    International Nuclear Information System (INIS)

    Bidard, Catherine

    1994-01-01

    This dissertation deals with the kinetic-static modelling and analysis of spatial mechanisms used in robotics systems. A framework is proposed, which embodies a geometrical and a network approach for kinetic-static modelling. For this purpose we use screw theory and bond graphs. A new form of bond graphs is introduced: the screw-vector bond graph, whose power variables are defined to be wrenches and twists expressed as intrinsic screw-vectors. The mechanism is then identified as a network, whose components are kinematic pairs and whose topology is described by a directed graph. A screw-vector Simple Junction Structure represents the topological constraints. Kinematic pairs are represented by one-port elements, defined by two reciprocal screw-vector spaces. Using dual bases of screw-vectors, a generic decomposition of kinematic pair elements is given. The reduction of kinetic-static models of series and parallel kinematic chains is used in order to derive kinetic-static functional models in geometric form. Thereupon, the computational causality assignment is adapted for the graphical analysis of the mobility and the functioning of spatial mechanisms, based on completely or incompletely specified models. (author) [fr

  7. SSYST, Modular System for Transient Fuel Rod Behaviour Under Accident Condition

    International Nuclear Information System (INIS)

    Gulden, W.; Meyder, R.; Borgwaldt, H.

    1987-01-01

    1 - Description of problem or function: SSYST is a code system for analyzing transient fuel rod behaviour under off-normal conditions, developed jointly by the Institut fuer Kernenergetik und Energie-systeme (IKE), Stuttgart, and Kernforschungszentrum Karlsruhe (KfK) under contract for the Projekt Nukleare Sicherheit (PNS) at KfK. Main differences versus codes with similar applications are: (1) an open-ended modular code organisation; (2) a preference for simple models, wherever possible. While feature (1) makes SSYST a very flexible tool, easily adapted to changing requirements, feature (2) leads to short execution times. The analysis of transient rod behaviour under LOCA boundary conditions takes 2 minutes CPU time on IBM 3033, so that extensive parametric studies are feasible. Main differences between SSYST-3 and previous versions are related to a general clean-up of the code system, which reduces the implementation effort: - advanced modules for cladding deformation and oxidation and reflooding conditions are included; - an input processor thoroughly checks all input data

  8. Vertical-Screw-Auger Conveyer Feeder

    Science.gov (United States)

    Walton, Otis (Inventor); Vollmer, Hubert J. (Inventor)

    2016-01-01

    A conical feeder is attached to a vertically conveying screw auger. The feeder is equipped with scoops and rotated from the surface to force-feed regolith the auger. Additional scoops are possible by adding a cylindrical section above the conical funnel section. Such then allows the unit to collect material from swaths larger in diameter than the enclosing casing pipe of the screw auger. A third element includes a flexible screw auger. All three can be used in combination in microgravity and zero atmosphere environments to drill and recover a wide area of subsurface regolith and entrained volatiles through a single access point on the surface.

  9. Control rod for FBR type reactor

    International Nuclear Information System (INIS)

    Nakai, Koichi.

    1993-01-01

    In a control rod for an LMFBR type reactor, a thermal resistor is disposed between a temperature sensitive cylinder and a cam unit support rod. A thermal expansion difference due to the temperature difference is caused between the temperature sensitive cylinder and the cam unit support rod only upon abrupt temperature change of coolants. A control rod shaft extending mechanism of downwardly depressing an absorbent portion by amplifying the thermal expansion difference by an extension link mechanism and the cam unit is provided. The thermal resistor comprises inconel 625 or like other steel of small heat conductivity. If a certain abnormality should cause to the reactor system to elevate the coolant temperature in the reactor elevates abruptly and the reactor shutdown system does not actuate, since the control rod extension shaft extends to urge the absorbent and lower the reactor core reactivity, so that leading to serious accident can be prevented surely. Further, the control rod extension shaft does not extend upon moderate temperature elevation in the usual startup and causes no unnecessary reactivity change. (N.H.)

  10. Optimization of spinal implant screw for lower vertebra through finite element studies.

    Science.gov (United States)

    Biswas, Jayanta; Karmakar, Santanu; Majumder, Santanu; Banerjee, Partha Sarathi; Saha, Subrata; Roychowdhury, Amit

    2014-01-01

    The increasing older population is suffering from an increase in age-related spinal degeneration that causes tremendous pain. Spine injury is mostly indicated at the lumbar spine (L3-L5) and corresponding intervertebral disks. Finite element analysis (FEA) is now one of the most efficient and accepted tools used to simulate these pathological conditions in computer-assisted design (CAD) models. In this study, L3-L5 spines were modeled, and FEA was performed to formulate optimal remedial measures. Three different loads (420, 490.5, and 588.6 N) based on three body weights (70, 90, and 120 kg) were applied at the top surface of the L3 vertebra, while the lower surface of the L5 vertebra remained fixed. Models of implants using stainless steel and titanium alloy (Ti6Al4V) pedicle screws and rods with three different diameters (4, 5, and 6 mm) were inserted into the spine models. The relative strengths of bone (very weak, weak, standard, strong, and very strong) were considered to determine the patient-specific effect. A total of 90 models were simulated, and von Mises stress and strain, shear stress, and strain intensity contour at the bone-implant interface were analyzed. Results of these analyses indicate that the 6-mm pedicle screw diameter is optimal for most cases. Experimental and clinical validation are needed to confirm these theoretical results.

  11. Control rod

    International Nuclear Information System (INIS)

    Igarashi, Takao; Sugawara, Satoshi; Yoshimoto, Yuichiro; Saito, Shozo; Fukumoto, Takashi.

    1987-01-01

    Purpose: To reduce the weight and thereby obtain satisfactory operationability of control rods by combining absorbing nuclear chain type neutron absorbers and conventional type neutron absorbers in the axial direction of blades. Constitution: Neutron absorber rods and long life type neutron absorber rods are disposed in a tie rod and a sheath. The neutron absorber rod comprises a poison tube made of stainless steels and packed with B 4 C powder. The long life type neutron absorber rod is prepared by packing B-10 enriched boron carbide powder into a hafnium metal rod, hafnium pipe, europium and stainless made poison tube. Since the long life type absorber rod uses HF as the absorbing nuclear chain type neutron absorber, it absorbs neutrons to form new neutron absorbers to increase the nuclear life. (Yoshino, Y.)

  12. Clinical accuracy of three-dimensional fluoroscopy (IsoC-3D)-assisted upper thoracic pedicle screw insertion

    International Nuclear Information System (INIS)

    Sugimoto, Yoshihisa; Ito, Yasuo; Shimokawa, Tetsuya; Shiozaki, Yasuyuki; Mazaki, Tetsuro; Tomioka, Masao; Tanaka, Masato

    2010-01-01

    Correct screw placement is especially difficult in the upper thoracic vertebrae. At the cervicothoracic junction (C7-T2), problems can arise because of the narrowness of the pedicle and the difficulty of using a lateral image intensifier there. Other upper thoracic vertebrae (T3-6) pose a problem for screw insertion also because of the narrower pedicle. We inserted 154 pedicle screws into 78 vertebrae (C7 to T6) in 38 patients. Screws were placed using intraoperative data acquisition by an isocentric C-arm fluoroscope (Siremobile Iso-C3D) and computer navigation. Out of 90 pedicle screws inserted into 45 vertebrae between C7 and T2, 87 of the 90 (96.7%) screws were classified as grade 1 (no perforation). Of 64 pedicle screws inserted into 33 vertebrae between T3 and T6, 61 of 64 (95.3%) screws were classified as grade 1. In this study, we reduced pedicle screw misplacement at the level of the C7 and upper thoracic (T1-6) vertebrae using the three-dimensional fluoroscopy navigation system. (author)

  13. Ion selectivity of the cation transport system of isolated intact cattle rod outer segments: evidence for a direct communication between the rod plasma membrane and the rod disk membranes.

    Science.gov (United States)

    Schnetkamp, P P

    1980-05-08

    The ion selectivity of cation transport through the plasma membrane of isolated intact cattle rod outer segments (rods) is investigated by means of 45Ca-exchange experiments and light-scattering experiments. These techniques appear to provide complementary information: the 45Ca experiments (45Ca fluxes in rods) describe electroneutral antiport, whereas the light-scattering experiments (shrinkage and swelling of rods upon hypertonic shocks with various electrolytes) reveal electrogenic uniport. Electroneutral symport of ions (salt transport) does not take place without addition of external ionophores and application of salts of weak acids. 1. Intact rods recover from a hypertonic shock in the presence of FCCP when lithium, sodium and potassium acetate are applied, but not when ammonium chloride, calcium and magnesium acetate are used. This indicates that the plasma membrane of isolated intact cattle rods is relatively permeable to net transport of Na+, Li+ and K+, and relatively impermeable to net transport of Cl-, Mg2+ and Ca2+ under conditions that do not give rise to diffusion potentials. 2. Rapid (t1/2 exchange diffusion of internal 45Ca with external Na+, Ca2+, Sr2+ and Ba2+, respectively. 3. All tested cations lower the rate of 45Ca uptake. The latter can be described by a single rate constant indicating a homogeneous rod preparation and a homogeneous endogenous Ca2+ pool. However, only those cations which stimulate 45Ca efflux from preloaded rods lower the final equilibrium of 45Ca uptake. Except for the effects of K+, Rb+ and Cs+ the reduction of the rate of 45Ca uptake by external cations appears to arise from competition for a common site on the plasms membrane. The observed affinities for this site do not correlate with actual transport (as indicated by the ability to stimulate 45Ca efflux). 4. K+ increases the affinity of the exchange diffusion system to Ca2+ from 1 microM to 0.15 microM and changes the relative affinities with respect to Ca2+ for the

  14. Calculating Characteristics of the Screws with Constant And Variable Step

    Directory of Open Access Journals (Sweden)

    B. N. Zotov

    2015-01-01

    Full Text Available This work is devoted to creating a technique for calculating power characteristics of the screws with constant and variable step for the centrifugal pumps. The technique feature is that the reverse currents, which are observed in screws working at low flow, are numerically taken into account. The paper presents a diagram of the stream in the screw with flow to the network Q=0, and the static pressure of the screw in this mode is computed according to reverse current parameters. Maximum flow of screw is determined from the known formulas. When calculating the power characteristics and computing the overall efficiency of the screw, for the first time a volumetric efficiency of the screw is introduced. It is defined as a ratio between the flow into the network and the sum of the reverse current flows and a flow into the network. This approach allowed us to determine the efficiency of the screw over the entire range of flows.A comparison of experimental characteristics of the constant step screw with those of calculated by the proposed technique shows their good agreement.The technique is also used in calculating characteristics of the variable step screws. The variable step screw is considered as a screw consisting of two screws with a smooth transition of the blades from the inlet to the outlet. Screws in which the step at the inlet is less than that of at the outlet as well as screws with the step at the inlet being more than that of at the outlet were investigated. It is shown that a pressure of the screw with zero step and the value of the reverse currents depend only on the parameters of the input section of the screw, and the maximum flow, if the step at the inlet is more than the step at the outlet, is determined by the parameters of the output part of the screw. Otherwise, the maximum flow is determined a little bit differently.The paper compares experimental characteristics with characteristics calculated by the technique for variable step

  15. Huitzoctli: A system to design Control Rod Pattern for BWR's using a hybrid method

    International Nuclear Information System (INIS)

    Castillo, Alejandro; Ortiz-Servin, Juan Jose; Perusquia, Raul; Morales, Luis B.

    2011-01-01

    Highlights: → The system was developed to design Control Rod Patterns for Boiling Water Reactors. → The critical reactor core and the thermal limits were fulfilled in all tested cases. → The Fuel Loading Pattern remains without changes during the iterative process. → The system uses the heuristics techniques: Scatter Search and Tabu Search. → The effective multiplication factor k eff at the EOC was improved in all tested cases. - Abstract: Huitzoctli system was developed to design Control Rod Patterns for Boiling Water Reactors (BWR). The main idea is to obtain a Control Rod Pattern under the following considerations: (a) the critical reactor core state is satisfied, (b) the axial power distribution must be adjusted to a target axial power distribution proposal, and (c) the maximum Fraction of Critical Power Ratio (MFLCPR), the maximum Fraction of Linear Power Density (FLPD) and the maximum Fraction of Average Planar Power Density (MPGR) must be fulfilled. Those parameters were obtained using the 3D CM-PRESTO code. In order to decrease the problem complexity, Control Cell Core load strategy was implemented; in the same way, intermediate axial positions and core eighth symmetry were took into account. In this work, the cycle length was divided in 12 burnup steps. The Fuel Loading Pattern is an input data and it remains without changes during the iterative process. The Huitzoctli system was developed to use the combinatorial heuristics techniques Scatter Search and Tabu Search. The first one was used as a global search method and the second one as a local search method. The Control Rod Patterns obtained with the Huitzoctli system were compared to other Control Rod Patterns designs obtained with other optimization techniques, under the same operating conditions. The results show a good performance of the system. In all cases the thermal limits were satisfied, and the axial power distribution was adjusted to the target axial power distribution almost

  16. Control rod calibration including the rod coupling effect

    International Nuclear Information System (INIS)

    Szilard, R.; Nelson, G.W.

    1984-01-01

    In a reactor containing more than one control rod, which includes all reactors licensed in the United States, there will be a 'coupling' or 'shadowing' of control rod flux at the location of a control rod as a result of the flux depression caused by another control rod. It was decided to investigate this phenomenon further, and eventually to put calibration table data or formulae in a small computer in the control room, so once could insert the positions of the three control rods and receive the excess reactivity without referring to separate tables. For this to be accomplished, a 'three control- rod reactivity function' would be used which would include the flux coupling between the rods. The function is design and measured data was fitted into it to determine the calibration constants. The input data for fitting the trial functions consisted of 254 data points, each consisting of the position of the reg, shim, and transient rods, and the total excess reactivity. (About 200 of these points were 'critical balance points', that is the rod positions for which reactor was critical, and the remainder were determined by positive period measurements.) Although this may be unrealistic from a physical viewpoint, the function derived gave a very accurate recalculation of the input data, and thus would faithfully give the excess reactivity for any possible combination of the locations of the three control rods. The next step, incorporation of the three-rod function into the minicomputer, will be pursued in the summer and fall of 1984

  17. Development of a control rod drive

    International Nuclear Information System (INIS)

    1991-01-01

    In the period under review, the computer codes required for transients calculation have been completed, as well as the programs for modelling and testing the hot-gas temperature control by means of combined core rod and reflector rod operation. The specification of requirements to be fulfilled by the rod drive computer and the neutron flux measuring system has been done relying essentially on the data obtained by the transients calculations performed and the resulting informations on operating conditions. The work for optimization of the core rod drive with regard to rod driving speeds and the 'three-point switch' with hysteresis for controlled, automatic core rod operation has been concentrating on the case of specified, normal operation of the reactor. (orig./DG) [de

  18. Prototypical Rod Consolidation Demonstration Project

    International Nuclear Information System (INIS)

    1993-05-01

    The objective of Phase 3 of the Prototypical Rod consolidation Demonstration Project (PRCDP) was to procure, fabricate, assemble, and test the Prototypical Rod consolidation System as described in the NUS Phase 2 Final Design Report. This effort required providing the materials, components, and fabricated parts which makes up all of the system equipment. In addition, it included the assembly, installation, and setup of this equipment at the Cold Test Facility. During the Phase 3 effort the system was tested on a component, subsystem, and system level. This volume 1, discusses the PRCDP Phase 3 Test Program that was conducted by the HALLIBURTON NUS Environmental Corporation under contract AC07-86ID12651 with the United States Department of Energy. This document, Volume 1, Book 2 discusses the following topics: Fuel Rod Extraction System Test Results and Analysis Reports and Clamping Table Test Results and Analysis Reports

  19. Implementation of a data fusion algorithm for RODS, a real-time outbreak and disease surveillance system.

    Energy Technology Data Exchange (ETDEWEB)

    Brown, Douglas (Sandia National Laboratories, Livermore, CA); Gray, Genetha Anne (Sandia National Laboratories, Livermore, CA)

    2005-10-01

    Due to the nature of many infectious agents, such as anthrax, symptoms may either take several days to manifest or resemble those of less serious illnesses leading to misdiagnosis. Thus, bioterrorism attacks that include the release of such agents are particularly dangerous and potentially deadly. For this reason, a system is needed for the quick and correct identification of disease outbreaks. The Real-time Outbreak Disease Surveillance System (RODS), initially developed by Carnegie Mellon University and the University of Pittsburgh, was created to meet this need. The RODS software implements different classifiers for pertinent health surveillance data in order to determine whether or not an outbreak has occurred. In an effort to improve the capability of RODS at detecting outbreaks, we incorporate a data fusion method. Data fusion is used to improve the results of a single classification by combining the output of multiple classifiers. This paper documents the first stages of the development of a data fusion system that can combine the output of the classifiers included in RODS.

  20. Simulation and operation of the EBR-II automatic control rod drive system

    International Nuclear Information System (INIS)

    Lehto, W.K.; Larson, H.A.; Dean, E.M.; Christensen, L.J.

    1985-01-01

    An automatic control rod drive system (ACRDS) installed at EBR-II produces shaped power transients from 40% to full reactor power at a linear ramp rate of 4 MWt/s. A digital computer and modified control-rod-drive provides this capability. Simulation and analysis of ACRDS experiments establish the safety envelope for reactor transient operation. Tailored transients are required as part of USDOE Operational Reliability Testing program for prototypic fast reactor fuel cladding breach behavior studies. After initial EBR-II driver fuel testing and system checkout, test subassemblies were subjected to both slow and fast transients. In addition, the ACRDS is used for steady-state operation and will be qualified to control power ascent from initial critical to full power

  1. Simulation and operation of the EBR-II automatic control rod drive system

    International Nuclear Information System (INIS)

    Lehto, W.K.; Larson, H.A.; Dean, E.M.; Christensen, L.J.

    1985-01-01

    An automatic control rod drive system (ACRDS) installed at EBR-II produces shaped power transients from 40% to full reactor power at a linear ramp rate of 4 MWt/s. A digital computer and modified control-rod-drive provides this capability. Simulation and analysis of ACRDS experiments establish the safety envelope for reactor transient operation. Tailored transients are required as part of USDOE Operational Reliability Testing program for prototypic fast reactor fuel cladding breach behavior studies. After initial EBR-II driver fuel testing and system checkout, test subassemblies were subjected to both slow and fast transients. In additions, the ACRDS is used for steady-state operation and will be qualified to control power ascent from initial critical to full power

  2. Titanium vs cobalt chromium: what is the best rod material to enhance adolescent idiopathic scoliosis correction with sublaminar bands?

    Science.gov (United States)

    Angelliaume, Audrey; Ferrero, E; Mazda, K; Le Hanneur, M; Accabled, F; de Gauzy, J Sales; Ilharreborde, B

    2017-06-01

    Cobalt chromium (CoCr) rods have recently gained popularity in adolescent idiopathic scoliosis (AIS) surgical treatment, replacing titanium (Ti) rods, with promising frontal correction rates in all-screw constructs. Posteromedial translation has been shown to emphasize thoracic sagittal correction, but the influence of rod material in this correction technique has never been investigated. The aim of this study was to compare the postoperative correction between Ti and CoCr rods for the treatment of thoracic AIS using posteromedial translation technique. 70 patients operated for thoracic (Lenke 1 or 2) AIS, in 2 institutions, between 2010 and 2013, were included. All patients underwent posterior fusion with hybrid constructs using posteromedial translation technique. The only difference between groups in the surgical procedure was the rod material (Ti or CoCr rods). Radiological measurements were compared preoperatively, postoperatively and at last follow-up (minimum 2 years). Preoperatively, groups were similar in terms of coronal and sagittal parameters. Postoperatively, no significant difference was observed between Ti and CoCr regarding frontal corrections, even when the preoperative flexibility of the curves was taken into account (p = 0.13). CoCr rods allowed greater restoration of T4T12 thoracic kyphosis, which remained stable over time (p = 0.01). Most common postoperative complication was proximal junctional kyphosis (n = 4). However, no significant difference was found between groups regarding postoperative complications rate. CoCr and Ti rods both provide significant and stable frontal correction in AIS treated with posteromedial translation technique using hybrid constructs. However, CoCr might be considered to emphasize sagittal correction in hypokyphotic patients.

  3. Insertion profiles of 4 headless compression screws.

    Science.gov (United States)

    Hart, Adam; Harvey, Edward J; Lefebvre, Louis-Philippe; Barthelat, Francois; Rabiei, Reza; Martineau, Paul A

    2013-09-01

    In practice, the surgeon must rely on screw position (insertion depth) and tactile feedback from the screwdriver (insertion torque) to gauge compression. In this study, we identified the relationship between interfragmentary compression and these 2 factors. The Acutrak Standard, Acutrak Mini, Synthes 3.0, and Herbert-Whipple implants were tested using a polyurethane foam scaphoid model. A specialized testing jig simultaneously measured compression force, insertion torque, and insertion depth at half-screw-turn intervals until failure occurred. The peak compression occurs at an insertion depth of -3.1 mm, -2.8 mm, 0.9 mm, and 1.5 mm for the Acutrak Mini, Acutrak Standard, Herbert-Whipple, and Synthes screws respectively (insertion depth is positive when the screw is proud above the bone and negative when buried). The compression and insertion torque at a depth of -2 mm were found to be 113 ± 18 N and 0.348 ± 0.052 Nm for the Acutrak Standard, 104 ± 15 N and 0.175 ± 0.008 Nm for the Acutrak Mini, 78 ± 9 N and 0.245 ± 0.006 Nm for the Herbert-Whipple, and 67 ± 2N, 0.233 ± 0.010 Nm for the Synthes headless compression screws. All 4 screws generated a sizable amount of compression (> 60 N) over a wide range of insertion depths. The compression at the commonly recommended insertion depth of -2 mm was not significantly different between screws; thus, implant selection should not be based on compression profile alone. Conically shaped screws (Acutrak) generated their peak compression when they were fully buried in the foam whereas the shanked screws (Synthes and Herbert-Whipple) reached peak compression before they were fully inserted. Because insertion torque correlated poorly with compression, surgeons should avoid using tactile judgment of torque as a proxy for compression. Knowledge of the insertion profile may improve our understanding of the implants, provide a better basis for comparing screws, and enable the surgeon to optimize compression. Copyright

  4. Ball Screw Actuator Including a Stop with an Integral Guide

    Science.gov (United States)

    Wingett, Paul T. (Inventor); Perek, John (Inventor); Geck, Kellan (Inventor)

    2015-01-01

    An actuator includes a housing assembly, a ball nut, a ball screw, and a ball screw stop. The ball nut is rotationally mounted in the housing assembly, is adapted to receive an input torque, and is configured, upon receipt thereof, to rotate and supply a drive force. The ball screw is mounted within the housing assembly and extends through the ball nut. The ball screw has a first end and a second end, and is coupled to receive the drive force from the ball nut. The ball screw is configured, upon receipt of the drive force, to selectively translate between a stow position and a deploy position. The ball screw stop is mounted on the ball screw to translate therewith and is configured to at selectively engage the housing assembly while the ball screw is translating, and engage the ball nut when the ball screw is in the deploy position.

  5. Environmental report for rod storage. Volume V

    International Nuclear Information System (INIS)

    Danese, F.L.

    1981-09-01

    Volume V of this report examines the environmental impact of the rod consolidation program. The postulated, nonsite-specific, differential impacts are primarily additional occupational exposures due to the rod storage operations. Other potential radiological and nonradiological impacts that are identified and addressed are negligible. There are no increases in population exposures except those associated with transportation of spent fuel and waste material. The increased utilization of existing spent fuel storage space could result in a decrease in the nonrecoverable material resources lost to new permanent spent fuel storage

  6. Validation of neutron flux redistribution factors in JSI TRIGA reactor due to control rod movements

    International Nuclear Information System (INIS)

    Kaiba, Tanja; Žerovnik, Gašper; Jazbec, Anže; Štancar, Žiga; Barbot, Loïc; Fourmentel, Damien; Snoj, Luka

    2015-01-01

    For efficient utilization of research reactors, such as TRIGA Mark II reactor in Ljubljana, it is important to know neutron flux distribution in the reactor as accurately as possible. The focus of this study is on the neutron flux redistributions due to control rod movements. For analyzing neutron flux redistributions, Monte Carlo calculations of fission rate distributions with the JSI TRIGA reactor model at different control rod configurations have been performed. Sensitivity of the detector response due to control rod movement have been studied. Optimal radial and axial positions of the detector have been determined. Measurements of the axial neutron flux distribution using the CEA manufactured fission chambers have been performed. The experiments at different control rod positions were conducted and compared with the MCNP calculations for a fixed detector axial position. In the future, simultaneous on-line measurements with multiple fission chambers will be performed inside the reactor core for a more accurate on-line power monitoring system. - Highlights: • Neutron flux redistribution due to control rod movement in JSI TRIGA has been studied. • Detector response sensitivity to the control rod position has been minimized. • Optimal radial and axial detector positions have been determined

  7. The influence of specific mechanical energy on cornmeal viscosity measured by an on-line system during twin-screw extrusion

    Directory of Open Access Journals (Sweden)

    Y. K. CHANG

    1999-09-01

    Full Text Available The influence of specific mechanical energy (SME on cornmeal viscosity during the twin-screw extrusion at feed moisture contents of 25 and 30% and screw speeds in the range from 100 to 500 rpm was measured. Cornmeal was extruded in a co-rotating, intermeshing twin-screw coupled to a slit die rheometer. One approach to the on-line rheological measurement is to use a slit die with the extruder. In the present work it was show that shear viscosity decreased as a function of SME. The viscosity of cornmeal at the exit die was influenced by screw speed, rate of total mass flow, mass temperature inside the extruder and SME. An increase in screw speed resulted in an increase in SME and a decrease in viscosity. A reduction in slit die height and an increase in screw speed and mass temperature led to a remarkable macromolecular degradation of the starch, as evidenced by the decrease in viscosity.

  8. Mini-Fragment Fixation Is Equivalent to Bicortical Screw Fixation for Horizontal Medial Malleolus Fractures.

    Science.gov (United States)

    Wegner, Adam M; Wolinsky, Philip R; Robbins, Michael A; Garcia, Tanya C; Amanatullah, Derek F

    2018-05-01

    Horizontal fractures of the medial malleolus occur through application of valgus or abduction force through the ankle that creates a tension failure of the medial malleolus. The authors hypothesize that mini-fragment T-plates may offer improved fixation, but the optimal fixation construct for these fractures remains unclear. Forty synthetic distal tibiae with identical osteotomies were randomized into 4 fixation constructs: (1) two parallel unicortical cancellous screws; (2) two parallel bicortical cortical screws; (3) a contoured mini-fragment T-plate with 2 unicortical screws in the fragment and 2 bicortical screws in the shaft; and (4) a contoured mini-fragment T-plate with 2 bicortical screws in the fragment and 2 unicortical screws in the shaft. Specimens were subjected to offset axial tension loading on a servohydraulic testing system and tracked using high-resolution video. Failure was defined as 2 mm of articular displacement. Analysis of variance followed by a Tukey-Kramer post hoc test was used to assess for differences between groups, with significance defined as Pfragment T-plate constructs (239±83 N/mm and 190±37 N/mm) and the bicortical screw construct (240±17 N/mm) were not statistically different. The mean stiffness values of both mini-fragment T-plate constructs and the bicortical screw construct were higher than that of a parallel unicortical screw construct (102±20 N/mm). Contoured T-plate constructs provide stiffer initial fixation than a unicortical cancellous screw construct. The T-plate is biomechanically equivalent to a bicortical screw construct, but may be superior in capturing small fragments of bone. [Orthopedics. 2018; 41(3):e395-e399.]. Copyright 2018, SLACK Incorporated.

  9. Ball Screw Actuator Including an Axial Soft Stop

    Science.gov (United States)

    Wingett, Paul T. (Inventor); Forrest, Steven Talbert (Inventor); Abel, Steve (Inventor); Woessner, George (Inventor); Hanlon, Casey (Inventor)

    2016-01-01

    An actuator includes an actuator housing, a ball screw, and an axial soft stop assembly. The ball screw extends through the actuator housing and has a first end and a second end. The ball screw is coupled to receive a drive force and is configured, upon receipt of the drive force, to selectively move in a retract direction and an extend direction. The axial soft stop assembly is disposed within the actuator housing. The axial soft stop assembly is configured to be selectively engaged by the ball screw and, upon being engaged thereby, to translate, with compliance, a predetermined distance in the extend direction, and to prevent further movement of the ball screw upon translating the predetermined distance.

  10. Control Rod Driveline Reactivity Feedback Model for Liquid Metal Reactors

    International Nuclear Information System (INIS)

    Kwon, Young-Min; Jeong, Hae-Yong; Chang, Won-Pyo; Cho, Chung-Ho; Lee, Yong-Bum

    2008-01-01

    The thermal expansion of the control rod drivelines (CRDL) is one important passive mitigator under all unprotected accident conditions in the metal and oxide cores. When the CRDL are washed by hot sodium in the coolant outlet plenum, the CRDL thermally expands and causes the control rods to be inserted further down into the active core region, providing a negative reactivity feedback. Since the control rods are attached to the top of the vessel head and the core attaches to the bottom of the reactor vessel (RV), the expansion of the vessel wall as it heats will either lower the core or raise the control rods supports. This contrary thermal expansion of the reactor vessel wall pulls the control rods out of the core somewhat, providing a positive reactivity feedback. However this is not a safety factor early in a transient because its time constant is relatively large. The total elongated length is calculated by subtracting the vessel expansion from the CRDL expansion to determine the net control rod expansion into the core. The system-wide safety analysis code SSC-K includes the CRDL/RV reactivity feedback model in which control rod and vessel expansions are calculated using single-nod temperatures for the vessel and CRDL masses. The KALIMER design has the upper internal structures (UIS) in which the CRDLs are positioned outside the structure where they are exposed to the mixed sodium temperature exiting the core. A new method to determine the CRDL expansion is suggested. Two dimensional hot pool thermal hydraulic model (HP2D) originally developed for the analysis of the stratification phenomena in the hot pool is utilized for a detailed heat transfer between the CRDL mass and the hot pool coolant. However, the reactor vessel wall temperature is still calculated by a simple lumped model

  11. Comparison of migration behavior between single and dual lag screw implants for intertrochanteric fracture fixation

    Directory of Open Access Journals (Sweden)

    Katonis Pavlos G

    2009-05-01

    Full Text Available Abstract Background Lag screw cut-out failure following fixation of unstable intertrochanteric fractures in osteoporotic bone remains an unsolved challenge. This study tested if resistance to cut-out failure can be improved by using a dual lag screw implant in place of a single lag screw implant. Migration behavior and cut-out resistance of a single and a dual lag screw implant were comparatively evaluated in surrogate specimens using an established laboratory model of hip screw cut-out failure. Methods Five dual lag screw implants (Endovis, Citieffe and five single lag screw implants (DHS, Synthes were tested in the Hip Implant Performance Simulator (HIPS of the Legacy Biomechanics Laboratory. This model simulated osteoporotic bone, an unstable fracture, and biaxial rocking motion representative of hip loading during normal gait. All constructs were loaded up to 20,000 cycles of 1.45 kN peak magnitude under biaxial rocking motion. The migration kinematics was continuously monitored with 6-degrees of freedom motion tracking system and the number of cycles to implant cut-out was recorded. Results The dual lag screw implant exhibited significantly less migration and sustained more loading cycles in comparison to the DHS single lag screw. All DHS constructs failed before 20,000 cycles, on average at 6,638 ± 2,837 cycles either by cut-out or permanent screw bending. At failure, DHS constructs exhibited 10.8 ± 2.3° varus collapse and 15.5 ± 9.5° rotation around the lag screw axis. Four out of five dual screws constructs sustained 20,000 loading cycles. One dual screw specimens sustained cut-out by medial migration of the distal screw after 10,054 cycles. At test end, varus collapse and neck rotation in dual screws implants advanced to 3.7 ± 1.7° and 1.6 ± 1.0°, respectively. Conclusion The single and double lag screw implants demonstrated a significantly different migration resistance in surrogate specimens under gait loading simulation with

  12. Electro-Optical Parameters Of Hairy Rod Polymer/Dimethylformamide System

    International Nuclear Information System (INIS)

    Spasevska, Hristina

    2003-01-01

    Rigid rod polymers are materials with special features, that is the reason why they have large scientific and technological applications like isotropic-nematic and other types of transition. One of the biggest problems that happen while investigation to these polymers, at molecular level, is their poor solubility in most of the common solvents. Solubility gets better if while synthesize junctions flexible side chains, [1]. Remaining polymers belong on one new class - hairy rod polymers and have big potential for their technological applications. Because of their nonlinear optical properties and opportunity for self-organization in super molecular structures (films and fibers), can be used in electronics and telecommunications industry either at display-technologies [2]. That is the main reason why controlling the remaining polymer features and connection of their microscopic and macroscopic characteristics, like an complete characterization (in solutions and solid state) is from essential scientific interest, actually it is an imperative. The polymer POD-2/that is subject of investigation, bellows to hairy rod polymers and it is synthesized for the first time [3] by giving a support to their characterization. Measures on diluted solutions from the system POD-2/dimethylformamide are made by the method electric birefringence, at three temperatures (25, 40 and 55 o C). For different concentrations on system, from obtained electro-optical signals (EOS), dependence on electric birefringence (Δn) against applied electric field (E 2 ), is determined. By investigation of electro-optical effects, especially studding the way of their maintenance and losing, while applying electric square impulses, relaxation time τ o of polymer molecules is calculated. From these parameters, as presented data for EOS rise and decay too, deformational electro-optical effect has been determined. (Author)

  13. A Biomechanical Analysis of 2 Constructs for Metacarpal Spiral Fracture Fixation in a Cadaver Model: 2 Large Screws Versus 3 Small Screws.

    Science.gov (United States)

    Eu-Jin Cheah, Andre; Behn, Anthony W; Comer, Garet; Yao, Jeffrey

    2017-12-01

    Surgeons confronted with a long spiral metacarpal fracture may choose to fix it solely with lagged screws. A biomechanical analysis of a metacarpal spiral fracture model was performed to determine whether 3 1.5-mm screws or 2 2.0-mm screws provided more stability during bending and torsional loading. Second and third metacarpals were harvested from 12 matched pairs of fresh-frozen cadaveric hands and spiral fractures were created. One specimen from each matched pair was fixed with 2 2.0-mm lagged screws whereas the other was fixed with 3 1.5-mm lagged screws. Nine pairs underwent combined cyclic cantilever bending and axial compressive loading followed by loading to failure. Nine additional pairs were subjected to cyclic external rotation while under a constant axial compressive load and were subsequently externally rotated to failure under a constant axial compressive load. Paired t tests were used to compare cyclic creep, stiffness, displacement, rotation, and peak load levels. Average failure torque for all specimens was 7.2 ± 1.7 Nm. In cyclic torsional testing, the group with 2 screws exhibited significantly less rotational creep than the one with 3 screws. A single specimen in the group with 2 screws failed before cyclic bending tests were completed. No other significant differences were found between test groups during torsional or bending tests. Both constructs were biomechanically similar except that the construct with 2 screws displayed significantly less loosening during torsional cyclic loading, although the difference was small and may not be clinically meaningful. Because we found no obvious biomechanical advantage to using 3 1.5-mm lagged screws to fix long spiral metacarpal fractures, the time efficiency and decreased implant costs of using 2-2.0 mm lagged screws may be preferred. Copyright © 2017 American Society for Surgery of the Hand. Published by Elsevier Inc. All rights reserved.

  14. Corks, screw caps and wine consumers of the Campanha Gaúcha

    Directory of Open Access Journals (Sweden)

    Fernandes Cordeiro Ataíde Israel

    2014-01-01

    Full Text Available The Campanha Gaúcha is a region the South of Brazil with a crescent production in fine wines. Corks or similar were the materials most utilized to seal the bottles, actually are utilized too screw caps. The objective of this research was investigated if the consumer of the Campanha considers the type of seal of the bottles at the moment of purchase. A questionnaire was elaborated and applied to seventy wine consumers, where was possible to measure the principals factors that lead these consumers to buy of bottle wine. Analyzed the data, referring the screw caps 45.71% believe that this type of seal is interesting just for young wines; As for sealing 85.71% considers indifferent the type of material to seal the bottle, because consider the variety and the price as the main factor in the buying decision; However, 14.29% of these consumers said just buy wines sealed by corks and similar. Therefore, despite the corks are linked with the culture of consumption of wine, exist a significant percentage of consumers that are more interested to purchase wines with a variety desired and with attractives prices, than specifically linked to type of seal.

  15. Accuracy of navigated pedicle screw insertion by a junior spine surgeon without spinal surgery experience

    International Nuclear Information System (INIS)

    Yamazaki, Hironori; Kotani, Toshiaki; Motegi, Hiroyuki; Nemoto, Tetsuharu; Koshi, Takana; Nagahara, Ken; Minami, Syohei

    2010-01-01

    The purpose of this study was to investigate pedicle screw placement accuracy during navigated surgery by a junior spine surgeon who had no spinal surgery experience. A junior spine surgeon with no spinal surgery experience implanted a total of 137 pedicle screws by using a navigation system. Postoperative computerized tomography was performed to evaluate screw placement, and the pedicle perforation rate was 2.2%. There were no neurologic or vascular complications related to the pedicle screws. The results demonstrated that pedicle screws can be placed safely and effectively by a junior spine surgeon who has no spinal surgery experience when instructed by a senior spine surgeon. The results of this study suggest that navigation can be used as a surgical training tool for junior spine surgeons. (author)

  16. Ultrasonics aids the identification of failed fuel rods

    International Nuclear Information System (INIS)

    Anon.

    1985-01-01

    Over a number of years Brown Boveri Reaktor of West Germany has developed and commercialized an ultrasonic failed fuel rod detection system. Sipping has up to now been the standard technique for failed fuel detection, but sipping can only indicate whether or not an assembly contains defective rods; the BBR system can tell which rod is defective. (author)

  17. Multispecies exclusion process with fusion and fission of rods: A model inspired by intraflagellar transport

    Science.gov (United States)

    Patra, Swayamshree; Chowdhury, Debashish

    2018-01-01

    We introduce a multispecies exclusion model where length-conserving probabilistic fusion and fission of the hard rods are allowed. Although all rods enter the system with the same initial length ℓ =1 , their length can keep changing, because of fusion and fission, as they move in a step-by-step manner towards the exit. Two neighboring hard rods of lengths ℓ1 and ℓ2 can fuse into a single rod of longer length ℓ =ℓ1+ℓ2 provided ℓ ≤N . Similarly, length-conserving fission of a rod of length ℓ'≤N results in two shorter daughter rods. Based on the extremum current hypothesis, we plot the phase diagram of the model under open boundary conditions utilizing the results derived for the same model under periodic boundary condition using mean-field approximation. The density profile and the flux profile of rods are in excellent agreement with computer simulations. Although the fusion and fission of the rods are motivated by similar phenomena observed in intraflagellar transport (IFT) in eukaryotic flagella, this exclusion model is too simple to account for the quantitative experimental data for any specific organism. Nevertheless, the concepts of "flux profile" and "transition zone" that emerge from the interplay of fusion and fission in this model are likely to have important implications for IFT and for other similar transport phenomena in long cell protrusions.

  18. Control rod drive

    International Nuclear Information System (INIS)

    Watando, Kosaku; Tanaka, Yuzo; Mizumura, Yasuhiro; Hosono, Kazuya.

    1975-01-01

    Object: To provide a simple and compact construction of an apparatus for driving a drive shaft inside with a magnetic force from the outside of the primary system water side. Structure: The weight of a plunger provided with an attraction plate is supported by a plunger lift spring means so as to provide a buffer action at the time of momentary movement while also permitting the load on lift coil to be constituted solely by the load on the drive shaft. In addition, by arranging the attraction plate and lift coil so that they face each other with a small gap there-between, it is made possible to reduce the size and permit efficient utilization of the attracting force. Because of the small size, cooling can be simply carried out. Further, since there is no mechanical penetration portion, there is no possibility of leakage of the primary system water. Furthermore, concentration of load on a latch pin is prevented by arranging so that with a structure the load of the control rod to be directly beared through the scrum latch. (Kamimura, M.)

  19. Metallurgical analysis of a failed maraging steel shear screw used in the band separation system of a satellite launch vehicle

    Directory of Open Access Journals (Sweden)

    S.V.S. Narayana Murty

    2016-10-01

    Full Text Available Maraging steels have excellent combination of strength and toughness and are extensively used for a variety of aerospace applications. In one such critical application, this steel was used to fabricate shear screws of a stage separation system in a satellite launch vehicle. During assembly preparations, one of the shear screws which connected the separation band and band end block has failed at the first thread. Microstructural analysis revealed that the crack originated from the root of the thread and propagated in an intergranular mode. The failure is attributed to combined effect of stress and corrosion leading to stress corrosion cracking.

  20. Stress corrosion cracking lifetime prediction of spring screw

    International Nuclear Information System (INIS)

    Koh, S. K.; Ryu, C. H.

    2004-01-01

    A lifetime prediction of holddown spring screw in nuclear fuel assembly was performed using fracture mechanics approach. The spring screw was designed such that it was capable of sustaining the loads imposed by the initial tensile preload and operational loads. In order to investigate the cause of failure and to predict the stress corrosion cracking life of the screw, a stress analysis of the top nozzle spring assembly was done using finite element analysis. The elastic-plastic finite element analysis showed that the local stresses at the critical regions of head-shank fillet and thread root significantly exceeded than the yield strength of the screw material, resulting in local plastic deformation. Normalized stress intensity factors for PWSCC life prediction was proposed. Primary water stress corrosion cracking life of the Inconel 600 screw was predicted by using integration of the Scott model and resulted in 1.78 years, which was fairly close to the actual service life of the holddown spring screw

  1. Magnesium Alloys as a Biomaterial for Degradable Craniofacial Screws

    Science.gov (United States)

    Henderson, Sarah E.; Verdelis, Konstantinos; Maiti, Spandan; Pal, Siladitya; Chung, William L.; Chou, Da-Tren; Kumta, Prashant N.; Almarza, Alejandro J.

    2014-01-01

    Recently, magnesium (Mg) alloys have received significant attention as a potential biomaterial for degradable implants, and this study was directed at evaluating the suitability of Mg for craniofacial bone screws. The objective was to implant screws fabricated from commercially available Mg-alloys (pure Mg and AZ31) in-vivo in a rabbit mandible. First, Mg-alloy screws were compared to stainless steel screws in an in-vitro pull-out test and determined to have a similar holding strength (~40N). A finite element model of the screw was created using the pull-out test data, and the model can be used for future Mg-alloy screw design. Then, Mg-alloy screws were implanted for 4, 8, and 12 weeks, with two controls of an osteotomy site (hole) with no implant and a stainless steel screw implanted for 12 weeks. MicroCT (computed tomography) was used to assess bone remodeling and Mg-alloy degradation, both visually and qualitatively through volume fraction measurements for all time points. Histologic analysis was also completed for the Mg-alloys at 12 weeks. The results showed that craniofacial bone remodeling occurred around both Mg-alloy screw types. Pure Mg had a different degradation profile than AZ31, however bone growth occurred around both screw types. The degradation rate of both Mg-alloy screw types in the bone marrow space and the muscle were faster than in the cortical bone space at 12 weeks. Furthermore, it was shown that by alloying Mg, the degradation profile could be changed. These results indicate the promise of using Mg-alloys for craniofacial applications. PMID:24384125

  2. Control rod selecting and driving device

    International Nuclear Information System (INIS)

    Isobe, Hideo.

    1981-01-01

    Purpose: To simultaneously drive a predetermined number of control rods in a predetermined mode by the control of addresses for predetermined number of control rods and read or write of driving codified data to and from the memory by way of a memory controller. Constitution: The system comprises a control rod information selection device for selecting predetermined control rods from a plurality of control rods disposed in a reactor and outputting information for driving them in a predetermined mode, a control rod information output device for codifying the information outputted from the above device and outputting the addresses to the predetermined control rods and driving mode coded data, and a driving device for driving said predetermined control rods in a predetermined mode in accordance with the codified data outputted from the above device, said control rod infromation output device comprising a memory device capable of storing a predetermined number of the codified data and a memory control device for storing the predetermined number of data into the above memory device at a predetermined timing while successively outputting the thus stored predetermined number of data at a predetermined timing. (Seki, T.)

  3. Control rod drive mechanism

    International Nuclear Information System (INIS)

    Mizuno, Katsuyuki.

    1976-01-01

    Object: To restrict the reduction in performance due to stress corrosion cracks by making use of condensate produced in a turbine steam condenser. Structure: Water produced in a turbine steam condenser is forced into a condensed water desalting unit by low pressure condensate pump. The condensate is purified and then forced by a high pressure condensate pump into a feedwater heater for heating before it is returned to the reactor by a feedwater pump. Part of the condensate issuing from the condensate desalting unit is branched from the remaining portion at a point upstream the pump and is withdrawn into a control rod drive water pump after passing through a motordriven bypass valve, an orifice and a condenser water level control valve, is pressurized in the control rod drive water desalting unit and supplied to a control rod drive water pressure system. The control rod is vertically moved by the valve operation of the water pressure system. Since water of high oxygen concentration does not enter during normal operation, it is possible to prevent the stress cracking of the stainless steel apparatus. (Nakamura, S.)

  4. Robust technology and system for management of sucker rod pumping units in oil wells

    Science.gov (United States)

    Aliev, T. A.; Rzayev, A. H.; Guluyev, G. A.; Alizada, T. A.; Rzayeva, N. E.

    2018-01-01

    We propose a technology for calculating the robust, normalized correlation functions of the signal from the force sensor on the rod string attached to the hanger of the sucker rod pumping unit. The robust normalized correlation functions are used to form sets of informative attribute combinations, each of which corresponds to a technical condition of the sucker rod pumping unit. We demonstrate how these sets can be used to solve identification and management problems in the oil production process in real time using inexpensive controllers. The results obtained from using the system on real objects are also presented in this paper. It was determined that the energy saved and prolonged overhaul period substantially increased the cost-effectiveness.

  5. Vortex Noise from Rotating Cylindrical Rods

    Science.gov (United States)

    Stowell, E Z; Deming, A F

    1935-01-01

    A series of round rods of the some diameter were rotated individually about the mid-point of each rod. Vortices are shed from the rods when in motion, giving rise to the emission of sound. With the rotating system placed in the open air, the distribution of sound in space, the acoustical power output, and the spectral distribution have been studied. The frequency of emission of vortices from any point on the rod is given by the formula von Karman. From the spectrum estimates are made of the distribution of acoustical power along the rod, the amount of air concerned in sound production, the "equivalent size" of the vortices, and the acoustical energy content for each vortex.

  6. Clinical efficacy of bone cement injectable pedicle screw system combined with intervertebral fusion in treatment of lumbar spondylolysis and osteoporosis

    Directory of Open Access Journals (Sweden)

    Peng-yi DAI

    2016-10-01

    Full Text Available Objective  To observe the therapeutic effect of bone cement injectable pedicle screw system combined with intervertebral fusion for lumbar spondylolysis and osteoporosis. Methods  The clinical data were analyzed retrospectively of 21 patients with lumbar spondylolysis and osteoporosis who received treatment of bone cement injectable pedicle screw system and intervertebral fusion from Aug. 2013 to Nov. 2015. The 21 patients (9 males and 12 females aged from 60 to 80 years (mean 64 years old; 6 of them presented degenerative spondylolysis, 15 with isthmic spondylolisthesis; 2 cases had I degree slippage, 13 had Ⅱdegree slippage, 6 had Ⅲdegree slippage, and all the cases were unisegmental slippage including 9 cases in L4 and 12 cases in L5. Bone mineral density of lumbar vertebrae (L2-L5 was measured with dual-energy X-ray absorptiometry, and T values conforming to the diagnostic criteria of osteoporosis were less than or equal to -2.5; All patients were operated with whole lamina resection for decompression, bone cement injectable pedicle screws system implantation, propped open reduction and fixation intervertebral fusion. The clinical outcomes were determined by the radiographic evaluation including intervertebral height, height of intervertebral foramen, slip distance, slip rate and slip angle, and Oswestry disability index (ODI on preoperative, 3 months after operation and the end of the time, and the interbody fusion were followed up. Results  Cerebrospinal fluid leakage of incision was observed in two cases after operation, compression and dressing to incision, Trendelenburg position, dehydration and other treatments were taken, and the stitches of incisions were taken out on schedule. Slips in the 21 patients were reset to different extent, and lumbar physiological curvatures were recovered. The intervertebral height and height of intervertebral foramen were obviously higher 3 months after operation than that before operation (P0

  7. Prototypical Rod Consolidation Demonstration Project

    International Nuclear Information System (INIS)

    1993-05-01

    The objective of Phase 3 of the Prototypical Rod consolidation Demonstration Project (PRCDP) was to procure, fabricate, assemble, and test the Prototypical Rod consolidation System as described in the NUS Phase 2 Final Design Report. This effort required providing the materials, components, and fabricated parts which makes up all of the system equipment. In addition, it included the assembly, installation, and setup of this equipment at the Cold Test Facility. During the Phase 3 effort the system was tested on a component, subsystem, and system level. This volume 1, discusses the PRCDP Phase 3 Test Program that was conducted by the HALLIBURTON NUS Environmental Corporation under contract AC07-86ID12651 with the United States Department of Energy. This document, Volume 1, Book 4 discusses the following topics: Rod Compaction/Loading System Test Results and Analysis Report; Waste Collection System Test Results and Analysis Report; Waste Container Transfer Fixture Test Results and Analysis Report; Staging and Cutting Table Test Results and Analysis Report; and Upper Cutting System Test Results and Analysis Report

  8. Considerations about the utilization of electrically heated rods used for simulation of nuclear fuel pins

    International Nuclear Information System (INIS)

    Lima, R. de C.F. de; Carajilescov, P.

    1987-01-01

    The dinamic behavior of electrically heated rods used for simulation of nuclear fuel pins in nuclear power transients, is analysed by the application of the lumped parameter and the finite difference methods. Deviations of the rods surface conditions, for extreme accidental transient conditions are presented and discussed. (author) [pt

  9. Tightening techniques for the retaining screws of universal abutment

    Directory of Open Access Journals (Sweden)

    Alexandre Wittcinski REGALIN

    Full Text Available Abstract Purpose This study evaluated the torque maintenance of universal abutment retaining screws using different tightening techniques, and coated or uncoated screws. Material and method The screws were tightened to implants as following: Control – 32 Ncm torque; H20 – holding 32 Ncm torque for 20 s; R – 32 Ncm torque, repeated after 10 min (retorque; and H20+R – combining the two tightening techniques. Titanium and coated screws were also evaluated. Result Statistical analysis showed higher maintained torque for titanium screws (p<0.001. The H20+R technique showed the highest maintained torque (p=0.003, but the H20 technique’s maintained torque was similar. Conclusion Titanium screws associating the two tightening techniques can improve maintained torque.

  10. Operational experience gained with the failed fuel rod detection system in nuclear power plants

    International Nuclear Information System (INIS)

    Boehm, H.H.; Forch, H.

    1985-01-01

    Brown Boveri Reaktor GmbH together with Krautkramer Company developed such a FAILED FUEL ROD DETECTION SYSTEM (FFRDS) which allows to located defective fuel rods without dismantling the fuel assembly or pulling of individual rods. Since 1979 the FFRDS is employed successfully in various nuclear power plants in Europe, USA, Japan, and Korea. The short inspection time and the high reliability of the method make the FFRDS a true competitor to the sipping method. In this paper the authors discuss the method and the design of the system, the equipment set-up, its features and the experience gained so far. The system has been performed and automated to such an extent that within a short installation period series of fuel assemblies can be tested with relatively short intervals of time (5 minutes for BWR and 7 minutes for PWR fuel assemblies per side). The ability of the system for deployment under various conditions and the experience gained during the past six years have made this system universally applicable and highly sensitive to the requirements of NDT during outages and for transport of FAs to intermediate storage facilities. Comparison of FFRDS to conventional sipping has indicated in several instances that the FFRDS is superior to the latter technique

  11. Control rod drives

    International Nuclear Information System (INIS)

    Nakamura, Akira.

    1984-01-01

    Purpose: To enable to monitor the coupling state between a control rod and a control rod drive. Constitution: After the completion of a control rod withdrawal, a coolant pressure is applied to a control rod drive being adjusted so as to raise only the control rod drive and, in a case where the coupling between the control rod drive and the control rod is detached, the former is elevated till it contacts the control rod and then stopped. The actual stopping position is detected by an actual position detection circuit and compared with a predetermined position stored in a predetermined position detection circuit. If both of the positions are not aligned with each other, it is judged by a judging circuit that the control rod and the control rod drives are not combined. (Sekiya, K.)

  12. On-line fuel and control rod integrity management in BWRs

    International Nuclear Information System (INIS)

    Larsson, Irina; Sihver, Lembit

    2011-01-01

    Surveillance of fuel and control rod integrity in a BWR core is essential to maintain a safe and reliable operation of a nuclear power plant. An accurate and prompt way to monitor fuel integrity in a reactor core during reactor operation is by using on-line measurements of the gamma emitting noble gas activities in the off-gas system. The integrity of control rods can be efficiently followed by on-line measurements of the helium (He) concentration in the off-gases. This method also gives information about fuel rod failures since He is used as a fill gas in the fuel rods. To survey fuel and control rod integrity during reactor operation, a system consisting of combined gamma and He on-line measurements in the off-gases should be used. Such a system can detect and follow the behavior of fuel and control rod failures. In addition, it can separate fuel failures from control rod failures since fuel rods contain both He and gamma emitting noble gases, while control rods only contain He. Moreover, the system is able to distinguish primary fuel failures from degradation of already existing ones. In this paper we present a combined system for on-line measurements of He and gamma emitting noble gases in the reactor off-gas system and measuring experiences from different BWRs. (author)

  13. Method for compacting spent nuclear reactor fuel rods

    International Nuclear Information System (INIS)

    Wachter, W.J.

    1988-01-01

    In a nuclear reactor system which requires periodic physical manipulation of spent fuel rods, the method of compacting fuel rods from a fuel rod assembly is described. The method consists of: (1) removing the top end from the fuel rod assembly; (2) passing each of multiple fuel rod pulling elements in sequence through a fuel rod container and thence through respective consolidating passages in a fuel rod directing chamber; (3) engaging one of the pulling elements to the top end of each of the fuel rods; (4) drawing each of the pulling elements axially to draw the respective engaged fuel rods in one axial direction through the respective the passages in the chamber to thereby consolidate the fuel rods into a compacted configuration of a cross-sectional area smaller than the cross-sectional area occupied thereby within the fuel rod assembly; and (5) drawing all of the engaged fuel rods concurrently and substantially parallel to one another in the one axial direction into the fuel rod container while maintaining the compacted configuration whereby the fuel rods are aligned within the container in a fuel rod density of the the fuel rod assembly

  14. The Free-Hand Technique for S2-Alar-Iliac Screw Placement: A Safe and Effective Method for Sacropelvic Fixation in Adult Spinal Deformity.

    Science.gov (United States)

    Shillingford, Jamal N; Laratta, Joseph L; Tan, Lee A; Sarpong, Nana O; Lin, James D; Fischer, Charla R; Lehman, Ronald A; Kim, Yongjung J; Lenke, Lawrence G

    2018-02-21

    Spinopelvic fixation is an integral part of achieving solid fusion across the lumbosacral junction, especially in deformity procedures requiring substantial correction or long-segment constructs. Traditional S2-alar-iliac (S2AI) screw-placement techniques utilize fluoroscopy, increasing operative time and radiation exposure to the patient and surgeon. We describe a novel free-hand technique for S2AI screw placement in patients with adult spinal deformity. We reviewed the records of 45 consecutive patients who underwent spinopelvic fixation performed with use of S2AI screws by the senior surgeon and various fellows or residents over a 12-month period (2015 to 2016). In each case, the S2AI screws were placed utilizing a free-hand technique without fluoroscopic or image guidance. Screw position and accuracy were assessed by intraoperative O-arm imaging and analyzed using 3-dimensional interactive manipulation of computed tomography images. A total of 100 screws were placed, 51 by the senior surgeon and 49 by trainees. The mean patient age was 57.4 ± 12.7 years at the time of surgery; 37 (82.2%) of the patients were female. Preoperative diagnoses included adult idiopathic scoliosis (n = 19), adult degenerative scoliosis (n = 15), flatback syndrome (n = 2), fixed sagittal imbalance (n = 6), and distal junctional kyphosis (n = 3). Five (5%) of the screws were placed with moderate to severe cortical breaches, all of which perforated the pelvis posteriorly, with no clinically notable neurovascular or visceral complications. The breach rate did not differ significantly between the senior surgeon and trainees. The free-hand technique for S2AI screw placement, when performed in a standardized manner, was demonstrated to be safe and reliable in constructs requiring spinopelvic fixation. The accuracy of screw placement relies on visible and palpable anatomic landmarks that obviate the need for intraoperative fluoroscopy or image guidance, potentially reducing operative time

  15. Fabrication of control rod system of RSG-GAS

    International Nuclear Information System (INIS)

    Hari-Sudirdjo; Setyono; Hendra-Prasetya

    2003-01-01

    Two unit absorbers, they are part of RSG-GAS control rod system, have been fabricated. One set absorber consist of two absorber plates and absorber casing. Absorber plate is made of Ag In Cd ( 80%, 15%, 5% ) alloy, which is cladded by stainless steel plate SS-316. Ag In Cd absorber plate has size of 625 mm x 60 mm x 3.3 mm, while cladding plat has thickness of 0.8 mm. Fabrication of two set absorbers has been conducted according to the plan

  16. Do screws and screw holes affect osteolysis in cementless cups using highly crosslinked polyethylene? A 7 to 10-year follow-up case-control study.

    Science.gov (United States)

    Taniguchi, N; Jinno, T; Takada, R; Koga, D; Ando, T; Okawa, A; Haro, H

    2018-05-01

    The use of screws and the presence of screw holes may cause acetabular osteolysis and implant loosening in cementless total hip arthroplasty (THA) using conventional polyethylene. In contrast, this issue is not fully understood using highly crosslinked polyethylene (HXLPE), particularly in large comparative study. Therefore, we performed a case-control study to assess the influence of screw usage and screw holes on: (1) implant fixation and osteolysis and (2) polyethylene steady-state wear rate, using cases with HXLPE liners followed up for 7-10 years postoperatively. The screw usage and screw holes adversely affect the implant fixation and incidence of wear-related osteolysis in THA with HXLPE. We reviewed 209 primary cementless THAs performed with 26-mm cobalt-chromium heads on HXLPE liners. To compare the effects of the use of screws and the presence of screw holes, the following groups were established: (1) with-screw (n=140); (2) without-screw (n=69); (3) no-hole (n=27) and (4) group in which a cup with screw holes, but no screw was used (n=42). Two adjunct groups (no-hole cups excluded) were established to compare the differences in the two types of HXLPE: (5) remelted group (n=100) and (6) annealed group (n=82). Implant stability and osteolysis were evaluated by plain radiography and computed tomography. The wear rate from 1 year to the final evaluation was measured using plain X-rays and PolyWare Digital software. All cups and stems achieved bony fixation. On CT-scan, no acetabular osteolysis was found, but there were 3 cases with a small area of femoral osteolysis. The mean steady-state wear rate of each group was (1) 0.031±0.022, (2) 0.033±0.035, (3) 0.031±0.024, (4) 0.029±0.018, (5) 0.030±0.018 and (6) 0.034±0.023mm/year, respectively. A comparison of the effects of screw usage or screw holes found no significant between-group differences in the implant stability, prevalence of osteolysis [no acetabular osteolysis and 3/209 at femoral side (1

  17. Automatic system of welding for nuclear fuel rods

    International Nuclear Information System (INIS)

    Romero G, M; Romero C, J.

    1998-01-01

    The welding process of nuclear fuel must be realized in an inert gas environment (He) and constant flow of this. In order to reach these conditions it is necessary to do vacuum at the chamber and after it is pressurized with the noble gas (purge) twice in the welding chamber. The purge eliminates impurities that can provoke oxidation in the weld. Once the conditions for initiating the welding are gotten, it is necessary to draw a graph of the flow parameters, pressure, voltage and arc current and to analyse those conditions in which have been carried out the weld. The rod weld must be free of possible pores or cracks which could provoke rod leaks, so reducing the probability of these failures should intervene mechanical and metallurgical factors. Automatizing the process it allows to do reliable welding assuring that conditions have been performed, reaching a high quality welding. Visually it can be observed the welding process by means of a mimic which represents the welding system. There are the parameters acquired such as voltage, current, pressure and flow during the welding arc to be analysed later. (Author)

  18. Development of embedded Control System for Control and Safety Rod Drive Mechanisms (CSRDMs) of PFBR

    International Nuclear Information System (INIS)

    Kameswari, K.; Palanisami, K.; Thirugnana Murthy, D.; Murali, N.; Satyamurty, S.A.V.

    2013-01-01

    Prototype Fast Breeder Reactor (PFBR), a 500 MWe, Sodium cooled, fast breeder reactor is nearing completion at Kalpakkam, Tamil Nadu. PFBR has two independent, fast acting and diverse shutdown systems, one with nine Control and Safety Rods (CSRs) and another with three Diverse Safety Rods (DSRs), with independent driving mechanisms called CSRDMs and DSRDMs respectively. This paper deals with the development of Real Time Computer based Control system for controlling nine CSRDMs with model based software development environment - SCADE (Safety Critical Application Development Environment). (author)

  19. A geometrical introduction to screw theory

    International Nuclear Information System (INIS)

    Minguzzi, E

    2013-01-01

    This work introduces screw theory, a venerable but little known theory aimed at describing rigid body dynamics. This formulation of mechanics unifies in the concept of screw the translational and rotational degrees of freedom of the body. It captures a remarkable mathematical analogy between mechanical momenta and linear velocities, and between forces and angular velocities. For instance, it clarifies that angular velocities should be treated as applied vectors and that, under the composition of motions, they sum with the same rules of applied forces. This work provides a short and rigorous introduction to screw theory intended for an undergraduate and general readership. (paper)

  20. Twin screw wet granulation: Binder delivery.

    Science.gov (United States)

    Saleh, Mohammed F; Dhenge, Ranjit M; Cartwright, James J; Hounslow, Michael J; Salman, Agba D

    2015-06-20

    The effects of three ways of binder delivery into the twin screw granulator (TSG) on the residence time, torque, properties of granules (size, shape, strength) and binder distribution were studied. The binder distribution was visualised through the transparent barrel using high speed imaging as well as quantified using offline technique. Furthermore, the effect of binder delivery and the change of screw configuration (conveying elements only and conveying elements with kneading elements) on the surface velocity of granules across the screw channel were investigated using particle image velocimetry (PIV). The binder was delivered in three ways; all solid binder incorporated with powder mixture, 50% of solid binder mixed with powder mixture and 50% mixed with water, all the solid binder dissolved in water. Incorporation of all solid binder with powder mixture resulted in the relatively longer residence time and higher torque, narrower granule size distribution, more spherical granules, weaker big-sized granules, stronger small-sized granules and better binder distribution compared to that in other two ways. The surface velocity of granules showed variation from one screw to another as a result of uneven liquid distribution as well as shown a reduction while introducing the kneading elements into the screw configuration. Copyright © 2015. Published by Elsevier B.V.

  1. Biomechanical comparison of 3.0 mm headless compression screw and 3.5 mm cortical bone screw in a canine humeral condylar fracture model.

    Science.gov (United States)

    Gonsalves, Mishka N; Jankovits, Daniel A; Huber, Michael L; Strom, Adam M; Garcia, Tanya C; Stover, Susan M

    2016-09-20

    To compare the biomechanical properties of simulated humeral condylar fractures reduced with one of two screw fixation methods: 3.0 mm headless compression screw (HCS) or 3.5 mm cortical bone screw (CBS) placed in lag fashion. Bilateral humeri were collected from nine canine cadavers. Standardized osteotomies were stabilized with 3.0 mm HCS in one limb and 3.5 mm CBS in the contralateral limb. Condylar fragments were loaded to walk, trot, and failure loads while measuring construct properties and condylar fragment motion. The 3.5 mm CBS-stabilized constructs were 36% stiffer than 3.0 mm HCS-stabilized constructs, but differences were not apparent in quality of fracture reduction nor in yield loads, which exceeded expected physiological loads during rehabilitation. Small residual fragment displacements were not different between CBS and HCS screws. Small fragment rotation was not significantly different between screws, but was weakly correlated with moment arm length (R² = 0.25). A CBS screw placed in lag fashion provides stiffer fixation than an HCS screw, although both screws provide similar anatomical reduction and yield strength to condylar fracture fixation in adult canine humeri.

  2. Control rod assembly

    International Nuclear Information System (INIS)

    Takahashi, Akio.

    1982-01-01

    Purpose: To enable reliable insertion and drops of control rods, as well as insure a sufficient flow rate of coolants flowing through the control rods for attaining satisfactory cooling thereof to enable relexation of thermal stress resulted to rectifying mechanisms or the likes. Constitution: To the outer circumference of a control rod contained vertically movably within a control rod guide tube, resistive members are retractably provided in such a way as to project to close the gap between outer circumference of the control rod and the inner surface of the control rod guide tube upon engagement of a gripper of control rod drives, and retract upon release of the engagement of the gripper. Thus, since the resistive members project to provide a greater resistance to the coolants flowing between them and the control rod guide tube in the normal operation where the gripper is engaged to drive the control rod by the control rod drives, a major part of the coolant flowing into the control rod guide tube flows into the control rod. This enables to cool the control rod effectively and make the temperature distribution uniform for the coolant flowing from the upper end of the control rod guide tube to thereby attain the relaxation of the thermal stress resulted in the rectifying mechanisms or the likes. (Moriyama, K.)

  3. Device for coupling a control rod and control rod drive

    International Nuclear Information System (INIS)

    Nishioka, Kazuya.

    1975-01-01

    Object: To obtain simple and reliable coupling between a control rod and control rod drive by equipping the lower end of the control rod with an extension provided with lateral protuberances and forming the upper end of an index tube with a recess provided with lateral holes. Structure: The tapering central extension of the control rod is inserted into the recess by lowering the control rod, and then it is further inserted by causing frictional movement of the inclined surfaces of lateral protuberances in frictional contact with guide surfaces. When the lateral protuberances are brought into contact with a stepped portion, the control rod is rotated to fit the lateral protuberances into the lateral holes. In this way, the control rod is coupled to the index tube of the control rod drive. (Yoshino, Y.)

  4. Development of structural schemes of parallel structure manipulators using screw calculus

    Science.gov (United States)

    Rashoyan, G. V.; Shalyukhin, K. A.; Gaponenko, EV

    2018-03-01

    The paper considers the approach to the structural analysis and synthesis of parallel structure robots based on the mathematical apparatus of groups of screws and on a concept of reciprocity of screws. The results are depicted of synthesis of parallel structure robots with different numbers of degrees of freedom, corresponding to the different groups of screws. Power screws are applied with this aim, based on the principle of static-kinematic analogy; the power screws are similar to the orts of axes of not driven kinematic pairs of a corresponding connecting chain. Accordingly, kinematic screws of the outlet chain of a robot are simultaneously determined which are reciprocal to power screws of kinematic sub-chains. Solution of certain synthesis problems is illustrated with practical applications. Closed groups of screws can have eight types. The three-membered groups of screws are of greatest significance, as well as four-membered screw groups [1] and six-membered screw groups. Three-membered screw groups correspond to progressively guiding mechanisms, to spherical mechanisms, and to planar mechanisms. The four-membered group corresponds to the motion of the SCARA robot. The six-membered group includes all possible motions. From the works of A.P. Kotelnikov, F.M. Dimentberg, it is known that closed fifth-order screw groups do not exist. The article presents examples of the mechanisms corresponding to the given groups.

  5. Comparison of 3D displacements of screw-retained zirconia implant crowns into implants with different internal connections with respect to screw tightening.

    Science.gov (United States)

    Rebeeah, Hanadi A; Yilmaz, Burak; Seidt, Jeremy D; McGlumphy, Edwin; Clelland, Nancy; Brantley, William

    2018-01-01

    Internal conical implant-abutment connections without horizontal platforms may lead to crown displacement during screw tightening and torque application. This displacement may affect the proximal contacts and occlusion of the definitive prosthesis. The purpose of this in vitro study was to evaluate the displacement of custom screw-retained zirconia single crowns into a recently introduced internal conical seal implant-abutment connection in 3D during hand and torque driver screw tightening. Stereolithic acrylic resin models were printed using computed tomography data from a patient missing the maxillary right central incisor. Two different internal connection implant systems (both ∼11.5 mm) were placed in the edentulous site in each model using a surgical guide. Five screw-retained single zirconia computer-aided design and computer-aided manufacturing (CAD-CAM) crowns were fabricated for each system. A pair of high-resolution digital cameras was used to record the relationship of the crown to the model. The crowns were tightened according to the manufacturers' specifications using a torque driver, and the cameras recorded their relative position again. Three-dimensional image correlation was used to measure and compare crown positions, first hand tightened and then torque driven. The displacement test was repeated 3 times for each crown. Commercial image correlation software was used to extract the data and compare the amount of displacement vertically, mesiodistally, and buccolingually. Repeated-measures ANOVA calculated the relative displacements for all 5 specimens for each implant for both crown screw hand tightening and after applied torque. A Student t test with Bonferroni correction was used for pairwise comparison of interest to determine statistical differences between the 2 implants (α=.05). The mean vertical displacements were statistically higher than the mean displacements in the mesiodistal and buccolingual directions for both implants

  6. Virtual surgery simulation versus traditional approaches in training of residents in cervical pedicle screw placement.

    Science.gov (United States)

    Hou, Yang; Shi, Jiangang; Lin, Yanping; Chen, Huajiang; Yuan, Wen

    2018-06-01

    The cervical screw placement is one of the most difficult procedures in spine surgery, which often needs a long period of repeated practices and could cause screw placement-related complications. We performed this cadaver study to investigate the effectiveness of virtual surgical training system (VSTS) on cervical pedicle screw instrumentation for residents. A total of ten novice residents were randomly assigned to two groups: the simulation training (ST) group (n = 5) and control group (n = 5). The ST group received a surgical training of cervical pedicle screw placement on VSTS and the control group was given an introductory teaching session before cadaver test. Ten fresh adult spine specimens including 6 males and 4 females were collected, and were randomly allocated to the two groups. The bilateral C3-C6 pedicle screw instrumentation was performed in the specimens of the two groups, respectively. After instrumentation, screw positions of the two groups were evaluated by image examinations. There was significantly statistical difference in screw penetration rates between the ST (10%) and control group (62.5%, P VSTS as an advanced training tool exhibited promising effects on improving performance of novice residents in cervical pedicle screw placement compared with the traditional teaching methods.

  7. Piston rod seal for a Stirling engine

    Science.gov (United States)

    Shapiro, Wilbur

    1984-01-01

    In a piston rod seal for a Stirling engine, a hydrostatic bearing and differential pressure regulating valve are utilized to provide for a low pressure differential across a rubbing seal between the hydrogen and oil so as to reduce wear on the seal.

  8. Computerized supervision and control system for movement at the RP-10 reactor control rods bank

    International Nuclear Information System (INIS)

    Padilla M, C.E.

    1998-01-01

    The project involves the use of a compatible microcomputer, Labwindows/CVI software, as well as National Instruments data acquisition cards AT-MIO16-E10 and PC-DIO96 to modify the sequence of movement of the reactor's rods and control them from a graphic interface in a computer's monitor. This graphic presentation is set as console of virtual instruments from where rod movement can be conducted. Normal rod movement, bank rod movement, and rod calibration have been considered. These experiences involve different logic of rod movements, which will determine movement sequence. Control of the automatic range of a current amplifier module was also considered. This module is know as 'automatic pilot amplifier' and given the strategic location of its detector (compensated ionizing camera) at the reactor's core, it delivers neutron flux current considered as reference to superficial neutron flux distribution at the reactor's core. Lecture and monitoring of this signal allows taking the reactor to a certain power, current of this signal is proportional to the power we want the reactor to reach. Advantages obtained with this system include the update of the control console, more uniform distribution of neutron flux, with lower and uniform burnup of nuclear fuel. (author)

  9. Experiment monitoring system of a new electromagnet drive for nuclear reactor control rod

    International Nuclear Information System (INIS)

    Zhang Jige; Wang Xiaoguang; Wu Yuanqiang; Zhang Zhengming

    2003-01-01

    In order to deal with some unsolved problems in the engineering prototype design of a new electromagnet drive device for nuclear reactor control rod, the property experiment in view of principle prototype is carried out. Actual displacement of nuclear reactor control rod is measured by means of raster ruler and the test data is obtained by means of computer. The computer communicates with PLC using RS232 serial port. The experimental results show that the monitoring system have the properties of high reliability and high precision, and ensures the experiment to accomplish successfully

  10. Control rod driving mechanism

    International Nuclear Information System (INIS)

    Ooshima, Yoshio.

    1983-01-01

    Purpose: To perform reliable scram operation, even if abnormality should occur in a system instructing scram operation in FBR type reactors. Constitution: An aluminum alloy member to be melt at a predetermined temperature (about 600sup(o)C) is disposed to a connection part between a control rod and a driving mechanism, whereby the control rod is detached from the driving mechanism and gravitationally fallen to the reactor core. (Ikeda, J.)

  11. Status of rod consolidation, 1988

    International Nuclear Information System (INIS)

    Bailey, W.J.

    1989-01-01

    It is estimated that the spent fuel storage pools at some domestic light-water reactors will run out of space before 2003, the year that the US Department of Energy currently predicts it will have a repository available. Of the methods being studied to alleviate the problem, rod consolidation is one of the leading candidates for achieving more efficient use of existing space in spent fuel storage pools. Rod consolidation involves mechanically removing all the fuel rods from the fuel assembly hardware (i.e., the structural components) and placing the fuel rods in a close-packed array in a canister without space grids. A typical goal of rod consolidation systems is to insert the fuel rods from two fuel assemblies into a canister that has the same exterior dimensions as one standard fuel assembly (i.e., to achieve a consolidation or compaction ratio of 2:1) and to compact the nonfuel-bearing structural components from those two fuel assemblies by a factor of 10 to 20. This report provides an overview of the current status of rod consolidation in the United States and a small amount of information on related activities in other countries. 85 refs., 36 figs., 5 tabs

  12. Control rod position detection device

    International Nuclear Information System (INIS)

    Akita, Haruo; Ogiwara, Sakae.

    1996-01-01

    The device of the present invention is used in a back-up shut down system of an LMFBR type reactor which is easy for maintenance, has high reliability and can recognize the position of control rods accurately. Namely, a permanent magnet is disposed to a control rod extension tube connected to the lower portion of the control rod. The detector guide tube is disposed in the vicinity of the control rod extension tube. A detector having a detection coil is inserted into a detector tube. With such constitution, the control rod can be detected at one position using the following method. (1) the movement of the magnetic field of the permanent magnet is detected by the detection coil. (2) a plurality of grooves are formed on the control rod extension tube, and the movement of the grooves is detected. In addition, the detection coil is inserted into the detector guide tube, and the signals from the detection coil are inputted to a signal processing circuit disposed at the outside of the reactor vessel using an MI cable to enable the maintenance of the detector. Further, if the detector comprises a detection coil and an excitation coil, the position of a dropped control rod can be recognized at a plurality of points. (I.S.)

  13. Control rod displacement

    International Nuclear Information System (INIS)

    Nakazato, S.

    1987-01-01

    This patent describes a nuclear reactor including a core, cylindrical control rods, a single support means supporting the control rods from their upper ends in spaced apart positions and movable for displacing the control rods in their longitudinal direction between a first end position in which the control rods are fully inserted into the core and a second end position in which the control rods are retracted from the core, and guide means contacting discrete regions of the outer surface of each control rod at least when the control rods are in the vicinity of the second end position. The control rods are supported by the support means for longitudinal movement without rotation into and out of the core relative to the guide means to thereby cause the outer surface of the control rods to experience wear as a result of sliding contact with the guide means. The support means are so arranged with respect to the core and the guide means that it is incapable of rotation relative to the guide means. The improvement comprises displacement means being operatively coupled to a respective one of the control rods for periodically rotating the control rod in a single angular direction through an angle selected to change the locations on the outer surfaces of the control rods at which the control rods are contacted by the guide means during subsequent longitudinal movement of the control rods

  14. Chirality-controlled crystallization via screw dislocations.

    Science.gov (United States)

    Sung, Baeckkyoung; de la Cotte, Alexis; Grelet, Eric

    2018-04-11

    Chirality plays an important role in science from enantiomeric separation in chemistry to chiral plasmonics in nanotechnology. However, the understanding of chirality amplification from chiral building blocks to ordered helical superstructures remains a challenge. Here, we demonstrate that topological defects, such as screw dislocations, can drive the chirality transfer from particle to supramolecular structure level during the crystallization process. By using a model system of chiral particles, which enables direct imaging of single particle incorporation into growing crystals, we show that the crystallization kinetic pathway is the key parameter for monitoring, via the defects, the chirality amplification of the crystalline structures from racemic to predominantly homohelical. We provide an explanation based on the interplay between geometrical frustration, racemization induced by thermal fluctuations, and particle chirality. Our results demonstrate that screw dislocations not only promote the growth, but also control the chiral morphology and therefore the functionality of crystalline states.

  15. Biomechanics of Posterior Dynamic Fusion Systems in the Lumbar Spine: Implications for Stabilization With Improved Arthrodesis.

    Science.gov (United States)

    Yu, Alexander K; Siegfried, Catherine M; Chew, Brandon; Hobbs, Joseph; Sabersky, Abraham; Jho, Diana J; Cook, Daniel J; Bellotte, Jonathan Brad; Whiting, Donald M; Cheng, Boyle C

    2016-08-01

    A comparative biomechanical human cadaveric spine study of a dynamic fusion rod and a traditional titanium rod. The purpose of this study was to measure and compare the biomechanical metrics associated with a dynamic fusion device, Isobar TTL Evolution, and a rigid rod. Dynamic fusion rods may enhance arthrodesis compared with a rigid rod. Wolff's law implies that bone remodeling and growth may be enhanced through anterior column loading (AL). This is important for dynamic fusion rods because their purpose is to increase AL. Six fresh-frozen lumbar cadaveric specimens were used. Each untreated specimen (Intact) underwent biomechanical testing. Next, each specimen had a unilateral transforaminal lumbar interbody fusion performed at L3-L4 using a cage with an integrated load cell. Pedicle screws were also placed at this time. Subsequently, the Isobar was implanted and tested, and finally, a rigid rod replaced the Isobar in the same pedicle screw arrangement. In terms of range of motion, the Isobar performed comparably to the rigid rod and there was no statistical difference found between Isobar and rigid rod. There was a significant difference between the intact and rigid rod and also between intact and Isobar conditions in flexion extension. For interpedicular displacement, there was a significant increase in flexion extension (P=0.017) for the Isobar compared with the rigid rod. Isobar showed increased AL under axial compression compared with the rigid rod (P=0.024). Isobar provided comparable stabilization to a rigid rod when using range of motion as the metric, however, AL was increased because of the greater interpedicular displacement of dynamic rod compared with a rigid rod. By increasing interpedicular displacement and AL, it potentially brings clinical benefit to procedures relying on arthrodesis.

  16. CT provides precise size assessment of implanted titanium alloy pedicle screws.

    Science.gov (United States)

    Elliott, Michael J; Slakey, Joseph B

    2014-05-01

    After performing instrumented spinal fusion with pedicle screws, postoperative imaging using CT to assess screw position may be necessary. Stainless steel implants produce significant metal artifact on CT, and the degree of distortion is at least partially dependent on the cross-sectional area of the implanted device. If the same effect occurs with titanium alloy implants, ability to precisely measure proximity of screws to adjacent structures may be adversely affected as screw size increases. We therefore asked whether (1) CT provides precise measurements of true screw widths; and (2) precision degrades based on the size of the titanium implant imaged. CT scans performed on 20 patients after instrumented spinal fusion for scoliosis were reviewed. The sizes of 151 titanium alloy pedicle screws were measured and compared with known screw size. The amount of metal bloom artifact was determined for each of the four screw sizes. ANOVA with Tukey's post hoc test were performed to evaluate differences in scatter, and Spearman's rho coefficient was used to measure relationship between screw size and scatter. All screws measured larger than their known size, but even with larger 7-mm screws the size differential was less than 1 mm. The four different screw sizes produced scatter amounts that were different from each other (p titanium alloy pedicle screws produces minimal artifact, thus making this the preferred imaging modality to assess screw position after surgery. Although the amount of artifact increases with the volume of titanium present, the degree of distortion is minimal and is usually less than 1 mm.

  17. Fate of the syndesmotic screw--Search for a prudent solution.

    Science.gov (United States)

    Kaftandziev, Igor; Spasov, Marko; Trpeski, Simon; Zafirova-Ivanovska, Beti; Bakota, Bore

    2015-11-01

    Ankle fractures are common injuries. Since the recognition of the importance of syndesmotic injury in ankle fractures, much of the scientific work has been focused on concomitant syndesmotic injury. Despite the invention of novel devices for restoration and maintenance of the congruent syndesmosis following syndesmotic injury, the metallic syndesmotic screw is still considered to be the "gold standard". The aim of this study was to compare the clinical results in patients who retained the syndesmosis screw with those in whom the screw was removed following open reduction and internal fixation of the malleolar fracture associated with syndesmosis disruption. This was a retrospective study of 82 patients. Minimum follow-up was 12 months. Clinical evaluation included American Orthopaedic Foot and Ankle Society (AOFAS) score and Visual Analogue Scale (VAS) for patient general satisfaction. The condition of the screw (removed, intact or broken), presence of radiolucency around the syndesmotic screw and the tibiofibular clear space were recorded using final follow-up radiographs. Three cortices were engaged in 66 patients (80%) and quadricortical fixation was performed in the remaining 16 patients (20%). The number of engaged cortices did not correlate with the clinical outcome and screw fracture. A single syndesmotic screw was used in 71 patients (86%. The mean AOFAS score in the group with intact screw (I) was 83; the scores in the group with broken screw (B) and removed screw (R) were 92.5 and 85.5, respectively. There was a statistically significant difference between the three groups: this was due to the difference between groups I and B; the difference between groups I and R and groups B and R were not statistically significant. There were no statistically significant differences in VAS results. There were no statistically significant differences in clinical outcome between the group with the screw retained and the group in which the screw was removed; however, the

  18. Morphoelastic rods. Part I: A single growing elastic rod

    KAUST Repository

    Moulton, D.E.

    2013-02-01

    A theory for the dynamics and statics of growing elastic rods is presented. First, a single growing rod is considered and the formalism of three-dimensional multiplicative decomposition of morphoelasticity is used to describe the bulk growth of Kirchhoff elastic rods. Possible constitutive laws for growth are discussed and analysed. Second, a rod constrained or glued to a rigid substrate is considered, with the mismatch between the attachment site and the growing rod inducing stress. This stress can eventually lead to instability, bifurcation, and buckling. © 2012 Elsevier Ltd. All rights reserved.

  19. Morphoelastic rods. Part I: A single growing elastic rod

    KAUST Repository

    Moulton, D.E.; Lessinnes, T.; Goriely, A.

    2013-01-01

    A theory for the dynamics and statics of growing elastic rods is presented. First, a single growing rod is considered and the formalism of three-dimensional multiplicative decomposition of morphoelasticity is used to describe the bulk growth of Kirchhoff elastic rods. Possible constitutive laws for growth are discussed and analysed. Second, a rod constrained or glued to a rigid substrate is considered, with the mismatch between the attachment site and the growing rod inducing stress. This stress can eventually lead to instability, bifurcation, and buckling. © 2012 Elsevier Ltd. All rights reserved.

  20. A study on performance of adjuster rod system and banking scheme in operational transient of CANDU-6 RUFIC core

    International Nuclear Information System (INIS)

    Kim, Soon Young; Suk, Ho Chun

    2002-01-01

    The performance of adjuster rod system in four operational transients of CANDU-6 RUFIC (Recovered Uranium Fuel In CANDU) core was preliminarily assessed, where the operational transients include startup after a short shutdown, startup after a poison-out shutdown, shim mode operation, and a stepback to 60% full power. The results of the preliminary assessment indicated that the adjuster rod system as currently designed and installed in the CANDU-6 NU (Natural Uranium) core will adequately meet the functional requirements in the RUFIC core. Comparing to the performance of adjuster rod system in the NU core, the total worth of the adjuster system in the RUFIC core is reduced, leading to less xenon override capability and shimming capability. In spite of the reduction of total worth, however, the overall performance of adjuster rod system in the operation transient of the RUFIC core is expected to still be satisfied. An alternative adjuster-banking scheme is also included in the assessment. The alternative adjuster-banking scheme involves rods in Bank 1 and Bank 7 being re-distributed within the two banks. The overall results from the transients studied indicated that the alternative banking scheme does show some better performance characteristics and merits

  1. Stability of midface fracture repair using absorbable plate and screw system pilot holes drilled and pin placement at angles other than 90°.

    Science.gov (United States)

    Carron, Michael A; Zuliani, Giancarlo; Pereira, Lucio; Abuhamdan, Maher; Thibault, Adrianna; Dau, Nathan; Bir, Cynthia

    2014-01-01

    Conventional plating systems use titanium plates for fixation of fractures, with benefits of strength and biocompatibility. However, titanium plates require that screws be placed at a 90° angle to the pilot holes. In the midface, this becomes extremely difficult. Today, a variety of craniomaxillofacial osteosynthesis systems are available, including resorbable plating systems. Specifically, the KLS Martin Sonic Weld system ultrasonically fuses the plate and the head of the pin when placed and will fill the pilot hole grooves completely even at less than 90° angles, which provides a tremendous advantage in midface fracture repair. To determine if the KLS Martin Sonic Weld system provides plate-screw construct stability in human heads even when placed at acute angles at the midface buttresses. DESIGN, SETTING, AND SPECIMENS: Twenty cadaveric head specimens with the mandible removed were prepared by creating osteotomies in the midface buttresses bilaterally. Specimens were defleshed and placed in a 2-part testing rig to hold and position the head for testing in a standard material testing system. Testing was performed at the Wayne State University Bioengineering test laboratories, Detroit, Michigan, using an Instron device and high-speed camera. Specimens were plated on one side of the midface using the KLS Martin Sonic Weld system with pilot holes and pins placed at 90° angles. On the contralateral side, the buttresses were plated with the KLS Martin Sonic Weld system at 60°, 45°, and 30° angles. Data were collected using the TDAS data acquisition system and were compared with matched pairs within each specimen. Ultrasonically vibrated pins placed into absorbable mini-plates at less than 90° angles with the KLS Martin Sonic Weld system were compared with the same amount of stress as the system placed at a 90° angle before demonstrating plate-screw construct failure. RESULTS Fifty-seven paired tests were collected, with 114 total tests. Twenty failures were

  2. Nuclear Fuel Test Rod Fabrication for Data Acquisition Test

    International Nuclear Information System (INIS)

    Joung, Chang-Young; Hong, Jin-Tae; Kim, Ka-Hye; Huh, Sung-Ho

    2014-01-01

    A nuclear fuel test rod must be fabricated with precise welding and assembly technologies, and confirmed for their soundness. Recently, we have developed various kinds of processing systems such as an orbital TIG welding system, a fiber laser welding system, an automated drilling system and a helium leak analyzer, which are able to fabricate the nuclear fuel test rods and rigs, and keep inspection systems to confirm the soundness of the nuclear fuel test rods and rids. The orbital TIG welding system can be used with two kinds of welding methods. One can perform the round welding for end-caps of a nuclear fuel test rod by an orbital head mounted in a low-pressure chamber. The other can do spot welding for a pin-hole of a nuclear fuel test rod in a high-pressure chamber to fill up helium gas of high pressure. The fiber laser welding system can weld cylindrical and 3 axis samples such as parts of a nuclear fuel test rod and instrumentation sensors which is moved by an index chuck and a 3 axis (X, Y, Z) servo stage controlled by the CNC program. To measure the real-time temperature change at the center of the nuclear fuel during the irradiation test, a thermocouple should be instrumented at that position. Therefore, a hole needs to be made at the center of fuel pellet to instrument the thermocouple. An automated drilling system can drill a fine hole into a fuel pellet without changing tools or breaking the work-piece. The helium leak analyzer (ASM-380 model of DEIXEN Co.) can check the leak of the nuclear fuel test rod filled with helium gas. This paper describes not only the assembly and fabrication methods used by the process systems, but also the results of the data acquisition test for the nuclear fuel test rod. A nuclear fuel test rod for the data acquisition test was fabricated using the welding and assembling echnologies acquired from previous tests

  3. Nuclear Fuel Test Rod Fabrication for Data Acquisition Test

    Energy Technology Data Exchange (ETDEWEB)

    Joung, Chang-Young; Hong, Jin-Tae; Kim, Ka-Hye; Huh, Sung-Ho [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of)

    2014-10-15

    A nuclear fuel test rod must be fabricated with precise welding and assembly technologies, and confirmed for their soundness. Recently, we have developed various kinds of processing systems such as an orbital TIG welding system, a fiber laser welding system, an automated drilling system and a helium leak analyzer, which are able to fabricate the nuclear fuel test rods and rigs, and keep inspection systems to confirm the soundness of the nuclear fuel test rods and rids. The orbital TIG welding system can be used with two kinds of welding methods. One can perform the round welding for end-caps of a nuclear fuel test rod by an orbital head mounted in a low-pressure chamber. The other can do spot welding for a pin-hole of a nuclear fuel test rod in a high-pressure chamber to fill up helium gas of high pressure. The fiber laser welding system can weld cylindrical and 3 axis samples such as parts of a nuclear fuel test rod and instrumentation sensors which is moved by an index chuck and a 3 axis (X, Y, Z) servo stage controlled by the CNC program. To measure the real-time temperature change at the center of the nuclear fuel during the irradiation test, a thermocouple should be instrumented at that position. Therefore, a hole needs to be made at the center of fuel pellet to instrument the thermocouple. An automated drilling system can drill a fine hole into a fuel pellet without changing tools or breaking the work-piece. The helium leak analyzer (ASM-380 model of DEIXEN Co.) can check the leak of the nuclear fuel test rod filled with helium gas. This paper describes not only the assembly and fabrication methods used by the process systems, but also the results of the data acquisition test for the nuclear fuel test rod. A nuclear fuel test rod for the data acquisition test was fabricated using the welding and assembling echnologies acquired from previous tests.

  4. Control rod drive

    International Nuclear Information System (INIS)

    Hawke, B.C.

    1986-01-01

    A reactor core, one or more control rods, and a control rod drive are described for selectively inserting and withdrawing the one or more control rods into and from the reactor core, which consists of: a support structure secured beneath the reactor core; control rod positioning means supported by the support structure for movably supporting the control rod for movement between a lower position wherein the control rod is located substantially beneath the reactor core and an upper position wherein at least an upper portion of the control rod extends into the reactor core; transmission means; primary drive means connected with the control rod positioning means by the transmission means for positioning the control rod under normal operating conditions; emergency drive means for moving the control rod from the lower position to the upper position under emergency conditions, the emergency drive means including a weight movable between an upper and a lower position, means for movably supporting the weight, and means for transmitting gravitational force exerted on the weight to the control rod positioning means to move the control rod upwardly when the weight is pulled downwardly by gravity; the transmission means connecting the control rod positioning means with the emergency drive means so that the primary drive means effects movement of the weight and the control rod in opposite directions under normal conditions, thus providing counterbalancing to reduce the force required for upward movement of the control rod under normal conditions; and restraint means for restraining the fall of the weight under normal operating conditions and disengaging the primary drive means to release the weight under emergency conditions

  5. Analysis of Modeling Parameters on Threaded Screws.

    Energy Technology Data Exchange (ETDEWEB)

    Vigil, Miquela S. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Brake, Matthew Robert [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Vangoethem, Douglas [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States)

    2015-06-01

    Assembled mechanical systems often contain a large number of bolted connections. These bolted connections (joints) are integral aspects of the load path for structural dynamics, and, consequently, are paramount for calculating a structure's stiffness and energy dissipation prop- erties. However, analysts have not found the optimal method to model appropriately these bolted joints. The complexity of the screw geometry cause issues when generating a mesh of the model. This paper will explore different approaches to model a screw-substrate connec- tion. Model parameters such as mesh continuity, node alignment, wedge angles, and thread to body element size ratios are examined. The results of this study will give analysts a better understanding of the influences of these parameters and will aide in finding the optimal method to model bolted connections.

  6. An Examination Of Fracture Splitting Parameters Of Crackable Connecting Rods

    Directory of Open Access Journals (Sweden)

    Zafer Özdemir

    2000-06-01

    Full Text Available Fracture splitting method is an innovative processing technique in the field of automobile engine connecting rod (con/rod manufacturing. Compared with traditional method, this technique has remarkable advantages. Manufacturing procedures, equipment and tools investment can be decreased and energy consumption reduced remarkably. Furthermore, product quality and bearing capability can also be improved. It provides a high quality, high accuracy and low cost route for producing connecting rods (con/rods. With the many advantages mentioned above, this method has attracted manufacturers attention and has been utilized in many types of con/rod manufacturing. In this article, the method and the advantages it provides, such as materials, notches for fracture splitting, fracture splitting conditions and fracture splitting equipment are discussed in detail. The paper describes an analysis of examination of fracture splitting parameters and optik-SEM fractography of C70S6 crackable connectıng rod. Force and velocity parameters are investigated. That uniform impact force distrubition starting from the starting notch causes brittle and cleavage failure mode is obtained as a result. This induces to decrease the toughness.

  7. First Metatarsophalangeal Joint Arthrodesis: A Retrospective Comparison of Crossed-screws, Locking and Non-Locking Plate Fixation with Lag Screw

    Directory of Open Access Journals (Sweden)

    Leif Claassen

    2017-07-01

    Full Text Available Background:Locking plate fixation is increasingly used for first metatarsophalangeal joint (MTP-I arthrodesis. Still there is few comparable clinical data regarding this procedure. Methods:We retrospectively evaluated 60 patients who received an arthrodesis of the MTP-I between January 2008 and June 2010. With 20 patients each we performed a locking plate fixation with lag screw, arthrodesis with crossed-screwsor with a nonlocking plate with lag screw. Results: There were four non-unions in crossed-screws patients and one nonunion in non-locked plate group. All the patients in locking plate group achieved union. 90% of the patients were completely or mildly satisfied in locking plate group, whereas this rate was 80% for patients in both crossed screws and non-locking plate groups. Conclusions: Use of dorsal plating for arthrodesis of MTP1 joint either locking or non-locking were associated with high union rate and acceptable and comparable functional outcome. Although nonunion rate was high using two crossed screws but functional outcome was not significantly different compare to dorsal plating. Level of evidence:Ш, retrospective comparative study

  8. d = 2 transverse-field Ising model under the screw-boundary condition: an optimization of the screw pitch

    International Nuclear Information System (INIS)

    Nishiyama, Yoshihiro

    2011-01-01

    A length-N spin chain with the √N(=v)th neighbor interaction is identical to a two-dimensional (d = 2) model under the screw-boundary (SB) condition. The SB condition provides a flexible scheme to construct a d ≥ 2 cluster from an arbitrary number of spins; the numerical diagonalization combined with the SB condition admits a potential applicability to a class of systems intractable with the quantum Monte Carlo method due to the negative-sign problem. However, the simulation results suffer from characteristic finite-size corrections inherent in SB. In order to suppress these corrections, we adjust the screw pitch v(N) so as to minimize the excitation gap for each N. This idea is adapted to the transverse-field Ising model on the triangular lattice with N ≤ 32 spins. As a demonstration, the correlation-length critical exponent ν is analyzed in some detail

  9. A new corrective technique for adolescent idiopathic scoliosis (Ucar′s convex rod rotation

    Directory of Open Access Journals (Sweden)

    Bekir Yavuz Ucar

    2014-01-01

    Full Text Available Study Design: Prospective single-center study. Objective: To analyze the efficacy and safety of a new technique of global vertebral correction with convex rod rotation performed on the patients with adolescent idiopathic scoliosis. Summary of Background Data: Surgical goal is to obtain an optimal curve correction in scoliosis surgery. There are various correction techniques. This report describes a new technique of global vertebral correction with convex rod rotation. Materials and Methods: A total of 12 consecutive patients with Lenke type I adolescent idiopathic scoliosis and managed by convex rod rotation technique between years 2012 and 2013 having more than 1 year follow-up were included. Mean age was 14.5 (range = 13-17 years years at the time of operation. The hospital charts were reviewed for demographic data. Measurements of curve magnitude and balance were made on 36-inch standing anteroposterior and lateral radiographs taken before surgery and at most recent follow up to assess deformity correction, spinal balance, and complications related to the instrumentation. Results: Preoperative coronal plane major curve of 62° (range = 50°-72° with flexibility of less than 30% was corrected to 11.5°(range = 10°-14° showing a 81% scoliosis correction at the final follow-up. Coronal imbalance was improved 72% at the most recent follow-up assessment. No complications were found. Conclusion: The new technique of global vertebral correction with Ucar′s convex rod rotation is an effective technique. This method is a vertebral rotation procedure from convex side and it allows to put screws easily to the concave side.

  10. Dry Rod Consolidation Technology Project results

    International Nuclear Information System (INIS)

    Mullen, C.K.; Feldman, E.M; Vinjamuri, K.; Griebenow, B.L.; Lynch, R.J.; Arave, A.E.; Hill, R.C.

    1988-01-01

    The Dry Rod Consolidation Technology (DRCT) Project conducted at the Idaho National Engineering Laboratory (INEL), in 1987 demonstrated the technical feasibility of a dry horizontal fuel rod consolidation process. Fuel rods from Westinghouse 15 /times/ 15 pressurized water reactor (PWR) spent fuel assemblies were consolidated into canisters to achieve a 2:1 volume reduction ratio. The consolidation equipment was operated at an existing hot cell complex at the INEL. The equipment was specifically designed to interface with the existing facility fuel handling and operational capabilities and was instrumented to provide data collection for process technology research. During the operational phase, data were collected from observation of the consolidation process, fuel assembly handling, and fuel rod behavior and characteristics. Equipment performance was recorded and data measurements were compiled on crud and contamination generated and spread. Fuel assembly skeletons [non-fuel bearing components (NFBC)] were gamma scanned and analyzed for isotopic content and profile. The above data collection was enhanced by extensive photograph and video documentation. The loaded consolidation fuel canisters were utilized for a test of the Transnuclear, Inc. TN-24P dry storage cask with consolidated fuel. The NFBC material was stored for a future volume reduction demonstration project. 14 figs., 4 tabs

  11. Absorber rod drive for nuclear reactors

    International Nuclear Information System (INIS)

    Acher, H.

    1985-01-01

    The invention concerns a further addition to the invention of DE 33 42 830 A1. The free contact of the hollow piston with the nut due to hydraulic pressure is replaced by a hydraulic or spring attachment. The pressure system required to produce the hydraulic pressure is therefore omitted, and the electrical power required for driving the pump or the mass flow is also omitted. The absorber rod slotted along its longitudinal axis is replaced by an absorber rod, in the longitudinal axis of which a hollow piston is connected together with the absorber rod. This makes the absorber rod more stable, and assembly is simplified. (orig./HP) [de

  12. Multilevel Direct Repair Surgery for Three-Level Lumbar Spondylolysis

    Directory of Open Access Journals (Sweden)

    Tetsu Arai

    2013-01-01

    Full Text Available A 45-year-old man presented to our clinic requesting evaluation for surgical treatment of chronic low back pain of more than 20 years duration. He was diagnosed with 3-level lumbar spondylolysis at L3–5. Direct repair using the pedicle screw and hook-rod system was conducted for all three levels. After the surgery, his low back pain completely disappeared. Six months later, he felt discomfort and heard a metallic sound as he twisted his trunk. Computed tomography and radiography indicated that the hook head for L3 and the screw head for L4 were interfering with each other, causing the sound. We confirmed bony union at L3 and removed the L3 system. Surgeons should be aware of such complications if direct repair using a pedicle screw and hook-rod system is conducted for multilevel spondylolysis.

  13. Robot assisted navigated drilling for percutaneous pedicle screw placement: A preliminary animal study

    Directory of Open Access Journals (Sweden)

    Hongwei Wang

    2015-01-01

    Conclusions: The preliminary study supports the view that computer assisted pedicle screw fixation using spinal robot is feasible and the robot can decrease the intraoperative fluoroscopy time during the minimally invasive pedicle screw fixation surgery. As spine robotic surgery is still in its infancy, further research in this field is worthwhile especially the accuracy of spine robot system should be improved.

  14. Use of a continuous twin screw granulation and drying system during formulation development and process optimization.

    Science.gov (United States)

    Vercruysse, J; Peeters, E; Fonteyne, M; Cappuyns, P; Delaet, U; Van Assche, I; De Beer, T; Remon, J P; Vervaet, C

    2015-01-01

    Since small scale is key for successful introduction of continuous techniques in the pharmaceutical industry to allow its use during formulation development and process optimization, it is essential to determine whether the product quality is similar when small quantities of materials are processed compared to the continuous processing of larger quantities. Therefore, the aim of this study was to investigate whether material processed in a single cell of the six-segmented fluid bed dryer of the ConsiGma™-25 system (a continuous twin screw granulation and drying system introduced by GEA Pharma Systems, Collette™, Wommelgem, Belgium) is predictive of granule and tablet quality during full-scale manufacturing when all drying cells are filled. Furthermore, the performance of the ConsiGma™-1 system (a mobile laboratory unit) was evaluated and compared to the ConsiGma™-25 system. A premix of two active ingredients, powdered cellulose, maize starch, pregelatinized starch and sodium starch glycolate was granulated with distilled water. After drying and milling (1000 μm, 800 rpm), granules were blended with magnesium stearate and compressed using a Modul™ P tablet press (tablet weight: 430 mg, main compression force: 12 kN). Single cell experiments using the ConsiGma™-25 system and ConsiGma™-1 system were performed in triplicate. Additionally, a 1h continuous run using the ConsiGma™-25 system was executed. Process outcomes (torque, barrel wall temperature, product temperature during drying) and granule (residual moisture content, particle size distribution, bulk and tapped density, hausner ratio, friability) as well as tablet (hardness, friability, disintegration time and dissolution) quality attributes were evaluated. By performing a 1h continuous run, it was detected that a stabilization period was needed for torque and barrel wall temperature due to initial layering of the screws and the screw chamber walls with material. Consequently, slightly deviating

  15. Three-Rod Resonator for Krypton Lamp Pumped 1.8 kW Continuous-Wave Nd:YAG Laser

    Institute of Scientific and Technical Information of China (English)

    LI Qiang; FANG Ming-Xing; WANG Zhi-Yong; YU Zhen-Sheng; LEI Hong; GUO Jiang; LI Gang; ZUO Tie-Chuan

    2004-01-01

    @@ A three-rod series resonator cw Nd:YAG laser suitable for the industrial applications is presented. The symmetrical resonator laser has been developed and is rated at 1820-W output power with beam parameter product 24 mm.mrad. By utilizing the symmetrical resonator design, the characteristic of beam with multi-rod is not obviously decreased compared with that of a single one. The system total electro-optics efficiency of lamp pumped YAG crystal is as high as 4.0%. The main factors, which affect output power and beam quality of high power solid-state laser module, are theoretically analysed.

  16. The accuracy and safety of fluoroscopically guided percutaneous pedicle screws in the lumbosacral junction and the lumbar spine: a review of 880 screws.

    Science.gov (United States)

    Chiu, C K; Kwan, M K; Chan, C Y W; Schaefer, C; Hansen-Algenstaedt, N

    2015-08-01

    We undertook a retrospective study investigating the accuracy and safety of percutaneous pedicle screws placed under fluoroscopic guidance in the lumbosacral junction and lumbar spine. The CT scans of patients were chosen from two centres: European patients from University Medical Center Hamburg-Eppendorf, Germany, and Asian patients from the University of Malaya, Malaysia. Screw perforations were classified into grades 0, 1, 2 and 3. A total of 880 percutaneous pedicle screws from 203 patients were analysed: 614 screws from 144 European patients and 266 screws from 59 Asian patients. The mean age of the patients was 58.8 years (16 to 91) and there were 103 men and 100 women. The total rate of perforation was 9.9% (87 screws) with 7.4% grade 1, 2.0% grade 2 and 0.5% grade 3 perforations. The rate of perforation in Europeans was 10.4% and in Asians was 8.6%, with no significant difference between the two (p = 0.42). The rate of perforation was the highest in S1 (19.4%) followed by L5 (14.9%). The accuracy and safety of percutaneous pedicle screw placement are comparable to those cited in the literature for the open method of pedicle screw placement. Greater caution must be taken during the insertion of L5 and S1 percutaneous pedicle screws owing to their more angulated pedicles, the anatomical variations in their vertebral bodies and the morphology of the spinal canal at this location. ©2015 The British Editorial Society of Bone & Joint Surgery.

  17. Passage of an Anterior Odontoid Screw through Gastrointestinal Tract.

    Science.gov (United States)

    Leitner, L; Brückmann, C I; Gilg, M M; Bratschitsch, G; Sadoghi, P; Leithner, A; Radl, R

    2017-01-01

    Purpose . Anterior screw fixation has become a popular surgical treatment method for instable odontoid fractures. Screw loosening and migration are a rare, severe complication following anterior odontoid fixation, which can lead to esophagus perforation and requires revision operation. Methods . We report a case of screw loosening and migration after anterior odontoid fixation, which perforated the esophagus and was excreted without complications in a 78-year-old male patient. Results . A ventral dislocated anterior screw perforated through the esophagus after eight years after implantation and was excreted through the gastrointestinal (GI) tract. At a 6-month follow-up after the event the patient was asymptomatic. Conclusion . Extrusion via the GI tract is not safe enough to be considered as a treatment option for loosened screws. Some improvements could be implemented to prevent such an incident. Furthermore, this case is a fine example that recent preoperative imaging is mandatory before revision surgery for screw loosening.

  18. Passage of an Anterior Odontoid Screw through Gastrointestinal Tract

    Directory of Open Access Journals (Sweden)

    L. Leitner

    2017-01-01

    Full Text Available Purpose. Anterior screw fixation has become a popular surgical treatment method for instable odontoid fractures. Screw loosening and migration are a rare, severe complication following anterior odontoid fixation, which can lead to esophagus perforation and requires revision operation. Methods. We report a case of screw loosening and migration after anterior odontoid fixation, which perforated the esophagus and was excreted without complications in a 78-year-old male patient. Results. A ventral dislocated anterior screw perforated through the esophagus after eight years after implantation and was excreted through the gastrointestinal (GI tract. At a 6-month follow-up after the event the patient was asymptomatic. Conclusion. Extrusion via the GI tract is not safe enough to be considered as a treatment option for loosened screws. Some improvements could be implemented to prevent such an incident. Furthermore, this case is a fine example that recent preoperative imaging is mandatory before revision surgery for screw loosening.

  19. Electromagnetic device of the safety screw-nut type

    International Nuclear Information System (INIS)

    Defaucheux, Jean; Guedj, Freddy.

    1981-01-01

    System providing for the vertical displacement of nuclear reactor control rods in a non-magnetic and cylindrical leak tight containment. This device is composed of a stator located around the upper part of the containment and, inside this containment, a rotor also in the upper part of this containment, which is free in axial translation along its shaft which it drives rotationally but which is fixed in translation. This shaft drives a threaded rod working in conjunction with a nut and able to slide vertically without turning inside the containment and supporting the reactor control rods. When the stator is not powered, the threaded rod and nut assembly falls to the bottom of the containment and may be easily raised by powering the stator [fr

  20. Acoustic loading effects on oscillating rod bundles

    International Nuclear Information System (INIS)

    Lin, W.H.

    1980-01-01

    An analytical study of the interaction between an infinite acoustic medium and a cluster of circular rods is described. The acoustic field due to oscillating rods and the acoustic loading on the rods are first solved in a closed form. The acoustic loading is then used as a forcing function for rod responses, and the acousto-elastic couplings are solved simultaneously. Numerical examples are presented for several cases to illustrate the effects of various system parameters on the acoustic reaction force coefficients. The effect of the acoustic loading on the coupled eigenfrequencies are discussed

  1. Experimental study of pedicle screw stability on low BMD vertebrae

    International Nuclear Information System (INIS)

    Li Qi; Yang Huilin; Tang Tiansi; Wu Yiwei; Wang Yijin

    2005-01-01

    Objective: To conduct biomechanical study of different pedicle screws stability on spinal specimen, discuss the relationship between design parameter of screw, insertion torgue and BMD, establish the theoretical foundation for application of pedicle screw on osteoporotic patients. Methods: Six fixed lumbar cadavers were collected, the effects of design parameter, insertion torque and etc on fixation stability were determined under various BMD by using biomechanical ways. Results: According to in vitro study: (1) There was a significant difference among pullout strength of all screws (P 2 >U 1 >SF 1 >SF 2 >RF. Conclusions: There is a close correlated between type of screw, BMD and stability. The U-type screw displays the best fixation effect on specimen of low BMD. (authors)

  2. NAPP liquid shutoff rod system design, development, testing and precommissioning feed back study

    International Nuclear Information System (INIS)

    Soni, K.L.; Kaushik, R.V.; Mahajan, S.V.

    1989-01-01

    The development testing of a liquid poison shutoff rod system has enabled the evolution of a proven and acceptable design of the secondary shutdown system for 235 MWe standardised Pressurised Heavy Water Reactors (PHWRs). The availability of a full scale test loop is also proving for checking and qualifying the various suggestions for online improvements in the system. (author)

  3. Safety and surgical techniques of C1 lateral mass screws

    International Nuclear Information System (INIS)

    Kubo, Shinichiro; Kuroki, Hiroshi; Hanado, Shoji; Hamanaka, Hideaki; Inomata, Naoki; Kuroki, Shuji; Chosa, Etsuo

    2010-01-01

    The objectives of this study were to evaluate the proper insertion techniques of C1 lateral mass screws. Eighteen consecutive patients were examined after upper cervical fusion using twenty-nine C1 lateral mass screws. Screws were placed by three different techniques; Goel's technique (4), Tan's technique (20), Notching technique (5). Pre and post-operative CT scans with multiplanar reconstruction were used to detect cortical breaches and direction of screws. No transverse foramen and vertebral groove violation was found in CT scans. Three had breached superior articular facet of the atlas. However, the range of motion (R.O.M) of atlanto-occipital joints had not changed postoperatively. Theses screws were inserted with Tan's technique and two of three were directed medially. It is feasible to safely insert C1 lateral mass screws when correct insertion point and direction are considered preoperatively. However, care should be taken because screws can violate the atlanto-occipital joint especially with Tan's technique. (author)

  4. Accuracy of pedicle screw placement in patients with Marfan syndrome.

    Science.gov (United States)

    Qiao, Jun; Zhu, Feng; Xu, Leilei; Liu, Zhen; Sun, Xu; Qian, Bangping; Jiang, Qing; Zhu, Zezhang; Qiu, Yong

    2017-03-21

    There is no study concerning safety and accuracy of pedicle screw placement in Marfan syndrome. The objective of this study is to investigate accuracy and safety of pedicle screw placement in scoliosis associated with Marfan syndrome. CT scanning was performed to analyze accuracy of pedicle screw placement. Pedicle perforations were classified as medial, lateral or anterior and categorized to four grades: ≤ 2 mm as Grade 1, 2.1-4.0 mm as Grade 2, 4.1-6.0 mm as Grade 3, ≥6.1 mm as Grade 4. Fully contained screws or with medial wall perforation ≤ 2 mm or with lateral wall perforation ≤ 6 mm and without injury of visceral organs were considered acceptable, otherwise were unacceptable. 976 pedicle screws were placed, 713 screws (73.1%) were fully contained within the cortical boundaries of the pedicle. 924 (94.7%) screws were considered as acceptable, and 52 (5.3%) as unacceptable. The perforation rate was higher using free-hand technique than O-arm navigation technique (30.8% VS. 11.4%, P Marfan syndrome is accuracy and safe. O-arm navigation was an effective modality to ensure the safety and accuracy of screw placement. Special attention should be paid when screws were placed at the lumber spine and the concave side of spine deformity to avoid the higher rate of complications.

  5. Influence Of Specific Mechanical Energy On Cornmeal Viscosity Measured By An On-line System During Twin-screw Extrusion

    OpenAIRE

    Chang Y.K.; Martinez-Bustos F.; Park T.S.; Kokini J.L.

    1999-01-01

    The influence of specific mechanical energy (SME) on cornmeal viscosity during the twin-screw extrusion at feed moisture contents of 25 and 30% and screw speeds in the range from 100 to 500 rpm was measured. Cornmeal was extruded in a co-rotating, intermeshing twin-screw coupled to a slit die rheometer. One approach to the on-line rheological measurement is to use a slit die with the extruder. In the present work it was show that shear viscosity decreased as a function of SME. The viscosity o...

  6. Process and remote device for unscrewing and extracting an assembly screw

    International Nuclear Information System (INIS)

    Lagarrigue, F.

    1990-01-01

    The device comprises a C-shaped frame, with two parallel arms and a joining section fixed at one end of a long support, an extraction screw engaged in a hole through one arm and having one end made of a centre punch directed towards the inside of the frame and a remote mean for screwed or unscrewed the extraction screw. A supporting and centering piece can also be fixed to the second branch of the frame. The screw is extracted by exerting a moment about the axis of the screw through the support and frame after tightening the extraction screw. This device can be used particularly for the unscrewing and the extraction of the screw of the springs of a nuclear fuel assembly [fr

  7. Design requirement on KALIMER control rod assembly duct

    International Nuclear Information System (INIS)

    Hwang, W.; Kang, H. Y.; Nam, C.; Kim, J. O.; Kim, Y. J.

    1998-03-01

    This document establishes the design guidelines which are needs for designing the control rod assembly duct of the KALIMER as design requirements. it describes control rod assembly duct of the KALIMER and its requirements that includes functional requirements, performance requirements, interfacing systems, design limits and strength requirements, seismic requirements, structural requirements, environmental requirements, reliability and safety requirements, standard and codes, QA programs, and other requirements. The control rod system consists of three parts, which are drive mechanism, drive-line, and absorber bundle. This report deals with the absorber bundle and its outer duct only because the others are beyond the scope of fuel system design. The guidelines for design requirements intend to be used for an improved design of the control rod assembly duct of the KALIMER. (author). 19 refs

  8. Design requirement on KALIMER control rod assembly duct

    Energy Technology Data Exchange (ETDEWEB)

    Hwang, W.; Kang, H. Y.; Nam, C.; Kim, J. O.; Kim, Y. J

    1998-03-01

    This document establishes the design guidelines which are needs for designing the control rod assembly duct of the KALIMER as design requirements. it describes control rod assembly duct of the KALIMER and its requirements that includes functional requirements, performance requirements, interfacing systems, design limits and strength requirements, seismic requirements, structural requirements, environmental requirements, reliability and safety requirements, standard and codes, QA programs, and other requirements. The control rod system consists of three parts, which are drive mechanism, drive-line, and absorber bundle. This report deals with the absorber bundle and its outer duct only because the others are beyond the scope of fuel system design. The guidelines for design requirements intend to be used for an improved design of the control rod assembly duct of the KALIMER. (author). 19 refs.

  9. Optimization of a rod pinch diode radiography source at 2.3 MV

    International Nuclear Information System (INIS)

    Menge, P.R.; Johnson, D.L.; Maenchen, J.E.; Rovang, D.C.; Oliver, B.V.; Rose, D.V.; Welch, D.R.

    2003-01-01

    Rod pinch diodes have shown considerable capability as high-brightness flash x-ray sources for penetrating dynamic radiography. The rod pinch diode uses a small diameter (0.4-2 mm) anode rod extended through a cathode aperture. When properly configured, the electron beam born off of the aperture edge can self-insulate and pinch onto the tip of the rod creating an intense, small x-ray source. Sandia's SABRE accelerator (2.3 MV, 40 Ω, 70 ns) has been utilized to optimize the source experimentally by maximizing the figure of merit (dose/spot diameter2) and minimizing the diode impedance droop. Many diode parameters have been examined including rod diameter, rod length, rod material, cathode aperture diameter, cathode thickness, power flow gap, vacuum quality, and severity of rod-cathode misalignment. The configuration producing the greatest figure of merit uses a 0.5 mm diameter gold rod, a 6 mm rod extension beyond the cathode aperture (diameter=8 mm), and a 10 cm power flow gap to produce up to 3.5 rad (filtered dose) at 1 m from a 0.85 mm x-ray on-axis spot (1.02 mm at 3 deg. off axis). The resultant survey of parameter space has elucidated several physics issues that are discussed

  10. French LMFBR's control rods experience and development

    International Nuclear Information System (INIS)

    Arnaud, G.; Guigon, A.; Verset, L.

    1983-06-01

    Since the last ten years, the French program has been, first of all, directed to the setting up, and then the development of, at once, the Phenix control rods, and next, the Super-Phenix ones. The vented pin design, with porous plug and sodium bonding, which allows the choices of large diameters, has been taken, since the Rapsodie experience was decisive. The absorber material is sintered, 10 B enriched, boron carbide. The can is made of 316 type stainless steel, stabilised, or not, with titanium. The experience gained in Phenix up to now is important, and deals with about six loads of control rods. Results confirm the validity of the design of the absorber pins. Some difficulties has been encountered for the guiding devices, due to the swelling of the steel. They have required design and material improvements. Such difficulties are discarded by a new design of the bearing, for the Super-Phenix control rods. The other parts of these rods, from the Primary Shut-Down System, are strictly derived from Phenix. The design of the rods from the Secondary Shut-Down System is rather different, but it's not the case for the design of the absorber pins: in many a way, they are derived from Phenix pins and from Rapsodie control rods. Both types of rods irradiation tests are in progress in Phenix [fr

  11. Technical Development of Gamma Scanning for Irradiated Fuel Rod after Upgrade of System in Hot-cell

    Energy Technology Data Exchange (ETDEWEB)

    Ryu, Woo Seog; Kim, Hee Moon; Baik, Seung Je; Yoo, Byung Ok; Choo, Yong Sun

    2007-06-15

    Non-destructive test system was installed at hot-cell(M1) in IMEF(Irradiated Materials Examination Facility) more than 10 years ago for the diametric measurement and gamma scanning of fuel rod. But this system must be needed to be remodeled for the effective operations. In 2006, the system was upgraded for 3 months. The collimator bench can be movable with horizontal direction(x-direction) by motorized system for sectional gamma scanning and 3-dimensional tomography of fuel rod. So, gamma scanning for fuel rod can be detectable by x, y and rotation directions. It may be possible to obtain the radioactivities with radial and axial directions of pellet. This system is good for the series experiments with several positions. Operation of fuel bench and gamma detection program were linked each other by new program tools. It can control detection and bench moving automatically when gamma inspection of fuel rod is carried out with axial or radial positions. Some of electronic parts were added in PLC panel, and operating panel was re-designed for the remote control. To operate the fuel bench by computer, AD converter and some I/O cards were installed in computer. All of software were developed in Windows-XP system instead of DOS system. Control programs were made by visual-C language. After upgrade of system, DUPIC fuel which was irradiated in HANARO research reactor was detected by gamma scanning. The results were good and operation of gamma scanning showed reduced inspection time and easy control of data on series of detection with axial positions. With consideration of ECT(Eddy Current Test) installation, the computer program and hardware were set up as well. But ECT is not installed yet, so we have to check abnormal situation of program and hardware system. It is planned to install ECT in 2007.

  12. In Vivo Evaluation of Immediately Loaded Stainless Steel and Titanium Orthodontic Screws in a Growing Bone

    OpenAIRE

    Gritsch, Kerstin; Laroche, Norbert; Bonnet, Jeanne-Marie; Exbrayat, Patrick; Morgon, Laurent; Rabilloud, Muriel; Grosgogeat, Brigitte

    2013-01-01

    The present work intends to evaluate the use of immediate loaded orthodontic screws in a growing model, and to study the specific bone response. Thirty-two screws (half of stainless steel and half of titanium) were inserted in the alveolar bone of 8 growing pigs. The devices were immediately loaded with a 100 g orthodontic force. Two loading periods were assessed: 4 and 12 weeks. Both systems of screws were clinically assessed. Histological observations and histomorphometric analysis evaluate...

  13. BIOMECHANICAL EVALUATION OF THE INFLUENCE OF CERVICAL SCREWS TAPPING AND DESIGN.

    Science.gov (United States)

    Silva, Patricia; Rosa, Rodrigo César; Shimano, Antonio Carlos; Albuquerque de Paula, Francisco José; Volpon, José Batista; Aparecido Defino, Helton Luiz

    2009-01-01

    To assess if the screw design (self-drilling/self-tapping) and the pilot hole tapping could affect the insertion torque and screw pullout strength of the screw used in anterior fixation of the cervical spine. Forty self-tapping screws and 20 self-drilling screws were inserted into 10 models of artificial bone and 10 cervical vertebrae of sheep. The studied parameters were the insertion torque and pullout strength. The following groups were created: Group I-self-tapping screw insertion after pilot hole drilling and tapping; Group II-self-tapping screw insertion after pilot hole drilling without tapping; Group III-self-drilling screw insertion without drilling and tapping. In Groups I and II, the pilot hole had 14.0 mm in depth and was made with a 3mmn drill, while tapping was made with a 4mm tap. The insertion torque was measured and the pullout test was performed. The comparison between groups was made considering the mean insertion torque and the maximum mean pullout strength with the variance analysis (ANOVA; p≤ 0.05). Previous drilling and tapping of pilot hole significantly decreased the insertion torque and the pullout strength. The insertion torque and pullout strength of self-drilling screws were significantly higher when compared to self-tapping screws inserted after pilot hole tapping.

  14. Replacement rod

    International Nuclear Information System (INIS)

    Hatfield, S.C.

    1989-01-01

    This patent describes in an elongated replacement rod for use with fuel assemblies of the type having two end fittings connected by guide tubes with a plurality of rod and guide tube cell defining spacer grids containing rod support features and mixing vanes. The grids secured to the guide tubes in register between the end fittings at spaced intervals. The fuel rod comprising: an asymmetrically beveled tip; a shank portion having a straight centerline; and a permanently diverging portion between the tip and the shank portion

  15. Spider and burnable poison rod combinations

    International Nuclear Information System (INIS)

    Walton, L.A.

    1980-01-01

    A description is given of an improved design of burnable poison rods and their associated spiders used in the fuel assemblies of pressurized water power reactor cores which allows the rods to be installed and removed more quickly, simply and gently than in previously described systems. (U.K.)

  16. Posterior cervical spine arthrodesis with laminar screws. A report of two cases

    International Nuclear Information System (INIS)

    Nakanishi, Kazuo; Tanaka, Masato; Sugimoto, Yoshihisa; Ozaki, Toshifumi

    2007-01-01

    We performed fixation using laminar screws in 2 patients in whom lateral mass screws, pedicle screws or transarticular screws could not be inserted. One was a 56-year-old woman who had anterior atlantoaxial subluxation (AAS). When a guide wire was inserted using an imaging guide, the hole bled massively. We thought the re-insertion of a guide wire or screw would thus increase the risk of vascular injury, so we used laminar screws. The other case was an 18-year-old man who had a hangman fracture. Preoperative magnetic resonance angiography showed occlusion of the left vertebral artery. A laminar screw was inserted into the patent side (i.e., the right side of C2). Cervical pedicle screws are the most biomechanically stable screws. However, their use carries a high risk of neurovascular complications during screw insertion, because the cervical pedicle is small and is adjacent laterally to the vertebral artery, medially to the spinal cord, and vertically to the nerve roots. Lateral mass screws are also reported to involve a risk of neurovascular injuries. The laminar screw method was thus thought to be useful, since arterial injuries could thus be avoided and it could also be used as a salvage modality for the previous misinsertion. (author)

  17. Non-symmetric approach to single-screw expander and compressor modeling

    Science.gov (United States)

    Ziviani, Davide; Groll, Eckhard A.; Braun, James E.; Horton, W. Travis; De Paepe, M.; van den Broek, M.

    2017-08-01

    Single-screw type volumetric machines are employed both as compressors in refrigeration systems and, more recently, as expanders in organic Rankine cycle (ORC) applications. The single-screw machine is characterized by having a central grooved rotor and two mating toothed starwheels that isolate the working chambers. One of the main features of such machine is related to the simultaneous occurrence of the compression or expansion processes on both sides of the main rotor which results in a more balanced loading on the main shaft bearings with respect to twin-screw machines. However, the meshing between starwheels and main rotor is a critical aspect as it heavily affects the volumetric performance of the machine. To allow flow interactions between the two sides of the rotor, a non-symmetric modelling approach has been established to obtain a more comprehensive model of the single-screw machine. The resulting mechanistic model includes in-chamber governing equations, leakage flow models, heat transfer mechanisms, viscous and mechanical losses. Forces and moments balances are used to estimate the loads on the main shaft bearings as well as on the starwheel bearings. An 11 kWe single-screw expander (SSE) adapted from an air compressor operating with R245fa as working fluid is used to validate the model. A total of 60 steady-steady points at four different rotational speeds have been collected to characterize the performance of the machine. The maximum electrical power output and overall isentropic efficiency measured were 7.31 kW and 51.91%, respectively.

  18. Common Cause Failure Analysis of Control Rods and Drives in the Swedish and Finnish BWR Plants. Operating Experiences in 1983 - 2003

    Energy Technology Data Exchange (ETDEWEB)

    Mankamo, Tuomas [Avaplan Oy, Espoo (Finland)

    2006-11-15

    The control rod and drives in a Boiling Water Reactor (BWR) constitute a highly redundant system. The reliability of the system is determined by how well the design withstands dependencies, as Common Cause Failures (CCFs). This report upgrades an earlier data collection on CCFs of control rod and drives (SKI Report 1996:77) to more recent years, with the objective to report the data to ICDE project (International Common Cause Failure Data Exchange) and to the safety analysts in the Nordic countries. The operating experiences were analyzed at the BWRs of former Asea-Atom design, comprising 9 units in Sweden and Olkiluoto 1 and 2 in Finland, covering years 1983 - 2003. A new logical scheme was developed to classify interconnected failure modes of the two redundant functions for reactivity shutdown, fast hydraulic insertion and slower screw insertion of control rods. The scheme makes an explicit distinction between the different attributes of the failure event: - affected function - affected movement direction - detectability - criticality, i.e. inoperable control rod function versus only degraded functionality Another novel idea emerged for grouping the events according to generic failure mechanism. The generic classes will help to organize and structure the information efficiently, because in most cases within a class, the failure modes prove to be same, or there are only a few alternatives to chose from. From the set of 72 candidate cases, altogether 27 actual or more significant potential CCFs were screened out. Special emphasis was placed to identify any multiple failure or degradation indicating that adjacent rods would be more vulnerable to failure, because such phenomena are far more critical for reactivity shutdown as compared to failure of randomly placed rods. Only slight tendency of position dependence could be determined. Another positive insight is that the events, where foreign objects caused the jamming of rod insertion, were separated by both

  19. Water rod

    International Nuclear Information System (INIS)

    Kashiwai, Shin-ichi; Yokomizo, Osamu; Orii, Akihito.

    1992-01-01

    In a reactor core of a BWR type reactor, the area of a flow channel in a lower portion of a downcoming pipe for downwardly releasing steams present at the top portion in a water rod is increased. Further, a third coolant flow channel (an inner water rod) is disposed in an uprising having an exit opened near the inlet of the water rod and an inlet opened at the outside near the top portion of the water and having an increase flow channel area in the upper portion. The downcoming pipe in the water rod is filled with steams, and the void ratio is increased by so much as the flow channel area of the downcoming pipe is increased. Since the pressure difference between the inlet and the exit of the inner water rod is greater than the pressure difference between the inlet and the exit of the water rod, most of water flown into the inner water rod is discharged out of the exit in the form of water as it is. Since the area of the flow channel is increased in the portion of the inner water rod, void efficiency in the upper portion of the reactor core is decreased by so much. Since the void ratio is thus increased in the lower portion and the void efficiency is decreased in the upper portion of the reactor core, axial void distribution can be flattened. (N.H.)

  20. [Effectiveness of posterior intrasegmental fixation with pedicle screw-lamina hook system in treatment of lumbar spondylolysis].

    Science.gov (United States)

    Zhou, Zhongjie; Song, Yueming; Zeng, Jiancheng; Liu, Hao; Liu, Limin; Kong, Qingquan; Li, Tao; Gong, Quan

    2013-03-01

    To investigate the effectiveness of posterior intrasegmental fixation with pedicle screw-lamina hook system and bone grafting for lumbar spondylolysis. Between January 2005 and October 2009, 22 patients with lumbar spondylolysis underwent posterior intrasegmental fixation with pedicle screw-lamina hook system and bone grafting. There were 19 males and 3 females with an average age of 18.4 years (range, 12-26 years). The main symptom was low back pain with an average disease duration of 16 months (range, 8-56 months). The visual analogue scale (VAS) was 6.0 +/- 1.2 and Oswestry disability index (ODI) was 72.0% +/- 10.0% preoperatively. The X-ray films showed bilateral spondylolysis at L4 in 9 cases and at L5 in 13 cases. The range of motion (ROM) at upper and lower intervertebral spaces was (11.8 +/- 2.8) degrees and (14.1 +/- 1.9) degrees, respectively. All incisions healed by first intention. All patients were followed up 12-45 months (mean, 25 months). Low back pain was significantly alleviated after operation. The VAS score (0.3 +/- 0.5) and ODI (17.6% +/- 3.4%) were significantly decreased at last follow-up when compared with preoperative scores (P spondylolysis, having a high fusion rate, low complication rate, and maximum retention of lumbar ROM.

  1. Design of Cold-Formed Steel Screw Connections with Gypsum Sheathing at Ambient and Elevated Temperatures

    Directory of Open Access Journals (Sweden)

    Wei Chen

    2016-09-01

    Full Text Available Load-bearing cold-formed steel (CFS walls sheathed with double layers of gypsum plasterboard on both sides have demonstrated good fire resistance and attracted increasing interest for use in mid-rise CFS structures. As the main connection method, screw connections between CFS and gypsum sheathing play an important role in both the structural design and fire resistance of this wall system. However, studies on the mechanical behavior of screw connections with double-layer gypsum sheathing are still limited. In this study, 200 monotonic tests of screw connections with single- or double-layer gypsum sheathing at both ambient and elevated temperatures were conducted. The failure of screw connections with double-layer gypsum sheathing in shear was different from that of single-layer gypsum sheathing connections at ambient temperature, and it could be described as the breaking of the loaded sheathing edge combined with significant screw tilting and the loaded sheathing edge flexing fracture. However, the screw tilting and flexing fracture of the loaded sheathing edge gradually disappear at elevated temperatures. In addition, the influence of the loaded edge distance, double-layer sheathing and elevated temperatures is discussed in detail with clear conclusions. A unified design formula for the shear strength of screw connections with gypsum sheathing is proposed for ambient and elevated temperatures with adequate accuracy. A simplified load–displacement model with the post-peak branch is developed to evaluate the load–displacement response of screw connections with gypsum sheathing at ambient and elevated temperatures.

  2. Effect of repeated sterilization by different methods on strength of carbon fiber rods used in external fixator systems.

    Science.gov (United States)

    Unal, Omer Kays; Poyanli, Oguz Sukru; Unal, Ulku Sur; Mutlu, Hasan Huseyin; Ozkut, Afsar Timucin; Esenkaya, Irfan

    2018-05-16

    We set out to reveal the effects of repeated sterilization, using different methods, on the carbon fiber rods of external fixator systems. We used a randomized set of forty-four unused, unsterilized, and identical carbon fiber rods (11 × 200 mm), randomly assigned to two groups: unsterilized (US) (4 rods) and sterilized (40 rods). The sterilized rods were divided into two groups, those sterilized in an autoclave (AC) and by hydrogen peroxide (HP). These were further divided into five subgroups based on the number of sterilization repetition to which the fibers were subjected (25-50-75-100-200). A bending test was conducted to measure the maximum bending force (MBF), maximum deflection (MD), flexural strength (FS), maximum bending moment (MBM) and bending rigidity (BR). We also measured the surface roughness of the rods. An increase in the number of sterilization repetition led to a decrease in MBF, MBM, FS, BR, but increased MD and surface roughness (p < 0.01). The effect of the number of sterilization repetition was more prominent in the HP group. This study revealed that the sterilization method and number of sterilization repetition influence the strength of the carbon fiber rods. Increasing the number of sterilization repetition degrades the strength and roughness of the rods.

  3. Discrete Charge Effects on an Infinitely Long Cylindrical Rod Model

    OpenAIRE

    Agung, Ahmad A. J; Jesudason, Christopher G.

    2011-01-01

    Two methods for determining the potential (\\psi) around a discretely charged rod have been devised. The methods utilize the potential around the continuously charged rod (\\bar{\\psi}) as the reference where \\bar{\\psi} isdetermined by the Poisson-Boltzmann equation. The potential data are used to determine the theoretical radial distribution function (RDF) which is compared with MD simulation data. It is shown that the magnitude of the charge and size parameters very strongly affects the shape ...

  4. Human versus Robot: A Propensity-Matched Analysis of the Accuracy of Free Hand versus Robotic Guidance for Placement of S2 Alar-Iliac (S2AI) Screws.

    Science.gov (United States)

    Shillingford, Jamal N; Laratta, Joseph L; Park, Paul J; Lombardi, Joseph M; Tuchman, Alexander; Saifi, Comron S; Lehman, Ronald A; Lenke, Lawrence G

    2018-04-18

    Retrospective matched cohort analysis. To compare the accuracy of S2 alar-iliac (S2AI) screw placement by robotic guidance versus free hand technique. Spinopelvic fixation utilizing S2AI screws provides optimal fixation across the lumbosacral junction allowing for solid fusion, especially in long segment fusion constructs. Traditionally, S2AI screw placement has required fluoroscopic guidance for accurate screw placement. Herein, we present the first series comparing a free hand and robotic-guided technique for S2AI screw placement. Sixty-eight consecutive patients who underwent S2AI screw placement by either a free hand or robotic technique between 2015 and 2016 were reviewed. Propensity score-matching was utilized to control for preoperative characteristic imbalances. Screw position and accuracy were evaluated using three-dimensional manipulation of CT reconstructions from intraoperative O-arm imaging. A total of 51 patients (105 screws) were matched, 28 (59 screws) in the free hand group (FHG) and 23 (46 screws) in the robot group (RG). The mean age in the FHG and RG were 57.9[REPLACEMENT CHARACTER]± 14.6 years and 61.6[REPLACEMENT CHARACTER]± 12.0 years (P = 0.342), respectively. The average caudal angle in the sagittal plane was significantly larger in the RG (31.0[REPLACEMENT CHARACTER]± 10.0° vs. 25.7[REPLACEMENT CHARACTER]± 8.8°, P =[REPLACEMENT CHARACTER]0.005). There was no difference between the FHG and RG in the horizontal angle, measured in the axial plane using the posterior superior iliac spine (PSIS) as a reference (41.1[REPLACEMENT CHARACTER]± 8.1° vs. 42.8[REPLACEMENT CHARACTER]± 6.6°, P =[REPLACEMENT CHARACTER]0.225), or the S2AI to S1 screw angle (9.4[REPLACEMENT CHARACTER]± 7.0° vs. 11.3[REPLACEMENT CHARACTER]± 9.9°, P =[REPLACEMENT CHARACTER]0.256), respectively. There was no difference in the overall accuracy between FHG and RG (94.9% vs. 97.8%, P =[REPLACEMENT CHARACTER]0.630). Additionally, there

  5. Design and application of leakage monitor for reactor and control rod driving system

    International Nuclear Information System (INIS)

    Li, Dongyu; Zou, Yimin; Ling, Qiu; Guo, Lanying

    2009-04-01

    By measuring the number of γ photons produced by the annihilation of the β + particles of 13 N's decay product in the sample air, the nuclide density of 13 N can be obtained, comparing with its density in the reactor coolant, we can get the leakage information of the reactor vessel and control rod driving system, the article describes the cause of improvement in monitoring for leakage of reactor vessel and control rod driving system of Qinshan Second Nuclear Power Plant (PWR reactor), also the determination of monitoring method and system configuration, as well as the main technical index and function. Furthermore, the main parts and its function of the monitor are introduced. After operation for more than four years, it is proved that both the stability and MTBF index of the monitor meet the design, even more, thanks to the improvement of the algorithm, the Compton Effect caused by other nuclide became neglectable, the MDA of the monitor was lowered also. (authors)

  6. Vibrational characteristics and wear of fuel rods

    International Nuclear Information System (INIS)

    Schmugar, K.L.

    1977-01-01

    Fuel rod wear, due to vibration, is a continuing concern in the design of liquid-cooled reactors. In my report, the methodology and models that are used to predict fuel rod vibrational response and vibratory wear, in a light water reactor environment, are discussed. This methodology is being followed at present in the design of Westinghouse Nuclear Fuel. Fuel rod vibrations are expressed as the normal bending modes, and sources of rod vibration are examined with special emphasis on flow-induced mechanisms in the stable flow region. In a typical Westinghouse PWR fuel assembly design, each fuel rod is supported at multiple locations along the rod axis by a square-shaped 'grid cell'. For a fuel rod /grid support system, the development of small oscillatory motions, due to fluid flow at the rod/grid interface, results in material wear. A theoretical wear mode is developed using the Archard Theory of Adhesive Wear as the basis. Without question certainty, fretting wear becomes a serious problem if it progresses to the stage where the fuel cladding is penetrated and fuel is exposed to the coolant. Westinghouse fuel is designed to minimize fretting wear by limiting the relative motion between the fuel rod and its supports. The wear producing motion between the fuel rod and its supports occurs when the vibration amplitude exceeds the slippage threshold amplitude

  7. Control rod

    International Nuclear Information System (INIS)

    Igarashi, Takao; Yoshimoto, Yuichiro; Sugawara, Satoshi; Fukumoto, Takashi; Endo, Zen-ichiro; Saito, Shozo; Shinpo, Katsutoshi; Nishimura, Akira; Ozawa, Michihiro

    1988-01-01

    Purpose: To provide a sufficient shutdown margin upon reactor shutdown, prevent sheath deformation without decreasing neutron absorbents and prevent impact shocks exerted to structural materials. Constitution: The control rod of the present invention comprises a neutron absorption region, a sheath deformation means attached to the side wall and means for restricting and supporting axial movement of the neutron absorbent rod. Then, the amount of absorptive nuclei chained absorbents in the lower region is reduced than that in the upper region. In this way, effective neutron absorbing performance can be obtained relative to the neutron importance distribution during reactor shutdown. In addition, since the operationability is improved by reducing the weight of the control rod and the absorptive nuclei chained neutron abosrbers are used, mechanical nuclear life of the control rod can be increased. Thus, it is possible to prevent the outward deformation of the sheath, as well as prevent collision between the neutron absorber rod and the structural material on the side of inserting the control rod generated upon reactor scram by a simple structure. (Kamimura, M.)

  8. Azcatl-CRP: An ant colony-based system for searching full power control rod patterns in BWRs

    Energy Technology Data Exchange (ETDEWEB)

    Ortiz, Juan Jose [Dpto. Sistemas Nucleares, ININ, Carr. Mexico-Toluca Km. 36.5, Salazar, Edo. de Mexico (Mexico)]. E-mail: jjortiz@nuclear.inin.mx; Requena, Ignacio [Dpto. Ciencias Computacion e I.A. ETSII Informatica, University of Granada, C. Daniel Saucedo Aranda s/n, 18071 Granada (Spain)]. E-mail: requena@decsai.ugr.es

    2006-01-15

    We show a new system named AZCATL-CRP to design full power control rod patterns in BWRs. Azcatl-CRP uses an ant colony system and a reactor core simulator for this purpose. Transition and equilibrium cycles of Laguna Verde Nuclear Power Plant (LVNPP) reactor core in Mexico were used to test Azcatl-CRP. LVNPP has 109 control rods grouped in four sequences and currently uses control cell core (CCC) strategy in its fuel reload design. With CCC method only one sequence is employed for reactivity control at full power operation. Several operation scenarios are considered, including core water flow variation throughout the cycle, target different axial power distributions and Haling conditions. Azcatl-CRP designs control rod patterns (CRP) taking into account safety aspects such as k {sub eff} core value and thermal limits. Axial power distributions are also adjusted to a predetermined power shape.

  9. Design of active-neutron fuel rod scanner

    International Nuclear Information System (INIS)

    Griffith, G.W.; Menlove, H.O.

    1996-01-01

    An active-neutron fuel rod scanner has been designed for the assay of fissile materials in mixed oxide fuel rods. A 252 Cf source is located at the center of the scanner very near the through hole for the fuel rods. Spontaneous fission neutrons from the californium are moderated and induce fissions within the passing fuel rod. The rod continues past a combined gamma-ray and neutron shield where delayed gamma rays above 1 MeV are detected. We used the Monte Carlo code MCNP to design the scanner and review optimum materials and geometries. An inhomogeneous beryllium, graphite, and polyethylene moderator has been designed that uses source neutrons much more efficiently than assay systems using polyethylene moderators. Layers of borated polyethylene and tungsten are used to shield the detectors. Large NaI(Tl) detectors were selected to measure the delayed gamma rays. The enrichment zones of a thermal reactor fuel pin could be measured to within 1% counting statistics for practical rod speeds. Applications of the rod scanner include accountability of fissile material for safeguards applications, quality control of the fissile content in a fuel rod, and the verification of reactivity potential for mixed oxide fuels. (orig.)

  10. Comparative effect of implant-abutment connections, abutment angulations, and screw lengths on preloaded abutment screw using three-dimensional finite element analysis: An in vitro study.

    Science.gov (United States)

    Kanneganti, Krishna Chaitanya; Vinnakota, Dileep Nag; Pottem, Srinivas Rao; Pulagam, Mahesh

    2018-01-01

    The purpose of this study is to compare the effect of implant-abutment connections, abutment angulations, and screw lengths on screw loosening (SL) of preloaded abutment using three dimensional (3D) finite element analysis. 3D models of implants (conical connection with hex/trilobed connections), abutments (straight/angulated), abutment screws (short/long), and crown and bone were designed using software Parametric Technology Corporation Creo and assembled to form 8 simulations. After discretization, the contact stresses developed for 150 N vertical and 100 N oblique load applications were analyzed, using ABAQUS. By assessing damage initiation and shortest fatigue load on screw threads, the SL for 2.5, 5, and 10 lakh cyclic loads were estimated, using fe-safe program. The obtained values were compared for influence of connection design, abutment angulation, and screw length. In straight abutment models, conical connection showed more damage (14.3%-72.3%) when compared to trilobe (10.1%-65.73%) at 2.5, 5, and 10 lakh cycles for both vertical and oblique loads, whereas in angulated abutments, trilobe (16.1%-76.9%) demonstrated more damage compared to conical (13.5%-70%). Irrespective of the connection type and abutment angulation, short screws showed more percentage of damage compared to long screws. The present study suggests selecting appropriate implant-abutment connection based on the abutment angulation, as well as preferring long screws with more number of threads for effective preload retention by the screws.

  11. [Finite element analysis of stress changes of posterior spinal pedicle screw infixation].

    Science.gov (United States)

    Yan, Jia-Zhi; Wu, Zhi-Hong; Xu, Ri-Xin; Wang, Xue-Song; Xing, Ze-Jun; Zhao, Yu; Zhang, Jian-Guo; Shen, Jian-Xiong; Wang, Yi-Peng; Qiu, Gui-Xing

    2009-01-06

    To evaluate the mechanical response of L3-L4 segment after posterior interfixation with a transpedicle screw system. Spiral CT machine was used to conduct continuous parallel scan on the L3-L4 section of a 40-year-old healthy male Chinese. The image data thus obtained were introduced into MIMICS software to reconstruct the 2-D data into volume data and obtain 3-D models of every element.. Pro/3-D model construction software system was used to simulate the 3-D entity of L3-L4 fixed by screw robs through spinal pedicle via posterior approach that was introduced into the finite element software ABAQUS to construct a 3-D finite element model. The stress changes on the vertebrae and screw under the axial pressure of 0.5 mPa was analyzed. Under the evenly distributed pressure the displacement of the L4 model was 0.00125815 mm, with an error of only 0.8167% from the datum displacement. The convergence of the model was good. The stress of the fixed vertebral body, intervertebral disc, and internal fixators changed significantly. The stress concentration zone of the intervertebral disc turned from the posterolateral side to anterolateral side. The stress produced by the fixed vertebral bodies decreased significantly. Obvious stress concentration existed in the upper and lower sides of the base of screw and the fixed screw at the upper vertebral body bore greater stress than the lower vertebral body. Integration of computer aided device and finite element analysis can successfully stimulate the internal fixation of L3-IA visa posterior approach and observe the mechanic changes in the vertebral column more directly.

  12. A four lumen screwing device for multiparametric brain monitoring.

    Science.gov (United States)

    Feuerstein, T H; Langemann, H; Gratzl, O; Mendelowitsch, A

    2000-01-01

    We describe multiparametric monitoring in severe head trauma using a new screwing device. Our aim was to create a screw which would make the implantation of the probes and thus multiparametric monitoring easier. The new screw allows us to implant 3 probes (microdialysis, Paratrend and an intracranial pressure device) through one burr hole. The screw has four channels, the fourth being for ventricular drainage. We monitored 13 patients with severe head trauma (GCS = 3-8) for up to 7 days. Brain tissue pO2, pCO2, pH, and temperature were measured on-line with the Paratrend 7 machine. The microdialytic parameters glucose, lactate, pyruvate and glutamate were determined semi on-line with a CMA 600 enzymatic analyser. There were no complications in any of the patients that could be ascribed to the screw.

  13. SSYST-1. A computer code system to analyse the fuel rod behaviour during a loss of coolant accident

    International Nuclear Information System (INIS)

    Gulden, W.

    1977-08-01

    The modules of the SSYST program system allow the detailed analysis of an LWR fuel rod in the course of a postulated loss-of-coolant accident. They provide a tool for considering the interaction between the heat conduction in the fuel rod, heat transfer in the gap, fuel and cladding tube deformation, pressure in the coolant, as well as thermal and fluid dynamics in the cooling channel and for calculating the time and location of ballooning and rod failure, respectively. They can be used both to precalculate the behaviour of fuel rods during LWR accidents and in support of the design of experiments. Depending on the problem to be solved, the individual modules can be easily combined. (orig.) [de

  14. Experiments on screw-pinch plasmas with elongated cross section

    International Nuclear Information System (INIS)

    Lassing, H.W.

    1989-01-01

    In this thesis experiments are described carried out with SPICA II, a toroidal screw-pinch plasma device. this device is the last one in a series of plasma machines of the toroidal screw-pinch differing from its predecessor in its race-track shaped section. In devices of the type toroidal screw-pinch stable confinement is possible of plasmas with larger β values than in a tokamak discharge. In a pinch the plasma is screwed up, during the formation, in such a way that in a relatively small volume a plasma is formated with a high pressure. During the screwing up the plasma is heated by shock heating as well as adiabatic compression. With the modified snowplow model the density and temperature after the formation can be calculated, starting from the initial conditions. When all ions arrive into the plasma column, the density in the column is determined by the volume compression. First purpose of the experiments was to find a stable discharge. Subsequently discharges have been made with a high as possible β in order to investigate at which maximum β it is possible to confine screw-pinch plasmas stably. When these had been found, the nature and importance could be investigated of the processes following which the screw-pinch plasma looses its energy. (author), 75 res.; 95 figs.; 8 tabs

  15. Control rod drives

    International Nuclear Information System (INIS)

    Futatsugi, Masao.

    1980-01-01

    Purpose: To secure the reactor operation safety by the provision of a fluid pressure detecting section for control rod driving fluid and a control rod interlock at the midway of the flow pass for supplying driving fluid to the control rod drives. Constitution: Between a driving line and a direction control valve are provided a pressure detecting portion, an alarm generating device, and a control rod inhibition interlock. The driving fluid from a driving fluid source is discharged by way of a pump and a manual valve into the reactor in which the control rods and reactor fuels are contained. In addition, when the direction control valve is switched and the control rods are inserted and extracted by the control rod drives, the pressure in the driving line is always detected by the pressure detection section, whereby if abnormal pressure is resulted, the alarm generating device is actuated to warn the abnormality and the control rod inhibition interlock is actuated to lock the direction control valve thereby secure the safety operation of the reactor. (Seki, T.)

  16. Control rod drives

    International Nuclear Information System (INIS)

    Oonuki, Koji.

    1981-01-01

    Purpose: To increase the driving speed of control rods at rapid insertion with an elongate control rod and an extension pipe while ensuring sufficient buffering performance in a short buffering distance, by providing a plurality of buffers to an extension pipe between a control rod drive source and a control rod in LMFBR type reactor. Constitution: First, second and third buffers are respectively provided to an acceleration piston, an extension pipe and a control rod respectively and the insertion positions for each of the buffers are displaced orderly from above to below. Upon disconnection of energizing current for an electromagnet, the acceleration piston, the extension pipe and the control rod are rapidly inserted in one body. The first, second and third buffers are respectively actuated at each of their falling strokes upon rapid insertion respectively, and the acceleration piston, the extension pipe and the control rod receive the deceleration effect in the order correspondingly. Although the compression force is applied to the control rod only near the stroke end, it does not cause deformation. (Kawakami, Y.)

  17. Determination of Screw and Nail Withdrawal Resistance of Some Important Wood Species

    Directory of Open Access Journals (Sweden)

    Alper Aytekin

    2008-04-01

    Full Text Available In this study, screw and nail withdrawal resistance of fir (Abies nordmanniana, oak (Quercus robur L. black pine (Pinus nigra Arnold and Stone pine (Pinus pinea L. wood were determined and compared. The data represent the testing of withdrawal resistance of three types of screws as smart, serrated and conventional and common nails. The specimens were prepared according to TS 6094 standards. The dimensions of the specimens were 5x5x15cm and for all of the directions. Moreover, the specimens were conditioned at ambient room temperature and 65±2% relative humidity. The screws and nails were installed according to ASTM-D 1761 standards. Nail dimensions were 2.5mm diameter and 50 mm length, conventional screws were 4x50mm, serrated screws were 4x45mm and smart screws were 4x50mm. Results show that the maximum screw withdrawal resistance value was found in Stone pine for the serrated screw. There were no significant differences between Stone pine and oak regarding screw withdrawal resistance values. Conventional screw yielded the maximum screw withdrawal resistance value in oak, followed by Stone pine, black pine and fir. Oak wood showed the maximum screw withdrawal resistance value for the smart screw, followed by Stone pine, black pine, and fir. Oak wood showed higher nail withdrawal resistances than softwood species. It was also determined that oak shows the maximum nail withdrawal resistance in all types. The nail withdrawal resistances at the longitudinal direction are lower with respect to radial and tangential directions.

  18. Enhancement of Orthodontic Anchor Screw Stability Under Immediate Loading by Ultraviolet Photofunctionalization Technology.

    Science.gov (United States)

    Takahashi, Maiko; Motoyoshi, Mitsuru; Inaba, Mizuki; Hagiwara, Yoshiyuki; Shimizu, Noriyoshi

    Ultraviolet (UV)-mediated photofunctionalization technology is intended to enhance the osseointegration capability of titanium implants. There are concerns about orthodontic anchor screws loosening under immediate loading protocols in adolescent orthodontic treatment. The purpose of this in vivo study was to evaluate the effects of photofunctionalization on the intrabony stability of orthodontic titanium anchor screws and bone-anchor screw contact under immediate loading in growing rats. Custom-made titanium anchor screws (1.4 mm in diameter and 4.0 mm in length) with or without photofunctionalization pretreatment were placed on the proximal epiphysis of the tibial bone in 6-week-old male Sprague-Dawley rats and were loaded immediately after placement. After 2 weeks of loading, the stability of the anchor screws was evaluated using a Periotest device, and the bone-anchor screw contact ratio (BSC) was assessed by a histomorphometric analysis using field-emission scanning electron microscopy. In the unloaded group, Periotest values (PTVs) were ~25 for UV-untreated screws and 13 for UVtreated screws (P < .01), while in the immediate-loading group, PTVs were 28 for UV-untreated screws and 16 for UV-treated screws (P < .05). Significantly less screw mobility was observed in both UV-treated groups regardless of the loading protocol. The BSC was increased ~1.8 fold for UV-treated screws, compared with UV-untreated screws, regardless of the loading protocol. Photofunctionalization enhanced the intrabony stability of orthodontic anchor screws under immediate loading in growing rats by increasing bone-anchor screw contact.

  19. The effect of polycrystalline rod insertion in a low Prandtl number melt for continuous Czochralski system

    Science.gov (United States)

    Nam, Phil-Ouk; Son, Seung-Suk; Yi, Kyung-Woo

    2010-04-01

    The increased wafer size results in greater instabilities and complexities within the silicon melt, and melt flow control through the application of magnetic fields is not adequate to stabilize the melt. Therefore, continuous Czochralski systems are being studied as a solution to these issues, with higher productivity and no change in size. The purpose of this study is to observe the effects of polycrystalline rod insertion on the melt for a continuous Czochralski system. In order to observe flow patterns within the melt both broadly and specifically, we employ experimentation on a model system in tandem with numerical simulation. The rod insertion do not significantly affect near the crystal edge. In the melt height from 0.14 to 0.09 m, an asymmetric temperature distributions arise when the crystal rotation is counterclockwise direction (-15 rpm) and the crucible rotation is clockwise direction (3 rpm). The axis-symmetrical temperature distribution is formed at lower melt heights (0.08 and 0.07 m). When the melt height is 0.07 m, the axis-symmetric temperature distribution is maintained even after the rod insertion.

  20. Self-cleaning threaded rod spinneret for high-efficiency needleless electrospinning

    Science.gov (United States)

    Zheng, Gaofeng; Jiang, Jiaxin; Wang, Xiang; Li, Wenwang; Zhong, Weizheng; Guo, Shumin

    2018-07-01

    High-efficiency production of nanofibers is the key to the application of electrospinning technology. This work focuses on multi-jet electrospinning, in which a threaded rod electrode is utilized as the needless spinneret to achieve high-efficiency production of nanofibers. A slipper block, which fits into and moves through the threaded rod, is designed to transfer polymer solution evenly to the surface of the rod spinneret. The relative motion between the slipper block and the threaded rod electrode promotes the instable fluctuation of the solution surface, thus the rotation of threaded rod electrode decreases the critical voltage for the initial multi-jet ejection and the diameter of nanofibers. The residual solution on the surface of threaded rod is cleaned up by the moving slipper block, showing a great self-cleaning ability, which ensures the stable multi-jet ejection and increases the productivity of nanofibers. Each thread of the threaded rod electrode serves as an independent spinneret, which enhances the electric field strength and constrains the position of the Taylor cone, resulting in high productivity of uniform nanofibers. The diameter of nanofibers decreases with the increase of threaded rod rotation speed, and the productivity increases with the solution flow rate. The rotation of electrode provides an excess force for the ejection of charged jets, which also contributes to the high-efficiency production of nanofibers. The maximum productivity of nanofibers from the threaded rod spinneret is 5-6 g/h, about 250-300 times as high as that from the single-needle spinneret. The self-cleaning threaded rod spinneret is an effective way to realize continuous multi-jet electrospinning, which promotes industrial applications of uniform nanofibrous membrane.

  1. Experimental study on the performance of single screw expanders by gap adjustment

    International Nuclear Information System (INIS)

    Wang, Wei; Wu, Yu-ting; Ma, Chong-fang; Xia, Guo-dong; Wang, Jing-fu

    2013-01-01

    Improving thermodynamic efficiency of prime movers is the key issue for efficient utilization of low-temperature heat resources. Single screw expander may be a good candidate because of its many good characteristics. Precisions in manufacture and assembly are very important factors to the performance of single screw expanders. In this paper, the shaft efficiency, volumetric efficiency and gas consumption rate of the single screw expander prototypes were tested and discussed. We have manufactured three prototypes with different gaps to investigate their performance. The first prototype (A) has the largest gap, and the second one (B) has the smallest gap, the third prototype (C) has the medium gap configuration. Experimental result of the prototypes was obtained. From the experimental data of prototype A, the power output was about 5 kW, the gas consumption rate was above 105 kg/kWh and the volumetric efficiency was below 20%, the shaft efficiency was only 34%. From experimental data of prototype B, the mass flow rate was significantly decreased. The power output was only 1.4 kW and the volumetric efficiency was slightly lower than prototype A. The gas consumption rate was much more than that of prototype A. From the experimental data of prototype C, the power output was about 4.5 kW, but the mass flow rate was sharply decreased. The gas consumption rate was about 65 kg/kWh, the maximum volumetric efficiency was about 66%, and the shaft efficiency was about 60%. The experimental results indicated that prototype C of single screw expanders had the best overall performance, which may be further improved by optimizing its configuration. - Highlights: • The experiment for three single screw expander prototypes at different gaps was carried out. • Maximum shaft efficiency is about 60%. • Minimum gas consumption rate is about 65 kg/kWh. • Maximum volumetric efficiency is about 66%. • Leaked gas still has part of working capability

  2. Adjacent-segment disease after thoracic pedicle screw fixation.

    Science.gov (United States)

    Agarwal, Nitin; Heary, Robert F; Agarwal, Prateek

    2018-03-01

    OBJECTIVE Pedicle screw fixation is a technique widely used to treat conditions ranging from spine deformity to fracture stabilization. Pedicle screws have been used traditionally in the lumbar spine; however, they are now being used with increasing frequency in the thoracic spine as a more favorable alternative to hooks, wires, or cables. Although safety concerns, such as the incidence of adjacent-segment disease (ASD) after cervical and lumbar fusions, have been reported, such issues in the thoracic spine have yet to be addressed thoroughly. Here, the authors review the literature on ASD after thoracic pedicle screw fixation and report their own experience specifically involving the use of pedicle screws in the thoracic spine. METHODS Select references from online databases, such as PubMed (provided by the US National Library of Medicine at the National Institutes of Health), were used to survey the literature concerning ASD after thoracic pedicle screw fixation. To include the authors' experience at Rutgers New Jersey Medical School, a retrospective review of a prospectively maintained database was performed to determine the incidence of complications over a 13-year period in 123 consecutive adult patients who underwent thoracic pedicle screw fixation. Children, pregnant or lactating women, and prisoners were excluded from the review. By comparing preoperative and postoperative radiographic images, the occurrence of thoracic ASD and disease within the surgical construct was determined. RESULTS Definitive radiographic fusion was detected in 115 (93.5%) patients. Seven incidences of instrumentation failure and 8 lucencies surrounding the screws were observed. One patient was observed to have ASD of the thoracic spine. The mean follow-up duration was 50 months. CONCLUSIONS This long-term radiographic evaluation revealed the use of pedicle screws for thoracic fixation to be an effective stabilization modality. In particular, ASD seems to be less of a problem in the

  3. Implementation of CTRLPOS, a VENTURE module for control rod position criticality searches, control rod worth curve calculations, and general criticality searches

    Energy Technology Data Exchange (ETDEWEB)

    Smith, L.A.; Renier, J.P.

    1994-06-01

    A module in the VENTURE reactor analysis code system, CTRLPOS, is developed to position control rods and perform control rod position criticality searches. The module is variably dimensioned so that calculations can be performed with any number of control rod banks each having any number of control rods. CTRLPOS can also calculate control rod worth curves for a single control rod or a bank of control rods. Control rod depletion can be calculated to provide radiation source terms. These radiation source terms can be used to predict radiation doses to personnel and estimate the shielding and long-term storage requirements for spent control rods. All of these operations are completely automated. The numerous features of the module are discussed in detail. The necessary input data for the CTRLPOS module is explained. Several sample problems are presented to show the flexibility of the module. The results presented with the sample problems show that the CTRLPOS module is a powerful tool which allows a wide variety of calculations to be easily performed.

  4. Anti-ejection system for control rod drives

    International Nuclear Information System (INIS)

    Matthews, J.C.

    1977-01-01

    A linearly movable latch mechanism is provided to move into engagement with a deformable collet whenever an undesired ejection of a leadscrew is initiated from a nuclear reactor mounted control rod drive. Such an undesired ejection would occur in the event of a rupture in a housing of the control rod drive. The collet is deformed by the linear movement of the latch mechanism to wedge itself against the leadscrew and prevent the ejection of the leadscrew from the housing. The latch mechanism is made to be controllably engageable with the leadscrew and when thus engaged to allow the leadscrew to move in a control direction while moving with the leadscrew to engage and deform the collet when the leadscrew moves in an ejection direction. 13 claims, 2 figures

  5. Fuel rod failure detection method and system

    International Nuclear Information System (INIS)

    Assmann, H.; Janson, W.; Stehle, H.; Wahode, P.

    1975-01-01

    The inventor claims a method for the detection of a defective fuel rod cladding tube or of inleaked water in the cladding tube of a fuel rod in the fuel assembly of a pressurized-water reactor. The fuel assembly is not disassembled but examined as a whole. In the examination, the cladding tube is heated near one of its two end plugs, e.g. with an attached high-frequency inductor. The water contained in the cladding tube evaporates, and steam bubbles or a condensate are detected by the ultrasonic impulse-echo method. It is also possible to measure the delay of the temperature rise at the end plug or to determine the cooling energy required to keep the end plug temperature stable and thus to detect water ingression. (DG/AK) [de

  6. Nuclear reactor fuel rod behavior modelling and current trends

    International Nuclear Information System (INIS)

    Colak, Ue.

    2001-01-01

    Safety assessment of nuclear reactors is carried out by simulating the events to taking place in nuclear reactors by realistic computer codes. Such codes are developed in a way that each event is represented by differential equations derived based on physical laws. Nuclear fuel is an important barrier against radioactive fission gas release. The release of radioactivity to environment is the main concern and this can be avoided by preserving the integrity of fuel rod. Therefore, safety analyses should cover an assessment of fuel rod behavior with certain extent. In this study, common approaches for fuel behavior modeling are discussed. Methods utilized by widely accepted computer codes are reviewed. Shortcomings of these methods are explained. Current research topics to improve code reliability and problems encountered in fuel rod behavior modeling are presented

  7. Local thermal-hydraulic behaviour in tight 7-rod bundles

    International Nuclear Information System (INIS)

    Cheng, X.; Yu, Y.Q.

    2009-01-01

    Advanced water-cooled reactor concepts with tight lattices have been proposed worldwide to improve the fuel utilization and the economic competitiveness. In the present work, experimental investigations were performed on thermal-hydraulic behaviour in tight hexagonal 7-rod bundles under both single-phase and two-phase conditions. Freon-12 was used as working fluid due to its convenient operating parameters. Tests were carried out under both single-phase and two-phase flow conditions. Rod surface temperatures are measured at a fixed axial elevation and in various circumferential positions. Test data with different radial power distributions are analyzed. Measured surface temperatures of unheated rods are used for the assessment of and comparison with numerical codes. In addition, numerical simulation using sub-channel analysis code MATRA and the computational fluid dynamics (CFD) code ANSYS-10 is carried out to understand the experimental data and to assess the validity of these codes in the prediction of flow and heat transfer behaviour in tight rod bundle geometries. Numerical results are compared with experimental data. A good agreement between the measured temperatures on the unheated rod surface and the CFD calculation is obtained. Both sub-channel analysis and CFD calculation indicates that the turbulent mixing in the tight rod bundle is significantly stronger than that computed with a well established correlation.

  8. Development of absorber rod drive mechanisms for PFBR

    International Nuclear Information System (INIS)

    Veerasamy, R.; Dash, S.K.; Natarajan, S.; Rajan, M.; Prabhakar, R.; Kale, R.D.

    1997-01-01

    The Prototype Fast Breeder Reactor has two independent, diverse and fast acting shutdown systems each having its own neutron detectors, logic circuits, drive mechanisms and absorber rods. The respective drive mechanisms are called the control and safety rod drive mechanism and the diverse safety rod drive mechanism. The reliability of the shutdown systems has a direct bearing on the safety of the reactor. Hence a lot of development and testing efforts are required to optimise the design of the drive mechanisms and finally to qualify the same for reactor application. (author)

  9. Screw-Home Movement of the Tibiofemoral Joint during Normal Gait: Three-Dimensional Analysis.

    Science.gov (United States)

    Kim, Ha Yong; Kim, Kap Jung; Yang, Dae Suk; Jeung, Sang Wook; Choi, Han Gyeol; Choy, Won Sik

    2015-09-01

    The purpose of this study was to evaluate the screw-home movement at the tibiofemoral joint during normal gait by utilizing the 3-dimensional motion capture technique. Fifteen young males and fifteen young females (total 60 knee joints) who had no history of musculoskeletal disease or a particular gait problem were included in this study. Two more markers were attached to the subject in addition to the Helen-Hayes marker set. Thus, two virtual planes, femoral coronal plane (P f ) and tibial coronal plane (P t ), were created by Skeletal Builder software. This study measured the 3-dimensional knee joint movement in the sagittal, coronal, and transverse planes of these two virtual planes (P f and P t ) during normal gait. With respect to kinematics and kinetics, both males and females showed normal adult gait patterns, and the mean difference in the temporal gait parameters was not statistically significant (p > 0.05). In the transverse plane, the screw-home movement occurred as expected during the pre-swing phase and the late-swing phase at an angle of about 17°. However, the tibia rotated externally with respect to the femur, rather than internally, while the knee joint started to flex during the loading response (paradoxical screw-home movement), and the angle was 6°. Paradoxical screw-home movement may be an important mechanism that provides stability to the knee joint during the remaining stance phase. Obtaining the kinematic values of the knee joint during gait can be useful in diagnosing and treating the pathological knee joints.

  10. Performance of the NRX shut-off rods

    International Nuclear Information System (INIS)

    Manson, R.E.

    1965-08-01

    A new type of shut-off rod of electromechanical design was developed by the American Machine and Foundry Company for use in the NRX reactor following the accident of 1952. The new rods were installed in May, 1956, as part of the control system conversion program which was completed in 1958. Some problems were encountered with limit switch adjustment but minor modifications in design led to much improved operation. he performance of the rods also improved as more experience was gained in the maintenance and adjustment of the various headgear components. Each headgear is now overhauled once a year on a routine basis. The present design of shut-off rod is considered to be very satisfactory. There has only been one occasion when a shut-off rod has failed to come fully down on a trip. Rods have failed to operate correctly on five other occasions but these occurred during shutdown periods or when the reactor was being shutdown manually. (author)

  11. Nuclear fuel rod end plug weld inspection

    International Nuclear Information System (INIS)

    Parker, M. A.; Patrick, S. S.; Rice, G. F.

    1985-01-01

    Apparatus and method for testing TIG (tungsten inert gas) welds of end plugs on a sealed nuclear reactor fuel rod. An X-ray fluorescent spectrograph testing unit detects tungsten inclusion weld defects in the top end plug's seal weld. Separate ultrasonic weld inspection system testing units test the top end plug's seal and girth welds and test the bottom end plug's girth weld for penetration, porosity and wall thinning defects. The nuclear fuel rod is automatically moved into and out from each testing unit and is automatically transported between the testing units by rod handling devices. A controller supervises the operation of the testing units and the rod handling devices

  12. Preoperative CT planning of screw length in arthroscopic Latarjet.

    Science.gov (United States)

    Hardy, Alexandre; Gerometta, Antoine; Granger, Benjamin; Massein, Audrey; Casabianca, Laurent; Pascal-Moussellard, Hugues; Loriaut, Philippe

    2018-01-01

    The Latarjet procedure has shown its efficiency for the treatment of anterior shoulder dislocation. The success of this technique depends on the correct positioning and fusion of the bone block. The length of the screws that fix the bone block can be a problem. They can increase the risk of non-union if too short or be the cause of nerve lesion or soft tissue discomfort if too long. Suprascapular nerve injuries have been reported during shoulder stabilisation surgery up to 6 % of the case. Bone block non-union depending on the series is found around 20 % of the cases. The purpose of this study was to evaluate the efficiency of this CT preoperative planning to predict optimal screws length. The clinical importance of this study lies in the observation that it is the first study to evaluate the efficiency of CT planning to predict screw length. Inclusion criteria were patients with chronic anterior instability of the shoulder with an ISIS superior to 4. Exclusion criteria were patients with multidirectional instability or any previous surgery on this shoulder. Thirty patients were included prospectively, 11 of them went threw a CT planning, before their arthroscopic Latarjet. Optimal length of both screws was calculated, adding the size of the coracoid at 5 and 15 mm from the tip to the glenoid. Thirty-two-mm screws were used for patients without planning. On a post-operative CT scan with 3D reconstruction, the distance between the screw tip and the posterior cortex was measured. A one-sample Wilcoxon test was used to compare the distance from the tip of the screw to an acceptable positioning of ±2 mm from the posterior cortex. In the group without planning, screw 1 tended to differ from the acceptable positioning: mean 3.44 mm ± 3.13, med 2.9 mm, q1; q3 [0.6; 4.75] p = 0.1118, and screw 2 differed significantly from the acceptable position: mean 4.83 mm ± 4.11, med 3.7 mm, q1; q3 [1.7; 5.45] p = 0.0045. In the group with planning, position of

  13. Usefulness and radiological evaluation of accuracy of innovative "Smart" hand technique for pedicle screw placement: an anatomical study.

    Science.gov (United States)

    Comert, Ayhan; Dogan, İhsan; Çaglar, Y Sukru

    2017-11-01

    The aim of this study is to use a smartphone application during pedicle screw placement navigation and examine the accuracy of this application on anatomical dry vertebrae model. 76 dry vertebrae were used for this study and pedicle entry points, projections of pedicle screw trajectory lines in lateral and superior aspect of vertebral body were identified and drawn for each vertebra bilaterally. In each position, all angulations were measured directly before the procedure manually. 152 pedicle screws were inserted as a simulation of screw placement with the guidance of angle-meter smart app. Accuracy of the method was tested according to the occurrence of bone penetration and angular deviation of the inserted screws was evaluated in computed tomography images. Mean deviation of pedicle screws of 76 pedicle screws in right side in horizontal plane was measured 2.30°±1.78°; in sagittal plane 2.17°±1.57° and in left side in horizontal plane 3.01°±1.83°; in sagittal plane 2.38°±1.68°. No bone penetration was occurred during 152 pedicle screw placements. According to the t-test results, there were significant differences between two groups in craniocaudal direction of the right side pedicle screws and in craniocaudal direction of left side pedicle screws. The free smartphone application presented here as angle-meter can be interpreted as a safe digital device for spinal instrumentation procedures. As a prototype of future pedicle screw fixation systems, it should be improved in terms of its feasibility and compatibility with screw probes. This may lead to apply mobile digital angle meter in spinal procedure.

  14. The influence of specific mechanical energy on cornmeal viscosity measured by an on-line system during twin-screw extrusion

    OpenAIRE

    CHANG, Y. K.; MARTINEZ-BUSTOS, F.; PARK, T. S.; KOKINI, J .L.

    1999-01-01

    The influence of specific mechanical energy (SME) on cornmeal viscosity during the twin-screw extrusion at feed moisture contents of 25 and 30% and screw speeds in the range from 100 to 500 rpm was measured. Cornmeal was extruded in a co-rotating, intermeshing twin-screw coupled to a slit die rheometer. One approach to the on-line rheological measurement is to use a slit die with the extruder. In the present work it was show that shear viscosity decreased as a function of SME. The viscosity o...

  15. Aging mechanisms in the Westinghouse PWR [Pressurized Water Reactor] Control Rod Drive system

    International Nuclear Information System (INIS)

    Gunther, W.; Sullivan, K.

    1991-01-01

    An aging assessment of the Westinghouse Pressurized Water Reactor (PWR) Control Rod System (CRD) has been completed as part of the US NRC's Nuclear Plant Aging Research, (NPAR) Program. This study examined the design, construction, maintenance, and operation of the system to determine its potential for degradation as the plant ages. Selected results from this study are presented in this paper. The operating experience data were evaluated to identify the predominant failure modes, causes, and effects. From our evaluation of the data, coupled with an assessment of the materials of construction and the operating environment, we conclude that the Westinghouse CRD system is subject to degradation which, if unchecked, could affect its safety function as a plant ages. Ways to detect and mitigate the effects of aging are included in this paper. The current maintenance for the control rod drive system at fifteen Westinghouse PWRs was obtained through a survey conducted in cooperation with EPRI and NUMARC. The results of the survey indicate that some plants have modified the system, replaced components, or expanded preventive maintenance. Several of these activities have effectively addressed the aging issue. 2 refs., 2 figs., 2 tabs

  16. [Clinical efficacy of unilateral percutaneous transfacet screws combined with contralateral pedicle screw versus bilateral pedicle screws fixation in the treatment of the degenerative lumbar disease].

    Science.gov (United States)

    Hao, Rong-Xue; Zhou, Hui; Pan, Hao; Yue, Jun; Chen, Hui-Guo; Yang, He-Jie; Jia, Gao-Yong; Wang, Dong; Lin, Yan; Xu, Hua-Zi

    2017-09-25

    To investigate the surgical outcome of unilateral pedicle screw(UPS) after TLIF technique combined with contralateral percutaneous transfacet screw(PTS) fixation vs bilateral pedicle screws(BPS) fixation in treatment of degenerative lumbar disease. From January 2009 to June 2012, 46 patients with degenerative lumbar diseases, including 30 males and 16 females with an average age of 51.5 years old, who were divided into two groups according to different fixation methods. Twenty-two cases underwent UPS after TLIF technique combined with contralateral PTS fixation (group A), while the others underwent BPS fixation(group B). The relative data were analyzed, such as blood loss volume, operative time, fusion rate, ODI score, JOA score and so on. All the patients were followed up for 1 to 3 years with an average of 22 months. Except one case of each group was uncertainty fusion, the rest have obtained bony fusion, and the fusion rates in group A and B were 95.5% and 95.8%, respectively. No displacement and breakage of screw were found during follow-up. Operative time and blood loss volume in group A were better than of group B( P 0.05). Two approaches had similar clinical outcomes for degenerative lumbar disease with no severe instability. Compared with BPS fixation, the UPS after TLIF technique and contralateral PTS fixation has the advantages of less trauma, shorter operative time and less blood loss, and it is a safe and feasible surgical technique.

  17. Multiaxial pedicle screw designs: static and dynamic mechanical testing.

    Science.gov (United States)

    Stanford, Ralph Edward; Loefler, Andreas Herman; Stanford, Philip Mark; Walsh, William R

    2004-02-15

    Randomized investigation of multiaxial pedicle screw mechanical properties. Measure static yield and ultimate strengths, yield stiffness, and fatigue resistance according to an established model. Compare these measured properties with expected loads in vivo. Multiaxial pedicle screws provide surgical versatility, but the complexity of their design may reduce their strength and fatigue resistance. There is no published data on the mechanical properties of such screws. Screws were assembled according to a vertebrectomy model for destructive mechanical testing. Groups of five assemblies were tested in static tension and compression and subject to three cyclical loads. Modes of failure, yield, and ultimate strength, yield stiffness, and cycles to failure were determined for six designs of screw. Static compression yield loads ranged from 217.1 to 388.0 N and yield stiffness from 23.7 to 38.0 N/mm. Cycles to failure ranged from 42 x 10(3) to 4,719 x 10(3) at 75% of static ultimate load. There were significant differences between designs in all modes of testing. Failure occurred at the multiaxial link in static and cyclical compression. Bending yield strengths just exceeded loads expected in vivo. Multiaxial designs had lower static bending yield strength than fixed screw designs. Five out of six multiaxial screw designs achieved one million cycles at 200 N in compression bending. "Ball-in-cup" multiaxial locking mechanisms were vulnerable to fatigue failure. Smooth surfaces and thicker material appeared to be protective against fatigue failure.

  18. Release of metal in vivo from stressed and nonstressed maxillofacial fracture plates and screws.

    Science.gov (United States)

    Matthew, I R; Frame, J W

    2000-07-01

    To analyze the release of metal into the adjacent tissues from stressed and nonstressed titanium and stainless steel miniplates and screws. Two miniplates were inserted into the cranial vaults of 12 beagle dogs while they were under general endotracheal anesthesia. One miniplate was shaped to fit the curvature of the skull (control). Another miniplate, made of the same material, was bent in a curve until the midpoint was raised 3 mm above the ends. Screws were inserted and tightened until the plate conformed to the skull curvature, creating stresses in the system. Four animals (2 each, having titanium or stainless steel plates and screws) were killed after 4, 12, and 24 weeks. Metallosis of adjacent soft tissues was assessed qualitatively. Miniplates and screws were removed, and adjacent soft tissue and bone was excised. Titanium, iron, chromium, nickel, and aluminum levels were assayed by ultraviolet/visible light and atomic absorption spectrophotometry. Nonparametric statistical methods were used for data analysis. There was no clear relationship between pigmentation of soft tissue adjacent to the miniplates and screws and the concentrations of metal present. The data did not demonstrate any consistent differences in the concentrations of metallic elements next to stressed and nonstressed (control) miniplates and screws of either material. Stresses arising through poor contouring of miniplates do not appear to influence the extent of release of metal into the adjacent tissues.

  19. The Invasive Species Forecasting System (ISFS): An iRODS-Based, Cloud-Enabled Decision Support System for Invasive Species Habitat Suitability Modeling

    Science.gov (United States)

    Gill, Roger; Schnase, John L.

    2012-01-01

    The Invasive Species Forecasting System (ISFS) is an online decision support system that allows users to load point occurrence field sample data for a plant species of interest and quickly generate habitat suitability maps for geographic regions of interest, such as a national park, monument, forest, or refuge. Target customers for ISFS are natural resource managers and decision makers who have a need for scientifically valid, model- based predictions of the habitat suitability of plant species of management concern. In a joint project involving NASA and the Maryland Department of Natural Resources, ISFS has been used to model the potential distribution of Wavyleaf Basketgrass in Maryland's Chesapeake Bay Watershed. Maximum entropy techniques are used to generate predictive maps using predictor datasets derived from remotely sensed data and climate simulation outputs. The workflow to run a model is implemented in an iRODS microservice using a custom ISFS file driver that clips and re-projects data to geographic regions of interest, then shells out to perform MaxEnt processing on the input data. When the model completes, all output files and maps from the model run are registered in iRODS and made accessible to the user. The ISFS user interface is a web browser that uses the iRODS PHP client to interact with the ISFS/iRODS- server. ISFS is designed to reside in a VMware virtual machine running SLES 11 and iRODS 3.0. The ISFS virtual machine is hosted in a VMware vSphere private cloud infrastructure to deliver the online service.

  20. Heat transfer coefficient testing in nuclear fuel rod bundles with mixing vane grids

    International Nuclear Information System (INIS)

    Conner, Michael E.; Smith, L. David III; Holloway, Mary V.; Beasley, Donald E.

    2005-01-01

    An air heat transfer test facility was developed to test the heat transfer downstream of support grids in simulated PWR nuclear fuel rod bundles. The goal of this testing is to study the single-phase heat transfer coefficients downstream of grids with mixing vanes in a square-pitch rod bundle. The technique developed utilizes fully-heated grid spans and a specially designed thermocouple holder that can be moved axially down the rod bundle and aximuthally within a test rod. From this testing, the axial and aximuthally varying heat transfer coefficient can be determined. Different grid designs are tested and compared to determine the heat transfer enhancement associated with key grid features such as mixing vanes. (author)

  1. Control rod drive mechanism

    International Nuclear Information System (INIS)

    Nakamura, Akira.

    1981-01-01

    Purpose: To ensure the scram operation of a control rod by the reliable detection for the position of control rods. Constitution: A permanent magnet is provided to the lower portion of a connecting rod in engagement with a control rod and a tube having a plurality of lead switches arranged axially therein in a predetermined pitch is disposed outside of the control rod drives. When the control rod moves upwardly in the scram operation, the lead switches are closed successively upon passage of the permanent magnet to operate the electrical circuit provided by way of each of the lead switches. Thus, the position for the control rod during the scram can reliably be determined and the scram characteristic of the control rod can be recognized. (Furukawa, Y.)

  2. On Helical Projection and Its Application in Screw Modeling

    Directory of Open Access Journals (Sweden)

    Riliang Liu

    2014-04-01

    Full Text Available As helical surfaces, in their many and varied forms, are finding more and more applications in engineering, new approaches to their efficient design and manufacture are desired. To that end, the helical projection method that uses curvilinear projection lines to map a space object to a plane is examined in this paper, focusing on its mathematical model and characteristics in terms of graphical representation of helical objects. A number of interesting projective properties are identified in regard to straight lines, curves, and planes, and then the method is further investigated with respect to screws. The result shows that the helical projection of a cylindrical screw turns out to be a Jordan curve, which is determined by the screw's axial profile and number of flights. Based on the projection theory, a practical approach to the modeling of screws and helical surfaces is proposed and illustrated with examples, and its possible application in screw manufacturing is discussed.

  3. Development and Testing of X-Ray Imaging-Enhanced Poly-L-Lactide Bone Screws.

    Directory of Open Access Journals (Sweden)

    Wei-Jen Chang

    Full Text Available Nanosized iron oxide particles exhibit osteogenic and radiopaque properties. Thus, iron oxide (Fe3O4 nanoparticles were incorporated into a biodegradable polymer (poly-L-lactic acid, PLLA to fabricate a composite bone screw. This multifunctional, 3D printable bone screw was detectable on X-ray examination. In this study, mechanical tests including three-point bending and ultimate tensile strength were conducted to evaluate the optimal ratio of iron oxide nanoparticles in the PLLA composite. Both injection molding and 3D printing techniques were used to fabricate the PLLA bone screws with and without the iron oxide nanoparticles. The fabricated screws were implanted into the femoral condyles of New Zealand White rabbits. Bone blocks containing the PLLA screws were resected 2 and 4 weeks after surgery. Histologic examination of the surrounding bone and the radiopacity of the iron-oxide-containing PLLA screws were evaluated. Our results indicated that addition of iron oxide nanoparticles at 30% significantly decreased the ultimate tensile stress properties of the PLLA screws. The screws with 20% iron oxide exhibited strong radiopacity compared to the screws fabricated without the iron oxide nanoparticles. Four weeks after surgery, the average bone volume of the iron oxide PLLA composite screws was significantly greater than that of PLLA screws without iron oxide. These findings suggested that biodegradable and X-ray detectable PLLA bone screws can be produced by incorporation of 20% iron oxide nanoparticles. Furthermore, these screws had significantly greater osteogenic capability than the PLLA screws without iron oxide.

  4. Biomechanical properties of a novel biodegradable magnesium-based interference screw

    Directory of Open Access Journals (Sweden)

    Marco Ezechieli

    2016-06-01

    Full Text Available Magnesium-based interference screws may be an alternative in anterior/posterior cruciate ligament reconstruction. The well-known osteoconductive effects of biodegradable magnesium alloys may be useful. It was the purpose of this study to evaluate the biomechanical properties of a magnesium based interference screw and compare it to a standard implant. A MgYREZr-alloy interference screw and a standard implant (Milagro®; De Puy Mitek, Raynham, MA, USA were used for graft fixation. Specimens were placed into a tensile loading fixation of a servohydraulic testing machine. Biomechanical analysis included pretensioning of the constructs at 20 N for 1 min following cyclic pretensioning of 20 cycles between 20 and 60 N. Biomechanical elongation was evaluated with cyclic loading of 1000 cycles between 50 and 200 N at 0.5 Hz. Maximum load to failure was 511.3±66.5 N for the Milagro® screw and 529.0±63.3 N for magnesium-based screw (ns, P=0.57. Elongations after preload, during cyclical loading and during failure load were not different between the groups (ns, P>0.05. Stiffness was 121.1±13.8 N/mm for the magnesiumbased screw and 144.1±18.4 for the Milagro® screw (ns, P=0.32. MgYREZr alloy interference screws show comparable results in biomechanical testing to standard implants and may be an alternative for anterior cruciate reconstruction in the future.

  5. Cost targets for at-reactor spent fuel rod consolidation

    International Nuclear Information System (INIS)

    Macnabb, W.V.

    1985-01-01

    The high-level nuclear waste management system in the US currently envisions the disposal of spent fuel rods that have been removed from their assemblies and reconfigured into closely packed arrays. The process of fuel rod removal and packaging, referred to as rod consolidation, can occur either at reactors or at an integrated packaging facility, monitored retrievable storage (MRS). Rod consolidation at reactors results in cost savings down stream of reactors by reducing needs for additional storage, reducing the number of shipments, and reducing (eliminating, in the extreme) the amount of fuel handling and consolidation at the MRS. These savings accrue to the nuclear waste fund. Although private industry is expected to pay for at-reactor activities, including rod consolidation, it is of interest to estimate cost savings to the waste system if all fuel were consolidated at reactors. If there are savings, the US Department of Energy (DOE) may find it advantageous to pay for at-reactor rod consolidation from the nuclear waste fund. This paper assesses and compares the costs of rod consolidation at reactors and at the MRS in order to determine at what levels the former could be cost competitive with the latter

  6. Study on the quantitative rod internal pressure design criterion

    International Nuclear Information System (INIS)

    Kim, Kyu Tae; Kim, Oh Hwan; Han, Hee Tak

    1991-01-01

    The current rod internal pressure criterion permits fuel rods to operate with internal pressures in excess of system pressure only if internal overpressure does not cause the diametral gap enlargement. In this study, the generic allowable internal gas pressure not violating this criterion is estimated as a function of rod power. The results show that the generic allowable internal gas pressure decreases linearly with the increase of rod power. Application of the generic allowable internal gas pressure for the rod internal pressure design criterion will result in the simplication of the current design procedure for checking the diametral gap enlargement caused by internal overpressure because according to the current design procedure the cladding creepout rate should be compared with the fuel swelling rate at each axial node at each time step whenever internal pressure exceeds the system pressure. (Author)

  7. RODMOD: a code for control rod positioning

    International Nuclear Information System (INIS)

    Vondy, D.R.; Fowler, T.B.

    1978-11-01

    The report documents a computer code which has been implemented to position control rods according to a prescribed schedule during the calculation of a reactor history. Control rods may be represented explicitly with or without internal black absorber conditions in selected energy groups, or fractional insertion may be done, or both, in a problem. There is provision for control rod follower, movement of materials through a series of zones in a closed loop, and shutdown rod insertion and subsequent removal to allow the reactor history calculation to be continued. This code is incorporated in the system containing the VENTURE diffusion theory neutronics and the BURNER exposure codes for routine use. The implemented automated procedures cause the prescribed control rod insertion schedule to be applied without the access of additional user input data during the calculation of a reactor operating history

  8. Application of an expandable pedicle screw in the severe osteoporotic spine: a preliminary study.

    Science.gov (United States)

    Wu, Zi-xiang; Cui, Geng; Lei, Wei; Fan, Yong; Wan, Shi-yong; Ma, Zhen-sheng; Sang, Hong-xun

    2010-12-01

    To investigate the clinical abstract and radiographic outcome of multi-axial expandable pedicle screws (MEPS) in patients with osteoporosis. One hundred and twenty-five consecutive patients received MEPS from the UPASS spinal fixation system to obtain thoracolumbar or lumbosacral stabilization. All patients underwent bone mineral density (BMD) scans. The indications for use of the MEPS were spinal diseases with severe osteoporosis (degenerative diseases 46 cases, compression fractures 28 cases, lumbar tuberculosis 27 cases and revision spine surgery 24 cases). The pre-operative and three months post-operative functional evaluations were graded with JOA and VAS scoring system. One week, six months and 12 months after surgery, plain film and three-dimensional CT scans were obtained to evaluate the spinal fusion and fixation effectiveness of MEPS. The mean follow-up period was 18 months (ranged from 6 to 33 months). All patients suffered from severely osteoporosis with a decrease of 25.3% in BMD. The pre-operative JOA and VAS scores were 11.3±3.0 and 6.7±1.8 mm, respectively. Three months after operation, the JOA and VAS scores were 25.2±2.0 and 2.3±1.7 mm. The recovery rate was 78.1±11.5% and the clinical results were satisfying. There were no instances of screw loosening or pullout of the MEPS and the screw-bone interface was excellent. The radiographic results showed that bone healing, both around the screws and inter-vertebral, was achieved. In osteoporosis spine surgery, excellent bone-screw interface and fixation strength can be achieved by using MEPS. MEPS are a novel approach to increase the pedicle screw fixation in osteoporotic and revision spine surgeries.

  9. Mechanical characteristics of connection for GFRP plates using tapping screws

    Science.gov (United States)

    Inoue, Yuya; Duong, Nguyen Ngoc; Satake, Chito; Matsumoto, Yukihiro

    2017-10-01

    FRP material has good characteristics such as light-weight, high-strength and high-corrosion resistance. Light-weight structure possesses some advantages over the rational constructing procedure such as self-building structures. In recent years, mechanical characteristics of FRP joints using bolts and/or rivet are investigated in detail, and they are used in many FRP structures. However, the bolts lack bearing strength compared with material strength and the joint needs the prepared bolt hole. In this paper, an alternative joint system for FRP structures using tapping screw is proposed and mechanical characteristics are investigated through experiment. Tapping screw has some advantages; easy-to-use, light-weight and high bearing strength. Then, the results of double-lapped tensile shear tests having one, four and eight tapping screws along longitudinal direction are shown. Moreover, it is shown that longitudinal stress distribution is approximately corresponding to the theoretical stress distribution of double-lapped adhesively bonded joints. Based on these, it is proposed that joint strength can be estimated by using the present calculation method.

  10. The Eclipse system for surveying the guide tubes of control rod clusters

    International Nuclear Information System (INIS)

    Pace, Y.M.

    2008-01-01

    Eclipse is a new system developed by Areva to assess the wear of the guide tubes of control rod clusters. This system is based on the projection of a shadow on a light plan in order to record the profile and the internal diameter of a hollow tube. This system allows us to quantify the wear and it can be included in a program dedicated to monitor the wear and master its kinetics. This system has been validated on the guide tubes from the Ringhals units. (A.C.)

  11. Control rod drives

    International Nuclear Information System (INIS)

    Hayakawa, Hiroyasu.

    1979-01-01

    Purpose: To enable rapid control in a simple circuit by providing a motor control device having an electric capacity capable of simultaneously driving all of the control rods rapidly only in the inserting direction as well as a motor controlling device capable of fine control for the insertion and extraction at usual operation. Constitution: The control rod drives comprise a first motor control device capable of finely controlling the control rods both in inserting and extracting directions, a second motor control device capable of rapidly driving the control rods only in the inserting direction, and a first motor switching circuit and a second motor switching circuit switched by switches. Upon issue of a rapid insertion instruction for the control rods, the second motor switching circuit is closed by the switch and the second motor control circuit and driving motors are connected. Thus, each of the control rod driving motors is driven at a high speed in the inserting direction to rapidly insert all of the control rods. (Yoshino, Y.)

  12. Double throat pressure pulsation dampener for oil-free screw compressors

    Science.gov (United States)

    Lucas, Michael J.

    2005-09-01

    This paper describes a recent invention at Ingersoll-Rand for reducing the pressure pulsations in an oil-free screw compressor. Pressure pulsation is a term used in the air compressor industry to describe the rapid change in pressure with time measured in the downstream piping of the air compressor. The pulsations are due to the rapid opening and closing of the screws as the compressed air is eject from the compressor into the piping system. The pulsations are known to produce excessive noise levels and high levels of vibration in the piping system. Reducing these pulsations is critical to achieving a quiet running compressor. This paper will describe the methodology used to analyze the data and show both computational and experimental results achieved using the pulsation dampener. A patent for this design has been filed with the US patent office.

  13. Effects on Subtalar Joint Stress Distribution After Cannulated Screw Insertion at Different Positions and Directions.

    Science.gov (United States)

    Yuan, Cheng-song; Chen, Wan; Chen, Chen; Yang, Guang-hua; Hu, Chao; Tang, Kang-lai

    2015-01-01

    We investigated the effects on subtalar joint stress distribution after cannulated screw insertion at different positions and directions. After establishing a 3-dimensional geometric model of a normal subtalar joint, we analyzed the most ideal cannulated screw insertion position and approach for subtalar joint stress distribution and compared the differences in loading stress, antirotary strength, and anti-inversion/eversion strength among lateral-medial antiparallel screw insertion, traditional screw insertion, and ideal cannulated screw insertion. The screw insertion approach allowing the most uniform subtalar joint loading stress distribution was lateral screw insertion near the border of the talar neck plus medial screw insertion close to the ankle joint. For stress distribution uniformity, antirotary strength, and anti-inversion/eversion strength, lateral-medial antiparallel screw insertion was superior to traditional double-screw insertion. Compared with ideal cannulated screw insertion, slightly poorer stress distribution uniformity and better antirotary strength and anti-inversion/eversion strength were observed for lateral-medial antiparallel screw insertion. Traditional single-screw insertion was better than double-screw insertion for stress distribution uniformity but worse for anti-rotary strength and anti-inversion/eversion strength. Lateral-medial antiparallel screw insertion was slightly worse for stress distribution uniformity than was ideal cannulated screw insertion but superior to traditional screw insertion. It was better than both ideal cannulated screw insertion and traditional screw insertion for anti-rotary strength and anti-inversion/eversion strength. Lateral-medial antiparallel screw insertion is an approach with simple localization, convenient operation, and good safety. Copyright © 2015 American College of Foot and Ankle Surgeons. Published by Elsevier Inc. All rights reserved.

  14. Electromagnetic Lead Screw for Potential Wave Energy Application

    DEFF Research Database (Denmark)

    Lu, Kaiyuan; Wu, Weimin

    2014-01-01

    This paper presents a new type electromagnetic lead screw (EMLS) intended for wave energy application. Similar to the mechanical lead screw, this electromagnetic version can transfer slow linear motion to high-rotational motion, offering gearing effects. Compared with the existing pure magnetic...

  15. Method and apparatus for compacting spent nuclear reactor fuel rods

    International Nuclear Information System (INIS)

    Wachter, W.J.

    1988-01-01

    In a nuclear reactor system requiring periodic physical manipulation of spent fuel rods, the method of compacting fuel rods from a fuel rod assembly is described comprising the steps of: (1) removing the top end from pulling members having electrodes of weld elements in leading ends thereof in sequence through a fuel rod container and thence through respective consolidating passages in a fuel-rod directing chamber; (3) welding the weld elements of the pulling members to the top end of respective fuel rods corresponding to the respective pulling members; (4) drawing each of the pulling members axially to draw the respective engaged fuel rods in one axial direction through the respective passages in the chamber to thereby consolidate the fuel rods into a compacted configuration of a cross-sectional area smaller than the cross-sectional area occupied thereby within the fuel rod assembly; and (5) drawing all of the engaged fuel rods concurrently and substantially parallel to one another to the one axial direction into the fuel rod container while maintaining the compacting configuration in a fuel rod density which is greater than that of the fuel rod density of the fuel rod assembly

  16. Fission reactor control rod

    International Nuclear Information System (INIS)

    Irie, Tomoo.

    1991-01-01

    The present invention concerns a control rod in a PWR type reactor. A control rod has an inner cladding tube and an outer cladding tube disposed coaxially, and a water draining hole is formed at the inside of the inner cladding tube. Neutron absorbers are filled in an annular gap between the outer cladding tube and the inner cladding tube. The water draining hole opens at the lower end thereof to the top end of the control rod and at the upper end thereof to the side of the upper end plug of the control rod. If the control rod is dropped to a control rod guide thimble for reactor scram, coolants from the control rod guide thimble are flown from the lower end of the water draining hole and discharged from the upper end passing through the water draining hole. In this way, water from the control rod guide thimble is removed easily when the control rod is dropped. Further, the discharging amount of water itself is reduced by the provision of the water draining hole. Accordingly, sufficient control rod dropping speed can be attained. (I.N.)

  17. Fuel rod simulator effects in flooding experiments single rod tests

    International Nuclear Information System (INIS)

    Nishida, M.

    1984-09-01

    The influence of a gas filled gap between cladding and pellet on the quenching behavior of a PWR fuel rod during the reflood phase of a LOCA has been investigated. Flooding experiments were conducted with a short length electrically heated single fuel rod simulator surrounded by glass housing. The gap of 0.05 mm width between the Zircaloy cladding and the internal Al 2 O 3 pellets of the rod was filled either wit helium or with argon to vary the radial heat resistance across the gap. This report presents some typical data and an evaluation of the reflood behavior of the fuel rod simulator used. The results show that the quench front propagates faster for increasing heat resistance in the gap between cladding and heat source of the rod. (orig.) [de

  18. Prototypical Rod Consolidation Demonstration Project

    International Nuclear Information System (INIS)

    1993-05-01

    The objective of Phase 3 of the Prototypical Rod consolidation Demonstration Project (PRCDP) was to procure, fabricate, assemble, and test the Prototypical Rod consolidation System as described in the NUS Phase 2 Final Design Report. This effort required providing the materials, components, and fabricated parts which makes up all of the system equipment. In addition, it included the assembly, installation, and setup of this equipment at the Cold Test Facility. During the Phase 3 effort the system was tested on a component, subsystem, and system level. This volume 1, discusses the PRCDP Phase 3 Test Program that was conducted by the HALLIBURTON NUS Environmental Corporation under contract AC07-86ID12651 with the United States Department of Energy. This document, Volume 1, Book 8 discusses Control System SOT Tests Results and Analysis Report. This is a continuation of Book 7

  19. Bioresorbable screws reinforced with phosphate glass fibre: manufacturing and mechanical property characterisation.

    Science.gov (United States)

    Felfel, R M; Ahmed, I; Parsons, A J; Rudd, C D

    2013-01-01

    Use of bioresorbable screws could eliminate disadvantages associated with metals such as removal operations, corrosion, MRI interference and stress shielding. Mechanical properties of bioresorbable polymers alone are insufficient for load bearing applications application as screws. Thus, reinforcement is necessary to try and match or surpass the mechanical properties of cortical bone. Phosphate based glass fibres were used to reinforce polylactic acid (PLA) in order to produce unidirectionally aligned (UD) and unidirectionally plus randomly distributed (UD/RM) composite screws (P40 UD and P40 UD/RM). The maximum flexural and push-out properties for the composite screws (P40 UD and P40 UD/RM) increased by almost 100% in comparison with the PLA screws. While the pull-out strength and stiffness of the headless composite screws were ∼80% (strength) and ∼130% (stiffness) higher than for PLA, those with heads exhibited properties lower than those for PLA alone as a result of failure at the heads. An increase in the maximum shear load and stiffness for the composite screws (∼30% and ∼40%) in comparison to the PLA screws was also seen. Maximum torque for the PLA screws was ∼1000 mN m, while that for the composite screws were slightly lower. The SEM micrographs for P40 UD and P40 UD/RM screws revealed small gaps around the fibres, which were suggested to be due to buckling of the UD fibres during the manufacturing process. Copyright © 2012 Elsevier Ltd. All rights reserved.

  20. Process and apparatus for optimizing screwing position for closure stud

    International Nuclear Information System (INIS)

    Bourdonne, J.C.; Briand, A.

    1987-01-01

    The stud is fixed to a screwing and unscrewing device. The vertical position and alignment of the stud with the axis of the threated hole is checking. The stud is descended into the hole and rotated in the unscrewing direction. After detection of the point of engagement, the stud is rotated in the screwing direction. When a gamming is detected the descent is stopped and the screwing device is positioned in a new position. When the screwing couple returns below the disconnection couple, the stud is rotated with a reduced speed and then with a normal speed until the end [fr

  1. Grid deformation strategies for CFD analysis of screw compressors

    OpenAIRE

    Rane, S.; Kovacevic, A.; Stosic, N.; Kethidi, M.

    2013-01-01

    Customized grid generation of twin screw machines for CFD analysis is widely used by the refrigeration and air-conditioning industry today, but is currently not suitable for topologies such as those of single screw, variable pitch or tri screw rotors. This paper investigates a technique called key-frame re-meshing that supplies pre-generated unstructured grids to the CFD solver at different time steps. To evaluate its accuracy, the results of an isentropic compression-expansion process in a r...

  2. The influence of implant-abutment connection on the screw loosening and microleakage.

    Science.gov (United States)

    Tsuruta, Katsuhiro; Ayukawa, Yasunori; Matsuzaki, Tatsuya; Kihara, Masafumi; Koyano, Kiyoshi

    2018-04-09

    There are some spaces between abutment and implant body which can be a reservoir of toxic substance, and they can penetrate into subgingival space from microgap at the implant-abutment interface. This penetration may cause periimplantitis which is known to be one of the most important factors associated with late failure. In the present study, three kinds of abutment connection system, external parallel connection (EP), internal parallel connection (IP), and internal conical connection (CC), were studied from the viewpoint of microleakage from the gap between the implant and the abutment and in connection with the loosening of abutment screw. We observed dye leakage from abutment screw hole to outside through microgap under the excessive compressive and tensile load and evaluated the anti-leakage characteristics of these connection systems. During the experiment, one abutment screw for EP and two screws for IP, out of seven samples in each group, were fractured. After the 2000 cycles of compressive tensile loadings, removal torque value (RTV) of abutment screw represented no statistical differences among three groups. Standard deviation was largest in the RTV of EP and smallest in that of CC. The results of microleakage of toluidine blue from implant-abutment connection indicated that microleakage generally increased as loading procedure progressed. The amount of microleakage was almost plateau at 2000 cycles in CC, but still increasing in other two groups. The value of microleakage greatly scattered in EP, but the deviation of that in CC is significantly smaller. At 500 cycles of loading, there were no significant differences in the amount of microleakage among the groups, but at 1000, 1500, and 2000 cycles of loading, the amount of microleakage in CC was significantly smaller than that in IP. Throughout the experiment, the amount of microleakage in EP was largest, but no statistical difference was indicated due to the high standard deviation. Within the

  3. Locking screw apparatus and method for underwater remote replacement

    International Nuclear Information System (INIS)

    Balog, L.J.

    1987-01-01

    A method is described for locking in place a screw which secures together first and second structures in the internal region of a nuclear reactor core. The first structure has a screw bore with a counterbore portion formed in an outer surface. The method comprises the steps of: forming a lateral recess in the counterbore portion and spaced from the outer surface, providing an elongated screw having an enlarged shoulder flange and an angular drive head with a lateral width substantially less than that of the counterbore portion, disposing the screw through the screw bore in threaded engagement with the second structure and with the shoulder rotatably seated in the counterbore portion. This provides a locking member having an angular opening and disposing it in the counterbore portion against the flange with the drive head received in the opening for engagement with the locking member to prevent rotation. This deforms a portion of the locking member into the recess for engagement to prevent movement of the locking member with respect to the first structure

  4. Tests for the dynamic behavior of insulation valve screws

    International Nuclear Information System (INIS)

    Tulke, K.D.; Stoppler, W.; Stern, G.

    1994-01-01

    Thermal tensile tests were performed at a temperature of 270 C, with two new original insulation valve conical screws M30-Tx92,5 mm (material: 21 CrMo V 5 7)and two prestrained ones during the event on 27.12.92. In order to assure the results obtained with regard to the dynamic load on the insulation valve during ''quick opening'', in addition tensile impact tests were performed at 270 C with six original insulation valve conical screws. Impact velocity reached 13,5 m/s at four screws and 6 m/s at two screws. Test conditions regarding collision damping and mass distribution were adapted, by means of parameter studies, to the situation of the insulation valve. During thermal tensile tests, strength and deformation values, such as stress at flow start, tensile strength, fracture prolongation and strain, necking at fracture as well as energy absorption up to maximum force and up to rupture, were determined. During tensile impact tests, deformation values, such as elongation, strain and necking, and energy absorption by the screw, were determined. (orig.) [de

  5. Performance study of a twin-screw expander used in a geothermal organic Rankine cycle power generator

    International Nuclear Information System (INIS)

    Tang, Hao; Wu, Huagen; Wang, Xiaolin; Xing, Ziwen

    2015-01-01

    The ORC (organic Rankine cycle) system is an effective technology to generate electricity from low temperature heat sources. The twin-screw expander is a key component that is commonly used in the small-to-medium capacity ORC system to convert thermal energy into work. In this paper, the performance of a twin-screw expander is theoretically and experimentally studied. A mathematical model is developed and subsequently validated using experimental data. The effect of several important factors including expander speed, suction pressure and inlet superheat on the expander performance is investigated. Results indicate that the expander speed and suction pressure have large influences on the expander performance, while the inlet superheat has relatively small effect. The isentropic efficiency of the expander decreases from 0.88 to 0.6 and the expander volumetric efficiency decreases from 0.88 to 0.7 as the expander rotational speed increases from 1250 to 6000 rpm. The results further show that the expander volumetric efficiency decreases from 0.91 to 0.85 as the expander suction pressure increases from 0.33 to 0.47 MPa. Furthermore, the energy conversion efficiency of the studied ORC system using the twin-screw expander is as high as 7.5% under the site conditions. - Highlights: • Performance of a twin-screw expander used in an ORC (organic Rankine cycle) system was studied. • A thermodynamic model was developed for this purpose and experimentally validated. • Effect of several key factors on the expander performance was investigated. • Suction pressure has a large influence on the expander performance. • Twin-screw expanders can be operated with a wide range of heat source temperatures.

  6. Correction Capability in the 3 Anatomic Planes of Different Pedicle Screw Designs in Scoliosis Instrumentation.

    Science.gov (United States)

    Wang, Xiaoyu; Aubin, Carl-Eric; Coleman, John; Rawlinson, Jeremy

    2017-05-01

    Computer simulations to compare the correction capabilities of different pedicle screws in adolescent idiopathic scoliosis (AIS) instrumentations. To compare the correction and resulting bone-screw forces associated with different pedicle screws in scoliosis instrumentations. Pedicle screw fixation is widely used in surgical instrumentation for spinal deformity treatment. Screw design, correction philosophies, and surgical techniques are constantly evolving to achieve better control of the vertebrae and correction of the spinal deformity. Yet, there remains a lack of biomechanical studies that quantify the effects and advantages of different screw designs in terms of correction kinematics. The correction capabilities of fixed-angle, multiaxial, uniaxial, and saddle axial screws were kinematically analyzed, simulated, and compared. These simulations were based on the screw patterns and correction techniques proposed by 2 experienced surgeons for 2 AIS cases. Additional instrumentations were assessed to compare the correction and resulting bone-screw forces associated with each type of screw. The fixed-angle, uniaxial and saddle axial screws had similar kinematic behavior and performed better than multiaxial screws in the coronal and transverse planes (8% and 30% greater simulated corrections, respectively). Uniaxial and multiaxial screws were less effective than fixed-angle and saddle axial screws in transmitting compression/distraction to the anterior spine because of their sagittal plane mobility between the screw head and shank. Only the saddle axial screws allow vertebra angle in the sagittal plane to be independently adjusted. Pedicle screws of different designs performed differently for deformity corrections or for compensating screw placement variations in different anatomic planes. For a given AIS case, screw types should be determined based on the particular instrumentation objectives, the deformity's stiffness and characteristics so as to make the best of

  7. Control rod drives

    International Nuclear Information System (INIS)

    Hayakawa, Hiroyasu; Kawamura, Atsuo.

    1979-01-01

    Purpose: To reduce pellet-clad mechanical interactions, as well as improve the fuel safety. Constitution: In the rod drive of a bwr type reactor, an electric motor operated upon intermittent input such as of pulse signals is connected to a control rod. A resolver for converting the rotational angle of the motor to electric signals is connected to the rotational shaft of the motor and the phase difference between the output signal from the resolver and a reference signal is adapted to detect by a comparator. Based on the detection result, the controller is actuated to control a motor for control rod drive so that fine control for the movement of the control rod is made possible. This can reduce the moving distance of the control rod, decrease the thermal stress applied to the control rod and decrease the pellet clad mechanical interaction failures due to thermal expansion between the cladding tube and the pellets caused by abrupt changes in the generated power. (Furukawa, Y.)

  8. The multi-interlock and check of logical system for 5 MW low power reactor automatic rod

    International Nuclear Information System (INIS)

    Li Guangjian; Zhao Zengqiao

    1992-01-01

    The safety and reliability of the logical system for 5 MW LPR automatic rod are improved, because of using multi-interlock and manual check on line. The design character and function of the logical system are introduced

  9. Preliminary design and manufacturing feasibility study for a machined Zircaloy triangular pitch fuel rod support system (grids) (AWBA development program)

    International Nuclear Information System (INIS)

    Horwood, W.A.

    1981-07-01

    General design features and manufacturing operations for a high precision machined Zircaloy fuel rod support grid intended for use in advanced light water prebreeder or breeder reactor designs are described. The grid system consists of a Zircaloy main body with fuel rod and guide tube cells machined using wire EDM, a separate AM-350 stainless steel insert spring which fits into a full length T-slot in each fuel rod cell, and a thin (0.025'' or 0.040'' thick) wire EDM machined Zircaloy coverplate laser welded to each side of the grid body to retain the insert springs. The fuel rods are placed in a triangular pitch array with a tight rod-to-rod spacing of 0.063 inch nominal. Two dimples are positioned at the mid-thickness of the grid (single level) with a 90 0 included angle. Data is provided on the effectiveness of the manufacturing operations chosen for grid machining and assembly

  10. The improvement of screw compressor performance using a newly developed rotor profile

    International Nuclear Information System (INIS)

    Kishi, Takayuki; Nishio, Toshio; Matsui, Akira; Ino, Nobumi

    1994-01-01

    An oil-compression phenomenon occurs at two portions of a conventional oil injected screw compressor that degrades the isothermal efficiency of the screw compressor. Hence a new screw rotor profile and lubricant have been developed in order to avoid the above oil-compression phenomena. Mycom and Fermi National Accelerator Laboratory have measured the performance of a new Mycom compound type screw compressor 2016C using the new profile rotors and the new lubricant. In the experiments, a 33% enhancement rate in the isothermal efficiency of the new screw compressor installed in Fermilab was achieved

  11. Control Rod Malfunction at the NRAD Reactor

    Energy Technology Data Exchange (ETDEWEB)

    Thomas L. Maddock

    2010-05-01

    The neutron Radiography Reactor (NRAD) is a training, research, and isotope (TRIGA) reactor located at the INL. The reactor is normally shut down by the insertion of three control rods that drop into the core when power is removed from electromagnets. During a routine shutdown, indicator lights on the console showed that one of the control rods was not inserted. It was initially thought that the indicator lights were in error because of a limit switch that was out of adjustment. Through further testing, it was determined that the control rod did not drop when the scram switch was initially pressed. The control rod anomaly led to a six month shutdown of the reactor and an in depth investigation of the reactor protective system. The investigation looked into: scram switch operation, console modifications, and control rod drive mechanisms. A number of latent issues were discovered and corrected during the investigation. The cause of the control rod malfunction was found to be a buildup of corrosion in the control rod drive mechanism. The investigation resulted in modifications to equipment, changes to both operation and maintenance procedures, and additional training. No reoccurrences of the problem have been observed since corrective actions were implemented.

  12. Prototypical Rod Consolidation Demonstration Project

    International Nuclear Information System (INIS)

    1993-05-01

    The objective of Phase 3 of the Prototypical Rod consolidation Demonstration Project (PRCDP) was to procure, fabricate, assemble, and test the Prototypical Rod consolidation System as described in the NUS Phase 2 Final Design Report. This effort required providing the materials, components, and fabricated parts which makes up all of the system equipment. In addition, it included the assembly, installation, and setup of this equipment at the Cold Test Facility. During the Phase 3 effort the system was tested on a component, subsystem, and system level. This volume 1, discusses the PRCDP Phase 3 Test Program that was conducted by the HALLIBURTON NUS Environmental Corporation under contract AC07-86ID12651 with the United States Department of Energy. This document, Volume 1, Book 9 discusses the following topics: Integrated System Normal Operations Test Results and Analysis Report; Integrated System Off-Normal Operations Test Results and Analysis Report; and Integrated System Maintenance Operations Test Results and Analysis Report

  13. Modeling The Effect Of Extruder Screw Speed On The Mechanical ...

    African Journals Online (AJOL)

    Modeling The Effect Of Extruder Screw Speed On The Mechanical Properties Of High Density Polyethylene Blown Film. ... Journal of Modeling, Design and Management of Engineering Systems ... Two sets of multiple linear regression models were developed to predict impact failure weight and tenacity respectively.

  14. Unconventional fixation Thoracolumbar fractures using round hole boneplates and transpedicular screws

    International Nuclear Information System (INIS)

    Behairy, Yaser M.

    2001-01-01

    In an attempt to contain the high cost of commercially available pediclescrew systems, several authors have used unconventional alternatives such aslocally made plates or dynamic compression plates (DCP) along with cancellousscrews for transpedicular fixation of the thoracolumbar spine. These plates,however, allow for a wide range of motion at the plate-screw interphase andthe construct does not provide stability in the sagittal plane. Round holebone plates, on the other hand, allow much less mobility at the plate-screwinterphase and the final construct offers better stability in the sagittalplane. Our objective was to determine the clinical, radiologic and functionalstatus of patients who underwent posterior fracture fixation using round holebone plates and cancellous screws and evaluate the construct's ability tomaintain reduction of the fracture. This was a postoperative follow-up ofpatients with fractures around the thoracolumbar junction fixed using roundhole bone plates and cancellous transpedicular screws. Round hole bone platesalong with 6.5 mm transpedicular cancellous screws were used for posteriorspinal instrumentation in neurologically intact patients with isolatedunstable fractures of the last thoracic or first lumbar vertebra. Seventeenpatients were included in this study. There mean follow-up was 10 months(range 5 to 12). All had evidence of fusion at a mean of 5 months (range 4 to7). No patients had breakage or loosening of the screws and none had breakageof the plate. The mean kyphosis angle at the fracture site was 34 degreepreoperatively, -4 degree in the immediate postoperative period, and 3 degreeon final follow-up radiographs. The percentage loss of anterior vertebralbody height was 51% in the immediate postoperative period and 16% on finalfollow-up radiographs. The use of round hole bone plates along with 6.5 mmcancellous screws inserted into the pedicles provides an angle-stableconstruct that allows for better stability in the sagittal plane

  15. Utilization of the MAT method to analyze the nucleate boiling boundary in rod bundles subchannels

    International Nuclear Information System (INIS)

    Pedron, M.Q.

    1983-01-01

    The digital program PANTERA-1P, a new version of the COBRA-IIIC code, developed at CDTN, is directed to the thermal-hydraulic analysis of water cooled rod bundles and reactor cores, insteady state and transient conditions. Both the new and the old code versions have identical capacities in what concerns evaluation of fluid variables, nevertheless PANTERA-1P has better and faster performance. Improvements introduced in the scheme for solution of the conservation equations have contributed significantly to reduce the computer time, without affecting the accuracy of results. While the momentum equations are solved in COBRA-IIIC for the crossflow distribution, the PANTERA-1P code solves these equations for the pressure distribution by using the MAT method (Modified and Advanced Theta). The calculation of the pressure coefficient matrix has been optimized and simultaneous linear equations are solved optionally by means of the transpose elimination with storage requirements or the successive over-relaxation methods. The program presents others features specially in what concerns the thermal conduction model for fuel rods and the critical heat flux calculations options. A new input/output scheme is provided for optional use of the British or Internacional System of Units. The results of the program are compared to the critical heat flux experimental data and to the results of COBRA-IIIC. Excellent agreement is observed in both cases. (Author) [pt

  16. Combined circular external fixation and open reduction internal fixation with pro-syndesmotic screws for repair of a diabetic ankle fracture

    Directory of Open Access Journals (Sweden)

    Zacharia Facaros

    2010-10-01

    Full Text Available The surgical management of ankle fractures among the diabetic population is associated with higher complication rates compared to the general population. Efforts toward development of better methods in prevention and treatment are continuously evolving for these injuries. The presence of peripheral neuropathy and the possible development of Charcot neuroarthropathy in this high risk patient population have stimulated much surgical interest to create more stable osseous constructs when open reduction of an ankle fracture/dislocation is required. The utilization of multiple syndesmotic screws (pro-syndesmotic screws to further stabilize the ankle mortise has been reported by many foot and ankle surgeons. In addition, transarticular Steinmann pins have been described as an adjunct to traditional open reduction with internal fixation (ORIF of the ankle to better stabilize the talus, thus minimizing risk of further displacement, malunion, and Charcot neuroarthropathy. The authors present a unique technique of ORIF with pro-syndesmotic screws and the application of a multi-plane circular external fixator for management of a neglected diabetic ankle fracture that prevented further deformity while allowing a weight-bearing status. This technique may be utilized for the management of complex diabetic ankle fractures that are prone to future complications and possible limb loss.

  17. Pullout strength of misplaced pedicle screws in the thoracic and lumbar vertebrae - A cadaveric study

    Directory of Open Access Journals (Sweden)

    Shyam K Saraf

    2013-01-01

    Full Text Available Background: The objective of this cadaveric study was to analyze the effects of iatrogenic pedicle perforations from screw misplacement on the mean pullout strength of lower thoracic and lumbar pedicle screws. We also investigated the effect of bone mineral density (BMD, diameter of pedicle screws, and the region of spine on the pullout strength of pedicle screws. Materials and Methods: Sixty fresh human cadaveric vertebrae (D10-L2 were harvested. Dual-energy X-ray absorptiometry (DEXA scan of vertebrae was done for BMD. Titanium pedicle screws of different diameters (5.2 and 6.2 mm were inserted in the thoracic and lumbar segments after dividing the specimens into three groups: a standard pedicle screw (no cortical perforation; b screw with medial cortical perforation; and c screw with lateral cortical perforation. Finally, pullout load of pedicle screws was recorded using INSTRON Universal Testing Machine. Results: Compared with standard placement, medially misplaced screws had 9.4% greater mean pullout strength and laterally misplaced screws had 47.3% lesser mean pullout strength. The pullout strength of the 6.2 mm pedicle screws was 33% greater than that of the 5.2 mm pedicle screws. The pullout load of pedicle screws in lumbar vertebra was 13.9% greater than that in the thoracic vertebra ( P = 0.105, but it was not statistically significant. There was no significant difference between pullout loads of vertebra with different BMD ( P = 0.901. Conclusion: The mean pullout strength was less with lateral misplaced pedicle screws while medial misplaced pedicle screw had more pullout strength. The pullout load of 6.2 mm screws was greater than that of 5.2 mm pedicle screws. No significant correlation was found between bone mineral densities and the pullout strength of vertebra. Similarly, the pullout load of screw placed in thoracic and lumbar vertebrae was not significantly different.

  18. Status of rod consolidation

    International Nuclear Information System (INIS)

    Bailey, W.J.

    1985-04-01

    Two of the factors that need to be taken into account with rod consolidation are (1) the effects on rods from their removal from the fuel assembly and (2) the effects on rods as a result of the consolidation process. Potential components of both factors are described in the report. Discussed under (1) are scratches on the fuel rod surfaces, rod breakage, crud, extended burnup, and possible cladding embrittlement due to hydrogen injection at BWRs. Discussed under (2) are the increased water temperature (less than 10 0 C) because of closer packing of the rods, formation of crevices between rods in the close-packed mode, contact with dissimilar metals, and the potential for rapid heating of fuel rods following the loss of water from a spent fuel storage pool. Another factor that plays an important role in rod consolidation is the cost of disposal of the nonfuel-bearing components of the fuel assembly. Also, the dose rate from the components - especially Inconel spacer grids - can affect the handling procedures. Several licensing issues that exist are described. A list of recommendations is provided. 98 refs., 5 figs., 5 tabs

  19. Intermaxillary Fixation Screw Morbidity in Treatment of Mandibular Fractures

    DEFF Research Database (Denmark)

    Florescu, Vlad-Andrei; Kofod, Thomas; Pinholt, Else Marie

    2016-01-01

    Purpose The aim of the present retrospective study was to investigate the morbidity of screws used for intermaxillary fixation (IMF) in the treatment of mandibular fractures. A review of the published data was also performed for a comparison of outcomes. Our hypothesis was that the use of screws...... for IMF of mandibular fractures would result in minimal morbidity. Materials and Methods Patients treated for mandibular fractures from 2007 to 2013, using screws for IMF, using the international diagnosis code for mandibular fracture, DS026, were anonymously selected (Department of Oral and Maxillofacial...... Surgery, Rigshospitalet, University Hospital of Copenhagen, Copenhagen, Denmark). The fracture type, radiographic findings, treatment modality, screw type and number, and root damage were recorded. For the outcome comparison, a review of the published data regarding iatrogenic dental root damage caused...

  20. The Analysis of Soil Resistance During Screw Displacement Pile Installation

    Science.gov (United States)

    Krasinski, Adam

    2015-02-01

    The application of screw displacement piles (SDP) is still increasing due to their high efficiency and many advantages. However, one technological problem is a serious disadvantage of those piles. It relates to the generation of very high soil resistance during screw auger penetration, especially when piles are installed in non-cohesive soils. In many situations this problem causes difficulties in creating piles of designed length and diameter. It is necessary to find a proper method for prediction of soil resistance during screw pile installation. The analysis of screw resistances based on model and field tests is presented in the paper. The investigations were carried out as part of research project, financed by the Polish Ministry of Science and Higher Education. As a result of tests and analyses the empirical method for prediction of rotation resistance (torque) during screw auger penetration in non-cohesive subsoil based on CPT is proposed.