WorldWideScience

Sample records for screening test kits

  1. An evaluation of chemical screening test kits for lead in paint

    Energy Technology Data Exchange (ETDEWEB)

    Oglesby, L.S.

    1996-04-01

    The Residential Lead-Based Paint Hazard Reduction Act (Title X) requires abatement and management of lead-based paint. The purpose of this study was to evaluate three chemical screening test kits using materials and methods from one study and subjecting the results to the statistical analysis of another. The three kits were used to predict the presence of lead in paint at ten weight concentrations from 0.04 to 3.97%. Paint was applied to four wood boards yielding a sample size of 40. Four boards were painted with lead-free paint and used as blanks. All of the boards were tested with the three test kits by an untrained individual having no knowledge of the actual lead content. Sensitivity, specificity, and false positive and negative rates were calculated for the test kit results. The manufactures` detection limits, the observed sensitivity ranged from 1.00 to 0.80, specificity ranged from 1.00 to 0.42, false positive ranged from 0 to 58%, and false negatives ranged from 0 to 20%. At the 0.5% Federal threshold level, the observed sensitivity ranged from 1.00 to 0.94, specificity ranged from 1.00 to 0.5, false positives ranged from 0 to 11.1%, and false negatives ranged from 0 to 20%. The observed false positive and false negative rates for all three kits were found to be significantly lower than those reported in a previous study. These results indicate that the kits perform very well at the Federal threshold, with two of the kits having false negative rates below 12.5% and false positive rates of 3.13%. These results indicate that these two kits would probably be acceptable screening tests for lead in paint.

  2. [Utilization of self-sampling kits for HPV testing in cervical cancer screening - pilot study].

    Science.gov (United States)

    Ondryášová, H; Koudeláková, V; Drábek, J; Vaněk, P; Slavkovský, R; Hajdúch, M

    2015-12-01

    To get initial experience with alternative sampling (self-sampling) for HPV testing as the means of cervical cancer screening program. Original work. Institute of Molecular and Translational Medicine, Faculty of Medicine and Dentistry, Palacky University in Olomouc. Based on expression of interest, 215 self-sampling kits were posted to women. Evalyn(®) Brush Vaginal swabs obtained by self-sampling were analyzed for the presence of HPV infection by Cobas 4800 HPV (Roche) followed by genotyping using PapilloCheck(®) HPV-Screening (Greiner Bio-One). Sixty women randomly chosen from our sample were sent a questionnaire focused on their experience with self-sampling. One hundred seventy-four of 215 (81%) distributed self-sampling devices have been delivered to analysis. All cervicovaginal swabs were sampled correctly and it was possible to analyze them by Cobas 4800 HPV test. Similarly, 98% (171/174) samples were analyzable by PapilloCheck(®) HPV-Screening.One hundred twenty-five (72%) of 174 tested samples were HPV negative. Low risk HPV infection was detected only in 7 samples (4%), and high risk HPV (hrHPV) infection was present in 42 samples (24%). The most frequently detected hrHPV genotypes were HPV16 (11/42; 26%) and HPV53 (6/42; 14%). HrHPV co-infection was detected in 10 cases, in 5 of them lrHPV infection was find also.Of the 60 questionnaires, 48 (80%) were returned. From this group, 47 (98%) women rated their experience with self-sampling device as good to excellent. User manual of self-sampling device was considered good to excellent by all women (100%). All women also rated the convenience of self-sampling device using as good to excellent. As expected, most of the women (n = 42 [88%]) preferred self-sampling to physician sampling. Cervicovaginal self-sampling leads to valid results of HPV screening using two molecular genetics methods and was accepted by Czech women very well. The self-sampling as an opportunity to participate in cervical cancer

  3. Comparative study of three screening tests, two microbiological tube tests, and a multi-sulphonamide ELISA kit for the detection of antimicrobial and sulphonamide residues in eggs.

    Science.gov (United States)

    Gaudin, V; Hedou, C; Rault, A; Sanders, P; Verdon, E

    2009-04-01

    The screening of antimicrobial residues in eggs is an especially important subject. Three different commercial kits for the screening of sulphonamides and other antimicrobials in eggs were validated in accordance with Decision 2002/657/EC: one enzyme-linked immunoabsorbant assay (ELISA) kit multi-sulphonamides (from RAISIO Diagnostics) and two microbiological tests (a Premi test from DSM and an Explorer kit from Zeu-Inmunotec). The false-positive rates were lower than 2% for all kits. The detection capabilities (CCbeta) have to be as low as possible for banned substances and lower than the maximum residue limit (MRL) when MRLs have been set. The sensitivity of the Premi test was better than that of the Explorer test, probably because of the dilution of the eggs before the Explorer test was used. The CCbeta values towards most of the tested sulphonamides were satisfactory with the Premi test (amoxicillin, neomycin, tylosin and erythromycin were lower than their respective MRLs. Detection capabilities for sulphonamides were much lower for the ELISA kit than for microbiological tests. The ELISA kit could be recommended for the targeted screening of sulphonamides in eggs. On the other hand, the Explorer and Premi tests could be used as wide screening tests allowing the detection of most of the antimicrobial families.

  4. Community-Based Colorectal Cancer Screening in a Rural Population: Who Returns Fecal Immunochemical Test (FIT) Kits?

    Science.gov (United States)

    Crosby, Richard A; Stradtman, Lindsay; Collins, Tom; Vanderpool, Robin

    2017-09-01

    To determine the return rate of community-delivered fecal immunochemical test (FIT) kits in a rural population and to identify significant predictors of returning kits. Residents were recruited in 8 rural Kentucky counties to enroll in the study and receive an FIT kit. Of 345 recruited, 82.0% returned an FIT kit from the point of distribution. These participants were compared to the remainder relative to age, sex, marital status, having an annual income below $15,000, not graduating from high school, not having a regular health care provider, not having health care coverage, being a current smoker, indicating current overweight or obese status, and a scale measure of fatalism pertaining to colorectal cancer. Predictors achieving significance at the bivariate level were entered into a stepwise logistic regression model to calculate adjusted OR and 95% CI. The return rate was 82.0%. In adjusted analyses, those indicating an annual income of less than $15,000 were 2.85 times more likely to return their kits (95% CI: 1.56-5.24; P < .001). Also, those not perceiving themselves to be overweight/obese were 1.95 times more likely to return their kits (95% CI: 1.07-3.55; P = .029). An outreach-based colorectal cancer screening program in a rural population may yield high return rates. People with annual incomes below $15,000 and those not having perceptions of being overweight/obese may be particularly likely to return FIT kits. © 2016 National Rural Health Association.

  5. Screening of antibiotics residues and development a new kit

    International Nuclear Information System (INIS)

    Elkhaoui, Faycel

    2009-01-01

    The first part of the work was to detect antibiotic residues in animal nutriment: chicken, fish, eggs and milk, by methods of screening: First Test and Delvotest. The second part covered the development of a new kit for the detection of antibiotics residues for honey and competitor kit First Test and saving time and money.

  6. Screening and Monitoring Coeliac Disease: Multicentre Trial of a New Serum Antibody Test Kit

    Directory of Open Access Journals (Sweden)

    Peter L. Devine

    1994-01-01

    average interassay CV was 6.4% for IgA and 4.3% for IgG (n=3. By defining a positive te st as both IgA and IgG elevated, a sensitivity of 93% in untreated coeliacs (n=75 was observed. The corresponding specificities in healthy adults (n=130 and healthy children (n=77 were >99% and 100% respectively, while in patients with other gastrointestinal disorders (disease controls the specificity was 94% (n=129. The test was also useful in monitoring patients, with anti-gliadin IgA and IgG falling for up to a year after commencing a gluten-free diet (GFD (12 adults. In some patients however, antibody levels did not reach the normal cutpoint after many months on a GFD, which may reflect the patients ' poor adherence to their gluten free diet. The test was superior to the Pharmacia anti-gliadin ELISA, and should be useful as an aid to the diagnosis of coeliac disease, as well as in the follow-up of treated patients.

  7. FUELS IN SOIL TEST KIT: FIELD USE OF DIESEL DOG SOIL TEST KITS

    Energy Technology Data Exchange (ETDEWEB)

    Unknown

    2001-05-31

    Western Research Institute (WRI) is commercializing Diesel Dog Portable Soil Test Kits for performing analysis of fuel-contaminated soils in the field. The technology consists of a method developed by WRI (U.S. Patents 5,561,065 and 5,976,883) and hardware developed by WRI that allows the method to be performed in the field (patent pending). The method is very simple and does not require the use of highly toxic reagents. The aromatic components in a soil extract are measured by absorption at 254 nm with a field-portable photometer. WRI added significant value to the technology by taking the method through the American Society for Testing and Materials (ASTM) approval and validation processes. The method is designated ASTM Method D-5831-96, Standard Test Method for Screening Fuels in Soils. This ASTM designation allows the method to be used for federal compliance activities. In FY 99, twenty-five preproduction kits were successfully constructed in cooperation with CF Electronics, Inc., of Laramie, Wyoming. The kit components work well and the kits are fully operational. In the calendar year 2000, kits were provided to the following entities who agreed to participate as FY 99 and FY 00 JSR (Jointly Sponsored Research) cosponsors and use the kits as opportunities arose for field site work: Wyoming Department of Environmental Quality (DEQ) (3 units), F.E. Warren Air Force Base, Gradient Corporation, The Johnson Company (2 units), IT Corporation (2 units), TRC Environmental Corporation, Stone Environmental, ENSR, Action Environmental, Laco Associates, Barenco, Brown and Caldwell, Dames and Moore Lebron LLP, Phillips Petroleum, GeoSyntek, and the State of New Mexico. By early 2001, ten kits had been returned to WRI following the six-month evaluation period. On return, the components of all ten kits were fully functional. The kits were upgraded with circuit modifications, new polyethylene foam inserts, and updated instruction manuals.

  8. [The comparison of two newborn cytomegalovirus IgG antibody screening ELISA kits].

    Science.gov (United States)

    Zhang, Shun-Xian; He, Xiao-Zhou; Wang, Shi-Wen; Wang, Xiao-Fang

    2013-10-01

    This study compared two newborn Cytomegalovirus (CMV) IgG antibody screening ELISA kits and evaluated the detection effectiveness of Abnova kit. CMV IgG antibodies were detected by both SeraQuest and Abnova kits from dried blood spot (DBS) samples of 488 newborn heel sticks. The detection abilities of these two kits were compared in different sample dilution concentrations. Relative detection effectiveness of the Abnova kit was defined by statistical method using the SeraQuest kit as a point of comparison. Compared to the SeraQuest screening test kit, the Abnova kit revealed a sensitivity of 98.9%, specificity of 78.6%, positive predictive value of 99.3%, negative predictive value of 68.8%, and the coincidence rate for these two screening test kits at 98.3%. The consistency check of both kits based on interpretation of the kappa statistic was relatively good. For the Abnova kit, the "area under the ROC curve" was 0.887, which indicates moderate accuracy. Abnova kit can be applied to newborn screening for congenital CMV infections. However, repeating the test for ambiguous results is suggested to increase the specificity and negative predictive value.

  9. Factors associated with use and non-use of the Fecal Immunochemical Test (FIT) kit for Colorectal Cancer Screening in Response to a 2012 outreach screening program: a survey study.

    Science.gov (United States)

    Gordon, Nancy P; Green, Beverly B

    2015-06-11

    The one-sample fecal immunochemical test (FIT) is gaining popularity for colorectal cancer (CRC) screening of average-risk people. However, uptake and annual use remain suboptimal. In 2013, we mailed questionnaires to three groups of nonHispanic White, Black, and Latino Kaiser Permanente Northern California (KPNC) members ages 52-76 who received FIT kits in 2010-2012: Continuers did the FIT all 3 years; Converts in 2012, but not 2010 or 2011; and Nonusers in none of the 3 years. The questionnaires covered social influences, perceived CRC risk, reasons for using (Continuers, Converts) or avoiding using (Nonusers) the FIT, and recommendations for improving the kit. Continuers (n = 607, response rate 67.5%), Converts (n = 317, response rate 35.6%), and Nonusers (n = 215, response rate 21.1%) did not differ in perceived risk or family history of CRC, but Nonusers were less likely than Continuers and Converts to know someone who had polyps or CRC. Continuers, Converts, and Nonusers did not differ in social network encouragement of CRC screening, but did differ in believing that it was very important that they be screened (88.3%, 68.4%, 47.7%) and that their medical team thought it very important that they be screened (88.6%, 79.9%, 53.9%). Approximately half of Continuers and Converts completed the FIT to please their doctor. Converts were less likely than Continuers to use the FIT to "make sure they were OK" (53.7% vs. 72.6%) or "protect their health" (46.1% vs. 76.4%). Nearly half of Converts completed the FIT out of guilt. Approximately half of FIT kit users suggested adding a disposable glove, extra paper, and wider-mouth tube to the kit. Nonusers' reasons for not using the FIT included discomfort, disgust, or embarrassment (59.6%); thinking it unnecessary (32.9%); fatalism/fear (15.5%); and thinking it too difficult to use (14.5%), but screening at all. Nonusers and irregular users of the FIT are less intrinsically motivated to get CRC screening than

  10. Pharmacists' views on and experiences with bowel cancer screening kits in Auckland, New Zealand.

    Science.gov (United States)

    Martini, Nataly; Basdew, Kamlika; Kammona, Ala; Shen, Amy; Taylor, Caragh; McIntosh, Timothy R; Barnes, Joanne

    2014-08-01

    To explore the views of New Zealand pharmacists on bowel cancer screening, particularly with regards to faecal occult blood testing (FOBT) kits, self-perceived knowledge on FOBT kits and barriers, motivators and experiences with selling and counselling consumers with respect to FOBT kits. Semi-structured interviews were conducted face to face or by telephone with 20 community pharmacists in the Auckland region. Interviews were recorded and transcribed verbatim and data were coded and analysed using NVivo software to identify key themes. Participant pharmacists believed that they were well placed to provide advice on FOBT kits to consumers. Barriers to selling the kits included cost and perceived lack of test sensitivity of the kits, poor consumer demand, pharmacists' lack of training and information, and a belief that selling FOBT kits was outside the pharmacists' scope of practice. Motivators to selling the kits included customer convenience, ease of use, confidence in the kits and embracing new roles for pharmacists. Pharmacists were concerned that use of the kits may increase the burden on the public health system through customer anxiety over test results; however, they agreed that there was a need for bowel cancer screening and awareness and that people concerned about bowel cancer should make visiting their general practitioner a priority. Pharmacists' views were mixed. Pharmacists' training and competence with respect to the provision of bowel cancer kits, and how a bowel cancer screening service can be developed to optimise public health outcomes, need to be addressed. © 2013 Royal Pharmaceutical Society.

  11. FUELS IN SOIL TEST KIT: FIELD USE OF DIESEL DOG SOIL TEST KITS

    Energy Technology Data Exchange (ETDEWEB)

    Susan S. Sorini; John F. Schabron; Joseph F. Rovani, Jr.

    2002-09-30

    Western Research Institute (WRI) has developed a new commercial product ready for technology transfer, the Diesel Dog{reg_sign} Portable Soil Test Kit, for performing analysis of fuel-contaminated soils in the field. The technology consists of a method developed by WRI (U.S. Patents 5,561,065 and 5,976,883) and hardware developed by WRI that allows the method to be performed in the field (patent pending). The method is very simple and does not require the use of highly toxic reagents. The aromatic components in a soil extract are measured by absorption at 254 nm with a field-portable photometer. WRI added significant value to the technology by taking the method through the American Society for Testing and Materials (ASTM) approval and validation processes. The method is designated as ASTM Method D 5831-96, Standard Test Method for Screening Fuels in Soils. This ASTM designation allows the method to be used for federal compliance activities. In June 2001, the Diesel Dog technology won an American Chemical Society Regional Industrial Innovations Award. To gain field experience with the new technology, Diesel Dog kits have been used for a variety of site evaluation and cleanup activities. Information gained from these activities has led to improvements in hardware configurations and additional insight into correlating Diesel Dog results with results from laboratory methods. The Wyoming Department of Environmental Quality (DEQ) used Diesel Dog Soil Test Kits to guide cleanups at a variety of sites throughout the state. ENSR, of Acton, Massachusetts, used a Diesel Dog Portable Soil Test Kit to evaluate sites in the Virgin Islands and Georgia. ChemTrack and the U.S. Army Corps of Engineers successfully used a test kit to guide excavation at an abandoned FAA fuel-contaminated site near Fairbanks, Alaska. Barenco, Inc. is using a Diesel Dog Portable Soil Test Kit for site evaluations in Canada. A small spill of diesel fuel was cleaned up in Laramie, Wyoming using a Diesel

  12. Experience with Phadebas hCS (HPL)-Test kit

    International Nuclear Information System (INIS)

    Herter, U.

    1976-01-01

    The RIA determination of human placental lactogen (HPL) is described using the Phadebas test kit by Pharmacia, Sweden. The results of the test are shown graphically. The kit was tested over a period of one year and the tests were modified to meet the requirements of clinical examinations. The calibration curve is constant and applicable for a period of 14 days. The Phadebas kit has proved to be advantageous for both scientific research work and for routine clinical examinations. (L.O.)

  13. Statistical modeling of dental unit water bacterial test kit performance.

    Science.gov (United States)

    Cohen, Mark E; Harte, Jennifer A; Stone, Mark E; O'Connor, Karen H; Coen, Michael L; Cullum, Malford E

    2007-01-01

    While it is important to monitor dental water quality, it is unclear whether in-office test kits provide bacterial counts comparable to the gold standard method (R2A). Studies were conducted on specimens with known bacterial concentrations, and from dental units, to evaluate test kit accuracy across a range of bacterial types and loads. Colony forming units (CFU) were counted for samples from each source, using R2A and two types of test kits, and conformity to Poisson distribution expectations was evaluated. Poisson regression was used to test for effects of source and device, and to estimate rate ratios for kits relative to R2A. For all devices, distributions were Poisson for low CFU/mL when only beige-pigmented bacteria were considered. For higher counts, R2A remained Poisson, but kits exhibited over-dispersion. Both kits undercounted relative to R2A, but the degree of undercounting was reasonably stable. Kits did not grow pink-pigmented bacteria from dental-unit water identified as Methylobacterium rhodesianum. Only one of the test kits provided results with adequate reliability at higher bacterial concentrations. Undercount bias could be estimated for this device and used to adjust test kit results. Insensitivity to methylobacteria spp. is problematic.

  14. Innovative accountability of tracking test kit as locked resources: a lesson in a restricted resource setting.

    Science.gov (United States)

    Makuwani, Ahmad M; Msuya, Sia; Haule, Dunstan; Mogella, Deus; Nkya, Efesper

    2013-09-01

    To implement quality screening in a blood service requires the presence of screening strategy with a clear algorithm and supporting standard operating procedures (SOPs), skilled and motivated human resource to perform testing, infrastructure, regular available test kits, and other supplies. In developing countries, smooth supply chain management of critical transfusion transmissible infections (TTIs) screening reagents is a challenge. Therefore, managing the little available kits by knowing the rate of consumption, good forecasting, and monitoring expiry date may be a key in ensuring regular supply. Test kit monitoring tool (TKMT) for Vironostika HIV Uni-Form kit/192 1&2 Ag/Ab, Genedia kits for HBsAg and HCV, and RPR for syphilis was developed to track these reagents. This excel tool was developed to assess received reagents, quantity used, quantity remaining, and date of expiration. The tool was evaluated by assessing rerun for each test kits, match tests conducted with blood units tested, adherence to the principle of first in-first out (FIFO), and quantity remaining in the center against the need. The mean rerun for HIV ELISA Vironistika uniform II Ag/Ab observed over expected was 6.9% (n = 3.8) than 2.4% (n = 1.3), HBsAg was 9.9% (n = 5.7) than 6.7% (3.5) (expected), Genedia for HCV was 1.3% (n = 0.7) than 0.5% (n = 0.3), and RPR test for syphilis 3.3% (n = 1.5) than 0.5%. During implementation, TKMT managed to detect expiring kits in the zonal blood transfusion centers. A tool-like TKMT may capture other supplies within blood when expanded. Monitoring of supplies may enable blood service actual accounting and in forecasting supplies and reagents. © 2013 Wiley Periodicals, Inc.

  15. Evaluation of Desensol As a Standard Patch Test Kit

    Directory of Open Access Journals (Sweden)

    K C Shah

    1987-01-01

    Full Text Available In a study undertaken to find out the usefulness of ′Desensol′ patch test kit to detect contact allergens, in 200 cases revealed 24 cases with negative patch test with all the antigens and 55 cases reacted to even the Vaseline control. -Excluding these 79 cases, the common contact allergens were potassium bichr6ma,te, (40.49%, TMTD(28.92%, PPD(24.79%, epoxy resin (23.14%, colophony (19.0%, nickel sulfate (19.0%, Framycetin (19.0% and nitrofurazone (19.0%. Desensol patch test kit is lacking in certain antigens while in our country due to varied environmental factors and social customs, a person is exposed to a large number of natural and man-made contact allergens. So usefulness of such a kit like. Desensol is limited.

  16. Field Test Kit for Gun Residue Detection; TOPICAL

    International Nuclear Information System (INIS)

    WALKER, PAMELA K.; RODACY, PHILIP J.

    2002-01-01

    One of the major needs of the law enforcement field is a product that quickly, accurately, and inexpensively identifies whether a person has recently fired a gun--even if the suspect has attempted to wash the traces of gunpowder off. The Field Test Kit for Gunshot Residue Identification based on Sandia National Laboratories technology works with a wide variety of handguns and other weaponry using gunpowder. There are several organic chemicals in small arms propellants such as nitrocellulose, nitroglycerine, dinitrotoluene, and nitrites left behind after the firing of a gun that result from the incomplete combustion of the gunpowder. Sandia has developed a colorimetric shooter identification kit for in situ detection of gunshot residue (GSR) from a suspect. The test kit is the first of its kind and is small, inexpensive, and easily transported by individual law enforcement personnel requiring minimal training for effective use. It will provide immediate information identifying gunshot residue

  17. Determination of total galactose from dried blood spots—extensive assay evaluation of a CE-marked test-kit

    OpenAIRE

    Fingerhut, R; Torresani, T

    2013-01-01

    Most newborn screening laboratories use CE-marked or FDA-approved test-kits, like in routine clinical chemistry. National regulations require only minimal evaluation from the customer, if the test-kits are used as specified by the manufacturer. The microtiter-based kit-concept is often based on the perception, that the laboratory always processes whole microtiter plates. However, in the daily routine, this is rather a rare exception, which leads to much higher costs per newborn, compared to t...

  18. Fabrication of CANFLEX bundle kit for irradiation test in NRU

    International Nuclear Information System (INIS)

    Cho, Moon Sung; Kwon, Hyuk Il; Ji, Chul Goo; Chang, Ho Il; Sim, Ki Seob; Suk, Ho Chun.

    1997-10-01

    CANFLEX bundle kit was prepared at KAERI for the fabrication of complete bundle at AECL. Completed bundle will be used for irradiation test in NRU. Provisions in the 'Quality Assurance Manual for HWR Fuel Projects,' 'Manufacturing Plan' and 'Quality Verification, Inspection and Test Plan' were implemented as appropriately for the preparation of CANFLEX kit. A set of CANFLEX kit consist of 43 fuel sheath of two different sizes with spacers, bearing pads and buttons attached, 2 pieces of end plates and 86 pieces of end caps with two different sizes. All the documents utilized as references for the fabrication such as drawings, specifications, operating instructions, QC instructions and supplier's certificates are specified in this report. Especially, suppliers' certificates and inspection reports for the purchased material as well as KAERI's inspection report are integrated as attachments to this report. Attached to this report are supplier's certificates and KAERI inspection reports for the procured materials and KAERI QC inspection reports for tubes, pads, spacers, buttons, end caps, end plates and fuel sheath. (author). 37 refs

  19. Development of a qualitative, multiplex real-time PCR kit for screening of genetically modified organisms (GMOs).

    Science.gov (United States)

    Dörries, Hans-Henno; Remus, Ivonne; Grönewald, Astrid; Grönewald, Cordt; Berghof-Jäger, Kornelia

    2010-03-01

    The number of commercially available genetically modified organisms (GMOs) and therefore the diversity of possible target sequences for molecular detection techniques are constantly increasing. As a result, GMO laboratories and the food production industry currently are forced to apply many different methods to reliably test raw material and complex processed food products. Screening methods have become more and more relevant to minimize the analytical effort and to make a preselection for further analysis (e.g., specific identification or quantification of the GMO). A multiplex real-time PCR kit was developed to detect the 35S promoter of the cauliflower mosaic virus, the terminator of the nopaline synthase gene of Agrobacterium tumefaciens, the 35S promoter from the figwort mosaic virus, and the bar gene of the soil bacterium Streptomyces hygroscopicus as the most widely used sequences in GMOs. The kit contains a second assay for the detection of plant-derived DNA to control the quality of the often processed and refined sample material. Additionally, the plant-specific assay comprises a homologous internal amplification control for inhibition control. The determined limits of detection for the five assays were 10 target copies/reaction. No amplification products were observed with DNAs of 26 bacterial species, 25 yeasts, 13 molds, and 41 not genetically modified plants. The specificity of the assays was further demonstrated to be 100% by the specific amplification of DNA derived from reference material from 22 genetically modified crops. The applicability of the kit in routine laboratory use was verified by testing of 50 spiked and unspiked food products. The herein described kit represents a simple and sensitive GMO screening method for the reliable detection of multiple GMO-specific target sequences in a multiplex real-time PCR reaction.

  20. AN ENVIRONMENTAL TECHNOLOGY VERIFICATION (ETV) PERFORMANCE TESTING OF THE INDUSTRIAL TEST SYSTEM, INC. CYANIDE REAGENTSTRIP™ TEST KIT

    Science.gov (United States)

    Cyanide can be present in various forms in water. The cyanide test kit evaluated in this verification study (Industrial Test System, Inc. Cyanide Regent Strip ™ Test Kit) was designed to detect free cyanide in water. This is done by converting cyanide in water to cyanogen...

  1. Glucose screening tests during pregnancy

    Science.gov (United States)

    Oral glucose tolerance test - pregnancy; OGTT - pregnancy; Glucose challenge test - pregnancy; Gestational diabetes - glucose screening ... screening test between 24 and 28 weeks of pregnancy. The test may be done earlier if you ...

  2. Neonatal cystic fibrosis screening test

    Science.gov (United States)

    Cystic fibrosis screening - neonatal; Immunoreactive trypsinogen; IRT test; CF - screening ... Cystic fibrosis is a disease passed down through families. CF causes thick, sticky mucus to build up in ...

  3. A comparative study of faecal occult blood kits in a colorectal cancer screening program in a cohort of healthy construction workers.

    LENUS (Irish Health Repository)

    Shuhaibar, M

    2012-02-01

    BACKGROUND: The incidence of colorectal cancer (CRC) has been increasing. We evaluated uptake rates and outcomes of faecal immunochemical test (FIT) and Guaiac test (gFOBT) kits as part of a two-step CRC screening. METHODS: A 3-year CRC screening program for a defined population of construction workers was conducted. Those satisfying the inclusion criteria were provided with gFOBT or FIT kits. Individuals testing positive were invited for a colonoscopy. RESULTS: A total of 909 faecal testing kits were distributed. Age range was 53-60 years. Compliance rate was higher for FIT (58.3%) as compared to gFOBT (46.7%) (p = 0.0006). FIT detected adenomatous polyps and CRC in 37.5 and 25%, respectively, whereas; gFOBT detected 23.5 and 18%. Colonoscopies were normal in 53 and 25% tested positive by gFOBT and FIT, respectively (p = 0.016). CONCLUSION: The FIT was more cost-effective when compared with gFOBT with higher return rate, sensitivity and specificity. A comparative study of faecal occult blood kits in a CRC screening program in a healthy cohort of construction workers.

  4. Evaluation of a rapid immunodiagnostic test kit for rabies virus.

    Science.gov (United States)

    Kang, BoKyu; Oh, JinSik; Lee, ChulSeung; Park, Bong-Kyun; Park, YoungNam; Hong, KyungSoo; Lee, KyungGi; Cho, ByungKi; Song, DaeSub

    2007-10-01

    A rapid immunodiagnostic test kit for rabies virus detection was evaluated using 51 clinical samples and 4 isolates of rabies virus. The quick detection of rabies virus under field conditions may be helpful in determining if post-exposure prophylaxis is needed, thereby avoiding unnecessary treatments, as well as undue economic burden. There are several widely used diagnostic methods for rabies, including fluorescent antibody tests, reverse transcription polymerase chain reaction, and electron microscopy; however, these methods include time-consuming, intricate, and costly procedures. The rapid immunodiagnostic test was able to detect rabies virus in clinical samples, including brain tissue and saliva, in addition to 10(3.2) 50% lethal dose (LD(50))/mL cell-adapted rabies virus. The assay was not cross-reactive with non-rabies virus microbes. When the performance of the rapid immunodiagnostic test was compared to a fluorescent antibody test, the rapid immunodiagnostic test had a sensitivity of 91.7% and specificity of 100% (95.8% CI).

  5. Validity of a New Kit Measuring Salivary Lactate Dehydrogenase Level for Screening Gingivitis.

    Science.gov (United States)

    Ekuni, Daisuke; Yamane-Takeuchi, Mayu; Kataoka, Kota; Yokoi, Aya; Taniguchi-Tabata, Ayano; Mizuno, Hirofumi; Miyai, Hisataka; Uchida, Yoko; Fukuhara, Daiki; Sugiura, Yoshio; Tomofuji, Takaaki; Morita, Manabu

    2017-01-01

    Aim . The aim of this study was to determine the usefulness of a new kit that can evaluate salivary lactate dehydrogenase (LD) level in real time for screening gingivitis. Materials and Methods . The study included 70 systemic healthy volunteers [29 males and 41 females; mean age ± SD: 24.1 ± 2.6 years]. Resting saliva was collected from each participant and LD level was evaluated in real time using the kit (a color-changing sheet with an integer scale ranging from 1 to 10). A dentist measured probing pocket depth, clinical attachment level, and the proportion of sites with bleeding on probing (% BOP) at six sites on all teeth. Gingivitis was diagnosed when the BOP value was ≥20%. Results . Salivary LD level was positively correlated with mean % BOP (odds ratio: 1.47, 95% confidence interval: 1.132-1.916, and P gingivitis in young adults, which contributes to early detection of future periodontitis.

  6. Evaluation of field test kits including immunoassays for the detection of contaminants in soil and water

    International Nuclear Information System (INIS)

    Waters, L.C.; Smith, R.R.; Counts, R.W.; Stewart, J.H.; Jenkins, R.A.

    1993-01-01

    Effective field test methods are needed for hazardous waste site characterization and remediation. Useful field methods should be rapid, analyte-specific, cost-effective and accurate in the concentration range at which the analyte is regulated. In this study, field test kits for polychlorinated biphenyls (PCBs), mercury, lead and nitrate were evaluated with reference to these criteria. PCBs and mercury, in soils, were analyzed by immunoassay. Ionic lead and nitrate, in water, were measured chemically using test strips. Except for lead, each analyte was measured in both spiked and actual field samples. Twenty to 40 samples per day can be analyzed with the immunoassays and even more with the strip tests. The sensitivity of the immunoassays is in the 1-3 ppM range. Nitrate was consistently detected at ≥5 ppM; lead ions at ≥20 ppM. Results obtained using these methods compared favorably with those obtained by standard laboratory methods. In addition to being useful field screening methods, these kits can be used in the laboratory to sort out negative samples and/or to define proper dilutions for positive samples requiring further analysis

  7. Research Note The reliability of a field test kit for the detection and ...

    African Journals Online (AJOL)

    Research Note The reliability of a field test kit for the detection and the persistence of ... Open Access DOWNLOAD FULL TEXT ... The objectives were to test a field kit for practicality and reliability, to assess the spread of the bacteria among ...

  8. Tailgate test kit for determining appropriate sediment reducing chemicals and dose rates : final report.

    Science.gov (United States)

    2017-07-01

    This study develops a Tailgate Test Kit to be used in the field to test flocculants for reducing turbidity in construction stormwater discharge. Turbidity of stormwater runoff at construction sites varies depending on which site soils are exposed to ...

  9. AN ENVIRONMENTAL TECHNOLOGY VERIFICATION (ETV) TESTING OF THREE IMMUNOASSAY TEST KITS FOR ANTHRAX, BOTULINUM TOXIN AND RICIN

    Science.gov (United States)

    Immunoassay test kits are based on immunoassay methods, where specific antibodies are used to detect and measure the contaminants of interest. Immunoassay test kits rely on the reaction of a contaminant or antigen with a selective antibody to give a product that can be measures....

  10. Abnormal Cervical Cancer Screening Test Results

    Science.gov (United States)

    ... AQ FREQUENTLY ASKED QUESTIONS FAQ187 GYNECOLOGIC PROBLEMS Abnormal Cervical Cancer Screening Test Results • What is cervical cancer screening? • What causes abnormal cervical cancer screening test ...

  11. Development and testing of monoclonal antibody-based rapid immunodiagnostic test kits for direct detection of Vibrio cholerae O139 synonym Bengal.

    Science.gov (United States)

    Hasan, J A; Huq, A; Nair, G B; Garg, S; Mukhopadhyay, A K; Loomis, L; Bernstein, D; Colwell, R R

    1995-11-01

    We report on the development and testing of two monoclonal antibody-based rapid immunodiagnostic test kits, BengalScreen, a coagglutination test, and Bengal DFA, a direct fluorescent-antibody test, for direct detection of Vibrio cholerae O139 synonym Bengal in clinical and environmental specimens. The BengalScreen test requires less than 5 min to complete and can be used in the field. Bengal DFA, being more sensitive than BengalScreen, requires only one reagent and less than 20 min for detection and enumeration of V. cholerae O139 synonym Bengal. In tests for specificity, all 40 strains of V. cholerae O139 reacted with both test kits, whereas 157 strains of heterologous species examined did not, yielding 100% specificity in this study. A field trial was conducted in with both BengalScreen and Bengal DFA, and the results were compared with those obtained by conventional culture methods. BengalScreen demonstrated a sensitivity of 95%, a specificity of 100%, a positive predictive value of 100%, and a negative predictive value of 94%. Results obtained by Bengal DFA, on the other hand, were 100% sensitive and 100% specific and yielded 100% positive and negative predictive values compared with culture methods. In a second evaluation, 93 stool specimens from Mexico that were negative for V. cholerae O139 by culture were also tested with both the BengalScreen and Bengal DFA kits. None of the 93 specimens were positive for V. cholerae O139 by both tests. A concentration method was optimized for screening of environmental water samples for V. cholerae O139 synonym Bengal with rapid test kits. BengalScreen results were unequivocally positive when water samples contained at least 2.0 x 10(3) CFU/ml, whereas Bengal DFA demonstrated an unequivocally positive reaction when the water sample contained at least 1.5 x 10(2) CFU/ml. When Bengal DFA was compared with conventional culture methods for enumeration of V. cholerae O139 synonym Bengal organisms, no difference was observed.

  12. Evaluation of a clinic-based cholinesterase test kit for the Washington State Cholinesterase Monitoring Program.

    Science.gov (United States)

    Hofmann, Jonathan N; Carden, Angela; Fenske, Richard A; Ruark, Harold E; Keifer, Matthew C

    2008-07-01

    The Washington State Cholinesterase Monitoring Program for pesticide handlers requires blood draws at local clinics, with samples tested at a central laboratory. At present, workers with inhibited cholinesterase activity may be re-exposed before they can be removed from work. In this study we explored the option of on-site testing at local clinics using the EQM Test-mate Kittrade mark, a portable cholinesterase test kit. Test kit cholinesterase activity measurements were performed on 50 blood samples by our research staff, and compared to measurements on the same samples by the Washington State Public Health Laboratory. Another set of samples was also analyzed with the test kit by medical staff at an eastern Washington clinic. Triplicate measurements with the test kit had a 3.3% average coefficient of variation (CV) for plasma cholinesterase (PChE), and a 3.5% average CV for erythrocyte cholinesterase (AChE) measurements. The kit's PChE measurements were similar to PHL measurements (average ratio of 0.98) when performed in the laboratory, but had a tendency to underestimate activity when used in the clinic setting (average ratio of 0.87). The kit systematically overestimated AChE activity by 42-48% relative to the PHL measurements, regardless of where the samples were analyzed. This easy-to-use test kit appeared to be a viable method for clinic-based PChE measurements, but was less consistent for AChE measurements performed in the clinic. Absolute measurements with the kit need to be evaluated carefully relative to standardized methods. (c) 2008 Wiley-Liss, Inc.

  13. Monitoring acetylcholinesterase levels in migrant agricultural workers and their children using a portable test kit.

    Science.gov (United States)

    Higgins, G M; Muñiz, J F; McCauley, L A

    2001-02-01

    The EQM Research, Inc., portable test kit was evaluated as a surveillance tool for blood cholinesterase levels among migrant workers and their children. Laboratory validation demonstrated a linear relationship between the reference Ellman and kit methods (Ellman = 0.95 x kit result + 0.82, r2 = 0.98). Pre- and post-season cholinesterase levels measured in 70 farm workers were within normal ranges, but significantly different at 28.5 and 29.7 U/g Hb, respectively (paired t-test, p = 0.014). Results from 98 migrant farm worker children and a comparison group of 53 age-matched non-agricultural children showed that cholinesterase levels were not significantly different between the agricultural and non-agricultural children (ANOVA, p = 0.69). These data demonstrate that a portable test kit can provide useful data pesticide exposures when measurements are made in a temperature-controlled setting.

  14. Electronic vending machines for dispensing rapid HIV self-testing kits: a case study.

    Science.gov (United States)

    Young, Sean D; Klausner, Jeffrey; Fynn, Risa; Bolan, Robert

    2014-02-01

    This short report evaluates the feasibility of using electronic vending machines for dispensing oral, fluid, rapid HIV self-testing kits in Los Angeles County. Feasibility criteria that needed to be addressed were defined as: (1) ability to find a manufacturer who would allow dispensing of HIV testing kits and could fit them to the dimensions of a vending machine, (2) ability to identify and address potential initial obstacles, trade-offs in choosing a machine location, and (3) ability to gain community approval for implementing this approach in a community setting. To address these issues, we contracted a vending machine company who could supply a customized, Internet-enabled machine that could dispense HIV kits and partnered with a local health center available to host the machine onsite and provide counseling to participants, if needed. Vending machines appear to be feasible technologies that can be used to distribute HIV testing kits.

  15. Evaluation of rapid HIV test kits on whole blood and development of rapid testing algorithm for voluntary testing and counseling centers in Ethiopia.

    Science.gov (United States)

    Tegbaru, Belete; Messele, Tsehaynesh; Wolday, Dawit; Meles, PhD Hailu; Tesema, Desalegn; Birhanu, Hiwot; Tesfaye, Girma; Bond, Kyle B; Martin, Robert; Rayfield, Mark A; Wuhib, Tadesse; Fekadu, Makonnen

    2004-10-01

    Five simple and rapid HIV antibody detection assays viz. Determine, Capillus, Oraquick, Unigold and Hemastrip were evaluated to examine their performance and to develop an alternative rapid test based testing algorithm for voluntary counseling and testing (VCT) in Ethiopia. All the kits were tested on whole blood, plasma and serum. The evaluation had three phases: Primary lab review, piloting at point of service and implementation. This report includes the results of the first two phases. A total of 2,693 specimens (both whole blood and plasma) were included in the evaluation. Results were compared to double Enzyme Linked Immuno-Sorbent Assay (ELISA) system. Discordant EIA results were resolved using Western Blot. The assays had very good sensitivities and specificities, 99-100%, at the two different phases of the evaluation. A 98-100% result agreement was obtained from those tested at VCT centers and National Referral Laboratory for AIDS (NRLA), in the quality control phase of the evaluation. A testing strategy yielding 100% [95% CI; 98.9-100.0] sensitivity was achieved by the sequential use of the three rapid test kits. Direct cost comparison showed serial testing algorithm reduces the cost of testing by over 30% compared to parallel testing in the current situation. Determine, Capillus/Oraquick (presence/absence of frefrigeration) and Unigold were recommended as screening, confirmation and tiebreaker tests, respectively.

  16. Comparison of Three Screening Test Kits for G6PD Enzyme Deficiency: Implications for Its Use in the Radical Cure of Vivax Malaria in Remote and Resource-Poor Areas in the Philippines.

    Directory of Open Access Journals (Sweden)

    Fe Esperanza Espino

    Full Text Available We evaluated a battery of Glucose-6-Phosphate Dehydrogenase diagnostic point-of-care tests (PoC to assess the most suitable product in terms of performance and operational characteristics for remote areas.Samples were collected in Puerto Princesa City, Palawan, Philippines and tested for G6PD deficiency with a fluorescent spot test (FST; Procedure 203, Trinity Biotech, Ireland, the semiquantitative WST8/1-methoxy PMS (WST; Dojindo, Japan and the Carestart G6PD Rapid Diagnostic Test (CSG; AccessBio, USA. Results were compared to spectrophotometry (Procedure 345, Trinity Biotech, Ireland. Sensitivity and specificity were calculated for each test with cut-off activities of 10%, 20%, 30% and 60% of the adjusted male median.The adjusted male median was 270.5 IU/10(12 RBC. FST and WST were tested on 621 capillary blood samples, the CSG was tested on venous and capillary blood on 302 samples. At 30% G6PD activity, sensitivity for the FST was between 87.7% (95%CI: 76.8% to 93.9% and 96.5% (95%CI: 87.9% to 99.5% depending on definition of intermediate results; the WST was 84.2% (95%CI: 72.1% to 92.5%; and the CSG was between 68.8% (95%CI: 41.3% to 89.0% and 93.8% (95%CI: 69.8% to 99.8% when the test was performed on capillary or venous blood respectively. Sensitivity of FST and CSG (tested with venous blood were comparable (p>0.05. The analysis of venous blood samples by the CSG yielded significantly higher results than FST and CSG performed on capillary blood (p<0.05. Sensitivity of the CSG varied depending on source of blood used (p<0.05.The operational characteristics of the CSG were superior to all other test formats. Performance and operational characteristics of the CSG performed on venous blood suggest the test to be a good alternative to the FST.

  17. Validation of the BetaStar® Advanced for Beta-lactams Test Kit for the Screening of Bulk Tank and Tanker Truck Milks for the Presence of Beta-lactam Drug Residues.

    Science.gov (United States)

    Denhartigh, Andrew; Reynolds, Lindsay; Palmer, Katherine; Klein, Frank; Rice, Jennifer; Rejman, John J

    2018-05-18

    A validation study was conducted for an immunochromatographic method (BetaStar ® Advanced for Beta-lactams) for the detection of beta-lactam residues in raw, commingled bovine milk. The assay detected amoxicillin, ampicillin, cloxacillin, penicillin, cephapirin, and ceftiofur below the U.S. Food and Drug Administration tolerance levels but above the maximum sensitivity thresholds established by the National Conference on Interstate Milk Shipments. The results of internal and independent laboratory dose-response studies employing spiked samples were in agreement. The test detected all six drugs at the approximate 90/95% sensitivity levels in milk from cows treated with each drug. Selectivity of the assay was 100%, as no false-positive results were obtained in testing 1148 control milk samples. Testing the estimated 90/95% sensitivity level for amoxicillin (8.5 ppb), ampicillin (6.9 ppb), cloxacillin (8.9 ppb), penicillin (4.2 ppb), and cephapirin (17.6 ppb), and at 100 ppb for each antibiotic, resulted in 94-100% positive tests for each of the beta-lactam drugs. The results of ruggedness experiments established the operating parameter tolerances for the assay. Cross-reactivity testing established that the assay detects other certain beta-lactam drugs, but it does not cross-react with any of 30 drugs belonging to seven different drug classes. Abnormally high bacterial or somatic cell counts in raw milk produced no assay interference.

  18. Screening Tests for Birth Defects

    Science.gov (United States)

    ... that best fit your needs. What are the advantages and disadvantages of diagnostic tests compared with screening ... Us Contact Us Copyright Information Privacy Statement RSS Advertising Opportunities Careers at ACOG Sitemap Website Feedback American ...

  19. Newborn Screening Tests

    Science.gov (United States)

    ... don't have enough biotinidase, an enzyme that recycles biotin (a B vitamin) in the body. Biotinidase ... about additional tests: Do you have a family history of an inherited disorder? Have you previously given ...

  20. Sensitive KIT D816V mutation analysis of blood as a diagnostic test in mastocytosis

    DEFF Research Database (Denmark)

    Kielsgaard Kristensen, Thomas; Vestergaard, Hanne; Bindslev-Jensen, Carsten

    2014-01-01

    The recent progress in sensitive KIT D816V mutation analysis suggests that mutation analysis of peripheral blood (PB) represents a promising diagnostic test in mastocytosis. However, there is a need for systematic assessment of the analytical sensitivity and specificity of the approach in order...... to establish its value in clinical use. We therefore evaluated sensitive KIT D816V mutation analysis of PB as a diagnostic test in an entire case-series of adults with mastocytosis. We demonstrate for the first time that by using a sufficiently sensitive KIT D816V mutation analysis, it is possible to detect...... the mutation in PB in nearly all adult mastocytosis patients. The mutation was detected in PB in 78 of 83 systemic mastocytosis (94%) and 3 of 4 cutaneous mastocytosis patients (75%). The test was 100% specific as determined by analysis of clinically relevant control patients who all tested negative. Mutation...

  1. Review of Autism Screening Tests

    Directory of Open Access Journals (Sweden)

    Farin Soleimani

    2014-10-01

    Full Text Available Background: Autism is a neurodevelopmental disorder that onset in the first 3 years of life and led to lifelong disability.Despite the early onset of symptoms, diagnosis of thissyndromedoes not happenuntil severalyears later, somany childrenlosethe opportunityfor earlyintervention.There arevarious toolsforscreening anddiagnosis, buttheirdesign, strengths and weaknesses aredifferent. The aim of this study was assess these tools from various aspects to provide a comprehensive view. Materials and methods: This study is a narrative literature review on screeningtoolsof autism. Comprehensive searches of the scientific literature were conducted in textbooks and 8 electronic databases(proquest,wiley,google scholar,SID,Scopus, Web of Science ،Science Direct ، and Medline and Pediatric book. language restriction (Persian and English was applied. The search strategy consisted of keywords and medical subject headings for autism and various screening tests. Result: In this study, 28 screening tests were identified from 1992 to 2014. CHAT is oldest test and the most recent test is CAST The minimum age that can perform the screening is six months that related to ITC. Minimum time of testing was 5 minutes  for CHAT and the maximum time was 90-120 minutes for ASIEP-3.RAADS-R test was the highest specificity and specificity (100% and the lowest specificity was 14% in ESAT test Conclusion: The results of this study indicate that any of the autism screening tools consider specific skill and various aspects of the disease, careful evaluation is need to choose proper test.

  2. Evaluation of nine HIV rapid test kits to develop a national HIV testing algorithm in Nigeria

    Directory of Open Access Journals (Sweden)

    Orji Bassey

    2015-05-01

    Full Text Available Background: Non-cold chain-dependent HIV rapid testing has been adopted in many resource-constrained nations as a strategy for reaching out to populations. HIV rapid test kits (RTKs have the advantage of ease of use, low operational cost and short turnaround times. Before 2005, different RTKs had been used in Nigeria without formal evaluation. Between 2005 and 2007, a study was conducted to formally evaluate a number of RTKs and construct HIV testing algorithms. Objectives: The objectives of this study were to assess and select HIV RTKs and develop national testing algorithms. Method: Nine RTKs were evaluated using 528 well-characterised plasma samples. These comprised 198 HIV-positive specimens (37.5% and 330 HIV-negative specimens (62.5%, collected nationally. Sensitivity and specificity were calculated with 95% confidence intervals for all nine RTKs singly and for serial and parallel combinations of six RTKs; and relative costs were estimated. Results: Six of the nine RTKs met the selection criteria, including minimum sensitivity and specificity (both ≥ 99.0% requirements. There were no significant differences in sensitivities or specificities of RTKs in the serial and parallel algorithms, but the cost of RTKs in parallel algorithms was twice that in serial algorithms. Consequently, three serial algorithms, comprising four test kits (BundiTM, DetermineTM, Stat-Pak® and Uni-GoldTM with 100.0% sensitivity and 99.1% – 100.0% specificity, were recommended and adopted as national interim testing algorithms in 2007. Conclusion: This evaluation provides the first evidence for reliable combinations of RTKs for HIV testing in Nigeria. However, these RTKs need further evaluation in the field (Phase II to re-validate their performance.

  3. Chemical compatibility screening test results

    International Nuclear Information System (INIS)

    Nigrey, P.J.; Dickens, T.G.

    1997-12-01

    A program for evaluating packaging components that may be used in transporting mixed-waste forms has been developed and the first phase has been completed. This effort involved the screening of ten plastic materials in four simulant mixed-waste types. These plastics were butadiene-acrylonitrile copolymer rubber, cross-linked polyethylene (XLPE), epichlorohydrin rubber, ethylene-propylene rubber (EPDM), fluorocarbon (Viton or Kel-F), polytetrafluoroethylene, high-density polyethylene (HDPE), isobutylene-isoprene copolymer rubber (butyl), polypropylene, and styrene-butadiene rubber (SBR). The selected simulant mixed wastes were (1) an aqueous alkaline mixture of sodium nitrate and sodium nitrite; (2) a chlorinated hydrocarbon mixture; (3) a simulant liquid scintillation fluid; and (4) a mixture of ketones. The testing protocol involved exposing the respective materials to 286,000 rads of gamma radiation followed by 14-day exposures to the waste types at 60 degrees C. The seal materials were tested using vapor transport rate (VTR) measurements while the liner materials were tested using specific gravity as a metric. For these tests, a screening criterion of 0.9 g/hr/m 2 for VTR and a specific gravity change of 10% was used. Based on this work, it was concluded that while all seal materials passed exposure to the aqueous simulant mixed waste, EPDM and SBR had the lowest VTRs. In the chlorinated hydrocarbon simulant mixed waste, only Viton passed the screening tests. In both the simulant scintillation fluid mixed waste and the ketone mixture simulant mixed waste, none of the seal materials met the screening criteria. For specific gravity testing of liner materials, the data showed that while all materials with the exception of polypropylene passed the screening criteria, Kel-F, HDPE, and XLPE offered the greatest resistance to the combination of radiation and chemicals

  4. A comparative study in three commercial kits of radioligand assay for GAD-Ab

    International Nuclear Information System (INIS)

    Yang Yehua; Zhou Zhiguang; Huang Gan; Yang Feike; Li Zhangwei

    2006-01-01

    Objective: To provide data for perfect selection of glutamic acid decarboxylase antibodies (GAD-Ab) assay commercial kits. Methods: The sera of 88 titer-graded samples by radioligand assay (RLA) were measured with two types of enzyme-linked immunosorbent assay (ELISA) kits and one type of immunoradiometric assay (IRMA) kit for GAD-Ab in order to test their consistency with RLA. Another 140 diabetic sera were measured with RLA and screened by a type of suitable kit to search the cutoff point for discriminating patients who needed rechecking. Results: Compared with RLA, concordance ratio of 3 kits: Medizym kit(75%) > RSR kit(73.9%) > Biomerica kit(62.5%); Kappa value: Medizym kit (0.408, common) > RSR kit (0.405, common) > Biomerica kit (0.185, failing); correlation to RLA index: RSR kit (r= 0.992) > Medizym kit(r= 0. 791 ) > Biomerica kit (r = -0. 055); area under the receiver operating characteristic (ROC) curve: Medizym kit (0.812) > RSR kit (0. 727 ) > Biomerica kit (0.666). Conclusions: The efficiencies of RSR kit and Medizym kit are good. Serum concentration between 0.25-0.99 U/ml measured by RSR kit is suggested to further recheck by RLA. (authors)

  5. Diagnosis efficiency of urine malaria test kit for the diagnosis of ...

    African Journals Online (AJOL)

    The aim of this study was to determine the diagnostic efficiencies of urine malaria test kit with microscopy as the gold standard in detecting Plasmodium falciparum HRP-2, a poly-histidine antigen in urine of febrile patients. The study was conducted in a primary and secondary health institution in Gombe Town, Gombe State, ...

  6. Self-Test Kit: Rapid Diagnosis of Urogenital Infections in Military Women

    Science.gov (United States)

    1999-09-01

    this project will result in a self-test kit for use on deployment and/or in other resource poor environments. 14. SUBJECT TERMS 15. N1 tUMER OF PAGES...DK, et al. Characteristics of women by smoking status in the San Francisco Bay Area. Cancer Epidemiology, Biomarkers and Prevention, 1992; 1:491-7. 10

  7. A simple kit for rapid field diagnosis of potato virus Y by latex serological test

    Directory of Open Access Journals (Sweden)

    Aarne Kurppa

    1987-07-01

    Full Text Available A simple kit for rapid detection of potato virus Y by latex serological test was developed. The test is carried out on a white cardboard sheet and the results can be read by naked eye in two minutes. A test card of 10 x 6 cm holds latex sensitized antibodies, buffers and other necessary ingredients as dry blue colored formulate on the ringed areas of the card. A test card includes space for six tests and positive and negative controls. The kit also includes disposable plastic sticks for mixing the samples with test reagents and a hand press with disposable plastic tips. For testing, dried reagents are dissolved in drops of sample and mixed. After gentle rotation, samples containing virus appear clearly granulated while samples from healthy plants remain unagglutinated. The testing of undiluted extracts of evenly developed tuber sprouts resulted in over 91 % identity with the results obtained with ELISA that was used as a control method. Testing of diluted leaf extracts reached the same reliability but undiluted leaf extracts from glasshouse grown potatoes were not well suitable as test samples because of their dark green color. No such problems occurred with field grown material and a complete identity with the ELISA readings was true when the samples included secondarily infected potato plants. No reaction to other potato viruses than PVY was obtained by the test kit.

  8. Evaluation of Commercially Available Cyanide Test Kits against Various Matrices

    Science.gov (United States)

    2016-08-01

    commercial products. This report may not be cited for purposes of advertisement . Acknowledgments The authors acknowledge the hard work...Sigma-Aldrich);  DG Clover Valley coffee creamer (Lot 09603235 9864 2048); and  Powdered milk ( Nestle ; Vevey, Switzerland). 2. PHASE I TESTING

  9. Field kit and method for testing for the presence of gunshot residue

    Science.gov (United States)

    Rodacy, Philip J.; Walker, Pamela K.

    2003-09-02

    A field test kit for gunshot residue comprises a container having at least compartments separated by a barrier. A surface is tested by wiping it with a swab and placing the swab in a first compartment. The barrier is then breached, permitting reagent in the second compartment to flow onto the swab. The first compartment is transparent, and a color change will be observed if the reagent reacts with gunshot residue.

  10. Evaluation of a rapid immunodiagnostic test kit for detection of African lyssaviruses from brain material

    Directory of Open Access Journals (Sweden)

    W. Markotter

    2009-09-01

    Full Text Available Rapid immunodiagnostic test kit was evaluated against a selection of isolates of lyssavirus genotypes occurring in Africa. The test was carried out in parallel comparison with the fluorescent antibody test (FAT and isolates representing previously established phylogenetic groups from each genotype were included. The specificity of the rapid immunodiagnostic test compared favourably with the FAT and was found to detect all representatives of genotypes 1, 2, 3 and 4 in brain samples of either field cases or suckling mouse brain inoculates.

  11. Samsung Salmonella Detection Kit. AOAC Performance Tested Method(SM) 021203.

    Science.gov (United States)

    Li, Jun; Cheung, Win Den; Opdyke, Jason; Harvey, John; Chong, Songchun; Moon, Cheol Gon

    2012-01-01

    Salmonella, one of the most common causes of foodborne illness, is a significant public health concern worldwide. There is a need in the food industry for methods that are simple, rapid, and sensitive for the detection of foodborne pathogens. In this study, the Samsung Salmonella Detection Kit, a real-time PCR assay for the detection of Salmonella, was evaluated according to the current AOAC guidelines. The validation consisted of lot-to-lot consistency, stability, robustness, and inclusivity/exclusivity studies, as well as a method comparison of 10 different food matrixes. In the validation, the Samsung Salmonella Detection Kit was used in conjunction with the Applied Biosystems StepOnePlus PCR system and the Samsung Food Testing Software for the detection of Salmonella species. The performance of the assays was compared to the U.S. Department of Agriculture/Food Safety and Inspection Service-Microbiology Laboratory Guidebook (USDA/FSIS-MLG) 4.05: Isolation and Identification of Salmonella from Meat, Poultry, Pasteurized Egg, and Catfish and the and U.S. Food and Drug Administration/Bacteriological Analytical Manual (FDA/BAM) Chapter 5 Salmonella reference methods. The validation was conducted using an unpaired study design for detection of Salmonella spp. in raw ground beef, raw pork, raw ground pork, raw chicken wings, raw salmon, alfalfa sprouts, pasteurized orange juice, peanut butter, pasteurized whole milk, and shell eggs. The Samsung Salmonella Detection Kit demonstrated lot-to-lot consistency among three independent lots as well as ruggedness with minor modifications to changes in enrichment incubation time, enrichment incubation temperature, and DNA sample volume for PCR reaction. Stability was observed for 13 months at -20 degrees C and 3 months at 5 degrees C. For the inclusivity/exclusivity study, the Samsung Salmonella Detection Kit correctly identified 147 Salmonella species isolates out of 147 isolates tested from each of three different enrichment

  12. Testing Precision Screening for Breast Cancer

    Science.gov (United States)

    An NCI research article about individualized approaches that could help identify those at risk of breast cancer who need to be screened and testing screening intervals that are appropriate for each person’s level of risk.

  13. Nationwide study of factors associated with public's willingness to use home self-test kit for dengue fever in Malaysia.

    Science.gov (United States)

    Wong, Li Ping; Atefi, Narges; AbuBakar, Sazaly

    2016-08-12

    As there is no specific treatment for dengue, early detection and access to proper treatment may lower dengue fatality. Therefore, having new techniques for the early detection of dengue fever, such as the use of dengue test kit, is vitally important. The aims of the study were: 1) identify factors associated with acceptance of a home self-test kit for dengue fever if the dengue test is available to the public and 2) find out the characteristics of the test kits that influence the use of the dengue test kit. A national telephone survey was carried out with 2,512 individuals of the Malaysian public aged 18-60 years old. Individuals were contacted by random digit dialling covering the whole of Malaysia from February 2012 to June 2013. From 2,512 participants, 6.1 % reported to have heard of the availability of the dengue home test kit and of these, 44.8 % expressed their intention to use the test kit if it was available. Multivariate logistic regressions indicated that participants with primary (OR: 0.65; 95 % CI: 0.43-0.89; p = 0.02, vs. tertiary educational level) and secondary educational levels (OR: 0.73; 95 % CI: 0.57-0.90; p = 0.01, vs. tertiary educational level) were less likely than participants with a tertiary educational level to use a home self-testing dengue kit for dengue if the kit was available. Participants with lower perceived barriers to dengue prevention (level of barriers 0-5) were less likely (OR: 0.67, 95 % CI: 0.53-0.85, p dengue kit for dengue if the kit was available compared to those with higher perceived barriers to dengue prevention (level of barriers 6-10). Participants with a lower total dengue fever knowledge score (range 0-22) were also less likely to use a home self-testing dengue kit for dengue if the kit was available (OR: 0.75; 95 % CI: 0.61-0.91, p = 0.001, vs. higher total dengue fever knowledge score) compared to those with a higher total dengue fever knowledge score (range 23-44). With response to

  14. Acceptability of using electronic vending machines to deliver oral rapid HIV self-testing kits: a qualitative study.

    Directory of Open Access Journals (Sweden)

    Sean D Young

    Full Text Available Rates of unrecognized HIV infection are significantly higher among Latino and Black men who have sex with men (MSM. Policy makers have proposed that HIV self-testing kits and new methods for delivering self-testing could improve testing uptake among minority MSM. This study sought to conduct qualitative assessments with MSM of color to determine the acceptability of using electronic vending machines to dispense HIV self-testing kits.African American and Latino MSM were recruited using a participant pool from an existing HIV prevention trial on Facebook. If participants expressed interest in using a vending machine to receive an HIV self-testing kit, they were emailed a 4-digit personal identification number (PIN code to retrieve the test from the machine. We followed up with those who had tested to assess their willingness to participate in an interview about their experience.Twelve kits were dispensed and 8 interviews were conducted. In general, participants expressed that the vending machine was an acceptable HIV test delivery method due to its novelty and convenience.Acceptability of this delivery model for HIV testing kits was closely associated with three main factors: credibility, confidentiality, and convenience. Future research is needed to address issues, such as user-induced errors and costs, before scaling up the dispensing method.

  15. Acceptability of using electronic vending machines to deliver oral rapid HIV self-testing kits: a qualitative study.

    Science.gov (United States)

    Young, Sean D; Daniels, Joseph; Chiu, ChingChe J; Bolan, Robert K; Flynn, Risa P; Kwok, Justin; Klausner, Jeffrey D

    2014-01-01

    Rates of unrecognized HIV infection are significantly higher among Latino and Black men who have sex with men (MSM). Policy makers have proposed that HIV self-testing kits and new methods for delivering self-testing could improve testing uptake among minority MSM. This study sought to conduct qualitative assessments with MSM of color to determine the acceptability of using electronic vending machines to dispense HIV self-testing kits. African American and Latino MSM were recruited using a participant pool from an existing HIV prevention trial on Facebook. If participants expressed interest in using a vending machine to receive an HIV self-testing kit, they were emailed a 4-digit personal identification number (PIN) code to retrieve the test from the machine. We followed up with those who had tested to assess their willingness to participate in an interview about their experience. Twelve kits were dispensed and 8 interviews were conducted. In general, participants expressed that the vending machine was an acceptable HIV test delivery method due to its novelty and convenience. Acceptability of this delivery model for HIV testing kits was closely associated with three main factors: credibility, confidentiality, and convenience. Future research is needed to address issues, such as user-induced errors and costs, before scaling up the dispensing method.

  16. Thyroxine determination in serum by radioimmunoassay and competitive protein-binding analysis (simultaneous study using four test kits)

    International Nuclear Information System (INIS)

    Wagner, K.

    1978-01-01

    Three commercial test kits for radioimmunological T 4 -determination have been tested (T 4 -RIA Abbott, RIA-mat T 4 , T 4 -RIA Henning). The RIA method has also been compared with a CPBA test (Tetralute) for routine application. 1) The results show that CPBA (Tetralute) is superior over the three radioimmuno-assays with regard to intra-assay variance. The T 4 -RIA Abbott has been inferior to the two other RIA under test and to the Tetralute with regard to inter-assay variance. 2) The four test kits show significant differences and considerable deviations from the given nominal values in comparison with the mean values of two control sera. A control for correctness does not seem to be appropriate as it cannot be decided which of the test kits yields the true value of T 4 content. No systematic difference has been observed between RIA and CPBA in the determination of T 4 in control sera. 3) No detectable difference has been found among the RIA-T 4 test kits and comparing them with the CBPA test regarding their diagnostic precision. A good correlation of T 4 values of euthyroid patients comparing the Tetralute and the three radioimmunological test kits. The mean values of euthyroid sera obtained by the three radioimmuno-assays and the Tetralute are not in agreement with each other. (orig.) [de

  17. Quality and use of consumer information provided with home test kits: room for improvement.

    Science.gov (United States)

    Grispen, Janaica E J; Ickenroth, Martine H P; de Vries, Nanne K; van der Weijden, Trudy; Ronda, Gaby

    2014-10-01

    Diagnostic self-tests (tests on body materials that are initiated by consumers with the aim of diagnosing a disorder or risk factor) are becoming increasingly available. Although the pros and cons of self-testing are currently not clear, it is an existing phenomenon that is likely to gain further popularity. To examine consumers' use of and needs for information about self-testing, and to assess the quality of consumer information provided with home test kits, as perceived by consumers and as assessed using a checklist of quality criteria. A cross-sectional Internet survey among 305 self-testers assessed their use of and needs for information and their perception of the quality of consumer information provided with self-test kits. A meta-search engine was used to identify Dutch and English consumer information for home diagnostic tests available online at the time of the study. The quality of this consumer information was evaluated using a checklist of quality criteria. The consumers' information needs were in line with the most frequently used information, and the information was perceived as being of moderate to good quality. The information was mostly in agreement with clinical practice guidelines, although information on reliability and follow-up behaviour was limited. Approximately half of the instruction leaflets did not include information on the target group of the test. Although generally of moderate to good quality, some aspects of the information provided were in many cases insufficient. European legislation concerning self-tests and accompanying information needs to be adapted and adhered to more closely. © 2012 John Wiley & Sons Ltd.

  18. Gyrotron development at KIT: FULGOR test facility and gyrotron concepts for DEMO

    Energy Technology Data Exchange (ETDEWEB)

    Schmid, M., E-mail: martin.schmid@kit.edu [Institute for Pulsed Power and Microwave Technology (IHM), Karlsruhe Institute of Technology, Association EURATOM-KIT, Karlsruhe (Germany); Franck, J.; Kalaria, P.; Avramidis, K.A.; Gantenbein, G.; Illy, S. [Institute for Pulsed Power and Microwave Technology (IHM), Karlsruhe Institute of Technology, Association EURATOM-KIT, Karlsruhe (Germany); Jelonnek, J. [Institute for Pulsed Power and Microwave Technology (IHM), Karlsruhe Institute of Technology, Association EURATOM-KIT, Karlsruhe (Germany); Institute of High Frequency Techniques and Electronics (IHE), Karlsruhe Institute of Technology, Association EURATOM-KIT, Karlsruhe (Germany); Pagonakis, I. Gr.; Rzesnicki, T. [Institute for Pulsed Power and Microwave Technology (IHM), Karlsruhe Institute of Technology, Association EURATOM-KIT, Karlsruhe (Germany); Thumm, M. [Institute for Pulsed Power and Microwave Technology (IHM), Karlsruhe Institute of Technology, Association EURATOM-KIT, Karlsruhe (Germany); Institute of High Frequency Techniques and Electronics (IHE), Karlsruhe Institute of Technology, Association EURATOM-KIT, Karlsruhe (Germany)

    2015-10-15

    Highlights: • Substantial extension of the KIT gyrotron test facility FULGOR has started. • FULGOR will be able to test gyrotrons with continuous RF output power up to 4 MW. • Design of 240 GHz gyrotrons for efficient electron cyclotron current drive is progressing. • Output power of 240 GHz gyrotrons with conventional cavity up to 830 kW, with coaxial cavity up to 2 MW is feasible. • Multi-frequency operation with gyrotrons is also possible (170–267 GHz). - Abstract: At the Karlsruhe Institute of Technology (KIT), theoretical and experimental foundations for the development of future gyrotrons for fusion applications are being laid down. This includes the construction of the new Fusion Long Pulse Gyrotron Laboratory (FULGOR) test facility as well as physical design studies towards DEMO-compatible gyrotrons. Initially FULGOR will comprise of a 10 MW CW power supply, a 5 MW water cooling system (upgradeable to 10 MW), a superconducting 10 T magnet, one or two 2 MW ECRH test loads and a new control and data acquisition system for all these elements. The test facility will then be equipped to test the conventional 1 MW or coaxial 2 MW gyrotrons for DEMO, currently under design, as well as possible upgraded gyrotrons for W7-X and ITER. The design of the new high voltage DC power supply (HVDCPS) is flexible enough to handle gyrotrons with 4 MW CW output power (conceivably up to 170 GHz), but also test gyrotrons with higher frequencies (>250 GHz) which, due to physical limitations in the gyrotron design, will require less power but have more stringent demands on voltage stability.

  19. A community-based trial of educational interventions with fecal immunochemical tests for colorectal cancer screening uptake among blacks in community settings.

    Science.gov (United States)

    Christy, Shannon M; Davis, Stacy N; Williams, Kimberly R; Zhao, Xiuhua; Govindaraju, Swapomthi K; Quinn, Gwendolyn P; Vadaparampil, Susan T; Lin, Hui-Yi; Sutton, Steven K; Roethzeim, Richard R; Shibata, David; Meade, Cathy D; Gwede, Clement K

    2016-11-15

    Intervention studies among individuals in diverse community settings are needed to reduce health disparities in colorectal cancer (CRC) screening and mortality rates. The current study compared the efficacy of 2 intervention conditions promoting CRC screening among black individuals. Black individuals ages 50 to 75 years (N = 330) were recruited in community settings in 4 Tampa Bay counties. After obtaining consent and conducting a baseline interview to assess sociodemographic and health-related variables, participants received either a culturally targeted CRC photonovella booklet plus a fecal immunochemical test (FIT) kit or a standard CRC screening brochure plus an FIT kit. The primary outcome was FIT kit screening uptake. FIT screening uptake at 6 months was 86.7% overall (90.3% in the brochure group and 81.9% in the photonovella group). Controlling for baseline between-group differences, there was no influence of intervention on FIT kit uptake (P = .756). Significant predictors of not returning an FIT kit included being unable to work (P = .010), having higher religious belief scores (P = .015), and living farther from the cancer center (P = .015). Providing FIT kits and educational print materials to black individuals in community settings resulted in high rates of CRC screening. The study also identified subgroups of participants who were less likely to return an FIT kit and provides insight for future interventions. Cancer 2016;122:3288-3296. © 2016 American Cancer Society. © 2016 American Cancer Society.

  20. High-throughput screening of carbohydrate-degrading enzymes using novel insoluble chromogenic substrate assay kits

    DEFF Research Database (Denmark)

    Schückel, Julia; Kracun, Stjepan Kresimir; Willats, William George Tycho

    2016-01-01

    for this is that advances in genome and transcriptome sequencing, together with associated bioinformatics tools allow for rapid identification of candidate CAZymes, but technology for determining an enzyme's biochemical characteristics has advanced more slowly. To address this technology gap, a novel high-throughput assay...... CPH and ICB substrates are provided in a 96-well high-throughput assay system. The CPH substrates can be made in four different colors, enabling them to be mixed together and thus increasing assay throughput. The protocol describes a 96-well plate assay and illustrates how this assay can be used...... for screening the activities of enzymes, enzyme cocktails, and broths....

  1. Forgotten evidence: A mixed methods study of why sexual assault kits (SAKs) are not submitted for DNA forensic testing.

    Science.gov (United States)

    Campbell, Rebecca; Fehler-Cabral, Giannina; Bybee, Deborah; Shaw, Jessica

    2017-10-01

    Throughout the United States, hundreds of thousands of sexual assault kits (SAKs) (also termed "rape kits") have not been submitted by the police for forensic DNA testing. DNA evidence can help sexual assault investigations and prosecutions by identifying offenders, revealing serial offenders through DNA matches across cases, and exonerating those who have been wrongly accused. In this article, we describe a 5-year action research project conducted with 1 city that had large numbers of untested SAKs-Detroit, Michigan-and our examination into why thousands of rape kits in this city were never submitted for forensic DNA testing. This mixed methods study combined ethnographic observations and qualitative interviews to identify stakeholders' perspectives as to why rape kits were not routinely submitted for testing. Then, we quantitatively examined whether these factors may have affected police practices regarding SAK testing, as evidenced by predictable changes in SAK submission rates over time. Chronic resource scarcity only partially explained why the organizations that serve rape victims-the police, crime lab, prosecution, and victim advocacy-could not test all rape kits, investigate all reported sexual assaults, and support all rape survivors. SAK submission rates significantly increased once criminal justice professionals in this city had full access to the FBI DNA forensic database Combined DNA Index System (CODIS), but even then, most SAKs were still not submitted for DNA testing. Building crime laboratories' capacities for DNA testing and training police on the utility of forensic evidence and best practices in sexual assault investigations can help remedy, and possibly prevent, the problem of untested rape kits. (PsycINFO Database Record (c) 2017 APA, all rights reserved).

  2. The clinical testing of a Hungarian-made triiodothyronine radioimmunoassay kit

    International Nuclear Information System (INIS)

    Gyertyanfy, G.; Foeldes, J.

    1981-01-01

    The parameters of the calibration curve of the new Hungarian RK-11 kit for the determination of the total T3 content of the serum and the reliability of the results were studied. The data of the measurements made on a number of patients by RK-11, Biodata and Byk-Mallinckrodt kits were compared. The new kit seems to be applicable to the determination of the total T3 content in the serum. (author)

  3. Performances of Four Helicobacter pylori Serological Detection Kits Using Stool Antigen Test as Gold Standard.

    Directory of Open Access Journals (Sweden)

    Susheela D Biranjia-Hurdoyal

    Full Text Available The aim was to determine the performances of four Helicobacter pylori serological detection kits in different target groups, using Amplified IDEIA™ Hp StAR™ as gold standard. Kits studied were Rapid Immunochromatoghraphic Hexagon, Helicoblot 2.1, an EIA IgG kit and EIA IgA kit.Stool and blood samples were collected from 162 apparently healthy participants (control and 60 Type 2 diabetes mellitus (T2DM patients.The performances of the four serological detection kits were found to be affected by gender, age, health status and ethnicity of the participants. In the control group, the Helicoblot 2.1 kit had the best performance (AUC = 0.85; p<0.05, accuracy = 86.4%, followed by EIA IgG (AUC = 0.75; p<0.05, accuracy = 75.2%. The Rapid Hexagon and EIA IgA kits had relatively poor performances. In the T2DM subgroup, the kits H2.1 and EIA IgG had best performances, with accuracies of 96.5% and 93.1% respectively. The performance of EIA IgG improved with adjustment of its cut-off value.The performances of the detection kits were affected by various factors which should be taken into consideration.

  4. [Clinical evaluation of triage as drug-of-abuse test kit].

    Science.gov (United States)

    Yoshioka, Toshiharu; Kohriyama, Kazuaki; Kondo, Rumiko; Goto, Kyoko; Yashiki, Mikio

    2003-01-01

    There are about 60,000 chemical substances which may cause poisoning. Identifying the cause substances is, therefore, very important for patient at emergency department. Triage is an immunoassay kit for the qualitative test for the metabolites of 8 major abuse drugs in urine. We assessed the usefullness of Triage on two patient groups. The first Group consists of the patients considered having not taken substances at initial diagnosis; the second Group consists of the patients considered having taken substances. The result are as follows. 1) The rate of Triage positive patients in the first Group were: attempt-suicide 23%, coma 24%, shock 10%, trauma 7%, respectively. Except for the habitually used medicine, narcotic and stimulant drugs were detected. In the first Group, negative result of Triage was effective in diagnosing the patients as not poisoned, excluding the possitivity of 8 major drugs usage. 2) The rate of Triage positive patients in the second Group were very high: attempt-suicide 77%, coma 51%, shock 57%, trauma 30%, respectively, showing mostly any of 8 major drugs were the cause of poisoning. In the second Group, positive result of Triage was effective in diagnosing the patient as poisoning or as coexisting poisoning with other diseases. 3) The specificity of Triage diagnosis in the first Group was 80% (113/142). The specificity and the sensitivity in the second Group were 64% (50/78) and 97% (74/76), respectively. These results means that Triage is very useful for diagnosis on 8 major drugs poisoning. 4) Triage is efficient for identifying the cause substances in drug poisoning and, therefore, can save medical expense. Triage is a very useful test kit at emergency department.

  5. Performances of Four Helicobacter pylori Serological Detection Kits Using Stool Antigen Test as Gold Standard.

    Science.gov (United States)

    Biranjia-Hurdoyal, Susheela D; Seetulsingh-Goorah, Sharmila P

    2016-01-01

    The aim was to determine the performances of four Helicobacter pylori serological detection kits in different target groups, using Amplified IDEIA™ Hp StAR™ as gold standard. Kits studied were Rapid Immunochromatoghraphic Hexagon, Helicoblot 2.1, an EIA IgG kit and EIA IgA kit. Stool and blood samples were collected from 162 apparently healthy participants (control) and 60 Type 2 diabetes mellitus (T2DM) patients. The performances of the four serological detection kits were found to be affected by gender, age, health status and ethnicity of the participants. In the control group, the Helicoblot 2.1 kit had the best performance (AUC = 0.85; ppoor performances. In the T2DM subgroup, the kits H2.1 and EIA IgG had best performances, with accuracies of 96.5% and 93.1% respectively. The performance of EIA IgG improved with adjustment of its cut-off value. The performances of the detection kits were affected by various factors which should be taken into consideration.

  6. Screening and Invasive Testing in Twins

    Directory of Open Access Journals (Sweden)

    Giovanni Monni

    2014-07-01

    Full Text Available Prenatal screening and testing for trisomy 21 in twin pregnancies poses a number of challenges: the exact estimate of the a priori risk of trisomy 21, the choice of prenatal screening test and/or invasive techniques to employ for the diagnosis and the impact of the result on the options of treatment in case of discordant results within a twin pair or among multiples. These different aspects are discussed below while recognizing that many issues remain unresolved.

  7. [Generalized neonatal screening based on laboratory tests].

    Science.gov (United States)

    Ardaillou, Raymond; Le Gall, Jean-Yves

    2006-11-01

    Implementation of a generalized screening program for neonatal diseases must obey precise rules. The disease must be severe, recognizable at an early stage, amenable to an effective treatment, detectable with a non expensive and widely applicable test; it must also be a significant public health problem. Subjects with positive results must be offered immediate treatment or prevention. All screening programs must be regularly evaluated. In France, since 1978, a national screening program has been organized by a private association ("Association française pour le dépistage et la prévention des handicaps de l'enfant") and supervised by the "Caisse nationale d'assurance maladie" and "Direction Générale de la Sante". Five diseases are now included in the screening program: phenylketonuria, hypothyroidism, congenital adrenal hyperplasia, cystic fibrosis and sickle cell disease (the latter only in at-risk newborns). Toxoplasmosis is a particular problem because only the children of mothers who were not tested during the pregnancy or who seroconverted are screened. Neonatal screening for phenylketonuria and hypothyrodism is unanimously recommended. Screening for congenital adrenal hyperplasia is approved in most countries. Cases of sickle cell disease and cystic fibrosis are more complex because--not all children who carry the mutations develop severe forms;--there is no curative treatment;--parents may become anxious, even though the phenotype is sometimes mild or even asymptomatic. Supporters of screening stress the benefits of early diagnosis (which extends the life expectancy of these children, particularly in the case of sickle cell disease), the fact that it opens up the possibility of prenatal screening of future pregnancies, and the utility of informing heterozygous carriers identified by familial screening. Neonatal screening for other diseases is under discussion. Indeed, technical advances such as tandem mass spectrometry make it possible to detect about 50

  8. Reactor operator screening test experiences

    International Nuclear Information System (INIS)

    O'Brien, W.J.; Penkala, J.L.; Witzig, W.F.

    1976-01-01

    When it became apparent to Duquesne Light Company of Pittsburgh, Pennsylvania, that the throughput of their candidate selection-Phase I training-reactor operator certification sequence was something short of acceptable, the utility decided to ask consultants to make recommendations with respect to candidate selection procedures. The recommendation implemented was to create a Nuclear Training Test that would predict the success of a candidate in completing Phase I training and subsequently qualify for reactor operator certification. The mechanics involved in developing and calibrating the Nuclear Training Test are described. An arbitration decision that resulted when a number of International Brotherhood of Electrical Workers union employees filed a grievance alleging that the selection examination was unfair, invalid, not job related, inappropriate, and discriminatorily evaluated is also discussed. The arbitration decision favored the use of the Nuclear Training Test

  9. {sup 14}C urea breath test kit- an evaluation of a compact, cost-effective kit for the detection of H. pylori

    Energy Technology Data Exchange (ETDEWEB)

    Bellon, M.S. [Royal Adelaide Hospital, SA (Australia). Dept of Nuclear Medicine

    1998-03-01

    Full text: Helicobacter pylori infection of the gastric mucosa causes active chronic gastritis and peptic ulceration. Carbon-14 urea breath testing has been well documented in its ability to detect the presence of H. pylori. The aims of this study were to evaluate and refine the test to substantially reduce costs and improve its simplicity, availability and accuracy. We reviewed the results of 138 patients who underwent {sup 14}C urea breath testing for the detection of H. pylori utilising a kit developed at the Royal Adelaide Hospital. Modifications to the standard technique that were assessed included the relevance of buccal cleansing, single sample v multiple sampling, use of alternative CO{sub 2} absorbers and sampling techniques. In those patients with positive biopsy results, a test sensitivity of 100% was achieved. No buccal cleansing is necessary (45% oral contamination without brushing teeth v 41% with). A single breath sample only at 15 min resulted in 100% sensitivity. Alternative (cheaper and safer) CO{sub 2} absorbers such as KOH can be used. Based on these results, modifications to this well documented test have enabled us to substantially reduce costs, improve simplicity and safety and increase accuracy and availability of the test for the detection of Helicobacter pylori.

  10. Prolonged expression of the c-kit receptor in germ cells of intersex fetal testes

    DEFF Research Database (Denmark)

    Rajpert-De Meyts, Ewa; Jørgensen, N; Müller, Jørn

    1996-01-01

    conditions which included 45,X/46,XY mosaicism; androgen insensitivity syndrome; and 46,XY/iso(p)Y mosaicism. Individuals with such disorders of sexual differentiation and Y-chromosome material carry a very high risk of developing testicular neoplasms. Fetal testicular germ cells of the intersex subjects...... expressed Kit at a later developmental age than controls, in which no Kit protein was detectable beyond the 15th week of gestation. This finding may indicate a disturbance of the chronology of germ cell development, or it may suggest a change of the regulation of c-kit expression in subjects with disorders...

  11. Perceived Cost Advantages and Disadvantages of Purchasing HIV Self-Testing Kits among Urban Tanzanian Men: An Inductive Content Analysis.

    Science.gov (United States)

    Jennings, Larissa; Conserve, Donaldson F; Merrill, Jamison; Kajula, Lusajo; Iwelunmor, Juliet; Linnemayr, Sebastian; Maman, Suzanne

    2017-08-01

    Impoverished men have lower rates of facility-based HIV counseling and testing and higher unknown HIV-positive status than women. Economic theory suggests that individuals will obtain an HIV test if anticipated benefits are greater than anticipated costs. Yet, few studies have investigated the range of financial preferences of HIV self-testing (HIVST) among poor men who decline testing or do not test regularly. Twenty-three interviews were conducted to qualitatively assess perceived costs saved and costs incurred from use of HIVST kits in infrequently- or never-tested Tanzanian men. All men were shown an HIVST kit and video. They were then asked about the costs associated with provider-led HIV testing, financial benefits and concerns of HIVST and willingness to pay for HIVST. Data were transcribed, coded and analyzed using inductive content analyses. We then grouped codes into perceived cost advantages and disadvantages and tabulated the range of prices men were willing to pay for a self-test kit. Perceived cost advantages of HIVST were avoidance of spending money to test in facilities, omission of follow-up fees, affordability relative to private clinics, and increased time for earning income and other activities. Men also discussed the imbalance of the financial benefit of accessing free, public HIV testing with the resources spent for transport, purchasing meals away from home and long wait lines. Perceived cost disadvantages of HIVST were prohibitive kit costs, required prior savings to purchase kits, expenditures relating to death and preferences for free provider-performed testing. Men were also concerned about the psychological costs of inaccurate results. HIVST willingness to pay varied among men. Men's decisions to self-test for HIV takes into account expected financial gains and losses. Demand generation for HIVST among men should consider use of low fees or free HIVST, while emphasizing potential savings from reduced travel, clinical costs, or time way

  12. Preappointment testing for BRAF/KIT mutation in advanced melanoma: a model in molecular data delivery for individualized medicine.

    Science.gov (United States)

    Mounajjed, Taofic; Brown, Char L; Stern, Therese K; Bjorheim, Annette M; Bridgeman, Andrew J; Rumilla, Kandelaria M; McWilliams, Robert R; Flotte, Thomas J

    2014-11-01

    The emergence of individualized medicine is driven by developments in precision diagnostics, epitomized by molecular testing. Because treatment decisions are being made based on such molecular data, data management is gaining major importance. Among data management challenges, creating workflow solutions for timely delivery of molecular data has become pivotal. This study aims to design and implement a scalable process that permits preappointment BRAF/KIT mutation analysis in melanoma patients, allowing molecular results necessary for treatment plans to be available before the patient's appointment. Process implementation aims to provide a model for efficient molecular data delivery for individualized medicine. We examined the existing process of BRAF/KIT testing in melanoma patients visiting our institution for oncology consultation. We created 5 working groups, each designing a specific segment of an alternative process that would allow preappointment BRAF/KIT testing and delivery of results. Data were captured and analyzed to evaluate the success of the alternative process. For 1 year, 35 (59%) of 55 patients had prior BRAF/KIT testing. The remaining 20 patients went through the new process of preappointment testing; results were available at the time of appointment for 12 patients (overall preappointment results availability, 85.5%). The overall process averaged 13.4 ± 4.7 days. In conclusion, we describe the successful implementation of a scalable workflow solution that permits preappointment BRAF/KIT mutation analysis and result delivery in melanoma patients. This sets the stage for further applications of this model to other conditions, answering an increasing demand for robust delivery of molecular data for individualized medicine. Copyright © 2014 Elsevier Inc. All rights reserved.

  13. A new field test kit for the rapid determination of diesel fuel in soil

    International Nuclear Information System (INIS)

    Schabron, J.F.; Niss, N.D.; Hart, B.K.; Hart, J.K.

    1995-01-01

    A new test kit is available for evaluating diesel and other fuel contamination in soils. While the Freon extraction/infrared method estimates fuel concentration by measuring aliphatic C-H stretch, approaches designed to replace this such as the immunoassay method and the method involving a Fridel-Crafts alkylation reaction measure the aromatic component of fuel mixtures. Both of these methods measure aromatic content indirectly with visible color development. The new method measures the aromatic components directly with a 254 nm portable field photometer. The method is very simple since it does not involve complicated color development steps, and does not require the use of highly toxic reagents. It involves a 3-minute extraction of soil with a 10:1 ratio of isopropyl alcohol. Prior to extraction, the soil is treated with an agent to minimize the extraction of humic materials which can interfere. The extract solution is passed through a syringe filter and the absorbance is read at 254 nm. The fuel concentration is calculated based on average relative response factors. Alternatively, the actual contaminant fuel can be used as a standard if it is known. The quantitation limit is about 75 mg/kg diesel in soil. The method has been tested with a variety of soils and fuel types

  14. Inventions leading to the development of the diagnostic test kit industry--from the modern pregnancy test to the sandwich assays.

    Science.gov (United States)

    Wide, Leif

    2005-01-01

    The universities are encouraged by the government nowadays to stimulate innovations and also to provide the proper machinery for assisting the protection and commercialisation of innovations. A better understanding of the innovation process may help to create an atmosphere suitable for inventions at the university. Examples can be taken from successful innovations previously made at the university. During the 1960's I made a series of inventions, which ultimately led to the development of the diagnostic test kit industry. The first, which I made as an undergraduate, was a simple and reliable test kit for diagnosis of pregnancy. This was followed by the solid phase radioimmunoassay and a solid phase assay for vitamin B12; next, the dual specific non-competitive sandwich assay and the in-vitro test for diagnosis of allergy, called RAST (Radioallergosorbent test). Organon in Holland with the pregnancy test kit, and Pharmacia in Sweden with test kits for radioimmunoassay, became pioneers among the diagnostic test kit industries. Pharmacia Diagnostics later became one of the leading diagnostic test kit companies in the world and has continued to be so in the field of allergy diagnosis. Each one of these inventions started with a few unique observations leading to a technical development. The pregnancy test as well as the allergy test emerged from the development of assay methods with unique qualities with the subsequent search for appropriate applications. The foreseeing of a commercial value on a future market was a very important step. This was followed by the search for a suitable industry interested to exploit the invention with its new business opportunity i.e. apply for a patent, produce and market the products, which in my case consisted of the necessary reagents and equipments for particular diagnostic tests. Finally, an agreement had to be settled between the entrepreneur and the inventors. This report describes these inventions and particularly discusses some

  15. Analytic laboratory performance of a point of care urine culture kit for diagnosis and antibiotic susceptibility testing.

    Science.gov (United States)

    Bongard, E; Frimodt-Møller, N; Gal, M; Wootton, M; Howe, R; Francis, N; Goossens, H; Butler, C C

    2015-10-01

    Currently available point-of-care (POC) diagnostic tests for managing urinary tract infections (UTIs) in general practice are limited by poor performance characteristics, and laboratory culture generally provides results only after a few days. This laboratory evaluation compared the analytic performance of the POC UK Flexicult(™) (Statens Serum Institut) (SSI) urinary kit for quantification, identification and antibiotic susceptibility testing and routine UK National Health Service (NHS) urine processing to an advanced urine culture method. Two hundred urine samples routinely submitted to the Public Health Wales Microbiology Laboratory were divided and: (1) analysed by routine NHS microbiological tests as per local laboratory standard operating procedures, (2) inoculated onto the UK Flexicult(™) SSI urinary kit and (3) spiral plated onto Colorex Orientation UTI medium (E&O Laboratories Ltd). The results were evaluated between the NHS and Flexicult(™ )methods, and discordant results were compared to the spiral plating method. The UK Flexicult(™) SSI urinary kit was compared to routine NHS culture for identification of a pure or predominant uropathogen at ≥ 10(5) cfu/mL, with a positive discordancy rate of 13.5% and a negative discordancy rate of 3%. The sensitivity and specificity were 86.7% [95% confidence interval (CI) 73.8-93.7] and 82.6% (95% CI 75.8-87.7), respectively. The UK Flexicult(™) SSI urinary kit was comparable to routine NHS urine processing in identifying microbiologically positive UTIs in this laboratory evaluation. However, the number of false-positive samples could lead to over-prescribing of antibiotics in clinical practice. The Flexicult(™) SSI kit could be useful as a POC test for UTIs in primary care but further pragmatic evaluations are necessary.

  16. Cold Leak Tests of LHC Beam Screens

    CERN Document Server

    Collomb-Patton, C; Jenninger, B; Kos, N

    2009-01-01

    In order to guide the high energy proton beams inside its two 27 km long vacuum rings, the Large Hadron Collider (LHC) at CERN, Geneva, makes use of superconducting technology to create the required magnetic fields. More than 4000 beam screens, cooled at 7 20 K, are inserted inside the 1.9 K beam vacuum tubes to intercept beam induced heat loads and to provide dynamic vacuum stability. As extremely high helium leak tightness is required, all beam screens have been leak tested under cold conditions in a dedicated test stand prior to their installation. After describing the beam screen design and its functions, this report focuses on the cold leak test sequence and discusses the results.

  17. Test equality between two binary screening tests with a confirmatory procedure restricted on screen positives.

    Science.gov (United States)

    Lui, Kung-Jong; Chang, Kuang-Chao

    2015-01-01

    In studies of screening accuracy, we may commonly encounter the data in which a confirmatory procedure is administered to only those subjects with screen positives for ethical concerns. We focus our discussion on simultaneously testing equality of sensitivity and specificity between two binary screening tests when only subjects with screen positives receive the confirmatory procedure. We develop four asymptotic test procedures and one exact test procedure. We derive sample size calculation formula for a desired power of detecting a difference at a given nominal [Formula: see text]-level. We employ Monte Carlo simulation to evaluate the performance of these test procedures and the accuracy of the sample size calculation formula developed here in a variety of situations. Finally, we use the data obtained from a study of the prostate-specific-antigen test and digital rectal examination test on 949 Black men to illustrate the practical use of these test procedures and the sample size calculation formula.

  18. Design of test kits for the RF characterization of the PAM antenna of LHCD system for Aditya-upgrade Tokamak

    International Nuclear Information System (INIS)

    Jain, Yogesh M.; Sharma, P.K.; Parmar, P.R.; Ambulkar, K.K.

    2017-01-01

    The Lower Hybrid Current Drive (LHCD) system of the ADITYA-Upgrade tokamak will employ a Passive Active Multijunction (PAM) antenna to launch 250 kW of RF power at 3.7 GHz to drive plasma current non inductively in the tokamak. To evaluate the RF performance of the designed PAM antenna, it is characterized with the help of VNA measurements. The performance of the PAM antenna is mainly decided by the integrated performance of the entire antenna (with a differential phase shift of 270° and equal power distribution between each of the output waveguides) and the performance of mode converter, which transforms input TE 10 mode to TE 30 mode (with a mode purity of 98.5% at the output). This poster thus reports the design and analysis of these testing kits. Also, the test results of PAM antenna obtained by using these test kits would also be presented and discussed in this poster

  19. Benchmarking Tool Kit.

    Science.gov (United States)

    Canadian Health Libraries Association.

    Nine Canadian health libraries participated in a pilot test of the Benchmarking Tool Kit between January and April, 1998. Although the Tool Kit was designed specifically for health libraries, the content and approach are useful to other types of libraries as well. Used to its full potential, benchmarking can provide a common measuring stick to…

  20. QUENCH-LOCA program at KIT and results of the QUENCH-L0 bundle test

    International Nuclear Information System (INIS)

    Stuckert, J.; Grosse, M.; Roessger, C.; Steinbrueck, M.; Walter, M.

    2012-01-01

    of Technology (KIT) in the QUENCH facility. Compared to single-rod experiments, bundle tests have the advantage of studying the mutual interference of rod ballooning among fuel rod simulators as well as the local coolant channel blockages in a more realistic arrangement. The program was started in 2010 with the QUENCH-L0 scoping test used 21 heated rods with as-received Zry-4 claddings. Then advanced claddings (Duplex D4, M5 registered , ZIRLO trademark) will be used. (orig.)

  1. QUENCH-LOCA program at KIT and results of the QUENCH-L0 bundle test

    Energy Technology Data Exchange (ETDEWEB)

    Stuckert, J.; Grosse, M.; Roessger, C.; Steinbrueck, M.; Walter, M. [Karlsruhe Institute of Technology (KIT), Eggenstein-Leopoldshafen (Germany)

    2012-11-01

    Karlsruhe Institute of Technology (KIT) in the QUENCH facility. Compared to single-rod experiments, bundle tests have the advantage of studying the mutual interference of rod ballooning among fuel rod simulators as well as the local coolant channel blockages in a more realistic arrangement. The program was started in 2010 with the QUENCH-L0 scoping test used 21 heated rods with as-received Zry-4 claddings. Then advanced claddings (Duplex D4, M5 {sup registered}, ZIRLO trademark) will be used. (orig.)

  2. Cancer screening tests for small animals.

    Science.gov (United States)

    Schleis, Stephanie E

    2014-09-01

    Cancer is increasingly more common. Several tests for the diagnosis and treatment of cancer in companion animals have been developed. Screening tests discussed include those for lymphoid neoplasia, hemangiosarcoma, and transitional cell carcinoma of the bladder. None of these tests should be used in isolation for diagnosis. Vincristine and doxorubicin are mainstays in the treatment of canine lymphoma. However, it is important and accepted practice to test individuals of predisposed breeds for this mutation before administering these drugs in a lymphoma protocol. Copyright © 2014 Elsevier Inc. All rights reserved.

  3. Preoperative screening: value of previous tests.

    Science.gov (United States)

    Macpherson, D S; Snow, R; Lofgren, R P

    1990-12-15

    To determine the frequency of tests done in the year before elective surgery that might substitute for preoperative screening tests and to determine the frequency of test results that change from a normal value to a value likely to alter perioperative management. Retrospective cohort analysis of computerized laboratory data (complete blood count, sodium, potassium, and creatinine levels, prothrombin time, and partial thromboplastin time). Urban tertiary care Veterans Affairs Hospital. Consecutive sample of 1109 patients who had elective surgery in 1988. At admission, 7549 preoperative tests were done, 47% of which duplicated tests performed in the previous year. Of 3096 previous results that were normal as defined by hospital reference range and done closest to the time of but before admission (median interval, 2 months), 13 (0.4%; 95% CI, 0.2% to 0.7%), repeat values were outside a range considered acceptable for surgery. Most of the abnormalities were predictable from the patient's history, and most were not noted in the medical record. Of 461 previous tests that were abnormal, 78 (17%; CI, 13% to 20%) repeat values at admission were outside a range considered acceptable for surgery (P less than 0.001, frequency of clinically important abnormalities of patients with normal previous results with those with abnormal previous results). Physicians evaluating patients preoperatively could safely substitute the previous test results analyzed in this study for preoperative screening tests if the previous tests are normal and no obvious indication for retesting is present.

  4. [Mass neonatal screening using biological testing].

    Science.gov (United States)

    Ardaillou, R; Le Gall, J-Y

    2007-04-01

    Implementation of a generalized screening program for neonatal diseases obeys precise guidelines. The disease must be severe, recognizable at an early stage, accessible to an effective treatment, detected with a non expansive and widely applicable test and it must represent an important health problem. In case of positive results, treatment or prevention shall be offered immediately and any screening program has to be regularly evaluated. There is in France since 1978 a national screening program that depends on a private association ("Association française pour le dépistage et la prévention des handicaps de l'enfant") and is supervised by the "Caisse nationale d'assurance maladie" and the "Direction Générale de la Sante". Presently, five diseases are included in the screening program: phenylketonuria, hypothyroidism, congenital adrenal hyperplasia, cystic fibrosis and sickle cell disease, the latter only in at risk newborns. Toxoplasmosis represents a particular problem because screening takes place only in children of mothers that have not been controlled during their pregnancy or in case of seroconversion. Neonatal screening of phenylketonuria and hypothyrodism is unanimously recommended. That of congenital adrenal hyperplasia is approved in most countries. The cases of sickle cell disease and cystic fibrosis are more complex because: 1) all the children that carry the mutations are not affected with a severe disease; 2) there is no curative treatment; 3) parents given information are made anxious, sometimes wrongly if the disease is mild or asymptomatic. The supporters of the screening insist on the interest of an early diagnosis which makes longer the life time of these children, the possibility for the parents to utilize prenatal screening in case of a future pregnancy, and the information given to the heterozygous carriers following a familial screening. The question is raised of the extension of neonatal screening to other diseases. This is now

  5. Efficacy of a chairside diagnostic test kit for estimation of C-reactive protein levels in periodontal disease.

    Science.gov (United States)

    Nagarale, Girish; Ravindra, S; Thakur, Srinath; Setty, Swati

    2010-10-01

    C-reactive protein [CRP] levels increase to hundreds of mg/mL within hours following infection. Studies have shown that serum CRP levels were elevated in periodontal disease. However, in all the previous studies, CRP levels were measured by using high-sensitivity CRP assay kits with minimal detection limits of 0.1 to 3 mg/L, which was much below the normal value of 10 mg/L. These high-sensitivity CRP assays need a proper laboratory setup, and these methods cannot be used as a routine chair-side test in the dental office. The purpose of this study was to investigate the serum CRP levels in subjects with periodontal disease by using a rapid chair-side diagnostic test kit with a lower detection limit of 6 mg/L and to compare the CRP levels before and after periodontal therapy. A total of 45 systemically healthy subjects were selected for the study. Subjects were divided into three groups: group A: healthy controls, group B: gingivitis, group C: periodontitis. Serum levels of CRP were determined by using a latex slide agglutination method with commercially available kit with lower detection limit of 6 mg/L. CRP was negative in all the 15 subjects in groups A and B at baseline, 7th and 30th day. CRP was positive only in 2 subjects in Group C at baseline and 7th day. Estimation of serum CRP by using a rapid chair-side diagnostic test kit is not of any significance in subjects with periodontitis.

  6. Dry Kit Development And Clinical Test Of 99mTc-L,L-ECD Radiopharmaceutical For Vrain Perfusion Imaging

    International Nuclear Information System (INIS)

    Kartini, Nani; Sofyan, Rohestri; Rukmini; Iswahyudi

    2000-01-01

    Technetium- 99m ethyl cysteinate dimer ( 99m Tc-L,L-ECD) has been synthesized and formulated based on ligand exchanged reaction with 99mTc-glucoheptonate. Considering the low stability of the dry kit produced, it was fairly necessary to develop the manufacture of L,L-ECD dry kit in order to obtain a more stable one that meet the requirements as brain perfusion imaging radiopharmaceutical. Experiment was done by modifying the packing of dry kit components of the previous formulation. Characteristics of 99m Tc-L,L-ECD produced from this formulation were studied by carrying out the sterility and toxicity test, then followed with clinical test to some volunteers. Evaluation of brain perfusion was done by tomography technique using gamma camera at Nuclear Medicine Installation, Hasan Sadikin Hospital. The modified formulation obtained consist of three components i.e. main ligand L,L-ECD; exchange ligand Ca-glucoheptonate and HaOH. Its stability could reach 8 months at-10 derajat C of storage. Effects of toxicity on mice did not appear. The result of clinical study shows that the radiopharmaceutical was distributed very rapidly in the blood brain circulations and retained in the brain for about one hour. The body scanning indicates that the substance was excreted in the brain for about one hour. The body scanning indicates that the substance was excreted though kidney, liver and spleen. Based on the results obtained the radiopharmaceutical could be promoted to be used for brain perfusion imaging

  7. Performance of rapid tests and algorithms for HIV screening in Abidjan, Ivory Coast.

    Science.gov (United States)

    Loukou, Y G; Cabran, M A; Yessé, Zinzendorf Nanga; Adouko, B M O; Lathro, S J; Agbessi-Kouassi, K B T

    2014-01-01

    Seven rapid diagnosis tests (RDTs) of HIV were evaluated by a panel group who collected serum samples from patients in Abidjan (HIV-1 = 203, HIV-2 = 25, HIV-dual = 25, HIV = 305). Kit performances were recorded after the reference techniques (enzyme-linked immunosorbent assay). The following RDTs showed a sensitivity of 100% and a specificity higher than 99%: Determine, Oraquick, SD Bioline, BCP, and Stat-Pak. These kits were used to establish infection screening strategies. The combination with 2 or 3 of these tests in series or parallel algorithms showed that series combinations with 2 tests (Oraquick and Bioline) and 3 tests (Determine, BCP, and Stat-Pak) gave the best performances (sensitivity, specificity, positive predictive value, and negative predictive value of 100%). However, the combination with 2 tests appeared to be more onerous than the combination with 3 tests. The combination with Determine, BCP, and Stat-Pak tests serving as a tiebreaker could be an alternative to the HIV/AIDS serological screening in Abidjan.

  8. Evaluation of microcystin contamination in blue-green algal dietary supplements using a protein phosphatase inhibition-based test kit.

    Science.gov (United States)

    Marsan, David W; Conrad, Stephen M; Stutts, Whitney L; Parker, Christine H; Deeds, Jonathan R

    2018-03-01

    The cyanobacterium Aphanizomenon flos-aquae (AFA), from Upper-Klamath Lake, Oregon, are used to produce blue-green algal (BGA) dietary supplements. The periodic co-occurrence of hepatotoxin-producing contaminant species prompted the Oregon Health Division to establish a limit of 1 μg/g microcystin (MC) for products sold in Oregon in 1997. At the federal level, the current good manufacturing practice (CGMP) regulations for dietary supplements require manufacturers establish a specification, and test, for limits on contaminants that may adulterate finished products. Despite this, several previous international surveys reported MC in BGA supplements in excess of 1 μg/g. The objectives of this study were (1) identify a reliable, easy to use test kit for the detection of MC in dried BGA materials and (2) use this kit to assess the occurrence of MC contamination in AFA-BGA dietary supplements in the U.S. A commercial protein phosphatase inhibition assay (PPIA), based on the enzyme PP2A, was found to have acceptable relative enzyme inhibition and accuracy for the majority of MC variants tested, including those most commonly identified in commercial samples, making the kit fit for purpose. Using the PPIA kit, 51% (26 of 51) distinct AFA-BGA products had MC ≥0.25 μg/g (the detection limit of the kit), 10 products had MC concentrations between 0.5 and 1.0 μg/g, and 4 products exceeded the limit (1.1-2.8 μg/g). LC-MS/MS confirmed PPIA results ≥0.5 μg/g and determined that MC-LA and MC-LR were the main congeners present. PPIA is a reliable method for the detection of MC contamination in dried BGA dietary supplements produced in the U.S. While the majority of AFA-BGA products contained ≥0.25 μg/g MC, most were at or below 1.0 μg/g, suggesting that manufacturers have adopted this level as a specification in these products; however, variability in recommended serving sizes prevented further analysis of consumer exposure based on the concentrations of MC

  9. Evaluation of microcystin contamination in blue-green algal dietary supplements using a protein phosphatase inhibition-based test kit

    Directory of Open Access Journals (Sweden)

    David W. Marsan

    2018-03-01

    Full Text Available The cyanobacterium Aphanizomenon flos-aquae (AFA, from Upper-Klamath Lake, Oregon, are used to produce blue-green algal (BGA dietary supplements. The periodic co-occurrence of hepatotoxin-producing contaminant species prompted the Oregon Health Division to establish a limit of 1 μg/g microcystin (MC for products sold in Oregon in 1997. At the federal level, the current good manufacturing practice (CGMP regulations for dietary supplements require manufacturers establish a specification, and test, for limits on contaminants that may adulterate finished products. Despite this, several previous international surveys reported MC in BGA supplements in excess of 1 μg/g. The objectives of this study were (1 identify a reliable, easy to use test kit for the detection of MC in dried BGA materials and (2 use this kit to assess the occurrence of MC contamination in AFA-BGA dietary supplements in the U.S. A commercial protein phosphatase inhibition assay (PPIA, based on the enzyme PP2A, was found to have acceptable relative enzyme inhibition and accuracy for the majority of MC variants tested, including those most commonly identified in commercial samples, making the kit fit for purpose. Using the PPIA kit, 51% (26 of 51 distinct AFA-BGA products had MC ≥0.25 μg/g (the detection limit of the kit, 10 products had MC concentrations between 0.5 and 1.0 μg/g, and 4 products exceeded the limit (1.1–2.8 μg/g. LC-MS/MS confirmed PPIA results ≥0.5 μg/g and determined that MC-LA and MC-LR were the main congeners present. PPIA is a reliable method for the detection of MC contamination in dried BGA dietary supplements produced in the U.S. While the majority of AFA-BGA products contained ≥0.25 μg/g MC, most were at or below 1.0 μg/g, suggesting that manufacturers have adopted this level as a specification in these products; however, variability in recommended serving sizes prevented further analysis of consumer exposure based on the concentrations of MC

  10. Preparation of phase I of clinical testing of kit for bleomycin labelling with 57Co

    International Nuclear Information System (INIS)

    Brousil, J.; Svihovcova, P.; Seblova, J.; Raban, P.

    1986-01-01

    Experience is described gained in preclinical trials with a kit for bleomycin labelling with 57 Co, of original manufacture. The 57 Co-labelled bleomycin shows a positive tumor imaging potential. As against other labelled bleomycins described in the literature, it best meets the requirements of imaging tumors in the highest possible number of tissues and of good differentiation of tumors from the adjacent tissues. The three-component kit uses a phosphate buffer which makes it more suitable for i.v. administration and significantly increases bleomycin stability. The kit was found to show advantages over previously described radiopharmaceuticals of this type in that that it can quickly be reconstituted immediately prior to the application and that it is significantly cheaper to use, namely 140-fold cheaper than most other similar radiopharmaceuticals. Its disadvantage, i.e., the long half-life is balanced with a short biological half-life; within 24 hours following application 80 to 90% of the applied activity was found to be excreted from the organism. The short biological half-life is also beneficial for the patient in that the radiation load of the patient is 10 times lower than in the application of 67 Ga. (L.O.)

  11. Nationwide study of factors associated with public’s willingness to use home self-test kit for dengue fever in Malaysia

    Directory of Open Access Journals (Sweden)

    Li Ping Wong

    2016-08-01

    Full Text Available Abstract Background As there is no specific treatment for dengue, early detection and access to proper treatment may lower dengue fatality. Therefore, having new techniques for the early detection of dengue fever, such as the use of dengue test kit, is vitally important. The aims of the study were: 1 identify factors associated with acceptance of a home self-test kit for dengue fever if the dengue test is available to the public and 2 find out the characteristics of the test kits that influence the use of the dengue test kit. Methods A national telephone survey was carried out with 2,512 individuals of the Malaysian public aged 18–60 years old. Individuals were contacted by random digit dialling covering the whole of Malaysia from February 2012 to June 2013. Results From 2,512 participants, 6.1 % reported to have heard of the availability of the dengue home test kit and of these, 44.8 % expressed their intention to use the test kit if it was available. Multivariate logistic regressions indicated that participants with primary (OR: 0.65; 95 % CI: 0.43–0.89; p = 0.02, vs. tertiary educational level and secondary educational levels (OR: 0.73; 95 % CI: 0.57–0.90; p = 0.01, vs. tertiary educational level were less likely than participants with a tertiary educational level to use a home self-testing dengue kit for dengue if the kit was available. Participants with lower perceived barriers to dengue prevention (level of barriers 0–5 were less likely (OR: 0.67, 95 % CI: 0.53–0.85, p < 0.001, vs. higher perceived barriers to use a home self-testing dengue kit for dengue if the kit was available compared to those with higher perceived barriers to dengue prevention (level of barriers 6-10. Participants with a lower total dengue fever knowledge score (range 0–22 were also less likely to use a home self-testing dengue kit for dengue if the kit was available (OR: 0.75; 95 % CI: 0.61–0.91, p = 0.001, vs. higher total dengue

  12. Development of RIA kits for tumor-markers monitoring

    International Nuclear Information System (INIS)

    Suprarop, P.

    1997-01-01

    All reagents for tumor markers assays are imported from various manufacturers mainly CIS bio international. The average cost of these reagents is ranged from 80-150 bath/test (2-4 dollars test). The screening test for cancers could not be done especially in other regions of Thailand whose budgets and resources are so limited. If the reagents are made locally, many laboratories can perform the tests and use as primary diagnosis, screening or monitor the course of the disease following treatment. In addition, these reagents could help clinicians and give complementary information on the tumor status to improve quality of life in Thailand. Research objectives include: 1. Development of IRMA reagent kits suitable for diagnosing staging and monitoring prostrate and breast cancer. 2. Transfer of technology and reagent kits to relevant laboratories in Thailand. 3. Routine distribution of the reagents kits to the end users

  13. A new paradigm for Aedes spp. surveillance using gravid ovipositing sticky trap and NS1 antigen test kit.

    Science.gov (United States)

    Lau, Sai Ming; Chua, Tock H; Sulaiman, Wan-Yussof; Joanne, Sylvia; Lim, Yvonne Ai-Lian; Sekaran, Shamala Devi; Chinna, Karuthan; Venugopalan, Balan; Vythilingam, Indra

    2017-03-21

    Dengue remains a serious public health problem in Southeast Asia and has increased 37-fold in Malaysia compared to decades ago. New strategies are urgently needed for early detection and control of dengue epidemics. We conducted a two year study in a high human density dengue-endemic urban area in Selangor, where Gravid Ovipositing Sticky (GOS) traps were set up to capture adult Aedes spp. mosquitoes. All Aedes mosquitoes were tested using the NS1 dengue antigen test kit. All dengue cases from the study site notified to the State Health Department were recorded. Weekly microclimatic temperature, relative humidity (RH) and rainfall were monitored. Aedes aegypti was the predominant mosquito (95.6%) caught in GOS traps and 23% (43/187 pools of 5 mosquitoes each) were found to be positive for dengue using the NS1 antigen kit. Confirmed cases of dengue were observed with a lag of one week after positive Ae. aegypti were detected. Aedes aegypti density as analysed by distributed lag non-linear models, will increase lag of 2-3 weeks for temperature increase from 28 to 30 °C; and lag of three weeks for increased rainfall. Proactive strategy is needed for dengue vector surveillance programme. One method would be to use the GOS trap which is simple to setup, cost effective (below USD 1 per trap) and environmental friendly (i.e. use recyclable plastic materials) to capture Ae. aegypti followed by a rapid method of detecting of dengue virus using the NS1 dengue antigen kit. Control measures should be initiated when positive mosquitoes are detected.

  14. Collimator kit

    International Nuclear Information System (INIS)

    Jonker, R.R.

    1976-01-01

    A collimator kit having a number of parts which may be assembled in various combinations to provide focusing collimators with different performance characteristics for radioisotope imaging apparatus is described

  15. 42 CFR 410.17 - Cardiovascular disease screening tests.

    Science.gov (United States)

    2010-10-01

    ... 42 Public Health 2 2010-10-01 2010-10-01 false Cardiovascular disease screening tests. 410.17... § 410.17 Cardiovascular disease screening tests. (a) Definition. For purposes of this subpart, the... Part B covers cardiovascular disease screening tests when ordered by the physician who is treating the...

  16. 21 CFR 866.2420 - Oxidase screening test for gonorrhea.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Oxidase screening test for gonorrhea. 866.2420... screening test for gonorrhea. (a) Identification. An oxidase screening test for gonorrhea is an in vitro... of gonorrhea. (b) Classification. Class III (premarket approval) (transitional device). (c) Date PMA...

  17. [Mokken scaling of the Cognitive Screening Test].

    Science.gov (United States)

    Diesfeldt, H F A

    2009-10-01

    The Cognitive Screening Test (CST) is a twenty-item orientation questionnaire in Dutch, that is commonly used to evaluate cognitive impairment. This study applied Mokken Scale Analysis, a non-parametric set of techniques derived from item response theory (IRT), to CST-data of 466 consecutive participants in psychogeriatric day care. The full item set and the standard short version of fourteen items both met the assumptions of the monotone homogeneity model, with scalability coefficient H = 0.39, which is considered weak. In order to select items that would fulfil the assumption of invariant item ordering or the double monotonicity model, the subjects were randomly partitioned into a training set (50% of the sample) and a test set (the remaining half). By means of an automated item selection eleven items were found to measure one latent trait, with H = 0.67 and item H coefficients larger than 0.51. Cross-validation of the item analysis in the remaining half of the subjects gave comparable values (H = 0.66; item H coefficients larger than 0.56). The selected items involve year, place of residence, birth date, the monarch's and prime minister's names, and their predecessors. Applying optimal discriminant analysis (ODA) it was found that the full set of twenty CST items performed best in distinguishing two predefined groups of patients of lower or higher cognitive ability, as established by an independent criterion derived from the Amsterdam Dementia Screening Test. The chance corrected predictive value or prognostic utility was 47.5% for the full item set, 45.2% for the fourteen items of the standard short version of the CST, and 46.1% for the homogeneous, unidimensional set of selected eleven items. The results of the item analysis support the application of the CST in cognitive assessment, and revealed a more reliable 'short' version of the CST than the standard short version (CST14).

  18. Ex post and ex ante willingness to pay (WTP) for the ICT Malaria Pf/Pv test kit in Myanmar.

    Science.gov (United States)

    Cho-Min-Naing; Lertmaharit, S; Kamol-Ratanakul, P; Saul, A J

    2000-03-01

    Willingness to pay (WTP) for the ICT Malaria Pf/Pv test kit was assessed by the contingent valuation method using a bidding game approach in two villages in Myanmar. Kankone (KK) village has a rural health center (RHC) and Yae-Aye-Sann (YAS) is serviced by community health worker (CHW). The objectives were to assess WTP for the ICT Malaria Pf/Pv test kit and to determine factors affecting the WTP. In both villages WTP was assessed in two different conditions, ex post and ex ante. The ex post WTP was assessed at an RHC in the KK village and at the residence of a CHW in the YAS village on patients immediately following diagnosis of malaria. The ex ante WTP was assessed by household interviews in both villages on people with a prior history of malaria. Ordinary least squares (OLS) multiple regression analysis was used to analyze factors affecting WTP. The WTP was higher in ex post conditions than ex ante in both villages. WTP was significantly positively associated with the average monthly income of the respondents and severity of illness in both ex post and ex ante conditions (p WTP (p < 0.05) in the ex post condition in the RHC survey in KK village.

  19. Mechanized toxicological serum tests in screening hospitalized patients.

    Science.gov (United States)

    Hallbach, J; Guder, W G

    1991-09-01

    provided by the EMIT tox test kits. As a consequence, decision limits for all three group tests in serum were lowered to near the detection limit: (table: see text) For quantitative tests the lower limits of quantification were: (table: see text) The working reagents were stable for at least 14 days at 4-8 degrees C. Calibration curves were stable over the expiration period of reconstituted original reagents (6-12 weeks), also when working reagents were prepared in aliquots from stored reconstituted reagents. Application of the newly adapted programme to serum samples of nearly two hundred patients showed it to be suitable for screening patients in which intoxication is suspected or needs to be excluded.

  20. LANL12-RS-108J Report on Device Modeler Testing of the Device Modeler Tool Kit. DMTK in FY14

    Energy Technology Data Exchange (ETDEWEB)

    Temple, Brian Allen [Los Alamos National Laboratory (LANL), Los Alamos, NM (United States); Pimentel, David A. [Los Alamos National Laboratory (LANL), Los Alamos, NM (United States)

    2014-09-28

    This document covers the various testing and modifications of the Device Modeler Tool Kit (DMTK) for project LANL12-RS-108J in FY14. The testing has been comprised of different device modelers and trainees for device modeling using DMTK on the secure network for a few test problems. Most of these problems have been synthetic data problems. There has been a local secure network training drill where one of the trainees has used DMTK for real data. DMTK has also been used on a laptop for a deployed real data training drill. Once DMTK gets into the home team, it will be used for more training drills (TDs) which will contain real data in the future.

  1. eTEST: Developing a Smart Home HIV Testing Kit that Enables Active, Real-Time Follow-Up and Referral After Testing.

    Science.gov (United States)

    Wray, Tyler; Chan, Philip A; Simpanen, Erik; Operario, Don

    2017-05-08

    Men who have sex with men (MSM) are the group at highest risk for contracting human immunodeficiency virus (HIV) in the United States, but many do not test as frequently as recommended. Home-based self-testing (HBST) for HIV holds promise for promoting regular testing among these individuals, but currently available HBSTs have limited follow-up options, providing only a 1-800 number that participants can call. Failure to actively conduct follow-up counseling and referrals after HBST use could result in delays in seeking confirmatory testing and care among users receiving reactive (preliminary positive) test results. HBST also fails to connect users who test negative with other prevention services that can reduce their future risk for HIV. The aim of our study was to use qualitative research methods with high-risk MSM to inform development of a "smart" HBST kit. The kit utilizes existing Internet-of-Things (IoT) technologies to monitor HBST use in real-time and enable delivery of timely, active follow-up counseling and referrals over the phone. In phase 1, individual interviews (n=10) explored how participants might use HBST and their views and preferences for conducting counseling and referral after HBST. Based on these perspectives, we developed a smartphone app (iOS, Android) that uses data from light sensors on Bluetooth low energy (BLE) beacons to monitor when HBST kits are opened, facilitating timely follow-up phone contact with users. In phase 2, a usability study conducted among high-risk MSM (n=10) examined the acceptability and feasibility of this system and provided user perspectives after using the system along with HBST. Phase 1 themes suggested that MSM preferred HBST, that most thought active follow-up after HBST would be valuable, and that doing so over the phone within 24 h after testing was preferable. Phase 2 results showed that the eTEST system successfully detected HBST use in nearly all cases. Participant perspectives also suggested that the

  2. Information contained within the large scale gas injection test (Lasgit) dataset exposed using a bespoke data analysis tool-kit

    International Nuclear Information System (INIS)

    Bennett, D.P.; Thomas, H.R.; Cuss, R.J.; Harrington, J.F.; Vardon, P.J.

    2012-01-01

    Document available in extended abstract form only. The Large Scale Gas Injection Test (Lasgit) is a field scale experiment run by the British Geological Survey (BGS) and is located approximately 420 m underground at SKB's Aespoe Hard Rock Laboratory (HRL) in Sweden. It has been designed to study the impact on safety of gas build up within a KBS-3V concept high level radioactive waste repository. Lasgit has been in almost continuous operation for approximately seven years and is still underway. An analysis of the dataset arising from the Lasgit experiment with particular attention to the smaller scale features and phenomenon recorded has been undertaken in parallel to the macro scale analysis performed by the BGS. Lasgit is a highly instrumented, frequently sampled and long-lived experiment leading to a substantial dataset containing in excess of 14.7 million datum points. The data is anticipated to include a wealth of information, including information regarding overall processes as well as smaller scale or 'second order' features. Due to the size of the dataset coupled with the detailed analysis of the dataset required and the reduction in subjectivity associated with measurement compared to observation, computational analysis is essential. Moreover, due to the length of operation and complexity of experimental activity, the Lasgit dataset is not typically suited to 'out of the box' time series analysis algorithms. In particular, the features that are not suited to standard algorithms include non-uniformities due to (deliberate) changes in sample rate at various points in the experimental history and missing data due to hardware malfunction/failure causing interruption of logging cycles. To address these features a computational tool-kit capable of performing an Exploratory Data Analysis (EDA) on long-term, large-scale datasets with non-uniformities has been developed. Particular tool-kit abilities include: the parameterization of signal variation in the dataset

  3. Revisions of the Fish Invasiveness Screening Kit (FISK) for its application in warmer climatic zones, with particular reference to peninsular Florida.

    Science.gov (United States)

    Lawson, Larry L; Hill, Jeffrey E; Vilizzi, Lorenzo; Hardin, Scott; Copp, Gordon H

    2013-08-01

    The initial version (v1) of the Fish Invasiveness Scoring Kit (FISK) was adapted from the Weed Risk Assessment of Pheloung, Williams, and Halloy to assess the potential invasiveness of nonnative freshwater fishes in the United Kingdom. Published applications of FISK v1 have been primarily in temperate-zone countries (Belgium, Belarus, and Japan), so the specificity of this screening tool to that climatic zone was not noted until attempts were made to apply it in peninsular Florida. To remedy this shortcoming, the questions and guidance notes of FISK v1 were reviewed and revised to improve clarity and extend its applicability to broader climatic regions, resulting in changes to 36 of the 49 questions. In addition, upgrades were made to the software architecture of FISK to improve overall computational speed as well as graphical user interface flexibility and friendliness. We demonstrate the process of screening a fish species using FISK v2 in a realistic management scenario by assessing the Barcoo grunter Scortum barcoo (Terapontidae), a species whose management concerns are related to its potential use for aquaponics in Florida. The FISK v2 screening of Barcoo grunter placed the species into the lower range of medium risk (score = 5), suggesting it is a permissible species for use in Florida under current nonnative species regulations. Screening of the Barcoo grunter illustrates the usefulness of FISK v2 as a proactive tool serving to inform risk management decisions, but the low level of confidence associated with the assessment highlighted a dearth of critical information on this species. © 2012 Society for Risk Analysis.

  4. Breast, prostate, and thyroid cancer screening tests and overdiagnosis.

    Science.gov (United States)

    Jung, Minsoo

    The purpose of this study was to examine overdiagnosis and overtreatment related to cancer screening and to review relevant reports and studies. A comprehensive search of peer-reviewed and gray literature was conducted for relevant studies published between January 2000 and December 2015 reporting breast, prostate, and thyroid cancer screening tests and overdiagnosis. This study revealed no dichotomy on where screening would lower risk or cause overdiagnosis and overtreatment. Many screening tests did both, that is, at population level, there were both benefit (decreased disease-specific mortality) and harm (overdiagnosis and overtreatment). Therefore, we need to consider a balanced argument with citations for the potential benefits of screening along with the harms associated with screening. Although the benefits and harms can only be tested through randomized trials, important data from cohort studies, diagnostic accuracy studies, and modeling work can help define the extent of benefits and harms in the population. The health care cycle that prompt patients to undergo periodic screening tests is self-reinforcing. In most developed countries, screening test recommendations encourage periodic testing. Therefore, patients are continuing their screening. It is necessary for patients to become wise consumers of screening tests and make decisions with their physicians regarding further testing and treatments. Copyright © 2017 Elsevier Inc. All rights reserved.

  5. Correlates of requesting home HIV self-testing kits on online social networks among African-American and Latino men who have sex with men.

    Science.gov (United States)

    Chiu, ChingChe J; Young, Sean D

    2016-01-01

    High levels of HIV stigma are one of the main difficulties in engaging African-American and Latino men who have sex with men (MSM) in HIV testing. The availability of home HIV test and the possibility of self-testing in private may improve uptake and counteract stigma. This paper sought to determine the correlates of requesting home HIV test kits among a sample of MSM social media users. The odds of participants requesting a test kit were significantly associated with using social networks to seek sexual partners (aOR: 2.47, 95% CI: 1.07-6.06) and thinking it is easier to use social networks for seeking sexual partners (1.87, 1.2-3.12), uncertain HIV status (4.29, 1.37-14.4), and having sex under the influence of alcohol (2.46, 1.06-5.77). Participants who had not been tested for more than 6 months were more likely to request a test kit than those who were tested in the past 6 months (2.53, 1.02-6.37). Participants who frequently talked to others about having sex with men online were less likely to request a test kit (0.73, 0.56-0.92). By reaching people over social media and offering them access to test kits, we were able to reach at-risk individuals who were uncertain about their HIV status and had not been regularly tested. The findings of the study will help to inform future HIV testing interventions.

  6. Development of a computer-based automated pure tone hearing screening device: a preliminary clinical trial.

    Science.gov (United States)

    Gan, Kok Beng; Azeez, Dhifaf; Umat, Cila; Ali, Mohd Alauddin Mohd; Wahab, Noor Alaudin Abdul; Mukari, Siti Zamratol Mai-Sarah

    2012-10-01

    Hearing screening is important for the early detection of hearing loss. The requirements of specialized equipment, skilled personnel, and quiet environments for valid screening results limit its application in schools and health clinics. This study aimed to develop an automated hearing screening kit (auto-kit) with the capability of realtime noise level monitoring to ensure that the screening is performed in an environment that conforms to the standard. The auto-kit consists of a laptop, a 24-bit resolution sound card, headphones, a microphone, and a graphical user interface, which is calibrated according to the American National Standards Institute S3.6-2004 standard. The auto-kit can present four test tones (500, 1000, 2000, and 4000 Hz) at 25 or 40 dB HL screening cut-off level. The clinical results at 40 dB HL screening cut-off level showed that the auto-kit has a sensitivity of 92.5% and a specificity of 75.0%. Because the 500 Hz test tone is not included in the standard hearing screening procedure, it can be excluded from the auto-kit test procedure. The exclusion of 500 Hz test tone improved the specificity of the auto-kit from 75.0% to 92.3%, which suggests that the auto-kit could be a valid hearing screening device. In conclusion, the auto-kit may be a valuable hearing screening tool, especially in countries where resources are limited.

  7. Evaluation of the KEMRI Hep-cell II test kit for detection of hepatitis B ...

    African Journals Online (AJOL)

    To evaluate the Hep-cell II test, blood samples were collected from blood donors and processed for detection of HBsAg using Hep-cell II based on the test principle and procedure outlined by the manufacturer. ELISA Axsym HBsAg test was used as golden standard. Of the 400 samples tested, 287 (71.8%) were positive by ...

  8. Coanda hydro intake screen testing and evaluation

    Energy Technology Data Exchange (ETDEWEB)

    Howarth, J.

    2001-07-01

    The objective of this project has been to evaluate the effectiveness, suitability and cost benefit of the Aquashear Coanda effect, maintenance free intake screen for use in small hydro system intakes. (author)

  9. Self-sampling kits to increase HIV testing among black Africans in the UK: the HAUS mixed-methods study.

    Science.gov (United States)

    Seguin, Maureen; Dodds, Catherine; Mugweni, Esther; McDaid, Lisa; Flowers, Paul; Wayal, Sonali; Zomer, Ella; Weatherburn, Peter; Fakoya, Ibidun; Hartney, Thomas; McDonagh, Lorraine; Hunter, Rachael; Young, Ingrid; Khan, Shabana; Freemantle, Nick; Chwaula, Jabulani; Sachikonye, Memory; Anderson, Jane; Singh, Surinder; Nastouli, Eleni; Rait, Greta; Burns, Fiona

    2018-04-01

    Timely diagnosis of human immunodeficiency virus (HIV) enables access to antiretroviral treatment, which reduces mortality, morbidity and further transmission in people living with HIV. In the UK, late diagnosis among black African people persists. Novel methods to enhance HIV testing in this population are needed. To develop a self-sampling kit (SSK) intervention to increase HIV testing among black Africans, using existing community and health-care settings (stage 1) and to assess the feasibility for a Phase III evaluation (stage 2). A two-stage, mixed-methods design. Stage 1 involved a systematic literature review, focus groups and interviews with key stakeholders and black Africans. Data obtained provided the theoretical base for intervention development and operationalisation. Stage 2 was a prospective, non-randomised study of a provider-initiated, HIV SSK distribution intervention targeted at black Africans. The intervention was assessed for cost-effectiveness. A process evaluation explored feasibility, acceptability and fidelity. Twelve general practices and three community settings in London. HIV SSK return rate. Stage 1 - the systematic review revealed support for HIV SSKs, but with scant evidence on their use and clinical effectiveness among black Africans. Although the qualitative findings supported SSK distribution in settings already used by black Africans, concerns were raised about the complexity of the SSK and the acceptability of targeting. These findings were used to develop a theoretically informed intervention. Stage 2 - of the 349 eligible people approached, 125 (35.8%) agreed to participate. Data from 119 were included in the analysis; 54.5% (65/119) of those who took a kit returned a sample; 83.1% of tests returned were HIV negative; and 16.9% were not processed, because of insufficient samples. Process evaluation showed the time pressures of the research process to be a significant barrier to feasibility. Other major barriers were

  10. Core Flight System Satellite Starter Kit

    Data.gov (United States)

    National Aeronautics and Space Administration — The Core Flight System Satellite Starter Kit (cFS Kit) will allow a small satellite or CubeSat developer to rapidly develop, deploy, test, and operate flight...

  11. Clinical evaluation of thyrotropin-releasing hormone (TRH) test with a sensitive immunoradiometric thyrotropin (TSH) assay kit

    International Nuclear Information System (INIS)

    Nakamura, Saeko; Demura, Reiko; Yamanaka, Yukako; Ishiwatari, Naoko; Jibiki, Kazuko; Odagiri, Emi; Demura, Hiroshi

    1987-01-01

    Thyrotropin-releasing hormone (TRH) test was performed using a commercially available immunoradiometric thyrotropin (TSH) assay kit (RIA-gnost hTSH) in patients with endocrine diseases. The basal serum concentration of TSH ranged from 0.2 to 2.9 μU/ml in healthy subjects. The values for endocrine diseases, except for Graves' disease, were almost within the normal range. A significant increase in TSH values caused by TRH test was observed in females compared with males (4.4 - 24.7 μU/ml vs 4.1 - 12.3 μU/ml). In cases of Graves' disease, there was a good correlation between the basal TSH value and the response of TSH to TRH. However, in the other endocrine diseases, including acromegaly, prolactinoma, anorexia nervosa, Cushing syndrome, and hypopituitarism, the response of TSH to TRH did not necessarily correlated with the basal TSH value. TRH test would be of value in elucidating pathophysiologic features, as well as in accurately diagnosing secretion reserve of TSH. (Namekawa, K.)

  12. Clinical evaluation of thyrotropin-releasing hormone (TRH) test with a sensitive immunoradiometric thyrotropin (TSH) assay kit

    Energy Technology Data Exchange (ETDEWEB)

    Nakamura, Saeko; Demura, Reiko; Yamanaka, Yukako; Ishiwatari, Naoko; Jibiki, Kazuko; Odagiri, Emi; Demura, Hiroshi

    1987-10-01

    Thyrotropin-releasing hormone (TRH) test was performed using a commercially available immunoradiometric thyrotropin (TSH) assay kit (RIA-gnost hTSH) in patients with endocrine diseases. The basal serum concentration of TSH ranged from 0.2 to 2.9 ..mu..U/ml in healthy subjects. The values for endocrine diseases, except for Graves' disease, were almost within the normal range. A significant increase in TSH values caused by TRH test was observed in females compared with males (4.4 - 24.7 ..mu..U/ml vs 4.1 - 12.3 ..mu..U/ml). In cases of Graves' disease, there was a good correlation between the basal TSH value and the response of TSH to TRH. However, in the other endocrine diseases, including acromegaly, prolactinoma, anorexia nervosa, Cushing syndrome, and hypopituitarism, the response of TSH to TRH did not necessarily correlated with the basal TSH value. TRH test would be of value in elucidating pathophysiologic features, as well as in accurately diagnosing secretion reserve of TSH. (Namekawa, K.).

  13. Screening for gestational diabetes: examining a breakfast meal test ...

    African Journals Online (AJOL)

    Objective: This study was performed to analyse the carbohydrate quantity of the non-standardised breakfast meal test consumed as part of a screening test for gestational diabetes. Design: A prospective descriptive design was utilised. Setting: Screening for gestational diabetes was performed in the High-Risk Antenatal ...

  14. Evaluation of the HB&L carbapenemase and extended spectrum beta lactamase-AmpC automated screening kits for the rapid detection of resistant Enterobacteriaceae in rectal swabs

    Directory of Open Access Journals (Sweden)

    Sara Marani

    2017-03-01

    Full Text Available Background. In the past two decades, a rapid increase of infections due to multidrug-resistant Enterobacteriaceae was reported worldwide, including in Italy. These bacteria express genes encoding for extended-spectrum β-lactamases (ESBL or bear a plasmid-mediated AmpC that induce phenotypically a resistance to the last-generation cephalosporins; even more worrying is the rapid increase of Enterobacteriaceae carrying genes conferring resistance to carbapenems (CPE. Materials and methods. The gut may serve as reservoir for these antibiotic drug-resistant bacteria: as a consequence, the rapid detection of drug resistant Enterobacteriaceae from rectal swabs is an important tool to identify rectal carriage of resistant bacteria. This procedure is the basic tool to successfully implement the infection control measures in the hospital wards. The study evaluated the capability of the HB&L ESBL/AmpC and CARBAPENEMASE screening kit (Alifax, Padua, Italy to rapidly identify the drug resistant enterobacteriaceae from rectal swabs: the performance was compared with the conventional method. Results and conclusions. The overall agreement was very good (91% for the detection of ESBL-AmpC, and 96.2% for the identification of CPE; this method is thus an efficient tool to quickly report positive multidrug resistant bacteria in rectal swabs.

  15. Comparison of three commercial fecal calprotectin ELISA test kits used in patients with Inflammatory Bowel Disease

    DEFF Research Database (Denmark)

    Mirsepasi-Lauridsen, Hengameh Chloé; Bachmann Holmetoft, Ulla; Halkjær, Sofie Ingdam

    2016-01-01

    OBJECTIVE: Fecal calprotectin is a noninvasive marker of intestinal inflammation used to distinguish between functional and organic bowel diseases and to evaluate disease activity among patients with Inflammatory Bowel Disease (IBD). The goal of this study was to compare three different ELISA tests...... and 18 to 67 years, respectively. Disease activity in the patients was established using the following clinical activity indices: the Simple Clinical Colitis Activity Index (SCCAI), the Harvey Bradshaw Index (HBI) and the Modified Pouchitis Disease Activity Index (MPDAI). Three ELISA calprotectin tests...... (EK-CAL, CALPRO and HK325) were performed on fecal specimens and results compared. RESULTS: The CALPRO calprotectin ELISA test was shown to have the best specificity of 96% compared to the HK325 and the EK-CAL calprotectin ELISA tests with 28% specificity and 74% specificity, respectively...

  16. Cervical Cancer Screening with HPV Test

    Centers for Disease Control (CDC) Podcasts

    Dr. Stewart Massad, a professor in the Division of Gynecologic Oncology at Washington University in Saint Louis and a board member of the American Society for Colposcopy and Cervical Cancer Prevention (ASCCP), talks about cotesting with human papillomavirus (HPV) as part of a cervical cancer screening program.

  17. Evaluation of dengue NS1 antigen rapid tests and ELISA kits using clinical samples.

    Directory of Open Access Journals (Sweden)

    Subhamoy Pal

    Full Text Available Early diagnosis of dengue virus (DENV infection can improve clinical outcomes by ensuring close follow-up, initiating appropriate supportive therapies and raising awareness to the potential of hemorrhage or shock. Non-structural glycoprotein-1 (NS1 has proven to be a useful biomarker for early diagnosis of dengue. A number of rapid diagnostic tests (RDTs and enzyme-linked immunosorbent assays (ELISAs targeting NS1 antigen (Ag are now commercially available. Here we evaluated these tests using a well-characterized panel of clinical samples to determine their effectiveness for early diagnosis.Retrospective samples from South America were used to evaluate the following tests: (i "Dengue NS1 Ag STRIP" and (ii "Platelia Dengue NS1 Ag ELISA" (Bio-Rad, France, (iii "Dengue NS1 Detect Rapid Test (1st Generation" and (iv "DENV Detect NS1 ELISA" (InBios International, United States, (v "Panbio Dengue Early Rapid (1st generation" (vi "Panbio Dengue Early ELISA (2nd generation" and (vii "SD Bioline Dengue NS1 Ag Rapid Test" (Alere, United States. Overall, the sensitivity of the RDTs ranged from 71.9%-79.1% while the sensitivity of the ELISAs varied between 85.6-95.9%, using virus isolation as the reference method. Most tests had lower sensitivity for DENV-4 relative to the other three serotypes, were less sensitive in detecting secondary infections, and appeared to be most sensitive on Day 3-4 post symptom onset. The specificity of all evaluated tests ranged from 95%-100%.ELISAs had greater overall sensitivity than RDTs. In conjunction with other parameters, the performance data can help determine which dengue diagnostics should be used during the first few days of illness, when the patients are most likely to present to a clinic seeking care.

  18. '. . . if you bring the kit home, you [can] get time and test together with your partner': Pregnant women and male partners' perceptions regarding female partner-delivered HIV self-testing in Uganda - A qualitative study.

    Science.gov (United States)

    Matovu, Joseph Kb; Buregyeya, Esther; Arinaitwe, Jim; Wanyenze, Rhoda K

    2017-11-01

    In 2015, the World Health Organization reported that more than 60 million people were tested for HIV in 122 low- and middle-income countries between 2010 and 2014. Despite this level of progress, over 40% of people living with HIV remain unaware of their HIV status. This calls for innovative approaches to improve uptake of HIV testing services, including use of HIV self-test (HIVST) kits. We conducted a cross-sectional, qualitative study to assess pregnant women and their male partners' perceptions regarding female partner-delivered HIVST kits. This study was conducted at two health facilities in Central Uganda between November and December 2015. Data were collected on pregnant women's willingness to take HIVST kits to their male partners and other household members using eight focus group discussions and 30 in-depth interviews. Data were analyzed following a thematic framework approach. Overall, pregnant women were willing to take HIVST kits to their partners and other household members, with the exception of their cowives. Male partners were willing to use HIVST kits brought by their female partners. Our findings suggest that secondary distribution of HIVST kits through female partners is acceptable and has the potential to improve male partner and household-member HIV testing.

  19. Effect of the presence of two commercial adsorbents in animal feed on Aflatoxin B1 determination by ELISA kit test

    Directory of Open Access Journals (Sweden)

    Francesco Masoero

    2010-01-01

    Full Text Available A rapid AFB1 detection method by ELISA kit test was used on feedstuff samples, and compared to an HPLC method, to verify if the presence of clay-adsorbent (SA could cause erroneous quantification of the toxin. Samples were obtained using two AFB1-contaminated feedstuffs (7.92 and 17.58 µg/kg for low and high contaminated feeds; LC and HC respectively, added either one of two commercial SAs (Atox® and Myco AD and three different inclusion doses (0, 10 and 20 g/kg, respectively for CTR, 1% and 2% doses. The HPLC and ELISA data were compared in CTR samples with a paired t-test. The AFB1 recoveries, performed with ELISA, were analysed as a completely randomized design using a 2×2×3 factorial arrangement. The ELISA method tended to underestimate the AFB1 concentrations with respect to the HPLC method, both in HC (P=0.050 and in LC (P<0.001 feedstuffs. A more drastic reduction (P<0.001 was observed when SAs were included in the two feedstuffs. In particular, Atox® determined an AFB1 recovery of 15,5% in HC and 7,6% in LC (1% dose and of 11,1% in HC and 8,4% in LC (2% dose. Less severe penalisation were observed when Myco AD was added to feeds.

  20. Evaluation of the BACTEC MGIT 960 SL DST Kit and the GenoType MTBDRsl Test for Detecting Extensively Drug-resistant Tuberculosis Cases.

    Science.gov (United States)

    Tekin, Kemal; Albay, Ali; Simsek, Hulya; Sig, Ali Korhan; Guney, Mustafa

    2017-10-01

    The present study aimed to evaluate the performances of the BACTEC MGIT 960 SL DST kit and the GenoType MTBDRsl test for detecting second-line antituberculosis drug resistance in Multidrug-resistant TB (MDR-TB) cases. Forty-six MDR-TB strains were studied. Second-line antituberculosis drug resistances were detected using the BACTEC MGIT 960 SL DST kit and the GenoType MTBDRsl test. The Middlebrook 7H10 agar proportion method was used as the reference test. The sensitivity and specificity values for the BACTEC MGIT 960 SL DST kit were both 100% for amikacin, kanamycin, capreomycin (4 µg/mL), and ofloxacin; 100% and 95.3%, respectively, for capreomycin (10 µg/mL); and 85.7% and 100%, respectively, for moxifloxacin (0.5 µg/mL). The sensitivity and specificity values for the GenoType MTBDRsl test to detect fluoroquinolone and aminoglycoside/cyclic peptide resistance were 88.9% and 100%, respectively, for ofloxacin and 85.7% and 94.9%, respectively, for moxifloxacin (0.5 µg/mL). The accuracy of the GenoType MTBDRsl assay for kanamycin, capreomycin, ofloxacin, and moxifloxacin was lower than that of the BACTEC MGIT 960 SL DST. The BACTEC MGIT 960 SL DST kit and the GenoType MTBDRsl were successful in detecting second-line antituberculosis drug resistance. Preliminary results of the GenoType MTBDRsl are very valuable for early treatment decisions, but we still recommend additional BACTEC MGIT 960 SL DST kit usage in the routine evaluation of drug-resistant tuberculosis.

  1. Evaluation of the BACTEC MGIT 960 SL DST Kit and the GenoType MTBDRsl Test for Detecting Extensively Drug-resistant Tuberculosis Cases

    Science.gov (United States)

    Tekin, Kemal; Albay, Ali; Simsek, Hulya; Sig, Ali Korhan; Guney, Mustafa

    2017-01-01

    Objective: The present study aimed to evaluate the performances of the BACTEC MGIT 960 SL DST kit and the GenoType MTBDRsl test for detecting second-line antituberculosis drug resistance in Multidrug-resistant TB (MDR-TB) cases. Materials and Methods: Forty-six MDR-TB strains were studied. Second-line antituberculosis drug resistances were detected using the BACTEC MGIT 960 SL DST kit and the GenoType MTBDRsl test. The Middlebrook 7H10 agar proportion method was used as the reference test. Results: The sensitivity and specificity values for the BACTEC MGIT 960 SL DST kit were both 100% for amikacin, kanamycin, capreomycin (4 µg/mL), and ofloxacin; 100% and 95.3%, respectively, for capreomycin (10 µg/mL); and 85.7% and 100%, respectively, for moxifloxacin (0.5 µg/mL). The sensitivity and specificity values for the GenoType MTBDRsl test to detect fluoroquinolone and aminoglycoside/cyclic peptide resistance were 88.9% and 100%, respectively, for ofloxacin and 85.7% and 94.9%, respectively, for moxifloxacin (0.5 µg/mL). The accuracy of the GenoType MTBDRsl assay for kanamycin, capreomycin, ofloxacin, and moxifloxacin was lower than that of the BACTEC MGIT 960 SL DST. Conclusion: The BACTEC MGIT 960 SL DST kit and the GenoType MTBDRsl were successful in detecting second-line antituberculosis drug resistance. Preliminary results of the GenoType MTBDRsl are very valuable for early treatment decisions, but we still recommend additional BACTEC MGIT 960 SL DST kit usage in the routine evaluation of drug-resistant tuberculosis. PMID:29123441

  2. Cervical Cancer Screening with HPV Test

    Centers for Disease Control (CDC) Podcasts

    2009-10-15

    Dr. Stewart Massad, a professor in the Division of Gynecologic Oncology at Washington University in Saint Louis and a board member of the American Society for Colposcopy and Cervical Cancer Prevention (ASCCP), talks about cotesting with human papillomavirus (HPV) as part of a cervical cancer screening program.  Created: 10/15/2009 by National Center for Chronic Disease Prevention and Health Promotion (NCCDPHP), Division of Cancer Prevention and Control (DCPC).   Date Released: 6/9/2010.

  3. Clinical Evaluation of Rapid Diagnostic Test Kit for Scrub Typhus with Improved Performance.

    Science.gov (United States)

    Kim, Young-Jin; Park, Sungman; Premaratna, Ranjan; Selvaraj, Stephen; Park, Sang-Jin; Kim, Sora; Kim, Donghwan; Kim, Min Soo; Shin, Dong Hoon; Choi, Kyung-Chan; Kwon, Soon-Hwan; Seo, Wonjun; Lee, Nam Taek; Kim, Seung-Han; Kang, Heui Keun; Kim, Yoon-Won

    2016-08-01

    Diagnosis of scrub typhus is challenging due to its more than twenty serotypes and the similar clinical symptoms with other acute febrile illnesses including leptospirosis, murine typhus and hemorrhagic fever with renal syndrome. Accuracy and rapidity of a diagnostic test to Orientia tsutsugamushi is an important step to diagnose this disease. To discriminate scrub typhus from other diseases, the improved ImmuneMed Scrub Typhus Rapid Diagnostic Test (RDT) was evaluated in Korea and Sri Lanka. The sensitivity at the base of each IgM and IgG indirect immunofluorescent assay (IFA) in Korean patients was 98.6% and 97.1%, and the specificity was 98.2% and 97.7% respectively. The sensitivity and specificity for retrospective diagnosis at the base of IFA in Sri Lanka was 92.1% and 96.1%. ImmuneMed RDT was not reactive to any serum from seventeen diseases including hemorrhagic fever with renal syndrome (n = 48), leptospirosis (n = 23), and murine typhus (n = 48). ImmuneMed RDT shows superior sensitivity (98.6% and 97.1%) compared with SD Bioline RDT (84.4% at IgM and 83.3% at IgG) in Korea. The retrospective diagnosis of ImmuneMed RDT exhibits 94.0% identity with enzyme-linked Immunosorbent assay (ELISA) using South India patient serum samples. These results suggest that this RDT can replace other diagnostic tests and is applicable for global diagnosis of scrub typhus. This rapid and accurate diagnosis will be beneficial for diagnosing and managing scrub typhus.

  4. Evaluation of ELISA screening test for detecting aflatoxin in biogenic dust samples

    Energy Technology Data Exchange (ETDEWEB)

    Durant, J.T.

    1996-05-01

    Aflatoxin is a carcinogenic chemical that is sometimes produced when agricultural commodities are infested by the fungi Aspergillus flavus and A. Parasiticus. Aflatoxin has been found to be present in air samples taken around persons handling materials likely to be contaminated. The purpose of this investigation was to demonstrate the feasibility of using an Enzyme Linked Immunosorbent Assay (ELISA) test kit that was developed to screen for aflatoxin in bulk agricultural commodities, to an air sample. Samples were taken from two environments likely to be contaminated with aflatoxin, a dairy farm feed mixing operation and a peanut bagging operation. The dust collected from these environments was considered to be biogenic, in that it originated primarily from biological materials.

  5. Pre-screening Discussions and Prostate-Specific Antigen Testing for Prostate Cancer Screening.

    Science.gov (United States)

    Li, Jun; Zhao, Guixiang; Hall, Ingrid J

    2015-08-01

    For many men, the net benefit of prostate cancer screening with prostate-specific antigen (PSA) tests may be small. Many major medical organizations have issued recommendations for prostate cancer screening, stressing the need for shared decision making before ordering a test. The purpose of this study is to better understand associations between discussions about benefits and harms of PSA testing and uptake of the test among men aged ≥40 years. Associations between pre-screening discussions and PSA testing were examined using self-reported data from the 2012 Behavioral Risk Factor Surveillance System. Unadjusted prevalence of PSA testing was estimated and AORs were calculated using logistic regression in 2014. The multivariate analysis showed that men who had ever discussed advantages of PSA testing only or discussed both advantages and disadvantages were more likely, respectively, to report having had a test within the past year than men who had no discussions (ptesting with their healthcare providers were more likely (AOR=2.75, 95% CI=2.00, 3.79) to report getting tested than men who had no discussions. Discussions of the benefits or harms of PSA testing are positively associated with increased uptake of the test. Given the conflicting recommendations for prostate cancer screening and increasing importance of shared decision making, this study points to the need for understanding how pre-screening discussions are being conducted in clinical practice and the role played by patients' values and preferences in decisions about PSA testing. Published by Elsevier Inc.

  6. Cost-effectiveness analysis and mortality impact estimation of scaling-up pregnancy test kits in Madagascar, Ethiopia and Malawi.

    Science.gov (United States)

    Kolesar, Robert J; Audibert, Martine; Comfort, Alison B

    2017-07-01

    Cost-effective, innovative approaches are needed to accelerate progress towards ending preventable infant, child and maternal mortality. To inform policy decisions, we conducted a cost-effectiveness analysis of adding urine pregnancy test kits to the maternal and reproductive services package offered at the community level in Madagascar, Ethiopia and Malawi. We used a decision tree model to compare the intervention with the status quo for each country. We also completed single factor sensitivity analyses and Monte Carlo simulations with 10 000 iterations to generate the probability distribution of the estimates and uncertainty limits. Among a hypothetical cohort of 100 000 women of reproductive age, we estimate that over a 1-year period, the intervention would save 26, 35 and 48 lives in Madagascar, Ethiopia, and Malawi, respectively. The Incremental Cost Effectiveness Ratio (ICER) for the cost per life saved varies by country: $2311 [95% Uncertainty Interval (UI): $1699; $3454] in Madagascar; $2969 [UI: $2260; $5041] in Ethiopia and $1228 [UI: $918; $1777] in Malawi. This equates to an average cost per Disability Adjusted Life Year (DALY) averted of $36.28, $47.95 and $21.92, respectively. Based on WHO criteria and a comparison with other maternal, newborn, and child health interventions, we conclude that the addition of urine pregnancy tests to an existing community health worker maternal and reproductive services package is highly cost-effective in all three countries. To optimize uptake of family planning and antenatal care services and, in turn, accelerate the reduction of mortality and DALYs, decision makers and program planners should consider adding urine pregnancy tests to the community-level package of services. © The Author 2017. Published by Oxford University Press in association with The London School of Hygiene and Tropical Medicine. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.

  7. False-positive Human Papillomavirus DNA tests in cervical screening

    DEFF Research Database (Denmark)

    Rebolj, Matejka; Pribac, Igor; Lynge, Elsebeth

    2011-01-01

    Based on data from randomised controlled trials (RCT) on primary cervical screening, it has been reported that the problem of more frequent false-positive tests in Human Papillomavirus (HPV) DNA screening compared to cytology could be overcome. However, these reports predominantly operated...

  8. Solubility tests and the peripheral blood film method for screening ...

    African Journals Online (AJOL)

    Objective. To determine the cost benefit of screening for sicklecell disease among infants at district health centres in Uganda using sickling, solubility tests and the peripheral blood film method. Methods. Pilot screening services were established at district health centres. Cost benefit analysis (CBA) was performed in four ...

  9. Screening for suppression in young children: the Polaroid Suppression test

    NARCIS (Netherlands)

    Pott, J.W.R.; Oosterveen, DK; Van Hof-van Duin, J

    1998-01-01

    Background: Assessment of monocular visual impairment during screening of young children is often hampered by lack of cooperation. Because strabismus, amblyopia, or anisometropia may lead to monocular suppression during binocular viewing conditions, a test was developed to screen far suppression in

  10. Testing the Untestable: A Vision Screening Program for Exceptional Children.

    Science.gov (United States)

    Bishop, Virginia E.; Godolphin, Vivienne

    Based on a longitudinal study of vision screening techniques for handicapped children at the Chester County (Pennsylvania) Child Development Center, the paper reports on the development of a battery of effective vision screening methods for children with low functioning handicapped children. Specific tests are described, including the Sheridan…

  11. Physician-patient discussions of controversial cancer screening tests.

    Science.gov (United States)

    Dunn, A S; Shridharani, K V; Lou, W; Bernstein, J; Horowitz, C R

    2001-02-01

    Screening mammography for younger women and prostate-specific antigen (PSA) measurement have controversial benefits and known potential adverse consequences. While providing informed consent and eliciting patient preference have been advocated for these tests, little is known about how often these discussions take place or about barriers to these discussions. We administered a survey to medical house staff and attending physicians practicing primary care. The survey examined physicians' likelihood of discussing screening mammography and PSA testing, and factors influencing the frequency and quality of these discussions. For the three scenarios, 16% to 34% of physicians stated that they do not discuss the screening tests. The likelihood of having a discussion was significantly associated with house staff physicians' belief that PSA screening is advantageous; house staff and attending physicians' intention to order a PSA test, and attending physicians' intention to order a mammogram; and a controversial indication for screening. The most commonly identified barriers to discussions were lack of time, the complexity of the topic, and a language barrier. Physicians report they often do not discuss cancer screening tests with their patients. Our finding that physicians' beliefs and intention to order the tests, and extraneous factors such as time constraints and a language barrier, are associated with discussions indicates that some patients may be inappropriately denied the opportunity to choose whether to screen for breast and prostate cancer.

  12. Physician–Patient Discussions of Controversial Cancer Screening Tests

    Science.gov (United States)

    Dunn, Andrew S.; Shridharani, Kanan V.; Lou, Wendy; Bernstein, Jeffrey; Horowitz, Carol R.

    2016-01-01

    Background Screening mammography for younger women and prostate-specific antigen (PSA) measurement have controversial benefits and known potential adverse consequences. While providing informed consent and eliciting patient preference have been advocated for these tests, little is known about how often these discussions take place or about barriers to these discussions. Methods We administered a survey to medical house staff and attending physicians practicing primary care. The survey examined physicians’ likelihood of discussing screening mammography and PSA testing, and factors influencing the frequency and quality of these discussions. Results For the three scenarios, 16% to 34% of physicians stated that they do not discuss the screening tests. The likelihood of having a discussion was significantly associated with house staff physicians’ belief that PSA screening is advantageous; house staff and attending physicians’ intention to order a PSA test, and attending physicians’ intention to order a mammogram; and a controversial indication for screening. The most commonly identified barriers to discussions were lack of time, the complexity of the topic, and a language barrier. Conclusions Physicians report they often do not discuss cancer screening tests with their patients. Our finding that physicians’ beliefs and intention to order the tests, and extraneous factors such as time constraints and a language barrier, are associated with discussions indicates that some patients may be inappropriately denied the opportunity to choose whether to screen for breast and prostate cancer. PMID:11165455

  13. 42 CFR 410.18 - Diabetes screening tests.

    Science.gov (United States)

    2010-10-01

    ... screening tests. (a) Definitions. For purposes of this section, the following definitions apply: Diabetes... receive the benefit: (1) Hypertension. (2) Dyslipidemia. (3) Obesity, defined as a body mass index greater...

  14. Long-lived immunity to canine core vaccine antigens in UK dogs as assessed by an in-practice test kit.

    Science.gov (United States)

    Killey, R; Mynors, C; Pearce, R; Nell, A; Prentis, A; Day, M J

    2018-01-01

    To determine the utility of an in-practice test kit to detect protective serum antibody against canine distemper virus, canine adenovirus and canine parvovirus type 2 in a sample of the UK dog population. Serum samples from 486 dogs, last vaccinated between less than 1 month and 124 months previously, were tested with the VacciCheck™ test kit for protective antibodies against distemper, adenovirus and parvovirus type 2. A high proportion of the dogs tested (93·6%) had protective antibody against all three of the core vaccine antigens: 95·7% of the dogs were seropositive against canine distemper virus, 97·3% against canine adenovirus and 98·5% against canine parvovirus type 2. The small number of dogs that were seronegative for one or more of the antigens (n = 31) may have had waning of previous serum antibody or may have been rare genetic non-responders to that specific antigen. UK veterinarians can be reassured that triennial revaccination of adult dogs with core vaccines provides long-lived protective immunity. In-practice serological test kits are a valuable tool for informing decision-making about canine core revaccination. © 2017 British Small Animal Veterinary Association.

  15. Nested-PCR and a new ELISA-based NovaLisa test kit for malaria diagnosis in an endemic area of Thailand.

    Science.gov (United States)

    Thongdee, Pimwan; Chaijaroenkul, Wanna; Kuesap, Jiraporn; Na-Bangchang, Kesara

    2014-08-01

    Microscopy is considered as the gold standard for malaria diagnosis although its wide application is limited by the requirement of highly experienced microscopists. PCR and serological tests provide efficient diagnostic performance and have been applied for malaria diagnosis and research. The aim of this study was to investigate the diagnostic performance of nested PCR and a recently developed an ELISA-based new rapid diagnosis test (RDT), NovaLisa test kit, for diagnosis of malaria infection, using microscopic method as the gold standard. The performance of nested-PCR as a malaria diagnostic tool is excellent with respect to its high accuracy, sensitivity, specificity, and ability to discriminate Plasmodium species. The sensitivity and specificity of nested-PCR compared with the microscopic method for detection of Plasmodium falciparum, Plasmodium vivax, and P. falciparum/P. vivax mixed infection were 71.4 vs 100%, 100 vs 98.7%, and 100 vs 95.0%, respectively. The sensitivity and specificity of the ELISA-based NovaLisa test kit compared with the microscopic method for detection of Plasmodium genus were 89.0 vs 91.6%, respectively. NovaLisa test kit provided comparable diagnostic performance. Its relatively low cost, simplicity, and rapidity enables large scale field application.

  16. Indicators for monitoring screening programs with primary HPV test.

    Science.gov (United States)

    Zorzi, Manuel; Giorgi Rossi, Paolo

    2017-01-01

    following scientific evidence produced in numerous studies, as well as national and international guidelines, organized cervical cancer screening programs in Italy have gradually introduced the HPV test as primary screening test, replacing cytology. As public health interventions, screening programs must ensure equity, improvement in quality of life, and adequate information for the population involved with regards to benefits and possible risks; therefore, it is essential for quality to be constantly checked at every phase of the project.The Italian Cervical Screening Group (Gruppo Italiano per lo Screening Cervicale, GISCi) has written a handbook for the calculation and interpretation of cervical screening program monitoring indicators that take into account the new protocol based on primary HPV test with cytology triage. based on the European guidelines and Italian recommendations on primary HPVbased screening, the working group, which includes professionals from all the fields involved in cervical screening, identified the essential points needed to monitor the screening process, the accuracy of individual tests, and early outcomes, defining a specific indicator for each aspect. The indicators were grouped as follows: baseline indicators, indicators for test repeat after one year, cumulative indicators, and waiting times. For every indicator, the source of data, calculation formula, any standards or critical thresholds, and interpretation were defined. The standards are based on the results of NTCC trials or Italian pilot studies. the main indicators proposed for the organization are the following: number of invitations, compliance with first invitation, with one-year test repeat and with colposcopy; for test and process accuracy, a cohort approach was utilised, where indicators are based on women who must be followed for at least one year, so as to integrate the results obtained after the first HPV test with the outcome of the test's repetition after one year

  17. Unconfirmed reactive screening tests and their impact on donor management

    International Nuclear Information System (INIS)

    Rahman, M.; Khan, S.A.

    2008-01-01

    To determine the percentage of false positive testing for transfusion transmitted infections (TTIs) using immunochromatographic test (ICT) as first line of screening tests and its effect on loss of volunteer blood donors. Over a period of three months, samples from blood bags of donors undergoing phlebotomy at teaching hospital blood banks in Lahore were screened for human immunodeficiency virus (HIV), hepatitis B (HBV) and hepatitis C (HCV) by immunochromatographic tests. Those found positive on initial screening were re-tested by ELISA method at the screening laboratory of the Institute of Haematology and Blood Transfusion Service, Punjab. Lahore. Out of a total of 62090 voluntary blood donors, 469 donors were found to be initially reactive for either HIV, HBV or HCV. Amongst these 96 (0.15%) blood donors were found to have tested falsely positive for HIV, HBV or HCV as compared to testing by ELISA. False positive testing rate of 0.15% or 96 out of a total of 62090 donors is rather small in terms of loss of voluntary donors and appropriate utilization of available resources. Although immunochromatographic testing is not the gold standard, however it serves an important purpose of initial donor screening. (author)

  18. Evaluation of two commercial, rapid, ELISA kits testing or scrapie in retro-pharyngeal lymph nodes in sheep

    NARCIS (Netherlands)

    Kittelberger, R.; McIntuyre, L.; Watts, S.; MacDiarmid, S.; Hannah, M.J.; Jenner, J.; Bueno, R.; Swainsbury, R.; Langeveld, J.P.M.; Keulen, van L.J.M.; Zijderveld, van F.G.; Wemheuer, W.M.; Richt, J.A.; Sorenson, S.J.; Pigott, C.J.; O'Keefe, J.S.

    2014-01-01

    AIMS: To estimate the number of cases of scrapie that would occur in sheep of different prion protein (PrP) genotypes if scrapie was to become established in New Zealand, and to compare the performance of two commercially available, rapid ELISA kits using ovine retro-pharyngeal lymph nodes (RLN)

  19. Do doctors understand the test characteristics of lung cancer screening?

    Science.gov (United States)

    Schmidt, Richard; Breyer, Marie; Breyer-Kohansal, Robab; Urban, Matthias; Funk, Georg-Christian

    2018-04-01

    Screening for lung cancer with a low-dose computed tomography (CT) scan is estimated to prevent 3 deaths per 1000 individuals at high risk; however, false positive results and radiation exposure are relevant harms and deserve careful consideration. Screening candidates can only make an autonomous decision if doctors correctly inform them of the pros and cons of the method; therefore, this study aimed to evaluate whether doctors understand the test characteristics of lung cancer screening. In a randomized trial 556 doctors (members of the Austrian Respiratory Society) were invited to answer questions regarding lung cancer screening based on online case vignettes. Half of the participants were randomized to the group 'solutions provided' and received the correct solutions in advance. The group 'solutions withheld' had to rely on prior knowledge or estimates. The primary endpoint was the between-group difference in the estimated number of deaths preventable by screening. Secondary endpoints were the between-group differences in the prevalence of lung cancer, prevalence of a positive screening results, sensitivity, specificity, positive predictive value, and false negative rate. Estimations were also compared with current data from the literature. The response rate was 29% in both groups. The reduction in the number of deaths due to screening was overestimated six-fold (95% confidence interval CI: 4-8) compared with the actual data, and there was no effect of group allocation. Providing the correct solutions to doctors had no systematic effect on their answers. Doctors poorly understand the test characteristics of lung cancer screening. Providing the correct solutions in advance did not improve the answers. Continuing education regarding lung cancer screening and the interpretation of test characteristics may be a simple remedy. Clinical trial registered with www.clinicaltrials.gov (NCT02542332).

  20. Reiter haemagglutination test: a screening test for syphilis.

    OpenAIRE

    Al-Qudah, A A; Mostratos, A

    1982-01-01

    Using an ultrasonicate of the Reiter treponeme as antigen the Reiter haemagglutination test (RHA) was evaluated as a serological test for syphilis. Comparison of the results of the cardiolipin Wassermann reaction, Reiter protein complement-fixation test, the fluorescent treponemal antibody-absorbed (FTA-ABS) test, the Treponema pallidum haemagglutination test (TPHA) (at dilutions of 1/16 and 1/80), and the Venereal Disease Research Laboratory test with those of the RHA showed that the RHA was...

  1. The use of screening tests in spacecraft lubricant evaluation

    Science.gov (United States)

    Kalogeras, Chris; Hilton, Mike; Carre, David; Didziulis, Stephen; Fleischauer, Paul

    1993-01-01

    A lubricant screening test fixture has been devised in order to satisfy the need to obtain lubricant performance data in a timely manner. This fixture has been used to perform short-term tests on potential lubricants for several spacecraft applications. The results of these tests have saved time by producing qualitative performance rankings of lubricant selections prior to life testing. To date, this test fixture has been used to test lubricants for 3 particular applications. The qualitative results from these tests have been verified by life test results and have provided insight into the function of various anti-wear additives.

  2. [Comparison of eight screening tests for ant-HCV antibody].

    Science.gov (United States)

    Deguchi, Matsuo; Kagita, Masanori; Yamashita, Naoko; Nakano, Takasi; Tahara, Kazuko; Asari, Seishi; Iwatani, Yoshinori

    2002-09-01

    We compared eight HCV screening tests for detection of anti-HCV antibody; Ortho Quick Chaser HCV Ab (QC), Ortho HCV Ab ELISA III (ELISA), Ortho HVC Ab PA test III (PA), Lumipulse II Ortho HCV (LUMI), IMx HCV.DAINAPACKII (IMx), ARCHITECT HCV (ARCH), Immucheck.F-HCV C50 Ab (Immu), RANREAM HCV Ab Ex II (RAN). Sera from six hundred patients were examined by these eight screening tests. The positive rates of the eight screening tests were from 9.0% to 13.2%. Forty-five sera showed discrepant results between the eight screening tests, and about half of them showed weak positive reaction and/or false positive. Twenty-five of the forty-five sera were negative for ant-HCV antibody in the CHIRON RIBA III confirmatory test, and forty-four of them were negative for HCV-RNA in the PCR method. The agreement rates between the two reagents were from 95.5% to 99.2%, but were not always high between the two reagents that used similar antigen. The specificities and sensitivities evaluated by using the RIBA III confirmatory test were excellent in ELISA, LUMI, IMx, ARCH and Immu. Three BBI seroconversion panels were used to compare the positive readings in the initial stage of HCV infection by eight screening tests. ELISA and ARCH showed the earliest positive readings, and then IMx, LUMI = RAN, PA, QC and Immu in this order. These findings indicate that ELISA and ARCH were the most excellent in the sensitivity, specificity and early diagnosis of HCV infection. However, we must pay attention to the weak positive reaction in the screening tests, because there is a possibility of "false positive".

  3. Screening mammography interpretation test: more frequent mistakes

    International Nuclear Information System (INIS)

    Gozzi, Gino; Ganzetti, Alessandra; Martinoli, Carlo; Bacigalupo, Lorenzo; Bodini, Maria; Fiorentino, Carla; Marini, Ugo Paolo; Santini, Dolores

    2005-01-01

    Purpose: To present the mammographic cases most commonly misinterpreted by the participants in the mammography self-test proposed by the Italian Society of Medical Radiology (SIRM) National Congress in Rimini, Italy, 2002, by analysing the findings responsible for errors, suggesting reasons for the errors, and assessing possible inadequacies in the format of the test. Materials and methods: The self-test was performed on the mammograms of 160 cases (32 positive and 128 negative for cancer as confirmed by histology). The mammograms had been taken in the four standard projections and placed on four multi-panel diaphanoscopes, each displaying a set of 40 cases comprising benign and malignant cases in equal proportions. The participants were given pre-printed forms on which to note down their diagnostic judgement. We evaluated a total of 134 fully-completed forms. Among these, we identified the 23 cases most frequently misread by over 15 participants in percentages varying between 40-90%. Of these cases, 10 were malignancies and 13 were negative mammograms. On review, we also assessed the diagnostic contribution of complementary investigations (not available the participants). The 134 fully-completed forms (all of the 40 cases) yielded a total of 5360 responses, 1180 of which (22.01%) were incorrect. Of these 823 out of the 4288 cases expected to be negative (19.2%) were false positive, and 357 out of the 1072 cases expected to be positive (33.3%) were false negative. As regards the 23 most frequently misread cases, these were 10/32 (31.25%) mammograms positive for malignancy and 13/128 (10.15%) negative mammograms or mammograms showing benign disease. The 10 malignancies included 7 infiltrating ductal carcinomas, 1 infiltrating cribriform carcinoma, 1 infiltrating tubular carcinoma, and 1 carcinoma in situ. The 13 cases of benign disease - as established by histology or long-term follow-up - mistaken for malignancies by the test participants were fibrocystic breast

  4. Evaluation of screening tests for colorectal cancer.

    Science.gov (United States)

    Bolt, R J

    1980-12-01

    The following guidelines are proposed for the asymptomatic patient representing for routine examination. Instruct the patient to eat All Bran cereal or a similar product for breakfast for three consecutive days prior to the day of appointment. At the time of appointment the stool obtained from rectal examination or from a spontaneous bowel movement is checked for occult blood using the guaiac method. If the findings are negative, no further tests are recommended. If positive, the patient is given complete dietary instructions in a non-meat, high-residue diet with avoidance of beets, horseradish, vitamins, or aspirin-containing compounds. The patient is then given six Hemoccult or Quikcult slides and is instructed to prepare two fecal slides from each stool specimen daily for three days. If these are all negative when tested, no further studies are necessary. If one or more are positive, however, sigmoidoscopic examination and colon and upper gastrointestinal radiography should be carried out in that order. Evidence that early lesions (Duke A or B) are detected and the cure rate improved with this procedure is quite convincing.

  5. The use of screening tests in aviation medicine

    International Nuclear Information System (INIS)

    Ruge, A.

    2000-01-01

    Pilots have to submit themselves in regular intervals to medical examinations in order to avoid a sudden incapacitation that could endanger flight safety. In Germany these examinations include screening tests to detect an illness in an early phase and to guide the pilot to keep up his/her health. European Joint Aviation Requirements have no provisions for screening tests. Under Council Directive 96/29/EURATOM flight crews in Germany will have to undergo special medical radiation protection examinations. The introduction of any screening tests that give information about individual reactions to cosmic radiation exposure are very unlikely if results are not kept confidential, as this would limit the choice of profession. Flight crews should be made aware of these tests. (orig.) [de

  6. Screening for Specific Language Impairment in Preschool Children: Evaluating a Screening Procedure Including the Token Test

    Science.gov (United States)

    Willinger, Ulrike; Schmoeger, Michaela; Deckert, Matthias; Eisenwort, Brigitte; Loader, Benjamin; Hofmair, Annemarie; Auff, Eduard

    2017-01-01

    Specific language impairment (SLI) comprises impairments in receptive and/or expressive language. Aim of this study was to evaluate a screening for SLI. 61 children with SLI (SLI-children, age-range 4-6 years) and 61 matched typically developing controls were tested for receptive language ability (Token Test-TT) and for intelligence (Wechsler…

  7. Diagnostic value of serologic tests in celiac screening

    Directory of Open Access Journals (Sweden)

    Hosein Saneian

    2012-01-01

    Conclusions: According to our study results, there is no correlation between gastrointestinal symptoms such as vomiting diarrhea, anorexia, bulimia, and failure to thrive (FFT with celiac. TTG was the best screening test method to diagnose celiac disease and other tests such as AGA and EMA do not have high diagnostic value.

  8. Comparison of a new digital KM screen test with conventional Hess and Lees screen tests in the mapping of ocular deviations.

    Science.gov (United States)

    Thorisdottir, Rannveig Linda; Sundgren, Johanna; Sheikh, Rafi; Blohmé, Jonas; Hammar, Björn; Kjellström, Sten; Malmsjö, Malin

    2018-05-28

    To evaluate the digital KM screen computerized ocular motility test and to compare it with conventional nondigital techniques using the Hess and Lees screens. Patients with known ocular deviations and a visual acuity of at least 20/100 underwent testing using the digital KM screen and the Hess and Lees screen tests. The examination duration, the subjectively perceived difficulty, and the patient's method of choice were compared for the three tests. The accuracy of test results was compared using Bland-Altman plots between testing methods. A total of 19 patients were included. Examination with the digital KM screen test was less time-consuming than tests with the Hess and Lees screens (P digital KM screen). Patients found the test with the digital KM screen easier to perform than the Lees screen test (P = 0.009) but of similar difficulty to the Hess screen test (P = 0.203). The majority of the patients (83%) preferred the digital KM screen test to both of the other screen methods (P = 0.008). Bland-Altman plots showed that the results obtained with all three tests were similar. The digital KM screen is accurate and time saving and provides similar results to Lees and Hess screen testing. It also has the advantage of a digital data analysis and registration. Copyright © 2018 American Association for Pediatric Ophthalmology and Strabismus. Published by Elsevier Inc. All rights reserved.

  9. Cognitive Screening Tests Versus Comprehensive Neuropsychological Test Batteries: A National Academy of Neuropsychology Education Paper†.

    Science.gov (United States)

    Roebuck-Spencer, Tresa M; Glen, Tannahill; Puente, Antonio E; Denney, Robert L; Ruff, Ronald M; Hostetter, Gayle; Bianchini, Kevin J

    2017-06-01

    The American Medical Association Current Procedural Panel developed a new billing code making behavioral health screening a reimbursable healthcare service. The use of computerized testing as a means for cognitive screening and brief cognitive testing is increasing at a rapid rate. The purpose of this education paper is to provide information to clinicians, healthcare administrators, and policy developers about the purpose, strengths, and limitations of cognitive screening tests versus comprehensive neuropsychological evaluations. Screening tests are generally brief and narrow in scope, they can be administered during a routine clinical visit, and they can be helpful for identifying individuals in need of more comprehensive assessment. Some screening tests can also be helpful for monitoring treatment outcomes. Comprehensive neuropsychological assessments are multidimensional in nature and used for purposes such as identifying primary and secondary diagnoses, determining the nature  and severity of a person's cognitive difficulties, determining functional limitations, and planning treatment and rehabilitation. Cognitive screening tests are expected to play an increasingly important role in identifying individuals with cognitive impairment and in determining which individuals should be referred for further neuropsychological assessment. However, limitations of existing cognitive screening tests are present and cognitive screening tests should not be used as a replacement for comprehensive neuropsychological testing. © The Author 2017. Published by Oxford University Press. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.

  10. Test plan for Tank 241-AW-101 solubility screening tests

    International Nuclear Information System (INIS)

    Person, J.C.

    1998-01-01

    Tank 241-AW-101 (101-AW) has been identified as one of the early tanks to be for retrieved for low level waste pretreatment and immobilization and retrieval of the tank waste may require dilution. This test is to determine the effects of dilution on the mass of solids and their composition. This test plan gives test instructions, example data sheets, a waste compatibility review, and a waste stream fact sheet. This test Plan is similar to tests on tanks 241-AN-102 (Person 1998a) and 241-AN-107 (Person 1998 b). The 101-AW tests will be done with composites of liquid and solids from grab samples that were taken in 1998 (Benar 1998). Future revisions of the Tank Sampling and Analysis Plan (Benar 1998) may change the details of the work performed under this test plan

  11. Human papillomavirus testing and genotyping in cervical screening

    DEFF Research Database (Denmark)

    Rebolj, Matejka; Lynge, Elsebeth; Bonde, Jesper

    2011-01-01

    the incidence of cervical cancer, but has a low sensitivity for high-grade cervical intraepithelial neoplasia (CIN) and requires frequent testing. Several HPV tests have become available commercially. They appear to be more sensitive for high-grade CIN, and may further reduce the incidence of cervical cancer......Mass vaccination against human papillomavirus (HPV) genotypes 16 and 18 will, in the long term, reduce the incidence of cervical cancer, but screening will remain an important cancer control measure in both vaccinated and unvaccinated women. Since the 1960s, cytology screening has helped to reduce...

  12. The development of new diagnostic test-systems and improvement of the existed radio immunochemical kits in the industrial production conditions

    International Nuclear Information System (INIS)

    Abdukayumov, A.M.

    2002-04-01

    The highly effective method had been developed for HBsAg preparing and purification that allowed to use as the raw material a plasma of donors with low content of the target product and based on the application of the stepped fractionation by Ammonium Sulphate and affinity chromatography. The use efficiency of the produced HBsAg preparations had been shown for laboratory animals immunization with the purpose of antiserum production that was the intermediate product for component manufacture needed for high sensitive kit creation; for preparation of affinity immunosorbent with the purpose of highly specific anti-HBs preparing. The method had been developed for production of anti-HBs preparations with standard immunoreactivity from donkey serum by means of specific antibodies fractionation on affinity immunosorbent. The work was done to finish the method for 125 I incorporation into the monoclonal mouse antibody molecules resulting maximum high biological activity. It was determined that the highest quality provided by approach of the isotope introduction by means of Chloraimine T reagent. It had been developed and introduced into industrial production the modified highly sensitive kit 'IRMA-M-HBsAg- 125 I' for HBsAg detection in human blood serum with use of monoclonal antibodies with the help of which it was managed to increase the stability and sensitivity and to standardize the technology of the kit. The technology had been developed and completed the laboratory and clinical testing of the kits of reagents 'IRMA-M-HBsAg- 125 I', 'ELISA-HBsAg', 'Recombinant-anti-HCV-strip' that had shown the high specificity and reproduction of the analysis results. Immunoenzymetic kit 'ELISA-HBsAg' of the third generation for HBsAg detection in human blood serum with the sensitivity not less than 0.5 ng/ml was introduced into industrial production. It had been developed and introduced into industrial production the highly sensitive immunoenzymetic test-system 'Recombinant

  13. Accuracy of a point-of-care ELISA test kit for predicting the presence of protective canine parvovirus and canine distemper virus antibody concentrations in dogs.

    Science.gov (United States)

    Litster, A L; Pressler, B; Volpe, A; Dubovi, E

    2012-08-01

    Canine parvovirus (CPV) and canine distemper virus (CDV) are highly infectious and often fatal diseases with worldwide distributions, and are important population management considerations in animal shelters. A point-of-care ELISA test kit is available to detect serum antibodies to CPV and CDV, and presumptively to predict protective status. The aim of this study was to determine the diagnostic accuracy of the test compared to CPV hemagglutination inhibition titers and CDV serum neutralization titers determined by a reference laboratory, using sera collected from dogs housed at animal shelters. The ELISA test was used under both field and laboratory conditions and duplicate specimens were processed using an extra wash step. The test kit yielded accurate results (CPV: sensitivity 92.3%, specificity 93.5%; CDV: sensitivity 75.7%, specificity 91.8%) under field conditions. CDV sensitivity was improved by performing the test under laboratory conditions and using an optical density (OD) meter (laboratory performed 94.0%; OD 88.1%). Point-of-care ELISA testing for serum CPV and CDV antibody titers was demonstrated to be a useful tool for determining antibody status when making decisions regarding the need for CPV and/or CDV vaccination and also in animal shelters for population management. Copyright © 2012 Elsevier Ltd. All rights reserved.

  14. Comparação de kits ELISA® comerciais para anticorpos no soro e leite com um teste coproparasitológico em bovinos naturalmente infectados por Fasciola hepatica Comparison of comercial® ELISA kits for antibodies in serum and milk with a fecal test in cattle naturally infected with Fasciola hepatica

    Directory of Open Access Journals (Sweden)

    Cíntia das C. Bernardo

    2013-01-01

    Full Text Available A fasciolose é uma enfermidade causada por um trematoda que acomete o fígado principalmente de ruminantes domésticos, podendo parasitar o homem e seu diagnóstico é realizado rotineiramente por exames coproparasitológicos. O objetivo do presente estudo foi comparar kits comerciais de ELISA para anticorpos no soro e leite com um teste coproprarasitológico em bovinos naturalmente infectados por Fasciola hepatica. Foram coletadas amostras de fezes (92 sangue (92 e leite (43 de bovinos provenientes de propriedades de gado leiteiro do município de Jerônimo Monteiro, sul do Estado do Espírito Santo. As amostras de fezes coletadas foram processadas pela técnica de sedimentação fecal para ovos de F. hepatica, utilizada como padrão ouro para as análises. Amostras de sangue e de leite foram processadas segundo a orientação do fabricante dos respectivos Kits ELISA comerciais testados. Utilizou-se o c² de McNemar para comparação estatística e calcularam-se a sensibilidade e especificidade, valores preditivos e kappa. Os resultados obtidos mostraram que as frequências de positividade pelo uso dos kits ELISA comerciais de soro e de leite diferiram significativamente (pThe fascioliasis is a disease caused by a trematode that affects the liver mainly of domestic ruminants and can also parasite man; its diagnosis is routinely done by coprological methods. The aim of this study was to compare commercial ELISA kits for antibodies in serum and milk with a coprological test in cattle naturally infected by Fasciola hepatica. We collected fecal, blood and milk samples from cattle in the municipality of Jerônimo Monteiro, southern Espírito Santo state. The fecal samples were processed by the fecal egg sedimentation for F. hepatica, which is used as a gold standard for analyzis. Blood (92 and milk (43 samples were processed according to the manufacturer instructions of the respective commercial ELISA kits tested. We used the McNemar chi-square for

  15. Alkaline phosphatase as a screening test for osteomalacia.

    Science.gov (United States)

    Chinoy, Muhammad Amin; Javed, Muhammad Imran; Khan, Alamzeb; Sadruddin, Nooruddin

    2011-01-01

    Vitamin D deficiency remains common in children and adults in Pakistan despite adequate sunlight exposure. Diagnosis in adults is usually delayed and is made following pathological fractures that result in significant morbidity. The objective of this study was to see whether Serum Alkaline Phosphatase levels could be used as a screening test for osteomalacia. The Study was conducted at Fatima Hospital, Baqai Medical University, Gadap, Karachi, between July 2002 and June 2005. Serum calcium levels are commonly used to screen patients suspected of osteomalacia, and raised serum alkaline phosphatase (SALP) is considered a diagnostic finding. We used SALP to screen patients who presented with back or non-specific aches and pain of more than six months duration. Three hundred thirty-four (334) patients were screened of which 116 (35%) had raised SALP. Osteomalacia was diagnosed in 92 (79.3%) of these 116 either by plain radiographs, bone biopsy or isotope bone scan. Fifty-four (53.4%) of the 101 cases had a normal level of serum calcium. Osteomalacia is likely to be missed if only serum calcium is used to screen patients. Serum Alkaline Phosphate should be used as the preferred method for screening these patients.

  16. Screening for Drug Abuse Among College Students: Modification of the Michigan Alcoholism Screening Test

    Science.gov (United States)

    Cannell, M. Barry; Favazza, Armando R.

    1978-01-01

    Modified version of the Michigan Alcoholism Screening Test was anonymously given to 245 college students on two Midwestern university campuses. Cutoff score for suspected drug abuse was set at five points. The percent of students scoring five or more points was 25 and 22 from campuses A and B respectively. (Author)

  17. Embryotoxicity of Mirtazapine: a study using Chick Embryotoxicity Screening Test

    Czech Academy of Sciences Publication Activity Database

    Maňáková, E.; Hubičková, L.; Košťálová, J.; Zemanová, Zdeňka

    2010-01-01

    Roč. 31, Suppl.2 (2010), s. 8-10 ISSN 0172-780X Institutional research plan: CEZ:AV0Z50110509 Keywords : embryo toxicity * screening test * mirtazapine Subject RIV: EA - Cell Biology Impact factor: 1.621, year: 2010

  18. Validation of the Hwalek-Sengstock Elder Abuse Screening Test.

    Science.gov (United States)

    Neale, Anne Victoria; And Others

    Elder abuse is recognized as an under-detected and under-reported social problem. Difficulties in detecting elder abuse are compounded by the lack of a standardized, psychometrically valid instrument for case finding. The development of the Hwalek-Sengstock Elder Abuse Screening Test (H-S/EAST) followed a larger effort to identify indicators and…

  19. Assessment of the Diagnostic Potential of Clinotech TB Screen Test ...

    African Journals Online (AJOL)

    The Clinotech TB Screen test, a 3rd generation multi-antigen rapid chromatographic immunoassay for detection of IgG antibodies in serum against recombinant protein antigens 38kDa, 16kDa and 6kDa, was assessed for its diagnostic potential for diagnosis of active pulmonary TB in routine TB control programme in Abia ...

  20. Measurements for testing of fluoroscopic screens, including the photofluorographic units

    International Nuclear Information System (INIS)

    Balfanz, R.

    1986-01-01

    Image quality control measurements for fluoroscopic screens and photofluorographs have shown that both types of equipment have a long operating life, so that constancy and technical performance tests are absolutely necessary. It is recommended to conclude in-service maintenance contracts with the manufacturers. (DG) [de

  1. Tuberculosis Screening and Targeted Testing of College and University Students

    Science.gov (United States)

    Journal of American College Health, 2011

    2011-01-01

    Screening and targeted testing for tuberculosis (TB) is a key strategy for controlling and preventing infection on college and university campuses. Early detection provides an opportunity to promote the health of affected individuals through prompt diagnosis and treatment while preventing potential spread to others. Implementation of a screening…

  2. A population screening test for antibody to measles virus

    International Nuclear Information System (INIS)

    Friedman, M.G.

    1981-01-01

    In areas where sporadic cases of measles continue to occur in spite of vaccination programs, the availability of a simple screening test for determination of seropositivity to measles virus is desirable. A sensitive radioimmunoassay (RIA) screening test (ST) for the detection of IgG antibody to measles virus, based on a solid phase RIA, is described. The assays were performed on polyvinyl microtiter plates for which the RIAST requires only 5 μl of serum per subject. Antigen consisted of a sonicated extract of measles virus-infected Vero cells. Rabbit antihuman IgG specific for the Fc-segment of human IgG, labelled with 125 I, was used to detect human IgG bound to viral antigen. The basic RIA method was characterized by carrying out full titrations of sera of 53 healthy adults, 10 children, and 13 patients with measles-associated illness. These sera were also tested by the hemagglutination inhibition (HI) technique; most of the measles sera were also tested by complement fixation (CF). RIAST results (expressed as binding ratios) obtained for 52 healthy adults are compared with their RIA serum titers. Of the 200 sera of patients of various ages tested by the RIAST, 63 borderline sera were also tested by HI. The RIAST, which does not require serum treatment other than inactivation, proved to be more sensitive as an indicator of seropositivity than HI. Implications of the results and practical applications of the screening test are discussed. (author)

  3. Perceptions of point-of-care infectious disease testing among European medical personnel, point-of-care test kit manufacturers, and the general public

    Directory of Open Access Journals (Sweden)

    Kaman WE

    2013-06-01

    specialists and POC test kit manufacturers. The general public was much more favorable with respect to a perceived improvement in the quality of healthcare that these tests would bring to the hospital and home environment.Keywords: Survey, questionnaire, point-of-care, microbial diagnosis

  4. Validation of a telephone screening test for Alzheimer's disease.

    Science.gov (United States)

    Camozzato, Ana Luiza; Kochhann, Renata; Godinho, Claudia; Costa, Amanda; Chaves, Marcia L

    2011-03-01

    Financial constraints, mobility issues, medical conditions, crime in local areas can make cognitive assessment difficult for elders and telephone interviews can be a good alternative. This study was carried out to evaluate the reliability, validity and clinical utility of a Brazilian telephone version of the Mini Mental State Examination (Braztel-MMSE) in a community sample of healthy elderly participants and AD patients. The MMSE and the Braztel-MMSE were applied to 66 AD patients and 67 healthy elderly participants. The test-retest reliability was strong and significant (r = .92, p = .01), and the correlation between the Braztel-MMSE and the MMSE were significant (p = .01) and strong (r = .92). The general screening ability of the Braztel-MMSE was high (AUC = 0.982; CI95% = 0.964-1.001). This telephone version can therefore be used as a screening measure for dementia in older adults that need neuropsychological screening and cannot present for an evaluation.

  5. Windows 7 resource kit

    CERN Document Server

    Northrup, Tony; Honeycutt, Jerry; Wilson, Ed

    2009-01-01

    In-depth and comprehensive, this RESOURCE KIT delivers the information you need to administer your Windows 7 system. You get authoritative technical guidance from those who know the technology best-Microsoft Most Valuable Professionals (MVPs) and the Windows 7 product team-along with essential scripts and resources. In addition, "Direct from the Source" sidebars offer deep insights and troubleshooting tips from the Windows 7 team. Get expert guidance on how to: Use Microsoft Deployment Toolkit best practices and tools. Plan user-state migration and test application compatibility.

  6. Tandem walking as a quick screening test for vestibular disorders.

    Science.gov (United States)

    Cohen, Helen S; Stitz, Jasmine; Sangi-Haghpeykar, Haleh; Williams, Susan P; Mulavara, Ajitkumar P; Peters, Brian T; Bloomberg, Jacob J

    2017-12-11

    Although many screening tests of balance are available, few of them have been well validated for clinical or research uses. The goal of this study was to test an updated version of an old test, Tandem Walking, to determine how useful it is for screening patients with vestibular disorders. Case-control study. Subjects were 90 adult patients with vestibular disorders and 292 healthy adult controls. They were tested on the number of correct tandem steps they could perform with arms crossed and eyes closed in a series of 10 steps. Correct steps could be nonconsecutive. Subjects were given one practice trial with eyes open and three experimental trials with eyes closed. Receiver operating characteristic (ROC), and sensitivity and specificity were calculated. ROC values, sensitivity, and specificity were, at best, only moderate, no matter how the age range was cut. Even for subjects in the age group with the highest ROC value (i.e., age less than 50 years), ROC = 0.8, sensitivity = 0.77, and specificity = 0.72. These results indicate that 23% of patients will not be identified. Therefore, we recommend that if this test is used for screening patients in the clinic or healthy volunteers, the result should be interpreted with care. 3b Laryngoscope, 2017. © 2017 The American Laryngological, Rhinological and Otological Society, Inc.

  7. First aid kit

    Science.gov (United States)

    ... this page: //medlineplus.gov/ency/article/001958.htm First aid kit To use the sharing features on this ... ahead, you can create a well-stocked home first aid kit. Keep all of your supplies in one ...

  8. Create an Emergency Kit

    Science.gov (United States)

    ... models take up less space in your kit. Cell phone. Always carry a cell phone and let people know where you are going ... pump in your emergency kit. Remember that despite safety standards and careful monitoring, these devices can fail. ...

  9. Simple test guidelines for screening oilspill sorbents for toxicity

    International Nuclear Information System (INIS)

    Blenkinsopp, S.A.; Sergy, G.; Doe, K.; Jackman, P.; Huybers, A.

    1998-01-01

    Environment Canada's Emergencies Science Division has established a program to develop a standard test method suitable for evaluating the toxicity of common sorbent materials. Sorbents are used to absorb or adsorb spilled oil and other hazardous materials. They vary widely in composition and packaging. They are often treated with oleophilic and hydrophobic compounds to improve performance and have been used in large quantities during oil spills. Until now, their potential toxicity has never been considered. Three tests have been evaluated to determine how appropriate they are in screening the toxicity of sorbents. Seven toxicity test recommendations for sorbents were presented. 7 refs., 3 tabs., 2 figs

  10. A novel test tube method of screening for hemoglobin E.

    Science.gov (United States)

    Tatu, T; Kasinrerk, W

    2012-02-01

    Hemoglobin (Hb) E is a β-structural variant common worldwide. This Hb disorder can form a compound heterozygous state with the β-thalassemia gene, leading to life-threatening hereditary hemolytic anemia, HbE/β-thalassemia. Screening of HbE has proven to be a challenging practice in prevention and control of the HbE/β-thalassemia. A novel test tube method for HbE screening using diethyl aminoethyl (DEAE)-cellulose resin was described. With the developed system, HbE/A(2) did not bind to the resin and remained dissolved in the supernatant, whereas other Hbs completely bound to the resin. The red color of the supernatant observed in the test tube indicated the presence of HbE. Colorless or markedly pale color of the supernatant indicates the absence of HbE. Accuracy and efficiency of the established method in detecting HbE was comparable with the standard cellulose acetate electrophoresis method. The developed method is cheap and simple with no requirement of sophisticated equipment. The reagent could be stored at 4 °C for up to 5 months. Hemolysate samples aged up to 5 months were still suitable for this test. The described novel test tube method could be an alternative method of mass population screening for HbE, particularly in small health care facilities. © 2011 Blackwell Publishing Ltd.

  11. Older adults’ preferences for colorectal cancer-screening test attributes and test choice

    Directory of Open Access Journals (Sweden)

    Kistler CE

    2015-07-01

    Full Text Available Christine E Kistler,1–3 Thomas M Hess,4 Kirsten Howard,5,6 Michael P Pignone,2,3,7 Trisha M Crutchfield,2,3,8 Sarah T Hawley,9 Alison T Brenner,2 Kimberly T Ward,2 Carmen L Lewis10 1Department of Family Medicine, School of Medicine, 2Cecil G Sheps Center for Health Services Research, 3Lineberger Comprehensive Cancer Center, University of North Carolina at Chapel Hill, Chapel Hill, 4Department of Psychology, North Carolina State University, Raleigh, NC, USA; 5Institute for Choice, University of South Australia, Sydney, NSW, Australia; 6School of Public Health, University of Sydney, Sydney, NSW, Australia; 7Division of General Internal Medicine, School of Medicine, 8Center for Health Promotion and Disease Prevention, University of North Carolina at Chapel Hill, Chapel Hill, NC, 9Department of Medicine, University of Michigan, Ann Arbor, MI, 10Division of General Internal Medicine, Department of Medicine, University of Colorado School of Medicine, Aurora, CO, USA Background: Understanding which attributes of colorectal cancer (CRC screening tests drive older adults’ test preferences and choices may help improve decision making surrounding CRC screening in older adults.Materials and methods: To explore older adults’ preferences for CRC-screening test attributes and screening tests, we conducted a survey with a discrete choice experiment (DCE, a directly selected preferred attribute question, and an unlabeled screening test-choice question in 116 cognitively intact adults aged 70–90 years, without a history of CRC or inflammatory bowel disease. Each participant answered ten discrete choice questions presenting two hypothetical tests comprised of four attributes: testing procedure, mortality reduction, test frequency, and complications. DCE responses were used to estimate each participant’s most important attribute and to simulate their preferred test among three existing CRC-screening tests. For each individual, we compared the DCE

  12. Serological Testing in Screening for Adult Celiac Disease

    Directory of Open Access Journals (Sweden)

    Helen Rachel Gillett

    1999-01-01

    Full Text Available Assays for celiac-related antibodies are becoming widely available, and the present review aims to clarify the use of these investigations in the diagnosis of, management of and screening for adult celiac disease. The sensitivities and specificities of various antibody tests are discussed, along with their clinical use as an adjunct to small bowel biopsy, and as a first-line investigation for patients with atypical symptoms of celiac disease or patients at high risk of developing sprue.

  13. Reliability, Validity and Factor Structure of Drug Abuse Screening Test

    OpenAIRE

    Sayed Hadi Sayed Alitabar; Mojtaba Habibi; Maryam Falahatpisheh; Musa Arvin

    2016-01-01

    Background and Objective: According to the increasing of substance use in the country, more researches about this phenomenon are necessary. This Study Investigates the Validity, Reliability and Confirmatory Factor Structure of the Drug Abuse Screening test (DAST). Materials and Methods: The Sample Consisted of 381 Patients (143 Women and 238 Men) with a Multi-Stage Cluster Sampling of Areas 2, 6 and 12 of Tehran Were Selected from Each Region, 6 Randomly Selected Drug Rehabilitation Center. T...

  14. A case of psychosis after use of a detoxification kit and a review of techniques, risks, and regulations associated with the subversion of urine drug tests.

    Science.gov (United States)

    Mittal, Moneeshindra Singh; Kalia, Rachna; Khan, Ahsan Y

    2011-01-01

    The practice of drug testing in the workplace has been adopted for US federal government employees, and many state and local governments as well as private businesses have followed suit. However, a parallel industry dedicated to subverting the results of urine drug testing has emerged with little or no regulation. First, the case of a 19-year-old man who developed psychosis after the use of a detoxification kit is presented. Second, a review of the existing literature on the techniques, risks, and regulations associated with the use of drug tampering kits is provided. PubMed, Cochrane Database, and Google Scholar were searched using the keywords UDS, urine toxicology, pass the drug test, and clean UA, with no restrictions on publication date. Case reports, letters to the editor, and original research and review articles in multiple languages were reviewed, as were federal regulations and acts on the topic. The search yielded 4,082 results, of which 49 articles were selected for relevance. Some articles were later omitted as they had cited the original article and had nothing new to offer. Three commonly used tampering techniques are in vivo adulteration, urine substitution, and in vitro adulteration. Review of the literature regarding the risks involved with use of tampering kits yielded no results. In 1986, an executive order was issued requiring all federal employees to refrain from illicit drug use, and the 1988 Drug-Free Workplace Act precipitated the Substance Abuse and Mental Health Services Administration guidelines and their subsequent revisions. Recently, many states have made regulatory efforts to bring drug test defrauding under the ambit of law. Clinicians need to be aware of the tampering techniques and the possibility of false-negative urine drug tests. Cognizance of inherent risks involved with using these techniques including psychiatric and/or medical complications is also warranted. The manufacture, sale, and use of these products have little or

  15. Protocol for population testing of an Internet-based Personalised Decision Support system for colorectal cancer screening

    Directory of Open Access Journals (Sweden)

    Wilson Carlene J

    2010-09-01

    Full Text Available Abstract Background Australia has a comparatively high incidence of colorectal (bowel cancer; however, population screening uptake using faecal occult blood test (FOBT remains low. This study will determine the impact on screening participation of a novel, Internet-based Personalised Decision Support (PDS package. The PDS is designed to measure attitudes and cognitive concerns and provide people with individually tailored information, in real time, that will assist them with making a decision to screen. The hypothesis is that exposure to (tailored PDS will result in greater participation in screening than participation following exposure to non-tailored PDS or resulting from the current non-tailored, paper-based approach. Methods/design A randomised parallel trial comprising three arms will be conducted. Men and women aged 50-74 years (N = 3240 will be recruited. They must have access to the Internet; have not had an FOBT within the previous 12 months, or sigmoidoscopy or colonoscopy within the previous 5 years; have had no clinical diagnosis of bowel cancer. Groups 1 and 2 (PDS arms will access a website and complete a baseline survey measuring decision-to-screen stage, attitudes and cognitive concerns and will receive immediate feedback; Group 1 will receive information 'tailored' to their responses in the baseline survey and group 2 will received 'non-tailored' bowel cancer information. Respondents in both groups will subsequently receive an FOBT kit. Group 3 (usual practice arm will complete a paper-based version of the baseline survey and respondents will subsequently receive 'non-tailored' paper-based bowel cancer information with accompanying FOBT kit. Following despatch of FOBTs, all respondents will be requested to complete an endpoint survey. Main outcome measures are (1 completion of FOBT and (2 change in decision-to-screen stage. Secondary outcomes include satisfaction with decision and change in attitudinal scores from baseline to

  16. Iterative Cellular Screening System for Nanoparticle Safety Testing

    Directory of Open Access Journals (Sweden)

    Franziska Sambale

    2015-01-01

    Full Text Available Nanoparticles have the potential to exhibit risks to human beings and to the environment; due to the wide applications of nanoproducts, extensive risk management must not be neglected. Therefore, we have constructed a cell-based, iterative screening system to examine a variety of nanoproducts concerning their toxicity during development. The sensitivity and application of various cell-based methods were discussed and proven by applying the screening to two different nanoparticles: zinc oxide and titanium dioxide nanoparticles. They were used as benchmarks to set up our methods and to examine their effects on mammalian cell lines. Different biological processes such as cell viability, gene expression of interleukin-8 and heat shock protein 70, as well as morphology changes were investigated. Within our screening system, both nanoparticle suspensions and coatings can be tested. Electric cell impedance measurements revealed to be a good method for online monitoring of cellular behavior. The implementation of three-dimensional cell culture is essential to better mimic in vivo conditions. In conclusion, our screening system is highly efficient, cost minimizing, and reduces the need for animal studies.

  17. Validation of the Cross-Cultural Alcoholism Screening Test (CCAST).

    Science.gov (United States)

    Gorenc, K D; Peredo, S; Pacurucu, S; Llanos, R; Vincente, B; López, R; Abreu, L F; Paez, E

    1999-01-01

    When screening instruments that are used in the assessment and diagnosis of alcoholism of individuals from different ethnicities, some cultural variables based on norms and societal acceptance of drinking behavior can play an important role in determining the outcome. The accepted diagnostic criteria of current market testing are based on Western standards. In this study, the Munich Alcoholism Test (31 items) was the base instrument applied to subjects from several Hispanic-American countries (Bolivia, Chile, Ecuador, Mexico, and Peru). After the sample was submitted to several statistical procedures, these 31 items were reduced to a culture-free, 31-item test named the Cross-Cultural Alcohol Screening Test (CCAST). The results of this Hispanic-American sample (n = 2,107) empirically demonstrated that CCAST measures alcoholism with an adequate degree of accuracy when compared to other available cross-cultural tests. CCAST is useful in the diagnosis of alcoholism in Spanish-speaking immigrants living in countries where English is spoken. CCAST can be used in general hospitals, psychiatric wards, emergency services and police stations. The test can be useful for other professionals, such as psychological consultants, researchers, and those conducting expertise appraisal.

  18. Screening for Specific Language Impairment in Preschool Children: Evaluating a Screening Procedure Including the Token Test.

    Science.gov (United States)

    Willinger, Ulrike; Schmoeger, Michaela; Deckert, Matthias; Eisenwort, Brigitte; Loader, Benjamin; Hofmair, Annemarie; Auff, Eduard

    2017-10-01

    Specific language impairment (SLI) comprises impairments in receptive and/or expressive language. Aim of this study was to evaluate a screening for SLI. 61 children with SLI (SLI-children, age-range 4-6 years) and 61 matched typically developing controls were tested for receptive language ability (Token Test-TT) and for intelligence (Wechsler Preschool-and-Primary-Scale-of-Intelligence-WPPSI). Group differences were analyzed using t tests, as well as direct and stepwise discriminant analyses. The predictive value of the WPPSI with respect to TT performance was analyzed using regression analyses. SLI-children performed significantly worse on both TT and WPPSI ([Formula: see text]). The TT alone yielded an overall classification rate of 79%, the TT and the WPPSI together yielded an overall classification rate of 80%. TT performance was significantly predicted by verbal intelligence in SLI-children and nonverbal intelligence in controls whilst WPPSI subtest arithmetic was predictive in both groups. Without further research, the Token Test cannot be seen as a valid and sufficient tool for the screening of SLI in preschool children but rather as a tool for the assessment of more general intellectual capacities. SLI-children at this age already show impairments typically associated with SLI which indicates the necessity of early developmental support or training. Token Test performance is possibly an indicator for a more general developmental factor rather than an exclusive indicator for language difficulties.

  19. [Effect evaluation of three ELISA kits in detection of fasciolasis].

    Science.gov (United States)

    Ai, Lin; Chen, Mu-Xin; Chen, Shao-Hong; Chu, Yan-Hong; Cai, Yu-Chun; Zhou, Xiao-Nong; Chen, Jia-Xu

    2013-04-01

    To evaluate the effect of 3 ELISA kits on detection of human fasciolasis. Twenty-six serum samples from patients with fasciolasis, 180 serum samples from patients with other parasitic diseases as well as 26 serum samples from healthy people were detected by ELISA kits which using soluble antigen of Fasciola gigantica, Fasciola hepatica (Fg-ELISA and Fh-ELISA) as well as IgG antigen ELISA detection kits made by DRG company in Germany. The effects of the 3 kits were evaluated. The sensitivities of Fg-ELISA, Fh-ELISA, and DRG-ELISA were 100.0%, 80.8% (95% CI: 65.7%-95.9%) and 100.0%, respectively; the specificities of the three were 87.9% (95% CI: 83.5%-92.4%), 85.0%(95% CI: 80.1%-89.9%) and 83.5% (95% CI: 78.4%-88.6%), respectively, and Youden indexes of them were 0.88, 0.66 and 0.84, respectively. The detection rate of Fg-ELISA (100%) was significantly higher than that of Fh-ELISA (80.8%) (P DRG-ELISA for clinical sample tests as well as massive screening in fasciolasis endemic areas in southwest China.

  20. The validity of the Michigan Alcoholism Screening Test (MAST)

    DEFF Research Database (Denmark)

    Storgaard, H; Nielsen, S D; Gluud, C

    1994-01-01

    This review examines the validity of the Michigan Alcoholism Screening Test (MAST) as a screening instrument for alcohol problems. Studies that compare the MAST-questionnaire with other defined diagnostic criteria of alcohol problems were retrieved through MEDLINE and a cross-bibliographic check....... A total of 20 validity studies were included. The studies varied considerably regarding the prevalence of alcohol problems, the diagnostic criteria, and the examined patient categories. The MAST compared with other diagnostic criteria of alcohol problems gave validity measures with the following span...... and the specificities show substantial variations. The variables that seem to have the largest influence on the PVpos seem to be the prevalence of alcohol problems, the diagnostic method against which the MAST-questionnaire is validated, and the populations on which the MAST is applied. The MAST should in the future...

  1. Validation of Geno-Sen's scrub typhus real time polymerase chain reaction kit by its comparison with a serological ELISA Test

    Directory of Open Access Journals (Sweden)

    Velmurugan Anitharaj

    2017-01-01

    Full Text Available Background: In the recent past, scrub typhus (ST has been reported from different parts of India, based on Weil-Felix/enzyme-linked immunosorbent assay (ELISA/indirect immunofluorescence assay (IFA. Molecular tests are applied only by a few researchers. Aims: Evaluation of a new commercial real time polymerase chain reaction (PCR kit for molecular diagnosis of ST by comparing it with the commonly used IgM ELISA is our aim. Settings and Design: ST has been reported all over India including Puducherry and surrounding Tamil Nadu and identified as endemic for ST. This study was designed to correlate antibody detection by IgM ELISA and Orientia tsutsugamushi DNA in real time PCR. Materials and Methods: ST IgM ELISA (InBios Inc., USA was carried out for 170 consecutive patients who presented with the symptoms of acute ST during 11 months (November, 2015– September, 2016. All 77 of these patients with IgM ELISA positivity and 49 of 93 IgM ELISA negative patients were subjected to real time PCR (Geno-Sen's ST real time PCR, Himachal Pradesh, India. Statistical Analysis: Statistical analysis for clinical and laboratory results was performed using IBM SPSS Statistics 17 for Windows (SPSS Inc., Chicago, USA. Chi-square test with Yates correction (Fisher's test was employed for a small number of samples. Results and Conclusion: Among 77 suspected cases of acute ST with IgM ELISA positivity and 49 IgM negative patients, 42 and 7 were positive, respectively, for O. tsutsugamushi 56-kDa type-specific gene in real time PCR kit. Until ST IFA, the gold standard diagnostic test, is properly validated in India, diagnosis of acute ST will depend on both ELISA and quantitative PCR.

  2. TEST KIT FOR THE DETECTION AND GENOTYPING OF HIGHLY PATHOGENIC INFLUENZA VIRUS A H5N1 BY REAL-TIME POLYMERASE CHAIN REACTION

    Directory of Open Access Journals (Sweden)

    S. V. Stepaniuk

    2014-06-01

    Full Text Available Results of the annual monitoring of epizooties indicate that highly pathogenic HPAI/H5N1 avian influenza widely circulated in Eurasian region. Over a period of 2010–2013 years more than 165 cases of outbreaks in 14 countries were found out. Ukraine became one of the first countries in Europe where in Autonomous Republic of Crimea in October 2005 outbreak of avian epizootic with HPAI/H5N1 was documented and until February 2008 more than 236,000 poultry were killed. Since then the question of monitoring of infected both migrating birds and poultry in places of cross contact in Ukraine remains of high priority. The test system is developed for identification and genotyping A H5N1 on three genes (M, H5 and N1 HPAI/H5N1 in real-time mode for polymerase chain reaction. Test kit capacity to detect HPAI/h5n1avian influenza virus and differentiate it from the other viral infection agents of birds and animals were studied by testing of HPAI/H5N1 virus isolated during mass infection outbreak in Crimea in 2005 and cultural specimens of other viral pathogens. It was established that the «DIA Real Avian Influenza» test kit was capable to detect RNA influenza A virus of high pathogenic H5N1 strains having high sensitivity (100% while RNA of the Crimean HPAI/H5N1 isolate studying and specificity (100% while RNA viruses of Newcastle birds disease, fowl powershift, syndrome of drop in egg production and horse influenza studying.

  3. Evaluation and clinical application of a new commercial test kit (Seralute-Total T3 RIA) for triiodothyronine radioimmunoassay

    International Nuclear Information System (INIS)

    Doi, Kei; Yamamoto, Toshihide

    1975-01-01

    A new radioimmunoassay kit (Seralute) for serum triiodothyronine (T 3 ) was evaluated, and serum T 3 was measured in sera from a variety of thyroid disorders and other conditions associated with altered serum thyroid hormone binding proteins. One or two hundred μl of sera to be measured were mixed with an alkaline solution of 125 I-T 3 on the top of small Sephadex column, by which T 3 was freed from serum binding proteins and adsorbed onto Sephadex. Anti-T 3 anti-body was added to the Sephadex column, and incubation was carried out at room temperature for two hours. The % of free hormone remained on the column after washing the column with buffer. Serum T 3 was assessed from a standard curve. The least detectable T 3 concentration was 10 ng/dl. The intra- and inter-assay variability was approximately 3.0%. The measured T 3 of sera from various thyroid disorders and conditions associated with altered thyroid hormone binding proteins were as follows: euthyroid, 159 +- 29 ng/dl (n=40), hypothyroid, 65 +- 31 ng/dl (n=20), hyperthyroid 450 +- 174 ng/dl (n=20), normal pregnancy 224 +- 38 ng/dl (n=10), idiopathic increase of thyroxine binding globlin (TBG) 224 - 328 ng/dl, idiopathic decrease of TBG 50 - 98 ng/dl, and nephrotic syndrome and cirrhosis of the liver, 58 - 115 ng/dl. (auth.)

  4. Expanded newborn screening by mass spectrometry: New tests, future perspectives.

    Science.gov (United States)

    Ombrone, Daniela; Giocaliere, Elisa; Forni, Giulia; Malvagia, Sabrina; la Marca, Giancarlo

    2016-01-01

    Tandem mass spectrometry (MS/MS) has become a leading technology used in clinical chemistry and has shown to be particularly sensitive and specific when used in newborn screening (NBS) tests. The success of tandem mass spectrometry is due to important advances in hardware, software and clinical applications during the last 25 years. MS/MS permits a very rapid measurement of many metabolites in different biological specimens by using filter paper spots or directly on biological fluids. Its use in NBS give us the chance to identify possible treatable metabolic disorders even when asymptomatic and the benefits gained by this type of screening is now recognized worldwide. Today the use of MS/MS for second-tier tests and confirmatory testing is promising especially in the early detection of new disorders such as some lysosomal storage disorders, ADA and PNP SCIDs, X-adrenoleucodistrophy (X-ALD), Wilson disease, guanidinoacetate methyltransferase deficiency (GAMT), and Duchenne muscular dystrophy. The new challenge for the future will be reducing the false positive rate by using second-tier tests, avoiding false negative results by using new specific biomarkers and introducing new treatable disorders in NBS programs. © 2015 Wiley Periodicals, Inc.

  5. Performance of the Angio Detect™ in-clinic test kit for detection of Angiostrongylus vasorum infection in dog samples from Europe

    DEFF Research Database (Denmark)

    Liu, Jiayou; Schnyder, Manuela; Willesen, Jakob L.

    2017-01-01

    of the Angio Detect test kit by comparing Angio Detect testing results using serum or plasma samples with the results of Baermann-Wetzel testing using matched fecal samples. Samples from 214 dogs [with clinically suspected (N = 195) or diagnosed angiostrongylosis (N = 19)] were used for this evaluation......; sensitivity of the Angio Detect test was 97.1% (95%CI: 85.1%–99.9%). The Angio Detect test was negative for 177 of 179 samples that were negative by the Baermann-Wetzel test; specificity was 98.9% (95%CI: 96.0%–99.9%). In cross-reactivity testing, all 89 samples from dogs confirmed to be infected with other...... common nematodes (Dirofilaria immitis, D. repens, Crenosoma vulpis, hookworms, ascarids, or whipworms) were all negative for A. vasorum by the Angio Detect antigen test. Angio Detect provides a rapid and reliable method for diagnosis of A. vasorum in clinically suspected dogs at risk for infection...

  6. Co-Testing of Cervical Screening Tests in Detection of High Grade Cervical Intraepithelial Neoplasia

    Directory of Open Access Journals (Sweden)

    Smita Asthana

    2017-10-01

    Full Text Available Introduction: Co-testing performance for detection of high grade Cervical Intraepithelial Neoplasia (CIN has not been adequately addressed from Low Resource Countries (LRCs. Where isolated tests do not have adequate performance, further explorations are recommended. Aim: To evaluate the co-testing of conventional cervical screening tests such as Papanicolaou (Pap and Visual Inspection Cervix with Acetic Acid (VIA, with care HPV on Cervical Samples (CHPV or on Vaginal Samples (VHPV in the detection of high grade CIN. Materials and Methods: The cross-sectional study was conducted on ever married women of age 30 to 59 years in a rural community of Dadri. Women were screened by CHPV, VHPV, and Pap and VIA methods. Confirmation of screen positives was done by histology. Sensitivity, Specificity and likelihood ratios of different combinations of test determined to evaluate the performance. Results: Total eligible women, 66.2% (5032/7604 responded for screening. Analysis was performed on 4658, after excluding those who did not complete all screenings. Co-testing of CHPV (OR=246 or VHPV (OR=278 with Pap had highest association. Positive likelihood ratios of CHPV and VHPV with Pap in CIN II+ detection rates were 13.0 and 11.8 and in CIN III+ the detection rates were 18.0 and 16.0 respectively. Higher sensitivities and specificities were observed in co-testing for CIN III+ detection as against CIN II+ lesions. Conclusion: Choice of co-testing in a pair of tests for detection of high grade CIN is likely to depend on whether screening is targeted for developed or low resource country. VIA in isolation might not yield optimal results for LRCs.

  7. Synthesis of enantiomerically enriched drug precursors and an insect pheromone via reduction of ketones using commercially available carbonyl reductase screening kit "Chiralscreen® OH".

    Science.gov (United States)

    Nagai, Toshiya; Sakurai, Saki; Natori, Naoki; Hataoka, Manaka; Kinoshita, Takako; Inoue, Hiroyoshi; Hanaya, Kengo; Shoji, Mitsuru; Sugai, Takeshi

    2018-04-01

    Commercially available "Chiralscreen® OH" starter kit containing five types of carbonyl reductases (E001, E007, E031, E039, and E078) was used for the reduction of several aromatic and aliphatic ketones to obtain enantiomerically enriched drug precursors and an insect pheromone. Almost stereochemically pure secondary alcohols, used in the synthesis of drugs such as (R)-rasagiline mesylate, (S)-rivastigmine, (R)-chlorphenesin carbamate, and (R)-mexiletine, and the insect pheromone (4S,5R)-sitophilure, were conveniently obtained. The enzymes worked well with ketones containing at least one non-bulky substituent at the carbonyl group. The diverse stereochemical preference of the above five carbonyl reductases was clarified. Copyright © 2017 Elsevier Ltd. All rights reserved.

  8. Reaching women who do not participate in the regular cervical cancer screening programme by offering self-sampling kits: a systematic review and meta-analysis of randomised trials.

    Science.gov (United States)

    Verdoodt, F; Jentschke, M; Hillemanns, P; Racey, C S; Snijders, P J F; Arbyn, M

    2015-11-01

    Population coverage for cervical cancer screening is an important determinant explaining differences in the incidence of cervical cancer between countries. Offering devices for self-sampling has the potential to increase participation of hard-to-reach women. A systematic review and meta-analysis were performed to evaluate the participation after an invitation including a self-sampling device (self-sampling arm) versus an invitation to have a sample taken by a health professional (control arm), sent to under-screened women. Sixteen randomised studies were found eligible. In an intention-to-treat analysis, the pooled participation in the self-sampling arm was 23.6% (95% confidence interval (CI)=20.2-27.3%), when self-sampling kits were sent by mail to all women, versus 10.3% (95% CI=6.2-15.2%) in the control arm (participation difference: 12.6% [95% CI=9.3-15.9]). When women had to opt-in to receive the self-sampling device, as used in three studies, the pooled participation was not higher in the self-sampling compared to the control arm (participation difference: 0.2% [95% CI=-4.5-4.9%]). An increased participation was observed in the self-sampling arm compared to the control arm, if self-sampling kits were sent directly to women at their home address. However, the size of the effect varied substantially among studies. Since participation was similar in both arms when women had to opt-in, future studies are warranted to discern opt-in scenarios that are most acceptable to women. Copyright © 2015 Elsevier Ltd. All rights reserved.

  9. Over-the-counter human immunodeficiency virus self-test kits: time to explore their use for men who have sex with men in Brazil

    Directory of Open Access Journals (Sweden)

    Sheri A. Lippman

    2014-05-01

    Full Text Available Increasing access and frequency of human immunodeficiency virus testing are critical to stemming the epidemic. In Brazil's concentrated epidemic, human immunodeficiency virus prevalence in the men who have sex with men/transgender population far exceeds that in the general population, but testing rates fall below what is needed to ensure early detection and treatment. Over-the-counter human immunodeficiency virus self-testing kits, now available in stores in the U.S., have enormous potential to increase testing access and frequency and to facilitate early detection and treatment. With the advent of human immunodeficiency virus self-testing upon us, it is timely to engage the scientific community, government, and civil society in a dialog around how to best utilize this technology in Brazil. We summarize recent research on over-the-counter testing among men who have sex with men, raise potential questions and challenges to using self-tests, suggest implementation strategies, and outline a research agenda moving forward.

  10. Reliability, Validity and Factor Structure of Drug Abuse Screening Test

    Directory of Open Access Journals (Sweden)

    Sayed Hadi Sayed Alitabar

    2016-05-01

    Full Text Available Background and Objective: According to the increasing of substance use in the country, more researches about this phenomenon are necessary. This Study Investigates the Validity, Reliability and Confirmatory Factor Structure of the Drug Abuse Screening test (DAST. Materials and Methods: The Sample Consisted of 381 Patients (143 Women and 238 Men with a Multi-Stage Cluster Sampling of Areas 2, 6 and 12 of Tehran Were Selected from Each Region, 6 Randomly Selected Drug Rehabilitation Center. The DAST Was Used as Instrument. Divergent & Convergent Validity of this Scale Was Assessed with Problems Assessment for Substance Using Psychiatric Patients (PASUPP and Relapse Prediction Scale (RPS.Results: The DAST after the First Time Factor Structure of Using Confirmatory Factor Analysis Was Confirmed. The DAST Had a Good Internal Consistency (Cranach’s Alpha, and the Reliability of the Test Within a Week, 0.9, 0.8. Also this Scale Had a Positive Correlation with Problems Assessment for Substance Using Psychiatric Patients and Relapse Prediction Scale (P<0.01.Conclusion: The Overall Results Showed that the Drug Abuse Screening Test in Iranian Society Is Valid. It Can Be Said that Self-Report Scale Tool Is Useful for Research Purposes and Addiction.

  11. Exploit Kit traffic analysis

    OpenAIRE

    Καπίρης, Σταμάτης; Kapiris, Stamatis

    2017-01-01

    Exploit kits have become one of the most widespread and destructive threat that Internet users face on a daily basis. Since the first actor, which has been categorized as exploit kit, namely MPack, appeared in 2006, we have seen a new era on exploit kit variants compromising popular websites, infecting hosts and delivering destructive malware, following an exponentially evolvement to date. With the growing threat landscape, large enterprises to domestic networks, have starte...

  12. Advances in prenatal screening for Down syndrome: II first trimester testing, integrated testing, and future directions.

    Science.gov (United States)

    Benn, Peter A

    2002-10-01

    The acceptability of prenatal screening and diagnosis of Down syndrome is dependent, in part, on the gestational age at which the testing is offered. First trimester screening could be advantageous if it has sufficient efficacy and can be effectively delivered. Two first trimester maternal serum screening markers, pregnancy-associated plasma protein-A (PAPP-A) and free beta-human chorionic gonadotropin (beta-hCG), are useful for identifying women at increased risk for fetal Down syndrome. In addition, measurement of an enlarged thickness of the subcutaneous fluid-filled space at the back of the neck of the developing fetus (referred to as nuchal translucency or NT) has been demonstrated to be an indicator for these high-risk pregnancies. When these three parameters are combined, estimates for Down syndrome efficacy exceed those currently attainable in the second trimester. Women who are screen-positive in the first trimester can elect to receive cytogenetic testing of a chorionic villus biopsy. The first trimester tests could also, theoretically, be combined with the second trimester maternal serum screening tests (integrated screening) to obtain even higher levels of efficacy. There are, however, several practical limitations to first trimester and integrated screening. These include scheduling of testing within relatively narrow gestational age intervals, availability of appropriately trained ultrasonographers for NT measurement, risks associated with chorionic villus biopsy, and costs. There is also increasing evidence that an enlarged NT measurement is indicative of a high risk for spontaneous abortion and for fetal abnormalities that are not detectable by cytogenetic analysis. Women whose fetuses show enlarged NT, therefore, need first trimester counseling regarding their Down syndrome risks and the possibility of other adverse pregnancy outcomes. Follow-up ultrasound and fetal echocardiography in the second trimester are also indicated. First trimester

  13. Synthetic positive controls for ELISA test kits for detection of IgA and IgM antibodies to Chlamydia trachomatis

    Directory of Open Access Journals (Sweden)

    O. Y. Galkin

    2015-01-01

    Full Text Available The enzyme-linked immunosorbent assay (ELISA is the most informative and versatile method of serological diagnostics. The possibility of detecting by ELISA specific antibodies of different classes allow to differentiate primary infectious process and its remission, exacerbation and chronic disease (holding of differential diagnosis. This approach is implemented in the methodology for evaluation of patients for presence of humoral immune response against the causative agent of urogenital chlamydiosis. As with other infections immediately after Chlamydia trachomatis infection the specific IgM antibodies are formed, and subsequently basic projective antibodies of IgG class are synthesized. However, at exacerbation of chronic urogenital chlamydiosis specific IgA antibodies can be synthesized. That is why comprehensive evaluation of patients for presence of humoral immune response to Ch. trachomatis involves plasma testing of specific antibodies of all three classes. The essential problem in the production of ELISA diagnostic kits is obtaining of positive control. The classic version of positive control is human blood plasma containing specific antibodies. But specific IgM- and IgA-positive sera are deficit raw materials. This fact can significantly limit the production of diagnostic kits, especially in case of large-scale manufacture. We have suggested methodological approach to use of synthetic positive controls in indirect ELISA kits based on conjugate of normal human IgM (IgA and monoclonal antibodies against major outer membrane protein of Ch. trachomatis. It was found that it’s possible to realize such task by means of NHS ester-maleimide-mediated conjugation (by sulfosuccinimidyl-4-(N-maleimidomethylcyclohexane-1-carboxylate and reductive amination-mediated conjugation (by sodium periodate. It was found that synthetic positive controls obtained by different methods are characterized by higher titer compared to IgM- and IgA-positive high

  14. Rapid screening test for porphyria diagnosis using fluorescence spectroscopy

    Science.gov (United States)

    Lang, A.; Stepp, H.; Homann, C.; Hennig, G.; Brittenham, G. M.; Vogeser, M.

    2015-07-01

    Porphyrias are rare genetic metabolic disorders, which result from deficiencies of enzymes in the heme biosynthesis pathway. Depending on the enzyme defect, different types of porphyrins and heme precursors accumulate for the different porphyria diseases in erythrocytes, liver, blood plasma, urine and stool. Patients with acute hepatic porphyrias can suffer from acute neuropathic attacks, which can lead to death when undiagnosed, but show only unspecific clinical symptoms such as abdominal pain. Therefore, in addition to chromatographic methods, a rapid screening test is required to allow for immediate identification and treatment of these patients. In this study, fluorescence spectroscopic measurements were conducted on blood plasma and phantom material, mimicking the composition of blood plasma of porphyria patients. Hydrochloric acid was used to differentiate the occurring porphyrins (uroporphyrin-III and coproporphyrin-III) spectroscopically despite their initially overlapping excitation spectra. Plasma phantom mixtures were measured using dual wavelength excitation and the corresponding concentrations of uroporphyrin-III and coproporphyrin-III were determined. Additionally, three plasma samples of porphyria patients were examined and traces of coproporphyrin-III and uroporphyrin-III were identified. This study may therefore help to establish a rapid screening test method with spectroscopic differentiation of the occurring porphyrins, which consequently allows for the distinction of different porphyrias. This may be a valuable tool for clinical porphyria diagnosis and rapid or immediate treatment.

  15. Development of a Pitch Discrimination Screening Test for Preschool Children.

    Science.gov (United States)

    Abramson, Maria Kulick; Lloyd, Peter J

    2016-04-01

    There is a critical need for tests of auditory discrimination for young children as this skill plays a fundamental role in the development of speaking, prereading, reading, language, and more complex auditory processes. Frequency discrimination is important with regard to basic sensory processing affecting phonological processing, dyslexia, measurements of intelligence, auditory memory, Asperger syndrome, and specific language impairment. This study was performed to determine the clinical feasibility of the Pitch Discrimination Test (PDT) to screen the preschool child's ability to discriminate some of the acoustic demands of speech perception, primarily pitch discrimination, without linguistic content. The PDT used brief speech frequency tones to gather normative data from preschool children aged 3 to 5 yrs. A cross-sectional study was used to gather data regarding the pitch discrimination abilities of a sample of typically developing preschool children, between 3 and 5 yrs of age. The PDT consists of ten trials using two pure tones of 100-msec duration each, and was administered in an AA or AB forced-choice response format. Data from 90 typically developing preschool children between the ages of 3 and 5 yrs were used to provide normative data. Nonparametric Mann-Whitney U-testing was used to examine the effects of age as a continuous variable on pitch discrimination. The Kruskal-Wallis test was used to determine the significance of age on performance on the PDT. Spearman rank was used to determine the correlation of age and performance on the PDT. Pitch discrimination of brief tones improved significantly from age 3 yrs to age 4 yrs, as well as from age 3 yrs to the age 4- and 5-yrs group. Results indicated that between ages 3 and 4 yrs, children's auditory discrimination of pitch improved on the PDT. The data showed that children can be screened for auditory discrimination of pitch beginning with age 4 yrs. The PDT proved to be a time efficient, feasible tool for

  16. Risk of breast cancer after false-positive test results in screening mammography

    DEFF Research Database (Denmark)

    von Euler-Chelpin, My Catarina; Risør, Louise Madeleine; Thorsted, Brian Larsen

    2012-01-01

    Screening for disease in healthy people inevitably leads to some false-positive tests in disease-free individuals. Normally, women with false-positive screening tests for breast cancer are referred back to routine screening. However, the long-term outcome for women with false-positive tests...

  17. Radionuclide transit: a sensitive screening test for esophageal dysfunction

    International Nuclear Information System (INIS)

    Russell, C.O.; Hill, L.D.; Holmes, E.R. III; Hull, D.A.; Gannon, R.; Pope, C.E. II.

    1981-01-01

    The purpose of this study was to extend existing nuclear medicine techniques for the diagnosis of esophageal motor disorders. A standard homogeneous bolus of 99mtechnetium sulfur colloid in water was swallowed in the supine position under the collimator of a gamma camera linked to a microprocessor. Bolus transit was recorded at 0.4-s intervals, and the movie obtained was used to analyze transit in an objective manner. Ten normal volunteers and 30 subjects with dysphagia not related to mechanical obstruction were studied with this technique. Radionuclide transit studies detected a higher incidence of esophageal motor abnormality than manometry or radiology in the dysphagia group. In addition a definitive description of the functional problem was possible in most cases. Radionuclide transit is a safe noninvasive test and suitable as a screening test for esophageal motor disorders

  18. Radionuclide transit: a sensitive screening test for esophageal dysfunction

    Energy Technology Data Exchange (ETDEWEB)

    Russell, C.O.; Hill, L.D.; Holmes, E.R. III; Hull, D.A.; Gannon, R.; Pope, C.E. II

    1981-05-01

    The purpose of this study was to extend existing nuclear medicine techniques for the diagnosis of esophageal motor disorders. A standard homogeneous bolus of 99mtechnetium sulfur colloid in water was swallowed in the supine position under the collimator of a gamma camera linked to a microprocessor. Bolus transit was recorded at 0.4-s intervals, and the movie obtained was used to analyze transit in an objective manner. Ten normal volunteers and 30 subjects with dysphagia not related to mechanical obstruction were studied with this technique. Radionuclide transit studies detected a higher incidence of esophageal motor abnormality than manometry or radiology in the dysphagia group. In addition a definitive description of the functional problem was possible in most cases. Radionuclide transit is a safe noninvasive test and suitable as a screening test for esophageal motor disorders.

  19. PROSTATE CANCER SCREENING: PSA TEST AWARENESS AMONG ADULT MALES.

    Science.gov (United States)

    Obana, Michael; O'Lawrence, Henry

    2015-01-01

    The overall purpose of this study was to determine whether visits to the doctor in the last 12 months, education level, and annual household income for adult males increased the awareness of prostate-specific antigen (PSA) tests. The effect of these factors for the knowledge of PSA exams was performed using statistical analysis. A retrospective secondary database was utilized for this study using the questionnaire in the California Health Interview Survey from 2009. Based on this survey, annual visits to the doctor, higher educational levels attained, and greater take-home pay were statistically significant and the results of the study were equivalent to those hypothesized. This also reflects the consideration of marketing PSA blood test screenings to those adult males who are poor, uneducated, and do not see the doctor on a consistent basis.

  20. Multicentre evaluation of commercial kit methods

    DEFF Research Database (Denmark)

    Gram, J; Declerck, P J; Sidelmann, Johannes Jakobsen

    1993-01-01

    In order to study the analytical performance of different commercial kits for determination of plasminogen activator inhibitor (PAI) activity we distributed eight selected split samples to 11 European laboratories experienced with haemostasis testing. Three different laboratories were involved in...... of the plasma samples, which was PAI-1 depleted. The laboratories involved in the testing reported for this sample a mean value of 6.1 IU/ml.(ABSTRACT TRUNCATED AT 250 WORDS)......In order to study the analytical performance of different commercial kits for determination of plasminogen activator inhibitor (PAI) activity we distributed eight selected split samples to 11 European laboratories experienced with haemostasis testing. Three different laboratories were involved...... in the production of data from each of the commercial kits tested. A considerable variation of PAI activity results reported from the laboratories testing the same commercial kits was observed. The range of reported results could in individual samples exceed the median value indicating an interlaboratory variation...

  1. Pain on Functional Movement Screen Tests and Injury Risk.

    Science.gov (United States)

    Bushman, Timothy T; Grier, Tyson L; Canham-Chervak, Michelle C; Anderson, Morgan K; North, William J; Jones, Bruce H

    2015-11-01

    The Functional Movement Screen (FMS) is a tool intended to evaluate limitations or asymmetries of movement to detect individuals at risk for exercise- and sports-related injury. The purpose was to determine the association and predictive value of specific FMS tests with injury risk in physically active men. Soldiers aged 18-57 years completed the FMS (n = 2,476). Demographic and fitness data were collected by survey. Medical record data for any, overuse, and traumatic injury 6 months after the assessment were obtained. Sensitivity, specificity, positive predictive value (PPV), and negative predictive value were calculated along with receiver operator characteristics to determine area under the curve (AUC). Risks, risk ratios, odds ratios (ORs), and 95% confidence intervals were calculated to assess injury risks. Multivariate logistic regression identified that pain on 5 of the 7 tests was associated with greater risk for any injury (OR = 1.50-3.51): deep squat, hurdle step, in-line lunge, trunk stability push-up, and rotary stability. However, FMS registered low sensitivity, PPV, and AUC for all 7 tests for the 3 injury types (2-24% sensitivity, 16-74% PPV, and 50-58% AUC). Although the presence of pain was associated with a higher risk of injury on 5 tests, a low sensitivity, PPV, and AUC were displayed. Therefore, caution is advised when implementing the FMS as a screening tool in an Army or similarly active population as it could lead to prevention and treatment resources being directed toward individuals who are not at greater risk for injury.

  2. Determining the feline immunodeficiency virus (FIV) status of FIV-vaccinated cats using point-of-care antibody kits.

    Science.gov (United States)

    Westman, Mark E; Malik, Richard; Hall, Evelyn; Sheehy, Paul A; Norris, Jacqueline M

    2015-10-01

    This study challenges the commonly held view that the feline immunodeficiency virus (FIV) infection status of FIV-vaccinated cats cannot be determined using point-of-care antibody test kits due to indistinguishable antibody production in FIV-vaccinated and naturally FIV-infected cats. The performance of three commercially available point-of-care antibody test kits was compared in a mixed population of FIV-vaccinated (n=119) and FIV-unvaccinated (n=239) cats in Australia. FIV infection status was assigned by considering the results of all antibody kits in concert with results from a commercially available PCR assay (FIV RealPCR™). Two lateral flow immunochromatography test kits (Witness FeLV/FIV; Anigen Rapid FIV/FeLV) had excellent overall sensitivity (100%; 100%) and specificity (98%; 100%) and could discern the true FIV infection status of cats, irrespective of FIV vaccination history. The lateral flow ELISA test kit (SNAP FIV/FeLV Combo) could not determine if antibodies detected were due to previous FIV vaccination, natural FIV infection, or both. The sensitivity and specificity of FIV RealPCR™ for detection of viral and proviral nucleic acid was 92% and 99%, respectively. These results will potentially change the way veterinary practitioners screen for FIV in jurisdictions where FIV vaccination is practiced, especially in shelter scenarios where the feasibility of mass screening is impacted by the cost of testing. Copyright © 2015 The Authors. Published by Elsevier Ltd.. All rights reserved.

  3. Knowledge and use of unauthorized HIV self-test kits among men who have sex with men in Spain, following approval of an over-the-counter self-test in the U.S: a cross-sectional study.

    Science.gov (United States)

    Koutentakis, Konstantinos; Rosales-Statkus, María Elena; Hoyos, Juan; Fernández-Balbuena, Sonia; Ruiz, Mónica; Agustí, Cristina; de la Fuente, Luis; Belza, María José

    2016-07-08

    Shortly after the approval of an over-the-counter HIV self-test in the US, we conducted a study to estimate the proportion of men who have sex with men (MSM) in Spain who knew that unauthorized HIV self-tests could be purchased online, and the proportion that had already used these tests, as well as their socio-demographic and behavioural correlates. Between September 2012 and February 2013, MSM users of gay dating websites were invited to complete an online questionnaire. We calculated estimates of the knowledge and use of unauthorized HIV self-testing and assessed the associated factors by rare event logit regression models. Among 8620 participants, 4.2 % (95 % CI:3.8-4.6) knew they could buy an unauthorized HIV self-test kit online, and 12.7 % (95 % CI:12.0-13.4) thought that such a test might exist, although they had never seen one. Only 0.7 % (95 % CI:0.5-0.9) had ever self-tested. In the multivariable analysis, knowledge of online availability of self-tests was associated with being a non-Latin American foreigner, having at least two previous HIV tests, intending to test for HIV in the next year, and knowing about U.S. approval of self-testing. Ever-use of HIV self-testing was associated with being over 34 years of age, living outside Spain during the last 12 months, and knowing about U.S. approval of self-testing. Both knowledge and use of unauthorized HIV self-testing among MSM in Spain was very low among HIV negative or untested MSM in Spain. The recent approval in the United Kingdom and France might increase the number of MSM seeking such testing and possibly using unauthorized test kits not meeting quality standards.

  4. The effect of changing stool collection processes on compliance in nationwide organized screening using a fecal occult blood test (FOBT) in Korea: study protocol for a randomized controlled trial.

    Science.gov (United States)

    Shin, Hye Young; Suh, Mina; Baik, Hyung Won; Choi, Kui Son; Park, Boyoung; Jun, Jae Kwan; Lee, Chan Wha; Oh, Jae Hwan; Lee, You Kyoung; Han, Dong Soo; Lee, Do-Hoon

    2014-11-26

    Colorectal cancer (CRC) screening by fecal occult blood test (FOBT) significantly reduces CRC mortality, and compliance rates directly influence the efficacy of this screening method. The aim of this study is to investigate whether stool collection strategies affect compliance with the FOBT. In total, 3,596 study participants aged between 50 and 74 years will be recruited. The study will be conducted using a randomized controlled trial, with a 2 × 2 factorial design resulting in four groups. The first factor is the method of stool-collection device distribution (mailing vs. visiting the clinic) and the second is the type of stool-collection device (sampling kit vs. conventional container). Participants will be randomly assigned to one of four groups: (1) sampling kit received by mail; (2) conventional container received by mail; (3) sampling kit received at the clinic; (4) conventional container received at the clinic (control group). The primary outcome will be the FOBT compliance rate; satisfaction and intention to be rescreened in the next screening round will also be evaluated. The rates of positive FOBT results and detection of advanced adenomas or cancers through colonoscopies will also be compared between the two collection containers. Identifying a method of FOBT that yields high compliance rates will be a key determinant of the success of CRC screening. The findings of this study will provide reliable information for health policy makers to develop evidence-based strategies for a high compliance rate. KCT0000803 Date of registration in primary registry: 9 January, 2013.

  5. A qualitative study of secondary distribution of HIV self-test kits by female sex workers in Kenya.

    Directory of Open Access Journals (Sweden)

    Suzanne Maman

    Full Text Available Promoting awareness of serostatus and frequent HIV testing is especially important among high risk populations such as female sex workers (FSW and their sexual partners. HIV self-testing is an approach that is gaining ground in sub-Saharan Africa as a strategy to increase knowledge of HIV status and promote safer sexual decisions. However, little is known about self-test distribution strategies that are optimal for increasing testing access among hard-to-reach and high risk individuals. We conducted a qualitative study with 18 FSW who participated in a larger study that provided them with five oral fluid-based self-tests, training on how to use the tests, and encouragement to offer the self-tests to their sexual partners using their discretion. Women demonstrated agency in the strategies they used to introduce self-tests to their partners and to avoid conflict with partners. They carefully considered with whom to share self-tests, often assessing the possibility for negative reactions from partners as part of their decision making process. When women faced negative reactions from partners, they drew on strategies they had used before to avoid conflict and physical harm from partners, such as not responding to angry partners and forgoing payment to leave angry partners quickly. Some women also used self-tests to make more informed sexual decisions with their partners.

  6. Zagreb Amblyopia Preschool Screening Study: near and distance visual acuity testing increase the diagnostic accuracy of screening for amblyopia.

    Science.gov (United States)

    Bušić, Mladen; Bjeloš, Mirjana; Petrovečki, Mladen; Kuzmanović Elabjer, Biljana; Bosnar, Damir; Ramić, Senad; Miletić, Daliborka; Andrijašević, Lidija; Kondža Krstonijević, Edita; Jakovljević, Vid; Bišćan Tvrdi, Ana; Predović, Jurica; Kokot, Antonio; Bišćan, Filip; Kovačević Ljubić, Mirna; Motušić Aras, Ranka

    2016-02-01

    To present and evaluate a new screening protocol for amblyopia in preschool children. Zagreb Amblyopia Preschool Screening (ZAPS) study protocol performed screening for amblyopia by near and distance visual acuity (VA) testing of 15 648 children aged 48-54 months attending kindergartens in the City of Zagreb County between September 2011 and June 2014 using Lea Symbols in lines test. If VA in either eye was >0.1 logMAR, the child was re-tested, if failed at re-test, the child was referred to comprehensive eye examination at the Eye Clinic. 78.04% of children passed the screening test. Estimated prevalence of amblyopia was 8.08%. Testability, sensitivity, and specificity of the ZAPS study protocol were 99.19%, 100.00%, and 96.68% respectively. The ZAPS study used the most discriminative VA test with optotypes in line as they do not underestimate amblyopia. The estimated prevalence of amblyopia was considerably higher than reported elsewhere. To the best of our knowledge, the ZAPS study protocol reached the highest sensitivity and specificity when evaluating diagnostic accuracy of VA tests for screening. The pass level defined at ≤0.1 logMAR for 4-year-old children, using Lea Symbols in lines missed no amblyopia cases, advocating that both near and distance VA testing should be performed when screening for amblyopia.

  7. Testing the tests--an empirical evaluation of screening tests for the detection of cognitive impairment in aviators.

    Science.gov (United States)

    Stokes, A F; Banich, M T; Elledge, V C

    1991-08-01

    The FAA has expressed concern that flight safety could be compromised by undetected cognitive impairment in pilots due to conditions such as substance abuse, mental illness, and neuropsychological problems. Interest has been shown in the possibility of adding a brief "mini-mental exam," or a simple automated test-battery to the standard flight medical to screen for such conditions. The research reported here involved the empirical evaluation of two "mini-mental exams," two paper-and-pencil test batteries, and a prototype version of an automated screening battery. Sensitivity, specificity, and positive predictive value were calculated for each sub-task in a discriminant study of 54 pilots and 62 individuals from a heterogeneous clinical population. Results suggest that the "mini-mental exams" are poor candidates for a screening test. The automated battery showed the best discrimination performance, in part because of the incorporation of dual-task tests of divided attention performance. These tests appear to be particularly sensitive to otherwise difficult-to-detect cognitive impairments of a mild or subtle nature. The use of an automated battery of tests as a screening instrument does appear to be feasible in principle, but the practical success of a screening program is heavily dependent upon the actual prevalence of cognitive impairment in the medical applicant population.

  8. Avaliação do kit "TF-Test" para o diagnóstico das infecções por parasitas gastrintestinais em ovinos

    Directory of Open Access Journals (Sweden)

    Giuliano Lumina

    2006-08-01

    Full Text Available Este estudo teve como objetivos padronizar o kit TF-Test para a quantificação de ovos de parasitas gastrintestinais de ovinos e compará-lo ao método de Gordon & Whitlock modificado (G&W. Vinte quatro cordeiros confinados foram infectados artificialmente com Haemonchus contortus, durante 12 semanas, até o abate, quando foram colhidas amostras fecais e realizada a identificação e contagem dos parasitas abomasais. Nestes animais, ovos de H. contortus foram detectados em 95,8% das amostras fecais por ambos os testes (P>;0,05. Os coeficientes de correlação (r entre a carga parasitária (CP e os valores de OPG obtidos pelos métodos de G&W e TF-Test foram, respectivamente, de r=0,52 e r=0,51 (dados não transformados e r=0,85 e r=0,87 (dados transformados em log. Outras 100 amostras fecais foram colhidas de ovinos naturalmente infectados. Nas amostras destes animais, os testes G&W e TF-Test propiciaram o diagnóstico de ovos de estrongilídeos em 85% e 86% das amostras, respectivamente (P>;0,05. Pelo TF-Test e pelo G&W, oocistos de Eimeria foram detectados em 33% e em 12% das amostras (P<0,001 e ovos de Strongyloides spp. em 15% e 5% das amostras, respectivamente (P<0,05. Ambos os testes foram precisos para o diagnóstico de estrongilídeos gastrintestinais, porém, o TF-Test foi superior para o diagnóstico de oocistos de Eimeria spp. e de ovos de Strongyloides spp., mas, por outro lado, subestimou o número de ovos de estrongilídeos presente nas amostras.

  9. Evaluation of rapid diagnostic test kits for feline leukemia virus infection using samples from naturally infected cats

    Directory of Open Access Journals (Sweden)

    Jiayou Liu

    2016-09-01

    Full Text Available Objectives Feline leukemia virus (FeLV is a potentially life-threatening oncogenic retrovirus. The p27 viral core protein is produced by the virus in infected feline cells, is found in the cytoplasm in several blood cells and can be free in the serum and plasma. ELISA or particle-based immunoassay are commonly used to detect the presence of the p27 core protein in samples obtained from blood. The objective of this study was to compare the performance of several in-clinic tests: the SNAP Feline Triple Test (IDEXX Laboratories, the WITNESS FeLV-FIV Test (Zoetis and the VetScan Feline FeLV/FIV Rapid Test (Abaxis. Methods The sample population (100 positive, 105 negative samples consisted of serum and plasma samples submitted to IDEXX’s worldwide reference laboratory for feline retrovirus testing. Virus isolation and reverse transcriptase PCR results were not available and so samples were judged to be positive or negative based on the results of the ViraCHEK FeLV (Zoetis microtiter plate assay. Results The percentage of samples positive and negative for FeLV p27 antigen using the three in-clinic tests compared with the ViraCHEK method were as follows: IDEXX Feline Triple (positive 98.0%, negative 100%; Zoetis WITNESS (positive 79.0%, negative 97.1%; Abaxis VetScan (positive 73.0%, negative 97.1%. Conclusions and relevance The SNAP Feline Triple Test demonstrated a high level of agreement for FeLV-positive and FeLV-negative samples when assessed in this model. Results of FeLV assays can vary among tests.

  10. Evaluation of rapid diagnostic test kits for feline leukemia virus infection using samples from naturally infected cats.

    Science.gov (United States)

    Liu, Jiayou; O'Connor, Thomas; Beall, Melissa; Chandrashekar, Ramaswamy; Lappin, Michael

    2016-01-01

    Feline leukemia virus (FeLV) is a potentially life-threatening oncogenic retrovirus. The p27 viral core protein is produced by the virus in infected feline cells, is found in the cytoplasm in several blood cells and can be free in the serum and plasma. ELISA or particle-based immunoassay are commonly used to detect the presence of the p27 core protein in samples obtained from blood. The objective of this study was to compare the performance of several in-clinic tests: the SNAP Feline Triple Test (IDEXX Laboratories), the WITNESS FeLV-FIV Test (Zoetis) and the VetScan Feline FeLV/FIV Rapid Test (Abaxis). The sample population (100 positive, 105 negative samples) consisted of serum and plasma samples submitted to IDEXX's worldwide reference laboratory for feline retrovirus testing. Virus isolation and reverse transcriptase PCR results were not available and so samples were judged to be positive or negative based on the results of the ViraCHEK FeLV (Zoetis) microtiter plate assay. The percentage of samples positive and negative for FeLV p27 antigen using the three in-clinic tests compared with the ViraCHEK method were as follows: IDEXX Feline Triple (positive 98.0%, negative 100%); Zoetis WITNESS (positive 79.0%, negative 97.1%); Abaxis VetScan (positive 73.0%, negative 97.1%). The SNAP Feline Triple Test demonstrated a high level of agreement for FeLV-positive and FeLV-negative samples when assessed in this model. Results of FeLV assays can vary among tests.

  11. Estradiol RIA kit in clinical practice

    International Nuclear Information System (INIS)

    Friedrich, W.; Lisse, K.; Bienert, R.; Flentje, H.; Koerner, H.; Wilken, T.; Akademie der Wissenschaften der DDR, Berlin-Buch. Zentralinstitut fuer Isotopen- und Strahlenforschung)

    1985-01-01

    First clinical experience with a estradiol RIA kit developed in the Central Institute for Isotope- and Radiation Research is reported. The kit was used for the daily control of estradiol level in patients, which were treated within the program for in vitro fertilization and embryo transfer. The time of incubation could be shortened by means of a double antibody technique and by use of a precipitation mixture to 2 h. The intraassay variation is 9.2%, the interassay variation is 15.1%, the recovery rate is 94%. The sensitivity of the test (B 0 -3SD) is about 120 pmol/l. The estradiol RIA kit satisfies clinical requirements. (author)

  12. Screens

    OpenAIRE

    2016-01-01

    This Sixth volume in the series The Key Debates. Mutations and Appropriations in European Film Studies investigates the question of screens in the context both of the dematerialization due to digitalization and the multiplication of media screens. Scholars offer various infomations and theories of topics such as the archeology of screen, film and media theories, contemporary art, pragmatics of new ways of screening (from home video to street screening).

  13. Subjective and objective screening tests for hydroxychloroquine toxicity.

    Science.gov (United States)

    Cukras, Catherine; Huynh, Nancy; Vitale, Susan; Wong, Wai T; Ferris, Fredrick L; Sieving, Paul A

    2015-02-01

    To compare subjective and objective clinical tests used in the screening for hydroxychloroquine retinal toxicity to multifocal electroretinography (mfERG) reference testing. Prospective, single-center, case control study. Fifty-seven patients with a previous or current history of hydroxychloroquine treatment of more than 5 years' duration. Participants were evaluated with a detailed medical history, dilated ophthalmologic examination, color fundus photography, fundus autofluorescence (FAF) imaging, spectral-domain (SD) optical coherence tomography (OCT), automated visual field testing (10-2 visual field mean deviation [VFMD]), and mfERG testing. We used mfERG test parameters as a gold standard to divide participants into 2 groups: those affected by hydroxychloroquine-induced retinal toxicity and those unaffected. We assessed the association of various imaging and psychophysical variables in the affected versus the unaffected group. Fifty-seven study participants (91.2% female; mean age, 55.7±10.4 years; mean duration of hydroxychloroquine treatment, 15.0±7.5 years) were divided into affected (n = 19) and unaffected (n = 38) groups based on mfERG criteria. Mean age and duration of hydroxychloroquine treatment did not differ statistically between groups. Mean OCT retinal thickness measurements in all 9 macular subfields were significantly lower (<40 μm) in the affected group (P < 0.01 for all comparisons) compared with those in the unaffected group. Mean VFMD was 11 dB lower in the affected group (P < 0.0001). Clinical features indicative of retinal toxicity were scored for the 2 groups and were detected in 68.4% versus 0.0% using color fundus photographs, 73.3% versus 9.1% using FAF images, and 84.2% versus 0.0% on the scoring for the perifoveal loss of the photoreceptor ellipsoid zone on SD-OCT for affected and unaffected participants, respectively. Using a polynomial modeling approach, OCT inner ring retinal thickness measurements and Humphrey 10-2 VFMD were

  14. Advantage of using a home-made ELISA kit for detection of Helicobacter pylori infection over commercially imported kits.

    Science.gov (United States)

    Mohammadi, M; Talebkhan, Y; Khalili, G; Mahboudi, F; Massarrat, S; Zamaninia, L; Oghalaei, A

    2008-01-01

    To evaluate a home-made ELISA kit for detection of Helicobacter pylori (Hp) infection and comparison of its immunologic criteria with those of foreign commercial kits. A home-made IgG ELISA kit was developed using soluble antigenic fractions of Hp proteins. Confirmed sera were tested and serological criteria were evaluated through assessment of 199 serum samples. The accuracy, sensitivity and specificity values of home-made kit were 92, 92 and 90.4%, respectively. These immunologic criteria for Trinity kit were 95.2, 95.2 and 95% in comparison with IBL kit (91.3, 92.2 and 88.5%), BIOHIT kit (72.4, 41.6 and 94.1%) and HelicoBlot2.1 (94.2, 93.4 and 100%). Kappa agreement assessment demonstrated that two of the imported ELISA kits had fair to moderate agreement with the home-made kit while the other one had a poor agreement value. Apart from comparable values between the home-made kit and the most efficient imported kit (Trinity) there was significant cost benefit. Therefore, we recommend the home-made kit as a suitable substitution for detection of Hp infection in the Iranian population.

  15. Advantage of using a home-made elisa kit for detection of Helicobacter pylori infection over commercially imported kits

    Directory of Open Access Journals (Sweden)

    Mohammadi M

    2008-01-01

    Full Text Available Purpose: To evaluate a home-made ELISA kit for detection of Helicobacter pylori (Hp infection and comparison of its immunologic criteria with those of foreign commercial kits. Methods: A home-made IgG ELISA kit was developed using soluble antigenic fractions of Hp proteins. Confirmed sera were tested and serological criteria were evaluated through assessment of 199 serum samples. Results: The accuracy, sensitivity and specificity values of home-made kit were 92, 92 and 90.4%, respectively. These immunologic criteria for Trinity kit were 95.2, 95.2 and 95% in comparison with IBL kit (91.3, 92.2 and 88.5%, BIOHIT kit (72.4, 41.6 and 94.1% and HelicoBlot2.1 (94.2, 93.4 and 100%. Kappa agreement assessment demonstrated that two of the imported ELISA kits had fair to moderate agreement with the home-made kit while the other one had a poor agreement value. Conclusions: Apart from comparable values between the home-made kit and the most efficient imported kit (Trinity there was significant cost benefit. Therefore, we recommend the home-made kit as a suitable substitution for detection of Hp infection in the Iranian population.

  16. The Relationship between Preeclampsia and Quadruple Screening Test in Nuliparous

    Directory of Open Access Journals (Sweden)

    Farnaz Zand Vakili

    2017-01-01

    Full Text Available Introduction: Early diagnosis and prediction of preeclampsia needs appropriate obstetric care. Preeclampsia predicting methods are important. This study was designed to determine the correlation between preeclampsia and quadruple screening test in the nulliparous. Materials and Methods:  This case - control study was conducted on 54 pregnant women with preeclampsia (case group and 108 healthy pregnant women (control group who referred to health centers in Sanandaj, Iran. Ultrasonography was performed to determine the gestational age by a radiologist. Maternal serum levels of alpha fetoprotein (AFP, human chorionic gonadotropin (hCG, unconjugated estriol (uE3, and inhibin-A were measured in the second trimester of pregnancy. Data were analyzed using SPSS statistical software and Chi-square test, T-test, sensitivity, specificity, positive and negative predictive values. Results: The results showed that the sensitivity and specificity for the diagnosis of preeclampsia in pregnant women for hCG were 35.2% and 79.6 respectively. These findings for estriol were 20.4% and 88.9%, for inhibin-A were 38.8% and 88% and for alpha fetoprotein were 38.8% and 74.1%. The positive predictive value for hCG, estriol, inhibin-A and alpha fetoprotein were 46.3%, 47.8%, 61.8% and 42.9% respectively. The negative predictive value for hCG, estriol, inhibin-A and alpha fetoprotein were also 71%, 69.1%, 74.2% and 70.8% respectively. Conclusion: There was a relationship between preeclampsia and high levels of inhibin-A and hCG. Further studies on these markers and evaluating their usefulness in the diagnosis and management of preeclampsia are recommended.

  17. Piloting an HIV self-test kit voucher program to raise serostatus awareness of high-risk African Americans, Los Angeles.

    Science.gov (United States)

    Marlin, Robert W; Young, Sean D; Bristow, Claire C; Wilson, Greg; Rodriguez, Jeffrey; Ortiz, Jose; Mathew, Rhea; Klausner, Jeffrey D

    2014-11-26

    Up to half of all new HIV cases in Los Angeles may be caused by the 20-30% of men who have sex with men (MSM) with unrecognized HIV infection. Racial/ethnic minority MSM are at particularly high risk for being sero-unaware and due to stigma and poor healthcare access might benefit from novel private, self-testing methods, such as the recently FDA-approved OraQuick® In-Home HIV Test. From July-November 2013, we undertook a pilot study to examine the feasibility of a voucher program for free OraQuick® tests targeting African American MSM in Los Angeles. We determined feasibility based on: (1) the establishment of a voucher redemption and third-party payment system, (2) the willingness of community-based organizations (CBOs) to disseminate vouchers, and (3) the collection of user demographics, test and linkage-to-care results with an anonymous telephone survey. We partnered with Walgreens® to create a voucher and third-party reimbursement system for free OraQuick® tests. Voucher distribution was divided into two periods. In total, 641 vouchers were supplied to CBOs: 274 (42.7%) went to clients and of those 53 (19.3%) were redeemed. Fifty (18.2%) of the 274 clients were surveyed: 44 (88%) were African American, 39 (78%) reported being likely to repeat voucher use, 44 (88%) reported reviewing pre-test information, and 37 (74%) the post-test information. Three (6%) of 50 survey respondents reported newly testing HIV-positive of whom all (100%) reported seeking medical care. Two withheld their results, both of whom also sought medical care. Developing and partnering with a commercial pharmacy to institute a voucher system to facilitate HIV self-testing with linkage-to-care was feasible. Our findings suggest the voucher program was associated with increasing the identification of new cases of HIV infection with high rates of linkage to care. Expanded research and evaluation of voucher programs for HIV self-test kits among high-risk groups is warranted.

  18. Computerized visuo-spatial memory test as a supplementary screening test for dementia.

    Science.gov (United States)

    Maki, Yohko; Yoshida, Hiroshi; Yamaguchi, Haruyasu

    2010-06-01

    To prepare for a super-aging society, effective dementia screening tests are required. The most salient deficit appearing from the early stages of dementia/Alzheimer's disease (AD) is a deterioration in memory. The Hasegawa Dementia Scale-revised (HDS-R) and the Mini-Mental State Examination (MMSE) are widely used in Japan to screen for dementia. Both place an emphasis on memory function, but neither examines visuo-spatial memory (VSM) function, even though VSM deficits are a sensitive marker for the detection of conversion to dementia. Furthermore, brief tests of VSM that are appropriate for screening have not been standardized. Thus, in the present study, we devised a brief, computer-aided short-term VSM test. Sixty-six aged people were evaluated. Using the Clinical Dementia Rating (CDR), it was found that 29 could be considered normal controls (NC; CDR 0), 10 had mild cognitive impairment (MCI; CDR 0.5), 15 had mild dementia (CDR 1), and 12 had moderate to severe dementia (CDR 2-3). The VSM test estimated how many locations each subject could memorize. Several numbered circles were shown on a monitor and subjects were required to memorize the location of these circles sequentially. After the numbers on the circles on the screen had disappeared, the subjects were required to indicate the circles in ascending order. A touch panel screen was used for this test to make it easier. The HDS-R was applied to subjects with MCI and dementia. The mean (+/-SD) VSM score in subjects with MCI (5.70 +/- 0.96) was significantly lower than that in NC subjects (6.69 +/- 0.82), but significantly higher than that in subjects classified as CDR 1 (4.67 +/- 0.87). There was no significant difference in VSM scores between subjects classified as CDR 1 and CDR 2-3 (3.80 +/- 0.80). There was a moderate significant correlation between VSM and HDS-R scores. In the present study, the VSM test detected differences in VSM function among NC subjects and subjects with MCI and mild dementia. The

  19. Cost-effectiveness of one versus two sample faecal immunochemical testing for colorectal cancer screening

    NARCIS (Netherlands)

    S.L. Goede (Luuk); A.H.C. Roon (Aafke); J.C.I.Y. Reijerink (Jacqueline); A.J. van Vuuren (Hanneke); I. Lansdorp-Vogelaar (Iris); J.D.F. Habbema (Dik); E.J. Kuipers (Ernst); M.E. van Leerdam (Monique); M. van Ballegooijen (Marjolein)

    2013-01-01

    textabstractObjective The sensitivity and specificity of a single faecal immunochemical test (FIT) are limited. The performance of FIT screening can be improved by increasing the screening frequency or by providing more than one sample in each screening round. This study aimed to evaluate if

  20. Does offering prenatal screening influence pregnant women's attitudes regarding prenatal testing?

    NARCIS (Netherlands)

    Kleinveld, J.H.; van den Berg, M.; van Eijk, J.T.; van Vugt, J.M.G.; van der Wal, G.; Timmermans, D.R.M.

    2008-01-01

    Objectives: This study aims to find out whether offering prenatal screening for Down syndrome and neural tube defects influences pregnant women's attitudes toward having a screening test. Methods: Women were randomised into a group that was offered prenatal screening and a group that was not offered

  1. BOOK REVIEW - DOC, PATIENTS' OUTCOME IS IN YOUR HAND. IMPROVE YOUR CLINICAL SKILL WITH DERMATOLOGY CLINICAL SKILL TEST KIT

    Directory of Open Access Journals (Sweden)

    ROHNA RIDZWAN

    2011-01-01

    Full Text Available The author has condensed her almost 30 years of working experience to present dermatology in a uniqueand interesting manner in this book. Unlike a textbook, the reader is guided on common as well as commonly misdiagnosed skin conditions including adverse drug reactions and occupational dermatoses by a series of quizzes which are different from the usual multiple choice type of questions. Responses are scored accordingto their implications on the respondent; for example, the answer will denote that the respondent is either a safe doctor, wasteful of resources or may cause harm to the patient.It will be advantageous for the reader to know basic dermatology but the author has considered readers who may be unfamiliar with the terms by first testing the reader on his knowledge of common dermatological terminologies. The correct answers are given. Useful tips are also provided to differentiate and recognise the skin lesions. With more than 300 coloured images of a wide range of skin conditions collected from local patients, the reader will be able to actively challenge himself in privacy and at his own pace. This book is simple and fun as a learning tool and will be very useful for housemen, postgraduate medical trainees and primary healthcare providers who want to assess their skills in dermatology.

  2. Colon cancer screening

    Science.gov (United States)

    Screening for colon cancer; Colonoscopy - screening; Sigmoidoscopy - screening; Virtual colonoscopy - screening; Fecal immunochemical test; Stool DNA test; sDNA test; Colorectal cancer - screening; Rectal ...

  3. Participation in prenatal screening tests and intentions concerning selective termination in Finnish maternity care

    DEFF Research Database (Denmark)

    Santalahti, P; Hemminki, E; Aro, A R

    1999-01-01

    AIMS: The study examined how prenatal screening tests are presented to women, factors associated with women's participation in screening, their experience of decision-making and intentions concerning pregnancy termination, and hospital data on rates of selective terminations. METHODS: Questionnai......AIMS: The study examined how prenatal screening tests are presented to women, factors associated with women's participation in screening, their experience of decision-making and intentions concerning pregnancy termination, and hospital data on rates of selective terminations. METHODS...... as a routine procedure. Most women (92%) underwent serum screening and most (86%) found the decision to participate or not easy. In almost every aspect of presentation and participation studied, serum and ultrasound screening differed from each other. 85% of respondents to ultrasound screening answered...... in screening and with intentions about selective termination, women's perceptions of lives of the disabled should receive more attention in future studies....

  4. Does population screening for Chlamydia trachomatis raise anxiety among those tested? Findings from a population based chlamydia screening study

    Directory of Open Access Journals (Sweden)

    Low Nicola

    2006-04-01

    Full Text Available Abstract Background The advent of urine testing for Chlamydia trachomatis has raised the possibility of large-scale screening for this sexually transmitted infection, which is now the most common in the United Kingdom. The purpose of this study was to investigate the effect of an invitation to be screened for chlamydia and of receiving a negative result on levels of anxiety, depression and self-esteem. Methods 19,773 men and women aged 16 to 39 years, selected at random from 27 general practices in two large city areas (Bristol and Birmingham were invited by post to send home-collected urine samples or vulvo-vaginal swabs for chlamydia testing. Questionnaires enquiring about anxiety, depression and self-esteem were sent to random samples of those offered screening: one month before the dispatch of invitations; when participants returned samples; and after receiving a negative result. Results Home screening was associated with an overall reduction in anxiety scores. An invitation to participate did not increase anxiety levels. Anxiety scores in men were lower after receiving the invitation than at baseline. Amongst women anxiety was reduced after receipt of negative test results. Neither depression nor self-esteem scores were affected by screening. Conclusion Postal screening for chlamydia does not appear to have a negative impact on overall psychological well-being and can lead to a decrease in anxiety levels among respondents. There is, however, a clear difference between men and women in when this reduction occurs.

  5. Does population screening for Chlamydia trachomatis raise anxiety among those tested? Findings from a population based chlamydia screening study.

    Science.gov (United States)

    Campbell, Rona; Mills, Nicola; Sanford, Emma; Graham, Anna; Low, Nicola; Peters, Tim J

    2006-04-25

    The advent of urine testing for Chlamydia trachomatis has raised the possibility of large-scale screening for this sexually transmitted infection, which is now the most common in the United Kingdom. The purpose of this study was to investigate the effect of an invitation to be screened for chlamydia and of receiving a negative result on levels of anxiety, depression and self-esteem. 19,773 men and women aged 16 to 39 years, selected at random from 27 general practices in two large city areas (Bristol and Birmingham) were invited by post to send home-collected urine samples or vulvo-vaginal swabs for chlamydia testing. Questionnaires enquiring about anxiety, depression and self-esteem were sent to random samples of those offered screening: one month before the dispatch of invitations; when participants returned samples; and after receiving a negative result. Home screening was associated with an overall reduction in anxiety scores. An invitation to participate did not increase anxiety levels. Anxiety scores in men were lower after receiving the invitation than at baseline. Amongst women anxiety was reduced after receipt of negative test results. Neither depression nor self-esteem scores were affected by screening. Postal screening for chlamydia does not appear to have a negative impact on overall psychological well-being and can lead to a decrease in anxiety levels among respondents. There is, however, a clear difference between men and women in when this reduction occurs.

  6. 40 CFR 799.9355 - TSCA reproduction/developmental toxicity screening test.

    Science.gov (United States)

    2010-07-01

    ... developmental defects should not be used. Healthy virgin animals, not subjected to previous experimental..., except legal holidays. (1) OECD (1995). Reproduction/Developmental Toxicity Screening Test, OECD 421...

  7. Comparison of Three Different Commercial Kits for the Human Papilloma Virus Genotyping.

    Science.gov (United States)

    Lim, Yong Kwan; Choi, Jee-Hye; Park, Serah; Kweon, Oh Joo; Park, Ae Ja

    2016-11-01

    High-risk type human papilloma virus (HPV) is the most important cause of cervical cancer. Recently, real-time polymerase chain reaction and reverse blot hybridization assay-based HPV DNA genotyping kits are developed. So, we compared the performances of different three HPV genotyping kits using different analytical principles and methods. Two hundred positive and 100 negative cervical swab specimens were used. DNA was extracted and all samples were tested by the MolecuTech REBA HPV-ID, Anyplex II HPV28 Detection, and HPVDNAChip. Direct sequencing was performed as a reference method for confirming high-risk HPV genotypes 16, 18, 45, 52, and 58. Although high-level agreement results were observed in negative samples, three kits showed decreased interassay agreement as screening setting in positive samples. Comparing the genotyping results, three assays showed acceptable sensitivity and specificity for the detection of HPV 16 and 18. Otherwise, various sensitivities showed in the detection of HPV 45, 52, and 58. The three assays had dissimilar performance of HPV screening capacity and exhibited moderate level of concordance in HPV genotyping. These discrepant results were unavoidable due to difference in type-specific analytical sensitivity and lack of standardization; therefore, we suggested that the efforts to standardization of HPV genotyping kits and adjusting analytical sensitivity would be important for the best clinical performance. © 2016 Wiley Periodicals, Inc.

  8. Production of sestamibi kit for nuclear imaging

    Energy Technology Data Exchange (ETDEWEB)

    Abdullah, Hakim; Zakaria, Ahmad; Yaacob, Hadzri; Ramli, Jamaluddin [Universiti Sains Malaysia, Kelantan (Malaysia). School of Medical Sciences

    1997-12-01

    One of the research projects undertaken during the implementation of the IAEA Technical Assistance Cooperation Program in our department was inhouse production of sestamibi (MIBI) kit to be labelled with Tc99m pertechnetate for myocardial studies and for malignant tumor imaging. 100 mg raw materials of sestamibi was supplied by IAEA and the kit was prepared based on Janoki recipe. Using 6 mg MIBI, 192 mg glycine, 3.6 mg stannous chloride, 62.4 mg Na sub 4 Po sub 4 and 24 mg cysteine we have prepared 24 vials of MIBI kit under sterile condition and stored in the freezer at -70 degree C. The sterility of the kit was confirmed by microbiological test using cultured method. The stability test was done by labelling the kit with Tc-99m pertechnetate at day 1, 3, 7, 30 and 60 days after kit preparation. Using two system butanone and saline with ITLC the labelling efficiency of Tc-99m (MIBI) was found to be more than 90% in each case. The labelling efficiency was found to maintain at 90% up to 24 hours post reconstitution at room temperature. Biodistribution study was carried out by administering Tc-99m (MIBI) to mice intravenously at the dosage of IOO {mu} Ci per 20 gm body weight. The mice were sacrificed at 3 hours and 24 hours after the dose administration. Blood, heart, lung, intestine, kidney and stomach samples were obtained, weighed and measured for radioactivity using gamma well counter. The data showed that after 3 hours about 60% of the injected dose accumulated in the intestine which was in agreement with IAEA standard. At 24 hours the amount in the heart still remained about 25% of the 3 hour uptake. In house production of MIBI kit is easy, fast and cost effective. The data suggested that the quality of our kit was good enough to be used for further animal research and clinical trials.

  9. Self-Sampling for Human Papillomavirus Testing: Increased Cervical Cancer Screening Participation and Incorporation in International Screening Programs

    Science.gov (United States)

    Gupta, Sarah; Palmer, Christina; Bik, Elisabeth M.; Cardenas, Juan P.; Nuñez, Harold; Kraal, Laurens; Bird, Sara W.; Bowers, Jennie; Smith, Alison; Walton, Nathaniel A.; Goddard, Audrey D.; Almonacid, Daniel E.; Zneimer, Susan; Richman, Jessica; Apte, Zachary S.

    2018-01-01

    In most industrialized countries, screening programs for cervical cancer have shifted from cytology (Pap smear or ThinPrep) alone on clinician-obtained samples to the addition of screening for human papillomavirus (HPV), its main causative agent. For HPV testing, self-sampling instead of clinician-sampling has proven to be equally accurate, in particular for assays that use nucleic acid amplification techniques. In addition, HPV testing of self-collected samples in combination with a follow-up Pap smear in case of a positive result is more effective in detecting precancerous lesions than a Pap smear alone. Self-sampling for HPV testing has already been adopted by some countries, while others have started trials to evaluate its incorporation into national cervical cancer screening programs. Self-sampling may result in more individuals willing to participate in cervical cancer screening, because it removes many of the barriers that prevent women, especially those in low socioeconomic and minority populations, from participating in regular screening programs. Several studies have shown that the majority of women who have been underscreened but who tested HPV-positive in a self-obtained sample will visit a clinic for follow-up diagnosis and management. In addition, a self-collected sample can also be used for vaginal microbiome analysis, which can provide additional information about HPV infection persistence as well as vaginal health in general. PMID:29686981

  10. Comparison of the automated vision screening test to the Snellen test.

    Science.gov (United States)

    Gofin, R; Falk, M

    1991-03-01

    The comparison of an automatic vision screening machine using the Landolt rings and the usual Snellen Chart was carried out among 123 second grade and 149 fifth grade students in an elementary school in Jerusalem. The sensitivity of the test for a cut-off point of greater than or equal to 6/12 according to the Snellen test was 41.7% (CI = 16.5-71.4) and the specificity was 86.5% (CI 78.1-92.2) for second graders. For fifth graders the values were 50.0% (CI = 20.1-79.9) and 90.6% (CI 83.7-94.8) respectively. Diagnosis by a specialist decreased the number of 'false negatives' and confirmed the pathological cases. The automatic test was well accepted by the children. Though more time is needed for assessment using the automatic test, its advantage is that no professional staff are required.

  11. Comparação de kits ELISA® comerciais para anticorpos no soro e leite com um teste coproparasitológico em bovinos naturalmente infectados por Fasciola hepatica

    Directory of Open Access Journals (Sweden)

    Cíntia das C. Bernardo

    2013-01-01

    Full Text Available A fasciolose é uma enfermidade causada por um trematoda que acomete o fígado principalmente de ruminantes domésticos, podendo parasitar o homem e seu diagnóstico é realizado rotineiramente por exames coproparasitológicos. O objetivo do presente estudo foi comparar kits comerciais de ELISA para anticorpos no soro e leite com um teste coproprarasitológico em bovinos naturalmente infectados por Fasciola hepatica. Foram coletadas amostras de fezes (92 sangue (92 e leite (43 de bovinos provenientes de propriedades de gado leiteiro do município de Jerônimo Monteiro, sul do Estado do Espírito Santo. As amostras de fezes coletadas foram processadas pela técnica de sedimentação fecal para ovos de F. hepatica, utilizada como padrão ouro para as análises. Amostras de sangue e de leite foram processadas segundo a orientação do fabricante dos respectivos Kits ELISA comerciais testados. Utilizou-se o c² de McNemar para comparação estatística e calcularam-se a sensibilidade e especificidade, valores preditivos e kappa. Os resultados obtidos mostraram que as frequências de positividade pelo uso dos kits ELISA comerciais de soro e de leite diferiram significativamente (p<0,0001 em relação ao exame coproparasitológico. A sensibilidade dos Kits foi de 100%, porém possuíram baixa especificidade, 42,85 e 30% para o soro e leite respectivamente. O coeficiente de kappa mostrou concordância sofrível para os testes de soro (0,33 e de leite (0,21. Os valores preditivos positivos dos kits para soro e leite foram, respectivamente, 44,61 e 38,23% e, os valores preditivos negativos de 100% para ambos os testes. Apesar da maior sensibilidade dos kits ELISA comerciais e, destes apresentarem diferença em relação ao exame coproparasitológico na detecção dos animais positivos para F. hepatica, a escolha de um teste diagnóstico deve considerar o custo benefício. Quando se trata da presença de parasitismo em rebanhos, o tratamento é aplicado

  12. Iodobell in vivo kits for labelling with 123I or 131I

    International Nuclear Information System (INIS)

    Koernyei, J.; Horvath, M.; Pszota, A.; Lakatos, M.; Szirtes, L.

    1988-01-01

    Iodobell in vivo kits provide an easy and fast method for 'on the spot' radioiodination with 123 I (or 131 I). Until now three kits have been developed in the Institute of Isotopes Budapest, the heptadecanoic acid, the hippurate and the MIBG kits. From these, the heptadecanoic acid kit is being tested in humans in Hungary, the other two are under the registration procedure. The Iodobell in vivo kits may contribute to the application of 123 I radioisotope in Hungary. (orig.)

  13. The problem of false-positive human papillomavirus DNA tests in cervical screening

    DEFF Research Database (Denmark)

    Rebolj, Matejka; Pribac, Igor; Frederiksen, Maria Eiholm

    2013-01-01

    Human Papillomavirus (HPV) testing has been extensively studied in randomized controlled trials of primary cervical screening. Based on encouraging results concerning its high detection rates and a high negative predictive value for high-grade cervical intraepithelial neoplasia (CIN), HPV testing...... will probably replace cytology in future primary cervical screening. However, HPV testing is associated with more frequent false-positive tests compared to cytology. False-positive tests are defined as positive screening tests which are not subsequently confirmed with high-grade CIN. Several authors have...

  14. Onboard screening dockside testing as a new means of managing paralytic shellfish poisoning risks in federally closed waters

    Science.gov (United States)

    DeGrasse, Stacey; Conrad, Stephen; DiStefano, Paul; Vanegas, Camilo; Wallace, David; Jensen, Pete; Hickey, J. Michael; Cenci, Florence; Pitt, Jaclyn; Deardorff, Dave; Rubio, Fernando; Easy, Dorothy; Donovan, Mary Anne; Laycock, Maurice; Rouse, Debbie; Mullen, John

    2014-05-01

    Paralytic shellfish poisoning (PSP) is the foodborne intoxication associated with the consumption of seafood contaminated with naturally occurring neurotoxins known as paralytic shellfish toxins. To protect public health from this potentially fatal syndrome, harvesting closures are implemented when toxins exceed the regulatory action level. Traditional monitoring programs established by state shellfish authorities allow for timely closures in state waters with minimal negative impacts on industry. However, such monitoring programs are not feasible in federal offshore waters given their distance from shore and the range of their spatial coverage. Thus innovative management strategies were investigated for these offshore resources. Georges Bank, an offshore resource with an estimated market value of more than 3 billion in Atlantic surfclams and ocean quahogs, has been closed to harvesting following a temporary ban in 1989 and a subsequent indefinite closure in 1990 due to the risk of PSP. As a means of managing this risk and allowing harvest of safe shellfish from this important resource, the Onboard Screening Dockside Testing Protocol (referred to as the Protocol) was developed by the US Food and Drug Administration (FDA), National Marine Fisheries Service (NMFS), state shellfish control authorities, and industry. The Protocol, which sets forth control measures to ensure product safety and public health protection, was endorsed by the Interstate Shellfish Sanitation Conference (ISSC) for pilot testing. Briefly, the pilot study Protocol required that (1) the fishing vessel receive a permit from NMFS to harvest in closed waters, (2) a miniμm of five shellfish samples per intended harvest lot be tested for PSP toxins onboard, and (3) harvesting only occur when the samples tested from the intended fishing area are negative using the Jellett Rapid Tests or Abraxis Shipboard ELISA kits. Finally, product landed under the Protocol was confirmed to be safe for consumption

  15. Validity of Forced Eyelid Closure Test: A Novel Clinical Screening Test for Ocular Myasthenia Gravis.

    Science.gov (United States)

    Apinyawasisuk, Supanut; Zhou, Xinkai; Tian, Jack J; Garcia, Giancarlo A; Karanjia, Rustum; Sadun, Alfredo A

    2017-09-01

    Forced eyelid closure test (FECT) is a clinical screening test developed from the original Cogan lid twitch (CLT) sign to assist in the diagnosis of ocular myasthenia gravis (OMG), We evaluated the sensitivity and specificity of FECT compared with CLT and benchmarked to standard diagnostic tests. This study was a retrospective chart review of 48 patients using electronic medical records of those that presented with ptosis and/or diplopia at Doheny Eye Institute, University of California, Los Angeles between February 2015 and April 2016. Patients without FECT testing were excluded. FECT and CLT results, and final diagnosis were recorded. To perform FECT, the patient was asked to squeeze his or her eyelids shut for 5-10 seconds then open quickly and fixate in primary position. The excessive upward overshoot of eyelids movement indicated a positive FECT. The test was performed by a neuro-ophthalmologist before establishing the diagnosis. Patients who had equivocal test results and/or inconclusive final diagnosis were excluded. Of the 48 patients studied, 18 patients (37.5%) had positive FECT; 15 of whom had a final diagnosis of OMG (83.3%). Of the 30 patients with negative FECT, 1 had OMG (3.3%). Of the 48 patients, 35 patients also had a documented CLT result (72.9%). CLT was positive in 11 of these 35 patients (31.4%), and 9 of these 11 had OMG (81.8%). Of the 24 patients with negative CLT, 2 of them had OMG (8.3%). Sensitivity and specificity of FECT were 94% and 91% (joint 95% confidence region: sensitivity × specificity = [0.70, 1] × [0.75, 1]). The relative true-positive fraction (rTPF) between FECT and CLT was 1.15; the relative false-positive fraction was 1.31. FECT is a simple clinical screening test with good sensitivity and specificity for OMG.

  16. Risk-benefit analysis for mass screening of breast cancer utilizing mammography as a screening test

    International Nuclear Information System (INIS)

    Iinuma, T.A.; Tateno, Yukio

    1989-01-01

    Incidence of breast cancers in Japanese women is increasing steadily. Mass screening of breast cancer was started in Japan under auspices of Adult Health Promotion Act of the Japanese Government from 1987. As the first screening method, the palpation of breasts is employed at present, but it is expected to be replaced by the mammography. In this report, the risk-benefit analysis is presented between risk of breast carcinogenesis due to radiation and benefit of mass screening of breast cancer. The benefit of mass screening is taken as the net elongation of average life expectancy of women due to survival from breast cancers. The risk of mammography is taken as the net loss of average life expectancy of women due to breast carcinogenesis. In the latter, the latency time and plateau period of radiation carcinogenesis were taken into consideration in the calculation. The results show that the ages at which the benefit and risk become equal are between 30 and 35 years old when dose equivalent of mammography is between 10 and 20 mSv, that are conventionally used. However, the critical age will be reduced to 20 years old if the dose equivalent becomes 1 mSv. Therefore, it is strongly recommended that a low dose mammographic system should be developed in order to achieve 1 mSv for the mass screening of breast cancer of Japanese women. In author's opinion, this is quite feasible by employing a new digital radiography with imaging plate. (author)

  17. Experiences with a self-test for Dutch breast screening radiologists: lessons learnt

    NARCIS (Netherlands)

    Timmers, J. M. H.; Verbeek, A. L. M.; Pijnappel, R. M.; Broeders, M. J. M.; den Heeten, G. J.

    2014-01-01

    To evaluate a self-test for Dutch breast screening radiologists introduced as part of the national quality assurance programme. A total of 144 radiologists were invited to complete a test-set of 60 screening mammograms (20 malignancies). Participants assigned findings such as location, lesion type

  18. 77 FR 4544 - CPSC Symposium on Phthalates Screening and Testing Methods

    Science.gov (United States)

    2012-01-30

    ... Screening and Testing Methods AGENCY: Consumer Product Safety Commission. ACTION: Notice. SUMMARY: The... symposium on phthalates screening and testing methods. The symposium will be held at the CPSC's National... submit comments, identified by Docket No. CPSC-2012-0008, by any of the following methods: Electronic...

  19. Willingness to take a screening test for colorectal cancer: a community-based survey in Malaysia.

    Science.gov (United States)

    Naing, Cho; Jun, Yip Kar; Yee, Wai Mun; Waqiyuddin, Syazana J D B T; Lui, Lau Chiew; Shaung, Ooi Yin; Haw, Fong Jenn

    2014-03-01

    The aims of the study were (i) to determine the knowledge and perceptions of colorectal cancer (CRC), (ii) to explore the willingness of the study population to take a screening test for CRC, and (iii) to identify factors affecting the willingness to take a screening test for CRC. A cross-sectional survey was carried out in a semiurban town in Malaysia using a pretested structured questionnaire. Descriptive statistics were determined for all important variables. A binary logistic regression model was introduced to identify independent predictors of the willingness to take a screening test. Factors influencing willingness were explored according to the constructs of the health belief model. Of the 256 respondents who had heard about CRC, the majority were aware of altered bowel habits (67.3%) or the presence of blood in stool or rectal bleeding (63.4%) as the warning symptoms. Although 38% of the respondents knew of colonoscopy as the screening test, 22% were not aware of any screening test for CRC. A majority (77.4%) showed willingness to take a screening test for CRC. In the multivariate analysis, 'having family or friends with history of CRC' and 'self-perceived risk' were the two significant variables for predicting the acceptance of CRC screening among the study population. Findings suggested that the respondents' knowledge of the CRC screening test was inadequate, albeit a high proportion expressed their intention to take screening tests. Health education on the CRC addressing available screening tests and the benefits of early screening for CRC should be scaled up.

  20. KIT mutation analysis in mast cell neoplasms

    DEFF Research Database (Denmark)

    Arock, M; Sotlar, K; Akin, C

    2015-01-01

    mutations in patients with mastocytosis at diagnosis and during follow-up with sufficient precision and sensitivity in daily practice. In addition, we provide recommendations for sampling and storage of diagnostic material as well as a robust diagnostic algorithm. Using highly sensitive assays, KIT D816V...... can be detected in peripheral blood leukocytes from most patients with systemic mastocytosis (SM) that is a major step forward in screening and SM diagnosis. In addition, the KIT D816V allele burden can be followed quantitatively during the natural course or during therapy. Our recommendations should...... greatly facilitate diagnostic and follow-up investigations in SM in daily practice as well as in clinical trials. In addition, the new tools and algorithms proposed should lead to a more effective screen, early diagnosis of SM and help to avoid unnecessary referrals....

  1. Abnormal ovarian cancer screening test result: women's informational, psychological and practical needs.

    Science.gov (United States)

    Ryan, Patricia Y; Graves, Kristi D; Pavlik, Edward J; Andrykowski, Michael A

    2007-01-01

    Considerable effort has been devoted to the identification of cost-effective approaches to screening for ovarian cancer (OC). Transvaginal ultrasound (TVS) is one such screening approach. Approximately 5-7% of routine TVS screening tests yield abnormal results. Some women experience significant distress after receipt of an abnormal TVS screening test. Four focus groups provided in-depth, qualitative data regarding the informational, psychological, and practical needs of women after the receipt of an abnormal TVS result. Through question and content analytic procedures, we identified four themes: anticipation, emotional response, role of the screening technician, and impact of prior cancer experiences. Results provide initial guidance toward development of interventions to promote adaptive responses after receipt of an abnormal cancer screening test result.

  2. The King–Devick test for sideline concussion screening in collegiate football

    Directory of Open Access Journals (Sweden)

    Danielle F. Leong

    2015-04-01

    Conclusions: The data show worsening of K–D test scores following concussion further supporting utility of the K–D test as an objective, reliable and effective sideline visual screening tool to help identify athletes with concussion.

  3. Commercial herbal medicines used as African traditional medicines: Ngoma Herbal Tonic Immune Booster interferes with a rapid urine drug screening test.

    Science.gov (United States)

    Mothibe, M E; Osuch, E; Kahler-Venter, C P

    2017-08-25

    The prevalent use of African traditional medicine by the general public has been reported. With commercialisation and marketing, some of the herbal medicines (HMs) used are readily available over the counter, most of them promoted as immune boosters. These commercial HMs have not been taken through clinical trials and other tests that would validate their composition and safety, and other properties such as their effect on laboratory diagnostic tests. To investigate the cross-reactivity of selected HMs with commonly tested drugs of abuse (DoA) using a qualitative rapid urinalysis assay. The six HMs selected were bought from local pharmacies. A rapid urinalysis screening test was performed with the Instant View Multi-Drug of Abuse Test kit from Labstix Diagnostics. Drug-free urine (DFU) was pooled from samples donated by healthy volunteers. Urine samples that had tested positive for DoA were obtained from a pharmacology laboratory. Aliquots of the urine samples were spiked with the HMs in neat and diluted form, and tested at various time intervals. The results for the DFU samples spiked with the HMs remained negative. There were no significant changes in pH or specific gravity of the samples. The results of samples that had tested positive for tetrahydrocannabinol (THC) were not altered by five of the HMs when spiked at 40% v/v. The HM Ngoma Herbal Tonic Immune Booster caused false-negative results for the THC test. An important finding is that the herbal mixture Ngoma Herbal Tonic Immune Booster caused false-negative results for the cannabinoid screening test. It adds to the list of substances that may be potential adulterants of urine for screening tests.

  4. Screening for gestational diabetes: examining a breakfast meal test

    African Journals Online (AJOL)

    In current literature both universal and selective screening are still ... One of the central issues that has received less attention is the ... The recorded information included the type of food, ... Body mass index (BMI) at booking > 40 kg/m2.

  5. Mammography and Other Screening Tests for Breast Problems

    Science.gov (United States)

    ... young age; and a history of high-risk breast biopsy results. Women without these risk factors are at ... on when and how often you will have breast screening. Glossary Benign: Not cancer. Biopsy: A minor surgical procedure to remove a small ...

  6. Validating a dance-specific screening test for balance: preliminary results from multisite testing.

    Science.gov (United States)

    Batson, Glenna

    2010-09-01

    Few dance-specific screening tools adequately capture balance. The aim of this study was to administer and modify the Star Excursion Balance Test (oSEBT) to examine its utility as a balance screen for dancers. The oSEBT involves standing on one leg while lightly targeting with the opposite foot to the farthest distance along eight spokes of a star-shaped grid. This task simulates dance in the spatial pattern and movement quality of the gesturing limb. The oSEBT was validated for distance on athletes with history of ankle sprain. Thirty-three dancers (age 20.1 +/- 1.4 yrs) participated from two contemporary dance conservatories (UK and US), with or without a history of lower extremity injury. Dancers were verbally instructed (without physical demonstration) to execute the oSEBT and four modifications (mSEBT): timed (speed), timed with cognitive interference (answering questions aloud), and sensory disadvantaging (foam mat). Stepping strategies were tracked and performance strategies video-recorded. Unlike the oSEBT results, distances reached were not significant statistically (p = 0.05) or descriptively (i.e., shorter) for either group. Performance styles varied widely, despite sample homogeneity and instructions to control for strategy. Descriptive analysis of mSEBT showed an increased number of near-falls and decreased timing on the injured limb. Dancers appeared to employ variable strategies to keep balance during this test. Quantitative analysis is warranted to define balance strategies for further validation of SEBT modifications to determine its utility as a balance screening tool.

  7. Evaluation of commercial ELISA kits for detection of antibodies against bovine atypical pestivirus

    DEFF Research Database (Denmark)

    Larska, Magdalena; Polak, Mirosław P.; Uttenthal, Åse

    A group of emerging bovine pestiviruses becomes a possible threat to Bovine Viral diarrhea virus (BVDV) control and eradication programs in the countries of their origin and in the new continents due to the lack of validated detection methods. The use of ELISA kits may be acheaper, time saving...... and less laborious option allowing screening for antibodies in large populations. Since test specific for emerging and new BVDV strains are still under preparation, the purpose of this work was to evaluate available BVDV antibody ELISA assays for their ability to detect antibodies against Hobi-like viruses....... Analysis of a panel of sera obtained from calves experimentally inoculated with Hobi-like virus (isolated from a calf from Thailand) and BVDV type 1 strain using five different ELISA kits in comparison to neutralization test was performed. The specificity and sensitivity of the tests depended greatly...

  8. Personalized Thematic Kits

    Science.gov (United States)

    Bontrager, Sharon

    2010-01-01

    Teaching Spanish at the K-5 level is a passion of mine, and the author would like to share some of the practical applications that she finds most rewarding and effective. She has found enthusiastic response to the creation of detailed language learning kits that are rooted in storytelling, but expanded to include home-made board games,…

  9. World Disarmament Kit.

    Science.gov (United States)

    Woito, Robert, Ed.

    This kit presents a comprehensive introduction for students to arms control and disarmament issues. Included are copies of published and unpublished articles for each topic. Section I provides a self-survey to enable students to assess their own attitudes, values, and knowledge. The survey poses questions for which students select one of several…

  10. IODOBELL in vivo kits for in situ labelling with iodine

    International Nuclear Information System (INIS)

    Koernyei, Jozsef; Lakatos, Mihaly; Kecskes, Ferenc; Mahunka, Imre; Mikecz, Pal; Ando, Laszlo

    1988-01-01

    A system of in vivo kits called IODOBELL was developed in the Institute of Isotopes, Budapest. The production of hepatodecanoic acid for cardiology, iodo-hippuranic acid for kidney diagnostics and a special pharmaceutical, IODOBELL-MIGB for the indication of feochromocitoma and neuroblastoma is reported. The heptadecanoic acid kit is under human examination, the other two are to be tested in the near future. IODOBELL kits contribute to the wider use of 123 I in Hungary. (author) 6 refs

  11. Will gay and bisexually active men at high risk of infection use over-the-counter rapid HIV tests to screen sexual partners?

    Science.gov (United States)

    Carballo-Diéguez, Alex; Frasca, Timothy; Dolezal, Curtis; Balan, Ivan

    2012-01-01

    The Food and Drug Administration may license OraQuick™, a rapid HIV test, for over-the-counter (OTC) sale. This study investigated whether HIV-uninfected, non-monogamous, gay and bisexual men who never or rarely use condoms would use the test with partners as a harm-reduction approach. Sixty participants responded to two computer-assisted self-interviews, underwent an in-depth interview, and chose whether to test themselves with OraQuick. Over 80% of the men said they would use the kit to test sexual partners or themselves if it became available OTC. Most participants understood that antibody tests have a window period in which the virus is undetectable, yet saw advantages to using the test to screen partners; 74% tested themselves in our offices. Participants offered several possible strategies to introduce the home-test idea to partners, frequently endorsed mutual testing, and highlighted that home testing could stimulate greater honesty in serostatus disclosure. Participants drew distinctions between testing regular versus occasional partners. Non-monogamous men who have sex with men, who never or rarely use condoms, may nevertheless seek to avoid HIV. Technologies that do not interfere with sexual pleasure are likely to be used when available. Studies are needed to evaluate the advantages and disadvantages of using OTC rapid HIV tests as one additional harm-reduction tool.

  12. 49 CFR 173.161 - Chemical kits and first aid kits.

    Science.gov (United States)

    2010-10-01

    ... 49 Transportation 2 2010-10-01 2010-10-01 false Chemical kits and first aid kits. 173.161 Section... Class 7 § 173.161 Chemical kits and first aid kits. (a) Chemical kits and First aid kits must conform to... 10 kg. (b) Chemical kits and First aid kits are excepted from the specification packaging...

  13. Build an Emergency Preparedness Kit

    Science.gov (United States)

    ... In addition to the items listed above, a vehicle kit should include: -fire extinguisher. -booster cables and tow rope. -compass and road maps. -shovel. -tire repair kit and pump. -extra clothing to keep dry. - ...

  14. ISS Expedition 08 Press Kit

    Data.gov (United States)

    National Aeronautics and Space Administration — Press kit for ISS mission Expedition 08 from 10/2003-04/2004. Press kits contain information about each mission overview, crew, mission timeline, benefits, and media...

  15. Development and validation of a new cognitive screening test: The Hong Kong Brief Cognitive Test (HKBC).

    Science.gov (United States)

    Chiu, Helen F K; Zhong, Bao-Liang; Leung, Tony; Li, S W; Chow, Paulina; Tsoh, Joshua; Yan, Connie; Xiang, Yu-Tao; Wong, Mike

    2018-07-01

    To develop and examine the validity of a new brief cognitive test with less educational bias for screening cognitive impairment. A new cognitive test, Hong Kong Brief Cognitive Test (HKBC), was developed based on review of the literature, as well as the views of an expert panel. Three groups of subjects aged 65 or above were recruited after written consent: normal older people recruited in elderly centres, people with mild NCD (neurocognitive disorder), and people with major NCD. The brief cognitive test, Mini-Mental State Examination (MMSE) and Montreal Cognitive Assessment Scale (MoCA), were administered to the subjects. The performance of HKBC in differentiating subjects with major NCD, mild NCD, and normal older people were compared with the clinical diagnosis, as well as the MMSE and MoCA scores. In total, 359 subjects were recruited, with 99 normal controls, 132 subjects with major NCD, and 128 with mild NCD. The mean MMSE, MoCA, and HKBC scores showed significant differences among the 3 groups of subjects. In the receiving operating characteristic curve analysis of the HKBC in differentiating normal subjects from those with cognitive impairment (mild NCD + major NCD), the area under the curve was 0.955 with an optimal cut-off score of 21/22. The performances of MMSE and MoCA in differentiating normal from cognitively impaired subjects are slightly inferior to the HKBC. The HKBC is a brief instrument useful for screening cognitive impairment in older adults and is also useful in populations with low educational level. Copyright © 2018 John Wiley & Sons, Ltd.

  16. Autofluorescence: A screening test for mycotic infection in tissues

    Directory of Open Access Journals (Sweden)

    Rao Shalinee

    2008-04-01

    Full Text Available Fungal infection is a major health concern as the clinical features are not very distinctive. Lack of rapid diagnostic techniques results in delay in diagnosis, which may even culminate in a fatal outcome. The fact that many pathogenic fungal organisms autofluoresce in hematoxylin and eosin (H and E-stained sections under ultraviolet illumination led us to evaluate the role of autofluorescence as a rapid screening technique for fungal infections. The aim of the present study was to assess the value of autofluorescence as a screening method for detecting fungi on tissue sections and to compare the results of autofluorescence with conventional histochemical stains for fungi. Hematoxylin and eosin-stained slides of mycotic lesions were examined under fluorescent microscope and the findings were compared with results of Gomori′s methenamine silver and periodic acid-Schiff stains. We found fungal autofluorescence in 63 out of 64 cases studied, with a sensitivity of 97.8% and specificity of 100% in comparison with fungal stains. This was statistically significant (P < 0.05. We conclude that autofluorescence can be used as a rapid screening method for identification of fungi in tissue sections as it does not require any other specialized staining procedure

  17. Personal Computer-less (PC-less) Microcontroller Training Kit

    Science.gov (United States)

    Somantri, Y.; Wahyudin, D.; Fushilat, I.

    2018-02-01

    The need of microcontroller training kit is necessary for practical work of students of electrical engineering education. However, to use available training kit not only costly but also does not meet the need of laboratory requirements. An affordable and portable microcontroller kit could answer such problem. This paper explains the design and development of Personal Computer Less (PC-Less) Microcontroller Training Kit. It was developed based on Lattepanda processor and Arduino microcontroller as target. The training kit equipped with advanced input-output interfaces that adopted the concept of low cost and low power system. The preliminary usability testing proved this device can be used as a tool for microcontroller programming and industrial automation training. By adopting the concept of portability, the device could be operated in the rural area which electricity and computer infrastructure are limited. Furthermore, the training kit is suitable for student of electrical engineering student from university and vocational high school.

  18. Low knowledge and anecdotal use of unauthorized online HIV self-test kits among attendees at a street-based HIV rapid testing programme in Spain.

    Science.gov (United States)

    Belza, M José; Figueroa, Carmen; Rosales-Statkus, M Elena; Ruiz, Mónica; Vallejo, Fernando; de la Fuente, Luis

    2014-08-01

    The objectives of this study were to estimate the percentage of potential users who know that unauthorized HIV self-tests can be purchased online and the percentage of those who have already used them, and to determine socio-demographic and behavioural correlates. A self-administered questionnaire was employed to collect data from attendees at a street-based HIV testing programme. Logistic regression for rare events was performed. Of the 3340 participants, 5.3% (95% confidence interval (CI) 4.5-6.0%) had knowledge of self-tests being sold online and 7.5% (95% CI 6.6-8.5%) thought they existed but had never seen them; only 0.6% (95% CI 0.3-0.9%) had ever used one. Knowing that self-tests are sold online (odds ratio (OR) 3.6, 95% CI 2.4-5.4) and using them (OR 7.3, 95% CI 2.2-23.8) were associated with having undergone more than two previous HIV tests. Use was also associated with being neither Spanish nor Latin American (OR 3.8, 95% CI 1.2-12.0) and with having a university degree (OR 0.2, 95% CI 0.1-0.7). At the time of the study, the impact on the population of issues related to the use of unauthorized tests was very low. However, media coverage following the approval of self-testing in the USA might have changed the situation. Copyright © 2014 The Authors. Published by Elsevier Ltd.. All rights reserved.

  19. The characterization of four gene expression analysis in circulating tumor cells made by Multiplex-PCR from the AdnaTest kit on the lab-on-a-chip Agilent DNA 1000 platform.

    Science.gov (United States)

    Škereňová, Markéta; Mikulová, Veronika; Čapoun, Otakar; Zima, Tomáš

    2016-01-01

    Nowadays, on-a-chip capillary electrophoresis is a routine method for the detection of PCR fragments. The Agilent 2100 Bioanalyzer was one of the first commercial devices in this field. Our project was designed to study the characteristics of Agilent DNA 1000 kit in PCR fragment analysis as a part of circulating tumour cell (CTC) detection technique. Despite the common use of this kit a complex analysis of the results from a long-term project is still missing. A commercially available Agilent DNA 1000 kit was used as a final step in the CTC detection (AdnaTest) for the determination of the presence of PCR fragments generated by Multiplex PCR. Data from 30 prostate cancer patients obtained during two years of research were analyzed to determine the trueness and precision of the PCR fragment size determination. Additional experiments were performed to demonstrate the precision (repeatability, reproducibility) and robustness of PCR fragment concentration determination. The trueness and precision of the size determination was below 3% and 2% respectively. The repeatability of the concentration determination was below 15%. The difference in concentration determination increases when Multiplex-PCR/storage step is added between the two measurements of one sample. The characteristics established in our study are in concordance with the manufacturer's specifications established for a ladder as a sample. However, the concentration determination may vary depending on chip preparation, sample storage and concentration. The 15% variation of concentration determination repeatability was shown to be partly proportional and can be suppressed by proper normalization.

  20. Direct detection of methicillin-resistant Staphylococcus aureus from blood cultures using an immunochromatographic immunoassay-based MRSA rapid kit for the detection of penicillin-binding protein 2a.

    Science.gov (United States)

    Shin, Kyeong Seob; Song, Hyung Geun; Kim, Haejung; Yoon, Sangsun; Hong, Seung Bok; Koo, Sun Hoe; Kim, Jimyung; Kim, Jongwan; Roh, Kyoung Ho

    2010-07-01

    Using an EZ-Step MRSA rapid kit, a novel screening test for methicillin-resistant Staphylococcus aureus (MRSA) that detects penicillin-binding protein 2a, 34 of 36 MRSA-positive clinical blood culture samples were positive on direct testing (sensitivity, 94.4%), whereas 21 of 21 methicillin-susceptible S. aureus-positive samples were negative (specificity, 100%).

  1. Knowledge and attitude of women regarding breast cancer screening tests in Eastern Iran.

    Science.gov (United States)

    Izanloo, Azra; Ghaffarzadehgan, Kamran; Khoshroo, Fahimeh; Erfani Haghiri, Maryam; Izanloo, Sara; Samiee, Mohadeseh; Tabatabaei, Alireza; Mirshahi, Azadeh; Fakoor, Morteza; Moghadam, Najmeh Jafari; Sadrzadeh, Sayyed Majid

    2018-01-01

    According to recent statistics, there has been a rapid growth of breast cancer in developing countries. Thus, early detection is essential. This study is based on the perception of people in the Northeast of Iran regarding breast cancer screening. In a cross-sectional study, 1469 women were selected randomly in the period from April to November 2016. The study population consisted of women or their companions referring to outpatient clinics or people in public urban areas who filled out a breast cancer screening questionnaire in an interview. The patients' age was in the range of 14 to 84 years (mean = 38.8). More than 84% of interviewees were not informed of breast cancer and screening tests. The main reasons mentioned by patients for their failure to do screening tests was 'absence of any symptom or problem' and 'they did not think it was necessary'.There was not a significant difference between income level, marital status and knowledge of people about breast cancer screening tests (P > 0.05). However, employment, education level and family history had a positive effect on people's awareness of breast cancer and its screening tests (P economic classes was the main barrier to breast cancer screening. In this regard, organizing training programs by physicians and the media can help raise screening rates.

  2. The impact of screening-test negative samples not enumerated by MPN

    DEFF Research Database (Denmark)

    Corbellini, Luis Gustavo; Ribeiro Duarte, Ana Sofia; de Knegt, Leonardo

    2015-01-01

    that includes false negative results from the screening, and a third that considers the entire data set. The relative sensitivity of the screening test was also calculated assuming as gold standard samples with confirmed Salmonella. Salmonella was confirmed by a reference laboratory in 29 samples either...

  3. Cost-effectiveness of one versus two sample faecal immunochemical testing for colorectal cancer screening.

    Science.gov (United States)

    Goede, S Lucas; van Roon, Aafke H C; Reijerink, Jacqueline C I Y; van Vuuren, Anneke J; Lansdorp-Vogelaar, Iris; Habbema, J Dik F; Kuipers, Ernst J; van Leerdam, Monique E; van Ballegooijen, Marjolein

    2013-05-01

    The sensitivity and specificity of a single faecal immunochemical test (FIT) are limited. The performance of FIT screening can be improved by increasing the screening frequency or by providing more than one sample in each screening round. This study aimed to evaluate if two-sample FIT screening is cost-effective compared with one-sample FIT. The MISCAN-colon microsimulation model was used to estimate costs and benefits of strategies with either one or two-sample FIT screening. The FIT cut-off level varied between 50 and 200 ng haemoglobin/ml, and the screening schedule was varied with respect to age range and interval. In addition, different definitions for positivity of the two-sample FIT were considered: at least one positive sample, two positive samples, or the mean of both samples being positive. Within an exemplary screening strategy, biennial FIT from the age of 55-75 years, one-sample FIT provided 76.0-97.0 life-years gained (LYG) per 1000 individuals, at a cost of € 259,000-264,000 (range reflects different FIT cut-off levels). Two-sample FIT screening with at least one sample being positive provided 7.3-12.4 additional LYG compared with one-sample FIT at an extra cost of € 50,000-59,000. However, when all screening intervals and age ranges were considered, intensifying screening with one-sample FIT provided equal or more LYG at lower costs compared with two-sample FIT. If attendance to screening does not differ between strategies it is recommended to increase the number of screening rounds with one-sample FIT screening, before considering increasing the number of FIT samples provided per screening round.

  4. The Clinical and Economic Benefits of Co-Testing Versus Primary HPV Testing for Cervical Cancer Screening: A Modeling Analysis.

    Science.gov (United States)

    Felix, Juan C; Lacey, Michael J; Miller, Jeffrey D; Lenhart, Gregory M; Spitzer, Mark; Kulkarni, Rucha

    2016-06-01

    Consensus United States cervical cancer screening guidelines recommend use of combination Pap plus human papillomavirus (HPV) testing for women aged 30 to 65 years. An HPV test was approved by the Food and Drug Administration in 2014 for primary cervical cancer screening in women age 25 years and older. Here, we present the results of clinical-economic comparisons of Pap plus HPV mRNA testing including genotyping for HPV 16/18 (co-testing) versus DNA-based primary HPV testing with HPV 16/18 genotyping and reflex cytology (HPV primary) for cervical cancer screening. A health state transition (Markov) model with 1-year cycling was developed using epidemiologic, clinical, and economic data from healthcare databases and published literature. A hypothetical cohort of one million women receiving triennial cervical cancer screening was simulated from ages 30 to 70 years. Screening strategies compared HPV primary to co-testing. Outcomes included total and incremental differences in costs, invasive cervical cancer (ICC) cases, ICC deaths, number of colposcopies, and quality-adjusted life years for cost-effectiveness calculations. Comprehensive sensitivity analyses were performed. In a simulation cohort of one million 30-year-old women modeled up to age 70 years, the model predicted that screening with HPV primary testing instead of co-testing could lead to as many as 2,141 more ICC cases and 2,041 more ICC deaths. In the simulation, co-testing demonstrated a greater number of lifetime quality-adjusted life years (22,334) and yielded $39.0 million in savings compared with HPV primary, thereby conferring greater effectiveness at lower cost. Model results demonstrate that co-testing has the potential to provide improved clinical and economic outcomes when compared with HPV primary. While actual cost and outcome data are evaluated, these findings are relevant to U.S. healthcare payers and women's health policy advocates seeking cost-effective cervical cancer screening

  5. Fluorescent screens and image processing for the APS linac test stand

    International Nuclear Information System (INIS)

    Berg, W.; Ko, K.

    1992-01-01

    A fluorescent screen was used to monitor relative beam position and spot size of a 56-MeV electron beam in the linac test stand. A chromium doped alumina ceramic screen inserted into the beam was monitored by a video camera. The resulting image was captured using a frame grabber and stored into memory. Reconstruction and analysis of the stored image was performed using PV-WAVE. This paper will discuss the hardware and software implementation of the fluorescent screen and imaging system. Proposed improvements for the APS linac fluorescent screens and image

  6. A virtual test of screening technology based on the AGEIA PhysX

    Energy Technology Data Exchange (ETDEWEB)

    Ai-min Li; Rui-ling Lv; Chu-sheng Liu [China University of Mining and Technology, Xuzhou (China). School of Mechanical and Electrical Engineering

    2008-06-15

    The authors have created a virtual test of vibration particle-screening using Autodesk's 3ds Max software, the MAXScript scripting language and the AGEIA PhysX physics processing unit (PPU). The affect of various parameters on screening efficiency were modeled. The parameters included vibration amplitude, frequency and direction. The length and inclination of the vibrating surface were also varied. The virtual experiment is in basic agreement with results predicted from screening theory. This shows that the virtual screener can be used for preliminary investigations and the results used to evaluate screen design. In addition it can help with theoretical research. 11 refs., 7 figs., 7 tabs.

  7. On the Estimation of Disease Prevalence by Latent Class Models for Screening Studies Using Two Screening Tests with Categorical Disease Status Verified in Test Positives Only

    Science.gov (United States)

    Chu, Haitao; Zhou, Yijie; Cole, Stephen R.; Ibrahim, Joseph G.

    2010-01-01

    Summary To evaluate the probabilities of a disease state, ideally all subjects in a study should be diagnosed by a definitive diagnostic or gold standard test. However, since definitive diagnostic tests are often invasive and expensive, it is generally unethical to apply them to subjects whose screening tests are negative. In this article, we consider latent class models for screening studies with two imperfect binary diagnostic tests and a definitive categorical disease status measured only for those with at least one positive screening test. Specifically, we discuss a conditional independent and three homogeneous conditional dependent latent class models and assess the impact of misspecification of the dependence structure on the estimation of disease category probabilities using frequentist and Bayesian approaches. Interestingly, the three homogeneous dependent models can provide identical goodness-of-fit but substantively different estimates for a given study. However, the parametric form of the assumed dependence structure itself is not “testable” from the data, and thus the dependence structure modeling considered here can only be viewed as a sensitivity analysis concerning a more complicated non-identifiable model potentially involving heterogeneous dependence structure. Furthermore, we discuss Bayesian model averaging together with its limitations as an alternative way to partially address this particularly challenging problem. The methods are applied to two cancer screening studies, and simulations are conducted to evaluate the performance of these methods. In summary, further research is needed to reduce the impact of model misspecification on the estimation of disease prevalence in such settings. PMID:20191614

  8. Immunochemical faecal occult blood test for colorectal cancer screening: a systematic review.

    Science.gov (United States)

    Syful Azlie, M F; Hassan, M R; Junainah, S; Rugayah, B

    2015-02-01

    A systematic review on the effectiveness and costeffectiveness of Immunochemical faecal occult IFOBT for CRC screening was carried out. A total of 450 relevant titles were identified, 41 abstracts were screened and 18 articles were included in the results. There was fair level of retrievable evidence to suggest that the sensitivity and specificity of IFOBT varies with the cut-off point of haemoglobin, whereas the diagnostic accuracy performance was influenced by high temperature and haemoglobin stability. A screening programme using IFOBT can be effective for prevention of advanced CRC and reduced mortality. There was also evidence to suggest that IFOBT is cost-effective in comparison with no screening, whereby a two-day faecal collection method was found to be costeffective as a means of screening for CRC. Based on the review, quantitative IFOBT method can be used in Malaysia as a screening test for CRC. The use of fully automated IFOBT assay would be highly desirable.

  9. Clinical experience from Thailand noninvasive prenatal testing as screening tests for trisomies 21, 18 and 13 in 4736 pregnancies

    DEFF Research Database (Denmark)

    Manotaya, S.; Xu, H.; Uerpairojkit, B.

    2016-01-01

    -risk pregnancies, either with advanced maternal age or positive serum biochemical tests, and 1889 low-risk pregnancies without conventional indications; 99.9% (4732/4736) of the participants with a median maternal age of 35years old received reports, and 1.3% (63/4732) were classified as test positive, including...... testing (NIPT) has enabled efficient and accurate screening for T21, T18 and T13. Various professional societies suggested that NIPT could be considered as a second-tier screening test for women at high risk for aneuploidy. What does this study add? This study reports the performance of NIPT...

  10. Knowledge of prenatal screening and psychological management of test decisions

    DEFF Research Database (Denmark)

    Dahl, Katja; Hvidman, Lone; Jørgensen, Finn Stener

    2010-01-01

    well-being respectively worries in pregnancy. METHODS: A population-based cross-sectional study with 6,427 pregnant women consecutively included before the time of a nuchal translucency scan. Participants were recruited from three Danish obstetric departments offering prenatal screening free of charge....... The results presented are based on 4,111 pregnant women (64%). Knowledge was measured by 15 knowledge questions. The primary outcomes were measured by use of pre-existing validated scales i.e. The Decisional Conflict Scale, the WHO well-being index, and the Cambridge Worry Scale. Associations were analysed...... associated with higher levels of well-being (adjusted linear coefficient 0.51 (0.26 to 0.75), p

  11. STRATEGIES TO REDUCE OR REPLACE THE USE OF ANIMALS IN THE ENDOCRINE SCREENING AND TESTING PROGRAM.

    Science.gov (United States)

    Abstract: The US Environmental Protection Agency (EPA) is developing a screening and testing program for endocrine disrupting chemicals (EDCs) to detect alterations of hypothalamic-pituitary-gonadal (HPG) function, estrogen, androgen and thyroid hormone synthesis and androgen (AR...

  12. Evaluating the evidence: direct-to-consumer screening tests advertised online.

    Science.gov (United States)

    Lovett, Kimberly M; Mackey, Timothy K; Liang, Bryan A

    2012-09-01

    Unsupervised online direct-to-consumer (DTC) access to medical services has rapidly expanded to medical screening tests, which have not been critically evaluated for their evidence basis. The objective of this study is to identify the scope of online-advertised DTC screening tests, outline the evidence for use of available DTC testing and suggest regulatory reform to address the relevant issues. An observational study of website advertisements, testing services and counselling/follow-up services for DTC testing was conducted. Data were collected from websites between 4 April and 1 June 2011. Each website was assessed for tests offered, advertised indications and availability of counselling/follow-up services. Advertised testing indications were compared with US Preventive Services Task Force recommendations and/or specialty guidelines and categorized as Supported, Against, Insufficient Evidence or No Guidance. Of 20 companies identified as offering DTC screening tests, 95% (19/20) do not clearly offer pretest counselling, post-test counselling and/or test follow-up. One hundred and twenty-seven different tests were identified. Only 19/127 (15%) could be Supported for screening in a target group selected for testing; 38/127 (30%) were given recommendations to avoid use in specific target group(s) selected for testing ('Against recommendations'); 29/127 (23%) had Insufficient Evidence of value, and for 64/127 (50%) No Guidance could be given. Only 4/127 (3%) tests were Supported for general screening use. Virtually all identified medical tests advertised and offered DTC are not recommended for use in screening by evidence-based guidelines. Limited oversight may lead to inaccurate self-diagnosis, treatment and wasted health resources.

  13. Detection of lung cancer through low-dose CT screening (NELSON): a prespecified analysis of screening test performance and interval cancers.

    Science.gov (United States)

    Horeweg, Nanda; Scholten, Ernst Th; de Jong, Pim A; van der Aalst, Carlijn M; Weenink, Carla; Lammers, Jan-Willem J; Nackaerts, Kristiaan; Vliegenthart, Rozemarijn; ten Haaf, Kevin; Yousaf-Khan, Uraujh A; Heuvelmans, Marjolein A; Thunnissen, Erik; Oudkerk, Matthijs; Mali, Willem; de Koning, Harry J

    2014-11-01

    Low-dose CT screening is recommended for individuals at high risk of developing lung cancer. However, CT screening does not detect all lung cancers: some might be missed at screening, and others can develop in the interval between screens. The NELSON trial is a randomised trial to assess the effect of screening with increasing screening intervals on lung cancer mortality. In this prespecified analysis, we aimed to assess screening test performance, and the epidemiological, radiological, and clinical characteristics of interval cancers in NELSON trial participants assigned to the screening group. Eligible participants in the NELSON trial were those aged 50-75 years, who had smoked 15 or more cigarettes per day for more than 25 years or ten or more cigarettes for more than 30 years, and were still smoking or had quit less than 10 years ago. We included all participants assigned to the screening group who had attended at least one round of screening. Screening test results were based on volumetry using a two-step approach. Initially, screening test results were classified as negative, indeterminate, or positive based on nodule presence and volume. Subsequently, participants with an initial indeterminate result underwent follow-up screening to classify their final screening test result as negative or positive, based on nodule volume doubling time. We obtained information about all lung cancer diagnoses made during the first three rounds of screening, plus an additional 2 years of follow-up from the national cancer registry. We determined epidemiological, radiological, participant, and tumour characteristics by reassessing medical files, screening CTs, and clinical CTs. The NELSON trial is registered at www.trialregister.nl, number ISRCTN63545820. 15,822 participants were enrolled in the NELSON trial, of whom 7915 were assigned to low-dose CT screening with increasing interval between screens, and 7907 to no screening. We included 7155 participants in our study, with

  14. Screening for mikroalbuminuri med Micral-Test. En semikvantitativ urinstix

    DEFF Research Database (Denmark)

    Jensen, J S; Borch-Johnsen, K; Feldt-Rasmussen, B F

    1993-01-01

    , specificity and diagnostic specificity in detecting microalbuminuria was 92, 58 and 12% respectively. The prevalence of microalbuminuria was 5.6%. In conclusion, the Micral-Test is highly sensitive in detecting microalbuminuria, but at the expense of a relatively high number of false positive tests....

  15. Astrophysical tests of gravity: a screening map of the nearby universe

    Energy Technology Data Exchange (ETDEWEB)

    Cabré, Anna; Vikram, Vinu; Jain, Bhuvnesh [Center for Particle Cosmology, Department of Physics and Astronomy, University of Pennsylvania, 209 South 33rd Street, Philadelphia, PA 19104-6396 (United States); Zhao, Gong-Bo; Koyama, Kazuya, E-mail: annanusca@gmail.com, E-mail: vinu@sas.upenn.edu, E-mail: gong-bo.zhao@port.ac.uk, E-mail: bjain@physics.upenn.edu, E-mail: Kazuya.Koyama@port.ac.uk [Institute of Cosmology and Gravitation, University of Portsmouth, Dennis Sciama Building, Burnaby Road, Portsmouth, PO1 3FX (United Kingdom)

    2012-07-01

    Astrophysical tests of modified gravity theories in the nearby universe have been emphasized recently by Hui 2009 and Jain 2011. A key element of such tests is the screening mechanism whereby general relativity is restored in massive halos or high density environments like the Milky Way. In chameleon theories of gravity, including all f(R) models, field dwarf galaxies may be unscreened and therefore feel an extra force, as opposed to screened galaxies. The first step to study differences between screened and unscreened galaxies is to create a 3D screening map. We use N-body simulations to test and calibrate simple approximations to determine the level of screening in galaxy catalogs. Sources of systematic errors in the screening map due to observational inaccuracies are modeled and their contamination is estimated. We then apply our methods to create a map out to 200 Mpc in the Sloan Digital Sky Survey footprint using data from the Sloan survey and other sources. In two companion papers this map will be used to carry out new tests of gravity using distance indicators and the disks of dwarf galaxies. We also make our screening map publicly available.

  16. Comparative studies of commercially available T4-RIA-kits. Pt. 2

    International Nuclear Information System (INIS)

    Schmidt, H.A.E.; Lipke, P.

    1978-01-01

    The investigation of the tested commercially available T 4 -RIA-Kits have shown that: The separation of hypo-, eu- and hyperthyroid values is better with kits a) and f) than with b), c), d) and e), though all kits give acceptable values under routine operating conditions, kit b) takes less time and work than the other tested kits, depending on the kit used, the time needed for 100 determinations varies between 1,5 and 4 hr. A general recommendation for one of the tested T 4 -RIA-Kits cannot be made since the choice of a kit depends not only on the criteria discussed but also on local circumstances. (orig.) [de

  17. [Consistency study of PowerPlex 21 kit and Goldeneye 20A kit and forensic application].

    Science.gov (United States)

    Ren, He; Liu, Ying; Zhang, Qing-Xia; Jiao, Zhang-Ping

    2014-06-01

    To ensure the consistency of genotype results for PowerPlex 21 kit and Goldeneye 20A kit. The STR loci were amplified in DNA samples from 205 unrelated individuals in Beijing Han population. And consistency of 19 overlap STR loci typing were observed. The genetic polymorphism of D1S1656 locus was obtained. All 19 overlap loci typing showed consistent. The proportion of peak height of heterozygous loci in two kits showed no statistical difference (P > 0.05). The observed heterozygosis of D1S1656 was 0.878. The discrimination power was 0.949. The excluding probability of paternity of triplet was 0.751. The excluding probability of paternity of diploid was 0.506. The polymorphism information content was 0.810. PowerPlex 21 kit and Goldeneye 20A kit present a good consistency. The primer design is reasonable. The polymorphism of D1S1656 is good. The two kits can be used for human genetic analysis, paternity test, and individual identification in forensic practice.

  18. Perceived effectiveness of HPV test as a primary screening modality among US providers.

    Science.gov (United States)

    Cooper, Crystale Purvis; Saraiya, Mona

    2015-09-01

    The human papillomavirus (HPV) test, administered alone without the Papanicolaou (Pap) test, was recently recognized as a cervical cancer screening option in the United States by the Society of Gynecologic Oncology and the American Society for Colposcopy and Cervical Pathology, and the Food and Drug Administration has approved an HPV test for primary screening. Surveys of US internists, family practitioners, nurse practitioners, and obstetrician-gynecologists were conducted in 2009 and 2012 to investigate providers' perceptions of the effectiveness of the HPV test administered alone as a population-based screening modality (2009: N=1040, 141-494 per provider group; 2012: N=1039, 155-435 per provider group). The majority in each provider group agreed that the HPV test administered alone is an effective screening modality in 2009 (75.3%-86.1%) and 2012 (79.5%-91.8%), and agreement rose significantly during this time period among family practitioners (χ(2)=15.26, df=1, ptest administered alone is an effective cervical cancer screening modality was widespread among providers in both 2009 and 2012, however implementation of guidelines for screening with the HPV test may be influenced by many other factors including reimbursement and patient preferences. Published by Elsevier Inc.

  19. 77 FR 15101 - Results From Inert Ingredient Test Orders Issued Under EPA's Endocrine Disruptor Screening...

    Science.gov (United States)

    2012-03-14

    ... the selection criteria for endocrine testing under the Safe Drinking Water Act (SDWA). EPA has no...) because the chemicals meet the selection criteria. EPA has no plans to issue further test orders for the... Screening Program (EDSP) and the Federal Food, Drug, and Cosmetic Act (FFDCA). In response to the test...

  20. Comparison of accuracy measures of two screening tests for gestational diabetes mellitus

    NARCIS (Netherlands)

    van Leeuwen, Marsha; Zweers, Egbert J. K.; Opmeer, Brent C.; van Ballegooie, Evert; ter Brugge, Henk G.; de Valk, Harold W.; Mol, Ben W. J.; Visser, Gerard H. A.

    2007-01-01

    OBJECTIVE: To compare the accuracy measures of the random glucose test and the 50-g glucose challenge test as screening tests for gestational diabetes mellitus (GDM). RESEARCH DESIGN AND METHODS: In this prospective cohort study, pregnant women without preexisting diabetes in two perinatal centers

  1. Results from the Dutch speech-in-noise screening test by telephone

    NARCIS (Netherlands)

    Smits, C.H.M.; Houtgast, T.

    2005-01-01

    OBJECTIVE: The objective of the study was to implement a previously developed automatic speech-in-noise screening test by telephone (Smits, Kapteyn, & Houtgast, 2004), introduce it nationwide as a self-test, and analyze the results. DESIGN: The test was implemented on an interactive voice response

  2. Mobile Probing Kit

    DEFF Research Database (Denmark)

    Larsen, Jakob Eg; Sørensen, Lene Tolstrup; Sørensen, J.K.

    2007-01-01

    Mobile Probing Kit is a low tech and low cost methodology for obtaining inspiration and insights into user needs, requirements and ideas in the early phases of a system's development process. The methodology is developed to identify user needs, requirements and ideas among knowledge workers...... characterized as being highly nomadic and thus potential users of mobile and ubiquitous technologies. The methodology has been applied in the 1ST MAGNET Beyond project in order to obtain user needs and requirements in the process of developing pilot services. We report on the initial findings from applying...

  3. Discrimination indices as screening tests for beta-thalassemic trait.

    Science.gov (United States)

    Ntaios, George; Chatzinikolaou, Anastasia; Saouli, Zoi; Girtovitis, Fotios; Tsapanidou, Maria; Kaiafa, Georgia; Kontoninas, Zisis; Nikolaidou, Androula; Savopoulos, Christos; Pidonia, Ifigenia; Alexiou-Daniel, Stiliani

    2007-07-01

    The two most frequent microcytic anemias are beta-thalassemic trait (beta-TT) and iron deficiency anemia (IDA). Several discrimination indices have been proposed to distinguish between these two conditions. These indices are derived from several simple red blood cell indices, like red blood cell (RBC) count, mean cell volume, and RBC distribution width (RDW), as these are provided by electronic cell counters. The purpose of the study is to examine the diagnostic accuracy of six discrimination indices in the differentiation between IDA and beta-TT. The six discrimination indices that were examined were as follows: Mentzer Index (MI), Green & King Index (G&K), RDW Index (RDWI), England & Fraser Index (E&F), RDW, and RBC count. We calculated these indices on 373 patients (205 men, 168 women) with beta-TT and 120 patients (50 men, 70 women) with IDA, as well as their sensitivity, specificity, positive and negative prognostic value, efficiency, and Youden's index (YI). G&K shows the highest reliability, followed by E&F, RBC count, MI, and RDWI. On the contrary, RDW completely failed to differentiate between IDA and beta-TT. G&K proved to be the most reliable index as it had the highest sensitivity (75.06%), efficiency (80.12%), and YI (70.86%) for the detection of beta-TT. These six discrimination indices cannot be relied on for a safe differential diagnosis between beta-TT and IDA. They do have high specificity, but their sensitivity for the detection of beta-TT is not satisfactory. Consequently, they cannot be used neither as a screening tool for beta-TT because they could result in a significant number of false negative results.

  4. Results of a Community-Based Randomized Trial to Increase Colorectal Cancer Screening Among Filipino Americans

    Science.gov (United States)

    Bastani, Roshan; Danao, Leda L.; Antonio, Cynthia; Garcia, Gabriel M.; Crespi, Catherine M.

    2010-01-01

    Objectives. We conducted 1 of the first community-based trials to develop a multicomponent intervention that would increase colorectal cancer screening among an Asian American population. Methods. Filipino Americans (n = 548) nonadherent to colorectal cancer (CRC) screening guidelines were randomized into an intervention group that received an education session on CRC screening and free fecal occult blood test (FOBT) kits; a second intervention group that received an education session but no free FOBT kits; and a control group that received an education session on the health benefits of physical activity. Results. Self-reported CRC screening rates during the 6-month follow-up period were 30%, 25%, and 9% for participants assigned to intervention with FOBT kit, intervention without the kit, and control group, respectively. Participants in either of the 2 intervention groups were significantly more likely to report screening at follow-up than were participants in the control group. Conclusions. A multicomponent intervention that includes an educational group session in a community setting can significantly increase CRC screening among Filipino Americans, even when no free FOBT kits are distributed. PMID:20864724

  5. Education Payload Operation - Kit D

    Science.gov (United States)

    Keil, Matthew

    2009-01-01

    Education Payload Operation - Kit D (EPO-Kit D) includes education items that will be used to support the live International Space Station (ISS) education downlinks and Education Payload Operation (EPO) demonstrations onboard the ISS. The main objective of EPO-Kit D supports the National Aeronautics and Space Administration (NASA) goal of attracting students to study and seek careers in science, technology, engineering, and mathematics.

  6. Implementation and process evaluation of a workplace colorectal cancer screening program in eastern Washington.

    Science.gov (United States)

    Hannon, Peggy A; Vu, Thuy; Ogdon, Sara; Fleury, Emily M; Yette, Emily; Wittenberg, Reva; Celedonia, Megan; Bowen, Deborah J

    2013-03-01

    Colorectal cancer screening is a life-saving intervention, but screening rates are low. The authors implemented and evaluated the Spokane Colorectal Cancer Screening Program-a novel worksite intervention to promote colorectal cancer screening that used a combination of evidence-based strategies recommended by the Guide to Community Preventive Services, as well as additional strategies. Over a period of approximately 3 months, participating worksites held one or more physician-led seminars about colorectal cancer screening for employees. They also distributed free fecal immunochemical tests at the worksite to employees 50 years and older, and they provided test results to employees and their primary care physician. The authors measured attendance at seminars, test kits taken and returned, employee awareness of the program, and colorectal cancer screening rates in participating and comparison worksites. It is estimated that 9% of eligible employees received kits at the worksite, and 4% were screened with these kits. The Spokane Colorectal Cancer Screening Program was a promising pilot test of an innovative worksite screening program that successfully translated evidence-based strategies into practical use in a brief period of time, and it merits a larger study to be able to test its effects more rigorously.

  7. Evaluating the Zebrafish Embryo Toxicity Test for Pesticide Hazard Screening

    Science.gov (United States)

    Given the numerous chemicals used in society, it is critical to develop tools for accurate and efficient evaluation of potential risks to human and ecological receptors. Fish embryo acute toxicity tests are 1 tool that has been shown to be highly predictive of standard, more reso...

  8. Quantiferon test for tuberculosis screening in sarcoidosis patients

    DEFF Research Database (Denmark)

    Milman, Nils; Søborg, Bolette; Svendsen, Claus Bo

    2011-01-01

    Tumour necrosis factor-alpha (TNF-α) inhibitors have been introduced in the treatment of refractory sarcoidosis. These biologics may reactivate latent tuberculosis infection (LTBI). Despite its known limitations, the tuberculin skin test (TST) is currently used for the diagnosis of LTBI in Danish...

  9. Evaluation of microscopy and rapid diagnostic tests in screening ...

    African Journals Online (AJOL)

    Malaria is a life-threatening disease caused by the protozoa of the genus Plasmodium. Infection of individual is through the bites of infected female Anopheles mosquitoes. This study evaluated the performance of microscopy and rapid diagnostic tests (RDTs) in diagnosing malaria. A total of 400 clinically suspected malaria ...

  10. Impact on colorectal cancer mortality of screening programmes based on the faecal immunochemical test.

    Science.gov (United States)

    Zorzi, Manuel; Fedeli, Ugo; Schievano, Elena; Bovo, Emanuela; Guzzinati, Stefano; Baracco, Susanna; Fedato, Chiara; Saugo, Mario; Dei Tos, Angelo Paolo

    2015-05-01

    Colorectal cancer (CRC) screening programmes based on the guaiac faecal occult blood test (gFOBT) reduce CRC-specific mortality. Several studies have shown higher sensitivity with the faecal immunochemical test (FIT) compared with gFOBT. We carried out an ecological study to evaluate the impact of FIT-based screening programmes on CRC mortality. In the Veneto Region (Italy), biennial FIT-based screening programmes that invited 50-69-year-old residents were introduced in different areas between 2002 and 2009. We compared CRC mortality rates from 1995 to 2011 between the areas where screening started in 2002-2004 (early screening areas (ESA)) and areas that introduced the screening in 2008-2009 (late screening areas (LSA)) using Poisson regression models. We also compared available data on CRC incidence rates (1995-2007) and surgical resection rates (2001-2012). Before the introduction of screening, CRC mortality and incidence rates in the two areas were similar. Compared with 1995-2000, 2006-2011 mortality rates were 22% lower in the ESA than in the LSA (rate ratio (RR)=0.78; 95% CI 0.68 to 0.89). The reduction was larger in women (RR=0.64; CI 0.51 to 0.80) than in men (RR=0.87; CI 0.73 to 1.04). In the ESA, incidence and surgery rates peaked during the introduction of the screening programme and then returned to the baseline (2006-2007 incidence) or dropped below initial values (surgery after 2007). FIT-based screening programmes were associated with a significant reduction in CRC mortality. This effect took place much earlier than reported by gFOBT-based trials and observational studies. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.

  11. Microgripper construction kit

    Science.gov (United States)

    Gengenbach, Ulrich K.; Hofmann, Andreas; Engelhardt, Friedhelm; Scharnowell, Rudolf; Koehler, Bernd

    2001-10-01

    A large number of microgrippers has been developed in industry and academia. Although the importance of hybrid integration techniques and hence the demand for assembly tools grows continuously a large part of these developments has not yet been used in industrial production. The first grippers developed for microassembly were basically vacuum grippers and downscaled tweezers. Due to increasingly complex assembly tasks more and more functionality such as sensing or additional functions such as adhesive dispensing has been integrated into gripper systems over the last years. Most of these gripper systems are incompatible since there exists no standard interface to the assembly machine and no standard for the internal modules and interfaces. Thus these tools are not easily interchangeable between assembly machines and not easily adaptable to assembly tasks. In order to alleviate this situation a construction kit for modular microgrippers is being developed. It is composed of modules with well defined interfaces that can be combined to build task specific grippers. An abstract model of a microgripper is proposed as a tool to structure the development of the construction kit. The modular concept is illustrated with prototypes.

  12. Evaluation of the concomitant use of two different EIA tests for HIV screening in blood banks

    Directory of Open Access Journals (Sweden)

    Otani Marcia M.

    2003-01-01

    Full Text Available OBJECTIVE: In 1998, the Brazilian Ministry of Health made it mandatory for all blood banks in the country to screen donated blood for human immunodeficiency virus (HIV concomitantly using two different enzyme immunoassay (EIA tests. Concerned with the best use of available resources, our objective with this study was to evaluate the usefulness of conducting two EIA screening tests instead of just one. METHODS: We analyzed data from 1999 through 2001 obtained by testing 698 191 units of donated blood using two EIA HIV screening tests concomitantly at the Pro-Blood Foundation/Blood Center of São Paulo (Fundação Pró-Sangue/Hemocentro de São Paulo, which is a major blood center in the city of São Paulo, Brazil. All samples reactive in at least one of the two EIA tests were submitted for confirmation by a Western blot (WB test, and the persons who had donated those samples were also asked to return and provide a follow-up sample. RESULTS: Out of the 698 191 blood units that were donated, 2 718 of them (0.4% had to be discarded because they were reactive to at least one of the EIA tests. There were two WB-positive donation samples that were reactive in only one HIV EIA screening test. On their follow-up samples, both donors tested WB-negative. These cases were considered false positive results at screening. Of the 2 718 donors who were asked to return and provide a follow-up sample, 1 576 of them (58% did so. From these 1 576 persons, we found that there were two individuals who had been reactive to only one of the two EIA screening tests and who had also been negative on the WB at screening but who were fully seroconverted on the follow-up sample. We thus estimated that, in comparison to the use of a single EIA screening test, the use of two EIA screening tests would detect only one extra sample out of 410 700 units of blood. CONCLUSIONS: Our data do not support the use of two different, concomitant EIA screening tests for HIV. The great

  13. Optimisation and assessment of three modern touch screen tablet computers for clinical vision testing.

    Directory of Open Access Journals (Sweden)

    Humza J Tahir

    Full Text Available Technological advances have led to the development of powerful yet portable tablet computers whose touch-screen resolutions now permit the presentation of targets small enough to test the limits of normal visual acuity. Such devices have become ubiquitous in daily life and are moving into the clinical space. However, in order to produce clinically valid tests, it is important to identify the limits imposed by the screen characteristics, such as resolution, brightness uniformity, contrast linearity and the effect of viewing angle. Previously we have conducted such tests on the iPad 3. Here we extend our investigations to 2 other devices and outline a protocol for calibrating such screens, using standardised methods to measure the gamma function, warm up time, screen uniformity and the effects of viewing angle and screen reflections. We demonstrate that all three devices manifest typical gamma functions for voltage and luminance with warm up times of approximately 15 minutes. However, there were differences in homogeneity and reflectance among the displays. We suggest practical means to optimise quality of display for vision testing including screen calibration.

  14. Optimisation and assessment of three modern touch screen tablet computers for clinical vision testing.

    Science.gov (United States)

    Tahir, Humza J; Murray, Ian J; Parry, Neil R A; Aslam, Tariq M

    2014-01-01

    Technological advances have led to the development of powerful yet portable tablet computers whose touch-screen resolutions now permit the presentation of targets small enough to test the limits of normal visual acuity. Such devices have become ubiquitous in daily life and are moving into the clinical space. However, in order to produce clinically valid tests, it is important to identify the limits imposed by the screen characteristics, such as resolution, brightness uniformity, contrast linearity and the effect of viewing angle. Previously we have conducted such tests on the iPad 3. Here we extend our investigations to 2 other devices and outline a protocol for calibrating such screens, using standardised methods to measure the gamma function, warm up time, screen uniformity and the effects of viewing angle and screen reflections. We demonstrate that all three devices manifest typical gamma functions for voltage and luminance with warm up times of approximately 15 minutes. However, there were differences in homogeneity and reflectance among the displays. We suggest practical means to optimise quality of display for vision testing including screen calibration.

  15. Personal radiotoxicological (first aid) kit

    International Nuclear Information System (INIS)

    Gachalyi, Andras; Gyulai, Gabor

    2014-01-01

    In recent years, with the spread of nuclear industrial activities, and the widespread use of radioactive materials and products the possibility of radionuclide contamination of humans and animals has significantly increased. During nuclear tests or reactor accidents, a large amount of radioactive materials may enter the environment which can contaminate the living environment (air, water, vegetation, soil), for a long period. This contamination may enter living organisms by inhalation, intake and ingestion, causing severe biological damage. As an example the Chernobyl reactor accident can be mentioned, where there was no possibility for the decorporation of isotopes, as there were no products available such as the 'RADISTOP'. To achieve appropriate decorporating (and decontaminating) treatment which is effective, it is highly recommendable to use a personal Radiotoxicological First Aid Kit (PRK) within the shortest possible time after internal contamination. This unit provides effective treatment to decorporate the most common incorporated fission products. (author)

  16. Incidence of interval cancers in faecal immunochemical test colorectal screening programmes in Italy.

    Science.gov (United States)

    Giorgi Rossi, Paolo; Carretta, Elisa; Mangone, Lucia; Baracco, Susanna; Serraino, Diego; Zorzi, Manuel

    2018-03-01

    Objective In Italy, colorectal screening programmes using the faecal immunochemical test from ages 50 to 69 every two years have been in place since 2005. We aimed to measure the incidence of interval cancers in the two years after a negative faecal immunochemical test, and compare this with the pre-screening incidence of colorectal cancer. Methods Using data on colorectal cancers diagnosed in Italy from 2000 to 2008 collected by cancer registries in areas with active screening programmes, we identified cases that occurred within 24 months of negative screening tests. We used the number of tests with a negative result as a denominator, grouped by age and sex. Proportional incidence was calculated for the first and second year after screening. Results Among 579,176 and 226,738 persons with negative test results followed up at 12 and 24 months, respectively, we identified 100 interval cancers in the first year and 70 in the second year. The proportional incidence was 13% (95% confidence interval 10-15) and 23% (95% confidence interval 18-25), respectively. The estimate for the two-year incidence is 18%, which was slightly higher in females (22%; 95% confidence interval 17-26), and for proximal colon (22%; 95% confidence interval 16-28). Conclusion The incidence of interval cancers in the two years after a negative faecal immunochemical test in routine population-based colorectal cancer screening was less than one-fifth of the expected incidence. This is direct evidence that the faecal immunochemical test-based screening programme protocol has high sensitivity for cancers that will become symptomatic.

  17. TORCH Screening Test in Pregnant Women of Kirkuk City

    Directory of Open Access Journals (Sweden)

    Hiro M. Obaid

    2017-07-01

    Cytomegalovirus, Rubella and Toxoplasma are prevalent among pregnant women in Kirkuk city and probably they are the causative agents of abortion and infertility found among them, therefore it's better for pregnant woman or those planning to become pregnant to be tested for TORCH infections, and vaccinated against Rubella, Cytomegalovirus, Herpes simplex virus and Toxoplasma to grantee her health  as well as her baby.

  18. The clinical utility of HPV DNA testing in cervical cancer screening strategies.

    Science.gov (United States)

    Bhatla, Neerja; Moda, Nidhi

    2009-09-01

    Cervical cancer continues to be the commonest cause of death among women in developing countries, largely due to the failure to the inability to sustain effective cytology-based screening programs. While this burden may come down following implementation of the human papillomavirus (HPV) vaccine, screening will still be required. HPV DNA testing is a promising new technology for cervical cancer prevention and is the most reproducible of all cervical cancer screening tests. Presently, the two assays most widely used for the detection of genital types are the polymerase chain reaction (PCR) and Hybrid Capture 2 assays (hc2). Rapid, affordable tests are expected to be available soon. HPV DNA testing can be used in a variety of clinical scenarios that include primary screening in women older than 30 yr; as an adjunctive test to cytology; in the triage of women with an equivocal cytologic report, e.g., ASC-US; or for follow-up post-treatment for cervical intraepithelial neoplasia (CIN). HPV DNA testing can also be performed on self-collected samples, which allows screening in remote areas and also in women who refuse gynecologic examination.

  19. Screening for tuberculosis and testing for human immunodeficiency virus in Zambian prisons

    Science.gov (United States)

    Maggard, Katie R; Hatwiinda, Sisa; Harris, Jennifer B; Phiri, Winifreda; Krüüner, Annika; Kaunda, Kaunda; Topp, Stephanie M; Kapata, Nathan; Ayles, Helen; Chileshe, Chisela; Henostroza, German

    2015-01-01

    Abstract Objective To improve the Zambia Prisons Service’s implementation of tuberculosis screening and human immunodeficiency virus (HIV) testing. Methods For both tuberculosis and HIV, we implemented mass screening of inmates and community-based screening of those residing in encampments adjacent to prisons. We also established routine systems – with inmates as peer educators – for the screening of newly entered or symptomatic inmates. We improved infection control measures, increased diagnostic capacity and promoted awareness of tuberculosis in Zambia’s prisons. Findings In a period of 9 months, we screened 7638 individuals and diagnosed 409 new patients with tuberculosis. We tested 4879 individuals for HIV and diagnosed 564 cases of infection. An additional 625 individuals had previously been found to be HIV-positive. Including those already on tuberculosis treatment at the time of screening, the prevalence of tuberculosis recorded in the prisons and adjacent encampments – 6.4% (6428/100 000) – is 18 times the national prevalence estimate of 0.35%. Overall, 22.9% of the inmates and 13.8% of the encampment residents were HIV-positive. Conclusion Both tuberculosis and HIV infection are common within Zambian prisons. We enhanced tuberculosis screening and improved the detection of tuberculosis and HIV in this setting. Our observations should be useful in the development of prison-based programmes for tuberculosis and HIV elsewhere. PMID:25883402

  20. Developing Save Your Food Kit (Sayofu Kit) to Support Inquiry, Improve Student Learning Outcomes at SMP Plus Hidayatul Mubtadiin and Public Awareness on Food Additives

    Science.gov (United States)

    Astutik, J.

    2017-02-01

    Food additives are materials that can not be separated from the lives of students and the community. Based on the preliminary questionnaire, it indicates the lack of kit supporting material additives in some schools and communities. The research objectives of this development are (1) to develop Kit experiment (SAYOFU KIT) and supplementary books to improve student learning outcomes in the classroom and public awareness on food additives (2) to describe the feasibility and potential effectiveness of SAYOFU KIT developed (3) to analyze the practice of SAYOFU KIT and benefits for students and the community. This development study uses 4-D models Thiagarajan, et al (1974). Through some stages, they are: defining, designing, developing and disseminating which involes the students and community. The developed SAYOFU KIT includes additives sample kit, borax test kit, curcumin test kit, formaldehyde test kit, modification heater to the identification of dyes and dye test paper. The study is conducted at SMP Plus Hidayatul Mubtadiin, and TKIT Al Uswah. The products are validated by experts and education practitioners. Qualitative data processing uses descriptive method, whereas quantitative data by using the N-gain. The average yield of expert validation of SAYOFU KIT with supplementary books 76.50% teacher’s book and 76.30% student’s book are eligible. The average yield of 96.81% validation of educational practitioners criteria, piloting a small group of 83.15%, and 82.89% field trials are very decent. The average yield on the student questionnaire responses SAYOFU kit and supplementary book is 87.6% with the criteria very well worth it. N-Gain 0:56 cognitive achievement with the criteria enough. The results of the public poll showed 95% feel the benefits SAYOFU kits for testing food. Based from description indicates that SAYOFU Kit developed feasible, practical, useful to support inquiry learning and improve student learning outcomes as well as public awareness of

  1. Comparative Evaluation of Seven Commercial Tests for Detection of Heterophile Antibody in Infectious Mononucleosis

    Directory of Open Access Journals (Sweden)

    Martin Skulnick

    1992-01-01

    Full Text Available Detection of heterophile antibodies in infectious mononucleosis is the most rapid and cost-effective method for confirming the clinical diagnosis of the disease. This study compared seven commercial test kits (the Oxoid Infectious Mononucleosis Kit [Oxoid Ltd], Immunoscan Im-Latex [Baxter Travenol], Mono-Latex [Wampole Laboratories], Monospot and Im Screen Test [Ortho Diagnostics], Immunoscan Im-RBC Test [Baxter Travenol], and Infectious Mononucleosis Test [NCS Diagnostics] to the Davidsohn differential test. All of the kits were shown to be acceptable for use, with specificities and sensitivities greater than 96.5% and 95.5%, respectively.

  2. Correlation of Michigan neuropathy screening instrument, United Kingdom screening test and electrodiagnosis for early detection of diabetic peripheral neuropathy.

    Science.gov (United States)

    Fateh, Hamid R; Madani, Seyed Pezhman; Heshmat, Ramin; Larijani, Bagher

    2015-01-01

    Almost half of Diabetic Peripheral Neuropathies (DPNs) are symptom-free. Methods including questionnaires and electrodiagnosis (EDx) can be fruitful for easy reach to early diagnosis, correct treatments of diabetic neuropathy, and so decline of complications for instance diabetic foot ulcer and prevention of high costs. The goal of our study was to compare effectiveness of the Michigan neuropathy screening instrument (MNSI), United Kingdom screening test (UKST) and electrophysiological evaluation in confirming diabetic peripheral neuropathy. One hundred twenty five known diabetes mellitus male and female subjects older than 18 with or without symptoms of neuropathy comprised in this research. All of them were interviewed in terms of demographic data, lipid profile, HbA1C, duration of disease, and history of retinopathy, so examined by Michigan neuropathy screening instrument (MNSI), United Kingdom screening test (UKST), and nerve conduction studies (NCS). The collected data were analyzed by SPSS software 18. One hundred twenty five diabetic patients (70 female, 55 male) were recruited in this study with a mean age of 58.7 ± 10.2, and mean duration of diabetes was 10.17 ± 6.9 years. The mean neuropathy score of MNSI and UKST were 2.3 (1.7) and 4.16 (2.9), respectively. Each instrument detected the peripheral neuropathy in 78 (69 %) and 91 (73 %) of patients, respectively. There was a significant relationship between number of neuropathies and mean of diabetes duration and development of retinopathy in both questionnaire evaluations and NCS. By nerve conduction study, neuropathy was detected in 121 (97 %) diabetic patients were reported in order 15 (12 %) mononeuropathy (as 33 % sensory and 67 % motor neuropathy) and 106 (85 %) polyneuropathy (as 31 % motor and 69 % sensorimotor neuropathy). As regards NCS is an objective, simple, and non-invasive tool and also can determine level of damage and regeneration in peripheral nerves, this study

  3. Cervical human papilloma virus (HPV) DNA primary screening test: Results of a population-based screening programme in central Italy.

    Science.gov (United States)

    Passamonti, Basilio; Gustinucci, Daniela; Giorgi Rossi, Paolo; Cesarini, Elena; Bulletti, Simonetta; Carlani, Angela; Martinelli, Nadia; Broccolini, Massimo; D'Angelo, Valentina; D'Amico, Maria Rosaria; Di Dato, Eugenio; Galeazzi, Paola; Malaspina, Morena; Spita, Nicoletta; Tintori, Beatrice; Giaimo, Maria Donata

    2017-09-01

    Objective To present the results of the first and second round human papilloma virus (HPV)-based screening programme in the Umbria region after three years. Methods From August 2010 to November 2011, the entire female population aged 35-64 in a local health district was invited for HPV testing (HPV-DNA cobas4800 on a liquid-based cytology sample). HPV-negative women were re-invited after three years. For HPV-positive women, a slide was prepared and interpreted. Positive cytologies were referred to colposcopy; negatives were referred to repeat HPV after one year. If HPV was persistently positive, women were referred to colposcopy; if negative, to normal screening. Indicators of the first and second round are compared with those of cytology screening in the same area in the preceding three years. Results Participation was 56.5%, the same as cytology (56.6%). HPV-positivity was 6.4% (396/6272), cytology triage positivity was 35.6%; 251 cytology negative women were referred to one-year HPV retesting, 84.1% complied, and 55.5% were positive. Total colposcopy referral was 4.1%, and for cytology 1%. The detection rate for cervical intraepithelial neoplasia grade 2 or more severe was 10‰, compared with 3.7‰ using cytology. After three years, HPV-positivity was 3.4% (129/3831), overall colposcopy referral was 2.3% (most at one-year follow-up), and detection rate was 0.5/1000. Conclusions The first round detection rate was more than twice that of cytology screening, while colposcopy referral increased fourfold. At the second round, the detection rate decreased dramatically, showing that longer interval and more conservative protocols are needed.

  4. Detection of complex hemoglobinopathies: recommendations on screening and DNA testing

    Directory of Open Access Journals (Sweden)

    E. Baysal

    2011-12-01

    Full Text Available The following recommendations should be taken into account during the evaluation and elucidation of the complex hemoglobinopathies: a in complex hemoglobinopathies performing DNA studies on all family members might be essential; b complex gene-gene interactions offer major diagnostic challenges both at the technical and clinical level; c hematological & DNA analyses must be run in parallel. Some cases may be straight forward but others may require indepth DNA work-up; d co-inheritance of a-thalassemia offers added challenge as it may affect phenotype significantly; e sickle cell anemia (SS, co-inherited with a-thal, can be a phenocopy of Sβ0-thal. The HbA2 increase can be mistaken for Sβ-thal. DNA Sequencing is imperative; f only a selected number of normal MCV, MCH, borderline HbA2 cases must be referred for DNA analysis. However, in certain cases, following hematological and family evaluation, the β and d genes may need to be sequenced; g DNA Sequencing will increasingly become the method of choice for screening and DNA mutation analysis. However, new methods like MLPA-which analyzes gene dosage- must be used more commonly to rule out deletion mutants to avoid false negative sequencing results; h these recommendations should be reviewed every 2-3 years reflecting new methods, new findings and new findings from ethnic groups. 诊断和说明复杂血红蛋白病时,建议考虑以下几点: a)针对复杂的血红蛋白病,有必要对所有家庭成员开展DNA研究;b 复杂的基因-基因交互作用可能使诊断在技术和临床层面上颇受挑战;c 血液和DNA分析须同时进行。 有些病例简单,但另外一些病例可能需要开展深层次的DNA检查;d 由于α型地中海贫血可能严重影响表型,α型地中海贫血的共同继承特征更具挑战;e 共同继承α型地中海贫血的镰状细胞贫血(SS),可以作为Sβ0型地中海贫血的显型。 HbA2增

  5. "Chair Stand Test" as Simple Tool for Sarcopenia Screening in Elderly Women.

    Science.gov (United States)

    Pinheiro, P A; Carneiro, J A O; Coqueiro, R S; Pereira, R; Fernandes, M H

    2016-01-01

    To investigate the association between sarcopenia and "chair stand test" performance, and evaluate this test as a screening tool for sarcopenia in community-dwelling elderly women. Cross-sectional Survey. 173 female individuals, aged ≥ 60 years and living in the urban area of the municipality of Lafaiete Coutinho, Bahia's inland, Brazil. The association between sarcopenia (defined by muscle mass, strength and/or performance loss) and performance in the "chair stand test" was tested by binary logistic regression technique. The ROC curve parameters were used to evaluate the diagnostic power of the test in sarcopenia screening. The significance level was set at 5 %. The model showed that the time spent for the "chair stand test" was positively associated (OR = 1.08; 95% CI = 1.01 - 1.16, p = 0.024) to sarcopenia, indicating that, for each 1 second increment in the test performance, the sarcopenia's probability increased by 8% in elderly women. The cut-off point that showed the best balance between sensitivity and specificity was 13 seconds. The performance of "chair stand test" showed predictive ability for sarcopenia, being an effective and simple screening tool for sarcopenia in elderly women. This test could be used for screening sarcopenic elderly women, allowing early interventions.

  6. An evaluation of the Oxoid Biochemical Identification System Campy rapid screening test for Campylobacteraceae and Helicobacter spp.

    Science.gov (United States)

    Hoosain, N; Lastovica, A J

    2009-06-01

    To evaluate the Oxoid Biochemical Identification System (OBIS) Campy test (ID0800M) against Campylobacter; Arcobacter; and other micro-organisms, with similar colonial morphology, for the detection of l-alanine aminopeptidase (l-ALA). The KOH and l-ALA (OBIS and Fluka) tests were carried out on every isolate. The procedures were followed as indicated in the OBIS and Fluka kit instructions. A total of 146 strains of 19 species of Campylobacter, seven strains of Arcobacter butzleri, four Arcobacter butzleri-like strains, 42 strains of 10 species of Helicobacter, 96 Gram-negative and 49 Gram-positive clinical isolates were tested. As expected, Campylobacter and Arcobacter strains were negative, while other Gram-negative bacteria were positive for the l-ALA test. An unexpected finding was that Helicobacter strains, although Gram-negative, were all negative for the l-ALA tests suggesting the absence of l-ALA within this genus. This is a novel finding. The absence of l-ALA was confirmed upon comparison with the available full genomic sequences of Helicobacter on the NCBI database. The OBIS Campy (ID0800M) test kit proved to be rapid and accurate for the presumptive characterization of Campylobacter and Arcobacter. A novel finding was that Helicobacter species also did not have the l-ALA enzyme. The OBIS kit will be useful in diagnostic laboratories for the presumptive diagnosis of Campylobacter, Arcobacter and Helicobacter strains.

  7. Estimation of diagnostic performance of dementia screening tests: Mini-Mental State Examination, Mini-Cog, Clock Drawing test and Ascertain Dementia 8 questionnaire.

    Science.gov (United States)

    Yang, Li; Yan, Jing; Jin, Xiaoqing; Jin, Yu; Yu, Wei; Xu, Shanhu; Wu, Haibin; Xu, Ying; Liu, Caixia

    2017-05-09

    Dementia is one of the leading causes of dependence in the elderly. This study was conducted to estimate diagnostic performance of dementia screening tests including Mini-Mental State Examination (MMSE), Mini-Cog, Clock Drawing Test (CDT) and Ascertain Dementia 8 questionnaire (AD8) by Bayesian models. A total of 2015 participants aged 65 years or more in eastern China were enrolled. The four screening tests were administered and scored by specifically trained psychiatrists. The prior information of sensitivity and specificity of every screening test was updated via Bayes' theorem to a posterior distribution. Then the results were compared with the estimation based on National Institute of Aging-Alzheimer's Association criteria (NIA-AA). The diagnostic characteristics of Mini-Cog, including sensitivity, specificity, PPV, NPV, especially the Youden index, performed well, even better than the combinations of several screening tests. The Mini-Cog with excellent screening characteristics, spending less time, could be considered to be used as a screening test to help to screen patients with cognitive impairment or dementia early. And Bayesian method was shown to be a suitable tool for evaluating dementia screening tests. The Mini-Cog with excellent screening characteristics, spending less time, could be considered to be used as a screening test to help to screen patients with cognitive impairment or dementia early. And Bayesian method was shown to be a suitable tool for evaluating dementia screening tests.

  8. [An experimental proficiency test for ability to screen 104 residual pesticides in agricultural products].

    Science.gov (United States)

    Tsumura, Yukari; Ishimitsu, Susumu; Otaki, Kayo; Uchimi, Hiroyuki; Matsumoto, Nobuyuki; Daba, Masaki; Tsuchiya, Tetsu; Ukyo, Masaho; Tonogai, Yasuhide

    2003-10-01

    An experimental proficiency test program for ability to screen 104 residual pesticides in agricultural products has been conducted. Eight Japanese laboratories joined the program. Items tested in the present study were limit of detection, internal proficiency test (self spike) and external proficiency test (blind spike). All 104 pesticides were well detected and recovered from agricultural foods in the internal proficiency test. However, the results of the external proficiency test did not completely agree with those of the internal proficiency tests. After 5 rounds of the blind spike test, the ratio of the number of correctly detected pesticides to that of actually contained ones (49 total) ranged from 65% to 100% among laboratories. The numbers of mistakenly detected pesticides by a laboratory were 0 to 15. Thus, there was a great difference among the laboratories in the ability to screen multiresidual pesticides.

  9. Screen Channel Liquid Acquisition Device Outflow Tests in Liquid Hydrogen

    Science.gov (United States)

    Hartwig, Jason W.; Chato, David J.; McQuillen, J. B.; Vera, J.; Kudlac, M. T.; Quinn, F. D.

    2013-01-01

    This paper presents experimental design and test results of the recently concluded 1-g inverted vertical outflow testing of two 325x2300 full scale liquid acquisition device (LAD) channels in liquid hydrogen (LH2). One of the channels had a perforated plate and internal cooling from a thermodynamic vent system (TVS) to enhance performance. The LADs were mounted in a tank to simulate 1-g outflow over a wide range of LH2 temperatures (20.3 - 24.2 K), pressures (100 - 350 kPa), and flow rates (0.010 - 0.055 kg/s). Results indicate that the breakdown point is dominated by liquid temperature, with a second order dependence on mass flow rate through the LAD. The best performance is always achieved in the coldest liquid states for both channels, consistent with bubble point theory. Higher flow rates cause the standard channel to break down relatively earlier than the TVS cooled channel. Both the internal TVS heat exchanger and subcooling the liquid in the propellant tank are shown to significantly improve LAD performance.

  10. Eficiência dos testes COPAN (Microplate e Single na detecção de resíduos de antimicrobianos no leite Efficacy of COPAN (Microplate and Single kits in detection of antimicrobials residues in milk

    Directory of Open Access Journals (Sweden)

    C.G.M.S.C. Tenório

    2009-04-01

    Full Text Available Avaliou-se a eficiência dos testes microbiológicos COPAN (Microplate e Single para detecção de resíduos de 13 antimicrobianos inoculados em leite isento de resíduos. Foram utilizadas quatro concentrações, sendo a primeira equivalente à metade do limite de detecção declarado pelo fabricante (C1; a segunda equivalente ao limite máximo de resíduos (LMR estabelecido pela legislação brasileira (C2; a terceira equivalente ao limite de detecção declarado pelo fabricante (C3; e a quarta equivalente ao dobro do limite de detecção declarado pelo fabricante (C4. Os testes apresentaram 100% de sensibilidade na detecção de amoxicilina, ampicilina, cloxacilina, penicilina, tilosina, sulfadiazina, sulfametoxazol, e 96,7% na detecção de oxacilina para as concentrações informadas pelo fabricante como limite de detecção. Em relação às concentrações estabelecidas pela legislação brasileira, verificou-se que os testes foram capazes de detectá-las para a maioria dos antimicrobianos avaliados. Os testes não se mostraram eficientes na detecção das concentrações estabelecidas pela legislação para eritromicina, oxitetraciclina, tetraciclina, trimetoprim e gentamicina (Microplate.The efficacy of the microbiological kits COPAN (Microplate and Single for detection of antimicrobials residues was tested. Thirteen drugs were inoculated into milk without residues at four concentration levels: C1 - half of the detection threshold declared by the manufacturer, C2 - the maximum residues threshold established by the Brazilian legislation, C3 - the detection threshold declared by the manufacturer, and C4 - two fold the detection threshold declared by the manufacturer. The tests showed 100% efficient in detection of amoxicillin, cloxacillin, penicillin, tilosin, sulfadiazine, and sulfa methoxazol; and 96.7% for oxacillin considering the concentration stated by the manufacturer as threshold level. Regarding the concentrations established by

  11. [Human papillomavirus testing in cervical cancer screening at a public health service of Santiago, Chile].

    Science.gov (United States)

    Terrazas, Solana; Ibáñez, Carolina; Lagos, Marcela; Poggi, Helena; Brañes, Jorge; Barriga, María Isabel; Cartagena, Jaime; Núñez, Felipe; González, Francisca; Cook, Paz; Van De Wyngard, Vanessa; Ferreccio, Catterina

    2015-01-01

    Molecular techniques for human papillomavirus (HPV) detection have a good performance as screening tests and could be included in cervical cancer early detection programs. We conducted a population-based trial comparing HPV detection and Papanicolaou as primary screening tests, in a public health service in Santiago, Chile. To describe the experience of implementing this new molecular test and present the main results of the study. Women aged 25 to 64 enrolled in three public health centers were invited to participate. In all women, samples were collected for Papanicolaou and HPV DNA testing, and naked-eye visual inspection of the cervix with acetic acid was performed. Women with any positive screening test were referred to the local area hospital for diagnostic confirmation with colposcopy and biopsy of suspicious lesions. Screening results were obtained for 8265 women, of whom 931 (11.3%) were positive to any test. The prevalence of cervical intraepithelial neoplasia grade 2 or worse (CIN2+) was 1.1%; nine women had invasive cervical cancer. Sensitivities for the detection of CIN2+ were 22.1% (95% confidence interval (CI) 16.4-29.2) for Papanicolaou and 92.7% (95% CI 84.4-96.8) for HPV testing; specificities were 98.9% (95% CI 98.7-99.0) and 92.0% (95% CI 91.4-92.6) respectively. This experience showed that the implementation of a molecular test for cervical cancer screening is not a major challenge in Chile: it was well accepted by both the health team and the participants, and it may improve the effectiveness of the screening program.

  12. Assessment of Prospective Memory – a Validity Study of Memory for Intentions Screening Test

    NARCIS (Netherlands)

    Bezdicek, O.; Raskin, S.A.; Altgassen, A.M.; Ruzicka, E.

    2014-01-01

    Aim: The goal of the present study was to validate the Czech version of the Memory for Intentions (Screening) Test (MIST, 2010). We included standardized testing material, translation of administration and scoring, and assessment of normative data for the MIST in the Czech population. Introduction:

  13. Restriction of human papillomavirus DNA testing in primary cervical screening to women above age 30

    DEFF Research Database (Denmark)

    Rebolj, Matejka; Njor, Sisse H; Lynge, Elsebeth

    2012-01-01

    Cervical screening with human papillomavirus (HPV) testing is less specific for high-grade cervical intraepithelial neoplasia (=CIN3) than cytology. The aim of this systematic review was to determine whether a restriction of HPV testing to women aged at least 30 years would eliminate the problem...

  14. Memory-Context Effects of Screen Color in Multiple-Choice and Fill-In Tests

    Science.gov (United States)

    Prestera, Gustavo E.; Clariana, Roy; Peck, Andrew

    2005-01-01

    In this experimental study, 44 undergraduates completed five computer-based instructional lessons and either two multiplechoice tests or two fill-in-the-blank tests. Color-coded borders were displayed during the lesson, adjacent to the screen text and illustrations. In the experimental condition, corresponding border colors were shown at posttest.…

  15. Noninvasiv prænatal test er et gennembrud inden for prænatal screening

    DEFF Research Database (Denmark)

    Hornstrup, Louise Stig; Ambye, Louise; Sørensen, Steen

    2016-01-01

    Non-invasive prenatal testing is a breakthrough in prenatal screening Non-invasive prenatal testing (NIPT) using cell-free fetal DNA from the peripheral blood of the pregnant woman has become a possibility within recent years, but is not yet implemented in Denmark. NIPT has proven to be very...

  16. Cross-sectional evaluation of an internet-based hearing screening test in an occupational setting

    NARCIS (Netherlands)

    Sheikh Rashid, Marya; Leensen, Monique Cj; de Laat, Jan Apm; Dreschler, Wouter A.

    2017-01-01

    Objectives The Occupational Earcheck (OEC) is an online internet test to detect high-frequency hearing loss for the purposes of occupational hearing screening. In this study, we evaluated the OEC in an occupational setting in order to assess test sensitivity, specificity, and validity. Methods A

  17. Elevated phenylalanine on newborn screening: follow-up testing may reveal undiagnosed galactosaemia.

    Science.gov (United States)

    Shakespeare, Lynette; Downing, Melanie; Allen, Joyce; Casbolt, Ann-Marie; Ellin, Sheila; Maloney, Martin; Race, Gillian; Bonham, Jim

    2010-11-01

    Introduction Newborn screening for phenylketonuria (PKU) can reveal other conditions which lead to an increased blood spot phenylalanine (Phe) concentration. We have investigated the proportion of blood spot samples that gave a positive screen due to clinically significant conditions other than PKU, compared the positive predictive value (PPV) of our referral Phe cut-off with that recommended by the UK Newborn Screening Programme Centre (UKNSPC) (>210 and >240 μmol/L, respectively) and evaluated the effectiveness of reflex testing for galactosaemia using a lower blood spot Phe cut-off concentration of 130 μmol/L. All blood spot samples that screened positive, for an increased Phe concentration, between April 2001 and March 2008, were identified from the records of the Sheffield Newborn Screening Laboratory and the diagnoses noted. In addition, all cases of galactosaemia detected in or notified to our screening laboratory within this time were also examined and the screened Phe concentrations compared. Out of 438,674 babies who were screened, 67 had Phe concentration >210 μmol/L (15 per 100,000). Of these, 40 had PKU or persistent hyperphenylalaninaemia with a Phe concentration identified by screening between 270 and 2350 μmol/L. A further 11 were diagnosed with another clinically significant disorder: galactosaemia (n = 8), biopterin defects (n = 2), tyrosinaemia Type 1 (n = 1). In addition, 16 had transient elevations in Phe. In total, nine cases of galactosaemia were identified, of whom, three had Phe concentrations 240 μmol/L) will not affect the detection rate of classical PKU, but will improve the PPV from 76% to 80%. The use of a lower cut-off (130 μmol/L) for reflex galactosaemia testing enables the timely identification of asymptomatic cases that benefit particularly from early treatment, without prompting any unnecessary clinical referrals or delaying any referrals. This intervention may reduce mortality in this vulnerable group.

  18. Dumpster Optics: teaching and learning optics without a kit

    Science.gov (United States)

    Donnelly, Judy; Magnani, Nancy; Robinson, Kathleen

    2016-09-01

    The Next Generation Science Standards (NGSS) and renewed emphasis on STEM education in the U.S. have resulted in the development of many educational kits for teaching science in general and optics in particular. Many teachers do not have funding to purchase kits and practical experience has shown that even costly kits can have poorly written and misleading instructions and may include experiments that would not work in a classroom. Dumpster Optics lessons are designed to use inexpensive, commonly found materials. All lessons have been field-tested with students. We will describe the development of the lessons, provide examples of field testing experiences and outline possible future activities.

  19. Captopril renal scan - a noninvasive screening test for renovascular hypertension

    International Nuclear Information System (INIS)

    Akhter, M.S.

    2001-01-01

    Captopril renal scan is simple, noninvasive and cost-effective test for the initial diagnosis with the sensitivity of 98%. Renal scan with Tc-99m DTPA was performed on the suspected patient one hour after oral intake of 25 mg of captopril. Relative renal function, renogram curves and GFR for both the kidneys were calculated by computer software. Right kidney was small in size, showed relative renal function of 12% and the GFR was 9.64 ml/min. The left organ revealed relative function of 88% and the GFR was 72.12 ml/min. There was marked difference in renogram peaks. On baseline study, the right kidney showed marked improvement of renogram curve peak and the renal function improved to 23% while the GFR showed rise to 19 ml/min. In comparison with baseline findings, the right kidney, in response to ACE inhibitor showed deterioration of renogram peak, 47.8% deterioration of relative renal function and 49.2% fall in GFR. Major criteria for renovascular cause was fulfilled and the patient was labeled for having high probability for renal artery stenosis. Renal angiography, later on confirmed the diagnosis. (author)

  20. The triple test as a screening technique for Down syndrome: reliability and relevance

    Directory of Open Access Journals (Sweden)

    Tim Reynolds

    2010-05-01

    Full Text Available Tim ReynoldsClinical Chemistry Department, Queen’s Hospital, Burton-on-Trent, Staffordshire, UKAbstract: The triple test is a second trimester screening test used to identify those pregnant women who should be offered a diagnostic test to identify whether their fetus has an aneuploidy. It was first described in 1988, but has largely been superseded by newer tests either conducted earlier in the first trimester (ie, the combined test, using ultrasound measurement of nuchal translucency,pregnancy-associated plasma protein A, and human chorionic gonadotrophin [hCG] or in the second trimester (ie, the quadruple test, using α-fetoprotein, hCG, uE3, and inhibin. These newer tests have been introduced because they offer greater detection and lower screen positive results thereby enhancing diagnosis rates, while decreasing the risk of iatrogenic harm caused by the invasive testing required when collecting suitable sample tissue. Noninvasive alternatives to the triple test have been identified, but these have not been adopted despite 13 years of development. It is likely, therefore, that the triple test (or variants thereof will continue to be used in routine antenatal care for the foreseeable future.Keywords: pregnancy, screening test, antenatal, Down syndrome

  1. Radiology seminars using teaching kits

    International Nuclear Information System (INIS)

    Munro, T.G.

    1989-01-01

    Clinco-radiological seminars are an effective method of teaching medical students. However, in busy departments it is often difficult to provide enough radiologists for small group instruction. This can be facilitated by the use of prepared teaching kits. Each kit contains a set of duplicated films and a syllabus which gives a short clinical history for each patient and a series of questions to be used to direct the discussion. Each diagnostic problem is chosen to demonstrate core material. We have been using these teaching kits for organ system teaching in the preclerkship year. Teaching kits offer several advantages. They make it easier to recruit seminar leaders through efficient use of their time. The use of duplicated films and a syllabus ensures that all students cover the same material. The syllabus can be used to generate examination questions for reinforcement of important concepts. The kits are also available to students to review alone and can be readily updated as required

  2. Do negative screening test results cause false reassurance? A systematic review.

    Science.gov (United States)

    Cooper, Grace C; Harvie, Michelle N; French, David P

    2017-11-01

    It has been suggested that receiving a negative screening test result may cause false reassurance or have a 'certificate of health effect'. False reassurance in those receiving a negative screening test result may result in them wrongly believing themselves to be at lower risk of the disease, and consequently less likely to engage in health-related behaviours that would lower their risk. The present systematic review aimed to identify the evidence regarding false reassurance effects due to negative screening test results in adults (over 18 years) screened for the presence of a disease or its precursors, where disease or precursors are linked to lifestyle behaviours. MEDLINE and PsycINFO were searched for trials that compared a group who had received negative screening results to an unscreened control group. The following outcomes were considered as markers of false reassurance: perceived risk of disease; anxiety and worry about disease; health-related behaviours or intention to change health-related behaviours (i.e., smoking, diet, physical activity, and alcohol consumption); self-rated health status. Nine unique studies were identified, reporting 55 measures in relation to the outcomes considered. Outcomes were measured at various time points from immediately following screening to up to 11 years after screening. Despite considerable variation in outcome measures used and timing of measurements, effect sizes for comparisons between participants who received negative screening test results and control participants were typically small with few statistically significant differences. There was evidence of high risk of bias, and measures of behaviours employed were often not valid. The limited evidence base provided little evidence of false reassurance following a negative screening test results on any of four outcomes examined. False reassurance should not be considered a significant harm of screening, but further research is warranted. Statement of contribution

  3. A focus group study of consumer attitudes toward genetic testing and newborn screening for deafness.

    Science.gov (United States)

    Burton, Sarah K; Withrow, Kara; Arnos, Kathleen S; Kalfoglou, Andrea L; Pandya, Arti

    2006-12-01

    Progress in identifying genes for deafness together with implementation of universal audiologic screening of newborns has provided the opportunity for more widespread use of molecular tests to detect genetic forms of hearing loss. Efforts to assess consumer attitudes toward these advances have lagged behind. Consumer focus groups were held to explore attitudes toward genetic advances and technologies for hearing loss, views about newborn hearing screening, and reactions to the idea of adding molecular screening for hearing loss at birth. Focus group discussions were recorded, transcribed and analyzed. Five focus groups with 44 participants including hearing parents of deaf children, deaf parents and young deaf adults were held. Focus group participants supported the use of genetic tests to identify the etiology of hearing loss but were concerned that genetic information might influence reproductive decisions. Molecular newborn screening was advocated by some; however, others expressed concern about its effectiveness. Documenting the attitudes of parents and other consumers toward genetic technologies establishes the framework for discussions on the appropriateness of molecular newborn screening for hearing loss and informs specialists about potential areas of public education necessary prior to the implementation of such screening.

  4. Programming with the KIBO Robotics Kit in Preschool Classrooms

    Science.gov (United States)

    Elkin, Mollie; Sullivan, Amanda; Bers, Marina Umaschi

    2016-01-01

    KIBO is a developmentally appropriate robotics kit for young children that is programmed using interlocking wooden blocks; no screens or keyboards are required. This study describes a pilot KIBO robotics curriculum at an urban public preschool in Rhode Island and presents data collected on children's knowledge of foundational programming concepts…

  5. Risk factors for false positive and for false negative test results in screening with fecal occult blood testing

    NARCIS (Netherlands)

    Stegeman, Inge; de Wijkerslooth, Thomas R.; Stoop, Esther M.; van Leerdam, Monique; van Ballegooijen, M.; Kraaijenhagen, Roderik A.; Fockens, Paul; Kuipers, Ernst J.; Dekker, Evelien; Bossuyt, Patrick M.

    2013-01-01

    Differences in the risk of a false negative or a false positive fecal immunochemical test (FIT) across subgroups may affect optimal screening strategies. We evaluate whether subgroups are at increased risk of a false positive or a false negative FIT result, whether such variability in risk is

  6. Speech-in-noise screening tests by internet, part 3: test sensitivity for uncontrolled parameters in domestic usage

    NARCIS (Netherlands)

    Leensen, Monique C. J.; Dreschler, Wouter A.

    2013-01-01

    The online speech-in-noise test 'Earcheck' is sensitive for noise-induced hearing loss (NIHL). This study investigates effects of uncontrollable parameters in domestic self-screening, such as presentation level and transducer type, on speech reception thresholds (SRTs) obtained with Earcheck.

  7. Prospective evaluation of the diagnostic value of sensitive KIT D816V mutation analysis of blood in adults with suspected systemic mastocytosis

    DEFF Research Database (Denmark)

    Kielsgaard Kristensen, Thomas; Vestergaard, H; Bindslev-Jensen, C

    2017-01-01

    BACKGROUND: Sensitive KIT D816V mutation analysis of blood has been proposed to guide bone marrow (BM) investigation in suspected systemic mastocytosis (SM). The aim of this prospective study was for the first time to compare the D816V status of the "screening blood sample" used to guide BM biopsy...... in suspected SM to the outcome of the subsequent BM investigation. METHODS: Fifty-eight adult patients with suspected SM were included. The outcome of sensitive KIT D816V analysis of blood was compared to the result of the BM investigation. RESULTS: Screening blood samples from 44 of 58 patients tested D816V...... patients did not fulfill any diagnostic SM criteria (excluding tryptase criterion). Of the 48 SM patients, 90% tested D816V-positive. Thirteen SM patients presented with Hymenoptera venom-induced anaphylaxis, no skin lesions, and baseline serum tryptase ≤20 ng/mL. Of these, 92% tested D816V...

  8. Syringe test screening of microbial gas production activity: Cases denitrification and biogas formation.

    Science.gov (United States)

    Østgaard, Kjetill; Kowarz, Viktoria; Shuai, Wang; Henry, Ingrid A; Sposob, Michal; Haugen, Hildegunn Hegna; Bakke, Rune

    2017-01-01

    Mass produced plastic syringes may be applied as vessels for cheap, simple and large scale batch culture testing. As illustrated for the cases of denitrification and of biogas formation, metabolic activity was monitored by direct reading of the piston movement due to the gas volume formed. Pressure buildup due to friction was shown to be moderate. A piston pull and slide back routine can be applied before recording gas volume to minimize experimental errors due to friction. Inoculum handling and activity may be conveniently standardized as illustrated by applying biofilm carriers. A robust set of positive as well as negative controls ("blanks") should be included to ensure quality of the actual testing. The denitrification test showed saturation response at increasing amounts of inoculum in the form of adapted moving bed biofilm reactor (MBBR) carriers, with well correlated nitrate consumption vs. gas volume formed. As shown, the denitrification test efficiently screened different inocula at standardized substrates. Also, different substrates were successfully screened and compared at standardized inocula. The biogas potential test showed efficient screening of different substrates with effects of relative amounts of carbohydrate, protein, fat. A second case with CO 2 capture reclaimer waste as substrate demonstrated successful use of co-feeding to support waste treatment and how temperature effects on kinetics and stoichiometry can be observed. In total, syringe test screening of microbial gas production seems highly efficient at a low cost when properly applied. Copyright © 2016 Elsevier B.V. All rights reserved.

  9. Determinants of participation in colorectal cancer screening with faecal occult blood testing

    DEFF Research Database (Denmark)

    von Euler-Chelpin, My; Brasso, Klaus; Lynge, Elsebeth

    2009-01-01

    BACKGROUND: Colorectal cancer is one of the most common cancers in men and women. Participation rates in faecal occult blood testing (FOBT) screening activities are, however, relatively low. In terms of lowering the colorectal cancer mortality, high participation rates are essential, and therefore......, but determinants varied across countries and test settings. There was no systematic variation in participation across age groups. CONCLUSION: The participation pattern depends in part on local circumstances, which makes it difficult to point to a general strategy for increasing the uptake in FOBT screening...

  10. Medical and lay attitudes towards genetic screening and testing in Finland

    DEFF Research Database (Denmark)

    Toiviainen, Hanna; Jallinoja, Piia; Aro, Arja R

    2003-01-01

    The purpose of this study was to compare physicians', midwives' and lay people's attitudes towards genetic screening and testing to find out whether medical education and experience influence attitudes of genetic screening and testing. The study was based on comparison of answers to joint questions...... in three different cross-sectional postal surveys between October 1996 and April 1998 in Finland. Target groups were physicians (study base n=772, response rate 74%, including gynaecologists, paediatricians, general practitioners and clinical geneticists), midwives and public health nurses (collectively...

  11. Imaging evaluation of infants with neuroblastoma detected by VMA screening spot test

    International Nuclear Information System (INIS)

    Fujioka, M.; Saiki, N.; Aihara, T.; Yamamoto, K.

    1988-01-01

    In the Saitama Prefecture in Japan, VMA (vanillyl manderic acid) screening spot test for detection of neuroblastoma has been performed in 173,046 infants in the years 1981-1986 and 15 infants were found to have neuroblastoma. Two infants had mediastinal tumors and the remainder, 13, had intraabdominal tumors. Only 7 infants had palpable masses. Although CT was documented to be the best imaging procedure to provide sufficient information for treatment, conventional radiographic examinations of the chest and abdomen, and abdominal ultrasonography were able, as initial imaging procedures, to detect reasonably small neuroblastomas in infants with a positive VMA screening test. (orig.)

  12. Liquid-Crystal Display (LCD) Screen Thermal Testing to Simulate Solar Gain

    Science.gov (United States)

    2015-12-01

    determined that shielding the screen from solar gains was the best way to avoid monitor failure. In order to accomplish this Hot Mirror glass from...side of the monitor in order to shield the monitor from the solar loading. 2.7 Test 7 – Bench Test with a 250 W Heat Lamp and Hot Mirror Glass , 1 Inch...method to shield the screen from solar loading. The Hot Mirror glass uses a glass substrate with a coating on 1 side that passes visible light, but

  13. Good laboratory practices for biochemical genetic testing and newborn screening for inherited metabolic disorders.

    Science.gov (United States)

    2012-04-06

    Biochemical genetic testing and newborn screening are essential laboratory services for the screening, detection, diagnosis, and monitoring of inborn errors of metabolism or inherited metabolic disorders. Under the Clinical Laboratory Improvement Amendments of 1988 (CLIA) regulations, laboratory testing is categorized on the basis of the level of testing complexity as either waived (i.e., from routine regulatory oversight) or nonwaived testing (which includes tests of moderate and high complexity). Laboratories that perform biochemical genetic testing are required by CLIA regulations to meet the general quality systems requirements for nonwaived testing and the personnel requirements for high-complexity testing. Laboratories that perform public health newborn screening are subject to the same CLIA regulations and applicable state requirements. As the number of inherited metabolic diseases that are included in state-based newborn screening programs continues to increase, ensuring the quality of performance and delivery of testing services remains a continuous challenge not only for public health laboratories and other newborn screening facilities but also for biochemical genetic testing laboratories. To help ensure the quality of laboratory testing, CDC collaborated with the Centers for Medicare & Medicaid Services, the Food and Drug Administration, the Health Resources and Services Administration, and the National Institutes of Health to develop guidelines for laboratories to meet CLIA requirements and apply additional quality assurance measures for these areas of genetic testing. This report provides recommendations for good laboratory practices that were developed based on recommendations from the Clinical Laboratory Improvement Advisory Committee, with additional input from the Secretary's Advisory Committee on Genetics, Health, and Society; the Secretary's Advisory Committee on Heritable Disorders in Newborns and Children; and representatives of newborn

  14. Attitudes towards colorectal cancer (CRC) and CRC screening tests among elderly Malay patients.

    Science.gov (United States)

    Al-Naggar, Redhwan A; Al-Kubaisy, Waqar; Yap, Bee W; Bobryshev, Yuri V; Osman, Muhamed T

    2015-01-01

    Colorectal cancer (CRC) is the third most common malignancy in Malaysia, where data are limited regarding knowledge and barriers in regard to CRC and screening tests. The aim of the study was to assess these parameters among Malaysians. The questionnaires were distributed in the Umra Private Hospital in Selangor. The questionnaire had four parts and covered social-demographic questions, respondent knowledge about CRC and colorectal tests, attitude towards CRC and respondentaction regarding CRC. More than half of Malay participants (total n=187) were female (57.2%) and 36.9% of them were working as professionals. The majority of the participants (93.6%) never had a CRC screening test. The study found that only 10.2% of the study participants did not consider that their chances of getting CRC were high. A high percentage of the participants (43.3%) believed that they would have good chance of survival if the cancer would be found early. About one third of the respondents did not want to do screening because of fear of cancer, and concerns of embarrassment during the procedure adversely affected attitude to CRC screening as well. Age, gender, income, family history of CRC, vegetable intake and physical activity were found to be significant determinants of knowledge on CRC. The major barriers identified towards CRC screening identified in our study were fear of pain and embarrassment. The findings have implications for understanding of similarities and differences in attitude to CRC amongst elderly patients in other cultural/ geographic regions.

  15. A single-question screening test for drug use in primary care.

    Science.gov (United States)

    Smith, Peter C; Schmidt, Susan M; Allensworth-Davies, Donald; Saitz, Richard

    2010-07-12

    Drug use (illicit drug use and nonmedical use of prescription drugs) is common but underrecognized in primary care settings. We validated a single-question screening test for drug use and drug use disorders in primary care. Adult patients recruited from primary care waiting rooms were asked the single screening question, "How many times in the past year have you used an illegal drug or used a prescription medication for nonmedical reasons?" A response of at least 1 time was considered positive for drug use. They were also asked the 10-item Drug Abuse Screening Test (DAST-10). The reference standard was the presence or absence of current (past year) drug use or a drug use disorder (abuse or dependence) as determined by a standardized diagnostic interview. Drug use was also determined by oral fluid testing for common drugs of abuse. Of 394 eligible primary care patients, 286 (73%) completed the interview. The single screening question was 100% sensitive (95% confidence interval [CI], 90.6%-100%) and 73.5% specific (95% CI, 67.7%-78.6%) for the detection of a drug use disorder. It was less sensitive for the detection of self-reported current drug use (92.9%; 95% CI, 86.1%-96.5%) and drug use detected by oral fluid testing or self-report (81.8%; 95% CI, 72.5%-88.5%). Test characteristics were similar to those of the DAST-10 and were affected very little by participant demographic characteristics. The single screening question accurately identified drug use in this sample of primary care patients, supporting the usefulness of this brief screen in primary care.

  16. Evaluation of the localization auditory screening test in children 6-18 months of age.

    Science.gov (United States)

    Tillis, C H; Grimm, W A

    1978-01-01

    The present paper is a report of a project to develop an automated auditory screening test for infants six to 18 months of age. The first year of the project was devoted to developing equipment and test procedures; the second year was concerned with testing the effectiveness of the equipment and procedures on an actual population of six to 18 month old infants. Two-hundred and fifty infants were screened auditorily as part of a county health department child development clinic. The pass/fail results of the screening test were evaluated in terms of physical and developmental examination following the screening and by means of a case review of the child's previous history. The results indicate that the procedure under investigation can be used to differentiate the normal hearing infant from the infant with possible hearing problems. It is shown by the test environment in which this study was conducted that the procedure reported can be successfully incorporated into a public health program, i.e., child development clinics or EPSDT programs.

  17. Screening Tests

    Science.gov (United States)

    ... hazardous or risky drinking. Two instruments in particular, the AUDIT and the CAGE, are cited throughout this issue— ... drinking in a very specific population—pregnant women. The AUDIT, CAGE, and T-ACE are presented here in ...

  18. Toward Joint Hypothesis-Tests Seismic Event Screening Analysis: Ms|mb and Event Depth

    Energy Technology Data Exchange (ETDEWEB)

    Anderson, Dale [Los Alamos National Laboratory; Selby, Neil [AWE Blacknest

    2012-08-14

    Well established theory can be used to combine single-phenomenology hypothesis tests into a multi-phenomenology event screening hypothesis test (Fisher's and Tippett's tests). Commonly used standard error in Ms:mb event screening hypothesis test is not fully consistent with physical basis. Improved standard error - Better agreement with physical basis, and correctly partitions error to include Model Error as a component of variance, correctly reduces station noise variance through network averaging. For 2009 DPRK test - Commonly used standard error 'rejects' H0 even with better scaling slope ({beta} = 1, Selby et al.), improved standard error 'fails to rejects' H0.

  19. Patient Preferences Regarding Colorectal Cancer Screening: Test Features and Cost Willing to Pay Out of Pocket.

    Science.gov (United States)

    Moreno, Courtney C; Weiss, Paul S; Jarrett, Thomas L; Roberts, David L; Mittal, Pardeep K; Votaw, John R

    2016-01-01

    The purpose of this investigation was to evaluate whether test features would make an individual more or less likely to undergo colorectal cancer screening and how much an individual would be willing to pay out of pocket for a screening test. The methods include an administration of a survey to consecutive adult patients of a general medicine clinic. The survey consisted of Likert-scale questions assessing the patients' likelihood of choosing a screening test based on various test characteristics. Additional questions measured the patients' age, race, gender, and maximum out-of-pocket cost they would be willing to pay. Chi-square tests were used to assess the associations between the likelihood questions and the various demographic characteristics. In results, survey response rate was 88.8% (213 of 240). Respondents were 48.4% female (103 of 213), 51.6% male (110 of 213), 82.6% White (176 of 213), 11.3% African-American (24 of 213), and 6.1% other (13 of 213). Risk of internal injury and light exposure to radiation were the least desirable test features. Light sedation was the only test feature that most respondents (54.8%) indicated would make them likely or very likely to undergo a colorectal cancer screening test. The vast majority of respondents (86.8%) were willing to pay less than $200 out of pocket for a colorectal cancer screening test. There was no statistically significant difference in the responses of males and females, or in the responses of individuals of different races or different ages regarding test features, or the amount individuals were willing to pay for a screening test. To conclude, survey results suggest that patient education emphasizing the low complication rate of computed tomographic colonography (CTC), the minimal risks associated with the low-level radiation exposure resulting from CTC, and the benefits of a sedation-free test (eg, no risk of sedation-related complication and no need for a driver) may increase patient acceptance of

  20. Serodiagnosis of chronic Chagas infection by using EIE-Recombinant-Chagas-Biomanguinhos kit

    Directory of Open Access Journals (Sweden)

    Gomes Yara M

    2001-01-01

    Full Text Available A kit based on an enzyme immunoassay, EIE-Recombinant-Chagas-Biomanguinhos, developed by the Oswaldo Cruz Foundation, was evaluated for the serodiagnosis of chronic Chagas disease. Evaluation was performed with 368 serum samples collected from individuals living in an endemic area for Chagas disease: 131 patients in the chronic phase with confirmed clinical, epidemiological, and serological diagnosis (indirect immunofluorescence, indirect hemagglutination or enzyme-linked immunosorbent assay and 237 nonchagasic seronegative individuals were considered negative control. The EIE-Recombinant-Chagas-Biomanguinhos kit showed high sensitivity, 100% (CI 95%: 96.4-100% and high specificity, 100% (CI 95%: 98-100%. The data obtained were in full agreement with clinical and conventional serology data. In addition, no cross-reaction was observed with sera from patients with cutaneous (n=14 and visceral (n=3 leishmaniasis. However, when these sera were tested by conventional serological assays for Chagas disease, cross-reactions were detected in 14.3% and 33.3% of the patients with cutaneous and visceral leishmaniasis, respectively. No cross-reactions were observed when sera from nonchagasic seronegative patients bearing other infectious disease (syphilis, n=8; HTLV, n=8; HCV, n=7 and HBV, n=12 were tested. In addition, sera of patients with inconclusive results for Chagas disease by conventional serology showed results in agreement with clinical evaluation, when tested by the kit. These results are relevant and indicate that the refered kit provides a safe immunodiagnosis of Chagas disease and could be used in blood bank screening.

  1. The Internet Process Addiction Test: Screening for Addictions to Processes Facilitated by the Internet

    Directory of Open Access Journals (Sweden)

    Jason C. Northrup

    2015-07-01

    Full Text Available The Internet Process Addiction Test (IPAT was created to screen for potential addictive behaviors that could be facilitated by the internet. The IPAT was created with the mindset that the term “Internet addiction” is structurally problematic, as the Internet is simply the medium that one uses to access various addictive processes. The role of the internet in facilitating addictions, however, cannot be minimized. A new screening tool that effectively directed researchers and clinicians to the specific processes facilitated by the internet would therefore be useful. This study shows that the Internet Process Addiction Test (IPAT demonstrates good validity and reliability. Four addictive processes were effectively screened for with the IPAT: Online video game playing, online social networking, online sexual activity, and web surfing. Implications for further research and limitations of the study are discussed.

  2. The Internet Process Addiction Test: Screening for Addictions to Processes Facilitated by the Internet.

    Science.gov (United States)

    Northrup, Jason C; Lapierre, Coady; Kirk, Jeffrey; Rae, Cosette

    2015-07-28

    The Internet Process Addiction Test (IPAT) was created to screen for potential addictive behaviors that could be facilitated by the internet. The IPAT was created with the mindset that the term "Internet addiction" is structurally problematic, as the Internet is simply the medium that one uses to access various addictive processes. The role of the internet in facilitating addictions, however, cannot be minimized. A new screening tool that effectively directed researchers and clinicians to the specific processes facilitated by the internet would therefore be useful. This study shows that the Internet Process Addiction Test (IPAT) demonstrates good validity and reliability. Four addictive processes were effectively screened for with the IPAT: Online video game playing, online social networking, online sexual activity, and web surfing. Implications for further research and limitations of the study are discussed.

  3. Pathologic Stimulus Determines Lineage Commitment of Cardiac C-kit+ Cells.

    Science.gov (United States)

    Chen, Zhongming; Zhu, Wuqiang; Bender, Ingrid; Gong, Wuming; Kwak, Il-Youp; Yellamilli, Amritha; Hodges, Thomas J; Nemoto, Natsumi; Zhang, Jianyi; Garry, Daniel J; van Berlo, Jop H

    2017-12-12

    Although cardiac c-kit + cells are being tested in clinical trials, the circumstances that determine lineage differentiation of c-kit + cells in vivo are unknown. Recent findings suggest that endogenous cardiac c-kit + cells rarely contribute cardiomyocytes to the adult heart. We assessed whether various pathological stimuli differentially affect the eventual cell fates of c-kit + cells. We used single-cell sequencing and genetic lineage tracing of c-kit + cells to determine whether various pathological stimuli would result in different fates of c-kit + cells. Single-cell sequencing of cardiac CD45 - c-kit + cells showed innate heterogeneity, indicative of the existence of vascular and mesenchymal c-kit + cells in normal hearts. Cardiac pressure overload resulted in a modest increase in c-kit-derived cardiomyocytes, with significant increases in the numbers of endothelial cells and fibroblasts. Doxorubicin-induced acute cardiotoxicity did not increase c-kit-derived endothelial cell fates but instead induced cardiomyocyte differentiation. Mechanistically, doxorubicin-induced DNA damage in c-kit + cells resulted in expression of p53. Inhibition of p53 blocked cardiomyocyte differentiation in response to doxorubicin, whereas stabilization of p53 was sufficient to increase c-kit-derived cardiomyocyte differentiation. These results demonstrate that different pathological stimuli induce different cell fates of c-kit + cells in vivo. Although the overall rate of cardiomyocyte formation from c-kit + cells is still below clinically relevant levels, we show that p53 is central to the ability of c-kit + cells to adopt cardiomyocyte fates, which could lead to the development of strategies to preferentially generate cardiomyocytes from c-kit + cells. © 2017 American Heart Association, Inc.

  4. SUMA Technology and Newborn Screening Tests for Inherited Metabolic Diseases in Cuba

    Directory of Open Access Journals (Sweden)

    Ernesto Carlos González Reyes PhD

    2016-07-01

    Full Text Available The ultramicroanalytic system (SUMA, created in the 1980s, is a complete system of reagents and instrumentation to perform ultramicroassays combining the sensitivity of the micro-enzyme-linked immunosorbent assay (ELISA tests with the use of ultramicrovolumes. This technology permitted establishing large-scale newborn screening programs (NSPs for metabolic and endocrine disorders in Cuba. This article summarizes the main results of the implementation during the 30 years of SUMA technology in NSP for 5 inherited metabolic diseases, using ultramicroassays developed at the Department of Newborn Screening at the Immunoassay Center. Since 1986, SUMA technology has been used in the Cuban NSP for congenital hypothyroidism, initially studying thyroid hormone in cord serum samples. In 2000, a decentralized program for the detection of hyperphenylalaninemias using heel dried blood samples was initiated. These successful experiences permitted including protocols for screening congenital adrenal hyperplasia, galactosemia, and biotinidase deficiency in 2005. A program for the newborn screening of CH using the thyroid-stimulating hormone Neonatal ultramicro-ELISA was fully implemented in 2010. Nowadays, the NSP is supported by a network of 175 SUMA laboratories. After 30 years, more than 3.8 million Cuban newborns have been screened, and 1002 affected children have been detected. Moreover, SUMA technology has been presented in Latin America for over 2 decades and has contributed to screen around 17 million newborns. These results prove that developing countries can develop appropriate diagnostic technologies for making health care accessible to all.

  5. Validity of Commonly Used Clinical Tests to Diagnose and Screen for Spinal Pain in Adolescents

    DEFF Research Database (Denmark)

    Aartun, Ellen; Hartvigsen, Jan; Hestbaek, Lise

    2016-01-01

    , the area under the receiver operating characteristic curve ranged from 0.60 to 0.65. None of the selected tests could predict incidence cases of neck pain, mid back pain, or low back pain. CONCLUSION: Clinical tests commonly used in spinal screening in adolescents could not detect present spinal pain...... under the receiver operating characteristic curve was calculated for evaluation of all tests combined. RESULTS: The sensitivity was low, and specificity was high for all tests at both baseline (age, 11-13 years) and follow-up (age, 13-15 years). When all tests were evaluated collectively in 1 model...

  6. Self-Sampling for Human Papillomavirus Testing among Non-Attenders Increases Attendance to the Norwegian Cervical Cancer Screening Programme

    DEFF Research Database (Denmark)

    Enerly, Espen; Bonde, Jesper; Schee, Kristina

    2016-01-01

    Increasing attendance to screening offers the best potential for improving the effectiveness of well-established cervical cancer screening programs. Self-sampling at home for human papillomavirus (HPV) testing as an alternative to a clinical sampling can be a useful policy to increase attendance....... To determine whether self-sampling improves screening attendance for women who do not regularly attend the Norwegian Cervical Cancer Screening Programme (NCCSP), 800 women aged 25-69 years in the Oslo area who were due to receive a 2nd reminder to attend regular screening were randomly selected and invited...... alternative for increasing cervical cancer screening coverage in Norway....

  7. Screening test recommendations for methicillin-resistant Staphylococcus aureus surveillance practices: A cost-minimization analysis.

    Science.gov (United States)

    Whittington, Melanie D; Curtis, Donna J; Atherly, Adam J; Bradley, Cathy J; Lindrooth, Richard C; Campbell, Jonathan D

    2017-07-01

    To mitigate methicillin-resistant Staphylococcus aureus (MRSA) infections, intensive care units (ICUs) conduct surveillance through screening patients upon admission followed by adhering to isolation precautions. Two surveillance approaches commonly implemented are universal preemptive isolation and targeted isolation of only MRSA-positive patients. Decision analysis was used to calculate the total cost of universal preemptive isolation and targeted isolation. The screening test used as part of the surveillance practice was varied to identify which screening test minimized inappropriate and total costs. A probabilistic sensitivity analysis was conducted to evaluate the range of total costs resulting from variation in inputs. The total cost of the universal preemptive isolation surveillance practice was minimized when a polymerase chain reaction screening test was used ($82.51 per patient). Costs were $207.60 more per patient when a conventional culture was used due to the longer turnaround time and thus higher isolation costs. The total cost of the targeted isolation surveillance practice was minimized when chromogenic agar 24-hour testing was used ($8.54 per patient). Costs were $22.41 more per patient when polymerase chain reaction was used. For ICUs that preemptively isolate all patients, the use of a polymerase chain reaction screening test is recommended because it can minimize total costs by reducing inappropriate isolation costs. For ICUs that only isolate MRSA-positive patients, the use of chromogenic agar 24-hour testing is recommended to minimize total costs. Copyright © 2017 Association for Professionals in Infection Control and Epidemiology, Inc. Published by Elsevier Inc. All rights reserved.

  8. Implementation of laser speckle contrast analysis as connection kit for mobile phone for assessment of skin blood flow

    Science.gov (United States)

    Jakovels, Dainis; Saknite, Inga; Spigulis, Janis

    2014-05-01

    Laser speckle contrast analysis (LASCA) offers a non-contact, full-field, and real-time mapping of capillary blood flow and can be considered as an alternative method to Laser Doppler perfusion imaging. LASCA technique has been implemented in several commercial instruments. However, these systems are still too expensive and bulky to be widely available. Several optical techniques have found new implementations as connection kits for mobile phones thus offering low cost screening devices. In this work we demonstrate simple implementation of LASCA imaging technique as connection kit for mobile phone for primary low-cost assessment of skin blood flow. Stabilized 650 nm and 532 nm laser diode modules were used for LASCA illumination. Dual wavelength illumination could provide additional information about skin hemoglobin and oxygenation level. The proposed approach was tested for arterial occlusion and heat test. Besides, blood flow maps of injured and provoked skin were demonstrated.

  9. Can the Bruckner test be used as a rapid screening test to detect significant refractive errors in children?

    Directory of Open Access Journals (Sweden)

    Kothari Mihir

    2007-01-01

    Full Text Available Purpose: To assess the suitability of Brückner test as a screening test to detect significant refractive errors in children. Materials and Methods: A pediatric ophthalmologist prospectively observed the size and location of pupillary crescent on Brückner test as hyperopic, myopic or astigmatic. This was compared with the cycloplegic refraction. Detailed ophthalmic examination was done for all. Sensitivity, specificity, positive predictive value and negative predictive value of Brückner test were determined for the defined cutoff levels of ametropia. Results: Ninety-six subjects were examined. Mean age was 8.6 years (range 1 to 16 years. Brückner test could be completed for all; the time taken to complete this test was 10 seconds per subject. The ophthalmologist identified 131 eyes as ametropic, 61 as emmetropic. The Brückner test had sensitivity 91%, specificity 72.8%, positive predictive value 85.5% and negative predictive value 83.6%. Of 10 false negatives four had compound hypermetropic astigmatism and three had myopia. Conclusions: Brückner test can be used to rapidly screen the children for significant refractive errors. The potential benefits from such use may be maximized if programs use the test with lower crescent measurement cutoffs, a crescent measurement ruler and a distance fixation target.

  10. Influence of test reliability on the screening performance of frequency-doubling perimetry

    NARCIS (Netherlands)

    Heeg, GP; Jansonius, NM

    PURPOSE: To investigate the influence of test reliability on the screening performance of frequency,doubling perimetry (FDT). DESIGN: Cross-sectional study. METHODS: FDT sensitivity and specificity were calculated three times using three different strategies for handling unreliable (that is, > 0

  11. Individual differences in aversion to ambiguity regarding medical tests and treatments: association with cancer screening cognitions.

    Science.gov (United States)

    Han, Paul K J; Williams, Andrew E; Haskins, Amy; Gutheil, Caitlin; Lucas, F Lee; Klein, William M P; Mazor, Kathleen M

    2014-12-01

    Aversion to "ambiguity"-uncertainty about the reliability, credibility, or adequacy of information-about medical tests and treatments is an important psychological response that varies among individuals, but little is known about its nature and extent. The purpose of this study was to examine how individual-level ambiguity aversion relates to important health cognitions related to different cancer screening tests. A survey of 1,074 adults, ages 40 to 70 years, was conducted in four integrated U.S. healthcare systems. The Ambiguity Aversion in Medicine (AA-Med) scale, a measure of individual differences in aversion to ambiguity (AA) about medical tests and treatments, was administered along with measures of several cancer screening-related cognitions: perceived benefits and harms of colonoscopy, mammography, and PSA screening, and ambivalence and future intentions regarding these tests. Multivariable analyses were conducted to assess the associations between AA-Med scores and cancer screening cognitions. Individual-level AA as assessed by the AA-Med scale was significantly associated (P ambiguity. Individual-level AA constitutes a measurable, wide-ranging cognitive bias against medical intervention, and more research is needed to elucidate its mechanisms and effects. ©2014 American Association for Cancer Research.

  12. Participation behaviour following a false positive test in the Copenhagen mammography screening programme

    DEFF Research Database (Denmark)

    Andersen, Sune Bangsbøll; Vejborg, Ilse; von Euler-Chelpin, My

    2008-01-01

    women experiencing a negative screening test, regardless of whether the false positive statement was given following assessment or following surgery. The benign to malignant biopsy ratio, comparing the type B false positives to the true positives, was by the fifth round well below the desirable level...

  13. Noninvasiv prænatal test er et gennembrud inden for prænatal screening

    DEFF Research Database (Denmark)

    Hornstrup, Louise Stig; Ambye, Louise; Sørensen, Steen

    2015-01-01

    Non-invasive prenatal testing (NIPT) using cell-free fetal DNA from the peripheral blood of the pregnant woman has become a possibility within recent years, but is not yet implemented in Denmark. NIPT has proven to be very efficient in the screening for especially trisomi 21. This article...

  14. Screening of Plant Extracts for Antioxidant Activity: a Comparative Study on Three Testing Methods

    NARCIS (Netherlands)

    Koleva, I.; Beek, van T.A.; Linssen, J.P.H.; Groot, de Æ.; Evstatieva, L.N.

    2002-01-01

    Three methods widely employed in the evaluation of antioxidant activity, namely 2,2-diphenyl-1-picrylhydrazyl (DPPH) radical scavenging method, static headspace gas chromatography (HS-GC) and -carotene bleaching test (BCBT), have been compared with regard to their application in the screening of

  15. Concordant testing results between various Human Papillomavirus assays in primary cervical cancer screening

    DEFF Research Database (Denmark)

    de Thurah, Lena; Bonde, Jesper; Hoa Lam, Janni Uyen

    2018-01-01

    OBJECTIVES: Human Papillomavirus (HPV) assays are increasingly used for primary cervical screening and HPV vaccination effect monitoring. We undertook a systematic literature review to determine the concordance in positive test results (i.e., detection of HPV infections) between Hybrid Capture 2 ...

  16. Contribution to the study for an optimum choice of filter and screens in radiographic testing

    International Nuclear Information System (INIS)

    Caillieret, V.; Peix, G.; Babot, D.; Lormand, G.

    1985-01-01

    In order to optimize the choices of screens and filter in steel specimens radiographic testing with iridium 192 and cobalt 60, we started a theoretical and experimental study of their actions on radiative and latent images formation. Theoretical modelisation of photons interactions in steel and experimental apparatus for spectral analysis are described

  17. Screening for congenital toxoplasmosis: accuracy of immunoglobulin M and immunoglobulin A tests after birth

    DEFF Research Database (Denmark)

    Gilbert, Ruth E; Thalib, Lukman; Tan, Hooi Kuan

    2007-01-01

    OBJECTIVES: To determine the accuracy of postnatal screening for toxoplasma-specific immunoglobulin (Ig) M and IgA. SETTING: Ten centres in three European countries. METHODS: We compared results of the first postnatal IgM or IgA test in infants with infected mothers identified by prenatal screeni...

  18. Spectrum of patients with hypermethioninemia based on neonatal screening tests over 14 years

    Directory of Open Access Journals (Sweden)

    Se Jung Oh

    2010-03-01

    Full Text Available Purpose : The neonatal screening test for homocystinuria primarily measures methionine by using a dried blood specimen. We investigated the incidence and clinical manifestations of homocystinuria, isolated hypermethioninemia, and transient hypermethioninemia among patients with hypermethioninemia on a neonatal screening test. Methods : We performed a retrospective study of 58 patients transferred to Shoonchunhyang Hospital because of hypermethioninemia on a neonatal screening test between January 1996 and August 2009. We analyzed the level of amino acid from plasma and urine, as well as blood homocysteine. Results : Almost half of the 58 patients were identified as normal. Whereas only 3 (5.1% patients were identified as having homocystinuria, about 20.7% (12 cases of the patients had isolated hypermethioninemia. The ages of these two groups at initial detection of hypermethioninemia on plasma amino acid analysis were 50.0¡?#?2.5; days and 34.9¡?#?3.5; days, respectively. Both groups were put on diets, and they showed a normal developmental course as a result of early diagnosis and treatment. Conclusion : Hypermethioninemia without homocystinuria, referred to as isolated hypermethioninemia, was also detected. Thus, the impact of hypermethioninemia on a neonatal screening test should be carefully evaluated through analysis of amino acid levels from blood and urine, and we need to detect and treat an early stage of isolated hypermethioninemia as well as homocystinuria.

  19. Evaluation of a Screening Test for Female College Athletes with Eating Disorders and Disordered Eating

    Science.gov (United States)

    Nagel, Deborah L.; Black, David R.; Leverenz, Larry J.; Coster, Daniel C.

    2000-01-01

    Objective: To develop a screening test to detect female college athletes with eating disorders/disordered eating (ED/ DE). No validated eating disorder screening tests specifically for athletes have been available. Design and Setting: In this cross-sectional study, subjects from a large midwestern university completed 3 objective tests and a structured diagnostic interview. Measurements: A new test, developed and pilot tested by the researchers (Athletic Milieu Direct Questionnaire, AMDQ), and 2 tests normed for the general population (Eating Disorder Inventory-2, Bulimia Test-Revised) were used to identify ED/DE athletes. A structured, validated, diagnostic interview (Eating Disorder Examination, version 12.OD) was used to determine which test was most effective in screening female college athletes. Subjects: Subjects included 149 female athletes, ages 18 to 25 years, from 11 Division I and select club sports. Results: ED/DE subjects (35%) were found in almost every sport. Of the ED/DE subjects, 65% exhibited disordered eating, 25% were bulimic, 8% were classified as eating disordered not otherwise specified (NOS), and 2% were anorexic. The AMDQ more accurately identified ED/DE than any test or combination of items. The AMDQ produced superior results on 7 of 9 epidemiologic analyses; sensitivity was 80% and specificity was 77%, meaning that it correctly classified approximately 4 of every 5 persons who were truly exhibiting an eating disorder or disordered eating. Conclusions: We recommend that the AMDQ subsets, which met statistical criteria, be used to screen for ED/DE to enable early identification of athletes at the disordered eating or NOS stage and to initiate interventions before the disorder progresses. PMID:16558658

  20. Interpretation of Errors Made by Mandarin-Speaking Children on the Preschool Language Scales--5th Edition Screening Test

    Science.gov (United States)

    Ren, Yonggang; Rattanasone, Nan Xu; Wyver, Shirley; Hinton, Amber; Demuth, Katherine

    2016-01-01

    We investigated typical errors made by Mandarin-speaking children when measured by the Preschool Language Scales-fifth edition, Screening Test (PLS-5 Screening Test). The intention was to provide preliminary data for the development of a guideline for early childhood educators and psychologists who use the test with Mandarin-speaking children.…

  1. Testing for direct genetic effects using a screening step in family-based association studies

    Directory of Open Access Journals (Sweden)

    Sharon M Lutz

    2013-11-01

    Full Text Available In genome wide association studies (GWAS, families based studies tend to have less power to detect genetic associations than population based studies, such as case-control studies. This can be an issue when testing if genes in a family based GWAS have a direct effect on the phenotype of interest or if the genes act indirectly through a secondary phenotype. When multiple SNPs are tested for a direct effect in the family based study, a screening step can be used to minimize the burden of multiple comparisons in the causal analysis. We propose a 2-stage screening step that can be incorporated into the family based association test (FBAT approach similar to the conditional mean model approach in the VanSteen-algorithm [1]. Simulations demonstrate that the type 1 error is preserved and this method is advantageous when multiple markers are tested. This method is illustrated by an application to the Framingham Heart Study.

  2. Evaluation of Calypte AWARE HIV-1/2 OMT antibody test as a screening test in an Indian setting

    Directory of Open Access Journals (Sweden)

    Ingole N

    2010-01-01

    Full Text Available Purpose: Integrated counselling and testing centres (ICTC provide counselling and blood testing facilities for HIV diagnosis. Oral fluid tests provide an alternative for people whodo not want blood to be drawn. Also, it avoids the risk of occupational exposure. The goal of this study was to evaluate the utility of Calypte AWARE HIV-1/2 OMT antibody test as a screening test in an Indian setting. Materials and Methods: A cross-sectional study was carried out after ethics committee approval in 250 adult ICTC clients. Blood was collected and tested from these clients for HIV diagnosis as per routine policy and the results were considered as the gold standard. Also, after another written informed consent, oral fluid was collected from the clients and tested for the presence of HIV antibodies. Twenty five clients who had and 25 clients who had not completed their secondary school education (Group A and Group B, respectively were also asked to perform and interpret the test on their own and their findings and experiences were noted. Result: The sensitivity, specificity, PPV and NPV of the oral fluid antibody test were 100%, 98.51%, 94.11% and 100%, respectively. Seventy six percent of clients preferred oral fluid testing. Group B found it difficult to perform the test as compared to Group A and this difference was statistically significant (P ≤ 0.05. Conclusion: Oral fluid testing can be used as a screening test for HIV diagnosis; however, confirmation of reactive results by blood-based tests is a must.

  3. Awareness and uptake of colorectal, breast, cervical and prostate cancer screening tests in Spain.

    Science.gov (United States)

    Carrasco-Garrido, Pilar; Hernandez-Barrera, Valentın; Lopez de Andres, Ana; Jimenez-Trujillo, Isabel; Gallardo Pino, Carmen; Jimenez-Garcıa, Rodrigo

    2014-04-01

    We aim to describe levels of awareness and uptake of colorectal, breast, cervical and prostate cancer screening tests and to analyze the association to socio-demographic and health-related variables. Population-based cross-sectional study conducted using a home-based personal interview survey on a nationwide representative sample (n = 7938) of population aged ≥18 years (Oncobarometro Survey). Awareness was assessed by asking participants: Now I am going to mention several medical tests for cancer detection, please tell me if you already know about them or if this is the first time you have heard of them? The tests mentioned were faecal occult blood test (FOBT), mammography, Pap smear and prostate-specific antigen (PSA). Cancer screening uptake was assessed by asking participants whether they had received tests within the previous 2 years. Awareness rates of 38.55% for FOBT, 95.03% for mammography, 70.84% for Pap smears and 54.72% for PSA were found. Uptake mammography was 74.46%, Pap smears 65.57%, PSA 35.19% and FOBT 9.40%. Factors such as immigration status, lower educational level or income and not suffering from chronic conditions are negative predictors for uptake. Awareness and uptake results showed acceptable figures for mammography, moderate for Pap smears and unacceptably low for FOBT. Inequalities exist in uptake of cancer screening. It is necessary to develop public health educational programmes, especially for the vulnerable populations, aiming to inform and motivate them to use screening services on a regular basis. Our data suggest that although PSA is not recommended, this opportunistic screening is frequently used in Spain.

  4. Evaluation of the HISCL Anti-Treponema pallidum Assay as a Screening Test for Syphilis

    OpenAIRE

    An, Jingna; Chen, Qixia; Liu, Qianqian; Rao, Chenli; Li, Dongdong; Wang, Tingting; Tao, Chuanmin; Wang, Lanlan

    2015-01-01

    The resurgence of syphilis in recent years has become a serious threat to public health worldwide, and the serological detection of specific antibodies against Treponema pallidum remains the most reliable method for laboratory diagnosis of syphilis. This study examined the performance of the recently launched HISCL anti-Treponema pallidum (anti-TP) assay as a screening test for syphilis in a high-volume laboratory. The HISCL anti-TP assay was tested in 300 preselected syphilis-positive sample...

  5. Application of direct agglutination test (DAT) and fast agglutination screening test (FAST) for sero-diagnosis of visceral leishmaniasis in endemic area of Minas Gerais, Brazil

    NARCIS (Netherlands)

    Silva, Eduardo S.; Schoone, Gerard J.; Gontijo, Celia M. F.; Brazil, Reginaldo P.; Pacheco, Raquel S.; Schallig, Henk D. F. H.

    2005-01-01

    The direct agglutination test (DAT) has proved to be a very important sero-diagnostic tool combining high levels of intrinsic validity and ease of performance. Otherwise, fast agglutination screening test (FAST) utilises only one serum dilution making the test very suitable for the screening of

  6. Correlation Between Screening Mammography Interpretive Performance on a Test Set and Performance in Clinical Practice.

    Science.gov (United States)

    Miglioretti, Diana L; Ichikawa, Laura; Smith, Robert A; Buist, Diana S M; Carney, Patricia A; Geller, Berta; Monsees, Barbara; Onega, Tracy; Rosenberg, Robert; Sickles, Edward A; Yankaskas, Bonnie C; Kerlikowske, Karla

    2017-10-01

    Evidence is inconsistent about whether radiologists' interpretive performance on a screening mammography test set reflects their performance in clinical practice. This study aimed to estimate the correlation between test set and clinical performance and determine if the correlation is influenced by cancer prevalence or lesion difficulty in the test set. This institutional review board-approved study randomized 83 radiologists from six Breast Cancer Surveillance Consortium registries to assess one of four test sets of 109 screening mammograms each; 48 radiologists completed a fifth test set of 110 mammograms 2 years later. Test sets differed in number of cancer cases and difficulty of lesion detection. Test set sensitivity and specificity were estimated using woman-level and breast-level recall with cancer status and expert opinion as gold standards. Clinical performance was estimated using women-level recall with cancer status as the gold standard. Spearman rank correlations between test set and clinical performance with 95% confidence intervals (CI) were estimated. For test sets with fewer cancers (N = 15) that were more difficult to detect, correlations were weak to moderate for sensitivity (woman level = 0.46, 95% CI = 0.16, 0.69; breast level = 0.35, 95% CI = 0.03, 0.61) and weak for specificity (0.24, 95% CI = 0.01, 0.45) relative to expert recall. Correlations for test sets with more cancers (N = 30) were close to 0 and not statistically significant. Correlations between screening performance on a test set and performance in clinical practice are not strong. Test set performance more accurately reflects performance in clinical practice if cancer prevalence is low and lesions are challenging to detect. Copyright © 2017 The Association of University Radiologists. Published by Elsevier Inc. All rights reserved.

  7. Determination of triiodothyronine using RIA-Mat T3 kit

    International Nuclear Information System (INIS)

    Hara, Masao

    1975-01-01

    A RIA-Mat T 3 kit was used for an in vitro measurement of triiodothyronine in serum. A resin strip was utilized to absorb free triiodothyronine after the serum was incubated with antibody against triiodothyronine. This test was easy to manipulate and the reproducibility test with same sera, dilution test, and recovery test were also satisfactory. The normal range of triiodothyronine determined with this test kit was 119 +- 40 ng/dl using 50 test sera. Ninety sera with various thyroid diseases were also determined. (auth.)

  8. The use of the osmole gap as a screening test for the presence of exogenous substances.

    Science.gov (United States)

    Purssell, Roy A; Lynd, Larry D; Koga, Yoshikata

    2004-01-01

    The rapid and accurate diagnosis of toxic alcohol poisoning due to methanol (methyl alcohol) [MeOH] and ethylene glycol (EG), is paramount in preventing serious adverse outcomes. The quantitative measurement of specific serum levels of these substances using gas chromatography is expensive, time consuming and generally only available at major tertiary-care facilities. Therefore, because these toxic substances are osmotically active and the measurement of serum osmolality is easily performed and more readily available, the presence of an osmole gap (OG) has been adopted as an alternative screening test. By definition, the OG is the difference between the measured serum osmolality determined using the freezing point depression (Osm(m)) and the calculated serum molarity (Mc), which is estimated from the known and readily measurable osmotically active substances in the serum, in particular sodium, urea, glucose, and potassium and ethanol (alcohol). Thus, the OG=Osm(m)-Mc, and an OG above a specific threshold (the threshold of positivity) suggests the presence of unmeasured osmotically active substances, which could be indicative of a toxic exposure. The objectives of this study were to review the principles of evaluating screening tests, the theory behind the OG as a screening test and the literature upon which the adoption of the OG as a screening test has been based. This review revealed that there have been numerous equations derived and proposed for the estimation of the Mc, with the objective of developing empirical evidence of the best equation for the determination of the OG and ultimately the utility of OG as a screening test. However, the methods and statistical analysis employed have generally been inconsistent with recommended guidelines for screening test evaluation and although many equations have been derived, they have not been appropriately validated. Specific evidence of the clinical utility of the OG requires that a threshold of positivity be

  9. Uptake of a colorectal cancer screening blood test in people with elevated risk for cancer who cannot or will not complete a faecal occult blood test.

    Science.gov (United States)

    Symonds, Erin L; Cock, Charles; Meng, Rosie; Cole, Stephen R; Fraser, Robert J L; Young, Graeme P

    2017-03-31

    Participation rates in colorectal cancer (CRC) screening programmes using faecal occult blood tests (FOBTs) are low. Nonparticipation is commonly attributed to psychosocial factors, but some medical conditions also prevent screening. These barriers might be partially overcome if a blood test for CRC screening was available. This study determined whether people who had always declined screening by FOBT would participate if offered a blood test. An audit of registrants within a personalized CRC screening programme was undertaken to determine the reasons for regular nonparticipation in FOBT. Consistent nonparticipants (n=240) were randomly selected and invited for CRC screening with a blood test. Demographic characteristics and the reasons for prior FOBT nonparticipation were collected by means of a questionnaire. Nonparticipation in the screening programme could be classified as either behavioural (8.6%), with consistent noncompliance, or due to medical contraindications (8.5%), which included chronic rectal bleeding, being deemed unsuitable by a health professional, and needing personal assistance. Blood test uptake was 25%, with participation in the medical contraindications group greater than that in the behavioural group (43 vs. 12%, Pprocrastination and dislike of the test, but these were not associated with blood test uptake (P>0.05). There is a subgroup of the community who have medical reasons for nonparticipation in CRC screening with FOBT but will participate if offered a blood test. The option of a blood test does not, however, improve uptake in those who admit to behavioural reasons for noncompliance with screening.

  10. Energy Management Curriculum Starter Kit

    Energy Technology Data Exchange (ETDEWEB)

    Turner, W.C.

    1987-02-01

    The Energy Management Curriculum Starter Kit was designed to help engineering educators develop and teach energy management courses. Montana State University and Oklahoma State University courses are embodied in the model curriculum given. The curricula offered at many other universities throughout the United States are also presented. The kit was designed specifically to train engineering students to be good energy managers. Courses at both the undergraduate and postgraduate level are presented.

  11. RBC Antibody Screen

    Science.gov (United States)

    ... C Cystic Fibrosis (CF) Gene Mutations Testing Cytomegalovirus (CMV) Tests D-dimer Dengue Fever Testing Des-gamma- ... Index of Screening Recommendations Not Listed? Not Listed? Newborn Screening Screening Tests for Infants Screening Tests for ...

  12. Environmental Technology Verification Report for Abraxis Ecologenia® 17β-Estradiol (E2) Microplate Enzyme-Linked Immunosorbent Assay (ELISA) Test Kits

    Science.gov (United States)

    This verification test was conducted according to procedures specifiedin the Test/QA Planfor Verification of Enzyme-Linked Immunosorbent Assay (ELISA) Test Kis for the Quantitative Determination of Endocrine Disrupting Compounds (EDCs) in Aqueous Phase Samples. Deviations to the...

  13. One window-period donation in two years of individual donor-nucleic acid test screening for hepatitis B, hepatitis C and human immunodeficiency virus

    Directory of Open Access Journals (Sweden)

    Jose Eduardo Levi

    2013-06-01

    Full Text Available Objective: To describe general data on nucleic acid/serology testing and report the first hepatitis B-nucleic acid testing yield case of an immunized donor in Brazil. Methods: A total of 24,441 donations collected in 2010 and 2011 were submitted to individual nucleic acid testing for hepatitis B, hepatitis C and human immunodeficiency virus using the TaqMan® MPX kit (Roche on the Cobas s201 platform, in addition to routine screening for serological markers. Nucleic acid testing-reactive donations were further evaluated by real-time polymerase chain reaction using Cobas AmpliPrep/Cobas TaqMan hepatitis B virus, hepatitis C virus and human immunodeficiency virus tests. Results: Thirty-two donations were reactive by nucleic acid testing, 31 were also serologically reactive and one first-time donor was identified as having hepatitis B in the window period. Follow-up samples showed increasing titers of anti-HBs rising from 19 UI/mL in the index donation to 109 IU/mL seven months later attributable to his vaccination history. Curiously, this donor was never reactive for HbsAg nor for anti-HBc. In the yield donation, he was concomitantly reactive for syphilis (enzyme immunoassay and fluorescent treponemal antibody-absorption; venereal disease research laboratory non-reactive. Overall, six donors (0.02% were characterized as occult hepatitis B. A total of 35% of the confirmed (recombinant immunoblot assay positive hepatitis C donations were nucleic acid testing non-reactive and no human immunodeficiency virus "elite controller" was identified. Conclusion: The yield rate (1:24,441; 95% confidence interval: 1:9,537 - 1:89,717 contrasts to the North American rate (1:410,540 donations and strongly advocates the adoption of nucleic acid testing for hepatitis B in Brazil despite the increasing rate of anti-HBs reactive subjects due to the successful immunization program.

  14. A score based on screening tests to differentiate mild cognitive impairment from subjective memory complaints

    Directory of Open Access Journals (Sweden)

    Fábio Henrique de Gobbi Porto

    2013-09-01

    Full Text Available It is not easy to differentiate patients with mild cognitive impairment (MCI from subjective memory complainers (SMC. Assessments with screening cognitive tools are essential, particularly in primary care where most patients are seen. The objective of this study was to evaluate the diagnostic accuracy of screening cognitive tests and to propose a score derived from screening tests. Elderly subjects with memory complaints were evaluated using the Mini Mental State Examination (MMSE and the Brief Cognitive Battery (BCB. We added two delayed recalls in the MMSE (a delayed recall and a late-delayed recall, LDR, and also a phonemic fluency test of letter P fluency (LPF. A score was created based on these tests. The diagnoses were made on the basis of clinical consensus and neuropsychological testing. Receiver operating characteristic curve analyses were used to determine area under the curve (AUC, the sensitivity and specificity for each test separately and for the final proposed score. MMSE, LDR, LPF and delayed recall of BCB scores reach statistically significant differences between groups (P=0.000, 0.03, 0.001 and 0.01, respectively. Sensitivity, specificity and AUC were MMSE: 64%, 79% and 0.75 (cut off <29; LDR: 56%, 62% and 0.62 (cut off <3; LPF: 71%, 71% and 0.71 (cut off <14; delayed recall of BCB: 56%, 82% and 0.68 (cut off <9. The proposed score reached a sensitivity of 88% and 76% and specificity of 62% and 75% for cut off over 1 and over 2, respectively. AUC were 0.81. In conclusion, a score created from screening tests is capable of discriminating MCI from SMC with moderate to good accurancy.

  15. The Clock Drawing Test versus Mini-mental Status Examination as a Screening Tool for Dementia: A Clinical Comparison

    Science.gov (United States)

    Palsetia, Delnaz; Rao, G. Prasad; Tiwari, Sarvada C.; Lodha, Pragya; De Sousa, Avinash

    2018-01-01

    There is a growing incidence of dementia patients in the community, and with this growth, there is need for rapid, valid, and easily administrable tests for the screening of dementia and mild cognitive impairment in the community. This review looks at the two most commonly used tests in dementia screening, namely, the clock drawing test (CDT) and the mini-mental status examination (MMSE). Both these tests have been used in dementia screening over the past three decades and have been the subject of scrutiny of various studies, reviews, and meta-analysis. Both these tests are analyzed on their ability to assess dementia and screen for it in the community, general practice and general hospital settings. The methods of administration and scoring of each test are discussed, and their advantages and disadvantages are explained. There is also a direct comparison made between the MMSE and CDT in dementia screening. Future research needs with these tests are also elucidated. PMID:29403122

  16. The Clock Drawing Test versus Mini-mental Status Examination as a Screening Tool for Dementia: A Clinical Comparison.

    Science.gov (United States)

    Palsetia, Delnaz; Rao, G Prasad; Tiwari, Sarvada C; Lodha, Pragya; De Sousa, Avinash

    2018-01-01

    There is a growing incidence of dementia patients in the community, and with this growth, there is need for rapid, valid, and easily administrable tests for the screening of dementia and mild cognitive impairment in the community. This review looks at the two most commonly used tests in dementia screening, namely, the clock drawing test (CDT) and the mini-mental status examination (MMSE). Both these tests have been used in dementia screening over the past three decades and have been the subject of scrutiny of various studies, reviews, and meta-analysis. Both these tests are analyzed on their ability to assess dementia and screen for it in the community, general practice and general hospital settings. The methods of administration and scoring of each test are discussed, and their advantages and disadvantages are explained. There is also a direct comparison made between the MMSE and CDT in dementia screening. Future research needs with these tests are also elucidated.

  17. Method for screening the Nevada Test Site and contiguous areas for nuclear waste repository locations

    International Nuclear Information System (INIS)

    Sinnock, S.; Fernandez, J.A.; Neal, J.T.; Stephens, H.P.; Hartway, B.L.; Los Alamos Technical Associates, Inc., NM)

    1982-01-01

    This paper outlines the general concepts of a technical method for systematic screening of the Nevada Test Site (NTS), Nye County, Nevada, for potentially suitable nuclear waste repository locations. After a general discussion of the organization and the purpose of the current screening activity, the paper addresses the steps of the screening method. These steps include: hierarchically organizing technical objectives for repository performance (an objectives tree); identifying and mapping pertinent physical characteristics of a site and its setting (physical attributes); relating the physical conditions to the objectives (favorability curves); identifying alternative locations and numerically evaluating their relative merits; investigating the effects of subjective judgments on the evaluations (sensitivity analyses); documenting the assumptions, logic, and results of the method. 19 references, 10 figures

  18. Smartphone-based audiometric test for screening hearing loss in the elderly.

    Science.gov (United States)

    Abu-Ghanem, Sara; Handzel, Ophir; Ness, Lior; Ben-Artzi-Blima, Miri; Fait-Ghelbendorf, Karin; Himmelfarb, Mordechai

    2016-02-01

    Hearing loss is widespread among the elderly. One of the main obstacles to rehabilitation is identifying individuals with potentially correctable hearing loss. Smartphone-based hearing tests can be administered at home, thus greatly facilitating access to screening. This study evaluates the use of a smartphone application as a screening tool for hearing loss in individuals aged ≥ 65 years. Twenty-six subjects aged 84.4 ± 6.73 years (mean ± SD) were recruited. Pure-tone audiometry was administered by both a smartphone application (uHear for iPhone, v1.0 Unitron, Canada) and a standard portable audiometer by trained personnel. Participants also completed a questionnaire on their hearing. Pure-tone thresholds were compared between the two testing modalities and correlated with the questionnaire results. The cutoff point for failing screening tests was a pure tone average of 40 dB for the frequencies 250-6,000 Hz. The smartphone application's pure tone thresholds were higher (poorer hearing) than the audiometric thresholds, with a significant difference in all frequencies but 2,000 Hz. The application and the audiometric values were in agreement for 24 subjects (92 %). The application had a sensitivity of 100 % and specificity of 60 % for screening compared with the audiometer. The questionnaire was significantly less accurate, having assigned a passing score to three participants who failed both the application and audiometric tests. While a smartphone application may not be able to accurately determine the level of hearing impairment, it is useful as a highly accessible portable audiometer substitute for screening for hearing loss in elderly populations.

  19. Primary care validation of a single-question alcohol screening test.

    Science.gov (United States)

    Smith, Peter C; Schmidt, Susan M; Allensworth-Davies, Donald; Saitz, Richard

    2009-07-01

    Unhealthy alcohol use is prevalent but under-diagnosed in primary care settings. To validate, in primary care, a single-item screening test for unhealthy alcohol use recommended by the National Institute on Alcohol Abuse and Alcoholism (NIAAA). Cross-sectional study. Adult English-speaking patients recruited from primary care waiting rooms. Participants were asked the single screening question, “How many times in the past year have you had X or more drinks in a day?”, where X is 5 for men and 4 for women, and a response of 1 or greater [corrected] is considered positive. Unhealthy alcohol use was defined as the presence of an alcohol use disorder, as determined by a standardized diagnostic interview, or risky consumption, as determined using a validated 30-day calendar method. Of 394 eligible primary care patients, 286 (73%) completed the interview. The single-question screen was 81.8% sensitive (95% confidence interval (CI) 72.5% to 88.5%) and 79.3% specific (95% CI 73.1% to 84.4%) for the detection of unhealthy alcohol use. It was slightly more sensitive (87.9%, 95% CI 72.7% to 95.2%) but was less specific (66.8%, 95% CI 60.8% to 72.3%) for the detection of a current alcohol use disorder. Test characteristics were similar to that of a commonly used three-item screen, and were affected very little by subject demographic characteristics. The single screening question recommended by the NIAAA accurately identified unhealthy alcohol use in this sample of primary care patients. These findings support the use of this brief screen in primary care.

  20. Testing the reliability of the Fall Risk Screening Tool in an elderly ambulatory population.

    Science.gov (United States)

    Fielding, Susan J; McKay, Michael; Hyrkas, Kristiina

    2013-11-01

    To identify and test the reliability of a fall risk screening tool in an ambulatory outpatient clinic. The Fall Risk Screening Tool (Albert Lea Medical Center, MN, USA) was scripted for an interview format. Two interviewers separately screened a convenience sample of 111 patients (age ≥ 65 years) in an ambulatory outpatient clinic in a northeastern US city. The interviewers' scoring of fall risk categories was similar. There was good internal consistency (Cronbach's α = 0.834-0.889) and inter-rater reliability [intra-class correlation coefficients (ICC) = 0.824-0.881] for total, Risk Factor and Client's Health Status subscales. The Physical Environment scores indicated acceptable internal consistency (Cronbach's α = 0.742) and adequate reliability (ICC = 0.688). Two Physical Environment items (furniture and medical equipment condition) had low reliabilities [Kappa (K) = 0.323, P = 0.08; K = -0.078, P = 0.648), respectively. The scripted Fall Risk Screening Tool demonstrated good reliability in this sample. Rewording two Physical Environment items will be considered. A reliable instrument such as the scripted Fall Risk Screening Tool provides a standardised assessment for identifying high fall risk patients. This tool is especially useful because it assesses personal, behavioural and environmental factors specific to community-dwelling patients; the interview format also facilitates patient-provider interaction. © 2013 John Wiley & Sons Ltd.

  1. Forward Genetic Screening Using Behavioral Tests in Zebrafish: A Proof of Concept Analysis of Mutants.

    Science.gov (United States)

    Gerlai, Robert; Poshusta, Tanya L; Rampersad, Mindy; Fernandes, Yohaan; Greenwood, Tammy M; Cousin, Margot A; Klee, Eric W; Clark, Karl J

    2017-01-01

    The zebrafish enjoys several advantages over other model organisms. It is small, easy to maintain, prolific, and numerous genetic tools are available for it. For example, forward genetic screens have allowed investigators to identify important genes potentially involved in a variety of functions from embryogenesis to cancer. However, despite its sophisticated behavioral repertoire, behavioral methods have rarely been utilized in forward genetic screens. Here, we employ a two-tiered strategy, a proof of concept study, to explore the feasibility of behavioral screens. We generated mutant lines using transposon-based insertional mutagenesis, allowing us to bias mutant selection with target genes expressed within the brain. Furthermore, we employed an efficient and fast behavioral pre-selection in which we investigated the locomotory response of 5-day post-fertilization old larval fish to hyperosmotic shock. Based on this assay, we selected five lines for our lower throughput secondary adult behavioral screen. The latter screen utilized tests in which computer animated image presentation and video-tracking-based automated quantification of behavior allowed us to compare heterozygous zebrafish with their wild-type siblings on their responses to a variety of stimuli. We found significant mutation induced adult behavioral alterations in 4 out of the 5 lines analyzed, including changes in response to social or fear inducing stimuli, to handling and novelty, or in habituation to novelty. We discuss the pros and cons of behavioral phenotyping and of the use of different forward genetic methods in biomedical research with zebrafish.

  2. Evaluating the reliability of an injury prevention screening tool: Test-retest study.

    Science.gov (United States)

    Gittelman, Michael A; Kincaid, Madeline; Denny, Sarah; Wervey Arnold, Melissa; FitzGerald, Michael; Carle, Adam C; Mara, Constance A

    2016-10-01

    A standardized injury prevention (IP) screening tool can identify family risks and allow pediatricians to address behaviors. To assess behavior changes on later screens, the tool must be reliable for an individual and ideally between household members. Little research has examined the reliability of safety screening tool questions. This study utilized test-retest reliability of parent responses on an existing IP questionnaire and also compared responses between household parents. Investigators recruited parents of children 0 to 1 year of age during admission to a tertiary care children's hospital. When both parents were present, one was chosen as the "primary" respondent. Primary respondents completed the 30-question IP screening tool after consent, and they were re-screened approximately 4 hours later to test individual reliability. The "second" parent, when present, only completed the tool once. All participants received a 10-dollar gift card. Cohen's Kappa was used to estimate test-retest reliability and inter-rater agreement. Standard test-retest criteria consider Kappa values: 0.0 to 0.40 poor to fair, 0.41 to 0.60 moderate, 0.61 to 0.80 substantial, and 0.81 to 1.00 as almost perfect reliability. One hundred five families participated, with five lost to follow-up. Thirty-two (30.5%) parent dyads completed the tool. Primary respondents were generally mothers (88%) and Caucasian (72%). Test-retest of the primary respondents showed their responses to be almost perfect; average 0.82 (SD = 0.13, range 0.49-1.00). Seventeen questions had almost perfect test-retest reliability and 11 had substantial reliability. However, inter-rater agreement between household members for 12 objective questions showed little agreement between responses; inter-rater agreement averaged 0.35 (SD = 0.34, range -0.19-1.00). One question had almost perfect inter-rater agreement and two had substantial inter-rater agreement. The IP screening tool used by a single individual had excellent

  3. Test-Retest Reliability of a Serious Game for Delirium Screening in the Emergency Department.

    Science.gov (United States)

    Tong, Tiffany; Chignell, Mark; Tierney, Mary C; Lee, Jacques S

    2016-01-01

    Introduction: Cognitive screening in settings such as emergency departments (ED) is frequently carried out using paper-and-pencil tests that require administration by trained staff. These assessments often compete with other clinical duties and thus may not be routinely administered in these busy settings. Literature has shown that the presence of cognitive impairments such as dementia and delirium are often missed in older ED patients. Failure to recognize delirium can have devastating consequences including increased mortality (Kakuma et al., 2003). Given the demands on emergency staff, an automated cognitive test to screen for delirium onset could be a valuable tool to support delirium prevention and management. In earlier research we examined the concurrent validity of a serious game, and carried out an initial assessment of its potential as a delirium screening tool (Tong et al., 2016). In this paper, we examine the test-retest reliability of the game, as it is an important criterion in a cognitive test for detecting risk of delirium onset. Objective: To demonstrate the test-retest reliability of the screening tool over time in a clinical sample of older emergency patients. A secondary objective is to assess whether there are practice effects that might make game performance unstable over repeated presentations. Materials and Methods: Adults over the age of 70 were recruited from a hospital ED. Each patient played our serious game in an initial session soon after they arrived in the ED, and in follow up sessions conducted at 8-h intervals (for each participant there were up to five follow up sessions, depending on how long the person stayed in the ED). Results: A total of 114 adults (61 females, 53 males) between the ages of 70 and 104 years ( M = 81 years, SD = 7) participated in our study after screening out delirious patients. We observed a test-retest reliability of the serious game (as assessed by correlation r -values) between 0.5 and 0.8 across adjacent

  4. Utility of quick oculomotor tests for screening the vestibular system in the subacute and chronic populations.

    Science.gov (United States)

    Cohen, Helen S; Stitz, Jasmine; Sangi-Haghpeykar, Haleh; Williams, Susan P; Mulavara, Ajitkumar P; Peters, Brian T; Bloomberg, Jacob J

    2018-04-01

    The goal of this study was to determine the sensitivity and specificity of some widely used, easily administered clinical tests. Simple tests of oculomotor function have become widely used for clinical screening of patients suspected of having vestibular disorders despite a paucity of evidence showing good statistical support for their use in this highly variable population. Healthy controls with no history of otologic or neurologic disorders (n = 291) were compared to patients with known vestibular disorders (n = 62). All subjects performed passive and active head shaking, un-instrumented head impulse tests (HT), and video head impulse tests (vHIT) recorded with infrared video-oculography. For both passive and active head shaking, using presence/absence of vertigo and of nystagmus, sensitivity was low (<0.40). Sensitivity of presence/absence of saccades on HT was even lower (<0.15). On vHIT, gains were all approximately = 1.0, so sensitivity was very low (approximately 0.15-0.35). Sensitivity and specificity for presence/absence of saccades were moderately poor (less than 0.70). None of these tests are adequate for screening patients in the out-patient clinic for vestibular disorders or for screening people in epidemiologic studies to determine the prevalence of vestibular disorders.

  5. The Clock Drawing Test A review of its accuracy in screening for dementia

    Directory of Open Access Journals (Sweden)

    Ivan Aprahamian

    Full Text Available Abstract The Clock Drawing Test (CDT is a simple neuropsychometric instrument that can be easily applied to assess several cognitive functions. Over the past 20 years, the CDT has aroused considerable interest in its role for the early screening of cognitive impairment, especially in dementia. Although the CDT is considered an accurate test for dementia screening, recent studies including comparisons with structured batteries such as the CAMCOG have shown mixed results. Objectives: To investigate the importance of the CDT compared to other commonly used tests, in the diagnosis of dementia in the elderly; (2 to evaluate the reliability and correlation between available CDT scoring scales from recent studies. Methods: A systematic search in the literature was conducted in September 2008 for studies comparing CDT scoring systems and comparing the CDT with neuropsychiatric batteries. Results: Twelve studies were selected for analyses. Seven of these studies compared CDT scoring scales while five compared the CDT against the CAMCOG and the MMSE. Eight studies found good correlation and reliability between the scales and the other tests. Conclusion: Despite the mixed results in these studies, the CDT appears to be a good screening test for dementia.

  6. DEPIVIH 2: Use of three HIV testing methods in French primary care settings - ELISA laboratory screening versus two rapid point-of-care HIV tests.

    Science.gov (United States)

    Papadima, D; Gauthier, R; Prévoteau du Clary, F; Bouée, S; Conort, G; Livrozet, J-M; Taulera, O; Wajsbrot, A; Majerholc, C; Peter, J-M; Aubert, J-P

    2018-03-01

    The primary endpoint was to evaluate the use of HIV testing methods by French primary care providers: Elisa laboratory screening, instant result HIV diagnostic test and rapid result HIV diagnostic test. The secondary endpoints were the population screening rate of unknown HIV status consulting during the study period, reasons for screening and for choosing the specific screening method, the investigators' satisfaction with the rapid diagnostic test (RDT) and problems encountered. National prospective interventional study with French family physicians (FP) from December 2013 to December 2014. FPs enrolled all consenting adults consulting for an HIV screening test during a 6-month period: the choice was an Elisa laboratory test or one of the two RDTs. During the study period, 43 FPs included 981 patients. HIV screening was performed for the first time for 31.6% of patients; 767 (78.2%) Elisa laboratory test prescriptions and 214 (21.8%) RDTs were performed, leading to a screening rate of 1.3%. For 120 (15.7%) of the Elisa laboratory tests, the result was not reported and six RDTs were not valid. Nine patients were diagnosed as HIV-infected (0.9%): five with Elisa laboratory test and four with RDT. Almost 90% of FPs were willing to keep on using RDTs in their daily practice. In general practice, RDTs may be an important additional tool to traditional HIV screening. They could account for one in five tests prescribed in this context. Copyright © 2017 Elsevier Masson SAS. All rights reserved.

  7. POPULATION BASED COLORECTAL CANCER SCREENING: COMPARISON OF TWO FAECAL OCCULT BLOOD TESTS

    Directory of Open Access Journals (Sweden)

    Miren Begoña eZubero

    2014-01-01

    Full Text Available Background: The aim of screening for colorectal cancer is to improve prognosis by the detection of cancer at its early stages. In order to inform the decision on the specific test to be used in the population-based programme in the Basque Autonomous Region (Spain, we compared two immunochemical faecal occult blood quantitative tests (I-FOBT. Methods: Residents of selected study areas, aged 50-69 years, were invited to participate in the screening. Two tests based on latex agglutination (OC-Sensor and FOB Gold were randomly assigned to different study areas. A colonoscopy was offered to patients with a positive test result. The cut-off point used to classify a result as positive, according to manufacturer’s recommendations, was 100 ng/ml for both tests. Results: The invited population included 37,999 individuals. Participation rates were 61.8% (n=11,162 for OC-Sensor and 59.1% (n=11,786 for FOB Gold, (p=0.008. Positive rate for OC-Sensor was 6.6% (n=737 and 8.5% (n=1,002 for FOB Gold, (pConclusions: OC-Sensor test appears to be superior for I-FOBT based CRC screening, given its acceptance, ease of use, associated small number of errors and its screening accuracy. FOB-Gold on the other hand, has higher rate of positive values, with more colonoscopies performed, it shows higher detection incidence rates, but involves more false positives.

  8. An analysis of the duplicate testing strategy of an Irish immunochemical FOBT colorectal cancer screening programme.

    LENUS (Irish Health Repository)

    Kelley, Leanne

    2013-06-10

    AIM: This study examined the relevance of using a two sample quantitative immunochemical faecal occult blood test (iFOBT or FIT) at a high cut off stringency by the first population-based colorectal cancer (CRC) pilot screening programme in Ireland. METHOD: Approximately ten thousand individuals between the ages of 50-74 years were invited to perform two consecutive FITs. These were analysed in tandem using the OC-Sensor and participants with at least one positive result with a haemoglobin cut off for positivity at 100 ng\\/ml were offered colonoscopy. RESULTS: A total of 5023 (52%) (2177 (43%) male; 2846 (57%) female) individuals with a median age of 64 years participated. At least one positive FIT test was detected from 514 (10%) individuals. From the 419 (82%) patients who proceeded to colonoscopy 17 (4%) had CRC and 132(33%) had an advanced adenoma. The detection rate for these screen relevant lesions was 3% (95% CIs = 2.5% - 3.5%) and the FIT positive + colonoscopy detection rate was 36% (95% CI = 31% - 40%). The numbers needed to colonoscope to find an advanced lesion was 2.8. The two test system detected four (23.5%) additional patients with CRC and 37 (28%) with an advanced adenoma compared with a single test. CONCLUSION: The CRC miss rate estimated for a single test (23.5%) was unacceptably high when the goal was to maximize the discovery of advanced lesions in the initial screening round. We conclude that the two test protocol at a high cut off threshold is suitable to optimize FIT screening in Ireland. This article is protected by copyright. All rights reserved.

  9. Performance and diagnostic usefulness of commercially available enzyme linked immunosorbent assay and rapid kits for detection of HIV, HBV and HCV in India.

    Science.gov (United States)

    Maity, Susmita; Nandi, Srijita; Biswas, Subrata; Sadhukhan, Salil Kumar; Saha, Malay Kumar

    2012-11-26

    HIV, HBV and HCV pose a major public health problem throughout the world. Detection of infection markers for these agents is a major challenge for testing laboratories in a resource poor setting. As blood transfusion is an important activity saving millions of live every year, it also carries a risk of transfusion transmissible infections caused by these fatal blood borne pathogens if the quality of testing is compromised. Conventional ELISA is regarded as the mostly used screening technique but due to limitations like high cost, unavailability in many blood banks and testing sites, involvement of costly instruments, time taking nature and requirement of highly skilled personnel for interpretation, rapid tests are gaining more importance and warrants comparison of performance. A comparative study between these two techniques has been performed using commercially available diagnostic kits to assess their efficacy for detection of HIV, HBV and HCV infections. Rapid kits were more efficient in specificity with synthetic antigens along with high PPV than ELISA in most cases. Comparison between different ELISA kits revealed that Microlisa HIV and Hepalisa (J. Mitra & Co. Pvt. Ltd.); ERBA LISA HIV1 + 2, ERBA LISA Hepatitis B and ERBA LISA HCV (Transasia Bio-medicals Ltd.) gives uniform result with good performance in terms of sensitivity, specificity, PPV, NPV and efficiency, whereas, Microlisa HCV (J. Mitra & Co. Pvt. Ltd.), Microscreen HBsAg ELISA and INNOVA HCV (Span Diagnostics Ltd.) did not perform well. Rapid kits were also having high degree of sensitivity and specificity (100%) except in HIV Comb and HCV Comb (J. Mitra & Co. Pvt. Ltd.). The kit efficiency didn't vary significantly among different companies and lots in all the cases except for HCV ELISA showing statistically significant variation (p bank. For availability of quality commercial diagnostic assays, evaluation of kit may be helpful.

  10. Knowledge of parents regarding newborn screening test, after accessing the website “Babies’ Portal” - Heel prick test

    Directory of Open Access Journals (Sweden)

    Caroline Antonelli Mendes

    Full Text Available ABSTRACT Purpose: to assess the knowledge of mothers about the heel prick test, develop contents on this test to make it available on the "Babies’ Portal" website, evaluate and validate the informative material developed. Methods: this study was conducted in three stages, that is, the first stage which is about a descriptive study involving 105 mothers of newborn children before performing the neonatal screening "Heel Prick Test", the second one consisting in the development of the website "Babies’ Portal", and the third stage, the evaluation and validation of this material carried out by 20 parents of children between zero and 36 months old, who underwent the neonatal screening Heel Prick Test by accessing the website “Babies’ Portal”. Results: although the interviewed mothers knew that their children had the right to be tested, they showed no knowledge of the diseases that can be prevented, time of diagnosis, nor the consequences arising from the lack of early diagnosis and treatment. The website creation and validation gathered basic information about the Heel Prick Test, and the participants regarded the content from satisfactory to excellent. Conclusion: it is necessary that families know not only about the procedures their children will undergo, but also the reason they are performed and the consequences of failing in doing so.

  11. Negative HPV screening test predicts low cervical cancer risk better than negative Pap test

    Science.gov (United States)

    Based on a study that included more than 1 million women, investigators at NCI have determined that a negative test for HPV infection compared to a negative Pap test provides greater safety, or assurance, against future risk of cervical cancer.

  12. Performance Evaluation of a Novel Chemiluminescence Assay Detecting Treponema Pallidum Antibody as a Syphilis Screening Method.

    Science.gov (United States)

    Chen, Qixia; An, Jingna; Rao, Chenli; Wang, Tingting; Li, Dongdong; Feng, Shu; Tao, Chuanmin

    2016-01-01

    Syphilis is a major concern to global public health with increasing incidence. So its screening test should have sufficient sensitivity and specificity. We evaluated the performance of the Lumipulse G TP-N assay detection for syphilis screening and compared it with the InTec ELISA test kit for TP, which is widely used. Samples of several patient groups including 133 clinical and serologically characterized syphilitic sera, 175 samples containing potentially interfering agents, and 2290 unselected samples submitted for routine screening were detected by both the Lumipulse G TP-N assay and the InTec ELISA test kit for TP. Inconsistent samples were confirmed by RecomLine Treponema IgG, IgM immunoblot. Coefficient of variations of the Lumipulseo G TP-N assay at both levels were below 5% and of the InTec ELISA test kit for TP both over 5%. The sensitivity of the Lumipulse G TP-N assay and the InTec ELISA test kit for TP were 100% for all stages of syphilis. The two methods had consistent analytical specificity of 100% (95% CI: 97.21 - 100.00), while the clinical specificity was 100% (95% CI: 99.79 - 100.00) and 99.82% (95% CI: 99.51 - 99.94), respectively. Between them, Spearman's correlation coefficient was 0.455 and kappa value was 0.986. The overall sensitivity and specificity of the Lumipulse G TP-N assay was higher than the InTec ELISA test kit for TP (sensitivity: 100.0 versus 99.5, specificity: 100.0 versus 99.8). The automated Lumipulse G TP-N assay demonstrated excellent diagnostic sensitivity and specificity when evaluated as a screening test for syphilis. Thus, it can be an alternative to the treponemal screening test.

  13. [Costs of Chagas' disease screening test in blood donors in two Colombian blood banks, 2015].

    Science.gov (United States)

    Alvis, Nelson José; Díaz, Diana Patricia; Castillo, Liliana; Alvis, Nelson Rafael; Bermúdez, María Isabel; Berrío, Olga Maritza; Beltrán, Mauricio; Castañeda-Orjuela, Carlos Andrés

    2018-03-15

    Transfusion is a mechanism of transmission of Chagas' disease. There are no studies on the costs of the screening test in Colombian blood banks. To estimate the costs of the screening test for Chagas' disease among blood donors in two Colombian blood banks, 2015. We conducted a micro-costing study from the perspective of the health care provider to estimate the cost of Chagas' disease testing in two blood banks, Banco de Sangre de la Cruz Roja, Seccional Bolívar, and Banco de Sangre del Hospital de Yopal, Casanare, taking into account four cost categories: 1) Administrative costs: public services and insurance costs were calculated based on the blood bank area in square meters; 2) capital costs: building and equipment costs that were annualized using a 3% discount rate and a lifespan of 20 years for building and five for equipment; 3) costs of Chagas' disease test materials and reagents adjusted by blood bank production level, and 4) costs of staff in charge of Chagas' disease test processing. The costs of transfusion bagsand immunohematology tests are also reported. The cost of Chagas' disease test in the blood bank of Seccional Bolívar was COP$ 37,804 (USD$ 12), and the blood bag and immunohematology test costs were COP$ 25,941 (USD$ 8.2) and COP$ 6,800 (USD$ 2.2), respectively. In the blood bank of Yopal, Casanare, the costs were COP$ 77,384 (USD$ 24.6), COP$ 30,141 (USD$ 9.6) and COP$ 12,627 (USD$ 4), respectively. Personnel cost accounted for the highest percentage of the total cost for both blood banks (47.5% in Seccional Bolívar, and 55.7% in Yopal, Casanare). Our results are an important input for the planning of services and cost-effectiveness studies for screening tests for Chagas' disease in Colombian blood banks.

  14. The King-Devick test as a concussion screening tool administered by sports parents.

    Science.gov (United States)

    Leong, D F; Balcer, L J; Galetta, S L; Liu, Z; Master, C L

    2014-02-01

    Sports-related concussion has received increasing awareness due to short- and long-term neurologic sequelae seen among athletes. The King-Devick (K-D) test captures impairment of eye movements and other correlates of suboptimal brain function. We investigated the K-D test as a screening for concussion when administered by layperson sports parents in a cohort of amateur boxers. The K-D test was administered pre-fight and post-fight by laypersons masked to the head trauma status of each athlete. Matches were watched over by a ringside physician and boxing trainer. Athletes with suspected head trauma received testing with the Military Acute Concussion Evaluation (MACE) by the ringside physician to determine concussion status. Athletes sustaining concussion were compared to the athletes screened using the K-D test. Post-fight K-D scores were lower (better) than the best baseline score (41 vs. 39.3 s, P=0.34, Wilcoxon signed-rank test), in the absence of concussion. One boxer sustained a concussion as determined by the ringside physician. This boxer was accurately identified by the layperson K-D testers due to a worsening in K-D test compared to baseline (3.2 seconds) and an increased number of errors. High levels of test-retest reliability were observed (intraclass correlation coefficient 0.90 [95% CI 0.84-0.97]). Additionally, 6 boxers who participated in multiple bouts showed no worsening of their K-D times further supporting that scores are not affected by the fatigue associated with sparring. The K-D test is a rapid sideline screening tool for concussion that can be effectively administered by non-medically trained laypersons.

  15. Automated Cervical Screening and Triage, Based on HPV Testing and Computer-Interpreted Cytology.

    Science.gov (United States)

    Yu, Kai; Hyun, Noorie; Fetterman, Barbara; Lorey, Thomas; Raine-Bennett, Tina R; Zhang, Han; Stamps, Robin E; Poitras, Nancy E; Wheeler, William; Befano, Brian; Gage, Julia C; Castle, Philip E; Wentzensen, Nicolas; Schiffman, Mark

    2018-04-11

    State-of-the-art cervical cancer prevention includes human papillomavirus (HPV) vaccination among adolescents and screening/treatment of cervical precancer (CIN3/AIS and, less strictly, CIN2) among adults. HPV testing provides sensitive detection of precancer but, to reduce overtreatment, secondary "triage" is needed to predict women at highest risk. Those with the highest-risk HPV types or abnormal cytology are commonly referred to colposcopy; however, expert cytology services are critically lacking in many regions. To permit completely automatable cervical screening/triage, we designed and validated a novel triage method, a cytologic risk score algorithm based on computer-scanned liquid-based slide features (FocalPoint, BD, Burlington, NC). We compared it with abnormal cytology in predicting precancer among 1839 women testing HPV positive (HC2, Qiagen, Germantown, MD) in 2010 at Kaiser Permanente Northern California (KPNC). Precancer outcomes were ascertained by record linkage. As additional validation, we compared the algorithm prospectively with cytology results among 243 807 women screened at KPNC (2016-2017). All statistical tests were two-sided. Among HPV-positive women, the algorithm matched the triage performance of abnormal cytology. Combined with HPV16/18/45 typing (Onclarity, BD, Sparks, MD), the automatable strategy referred 91.7% of HPV-positive CIN3/AIS cases to immediate colposcopy while deferring 38.4% of all HPV-positive women to one-year retesting (compared with 89.1% and 37.4%, respectively, for typing and cytology triage). In the 2016-2017 validation, the predicted risk scores strongly correlated with cytology (P < .001). High-quality cervical screening and triage performance is achievable using this completely automated approach. Automated technology could permit extension of high-quality cervical screening/triage coverage to currently underserved regions.

  16. New RIA kit for determination of progesterone in cow milk

    International Nuclear Information System (INIS)

    Byszewska-Szpocinska, E.; Markiewicz, A.

    2006-01-01

    The determination of progesterone concentration in whole and fat-free milk 19-24 days after conception enables to distinguish fertile and non-fertile insemination, which is important in cattle breeding. The aim of this work was to develop a simple and quick radioimmunoassay test for the determination of progesterone in cow milk. Two types of solid-phase tubes coated with specific polyclonal anti-progesterone antibody from ORION Diagnostica and BIOSOURCE International, two different progesterone derivatives viz. progesterone-3- carboxymethyl oxime (CMO) and progesterone-11α-hemisuccinate (HS) conjugated to 125 I-histamine and the HPLC system with Lichrospher RP-18 column along with 65% acetonitrile/water as eluent to purify the tracers were used to carry out this work. Progesterone-3CMO- 125 I-histamine had a retention time of 13.2 min and progesterone-11α-hemisuccinate- 125 I-histamine had a retention time of 7.8 min. Two kinds of kits (kit I and kit II) were prepared, first with progesterone-3CMO- 125 I-histamine as the tracer and coated tubes from Progesterone Veterinary RIA kit of ORION Diagnostica and the second with progesterone-11αHS- 125 I-histamine as the tracer and coated tubes from Progesterone Veterinary RIA kit from BIOSOURCE International. Progesterone from Sigma and selected fat-free cow's milk without progesterone as zero progesterone milk matrix were used for standard preparation. The optimal assay procedure was as follows: 50μL standards, controls and fat-free milk samples were pipetted into coated tubes followed by addition of 500μL of diluted tracer. The tubes were incubated for 2h in case of kit I and 3h for kit II at RT. After the incubation, the tubes were decanted and counted. The assay range was 0 to 270 nmol/L for kit I and 0 to 300 nmol/L for kit II. The sensitivity of the kit with ORION coated tubes was better (0.8 nmol/L) than that of BIOSOURCE tubes which was 1.5 nmol/L. Validation of these assays in terms of specificity, accuracy

  17. Rationale, design, and results of the first screening round of a comprehensive, register-based, Chlamydia screening implementation programme in the Netherlands

    Directory of Open Access Journals (Sweden)

    Koekenbier Rik H

    2010-10-01

    Full Text Available Abstract Background Implementing Chlamydia trachomatis screening in the Netherlands has been a point of debate for several years. The National Health Council advised against implementing nationwide screening until additional data collected from a pilot project in 2003 suggested that screening by risk profiles could be effective. A continuous increase in infections recorded in the national surveillance database affirmed the need for a more active approach. Here, we describe the rationale, design, and implementation of a Chlamydia screening demonstration programme. Methods A systematic, selective, internet-based Chlamydia screening programme started in April 2008. Letters are sent annually to all 16 to 29-year-old residents of Amsterdam, Rotterdam, and selected municipalities of South Limburg. The letters invite sexually active persons to login to http://www.chlamydiatest.nl with a personal code and to request a test kit. In the lower prevalence area of South Limburg, test kits can only be requested if the internet-based risk assessment exceeds a predefined value. Results We sent invitations to 261,025 people in the first round. One-fifth of the invitees requested a test kit, of whom 80% sent in a sample for testing. The overall positivity rate was 4.2%. Conclusions This programme advances Chlamydia control activities in the Netherlands. Insight into the feasibility, effectiveness, cost-effectiveness, and impact of this large-scale screening programme will determine whether the programme will be implemented nationally.

  18. Supply kits for antenatal and childbirth care: a systematic review.

    Science.gov (United States)

    Aleman, Alicia; Tomasso, Giselle; Cafferata, María Luisa; Colomar, Mercedes; Betran, Ana Pilar

    2017-12-13

    It is critical to increase the uptake of interventions proven to be effective to improve maternal and perinatal outcomes. Supply kits have been suggested to be a feasible strategy designed to ensure timely availability and effective follow-up of care. We conducted a systematic review to summarize the evidence on the uptake, effectiveness and safety of supply kits for maternal care. MEDLINE, the Cochrane Pregnancy and Childbirth Group's Trials Register, Campbell Collaboration, Lilacs, Embase and unpublished studies were searched. Studies that reported the efficacy, safety and use of supply kits for maternal healthcare were eligible. Participants were pregnant women or in childbirth. Supply kits were defined as a collection of medicines, supplies or instruments packaged together with the aim of conducting a healthcare task. Two reviewers independently performed the screening, data extraction, and methodological and quality assessment. 24 studies were included: 4 of them were systematic reviews and 20 primary studies. Eighteen studies evaluated a so-called "clean delivery kit". In all but two studies, the kits were used by more than half of the participants. A meta-analysis was deemed inappropriate due to the heterogeneity in study design, in the components of the interventions implemented, in the content of the kits, and in outcomes. Nine studies assessed neonatal outcomes and found statistically significant reductions in cord infection, sepsis and tetanus-related mortality in the intervention group. Three studies showed evidence of reduced neonatal mortality (OR 0.52, 0.60 and 0.71) with statistically significant confidence intervals in all cases. Four studies reported odd ratios for maternal mortality, but only one showed evidence of a statistically significant decrease in this outcome but it was ascribed to hand washing prior to childbirth and not with the use of kits. This review suggests potential benefits in the use of supply kits to improve maternal and

  19. HPV testing for primary cervical screening: Laboratory issues and evolving requirements for robust quality assurance.

    Science.gov (United States)

    Carozzi, Francesca Maria; Del Mistro, Annarosa; Cuschieri, Kate; Frayle, Helena; Sani, Cristina; Burroni, Elena

    2016-03-01

    This review aims to highlight the importance of Quality Assurance for Laboratories performing HPV test for Cervical Cancer Screening. An HPV test, to be used as primary screening test, must be validated according to international criteria, based on comparison of its clinical accuracy to HC2 or GP5+/6+ PCR-EIA tests. The number of validated platforms is increasing and appropriate Quality Assurance Programs (QAPs) which can interrogate longitudinal robustness and quality are paramount. This document describes the following topics: (1) the characteristics of an HPV laboratory and the personnel training needs, to ensure an elevated quality of the entire process and the optimal use of the resources; (2) the Quality Assurance, as both internal (IQA) and external quality assessment (EQA) systems, to be implemented and performed, and the description of the existing EQAs, including limitations; (3) general considerations for an optimal EQA program for hrHPV primary screening Due to the importance of Quality Assurance for this field, international efforts are necessary to improve QA International Collaboration. Copyright © 2015 Elsevier B.V. All rights reserved.

  20. Easier operation and similar power of 10 g monofilament test for screening diabetic peripheral neuropathy.

    Science.gov (United States)

    Zhang, Qi; Yi, Na; Liu, Siying; Zheng, Hangping; Qiao, Xiaona; Xiong, Qian; Liu, Xiaoxia; Zhang, Shuo; Wen, Jie; Ye, Hongying; Zhou, Linuo; Li, Yiming; Hu, Renming; Lu, Bin

    2018-01-01

    Objective The 10 g Semmes-Weinstein monofilament evaluation (SWME) of 4 sites on each foot is recommended for distal symmetric polyneuropathy screening and diagnosis. A similar method has been proposed to diagnose 'high-risk' (for ulceration) feet, using 3 sites per foot. This study compared the effectiveness of SWME for testing 3, 4 and 10 sites per foot to identify patients with diabetic neuropathy. Methods We included 3497 subjects in a SWME of 10 sites; records from the 10-site SWME were used for a SWME of 3 and 4 sites. Neuropathy symptom scores and neuropathy deficit scores were evaluated to identify patients with diabetic peripheral neuropathy. Results The sensitivities of the 10 g SWME for 3, 4 and 10 sites were 17.8%, 19.0% and 22.4%, respectively. The Kappa coefficients for the SWME tests of 3, 4 and 10 sites were high (range: 0.78-0.93). Conclusions There were no significant differences in the effectiveness of 3-, 4- and 10-site SWME testing for diabetic peripheral neuropathy screening. SWME testing of 3 sites on each foot may be sufficient to screen for diabetic neuropathy.

  1. 21 CFR 862.1055 - Newborn screening test system for amino acids, free carnitine, and acylcarnitines using tandem...

    Science.gov (United States)

    2010-04-01

    ..., free carnitine, and acylcarnitines using tandem mass spectrometry. 862.1055 Section 862.1055 Food and... screening test system for amino acids, free carnitine, and acylcarnitines using tandem mass spectrometry. (a) Identification. A newborn screening test system for amino acids, free carnitine, and acylcarnitines using tandem...

  2. Rapid detection of methicillin resistance in Staphylococcus aureus isolates by the MRSA-screen latex agglutination test

    NARCIS (Netherlands)

    W.B. van Leeuwen (Willem); C. van Pelt (Cindy); A. Luijendijk (Ad); H.A. Verbrugh (Henri); W.H.F. Goessens (Wil)

    1999-01-01

    textabstractThe slide agglutination test MRSA-Screen (Denka Seiken Co., Niigata, Japan) was compared with the mecA PCR ("gold standard") for the detection of methicillin resistance in Staphylococcus aureus. The MRSA-Screen test detected the penicillin-binding protein 2a

  3. De item-reeks van de cognitieve screening test vergeleken met die van de mini-mental state examination

    NARCIS (Netherlands)

    Schmand, B.; Deelman, B. G.; Hooijer, C.; Jonker, C.; Lindeboom, J.

    1996-01-01

    The items of the ¿mini-mental state examination' (MMSE) and a Dutch dementia screening instrument, the ¿cognitive screening test' (CST), as well as the ¿geriatric mental status schedule' (GMS) and the ¿Dutch adult reading test' (DART), were administered to 4051 elderly people aged 65 to 84 years.

  4. Comparison among single-phase test, automated screening method and GC/MS for the traceability of ketamine in urine

    Directory of Open Access Journals (Sweden)

    Alice Visione

    2016-12-01

    CONCLUSION Following the law indications, ketamine is not searched: this limit does not make the authorities able to apply the penalties expected for road laws violations. The automation is essential to guarantee the reliability of toxicological screening tests, especially to medico-legal significance. This results highlight the absolutely necessity of the execution of the confirmation test, successively to screening analysis.

  5. How many cervical cancer cases can potentially be prevented using a more sensitive screening test at young age?

    NARCIS (Netherlands)

    I.M.C.M. de Kok (Inge); J.M. van Rosmalen (Joost); K. Rozemeijer (Kirsten); C. Penning (Corine); M. van Ballegooijen (Marjolein)

    2014-01-01

    textabstractThe human papilloma virus (HPV) DNA test has higher sensitivity than cytology for cervical cancer screening. Therefore, cervical cancer cases that are missed by cytology could potentially be identified if we use primary HPV testing. Studies showed that HPV screening is the preferred

  6. Evaluation of a new website design for iwantthekit for chlamydia, gonorrhea, and trichomonas screening.

    Science.gov (United States)

    Kuder, Margaret; Goheen, Mary Jett; Dize, Laura; Barnes, Mathilda; Gaydos, Charlotte A

    2015-05-01

    The www.iwantthekit.org provides Internet-based, at-home sexually transmitted infection screening. The Web site implemented an automated test result access system. To evaluate potential deleterious effects of the new system, we analyzed demographics, Web site usage, and treatment. The post-Web site design captured more participant information and no decrease in requests, kit return, or treatment adherence.

  7. Computerized portable microwave hyperthermia quality assurance kit

    International Nuclear Information System (INIS)

    Cheung, A.Y.; Neyzari, A.

    1985-01-01

    A computerized quality assurance kit to provide precise measurement and calibration of microwave power and temperature, as well as capabilities to map SAR (Specific absorption rate) distribution in phantoms; and survey of hazardous microwave leakage has been designed. The kit is also capable of performing corelation studies on the relationship between SAR and net microwave power delivered at various anatomical sites. The kit consists of a portable microcomputer, a time-multiplexed A/D converter, a 4-channel dual directional microwave power monitor, a 4-channel thin-wire thermocouple thermometry system, an electronic thermal calibrator, a microwave leakage hazard survey meter, and a dynamic phantom tank for dosimetric analysis. Comparative performance studies were made against NBS-traceable power and temperature standards, non-perturbing optical temperature sensors, and established power and temperature measurement devices. The test results indicate that this instrument is providing its user with measurement accuracy of 0.1 0 C in temperature, 10% accuracy in power. The thin-wire thermocouple, with computer assisted error compensation, performs equally well in a strong microwave field in comparison with non-perturbing optical temperature sensors

  8. The diagnosis value of BV combined test kit for non specific bacterial vaginitis%细菌性阴道病联合测定试剂盒对非特异细菌性阴道炎的诊断价值

    Institute of Scientific and Technical Information of China (English)

    王婷玉

    2011-01-01

    目的 探讨细菌性阴道病(BV)联合测定试剂盒对阴道炎的诊断效能,评估其临床价值.方法 采集妇科门诊患者阴道分泌物进行白带常规检查(白细胞、上皮细胞、阴道毛滴虫、真菌孢子),同时用BV联合测定试剂盒检测BV.结果 1 200例标本中,共检出滴虫阳性检出率为4.4%,真菌孢子为10.8%,BV为11.9%.结论 对阴道炎患者阴道分泌物同时进行滴虫、真菌孢子、BV检测,能更好反映阴道炎患者的病原体感染状况,有利于临床医生对症治疗;BV检测可作为妇科门诊患者白带常规筛查项目进行推广应用.%Objective To investigate the diagnostic efficacy of the bacterial vaginosis(BV) combined test kit and to assess the clinical value. Methods Collect the vaginal secrtion samples from the patients with vaginitis in the Gynecologic Outpatient Department, take the leucorrhea routine examination which included leukocyte、 epithelial trichomonas vaginalis 、fungal spores, and use the BV combined test kit to detect BV. Results In 1 200 cases, 4.4% were positive with trichomonas vagiralis, 10. 8% with fungal spores and 11.9 % with BV. Conclusion Simultaneously, the trichomonas vaginalis,fungal spores and BV of the vaginal secretion from the vaginitis patients were detected, which can better reflect the status of pathogen infection of vaginal secretion from the padents and help clinical doctors to make symptomatic treatment. So BV detection can be used as screening program of leukorrhea routine examination for the outpatients from Gynaecology Department in the local area.

  9. The Addenbrooke's Cognitive Examination Revised (ACE-R): a brief cognitive test battery for dementia screening.

    Science.gov (United States)

    Mioshi, Eneida; Dawson, Kate; Mitchell, Joanna; Arnold, Robert; Hodges, John R

    2006-11-01

    There is a clear need for brief, but sensitive and specific, cognitive screening instruments as evidenced by the popularity of the Addenbrooke's Cognitive Examination (ACE). We aimed to validate an improved revision (the ACE-R) which incorporates five sub-domain scores (orientation/attention, memory, verbal fluency, language and visuo-spatial). Standard tests for evaluating dementia screening tests were applied. A total of 241 subjects participated in this study (Alzheimer's disease=67, frontotemporal dementia=55, dementia of Lewy Bodies=20; mild cognitive impairment-MCI=36; controls=63). Reliability of the ACE-R was very good (alpha coefficient=0.8). Correlation with the Clinical Dementia Scale was significant (r=-0.321, pcognitive dysfunction. Copyright (c) 2006 John Wiley & Sons, Ltd.

  10. A comparison of hamstring muscle activity during different screening tests for non-contact ACL injury

    DEFF Research Database (Denmark)

    Husted, Rasmus S; Bencke, Jesper; Andersen, Lars Louis

    2016-01-01

    phenomenon and thereby observable independently of the type of clinical screening tests used is not known. This cross sectional study investigated the rank correlation of knee joint neuromuscular activity between three different ACL injury risk screening tests. METHODS: Sixty-two adolescent female elite......BACKGROUND: Reduced ability to activate the medial hamstring muscles during a sports-specific sidecutting movement has been found to be a potential risk factor for non-contact ACL injury. However, whether a reduced ability to activate the medial hamstring muscle is a general neuromuscular...... football and handball players (16.7±1.3years) participated in the study. Using surface electromyography (EMG) assessment, the neuromuscular activity of medial hamstring muscle (semitendinosus, ST), lateral hamstring muscle (biceps femoris, BF) and quadriceps muscle (vastus lateralis, VL) were monitored...

  11. Follow-up of abnormal or inadequate test results in the Danish Cervical Cancer Screening Program

    DEFF Research Database (Denmark)

    Kristiansen, Bettina Kjær

    2014-01-01

    Denmark has a higher incidence of cervical cancer than other Nordic countries, although all Danish women (aged 23–65) are screened regularly to identify possible cervical dysplasia or asymptomatic invasive cancer. Annually 40 000 women receives an abnormal or inadequate test result and a follow......-up recommendation. However problems with delayed follow-up may threaten the effectiveness of the Danish Cervical Cancer Screening Program, as 20% of women are delayed and dysplasia potentially can progress into cancer. Delayed follow-up is found in situations where women either consciously or unconsciously postpone...... up will be sent to the women (RCT). The intention is to ensure that all women will be notified about the test result, quickly, homogenously and in layman’s written language, still with the opportunity to contact or be contacted by the GP, if there is special needs. Furthermore, it is assumed that GP...

  12. Terrestrial Eco-Toxicological Tests as Screening Tool to Assess Soil Contamination in Krompachy Area

    Science.gov (United States)

    Ol'ga, Šestinová; Findoráková, Lenka; Hančuľák, Jozef; Fedorová, Erika; Tomislav, Špaldon

    2016-10-01

    In this study, we present screening tool of heavy metal inputs to agricultural and permanent grass vegetation of the soils in Krompachy. This study is devoted to Ecotoxicity tests, Terrestrial Plant Test (modification of OECD 208, Phytotoxkit microbiotest on Sinapis Alba) and chronic tests of Earthworm (Dendrobaena veneta, modification of OECD Guidelines for the testing of chemicals 317, Bioaccumulation in Terrestrial Oligochaetes) as practical and sensitive screening method for assessing the effects of heavy metals in Krompachy soils. The total Cu, Zn, As, Pb and Hg concentrations and eco-toxicological tests of soils from the Krompachy area were determined of 4 sampling sites in 2015. An influence of the sampling sites distance from the copper smeltery on the absolutely concentrations of metals were recorded for copper, lead, zinc, arsenic and mercury. The highest concentrations of these metals were detected on the sampling sites up to 3 km from the copper smeltery. The samples of soil were used to assess of phytotoxic effect. Total mortality was established at earthworms using chronic toxicity test after 7 exposure days. The results of our study confirmed that no mortality was observed in any of the study soils. Based on the phytotoxicity testing, phytotoxic effects of the metals contaminated soils from the samples 3KR (7-9) S.alba seeds was observed.

  13. Primary care visit use after positive fecal immunochemical test for colorectal cancer screening.

    Science.gov (United States)

    Hillyer, Grace Clarke; Jensen, Christopher D; Zhao, Wei K; Neugut, Alfred I; Lebwohl, Benjamin; Tiro, Jasmin A; Kushi, Lawrence H; Corley, Douglas A

    2017-10-01

    For some patients, positive cancer screening test results can be a stressful experience that can affect future screening compliance and increase the use of health care services unrelated to medically indicated follow-up. Among 483,216 individuals aged 50 to 75 years who completed a fecal immunochemical test to screen for colorectal cancer at a large integrated health care setting between 2007 and 2011, the authors evaluated whether a positive test was associated with a net change in outpatient primary care visit use within the year after screening. Multivariable regression models were used to evaluate the relationship between test result group and net changes in primary care visits after fecal immunochemical testing. In the year after the fecal immunochemical test, use increased by 0.60 clinic visits for patients with true-positive results. The absolute change in visits was largest (3.00) among individuals with positive test results who were diagnosed with colorectal cancer, but significant small increases also were found for patients treated with polypectomy and who had no neoplasia (0.36) and those with a normal examination and no polypectomy performed (0.17). Groups of patients who demonstrated an increase in net visit use compared with the true-negative group included patients with true-positive results (odds ratio [OR], 1.60; 95% confidence interval [95% CI], 1.54-1.66), and positive groups with a colorectal cancer diagnosis (OR, 7.19; 95% CI, 6.12-8.44), polypectomy/no neoplasia (OR, 1.37; 95% CI, 1.27-1.48), and normal examination/no polypectomy (OR, 1.24; 95% CI, 1.18-1.30). Given the large size of outreach programs, these small changes can cumulatively generate thousands of excess visits and have a substantial impact on total health care use. Therefore, these changes should be included in colorectal cancer screening cost models and their causes investigated further. Cancer 2017;123:3744-3753. © 2017 American Cancer Society. © 2017 American Cancer Society.

  14. What women want. Women's preferences for the management of low-grade abnormal cervical screening tests: a systematic review

    DEFF Research Database (Denmark)

    Frederiksen, Maria Eiholm; Lynge, E; Rebolj, M

    2012-01-01

    Please cite this paper as: Frederiksen M, Lynge E, Rebolj M. What women want. Women's preferences for the management of low-grade abnormal cervical screening tests: a systematic review. BJOG 2011; DOI: 10.1111/j.1471-0528.2011.03130.x. Background If human papillomavirus (HPV) testing will replace...... cytology in primary cervical screening, the frequency of low-grade abnormal screening tests will double. Several available alternatives for the follow-up of low-grade abnormal screening tests have similar outcomes. In this situation, women's preferences have been proposed as a guide for management....... Selection criteria Studies asking women to state a preference between active follow-up and observation for the management of low-grade abnormalities on screening cytology or HPV tests. Data collection and analysis Information on study design, participants and outcomes was retrieved using a prespecified form...

  15. Negative screening tests in classical galactosaemia caused by S135L homozygosity.

    LENUS (Irish Health Repository)

    Crushell, E

    2009-06-01

    Classical galactosaemia is relatively common in Ireland due to a high carrier rate of the Q188R GALT mutation. It is screened for using a bacterial inhibition assay (BIA) for free galactose. A Beutler assay on day one of life is performed only in high risk cases (infants of the Traveller community and relatives of known cases). A 16-month-old Irish-born boy of Nigerian origin was referred for investigation of developmental delay, and failure to thrive. He had oral aversion to solids and his diet consisted of cow\\'s milk and milk-based cereal mixes. He was found to have microcephaly, weight <2nd percentile, hepatomegaly and bilateral cataracts. Coagulation screen was normal and transaminases were slightly elevated. His original newborn screen was reviewed and confirmed to have been negative; urinary reducing substances on three separate occasions were negative. Beutler assay demonstrated "absent" red cell galactose-1-phosphate uridyltransferase (GALT) activity. GALT enzyme activity was <0.5 gsubs\\/h per gHb confirming classical galactosaemia. Gal-1-P was elevated at 1.88 micromol\\/gHb. Mutation analysis of the GALT gene revealed S135L homozygosity. S135L\\/S135L galactosaemia is associated with absent red cell GALT activity but with approximately 10% activity in other tissues such as the liver and intestines, probably explaining the negative screening tests and the somewhat milder phenotype associated with this genotype. The patient was commenced on galactose-restricted diet; on follow-up at 2 years of age, growth had normalized but there was global developmental delay. In conclusion, galactosaemia must be considered in children who present with poor growth, hepatomegaly, developmental delay and cataracts and GALT enzyme analysis should be a first line test in such cases. Non-enzymatic screening methods such as urinary reducing substances and BIA for free galactose are not reliable in S135L homozygous galactosaemia.

  16. The comparative cost-effectiveness of colorectal cancer screening using faecal immunochemical test vs. colonoscopy.

    Science.gov (United States)

    Wong, Martin C S; Ching, Jessica Y L; Chan, Victor C W; Sung, Joseph J Y

    2015-09-04

    Faecal immunochemical tests (FITs) and colonoscopy are two common screening tools for colorectal cancer(CRC). Most cost-effectiveness studies focused on survival as the outcome, and were based on modeling techniques instead of real world observational data. This study evaluated the cost-effectiveness of these two tests to detect colorectal neoplastic lesions based on data from a 5-year community screening service. The incremental cost-effectiveness ratio (ICER) was assessed based on the detection rates of neoplastic lesions, and costs including screening compliance, polypectomy, colonoscopy complications, and staging of CRC detected. A total of 5,863 patients received yearly FIT and 4,869 received colonoscopy. Compared with FIT, colonoscopy detected notably more adenomas (23.6% vs. 1.6%) and advanced lesions or cancer (4.2% vs. 1.2%). Using FIT as control, the ICER of screening colonoscopy in detecting adenoma, advanced adenoma, CRC and a composite endpoint of either advanced adenoma or stage I CRC was US$3,489, US$27,962, US$922,762 and US$23,981 respectively. The respective ICER was US$3,597, US$439,513, -US$2,765,876 and US$32,297 among lower-risk subjects; whilst the corresponding figure was US$3,153, US$14,852, US$184,162 and US$13,919 among higher-risk subjects. When compared to FIT, colonoscopy is considered cost-effective for screening adenoma, advanced neoplasia, and a composite endpoint of advanced neoplasia or stage I CRC.

  17. In Vitro Screening of Environmental Chemicals for Targeted Testing Prioritization: The ToxCast Project

    OpenAIRE

    Judson, Richard S.; Houck, Keith A.; Kavlock, Robert J.; Knudsen, Thomas B.; Martin, Matthew T.; Mortensen, Holly M.; Reif, David M.; Rotroff, Daniel M.; Shah, Imran; Richard, Ann M.; Dix, David J.

    2009-01-01

    Background Chemical toxicity testing is being transformed by advances in biology and computer modeling, concerns over animal use, and the thousands of environmental chemicals lacking toxicity data. The U.S. Environmental Protection Agency?s ToxCast program aims to address these concerns by screening and prioritizing chemicals for potential human toxicity using in vitro assays and in silico approaches. Objectives This project aims to evaluate the use of in vitro assays for understanding the ty...

  18. Qualidade do solo avaliada pelo "Soil Quality Kit Test" em dois experimentos de longa duração no Rio Grande do Sul Soil Quality Evaluated by "Soil Quality Kit" in two long-term soil management experiments in Rio Grande do Sul State, Brazil

    Directory of Open Access Journals (Sweden)

    Telmo Jorge Carneiro Amado

    2007-02-01

    agregados, N-NO3- + N-NO2- e respiração do solo foram os mais eficientes em discriminar a QS. O KQS foi eficiente em avaliar a QS dos tratamentos nas duas áreas experimentais. Os níveis mais elevados de QS foram alcançados nos tratamentos com plantio direto e consórcio de gramíneas e leguminosas tropicais, devido à cobertura do solo e às elevadas adições de C e N via resíduos culturais.The soil quality (SQ evaluation is an important part of agricultural planning. It allows the identification and improvement of high-yielding management systems with characteristics of environment preservation. This study was carried out in two long-term soil management experiments (10 and 15 years in Rio Grande do Sul State, Brazil. The main objective of this study was to evaluate the effectiveness of the Soil Quality Kit (SQK developed by the Soil Quality Institute - ARS - USDA, compared to traditional soil science methods. Twelve treatments of cropping and tillage systems in a range of different tillage intensities, biomass input amounts and urea-N fertilization (0 to 144 kg ha-1 were evaluated. A native vegetation field close to each experimental area was sampled as reference treatment. The following SQ indicators: water infiltration, soil respiration, soil density, N-NO3- + N-NO2-, water aggregate stability and pH were evaluated. The correlation between the SQK and soil science methods was generally high. The highest correlation was observed with pH (r = 0.98 and the lowest for infiltration (r = 0.42. The soil management treatments were theoretically classified by crescent SQ order. The carbon pool index (CPI was obtained dividing soil organic carbon stock of each treatment by native vegetation soil organic carbon 0 to 5 cm deep. The CPI reproduces the SQ classification efficiently. Aggregate stability, soil respiration and N-NO3- + N-NO2- were the most efficient indicators at discriminating SQ. The Soil Quality Test Kit was an efficient tool to evaluate the soil quality in

  19. School-based diagnosis and treatment of malaria by teachers using rapid diagnostic tests and artemisinin-based combination therapy: experiences and perceptions of users and implementers of the Learner Treatment Kit, southern Malawi.

    Science.gov (United States)

    Mphwatiwa, Treza; Witek-McManus, Stefan; Mtali, Austin; Okello, George; Nguluwe, Paul; Chatsika, Hard; Roschnik, Natalie; Halliday, Katherine E; Brooker, Simon J; Mathanga, Don P

    2017-08-07

    Training teachers to diagnose uncomplicated malaria using malaria rapid diagnostic tests and treat with artemisinin-based combination therapy has the potential to improve the access of primary school children (6-14 years) to prompt and efficient treatment for malaria, but little is known about the acceptability of such an intervention. This qualitative study explored experiences and perceptions of users and implementers of a programme of school-based malaria case management via a first-aid kit-the Learner Treatment Kit (LTK)-implemented as part of a cluster-randomized controlled trial in Zomba district, Malawi. From 29 primary schools where teachers were trained to test and treat school children for malaria using the LTK, six schools were purposively selected on the basis of relative intervention usage (low, medium or high); school size and geographical location. In total eight focus group discussions were held with school children, parents and guardians, and teachers; and 20 in-depth interviews were conducted with key stakeholders at the school, district and national levels. Interviews were recorded, transcribed, and analysed using a thematic analysis approach. The LTK was widely perceived by respondents to be a worthwhile intervention, with the opinion that trained teachers were trusted providers of malaria testing and treatment to school children. Benefits of the programme included a perception of improved access to malaria treatment for school children; decreased school absenteeism; and that the programme supported broader national health and education policies. Potential barriers to successful implementation expressed included increased teacher workloads, a feeling of inadequate supervision from health workers, lack of incentives and concerns for the sustainability of the programme regarding the supply of drugs and commodities. Training teachers to test for and treat uncomplicated malaria in schools was well received by both users and implementers alike, and

  20. Do Men and Women Need to Be Screened Differently with Fecal Immunochemical Testing? A Cost-Effectiveness Analysis.

    Science.gov (United States)

    Meulen, Miriam P van der; Kapidzic, Atija; Leerdam, Monique E van; van der Steen, Alex; Kuipers, Ernst J; Spaander, Manon C W; de Koning, Harry J; Hol, Lieke; Lansdorp-Vogelaar, Iris

    2017-08-01

    Background: Several studies suggest that test characteristics for the fecal immunochemical test (FIT) differ by gender, triggering a debate on whether men and women should be screened differently. We used the microsimulation model MISCAN-Colon to evaluate whether screening stratified by gender is cost-effective. Methods: We estimated gender-specific FIT characteristics based on first-round positivity and detection rates observed in a FIT screening pilot (CORERO-1). Subsequently, we used the model to estimate harms, benefits, and costs of 480 gender-specific FIT screening strategies and compared them with uniform screening. Results: Biennial FIT screening from ages 50 to 75 was less effective in women than men [35.7 vs. 49.0 quality-adjusted life years (QALY) gained, respectively] at higher costs (€42,161 vs. -€5,471, respectively). However, the incremental QALYs gained and costs of annual screening compared with biennial screening were more similar for both genders (8.7 QALYs gained and €26,394 for women vs. 6.7 QALYs gained and €20,863 for men). Considering all evaluated screening strategies, optimal gender-based screening yielded at most 7% more QALYs gained than optimal uniform screening and even resulted in equal costs and QALYs gained from a willingness-to-pay threshold of €1,300. Conclusions: FIT screening is less effective in women, but the incremental cost-effectiveness is similar in men and women. Consequently, screening stratified by gender is not more cost-effective than uniform FIT screening. Impact: Our conclusions support the current policy of uniform FIT screening. Cancer Epidemiol Biomarkers Prev; 26(8); 1328-36. ©2017 AACR . ©2017 American Association for Cancer Research.

  1. A comparison of hamstring muscle activity during different screening tests for non-contact ACL injury.

    Science.gov (United States)

    Husted, Rasmus S; Bencke, Jesper; Andersen, Lars L; Myklebust, Grethe; Kallemose, Thomas; Lauridsen, Hanne B; Hölmich, Per; Aagaard, Per; Zebis, Mette K

    2016-06-01

    Reduced ability to activate the medial hamstring muscles during a sports-specific sidecutting movement has been found to be a potential risk factor for non-contact ACL injury. However, whether a reduced ability to activate the medial hamstring muscle is a general neuromuscular phenomenon and thereby observable independently of the type of clinical screening tests used is not known. This cross sectional study investigated the rank correlation of knee joint neuromuscular activity between three different ACL injury risk screening tests. Sixty-two adolescent female elite football and handball players (16.7±1.3years) participated in the study. Using surface electromyography (EMG) assessment, the neuromuscular activity of medial hamstring muscle (semitendinosus, ST), lateral hamstring muscle (biceps femoris, BF) and quadriceps muscle (vastus lateralis, VL) were monitored during three standardized screening tests - i.e. one-legged horizontal hop (OLH), drop vertical jump (DJ) and sidecutting (SC). Neuromuscular pre-activity was measured in the time interval 10ms prior to initial contact on a force plate. For neuromuscular hamstring muscle pre-activity, correlation analysis (Spearman correlation coefficient) showed low-to-moderate correlations between SC and 1) DJ (rs=0.34-0.36, Phamstring pre-activity share some common variance during the examined tests. However, a lack of strong correlation suggests that we cannot generalize one risk factor during one test to another test. The present data demonstrate that one-legged horizontal hop and drop vertical jump testing that are commonly used in the clinical setting does not resemble the specific neuromuscular activity patterns known to exist during sidecutting, a well known high risk movement for non-contact ACL injury. Copyright © 2016 Elsevier B.V. All rights reserved.

  2. Screening for cognitive impairment in older individuals. Validation study of a computer-based test.

    Science.gov (United States)

    Green, R C; Green, J; Harrison, J M; Kutner, M H

    1994-08-01

    This study examined the validity of a computer-based cognitive test that was recently designed to screen the elderly for cognitive impairment. Criterion-related validity was examined by comparing test scores of impaired patients and normal control subjects. Construct-related validity was computed through correlations between computer-based subtests and related conventional neuropsychological subtests. University center for memory disorders. Fifty-two patients with mild cognitive impairment by strict clinical criteria and 50 unimpaired, age- and education-matched control subjects. Control subjects were rigorously screened by neurological, neuropsychological, imaging, and electrophysiological criteria to identify and exclude individuals with occult abnormalities. Using a cut-off total score of 126, this computer-based instrument had a sensitivity of 0.83 and a specificity of 0.96. Using a prevalence estimate of 10%, predictive values, positive and negative, were 0.70 and 0.96, respectively. Computer-based subtests correlated significantly with conventional neuropsychological tests measuring similar cognitive domains. Thirteen (17.8%) of 73 volunteers with normal medical histories were excluded from the control group, with unsuspected abnormalities on standard neuropsychological tests, electroencephalograms, or magnetic resonance imaging scans. Computer-based testing is a valid screening methodology for the detection of mild cognitive impairment in the elderly, although this particular test has important limitations. Broader applications of computer-based testing will require extensive population-based validation. Future studies should recognize that normal control subjects without a history of disease who are typically used in validation studies may have a high incidence of unsuspected abnormalities on neurodiagnostic studies.

  3. Patient experience of CT colonography and colonoscopy after fecal occult blood test in a national screening programme

    OpenAIRE

    Plumb, Andrew A.; Ghanouni, Alex; Rees, Colin J.; Hewitson, Paul; Nickerson, Claire; Wright, Suzanne; Taylor, Stuart A.; Halligan, Steve; von Wagner, Christian

    2016-01-01

    Objective To investigate patient experience of CT colonography (CTC) and colonoscopy in a national screening programme. Methods Retrospective analysis of patient experience postal questionnaires. We included screenees from a fecal occult blood test (FOBt) based screening programme, where CTC was performed when colonoscopy was incomplete or deemed unsuitable. We analyzed questionnaire responses concerning communication of test risks, test-related discomfort and post-test pain, as well as compl...

  4. Patient experience of CT colonography and colonoscopy after fecal occult blood test in a national screening programme

    OpenAIRE

    Plumb, A. A.; Ghanouni, A.; Rees, C. J.; Hewitson, P.; Nickerson, C.; Wright, S.; Taylor, S. A.; Halligan, S.; von Wagner, C.

    2017-01-01

    OBJECTIVE: To investigate patient experience of CT colonography (CTC) and colonoscopy in a national screening programme. METHODS: Retrospective analysis of patient experience postal questionnaires. We included screenees from a fecal occult blood test (FOBt) based screening programme, where CTC was performed when colonoscopy was incomplete or deemed unsuitable. We analyzed questionnaire responses concerning communication of test risks, test-related discomfort and post-test pain, as well as com...

  5. Transmission of Hepatitis C Virus From Organ Donors Despite Nucleic Acid Test Screening.

    Science.gov (United States)

    Suryaprasad, A; Basavaraju, S V; Hocevar, S N; Theodoropoulos, N; Zuckerman, R A; Hayden, T; Forbi, J C; Pegues, D; Levine, M; Martin, S I; Kuehnert, M J; Blumberg, E A

    2015-07-01

    Nucleic acid testing (NAT) for hepatitis C virus (HCV) is recommended for screening of organ donors, yet not all donor infections may be detected. We describe three US clusters of HCV transmission from donors at increased risk for HCV infection. Donor's and recipients' medical records were reviewed. Newly infected recipients were interviewed. Donor-derived HCV infection was considered when infection was newly detected after transplantation in recipients of organs from increased risk donors. Stored donor sera and tissue samples were tested for HCV RNA with high-sensitivity quantitative PCR. Posttransplant and pretransplant recipient sera were tested for HCV RNA. Quasispecies analysis of hypervariable region-1 was used to establish genetic relatedness of recipient HCV variants. Each donor had evidence of injection drug use preceding death. Of 12 recipients, 8 were HCV-infected-6 were newly diagnosed posttransplant. HCV RNA was retrospectively detected in stored samples from donor immunologic tissue collected at organ procurement. Phylogenetic analysis showed two clusters of closely related HCV variants from recipients. These investigations identified the first known HCV transmissions from increased risk organ donors with negative NAT screening, indicating very recent donor infection. Recipient informed consent and posttransplant screening for blood-borne pathogens are essential when considering increased risk donors. © Copyright 2015 The American Society of Transplantation and the American Society of Transplant Surgeons.

  6. Terrestrial avoidance behaviour tests as screening tool to assess soil contamination

    International Nuclear Information System (INIS)

    Loureiro, Susana; Soares, Amadeu M.V.M.; Nogueira, Antonio J.A.

    2005-01-01

    To assess soil quality and risk assessment, bioassays can be useful tools to gauge the potential toxicity of contaminants focusing on their bioavailable fraction. A rapid and sublethal avoidance behaviour test was used as a screening tool with the earthworm Eisenia andrei and the isopod Porcellionides pruinosus, where organisms were exposed during 48 h to several chemicals (lindane, dimethoate and copper sulphate, for isopods and carbendazim, benomyl, dimethoate and copper sulphate for earthworms). Both species were also exposed to soils from an abandoned mine. For all bioassays a statistical approach was used to derive EC 50 values. Isopods and earthworms were able to perceive the presence of toxic compounds and escaping from contaminated to clean soil. Furthermore the behaviour parameter was equally or more sensitive then other sublethal parameters (e.g. reproduction or growth), expressing the advantages of Avoidance Behaviour Tests as screening tools in ERA. - Avoidance Behaviour Tests with earthworms and isopods can be used as screening tools in the evaluation of soil contamination

  7. Changes in screening behaviors and attitudes toward screening from pre-test genetic counseling to post-disclosure in Lynch syndrome families

    Science.gov (United States)

    Burton-Chase, Allison M.; Hovick, Shelly R.; Peterson, Susan K.; Marani, Salma K.; Vernon, Sally W.; Amos, Christopher I.; Frazier, Marsha L.; Lynch, Patrick M.; Gritz, Ellen R.

    2013-01-01

    Purpose This study examined colonoscopy adherence and attitudes towards colorectal cancer (CRC) screening in individuals who underwent Lynch syndrome genetic counseling and testing. Methods We evaluated changes in colonoscopy adherence and CRC screening attitudes in 78 cancer-unaffected relatives of Lynch syndrome mutation carriers before pre-test genetic counseling (baseline) and at 6 and 12 months post-disclosure of test results (52 mutation-negative, 26 mutation-positive). Results While both groups were similar at baseline, at 12 months post-disclosure, a greater number of mutation-positive individuals had had a colonoscopy compared with mutation-negative individuals. From baseline to 12 months post-disclosure, the mutation-positive group demonstrated an increase in mean scores on measures of colonoscopy commitment, self-efficacy, and perceived benefits of CRC screening, and a decrease in mean scores for perceived barriers to CRC screening. Mean scores on colonoscopy commitment decreased from baseline to 6 months in the mutation-negative group. Conclusion Adherence to risk-appropriate guidelines for CRC surveillance improved after genetic counseling and testing for Lynch syndrome. Mutation-positive individuals reported increasingly positive attitudes toward CRC screening after receiving genetic test results, potentially reinforcing longer term colonoscopy adherence. PMID:23414081

  8. Complex Approach to Thyroid Screening In Regions Adjacent to the Semipalatinsk Test Site Area

    International Nuclear Information System (INIS)

    Zhumadilov, Zh.Sh.; Musinov, D.R.; Vasikovsky, G.G.; Bobokhidze, D.A.; Zhigitaev, T.K.; Abisheva, G.N.

    1998-01-01

    It has been well documented that the thyroid gland is one of the most radiosensitive of organs, especially when exposure occurs during childhood. It is known as well that childhood exposure to radioactive iodine increases thyroid cancer risk. Conducting thyroid screening in regions adjacent to the Semipalatinsk Test Site (STS) area is very important for medical examination, data management and thyroid dose reconstruction. Our experience of thyroid screening based on our screening projects in Kurchatov and several regions adjacent to STS (more than 4,000 screened patients) allowed to work out the most appropriate screening protocol. A retrospective analysis of the results of surgical treatment of the 7,271 patients with thyroid abnormalities in the Semipalatinsk, Pavlodar and Ust-Kamenogorsk regions of Kazakstan and study the histological staging of 7,271 surgically removed thyroid glands was preceded by our thyroid screening projects. Ours is the first study in the Semipalatinsk region that covers the period 1966-1998.Taking into account the onset of population effective doses during 1962, it was decided to distinguish 6 periods of observation. It is known that basic effective equivalent doses for the majority of the region's population were established by radioactive events in the period 1949-1962. This explains our focus on the year 1962, but thyroid dose reconstruction matter as well as other radiation related problems are still in the progress. We need to get the accurate dosimetry data. Selection of study subjects based on the appropriate criteria needed to be adjusted and clarified in accordance with the main goal of the project and radiation related information. All specialists involved in the thyroid screening project, data management, data analyses and interpretation of the results must be trained and must be highly qualified specialists in this field of science and practice. The experiences in Nagasaki, Hiroshima and Chernobyl, and discussions with

  9. The King-Devick test for sideline concussion screening in collegiate football.

    Science.gov (United States)

    Leong, Danielle F; Balcer, Laura J; Galetta, Steven L; Evans, Greg; Gimre, Matthew; Watt, David

    2015-01-01

    Sports-related concussion has received increasing attention as a result of neurologic sequelae seen among athletes, highlighting the need for a validated, rapid screening tool. The King-Devick (K-D) test requires vision, eye movements, language function and attention in order to perform and has been proposed as a promising tool for assessment of concussion. We investigated the K-D test as a sideline screening tool in a collegiate cohort to determine the effect of concussion. Athletes (n=127, mean age 19.6±1.2 years) from the Wheaton College football and men's and women's basketball teams underwent baseline K-D testing at pre-season physicals for the 2012-2013 season. K-D testing was administered immediately on the sidelines for football players with suspected head injury during regular games and changes compared to baseline were determined. Post-season testing was also performed to compare non-concussed athletes' test performance. Concussed athletes (n=11) displayed sideline K-D scores that were significantly higher (worse) than baseline (36.5±5.6s vs. 31.3±4.5s, pWilcoxon signed-rank test). Post-season testing demonstrated improvement of scores and was consistent with known learning effects (35.1±5.2s vs. 34.4±5.0s, pWilcoxon signed-rank test). Test-retest reliability was analyzed between baseline and post-season administrations of the K-D test resulting in high levels of test-retest reliability (intraclass correlation coefficient (ICC)=0.95 [95% Confidence Interval 0.85-1.05]). The data show worsening of K-D test scores following concussion further supporting utility of the K-D test as an objective, reliable and effective sideline visual screening tool to help identify athletes with concussion. Copyright © 2014 Spanish General Council of Optometry. Published by Elsevier Espana. All rights reserved.

  10. 10 CFR Appendix V to Subpart B of... - Uniform Test Method for Measuring the Energy Consumption of Ceiling Fan Light Kits

    Science.gov (United States)

    2010-01-01

    ... 10 Energy 3 2010-01-01 2010-01-01 false Uniform Test Method for Measuring the Energy Consumption... Appendix V to Subpart B of Part 430—Uniform Test Method for Measuring the Energy Consumption of Ceiling Fan... the final energy consumption value to a whole number as follows: (i) A fractional number at or above...

  11. Comparative evaluation of the CerTest VIASURE flu A, B & RSV real time RT-PCR detection kit on the BD MAX system versus a routine in-house assay for detection of influenza A and B virus during the 2016/17 influenza season

    DEFF Research Database (Denmark)

    Sydenham, Thomas Vognbjerg; Bek-Thomsen, Malene; Andersen, Signe Dalsgaard

    2018-01-01

    laboratory technician "hands on" time but also the laboratory turnaround time is of interest. OBJECTIVES: We evaluated the performance of the VIASURE Flu A, B & RSV Real Time RT-PCR Detection Kit (CerTest Biotec) for detecting Influenza A and B viruses. STUDY DESIGN: During the 2016/17 influenza season 532...

  12. Screening for cognitive dysfunction in Huntington's disease with the clock drawing test.

    Science.gov (United States)

    Terwindt, Paul W; Hubers, Anna A M; Giltay, Erik J; van der Mast, Rose C; van Duijn, Erik

    2016-09-01

    The aim of the study is to investigate the performance of the clock drawing test as a screening tool for cognitive impairment in Huntington's disease (HD) mutation carriers. The performance of the clock drawing test was assessed in 65 mutation carriers using the Shulman and the Freund scoring systems. The mini-mental state examination, the Symbol Digit Modalities Test, the Verbal Fluency Test, and the Stroop tests were used as comparisons for the evaluation of cognitive functioning. Correlations of the clock drawing test with various cognitive tests (convergent validity), neuropsychiatric characteristics (divergent validity) and clinical characteristics were analysed using the Spearman's rank correlation coefficient. Receiver-operator characteristic analyses were performed for the clock drawing test against both the mini-mental state examination and against a composite variable for executive cognitive functioning to assess optimal cut-off scores. Inter-rater reliability was high for both the Shulman and Freund scoring systems (ICC = 0.95 and ICC = 0.90 respectively). The clock drawing tests showed moderate to high correlations with the composite variable for executive cognitive functioning (mean ρ = 0.75) and weaker correlations with the mini-mental state examination (mean ρ = 0.62). Mean sensitivity of the clock drawing tests was 0.82 and mean specificity was 0.79, whereas the mean positive predictive value was 0.66 and the mean negative predictive value was 0.87. The clock drawing test is a suitable screening instrument for cognitive dysfunction in HD, because it was shown to be accurate, particularly so with respect to executive cognitive functioning, and is easy and quick to use. Copyright © 2016 John Wiley & Sons, Ltd. Copyright © 2016 John Wiley & Sons, Ltd.

  13. Implementation of broad screening with Ebola rapid diagnostic tests in Forécariah, Guinea

    Directory of Open Access Journals (Sweden)

    Frantz Jean Louis

    2017-03-01

    Full Text Available Background: Laboratory-enhanced surveillance is critical for rapidly detecting the potential re-emergence of Ebola virus disease. Rapid diagnostic tests (RDT for Ebola antigens could expand diagnostic capacity for Ebola virus disease. Objectives: The Guinean National Coordination for Ebola Response conducted a pilot implementation to determine the feasibility of broad screening of patients and corpses with the OraQuick® Ebola RDT. Methods: The implementation team developed protocols and trained healthcare workers to screen patients and corpses in Forécariah prefecture, Guinea, from 15 October to 30 November 2015. Data collected included number of consultations, number of fevers reported or measured, number of tests performed for patients or corpses and results of confirmatory RT-PCR testing. Data on malaria RDT results were collected for comparison. Feedback from Ebola RDT users was collected informally during supervision visits and forums. Results: There were 3738 consultations at the 15 selected healthcare facilities; 74.6% of consultations were for febrile illness. Among 2787 eligible febrile patients, 2633 were tested for malaria and 1628 OraQuick® Ebola RDTs were performed. A total of 322 OraQuick® Ebola RDTs were conducted on corpses. All Ebola tests on eligible patients were negative. Conclusions: Access to Ebola testing was expanded by the implementation of RDTs in an emergency situation. Feedback from Ebola RDT users and lessons learned will contribute to improving quality for RDT expansion.

  14. The Addenbrooke's Cognitive Examination Revised as a potential screening test for elderly drivers.

    Science.gov (United States)

    Ferreira, Inês S; Simões, Mário R; Marôco, João

    2012-11-01

    Considerable research has shown that neuropsychological tests are predictive of real-world driving ability. The Mini-Mental State Examination (MMSE) is a brief cognitive test that has been commonly used in the assessment of older drivers. However, this test has inherent problems that limit its validity to evaluate cognitive abilities related to driving and to screen for driving impairments in non-demented people. Therefore, it is useful to test new screening instruments that may predict potential unsafe drivers who require an in-depth neuropsychological assessment in a specialised centre. To date, the utility of the Addenbrooke's Cognitive Examination Revised (ACE-R) as an indicator of driving ability has not been established. In the current study, fifty older drivers (mean age=73.1 years) who were referred for a psychological assessment, the protocol of which included the ACE-R, underwent an on-road driving test. Using linear discriminant analyses, the results highlighted the higher classification accuracy of the ACE-R compared to the MMSE score, particularly for detecting unsafe drivers. Measures of visuospatial and executive functions, which are not incorporated in the MMSE score, had an incremental value in the prediction of driving ability. This emerging brief cognitive test may warrant additional study for use in the fitness to drive assessment of older adults. Copyright © 2012 Elsevier Ltd. All rights reserved.

  15. Preparation of albumin radioimmunoassay kit

    International Nuclear Information System (INIS)

    Chen Suoshu; Wang Yanzhen; Wang Zhenshan

    1990-01-01

    This paper presents the preparation of Albumin (Alb) radioimmunoassay kit and its preliminary clinical application. The kit is mainly applied to the measurement of Alb concentration in human urine, adopting second antibody-PEG method. The measurement range is (1-50 μg/ml). The curve obtained with a serially diluted urine sample of high Alb concentration was a straight line. Recovery, detectability, intra- and inter-batch variation coefficients were 95.7%-103.6%, 0.1 μg/ml, 5.8% and 6.4% respectively. The kit was tried out clinically for measuring Alb in urine samples in about 1200 normal individuals and 600 various patients of related renal diseases. The preliminary clinical results show that Alb RIA is conducive to the early diagnosis of kidney function abnormalities

  16. Applicability of Screening Tests for Oxytetracycline in the Milk of Three Breeds of Goats.

    Science.gov (United States)

    Attaie, Rahmat; Bsharat, Mohammed; Mora-Gutierrez, Adela

    2016-06-01

    Antibiotics are widely used in animal husbandry, and the presence of antibiotic residues in milk is a health hazard. The objectives of this study were to determine residual amounts of oxytetracycline in the milk of three breeds of goats using high-pressure liquid chromatography (HPLC) analysis and screening tests. It was also essential to explore the safe withdrawal period of oxytetracycline in lactating goats and examine the applicability of Charm ROSA and SNAP screening tests. The qualitative results of these tests were compared with the quantitative results of the HPLC method. Fifteen milking does, five each from the Alpine, LaMancha, and Nubian breeds, were selected from the herd at Prairie View A&M University. Milk samples containing antibiotic residues were deproteinized by HCl and acetonitrile, and then oxytetracycline was extracted from the supernatant. The residues of oxytetracycline in goat's milk up to 110 h after injection were qualitatively detected using the Charm ROSA test. Similarly, the SNAP test detected the antibiotic residues in milk up to 110 h after treatment. The HPLC results indicated that oxytetracycline residues in milk from Alpine goats were below the tolerance level (300 ng/ml) 82 h after drug treatment (72 h for LaManchas, 58 h for Nubians); however, the results of the screening tests would indicate longer withdrawal periods for milk from the breeds of goats studied, which would result in economic losses to goat's milk producers. The results of this study also indicated that oxytetracycline was not stable in raw goat's milk at refrigeration temperature or during pasteurization and that the concentrations decreased significantly. Commercial goat's milk is usually exposed to several hours of refrigeration and then to pasteurization. The results of this study indicated that, if oxytetracycline was present in raw goat's milk, the concentration would decrease significantly before it was marketed.

  17. Use of external metabolizing systems when testing for endocrine disruption in the T-screen assay

    International Nuclear Information System (INIS)

    Taxvig, Camilla; Olesen, Pelle Thonning; Nellemann, Christine

    2011-01-01

    Although, it is well-established that information on the metabolism of a substance is important in the evaluation of its toxic potential, there is limited experience with incorporating metabolic aspects into in vitro tests for endocrine disrupters. The aim of the current study was a) to study different in vitro systems for biotransformation of ten known endocrine disrupting chemicals (EDs): five azole fungicides, three parabens and 2 phthalates, b) to determine possible changes in the ability of the EDs to bind and activate the thyroid receptor (TR) in the in vitro T-screen assay after biotransformation and c) to investigate the endogenous metabolic capacity of the GH3 cells, the cell line used in the T-screen assay, which is a proliferation assay used for the in vitro detection of agonistic and antagonistic properties of compounds at the level of the TR. The two in vitro metabolizing systems tested the human liver S9 mix and the PCB-induced rat microsomes gave an almost complete metabolic transformation of the tested parabens and phthalates. No marked difference the effects in the T-screen assay was observed between the parent compounds and the effects of the tested metabolic extracts. The GH3 cells themselves significantly metabolized the two tested phthalates dimethyl phthalate (DMP) and diethyl phthalate (DEP). Overall the results and qualitative data from the current study show that an in vitro metabolizing system using liver S9 or microsomes could be a convenient method for the incorporation of metabolic and toxicokinetic aspects into in vitro testing for endocrine disrupting effects.

  18. Evaluation of the Lumipulse G TP-N Chemiluminescent Immunoassay as a Syphilis Screening Test.

    Science.gov (United States)

    Ortiz, Daniel A; Loeffelholz, Michael J

    2017-11-01

    A syphilis diagnosis is often aided by the detection of treponemal and nontreponemal antibodies. Automated treponemal antibody detection systems enable high-volume clinical laboratories to perform syphilis screening at a faster pace with lower labor costs. The Lumipulse G TP-N chemiluminescent immunoassay is an automated system that qualitatively detects IgG and IgM antibodies against Treponema pallidum antigens in human serum and plasma. To assess performance characteristics and workflow efficiency, the Lumipulse G TP-N assay was compared to the Bioplex 2200 Syphilis IgG multiplex flow immunoassay. Among the 4,134 routine and HIV samples tested by the two automated assays, the percentage of agreement was excellent at 99.0% (95% confidence interval [CI], 98.6% to 99.2%; κ, 0.89), with the Lumipulse G TP-N having a shorter time to first and subsequent results. All specimens with reactive syphilis screening results were further tested by rapid plasma reagin (RPR) and Treponema pallidum particle agglutination (TP·PA) testing ( n = 231). The results from the RPR-reactive samples ( n = 82) showed complete concordance with the two automated assays, while the TP·PA assay displayed some discrepancies. The positive percent agreement (PPA) and negative percent agreement (NPA) between the TP·PA test and the Lumipulse G TP-N test were 98.9% and 77.3%, respectively. The Bioplex 2200 Syphilis IgG immunoassay displayed a similar PPA (100%) but a substantially lower NPA (15.9%). Patient chart reviews of discrepant results suggested that the Lumipulse G TP-N assay produced 27 fewer falsely reactive results and can reduce the amount of additional confirmatory RPR and TP·PA testing needed. The analogous performance characteristics of the two automated systems indicate that the Lumipulse G TP-N assay is suitable for high-throughput syphilis screening. Copyright © 2017 American Society for Microbiology.

  19. Development of the Thai version of Mini-Cog, a brief cognitive screening test.

    Science.gov (United States)

    Trongsakul, Supaporn; Lambert, Rod; Clark, Allan; Wongpakaran, Nahathai; Cross, Jane

    2015-05-01

    Cognitive impairment, such as dementia, has emerged as the leading public health problem among the elderly. Therefore, early detection of the disorder and providing appropriate healthcare and management is important, particularly, for the patients with comorbid diabetes who require long-term treatment strategies. In Thailand, because of a large number of elderly patients with diabetes, and time constraints in primary care settings, a short and effective cognitive screening test is required. The Mini-Cog is a short and valid cognitive screening test that was specifically designed for use in primary care settings. The present study translated the English language version into a Thai language version, and then measured the interrater reliability and concurrent validity. The processes of cross-language translation were carried out to develop a Thai language version of the Mini-Cog. A total of 21 Thai older adults with type 2 diabetes with a mean aged of 69 ± 7 years were recruited into a study investigating the interrater reliability and concurrent validity of the Mini-Cog Thai version in one primary care center in Thailand. The Mini-Cog Thai version showed a good interrater reliability (K = 0.80, P validity (r = 0.47, P = 0.007, 95% CI 0.37,0.55) with the Mini-Mental State Examination Thai 2002. The findings show that the Thai version of the Mini-Cog is a reliable, performance-based tool in the screening for cognitive function in primary care settings in Thailand. It is recommended that it could be used as a new cognitive screening test for the aging population in the Thai community. © 2014 Japan Geriatrics Society.

  20. Testing the woman abuse screening tool to identify intimate partner violence in Indonesia.

    Science.gov (United States)

    Iskandar, Livia; Braun, Kathryn L; Katz, Alan R

    2015-04-01

    Intimate Partner Violence (IPV) is a global public health problem. IPV prevalence in Indonesia has been estimated to be less than 1%, based on reported cases. It is likely that IPV prevalence is underreported in Indonesia, as it is in many other countries. Screening for IPV has been found to increase IPV identification, but no screening tools are in use in Indonesia. The aim of this study was to test the translated Woman Abuse Screening Tool (WAST) for detecting IPV in Indonesia. The WAST was tested against a diagnostic interview by a trained psychologist on 240 women attending two Primary Health Centers in Jakarta. IPV prevalence and the reliability, sensitivity, and specificity of the WAST were estimated. Prevalence of IPV by diagnostic interview was 36.3%, much higher than published estimates. The most common forms of IPV identified were psychological (85%) and physical abuse (24%). Internal reliability of the WAST was high (α = .801). A WAST score of 13 (out of 24) is the recommended cutoff for identifying IPV, but only 17% of the Indonesian sample scored 13 or higher. Test sensitivity of the WAST with a cutoff score of 13 was only 41.9%, with a specificity of 96.8%. With a cutoff score of 10, the sensitivity improved to 84.9%, while the specificity decreased to 61.0%. Use of the WAST with a cutoff score of 10 provides good sensitivity and reasonable specificity and would provide a much-needed screening tool for use in Indonesia. Although a lower cutoff would yield a greater proportion of false positives, most of the true cases would be identified, increasing the possibility that women experiencing abuse would receive needed assistance. © The Author(s) 2014.

  1. The minimum test battery to screen for binocular vision anomalies: report 3 of the BAND study.

    Science.gov (United States)

    Hussaindeen, Jameel Rizwana; Rakshit, Archayeeta; Singh, Neeraj Kumar; Swaminathan, Meenakshi; George, Ronnie; Kapur, Suman; Scheiman, Mitchell; Ramani, Krishna Kumar

    2018-03-01

    This study aims to report the minimum test battery needed to screen non-strabismic binocular vision anomalies (NSBVAs) in a community set-up. When large numbers are to be screened we aim to identify the most useful test battery when there is no opportunity for a more comprehensive and time-consuming clinical examination. The prevalence estimates and normative data for binocular vision parameters were estimated from the Binocular Vision Anomalies and Normative Data (BAND) study, following which cut-off estimates and receiver operating characteristic curves to identify the minimum test battery have been plotted. In the receiver operating characteristic phase of the study, children between nine and 17 years of age were screened in two schools in the rural arm using the minimum test battery, and the prevalence estimates with the minimum test battery were found. Receiver operating characteristic analyses revealed that near point of convergence with penlight and red filter (> 7.5 cm), monocular accommodative facility ( 1.25 prism dioptres) were significant factors with cut-off values for best sensitivity and specificity. This minimum test battery was applied to a cohort of 305 children. The mean (standard deviation) age of the subjects was 12.7 (two) years with 121 males and 184 females. Using the minimum battery of tests obtained through the receiver operating characteristic analyses, the prevalence of NSBVAs was found to be 26 per cent. Near point of convergence with penlight and red filter > 10 cm was found to have the highest sensitivity (80 per cent) and specificity (73 per cent) for the diagnosis of convergence insufficiency. For the diagnosis of accommodative infacility, monocular accommodative facility with a cut-off of less than seven cycles per minute was the best predictor for screening (92 per cent sensitivity and 90 per cent specificity). The minimum test battery of near point of convergence with penlight and red filter, difference between distance and near

  2. Usefulness of CA 130 kit based on IRMA

    International Nuclear Information System (INIS)

    Fujii, Takashi; Kimura, Yoshiko; Ata, Mariko; Miyagawa, Naoko; Iio, Atsushi; Hamamoto, Ken

    1988-01-01

    Immunoradiometric assay for CA 130 was fundamentally and clinically evaluated using a commercially available D-7111 kit. Incubation time was 4 hr with the present CA 133 kit as compared with 16 - 24 hr with conventional CA 125 kit. Laboratory performance of CA 130 kit was satisfactory for standard curve, reproducibility, and recovery test. There was well correlation between the present CA 130 kit and CA 125 kit (r = 0.931). The concentration of CA 130 in the serum was significantly higher in healthy women than men (17.3 +- 10.5 U/ml vs 9.6 +- 5.1 U/ml). Serum CA 130 levels tended to decrease with aging, regardless of sex. These levels were changeable with menstrual cycle ; i.e., these were significantly higher during menstrual phase (24.2 +- 9.0 U/ml) and significantly lower during ovulatory phase (10.9 +- 2.4 U/ml) and during menopause (12.1 +- 3.4 U/ml). Cut off serum CA 130 levels were defined as 20 U/ml for men and 38 U/ml for women. Positive rate for CA 130 was the highest in cases of ovarian cancer (80 %), followed by endometrial cancer (50 %), pancreatic cancer (47 %), benign ovarian tumor (44 %), and lung cancer (39 %). (Namekawa, K.)

  3. A European multicientre study on the comparison of HBV viral loads between VERIS HBV assay and Roche COBAS® TAQMAN® HBV test, Abbott RealTime HBV assay, Siemens VERSANT HBV assay, and Qiagen artus HBV RG kit.

    Science.gov (United States)

    Braun, Patrick; Delgado, Rafael; Drago, Monica; Fanti, Diana; Fleury, Hervé; Izopet, Jacques; Lombardi, Alessandra; Marcos, MaAngeles; Sauné, Karine; O'Shea, Siobhan; Pérez-Rivilla, Alfredo; Ramble, John; Trimoulet, Pascale; Vila, Jordi; Whittaker, Duncan; Artus, Alain; Rhodes, Daniel

    2017-10-01

    Hepatitis B viral load testing is essential to treatment and monitoring decisions in patients with chronic Hepatitis B. Beckman Coulter has developed the VERIS HBV Assay (Veris) for use on the fully automated DxN VERIS Molecular Diagnostics System. 1 OBJECTIVES: To evaluate the clinical performance of the Veris HBV Assay at multiple EU laboratories STUDY DESIGN: Method comparison was performed with a total of 344 plasma specimens from HBV infected patients tested with Veris and COBAS ® TaqMan ® HBV Test (Cobas), 207 specimens tested with Veris and RealTime HBV Assay (RealTime), 86 specimens tested with Veris and VERSANT ® HBV Assay (Versant), and 74 specimens tested with Veris and artus ® HBV RG PCR kit (artus). Bland-Altman analysis showed average bias of -0.46 log 10 IU/mL between Veris and Cobas, -0.46 log 10 IU/mL between Veris and RealTime, -0.36 log 10 IU/mL between Veris and Versant, and -0.12 log 10 IU/mL between Veris and artus. Bias was consistent across the assay range. Patient monitoring results using Veris demonstrated similar viral load trends over time to Cobas, RealTime, and artus. The VERIS HBV Assay demonstrated comparable clinical performance, with varying degrees of negative bias, compared to other currently marketed assays for HBV DNA monitoring. This negative bias should be taken into consideration if switching monitoring methods to Veris. Copyright © 2017 Elsevier B.V. All rights reserved.

  4. Is the Screening Test of the French Version of the Dementia Quality of Life Questionnaire Indispensable

    Directory of Open Access Journals (Sweden)

    A. Wolak

    2011-04-01

    Full Text Available The aim of this study was to evaluate the usefulness of the screening questions in the French version of the Dementia Quality of Life (DQoL questionnaire. To assess the psychometric properties of the French DQoL, 155 patients with mild-to-moderate dementia were recruited. Here, we compared the psychometric properties of the instrument between patients who passed the screening test (n = 109 and the whole study population (n = 155. The French DQoL version showed a good test-retest reliability at a 2-week interval (0.95 ≤ intraclass correlation coefficients ≤ 1.0, and an average internal consistency (0.58 ≤ Cronbach’s α ≤ 0.87 for the 2 study groups. Significant differences were observed in the 2 groups for 4 dimensions of the DQoL regarding dementia severity (Cornell scale, and for 3 dimensions evaluating depression (MMSE. Convergent validity with the Duke Health Profile revealed many significant correlations between dimensions not only in the 109 patients, but also in the whole study population. Our study demonstrated that patients who failed the screening procedure nonetheless seemed to be able to answer the DQoL questionnaire, the whole study group showing acceptable psychometric properties.

  5. Elevated serum CA 19-9 at screening tests: underlying conditions and role of abdominopelvic CT

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Ji Yang [University of Louisville, Department of Radiology and Molecular Imaging Research Center, Louisville, KY (United States); Seoul National University Hospital, Department of Radiology, Healthcare System Gangnam Center, Seoul (Korea, Republic of); Kim, Se Hyung [Seoul National University Hospital, Department of Radiology and the Institute of Radiation Medicine, Seoul (Korea, Republic of); Kim, Soo Young [Seoul National University Hospital, Department of Radiology, Healthcare System Gangnam Center, Seoul (Korea, Republic of); Bundang CHA Hospital, Department of Radiology, Bundang (Korea, Republic of)

    2014-10-15

    To investigate underlying conditions of patients with elevated CA 19-9 at screening tests and to evaluate diagnostic performance of abdominopelvic CT. One hundred and thirteen patients with elevated CA 19-9 (>37 U/ml) who underwent abdominopelvic CT in a screening program were selected. Underlying conditions were determined by reviewing all available data and follow-up records. Patients were categorized into malignancy, benign, and normal/non-related disease groups. Their mean CA 19-9 and percent of patients with CA 19-9 ≥ 100 U/ml were compared. Diagnostic sensitivity of CT for detecting underlying conditions of elevated CA 19-9 was analysed. Seventeen patients (17/113, 15 %) had 17 elevated CA 19-9-related malignancies, and 55 patients (55/113, 48.7 %) had 70 benign diseases. Mean CA 19-9 and percent of patients with CA 19-9 ≥ 100 U/ml in the malignancy group were significantly higher than in the two other groups. CT detected all except one malignant lesion with a detection sensitivity of 94.1 % (16/17). Of 70 CA 19-9-related benign diseases, CT detected 34 benign diseases (48.6 %) providing an alternative diagnosis for elevated CA 19-9. Abdominopelvic CT is not only useful in detecting malignancies, but can also diagnose alternative benign causes of elevated CA 19-9 in asymptomatic screening tests. (orig.)

  6. Type 2 Diabetes Screening Test by Means of a Pulse Oximeter.

    Science.gov (United States)

    Moreno, Enrique Monte; Lujan, Maria Jose Anyo; Rusinol, Montse Torrres; Fernandez, Paqui Juarez; Manrique, Pilar Nunez; Trivino, Cristina Aragon; Miquel, Magda Pedrosa; Rodriguez, Marife Alvarez; Burguillos, M Jose Gonzalez

    2017-02-01

    In this paper, we propose a method for screening for the presence of type 2 diabetes by means of the signal obtained from a pulse oximeter. The screening system consists of two parts: the first analyzes the signal obtained from the pulse oximeter, and the second consists of a machine-learning module. The system consists of a front end that extracts a set of features form the pulse oximeter signal. These features are based on physiological considerations. The set of features were the input of a machine-learning algorithm that determined the class of the input sample, i.e., whether the subject had diabetes or not. The machine-learning algorithms were random forests, gradient boosting, and linear discriminant analysis as benchmark. The system was tested on a database of [Formula: see text] subjects (two samples per subject) collected from five community health centers. The mean receiver operating characteristic area found was [Formula: see text]% (median value [Formula: see text]% and range [Formula: see text]%), with a specificity =  [Formula: see text]% for a threshold that gave a sensitivity = [Formula: see text]%. We present a screening method for detecting diabetes that has a performance comparable to the glycated haemoglobin (haemoglobin A1c HbA1c) test, does not require blood extraction, and yields results in less than 5 min.

  7. Economic Evaluations of Pharmacogenetic and Pharmacogenomic Screening Tests: A Systematic Review. Second Update of the Literature.

    Directory of Open Access Journals (Sweden)

    Elizabeth J J Berm

    Full Text Available Due to extended application of pharmacogenetic and pharmacogenomic screening (PGx tests it is important to assess whether they provide good value for money. This review provides an update of the literature.A literature search was performed in PubMed and papers published between August 2010 and September 2014, investigating the cost-effectiveness of PGx screening tests, were included. Papers from 2000 until July 2010 were included via two previous systematic reviews. Studies' overall quality was assessed with the Quality of Health Economic Studies (QHES instrument.We found 38 studies, which combined with the previous 42 studies resulted in a total of 80 included studies. An average QHES score of 76 was found. Since 2010, more studies were funded by pharmaceutical companies. Most recent studies performed cost-utility analysis, univariate and probabilistic sensitivity analyses, and discussed limitations of their economic evaluations. Most studies indicated favorable cost-effectiveness. Majority of evaluations did not provide information regarding the intrinsic value of the PGx test. There were considerable differences in the costs for PGx testing. Reporting of the direction and magnitude of bias on the cost-effectiveness estimates as well as motivation for the chosen economic model and perspective were frequently missing.Application of PGx tests was mostly found to be a cost-effective or cost-saving strategy. We found that only the minority of recent pharmacoeconomic evaluations assessed the intrinsic value of the PGx tests. There was an increase in the number of studies and in the reporting of quality associated characteristics. To improve future evaluations, scenario analysis including a broad range of PGx tests costs and equal costs of comparator drugs to assess the intrinsic value of the PGx tests, are recommended. In addition, robust clinical evidence regarding PGx tests' efficacy remains of utmost importance.

  8. A virtual reality test battery for assessment and screening of spatial neglect.

    Science.gov (United States)

    Fordell, H; Bodin, K; Bucht, G; Malm, J

    2011-03-01

    There is a need for improved screening methods for spatial neglect. To construct a VR-test battery and evaluate its accuracy and usability in patients with acute stroke. VR-DiSTRO consists of a standard desktop computer, a CRT monitor and eye shutter stereoscopic glasses, a force feedback interface, and software, developed to create an interactive and immersive 3D experience. VR-tests were developed and validated to the conventional Star Cancellation test, Line bisection, Baking Tray Task (BTT), and Visual Extinction test. A construct validation to The Rivermead Behavioral Inattention Test, used as criterion of visuospatial neglect, was made. Usability was assessed according to ISO 9241-11. Thirty-one patients with stroke were included, 9/31 patients had neglect. The sensitivity was 100% and the specificity 82% for the VR-DiSTRO to correctly identify neglect. VR-BTT and VR-Extinction had the highest correlation (r² = 0.64 and 0.78), as well as high sensitivity and specificity. The kappa values describing the agreement between traditional neglect tests and the corresponding virtual reality test were between 0.47-0.85. Usability was assessed by a questionnaire; 77% reported that the VR-DiSTRO was 'easy' to use. Eighty-eight percent reported that they felt 'focused', 'pleased' or 'alert'. No patient had adverse symptoms. The test session took 15 min. The VR-DiSTRO quickly and with a high accuracy identified visuospatial neglect in patients with stroke in this construct validation. The usability among elderly patients with stroke was high. This VR-test battery has the potential to become an important screening instrument for neglect and a valuable adjunct to the neuropsychological assessment. © 2010 John Wiley & Sons A/S.

  9. Usability Testing of a National Substance Use Screening Tool Embedded in Electronic Health Records.

    Science.gov (United States)

    Press, Anne; DeStio, Catherine; McCullagh, Lauren; Kapoor, Sandeep; Morley, Jeanne; Conigliaro, Joseph

    2016-07-08

    Screening, brief intervention, and referral to treatment (SBIRT) is currently being implemented into health systems nationally via paper and electronic methods. The purpose of this study was to evaluate the integration of an electronic SBIRT tool into an existing paper-based SBIRT clinical workflow in a patient-centered medical home. Usability testing was conducted in an academic ambulatory clinic. Two rounds of usability testing were done with medical office assistants (MOAs) using a paper and electronic version of the SBIRT tool, with two and four participants, respectively. Qualitative and quantitative data was analyzed to determine the impact of both tools on clinical workflow. A second round of usability testing was done with the revised electronic version and compared with the first version. Personal workflow barriers cited in the first round of testing were that the electronic health record (EHR) tool was disruptive to patient's visits. In Round 2 of testing, MOAs reported favoring the electronic version due to improved layout and the inclusion of an alert system embedded in the EHR. For example, using the system usability scale (SUS), MOAs reported a grade "1" for the statement, "I would like to use this system frequently" during the first round of testing but a "5" during the second round of analysis. The importance of testing usability of various mediums of tools used in health care screening is highlighted by the findings of this study. In the first round of testing, the electronic tool was reported as less user friendly, being difficult to navigate, and time consuming. Many issues faced in the first generation of the tool were improved in the second generation after usability was evaluated. This study demonstrates how usability testing of an electronic SBRIT tool can help to identify challenges that can impact clinical workflow. However, a limitation of this study was the small sample size of MOAs that participated. The results may have been biased to

  10. Cone penetrometer tests and HydroPunch sampling: A screening technique for plume definition

    International Nuclear Information System (INIS)

    Smolley, M.; Kappmeyer, J.C.

    1991-01-01

    Cone penetrometer tests and HydroPunch sampling were used to define the extent of volatile organic compounds in ground water. The investigation indicated that the combination of the these techniques is effective for obtaining ground water samples for preliminary plume definition. HydroPunch samples can be collected in unconsolidated sediments and the analytical results obtained from these samples are comparable to those obtained from adjacent monitoring wells. This sampling method is a rapid and cost-effective screening technique for characterizing the extent of contaminant plumes in soft sediment environments. Use of this screening technique allowed monitoring wells to be located at the plume boundary, thereby reducing the number of wells installed and the overall cost of the plume definition program

  11. Diagnostic dilemma of the single screening test used in the diagnosis of syphilis in Nepal.

    Science.gov (United States)

    Dumre, S P; Shakya, G; Acharya, D; Malla, S; Adhikari, N

    2011-12-01

    Syphilis screening by the nontreponemal rapid plasma reagin (RPR) test is not usually followed up by specific treponemal tests in most of the resource poor healthcare settings of Nepal. We analyzed serum specimens of 504 suspected syphilis cases at the immunology department of the national reference laboratory in Nepal during 2007-2009 using RPR test and Treponema pallidum hemagglutination assay (TPHA). In overall, 35.7% were positive by both methods (combination) while 13.1% were RPR positive and TPHA negative, 8.7% were positive by TPHA only and 42.5% were negative by both methods. Among the RPR reactive (n = 246), 73.2% were positive by TPHA. Non-specific agglutination in RPR testing was relatively higher (26.8%) compared to TPHA (19.6%). Although TPHA was found more specific than RPR test, either of the single tests produced inaccurate diagnosis. Since the single RPR testing for syphilis may yield false positive results, specific treponemal test should be routinely used as confirmatory test to rule out false RPR positive cases. More attention needs to be paid on formulation of strict policy on the implementation of the existing guidelines throughout the country to prevent misdiagnosis in syphilis with the use of single RPR test.

  12. Screening health care workers with interferon-γ release assay versus tuberculin skin test: impact on costs and adherence to testing (the SWITCH study).

    Science.gov (United States)

    Wrighton-Smith, Peter; Sneed, Laurie; Humphrey, Frances; Tao, Xuguang; Bernacki, Edward

    2012-07-01

    To determine the price point at which an interferon-γ release assay (IGRA) is less costly than a tuberculin skin test (TST) for health care employee tuberculosis screening. A multidecision tree-based cost model incorporating inputs gathered from time-motion studies and parallel testing by IGRA and TST was conducted in a subset of our employees. Administering a TST testing program costs $73.20 per person screened, $90.80 per new hire, and $63.42 per annual screen. Use of an IGRA for employee health testing is cost saving at an IGRA test cost of $54.83 or less per test and resulted in higher completion rates because of the elimination of the need for a second visit to interpret the TST. Using an IGRA for employee health screening can be an institutional cost saving and results in higher compliance rates.

  13. Preseason Functional Movement Screen Component Tests Predict Severe Contact Injuries in Professional Rugby Union Players.

    Science.gov (United States)

    Tee, Jason C; Klingbiel, Jannie F G; Collins, Robert; Lambert, Mike I; Coopoo, Yoga

    2016-11-01

    Tee, JC, Klingbiel, JFG, Collins, R, Lambert, MI, and Coopoo, Y. Preseason Functional Movement Screen component tests predict severe contact injuries in professional rugby union players. J Strength Cond Res 30(11): 3194-3203, 2016-Rugby union is a collision sport with a relatively high risk of injury. The ability of the Functional Movement Screen (FMS) or its component tests to predict the occurrence of severe (≥28 days) injuries in professional players was assessed. Ninety FMS test observations from 62 players across 4 different time periods were compared with severe injuries sustained during 6 months after FMS testing. Mean composite FMS scores were significantly lower in players who sustained severe injury (injured 13.2 ± 1.5 vs. noninjured 14.5 ± 1.4, Effect Size = 0.83, large) because of differences in in-line lunge (ILL) and active straight leg raise scores (ASLR). Receiver-operated characteristic curves and 2 × 2 contingency tables were used to determine that ASLR (cut-off 2/3) was the injury predictor with the greatest sensitivity (0.96, 95% confidence interval [CI] = 0.79-1.0). Adding the ILL in combination with ASLR (ILL + ASLR) improved the specificity of the injury prediction model (ASLR specificity = 0.29, 95% CI = 0.18-0.43 vs. ASLR + ILL specificity = 0.53, 95% CI = 0.39-0.66, p ≤ 0.05). Further analysis was performed to determine whether FMS tests could predict contact and noncontact injuries. The FMS composite score and various combinations of component tests (deep squat [DS] + ILL, ILL + ASLR, and DS + ILL + ASLR) were all significant predictors of contact injury. The FMS composite score also predicted noncontact injury, but no component test or combination thereof produced a similar result. These findings indicate that low scores on various FMS component tests are risk factors for injury in professional rugby players.

  14. The usefulness of esophagography as a screening test for laryngopharyngeal reflux

    International Nuclear Information System (INIS)

    Kim, Tae Hoon; Chung, Phil Sang

    2006-01-01

    There are many articles about the role of barium esophagography for the diagnosis of gastroesophageal reflux disease. However, there are only rare articles reporting on laryngopharyngeal reflux disease. The purpose of this study is to evaluate the usefulness of performing esophagography with the water-siphon test as an initial screening test for patients with suspected laryngopharyngeal reflux. From October 2002 to December 2004, barium esophagography with the water-siphon test was performed for 707 patients who had the typical symptoms and telescopic findings of laryngopharyngeal reflux. The results of the 707 esophagograms (the group with laryngopharyngeal reflux) were compared with those of 122 patients who were confirmed as having gastroesophageal reflux upon performing pH-metry (the group with gastroesophageal reflux) and the 324 patients without laryngopharyngeal reflux symptoms (the control group). The results of the water-siphon test were classified into normal, mild, moderate and severe degrees of gastroesophageal reflux. On the water-siphon test for the laryngopharyneal reflux group patients, 71 patients had normal (10.0%), 207 had mild (29.2%), 201 had moderate (28.4%) and 228 had severe (32.2%) degrees of reflux. The positive rates of the water-siphon test were 90.0%, 89.3% and 54.6% for the groups with laryngopharyngeal reflux, gastroesophageal reflux and the control group, respectively. A statistically significant difference was observed between the group with laryngopharyngeal reflux and the control group, and between the group with gastroesophageal reflux and the control group, respectively (ρ < 0.05). Esophagography with the water-siphon test is useful as an initial screening test for laryngopharyngeal reflux disease

  15. Budget impact analysis of chronic kidney disease mass screening test in Japan.

    Science.gov (United States)

    Kondo, Masahide; Yamagata, Kunihiro; Hoshi, Shu-Ling; Saito, Chie; Asahi, Koichi; Moriyama, Toshiki; Tsuruya, Kazuhiko; Konta, Tsuneo; Fujimoto, Shouichi; Narita, Ichiei; Kimura, Kenjiro; Iseki, Kunitoshi; Watanabe, Tsuyoshi

    2014-12-01

    Our recently published cost-effectiveness study on chronic kidney disease mass screening test in Japan evaluated the use of dipstick test, serum creatinine (Cr) assay or both in specific health checkup (SHC). Mandating the use of serum Cr assay additionally, or the continuation of current policy mandating dipstick test only was found cost-effective. This study aims to examine the affordability of previously suggested reforms. Budget impact analysis was conducted assuming the economic model would be good for 15 years and applying a population projection. Costs expended by social insurers without discounting were counted as budgets. Annual budget impacts of mass screening compared with do-nothing scenario were calculated as ¥79-¥-1,067 million for dipstick test only, ¥2,505-¥9,235 million for serum Cr assay only and ¥2,517-¥9,251 million for the use of both during a 15-year period. Annual budget impacts associated with the reforms were calculated as ¥975-¥4,129 million for mandating serum Cr assay in addition to the currently used mandatory dipstick test, and ¥963-¥4,113 million for mandating serum Cr assay only and abandoning dipstick test. Estimated values associated with the reform from ¥963-¥4,129 million per year over 15 years are considerable amounts of money under limited resources. The most impressive finding of this study is the decreasing additional expenditures in dipstick test only scenario. This suggests that current policy which mandates dipstick test only would contain medical care expenditure.

  16. The usefulness of esophagography as a screening test for laryngopharyngeal reflux

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Tae Hoon; Chung, Phil Sang [Dankook University Hospital, Cheonan (Korea, Republic of)

    2006-04-15

    There are many articles about the role of barium esophagography for the diagnosis of gastroesophageal reflux disease. However, there are only rare articles reporting on laryngopharyngeal reflux disease. The purpose of this study is to evaluate the usefulness of performing esophagography with the water-siphon test as an initial screening test for patients with suspected laryngopharyngeal reflux. From October 2002 to December 2004, barium esophagography with the water-siphon test was performed for 707 patients who had the typical symptoms and telescopic findings of laryngopharyngeal reflux. The results of the 707 esophagograms (the group with laryngopharyngeal reflux) were compared with those of 122 patients who were confirmed as having gastroesophageal reflux upon performing pH-metry (the group with gastroesophageal reflux) and the 324 patients without laryngopharyngeal reflux symptoms (the control group). The results of the water-siphon test were classified into normal, mild, moderate and severe degrees of gastroesophageal reflux. On the water-siphon test for the laryngopharyneal reflux group patients, 71 patients had normal (10.0%), 207 had mild (29.2%), 201 had moderate (28.4%) and 228 had severe (32.2%) degrees of reflux. The positive rates of the water-siphon test were 90.0%, 89.3% and 54.6% for the groups with laryngopharyngeal reflux, gastroesophageal reflux and the control group, respectively. A statistically significant difference was observed between the group with laryngopharyngeal reflux and the control group, and between the group with gastroesophageal reflux and the control group, respectively ({rho} < 0.05). Esophagography with the water-siphon test is useful as an initial screening test for laryngopharyngeal reflux disease.

  17. Implementation of a Computerized Screening Inventory: Improved Usability Through Iterative Testing and Modification.

    Science.gov (United States)

    Boudreaux, Edwin D; Fischer, Andrew Christopher; Haskins, Brianna Lyn; Saeed Zafar, Zubair; Chen, Guanling; Chinai, Sneha A

    2016-03-09

    The administration of health screeners in a hospital setting has traditionally required (1) clinicians to ask questions and log answers, which can be time consuming and susceptible to error, or (2) patients to complete paper-and-pencil surveys, which require third-party entry of information into the electronic health record and can be vulnerable to error and misinterpretation. A highly promising method that avoids these limitations and bypasses third-party interpretation is direct entry via a computerized inventory. To (1) computerize medical and behavioral health screening for use in general medical settings, (2) optimize patient acceptability and feasibility through iterative usability testing and modification cycles, and (3) examine how age relates to usability. A computerized version of 15 screeners, including behavioral health screeners recommended by a National Institutes of Health Office of Behavioral and Social Sciences Research collaborative workgroup, was subjected to systematic usability testing and iterative modification. Consecutive adult, English-speaking patients seeking treatment in an urban emergency department were enrolled. Acceptability was defined as (1) the percentage of eligible patients who agreed to take the assessment (initiation rate) and (2) average satisfaction with the assessment (satisfaction rate). Feasibility was defined as the percentage of the screening items completed by those who initiated the assessment (completion rate). Chi-square tests, analyses of variance, and Pearson correlations were used to detect whether improvements in initiation, satisfaction, and completion rates were seen over time and to examine the relation between age and outcomes. Of 2157 eligible patients approached, 1280 agreed to complete the screening (initiation rate=59.34%). Statistically significant increases were observed over time in satisfaction (F3,1061=3.35, P=.019) and completion rates (F3,1276=25.44, PUsability testing revealed several critical

  18. Cost-effectiveness analysis of the optimal threshold of an automated immunochemical test for colorectal cancer screening: performances of immunochemical colorectal cancer screening.

    Science.gov (United States)

    Berchi, Célia; Guittet, Lydia; Bouvier, Véronique; Launoy, Guy

    2010-01-01

    Most industrialized countries, including France, have undertaken to generalize colorectal cancer screening using guaiac fecal occult blood tests (G-FOBT). However, recent researches demonstrate that immunochemical fecal occult blood tests (I-FOBT) are more effective than G-FOBT. Moreover, new generation I-FOBT benefits from a quantitative reading technique allowing the positivity threshold to be chosen, hence offering the best balance between effectiveness and cost. We aimed at comparing the cost and the clinical performance of one round of screening using I-FOBT at different positivity thresholds to those obtained with G-FOBT to determine the optimal cut-off for I-FOBT. Data were derived from an experiment conducted from June 2004 to December 2005 in Calvados (France) where 20,322 inhabitants aged 50-74 years performed both I-FOBT and G-FOBT. Clinical performance was assessed by the number of advanced tumors screened, including large adenomas and cancers. Costs were assessed by the French Social Security Board and included only direct costs. Screening using I-FOBT resulted in better health outcomes and lower costs than screening using G-FOBT for thresholds comprised between 75 and 93 ng/ml. I-FOBT at 55 ng/ml also offers a satisfactory alternative to G-FOBT, because it is 1.8-fold more effective than G-FOBT, without increasing the number of unnecessary colonoscopies, and at an extra cost of 2,519 euros per advanced tumor screened. The use of an automated I-FOBT at 75 ng/ml would guarantee more efficient screening than currently used G-FOBT. Health authorities in industrialized countries should consider the replacement of G-FOBT by an automated I-FOBT test in the near future.

  19. Active Parenting Now: Program Kit.

    Science.gov (United States)

    Popkin, Michael H.

    Based largely on the theories of Alfred Adler and Rudolf Dreikurs, this parent education curriculum is a video-based interactive learning experience that teaches a comprehensive model of parenting to parents of children ages 5 to 12 years. The kit provides parents with the skills needed to help their children develop courage, responsibility, and…

  20. Natural Gas Energy Educational Kit.

    Science.gov (United States)

    American Gas Association, Arlington, VA. Educational Services.

    Prepared by energy experts and educators to introduce middle school and high school students to natural gas and its role in our society, this kit is designed to be incorporated into existing science and social studies curricula. The materials and activities focus on the origin, discovery, production, delivery, and use of natural gas. The role of…

  1. Architectural Environment: A Resource Kit.

    Science.gov (United States)

    J.B. Speed Art Museum, Louisville, KY.

    There are many ways to approach the investigation of architecture. One can look at structural form, climate and topography, the aesthetics of style and decoration, building function, historical factors, cultural meanings, or technology and techniques associated with construction. This resource kit touches upon a few of these approaches, ranging…

  2. Work and Family Resource Kit.

    Science.gov (United States)

    Women's Bureau (DOL), Washington, DC.

    This kit is designed to help employers understand the range of family needs emerging in the workplace and the numerous options for a company response. An introduction discusses the need for child care services, dependent care problems, and how employers respond and benefit. Sections address the following: selecting the right option in relation to…

  3. Validity and Reliability of the Alcohol, Smoking, and Substance Involvement Screening Test (ASSIST) in University Students.

    Science.gov (United States)

    Tiburcio Sainz, Marcela; Rosete-Mohedano, Ma Guadalupe; Natera Rey, Guillermina; Martínez Vélez, Nora Angélica; Carreño García, Silvia; Pérez Cisneros, Daniel

    2016-03-02

    The Alcohol, Smoking and Substance Involvement Screening Test (ASSIST), developed by the World Health Organization (WHO), has been used successfully in many countries, but there are few studies of its validity and reliability for the Mexican population. The objective of this study was to determine the psychometric properties of the self-administered ASSIST test in university students in Mexico. This was an ex post facto non-experimental study with 1,176 undergraduate students, the majority women (70.1%) aged 18-23 years (89.5%) and single (87.5%). To estimate concurrent validity, factor analysis and tests of reliability and correlation were carried out between the subscale for alcohol and AUDIT, those for tobacco and the Fagerström Test, and those for marijuana and DAST-20. Adequate reliability coefficients were obtained for ASSIST subscales for tobacco (alpha = 0.83), alcohol (alpha = 0.76), and marijuana (alpha = 0.73). Significant correlations were found only with the AUDIT (r = 0.71) and the alcohol subscale. The best balance of sensitivity and specificity of the alcohol subscale (83.8% and 80%, respectively) and the largest area under the ROC curve (81.9%) was found with a cutoff score of 8. The self-administered version of ASSIST is a valid screening instrument to identify at-risk cases due to substance use in this population.

  4. Validation of the Danish Addenbrooke's Cognitive Examination as a screening test in a memory clinic.

    Science.gov (United States)

    Stokholm, Jette; Vogel, Asmus; Johannsen, Peter; Waldemar, Gunhild

    2009-01-01

    Addenbrooke's Cognitive Examination (ACE) is a cognitive screening test developed to detect dementia. It has been validated in several countries. Validation studies have predominantly included patients with various degrees of dementia and healthy controls. The aim of this study was to evaluate the Danish version of ACE as a screening test for early dementia in an outpatient memory clinic. Further, we wanted to investigate the ability of the ACE to discriminate patients with early Alzheimer's disease (AD) from patients with depression. 78 patients with mild AD (MMSE >or=20), 30 non-demented patients diagnosed with depression (originally referred for evaluation of cognitive symptoms), and 63 healthy volunteers, all between 60 and 85 years of age, were included. All patients were given the ACE as a supplement to the standard diagnostic work-up. The cut-off points for optimal trade-off between sensitivity and specificity for ACE were 85/86 (sensitivity 0.99, specificity 0.94). When these cut-off points were applied to the group of depressive patients, the specificity dropped to 0.64, indicating a great overlap in individual test scores for demented and depressed patients. The optimal cut-off points for ACE found in this Danish study were close to what is reported in most other European studies. The great overlap in ACE scores for demented and depressed patients emphasize that test scores must be interpreted with great caution when used in diagnostic work-up.

  5. Genetic screening and testing in an episode-based payment model: preserving patient autonomy.

    Science.gov (United States)

    Sutherland, Sharon; Farrell, Ruth M; Lockwood, Charles

    2014-11-01

    The State of Ohio is implementing an episode-based payment model for perinatal care. All costs of care will be tabulated for each live birth and assigned to the delivering provider, creating a three-tiered model for reimbursement for care. Providers will be reimbursed as usual for care that is average in cost and quality, while instituting rewards or penalties for those outside the expected range in either domain. There are few exclusions, and all methods of genetic screening and diagnostic testing are included in the episode cost calculation as proposed. Prenatal ultrasonography, genetic screening, and diagnostic testing are critical components of the delivery of high-quality, evidence-based prenatal care. These tests provide pregnant women with key information about the pregnancy, which, in turn, allows them to work closely with their health care provider to determine optimal prenatal care. The concepts of informed consent and decision-making, cornerstones of the ethical practice of medicine, are founded on the principles of autonomy and respect for persons. These principles recognize that patients' rights to make choices and take actions are based on their personal beliefs and values. Given the personal nature of such decisions, it is critical that patients have unbarred access to prenatal genetic tests if they elect to use them as part of their prenatal care. The proposed restructuring of reimbursement creates a clear conflict between patient autonomy and physician financial incentives.

  6. Performance of the Pentagon Drawing test for the screening of older adults with Alzheimer's dementia

    Directory of Open Access Journals (Sweden)

    José Eduardo Martinelli

    Full Text Available ABSTRACT The Pentagon Drawing Test (PDT is a common cognitive screening test. Objective: The aim of this study was to evaluate performance properties of a specific PDT scoring scale in older adults with Alzheimer's disease (AD and healthy controls. Methods: A cross-sectional study of 390 elderly patients, aged 60 years or older with at least two years of education was conducted. All participants completed clinical and neuropsychological evaluations, including the Cambridge Cognitive Examination, the Mini-Mental State Examination (MMSE, and the Clock Drawing Test. All PDT were blindly scored with the scale of Bourke et al. Results: PDT analyses of the binary score on the MMSE (0 or 1 point did not discriminate AD from controls (p = 0.839. However, when PDT was analyzed using the Bourke et al. scale, the two groups could be distinguished (p <0.001. PDT was not affected by education, showed sensitivity of 85.5% and specificity of 66.9%, discriminated different clinical stages of dementia, and correlated with the other cognitive tests (p <0.001. A 1-point difference on the Bourke et al. scale was associated with an odds ratio of 3.46 for AD. Conclusion: PDT can be used as a cognitive screen for suspected cases of dementia, especially AD, irrespective of educational level.

  7. [Faecal occult blood test for colorectal cancer screening: high quality for a good price].

    Science.gov (United States)

    van Veldhuizen, Harriët; Bonfrer, J M G Hans; Kuipers, Ernst J

    2013-01-01

    The Dutch National Institute for Public Health and the Environment (RIVM) awarded the immunochemical faecal occult blood test (IFOBT) to FOB Gold of Sentinel following a European call for tenders. The contract-awarding procedure included the application of quality knock-out criteria, which were met by two suppliers. The decisive factor was the best price/quality ratio. A recent review indicated that, at present, no single IFOBT is better than any other. The decision to opt for a test manufactured by a different supplier than was used in the previous screening pilots made it necessary to re-determine the cut-off value. This value has now been set (88 ng/ml) and is confirmed by a laboratory test. Colonoscopy-related capacity planning, as well as its diagnostic yield, depends on numerous factors; therefore, the RIVM is currently monitoring the referral percentage and number of adenomas detected and is collaborating on quality terms. Any necessary adjustments are to be made during the introduction of the screening test.

  8. In-bead screening

    DEFF Research Database (Denmark)

    2013-01-01

    The present invention relates to screening of one-bead-one-compound (OBOC) combinatorial libraries which is useful for the discovery of compounds displaying molecular interactions with a biological or a physicochemical system, such as substrates and inhibitors of enzymes and the like. The invention...... provides a method for screening a library of compounds for their interaction with a physico- chemical or biological system and a corresponding kit for performing the method of screening a one-bead-one-compound library of compounds....

  9. A Chinese version of the Language Screening Test (CLAST for early-stage stroke patients.

    Directory of Open Access Journals (Sweden)

    Hongyan Yang

    Full Text Available There is a severe lack of aphasia screening tools for bedside use in Chinese. A number of aphasia assessment tools have recently been developed abroad, but some of these scales were not suitable for patients with acute stroke. The Language Screening Test (which includes two parallel versions [a/b] in French has been proven to be an effective and time-saving aphasia screening scale for early-stage stroke patients. Therefore, we worked out a Chinese version of the LAST taking into consideration Chinese language and culture. Two preliminary parallel versions (a/b were tested on 154 patients with stroke at acute phase and 107 patients with stroke at non-acute phase, with the Western Aphasia Battery serving as a gold standard. The equivalence between the two parallel versions and the reliability/validity of each version were assessed. The median time to complete one preliminary Chinese version (each had some item redundancy was 98 seconds. Two final parallel versions were established after adjustment/elimination of the redundant items and were found to be equivalent (intra-class correlation coefficient: 0.991. Internal consistency is(Cronbach α for each version [a/b] was 0.956 and 0.965, respectively good. Internal validity was fine: (a no floor or ceiling effect/item redundancy; (b construct validity revealed a 1-dimension structure, just like the French version. The higher educated subjects scored higher than their lower educated counterparts (p<0.01. The external validity: at the optimum cut-off point where the score of version a/b <14 in higher educated group(<13 in lower: the specificity of each version was 0.878/0.902(1/1 in lower and sensitivity was 0.972/0.944(0.944/0.944 in lower. Inter-rater equivalence (intra-class correlation coefficient was 1. The Chinese version of the Language Screening Test was proved to be an efficient and time-saving bedside aphasia screening tool for stroke patients at acute phase and can be used by an average

  10. Opportunistic testing versus organized prostate-specific antigen screening: outcome after 18 years in the Göteborg randomized population-based prostate cancer screening trial.

    Science.gov (United States)

    Arnsrud Godtman, Rebecka; Holmberg, Erik; Lilja, Hans; Stranne, Johan; Hugosson, Jonas

    2015-09-01

    It has been shown that organized screening decreases prostate cancer (PC) mortality, but the effect of opportunistic screening is largely unknown. To compare the ability to reduce PC mortality and the risk of overdiagnosis between organized and opportunistic screening. The Göteborg screening study invited 10 000 randomly selected men for prostate-specific antigen (PSA) testing every 2 yr since 1995, with a prostate biopsy recommended for men with PSA ≥2.5 ng/ml. The control group of 10 000 men not invited has been exposed to a previously reported increased rate of opportunistic PSA testing. Both groups were followed until December 31, 2012. Observed cumulative PC incidence and mortality rates in both groups were calculated using the actuarial method. Using historical data from 1990-1994 (pre-PSA era), we calculated expected PC incidence and mortality rates in the absence of any PSA testing. The number needed to invite (NNI) and the number needed to diagnose (NND) were calculated by comparing the expected versus observed incidence and mortality rates. At 18 yr, 1396 men were diagnosed with PC and 79 men died of PC in the screening group, compared to 962 and 122, respectively, in the control group. In the screening group, the observed cumulative PC incidence/mortality was 16%/0.98% compared to expected values of 6.8%/1.7%. The corresponding values for the control group were 11%/1.5% and 6.9%/1.7%. Organized screening was associated with an absolute PC-specific mortality reduction of 0.72% (95% confidence interval [CI] 0.50-0.94%) and relative risk reduction of 42% (95% CI 28-54%). There was an absolute reduction in PC deaths of 0.20% (95% CI -0.06% to 0.47%) and a relative risk reduction of 12% (95% CI -5 to 26%) associated with opportunistic PSA testing. NNI and NND were 139 (95% CI 107-200) and 13 for organized biennial screening and 493 (95% CI 213- -1563) and 23 for opportunistic screening. The extent of opportunistic screening could not be measured

  11. Mammography and Pap test screening among low-income foreign-born Hispanic women in the USA

    Directory of Open Access Journals (Sweden)

    Fernandez Maria E.

    1998-01-01

    Full Text Available Little is known about the factors influencing screening among low-income Hispanic women particularly among recent immigrants. A sample of 148 low-income, low-literate, foreign-born Hispanic women residing in the Washington DC metropolitan area participated in the study. The mean age of the sample was 46.2 (SD = 11.5, 84% reported annual household incomes<=$15,000. All women were Spanish speakers and had low acculturation levels. Ninety six percent had reported having a Pap smear, but 24% were not in compliance with recommended screening (Pap test within the last 3 years. Among women 40 and older, 62% had received a mammogram, but only 33% were compliant with age appropriate recommended mammography screening guidelines. Women in this study had more misconceptions about cancer than Hispanics in other studies. Multivariate logistic models for correlates of Pap test and mammography screening behavior indicate that factors such as fear of the screening test, embarrassment, and lack of knowledge influenced screening behavior. In conclusion, women in this study had lower rates of mammography screening than non-Hispanic women and lower rates of compliance with recommended Mammography and Pap test screening guidelines.

  12. Impact of gender on decisions to participate in faecal immunochemical test-based colorectal cancer screening: a qualitative study.

    Science.gov (United States)

    Clarke, Nicholas; Gallagher, Pamela; Kearney, Patricia M; McNamara, Deirdre; Sharp, Linda

    2016-12-01

    Faecal immunochemical tests (FITs) are increasingly being used in population-based colorectal cancer-screening programmes. Uptake of FIT is lower in men than women; however, the reasons for this are not well understood. We aimed to explore gender differences in influences on decisions to participate in FIT screening. This is a qualitative study using in-depth face-to-face interviews of four groups of screening invitees (male and female screening users and male and female screening non-users), purposively sampled from the database of a population-based FIT screening programme. Recruitment continued until saturation was reached. Interviews were audio recorded and transcribed verbatim. Thematic analysis using the framework approach was employed with the theoretical domains framework guiding analysis. Forty-seven screening invitees were interviewed. Six theoretical domains influenced screening uptake: 'environmental context and resources', 'beliefs about capabilities', 'beliefs about consequences', 'emotions', 'social influences' and 'knowledge'. Male non-users were often fatalistic, less knowledgeable and misinformed about cancer and FIT screening compared with other groups. Female non-users expressed negative attitudes, beliefs and emotions towards FIT screening, cancer, social influences and the medical profession and were over-confident about their health. Negative attitudes and emotions to screening dominated non-user decision-making but differed by gender. Opportunities to improve uptake in men and women exist. Greater national discussions on the benefits of FIT screening, and development of screening materials tackling negative attitudes and beliefs while recognising male/female differences, may improve screening uptake. Copyright © 2016 John Wiley & Sons, Ltd. Copyright © 2016 John Wiley & Sons, Ltd.

  13. Red Blood Cell Antibody Screen: MedlinePlus Lab Test Information

    Science.gov (United States)

    ... medlineplus.gov/labtests/redbloodcellantibodyscreen.html Red Blood Cell Antibody Screen To use the sharing features on this page, please enable JavaScript. What is an RBC Antibody Screen? An RBC (red blood cell) antibody screen ...

  14. Verification testing of the compression performance of the HEVC screen content coding extensions

    Science.gov (United States)

    Sullivan, Gary J.; Baroncini, Vittorio A.; Yu, Haoping; Joshi, Rajan L.; Liu, Shan; Xiu, Xiaoyu; Xu, Jizheng

    2017-09-01

    This paper reports on verification testing of the coding performance of the screen content coding (SCC) extensions of the High Efficiency Video Coding (HEVC) standard (Rec. ITU-T H.265 | ISO/IEC 23008-2 MPEG-H Part 2). The coding performance of HEVC screen content model (SCM) reference software is compared with that of the HEVC test model (HM) without the SCC extensions, as well as with the Advanced Video Coding (AVC) joint model (JM) reference software, for both lossy and mathematically lossless compression using All-Intra (AI), Random Access (RA), and Lowdelay B (LB) encoding structures and using similar encoding techniques. Video test sequences in 1920×1080 RGB 4:4:4, YCbCr 4:4:4, and YCbCr 4:2:0 colour sampling formats with 8 bits per sample are tested in two categories: "text and graphics with motion" (TGM) and "mixed" content. For lossless coding, the encodings are evaluated in terms of relative bit-rate savings. For lossy compression, subjective testing was conducted at 4 quality levels for each coding case, and the test results are presented through mean opinion score (MOS) curves. The relative coding performance is also evaluated in terms of Bjøntegaard-delta (BD) bit-rate savings for equal PSNR quality. The perceptual tests and objective metric measurements show a very substantial benefit in coding efficiency for the SCC extensions, and provided consistent results with a high degree of confidence. For TGM video, the estimated bit-rate savings ranged from 60-90% relative to the JM and 40-80% relative to the HM, depending on the AI/RA/LB configuration category and colour sampling format.

  15. Biological screening of chitosan derivatives using Artemia spp. (brine shrimp test)

    International Nuclear Information System (INIS)

    Rozaini Mohd Zohdi; Norimah Yusof; Asnah Hassan

    2006-01-01

    The present study reported on the screening of six selected chitosan derivatives using the brine shrimp lethality bioassay. In addition, the irradiation effects towards the compounds at 25 kGy were also studied. Chitosan is a natural polysaccharide derived from chitin, extracted from the exoskeletons of crustaceans and insects as well as walls of some bacteria and fungi. Brine shrimp test is employed for the screening of toxicity of chitosan derivatives. Toxicity test was carried out by adding different concentrations of tested samples to approximately 5 to 15 Artemia salina larvae. Biological activity using the brine shrimp bioassay was recorded as LC 50 i.e. lethal concentration that kills 50% of the larvae within 24 hours of contact with the samples. Compounds are considered toxic when the LC 50 value is lower than 1 mg/ml by brine shrimp bioassay and practically non-toxic when the value is larger. Of the samples tested, none were toxic to the brine shrimp (LC 50 > 1 mg/ml). The LC 50 values of all chitosan derivatives tested, control and irradiated at 25 kGy were above 1 mg/ml thus all tested samples are considered non-toxic. This study demonstrated that irradiation at 25 kGy showed no significant effects towards the toxicity of the chitosan derivatives. After irradiation, only NO-CMC exhibited marked decrease in LC 50 value, reduced by 3-fold from 34.96 mg/ml to 11.07 mg/ml while O-CMC (5.45 mg/ml to 5 mg/ml) showed no clear differences based on rough estimation. This study suggested that brine shrimp bioassay is a simple, reliable and convenient method that could provide useful clues of the relative toxic potential of the sample tested. (Author)

  16. Suitability Screening Test for Marine Corps Air Traffic Controllers Phase 3: Non-cognitive Test Validation and Cognitive Test Prototype

    Science.gov (United States)

    2014-06-01

    developed, pilot tested, and in its Beta form. Findings or Results The subset of NCAPS traits that demonstrated statistically significant prediction for...development and initial pilot testing of the Prototype Marine ATC Cognitive Test. Method The validation approach chosen for this project was a criterion... multitasking ability, and 5) inductive reasoning ability. A working memory capacity test was developed because working memory has been linked to

  17. Development of a fast agglutination screening test (FAST) for the detection of anti-Leishmania antibodies in dogs

    NARCIS (Netherlands)

    Schallig, H. D. F. H.; Schoone, G. J.; Beijer, E. G. M.; Kroon, C. C. M.; Hommers, M.; Ozbel, Y.; Ozensoy, S.; da Silva, E. S.; Cardoso, L. M.; da Silva, E. D.

    2002-01-01

    A fast agglutination screening test (FAST) for the detection of anti-Leishinania antibodies in serum samples from dogs with visceral leishmamosis was developed. The test is based on the direct agglutination test (DAT), but combines a higher parasite concentration with a smaller test volume. In

  18. Development of a simple screening test to detect and determine the microbiological quality of irradiated foods

    International Nuclear Information System (INIS)

    Jones, K.L.; MacPhee, S.M.; Turner, A.J.; Stuckey, T.; Betts, R.P.

    1995-07-01

    The direct epifluorescent filter technique/aerobic plate count (DEFT/APC) method is a recognised technique for the screening of irradiated foods. When the APC of an irradiated sample is compared with the DEFT count on the same sample, the APC is found to be considerably lower than that obtained by the DEFT, thus indicating that the sample could have been irradiated. Since the development of the DEFT/APC screening method, the technique has been tested with a limited range of food products. Previous work has indicated that the storage of irradiated foods can, in certain circumstances, allow microorganisms to grow, and thus compromise the ability of the DEFT/APC method to discriminate between irradiated and unirradiated samples. In some cases the method has been shown to give high DEFT count and low APC with food samples that have not been irradiated. Potentially, foods which have undergone a food processing treatment could give a high DEFT count compared to an APC and be erroneously identified as having been irradiated. The work reported here is aimed at analysing a range of irradiated samples (meat, poultry, fish, seafood, herbs and spices), stored under different conditions, to evaluate the applicability of the screening method for use with such products. The effects of other food processes on the DEFT/APC results were also investigated. (UK)

  19. Personal values that support and counteract utilization of a screening test for prostate cancer.

    Science.gov (United States)

    Aavik, Toivo; Aavik, Anu; Punab, Margus

    2014-01-01

    The main aim of the current research was to discover the personal values that may support men's prostate cancer screening decisions in the future. We asked for participants' past behavior and future behavioral intentions, and also considered their real-life behavior. The sample consisted of 371 men, of which 93 were first-time patients at the Andrology Unit. The results show that Security value was related to past participation, while Achievement, Stimulation, and Traditions counteracted this. Present prostate-testing behavior was related only to higher Security values. Predictors of future behavioral intentions were Security, Self-direction, and Benevolence, which described 21% of the total variability. Considering informed decision-making processes, our results suggest that men who hold Security, Self-direction, and Benevolence values are more likely to participate in office-based initial screening. The study indicates the need to offer office-based initial screening to those age-eligible men whose values do not support participation.

  20. Screening for prostate cancer with the prostate-specific antigen test: are patients making informed decisions?

    Science.gov (United States)

    O'Dell, K J; Volk, R J; Cass, A R; Spann, S J

    1999-09-01

    The benefits of early detection of prostate cancer are uncertain, and the American College of Physicians and the American Academy of Family Physicians recommend individual decision making in prostate cancer screening. This study reports the knowledge of male primary care patients about prostate cancer and prostate-specific antigen (PSA) testing and examines how that knowledge is related to PSA testing, preferences for testing in the future, and desire for involvement in physician-patient decision making. The sample included 160 men aged 45 to 70 years with no history of prostate cancer who presented for care at a university-based family medicine clinic. Before scheduled office visits, patients completed a questionnaire developed for this study that included a 10-question measure of prostate cancer knowledge, the Deber-Kraestchmer Problem-Solving Decision-Making Scale, sociodemographic indicators, and questions on PSA testing. In general, patients who were college graduates were more knowledgeable about prostate cancer and early detection than those with a high school education or less. Aside from college graduates, most patients could not identify the principle advantages and disadvantages of PSA testing. Patients indicating previous or future plans for PSA testing demonstrated greater knowledge than other patients. Desire for involvement in decision making varied by patient education but was not related to past PSA testing. Patients lack knowledge about prostate cancer and early detection. This knowledge deficit may impede the early detection of prostate cancer and is a barrier to making an informed decision about undergoing PSA testing.

  1. The Q* Index: A Useful Global Measure of Dementia Screening Test Accuracy

    Directory of Open Access Journals (Sweden)

    A.J. Larner

    2015-06-01

    Full Text Available Background/Aims: Single, global or unitary, indicators of test diagnostic performance have intuitive appeal for clinicians. The Q* index, the point in receiver operating characteristic (ROC curve space closest to the ideal top left-hand corner and where test sensitivity and specificity are equal, is one such measure. Methods: Datasets from four pragmatic accuracy studies which examined the Mini-Mental State Examination, Addenbrooke's Cognitive Examination-Revised, Montreal Cognitive Assessment, Test Your Memory test, and Mini-Addenbrooke's Cognitive Examination were examined to calculate and compare the Q* index, the maximal correct classification accuracy, and the maximal Youden index, as well as the sensitivity and specificity at these cutoffs. Results: Tests ranked similarly for the Q* index and the area under the ROC curve (AUC ROC. The Q* index cutoff was more sensitive (and less specific than the maximal correct classification accuracy cutoff, and less sensitive (and more specific than the maximal Youden index cutoff. Conclusion: The Q* index may be a useful global parameter summarising the test accuracy of cognitive screening instruments, facilitating comparison between tests, and defining a possible test cutoff value. As the point of equal sensitivity and specificity, its use may be more intuitive and appealing for clinicians than AUC ROC.

  2. Significance of Intratracheal Instillation Tests for the Screening of Pulmonary Toxicity of Nanomaterials.

    Science.gov (United States)

    Morimoto, Yasuo; Izumi, Hiroto; Yoshiura, Yukiko; Fujisawa, Yuri; Fujita, Katsuhide

    Inhalation tests are the gold standard test for the estimation of the pulmonary toxicity of respirable materials. Intratracheal instillation tests have been used widely, but they yield limited evidence of the harmful effects of respirable materials. We reviewed the effectiveness of intratracheal instillation tests for estimating the hazards of nanomaterials, mainly using research papers featuring intratracheal instillation and inhalation tests centered on a Japanese national project. Compared to inhalation tests, intratracheal instillation tests induced more acute inflammatory responses in the animal lung due to a bolus effect regardless of the toxicity of the nanomaterials. However, nanomaterials with high toxicity induced persistent inflammation in the chronic phase, and nanomaterials with low toxicity induced only transient inflammation. Therefore, in order to estimate the harmful effects of a nanomaterial, an observation period of 3 months or 6 months following intratracheal instillation is necessary. Among the endpoints of pulmonary toxicity, cell count and percentage of neutrophil, chemokines for neutrophils and macrophages, and oxidative stress markers are considered most important. These markers show persistent and transient responses in the lung from nanomaterials with high and low toxicity, respectively. If the evaluation of the pulmonary toxicity of nanomaterials is performed in not only the acute but also the chronic phase in order to avoid the bolus effect of intratracheal instillation and inflammatory-related factors that are used as endpoints of pulmonary toxicity, we speculate that intratracheal instillation tests can be useful for screening for the identification of the hazard of nanomaterials through pulmonary inflammation.

  3. Jaw-opening force test to screen for Dysphagia: preliminary results.

    Science.gov (United States)

    Hara, Koji; Tohara, Haruka; Wada, Satoko; Iida, Takatoshi; Ueda, Koichiro; Ansai, Toshihiro

    2014-05-01

    To assess the jaw-opening force test (JOFT) for dysphagia screening. Criterion standard. University dental hospital. Patients complaining of dysphagia (N=95) and with symptoms of dysphagia with chronic underlying causes (mean age ± SD, 79.3±9.61y; range, 50-94y; men: n=49; mean age ± SD, 77.03±9.81y; range, 50-94y; women: n=46; mean age ± SD, 75.42±9.73y; range, 51-93y) admitted for treatment between May 2011 and December 2012 were included. None. All patients were administered the JOFT and underwent fiberoptic endoscopic evaluation of swallowing (FEES). The mean jaw-opening strength was compared with aspiration (ASP) and pharyngeal residue observations of the FEES, which was used as the criterion standard. A receiver operating characteristic (ROC) curve analysis was performed. Forces of ≤3.2kg for men and ≤4kg for women were appropriate cutoff values for predicting ASP with a sensitivity and specificity of .57 and .79 for men and .93 and .52 for women, respectively. Based on the ROC analyses for predicting pharyngeal residue, forces of ≤5.3kg in men and ≤3.9kg in women were appropriate cutoff values, with a sensitivity and specificity of .80 and .88 for men and .83 and .81 for women, respectively. The JOFT could be a useful screening tool for predicting pharyngeal residue and could provide useful information to aid in the referral of patients for further diagnostic imaging testing. However, given its low sensitivity to ASP the JOFT should be paired with other screening tests that predict ASP. Copyright © 2014 American Congress of Rehabilitation Medicine. Published by Elsevier Inc. All rights reserved.

  4. Hematuria screening test for urinary bladder mucosal infiltration in cervical cancer.

    Science.gov (United States)

    Chuttiangtum, Ayuth; Udomthavornsuk, Banchong; Chumworathayi, Bandit

    2012-01-01

    To determine the diagnostic performance of hematuria as a screening test for urinary bladder infiltration in cervical cancer patients with a prospective study design. Newly diagnosed cervical cancer patients at Srinagarind hospital from 14 June 2011 to 30 April 2012 were enrolled in this study. We collected midstream urine samples for urinalysis from every patient before routine cystoscopic exam for clinical staging. The presence of 3 or more red blood cells (RBCs) per high power field was defined as positive for hematuria. A two-by-two table was used to determine the diagnostic performance of hematuria to detect urinary bladder mucosal infiltration using cystoscopy and biopsy as the gold standard. A total of 130 were patients included, 54 of which (41.5%) had hematuria. Of these, four patients (3.08%) had pathological report from cystoscopic biopsy confirmed metastatic squamous cell carcinoma. The sensitivity, specificity, PPV, NPV, and accuracy of hematuria as a screening test to detect urinary bladder mucosal infiltration of cervical cancer were 100%, 60.3%, 7.4%, 100%, and 61.5%, respectively. There was no single case of urinary bladder mucosal infiltration in patients initially staged less than stage III. Hematuria can be used as a screening test to detect urinary bladder mucosal infiltration of cervical cancer. This can reduce the number of cervical cancer patients who really need to undergo cystoscopy as a staging procedure to less than half and to less than 20% if stage III or more were included without missing a single case of urinary bladder mucosal infiltration.

  5. Six years of vision screening tests in pre-school children in kindergartens of Wroclaw

    Science.gov (United States)

    Szmigiel, Marta; Geniusz, Malwina; Szmigiel, Ireneusz

    2017-09-01

    Detection of vision defects of a child without professional knowledge is not easy. Very often, the parents of a small child does not know that their child sees incorrect. Also the youngster, not knowing any other way of seeing, does not know that it is not the best. While the vision of a small child is not yet fully formed, it is worth checking them very early. Defects detected early gives opportunity for the correction of anomalies, which might give the effect of the normal development of vision. According to the indications, the American Optometric Association (AOA) control eye examination should be performed between the ages of 6 months to 3 years, before going to school and then every two years. Members of SPIE Student Chapter, in cooperation with the Visual Optics Group working on the Department of Optics and Photonics (Faculty of Fundamental Problems, Wroclaw University of Science and Technology) for 6 years offer selected kindergartens of Wroclaw participation in project "Screening vision tests in pre-school children". Depending on the number of involved members of the student chapter and willing to cooperate students of Ophthalmology and Optometry, vision screening test was carried out in up to eight kindergartens every year. The basic purpose of screening vision test is to detect visual defects to start the correction so early in life as possible, while increasing the efficiency of the child's visual potential. The surrounding community is in fact more than enough examples of late diagnose vision problems, which resulted in lack of opportunity or treatment failure

  6. Results of screening NCI/NTP nongenotoxic carcinogens and genotoxic noncarcinogens with the ke test

    International Nuclear Information System (INIS)

    Mendelsohn, M.L.; Bakale, G.; McCreary, R.D.

    1989-01-01

    The interdependence of the electrophilic and carcinogenic properties of chemicals that was demonstrated two decades ago rekindled interest in the somatic mutation theory of carcinogenesis. Interest in this theory grew with the development of a reverse-mutation bacterial assay in the laboratory of B.N. Ames that permitted the mutagenic properties of the chemicals to be determined quickly and yielded results which indicated that ''carcinogens are mutagens.'' Subsequent validation studies of this bioassay, the Salmonella typhimurium/microsome or ''Ames test,'' by Ames' group and others provided additional support for the correlation between mutagenicity and carcinogenicity which led to the worldwide deployment of the Ames test in thousands of laboratories and to the development of more than 100 other short-term tests that continue to be used to identify potential carcinogens via various end-points of genotoxicity. This document discusses electrophilicity, mutagenicity, and carcinogenicity relationships as well as carcinogen-screening of chemicals. 28 refs., 4 tabs