  1. Screen-film mammography

    International Nuclear Information System (INIS)

    Logan, W.W.; Janus, J.A.

    1987-01-01

    The development of screen-film mammography has resulted in the re-emergence of confidence, rather than fear, in mammography. When screen-film mammography is performed with state-of-the-art dedicated equipment utilizing vigorous breast compression and a ''soft'' x-ray beam for improved contrast, screen-film images are equivalent or superior to those of reduced-dose xeromammography and superior to those of nonscreen film mammography. Technological aids for conversion from xeromammographic or nonscreen film mammographic techniques to screen-film techniques have been described. Screen-film mammography should not be attempted until dedicated equipment has been obtained and the importance of vigorous compression has been understood

  2. Quality Imaging - Comparison of CR Mammography with Screen-Film Mammography

    International Nuclear Information System (INIS)

    Gaona, E.; Azorin Nieto, J.; Iran Diaz Gongora, J. A.; Arreola, M.; Casian Castellanos, G.; Perdigon Castaneda, G. M.; Franco Enriquez, J. G.

    2006-01-01

    The aim of this work is a quality imaging comparison of CR mammography images printed to film by a laser printer with screen-film mammography. A Giotto and Elscintec dedicated mammography units with fully automatic exposure and a nominal large focal spot size of 0.3 mm were used for the image acquisition of phantoms in screen-film mammography. Four CR mammography units from two different manufacturers and three dedicated x-ray mammography units with fully automatic exposure and a nominal large focal spot size of 0.3 mm were used for the image acquisition of phantoms in CR mammography. The tests quality image included an assessment of system resolution, scoring phantom images, Artifacts, mean optical density and density difference (contrast). In this study, screen-film mammography with a quality control program offers a significantly greater level of quality image relative to CR mammography images printed on film

  3. Tests with films and film-screens using grid-mammography

    International Nuclear Information System (INIS)

    Wolf, G.; Kallinger, G.

    1982-01-01

    A comparison was made between mammography using grid-technique with a film-screen-system and mammography without grid, and with film-screens and also using industrial films. The image-quality of grid mammography looks like the same than using conventional techniques and industrial films. The problem of soft tissue grid techniques lies in the dose requirements, which was more than using film-screen-techniques without grid. New and improved recording systems, which reduce radiation dose when using the grid technique were analyzed. (orig.) [de

  4. Population-based mammography screening: comparison of screen-film and full-field digital mammography with soft-copy reading--Oslo I study.

    Science.gov (United States)

    Skaane, Per; Young, Kari; Skjennald, Arnulf

    2003-12-01

    To compare screen-film and full-field digital mammography with soft-copy reading in a population-based screening program. Full-field digital and screen-film mammography were performed in 3,683 women aged 50-69 years. Two standard views of each breast were acquired with each modality. Images underwent independent double reading with use of a five-point rating scale for probability of cancer. Recall rates and positive predictive values were calculated. Cancer detection rates determined with both modalities were compared by using the McNemar test for paired proportions. Retrospective side-by-side analysis for conspicuity of cancers was performed by an external independent radiologist group with experience in both modalities. In 3,683 cases, 31 cancers were detected. Screen-film mammography depicted 28 (0.76%) malignancies, and full-field digital mammography depicted 23 (0.62%) malignancies. The difference between cancer detection rates was not significant (P =.23). The recall rate for full-field digital mammography (4.6%; 168 of 3,683 cases) was slightly higher than that for screen-film mammography (3.5%; 128 of 3,683 cases). The positive predictive value based on needle biopsy results was 46% for screen-film mammography and 39% for full-field digital mammography. Side-by-side image comparison for cancer conspicuity led to classification of 19 cancers as equal for probability of malignancy, six cancers as slightly better demonstrated at screen-film mammography, and six cancers as slightly better demonstrated at full-field digital mammography. There was no statistically significant difference in cancer detection rate between screen-film and full-field digital mammography. Cancer conspicuity was equal with both modalities. Full-field digital mammography with soft-copy reading is comparable to screen-film mammography in population-based screening.

  5. A comparison of the accuracy of film-screen mammography, full-field digital mammography, and digital breast tomosynthesis

    International Nuclear Information System (INIS)

    Michell, M.J.; Iqbal, A.; Wasan, R.K.; Evans, D.R.; Peacock, C.; Lawinski, C.P.; Douiri, A.; Wilson, R.; Whelehan, P.

    2012-01-01

    Aim: To measure the change in diagnostic accuracy of conventional film-screen mammography and full-field digital mammography (FFDM) with the addition of digital breast tomosynthesis (DBT) in women recalled for assessment following routine screening. Materials and methods: Ethics approval for the study was granted. Women recalled for assessment following routine screening with screen-film mammography were invited to participate. Participants underwent bilateral, two-view FFDM and two-view DBT. Readers scored each lesion separately for probability of malignancy on screen-film mammography, FFDM, and then DBT. The scores were compared with the presence or absence of malignancy based on the final histopathology outcome. Results: Seven hundred and thirty-eight women participated (93.2% recruitment rate). Following assessment 204 (26.8%) were diagnosed as malignant (147 invasive and 57 in-situ tumours), 286 (37.68%) as benign, and 269 (35.4%) as normal. The diagnostic accuracy was evaluated by using receiving operating characteristic (ROC) and measurement of area under the curve (AUC). The AUC values demonstrated a significant (p = 0.0001) improvement in the diagnostic accuracy with the addition of DBT combined with FFDM and film-screen mammography (AUC = 0.9671) when compared to FFDM plus film-screen mammography (AUC = 0.8949) and film-screen mammography alone (AUC = 0.7882). The effect was significantly greater for soft-tissue lesions [AUC was 0.9905 with the addition of DBT and AUC was 0.9201 for FFDM with film-screen mammography combined (p = 0.0001)] compared to microcalcification [with the addition of DBT (AUC = 0.7920) and for FFDM with film-screen mammography combined (AUC = 0.7843; p = 0.3182)]. Conclusion: The addition of DBT increases the accuracy of mammography compared to FFDM and film-screen mammography combined and film-screen mammography alone in the assessment of screen-detected soft-tissue mammographic abnormalities.

  6. Studies Comparing Screen-Film Mammography and Full-Field Digital Mammography in Breast Cancer Screening: Updated Review

    International Nuclear Information System (INIS)

    Skaane, P.

    2009-01-01

    Full-field digital mammography (FFDM) has several potential benefits as compared with screen-film mammography (SFM) in mammography screening. Digital technology also opens for implementation of advanced applications, including computer-aided detection (CAD) and tomosynthesis. Phantom studies and experimental clinical studies have shown that FFDM is equal or slightly superior to SFM for detection and characterization of mammographic abnormalities. Despite obvious advantages, the conversion to digital mammography has been slower than anticipated, and not only due to higher costs. Until very recently, some countries did not even permit the use of digital mammography in breast cancer screening. The reason for this reluctant attitude was concern about lower spatial resolution and about using soft-copy reading. Furthermore, there was a lack of data supporting improved diagnostic accuracy using FFDM in a screening setting, since two pioneer trials both showed nonsignificantly lower cancer detection rate at FFDM. The 10 studies comparing FFDM and SFM in mammography screening published so far have shown divergent and rather conflicting results. Nevertheless, there is a rapid conversion to digital mammography in breast cancer screening in many western countries. The aim of this article is to give an updated review of these studies, discuss the conflicting findings, and draw some conclusions from the results

  7. A comparison of the performance of modern screen-film and digital mammography systems

    Energy Technology Data Exchange (ETDEWEB)

    Monnin, P [Institut Universitaire de Radiophysique Appliquee (IRA), CH-1007 Lausanne (Switzerland); Gutierrez, D [Institut Universitaire de Radiophysique Appliquee (IRA), CH-1007 Lausanne (Switzerland); Bulling, S [Institut Universitaire de Radiophysique Appliquee (IRA), CH-1007 Lausanne (Switzerland); Lepori, D [Department of Radiology, University Hospital Center (CHUV), CH-1011 Lausanne (Switzerland); Valley, J-F [Institut Universitaire de Radiophysique Appliquee (IRA), CH-1007 Lausanne (Switzerland); Verdun, F R [Institut Universitaire de Radiophysique Appliquee (IRA), CH-1007 Lausanne (Switzerland)

    2005-06-07

    This work compares the detector performance and image quality of the new Kodak Min-R EV mammography screen-film system with the Fuji CR Profect detector and with other current mammography screen-film systems from Agfa, Fuji and Kodak. Basic image quality parameters (MTF, NPS, NEQ and DQE) were evaluated for a 28 kV Mo/Mo (HVL = 0.646 mm Al) beam using different mAs exposure settings. Compared with other screen-film systems, the new Kodak Min-R EV detector has the highest contrast and a low intrinsic noise level, giving better NEQ and DQE results, especially at high optical density. Thus, the properties of the new mammography film approach those of a fine mammography detector, especially at low frequency range. Screen-film systems provide the best resolution. The presampling MTF of the digital detector has a value of 15% at the Nyquist frequency and, due to the spread size of the laser beam, the use of a smaller pixel size would not permit a significant improvement of the detector resolution. The dual collection reading technology increases significantly the low frequency DQE of the Fuji CR system that can at present compete with the most efficient mammography screen-film systems.

  8. Image quality in conventional film screen system, digital phosphor storage plate mammography in magnification technique and digital mammography in CCD-technique

    International Nuclear Information System (INIS)

    Schulz-Wendtland, R.; Aichinger, U.; Boehner, C.; Dobritz, M.; Bautz, W.; Saebel, M.

    2000-01-01

    Purpose: Comparison of image quality between conventional film screen system, digital phosphor storage plate mammography in magnification technique and digital mammography in CCD-technique. Materials and Methods: Radiograms of a RMI-mammography phantom were acquired using a conventional film screen system, two digital storage plate systems and two digital systems in CCD-technique. Additionally, the radiograms of one digital phosphor storage plate system were post-processed emphasizing contrast and included in the comparison. Results: The detectability of details was the best with the digital mammography in CCD-technique in comparison with the conventional film screen technique resp. digital phosphor storage plate in magnification technique. Conclusions: Based on these results there is the possibility to replace the conventional film screen system by further studies - this has to be confirmed. (orig.) [de

  9. Comparison of average glandular dose in screen-film and digital mammography using breast tissue-equivalent phantom

    International Nuclear Information System (INIS)

    Shin, Gwi Soon; Kim, Jung Min; Kim, You Hyun; Choi, Jong Hak; Kim, Chang Kyun

    2007-01-01

    In recent years, mammography system is changed rapidly from conventional screen-film system to digital system for application to screening and diagnosis. Digital mammography system provides several advantages over screen-film mammography system. According to the information provided by the manufacturer, digital mammography system offers radiation dose reduction in comparison with screen-film mammography system, because of digital detector, particularly direct digital detector has higher x-ray absorption efficiency than screen-film combination or imaging plate (IP). We measured average glandular doses (ADG) in screen-film mammography (SFM) system with slow screen-film combination, computed mammography (CM) system, indirect digital mammography (IDM) system and direct digital mammography (DDM) system using breast tissue-equivalent phantom (glandularity 30%, 50% and 70%). The results were shown as follows: AGD values for DDM system were highest than those for other systems. Although automatic exposure control (AEC) mode was selected, the curve of the AGD values against thickness or glandularity increased significantly for the SFM system with the uniform target/filter (Mo/Mo) combination. Therefore, the AGD values for the high energy examinations were highest in the SFM system, and those for the low energy examinations were highest in the DDM system. But the curve of the AGD values against thickness and glandularity increased gently for CM system with the automatic selection of the target/filter combination (from Mo/Mo to Mo/Rh or from Mo/Rh to Rh/Rh), and the AGD values were lowest. Consequently, the parameters in mammography for each exposure besides detection efficiency play an important role in order to estimate a patient radiation dose

  10. Digital versus screen-film mammography: impact of mammographic density and hormone therapy on breast cancer detection.

    Science.gov (United States)

    Chiarelli, Anna M; Prummel, Maegan V; Muradali, Derek; Shumak, Rene S; Majpruz, Vicky; Brown, Patrick; Jiang, Hedy; Done, Susan J; Yaffe, Martin J

    2015-11-01

    Most studies that have examined the effects of mammographic density and hormone therapy use on breast cancer detection have included screen-film mammography. This study further examines this association in post-menopausal women screened by digital mammography. Approved by the University of Toronto Research Ethics Board, this study identified 688,418 women of age 50-74 years screened with digital or screen-film mammography from 2008 to 2009 within the Ontario Breast Screening Program. Of 2993 eligible women with invasive breast cancer, 2450 were contacted and 1421 participated (847 screen-film mammography, 574 digital direct radiography). Mammographic density was measured by study radiologists using the standard BI-RADS classification system and by a computer-assisted method. Information on hormone therapy use was collected by a telephone-administered questionnaire. Logistic regression and two-tailed tests for significance evaluated associations between factors and detection method by mammography type. Women with >75 % radiologist-measured mammographic density compared to those with diagnosed with an interval than screen-detected cancer, with the difference being greater for those screened with screen-film (OR = 6.40, 95 % CI 2.30-17.85) than digital mammography (OR = 2.41, 95 % CI 0.67-8.58) and aged 50-64 years screened with screen-film mammography (OR = 10.86, 95 % CI 2.96-39.57). Recent former hormone therapy users were also at an increased risk of having an interval cancer with the association being significant for women screened with digital mammography (OR = 2.08, 95 % CI 1.17-3.71). Breast screening using digital mammography lowers the risk of having an interval cancer for post-menopausal women aged 50-64 with greater mammographic density.

  11. Film-Screen Mammography versus digital storage plate mammography: Hard copy and monitor display of microcalcifications and focal findings - A retrospective clinical and histologic analysis

    International Nuclear Information System (INIS)

    Schulz-Wendtland, R.; Wenkel, E.; Aichinger, U.; Tartsch, M.; Kuchar, I.; Bautz, W.

    2003-01-01

    Purpose: A retrospective clinical-histological study to determine the diagnostic accuracy of mammography using conventional screen-film cassettes (hard copy), high-resolution digital phosphor storage plates (hard copy) and monitor display (soft copy) for microcalcifications and focal lesions (BI-RADS TM category 4 or 5). Materials and methods: From April to November 2001, 76 patients underwent conventional film-screen mammography and, after diagnosis and preoperative wire localization, digital mammography with the same exposure parameters. Five investigators retrospectively determined the diagnosis after the operation from randomly distributed mediolateral views (hard-copy reading) and from the monitor display (soft-copy reading). These results were correlated with the final histology. Results: The accuracy of conventional screen-film mammography, digital mammography and monitor-displayed mammography was 67%, 65% and 68% for all findings, (n = 76), 59%, 59% and 68% for microcalcifications (n = 44) and 75%, 72% and 63% for focal lesions (n = 32). The overall results showed no difference. Conclusions: Our findings indicate equivalence of conventional screen-film mammography, high-resolution digital phosphor storage plate mammography and monitor-displayed mammography. (orig.) [de

  12. Screen film vs full-field digital mammography: image quality, detectability and characterization of lesions

    International Nuclear Information System (INIS)

    Obenauer, S.; Luftner-Nagel, S.; Heyden, D. von; Baum, F.; Grabbe, E.; Munzel, U.

    2002-01-01

    The objective of this study was to compare screen-film mammography (SFM) to full-field digital mammography (FFDM) regarding image quality as well as detectability and characterization of lesions using equivalent images of the same patient acquired with both systems. Two mammography units were used, one with a screen-film system (Senographe DMR) and the other with a digital detector (Senographe 2000D, both GEMS). Screen-film and digital mammograms were performed on 55 patients with cytologically or histologically proven tumors on the same day. Together with these, 75 digital mammograms of patients without tumor and the corresponding previous screen-film mammograms not older than 1.5 years were reviewed by three observers in a random order. Contrast, exposure, and the presence of artifacts were evaluated. Different details, such as the skin, the retromamillary region, and the parenchymal structures, were judged according to a three-point ranking scale. Finally, the detectability of microcalcifications and lesions were compared and correlated to histology. Image contrast was judged to be good in 76%, satisfactory in 20%, and unsatisfactory in 4% of screen-film mammograms. Digital mammograms were judged to be good in 99% and unsatisfactory in 1% of cases. Improper exposure of screen-film system occurred in 18% (10% overexposed and 8% underexposed). Digital mammograms were improperly exposed in 4% of all cases but were of acceptable quality after post-processing. Artifacts, most of them of no significance, were found in 78% of screen-film and in none of the digital mammograms. Different anatomical regions, such as the skin, the retromamillary region, and dense parenchymal areas, were better visualized in digital than in screen-film mammography. All malignant tumors were seen by the three radiologists; however, digital mammograms allowed a better characterization of these lesions to the Breast Imaging Reporting and Data System (BI-RADSZZZ;) categories (FFDM better than

  13. In vivo comparison of screen-film mammography and xeromammography

    International Nuclear Information System (INIS)

    Yagan, R.; Skubic, S.E.; Oravec, D.; Green, H.Y.

    1987-01-01

    In vivo comparison of film-screen with grid and xeromammography was performed in 97 patients by three mammographers experienced with both modalities. The results show that file-screen modality is superior to xeromammography in the following areas: (1) in identifying of microcalcifications and determining their topographic characteristics; (2) in visualizing masses; and (3) in visualizing the nipple and entire skin line without artifacts. Both methods were equal in imaging of the parenchyma of dense breasts. The chest wall is somewhat better visualized with xeromammography, without providing any clinical advantage in the cases reviewed. The authors conclude that film-screen mammography with antiscatter grid is the preferred method in breast evaluation

  14. Screen-film mammography versus full-field digital mammography in a population-based screening program: The Sogn and Fjordane study

    International Nuclear Information System (INIS)

    Juel, Inger-Marie; Johannessen, Gunnar; Skaane, Per; Roth Hoff, Solveig; Hofvind, Solveig

    2010-01-01

    Background: Studies comparing analog and digital mammography in breast cancer screening have shown conflicting results. Little is known about the use of digital photon-counting detectors. Purpose: To retrospectively compare performance indicators in screen-film (SFM) and full-field digital mammography (FFDM) using a photon-counting detector in a population-based screening program. Material and Methods: The Norwegian Social Science Data Services approved the study, which was part of the Norwegian Breast Cancer Screening Program. The program invites women aged 50-69 years to two-view mammography biannually. The study period was January 2005 to June 2006 for SFM and August 2006 to December 2007 for FFDM. Independent double reading was performed using a five-point rating scale for probability of cancer. Recalls due to abnormal mammography were retrospectively reviewed by an expert panel. Performance indicators for the two techniques were compared. Attendance rate was 83.6% (7442/8901) for SFM and 82.0% (6932/8451) for FFDM. Results: The recall rate due to abnormal mammography, cancer detection rate and positive predictive value did not differ significantly between SFM and FFDM: recall 2.3% (174/7442) versus 2.4% (168/6932), cancer detection 0.39% (29/7442) versus 0.48% (33/6932), positive predictive value 16.7% (29/174) versus 19.6% (33/168), respectively (P>0.05 for all). The recall rate due to technically inadequate mammograms was 0.3% (19/7442) for SFM and 0.01% (1/6932) for FFDM. In the retrospective review, a significantly higher proportion of calcifications and asymmetric density were categorized as normal or definitively benign in FFDM compared with SFM. The average glandular dose was 2.17 mGy for SFM and 1.25 mGy for FFDM. Conclusion: Performance indicators show that FFDM using photon-counting detector is suitable for breast cancer screening. The lower radiation dose and lower recalls due to technically inadequate mammograms are of importance in mammography

  15. Magnification mammography: a comparison of full-field digital mammography and screen-film mammography for the detection of simulated small masses and microcalcifications

    International Nuclear Information System (INIS)

    Hermann, K.P.; Obenauer, S.; Funke, M.; Grabbe, E.H.

    2002-01-01

    The objective of this study was a comparison of a full-field digital mammography (FFDM) system and a conventional screen-film mammography (SFM) system with respect to the detectability of simulated small masses and microcalcifications in the magnification mode. All images were obtained using 1.8 times magnification. The FFDM images were obtained at radiation dose levels of 1.39, 1.0, 0.7, 0.49 and 0.24 times that of the SFM images. A contrast-detail phantom was used to compare the detection of simulated lesions using a four alternative forced-choice reader study with three readers. The correct observation ratio (COR) was calculated as the fraction of correctly identified lesions to the total number of simulated lesions. Soft-copy reading was performed for all digital images. Direct magnification images acquired with the digital system showed a lower object contrast threshold than those acquired with the conventional system. For equal radiation dose, the digital system provided a significantly increased COR (0.95) compared with the screen-film system (0.82). For simulated microcalcifications, the corresponding difference was 0.90 to 0.72. The digital system allowed equal detection to screen-film at 40% of the radiation dose used for screen film. Digital magnification images are superior to screen-film magnification images for the detection of simulated small masses and microcalcifications even at a lower radiation dose. (orig.)

  16. Quality control: comparison of images quality with screen film system and digital mammography CR

    International Nuclear Information System (INIS)

    Alvarenga, Frederico L.; Nogueira, Maria do Socorro

    2008-01-01

    The mammography screen film system should be used as part of processing chemicals, revelation process, equipment and this system has have a progressive replacing by the digital technology Full Field Digital Mammography FFDM, Computed Radiography (CR) Mammography and hardcopy. This new acquisition process of medical images has improved radiology section; however it is necessary efficient means for evaluating of the quality parameters. It should be considered taking into account the adaptation of the existent equipment and that procedures adopted for the exam, as well the adaptation of the new mammography films, the radiologist view box constitutes a part of the quality control program. This program aims at obtaining radiography with good quality that allows obtaining more information for the diagnosis and decreases the patient dose. For evaluation the quality image, this article is focused on presenting the differences regarding the acquired images through simulator mammography radiographic PMMA (Poly methyl methacrylate) in CR Mammography system and screen film system. The tests were accomplished at the same equipment of Mammography with the Automatic Exposure Control using a tension of 28 kV for both systems. The quality tests evaluated the spatial resolution, the own structures of the phantom, artifacts, optical density and contrast with conventional and laser films by mammography system. The installation for the accomplishment of the test has a quality control program. The evaluation was based on the pattern developed by the competent organ of the State of Minas Gerais. In this study, it was verified that the suitable Phantom Mama used by the Brazilian School of Radiology for conventional mammography did not obtain satisfactory result for Spatial Resolution in the digital mammography system CR. The final aim of this work is to obtain parameters to characterize the reference phantom quality image in an objective way. These parameters will be used to compare

  17. Does digital mammography in a decentralized breast cancer screening program lead to screening performance parameters comparable with film-screen mammography?

    International Nuclear Information System (INIS)

    Ongeval, Chantal van; Steen, Andre van; Zanca, Federica; Bosmans, Hilde; Marchal, Guy; Putte, Gretel vande; Limbergen, Erik van

    2010-01-01

    To evaluate if the screening performance parameters of digital mammography (DM) in a decentralized screening organization were comparable with film-screen mammography (FSM). A nationwide screening program was launched in 2001, and since 2005 screening with DM has been allowed. Firstly, the parameters of the three regional screening units (RSUs) that first switched to DM (11,355 women) were compared with the FSM period of the same three RSUs (23,325 women). Secondly, they were compared with the results of the whole central breast unit (CBU). The recall rate (RR) of the DM group in the initial round was 2.64% [2.40% for FSM (p = 0.43)] and in the subsequent round 1.20% [1.58% for FSM (p = 0.03)]. The cancer detection rate (CDR) was 0.59% for DM and 0.64% for FSM (p = 0.56). The percentage of ductal carcinoma in situ was 0.07% for DM and 0.16% for FSM (p = 0.02). The positive predictive value was high in the subsequent rounds (DM 48.00%, FSM 45.93%) and lower in the initial round (DM 24.05%, FSM 24.86%). Compared with the results of the whole CBU, DM showed no significant difference. DM can be introduced in a decentralized screening organization with a high CDR without increasing the RR. (orig.)

  18. Comparative evaluation of average glandular dose and image of digital mammography and film mammography in Minas Gerais, Brazil

    International Nuclear Information System (INIS)

    Nogueira, M.; Leyton, F.; Rodrigue, L. L.C.; Oliveira, M.A.; Joana, G.S.; Silva, S.D.

    2015-01-01

    Breast cancer is the most common cancer among women, and early detection is critical to its diagnosis and treatment. Mammography is the best method for breast-cancer screening and is capable of reducing mortality rates To date, the most effective method for early detection of breast cancer has been x-ray mammography for which the screen/film (SF) technique has been the gold standard. Digital mammography has been proposed as a substitute for film mammography given the benefits inherent to digital technology. The purpose of our study was to compare the technical performance of digital mammographic and screen-film mammography. A PMMA phantom with objects to simulate breast structures. For the screen/film (SF) technique the results showed that 54% mammography units did not achieve the minimum acceptable performance as far the image quality. Besides, 67% services showed inadequate performance in their processing systems, which had significant influence on the image quality. At the mean glandular dose only 44% of digital systems evaluated were compliant in all thicknesses of PMMA. The average glandular dose AGD was 90 % higher than in screen/film systems. (authors)

  19. Comparison of Diagnostic Accuracy of Breast Masses Using Digitized Images Versus Screen-Film Mammography

    International Nuclear Information System (INIS)

    Zhigang Liang; Xiangying Du; Jiabin Liu; Xinyu Yao; Yanhui Yang; Kuncheng Li

    2008-01-01

    Background: Medical film digitizers play an important transitory role as digital-analogue bridges in radiology. Digitized mammograms require evaluation of performance to assure medical image quality. Purpose: To compare the diagnostic accuracy in the interpretation of breast masses using original screen-film mammograms versus digitized images. Material and Methods: A total of 72 female patients between 55 and 81 years of age suspected of having breast cancer were selected by two non-observing radiologists. Of these, 31 cases were benign lesions and 41 cases were cancer. The mammography films were digitized using a laser film digitizer. Three radiologists, each with more than 10 years of experience in mammography, interpreted the screen-film mammograms and digitized images respectively. The time interval was 4 weeks. A four-point malignancy scale was used, with 1 defined as definitely not malignant, 2 as probably not malignant, 3 as probably malignant, and 4 as definitely malignant. Receiver operating characteristic (Roc) curves, sensitivity, and specificity were compared. Results: The average area-under-the-curve (Az) value of the original screen-film mammograms was 0.921, and the average Az value of the digitized images was 0.859. This difference was not statistically significant (P=0.131). The detection specificity of extremely dense breasts was lower than that for other breast compositions for both digitized images and screen-film mammograms. No statistical significance in sensitivity and specificity was observed between digitized images and mammograms for each breast composition. Original screen-film mammograms were observed to perform better than digitized images. Conclusion: Digitized images with a spatial resolution of 175 μm can be used instead of screen-film mammograms in the diagnosis of breast cancer

  20. Quality assurance programme for screen film mammography

    International Nuclear Information System (INIS)

    2009-01-01

    The application of radiation in human health, for both the diagnosis and treatment of disease, is an important component of the work of the IAEA. In the area of diagnostic radiology, this work is focused on quality assurance methods to both the promotion of the effective use of radiation for diagnostic outcome, through achieving and maintaining appropriate image quality, and also on dose determination to allow the monitoring and reduction of dose to the patient. In response to heightened awareness of the importance of patient dose contributed by radiology procedures, the IAEA published Dosimetry in Diagnostic Radiology: An International Code of Practice (Technical Reports Series No. 457) in 2007, to form a basis for patient dose determination for the Member States. Further to this, it is recognized that for complex diagnostic procedures, such as mammography, a detailed guidance document is required to give the professionals in the clinical centre the knowledge necessary to assess the patient dose, as well as to ensure that the procedure gives the maximal patient benefit possible. It is well documented that without the implementation of a quality culture and a systematic quality assurance programme with appropriate education, the detection of breast cancer cannot be made at an early enough stage to allow effective curative treatment to be undertaken. Currently there are a number of established quality assurance protocols in mammography from national and regional institutions, however, many of these protocols are distinctive and so a harmonized approach is required. This will allow the Member States to facilitate quality assurance in mammography in a standardized way which will also facilitate the introduction of national quality assurance programmes that are needed to underpin effective population screening programmes for breast cancer. Development of a quality assurance document for screen film mammography was started in 2005 with the appointment of a drafting

  1. Mammography with rare earth intensifying screens

    International Nuclear Information System (INIS)

    Maurer, H.J.; Goos, F.

    1987-01-01

    Screens basing on rare earth phosphors with suitable films green or blue sensitive may be used in mammography with grids without diagnostic losses. Highest definition will be obtained with medium densities on film. High-speed screens may reduce dose, but definition is poor. Best compromise between speed and high definition may be reached with relative low thickness of phosphor layers. A system of high definition films (Medichrome) and special rare earth screens give best results. (orig.) [de

  2. Clinical evaluation of mammography using a screen-film system. Pt. 3

    International Nuclear Information System (INIS)

    Wurm, J.; Behrends, E.; Hofmann-Preiss, K.; Paterok, E.M.; Saebel, M.; Weishaar, J.

    1983-01-01

    In a clinical image quality test, the parameter image quality is analysed using the ROC method and on the basis of mammograms already classified by means of histological findings into ''benign'' and ''malignant'' cases. The results of this analysis confirmed those of the first two studies: The screen-film system, due to its almost equally good image quality, achieves a diagnostic accuracy as good as the Definix test film without screen. In addition, the following two parameters have been investigated in this clinical test: Different knowledge and experience of the evaluating experts in the field of mammography, and the learning progress in the course of expert training. The difference in knowledge and experience of the various evaluators becomes apparent in ROC analysis only with an evaluator having much more experience than the others in the field of mammography. The parameter learning progress - as shown by repeating the evaluation after three months of intensive training - does not come forth clear enough in the ROC curves. An analysis of the frequency distribution of the five decision thresholds reveals the approach of the individual evaluator. (orig.) [de

  3. Experimental investigations of image quality in X-ray mammography with conventional screen film system (SFS), digital phosphor storage plate in/without magnification technique (CR) and digital CCD-technique (CCD)

    International Nuclear Information System (INIS)

    Schulz-Wendtland, R.; Aichinger, U.; Boehner, C.; Dobritz, M.; Wenkel, E.; Bautz, W.; Saebel, M.

    2001-01-01

    Comparison of image quality in X-ray mammography between conventional film screen film system (SFS), digital phosphor storage plate in and without magnification technique (CR) and digital CCD-technique (CCD). Radiograms of an RMI-mammography phantom were acquired using a conventional screen film system, three digital storage plate systems and two digital systems in CCD-technique. Additionally the radiograms of one digital phosphor storage plate system were post-processed regarding contrast and included in the comparison. The detectability of details was best with the digital mammography in CCD-technique. After confirming these promising results in clinical studies, digital mammography should be able to replace conventional screen film technique. (orig.)

  4. Interval breast cancer characteristics before, during and after the transition from screen-film to full-field digital screening mammography.

    Science.gov (United States)

    van Bommel, Rob M G; Weber, Roy; Voogd, Adri C; Nederend, Joost; Louwman, Marieke W J; Venderink, Dick; Strobbe, Luc J A; Rutten, Matthieu J C; Plaisier, Menno L; Lohle, Paul N; Hooijen, Marianne J H; Tjan-Heijnen, Vivianne C G; Duijm, Lucien E M

    2017-05-05

    To determine the proportion of "true" interval cancers and tumor characteristics of interval breast cancers prior to, during and after the transition from screen-film mammography screening (SFM) to full-field digital mammography screening (FFDM). We included all women with interval cancers detected between January 2006 and January 2014. Breast imaging reports, biopsy results and breast surgery reports of all women recalled at screening mammography and of all women with interval breast cancers were collected. Two experienced screening radiologists reviewed the diagnostic mammograms, on which the interval cancers were diagnosed, as well as the prior screening mammograms and determined whether or not the interval cancer had been missed on the most recent screening mammogram. If not missed, the cancer was considered an occult ("true") interval cancer. A total of 442 interval cancers had been diagnosed, of which 144 at SFM with a prior SFM (SFM-SFM), 159 at FFDM with a prior SFM (FFDM-SFM) and 139 at FFDM with a prior FFDM (FFDM-FFDM). The transition from SFM to FFDM screening resulted in the diagnosis of more occult ("true") interval cancers at FFDM-SFM than at SFM-SFM (65.4% (104/159) versus 49.3% (71/144), P screened digitally for the second time (57.6% (80/139) at FFDM-FFDM versus 49.3% (71/144) at SFM-SFM). Tumor characteristics were comparable for the three interval cancer cohorts, except of a lower porportion (75.7 and 78.0% versus 67.2% af FFDM-FFDM, P cancers at FFDM with prior FFDM. An increase in the proportion of occult interval cancers is observed during the transition from SFM to FFDM screening mammography. However, this increase seems temporary and is no longer detectable after the second round of digital screening. Tumor characteristics and type of surgery are comparable for interval cancers detected prior to, during and after the transition from SFM to FFDM screening mammography, except of a lower proportion of invasive ductal cancers after the

  5. Film quality in film mammography. Pt. 2

    International Nuclear Information System (INIS)

    Friedrich, M.; Weskamp, P.; Freie Univ. Berlin

    1976-01-01

    During consideration of three film mammographic systems, the concept of signal/noise ratio is developed as a quantitative measure of film quality. The ability to recognise detail related to detail size, film blackening and exposure geometry was studied for various systems, and the quality profiles are discussed. There is a considerable difference in quality between industrial films without screens and film-screen combinations; however, exposure geometry during mammography has a considerable effect which tends to reduce the difference. Consequently, detail sizes of 200 μ to 1,000 μ (including the majority of mammographic micro-calcifications) are shown about equally well. Contrast for the lo-dose system is somewhat less than for adequately exposed industrial film. Over-exposure with the lo-dose system, contrary to industrial film, rapidly leads to unsatisfactory results. On the other hand it is often not possible to obtain an adequate exposure when using industrial film. For these reasons it is often an advantage to examine large breasts and the dense breasts of young women with a film-screen combination which requires approximately one eighth of the dose necessary for industrial film. For small or easily compressable breasts best results are obtained, using an adequate exposure by employing industril film; radiation dose it then acceptable. (orig./ORU) [de

  6. Visibility of microcalcifications in computed and screen-film mammography

    International Nuclear Information System (INIS)

    Cowen, Arnold R.; Launders, Jason H.; Jadav, Mark; Brettle, David S.

    1997-01-01

    Due to the clinically and technically demanding nature of breast x-ray imaging, mammography still remains one of the few essentially film-based radiological imaging techniques in modern medical imaging. There are a range of possible benefits available if a practical and economical direct digital imaging technique can be introduced to routine clinical practice. There has been much debate regarding the minimum specification required for direct digital acquisition. One such direct digital system available is computed radiography (CR), which has a modest specification when compared with modern screen-film mammography (SFM) systems. This paper details two psychophysical studies in which the detection of simulated microcalcifications with CR has been directly compared to that with SFM. The first study found that under scatter-free conditions the minimum detectable size of micro calcification was approximately 130 μm for both SFM and CR. The second study found that SFM had a 4.6% higher probability of observers being able to correctly identify the shape of 350 μm diameter test details; there was no significant difference for either larger or smaller test details. From the results of these studies it has been demonstrated that the modest specification of CR, in terms of limiting resolution, does not translate into a dramatic difference in the perception of details at the limit of detectability. When judging the imaging performance of a system it is more important to compare the signal-to-noise ratio transfer spectrum characteristics, rather than simply the modulation transfer function. (author)

  7. Comparing the visualization of microcalcifications with direct magnification in digital full-field mammography vs. film-screen mammography

    International Nuclear Information System (INIS)

    Diekmann, F.; Diekmann, S.; Rogalla, P.; Hamm, B.; Bick, U.; Blohmer, J.U.; Winzer, K.J.

    2002-01-01

    Purpose: To evaluate the conspicuity of microcalcifications in magnified mammographic views of preparations obtained with full field digital mammography (FFDM), film-screen mammography (FSM), and the DIMA technique. Material and Methods: Twelve preparations were examined by FFDM and FSM using 1.8 x magnification and DIMA using 7 x magnification. Parameter settings were identical for all three techniques. The number of visible microcalcifications was then determined for each modality by three radiologists. As far as possible, all preparations were X-rayed at 22 kV and 10 mAS. Results: Altogether 9705 calcifications were counted (DIMA: 1609/1542/1534; FFDM: 1020/753/881; FSM: 901/643/822). The total number of microcalcifications identified with the DIMA technique was 4685 as compared to 2654 with FFDM and 2366 with FSM. The calcifications counted with FFDM and FSM thus corresponded to 56.6% and 50.5%, respectively, of those identified with DIMA. The differences between the groups were statistically significant (F-Test, p [de

  8. Differences in radiological patterns, tumour characteristics and diagnostic precision between digital mammography and screen-film mammography in four breast cancer screening programmes in Spain

    International Nuclear Information System (INIS)

    Domingo, Laia; Sala, Maria; Romero, Anabel; Belvis, Francesc; Macia, Francesc; Castells, Xavier; Sanchez, Mar; Ferrer, Joana; Salas, Dolores; Ibanez, Josefa; Vega, Alfonso; Ferrer, Francesc; Laso, M.S.

    2011-01-01

    To compare tumour characteristics between cancers detected with screen-film mammography (SFM) and digital mammography (DM) and to evaluate changes in positive predictive values (PPVs) for further assessments, for invasive procedures and for distinct radiological patterns in recalled women. 242,838 screening mammograms (171,191 SFM and 71,647 DM) from 103,613 women aged 45-69 years, performed in four population-based breast cancer screening programmes in Spain, were included. The tumour characteristics and PPVs of each group were compared. Radiological patterns (masses, calcifications, distortions and asymmetries) among recalled women were described and PPVs were evaluated. The percentages of ductal carcinoma in situ (DCIS) were higher in DM than in SFM both in the first [18.5% vs. 15.8%(p = 0.580)] and in successive screenings [23.2% vs. 15.7%(p = 0.115)]. PPVs for masses, asymmetries and calcifications were higher in DM, being statistically significant in masses (5.3% vs. 3.9%; proportion ratio: 1.37 95%CI: 1.08-1.72). Among cancers detected by calcifications, the percentage of DCIS was higher in DM (60.3% vs. 46.4%, p = 0.060). PPVs were higher when DM was used, both for further assessments and for invasive procedures, with similar cancer detection rates and no statistically significant differences in tumour characteristics. The greatest improvements in PPVs were found for masses. (orig.)

  9. Differences in radiological patterns, tumour characteristics and diagnostic precision between digital mammography and screen-film mammography in four breast cancer screening programmes in Spain

    Energy Technology Data Exchange (ETDEWEB)

    Domingo, Laia; Sala, Maria [IMIM-Hospital del Mar, Department of Epidemiology and Evaluation, Barcelona (Spain); CIBER de Epidemiologia y Salud Publica (CIBERESP), Barcelona (Spain); Universitat Autonoma de Barcelona (UAB), EHEA Doctoral Program in Public Health. Department of Pediatrics, Obstetrics and Gynecology, Preventive Medicine and Public Health, Barcelona (Spain); Romero, Anabel; Belvis, Francesc; Macia, Francesc; Castells, Xavier [IMIM-Hospital del Mar, Department of Epidemiology and Evaluation, Barcelona (Spain); CIBER de Epidemiologia y Salud Publica (CIBERESP), Barcelona (Spain); Sanchez, Mar [Government of Cantabria, General Directorate of Public Health, Department of Health, Santander (Spain); Ferrer, Joana [Radiology Unit. Hospital Santa Caterina, Girona (Spain); Salas, Dolores; Ibanez, Josefa [General Directorate Public Health and Centre for Public Health Research (CSISP), Valencia (Spain); Vega, Alfonso [Hospital Universitario Marques de Valdecilla, Radiology Unit, Santander (Spain); Ferrer, Francesc [Hospital del Mar, Radiology and Nuclear Medicine Service, Barcelona (Spain); Laso, M.S. [Breast Cancer Screening Unit Burjassot, Valencia (Spain)

    2011-09-15

    To compare tumour characteristics between cancers detected with screen-film mammography (SFM) and digital mammography (DM) and to evaluate changes in positive predictive values (PPVs) for further assessments, for invasive procedures and for distinct radiological patterns in recalled women. 242,838 screening mammograms (171,191 SFM and 71,647 DM) from 103,613 women aged 45-69 years, performed in four population-based breast cancer screening programmes in Spain, were included. The tumour characteristics and PPVs of each group were compared. Radiological patterns (masses, calcifications, distortions and asymmetries) among recalled women were described and PPVs were evaluated. The percentages of ductal carcinoma in situ (DCIS) were higher in DM than in SFM both in the first [18.5% vs. 15.8%(p = 0.580)] and in successive screenings [23.2% vs. 15.7%(p = 0.115)]. PPVs for masses, asymmetries and calcifications were higher in DM, being statistically significant in masses (5.3% vs. 3.9%; proportion ratio: 1.37 95%CI: 1.08-1.72). Among cancers detected by calcifications, the percentage of DCIS was higher in DM (60.3% vs. 46.4%, p = 0.060). PPVs were higher when DM was used, both for further assessments and for invasive procedures, with similar cancer detection rates and no statistically significant differences in tumour characteristics. The greatest improvements in PPVs were found for masses. (orig.)

  10. Comparison of screen-film and full-field digital mammography in Japanese population-based screening

    International Nuclear Information System (INIS)

    Yamada, Takayuki; Saito, Mioko; Ishibashi, Tadashi

    2004-01-01

    The purpose of this study was to investigate how the greater contrast of full-field digital mammography (FFDM) affects the detection of suspicious lesions in Japanese population-based screening. Screen-film mammography (SFM) and FFDM were performed in 480 women aged 50 years or more. A set of mediolateral oblique views was obtained with each modality. All mammograms were independently double-read. The five-scale category assessment and type of finding using the Breast Imaging Reporting and Data System (BIRADS) nomenclature were given. Intraobserver variance, recall rates, and positive predictive value were calculated. The findings between the two modalities were discordant. κ-values for each reader were 0.619 and 0.385, respectively. Almost half of the microcalcifications were called with both modalities. The detection of masses was less concordant between the readers (27%). The masses were detected more frequently with FFDM (73%). Other findings were only detected with one modality. The recall rate was not significantly different (2.9% with SFM vs. 4.2% with FFDM; p=0.253). The positive predictive value was not significantly different (14% with SFM vs. 10% with FFDM; p=0.69), either. Two patients with breast cancer were detected with both modalities. Recall rates and positive predictive value were not significantly different between SFM and FFDM. Cancers were detected with both modalities. (author)

  11. The mammography screening employee inreach program.

    Science.gov (United States)

    Robinson, Joanne; Seltzer, Vicki; Lawrence, Loretta; Autz, George; Kostroff, Karen; Weiselberg, Lora; Colagiacomo, Maria

    2007-02-01

    To determine whether our health care employees were undergoing mammography screening according to American Cancer Society guidelines and to determine whether aggressive outreach, education and streamlining of mammography scheduling could improve compliance. All female employees at North Shore University Hospital (NSUH) and several other health system facilities (SF) were sent mailings to their homes that included breast health education and mammography screening guidelines, a questionnaire regarding their own mammography screening history and the opportunity to have their mammography screening scheduled by the Mammography Screening Employee Inreach Program (MSEIP) coordinator. Of the approximately 2,700 female employees aged 40 and over at NSUH and SF, 2,235 (82.7%) responded to the questionnaire, and 1,455 had a mammogram done via the MSEIP. Of the 1,455, 43% either were overdue for a mammogram or had never had one. During a second year of the MSEIP at NSUH and SF, an additional 1,706 mammograms were done. People employed in health care jobs do not necessarily avail themselves of appropriate health care screening. An aggressive program that utilized education, outreach and assistance with scheduling was effective in increasing compliance with mammography screening.

  12. Digital mammography in a screening programme and its implications for pathology: a comparative study.

    LENUS (Irish Health Repository)

    Feeley, Linda

    2011-03-01

    Most studies comparing full-field digital mammography (FFDM) with conventional screen-film mammography (SFM) have been radiology-based. The pathological implications of FFDM have received little attention in the literature, especially in the context of screening programmes. The primary objective of this retrospective study is to compare FFDM with SFM in a population-based screening programme with regard to a number of pathological parameters.

  13. One more hurdle to increasing mammography screening: pubescent, adolescent, and prior mammography screening experiences.

    Science.gov (United States)

    Thomas, Eileen; Usher, LaToya

    2009-01-01

    Approximately $8.1 billion dollars is spent each year in the United States alone on the treatment of breast cancer. Survival rates are dependent on access to, and utilization of, early detection services. The primary reason for disparity in breast cancer mortality is the delay in time to diagnosis, resulting in poor prognosis. Despite ongoing research to understand barriers to mammography screening, recent studies report a decrease in mammography screening among all racial groups. A qualitative approach was used to elicit information from 36 White non- Hispanic, African-American, Hispanic, and Native American women without a history of breast cancer. Women were invited to share written or audiotape-recorded narratives about experiences pertaining to their breasts and their mammography screening experiences. Major categories identified were: teasing, family norms and values, media/societal influence, body image, and mammography screening experiences. The resulting effects of these experiences left these women with feelings of shame and "conflict" regarding their breasts. The major theme identified was breast conflict. Findings suggest that breast conflict may persist throughout the lifespan and can have a negative influence on a woman's decision to participate in mammography screening. The authors hypothesize that experiences that occur during adolescence pertaining to young girls' breasts can influence a women's body image, which in turn can later in life affect health-seeking behaviors related to mammography screening. These findings have implications for public health practice in planning for breast cancer screening, education, and interventions for women from diverse racial/ethnics groups.

  14. Breast dose variability in a bi-racial population undergoing screening mammography

    International Nuclear Information System (INIS)

    Schubauer-Berigan, M.K.; Baron, L.; Frey, G.D.; Hoel, D.G.

    2002-01-01

    This study evaluated individual and population dose variability during screening mammography among 570 white and black women in South Carolina, USA. Aspects of dosimetry that were considered include compressed breast thickness (CBT), number of films per screening session, and dose in previous or subsequent sessions. Breast dose was log-normally distributed in the population, with a geometric mean of 6.6 mGy per session. Doses were significantly higher for black women, for women with high CBT or who receive more than two views per breast, and for the mediolateral oblique, compared to the craniocaudal view. No relationship was observed between age and dose. Total dose per breast varied by a factor of 20 across the study population, but the individual's dose varied little among repeat screening sessions, especially after adjusting for the number of films received per session. These results may inform assessments of the projected risks of inducing breast cancer from screening mammography. (author)

  15. Baseline Screening Mammography: Performance of Full-Field Digital Mammography Versus Digital Breast Tomosynthesis.

    Science.gov (United States)

    McDonald, Elizabeth S; McCarthy, Anne Marie; Akhtar, Amana L; Synnestvedt, Marie B; Schnall, Mitchell; Conant, Emily F

    2015-11-01

    Baseline mammography studies have significantly higher recall rates than mammography studies with available comparison examinations. Digital breast tomosynthesis reduces recalls when compared with digital mammographic screening alone, but many sites operate in a hybrid environment. To maximize the effect of screening digital breast tomosynthesis with limited resources, choosing which patient populations will benefit most is critical. This study evaluates digital breast tomosynthesis in the baseline screening population. Outcomes were compared for 10,728 women who underwent digital mammography screening, including 1204 (11.2%) baseline studies, and 15,571 women who underwent digital breast tomosynthesis screening, including 1859 (11.9%) baseline studies. Recall rates, cancer detection rates, and positive predictive values were calculated. Logistic regression estimated the odds ratios of recall for digital mammography versus digital breast tomosynthesis for patients undergoing baseline screening and previously screened patients, adjusted for age, race, and breast density. In the baseline subgroup, recall rates for digital mammography and digital breast tomosynthesis screening were 20.5% and 16.0%, respectively (p = 0.002); digital breast tomosynthesis screening in the baseline subgroup resulted in a 22% reduction in recall compared with digital mammography, or 45 fewer patients recalled per 1000 patients screened. Digital breast tomosynthesis screening in the previously screened patients resulted in recall reduction of 14.3% (p tomosynthesis than from digital mammography alone.

  16. A comparison of digital and screen-film mammography using quality control phantoms

    International Nuclear Information System (INIS)

    Undrill, Peter E.; O'Kane, Arlene D.; Gilbert, Fiona J.

    2000-01-01

    AIM: To compare the performance of a direct digital mammography system with normal-view and magnified-view conventional screen-film methods using quality control phantoms. MATERIALS AND METHODS: Using a Siemens Mammomat [reg] 3000 and an Opdima [reg] digital spot imaging and biopsy attachment, film and direct digital images of two phantoms [DuPont and TOR (MAM)] were obtained under normal operating conditions. These were assessed by three groups of observers with differing expertise -- radiologists, radiographers and medical physicists. Each observer was asked to compare the direct digital image with films taken in standard view and magnified view, providing scores for object visibility and confidence. For the digital images, observers were allowed to vary the image presentation parameters. RESULTS: Both phantoms showed that overall the direct digital view and the magnified view film performed significantly better (P < 0.05) than standard view film. For certain small or low contrast objects the differences became very highly significant (P < 0.001). CONCLUSION: Only the TOR (MAM) phantom showed any significant difference between digital and magnified modalities, with magnified views performing better for fine, faint filaments and digital acquisition better for low contrast objects. Almost no difference existed between the three observer groups. Undrill, P.E. (2000). Clinical Radiology 53, 782-790

  17. Organisational aspects of mammography screening in digital settings: First experiences of Luxembourg

    International Nuclear Information System (INIS)

    Shannoun, F.; Schanck, J. M.; Scharpantgen, A.; Wagnon, M. C.; Ben Daoud, M.; Back, C.

    2008-01-01

    Luxembourg has been conducting a breast cancer screening programme since 1992, like a large number of other European countries, as early detection and treatment of breast cancer have been proven to reduce mortality. The majority of these screening programmes are based on analogue X-ray technology and have optimised their organisation of transporting, archiving and reading with respect to films. Last decade is marked by enormous developments in digital mammography. Different technologies such as flat panel-, computed radiography- and scanning systems became available. Digital mammography is expected to have a major impact on quality and organisation of breast cancer screening programmes. Screening programmes are now faced with a huge challenge of incorporating the digital technology, including implementation of electronic image exchange, conception of new electronic work-flow, establishing adapted quality assurance programmes and training of radiologists and technical personnel. Initial experiences of the Luxembourg approach in organising digital mammography screening and its quality assurance are reported. (authors)

  18. Does gender discrimination impact regular mammography screening? Findings from the race differences in screening mammography study.

    Science.gov (United States)

    Dailey, Amy B; Kasl, Stanislav V; Jones, Beth A

    2008-03-01

    ABSTRACT Objective: To determine if gender discrimination, conceptualized as a negative life stressor, is a deterrent to adherence to mammography screening guidelines. African American and white women (1451) aged 40-79 years who obtained an index screening mammogram at one of five urban hospitals in Connecticut between October 1996 and January 1998 were enrolled in this study. This logistic regression analysis includes the 1229 women who completed telephone interviews at baseline and follow-up (average 29.4 months later) and for whom the study outcome, nonadherence to age-specific mammography screening guidelines, was determined. Gender discrimination was measured as lifetime experience in seven possible situations. Gender discrimination, reported by nearly 38% of the study population, was significantly associated with nonadherence to mammography guidelines in women with annual family incomes of > or =$50,000 (OR 1.99, 95% CI 1.33, 2.98) and did not differ across racial/ethnic group. Our findings suggest that gender discrimination can adversely influence regular mammography screening in some women. With nearly half of women nonadherent to screening mammography guidelines in this study and with decreasing mammography rates nationwide, it is important to address the complexity of nonadherence across subgroups of women. Life stressors, such as experiences of gender discrimination, may have considerable consequences, potentially influencing health prevention prioritization in women.

  19. Efficacy of storage phosphor-based digital mammography in diagnosis of breast cancer

    International Nuclear Information System (INIS)

    Kitahama, Hiroyuki

    1991-01-01

    The aim of this study is to present efficacy of storage phosphor-based digital mammography (CR-mammography) in diagnosis of breast cancer. Ninety-seven cases with breast cancer including 44 cases less than 2 cm in macroscopic size (t1 cases) were evaluated using storage phosphor-based digital mammography (2000 x 2510 pixels by 10 bits). Abnormal findings on CR-mammography were detected in 86 cases (88.7%) of 97 women with breast cancer. Sensitivity of CR-mammography was 88.7%. It was superior to that of film-screen mammography. On t1 breast cancer cases, sensitivity on CR-mammography was 88.6%. False negative rate in t1 breast cancer cases was reduced by image processing using CR-mammography. To evaluate microcalcifications, CR-mammograms and film-screen mammograms were investigated in 22 cases of breast cancer proven pathologically the existence of microcalcifications and 11 paraffin tissue blocks of breast cancer. CR-mammography was superior to film-screen mammography in recognizing of microcalcifications. As regards the detectability for the number and the shape of microcalcifications, CR-mammography was equivalent to film-screen mammography. Receiver operating characteristic (ROC) analysis by eight observers was performed for CR-mammography and film-screen mammography with 54 breast cancer patients and 54 normal cases. The detectability of abnormal findings of breast cancer on CR-mammography (ROC area=0.91) was better than that on film-screen mammography (ROC area=0.88) (p<0.05). Efficacy of storage phosphor-based digital mammography in diagnosis of breast cancer was discussed and demonstrated in this study. (author)

  20. Cost-effectiveness of increasing access to mammography through mobile mammography for older women.

    Science.gov (United States)

    Naeim, Arash; Keeler, Emmett; Bassett, Lawrence W; Parikh, Jay; Bastani, Roshan; Reuben, David B

    2009-02-01

    To compare the costs of mobile and stationary mammography and examine the incremental cost-effectiveness of using mobile mammography to increase screening rates. A cost-effectiveness analysis was performed using effectiveness data from a randomized clinical trial and modeling of costs associated with the mobile mammography intervention. The trial involved 60 community-based meal sites, senior centers, and clubs. Four hundred ninety-nine individuals were enrolled in the study, of whom 463 had outcome data available for analysis. Costs were calculated for stationary and mobile mammography, as well as costs due to differences in technology and film versus digital. Incremental cost-effectiveness (cost per additional screen) was modeled, and sensitivity analysis was performed by altering efficiency (throughput) and effectiveness based on subgroup data from the randomized trial. The estimated annual costs were $435,162 for a stationary unit, $539,052 for a mobile film unit, and $456, 392 for a mobile digital unit. Assuming mobile units are less efficient (50% annual volume), the cost per screen was $41 for a stationary unit, $86 for a mobile film unit, and $102 for a mobile digital unit. The incremental cost per additional screen were $207 for a mobile film unit and $264 for a mobile digital unit over a stationary unit. Although mobile mammography is a more effective way to screen older women, the absolute cost per screen of mobile units is higher, whereas the reimbursement is no different. Financial barriers may impede the widespread use of this approach.

  1. Quality control for the mammography screening program in Serbia: Physical and technical aspects

    International Nuclear Information System (INIS)

    Ciraj-Bjelac, O.; Bozovic, P.; Lazarevic, D.; Arandjic, D.; Kosutic, D.

    2012-01-01

    Breast cancer is the major cause of mortality among female population in Serbia. It is presumed that the introduction of screening programme will reduce mortality and therefore, 47 new mammography units were installed for the purpose of population-based screening program in 2011. In parallel, Quality assurance and Quality control (QC) in mammography has received increasing attention as an essential element of the successful breast cancer campaign that is for the first time initialed in Serbia. The purpose of this study is to investigate the need for and the possible implementation of the comprehensive QC programme for the mammography screening in Serbia, with special focus on physical and technical aspect. In the first phase, a QC protocols containing list of parameters, methodology, frequency of tests and reference values for screen-film, computed radiography and full-filed digital mammography) units, were developed. The second phase is focused on the initial implementation of these protocols. The paper presents results of tests of the selected parameters in 35 mammography units, with special emphasis on patient dose and image quality descriptors. After initial implementation at the beginning of the population based breast cancer screening campaign, it is essential to establish system of regular and periodic QC equipment monitoring and to ensure high quality mammograms with minimal possible radiation dose to population included in the screening. (authors)

  2. Mammography - recent technical developments and their clinical potential

    Energy Technology Data Exchange (ETDEWEB)

    Hemdal, Bengt; Mattsson, Soeren [Malmoe Univ. Hospital (Sweden). Dept. of Radiation Physics; Andersson, Ingvar [Malmoe Univ. Hospital (Sweden). Dept. of Diagnostic Radiology; Thilander Klang, Anne [Sahlgrenska Univ. Hospital, Goeteborg (Sweden). Dept. of Medical Physics and Biomedical Engineering; Bengtsson, Gert; Jarlman, O. [Lund Univ. Hospital (Sweden). Dept. of Diagnostic Radiology; Leitz, Wolfram [Swedish Radiation Protection Authority, Stockholm (Sweden); Bjurstam, Nils [Univ. of North Norway, Troms (Norway). Dept. of Radiology

    2002-05-01

    The recent technical developments in digital as well as screen-film X-ray mammography have been reviewed in order to evaluate their clinical potential and to analyse possible lines for future development. Material and methods: The scientific literature has been reviewed, conferences covered and contacts with colleagues developed. Companies in the field have been inquired and invited for presentations. Own experience has been gathered from different screen-film and digital mammography systems. Results and conclusions: Although there are important complementary techniques such as ultrasound and magnetic resonance imaging (MRI), X-ray mammography is still the golden standard for breast imaging. It is relatively simple and cost-effective, and it is presently the only realistic technique for screening in a large scale. It is still largely the only technique that can detect breast cancer in a pre invasive stage. Equipment for digital mammography is commercially available both with small area and full field technique (FFDM). The development of FFDM systems is now intense, as well as the development of dedicated workstations and computer-aided detection (CAD). In spite of this, the introduction of digital mammography has been very slow compared to most other X-ray examinations due to high costs and technical challenges to meet the high demands on image quality and dose in mammography as well as the demands on specialised workflow support for screening mammography and suitable display techniques. Film reading of digital mammograms has been the most common display mode so far, but to take full advantage of the digital concept, diagnostic as well as logistic, monitor reading must be applied. There is a potential of FFDM systems for significantly higher image quality or significantly lower dose than screen-film mammography (SFM), or both. Further research is necessary to fully use this potential. The investment costs are much higher for digital than screen-film mammography

  3. Mammography - recent technical developments and their clinical potential

    International Nuclear Information System (INIS)

    Hemdal, Bengt; Mattsson, Soeren; Bjurstam, Nils

    2002-05-01

    The recent technical developments in digital as well as screen-film X-ray mammography have been reviewed in order to evaluate their clinical potential and to analyse possible lines for future development. Material and methods: The scientific literature has been reviewed, conferences covered and contacts with colleagues developed. Companies in the field have been inquired and invited for presentations. Own experience has been gathered from different screen-film and digital mammography systems. Results and conclusions: Although there are important complementary techniques such as ultrasound and magnetic resonance imaging (MRI), X-ray mammography is still the golden standard for breast imaging. It is relatively simple and cost-effective, and it is presently the only realistic technique for screening in a large scale. It is still largely the only technique that can detect breast cancer in a pre invasive stage. Equipment for digital mammography is commercially available both with small area and full field technique (FFDM). The development of FFDM systems is now intense, as well as the development of dedicated workstations and computer-aided detection (CAD). In spite of this, the introduction of digital mammography has been very slow compared to most other X-ray examinations due to high costs and technical challenges to meet the high demands on image quality and dose in mammography as well as the demands on specialised workflow support for screening mammography and suitable display techniques. Film reading of digital mammograms has been the most common display mode so far, but to take full advantage of the digital concept, diagnostic as well as logistic, monitor reading must be applied. There is a potential of FFDM systems for significantly higher image quality or significantly lower dose than screen-film mammography (SFM), or both. Further research is necessary to fully use this potential. The investment costs are much higher for digital than screen-film mammography

  4. Digital mammography; Mamografia digital

    Energy Technology Data Exchange (ETDEWEB)

    Chevalier, M.; Torres, R.

    2010-07-01

    Mammography represents one of the most demanding radiographic applications, simultaneously requiring excellent contrast sensitivity, high spatial resolution, and wide dynamic range. Film/screen is the most widely extended image receptor in mammography due to both its high spatial resolution and contrast. The film/screen limitations are related with its narrow latitude, structural noise and that is at the same time the medium for the image acquisition, storage and presentation. Several digital detector made with different technologies can overcome these difficulties. Here, these technologies as well as their main advantages and disadvantages are analyzed. Also it is discussed its impact on the mammography examinations, mainly on the breast screening programs. (Author).

  5. Comparison of tomosynthesis plus digital mammography and digital mammography alone for breast cancer screening.

    Science.gov (United States)

    Haas, Brian M; Kalra, Vivek; Geisel, Jaime; Raghu, Madhavi; Durand, Melissa; Philpotts, Liane E

    2013-12-01

    To compare screening recall rates and cancer detection rates of tomosynthesis plus conventional digital mammography to those of conventional digital mammography alone. All patients presenting for screening mammography between October 1, 2011, and September 30, 2012, at four clinical sites were reviewed in this HIPAA-compliant retrospective study, for which the institutional review board granted approval and waived the requirement for informed consent. Patients at sites with digital tomosynthesis were offered screening with digital mammography plus tomosynthesis. Patients at sites without tomosynthesis underwent conventional digital mammography. Recall rates were calculated and stratified according to breast density and patient age. Cancer detection rates were calculated and stratified according to the presence of a risk factor for breast cancer. The Fisher exact test was used to compare the two groups. Multivariate logistic regression was used to assess the effect of screening method, breast density, patient age, and cancer risk on the odds of recall from screening. A total of 13 158 patients presented for screening mammography; 6100 received tomosynthesis. The overall recall rate was 8.4% for patients in the tomosynthesis group and 12.0% for those in the conventional mammography group (P tomosynthesis reduced recall rates for all breast density and patient age groups, with significant differences (P tomosynthesis versus 5.2 per 1000 in patients receiving conventional mammography alone (P = .70). Patients undergoing tomosynthesis plus digital mammography had significantly lower screening recall rates. The greatest reductions were for those younger than 50 years and those with dense breasts. A nonsignificant 9.5% increase in cancer detection was observed in the tomosynthesis group. © RSNA, 2013.

  6. Mammography screening services: market segments and messages.

    Science.gov (United States)

    Scammon, D L; Smith, J A; Beard, T

    1991-01-01

    Mammography has become a vital tool for the early detection of breast cancer. Although many organizations and health care facilities are working to educate and motivate women to take advantage of the life saving opportunity that is offered through screening mammography, only twenty percent of women who should be screened actually have the procedure performed. In order to reach women who have not been screened, it is important to learn which factors most strongly motivate those women who do choose to have a mammogram. Depth interviews with 18 women attending a mobile mammography unit were conducted to explore the decision making process of women obtaining mammography screening services and to develop a profile of prevalent emotions, attitudes, and feelings associated with receiving breast cancer screening services. Analysis of the interview transcripts revealed several important themes to which health care professionals can direct marketing and health promotion strategies.

  7. Comparison of low contrast detectability of computed tomography and screen/film mammography systems

    International Nuclear Information System (INIS)

    Noriah Jamal; Kwan Hoong Ng; McLean, D.

    2006-01-01

    The objective of this study was to compare low contrast detectability of computed radiography (CR) and screen/film (SF) mammography systems. The Nijimegen contrast detail test object (CDMAM type 3.4) was imaged at 28 kV, in automatic exposure control mode separately. Six medical imaging physicists read each CDMAM phantom image. Contrast detail curves were plotted to compare low contrast detectability of CR (soft copy and hard copy) and SF mammography systems. Effect of varying exposure parameters, namely kV, object position inside the breast phantom, and entrance surface exposure (ESE) on the contrast detail curve were also investigated using soft copy CR. The significant of the difference of contrast between CR and SF, and for each exposure parameter was tested using non-parametric Kruskal-Wallis test. We found that the low contrast detectability of CR (soft copy and hard copy) system is not significantly different to that of SF system (p>0.05, Kruskal-Wallis test). For CR soft copy, no significant relationship (p>0.05, Kruskal-Wallis test) was seen for variation of kV, object position inside the breast phantom and ESE. This indicates that CR is comparable with SF for useful detection and visualization of low contrast objects such as small low contrast areas corresponding to breast pathology

  8. Budget Impact Analysis of Switching to Digital Mammography in a Population-Based Breast Cancer Screening Program: A Discrete Event Simulation Model

    Science.gov (United States)

    Comas, Mercè; Arrospide, Arantzazu; Mar, Javier; Sala, Maria; Vilaprinyó, Ester; Hernández, Cristina; Cots, Francesc; Martínez, Juan; Castells, Xavier

    2014-01-01

    Objective To assess the budgetary impact of switching from screen-film mammography to full-field digital mammography in a population-based breast cancer screening program. Methods A discrete-event simulation model was built to reproduce the breast cancer screening process (biennial mammographic screening of women aged 50 to 69 years) combined with the natural history of breast cancer. The simulation started with 100,000 women and, during a 20-year simulation horizon, new women were dynamically entered according to the aging of the Spanish population. Data on screening were obtained from Spanish breast cancer screening programs. Data on the natural history of breast cancer were based on US data adapted to our population. A budget impact analysis comparing digital with screen-film screening mammography was performed in a sample of 2,000 simulation runs. A sensitivity analysis was performed for crucial screening-related parameters. Distinct scenarios for recall and detection rates were compared. Results Statistically significant savings were found for overall costs, treatment costs and the costs of additional tests in the long term. The overall cost saving was 1,115,857€ (95%CI from 932,147 to 1,299,567) in the 10th year and 2,866,124€ (95%CI from 2,492,610 to 3,239,638) in the 20th year, representing 4.5% and 8.1% of the overall cost associated with screen-film mammography. The sensitivity analysis showed net savings in the long term. Conclusions Switching to digital mammography in a population-based breast cancer screening program saves long-term budget expense, in addition to providing technical advantages. Our results were consistent across distinct scenarios representing the different results obtained in European breast cancer screening programs. PMID:24832200

  9. Mammographic microcalcifications: Detection with xerography, screen-film, and digitized film display

    International Nuclear Information System (INIS)

    Smathers, R.L.; Bush, E.; Drace, J.; Stevens, M.; Sommer, F.G.; Brown, B.W.; Karras, B.

    1986-01-01

    Pulverized bone specks and aluminum oxide specks were measured by hand into sizes ranging from 0.2 mm to 1.0 mm and then arranged in clusters. These clusters were superimposed on a human breast tissue phantom, and xeromammograms and screen-film mammograms of the clusters were made. The screen-film mammograms were digitized using a high-resolution laser scanner and then displayed on cathode ray tube (CRT) monitors. Six radiologists independently counted the microcalcifications on the xeromammograms, the screen-film mammograms, and the digitized film mammograms. The xeromammograms were examined with a magnifying glass; the screen-film images were examined with a magnifying glass and by hot light; and the digitized-film images were examined by electronic magnification and image processing. The bone speck size that corresponded to a mean 50% detectability level for each technique was as follows: xeromammography, 0.550 mm; digitized film, 0.573 mm; and screen-film, 0.661 mm. We postulate that electronic magnification and image processing with edge enhancement can improve the capability of screen-film mammography to enhance the detection of microcalcifications

  10. Pain during mammography: Implications for breast screening programmes

    International Nuclear Information System (INIS)

    Andrews, F.J.

    2001-01-01

    Pain experienced during mammography can deter women from attending for breast cancer screening. Review of the current literature on pain experienced during mammography reveals three main areas of interest: reports of the frequency of pain, identification of predictors of pain and strategies for responding to pain. Implications of this literature for breast screening programmes include the need for appropriate measurements of pain during mammography that are valid for screening populations, a further understanding of organizational factors involved in screening programmes that may be predictors of pain and for the development of valid strategies for responding to pain within breast screening programmes. Copyright (2001) Blackwell Science Pty Ltd

  11. Mammography screening: A major issue in medicine.

    Science.gov (United States)

    Autier, Philippe; Boniol, Mathieu

    2018-02-01

    Breast cancer mortality is declining in most high-income countries. The role of mammography screening in these declines is much debated. Screening impacts cancer mortality through decreasing the incidence of number of advanced cancers with poor prognosis, while therapies and patient management impact cancer mortality through decreasing the fatality of cancers. The effectiveness of cancer screening is the ability of a screening method to curb the incidence of advanced cancers in populations. Methods for evaluating cancer screening effectiveness are based on the monitoring of age-adjusted incidence rates of advanced cancers that should decrease after the introduction of screening. Likewise, cancer-specific mortality rates should decline more rapidly in areas with screening than in areas without or with lower levels of screening but where patient management is similar. These two criteria have provided evidence that screening for colorectal and cervical cancer contributes to decreasing the mortality associated with these two cancers. In contrast, screening for neuroblastoma in children was discontinued in the early 2000s because these two criteria were not met. In addition, overdiagnosis - i.e. the detection of non-progressing occult neuroblastoma that would not have been life-threatening during the subject's lifetime - is a major undesirable consequence of screening. Accumulating epidemiological data show that in populations where mammography screening has been widespread for a long time, there has been no or only a modest decline in the incidence of advanced cancers, including that of de novo metastatic (stage IV) cancers at diagnosis. Moreover, breast cancer mortality reductions are similar in areas with early introduction and high penetration of screening and in areas with late introduction and low penetration of screening. Overdiagnosis is commonplace, representing 20% or more of all breast cancers among women invited to screening and 30-50% of screen

  12. Barriers to Mammography among Inadequately Screened Women

    Science.gov (United States)

    Stoll, Carolyn R. T.; Roberts, Summer; Cheng, Meng-Ru; Crayton, Eloise V.; Jackson, Sherrill; Politi, Mary C.

    2015-01-01

    Mammography use has increased over the past 20 years, yet more than 30% of women remain inadequately screened. Structural barriers can deter individuals from screening, however, cognitive, emotional, and communication barriers may also prevent mammography use. This study sought to identify the impact of number and type of barriers on mammography…

  13. Digital mammography

    International Nuclear Information System (INIS)

    Bick, Ulrich; Diekmann, Felix

    2010-01-01

    This state-of-the-art reference book provides in-depth coverage of all aspects of digital mammography, including detector technology, image processing, computer-aided diagnosis, soft-copy reading, digital workflow, and PACS. Specific advantages and disadvantages of digital mammography in comparison to screen-film mammography are thoroughly discussed. By including authors from both North America and Europe, the book is able to outline variations in the use, acceptance, and quality assurance of digital mammography between the different countries and screening programs. Advanced imaging techniques and future developments such as contrast mammography and digital breast tomosynthesis are also covered in detail. All of the chapters are written by internationally recognized experts and contain numerous high-quality illustrations. This book will be of great interest both to clinicians who already use or are transitioning to digital mammography and to basic scientists working in the field. (orig.)

  14. Comparison of low-contrast detectability of computed radiography and screen/ film mammography systems

    International Nuclear Information System (INIS)

    Noriah Jamal; Kwan-Hoong Ng; McLean, D.; McLean, D.

    2008-01-01

    The objective of this study is to compare low-contrast detectability of computed radiography (CR) and screen/ film (SF) mammography systems. The Nijimegen contrast detail test object (CDMAM type 3.4) was imaged at 28 kV, in automatic exposure control mode separately. Six medical imaging physicists read each CDMAM phantom image. Contrast detail curves were plotted to compare low-contrast detectability of CR (soft copy and hard copy) and SF mammography systems. Effect of varying exposure parameters, namely kV, object position inside the breast phantom, and entrance surface exposure (ESE) on the contrast detail curve were also investigated using soft copy CR. The significance of the difference in contrast between CR and SF, and for each exposure parameter, was tested using non-parametric Kruskal-Wallis test. The low-contrast detectability of the CR (soft copy and hard copy) system was found to be not significantly different to that of the SF system (p> 0.05, Kruskal-Wallis test).For CR soft copy, no significant relationship (p>0.05, Kruskal-Wallis test) was seen for variation of kV, object position inside the breast phantom and ESE. This indicates that CR is comparable with SF for useful detection and visualization of low-contrast objects such as small low-contrast areas corresponding to breast pathology. (Author)

  15. Interobserver agreement and performance score comparison in quality control using a breast phantom: screen-film mammography vs computed radiography

    International Nuclear Information System (INIS)

    Shimamoto, Kazuhiro; Ikeda, Mitsuru; Satake, Hiroko; Ishigaki, Satoko; Sawaki, Akiko; Ishigaki, Takeo

    2002-01-01

    Our objective was to evaluate interobserver agreement and to compare the performance score in quality control of screen-film mammography and computed radiography (CR) using a breast phantom. Eleven radiologists interpreted a breast phantom image (CIRS model X) by four viewing methods: (a) original screen-film; (b) soft-copy reading of the digitized film image; (c) hard-copy reading of CR using an imaging plate; and (d) soft-copy reading of CR. For the soft-copy reading, a 17-in. CRT monitor (1024 x 1536 x 8 bits) was used. The phantom image was evaluated using a scoring system outlined in the instruction manual, and observers judged each object using a three-point rating scale: (a) clearly seen; (b) barely seen; and (c) not seen. For statistical analysis, the kappa statistic was employed. For ''mass'' depiction, interobserver agreement using CR was significantly lower than when using screen-film (p<0.05). There was no significant difference in the kappa value for detecting ''microcalcification''; however, the performance score of ''microcalcification'' on CR hard-copy was significantly lower than on the other three viewing methods (p<0.05). Viewing methods (film or CR, soft-copy or hard-copy) could affect how the phantom image is judged. Paying special attention to viewing conditions is recommended for quality control of CR mammograms. (orig.)

  16. Benefits, harms, and costs for breast cancer screening after US implementation of digital mammography.

    Science.gov (United States)

    Stout, Natasha K; Lee, Sandra J; Schechter, Clyde B; Kerlikowske, Karla; Alagoz, Oguzhan; Berry, Donald; Buist, Diana S M; Cevik, Mucahit; Chisholm, Gary; de Koning, Harry J; Huang, Hui; Hubbard, Rebecca A; Miglioretti, Diana L; Munsell, Mark F; Trentham-Dietz, Amy; van Ravesteyn, Nicolien T; Tosteson, Anna N A; Mandelblatt, Jeanne S

    2014-06-01

    Compared with film, digital mammography has superior sensitivity but lower specificity for women aged 40 to 49 years and women with dense breasts. Digital has replaced film in virtually all US facilities, but overall population health and cost from use of this technology are unclear. Using five independent models, we compared digital screening strategies starting at age 40 or 50 years applied annually, biennially, or based on density with biennial film screening from ages 50 to 74 years and with no screening. Common data elements included cancer incidence and test performance, both modified by breast density. Lifetime outcomes included mortality, quality-adjusted life-years, and screening and treatment costs. For every 1000 women screened biennially from age 50 to 74 years, switching to digital from film yielded a median within-model improvement of 2 life-years, 0.27 additional deaths averted, 220 additional false-positive results, and $0.35 million more in costs. For an individual woman, this translates to a health gain of 0.73 days. Extending biennial digital screening to women ages 40 to 49 years was cost-effective, although results were sensitive to quality-of-life decrements related to screening and false positives. Targeting annual screening by density yielded similar outcomes to targeting by age. Annual screening approaches could increase costs to $5.26 million per 1000 women, in part because of higher numbers of screens and false positives, and were not efficient or cost-effective. The transition to digital breast cancer screening in the United States increased total costs for small added health benefits. The value of digital mammography screening among women aged 40 to 49 years depends on women's preferences regarding false positives. © The Author 2014. Published by Oxford University Press. All rights reserved. For Permissions, please e-mail: journals.permissions@oup.com.

  17. Mammography screening among Arab American women in metropolitan Detroit.

    Science.gov (United States)

    Schwartz, Kendra; Fakhouri, Monty; Bartoces, Monina; Monsur, Joseph; Younis, Amani

    2008-12-01

    Mammography screening behavior has not been well studied among Middle Eastern immigrant women. We conducted a telephone survey of 365 Arab American women residing in metropolitan Detroit, home to one of the largest populations of Middle Eastern immigrants in the US, to determine prevalence of factors associated with mammography, and attitudes and beliefs regarding mammography screening. Of 365 participants, only five were born in the US. Mean age was 53.2 years (SD 10.8). Two hundred twelve (58.1%) reported having mammogram every 1-2 years; 70% ever had mammogram. Age 50-64 years, having health insurance, married status, being in the US over 10 years, and being Lebanese were associated with mammography every 1-2 years. After adjusting for demographic factors, perceived seriousness of disease, general health motivation, and having fewer barriers were associated with more frequent screening. Appropriate mammography screening is decreased in this group. Targeted outreach regarding screening is appropriate for this population; however, lack of insurance may prevent adequate follow-up.

  18. Image quality and radiation exposure in digital storage plate mammography with magnification technique

    International Nuclear Information System (INIS)

    Fiedler, E.; Aichinger, U.; Boehner, C.; Schulz-Wendtland, R.; Bautz, W.; Saebel, M.

    1999-01-01

    Purpose: Comparison of image quality between digital phosphor storage plate mammography in magnification technique and a conventional film screen system regarding the special aspect of radiation exposure. Materials and Methods: Radiograms of a RMI-mammography phantom were acquired using a conventional film screen system and two digital storage plate systems. Additionally, the radiograms of one digital system were postprocessed emphasizing contrast and included in the comparison. Results: The detectability of details in storage plate mammographies with magnification technique is almost equal to that of film screen mammographies. Thereby, lower radiation exposures were necessary using the digital systems. Conclusions: Based on these results, storage plate mammography in magnification technique is used in clinical routine at our institution. The correct parameters in image postprocessing are of elementary importance for detail detectability. Future studies must show, whether the lower radiation exposure in digital radiograms of the breast, revealing much higher background noise, will allow the same detail detectability as film screen mammographies. (orig.) [de

  19. Does health status influence intention regarding screening mammography?

    International Nuclear Information System (INIS)

    Park, Keeho; Park, Jong-Hyock; Park, Jae-Hyun; Kim, Hui-Jeong; Park, Bo-Yoon

    2010-01-01

    We analyzed information surveyed from a community-based sample of Korean women older than 40 years of age to understand the relationships between health status and screening behavior. In a cross-sectional population-based study, a two-stage, geographically stratified household-based sampling design was used for assembly of a probability sample of women aged 40-69 years living in Gunpo in Korea, resulting in a total sample size of 503 women. The primary outcome variable for this analysis was the respondent's intention to obtain a mammogram. Predictor variables included health status and other factors known to influence the use of cancer screening, such as age, education, income, marital status and the presence of co-morbid illnesses. Health status was assessed by using the EuroQol (EQ-5D). The median EQ visual analogue scale score was 75.0, ranging from 20 to 100. In bivariate analyses, the percentage of women reporting to have intention toward mammography use decreased with worsening health status. Women who had problems with mobility or anxiety/depression showed lower intention to undergo future screening mammography. Multivariate logistic regression confirmed that health status was significantly associated with intention toward mammography use. Anxiety or depression was an independent predictor of future screening mammography use. Health status is significantly associated with intention regarding screening mammography use. Physicians or other health professionals should be aware that health status is an important component for health promotion, and should pay more attention to clients' possible vulnerability in screening mammography use due to their poor health status. (author)

  20. Mechanistic modeling for mammography screening risks

    International Nuclear Information System (INIS)

    Bijwaard, Harmen

    2008-01-01

    Full text: Western populations show a very high incidence of breast cancer and in many countries mammography screening programs have been set up for the early detection of these cancers. Through these programs large numbers of women (in the Netherlands, 700.000 per year) are exposed to low but not insignificant X-ray doses. ICRP based risk estimates indicate that the number of breast cancer casualties due to mammography screening can be as high as 50 in the Netherlands per year. The number of lives saved is estimated to be much higher, but for an accurate calculation of the benefits of screening a better estimate of these risks is indispensable. Here it is attempted to better quantify the radiological risks of mammography screening through the application of a biologically based model for breast tumor induction by X-rays. The model is applied to data obtained from the National Institutes of Health in the U.S. These concern epidemiological data of female TB patients who received high X-ray breast doses in the period 1930-1950 through frequent fluoroscopy of their lungs. The mechanistic model that is used to describe the increased breast cancer incidence is based on an earlier study by Moolgavkar et al. (1980), in which the natural background incidence of breast cancer was modeled. The model allows for a more sophisticated extrapolation of risks to the low dose X-ray exposures that are common in mammography screening and to the higher ages that are usually involved. Furthermore, it allows for risk transfer to other (non-western) populations. The results have implications for decisions on the frequency of screening, the number of mammograms taken at each screening, minimum and maximum ages for screening and the transfer to digital equipment. (author)

  1. Impact of a CAD system in a screen-film mammography screening program: A prospective study

    International Nuclear Information System (INIS)

    Sanchez Gómez, S.; Torres Tabanera, M.; Vega Bolivar, A.; Sainz Miranda, M.; Baroja Mazo, A.; Ruiz Diaz, M.; Martinez Miravete, P.; Lag Asturiano, E.; Muñoz Cacho, P.; Delgado Macias, T.

    2011-01-01

    Objective: The purpose of our study was to perform a prospective assessment of the impact of a CAD system in a screen-film mammography screening program during a period of 3 years. Materials and methods: Our study was carried out on a population of 21,855 asymptomatic women (45–65 years). Mammograms were processed in a CAD system and independently interpreted by one of six radiologists. We analyzed the following parameters: sensitivity of radiologist's interpretation (without and with CAD), detection increase, recall rate and positive predictive value of biopsy, CAD's marks, radiologist's false negatives and comparative analysis of carcinomas detected and non-detected by CAD. Results: Detection rate was 4.3‰. CAD supposed an increase of 0.1‰ in detection rate and 1% in the total number of cases (p < 0.005). The impact on recall rate was not significant (0.4%) and PPV of percutaneous biopsy was unchanged by CAD (20.23%). CAD's marks were 2.7 per case and 0.7 per view. Radiologist's false negatives were 13 lesions which were initially considered as CAD's false positives. Conclusions: CAD supposed a significant increase in detection, without modifications in recall rates and PPV of biopsy. However, better results could have been achieved if radiologists had considered actionable those cases marked by CAD but initially misinterpreted.

  2. Screening for breast cancer with mammography

    International Nuclear Information System (INIS)

    Sickles, E.A.

    1991-01-01

    Mammography is generally accepted as a useful problem-solving clinical tool in characterizing known breast lesions, so that appropriate and timely treatment can be given. However, it remains grossly underutilized at what it does best: screening. The major strengths of mammography are (a) its ability to detect breast cancer at a smaller, potentially more curable stage than any other examination, and (b) its proved efficacy in reducing breast cancer mortality in asymptomatic women aged 40-74. If, as has recently been estimated, screening with mammography and physical examination can be expected to lower breast cancer deaths by 40%-50% among those actually examined (13), then the lives of almost 20,000 U.S. women might be saved each year if screening were to become very widely used. The challenges of the next decade are clear, to mount much more effective campaigns to educate physicians and lay women about the life-saving benefits of breast cancer screening, to devise increasingly effective and lower cost screening strategies, to further improve the current high quality of mammographic imaging despite its increasing proliferation, and to train large numbers of breast imaging specialists to guarantee that the growing case load of screening and problem-solving mammograms is interpreted with a very high level of skill

  3. At what age should screening mammography be recommended for Asian women?

    International Nuclear Information System (INIS)

    Tsuchida, Junko; Nagahashi, Masayuki; Rashid, Omar M; Takabe, Kazuaki; Wakai, Toshifumi

    2015-01-01

    Although regular screening mammography has been suggested to be associated with improvements in the relative survival of breast cancer in recent years, the appropriate age to start screening mammography remains controversial. In November 2009, the United States Preventive Service Task Force published updated guidelines for breast cancer, which no longer support routine screening mammography for women aged 40–49 years, but instead, defer the choice of screening in that age group to the patient and physician. The age to begin screening differs between guidelines, including those from the Task Force, the American Cancer Society and the World Health Organization. It remains unclear how this discrepancy impacts patient survival, especially among certain subpopulations. Although the biological characteristics of breast cancer and peak age of incidence differ among different ethnic populations, there have been few reports that evaluate the starting age for screening mammography based on ethnicity. Here, we discuss the benefits and harm of screening mammography in the fifth decade, and re-evaluate the starting age for screening mammography taking ethnicity into account, focusing on the Asian population. Breast cancer incidence peaked in the fifth decade in Asian women, which has been thought to be due to a combination of biological and environmental factors. Previous reports suggest that Asian women in their 40s may receive more benefit and less harm from screening mammography than the age-matched non-Asian US population. Therefore, starting screening mammography at age 40 may be beneficial for women of Asian ethnicity in well-resourced countries, such as Japanese women who reside in Japan

  4. Decision making and counseling around mammography screening for women aged 80 or older.

    Science.gov (United States)

    Schonberg, Mara A; Ramanan, Radhika A; McCarthy, Ellen P; Marcantonio, Edward R

    2006-09-01

    Despite uncertain benefit, many women over age 80 (oldest-old) receive screening mammography. To explore decision-making and physician counseling of oldest-old women around mammography screening. Qualitative research using in-depth semi-structured interviews. Twenty-three women aged 80 or older who received care at a large academic primary care practice (13 had undergone mammography screening in the past 2 years) and 16 physicians at the same center. We asked patients and physicians to describe factors influencing mammography screening decisions of oldest-old women. We asked physicians to describe their counseling about screening to the oldest-old. Patients and/or physicians identified the importance of physician influence, patient preferences, system factors, and social influences on screening decisions. Although physicians felt that patient's health affected screening decisions, few patients felt that health mattered. Three types of elderly patients were identified: (1) women enthusiastic about screening mammography; (2) women opposed to screening mammography; and (3) women without a preference who followed their physician's recommendation. However, physician counseling about mammography screening to elderly women varies; some individualize discussions; others encourage screening; few discourage screening. Physicians report that discussions about stopping screening can be uncomfortable and time consuming. Physicians suggest that more data could facilitate these discussions. Some oldest-old women have strong opinions about screening mammography while others are influenced by physicians. Discussions about stopping screening are challenging for physicians. More data about the benefits and risks of mammography screening for women aged 80 or older could inform patients and improve provider counseling to lead to more rational use of mammography.

  5. Breast cancer screening: the underuse of mammography

    International Nuclear Information System (INIS)

    Fox, S.; Baum, J.K.; Klos, D.S.; Tsou, C.V.

    1985-01-01

    The early detection of breast cancer is promoted by the American Cancer Society (ACS) and the American College of Radiology (ACR) by encouraging the regular use of three types of screening: breast self-examination (BSE), the clinical breast examination, and mammography. In August 1983, the ACS publicized seven recommendations pertaining to screening, including a revised statement about the routine use of mammography for women between the ages of 40 and 49 years. In response to the ACS statement, the present study assessed compliance with the updated recommendations for all three types of screening. The results show reasonable rates of compliance for the BSE (53%-69%) and clinical examination (70%-78%). In contrast, only 19% of the women between the ages of 35 and 49 and 25% of the women older than 50 reported complying with the recommendation to undergo one baseline screening mammogram. Some implications for health education by physicians and the professional education of physicians in the use of mammography are discussed

  6. Study of mammography in mass screening for breast cancer

    International Nuclear Information System (INIS)

    Kitada, Masahiro; Sakai, Hiroko; Kubo, Yoshihiko; Samejima, Natsuki; Kurowarabi, Kunio; Iwabuchi, Shuji.

    1995-01-01

    In order to examine the rate of correct diagnosis by mammography at initial mass screening for breast cancer, we carried out a retrospective study of mammography findings in 267 cases of breast cancer detected at Asahikawa Cancer Screening Center. The screening was performed by physical examination, and in cases where disease was suspected, mammography, ultrasonography, and needle biopsy were done. Mammographically, 172 cases (64.4%) were cancer-positive, 58 cases (21.7%) were suspicious for cancer, and 37 cases (13.9%) were cancer-negative. Patients below 50 years of age and those with tumors of small diameter (<20 mm) showed a significantly lower rate of cancer positivity than patients aged 50 years or more and those with tumors 20 mm or more in diameter. Mammographic abnormalities were not specific, since these changes were also found in normal subjects and patients with benign diseases. Therefore, we concluded that mammography without physical examination at initial mass screening has a high risk of missing breast cancer. Mass screening for breast cancer should be performed by physical examination involving inspection and palpation at the first instance. If any suspicious findings are obtained, mammography, ultrasonography, and needle biopsy should be done. (author)

  7. Factors influencing elderly women's mammography screening decisions: implications for counseling.

    Science.gov (United States)

    Schonberg, Mara A; McCarthy, Ellen P; York, Meghan; Davis, Roger B; Marcantonio, Edward R

    2007-11-16

    Although guidelines recommend that clinicians consider life expectancy before screening older women for breast cancer, many older women with limited life expectancies are screened. We aimed to identify factors important to mammography screening decisions among women aged 80 and older compared to women aged 65-79. Telephone surveys of 107 women aged 80+ and 93 women aged 65-79 randomly selected from one academic primary care practice who were able to communicate in English (60% response rate). The survey addressed the following factors in regards to older women's mammography screening decisions: perceived importance of a history of breast disease, family history of breast cancer, doctor's recommendations, habit, reassurance, previous experience, mailed reminder cards, family/friend's recommendations or experience with breast cancer, age, health, and media. The survey also assessed older women's preferred role in decision making around mammography screening. Of the 200 women, 65.5% were non-Hispanic white and 82.8% were in good to excellent health. Most (81.3%) had undergone mammography in the past 2 years. Regardless of age, older women ranked doctor's recommendations as the most important factor influencing their decision to get screened. Habit and reassurance were the next two highly ranked factors influencing older women to get screened. Among women who did not get screened, women aged 80 and older ranked age and doctor's counseling as the most influential factors and women aged 65-79 ranked a previous negative experience with mammography as the most important factor. There were no significant differences in preferred role in decision-making around mammography screening by age, however, most women in both age groups preferred to make the final decision on their own (46.6% of women aged 80+ and 50.5% of women aged 65-79). While a doctor's recommendation is the most important factor influencing elderly women's mammography screening decisions, habit and reassurance

  8. At what age should screening mammography be recommended for Asian women?

    Science.gov (United States)

    Tsuchida, Junko; Nagahashi, Masayuki; Rashid, Omar M; Takabe, Kazuaki; Wakai, Toshifumi

    2015-07-01

    Although regular screening mammography has been suggested to be associated with improvements in the relative survival of breast cancer in recent years, the appropriate age to start screening mammography remains controversial. In November 2009, the United States Preventive Service Task Force published updated guidelines for breast cancer, which no longer support routine screening mammography for women aged 40-49 years, but instead, defer the choice of screening in that age group to the patient and physician. The age to begin screening differs between guidelines, including those from the Task Force, the American Cancer Society and the World Health Organization. It remains unclear how this discrepancy impacts patient survival, especially among certain subpopulations. Although the biological characteristics of breast cancer and peak age of incidence differ among different ethnic populations, there have been few reports that evaluate the starting age for screening mammography based on ethnicity. Here, we discuss the benefits and harm of screening mammography in the fifth decade, and re-evaluate the starting age for screening mammography taking ethnicity into account, focusing on the Asian population. Breast cancer incidence peaked in the fifth decade in Asian women, which has been thought to be due to a combination of biological and environmental factors. Previous reports suggest that Asian women in their 40s may receive more benefit and less harm from screening mammography than the age-matched non-Asian US population. Therefore, starting screening mammography at age 40 may be beneficial for women of Asian ethnicity in well-resourced countries, such as Japanese women who reside in Japan. © 2015 The Authors. Cancer Medicine published by John Wiley & Sons Ltd.

  9. A comparison of digital mammography detectors and emerging technology

    International Nuclear Information System (INIS)

    Diffey, J.L.

    2015-01-01

    The overall diagnostic accuracy of digital mammography in the context of screening has been shown to be similar or slightly better than screen-film mammography. However, digital mammography encompasses both Computed Radiography (CR) and integrated Digital Radiography (DR) and there is increasing evidence to suggest that differences in detector technology are associated with variations in cancer detection rate, dose and image quality. These differences are examined in detail. Although digital mammography offers many advantages compared to screen-film, there are still some limitations with its use as a screening tool and reduced cancer detection in dense breasts remains an issue. Digital mammography detectors have paved the way for emerging technologies which may offer improvements. Taking the definition of mammography to only include X-ray imaging of the breast, this article focuses on tomosynthesis, contrast-enhanced digital mammography, stereoscopic mammography and dedicated breast computed tomography. Advanced software applications such as Computed Aided Detection (CAD) and quantitative breast density assessment are also presented. The benefits and limitations of each technique are discussed. - Highlights: • Digital detector technology affects cancer detection rate, dose and image quality. • Digital detectors have facilitated new technologies such as tomosynthesis. • 3-D techniques reduce superimposition and increase cancer detection in dense breasts. • Contrast-enhanced mammography demonstrates improved sensitivity and specificity.

  10. Breast cancer screening using tomosynthesis in combination with digital mammography.

    Science.gov (United States)

    Friedewald, Sarah M; Rafferty, Elizabeth A; Rose, Stephen L; Durand, Melissa A; Plecha, Donna M; Greenberg, Julianne S; Hayes, Mary K; Copit, Debra S; Carlson, Kara L; Cink, Thomas M; Barke, Lora D; Greer, Linda N; Miller, Dave P; Conant, Emily F

    2014-06-25

    Mammography plays a key role in early breast cancer detection. Single-institution studies have shown that adding tomosynthesis to mammography increases cancer detection and reduces false-positive results. To determine if mammography combined with tomosynthesis is associated with better performance of breast screening programs in the United States. Retrospective analysis of screening performance metrics from 13 academic and nonacademic breast centers using mixed models adjusting for site as a random effect. Period 1: digital mammography screening examinations 1 year before tomosynthesis implementation (start dates ranged from March 2010 to October 2011 through the date of tomosynthesis implementation); period 2: digital mammography plus tomosynthesis examinations from initiation of tomosynthesis screening (March 2011 to October 2012) through December 31, 2012. Recall rate for additional imaging, cancer detection rate, and positive predictive values for recall and for biopsy. A total of 454,850 examinations (n=281,187 digital mammography; n=173,663 digital mammography + tomosynthesis) were evaluated. With digital mammography, 29,726 patients were recalled and 5056 biopsies resulted in cancer diagnosis in 1207 patients (n=815 invasive; n=392 in situ). With digital mammography + tomosynthesis, 15,541 patients were recalled and 3285 biopsies resulted in cancer diagnosis in 950 patients (n=707 invasive; n=243 in situ). Model-adjusted rates per 1000 screens were as follows: for recall rate, 107 (95% CI, 89-124) with digital mammography vs 91 (95% CI, 73-108) with digital mammography + tomosynthesis; difference, -16 (95% CI, -18 to -14; P tomosynthesis; difference, 1.3 (95% CI, 0.4-2.1; P = .004); for cancer detection, 4.2 (95% CI, 3.8-4.7) with digital mammography vs 5.4 (95% CI, 4.9-6.0) with digital mammography + tomosynthesis; difference, 1.2 (95% CI, 0.8-1.6; P tomosynthesis; difference, 1.2 (95% CI, 0.8-1.6; P tomosynthesis was associated with an increase

  11. Mammography at reduced doses: present performance and future possibilities

    International Nuclear Information System (INIS)

    Muntz, E.P.; Wilkinson, E.; George, F.W.

    1980-01-01

    Reduced dose mammography is assessed with the aid of very recent work. It is concluded that there are technical and clinical reasons for believing that the reduced dose systems and their interpreters should perform more effectively than their predecessors. Review of known technologic achievements suggests a possible 6 to 7 reduction factor from present screen-film mammography dose levels without sacficifing image quality. Reasonable estimates of representative doses presently achieved by both xeroradiography and screen-film systems are given. The screen-film value is about 3 times higher than some previous

  12. Effect on sensitivity and specificity of mammography screening with or without comparison of old mammograms

    International Nuclear Information System (INIS)

    Thurfjell, M.G.; Vitak, B.; Azavedo, E.; Svane, G.; Thurfjell, E.

    2000-01-01

    In order to evaluate the effect of old mammograms on the specificity and sensitivity of radiologists in mammography screening, one hundred and fifty sets of screening mammograms were examined by 3 experienced screeners twice: once without and once in comparison with older mammograms. The films came from a population-based screening done during the first half of 1994 and comprised all 35 cancers detected during screening in 1994, 12/24 interval cancers, 14/34 cancers detected in the following screening and 89 normal mammograms. Without old mammograms, the screeners detected an average of 40.3 cancers (range 37-42), with a specificity of 87% (85-88%). With old mammograms, the screeners detected 37.7 cancers (range 34-42) with a specificity of 96% (94-99%). The change in detection rate was not significant. However, the increase in specificity was significant for each screener. Mammography screening with old mammograms available for comparison decreased the false-positive recall rate. The effect on sensitivity, however, was unclear

  13. Evidence on Synthesized Two-dimensional Mammography Versus Digital Mammography When Using Tomosynthesis (Three-dimensional Mammography) for Population Breast Cancer Screening.

    Science.gov (United States)

    Houssami, Nehmat

    2017-09-28

    One limitation of using digital breast tomosynthesis (3-dimensional [3D] mammography) technology with conventional (2-dimensional [2D]) mammography for breast cancer (BC) screening is the increased radiation dose from dual acquisitions. To resolve this problem, synthesized 2D (s2D) reconstruction images similar to 2D mammography were developed using tomosynthesis acquisitions. The present review summarizes the evidence for s2D versus digital mammography (2D) when using tomosynthesis (3D) for BC screening to address whether using s2D instead of 2D (alongside 3D) will yield similar detection measures. Comparative population screening studies have provided consistent evidence that cancer detection rates do not differ between integrated 2D/3D (range, 5.45-8.5/1000 screens) and s2D/3D (range, 5.03-8.8/1000 screens). Also, although the recall measures were relatively heterogeneous across included studies, little difference was found between the 2 modalities. The mean glandular dose for s2D/3D was 55% to 58% of that for 2D/3D. In the context of BC screening, s2D/3D involves substantially less radiation than 2D/3D and provides similar detection measures. Thus, consideration of transitioning to tomosynthesis screening should aim to use s2D/3D to minimize harm. Copyright © 2017 Elsevier Inc. All rights reserved.

  14. Hidden costs of low-cost screening mammography

    International Nuclear Information System (INIS)

    Cyrlak, D.

    1987-01-01

    Twenty-two hundred women in Orange County, California, took part in a low-cost mammography screening project sponsored by the American Cancer Society and the KCBS-TV. Patients were followed up by telephone and questioned about actual costs incurred as a result of screening mammography, including costs of repeated and follow-up mammograms, US examinations and surgical consultations. The total number of biopsies, cancers found, and the costs involved were investigated. The authors' results suggest that particularly in centers with a high positive call rate, the cost of screening mammograms accounts for only a small proportion of the medical costs

  15. Breast Cancer Screening, Mammography, and Other Modalities.

    Science.gov (United States)

    Fiorica, James V

    2016-12-01

    This article is an overview of the modalities available for breast cancer screening. The modalities discussed include digital mammography, digital breast tomosynthesis, breast ultrasonography, magnetic resonance imaging, and clinical breast examination. There is a review of pertinent randomized controlled trials, studies and meta-analyses which contributed to the evolution of screening guidelines. Ultimately, 5 major medical organizations formulated the current screening guidelines in the United States. The lack of consensus in these guidelines represents an ongoing controversy about the optimal timing and method for breast cancer screening in women. For mammography screening, the Breast Imaging Reporting and Data System lexicon is explained which corresponds with recommended clinical management. The presentation and discussion of the data in this article are designed to help the clinician individualize breast cancer screening for each patient.

  16. Digital mammography in breast cancer screening: Evaluation and innovation

    NARCIS (Netherlands)

    Bluekens, A.M.J.

    2015-01-01

    With all other imaging modalities in radiology being digitised and conventional mammography being ready to phase out the transition to digital mammography was inevitable. This thesis describes the performance of digital screening mammography and the consequences of implementation in a

  17. Data on the cost-benefit analysis of mammography

    International Nuclear Information System (INIS)

    Zarand, P.; Pentek, Z.

    1982-01-01

    The radiation exposure and the cost per examination are compared in the case of three methods: non-screen film mammography, 10-dose mammography and xeromammography. 10-dose mammography results in the lowest radiation exposure whereas xeromammography has the lowest cost. (L.E.)

  18. Factors influencing elderly women's mammography screening decisions: implications for counseling

    Directory of Open Access Journals (Sweden)

    Davis Roger B

    2007-11-01

    Full Text Available Abstract Background Although guidelines recommend that clinicians consider life expectancy before screening older women for breast cancer, many older women with limited life expectancies are screened. We aimed to identify factors important to mammography screening decisions among women aged 80 and older compared to women aged 65–79. Methods Telephone surveys of 107 women aged 80+ and 93 women aged 65–79 randomly selected from one academic primary care practice who were able to communicate in English (60% response rate. The survey addressed the following factors in regards to older women's mammography screening decisions: perceived importance of a history of breast disease, family history of breast cancer, doctor's recommendations, habit, reassurance, previous experience, mailed reminder cards, family/friend's recommendations or experience with breast cancer, age, health, and media. The survey also assessed older women's preferred role in decision making around mammography screening. Results Of the 200 women, 65.5% were non-Hispanic white and 82.8% were in good to excellent health. Most (81.3% had undergone mammography in the past 2 years. Regardless of age, older women ranked doctor's recommendations as the most important factor influencing their decision to get screened. Habit and reassurance were the next two highly ranked factors influencing older women to get screened. Among women who did not get screened, women aged 80 and older ranked age and doctor's counseling as the most influential factors and women aged 65–79 ranked a previous negative experience with mammography as the most important factor. There were no significant differences in preferred role in decision-making around mammography screening by age, however, most women in both age groups preferred to make the final decision on their own (46.6% of women aged 80+ and 50.5% of women aged 65–79. Conclusion While a doctor's recommendation is the most important factor influencing

  19. Comparison of digital mammography alone and digital mammography plus tomosynthesis in a population-based screening program.

    Science.gov (United States)

    Skaane, Per; Bandos, Andriy I; Gullien, Randi; Eben, Ellen B; Ekseth, Ulrika; Haakenaasen, Unni; Izadi, Mina; Jebsen, Ingvild N; Jahr, Gunnar; Krager, Mona; Niklason, Loren T; Hofvind, Solveig; Gur, David

    2013-04-01

    To assess cancer detection rates, false-positive rates before arbitration, positive predictive values for women recalled after arbitration, and the type of cancers detected with use of digital mammography alone and combined with tomosynthesis in a large prospective screening trial. A prospective, reader- and modality-balanced screening study of participants undergoing combined mammography plus tomosynthesis, the results of which were read independently by four different radiologists, is under way. The study was approved by a regional ethics committee, and all participants provided written informed consent. The authors performed a preplanned interim analysis of results from 12,631 examinations interpreted by using mammography alone and mammography plus tomosynthesis from November 22, 2010, to December 31, 2011. Analyses were based on marginal log-linear models for binary data, accounting for correlated interpretations and adjusting for reader-specific performance levels by using a two-sided significance level of .0294. Detection rates, including those for invasive and in situ cancers, were 6.1 per 1000 examinations for mammography alone and 8.0 per 1000 examinations for mammography plus tomosynthesis (27% increase, adjusted for reader; P = .001). False-positive rates before arbitration were 61.1 per 1000 examinations with mammography alone and 53.1 per 1000 examinations with mammography plus tomosynthesis (15% decrease, adjusted for reader; P tomosynthesis; P = .72). Twenty-five additional invasive cancers were detected with mammography plus tomosynthesis (40% increase, adjusted for reader; P tomosynthesis (P tomosynthesis in a screening environment resulted in a significantly higher cancer detection rate and enabled the detection of more invasive cancers. Clinical trial registration no. NCT01248546. RSNA, 2013

  20. Computer-aided detection of masses in full-field digital mammography using screen-film mammograms for training

    International Nuclear Information System (INIS)

    Kallenberg, Michiel; Karssemeijer, Nico

    2008-01-01

    It would be of great value when available databases of screen-film mammography (SFM) images can be used to train full-field digital mammography (FFDM) computer-aided detection (CAD) systems, as compilation of new databases is costly. In this paper, we investigate this possibility. Firstly, we develop a method that converts an FFDM image into an SFM-like representation. In this conversion method, we establish a relation between exposure and optical density by simulation of an automatic exposure control unit. Secondly, we investigate the effects of using the SFM images as training samples compared to training with FFDM images. Our FFDM database consisted of 266 cases, of which 102 were biopsy-proven malignant masses and 164 normals. The images were acquired with systems of two different manufacturers. We found that, when we trained our FFDM CAD system with a small number of images, training with FFDM images, using a five-fold crossvalidation procedure, outperformed training with SFM images. However, when the full SFM database, consisting of 348 abnormal cases (including 204 priors) and 810 normal cases, was used for training, SFM training outperformed FFDMA training. These results show that an existing CAD system for detection of masses in SFM can be used for FFDM images without retraining.

  1. Body weight and sensitivity of screening mammography

    DEFF Research Database (Denmark)

    Njor, Sisse H.; von Euler-Chelpin, My; Tjønneland, Anne

    2016-01-01

    benefit more from screening than other women. Methods: We combined data from the Danish Diet, Cancer and Health study and the organised population-based screening mammography programme in Copenhagen, Denmark. Women were categorised according to body mass index (BMI) (...Aim: Obese women tend to participate less in breast cancer screening than normal weight women. However, obese women have fattier breast than normal weight women, and screening mammography works better in fatty than in dense breasts. One might, therefore, hypothesise that obese women would actually......, and 35+). We measured recall rate, sensitivity and specificity for subsequent screens with a 2-year follow-up period. Results: The study included 6787 women. The recall rate varied from 1.4% for women with BMI women with BMI 35+, test for trend p = 0.86. Sensitivity varied from 42% (95...

  2. Experience with digital mammography

    Directory of Open Access Journals (Sweden)

    G. P. Korzhenkova

    2011-01-01

    Full Text Available The use of digital techniques in mammography has become a last step for completing the process of digitization in diagnostic imaging. It is assumed that such a spatial decision will be required for digital mammography, as well as for high-resolution intensifying screen-film systems used in conventional mammography and that the digital techniques will be limited by the digitizer pixel size on detecting minor structures, such as microcalcifications. The introduction of digital technologies in mammography involves a tight control over an image and assures its high quality.

  3. Slit aperture technique for mammography

    International Nuclear Information System (INIS)

    Friedrich, M.

    1984-01-01

    Following a discussion of various principles used in the elimination of scatter, the prototype of a simple slit aperture mammography apparatus is described (modified Mammomat, Siemens). The main advantage of this technique compared with grid mammography is a halving of the radiation dose for identical image quality, using an identical film system. The technical requirements (heavy duty tube, new generator) are, however, considerable. If the film-screen systems currently in use are to remain the common systems for the future, then the development of a multi-lamellar slit diaphragm technique carries much promise for mammography. (orig.) [de

  4. [Commentary on the planned restructuring of mammography screening in Austria].

    Science.gov (United States)

    Vutuc, Christian; Haidinger, Gerald

    2011-08-01

    With regards to the planned reorganisation of screening mammography in Austria - from an opportunistic to an organised system - the problems related with such a change are depicted from an epidemiological point of view. We were able to demonstrate earlier that opportunistic screening mammography matches the results of controlled screening mammography in Finland and Sweden. Switching to a controlled system in Austria would - besides the need for a change in legislation - lead to enormous expenditures in terms of resources needed and moreover, it could be not evaluated for years.

  5. Implications of Overdiagnosis: Impact on Screening Mammography Practices

    Science.gov (United States)

    Morris, Elizabeth; Feig, Stephen A.; Drexler, Madeline

    2015-01-01

    Abstract This review article explores the issue of overdiagnosis in screening mammography. Overdiagnosis is the screen detection of a breast cancer, histologically confirmed, that might not otherwise become clinically apparent during the lifetime of the patient. While screening mammography is an imperfect tool, it remains the best tool we have to diagnose breast cancer early, before a patient is symptomatic and at a time when chances of survival and options for treatment are most favorable. In 2015, an estimated 231,840 new cases of breast cancer (excluding ductal carcinoma in situ) will be diagnosed in the United States, and some 40,290 women will die. Despite these data, screening mammography for women ages 40–69 has contributed to a substantial reduction in breast cancer mortality, and organized screening programs have led to a shift from late-stage diagnosis to early-stage detection. Current estimates of overdiagnosis in screening mammography vary widely, from 0% to upwards of 30% of diagnosed cancers. This range reflects the fact that measuring overdiagnosis is not a straightforward calculation, but usually one based on different sets of assumptions and often biased by methodological flaws. The recent development of tomosynthesis, which creates high-resolution, three-dimensional images, has increased breast cancer detection while reducing false recalls. Because the greatest harm of overdiagnosis is overtreatment, the key goal should not be less diagnosis but better treatment decision tools. (Population Health Management 2015;18:S3–S11) PMID:26414384

  6. Mammography screening in Denmark

    DEFF Research Database (Denmark)

    Vejborg, Ilse; Mikkelsen, Ellen Margrethe; Garne, Jens Peter

    2011-01-01

    Mammography screening is offered healthy women, and a high standard on professional and organizational level is mandatory not only in the screening programme but even in the diagnostic work-up and treatment. The main goal is to achieve a substantial reduction in disease specific mortality......, but it is not possible to evaluate the effect on mortality until several years later, and continuously monitoring of the quality of all aspects of a screening programme is necessary. Based on other European guidelines, 11 quality indicators have been defined, and guidelines concerning organizational requirements...... for a Danish screening programme as well as recommendations for the radiographic and radiological work have been drawn up....

  7. Barriers to Mammography Screening: How to Overcome Them

    Directory of Open Access Journals (Sweden)

    Yasmin Hassoun

    2015-10-01

    Full Text Available Background: Screening mammography is an established intervention that leads to early breast cancer detection and reduced mortality. The Lebanese Ministry of Health has initiated yearly awareness campaigns and provided free mammography in multiple centers around the country. Methods: The study took place in two major areas of Lebanon - Beirut and South Lebanon. This cross-sectional survey aimed to assess knowledge about breast cancer screening and screening behaviors in the Lebanese population. The primary outcome of the study was to assess the reasons that prevented women from performing screening mammography based on our categories of questions: lack of knowledge about breast cancer, lack of access to screening facilities, failure of primary care physician to encourage screening behavior, and other reasons. Results: The major barriers to seek screening that had statistically significant P-values, in order of prevalence, included: lack of knowledge about breast cancer, followed by social reasons and lack of access. Conclusion: Given the prevalence of breast cancer in our population, it is important to understand the pitfalls that we experience in promoting awareness. Our study is the first study to reach out to the community to assess perceived barriers against screening and provide solutions for such barriers.

  8. Estimating the relative utility of screening mammography.

    Science.gov (United States)

    Abbey, Craig K; Eckstein, Miguel P; Boone, John M

    2013-05-01

    The concept of diagnostic utility is a fundamental component of signal detection theory, going back to some of its earliest works. Attaching utility values to the various possible outcomes of a diagnostic test should, in principle, lead to meaningful approaches to evaluating and comparing such systems. However, in many areas of medical imaging, utility is not used because it is presumed to be unknown. In this work, we estimate relative utility (the utility benefit of a detection relative to that of a correct rejection) for screening mammography using its known relation to the slope of a receiver operating characteristic (ROC) curve at the optimal operating point. The approach assumes that the clinical operating point is optimal for the goal of maximizing expected utility and therefore the slope at this point implies a value of relative utility for the diagnostic task, for known disease prevalence. We examine utility estimation in the context of screening mammography using the Digital Mammographic Imaging Screening Trials (DMIST) data. We show how various conditions can influence the estimated relative utility, including characteristics of the rating scale, verification time, probability model, and scope of the ROC curve fit. Relative utility estimates range from 66 to 227. We argue for one particular set of conditions that results in a relative utility estimate of 162 (±14%). This is broadly consistent with values in screening mammography determined previously by other means. At the disease prevalence found in the DMIST study (0.59% at 365-day verification), optimal ROC slopes are near unity, suggesting that utility-based assessments of screening mammography will be similar to those found using Youden's index.

  9. Effect of adding screening ultrasonography to screening mammography on patient recall and cancer detection rates: A retrospective study in Japan

    International Nuclear Information System (INIS)

    Tohno, Eriko; Umemoto, Takeshi; Sasaki, Kyoko; Morishima, Isamu; Ueno, Ei

    2013-01-01

    Purpose: To determine whether adding screening ultrasonography to screening mammography can reduce patient recall rates and increase cancer detection rates. Materials and methods: We analyzed the results of mammography and ultrasonography breast screenings performed at the Total Health Evaluation Center Tsukuba, Japan, between April 2011 and March 2012. We also reviewed the modalities and results of diagnostic examinations from women with mammographic abnormalities who visited the Tsukuba Medical Center Hospital for further testing. Results: Of 11,753 women screened, cancer was diagnosed in 10 (0.22%) of the 4529 participants who underwent mammography alone, 23 (0.37%) of the 6250 participants who underwent ultrasonography alone, and 5 (0.51%) of the 974 participants who underwent mammography and ultrasonography. The recall rate due to mammographic abnormalities was 4.9% for women screened only with mammography and 2.6% for those screened with both modalities. The cancer detection rate was 0.22% for women screened only with mammography (positive predictive value, 4.5%) and 0.31% for those screened with both modalities (positive predictive value, 12.0%). Of the 211 lesions presenting as mammographic abnormalities investigated further, diagnostic ultrasonography found no abnormalities in 63 (29.9%) and benign findings in 69 (33.7%). The rest 36.4% needed mammography, cytological or histological examinations or follow-up in addition to diagnostic ultrasonography. Conclusions: It is possible to reduce the recall rate in screening mammography by combining mammography and ultrasonography for breast screening

  10. Mammography screening credit card and compliance.

    Science.gov (United States)

    Schapira, D V; Kumar, N B; Clark, R A; Yag, C

    1992-07-15

    Screening for breast cancer using mammography has been shown to be effective in reducing mortality from breast cancer. The authors attempted to determine if use of a wallet-size plastic screening "credit" card would increase participants' compliance for subsequent mammograms when compared with traditional methods of increasing compliance. Two hundred and twenty consecutive women, ages 40-70 years, undergoing their first screening mammography were recruited and assigned randomly to four groups receiving (1) a reminder plastic credit card (2) reminder credit card with written reminder; (3) appointment card; and (4) verbal recommendation. Return rates of the four groups were determined after 15 months. The return rate for subsequent mammograms was significantly higher for participants (72.4%) using the credit card than for participants (39.8%) exposed to traditional encouragement/reminders (P less than 0.0001). The credit card was designed to show the participant's screening anniversary, and the durability of the card may have been a factor in increasing the return rate. The use of reminder credit cards may increase compliance for periodic screening examinations for other cancers and other chronic diseases.

  11. Physical and Clinical Comparison between a Screen-Film System and a Dual-Side Reading Mammography-Dedicated Computed Radiography System

    International Nuclear Information System (INIS)

    Rivetti, S.; Canossi, B.; Battista, R.; Vetruccio, E.; Torricelli, P.; Lanconelli, N.; Danielli, C.; Borasi, G.

    2009-01-01

    Background: Digital mammography systems, thanks to a physical performance better than conventional screen-film units, have the potential of reducing the dose to patients, without decreasing the diagnostic accuracy. Purpose: To achieve a physical and clinical comparison between two systems: a screen-film plate and a dual-side computed radiography system (CRM; FUJIFILM FCR 5000 MA). Material and Methods: A unique feature of the FCR 5000 MA system is that it has a clear support medium, allowing light emitted during the scanning process to be detected on the 'back' of the storage phosphor plate, considerably improving the system's efficiency. The system's physical performance was tested by means of a quantitative analysis, with calculation of the modulation transfer function, detective quantum efficiency, and contrast-detail analysis; subsequently, the results were compared with those achieved using a screen-film system (SFM; Eastmann Kodak MinR-MinR 2000). A receiver operating characteristic (ROC) analysis was then performed on 120 paired clinical images obtained in a craniocaudal projection with the conventional SFM system under standard exposure conditions and also with the CRM system working with a dose reduced by 35% (average breast thickness: 4.3 cm; mean glandular dose: 1.45 mGy). CRM clinical images were interpreted both in hard copy and in soft copy. Results: The ROC analysis revealed that the performances of the two systems (SFM and CRM with reduced dose) were similar (P>0.05): the diagnostic accuracy of the two systems, when valued in terms of the area underneath the ROC curve, was found to be 0.74 for the SFM, 0.78 for the CRM (hard copy), and 0.79 for the CRM (soft copy). Conclusion: The outcome obtained from our experiments shows that the use of the dual-side CRM system is a very good alternative to the screen-film system

  12. Digital mammography: what do we and what don't we know?

    International Nuclear Information System (INIS)

    Bick, Ulrich; Diekmann, Felix

    2007-01-01

    High-quality full-field digital mammography has been available now for several years and is increasingly used for both diagnostic and screening mammography. A number of different detector technologies exist, which all have their specific advantages and disadvantages. Diagnostic accuracy of digital mammography has been shown to be at least equivalent to film-screen mammography in a general screening population. Digital mammography is superior to screen-film mammography in younger women with dense breasts due to its ability to selectively optimize contrast in areas of dense parenchyma. This advantage is especially important in women with a genetic predisposition for breast cancer, where intensified early detection programs may have to start from 25 to 30 years of age. Tailored image processing and computer-aided diagnosis hold the potential to further improve the early detection of breast cancer. However, at present no consensus exists among radiologists on which processing is optimal for digital mammograms. Image processing may also vary significantly among vendors with so far limited interoperability. This review aims to summarize the available information regarding the impact of digital mammography on workflow and breast cancer diagnosis. (orig.)

  13. Determinants of mammography screening behavior in Iranian women: A population-based study

    Directory of Open Access Journals (Sweden)

    Mitra Moodi

    2012-01-01

    Full Text Available Background: Breast cancer remains a substantial health concern in Iran due to delay and late stage at diagnosis and treatment. Despite the potential benefits of mammography screening for early detection of breast cancer, the performance of this screening among Iranian women is low. For planning appropriate intervention, this study was carried out to identify mammography rates and explore determinants of mammography screening behavior in females of Isfahan, Iran. Materials and Methods: In this population-based study, 384 women of 40 years and older were interviewed by telephone. The Farsi version of Champion′s Health Belief Model scale (CHBMS was used to examine factors associated with mammography screening. The obtained data were analyzed by SPSS (version 16.0 using statistical Chi-square, Fisher Exact test, t-test and multiple logistic regression model to identify the importance rate of socio-demographic and Health Belief Model (HBM variables to predict mammography screening behavior. In all of tests, the level of significant was considered a = 0.05. Results: Mean age ΁ SD of women was 52.24 ΁ 8.2 years. Of the 384 participants, 44.3% reported at least one mammogram in their lifetime. Logistic regression analysis indicated that women were more likely to have mammography if they heard/read about breast cancer (OR = 4.17, 95% CI 2.09, 8.34, menopause in lower age (OR = 0.2, 95% CI 0.87, 0.99 and history of breast problem (OR = 0.9, 95% CI 0.12, 0.32. Also, women who perceived more benefits of mammography (OR = 1.84, 95% CI 1.63, 2.09, fewer barriers of mammography (OR = 0.91, 95% CI 0.86, 0.96 and had more motivation for health (OR = 0.94, 95% CI 0.89, 1 were more likely to have mammography. Conclusion: The findings indicated that the rate of mammography screening among women in Isfahan province is low and highlights the need for developing a comprehensive national breast cancer control program, which should be considered as the first

  14. Ultrasound as an Adjunct to Mammography for Breast Cancer Screening: A Health Technology Assessment

    Science.gov (United States)

    Nikitovic-Jokic, Milica; Tu, Hong Anh; Palimaka, Stefan; Higgins, Caroline; Holubowich, Corinne

    2016-01-01

    Background Screening with mammography can detect breast cancer early, before clinical symptoms appear. Some cancers, however, are not captured with mammography screening alone. Ultrasound has been suggested as a safe adjunct screening tool that can detect breast cancers missed on mammography. We investigated the benefits, harms, cost-effectiveness, and cost burden of ultrasound as an adjunct to mammography compared with mammography alone for screening women at average risk and at high risk for breast cancer. Methods We searched Ovid MEDLINE, Ovid Embase, EBM Reviews, and the NHS Economic Evaluation Database, from January 1998 to June 2015, for evidence of effectiveness, harms, diagnostic accuracy, and cost-effectiveness. Only studies evaluating the use of ultrasound as an adjunct to mammography in the specified populations were included. We also conducted a cost analysis to estimate the costs in Ontario over the next 5 years to fund ultrasound as an adjunct to mammography in breast cancer screening for high-risk women who are contraindicated for MRI, the current standard of care to supplement mammography. Results No studies in average-risk women met the inclusion criteria of the clinical review. We included 5 prospective, paired cohort studies in high-risk women, 4 of which were relevant to the Ontario context. Adjunct ultrasound identified between 2.3 and 5.9 additional breast cancers per 1,000 screens. The average pooled sensitivity of mammography and ultrasound was 53%, a statistically significant increase relative to mammography alone (absolute increase 13%; P screening alone. The GRADE for this body of evidence was low. Additional annual costs of using breast ultrasound as an adjunct to mammography for high-risk women in Ontario contraindicated for MRI would range from $15,500 to $30,250 in the next 5 years. Conclusions We found no evidence that evaluated the comparative effectiveness or diagnostic accuracy of screening breast ultrasound as an adjunct to

  15. Mammographic findings of women recalled for diagnostic work-up in digital versus screen-film mammography in a population-based screening program

    International Nuclear Information System (INIS)

    Lipasti, Seppo; Pamilo, Martti; Anttila, Ahti

    2010-01-01

    Background: Limited information is available concerning differences in the radiological findings of women recalled for diagnostic work-up in digital mammography (DM) versus screen-film mammography (SFM) screening. Purpose: To compare the radiological findings, their positive predictive values (PPVs) for cancer and other process indicators of DM screening performed by computed radiography (CR) technology and SFM screening in a population-based program. Material and Methods: The material consisted of women, 50-59 years of age, who were invited for screening: 30 153 women with DM in 2007-2008 and 32 939 women with SFM in 1999-2000. The attendance rate was 77.7% (23 440) in the DM arm and 83.8% (27 593) in the SFM arm. In the DM arm, 1.71% of those screened (401) and in the SFM arm 1.59% (438) were recalled for further work-up. The images resulting in the recall were classified as: 1) tumor-like mass, 2) parenchymal distortion/asymmetry, 3) calcifications, and 4) combination of mass and calcifications. The distributions of the various radiological findings and their PPVs for cancer were compared in both study groups. The recall rates, cancer detection rates, test specificities, and PPVs of the DM and SFM groups were also compared. Results: Women were recalled for diagnostic work-up most often due to tumor-like mass. It was more common in SFM (1.08% per woman screened) than in DM (0.93%). The second most common finding was parenchymal distortion and asymmetry, more often in DM (0.58%) than in SFM (0.37%). Calcifications were the third most common finding. DM exposed calcifications more often (0.49%) than SFM (0.26%). The PPVs for cancer of the recalls were higher in DM than in SFM in all subgroups of radiological findings. The test specificities were similar (DM 98.9%, SFM 98.8%). Significantly more cancers were detected by DM (cancer detection rate 0.623% per woman screened, n=146) than by SFM (cancer detection rate 0.406% per woman screened, n=112). The PPVs for

  16. Is mammography screening history a predictor of future breast cancer risk?

    DEFF Research Database (Denmark)

    Andersen, Sune Bangsbøll; Törnberg, Sven; Kilpeläinen, Sini

    2015-01-01

    Inspired by the model by Walter and Day for risk of cervical cancer following negative screens, one might hypothesize that women in a mammography screening programme with a certain number of negative screens had a lower remaining breast cancer risk than that of women in general. We studied whether...... number of negative screens was a predictor for a low remaining breast cancer risk in women participating in the mammography screening programmes in Stockholm, Copenhagen and Funen. Data were collected from the mammography screening programmes in Stockholm, Sweden (1989-2012), Copenhagen, Denmark (1991......-2009) and Funen, Denmark (1993-2009), and linked to the respective cancer registries. We calculated cumulative hazard rates for breast cancer in women in cohorts defined by age at entry and number of negative screens for the maximum follow-up period in each screening centre. For all centres and cohorts...

  17. [Mammography screening of breast cancer in Tunisia. Results of first experience].

    Science.gov (United States)

    Kribi, Lilia; Sellami, Dorra; el Amri, Aïda; Mnif, Nejla; Ellouze, Thouraya; Chebbi, Ali; Ben Romdhane, Khaled; Hamza, Radhi

    2003-01-01

    This article reports the results of a mammography screening program of breast cancer, realized in the department of Radiology, Charles Nicolle hospital. A free screening mammography with two incidences was offered to women aged from 40 to 70 years old. 2200 mammographies were realized from May 1995 till July 1997. Women having a positive test benefited of a diagnostic explorations in the same unity. The positive test rate was 24%. Predictive positive value was 31%. This program allowed to detect 10 subclinical cancers, corresponding to a rate of detection of 4.5 cancers for 1000 women. This program is a first experience which demonstrated the feasibility of the mammography screening to wide scale and allowed the medical and paramedical team to acquire an experience.

  18. Mammography and mammographic screening in the United Kingdom: Practices, regulations and radiation dosimetry

    International Nuclear Information System (INIS)

    Fitzgerald, M.

    1987-01-01

    The radiation-induced cancers due to mammography represent about 0.6 % of the natural incidence in this survey and would seem to be a very small risk. If the frequency or period of screening was increased, the risk would be enhanced. However, it should be possible to reduce the radiation dose to less than the mean value used here. For example, if film screen mammography alone was used for this population, the quoted risk would be reduced by 25%. The dose is also reduced by the use of a single view. The relatively low risk to the breast is a consequence partly of the low dose mammographic techniques that can now be practised, and partly of the acceptance of mean breast dose, which may be an order to magnitude less than the surface dose, as the measure of risk. The risk to other organs should be negligible provided that the X-ray field is carefully collimated and that the breast table incorporates a primary absorber

  19. Promoting mammography screening among Chinese American women using a message-framing intervention.

    Science.gov (United States)

    Sun, Yiyuan; Sarma, Elizabeth A; Moyer, Anne; Messina, Catherine R

    2015-07-01

    This study examined the role of women's perceptions about the relative pros versus cons (decisional balance) of mammography in moderating Chinese American women's responses to gain- and loss-framed messages that promote mammography. One hundred and forty-three Chinese American women who were currently nonadherent to guidelines for receiving annual screening mammograms were randomly assigned to read either a gain- or loss-framed culturally appropriate print brochure about mammography screening. Mammography screening was self-reported at a 2-month follow-up. Although there was not a main effect for message frame, the hypothesized interaction between message frame and decisional balance was significant, indicating that women who received a framed message that matched their decisional balance were significantly more likely to have obtained a mammogram by the follow-up than women who received a mismatched message. Results suggest that decisional balance, and more generally, perceptions about mammography, may be an important moderator of framing effects for mammography among Chinese American women. The match between message frame and decisional balance should be considered when attempting to encourage Chinese American women to receive mammography screening, as a match between the two may be most persuasive. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.

  20. A method for calculating effective lifetime risk of radiation-induced cancer from screening mammography

    International Nuclear Information System (INIS)

    Ali, R.M.; England, A.; McEntee, M.F.; Hogg, P.

    2015-01-01

    Purpose: To propose a method for evaluating the effective lifetime risk of radiation-induced cancer from screening mammography and to present initial data for the UK National Breast Screening Programme. Material and methods: The imaging was undertaken using a Hologic Selenia full field digital mammographic unit. The proposed method utilises an ATOM phantom containing thermoluminescent dosimeters and a perspex-polyethylene breast phantom to measure organ doses during a standard four view screening mammogram. Effective dose was calculated and effective risk was modelled for a range of client ages. The total lifetime effective risk was then calculated for the UK national screening programme. Calculation of effective risk includes the radiation dose to examined and contralateral breasts in addition to other body organs; this is an advantage over the mean glandular dose. Results: The contralateral breast, thyroid, thymus, brain, lung, salivary glands, and bone marrow all receive more than 1 μGy radiation dose during screening mammography. A major difference exists for total effective lifetime risk of radiation-induced cancer between clients with average and high breast cancer risk. Differences are attributed to the commencement age of screening and time interval between screens. Conclusion: This study proposes a method to evaluate effective lifetime risk of radiation-induced cancer from screening mammography in order to compare different mammography screening programmes. - Highlights: • We proposed a method for the calculation of radiation-induced cancer from screening mammography. • We measured the radiation absorbed dose of different organs during screening mammography. • There are major differences between mammography screening programme categories with regard to radiation effective risk.

  1. Follow-up and Final Results of the Oslo I Study Comparing Screen-Film Mammography and Full-field Digital Mammography with Soft-Copy Reading

    International Nuclear Information System (INIS)

    Skaane, P.; Skjennald, A.; Young, K.

    2005-01-01

    Purpose: To compare cancer detection rates of screen-film (SFM) and full-field digital mammography (FFDM) with soft-copy reading in a screening program including the initial positive scores for interval cancers and cancers in the subsequent screening round, and to analyze the false-negative FFDM interpretations. Material and Methods: Using a paired study design, 3683 women underwent SFM and FFDM in a population-based screening program. Two standard views of each breast were acquired. The images were interpreted without previous films for comparison. Independent double reading using a 5-point rating scale for probability of cancer was used for each modality. An examination was defined as positive if at least one of the two independent readers scored 2 or higher on the 5-point rating scale. SFM-positive cases were discussed in a SFM consensus meeting and FFDM-positive cases in a separate FFDM consensus meeting before recall. The study population was followed for more than 2 years so that interval cancers and screen-detected cancers in the subsequent screening round could be included. Cancer detection rates were compared using the McNemar test for paired proportions. The kappa statistic and Wilcoxon signed-rank test for matched pairs were used for comparing rating scores. The reading time was recorded for all FFDM interpretations. Results: A total of 31 cancers (detection rate 0.84%) were diagnosed initially, of which SFM detected 28 and FFDM 23 (McNemar test P 0.23, discordant pair 8 and 3). Two cancers with a positive score at initial SFM reading and three with a positive score at initial FFDM reading were dismissed at SFM and FFDM consensus meetings, respectively. The difference in cancer detection after recall (discordant pair 11 and 5) was not significant (McNemar test, P = 0.21). Of the 10 interval cancers and 16 screen-detected cancers in the subsequent round, 3 had true-positive SFM scores while 4 had true-positive FFDM scores in the initial reading session. A

  2. Follow-up and Final Results of the Oslo I Study Comparing Screen-Film Mammography and Full-field Digital Mammography with Soft-Copy Reading

    Energy Technology Data Exchange (ETDEWEB)

    Skaane, P.; Skjennald, A.; Young, K. [Ullevaal Univ. Hospital, Oslo (Norway). Dept. of Radiology] [and others

    2005-11-01

    Purpose: To compare cancer detection rates of screen-film (SFM) and full-field digital mammography (FFDM) with soft-copy reading in a screening program including the initial positive scores for interval cancers and cancers in the subsequent screening round, and to analyze the false-negative FFDM interpretations. Material and Methods: Using a paired study design, 3683 women underwent SFM and FFDM in a population-based screening program. Two standard views of each breast were acquired. The images were interpreted without previous films for comparison. Independent double reading using a 5-point rating scale for probability of cancer was used for each modality. An examination was defined as positive if at least one of the two independent readers scored 2 or higher on the 5-point rating scale. SFM-positive cases were discussed in a SFM consensus meeting and FFDM-positive cases in a separate FFDM consensus meeting before recall. The study population was followed for more than 2 years so that interval cancers and screen-detected cancers in the subsequent screening round could be included. Cancer detection rates were compared using the McNemar test for paired proportions. The kappa statistic and Wilcoxon signed-rank test for matched pairs were used for comparing rating scores. The reading time was recorded for all FFDM interpretations. Results: A total of 31 cancers (detection rate 0.84%) were diagnosed initially, of which SFM detected 28 and FFDM 23 (McNemar test P 0.23, discordant pair 8 and 3). Two cancers with a positive score at initial SFM reading and three with a positive score at initial FFDM reading were dismissed at SFM and FFDM consensus meetings, respectively. The difference in cancer detection after recall (discordant pair 11 and 5) was not significant (McNemar test, P = 0.21). Of the 10 interval cancers and 16 screen-detected cancers in the subsequent round, 3 had true-positive SFM scores while 4 had true-positive FFDM scores in the initial reading session. A

  3. The effects of gray scale image processing on digital mammography interpretation performance.

    Science.gov (United States)

    Cole, Elodia B; Pisano, Etta D; Zeng, Donglin; Muller, Keith; Aylward, Stephen R; Park, Sungwook; Kuzmiak, Cherie; Koomen, Marcia; Pavic, Dag; Walsh, Ruth; Baker, Jay; Gimenez, Edgardo I; Freimanis, Rita

    2005-05-01

    To determine the effects of three image-processing algorithms on diagnostic accuracy of digital mammography in comparison with conventional screen-film mammography. A total of 201 cases consisting of nonprocessed soft copy versions of the digital mammograms acquired from GE, Fischer, and Trex digital mammography systems (1997-1999) and conventional screen-film mammograms of the same patients were interpreted by nine radiologists. The raw digital data were processed with each of three different image-processing algorithms creating three presentations-manufacturer's default (applied and laser printed to film by each of the manufacturers), MUSICA, and PLAHE-were presented in soft copy display. There were three radiologists per presentation. Area under the receiver operating characteristic curve for GE digital mass cases was worse than screen-film for all digital presentations. The area under the receiver operating characteristic for Trex digital mass cases was better, but only with images processed with the manufacturer's default algorithm. Sensitivity for GE digital mass cases was worse than screen film for all digital presentations. Specificity for Fischer digital calcifications cases was worse than screen film for images processed in default and PLAHE algorithms. Specificity for Trex digital calcifications cases was worse than screen film for images processed with MUSICA. Specific image-processing algorithms may be necessary for optimal presentation for interpretation based on machine and lesion type.

  4. Statistical methods for determining the effect of mammography screening

    DEFF Research Database (Denmark)

    Lophaven, Søren

    2016-01-01

    In an overview of five randomised controlled trials from Sweden, a reduction of 29% was found in breast cancer mortality in women aged 50-69 at randomisation after a follow up of 5-13 years. Organised, population based, mammography service screening was introduced on the basis of these resultsin...... in 2007-2008. Women aged 50-69 were invited to screening every second year. Taking advantage of the registers of population and health, we present statistical methods for evaluating the effect of mammography screening on breast cancer mortality (Olsen et al. 2005, Njor et al. 2015 and Weedon-Fekjær etal...

  5. Mammography Screening Among African-American Women with a Family History of Breast Cancer

    National Research Council Canada - National Science Library

    Lipkus, Issac

    1997-01-01

    Comparisons were made between African-American women with and without a family history of breast cancer with respect to mammography screening, attitudes towards mammography screening and perceptions...

  6. Introduction of organised mammography screening in tyrol: results of a one-year pilot phase

    Directory of Open Access Journals (Sweden)

    Daniaux Martin

    2011-02-01

    Full Text Available Abstract Background Efficiency and efficacy of organised mammography screening programs have been proven in large randomised trials. But every local implementation of mammography screening has to check whether the well established quality standards are met. Therefore it was the aim of this study to analyse the most common quality indices after introducing organised mammography screening in Tyrol, Austria, in a smooth transition from the existing system of opportunistic screening. Methods In June 2007, the system of opportunistic mammography screening in Tyrol was changed to an organised system by introducing a personal invitation system, a training program, a quality assurance program and by setting up a screening database. All procedures are noted in a written protocol. Most EU recommendations for organised mammography screening were followed, except double reading. All women living in Tyrol and covered by social insurance are now invited for a mammography, in age group 40-59 annually and in age group 60-69 biannually. Screening mammography is offered mainly by radiologists in private practice. We report on the results of the first year of piloting organised mammography screening in two counties in Tyrol. Results 56,432 women were invited. Estimated participation rate was 34.5% at one year of follow-up (and 55.5% at the second year of follow-up; 3.4% of screened women were recalled for further assessment or intermediate screening within six months. Per 1000 mammograms nine biopsies were performed and four breast cancer cases detected (N = 68. Of invasive breast cancer cases 34.4% were ≤ 10 mm in size and 65.6% were node-negative. In total, six interval cancer cases were detected during one year of follow-up; this is 19% of the background incidence rate. Conclusions In the Tyrolean breast cancer screening program, a smooth transition from a spontaneous to an organised mammography screening system was achieved in a short time and with minimal

  7. Reader practice in mammography screen reporting in Australia

    International Nuclear Information System (INIS)

    Reed, W.; Poulos, A.; Brennan, P.

    2009-01-01

    Full text: Reader variability is a problem in mammography image reporting and compromises the efficacy of screening programmes. The purpose of this exploratory study was to survey reader practice in reporting screening mammograms in Australia to identify aspects of practice that warrant further investigation. Mammography reporting practice and influences on concentration and attention were investigated by using an original questionnaire distributed to screen readers in Australia. A response rate of 71% (83 out of 117) was achieved. Demographic data indicated that the majority of readers were over 46 years of age (73%), have been reporting on screening mammograms for over 10 years (61%), take less than 1 min to report upon a screening mammogram examination (66%), report up to 200 examinations in a single session (83%) and take up to 2 h to report one session (61%). A majority report on more than 5000 examinations annually (66%); 93% of participants regard their search strategy as systematic, 87% agreed that their concentration can vary throughout a session, 64% agreed that the relatively low number of positives can lead to lapses in concentration and attention and almost all (94%) participants agreed that methods to maximise concentration should be explored. Participants identified a range of influences on concentration within their working environment including volume of images reported in one session, image types and aspects of the physical environment. This study has provided important evidence of the need to investigate adverse influences on concentration during mammography screen reporting

  8. Information on mammography-screening - from deception to insight

    International Nuclear Information System (INIS)

    Muehlhauser, I.; Hoeldke, B.

    2002-01-01

    Information about mammography-screening as a basis for informed-decision making has to be evidence-based and presented in an unbiased format. This includes communication of results about effectiveness/lack of effectiveness of screening programmes (breast cancer mortality, total mortality), the quality of mammography as a screening test (sensitivity, specificity, positive and negative predictive values), and possible harm (consequences of false positive and false negative results, overdiagnosis of breast cancer, overtreatment). Outcome data have to be communicated as natural frequencies rather than relative differences. In order to avoid framing of data equal emphasis has to be put on the proportion of persons who are likely to benefit and those who are unlikely to benefit or likely to be harmed. (orig.) [de

  9. Screening mammography uptake within Australia and Scotland in rural and urban populations.

    Science.gov (United States)

    Leung, Janni; Macleod, Catriona; McLaughlin, Deirdre; Woods, Laura M; Henderson, Robert; Watson, Angus; Kyle, Richard G; Hubbard, Gill; Mullen, Russell; Atherton, Iain

    2015-01-01

    To test the hypothesis that rural populations had lower uptake of screening mammography than urban populations in the Scottish and Australian setting. Scottish data are based upon information from the Scottish Breast Screening Programme Information System describing uptake among women residing within the NHS Highland Health Board area who were invited to attend for screening during the 2008 to 2010 round (N = 27,416). Australian data were drawn from the 2010 survey of the 1946-51 cohort of the Australian Longitudinal Study on Women's Health (N = 9890 women). Contrary to our hypothesis, results indicated that women living in rural areas were not less likely to attend for screening mammography compared to women living in urban areas in both Scotland (OR for rural = 1.17, 95% CI = 1.06-1.29) and Australia (OR for rural = 1.15, 95% CI = 1.01-1.31). The absence of rural-urban differences in attendance at screening mammography demonstrates that rurality is not necessarily an insurmountable barrier to screening mammography.

  10. Addition of tomosynthesis to conventional digital mammography: effect on image interpretation time of screening examinations.

    Science.gov (United States)

    Dang, Pragya A; Freer, Phoebe E; Humphrey, Kathryn L; Halpern, Elkan F; Rafferty, Elizabeth A

    2014-01-01

    To determine the effect of implementing a screening tomosynthesis program on real-world clinical performance by quantifying differences between interpretation times for conventional screening mammography and combined tomosynthesis and mammography for multiple participating radiologists with a wide range of experience in a large academic center. In this HIPAA-compliant, institutional review board-approved study, 10 radiologists prospectively read images from screening digital mammography or screening combined tomosynthesis and mammography examinations for 1-hour-long uninterrupted sessions. Images from 3665 examinations (1502 combined and 2163 digital mammography) from July 2012 to January 2013 were interpreted in at least five sessions per radiologist per modality. The number of cases reported during each session was recorded for each reader. The experience level for each radiologist was also correlated to the average number of cases reported per hour. Analysis of variance was used to assess the number of studies interpreted per hour. A linear regression model was used to evaluate correlation between breast imaging experience and time taken to interpret images from both modalities. The mean number of studies interpreted in hour was 23.8 ± 0.55 (standard deviation) (range, 14.4-40.4) for combined tomosynthesis and mammography and 34.0 ± 0.55 (range, 20.4-54.3) for digital mammography alone. A mean of 10.2 fewer studies were interpreted per hour during combined tomosynthesis and mammography compared with digital mammography sessions (P tomosynthesis and mammography and 1.9 minutes ± 0.6 (range, 1.1-3.0) for digital mammography; interpretation time with combined tomosynthesis and mammography was 0.9 minute longer (47% longer) compared with digital mammography alone (P tomosynthesis and mammography examinations decreased (R(2) = 0.52, P = .03). Addition of tomosynthesis to mammography results in increased time to interpret images from screening examinations compared

  11. Mammography Clinical Image Quality and the False Positive Rate in a Canadian Breast Cancer Screening Program.

    Science.gov (United States)

    Guertin, Marie-Hélène; Théberge, Isabelle; Zomahoun, Hervé Tchala Vignon; Dufresne, Michel-Pierre; Pelletier, Éric; Brisson, Jacques

    2018-05-01

    The study sought to determine if mammography quality is associated with the false positive (FP) rate in the Quebec breast cancer screening program in 2004 and 2005. Mammography quality of a random sample of screen-film mammograms was evaluated by an expert radiologist following the criteria of the Canadian Association of Radiologists. For each screening examination, scores ranging from 1 (poor quality) to 5 (excellent quality) were attributed for positioning, compression, contrast, exposure level, sharpness, and artifacts. A final overall quality score (lower or higher) was also given. Poisson regression models with robust estimation of variance and adjusted for potential confounding factors were used to assess associations of mammography quality with the FP rate. Among 1,209 women without cancer, there were 104 (8.6%) FPs. Lower overall mammography quality is associated with an increase in the FP rate (risk ratio [RR], 1.4; 95% confidence interval [CI], 1.0-2.1; P = .07) but this increase was not statistically significant. Artifacts were associated with an increase in the FP rate (RR, 2.1; 95% CI, 1.3-3.3; P = .01) whereas lower quality of exposure level was related to a reduction of the FP rate (RR, 0.4; 95% CI, 0.1-1.0; P = .01). Lower quality scores for all other quality attributes were related to a nonstatistically significant increase in the FP rate of 10%-30%. Artifacts can have a substantial effect on the FP rate. The effect of overall mammography quality on the FP rate may also be substantial and needs to be clarified. Copyright © 2017 Canadian Association of Radiologists. Published by Elsevier Inc. All rights reserved.

  12. Comparison between film-screen and computed radiography systems in Brazilian mammography

    International Nuclear Information System (INIS)

    Vieira, L.A.; Oliveira, J.R.; Carvalho, L.A.P.; César, A.C.Z.; Nogueira, M.S.

    2015-01-01

    Since 2004 the Public Health Office of the State of Minas Gerais in Brazil has established the Image Quality Control Program in Mammography. It evaluates the image quality based on an accredited phantom of the Brazilian College of Radiology (CBR). This phantom follows international standards such as masses, specks, fibers, contrast details and spatial resolution. The contrast index (CI) is accessed through optical density (OD) measurements. Although OD is defined under film-screen (FS) scope, among all accessible mammographic systems under the health office surveillance, almost 80% are computed radiography (CR) based. A necessity to adapt the protocol has emerged to consider OD as a conformity parameter. Objective: To verify the OD accessibility under CR´s printed out films and the feasibility to calculate contrast index, in comparison with FS´s. Results: A total of 56 images were evaluated with three different CBR phantoms. They were equally divided into FS and CR systems and a densitometer was used to read out their OD values. The correlation between their contrast-to-noise ratio (CNR) was found to be in the order of 0.77 (±0.14). The samples were not significantly different (inside 5% incertitude) for every phantom. The CNR correlation coefficient was 0.871. For OD, correlation coefficient was 0.989 and a log-fit function has shown good agreement with detector response. The OD-normalized standard deviation difference between CR and FS for every different phantom was 36.6%, 2.8% and 20.2%. A CI range for CR´s lying between 0.13 and 0.69 was found. Conclusions: Different phantoms were successfully tested in both CR and FS to evaluate the feasibility in use contrast index as a conformity parameter since their correlations are strictly related to calibration curve, as provided by phantom manufacturer. The relative CR-FS OD σ-difference provides a spreading indicator, where the first and last phantoms are considerably out of expectation. Such differences are

  13. A study of some technical essentials of X-ray mammography

    International Nuclear Information System (INIS)

    Cao Houde; Jiang Qin

    2000-01-01

    Objective: To improve the quality of mammography and diagnostic accuracy by analyzing and studying some of the technical essentials of X-ray mammography. Methods: The mammography quality of 21 hospitals were investigated. The image quality of normal intensifying screen-film combination was tested and compared with computerized mammography. The filming positions and operating skills were studied. Results: The important mammography details that were displayed have low conformity with the diagnostic requirements, mainly due to non-conformity of these equipment to the requirements. The optimal pressure suitable for mammography of the Chinese women was around 12 kg. Conclusion: Necessary attention must be paid to the improvement of imaging features of these equipment. The improved operating skills will greatly raise the detecting percentage of pathological changes of breasts

  14. Efficacy of computer-aided detection system for screening mammography

    International Nuclear Information System (INIS)

    Saito, Mioko; Ohnuki, Koji; Yamada, Takayuki; Saito, Haruo; Ishibashi, Tadashi; Ohuchi, Noriaki; Takahashi, Shoki

    2002-01-01

    A study was conducted to evaluate the efficacy of a computer-aided detection (CAD) system for screening mammography (MMG). Screening mammograms of 2,231 women aged over 50 yr were examined. Medio-lateral oblique (MLO) images were obtained, and two expert observers interpreted the mammograms by consensus. First, each mammogram was interpreted without the assistance of CAD, followed immediately by a re-evaluation of areas marked by the CAD system. Data were recorded to measure the effect of CAD on the recall rate, cancer detection rate and detection rate of masses, microcalcifications and other findings. The CAD system increased the recall rate from 2.3% to 2.6%. Six recalled cases were diagnosed as breast cancer pathologically, and CAD detected all of these lesions. Seven additional cases in which CAD detected abnormal findings had no malignancy. The detection rate of CAD for microcalcifications was high (95.0%). However, the detection rate for mass lesions and other findings was low (29.2% and 25.0% respectively). The false positivity rate was 0.13/film for microcalcifications, and 0.25/film for mass lesions. The efficacy of the CAD system for detecting microcalcifications on screening mammograms was confirmed. However, the low detection rate of mass lesions and relatively high rate of false positivity need to be further improved. (author)

  15. Interval breast cancers in the 'screening with tomosynthesis or standard mammography' (STORM) population-based trial.

    Science.gov (United States)

    Houssami, Nehmat; Bernardi, Daniela; Caumo, Francesca; Brunelli, Silvia; Fantò, Carmine; Valentini, Marvi; Romanucci, Giovanna; Gentilini, Maria A; Zorzi, Manuel; Macaskill, Petra

    2018-04-01

    The prospective 'screening with tomosynthesis or standard mammography' (STORM) trial recruited women participating in biennial breast screening in Italy (2011-2012), and compared sequential screen-readings based on 2D-mammography alone or based on tomosynthesis (integrated 2D/3D-mammography). The STORM trial showed that tomosynthesis screen-reading significantly increased breast cancer detection compared to 2D-mammography alone. The present study completes reporting of the trial by examining interval breast cancers ascertained at two year follow-up. 9 interval breast cancers were identified; the estimated interval cancer rate was 1.23/1000 screens [9/7292] (95%CI 0.56 to 2.34) or 1.24/1000 negative screens [9/7235] (95%CI 0.57 to 2.36). In concurrently screened women who attended the same screening services and received 2D-mammography, interval cancer rate was 1.60/1000 screens [40/25,058] (95% CI 1.14 to 2.17) or 1.61/1000 negative screens [40/24,922] (95% CI 1.15 to 2.18). Estimated screening sensitivity for the STORM trial was 85.5% [59/69] (95%CI 75.0%-92.8%), and that for 2D-mammography screening was 77.3% [136/176] (95%CI 70.4%-83.2%). Interval breast cancer rate amongst screening participants in the STORM trial was marginally lower (and screening sensitivity higher) than estimates amongst 2D-screened women; these findings should be interpreted with caution given the small number of interval cases and the sample size of the trial. Much larger screening studies, or pooled analyses, are required to examine interval cancer rates arising after breast tomosynthesis screening versus digital mammography screening. Copyright © 2018 Elsevier Ltd. All rights reserved.

  16. Quality control for digital mammography: Part II recommendations from the ACRIN DMIST trial

    International Nuclear Information System (INIS)

    Yaffe, Martin J.; Bloomquist, Aili K.; Mawdsley, Gordon E.

    2006-01-01

    The Digital Mammography Imaging Screening Trial (DMIST), conducted under the auspices of the American College of Radiology Imaging Network (ACRIN), is a clinical trial designed to compare the accuracy of digital versus screen-film mammography in a screening population [E. Pisano et al., ACRIN 6652--Digital vs. Screen-Film Mammography, ACRIN (2001)]. Part I of this work described the Quality Control program developed to ensure consistency and optimal operation of the digital equipment. For many of the tests, there were no failures during the 24 months imaging was performed in DMIST. When systems failed, they generally did so suddenly rather than through gradual deterioration of performance. In this part, the utility and effectiveness of those tests are considered. This suggests that after verification of proper operation, routine extensive testing would be of minimal value. A recommended set of tests is presented including additional and improved tests, which we believe meet the intent and spirit of the Mammography Quality Standards Act regulations to ensure that full-field digital mammography systems are functioning correctly, and consistently producing mammograms of excellent image quality

  17. Radiation dose during mammography using various recording systems

    International Nuclear Information System (INIS)

    Heep, H.; Buelow-Johansen, T.; Klemencic, J.; Wegwitz, J.; Stadtkrankenhaus Offenbach

    1978-01-01

    Patient dose during mammography for various recording systems, such as film, film-screen combination and xeromammography was measured by thermoluminescent densitometers. In the first set of experiments we measured dose per exposure, in a second set total surface dose at five points on the breast, using the following combintions: a) Two industrial film exposures and one xeromammographic exposure. b) two film-screen exposures and one xeromammographic exposure. c) One industrial film and two xeromammographic exposures. (orig.) [de

  18. Screening mammography among nursing home residents in the United States: Current guidelines and practice.

    Science.gov (United States)

    Mack, Deborah S; Epstein, Mara M; Dubé, Catherine; Clark, Robin E; Lapane, Kate L

    2018-06-04

    United States (US) guidelines regarding when to stop routine breast cancer screening remain unclear. No national studies to-date have evaluated the use of screening mammography among US long-stay nursing home residents. This cross-sectional study was designed to identify prevalence, predictors, and geographic variation of screening mammography among that population in the context of current US guidelines. Screening mammography prevalence, identified with Physician/Supplier Part B claims and stratified by guideline age classification (65-74, ≥75 years), was estimated for all women aged ≥65 years residing in US Medicare- and Medicaid- certified nursing homes (≥1 year) with an annual Minimum Data Set (MDS) 3.0 assessment, continuous Medicare Part B enrollment, and no clinical indication for screening mammography as of 2011 (n = 389,821). The associations between resident- and regional- level factors, and screening mammography, were estimated by crude and adjusted prevalence ratios from robust Poisson regressions clustered by facility. Women on average were 85.4 (standard deviation ±8.1) years old, 77.9% were disabled, and 76.3% cognitively impaired. Screening mammography prevalence was 7.1% among those aged 65-74 years (95% Confidence Interval (CI): 6.8%-7.3%) and 1.7% among those ≥75 years (95% CI, 1.7%-1.8%), with geographic variation observed. Predictors of screening in both age groups included race, cognitive impairment, frailty, hospice, and some comorbidities. These results shed light on the current screening mammography practices in US nursing homes. Thoughtful consideration about individual screening recommendations and the implementation of more clear guidelines for this special population are warranted to prevent overscreening. Copyright © 2018 Elsevier Inc. All rights reserved.

  19. Mammography in breast screening and in the evaluation and management of breast cancer

    International Nuclear Information System (INIS)

    Onyesoh, C.N.

    2006-01-01

    This paper aims to discuss the importance of breast screening most especially amongst women above the age of 40 years.the limitation of the screening procedure is due to lack of special machines and power awareness campaigns. the application of Mammography and ultrasound in the examination of the breast and other breast imaging techniques will be considered in this paper. The paper will look at the indications for mammography, indications for breast ultrasound, signs of breast carcinoma on mammography, breast enlargement and also the need for breast ultrasound in cases of discrete Mammography

  20. Comparative effectiveness of combined digital mammography and tomosynthesis screening for women with dense breasts.

    Science.gov (United States)

    Lee, Christoph I; Cevik, Mucahit; Alagoz, Oguzhan; Sprague, Brian L; Tosteson, Anna N A; Miglioretti, Diana L; Kerlikowske, Karla; Stout, Natasha K; Jarvik, Jeffrey G; Ramsey, Scott D; Lehman, Constance D

    2015-03-01

    To evaluate the effectiveness of combined biennial digital mammography and tomosynthesis screening, compared with biennial digital mammography screening alone, among women with dense breasts. An established, discrete-event breast cancer simulation model was used to estimate the comparative clinical effectiveness and cost-effectiveness of biennial screening with both digital mammography and tomosynthesis versus digital mammography alone among U.S. women aged 50-74 years with dense breasts from a federal payer perspective and a lifetime horizon. Input values were estimated for test performance, costs, and health state utilities from the National Cancer Institute Breast Cancer Surveillance Consortium, Medicare reimbursement rates, and medical literature. Sensitivity analyses were performed to determine the implications of varying key model parameters, including combined screening sensitivity and specificity, transient utility decrement of diagnostic work-up, and additional cost of tomosynthesis. For the base-case analysis, the incremental cost per quality-adjusted life year gained by adding tomosynthesis to digital mammography screening was $53 893. An additional 0.5 deaths were averted and 405 false-positive findings avoided per 1000 women after 12 rounds of screening. Combined screening remained cost-effective (less than $100 000 per quality-adjusted life year gained) over a wide range of incremental improvements in test performance. Overall, cost-effectiveness was most sensitive to the additional cost of tomosynthesis. Biennial combined digital mammography and tomosynthesis screening for U.S. women aged 50-74 years with dense breasts is likely to be cost-effective if priced appropriately (up to $226 for combined examinations vs $139 for digital mammography alone) and if reported interpretive performance metrics of improved specificity with tomosynthesis are met in routine practice.

  1. Mammography screening in Greece: An exploratory survey of women's views, experiences and behaviours

    Directory of Open Access Journals (Sweden)

    Athena Kalokerinou

    2012-01-01

    Full Text Available Background: Internationally, breast cancer comprises 29% of all cancer incidences. In Greece, 1,500-1,800women die annually from breast cancer out of the 4,000 who are affected. Only 5% are detected at an early diseasestage through mammography screening.Aim: This paper presents findings from a study exploring the factors that influence Greek women’smammography screening behaviour.Methodology: Data were collected in Athens-Greece, during the period March-July 2008, from individuals whowere members of six women’s associations. One hundred and eighty six questionnaires were completed and 33interviews were conducted from a sub-sample. This paper reports the findings from the questionnaire survey.Results: Participants had a variety of demographic characteristics with 85% of them having attendedmammography screening. Only 61% of them intended to continue in the future. Τhe majority of women agreedwith a number of factors which supported their decision to participate in regular mammography screening, such asdoctors’ encouragement and mammogram efficacy to detect breast cancer at an early stage, while anxiety wasidentified as a possible inhibitor to their participation.Conclusion: Women’s mammography screening behaviour and perceptions of mammography screening appearedto be positive in relation to their participation. However, the reasons as to why a large number of women indicatedthey were unlikely to go for mammography screening again is not known, and needs further investigation.

  2. Breast cancer mortality in Norway after the introduction of mammography screening

    DEFF Research Database (Denmark)

    Olsen, Anne Helene; Lynge, Elsebeth; Njor, Sisse H

    2013-01-01

    An organized mammography screening program was gradually implemented in Norway during the period 1996-2004. Norwegian authorities have initiated an evaluation of the program. Our study focused on breast cancer mortality. Using Poisson regression, we compared the change in breast cancer mortality ...... to the program, the implementation of the organized mammography screening program was associated with a statistically nonsignificant decrease in breast cancer mortality of around 11%....

  3. An investigation into why two-view mammography is better than one-view in breast cancer screening

    International Nuclear Information System (INIS)

    Hackshaw, A.K.; Wald, N.J.; Michell, M.J.; Field, S.; Wilson, A.R.M.

    2000-01-01

    AIM: To determine why two-view mammography in screening for breast cancer is more effective than using a single medio-lateral oblique view. MATERIALS AND METHODS: In the United Kingdom Coordinating Committee on Cancer Research randomized trial of one- vs two-view mammography in breast cancer screening the oblique view was assessed by one radiologist and two views (oblique and cranio-caudal) assessed by another. For the present study the mammographic films were retrieved from the screening centres and assessed by three consultant radiologists. Mammographic films were available from 110 women; 87 had their breast cancer detected by both one and two views and in 23 it was missed by one view but detected using two views. Outcome measures were breast size, location and size of the cancer, mammographic features, presence of microcalcification and overall radiological assessment. RESULTS: Although 23 cancers were missed in the original trial when one view was used, only two were not visible on the oblique view. Cancers missed using a single oblique view (and only detected if the cranio-caudal view was available with the oblique) tended to be smaller by about 4 mm (P = 0.05), centrally located in the breast (P = 0.16), not spiculated or round, (P ≤ 0.001) and lacked microcalcification (P = 0.15). Breast size and breast radiographic density were not significantly associated with breast cancer detection. CONCLUSIONS: The results provide the basis for the observation that two-view mammographic screening is more effective than one-view mammographic screening. Hackshaw, A. (2000). Clinical Radiology 55, 454-458

  4. Implementation of Synthesized Two-dimensional Mammography in a Population-based Digital Breast Tomosynthesis Screening Program

    Science.gov (United States)

    Zuckerman, Samantha P.; Keller, Brad M.; Maidment, Andrew D. A.; Barufaldi, Bruno; Weinstein, Susan P.; Synnestvedt, Marie; McDonald, Elizabeth S.

    2016-01-01

    Purpose To evaluate the early implementation of synthesized two-dimensional (s2D) mammography in a population screened entirely with s2D and digital breast tomosynthesis (DBT) (referred to as s2D/DBT) and compare recall rates and cancer detection rates to historic outcomes of digital mammography combined with DBT (referred to as digital mammography/DBT) screening. Materials and Methods This was an institutional review board–approved and HIPAA-compliant retrospective interpretation of prospectively acquired data with waiver of informed consent. Compared were recall rates, biopsy rates, cancer detection rates, and radiation dose for 15 571 women screened with digital mammography/DBT from October 1, 2011, to February 28, 2013, and 5366 women screened with s2D/DBT from January 7, 2015, to June 30, 2015. Two-sample z tests of equal proportions were used to determine statistical significance. Results Recall rate for s2D/DBT versus digital mammography/DBT was 7.1% versus 8.8%, respectively (P < .001). Biopsy rate for s2D/DBT versus digital mammography/DBT decreased (1.3% vs 2.0%, respectively; P = .001). There was no significant difference in cancer detection rate for s2D/DBT versus digital mammography/DBT (5.03 of 1000 vs 5.45 of 1000, respectively; P = .72). The average glandular dose was 39% lower in s2D/DBT versus digital mammography/DBT (4.88 mGy vs 7.97 mGy, respectively; P < .001). Conclusion Screening with s2D/DBT in a large urban practice resulted in similar outcomes compared with digital mammography/DBT imaging. Screening with s2D/DBT allowed for the benefits of DBT with a decrease in radiation dose compared with digital mammography/DBT. © RSNA, 2016 An earlier incorrect version of this article appeared online. This article was corrected on August 11, 2016. PMID:27467468

  5. Using Mammography Screening: Hmong Women’s Perceptions and Beliefs

    Directory of Open Access Journals (Sweden)

    Pang Vang

    2010-01-01

    Full Text Available Breast cancer is the second leading cause of cancer deaths among all women in the United States. Although mammography screening has been shown to be effective in detecting breast cancer, Hmong women, one of the Asian American/Pacific Islander subgroups, have a very low screening rate. The purpose of this study was to explore factors that influence Hmong women‘s willingness to be screened for breast cancer. Grounded Theory methodology guided the analysis of fifteen qualitative interviews with Midwestern Hmong women between the ages of40-64. Regardless of age, length of US residency, and language spoken, the results showed one core theme and three interrelated themes regarding the women‘s decision to seek mammographyscreening. The three interrelated themes of Breast Health Messages, Screening Barriers, and Screening Facilitators can have negative and/or positive influences on the core theme of mammography-screening decision-making processes. The first related theme of Breast HealthMessages included professional and lay breast health messages. The second related theme, Screening Facilitators, included breast health messages from professionals, abnormal findings, social support, risk for getting breast cancer, doctor‘s recommendations, and insurance. The third related theme, Screening Barriers, identified symptomatic health seeking behavior, instrumental barriers, fear, social influence (which included lay breast health messages, use of traditional Hmong healing practices, embarrassment, and perception of breast cancer risk. This study suggested that the healthcare professionals need to use a culturally sensitive and multidisciplinaryapproach to provide breast health education as well as to assess and provide instrumental support, while encouraging social support to influence Hmong women to attain mammography screening.

  6. Contrast-enhanced spectral mammography in patients referred from the breast cancer screening programme.

    Science.gov (United States)

    Lobbes, Marc B I; Lalji, Ulrich; Houwers, Janneke; Nijssen, Estelle C; Nelemans, Patty J; van Roozendaal, Lori; Smidt, Marjolein L; Heuts, Esther; Wildberger, Joachim E

    2014-07-01

    Feasibility studies have shown that contrast-enhanced spectral mammography (CESM) increases diagnostic accuracy of mammography. We studied diagnostic accuracy of CESM in patients referred from the breast cancer screening programme, who have a lower disease prevalence than previously published papers on CESM. During 6 months, all women referred to our hospital were eligible for CESM. Two radiologists blinded to the final diagnosis provided BI-RADS classifications for conventional mammography and CESM. Statistical significance of differences between mammography and CESM was calculated using McNemar's test. Receiver operating characteristic (ROC) curves were constructed for both imaging modalities. Of the 116 eligible women, 113 underwent CESM. CESM increased sensitivity to 100.0% (+3.1%), specificity to 87.7% (+45.7%), PPV to 76.2% (+36.5%) and NPV to 100.0% (+2.9%) as compared to mammography. Differences between conventional mammography and CESM were statistically significant (p mammography, AUC was 0.779. With CESM, AUC increased to 0.976 (p mammography, even in lower prevalence patient populations such as referrals from breast cancer screening. • CESM is feasible in the workflow of referrals from routine breast screening. • CESM is superior to mammography, even in low disease prevalence populations. • CESM has an extremely high negative predictive value for breast cancer. • CESM is comparable to MRI in assessment of breast cancer extent. • CESM is comparable to histopathology in assessment of breast cancer extent.

  7. Studies on the calibration of mammography automatic exposure mode with computed radiology

    International Nuclear Information System (INIS)

    Zhu Hongzhou; Shao Guoliang; Shi Lei; Liu Qing

    2010-01-01

    Objective: To realize the optimization of image quality and radiation dose by correcting mammography automatic exposure, according to automatic exposure controlled mode of mammography film-screen system. Methods: The film-screen system (28 kV) was applied to perform automatic exposure of plexiglass (40 mm) and get the standard dose of exposure, the exposure mode of CR base on LgM=2.0 was rectified, which was divided into 10 steps. Mammary glands pattern (Fluke NA18-220) were examined with CR (26, 28, and 30 kV) by the automatic exposure mode corrected. The exposure values (mAs) were recorded. CR image was diagnosed and evaluated in double blind way by 4 radiologists according to American Collage of Radiology (ACR) standard. Results: Based on the standard of CR automatic exposure with the dose higher than the traditional exposure of film-screen system, the calibration of mammography automatic exposure was accomplished. The test results of the calibrated mode was better than the scoring system of ACR. Conclusions: Comparative study showed improvement in acquiring high-quality image and reduction of radiation dose. The corrected mammography automatic exposure mode might be a better method for clinical use. (authors)

  8. Reduction in interval cancer rates following the introduction of two-view mammography in the UK breast screening programme

    Science.gov (United States)

    Dibden, A; Offman, J; Parmar, D; Jenkins, J; Slater, J; Binysh, K; McSorley, J; Scorfield, S; Cumming, P; Liao, X-H; Ryan, M; Harker, D; Stevens, G; Rogers, N; Blanks, R; Sellars, S; Patnick, J; Duffy, S W

    2014-01-01

    Background: The introduction of two-view mammography at incident (subsequent) screens in the National Health Service Breast Screening Programme (NHSBSP) has led to an increased number of cancers detected at screen. However, the effect of two-view mammography on interval cancer rates has yet to be assessed. Methods: Routine screening and interval cancer data were collated from all screening programmes in the United Kingdom for women aged 50–64, screened between 1 April 2003 and 31 March 2005. Interval cancer rates were compared based on whether two-view mammography was in use at the last routine screen. Results: The reduction in interval cancers following screening using two-view mammography compared with one view was 0.68 per 1 000 women screened. Overall, this suggests the introduction of two-view mammography at incident screen was accompanied by a 15–20% reduction in interval cancer rates in the NHSBSP. Conclusion: The introduction of two-view mammography at incident screens is associated with a reduction in incidence of interval cancers. This is consistent with previous publications on a contemporaneous increase in screen-detected cancers. The results provide further evidence of the benefit of the use of two-view mammography at incident screens. PMID:24366303

  9. Cost-effective mammography screening in Korea. High incidence of breast cancer in young women

    International Nuclear Information System (INIS)

    Lee, Soon-Young; Jeong, Seong-Hwa; Kim, Youn-Nam; Kim, Jinheum; Kang, Dae-Ryong; Kim, Hyeon-Chang; Nam, Chung-Mo

    2009-01-01

    The epidemiological characteristics of breast cancer in Korean women are different from the characteristics reported in Western women. The highest incidence rate occurs in Korean women in their 40s. The purpose of this study was to determine the most cost-effective screening interval and target age range for Korean women from the perspective of the national healthcare system. A stochastic model was used to simulate breast cancer screenings by varying both the screening intervals and the age ranges. The effectiveness of mammography screening was defined as the probability of detecting breast cancer in the preclinical state and the cost was based on the direct cost of mammography screening and the confirmative tests. The age-specific mean sojourn times and the sensitivity of the mammography were applied in the stochastic model. An optimal cost-effectiveness was determined by the incremental cost-effectiveness ratio and lifetime schedule sensitivity. Sensitivity analyses were undertaken to assess parameter uncertainty. The selected cost-effective strategies were: the current biennial mammography screenings for women who are at least 40 years old; biennial screening for women between the ages of 35 and 75 years; and a combination strategy consisting of biennial screening for women aged between 45 and 54 years, and 3-year interval screening for women aged between 40 and 44 years and 55 and 65 years. Further studies should follow to investigate the effectiveness of mammography screening in women younger than 40 years in Asia as well as in Korea. (author)

  10. Screening mammography in a health promotion center for 5 years : results of medical audits

    International Nuclear Information System (INIS)

    Kim, Mi Hye; Lee, Mi Ja; Oh, Ki Keun; Lee, Kyong Sik

    2000-01-01

    The purpose of this study was to perform a medical audit of the screening of mammographic results according to ACR BI-RADS Follow-Up and Outcome Monitoring and to evaluate the efficacy of screening mammography in the early detection of breast cancer. We reviewed the results of 15,300 mammographic examinations of 13,889 women aged 30-75 years who underwent mammography at least once at the Severance Health Promotion Center between 1994-1998. Women with abnormal mammographic findings were recalled for additional study and those with dense breast composition (3, 4) underwent additional ultrasound. All results were categorized on the basis of the ACR BI-RADS final assessment scale, 1-5. We reviewed the pathologic or follow-up results of all women in categories 4 and 5, and/or those in any category who took the films out of the health center. The recall rate was 13%. Biopsy or surgical consultation was recommended for 92 women and biopsy was performed in 52. Pathology revealed 17 cancers and 35 benign lesions. Positive predictive value 2 was found in 18.5% of cases, and positive predictive value 3 in 33%. The cancer detection rate was 1.2/1,000, and sensitivity was 89.5%. Invasive cancers smaller than 1 cm or in situ ductal cancers were found in eight of 17 cases (47%), while node-positive invasive cancers were found in nine of 14 cases (64%). Four of 17 mammographically detected cancers were palpated by a surgeon. In asymptomatic women, screening mammography is an effective method for the detection of early breast cancer. (author)

  11. [Controversial attitude to mammography screening in asymptomatic women between 40 and 50 years of age].

    Science.gov (United States)

    Frischbier, H J

    1994-01-01

    The results of screening studies conducted in the United States and in Europe in females between the ages of 40 and 50 are analysed. It is shown, that the results of this study on mortality reduction are less favourable, the poorer the technique of mammography (foregoing of general two-view mammography) and the longer the time interval between two mammography screenings. Arguments are presented, that are brought forward when declining to perform general mammography screening in this age group. The author's own results, obtained in the Hamburg mammography screening study, which included from 1971 to 1986 also premenopausal women, show, that the survival rates of patients below 50 years of age with mammographically detected carcinomas of the breast do not differ from those in patients older than 50 years, according to a relevant age group classification. The advances in the technique of mammography in recent years are analysed on the basis of the author's own patient material. It is evident, that the positive predictive value has been doubled, especially in the age group between 40 and 50. An analysis of the distribution of diagnosed noninvasive carcinomas compared with the invasive carcinomas reveals, that particularly this age group has the highest percentage of identification of prognostically favourable carcinoma stages. Further analyses show, why the randomised European mammography studies could not yield a significant mortality rate improvement. A prerequisite for the inclusion of mammography screening in the legally prescribed early detection of carcinoma examinations, however, are the quality controls, whose realisation, in our health system, will have to be confirmed by the German mammography study.

  12. From facts to arguments: A study of the 2014 Swiss controversy over systematic mammography screening.

    Science.gov (United States)

    Perrenoud, Caroline; Stiefel, Friedrich; Bourquin, Céline

    2018-06-01

    The Swiss Medical Board (SMB) has recently revived the controversy over mammography screening by recommending to stop the introduction of new systematic mammography screening programs. This study aimed to examine the Swiss media coverage of the release of the SMB report. The dataset consisted of 25 newspaper and "medical magazine" articles, and TV/radio interviews. The analytic approach was based on argumentation theory. Authority and community arguments were the most frequent types of arguments. With respect to authority arguments, stakeholders for instance challenged or supported the expertise of the SMB by referring to the competence of external figures of authority. Community arguments were based on common values such as life (saved thanks to systematic mammography screening) and money (costs associated with unnecessary care induced by systematic mammography screening). The efficiency of mammography screening which was the key issue of the debate appeared to be largely eluded, and the question of what women should do endures. While interpersonal and interprofessional communication has become a major topic of interest in the medical community, it appears that media communication on mammography screening is still rather ineffective. We call in particular for a more fact-based discussion. Copyright © 2017 Elsevier B.V. All rights reserved.

  13. Digital mammography screening: average glandular dose and first performance parameters

    International Nuclear Information System (INIS)

    Weigel, S.; Girnus, R.; Czwoydzinski, J.; Heindel, W.; Decker, T.; Spital, S.

    2007-01-01

    Purpose: The Radiation Protection Commission demanded structured implementation of digital mammography screening in Germany. The main requirements were the installation of digital reference centers and separate evaluation of the fully digitized screening units. Digital mammography screening must meet the quality standards of the European guidelines and must be compared to analog screening results. We analyzed early surrogate indicators of effective screening and dosage levels for the first German digital screening unit in a routine setting after the first half of the initial screening round. Materials and Methods: We used three digital mammography screening units (one full-field digital scanner [DR] and two computed radiography systems [CR]). Each system has been proven to fulfill the requirements of the National and European guidelines. The radiation exposure levels, the medical workflow and the histological results were documented in a central electronic screening record. Results: In the first year 11,413 women were screened (participation rate 57.5 %). The parenchymal dosages for the three mammographic X-ray systems, averaged for the different breast sizes, were 0.7 (DR), 1.3 (CR), 1.5 (CR) mGy. 7 % of the screened women needed to undergo further examinations. The total number of screen-detected cancers was 129 (detection rate 1.1 %). 21 % of the carcinomas were classified as ductal carcinomas in situ, 40 % of the invasive carcinomas had a histological size ≤ 10 mm and 61 % < 15 mm. The frequency distribution of pT-categories of screen-detected cancer was as follows: pTis 20.9 %, pT1 61.2 %, pT2 14.7 %, pT3 2.3 %, pT4 0.8 %. 73 % of the invasive carcinomas were node-negative. (orig.)

  14. Estimation of mean glandular dose for patients who undergo mammography and studying the factors affecting it

    Science.gov (United States)

    Barzanje, Sana L. N. H.; Harki, Edrees M. Tahir Nury

    2017-09-01

    The objective of this study was to determine mean glandular dose (MGD) during diagnostic mammography. This study was done in two hospitals in Hawler city in Kurdistan -region /Iraq, the exposure parameters kVp and mAs was recorded for 40 patients under go mammography. The MGD estimated by multiplied ESD with normalized glandular dose (Dn). The ESD measured indirectly by measuring output radiation mGy/mAs by using PalmRAD 907 as a suitable detector (Gigger detector).the results; shown that the mean and its standard deviation of MGD for Screen Film Mammography and Digital Mammography are (0.95±0.18)mGy and (0.99±0.26)mGy, respectively. And there is a significant difference between MGD for Screen Film Mammography and Digital Mammography views (p≤0. 05). Also the mean value and its standard deviation of MGD for screen film mammography is (0.96±0.21) for CC projection and (1.03±0.3) mGy for MLO projection, but mean value and its standard deviation evaluated of MGD for digital mammography is (0.92±0.17) mGy for CC projection and (0.98±0.2) mGy for MLO projection. As well as, the effect of kVp and mAs in MGD were studied, shows that in general as kVp and mAs increased the MGD increased accordingly in both of mammography systems.

  15. Patient doses and radiation risks in film-screen mammography in Finland

    International Nuclear Information System (INIS)

    Servomaa, A.; Parviainen, T.; Komppa, T.

    1995-01-01

    Screen-film mamography is the most sensitive method for the early detection of breast cancer. Breast doses in mamography should be measured for several reasons, especially for the evaluation of patient risk in a screening programme, but also for the assessment and comparison of imaging techniques and equipment performance. In this study, the factors affecting patient doses were assessed by making performance and patient dose measurements; about 50 mammographic units used for screening were included in the study. The lifetime risk as a function of age at exposure was calculated using the average glandular dose, the relative risk model shown in the BEIR V report, and the breast cancer mortality in Finland. The mean surface dose of a 4.5 cm thick phantom was 6.3 mGy, and the mean glandular dose 1.0 mGy. Analysis of the surface dose with respect to film optical density, relative speed of film processing, sensitivity of image receptors, and antiscatter grid showed that the mean surface dose could be decreased by more than 50%. For the screened age group of 50 to 59 years, the risk of exposure-induced death (REID) of breast cancer is about 1.4 x 10 -6 mSv -1 , and the average loss of life expectancy due to the radiation-induced breast cancer deaths (LLE/REID) is about 9.5 years. (Author)

  16. Hardware for mammography

    International Nuclear Information System (INIS)

    Rozhkova, N.I.; Chikirdin, Eh.G.; Ryudiger, Yu.G.; Kochetova, G.P.; Lisachenko, I.V.; Yakobs, O.Eh.

    2000-01-01

    The comparative studies on various visualization means, in particular, the intensifying screens and films with application of quantitative methods for determining small details on photographs, including measurements of corresponding exposures, absorbed doses and verification of conclusions through the analysis of clinical observations are carried out. It is shown, that technical equipment of the modern mammography room should include the X-ray mammographic apparatus, providing for the image high-quality by low dose loads with special film holders, meeting the mammography requirements, the corresponding X-ray film and the automatic photolaboratory process, provided by one and the same company. The quality of photographs under such conditions is guarantied, the defects and errors by the image interpretation are excluded. The modern computerized information technologies for work with medical images on the basic of creating new generations of diagnostic instrumentation with digital video channels and computerized working places dispose of many medical, technological, organizational and financial problems [ru

  17. Breast Cancer Screening Coverage with clinical examination and Mammography Among insured women in Bogota

    International Nuclear Information System (INIS)

    Arboleda, Walter; Murillo Raul; Pinero, Marion

    2009-01-01

    The objective is to determine the coverage of clinical breast examination (CBE) and mammography for screening of breast cancer among a group of insured women in Bogota. Methods: A telephone survey was carried out with 4,526 women between the ages of 50 and 69, residing in Bogota or its suburbs, who were insured by one of three commercial health plans. Women with a history of breast cancer were excluded. Screening coverage was estimated as the proportion of women who had had a mammography or CBE. Estimates were established for lifetime frequency, two years prior the survey, and one year prior the survey. Factors associated with screening procedures were analyzed with calculations based on adjusted OR. Results: Lifetime frequency of CBE was 59.3% and 79.8% for mammography; and 49.7% and 65.6% of women respectively underwent the tests for screening purposes; the remainder, for diagnostic purposes (breast symptoms). CBE reported a 34.2% one year coverage and mammography reported a 54% two years coverage. Screening was associated to cancer education and family history of breast cancer. Conclusion: Coverage of CBE for screening purposes is low. Mammography coverage is above that required by the Colombian Health Ministry, but below that reported by developed countries.

  18. Characteristics and screening outcome of women referred twice at screening mammography

    International Nuclear Information System (INIS)

    Setz-Pels, Wikke; Duijm, Lucien E.M.; Jansen, Frits H.; Louwman, Marieke W.J.; Roumen, Rudi M.H.; Voogd, Adri C.

    2012-01-01

    To determine the characteristics and screening outcome of women referred twice at screening mammography. We included 424,703 consecutive screening mammograms and collected imaging, biopsy and surgery reports of women with screen-detected breast cancer. Review of screening mammograms was performed to determine whether or not an initial and second referral comprised the same lesion. The overall positive predictive value of referral for cancer was 38.6% (95% CI 37.3-39.8%). Of 147 (2.6%) women referred twice, 86 had been referred for a different lesion at second referral and 32 of these proved malignant (37.2%, 95% CI 27.0-47.4%). Sixty-one women had been referred twice for the same lesion, of which 22 proved malignant (36.1%, 95% CI 24.1-48.0%). Characteristics of these women were comparable to women with cancer diagnosed after first referral. Compared with women without cancer at second referral for the same lesion, women with cancer more frequently showed suspicious densities at screening mammography (86.4% vs 53.8%, P = 0.02) and work-up at first referral had less frequently included biopsy (22.7% vs 61.5%, P = 0.004). Cancer risk in women referred twice for the same lesion is similar to that observed in women referred once, or referred for a second time but for a different lesion. (orig.)

  19. Consequences of digital mammography in population-based breast cancer screening: initial changes and long-term impact on referral rates

    Energy Technology Data Exchange (ETDEWEB)

    Bluekens, Adriana M.J. [National Expert and Training Centre for Breast Cancer Screening, Nijmegen (Netherlands); St. Elisabeth Hospital, Department of Radiology, Tilburg (Netherlands); Karssemeijer, Nico [Radboud University Nijmegen Medical Centre, Department of Radiology, Nijmegen (Netherlands); Beijerinck, David; Deurenberg, Jan J.M. [Preventicon Screening Centre/Mid-West, Utrecht (Netherlands); Engen, Ruben E. van [National Expert and Training Centre for Breast Cancer Screening, Nijmegen (Netherlands); Broeders, Mireille J.M. [National Expert and Training Centre for Breast Cancer Screening, Nijmegen (Netherlands); Radboud University Nijmegen Medical Centre, Department of Epidemiology, Biostatistics and HTA, Nijmegen (Netherlands); Heeten, Gerard J. den [National Expert and Training Centre for Breast Cancer Screening, Nijmegen (Netherlands); Academic Medical Centre (AMC), Department of Radiology, Amsterdam (Netherlands)

    2010-09-15

    To investigate the referral pattern after the transition to full-field digital mammography (FFDM) in a population-based breast cancer screening programme. Preceding the nationwide digitalisation of the Dutch screening programme, an FFDM feasibility study was conducted. Detection and referral rates for FFDM and screen-film mammography (SFM) were compared for first and subsequent screens. Furthermore, radiological characteristics of referrals in digital screening were assessed. A total of 312,414 screening mammograms were performed (43,913 digital and 268,501 conventional), with 4,473 consecutive referrals (966 following FFDM). Initially the FFDM referral rate peaked, and many false-positive results were noted as a consequence of pseudolesions and increased detection of (benign) microcalcifications. A higher overall referral rate was observed in FFDM screening in both first and subsequent examinations (p <.001), with a significant increase in cancer detection (p =.010). As a result of initial inexperience with digital screening images implementing FFDM in a population-based breast cancer screening programme may lead to a strong, but temporary increase in referral. Dedicated training in digital screening for radiographers and screening radiologists is therefore recommended. Referral rates decrease and stabilise (learning curve effect) at a higher level than in conventional screening, yet with significantly enhanced cancer detection. (orig.)

  20. Consequences of digital mammography in population-based breast cancer screening: initial changes and long-term impact on referral rates.

    Science.gov (United States)

    Bluekens, Adriana M J; Karssemeijer, Nico; Beijerinck, David; Deurenberg, Jan J M; van Engen, Ruben E; Broeders, Mireille J M; den Heeten, Gerard J

    2010-09-01

    To investigate the referral pattern after the transition to full-field digital mammography (FFDM) in a population-based breast cancer screening programme. Preceding the nationwide digitalisation of the Dutch screening programme, an FFDM feasibility study was conducted. Detection and referral rates for FFDM and screen-film mammography (SFM) were compared for first and subsequent screens. Furthermore, radiological characteristics of referrals in digital screening were assessed. A total of 312,414 screening mammograms were performed (43,913 digital and 268,501 conventional), with 4,473 consecutive referrals (966 following FFDM). Initially the FFDM referral rate peaked, and many false-positive results were noted as a consequence of pseudolesions and increased detection of (benign) microcalcifications. A higher overall referral rate was observed in FFDM screening in both first and subsequent examinations (p < .001), with a significant increase in cancer detection (p = .010). As a result of initial inexperience with digital screening images implementing FFDM in a population-based breast cancer screening programme may lead to a strong, but temporary increase in referral. Dedicated training in digital screening for radiographers and screening radiologists is therefore recommended. Referral rates decrease and stabilise (learning curve effect) at a higher level than in conventional screening, yet with significantly enhanced cancer detection.

  1. Consequences of digital mammography in population-based breast cancer screening: initial changes and long-term impact on referral rates

    International Nuclear Information System (INIS)

    Bluekens, Adriana M.J.; Karssemeijer, Nico; Beijerinck, David; Deurenberg, Jan J.M.; Engen, Ruben E. van; Broeders, Mireille J.M.; Heeten, Gerard J. den

    2010-01-01

    To investigate the referral pattern after the transition to full-field digital mammography (FFDM) in a population-based breast cancer screening programme. Preceding the nationwide digitalisation of the Dutch screening programme, an FFDM feasibility study was conducted. Detection and referral rates for FFDM and screen-film mammography (SFM) were compared for first and subsequent screens. Furthermore, radiological characteristics of referrals in digital screening were assessed. A total of 312,414 screening mammograms were performed (43,913 digital and 268,501 conventional), with 4,473 consecutive referrals (966 following FFDM). Initially the FFDM referral rate peaked, and many false-positive results were noted as a consequence of pseudolesions and increased detection of (benign) microcalcifications. A higher overall referral rate was observed in FFDM screening in both first and subsequent examinations (p <.001), with a significant increase in cancer detection (p =.010). As a result of initial inexperience with digital screening images implementing FFDM in a population-based breast cancer screening programme may lead to a strong, but temporary increase in referral. Dedicated training in digital screening for radiographers and screening radiologists is therefore recommended. Referral rates decrease and stabilise (learning curve effect) at a higher level than in conventional screening, yet with significantly enhanced cancer detection. (orig.)

  2. Initial Image Quality and Clinical Experience with New CR Digital Mammography System: A Phantom and Clinical Study

    International Nuclear Information System (INIS)

    Gaona, Enrique; Enriquez, Jesus Gabriel Franco; Alfonso, Beatriz Y. Alvarez; Castellanos, Gustavo Casian

    2008-01-01

    The goal of the study was to evaluate the first CR digital mammography system ( registered Konica-Minolta) in Mexico in clinical routine for cancer detection in a screening population and to determine if high resolution CR digital imaging is equivalent to state-of-the-art screen-film imaging. The mammograms were evaluated by two observers with cytological or histological confirmation for BIRADS 3, 4 and 5. Contrast, exposure and artifacts of the images were evaluated. Different details like skin, retromamillary space and parenchymal structures were judged. The detectability of microcalcifications and lesions were compared and correlated to histology. The difference in sensitivity of CR Mammography (CRM) and Screen Film Mammography (SFM) was not statistically significant. However, CRM had a significantly lower recall rate, and the lesion detection was equal or superior to conventional images. There is no significant difference in the number of microcalcifications and highly suspicious calcifications were equally detected on both film-screen and digital images. Different anatomical regions were better detectable in digital than in conventional mammography

  3. Screening mammography in Finland--1.5 million examinations with 97 percent specificity

    International Nuclear Information System (INIS)

    Dean, P.B.; Pamilo, M.

    1999-01-01

    A nationwide mammography screening program including women aged 50-59 years at the time of the first invitation and involving more than 100 radiologists was started in Finland in January, 1987. From 1987 through 1997, a total of 1,690,496 invitations to biennial two-view mammography screening was sent out. The compliance for screening was 88.5% with 1,495,744 screening examinations performed during this 11-year period. There were 49,020 recalls for further work-up studies and 9,689 women were referred for surgery. The total number of screening-detected breast cancers was 5,595, giving a detection rate of 3.7 cancers per 1000 screening studies. More than half of all surgical biopsies revealed breast cancer and 67.8% of the invasive cancers were at Stage I. The positive predictive value of referral to surgical biopsy increased from 33.2% in 1987 to 65.5% in 1997. and the ratio of malignant to benign biopsies more than tripled from the first to the fifth year of screening. The observed/expected ratio of invasive cancer detection was 2.44. Only 0.27% of all screening mammograms were followed by a benign biopsy, and 2.90% of all screening mammograms were followed by the women being recalled for further studies and not found to have breast cancer. This gave a specificity of recall after screening mammography greater than 97.0% and a specificity of referral to surgical biopsy greater than 99.7%. Measures of specificity improved considerably during the first three years of the screening program. The high specificity of screening mammography can be attributed to the nature of the screening process as well as to the opportunity for individual radiologists to attain a greater level of experience and competence. The decision to recall appears to have been crucial in determining the specificity

  4. Volumetric breast density affects performance of digital screening mammography

    OpenAIRE

    Wanders, JO; Holland, K; Veldhuis, WB; Mann, RM; Pijnappel, RM; Peeters, PH; Van Gils, CH; Karssemeijer, N

    2016-01-01

    PURPOSE: To determine to what extent automatically measured volumetric mammographic density influences screening performance when using digital mammography (DM). METHODS: We collected a consecutive series of 111,898 DM examinations (2003-2011) from one screening unit of the Dutch biennial screening program (age 50-75 years). Volumetric mammographic density was automatically assessed using Volpara. We determined screening performance measures for four density categories comparable to the Ameri...

  5. A clinical trial of a rare earth screen/film system in a periapical cassette

    International Nuclear Information System (INIS)

    Kogon, S.L.; Stephens, R.G.; Reid, J.A.; Lubus, N.J.

    1984-01-01

    In a clinical trial, a slow rare earth screen/film system (Siemens Titan 2D/Kodak XG) was used to obtain intraoral radiographs at conventional monitoring stages in endodontic treatment. The screen film image proved to be an effective substitute for the direct-exposure Ultraspeed periapical film. The intraoral cassettes, designed and fabricated for the study, were an adaptation of the flexible, vacuum-sealed cassettes used in mammography. It is believed that when a practicable periapical cassette is manufactured, many additional indications for the system are probable. Major reductions in patient exposure of at least 85% to 90% per periapical film would be effected

  6. An adaptive algorithm for the detection of microcalcifications in simulated low-dose mammography

    Science.gov (United States)

    Treiber, O.; Wanninger, F.; Führ, H.; Panzer, W.; Regulla, D.; Winkler, G.

    2003-02-01

    This paper uses the task of microcalcification detection as a benchmark problem to assess the potential for dose reduction in x-ray mammography. We present the results of a newly developed algorithm for detection of microcalcifications as a case study for a typical commercial film-screen system (Kodak Min-R 2000/2190). The first part of the paper deals with the simulation of dose reduction for film-screen mammography based on a physical model of the imaging process. Use of a more sensitive film-screen system is expected to result in additional smoothing of the image. We introduce two different models of that behaviour, called moderate and strong smoothing. We then present an adaptive, model-based microcalcification detection algorithm. Comparing detection results with ground-truth images obtained under the supervision of an expert radiologist allows us to establish the soundness of the detection algorithm. We measure the performance on the dose-reduced images in order to assess the loss of information due to dose reduction. It turns out that the smoothing behaviour has a strong influence on detection rates. For moderate smoothing, a dose reduction by 25% has no serious influence on the detection results, whereas a dose reduction by 50% already entails a marked deterioration of the performance. Strong smoothing generally leads to an unacceptable loss of image quality. The test results emphasize the impact of the more sensitive film-screen system and its characteristics on the problem of assessing the potential for dose reduction in film-screen mammography. The general approach presented in the paper can be adapted to fully digital mammography.

  7. An adaptive algorithm for the detection of microcalcifications in simulated low-dose mammography

    International Nuclear Information System (INIS)

    Treiber, O; Wanninger, F; Fuehr, H; Panzer, W; Regulla, D; Winkler, G

    2003-01-01

    This paper uses the task of microcalcification detection as a benchmark problem to assess the potential for dose reduction in x-ray mammography. We present the results of a newly developed algorithm for detection of microcalcifications as a case study for a typical commercial film-screen system (Kodak Min-R 2000/2190). The first part of the paper deals with the simulation of dose reduction for film-screen mammography based on a physical model of the imaging process. Use of a more sensitive film-screen system is expected to result in additional smoothing of the image. We introduce two different models of that behaviour, called moderate and strong smoothing. We then present an adaptive, model-based microcalcification detection algorithm. Comparing detection results with ground-truth images obtained under the supervision of an expert radiologist allows us to establish the soundness of the detection algorithm. We measure the performance on the dose-reduced images in order to assess the loss of information due to dose reduction. It turns out that the smoothing behaviour has a strong influence on detection rates. For moderate smoothing, a dose reduction by 25% has no serious influence on the detection results, whereas a dose reduction by 50% already entails a marked deterioration of the performance. Strong smoothing generally leads to an unacceptable loss of image quality. The test results emphasize the impact of the more sensitive film-screen system and its characteristics on the problem of assessing the potential for dose reduction in film-screen mammography. The general approach presented in the paper can be adapted to fully digital mammography

  8. Transformative learning theory: facilitating mammography screening in rural women.

    Science.gov (United States)

    Purtzer, Mary Anne; Overstreet, Lindsey

    2014-03-01

    To use transformative learning to investigate what experiences serve as catalysts for mammography screening, the cognitive and affective responses that result from the catalyst, and how screening behavior is impacted. A descriptive qualitative study. Southeastern Wyoming. 25 low-income, rural women aged 40 years and older. Four focus group interviews. Cancer experiences triggered universal responses of fear by screeners and nonscreeners. The manner in which that fear response was interpreted was a critical factor in the facilitation of, or impedance to, screening. Dichotomous interpretations of fear responses provided the context for screening behavior. Immobilizing and isolating experiences were associated with nonscreening behavior, whereas motivation and self-efficacy were associated with screening behavior. Transformative learning theory is a useful framework from which to explain differences in mammography screening behavior. Creating opportunities that facilitate dialogue and critical reflection hold the potential to change immobilizing and isolating frames of reference in nonscreening women. To help women transcend their fear and become self-efficacious, nurses can assess how cancer and the screening experience is viewed and, if indicated, move beyond standard education and offer opportunities for dialogue and critical reflection.

  9. Breast cancer mortality in organised mammography screening in Denmark: comparative study

    DEFF Research Database (Denmark)

    Juhl Jørgensen, Karsten; Zahl, Per-Henrik; Gøtzsche, Peter C

    2010-01-01

    To determine whether the previously observed 25% reduction in breast cancer mortality in Copenhagen following the introduction of mammography screening was indeed due to screening, by using an additional screening region and five years additional follow-up....

  10. Factors contributing to low participation in mammography screening in Papua New Guinea

    International Nuclear Information System (INIS)

    Pape, R.; Spuur, K.M.; Umo, P.

    2016-01-01

    Aim: The aim of this paper is to describe the current state of mammography screening services in Papua New Guinea (PNG) and to document factors thought to contribute to low participation in the free mammography screening service at the Pacific International Hospital (PIH), Port Moresby. Method: Women attending for mammography screening at PIH between August 2006 and July 2010 were invited to complete a survey investigating environmental, political, social, financial, cultural and health factors thought to be contributing to low participation in the mammography screening service. Ethics approval and permission to collect data was granted through the University of Papua New Guinea, School of Medicine and Health Sciences Research and Ethics Committee and by the Medical Director and Chief Operating Officer of PIH. Results: The reasons for low participation were found to be multifactorial; difficult environmental factors 42.86%; financial dependency factors 40.54%; cultural factors related to exposing the body 50.03%, social factors (sexual harassment) 77.6%, political factors 4.29% and health factors including poor health 54.54%. Conclusion: The study demonstrated that in this snapshot of PNG women, the low participation rate in the free mammography screening program at PIH was influenced by various interrelated factors inherent in both the PNG environment and culture, in particular lack of transport infrastructure, financial burden and sexual harassment. As low participation directly impacts upon the high breast cancer mortality in PNG women, a more comprehensive study of the women of PNG is required to validate this research. - Highlights: • Snap shot of issues surrounding low participation in the free screening program. • Geography and poor transport infrastructure made participation almost impossible. • Lack of funds for transport by either road or air deterred participation. • Sexual harassment was the main social factor that deterred access.

  11. Radiation-Induced Breast Cancer Incidence and Mortality From Digital Mammography Screening: A Modeling Study.

    Science.gov (United States)

    Miglioretti, Diana L; Lange, Jane; van den Broek, Jeroen J; Lee, Christoph I; van Ravesteyn, Nicolien T; Ritley, Dominique; Kerlikowske, Karla; Fenton, Joshua J; Melnikow, Joy; de Koning, Harry J; Hubbard, Rebecca A

    2016-02-16

    Estimates of risk for radiation-induced breast cancer from mammography screening have not considered variation in dose exposure or diagnostic work-up after abnormal screening results. To estimate distributions of radiation-induced breast cancer incidence and mortality from digital mammography screening while considering exposure from screening and diagnostic mammography and dose variation among women. 2 simulation-modeling approaches. U.S. population. Women aged 40 to 74 years. Annual or biennial digital mammography screening from age 40, 45, or 50 years until age 74 years. Lifetime breast cancer deaths averted (benefits) and radiation-induced breast cancer incidence and mortality (harms) per 100,000 women screened. Annual screening of 100,000 women aged 40 to 74 years was projected to induce 125 breast cancer cases (95% CI, 88 to 178) leading to 16 deaths (CI, 11 to 23), relative to 968 breast cancer deaths averted by early detection from screening. Women exposed at the 95th percentile were projected to develop 246 cases of radiation-induced breast cancer leading to 32 deaths per 100,000 women. Women with large breasts requiring extra views for complete examination (8% of population) were projected to have greater radiation-induced breast cancer risk (266 cancer cases and 35 deaths per 100,000 women) than other women (113 cancer cases and 15 deaths per 100,000 women). Biennial screening starting at age 50 years reduced risk for radiation-induced cancer 5-fold. Life-years lost from radiation-induced breast cancer could not be estimated. Radiation-induced breast cancer incidence and mortality from digital mammography screening are affected by dose variability from screening, resultant diagnostic work-up, initiation age, and screening frequency. Women with large breasts may have a greater risk for radiation-induced breast cancer. Agency for Healthcare Research and Quality, U.S. Preventive Services Task Force, National Cancer Institute.

  12. Participation rate or informed choice? Rethinking the European key performance indicators for mammography screening.

    Science.gov (United States)

    Strech, Daniel

    2014-03-01

    Despite the intensive controversies about the likelihood of benefits and harms of mammography screening almost all experts conclude that the choice to screen or not to screen needs to be made by the individual patient who is adequately informed. However, the "European guideline for quality assurance in breast cancer screening and diagnosis" specifies a participation rate of 70% as the key performance indicator for mammography screening. This paper argues that neither the existing evidence on benefits and harms, nor survey research with women, nor compliance rates in clinical trials, nor cost-effectiveness ratios justify participation rates as a reasonable performance indicator for preference-sensitive condition such as mammography screening. In contrast, an informed choice rate would be more reasonable. Further research needs to address the practical challenges in assessing informed choice rates. Copyright © 2013 Elsevier Ireland Ltd. All rights reserved.

  13. Radiographic techniques for digital mammography

    International Nuclear Information System (INIS)

    Horita, Katsuhei

    2007-01-01

    Since the differences in X-ray absorption between various breast tissues are small, a dedicated X-ray system for examination of the breast and a high-contrast, high-resolution screen/film system (SFM) (light-receiving system) are employed for X-ray diagnosis. Currently, however, there is a strong trend toward digital imaging in the field of general radiography, and this trend is also reflected in the field of mammographic examination. In fact, approximately 70% of facilities purchasing new mammography systems are now selecting a digital mammography system (DRM). Given this situation, this report reviews the differences between SFM and DRM and discusses the radiographic techniques and quality assurance procedures for digital mammography. (author)

  14. Contrast-enhanced spectral mammography in patients referred from the breast cancer screening programme

    Energy Technology Data Exchange (ETDEWEB)

    Lobbes, Marc B.I.; Wildberger, Joachim E. [Maastricht University Medical Center, Department of Radiology, Maastricht (Netherlands); GROW School for Oncology and Developmental Biology, Maastricht (Netherlands); Lalji, Ulrich; Houwers, Janneke; Nijssen, Estelle C. [Maastricht University Medical Center, Department of Radiology, Maastricht (Netherlands); Nelemans, Patty J. [Maastricht University, Department of Epidemiology, Maastricht (Netherlands); Roozendaal, Lori van; Heuts, Esther [Maastricht University Medical Center, Department of Surgical Oncology, Maastricht (Netherlands); Smidt, Marjolein L. [Maastricht University Medical Center, Department of Surgical Oncology, Maastricht (Netherlands); GROW School for Oncology and Developmental Biology, Maastricht (Netherlands)

    2014-07-15

    Feasibility studies have shown that contrast-enhanced spectral mammography (CESM) increases diagnostic accuracy of mammography. We studied diagnostic accuracy of CESM in patients referred from the breast cancer screening programme, who have a lower disease prevalence than previously published papers on CESM. During 6 months, all women referred to our hospital were eligible for CESM. Two radiologists blinded to the final diagnosis provided BI-RADS classifications for conventional mammography and CESM. Statistical significance of differences between mammography and CESM was calculated using McNemar's test. Receiver operating characteristic (ROC) curves were constructed for both imaging modalities. Of the 116 eligible women, 113 underwent CESM. CESM increased sensitivity to 100.0 % (+3.1 %), specificity to 87.7 % (+45.7 %), PPV to 76.2 % (+36.5 %) and NPV to 100.0 % (+2.9 %) as compared to mammography. Differences between conventional mammography and CESM were statistically significant (p < 0.0001). A similar trend was observed in the ROC curve. For conventional mammography, AUC was 0.779. With CESM, AUC increased to 0.976 (p < 0.0001). In addition, good agreement between tumour diameters measured using CESM, breast MRI and histopathology was observed. CESM increases diagnostic performance of conventional mammography, even in lower prevalence patient populations such as referrals from breast cancer screening. (orig.)

  15. Contrast-enhanced spectral mammography in patients referred from the breast cancer screening programme

    International Nuclear Information System (INIS)

    Lobbes, Marc B.I.; Wildberger, Joachim E.; Lalji, Ulrich; Houwers, Janneke; Nijssen, Estelle C.; Nelemans, Patty J.; Roozendaal, Lori van; Heuts, Esther; Smidt, Marjolein L.

    2014-01-01

    Feasibility studies have shown that contrast-enhanced spectral mammography (CESM) increases diagnostic accuracy of mammography. We studied diagnostic accuracy of CESM in patients referred from the breast cancer screening programme, who have a lower disease prevalence than previously published papers on CESM. During 6 months, all women referred to our hospital were eligible for CESM. Two radiologists blinded to the final diagnosis provided BI-RADS classifications for conventional mammography and CESM. Statistical significance of differences between mammography and CESM was calculated using McNemar's test. Receiver operating characteristic (ROC) curves were constructed for both imaging modalities. Of the 116 eligible women, 113 underwent CESM. CESM increased sensitivity to 100.0 % (+3.1 %), specificity to 87.7 % (+45.7 %), PPV to 76.2 % (+36.5 %) and NPV to 100.0 % (+2.9 %) as compared to mammography. Differences between conventional mammography and CESM were statistically significant (p < 0.0001). A similar trend was observed in the ROC curve. For conventional mammography, AUC was 0.779. With CESM, AUC increased to 0.976 (p < 0.0001). In addition, good agreement between tumour diameters measured using CESM, breast MRI and histopathology was observed. CESM increases diagnostic performance of conventional mammography, even in lower prevalence patient populations such as referrals from breast cancer screening. (orig.)

  16. Radiology Residents' Performance in Screening Mammography Interpretation

    International Nuclear Information System (INIS)

    Lee, Eun Hye; Lyou, Chae Yeon

    2013-01-01

    To evaluate radiology residents' performance in screening mammography interpretation and to analyze the factors affecting performance. We enrolled 203 residents from 21 institutions and performed mammography interpretation tests. Between the trainee and non-trainee groups, we compared the interpretation score, recall rate, sensitivity, positive predictive value (PPV) and false-positive rate (FPR). We estimated the training effect using the score differences between trainee and non-trainee groups. We analyzed the factors affecting performance between training-effective and non-effective groups. Trainees were superior to non-trainees regarding interpretation score (43.1 vs. 37.1), recall rate (11.0 vs. 15.5%), sensitivity (83.6 vs. 72.0%), PPV (53.0 vs. 32.4%) and FPR (13.5 vs. 25.5). The longer the training period, the better were the interpretation score, recall rate, sensitivity, PPV and FPR (rho = 0.486, -0.375, 0.343, 0.504, -0.446, respectively). The training affected an increase by an average of 6 points; however, 31.6% of institutions showed no effect. A difference was noted in the volume of mammography interpretation during a month (594.0 vs. 476.9) and dedication of breast staff (61.5 vs. 0%) between training-effective and non-effective groups. Trainees showed better performance in mammography interpretation compared to non-trainees. Moreover, performance was correlated with the training period. The factors affecting performance were the volume of mammography interpretation and the dedication of the breast staff.

  17. Mammography and Pap test screening among low-income foreign-born Hispanic women in the USA

    Directory of Open Access Journals (Sweden)

    Fernandez Maria E.

    1998-01-01

    Full Text Available Little is known about the factors influencing screening among low-income Hispanic women particularly among recent immigrants. A sample of 148 low-income, low-literate, foreign-born Hispanic women residing in the Washington DC metropolitan area participated in the study. The mean age of the sample was 46.2 (SD = 11.5, 84% reported annual household incomes<=$15,000. All women were Spanish speakers and had low acculturation levels. Ninety six percent had reported having a Pap smear, but 24% were not in compliance with recommended screening (Pap test within the last 3 years. Among women 40 and older, 62% had received a mammogram, but only 33% were compliant with age appropriate recommended mammography screening guidelines. Women in this study had more misconceptions about cancer than Hispanics in other studies. Multivariate logistic models for correlates of Pap test and mammography screening behavior indicate that factors such as fear of the screening test, embarrassment, and lack of knowledge influenced screening behavior. In conclusion, women in this study had lower rates of mammography screening than non-Hispanic women and lower rates of compliance with recommended Mammography and Pap test screening guidelines.

  18. Screening mammography in women 65 years old and older

    International Nuclear Information System (INIS)

    Rubin, E.; Mulligan, S.A.; Han, S.Y.; Bernreuter, W.K.; Stanley, R.J.

    1990-01-01

    This paper compares the results of mammographic screening in women aged 65 years and older to those of women aged 50--64 years, to define risk factors and prior use of mammography in these women, and to determine whether mammographic abnormalities are managed differently in the two age groups. Historical data, mammographic findings, and biopsy results were analyzed for all women over 50 years of age screened during 1988 (2,862 patients) at a university hospital-based outpatient center and mobile van, excluding those referred by oncologists. The following factors were determined for patients screened at the outpatient center and the mobile van, with both groups divided according to patient age (50--64 vs ≥ 65 years): presence of risk factors, previous biopsy, exogenous hormones, percentage of black patients, previous mammography, biopsy rate, cancer detection rate, positive nodes, and presence of tumors smaller than 1 cm or ductal carcinoma in-situ

  19. Mammography screening in Nigeria – A critical comparison to other countries

    International Nuclear Information System (INIS)

    Lawal, O.; Murphy, F.J.; Hogg, P.; Irurhe, N.; Nightingale, J.

    2015-01-01

    Breast cancer is a leading cause of death among women, and according to the World Health Organisation (WHO) there will be a significant increase in the incidence of breast cancer in developing countries such as Nigeria by 2030. However, mammography screening can significantly reduce the mortality and morbidity of women as a result of breast cancer. Therefore, the aim of this review is to evaluate the mammography screening program in Nigeria, compare it with four developed countries and then draw inferences. The Nigerian screening program was evaluated using the following factors: - mode of invitation, frequency of screening, age of the participants, image projections, imaging staff, quality assurance program, and availability. Similarities exist between Nigeria and four developed countries (the United States of America, United Kingdom, Australia and Canada), for instance trained Radiographers do the imaging and the image projections obtained are the same. However, important differences exist, these include mode of invitation, financial model, quality assurance program and availability. On comparison with the four developed countries, various issues have been identified within the Nigerian breast screening programmes. No one simple solution can be offered to address these as the challenges are multi-factorial. - Highlights: • The mammography screening program in Nigeria is compared to four structured screening programs. • There is poor participation of Nigerian women in the screening program. • The cost of mammogram is associated with poor attendance. • The Nigerian screening program lags behind with the age of women invited for screening and lack of quality assurance program.

  20. Soft copy digital mammography

    International Nuclear Information System (INIS)

    Kim, Hak Hee

    2005-01-01

    Screen-film mammography (SFM) has been the standard method used for breast cancer screening and making a clinical diagnosis. It is a valuable modality for the detection and differentiation of breast calcifications. The advantages are the high spatital resolution, the convenient display, and inexpensiveness. However, it has some inherent limitations such as its low detective quantum efficiency and difficulty of post-processing after obtaining after an image. Digital mammography (DM) has the potential to overcome the inherent limitations of SFM. DM systems directly qualify x-ray photons and decouple the process of x-ray photon detection from the image display. The digital images can be processed by a computer and displayed in multiple formats. Thus, DM is better than SFM for the detection of mass lesions due to its high contrast resolution

  1. Effect of age on breast cancer screening using tomosynthesis in combination with digital mammography.

    Science.gov (United States)

    Rafferty, Elizabeth A; Rose, Stephen L; Miller, Dave P; Durand, Melissa A; Conant, Emily F; Copit, Debra S; Friedewald, Sarah M; Plecha, Donna M; Ott, Ingrid L; Hayes, Mary K; Carlson, Kara L; Cink, Thomas M; Barke, Lora D; Greer, Linda N; Niklason, Loren T

    2017-08-01

    To determine the effect of tomosynthesis imaging as a function of age for breast cancer screening. Screening performance metrics from 13 institutions were examined for 12 months prior to introduction of tomosynthesis (period 1) and compared to those after introduction of tomosynthesis (period 2, range 3-22 months). Screening metrics for women ages 40-49, 50-59, 60-69, and 70+ , included rates per 1000 screens for recalls, biopsies, cancers, and invasive cancers detected. Performance parameters were compared for women screened with digital mammography alone (n = 278,908) and digital mammography + tomosynthesis (n = 173,414). Addition of tomosynthesis to digital mammography produced significant reductions in recall rates for all age groups and significant increases in cancer detection rates for women 40-69. Largest recall rate reduction with tomosynthesis was for women 40-49, decreasing from 137 (95% CI 117-156) to 115 (95% CI 95-135); difference, -22 (95% CI -26 to -18; P cancer detection rate for women 40-49 from 1.6 (95% CI 1.2-1.9) to 2.7 (95% CI 2.2-3.1) with tomosynthesis (difference, 1.1; 95% CI 0.6-1.6; P cancer detection rates for women 40-69 and decreased recall rates for all age groups with largest performance gains seen in women 40-49. The similar performance seen with tomosynthesis screening for women in their 40s compared to digital mammography for women in their 50s argues strongly for commencement of mammography screening at age 40 using tomosynthesis.

  2. Quality control of physician-performed mammography. Importance of original attempts to improve quality

    International Nuclear Information System (INIS)

    Nakayama, Takashi; Terada, Hiroshi; Kotsuma, Yoshikazu

    2006-01-01

    In order to perform effective breast cancer screening with mammography, family doctors should be encouraged to participate. At institutions without specific radiology technicians, physicians themselves are required to perform mammography and operate the equipment, otherwise it is difficult to consistently obtain good-quality mammograms. Our institutions have been given a grade ''A'' evaluation by the Central Committee for Quality Control of Mammographic Screening (CCQCMS), due largely to our own efforts and promotion. Here we report our experience in solving a number of problems that occurred during the establishment of our system. We used the SEPIO standard mammography apparatus with a MD-100/CM-H screen/filter system, and developed films using a TCX-202 automatic film processor. Problems due to asymmetry of the bilateral breasts and lack of retroglandular fat tissue space and inframammary folds seen on our initial mammograms were overcome by placing marks at the postion of the AEC sensor, and at both ends and the center of the film on a bucky table. We simplified the markers by removing several complicated ones. We tried to rectify areas of the image that were obscured due to the difference in size between the inside of the cassette and the screen. Physicians and a radiology technician attended a mammography study course once weekly, and attempted to improve the quality of mammograms and our reading ability by obtaining advice from members of the CCQCMS. Manufacturers responded with considerable delay to our attempt to overcome the troublesome appearance of numerous microcalfication-like artifact shadows caused by screens. In conclusion, in order to perform effective breast cancer screening with mammography, we must obtain mammograms of good quality, for which it is necessary to always try to seek new ways of improving. At the same time, manufacturers need to respond quickly to queries and problems related to quality control. (author)

  3. Radiation dose in mammography: an energy-balance approach

    International Nuclear Information System (INIS)

    Shrivastava, P.N.

    1981-01-01

    An energy-balance approach for calculation of mean, integral, and midpoint doses in mammography is introduced. Estimation of mean absorbed dose for individual applications is described. Calculations made for a range of xeromammographic techniques used at various breast cancer detection centers show that although increasing the beam h.v.l. dramatically decreases breast surface exposure, it is insignificant in lowering mean breast dose or radiation risk. Thus selection of a moderate h.v.l. to optimize image quality in xeromammography may be more beneficial than unduly increasing h.v.l. merely to reduce surface exposure. The mean breast dose per mammogram with low h.v.l. screen-film techniques was 3 to 9 times lower than for xeromammography, suggesting that general acceptance of screen-film techniques can significantly reduce the risk associated with mammography

  4. Mammography: an update of the EUSOBI recommendations on information for women.

    Science.gov (United States)

    Sardanelli, Francesco; Fallenberg, Eva M; Clauser, Paola; Trimboli, Rubina M; Camps-Herrero, Julia; Helbich, Thomas H; Forrai, Gabor

    2017-02-01

    This article summarises the information to be offered to women about mammography. After a delineation of the aim of early diagnosis of breast cancer, the difference between screening mammography and diagnostic mammography is explained. The need to bring images and reports from the previous mammogram (and from other recent breast imaging examinations) is highlighted. Mammography technique and procedure are described with particular attention to discomfort and pain experienced by a small number of women who undergo the test. Information is given on the recall during a screening programme and on the request for further work-up after a diagnostic mammography. The logic of the mammography report and of classification systems such as R1-R5 and BI-RADS is illustrated, and brief but clear information is given about the diagnostic performance of the test, with particular reference to interval cancers, i.e., those cancers that are missed at screening mammography. Moreover, the breast cancer risk due to radiation exposure from mammography is compared to the reduction in mortality obtained with the test, and the concept of overdiagnosis is presented with a reliable estimation of its extent. Information about new mammographic technologies (tomosynthesis and contrast-enhanced spectral mammography) is also given. Finally, frequently asked questions are answered. • Direct digital mammography should be preferred to film-screen or phosphor plates. • Screening (in asymptomatic women) should be distinguished from diagnosis (in symptomatic women). • A breast symptom has to be considered even after a negative mammogram. • Digital breast tomosynthesis increases cancer detection and decreases the recall rate. • Contrast-enhanced spectral mammography can help in cancer detection and lesion characterisation.

  5. XERG-mammography system: a solution to the dose-quality problem

    Energy Technology Data Exchange (ETDEWEB)

    Friedrich, M

    1981-05-01

    The XERG (Xonics-Electron-Radio-Graphy) system is the first ionographic system (High-Pressure-Gas-Iono-graphy) suitable for clinical application which became available for testing. The basic principle, the function and imaging qualities of the XERG system are described and first clinical experiences reported. The XERG mammogram is a transparent X-ray negative image, the image quality of which is characterized by good general image contrast, a moderate edge-effect and a high quantum-noise level but giving an extremely low dose rate (4.5% compared to screenless mammography film). Although the XERG quality is not satisfactory in contact technique, it yields results which are equal in quality, when using a 1.5-fold magnification technique, to the results obtained with screenless film mammography at one-tenth of the dose, and is superior to any commercially available film-screen system. Hence, in our opinion, the XERG mammography system is a step forward towards high-quality low-dose mammography.

  6. X-ray phase imaging using a X-ray tube with a small focal spot. Improvement of image quality in mammography

    International Nuclear Information System (INIS)

    Honda, Chika; Ohara, Hiromu; Ishisaka, Akira; Shimada, Fumio

    2002-01-01

    Phase contrast X-ray imaging has been studied intensively using X-rays from synchrotron radiation and micro-focus X-ray tubes. However, these studies have revealed the difficulty of this technique's application to practical medical imaging. We have created a phase contrast imaging technique using a molybdenum X-ray tube with a small focal spot size for mammography. We identified the radiographic conditions in phase contrast magnification mammography with a screen-film system, where edge effect due to phase contrast overcomes geometrical unsharpness caused by the 0.1 mm-focal spot of a molybdenum X-ray tube. The edge enhancement due to phase imaging was observed in an image of a plastic tube, and then geometrical configuration of the X-ray tube, the object and the screen-film system was determined for phase imaging of mammography. In order to investigate a potential for medical application of this method, we conducted evaluation of the images of the American Collage of Radiology (ACR) 156 mammography phantom. We obtained higher scores for phase imaging using high speed screen-film systems without any increase of X-ray dose than the score for contract imaging using a standard speed screen-film system. (author)

  7. Cost-effectiveness of breast cancer screening using mammography in Vietnamese women

    Science.gov (United States)

    2018-01-01

    Background The incidence rate of breast cancer is increasing and has become the most common cancer in Vietnamese women while the survival rate is lower than that of developed countries. Early detection to improve breast cancer survival as well as reducing risk factors remains the cornerstone of breast cancer control according to the World Health Organization (WHO). This study aims to evaluate the costs and outcomes of introducing a mammography screening program for Vietnamese women aged 45–64 years, compared to the current situation of no screening. Methods Decision analytical modeling using Markov chain analysis was used to estimate costs and health outcomes over a lifetime horizon. Model inputs were derived from published literature and the results were reported as incremental cost-effectiveness ratios (ICERs) and/or incremental net monetary benefits (INMBs). One-way sensitivity analyses and probabilistic sensitivity analyses were performed to assess parameter uncertainty. Results The ICER per life year gained of the first round of mammography screening was US$3647.06 and US$4405.44 for women aged 50–54 years and 55–59 years, respectively. In probabilistic sensitivity analyses, mammography screening in the 50–54 age group and the 55–59 age group were cost-effective in 100% of cases at a threshold of three times the Vietnamese Gross Domestic Product (GDP) i.e., US$6332.70. However, less than 50% of the cases in the 60–64 age group and 0% of the cases in the 45–49 age group were cost effective at the WHO threshold. The ICERs were sensitive to the discount rate, mammography sensitivity, and transition probability from remission to distant recurrence in stage II for all age groups. Conclusion From the healthcare payer viewpoint, offering the first round of mammography screening to Vietnamese women aged 50–59 years should be considered, with the given threshold of three times the Vietnamese GDP per capita. PMID:29579131

  8. Risk-benefit analysis for mass screening of breast cancer utilizing mammography as a screening test

    International Nuclear Information System (INIS)

    Iinuma, T.A.; Tateno, Yukio

    1989-01-01

    Incidence of breast cancers in Japanese women is increasing steadily. Mass screening of breast cancer was started in Japan under auspices of Adult Health Promotion Act of the Japanese Government from 1987. As the first screening method, the palpation of breasts is employed at present, but it is expected to be replaced by the mammography. In this report, the risk-benefit analysis is presented between risk of breast carcinogenesis due to radiation and benefit of mass screening of breast cancer. The benefit of mass screening is taken as the net elongation of average life expectancy of women due to survival from breast cancers. The risk of mammography is taken as the net loss of average life expectancy of women due to breast carcinogenesis. In the latter, the latency time and plateau period of radiation carcinogenesis were taken into consideration in the calculation. The results show that the ages at which the benefit and risk become equal are between 30 and 35 years old when dose equivalent of mammography is between 10 and 20 mSv, that are conventionally used. However, the critical age will be reduced to 20 years old if the dose equivalent becomes 1 mSv. Therefore, it is strongly recommended that a low dose mammographic system should be developed in order to achieve 1 mSv for the mass screening of breast cancer of Japanese women. In author's opinion, this is quite feasible by employing a new digital radiography with imaging plate. (author)

  9. Mathematical simulation for estimating reduction of breast cancer mortality in mass screening using mammography

    International Nuclear Information System (INIS)

    Iinuma, Takeshi; Matsumoto, Tohru; Tateno, Yukio

    1999-01-01

    In Japan it is considered that mammography should be introduced with physical examination for the mass screening of breast cancer instead of physical examination alone, which is performed at present. Before the introduction of mammography, a mathematical simulation should be performed to show the reduction in breast cancer mortality by mass screening compared with an unscreened population. A mathematical model of cancer screening devised by the authors was used to estimate the number of deaths due to breast cancer (A) in the screened group and those (B) in the unscreened group within the same population. Then the relative risk (RR) and attributable risk (RD) were calculated as (A/B) and (B-A) respectively. Three methods of mass screening were compared: (1) physical examination (1-year interval), (2) mammography with physical examination (1-year interval), (3) mammography with physical examination (2-year interval). The calculated RR values were 0.85 for (1), 0.60 for (2) and 0.69 for (3). Assuming that the incidence of breast cancer was 100/10 5 person-years, the calculated RD values were 3.0, 8.1 and 6.2 persons/10 5 person-years for (1), (2) and (3), respectively. The 95% confidence interval of RR for three methods was over 1.0, and thus the reduction of breast cancer mortality was not statistically significant in the present population. In conclusion, mammography with physical examination may reduce breast cancer mortality in comparison with physical examination alone, but a larger number of women must be screened in order to obtain a significant RR value. (author)

  10. Digital breast tomosynthesis versus digital mammography: a clinical performance study

    International Nuclear Information System (INIS)

    Gennaro, Gisella; Baldan, Enrica; Bezzon, Elisabetta; Polico, Ilaria; Proietti, Alessandro; Toffoli, Aida; Toledano, Alicia; Di Maggio, Cosimo; La Grassa, Manuela; Pescarini, Luigi; Muzzio, Pier Carlo

    2010-01-01

    To compare the clinical performance of digital breast tomosynthesis (DBT) with that of full-field digital mammography (FFDM) in a diagnostic population. The study enrolled 200 consenting women who had at least one breast lesion discovered by mammography and/or ultrasound classified as doubtful or suspicious or probably malignant. They underwent tomosynthesis in one view [mediolateral oblique (MLO)] of both breasts at a dose comparable to that of standard screen-film mammography in two views [craniocaudal (CC) and MLO]. Images were rated by six breast radiologists using the BIRADS score. Ratings were compared with the truth established according to the standard of care and a multiple-reader multiple-case (MRMC) receiver-operating characteristic (ROC) analysis was performed. Clinical performance of DBT compared with that of FFDM was evaluated in terms of the difference between areas under ROC curves (AUCs) for BIRADS scores. Overall clinical performance with DBT and FFDM for malignant versus all other cases was not significantly different (AUCs 0.851 vs 0.836, p = 0.645). The lower limit of the 95% CI or the difference between DBT and FFDM AUCs was -4.9%. Clinical performance of tomosynthesis in one view at the same total dose as standard screen-film mammography is not inferior to digital mammography in two views. (orig.)

  11. Cost-effectiveness of annual versus biennial screening mammography for women with high mammographic breast density.

    Science.gov (United States)

    Pataky, Reka; Ismail, Zahra; Coldman, Andrew J; Elwood, Mark; Gelmon, Karen; Hedden, Lindsay; Hislop, Greg; Kan, Lisa; McCoy, Bonnie; Olivotto, Ivo A; Peacock, Stuart

    2014-12-01

    The sensitivity of screening mammography is much lower among women who have dense breast tissue, compared with women who have largely fatty breasts, and they are also at much higher risk of developing the disease. Increasing mammography screening frequency from biennially to annually has been suggested as a policy option to address the elevated risk in this population. The purpose of this study was to assess the cost-effectiveness of annual versus biennial screening mammography among women aged 50-79 with dense breast tissue. A Markov model was constructed based on screening, diagnostic, and treatment pathways for the population-based screening and cancer care programme in British Columbia, Canada. Model probabilities and screening costs were calculated from screening programme data. Costs for breast cancer treatment were calculated from treatment data, and utility values were obtained from the literature. Incremental cost-effectiveness was expressed as cost per quality adjusted life year (QALY), and probabilistic sensitivity analysis was conducted. Compared with biennial screening, annual screening generated an additional 0.0014 QALYs (95% CI: -0.0480-0.0359) at a cost of $819 ($ = Canadian dollars) per patient (95% CI: 506-1185), resulting in an incremental cost effectiveness ratio of $565,912/QALY. Annual screening had a 37.5% probability of being cost-effective at a willingness-to-pay threshold of $100,000/QALY. There is considerable uncertainty about the incremental cost-effectiveness of annual mammography. Further research on the comparative effectiveness of screening strategies for women with high mammographic breast density is warranted, particularly as digital mammography and density measurement become more widespread, before cost-effectiveness can be reevaluated. © The Author(s) 2014 Reprints and permissions: sagepub.co.uk/journalsPermissions.nav.

  12. Breast cancer incidence after the introduction of mammography screening: what should be expected?

    DEFF Research Database (Denmark)

    Svendsen, Anne Louise; Olsen, Anne Helene; von Euler-Chelpin, My

    2006-01-01

    BACKGROUND: A prevalence peak is expected in breast cancer incidence when mammography screening begins, but afterward the incidence still may be elevated compared with prescreening levels. It is important to determine whether this is due to overdiagnosis (ie, the detection of asymptomatic disease...... that would otherwise not have arisen clinically). In the current study, the authors examined breast cancer incidence after the introduction of mammography screening in Denmark. METHODS: Denmark has 2 regional screening programs targeting women ages 50 years to 69 years. The programs were initiated in 1991...

  13. Evaluation of physical parameters and implementation of quality control in mammography diagnosed for a pilot of breast cancer screening in the Caja Costarricense de Seguro Social (CCSS)

    International Nuclear Information System (INIS)

    Hernandez Angulo, Carolina Maria

    2012-01-01

    The purpose of mammography has been to provide the contrast between the lesion and adjacent healthy tissue of the breast. The quality control which should be performed in mammography services is essential to obtain the necessary contrast in mammography and thus achieve a prompt detection of breast lesions. The quality control program has helped to obtain exact diagnosis in mammography and has contributed to reduce mortality from breast cancer in Costa Rica. The Caja Costarricense de Seguro Social (CCSS) has sought to improve the quality of mammograms performed in the different health centers by implementing quality control programs in the services. The evaluation of the physical parameters has had as aim to perform an assessment of the equipment used in mammography facilities. The image quality, dosimetry, optical density, performance, accuracy and repeatability of voltage applied to the tube, filtration and Half-value layer in system of screen film mammography have been evaluated. The usefulness of quality control programs and needs of the services to implement a pilot plan for breast screening, can be seen when comparing the obtained results. The protocol of Mammography Quality Control, TECDOC 1517 from the International Atomic Energy Agency (IAEA), is implemented with this project and the associated software in four of the six hospitals evaluated in this study. (author) [es

  14. Social processes used by African American women in making decisions about mammography screening.

    Science.gov (United States)

    Fowler, Barbara Ann

    2006-01-01

    To describe the social processes used by African American (AA) women ages > or = 50 years in making decisions about mammography screening. Grounded theory methodology. Tape-recorded interviews with a researcher-designed, semi-structured interview guide with an initial and theoretical sample of 30 AA women ages 52 to 71 of diverse socioeconomic status. Interviews occurred in various settings such as the church rectory, women's homes, and work settings. Extensive written field notes and tapes were transcribed verbatim immediately after the interviews by an experienced transcriptionist. The women's decisions about mammography screening were associated with five social processes: (a) acknowledging prior experiences with healthcare providers and systems; (b) reporting fears and fatalistic beliefs of breast cancer and related treatment; (c) valuing the opinions of significant others; (d) relying on religious beliefs and supports; and (e) caregiving responsibilities of significant others. The processes were further differentiated by three distinct decision-making styles: taking charge, enduring, and protesting. Each of the social processes was reported equally and emphasized by the diverse sample of AA women in decisions related to mammography screening. Mammography screening decisions were heavily influenced by caregiving responsibilities. Further research is needed to explain and understand this social process on the health and well-being of AA women over time.

  15. Evaluation of the mammography screening studies conducted in Europe and North America; Auswertung der bisherigen Mammographie-Screening-Studien in Europa und in Nordamerika

    Energy Technology Data Exchange (ETDEWEB)

    Schreer, I. [Mammazentrum des Universitaetsklinikums Kiel (Germany)

    2001-04-01

    The ancient randomized-controlled trials of breast cancer screening have offered clear evidence that invitation to participate in mammography screening with/without clinical examination is effective in breast cancer mortality reduction and underline the detection sensitivity of mammography. Recently published criticism of both the effect and fundamental data handling could be shown to be untenable. Randomized studies underestimate the effect while well-designed observational studies do not systematically overestimate the magnitude of the effect. To transform high-quality study results in all-day's practice is a huge challenge, but affordable as has been demonstrated in Great Britain, the Netherlands and Sweden. (orig.) [German] Die alten randomisiert-kontrollierten Studien erbrachten den Nachweis, dass durch Einladung zur Teilnahme an einem Mammmographiescreening mit/ohne klinische Untersuchung der Effekt der Mortalitaetsreduktion erreicht wird und unterstreichen die Sensitivitaet der Mammographie als Detektionstest. Juengste Kritik hat sich in der wissenschaftlichen Auseinandersetzung als unbegruendet herausgestellt. Randomisierte Studien unterschaetzen den Effekt, Beobachtungsstudien spiegeln besser das Ausmass des individuellen Nutzens. Die Uebertragung von Studienergebnissen in den Versorgungsalltag ist aeusserst schwierig, stellt hoechste Anforderungen an ein umfassendes Qualitaetsmanagement, ist jedoch machbar, wie Laender wie Grossbritannien, die Niederlande und Schweden zeigen. (orig.)

  16. High-grade histologic features of DCIS are associated with R5 rather than R3 calcifications in breast screening mammography.

    LENUS (Irish Health Repository)

    Hayes, Brian D

    2013-01-01

    Mammographic calcification is an important radiologic feature of early breast carcinoma whose index of suspicion for malignancy may be reported by a five-tier R-category system. This study aims to describe the histologic diagnoses underlying screen-detected mammographic calcifications using both digital and screen-film mammography, and to correlate these findings with radiologic R-categories. Patients attending the Merrion Breast Screening Unit in Dublin between 2000 and 2011 were identified, who underwent needle-core biopsy for assessment of mammographic calcifications without associated mass or architectural distortion. Radiologic R-category was correlated with biopsy and excision histology reports. A total of 776 cases of calcification were identified, involving 769 individual patients. The radiologic R-categories were as follows: R3 513 (66.1%), R4 192 (24.7%), R5 71 (9.1%). The positive predictive values for malignancy were R3 32.6%, R4 69.8%, R5 95.8%. Several histologic features of DCIS were associated with R5 rather than R3 radiology: high nuclear grade, solid or cribriform architecture, necrosis, periductal inflammation or fibrosis, and associated microinvasive or invasive carcinoma. Mammographic lesions and histologic whole and invasive tumors increased in size from R3 to R5. Radiologic size of calcifications correlated with whole (but not invasive) tumor size, although it tended to underestimate it by several millimeters. Digital-detected calcifications were more likely than screen-film detected to be categorized as R3 and less likely R4 or R5, and there was no significant difference in positive predictive value between the two imaging techniques in any R-category. In conclusion, histologic features of DCIS, in particular those associated with high grade, are associated with R5 radiology. There is no significant difference in positive predictive value for malignancy in any R-category between digital and screen-film mammography.

  17. Health-related quality of life, anxiety and depression related to mammography screening in Norway.

    Science.gov (United States)

    Hafslund, Bjorg; Espehaug, Birgitte; Nortvedt, Monica Wammen

    2012-11-01

    To measure health-related quality of life, anxiety and depression ahead of mammography screening and to assess any differences in health-related quality of life compared to reference population. The study of health-related quality of life among attendees prior to mammography screening has received little attention, and increased knowledge is needed to better understand the overall health benefits of participation. A two-group cross-sectional comparative study was performed. The samples comprised 4,249 attendees to mammography screening and a comparison group of 943 women. We used the SF-36 Health Survey to assess health-related quality of life. Linear regression was used to study any differences between the groups with adjustment for age, level of education, occupation, having children and smoking status. Other normative data were also used. Anxiety and depression were assessed using the Hospital Anxiety and Depression Scale. Attendees scored statistically significant higher on the SF-36 than the comparison group but were in line with normative data. Attendees had anxiety mean 4·1 and depression mean 2·6. The majority of the attendees have a high health-related quality of life, low anxiety and depression ahead of screening. Anxiety and depression were less than shown in normative data from Norway. Despite a high health-related quality of life, low anxiety and depression among the majority, healthcare workers should pay special attention to the few women who are anxious and depressed, and have a lower health-related quality of life. Omitted from mammography screening may be women who are unemployed, have lower socioeconomic status, are anxious and are depressed. Further research should be performed with non-attendees and subgroups to improve the screening programme. It is important to identify which patients have the greatest need for support and caring in an organised mammography screening and who may be overlooked. © 2012 Blackwell Publishing Ltd.

  18. Analysis on imaging features of mammography in computer radiography and investigation on gray scale transform and energy subtraction

    International Nuclear Information System (INIS)

    Feng Shuli

    2003-01-01

    In this dissertation, a novel transform method based on human visual response features for gray scale mammographic imaging in computer radiography (CR) is presented. The parameters for imaging quality on CR imaging for mammography were investigated experimentally. In addition, methods for image energy subtraction and a novel method of image registration for mammography of CR imaging are presented. Because the images are viewed and investigated by humans, the method of displaying differences in gray scale images is more convenient if the gray scale differences are displayed in a manner commensurate with human visual response principles. Through transformation of image gray scale with this method, the contrast of the image will be enhanced and the capability for humans to extract the useful information from the image will be increased. Tumors and microcalcifications are displayed in a form for humans to view more simply after transforming the image. The method is theoretically and experimentally investigated. Through measurement of the parameters of a geometrically blurred image, MTF, DQE, and ROC on CR imaging, and also comparison with the imaging quality of screen-film systems, the results indicate that CR imaging qualities in DQE and ROC are better than those of screen-film systems. In geometric blur of the image and MTF, the differences in image quality between CR and the screen-film system are very small. The results suggest that the CR system can replace the screen-film system for mammography imaging. In addition, the results show that the optimal imaging energy for CR mammography is about 24 kV. This condition indicates that the imaging energy of the CR system is lower than that of the screen-film system and, therefore, the x-ray dose to the patient for mammography with the CR system is lower than that with the screen-film system. Based on the difference of penetrability of x ray with different wavelength, and the fact that the part of the x-ray beam will pass

  19. Mammography Screening Uptake among Female Health Care Workers in Primary Health Care Centers in Palestine - Motivators and Barriers.

    Science.gov (United States)

    Nazzal, Zaher; Sholi, Hisham; Sholi, Suha; Sholi, Mohammad; Lahaseh, Rawya

    2016-01-01

    Early detection remains the cornerstone of breast cancer control in terms of outcome and survival. Thus far the only breast cancer screening method proven effective is mammography. The awareness of female health care workers (HCW) about breast cancer prevention is of vital importance, as their beliefs and behavior may have a major impact on other women. This study was designed to assess mammography screening uptake among female healthcare workers at primary healthcare centers, and to identify the primary motivators and barriers that affect uptake results. A cross sectional study design was used to assess mammography screening by 299 female healthcare workers who completed a self-administered questionnaire that assessed demographics, screening uptake, motivators and barriers. The mean age was 46 years (within age of risk). The majority (95.1%) demonstrated adequate knowledge about breast cancer and mammography screening and 50% of the participants reported having at least one mammogram; however only 21% of them had regularly scheduled mammograms. The most frequent reported motivator was the perceived benefit that early detection of breast cancer is important for its management (89.6%), followed by the belief that mammography can detect breast cancer before its symptoms appear (84.4%). On the other hand, the most frequent barrier reported was being busy (46.7%), followed by the lack of perceived susceptibility (41.5%). Mammography screening was found to be sub-optimal in a population of HCW's with 50 % stating that they received a mammogram at least once, and a minority reported regular screening. There is a pressing need for educational programs aimed at removing the barriers that limit compliance with recommendations for mammography screening, and to emphasize the importance of early detection in breast cancer treatment. Ensuring the availability and accessibility of screening services, particularly for healthcare workers within their work settings are other

  20. Quality assurance for screening mammography data collection systems in 22 countries.

    NARCIS (Netherlands)

    Klabunde, C.N.; Sancho-Garnier, H.; Broeders, M.E.A.C.; Thoresen, S.; Rodrigues, V.J.; Ballard-Barbash, R.

    2001-01-01

    OBJECTIVES: To document the mammography data that are gathered by the organized screening programs participating in the International Breast Cancer Screening Network (IBSN), the nature of their procedures for data quality assurance, and the measures used to assess program performance and impact.

  1. Long-term psychosocial consequences of false-positive screening mammography

    DEFF Research Database (Denmark)

    Brodersen, John; Siersma, Volkert Dirk

    2013-01-01

    Cancer screening programs have the potential of intended beneficial effects, but they also inevitably have unintended harmful effects. In the case of screening mammography, the most frequent harm is a false-positive result. Prior efforts to measure their psychosocial consequences have been limite...... by short-term follow-up, the use of generic survey instruments, and the lack of a relevant benchmark-women with breast cancer....

  2. Optimization of technique factors for a silicon diode array full-field digital mammography system and comparison to screen-film mammography with matched average glandular dose

    International Nuclear Information System (INIS)

    Berns, Eric A.; Hendrick, R. Edward; Cutter, Gary R.

    2003-01-01

    Contrast-detail experiments were performed to optimize technique factors for the detection of low-contrast lesions using a silicon diode array full-field digital mammography (FFDM) system under the conditions of a matched average glandular dose (AGD) for different techniques. Optimization was performed for compressed breast thickness from 2 to 8 cm. FFDM results were compared to screen-film mammography (SFM) at each breast thickness. Four contrast-detail (CD) images were acquired on a SFM unit with optimal techniques at 2, 4, 6, and 8 cm breast thicknesses. The AGD for each breast thickness was calculated based on half-value layer (HVL) and entrance exposure measurements on the SFM unit. A computer algorithm was developed and used to determine FFDM beam current (mAs) that matched AGD between FFDM and SFM at each thickness, while varying target, filter, and peak kilovoltage (kVp) across the full range available for the FFDM unit. CD images were then acquired on FFDM for kVp values from 23-35 for a molybdenum-molybdenum (Mo-Mo), 23-40 for a molybdenum-rhodium (Mo-Rh), and 25-49 for a rhodium-rhodium (Rh-Rh) target-filter under the constraint of matching the AGD from screen-film for each breast thickness (2, 4, 6, and 8 cm). CD images were scored independently for SFM and each FFDM technique by six readers. CD scores were analyzed to assess trends as a function of target-filter and kVp and were compared to SFM at each breast thickness. For 2 cm thick breasts, optimal FFDM CD scores occurred at the lowest possible kVp setting for each target-filter, with significant decreases in FFDM CD scores as kVp was increased under the constraint of matched AGD. For 2 cm breasts, optimal FFDM CD scores were not significantly different from SFM CD scores. For 4-8 cm breasts, optimum FFDM CD scores were superior to SFM CD scores. For 4 cm breasts, FFDM CD scores decreased as kVp increased for each target-filter combination. For 6 cm breasts, CD scores decreased slightly as k

  3. Average glandular dose in routine mammography screening using a Sectra Microdose Mammography unit

    International Nuclear Information System (INIS)

    Hemdal, B.; Herrnsdorf, L.; Andersson, I.; Bengtsson, G.; Heddson, B.; Olsson, M.

    2005-01-01

    The Sectra MicroDose Mammography system is based on direct photon counting (with a solid-state detector), and a substantially lower dose to the breast than when using conventional system can be expected. In this work absorbed dose measurements have been performed for the first unit used in routine mammography screening (at the Hospitals of Helsingborg (Sweden)). Two European protocols on dosimetry in mammography have been followed. Measurement of half value layer (HVL) cannot be performed as prescribed, but this study has demonstrated than non-invasive measurements of HVL can be performed accurately with a sensitive and well collimated solid-state detector with simultaneous correction for the energy dependence. The average glandular dose for a 50 mm standard breast with 50% glandularity, simulated by 45 mm polymethylmethacrylate, was found to be 0.21 and 0.28 mGy in March and December 2004, respectively. These values are much lower than for any other mammography system on the market today. It has to be stressed that the measurement were made using the current clinical settings and that no systematic optimisation of the relationship between absorbed dose and diagnostic image quality has been performed within the present study. In order to further increase the accuracy of absorbed dose measurements for this unit, the existing dose protocols should be revised to account also for the tungsten/aluminium anode/filter combination, the multi-slit pre-collimator device and the occurrence of a dose profile in the scanning direction. (authors)

  4. Establishing daily quality control (QC) in screen-film mammography using leeds tor (max) phantom at the breast imaging unit of USTH-Benavides Cancer Institute

    Science.gov (United States)

    Acaba, K. J. C.; Cinco, L. D.; Melchor, J. N.

    2016-03-01

    Daily QC tests performed on screen film mammography (SFM) equipment are essential to ensure that both SFM unit and film processor are working in a consistent manner. The Breast Imaging Unit of USTH-Benavides Cancer Institute has been conducting QC following the test protocols in the IAEA Human Health Series No.2 manual. However, the availability of Leeds breast phantom (CRP E13039) in the facility made the task easier. Instead of carrying out separate tests on AEC constancy and light sensitometry, only one exposure of the phantom is done to accomplish the two tests. It was observed that measurements made on mAs output and optical densities (ODs) using the Leeds TOR (MAX) phantom are comparable with that obtained from the usual conduct of tests, taking into account the attenuation characteristic of the phantom. Image quality parameters such as low contrast and high contrast details were also evaluated from the phantom image. The authors recognize the usefulness of the phantom in determining technical factors that will help improve detection of smallest pathological details on breast images. The phantom is also convenient for daily QC monitoring and economical since less number of films is expended.

  5. Motivators and barriers to mammography screening uptake by female health-care workers in primary health-care centres: a cross-sectional study.

    Science.gov (United States)

    Nazzal, Zaher; Sholi, Hisham; Sholi, Suha B; Sholi, Mohammad B; Lahaseh, Rawya

    2018-02-21

    Mammography screening is an effective tool for early detection and management of breast cancer. Female health-care workers' awareness of breast cancer screening is important because their beliefs and behaviours could influence other women. The aim of this study was to assess mammography screening uptake by female health-care workers at primary health-care centres and to identify the primary motivators and barriers that affect uptake. This cross-sectional study included all governmental primary health-care centres in the West Bank. Governorates were grouped into three regions as follows: north West Bank (Nablus, Jenin, Tulkarm, Tubas, Qalqiliya, and Salfit), middle West Bank (Jerusalem, Jericho, and Ramallah), and south West Bank (Hebron, and Bethlehem). The study population included all female health-care workers older than 40 years. Those who performed mammography for a suspected mass or other breast abnormalities were excluded. A self-administered questionnaire was used to collect data on demographic characteristics, knowledge about mammography screening, the extent and regularity of mammography screening, and motivators and barriers influencing their mammography screening uptake. The rate of mammography screening uptake was calculated. χ 2 test and t tests were used to assess screening motivators and barriers. The study was approved by the Institutional Review Board of the An-Najah National University. Participation was voluntary, and written consent was obtained from each participant. 299 female health-care workers completed a self-administered questionnaire. The mean age of the participants was 46 years (SD 4·7). 284 (95%) women had adequate knowledge about breast cancer and mammography screening, and 149 (50%) women reported having had at least one mammogram. 62 (21%) women had had regular scheduled mammograms. The most frequent reported motivators were the perceived benefit that early detection of breast cancer is important for its management (269 [90

  6. Design and Construction of a Test Phantom for Screen/Film Mammography Quality Control

    International Nuclear Information System (INIS)

    Galvan, Hector; Grabski, Varlen; Ruiz, Cesar; Brandan, Maria-Ester; Villasenor, Yolanda

    2006-01-01

    A 10 x 10 x 4 cm Lucite phantom for quality control tests in mammography has been designed and built. It contains internal elements to quantify contrast and resolution, a mixture of talc and Lucite fibers to simulate the breast architecture, a 9-step aluminum wedge to verify the constancy of the film developing process, and metallic foils to evaluate kVp. Associated with an ionization chamber, the mean glandular dose can be evaluated. Its performance has been compared against the phantom accredited by the American College of Radiology. For a series of kV, both phantoms OD are similar within 5%. The step wedge can detect developer temperature changes of ±1 deg. C. Relative metal foils/acrylic OD permits to calculate kVp with precision of ±0.43 kV. Radiological measurements have been interpreted by numerical calculations

  7. Mammography screening. Benefits, harms, and informed choice.

    Science.gov (United States)

    Jørgensen, Karsten Juhl

    2013-04-01

    The rationale for breast cancer screening with mammography is deceptively simple: catch it early and reduce mortality from the disease and the need for mastectomies. But breast cancer is a complex problem, and complex problems rarely have simple solutions. Breast screening brings forward the time of diagnosis only slightly compared to the lifetime of a tumour, and screen-detected tumours have a size where metastases are possible. A key question is if screening can prevent metastases, and if the screen-detected tumours are small enough to allow breast conserving surgery rather than mastectomy. A mortality reduction can never justify a medical intervention in its own right, but must be weighed against the harms. Overdiagnosis is the most important harm of breast screening, but has gained wider recognition only in recent years. Screening leads to the detection and treatment of breast cancers that would otherwise never have been detected because they grow very slowly or not at all and would not have been detected in the woman's lifetime in the absence of screening. Screening therefore turns women into cancer patients unnecessarily, with life-long physical and psychological harms. The debate about the justification of breast screening is therefore not a simple question of whether screening reduces breast cancer mortality. This dissertation quantifies the primary benefits and harms of screening mammography. Denmark has an unscreened "control group" because only two geographical regions offered screening over a long time-period, which is unique in an international context. This was used to study breast cancer mortality, overdiagnosis, and the use of mastectomies. Also, a systematic review of overdiagnosis in five other countries allowed us to show that about half of the screen-detected breast cancers are overdiagnosed. An effect on breast cancer mortality is doubtful in today's setting, and overdiagnosis causes an increase in the use of mastectomies. These findings are

  8. Comparing sensitivity and specificity of screening mammography in the United States and Denmark

    DEFF Research Database (Denmark)

    Kemp Jacobsen, Katja; O'Meara, Ellen S; Key, Dustin

    2015-01-01

    Delivery of screening mammography differs substantially between the United States (US) and Denmark. We evaluated whether there are differences in screening sensitivity and specificity. We included screens from women screened at age 50-69 years during 1996-2008/2009 in the US Breast Cancer...

  9. Breast Cancer Detection: Mammography and other methods in breast imaging, second edition

    International Nuclear Information System (INIS)

    Bassett, L.W.; Gold, R.H.

    1987-01-01

    The text addresses mammography and the advantages and limitations of other breast imaging methods presently available. The establishment of X-ray mammography as the safest and most accurate noninvasive method of early, nonpalpable breast cancer detection is addressed in the first section of the book. The second section emphasizes the signs of early cancer, the complete mammographic examination, and the team approach to diagnosis. The advantages and limitations of film-screen mammography, zero mammography, breast ultrasound, thermography, light scanning, magnetic resonance imaging, and ductography are highlighted as alternate methods of detection. The benefits of mammography, and its unmatched value in screeening for breast cancer, are presented in the final section

  10. Evaluation of the mammography screening studies conducted in Europe and North America

    International Nuclear Information System (INIS)

    Schreer, I.

    2001-01-01

    The ancient randomized-controlled trials of breast cancer screening have offered clear evidence that invitation to participate in mammography screening with/without clinical examination is effective in breast cancer mortality reduction and underline the detection sensitivity of mammography. Recently published criticism of both the effect and fundamental data handling could be shown to be untenable. Randomized studies underestimate the effect while well-designed observational studies do not systematically overestimate the magnitude of the effect. To transform high-quality study results in all-day's practice is a huge challenge, but affordable as has been demonstrated in Great Britain, the Netherlands and Sweden. (orig.) [de

  11. The personal costs and convenience of screening mammography.

    Science.gov (United States)

    Suter, Lisa Gale; Nakano, Connie Y; Elmore, Joann G

    2002-09-01

    Few studies have examined the impact of women's personal costs on obtaining a screening mammogram in the United States. All women obtaining screening mammograms at nine Connecticut mammography facilities during a 2-week study period were asked to complete a questionnaire. Facilities included urban and rural fixed sites and mobile sites. The survey included questions about insurance coverage, mammogram payment, and personal costs in terms of transportation, family care, parking, and lost work time from the women's perspective. The response rate was 62% (731 of 1189). Thirty-two percent of respondents incurred some type of personal cost, including lost work time, family care, and parking. Women incurring personal costs were more likely than those without personal costs to attend an urban facility (46% vs. 23%, p convenience and 17% listed cost as a reason for choosing a mammography facility; 23% reported that cost might prevent them from obtaining a future mammogram. One third of women obtaining mammograms may be incurring personal costs. These personal costs should be considered in future cost-effectiveness analyses.

  12. Investigation of breast dose in five screening mammography centres in Greece

    International Nuclear Information System (INIS)

    Tsapaki, V; Tsalafoutas, I A; Poga, V; Louizi, A; Kottou, S; Koulentianos, E

    2008-01-01

    The objectives of this study were to investigate the techniques currently used for screening mammography in Greece, to estimate the mean glandular dose (MGD) for establishing a baseline radiation dose database, to analyse the effects of various factors on MGD, and to compare the results with others in the literature. Five mammographic facilities and 250 women having as a routine screening mammogram one craniocaudal (CC) and one mediolateral oblique (MLO) projection in each breast were included in the study. The parameters recorded were age, weight, compressed breast thickness (CBT), tube potential (kV), tube loading (mA s) and MLO projection angle. Large differences were observed among the different mammography facilities, mainly in terms of the tube potential setting and the MLO angle used. The average MGD per exposure was 1.4 ± 0.6 mGy while the respective averages separately for the CC and MLO projections were 1.2 ± 0.5 and 1.5 ± 0.7 mGy, respectively. The average MGD values recorded in this study were below the limit of 2 mGy established for the reference medium-sized breast of 4.5 cm CBT. However, the variety of techniques observed revealed the need for a nationwide survey concerning screening mammography in Greece

  13. Investigation of breast dose in five screening mammography centres in Greece

    Energy Technology Data Exchange (ETDEWEB)

    Tsapaki, V [Medical Physics Department, Konstantopoulio Hospital, Nea Ionia, 142 33, Athens (Greece); Tsalafoutas, I A [Medical Physics Department, Agios Savvas Hospital, 171 Alexandras Avenue, 115 22, Athens (Greece); Poga, V; Louizi, A; Kottou, S [Medical Physics Department, Medical School, Athens University, University of Athens, 75 Mikras Asias, 115 27, Athens (Greece); Koulentianos, E [Radiology Department, Konstantopoulio Hospital, Nea Ionia, 142 33, Athens (Greece)

    2008-09-01

    The objectives of this study were to investigate the techniques currently used for screening mammography in Greece, to estimate the mean glandular dose (MGD) for establishing a baseline radiation dose database, to analyse the effects of various factors on MGD, and to compare the results with others in the literature. Five mammographic facilities and 250 women having as a routine screening mammogram one craniocaudal (CC) and one mediolateral oblique (MLO) projection in each breast were included in the study. The parameters recorded were age, weight, compressed breast thickness (CBT), tube potential (kV), tube loading (mA s) and MLO projection angle. Large differences were observed among the different mammography facilities, mainly in terms of the tube potential setting and the MLO angle used. The average MGD per exposure was 1.4 {+-} 0.6 mGy while the respective averages separately for the CC and MLO projections were 1.2 {+-} 0.5 and 1.5 {+-} 0.7 mGy, respectively. The average MGD values recorded in this study were below the limit of 2 mGy established for the reference medium-sized breast of 4.5 cm CBT. However, the variety of techniques observed revealed the need for a nationwide survey concerning screening mammography in Greece.

  14. Clinical evaluation of a new set of image quality criteria for mammography

    International Nuclear Information System (INIS)

    Grahn, A.; Hemdal, B.; Andersson, I.; Ruschin, M.; Thilander-Klang, A.; Boerjesson, S.; Tingberg, A.; Mattsson, S.; Haakansson, M.; Baath, M.; Maansson, L. G.; Medin, J.; Wanninger, F.; Panzer, W.

    2005-01-01

    The European Commission (EC) quality criteria for screen-film mammography are used as a tool to asses image quality. A new set of criteria was developed and initially tested in a previous study. In the present study, these criteria are further evaluated using screen-film mammograms that have been digitised, manipulated to simulated different image quality level and reprinted on film. Expert radiologists have evaluated these manipulated to simulate different image quality levels and reprinted on film. Expert radiologists have evaluated these manipulated images using both the original (EC) and the new criteria. A comparison of three different simulated dose levels that the new criteria yield a larger separation of image criteria scores than the old ones. These results indicated that the new set of image quality criteria has a higher discriminative power than the old set and thus seems to be more suitable for evaluation of image quality in mammography. (authors)

  15. Digital breast tomosynthesis (3D-mammography) screening: A pictorial review of screen-detected cancers and false recalls attributed to tomosynthesis in prospective screening trials.

    Science.gov (United States)

    Houssami, Nehmat; Lång, Kristina; Bernardi, Daniela; Tagliafico, Alberto; Zackrisson, Sophia; Skaane, Per

    2016-04-01

    This pictorial review highlights cancers detected only at tomosynthesis screening and screens falsely recalled in the course of breast tomosynthesis screening, illustrating both true-positive (TP) and false-positive (FP) detection attributed to tomosynthesis. Images and descriptive data were used to characterise cases of screen-detection with tomosynthesis, sourced from prospective screening trials that performed standard (2D) digital mammography (DM) and tomosynthesis (3D-mammography) in the same screening participants. Exemplar cases from four trials highlight common themes of relevance to screening practice including: the type of lesions frequently made more conspicuous or perceptible by tomosynthesis (spiculated masses, and architectural distortions); the histologic findings (both TP and FP) of tomosynthesis-only detection; and the need to extend breast work-up protocols (additional imaging including ultrasound and MRI, and tomosynthesis-guided biopsy) if tomosynthesis is adopted for primary screening. Copyright © 2016 Elsevier Ltd. All rights reserved.

  16. Breast screening with mammography: Overview of Swedish randomized trials

    International Nuclear Information System (INIS)

    Nystroem, L.; Wall, S.; Lindqvist, M.; Ryden, S.; Andersson, J.; Bjurstam, N.; Fagerberg, G.; Frisell, J.; Tabar, L.; Larson, L.G.

    1993-01-01

    Despite encouraging results from screening trials the efficacy of mammography in reducing mortality remains somewhat controversial. Five studies have been done in Sweden. This overview, reveals a 24% significant reduction of breast cancer mortality among those invited to mammography screening compared with those not invited. To avoid the potential risk of differential misclassification causes of death were assessed by an independent end-point committee after a blinded review of all fatal breast cancer cases. The mortality reduction was similar, irrespective of the end-point used for evaluation (breast cancer as underlying cause of death or breast cancer present at death). There was a consistent risk reduction associated with screening in all studies, although the point estimate of the relative risk for all ages varied non-significantly between 0.68 and 0.84. The cumulative breast cancer mortality by time since randomization was estimated at 1.3 per 1,000 within 6 years in the invited group compared with 1.6 in the control group. The corresponding figures after 9 years are 2.6 and 3.3 and after 12 years 3.9 and 5.1

  17. Factors influencing elderly women's mammography screening decisions: implications for counseling

    OpenAIRE

    Schonberg, Mara A; McCarthy, Ellen P; York, Meghan; Davis, Roger B; Marcantonio, Edward R

    2007-01-01

    Abstract Background Although guidelines recommend that clinicians consider life expectancy before screening older women for breast cancer, many older women with limited life expectancies are screened. We aimed to identify factors important to mammography screening decisions among women aged 80 and older compared to women aged 65–79. Methods Telephone surveys of 107 women aged 80+ and 93 women aged 65–79 randomly selected from one academic primary care practice who were able to communicate in ...

  18. Radiation dose in mammography: an energy-balance approach

    International Nuclear Information System (INIS)

    Shrivastava, P.N.

    1981-01-01

    An energy-balance approach for calculation of mean, integral, and midpoint doses in mammography is introduced. Estimation of mean absorbed dose for individual applications is described. Differences in breast composition and thickness are accounted for by simple measurements of entrance and exit exposures. Calculations made for a range of xeromammographic techniques used at various breast cancer detection centers show that although increasing the beam h.v.l. dramatically decreases breast surface exposure, it is insignificant in lowering mean breast dose or radiation risk. Thus selection of a moderate h.v.l. to optimize image quality (soft-tissue contrast) in xeromammography may be more beneficial than unduly increasing h.v.l. merely to reduce surface exposure. The mean breast dose per mammogram with low-h.v.l. screen-film techniques was 3 to 9 times lower than for xeromammography, suggesting that general acceptance of screen-film techniques can significantly reduce the risk associated with mammography

  19. Direct Interactive Public Education by Breast Radiologists About Screening Mammography: Impact on Anxiety and Empowerment.

    Science.gov (United States)

    Lee, Jiyon; Hardesty, Lara A; Kunzler, Nathan M; Rosenkrantz, Andrew B

    2016-01-01

    Anxiety has been called a "harm" of screening mammography. The authors provided direct, interactive education to lay audiences and measured these sessions' impact on anxiety and any increased understanding of breast cancer screening. Academic breast radiologist provided seven 1-hour sessions of structured lectures and question-and-answer periods. Lay language and radiologic images were used to discuss disease background, screening guidelines, and areas of debate. One hundred seventeen participants (mean age, 45 ± 15 years) completed voluntary, anonymous, institutional review board-approved pre and postsession questionnaires relaying their attitudes regarding screening and the impact of the sessions. Results are summarized descriptively. Mean reported anxiety regarding screening (on a scale ranging from 1-5; 1 = no anxiety) was 2.5 ± 1.3. Anxiety was attributed to unknown results (56.4%), anticipation of pain (21.8%), known risk factors (14.5%), general uncertainty (12.7%), waiting for results (9.1%), possibility of more procedures (3.6%), and personal breast cancer history (3.6%). Ninety-seven percent reported that immediate results would lower anxiety (78% of those women indicated a 75%-100% decrease in anxiety); 93% reported that radiologist consultation with images would lower anxiety (75.6% indicated a 75%-100% decrease in anxiety). After the lecture, women reported (on a scale ranging from 1-5) increased understanding of the topic (4.7 ± 0.6), encouragement to screen (4.6 ± 0.7), and reduced anxiety (4.0 ± 1.1). Ninety-seven percent to 100% provided correct responses to these questions: rationale for screening in the absence of family history, recall does not equate to cancer diagnosis, benefit of prior films, and continued importance of physical examination. Attendees of radiologist-provided direct public lectures reported decreased anxiety and improved knowledge regarding screening mammography. The resultant reduced anxiety ("harm") and educational

  20. Screening for breast cancer with mammography

    DEFF Research Database (Denmark)

    Gøtzsche, Peter C; Nielsen, Margrethe

    2009-01-01

    BACKGROUND: A variety of estimates of the benefits and harms of mammographic screening for breast cancer have been published and national policies vary. OBJECTIVES: To assess the effect of screening for breast cancer with mammography on mortality and morbidity. SEARCH STRATEGY: We searched Pub...... excluded a biased trial and included 600,000 women in the analyses. Three trials with adequate randomisation did not show a significant reduction in breast cancer mortality at 13 years (relative risk (RR) 0.90, 95% confidence interval (CI) 0.79 to 1.02); four trials with suboptimal randomisation showed...... a significant reduction in breast cancer mortality with an RR of 0.75 (95% CI 0.67 to 0.83). The RR for all seven trials combined was 0.81 (95% CI 0.74 to 0.87). We found that breast cancer mortality was an unreliable outcome that was biased in favour of screening, mainly because of differential...

  1. Significance of screening mammography in the detection of breast diseases

    International Nuclear Information System (INIS)

    Ham, Soo Youn; Kim, Kyoung Ah; Oh, Yu Whan; Kim, Hong In; Chung, Kyoo Byung

    1995-01-01

    To evaluate the clinical significance of the screening mammography in the detection of the breast diseases, especially breast carcinoma. We analyzed 1,800 cases of mammography retrospectively. The mammography was done as a part of routine check in Health Counselling Center, Korea University Medical Center, during 9 months from November 1993 to July 1994. The age range was from 23 years to 76 years, mean 49.8 years, and the largest age group was 6th decade (31.4%). According to the mammographic findings, we divided the subjects into three groups; normal group, abnormal group in need of follow-up study, abnormal group requiring biopsy. On mammography, the normal group consisted of 1,534 cases (85%), and the abnormal group consisted of 266 cases (15%). The abnormal findings were benign-looking calcification (n = 140), fibroadeno ma (n = 29), fibrocystic changes (n = 27), cyst (n = 23), malignant lesion (n = 15) lipoma (n = 7), and others. In four of 15 cases, which were suspected to be malignant on mammograms, breast carcinoma was confirmed pathologically. In four cases of breast carcinoma, one was under 40 and the other 3 were over 50 years of age. All of the breast cancers were under 3 cm in size, and the mammographic findings of breast cancer included spiculated margin (n = 3), parenchymal distortion (n = 3), malignant calcification (n = 2) and enlarged axillary node (n = 1). Screening mammogram is helpful for early detection of non-palpable breast cancer, especially for women over 50 years of age

  2. Significance of screening mammography in the detection of breast diseases

    Energy Technology Data Exchange (ETDEWEB)

    Ham, Soo Youn; Kim, Kyoung Ah; Oh, Yu Whan; Kim, Hong In; Chung, Kyoo Byung [College of Medicine Korea University, Seoul (Korea, Republic of)

    1995-02-15

    To evaluate the clinical significance of the screening mammography in the detection of the breast diseases, especially breast carcinoma. We analyzed 1,800 cases of mammography retrospectively. The mammography was done as a part of routine check in Health Counselling Center, Korea University Medical Center, during 9 months from November 1993 to July 1994. The age range was from 23 years to 76 years, mean 49.8 years, and the largest age group was 6th decade (31.4%). According to the mammographic findings, we divided the subjects into three groups; normal group, abnormal group in need of follow-up study, abnormal group requiring biopsy. On mammography, the normal group consisted of 1,534 cases (85%), and the abnormal group consisted of 266 cases (15%). The abnormal findings were benign-looking calcification (n = 140), fibroadeno ma (n = 29), fibrocystic changes (n = 27), cyst (n = 23), malignant lesion (n = 15) lipoma (n = 7), and others. In four of 15 cases, which were suspected to be malignant on mammograms, breast carcinoma was confirmed pathologically. In four cases of breast carcinoma, one was under 40 and the other 3 were over 50 years of age. All of the breast cancers were under 3 cm in size, and the mammographic findings of breast cancer included spiculated margin (n = 3), parenchymal distortion (n = 3), malignant calcification (n = 2) and enlarged axillary node (n = 1). Screening mammogram is helpful for early detection of non-palpable breast cancer, especially for women over 50 years of age.

  3. Perspectives of Mobile Versus Fixed Mammography in Santa Clara County, California: A Focus Group Study.

    Science.gov (United States)

    Chen, Yi-Ren; Chang-Halpenny, Christine; Kumarasamy, Narmadan A; Venegas, Angela; Braddock Iii, Clarence H

    2016-02-12

    Our aim was to examine underserved women's perceptions on mobile versus fixed mammography in Santa Clara, California through a focus group study.  Research has shown that medically underserved women have higher breast cancer mortality rates correlated with under-screening and a disproportional rate of late-stage diagnosis. The Community Health Partnership in Santa Clara County, California runs the Community Mammography Access Project (CMAP) that targets nearly 20,000 medically underserved women over the age of 40 in the county through the collaborative effort of an existing safety net of healthcare providers. However, little data exists on the advantages or disadvantages of mobile mammography units from the patient perspective.   We assessed underserved women's perspectives on mammography services in Santa Clara County through two focus groups from women screened at mobile or fixed site programs. Patients were recruited from both CMAP clinics and a county hospital, and focus group data were analyzed using content analysis.  We found that women from both the mobile and fixed sites shared similar motivating factors for getting a mammogram. Both groups recognized that screening was uncomfortable but necessary for good health and had positive feedback about their personal physicians. However, mobile participants, in particular, appreciated the atmosphere of mobile screening, reported shorter wait times, and remarked on the good communication from the clinic staff and empathetic treatment they received. However, mobile participants also expressed concern about the quality of films at mobile sites due to delayed initial reading of the films.   Mobile mammography offers a unique opportunity for women of underserved populations to access high satisfaction screenings, and it encourages a model similar to CMAP in other underserved areas. However, emphasis should be placed on providing a warm and welcoming environment for patients and ensuring the quality of

  4. Screening mammography. A risk versus risk decision

    International Nuclear Information System (INIS)

    Ritenour, E.R.; Hendee, W.R.

    1989-01-01

    The potential risk of a radiologic procedure often is compared with the potential benefit of the procedure. While risk vs. benefit analysis has been useful as a step toward increased communication and understanding among radiologists, referring physicians, and the general public, it has the disadvantage that risk and benefit are fundamentally different quantities. Hence, their juxtaposition for purposes of comparison presents contextual difficulties. In this article, the concept is presented of comparing the risk of doing a procedure with the risk of choosing not to do the procedure. An example of risk vs. risk analysis of screening mammography for women over the age of 50 is given, with the conclusion that the risk of having yearly mammograms is less than 1/10 the risk of early death caused by failure to diagnose breast cancer by x-ray mammography. This approach to risk analysis would yield interesting data for examinations that are part of more complicated diagnostic pathways.19 references

  5. Comparative performance of modern digital mammography systems in a large breast screening program

    Energy Technology Data Exchange (ETDEWEB)

    Yaffe, Martin J., E-mail: martin.yaffe@sri.utoronto.ca; Bloomquist, Aili K.; Hunter, David M.; Mawdsley, Gordon E. [Physical Sciences Division, Sunnybrook Research Institute, Departments of Medical Biophysics and Medical Imaging, University of Toronto, Ontario M4N 3M5 (Canada); Chiarelli, Anna M. [Prevention and Cancer Control, Cancer Care Ontario, Dalla Lana School of Public Health, University of Toronto, Ontario M4N 3M5, Canada and Ontario Breast Screening Program, Cancer Care Ontario, Toronto, Ontario M5G 1X3 (Canada); Muradali, Derek [Ontario Breast Screening Program, Cancer Care Ontario, Toronto, Ontario M5G 1X3 (Canada); Mainprize, James G. [Physical Sciences Division, Sunnybrook Research Institute, Toronto, Ontario M4N 3M5 (Canada)

    2013-12-15

    Purpose: To compare physical measures pertaining to image quality among digital mammography systems utilized in a large breast screening program. To examine qualitatively differences in these measures and differences in clinical cancer detection rates between CR and DR among sites within that program. Methods: As part of the routine quality assurance program for screening, field measurements are made of several variables considered to correlate with the diagnostic quality of medical images including: modulation transfer function, noise equivalent quanta, d′ (an index of lesion detectability) and air kerma to allow estimation of mean glandular dose. In addition, images of the mammography accreditation phantom are evaluated. Results: It was found that overall there were marked differences between the performance measures of DR and CR mammography systems. In particular, the modulation transfer functions obtained with the DR systems were found to be higher, even for larger detector element sizes. Similarly, the noise equivalent quanta, d′, and the phantom scores were higher, while the failure rates associated with low signal-to-noise ratio and high dose were lower with DR. These results were consistent with previous findings in the authors’ program that the breast cancer detection rates at sites employing CR technology were, on average, 30.6% lower than those that used DR mammography. Conclusions: While the clinical study was not large enough to allow a statistically powered system-by-system assessment of cancer detection accuracy, the physical measures expressing spatial resolution, and signal-to-noise ratio are consistent with the published finding that sites employing CR systems had lower cancer detection rates than those using DR systems for screening mammography.

  6. Experimental study on image quality when using screens in mammography

    International Nuclear Information System (INIS)

    Maurer, H.J.; Goos, F.

    1979-01-01

    1) Different types of screens and X-ray films have been investigated using a Kodak mamma-phantom I.T.O. 745 and compared with conventional non screen industrial film radiography. 2) Dosisreduction by using screens depends on the used film/screen system. It is possible to reach a relation of 1:10. 3) The information depends on type of screen and of type of film. Therefore, it is possible to reach the information of non screen industrial film radiographs. 4) A suitable film/screen system allows without loss of any diagnostic information to replace non screen industrial films needing a high exposure dosis by a film/screen system needing decreased dosis. (orig.) [de

  7. Glandular dose and image quality control in mammography facilities with computerized radiography systems

    International Nuclear Information System (INIS)

    Dantas, Marcelino Vicente de Almeida

    2010-01-01

    Breast cancer is the most common cancer among women, and early detection is critical to its diagnosis and treatment. To date, the most effective method for early detection of breast cancer has been x-ray mammography for which the screen/film (SF) technique has been the gold standard. However, even though SF combinations have been improved and optimized over the years for breast imaging, there are some critical limitations, including a narrow exposure range, image artifacts, film processing problems, and inflexibility in image processing and film management. In recent years, digital mammography has been introduced in cancer screening programmes with the screen/film techniques gradually being phased out. Computed radiography (CR), also commonly known as photostimulable phosphor (PSP) imaging or storage phosphor, employs reusable imaging plates and associated hardware and software to acquire and to display digital projection radiographs. In this work, a protocol model was tested for performing image quality control and average glandular dose (AGD) evaluation in 19 institutions with computed radiography systems for mammography. The protocol was validated through tests at the Laboratorio de Radioprotecao Aplicada a Mamografia (LARAM) from the Centro de Desenvolvimento da Tecnologia Nuclear (CDTN). The image quality visual evaluation of CDMAM phantom showed that 53% of the facilities were able to produce images of excellent quality. Furthermore, the automated evaluation of image quality, using the analyze software cdcom.exe, showed that 57% of the images were considered to be of good quality. The detector linearity test showed that the CR response is very linear, where 95% of facilities evaluated were considered to be compliant. For the image noise was found that only 20% of facilities are in agreement with the parameters established for this test. The average glandular doses, which patients may be getting to perform an examination, were below the action levels

  8. Implementation of Quality Control Protocol in Mammography: A Serbian Experience

    International Nuclear Information System (INIS)

    Ciraj Bjelac, O.; Kosutic, D.; Arandjic, D.; Kovacevic, M.

    2008-01-01

    Mammography is method of choice for early detection of breast cancer. In Serbia, mammography is performed only clinically, although there is a long term plan to introduce mammography as screening method. Currently there are 60 mammography units in practice in Serbia, resulting with 70 000 mammographies annually. The purpose of this paper is preliminary evaluation of the mammography practice in Serbia, having in mind the annual number of examinations and fact that part of examination is performed on women without any clinical signs. For pilot implementation of Quality Control (QC) protocol in mammography, five hospitals with highest workload have been selected, representing the typical mammography practice in Serbia. Developed QC protocol, based on European guidelines for quality assurance in breast cancer screening and diagnosis, actual practice and resources, includes equipment testing and maintenance, staff training and QC management and allocation of responsibilities. Subsequently, it should be applied on the national scale. The survey demonstrated considerable variations in technical parameters that affect image quality and patients doses. Mean glandular doses ranged from 0.12 to 2.8 mGy, while reference optical density ranged from 1.2 to 2.8. Main problems were associated with film processing, viewing conditions and optical density control. The preliminary survey of mammography practice highlighted the need for optimization of radiation protection and training of operating staff, although the survey itself was very valuable learning process for all participants. Furthermore, systematic implementation of QC protocol should provide reliable performance of mammography units and maintain satisfactory image quality and keep patient doses as low as reasonably practical.(author)

  9. Socioeconomic status as determinant for participation in mammography screening: assessing the difference between using women's own versus their partner's

    DEFF Research Database (Denmark)

    Kjellén, Malin; von Euler-Chelpin, My

    2010-01-01

    Earlier research has shown that participation in mammography screening tends to vary across socioeconomic levels. We assessed the difference between using the woman's own socioeconomic status (SES) and using that of her household or partner as determinant of participation in mammography screening....

  10. Breast density in screening mammography in Indian population - Is it different from western population?

    Science.gov (United States)

    Singh, Tulika; Khandelwal, Niranjan; Singla, Veenu; Kumar, Dileep; Gupta, Madhu; Singh, Gurpreet; Bal, Amanjit

    2018-05-01

    Mammography is the only method presently considered appropriate for mass screening of breast cancer. However, higher breast density was strongly associated with lower mammographic sensitivity. Breast density is also identified as independent and strongest risk factors for breast cancer. Studies have shown women with high breast density have four to six times increased risk of breast cancer as compare to women with fatty breast. It varies between different age group it generally decreases with increasing age in postmenopausal women and it can be different in different ethnic groups and people from different geographical areas. This study evaluates the breast density in Indian population and its relationship with the age. We reviewed of all screening mammography examinations performed from May 2012 to January 2015 at our institute PGIMER, Chandigarh, INDIA. Descriptive analyses were used to examine the association between age and breast density. A total of 6132 screening mammograms were performed. Each subgroup categorized by decade of age. There was a significant inverse relationship between age and breast density (P density in Indian and Western population with more Indians having ACR Grade 1 and 2 and Western population having 2 and 3. We found an inverse relationship between patient age and mammographic breast density. However, there were a large proportion of young women who had lower grades of mammographic density which could potentially benefit from the use of routine screening mammography in this subgroup of patients. Moreover, the breast density of Indian population is less when compared to the Western population. This might suggest that mammography is a good modality of choice for screening Indian population. © 2017 Wiley Periodicals, Inc.

  11. Adjunct Screening With Tomosynthesis or Ultrasound in Women With Mammography-Negative Dense Breasts: Interim Report of a Prospective Comparative Trial.

    Science.gov (United States)

    Tagliafico, Alberto S; Calabrese, Massimo; Mariscotti, Giovanna; Durando, Manuela; Tosto, Simona; Monetti, Francesco; Airaldi, Sonia; Bignotti, Bianca; Nori, Jacopo; Bagni, Antonella; Signori, Alessio; Sormani, Maria Pia; Houssami, Nehmat

    2016-03-09

    Debate on adjunct screening in women with dense breasts has followed legislation requiring that women be informed about their mammographic density and related adjunct imaging. Ultrasound or tomosynthesis can detect breast cancer (BC) in mammography-negative dense breasts, but these modalities have not been directly compared in prospective trials. We conducted a trial of adjunct screening to compare, within the same participants, incremental BC detection by tomosynthesis and ultrasound in mammography-negative dense breasts. Adjunct Screening With Tomosynthesis or Ultrasound in Women With Mammography-Negative Dense Breasts is a prospective multicenter study recruiting asymptomatic women with mammography-negative screens and dense breasts. Eligible women had tomosynthesis and physician-performed ultrasound with independent interpretation of adjunct imaging. Outcome measures included cancer detection rate (CDR), number of false-positive (FP) recalls, and incremental CDR for each modality; these were compared using McNemar's test for paired binary data in a preplanned interim analysis. Among 3,231 mammography-negative screening participants (median age, 51 years; interquartile range, 44 to 78 years) with dense breasts, 24 additional BCs were detected (23 invasive): 13 tomosynthesis-detected BCs (incremental CDR, 4.0 per 1,000 screens; 95% CI, 1.8 to 6.2) versus 23 ultrasound-detected BCs (incremental CDR, 7.1 per 1,000 screens; 95% CI, 4.2 to 10.0), P = .006. Incremental FP recall occurred in 107 participants (3.33%; 95% CI, 2.72% to 3.96%). FP recall (any testing) did not differ between tomosynthesis (FP = 53) and ultrasound (FP = 65), P = .26; FP recall (biopsy) also did not differ between tomosynthesis (FP = 22) and ultrasound (FP = 24), P = .86. The Adjunct Screening With Tomosynthesis or Ultrasound in Women With Mammography-Negative Dense Breasts' interim analysis shows that ultrasound has better incremental BC detection than tomosynthesis in mammography

  12. The effects of music on pain and anxiety during screening mammography.

    Science.gov (United States)

    Zavotsky, Kathleen Evanovich; Banavage, Adrienne; James, Patricia; Easter, Kathy; Pontieri-Lewis, Vicky; Lutwin, Lynn

    2014-06-01

    One in four women who are diagnosed with breast cancer die annually, and the single most important way to prevent this is early detection; therefore, women older than 40 years should have an annual screening mammography. Many barriers have been reported that prevent compliance with this recommendation, including lack of insurance, fear, anxiety, pain, worry, and mistrust of the medical community. Nurses are in a position to use creative interventions, such as music therapy, to help minimize barriers. Although this study did not show that music therapy during screening mammograms decreased the amount of pain that the participants experienced, it did suggest that music therapy has the potential to decrease the amount of anxiety. Assisting patients in decreasing anxiety reduces barriers for screening mammography. The literature does suggest that music is a distraction for many populations of patients; however, when patients are faced with the possible diagnosis of breast cancer, it may be difficult to find an intervention to distract a woman's mind, which was supported by the findings of this study.

  13. Studies of breast masses in Korean woman using tungsten anode mammography

    International Nuclear Information System (INIS)

    Suh, C. O.; Oh, K. K.; Lee, K. S.

    1979-01-01

    Mammography is the oldest and most popular method in the diagnosis of breast disease and received the special attention as the powerful instrument in early detection of breast cancer. In Korea, the mammography has not been widely used, yet, but nowadays, increasing incidence of breast cancer and good prognosis after early detection and proper treatment need the clinical application of mammography for management of patient with breast disease and for the detection of occult cancer. The technique obtaining the good quality film is essential for improving the diagnostic accuracy of mammography in breast disease and in general, excellent film radiographs of breast can be obtained with proper combination of Kvp, processing, selection of fine grained film, fine focus tube and compression. In present study, radiographic technique was used in which 36-40 Kvp and 200 mAs were derived from a small focus Tungsten Anode tube. Medio-lateral and Cranio-caudad view were taken using Acryl compression device, which was specially designed by authors in order to properly examine the small, dense breasts of Korean women. Non-screen fine grained mammographic films was used and processing was manual.The materials consisted of 150 cases of mammography performed at Yonsei University Medical College, Severance Hospital, since January, 1978. We analyzed the diagnostic accuracy of mammography and mammographic findings in pathologically confirmed 39 cases. The conclusions are as follows: 1. Because women are sensitive to her breast changes, mammography is very useful not only in diagnosis of breast disease and early detection of cancer, but also management of patients with breast symptom and sign. 2. We obtained the relatively good quality film and high diagnostic accuracy with our own method, using conventional Tungsten Anode tube, compression device and hand processing. 3. We also applied specimen radiography in diagnosis of breast disease, which was helpful in verification of the adequacy

  14. Breast compression in mammography: how much is enough?

    Science.gov (United States)

    Poulos, Ann; McLean, Donald; Rickard, Mary; Heard, Robert

    2003-06-01

    The amount of breast compression that is applied during mammography potentially influences image quality and the discomfort experienced. The aim of this study was to determine the relationship between applied compression force, breast thickness, reported discomfort and image quality. Participants were women attending routine breast screening by mammography at BreastScreen New South Wales Central and Eastern Sydney. During the mammographic procedure, an 'extra' craniocaudal (CC) film was taken at a reduced level of compression ranging from 10 to 30 Newtons. Breast thickness measurements were recorded for both the normal and the extra CC film. Details of discomfort experienced, cup size, menstrual status, existing breast pain and breast problems were also recorded. Radiologists were asked to compare the image quality of the normal and manipulated film. The results indicated that 24% of women did not experience a difference in thickness when the compression was reduced. This is an important new finding because the aim of breast compression is to reduce breast thickness. If breast thickness is not reduced when compression force is applied then discomfort is increased with no benefit in image quality. This has implications for mammographic practice when determining how much breast compression is sufficient. Radiologists found a decrease in contrast resolution within the fatty area of the breast between the normal and the extra CC film, confirming a decrease in image quality due to insufficient applied compression force.

  15. Four Principles to Consider Before Advising Women on Screening Mammography

    DEFF Research Database (Denmark)

    Keen, John D; Juhl Jørgensen, Karsten

    2015-01-01

    This article reviews four important screening principles applicable to screening mammography in order to facilitate informed choice. The first principle is that screening may help, hurt, or have no effect. In order to reduce mortality and mastectomy rates, screening must reduce the rate of advanced...... of a screening intervention. Disease-specific mortality is biased due to difficulties in attribution of cause of death and to increased mortality due to overdiagnosis and the resulting overtreatment with radiotherapy and chemotherapy. To enhance participation, the benefit from screening is often presented...... in relative instead of absolute terms. Third, some screening statistics must be interpreted with caution. Increased survival time and the percentage of early-stage tumors at detection sound plausible, but are affected by lead-time and length biases. In addition, analyses that only include women who attend...

  16. A comparison of two different processing chemicals for mammography: Repercussion on dose to patients

    International Nuclear Information System (INIS)

    Sendra-Portero, F.; Ristori-Bogajo, E.; Buch-Tome, P.; Martinez-Morillo, M.; Nava-Baro, E.

    2001-01-01

    The main technical objective of screen-film mammography is to reach the best image quality with the lowest dose to the breast. Sensitometric gradient and speed are factors related to both subjects respectively. For a given choice of film, these factors are affected by processing variables. For this reason, manufacturers have developed different types of films that are recommended for particular processing conditions. The purpose of this work is to compare the variations of both sensitometric characteristics of mammographic screen and film systems induced by two different manufactured chemicals: RPX-Omat EX/LO (Kodak) and G139/G334 (Agfa). A comparison of thirteen mammographic films by means of light sensitometry was performed at different processing conditions: 90s/Kodak, 120s/Kodak, 180s/Kodak, 90s/Agfa, 120s/Agfa and 180s/Agfa. Secondly, 99 combinations of screens and films were evaluated by X-ray sensitometry at 120s/Kodak and 120s/Agfa processing. At light sensitometry, variations in processing time led to different modifications in film speed, depending on the chemicals used. At X-Ray sensitometry, Agfa chemicals induced higher values of sensitivity for almost all combinations, while Kodak chemicals gave higher gradient/speed quotient. The results show that dose to patients in mammography and image contrast are highly dependent on the chemicals selected at medium cycle (120s) processing. (author)

  17. Are benefits and harms in mammography screening given equal attention in scientific articles? A cross-sectional study.

    Science.gov (United States)

    Jørgensen, Karsten Juhl; Klahn, Anders; Gøtzsche, Peter C

    2007-05-30

    The CONSORT statement specifies the need for a balanced presentation of both benefits and harms of medical interventions in trial reports. However, invitations to screening and newspaper articles often emphasize benefits and downplay or omit harms, and it is known that scientific articles can be influenced by conflicts of interest. We wanted to determine if a similar imbalance occurs in scientific articles on mammography screening and if it is related to author affiliation. We searched PubMed in April 2005 for articles on mammography screening that mentioned a benefit or a harm and that were published in 2004 in English. Data extraction was performed by three independent investigators, two unblinded and one blinded for article contents, and author names and affiliation, as appropriate. The extracted data were compared and discrepancies resolved by two investigators in a combined analysis. We defined three groups of authors: (1) authors in specialties unrelated to mammography screening, (2) authors in screening-affiliated specialties (radiology or breast cancer surgery) who were not working with screening, or authors funded by cancer charities, and (3) authors (at least one) working directly with mammography screening programmes. We used a data extraction sheet with 17 items described as important benefits and harms in the 2002 WHO/IARC-report on breast cancer screening. We identified 854 articles, and 143 were eligible for the study. Most were original research. Benefits were mentioned more often than harms (96% vs 62%, P articles mentioned only benefits, whereas seven (5%) mentioned only harms (P articles (24%), but was more often downplayed or rejected in articles that had authors working with screening, (6/15; 40%) compared with authors affiliated by specialty or funding (1/6; 17%), or authors unrelated with screening (1/14; 7%) (P = 0.03). Benefits in terms of reduced breast cancer mortality were mentioned in 109 (76%) articles, and was more often provided as a

  18. A Survey on Physical Factors and Compressed Breast Thickness in Voluntary Mammography Screening Using FFDM System in Malaysia: Preliminary Results

    International Nuclear Information System (INIS)

    Noriah Jamal; Humairah Samad Cheung; Siti Kamariah Che Mohamad; Ellyda Muhamad Nordin

    2013-01-01

    This paper aims at presenting preliminary results of a survey on physical factors, namely tube potential (kV), tube current exposure time product (mAs) and compressed breast thickness (CBT) during voluntary mammography screening using Full-Field Digital Mammography (FFDM) System in Malaysia. Retrospective data were collected from 1128 FFDM images of 282 women from three major ethnic groups (Malay, Chinese and Indian) who underwent voluntary screening mammography at Breast Centre, International Islamic University Malaysia from January to March 2008. Results from the present study were then compared with results from the previous study on Screen-Film Mammography System (SFM) according to the ethnic group for both Cranio-caudal (CC) and Mediol-Lateral (MLO) views. We found that the mean kV for CC view for the three ethnic groups are Malay (28), Chinese (28) and Indian (28), and for MLO view are Malay (29), Chinese (28) and Indian (29). These values are higher than the kV for SFM which were Malay (26), Chinese (27) and Indian (26) for CC and Malay (26), Chinese (27) and Indian (26) for CC and MLO views respectively. The mean mAs for CC and MLO views for FFDM were lower compared to SFM systems. These values were Malay (104), Chinese (108) and Indian (91) for CC views and Malay (106), Chinese (105), and Indian (94) for MLO views for the FFDM system. The values for SFM system are for CC and MLO views were Malay (120), Chinese (106) and Indian (126), and Malay (166), Chinese (132), Indian (183) respectively. The median CBT for CC and MLO views increased by 27 % and 7 % respectively on the FFDM compared to the SFM system. In conclusion, the FFDM operates with higher kV, lower mAs, and higher CBT when compared with SFM system. Median CBT on CC and MLO view with FFDM system are 27 % and 7 % higher respectively compared to the SFM. We are currently collecting data on mean glandular dose with FFDM systems to assess how the change in local mammography practice influences this

  19. CMOS cassette for digital upgrade of film-based mammography systems

    Science.gov (United States)

    Baysal, Mehmet A.; Toker, Emre

    2006-03-01

    While full-field digital mammography (FFDM) technology is gaining clinical acceptance, the overwhelming majority (96%) of the installed base of mammography systems are conventional film-screen (FSM) systems. A high performance, and economical digital cassette based product to conveniently upgrade FSM systems to FFDM would accelerate the adoption of FFDM, and make the clinical and technical advantages of FFDM available to a larger population of women. The planned FFDM cassette is based on our commercial Digital Radiography (DR) cassette for 10 cm x 10 cm field-of-view spot imaging and specimen radiography, utilizing a 150 micron columnar CsI(Tl) scintillator and 48 micron active-pixel CMOS sensor modules. Unlike a Computer Radiography (CR) cassette, which requires an external digitizer, our DR cassette transfers acquired images to a display workstation within approximately 5 seconds of exposure, greatly enhancing patient flow. We will present the physical performance of our prototype system against other FFDM systems in clinical use today, using established objective criteria such as the Modulation Transfer Function (MTF), Detective Quantum Efficiency (DQE), and subjective criteria, such as a contrast-detail (CD-MAM) observer performance study. Driven by the strong demand from the computer industry, CMOS technology is one of the lowest cost, and the most readily accessible technologies available for FFDM today. Recent popular use of CMOS imagers in high-end consumer cameras have also resulted in significant advances in the imaging performance of CMOS sensors against rivaling CCD sensors. This study promises to take advantage of these unique features to develop the first CMOS based FFDM upgrade cassette.

  20. Image Quality in Screening Mammography in Croatia

    International Nuclear Information System (INIS)

    Brnic, Z.; Klasic, B.; Popic-Ramac, J.; Ljevar, A.

    2011-01-01

    Mortality reduction through screening mammography (SMG) is possible only with examination of high image quality (IQ), which should be performed with acceptable patient breast radiation dose (BRD). Besides film processing control, equipment assessment with breast phantom and dosimetry, periodical external mammographic IQ assessment (MIQA) is needed, including image labelling (L), breast positioning (BP), exposure (EX) and artefacts (AR) assessment. The nationwide breast cancer screening program (NBSP) has been introduced in Croatia in 2006, and the MIQA is initiated as the first step in establishing quality assurance/quality control (QA/QC) framework in breast imaging in Croatia. The current study was aimed: (1) to provide objective evidence about the technical MIQ in NBSP in Croatia, (2) to compare MIQ between different types of mammographic units (MUs), (3) to identify the common deficiencies, and (4) to propose corrective activities. Mammograms (MGs) for IQA were collected from a total of 84 MUs which participate in NBSP, which represents 70 % of all MUs nationwide: A total of 420 MG examinations were reviewed. Each MU was requested to submit ''what they consider to be their five best representative MGs, each one performed in one of five consecutive workdays''. Mean age of MG machines was 7.76 years (range 2 - 21), with no difference between four MU types. This very first study of MIQ in Croatia corroborated our intuitive impression of inadequate IQ, staff training and equipment in many MUs nationwide. As MIQ strongly influences BC detection rate, suboptimal QA/QC always carries a risk to compromise the success of NBSP. Deficiencies in SMG, especially in ID and BP reflect different level of competency of radiological staff in Croatia. Differences in MIQ in various MU types are determined by their organization, equipment, education, working habits and motivation. More efforts are needed to train both RTs and radiologists to implement and maintain QA/QC in their

  1. Indicators of image quality and doses in mammography

    International Nuclear Information System (INIS)

    Gaona, E.; Franco E, J.G.; Azorin N, J.; Diaz G, J.A.I.; Arreola, M.

    2007-01-01

    Full text: The purpose of the study was to determine the values of the image quality indicators and their relationship with the dose in mammography of screen-film that they allowed the detection of a bigger number of objects in the images obtained with the mannequin (phantom) authorized of the ACR/FDA. The study was carried out in four mammography services in a period of 12 months. The indicators of the image quality are the half optic density (DOM), contrast (differences of densities), the number of observed objects in the images and the dose for image. The minimum acceptable values by the ACR/FDA are a half optical density of 1.4, contrast of 0.4 and the one numbers minimum of objects observed in the image of the mannequin of mammography of 10 (4 fibers, 3 groups of calcifications and 3 masses), with a maximum dose by image of 3 mGy. The found results are half optical density of 1.9, contrast of 0.56 and the average number of objects observed in the images of 12, with a dose in the interval of 1.6 mGy to 2.4 mGy. The doses were measured by thermoluminescent dosimetry and ionization chamber. Once carried out the analysis of the tendencies of the indicators of image quality and their distributions is found that for a p < 0.05, the bigger number of objects observed in the images is in the interval from 1.8 to 1.9 of DOM. When comparing both mammography system, the system screen-film has a lower variability in the distribution of objects associated to a DOM. (Author)

  2. The impact of digital mammography on screening a young cohort of women for breast cancer in an urban specialist breast unit

    International Nuclear Information System (INIS)

    Perry, Nicholas M.; Milner, S.E.; Mokbel, K.; Patani, N.; Pinker, K.; Allgood, P.C.; Duffy, S.W.

    2011-01-01

    To compare the diagnostic performance of full-field digital mammography (FFDM) with screen-film mammography (SFM) in a corporate screening programme including younger women. Data were available on 14,946 screening episodes, 5010 FFDM and 9936 SFM. Formal analysis was by logistic regression, adjusting for age and calendar year. FFDM is compared with SFM with reference to cancer detection rates, cancers presenting as clustering microcalcifications, recall rates and PPV of recall. Overall detection rates were 6.4 cancers per thousand screens for FFDM and 2.8 per thousand for SFM (p < 0.001). In women aged 50+ cancer detection was significantly higher for FFDM at 8.6 per thousand vs. 4.0 per thousand, (p = 0.002). In women <50, cancer detection was also significantly higher for FFDM at 4.3 per thousand vs. 1.4 per thousand, (p = 0.02). Cancers detected as clustering microcalcifications increased from 0.4 per thousand with SFM to 2.0 per thousand with FFDM. Rates of assessment recall were higher for FFDM (7.3% vs. 5.0%, p < 0.001). FFDM provided a higher PPV for assessment recall, (32 cancers/364 recalls, 8.8%) than SFM, (28 cancers/493 recalls, 5.7%). Cancer detection rates were significantly higher for FFDM than for SFM, especially for women <50, and cancers detected as clustering microcalcifications. (orig.)

  3. The impact of digital mammography on screening a young cohort of women for breast cancer in an urban specialist breast unit

    Energy Technology Data Exchange (ETDEWEB)

    Perry, Nicholas M.; Milner, S.E.; Mokbel, K. [The Princess Grace Hospital, The London Breast Institute, London (United Kingdom); Patani, N. [St. George' s University of London, Department of Breast Surgery, London (United Kingdom); Pinker, K. [Medical University Vienna, Department of Radiology, Division of Molecular and Gender Imaging, Vienna (Austria); Allgood, P.C.; Duffy, S.W. [Queen Mary University of London, Cancer Research UK Centre for Epidemiology, Mathematics and Statistics, Wolfson Institute of Preventive Medicine, Barts and The London School of Medicine and Dentistry, London (United Kingdom)

    2011-04-15

    To compare the diagnostic performance of full-field digital mammography (FFDM) with screen-film mammography (SFM) in a corporate screening programme including younger women. Data were available on 14,946 screening episodes, 5010 FFDM and 9936 SFM. Formal analysis was by logistic regression, adjusting for age and calendar year. FFDM is compared with SFM with reference to cancer detection rates, cancers presenting as clustering microcalcifications, recall rates and PPV of recall. Overall detection rates were 6.4 cancers per thousand screens for FFDM and 2.8 per thousand for SFM (p < 0.001). In women aged 50+ cancer detection was significantly higher for FFDM at 8.6 per thousand vs. 4.0 per thousand, (p = 0.002). In women <50, cancer detection was also significantly higher for FFDM at 4.3 per thousand vs. 1.4 per thousand, (p = 0.02). Cancers detected as clustering microcalcifications increased from 0.4 per thousand with SFM to 2.0 per thousand with FFDM. Rates of assessment recall were higher for FFDM (7.3% vs. 5.0%, p < 0.001). FFDM provided a higher PPV for assessment recall, (32 cancers/364 recalls, 8.8%) than SFM, (28 cancers/493 recalls, 5.7%). Cancer detection rates were significantly higher for FFDM than for SFM, especially for women <50, and cancers detected as clustering microcalcifications. (orig.)

  4. The impact of digital mammography on screening a young cohort of women for breast cancer in an urban specialist breast unit.

    Science.gov (United States)

    Perry, Nicholas M; Patani, N; Milner, S E; Pinker, K; Mokbel, K; Allgood, P C; Duffy, S W

    2011-04-01

    To compare the diagnostic performance of full-field digital mammography (FFDM) with screen-film mammography (SFM) in a corporate screening programme including younger women. Data were available on 14,946 screening episodes, 5010 FFDM and 9936 SFM. Formal analysis was by logistic regression, adjusting for age and calendar year. FFDM is compared with SFM with reference to cancer detection rates, cancers presenting as clustering microcalcifications, recall rates and PPV of recall. Overall detection rates were 6.4 cancers per thousand screens for FFDM and 2.8 per thousand for SFM (p < 0.001). In women aged 50+ cancer detection was significantly higher for FFDM at 8.6 per thousand vs. 4.0 per thousand, (p = 0.002). In women <50, cancer detection was also significantly higher for FFDM at 4.3 per thousand vs. 1.4 per thousand, (p = 0.02). Cancers detected as clustering microcalcifications increased from 0.4 per thousand with SFM to 2.0 per thousand with FFDM. Rates of assessment recall were higher for FFDM (7.3% vs. 5.0%, p < 0.001). FFDM provided a higher PPV for assessment recall, (32 cancers/364 recalls, 8.8%) than SFM, (28 cancers/493 recalls, 5.7%). Cancer detection rates were significantly higher for FFDM than for SFM, especially for women <50, and cancers detected as clustering microcalcifications.

  5. Cost-Effectiveness of Breast Cancer Screening in Turkey, a Developing Country: Results from Bahçeşehir Mammography Screening Project.

    Science.gov (United States)

    Özmen, Vahit; Gürdal, Sibel Ö; Cabioğlu, Neslihan; Özcinar, Beyza; Özaydın, A Nilüfer; Kayhan, Arda; Arıbal, Erkin; Sahin, Cennet; Saip, Pınar; Alagöz, Oğuzhan

    2017-07-01

    We used the results from the first three screening rounds of Bahcesehir Mammography Screening Project (BMSP), a 10-year (2009-2019) and the first organized population-based screening program implemented in a county of Istanbul, Turkey, to assess the potential cost-effectiveness of a population-based mammography screening program in Turkey. Two screening strategies were compared: BMSP (includes three biennial screens for women between 40-69) and Turkish National Breast Cancer Registry Program (TNBCRP) which includes no organized population-based screening. Costs were estimated using direct data from the BMSP project and the reimbursement rates of Turkish Social Security Administration. The life-years saved by BMSP were estimated using the stage distribution observed with BMSP and TNBCRP. A total of 67 women (out of 7234 screened women) were diagnosed with breast cancer in BMSP. The stage distribution for AJCC stages O, I, II, III, IV was 19.4%, 50.8%, 20.9%, 7.5%, 1.5% and 4.9%, 26.6%, 44.9%, 20.8%, 2.8% with BMSP and TNBCRP, respectively. The BMSP program is expected to save 279.46 life years over TNBCRP with an additional cost of $677.171, which implies an incremental cost-effectiveness ratio (ICER) of $2.423 per saved life year. Since the ICER is smaller than the Gross Demostic Product (GDP) per capita in Turkey ($10.515 in 2014), BMSP program is highly cost-effective and remains cost-effective in the sensitivity analysis. Mammography screening may change the stage distribution of breast cancer in Turkey. Furthermore, an organized population-based screening program may be cost-effective in Turkey and in other developing countries. More research is needed to better estimate life-years saved with screening and further validate the findings of our study.

  6. Measurement of the radiation dose and assessment of the risk in mammography screening for early detection of cancer of the breast, in Israel

    International Nuclear Information System (INIS)

    Broisman, A.; Schlesinger, T.; Alfassi, Z. B.

    2011-01-01

    The mean glandular doses to samples of women attending for mammographic screening are measured routinely at screening centres in Israel. As at present, no detailed and systematic data have been collected regarding the average glandular dose in mammography screening procedures carried out in Israel for the last 20 y. Especially data are lacking related to the glandular dose (GD) involved in mammography with the new digital mammography systems. In this work, partial results of the measurements are presented to asses the radiation dose to the breast and to the glandular tissue within the Israeli national mammography programme updated to year 2009. (authors)

  7. Determining the spatial heterogeneity underlying racial and ethnic differences in timely mammography screening

    Directory of Open Access Journals (Sweden)

    Joseph Gibbons

    2016-11-01

    Full Text Available Abstract Background The leading cause of cancer death for women worldwide continues to be breast cancer. Early detection through timely mammography has been recognized to increase the probability of survival. While mammography rates have risen for many women in recent years, disparities in screening along racial/ethnic lines persist across nations. In this paper, we argue that the role of local context, as identified through spatial heterogeneity, is an unexplored dynamic which explains some of the gaps in mammography utilization by race/ethnicity. Methods We apply geographically weighted regression methods to responses from the 2008 Public Health Corporations’ Southeastern Household Health Survey, to examine the spatial heterogeneity in mammograms in the Philadelphia metropolitan area. Results We find first aspatially that minority identity, in fact, increases the odds of a timely mammogram: 74% for non-Hispanic Blacks and 80% for Hispanic/Latinas. However, the geographically weighted regression confirms the relation of race/ethnicity to mammograms varies by space. Notably, the coefficients for Hispanic/Latinas are only significant in portions of the region. In other words, the increased odds of a timely mammography we found are not constant spatially. Other key variables that are known to influence timely screening, such as the source of healthcare and social capital, measured as community connection, also vary by space. Conclusions These results have ramifications globally, demonstrating that the influence of individual characteristics which motivate, or inhibit, cancer screening may not be constant across space. This inconsistency calls for healthcare practitioners and outreach services to be mindful of the local context in their planning and resource allocation efforts.

  8. Ultrasonic mammography

    International Nuclear Information System (INIS)

    Hueneke, B.

    1982-01-01

    608 women are examined by means of ultrasonic mammography during the period of 1 year. 432 patients were examined with the compound method with the U.I. Octoson, a water tank scanner, and 176 patients with the real time method with a directly connected linear-array-scanner. The following results were obtained at the end of the examination period: In the ultrasonic and also in the X-ray mammogram tumour diameters can be determined with an error rate of +- 30%. In the diagnosing of carcinomas, a significant dependence of the exactness on the sice of the tumour is found for the combination of the five methods tested (clinical examination, X-ray mammography, ultrasonic mammography, thermography, cytology). Classifying the individual methods with regard to their exactness, X-ray mammography ranks in front of ultrasonic mammography. Mastopathic changes in the breast can be screened by means of ultrasonic mammography. The structure of the changes can be determined more exactly than with an X-ray picture which is due to the possibility of differentiating solid and cystic structures. In diagnosing fibro-adenomas and establishing diagnoses on young women with dense gland bodies, ultrasonic mammography is superior to radiology both in the ability of screening a finding of a fibro-adenoma (US=88%, X-ray=75%) and in the possibility of classifying it as ''more benign than malignant''. (orig./MG) [de

  9. Overdiagnosis in organised mammography screening in Denmark. A comparative study

    DEFF Research Database (Denmark)

    Jørgensen, Karsten J; Zahl, Per-Henrik; Gøtzsche, Peter C

    2009-01-01

    % of the Danish population has been offered organised mammography screening over a long time-period. METHODS: We collected incidence rates of carcinoma in situ and invasive breast cancer in areas with and without screening over 13 years with screening (1991-2003), and 20 years before its introduction (1971...... an overdiagnosis of 35% when we compared unadjusted incidence rates for the screened and non-screened areas, but after compensating for a small decline in incidence in older, previously screened women. Our adjusted Poisson regression analysis indicated a relative risk of 1.40 (95% CI: 1.35-1.45) for the whole...... screening period, and a potential compensatory drop in older women of 0.90 (95% CI: 0.88-0.96), yielding an overdiagnosis of 33%, which we consider the most reliable estimate. The drop in previously screened women was only present in one of the two screened regions and was small in absolute numbers...

  10. Reduction in advanced breast cancer after introduction of a mammography screening program in Tyrol/Austria.

    Science.gov (United States)

    Oberaigner, W; Geiger-Gritsch, Sabine; Edlinger, M; Daniaux, M; Knapp, R; Hubalek, M; Siebert, U; Marth, C; Buchberger, W

    2017-06-01

    We analysed all female breast cancer (BC) cases in Tyrol/Austria regarding the shift in cancer characteristics, especially the shift in advanced BC, for the group exposed to screening as compared to the group unexposed to screening. The analysis was based on all BC cases diagnosed in women aged 40-69 years, resident in Tyrol, and diagnosed between 2009 and 2013. The data were linked to the Tyrolean mammography screening programme database to classify BC cases as "exposed to screening" or "unexposed to screening". Age-adjusted relative risks (RR) were estimated by relating the exposed to the unexposed group. In a total of about 145,000 women aged 40-69 years living in Tyrol during the study period, 1475 invasive BC cases were registered. We estimated an age-adjusted relative risk (RR) for tumour size ≥ 21 mm of 0.72 (95% confidence interval (CI) 0.60 to 0.86), for metastatic BC of 0.27 (95% CI 0.17 to 0.46) and for advanced BC of 0.83 (95% CI 0.71 to 0.96), each comparing those exposed to those unexposed to screening, respectively. In our population-based registry analysis we observed that participation in the mammography screening programme in Tyrol is associated with a 28% decrease in risk for BC cases with tumour size ≥ 21 mm and a 17% decrease in risk for advanced BC. We therefore expect the Tyrolean mammography programme to show a reduction in BC mortality. Copyright © 2017 Elsevier Ltd. All rights reserved.

  11. Population-based mammography screening below age 50: Balancing radiation-induced vs prevented breast cancer deaths

    NARCIS (Netherlands)

    R. de Gelder (Rianne); G. Draisma (Gerrit); E.A.M. Heijnsdijk (Eveline); H.J. de Koning (Harry)

    2011-01-01

    textabstractIntroduction:Exposure to ionizing radiation at mammography screening may cause breast cancer. Because the radiation risk increases with lower exposure age, advancing the lower age limit may affect the balance between screening benefits and risks. The present study explores the

  12. Health-related lifestyle factors and mammography screening attendance in a Swedish cohort study.

    Science.gov (United States)

    Lagerlund, Magdalena; Drake, Isabel; Wirfält, Elisabet; Sontrop, Jessica M; Zackrisson, Sophia

    2015-01-01

    To determine whether health-related lifestyle factors are associated with attendance at a population-based invitational mammography screening program in southern Sweden, data on health-related lifestyle factors (smoking, alcohol use, physical activity, BMI, diet, self-rated health, and stress) were obtained from the Malmö Diet and Cancer Study and linked to the Malmö mammography register (Sweden, 1992-2009). Women (n=11 409) who were free from breast cancer at study entry were included in the cohort, and mammography attendance was followed from cohort entry to 31 December 2009. Generalized estimating equations were used to account for repeated measures within patients. Adjusted odds ratios (OR) and 95% confidence intervals (CI) are reported. Nonattendance occurred in 8% of the 69 746 screening opportunities that were observed. Nonattendance was more common among women who were current or former smokers [OR=1.60 (1.45-1.76) and OR=1.15 (1.05-1.28)], had not used alcohol in the past year [OR=1.55 (1.32-1.83)], were less physically active outside of work [OR=1.10 (1.00-1.20)], had high physical activity at work (OR=1.13, 95% CI: 1.00-1.28), were vegetarians or vegans [OR=1.49 (1.11-1.99)], had not used dietary supplements [OR=1.11 (1.01-1.21)], had poor self-rated health [OR=1.24 (1.14-1.36)], and were experiencing greater stress [OR=1.25 (1.14-1.36)]. In this cohort, nonattendance was associated with smoking, alcohol abstinence, physical activity, poor self-rated health, stress, and following a vegetarian/vegan diet. These findings generally support the notion that women with less healthy lifestyles are less likely to engage in mammography screening.

  13. National Performance Benchmarks for Modern Screening Digital Mammography: Update from the Breast Cancer Surveillance Consortium.

    Science.gov (United States)

    Lehman, Constance D; Arao, Robert F; Sprague, Brian L; Lee, Janie M; Buist, Diana S M; Kerlikowske, Karla; Henderson, Louise M; Onega, Tracy; Tosteson, Anna N A; Rauscher, Garth H; Miglioretti, Diana L

    2017-04-01

    Purpose To establish performance benchmarks for modern screening digital mammography and assess performance trends over time in U.S. community practice. Materials and Methods This HIPAA-compliant, institutional review board-approved study measured the performance of digital screening mammography interpreted by 359 radiologists across 95 facilities in six Breast Cancer Surveillance Consortium (BCSC) registries. The study included 1 682 504 digital screening mammograms performed between 2007 and 2013 in 792 808 women. Performance measures were calculated according to the American College of Radiology Breast Imaging Reporting and Data System, 5th edition, and were compared with published benchmarks by the BCSC, the National Mammography Database, and performance recommendations by expert opinion. Benchmarks were derived from the distribution of performance metrics across radiologists and were presented as 50th (median), 10th, 25th, 75th, and 90th percentiles, with graphic presentations using smoothed curves. Results Mean screening performance measures were as follows: abnormal interpretation rate (AIR), 11.6 (95% confidence interval [CI]: 11.5, 11.6); cancers detected per 1000 screens, or cancer detection rate (CDR), 5.1 (95% CI: 5.0, 5.2); sensitivity, 86.9% (95% CI: 86.3%, 87.6%); specificity, 88.9% (95% CI: 88.8%, 88.9%); false-negative rate per 1000 screens, 0.8 (95% CI: 0.7, 0.8); positive predictive value (PPV) 1, 4.4% (95% CI: 4.3%, 4.5%); PPV2, 25.6% (95% CI: 25.1%, 26.1%); PPV3, 28.6% (95% CI: 28.0%, 29.3%); cancers stage 0 or 1, 76.9%; minimal cancers, 57.7%; and node-negative invasive cancers, 79.4%. Recommended CDRs were achieved by 92.1% of radiologists in community practice, and 97.1% achieved recommended ranges for sensitivity. Only 59.0% of radiologists achieved recommended AIRs, and only 63.0% achieved recommended levels of specificity. Conclusion The majority of radiologists in the BCSC surpass cancer detection recommendations for screening

  14. Use of prior mammograms in the transition to digital mammography: A performance and cost analysis

    International Nuclear Information System (INIS)

    Taylor-Phillips, S.; Wallis, M.G.; Duncan, A.; Gale, A.G.

    2012-01-01

    Breast screening in Europe is gradually changing from film to digital imaging and reporting of cases. In the transition period prior mammograms (from the preceding screening round) are films thereby potentially causing difficulties in comparison to current digital mammograms. To examine this breast screening performance was measured at a digital mammography workstation with prior mammograms displayed in different formats, and the associated costs calculated. 160 selected difficult cases (41% malignant) were read by eight UK qualified mammography readers in three conditions: with film prior mammograms; with digitised prior mammograms; or without prior mammograms. Lesion location and probability of malignancy were recorded, alongside a decision of whether to recall each case for further tests. JAFROC analysis showed a difference between conditions (p = .006); performance with prior mammograms in either film or digitised formats was superior to that without prior mammograms (p < .05). There was no difference in the performance when the prior mammograms were presented in film or digitised form. The number of benign or normal cases recalled was 26% higher without prior mammograms than with digitised or film prior mammograms (p < .05). This would correspond to an increase in recall rate at the study hospital from 4.3% to 5.5% with no associated increase in cancer detection rate. The cost of this increase was estimated to be £11,581 (€13,666) per 10,000 women screened, which is higher than the cost of digitised (£11,114/€13,115), or film display (£6451/€7612) of the prior mammograms. It is recommended that, where available, prior mammograms are used in the transition to digital breast screening.

  15. Image Quality and Patient Dose Optimisation in Mammography in Slovakia

    International Nuclear Information System (INIS)

    Horvathova, M.; Nikodemova, D.; Prikazska, M.

    2003-01-01

    Breast cancer represents also in Slovakia the greatest cancer risk for women, with great incidence and mortality. Conventional film-screen mammography is still the primary breast imaging modality with increasing number of mammography units and mammography examinations. From the radiation protection point of view achievement of good practice in mammography department by implementation of quality assurance play an important role for reduction of patients doses. Introduction of QA needs trained and experienced staff and requires close collaboration between radiologists, medical physicist and radiographers. At the beginning of nineties at the Institute of Preventive and Clinical Medicine we started with a survey of mean glandular doses at 15 existing mammography units in the country. On the basis of a questionnaire in the year 1991 were performed 10 488 mammography examinations, where due to out of date mammography units the mean glandular dose reached more as 3 mGy. In the following years the claim to the modern mammography units kept growing and in the year 1999 the total number of 63 mammography units were operating in Slovakia providing about 101 471 mammography examinations. According to the alarming increase of the number of mammography examinations it is absolutely necessary to work out criteria and principles for Quality Control at mammography workplaces in our country and make it obligatory for the staff of all mammography units. Summarising the CRP results it can be stated that they: 1) Initiated the suggestion of unified QA/QC criteria in mammography and the urgent need to implement them into the national program of radiology image quality improvement; 2) Remitted on unhomogenity not only in the equipment outfit but also in the procedure of evaluation of the measured parameters and imaging quality; 3) Revealed the shortcomings in the everyday practice of mammography units which can be removed only by comprehensive by training of personal in imaging radiology

  16. Relation between breast cancer mortality and screening effectiveness: systematic review of the mammography trials

    DEFF Research Database (Denmark)

    Gøtzsche, Peter C

    2011-01-01

    The mammography screening trials have shown varying results. This could be because screening was better in some trials than in others at advancing the time of diagnosis. If so, more cancers would be identified in such trials relative to the control group, and fewer of the cancers would have reach...

  17. Mammography

    Science.gov (United States)

    ... breast cancer Whether there is any harm from breast cancer screening, such as side effects from testing or overtreatment of cancer when it's discovered Mammography is performed to screen women to detect early breast cancer when it is ...

  18. The results of a quality-control programme in mammography

    International Nuclear Information System (INIS)

    Ramsdale, M.L.; Hiles, P.A.

    1989-01-01

    With the introduction of a breast screening programme in the UK, quality assurance in mammography is of paramount importance in assuring optimum imaging performance with low dose. Quality control checks are an essential part of the quality-assurance system. A quality-control programme at a breast screening clinic is described. Daily checks include film sensitometry for X-ray processor control and radiography of a lucite phantom to monitor the consistency of the X-ray machine automatic exposure control. Weekly checks include additional measurements on the performance of the automatic exposure control for different breast thickness and an overall assessment of image quality using a prototype mammography test phantom. The test phantom measures low-contrast sensitivity, high-contrast resolution and small-detail visibility. The results of the quality-control programme are presented with particular attention paid to tolerances and limiting values. (author)

  19. Mammography - importance, possibilities, current screening situation of the breast cancer and further expansion possibilities

    International Nuclear Information System (INIS)

    Bella, V.

    2006-01-01

    Breast cancer still remains the most frequent cancer in women population. Incidence of breast cancer is increasing, but mortality is decreasing. The most important for decreasing of breast cancer mortality is early diagnostic, especially screening. Screening is a form of secondary prevention. Although many screening studies have shown that mammography decreases of the breast cancer death, there are still many controversies. The published recommendations for the breast screening are sometimes very different. (author)

  20. Value of mammography screening in women under age 50 years

    International Nuclear Information System (INIS)

    Eddy, D.M.; Hasselblad, V.; McGivney, W.; Hendee, W.

    1988-01-01

    Two quantitative methods, Confidence Profiles and CAN*TROL, are used to analyze evidence and estimate the health and economic consequences of adding annual mammography to annual breast physical examinations in asymptomatic women aged 40 to 49 years who are at average risk for breast cancer. Such women have about a 128 in 10,000 chance of having breast cancer in the next ten years and about an 82 in 10,000 chance of dying of such a cancer. Adding annual mammograms to annual breast physical examinations each year during that age decade would reduce the probability of death to about 60 in 10,000, a reduction of about 26%. Screening would increase the expected lifetime of a woman destined to get breast cancer between ages 40 and 49 years by about 3.5 years. Ten years of screening with mammography in that age decade carries a risk of radiation-induced cancer of about one in 25,000 and a risk of a surgery recommendation for a lesion that is not cancer of about one in ten. If 25% of the women in this age group in the United States were screened every year, breast cancer mortality in the year 2000 would be decreased by about 373 deaths. In 1984 dollars, the cost of screening, workups, and continuing care in the year 2000 would be about $408 million. Treatment costs would be decreased by about $6 million, leaving a net increase in costs in the year of 2000 of approximately $402 million (1984 dollars)

  1. Computer assisted visualization of digital mammography images

    International Nuclear Information System (INIS)

    Funke, M.; Breiter, N.; Grabbe, E.; Netsch, T.; Biehl, M.; Peitgen, H.O.

    1999-01-01

    Purpose: In a clinical study, the feasibility of using a mammography workstation for the display and interpretation of digital mammography images was evaluated and the results were compared with the corresponding laser film hard copies. Materials and Methods: Digital phosphorous plate radiographs of the entire breast were obtained in 30 patients using a direct magnification mammography system. The images were displayed for interpretation on the computer monitor of a dedicated mammography workstation and also presented as laser film hard copies on a film view box for comparison. The images were evaluted with respect to the image handling, the image quality and the visualization of relevant structures by 3 readers. Results: Handling and contrast of the monitor displayed images were found to be superior compared with the film hard copies. Image noise was found in some cases but did not compromise the interpretation of the monitor images. The visualization of relevant structures was equal with both modalities. Altogether, image interpretation with the mammography workstation was considered to be easy, quick and confident. Conclusions: Computer-assisted visualization and interpretation of digital mammography images using a dedicated workstation can be performed with sufficiently high diagnostic accuracy. (orig.) [de

  2. Computer-aided diagnostics of screening mammography using content-based image retrieval

    Science.gov (United States)

    Deserno, Thomas M.; Soiron, Michael; de Oliveira, Júlia E. E.; de A. Araújo, Arnaldo

    2012-03-01

    Breast cancer is one of the main causes of death among women in occidental countries. In the last years, screening mammography has been established worldwide for early detection of breast cancer, and computer-aided diagnostics (CAD) is being developed to assist physicians reading mammograms. A promising method for CAD is content-based image retrieval (CBIR). Recently, we have developed a classification scheme of suspicious tissue pattern based on the support vector machine (SVM). In this paper, we continue moving towards automatic CAD of screening mammography. The experiments are based on in total 10,509 radiographs that have been collected from different sources. From this, 3,375 images are provided with one and 430 radiographs with more than one chain code annotation of cancerous regions. In different experiments, this data is divided into 12 and 20 classes, distinguishing between four categories of tissue density, three categories of pathology and in the 20 class problem two categories of different types of lesions. Balancing the number of images in each class yields 233 and 45 images remaining in each of the 12 and 20 classes, respectively. Using a two-dimensional principal component analysis, features are extracted from small patches of 128 x 128 pixels and classified by means of a SVM. Overall, the accuracy of the raw classification was 61.6 % and 52.1 % for the 12 and the 20 class problem, respectively. The confusion matrices are assessed for detailed analysis. Furthermore, an implementation of a SVM-based CBIR system for CADx in screening mammography is presented. In conclusion, with a smarter patch extraction, the CBIR approach might reach precision rates that are helpful for the physicians. This, however, needs more comprehensive evaluation on clinical data.

  3. Pain and discomfort during mammography

    DEFF Research Database (Denmark)

    Aro, A R; Absetz-Ylöstalo, P; Eerola, T

    1996-01-01

    was the most powerful factor explaining pain and discomfort among women with earlier mammography. However, it had no effect among women without earlier mammography, for whom screening-related nervousness and perceptions of staff were crucial. Suggested interventions include better information before screening......The aim of this prospective study was to investigate associations of mammography pain and discomfort with sociodemographics, personal history and psychological and situational factors. Subjects were women with a negative screening finding (n = 883) from a random sample of 50-year-old Finnish women...... attending their first breast cancer screening. Questionnaires were sent 1 month before the screening invitation and 2 months after screening. Sixty-one per cent reported painful and 59% uncomfortable mammograms (4% severely). Linear regression analyses showed that anticipation of pain and discomfort...

  4. Results of breast cancer screening with mammography carried out in Koriyama City over a three-year period (2001- 2003)

    International Nuclear Information System (INIS)

    Yoshida, Hatsuo; Iwanami, Hiroshi; Urazumi, Koujirou

    2005-01-01

    In 2001, biennial breast cancer screening with mammography was started in Koriyama City for women aged 40 years or over. The screening involved both physical examination, including inspection and palpation, and mammography performed separately. Women with abnormal findings on physical examination were recalled, while those without such findings underwent medio-lateral oblique projection mammography. There were a total of 15,246 responders during the three-year period 2001 -2003. The recall rate after physical examination was 3.1% and breast cancer was detected in 25 women (0.16%). For 13,310 women who underwent mammography, the recall rate was 3.9% and 25 breast cancers (0.18%) were detected. Combining these two subgroups, the overall recall rate was 6.5%, the cancer detection rate was 0.33%, the ratio of cancers detected among women who were asked to attend for a recall examination was 5.0%, and the ratio of cancers detected among women who underwent a recall examination was 5.6%. Early cancers detected at Stage 0 or 1 comprised 32 (64%), and lymph node metastasis was positive in 12 women (24%). Thus the results of our screening reached satisfactory levels in terms of the five items proposed by the Breast Imaging Reporting and Data System of the American Radiology Association. In order to further increase the quality of breast cancer screening, proper determination of categories at mammography reading and standardization of recall examination techniques, including histopathological study, are required. (author)

  5. Performance characteristics of digital vs film screen mammography in community practice.

    Science.gov (United States)

    Dabbous, Firas; Dolecek, Therese A; Friedewald, Sarah M; Tossas-Milligan, Katherine Y; Macarol, Tere; Summerfelt, Wm Thomas; Rauscher, Garth H

    2018-05-01

    We compared the performance characteristics of 297 629 full field digital (FFDM) and 416 791 screen film mammograms (SFM). Sensitivity increased with age, decreased with breast density, and was lower for more aggressive and lobular tumors. While sensitivity did not differ significantly by modality, specificity was generally 1%-2% points higher for FFDM than for SFM across age and breast density categories. The lower recall rate for FFDM vs SFM in our study may partially explain performance differences by modality. In this large health care organization, modest gains in performance were achieved with the introduction of FFDM as a replacement for SFM. © 2017 Wiley Periodicals, Inc.

  6. Patient dose and risk in mammography

    International Nuclear Information System (INIS)

    Law, J.

    1991-01-01

    Patient dose in mammography is estimated by two methods compared and giving agreement. A mean tissue dose of about 1 mGy per film is found for a breast of 4.5 cm compressed thickness. Variables affecting dose are then considered quantitatively, including compressed breast thickness, tube potential, grids, magnification and beam collimation. The variables having the greatest effect are breast thickness and magnification. The dose estimates are combined with existing data on breast cancer induction to predict the risk of carcinogenesis in a breast screening programme. For example, in a screening centre performing 15 000 examinations per year, only one induced cancer is predicted in about 7 years of screening under average UK conditions of age and breast thickness. (author)

  7. Trends in breast cancer mortality in Sweden before and after implementation of mammography screening.

    Directory of Open Access Journals (Sweden)

    Jari Haukka

    Full Text Available Incidence-based mortality modelling comparing the risk of breast cancer death in screened and unscreened women in nine Swedish counties has suggested a 39% risk reduction in women 40 to 69 years old after introduction of mammography screening in the 1980s and 1990s.We evaluated changes in breast cancer mortality in the same nine Swedish counties using a model approach based on official Swedish breast cancer mortality statistics, robust to effects of over-diagnosis and treatment changes. Using mortality data from the NordCan database from 1974 until 2003, we estimated the change in breast cancer mortality before and after introduction of mammography screening in at least the 13 years that followed screening start.Breast mortality decreased by 16% (95% CI: 9 to 22% in women 40 to 69, and by 11% (95% CI: 2 to 20% in women 40 to 79 years of age.Without individual data it is impossible to completely separate the effects of improved treatment and health service organisation from that of screening, which would bias our results in favour of screening. There will also be some contamination of post-screening mortality from breast cancer diagnosed prior to screening, beyond our attempts to adjust for delayed benefit. This would bias against screening. However, our estimates from publicly available data suggest considerably lower benefits than estimates based on comparison of screened versus non-screened women.

  8. st Tomosynthesis Plus Full Field Digital Mammography or Full Field Digital Mammography Alone in the Screening Environment

    Directory of Open Access Journals (Sweden)

    Stamatia Destounis

    2014-01-01

    Full Text Available Objectives: Initial review of patients undergoing screening mammography imaged with a combination of digital breast tomosynthesis (DBT plus full field digital mammography (FFDM compared with FFDM alone. Materials and Methods: From June 2011 to December 2011, all patients presenting for routine screening mammography were offered a combination DBT plus FFDM exam. Under institutional review board approval, we reviewed 524 patients who opted for combination DBT plus FFDM and selected a sample group of 524 FFDM screening exams from the same time period for a comparative analysis. The χ2 (Chi-square test was used to compare recall rates, breast density, personal history of breast cancer, and family history of breast cancer between the two groups. Results: Recall rate for FFDM, 11.45%, was significantly higher (P < 0001 than in the combination DBT plus FFDM group (4.20%. The biopsy rate in the FFDM group was 2.29% (12/524, with a cancer detection rate of 0.38% (2/524, or 3.8 per 1000 and positive predictive value (PPV of 16.7% (2/12. The biopsy rate for the DBT plus FFDM group was 1.14% (n = 6/524, with a cancer detection rate 0.57% (n = 3/524, or 5.7 per 1000 and PPV of 50.0% (n = 3/6. Personal history of breast cancer in the FFDM group was significantly lower (P < 0.0001 than in the combination DBT plus FFDM group; 2.5% and 5.7%, respectively. A significant difference in family history of breast cancer (P < 0.0001 was found, with a higher rate in the combination DBT plus FFDM group (36.0% vs. 53.8%. There was a significant difference between the combination DBT plus FFDM group and FFDM alone group, when comparing breast density (P < 0.0147, 61.64% vs. 54.20% dense breasts, respectively with a higher rate of dense breasts in the DBT plus FFDM group. In follow-up, one cancer was detected within one year of normal screening mammogram in the combination DBT plus FFDM group. Conclusion: Our initial experience found the recall rate in the combination DBT

  9. Survey of breast cancer screening by mammography. Results of a questionnaire sent to local self-governing bodies

    International Nuclear Information System (INIS)

    Ishibashi, Tadashi; Yamada, Takayuki; Sai, Masahiro; Ohnuki, Koji; Uematsu, Takayoshi; Matsumoto, Masao; Uchiyama, Nachiko; Hara, Takeshi

    2009-01-01

    In order to grasp the current status of breast cancer screening in Japan, a questionnaire was distributed to all local self-governing bodies (LSGB). The results indicated that breast cancer screening with mammography was performed by 97.9% of LSGB. Breast cancer screening was started for women aged less than 40 years at 11.9% of the LSGB, and from 40 years of age at 86.8%. Breast cancer screening for women aged 30-39 years was performed at 51.2% of the LSGB. The proportions of studies involving palpation, mammography, and ultrasonography (US) were 34.0%, 24.5%, and 41.6%, respectively. The coverage of screening invitations between April 2006 and March 2007 was grasped at 94.7% of LSGB. At 23.2%, the coverage was less than 10%, and at 33.8% was 10-19.9%. At 7.1%, the coverage was 50% or more. The national average for coverage was 10%, and was especially low in large cities. The recall rate for LSBG between April 2006 and March 2007 was 85.2%. At 22.4% of the LSBG, recall rates were less than 5%, and at 15.6% the recall rates were 50% or more. Screening mammography for women aged 30-39 years needs to be examined in the future. When recall rates exceed 20%, it is necessary to re-examine the accuracy management of breast cancer screening. (author)

  10. Advanced Breast Cancer as Indicator of Quality Mammography

    International Nuclear Information System (INIS)

    Gaona, Enrique

    2003-01-01

    Breast cancer is the most frequently diagnosed cancer and is the second leading cause of cancer death among women in the Mexican Republic. Mammography is the more important screening tool for detecting early breast cancer. Screening mammography involves taking x-rays from two views from each breast, typically from above (cranial-caudal view, CC) and from an oblique or angled view (mediolateral-oblique, MLO). The purpose of this study was to carry out an exploratory survey of the issue of patients with advanced breast cancer who have had a screening mammography. A general result of the survey is that 22.5% of all patients (102) with advanced breast cancer that participated in the study had previous screening mammography. But we should consider that 10% of breast cancers are not detected by mammography. Only 70% of the family doctors prescribed a diagnostic mammography when the first symptoms were diagnosed

  11. A new test phantom with different breast tissue compositions for image quality assessment in conventional and digital mammography

    International Nuclear Information System (INIS)

    Pachoud, Marc; Lepori, D; Valley, Jean-Francois; Verdun, Francis R

    2004-01-01

    Our objective is to describe a new test phantom that permits the objective assessment of image quality in conventional and digital mammography for different types of breast tissue. A test phantom, designed to represent a compressed breast, was made from tissue equivalent materials. Three separate regions, with different breast tissue compositions, are used to evaluate low and high contrast resolution, spatial resolution and image noise. The phantom was imaged over a range of kV using a Contour 2000 (Bennett) mammography unit with a Kodak MinR 2190-MinR L screen-film combination and a Senograph 2000D (General Electric) digital mammography unit. Objective image quality assessments for different breast tissue compositions were performed using the phantom for conventional and digital mammography. For a similar mean glandular dose (MGD), the digital system gives a significantly higher contrast-to-noise ratio (CNR) than the screen-film system for 100% glandular tissue. In conclusion, in mammography, a range of exposure conditions is used for imaging because of the different breast tissue compositions encountered clinically. Ideally, the patient dose-image quality relationship should be optimized over the range of exposure conditions. The test phantom presented in this work permits image quality parameters to be evaluated objectively for three different types of breast tissue. Thus, it is a useful tool for optimizing the patient dose-image quality relationship

  12. Communication, Cultural Models of Breast Cancer Beliefs and Screening Mammography: An Assessment of Attitudes Among Haitian Immigrant Women in Eastern Massachusetts

    National Research Council Canada - National Science Library

    David, Michele

    2000-01-01

    ... forthcoming about this adherence. Many Haitian immigrant women are not aware of the purpose of screening mammography, and present late for evaluation of breast lumps and abnormal findings at mammography...

  13. Communication, Cultural Models of Breast Cancer Beliefs and Screening Mammography: An Assessment of Attitudes Among Haitian Immigrant Women in Eastern MA

    National Research Council Canada - National Science Library

    David, Michele

    2001-01-01

    ... forthcoming about this adherence. Many Haitian immigrant women are not aware of the purpose of screening mammography, and present late for evaluation of breast lumps and abnormal findings at mammography...

  14. Image quality control of mammography equipment -Mammography System MX-300- of the Teachers Hospital of UNSA and dose measurement in breasts with radiographic films

    International Nuclear Information System (INIS)

    Quispe F, L. K.; Vega R, J.

    2015-10-01

    This work is part of medical imaging for the evaluation of quality. Will have an accredited breast phantom Rmi-156 that allows evaluating the image quality of mammography equipment and through a series of techniques and processes that will submit to mammography films we obtain characteristic curves, which allows to evaluate different parameters that will serve for our study. Images were acquired with different k Vp and m As of the equipment, also with different thicknesses of the breast phantom. Also we want to use the lowest possible dose for obtaining our images. In this paper we develop a simple protocol that aims to unify the conditions under which are acquired the images for later evaluation. By obtaining these characteristic curves demonstrate that the Kodak film is the most suitable for our study because it requires lower dose for obtaining our images. (Author)

  15. Overdiagnosis in publicly organised mammography screening programmes: systematic review of incidence trends

    DEFF Research Database (Denmark)

    Jørgensen, Karsten Juhl; Gøtzsche, Peter C

    2009-01-01

    . DATA SOURCES: PubMed (April 2007), reference lists, and authors. Review methods One author extracted data on incidence of breast cancer (including carcinoma in situ), population size, screening uptake, time periods, and age groups, which were checked independently by the other author. Linear regression......OBJECTIVE: To estimate the extent of overdiagnosis (the detection of cancers that will not cause death or symptoms) in publicly organised screening programmes. DESIGN: Systematic review of published trends in incidence of breast cancer before and after the introduction of mammography screening...... was used to estimate trends in incidence before and after the introduction of screening and in older, previously screened women. Meta-analysis was used to estimate the extent of overdiagnosis. RESULTS: Incidence data covering at least seven years before screening and seven years after screening had been...

  16. Barriers to Organized Mammography Screening Programs in Hungary: A Questionnaire-based Study of 3,313 Women.

    Science.gov (United States)

    Újhelyi, Mihály; Pukancsik, Dávid; Kelemen, Péter; Kovács, Eszter; Kenessey, István; Bak, Mihály; Kásler, Miklós; Kovács, Tibor; Mátrai, Zoltán

    2018-03-01

    Despite well-organized Hungarian invitational mammography screening, participation rates have never reached 50%. This is similar to rates in Central Eastern Europe. In order to reduce breast cancer mortality, the participation rate should be at least 70%. This questionnaire-based study assessed the barriers associated with low adherence rates. Women 45-65 years of age were interviewed by questionnaire containing 15 structured questions focused on socioeconomic status and barriers to screening. A total of 3,313 women completed the questionnaire. The main reasons for avoiding screening were work absenteeism (18.9%), fear of painful examination (18.39%), and poor understanding of mammography screening (14.94%). Education is required to increase awareness among women about the utility and availability of breast screening services. This report provides information on the appropriate level of intervention needed to increase screening participation in Hungary and other developing countries in Central Eastern Europe to reduce breast cancer-related mortality. Copyright© 2018, International Institute of Anticancer Research (Dr. George J. Delinasios), All rights reserved.

  17. Study of signal-to-noise ratio in digital mammography

    Science.gov (United States)

    Kato, Yuri; Fujita, Naotoshi; Kodera, Yoshie

    2009-02-01

    Mammography techniques have recently advanced from those using analog systems (the screen-film system) to those using digital systems; for example, computed radiography (CR) and flat-panel detectors (FPDs) are nowadays used in mammography. Further, phase contrast mammography (PCM)-a digital technique by which images with a magnification of 1.75× can be obtained-is now available in the market. We studied the effect of the air gap in PCM and evaluated the effectiveness of an antiscatter x-ray grid in conventional mammography (CM) by measuring the scatter fraction ratio (SFR) and relative signal-to-noise ratio (rSNR) and comparing them between PCM and the digital CM. The results indicated that the SFRs for the CM images obtained with a grid were the lowest and that these ratios were almost the same as those for the PCM images. In contrast, the rSNRs for the PCM images were the highest, which means that the scattering of x-rays was sufficiently reduced by the air gap without the loss of primary x-rays.

  18. The 20-year effort to reduce access to mammography screening: historical facts dispute a commentary in Cancer.

    Science.gov (United States)

    Kopans, Daniel B; Webb, Matthew L; Cady, Blake

    2014-09-15

    Mammography screening fulfills all requirements for an effective screening test. It detects many cancers earlier when they are at a smaller size and earlier stage, and it has been demonstrated that this reduces breast cancer deaths in randomized controlled trials. When screening is introduced into the population, the death rate from breast cancer declines. Nevertheless, scientifically unsupported arguments that appear in the medical literature are passed on to the public and continue to confuse women and physicians regarding the value of screening. Methodologically flawed challenges to mammography have been almost continuous since the 1990s. And, as each challenge has been invalidated, a new, specious challenge has been raised. The authors of this report address the long history of misinformation that has developed in the effort to reduce access to screening, and they address the issues raised by commentators concerning their recent publication in this journal. © 2014 American Cancer Society.

  19. Psychosocial predictors of first attendance for organised mammography screening

    DEFF Research Database (Denmark)

    Aro, A R; de Koning, H J; Absetz, P

    1999-01-01

    Scale, Illness Attitude Scale, Health Locus of Control Scale, Anxiety Inventory, and Depression Inventory. Univariate and multivariate logistic regression analyses were used to predict attendance. RESULTS: Those most likely to attend were working, middle income, and averagely educated women, who had...... not had a mass mammogram recently, but who regularly visited gynaecologists, attended for Pap smear screening, practised breast self examination, and who did not smoke. Low confidence in their own capabilities in breast cancer prevention, overoptimism about the sensitivity of mammography, and perception...

  20. Performance of screening mammography: A report of the alliance for breast cancer screening in Korea

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Eun Hye [Bucheon Hospital, Soonchunhyang University College of Medicine, Bucheon (Korea, Republic of); Kim, Keum Woo [Konyang University Hospital, Konyang University College of Medicine, Daejeon (Korea, Republic of); Kim, Young Joong [Gangneung Asan Hospital, University of Ulsan College of Medicine, Gangneung (Korea, Republic of); and others

    2016-07-15

    To analyze the diagnostic accuracy and trend in screening mammography in Korea. We retrospectively linked the information from hospitals participating in the Alliance of Breast Cancer Screening in Korea (ABCS-K) and the database of the National Cancer Screening Program. We calculated performance indicators, including the recall rate, cancer detection rate (CDR), positive predictive value (PPV), sensitivity, specificity, false-positive rate (FPR), and interval cancer rate (ICR). Changes in the performance indicators were calculated as the annual percent change with 95% confidence interval (CI). We enrolled 128756 cases from 10 hospitals from 2005 to 2010. The recall rate was 19.1% with a downward trend over time (-12.1% per year; 95% CI, -15.9 to -8.2). The CDR was 2.69 per 1000 examinations, without a significant trend. The PPV was 1.4% with an upward trend (20.8% per year; 95% CI, 15.2 to 26.7). The sensitivity was 86.5% without a significant trend, whereas the specificity was 81.1% with an upward trend (3.3% per year; 95% CI, 2.1 to 4.5). The FPR was 18.9% with a downward trend (-12.4% per year; 95% CI, -16.2 to -8.4). The ICR was 0.5 per 1000 negative examinations without a significant trend. There were institutional variations in the diagnostic accuracy and trend except for the CDR, sensitivity, and ICR. The sensitivity and CDR of screening mammography in the ABCS-K from 2005 to 2010 were compatible with those for Western women. The recall rate, PPV and specificity, however, were suboptimal, although they showed significant improvements over this period. A further analysis is required to explain institutional variations.

  1. Mammography Screening Trends: The Perspective of African American Women Born Pre/Post World War II

    Science.gov (United States)

    Williams, Karen Patricia; Mabiso, Athur; Lo, Yun-Jia; Penner, Louis A.

    2013-01-01

    Researchers have traditionally combined aging women (aged ≥50 years) when reporting their mammography use. This may inadvertently mask important cohort effects in mammography use, which are likely to result from distinct personal life experiences and generational differences. Using the Health and Retirement Study samples of 1998, 2000, and 2004, we examined cohort differences in mammography use between African American women born before 1946 (non–baby boomers) and those born in 1946 to 1953 (baby boomers). Between 1998 and 2004, screening rates for non–baby boomers declined, while those for baby boomers remained relatively steady. Hierarchical linear modeling (HLM) analyses suggest that while screening rates decreased with age (OR, 0.957; 95% CI, 0.947–0.968) cohort effects may have partially reversed the age effect, with non–baby boomers having an increased likelihood of receiving a mammogram compared to baby boomers (OR, 1.697; 95% CI, 1.278–2.254). Because African American women are diagnosed at later stages of breast cancer, documentation of cohort differences in mammography use among older African American women is important as health care professionals design intervention programs that are maximally effective for women from different cohorts. This is particularly critical as more African American women in the baby boomer cohort become part of the aging population. PMID:20575209

  2. Level and distribution of the radiation dose to the population from a mammography screening programme in New Zealand

    Energy Technology Data Exchange (ETDEWEB)

    Bulling, S.M.; Nicoll, J.J. [Otago Univ., Dunedin (New Zealand). Dept. of Physics

    1995-12-31

    The Otago Southland Breast Screening Programme offers biennial mammography to 19,000 eligible women on the South Island of New Zealand. A Quality Assurance programme ensures that international performance standards are met, in particular the radiation dose for a mammogram of 5 cm CIRS-X phantom is 1.7 mGy and careful retake analysis undertaken. This however does not reveal the absorbed dose received by individuals, nor how this varies between individuals. Machine parameters and compressed breast thickness for each film were recorded for 310 women who attended one centre during the three months ending February 1993 and absorbed doses calculated using Monte Carlo data. The mean compressed breast thickness for the 310 women was 4.9 cm, doses received for individual films ranged from 0.7 to 8.5 mGy while patient total doses were in the range 4 to 29 mGy with 75% of women receiving a dose of 7.1 mGy or less. (Author).

  3. A Case-Control Study to Estimate the Impact of the Icelandic Population-Based Mammography Screening Program on Breast Cancer Death

    Energy Technology Data Exchange (ETDEWEB)

    Gabe, R.; Tryggvadottir, L.; Sigfusson, B.F.; Olafsdottir, G.H.; Sigurarsson , K. [Icelandic Cancer Society (Krabbameinsfelag Islands), Reykjavik (Iceland); Duffy, S.W. [Cancer Research UK, Centre for Epidemiology, Mathematics and Stati stics, Wolfson Inst. of Preventive Medicine, London (United Kingdom)

    2007-11-15

    Background: The Icelandic breast cancer screening program, initiated November 1987 in Reykjavik and covering the whole country from December 1989, comprises biennial invitation to mammography for women aged 40-69 years old. Purpose: To estimate the impact of mammography service screening in Iceland on deaths from breast cancer. Material and Methods: Cases were deaths from breast cancer from 1990 onwards in women aged 40 and over at diagnosis, during the period November 1987 to December 31, 2002. Age- and screening-area-matched, population-based controls were women who had also been invited to screening but were alive at the time their case died. Results: Using conditional logistic regression on the data from 226 cases and 902 controls, the odds ratio for the risk of death from breast cancer in those attending at least one screen compared to those never screened was 0.59 (95% CI 0.41-0.84). After adjustment for healthy-volunteer bias and screening-opportunity bias, the odds ratio was 0.65 (95% CI 0.39-1.09). Conclusion: These results indicate a 35-40% reduction in breast cancer deaths by attending the Icelandic breast cancer screening program. These results are consistent with the overall evidence from other observational evaluations of mammography-based programs.

  4. A Case-Control Study to Estimate the Impact of the Icelandic Population-Based Mammography Screening Program on Breast Cancer Death

    International Nuclear Information System (INIS)

    Gabe, R.; Tryggvadottir, L.; Sigfusson, B.F.; Olafsdottir, G.H.; Sigurarsson, K.; Duffy, S.W.

    2007-01-01

    Background: The Icelandic breast cancer screening program, initiated November 1987 in Reykjavik and covering the whole country from December 1989, comprises biennial invitation to mammography for women aged 40-69 years old. Purpose: To estimate the impact of mammography service screening in Iceland on deaths from breast cancer. Material and Methods: Cases were deaths from breast cancer from 1990 onwards in women aged 40 and over at diagnosis, during the period November 1987 to December 31, 2002. Age- and screening-area-matched, population-based controls were women who had also been invited to screening but were alive at the time their case died. Results: Using conditional logistic regression on the data from 226 cases and 902 controls, the odds ratio for the risk of death from breast cancer in those attending at least one screen compared to those never screened was 0.59 (95% CI 0.41-0.84). After adjustment for healthy-volunteer bias and screening-opportunity bias, the odds ratio was 0.65 (95% CI 0.39-1.09). Conclusion: These results indicate a 35-40% reduction in breast cancer deaths by attending the Icelandic breast cancer screening program. These results are consistent with the overall evidence from other observational evaluations of mammography-based programs

  5. Mass screening in breast cancer

    International Nuclear Information System (INIS)

    Strax, P.

    1977-01-01

    Some questions about mass screening in breast cancer are answered it being concluded that: 1. mass screening for the detection of early breast cancer is the only means with proven potential for lowering the death rate of the disease; 2. mammography is an importante - if not the most important modality in mass screening; 3. new film - screen combinations generally available are capable of producing mammograms of excelent quality with radiation doses down to .1 rad into the body of breast. The risk of malignant changes from such dosage - even when given periodically is negligeable. New equipment, to be available, shortly, will use the new film - screen combinations in an automated manner with must reduce cost in time, filme, personnel and processing - of more than 50%. This would make mass screening more practical. (M.A.) [pt

  6. Screening Mammography: Science, Policy and Politics–The Good, the Bad and the Ugly

    Science.gov (United States)

    Diana Petitti, MD, MPH, FACPM, an epidemiologic expert on women's health and evidence based medicine, with posts as vice chair and spokesperson for the U.S. Preventive Service Task Force, presented "Screening Mammography: Science, Policy and Politics–The Good, the Bad and the Ugly." 

  7. Mammography for women in their 40s : to screen or not to screen

    International Nuclear Information System (INIS)

    Le Heron, J.

    1997-01-01

    In the United States there is currently a raging controversy as to whether women in their 40s should be screened for breast cancer, with responsible medical bodies each issuing divergent recommendations. With the imminent commencement of the national breast screening programme in New Zealand, it is relevant to briefly review what underlies these differences. The evicence from international studies is that breast cancer deaths on the population of women aged 50 to 69 can be reduced by about 30% by good mammography screening programes. However the evidence in not so unequivocal for the 40 to 49 age group. Breast cancer in younger women tends to be more virulent, growing faster, and killing faster, and detection of cancer in younger breasts is more difficult than in breasts of older women due to the presence of greater amounts of glandular tissue. Where does this leave breast screening in New Zealand? The nationwide breast screening programme will commence with asymmptomatic women aged 50-64 eligible for screening. Extension to women older than 64 will be considered again once the programme is in place and running well. The Ministry of Health has not recommended routine screening for women in their 40s, but will continue to monitor the latest information and if, sufficient new evidence becomes availabe, the screening guidelines will be reassessed. (author)

  8. False-positive findings in mammography screening induces short-term distress - breast cancer-specific concern prevails longer

    DEFF Research Database (Denmark)

    Aro, A R; Pilvikki Absetz, S; van Elderen, T M

    2000-01-01

    The aim of this study was to examine psychological distress in a mammography screening process as a consequence of screening after adjusting for background, personality and prescreening distress. Subjects, aged 50 years, were invitees at their first screening. There were three groups; normal find...... perceived breast cancer risk and susceptibility. Distress related to screening and false-positive findings seems to be moderate, but prevailing cancer-specific concerns call for improvements in screening programmes....

  9. Barriers related to non-adherence in a mammography breast-screening program during the implementation period in the interior of São Paulo State, Brazil

    Directory of Open Access Journals (Sweden)

    René Aloisio da Costa Vieira

    2015-09-01

    Full Text Available Mammography is the best exam for early diagnosis of breast cancer. Developing countries frequently have a low income of mammography and absence of organized screening. The knowledge of vulnerable population and strategies to increase adherence are important to improve the implementation of an organized breast-screening program. A mammography regional-screening program was implemented in a place around 54.238 women, aged 40–69 years old. It was proposed to perform biannual mammography free of cost for the women. We analyze the first 2 years of the implementation of the project. Mammography was realized in 17.964 women. 42.1% of the women hadn’t done de mammography in their lives and these women were principally from low socio-economic status (OR = 2.99, low education (OR = 3.00. The best strategies to include these women were mobile unit (OR = 1.43 and Family Health Program (OR = 1.79. The incidence of early breast tumors before the project was 14.5%, a fact that changed to 43.2% in this phase. Multivariate analysis showed that the association of illiterate and the mobile unit achieve more women who had not performed mammography in their lives. The strategies to increase adherence to mammography must be multiple and a large organization is necessary to overpass the barriers related to system health and education.

  10. The Role of Effective Communication to Enhance Participation in Screening Mammography: A New Zealand Case

    Directory of Open Access Journals (Sweden)

    Margaret A. Brunton

    2009-02-01

    Full Text Available Changes in the organisation of health care have dominated policy initiatives over the past two decades in many countries. An increasing reliance on public health initiatives to prevent or detect disease early has resulted in an increase in programs that screen for cancer in the community. In turn, this accentuates the need to persuasively communicate the value of such initiatives to encourage continued participation. Merely placing screening programs into a community setting is not sufficient to ensure that adequate numbers will voluntarily participate regularly to achieve anticipated cost and mortality savings in the population. In this research the influence of managing communication in a public screening mammography program was investigated. The results revealed that significant opportunities were overlooked for reassurance and information during the physical mammography process. In turn, this highlights the influence of constraints imposed by the structure of the screening program and the resources allocated to the process. This research suggests that it is important to address multiple influences, including ethnic differences, when asking questions about the effectiveness of public health policy, particularly when considering the choices women make about ongoing participation in breast screening programs.

  11. Travel Times for Screening Mammography: Impact of Geographic Expansion by a Large Academic Health System.

    Science.gov (United States)

    Rosenkrantz, Andrew B; Liang, Yu; Duszak, Richard; Recht, Michael P

    2017-09-01

    This study aims to assess the impact of off-campus facility expansion by a large academic health system on patient travel times for screening mammography. Screening mammograms performed from 2013 to 2015 and associated patient demographics were identified using the NYU Langone Medical Center Enterprise Data Warehouse. During this time, the system's number of mammography facilities increased from 6 to 19, reflecting expansion beyond Manhattan throughout the New York metropolitan region. Geocoding software was used to estimate driving times from patients' homes to imaging facilities. For 147,566 screening mammograms, the mean estimated patient travel time was 19.9 ± 15.2 minutes. With facility expansion, travel times declined significantly (P travel times between such subgroups. However, travel times to pre-expansion facilities remained stable (initial: 26.8 ± 18.9 minutes, final: 26.7 ± 18.6 minutes). Among women undergoing mammography before and after expansion, travel times were shorter for the postexpansion mammogram in only 6.3%, but this rate varied significantly (all P travel burden and reduce travel time variation among sociodemographic populations. Nonetheless, existing patients strongly tend to return to established facilities despite potentially shorter travel time locations, suggesting strong site loyalty. Variation in travel times likely relates to various factors other than facility proximity. Copyright © 2017 The Association of University Radiologists. Published by Elsevier Inc. All rights reserved.

  12. [Quality assurance of fine-needle aspiration cytology of the organized mammography screening].

    Science.gov (United States)

    Bak, Mihály; Konyár, Eva; Schneider, Ferenc; Bidlek, Mária; Szabó, Eva; Nyári, Tibor; Godény, Mária; Kásler, Miklós

    2010-08-08

    The National Public Health Program has established the organized mammography screening in Hungary. The aim of our study was to determine the quality assurance of breast aspiration cytology. Cytology results were rated to 5 categories (C1, C2, C3, C4 and C5). All cytology reports were compared with the final histology diagnosis. 1361 women had aspiration cytology diagnosis performed from a total of 47718 mammography non-negative lesions. There were 805 (59.1%) benign and 187 (13.7%) malignant alterations. Sensitivity was 91%, specificity 88%, positive predictive value 96.6% and negative predictive value turned to be 71% (pauditing values of fine needle aspiration cytology in our laboratory meet, or in certain aspects exceed the proposed minimum threshold values.

  13. On the possibility of reducing doses received by patients during mammography screening

    International Nuclear Information System (INIS)

    Tolwinski, J.; Fabiszewska, E.; Gwiazdowska, B.; Bulski, W.

    2005-01-01

    possibility of decreasing the individual doses by proper selection of the high voltage value. The parameters, resulting from the histograms of the Di values (mode, median, mean),shown in Figures 2, 3 and 4 are summarized and compared with the standard AGD calculated for the same unit (Table I). The results show that the acceptance of a single parameter for evaluation of doses received by patients during mammography examinations is insufficient. The assessment of the standard AGD is insufficient for the evaluation of the procedures of mammography screening. The histograms of individual dose distribution should be used for controlling of the conditions of these examinations. (author)

  14. Screening and prevention of breast cancer in primary care.

    Science.gov (United States)

    Tice, Jeffrey A; Kerlikowske, Karla

    2009-09-01

    Mammography remains the mainstay of breast cancer screening. There is little controversy that mammography reduces the risk of dying from breast cancer by about 23% among women between the ages of 50 and 69 years, although the harms associated with false-positive results and overdiagnosis limit the net benefit of mammography. Women in their 70s may have a small benefit from screening mammography, but overdiagnosis increases in this age group as do competing causes of death. While new data support a 16% reduction in breast cancer mortality for 40- to 49-year-old women after 10 years of screening, the net benefit is less compelling in part because of the lower incidence of breast cancer in this age group and because mammography is less sensitive and specific in women younger than 50 years. Digital mammography is more sensitive than film mammography in young women with similar specificity, but no improvements in breast cancer outcomes have been demonstrated. Magnetic resonance imaging may benefit the highest risk women. Randomized trials suggest that self-breast examination does more harm than good. Primary prevention with currently approved medications will have a negligible effect on breast cancer incidence. Public health efforts aimed at increasing mammography screening rates, promoting regular exercise in all women, maintaining a healthy weight, limiting alcohol intake, and limiting postmenopausal hormone therapy may help to continue the recent trend of lower breast cancer incidence and mortality among American women.

  15. The comparative evaluation of film-screen combinations

    International Nuclear Information System (INIS)

    Choi, Gyung Ja; Choi, Syng Kyu

    1988-01-01

    This study was to compare the quality of image by different screen and film combinations. Using the sensitometer measured the speed and average gradient of blue sensitive films and orthochromatic films. The films was combined with rare earth screen LR, Lm, LF and conventional screen OM, OH, XOR, OKa and exposed the stepwedge to impulse 2, 3, 4, 6, 10, 15, 24, 38, 60 and measured the density. The following results were obtained: 1. The density of film and film-screen combinations showed significant difference, then in film-screen combinations was significantly different by the screens than films. 2. The speed of blue sensitive films was little different, the TMG of orthochromatic films producted high speed, and the AX films was high average gradient. 3. The relative speed of film-screen combinations showed significant difference, and was high in the OKa of the conventional screens and in the LR of the rare earth screens, especially that of LR screen in the combination with blue sensitive films was high. 4. The average gradient of film-screen combinations showed no significant difference, and was high in the OKa screen and LR/OG combination, and that of OKa/AX combination was highest. 5. The latitude of film-screen combinations showed significant difference by screens, and was high in the LM screen in combination with blue sensitive films and in the OM screen in combination with orthochromatic films. 6. The subject contrast of film-screen combinations showed significant difference by screen, and was high in the LR screen in combination with blue sensitive AX film and orthochromatic TMG film.

  16. Adherence to Mammography Screening Guidelines Among Transgender Persons and Sexual Minority Women.

    Science.gov (United States)

    Bazzi, Angela Robertson; Whorms, Debra S; King, Dana S; Potter, Jennifer

    2015-11-01

    We used retrospective (2012-2013) chart review to examine breast cancer screening among transgender persons and sexual minority women (n = 1263) attending an urban community health center in Massachusetts. Transgender were less likely than cisgender patients and bisexuals were less likely than heterosexuals and lesbians to adhere to mammography screening guidelines (respectively, adjusted odds ratios = 0.53 and 0.56; 95% confidence intervals = 0.31, 0.91 and 0.34, 0.92) after adjustment for sociodemographics. Enhanced cancer prevention outreach is needed among gender and sexual minorities.

  17. Exploratory survey of image quality on CR digital mammography imaging systems in Mexico

    International Nuclear Information System (INIS)

    Gaona, E.; Rivera, T.; Arreola, M.; Franco, J.; Molina, N.; Alvarez, B.; Azorín, C.G.; Casian, G.

    2014-01-01

    The purpose of this study was to assess the current status of image quality and dose in computed radiographic digital mammography (CRDM) systems. Studies included CRDM systems of various models and manufacturers which dose and image quality comparisons were performed. Due to the recent rise in the use of digital radiographic systems in Mexico, CRDM systems are rapidly replacing conventional film-screen systems without any regard to quality control or image quality standards. Study was conducted in 65 mammography facilities which use CRDM systems in the Mexico City and surrounding States. The systems were tested as used clinically. This means that the dose and beam qualities were selected using the automatic beam selection and photo-timed features. All systems surveyed generate laser film hardcopies for the radiologist to read on a scope or mammographic high luminance light box. It was found that 51 of CRDM systems presented a variety of image artefacts and non-uniformities arising from inadequate acquisition and processing, as well as from the laser printer itself. Undisciplined alteration of image processing settings by the technologist was found to be a serious prevalent problem in 42 facilities. Only four of them showed an image QC program which is periodically monitored by a medical physicist. The Average Glandular Dose (AGD) in the surveyed systems was estimated to have a mean value of 2.4 mGy. To improve image quality in mammography and make more efficient screening mammographic in early detection of breast cancer is required new legislation. - Highlights: • Radiation dose in CR digital mammography (CRDM) systems was determined. • Image quality related with dose in CR digital mammography (CRDM) systems was analysed. • Image processing artefacts were observed and correlated with dose. • Measured entrance dose by TL phosphors could be good parameter for radiation protection optimization in patient

  18. Relative and combined performance of mammography and ultrasonography for breast cancer screening in the general population. A pilot study in Tochigi prefecture, Japan

    International Nuclear Information System (INIS)

    Honjo, Satoshi; Ando, Jiro; Tsukioka, Takeo

    2007-01-01

    Breast cancer screening by mammography is thought to be effective in reducing breast cancer mortality while ultrasonography is not accepted as a population screening modality, although the latter has been suggested to be useful in detection of cancer in the dense breast, relatively more typical for a younger woman. Mammography with medio-lateral oblique view was offered on trial in 1999-2000 for 3453 female residents in Tochigi prefecture who also underwent clinical breast examination and ultrasonography. The municipalities that provided cancer screening were informed of the final diagnosis for women with positive findings in the screening trial by doctors who performed the diagnostic evaluation. Linkage was also made between the list of participants in the trial and registrations at Tochigi Cancer Registry for breast cancer cases diagnosed during 1999-2001. Thirteen cases with breast cancer were identified during a 2-year follow-up period: 10 were diagnosed subsequent to positive finding in the trial; two were negative in the trial and diagnosed 23 and 24 months after, respectively; and one had a positive finding at the trial but was undiagnosed at first and then diagnosed 18 months after the trial. Among the 11 cases judged as positive in the trial, four were judged only by mammography while three were judged only by ultrasonography. Those mammography alone-detected cases were relatively young, at 36, 40, 47 and 54 years of age, respectively, while the ultrasonography alone-detected cases were aged 50, 55 and 68, respectively. Combined screening with mammography and ultrasonography may be feasible. A larger study is required to evaluate relative performance of mammography and ultrasonography in detail by characteristics of examinees and their breasts. (author)

  19. Predictors of Participation in Mammography Screening among non-Hispanic Black, non-Hispanic White, and Hispanic Women

    Directory of Open Access Journals (Sweden)

    Cathy Melvin

    2016-09-01

    Full Text Available Introduction: Many factors influence women’s decisions to participate in guideline recommended screening mammography. We evaluated the influence of women’s socioeconomic characteristics, healthcare access, and cultural and psychological healthcare preferences on timely mammography screening participation.Materials and methods: A random digit dial survey of United States non-Hispanic Black, non-Hispanic White, and Hispanic women ages 40-75, from January-August 2009 determined self- reported time of most recent mammogram. Screening rates were assessed based on receipt of a screening mammogram within the prior 12 months, the interval recommended at the time by the American Cancer Society.Results: Thirty-nine percent of women reported not having a mammogram within the last 12 months. The odds of not having had a screening mammography was higher for non-Hispanic White women than for non-Hispanic Black (OR=2.16, 95% CI=0.26, 0.82, p=0.009 or Hispanic (OR=4.17, 95% CI=0.12, 0.48, p=0.01 women. Lack of health insurance (OR=3.22, 95% CI=1.54, 6.73, p=0.002 and lack of usual source of medical care (OR=3.37, 95% CI=1.43, 7.94, p=0.01 were associated with not being screened as were lower self-efficacy to obtain screening (OR=2.43, 95% CI=1.26, 4.73, p=0.01 and greater levels of religiosity and spirituality (OR=1.42, 95% CI=1.00, 2.00, p=0.05. Neither perceived risk nor present temporal orientation was significant.Discussion: Odds of not having a mammogram increased if women were uninsured, without medical care, non-Hispanic white, older in age, not confident in their ability to obtain screening, or held passive or external religious/spiritual values. Results are encouraging given racial disparities in healthcare participation and suggest that efforts to increase screening among minority women may be working.

  20. Magnetic Resonance Imaging as an Adjunct to Mammography for Breast Cancer Screening in Women at Less Than High Risk for Breast Cancer: A Health Technology Assessment

    Science.gov (United States)

    Nikitovic-Jokic, Milica; Holubowich, Corinne

    2016-01-01

    Background Screening with mammography can detect breast cancer early, before clinical symptoms appear. Some cancers, however, are not captured with mammography screening alone. Among women at high risk for breast cancer, magnetic resonance imaging (MRI) has been suggested as a safe adjunct (supplemental) screening tool that can detect breast cancers missed on screening mammography, potentially reducing the number of deaths associated with the disease. However, the use of adjunct screening tests may also increase the number of false-positive test results, which may lead to unnecessary follow-up testing, as well as patient stress and anxiety. We investigated the benefits and harms of MRI as an adjunct to mammography compared with mammography alone for screening women at less than high risk (average or higher than average risk) for breast cancer. Methods We searched Ovid MEDLINE, Ovid Embase, Cochrane Central Register of Controlled Trials, Cochrane Database of Systematic Reviews, Database of Abstracts of Reviews of Effects (DARE), Centre for Reviews and Dissemination (CRD) Health Technology Assessment Database, and National Health Service (NHS) Economic Evaluation Database, from January 2002 to January 2016, for evidence of effectiveness, harms, and diagnostic accuracy. Only studies evaluating the use of screening breast MRI as an adjunct to mammography in the specified populations were included. Results No studies in women at less than high risk for breast cancer met our inclusion criteria. Conclusions It remains uncertain if the use of adjunct screening breast MRI in women at less than high risk (average or higher than average risk) for breast cancer will reduce breast cancer–related mortality without significant increases in unnecessary follow-up testing and treatment. PMID:27990198

  1. American Indian Women and Screening Mammography: Findings from a Qualitative Study in Oklahoma

    Science.gov (United States)

    Tolma, Eleni; Batterton, Chasity; Hamm, Robert M.; Thompson, David; Engelman, Kimberly K.

    2012-01-01

    Background: Breast cancer is an important public health issue within the American Indian (AI) community in Oklahoma; however, there is limited information to explain the low screening mammography rates among AI women. Purpose: To identify the motivational factors affecting an AI woman's decision to obtain a mammogram. Methods: Through the use of…

  2. Screening mammography: a successful public health initiative El tamizaje mamográfico: una iniciativa de salud pública que ha dado buenos resultados

    Directory of Open Access Journals (Sweden)

    Stephen A. Feig

    2006-09-01

    Full Text Available This paper reviews the ability of screening mammography to reduce breast cancer death rates, and it discusses methods that maximize benefits and reduce false-positive interpretations in a screening program. The review covers published results from screening mammography programs conducted in Europe and North America, along with quality assurance measures designed to ensure that similar or even better outcomes will be shared by other populations of screened women. Randomized trials in Europe and the United States of America have shown the benefit from screening women ages 40-70 years. Encouraged by the success of these trials, many Scandinavian countries now offer screening mammography to their populations as a public health service. These service screening programs have reduced breast cancer deaths as much as 63% among women who were screened. In the United States, where 61.5% of women age 40 and older report having had a mammogram in the preceding year, death rates from breast cancer have been falling despite an increasing incidence of the disease. The technical quality of mammography in the United States has improved as a result of advances in mammography equipment, including the film-screen systems. Also contributing to the improvement has been the implementation of federally mandated quality control testing at each mammography facility, as required by the Mammography Quality Standards Act (MQSA, which the Congress of the United States approved in 1992. Factors that result in increased detection of early-stage cancers include better technique, use of two mammographic views per breast, annual screening intervals, and improved interpretation. Mammography is one of the 10 major subject categories on the American Board of Radiology examinations. Furthermore, MQSA requires radiologists who practice mammography to obtain continuing medical education credits and to use standard interpretation assessments on every report. Manuals for technical quality

  3. [Fine needle aspiration cytology of mammography screening

    DEFF Research Database (Denmark)

    Engvad, B.; Laenkholm, A.V.; Schwartz, Thue W.

    2009-01-01

    INTRODUCTION: In the year 2000 a quality assurance programme for the preoperative breast diagnostics was introduced in Denmark. The programme was based on the "European guidelines for quality assurance in breast cancer screening and diagnosis" where - among other measures - five cytological......-choice treatment. MATERIAL AND METHODS: 767 women had FNAC performed from a total of 783 lesions at the Mammography Clinic, University Hospital Odense. All FNACs were compared with the final histology diagnosis. Nine statistical parameters were calculated according to the European guidelines. RESULTS: A total...... of 66% of the 783 FNACs had a malignant cytology diagnosis, which in 99% of the cases turned out to be the correct diagnosis. Four lesions were false positives all of which represented benign proliferative breast diseases. The surgical procedures in these cases were either excisional biopsy...

  4. Radiographers supporting radiologists in the interpretation of screening mammography: a viable strategy to meet the shortage in the number of radiologists

    International Nuclear Information System (INIS)

    Torres-Mejía, Gabriela; Smith, Robert A.; Carranza-Flores, María de la Luz; Bogart, Andy; Martínez-Matsushita, Louis; Miglioretti, Diana L.; Kerlikowske, Karla; Ortega-Olvera, Carolina; Montemayor-Varela, Ernesto; Angeles-Llerenas, Angélica; Bautista-Arredondo, Sergio; Sánchez-González, Gilberto; Martínez-Montañez, Olga G.; Uscanga-Sánchez, Santos R.; Lazcano-Ponce, Eduardo; Hernández-Ávila, Mauricio

    2015-01-01

    An alternative approach to the traditional model of radiologists interpreting screening mammography is necessary due to the shortage of radiologists to interpret screening mammograms in many countries. We evaluated the performance of 15 Mexican radiographers, also known as radiologic technologists, in the interpretation of screening mammography after a 6 months training period in a screening setting. Fifteen radiographers received 6 months standardized training with radiologists in the interpretation of screening mammography using the Breast Imaging Reporting and Data System (BI-RADS) system. A challenging test set of 110 cases developed by the Breast Cancer Surveillance Consortium was used to evaluate their performance. We estimated sensitivity, specificity, false positive rates, likelihood ratio of a positive test (LR+) and the area under the subject-specific Receiver Operating Characteristic (ROC) curve (AUC) for diagnostic accuracy. A mathematical model simulating the consequences in costs and performance of two hypothetical scenarios compared to the status quo in which a radiologist reads all screening mammograms was also performed. Radiographer’s sensitivity was comparable to the sensitivity scores achieved by U.S. radiologists who took the test but their false-positive rate was higher. Median sensitivity was 73.3 % (Interquartile range, IQR: 46.7–86.7 %) and the median false positive rate was 49.5 % (IQR: 34.7–57.9 %). The median LR+ was 1.4 (IQR: 1.3-1.7 %) and the median AUC was 0.6 (IQR: 0.6–0.7). A scenario in which a radiographer reads all mammograms first, and a radiologist reads only those that were difficult for the radiographer, was more cost-effective than a scenario in which either the radiographer or radiologist reads all mammograms. Given the comparable sensitivity achieved by Mexican radiographers and U.S. radiologists on a test set, screening mammography interpretation by radiographers appears to be a possible adjunct to radiologists

  5. Understanding recall rates in screening mammography: A conceptual framework review of the literature

    International Nuclear Information System (INIS)

    Mohd Norsuddin, N.; Reed, W.; Mello-Thoms, C.; Lewis, S.J.

    2015-01-01

    Recall rates are one of the performance measures used to evaluate the effectiveness of mammography screening programs. There is conflicting evidence regarding the link between recall rates and cancer detection rates and a variety of differing recall rates exist between countries and readers. This variability in recall rates may have important clinical and economic implications such as unnecessary follow-up procedures, additional costs to the health care system and psychological effects for the women themselves associated with false-positive mammograms results. In order to reduce the impact of false positive recall rates in screening mammography, it is essential for all multidisciplinary health care providers, especially those in medical imaging, to fully understand the factors that may contribute and affect recall rates. The multifactorial nature of recall rates is explored in this paper through the construction of a conceptual map based on a review of the current literature. - Highlights: • Recall rates vary across countries and readers and for initial and subsequent screens. • Falsely recalling women has important clinical, cost and psycho-social implications. • Imaging technology, readers' expertise and patient presentation affect recall rates. • Higher recall rates do not translate into improved sensitivity at higher thresholds. • Multidisciplinary approaches to reduce recall rates may improve women experiences.

  6. Bavarian mammography screening program; Bayerisches Mammographiescreening (BMS)

    Energy Technology Data Exchange (ETDEWEB)

    Willgeroth, F. [Lenkungsausschuss BMS (Germany); Universitaetsfrauenklinik Innenstadt, Muenchen (Germany); Baumann, M.; Blaser, D.; Froschauer, S.; Kaeaeb, V.; Stich, V.; Thomaschewski, S.; Walter, D. [Kassenaerztliche Vereinigung Bayern (Germany); Crispin, A. [Klinikum Grosshadern der LMU Muenchen, Institut fuer Medizinische Informationsverarbeitung (Germany); Waal, J. de; Heywang-Koebrunner, S.; Rothe, R. [Lenkungsausschuss BMS (Germany); Hoelzel, D. [Lenkungsausschuss BMS (Germany); Klinikum Grosshadern der LMU Muenchen, Institut fuer Medizinische Informationsverarbeitung (Germany)

    2005-03-01

    In Bavaria since the 1st April 2003 we have been conducting a high quality mammography-screening carried out in individual practises (BMS). We have used the European and the S 3 guidelines. The best diagnosis is an early diagnosis of the breast carcinoma to save human life. Because of this and the high mortality rate due to this disease it is essential to have a mammogram screening program. There is no single one ideal way of constructing a screening program, it is always based on compromise within the particular health care-systems. Arising problems cannot be avoided, it is only possible when all parties work closely together that the BMS works properly. (orig.) [German] In Bayern laeuft seit dem 01.04.2003 ein qualitaetsgesichertes, flaechendeckendes Mammographiescreening mit dezentralem Charakter (BMS). Zugrunde liegen die Empfehlungen der European Guidelines sowie der S-3-Leitlinie. Die Vorverlegung der Diagnostik ist beim Mammakarzinom bis heute die effektivste Moeglichkeit, um das Leben von Frauen zu retten, die an diesem Krebs erkrankt sind. Daraus und aufgrund der hohen Mortalitaetsrate dieser Erkrankung leitet sich die Notwendigkeit eines Screeningprogramms ab. Dessen Aufbau kann unterschiedlich sein, denbesten Weg gibt es nicht; es wird sich immer eine Kompromissloesung ergeben, die sehr stark vom jeweiligen Gesundheitssystem beeinflusst wird. Auftretende Probleme sind vielschichtig. Nur durch gemeinsame Anstrengungen aller Beteiligten liess sich das Bayerische Mammographiescreening installieren. (orig.)

  7. Influence of breast compression pressure on the performance of population-based mammography screening.

    Science.gov (United States)

    Holland, Katharina; Sechopoulos, Ioannis; Mann, Ritse M; den Heeten, Gerard J; van Gils, Carla H; Karssemeijer, Nico

    2017-11-28

    In mammography, breast compression is applied to reduce the thickness of the breast. While it is widely accepted that firm breast compression is needed to ensure acceptable image quality, guidelines remain vague about how much compression should be applied during mammogram acquisition. A quantitative parameter indicating the desirable amount of compression is not available. Consequently, little is known about the relationship between the amount of breast compression and breast cancer detectability. The purpose of this study is to determine the effect of breast compression pressure in mammography on breast cancer screening outcomes. We used digital image analysis methods to determine breast volume, percent dense volume, and pressure from 132,776 examinations of 57,179 women participating in the Dutch population-based biennial breast cancer screening program. Pressure was estimated by dividing the compression force by the area of the contact surface between breast and compression paddle. The data was subdivided into quintiles of pressure and the number of screen-detected cancers, interval cancers, false positives, and true negatives were determined for each group. Generalized estimating equations were used to account for correlation between examinations of the same woman and for the effect of breast density and volume when estimating sensitivity, specificity, and other performance measures. Sensitivity was computed using interval cancers occurring between two screening rounds and using interval cancers within 12 months after screening. Pair-wise testing for significant differences was performed. Percent dense volume increased with increasing pressure, while breast volume decreased. Sensitivity in quintiles with increasing pressure was 82.0%, 77.1%, 79.8%, 71.1%, and 70.8%. Sensitivity based on interval cancers within 12 months was significantly lower in the highest pressure quintile compared to the third (84.3% vs 93.9%, p = 0.034). Specificity was lower in the

  8. Imaging characteristics of different mammographic screens.

    Science.gov (United States)

    Kuhn, H; Knüpfer, W

    1992-01-01

    A study of mammography systems with green-emitting screens was conducted to determine how the image quality parameters (apart from dose requirement), such as modulation transfer function (MTF) and Wiener spectrum (WS), depend on the dye content of the compound and coating weight of the screen. In addition, the contribution to total noise of the individual components, i.e., film, screen, and quantum noise, was studied. The quantities derived from MTF and WS, namely detective quantum efficiency (DQE) and noise equivalent quanta (NEQ), were also investigated in regard to their dose dependency. It can be demonstrated that the MTF of the screens becomes more favorable when the dye content is increased, while noise is not significantly affected. This suggests the use of a mammography screen capable of greater detail recognition, requiring at least double the dose of today's conventional systems with approximately 80 microGy system dose. On the other hand, the manufacture of a screen with about 60% of the dose of the conventional system is possible with very little loss in image quality. For the systems in common use today (80 microGy), quantum noise represents a considerable share of the total noise at low spatial frequencies, whereas in high spatial frequencies, the graininess of the film dominates quantum noise and screen structure.

  9. Breast density as indicator for the use of mammography or MRI to screen women with familial risk for breast cancer (FaMRIsc: a multicentre randomized controlled trial

    Directory of Open Access Journals (Sweden)

    Saadatmand Sepideh

    2012-10-01

    Full Text Available Abstract Background To reduce mortality, women with a family history of breast cancer often start mammography screening at a younger age than the general population. Breast density is high in over 50% of women younger than 50 years. With high breast density, breast cancer incidence increases, but sensitivity of mammography decreases. Therefore, mammography might not be the optimal method for breast cancer screening in young women. Adding MRI increases sensitivity, but also the risk of false-positive results. The limitation of all previous MRI screening studies is that they do not contain a comparison group; all participants received both MRI and mammography. Therefore, we cannot empirically assess in which stage tumours would have been detected by either test. The aim of the Familial MRI Screening Study (FaMRIsc is to compare the efficacy of MRI screening to mammography for women with a familial risk. Furthermore, we will assess the influence of breast density. Methods/Design This Dutch multicentre, randomized controlled trial, with balanced randomisation (1:1 has a parallel grouped design. Women with a cumulative lifetime risk for breast cancer due to their family history of ≥20%, aged 30–55 years are eligible. Identified BRCA1/2 mutation carriers or women with 50% risk of carrying a mutation are excluded. Group 1 receives yearly mammography and clinical breast examination (n = 1000, and group 2 yearly MRI and clinical breast examination, and mammography biennially (n = 1000. Primary endpoints are the number and stage of the detected breast cancers in each arm. Secondary endpoints are the number of false-positive results in both screening arms. Furthermore, sensitivity and positive predictive value of both screening strategies will be assessed. Cost-effectiveness of both strategies will be assessed. Analyses will also be performed with mammographic density as stratification factor. Discussion Personalized breast cancer screening

  10. Screening mammography. A missed clinical opportunity? Results of the NCI [National Cancer Institute] Breast Cancer Screening Consortium and national health interview survey studies

    International Nuclear Information System (INIS)

    Anon.

    1990-01-01

    Data from seven studies sponsored by the National Cancer Institute (NCI) were used to determine current rates of breast cancer screening and to identify the characteristics of and reasons for women not being screened. All seven studies were population-based surveys of women aged 50 to 74 years without breast cancer. While over 90% of non-Hispanic white respondents had regular sources of medical care, 46% to 76% had a clinical breast examination within the previous year, and only 25% to 41% had a mammogram. Less educated and poorer women had fewer mammograms. The two most common reasons women gave for never having had a mammogram were that they did not known they needed it and that their physician had not recommended it. Many physicians may have overlooked the opportunity to recommend mammography for older women when performing a clinical breast examination and to educate their patients about the benefit of screening mammography

  11. Effectiveness of a Mobile Mammography Program.

    Science.gov (United States)

    Stanley, Elizabeth; Lewis, Madelene C; Irshad, Abid; Ackerman, Susan; Collins, Heather; Pavic, Dag; Leddy, Rebecca J

    2017-12-01

    Mobile mammography units have increasingly been used to address patient health care disparities; however, there are limited data comparing mobile units to stationary sites. This study aims to evaluate the characteristics of women who underwent mammography screening in a mobile unit versus those who underwent mammography screening at a cancer center. In this retrospective study, we analyzed all screening mammography examinations performed in a mobile unit in 2014 (n = 1433 examinations). For comparison, we randomized and reviewed an equivalent number of screening mammography examinations performed at our cancer center in 2014 (n = 1434 examinations). BI-RADS assessment, adherence to follow-up, biopsies performed, cancer detection rate, and sociodemographic variables were recorded. An independent-samples t test was conducted to identify potential differences in age between cancer center patients and mobile unit patients. Chi-square analyses were used to test for associations between location and factors such as health insurance, race, marital status, geographic area, adherence to screening guidelines, recall rate, adherence to follow-up, and cancer detection rates. Patients visiting our cancer center (mean = 57.74 years; SD = 10.55) were significantly older than those visiting the mobile unit (mean = 52.58 years; SD = 8.19; p mobile van (cancer center = 3.70%, mobile unit = 38.73%). There was a significant association between screening location and patient race (χ 2 = 118.75, p mobile unit = 33.30%), more black patients being screened in the mobile van (cancer center = 49.30%, mobile unit = 54.15%), and more Hispanic patients being screened in the mobile van (cancer center = 1.05%, mobile unit = 6.77%). There was a significant association between location and patient marital status (χ 2 = 135.61, p mobile unit = 38.31%), more single patients screened in the mobile van (cancer center = 25.17%, mobile unit = 34.47%), and more widowed patients being screened at the

  12. Update on new technologies in digital mammography

    Directory of Open Access Journals (Sweden)

    Patterson SK

    2014-08-01

    Full Text Available Stephanie K Patterson, Marilyn A Roubidoux Division of Breast Imaging, Department of Radiology, University of Michigan Health System, Ann Arbor, MI, USA Abstract: Despite controversy regarding mammography's efficacy, it continues to be the most commonly used breast cancer-screening modality. With the development of digital mammography, some improved benefit has been shown in women with dense breast tissue. However, the density of breast tissue continues to limit the sensitivity of conventional mammography. We discuss the development of some derivative digital technologies, primarily digital breast tomosynthesis, and their strengths, weaknesses, and potential patient impact. Keywords: screening mammography, breast cancer, contrast media, digital breast tomosynthesis

  13. High-contrast mammography with a moving grid: assessment of clinical utility

    International Nuclear Information System (INIS)

    Sickles, E.A.; Weber, W.N.

    1986-01-01

    Mammography techniques using moving grids produce superior breast images in many patients but result in increased radiation dose. This prospective controlled study of 1000 unselected screen-film mammography patients identifies a subset of women who are most likely to benefit from higher-dose grid-assisted techniques. In approximately 60% of the patients, the increased contrast of grid films produced a noticeable improvement in overall image quality. In only 20% of cases did this translate into clinically useful information, however, usually resulting in an increased level of confidence in interpretation. In virtually all the cases in which grid images aided mammographic diagnosis, the patients were women having more than 50% dense fibroglandular tissue or compressed breast thickness greater than 6 cm (only 37% of the study population). We suggest that the use of grid techniques be restricted to patients with such dense or thick breasts, because only in these women can the increase in radiation dose be justified

  14. Evidence-based information on mammography screening in Austria--reality or more pie in the sky?

    Science.gov (United States)

    Rásky, É; Groth, S

    2013-03-01

    Health literacy is gaining increasing importance in prevention and health care. This is the case for patients and for health-care professionals. Information and risk communication should comply with defined criteria and strengthen health literacy as they are a prerequisite for informed decision making. In this study, we analyse the content of the printed information material (brochures and pamphlets) on mammography screening for consumers that were distributed in Austria in 2011. The evaluation of the 11 brochures shows that the content does not comply with the prerequisites for informed decision making. Since the last study - published in 2004 - the situation has only slightly improved. The authors reemphasise the need for a targeted multimodal information campaign. This is particularly important as a systematic national mammography screening program in compliance with the guidelines of the European Commission will be introduced in Austria in 2013. © Georg Thieme Verlag KG Stuttgart · New York.

  15. Meta-analysis of breast cancer mortality benefit and overdiagnosis adjusted for adherence: improving information on the effects of attending screening mammography

    Science.gov (United States)

    Jacklyn, Gemma; Glasziou, Paul; Macaskill, Petra; Barratt, Alexandra

    2016-01-01

    Background: Women require information about the impact of regularly attending screening mammography on breast cancer mortality and overdiagnosis to make informed decisions. To provide this information we aimed to meta-analyse randomised controlled trials adjusted for adherence to the trial protocol. Methods: Nine screening mammography trials used in the Independent UK Breast Screening Report were selected. Extending an existing approach to adjust intention-to-treat (ITT) estimates for less than 100% adherence rates, we conducted a random-effects meta-analysis. This produced a combined deattenuated prevented fraction and a combined deattenuated percentage risk of overdiagnosis. Results: In women aged 39–75 years invited to screen, the prevented fraction of breast cancer mortality at 13-year follow-up was 0.22 (95% CI 0.15–0.28) and it increased to 0.30 (95% CI 0.18–0.42) with deattenuation. In women aged 40–69 years invited to screen, the ITT percentage risk of overdiagnosis during the screening period was 19.0% (95% CI 15.2–22.7%), deattenuation increased this to 29.7% (95% CI 17.8–41.5%). Conclusions: Adjustment for nonadherence increased the size of the mortality benefit and risk of overdiagnosis by up to 50%. These estimates are more appropriate when developing quantitative information to support individual decisions about attending screening mammography. PMID:27124337

  16. Technical and dosimetric aspects of quality control in mammography

    International Nuclear Information System (INIS)

    Zoetelief, J.; Wit, N.J.P. de; Broerse, J.J.

    1989-01-01

    Before screening programmes using mammography are implemented, a cost benefit analysis has to be made and quality-control programme for the technical and dosimetric aspects adopted, including daily checks on film processing and total mammography procedure (radiography of a reference phantom, for which the average density, limiting value ± 0.20%, and focal charge is determined and which allows assessment of physical image quality) The installation of a MAs meter is essential for daily checks and can be used for determination of absorbed dose. Accurate determination of tube voltage (limiting value ±0.5 kV) is essential in regard to absorbed dose variations. Focal spot size should be measured rather than relying on the value specified by the manufacturer. The determination of the focal charge (mAs) value for actual radiographs of female breasts combined with a measurement of compressed breast thickness provides information on absorbed dose values for actual radiographs. An approximately 50 mm thick poly(methyl methacrylate) phantom can be used for determination of absorbed dose in mammography. (author)

  17. Consensus review of discordant findings maximizes cancer detection rate in double-reader screening mammography: Irish National Breast Screening Program experience.

    Science.gov (United States)

    Shaw, Colette M; Flanagan, Fidema L; Fenlon, Helen M; McNicholas, Michelle M

    2009-02-01

    To assesses consensus review of discordant screening mammography findings in terms of its sensitivity, safety, and effect on overall performance in the first 6 years of operation of the Irish National Breast Screening Program (NBSP). Women who participated in the Irish NBSP gave written informed consent for use of their data for auditing purposes. Local ethics committee approval was obtained. The study population consisted of women who participated in the Irish NBSP and underwent initial screening mammography at one of the two screening centers serving the eastern part of Ireland between 2000 and 2005. Independent double reading of mammograms was performed. When the readers disagreed regarding referral, the case was reviewed by a consensus panel. Of the 128 569 screenings performed, 1335 (1%) were discussed by consensus. Of the 1335 cases discussed by consensus, 606 (45.39%) were recalled for further assessment. This resulted in an overall recall rate of 4.41%. In those recalled to assessment, 71 cases of malignant disease were diagnosed (ductal carcinoma in situ, n = 24; invasive cancer, n = 47). The remaining 729 patients were returned to biennial screening. Of these 729 patients, seven had false-negative findings that were identified in the subsequent screening round. Use of the highest reader recall method, in which a patient is recalled if her findings are deemed abnormal by either reader, could potentially increase the cancer detection rate by 0.6 per 1000 women screened but would increase the recall rate by 12.69% and the number of false-positive findings by 15.37%. The consensus panel identified 71 (7.33%) of 968 cancers diagnosed. Consensus review substantially reduced the number of cases recalled and was associated with a low false-negative rate.

  18. Organization and standards of screening and diagnostic mammography

    International Nuclear Information System (INIS)

    Linderbraten, L.D.; Chikirdin, Eh.G.; Rozhkova, N.I.

    1999-01-01

    Problem of organizing and standards of the reference and diagnostic mammography in our country is discussed. Attention is paid to the terminology, accreditation of mammographic establishments and specialists, specifications of equipment, image quality, mammography results processing, radiation doses [ru

  19. Mammography

    International Nuclear Information System (INIS)

    1975-01-01

    This patent reveals a method and instrument for the detection and registration of breast cancer with the aid of X-radiation, i.e. mammography. The breast is irradiated with soft X-rays whereby the radiation beam is scanned with a moving 'stripform' screen and whereby the picture from the 'stripform' screen is recorded by a television camera that moves simultaneously with the strip. The image is then projected on a monitor

  20. Photographic and energy spectral evaluation of mammography

    International Nuclear Information System (INIS)

    Chiyasu, Shikibu; Ise, Toshihide; Kato, Isao; Asakawa, Yoshihisa; Nakamae, Haruo

    1980-01-01

    The combination of molybdenium anode X-ray tube (with a beryllium window and 0.03 mm molybdenium filter) and a single high resolution intensifying screen (rare earth phosphors) with a green-sensitive single emulsion film is regarded as a very useful and optimum system for mammography. In order to find the optimum exposure condition in this system that we investigated the transmission properties of the mammographic cassette, the intensifying screen and the specimen of breast. We examined four cassettes by the contrast (0.1/0.5 mm aluminium), the visibility of small particles (Mg 2 SiO 4 , 150 -- 600 mu m diameter) by five observers and dose measurements using mammographic phantom, Kodak Min-R screen and Fuji RX-M film. We measured the transmission photon spectra by using pure germanium detector through tumor and normal glandular tissue of breast cancer (3.5 kg weight, 6.5 cm, thickness and 1.0 cm tumor diameter) after surgery. We examined the relationship between the contrast and the transmission photon spectra of macro-specimen of breast cancer (fixation in 10% folmalin solution). Then we selected the phantom materials for mammography which have the same property as the specimen of cancer in the transmission spectra. From these results, the low tube voltage (25 kV) technique gives high contrast and good visibility of small particles in this system. Also in the system, the smaller X-ray absorption of cassette (or package) gives higher contrast, better visibility and lower dose. For the phantom materials, ABS resin has almost same transmission property as the measured normal glandular tissue and Lucite is almost same as the measured tumor and glandular from the point of transmission spectra. (author)

  1. Measurement of half-value layer in mammography

    CERN Document Server

    Yagi, H; Saruwatari, R; Doi, N; Yamane, E

    2003-01-01

    The half-value layer (HVL) of an X-ray beam for film-screen mammography is considered an important parameter for image quality and patient dose. Thus, HVL must be measured in accordance with The Manual of Accuracy for Mammography printed by the Japanese Society of Radiological Technology. The manual prescribes exactly the geometry of measurement, chamber position of measurement in the field, selection of chamber, and so on. However, the measurement of HVL is difficult in the actual clinical setting. This study examined the results of failure to perform the measurement of HVL in accordance with the manual for measuring HVL in the clinical setting. The investigation indicated that serious problems do not arise when measuring HVL for routine quality control even if the chamber in the field is not always set according to the manual and if a chamber for radiotherapy or diagnosis is used that is not recommended for soft X-ray by the manual. (author)

  2. Balancing sensitivity and specificity: sixteen year's of experience from the mammography screening programme in Copenhagen, Denmark

    DEFF Research Database (Denmark)

    Utzon-Frank, Nicolai; Vejborg, Ilse; von Euler-Chelpin, My Catarina

    2011-01-01

    To report on sensitivity and specificity from 7 invitation rounds of the organised, population-based mammography screening programme started in Copenhagen, Denmark, in 1991, and offered biennially to women aged 50-69. Changes over time were related to organisation and technology....

  3. Final Technical Report. A critical evaluation of patent doses in screening mammography

    International Nuclear Information System (INIS)

    Hintenlang, David E.

    2004-01-01

    This project was designed to develop tools that would permit an accurate assessment of the patient doses that are received in screening mammography, and to subsequently demonstrate those tools to perform an objective evaluation of patient doses. The project also provides an educational component through the integration of multiple aspects of applied radiological engineering to provide students with realistic applications of many of the theoretical principles that are studied as part of their graduate curriculum

  4. Lead iodide films as X-ray sensors tested in the mammography energy region

    International Nuclear Information System (INIS)

    Condeles, J.F.; Ghilardi Netto, T.; Mulato, M.

    2007-01-01

    We present an alternative method for the deposition of thin films of lead iodide (PbI 2 ), which is a promising semiconductor candidate for applications in medical digital radiography. The spray pyrolysis technique enables the fabrication of thick films with a deposition rate of about 3.3 As -1 . We investigate the influence of the main deposition parameters on the final properties of the films. They were substrate temperature from 150 up to 270 o C and nozzle-spray distance to substrate from 13.0 to 16.5 cm. The films were mainly investigated using X-ray diffraction (XRD), Atomic Force Microscopy (AFM), and Photoluminescence (PL) spectroscopy. Also, electrical characterizations were made in the dark as a function of temperature, and with the samples submitted to X-ray exposures in the energy range of mammography diagnosis

  5. Position paper: recommendations for a digital mammography quality assurance program V4.0.

    Science.gov (United States)

    Heggie, J C P; Barnes, P; Cartwright, L; Diffey, J; Tse, J; Herley, J; McLean, I D; Thomson, F J; Grewal, R K; Collins, L T

    2017-09-01

    In 2001 the ACPSEM published a position paper on quality assurance in screen film mammography which was subsequently adopted as a basis for the quality assurance programs of both the Royal Australian and New Zealand College of Radiologists (RANZCR) and of BreastScreen Australia. Since then the clinical implementation of digital mammography has been realised and it has become evident that existing screen-film protocols were not appropriate to assure the required image quality needed for reliable diagnosis or to address the new dose implications resulting from digital technology. In addition, the advantages and responsibilities inherent in teleradiology are most critical in mammography and also need to be addressed. The current document is the result of a review of current overseas practice and local experience in these areas. At this time the technology of digital imaging is undergoing significant development and there is still a lack of full international consensus about some of the detailed quality control (QC) tests that should be included in quality assurance (QA) programs. This document describes the current status in digital mammography QA and recommends test procedures that may be suitable in the Australasian environment. For completeness, this document also includes a review of the QA programs required for the various types of digital biopsy units used in mammography. In the future, international harmonisation of digital quality assurance in mammography and changes in the technology may require a review of this document. Version 2.0 represented the first of these updates and key changes related to image quality evaluation, ghost image evaluation and interpretation of signal to noise ratio measurements. In Version 3.0 some significant changes, made in light of further experience gained in testing digital mammography equipment were introduced. In Version 4.0, further changes have been made, most notably digital breast tomosynthesis (DBT) testing and QC have

  6. Three-dimensional dose distribution in contrast-enhanced digital mammography using Gafchromic XR-QA2 films: Feasibility study

    International Nuclear Information System (INIS)

    Hwang, Yi-Shuan; Lin, Yu-Ying; Cheung, Yun-Chung; Tsai, Hui-Yu

    2014-01-01

    This study was aimed to establish three-dimensional dose distributions for contrast-enhanced digital mammography (CEDM) using self-developed Gafchromic XR-QA2 films. Dose calibration and distribution evaluations were performed on a full-field digital mammography unit with dual energy (DE) contrast-enhanced option. Strategy for dose calibration of films in the DE mode was based on the data obtained from common target/filter/kVp combinations used clinically and the dose response model modified from Rampado's model. Dose derived from films were also verified by measured data from an ionization chamber. The average difference of dose was 8.9% in the dose range for clinical uses. Three-dimensional dose distributions were estimated using triangular acrylic phantom equipped with the mammography system. Five pieces of film sheets were separately placed between the acrylic slabs to evaluate the dose distribution at different depths. After normalizing the dose in each pixel to the maximum dose at the top-center position of the acrylic, normalized dose distribution for transverse, coronal and sagittal planes, could thus be obtained. The depth dose distribution evaluated in this study may further serve as a reference for evaluating the patient glandular dose at different depths based on the entrance exposure information. - Highlights: • CEDM techniques can enhance contrast uptake areas and suppress background tissue. • Dose for the dual-energy acquisition is about 20% higher than standard mode. • A new method is proposed to estimate the 3D dose distribution in dual-energy CEDM. • Depth of normalized dose ratio of 0.5 is less than but near 1 cm in the DE mode

  7. Radiogenic breast cancer risk and mammography

    International Nuclear Information System (INIS)

    Jayaprakash, Shobha; Nair, C.P.R.; Rao, B.S.; Sawant, S.G.

    2001-01-01

    There is a general concern that the risks from mammography screening in inducting radiogenic breast cancer may outweigh the possible benefits to be derived from it. A review of epidemiological, case-control and cohort studies of radiogenic breast cancer, age-specific incidence and dose and dose-rate relationship reveals that such a fear is unfounded. The dose to the breast tissues in a quality assured mammography screening programme falls far below the levels that were observed to produce increased relative risk. The age-specific incidence rates also indicate that the need for mammography is for the women of age at which the relative risk is minimum

  8. The self-referred mammography patient

    International Nuclear Information System (INIS)

    Reynolds, H.E.; Jackson, V.P.

    1990-01-01

    This paper compares the demographics, knowledge, and attitudes of women who refer themselves for screening mammography with those who undergo mammography on the advice of their physicians. Four hundred eighty-five consecutive mammography patients (437 doctor preferred [DR], 48 self-referred [SR]) completed a survey during their mammography appointment. The sample population contained a wide range of socioeconomic groups. While similar in age, race, and employment status to DR patients, SR patients were significantly more likely to have a family income of more than 30,000 per year, be college graduates, and report that they were in good or excellent health

  9. Mammography-based screening program: preliminary results from a first 2-year round in a Brazilian region using mobile and fixed units

    Directory of Open Access Journals (Sweden)

    Haikel Raphael

    2012-10-01

    Full Text Available Abstract Background Breast cancer is the most frequently diagnosed cancer and the leading cause of cancer deaths among women worldwide. The use of mobile mammography units to offer screening to women living in remote areas is a rational strategy to increase the number of women examined. This study aimed to evaluate results from the first 2 years of a government-organized mammography screening program implemented with a mobile unit (MU and a fixed unit (FU in a rural county in Brazil. The program offered breast cancer screening to women living in Barretos and the surrounding area. Methods Based on epidemiologic data, 54 238 women, aged 40 to 69 years, were eligible for breast cancer screening. The study included women examined from April 1, 2003 to March 31, 2005. The chi-square test and Bonferroni correction analyses were used to evaluate the frequencies of tumors and the importance of clinical parameters and tumor characteristics. Significance was set at p Results Overall, 17 964 women underwent mammography. This represented 33.1% of eligible women in the area. A mean of 18.6 and 26.3 women per day were examined in the FU and MU, respectively. Seventy six patients were diagnosed with breast cancer (41 (54% in the MU. This represented 4.2 cases of breast cancer per 1000 examinations. The number of cancers detected was significantly higher in women aged 60 to 69 years than in those aged 50 to 59 years (p Conclusions Preliminary results indicate that this mammography screening program is feasible for implementation in a rural Brazilian territory and favor program continuation.

  10. The outcome of a quality-controlled mammography screening program: Experience from a population-based study in Taiwan

    Directory of Open Access Journals (Sweden)

    Huay-Ben Pan

    2014-10-01

    Conclusion: From the outcome review of this national mammography screening, there is still room to ameliorate our performance through comprehensive and continued education, to improve the competence of cancer detection and decrease false negative (FN cases.

  11. Screening methods(clinical breast examination and mammography to detect breast cancer in women aged 40–49 years

    Directory of Open Access Journals (Sweden)

    Navneet Takkar

    2017-01-01

    Conclusion: The study findings are in agreement with the recommendations of the World Health Organization, US preventive task force and UK guidelines that recommend screening mammography in women starting at 50 years.

  12. Impact of organised mammography screening on breast cancer mortality in a case–control and cohort study

    Science.gov (United States)

    Heinävaara, Sirpa; Sarkeala, Tytti; Anttila, Ahti

    2016-01-01

    Background: The usefulness of case–control studies has been questioned. Our aim was to evaluate the long-term effect of screening on breast cancer mortality within the population-based mammography programme in Finland using a case–control design, and to compare the analyses with the earlier cohort study. Methods: The cases were women invited to screening, diagnosed and died from breast cancer in 1992–2011 while being 50–84 years at death. We chose 10 controls for each case with non-restrictive eligibility criteria. Our data included 1907 cases and 18 978 matched controls. We analysed associations between the screening participation and the risk of breast cancer death using the conditional Cox proportional hazards model. The effect estimates were corrected for self-selection bias. Results: An overall effect of screening was 0.67 (95% confidence interval (CI): 0.49–0.90), and that remained unchanged over time. Analyses with matching criteria comparable to the cohort study yielded an effect (0.70, 95% CI: 0.49–1.00) in 1992–2003 similar to that of the previous cohort analysis (0.72, 95% CI: 0.56–0.88). Conclusions: Organised mammography screening decreases mortality from breast cancer by 33% among the participants. If made comparable, a case–cohort study can yield effect estimates similar to a cohort study. PMID:27010748

  13. Development of an imaging-planning program for screen/film and computed radiography mammography for breasts with short chest wall to nipple distance.

    Science.gov (United States)

    Dong, S L; Su, J L; Yeh, Y H; Chu, T C; Lin, Y C; Chuang, K S

    2011-04-01

    Imaging breasts with a short chest wall to nipple distance (CWND) using a traditional mammographic X-ray unit is a technical challenge for mammographers. The purpose of this study is the development of an imaging-planning program to assist in determination of imaging parameters of screen/film (SF) and computed radiography (CR) mammography for short CWND breasts. A traditional mammographic X-ray unit (Mammomat 3000, Siemens, Munich, Germany) was employed. The imaging-planning program was developed by combining the compressed breast thickness correction, the equivalent polymethylmethacrylate thickness assessment for breasts and the tube loading (mAs) measurement. Both phantom exposures and a total of 597 exposures were used for examining the imaging-planning program. Results of the phantom study show that the tube loading rapidly decreased with the CWND when the automatic exposure control (AEC) detector was not fully covered by the phantom. For patient exposures with the AEC fully covered by breast tissue, the average fractional tube loadings, defined as the ratio of the predicted mAs using the imaging-planning program and mAs of the mammogram, were 1.10 and 1.07 for SF and CR mammograms, respectively. The predicted mAs values were comparable to the mAs values, as determined by the AEC. By applying the imaging-planning program in clinical practice, the experiential dependence of the mammographer for determination of the imaging parameters for short CWND breasts is minimised.

  14. Reproducibility of Mammography Units, Film Processing and Quality Imaging

    International Nuclear Information System (INIS)

    Gaona, Enrique

    2003-01-01

    The purpose of this study was to carry out an exploratory survey of the problems of quality control in mammography and processors units as a diagnosis of the current situation of mammography facilities. Measurements of reproducibility, optical density, optical difference and gamma index are included. Breast cancer is the most frequently diagnosed cancer and is the second leading cause of cancer death among women in the Mexican Republic. Mammography is a radiographic examination specially designed for detecting breast pathology. We found that the problems of reproducibility of AEC are smaller than the problems of processors units because almost all processors fall outside of the acceptable variation limits and they can affect the mammography quality image and the dose to breast. Only four mammography units agree with the minimum score established by ACR and FDA for the phantom image

  15. Supplementary methods in breast cancer screening: ultrasonography and magnetic resonance tomography of the breast; Mammasonographie und Magnetresonanz-Mammographie als ergaenzende Methoden im Mammographiescreening

    Energy Technology Data Exchange (ETDEWEB)

    Delorme, S. [Deutsches Krebsforschungszentrum Heidelberg (Germany). Abt. fuer Onkologische Diagnostik und Therapie

    2001-04-01

    Ultrasonography and magnetic resonance (MR) tomography are helpful tools to evaluate unclear lesions found at screening mammography. Ultrasound is particularly useful to prove the presence of a cyst or to further examine unclear, asymmetrical densities. With MR mammography, carcinomas can be found even when X-ray mammography or ultrasonography are limited due to diffuse, benign, proliferative changes. Ultrasound guidance has greatly facilitated core needle biopsy for suspicious lesions. Additionally, approved devices for MR-guided biopsy are commercially available. As a primary screening tool, ultrasound or MR mammography may be used only in women who are positive for BRCA-1 or BRCA-2 mutations or who are otherwise at high risk for breast cancer. (orig.) [German] Sonographie und Magnetresonanz-Mammographie koennen zur Abklaerung unklarer Befunde eingesetzt werden, die im Rahmen des Mammographiescreenings auffallen. Die Mammosonographie eignet sich besonders zum Nachweis von Zysten und zur Abklaerung unklarer Dichte-Asymmetrien. Mit der Magnetresonanz-Mammographie koennen Karzinome auch dann nachgewiesen werden, wenn die Untersuchungsbedingungen fuer die Roentgenmammographie oder die Sonographie aufgrund einer Mastopathie unguenstig sind. Bei der differenzialdiagnostischen Abklaerung von Herdbefunden hat die Moeglichkeit der sonographischen Fuehrung einer Stanz- oder Vakuumbiopsie das Verfahren wesentlich vereinfacht. Fuer die MR-gesteuerte Biopsie sind inzwischen zugelassene Fuehrungshilfen kommerziell erhaeltlich. Als primaere Screeningmethode kommen sowohl die Sonographie als auch die Magnetresonanz-Mammographie nur fuer wenige Frauen in Frage, in der Regel bei nachgewiesenen BRCA-1- oder BRCA-2-Mutationen oder bei sonstiger Brustkrebsdisposition. (orig.)

  16. Informed Choice in the German Mammography Screening Program by Education and Migrant Status: Survey among First-Time Invitees.

    Directory of Open Access Journals (Sweden)

    Eva-Maria Berens

    Full Text Available Breast cancer is the most prevalent cancer among women and mammography screening programs are seen as a key strategy to reduce breast cancer mortality. In Germany, women are invited to the population-based mammography screening program between ages 50 to 69. It is still discussed whether the benefits of mammography screening outweigh its harms. Therefore, the concept of informed choice comprising knowledge, attitude and intention has gained importance. The objective of this observational study was to assess the proportion of informed choices among women invited to the German mammography screening program for the first time. A representative sample of 17,349 women aged 50 years from a sub-region of North Rhine Westphalia was invited to participate in a postal survey. Turkish immigrant women were oversampled. The effects of education level and migration status on informed choice and its components were assessed. 5,847 (33.7% women responded to the postal questionnaire of which 4,113 were used for analyses. 31.5% of the women had sufficient knowledge. The proportion of sufficient knowledge was lower among immigrants and among women with low education levels. The proportion of women making informed choices was low (27.1%, with similar associations with education level and migration status. Women of low (OR 2.75; 95% CI 2.18-3.46 and medium education level (OR 1.49; 95% CI 1.27-1.75 were more likely to make an uninformed choice than women of high education level. Turkish immigrant women had the greatest odds for making an uninformed choice (OR 5.30, 95% CI 1.92-14.66 compared to non-immigrant women. Other immigrant women only had slightly greater odds for making an uninformed choice than non-immigrant women. As immigrant populations and women with low education level have been shown to have poor knowledge, they need special attention in measures to increase knowledge and thus informed choices.

  17. A novel case-control design to estimate the extent of over-diagnosis of breast cancer due to organised population-based mammography screening.

    Science.gov (United States)

    Beckmann, Kerri R; Lynch, John W; Hiller, Janet E; Farshid, Gelareh; Houssami, Nehmat; Duffy, Stephen W; Roder, David M

    2015-03-15

    Debate about the extent of breast cancer over-diagnosis due to mammography screening has continued for over a decade, without consensus. Estimates range from 0 to 54%, but many studies have been criticized for having flawed methodology. In this study we used a novel study design to estimate over-diagnosis due to organised mammography screening in South Australia (SA). To estimate breast cancer incidence at and following screening we used a population-based, age-matched case-control design involving 4,931 breast cancer cases and 22,914 controls to obtain OR for yearly time intervals since women's last screening mammogram. The level of over-diagnosis was estimated by comparing the cumulative breast cancer incidence with and without screening. The former was derived by applying ORs for each time window to incidence rates in the absence of screening, and the latter, by projecting pre-screening incidence rates. Sensitivity analyses were undertaken to assess potential biases. Over-diagnosis was estimated to be 8% (95%CI 2-14%) and 14% (95%CI 8-19%) among SA women aged 45 to 85 years from 2006-2010, for invasive breast cancer and all breast cancer respectively. These estimates were robust when applying various sensitivity analyses, except for adjustment for potential confounding assuming higher risk among screened than non-screened women, which reduced levels of over-diagnosis to 1% (95%CI 5-7%) and 8% (95%CI 2-14%) respectively when incidence rates for screening participants were adjusted by 10%. Our results indicate that the level of over-diagnosis due to mammography screening is modest and considerably lower than many previous estimates, including others for Australia. © 2014 UICC.

  18. Influence of the radiographer on the pain felt during mammography

    International Nuclear Information System (INIS)

    Goethem, M. van; Verslegers, I.; Biltjes, I.; De Schepper, A.; Mortelmans, D.; Bruyninckx, E.; Hove, E. Van

    2003-01-01

    Mammography is the only useful examination in screening for breast cancer. Mortality from breast cancer can be reduced if women go regularly for a screening mammography. Moreover, it is still the key examination in diagnosis of breast diseases and in the follow-up of patients treated for breast cancer. Pain with mammography can deter women from going for regular screening or follow-up; therefore, it is important to reduce pain experience or discomfort from mammography. In this study we evaluate the impact of the ''radiographer'' on the pain risk during mammography by analysing questionnaires filled in by women and radiographers. Study results reveal that the opinion of the radiographer, the information and communication during the examination and the number of years of experience are important factors in pain and discomfort experience. The attitude of the radiographer plays an important role in the pain experience. (orig.)

  19. Mammography accreditation program

    Energy Technology Data Exchange (ETDEWEB)

    Wilcox, P.

    1993-12-31

    In the mid-1980`s, the movement toward the use of dedicated mammography equipment provided significant improvement in breast cancer detection. However, several studies demonstrated that this change was not sufficient to ensure optimal image quality at a low radiation dose. In particular, the 1985 Nationwide Evaluation of X-ray Trends identified the wide variations in image quality and radiation dose, even from dedicated units. During this time period, the American Cancer Society (ACS) launched its Breast Cancer Awareness Screening Campaign. However, there were concerns about the ability of radiology to respond to the increased demand for optimal screening examinations that would result from the ACS program. To respond to these concerns, the ACS and the American College of Radiology (ACR) established a joint committee on mammography screening in 1986. After much discussion, it was decided to use the ACR Diagnostic Practice Accreditation Program as a model for the development of a mammography accreditation program. However, some constraints were required in order to make the program meet the needs of the ACS. This voluntary, peer review program had to be timely and cost effective. It was determined that the best way to address these needs would be to conduct the program by mail. Finally, by placing emphasis on the educational nature of the program, it would provide an even greater opportunity for improving mammographic quality. The result of this effort was that, almost six years ago, in May 1987, the pilot study for the ACR Mammography Accreditation Program (MAP) began, and in August of that year, the first applications were received. In November 1987, the first 3-year accreditation certificates were awarded.

  20. Mammography accreditation program

    International Nuclear Information System (INIS)

    Wilcox, P.

    1993-01-01

    In the mid-1980's, the movement toward the use of dedicated mammography equipment provided significant improvement in breast cancer detection. However, several studies demonstrated that this change was not sufficient to ensure optimal image quality at a low radiation dose. In particular, the 1985 Nationwide Evaluation of X-ray Trends identified the wide variations in image quality and radiation dose, even from dedicated units. During this time period, the American Cancer Society (ACS) launched its Breast Cancer Awareness Screening Campaign. However, there were concerns about the ability of radiology to respond to the increased demand for optimal screening examinations that would result from the ACS program. To respond to these concerns, the ACS and the American College of Radiology (ACR) established a joint committee on mammography screening in 1986. After much discussion, it was decided to use the ACR Diagnostic Practice Accreditation Program as a model for the development of a mammography accreditation program. However, some constraints were required in order to make the program meet the needs of the ACS. This voluntary, peer review program had to be timely and cost effective. It was determined that the best way to address these needs would be to conduct the program by mail. Finally, by placing emphasis on the educational nature of the program, it would provide an even greater opportunity for improving mammographic quality. The result of this effort was that, almost six years ago, in May 1987, the pilot study for the ACR Mammography Accreditation Program (MAP) began, and in August of that year, the first applications were received. In November 1987, the first 3-year accreditation certificates were awarded

  1. Scrutinizing screening: a critical interpretive review of primary care provider perspectives on mammography decision-making with average-risk women.

    Science.gov (United States)

    Siedlikowski, Sophia; Ells, Carolyn; Bartlett, Gillian

    2018-01-01

    A decision to undertake screening for breast cancer often takes place within the primary care setting, but current controversies such as overdiagnosis and inconsistent screening recommendations based on evolving evidence render this a challenging process, particularly for average-risk women. Given the responsibility of primary care providers in counseling women in this decision-making process, it is important to understand their thoughts on these controversies and how they manage uncertainty in their practice. To review the perspectives and approaches of primary care providers regarding mammography decision-making with average-risk women. This study is a critical interpretive review of peer-review literature that reports primary care provider perspectives on mammography screening decision-making. Ovid MEDLINE®, Ovid PsycInfo, and Scopus databases were searched with dates from 2002 to 2017 using search terms related to mammography screening, uncertainty, counseling, decision-making, and primary health care providers. Nine articles were included following a review process involving the three authors. Using an inductive and iterative approach, data were grouped into four thematic categories: (1) perceptions on the effectiveness of screening, screening initiation age, and screening frequency; (2) factors guiding primary care providers in the screening decision-making process, including both provider and patient-related factors, (3) uncertainty faced by primary care providers regarding guidelines and screening discussions with their patients; and (4) informed decision-making with average-risk women, including factors that facilitate and hinder this process. The discussion of results addresses several factors about the diversity of perspectives and practices of physicians counseling average-risk women regarding breast cancer screening. This has implications for the challenge of understanding and explaining evidence, what should be shared with average-risk women

  2. Comparison of cumulative false-positive risk of screening mammography in the United States and Denmark

    DEFF Research Database (Denmark)

    Jacobsen, Katja Kemp

    2015-01-01

    INTRODUCTION: In the United States (US), about one-half of women screened with annual mammography have at least one false-positive test after ten screens. The estimate for European women screened ten times biennially is much lower. We evaluate to what extent screening interval, mammogram type......=400,204), between 1991-2012 and 1993-2013, respectively. Model-based cumulative false-positive risks were computed for the entire sample, using two statistical methods (Hubbard Njor) previously used to estimate false-positive risks in the US and Europe. RESULTS: Empirical cumulative risk of at least...... one false-positive test after eight (annual or biennial) screens was 41.9% in BCSC, 16.1% in Copenhagen, and 7.4% in Funen. Variation in screening interval and mammogram type did not explain the differences by country. Using the Hubbard method, the model-based cumulative risks after eight screens...

  3. Readability assessment of internet-based patient education materials related to mammography for breast cancer screening.

    Science.gov (United States)

    AlKhalili, Rend; Shukla, Pratik A; Patel, Ronak H; Sanghvi, Saurin; Hubbi, Basil

    2015-03-01

    The US Department of Health and Human Services (USDHHS) recommends that Internet-based patient education materials (IPEMs) be written below the sixth-grade reading level to target the average American adult. This study was designed to determine the readability of IPEMs regarding mammography for breast cancer screening. Three-hundred mammography-related Web sites were reviewed for IPEMs. Forty-two IPEMs that met the Health on the Net Foundation Code of Conduct were assessed for readability level with four readability indices that use existing algorithms based on word and sentence length to quantitatively analyze Internet sources for language intricacy including the following: Flesch-Kincaid Grade Level (FKGL), Flesch Reading Ease Score (FRES), Simple Measure of Gobbledygook (SMOG), and Gunning Frequency of Gobbledygook (Gunning FOG; GFOG). Results were compared to national recommendations, and intergroup analysis was performed. No IPEMs (0%) regarding mammography were written at or below the sixth-grade reading level, based on FKGL. The mean readability scores were as follows: FRES, 49.04 ± 10.62; FKGL, 10.71 ± 2.01; SMOG, 13.33 ± 1.67; and Gunning FOG, 14.32 ± 2.18. These scores indicate that the readability of mammography IPEMs is written at a "difficult" level, significantly above the recommended sixth-grade reading level (P < .05) determined by the USDHHS. IPEMs related to mammography are written well above the recommended sixth-grade level and likely reflect other IPEMs in diagnostic radiology. Copyright © 2015 AUR. Published by Elsevier Inc. All rights reserved.

  4. Glandular dose and image quality control in mammography facilities with computerized radiography systems; Dose glandular e controle de qualidade da imagem em servicos de mamografia com sistema de radiografia computadorizada

    Energy Technology Data Exchange (ETDEWEB)

    Dantas, Marcelino Vicente de Almeida

    2010-07-01

    Breast cancer is the most common cancer among women, and early detection is critical to its diagnosis and treatment. To date, the most effective method for early detection of breast cancer has been x-ray mammography for which the screen/film (SF) technique has been the gold standard. However, even though SF combinations have been improved and optimized over the years for breast imaging, there are some critical limitations, including a narrow exposure range, image artifacts, film processing problems, and inflexibility in image processing and film management. In recent years, digital mammography has been introduced in cancer screening programmes with the screen/film techniques gradually being phased out. Computed radiography (CR), also commonly known as photostimulable phosphor (PSP) imaging or storage phosphor, employs reusable imaging plates and associated hardware and software to acquire and to display digital projection radiographs. In this work, a protocol model was tested for performing image quality control and average glandular dose (AGD) evaluation in 19 institutions with computed radiography systems for mammography. The protocol was validated through tests at the Laboratorio de Radioprotecao Aplicada a Mamografia (LARAM) from the Centro de Desenvolvimento da Tecnologia Nuclear (CDTN). The image quality visual evaluation of CDMAM phantom showed that 53% of the facilities were able to produce images of excellent quality. Furthermore, the automated evaluation of image quality, using the analyze software cdcom.exe, showed that 57% of the images were considered to be of good quality. The detector linearity test showed that the CR response is very linear, where 95% of facilities evaluated were considered to be compliant. For the image noise was found that only 20% of facilities are in agreement with the parameters established for this test. The average glandular doses, which patients may be getting to perform an examination, were below the action levels

  5. Impact of the digitalisation of mammography on performance parameters and breast dose in the Flemish Breast Cancer Screening Programme

    Energy Technology Data Exchange (ETDEWEB)

    Timmermans, Lore; Hauwere, An de; Bacher, Klaus; Thierens, Hubert [Ghent University, Department of Basic Medical Sciences, QCC-Gent, Ghent (Belgium); Bosmans, Hilde; Lemmens, Kim; Steen, Andre van [University Hospitals Leuven, Department of Radiology, Leuven (Belgium); Bleyen, Luc; Mortier, Griet; Herck, Koen van [Ghent University, Centrum voor Preventie en Vroegtijdige Opsporing van Kanker, Ghent (Belgium); Limbergen, Erik van [Leuvens Universitair Centrum voor Kankerpreventie, Leuven (Belgium); Martens, Patrick [Vroegtijdige Opsporing van Borstklierkanker vzw, Bruges (Belgium)

    2014-08-15

    To investigate the impact of digitalisation on performance parameters and breast dose of the Flemish Breast Cancer Screening Programme. Both computed (CR) and direct radiography (DR) are compared with screen-film mammography (SFM). Data from 975,673 mammographic examinations were collected from units which underwent digitalisation from SFM to CR (41 units) or DR (72 units) in the period 2005-2011. Performance indicators were obtained by consulting the Screening Programme database. Phantom and patient dosimetry data were acquired from the physical technical quality assurance of the programme. Digitalisation induced no significant change in cancer detection rate (CDR), percentage of ductal carcinomas in situ and percentage of breast cancers smaller than 1 cm. A decrease in false-positive results and third readings was observed, which was a time-related observation. After digitalisation, positive predictive value (PPV) increased and recall rates decreased. Compared with SFM, an increase of 30 % in mean glandular dose (MGD) was found for CR, while a similar change in the opposite direction was found for DR. No major differences in performance parameters after digitalisation were found. Transition of SFM to CR resulted in a higher MGD and associated lower detection-over-induction ratio (DIR), while the change to DR induced an improvement of DIR. (orig.)

  6. Impact of the digitalisation of mammography on performance parameters and breast dose in the Flemish Breast Cancer Screening Programme

    International Nuclear Information System (INIS)

    Timmermans, Lore; Hauwere, An de; Bacher, Klaus; Thierens, Hubert; Bosmans, Hilde; Lemmens, Kim; Steen, Andre van; Bleyen, Luc; Mortier, Griet; Herck, Koen van; Limbergen, Erik van; Martens, Patrick

    2014-01-01

    To investigate the impact of digitalisation on performance parameters and breast dose of the Flemish Breast Cancer Screening Programme. Both computed (CR) and direct radiography (DR) are compared with screen-film mammography (SFM). Data from 975,673 mammographic examinations were collected from units which underwent digitalisation from SFM to CR (41 units) or DR (72 units) in the period 2005-2011. Performance indicators were obtained by consulting the Screening Programme database. Phantom and patient dosimetry data were acquired from the physical technical quality assurance of the programme. Digitalisation induced no significant change in cancer detection rate (CDR), percentage of ductal carcinomas in situ and percentage of breast cancers smaller than 1 cm. A decrease in false-positive results and third readings was observed, which was a time-related observation. After digitalisation, positive predictive value (PPV) increased and recall rates decreased. Compared with SFM, an increase of 30 % in mean glandular dose (MGD) was found for CR, while a similar change in the opposite direction was found for DR. No major differences in performance parameters after digitalisation were found. Transition of SFM to CR resulted in a higher MGD and associated lower detection-over-induction ratio (DIR), while the change to DR induced an improvement of DIR. (orig.)

  7. Estimation of patient dose in mammography screening examinations

    International Nuclear Information System (INIS)

    Suzuki, S.; Fujii, S.; Orito, T.; Asada, Y.; Koga, S.; Horita, K.; Kido, C.

    1996-01-01

    Mammography is one of the most effective examinations for detecting breast carcinoma. Although the dose is usually much higher than that in other types of X-ray examination, that is accepted by the patient because for fears of suffering cancer. Benefit of relatively high doses derived from mammographic examinations is considered to well exceed the risk of cancer induction by radiation exposure. The purpose of this study is to investigate patient dose of mammography in Japan by questionnaire sent to 531 institutions selected from whole Japan and direct measurements carried out in 28 hospitals in Aichi Prefecture. The user's guide in mammography published by NCRP and Quality Assurance Program of American College of Radiology were used to assess the exposure and image quality of mammogram. (author)

  8. Breast cancer screening: Evidence of the effect of adjunct ultrasound screening in women with unilateral mammography-negative dense breasts

    Directory of Open Access Journals (Sweden)

    Atoosa Adibi

    2015-01-01

    Full Text Available Background: Patients with the previous history of breast cancer are in risk of contralateral breast cancer. On the other hand, increased breast density is a risk factor for breast cancer and the sensitivity of detecting nonpalpable cancers in screening mammography in radiographically dense breasts is low. The use of ultrasonography in dense breast remains a controversial topic. The purpose of this study was to assess the usefulness of routine ultrasonography in follow-up of women with the previous history of breast cancer and negative mammography but dense breasts. Materials and Methods: In a cross-sectional study, a total of 267 individuals with unilateral postmastectomy mammogram screened and 153 subjects assigned to study. There were 28 subjects with American College of Radiology (ACR breast density 2 and 125 with ACR breast density 3-4, which there was no new finding in their mammogram in comparison to previous studies. We assumed subjects with ACR breast density 3-4 as mammographic Breast Imaging Reporting and Data System (BI-RADS category 0 for malignancy. Standard two-view mammogram was performed for all participants, and breast ultrasound (US examinations were performed by an expert radiologist in radial and anti-radial planes. The data were analyzed using SPSS version 20.0 (SPSS Inc., Chicago, Illinois, USA. Results: The results showed that in subjects with ACR breast density 3-4, when there was no new density in two consecutive mammograms in comparison to previous studies, US also showed no possibility for malignancy (BI-RADS 1-2. And also in subjects with ACR breast density 2, when the mammographic results were BI-RADS 1-2, the US results was the same. Conclusion: Our data indicate that for the detection of breast cancer, sensitivity of US was not greater than mammography in patients with postmastectomy unilateral dense breast if there is not any new density.

  9. Design and image-quality performance of high resolution CMOS-based X-ray imaging detectors for digital mammography

    Science.gov (United States)

    Cha, B. K.; Kim, J. Y.; Kim, Y. J.; Yun, S.; Cho, G.; Kim, H. K.; Seo, C.-W.; Jeon, S.; Huh, Y.

    2012-04-01

    In digital X-ray imaging systems, X-ray imaging detectors based on scintillating screens with electronic devices such as charge-coupled devices (CCDs), thin-film transistors (TFT), complementary metal oxide semiconductor (CMOS) flat panel imagers have been introduced for general radiography, dental, mammography and non-destructive testing (NDT) applications. Recently, a large-area CMOS active-pixel sensor (APS) in combination with scintillation films has been widely used in a variety of digital X-ray imaging applications. We employed a scintillator-based CMOS APS image sensor for high-resolution mammography. In this work, both powder-type Gd2O2S:Tb and a columnar structured CsI:Tl scintillation screens with various thicknesses were fabricated and used as materials to convert X-ray into visible light. These scintillating screens were directly coupled to a CMOS flat panel imager with a 25 × 50 mm2 active area and a 48 μm pixel pitch for high spatial resolution acquisition. We used a W/Al mammographic X-ray source with a 30 kVp energy condition. The imaging characterization of the X-ray detector was measured and analyzed in terms of linearity in incident X-ray dose, modulation transfer function (MTF), noise-power spectrum (NPS) and detective quantum efficiency (DQE).

  10. Should breast cancer survivors be excluded from, or invited to, organised mammography screening programmes?

    Directory of Open Access Journals (Sweden)

    Bucchi Lauro

    2011-10-01

    Full Text Available Abstract Background The prevalence of breast cancer in developed countries has steadily risen over recent decades. Immediate and long-term health needs of patients, including preventive care and screening services, are receiving increasing attention. A question still unresolved is whether breast cancer survivors should receive mammographic surveillance in the clinical or screening setting and, thus, whether they should be excluded from, or invited to, organised mammography screening programmes. The objective of this article is to discuss the many contradictory aspects of this matter. Discussion Problems with mammographic surveillance of breast cancer survivors include: weak evidence of a reduction in mortality; lack of evidence in favour of one setting or the other; lack of evidence-based guidelines for the frequency and duration of surveillance; disproportionate emphasis placed on the first few years post-treatment, probably dictated by surgical and oncological priorities; a variety of screening policies, as these women are permanently or temporarily or partially excluded from many - but not all - organised screening programmes worldwide; an even greater disparity in follow-up protocols used in the clinical setting; a paucity of data on compliance to mammographic surveillance in both settings; and a difficulty in coordinating the roles of health care providers. In the future, the use of mammography in breast cancer survivors will be influenced by the inclusion of women aged > 69 years in organised screening programmes and the implementation of multidisciplinary breast units, and will probably be investigated by research activities on individual risk assessment and risk-tailored screening. In the interim, current problems can be partially alleviated with some technical solutions in screening data recording, patient flows, and care coordination. Summary Mammographic surveillance of breast cancer survivors is situated at the crossroads of numerous

  11. Estimates of over-diagnosis of breast cancer due to population-based mammography screening in South Australia after adjustment for lead time effects.

    Science.gov (United States)

    Beckmann, Kerri; Duffy, Stephen W; Lynch, John; Hiller, Janet; Farshid, Gelareh; Roder, David

    2015-09-01

    To estimate over-diagnosis due to population-based mammography screening using a lead time adjustment approach, with lead time measures based on symptomatic cancers only. Women aged 40-84 in 1989-2009 in South Australia eligible for mammography screening. Numbers of observed and expected breast cancer cases were compared, after adjustment for lead time. Lead time effects were modelled using age-specific estimates of lead time (derived from interval cancer rates and predicted background incidence, using maximum likelihood methods) and screening sensitivity, projected background breast cancer incidence rates (in the absence of screening), and proportions screened, by age and calendar year. Lead time estimates were 12, 26, 43 and 53 months, for women aged 40-49, 50-59, 60-69 and 70-79 respectively. Background incidence rates were estimated to have increased by 0.9% and 1.2% per year for invasive and all breast cancer. Over-diagnosis among women aged 40-84 was estimated at 7.9% (0.1-12.0%) for invasive cases and 12.0% (5.7-15.4%) when including ductal carcinoma in-situ (DCIS). We estimated 8% over-diagnosis for invasive breast cancer and 12% inclusive of DCIS cancers due to mammography screening among women aged 40-84. These estimates may overstate the extent of over-diagnosis if the increasing prevalence of breast cancer risk factors has led to higher background incidence than projected. © The Author(s) 2015.

  12. Radiology workstation for mammography: preliminary observations, eyetracker studies, and design

    Science.gov (United States)

    Beard, David V.; Johnston, Richard E.; Pisano, Etta D.; Hemminger, Bradley M.; Pizer, Stephen M.

    1991-07-01

    For the last four years, the UNC FilmPlane project has focused on constructing a radiology workstation facilitating CT interpretations equivalent to those with film and viewbox. Interpretation of multiple CT studies was originally chosen because handling such large numbers of images was considered to be one of the most difficult tasks that could be performed with a workstation. The authors extend the FilmPlane design to address mammography. The high resolution and contrast demands coupled with the number of images often cross- compared make mammography a difficult challenge for the workstation designer. This paper presents the results of preliminary work with workstation interpretation of mammography. Background material is presented to justify why the authors believe electronic mammographic workstations could improve health care delivery. The results of several observation sessions and a preliminary eyetracker study of multiple-study mammography interpretations are described. Finally, tentative conclusions of what a mammographic workstation might look like and how it would meet clinical demand to be effective are presented.

  13. Image quality and dose in mammography in 17 countries in Africa, Asia and Eastern Europe: Results from IAEA projects

    International Nuclear Information System (INIS)

    Ciraj-Bjelac, Olivera; Avramova-Cholakova, Simona; Beganovic, Adnan; Economides, Sotirios; Faj, Dario; Gershan, Vesna; Grupetta, Edward; Kharita, M.H.; Milakovic, Milomir; Milu, Constantin; Muhogora, Wilbroad E.; Muthuvelu, Pirunthavany; Oola, Samuel; Setayeshi, Saeid

    2012-01-01

    Purpose: The objective is to study mammography practice from an optimisation point of view by assessing the impact of simple and immediately implementable corrective actions on image quality. Materials and methods: This prospective multinational study included 54 mammography units in 17 countries. More than 21,000 mammography images were evaluated using a three-level image quality scoring system. Following initial assessment, appropriate corrective actions were implemented and image quality was re-assessed in 24 units. Results: The fraction of images that were considered acceptable without any remark in the first phase (before the implementation of corrective actions) was 70% and 75% for cranio-caudal and medio-lateral oblique projections, respectively. The main causes for poor image quality before corrective actions were related to film processing, damaged or scratched image receptors, or film-screen combinations that are not spectrally matched, inappropriate radiographic techniques and lack of training. Average glandular dose to a standard breast was 1.5 mGy (mean and range 0.59–3.2 mGy). After optimisation the frequency of poor quality images decreased, but the relative contributions of the various causes remained similar. Image quality improvements following appropriate corrective actions were up to 50 percentage points in some facilities. Conclusions: Poor image quality is a major source of unnecessary radiation dose to the breast. An increased awareness of good quality mammograms is of particular importance for countries that are moving towards introduction of population-based screening programmes. The study demonstrated how simple and low-cost measures can be a valuable tool in improving of image quality in mammography

  14. Breast cancer screening with mammography as part of our comprehensive medical check-up

    International Nuclear Information System (INIS)

    Ishii, Kaname; Kaburaki, Tomonori; Iwata, Keiko; Tsuneda, Atsushi; Mori, Kazuhiro; Takeyama, Shigeru; Tsuji, Hiroshi

    2012-01-01

    In the breast cancer screening program adopted by our hospital's Health Care Center as part of a comprehensive medical check-up, mammography (MMG) is performed in addition to a clinical breast examination to provide better screening quality. The clinical breast examination is performed by our surgeons. Two-view MMG is performed for women in their 40's and one-view MMG for the others. If any abnormality is detected in the clinical breast examination, or if MMG reveals abnormalities of category 3 or over, a more thorough diagnostic work-up is recommended. Each year, 1,400 or more women undergo breast cancer screening at the center, with an average recall rate of 12% and an average breast cancer detection rate of 0.14%. The high recall rate indicates the need for improvement of screening accuracy. Although the breast cancer detection rate and positive predictive value are somewhat low, the majority of the detected cases are early-stage breast cancer, thus demonstrating the efficacy of the screening. Herein, we describe the current state of MMG screening in our comprehensive medical check-up, along with a discussion of the screening procedure. However, further efforts are needed to improve screening accuracy. (author)

  15. Indicators of image quality and doses in mammography; Indicadores de calidad de imagen y dosis en mamografia

    Energy Technology Data Exchange (ETDEWEB)

    Gaona, E.; Franco E, J.G. [UAM-X, Calz. del Hueso 1100, 04960 Mexico D.F. (Mexico); Azorin N, J.; Diaz G, J.A.I. [CICATA-IPN, 11500 Mexico D.F. (Mexico); Arreola, M. [Shands Hospital at UF, PO Box 100374, Gainesville FL 32610-0374 (United States)

    2007-07-01

    Full text: The purpose of the study was to determine the values of the image quality indicators and their relationship with the dose in mammography of screen-film that they allowed the detection of a bigger number of objects in the images obtained with the mannequin (phantom) authorized of the ACR/FDA. The study was carried out in four mammography services in a period of 12 months. The indicators of the image quality are the half optic density (DOM), contrast (differences of densities), the number of observed objects in the images and the dose for image. The minimum acceptable values by the ACR/FDA are a half optical density of 1.4, contrast of 0.4 and the one numbers minimum of objects observed in the image of the mannequin of mammography of 10 (4 fibers, 3 groups of calcifications and 3 masses), with a maximum dose by image of 3 mGy. The found results are half optical density of 1.9, contrast of 0.56 and the average number of objects observed in the images of 12, with a dose in the interval of 1.6 mGy to 2.4 mGy. The doses were measured by thermoluminescent dosimetry and ionization chamber. Once carried out the analysis of the tendencies of the indicators of image quality and their distributions is found that for a p < 0.05, the bigger number of objects observed in the images is in the interval from 1.8 to 1.9 of DOM. When comparing both mammography system, the system screen-film has a lower variability in the distribution of objects associated to a DOM. (Author)

  16. Mammography-oncogenecity at low doses

    International Nuclear Information System (INIS)

    Heyes, G J; Mill, A J; Charles, M W

    2009-01-01

    Controversy exists regarding the biological effectiveness of low energy x-rays used for mammography breast screening. Recent radiobiology studies have provided compelling evidence that these low energy x-rays may be 4.42 ± 2.02 times more effective in causing mutational damage than higher energy x-rays. These data include a study involving in vitro irradiation of a human cell line using a mammography x-ray source and a high energy source which matches the spectrum of radiation observed in survivors from the Hiroshima atomic bomb. Current radiation risk estimates rely heavily on data from the atomic bomb survivors, and a direct comparison between the diagnostic energies used in the UK breast screening programme and those used for risk estimates can now be made. Evidence highlighting the increase in relative biological effectiveness (RBE) of mammography x-rays to a range of x-ray energies implies that the risks of radiation-induced breast cancers for mammography x-rays are potentially underestimated by a factor of four. A pooled analysis of three measurements gives a maximal RBE (for malignant transformation of human cells in vitro) of 4.02 ± 0.72 for 29 kVp (peak accelerating voltage) x-rays compared to high energy electrons and higher energy x-rays. For the majority of women in the UK NHS breast screening programme, it is shown that the benefit safely exceeds the risk of possible cancer induction even when this higher biological effectiveness factor is applied. The risk/benefit analysis, however, implies the need for caution for women screened under the age of 50, and particularly for those with a family history (and therefore a likely genetic susceptibility) of breast cancer. In vitro radiobiological data are generally acquired at high doses, and there are different extrapolation mechanisms to the low doses seen clinically. Recent low dose in vitro data have indicated a potential suppressive effect at very low dose rates and doses. Whilst mammography is a low

  17. Evaluation of the quality of the mammography study in the radio-diagnostic service of the National Cancer Institute

    International Nuclear Information System (INIS)

    Rubio Laverde, Alba Lucia; Pineros Petersen, Marion; Betancourt Gil, Claudia

    2003-01-01

    The development of mammography quality control programs at radiology services has had an important progress in the last decades, mainly in developed countries. Although breast cancer is one of the leading causes of cancer mortality and incidence in Colombia, quality control programs for mammography screening are just beginning to be considered. This article describes the results of a baseline evaluation aimed at establishing a quality control program at the Radiology Unit of the National Cancer Institute, in Colombia. The mammography equipment, the film processing, and all main physical parameters were checked and compared to international standards. Quality of the image in 301 mammographic X-ray plates was evaluated. In order to implement a good quality control program, the need for acquiring essential instruments, improving physical facilities and starting a continuous training program is imperative

  18. Patterns and determinants of mammography screening in Lebanese women

    Directory of Open Access Journals (Sweden)

    Nadia Elias

    2017-03-01

    Providing mammography free-of-charge may alleviate some obstacles among women with socio-economic disadvantage. Stressing that good results one year do not make the cancer less likely or repeating the test less important, as well as improving the comfort of mammography testing could ensure test repeating.

  19. Cost-effectiveness and radiological risk associated with mammography screening in Italy

    International Nuclear Information System (INIS)

    Toma, S.; Pino, G.; Brighetti, S.

    1987-01-01

    The available evidence, including biological evidence, supports the notion of a non-linear relationship between dosage and effect, especially when comparing small and average cumulative dosage. There is, however, no specific experimental evidence to demonstrate this, as far as we know. Nor is there any evidence of risk from mammography. Nevertheless, this type of examination in young asymptomatic women should be evaluated in terms of risk/benefit, given the essential role played by latency time in tumour development. The cost-effectiveness of mass screening must be evaluated by simulation of models before the screening itself is begun. The use of mathematical methods in the evaluation of the costs and the benefits is, today, necessary to attain to optimizing decisions, for improving social and medical aspects of a mass screening program. This approach needs tools such as: Markov analysis, Queues theory, Monte Carlo method, Decision theory, Linear programming ect., but its advantages are manifest. It permits to choose the best acts for our needs, satisfying at the same time medical and financial aspects

  20. FDA & digital mammography: why has FDA required full field digital mammography systems to be regulated as potentially dangerous devices for more than 10 years?

    Science.gov (United States)

    Nields, Morgan W

    2010-05-01

    Digital mammography is routinely used in the US to screen asymptomatic women for breast cancer and currently over 50% of US screening centers employ the technology. In spite of FDAs knowledge that digital mammography requires less radiation than film mammography and that its equivalence has been proven in a prospective randomized trial, the agency has failed to allow the technology market access via the 510(k) pre market clearance pathway. As a result of the restrictive Pre Market Approval process, only four suppliers have received FDA approval. The resulting lack of a competitive market has kept costs high, restricted technological innovation, and impeded product improvements as a result of PMA requirements. Meanwhile, at least twelve companies are on the market in the EU and the resulting competitive market has lowered costs and provided increased technological choice. A cultural change with new leadership occurred in the early 90's at FDA. The historical culture at the Center for Devices and Radiological Health of collaboration and education gave way to one characterized by a lack of reliance on outside scientific expertise, tolerance of decision making by unqualified reviewers, and an emphasis on enforcement and punishment. Digital mammography fell victim to this cultural change and as a result major innovations like breast CT and computer aided detection technologies are also withheld from the market. The medical device law, currently under review by the Institute of Medicine, should be amended by the Congress so that new technologies can be appropriately classified in accordance with the risk based assessment classification system detailed in Chapter V of the Federal Food, Drug, and Cosmetic Act. A panel of scientific experts chartered by the NIH or IOM should determine the classification appropriate for new technologies that have no historical regulatory framework. This would be binding on FDA. Unless the law is changed we will likely again experience

  1. Characterization of optically stimulated luminescence for assessment of breast doses in mammography screening

    International Nuclear Information System (INIS)

    Alothmany, N.; Jiman, A.; Molla, N.I.; Natto, H.; Tayeb, M.; Nadwi, F.; Yusuf, M.; Alothmany, D.; Kinsara, A.A.; Saoudi, A.; Mail, N.; Khafaji, M.A.

    2016-01-01

    Landauer optically stimulated luminescence (OSL) technology nanoDot dosimeters (OSLDs) are characterized for use in mammography screening at various tube voltages, mAs values and target/filter combinations. The average glandular dose (AGD) for a 50-mm breast, based on the representative compressed breast thickness of a 45-mm polymethyl methacrylate (PMMA) phantom, is assessed using OSLDs with different beam conditions. Further, the linearity of the OSLD response is measured and angular dependence tests are performed for various tube potentials, mAs and target/filter combinations. The breast-absorbed doses are measured at various depths for a 32-kVp X-ray beam at 100 mAs, with a Mo/Rh target/filter combination. The measured incident air kerma values at different lateral positions exhibit a maximum deviation of 6%, and the average relative response of the OSLDs at the reference point (center) with respect to various lateral positions is found to be 1.001 ± 0.09%. The calculated AGD values are in the 1.3 ± 0.1-3.5 ± 0.2 mGy range, depending on the tube potential, tube loading and target/filter combinations. An exposure setup featuring the auto-exposure control (AEC) mode, 28 kVp, 73.8 mAs, and a Mo/Rh target/filter combination may be preferred for mammography screening for a compressed breast thickness of 45 mm. (authors)

  2. Patterns and determinants of mammography screening in Lebanese women.

    Science.gov (United States)

    Elias, Nadia; Bou-Orm, Ibrahim R; Adib, Salim M

    2017-03-01

    The associations of ever using and/or repeating a mammography test with psychosocial and socio-demographic factors were surveyed in 2014 among Lebanese women ≥ 40. A sample of 2400 women was selected across Lebanon. Variables with significant bivariate associations with various types of behaviors were entered in multivariate analysis. Of the total, 105 women (4·4%) had never heard of mammography as a tool for early breast cancer detection. Among the remaining 2295, 45% had ever used it, of whom 10% had obtained it for the first time within the 12 months preceding the survey. Repeaters were 67% of 926 women who had the time opportunity to do so (median lifetime frequency: 2). Older age, higher socio-economic status (SES) and living within the Greater Beirut (GB) area were significantly associated with ever-use. Within GB, psychosocial factors such as perceived susceptibility and benefits were most strongly associated with ever-use. Outside GB, socio-economic advantage seemed to mostly affect ever-use. Only 4% reported opposition from husbands to their mammography, and husband's support was significant for adherence to mammography guidelines mostly outside GB. Higher education emerged also as a significant socio-demographic determinant for ever-repeating in all regions. Perceived comfort of the previous test strongly affected the likelihood of repeating it. Providing mammography free-of-charge may alleviate some obstacles among women with socio-economic disadvantage. Stressing that good results one year do not make the cancer less likely or repeating the test less important, as well as improving the comfort of mammography testing could ensure test repeating.

  3. Digital Breast Tomosynthesis with Synthesized Two-Dimensional Images versus Full-Field Digital Mammography for Population Screening: Outcomes from the Verona Screening Program.

    Science.gov (United States)

    Caumo, Francesca; Zorzi, Manuel; Brunelli, Silvia; Romanucci, Giovanna; Rella, Rossella; Cugola, Loredana; Bricolo, Paola; Fedato, Chiara; Montemezzi, Stefania; Houssami, Nehmat

    2018-04-01

    Purpose To examine the outcomes of a breast cancer screening program based on digital breast tomosynthesis (DBT) plus synthesized two-dimensional (2D) mammography compared with those after full-field digital mammography (FFDM). Materials and Methods This prospective study included 16 666 asymptomatic women aged 50-69 years who were recruited in April 2015 through March 2016 for DBT plus synthetic 2D screening in the Verona screening program. A comparison cohort of women screened with FFDM (n = 14 423) in the previous year was included. Screening detection measures for the two groups were compared by calculating the proportions associated with each outcome, and the relative rates (RRs) were estimated with multivariate logistic regression. Results Cancer detection rate (CDR) for DBT plus synthetic 2D imaging was 9.30 per 1000 screening examinations versus 5.41 per 1000 screening examinations with FFDM (RR, 1.72; 95% confidence interval [CI]: 1.30, 2.29). CDR was significantly higher in patients screened with DBT plus synthetic 2D imaging than in those screened with FFDM among women classified as having low breast density (RR, 1.53; 95% CI: 1.13, 2.10) or high breast density (RR, 2.86; 95% CI: 1.42, 6.25). The positive predictive value (PPV) for recall was almost doubled with DBT plus synthetic 2D imaging: 23.3% versus 12.9% of recalled patients who were screened with FFDM (RR, 1.81; 95% CI: 1.34, 2.47). The recall rate was similar between groups (RR, 0.95; 95% CI: 0.84, 1.06), whereas the recall rate with invasive assessment was higher for DBT plus synthetic 2D imaging than for FFDM (RR, 1.93; 95% CI: 1.31, 2.03). The mean number of screening studies interpreted per hour was significantly lower for screening examinations performed with DBT plus synthetic 2D imaging (38.5 screens per hour) than with FFDM (60 screens per hour) (P < .001). Conclusion DBT plus synthetic 2D imaging increases CDRs with recall rates comparable to those of FFDM. DBT plus synthetic 2D imaging

  4. Mammography dose in relation to body mass index, race, and menopausal status

    Energy Technology Data Exchange (ETDEWEB)

    Schubauer-Berigan, M.K.; Frey, G.D.; Baron, L.; Hoel, D.G

    2002-07-01

    Mammography dose increases with compressed breast thickness (CBT), but few studies have examined other correlates of dose. The purpose of this study was to evaluate the relation between factors such as race, age, body mass index (BMI), CBT, and menopausal status and mammography screening dose, measured for 509 women in a US population. A multiple linear regression model was developed for dose, based on consideration of these factors as well as examination characteristics. BMI and number of films during examination were positively related to dose. After adjusting for these factors, high CBT also leads to higher dose. Whites receive lower doses than black women, but differences are slight after controlling for the effects of CBT and BMI, which were significantly higher among black women. Pre-menopausal women receive higher doses, after adjusting for all other factors, than post-menopausal women. Jointly, these factors account for approximately 75% to 80% of the variability in dose among this study population. Because rates of overweight are increasing in the US, average doses from mammography may be increasing as well. (author)

  5. Mammography dose in relation to body mass index, race, and menopausal status

    International Nuclear Information System (INIS)

    Schubauer-Berigan, M.K.; Frey, G.D.; Baron, L.; Hoel, D.G.

    2002-01-01

    Mammography dose increases with compressed breast thickness (CBT), but few studies have examined other correlates of dose. The purpose of this study was to evaluate the relation between factors such as race, age, body mass index (BMI), CBT, and menopausal status and mammography screening dose, measured for 509 women in a US population. A multiple linear regression model was developed for dose, based on consideration of these factors as well as examination characteristics. BMI and number of films during examination were positively related to dose. After adjusting for these factors, high CBT also leads to higher dose. Whites receive lower doses than black women, but differences are slight after controlling for the effects of CBT and BMI, which were significantly higher among black women. Pre-menopausal women receive higher doses, after adjusting for all other factors, than post-menopausal women. Jointly, these factors account for approximately 75% to 80% of the variability in dose among this study population. Because rates of overweight are increasing in the US, average doses from mammography may be increasing as well. (author)

  6. Digital mammography and their developments

    International Nuclear Information System (INIS)

    Wienbeck, Susanne

    2015-01-01

    At the present time digital mammography is a satisfactory breast diagnostic imaging in clinical as well as screening mammography in defined age groups. Nevertheless it shows beside the application of ionizing radiation in women with dense breasts limitations in the detection of non calcification breast cancers. Tomosynthesis, digital contrast-enhanced mammography and breast-CT with or without contrast media lead to better results. Especially the application of contrast media for the visualisation of the tumor angiogenesis is invariably superior to all other non-contrast imaging modalities. However, the excellent results of breast MRI will be probably accessible with none of the new procedures.

  7. Impact of full field digital mammography on the classification and mammographic characteristics of interval breast cancers

    Energy Technology Data Exchange (ETDEWEB)

    Knox, Mark, E-mail: marktknox@gmail.com; O’Brien, Angela, E-mail: angelaobrien@doctors.org.uk; Szabó, Endre, E-mail: endrebacsi@freemail.hu; Smith, Clare S., E-mail: csmith@mater.ie; Fenlon, Helen M., E-mail: helen.fenlon@cancerscreening.ie; McNicholas, Michelle M., E-mail: michelle.mcnicholas@cancerscreening.ie; Flanagan, Fidelma L., E-mail: fidelma.flanagan@cancerscreening.ie

    2015-06-15

    Highlights: • Digital mammography has changed the presentation of interval breast cancer. • Less interval breast cancers are associated with microcalcifications following FFDM. • Interval breast cancer audit remains a key feature of any breast screening program. - Abstract: Objective: Full field digital mammography (FFDM) is increasingly replacing screen film mammography (SFM) in breast screening programs. Interval breast cancers are an issue in all screening programs and the purpose of our study is to assess the impact of FFDM on the classification of interval breast cancers at independent blind review and to compare the mammographic features of interval cancers at FFDM and SFM. Materials and methods: This study included 138 cases of interval breast cancer, 76 following an FFDM screening examination and 62 following screening with SFM. The prior screening mammogram was assessed by each of five consultant breast radiologists who were blinded to the site of subsequent cancer. Subsequent review of the diagnostic mammogram was performed and cases were classified as missed, minimal signs, occult or true interval. Mammographic features of the interval cancer at diagnosis and any abnormality identified on the prior screening mammogram were recorded. Results: The percentages of cancers classified as missed at FFDM and SFM did not differ significantly, 10.5% (8 of 76) at FFDM and 8.1% (5 of 62) at SFM (p = .77). There were significantly less interval cancers presenting as microcalcifications (alone or in association with another abnormality) following screening with FFDM, 16% (12 of 76) than following a SFM examination, 32% (20 of 62) (p = .02). Conclusion: Interval breast cancers continue to pose a problem at FFDM. The switch to FFDM has changed the mammographic presentation of interval breast cancer, with less interval cancers presenting in association with microcalcifications.

  8. Impact of full field digital mammography on the classification and mammographic characteristics of interval breast cancers

    International Nuclear Information System (INIS)

    Knox, Mark; O’Brien, Angela; Szabó, Endre; Smith, Clare S.; Fenlon, Helen M.; McNicholas, Michelle M.; Flanagan, Fidelma L.

    2015-01-01

    Highlights: • Digital mammography has changed the presentation of interval breast cancer. • Less interval breast cancers are associated with microcalcifications following FFDM. • Interval breast cancer audit remains a key feature of any breast screening program. - Abstract: Objective: Full field digital mammography (FFDM) is increasingly replacing screen film mammography (SFM) in breast screening programs. Interval breast cancers are an issue in all screening programs and the purpose of our study is to assess the impact of FFDM on the classification of interval breast cancers at independent blind review and to compare the mammographic features of interval cancers at FFDM and SFM. Materials and methods: This study included 138 cases of interval breast cancer, 76 following an FFDM screening examination and 62 following screening with SFM. The prior screening mammogram was assessed by each of five consultant breast radiologists who were blinded to the site of subsequent cancer. Subsequent review of the diagnostic mammogram was performed and cases were classified as missed, minimal signs, occult or true interval. Mammographic features of the interval cancer at diagnosis and any abnormality identified on the prior screening mammogram were recorded. Results: The percentages of cancers classified as missed at FFDM and SFM did not differ significantly, 10.5% (8 of 76) at FFDM and 8.1% (5 of 62) at SFM (p = .77). There were significantly less interval cancers presenting as microcalcifications (alone or in association with another abnormality) following screening with FFDM, 16% (12 of 76) than following a SFM examination, 32% (20 of 62) (p = .02). Conclusion: Interval breast cancers continue to pose a problem at FFDM. The switch to FFDM has changed the mammographic presentation of interval breast cancer, with less interval cancers presenting in association with microcalcifications

  9. The results of a quality-control programme in mammography

    International Nuclear Information System (INIS)

    Ramsdale, M.L.; Hiles, P.A.

    1989-01-01

    A quality-control programme at a breast screening clinic is described. Daily checks include film sensitometry for X-ray processor control and radiography of a lucite phantom to monitor the consistency of the X-ray machine automatic exposure control. Weekly checks include additional measurements on the performance of the automatic exposure control for different breast thickness and an overall assessment of image quality using a prototype mammography test phantom. The test phantom measures low-contrast sensitivity, high-control resolution and small-detail visibility. The results of the quality-control programme are presented with particular attention paid to tolerances and limiting values. (author)

  10. Prospective study aiming to compare 2D mammography and tomosynthesis + synthesized mammography in terms of cancer detection and recall. From double reading of 2D mammography to single reading of tomosynthesis.

    Science.gov (United States)

    Romero Martín, Sara; Raya Povedano, Jose Luis; Cara García, María; Santos Romero, Ana Luz; Pedrosa Garriguet, Margarita; Álvarez Benito, Marina

    2018-06-01

    To evaluate tomosynthesis compared with 2D-mammography in cancer detection and recalls in a screening-programme, and assess performing synthesized instead of 2D, and compare double reading of 2D with single reading of tomosynthesis. Women (age 50-69 years) participating in the screening-programme were included. 2D-mammography and tomosynthesis were performed. There were four reading models: 2D-mammography (first); 2D-mammography (second); tomosynthesis + synthesized (third); tomosynthesis + synthesized + 2D (fourth reading). Paired double reading of 2D (first+second) and tomosynthesis (third+fourth) were analysed. In 16,067 participants, there were 98 cancers and 1,196 recalls. Comparing double reading of 2D with single reading of tomosynthesis, there was an increase of 12.6 % in cancer detection with the third reading (p= 0.043) and 6.9 % with the fourth reading (p=0.210), and a decrease in recalls of 40.5 % (ptomosynthesis. Single reading of tomosynthesis plus synthesized increased cancer detection and decreased recalls compared with double reading 2D. 2D did not improve results when added to tomosynthesis. • Tomosynthesis increases cancer detection and decreases recall rates versus 2D mammography. • Synthesized-mammography avoids performing 2D, showing higher cancer detection. • Single reading of tomosynthesis + synthesized is feasible as a new practice.

  11. Preparing women for breast screening mammography: A feasibility study to determine the potential value of an on-line social network and information hub

    International Nuclear Information System (INIS)

    Robinson, L.; Griffiths, M.; Wray, J.; Ure, C.; Shires, G.; Stein-Hodgins, J.R.; Hill, C.; Hilton, B.

    2015-01-01

    This feasibility study explored the attitudes of women towards social media for support about breast screening mammography. It sought their ideas about what a dedicated breast screening hub or Digital Support Network (DSN) might comprise; how they would network with other women on the DSN; what format information might take; and whether a health professional should be available on the DSN. Data comprised 94 survey questionnaires and two focus groups; one comprised women in the breast screening population age group, the other was a younger group. A socio-ecological framework was used to identify key influencers and potential barriers for the implementation of a mammography DSN. The study identified issues related to three intersecting concepts which influenced women's behaviour: on-line conversations about health in general; on-line conversations about breast screening mammography and the culture of privacy which makes conversing about intimate health (either face to face or on-line) difficult. Also, the transient nature of the mammography episode (three yearly), could mean an on-line breast screening digital network is challenging to sustain. super-users’ may be needed to continue on-line conversations. The health professional was also seen as essential for moderating potential misinformation shared by women although the participants were also insistent that ‘truth’ be shared. - Highlights: • Ensure factual information is provided that is in textual format with images and video. • Provide option to network in private. • Develop health practitioners who can provide a balanced perspective in facilitating the sharing of true experiences. • Work with employers to implement organisational changes. • Target certain groups in more direct ways (i.e. those with lower self-efficacy in terms of on-line skills).

  12. Mammography in breast cancer screening. A radiographic analysis of the carcinomas found at Utrecht, Nijmegen and Kopparberg county

    International Nuclear Information System (INIS)

    Muller, J.W.T.

    1985-01-01

    Population-based screening for carcinoma of the breast by mammography has yielded an abundance of data, not all of which have been processed yet, the mammographic (radiographic) data in particular. The present study concerns an analysis of the mammographic signs in the histologically proven carcinomas (invasive and intraductal) detected by these three screening programs. The radiographic signs of the screened carcinomas were compared with those of the clinical carcinomas diagnosed in the Utrecht University Hospital (to be called AZU carcinomas). These AZU carcinomas were taken as reference material, and were therefore analysed in the same way as the screening material. (Auth.)

  13. Sensitivity of screen-film systems

    International Nuclear Information System (INIS)

    Sandborg, M.; Nilsson, Goergen; Holje, G.

    1992-01-01

    This report, which has been funded by SSI, presents sensitivity data on the 'second generation' of modern intensifying screens, commercially available at the onset of the investigation. The sensitivity of the screen-film systems was evaluated with 80 kV tube potential and a total filtration of 3.0 mm Al. 20 mm aluminum was used for simulating human tissue, since it gives the same HVL x , as does 25 cm water. Kerma in air, needed to produce a net film density of 1.00 was determined and its inverse, expressed in mGy -1 , was taken as an indicator of the sensitivity; here called the sensitivity class of a screen-film system

  14. Breast cancer incidence and mortality in the Nordic capitals, 1970-1998. Trends related to mammography screening programmes

    DEFF Research Database (Denmark)

    Törnberg, Sven; Kemetli, Levent; Lynge, Elsebeth

    2006-01-01

    The aim of the present study was to relate the time trends in breast cancer incidence and mortality to the introduction of mammography screening in the Nordic capitals. Helsinki offered screening to women aged 50-59 starting in 1986. The other three capitals offered screening to women aged 50......-69 starting in 1989 in Stockholm, 1991 in Copenhagen, and 1996 in Oslo. Prevalence peaks in breast cancer incidence depended on the age groups covered by the screening, the length of the implementation of screening, and the extent of background opportunistic screening. No mortality reduction following...... the introduction of screening was visible after seven to 12 years of screening in any of the three capitals where significant effects of the screening on the breast cancer mortality had already been demonstrated by using other analytical methods for the evaluation. No visible effect on mortality reduction...

  15. Screening mammography beliefs and recommendations: a web-based survey of primary care physicians

    Directory of Open Access Journals (Sweden)

    Yasmeen Shagufta

    2012-02-01

    Full Text Available Abstract Background The appropriateness and cost-effectiveness of screening mammography (SM for women younger than 50 and older than 74 years is debated in the clinical research community, among health care providers, and by the American public. This study explored primary care physicians' (PCPs perceptions of the influence of clinical practice guidelines for SM; the recommendations for SM in response to hypothetical case scenarios; and the factors associated with perceived SM effectiveness and recommendations in the US from June to December 2009 before the United States Preventive Services Task Force (USPSTF recently revised guidelines. Methods A nationally representative sample of 11,922 PCPs was surveyed using a web-based questionnaire. The response rate was 5.7% (684; (41% 271 family physicians (FP, (36% 232 general internal medicine physicians (IM, (23% 150 obstetrician-gynaecologists (OBG, and (0.2% 31 others. Cross-sectional analysis examined PCPs perceived effectiveness of SM, and recommendation for SM in response to hypothetical case scenarios. PCPs responses were measured using 4-5 point adjectival scales. Differences in perceived effectiveness and recommendations for SM were examined after adjusting for PCPs specialty, race/ethnicity, and the US region. Results Compared to IM and FP, OBG considered SM more effective in reducing breast cancer mortality among women aged 40-49 years (p = 0.003. Physicians consistently recommended mammography to women aged 50-69 years with no differences by specialty (p = 0.11. However, 94% of OBG "always recommended" SM to younger and 86% of older women compared to 81% and 67% for IM and 84% and 59% for FP respectively (p = p = Conclusions A majority of physicians, especially OBG, favour aggressive breast cancer screening for women from 40 through 79 years of age, including women with short life expectancy. Policy interventions should focus on educating providers to provide tailored recommendations for

  16. Position paper on screening for breast cancer by the European Society of Breast Imaging (EUSOBI) and 30 national breast radiology bodies from Austria, Belgium, Bosnia and Herzegovina, Bulgaria, Croatia, Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Israel, Lithuania, Moldova, The Netherlands, Norway, Poland, Portugal, Romania, Serbia, Slovakia, Spain, Sweden, Switzerland and Turkey.

    Science.gov (United States)

    Sardanelli, Francesco; Aase, Hildegunn S; Álvarez, Marina; Azavedo, Edward; Baarslag, Henk J; Balleyguier, Corinne; Baltzer, Pascal A; Beslagic, Vanesa; Bick, Ulrich; Bogdanovic-Stojanovic, Dragana; Briediene, Ruta; Brkljacic, Boris; Camps Herrero, Julia; Colin, Catherine; Cornford, Eleanor; Danes, Jan; de Geer, Gérard; Esen, Gul; Evans, Andrew; Fuchsjaeger, Michael H; Gilbert, Fiona J; Graf, Oswald; Hargaden, Gormlaith; Helbich, Thomas H; Heywang-Köbrunner, Sylvia H; Ivanov, Valentin; Jónsson, Ásbjörn; Kuhl, Christiane K; Lisencu, Eugenia C; Luczynska, Elzbieta; Mann, Ritse M; Marques, Jose C; Martincich, Laura; Mortier, Margarete; Müller-Schimpfle, Markus; Ormandi, Katalin; Panizza, Pietro; Pediconi, Federica; Pijnappel, Ruud M; Pinker, Katja; Rissanen, Tarja; Rotaru, Natalia; Saguatti, Gianni; Sella, Tamar; Slobodníková, Jana; Talk, Maret; Taourel, Patrice; Trimboli, Rubina M; Vejborg, Ilse; Vourtsis, Athina; Forrai, Gabor

    2017-07-01

    EUSOBI and 30 national breast radiology bodies support mammography for population-based screening, demonstrated to reduce breast cancer (BC) mortality and treatment impact. According to the International Agency for Research on Cancer, the reduction in mortality is 40 % for women aged 50-69 years taking up the invitation while the probability of false-positive needle biopsy is screening. Mortality reduction was also observed for the age groups 40-49 years and 70-74 years, although with "limited evidence". Thus, we firstly recommend biennial screening mammography for average-risk women aged 50-69 years; extension up to 73 or 75 years, biennially, is a second priority, from 40-45 to 49 years, annually, a third priority. Screening with thermography or other optical tools as alternatives to mammography is discouraged. Preference should be given to population screening programmes on a territorial basis, with double reading. Adoption of digital mammography (not film-screen or phosphor-plate computer radiography) is a priority, which also improves sensitivity in dense breasts. Radiologists qualified as screening readers should be involved in programmes. Digital breast tomosynthesis is also set to become "routine mammography" in the screening setting in the next future. Dedicated pathways for high-risk women offering breast MRI according to national or international guidelines and recommendations are encouraged. • EUSOBI and 30 national breast radiology bodies support screening mammography. • A first priority is double-reading biennial mammography for women aged 50-69 years. • Extension to 73-75 and from 40-45 to 49 years is also encouraged. • Digital mammography (not film-screen or computer radiography) should be used. • DBT is set to become "routine mammography" in the screening setting in the next future.

  17. A multiparametric automatic method to monitor long-term reproducibility in digital mammography: results from a regional screening programme.

    Science.gov (United States)

    Gennaro, G; Ballaminut, A; Contento, G

    2017-09-01

    This study aims to illustrate a multiparametric automatic method for monitoring long-term reproducibility of digital mammography systems, and its application on a large scale. Twenty-five digital mammography systems employed within a regional screening programme were controlled weekly using the same type of phantom, whose images were analysed by an automatic software tool. To assess system reproducibility levels, 15 image quality indices (IQIs) were extracted and compared with the corresponding indices previously determined by a baseline procedure. The coefficients of variation (COVs) of the IQIs were used to assess the overall variability. A total of 2553 phantom images were collected from the 25 digital mammography systems from March 2013 to December 2014. Most of the systems showed excellent image quality reproducibility over the surveillance interval, with mean variability below 5%. Variability of each IQI was 5%, with the exception of one index associated with the smallest phantom objects (0.25 mm), which was below 10%. The method applied for reproducibility tests-multi-detail phantoms, cloud automatic software tool to measure multiple image quality indices and statistical process control-was proven to be effective and applicable on a large scale and to any type of digital mammography system. • Reproducibility of mammography image quality should be monitored by appropriate quality controls. • Use of automatic software tools allows image quality evaluation by multiple indices. • System reproducibility can be assessed comparing current index value with baseline data. • Overall system reproducibility of modern digital mammography systems is excellent. • The method proposed and applied is cost-effective and easily scalable.

  18. Understanding women's mammography intentions: a theory-based investigation.

    Science.gov (United States)

    Naito, Mikako; O'Callaghan, Frances V; Morrissey, Shirley

    2009-01-01

    The present study compared the utility of two models (the Theory of Planned Behavior and Protection Motivation Theory) in identifying factors associated with intentions to undertake screening mammography, before and after an intervention. The comparison was made between the unique components of the two models. The effect of including implementation intentions was also investigated. Two hundred and fifty-one women aged 37 to 69 years completed questionnaires at baseline and following the delivery of a standard (control) or a protection motivation theory-based informational intervention. Hierarchical multiple regressions indicated that theory of planned behavior variables were associated with mammography intentions. Results also showed that inclusion of implementation intention in the model significantly increased the association with mammography intentions. The findings suggest that future interventions aiming to increase screening mammography participation should focus on the theory of planned behavior variables and that implementation intention should also be targeted.

  19. An evaluation of four rare-earth film-screen combinations

    International Nuclear Information System (INIS)

    Nettle, J.R.L.; Ritchings, R.T.

    1980-01-01

    Objective and subjective assessments were made on four film-screen combinations at 140 kV for use on an EMI body scanner. The combinations used were: 3M XD film + Trimax Alpha 8 screens; Agfa Gevaert RP film + MR600 screens; Kodak Ortho G film + Lanex regular screens and Ilford type S film + rare earth rapid R screens. The objective assessment is based on the optical density of the image of a test object on a radiograph. Receiver operating characteristic techniques are used in the subjective assessment. The best results in each assessment were obtained using the Kodak Ortho G film + Lanex regular screens. (author)

  20. Comparing the diagnostic efficacy of full field digital mammography with digital breast tomosynthesis using BIRADS score in a tertiary cancer care hospital.

    Science.gov (United States)

    Singla, Divya; Chaturvedi, Arvind K; Aggarwal, Abhinav; Rao, S A; Hazarika, Dibyamohan; Mahawar, Vivek

    2018-01-01

    Breast cancer is one of the leading cancers in females worldwide, and its incidence has been rising at an exponential pace in the last 10 years even in India. Mammography has been the mainstay for detection of breast cancer over decades and has gradually advanced from screen film to full-field digital mammography. Recently, tomosynthesis has evolved as an advanced imaging investigation for early diagnosis of breast lesions in both diagnostic and screening settings. To compare and evaluate the impact of digital breast tomosynthesis (DBT) compared to full-field digital mammography (FFDM) in the interpretation of BIRADS score in both diagnostic and screening settings. A 1-year prospective longitudinal study was conducted in the Department of Radio-diagnosis in our institute using Hologic Selenia Dimensions for mammography as well as tomosynthesis. One hundred women known or suspected (opportunistic screening) for breast cancer were evaluated either with FFDM alone or both FFDM and DBT. Sensitivity, specificity, positive predictive value, negative predictive value, and P value were used to assess the various diagnostic criteria in our study. Addition of DBT to FFDM results in a statistically significant increase in the sensitivity, specificity, and positive predictive value, and a statistically significant decrease in the false positive rates. Similar results were noted in both diagnostic and screening cases. It was observed that, in most cases, i.e. a total of 47, DBT did not change the BIRADS scoring; however, its addition increased the diagnostic confidence. BIRADS was upgraded and downgraded in 14 and 31 cases, respectively, with the addition of DBT to FFDM. New lesions were seen with addition of DBT to FFDM in 8 cases. Addition of DBT to FFDM results in increase in sensitivity, specificity, positive predictive value, and a statistically significant decrease in false positive rates in both diagnostic and screening cases. As addition of tomosynthesis results in a

  1. Comparing the diagnostic efficacy of full field digital mammography with digital breast tomosynthesis using BIRADS score in a tertiary cancer care hospital

    Directory of Open Access Journals (Sweden)

    Divya Singla

    2018-01-01

    Full Text Available Introduction: Breast cancer is one of the leading cancers in females worldwide, and its incidence has been rising at an exponential pace in the last 10 years even in India. Mammography has been the mainstay for detection of breast cancer over decades and has gradually advanced from screen film to full-field digital mammography. Recently, tomosynthesis has evolved as an advanced imaging investigation for early diagnosis of breast lesions in both diagnostic and screening settings. Aim of Study: To compare and evaluate the impact of digital breast tomosynthesis (DBT compared to full-field digital mammography (FFDM in the interpretation of BIRADS score in both diagnostic and screening settings. Settings and Design: A 1-year prospective longitudinal study was conducted in the Department of Radio-diagnosis in our institute using Hologic Selenia Dimensions for mammography as well as tomosynthesis. Materials and Methods: One hundred women known or suspected (opportunistic screening for breast cancer were evaluated either with FFDM alone or both FFDM and DBT. Sensitivity, specificity, positive predictive value, negative predictive value, and P value were used to assess the various diagnostic criteria in our study. Results: Addition of DBT to FFDM results in a statistically significant increase in the sensitivity, specificity, and positive predictive value, and a statistically significant decrease in the false positive rates. Similar results were noted in both diagnostic and screening cases. It was observed that, in most cases, i.e. a total of 47, DBT did not change the BIRADS scoring; however, its addition increased the diagnostic confidence. BIRADS was upgraded and downgraded in 14 and 31 cases, respectively, with the addition of DBT to FFDM. New lesions were seen with addition of DBT to FFDM in 8 cases. Conclusion: Addition of DBT to FFDM results in increase in sensitivity, specificity, positive predictive value, and a statistically significant

  2. Trends in mammography utilization for breast cancer screening in a Middle-Eastern country: Lebanon 2005-2013.

    Science.gov (United States)

    Haddad, Fady G; Kourie, Hampig Raphael; Adib, Salim M

    2015-12-01

    In Lebanon, annual national breast awareness campaigns were started in 2002 during the international breast month of October to promote the utilization of mammography for women aged ≥ 40. The impact of the campaigns has been assessed periodically since 2003. Results of 2003-2005 campaigns have been published previously. To measure the prevalence of two behavioral outcomes of interest: ever-use of mammography, and repeat mammography in the previous 12 months among ever-users. The prevalence was described by region and age group. The aim was to document the effectiveness of the program towards reaching a nationally defined goal of 80% screening coverage. The survey's sampling frame was developed incrementally, and since 2005 it has included women aged ≥ 40 from all areas of Lebanon. The sample size has also increased incrementally from 1200 in 2005 to 2400 in 2013. Results have been tabulated biannually and presented as historical trends with regional and demographic variations covering a 9-year period. In all six consecutive surveys presented here, the mean age of participating women was about 50 years. Year-by-year increases in utilization indicators were detected, with consistent differences in favor of the more urban areas in and around the capital city Beirut and its suburbs (Greater Beirut or GB). By 2013, ever-utilization had reached 43% (41-45) and recent mammography 20% (18-22) nationwide. Utilization was significantly more important in the age group 50-59 compared with the age group 40-49 or ≥ 60. While recent rates have increased nationwide, they have reached a plateau of about 25% in GB and are tending to the same level in other areas. While initial progress was slow, it has been accelerating in the last 4-5 years, indicating that the message is being accepted by a larger audience of targeted women at each iteration. However, concern remains that women between 40 and 50 and those >60 are not responding as well as desired to the screening message

  3. Beyond the mammography debate: a moderate perspective.

    Science.gov (United States)

    Kaniklidis, C

    2015-06-01

    After some decades of contention, one can almost despair and conclude that (paraphrasing) "the mammography debate you will have with you always." Against that sentiment, in this review I argue, after reflecting on some of the major themes of this long-standing debate, that we must begin to move beyond the narrow borders of claim and counterclaim to seek consensus on what the balance of methodologically sound and critically appraised evidence demonstrates, and also to find overlooked underlying convergences; after acknowledging the reality of some residual and non-trivial harms from mammography, to promote effective strategies for harm mitigation; and to encourage deployment of new screening modalities that will render many of the issues and concerns in the debate obsolete. To these ends, I provide a sketch of what this looking forward and beyond the current debate might look like, leveraging advantages from abbreviated breast magnetic resonance imaging technologies (such as the ultrafast and twist protocols) and from digital breast tomosynthesis-also known as three-dimensional mammography. I also locate the debate within the broader context of mammography in the real world as it plays out not for the disputants, but for the stakeholders themselves: the screening-eligible patients and the physicians in the front lines who are charged with enabling both the acts of screening and the facts of screening at their maximally objective and patient-accessible levels to facilitate informed decisions.

  4. Contrast-enhanced spectral mammography in recalls from the Dutch breast cancer screening program: validation of results in a large multireader, multicase study.

    Science.gov (United States)

    Lalji, U C; Houben, I P L; Prevos, R; Gommers, S; van Goethem, M; Vanwetswinkel, S; Pijnappel, R; Steeman, R; Frotscher, C; Mok, W; Nelemans, P; Smidt, M L; Beets-Tan, R G; Wildberger, J E; Lobbes, M B I

    2016-12-01

    Contrast-enhanced spectral mammography (CESM) is a promising problem-solving tool in women referred from a breast cancer screening program. We aimed to study the validity of preliminary results of CESM using a larger panel of radiologists with different levels of CESM experience. All women referred from the Dutch breast cancer screening program were eligible for CESM. 199 consecutive cases were viewed by ten radiologists. Four had extensive CESM experience, three had no CESM experience but were experienced breast radiologists, and three were residents. All readers provided a BI-RADS score for the low-energy CESM images first, after which the score could be adjusted when viewing the entire CESM exam. BI-RADS 1-3 were considered benign and BI-RADS 4-5 malignant. With this cutoff, we calculated sensitivity, specificity and area under the ROC curve. CESM increased diagnostic accuracy in all readers. The performance for all readers using CESM was: sensitivity 96.9 % (+3.9 %), specificity 69.7 % (+33.8 %) and area under the ROC curve 0.833 (+0.188). CESM is superior to conventional mammography, with excellent problem-solving capabilities in women referred from the breast cancer screening program. Previous results were confirmed even in a larger panel of readers with varying CESM experience. • CESM is consistently superior to conventional mammography • CESM increases diagnostic accuracy regardless of a reader's experience • CESM is an excellent problem-solving tool in recalls from screening programs.

  5. Diagnostic accuracy and recall rates for digital mammography and digital mammography combined with one-view and two-view tomosynthesis: results of an enriched reader study.

    Science.gov (United States)

    Rafferty, Elizabeth A; Park, Jeong Mi; Philpotts, Liane E; Poplack, Steven P; Sumkin, Jules H; Halpern, Elkan F; Niklason, Loren T

    2014-02-01

    The purpose of this study was to compare two methods of combining tomosynthesis with digital mammography by assessing diagnostic accuracy and recall rates for digital mammography alone and digital mammography combined with one-view tomosynthesis and two-view tomosynthesis. Three hundred ten cases including biopsy-proven malignancies (51), biopsy-proven benign findings (47), recalled screening cases (138), and negative screening cases (74) were reviewed by 15 radiologists sequentially using digital mammography, adding one-view tomosynthesis, and then two-view tomosynthesis. Cases were assessed for recall and assigned a BI-RADS score and probability of malignancy for each imaging method. Diagnostic accuracy was assessed using receiver operating characteristic (ROC) analysis. Screening recall rates were compared using pooled logistical regression analysis. A p value of tomosynthesis, and DM plus two-view tomosynthesis was 0.828, 0.864, and 0.895, respectively. Both one-view and two-view tomosynthesis plus DM were significantly better than DM alone (Δ AUCs 0.036 [p = 0.009] and 0.068 [p tomosynthesis, and DM plus two-view tomosynthesis were 44.2%, 27.2%, and 24.0%, respectively. Combined with DM, one-view and two-view tomosynthesis both showed significantly lower noncancer recall rates than digital mammography alone (p tomosynthesis showed a significantly lower recall rate than digital mammography with one-view tomosynthesis (p tomosynthesis compared with digital mammography alone. Compared with digital mammography, diagnostic sensitivity for invasive cancers increased with the addition of both one-view (Δ12.0%, p tomosynthesis. The addition of one-view tomosynthesis to conventional digital mammography improved diagnostic accuracy and reduced the recall rate; however, the addition of two-view tomosynthesis provided twice the performance gain in diagnostic accuracy while further reducing the recall rate.

  6. Latent fingerprints on different type of screen protective films

    Directory of Open Access Journals (Sweden)

    Yuttana Sudjaroen

    2016-07-01

    Full Text Available The purpose of this research was to study the quality of latent fingerprint on different types of screen protective films including screen protector, matte screen protector, anti-fingerprint clear screen protector and anti-fingerprint matte screen protector by using black powder method in developing latent fingerprints. The fingerprints were performed by 10 volunteers whose fingers (right index, right thumb, left index and left thumb were stubbing at different types of screen protective films and subsequently latent fingerprints were developed by brushing with black powder. Automated Fingerprint Identification System (AFIS counted the numbers of minutiae points from 320 latent fingerprints. Anti-fingerprint matte screen protective film produced the best quality of latent fingerprint with an average minutiae point 72.65, followed by matte screen protective film, clear screen protective film and anti-fingerprint clear screen protective film with an average minutiae point of 155.2, 135.0 and 72.65 respectively. The quality of latent fingerprints developed between a clear and a matte surface of screen protective films showed a significant difference (sig>0.05, whereas the coat and the non-coat with anti-fingerprint chemical revealed a non-significant difference (sig<0.05 in their number of minutiae points.

  7. Mammography and breast sonography in transsexual women

    International Nuclear Information System (INIS)

    Weyers, S.; Villeirs, G.; Vanherreweghe, E.; Verstraelen, H.; Monstrey, S.; Van den Broecke, R.; Gerris, J.

    2010-01-01

    Data on the necessity of performing screening mammographies in transsexual women are lacking. The main objective of this study was to assess the possibility to perform mammography and breast sonography in transsexual women. Fifty Dutch-speaking transsexual women were interviewed about the following: attitude towards mammography and breast sonography, importance attributed to and satisfaction with breast appearance, opinion about the necessity of breast check-up, expectations regarding discomfort during the exams and knowledge about the breast surgery. A fasting blood sample, clinical breast exam, mammography and breast sonography were performed. At mammography the following parameters were noted: density, technical quality, location of the prostheses, presence of any abnormalities and painfulness. At sonography the following parameters were recorded: density, presence of cysts, visualisation of retro-areolar ducts or any abnormalities. Twenty-three percent of patients are not aware of the type of breast implants and 79% do not know their position to the pectoral muscles. Patient satisfaction with the appearance of their breasts was rather high (7.94 on a scale of 0-10). Mean expected and experienced pain from mammography was low (4.37 and 2.00 respectively). There was no statistically significant difference in expected pain between those who already had mammography and those who did not. There was a significant positive correlation between the expected and the experienced pain. Mammography and breast sonography were technically feasible and no gross anomalies were detected. Since both exams were judged as nearly painless, 98% of transsexual women intended to come back if they would be invited. Since breast cancer risk in transsexual women is largely unknown and breast exams are very well accepted, breast screening habits in this population should not differ from those of biological women.

  8. Mammography and breast sonography in transsexual women

    Energy Technology Data Exchange (ETDEWEB)

    Weyers, S., E-mail: steven.weyers@ugent.b [Department of Gynecology, Ghent University Hospital, De Pintelaan 185, B-9000 Ghent (Belgium); Villeirs, G.; Vanherreweghe, E. [Department of Radiology, Ghent University Hospital, Ghent (Belgium); Verstraelen, H. [Department of Gynecology, Ghent University Hospital, De Pintelaan 185, B-9000 Ghent (Belgium); Monstrey, S. [Department of Plastic Surgery, Ghent University Hospital, Ghent (Belgium); Van den Broecke, R.; Gerris, J. [Department of Gynecology, Ghent University Hospital, De Pintelaan 185, B-9000 Ghent (Belgium)

    2010-06-15

    Data on the necessity of performing screening mammographies in transsexual women are lacking. The main objective of this study was to assess the possibility to perform mammography and breast sonography in transsexual women. Fifty Dutch-speaking transsexual women were interviewed about the following: attitude towards mammography and breast sonography, importance attributed to and satisfaction with breast appearance, opinion about the necessity of breast check-up, expectations regarding discomfort during the exams and knowledge about the breast surgery. A fasting blood sample, clinical breast exam, mammography and breast sonography were performed. At mammography the following parameters were noted: density, technical quality, location of the prostheses, presence of any abnormalities and painfulness. At sonography the following parameters were recorded: density, presence of cysts, visualisation of retro-areolar ducts or any abnormalities. Twenty-three percent of patients are not aware of the type of breast implants and 79% do not know their position to the pectoral muscles. Patient satisfaction with the appearance of their breasts was rather high (7.94 on a scale of 0-10). Mean expected and experienced pain from mammography was low (4.37 and 2.00 respectively). There was no statistically significant difference in expected pain between those who already had mammography and those who did not. There was a significant positive correlation between the expected and the experienced pain. Mammography and breast sonography were technically feasible and no gross anomalies were detected. Since both exams were judged as nearly painless, 98% of transsexual women intended to come back if they would be invited. Since breast cancer risk in transsexual women is largely unknown and breast exams are very well accepted, breast screening habits in this population should not differ from those of biological women.

  9. High intensification screen-film systems in thorax radiography: a clinical comparison

    International Nuclear Information System (INIS)

    Schaefer, C.B.; Sokiranski, R.; Claussen, C.D.

    1995-01-01

    Objective: The quality of chest images was evaluated for a conventional screen-film system, a new asymmetric screen-film system, and a new uv screen-film system. Materials and Methods: 138 Chest radiographs (69 p.a., 69 lateral) obtained with three different high intensification screen-film combinations were compared. Film density and film contrast were measured. Three readers graded the image quality according to 16 criteria. Results: The asymmetric film-screen combination Insight HC showed the lowest film contrast, the best exposure range, and a elevated film density in the mediastinal area. The asymmetric screen-film system was ranked by all three observers as being substantially better in image quality. Conclusion: Compared to conventional screen-film systems, the new screen-film systems can improve the image quality of chest radiographs. Therefore, the new high intensification screen-film combinations can be used as a low cost alternative to the Amber technique and digital radiography. (orig.) [de

  10. Assessment of the willingness of Australian radiographers in mammography to accept new responsibilities in role extension: Part two – qualitative analysis

    International Nuclear Information System (INIS)

    Moran, S.; Taylor, J.K.; Warren-Forward, H.

    2013-01-01

    Advanced practice in screening mammography has become widespread in the United Kingdom over the last 20 years, and Australian radiographers working in BreastScreen programs have shown interest in similar developments. Radiographers working in BreastScreen Australia were surveyed in order to capture their thoughts and perceptions on role extension. Questionnaires were circulated to radiographers working in BreastScreen Australia programs. Thematic analysis was used to analyze the open response questions to explore the advantages and disadvantages identified by the participants with respect to role expansion in screening mammography as well as any changes to their duties over the last decade. There were 253 responses to the survey and of those responses, 70% of radiographers shared their thoughts on role extension and 49% provided comments on changes in the workplace. The majority (61%) radiographers responding to the role extension question were concerned about potential problems associated with role extension; the biggest issues were that role extension should not be mandatory and that selection criteria for advanced practitioners should be stringent, with adequate time made available for training and study. The major change in the role of the radiographer has been the increased time dedicated to quality assurance tasks and administrative duties as well as more training required due to technological changes from film-screen to digital mammography. There is high interest in role extension by radiographers working in BreastScreen programs, provided that it is voluntary. The role of the radiographer within breast imaging in Australia is still evolving

  11. Impact of the digitalisation of mammography on performance parameters and breast dose in the Flemish Breast Cancer Screening Programme.

    Science.gov (United States)

    Timmermans, Lore; De Hauwere, An; Bacher, Klaus; Bosmans, Hilde; Lemmens, Kim; Bleyen, Luc; Van Limbergen, Erik; Martens, Patrick; Van Steen, Andre; Mortier, Griet; Van Herck, Koen; Thierens, Hubert

    2014-08-01

    To investigate the impact of digitalisation on performance parameters and breast dose of the Flemish Breast Cancer Screening Programme. Both computed (CR) and direct radiography (DR) are compared with screen-film mammography (SFM). Data from 975,673 mammographic examinations were collected from units which underwent digitalisation from SFM to CR (41 units) or DR (72 units) in the period 2005-2011. Performance indicators were obtained by consulting the Screening Programme database. Phantom and patient dosimetry data were acquired from the physical technical quality assurance of the programme. Digitalisation induced no significant change in cancer detection rate (CDR), percentage of ductal carcinomas in situ and percentage of breast cancers smaller than 1 cm. A decrease in false-positive results and third readings was observed, which was a time-related observation. After digitalisation, positive predictive value (PPV) increased and recall rates decreased. Compared with SFM, an increase of 30% in mean glandular dose (MGD) was found for CR, while a similar change in the opposite direction was found for DR. No major differences in performance parameters after digitalisation were found. Transition of SFM to CR resulted in a higher MGD and associated lower detection-over-induction ratio (DIR), while the change to DR induced an improvement of DIR. • Performance parameters showed no major differences after digitalisation to CR or DR. • Transition from SFM to CR results in a higher mean glandular dose. • Transition from SFM to DR results in a lower mean glandular dose.

  12. Are women getting relevant information about mammography screening for an informed consent: a critical appraisal of information brochures used for screening invitation in Germany, Italy, Spain and France.

    Science.gov (United States)

    Gummersbach, Elisabeth; Piccoliori, Giuliano; Zerbe, Cristina Oriol; Altiner, Attila; Othman, Cecile; Rose, Christine; Abholz, Heinz-Harald

    2010-08-01

    The aim was to find out if information brochures on mammography screening in Germany, Italy, Spain and France contain more information to facilitate informed consent than in similar studies carried out over the last few years in Sweden, Canada, USA and the UK, countries with different medical cultures. We generated a list of essential information items on mammography screening for the purpose of informed consent. We mostly used the same items of information as had been used in previous studies and analysed the information brochures of major national initiatives in Germany and France, and three brochures each from regionalized programmes in Italy and Spain. We cross-checked which of our items were covered in the brochures and if correct numbers were given. We found that the information brochures contained only about half of the information items we defined. Six of the eight brochures mentioned the reduction in breast-cancer fatalities. Four of the eight provided information on false positives, and four of the brochures highlighted the side-effects of radiation. The information on side-effects and risks provided by the brochures was generally of poor quality, and none of them referred to over diagnosis. When numbers were given, they were only indicated in terms of relative numbers. The information brochures currently being used in Germany, Italy, Spain and France are no better than the brochures analysed some years ago. Our results suggest that the providers of mammography screening programmes continue to conceal information from women that is essential when making an informed decision.

  13. The U.S. Online News Coverage of Mammography Based on a Google News Search.

    Science.gov (United States)

    Young Lin, Leng Leng; Rosenkrantz, Andrew B

    2017-12-01

    To characterize online news coverage relating to mammography, including articles' stance toward screening mammography. Google News was used to search U.S. news sites over a 9-year period (2006-2015) based on the search terms "mammography" and "mammogram." The top 100 search results were recorded. Identified articles were manually reviewed. The top 100 news articles were from the following sources: local news outlet (50%), national news outlet (24%), nonimaging medical source (13%), entertainment or culture news outlet (6%), business news outlet (4%), peer-reviewed journal (1%), and radiology news outlet (1%). Most common major themes were the screening mammography controversy (29%), description of a new breast imaging technology (23%), dense breasts (11%), and promotion of a public screening initiative (11%). For the most recent year, article stance toward screening mammography was 59%, favorable; 16%, unfavorable; and 25%, neutral. After 2010, there was an abrupt shift in articles' stances from neutral to both favorable and unfavorable. A wide range of online news sources addressed a range of issues related to mammography. National, rather than local, news sites were more likely to focus on the screening controversy and more likely to take an unfavorable view. The controversial United States Preventive Services Task Force guidelines may have influenced articles to take a stance on screening mammography. As such online news may impact public perception of the topic and thus potentially impact guideline adherence, radiologists are encouraged to maintain awareness of this online coverage and to support the online dissemination of reliable and accurate information. Copyright © 2017 The Association of University Radiologists. Published by Elsevier Inc. All rights reserved.

  14. Radiation dosage to the breast in well-women screening surveys

    Energy Technology Data Exchange (ETDEWEB)

    Asbury, D L; Barker, P G [University Hospital of South Manchester (UK)

    1975-12-01

    The D.H.S.S. is supporting research in several centres to determine the feasibility of establishing a nationwide Breast Cancer Screening Programme. This paper answers the questions 'What is the radiation dose produced by mammography, and is it safe'. In the context of well-women screening surveys a maximum skin dose of 2 R has been recommended. The variation of dose across the breast surface is recorded and the reasons for this enumerated. The lowest mean dose recorded with industrial quality film was 4.9 R, so that such fine-grain film cannot be used for this purpose. Doses within the recommended safety limit are achieved by the use of vacuum-packed film-screen combinations. The new rare-earth phosphor screens produced the lowest dose (0.2 R). There was no significant gonad dose. It is concluded that mammographic examination of well-women can be performed at safe radiation levels.

  15. Digital breast tomosynthesis plus synthesised images versus standard full-field digital mammography in population-based screening (TOSYMA): protocol of a randomised controlled trial.

    Science.gov (United States)

    Weigel, Stefanie; Gerss, Joachim; Hense, Hans-Werner; Krischke, Miriam; Sommer, Alexander; Czwoydzinski, Jörg; Lenzen, Horst; Kerschke, Laura; Spieker, Karin; Dickmaenken, Stefanie; Baier, Sonja; Urban, Marc; Hecht, Gerold; Heidinger, Oliver; Kieschke, Joachim; Heindel, Walter

    2018-05-14

    Development of digital breast tomosynthesis (DBT) provides a technology that generates three-dimensional data sets, thus reducing the pitfalls of overlapping breast tissue. Observational studies suggest that the combination of two-dimensional (2D) digital mammography and DBT increases diagnostic accuracy. However, because of duplicate exposure, this comes at the cost of an augmented radiation dose. This undesired adverse impact can be avoided by using synthesised 2D images reconstructed from the DBT data (s2D).We designed a diagnostic superiority trial on a high level of evidence with the aim of providing a comparison of screening efficacy parameters resulting from DBT+s2D versus the current screening standard 2D full-field digital mammography (FFDM) in a multicentre and multivendor setting on the basis of the quality-controlled, population-based, biennial mammography screening programme in Germany. 80 000 women in the eligible age 50-69 years attending the routine mammography screening programme and willing to participate in the TOSYMA trial will be assigned by 1:1 randomisation to either the intervention arm (DBT+s2D) or the control arm (FFDM) during a 12-month recruitment period in screening units of North Rhine-Westphalia and Lower Saxony. State cancer registries will provide the follow-up of interval cancers.Primary endpoints are the detection rate of invasive breast cancers at screening examination and the cumulative incidence of interval cancers in the 2 years after a negative examination. Secondary endpoints are the detection rate of ductal carcinoma in situ and of tumour size T1, the recall rate for assessment, the positive predictive value of recall and the cumulative 12-month incidence of interval cancers. An adaptive statistical design with one interim analysis provides the option to modify the design. This protocol has been approved by the local medical ethical committee (2016-132-f-S). Results will be submitted to international peer

  16. Review of Dosimetric Methods for Mammography in the UK Breast Screening Programme

    International Nuclear Information System (INIS)

    Young, K.C.; Ramsdale, M.L.; Bignell, F.

    1998-01-01

    The two methods used to monitor dose in mammography in the UK Breast Screening Programme are reviewed. The first is the measurement of mean glandular dose to a standard breast. The second is the estimation of mean glandular dose for individual women using the X ray exposure factors. Neither method takes account of variations in breast composition and the effect of this on estimates of glandular dose are reported. Applying the standard breast model using PMMA resulted in substantial overestimates of breast doses for women with large compressed breast thicknesses because they tend to have low glandular content. Conversely the use of post-exposure data to estimate the MGDs in women attending screening with large breasts resulted in underestimates of their doses unless the relatively low levels of glandularity were taken into account. When estimating the MGDs for breasts of different sizes, it is important that the models and methods used take account of the strong variation in breast composition with compressed thickness. (author)

  17. More misinformation on breast cancer screening

    OpenAIRE

    Kopans, Daniel B.

    2017-01-01

    Unfortunately, a great deal of misinformation has accumulated in the breast cancer screening literature that is based on flawed analyses in an effort to reduce access to screening. Quite remarkably, much of this has come from publications in previously highly respected medical journals. In several papers the intervention (mammography screening) is faulted yet the analyses provided no data on who participated in mammography screening, and which cancers were detected by mammography screening. I...

  18. What Do Patients Want to Know? Questions and Concerns Regarding Mammography Expressed Through Social Media.

    Science.gov (United States)

    Charlie, Abbas M; Gao, Yiming; Heller, Samantha L

    2017-12-05

    The purpose of this project is to identify questions and concerns patients have regarding breast cancer screening mammography to establish priorities in patient education and health care communication. A content analysis of posted questions (June 2010 to February 2017) containing the keywords mammogram and mammography was conducted on the social media question and answer website Quora (Quora Inc, Mountainview, California). Question topic, responses, and number of views were recorded. Comparisons were made by respondent type (medical professional or nonmedical professional) for screening recommendations and accompanying evidence. Descriptive statistics were employed to summarize the results. Overall, 197,620 views of mammography-related questions were identified, focused on 51 questions and 172 responses (51 of 172 [29.7%] by medical professionals [n = 25]; 121 of 172 [70.3%] by nonmedical professionals [n = 121]). Mammographic efficacy (16 of 51 [31.4%]) and screening guidelines (10 of 51 [19.6%]) were the most frequently queried topics. Overall, the majority of respondents were supportive of screening mammography. Most medical professionals recommended screening mammography starting at age 40, even after revisions in guidelines. Among nonmedical professionals, 4 of 22 (18.2%) were against screening mammography with less consensus regarding appropriate age of initial screen. Health society websites and journal articles were the most commonly referenced sources among medical and nonmedical professionals, respectively. A considerable interest in screening mammography guidelines and mammographic efficacy exists among users who seek health information on a social media question and answer website. Awareness of such platforms allows a unique opportunity for targeted health education and dissemination of accurate information, which may be able to reach a potentially untapped or hard-to-reach patient population. Copyright © 2017 American College of Radiology

  19. Screening mammography-detected cancers: the sensitivity of the computer-aided detection system as applied to full-field digital mammography

    International Nuclear Information System (INIS)

    Yang, Sang Kyu; Cho, Nariya; Ko, Eun Sook; Kim, Do Yeon; Moon, Woo Kyung

    2006-01-01

    We wanted to evaluate the sensitivity of the computer-aided detection (CAD) system for performing full-field digital mammography (FFDM) on the breast cancers that were originally detected by screening mammography. The CAD system (Image Checker v3.1, R2 Technology, Los Altos, Calif.) together with a full-field digital mammography system (Senographe 2000D, GE Medical Systems, Buc, France) was prospectively applied to the mammograms of 70 mammographically detected breast cancer patients (age range, 37-69; median age, 51 years) who had negative findings on their clinical examinations. The sensitivity of the CAD system, according to histopathologic findings and radiologic primary features (i.e, mass, microcalcifications or mass with microcalcifications) and also the false-positive marking rate were then determined. The CAD system correctly depicted 67 of 70 breast cancer lesions (97.5%). The CAD system marked 29 of 30 breast cancers that presented with microcalcifications only (sensitivity 96.7%) and all 18 breast cancers the presented with mass together with microcalcifications (sensitivity 100%). Twenty of the 22 lesions that appeared as a mass only were marked correctly by the CAD system (sensitivity 90.9%). The CAD system correctly depicted all 22 lesions of ductal carcinoma in situ (sensitivity: 100%), all 13 lesions of invasive ductal carcinoma with ductal carcinoma in situ (sensitivity: 100%) and the 1 lesion of invasive lobular carcinoma (sensitivity: 100%). Thirty one of the 34 lesions of invasive ductal carcinoma were marked correctly by the CAD system (sensitivity: 91.8%). The rate of false-positive marks was 0.21 mass marks per image and 0.16 microcalcification marks per image. The overall rate of false-positive marks was 0.37 per image. The CAD system using FFDM is useful for the detection of asymptomatic breast cancers, and it has a high overall tumor detection rate. The false negative cases were found in relatively small invasive ductal carcinoma

  20. Screening mammography-detected cancers: the sensitivity of the computer-aided detection system as applied to full-field digital mammography

    Energy Technology Data Exchange (ETDEWEB)

    Yang, Sang Kyu; Cho, Nariya; Ko, Eun Sook; Kim, Do Yeon; Moon, Woo Kyung [College of Medicine Seoul National University and The Insititute of Radiation Medicine, Seoul National University Research Center, Seoul (Korea, Republic of)

    2006-04-15

    We wanted to evaluate the sensitivity of the computer-aided detection (CAD) system for performing full-field digital mammography (FFDM) on the breast cancers that were originally detected by screening mammography. The CAD system (Image Checker v3.1, R2 Technology, Los Altos, Calif.) together with a full-field digital mammography system (Senographe 2000D, GE Medical Systems, Buc, France) was prospectively applied to the mammograms of 70 mammographically detected breast cancer patients (age range, 37-69; median age, 51 years) who had negative findings on their clinical examinations. The sensitivity of the CAD system, according to histopathologic findings and radiologic primary features (i.e, mass, microcalcifications or mass with microcalcifications) and also the false-positive marking rate were then determined. The CAD system correctly depicted 67 of 70 breast cancer lesions (97.5%). The CAD system marked 29 of 30 breast cancers that presented with microcalcifications only (sensitivity 96.7%) and all 18 breast cancers the presented with mass together with microcalcifications (sensitivity 100%). Twenty of the 22 lesions that appeared as a mass only were marked correctly by the CAD system (sensitivity 90.9%). The CAD system correctly depicted all 22 lesions of ductal carcinoma in situ (sensitivity: 100%), all 13 lesions of invasive ductal carcinoma with ductal carcinoma in situ (sensitivity: 100%) and the 1 lesion of invasive lobular carcinoma (sensitivity: 100%). Thirty one of the 34 lesions of invasive ductal carcinoma were marked correctly by the CAD system (sensitivity: 91.8%). The rate of false-positive marks was 0.21 mass marks per image and 0.16 microcalcification marks per image. The overall rate of false-positive marks was 0.37 per image. The CAD system using FFDM is useful for the detection of asymptomatic breast cancers, and it has a high overall tumor detection rate. The false negative cases were found in relatively small invasive ductal carcinoma.

  1. Mammography: an update of the EUSOBI recommendations on information for women

    OpenAIRE

    Sardanelli, Francesco; Fallenberg, Eva M.; Clauser, Paola; Trimboli, Rubina M.; Camps-Herrero, Julia; Helbich, Thomas H.; Forrai, Gabor

    2016-01-01

    Abstract This article summarises the information to be offered to women about mammography. After a delineation of the aim of early diagnosis of breast cancer, the difference between screening mammography and diagnostic mammography is explained. The need to bring images and reports from the previous mammogram (and from other recent breast imaging examinations) is highlighted. Mammography technique and procedure are described with particular attention to discomfort and pain experienced by a sma...

  2. Positive predictive values by mammographic density and screening mode in the Norwegian Breast Cancer Screening Program.

    Science.gov (United States)

    Moshina, Nataliia; Ursin, Giske; Roman, Marta; Sebuødegård, Sofie; Hofvind, Solveig

    2016-01-01

    To investigate the probability of breast cancer among women recalled due to abnormal findings on the screening mammograms (PPV-1) and among women who underwent an invasive procedure (PPV-2) by mammographic density (MD), screening mode and age. We used information about 28,826 recall examinations from 26,951 subsequently screened women in the Norwegian Breast Cancer Screening Program, 1996-2010. The radiologists who performed the recall examinations subjectively classified MD on the mammograms into three categories: fatty (70%). Screening mode was defined as screen-film mammography (SFM) and full-field digital mammography (FFDM). We examined trends of PPVs by MD, screening mode and age. We used logistic regression to estimate odds ratio (OR) of screen-detected breast cancer associated with MD among women recalled, adjusting for screening mode and age. PPV-1 and PPV-2 decreased by increasing MD, regardless of screening mode (p for trend breasts. Among women recalled, the adjusted OR of breast cancer decreased with increasing MD. Compared with women with fatty breasts, the OR was 0.90 (95% CI: 0.84-0.96) for those with medium dense breasts and 0.85 (95% CI: 0.76-0.95) for those with dense breasts. PPVs decreased by increasing MD. Fewer women needed to be recalled or undergo an invasive procedure to detect one breast cancer among those with fatty versus dense breasts in the screening program in Norway, 1996-2010. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.

  3. Introduction of computed radiography in two mammography services: image quality and dose analysis

    International Nuclear Information System (INIS)

    Jakubiak, Rosangela R.; Gamba, Humberto R.; Ramos, Maria M.; Faversani, Gislene G.; Peixoto, Joao E.

    2008-01-01

    This study has evaluated the impact of the introduction of CR technology in the routine of two mammography services operating with Lorad Affinity X-ray units and CR Fuji Profect One system. Mean glandular dose was determined to set Automatic Exposure Control parameters according to optimal image quality. Reject analysis of patient images was made to establish the overall impact in routine work. As regards to dose evaluation, the results show that in 44% of mammography exams the MGD were above action levels. It is due to inadequate AEC adjustment and insufficient training of the staff in operating CR systems. In addition, common errors with screen/film systems like wrong breast positing and selection of exposure parameters, as well as X-ray unit failures like insufficient anti scatter grid movement still occurs. This is an indication that ongoing efforts should be concentrated in the constancy of AEC adjustment for CR image plates and staff training. Until now, brazilian health authorities did not implement any program to evaluate digital systems performance, but efforts are being done in order to provide guidelines to breast screening aiming the control of breast dose compatible with optimal image quality. (author)

  4. Noise of screen-film systems: origins and components

    Energy Technology Data Exchange (ETDEWEB)

    Kuhn, H

    1983-01-01

    When using the more sensitive rare-earth intensifying screens in radiography applying the screen-film system, one has to cope with an increase in quantum noise. Measurement of Wiener spectra will help to determine the noise of the film. With an appropriate apparatus, the noise spectra of screen-film systems of different sensitivity have been ascertained and compared with theoretical assessments. The integral noise made up of the components film noise, screen noise and quantum noise have been thoroughly analysed. Adequate choice of radiographic conditions (such as modification of film exposure time via the screen, change of tube voltage) will affect the number of absorbed X-ray quanta in the luminous substance and thus the quantum noise which, as was found out, largely contributes to the integral noise together with another factor, graininess of the film. The study shows that although quantum noise has to be cut back, this should not be done at any price, and due regard must be paid to other factors influencing the image quality of the system, such as contrast and MTF.

  5. Breast cancer detected in screening mammography: a comparative analysis of the cases involving women aged 40 to 49 years and 50 to 64 years

    International Nuclear Information System (INIS)

    Echevarria, J.J.; Lopez, J.A.; Segovia, M.C.; Rodriguez, M.; Zabalza, I.; Garcia, M.

    1998-01-01

    To determine and compare the prognostic criteria (tumor, size, lymph node involvement, clinical staging and histological type and grade) for breast neoplasms detected at screening mammography in women 40 to 49 and 50 to 64 years of age. We review a total of 216 unelected cases of breast carcinoma diagnosed in our hospital, 109 discovered at screening mammography (45 in women aged 40 to 40 years and 64 in women aged 50 to 64 years). We found no statistically significant differences between the two age groups with respect to tumor size, lymph node involvement or clinical staging. In all, 64.4% and 61.6% of the carcinomas detected in 40 to 49-year-old women and in 50 to 64-year-old women, respectively, corresponded to clinical stages 0 and 1. Nor did we observe significant differences with respect to the histological type or grade. Given the similarity in the major prognostic criteria for the neoplasms diagnosed in both age groups, we consider that the performance of screening mammography in women aged 40 to 49 years allows the detection of breast carcinomas at stages as early as those in which these lesions are detected in women aged 50 to 64 years. (Author) 24 refs

  6. Mammography activity in Norway 1983 to 2008

    DEFF Research Database (Denmark)

    Lynge, Elsebeth; Braaten, Tonje; Njor, Sisse H

    2011-01-01

    In Norway, an organized screening mammography program, the Norwegian Breast Cancer Screening Program (NBCSP) started in four counties in 1996 and became nationwide in 2004. We collected data on pre-program screening activity, and in view of this activity we evaluated the potential impact...... of the program on breast cancer mortality in Norway....

  7. Exploring the potential of context-sensitive CADe in screening mammography

    International Nuclear Information System (INIS)

    Tourassi, Georgia D.; Mazurowski, Maciej A.; Harrawood, Brian P.; Krupinski, Elizabeth A.

    2010-01-01

    Purpose: Conventional computer-assisted detection (CADe) systems in screening mammography provide the same decision support to all users. The aim of this study was to investigate the potential of a context-sensitive CADe system which provides decision support guided by each user's focus of attention during visual search and reporting patterns for a specific case. Methods: An observer study for the detection of malignant masses in screening mammograms was conducted in which six radiologists evaluated 20 mammograms while wearing an eye-tracking device. Eye-position data and diagnostic decisions were collected for each radiologist and case they reviewed. These cases were subsequently analyzed with an in-house knowledge-based CADe system using two different modes: Conventional mode with a globally fixed decision threshold and context-sensitive mode with a location-variable decision threshold based on the radiologists' eye dwelling data and reporting information. Results: The CADe system operating in conventional mode had 85.7% per-image malignant mass sensitivity at 3.15 false positives per image (FPsI). The same system operating in context-sensitive mode provided personalized decision support at 85.7%-100% sensitivity and 0.35-0.40 FPsI to all six radiologists. Furthermore, context-sensitive CADe system could improve the radiologists' sensitivity and reduce their performance gap more effectively than conventional CADe. Conclusions: Context-sensitive CADe support shows promise in delineating and reducing the radiologists' perceptual and cognitive errors in the diagnostic interpretation of screening mammograms more effectively than conventional CADe.

  8. Time for a re-evaluation of mammography in the young? Results of an audit of mammography in women younger than 40 in a resource restricted environment.

    Science.gov (United States)

    Taylor, Liezel; Basro, Sarinah; Apffelstaedt, Justus P; Baatjes, Karin

    2011-08-01

    Mammography in younger women is considered to be of limited value. In a resource restricted environment without access to magnetic resonance imaging (MRI) and with a high incidence of breast cancer in the young, mammography remains an important diagnostic tool. Recent technical advances and better regulation of mammography make a reassessment of its value in these conditions necessary. Data of all the mammograms performed at a tertiary hospital and private breast clinic between January 2003 and July 2009 in women less than 40 years of age were collected. Indications were the presence of a mass, follow-up after primary cancer therapy, and screening for patients perceived at high risk due to a family history or the presence of atypical hyperplasia. Data acquired were as follows: Demographics, prior breast surgery, indication for mammography, outcome of mammography, diagnostic procedures, and their results. Of 2,167 mammograms, 393 were performed for a palpable mass, diagnostic mammography. In these, the overall cancer detection rate was 40%. If the mammography was reported as breast imaging reporting and data system (BIRADS(®)) 5 versus BIRADS(®) 3 and 4 versus BIRADS(®) 1 and 2, a final diagnosis of malignancy was established in 96, 48, and 5%, respectively. Of 367 mammograms done for the follow-up after primary treatment of breast cancer, seven cancers were diagnosed for a detection rate of 1.9%. Of 1,312 mammograms performed for screening, the recall rate was 4%; the biopsy rate 2%, and the cancer diagnosis rate 3/1,000 examinations. In contrast to past series, this series has shown that recent advances in mammography have made it a useful tool in the management of breast problems in young women, notably in a resource-restricted environment. Women for screening should be selected carefully.

  9. Film-screen digital radiography

    International Nuclear Information System (INIS)

    Schwenker, R.P.; Eger, H.

    1985-01-01

    The excellent performance of the digital film-screen system as a receptor for projection radiographic data is discussed. An experimental system for obtaining high quality digital radiographic data by laser scanning radiographic films is described. This system is being used to evaluate the clinical utility of various digital image processing algorithms. Future plans include an investigation of quantitative analysis of projection radiographic data. Digital data obtained by film scanning can be used with digital image archiving and communications systems. (author)

  10. Breast cancer screening implementation and reassurance

    DEFF Research Database (Denmark)

    Østerø, J; Siersma, Volkert Dirk; Brodersen, John

    2013-01-01

    difference in reported psychosocial aspects had disappeared or been reduced because of the nationwide screening implementation. METHODS: The 1000 women included in the previous survey were posted part I of the questionnaire Consequences of Screening in Breast Cancer (COS-BC1) in August 2011, nearly 5 years......BACKGROUND: Women not offered screening mammography reported higher levels of negative psychosocial aspects than women offered screening. This was demonstrated in a questionnaire survey where 1000 women were included: 500 women living in areas where the public authorities had never offered...... screening mammography and 500 women living in areas where women had been invited to screening mammography for >10 years. After this baseline survey, nationwide screening mammography was implemented. The aim of this follow-up study was to resurvey the 1000 women and to investigate if the identified...

  11. The significance of X-ray mammography for breast cancer screening

    International Nuclear Information System (INIS)

    Schulz-Wendtland, R.; Kraemer, S.; Doeinghaus, K.; Saebel, M.; Lang, N.; Bautz, W.

    1997-01-01

    One high-priority health problem in our society are the high, age-specifically standardized mortality rates of breast cancer. Breast-conserving therapies are increasingly applied today whenever appropriate, as the patient outcome depends less on the local size of the tumor than on the existing micrometastases and general spreading of the tumor in terms of a systemic tumor lesion at the time of diagnosis and primary therapy. Among the available diagnostic methods, X-ray mammography is the modality of choice for detection of small, pre-clinical carcinoma or pre-invasive stages. Although one should not overestimate the true correct findings in detection of tumors less than 1 cm of size, the proportion of correct findings indicating T1-tumors or minimal cancer obtained in multiple screening projects is surprising. The fact that the number of detected cases involving the lymph nodes is 50% in patients with clinical symptoms and only 20% or even less in diognoses obtained by screening gives reason enough to speak of ''early detection'' in the latter case. Finally, the results of the HIP study, (reduction of mortality rates for women over 50 by 40%), and of the Oestergoetland study (for women between 40 and 70 years of age, 31%) are very convincing. Furthermore, a meta-analysis on the value of breast cancer screening reveals a mortality reduction of 22% in women between 40 and 49 years of age. Further improvement of the mammographic method and quality control in medical evaluation hopefully will contribute to more widespread screening activities also in Germany, and hence to a further reduction of mortality rates. (Orig./vhe) [de

  12. Effects of a risk-based online mammography intervention on accuracy of perceived risk and mammography intentions.

    Science.gov (United States)

    Seitz, Holli H; Gibson, Laura; Skubisz, Christine; Forquer, Heather; Mello, Susan; Schapira, Marilyn M; Armstrong, Katrina; Cappella, Joseph N

    2016-10-01

    This experiment tested the effects of an individualized risk-based online mammography decision intervention. The intervention employs exemplification theory and the Elaboration Likelihood Model of persuasion to improve the match between breast cancer risk and mammography intentions. 2918 women ages 35-49 were stratified into two levels of 10-year breast cancer risk (<1.5%; ≥1.5%) then randomly assigned to one of eight conditions: two comparison conditions and six risk-based intervention conditions that varied according to a 2 (amount of content: brief vs. extended) x 3 (format: expository vs. untailored exemplar [example case] vs. tailored exemplar) design. Outcomes included mammography intentions and accuracy of perceived breast cancer risk. Risk-based intervention conditions improved the match between objective risk estimates and perceived risk, especially for high-numeracy women with a 10-year breast cancer risk ≤1.5%. For women with a risk≤1.5%, exemplars improved accuracy of perceived risk and all risk-based interventions increased intentions to wait until age 50 to screen. A risk-based mammography intervention improved accuracy of perceived risk and the match between objective risk estimates and mammography intentions. Interventions could be applied in online or clinical settings to help women understand risk and make mammography decisions. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  13. Image quality and patient exposure in mammography, tomography, angiography, and bone radiography

    International Nuclear Information System (INIS)

    Haus, A.G.; Rossmann, K.; Doi, K.; Chiles, J.T.

    1975-01-01

    In diagnostic radiology, the physical factors affecting image quality and patient exposure are complex and must be studied for each individual procedure. They are a function of recording system unsharpness, geometric unsharpness, image noise, and of the shape, size, and absorption properties of the anatomic part radiographed and the lesion to be detected. The choice of recording system has a significant effect on image quality, and the speed of the recording system is directly related to patient exposure for each procedure. In this presentation, the complexities involved in the selection of recording systems for four radiologic procedures are discussed. We describe in detail our most recent work on mammography with the Lo-Dose system, whereby a significant reduction in exposure may not reduce, but may even increase the diagnostic accuracy by reducing geometric unsharpness. We also describe several examples: (a) in tomography, image resolution is not decreased and diagnostic certainty is affected by a change from a medium-speed screen to a high-speed screen recording system (patient exposure is reduced by a factor of 2); (b) in fine-detail skeletal radiography, the diagnostic information is increased significantly by a change from a conventional screen-film technique to a non-screen technique with fine-grain film and optical magnification, but at the cost of increased patient exposure; and (c) in cerebral angiography, diagnostic information can be increased by use of a screen-film recording system of higher resolution, but lower speed for imaging of small blood vessels. Modulation Transfer Functions and clinical examples are used to illustrate each procedure. (U.S.)

  14. Image quality and patient exposure in mammography, tomography, angiography and bone radiography

    International Nuclear Information System (INIS)

    Haus, A.G.; Rossmann, K.; Doi, K.; Chiles, J.T.

    1975-01-01

    In diagnostic radiology, the physical factors affecting image quality and patient exposure are complex and must be studied for each individual procedure. They are a function of recording system unsharpness, geometric unsharpness, image noise, and of the shape, size, and absorption properties of the anatomic part radiographed and the lesion to be detected. The choice of recording system has a significant effect on image quality, and the speed of the recording system is directly related to patient exposure for each procedure. This paper discusses the complexities involved in the selection of recording systems for four radiologic procedures. The authors describe in detail their most recent work on mammography with the Lo-Dose system, whereby a significant reduction in exposure may not reduce, but may even increase, the diagnostic accuracy by reducing geometric unsharpness. We also describe several examples: (a) in tomography, image resolution is not decreased and diagnostic certainty is affected by a change from a medium-speed screen to a high-speed screen recording system (patient exposure is reduced by a factor of 2); (b) in fine-detail skeletal radiography, the diagnostic information is increased significantly by a change from a conventional screen-film technique to a non-screen technique with fine-grain film and optical magnification, but at the cost of increased patient exposure; and (c) in cerebral angiography, diagnostic information can be increased by use of a screen-film recording system of higher resolution, but lower speed for imaging of small blood vessels. Modulation transfer functions and clinical examples are used to illustrate each procedure. (author)

  15. Mammography use among women aged 18-39 years in the United States.

    Science.gov (United States)

    Qin, Jin; White, Mary C; Sabatino, Susan A; Febo-Vázquez, Isaedmarie

    2018-04-01

    Recommendations for breast cancer screening using mammography target asymptomatic women aged ≥ 40 years who are not at increased risk for breast cancer. Evidence is not available to demonstrate benefits of screening with mammography at younger ages, and little is known about mammography use among younger women. This study described mammography use among women aged 18-39 years. We analyzed data from the 2011-2015 National Survey of Family Growth, an in-person survey of a nationally representative sample of the U.S. household population. We estimated the prevalence of ever receiving a mammogram and examined reasons for the first mammograms among women aged 18-39 years without personal cancer history (n = 8324). We classified the first mammogram as a screening examination if it was performed either as part of a routine exam or because of family history of cancer. Among women aged 18-39 years, 14.3% (95% CI 13.2-15.4) reported ever having a mammogram. Prevalence of mammography use was highest among women aged 35-39 years (31.0%, 95% CI 27.8-34.5), and was higher among non-Hispanic black women than in other race/ethnicity groups. Women with a family history of breast cancer reported a higher prevalence of mammography use than women without this family history. For both women with and without a family history of breast cancer, about half of all first mammograms were performed for screening reasons. Among U.S. women aged 18-39 years with no personal cancer history, one in seven reported having received a mammogram. Women with no family history of breast cancer were as likely as those with a family history to initiate breast cancer screening with mammography before age 40. Our findings provide evidence that supports further research to examine factors that prompt young women to receive screening mammograms.

  16. Descriptive study of the quality control in mammography

    International Nuclear Information System (INIS)

    Gaona, E.; Perdigon C, G.M.; Casian C, G.A.; Azorin N, J.; Diaz G, J.A.I.; Arreola, M.

    2005-01-01

    The goal of mammography is to provide contrast between a lesion that is possible residing within the breast and normal surrounding tissue. Quality control is essential for maintaining the contrast imaging performance of a mammography system and incorporate tests that are relevant in that they are predictive of future degradation of contrast imaging performance. These tests will also be done at frequency that is high enough to intercept most drifts in quality imaging or performance before they become diagnostically significant. The quality control study has as objective to describe the results of the assessment of quality imaging elements (film optical density, contrast (density difference), uniformity, resolution and noise) of 62 mammography departments without quality control program and comparison these results with a mammography reference department with a quality control program. When comparing the results they allow seeing the clinical utility of to have a quality control program to reduce the errors of mammography interpretation. (Author)

  17. Image quality control of mammography equipment -Mammography System MX-300- of the Teachers Hospital of UNSA and dose measurement in breasts with radiographic films; Control de calidad de imagen del equipo de mamografia -Mammography System MX-300- del Hospital de Docentes de la UNSA y medicion de dosis en mamas con peliculas radiograficas

    Energy Technology Data Exchange (ETDEWEB)

    Quispe F, L. K.; Vega R, J., E-mail: karinaqflores839@gmail.com [Universidad Nacional de San Agustin, Escuela Profesional de Fisica, Arequipa (Peru)

    2015-10-15

    This work is part of medical imaging for the evaluation of quality. Will have an accredited breast phantom Rmi-156 that allows evaluating the image quality of mammography equipment and through a series of techniques and processes that will submit to mammography films we obtain characteristic curves, which allows to evaluate different parameters that will serve for our study. Images were acquired with different k Vp and m As of the equipment, also with different thicknesses of the breast phantom. Also we want to use the lowest possible dose for obtaining our images. In this paper we develop a simple protocol that aims to unify the conditions under which are acquired the images for later evaluation. By obtaining these characteristic curves demonstrate that the Kodak film is the most suitable for our study because it requires lower dose for obtaining our images. (Author)

  18. X-ray exposures given with various combinations of film and screen

    International Nuclear Information System (INIS)

    Schlenker, R.A.; Kirsh, I.E.

    A comparison of entrance exposure doses of patients for various film and screen combinations and xeroradiographs showed that moderate speed screen and film gave exposures 4 to 7 times greater than fast film and screen and that xeroradiographs produced exposures 20 to 40 times greater than fast film and screen. Xeroradiographs produced table top incident exposures which exceeded Illinois Department of Health limits, while conventional film-screen combinations did not. (U.S.)

  19. Practical determination of sensitometric properties of medical film-screen combinations

    International Nuclear Information System (INIS)

    Vassileva, J.; Ibrachim, K.

    2000-01-01

    The aim of the study is to to compare different sensitometric techniques for medical film-screen systems and to chose the optimal one for practical use in a clinical environment and to compare the sensitometric properties of different film-screen combinations practically used for chest radiography. The measurement have been performed using TUR D800-3 radiographic installation with twelve-pulse generator and DRX 124/30/60 oDw tube. The following screens and cassettes have been investigated: VARIMEX (Poland) with PERLUX screens (Germany); DuPomt cassette with QFD screens; Kodak X-Omatic LW cassette with Lanex Regular screens. They have been combined with 4 types of films: Sterling Cronex4 (blue); Agfa CP-BU New (blue); Agfa CP-G Plus (ortho) and Kodak TMG-RA (ortho). All cassettes have been examined for light tightness and screen-film contact and all film types have been checked for the compatibility with the safe lights in the darkroom. To simulate a patient for a chest radiography standard LucAl chest phantom has been designed. The measurements show that: 1) Sensitivity of Kodak cassette with green emitting rare-earth Kodak Lanex Regular screens combined with ortho Kodak film is highest; 2) From two emitting screens - PERLUX and QFD. both combined with blue sensitive films, QFD is 3.6 times more sensitive. 3) Films Agfa CP-BU New and Cronex 4 are of the same sensitivity class but the first has higher contrast. 4) The use of ortho-chromatic films in combination with PERLUX or QGD blue emitting screens results in a considerable loss of sensitivity

  20. Should previous mammograms be digitised in the transition to digital mammography?

    International Nuclear Information System (INIS)

    Taylor-Phillips, S.; Gale, A.G.; Wallis, M.G.

    2009-01-01

    Breast screening specificity is improved if previous mammograms are available, which presents a challenge when converting to digital mammography. Two display options were investigated: mounting previous film mammograms on a multiviewer adjacent to the workstation, or digitising them for soft copy display. Eight qualified screen readers were videotaped undertaking routine screen reading for two 45-min sessions in each scenario. Analysis of gross eye and head movements showed that when digitised, previous mammograms were examined a greater number of times per case (p=0.03), due to a combination of being used in 19% more cases (p=0.04) and where used, looked at a greater number of times (28% increase, p=0.04). Digitising previous mammograms reduced both the average time taken per case by 18% (p=0.04) and the participants' perceptions of workload (p < 0.05). Digitising previous analogue mammograms may be advantageous, in particular in increasing their level of use. (orig.)

  1. Managed Care Penetration and the Use of Screening Mammography by Uninsured Women

    National Research Council Canada - National Science Library

    Garg, Pushkal

    2003-01-01

    ..., and increased waiting times for mammography. In this study, we examined whether there was an association between managed care penetration and rates of mammography among uninsured women between 50 and 64 years of age...

  2. Quality control of mammography departments in Slovakia

    International Nuclear Information System (INIS)

    Horvathova, M.; Nikodemova, D.

    2007-01-01

    Complete test of publication follows. Considering the fact that mammary gland is the most sensitive organ to ionizing radiation, the Commission of the Ministry of Health of SR for QA in radiology organized a pilot two-run country wide audit conducted in 42 mammography departments that have met the beforehand criteria. During the audit the methods for establishing the individual parameters in technical and clinical part of quality assurance in mammography were elaborated and implemented. Technical and clinical parameters of the imaging process that mostly affect the quality of diagnostic information were followed up. These parameters included: the object thickness compensation, optical density deviation, evaluation of the film quality by means of special phantom, etc. Important measurement of ESDs at participating departments enabled to compare the radiation load of mammography patients in Slovakia with reference values in European guidelines. The uniform standard method for QA at mammography departments was elaborated and published as the regulation of the Ministry of Health for performance of preventive mammography examinations in SR. The presented results show the improved quality of mammography examinations due to regular check-ups of technical and clinical parameters and fulfilment of the required values in all parameters. The audit results are the basis for continuous quality assessment of mammography departments as a main prerequisite for conducting preventive examinations and for health insurance purposes.

  3. Determination of mean glandular dose on patients and phantom in X-ray mammography

    International Nuclear Information System (INIS)

    Avramova-Cholakova, S.; Vassileva, J.

    2008-01-01

    The statistics of breast cancer rate in Bulgaria show a tendency towards increase of the morbidity from this disease. Last years campaigns against breast cancer are organized yearly. This leads to an increased number of screening and diagnostic mammograms that are made in the country. The dose associated with the examination is very low but not slightingly small. The glandular tissue in the breast is considered to be the most sensitive in relation to the radiation exposure. Several publications propose different methods, measurement set up or conversion coefficients for the calculation of the mean glandular dose (MGD) delivered to the breast during the X-ray examination. The question about the standardization of the measurement procedures arises since the differences in the results obtained using different methodologies may be quite big. The aim of this work is to develop a standard procedure for the measurement of MGD based on the recommendations mentioned in the European protocol on dosimetry in mammography, the European protocol for the quality control of the physical and technical aspects of mammography screening and the Code of practice: TRS 457 of the IAEA. Five contemporary film-screen mammography units were included in this study. Attention should be paid to the measurement set up. The reference point is chosen 6 cm from the chest wall edge laterally centered. If an ionization chamber is used for dose measurements the compression plate should be placed in close contact with it. If solid state detectors are used the compression plate should be put away from the detector and the output recalculated like if the plate is near the detector. The conversion coefficients for age dependence are not used in this study as not appropriate for the population included in it. PMMA measurements for the determination of diagnostic reference levels could be used but more correct results would be obtained with patient measurements

  4. Online information about risks and benefits of screening mammography in 10 European countries: An observational Web sites analysis.

    Science.gov (United States)

    Spagnoli, Laura; Navaro, Monica; Ferrara, Pietro; Del Prete, Viola; Attena, Francesco

    2018-06-01

    Most publications about breast cancer do not provide accurate and comprehensive information, giving few or no data about risk/benefit ratios. We conducted a comparative study among 10 European countries about health information on breast cancer screening, assessing the first 10 Web sites addressing the general public that appeared following an Internet search.With the help of medical residents involved in the EuroNet MRPH Association, we analyzed the first 30 results of an Internet search in 10 European countries to determine the first 10 sites that offered screening mammography. We searched for the following information: source of information, general information on mammography and breast cancer screening, potential harms and risks (false positives, false positives after biopsy, false negatives, interval cancer, overdiagnosis, lead-time bias, and radiation exposure), and potential benefits (reduced mortality and increased survival).The United Kingdom provided the most information: 39 of all 70 possible identified risks (56%) were reported on its sites. Five nations presented over 35% of the possible information (United Kingdom, Spain, France, Ireland, and Italy); the others were under 30% (Portugal, Poland, Slovenia, Netherlands, and Croatia). Regarding the benefits, sites offering the most complete information were those in France (95%) and Poland (90%).Our results suggest that, despite consensus in the scientific community about providing better information to citizens, further efforts are needed to improve information about breast cancer screening. That conclusion also applies to countries showing better results. We believe that there should be greater coordination in this regard throughout Europe.

  5. Teaching atlas of mammography

    International Nuclear Information System (INIS)

    Tabar, L.; Dean, P.B.

    1985-01-01

    The illustrated case reports in this teaching atlas cover practically the entire range of possible pathological changes and are based on in-patient case material and 80,000 screening documents. The two basic approaches, - detection and analysis of changes -, are taught comprehensively and in great detail. A systematic procedure for analysing the mammographies, in order to detect even the very least changes, and its practical application is explained using mammographies showing unclear findings at first sight. A system of coordinates is presented which allows precise localisation of the changes. Exercises for practising the technique of identifying the pathological changes round up the methodolical chapters. Additional imaging technical enhancements and detail enlargements are of great help in interpreting the findings. The specific approach adopted for this teaching atlas is a 'reverse procedure', which leaves the beaten track and starts with analysing the mammographies and evaluating the radiographic findings, in order to finally derive the diagnosis. (orig./CB) [de

  6. Analysis of utilization patterns and associated costs of the breast imaging and diagnostic procedures after screening mammography

    Directory of Open Access Journals (Sweden)

    Vlahiotis A

    2018-03-01

    Full Text Available Anna Vlahiotis,1 Brian Griffin,2 A Thomas Stavros,3 Jay Margolis1 1Value Based Care, Outcomes Research, Truven Health Analytics, an IBM Company, Bethesda, MD USA; 2Value Based Care, Outcomes Research, Truven Health Analytics, an IBM Company, Newark, NJ, USA; 3Seno Medical Instruments, Inc., San Antonio, TX, USA Background: Little data exist on real-world patterns and associated costs of downstream breast diagnostic procedures following an abnormal screening mammography or clinical exam.Objectives: To analyze the utilization patterns in real-world clinical settings for breast imaging and diagnostic procedures, including the frequency and volume of patients and procedures, procedure sequencing, and associated health care expenditures.Materials and methods: Using medical claims from 2011 to 2015 MarketScan Commercial and Medicare Databases, adult females with breast imaging/diagnostic procedures (diagnostic mammography, ultrasound, molecular breast imaging, tomosynthesis, magnetic resonance imaging, or biopsy other than screening mammography were selected. Continuous health plan coverage without breast diagnostic procedures was required for ≥13 months before the first found breast diagnostic procedure (index event, with a 13-month post-index follow-up period. Key outcomes included diagnostic procedure volumes, sequences, and payments. Results reported descriptively were projected to provide US national patient and procedure volumes.Results: The final sample of 875,526 patients was nationally projected to 12,394,432 patients annually receiving 8,732,909 diagnostic mammograms (53.3% of patients, 6,987,399 breast ultrasounds (42.4% of patients, and 1,585,856 biopsies (10.3% of patients. Following initial diagnostic procedures, 49.4% had second procedures, 20.1% followed with third procedures, and 10.0% had a fourth procedure. Mean (SD costs for diagnostic mammograms of US$349 ($493, ultrasounds US$132 ($134, and biopsies US$1,938 ($2,343 contributed

  7. Managed Care Penetration and the Use of Screening Mammography by Uninsured Women

    National Research Council Canada - National Science Library

    Garg, Pushkal

    2002-01-01

    ..., and increased waiting times for mammography. In this study we propose to examine whether there is an association between managed care penetration and rates of mammography among uninsured women between 50 and 64 years of age...

  8. Evaluation of mammographic screen-film combinations in the clinic

    International Nuclear Information System (INIS)

    Shepard, J.

    1987-01-01

    Six commercially available mammographic film-screen combinations were evaluated in the authors department. Film speed and contrast was measured by obtaining H and D curves. Sensitivity to processing conditions was determined by analyzing changes in the H and D cures as a function of development time and temperature and by examining artifacts in a uniformly exposed film. Radiographs of a 0.5 0 star pattern show relative screen unsharpness. The speed of the film-screen combination is indicated by calculating patient dose necessary to produce optical densities of 1.5 through phantom thicknesses of 3.5 cm of acrylic. Images of a modified RMI detail phantom obtained with each film-screen combination were evaluated by 22 radiologist. Results indicate the physicians' overall preference

  9. Evaluation of the "Angelina Jolie Effect" on Screening Mammography Utilization in an Academic Center.

    Science.gov (United States)

    Huesch, Marco D; Schetter, Susann; Segel, Joel; Chetlen, Alison

    2017-08-01

    The aim of this study was to understand the impact on screening mammography at our institution, comparing weekly utilization in the 2 years before and the 2 years after Ms Angelina Jolie disclosed in the New York Times on May 13, 2013, that she had had a prophylactic double mastectomy. All 48,110 consecutive screening mammograms conducted at our institution between May 16, 2011, and May 16, 2015, were selected from our electronic medical record system. We used interrupted time series statistical models and graphical methods on utilization data to understand utilization changes before and after Ms Jolie's news. The graphed trend of weekly screening mammogram utilization failed to show changes around the time of interest. Analytical models and statistical tests also failed to show a step change increase or acceleration of utilization around May 2013. However, graphical and time series analyses showed a flattening of utilization in the middle of 2014. In our well-powered analysis in a large regional breast imaging center, we found no support for the hypothesis that this celebrity news drove increased screening. Copyright © 2017 American College of Radiology. Published by Elsevier Inc. All rights reserved.

  10. Breast cancer incidence and mortality in the Nordic capitals, 1970-1998. Trends related to mammography screening programmes

    International Nuclear Information System (INIS)

    Toernberg, Sven; Kemetli, Levent; Anttila, Ahti; Hakama, Matti; Nystroem, Lennarth

    2006-01-01

    The aim of the present study was to relate the time trends in breast cancer incidence and mortality to the introduction of mammography screening in the Nordic capitals. Helsinki offered screening to women aged 50-59 starting in 1986. The other three capitals offered screening to women aged 50-69 starting in 1989 in Stockholm, 1991 in Copenhagen, and 1996 in Oslo. Prevalence peaks in breast cancer incidence depended on the age groups covered by the screening, the length of the implementation of screening, and the extent of background opportunistic screening. No mortality reduction following the introduction of screening was visible after seven to 12 years of screening in any of the three capitals where significant effects of the screening on the breast cancer mortality had already been demonstrated by using other analytical methods for the evaluation. No visible effect on mortality reduction was expected in Oslo due to too short an observation period. The study showed that the population-based breast cancer mortality trend is too crude a measure to detect the effect of screening on breast cancer mortality during the first years after the start of a programme

  11. CONTRAST ENHANCED SPECTRAL MAMMOGRAPHY (CESM (REVIEW

    Directory of Open Access Journals (Sweden)

    N. I. Rozhkova

    2015-01-01

    Full Text Available The problem of early diagnosis of a breast cancer is extremely actual. Growth of incidence at women from 19 to 39 years increased for 34% over the last 10 years. It defines need of acceleration of development and deployment of the latest technologies of identification of the earliest symptoms of diseases. The x-ray mammography is the conducting method among of all radiological methods of diagnostics. Nevertheless a number of restrictions of method reduces its efficiency. The technologies increasing informational content of x-ray mammography – the leading method of screening – due to use of artificial contrasting and advantages of digital technologies are constantly developed. In this review it is described works, in which the authors having clinical experience of application of CESM – contrastenhanced spectral mammography on representative group of women. Positive sides and restrictions of new technology in comparison with mammography, ultrasonography and MRT are shown in this article.

  12. Retrospective observation on contribution and limitations of screening for breast cancer with mammography in Korea: detection rate of breast cancer and incidence rate of interval cancer of the breast.

    Science.gov (United States)

    Lee, Kunsei; Kim, Hyeongsu; Lee, Jung Hyun; Jeong, Hyoseon; Shin, Soon Ae; Han, Taehwa; Seo, Young Lan; Yoo, Youngbum; Nam, Sang Eun; Park, Jong Heon; Park, Yoo Mi

    2016-11-18

    The purpose of this study was to determine the benefits and limitations of screening for breast cancer using mammography. Descriptive design with follow-up was used in the study. Data from breast cancer screening and health insurance claim data were used. The study population consisted of all participants in breast cancer screening from 2009 to 2014. Crude detection rate, positive predictive value and sensitivity and specificity of breast cancer screening and, incidence rate of interval cancer of the breast were calculated. The crude detection rate of breast cancer screening per 100,000 participants increased from 126.3 in 2009 to 182.1 in 2014. The positive predictive value of breast cancer screening per 100,000 positives increased from 741.2 in 2009 to 1,367.9 in 2014. The incidence rate of interval cancer of the breast per 100,000 negatives increased from 51.7 in 2009 to 76.3 in 2014. The sensitivities of screening for breast cancer were 74.6% in 2009 and 75.1% in 2014 and the specificities were 83.1% in 2009 and 85.7% in 2014. To increase the detection rate of breast cancer by breast cancer screening using mammography, the participation rate should be higher and an environment where accurate mammography and reading can be performed and reinforcement of quality control are required. To reduce the incidence rate of interval cancer of the breast, it will be necessary to educate women after their 20s to perform self-examination of the breast once a month regardless of participation in screening for breast cancer.

  13. Effectiveness and cost-effectiveness of double reading in digital mammography screening: A systematic review and meta-analysis.

    Science.gov (United States)

    Posso, Margarita; Puig, Teresa; Carles, Misericòrdia; Rué, Montserrat; Canelo-Aybar, Carlos; Bonfill, Xavier

    2017-11-01

    Double reading is the strategy of choice for mammogram interpretation in screening programmes. It remains, however, unknown whether double reading is still the strategy of choice in the context of digital mammography. Our aim was to determine the effectiveness and cost-effectiveness of double reading versus single reading of digital mammograms in screening programmes. We performed a systematic review by searching the PubMed, Embase, and Cochrane Library databases up to April 2017. We used the QUADAS-2 (Quality Assessment of Diagnostic Accuracy Studies) tool and CHEERS (Consolidated Health Economic Evaluation Reporting Standards) checklist to assess the methodological quality of the diagnostic studies and economic evaluations, respectively. A proportion's meta-analysis approach, 95% Confidence Intervals (95% CI) and test of heterogeneity (P values) were used for pooled results. Costs are expressed US$ PPP (United States Dollar purchasing power parities). The PROSPERO ID of this Systematic Review's protocol is CRD42014013804. Of 1473 potentially relevant hits, four high-quality studies were included. The pooled cancer detection rate of double reading was 6.01 per 1000 screens (CI: 4.47‰-7.77‰), and it was 5.65 per 1000 screens (CI: 3.95‰-7.65‰) for single reading (P=0.76). The pooled proportion of false-positives of double reading was 47.03 per 1000 screens (CI: 39.13‰-55.62‰) and it was 40.60 per 1000 screens (CI: 38.58‰-42.67‰) for single reading (P=0.12). One study reported, for double reading, an ICER (Incremental Cost-Effectiveness Ratio) of 16,684 Euros (24,717 US$ PPP; 2015 value) per detected cancer. Single reading+CAD (computer-aided-detection) was cost-effective in Japan. The evidence of benefit for double reading compared to single reading for digital mammography interpretation is scarce. Double reading seems to increase operational costs, have a not significantly higher false-positive rate, and a similar cancer detection rate. Copyright

  14. Our approach for breast cancer screening using both mammography and echography, with special reference to detection of nonpalpable minute invasive cancer

    International Nuclear Information System (INIS)

    Takebe, Koji; Izumori, Ayumi; Yasumo, Naomi

    2007-01-01

    We present the results of our approach for breast cancer screening using both mammography and echography. A total of 4,632 participants underwent screening with our own combined method using mammography and echography at our clinic during a two-year period in 2005 and 2006. Recall studies were carried out in 364 women (recall rate, 79%), and breast cancer was detected in 36 women (cancer detection rate, 0.78%). When the detected cancers were classified histopathologically, 22 were invasive ductal cancers and the remaining 14 were non-invasive cancers. Of the 22 women who proved to have invasive cancers, 14 had been unaware of their tumors, which were non-palpable. If an invasive cancer is overlooked, the consequences may be more serious than if a non-invasive cancer is missed, because the former is can be potentially fatal. In order to decrease breast cancer mortality, invasive cancers must be detected when they are small. Since we were able to detect many small and non-palpable breast cancers that had not been noticed by the participants, our current breast cancer screening system appears to be more efficient for life-saving than other systems. (author)

  15. Inequity of healthcare utilization on mammography examination and Pap smear screening in Thailand: Analysis of a population-based household survey.

    Directory of Open Access Journals (Sweden)

    Sukanya Chongthawonsatid

    Full Text Available Healthcare in Thailand is not equally distributed, and not all people can equally access healthcare resources even if they are covered by health insurance. To examine factors associated with the utilization of mammography examination for breast cancer and Pap smear screening for cervical cancer, data from the national reproductive health survey conducted by the National Statistical Office of Thailand in 2009 was examined. The survey was carried out on 15,074,126 women aged 30-59 years. The results showed that the wealthier respondents had more mammograms than did the lower-income groups. The concentration index was 0.144. The data on Pap smears for cervical cancer also showed that the wealthier respondents were more likely to have had a Pap smear than their lower-income counterparts. The concentration index was 0.054. Determinants of mammography examination were education, followed by health welfare and wealth index, whereas the determinants of Pap smear screening were wealth index, followed by health welfare and education. The government should support greater education for women because education was associated with socioeconomic status and wealth. There should be an increase in the number of screening campaigns, mobile clinics, and low-cost mammograms and continued support for accessibility to mammograms, especially in rural areas and low-income communities.

  16. Breast cancer screening (breast self-examination, clinical breast exam, and mammography) in women referred to health centers in Tabriz, Iran.

    Science.gov (United States)

    Khalili, Azizeh Farshbaf; Shahnazi, Mahnaz

    2010-04-01

    Breast cancer is the most common cancer and the most common cause of death in Iranian women aged 35-55 years. Breast cancer screening comprises breast self-examination (BSE), clinical breast examination (CBE) and mammography. The study aimed to examine the performance of screening methods among women referring to health centers of Tabriz, Iran. This was a descriptive-analytical research carried out on 400 women aged 20-50 years. The samples were chosen through random multistage sampling among health centers of Tabriz then active records of women. A questionnaire and observational checklist was used to elicit socio-demographic information and performance of women towards breast cancer screening methods. Descriptive and inferential statistics (chi-square and Fisher's exact test) were used to analyze the data. Only 18.8% of women did breast self-examination, 19.1% had clinical breast examination and 3.3% had mammogram. Statistical test showed a significant relationship between performing BSE and educational level, employment, income, number of children, breastfeeding history, breastfeeding quality and family history of breast cancer. There was a significant correlation between performing CBE and history of breast tumor and also, between performing the mammography and family history of breast cancer and history of breast tumor (P pre marriage counseling periods seems necessary.

  17. Improving screen-film chest radiography

    International Nuclear Information System (INIS)

    Shaikh, N.; Baker, R.A.

    1996-01-01

    Traditionally symmetric screens and double emulsion symmetric films with medium to wide latitutde are used for radiography of the chest. Beacuse of mismatch of transmitted exposure through the chest with limited latitude of the film, most of the dense areas of the chest are underexposed. Kodak's recent innovation of a unique asymmetry screen-film system (InSight) alleviates this problem. Our phantom measurement indicates that the InSight system offers wider recording range, and the flexible grid permits more positional latitude than conventional grids. Our five-year extensive clinical experience indicates that dense anatomic structures, such as mediastinum, retrocardiac and subdiaphragmatic, are more visible in the InSight system than in the conventional symmetric system. Similarly, a substantial improvement in image quality in portable chest imaging is realized by use of flexible grids because of scatter rejection and invisible grid lines. (author)

  18. Contrast-enhanced spectral mammography in recalls from the Dutch breast cancer screening program : validation of results in a large multireader, multicase study

    NARCIS (Netherlands)

    Lalji, U C; Houben, I P L; Prevos, R; Gommers, S; van Goethem, M; Vanwetswinkel, S; Pijnappel, R; Steeman, R; Frotscher, C; Mok, W; Nelemans, P; Smidt, M L; Beets-Tan, R G; Wildberger, J E; Lobbes, M B I

    2016-01-01

    OBJECTIVES: Contrast-enhanced spectral mammography (CESM) is a promising problem-solving tool in women referred from a breast cancer screening program. We aimed to study the validity of preliminary results of CESM using a larger panel of radiologists with different levels of CESM experience.

  19. Print information to inform decisions about mammography screening participation in 16 countries with population-based programs.

    Science.gov (United States)

    Zapka, Jane G; Geller, Berta M; Bulliard, Jean-Luc; Fracheboud, Jacques; Sancho-Garnier, Helene; Ballard-Barbash, Rachel

    2006-10-01

    To profile and compare the content and presentation of written communications related to informed decision-making about mammography. Materials from 16 screening programs organized at the national or regional level were analyzed according to five major information domains suggested by the international literature. A majority of countries provided information on the program (interval, cost and quality). There was considerable variability in comprehensiveness of elements in the domains, e.g., test characteristics (false positive/negative) and pros and cons of screening. The majority noted the likelihood of recall for further tests, few commented on the risks of additional tests or finding unimportant tumors. The audit also found variation in presentation (words and pictures). Presentation of comprehensive, but balanced information on screening benefits and risks is complex and daunting. Issues such as framing effects, coupled with debate about screening efficacy are challenging to the design of effective information tools. The objective of increasing screening prevalence at the population level must be balanced with objectively presenting complete and clear information. Additional research is needed on how information (and mode of presentation) impact screening decisions. Public health officials need to articulate their objectives and review written communication according to important decision-making domains.

  20. Radiation doses and some aspects of image quality in mammography facilities in New Zealand

    International Nuclear Information System (INIS)

    Williamson, B.D.P.; Poletti, J.L.

    1990-02-01

    Until recently, mammography in New Zealand was performed largely with adapted conventional x-ray machines with tungsten anode x-ray tubes. Over the last several years these have virtually all been replaced by dedicated mammography machines with molybdenum anode x-ray tubes. To assess current trends in radiation doses to patients and central aspects of image quality, some 37 mammography x-ray machines were surveyed during 1988-89. The mean glandular dose per film for 30 and 45 mm thick breast-equivalent phantoms was determined using thermoluminescent dosimetry. Imagings of simulated microcalcifications (specks) and a contrast-detail phantom were assessed. Accuracy of calibration of the x-ray machines and quality of film processing were also tested. Details of the survey results are given. Mean glandular tissue doses per cranio-caudal films were generally well within the recommended guidelines. Mammography facilities differed in their ability to delete simulated calcification specks. Mammographic equipment was found to be generally well adjusted. Speed and contrast of film processing were found to vary widely implying that this is a major cause of the variations in dose and image quality. An annex outlines a quality assurance programme for maintenance of optimal physical image quality and control of radiation doses. 55 refs., 21 tabs., 17 figs., 2 ills

  1. Comparative study on mammographic findings between conventional mammography and digital mammography

    International Nuclear Information System (INIS)

    Gonzalez Calle, Aurelio; Saldarriaga Jaramillo, Ximena; Zapata Walliser, Luz Estela; Mejia Restrepo, Jorge Hernando; Arango Martinez, Adriana; Velez Arango, Jorge Mario

    2007-01-01

    We performed conventional-film mammograms in 180 patients between 35 and 6 years and additionally, we added 2 digital CR technique images to each patient, either craneocaudal (90 patients) or oblique (90 patients). All images were interpreted independently by four radiologists for a total of 720 evaluations, who compared film versus digital images through a 5 mega pixel monitor (soft-copy), using a score scale using the following parameters: mass visualization, detection of micro-calcifications, architectural distortion, visibility of the skin line, and image sharpness and noise. Additionally the tissue density was classified as well as the BIRADS score. The data was processed with the Teleform program and analyzed by de SPSSS program. Results: 52.6% of the micro-calcifications were equally visualized with both systems, in 13.5% of the cases they were better visualized with digital mammography. Similarly, in 50% of the cases, the skin line was better visualized with the digital CR modality. Conclusion: the sharpness of the image was also better seen with the digital CR technique in 48.2%. On the contrary, more noise was seen in digital CR images (63%). digital mammography is a diagnostic alternative that can improve mammographic findings detection and finally become a useful tool in breast cancer diagnosis

  2. An evaluation of musculoskeletal discomfort experience by radiographers performing mammography

    Energy Technology Data Exchange (ETDEWEB)

    Gale, A.G.; May, J

    1997-10-01

    The aim of this study was to establish whether breast screening radiographers experience any problems of musculoskeletal discomfort, and if so the nature and extent of these problems. The study was then further extended to investigate and determine possible occupational, causal or contributory factors, and to suggest recommendations to help alleviate any discomfort. To investigate this problem five main approaches were undertaken. These consisted of; a national survey, an observational study, the comparison of the physical measurements of the mammography units with anthropometric data, a detailed task analysis, and a body mapping study. The national survey set out to determine if the nature and frequency of such problems were higher in mammography than in other areas of radiography or in the general population. Additionally, comparisons were made with non-radiographic staff working at the same breast screening centres. Video recordings of radiographers performing breast screening were also made and posture analysis performed on these data. A detailed task analysis was conducted to identify interaction points and possible problems between the radiographer and the equipment which she is required to use. Physical measurements of the mammography units were made and compared with anthropometric measurements and guidelines. The body mapping study measured the build up of discomfort throughout the working day on several different mammography units. The results from the survey questionnaire indicated that some breast screening radiographers do experience musculoskeletal problems, and that these are different in nature and prevalence from the musculoskeletal discomfort reported by the two control groups. The prevalence of back pain reported by radiographers undertaking mammography was higher than that present in the normal population. No comparison could be made with other body areas as data regarding other types of musculoskeletal discomfort in the general population are

  3. Assessment of the usefulness of telemammography for the second reading in screening mammography

    International Nuclear Information System (INIS)

    Okuda, Itsuko; Nakajima, Yasuo; Okazaki, Hiroko; Shimamoto, Hiroshi; Okamoto, Kyoko; Kanemaki, Yoshihide; Irimoto, Masahiro

    2010-01-01

    We assessed the usefulness of telemammography by soft-copy diagnosis. A wide area network for teleradiology was set up incorporating seven institutions located in two prefectures. A total of 1053 subjects were enrolled. The first reading was performed using hard-copy images at the institution where mammography was undertaken. The second reading using hard-copy images was then performed. These images were transferred to our institution, where a second reading based on soft-copy images was performed. The result of soft-copy diagnosis were then compared with those of the hard-copy diagnosis. The diagnosis concordance rate, which was higher than category 3, was evaluated. Category 1 or 2 accounted for 956 cases at the stage of the second hard-copy diagnosis, of which category 1 or 2 accounted for 930 cases analyzed in the second soft-copy diagnosis. A category higher than 3 accounted for 97 cases at the second hard-copy diagnosis, of which a category higher than 3 accounted for 75 cases at the stage of the second soft-copy diagnosis. The κ-value for the diagnosis concordance rate was 0.751. The diagnostic concordance between hard-copy diagnosis and soft-copy diagnosis was good. Diagnostic accuracy showed no significant difference between the two. We conclude that soft-copy diagnosis by telemammography is useful, and that its application is desirable for screening mammography. (author)

  4. Can missed breast cancer be recognized by regular peer auditing on screening mammography?

    Science.gov (United States)

    Pan, Huay-Ben; Yang, Tsung-Lung; Hsu, Giu-Cheng; Chiang, Chia-Ling; Huang, Jer-Shyung; Chou, Chen-Pin; Wang, Yen-Chi; Liang, Huei-Lung; Lee, San-Kan; Chou, Yi-Hong; Wong, Kam-Fai

    2012-09-01

    This study was conducted to investigate whether detectable missed breast cancers could be distinguished from truly false negative images in a mammographic screening by a regular peer auditing. Between 2004 and 2007, a total of 311,193 free nationwide biennial mammographic screenings were performed for 50- to 69-year-old women in Taiwan. Retrospectively comparing the records in Taiwan's Cancer registry, 1283 cancers were detected (4.1 per 1000). Of the total, 176 (0.6 per 1000) initial mammographic negative assessments were reported to have cancers (128 traditional films and 48 laser-printed digital images). We selected 186 true negative films (138 traditional films and 48 laser-printed ones) as control group. These were seeded into 4815 films of 2008 images to be audited in 2009. Thirty-four auditors interpreted all the films in a single-blind, randomized, pair-control study. The performance of 34 auditors was analyzed by chi-square test. A p value of auditing should reduce the probability of missed cancers. 2012 Published by Elsevier B.V

  5. Factors related to screen-film contact in industrial radiography

    International Nuclear Information System (INIS)

    Talpe, P.

    1985-01-01

    The relative importance of screen-film contact for industrial radiography is discussed, and the results are presented of an extensive field devaluation of a new type of vacuum prepacked film-screen combination

  6. A cross sectional study on the motivators for Asian women to attend opportunistic mammography screening in a private hospital in Malaysia: the MyMammo study.

    Science.gov (United States)

    Hassan, Norhashimah; Ho, Weang Kee; Mariapun, Shivaani; Teo, Soo Hwang

    2015-06-12

    To date, because of limited budgets and lower incidence of breast cancer, the majority of Asian countries do not have population-based screening programmes, but instead offer opportunistic screening. However, there have been few studies which have assessed the motivators for women attending such programmes and the appropriateness of the programmes in terms of targeting women at risk. We conducted a prospective cross-sectional study of 1,619 women aged 40 to 74 years attending a subsidized opportunistic screening mammogram from October 2011 to October 2013 at a private hospital in Malaysia. Breast cancer risk was estimated using the Gail Model and two-step cluster analysis was used to examine the motivators of attending screening. Although Malaysia comprises 54.5% Malay, 24.5% Chinese and 7.3% Indian, the majority of women in the MyMammo Study were Chinese (70.1%) and 99.2% had a motivators. Of those with only secondary school education, their main motivators were doctors. Taken together, our results suggest the women attending opportunistic mammography screening in Asia are at low risk of breast cancer and this poses challenges to cost-effective and equitable strategies for cancer control. We propose that to improve uptake of screening mammography, awareness programmes should target both doctors and members of the public.

  7. Evaluation of the image quality criteria and study of doses in a mammography department

    International Nuclear Information System (INIS)

    Alcantara, Marcela Costa

    2009-01-01

    The mammographic image quality criteria published by European Commission were implemented in three mammography equipment of a same radiology department in a hospital of Sao Paulo city. Among the mammography equipment, two use the screen-film system and one of them uses the indirect digital system. During the data collection, it was noted the need to conduct a study about image rejection in each mammography equipment. Therefore, this study was realized and, after that, the results in each mammography equipment of image rejection and image percentage that present each quality criterion it were compared. At the same time of this studies, it was realized other study about surface entrance dose and average glandular dose. These doses it was estimated based on different methods published by different groups of researcher, for all combinations anode filter available in the equipment. To estimate the surface entrance dose following the methodology published in Avenue's' guide and the average glandular dose following the Wu' methodology, it was developed a phantom, in different thicknesses of acrylic, to simulate a breast. Finally, the image quality it was associated with the dose received by patient. The digital equipment shows better results in the evaluation of quality criteria, lower rate of image rejection and lower values of average glandular dose and surface entrance dose in all methods studied. But it is not sufficient, because is not adequate for patients with great breast. (author)

  8. Radiation hazards of X-ray mammography

    International Nuclear Information System (INIS)

    Bailar, J.C. III

    1978-01-01

    X-ray mammography delivers significant amounts of ionizing radiation to the breast, and the female breast is more susceptible to radiation carcinogenesis than any other human organ. On the other hand, breast cancer is least likely to cause serious illness and death when it is detected at a very early stage. The risks and benefits of mammography can be estimated. This paper summarizes current risk estimates, then proceeds to a comparison of risks and benefits. As for breast cancer mortality, the addition of mammography to a programme of annual breast examinations of average U.S. women is of questionable value for women under age 50 but it is probably beneficial for older women. However, the break-even point is closely related to the average radiation exposure of breast tissue, and would be earlier in a few centres now using optimum techniques and equipment. For women with below-average risks of breast cancer, the age would be higher, and for a few women with a high probability of developing breast cancer it would be lower. Breast cancer screening programmes have been improved significantly since criticisms were first publicized in mid-1975. Partial improvements include reduction in radiation exposure (at least in some centres), guidelines from the National Cancer Institute (NCI) and the American Cancer Society (ACS) for restricting the screening of women under age 50, and changes in the patient consent form signed by participants in the NCI-ACS programme. Professional and public awareness of the need to balance the benefits of screening with its risks and costs has rapidly and markedly increased. Future improvements should further define the optimum design and application of breast cancer screening programmes

  9. Dose to population as a metric in the design of optimised exposure control in digital mammography

    International Nuclear Information System (INIS)

    Klausz, R.; Shramchenko, N.

    2005-01-01

    This paper describes a methods for automatic optimisation of parameter (AOP) in digital mammography systems. Using a model of the image chain, contrast to noise ratio (CNR) and average glandular dose (AGD) are computed for possible X-ray parameters and breast types. The optimisation process consists of the determination of the operating points providing the lowest possible AGD for each CNR level and breast type. The proposed metric for the dose used in the design of an AOP mode is the resulting dose to the population, computed by averaging the AGD values over the distribution of breast types in the population. This method has been applied to the automatic exposure control of new digital mammography equipment. Breast thickness and composition are estimated from a low dose pre-exposure and used to index tables containing sets of optimised operating points. The resulting average dose to the population ranges from a level comparable to state-of-the-art screen/film mammography to a reduction by a factor of two. Using this method, both CNR and dose are kept under control for all breast types, taking into consideration both individual and collective risk. (authors)

  10. A comparison of two different T-grain films in rare-earth screens with a standard film-screen combination for intravenous pyelography and bone examinations

    International Nuclear Information System (INIS)

    Logan, H.; Daly, L.; Masterson, J.

    1989-01-01

    T-grain film is claimed to give significantly improved image quality, allowing use of faster screens without loss of quality, thus reducing radiation dose. We tested this claim for two systems. In each case comparison was made with our usual screen-film combination, Agfa Curix RP1 film with Kodak Xomatic Regular screens (a nominally 200 speed system). The systems tested were Kodak TMatG in Kodak Lanex Medium screens (300 speed) and Agfa STG in Kodak Lanex Regular screens (400 speed). The Agfa STG-Lanex Regular system performed less well than the standard system for intravenous pyelograms (IVPs), bones and soft-tissue detail. Its speed advantage was not apparent below 70 kV. The Kodak TMatG-Lanex Medium system was better than the standard system for IVPs but not as good for bones. It gave virtually no speed advantage below 90 kV. Kodak T-grain film in a medium-speed, rare-earth screen was found to be better than the standard system for IVPs. Agfa T-grain film in a fast rare-earth screen was unsatisfactory for IVPs. Neither combination was as good as the standard system for bones. (author)

  11. Tomosynthesis as a screening tool for breast cancer: A systematic review

    International Nuclear Information System (INIS)

    Coop, P.; Cowling, C.; Lawson, C.

    2016-01-01

    Background: Mammography is an important screening tool for reducing breast cancer mortality. Digital breast tomosynthesis (DBT) can potentially be integrated with mammography to aid in cancer detection. Method: Using the PRISMA guidelines, a systematic review of current literature was conducted to identify issues relating to the use of tomosynthesis as a screening tool together with mammography. Findings: Using tomosynthesis with digital mammography (DM) increases breast cancer detection, reduces recall rates and increases the positive predictive value of those cases recalled. Invasive cancer detection is significantly improved in tomosynthesis compared to mammography, and has improved success for women with heterogeneous or extremely dense breasts. Conclusion: Tomosynthesis reduces some limitations of mammography at the time of screening that until recently were most often addressed by ultrasound at later work-up. Tomosynthesis can potentially be adopted alongside mammography as a screening tool. - Highlights: • Using tomosynthesis with digital mammography increases breast cancer detection. • Tomosynthesis has improved detection for women with extremely dense breasts. • Tomosynthesis reduces the need for ultrasound to address mammography limitations. • When Tomosynthesis is combined with mammography, recall rates are reduced.

  12. Mammography discomfort: a holistic perspective derived from women's experiences

    International Nuclear Information System (INIS)

    Poulos, Ann; Llewellyn, Gwynnyth

    2005-01-01

    Purpose: Mammography discomfort has the potential to deter women from attending for regular breast screening. Previous studies have focussed on the pain/discomfort of the mammography procedure itself. The purpose of this study was to consider discomfort from a holistic perspective of the mammography experience derived from the women themselves. Methods: Qualitative research methods were employed. Using theoretical sampling, 12 women who had recently experienced mammography were interviewed. The interview questions aimed to explore the experience of women attending for a mammogram from arrival to departure and beyond in order to identify aspects which potentially increase discomfort. Data analysis involved coding and categorisation and identification of key concepts and their relationships. Results: A conceptual framework was developed that demonstrates the contributors to mammography discomfort and the relationships between these as identified by the women. Conclusions: The conceptual framework has important implications for clinical practice and future research

  13. Signal detectability of mammography depends on film-screen system and luminance of view box

    International Nuclear Information System (INIS)

    Maeda, Fumie; Ogura, Akio; Miyai, Akira

    2003-01-01

    High-density film and the high-luminance view-box system are being recommended for mammograms owing to the improved detection of masses. However, this system causes an increase in radiation. Therefore, the purpose of this study was to assess whether the detection of masses would improve using the normal-luminance view box and normal-density film with different types of contrast systems. Low-contrast detection using receiver operating characteristic (ROC) analysis and high-contrast detection using an American College of Radiology (ACR) phantom were evaluated for the following systems: high-density film and high-luminance view box, normal-density film and normal-luminance view box, and normal-density film with wide latitude and normal-luminance view box. The results showed no significant variation in the detectability of the system with high-density film and high-luminance view box and the normal-density film with wide latitude and normal-luminance view box. However, in terms of low-contrast visibility, the system using normal-density film and normal-luminance view box was significantly reduced in comparison with the others. Therefore, the system with normal-density film with wide latitude and the normal-luminance view box is recommended because of reduced radiation dose. (author)

  14. Optimal screening mammography reading volumes; evidence from real life in the East Midlands region of the NHS Breast Screening Programme

    International Nuclear Information System (INIS)

    Cornford, E.; Reed, J.; Murphy, A.; Bennett, R.; Evans, A.

    2011-01-01

    Aim: To assess real-life reader performance as a function of both volume of mammograms read and reading experience in a multicentre cohort. Materials and methods: Thirty-seven film readers from the East Midlands Breast Screening Programme had 3 years of consecutive screen reading results available for comparison. Markers of screening performance as the first film reader [cancer detection rates, small cancer detection rates, recall rates, positive predictive value of recall (PPV), and missed cancers] were compared with both volume of films read and years of film reading experience. For reading volume, readers were categorized according to film reading volume over the 3 year period: <15,000 (i.e., on average less than the recommended 5000/year); 15-<20,000; 20-<25,000; and ≥25,000. For years of experience, readers were categorized into the following groups: <5 years, 5-<10 years, 10-<15 years, and 15-<20 years. Results: There was no evidence to suggest a relationship between years of film reading experience and film-reading performance. For reading volume, there was a significant difference in the distribution of cancer-detection rate between the four groups (p = 0.01); however, there was no difference in small cancer-detection rates, missed cancers or PPV. The median cancer detection rate in the high-volume group (≥25,000 mammograms/3 years) was significantly lower than the other groups combined (6.9 per 1000 women screened versus 7.9 per 1000 women screened). The lowest median recall rate was also in the high-volume group, whilst those readers not meeting the NHSBSP minimum requirement had the highest median recall rate; however, there was borderline evidence to suggest a difference in the distribution of recall rates between the four groups. Conclusion: The data from the East Midlands do not provide any evidence for reducing the threshold volume of 5000 cases /year. However, there appears to be an upper limit above which reader performance deteriorates in

  15. Evaluation of glandular dose in conventional and digital mammography systems

    International Nuclear Information System (INIS)

    Coutinho, Celia Maria Campos

    2009-01-01

    A survey was conducted to estimate the average glandular dose (D g ) for patients undergoing mammography and to report the distribution of incident air kerma (K i ), patient age, compressed breast thickness and glandular tissue content. From 1183 cranio caudal mammograms clinical data were collected and doses were measured. The survey data included mammograms from six mammography equipment: two screen/film units (SFM), two computed radiography units (CR) and two full-field digital (DR). Mean value for patient age and compressed breast thickness were 57 +-12 y and 5.4 +-1.4 cm, respectively. To investigate the importance of technical characteristics of three different mammography systems and breast glandularity, K i and D g were measured for individual breast of 392 patients from the original sample with compressed breast thickness in the range of 5.5 cm to 6.5 cm using tissue-equivalent phantoms of different glandularities manufactured in this study to mimic both the attenuation and the density of breast tissues. Mean K i value was 10.0 +-3.6 mGy for SFM systems, 12.0 +-3.6 mGy for CR systems and 4.9 +-1.3 mGy for DR systems. Mean D g value was 1.4 +-0.5 mGy for S/F systems, 1.7 +-0.5 mGy for CR systems and 0.9 +-0.2 mGy for D R systems. Statistical analysis for differences in mean values of K i and D g between mammography systems showed significant effect of their technical characteristics (p i and D g , it was observed statistically significant differences between the group of patients with 0 to 50% glandularity and the group of patients with 50 to 100% glandularity. (author)

  16. Current status of mammography

    International Nuclear Information System (INIS)

    Crymes, J.E.

    1979-01-01

    Great progress has been made in recent years in the diagnosis and treatment of breast cancer; however, breast cancer continues to be the most common and lethal cancer in women today. Early diagnosis is essential in order for treatmet to be given before the tumor spreads beyond the breast. The radiation risks of mammography have been greatly reduced with the use of newer low-dose techniques, and the benefits of mammography have increased because of a better understanding of the natural history of breast cancer, as well as improved methods of treatment. Radiologists must continue to take an active role in the early diagnosis of breast cancer. Continued research is needed in order to improve screening methods and to develop newer, noninvasive techniques

  17. Contrast-enhanced spectral mammography in recalls from the Dutch breast cancer screening program : validation of results in a large multireader, multicase study

    OpenAIRE

    Lalji, U C; Houben, I P L; Prevos, R; Gommers, S; van Goethem, M; Vanwetswinkel, S; Pijnappel, R; Steeman, R; Frotscher, C; Mok, W; Nelemans, P; Smidt, M L; Beets-Tan, R G; Wildberger, J E; Lobbes, M B I

    2016-01-01

    OBJECTIVES: Contrast-enhanced spectral mammography (CESM) is a promising problem-solving tool in women referred from a breast cancer screening program. We aimed to study the validity of preliminary results of CESM using a larger panel of radiologists with different levels of CESM experience. METHODS: All women referred from the Dutch breast cancer screening program were eligible for CESM. 199 consecutive cases were viewed by ten radiologists. Four had extensive CESM experience, three had no C...

  18. An evaluation of musculoskeletal discomfort experience by radiographers performing mammography

    International Nuclear Information System (INIS)

    Gale, A.G.; May, J.

    1997-01-01

    The aim of this study was to establish whether breast screening radiographers experience any problems of musculoskeletal discomfort, and if so the nature and extent of these problems. The study was then further extended to investigate and determine possible occupational, causal or contributory factors, and to suggest recommendations to help alleviate any discomfort. To investigate this problem five main approaches were undertaken. These consisted of; a national survey, an observational study, the comparison of the physical measurements of the mammography units with anthropometric data, a detailed task analysis, and a body mapping study. The national survey set out to determine if the nature and frequency of such problems were higher in mammography than in other areas of radiography or in the general population. Additionally, comparisons were made with non-radiographic staff working at the same breast screening centres. Video recordings of radiographers performing breast screening were also made and posture analysis performed on these data. A detailed task analysis was conducted to identify interaction points and possible problems between the radiographer and the equipment which she is required to use. Physical measurements of the mammography units were made and compared with anthropometric measurements and guidelines. The body mapping study measured the build up of discomfort throughout the working day on several different mammography units. The results from the survey questionnaire indicated that some breast screening radiographers do experience musculoskeletal problems, and that these are different in nature and prevalence from the musculoskeletal discomfort reported by the two control groups. The prevalence of back pain reported by radiographers undertaking mammography was higher than that present in the normal population. No comparison could be made with other body areas as data regarding other types of musculoskeletal discomfort in the general population are

  19. Phosphor plate mammography: contrast studies and clinical experience

    International Nuclear Information System (INIS)

    Chang, C.H.J.; Martin, N.L.; Templeton, A.W.; Cook, L.T.; Harrison, L.A.; McFadden, M.A.; Dwyer, S.J. III; Spicer, J.; Crystal, J.M.

    1992-01-01

    Mammography and accurate microcalcification detection require very good spatial resolution. We have compared the diagnostic capabilities of reduced-exposure, third-generation, 5 cycles/mm computed radiography (CR) phosphor plates with conventional screen-film in 67 patients. No difference in diagnostic accuracy was detected. The digital characteristics of storage phosphor plates erabled us to study the relationship between contrast and spatial resolution. We developed a computer program to identify a single 100 μm pixel in a digital image and assign various gray levels to that pixel. Using this model, we determined that, for our 5 cycles/mm CR system, the imaged contrast of a 100 μm object was 62% of the original contrast. Current 5 cycles/mm phosphor plate systems cannot adequately detect microcalcifications that approximate 100 μm or smaller unless a magnification technique is used. (orig.)

  20. Abnormality Detection in Mammography using Deep Convolutional Neural Networks

    OpenAIRE

    Xi, Pengcheng; Shu, Chang; Goubran, Rafik

    2018-01-01

    Breast cancer is the most common cancer in women worldwide. The most common screening technology is mammography. To reduce the cost and workload of radiologists, we propose a computer aided detection approach for classifying and localizing calcifications and masses in mammogram images. To improve on conventional approaches, we apply deep convolutional neural networks (CNN) for automatic feature learning and classifier building. In computer-aided mammography, deep CNN classifiers cannot be tra...

  1. Mammography. [Patent750AIX-08)293916

    Energy Technology Data Exchange (ETDEWEB)

    1975-04-01

    This patent reveals a method and instrument for the detection and registration of breast cancer with the aid of X-radiation, i.e. mammography. The breast is irradiated with soft X-rays whereby the radiation beam is scanned with a moving 'stripform' screen and whereby the picture from the 'stripform' screen is recorded by a television camera that moves simultaneously with the strip. The image is then projected on a monitor.

  2. With the Advent of Tomosynthesis in the Workup of Mammographic Abnormality, is Spot Compression Mammography Now Obsolete? An Initial Clinical Experience.

    Science.gov (United States)

    Ni Mhuircheartaigh, Neasa; Coffey, Louise; Fleming, Hannah; O' Doherty, Ann; McNally, Sorcha

    2017-09-01

    To determine if the routine use of spot compression mammography is now obsolete in the assessment of screen detected masses, asymmetries and architectural distortion since the availability of digital breast tomosynthesis. We introduced breast tomosynthesis in the workup of screen detected abnormalities in our screening center in January 2015. During an initial learning period with tomosynthesis standard spot compression views were also performed. Three consultant breast radiologists retrospectively reviewed all screening mammograms recalled for assessment over the first 6-month period. We assessed retrospectively whether there was any additional diagnostic information obtained from spot compression views not already apparent on tomography. All cases were also reviewed for any additional lesions detected by tomosynthesis, not detected on routine 2-view screening mammography. 548 women screened with standard 2-view digital screening mammography were recalled for assessment in the selected period and a total of 565 lesions were assessed. 341 lesions were assessed by both tomosynthesis and routine spot compression mammography. The spot compression view was considered more helpful than tomosynthesis in only one patient. This was because the breast was inadequately positioned for tomosynthesis and the area in question was not adequately imaged. Apart from this technical error there was no asymmetry, distortion or mass where spot compression provided more diagnostic information than tomosynthesis alone. We detected three additional cancers on tomosynthesis, not detected by routine screening mammography. From our initial experience with tomosynthesis we conclude that spot compression mammography is now obsolete in the assessment of screen detected masses, asymmetries and distortions where tomosynthesis is available. © 2017 Wiley Periodicals, Inc.

  3. Richtlijn 'screening en diagnostiek van het mammacarcinoom' (herziening).

    NARCIS (Netherlands)

    Zonderland, H.M.; Tuut, M.K.; den Heeten, G.J.; Asperen, C.J.; de Bock, G.H.; Rutqers, E.J.; Westenend, P.J.; Smit, G.M.; Benraadt, J.

    2008-01-01

    Revised practice guideline 'Screening and diagnosis of breast cancer' The evidence-based revision of the practice guideline 'Screening and diagnosis of breast cancer' was necessitated by new insights, for instance on the cost-effectiveness of screening modalities other than mammography. Mammography

  4. Evaluation of average glandular dose in digital and conventional systems of the mammography

    International Nuclear Information System (INIS)

    Xavier, Aline C.S.; Barros, Vinicius S.M.; Khoury, Hellen J.

    2014-01-01

    Mammography is currently the most effective method of diagnosis and detection of breast pathologies. The main interest in this kid of exam comes from the high incidence rate of breast cancer and necessity of high quality images for accurate diagnosis. Digital mammography systems have several advantages compared to conventional systems, however the use of digital imaging systems is not always integrated to an image acquisition protocol. Therefore, it is questionable if digital systems truly reduce the dose received by the patient, because many times is introduced in the clinics without optimization of the image acquisition protocols. The aim of this study is to estimate the value of incident air Kerma and average glandular dose (AGD) in patients undergoing conventional and digital mammography systems in Recife. This study was conducted with 650 patients in three hospitals. The value of incident air Kerma was estimated from the measurement of the yield of equipment and irradiation parameters used for each patient. From these results and using the methodology proposed by Dance et al. the value of the average glandular dose was calculated. The results obtained show that the lowest value of AGD was found with conventional screen-film system, indicating that the parameters for image acquisition with digital systems are not optimized. It was also observed that the institutions with digital systems use lower breast compression values than the conventional. (author)

  5. Cost-effectiveness analysis of mammography and clinical breast examination strategies

    Science.gov (United States)

    Ahern, Charlotte Hsieh; Shen, Yu

    2009-01-01

    Purpose Breast cancer screening by mammography and clinical breast exam are commonly used for early tumor detection. Previous cost-effectiveness studies considered mammography alone or did not account for all relevant costs. In this study, we assessed the cost-effectiveness of screening schedules recommended by three major cancer organizations and compared them with alternative strategies. We considered costs of screening examinations, subsequent work-up, biopsy, and treatment interventions after diagnosis. Methods We used a microsimulation model to generate women’s life histories, and assessed screening and treatment impacts on survival. Using statistical models, we accounted for age-specific incidence, preclinical disease duration, and age-specific sensitivity and specificity for each screening modality. The outcomes of interest were quality-adjusted life years (QALYs) saved and total costs with a 3% annual discount rate. Incremental cost-effectiveness ratios were used to compare strategies. Sensitivity analyses were performed by varying some of the assumptions. Results Compared to guidelines from the National Cancer Institute and the U.S. Preventive Services Task Force, alternative strategies were more efficient. Mammography and clinical breast exam in alternating years from ages 40 to 79 was a cost-effective alternative compared to the guidelines, costing $35,500 per QALY saved compared with no screening. The American Cancer Society guideline was the most effective and the most expensive, costing over $680,000 for an added QALY compared to the above alternative. Conclusion Screening strategies with lower costs and benefits comparable to those currently recommended should be considered for implementation in practice and for future guidelines. PMID:19258473

  6. Detection of pulmonary nodules. Improvement by new screen-film systems?

    International Nuclear Information System (INIS)

    Lehmann, K.J.; Himmighoefer, U.

    1994-01-01

    In addition to digital radiography and AMBER, the development of asymmetric screen-film systems is another attempt to optimize chest radiography. Due to reduced contrast in the parenchyma, the former asymmetric screen-film systems did not show sufficient image quality. Three new asymmetric systems with completely different composition are available now. In-Sight VHC (Kodak), High Light GUV (3M) and Opthos D (Agfa) were compared to standard chest films using densitometric curves, a chest phantom for high and low contrast detectability, a nodule detection phantom and patient studies. The sensitivity of nodule detection in the mediastinum has been 41-48% for L-films and 58-65% for the asymmetric screen-film systems. No differences could be demonstrated for nodule detection in the lung field. Contrast in the parenchyma is equivalent to L-films. There is no loss of diagnostic information in the lung field. Differences between the asymmetric systems concern speed, dynamic range and granularity. If AMBER and digital radiography are not available, new asymmetric screen-film systems can improve nodule detection without further investment costs. (orig.) [de

  7. [High-contrast resolution of film-screen systems in oral and maxillofacial radiology].

    Science.gov (United States)

    Kaeppler, G; Reinert, S

    2007-11-01

    The aim was to determine differences in high-contrast resolution of film-screen systems used in dental panoramic and cephalometric radiography by calculating the modulation transfer function (MTF). The radiographs used to determine the MTF should be taken by the same x-ray units as those used for patient radiographs. The MTF was determined using a lead grid and according to DIN 6867-2 for 11 film-screen systems (speed 250, speed class 200 and 400) used in dental radiographic diagnostics. The optical density was measured using a microdensitometer developed by PTB. With 10% of the modulation transfer factor, newly developed film-screen systems (speed class 200 and 400) demonstrated a resolution of 4.9 to 6 line pairs per mm (panoramic radiography). In cephalometric radiography a film-screen system (speed class 400 and green-sensitive film) had a resolution of 4.2 line pairs per mm and surpassed two film-screen systems (speed class 400, resolution of 3 line pairs per mm, blue-sensitive films). The relevance of this study is underlined by the diagnostic reference doses defined in the German X-ray Ordinance (RöV) which are also intended for dentistry. Film-screen systems (speed 250, speed class 200) previously used in dental panoramic and cephalometric radiography can be replaced by newly developed film-screen systems (speed class 400). In dental radiography dose reductions are possible with film-screen systems (speed class 400) without impairing diagnostic accuracy. The introduction of newly developed film-screen systems (speed class 400) requires lower milliampere-seconds and therefore an adjustment of the x-ray units to lower milliampere settings.

  8. Digital mammography and their developments; Digitale Mammografie und ihre Weiterentwicklung

    Energy Technology Data Exchange (ETDEWEB)

    Wienbeck, Susanne [Universitaetsmedizin Goettingen (Germany). Inst. fuer Diagnostische und Interventionelle Radiologie; Fischer, Uwe [Diagnostisches Brustzentrum Goettingen (Germany)

    2015-09-15

    At the present time digital mammography is a satisfactory breast diagnostic imaging in clinical as well as screening mammography in defined age groups. Nevertheless it shows beside the application of ionizing radiation in women with dense breasts limitations in the detection of non calcification breast cancers. Tomosynthesis, digital contrast-enhanced mammography and breast-CT with or without contrast media lead to better results. Especially the application of contrast media for the visualisation of the tumor angiogenesis is invariably superior to all other non-contrast imaging modalities. However, the excellent results of breast MRI will be probably accessible with none of the new procedures.

  9. Radiographer involvement in mammography image interpretation: A survey of United Kingdom practice

    International Nuclear Information System (INIS)

    Culpan, A.M.

    2016-01-01

    Breast cancer is most often diagnosed using x-ray mammography. Traditionally mammography images have been interpreted and reported by medically qualified practitioners – radiologists. Due to radiologist workforce shortages in recent years some non-medical practitioners, radiographers, now interpret and report mammography images. The aims of this survey were to describe the characteristics and practices of radiographers who interpret and report mammography images in NHS hospitals in the UK, and in particular to establish the extent of their practice beyond low-risk asymptomatic screening cases. This service evaluation demonstrated that UK radiographers are interpreting and reporting images across the full spectrum of clinical indications for mammography including: low-risk population screening, symptomatic, annual surveillance, family history and biopsy/surgical cases. The survey revealed that radiographers are involved in a diverse range of single and double reading practices where responsibility for diagnostic decision making is shared or transferred between radiologists and/or other radiographers. Comparative analysis of sub-group data suggested that there might be differences in the characteristics and practices of radiographers who interpret only low-risk screening mammograms and those who interpret and report a wider range of cases. The findings of this survey provide a platform for further research to investigate how and why the roles and responsibilities of radiographers who interpret and report mammograms vary between organisations, between practitioners and across different examinations. Further research is also needed to explore the implications of variation in practice for patients, practitioners and service providers. - Highlights: • UK radiographers interpret mammograms across the full spectrum of clinical indications. • UK radiographers are involved in a wide range of single/double mammography reading practices. • Characteristics required for

  10. Current perspectives on indications and limitations of mammography

    International Nuclear Information System (INIS)

    Pope, T.L. Jr.

    1983-01-01

    Women have a 7 percent natural lifetime risk of developing breast cancer, which is the leading cause of death in women aged 40 to 50 years. Most data suggest that the earlier the disease is diagnosed, the better the chance for cure. Women with ''minimal breast cancer'' have an actuarial 20-year survival rate of 93.2 percent. The majority of these breast cancers are diagnosed by mammography. The radiation doses from this technique have been dramatically decreased over the last ten years to about 0.1 to 0.6 rads per study. The two largest breast cancer screening studies, the Health Insurance Plan of Greater New York and the Breast Cancer Detection Demonstration Project, have shown conclusively that women over 50 years old can benefit from annual mammography and that certain groups can benefit from mammography at close intervals before the age of 50 years. This article describes the development of mammography and outlines current perspectives on its indications and limitations

  11. The evolving role of new imaging methods in breast screening.

    Science.gov (United States)

    Houssami, Nehmat; Ciatto, Stefano

    2011-09-01

    The potential to avert breast cancer deaths through screening means that efforts continue to identify methods which may enhance early detection. While the role of most new imaging technologies remains in adjunct screening or in the work-up of mammography-detected abnormalities, some of the new breast imaging tests (such as MRI) have roles in screening groups of women defined by increased cancer risk. This paper highlights the evidence and the current role of new breast imaging technologies in screening, focusing on those that have broader application in population screening, including digital mammography, breast ultrasound in women with dense breasts, and computer-aided detection. It highlights that evidence on new imaging in screening comes mostly from non-randomised studies that have quantified test detection capability as adjunct to mammography, or have compared measures of screening performance for new technologies with that of conventional mammography. Two RCTs have provided high-quality evidence on the equivalence of digital and conventional mammography and on outcomes of screen-reading complemented by CAD. Many of these imaging technologies enhance cancer detection but also increase recall and false positives in screening. Copyright © 2011 Elsevier Inc. All rights reserved.

  12. The Effect of Lead Intensification Screens on Film: Modeling and Experiment

    International Nuclear Information System (INIS)

    Wendt, S.; Gray, J.; Zhou, C.

    2004-01-01

    A physics-based, intensification screen model, using lead as an example, has been developed. Comparisons to experimental results are shown. The dominant effect in producing the intensification is from photoelectrons ejected from a 24 - 40 micron layer of lead near the film with Compton electrons and the lead fluorescence x-rays contributing less than 10% to the intensification for settings below 300 kvp. The thickness of lead screen for optimal intensification is between 15 and 70 microns depending upon the energy of the photon. This is less than the traditional practice of a 130 microns front screen and 260 microns back screen. The model computes the intensifying effect of lead screens placed in front or in back of a sheet of radiographic film and accounts for the strong energy dependent effects contributing to the intensification. The lead screen model is independent of film type, so the user can select any type of film and any combination of lead thickness for the front and back screens. The model uses energy dependent x-ray photon absorption cross-sections to compute the production of electrons in the lead. A Monte Carlo calculation was used to determine energy dependent electron penetration in the lead and the film. The model calculates electron attenuation in the film emulsion, the film substrate and both front and back lead screens and determines the intensification effect as a function of the energy deposited in the film. For model validation, lead screen intensification was studied with x-ray generator settings ranging from 75 to 320 kvp and using various thicknesses of aluminum and iron attenuators to filter the x-ray beam. A high precision motion control system coupled with a high purity germanium detector was used to study the energy spectra

  13. The efficacy of using computer-aided detection (CAD) for detection of breast cancer in mammography screening: a systematic review.

    Science.gov (United States)

    Henriksen, Emilie L; Carlsen, Jonathan F; Vejborg, Ilse Mm; Nielsen, Michael B; Lauridsen, Carsten A

    2018-01-01

    Background Early detection of breast cancer (BC) is crucial in lowering the mortality. Purpose To present an overview of studies concerning computer-aided detection (CAD) in screening mammography for early detection of BC and compare diagnostic accuracy and recall rates (RR) of single reading (SR) with SR + CAD and double reading (DR) with SR + CAD. Material and Methods PRISMA guidelines were used as a review protocol. Articles on clinical trials concerning CAD for detection of BC in a screening population were included. The literature search resulted in 1522 records. A total of 1491 records were excluded by abstract and 18 were excluded by full text reading. A total of 13 articles were included. Results All but two studies from the SR vs. SR + CAD group showed an increased sensitivity and/or cancer detection rate (CDR) when adding CAD. The DR vs. SR + CAD group showed no significant differences in sensitivity and CDR. Adding CAD to SR increased the RR and decreased the specificity in all but one study. For the DR vs. SR + CAD group only one study reported a significant difference in RR. Conclusion All but two studies showed an increase in RR, sensitivity and CDR when adding CAD to SR. Compared to DR no statistically significant differences in sensitivity or CDR were reported. Additional studies based on organized population-based screening programs, with longer follow-up time, high-volume readers, and digital mammography are needed to evaluate the efficacy of CAD.

  14. The research on noise equivalent quanta and detective quantum efficiency of screen-film system

    International Nuclear Information System (INIS)

    Xie Jingdong; Wang Changyuan; Yuan Yude; Zhang Menglong; Wang Jian; Zheng Hao; Sun Yong

    2002-01-01

    Objective: To examine the noise equivalent quanta (NEQ) and detective quantum efficiency (DQE) of screen-film system. Methods: Green 400 screen-Kodak film and CaWO 4 screen-Fuji film were used in the study. The characteristic curves were obtained by distance method. The square wave technique was employed to determine the modulation transfer function (MTF). The Wiener spectrum (WS) was determined by Fourier analysis on uniformly exposed films. The NEQ and DQE were calculated from the characteristic curve slope, MTF, and WS measurements. Results: (1) The NEQ value of Green 400 screen-Kodak film system was 1.48 x 10 6 mm -2 when the spatial frequency was 0.6 cycles/mm, and it was 0.65 times larger than that of CaWO 4 screen-Fuji film system; The NEQ value of Green 400 screen-Kodak film system was 0.329 x 10 4 mm -2 when the spatial frequency was 4.0 cycles/mm, and it was 1.55 times larger than that of CaWO 4 screen-Fuji film system. (2) The DQE value of Green 400 screen-Kodak film system was 0.224 when the spatial frequency was 0.6 cycles/mm, and it was 1.6 times larger than that of CaWO 4 screen-Fuji film system; The DQE value of Green 400 screen-Kodak film system was 0.052 when the spatial frequency was 4.0 cycles/mm, and it was 3.7 times larger than that of CaWO 4 screen-Fuji film system. Conclusion: The Green 400 Screen-Kodak film system has superior NEQ when the spatial frequency was more than 3.0 cycles/mm and has superior DQE among the total spatial frequency in comparison with CaWO 4 screen-Fuji film system

  15. Ultrasound as a secondary screening tool in mammographically dense breasts

    International Nuclear Information System (INIS)

    Griggs, Kylie

    2006-01-01

    It is well known that breast screening is a part of our society and is designed to reduce the mortality and morbidity from breast cancer. Mammography is the imaging modality of choice in a breast-screening environment. Both the detection rate of mammography in a screening environment and the sensitivity of mammography in symptomatic women are known to be greater than that of ultrasound. However, after a review of literature both of these are said to increase when the two imaging modalities are combined. This paper will present that mammography has limitation

  16. Postmortem validation of breast density using dual-energy mammography

    OpenAIRE

    Molloi, Sabee; Ducote, Justin L.; Ding, Huanjun; Feig, Stephen A.

    2014-01-01

    Purpose: Mammographic density has been shown to be an indicator of breast cancer risk and also reduces the sensitivity of screening mammography. Currently, there is no accepted standard for measuring breast density. Dual energy mammography has been proposed as a technique for accurate measurement of breast density. The purpose of this study is to validate its accuracy in postmortem breasts and compare it with other existing techniques. Methods: Forty postmortem breasts were imaged using a dua...

  17. Physical image quality of computed radiography in mammography system

    International Nuclear Information System (INIS)

    Norriza Mohd Isa; Muhammad Jamal Isa; Wan Muhamad Saridan Wan Hassan; Fatimah Othman

    2013-01-01

    Full-text: Mammography is a screening procedure that mostly used for early detection of breast cancer. In digital imaging system, Computed Radiography is a cost-effective technology that applied indirect conversion detector. The paper presents physical image quality parameter measurements namely modulation transfer function (MTF), normalized noise power spectrum (NNPS) and detective quantum efficiency (DQE) of Computed Radiography in mammography system. MTF was calculated from two different orientations of slanted images of an edge test device and NNPS was estimated using flat-field image. Both images were acquired using a standard mammography beam quality. DQE was determined by applying the MTF and NNPS values into our developed software program. Both orientations have similar DQE characteristics. (author)

  18. Ditching the Disc: The Effects of Cloud-Based Image Sharing on Department Efficiency and Report Turnaround Times in Mammography.

    Science.gov (United States)

    Morgan, Matthew B; Young, Elizabeth; Harada, Scott; Winkler, Nicole; Riegert, Joanna; Jones, Tony; Hu, Nan; Stein, Matthew

    2017-12-01

    In screening mammography, accessing prior examination images is crucial for accurate diagnosis and avoiding false-positives. When women visit multiple institutions for their screens, these "outside" examinations must be retrieved for comparison. Traditionally, prior images are obtained by faxing requests to other institutions and waiting for standard mail (film or CD-ROM), which can greatly delay report turnaround times. Recently, advancements in cloud-based image transfer technology have opened up more efficient options for examination transfer between institutions. The objective of this study was to evaluate the effect of cloud-based image transfer on mammography department workflow, time required to obtain prior images, and report turnaround times. Sixty screening examinations requiring prior images were placed into two groups (30 each). The control group used the standard institutional protocol for requesting prior images: faxing requests and waiting for mailed examinations. The experimental group used a cloud-based transfer for both requesting and receiving examinations. The mean number of days between examination request and examination receipt was measured for both groups and compared. The mean number of days from examination request to receipt was 6.08 days (SD 3.50) in the control group compared with 3.16 days (SD 3.95) in the experimental group. Using a cloud-based image transfer to obtain prior mammograms resulted in an average reduction of 2.92 days (P = .0361; 95% confidence interval 0.20-5.65) between examination request and receipt. This improvement in system efficiency is relevant for interpreting radiologists working to improve reporting times and for patients anxious to receive their mammography results. Copyright © 2017 American College of Radiology. Published by Elsevier Inc. All rights reserved.

  19. First epidemiological analysis of breast cancer incidence and tumor characteristics after implementation of population-based digital mammography screening

    International Nuclear Information System (INIS)

    Weigel, Stefanie; Heindel, Walter; Batzler, W.U.; Decker, T.; Hense, H.W.

    2009-01-01

    Purpose: to epidemiologically evaluate the impact of digital mammography screening on incidence rates and tumor characteristics for breast cancer. Materials and methods: the first German digital screening units in the clinical routine were evaluated during the implementation period by using data from the cancer registry to compare the incidence rate of breast cancers and prognostic characteristics. 74% of women aged 50-69 within the region of Muenster/Coesfeld/Warendorf were invited between 10/2005 and 12/2007 for initial screening; 55% participated (n = 35961). Results: in 2002-2004 the average breast cancer incidence rate (per 100000) was 297.9. During the implementation of screening, the rate rose to 532.9 in 2007. Of the 349 cancers detected with screening, 76% (265/349) were invasive compared to 90% (546/608) of cases not detected with screening during the same period. 37% (97/265) of cancers detected in the screening program had a diameter of ≤ 10 mm and 75% (198/265) were node-negative compared to 15% (79/546) and 64% (322/503), respectively, in cancers detected outside the screening program. The distribution of invasive tumor size (pT categories) and the nodal status differed with statistical significance between cancers detected in and outside the program (p = 0.005 and p = 0.004, respectively). (orig.)

  20. Breast cancer screening (BCS) chart: a basic and preliminary model for making screening mammography more productive and efficient.

    Science.gov (United States)

    Poorolajal, Jalal; Akbari, Mohammad Esmaeil; Ziaee, Fatane; Karami, Manoochehr; Ghoncheh, Mahshid

    2017-05-15

    The breast cancer screening (BCS) chart is suggested as a basic and preliminary tool to improve efficiency of screening mammography. We conducted this case-control study in 2016 and enrolled 1422 women aged 30-75 years, including 506 women with breast cancer (cases) and 916 women without breast cancer (controls). We developed the BCS chart using a multiple logistic regression analysis. We combined the risks of breast cancer to predict the individual risk of breast cancer. Then, we stratified and colored the predicted risk probabilities as follows: green), 05-09% (yellow), 10-14% (orange), 15-19% (red), 20-24% (brown) and ≥25% (black). The BCS chart provides the risk probability of breast cancer, based on age, body mass index, late menopause, having a benign breast disease and a positive family history of breast cancer among the first-degree or the second/third-degree relatives. According to this chart, an individual can be classified in a category of low risk (green), medium risk (yellow and orange), high risk (red and brown) and very high risk (black) for breast cancer. This chart is a flexible and easy to use tool that can detect high-risk subjects and make the screening program more efficient and productive. © The Author 2017. Published by Oxford University Press on behalf of Faculty of Public Health. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com

  1. News media coverage of a women's health contraversy: how newspapers and TV outlets covered a recent debate over screening mammography.

    Science.gov (United States)

    Steele, Whitney Randolph; Mebane, Felicia; Viswanath, K; Solomon, Janice

    2005-01-01

    Over the past decade, there have been several highly visible debates about mammography that have captured professional, public and media attention. This paper looks at newspaper and television news coverage of a controversial research letter in The Lancet by Gøtzsche and Olsen (2001) that concluded that screening mammography did not prevent deaths from breast cancer. The news pieces examined for this project were published between October 2001 and March 2002 in one of eight U.S. newspapers or aired on one of six national or cable news networks. The six-month period was divided into one-week segments; the numbers of articles published or stories aired in each week were graphed to examine patterns. Each newspaper article and television transcript was then reviewed to identify its main content area and the amount of coverage for each major event was quantified. The highest number of newspaper articles appeared to result from several events during the end of January through the beginning of February. These events included the publication of another meta-analysis of mammography that disputed the original letter's conclusion and a full-page New York Times advertisement paid for by major medical organizations stating their continued support for mammography. The greatest amount of television news coverage was devoted to the announcement of the official federal guidelines by the Secretary of Health and Human Services in late February. We conclude by discussing how the flow of news coverage of medical controversies can potentially impact the actions and reactions of the public, the medical community and health policy makers.

  2. Breast cancer screening controversies: who, when, why, and how?

    Science.gov (United States)

    Chetlen, Alison; Mack, Julie; Chan, Tiffany

    2016-01-01

    Mammographic screening is effective in reducing mortality from breast cancer. The issue is not whether mammography is effective, but whether the false positive rate and false negative rates can be reduced. This review will discuss controversies including the reduction in breast cancer mortality, overdiagnosis, the ideal screening candidate, and the optimal imaging modality for breast cancer screening. The article will compare and contrast screening mammography, tomosynthesis, whole-breast screening ultrasound, magnetic resonance imaging, and molecular breast imaging. Though supplemental imaging modalities are being utilized to improve breast cancer diagnosis, mammography still remains the gold standard for breast cancer screening. Copyright © 2015 Elsevier Inc. All rights reserved.

  3. Does digital mammography suppose an advance in early diagnosis? Trends in performance indicators 6 years after digitalization.

    Science.gov (United States)

    Sala, Maria; Domingo, Laia; Macià, Francesc; Comas, Mercè; Burón, Andrea; Castells, Xavier

    2015-03-01

    To provide a complete evaluation of the long-term impact of full-field digital mammography (FFDM) on the improvement of early diagnosis in a population-based screening program. We included 82,961 screen-film mammograms (SFM) and 79,031 FFDM from women aged 50-69 screened biennially from 1995-2010 in Spain and followed-up to 2012. The first screening round of the program was excluded. Rates of cancer detection, interval cancer, tumoral characteristics and other quality indicators were compared between SFM and FFDM periods using the Chi-square test. Multivariate logistic regression models were fitted. Detection of ductal carcinoma in situ (DCIS) significantly increased with FFDM (0.05 % vs 0.09 %; p = 0.010), along with the proportion of small invasive cancers (Digitalization has supposed an improvement in early diagnosis because DCIS and small invasive cancers increased without a change in detection rate. Moreover, false-positive reduction without an increase in the interval cancer rate was confirmed.

  4. Reconsidering inequalities in preventive health care: an application of cultural health capital theory and the life-course perspective to the take-up of mammography screening.

    Science.gov (United States)

    Missinne, Sarah; Neels, Karel; Bracke, Piet

    2014-11-01

    While there are abundant descriptions of socioeconomic inequalities in preventive health care, knowledge about the true mechanisms is still lacking. Recently, the role of cultural health capital in preventive health-care inequalities has been discussed theoretically. Given substantial analogies, we explore how our understanding of cultural health capital and preventive health-care inequalities can be advanced by applying the theoretical principles and methodology of the life-course perspective. By means of event history analysis and retrospective data from the Survey of Health Ageing and Retirement, we examine the role of cultural capital and cultural health capital during childhood on the timely initiation of mammography screening in Belgium (N = 1348). In line with cumulative disadvantage theory, the results show that childhood cultural conditions are independently associated with mammography screening, even after childhood and adulthood socioeconomic position and health are controlled for. Lingering effects from childhood are suggested by the accumulation of cultural health capital that starts early in life. Inequalities in the take-up of screening are manifested as a lower probability of ever having a mammogram, rather than in the late initiation of screening. © 2014 The Authors. Sociology of Health & Illness © 2014 Foundation for the Sociology of Health & Illness/John Wiley & Sons Ltd.

  5. Comparison of film/screen and PCR digital lateral cervical spine radiographs

    International Nuclear Information System (INIS)

    Silver, D.I.; Kreipke, D.L.; Tarver, R.; Braunstein, E.M.

    1988-01-01

    The authors compared film/screen and Phillips computed radiography (PCR) radiographs of the cervical spine. In 109 patients. fiilm/screen and digital radiographs were compared for adequate visualization (readability) of bone, soft tissue, and trachea. The lowest cervical vertebra seen was noted in each case. The radiographs were interpreted by four radiologists, and both interobserver and intraobserver consistency were measured. Of the PCR radiographs, 97% were readable with a viewbox alone. Of the film/screen radiographs, 9% were readable with a viewbox. With a hotlight, 83% of the film/screen radiographs became readable. Bone, soft tissue, and trachea were better seen on PCR radiographs than on film/screen radiographs (P<.001). There was less interobserver variation on digital radiographs. Readability of cervical spine radiographs was significantly improved with PCR

  6. Validation of the English and Spanish Mammography Beliefs and Attitudes Questionnaire.

    Science.gov (United States)

    Lopez-McKee, Gloria; Bader, Julia

    2011-03-21

    Breast cancer is the leading cause of cancer deaths among Hispanic women in the United States. Unfortunately Hispanic women exhibit poor mammography screening participation, are diagnosed at later stages of the disease, and have lower survival rates than non-Hispanic white women. Several cultural and psycho-social factors have been found to influence mammography screening participation among Hispanic women. We will begin by presenting the theoretical framework that grounded this research program to develop an instrument to assess factors contributing to poor mammography participation among Hispanic women. We will also summarize the early stages in the development of the English and Spanish Mammography Beliefs and Attitudes Questionnaire (MBAQ and SMBAQ) for use with low-health-literacy Mexican-American women. Next we will describe the initial psychometric testing of the MBAQ/SMBAQ, after which we will present the psychometric testing of the SMBAQ with low-health-literacy women. This will be followed by a discussion of the modification of the MBAQ and SMBAQ subscales. We'll conclude with a discussion of the instruments and share our assessment regarding the limitations of this research program, where the program stands to date, and the implications for practice and future research.

  7. Mammography performance in Oman: Review of factors influencing cancer yield and positive predictive value.

    Science.gov (United States)

    Taif, Sawsan; Tufail, Fatma; Alnuaimi, Ahmed Sameer

    2016-06-01

    The aim of this study is to assess mammography performance in Oman by estimating the breast cancer rate and the positive predictive value (PPV) with the influence of some variables. This cross-sectional study was conducted on mammograms done in one of the three main breast imaging centers in Oman between January 2008 and July 2012. Diagnostic and screening groups were identified and assessed separately. Rate of abnormal mammograms, rate of breast cancer and the PPV were estimated according to Breast Imaging Reporting and Data System (BIRADS) score, presence of breast lump and patient's age. Total of 653 mammograms were included, 254 diagnostic and 399 screening. Abnormal mammograms (BIRADS 4 and 5) form 31.9% of the diagnostic examinations compared with 6.8% of screening examinations. Breast cancer was present in 17.9% of the diagnostic compared with 1.0% of the screening group. The PPV of BIRADS 5 was 94.1%, and for BIRADS 4 was 37.1 and 26.7% for diagnostic and screening studies. Overall PPV for abnormal mammograms was 65.2% in the diagnostic and 26.7% in the screening group. Mammography PPV shows positive association with age (P = 0.039) while presence of breast lump has no significant effect on the PPV (P = 0.38). BIRADS 5 score was found to have a high cancer yield making it a strong predictor of cancer. Different results were obtained in the diagnostic compared with screening mammography with higher rates of abnormal mammograms and breast cancer. Mammography performance should be better in the older women. © 2014 Wiley Publishing Asia Pty Ltd.

  8. Diagnostic reference levels in digital mammography: a systematic review

    International Nuclear Information System (INIS)

    Suleiman, Moayyad E.; Brennan, Patrick C.; McEntee, Mark F.

    2015-01-01

    This study aims to review the literature on existing diagnostic reference levels (DRLs) in digital mammography and methodologies for establishing them. To this end, a systematic search through Medline, Cinahl, Web of Science, Scopus and Google scholar was conducted using search terms extracted from three terms: DRLs, digital mammography and breast screen. The search resulted in 1539 articles of which 22 were included after a screening process. Relevant data from the included studies were summarised and analysed. Differences were found in the methods utilised to establish DRLs including test subjects types, protocols followed, conversion factors employed, breast compressed thicknesses and percentile values adopted. These differences complicate comparison of DRLs among countries; hence, an internationally accepted protocol would be valuable so that international comparisons can be made. (authors)

  9. Teaching syllabus for radiological aspects of breast cancer screening with digital mammography

    International Nuclear Information System (INIS)

    Van Ongeval, C.; Van Steen, A.; Bosmans, H.

    2008-01-01

    The purpose of this study is to discuss the content of our new accreditation programme for radiologists' reading digital mammograms in a screening setting and to report our first experience with the new course. The course consisted of a theoretical part, given by the medical physicist, and a practical part given by the radiologist. The practical session is closely linked with the theoretical part and a reading session. The material is fully digital and can be presented on different platforms. In practice, the need for parallel soft-copy reading sessions on high-end workstations limits the number of participants. A high level of interactivity was noted between teacher and participant, with a thorough discussion of different digital mammography systems during a single teaching course. The main challenge for the teacher turned out to be the collection of representative material and the continuous updating of the material: new systems, processing techniques and artefacts need to be included regularly. (authors)

  10. High-contrast resolution of film-screen systems in oral and maxillofacial radiology

    International Nuclear Information System (INIS)

    Kaeppler, G.; Reinert, S.

    2007-01-01

    Purpose: The aim was to determine differences in high-contrast resolution of film-screen systems used in dental panoramic and cephalometric radiography by calculating the modulation transfer function (MTF). The radiographs used to determine the MTF should be taken by the same X-ray units as those used for patient radiographs. Materials and methods: The MTF was determined using a lead grid and according to DIN 6867 - 2 for 11 film-screen systems (speed 250, speed class 200 and 400) used in dental radiographic diagnostics. The optical density was measured using a microdensitometer developed by PTB. Results: With 10% of the modulation transfer factor, newly developed film-screen systems (speed class 200 and 400) demonstrated a resolution of 4.9 to 6 line pairs per mm (panoramic radiography). In cephalometric radiography a film-screen system (speed class 400 and green-sensitive film) had a resolution of 4.2 line pairs per mm and surpassed two film-screen systems (speed class 400, resolution of 3 line pairs per mm, blue-sensitive films). (orig.)

  11. Dual-Energy Contrast-Enhanced Spectral Mammography: Enhancement Analysis on BI-RADS 4 Non-Mass Microcalcifications in Screened Women.

    Directory of Open Access Journals (Sweden)

    Yun-Chung Cheung

    Full Text Available Mammography screening is a cost-efficient modality with high sensitivity for detecting impalpable cancer with microcalcifications, and results in reduced mortality rates. However, the probability of finding microcalcifications without associated cancerous masses varies. We retrospectively evaluated the diagnosis and cancer probability of the non-mass screened microcalcifications by dual-energy contrast-enhanced spectral mammography (DE-CESM.With ethical approval from our hospital, we enrolled the cases of DE-CESM for analysis under the following inclusion criteria: (1 referrals due to screened BI-RADS 4 microcalcifications; (2 having DE-CESM prior to stereotactic biopsy; (3 no associated mass found by sonography and physical examination; and (4 pathology-based diagnosis using stereotactic vacuum-assisted breast biopsy. We analyzed the added value of post-contrast enhancement on DE-CESM.A total of 94 biopsed lesions were available for analysis in our 87 women, yielding 27 cancers [19 ductal carcinoma in situ (DCIS, and 8 invasive ductal carcinoma (IDC], 32 pre-malignant and 35 benign lesions. Of these 94 lesions, 33 showed associated enhancement in DE-CESM while the other 61 did not. All 8 IDC (100% and 16 of 19 DCIS (84.21% showed enhancement, but the other 3 DCIS (15.79% did not. Overall sensitivity, specificity, positive predictive value, negative predictive value and accuracy were 88.89%, 86.56%, 72.72%, 95.08% and 87.24%, respectively. The performances of DE-CESM on both amorphous and pleomorphic microcalcifications were satisfactory (AUC 0.8 and 0.92, respectively. The pleomorphous microcalcifications with enhancement showed higher positive predictive value (90.00% vs 46.15%, p = 0.013 and higher cancer probability than the amorphous microcalcifications (46.3% VS 15.1%. The Odds Ratio was 4.85 (95% CI: 1.84-12.82.DE-CESM might provide added value in assessing the non-mass screened breast microcalcification, with enhancement favorable to the

  12. Dual-Energy Contrast-Enhanced Spectral Mammography: Enhancement Analysis on BI-RADS 4 Non-Mass Microcalcifications in Screened Women.

    Science.gov (United States)

    Cheung, Yun-Chung; Juan, Yu-Hsiang; Lin, Yu-Ching; Lo, Yung-Feng; Tsai, Hsiu-Pei; Ueng, Shir-Hwa; Chen, Shin-Cheh

    2016-01-01

    Mammography screening is a cost-efficient modality with high sensitivity for detecting impalpable cancer with microcalcifications, and results in reduced mortality rates. However, the probability of finding microcalcifications without associated cancerous masses varies. We retrospectively evaluated the diagnosis and cancer probability of the non-mass screened microcalcifications by dual-energy contrast-enhanced spectral mammography (DE-CESM). With ethical approval from our hospital, we enrolled the cases of DE-CESM for analysis under the following inclusion criteria: (1) referrals due to screened BI-RADS 4 microcalcifications; (2) having DE-CESM prior to stereotactic biopsy; (3) no associated mass found by sonography and physical examination; and (4) pathology-based diagnosis using stereotactic vacuum-assisted breast biopsy. We analyzed the added value of post-contrast enhancement on DE-CESM. A total of 94 biopsed lesions were available for analysis in our 87 women, yielding 27 cancers [19 ductal carcinoma in situ (DCIS), and 8 invasive ductal carcinoma (IDC)], 32 pre-malignant and 35 benign lesions. Of these 94 lesions, 33 showed associated enhancement in DE-CESM while the other 61 did not. All 8 IDC (100%) and 16 of 19 DCIS (84.21%) showed enhancement, but the other 3 DCIS (15.79%) did not. Overall sensitivity, specificity, positive predictive value, negative predictive value and accuracy were 88.89%, 86.56%, 72.72%, 95.08% and 87.24%, respectively. The performances of DE-CESM on both amorphous and pleomorphic microcalcifications were satisfactory (AUC 0.8 and 0.92, respectively). The pleomorphous microcalcifications with enhancement showed higher positive predictive value (90.00% vs 46.15%, p = 0.013) and higher cancer probability than the amorphous microcalcifications (46.3% VS 15.1%). The Odds Ratio was 4.85 (95% CI: 1.84-12.82). DE-CESM might provide added value in assessing the non-mass screened breast microcalcification, with enhancement favorable to the

  13. Variations in screening outcome among pairs of screening radiologists at non-blinded double reading of screening mammograms: a population-based study

    NARCIS (Netherlands)

    Klompenhouwer, E. G.; Duijm, L. E. M.; Voogd, A. C.; den Heeten, G. J.; Nederend, J.; Jansen, F. H.; Broeders, M. J. M.

    2014-01-01

    Substantial inter-observer variability in screening mammography interpretation has been reported at single reading. However, screening results of pairs of screening radiologists have not yet been published. We determined variations in screening performances among pairs of screening radiologists at

  14. Cultural views, language ability, and mammography use in Chinese American women.

    Science.gov (United States)

    Liang, Wenchi; Wang, Judy; Chen, Mei-Yuh; Feng, Shibao; Yi, Bin; Mandelblatt, Jeanne S

    2009-12-01

    Mammography screening rates among Chinese American women have been reported to be low. This study examines whether and how culture views and language ability influence mammography adherence in this mostly immigrant population. Asymptomatic Chinese American women (n = 466) aged 50 and older, recruited from the Washington, D.C. area, completed a telephone interview. Regular mammography was defined as having two mammograms at age-appropriate recommended intervals. Cultural views were assessed by 30 items, and language ability measured women's ability in reading, writing, speaking, and listening to English. After controlling for risk perception, worry, physician recommendation, family encouragement, and access barriers, women holding a more Chinese/Eastern cultural view were significantly less likely to have had regular mammograms than those having a Western cultural view. English ability was positively associated with mammography adherence. The authors' results imply that culturally sensitive and language-appropriate educational interventions are likely to improve mammography adherence in this population.

  15. The efficacy of using computer-aided detection (CAD) for detection of breast cancer in mammography screening

    DEFF Research Database (Denmark)

    Henriksen, Emilie L; Carlsen, Jonathan F; Vejborg, Ilse Mm

    2018-01-01

    Background Early detection of breast cancer (BC) is crucial in lowering the mortality. Purpose To present an overview of studies concerning computer-aided detection (CAD) in screening mammography for early detection of BC and compare diagnostic accuracy and recall rates (RR) of single reading (SR......) with SR + CAD and double reading (DR) with SR + CAD. Material and Methods PRISMA guidelines were used as a review protocol. Articles on clinical trials concerning CAD for detection of BC in a screening population were included. The literature search resulted in 1522 records. A total of 1491 records were...... excluded by abstract and 18 were excluded by full text reading. A total of 13 articles were included. Results All but two studies from the SR vs. SR + CAD group showed an increased sensitivity and/or cancer detection rate (CDR) when adding CAD. The DR vs. SR + CAD group showed no significant differences...

  16. Experience with the european quality assurance guidelines for digital mammography systems in a national screening programme

    International Nuclear Information System (INIS)

    McCullagh, J.; Keavey, E.; Egan, G.; Phelan, N.

    2013-01-01

    The transition to a fully digital breast screening programme, utilising three different full-field digital mammography (FFDM) systems has presented many challenges to the implementation of the European guidelines for physico-technical quality assurance (QA) testing. An analysis of the QA results collected from the FFDM systems in the screening programme over a 2-y period indicates that the three different systems have similar QA performances. Generally, the same tests were failed by all systems and failure rates were low. The findings provide some assurance that the QA guidelines are being correctly implemented. They also suggest that there is more scope for the development of the relevance of the guidelines with respect to modern FFDM systems. This study has also shown that a summary review of the QA data can be achieved by simple organisation of the QA data storage and by automation of data query and retrieval using commonly available software. (authors)

  17. Primary breast lymphoma: a consideration in an HIV patient when a mass is discovered by screening mammography: a case report.

    Science.gov (United States)

    Akinwande, Olagoke K; Paley, Robert

    2008-12-11

    Primary Breast lymphoma is a rare lesion that has been reported in patients without HIV. However, Primary Breast lymphoma occurring in a patient with HIV has rarely been reported despite the fact that HIV infection is known to increase the propensity to develop certain types of lymphoma. We report a case of an HIV patient with breast lymphoma that was discovered by screening mammography while presenting our argument for more cautionary management in this patient population.

  18. A study of quality assurance in mammography

    International Nuclear Information System (INIS)

    Briquet, Claudia; Mota, Helvecio C.; Costa, Marcos R.

    1997-01-01

    Full text. Nowadays mammography has two definitive important roles: as a complementary tool to confirm clinical findings and for the detection of early breast cancer. To reach and maintain the standards of image quality within the frontiers of reasonable radiation doses, the facilities must follow a QA program. The objective of this study is to accomplish such a program in three school hospitals in Rio de Janeiro. We made assessment of clinical images using the Accreditation American Phantom and measured the patients skin entrance doses with TLD 100. In each facility we evaluated the technical parameters of the mammographic units using a Victoreen 4000 M+ and an evaluation of the compression devices. The 3 hospitals studied use film and screen Min R Kodak and have Kodak processors, none of them dedicated to mammograms. The tube voltage, measured was not significantly different from the indicated values, the variations were lesser than 5%. In one of the hospitals the kVp did not show reproducibility, the coefficient of variation was too high - 1,02. The same facility showed an exposure time with variation of 7% and we asked for corrective action. Measures of HVL showed the same value for the 3 hospitals the compression were adequate. The patients skin entrance doses were measured with TLD 100 and showed the range 3,25 a 10,26 mGy. This range is due to differences in density and thickness of the breast. The doses values were in accordance with the Quality Criteria for Mammography of the Commission of the European Communities

  19. Barriers and incentives for choosing to specialise in mammography: Qualitative analysis

    International Nuclear Information System (INIS)

    Warren-Forward, H.M.; Taylor, J.

    2017-01-01

    Aim: There is a projected shortage of radiographers working in breast screening and this study aimed to examine comments from open response questions from a mixed methods survey of current diagnostic radiography students on their perceptions of working in mammography. Method: The survey asked three open ended questions: Justification of choice of modality in which they would want to specialise, why they believed there was a shortage of radiographers working in breast screening and any other comment about mammography. Results: Reasons given for specialising in any modality was interest, feature of a modality, amount of clinical exposure during the degree program, personal issues and career prospects. Few current diagnostic radiography students indicated that they would be interested in specialising in breast imaging. They considered there to be a shortage of radiographers as breast imaging was seen to be repetitive, high pressure, intimate and gender biased. Lack of education, clinical exposure, limited career prospects and low pay were also discussed. Conclusions: Increasing education to the modality during the degree, allowing males to be involved in breast imaging and promoting part-time work in mammography while also working in other modalities may alter the perception that mammography offers a limited career pathway. - Highlights: • Reasons to specialise in a modality include “interest”, “clinical exposure” and “career prospect”. • Reasons not to specialise include “availability of modality” and “gender of radiographer”. • Repetitive nature of mammography was cited as the most common reason for shortage of radiographers. • Restriction to female only radiographers was perceived to be a barrier. • Mammography perceived to be high stress due to pressure on getting correct diagnosis.

  20. Results of a 2011 national questionnaire for investigation of mean glandular dose from mammography in Japan.

    Science.gov (United States)

    Asada, Y; Suzuki, S; Minami, K; Shirakawa, S

    2014-03-01

    Diagnostic reference levels (DRLs) for mammography have yet to be created in Japan. A national questionnaire investigation into radiographic conditions in Japan was carried out for the purpose of creating DRLs. Items investigated included the following: tube voltage; tube current; current-time product; source-image distance; craniocaudal view; automatic exposure control (AEC) settings; name of mammography unit; image receptor system (computed radiography (CR), flat panel detector (FPD), or film/screen (F/S)); and supported or unsupported monitor diagnosis (including monitor resolution). Estimation of the mean glandular dose (MGD) for mammography was performed and compared with previous investigations. The MGD was 1.58(0.48) mGy, which did not significantly differ from a 2007 investigation. In relation to image receptors, although no difference in average MGD values was observed between CR and FPD systems, F/S systems had a significantly decreased value compared to both CR and FPDs. Concerning digital systems (FPDs), the MGD value of the direct conversion system was significantly higher than the indirect conversion system. No significant difference in MGD value was evident concerning type of monitor diagnosis for either the CR or the FPD digital systems; however, hard copies were used more often in CR. No significant difference in the MGD value was found in relation to monitor resolution. This report suggests ways to lower the doses patients undergoing mammography receive in Japan, and serves as reference data for 4.2 cm compressed breast tissue of 50% composition DRLs. Furthermore, our findings suggest that further optimisation of FPD settings can promote a reduction in the MGD value.

  1. Diagnostic Invasiveness and Psychosocial Consequences of False-Positive Mammography

    DEFF Research Database (Denmark)

    Heleno, Bruno M.; Siersma, Volkert Dirk; Brodersen, John

    2015-01-01

    PURPOSE: We undertook a study to assess whether women with false-positivemammography have worse psychosocial consequences if managed with aworkup that involves a biopsy (invasive group) than if managed with only additional imaging (noninvasive group). METHODS: We performed subgroup analysis...... of a cohort study of 454 womenwith abnormal screening mammography and 908 matched control women withnormal results. Using a condition-specific questionnaire (Consequences of Screening in Breast Cancer), we assessed 12 psychosocial consequences at 5 time points (0, 1, 6, 18, and 36 months after final diagnosis......) and compared the 2 groups of women with false-positives (invasive and noninvasive management groups). RESULTS: Among the 252 women with false-positive mammography eligible forthis study, psychosocial consequences were similar for those managed invasivelyand those managed noninvasively during the 36 months...

  2. Ultrasound as a secondary screening tool in mammographically dense breasts

    International Nuclear Information System (INIS)

    Griggs, Kylie

    2006-01-01

    It is well known that breast screening is a part of our society and is designed to reduce the mortality and morbidity from breast cancer. Mammography is the imaging modality of choice in a breast-screening environment. Both the detection rate of mammography in a screening environment and the sensitivity of mammography in symptomatic women are known to be greater than that of ultrasound. However, after a review of literature both of these are said to increase when the two imaging modalities are combined. This paper will present that mammography has limitations in breast imaging, especially in women with dense breasts and that ultrasound can have a benefit as a secondary screening tool in these women. It will be shown that although ultrasound also has its limitations, these can be minimised with the implementation of effective education and imaging protocols. The paper will conclude that although further research into ultrasound as screening tool is required, its use as a complement to mammography can only be of benefit to the general population

  3. Computed tomographic mammography using a conventional body scanner.

    Science.gov (United States)

    Chang, C H; Nesbit, D E; Fisher, D R; Fritz, S L; Dwyer, S J; Templeton, A W; Lin, F; Jewell, W R

    1982-03-01

    The technique for computed tomographic (CT) examination of the breasts using a conventional body scanner is described, and experience with 67 patients is reported. In the diagnosis of both malignant and benign breast lesions, the results with a body scanner were equal to those of a dedicated CT/M mammographic unit. Although the CT study of the breast cannot replace conventional mammography in screening or in routine diagnostic workup, the unique capability of demonstrating both anatomic changes and increased iodide concentration in a cancer provides many advantages over conventional mammography. CT mammography appears to have the capability to detect breast cancers that are occult to other methods. Indications for a CT study of the breasts are: (1) clinically suspected breast cancer, especially with a mammographically occult lesion; (2) questionable mammographic findings, including microcalcifications, tumor shape, architectural distortion, and uncertain lesion location; and (3) evaluation of postbiopsy or postlumpectomy breast cancers when a primary irradiation therapy is contemplated. Breast CT also appears to be a valuable diagnostic tool in searching for a second primary breast cancer, follow-up study of postirradiation of breast cancer, followup study for postmastectomy patients, and screening procedure for genetically high-risk patients, especially those with dense breasts.

  4. Estimation of breast percent density in raw and processed full field digital mammography images via adaptive fuzzy c-means clustering and support vector machine segmentation

    International Nuclear Information System (INIS)

    Keller, Brad M.; Nathan, Diane L.; Wang Yan; Zheng Yuanjie; Gee, James C.; Conant, Emily F.; Kontos, Despina

    2012-01-01

    Purpose: The amount of fibroglandular tissue content in the breast as estimated mammographically, commonly referred to as breast percent density (PD%), is one of the most significant risk factors for developing breast cancer. Approaches to quantify breast density commonly focus on either semiautomated methods or visual assessment, both of which are highly subjective. Furthermore, most studies published to date investigating computer-aided assessment of breast PD% have been performed using digitized screen-film mammograms, while digital mammography is increasingly replacing screen-film mammography in breast cancer screening protocols. Digital mammography imaging generates two types of images for analysis, raw (i.e., “FOR PROCESSING”) and vendor postprocessed (i.e., “FOR PRESENTATION”), of which postprocessed images are commonly used in clinical practice. Development of an algorithm which effectively estimates breast PD% in both raw and postprocessed digital mammography images would be beneficial in terms of direct clinical application and retrospective analysis. Methods: This work proposes a new algorithm for fully automated quantification of breast PD% based on adaptive multiclass fuzzy c-means (FCM) clustering and support vector machine (SVM) classification, optimized for the imaging characteristics of both raw and processed digital mammography images as well as for individual patient and image characteristics. Our algorithm first delineates the breast region within the mammogram via an automated thresholding scheme to identify background air followed by a straight line Hough transform to extract the pectoral muscle region. The algorithm then applies adaptive FCM clustering based on an optimal number of clusters derived from image properties of the specific mammogram to subdivide the breast into regions of similar gray-level intensity. Finally, a SVM classifier is trained to identify which clusters within the breast tissue are likely fibroglandular, which

  5. Barriers and incentives for choosing to specialise in mammography: Qualitative analysis.

    Science.gov (United States)

    Warren-Forward, H M; Taylor, J

    2017-02-01

    There is a projected shortage of radiographers working in breast screening and this study aimed to examine comments from open response questions from a mixed methods survey of current diagnostic radiography students on their perceptions of working in mammography. The survey asked three open ended questions: Justification of choice of modality in which they would want to specialise, why they believed there was a shortage of radiographers working in breast screening and any other comment about mammography. Reasons given for specialising in any modality was interest, feature of a modality, amount of clinical exposure during the degree program, personal issues and career prospects. Few current diagnostic radiography students indicated that they would be interested in specialising in breast imaging. They considered there to be a shortage of radiographers as breast imaging was seen to be repetitive, high pressure, intimate and gender biased. Lack of education, clinical exposure, limited career prospects and low pay were also discussed. Increasing education to the modality during the degree, allowing males to be involved in breast imaging and promoting part-time work in mammography while also working in other modalities may alter the perception that mammography offers a limited career pathway. Crown Copyright © 2016. Published by Elsevier Ltd. All rights reserved.

  6. Breast cancer imaging: Mammography among women of up to 45 years

    International Nuclear Information System (INIS)

    Schnejder-Wilk, A.

    2010-01-01

    Background: Among women under the age of 40, screening mammography examinations are not performed routinely. An ultrasonography scan is considered to be a basic breast imaging examination among younger women. The purpose of this study was to analyze mammography images, as well as to evaluate the usefulness and role of mammography in breast cancer diagnostic processes in women of up to 45 years, based on own experience. Material/Methods: A retrospective analysis of mammography images, including 144 cases of breast cancer diagnosed in the group of 140 women of 45 years of age. All the patients underwent pre-treatment mammography and surgery procedure. The images were evaluated in accordance to BIRADS criteria. Lesions detectable in mammography were grouped as follows: spiculated mass; nonmicrocalcified oval/round mass; microcalcified mass (regardless of shape); microcalcifications; architectural distortion; breast tissue asymmetry. Results: The most common mammographic symptom was solid tumor (41%), followed by microcalcified tumors (20.8%). Clusters of microcalcifications constituted 17.4% of mammography findings. In 4.9% of mammography scans, examination did not reveal any pathological lesions. Conclusions: Breast cancer mammograms of women aged up to 45 years do not differ from diagnostic pictures of breast cancer in older women. The diagnostic appearance of breast cancer in 1/3 of the patients involved microcalcifications detectable only on mammograms. All the women with suspicion of breast cancer should have their mammography examinations performed, irrespective of ultrasonography scans. (author)

  7. Optimal breast cancer screening strategies for older women: current perspectives

    Directory of Open Access Journals (Sweden)

    Braithwaite D

    2016-02-01

    Full Text Available Dejana Braithwaite,1 Joshua Demb,1 Louise M Henderson2 1Department of Epidemiology and Biostatistics, University of California, San Francisco, CA, 2Department of Radiology, University of North Carolina, Chapel Hill, NC, USA Abstract: Breast cancer is a major cause of cancer-related deaths among older women, aged 65 years or older. Screening mammography has been shown to be effective in reducing breast cancer mortality in women aged 50–74 years but not among those aged 75 years or older. Given the large heterogeneity in comorbidity status and life expectancy among older women, controversy remains over screening mammography in this population. Diminished life expectancy with aging may decrease the potential screening benefit and increase the risk of harms. In this review, we summarize the evidence on screening mammography utilization, performance, and outcomes and highlight evidence gaps. Optimizing the screening strategy will involve separating older women who will benefit from screening from those who will not benefit by using information on comorbidity status and life expectancy. This review has identified areas related to screening mammography in older women that warrant additional research, including the need to evaluate emerging screening technologies, such as tomosynthesis among older women and precision cancer screening. In the absence of randomized controlled trials, the benefits and harms of continued screening mammography in older women need to be estimated using both population-based cohort data and simulation models. Keywords: aging, breast cancer, precision cancer screening

  8. The impact of age on the art of mammography and how to adapt accordingly.

    Science.gov (United States)

    Lake, B; Cielecki, L; Williams, S; Worrall, C; Metelko, M

    2017-11-01

    Breast cancer is increasingly a disease of the elderly, and combined with the NHS Breast Screening Extension means that more elderly patients are having mammography. Increasing age can make mammography more technically difficult. This is a technical note detailing the results of a local audit which may be of interest due to potential service implications. A retrospective audit of the first year of screening extension of The Shropshire Breast Screening Programme. Aims to collect data on patient demographics and describe the technical adaptations developed in Shropshire. Breast screening extension has increased by 2.5 times the number of women aged 70-74 screened, and doubled the overall numbers of women over 70 screened. Significantly more older patients are being screened to present technical challenges to a screening programme. Data was obtained from a month of screening showed that 29% of patients over 70 needed extra time for positioning. Reasons included 22% difficulty in obtaining adequate positioning and 15% needed a relative to aid with consent. In the Shropshire screening programme different technical adaptations have been developed and are key to ensuring adequate images. These include double appointments, two radiographers, thorough assessment, steeper angles, seated examinations, from-below imaging and pre-planning for subsequent screen. Significantly more older women are having breast screening due to the increasing incidence of breast cancer and the Breast Screening Programme extension. Increasing age can significantly increase time taken for adequate imaging and present technical challenges. Development of technical adaptations to art of mammography is key to achieve adequate images. Copyright © 2017 The College of Radiographers. Published by Elsevier Ltd. All rights reserved.

  9. Contrast-enhanced Spectral Mammography: Technique, Indications, and Clinical Applications.

    Science.gov (United States)

    Bhimani, Chandni; Matta, Danielle; Roth, Robyn G; Liao, Lydia; Tinney, Elizabeth; Brill, Kristin; Germaine, Pauline

    2017-01-01

    Contrast-enhanced spectral mammography (CESM) combines the benefits of full field digital mammography with the concept of tumor angiogenesis. Technique and practical applications of CESM are discussed. An overview of the technique is followed by a demonstration of practical applications of CESM in our practice. We have successfully implemented CESM into our practice as a screening, diagnostic, staging, and treatment response tool. It is important to understand the technique of CESM and how to incorporate it into practice. Copyright © 2017 The Association of University Radiologists. Published by Elsevier Inc. All rights reserved.

  10. Breast cancer screening with digital breast tomosynthesis.

    Science.gov (United States)

    Skaane, Per

    2017-01-01

    To give an overview of studies comparing full-field digital mammography (FFDM) and digital breast tomosynthesis (DBT) in breast cancer screening. The implementation of tomosynthesis in breast imaging is rapidly increasing world-wide. Experimental clinical studies of relevance for DBT screening have shown that tomosynthesis might have a great potential in breast cancer screening, although most of these retrospective reading studies are based on small populations, so that final conclusions are difficult to draw from individual reports. Several retrospective studies and three prospective trials on tomosynthesis in breast cancer screening have been published so far, confirming the great potential of DBT in mammography screening. The main results of these screening studies are presented. The retrospective screening studies from USA have all shown a significant decrease in the recall rate using DBT as adjunct to mammography. Most of these studies have also shown an increase in the cancer detection rate, and the non-significant results in some studies might be explained by a lack of statistical power. All the three prospective European trials have shown a significant increase in the cancer detection rate. The retrospective and the prospective screening studies comparing FFDM and DBT have all demonstrated that tomosynthesis has a great potential for improving breast cancer screening. DBT should be regarded as a better mammogram that could improve or overcome limitations of the conventional mammography, and tomosynthesis might be considered as the new technique in the next future of breast cancer screening.

  11. Basic elements for breast screening programs for Rwanda

    International Nuclear Information System (INIS)

    Abenanye, Emmanuel

    2015-02-01

    Mammography refers to the X-ray examination of the human breast, and is considered the single most important diagnostic tool in the early detection of breast cancer, which is by far the most common cancer among women. There is good evidence from clinical trials, that mammographic screening can reduce the breast cancer mortality with about 30%. The side effects include a small and age related risk of carcinogenesis due to the exposure of the glandular tissues in the breast to ionizing radiation. As for all X-ray examinations, and of special importance when investigating large populations of asymptomatic women, the relationship between radiation risk and diagnostic accuracy in mammography must be optimized. The overall objective of this thesis was to investigate and improve methods for average glandular dose (AGD) and image quality evaluation in mammography and provide some practical guidance. To assess the behavioral factors influencing breast screening the best set up of the mammography unit as well as equipment construction and the skills of people operating the machines in terms of the radiation protection screening programs. There has been doubts about the efficiency of so called service screening, i.e. routine screening programs (Sjonell and Stahle, 1999), but there is evidence suggesting a reduction of breast cancer mortality similar to that observed in the randomised trials (Duffy et al. 2002). However no study has been carried out in Rwanda of this nature to see what are the basic breast screening elements and behavioral elements that influence it. Therefore, the factors that influence women's mammography screening behavior is an important issue to be uncovered, in order to facilitate the understanding of such a behavior. This report sets out to investigate the factors that influence participation in mammography screening in Rwanda. Such an investigation aims to raise the awareness of health care providers of the factors that influence Rwanda's women

  12. Early identification of iflammantory rheumatic bone disease via mammography technique

    International Nuclear Information System (INIS)

    Singer, F.; Jakic, L.

    1981-01-01

    A decisive improvement of early X-ray diagnosis of inflammatory rheumatic osseus changes becomes possible by means of an appropriate combination of film and foil of the type which has been in use in mammography for a long time. (orig.) [de

  13. The relative and absolute speed of radiographic screen - film systems

    International Nuclear Information System (INIS)

    Lee, In Ja; Huh, Joon

    1993-01-01

    Recently, a large number of new screen-film systems have become available for use in diagnostic radiology. These new screens are made of materials generally known as rare - earth phosphors which have high x-ray absorption and high x-ray to light conversion efficiency compared to calcium tungstate phosphors. The major advantage of these new systems is reduction of patient exposure due to their high speed or high sensitivity. However, a system with excessively high speed can result in a significant degradation of radiographic image quality. Therefore, the speed is important parameters for users of these system. Our aim of in this was to determine accurately and precisely the absolute speed and relative speeds of both new and conventional screen - film system. We determined the absolute speed in condition of BRH phantom beam quality and the relative speed were measured by a split - screen technique in condition of BRH and ANSI phantom beam quality. The absolute and the relative speed were determined for 8 kinds of screen - 4 kinds of film in regular system and 7 kinds pf screen - 7 kinds of film in ortho system. In this study we could know the New Rx, T - MAT G has the highest film speed, also know Green system's standard deviation of relative speed larger than blue system. It was realized that there were no relationship between the absolute speed and the blue system. It was realized that there were no relationship between the absolute speed and the relative speed in ortho or regular system

  14. Evaluation of a mass screening of breast cancer with mammography in personnel of regional public schools

    International Nuclear Information System (INIS)

    Saito, Yoshihiro; Muto, Taisei; Asanuma, Taku; Horikoshi, Akira; Tsuchihara, Katsuo

    2009-01-01

    We have examined a total of 15,224 women in our hospital aiming at a mass screening of breast cancer with mammography (MMG) during the last 8 years. Subjected women were teachers or staffs of public schools in six prefectures in the Tohoku area. More than 90% of them were under 50 years old and women younger than 49 accounted for about half of them. A recall rate was 3.8%, and breast cancer was found in 55 women (0.36%) and the ratio of cancers diagnosed among recalled women was 9.5%. Twenty-one point eight percent of detected cancers were associated with calcification. The average diameter of the detected tumors in the screening group was 1.6 cm, whereas that of outpatients (controls) was 2.5 cm. Stage 0 and I cancer cases in the screening group accounted for 82.0%, whereas those in the outpatient group, 49.6%, indicating a significant increase in detection rate of early breast cancer in the screening compared to the outpatients group. However, detection rate of breast masses was 76.7% of all cases of breast tumor by means of MMG, versus 86.0% by means of physical examination. These results suggest that the mass screening by using physical examination and MMG, as well as ultrasonography, may provide a better clinical application for precise diagnosis, when it is done for working women in the regional public schools who are younger. (author)

  15. [Hierarchy structuring for mammography technique by interpretive structural modeling method].

    Science.gov (United States)

    Kudo, Nozomi; Kurowarabi, Kunio; Terashita, Takayoshi; Nishimoto, Naoki; Ogasawara, Katsuhiko

    2009-10-20

    Participation in screening mammography is currently desired in Japan because of the increase in breast cancer morbidity. However, the pain and discomfort of mammography is recognized as a significant deterrent for women considering this examination. Thus quick procedures, sufficient experience, and advanced skills are required for radiologic technologists. The aim of this study was to make the point of imaging techniques explicit and to help understand the complicated procedure. We interviewed 3 technologists who were highly skilled in mammography, and 14 factors were retrieved by using brainstorming and the KJ method. We then applied Interpretive Structural Modeling (ISM) to the factors and developed a hierarchical concept structure. The result showed a six-layer hierarchy whose top node was explanation of the entire procedure on mammography. Male technologists were related to as a negative factor. Factors concerned with explanation were at the upper node. We gave attention to X-ray techniques and considerations. The findings will help beginners improve their skills.

  16. Screen-printed piezoceramic thick films for miniaturised devices

    DEFF Research Database (Denmark)

    Lou-Moeller, R.; Hindrichsen, Christian Carstensen; Thamdrup, Lasse Højlund

    2007-01-01

    machining. On the other hand, the process of screen printing thick films involves potential problems of thermal matching and chemical compatibility at the processing temperatures between the functional film, the substrate and the electrodes. As an example of such a miniaturised device, a MEMS accelerometer...

  17. Specialized software for optimization of the quality control of the mammography units

    International Nuclear Information System (INIS)

    Stoeva, M.; Vassileva, J.

    2004-01-01

    Quality control is essential to ensure the equipment used is reliable and consistent in order to maintain radiation does as low as reasonably achievable whilst optimizing image quality and performance in mammography. The effectiveness of mammographic screening is highly dependent on the consistent production of high quality diagnostic images. Mammography is highly dependent on the equipment status, which requires an effective Quality Control (QC) program to provide tools for continuous assessment of the equipment performance and also data storage and analysis of the protocols' data. The objective of this paper is to present the specialized software for Quality Control of the Mammography Units, as tool providing additional functionality for optimizations of the Mammography QC data storage and management. The PC program was developed according to the requirements stated in the European protocol for Quality Control of the Mammography Screening and the data collected as a result of its application in several Bulgarian hospitals. The Structured Analysis method was used in order to perform a case, which resulted in the development of the specialized software with a database module, providing the following functionality: Data Storage, Preliminary Data Processing and Post-Processing, Manual Data Entry, Data Import from XLS format, Data Export to XLS format, Printing, Data Filters, Automated Calculation, Automated Graphical Representation, Archiving The development of specialized QC software with a database for mammography units facilitates the process of QC data storage and handling and minimizes the errors. The electronic format for data storage is especially useful in case of long-term storage and periodical data analysis/access. The integrated data processing functionality and the automated import/export features based on standard platform increase the compatibility of the data. (authors)

  18. A comparison of mean glandular dose diagnostic reference levels within the all-digital irish national breast screening programme and the Irish symptomatic breast services

    International Nuclear Information System (INIS)

    O'Leary, D.; Rainford, L.

    2013-01-01

    Data on image quality, compression and radiation dose were collected from symptomatic breast units within the Republic of Ireland. Quantitative and qualitative data were analysed using SPSS. Recommendations of mean glandular dose (MGD) diagnostic reference levels were made at various levels for film-screen and full field digital mammography units to match levels published worldwide. MGDs received by symptomatic breast patients within Ireland are higher than those received in the all-digital Irish Breast Screening service; 55-65 mm breast: 1.75 mGy (screening) vs. 2.4 mGy (symptomatic) at the 95. percentile; various reasons are proposed for the differences. MGDs achieved in the screening service may be lower because of the exacting requirements for radiographer training, characteristics of the patients and equipment quality assurance levels. More precise imaging guidelines, standards and training of symptomatic radiographers performing mammography are suggested to remediate MGDs delivered to the breasts of Irish women attending the symptomatic breast services. (authors)

  19. Mammography: Technique and diagnostic accuracy

    International Nuclear Information System (INIS)

    Kim, Chung Ja; Bahk, Yong Whee; Lee, Don Young

    1974-01-01

    Mammography is now in world wide use, But this has received rather scanty attention in Korea. The purposes of the present communication are twofold: (1) Detailing of technical and photographic aspects of mam in ography and (2) an assessment of its diagnostic accuracy as experienced by us. The clinical materials consisted of 88 cases of mammography performed at the Department of Radiology, St. Mary's Hospital, Catholic Medical College during the 2 years-period from April 1972. We used nonscreen type mammographic or industrial fine- grain films, and a special mammographic device that can be attached to any of the ordinary radiographic machine. Technical factors are shown in Table II. Of 88 cases 19 were operated on or biopsied. There were 7 cases of carcinoma. 8 cases of inflammatory diseases, and 4 cases of benign tumor. Mammographic diagnosis was correct in 85.7% of carcinoma and 87.5% of inflammatory diseases. One misdiagnosis of 7 cases of carcinoma was turned out to be cystosarcoma phylloides. Of 4 cases of benign tumors 2 were correctly diagnosed, and the other 2 mistaken for either inflammatory disease or simple lactating breast. However, none of the benign conditions were diagnosed as malignant process. We found that nonscreen type mammographic or industrial fine-grain films, and hand-processing were necessary in obtaining the mammograms of desirable quality

  20. Our trial to improve patient positioning during mammography

    International Nuclear Information System (INIS)

    Nakayama, Takashi; Kotsuma, Yoshikazu; Hiramatsu, Sawako

    2007-01-01

    For effective breast cancer screening, reading of high-quality mammograms is essential, and for this purpose proper patient positioning during mammography is important. At our Shin-Osaka Mammography Seminar, which includes eight institutions, a physician and nine radiology technicians get together weekly in order to critically review mammogram reading and techniques for obtaining good mammograms. We have recognized that patient positioning has a great effect on mammogram quality, particularly for women in their 40 s who have dense mammary glands, and we have adopted a digital mammography system, or comparative mammography for such patients. Since July 2005, we have critically reviewed positioning every 3 or 4 months with the aim of improving our technique. Eight institutions have participated in this trial, each contributing mammograms taken recently from 20 to 30 consecutive participants, and the grade of positioning has been determined according to the Institutional Mammogram Estimation Standard (6 items, each scoring a maximum of 4 points, total 24 points) proposed by the Central Committee for Quality Control of Mammography Screening. The estimation has been done by both ourselves and committee members. When a total of 20 points or more is obtained and all 6 items score 3 points or more, it is considered that the positioning has been good, and this is termed ''Positioning A'' (P-A). On the other hand, if the total score is less than 20 points, and any one of the 6 items scores less than 3 points, it is considered that positioning has been inadequate, and this is termed ''Positioning-D'' (P-D). At the first review meeting, which was held before our critical study, P-A accounted for 48% of cases, and this had improved to 72% at the second meeting, and to 66% at the third. P-D accounted for 41% of cases at the first meeting, 20% at the second, and 21% at the third. Thus our trial involving discussion between a physician and technicians to critically review good